WorldWideScience

Sample records for sampling operations pnl

  1. Hemostasis in tubeless PNL: point of technique.

    Science.gov (United States)

    Aron, Monish; Goel, Rajiv; Kesarwani, Pawan K; Gupta, Narmada P

    2004-01-01

    Tubeless PNL (percutaneous nephrolithotomy), in a highly selected group of patients, is a modification aimed at reducing the morbidity of PNL. We present a simple technique of achieving tract hemostasis as an adjunct to the safe performance of a tubeless PNL. Charts of 40 consecutive patients who underwent tubeless PNL at our center were reviewed. In the latter 20 consecutive patients, diathermy coagulation of the intrarenal bleeders and tract was done and these patients were compared with the earlier 20 patients in whom fulguration was not done. Drop in hemoglobin, postoperative analgesic requirement, operating time, length of hospitalization and postoperative complications were compared. No statistical difference was found between the operative times and drop in hemoglobin for both the groups. The length of hospitalization and postoperative analgesic requirement were significantly less in the fulguration group. No significant complications were noted in either of the two groups. Fulguration of visible intrarenal and tract bleeders is a simple, safe and effective hemostatic adjunct in patients undergoing tubeless PNL. copyright 2004 S. Karger AG, Basel

  2. PNL1 and PNL2 : Arabidopsis homologs of maize PAN1

    OpenAIRE

    Clark, Lauren Gail

    2010-01-01

    PNL1 and PNL2 are the closest Arabidopsis relatives of maize pan1. pan1 and the PNL family of 11 genes encode leucine-rich repeat, receptor-like kinases, however none of these putative kinases is predicted to have actual kinase function, due to one or more amino acid substitutions in residues necessary for kinase function. Because PAN1 plays a role in subsidiary cell formation in maize, it is hypothesized that PNL1 and PNL2 are involved in stomatal formation in Arabidopsis. YFP fusions of the...

  3. ALDS 1978 panel review. [PNL

    Energy Technology Data Exchange (ETDEWEB)

    Hall, D.L. (ed.)

    1979-08-01

    Pacific Northwest Laboratory (PNL) is examining the analysis of large data sets (ALDS). After one year's work, a panel was convened to evaluate the project. This document is the permanent record of that panel review. It consists of edited transcripts of presentations made to the panel by the PNL staff, a summary of the responses of the panel to these presentations, and PNL's plans for the development of the ALDS project. The representations of the PNL staff described various aspects of the project and/or the philosophy surrounding the project. Supporting materials appear in appendixes. 20 figures, 4 tables. (RWR)

  4. Correlated sampling added to the specific purpose Monte Carlo code McPNL for neutron lifetime log responses

    International Nuclear Information System (INIS)

    Mickael, M.; Verghese, K.; Gardner, R.P.

    1989-01-01

    The specific purpose neutron lifetime oil well logging simulation code, McPNL, has been rewritten for greater user-friendliness and faster execution. Correlated sampling has been added to the code to enable studies of relative changes in the tool response caused by environmental changes. The absolute responses calculated by the code have been benchmarked against laboratory test pit data. The relative responses from correlated sampling are not directly benchmarked, but they are validated using experimental and theoretical results

  5. PNL technical review of pressurized thermal-shock issues

    International Nuclear Information System (INIS)

    Pedersen, L.T.; Apley, W.J.; Bian, S.H.; Defferding, L.J.; Morgenstern, M.H.; Pelto, P.J.; Simonen, E.P.; Simonen, F.A.; Stevens, D.L.; Taylor, T.T.

    1982-07-01

    Pacific Northwest Laboratory (PNL) was asked to develop and recommend a regulatory position that the Nuclear Regulatory Commission (NRC) should adopt regarding the ability of reactor pressure vessels to withstand the effects of pressurized thermal shock (PTS). Licensees of eight pressurized water reactors provided NRC with estimates of remaining effective full power years before corrective actions would be required to prevent an unsafe operating condition. PNL reviewed these responses and the results of supporting research and concluded that none of the eight reactors would undergo vessel failure from a PTS event before several more years of operation. Operator actions, however, were often required to terminate a PTS event before it deteriorated to the point where failure could occur. Therefore, the near-term (less than one year) recommendation is to upgrade, on a site-specific basis, operational procedures, training, and control room instrumentation. Also, uniform criteria should be developed by NRC for use during future licensee analyses. Finally, it was recommended that NRC upgrade nondestructive inspection techniques used during vessel examinations and become more involved in the evaluation of annealing requirements

  6. Renal function study assessed by 99mTc-DMSA renal scintigraphy before and after PNL

    International Nuclear Information System (INIS)

    Sakurai, Masaki; Hioki, Takuichi; Okuno, Toshiyuki; Sugimura, Yoshiki; Yamakawa, Kensuke; Yanagawa, Makoto; Tajima, Kazuhiro; Tochigi, Hiromi; Kawamura, Juichi

    1990-01-01

    99m Tc-DMSA renal scintigraphy was carried out in 54 patients with unilateral renal stones before and after PNL. Four to 8 weeks after PNL the DMSA renal uptake significantly decreased to 17.2±6.0% from 18.2±6.7% before PNL. DMSA renal uptake did not change in the contralateral side. Since in some patients changes in the DMSA renal uptake of 5-7% were observed after PNL not only in the PNL side but also in the contralateral side, the renal function was assessed by the formula: DMSA renal uptake in the PNL side/DMSA renal uptake in the contralateral side, and the change of this ratio was evaluated in 44 patients, in whom the renal DMSA uptake in the PNL side was less than two times that in the contralateral side. The DMSA renal uptake ratio decreased to 95.6±8.7% from the base line 4-8 weeks after PNL. This change was statistically significant. Some functional risks such as massive bleeding with PNL, the fever after PNL and the number of nephrostomy tract did not affect the decrease in the renal function. In 29 patients in whom renal function was reevaluated one year after PNL, the DMSA renal uptake ratio significantly decreased to 94.2±9.6% from the base line 4-8 weeks after PNL. But the ratio significantly improved to 99.6±11.6% about one year after PNL. In two patients with a cold area on the renal image, the renal function of the operated side still remained at about 80% levels from the base line even one year after PNL. It is concluded that although renal function slightly decreased 4-8 weeks after PNL, it is expected to improve within one year after PNL. But in the case with a cold area on the renal image, the complete functional recovery would not be expected. 99m Tc-DMSA renal scintigraphy is a useful adjunct to evaluate the renal function before and after PNL. (author)

  7. Renal function assessed by 99mTc-DMSA scintigraphy before and after percutaneous nephrostolithotripsy (PNL)

    International Nuclear Information System (INIS)

    Sakurai, Masaki; Hioki, Takuichi; Kitano, Tokio; Nakagawa, Tsuyoshi; Yamaguchi, Nobuo; Kawamura, Juichi

    1988-01-01

    99m Tc-DMSA scintigraphy was carried out in 43 patients with unilateral renal stones before and after PNL. This study was repeated about one year after PNL in 12 patients. DMSA renal uptake was calculated two hours after injection of 99m Tc-DMSA. The study was performed using the dual type gamma camera. The renal function was assessed by the formula : 99m Tc-DMSA renal uptake of the operated side/ 99m Tc-DMSA renal uptake of the contralateral side. The change (ratio before/after PNL) x 100 was regarded as the percent change of renal function. Local abnormalities in the 99m Tc-DMSA renal scintigram after PNL were observed in 15 patients. The renal function decreased significantly to 95.8 ± 8.7 % from the base line 4 - 8 weeks after PNL. The renal function improved significantly to 98.6 ± 14.7 % from 92.1 ± 11.9 % in 12 patients about one year after PNL. It is concluded that although the renal function slightly decreased 4 - 8 weeks after PNL, it is expected to improve within 1 year after PNL. 99M Tc-DMSA scintigraphy is a useful adjunct to evaluate the renal function before and after PNL. (author)

  8. Integrity assessment plan for PNL 300 area radioactive hazardous waste tank system. Final report

    International Nuclear Information System (INIS)

    1996-03-01

    The Pacific Northwest Laboratory (PNL), operated by Battelle Memorial Institute under contract to the U.S. Department of Energy, operates tank systems for the U.S. Department of Energy, Richland Operations Office (DOE-RL), that contain dangerous waste constituents as defined by Washington State Department of Ecology (WDOE) Dangerous Waste Regulations, Washington Administrative Code (WAC) 173-303-040(18). Chapter 173-303-640(2) of the WAC requires the performance of integrity assessments for each existing tank system that treats or stores dangerous waste, except those operating under interim status with compliant secondary containment. This Integrity Assessment Plan (IAP) identifies all tasks that will be performed during the integrity assessment of the PNL-operated Radioactive Liquid Waste Systems (RLWS) associated with the 324 and 325 Buildings located in the 300 Area of the Hanford Site. It describes the inspections, tests, and analyses required to assess the integrity of the PNL RLWS (tanks, ancillary equipment, and secondary containment) and provides sufficient information for adequate budgeting and control of the assessment program. It also provides necessary information to permit the Independent, Qualified, Registered Professional Engineer (IQRPE) to approve the integrity assessment program

  9. Integrity assessment plan for PNL 300 area radioactive hazardous waste tank system. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    The Pacific Northwest Laboratory (PNL), operated by Battelle Memorial Institute under contract to the U.S. Department of Energy, operates tank systems for the U.S. Department of Energy, Richland Operations Office (DOE-RL), that contain dangerous waste constituents as defined by Washington State Department of Ecology (WDOE) Dangerous Waste Regulations, Washington Administrative Code (WAC) 173-303-040(18). Chapter 173-303-640(2) of the WAC requires the performance of integrity assessments for each existing tank system that treats or stores dangerous waste, except those operating under interim status with compliant secondary containment. This Integrity Assessment Plan (IAP) identifies all tasks that will be performed during the integrity assessment of the PNL-operated Radioactive Liquid Waste Systems (RLWS) associated with the 324 and 325 Buildings located in the 300 Area of the Hanford Site. It describes the inspections, tests, and analyses required to assess the integrity of the PNL RLWS (tanks, ancillary equipment, and secondary containment) and provides sufficient information for adequate budgeting and control of the assessment program. It also provides necessary information to permit the Independent, Qualified, Registered Professional Engineer (IQRPE) to approve the integrity assessment program.

  10. Prospective comparative study of miniperc and standard PNL for treatment of 1 to 2 cm size renal stone.

    Science.gov (United States)

    Mishra, Shashikant; Sharma, Rajan; Garg, Chandrapraksh; Kurien, Abraham; Sabnis, Ravindra; Desai, Mahesh

    2011-09-01

    • To evaluate the results of miniperc vis-à-vis standard PNL in the treatment of stones of 1-2 cm in size. Miniperc may represent a reasonable procedure in patients with nonbulky urolithiasis offering a similar outcome as standard percutaneous nephrolithotomy (PNL) with advantage of reduced morbidity. • 55 procedures including 27 miniperc and 28 standard PNL were performed for renal stones 1-2 cm in size. Pediatric patient, active urinary tract infection, renal malformation, uncorrected coagulopathy and morbid obesity patients were excluded from the study. • The parameters studied were demography, operative time, postoperative analgesic requirement, hemoglobin drop, complications and stone clearance. • Mean tract size was 18.2 ± 2 F (15-20) and 26.8 ± 2 F (24-30), P value PNL, respectively. Holmium LASER and pneumatic lithotripter were the main energy sources used in miniperc and standard PNL, respectively. • Miniperc operative time was longer than that of standard PNL (45.2 ± 12.6 vs 31 ± 16.6 min, P= 0.0008 respectively). • Conversely, there was an advantage of miniperc over standard PNL in terms of a significantly reduced hemoglobin drop (0.8 ± 0.9 vs 1.3 ± 0.4 gram%, P= 0.01), analgesic requirement (55.4 ± 50 vs 70.2 ± 52 mg tramadol, P= 0.29) and hospital stay (3.2 ± 0.8 vs 4.8 ± 0.6 days, P ≤ 0.001), respectively. • Intra- operative conversion of the procedure into a tubeless PNL was significantly more in the miniperc group (P ≤ 0.001). The miniperc and standard PNL group had clearance rates of 96% and 100%, respectively at 1 month follow up. • This study demonstrated significant advantages of the miniperc procedure in terms of reduced bleeding leading to a tubeless procedure and reduced hospital stay. • The stone free rates and the complications were similar in either group. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  11. Day care PNL using 'Santosh-PGI hemostatic seal' versus standard PNL: A randomized controlled study.

    Science.gov (United States)

    Kumar, Santosh; Singh, Shivanshu; Singh, Prashant; Singh, Shrawan Kumar

    2016-01-01

    To compare the outcomes of tubeless day care PNL using hemostatic seal in the access tract versus standard PNL. It was a prospective randomized controlled study. Cases were randomized to either the day care group with hemostatic seal (DCS) or the control group where patients were admitted and a nephrostomy tube was placed at the conclusion of surgery. A total of 180 cases were screened and out of these, 113 were included in the final analysis. The stone clearance rates were comparable in both the groups. The mean drop in hemoglobin was significantly lower in DCS group than the control group (1.05 ±0.68 vs. 1.30 ±0.58 gm/dl, p = 0.038).Mean postoperative pain score, analgesic requirement (paracetamol) and duration of hospital stay were also significantly lower in the DCS group (3.79 ±1.23 vs. 6.12 ±0.96, 1.48 ±0.50 vs. 4.09 ±1.11 grams and 0.48 ±0.26 vs. 4.74 ±1.53 days respectively; p PNL with composite hemostatic tract seal is considered safe. It resulted in a significant reduction of blood loss and analgesic requirement with significantly reduced hospital stay, nephrostomy tube site morbidity and time required to resume normal activity when compared to the standard PNL. However, patients must be compliant with the given instructions and should have access to a health care facility, as few of them may need re-admission.

  12. The patient position for PNL: does it matter?

    Science.gov (United States)

    Cracco, Cecilia Maria; Scoffone, Cesare Marco; Poggio, Massimiliano; Scarpa, Roberto Mario

    2010-03-01

    Currently, PNL is the treatment of choice for large and/or otherwise complex urolithiasis. PNL was initially performed with the patient in a supine-oblique position, but later on the prone position became the conventional one for habit and handiness. The prone position provides a larger area for percutaneous renal access, a wider space for instrument manipulation, and a claimed lower risk of splanchnic injury. Nonetheless, it implies important anaesthesiological risks, including circulatory, haemodynamic, and ventilatory difficulties; need of several nurses to be present for intraoperative changes of the decubitus in case of simultaneous retrograde instrumentation of the ureter, implying evident risks related to pressure points; an increased radiological hazard to the urologist's hands; patient discomfort. To overcome these drawbacks, various safe and effective changes in patient positioning for PNL have been proposed over the years, including the reverse lithotomy position, the prone split-leg position, the lateral decubitus, the supine position, and the Galdakao-modified supine Valdivia (GMSV) position. Among these, the GMSV position is safe and effective, and seems profitable and ergonomic. It allows optimal cardiopulmonary control during general anaesthesia; an easy puncture of the kidney; a reduced risk of colonic injury; simultaneous antero-retrograde approach to the renal cavities (PNL and retrograde ureteroscopy = ECIRS, Endoscopic Combined IntraRenal Surgery), with no need of intraoperative repositioning of the anaesthetized patient, less need for nurses in the operating room, less occupational risk due to shifting of heavy loads, less risk of pressure injuries related to inaccurate repositioning, and reduced duration of the procedure; facilitated spontaneous evacuation of stone fragments; a comfortable sitting position and a restrained X-ray exposure of the hands for the urologist. But, first of all, GMSV position fully supports a new comprehensive

  13. Two-dimensional benchmark calculations for PNL-30 through PNL-35

    International Nuclear Information System (INIS)

    Mosteller, R.D.

    1997-01-01

    Interest in critical experiments with lattices of mixed-oxide (MOX) fuel pins has been revived by the possibility that light water reactors will be used for disposition of weapons-grade plutonium. A series of six experiments with MOX lattices, designated PNL-30 through PNL-35, was performed at Pacific Northwest Laboratories in 1975 and 1976, and a set of benchmark specifications for these experiments subsequently was adopted by the Cross Section Evaluation Working Group (CSEWG). Although there appear to be some problems with these experiments, they remain the only CSEWG benchmarks for MOX lattices. The number of fuel pins in these experiments is relatively low, corresponding to fewer than 4 typical pressurized-water-reactor fuel assemblies. Accordingly, they are more appropriate as benchmarks for lattice-physics codes than for reactor-core simulator codes. Unfortunately, the CSEWG specifications retain the full three-dimensional (3D) detail of the experiments, while lattice-physics codes almost universally are limited to two dimensions (2D). This paper proposes an extension of the benchmark specifications to include a 2D model, and it justifies that extension by comparing results from the MCNP Monte Carlo code for the 2D and 3D specifications

  14. Two pectin lyase genes, pnl-1 and pnl-2, from Colletotrichum gloeosporioides f. sp. malvae differ in a cellulose-binding domain and in their expression during infection of Malva pusilla.

    Science.gov (United States)

    Wei, Yangdou; Shih, Jenny; Li, Jieran; Goodwin, Paul H

    2002-07-01

    Two pectin lyase genes, designated pnl-1 and pnl-2, were cloned from Colletotrichum gloeosporioides f. sp. malvae, a pathogen of round-leaved mallow (Malva pusilla). pnl-1 was isolated using cDNA from infected plant material; pnl-2 was isolated using cDNA from 3-day-old mycelia grown in mallow-cell-wall extract (MCWE) broth. pnl-1 is the first pectinase gene described thus far to encode a cellulose-binding domain (CBD), which is common in cellulases and xylanases, whereas pnl-2 encodes a pectin lyase that lacks a CBD. In pure culture, pnl-1 expression could be detected when purified pectin or glucose was the sole carbon source, but not when MCWE was the sole carbon source. The lack of pnl-1 expression appeared to be due to gene repression by some unknown factor(s) in the cell-wall extract. In contrast, expression of pnl-2 was detected in cultures when MCWE, but not when purified pectin or glucose, was the sole carbon source. In infected tissue, detection of pnl-1 expression by Northern-blot hybridization and by RT-PCR began with the onset of the necrotrophic phase of infection. Expression ofpnl-2 was not detectable by Northern-blot hybridization, but was observed byRT-PCR in both the biotrophic and necrotrophic phases of infection. The differences between pnl-1 and pnl-2 (i.e. pnl-1 encoding a CBD and differences in the expression patterns of both genes) may be related to the requirements of C. gloeosporioides f. sp. malvae to be able to grow in host tissue under the different conditions present during the biotrophic and necrotrophic phases of infection.

  15. Day care PNL using ‘Santosh-PGI hemostatic seal’ versus standard PNL: A randomized controlled study

    Science.gov (United States)

    Singh, Shivanshu; Singh, Prashant; Singh, Shrawan Kumar

    2016-01-01

    Introduction To compare the outcomes of tubeless day care PNL using hemostatic seal in the access tract versus standard PNL. Material and methods It was a prospective randomized controlled study. Cases were randomized to either the day care group with hemostatic seal (DCS) or the control group where patients were admitted and a nephrostomy tube was placed at the conclusion of surgery. Results A total of 180 cases were screened and out of these, 113 were included in the final analysis. The stone clearance rates were comparable in both the groups. The mean drop in hemoglobin was significantly lower in DCS group than the control group (1.05 ±0.68 vs. 1.30 ±0.58 gm/dl, p = 0.038).Mean postoperative pain score, analgesic requirement (paracetamol) and duration of hospital stay were also significantly lower in the DCS group (3.79 ±1.23 vs. 6.12 ±0.96, 1.48 ±0.50 vs. 4.09 ±1.11 grams and 0.48 ±0.26 vs. 4.74 ±1.53 days respectively; p PNL with composite hemostatic tract seal is considered safe. It resulted in a significant reduction of blood loss and analgesic requirement with significantly reduced hospital stay, nephrostomy tube site morbidity and time required to resume normal activity when compared to the standard PNL. However, patients must be compliant with the given instructions and should have access to a health care facility, as few of them may need re-admission. PMID:27551557

  16. The pectin lyase-encoding gene (pnl) family from Glomerella cingulata: characterization of pnlA and its expression in yeast.

    Science.gov (United States)

    Templeton, M D; Sharrock, K R; Bowen, J K; Crowhurst, R N; Rikkerink, E H

    1994-05-03

    Oligodeoxyribonucleotide primers were designed from conserved amino acid (aa) sequences between pectin lyase D (PNLD) from Aspergillus niger and pectate lyases A and E (PELA/E) from Erwinia chrysanthemi. The polymerase chain reaction (PCR) was used with these primers to amplify genomic DNA from the plant pathogenic fungus Glomerella cingulata. Three different 220-bp fragments with homology to PNL-encoding genes from A. niger, and a 320-bp fragment with homology to PEL-encoding genes from Nicotiana tabacum and E. carotovora were cloned. One of the 220-bp PCR products (designated pnlA) was used as a probe to isolate a PNL-encoding gene from a lambda genomic DNA library prepared from G. cingulata. Nucleotide (nt) sequence data revealed that this gene has seven exons and codes for a putative 380-aa protein. The nt sequence of a cDNA clone, prepared using PCR, confirmed the presence of the six introns. The positions of the introns were different from the sites of the five introns present in the three PNL-encoding genes previously sequenced from A. niger. PNLA was synthesised in yeast by cloning the cDNA into the expression vector, pEMBLYex-4, and enzymatically active protein was secreted into the culture medium. Significantly higher expression was achieved when the context of the start codon, CACCATG, was mutated to CAAAATG, a consensus sequence commonly found in highly expressed yeast genes. The produced protein had an isoelectric point (pI) of 9.4, the same as that for the G. cingulata pnlA product.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Investigation of roles for LRR-RLKs PNL1 and PNL2 in asymmetric cell division in Arabidopsis thaliana

    OpenAIRE

    Rodriguez, Maiti Celina

    2008-01-01

    Asymmetric cell division is a vital component of plant development. It enables cell differentiation and cell diversity. A key component of asymmetric cell division is cell signaling. Signals are believed to control polarization and orientation of asymmetric divisions during stomatal development. The findings of this report suggest that PNL1 and PNL2, two LRR-RLKs found in Arabidopsis and closely related to maize PAN1 LRR-RLK, are possibly involved in the signaling events occurring during the ...

  18. Ultrasonography-guided PNL in comparison with laparoscopic ureterolithotomy in the management of large proximal ureteral stone.

    Science.gov (United States)

    Karami, Hossein; Mazloomfard, Mohammad Mohsen; Lotfi, Behzad; Alizadeh, Asghar; Javanmard, Babak

    2013-01-01

    The aim of study was to evaluate the clinical outcomes of PNL in comparison with laparoscopic ureterolithotomy (LUL) in proximal ureteral stones larger than 1 cm. A total of 80 patients who were candidates for treatment of large ureteral stones in our urology center were enrolled in the study between September 2004 and September 2008. By using patient randomization, they were assigned into two forty-patient groups (PNL and LUL). After evaluating the patients with laboratory tests and IVP, PNL was performed under sonography guidance in the prone position or the patients were submitted to classic laparoscopic ureterolithotomy (LUL) transperitoneally. All patients underwent postoperative assessments including KUB and ultrasonography. A hundred-percent success was achieved in both groups. The mean age of the patients were 39.4 (16-63) and 35.2 (18-57) years old in PNL and LUL groups, respectively. The mean stone size in PNL group was 14.2 (10-25) mm and in LUL group was 13.5 (10-28) mm. The duration of the operations were 54.35 (50-82) minutes, and 82.15 (73-180) minutes (P PNL and LUL, accordingly. The mean Hb decrease in PNL group was 0.9mg/dL and in LUL group was 0.4mg/dL (p = 0.001). No statistically significant differences in terms of blood transfusion, fever, ICU admission, and prolonged urinary leakage were detected in both groups. According to our study, percutaneous nephrolithotomy under ultrasonography guidance is comparable with the laparoscopic ureterolithotomy for the treatment of proximal ureteral stones larger than 1 cm.

  19. Single Shell Tank Waste Characterization Project for Tank B-110, Core 9 - data package and PNL validation summary report

    International Nuclear Information System (INIS)

    Pool, K.N.; Jones, T.E.; McKinley, S.G.; Tingey, J.M.; Longaker, T.M.; Gibson, J.A.

    1990-01-01

    This Data Package contains results obtained by Pacific Northwest Laboratory (PNL) staff in the characterization and analyses of Core 9 segments taken from the Single-Shell Tank (SST) 110B. The characterization and analysis of Core 9 segments are outlined in the Waste Characterization Plan for Hanford Site Single-Shell Tanks and in the Pacific Northwest Laboratory (PNL) Single-Shell Tank Waste Characterization Support FY 89/90 Statement of Work (SOW), Rev. 1 dated March, 1990. Specific analyses for each sub-sample taken from a segment are delineated in Test Instructions prepared by the PNL Single-Shell Tank Waste Characterization Project Management Office (SST Project) in accordance with procedures contained in the SST Waste Characterization Procedure Compendium (PNL-MA-599). Analytical procedures used in the characterization activities are also included in PNL-MA-599. Core 9 included five segments although segment 1 did not have sufficient material for characterization. The five samplers were received from Westinghouse Hanford Company (WHC) on 11/21-22/89. Each segment was contained in a sampler and was enclosed in a shipping cask. The shipping cask was butted up to the 325-A hot cell and the sampler moved into the hot cell. The material in the sampler (i.e., the segment) was extruded from the sampler, limited physical characteristics assessed, and photographed. At this point samples were taken for particle size and volatile organic analyses. Each segment was then homogenized. Sub-samples were taken for required analyses as delineated in the appropriate Test Instruction. Table 1 includes sample numbers assigned to Core 9 segment materials being transferred from 325-A Hot Cell. Sample numbers 90-0298, 90-0299, 90-0302, and 90-0303 were included in Table 1 although no analyses were requested for these samples. Table 2 lists Core 9 sub-sample numbers per sample preparation method

  20. Environmental monitoring master sampling schedule: January--December 1989

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1989-01-01

    Environmental monitoring of the Hanford Site is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for calendar year 1989 for the Surface and Ground-Water Environmental Monitoring Projects. This schedule is subject to modification during the year in response to changes in Site operations, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. This schedule includes routine ground-water sampling performed by PNL for Westinghouse Hanford Company, but does not include samples that may be collected in 1989 to support special studies or special contractor projects, or for quality control. The sampling schedule for Site-wide chemical monitoring is not included here, because it varies each quarter as needed, based on past results and operating needs. This schedule does not include Resource Conservation and Recovery Act ground-water sampling performed by PNL for Hanford Site contractors, nor does it include sampling that may be done by other DOE Hanford contractors

  1. FY 1995 research highlights: PNL accomplishments in OER programs

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-01

    Pacific Northwest Laboratory (PNL) conducts fundamental and applied research in support of the US Department of Energy`s (DOE) core missions in science and technology, environmental quality, energy resources, and national security. Much of this research is funded by the program offices of DOE`s Office of Energy Research (DOE-ER), primarily the Office of Basic Energy Sciences (BES) and the Office of Health and Environmental Research (OHER), and by PNL`s Laboratory Directed Research and Development (LDRD) Program. This document is a collection of research highlights that describe PNL`s accomplishments in DOE-ER funded programs during Fiscal Year 1995. Included are accomplishments in research funded by OHER`s Analytical Technologies, Environmental Research, Health Effects, General Life Sciences, and Carbon Dioxide Research programs; BES`s Materials Science, Chemical Sciences, Engineering and Geoscience, and Applied Mathematical Sciences programs; and PNL`s LDRD Program. Summaries are given for 70 projects.

  2. Ultrasonography-guided PNL in comparison with laparoscopic ureterolithotomy in the management of large proximal ureteral stone

    Directory of Open Access Journals (Sweden)

    Hossein Karami

    2013-01-01

    Full Text Available Purpose: The aim of study was to evaluate the clinical outcomes of PNL in comparison with laparoscopic ureterolithotomy (LUL in proximal ureteral stones larger than 1 cm. Materials and Methods: A total of 80 patients who were candidates for treatment of large ureteral stones in our urology center were enrolled in the study between September 2004 and September 2008. By using patient randomization, they were assigned into two forty-patient groups (PNL and LUL. After evaluating the patients with laboratory tests and IVP, PNL was performed under sonography guidance in the prone position or the patients were submitted to classic laparoscopic ureterolithotomy (LUL transperitoneally. All patients underwent postoperative assessments including KUB and ultrasonography. Results: A hundred-percent success was achieved in both groups. The mean age of the patients were 39.4 (16-63 and 35.2 (18-57 years old in PNL and LUL groups, respectively. The mean stone size in PNL group was 14.2 (10-25 mm and in LUL group was 13.5 (10-28 mm. The duration of the operations were 54.35 (50-82 minutes, and 82.15 (73-180 minutes (P < 0.0001; and the average hospital stay days were 2.6 (2-5 and 3.5 (3-8 days (p = 0.011 in groups PNL and LUL, accordingly. The mean Hb decrease in PNL group was 0.9mg/dL and in LUL group was 0.4mg/dL (p = 0.001. No statistically significant differences in terms of blood transfusion, fever, ICU admission, and prolonged urinary leakage were detected in both groups. Conclusion: According to our study, percutaneous nephrolithotomy under ultrasonography guidance is comparable with the laparoscopic ureterolithotomy for the treatment of proximal ureteral stones larger than 1 cm.

  3. PNL size reduction and decontamination facilities and capabilities

    International Nuclear Information System (INIS)

    Allen, R.P.; Fetrow, L.K.; McCoy, M.W.

    1983-07-01

    Studies sponsored by the US Department of Energy at Pacific Northwest Laboratory (PNL) have resulted in the development of an effective, integrated size reduction and decontamination system for transuranically contaminated components. Using this system, a reduction of more than 95% in the volume of transuranic waste requiring interim storage and eventual geologic disposal has been achieved for typical plutonium contaminated glove boxes. This paper describes the separate preparation, size reduction, decontamination and waste treatment operations and facilities that have been developed and demonstrated as part of this work

  4. The effects of previous open renal stone surgery types on PNL outcomes.

    Science.gov (United States)

    Ozgor, Faruk; Kucuktopcu, Onur; Ucpinar, Burak; Sarilar, Omer; Erbin, Akif; Yanaral, Fatih; Sahan, Murat; Binbay, Murat

    2016-01-01

    Our aim was to demonstrate the effect of insicion of renal parenchyma during open renal stone surgery (ORSS) on percutaneous nephrolithotomy (PNL) outcomes. Patients with history of ORSS who underwent PNL operation between June 2005 and June 2015 were analyzed retrospectively. Patients were divided into two groups according to their type of previous ORSS. Patients who had a history of ORSS with parenchymal insicion, such as radial nephrotomies, anatrophic nephrolithotomy, lower pole resection, and partial nephrectomy, were included in Group 1. Other patients with a history of open pyelolithotomy were enrolled in Group 2. Preoperative characteristics, perioperative data, stone-free status, and complications were compared between the groups. Stone-free status was defined as complete clearance of stone(s) or presence of residual fragments smaller than 4 mm. The retrospective nature of our study, different experience level of surgeons, and lack of the evaluation of anesthetic agents and cost of procedures were limitations of our study. 123 and 111 patients were enrolled in Groups 1 and 2, respectively. Preoperative characteristics were similar between groups. In Group 1, the mean operative time was statistically longer than in Group 2 (p=0.013). Stone-free status was significantly higher in Group 2 than in Group 1 (p=0.027). Complication rates were similar between groups. Hemorrhage requiring blood transfusion was the most common complication in both groups (10.5% vs. 9.9%). Our study demonstrated that a history of previous ORSS with parenchymal insicion significantly reduces the success rates of PNL procedure.

  5. Cleanup Verification Package for the 118-F-5 PNL Sawdust Pit

    International Nuclear Information System (INIS)

    Habel, L.D.

    2008-01-01

    This cleanup verification package documents completion of remedial action, sampling activities, and compliance with cleanup criteria for the 118-F-5 Burial Ground, the PNL (Pacific Northwest Laboratory) Sawdust Pit. The 118-F-5 Burial Ground was an unlined trench that received radioactive sawdust from the floors of animal pens in the 100-F Experimental Animal Farm

  6. Does the nephrostomy tract length impact the outcomes of percutaneous nephrolithotomy (PNL)?

    Science.gov (United States)

    Astroza, Gaston M; Neisius, Andreas; Tsivian, Matvey; Wang, Agnes J; Preminger, Glenn M; Lipkin, Michael E

    2014-12-01

    Different factors can determine the outcomes of percutaneous nephrolithotomy (PNL). We analyzed the effect of tract length (TL) on outcomes after PNL. We performed a retrospective review of patients undergoing PNL between 2006 and 2011. Patients with preoperative computed tomography (CT), one percutaneous access tract and follow-up imaging within 3 months were included. TL was defined as distance between the skin to the calyx of puncture as measured on preoperative CT. Measurements were independently performed by two urologists and the average was used for analysis. Stone-free rate (SFR) was defined as zero fragments on follow-up imaging. Factors independently associated with the likelihood of being stone-free after PNL were determined using multivariable analysis adjusted for TL, location of access, the presence of incomplete or complete staghorn calculi and type of follow-up imaging. Complications (Clavien score) were independently assessed. A total of 222 patients were included. Median stone burden and body mass index (BMI) was 239.4 mm(2) and 30.5 [interquartile range (IQR): 25.7-36.2]. The median TL was 85.0 mm (IQR: 70.3-100.0) and highly correlated with BMI (ρ = 0.66, p PNL. PNL is a safe and effective treatment for stones in patients with differing body habitus.

  7. Quality assurance programs at the PNL calibrations laboratory

    International Nuclear Information System (INIS)

    Piper, R.K.; McDonald, J.C.; Fox, R.A.; Eichner, F.N.

    1993-03-01

    The calibrations laboratory at Pacific Northwest Laboratory (PNL) serves as a radiological standardization facility for personnel and environmental dosimetry and radiological survey instruments. As part of this function, the calibrations laboratory must maintain radiological reference fields with calibrations traceable to the National Institute of Standards and Technology (NIST). This task is accomplished by a combination of (1) sources or reference instruments calibrated at or by NIST, (2) measurement quality assurance (MQA) interactions with NIST, and (3) rigorous internal annual and quarterly calibration verifications. This paper describes a representative sample of the facilities, sources, and actions used to maintain accurate and traceable fields

  8. Environmental monitoring master sampling schedule, January--December 1990

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1990-01-01

    Environmental monitoring of the Hanford Site is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for calendar year 1990 for the Environment Surveillance and Ground-Water Monitoring Projects. This schedule is subject to modification during the year in response to changes in Site operations, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs. This schedule includes ground-water sampling performed by PNL for environmental surveillance of the Hanford Site.

  9. Review of continuous ceramic-lined melter and associated experience at PNL

    International Nuclear Information System (INIS)

    Buelt, J.L.; Chapman, C.C.; Barnes, S.M.; Dierks, R.D.

    1979-01-01

    Development of continuous, ceramic-lined melters applicable to immobilization of radioactive wastes began at PNL in 1973. A comprehensive program is curretly in progress. The melters constructed at PNL have incorporated remote and reliable design features necessary for radioactive use. The extensive experience with vitrification of simulated wastes has proven the continuous melter's applicability to radioactive waste immobilization

  10. Supine or prone position for mini-PNL procedure: does it matter.

    Science.gov (United States)

    Tokatlı, Zafer; Gokce, Mehmet Ilker; Süer, Evren; Sağlam, Remzi

    2015-06-01

    In this study it is aimed to compare the success and complication rates of mini-PNL procedure in supine and prone positions. In this retrospective study data of 180 patients treated with MPNL either in supine (n = 54) or prone (n = 126) positions between May 2009 and August 2014 was investigated. Success was defined as no visible stones >2 mm. Perioperative complications were classified using the modified Clavien system. Groups were compared with Chi square test or Student t test and for statistical significance p value of 0.05 was accepted. Mean age of the population was 42.5 ± 8.2 years and mean stone size was 23.9 ± 4.1 mm. The two groups were similar with regard to demographic characteristics and stone related characteristics except the ASA status. Success rates of the supine and prone groups were 85.1 and 87.3%, respectively (p = 0.701). No statistically significant differences in terms of complications were observed. Mean operative time was the only parameter different between the two groups (55 vs 82 min, p = 0.001). Supine position for PNL seems to be promising and the complication and success rates are shown to be similar to the prone position with MPNL technique. The only significant benefit of this technique is shorter operative time.

  11. Remaining Sites Verification Package for the 116-F-16, PNL Outfall and the 100-F-43, PNL Outfall Spillway. Attachment to Waste Site Reclassification Form 2006-039 and 2006-096

    International Nuclear Information System (INIS)

    Dittmer, L.M.

    2006-01-01

    The 116-F-16 waste site is the former Pacific National Laboratories (PNL) Outfall, used to discharge waste effluents from the 100-F Experimental Animal Farm. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River

  12. APORTACIONES DE LA PNL A LA EDUCACIÓN EMOCIONAL

    Directory of Open Access Journals (Sweden)

    Mayca Pérez Asensio

    2012-05-01

    Full Text Available La PNL (Programación neurolingüística es un conjunto de técnicas y habilidades que mejoran nuestras comunicaciones interpersonales, nos amplían la propia  perspectiva, lo que nos ayuda al crecimiento personal,  con hondas repercusiones en el aprendizaje. Sobre la base científica de lo que conocemos del cerebro, nos ayuda a descubrir nuestro mapa de la realidad, de nuestras representaciones –imágenes, sonidos, sensaciones, recuerdos, estímulos, etc.- sobre los que se ancla el PNL en el aula, permitiendo la expresión de las emociones y de la acción a ellas vinculada.

  13. Flexible ureterorenoscopy versus miniaturized PNL for solitary renal calculi of 10-30 mm size.

    Science.gov (United States)

    Knoll, Thomas; Jessen, Jan Peter; Honeck, Patrick; Wendt-Nordahl, Gunnar

    2011-12-01

    The value of flexible ureterorenoscopy (fURS) and miniaturized PNL (mPNL) for larger renal calculi is under discussion. This non-randomized prospective study aimed to evaluate fURS and mPNL for solitary renal stones of 10-30 mm size. fURS was carried out in 21 patients with last generation 7.5F endoscopes. Ureteral access sheaths were used in 19 patients. For mPNL, an 18F modified Amplatz sheath with a 14F nephroscope were used (n = 25). The procedure was performed either tubeless with an antegrade stent or a nephrostomy. Outcome and complications of both procedures were assessed. Patients' demographics and stone sizes were comparable (18 ± 5 vs. 19 ± 4 mm, P = 0.08). Patients in the fURS group had a higher mean BMI (31 vs. 27, P < 0.05). Total OR time was significantly longer for fURS (106 ± 51 vs. 59 ± 19 min., P < 0.001). More patients were stone-free after one single percutaneous treatment, while 2nd-stage treatments with fURS were common (total procedures 1.04 vs. 1.52, P < 0.001; immediate stone-free rate (SFR) 96% vs. 71.5%, P < 0.001). SFR after 4 weeks was 100% (mPNL) and 85.8% (fURS) (P < 0.01). Minor complications as classified by Clavien I or II occurred in 16 and 23.8%, mPNL and fURS, respectively, P = 0.13). No major complications (Clavien III-V) occured in both groups. Our series supports both the concept of either percutaneous or retrograde endoscopic treatment for renal calculi with both modalities offering excellent safety. However, while for fURS, a significantly higher rate of 2nd-stage procedures was necessary, and mPNL led to faster and higher SFR without increasing complication rate.

  14. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1995-02-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy (DOE). This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring onsite drinking water falls outside the scope of the SESP. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control, and reporting. The ground-water sampling schedule identifies ground-water sampling .events used by PNL for environmental surveillance of the Hanford Site. Sampling is indicated as annual, semi-annual, quarterly, or monthly in the sampling schedule. Some samples are collected and analyzed as part of ground-water monitoring and characterization programs at Hanford (e.g. Resources Conservation and Recovery Act (RCRA), Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), or Operational). The number of samples planned by other programs are identified in the sampling schedule by a number in the analysis column and a project designation in the Cosample column. Well sampling events may be merged to avoid redundancy in cases where sampling is planned by both-environmental surveillance and another program

  15. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1995-02-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy (DOE). This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring onsite drinking water falls outside the scope of the SESP. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control, and reporting. The ground-water sampling schedule identifies ground-water sampling .events used by PNL for environmental surveillance of the Hanford Site. Sampling is indicated as annual, semi-annual, quarterly, or monthly in the sampling schedule. Some samples are collected and analyzed as part of ground-water monitoring and characterization programs at Hanford (e.g. Resources Conservation and Recovery Act (RCRA), Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), or Operational). The number of samples planned by other programs are identified in the sampling schedule by a number in the analysis column and a project designation in the Cosample column. Well sampling events may be merged to avoid redundancy in cases where sampling is planned by both-environmental surveillance and another program.

  16. Gene inactivation in the plant pathogen Glomerella cingulata: three strategies for the disruption of the pectin lyase gene pnlA.

    Science.gov (United States)

    Bowen, J K; Templeton, M D; Sharrock, K R; Crowhurst, R N; Rikkerink, E H

    1995-01-20

    The feasibility of performing routine transformation-mediated mutagenesis in Glomerella cingulata was analysed by adopting three one-step gene disruption strategies targeted at the pectin lyase gene pnlA. The efficiencies of disruption following transformation with gene replacement- or gene truncation-disruption vectors were compared. To effect replacement-disruption, G. cingulata was transformed with a vector carrying DNA from the pnlA locus in which the majority of the coding sequence had been replaced by the gene for hygromycin B resistance. Two of the five transformants investigated contained an inactivated pnlA gene (pnlA-); both also contained ectopically integrated vector sequences. The efficacy of gene disruption by transformation with two gene truncation-disruption vectors was also assessed. Both vectors carried at 5' and 3' truncated copy of the pnlA coding sequence, adjacent to the gene for hygromycin B resistance. The promoter sequences controlling the selectable marker differed in the two vectors. In one vector the homologous G. cingulata gpdA promoter controlled hygromycin B phosphotransferase expression (homologous truncation vector), whereas in the second vector promoter elements were from the Aspergillus nidulans gpdA gene (heterologous truncation vector). Following transformation with the homologous truncation vector, nine transformants were analysed by Southern hybridisation; no transformants contained a disrupted pnlA gene. Of nineteen heterologous truncation vector transformants, three contained a disrupted pnlA gene; Southern analysis revealed single integrations of vector sequence at pnlA in two of these transformants. pnlA mRNA was not detected by Northern hybridisation in pnlA- transformants. pnlA- transformants failed to produce a PNLA protein with a pI identical to one normally detected in wild-type isolates by silver and activity staining of isoelectric focussing gels. Pathogenesis on Capsicum and apple was unaffected by disruption of

  17. Renal access in PNL under sonographic guidance: Do we really need to insert an open end ureteral catheter in dilated renal systems? A prospective randomized study.

    Science.gov (United States)

    Eryildirim, Bilal; Tuncer, Murat; Camur, Emre; Ustun, Fatih; Tarhan, Fatih; Sarica, Kemal

    2017-10-03

    To evaluate the true necessity of open end ureteral catheter insertion in patients with moderate to severe pelvicalyceal system dilation treated with percutaneous nephrolithotomy (PNL) under sonographic guidance. 50 cases treated with PNL under sonographic guidance in prone position for solitary obstructing renal stones were evaluated. Patients were randomly divided into two groups; Group 1: Patients in whom a open end ureteral catheter was inserted prior to the procedure; Group 2: Patients receiving no catheter before PNL. In addition to the duration of the procedure as a whole and also all relevant stages as well, radiation exposure time, hospitalization period, mean nephrostomy tube duration, mean drop in Hb levels and all intra and postoperative complications have been evaluated. Mean size of the stones was 308.5 ± 133.2 mm2. Mean total duration of the PNL procedure in cases with open end ureteral catheter was significantly longer than the other cases (p < 0.001). Evaluation of the outcomes of the PNL procedures revealed no statistically significant difference between two groups regarding the stone-free rates (86% vs 84%). Additionally, there was no significant difference with respect to the duration of nephrostomy tube, hospitalization period and secondary procedures needed, complication rates as well as the post-operative Hb drop levels in both groups (p = 0.6830). Our results indicate that the placement of an open end ureteral catheter prior to a PNL procedure performed under sonographic access may not be indicated in selected cases presenting with solitary obstructing renal pelvic and/or calyceal stones.

  18. Remaining Sites Verification Package for the 116-F-16, PNL Outfall and the 100-F-43, PNL Outfall Spillway. Attachment to Waste Site Reclassification Form 2006-039 and 2006-046

    International Nuclear Information System (INIS)

    Dittmer, L.M.

    2006-01-01

    The 100-F-43 waste site is the portion of the former discharge spillway for the PNL Outfall formerly existing above the ordinary high water mark of the Columbia River. The spillway consisted of a concrete flume used to discharge waste effluents from the 100-F Experimental Animal Farm. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River

  19. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1994-02-01

    This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring the onsite drinking water falls outside the scope of the SESP. The Hanford Environmental Health Foundation is responsible for monitoring the nonradiological parameters as defined in the National Drinking Water Standards while PNL conducts the radiological monitoring of the onsite drinking water. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize the expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control and reporting. The ground-water sampling schedule identifies ground-water sampling events used by PNL for environmental surveillance of the Hanford Site

  20. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1994-02-01

    This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring the onsite drinking water falls outside the scope of the SESP. The Hanford Environmental Health Foundation is responsible for monitoring the nonradiological parameters as defined in the National Drinking Water Standards while PNL conducts the radiological monitoring of the onsite drinking water. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize the expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control and reporting. The ground-water sampling schedule identifies ground-water sampling events used by PNL for environmental surveillance of the Hanford Site.

  1. Histopathological examination of nerve samples from pure neural leprosy patients: obtaining maximum information to improve diagnostic efficiency.

    Science.gov (United States)

    Antunes, Sérgio Luiz Gomes; Chimelli, Leila; Jardim, Márcia Rodrigues; Vital, Robson Teixeira; Nery, José Augusto da Costa; Corte-Real, Suzana; Hacker, Mariana Andréa Vilas Boas; Sarno, Euzenir Nunes

    2012-03-01

    Nerve biopsy examination is an important auxiliary procedure for diagnosing pure neural leprosy (PNL). When acid-fast bacilli (AFB) are not detected in the nerve sample, the value of other nonspecific histological alterations should be considered along with pertinent clinical, electroneuromyographical and laboratory data (the detection of Mycobacterium leprae DNA with polymerase chain reaction and the detection of serum anti-phenolic glycolipid 1 antibodies) to support a possible or probable PNL diagnosis. Three hundred forty nerve samples [144 from PNL patients and 196 from patients with non-leprosy peripheral neuropathies (NLN)] were examined. Both AFB-negative and AFB-positive PNL samples had more frequent histopathological alterations (epithelioid granulomas, mononuclear infiltrates, fibrosis, perineurial and subperineurial oedema and decreased numbers of myelinated fibres) than the NLN group. Multivariate analysis revealed that independently, mononuclear infiltrate and perineurial fibrosis were more common in the PNL group and were able to correctly classify AFB-negative PNL samples. These results indicate that even in the absence of AFB, these histopathological nerve alterations may justify a PNL diagnosis when observed in conjunction with pertinent clinical, epidemiological and laboratory data.

  2. Summary of the PNL aircraft flights during the MAP3S-SURE cooperative program for summer 1978

    International Nuclear Information System (INIS)

    Alkezweeny, A.J.; Arbuthnot, D.R.; Busness, K.M.; Easter, R.C.; Lee, R.N.

    1979-01-01

    A summary of the Pacific Northwest Laboratory (PNL) aircraft flights, which were part of the Sulfur Regional (SURE) Intensive Experiment, conducted during the summer of 1978, is presented, and some preliminary measurement results are reported. The PNL DC-3 and Cessna 411 research aircraft were used on two consecutive days during the experiment to measure regional-scale pollutant problems over the Ohio Valley

  3. Histopathological examination of nerve samples from pure neural leprosy patients: obtaining maximum information to improve diagnostic efficiency

    Directory of Open Access Journals (Sweden)

    Sérgio Luiz Gomes Antunes

    2012-03-01

    Full Text Available Nerve biopsy examination is an important auxiliary procedure for diagnosing pure neural leprosy (PNL. When acid-fast bacilli (AFB are not detected in the nerve sample, the value of other nonspecific histological alterations should be considered along with pertinent clinical, electroneuromyographical and laboratory data (the detection of Mycobacterium leprae DNA with polymerase chain reaction and the detection of serum anti-phenolic glycolipid 1 antibodies to support a possible or probable PNL diagnosis. Three hundred forty nerve samples [144 from PNL patients and 196 from patients with non-leprosy peripheral neuropathies (NLN] were examined. Both AFB-negative and AFB-positive PNL samples had more frequent histopathological alterations (epithelioid granulomas, mononuclear infiltrates, fibrosis, perineurial and subperineurial oedema and decreased numbers of myelinated fibres than the NLN group. Multivariate analysis revealed that independently, mononuclear infiltrate and perineurial fibrosis were more common in the PNL group and were able to correctly classify AFB-negative PNL samples. These results indicate that even in the absence of AFB, these histopathological nerve alterations may justify a PNL diagnosis when observed in conjunction with pertinent clinical, epidemiological and laboratory data.

  4. Data report for the NRC/PNL Halden assembly IFA-431

    International Nuclear Information System (INIS)

    Hann, C.R.; Bradley, E.R.; Cunningham, M.E.; Lanning, D.D.; Marshall, R.K.; Williford, R.E.

    1978-04-01

    The report presents the in-reactor data collected from the NRC/PNL Halden Assembly IFA-431 as a part of the program entitled ''Experimental Verification of Steady State Fuel Codes,'' sponsored by the Fuel Behavior Research Branch of the USNRC. The purpose of this program is to reduce the uncertainties of calculating the thermal stored energy in an operating nuclear fuel rod. The report presents fuel centerline thermocouple readings, cladding elongation monitor readings, rod internal pressure readings, and neutron detector readings. The neutron detector readings were corrected to represent rod local powers at the thermocouple locations. These data are presented in the form of plots of the variables versus time during the irradiation period from June 1975 to February 1976. Also included are descriptions of the test rationale, assembly and rod designs, test facility, instrument array and calibration, and data processing methods. Topical reports discussing specific aspects and results of the data analysis are referenced

  5. Material balance area custodian performance evaluation program at PNL

    International Nuclear Information System (INIS)

    Dickman, D.A.

    1991-01-01

    This paper reports that the material balance area (MBA) custodian has primary responsibility for control and accountability of nuclear material within an MBA. In this role, the custodian operates as an extension of the facility material control and accountability (MC and A) organization. To effectively meet administrative requirements and protection needs, the custodian must be fully trained in all aspects of MC and A related to the MBA, and custodian performance must be periodically evaluated. U.S. Department of Energy (DOE) Policy requires that each facility provide for a program which ensures that personnel performing MC and A functions are trained and/or qualified to perform their duties and responsibilities and knowledgeable of requirements and procedures related to their functions. the MBA Custodian Performance Evaluation Program at Pacific Northwest Laboratory (PNL) uses a variety of assessment techniques to meet this goal, including internal and independent MBA audits, periodic custodian testing, limited scope performance tests, daily monitoring of MC and A documentation, and reviewing custodian performance during physical inventories

  6. Tank Vapor Characterization Project. Headspace vapor characterization of Hanford Waste Tank AX-102: Results from samples collected on June 27, 1995

    International Nuclear Information System (INIS)

    Clauss, T.W.; Pool, K.H.; Evans, J.C.; McVeety, B.D.; Thomas, B.L.; Olsen, K.B.; Fruchter, J.S.; Ligotke, M.W.

    1995-11-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-AX-102 (Tank AX-102) at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank-farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest Laboratory (PNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNL. Analyte concentrations were based on analytical results and, where appropriate, sample volumes provided by WHC. Detailed descriptions of the analytical results appear in the text

  7. Single-pass continuous-flow leach test of PNL 76-68 glass: some selected Bead Leach I results

    International Nuclear Information System (INIS)

    Coles, D.G.

    1981-01-01

    A single-pass continuous-flow leach test of PNL 76-68 glass beads (7 mm dia) was concluded after 420 days of uninterrupted operation. Variables included in the experimental matrix were flow-rate, leachant composition, and temperature. Analysis was conducted on all leachate samples for 237 Np and 239 Pu as well as a number of nonradioactive elements. Results indicated that flow-rate and leachant systematically affected the leach rate, but only slightly. Temperature effects were significant. Plutonium leach rate was lower at higher temperature suggesting that Pu sorption onto the beads was enhanced at the higher temperature. The range of leach rates for all analyzed elements (except Pu), at both temperatures, at all three flow rates, and with all three leachant compositions varied over only three orders of magnitude. The range of variables used in this experiment covered those expected in many proposed repository environments. The preliminary interpretation of the results aPPh 3 also reacted with Mn 2 (CO) 10 and Cp 2 Mo 2 (CO) 6 to give a variety of products at room temperature. A radical mechanism was suggested

  8. Tank Vapor Characterization Project: Vapor space characterization of waste Tank A-101, Results from samples collected on June 8, 1995

    International Nuclear Information System (INIS)

    Pool, K.H.; Clauss, T.W.; McVeety, B.D.; Evans, J.C.; Thomas, B.L.; Olsen, K.B.; Fruchter, J.S.; Ligotke, M.W.

    1995-11-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-A-101 (Tank A-101) at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank-farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest National Laboratory (PNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNL. Analyte concentrations were based on analytical results and, where appropriate, sample volumes provided by WHC. A summary of the results is listed in Table 1. Detailed descriptions of the analytical results appear in the text

  9. Vapor space characterization of waste tank 241-C-101: Results from samples collected on 9/1/94

    International Nuclear Information System (INIS)

    Lucke, R.B.; Clauss, T.W.; Ligotke, M.W.

    1995-11-01

    This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-C-101 (referred to as Tank C-101) and the ambient air collected - 30 ft upwind near the tank and through the VSS near the tank. Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The sample job was designated S4056, and samples were collected by WHC on September 1, 1994, using the vapor sampling system (VSS). The samples were inspected upon delivery to the 326/23B laboratory and logged into PNL record book 55408 before implementation of PNL Technical Procedure PNL-TVP-07. Custody of the sorbent traps was transferred to PNL personnel performing the inorganic analysis and stored at refrigerated (≤ 10 degrees C) temperature until the time of analysis. The canisters were stored in the 326/23B laboratory at ambient (25 degrees C) temperature until the time of the analysis. Access to the 326/23B laboratory is limited to PNL personnel working on the waste-tank safety program. Analyses described in this report were performed at PNL in the 300 area of the Hanford Reservation. Analytical methods that were used are described in the text. In summary, sorbent traps for inorganic analyses containing sample materials were either weighed (for water analysis) or desorbed with the appropriate aqueous solutions (for NH 3 , NO 2 , and NO analyses). The aqueous extracts were analyzed either by selective electrode or by ion chromatography (IC). Organic analyses were performed using cryogenic preconcentration followed by gas chromatography/mass spectrometry (GC/MS)

  10. Tank Vapor Characterization Project: Headspace vapor characterization of Hanford Waste Tank U-203, Results from samples collected on August 8, 1995

    International Nuclear Information System (INIS)

    Pool, K.H.; Clauss, T.W.; Evans, J.C.; McVeety, B.D.; Thomas, B.L.; Olsen, K.B.; Fruchter, J.S.; Ligotke, M.W.

    1995-11-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-U-203 (Tank U-203) at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank-farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest Laboratory (PNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNL. Analyte concentrations were based on analytical results and, where appropriate, sample volumes provided by WHC. A summary of the results is listed. Detailed descriptions of the analytical results appear in the text

  11. Tank Vapor Characterization Project: Headspace vapor characterization of Hanford Waste Tank U-204, Results from samples collected on August 8, 1995

    International Nuclear Information System (INIS)

    Clauss, T.W.; Evans, J.C.; McVeety, B.D.; Pool, K.H.; Thomas, B.L.; Olsen, K.B.; Fruchter, J.S.; Ligotke, M.W.

    1995-11-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-U-204 (Tank U-204) at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank-farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest National Laboratory (PNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNL. Analyte concentrations were based on analytical results and, where appropriate, sample volumes provided by WHC. A summary of the results is listed. Detailed descriptions of the analytical results appear in the text

  12. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1991-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Ground-Water Monitoring Project. The routine sampling plan for the SESP has been revised this year to reflect changing site operations and priorities. Some sampling previously performed at least annually has been reduced in frequency, and some new sampling to be performed at a less than annual frequency has been added. Therefore, the SESP schedule reflects sampling to be conducted in calendar year 1991 as well as future years. The ground-water sampling schedule is for 1991. This schedule is subject to modification during the year in response to changes in Site operation, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford evirons

  13. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1991-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Ground-Water Monitoring Project. The routine sampling plan for the SESP has been revised this year to reflect changing site operations and priorities. Some sampling previously performed at least annually has been reduced in frequency, and some new sampling to be performed at a less than annual frequency has been added. Therefore, the SESP schedule reflects sampling to be conducted in calendar year 1991 as well as future years. The ground-water sampling schedule is for 1991. This schedule is subject to modification during the year in response to changes in Site operation, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford evirons.

  14. The importance of hydronephrosis in percutaneous nephrolithotomy operation

    Directory of Open Access Journals (Sweden)

    Mehmet Murat Rifaioğlu

    2013-09-01

    Full Text Available Objective: The aim of this study is to investigate the relationbetween hydronephrosis grade and preoperative,peroperative and postoperative data and to evaluate theclinical significance of hydronephrosis in percutaneousnephrolithotomy (PNL.Methods: One hundred and thirty-two patients who hadundergone PNL operation by same surgeon betweenFebruary 2009 and February 2013 were reviewed retrospectively.Patients’ characteristics, preoperative kidneystatus, operative data were investigated. Grade 1, 2 hydronephrosiswere determined as Group I, Grade 3, 4hydronephrosis were determined as Group II. Preoperative,peroperative and postoperative property differencesbetween groups were compared statistically. For the multivariateanalysis, logistic regression analysis was usedto determine independent predictors of hydronephrosis.Results: Patients mean age was 46.2±13.7 years (8-73.Operation mean time was 101(10-250 minutes. 56 and76 patients’ data were analyzed in Group I and GroupII, respectively. There was no difference in age, gender,BMI, and surgeon experience between groups. Droppingstone history in same kidney (p=0.012, stone diameter(p=0.022, the number of calyceal stones (p=0.005, presencestone in the other kidney (p=0.027, renal parenchymalthickness (p=0.026 and operation time (p=0.011had significantly in univariate analysis. In logistic regressionmodel, dropping stone history in the same kidney,the number of calyceal stones, presence stone in theother kidney and operation time had a relationship withhydronephrosis.Conclusion: In PNL, patients with low-grade hydronephrosismight have decreased complication rates dueto diminished operation time, which resulted in reducednumber of calyceal stones and stone size.Key words: Percutaneous nephrolithotomy, PNL, hydronephrosis,outcome

  15. Data report for the NRC/PNL Halden Assembly IFA-432

    International Nuclear Information System (INIS)

    Hann, C.R.; Bradley, E.R.; Cunningham, M.E.; Lanning, D.D.; Marshall, R.K.; Williford, R.E.

    1978-08-01

    The report presents the in-reactor data collected from the NRC/PNL Halden Assembly IFA-432 as a part of the program entitled ''Experimental Vertification of Steady State Fuel Codes,'' sponsored by the Fuel Behavior Research Branch of the USNRC. The purpose of this program is to reduce the uncertainties of calculating the thermal stored energy in an operating nuclear fuel rod. The report presents fuel centerline thermocouple readings, cladding elongation monitor readings, rod internal pressure readings, and neutron detector readings. The neutron detector readings were corrected to represent rod local powers at the thermocouple locations. These data are presented in the form of plots of the variables versus time during the portion of the irradiation period from December 1975 to January 1978. Also included are descriptions of the test rationale, assembly and rod designs, test facility, instrument array and calibration, and data processing methods. Topical reports discussing specific aspects and results of the data analysis are referenced. As of May 1978, the assembly burnup had reached its design goal of 20,000 MWd/MTM. However, it has been decided to leave the assembly in core to collect high burnup fission gas release data. The xenon-filled Rod 4 was replaced with the non-instrumented Rod 8 (Rod 1 design) after the first cycle. Six of the twelve original thermocouples, four of the six cladding elongation monitors, all SPND'S and all pressure transducers remain operable at this writing

  16. Waste tank vapor project: Vapor space characterization of waste tank 241-BY-104: Results from samples collected on June 24, 1994

    International Nuclear Information System (INIS)

    Clauss, T.W.; Ligotke, M.W.; McVeety, B.D.; Pool, K.H.; Lucke, R.B.; Fruchter, J.S.; Goheen, S.C.

    1994-11-01

    This report describes results of the analyses of tank-headspace samples taken from Hanford waste Tank 241-BY-104 (referred to as Tank BY-104) on June 24, 1994. The Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze inorganic and organic samples collected from the tank headspace. The sample job was designated S4019 and was performed by WHC on June 24, 1994 using the vapor sampling system (VSS). The results of the analyses are expected to be used in the determination of safety and toxicological issues related to the tank-headspace gas as described in the WHC report entitled Data Quality Objectives for Generic In-Tank Health and Safety Vapor Issue Resolution, WHC-SD-WM-DQO-002, Rev. 0. Sampling devices, including 16 sorbent trains (for inorganic analyses), and 5 SUMMA trademark canisters (for organic analyses), were supplied to the WHC sampling staff on June 20, 1994. Samples were taken (by WHC) on June 24. The samples were returned from the field on June 27. The inorganic samples delivered to PNL on chain-of-custody (COC) 006893 included 16 sorbent trains as described in Tables 2.2, 2.3, and 2.4. Additional inorganic blank spikes were obtained from related sample jobs. SUMMA trademark samples delivered to PNL on COC 006896 included one ambient air sample, one ambient-air sample through the sampling system, and three tank-headspace SUMMA trademark canister samples. The samples were inspected upon delivery to the 326/23B laboratory and logged into PNL laboratory record book 55408. Custody of the sorbent trains was transferred to PNL personnel performing the inorganic analysis and stored at refrigerated (≤10 degrees C) temperature until the time of analysis. Access to the 326/23B laboratory is limited to PNL personnel working on the waste-tank safety program

  17. Workplace air monitoring and sampling practices at DOE facilities

    International Nuclear Information System (INIS)

    Swinth, K.L.; Kenoyer, J.L.; Selby, J.M.

    1987-01-01

    The Pacific Northwest Laboratory (PNL) surveyed the current air monitoring and sampling practices at U.S. Department of Energy (DOE) facilities as a part of an air monitoring upgrade task. A comprehensive questionnaire was developed and distributed to DOE contractors through the DOE field offices. Twenty-six facilities returned a completed questionnaire. Questionnaire replies indicate a large diversity in air sampling and monitoring practices among DOE facilities. The differences among the facilities exist in monitoring and sampling instrumentation, procedures, calibration, analytical methods, detection levels, and action levels. Many of these differences could be attributed to different operational needs. 5 references, 2 figures, 2 tables

  18. The effect of Pro NanoLipospheres (PNL) formulation containing natural absorption enhancers on the oral bioavailability of delta-9-tetrahydrocannabinol (THC) and cannabidiol (CBD) in a rat model.

    Science.gov (United States)

    Cherniakov, Irina; Izgelov, Dvora; Domb, Abraham J; Hoffman, Amnon

    2017-11-15

    The lipophilic phytocannabinoids cannabidiol (CBD) and Δ 9 -tetrahydrocannabinol (THC) show therapeutic efficacy in various medical conditions. Both molecules are poorly water soluble and subjected to extensive first pass metabolism in the gastrointestinal tract, leading to a limited oral bioavailability of approximately 9%. We have developed an advanced lipid based Self-Emulsifying Drug Delivery System termed Advanced Pro-NanoLiposphere (PNL) pre-concentrate. The PNL is composed of lipid and emulsifying excipients of GRAS status and are known to increase solubility and reduce Phase I metabolism of lipophilic active compounds. Advanced PNLs are PNLs with an incorporated natural absorption enhancers. These molecules are natural alkaloids and phenolic compounds which were reported to inhibit certain phase I and phase II metabolism processes. Here we use piperine, curcumin and resveratrol to formulate the Advanced-PNL formulations. Consequently, we have explored the utility of these Advanced-PNLs on CBD and THC oral bioavailability. Oral administration of CBD-piperine-PNL resulted in 6-fold increase in AUC compared to CBD solution, proving to be the most effective of the screened formulations. The same trend was found in pharmacokinetic experiments of THC-piperine-PNL which resulted in a 9.3-fold increase in AUC as compared to THC solution. Our Piperine-PNL can be used as a platform for synchronized delivery of piperine and CBD or THC to the enterocyte site. This co-localization provides an increase in CBD and THC bioavailability by its effect at the pre-enterocyte and the enterocyte levels of the absorption process. The extra augmentation in the absorption of CBD and THC by incorporating piperine into PNL is attributed to the inhibition of Phase I and phase II metabolism by piperine in addition to the Phase I metabolism and P-gp inhibition by PNL. These novel results pave the way to utilize piperine-PNL delivery system for other poorly soluble, highly metabolized

  19. The pnk/pnl gene (ORF 86) of Autographa californica nucleopolyhedrovirus is a non-essential, immediate early gene.

    Science.gov (United States)

    Durantel, D; Croizier, L; Ayres, M D; Croizier, G; Possee, R D; López-Ferber, M

    1998-03-01

    Autographa californica nucleopolyhedrovirus (AcMNPV) ORF 86, located within the HindIII C fragment, potentially encodes a protein which shares sequence similarity with two T4 bacteriophage gene products, RNA ligase and polynucleotide kinase. This AcMNPV gene has been designated pnk/pnl but has yet to be assigned a function in virus replication. It has been classified as an immediate early virus gene, since the promoter was active in uninfected insect cells and mRNA transcripts were detectable from 4 to 48 h post-infection and in the presence of cycloheximide or aphidicolin in virus-infected cells. The extremities of the transcript have been mapped by primer extension and 3' RACE-PCR to positions -18 from the translational start codon and +15 downstream of the stop codon. The function of pnk/pnl was investigated by producing a recombinant virus (Acdel86lacZ) with the coding region replaced with that of lacZ. This virus replicated normally in Spodoptera frugiperda (Sf 21) cells, indicating that pnk/pnl is not essential for propagation in these cells. Virus protein production in Acdel86lacZ-infected Sf 21 cells also appeared to be unaffected, with normal synthesis of the IE-1, GP64, VP39 and polyhedrin proteins. Shut-down of host protein synthesis was not abolished in recombinant infection. When other baculovirus genomes were examined for the presence of pnk/pnl by restriction enzyme digestion and PCR, a deletion was found in AcMNPV 1.2, Galleria mellonella NPV (GmMNPV) and Bombyx mori NPV (BmNPV), suggesting that in many isolates this gene has either never been acquired or has been lost during genome evolution. This is one of the first baculovirus immediate early genes that appears to be nonessential for virus survival.

  20. Materials balance area Custodian Performance Evaluation Program at PNL

    International Nuclear Information System (INIS)

    Dickman, D.A.

    1991-07-01

    The material balance area (MBA) custodian has primary responsibility for control and accountability of nuclear material within an MBA. In this role, the custodian operates as an extension of the facility material control and accountability (MC ampersand A) organization. To effectively meet administrative requirements and protection needs, the custodian must be fully trained in all aspects of MC ampersand A related to the MBA, and custodian performance must be periodically evaluated. DOE Policy requires that each facility provide for a program which assures that each facility provide for a program which assures that personnel performing MC ampersand A functions are (1) trained and/or qualified to perform their duties and responsibilities and (2) knowledgeable of requirements and procedures related to their functions. The MBA Custodian Performance Evaluation Program at PNL uses a variety of assessment techniques to meet this goal, including internal and independent MBA audits, periodic custodian testing, conduct of limited scope performance tests, daily monitoring of MC ampersand A documentation, and reviewing custodian performance during physical inventories. The data collected from these sources is analyzed and incorporated into an annual custodian performance evaluation document, given to each custodian and line management. Development of this program has resulted in significantly improved custodian performance and a marked decrease in finding and observations identified during MBA audits

  1. Single-pass continuous-flow leach test of PNL 76-68 glass: some selected Bead Leach I results

    International Nuclear Information System (INIS)

    Coles, D.G.

    1981-01-01

    A single-pass continuous-flow leach test of PNL 76-68 glass beads (7 mm dia) was concluded after 420 days of uninterrupted operation. Variables included in the experimental matrix were flow-rate, leachant composition, and temperature. Analysis was conducted on all leachate samples for 237 Np and 239 Pu as well as a number of nonradioactive elements. Results indicated that flow-rate and leachant systematically affected the leach rate, but only slightly. Temperature effects were significant. Plutonium leach rate was lower at higher temperature suggesting that Pu sorption onto the beads was enhanced at the higher temperature. The range of leach rates for all analyzed elements (except Pu), at both temperature, at all three flow rates, and with all three leachant compositions varied only three orders of magnitude. The range of variables used in this experiment covered those expected in many proposed repository environments. The preliminary interpretation of the results also indicated that matrix dissolution may be the dominant leaching mechanism, at least for Np in bicarbonate leachant. Regardless of the leaching mechanism the importance of this study is that it bounds the effects of repository environments when the ground water is oxidizing and when it doesn't reach the waste form until the waste has cooled to ambient rock temperature

  2. Treatment of small lower pole calculi--SWL vs. URS vs. PNL?

    Science.gov (United States)

    Knoll, Thomas; Tasca, Andrea; Buchholz, Noor P

    2011-03-01

    According to current guideline recommendations extracorporeal shock wave lithotripsy (SWL) remains the first choice treatment for small and mid-sized renal calculi. However, the results of SWL treatment for lower pole stones can be disappointing whilst more invasive endoscopic modalities, such as flexible ureterorenoscopy (fURS) and percutaneous nephrolithotomy (PNL) are often considered more effective. This article summarizes a point-counterpoint discussion at the 9th eULIS symposium in Como, Italy, and discusses the potential advantages and disadvantages of the different therapeutic approaches.

  3. Validation of a novel cost effective easy to produce and durable in vitro model for kidney-puncture and PNL-Simulation.

    Science.gov (United States)

    Klein, Jan Thorsten; Rassweiler, Jens; Rassweiler-Seyfried, Marie-Claire Charlotte

    2018-03-29

    Nephrolithiasis is one of the most common diseases in urology. According to the EAU Guidelines, a percutaneous nephrolitholapaxy (PNL) is recommended when treating a kidney stone >2 cm. Nowadays PNL is performed even for smaller stones (PNL is the puncture of the planned site. PNL-novice surgeons need to practice this step in a safe environment with an ideal training model. We developed and evaluated a new, easy to produce, in-vitro model for the training of the freehand puncture of the kidney. Porcine kidneys with ureters were embedded in ballistic gel. Food coloring and preservative agent were added. We used the standard imaging modalities of X-ray and ultrasound to validate the training model. An additional new technique, the iPAD guided puncture, was evaluated. Five novices and three experts conducted 12 punctures for each imaging technique. Puncture time, radiation dose, and number of attempts to a successful puncture were measured. Mann-Whitney-U, Kruskal-Wallis, and U-Tests were used for statistical analyses. The sonographic guided puncture is slightly but not significantly faster than the fluoroscopic guided puncture and the iPAD assisted puncture. Similarly, the most experienced surgeon's time for a successful puncture was slightly less than that of the residents, and the experienced surgeons needed the least attempts to perform a successful puncture. In terms of radiation exposure, the residents had a significant reduction of radiation exposure compared to the experienced surgeons. The newly developed ballistic gel kidney-puncture model is a good training tool for a variety of kidney puncture techniques, with good content, construct, and face validity.

  4. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    International Nuclear Information System (INIS)

    Rathbone, Bruce A.

    2006-01-01

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at Hanford. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with 10 CFR 835, DOELAP, DOE-RL, ORP, PNSO, and Hanford contractor requirements. The dosimetry system is operated by PNNL's Hanford External Dosimetry Program which provides dosimetry services to all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. Rev. 0 marks the first revision to be released through PNNL's Electronic Records & Information Capture Architecture (ERICA) database

  5. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    Energy Technology Data Exchange (ETDEWEB)

    Rathbone, Bruce A.

    2005-02-25

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at Hanford. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with 10 CFR 835, DOELAP, DOE-RL, ORP, PNSO, and Hanford contractor requirements. The dosimetry system is operated by PNNL’s Hanford External Dosimetry Program which provides dosimetry services to all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. Rev. 0 marks the first revision to be released through PNNL’s Electronic Records & Information Capture Architecture (ERICA) database.

  6. Experience with fuel damage caused by abnormal conditions in handling and transporting operations

    International Nuclear Information System (INIS)

    Bailey, W.J.

    1983-01-01

    Pacific Northwest Laboratory (PNL) conducted a study to determine the expected condition of spent USA light-water reactor (LWR) fuel upon arrival at interim storage or fuel reprocessing facilities or, if fuel is declared a waste, at disposal facilities. Initial findings were described in an earlier PNL paper at PATRAM '80 and in a report. Updated findings are described in this paper, which includes an evaluation of information obtained from the literature and a compilation of cases of known or suspected damage to fuel as a result of handling and/or transporting operations. To date, PNL has evaluated 123 actual cases (98 USA and 25 non-USA). Irradiated fuel was involved in all but 10 of the cases. From this study, it is calculated that the frequency of unusual occurrences involving fuel damage from handling and transporting operations has been low. The damage that did occur was generally minor. The current base of experience with fuel handling and transporting operations indicates that nearly all of these unusual occurrences had only a minor or negligible effect on spent fuel storage facility operations

  7. Characterization of a low-level radioactive waste grout: Sampling and test results

    International Nuclear Information System (INIS)

    Martin, P.F.C.; Lokken, R.O.

    1992-12-01

    WHC manages and operates the grout treatment facility at Hanford as part of a DOE program to clean up wastes stored at federal nuclear production sites. PNL provides support to the grout disposal program through pilot-scale tests, performance assessments, and formulation verification activities. in 1988 and 1989, over one million gallons of a low-level radioactive liquid waste was processed through the facility to produce a grout waste that was then deposited in an underground vault. The liquid waste was phosphate/sulfate waste (PSW) generated in decontamination of the N Reactor. PNL sampled and tested the grout produced during the second half of the PSW campaign to support quality verification activities prior to grout vault closure. Samples of grout were obtained by inserting nested-tube samplers into the grout slurry in the vault. After the grout had cured, the inner tube of the sampler was removed and the grout samples extracted. Tests for compressive strength, sonic velocity, and leach testing were used to assess grout quality; results were compared to those from pilot-scale test grouts made with a simulated PSW. The grout produced during the second half of the PSW campaign exceeded compressive strength and leachability formulation criteria. The nested tube samplers were effective in collecting samples of grout although their use introduced greater variability into the compressive strength data

  8. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    Energy Technology Data Exchange (ETDEWEB)

    Rathbone, Bruce A.

    2010-04-01

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at the U.S. Department of Energy (DOE) Hanford site. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with requirements of 10 CFR 835, the DOE Laboratory Accreditation Program, the DOE Richland Operations Office, DOE Office of River Protection, DOE Pacific Northwest Office of Science, and Hanford’s DOE contractors. The dosimetry system is operated by the Pacific Northwest National Laboratory (PNNL) Hanford External Dosimetry Program which provides dosimetry services to PNNL and all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since its inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. The first revision to be released through PNNL’s Electronic Records & Information Capture Architecture database was designated Revision 0. Revision numbers that are whole numbers reflect major revisions typically involving significant changes to all chapters in the document. Revision

  9. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    Energy Technology Data Exchange (ETDEWEB)

    Rathbone, Bruce A.

    2011-04-04

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at the U.S. Department of Energy (DOE) Hanford site. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with requirements of 10 CFR 835, the DOE Laboratory Accreditation Program, the DOE Richland Operations Office, DOE Office of River Protection, DOE Pacific Northwest Office of Science, and Hanford’s DOE contractors. The dosimetry system is operated by the Pacific Northwest National Laboratory (PNNL) Hanford External Dosimetry Program which provides dosimetry services to PNNL and all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since its inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. The first revision to be released through PNNL’s Electronic Records & Information Capture Architecture database was designated Revision 0. Revision numbers that are whole numbers reflect major revisions typically involving significant changes to all chapters in the document. Revision

  10. Status of the USNRC/PNL Halden test IFA-432

    International Nuclear Information System (INIS)

    Bradley, E.R.; Cunningham, M.E.; Lanning, D.D.; Williford, R.E.

    1980-01-01

    The NRC/PNL fuel assembly IFA-432 began irradiation in December 1975 and as of January 1980 had reached an assembly average burnup of 2120 GJ/kgU (24.5 GWd/MTM). The rods in this assembly are heavily instrumented and this has allowed a fairly thorough analysis of fuel behavior. The emphasis of the analysis has been to evaluate the observed changes in thermal/mechanical behavior. These changes are related to estimates of fuel density changes, fission gas release, and fuel cracking and relocation. The following conclusions have been reached concerning the irradiation of IFA-432. Based on analysis of steady-state and transient thermal data, the fuel in all rods is extensively cracked and relocated. Significant reductions in the effective fuel thermal conductivity have been deduced from the analysis of the transient thermal data

  11. Assurance program for remedial action (APRA) microcomputer-operated bibliography management system

    International Nuclear Information System (INIS)

    Stenner, R.D.; Washburn, D.K.; Denham, D.H.

    1985-10-01

    Pacific Northwest Laboratory (PNL) provided technical assistance to the Office of Operational Safety (OOS) in developing their Assurance Program for Remedial Action (APRA). The APRA Bibliography Management System (BMS), a microcomputer-operated system designed to file, locate and retrieve project-specific bibliographic data, was developed to manage the documentation associated with APRA. The BMS uses APRABASE, a PNL-developed computer program written in dBASE II language, which is designed to operate using the commercially available dBASE II database software. The paper describes the APRABASE computer program, its associated subprograms, and the dBASE II APRA file. Although the BMS was designed to manage APRA-associated documents, it could be easily adapted for use in handling bibliographic data associated with any project

  12. Assurance Program for Remedial Action (APRA) microcomputer-operated bibliography management system

    International Nuclear Information System (INIS)

    Stenner, R.D.; Washburn, D.K.; Denham, D.H.

    1986-01-01

    Pacific Northwest Laboratory (PNL) provided technical assistance to the Office of Operational Safety (OOS) in developing their Assurance Program for Remedial Action (APRA). The APRA Bibliography Management System (BMS), a microcomputer-operated system designed to file, locate and retrieve project-specific bibliographic data, was developed to manage the documentation associated with APRA. The BMS uses APRABASE, a PNL-developed computer program written in dBASE II/sup (b)/ language, which is designed to operate using the commercially available dBASE II database software. This paper describes the APRABASE computer program, its associated subprograms, and the dBASE II APRA file. Although the BMS was designed to manage APRA-associated documents, it could be easily adapted for use in handling bibliographic data associated with any project

  13. Sampling Operations on Big Data

    Science.gov (United States)

    2015-11-29

    gories. These include edge sampling methods where edges are selected by a predetermined criteria; snowball sampling methods where algorithms start... Sampling Operations on Big Data Vijay Gadepally, Taylor Herr, Luke Johnson, Lauren Milechin, Maja Milosavljevic, Benjamin A. Miller Lincoln...process and disseminate information for discovery and exploration under real-time constraints. Common signal processing operations such as sampling and

  14. Validation of MATRA-S Low Flow Predictions Using PNL 2x6 Mixed Convection Test

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Kyong-Won; Kwon, Hyuk; Kim, Seong-Jin; Hwang, Dae-Hyun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The MATRA-S, a subchannel analysis code has been used to thermal-hydraulic design of SMART core. As the safety enhancement is getting important more and more, some features of the MATRA-S code are required to be validated in order to be applied to nonnominal operating conditions in addition to its applicability to reactor design under normal operating conditions. The MATRA-S code has two numerical schemes, SCHEME for implicit application and XSCHEM for explicit one. The implicit scheme had been developed under assumptions that the axial flow is larger enough than the crossflow. Under certain conditions, especially low flow and low pressure operating conditions, this implicit SCHEME oscillates or becomes unstable numerically and then MATRA-S fails to obtain good solution. These demerits were known as common in implicit schemes of many COBRA families. Efforts have been exerted to resolve these limitations in SCHEME of the MATRA-S such as a once through marching scheme against the multi-pass marching scheme and an adaptive multi-grid method. These remedies can reduce the numerically unstable range for SCHEME but some unstable regions still remain. The XSCHEM, an explicit scheme of MATRA-S was validated using the PNL 2x6 rod bundle flow transient test. The explicit scheme agreed with implicit scheme for steady state calculations. And it showed its capability to predict low flow conditions such as negative flow and recirculation flow.

  15. Supplement to safety analysis report. 306-W building operations safety requirement

    International Nuclear Information System (INIS)

    Richey, C.R.

    1979-08-01

    The operations safety requirements (OSRs) presented in this report define the conditions, safe boundaries, and management control needed for safely conducting operations with radioactive materials in the Pacific Northwest Laboratory (PNL) 306-W building. The safety requirements are organized in five sections. Safety limits are safety-related process variables that are observable and measurable. Limiting conditions cover: equipment and technical conditions and characteristics of the facility and operations necessary for continued safe operation. Surveillance requirements prescribe the requirements for checking systems and components that are essential to safety. Equipment design controls require that changes to process equipment and systems be independently checked and approved to assure that the changes will have no adverse effect on safety. Administrative controls describe and discuss the organization and administrative systems and procedures to be used for safe operation of the facility. Details of the implementation of the operations safety requirements are prescribed by internal PNL documents such as criticality safety specifications and radiation work procedures

  16. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    Energy Technology Data Exchange (ETDEWEB)

    Rathbone, Bruce A.

    2009-08-28

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at Hanford. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with 10 CFR 835, DOELAP, DOE-RL, ORP, PNSO, and Hanford contractor requirements. The dosimetry system is operated by PNNL’s Hanford External Dosimetry Program (HEDP) which provides dosimetry services to all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee (HPDAC) which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. The first revision to be released through PNNL’s Electronic Records & Information Capture Architecture (ERICA) database was designated Revision 0. Revision numbers that are whole numbers reflect major revisions typically involving changes to all chapters in the document. Revision numbers that include a decimal fraction reflect minor revisions, usually restricted to selected chapters or selected pages in the document.

  17. Ambient krypton-85 air sampling at Hanford

    International Nuclear Information System (INIS)

    Trevathan, M.S.; Price, K.R.

    1985-01-01

    In the fall of 1982, the Environmental Evaluations Section of Pacific Northwest Laboratory (PNL) initiated a network of continuous 85 Kr air samplers located on and around the Hanford Site. This effort was in response to the resumption of operations at a nuclear fuel reprocessing plant located onsite where 85 Kr was to be released during fuel dissolution. Preoperational data were collected using noble gas samplers designed by the Environmental Protection Agency-Las Vegas (EPA-LV). The samplers functioned erratically resulting in excessive maintenance costs and prompted a search for a new sampling system. State-of-the-art 85 Dr sampling methods were reviewed and found to be too costly, too complex and inappropriate for field application, so a simple bag collection system was designed and field tested. The system is composed of a reinforced, heavy plastic bag, connected to a variable flow pump and housed in a weatherproof enclosure. At the end of the four week sampling period the air in the bag is transferred by a compressor into a pressure tank for easy transport to the laboratory for analysis. After several months of operation, the air sampling system has proven its reliability and sensitivity to ambient levels of 85 Kr

  18. Ambient krypton-85 air sampling at Hanford

    International Nuclear Information System (INIS)

    Trevathan, M.S.; Price, K.R.

    1984-10-01

    In the fall of 1982, the Environmental Evaluations Section of Pacific Northwest Laboratory (PNL) initiated a network of continuous krypton-85 air samplers located on and around the Hanford Site. This effort was in response to the resumption of operations at a nuclear fuel reprocessing plant located onsite where krypton-85 was to be released during fuel dissolution. Preoperational data were collected using noble gas samplers designed by the Environmental Protection Agency-Las Vegas (EPA-LV). The samplers functioned erratically resulting in excessive maintenance costs and prompted a search for a new sampling system. State of the art krypton-85 sampling methods were reviewed and found to be too costly, too complex and inappropriate for field application, so a simple bag collection system was designed and field tested. The system is composed of a reinforced, heavy plastic bag, connected to a variable flow pump and housed in a weatherproof enclosure. At the end of the four week sampling period the air in the bag is transferred by a compressor into a pressure tank for easy transport to the laboratory for analysis. After several months of operation, the air sampling system has proven its reliability and sensitivity to ambient levels of krypton-85. 3 references, 3 figures, 1 table

  19. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1993-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). Samples are routinely collected and analyzed to determine the quality of air, surface water, ground water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Drinking Water Project, and Ground-Water Surveillance Project.

  20. Waste tank vapor project: Vapor characterization of Tank 241-C-103: Data report for OVS samples collected from Sample Job 7b, Parts I and II, received 5/18/94 and 5/24/94

    International Nuclear Information System (INIS)

    Clauss, T.R.; Edwards, J.A.; Fruchter, J.S.

    1994-09-01

    On 5/18/94, Westinghouse Hanford Company (WHC) delivered samples to Pacific Northwest Laboratory (PNL) that were collected from waste Tank 241-C-103 on 5/16/94. These samples were from Sample Job (SJ) 7b, Part 1. On 5/24/94, WHC delivered samples to PNL that were collected from waste Tank 241-C-103 on 5/18/94. These samples were from SJ7b, Part 2. A summary of data derived from the sampling of waste Tank 241-C-103 for gravimetric (H 2 O) and normal paraffin hydrocarbon (NPH) concentrations are shown for SJ7b. Gravimetric analysis was performed on the samples within 24 hours of receipt by PNL. The NPH concentration of 10 samples collected for Part 1 was slightly higher than the average concentration for 15 samples collected in Part 2, 812 (± 133) mg/m 3 and 659 (± 88) mg/m 3 , respectively. The higher concentrations measured in Part 1 samples may be because the samples in Part 1 were collected at a single level, 0.79 meters above the air-liquid interface. Part 2 samples were collected at three different tank levels, 0.79, 2.92, and 5.05 m above the air-liquid interface. In Part 2, the average NPH concentrations for 5 samples collected at each of three levels was similar: 697 (60) mg/m 3 at the low level, 631 (51) mg/m 3 at the mid level, and 651 (134) mg/m 3 at the high level. It is important to note that the measured tridecane to dodecane concentration remained constant in all samples collected in Parts 1 and 2. That ratio is 1.2 ± 0.05. This consistent ratio indicates that there were no random analytical biases towards either compound

  1. Leach testing of SYNROC and glass samples at 85 and 200/degree/C

    International Nuclear Information System (INIS)

    Oversby, V.M.; Ringwood, A.E.

    1981-01-01

    Leach tests were conducted on 0.5 g disc samples of SYNROC and two glass types using distilled water at 85 and 200/degree/C. No leaching was detected for SYNROC at either temperature. Thus, the upper limit on leach rate for SYNROC is <0.005 g/m/sup 2/d. Waste glass PNL 76-68 had leach rates of 1.4 g/m/sup 2/ d at 85/degree/C and 8.9 g/m/sup 2/ d at 200/degree/C, while 73-1 glass frit had a leach rate of 41 g/m/sup 2/ d at 200/degree/C. The leach tests were repeated in the presence of rock powders. Again, no leaching was measurable for SYNROC. PNL 76-68 glass had leach rates between 4 and 23 g/m/sup 2/ d at 200/degree/C and 73-1 frit leached at rates between 29 and 176 g/m/sup 2/ d at 200/degree/C. Tests were also conducted on crushed glass samples (PNL 76-68, 100-200 /mu/m size fraction). Bulk leach rates were calculated based on measurement of Ca, Cs, and U in the leach solutions. The results of the leach tests show that SYNROC is several orders of magnitude more resistant to leaching than glass

  2. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    International Nuclear Information System (INIS)

    Rathbone, Bruce A.

    2007-01-01

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at Hanford. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with 10 CFR 835, DOELAP, DOE-RL, ORP, PNSO, and Hanford contractor requirements. The dosimetry system is operated by PNNL's Hanford External Dosimetry Program (HEDP) which provides dosimetry services to all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee (HPDAC) which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. Rev. 0 marks the first revision to be released through PNNL's Electronic Records and Information Capture Architecture (ERICA) database. Revision numbers that are whole numbers reflect major revisions typically involving changes to all chapters in the document. Revision numbers that include a decimal fraction reflect minor revisions, usually restricted to selected chapters or selected pages in the document. Revision Log: Rev. 0 (2/25/2005) Major revision and expansion. Rev. 0.1 (3/12/2007) Minor

  3. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    Energy Technology Data Exchange (ETDEWEB)

    Rathbone, Bruce A.

    2007-03-12

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at Hanford. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with 10 CFR 835, DOELAP, DOE-RL, ORP, PNSO, and Hanford contractor requirements. The dosimetry system is operated by PNNL’s Hanford External Dosimetry Program (HEDP) which provides dosimetry services to all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee (HPDAC) which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. Rev. 0 marks the first revision to be released through PNNL’s Electronic Records & Information Capture Architecture (ERICA) database. Revision numbers that are whole numbers reflect major revisions typically involving changes to all chapters in the document. Revision numbers that include a decimal fraction reflect minor revisions, usually restricted to selected chapters or selected pages in the document. Revision Log: Rev. 0 (2/25/2005) Major revision and expansion. Rev. 0.1 (3/12/2007) Minor

  4. Hanford high level waste: Sample Exchange/Evaluation (SEE) Program

    International Nuclear Information System (INIS)

    King, A.G.

    1994-08-01

    The Pacific Northwest Laboratory (PNL)/Analytical Chemistry Laboratory (ACL) and the Westinghouse Hanford Company (WHC)/Process Analytical Laboratory (PAL) provide analytical support services to various environmental restoration and waste management projects/programs at Hanford. In response to a US Department of Energy -- Richland Field Office (DOE-RL) audit, which questioned the comparability of analytical methods employed at each laboratory, the Sample Exchange/Exchange (SEE) program was initiated. The SEE Program is a selfassessment program designed to compare analytical methods of the PAL and ACL laboratories using sitespecific waste material. The SEE program is managed by a collaborative, the Quality Assurance Triad (Triad). Triad membership is made up of representatives from the WHC/PAL, PNL/ACL, and WHC Hanford Analytical Services Management (HASM) organizations. The Triad works together to design/evaluate/implement each phase of the SEE Program

  5. ICP/AES radioactive sample analyses at Pacific Northwest Laboratory

    International Nuclear Information System (INIS)

    Matsuzaki, C.L.; Hara, F.T.

    1986-03-01

    Inductively coupled argon plasma atomic emission spectroscopy (ICP/AES) analyses of radioactive materials at Pacific Northwest Laboratory (PNL) began about three years ago upon completion of the installation of a modified Applied Research Laboratory (ARL) 3560. Funding for the purchase and installation of the ICP/AES was provided by the Nuclear Waste Materials Characterization Center (MCC) established at PNL by the Department of Energy in 1979. MCC's objective is to ensure that qualified materials data are available on waste materials. This paper is divided into the following topics: (1) Instrument selection considerations; (2) initial installation of the simultaneous system with the source stand enclosed in a 1/2'' lead-shielded glove box; (3) retrofit installation of the sequential spectrometer; and (4) a brief discussion on several types of samples analyzed. 1 ref., 7 figs., 1 tab

  6. MELCOR 1.8.1 assessment: PNL Ice Condenser Aerosol Experiments

    International Nuclear Information System (INIS)

    Gross, R.J.

    1993-06-01

    The MELCOR code was used to simulate PNL's Ice Condenser Experiments 11-6 and 16-11. In these experiments, ZnS was injected into a mixing chamber, and the combined steam/air/aerosol mixture flowed into an ice condenser which was l4.7m tall. Experiment 11-6 was a low flow test; Experiment l6-1l was a high flow test. Temperatures in the ice condenser region and particle retention were measured in these tests. MELCOR predictions compared very well to the experimental data. The MELCOR calculations were also compared to CONTAIN code calculations for the same tests. A number of sensitivity studies were performed. It as found that simulation time step, aerosol parameters such as the number of MAEROS components and sections used and the particle density, and ice condenser parameters such as the energy capacity of the ice, ice heat transfer coefficient multiplier, and ice heat structure characteristic length all could affect the results. Thermal/hydraulic parameters such as control volume equilibrium assumptions, flow loss coefficients, and the bubble rise model were found to affect the results less significantly. MELCOR results were not machine dependent for this problem

  7. Agreement between pre-operative and intra-operative bacteriological samples in 85 chronic peri-prosthetic infections.

    Science.gov (United States)

    Matter-Parrat, V; Ronde-Oustau, C; Boéri, C; Gaudias, J; Jenny, J-Y

    2017-04-01

    Whether pre-operative microbiological sampling contributes to the management of chronic peri-prosthetic infection remains controversial. We assessed agreement between the results of pre-operative and intra-operative samples in patients undergoing single-stage prosthesis exchange to treat chronic peri-prosthetic infection. Agreement between pre-operative and intra-operative samples exceeds 75% in patients undergoing single-stage exchange of a hip or knee prosthesis to treat chronic peri-prosthetic infection. This single-centre retrospective study included 85 single-stage prosthesis exchange procedures in 82 patients with chronic peri-prosthetic infection at the hip or knee. Agreement between pre-operative and intra-operative sample results was evaluated. Changes to the initial antibiotic regimen made based on the intra-operative sample results were recorded. Of 149 pre-operative samples, 109 yielded positive cultures, in 75/85 cases. Of 452 intra-operative samples, 354 yielded positive cultures, in 85/85 cases. Agreement was complete in 54 (63%) cases and partial in 9 (11%) cases; there was no agreement in the remaining 22 (26%) cases. The complete agreement rate was significantly lower than 75% (P=0.01). The initial antibiotic regimen was inadequate in a single case. Pre-operative sampling may contribute to the diagnosis of peri-prosthetic infection but is neither necessary nor sufficient to confirm the diagnosis and identify the causative agent. The spectrum of the initial antibiotic regimen cannot be safely narrowed based on the pre-operative sample results. We suggest the routine prescription of a probabilistic broad-spectrum antibiotic regimen immediately after the prosthesis exchange, even when a pathogen was identified before surgery. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  8. Operational air sampling report, July--December 1991

    International Nuclear Information System (INIS)

    Lyons, C.L.

    1992-11-01

    Air sampling is one of the more useful ways of assessing the effectiveness of operational radiation safety programs at the Nevada Test Site (NTS). Air sampling programs document NTS airborne radionuclide concentrations in various work locations and environments. These concentrations generally remain well below the Derived Air Concentration (DAC) values prescribed by the Department of Energy (DOE 5480.11, Attachment 1) or the Derived Concentration Guide (DCG) values prescribed by the Department of Energy DOE 5400.5, Chapter Ill. The Defense Nuclear Agency (DNA) tunnel complexes, Area 12 Test Support Compound and the Area 6 Decontamination Pad and Laundry air sampling programs are summarized in this report. Evaluations are based on Analytical Services Department (ASD) Counting Laboratory analyses and Health Protection Department (HPD)/Radiological Field Operations Section (RFOS) radiation protection technician's (RPT) or health physicists' calculations for air samples collected July 1 through December 31, 1991. Of the NTS operational air sampling programs in the tunnel complexes, the initial mining and event reentry and recovery operations represent the only real airborne radioactive inhalation potentials to personnel. Monthly filter and scintillation cell samples were taken and counted in RDA-200 Radon Detectors to document working levels of radon/thoron daughters and picocurie/liter (PCVL) concentrations of radon gas. Weekly Drierite samples for tritium analysis were taken in the active tunnel complexes to document any changes in normal background levels or reentry drifts as they are advanced toward ground zero (GZ) areas. Underground water sources are considered primary transporters of tritium from old event areas

  9. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    Energy Technology Data Exchange (ETDEWEB)

    Rathbone, Bruce A.

    2010-01-01

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at Hanford. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with 10 CFR 835, DOELAP, DOE-RL, ORP, PNSO, and Hanford contractor requirements. The dosimetry system is operated by PNNL’s Hanford External Dosimetry Program (HEDP) which provides dosimetry services to all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee (HPDAC) which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since its inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. The first revision to be released through PNNL’s Electronic Records & Information Capture Architecture (ERICA) database was designated Revision 0. Revision numbers that are whole numbers reflect major revisions typically involving significant changes to all chapters in the document. Revision numbers that include a decimal fraction reflect minor revisions, usually restricted to selected chapters or selected pages in the document. Maintenance and distribution of controlled hard copies of the

  10. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L E

    1992-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Ground-Water Monitoring Project. Samples for radiological analyses include Air-Particulate Filter, gases and vapor; Water/Columbia River, Onsite Pond, Spring, Irrigation, and Drinking; Foodstuffs/Animal Products including Whole Milk, Poultry and Eggs, and Beef; Foodstuffs/Produce including Leafy Vegetables, Vegetables, and Fruit; Foodstuffs/Farm Products including Wine, Wheat and Alfalfa; Wildlife; Soil; Vegetation; and Sediment. Direct Radiation Measurements include Terrestrial Locations, Columbia River Shoreline Locations, and Onsite Roadway, Railway and Aerial, Radiation Surveys.

  11. Data quality objectives for Ion Exchange Module (IXM) disposition

    International Nuclear Information System (INIS)

    Choi, I.

    1995-01-01

    This Data Quality Objective (DQO) document presents the data needs and accuracy requirements for sampling ion exchange modules at the K Basins, 100 K Area, to determine if there is a hydrogen gas buildup within the modules. This document was produced by PNL, with the assistance of Neptune and Associates, and was partly funded (for facilitator) by DOE-HQ as a demonstration DQO for EM activities. PNL involved a number of PNL, WHC and support contract staff (including external technical consultants) in meetings to define the data needed, along with the necessary accuracy, to resolve issues associated with hydrogen accumulation in Ion Exchange Modules (IXMS) that were generated prior to July 1994 and only have one nuc-fil vent. IXMs generated after July 1994 have multiple nuc-fil vents and do not require sampling. PNL transmitted this DQO to WHC on January 31, 1995. This Supporting Document is to assure that the document is captured into the document retrieval system. WHC review focused on the acceptability of the technical conclusions such that the data collected will meet minimum operational, safety and environmental needs

  12. Microcomputer simulation model for facility performance assessment: a case study of nuclear spent fuel handling facility operations

    International Nuclear Information System (INIS)

    Chockie, A.D.; Hostick, C.J.; Otis, P.T.

    1985-10-01

    A microcomputer based simulation model was recently developed at the Pacific Northwest Laboratory (PNL) to assist in the evaluation of design alternatives for a proposed facility to receive, consolidate and store nuclear spent fuel from US commercial power plants. Previous performance assessments were limited to deterministic calculations and Gantt chart representations of the facility operations. To insure that the design of the facility will be adequate to meet the specified throughput requirements, the simulation model was used to analyze such factors as material flow, equipment capability and the interface between the MRS facility and the nuclear waste transportation system. The simulation analysis model was based on commercially available software and application programs designed to represent the MRS waste handling facility operations. The results of the evaluation were used by the design review team at PNL to identify areas where design modifications should be considered. 4 figs

  13. Operability test procedure for PFP wastewater sampling facility

    International Nuclear Information System (INIS)

    Hirzel, D.R.

    1995-01-01

    Document provides instructions for performing the Operability Test of the 225-WC Wastewater Sampling Station which monitors the discharge to the Treated Effluent Disposal Facility from the Plutonium Finishing Plant. This Operability Test Procedure (OTP) has been prepared to verify correct configuration and performance of the PFP Wastewater sampling system installed in Building 225-WC located outside the perimeter fence southeast of the Plutonium Finishing Plant (PFP). The objective of this test is to ensure the equipment in the sampling facility operates in a safe and reliable manner. The sampler consists of two Manning Model S-5000 units which are rate controlled by the Milltronics Ultrasonic flowmeter at manhole No.C4 and from a pH measuring system with the sensor in the stream adjacent to the sample point. The intent of the dual sampling system is to utilize one unit to sample continuously at a rate proportional to the wastewater flow rate so that the aggregate tests are related to the overall flow and thereby eliminate isolated analyses. The second unit will only operate during a high or low pH excursion of the stream (hence the need for a pH control). The major items in this OTP include testing of the Manning Sampler System and associated equipment including the pH measuring and control system, the conductivity monitor, and the flow meter

  14. The influence of percutaneous nephrolithotomy on human systemic stress response, SIRS and renal function.

    Science.gov (United States)

    Shen, Pengfei; Wei, Wuran; Yang, Xiaochun; Zeng, Hao; Li, Xiong; Yang, Jie; Wang, Jia; Huang, Jiaoti

    2010-10-01

    The objective of this study is to investigate the influences of percutaneous nephrolithotomy (PNL) and open surgery nephrolithotomy on the systemic stress response, SIRS and renal function. Forty patients with kidney calculi were enrolled in the study. Twenty cases were randomized to the PNL group and the other twenty cases to the open surgery group. Levels of C-reactive protein (CRP), interleukin-6(IL-6), β(2)-microglobulin (β(2)-MG), respiration rate, heart rate, body temperature and white blood cell counts were examined. CRP and IL-6 were measured in all patients pre-operatively and on post-operative days 1, 3 and 6, respectively. There was significant difference in their pre- and post-operation levels (P PNL group and 12 cases in open surgery group; there was significant difference between the two groups (P 0.05). Urine β(2)-MG levels were also measured. There was significant difference between pre- and the first day post-PNL (P PNL (P > 0.05). There was significant difference between pre- and first and third day post-open surgery (P 0.05). There was significant difference between two groups at the first, third and sixth days (P PNL group and open surgery group to some extent. The degree of stress response of PNL is lower than that of open surgery, proving the advantages of PNL with reference to serum immunology. There were cases in both the groups with SIRS, but the degree of SIRS in PNL group was lesser than the other group. Both the groups have no obvious effect on glomerular filtration function after operation and have effect on renal tubular reabsorption in the early stage after operation; but the recovery of the PNL group is faster than the open surgery group. It is thus shown that PNL is much safer and more feasible and has lesser effect on renal function.

  15. 30 CFR 90.209 - Respirable dust samples; transmission by operator.

    Science.gov (United States)

    2010-07-01

    ... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.209 Respirable dust samples; transmission by operator. (a) The operator shall transmit within 24 hours after the end of the sampling shift all samples...

  16. Percutaneous nephrolithotomy in very elderly patients (Age 75 and Over

    Directory of Open Access Journals (Sweden)

    Hüseyin Çelik

    2015-12-01

    Full Text Available Objective: Percutaneous nephrolithotomy (PNL is a minimally invasive method used safely in surgical treatment of kidney stones in the world. The first PNL surgery performed in our clinic in March 1998 and first PNL surgery was performed in June 2000 over the age of seventy which was bilaterally side. In our study, PNL operations performed for 75 years and older patients were examined. Methods: PNL operations were performed under the general anesthesia. After cystoscopy in the supine position, ureteral catheter was inserted accompanied by C-arm fluoroscopy. Afterwards, patients were taken prone position then we entered into the kidney with a metal needle with fluoroscopic on. We dilated the entrance with Amplatzer renal dilatators set until the 30 F. After the procedure, the nephrostomy catheter was placed in the renal sheath. 4 mm residual fragments after the PNL operation were accepted as clinically insignificant stone residues (CIRF. Results: 3003 PNL procedures were performed between dates March 1998 - December 2014 in total 16 years. 28 patients of total were 75 years and over. 29 PNL surgeries performed to these patients, including one bilateral PNL procedure. Mean age was 79.36 years (75-88. Twenty (74% of the patients were concluded stone free. 2 patients had tubeless PNL surgery. There was no another complication. Conclusion: PNL is a minimally invasive method has became advantageous according to open surgery because of higher safety, lower complication rates, shorter hospitalization stay, more patient comfort and higher stone free rates. PNL is a safe and effective method in the surgical treatment of urinary tract stone diseases.

  17. Tank 241-C-101 tank characterization plan

    International Nuclear Information System (INIS)

    Schreiber, R.D.

    1994-01-01

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, WHC 222-S Laboratory, and PNL 325 Analytical Chemistry Laboratory. The scope of this plan is to provide guidance for the sampling and analysis of samples from tank 241-C-101

  18. Tank 241-U-111 tank characterization plan

    International Nuclear Information System (INIS)

    Carpenter, B.C.

    1995-01-01

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, Oak Ridge National Laboratory, and PNL tank vapor program. The scope of this plan is to provide guidance for the sampling and analysis of vapor samples from tank 241-U-111

  19. Tank 241-C-105 tank characterization plan

    International Nuclear Information System (INIS)

    Schreiber, R.D.

    1994-01-01

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, WHC 222-S Laboratory, and PNL 325 Analytical Chemistry Laboratory. The scope of this plan is to provide guidance for the sampling and analysis of samples from tank 241-C-105

  20. Tank 241-BY-106 tank characterization plan

    International Nuclear Information System (INIS)

    Schreiber, R.D.

    1995-01-01

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, PNL 325 Analytical Chemistry Laboratory, and WHC 222-S Laboratory. The scope of this plan is to provide guidance for the sampling and analysis of samples for tank 241-BY-106

  1. Tank 241-BX-104 tank characterization plan

    International Nuclear Information System (INIS)

    Carpenter, B.C.

    1994-01-01

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, Oak Ridge National Laboratory, and PNL tank vapor program. The scope of this plan is to provide guidance for the sampling and analysis of vapor samples from tank 241-BX-104

  2. Tank 241-AP-107 tank characterization plan

    International Nuclear Information System (INIS)

    Schreiber, R.D.

    1994-01-01

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, WHC 222-S Laboratory, and PNL 325 Analytical Chemistry Laboratory. The scope of this plan is to provide guidance for the sampling and analysis of samples from tank 241-AP-107

  3. Tank 241-AX-104 tank characterization plan

    International Nuclear Information System (INIS)

    Sathyanarayana, P.

    1994-01-01

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, WHC 222-S Laboratory, and PNL 325 Analytical Chemistry Laboratory. The scope of this plan is to provide guidance for the sampling and analysis of auger samples from tank 241-AX-104

  4. Tank 241-AX-102 tank characterization plan

    International Nuclear Information System (INIS)

    Carpenter, B.C.

    1994-01-01

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, WHC 222-S Laboratory, and PNL 325 Analytical Chemistry Laboratory. The scope of this plan is to provide guidance for the sampling and analysis of auger samples from tank 241-AX-102

  5. Tank 241-U-103 tank characterization plan

    International Nuclear Information System (INIS)

    Carpenter, B.C.

    1995-01-01

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, Oak Ridge National Laboratory and PNL tank vapor program. The scope of this plan is to provide guidance for the sampling and analysis of vapor samples from tank 241-U-103

  6. Tank 241-TX-118 tank characterization plan

    International Nuclear Information System (INIS)

    Carpenter, B.C.

    1994-01-01

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, Oak Ridge National Laboratory, and PNL tank vapor program. The scope of this plan is to provide guidance for the sampling and analysis of vapor samples from tank 241-TX-118

  7. Tank 241-T-111 tank characterization plan

    International Nuclear Information System (INIS)

    Homi, C.S.

    1995-01-01

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, Oak Ridge National Laboratory, and PNL tank vapor program. The scope of this plan is to provide guidance for the sampling and analysis of vapor samples from tank 241-T-111

  8. Tank 241-TY-101 Tank Characterization Plan

    International Nuclear Information System (INIS)

    Homi, C.S.

    1995-01-01

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, Oak Ridge National Laboratory, and PNL tank vapor program. The scope of this plan is to provide guidance for the sampling and analysis of vapor samples from tank 241-TY-101

  9. Tank 241-C-103 tank characterization plan. Revision 1

    International Nuclear Information System (INIS)

    Schreiber, R.D.

    1995-01-01

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, WHC 222-S Laboratory, and PNL 325 Analytical Chemistry Laboratory. The scope of this plan is to provide guidance for the sampling and analysis of samples from tank 241-C-103

  10. Tank 241-T-107 tank characterization plan

    International Nuclear Information System (INIS)

    Homi, C.S.

    1995-01-01

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, Oak Ridge National Laboratory, and PNL tank vapor program. The scope of this plan is to provide guidance for the sampling and analysis of vapor samples from tank 241-T-107

  11. PNL... Una estrategia para la gestión de organizaciones de excelencia

    Directory of Open Access Journals (Sweden)

    Yanyn Rincón Quintero

    2006-09-01

    Full Text Available La presente investigación tiene por objeto analizar la relevancia que tiene el conocimiento y manejo efectivo de la Programación Neuro Lingística (PNL como estrategia de comunicación tanto para individuos para organizaciones; fundamentando su importancia en una combinación de técnica y arte sobre bases cognoscitivas; con miras a impulsar patrones de conducta idóneos para lograr objetivos y metas que orienten la autorrealización personal en organizaciones de excelencia generando la sinergia de equipos estratégicamente estructurado. El estudio se realizó a partir de una metodología descriptiva de carácter exploratorio; tipificada como no experimental, documental descriptiva; empleándose la observación descriptiva y el análisis de contenido como técnica para la recolección y tratamiento de información. Mediante el estudio se pudo concluir que la Programación Neuro Lingística genera en individuos y organizaciones el verdadero conocimiento y control de sus emociones impulsando un equilibrio en su comportamiento individual y organizacional.

  12. CRADA with United Solar Technologies and Pacific Northwest Laboratory (PNL-021): Thin film materialsfor low-cost high performance solar concentrators

    Science.gov (United States)

    Martin, P. M.; Affinito, J. D.; Gross, M. E.; Bennett, W. D.

    1995-03-01

    The objectives of this project were to develop and evaluate promising low-cost dielectric and polymer-protected thin-film reflective metal coatings to be applied to preformed continuously-curved solar reflector panels to enhance their solar reflectance, and to demonstrate protected solar reflective coatings on preformed solar concentrator panels. The opportunity for this project arose from a search by United Solar Technologies (UST) for organizations and facilities capable of applying reflective coatings to large preformed panels. PNL was identified as being uniquely qualified to participate in this collaborative project.

  13. Low crustal velocities and mantle lithospheric variations in southern Tibet from regional Pnl waveforms

    Science.gov (United States)

    Rodgers, Arthur J.; Schwartz, Susan Y.

    We report low average crustal P-wave velocities (5.9-6.1 km/s, Poisson's ratio 0.23-0.27, thickness 68-76 km) in southern Tibet from modelling regional Pnl waveforms recorded by the 1991-1992 Tibetan Plateau Experiment. We also find that the mantle lithosphere beneath the Indus-Tsangpo Suture and the Lhasa Terrane is shield-like (Pn velocity 8.20-8.25 km/s, lid thickness 80-140 km, positive velocity gradient 0.0015-0.0025 s-1). Analysis of relative Pn travel time residuals requires a decrease in the mantle velocities beneath the northern Lhasa Terrane, the Banggong-Nujiang Suture and the southern Qiangtang Terrane. Tectonic and petrologic considerations suggest that low bulk crustal velocities could result from a thick (50-60 km) felsic upper crust with vertically limited and laterally pervasive partial melt. These results are consistent with underthrusting of Indian Shield lithosphere beneath the Tibetan Plateau to at least the central Lhasa Terrane.

  14. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; operation; air... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate...

  15. Odor assessment for sewage sludge samples 300A01002

    International Nuclear Information System (INIS)

    Cash, D.B.; Molton, P.M.

    1976-12-01

    The use of radiation as a means of detoxifying sewage sludge as an alternate to the more conventional biological digestion treatment method was studied. A combination of gamma irradiation and heat (thermoradiation) treatment is being considered. In support of this effort, Battelle's Pacific Northwest Laboratories (PNL) were requested to assess the odor change of the sewage sludge, if any, that occurs with time after the samples were subjected to the treatment conditions. The test methods and results are presented

  16. Tank 241-TX-105 tank characterization plan

    International Nuclear Information System (INIS)

    Carpenter, B.C.

    1995-01-01

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, WHC 222-S Laboratory, Oak Ridge National Laboratory, and PNL tank vapor program. The scope of this plan is to provide guidance for the sampling and analysis of vapor samples from tank 241-TX-105

  17. When routine D-J implantation necessary during PNL?

    Science.gov (United States)

    Bayrak, Omer; Seckiner, Ilker; Erturhan, Sakip M; Bulut, Ersan; Demirbag, Asaf; Erbagci, Asaf

    2015-03-01

    We investigated the characteristics of patients who underwent Double-J catheter (D-J) implantation, the risk factors for prolonged urine leakage (PUL), and prediction of patients who require medical treatment. The data of 535 adult patients who underwent PNL due to kidney stone disease between January 2005 and December 2011 in our clinic were analyzed retrospectively. Patients were divided into 2 groups: Group 1 (n=77) (14.39%) included patients with Double-J catheter due to prolonged (> 24 h) urinary leakage and Group 2 (n=458) (85.61%) patients without urinary leakage. The mean stone burden was 951.94 ± 539.09 mm2 in Group 1, and 676.35 ±296.65 mm2 in Group 2 (p<0.05). DJ catheter was implanted in 11.33% of the patients with stone burden below 1000 mm2 versus in 51.21% of the patients with stone burden above 1000 mm2. In Group 1, the number of patients with two or more accesses performed was 18.18, whereas in Group 2 it was 8.5% (p<0.05). Among all patients, DJ implantation was performed in 13.07% of patients with a single access versus 26.41% of patients with two or more accesses. Also, DJ catheter was implanted in 41.46%of patients with residual stones versus 12.14% of stone-free patients. Three patients with stone burden above 1000 mm2, two or more accesses, and residual stone, all of them required DJ implantation. DJ implantation due to PUL had approximately 5-fold increase stone burden above 1000 mm2, 2-fold increase in patients undergoing two or more access and 3-fold increase in patients with residual stones. Therefore, we think that the D-J implantation is highly advisable in case of a stone load above 1000 mm2, two or more accesses, and in patients with residual stones.

  18. Beyond prone position in percutaneous nephrolithotomy: a comprehensive review.

    Science.gov (United States)

    de la Rosette, Jean J M C H; Tsakiris, Peter; Ferrandino, Michael N; Elsakka, Ahmed M; Rioja, Jorge; Preminger, Glenn M

    2008-12-01

    Percutaneous nephrolithotomy (PNL) is traditionally performed with the patient in the prone position. To assess the efficacy and safety of the prone and supine positions, particularly in obese patients and in those with staghorn calculi. A Medline search was conducted for articles published during the last 10 yr related to PNL in the prone and supine positions. This search revealed 9 published studies for supine and 25 for prone PNL. None of the supine PNL studies reported visceral injuries, while transfusion rates were 0.0-9.4% and stone-free rates were 69.6-95.0%. One study of supine PNL evaluated a significant proportion of obese patients. Prone PNL studies in obese patients report transfusion rates of 3.2-8.8% and stone-free rates of 79.0-89.2%. In the only randomized study, excluding obese patients and staghorn calculi, operative time favors the supine position. A nonrandomized comparative study demonstrated similar complication rates with insignificant improvement in treatment success for supine PNL; however, when comparing series with similar proportions of staghorn calculi cases, there are slightly improved outcomes for prone PNL. Moreover, comparison of weighted means favors prone PNL. For obese patients and staghorn calculi, prone PNL appears to be associated with decreased operative times with similar bleeding rates and slightly better stone-free rates than supine PNL.

  19. [Clinical analysis of percutaneous nephrolithotomy for staghorn calculi with different stone branch number].

    Science.gov (United States)

    Qi, Shi-yong; Zhang, Zhi-hong; Zhang, Chang-wen; Liu, Ran-lu; Shi, Qi-duo; Xu, Yong

    2013-12-01

    To investigate the impact of staghorn stone branch number on outcomes of percutaneous nephrolithotomy (PNL). From January 2009 to January 2013, the 371 patients with staghorn stones who were referred to our hospital for PNL were considered for this study. All calculi were showed with CT 3-dimentional reconstruction (3-DR) imaging. The computerized database of the patients had been reviewed. Our exclusion criterion was patients with congenital renal anomalies, such as horse-shoe and ectopic kidneys. And borderline stones that branched to one major calyx only were also not included. From 3-DR images, the number of stone branching into minor renal calices was recorded. We made "3" as the branch breakdown between groups. And the patients were divided into four groups. The number of percutaneous tract, operative time, staged PNL, intra-operative blood loss, complications, stone clearance rate, and postoperative hospital day were compared. The 371 patients (386 renal units) underwent PNL successfully, included 144 single-tract PNL, 242 multi-tract PNL, 97 staged PNL. The average operative time was (100 ± 50) minutes; the average intra-operative blood loss was (83 ± 67) ml. The stone clearance rate were 61.7% (3 days) and 79.5% (3 months). The postoperative hospital stay was (6.9 ± 3.4) days. A significantly higher ratio of multi-tract (χ(2) = 212.220, P PNL (χ(2) = 49.679, P PNL for calculi with stone branch number ≥ 5. There was no statistically meaningful difference among the 4 groups based on Clavien complication system (P = 0.460). The possibility of multi-tract and staged PNL, lower rate of stone clearance and longer postoperative hospital day increase for staghorn calculi with stone branch number more than 5.

  20. ECIRS (Endoscopic Combined Intrarenal Surgery) in the Galdakao-modified supine Valdivia position: a new life for percutaneous surgery?

    Science.gov (United States)

    Cracco, Cecilia Maria; Scoffone, Cesare Marco

    2011-12-01

    Percutaneous nephrolithotomy (PNL) is still the gold-standard treatment for large and/or complex renal stones. Evolution in the endoscopic instrumentation and innovation in the surgical skills improved its success rate and reduced perioperative morbidity. ECIRS (Endoscopic Combined IntraRenal Surgery) is a new way of affording PNL in a modified supine position, approaching antero-retrogradely to the renal cavities, and exploiting the full array of endourologic equipment. ECIRS summarizes the main issues recently debated about PNL. The recent literature regarding supine PNL and ECIRS has been reviewed, namely about patient positioning, synergy between operators, procedures, instrumentation, accessories and diagnostic tools, step-by-step standardization along with versatility of the surgical sequence, minimization of radiation exposure, broadening to particular and/or complex patients, limitation of post-operative renal damage. Supine PNL and ECIRS are not superior to prone PNL in terms of urological results, but guarantee undeniable anesthesiological and management advantages for both patient and operators. In particular, ECIRS requires from the surgeon a permanent mental attitude to synergy, standardized surgical steps, versatility and adherence to the ongoing clinical requirements. ECIRS can be performed also in particular cases, irrespective to age or body habitus. The use of flexible endoscopes during ECIRS contributes to minimizing radiation exposure, hemorrhagic risk and post-PNL renal damage. ECIRS may be considered an evolution of the PNL procedure. Its proposal has the merit of having triggered the critical analysis of the various PNL steps and of patient positioning, and of having transformed the old static PNL into an updated approach.

  1. A prospective randomized study comparing percutaneous nephrolithotomy under combined spinal-epidural anesthesia with percutaneous nephrolithotomy under general anesthesia.

    Science.gov (United States)

    Singh, Vishwajeet; Sinha, Rahul Janak; Sankhwar, S N; Malik, Anita

    2011-01-01

    A prospective randomized study was executed to compare the surgical parameters and stone clearance in patients who underwent percutaneous nephrolithotomy (PNL) under combined spinal-epidural anesthesia (CSEA) versus those who underwent PNL under general anesthesia (GA). Between January 2008 to December 2009, 64 patients with renal calculi were randomized into 2 groups and evaluated for the purpose of this study. Group 1 consisted of patients who underwent PNL under CSEA and Group 2 consisted of patients who underwent PNL under GA. The operative time, stone clearance rate, visual pain analog score, mean analgesic dose and mean hospital stay were compared amongst other parameters. The difference between visual pain analog score after the operation and the dose of analgesic requirement was significant on statistical analysis between both groups. PNL under CSEA is as effective and safe as PNL under GA. Patients who undergo PNL under CESA require lesser analgesic dose and have a shorter hospital stay. Copyright © 2011 S. Karger AG, Basel.

  2. Mini vs standard percutaneous nephrolithotomy for renal stones: a comparative study.

    Science.gov (United States)

    ElSheemy, Mohammed S; Elmarakbi, Akram A; Hytham, Mohammed; Ibrahim, Hamdy; Khadgi, Sanjay; Al-Kandari, Ahmed M

    2018-03-16

    To compare the outcome of mini-percutaneous nephrolithotomy (Mini-PNL) versus standard-PNL for renal stones. Retrospective study was performed between March 2010 and May 2013 for patients treated by Mini-PNL or standard-PNL through 18 and 30 Fr tracts, respectively, using pneumatic lithotripsy. Semirigid ureteroscope (8.5/11.5 Fr) was used for Mini-PNL and 24 Fr nephroscope for standard-PNL. Both groups were compared in stone free rate(SFR), complications and operative time using Student-t, Mann-Whitney, Chi square or Fisher's exact tests as appropriate in addition to logistic regression analysis. P PNL (378) and standard-PNL (151) were nearly comparable in patients and stones criteria including stone burden (3.77 ± 2.21 vs 3.77 ± 2.43 cm 2 ; respectively). There was no significant difference in number of tracts or supracostal puncture. Mini-PNL had longer operative time (68.6 ± 29.09 vs 60.49 ± 11.38 min; p = 0.434), significantly shorter hospital stay (2.43 ± 1.46 vs 4.29 ± 1.28 days) and significantly higher rate of tubeless PNL (75.1 vs 4.6%). Complications were significantly higher in standard-PNL (7.9 vs 20.5%; p PNL (89.9 vs 96%; p = 0.022). This significant difference was found with multiple stones and large stone burden (> 2 cm 2 ), but the SFR was comparable between both groups with single stone or stone burden ≤ 2 cm. Logistic regression analysis confirmed significantly higher complications and SFR with standard-PNL but with significantly shorter operative time. Mini-PNL has significantly lower SFR when compared to standard-PNL (but clinically comparable) with markedly reduced complications and hospital stay. Most of cases can be performed tubeless. The significant difference in SFR was found with multiple stones or large stone burden (> 2 cm 2 ), but not with single stones or stone burden ≤ 2 cm 2 .

  3. Liquid Effluent Monitoring Program at the Pacific Northwest Laboratory

    International Nuclear Information System (INIS)

    Ballinger, M.Y.

    1995-05-01

    Pacific Northwest Laboratory (PNL) is conducting a program to monitor the waste water from PNL-operated research and development facilities on the Hanford Site. The purpose of the program is to collect data to assess administrative controls and to determine whether discharges to the process sewer meet sewer criteria. Samples have been collected on a regular basis from the major PNL facilities on the Hanford Site since March 1994. A broad range of analyses has been performed to determine the primary constituents in the liquid effluent. The sampling program is briefly summarized in the paper. Continuous monitoring of pH, conductivity, and flow also provides data on the liquid effluent streams. In addition to sampling and monitoring, the program is evaluating the dynamics of the waste stream with dye studies and is evaluating the use of newer technologies for potential deployment in future sampling/monitoring efforts. Information collected to date has been valuable in determining sources of constituents that may be higher than the Waste Acceptance Criteria (WAC) for the Treated Effluent Disposal Facility (TEDF). This facility treats the waste streams before discharge to the Columbia River

  4. Efficacy and safety of totally tubeless standard percutaneous nephrolithotomy in patients with kidney stones

    Directory of Open Access Journals (Sweden)

    Cemil Aydın

    2014-09-01

    Full Text Available Objective: Percutaneous nephrolithotomy (PNL is the first- line treatment for large and complex renal calculi. In this study, we aimed to compare the efficacy and safety of the totally tubeless PNL versus the standard PNL. Methods:Between January 2012 and July 2013, 73 selected patients were treated standard or totally tubeless PNL, nephrostomy tube and ureteral stent was not placed at the end of the operation in 35 (39.7% (Group 1 of them and 38 (43.1% (Group 2 patient underwent standard PNL. Stone disintegration was performed with a pneumatic lithotripter. We retrospectively compared patient and stone characteristics, operation time, duration of hospitalization, analgesia requirements, stone-free rate, operative findings, blood loss, and perioperative complications between two groups. Results:The mean operation time, excluding the preparation course, was 38,3±15,4 minutes vs 51,2±12,9 minutes and mean fluoroscopy time was 4,5±2,4 minutes vs 4,8±2,1 minutes, respectively. No significant intraoperative complication or indication additional access or second-look PNL due to residual stones was observed. In both groups none of the patients demonstrated a urinoma, hemorrhage or residual stones in postoperative ultrasonography and plain radiograph. Blood transfusion was needed only in a patient vs two patients for group 1 and 2, respectively. There were no significant differences in preoperative patient characteristics, postoperative complications between two groups, but the totally tubeless PNL group showed a shorter hospitalization and a lesser analgesic requirement compared with other group. Conclusion: Absence of the nephrostomy tube and ureteral stent may help in keeping the patient comfortable after the operation and reduction in the analgesia requirement and length of hospital stay. We believe totally tubeless PNL is safe and effective management option in properly selected cases.

  5. Review of ALARA plan for activities at the 105 K-East fuel storage basin

    International Nuclear Information System (INIS)

    Vargo, G.J.; Durham, J.S.; Hickey, E.E.; Stansbury, P.S.; Cicotte, G.R.

    1994-09-01

    As part of its ongoing efforts to reduce doses to workers to levels as low as reasonably achievable (ALARA), Westinghouse Hanford Company (WHC) tasked the Health Protection Department of the Pacific Northwest Laboratory (PNL) to review operations at the 105 K-East Fuel Storage Basin (105 K-East). This review included both routine operations and a proposed campaign to encapsulate N-Reactor fuel stored there. This report summarizes the results of PNL's reviews of policy, procedures, and practices for operations at 105 K-East as well as an evaluation of the major sources of occupational radiation exposures. Where possible, data previously collected by WHC and its predecessors were used. In addition, PNL staff developed a three-dimensional model of the radiological environment within 105 K-East to assess the relative contributions of different radiation sources to worker dose and to provide a decision tool for use in evaluating alternative methods of dose rate reduction. The model developed by PNL indicates that for most areas in the basin the primary source of occupational radiation exposure is the contaminated concrete surfaces of the basin near the waterline. Basin cooling water piping represents a significant source in a number of areas, particularly the Technical Viewing Pit. This report contains specific recommendations to reduce the impact of these sources of occupational radiation exposure in 105 K-East. Other recommendations to reduce doses to workers during activities such as filter changes and filter sampling are also included

  6. Experimental and Sampling Design for the INL-2 Sample Collection Operational Test

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Amidan, Brett G.; Matzke, Brett D.

    2009-02-16

    This report describes the experimental and sampling design developed to assess sampling approaches and methods for detecting contamination in a building and clearing the building for use after decontamination. An Idaho National Laboratory (INL) building will be contaminated with BG (Bacillus globigii, renamed Bacillus atrophaeus), a simulant for Bacillus anthracis (BA). The contamination, sampling, decontamination, and re-sampling will occur per the experimental and sampling design. This INL-2 Sample Collection Operational Test is being planned by the Validated Sampling Plan Working Group (VSPWG). The primary objectives are: 1) Evaluate judgmental and probabilistic sampling for characterization as well as probabilistic and combined (judgment and probabilistic) sampling approaches for clearance, 2) Conduct these evaluations for gradient contamination (from low or moderate down to absent or undetectable) for different initial concentrations of the contaminant, 3) Explore judgment composite sampling approaches to reduce sample numbers, 4) Collect baseline data to serve as an indication of the actual levels of contamination in the tests. A combined judgmental and random (CJR) approach uses Bayesian methodology to combine judgmental and probabilistic samples to make clearance statements of the form "X% confidence that at least Y% of an area does not contain detectable contamination” (X%/Y% clearance statements). The INL-2 experimental design has five test events, which 1) vary the floor of the INL building on which the contaminant will be released, 2) provide for varying the amount of contaminant released to obtain desired concentration gradients, and 3) investigate overt as well as covert release of contaminants. Desirable contaminant gradients would have moderate to low concentrations of contaminant in rooms near the release point, with concentrations down to zero in other rooms. Such gradients would provide a range of contamination levels to challenge the sampling

  7. Operability test report for core sample truck number one flammable gas modifications

    International Nuclear Information System (INIS)

    Akers, J.C.

    1997-01-01

    This report primarily consists of the original test procedure used for the Operability Testing of the flammable gas modifications to Core Sample Truck No. One. Included are exceptions, resolutions, comments, and test results. This report consists of the original, completed, test procedure used for the Operability Testing of the flammable gas modifications to the Push Mode Core Sample Truck No. 1. Prior to the Acceptance/Operability test the truck No. 1 operations procedure (TO-080-503) was revised to be more consistent with the other core sample truck procedures and to include operational steps/instructions for the SR weather cover pressurization system. A draft copy of the operations procedure was used to perform the Operability Test Procedure (OTP). A Document Acceptance Review Form is included with this report (last page) indicating the draft status of the operations procedure during the OTP. During the OTP 11 test exceptions were encountered. Of these exceptions four were determined to affect Acceptance Criteria as listed in the OTP, Section 4.7 ACCEPTANCE CRITERIA

  8. 30 CFR 90.210 - Respirable dust samples; report to operator.

    Science.gov (United States)

    2010-07-01

    ... MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.210 Respirable dust samples; report to operator. (a) The Secretary shall... for voiding any samples; and, (7) The Social Security Number of the part 90 miner. (b) Upon receipt...

  9. Trainee-Associated Factors and Proficiency at Percutaneous Nephrolithotomy

    Directory of Open Access Journals (Sweden)

    Seyed Mohammad Kazem Aghamir

    2017-09-01

    Full Text Available Percutaneous nephrolithotomy (PNL is a complicated procedure for urology trainees. This study was designed to investigate the effect of trainees’ ages and previous experience, as well as the number of operated cases, on proficiency at PNL by using patient outcomes. A cross sectional observational study was designed during a five-year period. Trainees in PNL fellowship programs were included. At the end of the program, the trainees’ performance in PNL was assessed regarding five competencies and scored 1-5. If the overall score was 4 or above, the trainee was considered as proficient. The trainees’ age at the beginning of the program and the years passed from their residency graduation were asked and recorded. Also, the number of PNL cases operated by each trainee was obtained via their logbooks. The age, years passed from graduation, and number of operated cases were compared between two groups of proficient and non-proficient trainees. Univariate and multivariate binary logistic regression analysis was applied to estimate the effect of aforementioned variables on the occurrence of the proficiency. Forty-two trainees were included in the study. The mean and standard deviation for the overall score were 3.40 (out of 5 and 0.67, respectively. Eleven trainees (26.2% recognized as proficient in performing PNL. Univariate regression analysis indicated that each of three variables (age, years passed from graduation and number of operated cases had statistically significant effect on proficiency. However, the multivariate regression analysis revealed that just the number of cases had significant effect on achieving proficiency. Although it might be assumed that trainees’ age negatively correlates with their scores, in fact, it is their amount of practice that makes a difference. A certain number of cases is required to be operated by a trainee in order to reach the desired competency in PNL.

  10. Trainee-Associated Factors and Proficiency at Percutaneous Nephrolithotomy.

    Science.gov (United States)

    Aghamir, Seyed Mohammad Kazem; Behtash, Negar; Hamidi, Morteza; Farahmand, Hasan; Salavati, Alborz; Mortaz Hejri, Sara

    2017-07-01

    Percutaneous nephrolithotomy (PNL) is a complicated procedure for urology trainees. This study was designed to investigate the effect of trainees' ages and previous experience, as well as the number of operated cases, on proficiency at PNL by using patient outcomes. A cross sectional observational study was designed during a five-year period. Trainees in PNL fellowship programs were included. At the end of the program, the trainees' performance in PNL was assessed regarding five competencies and scored 1-5. If the overall score was 4 or above, the trainee was considered as proficient. The trainees' age at the beginning of the program and the years passed from their residency graduation were asked and recorded. Also, the number of PNL cases operated by each trainee was obtained via their logbooks. The age, years passed from graduation, and number of operated cases were compared between two groups of proficient and non-proficient trainees. Univariate and multivariate binary logistic regression analysis was applied to estimate the effect of aforementioned variables on the occurrence of the proficiency. Forty-two trainees were included in the study. The mean and standard deviation for the overall score were 3.40 (out of 5) and 0.67, respectively. Eleven trainees (26.2%) recognized as proficient in performing PNL. Univariate regression analysis indicated that each of three variables (age, years passed from graduation and number of operated cases) had statistically significant effect on proficiency. However, the multivariate regression analysis revealed that just the number of cases had significant effect on achieving proficiency. Although it might be assumed that trainees' age negatively correlates with their scores, in fact, it is their amount of practice that makes a difference. A certain number of cases is required to be operated by a trainee in order to reach the desired competency in PNL.

  11. Modified totally tubeless percutaneous nephrolithotomy: Is it an effective and safe treatment option for renal and upper ureteral stones?

    Science.gov (United States)

    Chung, Ho Seok; Jung, Seung Il; Yu, Ho Song; Hwang, Eu Chang; Oh, Kyung Jin; Kwon, Dong Deuk; Park, Kwangsung

    2016-01-01

    We hypothesized that modified totally tubeless percutaneous nephrolithotomy (PNL) without indwelling ureteral stent would minimize postoperative discomfort without complications. To evaluate the safety, efficacy, and morbidity of standard, tubeless, and modified totally tubeless PNL as well as the usefulness of modified totally tubeless PNL. From November 2011 to February 2015, 211 patients who underwent PNL consecutively were enrolled in this study and divided into 3 groups (group 1: standard, group 2: tubeless, group 3: modified totally tubeless PNL). Patient and stone characteristics, operation time, hemoglobin change, length of hospitalization, stone-free rate, analgesic requirement, and perioperative complications were analyzed and compared among the 3 groups. There were no significant differences in preoperative patient characteristics among the three groups. In the postoperative analysis, the three groups had similar operation time, stone-free rate, perioperative fever and transfusion rate, but group 2 showed superior results in terms of length of hospitalization (p = 0.001). Group 2 and group 3 had a lower analgesic requirement (p = 0.010). Immediate postoperative hemoglobin change (p = 0.001) and tube site complications (p = 0.001) were more common in group 1. Modified totally tubeless PNL was not inferior in terms of postoperative outcomes and safety compared with the standard and tubeless PNL, and avoided the postoperative stent-related symptoms and cystoscopy for double-J stent removal. Modified totally tubeless PNL could be an alternative treatment of choice for management of renal or upper ureteral stones in selected patients.

  12. ПЕРКУТАННАЯ НЕФРОЛИТОТОМИЯ В ЛЕЧЕНИИ КРУПНЫХ И КОРАЛЛОВИДНЫХ КАМНЕЙ ПОЧЕК

    Directory of Open Access Journals (Sweden)

    2015-01-01

    Full Text Available Management of large and staghorn renal calculi is an actual urology problem. Authors analyzed 808 percutaneous nephrolithotomies (PNL, performed for 613 patients since 2010 to 2014. There were used most modern PNL procedures: multiple access, miniPNL, combined approach to kidney. Demonstrated high effectiveness of this method – 74% stone free rate, associated with low complication level for Clavien scale – 3 level – 5,6% of patients, 4 – 1,6%. No deaths and nephrectomies were observed. Procedures, which authors rated as optimizing treatment and decreasing complications, include miniPNL, tubeless PNL. Prone position is recommended as most comfortable. Puncture is performing using ultrasound probe, without adapter (free hand technic. Third part of all operations were done without previous retrograde ureter catheterizing, this trick allows do operation faster, decreases invasiveness and time of fluoroscopy. Optimal technic of access dilating was found using one or two shots Amplats sheath placement. Most dangerous complications are urosepsis and bleeding. 5 cases of arterio-venous fistula or pseudoaneurism were noticed, which are treated endovascular. PNL demonstrate well results and low complication level for treating of large and staghorn renal stones.

  13. Comparative Study between Standard and Totally Tubeless Percutaneous Nephrolithotomy.

    Science.gov (United States)

    Yun, Sung Il; Lee, Yoon Hyung; Kim, Jae Soo; Cho, Sung Ryong; Kim, Bum Soo; Kwon, Joon Beom

    2012-11-01

    Several recent studies have reported the benefits of tubeless percutaneous nephrolithotomy (PNL). Postoperatively, tubeless PNL patients have an indwelling ureteral stent placed, which is often associated with stent-related morbidity. We have performed totally tubeless (tubeless and stentless) PNL in which no nephrostomy tube or ureteral stent is placed postoperatively. We evaluated the safety, effectiveness, and feasibility of totally tubeless PNL. From March 2008 to February 2012, 57 selected patients underwent standard or totally tubeless PNL. Neither a nephrostomy tube nor a ureteral stent was placed in the totally tubeless PNL group. We compared patient and stone characteristics, operation time, length of hospitalization, analgesia requirements, stone-free rate, blood loss, change in creatinine, and perioperative complications between the standard and totally tubeless PNL groups. There were no significant differences in preoperative patient characteristics, postoperative complications, or the stone-free rate between the two groups, but the totally tubeless PNL group showed a shorter hospitalization and a lesser analgesic requirement compared with the standard PNL group. Blood loss and change in creatinine were not significantly different between the two groups. Totally tubeless PNL appears to be a safe and effective alternative for the management of renal stone patients and is associated with a decrease in length of hospital stay.

  14. Standard operating procedure for combustion of 14C - samples with OX-500 biological material oxidizer

    International Nuclear Information System (INIS)

    Nashriyah Mat.

    1995-01-01

    This procedure is for the purpose of safe operation of OX-500 biological material oxidizer. For ease of operation, the operation flow chart (including testing the system and sample combustion) and end of day maintenance flow chart were simplified. The front view, diagrams and switches are duly copied from operating manual. Steps on sample preparation are also included for biotic and a biotic samples. This operating procedure is subjected to future reviews

  15. Clinical efficacy, safety, and costs of percutaneous occlusive balloon catheter-assisted ureteroscopic lithotripsy for large impacted proximal ureteral calculi: a prospective, randomized study.

    Science.gov (United States)

    Qi, Shiyong; Li, Yanni; Liu, Xu; Zhang, Changwen; Zhang, Hongtuan; Zhang, Zhihong; Xu, Yong

    2014-09-01

    To evaluate the clinical efficacy, safety, and costs of percutaneous occlusive balloon catheter-assisted ureteroscopic lithotripsy (POBC-URSL) for large impacted proximal ureteral calculi. 156 patients with impacted proximal ureteral stones ≥1.5 cm in size were randomized to ureteroscopic lithotripsy (URSL), POBC-URSL, and percutaneous nephrolithotomy (PNL) group between May 2010 and May 2013. For URSL, the calculi were disintegrated with the assistance of anti-retropulsion devices. POBC-URSL was performed with the assistance of an 8F percutaneous occlusive balloon catheter. PNL was finished with the combination of an ultrasonic and a pneumatic lithotripter. A flexible ureteroscope and a 200 μm laser fiber were used to achieve stone-free status to a large extent for each group. Variables studied were mean operative time, auxiliary procedure, postoperative hospital stay, operation-related complications, stone clearance rate, and treatment costs. The mean lithotripsy time for POBC-URSL was shorter than URSL, but longer than PNL (42.6±8.9 minutes vs 66.7±15.3 minutes vs 28.1±6.3 minutes, p=0.014). The auxiliary procedure rate and postoperative fever rate for POBC-URSL were significantly lower than URSL and comparable to PNL (pPNL (98.1% vs 75.0% vs 96.2%, pPNL group and similar to URSL group (p=0.016, pPNL.

  16. Operational air sampling report, January--June 30, 1992

    International Nuclear Information System (INIS)

    Lyons, C.L.

    1992-09-01

    Nevada Test Site postshot and tunnel events generate beta/gamma fission products. The Reynolds Electrical ampersand Engineering Co., Inc. air sampling program is designed for measurement of these radionuclides at various facilities supporting these events. Monthly radon sampling is done for documentation of working levels in the tunnel complexes, which would be expected to hove the highest radon levels for on-site facilities. Out of a total of 281 air samples taken in the tunnel complexes, 25 showed airborne fission products with concentrations well below their respective Derived Air Concentrations (DAC). All of these were related to event reentry or mineback operations. Tritiated water vapor and radon levels were very similar to previously reported levels. The 975 air samples taken at the Area-6 decontamination bays and laundry were again well below any DAC calculation standard and negative for any airborne fission products from laboratory analyses

  17. Design/Operations review of core sampling trucks and associated equipment

    International Nuclear Information System (INIS)

    Shrivastava, H.P.

    1996-01-01

    A systematic review of the design and operations of the core sampling trucks was commissioned by Characterization Equipment Engineering of the Westinghouse Hanford Company in October 1995. The review team reviewed the design documents, specifications, operating procedure, training manuals and safety analysis reports. The review process, findings and corrective actions are summarized in this supporting document

  18. Pacific Northwest Laboratory facilities radionuclide inventory assessment CY 1992-1993

    International Nuclear Information System (INIS)

    Sula, M.J.; Jette, S.J.

    1994-09-01

    Assessments for evaluating compliance with airborne radionuclide emission monitoring requirements in the National Emission Standards for Hazardous Air Pollutants (NESHAPs - U.S. Code of Federal Regulations, Title 40 Part 61, Subparts H and I) were performed for 33 buildings at the U.S. Department of Energy's (DOE) Pacific Northwest Laboratory on the Hanford Site, and for five buildings owned and operated by Battelle, Pacific Northwest Laboratories in Richland, Washington. The assessments were performed using building radionuclide inventory data obtained in 1992 and 1993. Results of the assessments are summarized in Table S.1 for DOE-PNL buildings and in Table S.2 for Battelle-owned buildings. Based on the radionuclide inventory assessments, four DOE-PNL buildings (one with two emission points) require continuous sampling for radionuclides per 40 CFR 61. None of the Battelle-owned buildings require continuous emission sampling

  19. Estimates of emergency operating capacity in US manufacturing and nonmanufacturing industries

    Energy Technology Data Exchange (ETDEWEB)

    Belzer, D.B. (Pacific Northwest Lab., Richland, WA (USA)); Serot, D.E. (D/E/S Research, Richland, WA (USA)); Kellogg, M.A. (ERCE, Inc., Portland, OR (USA))

    1991-03-01

    Development of integrated mobilization preparedness policies requires planning estimates of available productive capacity during national emergency conditions. Such estimates must be developed in a manner that allows evaluation of current trends in capacity and the consideration of uncertainties in various data inputs and in engineering assumptions. This study, conducted by Pacific Northwest Laboratory (PNL), developed estimates of emergency operating capacity (EOC) for 446 manufacturing industries at the 4-digit Standard Industrial Classification (SIC) level of aggregation and for 24 key non-manufacturing sectors. This volume presents tabular and graphical results of the historical analysis and projections for each SIC industry. (JF)

  20. Modified totally tubeless percutaneous nephrolithotomy: Is it an effective and safe treatment option for renal and upper ureteral stones?

    Directory of Open Access Journals (Sweden)

    Ho Seok Chung

    2016-12-01

    Full Text Available Introduction: We hypothesized that modified totally tubeless percutaneous nephrolithotomy (PNL without indwelling ureteral stent would minimize postoperative discomfort without complications. Aim : To evaluate the safety, efficacy, and morbidity of standard, tubeless, and modified totally tubeless PNL as well as the usefulness of modified totally tubeless PNL. Material and methods: From November 2011 to February 2015, 211 patients who underwent PNL consecutively were enrolled in this study and divided into 3 groups (group 1: standard, group 2: tubeless, group 3: modified totally tubeless PNL. Patient and stone characteristics, operation time, hemoglobin change, length of hospitalization, stone-free rate, analgesic requirement, and perioperative complications were analyzed and compared among the 3 groups. Results: There were no significant differences in preoperative patient characteristics among the three groups. In the postoperative analysis, the three groups had similar operation time, stone-free rate, perioperative fever and transfusion rate, but group 2 showed superior results in terms of length of hospitalization (p = 0.001. Group 2 and group 3 had a lower analgesic requirement (p = 0.010. Immediate postoperative hemoglobin change (p = 0.001 and tube site complications (p = 0.001 were more common in group 1. Conclusions : Modified totally tubeless PNL was not inferior in terms of postoperative outcomes and safety compared with the standard and tubeless PNL, and avoided the postoperative stent-related symptoms and cystoscopy for double-J stent removal. Modified totally tubeless PNL could be an alternative treatment of choice for management of renal or upper ureteral stones in selected patients.

  1. Waste Tank Vapor Project: Vapor characterization of Tank 241-C-103: Report for SUMMA trademark canister samples received 11/29/93 (sample jobs 4 and 5)

    International Nuclear Information System (INIS)

    Clauss, T.R.; Lucke, R.B.; McVeety, B.; Allwine, K.J.; Fruchter, J.S.

    1994-09-01

    The purpose of Sample Jobs 4 and 5 was to determine whether the organic nitrites observed on the outside of tank 241-C-103 originated in the tank or from degradation products of the high-efficiency particulate air (HEPA) filter. The plan was to take samples from either side of the HE-PA filter. The relative level of organic nitrites would help determine whether they were produced in the filter or the tank. Pacific Northwest Laboratory was responsible for analyzing the SUMMA trademark canisters collected in support of this study. The laboratory was to analyze the SUMMA trademark Canister samples according to letters of instruction and report all semivolatile and volatile organic constituents detected in the tank headspace. Pacific Northwest Laboratory was also to submit a letter report to the Program Manager of all qualitative and quantitative analytical data, and estimate concentrations of any aliphatic nitrites identified. This was one of the first sampling activities for this program, and a number of errors were made both in the field and in the laboratory. Because of these errors, the samples and results were of questionable value. Therefore, Westinghouse program management asked that the analysis of the samples for this report not be completed. This report describes the few results that were generated before we were asked to stop work on this activity. In addition to analyzing SUMMA trademark canisters, PNL operates a site portable weather station near tank 241-C-103. Pacific Northwest Laboratory was required to collect atmospheric data starting 11/15/93, but the weather station was already collecting data during the time of both these two sample jobs (11/12/93 and 11/16/93). Therefore, a summary of the atmospheric data is also presented in this report

  2. Seçilmiş böbrek taşı olgularında tamamen tüpsüz perkütan nefrolitotomi

    Directory of Open Access Journals (Sweden)

    Cemil Aydın

    2014-06-01

    Full Text Available Objectives: Percutaneous nephrolithotomy (PNL is the first-line treatment for large and complex renal calculi. The aim of this study is to evaluate the outcomes of totally tubeless PNL operations. Methods: Between October 2009 and August 2013, outcomes of 68 (23.4% patients treated with totally tubeless PNL method at our clinic were analyzed. Stone disintegration was performed with a pneumatic lithotriptor. Operative findings, duration of hospital stay, analgesia requirement and success rates were retrospectively analyzed performed with totally tubeless PNL. Results: Mean age of patients treated with the totally tubeless PNL was 43.4 ± 13.6 (18-69 years and there were 42 (61,7% men and 26 (38,2% women. Mean operation time, excluding the preparation course, was 39.5±14.8 (25-90 minutes and mean fluoroscopy time was 6.04±4.15 (1-12 minutes. None of the patients demonstrated a urinoma, hemorrhage or residual stones in postoperative ultrasonography and plain radiograph. Two patients had undergone ureterorenoscopy for prolonged leakage of urine and treated by retrograde ureteral double-J stent. Blood transfusion was needed only in two patients. The mean hospitalization time was 1.27±0.36 (1-2 days. Conclusion: We think that totally tubeless PNL may be used in properly suitable cases with mil-moderate stone load, intact counterside kidney and without any significant complication and need for second- look.

  3. Engineering Task Plan to Expand the Environmental Operational Envelope of Core Sampling

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    This Engineering Task Plan authorizes the development of an Alternative Generation and Analysis (AGA). The AGA will determine how to expand the environmental operating envelope during core sampling operations

  4. Outcomes of Percutaneous Nephrolithotomy in Patients with Anomalous Kidney

    Directory of Open Access Journals (Sweden)

    Mehmet Yoldaş

    2017-12-01

    Full Text Available Objective: To evaluate the success and complication rate of percutaneous nephrolithotomy (PNL performed in patients with congenital anomalies such as horseshoe kidneys, crossed renal ectopia and renal malrotation. Materials and Methods: Data of 1472 patients who underwent PNL operation in our clinic between January 2007 and January 2015 were analyzed retrospectively. PNL was performed in 28 renal units of 26 patients with congenital renal anomalies. Demographic data of the patients, type of congenital renal anomalies, success rate of PNL and complications were evaluated. Results: Out of 28 PNL-performed renal units, 14 were found out to be with fusion and 14 with rotation anomalies. The average age of the patients was 53 (±1.97 years, 19 were male and 7 were female with an average stone size of 515 (±87.4 mm2. The average operating time was 109 (±11.0 minutes and fluoroscopy time was 191 (±48.4 seconds. The stone-free rate detected postoperatively by computed tomography was 55%. Complications included postoperative fever in 3 patients, postoperative arteriovenous fistula in 1 patient, and intraoperative colon injury in 1 patient. Conclusion: PNL is a safe and effective method in the treatment of stones in kidneys with congenital anomalies.

  5. Design and performance of a full-scale spray calciner for nonradioactive high-level-waste-vitrification studies

    International Nuclear Information System (INIS)

    Miller, F.A.

    1981-06-01

    In the spray calcination process, liquid waste is spray-dried in a heated-wall spray dryer (termed a spray calciner), and then it may be combined in solid form with a glass-forming frit. This mixture is then melted in a continuous ceramic melter or in an in-can melter. Several sizes of spray calciners have been tested at PNL- laboratory scale, pilot scale and full scale. Summarized here is the experience gained during the operation of PNL's full-scale spray calciner, which has solidified approx. 38,000 L of simulated acid wastes and approx. 352,000 L of simulated neutralized wastes in 1830 h of processing time. Operating principles, operating experience, design aspects, and system descriptions of a full-scale spray calciner are discussed. Individual test run summaries are given in Appendix A. Appendices B and C are studies made by Bechtel Inc., under contract by PNL. These studies concern, respectively, feed systems for the spray calciner process and a spray calciner vibration analysis. Appendix D is a detailed structural analysis made at PNL of the spray calciner. These appendices are included in the report to provide a complete description of the spray calciner and to include all major studies made concerning PNL's full-scale spray calciner

  6. Effects of XPS operational parameters on investigated sample surfaces

    International Nuclear Information System (INIS)

    Mrad, O.; Ismail, I.

    2013-04-01

    In this work, we studied the effects of the operating conditions of the xray photoelectron spectroscopy analysis technique (XPS) on the investigated samples. Firstly, the performances of the whole system have been verified as well as the accuracy of the analysis. Afterwards, the problem of the analysis of insulating samples caused by the charge buildup on the surface has been studied. The use of low-energy electron beam (<100 eV) to compensate the surface charge has been applied. The effect of X-ray on the samples have been assessed and was found to be nondestructive within the analysis time. The effect of low- and high-energy electron beams on the sample surface have been investigated. Highenergy electrons were found to have destructive effect on organic samples. The sample heating procedure has been tested and its effect on the chemical stat of the surface was followed. Finally, the ion source was used to determine the elements distribution and the chemical stat of different depths of the sample. A method has been proposed to determine these depths (author).

  7. Totally tubeless percutaneous nephrolithotomy is feasible in morbidly obese patients.

    Science.gov (United States)

    Aghamir, Seyed Mohammad Kazem; Mohseni, Mohammad Ghasem; Hosseini, Seyed Reza; Salavati, Alborz; Ganjali, Hossein; Fallah, Mohammad Ali; Rezaei, Hamed; Modaresi, Seyed Saeed

    2017-06-01

    Regarding technical difficulties that obese body habitus might impose to percutaneous nephrolithotomy (PNL) success and higher risk of peri-operative complications in this group of patients, we decided to retrospectively gather data from our patients during past 8 years to determine the stone free and complication rates. Between January 2007-December 2015, seventy-eight obese patients with body mass index over 35 who had indication for PNL including stones larger than 2 cm in pelvi-calyceal system or smaller extracorporeal shock wave lithotripsy (ESWL) resistant stones or who were not a fit candidate for ESWL due to increased skin to target distance, with no contraindication of PNL (including bleeding diathesis, inability to be positioned in prone) were enrolled. They were randomly assigned to group 1 (standard PNL with nephrostomy and ureteral stent) or group 2 (totally tubeless PNL with no ureteral stent and no nephrostomy). The outcomes were compared. The transfusion rate, operation time, and the hemoglobin drop were same across the groups (p>0.05). Total analgesic use was equivalent of 33.8 vs. 14.7 mgs of morphine sulfate (18-77 mg) and was significantly lower in total tubeless group (p=0.001). Return to normal activity was described as total number of in-patient and outpatient days from time of admission to the point which the patients returns to normal life activity such as going to job or school and was 19.4 vs. 9.3 days (6-30 days, p=0.001). Totally tubeless PNL in obese subjects would have lower analgesic use and return to normal activity versus standard PNL. Totally tubeless PNL is recommended for obese patients.

  8. Operational air sampling report, July 1--December 31, 1992

    International Nuclear Information System (INIS)

    Lyons, C.L.

    1993-04-01

    Nevada Test Site postshot and tunnel events generate beta/gamma fission products. The REECo air sampling program is designed for measurement of these radionuclides at various facilities supporting these events. Monthly radon sampling is done for documentation of working levels in the tunnel complexes, which would be expected to have the highest radon levels for on-site facilities. Out of a total of 628 air samples taken in the tunnel complexes, 24 showed airborne fission products with concentrations well below their respective Derived Air Concentrations (DAC). All of these were related to event reentry or mineback operations. Tritiated water vapor concentrations were very similar to previously reported levels. The 838 air samples taken at the Area-6 decontamination bays and laundry were again well below any DAC calculation standard and negative for any airborne fission products from laboratory analyses

  9. Operable Unit 3-13, Group 3, Other Surface Soils (Phase II) Field Sampling Plan

    Energy Technology Data Exchange (ETDEWEB)

    G. L. Schwendiman

    2006-07-27

    This Field Sampling Plan describes the Operable Unit 3-13, Group 3, Other Surface Soils, Phase II remediation field sampling activities to be performed at the Idaho Nuclear Technology and Engineering Center located within the Idaho National Laboratory Site. Sampling activities described in this plan support characterization sampling of new sites, real-time soil spectroscopy during excavation, and confirmation sampling that verifies that the remedial action objectives and remediation goals presented in the Final Record of Decision for Idaho Nuclear Technology and Engineering Center, Operable Unit 3-13 have been met.

  10. Intrarenal Surgery vs Percutaneous Nephrolithotomy in the Management of Lower Pole Stones Greater than 2 cm.

    Science.gov (United States)

    Koyuncu, Hakan; Yencilek, Faruk; Kalkan, Mehmet; Bastug, Yavuz; Yencilek, Esin; Ozdemir, Ahmet Tunc

    2015-01-01

    To compare the efficacy of RIRS and PNL in lower pole stones ≥ 2 cm. Materials and and Methods: A total of 109 patients who underwent PNL or RIRS for solitary lower pole stone between April 2009 and December 2012, were retrospectively analyzed. Lower pole stone was diagnosed with CT scan. Stone size was assessed as the longest axis of the stone. All patients were informed about the advantages, disadvantages and probable complications of both PNL and RIRS before the selection of the procedure. Patients decided the surgery type by themselves without being under any influences and written informed consent was obtained from all patients prior to the surgery. Patients were divided into two groups according to the patients' preference of surgery type. Group 1 consisted of 77 patients who underwent PNL and Group 2 consisted of 32 patients treated with RIRS. Stone free statuses, postoperative complications, operative time and hospitalization time were compared in both groups. There was no statistical significance between the two groups in mean age, stone size, stone laterality, mean follow-up periods and mean operative times. In PNL group, stone-free rate was 96.1% at first session and 100% after the additional procedure. In Group 2, stone-free rate was 90.6% at the first procedure and 100% after the additional procedure. The final stone-free rates and operative times were similar in both groups. RIRS should be an effective treatment alternative to PNL in lower pole stones larger than 2 cm, especially in selected patients.

  11. Intrarenal Surgery vs Percutaneous Nephrolithotomy in the Management of Lower Pole Stones Greater than 2 cm

    Directory of Open Access Journals (Sweden)

    Hakan Koyuncu

    2015-04-01

    Full Text Available Purpose To compare the efficacy of RIRS and PNL in lower pole stones ≥2 cm. Materials and and Methods: A total of 109 patients who underwent PNL or RIRS for solitary lower pole stone between April 2009 and December 2012, were retrospectively analyzed. Lower pole stone was diagnosed with CT scan. Stone size was assessed as the longest axis of the stone. All patients were informed about the advantages, disadvantages and probable complications of both PNL and RIRS before the selection of the procedure. Patients decided the surgery type by themselves without being under any influences and written informed consent was obtained from all patients prior to the surgery. Patients were divided into two groups according to the patients’ preference of surgery type. Group 1 consisted of 77 patients who underwent PNL and Group 2 consisted of 32 patients treated with RIRS. Stone free statuses, postoperative complications, operative time and hospitalization time were compared in both groups. Results There was no statistical significance between the two groups in mean age, stone size, stone laterality, mean follow-up periods and mean operative times. In PNL group, stone-free rate was 96.1% at first session and 100% after the additional procedure. In Group 2, stone-free rate was 90.6% at the first procedure and 100% after the additional procedure. The final stone-free rates and operative times were similar in both groups. Conclusions RIRS should be an effective treatment alternative to PNL in lower pole stones larger than 2 cm, especially in selected patients.

  12. Factors Influencing Complications of Percutaneous Nephrolithotomy: A Single-Center Study.

    Science.gov (United States)

    Oner, Sedat; Okumus, Muhammed Masuk; Demirbas, Murat; Onen, Efe; Aydos, Mustafa Murat; Ustun, Mehmet Hakan; Kilic, Metin; Avci, Sinan

    2015-11-14

    Percutaneous nephrolithotomy (PNL) is a minimally invasive procedure used for successful treatment of renal calculi. However, it is associated with various complications. We assessed the complications and their potential influencing factors in patients who had undergone PNL. In total, 1750 patients who had undergone PNL from November 2003 to June 2011 were evaluated retrospectively. PNL complications and possible contributing risk factors (age, sex, serum creatinine level, previous operations, hydronephrosis, calculi size, localization, opacity, surgeon's experience, accessed calyxes, number of accesses, and costal entries) were determined. Receiver operating characteristic (ROC) analysis was used to investigate the cutoff values of the data. Ideal cutoff value was determined by Youden's J statistic. All the demographic and clinical variables were examined using backward stepwise logistical regression analysis. Continuous variables were categorized with logistic regression analysis according to the cutoff values. Complications occurred in 396 (24.4%) patients who had undergone PNL. Hemorrhage requiring blood transfusion occurred in 221 (12.6%) patients, hemorrhage requiring arterial embolization occurred in 7 (0.4%) patients, perirenal hematoma occurred in 17 (0.97%) patients, hemo-pneumothorax occurred in 32 (1.8%) patients, and colon perforation occurred in 4 (0.22%) patients. Three patients (0.06%) died of severe urosepsis, and one patient (0.02%) died of severe bleeding. The calculus size, localization, access site, number of accesses, presence of staghorn stones, surgeon's experience, and duration of the operation significantly affected the complication risk. Our retrospective evaluation of this large patient series reveals that, PNL is a very effective treatment modality for kidney stones. However, although rare, serious complications including death can occur.

  13. Tank 241-A-104 tank characterization plan

    International Nuclear Information System (INIS)

    Schreiber, R.D.

    1994-01-01

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, WHC 222-S Laboratory, and PNL 325 Analytical Chemistry Laboratory. The scope of this plan is to provide guidance for the sampling and analysis of auger samples from tank 241-A-104. This Tank Characterization Plan will identify characterization objectives pertaining to sample collection, hot cell sample isolation, and laboratory analytical evaluation and reporting requirements in addition to reporting the current contents and status of the tank as projected from historical information

  14. The Observation of Fault Finiteness and Rapid Velocity Variation in Pnl Waveforms for the Mw 6.5, San Simeon, California Earthquake

    Science.gov (United States)

    Konca, A. O.; Ji, C.; Helmberger, D. V.

    2004-12-01

    We observed the effect of the fault finiteness in the Pnl waveforms from regional distances (4° to 12° ) for the Mw6.5 San Simeon Earthquake on 22 December 2003. We aimed to include more of the high frequencies (2 seconds and longer periods) than the studies that use regional data for focal solutions (5 to 8 seconds and longer periods). We calculated 1-D synthetic seismograms for the Pn_l portion for both a point source, and a finite fault solution. The comparison of the point source and finite fault waveforms with data show that the first several seconds of the point source synthetics have considerably higher amplitude than the data, while finite fault does not have a similar problem. This can be explained by reversely polarized depth phases overlapping with the P waves from the later portion of the fault, and causing smaller amplitudes for the beginning portion of the seismogram. This is clearly a finite fault phenomenon; therefore, can not be explained by point source calculations. Moreover, the point source synthetics, which are calculated with a focal solution from a long period regional inversion, are overestimating the amplitude by three to four times relative to the data amplitude, while finite fault waveforms have the similar amplitudes to the data. Hence, a moment estimation based only on the point source solution of the regional data could have been wrong by half of magnitude. We have also calculated the shifts of synthetics relative to data to fit the seismograms. Our results reveal that the paths from Central California to the south are faster than to the paths to the east and north. The P wave arrival to the TUC station in Arizona is 4 seconds earlier than the predicted Southern California model, while most stations to the east are delayed around 1 second. The observed higher uppermost mantle velocities to the south are consistent with some recent tomographic models. Synthetics generated with these models significantly improves the fits and the

  15. Efficacy of surgical techniques and factors affecting residual stone rate in the treatment of kidney stones.

    Science.gov (United States)

    Aydemir, Hüseyin; Budak, Salih; Kumsar, Şükrü; Köse, Osman; Sağlam, Hasan Salih; Adsan, Öztuğ

    2014-09-01

    In this study, we aimed to evaluate, the efficacy of surgical methods and the factors affecting the residual stone rate by scrutinizing retrospectively the patients who had undergone renal stone surgery. Records of 109 cases of kidney stones who had been surgically treated between January 2010, and July 2013 were reviewed. Patients were divided into three groups in terms of surgical treatment; open stone surgery, percutaneous nephrolithotomy (PNL) and retrograde intrarenal surgery (RIRS). Patients' history, physical examination, biochemical and radiological images and operative and postoperative data were recorded. The patients had undergone PNL (n=74; 67.9%), RIRS (n=22;20.2%), and open renal surgery (n=13; 11.9%). The mean and median ages of the patients were 46±9, 41 (21-75) and, 42 (23-67) years, respectively. The mean stone burden was 2.6±0.7 cm(2) in the PNL, 1.4±0.1 cm(2) in the RIRS, and 3.1±0.9 cm(2) in the open surgery groups. The mean operative times were 126±24 min in the PNL group, 72±12 min in the RIRS group and 82±22 min in the open surgery group. The duration of hospitalisation was 3.1±0.2 days, 1.2±0.3 days and 3.4±1.1 days respectively. While the RIRS group did not need blood transfusion, in the PNL group blood transfusions were given in the PNL (n=18), and open surgery (n=2) groups. Residual stones were detected in the PNL (n=22), open surgery (n=2), and RIRS (n=5) groups. PNL and RIRS have been seen as safe and effective methods in our self application too. However, it should not be forgotten that as a basical method, open surgery may be needed in cases of necessity.

  16. Percutaneous Nephrolithotomy in Autosomal Dominant Polycystic Kidney Disease: Is it Different from Percutaneous Nephrolithotomy in Normal Kidney?

    Science.gov (United States)

    Singh, Vishwajeet; Sinha, Rahul Janak; Gupta, Dheeraj Kumar

    2013-08-01

    Nephrolithiasis has been reported in 20-28% of patients, of whom 50% are symptomatic for stone disease and 20% require definite urologic intervention. The management of nephrolithiasis includes oral alkali dissolution therapy, extracorporeal shock wave lithotripsy and surgical treatment. In such patients, percutaneous nephrolithotomy (PNL) as a method of stone treatment has been reported in few cases with limited experience. The aim of this study is to present our experience of PNL in autosomal dominant polycystic kidney disease (ADPKD) and assessing the outcome results. From 2002 to 2011, 22 patients (26 renal units) suffering from ADPKD with stone were managed by PNL. Demographic characteristics, operative parameters and postoperative complications were recorded and analysed. The overall success rate of PNL was 82.1% and PNL with extracorporeal shock wave lithotripsy for clinically significant residual fragments was 92.85% respectively. The hematuria required blood transfusion (n = 9), postoperative fever due to cyst infection (n = 4) and paralytic ileus (n = 3) were recorded. The PNL in ADPKD PNL is safe and effective but have more postoperative complications such as bleeding requiring transfusions, fever due to cyst infection and paralytic ileus.

  17. Totally tubeless percutaneous nephrolithotomy: is it safe and effective in preschool children?

    Science.gov (United States)

    Ozturk, Ahmet; Guven, Selcuk; Kilinc, Mehmet; Topbaş, Emrah; Piskin, Mesut; Arslan, Mehmet

    2010-12-01

    After the introduction of tubeless percutaneous nephrolithotomy (PNL), many studies conducted in adult patients have confirmed its efficacy and safety. There are limited studies reporting that tubeless PNL can be safely applied in children, however. Furthermore, there are no reports that evaluate the use of totally tubeless PNL in children. The present study evaluates the results of totally tubeless PNL in preschool children. The data of children seen in our clinic who were considered suitable for totally tubeless PNL were analyzed. Of 16 children, 8 patients underwent totally tubeless PNL (group 1) and 8 standard PNL (group 2). The two groups of patients were compared with regard to length of hospitalization, analgesic requirements, transfusion rates, hemoglobin (Hb) decrease, and immediate, early, and late complications. The mean ages of the patients were 56.6 months (9-84 mos) and 56.0 months (5-84 mos), and the mean follow-up was 21.5 months (3-44 mos) and 43.4 months (36-54 mos) in groups 1 and 2, respectively. Both groups were similar with regard to age, stone size, Hb change, and complications. Although operation duration, hospitalization period, and analgesic requirement were less in the totally tubeless PNL group, these differences were not statistically significant. The latest application of PNL, totally tubeless PNL, is also a safe and effective procedure in very small children if they are selected properly and if the surgeon has sufficient experience with the procedure. More studies with a higher number of participants are needed, however, to confirm that totally tubeless PNL increases the comfort of pediatric patients, decreases their hospitalization period, and is more economical.

  18. Review and evaluation of Transamerica Delaval, Inc., diesel engine reliability and operability: Grand Gulf Nuclear Station Unit 1

    International Nuclear Information System (INIS)

    1984-07-01

    PNL and its consultants conclude that the TDI diesel engines at the GGNS have the needed operability and reliability to fulfill their intended (auxiliary) emergency power function for the first refueling cycle. This conclusion is reached with a number of understandings regarding limits to the engine requirements, NRC concurrence with MP and L findings/conclusions regarding items to be supplied to NRC, limitations on the engine Brake Mean Effective Pressure (BMEP), and MP and L's implementation of the modifications to their proposed surveillance and maintenance program

  19. Percutaneous Nephrolithotomy: Our Results of a Single-Centre Analysis in 2300 Cases

    Directory of Open Access Journals (Sweden)

    Akif Erbin

    2014-03-01

    Full Text Available Aim: In this study, we evaluated the results of 2300 patients who underwent percutaneous nephrolithotomy (PNL between March 2002 and April 2013. Methods: In our clinic, a total of 2300 PNL operations were performed between March 2002 - April 2013. Demographic characteristics (age, gender, body mass index, stone features (side, size, location, clinical characteristics of the urinary tract (renal anomaly, previous surgery, previous extracorporeal shock wave lithotripsy, operation parameters (duration of the intervention and fluoroscopy, number of access, location of access, transfusion, complications, post-operative data (length of hospital stay, transfusion, complications, stone-free were recorded on PNL forms. The data were analyzed retrospectively. Results: Of all the PNL operations, 1225 (53.2% were left-sided, 1074 (46.6% were right-sided and 1 was bilateral. The mean age of the subjects was 43.5 (7-83 years and the mean body mass index was 26.6 kg/m2 (12-51. A total of 46 (2% cases had renal anomalies. There were 16 patients with horseshoe kidney. More than one accesses was performed in 18.6% of the patient and intercostal access was done in 9.8%. Perioperative and post-operative transfusion rates were 1.4% and 2.9%, respectively. The mean stone size was 7.5±4.1 cm2. Stone-free (SF rate was 65.1% and success rate was 78.5%. Conclusion: With increasing experience and advances in endourology, PNL is being widely performed with low morbidity and high success in our country as in the world. (The Me­di­cal Bul­le­tin of Ha­se­ki 2013; 51: 19-24

  20. Technical assistance to Department of Energy/Office of Operational Safety Assurance Program for remedial action

    International Nuclear Information System (INIS)

    Denham, D.H.; Cross, F.T.; Kennedy, W.E. Jr.; Marks, S.; Soldat, J.K.; Stenner, R.D.

    1986-01-01

    This project was initiated in FY 1984 to provide technical assistance to the Department of Energy (DOE), Office of Operational Safety (OOS) in developing and implementing its Assurance Program for Remedial Action (APRA), i.e., overview of the DOE remedial action programs. During this second year of the project,* the technical assistance included report and procedure reviews, and assistance with conducting the Uranium Mill Tailings Remedial Action Program (UMTRAP) Office (DOE/AL) appraisal. This included participation in preappraisal visits to UMTRAP sites in Canonsburg, Pennsylvania; Grand Junction, Colorado; and Salt Lake City, Utah. Pacific Northwest Laboratory (PNL) also transferred the PNL-developed document review software to the Oak Ridge Associated Universities (ORAU) staff in Grand Junction, Colorado, in anticipation of future document reviews by the ORAU staff. Other accomplishments have included publication of two formal documents and three project reports, preparation and presentation of five topical reports at national and international meetings, two foreign trip reports, and comments on proposed draft standards of the Environmental Protection Agency (40 CFR 193). The project manager has also participated on National Council on Radiation Protection and Measurements (NCRP) and American Society for Testing and Materials (ASTM) subcommittees developing decommissioning standards, as well as International Atomic Energy Agency (IAEA) advisory groups developing environmental monitoring guidelines

  1. Aging of nuclear station diesel generators: Evaluation of operating and expert experience: Workshop

    International Nuclear Information System (INIS)

    Hoopingarner, K.R.; Vause, J.W.

    1987-08-01

    Pacific Northwest Laboratory (PNL) evaluated operational and expert experience pertaining to the aging degradation of diesel generators in nuclear service. The research, sponsored by the US Nuclear Regulatory Commission (NRC), identified and characterized the contribution of aging to emergency diesel generator failures. This report, Volume II, reports the results of an industry-wide workshop held on May 28 and 29, 1986, to discuss the technical issues associated with aging of nuclear service emergency diesel generators. The technical issues discussed most extensively were: man/machine interfaces, component interfaces, thermal gradients of startup and cooldown and the need for an accurate industry database for trend analysis of the diesel generator system

  2. Does previous open renal surgery or percutaneous nephrolithotomy affect the outcomes and complications of percutaneous nephrolithotomy.

    Science.gov (United States)

    Ozgor, Faruk; Kucuktopcu, Onur; Sarılar, Omer; Toptas, Mehmet; Simsek, Abdulmuttalip; Gurbuz, Zafer Gokhan; Akbulut, Mehmet Fatih; Muslumanoglu, Ahmet Yaser; Binbay, Murat

    2015-11-01

    In this study, we aim to evaluate the effectiveness and safety of PNL in patients with a history of open renal surgery or PNL by comparing with primary patients and to compare impact of previous open renal surgery and PNL on the success and complications of subsequent PNL. Charts of patients, who underwent PNL at our institute, were analyzed retrospectively. Patients were divided into three groups according to history of renal stone surgery. Patients without history of renal surgery were enrolled into Group 1. Other patients with previous PNL and previous open surgery were categorized as Group 2 and Group 3. Preoperative characteristic, perioperative data, stone-free status, and complication rates were compared between the groups. Stone-free status was accepted as completing clearance of stone and residual fragment smaller than 4 mm. Eventually, 2070 patients were enrolled into the study. Open renal surgery and PNL had been done in 410 (Group 2) and 131 (Group 3) patients, retrospectively. The mean operation time was longer (71.3 ± 33.5 min) in Group 2 and the mean fluoroscopy time was longer (8.6 ± 5.0) in Group 3 but there was no statistically significant difference between the groups. Highest stone clearance was achieved in primary PNL patients (81.62%) compared to the other groups (77.10% in Group 2 and 75.61% in Group 3). Stone-free rate was not significantly different between Group 2 and Group 3. Fever, pulmonary complications, and blood transfusion requirement were not statically different between groups but angioembolization was significantly higher in Group 2. Percutaneous nephrolithotomy is a safe and effective treatment modality for patients with renal stones regardless history of previous PNL or open renal surgery. However, history of open renal surgery but not PNL significantly reduced PNL success.

  3. Crossing the Undecidability Border with Extensions of Propositional Neighborhood Logic over Natural Numbers

    DEFF Research Database (Denmark)

    Monica, Dario Della; Goranko, Valentin; Montanari, Angelo

    2012-01-01

    of PNL extended with modal operators corresponding to Allen's relations begins, begun by, and before/. This paper aims at demonstrating that PNL and its metric version MPNL, interpreted over natural numbers, are indeed very close to the border with undecidability, and even relatively weak extensions...... of them become undecidable. In particular, we show that (i) the addition of binders on integer variables ranging over interval lengths makes the resulting hybrid extension of MPNL undecidable, and (ii) a very weak first-order extension of the future fragment of PNL, obtained by replacing proposition...

  4. Operational air sampling report

    International Nuclear Information System (INIS)

    Lyons, C.L.

    1994-03-01

    Nevada Test Site vertical shaft and tunnel events generate beta/gamma fission products. The REECo air sampling program is designed to measure these radionuclides at various facilities supporting these events. The current testing moratorium and closure of the Decontamination Facility has decreased the scope of the program significantly. Of the 118 air samples collected in the only active tunnel complex, only one showed any airborne fission products. Tritiated water vapor concentrations were very similar to previously reported levels. The 206 air samples collected at the Area-6 decontamination bays and laundry were again well below any Derived Air Concentration calculation standard. Laboratory analyses of these samples were negative for any airborne fission products

  5. Demonstration of an approach to waste form qualification through simulation of liquid-fed ceramic melter process operations

    International Nuclear Information System (INIS)

    Reimus, P.W.; Kuhn, W.L.; Peters, R.D.; Pulsipher, B.A.

    1986-07-01

    During fiscal year 1982, the US Department of Energy (DOE) assigned responsibility for managing civilian nuclear waste treatment programs in the United States to the Nuclear Waste Treatment Program (NWTP) at the Pacific Northwest Laboratory (PNL). One of the principal objectives of this program is to establish relationships between vitrification process control and glass quality. Users of the liquid-fed ceramic melter (LFCM) process will need such relationships in order to establish acceptance of vitrified high-level nuclear waste at a licensed federal repository without resorting to destructive examination of the canisters. The objective is to be able to supply a regulatory agency with an estimate of the composition, durability, and integrity of the glass in each waste glass canister produced from an LFCM process simply by examining the process data collected during the operation of the LFCM. The work described here will continue through FY-1987 and culminate in a final report on the ability to control and monitor an LFCM process through sampling and process control charting of the LFCM feed system

  6. Review and evaluation of TDI diesel generator owner's group program plan

    International Nuclear Information System (INIS)

    1984-06-01

    This report documents a review, performed by the Pacific Northwest Laboratory (PNL), of the Transamerica Delaval, Inc. (TDI) Diesel Generator Owner's Group Program Plan. This report was prepared as part of the technical support PNL is providing to the US Nuclear Regulatory Commission (NRC), Division of Licensing, on matters pertaining to the reliability of TDI diesel generators as emergency power sources for safety-related nuclear systems. The report presents the comments and conclusions reached by PNL, with the advice and counsel of five diesel engine consultants, on the principal elements of the Owners' Group Plan: Generic Problem Resolution, Design Review/Quality Revalidation, and Engine Testing and Inspection. Also included are PNL's comments on the related issues of Surveillance and Maintenance, and Administrative Controls. The conclusions drawn from PNL's evaluation of these issues form the basis for two additional topics addressed in the report: Critical Elements Required to Establish Diesel Engine Operability and Reliability, and Considerations for Interim Licensing

  7. Operability test procedure for the Rotary Mode Core Sampling System Exhausters 3 and 4

    International Nuclear Information System (INIS)

    WSaldo, E.J.

    1995-01-01

    This document provides a procedure for performing operability testing of the Rotary Mode Core Sampling System Exhausters 3 ampersand 4. Upon completion of testing activities an operability testing report will be issued

  8. Operability test report for rotary mode core sampling system number 3

    International Nuclear Information System (INIS)

    Corbett, J.E.

    1996-01-01

    This report documents the successful completion of operability testing for the Rotary Mode Core Sampling (RMCS) system number-sign 3. The Report includes the test procedure (WHC-SD-WM-OTP-174), exception resolutions, data sheets, and a test report summary

  9. Data validation report for the 100-HR-3 Operable Unit, fifth round groundwater samples

    International Nuclear Information System (INIS)

    Vukelich, S.E.

    1994-01-01

    The data from the chemical analysis of 68 samples from the 100-HR-3 Operable Unit Third Quarter 1993 Groundwater Sampling Investigation and their related quality assurance samples were reviewed and validated to verify that reported sample results were of sufficient quality to support decisions regarding remedial actions performed at the site. Sample analysis included inorganics and general chemical parameters. Fifty three samples were validated for radiochemical parameters

  10. Data validation report for the 100-D Ponds Operable Unit: 100-D ponds sampling

    International Nuclear Information System (INIS)

    Stankovich, M.T.

    1994-01-01

    Westinghouse-Hanford has requested that 100 percent of the Sample Delivery Groups be validated for the 100-D Ponds Operable Unit Sampling Investigation. Therefore the data from the chemical analysis of all 30 samples from this sampling event and their related quality assurance samples were reviewed and validated to verify that reported sample results were of sufficient quality to support decisions regarding remedial actions performed at this site

  11. Pacific Northwest Laboratory plan to maintain radiation exposure as low as reasonably achievable (ALARA)

    International Nuclear Information System (INIS)

    Higby, D.P.; Denovan, J.T.

    1982-12-01

    This document describes the radiation safety program at the Pacific Northwest Laboratory (PNL). The practices and administrative policies of this program support the principles of ALARA (to maintain radiation exposure as low as reasonably achievable). This document also describes a program to establish safety goals at PNL to help ensure that operations are conducted according to ALARA principles

  12. Percutaneous nephrolithotomy in children: A preliminary report.

    Science.gov (United States)

    Elderwy, Ahmad A; Gadelmoula, Mohamed; Elgammal, Mohamed A; Osama, Ehab; Al-Hazmi, Hamdan; Hammouda, H; Osman, Esam; Abdullah, Medhat A; Neel, Khalid Fouda

    2014-07-01

    The recurrence of pediatric nephrolithiasis, the morbidity of repeated open surgical treatment as well as our experience in percutaneous nephrolithotomy (PNL) in adult patients, all derived us to shift to PNL for managing renal stones >1.5 cm in pediatric patients. Our aim of this study is to evaluate the safety and efficacy of PNL in pediatric patients. During the period of the month between May 2011 and April 2013, 38 children (47 renal units) underwent PNL for renal stones 1.5-5 cm in length. Patient demographics, stone characteristics, and clinical outcome were prospectively studied. Data of those who underwent conventional and tubeless PNL were compared. Median follow-up period was 12 months (range: 6-24). The median age at presentation was 8-year (range: 3-12). The operative time ranged from 30 to 120 min (median 90). Overall stone clearance rate was 91.5% after single PNL. The median hospital stay was 3 days. Auxiliary procedures were successful for the remaining 4 patients (nephroscopic clearance in one and shockwave lithotripsy in 3). Tubeless PNL was performed in 17 renal units with a comparable outcome to conventional ones. The perioperative complications were noted in 5/47 (10.6%) of all procedures (Clavien Grade II in 4 and Clavien Grade IIIa in 1) and were managed conservatively. Percutaneous nephrolithotomy for renal stones in pediatric patients is safe and feasible if performed by a well-experienced endourologist. Tubeless PNL is a better choice for children.

  13. Comparison of retrograde intrarenal surgery and mini-percutaneous nephrolithotomy in management of lower-pole renal stones with a diameter of smaller than 15 mm.

    Science.gov (United States)

    Kirac, Mustafa; Bozkurt, Ömer Faruk; Tunc, Lutfi; Guneri, Cagri; Unsal, Ali; Biri, Hasan

    2013-06-01

    The aim of this study was to compare the outcomes of retrograde intrarenal surgery (RIRS) and miniaturized percutaneous nephrolithotomy (mini-PNL) in management of lower-pole renal stones with a diameter smaller than 15 mm. Between December 2009 and July 2012, the patients with the diagnosis of lower-pole stones were evaluated by ultrasonography, intravenous pyelography and computed tomography. The records of 73 evaluable patients who underwent mini-PNL (n = 37) or RIRS (n = 36) for lower-pole (LP) stones with diameter smaller than 15 mm were reviewed retrospectively. Of the 73 patients, 37 underwent mini-PNL and 36 underwent RIRS. The stone-free rates were 89.1 and 88.8 % for mini-PNL and RIRS groups, respectively. The mean operation time was 53.7 ± 14.5 in the mini-PNL group but 66.4 ± 15.8 in the RIRS group (P = 0.01). The mean fluoroscopy times and hospitalization times were significantly higher in the mini-PNL group. There was no major complication in any patient. RIRS and mini-PNL are safe and effective methods for treatment of LP calculi with a diameter smaller than 15 mm. RIRS is a non-invasive and feasible treatment option, and has also short hospitalization time, low morbidity and complication rate. It may be an alternative of mini-PNL in the treatment LP calculi with smaller than 15 mm.

  14. SymPix: A Spherical Grid for Efficient Sampling of Rotationally Invariant Operators

    Science.gov (United States)

    Seljebotn, D. S.; Eriksen, H. K.

    2016-02-01

    We present SymPix, a special-purpose spherical grid optimized for efficiently sampling rotationally invariant linear operators. This grid is conceptually similar to the Gauss-Legendre (GL) grid, aligning sample points with iso-latitude rings located on Legendre polynomial zeros. Unlike the GL grid, however, the number of grid points per ring varies as a function of latitude, avoiding expensive oversampling near the poles and ensuring nearly equal sky area per grid point. The ratio between the number of grid points in two neighboring rings is required to be a low-order rational number (3, 2, 1, 4/3, 5/4, or 6/5) to maintain a high degree of symmetries. Our main motivation for this grid is to solve linear systems using multi-grid methods, and to construct efficient preconditioners through pixel-space sampling of the linear operator in question. As a benchmark and representative example, we compute a preconditioner for a linear system that involves the operator \\widehat{{\\boldsymbol{D}}}+{\\widehat{{\\boldsymbol{B}}}}T{{\\boldsymbol{N}}}-1\\widehat{{\\boldsymbol{B}}}, where \\widehat{{\\boldsymbol{B}}} and \\widehat{{\\boldsymbol{D}}} may be described as both local and rotationally invariant operators, and {\\boldsymbol{N}} is diagonal in the pixel domain. For a bandwidth limit of {{\\ell }}{max} = 3000, we find that our new SymPix implementation yields average speed-ups of 360 and 23 for {\\widehat{{\\boldsymbol{B}}}}T{{\\boldsymbol{N}}}-1\\widehat{{\\boldsymbol{B}}} and \\widehat{{\\boldsymbol{D}}}, respectively, compared with the previous state-of-the-art implementation.

  15. Percutaneous Nephrolithotomy in Patients With BMI >50: Single Surgeon Outcomes and Feasibility.

    Science.gov (United States)

    Streeper, Necole M; Radtke, Andrew C; Penniston, Kristina L; McDermott, John C; Nakada, Stephen Y

    2016-01-01

    To evaluate the use of percutaneous nephrolithotomy (PNL) and technical approach in the super obese population (body mass index [BMI] ≥ 50). We performed a retrospective review of 31 consecutive PNL cases with a BMI > 50 from a single surgeon (SYN) from 1995 to 2013. Procedures were performed in the prone position, and upper pole access was used. Operative time, length of hospital stay, stone burden, complication rates, and stone-free rates were measured. Of the 31 patients who underwent PNL (age 51.2 ± 12; 71% female), the mean BMI was 59.1 ± 6 kg/m(2) (range 50.4-71.7 kg/m(2)). Mean stone burden was 3.8 cm ± 2. The majority of patients (90.3%) had an upper pole puncture site for access with an operative time of 122.1 ± 75 minutes. The technique was similar to non-obese patients; however, there was a need for extra-long instrumentation. The overall stone-free rate was 71%, with utilization of a second-look PNL in 11 cases. The complication rate, Clavien grade 3 or higher, was 9.7% (3 of 31). PNL is technically feasible, safe, and effective in patients with a BMI ≥ 50. The complication rate, length of hospital stay, and stone-free rate with use of second-look PNL in super obese patients are comparable to severely obese patients. Intervention should not be automatically ruled out or delayed based on the patient's BMI alone. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Flexible Ureterorenoscopy versus Mini-Percutaneous Nephrolithotomy for the Treatment of Renal Stones.

    Science.gov (United States)

    Ergin, Giray; Kirac, Mustafa; Kopru, Burak; Ebiloglu, Turgay; Biri, Hasan

    2018-04-22

    To compare the pain status and stone free rates of flexible ureterorenoscopy (F-URS) versus mini-percutaneousnephrolithotomy (mini-PNL) for the treatment of 1-to 2-cm renal stones. This study was retrospectively designed with match paired method. Between January 2013 and December 2016, 387 patients underwent stone surgery for renal stones, 45 patients underwent FURS and 45 patients underwent mini-PNL. 90 patients were divided into two groups according to the surgical procedures. Group 1 patients underwent F-URS, and Group 2 patients underwent mini-PNL. During the intraoperative andpostoperative periods, pain management for all patients was standardized. Pain scores were determined using a visual analogue scale (VAS) completed at 2, 6, 12 and 24 hours postoperatively. The stone free status, hemoglobin levels, fluoroscopy time (FT), operation time (OT), hospitalization time (HT), return to work time (RWT), and complications were noted for each patient. Of all patients, the mean age was 41.1 ± 12.1 years and the mean stone size was 13.9 ± 2.9 mm. The VAS scores were significantly higher in the mini-PNL group at 2, 6, 12 and 24 hours (P .05); however, the hemoglobin decreases and the fluoroscopy, operation, hospitalization and return to work times were higher in the mini-PNL group than in the F-URS group (P work duration. We think that F-URS is more comfortable and less painful than mini-PNL and achieves a similar stone free rate for the treatment of 1- to 2-cm renal stones.

  17. Nuclear isotope measurement in the Hanford environment

    International Nuclear Information System (INIS)

    Wacker, J.F.; Stoffel, J.J.; Kelley, J.M.

    1995-01-01

    The Pacific Northwest Laboratory (PNL) is located at the federal government's Hanford Site in southeastern Washington State, which was built during World War II as part of the secret Manhattan Project to develop the atomic bomb. Monitoring of the Site itself and surrounding environs for Hanford-related radionuclides has been a routine part of the operations since 1944. One of the most sensitive analytical methods used is thermal ionization mass spectrometry (TIMS) with triple-sector mass spectrometers. Normal geometry instruments have an abundance sensitivity of 10 -9 for uranium while the authors' newest Triple-Sector Isotope Mass Spectrometer (TRISM), utilizing a new ion-optical design developed at PNL, has an abundance sensitivity of 10 -11 . In favorable cases, sensitivity is such that complete isotopic analyses are obtained on total samples in the femtogram range; and minor isotopes in the attogram range are measured

  18. Surgical management of urinary stones with abnormal kidney anatomy

    Directory of Open Access Journals (Sweden)

    Giray Ergin

    2017-04-01

    Full Text Available In spite of the fact that urologic surgical techniques used by urologists are becoming more and more minimally invasive and easier because of developing technologies, surgical approaches for the urinary stones in kidneys with abnormal anatomy are still confusing. The objective of this article is to determine the treatment options in these kidneys. For this purpose, between 2005 and 2015, we retrospectively evaluated patients operated for urolithiasis with various congenital renal anomalies in five referral urology clinics in our country. Of the 178 patients (110 male, 60 female, 96 had horseshoe kidneys, 42 had pelvic ectopic kidneys (PEKs, and 40 had isolated rotation anomalies (IRAs of the kidney. We evaluated the patients for stone-free rate (SFR, mean operation time, mean hospitalization time, and complication rate. In horseshoe kidney, SFRs for retrograde intrarenal surgery (RIRS and percutaneous nephrolithotomy (PNL groups were 72.2% and 90%, respectively. In PEKs, these rates were 83.6% and 100% for RIRS and laparoscopic pyelolithotomy, respectively. SFRs in kidneys with IRA were 75% for RIRS and 83.3% for PNL. The mean operation time for RIRS and PNL groups in horseshoe kidney was 40.5±11.2 minutes and 74.5±19.3 minutes, respectively. In PEKs, these times were 52.1±19.3 minutes and 53.1±24.3 minutes for RIRS and laparoscopic pyelolithotomy, respectively. Mean operation time in kidneys with IRA was 48.7±14.4 minutes for RIRS and 53.2±11.3 minutes for PNL. Mean hospitalization times for RIRS and PNL groups in horseshoe kidneys were 1.4±0.7 days and 2.2±1.4 days, respectively. In PEKs, these times were 2.7±1.8 days and 1.9±0.4 days for RIRS and laparoscopic pyelolithotomy, respectively. Mean operation time in kidneys with IRA was 1.5±0.9 days for RIRS and 1.8±0.6 days for PNL. The results of our study showed that RIRS could be used in all of types of abnormal kidneys with small- and medium-sized renal calculi safely and

  19. Comparison of retrograde intrarenal surgery versus a single-session percutaneous nephrolithotomy for lower-pole stones with a diameter of 15 to 30 mm: A propensity score-matching study.

    Science.gov (United States)

    Jung, Gyoo Hwan; Jung, Jae Hyun; Ahn, Tae Sik; Lee, Joong Sub; Cho, Sung Yong; Jeong, Chang Wook; Lee, Seung Bae; Kim, Hyeon Hoe; Oh, Seung-June

    2015-07-01

    To investigate surgical outcomes between retrograde intrarenal surgery (RIRS) and percutaneous nephrolithotomy (PNL) groups for a main stone sized 15 to 30 mm and located in the lower-pole calyx. Patients who underwent PNL or RIRS for a main stone sized 15 to 30 mm and located in the lower-pole calyx were retrospectively reviewed. Each patient in the RIRS group was matched to one in the PNL group on the basis of calculated propensity scores by use of age, sex, body mass index, previous treatment history, stone site, maximum stone size, and stone volume. We compared perioperative outcomes between the unmatched and matched groups. Patients underwent PNL (n=87, 66.4%) or RIRS (n=44, 33.6%). After matching, 44 patients in each group were included. Mean patient age was 54.4 ± 13.7 years. Perioperative hemoglobin drop was significantly higher and the hospital stay was longer in the PNL group than in the RIRS group. The operative time was significantly longer in the RIRS group than in the PNL group. Stone-free rates were higher and complications rates were lower in the RIRS group than in the PNL group without statistical significance. The presence of a stone located in the lower-anterior minor calyx was a predictor of stone-free status. RIRS and single-session PNL for patients with a main stone of 15 to 30 mm located in the lower-pole calyx showed comparable surgical results. However, RIRS can be performed more safely than PNL with less bleeding. Stones in the lower-anterior minor calyx should be carefully removed during these procedures.

  20. Operational safety

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    The PNL Safety, Standards and Compliance Program contributed to the development and issuance of safety policies, standards, and criteria; for projects in the nuclear and nonnuclear areas. During 1976 the major emphasis was on developing criteria, instruments and methods to assure that radiation exposure to occupational personnel and to people in the environs of nuclear-related facilities is maintained at the lowest level technically and economically practicable. Progress in 1976 is reported on the preparation of guidelines for radiation exposure; Pu dosimetry studies; the preparation of an environmental monitoring handbook; and emergency instrumentation preparedness

  1. Reducción del miedo escénico y mejora del afecto positivo, la autoeficacia y el desempeño ante la actuación en público: un cuasi=experimento aplicando PNL

    OpenAIRE

    Serrano Leiva, Damaris

    2015-01-01

    Treball final de Grau en Psicologia. Codi: PS1048. Curs acadèmic 2014-2015 En este estudio, se llevó a cabo un cuasi-experimento con el fin de evaluar la eficacia de dos técnicas en Programación Neuro Linguística (PNL): anclas y submodalidades en la mejora del afecto positivo, autoeficacia y desempeño, y la reducción del miedo escénico y del afecto negativo en alumnos de teatro de la Escuela Municipal de Villarreal. Para ello, se establecieron dos condiciones: Un grupo experime...

  2. Testing to expand the rotary-mode core sampling system operating envelope

    International Nuclear Information System (INIS)

    Witwer, K.S.

    1998-01-01

    Rotary sampling using the Rotary Mode Core Sampling System (RMCSS) is constrained by what is referred to as the ''Operating Envelope''. The Operating Envelop defines the maximum downward force, maximum rotational speed and minimum purge gas flow allowed during operation of the RMCSS. The original values of 1170 lb. down force, 55 RPM rotational speed, and 30 SCFM nitrogen purge gas were determined during original envelope testing. This envelope was determined by observing the temperature rise on the bitface while drilling into waste simulants. The maximum temperature in single-shell tanks (SSTS) is considered to be approximately 9O C and the critical drill bit temperature, which is the temperature at which an exothermic reaction could be initiated in the tank waste, was previously determined to be 150 C. Thus, the drill bit temperature increase was limited to 60 C. Thermal properties of these simulants approximated typical properties of waste tank saltcake. Later, more detailed envelope testing which used a pumice block simulant, showed a notably higher temperature rise while drilling. This pumice material, which simulated a ''worst case'' foreign object embedded in the waste, has lower thermal conductivity and lower thermal diffusivity than earlier simulants. These properties caused a slower heat transfer in the pumice than in the previous simulants and consequently a higher temperature rise. The maximum downward force was subsequently reduced to 750 lb (at a maximum 55 RPM and minimum 30 SCFM purge gas flow) which was the maximum value at which the drill bit could be operated and still remain below the 60 C temperature rise

  3. Percutaneous nephrolithotomy in children: A preliminary report

    Directory of Open Access Journals (Sweden)

    Ahmad A. Elderwy

    2014-01-01

    Full Text Available Objectives: The recurrence of pediatric nephrolithiasis, the morbidity of repeated open surgical treatment as well as our experience in percutaneous nephrolithotomy (PNL in adult patients, all derived us to shift to PNL for managing renal stones >1.5 cm in pediatric patients. Our aim of this study is to evaluate the safety and efficacy of PNL in pediatric patients. Materials and Methods: During the period of the month between May 2011 and April 2013, 38 children (47 renal units underwent PNL for renal stones 1.5-5 cm in length. Patient demographics, stone characteristics, and clinical outcome were prospectively studied. Data of those who underwent conventional and tubeless PNL were compared. Median follow-up period was 12 months (range: 6-24. Results: The median age at presentation was 8-year (range: 3-12. The operative time ranged from 30 to 120 min (median 90. Overall stone clearance rate was 91.5% after single PNL. The median hospital stay was 3 days. Auxiliary procedures were successful for the remaining 4 patients (nephroscopic clearance in one and shockwave lithotripsy in 3. Tubeless PNL was performed in 17 renal units with a comparable outcome to conventional ones. The perioperative complications were noted in 5/47 (10.6% of all procedures (Clavien Grade II in 4 and Clavien Grade IIIa in 1 and were managed conservatively. Conclusions: Percutaneous nephrolithotomy for renal stones in pediatric patients is safe and feasible if performed by a well-experienced endourologist. Tubeless PNL is a better choice for children.

  4. Tank 241-AZ-101 and tank 241-AZ-102, airlift circulator operation vapor sampling and analysis plan

    International Nuclear Information System (INIS)

    TEMPLETON, A.M.

    1999-01-01

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of the tank 241-AZ-101 and 241-AZ-102 airlift circulators (ALCs). The purpose of the ALC operation is to support portions of the operational test procedure (OTP) for Project W-030 (OTP-W030-001) and to perform functional test in support of Project W-151. Project W-030 is the 241-A-702 ventilation upgrade project (241-AZ-702) and Project W-151 is the 241-AZ-101 Mixer Pump Test. The functional tests will check the operability of the tank 241-AZ-101 ALCs. Process Memo's No.2E98-082 and No.2E99-001 (LMHC 1999a, LMHC 1999b) direct the operation of the ALCs and the Industrial Hygiene monitoring respectively. A series of tests will be conducted in which the ALCs in tanks 241-AZ-101 and 241-AZ-102 will be operated at different air flow rates. Vapor samples will be obtained to determine constituents that may be present in the tank headspace during ALC operation at tanks 241-AZ-101 and 241-AZ-102 as the waste is disturbed. During the testing, vapor samples will be obtained from the headspace of tanks 241-AZ-101 and 241-AZ-102 via the unused port on the standard hydrogen monitoring system (SHMS). Results will be used to provide the waste feed delivery program with environmental air permitting data for tank waste disturbing activities. Because of radiological concerns, the samples will be filtered for particulates. It is recognized that this may remove some organic compounds

  5. Impact of stone branch number on outcomes of percutaneous nephrolithotomy for treatment of staghorn calculi.

    Science.gov (United States)

    Qi, Shiyong; Li, Li; Liu, Ranlu; Qiao, Baomin; Zhang, Zhihong; Xu, Yong

    2014-02-01

    To determine the impact of staghorn calculi branch number on outcomes of percutaneous nephrolithotomy (PNL). Retrospectively, we evaluated 371 patients (386 renal units) who underwent PNL for staghorn calculi. All calculi were showed with CT three-dimensional reconstruction (3DR) imaging preoperatively. From 3DR images, the number of stone branching into minor renal calices was recorded. According to the number, patients were divided into four groups. Group 1: the branch number 2-4; Group 2: the branch number 5-7; Group 3: the branch number 8-10; Group 4: the branch number >10. The number of percutaneous tract, operative time, staged PNL, intraoperative blood loss, postoperative hospital stay, complications, main stone composition, and stone clearance rate were compared. A significantly higher ratio of multitract (pPNL (pPNL for calculi with a stone branch number ≥5. There was no statistical difference in intraoperative blood loss (p=0.101) and main stone composition (p=0.546). There was no statistically meaningful difference among the four groups based on the Clavien complication system (p=0.46). With the stone branch number more than five, the possibility of multitract and staged PNL, lower rate of stone clearance, and a longer postoperative hospital stay increases for staghorn calculi.

  6. Hanford Internal Dosimetry Program Manual, PNL-MA-552

    Energy Technology Data Exchange (ETDEWEB)

    Carbaugh, Eugene H.; Bihl, Donald E.; Maclellan, Jay A.

    2009-09-24

    This manual is a guide to the services provided by the Hanford Internal Dosimetry Program (IDP), which is operated by the Pacific Northwest National Laboratory.( ) for the U.S. Department of Energy Richland Operations Office, Office of River Protection and their Hanford Site contractors. The manual describes the roles of and relationships between the IDP and the radiation protection programs of the Hanford Site contractors. Recommendations and guidance are also provided for consideration in implementing bioassay monitoring and internal dosimetry elements of radiation protection programs.

  7. Data validation summary report for the 100-BC-5 Operable Unit Round 8 Groundwater Sampling

    International Nuclear Information System (INIS)

    Kearney, A.T.

    1996-03-01

    The information provided in this validation summary report includes data from the chemical analyses of samples from the 100-BC-5 Operable Unit Round 8 Groundwater Sampling Investigation. All of the data from this sampling event and their related quality assurance samples were reviewed and validated to verify that the reported sample results were of sufficient quality to support decisions regarding remedial actions performed at this site. Sample analyses included metals, general chemistry and radiochemistry

  8. Sample Size of One: Operational Qualitative Analysis in the Classroom

    Directory of Open Access Journals (Sweden)

    John Hoven

    2015-10-01

    Full Text Available Qualitative analysis has two extraordinary capabilities: first, finding answers to questions we are too clueless to ask; and second, causal inference – hypothesis testing and assessment – within a single unique context (sample size of one. These capabilities are broadly useful, and they are critically important in village-level civil-military operations. Company commanders need to learn quickly, "What are the problems and possibilities here and now, in this specific village? What happens if we do A, B, and C?" – and that is an ill-defined, one-of-a-kind problem. The U.S. Army's Eighty-Third Civil Affairs Battalion is our "first user" innovation partner in a new project to adapt qualitative research methods to an operational tempo and purpose. Our aim is to develop a simple, low-cost methodology and training program for local civil-military operations conducted by non-specialist conventional forces. Complementary to that, this paper focuses on some essential basics that can be implemented by college professors without significant cost, effort, or disruption.

  9. Implementation of conduct of operations at Paducah uranium hexafluoride (UF{sub 6}) sampling and transfer facility

    Energy Technology Data Exchange (ETDEWEB)

    Penrod, S.R. [Martin Marietta Energy Systems, Inc., KY (United States)

    1991-12-31

    This paper describes the initial planning and actual field activities associated with the implementation of {open_quotes}Conduct of Operations{close_quotes}. Conduct of Operations is an operating philosophy that was developed through the Institute of Nuclear Power Operations (INPO). Conduct of Operations covers many operating practices and is intended to provide formality and discipline to all aspects of plant operation. The implementation of these operating principles at the UF{sub 6} Sampling and Transfer Facility resulted in significant improvements in facility operations.

  10. Implementation of conduct of operations at Paducah uranium hexafluoride (UF{sub 6}) sampling and transfer facility

    Energy Technology Data Exchange (ETDEWEB)

    Penrod, S.R. [Martin Marietta Energy Systems, Inc., KY (United States)

    1991-12-31

    This paper describes the initial planning and actual field activities associated with the implementation of {open_quotes}Conduct of Operations{close_quotes}, Conduct of Operations is an operating philosophy that was developed through the Institute of Nuclear Power Operations (INPO). Conduct of Operations covers many operating practices and is intended to provide formality and discipline to all aspects of plant operation. The implementation of these operating principles at the UF{sub 6} Sampling and Transfer Facility resulted in significant improvements in facility operations.

  11. Comparison of supine and prone positions for percutaneous nephrolithotomy in treatment of staghorn stones.

    Science.gov (United States)

    Gökce, Mehmet İlker; Ibiş, Arif; Sancı, Adem; Akıncı, Aykut; Bağcı, Uygar; Ağaoğlu, Eylül Asya; Süer, Evren; Gülpınar, Ömer

    2017-12-01

    Percutaneous nephrolithotomy (PNL) is the primary treatment modality for management of staghorn stones. PNL in supine position has important advantages over prone positon. However, studies comparing prone and supine positions for PNL in staghorn stone patients have conflicting results, and the aim of the current study was to compare prone and supine positions for PNL in staghorn stone cases. Data of patients underwent PNL for staghorn stones in supine or prone position by a single urologist were collected prospectively. The supine and prone position groups were compared for stone free rate (SFR) and complication rates. All patients were evaluated with NCCT for evaluation of SFR. Chi-square test was used to compare categorical variables and Student t test was applied for continuous variables of the treatment groups. The groups were similar for demographic and stone-related characteristics. Multi-caliceal and intercostal access was more common in prone position. Operation duration was significantly shorter and hemoglobin drop was significantly less in supine group. SFR was 64.1 and 60.4% in the supine and prone groups, respectively (p = 0.72). Complication rates were similar in the two groups but Clavien III complications were observed in two patients in the prone group. PNL in supine position is an effective treatment for management of staghorn stones. The need for multi-caliceal and intercostal puncture is less when combined with retrograde intrarenal surgery. PNL in supine position should be considered as primary treatment option in staghorn stone cases.

  12. Sampling and Analysis Plan Update for Groundwater Monitoring 1100-EM-1 Operable Unit

    International Nuclear Information System (INIS)

    DR Newcomer

    1999-01-01

    This document updates the sampling and analysis plan (Department of Energy/Richland Operations--95-50) to reflect current groundwater monitoring at the 1100-EM-1Operable Unit. Items requiring updating included sampling and analysis protocol, quality assurance and quality control, groundwater level measurement procedure, and data management. The plan covers groundwater monitoring, as specified in the 1993 Record of Decision, during the 5-year review period from 1995 through 1999. Following the 5-year review period, groundwater-monitoring data will be reviewed by Environmental Protection Agency to evaluate the progress of natural attenuation of trichloroethylene. Monitored natural attenuation and institutional controls for groundwater use at the inactive Horn Rapids Landfill was the selected remedy specified in the Record of Decision

  13. Comparison of flexible ureterorenoscopy and mini-percutaneous nephrolithotomy in treatment of lower calyceal stones smaller than 2 cm.

    Science.gov (United States)

    Akbulut, Fatih; Kucuktopcu, Onur; Kandemir, Emre; Sonmezay, Erkan; Simsek, Abdulmuttalip; Ozgor, Faruk; Binbay, Murat; Muslumanoglu, Ahmet Yaser; Gurbuz, Gokhan

    2016-01-01

    To compare the outcomes of flexible ureterorenoscopy (F-URS) and mini-percutaneous nephrolithotomy (mini-PNL) in the treatment of lower calyceal stones smaller than 2 cm. Patients who underwent F-URS and mini-PNL for the treatment of lower calyceal stones smaller than 2 cm between March 2009 and December 2014 were retrospectively evaluated. Ninety-four patients were divided into two groups by treatment modality: F-URS (Group 1: 63 patients) and mini-PNL (Group 2: 31 patients). All patients were preoperatively diagnosed with intravenous pyelography or computed tomography. Success rates for F-URS and mini-PNL at postoperative first month were 85.7% and 90.3%, respectively. Operation time, fluoroscopy time, and hospitalization time for F-URS and mini-PNL patients were 44.40 min, 2.9 min, 22.4 h, and 91.9 min, 6.4 min, and 63.8 h, respectively. All three parameters were significantly shorter among the F-URS group (p PNL group (0.39 mg/dL vs. 1.15 mg/dL, p = 0.001). A comparison of complications according to the Clavien classification demonstrated significant differences between the groups (p = 0.001). More patients in the F-URS groups require antibiotics due to urinary tract infection, and more patients in the mini-PNL group required ureteral double J catheter insertion under general anesthesia. Although both F-URS and mini-PNL have similar success rates for the treatment of lower calyceal stones, F-URS appears to be more favorable due to shorter fluoroscopy and hospitalization times; and lower hemoglobin drops. Multicenter and studies using higher patient volumes are needed to confirm these findings.

  14. Structural evaluation for the core sampling trucks, RMCS operations, 200 Area

    International Nuclear Information System (INIS)

    Islam, M.A.

    1996-01-01

    This report evaluates the structural adequacy and the integrity of the existing core sampling trucks to withstand impact should the trucks drop off the ramp, either onto the soft ground or onto a non-yielding surface due to operational error, wind, or earthquake. The report also addresses if the allowable tank dome load will be exceeded by the addition of the impact load

  15. N Reactor thermal plume characterization during Pu-only mode of operation

    Energy Technology Data Exchange (ETDEWEB)

    Ecker, R.M.; Thompson, F.L.; Whelan, G.

    1983-04-01

    Pacific Northwest Laboratories (PNL) performed field and modeling studies -from March 1982 through June 1983 to characterize the thermal plume from the N Reactor heated water outfall while the N Reactor operated in the Pu-only mode. Part 1 of this report deals with the field studies conducted to characterize the N Reactor thermal plume while in the Pu-only mode of operation. It includes a description of the study area, a description of field tasks and procedures, and data collection results and discussion. Part 2 describes the computer simulation of the thermal plume under different flow conditions and the calibration of the model used. It includes a description of the computer model and the assumptions on which it is based, a presentation of the input data used in this application, and a discussion of modeling results. Because the field studies were restricted by the NPOES permit variance to the spring months when high Columbia River flows prevail the mathematical modeling of the N Reactor thermal plume while the reactor operates in the Pu-only mode is instrumental in characterizing the plume during low Columbia River flows.

  16. Air sampling procedures to evaluate microbial contamination: a comparison between active and passive methods in operating theatres.

    Science.gov (United States)

    Napoli, Christian; Marcotrigiano, Vincenzo; Montagna, Maria Teresa

    2012-08-02

    Since air can play a central role as a reservoir for microorganisms, in controlled environments such as operating theatres regular microbial monitoring is useful to measure air quality and identify critical situations. The aim of this study is to assess microbial contamination levels in operating theatres using both an active and a passive sampling method and then to assess if there is a correlation between the results of the two different sampling methods. The study was performed in 32 turbulent air flow operating theatres of a University Hospital in Southern Italy. Active sampling was carried out using the Surface Air System and passive sampling with settle plates, in accordance with ISO 14698. The Total Viable Count (TVC) was evaluated at rest (in the morning before the beginning of surgical activity) and in operational (during surgery). The mean TVC at rest was 12.4 CFU/m3 and 722.5 CFU/m2/h for active and passive samplings respectively. The mean in operational TVC was 93.8 CFU/m3 (SD = 52.69; range = 22-256) and 10496.5 CFU/m2/h (SD = 7460.5; range = 1415.5-25479.7) for active and passive samplings respectively. Statistical analysis confirmed that the two methods correlate in a comparable way with the quality of air. It is possible to conclude that both methods can be used for general monitoring of air contamination, such as routine surveillance programs. However, the choice must be made between one or the other to obtain specific information.

  17. Rupture of plutonium oxide storage container, March 13, 1979

    Energy Technology Data Exchange (ETDEWEB)

    1979-05-29

    On March 13, 1979, a plutonium oxide storage can ruptured in the 303-C storage facility, which is in the 300 Area of the Hanford Site, Washington. The facility is operated by the Pacific Northwest Laboratory (PNL); three PNL staff members were performing the storage operation. No injuries to these staff members resulted from the occurrence. A Class C Investigation Committee was appointed on March 14, 1979, by the Director, PNL. Subsequently, when the loss estimates became available, the Manager, Department of Energy-Richland Operations Office (DOE-RL), appointed a Class B Investigation Committee in accordance with DOE Manual Chapter 0502. As requested by DOE-RL, the Committee investigated technical elements of the causal sequence and management systems that should have or could have prevented the occurrence. The investigation included: review of the use of the 303-C facilities and the transfer containers; interviews with the involved personnel and their managers; analysis of technical studies related to involved materials and procedures; review of safe operating procedures, radiation work procedures, and transfer requirements applicable to the occurrence; and use of the Management Oversight and Risk Tree (MORT) and the Events and Causal Factors Charting methods. 15 figs.

  18. Visual Sample Plan (VSP) Software: Designs and Data Analyses for Sampling Contaminated Buildings

    International Nuclear Information System (INIS)

    Pulsipher, Brent A.; Wilson, John E.; Gilbert, Richard O.; Nuffer, Lisa L.; Hassig, Nancy L.

    2005-01-01

    A new module of the Visual Sample Plan (VSP) software has been developed to provide sampling designs and data analyses for potentially contaminated buildings. An important application is assessing levels of contamination in buildings after a terrorist attack. This new module, funded by DHS through the Combating Terrorism Technology Support Office, Technical Support Working Group, was developed to provide a tailored, user-friendly and visually-orientated buildings module within the existing VSP software toolkit, the latest version of which can be downloaded from http://dqo.pnl.gov/vsp. In case of, or when planning against, a chemical, biological, or radionuclide release within a building, the VSP module can be used to quickly and easily develop and visualize technically defensible sampling schemes for walls, floors, ceilings, and other surfaces to statistically determine if contamination is present, its magnitude and extent throughout the building and if decontamination has been effective. This paper demonstrates the features of this new VSP buildings module, which include: the ability to import building floor plans or to easily draw, manipulate, and view rooms in several ways; being able to insert doors, windows and annotations into a room; 3-D graphic room views with surfaces labeled and floor plans that show building zones that have separate air handing units. The paper will also discuss the statistical design and data analysis options available in the buildings module. Design objectives supported include comparing an average to a threshold when the data distribution is normal or unknown, and comparing measurements to a threshold to detect hotspots or to insure most of the area is uncontaminated when the data distribution is normal or unknown

  19. Cesium relocation in mixed-oxide fuel pins resulting from increased temperature reirradiation

    International Nuclear Information System (INIS)

    Lawrence, L.A.; Woodley, R.E.; Weber, E.T.

    1976-06-01

    Mixed-oxide fuel pins from EBR-II test subassemblies PNL-3 and PNL-4 were reirradiated in the GETR to study effects of increased fuel and cladding temperatures on chemical and thermomechanical behavior. Radial and axial distributions of cesium were obtained using postirradiation nondestructive precision gamma-scanning techniques. Data presented relate to the dependence of cesium distribution and transport processes on temperature gradients which were altered after substantial steady-state operation

  20. Predictors of radiation exposure to providers during percutaneous nephrolithotomy

    OpenAIRE

    David L Wenzler; Joel E Abbott; Jeannie J Su; William Shi; Richard Slater; Daniel Miller; Michelle J Siemens; Roger L Sur

    2017-01-01

    Background: Limited studies have reported on radiation risks of increased ionizing radiation exposure to medical personnel in the urologic community. Fluoroscopy is readily used in many urologic surgical procedures. The aim of this study was to determine radiation exposure to all operating room personnel during percutaneous nephrolithotomy (PNL), commonly performed for large renal or complex stones. Materials and Methods: We prospectively collected personnel exposure data for all PNL cases at...

  1. Designing an enhanced groundwater sample collection system

    International Nuclear Information System (INIS)

    Schalla, R.

    1994-10-01

    As part of an ongoing technical support mission to achieve excellence and efficiency in environmental restoration activities at the Laboratory for Energy and Health-Related Research (LEHR), Pacific Northwest Laboratory (PNL) provided guidance on the design and construction of monitoring wells and identified the most suitable type of groundwater sampling pump and accessories for monitoring wells. The goal was to utilize a monitoring well design that would allow for hydrologic testing and reduce turbidity to minimize the impact of sampling. The sampling results of the newly designed monitoring wells were clearly superior to those of the previously installed monitoring wells. The new wells exhibited reduced turbidity, in addition to improved access for instrumentation and hydrologic testing. The variable frequency submersible pump was selected as the best choice for obtaining groundwater samples. The literature references are listed at the end of this report. Despite some initial difficulties, the actual performance of the variable frequency, submersible pump and its accessories was effective in reducing sampling time and labor costs, and its ease of use was preferred over the previously used bladder pumps. The surface seals system, called the Dedicator, proved to be useful accessory to prevent surface contamination while providing easy access for water-level measurements and for connecting the pump. Cost savings resulted from the use of the pre-production pumps (beta units) donated by the manufacturer for the demonstration. However, larger savings resulted from shortened field time due to the ease in using the submersible pumps and the surface seal access system. Proper deployment of the monitoring wells also resulted in cost savings and ensured representative samples

  2. Preliminary evaluation of PSCM and BIPP melter design and operating conditions using physical modeling

    International Nuclear Information System (INIS)

    Skarda, R.J.; Hauser, S.G.; Fort, J.A.

    1985-05-01

    The Glass Melter Physical Modeling investigation was initiated to support Pacific Northwest Laboratory (PNL) Hanford Waste Vitrification Program. Specifically, results discussed herein are those of the modeled B-Plant Immobilization Pilot Plant (BIPP) and Pilot Scale Ceramic Melter (PSCM) designs. The purpose of this study was to evaluate various melter design features using laboratory scale models. Hydrodynamic, thermal, and electrical similarity between the modeling fluid and the molten glass were primary objectives. Stroboscopic velocity measurements (flow visualization), temperature measurements, and electrical potential measurements were used to investigate the molten glass behavior. Results from this effort are to provide input to melter design and proposed operation in addition to providing a data base for verifying numerical models. 13 refs., 48 figs., 24 tabs

  3. Turbulent wind at the equatorial segment of an operating Darrieus wind turbine blade

    Science.gov (United States)

    Connell, J. R.; Morris, V. R.

    1989-09-01

    Six turbulent wind time series, measured at equally spaced equator-height locations on a circle 3 m outside a 34-m Darrieus rotor, are analyzed to approximate the wind fluctuations experienced by the rotor. The flatwise lower root-bending stress of one blade was concurrently recorded. The wind data are analyzed in three ways: wind components that are radial and tangential to the rotation of a blade were rotationally sampled; induction and wake effects of the rotor were estimated from the six Eulerian time series; and turbulence spectra of both the measured wind and the modeled wind from the PNL theory of rotationally sampled turbulence. The wind and the rotor response are related by computing the spectral response function of the flatwise lower root-bending stress. Two bands of resonant response that surround the first and second flatwise modal frequencies shift with the rotor rotation rate.

  4. Air sampling procedures to evaluate microbial contamination: a comparison between active and passive methods in operating theatres

    Directory of Open Access Journals (Sweden)

    Napoli Christian

    2012-08-01

    Full Text Available Abstract Background Since air can play a central role as a reservoir for microorganisms, in controlled environments such as operating theatres regular microbial monitoring is useful to measure air quality and identify critical situations. The aim of this study is to assess microbial contamination levels in operating theatres using both an active and a passive sampling method and then to assess if there is a correlation between the results of the two different sampling methods. Methods The study was performed in 32 turbulent air flow operating theatres of a University Hospital in Southern Italy. Active sampling was carried out using the Surface Air System and passive sampling with settle plates, in accordance with ISO 14698. The Total Viable Count (TVC was evaluated at rest (in the morning before the beginning of surgical activity and in operational (during surgery. Results The mean TVC at rest was 12.4 CFU/m3 and 722.5 CFU/m2/h for active and passive samplings respectively. The mean in operational TVC was 93.8 CFU/m3 (SD = 52.69; range = 22-256 and 10496.5 CFU/m2/h (SD = 7460.5; range = 1415.5-25479.7 for active and passive samplings respectively. Statistical analysis confirmed that the two methods correlate in a comparable way with the quality of air. Conclusion It is possible to conclude that both methods can be used for general monitoring of air contamination, such as routine surveillance programs. However, the choice must be made between one or the other to obtain specific information.

  5. Status of automated tensile machine

    International Nuclear Information System (INIS)

    Satou, M.; Hamilton, M.L.; Sato, S.; Kohyama, A.

    1992-01-01

    The objective of this work is to develop the Monbusho Automated Tensile machine (MATRON) and install and operate it at the Pacific Northwest Laboratory (PNL). The machine is designed to provide rapid, automated testing of irradiated miniature tensile specimen in a vacuum at elevated temperatures. The MATRON was successfully developed and shipped to PNL for installation in a hot facility. The original installation plan was modified to simplify the current and subsequent installations, and the installation was completed. Detailed procedures governing the operation of the system were written. Testing on irradiated miniature tensile specimen should begin in the near future

  6. Soil Sampling Operating Procedure

    Science.gov (United States)

    EPA Region 4 Science and Ecosystem Support Division (SESD) document that describes general and specific procedures, methods, and considerations when collecting soil samples for field screening or laboratory analysis.

  7. Barriers to development and deployment of innovative waste minimization technologies

    International Nuclear Information System (INIS)

    Flores, E.A.; Donaghue, J.F.

    1994-08-01

    Increasing regulation and scrutiny is driving waste generators towards reducing the use of scarce natural resources and reducing or eliminating was streams. There is increasing emphasis on developing and deploying technologies that meet industry needs for recovering valuable materials in a cost-effective manner. At the Department of Energy's (DOE) Hanford Site, Battelle operates Pacific Northwest Laboratory (PNL). PNL's mission is to develop technologies to clean up the environment, and to assist industry in being competitive on a global scale. One such technology developed by PNL is the Waste Acid Detoxification and Reclamation (WADR) process. This technology recovers acids from metal-bearing spent solutions, separating out the metals (which are a valuable byproduct of the acid recycling operation) from the acids. WADR uses selective precipitation and distillation together in an innovative waste recycling technology. Selective precipitation removes the heavy metals, and vacuum distillation recovers clean acid. However, WADR and other innovative waste reduction technologies face numerous barriers to successful development and deployment in the field

  8. Hanford Site environmental data for calendar year 1989, surface and Columbia River

    International Nuclear Information System (INIS)

    Bisping, L.E.; Woodruff, R.K.

    1990-06-01

    Environmental monitoring at the Hanford Site, located in southeastern Washington State, is conducted by Battelle Memorial Institute, Pacific Northwest Division, as part of its contract to operate the Pacific Northwest Laboratory (PNL) for the US Department of Energy. The data collected provide a historical record of radionuclide and radiation levels attributable to natural causes, worldwide fallout, and Hanford operations. Data are also collected to monitor chemicals on the site and in the Columbia River. Pacific Northwest Laboratory publishes an annual environmental report Hanford Site Environmental Report for Calendar Year 1989. That report is a comprehensive source of offsite and onsite environmental monitoring data collected during 1989 by PNL's Environmental Monitoring Program. Appendix C of that report contains data summaries created from raw surface and river monitoring data. This volume contains the actual raw data used to create the summaries. Ground-water monitoring data will be available separately. Questions concerning the data appearing here can be directed to R. K. Woodruff, PNL Project Manager, Surface Environmental Surveillance Project

  9. Melter viewing system for liquid-fed ceramic melters

    International Nuclear Information System (INIS)

    Westsik, J.H. Jr.; Brenden, B.B.

    1988-01-01

    Melter viewing systems are an integral component of the monitoring and control systems for liquid-fed ceramic melters. The Pacific Northwest Laboratory (PNL) has designed cameras for use with glass melters at PNL, the Hanford Waste Vitrification Plant (HWVP), and West Valley Demonstration Project (WVDP). This report is a compilation of these designs. Operating experiences with one camera designed for the PNL melter are discussed. A camera has been fabricated and tested on the High-Bay Ceramic Melter (HBCM) and the Pilot-Scale Ceramic Melter (PSCM) at PNL. The camera proved to be an effective tool for monitoring the cold cap formed as the feed pool developed on the molten glass surface and for observing the physical condition of the melter. Originally, the camera was built to operate using the visible light spectrum in the melter. It was later modified to operate using the infrared (ir) spectrum. In either configuration, the picture quality decreases as the size of the cold cap increases. Large cold caps cover the molten glass, reducing the amount of visible light and reducing the plenum temperatures below 600 0 C. This temperature corresponds to the lowest level of blackbody radiation to which the video tube is sensitive. The camera has been tested in melter environments for about 1900 h. The camera has withstood mechanical shocks and vibrations. The cooling system in the camera has proved effective in maintaining the optical and electronic components within acceptable temperature ranges. 10 refs., 15 figs

  10. Review of light water reactor regulatory requirements: Assessment of selected regulatory requirements that may have marginal importance to risk: Postaccident sampling system, Turbine missiles, Combustible gas control, Charcoal filters

    International Nuclear Information System (INIS)

    Scott, W.B.; Jamison, J.D.; Stoetzel, G.A.; Tabatabai, A.S.; Vo, T.V.

    1987-05-01

    In a study commissioned by the Nuclear Regulatory Commission (NRC), Pacific Northwest Laboratory (PNL) evaluated the costs and benefits of modifying regulatory requirements in the areas of the postaccident sampling system, turbine rotor design reviews and inspections, combustible gas control for inerted Boiling Water Reactor (BWR) containments, and impregnated charcoal filters in certain plant ventilation systems. The basic framework for the analyses was that presented in the Regulatory Analysis Guidelines (NUREG/BR-0058) and in the Handbook for Value-Impact Assessment (NUREG/CR-3568). The effects of selected modifications to regulations were evaluated in terms of such factors as public risk and costs to industry and NRC. The results indicate that potential modifications of the regulatory requirements in three of the four areas would have little impact on public risk. In the fourth area, impregnated charcoal filters in building ventilation systems do appear to limit risks to the public and plant staff. Revisions in the severe accident source term assumptions, however, may reduce the theoretical value of charcoal filters. The cost analysis indicated that substantial savings in operating costs may be realized by changing the interval of turbine rotor inspections. Small to moderate operating cost savings may be realized through postulated modifications to the postaccident sampling system requirements and to the requirements for combustible gas control in inerted BWR containments. Finally, the use of impregnated charcoal filters in ventilation systems appears to be the most cost-effective method of reducing radioiodine concentrations

  11. Determination of Initial Conditions for the Safety Analysis by Random Sampling of Operating Parameters

    International Nuclear Information System (INIS)

    Jeong, Hae-Yong; Park, Moon-Ghu

    2015-01-01

    In most existing evaluation methodologies, which follow a conservative approach, the most conservative initial conditions are searched for each transient scenario through tremendous assessment for wide operating windows or limiting conditions for operation (LCO) allowed by the operating guidelines. In this procedure, a user effect could be involved and a remarkable time and human resources are consumed. In the present study, we investigated a more effective statistical method for the selection of the most conservative initial condition by the use of random sampling of operating parameters affecting the initial conditions. A method for the determination of initial conditions based on random sampling of plant design parameters is proposed. This method is expected to be applied for the selection of the most conservative initial plant conditions in the safety analysis using a conservative evaluation methodology. In the method, it is suggested that the initial conditions of reactor coolant flow rate, pressurizer level, pressurizer pressure, and SG level are adjusted by controlling the pump rated flow, setpoints of PLCS, PPCS, and FWCS, respectively. The proposed technique is expected to contribute to eliminate the human factors introduced in the conventional safety analysis procedure and also to reduce the human resources invested in the safety evaluation of nuclear power plants

  12. Low-sensitivity H ∞ filter design for linear delta operator systems with sampling time jitter

    Science.gov (United States)

    Guo, Xiang-Gui; Yang, Guang-Hong

    2012-04-01

    This article is concerned with the problem of designing H ∞ filters for a class of linear discrete-time systems with low-sensitivity to sampling time jitter via delta operator approach. Delta-domain model is used to avoid the inherent numerical ill-condition resulting from the use of the standard shift-domain model at high sampling rates. Based on projection lemma in combination with the descriptor system approach often used to solve problems related to delay, a novel bounded real lemma with three slack variables for delta operator systems is presented. A sensitivity approach based on this novel lemma is proposed to mitigate the effects of sampling time jitter on system performance. Then, the problem of designing a low-sensitivity filter can be reduced to a convex optimisation problem. An important consideration in the design of correlation filters is the optimal trade-off between the standard H ∞ criterion and the sensitivity of the transfer function with respect to sampling time jitter. Finally, a numerical example demonstrating the validity of the proposed design method is given.

  13. Percutaneous Nephrolithotomy for Kidney Stones in Patients with Hematological Malignancy

    Directory of Open Access Journals (Sweden)

    Baris Kuzgunbay

    2016-07-01

    Full Text Available Aim: To define the alterations in the outcomes of percutaneous nephrolithotomy (PNL operations for kidney stones in patients with history of hematological malignancy (HM. Material and Method: Between 2000 and 2013, 1700 adult patients underwent PNL for the treatment of kidney stones in our institution. Four of these patients had a history of HM and considered to be HM group (n=4. Ten elderly (>65 years patients who had no history of operation, HM or any other co-morbide diseases were chosen as the control group (n=10. Surgical parameters, success rates, additional treatments and complications were evaluated. Results: Statistical analyses showed no significant differences between HM and control group according to stone area, operation time, fluoroscopy time, hospitalization time, %u2206Hb, blood transfusion rates and INR values (p>0.05. Statistical analyses revealed no significant differences between HM and control groups according to the success rates (p=0.470. Statistical analyses revealed no significant difference between groups for additional treatment requirements (p=0.882. No major perioperative complication was seen in both of the groups. Discussion: The treatment of kidney stone disease by PNL in patients with hematological malignancy is feasible, safe and effective. However, close cooperation with the Hematology Department before the operation is mandatory.

  14. Performance of some silver sorbents for control of radioiodine from nuclear fuel operations

    International Nuclear Information System (INIS)

    Scheele, R.D.; Burger, L.L.; Halko, B.T.; Waters, E.D.; Orme, R.M.

    1989-01-01

    The Process Facility Modification (PFM) proposed for the Hanford PUREX plant includes control of gaseous radioiodine. In support of the Westinghouse Hanford Company (WHC) design effort for the PFM, the Pacific Northwest Laboratory (PNL) has evaluated caustic scrubbing and the use of silver-containing solid sorbents to remove iodine from the dissolver offgas (DOG) stream. The present report describes the behavior of several silver-containing zeolites and silver nitrate-impregnated silicic acid tested under conditions simulating normal and standby operation of the PFM. These studies found that the silver zeolites, Norton silver mordenite (NAgZ), Linde silver mordenite (LAgZ), and partially silver-exchanged Linde silver faujasite (PAgX), can routinely reduce the gaseous iodine concentration in a simulated PFM DOG to -5 μmol I/L, while a commercially produced silver nitrate-impregnated silicic acid (AgNO 3 Si) could not at these test conditions. Tests simulating standby operation of beds loaded up to 0.25 μmol I/g sorbent indicate that standby operation will not result in effluent concentrations above 10 -5 μmol I/L. At higher loadings standby operation initially caused iodine to migrate from NAgZ. There were indications that the iodine tends to stabilize with time, but insufficient information is available to fully characterize these reactions

  15. Uranium recovery research sponsored by the Nuclear Regulatory Commission at Pacific Northwest Laboratory. Annual progress report, May 1982-May 1983

    International Nuclear Information System (INIS)

    Foley, M.G.; Opitz, B.E.; Deutsch, W.J.

    1983-06-01

    Pacific Northwest Laboratory (PNL) is currently conducting research for the US Nuclear Regulatory Commission (NRC) on uranium recovery process wastes for both active and inactive operations. NRC-sponsored uranium recovery research at PNL is focused on NRC regulatory responsibilities for uranium-recovery operations: license active milling and in situ extraction operations; concur on the acceptability of DOE remedial-action plans for inactive sites; and license DOE to maintain inactive sites following remedial actions. PNL's program consists of four coordinated projects comprised of a program management task and nine research tasks that address the critical technical and safety issues for uranium recovery. Specifically, the projects endeavor to find and evaluate methods to: prevent erosion of tailings piles and prevent radon release from tailings piles; evaluate the effectiveness of interim stabilization techniques to prevent wind erosion and transport of dry tailings from active piles; estimate the dewatering and consolidation behavior of slurried tailings to promote early cover placement; design a cover-protection system to prevent erosion of the cover by expected environmental stresses; reduce seepage into ground water and prevent ground-water degradation; control solution movement and reaction with ground water in in-situ extraction operations; evaluate natural and induced restoration of ground water in in-situ extraction operations; and monitor releases to the environment from uranium recovery facilities

  16. Uranium recovery research sponsored by the Nuclear Regulatory Commission at Pacific Northwest Laboratory. Annual progress report, May 1982-May 1983

    Energy Technology Data Exchange (ETDEWEB)

    Foley, M.G.; Opitz, B.E.; Deutsch, W.J.; Peterson, S.R.; Gee, G.W.; Serne, R.J.; Hartley, J.N.; Thomas, V.W.; Kalkwarf, D.R.; Walters, W.H.

    1983-06-01

    Pacific Northwest Laboratory (PNL) is currently conducting research for the US Nuclear Regulatory Commission (NRC) on uranium recovery process wastes for both active and inactive operations. NRC-sponsored uranium recovery research at PNL is focused on NRC regulatory responsibilities for uranium-recovery operations: license active milling and in situ extraction operations; concur on the acceptability of DOE remedial-action plans for inactive sites; and license DOE to maintain inactive sites following remedial actions. PNL's program consists of four coordinated projects comprised of a program management task and nine research tasks that address the critical technical and safety issues for uranium recovery. Specifically, the projects endeavor to find and evaluate methods to: prevent erosion of tailings piles and prevent radon release from tailings piles; evaluate the effectiveness of interim stabilization techniques to prevent wind erosion and transport of dry tailings from active piles; estimate the dewatering and consolidation behavior of slurried tailings to promote early cover placement; design a cover-protection system to prevent erosion of the cover by expected environmental stresses; reduce seepage into ground water and prevent ground-water degradation; control solution movement and reaction with ground water in in-situ extraction operations; evaluate natural and induced restoration of ground water in in-situ extraction operations; and monitor releases to the environment from uranium recovery facilities.

  17. An innovative approach to sampling complex industrial emissions for use in animal toxicity tests: application to iron casting operations.

    Science.gov (United States)

    Palmer, W G; Scholz, R C; Moorman, W J

    1983-03-01

    Sampling of complex mixtures of airborne contaminants for chronic animal toxicity tests often involves numerous sampling devices, requires extensive sampling time, and yields forms of collected materials unsuitable for administration to animals. A method is described which used a high volume, wet venturi scrubber for collection of respirable fractions of emissions from iron foundry casting operations. The construction and operation of the sampler are presented along with collection efficiency data and its application to the preparation of large quantities of samples to be administered to animals by intratracheal instillation.

  18. Optimizing the data acquisition rate for a remotely controllable structural monitoring system with parallel operation and self-adaptive sampling

    International Nuclear Information System (INIS)

    Sheng, Wenjuan; Guo, Aihuang; Liu, Yang; Azmi, Asrul Izam; Peng, Gang-Ding

    2011-01-01

    We present a novel technique that optimizes the real-time remote monitoring and control of dispersed civil infrastructures. The monitoring system is based on fiber Bragg gating (FBG) sensors, and transfers data via Ethernet. This technique combines parallel operation and self-adaptive sampling to increase the data acquisition rate in remote controllable structural monitoring systems. The compact parallel operation mode is highly efficient at achieving the highest possible data acquisition rate for the FBG sensor based local data acquisition system. Self-adaptive sampling is introduced to continuously coordinate local acquisition and remote control for data acquisition rate optimization. Key issues which impact the operation of the whole system, such as the real-time data acquisition rate, data processing capability, and buffer usage, are investigated. The results show that, by introducing parallel operation and self-adaptive sampling, the data acquisition rate can be increased by several times without affecting the system operating performance on both local data acquisition and remote process control

  19. Laser alignment of rotating equipment at PNL

    International Nuclear Information System (INIS)

    Berndt, R.H.

    1994-05-01

    Lateral vibration in direct-drive equipment is usually caused by misalignment. Over the years, because of the need to improve on techniques and ways of working more efficiently, various types of alignment methods have evolved. In the beginning, craftsmen used a straight-edge scale across the coupling with a feeler gauge measuring the misalignment error. This is still preferred today for aligning small couplings. The industry has since decided that alignment of large direct-drive equipment needed a more accurate type of instrumentation. Rim and face is another of the first alignment methods and is used on all sizes of equipment. A disadvantage of the rim and face method is that in most cases the coupling has to be disassembled. This can cause alignment problems when the coupling is reassembled. Also, the rim and face method is not fast enough to work satisfactorily on alignment of thermally hot equipment. Another concern is that the coupling has to be manufactured accurately for correct rim and face readings. Reverse dial alignment is an improvement over the rim and face method, and depending on the operator's experience, this method can be very accurate. A good training program along with field experience will bring the operator to a proper level of proficiency for a successful program. A hand-held computer with reverse dial calculations in memory is a must for job efficiency. An advantage over the rim and face method is that the coupling is not disassembled and remains locked together. Reverse dial instrumentation measures from both shaft center lines, rather than the coupling surface so the machining of the coupling during manufacture is not a major concern

  20. Water born pollutants sampling using porous suction samples

    International Nuclear Information System (INIS)

    Baig, M.A.

    1997-01-01

    The common standard method of sampling water born pollutants in the vadoze zone is core sampling and it is followed by extraction of pore fluid. This method does not allow sampling at the same location next time and again later on. There is an alternative approach for sampling fluids (water born pollutants) from both saturated and unsaturated regions of vadose zone using porous suction samplers. There are three types of porous suction samplers, vacuum-operated, pressure-vacuum lysimeters, high pressure vacuum samples. The suction samples are operated in the range of 0-70 centi bars and usually consist of ceramic and polytetrafluorethylene (PTFE). The operation range of PTFE is higher than ceramic cups. These samplers are well suited for in situ and repeated sampling form the same location. This paper discusses the physical properties and operating condition of such samplers to the utilized under our environmental sampling. (author)

  1. Practice of Totally Tubeless Nephrolitotomy among Patients with Renal Calculus

    Directory of Open Access Journals (Sweden)

    Musa Ekici

    2013-08-01

    Full Text Available Purpose: We aimed to present the data on totally tubeless nephrolitotomy (PNL outcomes undergone in our clinic. Materials and Methods: We retrospectively analyzed 140 patients undergone totally tubeless PNL in our clinic between January 2010 and December 2012. Results: Mean patient age was 47,84 (5-73. Mean operative time was 88,8 (45-110 minutes where mean stone area was 375,3 (110-175 mm2 . 92,8% was our stone free rate. Remaining 10 patients had undergone ureterorenoscopy for ureteral stones. Two patients having non-opaque stones had residual kidney stones and treated by SWL. 8 patients (%5,7 needed blood transfusion, 2 patients needed perirenal hematoma and treated conservatively. No patients needed additional treatment or encountered vascular complications. One patient encountered serozal colon injury and treated conservatively. Conclusion: With regard to patient comfort, shorter hospital stay, low analgesic requirement, totally tubeless PNL gained popularity. We believe totally tubeless PNL may be used in suitable cases. Key Words: Kidney Stone, Totally Tubeless, Nephrolithotomy [Cukurova Med J 2013; 38(4.000: 636-641

  2. Our experience with percutaneous nephrolithotomy in pediatric renal stone disease.

    Science.gov (United States)

    Oral, İlknur; Nalbant, İsmail; Öztürk, Ufuk; Can Şener, Nevzat; Yeşil, Süleyman; Göksel Göktuğ, H N; Abdurrahim İmamoğlu, M

    2013-03-01

    In this paper, we present our experience with percutaneous nephrolithotomy (PNL) in a pediatric patient group. From June 2007 to September 2010, we performed PNL on 57 pediatric patients. children with a mean age of 7.56 (1-15) years. Study population consisted of 30 male, and 27 female children with a mean age of 7.56 (1-5) years. Mean stone burden was calculated to be 312.2 (95-1550) mm(2). Percutaneous access was performed under fluoroscopy. Tract dilatation was accomplished with 20 F Amplatz dilators. Pneumatic lithotripsy was used to fragment the renal calculi. Mean operating time was 34 (3-80) minutes. With a single session of PNL, complete stone-free rates were achieved in 55 (96.4%) patients. Residual fragments were remained in 2 (3.5%) patients. Two patients had a febrile episode without signs and symptoms of bacteremia. Subcostal access was used in all of the patients, and none of the patients had any complications. Based on our experience, we conclude that PNL is a safe and effective method in the management of pediatric stone disease.

  3. Hanford Site ground-water surveillance for 1989

    International Nuclear Information System (INIS)

    Evans, J.C.; Bryce, R.W.; Bates, D.J.; Kemner, M.L.

    1990-06-01

    This annual report of ground-water surveillance activities provides discussions and listings of results for ground-water monitoring at the Hanford Site during 1989. The Pacific Northwest Laboratory (PNL) assesses the impacts of Hanford operations on the environment for the US Department of Energy (DOE). The impact Hanford operations has on ground water is evaluated through the Hanford Site Ground-Water Surveillance program. Five hundred and sixty-seven wells were sampled during 1989 for Hanford ground-water monitoring activities. This report contains a listing of analytical results for calendar year (CY) 1989 for species of importance as potential contaminants. 30 refs., 29 figs,. 4 tabs

  4. Characterization of the first core sample of neutralized current acid waste from double-shell tank 101-AZ

    International Nuclear Information System (INIS)

    Peterson, M.E.; Scheele, R.D.; Tingey, J.M.

    1989-09-01

    In FY 1989, Westinghouse Hanford Company (WHC) successfully obtained four core samples (totaling seven segments) of neutralized current acid waste (NCAW) from double-shell tanks (DSTs) 101-AZ and 102-AZ. A segment was a 19-in.-long and 1-in.-diameter cylindrical sample of waste. A core sample consisted of enough 19-in.-long segments to obtain the waste of interest. Three core samples were obtained from DST 101-AZ and one core sample from DST 102-AZ. Two DST 101-AZ core samples consisted of two segments per core, and the third core sample consisted of only one segment. The third core consisted of the solids from the bottom of the tank and was used to determine the relative abrasiveness of this NCAW. The DST 102-AZ core sample consisted of two segments. The core samples were transported to the Pacific Northwest Laboratory (PNL), where the waste was extruded from its sampler and extensively characterized. A characterization plan was followed that simulated the processing of the NCAW samples through retrieval, pretreatment and vitrification process steps. Physical, rheological, chemical and radiochemical properties were measured throughout the process steps. The characterization of the first core sample from DST 101-AZ was completed, and the results are provided in this report. The results for the other core characterizations will be reported in future reports. 3 refs., 13 figs., 10 tabs

  5. Sediment and radionuclide transport in rivers. Phase 3. Field sampling program for Cattaraugus and Buttermilk Creeks, New York

    International Nuclear Information System (INIS)

    Ecker, R.M.; Walters, W.H.; Onishi, Y.

    1982-08-01

    A field sampling program was conducted on Cattaraugus and Buttermilk Creeks, New York during April 1979 to investigate the transport of radionuclides in surface waters as part of a continuing program to provide data for application and verification of Pacific Northwest Laboratory's (PNL) sediment and radionuclide transport model, SERATRA. Bed sediment, suspended sediment and water samples were collected during unsteady flow conditions over a 45 mile reach of stream channel. Radiological analysis of these samples included gamma ray spectrometry analysis, and radiochemical separation and analysis of Sr-90, Pu-238, Pu-239, 240, Am-241 and Cm-244. Tritium analysis was also performed on water samples. Based on the evaluation of radionuclide levels in Cattaraugus and Buttermilk Creeks, the Nuclear Fuel Services facility at West Valley, New York, may be the source of Cs-137, Sr-90, Cs-134, Co-60, Pu-238, Pu-239, 240, Am-241, Cm-244 and tritium found in the bed sediment, suspended sediment and water of Buttermilk and Cattaraugus Creeks. This field sampling effort was the last of a three phase program to collect hydrologic and radiologic data at different flow conditions

  6. Waste Tank Organic Safety Project: Analysis of liquid samples from Hanford waste tank 241-C-103

    International Nuclear Information System (INIS)

    Pool, K.H.; Bean, R.M.

    1994-03-01

    A suite of physical and chemical analyses has been performed in support of activities directed toward the resolution of an Unreviewed Safety Question concerning the potential for a floating organic layer in Hanford waste tank 241-C-103 to sustain a pool fire. The analysis program was the result of a Data Quality Objectives exercise conducted jointly with staff from Westinghouse Hanford Company and Pacific Northwest Laboratory (PNL). The organic layer has been analyzed for flash point, organic composition including volatile organics, inorganic anions and cations, radionuclides, and other physical and chemical parameters needed for a safety assessment leading to the resolution of the Unreviewed Safety Question. The aqueous layer underlying the floating organic material was also analyzed for inorganic, organic, and radionuclide composition, as well as other physical and chemical properties. This work was conducted to PNL Quality Assurance impact level III standards (Good Laboratory Practices)

  7. Our percutaneous nephrolitotomy experience in patients with horseshoe kidney

    Directory of Open Access Journals (Sweden)

    Tufan Suelozgen

    2015-07-01

    Full Text Available Objectives: Horseshoe kidney is the most common renal congenital fusion anomaly. Kidney stone formation is more common in horseshoe kidneys and some of them requires surgical procedure. So we want to evaluate the results of PNL in patients with horseshoe kidney anomaly. Matherial and method: Between January 2009-January 2014 PNL operation was performed in 6 patients with horseshoe kidney anomaly in our clinic. Success of surgery and postoperative/peroperative complications were evalutaed retrospectively. Results: No severe complications occured in any patient caused by surgery. Three patients became stonefree. One patient had less than 4 mm. residual stone, two patients had more than 4 mm. residual stone. Conclusion: PNL is safe surgical method and it can be performed successfully in patients with horseshoe kidney anomaly.

  8. Confirmation of the observation of 2νββ decay of 76Ge

    International Nuclear Information System (INIS)

    Avignone, F.T. III; Guerard, C.K.; Brodzinski, R.L.; Miley, H.S.; Reeves, J.H.; Kirpichnikov, I.V.; Starostin, A.S.; Pogosov, V.S.; Tamanyan, A.G.

    1991-01-01

    Two previous independent reports of 2v ββ decay by the ITEP-YPI Collaboration, T 1/2 2v =(9±1)x10 20 yr (1σ), and the PNL-USC Collaboration, T 1/2 2v =(1.12(+0.48-0.26)x10 21 yr (2σ), are confirmed. A 0.25 kg Ge(Li) detector, isotopically enriched to 85% in 76 Ge, was operated in the PNL-USC ultralow-background facility in the Homestake gold mine. Following a single correction to the data, a spectrum resembling that observed in the earlier PNL-USC experiment, with about the same intensity per 76 Ge atom per year, was observed. The measured half-life is T 1/2 2v =(9.2(+0.7-0.4)x10 20 yr (2σ). (orig.)

  9. Data validation report for the 100-FR-3 Operable Unit, third round groundwater samples

    International Nuclear Information System (INIS)

    Ayres, J.M.

    1994-01-01

    Westinghouse-Hanford has requested that a minimum of 20% of the total number of Sample Delivery Groups be validated for the 100-FR-3 operable Unit Third Round Groundwater sampling investigation. Therefore, the data from the chemical analysis of 51 samples from this sampling event and their related quality assurance samples were reviewed and validated to verify that reported sample results were of sufficient quality to support decisions regarding remedial actions performed at this site. The report is broken down into sections for each chemical analysis and radiochemical analysis type. Each section addresses the data package completeness, holding time adherence, instrument calibration and tuning acceptability, blank results, accuracy, precision, system performance, as well as the compound identification and quantitation. In addition, each section has an overall assessment and summary for the data packages reviewed for the particular chemical/radiochemical analyses. Detailed backup information is provided to the reader by SDG No. and sample number. For each data package, a matrix of chemical analyses per sample number is presented, as well as data qualification summaries

  10. Team interaction skills evaluation criteria for nuclear power plant control room operators

    International Nuclear Information System (INIS)

    Montgomery, J.C.; Hauth, J.T.

    1991-01-01

    Team interaction skills are an essential aspect of safe nuclear power plant control room operations. Previous research has shown that, when a group works together, rather than as individuals, more effective operations are possible. However, little research has addressed how such team interaction skills can be measured. In this study rating scales were developed specifically for such a measurement purpose. Dimensions of team skill performance were identified from previous research and experience in the area, incorporating the input of Pacific Northwest Laboratory (PNL) contract operator licensing examiners. Rating scales were developed on the basis of these dimensions, incorporating a modified Behaviorally Anchored Rating Scale (BARS) as well as Behavioral Frequency formats. After a pilot-testing/revision process, rating data were collected using 11 control room crews responding to simulator scenarios at a boiling water and a pressurized water reactor. Statistical analyses of the resulting data revealed moderate inter-rater reliability using the Behavioral Frequency scales, relatively low inter-rater reliability using the BARS, and moderate support for convergent and discriminant validity of the scales. It was concluded that the scales show promise psychometrically and in terms of user acceptability, but that additional scale revision is needed before field implementation. Recommendations for scale revision and directions for future research were presented

  11. Data validation report for the 100-HR-3 Operable Unit first quarter 1994 groundwater sampling data

    Energy Technology Data Exchange (ETDEWEB)

    Biggerstaff, R.L.

    1994-06-24

    Westinghouse-Hanford has requested that a minimum of 20% of the total number of Sample Delivery Groups be validated for the 100-HR-3 Operable Unit First Quarter 1994 Groundwater Sampling Investigation. Therefore, the data from the chemical analysis of twenty-four samples from this sampling event and their related quality assurance samples were reviewed and validated to verify that reported sample results were of sufficient quality to support decisions regarding remedial actions performed at this site. The samples were analyzed by Thermo-Analytic Laboratories (TMA) and Roy F. Weston Laboratories (WESTON) using US Environmental Protection Agency (EPA) CLP protocols. Sample analyses included: inorganics; and general chemical parameters. Forty-two samples were validated for radiochemical parameters by TMA and Teledyne.

  12. Data validation report for the 100-HR-3 Operable Unit first quarter 1994 groundwater sampling data

    International Nuclear Information System (INIS)

    Biggerstaff, R.L.

    1994-01-01

    Westinghouse-Hanford has requested that a minimum of 20% of the total number of Sample Delivery Groups be validated for the 100-HR-3 Operable Unit First Quarter 1994 Groundwater Sampling Investigation. Therefore, the data from the chemical analysis of twenty-four samples from this sampling event and their related quality assurance samples were reviewed and validated to verify that reported sample results were of sufficient quality to support decisions regarding remedial actions performed at this site. The samples were analyzed by Thermo-Analytic Laboratories (TMA) and Roy F. Weston Laboratories (WESTON) using US Environmental Protection Agency (EPA) CLP protocols. Sample analyses included: inorganics; and general chemical parameters. Forty-two samples were validated for radiochemical parameters by TMA and Teledyne

  13. The Effect of Percutaneous Nephrolithotomy Process on Hemodynamic, Electrolyte and Acid-Base Changes

    Directory of Open Access Journals (Sweden)

    Ercan Baş

    2015-10-01

    Full Text Available Aim: Operation of percutaneous nephrolithotomy (PNL, is the most commonly used method of renal stone surgery. During this operation, kidney must be continually irrigated with isotonic liquid. In our study, we investigated the volume of irrigation, irrigation duration, input the number of percutaneous renal parenchymal thickness and the degree of this finding the effects of on hemodynamic, electrolyte and metabolic changes. Method: 64 patient with an indication for percutaneous nephrolithotomy were included in the study. Before irrigation, during irrigation and the post- irrigation; pulse, systolic and diastolic blood pressure (bp, electrolytes, arterial blood gases were measured. In preoperative and postoperative 1. and 24. hours hemoglobin, creatinine levels were measured. Before the operation; pelvicaliectasis degree, parenchymal thickness, volume and duration of irrigation and the number of percutaneous entry were recorded in all patients. Results: Following the start of irrigation, changes in diastolic and systolic bp and pulse also not statistically significant. No significant change of partial oxygen, carbon dioxide, and oxygen saturation pressure was observed. After the operation, serum sodium, potassium, calcium values are within normal limits, but when compared with preoperative values the decrease of these values statistically significant were observed. Bicarbonate and ph values with irrigation period had a negative correlation. Although not clinically significant parenchymal thickness was found to be negative correlation with decrease of calcium. Additionally degrees of pelvicaliectasis has been found negative correlation with the decrease of sodium and bicarbonate. Conclusion: Hemodynamics and electrolytes did not change significantly both during and after the PNL process, but metabolic acidosis was observed towards the end of the PNL process. In long-term irrigation, repeated percutaneous entrances, people with moderate and severe

  14. Ultra-mini-percutaneous nephrolithotomy in pediatric nephrolithiasis: both low pressure and high efficiency.

    Science.gov (United States)

    Dede, Onur; Sancaktutar, Ahmet Ali; Dağguli, Mansur; Utangaç, Mazhar; Baş, Okan; Penbegul, Necmettin

    2015-10-01

    The management of urolithiasis in children differs from adults because of anatomic and metabolic abnormalities. At present, various minimally invasive and invasive treatment strategies have been recommended to treat urinary tract Stones, including shock wave lithotripsy (SWL), standard percutaneous nephrolithotomy (PNL), mini-PNL, retrograde intrarenal surgery (RIRS), micro-PNL, and a new technique termed ultra-mini PNL (UMP). UMP is a new method for the treatment of kidney stones. The main difference between UMP and standard PNL or mini-PNL lies in the small access sheath and in its design. A 9.5F pediatric compact cystoscope was used (Figure). A major advantage of UMP is that it provides similar stone-free rates when compared with standard PNL, with lower intrarenal pressure than micro-PNL. The aim of the study was to determine the applicability and safety of UMP in the treatment of pediatric kidney stones. We retrospectively reviewed the files of 39 kidney stones in children who had undergone UMP between May 2011 and October 2014. The indications for UMP included stones resistant to SWL, stones requiring repeated sessions of SWL, and stones size larger than 20 mm. The study included 17 females and 22 males, with a mean age of 5.8 ± 4.6 years. The mean hemoglobin loss was 0.9 ± 0.6 mg/dL and none of the patients required a blood transfusion. The complication rate of the PNL procedure was 15.3% (n = 6). Complete clearance was achieved in 32 patients (82%) with UMP monotherapy, which increased to 34% (87.1%) 4 weeks after the operation. Management of urolithiasis necessitates a balance between stone clearance and morbidity related to the procedure. SWL often leads to persistent residual stones. The developing RIRS can minimize the risks associated with bleeding and visceral injury, but sometimes the abnormal pelvicaliceal anatomy and poor imaging of the flexible ureteroscopy may impact its success rate and applications. It has been reported that PNL can be

  15. Developing and testing a vertical sintering furnace for remote nuclear applications

    International Nuclear Information System (INIS)

    Nesbitt, J.F.; Ryer, C.M.

    1980-01-01

    Horizontal-type furnaces used to sinter fuel pellets on a production basis are large and thus impractical for remote applications. However, research has shown that vertical-type furnaces are adaptable for use and are cheaper to operate and maintain. In 1979, Pacific Northwest Laboratory, working under the auspices of the Department of Energy's Fuel Refabrication and Development (FRAD) Program, began developing an advanced concept for a remotely operated furnace designed specifically to sinter nuclear fuel pellets. The FRAD Program at PNL ended before the sintering of nuclear fuels could be completely verified. However during 1979, PNL performed a sufficient number and variety of tests to establish that nuclear fuel pellets can be sintered in a vertical furnace

  16. Estimated routine radiation doses to transportation workers in alternative spent-fuel transportation systems

    International Nuclear Information System (INIS)

    Schneider, K.J.; Smith, R.I.; Daling, P.M.; Ross, W.A.; McNair, G.W.

    1988-01-01

    The federal system for the management of spent fuel and high-level radioactive waste includes the acceptance by the US Department of Energy (DOE) of the spent fuel or waste loaded in casks at the reactor or other waste generators, its transportation to a repository, and its handling and final emplacement in the repository. The DOE plans to implement a transportation system that is safe, secure, efficient, and cost-effective and will meet applicable regulatory safety and security requirements. The DOE commissioned the Pacific Northwest Laboratory (PNL) to develop estimates of the routine radiation doses that would result from the operation of a system postulated using current designs and practices. From that evaluation, PNL identified activities/operations that result in the higher fraction of doses, proposed conceptual alternatives that would effectively reduce such exposures, and evaluated the cost-effectiveness of such alternatives. The study is one of a series used in making overall system design and operational decisions in the development of the DOE's spent-fuel/high-level waste transportation system. This paper contains the highlights from the PNL study of the estimated radiation doses to the transportation workers in a postulated reference transportation system and potential alternatives to that system

  17. Sampling and analysis plan for remediation of Operable Unit 100-IU-3 waste site 600-104

    International Nuclear Information System (INIS)

    1997-08-01

    This sampling and analysis plan (SAP) presents the rationale and strategy for the sampling and analysis activities to support remediation of 100-IU-3 Operable Unit waste site 600-104. The purpose of the proposed sampling and analysis activities is to demonstrate that time-critical remediation of the waste site for soil containing 2,4-Dichlorophonoxyacetic acid salts and esters (2,4-D) and dioxin/furan isomers at concentrations that exceed cleanup levels has been effective. This shall be accomplished by sampling various locations of the waste site before and after remediation, analyzing the samples, and comparing the results to action levels set by the Washington State Department of Ecology

  18. Soil Gas Sampling Operating Procedure

    Science.gov (United States)

    EPA Region 4 Science and Ecosystem Support Division (SESD) document that describes general and specific procedures, methods, and considerations when collecting soil gas samples for field screening or laboratory analysis.

  19. FPFPspace2: A code for following airborne fission products in generic nuclear plant flow paths

    International Nuclear Information System (INIS)

    Owcarski, P.C.; Burk, K.W.; Ramsdell, J.V.; Yasuda, D.D.

    1991-03-01

    In order to assure that a nuclear power plant control room remains habitable during certain types of postulated accidents, Pacific Northwest Laboratory (PNL) has undertaken a special study for the US Nuclear Regulatory Commission. This purpose of this study is to develop software that can aid in the analyses of control room habitability during accidents in which airborne fission products could challenge internal air pathways to the control room. PNL has completed an initial version (FPFP) and final version (FPFP 2) of a software package that can estimate the unsteady-state invasion of quantities of fission products into the control room or any other destination within the nuclear plant via generic internal flow paths. This report consists of three parts: Section 2.0, Technical Bases, describes the flow path components and mechanisms of natural fission product deposition; Section 3.0, FPFP 2 Code Description, describes code organization and the functions of the subroutines; and Section 4.0, Code Operation, discusses details of input requirements, code output, and a sample case demonstration. The appendices consist of an FPFP 2 Fortran code listing, a listing of a code for building input files, forms for building input files, and the sample case input and output files. 7 refs., 3 figs

  20. Data validation summary report for the 100-BC-5 Operable Unit Round 9 Groundwater Sampling. Revision 0

    International Nuclear Information System (INIS)

    Kearney, A.T.

    1996-03-01

    The information provided in this validation summary report includes chemical analyses of samples from 100-BC-5 Operable Unit Round 9 Groundwater sampling data. Data from this sampling event and their related quality assurance (QA) samples were reviewed and validated in accordance with Westinghouse Hanford Company (WHC) guidelines at the requested level. Sample analyses included metals, general chemistry, and radiochemistry. Sixty metals samples were analyzed by Quanterra Environmental Services (QES) and Lockheed Analytical Services (LAS). The metals samples were validated using WHC protocols specified in Data Validation Procedures for Chemical Analyses. All qualifiers assigned to the metals data were based on this guidance. The Table 1.1 lists the metals sample delivery group (SDG) that were validated for this sampling event

  1. Sediment and radionuclide transport in rivers. Summary report, field sampling program for Cattaraugus and Buttermilk Creeks, New York

    International Nuclear Information System (INIS)

    Walters, W.H.; Ecker, R.M.; Onishi, Y.

    1982-11-01

    A three-phase field sampling program was conducted on the Buttermilk-Cattaraugus Creek system to investigate the transport of radionuclides in surface waters as part of a continuing program to provide data for application and verification of Pacific Northwest Laboratory's (PNL) sediment and radionuclide transport model, SERATRA. Phase 1 of the sampling program was conducted during November and December 1977; Phase 2 during September 1978; and Phase 3 during April 1979. Bed sediment, suspended sediment, and water samples were collected over a 45-mile reach of the creek system. Bed sediment samples were also collected at the mouth of Cattaraugus Creek in Lake Erie. A fourth sampling trip was conducted during May 1980 to obtain supplementary channel geometry data and flood plain sediment samples. Radiological analysis of these samples included gamma ray spectrometry analysis, and radiochemical separation and analysis of Sr-90, Pu-238, Pu-239,240, Am-241 and Cm-244. Tritium analysis was also performed on water samples. Based on the evaluation of radionuclide levels in Cattaraugus and Buttermilk Creeks, the Nuclear Fuel Services facility at West Valley, New York, may be the source of Cs-137, Sr-90, CS-134, Co-60, Pu-238, Pu-239,240, Am-241, Cm-244 and tritium found in the bed sediment, suspended sediment and water of Buttermilk and Cattaraugus Creeks

  2. Dynamic Sampling of Trace Contaminants During the Mission Operations Test of the Deep Space Habitat

    Science.gov (United States)

    Monje, Oscar; Valling, Simo; Cornish, Jim

    2013-01-01

    The atmospheric composition inside spacecraft during long duration space missions is dynamic due to changes in the living and working environment of crew members, crew metabolism and payload operations. A portable FTIR gas analyzer was used to monitor the atmospheric composition within the Deep Space Habitat (DSH) during the Mission Operations Test (MOT) conducted at the Johnson Space Center (JSC). The FTIR monitored up to 20 gases in near- real time. The procedures developed for operating the FTIR were successful and data was collected with the FTIR at 5 minute intervals. Not all the 20 gases sampled were detected in all the modules and it was possible to measure dynamic changes in trace contaminant concentrations that were related to crew activities involving exercise and meal preparation.

  3. Mini-percutaneous nephrolithotomy for stones in anomalous-kidneys: a prospective study.

    Science.gov (United States)

    Khadgi, Sanjay; Shrestha, Babu; Ibrahim, Hamdy; Shrestha, Sunil; ElSheemy, Mohammed S; Al-Kandari, Ahmed M

    2017-08-01

    To evaluate safety and efficacy of minipercutaneous nephrolithotomy (Mini-PNL) in management of stones in different types of renal anomalies. Patients with stones ≥2 cm or SWL-resistant stones in anomalous-kidneys treated by Mini-PNL between March 2010 and September 2012 were included prospectively. Mini-PNL was done under regional anesthesia in prone position with fluoroscopic guidance through 18 Fr sheath using semirigid ureteroscope (8.5/11.5 Fr) and pneumatic lithotripter. All patients were followed-up for 2-3 years. Stone-free rate was defined as absence of residual fragments ≥2 mm. Student-T, Mann-Whitney, Chi square (χ 2 ), Fisher-exact, one way ANOVA or Kruskal-Wallis test were used for analysis. Mini-PNL was performed for 59 patients (20 horseshoe, 15 malrotated, 7 polycystic, 13 duplex and 4 ectopic pelvic-kidneys). Mean age was 40.18 ± 12.75 (14-78) years. Mean stone burden was 31.72 ± 21.43 (7.85-141.3) mm 2 . Two tracts were required in 7 (11.9 %) patients. Tubeless Mini-PNL with double-J insertion was performed in all patients except two. Operative time was 50.17 ± 18.73 (15-105) min. Hemoglobin loss was 0.44 ± 0.30 (0-1.4) g/dL. Complications were reported in 15 (25.4 %) patients. No pleural injury, sepsis, perinephric-collection or renal-pelvis perforation were reported. Stone-free rate was 89.8 % (converted to open-surgery in one patient, second-look PNL in two patients, auxiliary SWL in three patients). Stone-free rate improved to 98.3 % after retreatment and auxiliary SWL. Site of puncture was mostly upper calyceal in horseshoe-kidney (80 %), mid calyceal in polycystic-kidney (85.7 %) and lower calyceal in duplex-kidney (46.2 %). Punctures were also significantly infracostal in horseshoe-kidney (100 %) and supracostal in both duplex (53.8 %) and malrotated-kidneys (66.7 %). Mini-PNL is safe for management of stones in anomalous-kidney with SFR comparable to standard-PNL but with less complications.

  4. Peer review of the Barselina Level 1 probabilistic safety assessment of the Ignalina Nuclear Power Plant, Unit 2

    International Nuclear Information System (INIS)

    McKay, S.L.; Coles, G.A.

    1995-01-01

    The Barselina Project is a Swedish-funded, cooperative effort among Lithuania, Russia and Sweden to transfer Western probabilistic safety assessment (PSA) methodology to the designers/operators of Ignalina Nuclear Power Plant (INPP). The overall goal is to use the PSA as a tool for assessing plant operational safety. The INPP is a two-unit, Former Soviet Union-designed nuclear facility located in Lithuania. The results of this PSA will ultimately be used to identify plant-specific improvements in system design and the conduct of facility operations, allowing improved operational safety. Pacific Northwest Laboratory (PNL) was asked to perform an independent expert peer review of the Barselina PSA. This report documents the findings of this review. This review, financed with nuclear safety assistance funds through the US Agency for International Development (USAID) and the US Department of Energy (DOE), satisfies Task II of the PNL peer review of the Barselina project. The objective is to provide an independent, in-proce ss examination of the Barselina Level 1 PSA of Ignalina Nuclear Power Plant, Unit 2. The review consisted of an investigation of the project documentation, interviews, and extensive discussions with the PSA staff during critical stages of the project. PNL assessed the readability, completeness, consistency, validity, and applicability of the PSA. The major aspects explored were its purpose, major assumptions, analysis/modeling, results, and interpretation. It was not within the scope of this review to perform plant walkdowns or to review material other than the PSA documentation

  5. Image Quality Modeling and Characterization of Nyquist Sampled Framing Systems with Operational Considerations for Remote Sensing

    Science.gov (United States)

    Garma, Rey Jan D.

    The trade between detector and optics performance is often conveyed through the Q metric, which is defined as the ratio of detector sampling frequency and optical cutoff frequency. Historically sensors have operated at Q ≈ 1, which introduces aliasing but increases the system modulation transfer function (MTF) and signal-to-noise ratio (SNR). Though mathematically suboptimal, such designs have been operationally ideal when considering system parameters such as pointing stability and detector performance. Substantial advances in read noise and quantum efficiency of modern detectors may compensate for the negative aspects associated with balancing detector/optics performance, presenting an opportunity to revisit the potential for implementing Nyquist-sampled (Q ≈ 2) sensors. A digital image chain simulation is developed and validated against a laboratory testbed using objective and subjective assessments. Objective assessments are accomplished by comparison of the modeled MTF and measurements from slant-edge photographs. Subjective assessments are carried out by performing a psychophysical study where subjects are asked to rate simulation and testbed imagery against a DeltaNIIRS scale with the aid of a marker set. Using the validated model, additional test cases are simulated to study the effects of increased detector sampling on image quality with operational considerations. First, a factorial experiment using Q-sampling, pointing stability, integration time, and detector performance is conducted to measure the main effects and interactions of each on the response variable, DeltaNIIRS. To assess the fidelity of current models, variants of the General Image Quality Equation (GIQE) are evaluated against subject-provided ratings and two modified GIQE versions are proposed. Finally, using the validated simulation and modified IQE, trades are conducted to ascertain the feasibility of implementing Q ≈ 2 designs in future systems.

  6. Nuclear waste glass melter: an update of technical progress

    International Nuclear Information System (INIS)

    Brouns, R.A.; Hanson, M.S.

    1984-08-01

    The direct slurry-fed ceramic-lined melter is currently the reference US process for treating defense and civilian high-level liquid waste. Extensive nonradioactive pilot-scale testing at Pacific Northwest Laboratory (PNL) and Savannah River Laboratory has proven the process, defined operating parameters, and identified successful equipment design concepts. Programs at PNL continue to support several of the planned US vitrification plants through preparation of equipment designs and flowsheet testing. Current emphasis is on remotization of equipment, radioactive verification testing, and resolution of remaining technical issues. Development of this technology, technical status, and planned development activities are discussed. 9 references, 4 figures

  7. Ecological investigations at the Pantex Plant Site, 1992

    International Nuclear Information System (INIS)

    Cushing, C.E.; Mazaika, R.R.; Phillips, R.C.

    1993-09-01

    In 1992, Pantex requested that Pacific Northwest Laboratory (PNL) conduct a series of ecological surveys to provide baseline information for designing detailed ecological studies on the various ecosystems present at the Pantex plant site near Amarillo, Texas. To this end, PNL scientist and technicians visited the site at different times to conduct investigations and collect samples: July 6--13: birds, small mammals, general habitat assessment; August 10--14: wetland vegetation, birds, small mammals, Playa invertebrates; and September 7--11: birds, small mammals. This report presents the results of these three surveys

  8. Fiber optics frequency comb enabled linear optical sampling with operation wavelength range extension.

    Science.gov (United States)

    Liao, Ruolin; Wu, Zhichao; Fu, Songnian; Zhu, Shengnan; Yu, Zhe; Tang, Ming; Liu, Deming

    2018-02-01

    Although the linear optical sampling (LOS) technique is powerful enough to characterize various advanced modulation formats with high symbol rates, the central wavelength of a pulsed local oscillator (LO) needs to be carefully set according to that of the signal under test, due to the coherent mixing operation. Here, we experimentally demonstrate wideband LOS enabled by a fiber optics frequency comb (FOFC). Meanwhile, when the broadband FOFC acts as the pulsed LO, we propose a scheme to mitigate the enhanced sampling error arising in the non-ideal response of a balanced photodetector. Finally, precise characterizations of arbitrary 128 Gbps PDM-QPSK wavelength channels from 1550 to 1570 nm are successfully achieved, when a 101.3 MHz frequency spaced comb with a 3 dB spectral power ripple of 20 nm is used.

  9. Comparison of retrograde intrarenal surgery, shockwave lithotripsy, and percutaneous nephrolithotomy for treatment of medium-sized radiolucent renal stones.

    Science.gov (United States)

    Resorlu, Berkan; Unsal, Ali; Ziypak, Tevfik; Diri, Akif; Atis, Gokhan; Guven, Selcuk; Sancaktutar, Ahmet Ali; Tepeler, Abdulkadir; Bozkurt, Omer Faruk; Oztuna, Derya

    2013-12-01

    To compare the outcomes of shock wave lithotripsy (SWL), percutaneous nephrolithotomy (PNL), and retrograde intrarenal surgery (RIRS) for 10-20 mm radiolucent renal calculi by evaluating stone-free rates and associated complications. A total of 437 patients at 7 institutions who underwent SWL (n = 251), PNL (n = 140), or RIRS (n = 46) were enrolled in our study. Clinical success was defined as stone-free status or asymptomatic insignificant residual fragments PNL, and RIRS (p PNL and RIRS (21.9 vs 5.7 vs 8.7%, respectively; p PNL, and RIRS were 7.6, 22.1, and 10.9%, respectively (p PNL group received blood transfusions, while none of the patients in RIRS and SWL groups transfused. Hospitalization time per patient was 1.3 ± 0.5 days in the RIRS group, while it was 2.6 ± 0.9 days in the PNL group (p PNL group compared to RIRS (145.7 ± 101.7 vs 28.7 ± 18.7 s, and 57.5 ± 22.1 vs 43.1 ± 17 min, respectively). For treatment of moderate-sized radiolucent renal stones, RIRS and PNL provide significantly higher success and lower retreatment rate compared with SWL. Although PNL is effective, its biggest drawback is its invasiveness. Blood loss, radiation exposure, hospital stay, and morbidities of PNL can be significantly reduced with RIRS technique.

  10. ANL small-sample calorimeter system design and operation

    International Nuclear Information System (INIS)

    Roche, C.T.; Perry, R.B.; Lewis, R.N.; Jung, E.A.; Haumann, J.R.

    1978-07-01

    The Small-Sample Calorimetric System is a portable instrument designed to measure the thermal power produced by radioactive decay of plutonium-containing fuels. The small-sample calorimeter is capable of measuring samples producing power up to 32 milliwatts at a rate of one sample every 20 min. The instrument is contained in two packages: a data-acquisition module consisting of a microprocessor with an 8K-byte nonvolatile memory, and a measurement module consisting of the calorimeter and a sample preheater. The total weight of the system is 18 kg

  11. Sampling and analysis plan for remediation of Operable Unit 100-IU-3 waste site 600-104. Revision 1

    International Nuclear Information System (INIS)

    1997-08-01

    This sampling and analysis plan presents the rationale and strategy for the sampling and analysis activities to support remediation of 100-IU-3 Operable Unit waste site 600-104. The purpose of the proposed sampling and analysis activities is to demonstrate that time-critical remediation of the waste site for soil containing 2,4-Dichlorophenoxyacetic acid salts and esters (2,4-D) and dioxin/furan isomers at concentrations that exceed cleanup levels has been effective. This shall be accomplished by sampling various locations of the waste site before and after remediation, analyzing the samples, and comparing the results to action levels set by the Washington State Department of Ecology

  12. Air sampling methods to evaluate microbial contamination in operating theatres: results of a comparative study in an orthopaedics department.

    Science.gov (United States)

    Napoli, C; Tafuri, S; Montenegro, L; Cassano, M; Notarnicola, A; Lattarulo, S; Montagna, M T; Moretti, B

    2012-02-01

    To evaluate the level of microbial contamination of air in operating theatres using active [i.e. surface air system (SAS)] and passive [i.e. index of microbial air contamination (IMA) and nitrocellulose membranes positioned near the wound] sampling systems. Sampling was performed between January 2010 and January 2011 in the operating theatre of the orthopaedics department in a university hospital in Southern Italy. During surgery, the mean bacterial loads recorded were 2232.9 colony-forming units (cfu)/m(2)/h with the IMA method, 123.2 cfu/m(3) with the SAS method and 2768.2 cfu/m(2)/h with the nitrocellulose membranes. Correlation was found between the results of the three methods. Staphylococcus aureus was detected in 12 of 60 operations (20%) with the membranes, five (8.3%) operations with the SAS method, and three operations (5%) with the IMA method. Use of nitrocellulose membranes placed near a wound is a valid method for measuring the microbial contamination of air. This method was more sensitive than the IMA method and was not subject to any calibration bias, unlike active air monitoring systems. Copyright © 2011 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  13. [Solitary stones of the lower renal calyx: how to treat?

    Science.gov (United States)

    Martov, A G; Ergakov, D V; Andronov, A S; Dutov, S V; Takhaev, R A; Kil'chukov, Z I; Moskalenko, S A

    2017-06-01

    The choice of treatment for the stones of the lower renal calyx is one of the challenging issues of modern urology. The aim of this retrospective and prospective study was to investigate the clinical effectiveness and safety of 3 modern minimally invasive techniques for treating renal stones: percutaneous (PNL) and transurethral (TNL) nephrolithotripsy and extracorporeal shock wave lithotripsy (ESWL) in patients with solitary lower calyx stones sized from 10 to 15 mm. The study included 136 patients with symptomatic stones of the lower calyces, who underwent ESWL, PNL and TNL from November 2010 to the present day. The criteria for inclusion in the study were: the presence of a solitary stone of the lower calyx, the stone size of 10 mm to 15 mm, the performance of the classical (standard) PNL in the prone position (puncture access 28-30 Fr) and the follow-up examination at 3 months after the operation. Forty-six patients underwent ESWL, 49 - PNL, and 41 - TNL. Postoperative follow-up was done at 3 months and included a plain radiography, ultrasound and non-contrast-enhanced computed tomography. The stone free rate (SFR) was used as a criterion for the effectiveness of the intervention, where the stone size of 3 mm was taken as the upper limit for the possible presence of fragments. Besides, the rate of repeat interventions, complications and subjective assessment of patients treatment satisfaction (0 to 10) by using visual analogue scale (VAS) were investigated. The effectiveness analysis of the three methods for treating the lower calyx stones sized 10-15 mm showed that PNL was no more effective than TNL (SFR 95.9% and 85.4%, respectively), but both methods were significantly more effective than ESWL (SFR 69.5%). 29.3% of patients who underwent TNL required repeat interventions (TNL or ESWL), while among those treated with ESWL, 45.6% required repeat ESWL sessions. PNL resulted in stone clearance in one stage. Postoperative inflammatory complications were most

  14. [Analysis of development, safety and efficacy of percutaneous nephrolithotomy for management of upper urinary tract calculi in pediatric patients].

    Science.gov (United States)

    Yu, L P; Xu, T

    2017-08-18

    To evaluate the development, safety and efficacy of percutaneous nephrolithotomy(PNL) for management of upper urinary tract calculi in pediatric patients. In the study, 77 pediatric patients undergoing 87 PNLs through mini or standard tract for upper urinary tract calculi between January 2005 and December 2016 in Peking University People's hospital were reviewed, including 69 renal calculi, 6 upper ureteral calculi, 12 renal and upper ureteral calculi, 35 single calculi, 43 multiple calculi and 9 staghorn calculi. The development and efficacy of PNL in pediatric patients were studied by analyzing the characteristics and clinical indexes, and by reviewing the associated literature. The Clavien classification system was used to evaluate the complications after PNL. A total of 87 PNLs were performed in 77 pediatric patients. Eighty-one upper urinary tract calculi were managed through a single tract(93.1%), 5 pediatric patients were managed through 2 tracts(5.7%), and 1 pediatric patient was managed through 3 tracts(1.2%). The mean operating time was (77.0±29.8) min. The stone-free rate after one session was 100% for single calculi and 71.2% for multiple or staghorn calculi, 5(5.8%) children underwent auxiliary procedure to remove the residual calculi and the final stone-free rate of PNL was 88.5%. One of the main complications of pediatric PNL was fever. Sixteen (18.4%) had moderate fever(38-39 °C), 5 (5.7%) had high fever (39-40 °C) and there were no severe complications of infection, such as sepsis or septic shock. The mean hemoglobin loss was (10.3±16.1) g/L and the serum creatinine rise was (7.0±13.3) μmol/L. One(1.2%) pediatric patient suffered ureteroscopic lithotripsy because of the obstruction by the residual stone in ureter. No injury of organs or retroperitoneal urinary extravasation occurred. General assessment of the complications showed Clavien grade I complications in 14 (16.1%) pediatric patients, grade II in 7(8.0%) children and grade III in 1

  15. RECOMMENDED OPERATING PROCEDURE NO. 56: COLLECTION OF GASEOUS GRAB SAMPLES FROM COMBUSTION SOURCES FOR NITROUS OXIDE MEASUREMENT

    Science.gov (United States)

    The document is a recommended operating procedure, prepare or use in research activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). The procedure applies to the collection of gaseous grab samples from fossil fuel combustion sources for subsequent a...

  16. Field Sampling Plan for the Operable Units 6-05 and 10-04 Remedial Action, Phase IV

    Energy Technology Data Exchange (ETDEWEB)

    R. Wells

    2006-11-14

    This Field Sampling Plan outlines the collection and analysis of samples in support of Phase IV of the Waste Area Group 10, Operable Units 6-05 and 10-04 remedial action. Phase IV addresses the remedial actions to areas with the potential for unexploded ordnance at the Idaho National Laboratory Site. These areas include portions of the Naval Proving Ground, the Arco High-Altitude Bombing Range, and the Twin Buttes Bombing Range. The remedial action consists of removal and disposal of ordnance by high-order detonation, followed by sampling to determine the extent, if any, of soil that might have been contaminated by the detonation activities associated with the disposal of ordnance during the Phase IV activities and explosives during the Phase II activities.

  17. Validation of Scales from the Deployment Risk and Resilience Inventory in a Sample of Operation Iraqi Freedom Veterans

    National Research Council Canada - National Science Library

    Vogt, D. S; Proctor, S. P; King, D. W; King, L. A; Vasterling, J. J

    2008-01-01

    .... Although initial evidence for the reliability and validity of DRRI scales based on Gulf War veteran samples is encouraging, evidence with respect to a more contemporary cohort of Operation Iraqi Freedom (OIF...

  18. Differential diagnosis of primary nasopharyngeal lymphoma and nasopharyngeal carcinoma focusing on CT, MRI, and PET/CT.

    Science.gov (United States)

    Cho, Kyu-Sup; Kang, Dae-Woon; Kim, Hak-Jin; Lee, Jong-Kil; Roh, Hwan-Jung

    2012-04-01

    No study has done a comparative analysis of radiologic imaging findings between primary nasopharyngeal lymphoma (PNL) and nasopharyngeal carcinoma (NPC). The purpose of this study was to analyze computed tomography (CT) and magnetic resonance (MR) images and to evaluate the maximum standardized uptake value (SUV max) of positron emission tomography (PET)/CT between PNL and NPC, knowing the imaging features that distinguish PNL from NPC. Cross-sectional study. University tertiary care facility. The authors analyzed the features on CT, MR imaging, and PET/CT of 16 patients diagnosed with PNL and 32 patients diagnosed with NPC histopathologically. Patients with PNL had a larger tumor volume and showed symmetry of tumor shape than did patients with NPC. Patients with PNL also had higher tumor homogeneity than NPC patients on CT, T2-weighted, and postcontrast MR images. All PNL patients showed a high degree of enhancement without invasion to the adjacent deep structure. The involvement of the Waldeyer ring was significantly higher in PNL patients. Cervical and retropharyngeal lymphadenopathy and PET/CT SUV max showed no significant difference between PNL and NPC. If the images present a bulky, symmetric nasopharyngeal mass with marked homogeneity, a high degree of enhancement, and a higher Waldeyer ring involvement combined with no invasion into the deep structure, PNL should be considered over NPC.

  19. Biliary peritonitis due to gall bladder perforation after percutaneous nephrolithotomy

    Directory of Open Access Journals (Sweden)

    Nikhil Ranjan

    2015-01-01

    Full Text Available A 19-year-old male patient underwent right percutaneous nephrolithotomy (PNL for right renal 1.5 × 1.5 cm lower pole stone. The procedure was completed uneventfully with complete stone clearance. The patient developed peritonitis and shock 48 h after the procedure. Exploratory laparotomy revealed a large amount of bile in the abdomen along with three small perforations in the gall bladder (GB and one perforation in the caudate lobe of the liver. Retrograde cholecystectomy was performed but the patient did not recover and expired post-operatively. This case exemplifies the high mortality of GB perforation after PNL and the lack of early clinical signs.

  20. Analisa Beban Kerja Fisik dan Mental dengan Menggunakan Work Sampling dan NASA-TLX Untuk Menentukan Jumlah Operator

    Directory of Open Access Journals (Sweden)

    Anton Maretno

    2015-04-01

    Full Text Available Perbedaan sistem kerja yang ada di antara operator Quality Control dan operator produksi pada divisi Particle Board menyebabkan adanya perbedaan nilai beban kerja. Hal tersebut dapat dilihat dari perbedaan jumlah jam lembur pada kedua bagian tersebut dimana jumlah jam lembur pada operator Quality Control lebih besar. Penelitian ini bertujuan untuk menganalisa beban kerja operator Quality Control serta menganalisa jumlah operator yang optimal untuk menyelesaikan pekerjaan Quality Control.Penelitian ini menggunakan metode pengukuran beban kerja fisik (Work sampling dan pengukuran beban kerja Mental NASA - Task Load Index (NASA-TLX. Menurut perhitungan beban kerja fisik dan mental, pelaksana yang memiliki load paling tinggi adalah pekerjaanQuality Control ( QC Finish board (108.1%, sedangkan terendah ada pada pekerjaan Quality Control ( QC Produk (72.3%. Setelah penambahan pelaksana  Quality Control ( QC Finish board sebanyak 1 orang, beban kerja fisik untuk pekerjaanQuality Control ( QC Finish board menjadi 71.1%. Sedangkan untuk pekerjaan Quality Control yang lain tidak membutuhkan tambahan operator karena bisa memanfaatkan waktu idle yang dimiliki pelaksana Quality Control ( QC Produk untuk membantu pekerjaan lain

  1. Thermal ramp rate effects on mixed-oxide fuel swelling/gas release

    International Nuclear Information System (INIS)

    Hinman, C.A.; Randklev, E.H.

    1979-01-01

    Macroscopic swelling behavior of PNL-10 was compared to that of PNL-2 fuel and it was found that the swelling-threshold behavior is similar for similar thermal conditions. Transient fission gas release for the PNL-10 fuel is very similar to that observed for the PNL-2 fuel for similar thermal conditions

  2. Lithotrites and postoperative fever

    DEFF Research Database (Denmark)

    Chu, David I; Lipkin, Michael E; Wang, Agnes J

    2013-01-01

    OBJECTIVE: To compare the risks of fever from different lithotrites after percutaneous nephrolithotomy (PNL). MATERIALS AND METHODS: The Clinical Research Office of the Endourological Society (CROES) PNL database is a prospective, multi-institutional, international PNL registry. Of 5,803 total...... with fever [Odds Ratio (OR) 1.17, p = 0.413], while diabetes (OR 1.32, p = 0.048), positive urine culture (OR 2.08, p PNL...... fever was not significantly different among the various lithotrites used in the CROES PNL study....

  3. Combined use of flexible ureteroscopic lithotripsy with micro-percutaneous nephrolithotomy in pediatric multiple kidney stones.

    Science.gov (United States)

    Li, Jun; Wang, Wenying; Du, Yuan; Tian, Ye

    2018-03-28

    We investigated the clinical value of treating pediatric multiple kidney stones with extensive distribution using flexible ureteroscopic lithotripsy (FUL) combined with micro-percutaneous nephrolithotomy (micro-PNL). In total, 21 pediatric patients with multiple renal calculi between May 2016 and June 2017 received FUL combined with micro-PNL. The group included 13 boys and eight girls; the patients' mean age was 3.8 years (range 1-8 years). The maximum stone diameter ranged from 1.0 to 1.5 cm. FUL was first performed in the lithotomy position to fragment stones that were located in the renal pelvis, and upper and mid-renal calyx. Patients were then moved to a prone position, and micro-PNL was performed to treat lower pole stones that could not be reached by the flexible ureteroscope during FUL. Percutaneous renal access to the lower calyx was achieved using a 4.8F "all-seeing needle" with ultrasound guidance, and stone fragmentation was performed with a 200-μm holmium laser at different settings to disintegrate 1- to 2-mm fragments. All 21 pediatric patients with multiple kidney stones underwent combined FUL and micro-PNL. The stone free rate (SFR) was 85.7% (18/21). The mean surgical time was 45 min (range 30-70 min). The mean volume of irrigation fluid used was 480 mL (range 300-1200 mL). The mean surgical time for FUL and micro-PNL was 31 min and 14 min, respectively, and the mean volume of fluid used for FUL and micro-PNL was 360 mL and 120 mL, respectively. According to the modified Clavien classification, grade 1 and 2 postoperative complications occurred in five and one patients, respectively. The mean decrease in the level of hemoglobin was 0.4 g/dL (0-0.7 g/dL), and no patients required a transfusion. The average hospital stay was 3 days (range 2-5 days). Combined FUL and micro-PNL is a safe, effective, and minimally invasive operation to remove multiple renal calculi with extensive distribution in children in selected cases. Copyright © 2018

  4. Dynamical sampling and frame representations with bounded operators

    DEFF Research Database (Denmark)

    Christensen, Ole; Hasannasab, Marzieh; Rashidi, Ehsan

    2017-01-01

    The purpose of this paper is to study frames for a Hilbert space H, having the form {Tnφ}n=0∞ for some φ∈H and an operator T:H→H. We characterize the frames that have such a representation for a bounded operator T, and discuss the properties of this operator. In particular, we prove that the image...... chain of T has finite length N in the overcomplete case; furthermore {Tnφ}n=0∞ has the very particular property that {Tnφ}n=0N−1∪{Tnφ}n=N+ℓ∞ is a frame for H for all ℓ∈N0. We also prove that frames of the form {Tnφ}n=0∞ are sensitive to the ordering of the elements and to norm...

  5. Molecular cloning and characterization of an Erwinia carotovora subsp. carotovora pectin lyase gene that responds to DNA-damaging agents.

    OpenAIRE

    McEvoy, J L; Murata, H; Chatterjee, A K

    1990-01-01

    recA-mediated production of pectin lyase (PNL) and the bacteriocin carotovoricin occurs in Erwinia carotovora subsp. carotovora 71 when this organism is subjected to agents that damage or inhibit the synthesis of DNA. The structural gene pnlA was isolated from a strain 71 cosmid gene library following mobilization of the cosmids into a moderate PNL producer, strain 193. The cosmid complemented pnl::Tn5 but not ctv::Tn5 mutations. A constitutive level of PNL activity was detected in RecA+ and ...

  6. An acidic pectin lyase from Aspergillus niger with favourable efficiency in fruit juice clarification.

    Science.gov (United States)

    Xu, S X; Qin, X; Liu, B; Zhang, D Q; Zhang, W; Wu, K; Zhang, Y H

    2015-02-01

    The pectin lyase gene pnl-zj5a from Aspergillus niger ZJ5 was identified and expressed in Pichia pastoris. PNL-ZJ5A was purified by ultrafiltration, anion exchange and gel chromatography. The Km and Vmax values determined using citrus pectin were 0.66 mg ml(-1) and 32.6 μmol min(-1) mg(-1) , respectively. PNL-ZJ5A exhibited optimal activity at 43°C and retained activity over 25-50°C. PNL-ZJ5A was optimally active at pH 5 and effective in apple juice clarification. Compared with controls, PNL-ZJ5A increased the fruit juice yield significantly. Furthermore, PNL-ZJ5A reduced the viscosity of apple juice by 38.8% and increased its transmittance by 86.3%. PNL-ZJ5A combined with a commercial pectin esterase resulted in higher juice volume. © 2014 The Society for Applied Microbiology.

  7. Outcome from 5-year live surgical demonstrations in urinary stone treatment: are outcomes compromised?

    NARCIS (Netherlands)

    Legemate, Jaap D.; Zanetti, Stefano P.; Baard, Joyce; Kamphuis, Guido M.; Montanari, Emanuele; Traxer, Olivier; de la Rosette, Jean Jmch

    2017-01-01

    To compare intra- and post-operative outcomes of endourological live surgical demonstrations (LSDs) and routine surgical practice (RSP) for urinary stones. Consecutive ureterorenoscopic (URS) and percutaneous (PNL) urinary stone procedures over a 5-year period were reviewed. Procedures were divided

  8. MESOILT2, a Lagrangian trajectory climatological dispersion model

    International Nuclear Information System (INIS)

    Ramsdell, J.V. Jr.; Burk, K.W.

    1991-03-01

    The objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation dose that individuals could have received as a result of emissions from nuclear operations at the Hanford Site. An independent Technical Steering Panel (TSP) directs the project, which is conducted by the Pacific Northwest Laboratory (PNL). The TSP directed PNL to demonstrate that its recommended approach for dose reconstruction is technically feasible and practical. This demonstration was Phase 1 of the project. This report is specifically concerned with the approach that PNL recommends for dealing with the atmospheric pathway. The TSP established a model domain for the atmospheric pathway for Phase 1 that includes 10 counties in Washington and Oregon and covers several thousand square miles. It is unrealistic to assume that atmospheric models which estimate transport and diffusion based on the meteorological conditions near the point of release of material at the time of release are adequate for a region this large. As a result, PNL recommended use of a Lagrangian trajectory, puff dispersion model for the Phase I study. This report describes the MESOILT2 computer code and the atmospheric transport, diffusion, deposition, and depletion models used in Phase I. The contents of the report include a technical description of the models, a user's guide for the codes, and descriptions of the individual code elements. 53 refs., 17 figs., 5 tabs

  9. Technology, safety and costs of decommissioning a reference boiling water reactor power station: Comparison of two decommissioning cost estimates developed for the same commercial nuclear reactor power station

    International Nuclear Information System (INIS)

    Konzek, G.J.; Smith, R.I.

    1990-12-01

    This study presents the results of a comparison of a previous decommissioning cost study by Pacific Northwest Laboratory (PNL) and a recent decommissioning cost study of TLG Engineering, Inc., for the same commercial nuclear power reactor station. The purpose of this comparative analysis on the same plant is to determine the reasons why subsequent estimates for similar plants by others were significantly higher in cost and external occupational radiation exposure (ORE) than the PNL study. The primary purpose of the original study by PNL (NUREG/CR-0672) was to provide information on the available technology, the safety considerations, and the probable costs and ORE for the decommissioning of a large boiling water reactor (BWR) power station at the end of its operating life. This information was intended for use as background data and bases in the modification of existing regulations and in the development of new regulations pertaining to decommissioning activities. It was also intended for use by utilities in planning for the decommissioning of their nuclear power stations. The TLG study, initiated in 1987 and completed in 1989, was for the same plant, Washington Public Supply System's Unit 2 (WNP-2), that PNL used as its reference plant in its 1980 decommissioning study. Areas of agreement and disagreement are identified, and reasons for the areas of disagreement are discussed. 31 refs., 3 figs., 22 tabs

  10. Novel Sample-handling Approach for XRD Analysis with Minimal Sample Preparation

    Science.gov (United States)

    Sarrazin, P.; Chipera, S.; Bish, D.; Blake, D.; Feldman, S.; Vaniman, D.; Bryson, C.

    2004-01-01

    Sample preparation and sample handling are among the most critical operations associated with X-ray diffraction (XRD) analysis. These operations require attention in a laboratory environment, but they become a major constraint in the deployment of XRD instruments for robotic planetary exploration. We are developing a novel sample handling system that dramatically relaxes the constraints on sample preparation by allowing characterization of coarse-grained material that would normally be impossible to analyze with conventional powder-XRD techniques.

  11. Microbiological sampling plan based on risk classification to verify supplier selection and production of served meals in food service operation.

    Science.gov (United States)

    Lahou, Evy; Jacxsens, Liesbeth; Van Landeghem, Filip; Uyttendaele, Mieke

    2014-08-01

    Food service operations are confronted with a diverse range of raw materials and served meals. The implementation of a microbial sampling plan in the framework of verification of suppliers and their own production process (functionality of their prerequisite and HACCP program), demands selection of food products and sampling frequencies. However, these are often selected without a well described scientifically underpinned sampling plan. Therefore, an approach on how to set-up a focused sampling plan, enabled by a microbial risk categorization of food products, for both incoming raw materials and meals served to the consumers is presented. The sampling plan was implemented as a case study during a one-year period in an institutional food service operation to test the feasibility of the chosen approach. This resulted in 123 samples of raw materials and 87 samples of meal servings (focused on high risk categorized food products) which were analyzed for spoilage bacteria, hygiene indicators and food borne pathogens. Although sampling plans are intrinsically limited in assessing the quality and safety of sampled foods, it was shown to be useful to reveal major non-compliances and opportunities to improve the food safety management system in place. Points of attention deduced in the case study were control of Listeria monocytogenes in raw meat spread and raw fish as well as overall microbial quality of served sandwiches and salads. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Surface Environmental Surveillance Procedures Manual, PNL-MA-580, Rev. 5

    Energy Technology Data Exchange (ETDEWEB)

    Hanf, Robert W.; Poston, Ted M.; Bisping, Lynn E.

    2007-07-01

    This manual contains the procedures that are used for the collection of routine Surface Environmental Surveillance Project environmental samples and field measurements on and around the Hanford Site. Specific responsibilities for project personnel are also defined.

  13. Retrograde intrarenal surgery versus percutaneous lithotripsy to treat renal stones 2-3 cm in diameter.

    Science.gov (United States)

    Zengin, Kursad; Tanik, Serhat; Karakoyunlu, Nihat; Sener, Nevzat Can; Albayrak, Sebahattin; Tuygun, Can; Bakirtas, Hasan; Imamoglu, M Abdurrahim; Gurdal, Mesut

    2015-01-01

    Retrograde intrarenal surgery (RIRS) performed using a flexible ureterorenoscope marked the beginning of a new era in urology. Today, even staghorn stones are successfully treated via RIRS. The recommended treatment for larger stones is percutaneous nephrolithotomy (PNL). However, the question of whether PNL or RIRS should be the first-line treatment option for larger stones remains controversial. In this study, we contribute to the debate by comparing the success and complication rates of PNL and RIRS that were used to treat renal pelvis stones 2-3 cm in diameter. The medical records of 154 patients (74 PNL, 80 RIRS) were retrospectively evaluated. PNL patients were placed in Group 1 and RIRS patients in Group 2. The complete stone-free rates were 95.5% in the PNL group and 80.6% in the RIRS group 1 month postoperatively (P = 0.061). The respective complication rates (evaluated using the Clavien system) were 13.5% and 8.8% (P = 0.520). RIRS affords a comparable success rate, causes fewer complications than PNL, and seems to be a promising alternative to PNL when larger stones are to be treated. Prospective randomized controlled trials are needed to confirm these findings.

  14. Radiological risk guidelines for nonreactor nuclear facilities at the Pacific Northwest Laboratory

    International Nuclear Information System (INIS)

    Lucas, D.E.; Ikenberry, T.A.

    1994-03-01

    Radiological risk evaluation guidelines for the public and workers have been developed at the Pacific Northwest Laboratory (PNL) based upon the Nuclear Safety Policy of the US Department of Energy (DOE) established in Secretary of Energy Notice SEN-35-91 (DOE 1991). The DOE nuclear safety policy states that the general public be protected-such that no individual bears significant additional risk to health and safety from the operation of a DOE nuclear facility above the risks to which members of the general population are normally exposed. The radiological risk evaluation guidelines developed at PNL are unique in that they are (1) based upon quantitative risk goals and (2) provide a consistent level of risk management. These guidelines are used to evaluate the risk from radiological accidents that may occur during research and development activities at PNL. A safety analyst uses the frequency of the potential accident and the radiological dose to a given receptor to determine if the accident consequences meet the objectives of the Nuclear Safety Policy

  15. Outcomes of miniaturized percutaneous nephrolitotomy in infants: single centre experience

    Directory of Open Access Journals (Sweden)

    Eyyup Sabri Pelit

    Full Text Available ABSTRACT Objectives: The present study was aim to evaluate the safety and efficacy of Mini-PNL to treat kidney stones in patients aged <3 years. This is the one of the largest series in the literature in this age group of patients. Material and methods: From May 2012 to April 2016, the medical records of 74 infant patients who underwent mini-PNL for renal stones were reviewed retrospectively. All infants were evaluated with the plain abdominal radiograph, urinary ultrasound, non-contrast computerized tomography and/or intravenous urogram. Pre-operative, intraoperative and post-operative data were analyzed. Results: A total of 74 infant (42 male, 32 female with a mean age 21.5±8.2 (10-36 months were included in this study. The mean size of the stones was 22.0±5.9 (14-45 mm. A 17 Fr rigid pediatric nephroscope with a pneumatic intracorporeal lithotripsy were used through 20-22 Fr access sheath. The stone-free rate was 84.7% at 1 month after the operation. Mean operative time was 74.0 (40-140 min. Mean fluoroscopy screening time was as 4.3(3.1-8.6 min. Average hospitalization time was 3.8 (2-9 day. Auxiliary procedures were performed to 11(15.3% patients (7 extracorporeal shock wave lithotripsy, 3 re- percutaneous nephrolitotomy, 1 retrograde intrarenal surgery. No major complication classified as Clavien IV-V observed in study group. Conclusions: Mini-PNL with pneumatic intracorporeal lithotripsy can be performed safely and effectively to manage kidney stones in infants with high stone free rate and low complications.

  16. Does Diabetes Affect the Outcome of Percutaneous Nephrolithotomy?

    Directory of Open Access Journals (Sweden)

    Emrah Yürük

    2010-09-01

    Full Text Available Aim: The increased mortality and morbidity in diabetic patients who underwent cardiac surgery is well documented. However, there are few data about non-cardiac surgical interventions. This study is designed to evaluate whether diabetes has any effects on outcome of percutaneous nephrolithotomy (PNL. Methods: The records of 1658 patients who underwent PNL between October 2002 and December 2009 in our clinic were retrospectively analyzed. Data of patients with diagnosis of diabetes mellitus (group 1, 231 patients were compared with data of patients without diabetes (group 2, 1427 patients by means of operative and postoperative findings. Results: Complete stone clearance was achieved in 206 (89.1% patients in group 1 and 1355 (94.9% patients in group 2 (p:0.000. Auxiliary treatment modalities were needed in 44 (19.0% diabetic and 153 (10.7% non-diabetic patients (p:0.000. In diabetic patients, operation and hospitalization time, and time of nephrostomy tube removal were significantly longer. In addition, bleeding, fever and urosepsis rates were significantly higher in diabetic patients. Conclusion: PNL in diabetics is an effective procedure with acceptable complication rates in the treatment of renal stones. However, the increased risk of bleeding and infection needs extra attention in diabetic patients when compared with non-diabetics. (The Medical Bulletin of Haseki 2010; 48: 80-4

  17. Environmental monitoring at Hanford for 1986

    International Nuclear Information System (INIS)

    1987-05-01

    Environmental monitoring at the Hanford Site is conducted by the Battelle Memorial Institute, Pacific Northwest Division, as part of its contract to operate the Pacific Northwest Laboratory (PNL) for the US Department of Energy. The data collected provide a historical record of the levels of radionuclides and radiation attributable to natural causes, worldwide fallout, and Hanford operations. Data are also collected to monitor the status of chemical materials on the Site and in the Columbia River. This report represents a single, comprehensive source of environmental monitoring data collected during 1986 by PNL's Environmental monitoring Group in the offsite and onsite environments. Appendix A contains data and data summaries for results obtained during 1986 that include statistical estimates of variation. Information in Appendix A is intended for readers with a scientific interest or for those who wish to evaluate results in a manner not included here. 71 refs., 66 figs., 17 tabs

  18. Percutaneous nephrolithotomy vs. extracorporeal shockwave lithotripsy for treating a 20-30 mm single renal pelvic stone.

    Science.gov (United States)

    Hassan, Mohammed; El-Nahas, Ahmed R; Sheir, Khaled Z; El-Tabey, Nasr A; El-Assmy, Ahmed M; Elshal, Ahmed M; Shokeir, Ahmed A

    2015-09-01

    To compare the efficacy, safety and cost of extracorporeal shockwave lithotripsy (ESWL) and percutaneous nephrolithotomy (PNL) for treating a 20-30 mm single renal pelvic stone. The computerised records of patients who underwent PNL or ESWL for a 20-30 mm single renal pelvic stone between January 2006 and December 2012 were reviewed retrospectively. Patients aged PNL. The re-treatment rate (75% vs. 5%), the need for secondary procedures (25% vs. 4.7%) and total number of procedures (three vs. one) were significantly higher in the ESWL group (P PNL group (95% vs. 75%, P PNL (US$ 1120 vs. 490; P PNL was more effective than ESWL for treating a single renal pelvic stone of 20-30 mm. However, ESWL was associated with fewer complications and a lower cost.

  19. Family support, family stress, and suicidal ideation in a combat-exposed sample of Operation Enduring Freedom/Operation Iraqi Freedom veterans.

    Science.gov (United States)

    Gradus, Jaimie L; Smith, Brian N; Vogt, Dawne

    2015-01-01

    Deployment-related risk factors for suicidal ideation among Operation Enduring Freedom (OEF) and Operation Iraqi Freedom (OIF) veterans have received a great deal of attention. Studies show that mental health symptoms mediate the association between most deployment stressors and suicidal ideation; however, family-related factors during deployment are largely unexplored. We examined posttraumatic stress disorder (PTSD) and depression symptoms as mediators of the associations between deployment family support and stress and post-deployment suicidal ideation in combat-exposed OEF/OIF veterans. National cross-sectional mail survey. 1046 veterans responded to the survey. The sample for this study was 978 veterans who experienced combat. Regression-based path analyses were conducted. Family support and stress had direct associations with suicidal ideation. When PTSD and depression symptoms were examined as mediators of these associations, results revealed significant indirect paths through these symptoms. This study contributes to the literature on suicidal ideation risk factors among OEF/OIF veterans. Deployment family support and family stress are associated with suicidal ideation; however these associations occur primarily through mental health symptomatology, consistent with findings observed for other deployment factors. This research supports ongoing efforts to treat mental health symptomatology as a means of suicide prevention.

  20. Monitoring PCDD/Fs in soil and herbage samples collected in the neighborhood of a hazardous waste incinerator after five years of operation

    Energy Technology Data Exchange (ETDEWEB)

    Nadal, M.; Bocio, A.; Schuhmacher, M.; Liobet, J.M.; Domingo, J.L. [Rovira i Virgili Univ., Reus (Spain); Diaz-Ferrero, J. [Inst. Quimic de Sarria, Barcelona (Spain)

    2004-09-15

    Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) are among the most dangerous environmental pollutants, usually generated during combustion processes. Until recently, waste incineration was widely referenced as one of the most important sources of PCDD/F release to the atmosphere. In 1999, the only hazardous waste incinerator (HWI) in Spain began regular operations. This facility is placed in Tarragona, Catalonia. The presence of this HWI, as well as that of a municipal solid waste incinerator (MSWI) at a few kilometers, increased the concern of the public opinion in relation to the potential toxic emissions, especially those of metals and PCDD/Fs, which could affect the health of the population living in the area. Previously to regular operations (1996) the baseline levels of PCDD/Fs in soil and vegetation samples collected near the HWI were determined. A second survey was carried out two years later (1998) in order to establish the temporal variation in PCDD/F concentrations in soil and vegetation samples taken at the same sampling points. Vegetation is considered an adequate short-term environmental monitor for PCDD/Fs. Therefore, in the surveillance program of the facility (1999-2003), herbage samples (40) were annually collected at the same sampling points in which baseline samples had been taken. Moreover, considering soil as a suitable long-term monitor for PCDD/Fs, 40 soil samples in this matrix were again collected in 2001 and 2003 to examine the temporal variations of PCDD/F levels in the area. In the present study, we present the concentrations of PCDD/Fs in soil and vegetation samples collected in the vicinity of the HWI after 5 years of regular operations.

  1. Sampling in practice

    DEFF Research Database (Denmark)

    Esbensen, Kim Harry; Petersen, Lars

    2005-01-01

    A basic knowledge of the Theory of Sampling (TOS) and a set of only eight sampling unit operations is all the practical sampler needs to ensure representativeness of samples extracted from all kinds of lots: production batches, - truckloads, - barrels, sub-division in the laboratory, sampling...... in nature and in the field (environmental sampling, forestry, geology, biology), from raw materials or manufactory processes etc. We here can only give a brief introduction to the Fundamental Sampling Principle (FSP) and these eight Sampling Unit Operations (SUO’s). Always respecting FSP and invoking only...... the necessary SUO’s (dependent on the practical situation) is the only prerequisite needed for eliminating all sampling bias and simultaneously minimizing sampling variance, and this is in addition a sure guarantee for making the final analytical results trustworthy. No reliable conclusions can be made unless...

  2. Comparative Study between Standard and Totally Tubeless Percutaneous Nephrolithotomy

    OpenAIRE

    Yun, Sung Il; Lee, Yoon Hyung; Kim, Jae Soo; Cho, Sung Ryong; Kim, Bum Soo; Kwon, Joon Beom

    2012-01-01

    Purpose Several recent studies have reported the benefits of tubeless percutaneous nephrolithotomy (PNL). Postoperatively, tubeless PNL patients have an indwelling ureteral stent placed, which is often associated with stent-related morbidity. We have performed totally tubeless (tubeless and stentless) PNL in which no nephrostomy tube or ureteral stent is placed postoperatively. We evaluated the safety, effectiveness, and feasibility of totally tubeless PNL. Materials and Methods From March 20...

  3. PFP Wastewater Sampling Facility

    International Nuclear Information System (INIS)

    Hirzel, D.R.

    1995-01-01

    This test report documents the results obtained while conducting operational testing of the sampling equipment in the 225-WC building, the PFP Wastewater Sampling Facility. The Wastewater Sampling Facility houses equipment to sample and monitor the PFP's liquid effluents before discharging the stream to the 200 Area Treated Effluent Disposal Facility (TEDF). The majority of the streams are not radioactive and discharges from the PFP Heating, Ventilation, and Air Conditioning (HVAC). The streams that might be contaminated are processed through the Low Level Waste Treatment Facility (LLWTF) before discharging to TEDF. The sampling equipment consists of two flow-proportional composite samplers, an ultrasonic flowmeter, pH and conductivity monitors, chart recorder, and associated relays and current isolators to interconnect the equipment to allow proper operation. Data signals from the monitors are received in the 234-5Z Shift Office which contains a chart recorder and alarm annunciator panel. The data signals are also duplicated and sent to the TEDF control room through the Local Control Unit (LCU). Performing the OTP has verified the operability of the PFP wastewater sampling system. This Operability Test Report documents the acceptance of the sampling system for use

  4. Intra-operative cerebrospinal fluid sampling versus post-operative lumbar puncture for detection of leptomeningeal disease in malignant paediatric brain tumours.

    Directory of Open Access Journals (Sweden)

    Sharon Y Y Low

    Full Text Available Leptomeningeal disease is a feared sequelae of malignant paediatric brain tumours. Current methods for its detection is the combined use of cranio-spinal MRI, and CSF cytology from a post-operative lumbar puncture. In this study, the authors hypothesize that CSF taken at the start of surgery, either from an external ventricular drain or neuroendoscope will have equal sensitivity for positive tumour cells, in comparison to lumbar puncture. Secondary hypotheses include positive correlation between CSF cytology and MRI findings of LMD. From a clinical perspective, the key aim of the study was for affected paediatric patients to avoid an additional procedure of a lumbar puncture, often performed under anaesthesia after neurosurgical intervention.This is single-institution, retrospective study of paediatric patients diagnosed with malignant brain tumours. Its main aim was to compare cytological data from CSF collected at the time of surgery versus data from an interval lumbar puncture. In addition, MRI imaging of the same cohort of patients was examined for leptomeningeal disease and corroborated against CSF tumour cytology findings.Thirty patients are recruited for this study. Data analysis demonstrates a statistically significant association between our intra-operative CSF and LP sampling. Furthermore, our results also show for significant correlation between evidence of leptomeningeal disease on MRI findings versus intra-operative CSF positivity for tumour cells.Although this is a retrospective study with a limited population, our data concurs with potential to avoid an additional procedure for the paediatric patient diagnosed with a malignant brain tumour.

  5. Studies of materials found in products and wastes from coal-conversion processes

    International Nuclear Information System (INIS)

    Petersen, M.R.; Fruchter, J.S.

    1979-01-01

    Researchers at Pacific Northwest Laboratory (PNL) have been investigating materials from synthetic fossil-fuel processes. During this past year, solids from the Lignite Gasification Pilot Plant and samples from the Solvent Refined Coal Pilot Plant (SRC-II mode) have been analyzed for organic and inorganic constituents. Observations on these samples are summarized

  6. Pure neuritic leprosy: Resolving diagnostic issues in acid fast bacilli (AFB)-negative nerve biopsies: A single centre experience from South India.

    Science.gov (United States)

    Hui, Monalisa; Uppin, Megha S; Challa, Sundaram; Meena, A K; Kaul, Subhash

    2015-01-01

    Demonstration of lepra bacilli is essential for definite or unequivocal diagnosis of pure neuritic leprosy (PNL) on nerve biopsy. However, nerves always do not show bacilli owing to the changes of previous therapy or due to low bacillary load in tuberculoid forms. In absence of granuloma or lepra bacilli, other morphologic changes in endoneurium and perineurium can be of help in making a probable diagnosis of PNL and treating the patient with multidrug therapy. Forty-six biopsies of PNL were retrospectively reviewed and histologic findings were compared with 25 biopsies of non leprosy neuropathies (NLN) including vasculitic neuropathy and chronic inflammatory demyelinating polyneuropathy (CIDP). The distribution of endoneurial infiltrate and fibrosis, perineurial thickening, and myelin abnormalities were compared between PNL and NLN biopsies and analyzed by Chi-square test. Out of 46 PNL casses, 24 (52.17 %) biopsies were negative for acid fast bacilli (AFB). In these cases, the features which favor a diagnosis of AFB-negative PNL were endoneurial infiltrate (51.1%), endoneurial fibrosis (54.2%), perineurial thickening (70.8%), and reduced number of myelinated nerve fibers (75%). Nerve biopsy is an efficient tool to diagnose PNL and differentiate it from other causes of NLN. In absence of AFB, the diagnosis of PNL is challenging. In this article, we have satisfactorily evaluated the various hisopthological features and found that endoneurial inflammation, dense fibrosis, and reduction in the number of myelinated nerve fibers are strong supportive indicators of PNL regardless of AFB positivity.

  7. Percutaneous nephrolithotomy is highly efficient and safe in infants and children under 3 years of age.

    Science.gov (United States)

    Guven, Selcuk; Istanbulluoglu, Okan; Ozturk, Ahmet; Ozturk, Bulent; Piskin, Mesut; Cicek, Tufan; Kilinc, Mehmet; Ozkardes, Hakan; Arslan, Mehmet

    2010-01-01

    We aimed to evaluate the efficacy and safety of percutaneous nephrolithotomy (PNL) in infants and small children (12-36 months). The PNL applications conducted in children PNL instrumentation was used in the first center, adult-size instrumentation was utilized in the second center. The complications were given according to the modified Clavien classification system. The mean age of the patients was 22.76 months (5-36 months) and the mean body weight was 11.51 kg (6-15 kg). In twelve renal units, pediatric instrumentation was used and among these, two had miniperc. In the other eight renal units, adult-size instrumentation was employed. Except for the patient with complex renal stones, all patients were stone free after the intervention and none required a conversion to open surgery. There were grade 1-2 complications in 3 patients. The postoperative hemoglobin drop was greater in the children who underwent PNL with adult-size instrumentation. In this young age group, in addition to standard PNL, simultaneous bilateral PNL, tubeless PNL and in urgent cases of renal failure, urgent PNL, are safe and effective treatment modalities provided patients are selected properly and the surgeon performing the procedure has the necessary experience. Copyright © 2010 S. Karger AG, Basel.

  8. Retrograde Intrarenal Surgery versus Percutaneous Lithotripsy to Treat Renal Stones 2-3 cm in Diameter

    Directory of Open Access Journals (Sweden)

    Kursad Zengin

    2015-01-01

    Full Text Available Objective. Retrograde intrarenal surgery (RIRS performed using a flexible ureterorenoscope marked the beginning of a new era in urology. Today, even staghorn stones are successfully treated via RIRS. The recommended treatment for larger stones is percutaneous nephrolithotomy (PNL. However, the question of whether PNL or RIRS should be the first-line treatment option for larger stones remains controversial. In this study, we contribute to the debate by comparing the success and complication rates of PNL and RIRS that were used to treat renal pelvis stones 2-3 cm in diameter. Materials and Methods. The medical records of 154 patients (74 PNL, 80 RIRS were retrospectively evaluated. PNL patients were placed in Group 1 and RIRS patients in Group 2. Results. The complete stone-free rates were 95.5% in the PNL group and 80.6% in the RIRS group 1 month postoperatively (P=0.061. The respective complication rates (evaluated using the Clavien system were 13.5% and 8.8% (P=0.520. Conclusions. RIRS affords a comparable success rate, causes fewer complications than PNL, and seems to be a promising alternative to PNL when larger stones are to be treated. Prospective randomized controlled trials are needed to confirm these findings.

  9. Direct pelvic access percutaneous nephrolithotomy in management of ectopic kidney stone: a case report and literature review.

    Science.gov (United States)

    Mehmet, Rifaioglu Murat; Rustu, Yalcinkaya Fatih; Hanefi, Bayarogullari; Mursel, Davarci; Fusun, Aydogan; Mehmet, Inci

    2013-01-01

    Percutaneous nephrolithotomy (PNL) is an effective procedure for the treatment of patients with large or complex stones. PNL is challenging in anomalous kidneys, certain patients, such as those with renal ectopia. It is unable to undergo PNL in conventional technique safely in these cases. We presented a case report of laparoscopic-assisted PNL via direct pelvic puncture in a pelvic kidney stone and discussed previous published literature. A 49-year-old man presented with right lower quadrant pain and hematuria. Intravenous pyelography and three-dimensional computerized tomography revealed an opaque 2.7 × 1.7 cm pelvis renalis stone in a right side ectopic pelvic kidney with grade III hydronephrosis. Laparoscopic-assisted tubeless PNL was performed to remove the calculus. Laparoscopic-assisted PNL as a minimally invasive therapy in ectopic kidney has many advantages. Our case showed that, in pelvic ectopic kidney with pelvic stones greater than 1.5 cm in size, laparoscopic-assisted PNL via direct pelvis puncture is a safe and effective technique.

  10. Minimizing radiation exposure during percutaneous nephrolithotomy.

    Science.gov (United States)

    Chen, T T; Preminger, G M; Lipkin, M E

    2015-12-01

    Given the recent trends in growing per capita radiation dose from medical sources, there have been increasing concerns over patient radiation exposure. Patients with kidney stones undergoing percutaneous nephrolithotomy (PNL) are at particular risk for high radiation exposure. There exist several risk factors for increased radiation exposure during PNL which include high Body Mass Index, multiple access tracts, and increased stone burden. We herein review recent trends in radiation exposure, radiation exposure during PNL to both patients and urologists, and various approaches to reduce radiation exposure. We discuss incorporating the principles of As Low As reasonably Achievable (ALARA) into clinical practice and review imaging techniques such as ultrasound and air contrast to guide PNL access. Alternative surgical techniques and approaches to reducing radiation exposure, including retrograde intra-renal surgery, retrograde nephrostomy, endoscopic-guided PNL, and minimally invasive PNL, are also highlighted. It is important for urologists to be aware of these concepts and techniques when treating stone patients with PNL. The discussions outlined will assist urologists in providing patient counseling and high quality of care.

  11. Hanford Site environmental data for calendar year 1993--surface and Columbia River

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1994-06-01

    Environmental monitoring at the Hanford Site, located in southeastern Washington State, is conducted by Battelle Memorial Institute, Pacific Northwest Division, as part of its contract to operate the Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy. The data collected provide a historical record of radionuclide and radiation levels attributable to natural causes, worldwide fallout, and Hanford operations. Data are also collected to monitor several chemicals. Pacific Northwest Laboratory publishes an annual environmental report for the Hanford Site each calendar year. The Hanford Site Environmental Report for Calendar Year 1993 describes the Site mission and activities, general environmental features, radiological and chemical releases from operations, status of compliance with environmental regulations, status of programs to accomplish compliance, and environmental monitoring activities and results. The report includes a summary of offsite and onsite environmental monitoring data collected during 1993 by PNL's Environmental Monitoring Program. Appendix A of that report contains data summaries created from raw surface and river monitoring data. This volume contains the actual raw data used to create the summaries

  12. Hanford Site environmental data for calendar year 1994: Surface and Columbia River

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1995-07-01

    Environmental monitoring at the Hanford Site, located in southeastern Washington State, is conducted by Battelle Memorial Institute, Pacific Northwest Division, as part of its contract to operate the Pacific Northwest Laboratory (PNL) for the US Department of Energy. The data collected provide a historical record of radionuclide and radiation levels attributable to natural causes, worldwide fallout, and Hanford operations. Data are also collected to monitor several chemicals. Pacific Northwest Laboratory publishes an annual environmental report for the Hanford Site each calendar year. The Hanford Site Environmental Report for Calendar Year 1994 describes the Site mission and activities, general environmental features, radiological and chemical releases from operations, status of compliance with environmental regulations, status of programs to accomplish compliance, and environmental monitoring activities and results. The report includes a summary of offsite and onsite environmental monitoring data collected during 1994 b PNL's Environmental Monitoring Program. Appendix A of that report contains data summaries created from raw surface and river monitoring data. This volume contains the actual raw data used to create the summaries

  13. Hanford Site environmental data for calendar year 1994: Surface and Columbia River

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1995-07-01

    Environmental monitoring at the Hanford Site, located in southeastern Washington State, is conducted by Battelle Memorial Institute, Pacific Northwest Division, as part of its contract to operate the Pacific Northwest Laboratory (PNL) for the US Department of Energy. The data collected provide a historical record of radionuclide and radiation levels attributable to natural causes, worldwide fallout, and Hanford operations. Data are also collected to monitor several chemicals. Pacific Northwest Laboratory publishes an annual environmental report for the Hanford Site each calendar year. The Hanford Site Environmental Report for Calendar Year 1994 describes the Site mission and activities, general environmental features, radiological and chemical releases from operations, status of compliance with environmental regulations, status of programs to accomplish compliance, and environmental monitoring activities and results. The report includes a summary of offsite and onsite environmental monitoring data collected during 1994 b PNL`s Environmental Monitoring Program. Appendix A of that report contains data summaries created from raw surface and river monitoring data. This volume contains the actual raw data used to create the summaries.

  14. Hanford Site environmental data for calendar year 1993--surface and Columbia River

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1994-06-01

    Environmental monitoring at the Hanford Site, located in southeastern Washington State, is conducted by Battelle Memorial Institute, Pacific Northwest Division, as part of its contract to operate the Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy. The data collected provide a historical record of radionuclide and radiation levels attributable to natural causes, worldwide fallout, and Hanford operations. Data are also collected to monitor several chemicals. Pacific Northwest Laboratory publishes an annual environmental report for the Hanford Site each calendar year. The Hanford Site Environmental Report for Calendar Year 1993 describes the Site mission and activities, general environmental features, radiological and chemical releases from operations, status of compliance with environmental regulations, status of programs to accomplish compliance, and environmental monitoring activities and results. The report includes a summary of offsite and onsite environmental monitoring data collected during 1993 by PNL`s Environmental Monitoring Program. Appendix A of that report contains data summaries created from raw surface and river monitoring data. This volume contains the actual raw data used to create the summaries.

  15. Determination of 228Th, 230Th, and 232Th in environmental samples from uranium mining and milling operations

    International Nuclear Information System (INIS)

    Durham, R.W.; Joshi, S.R.

    1979-01-01

    A method is described for the determination of 228 Th, 230 Th, and 232 Th in environmental samples from uranium mining and milling operations. The analytical procedure is based on the direct determination of 228 Th in the sample by high resolution γ-spectrometry followed by extraction and purification of the thorium fraction using high molecular weight amines and an anion-exchange technique, respectively, prior to α-spectrometry to determine isotopic ratios. The lowest level of detection for each thorium isotope is 0.01 pCi/g for solid samples and 20 pCi/l for aqueous samples. Replicate analyses of a typical mine waste stream gave a standard deviation of +-3% for 228 Th. Standard deviations of the 230 Th and 232 Th increased to +-11% apparently due to traces of 210 Po interfering in the α-spectrometry. (author)

  16. The Cost-Effectiveness of Treatment Modalities for Ureteral Stones

    Directory of Open Access Journals (Sweden)

    Justin Ji-Yuen Siu MD

    2016-10-01

    Full Text Available Additional intervention and medical treatment of complications may follow the primary treatment of a ureteral stone. We investigated the cost of the treatment of ureteral stone(s within 45 days after initial intervention by means of retrospective analysis of the National Health Insurance Research Database of Taiwan. All patients of ages ≥20 years diagnosed with ureteral stone(s( International Classification of Diseases, Ninth Revision, Clinical Modification/ICD-9-CM: 592.1 from January 2001 to December 2011 were enrolled. We included a comorbidity code only if the diagnosis appeared in at least 2 separate claims in a patient’s record. Treatment modalities (code included extracorporeal shock-wave lithotripsy (SWL; 98.51, ureteroscopic lithotripsy (URSL; 56.31, percutaneous nephrolithotripsy (PNL; 55.04, (open ureterolithotomy (56.20, and laparoscopy (ie, laparoscopic ureterolithotomy; 54.21. There were 28 513 patients with ureteral stones (13 848 men and 14 665 women in the randomized sample of 1 million patients. The mean cost was 526.4 ± 724.1 United States Dollar (USD. The costs of treatment were significantly increased in patients with comorbidities. The costs of treatment among each primary treatment modalities were 1212.2 ± 627.3, 1146.7 ± 816.8, 2507.4 ± 1333.5, 1533.3 ± 1137.1, 2566.4 ± 2594.3, and 209.8 ± 473.2 USD in the SWL, URSL, PNL, (open ureterolithotomy, laparoscopy (laparoscopic ureterolithotomy, and conservative treatment group, respectively. In conclusion, URSL was more cost-effective than SWL and PNL as a primary treatment modality for ureteral stone(s when the possible additional costs within 45 days after the initial operation were included in the calculation.

  17. Comparison of Infection and Urosepsis Rates of Ciprofloxacin and Ceftriaxone Prophylaxis before Percutaneous Nephrolithotomy: A Prospective and Randomised Study

    Directory of Open Access Journals (Sweden)

    Abdullah Demirtas

    2012-01-01

    Full Text Available This study aimed at determining the choice and administration duration of ideal antibiotic prophylaxis before percutaneous nephrolithotomy (PNL operation, a treatment modality for nephrolithiasis. The study included 90 patients who had no internal problem, yet had a negative urine culture and underwent a PNL operation. We compared infection rates between ciprofloxacin and ceftriaxone groups and their subgroups. The results showed no statistical difference between ciprofloxacin and ceftriaxone groups in terms of systemic inflammatory response syndrome (SIRS (CIPP=0.306, CTX P=0.334. As a result of this study no statistical difference was observed between ciprofloxacin and ceftriaxone in terms of SIRS. It seems, however, reasonable to choose ceftriaxone, considering antibiotic sensitivity of microorganisms and detection of three cases accepted as urosepsis in the ciprofloxacin group. As there is no difference between short, and long-term prophylactic use of these antibiotics, preference of short-term prophylaxis for patients with no risk of infection will be important to avoid inappropriate antibiotic usage.

  18. Current practices for maintaining occupational exposures ALARA at low-level waste disposal sites

    International Nuclear Information System (INIS)

    Hadlock, D.E.; Herrington, W.N.; Hooker, C.D.; Murphy, D.W.; Gilchrist, R.L.

    1983-12-01

    The United States Nuclear Regulatory Commission contracted with Pacific Northwest Laboratory (PNL) to provide technical assistance in establishing operational guidelines, with respect to radiation control programs and methods of minimizing occupational radiation exposure, at Low-Level Waste (LLW) disposal sites. The PNL, through site visits, evaluated operations at LLW disposal sites to determine the adequacy of current practices in maintaining occupational exposures as low as is reasonably achievable (ALARA). The data sought included the specifics of: ALARA programs, training programs, external exposure control, internal exposure control, respiratory protection, surveillance, radioactive waste management, facilities and equipment, and external dose analysis. The results of the study indicated the following: The Radiation Protection and ALARA programs at the three commercial LLW disposal sites were observed to be adequate in scope and content compared to similar programs at other types of nuclear facilities. However, it should be noted that there were many areas that could be improved upon to help ensure the health and safety of occupationally exposed individuals

  19. Integrated environmental monitoring program at the Hanford Site

    International Nuclear Information System (INIS)

    Jaquish, R.E.

    1990-08-01

    The US Department of Energy's Hanford Site, north of Richland, Washington, has a mission of defense production, waste management, environmental restoration, advanced reactor design, and research development. Environmental programs at Hanford are conducted by Pacific Northwest Laboratory (PNL) and the Westinghouse Hanford Company (WHC). The WHC environmental programs include the compliance and surveillance activities associated with site operations and waste management. The PNL environmental programs address the site-wide and the of-site areas. They include the environmental surveillance and the associated support activities, such as dose calculations, and also the monitoring of environmental conditions to comply with federal and state environmental regulations on wildlife and cultural resources. These are called ''independent environmental programs'' in that they are conducted completely separate from site operations. The Environmental Surveillance and Oversight Program consists of the following projects: surface environmental surveillance; ground-water surveillance; wildlife resources monitoring; cultural resources; dose overview; radiation standards and calibrations; meteorological and climatological services; emergency preparedness

  20. Current practices for maintaining occupational exposures ALARA at low-level waste disposal sites

    Energy Technology Data Exchange (ETDEWEB)

    Hadlock, D.E.; Herrington, W.N.; Hooker, C.D.; Murphy, D.W.; Gilchrist, R.L.

    1983-12-01

    The United States Nuclear Regulatory Commission contracted with Pacific Northwest Laboratory (PNL) to provide technical assistance in establishing operational guidelines, with respect to radiation control programs and methods of minimizing occupational radiation exposure, at Low-Level Waste (LLW) disposal sites. The PNL, through site visits, evaluated operations at LLW disposal sites to determine the adequacy of current practices in maintaining occupational exposures as low as is reasonably achievable (ALARA). The data sought included the specifics of: ALARA programs, training programs, external exposure control, internal exposure control, respiratory protection, surveillance, radioactive waste management, facilities and equipment, and external dose analysis. The results of the study indicated the following: The Radiation Protection and ALARA programs at the three commercial LLW disposal sites were observed to be adequate in scope and content compared to similar programs at other types of nuclear facilities. However, it should be noted that there were many areas that could be improved upon to help ensure the health and safety of occupationally exposed individuals.

  1. Percutaneous nephrolithotomy in pediatric patients: is computerized tomography a must?

    Science.gov (United States)

    Gedik, Abdullah; Tutus, Ali; Kayan, Devrim; Yılmaz, Yakup; Bircan, Kamuran

    2011-02-01

    The aim of this study was to retrospectively evaluate the results of pediatric percutaneous nephrolithotomy (PNL) cases, and discuss the results and necessity of non-contrast computerized tomography (CT) in these cases. In all, 48 pediatric patients who underwent PNL were retrospectively evaluated. Before PNL, either intravenous urography or CT was performed. In all patients, we evaluated the PNL time, scopy time with stone burden, and complications. During the PNL procedure, we switched to open surgery in two cases: in one because of renal pelvis perforation and in the other because of transcolonic access. In one patient who was scheduled to undergo PNL, we performed open surgery, primarily because we detected a retrorenal colon with CT. The stone burden in 45 patients who underwent PNL was 445 ± 225 mm(2), the PNL time was 51 ± 23 min, and the scopy time was 6.1 ± 2.7 min. We removed nephrostomy tubes 1-4 days after the procedure. In two patients, 24 h after removal of nephrostomy tubes, we inserted double J stents because of prolonged urine extravasation from the tract. In all, 34 of the 45 patients were stone-free, 5 patients had clinically insignificant stone fragments, and 6 patients had residual stones. PNL is a safe and effective method in the treatment of pediatric patients with kidney stones. Clinical experience is the most important factor in obtaining stone-free results. CT should be performed in all pediatric patients in order to prevent colon perforation.

  2. Percutaneous nephrolithotomy in ectopically located kidneys and in patients with musculoskeletal deformities.

    Science.gov (United States)

    Srivastava, A; Gupta, P; Chaturvedi, S; Singh, P; Kapoor, R; Dubey, D; Kumar, A

    2010-01-01

    To assess the feasibility, safety and results of percutaneous nephrolithotomy (PNL) in ectopically located kidneys and in patients with musculoskeletal deformities. Thirteen such patients underwent PNL between June 2005 and May 2008. Mean stone size was 27.4 mm (16-37 mm). Six patients had severe kyphoscoliosis, 2 patients each had achondroplasia, cross-fused ectopia and pelvic ectopic kidney, and 1 patient had thoracic kidney. All had a preoperative CT scan of the abdomen. Preoperative ultrasound- or CT-guided percutaneous nephrostomy (PCN) was done in 10 patients. Three patients underwent laparoscopic-assisted PNL. All underwent standard PNL. The stone-free rate, complication rate and need for secondary intervention were evaluated. PNL was successfully completed in all. A second ultrasound-guided intraoperative puncture was required in 2 patients. Re-look PNL was required in 1 patient and the same patient later required shock wave lithotripsy for complete stone clearance. The remaining 12 patients (92.3%) were rendered stone-free in a single sitting. PNL is a feasible and effective modality in anomalous kidneys. Preoperative planning with CT and image-guided PCN is helpful in these situations. Laparoscopic-assisted PNL can be safely performed in patients where access to a renal collecting system by fluoroscopy or image-guided assistance (ultrasound or CT scan) is not possible. Copyright (c) 2010 S. Karger AG, Basel.

  3. Qualitative and quantitative analysis of the saponins in Panax notoginseng leaves using ultra-performance liquid chromatography coupled with time-of-flight tandem mass spectrometry and high performance liquid chromatography coupled with UV detector.

    Science.gov (United States)

    Liu, Fang; Ma, Ni; He, Chengwei; Hu, Yuanjia; Li, Peng; Chen, Meiwan; Su, Huanxing; Wan, Jian-Bo

    2018-04-01

    Panax notoginseng leaves (PNL) exhibit extensive activities, but few analytical methods have been established to exclusively determine the dammarane triterpene saponins in PNL. Ultra-performance liquid chromatography coupled with time-of-flight mass spectrometry (UPLC/Q-TOF MS) and HPLC-UV methods were developed for the qualitative and quantitative analysis of ginsenosides in PNL, respectively. Extraction conditions, including solvents and extraction methods, were optimized, which showed that ginsenosides Rc and Rb3, the main components of PNL, are transformed to notoginsenosides Fe and Fd, respectively, in the presence of water, by removing a glucose residue from position C-3 via possible enzymatic hydrolysis. A total of 57 saponins were identified in the methanolic extract of PNL by UPLC/Q-TOF MS. Among them, 19 components were unambiguously characterized by their reference substances. Additionally, seven saponins of PNL-ginsenosides Rb1, Rc, Rb2, and Rb3, and notoginsenosides Fc, Fe, and Fd-were quantified using the HPLC-UV method after extraction with methanol. The separation of analytes, particularly the separation of notoginsenoside Fc and ginsenoside Rc, was achieved on a Zorbax ODS C8 column at a temperature of 35°C. This developed HPLC-UV method provides an adequate linearity ( r 2  > 0.999), repeatability (relative standard deviation, RSD PNL. These findings are beneficial to the quality control of PNL and its relevant products.

  4. Clinical efficacy and safety of transcatheter embolization for vascular complications after percutaneous nephrolithotomy.

    Science.gov (United States)

    Poyraz, Necdet; Balasar, Mehmet; Gökmen, İbrahim Erdem; Koç, Osman; Sönmez, Mehmet Giray; Aydın, Arif; Göger, Yunus Emre; Öztürk, Ahmet

    2017-12-01

    Percutaneous nephrolithotomy (PNL) is the preferred procedure for safe and effective surgical treatment of kidney stones. Hemorrhage is the most serious complication of PNL, resulting from pseudoaneurysm (PA) or arteriovenous fistula (AVF), and can usually be controlled with conservative treatment. To evaluate endovascular treatments and outcomes of vascular complications observed after PNL. We retrospectively reviewed data on 19 patients who underwent renal embolization due to post-PNL renal artery bleeding between March 2005 and September 2016. Embolization materials included embolization coils and glue. The incidence of post-PNL vascular complications and their endovascular treatments, outcomes, and the follow-up data were analyzed. Nineteen (1.1%) of 1,609 patients (mean age: 44.9 years, range: 19-75 years) underwent angiography and subsequent transcatheter embolization to control bleeding. The mean time to onset of hemorrhage was 7.2 days after PNL (range: 3-18 days). The PNL entry site was the lower calyx in 15 patients, the middle calyx in 3, and the upper calyx in 1. PA, AVF, and PA plus AVF occurred in 14, 5, and 3 of the 19 renal angiography patients, respectively. Embolization of the affected vessels was successful in all 19 patients. The embolization materials of coil, glue, and coil plus glue were used in 16, 3, and 2 patients, respectively. Severe hematuria is a rare complication of PNL and can be successfully treated with transcatheter embolization.

  5. Procedures for ground-water investigations

    International Nuclear Information System (INIS)

    1992-12-01

    This manual was developed by the Pacific Northwest Laboratory (PNL) to document the procedures used to carry out and control the technical aspects of ground-water investigations at the PNL. Ground-water monitoring procedures are developed and used in accordance with the PNL Quality Assurance Program

  6. Ammonia and ammonium hydroxide sensors for ammonia/water absorption machines: Literature review and data compilation

    Energy Technology Data Exchange (ETDEWEB)

    Anheier, N.C. Jr.; McDonald, C.E.; Cuta, J.M.; Cuta, F.M.; Olsen, K.B.

    1995-05-01

    This report describes an evaluation of various sensing techniques for determining the ammonia concentration in the working fluid of ammonia/water absorption cycle systems. The purpose of this work was to determine if any existing sensor technology or instrumentation could provide an accurate, reliable, and cost-effective continuous measure of ammonia concentration in water. The resulting information will be used for design optimization and cycle control in an ammonia-absorption heat pump. PNL researchers evaluated each sensing technology against a set of general requirements characterizing the potential operating conditions within the absorption cycle. The criteria included the physical constraints for in situ operation, sensor characteristics, and sensor application. PNL performed an extensive literature search, which uncovered several promising sensing technologies that might be applicable to this problem. Sixty-two references were investigated, and 33 commercial vendors were identified as having ammonia sensors. The technologies for ammonia sensing are acoustic wave, refractive index, electrode, thermal, ion-selective field-effect transistor (ISFET), electrical conductivity, pH/colormetric, and optical absorption. Based on information acquired in the literature search, PNL recommends that follow-on activities focus on ISFET devices and a fiber optic evanescent sensor with a colormetric indicator. The ISFET and fiber optic evanescent sensor are inherently microminiature and capable of in situ measurements. Further, both techniques have been demonstrated selective to the ammonium ion (NH{sub 4}{sup +}). The primary issue remaining is how to make the sensors sufficiently corrosion-resistant to be useful in practice.

  7. Evaluation of new concepts for in situ vitrification: Power system, melt insulation, and off-gas containment

    International Nuclear Information System (INIS)

    Luey, J.; Powell, T.D.; Heath, W.O.; Richardson, R.L.

    1992-07-01

    In situ vitrification (ISV) is a thermal process that converts contaminated soil into a highly leach-resistant material resembling natural obsidian. The ISV process was developed by the Pacific Northwest Laboratory (PNL)(a) for the US Department of Energy (DOE) to treat soils contaminated with transuranics. Since 1980, ISV has grown from a concept to an innovative technology through bench-, engineering-, intermediate-, and full-scale tests. Efforts by PNL have developed ISV into a technology considered available for limited deployment to remediate contaminated soil. The technology has been transferred to a licensee for commercial application. In September 1991, PNL conducted an operational acceptance test (OAT) of the modified engineering-scale unit. The OAT provided an opportunity to conduct proof-of-principle testing of new concepts for ISV technology. This additional testing was permitted since it was determined that testing of these new concepts would have no impact on the OAT objective. In discussing the proof-of-principle portion of the engineering-scale test, this report presents conclusions from this work and also describes the conceptual bases of the tested concepts, the engineering-scale test equipment and setup, and test results

  8. Unigene BLAST: CBRC-GGAL-09-0012 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-GGAL-09-0012 gnl|UG|Gga#S6698203 pnl1s.pk003.f8 chicken liver cDNA library Gallus gallus cDNA clone pnl...1s.pk003.f8 5' similar to histidine-rich glycoprotein - bovine (fragments), mRNA sequence /clone=pnl

  9. Stochastic Lanchester Air-to-Air Campaign Model: Model Description and Users Guides

    Science.gov (United States)

    2009-01-01

    state PBW = Probability of Blue win PRW = Probability of Red win PNL = Probability of no loss Px = Probability of event x Qx = (1-Px) Probability...probabilities are PNL , PBW, and PRW.4 To infer KRR ≡ kb/kr, we may evaluate P11 as equal to PNL , and then solve [ ] [ 1111BW10 P1KRR1 KRRP1 k ] rkb kbPP...Eq. 2-10] for KRR. 4 One may choose to divide the Pd − Pk probabilities PBW, PRW, and PNL by 1

  10. Sampling and analysis plan for ORNL filter press cake waste from the Liquid and Gaseous Waste Operations Department

    International Nuclear Information System (INIS)

    Bartling, M.H.; Bayne, C.K.; Cunningham, G.R.

    1994-09-01

    This document defines the sampling and analytical procedures needed for the initial characterization of the filter press cake waste from the Process Waste Treatment Plant (PWTP) at the Oak Ridge National Laboratory (ORNL). It is anticipated that revisions to this document will occur as operating experience and sample results suggest appropriate changes be made. Application of this document will be controlled through the ORNL Waste Management and Remedial Action Division. The sampling strategy is designed to ensure that the samples collected present an accurate representation of the waste process stream. Using process knowledge and preliminary radiological activity screens, the filter press cake waste is known to contain radionuclides. Chemical characterization under the premise of this sampling and analysis plan will provide information regarding possible treatments and ultimately, disposal of filter press cake waste at an offsite location. The sampling strategy and analyses requested are based on the K-25 waste acceptance criteria and the Nevada Test Site Defense Waste Acceptance Criteria, Certification, and Transfer Requirements [2, NVO-325, Rev. 1]. The sampling strategy will demonstrate that for the filter press cake waste there is (1) an absence of RCRA and PCBs wastes, (2) an absence of transuranic (TRU) wastes, and (3) a quantifiable amount of radionuclide activity

  11. Genetic and molecular analyses of Escherichia coli N-acetylneuraminate lyase gene.

    OpenAIRE

    Kawakami, B; Kudo, T; Narahashi, Y; Horikoshi, K

    1986-01-01

    Two plasmids containing the N-acetylneuraminate lyase (NALase) gene (nanA) of Escherichia coli, pNL1 and pNL4, were constructed. Immunoprecipitation analysis indicated that the 35,000-dalton protein encoded in pNL4 was NALase. The synthesis of NALase in E. coli carrying these plasmids was constitutive.

  12. Final irradiation and postirradiation data from the NRC/PNL instrumented assembly IFA-432

    International Nuclear Information System (INIS)

    Lanning, D.D.; Bradley, E.R.

    1986-02-01

    The instrumented six-rod test assembly IFA-432, sponsored by USNRC, operated in the Halden Reactor from December 1975 to May 1984, with surviving fuel thermocouples, neutron detectors and pressure transducers. Peak burnups of 46 MWd/kgM were achieved. Interim destructive examination data were obtained at peak burnups of 24 and 34 MWd/kgM. This paper presents a synopsis of the irradiation histories and postirradiation examination data for the high burnup rods. The postirradiation condition of the rods correlates well with their individual design parameters and operating conditions

  13. Low gravity fluid-thermal experiments

    International Nuclear Information System (INIS)

    Krotiuk, W.J.; Cuta, J.M.

    1987-06-01

    Pacific Northwest Laboratory (PNL) is the lead laboratory for the thermal-hydraulic research in the US Department of Energy Multimegawatt Space Nuclear Power Program. PNL must provide the tools necessary to analyze proposed space reactor concepts, which include single- and two-phase alkali metal and gas-cooled designs. PNL has divided its activities for this task into three basic areas: computer code development, thermal-hydraulic modeling, and experimentation. The subject of this paper is the low-gravity experimental program currently underway at PNL in support of the MMW Program

  14. Hanford defense waste studies

    International Nuclear Information System (INIS)

    Napier, B.A.; Zimmerman, M.G.; Soldat, J.K.

    1981-01-01

    PNL is assisting Rockwell Hanford Operations to prepare a programmatic environmental impact statement for the management of Hanford defense nuclear waste. The Ecological Sciences Department is leading the task of calculation of public radiation doses from a large matrix of potential routine and accidental releases of radionuclides to the environment

  15. Uniform Sampling Table Method and its Applications II--Evaluating the Uniform Sampling by Experiment.

    Science.gov (United States)

    Chen, Yibin; Chen, Jiaxi; Chen, Xuan; Wang, Min; Wang, Wei

    2015-01-01

    A new method of uniform sampling is evaluated in this paper. The items and indexes were adopted to evaluate the rationality of the uniform sampling. The evaluation items included convenience of operation, uniformity of sampling site distribution, and accuracy and precision of measured results. The evaluation indexes included operational complexity, occupation rate of sampling site in a row and column, relative accuracy of pill weight, and relative deviation of pill weight. They were obtained from three kinds of drugs with different shape and size by four kinds of sampling methods. Gray correlation analysis was adopted to make the comprehensive evaluation by comparing it with the standard method. The experimental results showed that the convenience of uniform sampling method was 1 (100%), odds ratio of occupation rate in a row and column was infinity, relative accuracy was 99.50-99.89%, reproducibility RSD was 0.45-0.89%, and weighted incidence degree exceeded the standard method. Hence, the uniform sampling method was easy to operate, and the selected samples were distributed uniformly. The experimental results demonstrated that the uniform sampling method has good accuracy and reproducibility, which can be put into use in drugs analysis.

  16. Recommended operating procedure number 56: Collection of gaseous grab samples from combustion sources for nitrous oxide measurement. Final report, Jan-Dec 91

    International Nuclear Information System (INIS)

    Ryan, J.V.; Karns, S.A.

    1992-07-01

    The document is a recommended operating procedure (ROP), prepared for use in research activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). The procedure applies to the collection of gaseous grab samples from fossil fuel combustion sources for subsequent analysis of nitrous oxide. The procedure details only the grab sampling methodology and associated equipment

  17. Primary Report of Totally Tubeless Percutaneous Nephrolithotomy Despite Pelvi-calyceal Perforations.

    Science.gov (United States)

    Aghamir, Seyed Mohammad Kazem; Salavati, Alborz; Hamidi, Morteza; FallahNejad, Asghar

    2017-07-02

    Nephrostomy tube insertion and/or a ureteral stent placement is advised when pelvi-calyceal perforations are encountered during percutaneous nephrolithotomy (PNL) nevertheless totally tubeless PNL is a possible exit strategy in percutaneous renal surgery therefore case series on the short term clinical outcomes of noninvasive management of iatrogenic pelvicalyceal perforations encountered during PNL is presented. During retrospective analysis of 1271 PNL procedures, 25 incidents of accidental ureteral catheter/ jj stent dislodgement during first 24 post-operative hours were identified in patient who had pelvi calyceal perforations and had no nephrostomy tube (tubeless). Thirteen patients could not be re-stented nor a nephrostomytube could have been placed for them mainly due to patient refusal or comorbid conditions. The main outcome was rate of successful noninvasive management. Eighteen Patients bearing mucosal tears (grade I trauma) or visible peri-pelvic fat (grade II) successfully recovered without need for ureteral stenting or nephrostomy (72.0%). In seven (28.0%) cases of extension of the perforation into the peri-pelvic fat (grade III), either nephrostomy insertion or JJ stenting was needed for resolution of fever and urinoma. The major limitation was the necessity to exclude patients and manage them in the standard fashion according to clinical guidelines. Iatrogenic perforations of the collecting system are quite diverse in terms of severity that result in different natural histories and not all might need urinary diversion via nephrostomy or ureteral stenting.Low grade perforations may be successfully managed in totally tubeless fashion nevertheless further prospective investigations seem warranted.

  18. A novel dosimeter for measuring the amount of radiation exposure of surgeons during percutaneous nephrolithotomy: Instadose™

    Science.gov (United States)

    Yuruk, Emrah; Gureser, Gokhan; Tuken, Murat; Ertas, Kasim

    2016-01-01

    Introduction The aim of this study was to demonstrate the efficacy of Instadose™, a novel dosimeter designed for radiation workers to provide a measurement of the radiation dose at any time from any computer; to determine the amount of radiation exposure during percutaneous nephrolithotomy (PNL); and to evaluate the factors that affect the amount of radiation exposed. Material and methods Two experienced surgeons wore Instadose™ on the outer part of their lead aprons during the PNL procedures performed between December 2013 and July 2014. Patient demographics and stone characteristics were noted. Factors affecting radiation dose were determined. Fluoroscopic screening time was compared with the amount of radiation in order to validate the measurements of Instadose™. Results Overall, 51 patients with a mean age of 43.41 ±18.58 (range 1–75) years were enrolled. Male to female ratio was 35/16. The amount of radiation was greater than 0.01mSv in only 19 (37.25%) cases. Stone location complexity (p = 0.380), dilation type (p = 0.584), stone size (p = 0.565), dilation size (p = 0.891) and access number (p = 0.268) were not associated with increased radiation exposure. Instadose™ measurements were correlated with fluoroscopic screening time (r = 0.519, p = 0.001). Conclusions Instadose™ is a useful tool for the measurement of radiation exposure during PNL. The advantage of measuring the amount of radiation exposure after each PNL operation is that it may aid urologists in taking appropriate precautions to minimize the risk of radiation related complications. PMID:27551558

  19. Statistical sampling plans

    International Nuclear Information System (INIS)

    Jaech, J.L.

    1984-01-01

    In auditing and in inspection, one selects a number of items by some set of procedures and performs measurements which are compared with the operator's values. This session considers the problem of how to select the samples to be measured, and what kinds of measurements to make. In the inspection situation, the ultimate aim is to independently verify the operator's material balance. The effectiveness of the sample plan in achieving this objective is briefly considered. The discussion focuses on the model plant

  20. Performance assessment of the proposed Monitored Retrievable Storage Facility

    International Nuclear Information System (INIS)

    Chockie, A.D.; Hostick, C.J.; Winter, C.

    1986-02-01

    Pacific Northwest laboratory (PNL) has completed a performance evaluation of the proposed monitored retrievable storage (MRS) facility. This study was undertaken as part of the Department of Energy MRS Program at PNL. The objective of the performance evaluation was to determine whether the conceptual MRS facility would be able to process spent fuel at the specified design rate of 3600 metric tons of uranium (MTU) per year. The performance of the proposed facility was assessed using the computer model COMPACT (Computer Optimization of Processing and Cask Transport) to simulate facility operations. The COMPACT model consisted of three application models each of which addressed a different aspect of the facility's operation: MRS/waste transportation interface; cask handling capability; and disassembly/consolidation (hot cell) operations. Our conclusions, based on the assessment of design criteria for the proposed facility, are as follows: Facilities and equipment throughout the facility have capability beyond the 3600 MTU/y design requirement. This added capability provides a reserve to compensate for unexpected perturbations in shipping or handling of the spent fuel. Calculations indicate that the facility's maximum maintainable processing capability is approximately 4800 MTU/y

  1. Transportation ALARA analysis for a nuclear waste management system

    International Nuclear Information System (INIS)

    McNair, G. W.; Schneider, K.; Smith, R.I.; Ross, W.; Faletti, D.

    1988-01-01

    In planning for implementation of a safe and cost-effective transportation system, the Department of Energy (DOE) commissioned the Pacific Northwest Laboratory (PNL) to develop estimates of the radiation doses, both public and occupational, that would result from operation of a system postulated using current designs and practices. From that evaluation, PNL identified activities/operations that result in relatively high doses, proposed conceptual alternatives that would effectively reduce such exposures, and evaluated the cost-effectiveness of such alternatives. This study contains an analysis of routine operations and estimates of the public and worker radiation doses that would occur in a postulated generic reference spent fuel transportation system using both truck and rail modes. Total risks are not estimated (i.e., consideration of nonradiological or accident risks that will be the subject of future studies in the transportation systems study plan 9TSSP) are not included). The system encompasses spent fuel loading at the reactor, transportation of the fuel to and from a receiving and handling facility and unloading of the fuel at a repository. The analysis provides cost/dose trade-offs of the postulated reference system as well as selected potential alternatives to the transportation system

  2. Gas-driven pump for ground-water samples

    Science.gov (United States)

    Signor, Donald C.

    1978-01-01

    Observation wells installed for artificial-recharge research and other wells used in different ground-water programs are frequently cased with small-diameter steel pipe. To obtain samples from these small-diameter wells in order to monitor water quality, and to calibrate solute-transport models, a small-diameter pump with unique operating characteristics is required that causes a minimum alternation of samples during field sampling. A small-diameter gas-driven pump was designed and built to obtain water samples from wells of two-inch diameter or larger. The pump is a double-piston type with the following characteristics: (1) The water sample is isolated from the operating gas, (2) no source of electricity is ncessary, (3) operation is continuous, (4) use of compressed gas is efficient, and (5) operation is reliable over extended periods of time. Principles of operation, actual operation techniques, gas-use analyses and operating experience are described. Complete working drawings and a component list are included. Recent modifications and pump construction for high-pressure applications also are described. (Woodard-USGS)

  3. Is tubeless percutaneous nephrolithotomy a feasible technique for the treatment of staghorn calculi?

    Science.gov (United States)

    Lee, Sang Cheol; Kim, Chang Hee; Kim, Kwang Taek; Kim, Tae Beom; Kim, Khae Hawn; Jung, Han; Yoon, Sang Jin; Oh, Jin Kyu

    2013-10-01

    Tubeless percutaneous nephrolithotomy (PNL) remains a challenging technique for the surgical treatment of staghorn renal calculi. Our study was designed to compare surgical outcomes between conventional and tubeless PNL. We retrospectively enrolled consecutive patients who underwent conventional or tubeless PNL under general anesthesia performed by a single surgeon (H.J.) for the treatment of staghorn calculi between 2003 and 2012. All patients were divided into two groups: group 1 included patients who underwent conventional PNL and group 2 included patients who were managed by tubeless PNL for the treatment of staghorn calculi. Preoperative and postoperative parameters were analyzed between the two groups, including age, stone burden, complications, any interventions, and duration of hospital stay. A total of 165 patients (group 1, 106; group 2, 59) were enrolled in the study. No significant differences in age, sex, body mass index, or stone laterality were observed between the two groups. The mean stone burdens (±standard deviation) of group 1 and group 2 were 633.6 (±667.4) and 529.9 (±362.8), respectively (p=0.271). The postoperative stone-free clearance rate was higher in group 2 (78.0%) than in group 1 (69.8%); however, the difference was not clinically significant (p=0.127). In addition, no significant differences in postoperative complications, including fever, bleeding, infection, or additional interventions, were observed between the two groups. Our results demonstrated that tubeless PNL has the same effectiveness and safety as conventional PNL in the treatment of staghorn calculi. Tubeless PNL may be feasible for managing renal staghorn calculi.

  4. Pacific Northwest Laboratory annual report for 1980 to the DOE Assistant Secretary for Environment. Part 5. Environmental assessment, control, health and safety

    International Nuclear Information System (INIS)

    Baalman, R.W.; Hays, I.D.

    1981-02-01

    Pacific Northwest Laboratory's (PNL) 1980 annual report to the DOE Assistant Secretary for Environment describes research in environment, health, and safety conducted during fiscal year 1980. Part 5 includes technology assessments for natural gas, enhanced oil recovery, oil shale, uranium mining, magnetic fusion energy, solar energy, uranium enrichment and industrial energy utilization; regional analysis studies of environmental transport and community impacts; environmental and safety engineering for LNG, oil spills, LPG, shale oil waste waters, geothermal liquid waste disposal, compressed air energy storage, and nuclear/fusion fuel cycles; operational and environmental safety studies of decommissioning, environmental monitoring, personnel dosimetry, and analysis of criticality safety; health physics studies; and epidemiological studies. Also included are an author index, organization of PNL charts and distribution lists of the annual report, along with lists of presentations and publications

  5. Equipment experience in a radioactive LFCM [liquid-fed ceramic melter] vitrification facility

    International Nuclear Information System (INIS)

    Holton, L.K. Jr.; Dierks, R.D.; Sevigny, G.J.; Goles, R.W.; Surma, J.E.; Thomas, N.M.

    1986-11-01

    Since October 1984, the Pacific Northwest Laboratory (PNL) has operated a pilot-scale radioactive liquid-fed ceramic melter (RLFCM) vitrification process in shielded manipulator hot cells. This vitrification facility is being operated for the Department of Energy (DOE) to remotely test vitrification equipment components in a radioactive environment and to develop design and operation data that can be applied to production-scale projects. This paper summarizes equipment and process experience obtained from the operations of equipment systems for waste feeding, waste vitrification, canister filling, canister handling, and vitrification off-gas treatment

  6. Improving the Current DHS Capabilities Framework

    Science.gov (United States)

    2008-09-01

    Laboratories ( PNL ) to establish the standards for the NIMS initiative. This entire situation creates another set of inconsistencies in criteria for...www.hsaj.org/?fullarticle=1.2.2, (accessed June 12, 2007), 8. 24 setting agencies: NFPA, PNL , American National Standards Institute (ANSI), and...with Pacific Northwest Laboratory ( PNL ) to develop the NIC standards. The Incident Management Standards Working Group (IMSWG) was established

  7. Optimization of the Army’s Fast Neutron Moderator for Radiography

    Science.gov (United States)

    2013-02-26

    TECHNOLOGY DEVELOPMENTS 13 PNL Generator / Moderator Design 13 CONCLUSIONS 15 REFERENCES 16 LIST OF SYMBOLS, ABBREVIATIONS...and x-ray image 12 Figure 6: Second half comparison of neutron, processed, and x-ray image 13 Figure 7: The initial setup of the PNL neutron...reactor facility; for example, muntions and weapon systems that contain energetic materials. TECHNOLOGY DEVELOPMENTS: PNL Generator / Moderator

  8. Monitored Retrievable Storage conceptual system study: metal storage casks

    International Nuclear Information System (INIS)

    Unterzuber, R.; Cross, T.E.; Krasicki, B.R.

    1983-08-01

    A description of the metal cask storage facility concept is presented with the operations required to handle the spent fuel or high-level wastes and transuranic wastes. A generic Receiving and Handling Facility, provided by PNL, has been used for this study. Modifications to the storage delivery side of the handling facility, necessary to couple the Receiving and Handling Facility with the storage facility, are described. The equipment and support facilities needed for the storage facility are also described. Two separate storage facilities are presented herein: one for all spent fuel storage, and one for storage of high-level waste (HLW) and transuranic waste (TRU). Each facility is described for the capacities and rates defined by PNL in the Concept Technical Performance Criteria and Base Assumptions (see Table 1.3-1). Estimates of costs and time-distributions of expenditures have been developed to construct, operate, and decommission the conceptual MRS facilities in mid-1983 dollars, for the base cases given using the cost categories and percentages provided by PNL. Cost estimates and time-distributions of expenditures have also been developed to expand the facility throughput rate from 1800 MTU to 3000 MTU, and to expand the facility storage capacity from 15,000 MTU to 72,00 MTU. The life cycle cost of the facility for the bounding cases of all spent fuel and all HLW and TRU, using the time-distributions of costs developed above and assuming a two percent per year discount rate, are also presented. 3 references, 16 figures, 18 tables

  9. Aquatic invertebrate sampling at selected outfalls in Operable Unit 1082; Technical areas 9, 11, 16 and 22

    Energy Technology Data Exchange (ETDEWEB)

    Cross, S.

    1995-09-01

    The Ecological Studies Team (EST) of ESH-20 at Los Alamos National Laboratory conducted preliminary aquatic sampling at outfalls within Operable Unit 1082 and nearby natural waterways. Eleven outfalls were sampled a total of eighteen times. Three natural waterways (upper Pajarito Canyon, Starmer`s Gulch, and Bulldog Spring) in the vicinity were sampled a total of six times. At most sites, EST recorded hydrological condition, physico-chemical parameters, wildlife uses, and vegetation. At each outfall with water and each natural waterway, EST collected an aquatic invertebrate sample which was analyzed by taxa composition, Wilhm`s biodiversity index, the community tolerance quotient (CTQ), and density. The physico-chemical parameters at most outfalls and natural waterways fell within the normal range of natural waters in the area. However, the outfalls are characterized by low biodiversity and severely stressed communities composed of a restricted number of taxa. The habitat at the other outfalls could probably support well-developed aquatic communities if sufficient water was available. At present, the hydrology at these outfalls is too slight and/or sporadic to support such a community in the foreseeable future. In contrast to the outfalls, the natural waterways of the area had greater densities of aquatic invertebrates, higher biodiversities, and lower CTQs.

  10. Analysis of material removed from UCLA tokamaks Microtor and Macrotor

    International Nuclear Information System (INIS)

    Baer, D.R.; Thomas, M.T.; Taylor, R.J.

    1979-02-01

    This paper reports a first effort to examine the surface of the UCLA tokamaks, Microtor and Macrotor, by analyzing samples that have been exposed to plasma discharge and cleaning for long periods. The samples were sent to the Surface Science Section at the Pacific Northwest Laboratory (PNL). There, Auger electron spectrometry and sputter profile techniques were used to examine the samples, which had been handled in atmospheric conditions after being removed from the tokamak

  11. The Japanese Society of Pathology Guidelines on the handling of pathological tissue samples for genomic research: Standard operating procedures based on empirical analyses.

    Science.gov (United States)

    Kanai, Yae; Nishihara, Hiroshi; Miyagi, Yohei; Tsuruyama, Tatsuhiro; Taguchi, Kenichi; Katoh, Hiroto; Takeuchi, Tomoyo; Gotoh, Masahiro; Kuramoto, Junko; Arai, Eri; Ojima, Hidenori; Shibuya, Ayako; Yoshida, Teruhiko; Akahane, Toshiaki; Kasajima, Rika; Morita, Kei-Ichi; Inazawa, Johji; Sasaki, Takeshi; Fukayama, Masashi; Oda, Yoshinao

    2018-02-01

    Genome research using appropriately collected pathological tissue samples is expected to yield breakthroughs in the development of biomarkers and identification of therapeutic targets for diseases such as cancers. In this connection, the Japanese Society of Pathology (JSP) has developed "The JSP Guidelines on the Handling of Pathological Tissue Samples for Genomic Research" based on an abundance of data from empirical analyses of tissue samples collected and stored under various conditions. Tissue samples should be collected from appropriate sites within surgically resected specimens, without disturbing the features on which pathological diagnosis is based, while avoiding bleeding or necrotic foci. They should be collected as soon as possible after resection: at the latest within about 3 h of storage at 4°C. Preferably, snap-frozen samples should be stored in liquid nitrogen (about -180°C) until use. When intending to use genomic DNA extracted from formalin-fixed paraffin-embedded tissue, 10% neutral buffered formalin should be used. Insufficient fixation and overfixation must both be avoided. We hope that pathologists, clinicians, clinical laboratory technicians and biobank operators will come to master the handling of pathological tissue samples based on the standard operating procedures in these Guidelines to yield results that will assist in the realization of genomic medicine. © 2018 The Authors. Pathology International published by Japanese Society of Pathology and John Wiley & Sons Australia, Ltd.

  12. Evaluation of stone volume distribution in renal collecting system as a predictor of stone-free rate after percutaneous nephrolithotomy: a retrospective single-center study.

    Science.gov (United States)

    Atalay, Hasan Anıl; Canat, Lutfi; Bayraktarlı, Recep; Alkan, Ilter; Can, Osman; Altunrende, Fatih

    2017-06-23

    We analyzed our stone-free rates of PNL with regard to stone burden and its ratio to the renal collecting system volume. Data of 164 patients who underwent PNL were analyzed retrospectively. Volume segmentation of renal collecting system and stones were done using 3D segmentation software with the images obtained from CT data. Analyzed stone volume (ASV) and renal collecting system volume (RCSV) were measured and the ASV-to-RCSV ratio was calculated after the creation of a 3D surface volume rendering of renal stones and the collecting system. Univariate and multivariate statistical analyses were performed to determine factors affecting stone-free rates; also we assessed the predictive accuracy of the ASV-to-RCSV ratio using the receiving operating curve (ROC) and AUC. The stone-free rate of PNL monotherapy was 53% (164 procedures).The ASV-to-RCSV ratio and calyx number with stones were the most influential predictors of stone-free status (OR 4.15, 95% CI 2.24-7.24, renal collecting system, which is calculated using the 3D volume segmentation method, is a significant determinant of the stone-free rate before PCNL surgery. It could be used as a single guide variable by the clinician before renal stone surgery to predict extra requirements for stone clearance.

  13. Summary of literature review of risk communication: Hanford Environmental Dose Reconstruction Project

    International Nuclear Information System (INIS)

    Byram, S.J.

    1991-05-01

    The Hanford Environmental Dose Reconstruction (HEDR) Project will estimate radiation exposures people may have received from radioactive materials released during past operations at the Department of Energy's Hanford Site near Richland, Washington. The project is being conducted by Pacific Northwest Laboratory (PNL) under the direction of an independent Technical Steering Panel (TSP). The Centers for Disease Control (CDC) will use HEDR dose estimates in studies to investigate a potential link between thyroid disease and historical Hanford emissions. The HEDR Project was initiated to address public concerns about the possible health impacts from past releases of radioactive materials from Hanford. The TSP recognized early in the project that special mechanisms would be required to communicate effectively to the many different concerned audiences. To identify and develop these mechanisms, the TSP issued Directive 89-7 to PNL in May 1989. The TSP directed PNL to examine methods to communicate the causes and effects of uncertainties in the dose estimates. A literature review was conducted as the first activity in response to the TSP's directive. This report presents the results of the literature review. The objective of the literature review was to identify ''key principles'' that could be applied to develop communications strategies for the project. 26 refs., 6 figs

  14. Russian RBMK reactor design information

    International Nuclear Information System (INIS)

    1993-11-01

    This document concerns the systems, design, and operations of the graphite-moderated, boiling, water-cooled, channel-type (RBMK) reactors located in the former Soviet Union (FSU). The Russian Academy of Sciences Nuclear Safety Institute (NSI) in Moscow, Russia, researched specific technical questions that were formulated by the Pacific Northwest Laboratory (PNL) and provided detailed technical answers to those questions. The Russian response was prepared in English by NSI in a question-and-answer format. This report presents the results of that technical exchange in the context they were received from the NSI organization. Pacific Northwest Laboratory is generating this document to support the US Department of Energy (DOE) community in responding to requests from FSU states, which are seeking Western technological and financial assistance to improve the safety systems of the Russian-designed reactors. This report expands upon information that was previously available to the United States through bilateral information exchanges, international nuclear society meetings, International Atomic Energy Agency (IAEA) reactor safety programs, and Research and Development Institute of Power Engineering (RDIPE) reports. The response to the PNL questions have not been edited or reviewed for technical consistency or accuracy by PNL staff or other US organizations, but are provided for use by the DOE community in the form they were received

  15. Sampling procedures and tables

    International Nuclear Information System (INIS)

    Franzkowski, R.

    1980-01-01

    Characteristics, defects, defectives - Sampling by attributes and by variables - Sample versus population - Frequency distributions for the number of defectives or the number of defects in the sample - Operating characteristic curve, producer's risk, consumer's risk - Acceptable quality level AQL - Average outgoing quality AOQ - Standard ISQ 2859 - Fundamentals of sampling by variables for fraction defective. (RW)

  16. Initial Steps Toward Next-Generation, Waveform-Based, Three-Dimensional Models and Metrics to Improve Nuclear Explosion Monitoring in the Middle East

    Science.gov (United States)

    2008-09-30

    propagation effects by splitting apart the longer period surface waves from the shorter period, depth-sensitive Pnl waves. Problematic, or high-error... Pnl waves. Problematic, or high-error, stations and paths were further analyzed to identify systematic errors with unknown sensor responses and...frequency Pnl components and slower, longer period surface waves. All cut windows are fit simultaneously, allowing equal weighting of phases that may be

  17. Reactor water sampling device

    International Nuclear Information System (INIS)

    Sakamaki, Kazuo.

    1992-01-01

    The present invention concerns a reactor water sampling device for sampling reactor water in an in-core monitor (neutron measuring tube) housing in a BWR type reactor. The upper end portion of a drain pipe of the reactor water sampling device is attached detachably to an in-core monitor flange. A push-up rod is inserted in the drain pipe vertically movably. A sampling vessel and a vacuum pump are connected to the lower end of the drain pipe. A vacuum pump is operated to depressurize the inside of the device and move the push-up rod upwardly. Reactor water in the in-core monitor housing flows between the drain pipe and the push-up rod and flows into the sampling vessel. With such a constitution, reactor water in the in-core monitor housing can be sampled rapidly with neither opening the lid of the reactor pressure vessel nor being in contact with air. Accordingly, operator's exposure dose can be reduced. (I.N.)

  18. C-018H Pre-Operational Baseline Sampling Plan

    International Nuclear Information System (INIS)

    Guzek, S.J.

    1993-01-01

    The objective of this task is to field characterize and sample the soil at selected locations along the proposed effluent line routes for Project C-018H. The overall purpose of this effort is to meet the proposed plan to discontinue the disposal of contaminated liquids into the Hanford soil column as described by DOE (1987). Detailed information describing proposed transport pipeline route and associated Kaiser Engineers Hanford Company (KEH) preliminary drawings (H288746...755) all inclusive, have been prepared by KEH (1992). The information developed from field monitoring and sampling will be utilized to characterize surface and subsurface soil along the proposed C-018H effluent pipeline and it's associated facilities. Potentially existing contaminant levels may be encountered therefore, soil characterization will provide a construction preoperational baseline reference, develop personnel safety requirements, and determine the need for any changes in the proposed routes prior to construction of the pipeline

  19. Percutaneous nephrolithotomy in patients with a solitary kidney

    Directory of Open Access Journals (Sweden)

    Tufan Süelözgen

    2014-12-01

    Full Text Available Material and method: The results of percutaneous nephrolithotomy applied to 716 patients in our clinic between January 2008 and January 2014 were retrospectively evaluated. Age, gender, urinary calculi size (mm2, urinary calculi localization, ESWL history, operation duration (min, fluoroscopy duration (sec, access type, reason of solitary kidney, hemoglobin drawdown (g/dl and operation success of the patients with a solitary kidney were recorded. The patients having no preoperative and postoperative non contrast abdominal tomography were excluded from the study. Results: Fifteen of nineteen patients (79% were men and 4 of them (21% were women. The average age of the patients was 42.52 ± 16.72 (14-72. Ten patients had anatomical solitary kidney and nine patients had physiological solitary kidney. In fact counter kidney was non functional in 9 patients (47% whereas there was agenesis in 2 (11% and outcome of nephrectomy in 8 (42% patients. In our study, presence of residual stone less than 4 mm at 1st month postoperative non contrast abdominal tomography was accepted as a successful result and accordingly our success rate was detected as 84%. Mean urinary calculi size was 405 ± 252.9 mm2; urinary calculi localization was pelvic, lower pole, upper-middle pole, middle-lower pole and staghorn in 11 (58%, 4 (21%, 1 (5%, 1 (5% and 1 (5% patients, respectively; previous ESWL history was 16%; operation duration was 55.47-± 28.1 min and fluoroscopy duration 131.10 ± 87.6 sec; access type was subcostal in 79%, supracostal in 10.5% and multiple in 10.5%; hemoglobin drawdown was 1.75 ± 0.97 mg/dl. Conclusions: PNL can be effectively and safely administered for the treatment of solitary kidney. In the treatment of large urinary calculi in patients with a solitary kidney, PNL has some advantages such as short surgery duration, less complication, acceptable hemoglobin drawdown and high success rates. According to our study, PNL operation in patients with a

  20. Special nuclear material inventory sampling plans

    International Nuclear Information System (INIS)

    Vaccaro, H.; Goldman, A.

    1987-01-01

    Since their introduction in 1942, sampling inspection procedures have been common quality assurance practice. The U.S. Department of Energy (DOE) supports such sampling of special nuclear materials inventories. The DOE Order 5630.7 states, Operations Offices may develop and use statistically valid sampling plans appropriate for their site-specific needs. The benefits for nuclear facilities operations include reduced worker exposure and reduced work load. Improved procedures have been developed for obtaining statistically valid sampling plans that maximize these benefits. The double sampling concept is described and the resulting sample sizes for double sample plans are compared with other plans. An algorithm is given for finding optimal double sampling plans that assist in choosing the appropriate detection and false alarm probabilities for various sampling plans

  1. Time/motion observations and dose analysis of reactor loading, transportation, and dry unloading of an overweight truck spent fuel shipment

    International Nuclear Information System (INIS)

    Hostick, C.J.; Lavender, J.C.; Wakeman, B.H.

    1992-04-01

    This document presents observed activity durations and radiation dose analyses for an overweight truck shipment of pressurized water reactor (PWR) spent fuel from the Surry Power Station in Virginia to the Idaho National Engineering Laboratory. The shipment consisted of a TN-8L shipping cask carrying three 9-year-old PWR spent fuel assemblies. Handling times and dose analyses for at-reactor activities were completed by Virginia Electric and Power Company (Virginia Power) personnel. Observations of in-transit and unloading activities were made by Pacific Northwest Laboratory (PNL) personnel, who followed the shipment for approximately 2800 miles and observed cask unloading activities. In-transit dose estimates were calculated using dose rate maps provided by Virginia Power for a fully loaded TN-8L shipping cask. The dose analysis for the cask unloading operations is based on the observations of PNL personnel

  2. Research on geothermal chemistry and advanced instrumentation

    Science.gov (United States)

    Robertus, R. J.; Shannon, D. W.; Sullivan, R. G.; Kindle, C. H.; Pool, K. H.

    1985-09-01

    Research at the Pacific Northwest Laboratory (PNL) focuses on long-term geothermal power plant reliability. Past work concentrated on development of continuous high-temperature probes for monitoring process variables. PNL also completed a comprehensive handbook of brine treatment processes as they relate to injection well longevity. A recently completed study analyzed corrosion in the hydrocarbon system of a binary cycle plant. Over the two-year monitoring period, corrosion rates were less than 1 MPY in any part of the hydrocarbon system. The system was kept completely dry so the rates seem reasonable. Present projects include: (1) determination of gas breakout conditions at the Herber Binary Demonstration Plant operated by San Diego Gas and Electric Company; (2) generation of water mixing solubility data; (3) installation of prototype leak detectors at the Herber Plant; and (4) evaluation of state-of-the-art particle counters.

  3. Pacific Northwest Laboratory annual report for 1980 to the DOE Assistant Secretary for Environment. Part 5. Environmental assessment, control, health and safety

    Energy Technology Data Exchange (ETDEWEB)

    Baalman, R.W.; Hays, I.D. (eds.)

    1981-02-01

    Pacific Northwest Laboratory's (PNL) 1980 annual report to the DOE Assistant Secretary for Environment describes research in environment, health, and safety conducted during fiscal year 1980. Part 5 includes technology assessments for natural gas, enhanced oil recovery, oil shale, uranium mining, magnetic fusion energy, solar energy, uranium enrichment and industrial energy utilization; regional analysis studies of environmental transport and community impacts; environmental and safety engineering for LNG, oil spills, LPG, shale oil waste waters, geothermal liquid waste disposal, compressed air energy storage, and nuclear/fusion fuel cycles; operational and environmental safety studies of decommissioning, environmental monitoring, personnel dosimetry, and analysis of criticality safety; health physics studies; and epidemiological studies. Also included are an author index, organization of PNL charts and distribution lists of the annual report, along with lists of presentations and publications. (DLS)

  4. A safety equipment list for rotary mode core sampling systems operation in single shell flammable gas tanks

    International Nuclear Information System (INIS)

    SMALLEY, J.L.

    1999-01-01

    This document identifies all interim safety equipment to be used for rotary mode core sampling of single-shell flammable gas tanks utilizing Rotary Mode Core Sampling systems (RMCS). This document provides the safety equipment for RMCS trucks HO-68K-4600, HO-68K-4647, trucks three and four respectively, and associated equipment. It is not intended to replace or supersede WHC-SD-WM-SEL-023, (Kelly 1991), or WHC-SD-WM-SEL-032, (Corbett 1994), which classifies 80-68K-4344 and HO-68K-4345 respectively. The term ''safety equipment'' refers to safety class (SC) and safety significant (SS) equipment, where equipment refers to structures, systems and components (SSC's). The identification of safety equipment in this document is based on the credited design safety features and analysis contained in the Authorization Basis (AB) for rotary mode core sampling operations in single-shell flammable gas tanks. This is an interim safety classification since the AB is interim. This document will be updated to reflect the final RMCS equipment safety classification designations upon completion of a final AB which will be implemented with the release of the Final Safety Analysis Report (FSAR)

  5. Propositional interval neighborhood logics: Expressiveness, decidability, and undecidable extensions

    DEFF Research Database (Denmark)

    Bresolin, Davide; Goranko, Valentin; Montanari, Angelo

    2009-01-01

    In this paper, we investigate the expressiveness of the variety of propositional interval neighborhood logics (PNL), we establish their decidability on linearly ordered domains and some important subclasses, and we prove the undecidability of a number of extensions of PNL with additional modalities...... over interval relations. All together, we show that PNL form a quite expressive and nearly maximal decidable fragment of Halpern–Shoham’s interval logic HS....

  6. Advanced Waveform Simulation for Seismic Monitoring

    Science.gov (United States)

    2008-09-01

    velocity model. The method separates the main arrivals of the regional waveform into 5 windows: Pnl (vertical and radial components), Rayleigh (vertical and...ranges out to 10°, including extensive observations of crustal thinning and thickening and various Pnl complexities. Broadband modeling in 1D, 2D...existing models perform in predicting the various regional phases, Rayleigh waves, Love waves, and Pnl waves. Previous events from this Basin-and-Range

  7. Laboratory directed research and development annual report. Fiscal year 1994

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-01

    The Department of Energy Order DOE 5000.4A establishes DOE`s policy and guidelines regarding Laboratory Directed Research and Development (LDRD) at its multiprogram laboratories. This report represents Pacific Northwest Laboratory`s (PNL`s) LDRD report for FY 1994. During FY 1994, 161 LDRD projects were selected for support through PNL`s LDRD project selection process. Total funding allocated to these projects was $13.7 million. Consistent with the Mission Statement and Strategic Plan provided in PNL`s Institutional Plan, the LDRD investments are focused on developing new and innovative approaches in research related to our {open_quotes}core competencies.{close_quotes} Currently, PNL`s core competencies have been identified as integrated environmental research; process science and engineering; energy systems development. In this report, the individual summaries of LDRD projects (presented in Section 1.0) are organized according to these core competencies. The largest proportion of Laboratory-level LDRD funds is allocated to the core competency of integrated environmental research. Projects within the three core competency areas were approximately 91.4 % of total LDRD project funding at PNL in FY 1994. A significant proportion of PNL`s LDRD funds are also allocated to projects within the various research centers that are proposed by individual researchers or small research teams. Funding allocated to each of these projects is typically $35K or less. The projects described in this report represent PNL`s investment in its future and are vital to maintaining the ability to develop creative solutions for the scientific and technical challenges faced by DOE and the nation. The report provides an overview of PNL`s LDRD program, the management process used for the program, and project summaries for each LDRD project.

  8. Storage of LWR spent fuel in air: Volume 1: Design and operation of a spent fuel oxidation test facility

    International Nuclear Information System (INIS)

    Thornhill, C.K.; Campbell, T.K.; Thornhill, R.E.

    1988-12-01

    This report describes the design and operation and technical accomplishments of a spent-fuel oxidation test facility at the Pacific Northwest Laboratory. The objective of the experiments conducted in this facility was to develop a data base for determining spent-fuel dry storage temperature limits by characterizing the oxidation behavior of light-water reactor (LWR) spent fuels in air. These data are needed to support licensing of dry storage in air as an alternative to spent-fuel storage in water pools. They are to be used to develop and validate predictive models of spent-fuel behavior during dry air storage in an Independent Spent Fuel Storage Installation (ISFSI). The present licensed alternative to pool storage of spent fuel is dry storage in an inert gas environment, which is called inerted dry storage (IDS). Licensed air storage, however, would not require monitoring for maintenance of an inert-gas environment (which IDS requires) but does require the development of allowable temperature limits below which UO 2 oxidation in breached fuel rods would not become a problem. Scoping tests at PNL with nonirradiated UO 2 pellets and spent-fuel fragment specimens identified the need for a statistically designed test matrix with test temperatures bounding anticipated maximum acceptable air-storage temperatures. This facility was designed and operated to satisfy that need. 7 refs

  9. Introduction to the Chemical Management System

    International Nuclear Information System (INIS)

    Sawyer, J.G.

    1993-01-01

    The CMS, a Laboratory-wide electronic chemical inventory tracking system, will assist PNL by establishing comprehensive, integrated, Laboratory-wide databases supported by consistent and standardized procedures for chemical inventory management. It will provide PNL with the information needed to meet its current chemical management responsibilities and regulatory requirements. Its objectives are to provide an inventory of all chemicals being held at PNL facilities, to provide a specific location for all chemical containers, to ensure that health and safety regulatory codes are being upheld, and to provide PNL staff and managers with hazardous-chemical information for better inventory management. It is composed of 5 modules: chemical purchasing; chemical inventory; chemical names, properties, and hazardous groups; reporting; and system manager

  10. Boat sampling technique for assessment of ageing of components

    International Nuclear Information System (INIS)

    Kumar, Kundan; Shyam, T.V.; Kayal, J.N.; Rupani, B.B.

    2006-01-01

    Boat sampling technique (BST) is a surface sampling technique, which has been developed for obtaining, in-situ, metal samples from the surface of an operating component without affecting its operating service life. The BST is non-destructive in nature and the sample is obtained without plastic deformation or without thermal degradation of the parent material. The shape and size of the sample depends upon the shape of the cutter and the surface geometry of the parent material. Miniature test specimens are generated from the sample and the specimens are subjected to various tests, viz. Metallurgical Evaluation, Metallographic Evaluation, Micro-hardness Evaluation, sensitisation test, small punch test etc. to confirm the integrity and assessment of safe operating life of the component. This paper highlights design objective of boat sampling technique, description of sampling module, sampling cutter and its performance evaluation, cutting process, boat samples, operational sequence of sampling module, qualification of sampling module, qualification of sampling technique, qualification of scooped region of the parent material, sample retrieval system, inspection, testing and examination to be carried out on the boat samples and scooped region. (author)

  11. Standardizing operational vector sampling techniques for measuring malaria transmission intensity: evaluation of six mosquito collection methods in western Kenya.

    Science.gov (United States)

    Wong, Jacklyn; Bayoh, Nabie; Olang, George; Killeen, Gerry F; Hamel, Mary J; Vulule, John M; Gimnig, John E

    2013-04-30

    Operational vector sampling methods lack standardization, making quantitative comparisons of malaria transmission across different settings difficult. Human landing catch (HLC) is considered the research gold standard for measuring human-mosquito contact, but is unsuitable for large-scale sampling. This study assessed mosquito catch rates of CDC light trap (CDC-LT), Ifakara tent trap (ITT), window exit trap (WET), pot resting trap (PRT), and box resting trap (BRT) relative to HLC in western Kenya to 1) identify appropriate methods for operational sampling in this region, and 2) contribute to a larger, overarching project comparing standardized evaluations of vector trapping methods across multiple countries. Mosquitoes were collected from June to July 2009 in four districts: Rarieda, Kisumu West, Nyando, and Rachuonyo. In each district, all trapping methods were rotated 10 times through three houses in a 3 × 3 Latin Square design. Anophelines were identified by morphology and females classified as fed or non-fed. Anopheles gambiae s.l. were further identified as Anopheles gambiae s.s. or Anopheles arabiensis by PCR. Relative catch rates were estimated by negative binomial regression. When data were pooled across all four districts, catch rates (relative to HLC indoor) for An. gambiae s.l (95.6% An. arabiensis, 4.4% An. gambiae s.s) were high for HLC outdoor (RR = 1.01), CDC-LT (RR = 1.18), and ITT (RR = 1.39); moderate for WET (RR = 0.52) and PRT outdoor (RR = 0.32); and low for all remaining types of resting traps (PRT indoor, BRT indoor, and BRT outdoor; RR < 0.08 for all). For Anopheles funestus, relative catch rates were high for ITT (RR = 1.21); moderate for HLC outdoor (RR = 0.47), CDC-LT (RR = 0.69), and WET (RR = 0.49); and low for all resting traps (RR < 0.02 for all). At finer geographic scales, however, efficacy of each trap type varied from district to district. ITT, CDC-LT, and WET appear to be effective methods for large-scale vector sampling in

  12. Sampling and analysis plan for the site characterization of the waste area Grouping 1 groundwater operable unit at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    1994-11-01

    Waste Area Grouping (WAG) 1 at Oak Ridge National Laboratory (ORNL) includes all of the former ORNL radioisotope research, production, and maintenance facilities; former waste management areas; and some former administrative buildings. Site operations have contaminated groundwater, principally with radiological contamination. An extensive network of underground pipelines and utilities have contributed to the dispersal of contaminants to a known extent. In addition, karst geology, numerous spills, and pipeline leaks, together with the long and varied history of activities at specific facilities at ORNL, complicate contaminant migration-pathway analysis and source identification. To evaluate the extent of contamination, site characterization activity will include semiannual and annual groundwater sampling, as well as monthly water level measurements (both manual and continuous) at WAG 1. This sampling and analysis plan provides the methods and procedures to conduct site characterization for the Phase 1 Remedial Investigation of the WAG 1 Groundwater Operable Unit

  13. Cooperative study of clinical benefits from use of the fully portable blood irradiator

    International Nuclear Information System (INIS)

    Hungate, F.P.

    1994-10-01

    This report looks at the clinical benefits from use of a fully portable blood irradiator, techniques developed by Pacific Northwest Laboratory. Significant accomplishments included the following: blood irradiators were successfully fabricated by PNL; irradiators were activated at the University of Missouri and quality tested at PNL; A-V shunts for irradiators were successfully fabricated in the PNL plastics shop; all activities necessary for experimental work on animals using the blood irradiators were completed

  14. Analysis and Simulation of 3D Scattering due to Heterogeneous Crustal Structure and Surface Topography on Regional Phases; Magnitude and Discrimination

    Science.gov (United States)

    2009-07-07

    inversion technique that is based on different weights for relatively high frequency waveform modeling of Pnl and relatively long period surface waves (Tan...et al., 2006). Pnl and surface waves are also allowed to shift in time to take into account of uncertainties in velocity structure. Joint...inversion of Pnl and surface waves provides better constraints on focal depth as well as source mechanisms. The pure strike-slip mechanism of the earthquake

  15. Hydromagnetic Waves and Instabilities in Kappa Distribution Plasma

    Science.gov (United States)

    2009-01-01

    perpendicular effective particle temperatures, respec- tively. Two other parameters related to pM and pnl which naturally occur in the study of...role in determin- ing the excitation conditions of the field swelling and mirror instabilities [see Eqs. (60) and (65)]. Calculating pnl /pni from Eq...more convenient form of the perturbed distribution function /„ that may be used in- stead of Eq. (12) to obtain nn, pM, and pnl given by Eqs. (72

  16. High Velocity Jet Noise Source Location and Reduction. Task 3 - Experimental Investigation of Suppression Principles. Volume I. Suppressor Concepts Optimization

    Science.gov (United States)

    1978-12-01

    25. Predicted Vs. Measured PNL Directivity for an 8-Lobe Daisy Suppressor ( Aerotrain ); Va = 0. 168 4-26. Predicted Vs. Measured PNL Directivity for...of Configurations for Verification of Suppression Principles. 137 4-2. PNL Data/Theory Comparison for Bertin Aerotrain Test Series; 400-ft Sideline...obtained from the scale-model tests con- ducted in Task 3 and from the Aerotrain tests conducted in Task 4 of the present program. Comparisons were

  17. Cooperative study of clinical benefits from use of the fully portable blood irradiator

    Energy Technology Data Exchange (ETDEWEB)

    Hungate, F.P.

    1994-10-01

    This report looks at the clinical benefits from use of a fully portable blood irradiator, techniques developed by Pacific Northwest Laboratory. Significant accomplishments included the following: blood irradiators were successfully fabricated by PNL; irradiators were activated at the University of Missouri and quality tested at PNL; A-V shunts for irradiators were successfully fabricated in the PNL plastics shop; all activities necessary for experimental work on animals using the blood irradiators were completed.

  18. Factors affecting stone-free rate and complications of percutaneous nephrolithotomy for treatment of staghorn stone.

    Science.gov (United States)

    el-Nahas, Ahmed R; Eraky, Ibrahim; Shokeir, Ahmed A; Shoma, Ahmed M; el-Assmy, Ahmed M; el-Tabey, Nasr A; Soliman, Shady; Elshal, Ahmed M; el-Kappany, Hamdy A; el-Kenawy, Mahmoud R

    2012-06-01

    To determine factors affecting the stone-free rate and complications of percutaneous nephrolithotomy (PNL) for treatment of staghorn stones. The computerized database of patients who underwent PNL for treatment of staghorn stones between January 2003 and January 2011 was reviewed. All perioperative complications were recorded and classified according to modified Clavien classification system. The stone-free rate was evaluated with low-dose noncontrast computed tomography (CT). Univariate and multivariate statistical analyses were performed to determine factors affecting stone-free and complication rates. The study included 241 patients (125 male and 116 female) with a mean age of 48.7 ±14.3 years. All patients underwent 251 PNL (10 patients had bilateral stones). The stone-free rate of PNL monotherapy was 56% (142 procedures). At 3 months, the stone-free rate increased to 73% (183 kidneys) after shock wave lithotripsy. Independent risk factors for residual stones were complete staghorn stone and presence of secondary calyceal stones (relative risks were 2.2 and 3.1, respectively). The complication rate was 27% (68 PNL). Independent risk factors for development of complications were performance of the procedure by urologists other than experienced endourologist and positive preoperative urine culture (relative risks were 2.2 and 2.1, respectively). Factors affecting the incidence of residual stones after PNL are complete staghorn stones and the presence of secondary calyceal stones. Complications are significantly high if PNL is not performed by an experienced endourologist or if preoperative urine culture is positive. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Percutaneous nephrolithotomy versus extracorporeal shock wave lithotripsy for moderate sized kidney stones.

    Science.gov (United States)

    Deem, Samuel; Defade, Brian; Modak, Asmita; Emmett, Mary; Martinez, Fred; Davalos, Julio

    2011-10-01

    To compare the outcomes of percutaneous nephrolithotomy (PNL) and extracorporeal shock wave lithotripsy (ESWL) for moderate sized (1-2 cm) upper and middle pole renal calculi in regards to stone clearance rate, morbidity, and quality of life. All patients diagnosed with moderate sized upper and middle pole kidney stones by computed tomography (CT) were offered enrollment. They were randomized to receive either ESWL or PNL. The SF-8 quality of life survey was administered preoperatively and at 1 week and 3 months postoperatively. Abdominal radiograph at 1 week and CT scan at 3 months were used to determine stone-free status. All complications and outcomes were recorded. PNL established a stone-free status of 95% and 85% at 1 week and 3 months, respectively, whereas ESWL established a stone-free status of 17% and 33% at 1 week and 3 months, respectively. Retreatment in ESWL was required in 67% of cases, with 0% retreatment in PNL. Stone location, stone density, and skin-to-stone distance had no impact on stone-free rates at both visits, irrespective of procedure. Patient-reported outcomes, including overall physical and mental health status, favored a better quality of life for patients who had PNL performed. PNL more often establishes stone-free status, has a more similar complication profile, and has similar reported quality of life at 3 months when compared with ESWL for moderate-sized kidney stones. PNL should be offered as a treatment option to all patients with moderate-sized kidney stones in centers with experienced endourologists. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Management of calyceal diverticular calculi: a comparison of percutaneous nephrolithotomy and flexible ureterorenoscopy.

    Science.gov (United States)

    Bas, Okan; Ozyuvali, Ekrem; Aydogmus, Yasin; Sener, Nevzat Can; Dede, Onur; Ozgun, Serhat; Hizli, Fatih; Senocak, Cagri; Bozkurt, Omer Faruk; Basar, Halil; Imamoglu, Abdurrahim

    2015-04-01

    To compare the outcomes in patients who have been treated with flexible ureterorenoscopy (f-URS) and percutaneous nephrolithotomy (PNL) in managing stone-bearing caliceal diverticula. Between April 2007 and October 2013, we performed a retrospective analysis of 54 evaluable patients (28 women and 26 men) with symptomatic stone-bearing caliceal diverticula, who underwent PNL (n = 29) or F-URS (n = 25) in four referral hospitals in Turkey. The groups were compared with respect to demographics, stone location/size, success rate, stone-free status, symptom-free status, complication rates, and hospital stay. The average stone burden preoperatively was significantly larger in patients who were treated with PNL, with the average size for f-URS being 154 ± 77 mm(2) and that for PNL being 211 ± 97 mm(2) (p = 0.023). Symptom-free rates, success rates, stone-free rates and clinically insignificant residual fragments were similar between the groups (p = 0.880 vs. p = 0.537 vs. p = 0.539, and p = 0.877, respectively). There was no statistical difference between the groups for minor complications (p = 0.521) but no major complication (Clavien III-V) occured in the f-URS group; although there were three major complications (10.3 %) (Clavien III) in the PNL group (p PNL group (p PNL. The f-URS procedure is advantageous with respect to a shorter hospital stay and absence of major complications. Therefore, it should be emphasized that the location of the stone and diverticula is an important factor for the selection of the procedure.

  1. Tubeless percutaneous nephrolithotomy with non-absorbable hemostatic sealant (Quikclot®) versus nephrostomy tube placement: a propensity score-matched analysis.

    Science.gov (United States)

    Koo, Kyo Chul; Park, Sang Un; Jang, Ho Sung; Hong, Chang-Hee

    2015-11-01

    The purpose of this study was to determine the efficacy and safety of tubeless percutaneous nephrolithotomy (PNL) using a non-absorbable hemostatic sealant (Quikclot(®)) as an adjunct compared to nephrostomy tube placement in patients exhibiting significant parenchymal bleeding following PNL. We identified 113 PNL cases performed between May 2011 and October 2014. For patients with insignificant parenchymal bleeding following stone removal, defined as a clear visualization of the surgical field at full irrigation of the nephroscope, tubeless PNL was performed. For patients with significant parenchymal bleeding, we introduced the tubeless Quikclot(®) technique as of September 2013 and have performed it ever since. Formerly, nephrostomy placement PNL was performed. In this study, 40 Quikclot(®) applied PNL cases were matched with an equal number of nephrostomy placement cases by propensity scoring based on body mass index, stone size, and Guy's stone score. The mean postoperative drop in hematocrit was comparative between the Quikclot(®) group and the nephrostomy group on both postoperative days 1 (p = 0.459) and 2 (p = 0.325). Quikclot(®) application was associated with lower VAS scores throughout the postoperative period, lower cumulative analgesic requirement (p = 0.025), and with shorter hospitalization (p = 0.002). Complication rates were comparable with no need for blood transfusions in any patients. Tubeless Quikclot(®) PNL was safe and provided effective hemostasis of significant parenchymal bleeding. By avoiding nephrostomy placement, we were able to reduce postoperative pain, analgesic requirements, and hospitalization. Application of Quikclot(®) may be considered prior to nephrostomy placement in patients with significant parenchymal bleeding.

  2. A survey for elevated levels of uranium north of the 300 Area on the Hanford Site

    International Nuclear Information System (INIS)

    Poston, T.M.

    1990-04-01

    A comprehensive survey of soil uranium (U) concentrations in a study area due north of the 300 Area on the Hanford site has been conducted by Pacific Northwest Laboratory (PNL). The objective of the study was to determine the spatial distribution of uranium in the study area and to ascertain if background levels of uranium have been increased by Hanford operations. Based on the spatial distribution of 238 U, the highest concentrations of uranium are located in the southern portion of the study area adjacent to the 300 Area complex and in the most eastern zone of the study site bordering the Columbia River. Uranium-236, an isotopic marker of fuel processing activities in the 300 Area, was detected in all eight samples selected from the study. A significant and positive regression was demonstrated between the ratios of 236 U/ 238 U in these eight samples and proximity to the 300 Area. 9 refs., 18 figs., 9 tabs

  3. An update on percutaneous nephrolithotomy

    DEFF Research Database (Denmark)

    Tefekli, A; Cordeiro, E; de la Rosette, J J M C H

    2013-01-01

    Since its introduction in late 1970's, percutaneous nephrolithotomy (PNL) has undergone an evolution in both equipment and technique. This evolution still continues today in the era of minimally invasive treatment options, and is evidenced by the numerous publications. PNL is generally advantageous...... in the management of large renal stones (>1.5-2 cm) with high stone-free rates and considerable complication rates. However this technique is especially competing with retrograde intrarenal surgery and laparoscopic techniques. Therefore the CROES Global PNL Study Group prospectively collected data of over 5800...... patients managed with PNL worldwide and analyzed the data in detail, producing more than 25 scientific papers. And this update focuses on the lessons learned from the CROES PCNL Global Study....

  4. Adhoc Wireless Network Control: Energy Efficiency and Hidden Terminal Considerations

    Science.gov (United States)

    2009-12-01

    Pnl (t) +Bn(t), Emax ) , (57) Ynl(t+ 1) = [Ynl(t)−Rnl,in(t)] + + γnl(t), (58) Dn(t+ 1) = [Dn(t...1− δ)Bn(t)] + + ∑ l∈On Pnl (t), (59) subject to constraints Rnl,in(t) ≤ Vnl(t) +Anl(t) ∀n, l, t, P (t) ∈ PS(t), ∑ l∈On Pnl (t) ≤ min ( En(t), P̂ ) ∀n...γnl(t)] ∣ ∣ ∣ ∣ ∣ ∣ X(t)   − 2E   ∑ n,l [Unl(t)µnl (S(t),P (t))−Dn(t) Pnl (t)] ∣ ∣ ∣ ∣ ∣ ∣ X(t)  − 2E   ∑ n,l [ηYnl(t)−

  5. Quality programs for waste management research and development

    International Nuclear Information System (INIS)

    Hood, F.C.

    1990-06-01

    The Pacific Northwest Laboratory (PNL) is a US Department of Energy (DOE) multi-program national laboratory. PNL develops waste management processes and techniques as well as providing management services for characterization and remediation of radioactive and/or hazardous waste sites for the DOE. This paper deals with the application of total quality management principles to waste management research and development activities at PNL. The PNL Quality Program has evolved with expanding expectations for ''error-free'' performance from the client and the public sector; it describes the management controls needed to achieve desired levels of product quality and to verify they are reached. It includes the definition of work requirements, performance objectives, roles and responsibilities, performance indicators and measurement, performance feedback mechanisms, and process improvement methodologies. 6 refs

  6. Tract Sizes in Miniaturized Percutaneous Nephrolithotomy: A Systematic Review from the European Association of Urology Urolithiasis Guidelines Panel.

    Science.gov (United States)

    Ruhayel, Yasir; Tepeler, Abdulkadir; Dabestani, Saeed; MacLennan, Steven; Petřík, Aleš; Sarica, Kemal; Seitz, Christian; Skolarikos, Andreas; Straub, Michael; Türk, Christian; Yuan, Yuhong; Knoll, Thomas

    2017-08-01

    Miniaturized instruments for percutaneous nephrolithotomy (PNL), utilizing tracts sized ≤22 Fr, have been developed in an effort to reduce the morbidity and increase the efficiency of stone removal compared with standard PNL (>22 Fr). We systematically reviewed all available evidence on the efficacy and safety of miniaturized PNL for removing renal calculi. The review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses statement. Since it was not possible to perform a meta-analysis, the data were summarized in a narrative synthesis. After screening 2945 abstracts, 18 studies were included (two randomized controlled trials [RCTs], six nonrandomized comparative studies, and 10 case series). Thirteen studies were full-text articles and five were only available as congress abstracts. The size of tracts used in miniaturized procedures ranged from 22 Fr to 4.8 Fr. The largest mean stone size treated using small instruments was 980mm 2 . Stone-free rates were comparable in miniaturized and standard PNL procedures. Procedures performed with small instruments tended to be associated with significantly lower blood loss, while the procedure duration tended to be significantly longer. Other complications were not notably different between PNL types. Study designs and populations were heterogeneous. Study limitations included selection and outcome reporting bias, as well as a lack of information on relevant confounding factors. The studies suggest that miniaturized PNL is at least as efficacious and safe as standard PNL for the removal of renal calculi. However, the quality of the evidence was poor, drawn mainly from small studies, the majority of which were single-arm case series, and only two of which were RCTs. Furthermore, the tract sizes used and types of stones treated were heterogeneous. Hence, the risks of bias and confounding were high, highlighting the need for more reliable data from RCTs. Removing kidney stones via

  7. Binding of peanut lectin to germinal-centre cells: a marker for B-cell subsets of follicular lymphoma?

    OpenAIRE

    Rose, M. L.; Habeshaw, J. A.; Kennedy, R.; Sloane, J.; Wiltshaw, E.; Davies, A. J.

    1981-01-01

    The binding of horseradish-peroxidase-labelled peanut lectin (HRP-PNL) to cryostat sections of tonsil, lymphoma lymph nodes, reactive lymph nodes and miscellaneous tumours demonstrated that PNL binds selectively to lymphocytes in germinal centres. Lymph nodes from 21 patients with non-Hodgkin's lymphomas were phenotyped as cell suspensions for PNL binding, and the following surface markers: E rosetting, C3d, SIg, OK markers of T-cell subsets, Ig heavy-chain and light-chain classes. There was ...

  8. Model of rotary-actuated flexible beam with notch filter vibration suppression controller and torque feedforward load compensation controller

    International Nuclear Information System (INIS)

    Bills, K.C.; Kress, R.L.; Kwon, D.S.; Baker, C.P.

    1994-01-01

    This paper describes ORNL's development of an environment for the simulation of robotic manipulators. Simulation includes the modeling of kinematics, dynamics, sensors, actuators, control systems, operators, and environments. Models will be used for manipulator design, proposal evaluation, control system design and analysis, graphical preview of proposed motions, safety system development, and training. Of particular interest is the development of models for robotic manipulators having at least one flexible link. As a first application, models have been developed for the Pacific Northwest Laboratory's Flexible Beam Test Bed (PNL FBTB), which is a 1-Degree-of-Freedom, flexible arm with a hydraulic base actuator. ORNL transferred control algorithms developed for the PNL FBTB to controlling IGRIP models. A robust notch filter is running in IGRIP controlling a full dynamics model of the PNL test bed. Model results provide a reasonable match to the experimental results (quantitative results are being determined) and can run on ORNL's Onyx machine in approximately realtime. The flexible beam is modeled as six rigid sections with torsional springs between each segment. The spring constants were adjusted to match the physical response of the flexible beam model to the experimental results. The controller is able to improve performance on the model similar to the improvement seen on the experimental system. Some differences are apparent, most notably because the IGRIP model presently uses a different trajectory planner than the one used by ORNL on the PNL test bed. In the future, the trajectory planner will be modified so that the experiments and models are the same. The successful completion of this work provides the ability to link C code with IGRIP, thus allowing controllers to be developed, tested, and tuned in simulation and then ported directly to hardware systems using the C language

  9. Pacific Northwest Laboratory annual report for 1994 to the DOE Office of Energy Research. Part 2: Atmospheric and climate research

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-01

    Atmospheric research at Pacific Northwest Laboratory (PNL) occurs in conjunction with the Atmospheric Chemistry Program (ACP) and with the Atmospheric Studies in Complex Terrain (ASCOT) Program. Solicitations for proposals and peer review were used to select research projects for funding in FY 1995. Nearly all ongoing projects were brought to a close in FY 1994. Therefore, the articles in this volume include a summary of the long-term accomplishments as well as the FY 1994 progress made on these projects. The following articles present summaries of the progress in FY 1994 under these research tasks: continental and oceanic fate of pollutants; research aircraft operations; ASCOT program management; coupling/decoupling of synoptic and valley circulations; interactions between surface exchange processes and atmospheric circulations; and direct simulations of atmospheric turbulence. Climate change research at PNL is aimed at reducing uncertainties in the fundamental processes that control climate systems that currently prevent accurate predictions of climate change and its effects. PNL is responsible for coordinating and integrating the field and laboratory measurement programs, modeling studies, and data analysis activities of the Atmospheric Radiation Measurements (ARM) program. In FY 1994, PNL scientists conducted 3 research projects under the ARM program. In the first project, the sensitivity of GCM grid-ad meteorological properties to subgrid-scale variations in surface fluxes and subgrid-scale circulation patterns is being tested in a single column model. In the second project, a new and computationally efficient scheme has been developed for parameterizing stratus cloud microphysics in general circulation models. In the last project, a balloon-borne instrument package is being developed for making research-quality measurements of radiative flux divergence profiles in the lowest 1,500 meters of the Earth`s atmosphere.

  10. Concrete material characterization reinforced concrete tank structure Multi-Function Waste Tank Facility

    International Nuclear Information System (INIS)

    Winkel, B.V.

    1995-01-01

    The purpose of this report is to document the Multi-Function Waste Tank Facility (MWTF) Project position on the concrete mechanical properties needed to perform design/analysis calculations for the MWTF secondary concrete structure. This report provides a position on MWTF concrete properties for the Title 1 and Title 2 calculations. The scope of the report is limited to mechanical properties and does not include the thermophysical properties of concrete needed to perform heat transfer calculations. In the 1970's, a comprehensive series of tests were performed at Construction Technology Laboratories (CTL) on two different Hanford concrete mix designs. Statistical correlations of the CTL data were later generated by Pacific Northwest Laboratories (PNL). These test results and property correlations have been utilized in various design/analysis efforts of Hanford waste tanks. However, due to changes in the concrete design mix and the lower range of MWTF operating temperatures, plus uncertainties in the CTL data and PNL correlations, it was prudent to evaluate the CTL data base and PNL correlations, relative to the MWTF application, and develop a defendable position. The CTL test program for Hanford concrete involved two different mix designs: a 3 kip/in 2 mix and a 4.5 kip/in 2 mix. The proposed 28-day design strength for the MWTF tanks is 5 kip/in 2 . In addition to this design strength difference, there are also differences between the CTL and MWTF mix design details. Also of interest, are the appropriate application of the MWTF concrete properties in performing calculations demonstrating ACI Code compliance. Mix design details and ACI Code issues are addressed in Sections 3.0 and 5.0, respectively. The CTL test program and PNL data correlations focused on a temperature range of 250 to 450 F. The temperature range of interest for the MWTF tank concrete application is 70 to 200 F

  11. Hanford Sampling Quality Management Plan (HSQMP)

    International Nuclear Information System (INIS)

    Hyatt, J.E.

    1995-06-01

    HSQMP establishes quality requirements in response to DOE Order 5700. 6C and to 10 Code of Federal Regulations 830.120. HSQMP is designed to meet the needs of Richland Operations Office for controlling the quality of services provided by sampling operations. It is issued through the Analytical Services Program of the Waste Programs Division. This document describes the Environmental Sampling and Analysis Program activities considered to represent the best management activities necessary to achieve a sampling program with adequate control

  12. Digital Microfluidics Sample Analyzer

    Science.gov (United States)

    Pollack, Michael G.; Srinivasan, Vijay; Eckhardt, Allen; Paik, Philip Y.; Sudarsan, Arjun; Shenderov, Alex; Hua, Zhishan; Pamula, Vamsee K.

    2010-01-01

    Three innovations address the needs of the medical world with regard to microfluidic manipulation and testing of physiological samples in ways that can benefit point-of-care needs for patients such as premature infants, for which drawing of blood for continuous tests can be life-threatening in their own right, and for expedited results. A chip with sample injection elements, reservoirs (and waste), droplet formation structures, fluidic pathways, mixing areas, and optical detection sites, was fabricated to test the various components of the microfluidic platform, both individually and in integrated fashion. The droplet control system permits a user to control droplet microactuator system functions, such as droplet operations and detector operations. Also, the programming system allows a user to develop software routines for controlling droplet microactuator system functions, such as droplet operations and detector operations. A chip is incorporated into the system with a controller, a detector, input and output devices, and software. A novel filler fluid formulation is used for the transport of droplets with high protein concentrations. Novel assemblies for detection of photons from an on-chip droplet are present, as well as novel systems for conducting various assays, such as immunoassays and PCR (polymerase chain reaction). The lab-on-a-chip (a.k.a., lab-on-a-printed-circuit board) processes physiological samples and comprises a system for automated, multi-analyte measurements using sub-microliter samples of human serum. The invention also relates to a diagnostic chip and system including the chip that performs many of the routine operations of a central labbased chemistry analyzer, integrating, for example, colorimetric assays (e.g., for proteins), chemiluminescence/fluorescence assays (e.g., for enzymes, electrolytes, and gases), and/or conductometric assays (e.g., for hematocrit on plasma and whole blood) on a single chip platform.

  13. Requested information regarding remote analytical capabilities

    International Nuclear Information System (INIS)

    Steel, R.T.

    1991-09-01

    This document describes a new method for analysis of cyanide in radioactive waste samples from the Hanford Site. The new assay is designed to increase throughput of samples, reduce waste volumes and decrease radiation exposure to analysts. The system is based on the Lachat Micro-Dist TM microdistillation system. This document contains the reference and methods manual for this kit, and also the specific PNL lab procedures for using this kit. 6 refs., 20 figs

  14. Unit environmental transport assessment of contaminants from Hanford's past-practice waste sites. Hanford Remedial Action Environmental Impact Statement

    International Nuclear Information System (INIS)

    Whelan, G.; Buck, J.W.; Castleton, K.J.

    1995-06-01

    The US Department of Energy, Richland Operations Office (DOE-RL) contracted Pacific Northwest Laboratory (PNL) to provide support to Advanced Sciences, Incorporated (ASI) in implementing tile regional no-action risk assessment in the Hanford Remedial Action Environmental Impact Statement. Researchers at PNL were charged with developing unit concentrations for soil, groundwater, surface water, and air at multiple locations within an 80-km radius from the center of tile Hanford installation. Using the Multimedia Environmental Pollutant Assessment System (MEPAS), PNL simulated (1) a unit release of one ci for each radionuclide and one kg for each chemical from contaminated soils and ponded sites, (2) transport of the contaminants in and through various environmental media and (3) exposure/risk of four exposure scenarios, outlined by the Hanford Site Baseline Remedial Action Methodology. These four scenarios include residential, recreational, industrial, and agricultural exposures. Spacially and temporally distributed environmental concentrations based on unit releases of radionuclides and chemicals were supported to ASI in support of the HRA-EIS. Risk for the four exposure scenarios, based on unit environment concentrations in air, water, and soil. were also supplied to ASI. This report outlines the procedure that was used to implement the unit transport portion of the HRA-EIS baseline risk assessment. Deliverables include unit groundwater, surface water, air, and soil concentrations at multiple locations within an 80-km radius from the center of the Hanford installation

  15. Patrick Air Force Base integrated resource assessment. Volume 3, Resource assessment

    Energy Technology Data Exchange (ETDEWEB)

    Sandusky, W.F.; Parker, S.A.; King, D.A.; Wahlstrom, R.R.; Elliott, D.B.; Shankle, S.A.

    1993-12-01

    The US Air Force has tasked the Pacific Northwest Laboratory (PNL) in support of the US Department of Energy Federal Energy Management Program to identify, evaluate, and assist in acquiring all cost effective energy projects at Patrick Air Force Base (AFB). This is part of a model program that PNL is designing to support energy-use decisions in the federal sector. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at Patrick AFB which is located south of Cocoa Beach, Florida. It is a companion report to Volume 1, Executive Summary, and Volume.2, Baseline Detail. The results of the analyses of EROs are presented in 11 common energy end-use categories. A narrative description of each ERO is provided, including information on the installed cost, energy and dollar savings, impacts on operations and maintenance, and, when applicable, a discussion of energy supply and demand, energy security, and environmental issues. A description of the evaluation methodologies and technical and cost assumptions is also provided for each ERO. Summary tables present the cost-effectiveness of energy end-use equipment before and after the implementation of each ERO and present the results of the life-cycle cost analysis indicating the net present value and value index of each ERO.

  16. A safety equipment list for rotary mode core sampling systems operation in single shell flammable gas tanks; TOPICAL

    International Nuclear Information System (INIS)

    SMALLEY, J.L.

    1999-01-01

    This document identifies all interim safety equipment to be used for rotary mode core sampling of single-shell flammable gas tanks utilizing Rotary Mode Core Sampling systems (RMCS). This document provides the safety equipment for RMCS trucks HO-68K-4600, HO-68K-4647, trucks three and four respectively, and associated equipment. It is not intended to replace or supersede WHC-SD-WM-SEL-023, (Kelly 1991), or WHC-SD-WM-SEL-032, (Corbett 1994), which classifies 80-68K-4344 and HO-68K-4345 respectively. The term ''safety equipment'' refers to safety class (SC) and safety significant (SS) equipment, where equipment refers to structures, systems and components (SSC's). The identification of safety equipment in this document is based on the credited design safety features and analysis contained in the Authorization Basis (AB) for rotary mode core sampling operations in single-shell flammable gas tanks. This is an interim safety classification since the AB is interim. This document will be updated to reflect the final RMCS equipment safety classification designations upon completion of a final AB which will be implemented with the release of the Final Safety Analysis Report (FSAR)

  17. Meet the best Award-winning technologies from Pacific Northwest Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    1990-09-01

    The Battelle Memorial Institute has managed the Pacific Northwest Laboratory (PNL) for the US Department of Energy for 25 years. During this time, numerous new technologies have been discovered and developed at PNL as a result of our research programs. This document will introduce you to some of the more significant discoveries and newly commercialized technologies. Each of the technologies described has received an award from Research Development magazine or the Federal Laboratory Consortium--sometimes both Each technology is available to you through PNL's technology transfer program or one of our licensees. Similarly, our award-winning scientists and engineers are available to assist you as you search for innovative technologies to solve your technical problems. These researchers are familiar with current problems confronting industry, government agencies, and the academic community. They are happy to apply their skills and PNL's resources to your problems. PNL encourages its researchers to work with government agencies, universities, and US industries. PNL technology transfer programs address the nation's drive toward increased competitiveness by being flexible and aggressive, and are designed to tailor results to fit your needs and those of your clients. If you are in search of a new technology or increased competitiveness, consider collaborative efforts with our award-winning staff, whose accomplishments are synopsized in this booklet.

  18. Measurement of peak impact loads differ between accelerometers - Effects of system operating range and sampling rate.

    Science.gov (United States)

    Ziebart, Christina; Giangregorio, Lora M; Gibbs, Jenna C; Levine, Iris C; Tung, James; Laing, Andrew C

    2017-06-14

    A wide variety of accelerometer systems, with differing sensor characteristics, are used to detect impact loading during physical activities. The study examined the effects of system characteristics on measured peak impact loading during a variety of activities by comparing outputs from three separate accelerometer systems, and by assessing the influence of simulated reductions in operating range and sampling rate. Twelve healthy young adults performed seven tasks (vertical jump, box drop, heel drop, and bilateral single leg and lateral jumps) while simultaneously wearing three tri-axial accelerometers including a criterion standard laboratory-grade unit (Endevco 7267A) and two systems primarily used for activity-monitoring (ActiGraph GT3X+, GCDC X6-2mini). Peak acceleration (gmax) was compared across accelerometers, and errors resulting from down-sampling (from 640 to 100Hz) and range-limiting (to ±6g) the criterion standard output were characterized. The Actigraph activity-monitoring accelerometer underestimated gmax by an average of 30.2%; underestimation by the X6-2mini was not significant. Underestimation error was greater for tasks with greater impact magnitudes. gmax was underestimated when the criterion standard signal was down-sampled (by an average of 11%), range limited (by 11%), and by combined down-sampling and range-limiting (by 18%). These effects explained 89% of the variance in gmax error for the Actigraph system. This study illustrates that both the type and intensity of activity should be considered when selecting an accelerometer for characterizing impact events. In addition, caution may be warranted when comparing impact magnitudes from studies that use different accelerometers, and when comparing accelerometer outputs to osteogenic impact thresholds proposed in literature. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  19. Chemical laboratory hazardous waste management at a DOE multiprogram national laboratory

    International Nuclear Information System (INIS)

    Turner, P.J.

    1990-03-01

    Pacific Northwest Laboratory (PNL), a United States Department of Energy (DOE) Multiprogram Energy Laboratory, is establishing a program for management of diverse small-quantity laboratory waste generated on site. Although the main emphasis of this program is ''cradle-to-grave'' tracking and treatment of hazardous chemical waste and mixed waste, low-level radioactive and transuranic (TRU) waste is also being included. With the program in operation, more than 95% of all regulated waste will be treated or destroyed on site. The cost savings will return the original investment in under six years and decrease the liability to PNL and DOE -- a benefit with a potentially greater economic value. Tracking of hazardous waste will be mediated by a computer-based inventory and tracking system. The system will track all hazardous materials from receipt through final disposition, whether the material is destroyed or treated for disposal. It will allow user access to handling and hazards information as well as provide an updated inventory by location, user, and hazard type. Storage and treatment of waste will be performed by at least four facilities, made operational in three phases. 6 figs

  20. The utility of noncontrast computed tomography in the prompt diagnosis of postoperative complications after percutaneous nephrolithotomy.

    Science.gov (United States)

    Gnessin, Ehud; Mandeville, Jessica A; Handa, Shelly E; Lingeman, James E

    2012-04-01

    Noncontrast computed tomography (CT) is commonly utilized after percutaneous nephrolithotomy (PNL) to assess stone-free (SF) status. In addition to assessing SF status, CT is useful in the recognition of complications after PNL. We characterized complications demonstrated by postoperative CT scan and compared hospital re-admission rates based on whether or not CT was performed. We retrospectively reviewed records of 1032 consecutive patients from April 1999 to June 2010. Patients were divided into two cohorts based on whether they had a CT within 24 hours of PNL. Demographic data, CT findings, and need for re-admission for complication management were assessed. Nine hundred fifty-seven patients (92.7%) underwent post-PNL CT. CT-diagnosed complications were perinephric hematoma in 41 (4.3%; 2 requiring embolization and 9 necessitating transfusion), pleural effusion in 25 (2.6%; 10 requiring intervention), colon perforation in 2 (0.2%), and splenic injury in 2 (0.2%). Of patients with postoperative complications, 33% required intervention. Among patients with a CT, 6 (0.6%) were readmitted despite negative postoperative CT (four perinephric hematomas, one calyceal-pleural fistula, and one pseudoaneurysm). The sensitivity of CT for diagnosing complications was 92.7%. Seventy-five patients (7.3%) did not undergo CT post-PNL. Of these, four (5.33%) were readmitted: three for perinephric hematomas and one for ureteral clot obstruction. Patients undergoing post-PNL CT were less likely to be readmitted because of missed complications (p=0.02). Serious post-PNL complications are uncommon, but their prompt diagnosis and treatment is imperative. In addition to identifying residual stones, CT is useful in diagnosing postoperative complications. Postoperative CT could potentially be considered for all patients undergoing PNL, particularly in complex cases such as patients with anatomical abnormalities (renal anatomic abnormality or retrorenal colon), patients requiring upper

  1. The new LLNL AMS sample changer

    International Nuclear Information System (INIS)

    Roberts, M.L.; Norman, P.J.; Garibaldi, J.L.; Hornady, R.S.

    1993-01-01

    The Center for Accelerator Mass Spectrometry at LLNL has installed a new 64 position AMS sample changer on our spectrometer. This new sample changer has the capability of being controlled manually by an operator or automatically by the AMS data acquisition computer. Automatic control of the sample changer by the data acquisition system is a necessary step towards unattended AMS operation in our laboratory. The sample changer uses a fiber optic shaft encoder for rough rotational indexing of the sample wheel and a series of sequenced pneumatic cylinders for final mechanical indexing of the wheel and insertion and retraction of samples. Transit time from sample to sample varies from 4 s to 19 s, depending on distance moved. Final sample location can be set to within 50 microns on the x and y axis and within 100 microns in the z axis. Changing sample wheels on the new sample changer is also easier and faster than was possible on our previous sample changer and does not require the use of any tools

  2. Characterization of residual radionuclide contamination within and around commercial nuclear power plants

    International Nuclear Information System (INIS)

    Robertson, D.E.; Abel, K.H.; Thomas, C.W.; Lepel, E.A.; Evans, J.C.; Thomas, W.V.; Carrick, L.C.; Leale, M.W.

    1985-07-01

    To provide a statistically valid data base for the residual radionuclide inventories in nuclear power stations, Pacific Northwest Laboratory (PNL) was contracted to conduct an extensive sampling and measurements program at a number of nuclear power plants. This paper summarizes the results of the radionuclide characterization studies conducted at seven nuclear power stations from a decommissioning assessment viewpoint

  3. Remote sampling system in reprocessing: present and future perspective

    International Nuclear Information System (INIS)

    Garcha, J.S.; Balakrishnan, V.P.; Rao, M.K.

    1990-01-01

    For the process and inventory control of the reprocessing plant operation it is essential to analyse the samples from the various process vessels to assess the plant performance and take corrective action if needed in the operating parameters. In view of the very high radioactive inventory in the plant, these plants are operated remotely behind thick shielding. The liquid sampling also has to be carried out by remote techniques only as no direct approach is feasible. A vacuum assisted air lift method is employed for the purpose of obtaining samples from remotely located process vessels. A brief description of the present technique, the design criteria, various interlocks and manual operations involved during sampling and despatching the same to the analytical laboratory is given in the paper. A design approach for making the sampling system, a fully automated remote operation has been attempted in this paper. Utilisation of custom built robots and dedicated computer for the various operations and interlocks has been visualised to ensure a complete remotised system for the adoption in future plants. (author). 2 figs., 2 tabs

  4. Evaluation of personal air sampling pumps

    International Nuclear Information System (INIS)

    Ritter, P.D.; Novick, V.J.; Alvarez, J.L.; Huntsman, B.L.

    1987-01-01

    Personal air samplers are used to more conveniently obtain breathing zone samples from individuals over periods of several hours. Personal air sampling pumps must meet minimum performance levels under all working conditions to be suitable for use in radiation protection programs. In addition, the pumps should be simple to operate and as comfortable to wear as possible. Ten models of personal air sampling pumps were tested to evaluate their mechanical performance and physical characteristics. The pumps varied over a wide range in basic performance and operating features. Some of the pumps were found to have adequate performance for use in health physics air sampling applications. 3 references, 2 figures, 5 tables

  5. Waste tank characterization sampling limits

    International Nuclear Information System (INIS)

    Tusler, L.A.

    1994-01-01

    This document is a result of the Plant Implementation Team Investigation into delayed reporting of the exotherm in Tank 241-T-111 waste samples. The corrective actions identified are to have immediate notification of appropriate Tank Farm Operations Shift Management if analyses with potential safety impact exceed established levels. A procedure, WHC-IP-0842 Section 12.18, ''TWRS Approved Sampling and Data Analysis by Designated Laboratories'' (WHC 1994), has been established to require all tank waste sampling (including core, auger and supernate) and tank vapor samples be performed using this document. This document establishes levels for specified analysis that require notification of the appropriate shift manager. The following categories provide numerical values for analysis that may indicate that a tank is either outside the operating specification or should be evaluated for inclusion on a Watch List. The information given is intended to translate an operating limit such as heat load, expressed in Btu/hour, to an analysis related limit, in this case cesium-137 and strontium-90 concentrations. By using the values provided as safety flags, the analytical laboratory personnel can notify a shift manager that a tank is in potential violation of an operating limit or that a tank should be considered for inclusion on a Watch List. The shift manager can then take appropriate interim measures until a final determination is made by engineering personnel

  6. Modified Hazard Ranking System/Hazard Ranking System for sites with mixed radioactive and hazardous wastes: Software documentation

    Energy Technology Data Exchange (ETDEWEB)

    Stenner, R.D.; Peloquin, R.A.; Hawley, K.A.

    1986-11-01

    The mHRS/HRS software package was developed by the Pacific Northwest Laboratory (PNL) under contract with the Department of Energy (DOE) to provide a uniform method for DOE facilities to use in performing their Conservation Environmental Response Compensation and Liability Act (CERCLA) Phase I Modified Hazard Ranking System or Hazard Ranking System evaluations. The program is designed to remove the tedium and potential for error associated with the performing of hand calculations and the interpreting of information on tables and in reference books when performing an evaluation. The software package is designed to operate on a microcomputer (IBM PC, PC/XT, or PC/AT, or a compatible system) using either a dual floppy disk drive or a hard disk storage system. It is written in the dBASE III language and operates using the dBASE III system. Although the mHRS/HRS software package was developed for use at DOE facilities, it has direct applicability to the performing of CERCLA Phase I evaluations for any facility contaminated by hazardous waste. The software can perform evaluations using either the modified hazard ranking system methodology developed by DOE/PNL, the hazard ranking system methodology developed by EPA/MITRE Corp., or a combination of the two. This document is a companion manual to the mHRS/HRS user manual. It is intended for the programmer who must maintain the software package and for those interested in the computer implementation. This manual documents the system logic, computer programs, and data files that comprise the package. Hardware and software implementation requirements are discussed. In addition, hand calculations of three sample situations (problems) with associated computer runs used for the verification of program calculations are included.

  7. Modified Hazard Ranking System/Hazard Ranking System for sites with mixed radioactive and hazardous wastes: Software documentation

    International Nuclear Information System (INIS)

    Stenner, R.D.; Peloquin, R.A.; Hawley, K.A.

    1986-11-01

    The mHRS/HRS software package was developed by the Pacific Northwest Laboratory (PNL) under contract with the Department of Energy (DOE) to provide a uniform method for DOE facilities to use in performing their Conservation Environmental Response Compensation and Liability Act (CERCLA) Phase I Modified Hazard Ranking System or Hazard Ranking System evaluations. The program is designed to remove the tedium and potential for error associated with the performing of hand calculations and the interpreting of information on tables and in reference books when performing an evaluation. The software package is designed to operate on a microcomputer (IBM PC, PC/XT, or PC/AT, or a compatible system) using either a dual floppy disk drive or a hard disk storage system. It is written in the dBASE III language and operates using the dBASE III system. Although the mHRS/HRS software package was developed for use at DOE facilities, it has direct applicability to the performing of CERCLA Phase I evaluations for any facility contaminated by hazardous waste. The software can perform evaluations using either the modified hazard ranking system methodology developed by DOE/PNL, the hazard ranking system methodology developed by EPA/MITRE Corp., or a combination of the two. This document is a companion manual to the mHRS/HRS user manual. It is intended for the programmer who must maintain the software package and for those interested in the computer implementation. This manual documents the system logic, computer programs, and data files that comprise the package. Hardware and software implementation requirements are discussed. In addition, hand calculations of three sample situations (problems) with associated computer runs used for the verification of program calculations are included

  8. Strong forward-backward asymmetries in electron emission from overlapping resonance states in fast C3+ on He collisions

    International Nuclear Information System (INIS)

    Yamazaki, Y.; Miller, P.D.; Krause, H.F.; Pepmiller, P.L.; Datz, S.; Sellin, I.A.

    1986-01-01

    Autoionizing electrons from the configuration 1s 2 2pnl produced by transfer and excitation were measured for 2.5 to 5.0 MeV C 3+ + He-gas collision employing the method of zero-degree Auger spectroscopy. The elctron analyzer was operated with an energy resolution of 300 MeV (FWHM), which corresponds to the projectile rest frame energy resolution (approx.40 MeV)

  9. New portable neutron generator for well logging

    International Nuclear Information System (INIS)

    Chicanov, A.E.; Gromov, E. V.; Gulko, V. M.; Izmailov, A. V.

    1994-01-01

    The information about the design, investigation and testing of new well neutron generator for the pulse neutron logging (PNL) is given in this paper. The main physical characteristics of new PNL apparatus are: Neutron flux 2.10 sup 8 n/s ; Pulse frequency>=400 Hz; Diameter= 90 mm; Logging velocity >200 m/h; Number of probes = 2; Resource > 300 h. The generator were provided by gas-filled neutron accelerative tube named NTF-2. The perspective of application and optimization shown PNL apparatus are considered. (author)

  10. GETOUT - a one-dimensional model for groundwater transport of radionuclide decay chains

    International Nuclear Information System (INIS)

    Grundfelt, B.; Elert, M.

    1980-01-01

    The GETOUT-code, originally developed at Batelle Pacific Northwest Laboratories (PNL), was used in the KBS-project to calculate the radionuclide discharges from the repository. The version used in KBS was a translation of the PNL BASIC-language version as by December 1976. In this report a new version, mathematically compatible with the PNL FORTRAN version as by 1979-08-15, is documented. Details are given on the differences between this new version and the version used in the KBS project up to now. (author)

  11. Rotary Mode Core Sample System availability improvement

    International Nuclear Information System (INIS)

    Jenkins, W.W.; Bennett, K.L.; Potter, J.D.; Cross, B.T.; Burkes, J.M.; Rogers, A.C.

    1995-01-01

    The Rotary Mode Core Sample System (RMCSS) is used to obtain stratified samples of the waste deposits in single-shell and double-shell waste tanks at the Hanford Site. The samples are used to characterize the waste in support of ongoing and future waste remediation efforts. Four sampling trucks have been developed to obtain these samples. Truck I was the first in operation and is currently being used to obtain samples where the push mode is appropriate (i.e., no rotation of drill). Truck 2 is similar to truck 1, except for added safety features, and is in operation to obtain samples using either a push mode or rotary drill mode. Trucks 3 and 4 are now being fabricated to be essentially identical to truck 2

  12. 30 CFR 90.208 - Bimonthly sampling.

    Science.gov (United States)

    2010-07-01

    ... MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.208 Bimonthly sampling. (a) Each operator shall take one valid respirable dust sample for... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Bimonthly sampling. 90.208 Section 90.208...

  13. 30 CFR 90.207 - Compliance sampling.

    Science.gov (United States)

    2010-07-01

    ... MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.207 Compliance sampling. (a) The operator shall take five valid respirable dust samples for... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Compliance sampling. 90.207 Section 90.207...

  14. Guidance for establishment and implementation of field sample management programs in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-01-01

    The role of the National Sample Management Program (NSMP) proposed by the Department of Energy's Office of Environmental Management (EM) is to be a resource for EM programs and for local Field Sample Management Programs (FSMPs). It will be a source of information on sample analysis and data collection within the DOE complex. The purpose of this document is to establish the suggested scope of the FSMP activities to be performed under each Operations Office, list the drivers under which the program will operate, define terms and list references. This guidance will apply only to EM sampling and analysis activities associated with project planning, contracting, laboratory selection, sample collection, sample transportation, laboratory analysis and data management

  15. Requested information regarding remote analytical capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Steel, R.T.

    1991-09-01

    This document describes a new method for analysis of cyanide in radioactive waste samples from the Hanford Site. The new assay is designed to increase throughput of samples, reduce waste volumes and decrease radiation exposure to analysts. The system is based on the Lachat Micro-Dist{sup TM} microdistillation system. This document contains the reference and methods manual for this kit, and also the specific PNL lab procedures for using this kit. 6 refs., 20 figs. (MHB)

  16. Whole Genome Sequencing and Multiplex qPCR Methods to Identify Campylobacter jejuni Encoding cst-II or cst-III Sialyltransferase

    Directory of Open Access Journals (Sweden)

    Jason M. Neal-McKinney

    2018-03-01

    Full Text Available Campylobacter jejuni causes more than 2 million cases of gastroenteritis annually in the United States, and is also linked to the autoimmune sequelae Guillan–Barre syndrome (GBS. GBS often results in flaccid paralysis, as the myelin sheaths of nerve cells are degraded by the adaptive immune response. Certain strains of C. jejuni modify their lipooligosaccharide (LOS with the addition of neuraminic acid, resulting in LOS moieties that are structurally similar to gangliosides present on nerve cells. This can trigger GBS in a susceptible host, as antibodies generated against C. jejuni can cross-react with gangliosides, leading to demyelination of nerves and a loss of signal transduction. The goal of this study was to develop a quantitative PCR (qPCR method and use whole genome sequencing data to detect the Campylobactersialyltransferase (cst genes responsible for the addition of neuraminic acid to LOS. The qPCR method was used to screen a library of 89 C. jejuni field samples collected by the Food and Drug Administration Pacific Northwest Lab (PNL as well as clinical isolates transferred to PNL. In silico analysis was used to screen 827 C. jejuni genomes in the FDA GenomeTrakr SRA database. The results indicate that a majority of C. jejuni strains could produce LOS with ganglioside mimicry, as 43.8% of PNL isolates and 46.9% of the GenomeTrakr isolates lacked the cst genes. The methods described in this study can be used by public health laboratories to rapidly determine whether a C. jejuni isolate has the potential to induce GBS. Based on these results, a majority of C. jejuni in the PNL collection and submitted to GenomeTrakr have the potential to produce LOS that mimics human gangliosides.

  17. Qualitative and quantitative analysis of the saponins in Panax notoginseng leaves using ultra-performance liquid chromatography coupled with time-of-flight tandem mass spectrometry and high performance liquid chromatography coupled with UV detector

    Directory of Open Access Journals (Sweden)

    Fang Liu

    2018-04-01

    Full Text Available Background: Panax notoginseng leaves (PNL exhibit extensive activities, but few analytical methods have been established to exclusively determine the dammarane triterpene saponins in PNL. Methods: Ultra-performance liquid chromatography coupled with time-of-flight mass spectrometry (UPLC/Q-TOF MS and HPLC-UV methods were developed for the qualitative and quantitative analysis of ginsenosides in PNL, respectively. Results: Extraction conditions, including solvents and extraction methods, were optimized, which showed that ginsenosides Rc and Rb3, the main components of PNL, are transformed to notoginsenosides Fe and Fd, respectively, in the presence of water, by removing a glucose residue from position C-3 via possible enzymatic hydrolysis. A total of 57 saponins were identified in the methanolic extract of PNL by UPLC/Q-TOF MS. Among them, 19 components were unambiguously characterized by their reference substances. Additionally, seven saponins of PNL—ginsenosides Rb1, Rc, Rb2, and Rb3, and notoginsenosides Fc, Fe, and Fd—were quantified using the HPLC-UV method after extraction with methanol. The separation of analytes, particularly the separation of notoginsenoside Fc and ginsenoside Rc, was achieved on a Zorbax ODS C8 column at a temperature of 35°C. This developed HPLC-UV method provides an adequate linearity (r2>0.999, repeatability (relative standard deviation, RSD < 2.98%, and inter- and intraday variations (RSD < 4.40% with recovery (98.7–106.1% of seven saponins concerned. This validated method was also conducted to determine seven components in 10 batches of PNL. Conclusion: These findings are beneficial to the quality control of PNL and its relevant products. Keywords: ginsenoside transformation, notoginsenoside Fd, notoginsenoside Fe, Panax notoginseng leaves, UPLC/Q-TOF MS

  18. [Ultraminipercutaneous nephrolithotripsy in treating kidney stones].

    Science.gov (United States)

    Martov, A G; Dutov, S V; Andronov, A S

    2016-04-01

    Percutaneous nephrolithotripsy (PNL) is the recommended method of surgical treatment of kidney stones of size greater than 2 cm. Trends in the development of modern urology have been steadily toward less traumatic method to treat nephrolithiasis - minimally invasive PNL. The present work aimed to explore of the possibilities of one of the modern variants of minimally invasive PNL - ultra-mini-PNL in treating nephrolithiasis. The study included 60 patients (mean age 45.6+/-7.2 years) with isolated kidney calculus, up to 2.0 cm or several stones with a total size of up to 2.5 cm. All patients were found to have 77 kidney stones, six of which had a size of 10 mm, 51 had a size of 11-15 mm and 20 had a size of 16-20 mm. 45% of patients had isolated renal pelvic stones and 28.3% had stones in the renal pelvis and lower calyx. All patients underwent ultra-mini-PNL using nephroscope size 7.5 Ch and tube size 12 Fr. The average duration of surgery from the moment of the puncture of the pyelocaliceal system to installing the nephrostomy tube was 65.4 minutes. Complete clearance of stones after single-stage ultra-mini-PNL was observed in 80% of cases. Nephrostomy tube was removed on days 2-3. The average postoperative hospital stay was 5.1 days. The most common complication was postoperative exacerbation of pyelonephritis (13.3% of patients), successfully treated with conservative measures. There were no cases of postoperative bleeding, accompanied by anemia and needed a blood transfusion. Considering high effectiveness and low rate of complications of ultra-mini-PNL, it can be successfully used in treating nephrolithiasis among a wide group of patients.

  19. [Ultrasound guided percutaneous nephrolithotripsy].

    Science.gov (United States)

    Guliev, B G

    2014-01-01

    The study was aimed to the evaluation of the effectiveness and results of ultrasound guided percutaneous nephrolithotripsy (PNL) for the treatment of patients with large stones in renal pelvis. The results of PNL in 138 patients who underwent surgery for kidney stones from 2011 to 2013 were analyzed. Seventy patients (Group 1) underwent surgery with combined ultrasound and radiological guidance, and 68 patients (Group 2)--only with ultrasound guidance. The study included patients with large renal pelvic stones larger than 2.2 cm, requiring the formation of a single laparoscopic approach. Using the comparative analysis, the timing of surgery, the number of intra- and postoperative complications, blood loss and length of stay were evaluated. Percutaneous access was successfully performed in all patients. Postoperative complications (exacerbation of chronic pyelonephritis, gross hematuria) were observed in 14.3% of patients in Group 1 and in 14.7% of patients in Group 2. Bleeding requiring blood transfusion, and injuries of adjacent organs were not registered. Efficacy of PNL in the Group 1 was 95.7%; 3 (4.3%) patients required additional interventions. In Group 2, the effectiveness of PNL was 94.1%, 4 (5.9%) patients additionally underwent extracorporeal lithotripsy. There were no significant differences in the effectiveness of PNL, the volume of blood loss and duration of hospitalization. Ultrasound guided PNL can be performed in large pelvic stones and sufficient expansion of renal cavities, thus reducing radiation exposure of patients and medical staff.

  20. An analysis pipeline for the inference of protein-protein interaction networks

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Ronald C.; Singhal, Mudita; Daly, Don S.; Gilmore, Jason M.; Cannon, William R.; Domico, Kelly O.; White, Amanda M.; Auberry, Deanna L.; Auberry, Kenneth J.; Hooker, Brian S.; Hurst, G. B.; McDermott, Jason E.; McDonald, W. H.; Pelletier, Dale A.; Schmoyer, Denise A.; Wiley, H. S.

    2009-12-01

    An analysis pipeline has been created for deployment of a novel algorithm, the Bayesian Estimator of Protein-Protein Association Probabilities (BEPro), for use in the reconstruction of protein-protein interaction networks. We have combined the Software Environment for BIological Network Inference (SEBINI), an interactive environment for the deployment and testing of network inference algorithms that use high-throughput data, and the Collective Analysis of Biological Interaction Networks (CABIN), software that allows integration and analysis of protein-protein interaction and gene-to-gene regulatory evidence obtained from multiple sources, to allow interactions computed by BEPro to be stored, visualized, and further analyzed. Incorporating BEPro into SEBINI and automatically feeding the resulting inferred network into CABIN, we have created a structured workflow for protein-protein network inference and supplemental analysis from sets of mass spectrometry bait-prey experiment data. SEBINI demo site: https://www.emsl.pnl.gov /SEBINI/ Contact: ronald.taylor@pnl.gov. BEPro is available at http://www.pnl.gov/statistics/BEPro3/index.htm. Contact: ds.daly@pnl.gov. CABIN is available at http://www.sysbio.org/dataresources/cabin.stm. Contact: mudita.singhal@pnl.gov.

  1. Sampling and analysis plan for treatment water and creek water for the Lower East Fork Poplar Creek Operable Unit, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-04-01

    This document provides the Environmental Restoration Program with information about the methodology, organizational structure, quality assurance and health and safety practices to be employed during the water sampling and analysis activities associated with the remediation of the Lower East Fork Poplar Creek Operable Unit during remediation of the National Oceanic and Atmospheric Administration and Bruner sites.

  2. Sampling and analysis plan for treatment water and creek water for the Lower East Fork Poplar Creek Operable Unit, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1996-04-01

    This document provides the Environmental Restoration Program with information about the methodology, organizational structure, quality assurance and health and safety practices to be employed during the water sampling and analysis activities associated with the remediation of the Lower East Fork Poplar Creek Operable Unit during remediation of the National Oceanic and Atmospheric Administration and Bruner sites

  3. Vandenberg Air Force Base integrated resource assessment. Volume 3, Resource assessment

    Energy Technology Data Exchange (ETDEWEB)

    Daellenbach, K.K.; Dagle, J.E.; Dittmer, A.L.; Elliott, D.B.; Halverson, M.A.; Hickman, B.J.; Parker, G.B.; Richman, E.E.; Shankle, S.A.

    1993-06-01

    The US Air Force Space Command (SPACECOM) has tasked the Pacific Northwest Laboratory (PNL), as the lead laboratory supporting the US Department of Energy (DOE) Federal Energy Management Program (FEMP), to identify, evaluate, and assist in acquiring all cost-effective energy projects at Vandenberg Air Force Base (VAFB). This is part of a model program that PNL is designing to support energy-use decisions in the federal sector. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at the SPACECOM VAFB facility located approximately 50 miles northwest of Santa Barbara, California. It is a companion report to Volume 1, Executive Summary, and Volume 2, Baseline Detail. The results of the analysis of EROs are presented in ten common energy end-use categories (e.g., boilers and furnaces, service hot water, and building lighting). In addition, a case study of process loads at Space Launch Complex-4 (SLC-4) is included. A narrative description of each ERO is provided, including information on the installed cost, energy and dollar savings; impacts on operation and maintenance (O and M); and, when applicable, a discussion of energy supply and demand, energy security, and environmental issues. A description of the evaluation methodologies and technical and cost assumptions is also provided for each ERO. Summary tables present the cost-effectiveness of energy end-use equipment before and after the implementation of each ERO and present the results of the life-cycle cost (LCC) analysis indicating the net present value (NPV) and value index (VI) of each ERO. Finally, an appendix includes a summary of an economic analysis case study of the South Vandenberg Power Plant (SVPP) operating scenarios.

  4. Alternating sample changer and an automatic sample changer for liquid scintillation counting of alpha-emitting materials

    International Nuclear Information System (INIS)

    Thorngate, J.H.

    1977-08-01

    Two sample changers are described that were designed for liquid scintillation counting of alpha-emitting samples prepared using solvent-extraction chemistry. One operates manually but changes samples without exposing the photomultiplier tube to light, allowing the high voltage to remain on for improved stability. The other is capable of automatically counting up to 39 samples. An electronic control for the automatic sample changer is also described

  5. Efficient separations and processing crosscutting program: Develop and test sorbents

    International Nuclear Information System (INIS)

    Bray, L.A.

    1995-09-01

    This report summarizes work performed during FY 1995 under the task open-quotes Develop and Test Sorbents,close quotes the purpose of which is to develop high-capacity, selective solid extractants to recover cesium, strontium, and technetium from nuclear wastes. This work is being done for the Efficient Separations and Processing Crosscutting Program (ESP), operated by the U.S. Department of Energy's Office of Environmental Management's Office of Technology Development. The task is under the direction of staff at Pacific Northwest Laboratory (PNL) with key participation from industrial and university staff at 3M, St. Paul, Minnesota; IBC Advanced Technologies, Inc., American Forks, Utah; AlliedSignal, Inc., Des Plaines, Illinois, and Texas A ampersand M University, College Station, Texas. 3M and IBC are responsible for ligand and membrane technology development; AlliedSignal and Texas A ampersand M are developing sodium titanate powders; and PNL is testing the materials developed by the industry/university team members. Major accomplishments for FY 1995 are summarized in this report

  6. Two-neutrino double-beta decay

    International Nuclear Information System (INIS)

    Guerard, O.

    1992-01-01

    Two previous independent reports of 2νββ-decay by the ITEP-YPI collaboration, T 2ν 1/2 = (9 ± 1) x 10 20 yr (1σ), were confirmed using a 0.25 Kg Ge(Li) detector isotopically enriched to 86% in 76 Ge. The detector was operated in the PNL-USC ultralow background facility in the Homestake gold mine for 168 days. Following a single correction to the data, a spectrum resembling that of the earlier PNL-USC experiment, with about the same intensity per 76 Ge atom, per year, was observed with a measured half life of T 2ν 1/2 = (9.2 +0.7 -0.2 ) x 10 21 y (90% C.L.), by observing the 590.76 and 539.53 keV gamma rays emitted in the 0 + 1 → 2 + → 0 + de-excitation cascade. A review of the most relevant nuclear structure calculations is given, and their predictions are compared to the measurements from the present two experiments

  7. Basis for snubber aging research: Nuclear Plant Aging Research Program

    International Nuclear Information System (INIS)

    Brown, D.P.; Palmer, G.R.; Werry, E.V.; Blahnik, D.E.

    1990-01-01

    This report describes a research plan to address the safety concerns of aging in snubbers used on piping and equipment in commercial nuclear power plants. The work is to be performed under Phase 2 of the Snubber Aging Study of the Nuclear Plant Aging Research Program of the US Nuclear Regulatory Commission with the Pacific Northwest Laboratory (PNL) as the prime contractor. Research conducted by PNL under Phase 1 provided an initial assessment of snubber operating experience and was primarily based on a review of licensee event reports. The work proposed is an extension of Phase 1 and includes research at nuclear power plants and in test laboratories. Included is technical background on the design and use of snubbers in commercial nuclear power applications; the primary failure modes of both hydraulic and mechanical snubbers are discussed. The anticipated safety, technical, and regulatory benefits of the work, along with concerns of the NRC and the utilities, are also described. 21 refs., 7 figs., 1 tab

  8. Laboratory work in support of West Valley glass development

    International Nuclear Information System (INIS)

    Bunnell, L.R.

    1988-05-01

    Over the past six years, Pacific Northwest Laboratory (PNL) has conducted several studies in support of waste glass composition development and testing of glass compositions suitable for immobilizing the nuclear wastes stored at West Valley, New York. As a result of pilot-scale testing conducted by PNL, the glass composition was changed from that originally recommended in response to changes in the waste stream, and several processing-related problems were discovered. These problems were solved, or sufficiently addressed to determine their likely effect on the glass melting operations to be conducted at West Valley. This report describes the development of the waste glass composition, WV-205, and discusses solutions to processing problems such as foaming and insoluble sludges, as well as other issues such as effects of feed variations on processing of the resulting glass. An evaluation of the WV-205 glass from a repository perspective is included in the appendix to this report

  9. Maintaining continuity of knowledge on safeguards samples

    International Nuclear Information System (INIS)

    Franssen, F.; Islam, A.B.M.N.; Sonnier, C.; Schoeneman, J.L.; Baumann, M.

    1992-01-01

    The conclusions of the vulnerability test on VOPAN (verification of Operator's Analysis) as conducted at Safeguards Analytical Laboratory (ASA) at Seibersdorf, Austria in October 1990 and documented in STR-266, indicate that ''whenever samples are taken for safeguards purposes extreme care must be taken to ensure that they have not been interfered with during the sample taking, transportation, storage or sample preparation process.'' Indeed there exist a number of possibilities to alter the content of a safeguards sample vial from the moment of sampling up to the arrival of the treated (or untreated) sample at SAL. The time lapse between these two events can range from a few days up to months. The sample history over this period can be subdivided into three main sub-periods: (1) the period from when the sampling activities are commenced up to the treatment in the operator's laboratory, (2) during treatment of samples in the operator's laboratory, and finally, (3) the period between that treatment and the arrival of the sample at SAL. A combined effort between the Agency and the United States Support Program to the Agency (POTAS) has resulted in two active tasks and one proposed task to investigate improving the maintenance of continuity of knowledge on safeguards samples during the entire period of their existence. This paper describes the use of the Sample Vial Secure Container (SVSC), of the Authenticated Secure Container System (ASCS), and of the Secure Container for Storage and Transportation of samples (SCST) to guarantee that a representative portion of the solution sample will be received at SAL

  10. Shielded scanning electron microscope for radioactive samples

    International Nuclear Information System (INIS)

    Crouse, R.S.; Parsley, W.B.

    1977-01-01

    A small commercial SEM had been successfully shielded for examining radioactive materials transferred directly from a remote handling facility. Relatively minor mechanical modifications were required to achieve excellent operation. Two inches of steel provide adequate shielding for most samples encountered. However, samples reading 75 rad/hr γ have been examined by adding extra shielding in the form of tungsten sample holders and external lead shadow shields. Some degradation of secondary electron imaging was seen but was adequately compensated for by changing operating conditions

  11. Hypothesis Sampling Systems among Preoperational and Concrete Operational Kindergarten Children

    Science.gov (United States)

    Gholson, Barry; And Others

    1976-01-01

    Preoperational and concrete operational kindergarten children received stimulus differentiation training, either with or without feedback, and then a series of discrimination learning problems in which a blank trial probe was used to detect a child's hypothesis after each feedback trial. Piagetian stage theory requires elaboration to account…

  12. Heterodyne displacement interferometer, insensitive for input polarization

    NARCIS (Netherlands)

    Meskers, A.J.H.; Spronck, J.W.; Munnig Schmidt, R.H.

    2014-01-01

    Periodic nonlinearity (PNL) in displacement interferometers is a systematic error source that limits measurement accuracy. The PNL of coaxial heterodyne interferometers is highly influenced by the polarization state and orientation of the source frequencies. In this Letter, we investigate this error

  13. Effect of Supine vs Prone Position on Outcomes of Percutaneous Nephrolithotomy in Staghorn Calculi: Results From the Clinical Research Office of the Endourology Society Study

    DEFF Research Database (Denmark)

    Astroza, Gaston; Lipkin, Michael; Neisius, Andreas

    2013-01-01

    To analyze the effect of patient positioning on outcomes of percutaneous nephrolithotomy (PNL) among patients with staghorn stones. The choice of optimal position for these patients undergoing PNL remains challenging. No previous studies exclusively addressing this point have been performed....

  14. Material sampling for rotor evaluation

    International Nuclear Information System (INIS)

    Mercaldi, D.; Parker, J.

    1990-01-01

    Decisions regarding continued operation of aging rotating machinery must often be made without adequate knowledge of rotor material conditions. Physical specimens of the material are not generally available due to lack of an appropriate sampling technique or the high cost and inconvenience of obtaining such samples. This is despite the fact that examination of such samples may be critical to effectively assess the degradation of mechanical properties of the components in service or to permit detailed examination of microstructure and surface flaws. Such information permits a reduction in the uncertainty of remaining life estimates for turbine rotors to avoid unnecessarily premature and costly rotor retirement decisions. This paper describes the operation and use of a recently developed material sampling device which machines and recovers an undeformed specimen from the surface of rotor bores or other components for metallurgical analysis. The removal of the thin, wafer-like sample has a negligible effect on the structural integrity of these components, due to the geometry and smooth surface finish of the resulting shallow depression. Samples measuring approximately 0.03 to 0.1 inches (0.76 to 2.5 mm) thick by 0.5 to 1.0 inch (1.3 to 2.5 cm) in diameter can be removed without mechanical deformation or thermal degradation of the sample or the remaining component material. The device is operated remotely from a control console and can be used externally or internally on any surface for which there is at least a three inch (7.6 cm) working clearance. Application of the device in two case studies of turbine-generator evaluations are presented

  15. Final report, Ames Mobile Laboratory Project: The development and operation of instrumentation in a mobile laboratory for in situ, real-time screening and characterization of soils using the laser ablation sampling technique

    International Nuclear Information System (INIS)

    Anderson, M.S.; Braymen, S.D.

    1995-01-01

    The main focus of the Ames Laboratory's Technology Integration Program, TIP, from May 1991 through December 1994 was the development, fabrication, and demonstration of a mobile instrumentation laboratory incorporating rapid in situ sampling systems for safe, rapid, and cost effective soil screening/characterization. The Mobile Demonstration Laboratory for Environmental Screening Technologies, MDLEST, containing the analysis instrumentation, along with surface and subsurface sampling probe prototypes employing the laser ablation sampling technique were chosen to satisfy the particular surface and subsurface soil characterization needs of the various Department of Energy facilities for determining the extent of heavy metal and radionuclide contamination. The MDLEST, a 44 foot long 5th wheel trailer, is easily configured for the analysis instrumentation and sampling system required for the particular site work. This mobile laboratory contains all of the utilities needed to satisfy the operating requirements of the various instrumentation installed. These utilities include, an electric generator, a chilled water system, process gases, a heating/air conditioning system, and computer monitoring and automatic operating systems. Once the MDLEST arrives at the job site, the instrumentation is aligned and calibration is completed, sampling and analysis operations begin. The sample is acquired, analyzed and the results reported in as little as 10 minutes. The surface sampling probe is used in two modes to acquire samples for analysis. It is either set directly on the ground over the site to be sampled, in situ sampling, or in a special fixture used for calibrating the sampling analysis system with standard soil samples, having the samples brought to the MDLEST. The surface sampling probe was used to in situ sample a flat concrete surface (nondestructively) with the ablated sample being analyzed by the instrumentation in the MDLEST

  16. FACSIM/MRS (Monitored Retrievable Storage)-2: Storage and shipping model documentation and user's guide

    Energy Technology Data Exchange (ETDEWEB)

    Huber, H.D.; Chockie, A.D.; Hostick, C.J.; Otis, P.T.; Sovers, R.A.

    1987-06-01

    The Pacific Northwest Laboratory (PNL) has developed a stochastic computer model, FACSIM/MRS, to assist in assessing the operational performance of the Monitored Retrievable Storage (MRS) waste-handling facility. This report provides the documentation and user's guide for FACSIM/MRS-2, which is also referred to as the back-end model. The FACSIM/MRS-2 model simulates the MRS storage and shipping operations, which include handling canistered spent fuel and secondary waste in the shielded canyon cells, in onsite yard storage, and in repository shipping cask loading areas.

  17. FACSIM/MRS [Monitored Retrievable Storage]-2: Storage and shipping model documentation and user's guide

    International Nuclear Information System (INIS)

    Huber, H.D.; Chockie, A.D.; Hostick, C.J.; Otis, P.T.; Sovers, R.A.

    1987-06-01

    The Pacific Northwest Laboratory (PNL) has developed a stochastic computer model, FACSIM/MRS, to assist in assessing the operational performance of the Monitored Retrievable Storage (MRS) waste-handling facility. This report provides the documentation and user's guide for FACSIM/MRS-2, which is also referred to as the back-end model. The FACSIM/MRS-2 model simulates the MRS storage and shipping operations, which include handling canistered spent fuel and secondary waste in the shielded canyon cells, in onsite yard storage, and in repository shipping cask loading areas

  18. Eigenvalue sensitivity of sampled time systems operating in closed loop

    Science.gov (United States)

    Bernal, Dionisio

    2018-05-01

    The use of feedback to create closed-loop eigenstructures with high sensitivity has received some attention in the Structural Health Monitoring field. Although practical implementation is necessarily digital, and thus in sampled time, work thus far has center on the continuous time framework, both in design and in checking performance. It is shown in this paper that the performance in discrete time, at typical sampling rates, can differ notably from that anticipated in the continuous time formulation and that discrepancies can be particularly large on the real part of the eigenvalue sensitivities; a consequence being important error on the (linear estimate) of the level of damage at which closed-loop stability is lost. As one anticipates, explicit consideration of the sampling rate poses no special difficulties in the closed-loop eigenstructure design and the relevant expressions are developed in the paper, including a formula for the efficient evaluation of the derivative of the matrix exponential based on the theory of complex perturbations. The paper presents an easily reproduced numerical example showing the level of error that can result when the discrete time implementation of the controller is not considered.

  19. Green River air quality model development: meteorological and tracer data, July/August 1982 field study in Brush Valley, Colorado

    Energy Technology Data Exchange (ETDEWEB)

    Whiteman, C.D.; Lee, R.N.; Orgill, M.M.; Zak, B.D.

    1984-06-01

    Meteorological and atmospheric tracer studies were conducted during a 3-week period in July and August of 1982 in the Brush Creek Valley of northwestern Colorado. The objective of the field experiments was to obtain data to evaluate a model, called VALMET, developed at PNL to predict dispersion of air pollutants released from an elevated stack located within a deep mountain valley in the post-sunrise temperature inversion breakup period. Three tracer experiments were conducted in the valley during the 2-week period. In these experiments, sulfur hexafluoride (SF/sub 6/) was released from a height of approximately 100 m, beginning before sunrise and continuing until the nocturnal down-valley winds reversed several hours after sunrise. Dispersion of the sulfur hexafluoride after release was evaluated by measuring SF/sub 6/ concentrations in ambient air samples taken from sampling devices operated within the valley up to about 8 km down valley from the source. An instrumented research aircraft was also used to measure concentrations in and above the valley. Tracer samples were collected using a network of radio-controlled bag sampling stations, two manually operated gas chromatographs, a continuous SF/sub 6/ monitor, and a vertical SF/sub 6/ profiler. In addition, basic meteorological data were collected during the tracer experiments. Frequent profiles of vertical wind and temperature structure were obtained with tethered balloons operated at the release site and at a site 7.7 km down the valley from the release site. 10 references, 63 figures, 50 tables.

  20. Rational choice of a minimally invasive method of treatment in uncomplicated nephrolithiasis with kidney calculi from 1.0 to 2.5 cm

    Directory of Open Access Journals (Sweden)

    А. І. Sagalevich

    2018-02-01

    Full Text Available Study purpose – to improve the solitary nephrolithiasis treatment effectiveness by determining the optimal conditions for ESWL or mini PNL application in the treatment of kidney calculi 1.0 to2.5 cm in size. Patients and methods. A comparative analysis of the results of minimally invasive methods application for nephrolithiasis treatment was performed in 210 patients treated with mini PNL (the group I and 190 patients treated with ESWL (the group II. Patients with calculi more than 1.5 cm predominated in the group of mini PNL and with calculi less than 1.5 cm – in the ESWL group. The number of patients with calculi 1.5–2.0 cm in both groups was the same: 24.3 % and 24.2 % (P > 0.05. Results. It was noted that the calculi destruction effectiveness after 1–4 or more sessions of ESWL took place in 182 patients (95.8 %. At the same time, an increase in the mean density of calculi above 600 HU caused reduction (P < 0.001 of the primary ESWL session efficiency almost twofold. When performing the 221 mPNL, 97.1 % of the patients required one surgical treatment. The number of complications (bleeding, attack of pyelonephritis in the group II was insignificantly higher in contrast to the group I – 26 (12.3 % and 45 (14.1 %, respectively (P < 0.05. The stone-free status (up to one month was noted in 62.6 % of patients after the completion of ESWL sessions that increases the risk of nephrolithiasis recurrence from 37.4 %. In treatment with mPNL, the stone-free status reached 97.1 % (P < 0.001, and in repeated mPNL applying in 2.8 % of cases – 100 %. The mean clinic postoperative treatment periods in the group I were lower in contrast to patients of the group II – 3.0 ± 1.5 and 12.5 ± 3.6, respectively (P < 0.001. Conclusions. This comparative analysis of features and results of uncomplicated nephrolithiasis with mPNL and ESWL treatment indicates that mPNL is the most preferred method for kidney calculi 1.0 to2.5 cm and more in size treatment.

  1. Solid Waste Projection Model: Model user's guide

    International Nuclear Information System (INIS)

    Stiles, D.L.; Crow, V.L.

    1990-08-01

    The Solid Waste Projection Model (SWPM) system is an analytical tool developed by Pacific Northwest Laboratory (PNL) for Westinghouse Hanford company (WHC) specifically to address solid waste management issues at the Hanford Central Waste Complex (HCWC). This document, one of six documents supporting the SWPM system, contains a description of the system and instructions for preparing to use SWPM and operating Version 1 of the model. 4 figs., 1 tab

  2. Master schedule for CY-1979 Hanford environmental surveillance routine program

    International Nuclear Information System (INIS)

    Blumer, P.J.; Houston, J.R.; Eddy, P.A.

    1978-12-01

    The current schedule of data collection for the routine environmental surveillance program at the Hanford Site, as conducted by the Environmental Evaluation Section of Battelle, Pacific Northwest Laboratory for the Department of Energy (DOE), is given. Modifications to the schedule are made during the year and special areas of study, usually of short duration, are not scheduled. The environmental surveillance program objectives are to evaluate the levels of radioactive and nonradioactive pollutants in the Hanford environs, and to monitor Hanford operations for compliance with applicable environmental criteria and Washington State Water Quality Standards. Air quality data are obtained in a separate program administered by the Hanford Environmental Health Foundation. The collection schedule for potable water is shown but it is not part of the routine environmental surveillance program. Water quality data for Hanford Site potable water systems are published each year by the Hanford Environmental Health Foundation. The data collected are available in routine reports issued by the Environmental Evaluations staff. Groundwater data and evaluation are reported in the series, ''Radiological Status of the Groundwater Beneath the Hanford Project for...,'' the latest issue being PNL-2624 for CY-1977. Data from locations within the plant boundaries are presented in the annual ''Environmental Status of the Hanford Site for...'' report series, the most recent report being PNL-2677 for 1977. Data from offsite locations are presented in the annual ''Environmental Surveillance at Hanford for...'' series of reports, the latest being PNL-2614 for 1977

  3. Evaluation of strategies for severe accident prevention and mitigation

    International Nuclear Information System (INIS)

    Tokarz, R.

    1989-01-01

    The NRC is planning to establish regulatory oversight on severe accident management capability in the US nuclear reactor industry. Accident management includes certain preparatory and recovery measures that can be taken by the plant operating and technical personnel to prevent or mitigate the consequences of a severe accident. Following an initiating event, accident management strategies include measures to (1) prevent core damage, (2) arrest the core damage if it begins and retain the core inside the vessel, (3) maintain containment integrity if the vessel is breached, and (4) minimize offsite releases. Objectives of the NRC Severe Accident Management Program are to assure that technically sound strategies are identified and guidance to implement these strategies is provided to utilities. This paper will describe work performed to date by Pacific Northwest Laboratory (PNL) and Battelle Memorial Institute (BMI) relative to severe accident strategy evaluation, as well as work to be performed and expected results. Working with Brookhaven National Laboratory, PNL evaluated a series of NRC suggested accident management strategies. The evaluation of these strategies was divided between PNL and Brookhaven National Laboratory and a similar paper will be presented by Brookhaven regarding their strategy evaluation. This paper will stress the overall safety issues related to the research and emphasize the strategies that are applicable to major safety issues. The relationship of these research activities to other projects is discussed, as well as planning for future changes in the direction of work to be undertaken

  4. Robins Air Force Base integrated resource assessment. Volume 3, Resource assessment

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, G.P.; Keller, J.M.; Stucky, D.J.; Wahlstrom, R.R.; Larson, L.L.

    1993-10-01

    The US Air Force Materiel Command (AFMC) has tasked the US Department of Energy (DOE) Federal Energy Management Program (FEMP), supported by the Pacific Northwest Laboratory (PNL), to identify, evaluate, and assist in acquiring all cost-effective energy projects at Robins Air Force Base (AFB). This is part of a model program that PNL is designing to support energy-use decisions in the federal sector. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at the AFMC Robins AFB facility located approximately 15 miles south of Macon, Georgia. It is a companion report to Volume 1, Executive Summary, and Volume 2, Baseline Detail. The results of the analyses of EROs are presented in 13 common energy end-use categories (e.g., boilers and furnaces, service hot water, and building lighting). A narrative-description of each ERO is provided, including information on the installed cost, energy and dollar savings; impacts on operation and maintenance (O&M); and, when applicable, a discussion of energy supply and demand, energy security, and environmental issues. A description of the evaluation methodologies and technical and cost assumptions is also provided for each ERO. Summary tables present the cost-effectiveness of energy end-use equipment before and after the implementation of each ERO and present the results of the life-cycle cost (LCC) analysis indicating the net present value (NPV) and savings to investment ratio (SIR) of each ERO.

  5. The Factors That Effects Hemorrhage in Percutaneous Nephrolitotomy

    Directory of Open Access Journals (Sweden)

    Fatih Duz

    2014-03-01

    Full Text Available Aim: Today, PNL has become primary treatment alternative in multiple or large kidney stones where ESWL treatment has failed. In our study, we have analyzed the facts that affect hemorrhage in PNL surgeries. Material and Method: Between March 2008 and December 2009, 204 patient%u2019s histories who had undergone percutaneous nephrolithotomy surgery in Izmir Bozyaka Training & Research Hospital, Urology Department were analyzed retrospectively. The patients were assembled under four groups according to the effect of some factors related to stone (size and localization, operation (number and localization of the entrances and the effects of PNL hemorrhage between these groups was investigated. Results: Of the 204 patients undergoing percutaneous nephrolithotomy, 76 were female, 128 were male, with an average age of 46.9±14.2 (18-80. The preoperation and postoperation Hb differences of the 176 patients whose stone load was less than 1000 mm2 and 28 patients whose stone load was over 1000 m2 were compared, yielding no statistically significant difference (p=0.942. Also no statistically significant difference was observed with regard to stone type, number of entries and percutaneous entry location. Discussion: In our study, it has been observed the size and localization of the stone is not an independent factor that affects the hemorrage itself. And also it has been observed that number and localization of entrances are not an independent factor that affecting haemorrhage.

  6. Pacific Northwest Laboratory Maintenance Implementation plan

    International Nuclear Information System (INIS)

    Bright, J.D.

    1992-06-01

    This Maintenance Implementation plan has been developed for Pacific Northwest Laboratory's (PNL) Nuclear Facilities: 306W, 324, 325, 327 and 329NMF. It is based on a graded approach, self-assessment of the existing maintenance program(s) per the requirements specified by US Department of Energy (DOE) Order 4330.4A, Chapter II, Change number-sign 3. The results of this assessment were evaluated to determine needed improvements in PNL Craft Services' current maintenance program. The objective of this implementation plan is to provide baseline information for compliance to the DOE 4330.4A, and for needed improvements. The prime consideration in applying a graded approach to the Order has been to maintain safe and reliable operations, environmental compliance, safeguards and security, programmatic mission, facility preservation, and/or other facility-specific requirements. Using the results of the self-assessment, PNL has selected nine of the 18 elements of the Maintenance Program defined by DOE Order 4330.4A for improvement. The elements selected for improvement are Training and Qualification of Maintenance Personnel; Maintenance Procedures; Planning, Scheduling, and Coordination of Maintenance; Control of Maintenance Activities; Post-Maintenance Testing; Facility Condition Inspection; Management Involvement; Maintenance History; and Additional Maintenance Requirements. Based upon graded approach and current funding, those elements considered most important have been selected as goals for earliest compliance. Commitment dates for these elements have been established for compliance. The remaining elements of noncompliance will be targeted for implementation during later budget periods

  7. Factors Affecting the Success Rate of Percutaneous Nephrolithotomy in Paediatric Patients

    Directory of Open Access Journals (Sweden)

    Hikmat Jabrayilov

    2018-03-01

    Full Text Available In this study, we aimed to determine factors affecting the success rate of percutaneous nephrolithotomy (PNL in children. The series consisted of 41 consecutive children operated on by the same surgical team for renal calculi with PNL between June 2002 and May 2015 in our institution. A single calyx or pelvic stone was described as simple, while calculi located in more than one location (calyx and pelvis or more than one calices or staghorn stones were described as complex. The procedure was deemed successful if the patient was completely stone-free (SF or had residual fragments <4 mm. Thirty-four patients were found to be SF or had residual fragments <4 mm on the postoperative first day, thus the success rate was 82.9%. In complex stones, the success rate was significantly lower (45.5% than simple stones (96.7% (p < 0.001. The grade of hydronephrosis (Grade 0–1 vs. Grade 2–3 also had a negative impact on the success, with rates of 92.6% vs. 64.3%, respectively (p = 0.022. Previous urological procedure history on the same side yielded a success rate of 58.3%, whereas the success rate in the primary patients was 93.1% (p < 0.001. The localization of the stone (complex vs. simple, degree of hydronephrosis, and history of previous urological procedures were found to be the factors that affected the success of the paediatric PNL.

  8. Safety of percutaneous nephrolithotomy in patients on chronic anticoagulant or antiplatelet therapy.

    Science.gov (United States)

    Fernández-Baltar, C; Pérez-Fentes, D; Sánchez-García, J F; García-Freire, C

    2018-01-22

    In developed countries, the incidence of cardiovascular disease is increasing, therefore, anticoagulant and antiplatelet drugs are a widespread treatment nowadays. Percutaneous nephrolithotomy (PNL) is the first-line treatment for large or complex stones (> 2 cm) and remains an alternative for the smaller ones. The objective of this study is to analyze whether PNL surgery is a safe procedure in patients under a treatment discontinuation protocol for anticoagulant or antiplatelet therapies. We retrospectively studied 301 patients who underwent PNL in our hospital between 2008 and 2016 and identified 46 patients on chronic antiplatelet or anticoagulation treatment. With respect to PNL outcomes, the stone-free rate was similar (78 vs 74%, p = 0.762) in both groups, without any significant differences in the overall postoperative complications (17 vs 26%, p = 0.203). The incidence of hemorrhagic complications was similar between groups (12 vs 9%, p = 0.492), as demonstrated by the mean drop in hemoglobin (Hb), which was comparable in both cohorts (2.2 ± 1.3 vs 2.0 ± 1.4 p = 0.270) and the blood transfusion rate (14% in group A and 8% in group B, p = 0.205). No thromboembolic events were found within the year after the PNL procedure. PNL is a safe and effective intervention in patients under a treatment discontinuation protocol for anticoagulant or antiplatelet therapies. Although our study demonstrates the feasibility of this protocol, new scientific evidence aims to stratify the thromboembolic and bleeding risk of each patient to individualize the perioperative management thereafter.

  9. Pacific Northwest Laboratory: Director`s overview of research performed for DOE Office of Health And Environmental Research

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-06-01

    A significant portion of the research undertaken at Pacific Northwest Laboratory (PNL) is focused on the strategic programs of the US Department of Energy`s (DOE) Office of Health and Environmental Research (OHER). These programs, which include Environmental Processes (Subsurface Science, Ecosystem Function and Response, and Atmospheric Chemistry), Global Change (Climate Change, Environmental Vulnerability, and Integrated Assessments), Biotechnology (Human Genome and Structural Biology), and Health (Health Effects and Medical Applications), have been established by OHER to support DOE business areas in science and technology and environmental quality. PNL uses a set of critical capabilities based on the Laboratory`s research facilities and the scientific and technological expertise of its staff to help OHER achieve its programmatic research goals. Integration of these capabilities across the Laboratory enables PNL to assemble multidisciplinary research teams that are highly effective in addressing the complex scientific and technical issues associated with OHER-sponsored research. PNL research efforts increasingly are focused on complex environmental and health problems that require multidisciplinary teams to address the multitude of time and spatial scales found in health and environmental research. PNL is currently engaged in research in the following areas for these OHER Divisions: Environmental Sciences -- atmospheric radiation monitoring, climate modeling, carbon cycle, atmospheric chemistry, ecological research, subsurface sciences, bioremediation, and environmental molecular sciences; Health Effects and Life Sciences -- cell/molecular biology, and biotechnology; Medical Applications and Biophysical Research -- analytical technology, and radiological and chemical physics. PNL`s contributions to OHER strategic research programs are described in this report.

  10. Advanced Neutron Radiographic Equipment within the US Army

    Science.gov (United States)

    2014-01-29

    The first of the two new neutron generators developed for ARDEC was built and delivered by Phoenix Nuclear Labs ( PNL ) located in Madison, WI...PRELIMINARY NEUTRON RADIOGRAPHS AND RESULTS During the hardware and software testing of the PNL neutron generator several test shots were

  11. Soil type influences the sensitivity of nutrient dynamics to changes in atmospheric CO2

    Science.gov (United States)

    Numerous studies have indicated that increases in atmospheric CO2 have the potential to decrease nitrogen availability through the process of progressive nitrogen limitation (PNL). The timing and magnitude of PNL in field experiments is varied due to numerous ecosystem processes. Here we examined ...

  12. DWPF liquid sample station: Status of equipment development

    International Nuclear Information System (INIS)

    Caplan, J.R.

    1987-01-01

    This report summarizes operating experience and equipment status of the DWPF liquid sample cell. Operation hours to date, results of equipment inspections and problems encountered and their solutions are discussed. An equipment and instrumentation status updating DPST-85-592, DWPF LIQUID SAMPLE CELL MOCK-UP, is presented. Remaining development items are also outlined

  13. Incidence of retrorenal colon during percutaneous nephrolithotomy

    Directory of Open Access Journals (Sweden)

    Mehmet Balasar

    2015-04-01

    Full Text Available Objective The aim of this study was to investigate retrorenal colon incidence in percutaneous nephrolithotomy (PNL interventions made in our clinic. Materials and Methods Clinical data of 804 PNL patients, accumulated over a 7 year period (2006-2012, was surveyed. The patient files were reviewed retrospectively, and only those who had abdominal computed tomography (CT images before PNL intervention were included in the study. In the CT images, the position of both the ascending and descending colon in relation to the right and left kidneys were evaluated. Results According to our hospital reports, 394 patients with CT images were included in the present study 27 patients (6.9% had retrorenal colon, of which 18 (4.6% were on the left side, 4 (1.0% on the right side and 5 (1.3% had bilateral retrorenal colons. Colonic perforation complication was seen only in two patients and the colonic perforation rate was 0.3%. These two cases had no CT images. Conclusions PNL, in the process of becoming the standard treatment modality, is a safe and reliable technique for renal stone treatment. Colonic injury should be taken into consideration during PNL interventions of the lower pole of the kidney (especially on the left side due to the location of retrorenal colon.

  14. Summary of radiological monitoring of Columbia River water along the Hanford Reach, 1980 through 1989

    International Nuclear Information System (INIS)

    Dirkes, R.L.

    1994-02-01

    The Surface Environmental Surveillance Project (SESP) is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE) at the Hanford Site in southeastern Washington State. The Columbia River monitoring program, conducted as part of the SESP, provides a historical record of contaminant concentrations in the river attributable to natural causes, worldwide fallout, and operations conducted at the Hanford Site. In addition to ongoing monitoring, special studies are conducted periodically to enhance the understanding of the transport and fate of contaminants in the river. The Columbia River monitoring program includes sampling of river water, river sediment, river-bank springs entering the river, and various types of aquatic biota found in or along the river. These samples are analyzed for radiological constituents and a wide range of chemical parameters. This report describes the water sampling component of the overall Columbia River monitoring program conducted during the years 1980 through 1989 and summarizes the radiological results generated through the program during this time period. The only radionuclides found in the river that were consistently influenced by Hanford were tritium and iodine-129. Strontium-90 and uranium, also attributable to Hanford operations, were present in localized areas within the river near ground-water discharge points; however, these contaminants are quickly dispersed within the river to concentrations similar to background

  15. 30 CFR 71.201 - Sampling; general requirements.

    Science.gov (United States)

    2010-07-01

    ... MINES Sampling Procedures § 71.201 Sampling; general requirements. (a) Each operator shall take... required by this part with a sampling device approved by the Secretary and the Secretary of Health and Human Services under part 74 (Coal Mine Dust Personal Sampler Units) of this title. (b) Sampling devices...

  16. Sampling or gambling

    Energy Technology Data Exchange (ETDEWEB)

    Gy, P.M.

    1981-12-01

    Sampling can be compared to no other technique. A mechanical sampler must above all be selected according to its aptitude for supressing or reducing all components of the sampling error. Sampling is said to be correct when it gives all elements making up the batch of matter submitted to sampling an uniform probability of being selected. A sampler must be correctly designed, built, installed, operated and maintained. When the conditions of sampling correctness are not strictly respected, the sampling error can no longer be controlled and can, unknown to the user, be unacceptably large: the sample is no longer representative. The implementation of an incorrect sampler is a form of gambling and this paper intends to show that at this game the user is nearly always the loser in the long run. The users' and the manufacturers' interests may diverge and the standards which should safeguard the users' interests very often fail to do so by tolerating or even recommending incorrect techniques such as the implementation of too narrow cutters traveling too fast through the stream to be sampled.

  17. PAVENET OS: A Compact Hard Real-Time Operating System for Precise Sampling in Wireless Sensor Networks

    Science.gov (United States)

    Saruwatari, Shunsuke; Suzuki, Makoto; Morikawa, Hiroyuki

    The paper shows a compact hard real-time operating system for wireless sensor nodes called PAVENET OS. PAVENET OS provides hybrid multithreading: preemptive multithreading and cooperative multithreading. Both of the multithreading are optimized for two kinds of tasks on wireless sensor networks, and those are real-time tasks and best-effort ones. PAVENET OS can efficiently perform hard real-time tasks that cannot be performed by TinyOS. The paper demonstrates the hybrid multithreading realizes compactness and low overheads, which are comparable to those of TinyOS, through quantitative evaluation. The evaluation results show PAVENET OS performs 100 Hz sensor sampling with 0.01% jitter while performing wireless communication tasks, whereas optimized TinyOS has 0.62% jitter. In addition, PAVENET OS has a small footprint and low overheads (minimum RAM size: 29 bytes, minimum ROM size: 490 bytes, minimum task switch time: 23 cycles).

  18. Linear models for airborne-laser-scanning-based operational forest inventory with small field sample size and highly correlated LiDAR data

    Science.gov (United States)

    Junttila, Virpi; Kauranne, Tuomo; Finley, Andrew O.; Bradford, John B.

    2015-01-01

    Modern operational forest inventory often uses remotely sensed data that cover the whole inventory area to produce spatially explicit estimates of forest properties through statistical models. The data obtained by airborne light detection and ranging (LiDAR) correlate well with many forest inventory variables, such as the tree height, the timber volume, and the biomass. To construct an accurate model over thousands of hectares, LiDAR data must be supplemented with several hundred field sample measurements of forest inventory variables. This can be costly and time consuming. Different LiDAR-data-based and spatial-data-based sampling designs can reduce the number of field sample plots needed. However, problems arising from the features of the LiDAR data, such as a large number of predictors compared with the sample size (overfitting) or a strong correlation among predictors (multicollinearity), may decrease the accuracy and precision of the estimates and predictions. To overcome these problems, a Bayesian linear model with the singular value decomposition of predictors, combined with regularization, is proposed. The model performance in predicting different forest inventory variables is verified in ten inventory areas from two continents, where the number of field sample plots is reduced using different sampling designs. The results show that, with an appropriate field plot selection strategy and the proposed linear model, the total relative error of the predicted forest inventory variables is only 5%–15% larger using 50 field sample plots than the error of a linear model estimated with several hundred field sample plots when we sum up the error due to both the model noise variance and the model’s lack of fit.

  19. SHINE Tritium Nozzle Design: Activity 6, Task 1 Report

    Energy Technology Data Exchange (ETDEWEB)

    Okhuysen, Brett S. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pulliam, Elias Noel [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-05

    In FY14, we studied the qualitative and quantitative behavior of a SHINE/PNL tritium nozzle under varying operating conditions. The result is an understanding of the nozzle’s performance in terms of important flow features that manifest themselves under different parametric profiles. In FY15, we will consider nozzle design with a focus on nozzle geometry and integration. From FY14 work, we will understand how the SHINE/PNL nozzle behaves under different operating scenarios. The first task for FY15 is to evaluate the FY14 model as a predictor of the actual flow. Considering different geometries is more time-intensive than parameter studies, therefore we recommend considering any relevant flow features that were not included in the FY14 model. In the absence of experimental data, it is particularly important to consider any sources of heat in the domain or boundary conditions that may affect the flow and incorporate these into the simulation if they are significant. Additionally, any geometric features of the beamline segment should be added to the model such as the orifice plate. The FY14 model works with hydrogen. An improvement that can be made for FY15 is to develop CFD properties for tritium and incorporate those properties into the new models.

  20. Real-time 3-D SAFT-UT system evaluation and validation

    International Nuclear Information System (INIS)

    Doctor, S.R.; Schuster, G.J.; Reid, L.D.; Hall, T.E.

    1996-09-01

    SAFT-UT technology is shown to provide significant enhancements to the inspection of materials used in US nuclear power plants. This report provides guidelines for the implementation of SAFT-UT technology and shows the results from its application. An overview of the development of SAFT-UT is provided so that the reader may become familiar with the technology. Then the basic fundamentals are presented with an extensive list of references. A comprehensive operating procedure, which is used in conjunction with the SAFT-UT field system developed by Pacific Northwest Laboratory (PNL), provides the recipe for both SAFT data acquisition and analysis. The specification for the hardware implementation is provided for the SAFT-UT system along with a description of the subsequent developments and improvements. One development of technical interest is the SAFT real time processor. Performance of the real-time processor is impressive and comparison is made of this dedicated parallel processor to a conventional computer and to the newer high-speed computer architectures designed for image processing. Descriptions of other improvements, including a robotic scanner, are provided. Laboratory parametric and application studies, performed by PNL and not previously reported, are discussed followed by a section on field application work in which SAFT was used during inservice inspections of operating reactors

  1. Real-time 3-D SAFT-UT system evaluation and validation

    Energy Technology Data Exchange (ETDEWEB)

    Doctor, S.R.; Schuster, G.J.; Reid, L.D.; Hall, T.E. [Pacific Northwest National Lab., Richland, WA (United States)

    1996-09-01

    SAFT-UT technology is shown to provide significant enhancements to the inspection of materials used in US nuclear power plants. This report provides guidelines for the implementation of SAFT-UT technology and shows the results from its application. An overview of the development of SAFT-UT is provided so that the reader may become familiar with the technology. Then the basic fundamentals are presented with an extensive list of references. A comprehensive operating procedure, which is used in conjunction with the SAFT-UT field system developed by Pacific Northwest Laboratory (PNL), provides the recipe for both SAFT data acquisition and analysis. The specification for the hardware implementation is provided for the SAFT-UT system along with a description of the subsequent developments and improvements. One development of technical interest is the SAFT real time processor. Performance of the real-time processor is impressive and comparison is made of this dedicated parallel processor to a conventional computer and to the newer high-speed computer architectures designed for image processing. Descriptions of other improvements, including a robotic scanner, are provided. Laboratory parametric and application studies, performed by PNL and not previously reported, are discussed followed by a section on field application work in which SAFT was used during inservice inspections of operating reactors.

  2. Role of PGL-I antibody detection in the diagnosis of pure neural leprosy

    NARCIS (Netherlands)

    Jardim, Marcia R.; Antunes, Sergio L. G.; Simons, Brian; Wildenbeest, Joanne G.; Nery, José Augusto C.; Illarramendi, Ximena; Moraes, Milton O.; Martinez, Alejandra N.; Oskam, Linda; Faber, William R.; Sarno, Euzenir N.; Sampaio, Elizabeth P.; Bührer-Sékula, Samira

    2005-01-01

    Pure neural leprosy (PNL) is difficult to diagnose because skin lesions and acid-fast bacilli (AFB) in slit smears are absent. At present, the gold standard for PNL diagnosis is the histopathological examination of a peripheral nerve biopsy. Even so, detection of bacteria is difficult and

  3. Disfruto el poder de ser feliz: experiencia en personas que viven con VIH

    Directory of Open Access Journals (Sweden)

    Guadalupe Erendira Montoya Ramirez

    2016-12-01

    Full Text Available Las personas que viven con virus de inmunodeficiencia humana (VIH pueden presentar alteraciones biopsicosociales que generan infelicidad. La gaudibilidad (capacidad para ser feliz y disfrutar, puede favorecerse al crear nuevos patrones de conducta mental con la programación neurolingüística (PNL. El propósito fue: analizar la experiencia vivida en un taller de PNL para personas que viven con VIH, a la luz del referente teórico de; Rogers. Estudio cualitativo con diseño fenomenológico, participaron 12 personas de la Asociación CONVIHVE A.C. Michoacán, en un taller de PNL conformado por ocho sesiones. Tratamiento de datos por análisis de contenido, emergieron cinco dimensiones dejando ver el poder de cambio que tienen dichas personas para disfrutar la vida, al generar emociones positivas que se anclaron al inconsciente. Conclusiones. La PNL como intervención de enfermería favorece la gaudibilidad de las personas que viven con VIH.

  4. Subcutaneous Transitional Cell Cancer After Percutaneous Nephrolithotomy: A Case Report

    Directory of Open Access Journals (Sweden)

    Lokman Ižrkilata

    2013-10-01

    Full Text Available Transitional cell carcinomas of the upper urinary tract are rare but, highly predisposing to tumoral seeding. Percutaneous lithotripsy (PNL recently has expanded the therapeutic choices for patients with kidney stones and gained popularity by urologic surgeons. Although unusual, renal collecting system tumours may be encountered during PNL. We present and discuss the clinical course of a 48 years old male patient who underwent PNL surgery for kidney stone in whom transitional cell carcinoma in the renal collecting system obscured by stone left undiagnosed. Three months later following PNL he admitted with a bulge on lumbar region. Excisional biopsy revealed carcinoma and therefore, he was directed to chemoradiotherapy and died 21 months later. Renal collecting system tumors undiagnosed during surgery may progress and demonstrate local invasion in a short period of time. Therefore, we recommend to take more caution during any percutaneous access and to exclude the possible existence of tumor.

  5. Annotated bibliography of radioactive waste management publications at Pacific Northwest Laboratory, January 1978 through July 1982

    International Nuclear Information System (INIS)

    1982-09-01

    This bibliography lists publications (831 abstracts) from the Pacific Northwest Laboratory's Department of Energy sponsored research and development programs from January 1978 through July of 1982. The abstracts are grouped in subject categories, as shown in the table of contents. Entries in the subject index also facilitate access by subject, e.g., High-Level Radioactive Wastes. Three indexes, each preceded by a brief description, are provided: personal author, subject, and report number. Cited are research reports, journal articles, books, patents, theses, and conference papers. Excluded are technical progress reports. Since 1978 the Nuclear Waste Management Quarterly Progress Report has been published under the series number PNL-3000. Beginning in 1982, this publication has been issued semiannually, under the series number PNL-4250. This bibliography is the successor to two others, BNWL-2201 (covering the years 1965-1976) and PNL-4050 (1975-1978). It is intended to provide a useful reference to literature in waste management written or compiled by PNL staff

  6. Annotated bibliography of radioactive waste management publications at Pacific Northwest Laboratory, January 1978 through July 1982. [831 abstracts

    Energy Technology Data Exchange (ETDEWEB)

    1982-09-01

    This bibliography lists publications (831 abstracts) from the Pacific Northwest Laboratory's Department of Energy sponsored research and development programs from January 1978 through July of 1982. The abstracts are grouped in subject categories, as shown in the table of contents. Entries in the subject index also facilitate access by subject, e.g., High-Level Radioactive Wastes. Three indexes, each preceded by a brief description, are provided: personal author, subject, and report number. Cited are research reports, journal articles, books, patents, theses, and conference papers. Excluded are technical progress reports. Since 1978 the Nuclear Waste Management Quarterly Progress Report has been published under the series number PNL-3000. Beginning in 1982, this publication has been issued semiannually, under the series number PNL-4250. This bibliography is the successor to two others, BNWL-2201 (covering the years 1965-1976) and PNL-4050 (1975-1978). It is intended to provide a useful reference to literature in waste management written or compiled by PNL staff.

  7. Experimental study of glass sampling devices

    International Nuclear Information System (INIS)

    Jouan, A.; Moncouyoux, J.P.; Meyere, A.

    1992-01-01

    Two high-level liquid waste containment glass sampling systems have been designed and built. The first device fits entirely inside a standard glass storage canister, and may thus be used in facilities not initially designed for this function. It has been tested successfully in the nonradioactive prototype unit at Marcoule. The work primarily covered the design and construction of an articulated arm supporting the sampling vessel, and the mechanisms necessary for filling the vessel and recovering the sample. System actuation and operation are fully automatic, and the resulting sample is representative of the glass melt. Implementation of the device is delicate however, and its reliability is estimated at about 75%. A second device was designed specifically for new vitrification facilities. It is installed directly on the glass melting furnace, and meets process operating and quality control requirements. Tests conducted at the Marcoule prototype vitrification facility demonstrated the feasibility of the system. Special attention was given to the sampling vessel transfer mechanisms, with two filling and controlled sample cooling options

  8. Use of fine needle aspirate from peripheral nerves of pure-neural leprosy for cytology and PCR to confirm the diagnosis: A pilot study

    Directory of Open Access Journals (Sweden)

    Abu Hena Hasanoor Reja

    2013-01-01

    Full Text Available Background: The diagnosis of pure neural leprosy (PNL remained subjective because of over-dependence of clinical expertise and a lack of simple yet reliable diagnostic tool. The criteria for diagnosis, proposed by Jardim et al., are not routinely done by clinicians in developing country as it involves invasive nerve biopsy and sophisticated anti-PGL-1 detection. We conducted a study using fine needle aspiration cytology (FNAC coupled with Ziehl Neelsen staining (ZN staining and Multiplex- Polymerase Chain Reaction (PCR specific for M. leprae for an objective diagnosis of pure neural leprosy (PNL, which may be simpler and yet reliable. Aim: The aim of the study is to couple FNAC with ZN staining and multiplex PCR to diagnose pure neural leprosy patients rapidly, in simpler and yet reliable way. Methods: Thirteen patients of PNL as diagnosed by two independent consultants were included as case, and 5 patients other than PNL were taken as control in the study. Fine needle aspiration was done on the affected nerve, and aspirates were evaluated for cytology, ZN staining and multiplex- PCR. Results: Out of the 13 cases where fine needle aspiration was done, M. leprae could be elicited in the nerve tissue aspirates in 5 cases (38.4% with the help of conventional acid-fast staining and 11 cases (84.6% with the help of multiplex PCR. On cytological examination of the aspirates, only 3 (23% cases showed specific epithelioid cells, whereas 8 (61.5% cases showed non-specific inflammation, and 2 (15.3% cases had no inflammatory cells. Conclusion: Our study demonstrates that in the field of laboratory diagnosis of PNL cases, FNAC in combination with ZN staining for acid-fast bacilli (AFB and Multiplex-PCR can provide a rapid and definitive diagnosis for the majority of PNL cases. FNAC is a less-invasive, outdoor-based and simpler technique than invasive nerve biopsy procedure. Thus, this study may enlighten the future path for easy and reliable diagnosis of

  9. Radiation exposure of patient and surgeon in minimally invasive kidney stone surgery.

    Science.gov (United States)

    Demirci, A; Raif Karabacak, O; Yalçınkaya, F; Yiğitbaşı, O; Aktaş, C

    2016-05-01

    Percutaneous nephrolithotomy (PNL) and retrograde intrarenal surgery (RIRS) are the standard treatments used in the endoscopic treatment of kidney stones depending on the location and the size of the stone. The purpose of the study was to show the radiation exposure difference between the minimally invasive techniques by synchronously measuring the amount of radiation the patients and the surgeon received in each session, which makes our study unique. This is a prospective study which included 20 patients who underwent PNL, and 45 patients who underwent RIRS in our clinic between June 2014 and October 2014. The surgeries were assessed by dividing them into three steps: step 1: the access sheath or ureter catheter placement, step 2: lithotripsy and collection of fragments, and step 3: DJ catheter or re-entry tube insertion. For the PNL and RIRS groups, mean stone sizes were 30mm (range 16-60), and 12mm (range 7-35); mean fluoroscopy times were 337s (range 200-679), and 37s (range 7-351); and total radiation exposures were 142mBq (44.7 to 221), and 4.4mBq (0.2 to 30) respectively. Fluoroscopy times and radiation exposures at each step were found to be higher in the PNL group compared to the RIRS group. When assessed in itself, the fluoroscopy time and radiation exposure were stable in RIRS, and the radiation exposure was the highest in step 1 and the lowest in step 3 in PNL. When assessed for the 19 PNL patients and the 12 RIRS patients who had stone sizes≥2cm, the fluoroscopy time in step 1, and the radiation exposure in steps 1 and 2 were found to be higher in the PNL group than the RIRS group (PPNL because it has short fluoroscopy time and the radiation exposure is low in every step. 4. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  10. Pacific Northwest Laboratory ALARA report for Calendar Year 1994

    International Nuclear Information System (INIS)

    Keller, S.L.

    1995-08-01

    This report provides summary results of the Calendar Year (CY) 1994 As Low As Reasonably Achievable (ALARA) Program performance at the Pacific Northwest Laboratory (PNL). This report includes data regarding performance in the area of personnel exposures to radiation, skin contaminations, control of contaminated areas, minimization of radioactive waste, and control of radioactive releases. In CY 1994: (1) The collective total effective dose equivalent to PNL employees during 1994 was 55 person-rem. The Field Dosimetry Services of the Radiological Control Department, Technical Support Section, projected that no PNL employee's dose would exceed 2 rem based on dosimeters processed during the year; no worker actually exceeded the projection-by the end of CY 1994. The maximum dose to any individual was 1.11 rem. (2) There were 34 instances of skin and personal-clothing contamination events for PNL employees during 1994. Eighteen of these contamination events occurred at the 324 Building; eleven occurred at the 325 Building; two occurred in the 327 Building; one occurred in the 326 Building; one occurred in the 3708 Building; and one occurred in the RTL Building. (3) PNL facilities contained 12 Airborne Radioactivity Areas, and 60 Contamination Areas and High Contamination Areas. The area of the Airborne Radioactivity Areas was 383 m 2 (4125 ft 2 ). The area of the Contamination Areas was 5290 m 2 (56,947 ft 2 ). The area of the High Contamination Areas was 266 m 2 (2863 ft 2 ). (4) PNL disposed of 10.5 m 3 (371 ft 3 ) of compacted low level waste. Also disposed was 423 m 3 (14,949 ft 3 ) of noncompacted low level and mixed waste that was not subject to volume reduction. The total radioactivity of the disposed waste was 1217 Ci. (5) PNL facilities released 165.2 Ci of noble gas, 3.0E-5 Ci of airborne particulate radioactive material, and 12.2 Ci of tritium to the environment

  11. The Navruz Project: Transboundary Monitoring for Radionuclides and Metals in Central Asia Rivers. Sampling and Analysis Plan and Operational Manual

    International Nuclear Information System (INIS)

    Passell, Howard D.; Barber, David S.; Betsill, J. David; Littlfield, Adriane C.; Mohagheghi, Amir H.; Shanks, Sonoya T.; Yuldashev, Bekhzad; Salikhbaev, Umar; Radyuk, Raisa; Djuraev, Akram; Djuraev, Amwar; Vasilev, Ivan; Tolongutov, Bajgabyl; Valentina, Alekhina; Solodukhin, Vladimir; Pozniak, Victor

    2002-01-01

    The transboundary nature of water resources demands a transboundary approach to their monitoring and management. However, transboundary water projects raise a challenging set of problems related to communication issues, and standardization of sampling, analysis and data management methods. This manual addresses those challenges and provides the information and guidance needed to perform the Navruz Project, a cooperative, transboundary, river monitoring project involving rivers and institutions in Kazakhstan, Kyrgyzstan, Tajikistan, and Uzbekistan facilitated by Sandia National Laboratories in the U.S. The Navruz Project focuses on waterborne radionuclides and metals because of their importance to public health and nuclear materials proliferation concerns in the region. This manual provides guidelines for participants on sample and data collection, field equipment operations and procedures, sample handling, laboratory analysis, and data management. Also included are descriptions of rivers, sampling sites and parameters on which data are collected. Data obtained in this project are shared among all participating countries and the public through an internet web site, and are available for use in further studies and in regional transboundary water resource management efforts. Overall, the project addresses three main goals: to help increase capabilities in Central Asian nations for sustainable water resources management; to provide a scientific basis for supporting nuclear transparency and non-proliferation in the region; and to help reduce the threat of conflict in Central Asia over water resources, proliferation concerns, or other factors.

  12. The Navruz Project: Transboundary Monitoring for Radionuclides and Metals in Central Asia Rivers. Sampling and Analysis Plan and Operational Manual

    Energy Technology Data Exchange (ETDEWEB)

    Passell, Howard D.; Barber, David S.; Betsill, J. David; Littlfield, Adriane C.; Mohagheghi, Amir H.; Shanks, Sonoya T.; Yuldashev, Bekhzad; Salikhbaev, Umar; Radyuk, Raisa; Djuraev, Akram; Djuraev, Amwar; Vasilev, Ivan; Tolongutov, Bajgabyl; Valentina, Alekhina; Solodukhin, Vladimir; Pozniak, Victor

    2002-04-02

    The transboundary nature of water resources demands a transboundary approach to their monitoring and management. However, transboundary water projects raise a challenging set of problems related to communication issues, and standardization of sampling, analysis and data management methods. This manual addresses those challenges and provides the information and guidance needed to perform the Navruz Project, a cooperative, transboundary, river monitoring project involving rivers and institutions in Kazakhstan, Kyrgyzstan, Tajikistan, and Uzbekistan facilitated by Sandia National Laboratories in the U.S. The Navruz Project focuses on waterborne radionuclides and metals because of their importance to public health and nuclear materials proliferation concerns in the region. This manual provides guidelines for participants on sample and data collection, field equipment operations and procedures, sample handling, laboratory analysis, and data management. Also included are descriptions of rivers, sampling sites and parameters on which data are collected. Data obtained in this project are shared among all participating countries and the public through an internet web site, and are available for use in further studies and in regional transboundary water resource management efforts. Overall, the project addresses three main goals: to help increase capabilities in Central Asian nations for sustainable water resources management; to provide a scientific basis for supporting nuclear transparency and non-proliferation in the region; and to help reduce the threat of conflict in Central Asia over water resources, proliferation concerns, or other factors.

  13. Operational reactor physics analysis codes (ORPAC)

    International Nuclear Information System (INIS)

    Kumar, Jainendra; Singh, K.P.; Singh, Kanchhi

    2007-07-01

    For efficient, smooth and safe operation of a nuclear research reactor, many reactor physics evaluations are regularly required. As part of reactor core management the important activities are maintaining core reactivity status, core power distribution, xenon estimations, safety evaluation of in-pile irradiation samples and experimental assemblies and assessment of nuclear safety in fuel handling/storage. In-pile irradiation of samples requires a prior estimation of the reactivity load due to the sample, the heating rate and the activity developed in it during irradiation. For the safety of personnel handling irradiated samples the dose rate at the surface of shielded flask housing the irradiated sample should be less than 200 mR/Hr.Therefore, a proper shielding and radioactive cooling of the irradiated sample are required to meet the said requirement. Knowledge of xenon load variation with time (Startup-curve) helps in estimating Xenon override time. Monitoring of power in individual fuel channels during reactor operation is essential to know any abnormal power distribution to avoid unsafe situations. Complexities in the estimation of above mentioned reactor parameters and their frequent requirement compel one to use computer codes to avoid possible human errors. For efficient and quick evaluation of parameters related to reactor operations such as xenon load, critical moderator height and nuclear heating and reactivity load of isotope samples/experimental assembly, a computer code ORPAC (Operational Reactor Physics Analysis Codes) has been developed. This code is being used for regular assessment of reactor physics parameters in Dhruva and Cirus. The code ORPAC written in Visual Basic 6.0 environment incorporates several important operational reactor physics aspects on a single platform with graphical user interfaces (GUI) to make it more user-friendly and presentable. (author)

  14. Wilsonville wastewater sampling program. Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1983-10-01

    As part of its contrast to design, build and operate the SRC-1 Demonstration Plant in cooperation with the US Department of Energy (DOE), International Coal Refining Company (ICRC) was required to collect and evaluate data related to wastewater streams and wastewater treatment procedures at the SRC-1 Pilot Plant facility. The pilot plant is located at Wilsonville, Alabama and is operated by Catalytic, Inc. under the direction of Southern Company Services. The plant is funded in part by the Electric Power Research Institute and the DOE. ICRC contracted with Catalytic, Inc. to conduct wastewater sampling. Tasks 1 through 5 included sampling and analysis of various wastewater sources and points of different steps in the biological treatment facility at the plant. The sampling program ran from May 1 to July 31, 1982. Also included in the sampling program was the generation and analysis of leachate from SRC product using standard laboratory leaching procedures. For Task 6, available plant wastewater data covering the period from February 1978 to December 1981 was analyzed to gain information that might be useful for a demonstration plant design basis. This report contains a tabulation of the analytical data, a summary tabulation of the historical operating data that was evaluated and comments concerning the data. The procedures used during the sampling program are also documented.

  15. Cluster lot quality assurance sampling: effect of increasing the number of clusters on classification precision and operational feasibility.

    Science.gov (United States)

    Okayasu, Hiromasa; Brown, Alexandra E; Nzioki, Michael M; Gasasira, Alex N; Takane, Marina; Mkanda, Pascal; Wassilak, Steven G F; Sutter, Roland W

    2014-11-01

    To assess the quality of supplementary immunization activities (SIAs), the Global Polio Eradication Initiative (GPEI) has used cluster lot quality assurance sampling (C-LQAS) methods since 2009. However, since the inception of C-LQAS, questions have been raised about the optimal balance between operational feasibility and precision of classification of lots to identify areas with low SIA quality that require corrective programmatic action. To determine if an increased precision in classification would result in differential programmatic decision making, we conducted a pilot evaluation in 4 local government areas (LGAs) in Nigeria with an expanded LQAS sample size of 16 clusters (instead of the standard 6 clusters) of 10 subjects each. The results showed greater heterogeneity between clusters than the assumed standard deviation of 10%, ranging from 12% to 23%. Comparing the distribution of 4-outcome classifications obtained from all possible combinations of 6-cluster subsamples to the observed classification of the 16-cluster sample, we obtained an exact match in classification in 56% to 85% of instances. We concluded that the 6-cluster C-LQAS provides acceptable classification precision for programmatic action. Considering the greater resources required to implement an expanded C-LQAS, the improvement in precision was deemed insufficient to warrant the effort. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2014. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  16. 40 CFR 61.54 - Sludge sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Sludge sampling. 61.54 Section 61.54... sampling. (a) As an alternative means for demonstrating compliance with § 61.52(b), an owner or operator... days prior to a sludge sampling test, so that he may at his option observe the test. (c) Sludge shall...

  17. Surface radiation survey and soil sampling of the 300-FF-1 operable unit, Hanford Site, southeastern Washington: A case study

    International Nuclear Information System (INIS)

    Teel, S.S.; Olsen, K.B.

    1990-10-01

    The methods used for conducting a radiological characterization of the soil surface for the Phase I Remedial Investigation of a Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) site is presented via a case study. The study site is an operable unit (300-FF-1) located in and adjacent to the 300 Area of the US Department of Energy's Hanford Site in southeastern Washington State. The operable unit contains liquid and solid waste disposal facilities associated with nuclear fuels fabrication. Continuous surface radiation surveying and soil sampling of selected locations were conducted. Contamination was found in several locations within the operable unit including areas near the liquid and solid waste disposal facilities. Instruments used during surveying included portable beta/gamma (P-11) detectors, and the Ultrasonic Ranging and Data System using an NaI (Tl) detector. Laboratory analyses results indicate that above-background radiation levels were primarily due to the presence of uranium. Both types of field instruments used in the study were effective in detecting surface contamination from radionuclides; however, each had specific advantages. Guidelines are presented for the optimum use of these instruments when performing a radiological characterization of the soil surface. 4 refs., 3 figs., 3 tabs

  18. Estimating Bodywave Arrivals and Attenuation from Seismic Noise

    Science.gov (United States)

    2009-09-30

    power) and Figure 3d the standardized site amplification terms from Savage and Helmberger (2004) who used the Pnl ratio of vertical to radial energy...incident Pnl waves, Bull. Seismol. Soc. Am. 94: 357-362. Shearer, P. (1997). Improving local earthquake locations using the LI norm and waveform

  19. A model of positive and negative learning : Learning demands and resources, learning engagement, critical thinking, and fake news detection

    NARCIS (Netherlands)

    Dormann, Christian; Demerouti, Eva; Bakker, Arnold; Zlatkin-Troitschanskaia, O.; Wittum, G.; Dengel, A.

    2018-01-01

    This chapter proposes a model of positive and negative learning (PNL model). We use the term negative learning when stress among students occurs, and when knowledge and abilities are not properly developed. We use the term positive learning if motivation is high and active learning occurs. The PNL

  20. Hanford cultural resources laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Wright, M.K.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report describes activities of the Hanford Cultural Resources Laboratory (HCRL) which was established by the Richland Operations Office in 1987 as part of PNL.The HCRL provides support for the management of the archaeological, historical, and traditional cultural resources of the site in a manner consistent with the National Historic Preservation Act, the Native American Graves Protection and Repatriation Act, and the American Indian Religious Freedom Act.

  1. Hanford cultural resources laboratory

    International Nuclear Information System (INIS)

    Wright, M.K.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report describes activities of the Hanford Cultural Resources Laboratory (HCRL) which was established by the Richland Operations Office in 1987 as part of PNL.The HCRL provides support for the management of the archaeological, historical, and traditional cultural resources of the site in a manner consistent with the National Historic Preservation Act, the Native American Graves Protection and Repatriation Act, and the American Indian Religious Freedom Act

  2. Automatic remote sampling and delivery system incorporating decontamination and disposal of sample bottles

    International Nuclear Information System (INIS)

    Savarkar, V.K.; Mishra, A.K.; Bajpai, D.D.; Nair, M.K.T.

    1990-01-01

    The present generation of reprocessing plants have sampling and delivery systems that have to be operated manually with its associated problems. The complete automation and remotisation of sampling system has hence been considered to reduce manual intervention and personnel exposure. As a part of this scheme an attempt to automate and remotise various steps in sampling system has been made. This paper discusses in detail the development work carried out in this area as well as the tests conducted to incorporate the same in the existing plants. (author). 3 figs

  3. Low-sampling-rate ultra-wideband digital receiver using equivalent-time sampling

    KAUST Repository

    Ballal, Tarig

    2014-09-01

    In this paper, we propose an all-digital scheme for ultra-wideband symbol detection. In the proposed scheme, the received symbols are sampled many times below the Nyquist rate. It is shown that when the number of symbol repetitions, P, is co-prime with the symbol duration given in Nyquist samples, the receiver can sample the received data P times below the Nyquist rate, without loss of fidelity. The proposed scheme is applied to perform channel estimation and binary pulse position modulation (BPPM) detection. Results are presented for two receivers operating at two different sampling rates that are 10 and 20 times below the Nyquist rate. The feasibility of the proposed scheme is demonstrated in different scenarios, with reasonable bit error rates obtained in most of the cases.

  4. Low-sampling-rate ultra-wideband digital receiver using equivalent-time sampling

    KAUST Repository

    Ballal, Tarig; Al-Naffouri, Tareq Y.

    2014-01-01

    In this paper, we propose an all-digital scheme for ultra-wideband symbol detection. In the proposed scheme, the received symbols are sampled many times below the Nyquist rate. It is shown that when the number of symbol repetitions, P, is co-prime with the symbol duration given in Nyquist samples, the receiver can sample the received data P times below the Nyquist rate, without loss of fidelity. The proposed scheme is applied to perform channel estimation and binary pulse position modulation (BPPM) detection. Results are presented for two receivers operating at two different sampling rates that are 10 and 20 times below the Nyquist rate. The feasibility of the proposed scheme is demonstrated in different scenarios, with reasonable bit error rates obtained in most of the cases.

  5. Programmable automatic alpha--beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.

    1978-01-01

    A programmable automatic alpha-beta air sample counter was developed for routine sample counting by operational health physics personnel. The system is composed of an automatic sample changer utilizing a large silicon diode detector, an electronic counting system with energy analysis capability, an automatic data acquisition controller, an interface module, and a teletypewriter with paper tape punch and paper tape reader. The system is operated through the teletypewriter keyboard and the paper tape reader, which are used to instruct the automatic data acquisition controller. Paper tape programs are provided for background counting, Chi 2 test, and sample counting. Output data are printed by the teletypewriter on standard continuous roll or multifold paper. Data are automatically corrected for background and counter efficiency

  6. The new Chalk River AMS ion source, sample changer and external sample magazine

    International Nuclear Information System (INIS)

    Koslowsky, V.T.; Bray, N.; Imahori, Y.; Andrews, H.R.; Davies, W.G.

    1997-01-01

    A new sample magazine, sample changer and ion source have been developed and are in routine use at Chalk River. The system features a readily accessible 40-sample magazine at ground potential that is external to the ion source and high-voltage cage. The samples are held in an inert atmosphere and can be individually examined or removed; they can be exchanged en masse as a complete magazine concurrent with an AMS measurement. On-line sample changing is done with a pneumatic rabbit transfer system employing two stages of differential pumping. At Chalk River this is routinely performed across a 200 kV potential. Sample positioning is precise, and hundreds of 36 Cl and 129 I samples have been measured over a period of several days without interruption or alteration of ion source operating conditions. (author)

  7. Solvent Hold Tank Sample Results for MCU-16-934-935-936: June 2016 Monthly Sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-08-30

    Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-934-935-936), pulled on 07/01/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-934-935-936 indicated the Isopar™L concentration is above its nominal level (101%). The modifier (CS-7SB) and the TiDG concentrations are 8% and 29 % below their nominal concentrations. This analysis confirms the solvent may require the addition of TiDG, and possibly of modifier. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). However, up to 21.1 ± 4 micrograms of mercury per gram of solvent (or 17.5 μg/mL) was detected in this sample (as determined by the XRF method of undigested sample). The current gamma level (1.41E5 dpm/mL) confirmed that the gamma concentration has returned to previous levels (as observed in the late 2015 samples) where the process operated normally and as expected.

  8. Receiver operating characteristics of perceptrons : Influence of sample size and prevalence

    NARCIS (Netherlands)

    Freking, Ansgar; Biehl, Michael; Braun, Christian; Kinzel, Wolfgang; Meesmann, Malte

    1999-01-01

    In many practical classification problems it is important to distinguish false positive from false negative results when evaluating the performance of the classifier. This is of particular importance for medical diagnostic tests. In this context, receiver operating characteristic (ROC) curves have

  9. Fluidic sampling

    International Nuclear Information System (INIS)

    Houck, E.D.

    1992-01-01

    This paper covers the development of the fluidic sampler and its testing in a fluidic transfer system. The major findings of this paper are as follows. Fluidic jet samples can dependably produce unbiased samples of acceptable volume. The fluidic transfer system with a fluidic sampler in-line will transfer water to a net lift of 37.2--39.9 feet at an average ratio of 0.02--0.05 gpm (77--192 cc/min). The fluidic sample system circulation rate compares very favorably with the normal 0.016--0.026 gpm (60--100 cc/min) circulation rate that is commonly produced for this lift and solution with the jet-assisted airlift sample system that is normally used at ICPP. The volume of the sample taken with a fluidic sampler is dependant on the motive pressure to the fluidic sampler, the sample bottle size and on the fluidic sampler jet characteristics. The fluidic sampler should be supplied with fluid having the motive pressure of the 140--150 percent of the peak vacuum producing motive pressure for the jet in the sampler. Fluidic transfer systems should be operated by emptying a full pumping chamber to nearly empty or empty during the pumping cycle, this maximizes the solution transfer rate

  10. Base Realignment and Closure: An Evolution for Harvesting Efficiencies

    Science.gov (United States)

    2012-06-15

    JIOI .1 I’\\ ( a~~:c ...... cu t\\ pnl 17. 20 1::!!. 16 The Commiss ion’s review of the military force strucrure and basing requi rements wa~ geared...II I II,JII __ (lt_ ( )iloltll~_ ( <o• l t.\\tl __ [,q tllt<’ll\\ (’dl !<t~<.: C’-’- t.: d t\\ pnl :!(l. 21!1 :2). ’i U.S. Ctt~,·rnutt: lll At... pnl 2.\\. 2012 ). I ’ . - ll11ll. 6 1 Durin~ the BRJ\\C 2005 i nau~ural hcmi nu in IVlav nf 2005. G;\\0 ’"’"" a"ked w addre:-.s: .... .._ ..... - ( I

  11. Intraperitoneal stone migration during percutaneos nephrolithotomy

    Directory of Open Access Journals (Sweden)

    Akif Diri

    2014-12-01

    Full Text Available Percutaneos nephrolithotomy (PNL is the standard care for renal stones larger than 2 cm. The procedure has some major and minor complications. Renal pelvis laceration and stone migration to the retroperitoneum is one of the rare condition. We report the first case of intraperitoneal stone migration during PNL.

  12. Prototype firing range air cleaning system

    International Nuclear Information System (INIS)

    Glissmeyer, J.A.; Mishima, J.; Bamberger, J.A.

    1984-07-01

    PNL's study proceeded by examining the characteristics of the aerosol challenge to the filtration system and the operating experience at similar firing ranges. Candidate filtration systems were proposed; including baghouses, cartridge houses, electrostatic precipitators, cleanable high efficiency filters, rolling filters and cyclones--each followed by one or more of the existing filter banks. Methodology was developed to estimate the operating costs of the candidate systems. Costs addressed included the frequency (based on fractional efficiency and loading data) and cost of media replacement, capital investment, maintenance, waste disposal and electrical power consumption. The recommended system will be installed during calendar year 1984

  13. Hanford Site background: Evaluation of existing soil radionuclide data

    International Nuclear Information System (INIS)

    1995-07-01

    This report is an evaluation of the existing data on radiological background for soils in the vicinity of the Hanford Site. The primary purpose of this report is to assess the adequacy of the existing data to serve as a radiological background baseline for use in environmental restoration and remediation activities at the Hanford Site. The soil background data compiled and evaluated in this report were collected by the Pacific Northwest Laboratory (PNL) and Washington State Department of Health (DOH) radiation surveillance programs in southeastern Washington. These two programs provide the largest well-documented, quantitative data sets available to evaluate background conditions at the Hanford Site. The data quality objectives (DQOs) considered in this evaluation include the amount of data, number of sampling localities, spatial coverage, number and types of radionuclides reported, frequency of reporting, documentation and traceability of sampling and laboratory methods used, and comparability between sets of data. Although other data on soil radionuclide abundances around the Hanford Site exist, they are generally limited in scope and lack the DQOs necessary for consideration with the PNL and DOH data sets. Collectively, these two sources provide data on the activities of 25 radionuclides and four other parameters (gross alpha, gross beta, total uranium, and total thorium). These measurements were made on samples from the upper 2.5 cm of soil at over 70 localities within the region

  14. Thermal and Evolved Gas Analysis of Calcite Under Reduced Operating Pressures: Implications for the 2011 MSL Sample Analysis at Mars (SAM) Instrument

    Science.gov (United States)

    Lauer, H. V. Jr.; Ming, D. W.; Sutter, B.; Mahaffy, P. R.

    2010-01-01

    The Mars Science Laboratory (MSL) is scheduled for launch in 2011. The science objectives for MSL are to assess the past or present biological potential, to characterize the geology, and to investigate other planetary processes that influence habitability at the landing site. The Sample Analysis at Mars (SAM) is a key instrument on the MSL payload that will explore the potential habitability at the landing site [1]. In addition to searching for organic compounds, SAM will have the capability to characterized evolved gases as a function of increasing temperature and provide information on the mineralogy of volatile-bearing phases such as carbonates, sulfates, phyllosilicates, and Fe-oxyhydroxides. The operating conditions in SAM ovens will be maintained at 30 mb pressure with a He carrier gas flowing at 1 sccm. We have previously characterized the thermal and evolved gas behaviors of volatile-bearing species under reduced pressure conditions that simulated operating conditions of the Thermal and Evolved Gas Analyzer (TEGA) that was onboard the 2007 Mars Phoenix Scout Mission [e.g., 2-8]. TEGA ovens operated at 12 mb pressure with a N2 carrier gas flowing at 0.04 sccm. Another key difference between SAM and TEGA is that TEGA was able to perform differential scanning calorimetry whereas SAM only has a pyrolysis oven. The operating conditions for TEGA and SAM have several key parameter differences including operating pressure (12 vs 30 mb), carrier gas (N2 vs. He), and carrier gas flow rate (0.04 vs 1 sccm). The objectives of this study are to characterize the thermal and evolved gas analysis of calcite under SAM operating conditions and then compare it to calcite thermal and evolved gas analysis under TEGA operating conditions.

  15. Structure of Hilbert space operators

    CERN Document Server

    Jiang, Chunlan

    2006-01-01

    This book exposes the internal structure of non-self-adjoint operators acting on complex separable infinite dimensional Hilbert space, by analyzing and studying the commutant of operators. A unique presentation of the theorem of Cowen-Douglas operators is given. The authors take the strongly irreducible operator as a basic model, and find complete similarity invariants of Cowen-Douglas operators by using K -theory, complex geometry and operator algebra tools. Sample Chapter(s). Chapter 1: Background (153 KB). Contents: Jordan Standard Theorem and K 0 -Group; Approximate Jordan Theorem of Opera

  16. OPERATION OF A PUBLIC GEOLOGIC CORE AND SAMPLE REPOSITORY IN HOUSTON TEXAS

    Energy Technology Data Exchange (ETDEWEB)

    Scott W. Tinker

    2003-06-01

    In the spring of 2002, the Department of Energy provided an initial 1-year grant to the Bureau of Economic Geology (BEG) at The University of Texas at Austin (UT). The grant covered the one-year operational expenses of a worldclass core and cuttings facility located in Houston, Texas, that BP America donated to the BEG. The DOE investment of $300,000, matched by a $75,000 UT contribution, provided critical first-year funds that were heavily leveraged by the BP gift of $7.0 million in facilities and cash. DOE also provided a one-month extension and grant of $30,000 for the month of May 2003. A 5-year plan to grow a permanent endowment in order to manage the facility in perpetuity is well under way and on schedule. The facility, named the Houston Research Center, represents an ideal model for a strong Federal, university, and private partnership to accomplish a national good. This report summarizes the activities supported by the initial DOE grant during the first 13 months of operation and provides insight into the activities and needs of the facility in the second year of operation.

  17. The Department of Defense Global, Laboratory-Based Influenza Surveillance Program: Technical Report on Program Methods for the 2012-2013 Influenza Season

    Science.gov (United States)

    2013-10-01

    PNL (EPI)” in AHLTA/CHCS, where available To request col lection kits, use the current ve rsion of the “Supply Orde r Form ” avai lable (under...Influenza Surveillance Program Sentinel Sites • Order the “RESPIRATORY CULTURE PNL (EPI)” in AHLTA/CHCS, where available • Submit 6-10 specimens

  18. Stochastic Pseudo-Boolean Optimization

    Science.gov (United States)

    2011-07-31

    16 polyominoes. Given this notation, we provide the following nonlinear mixed integer programming (MIP) formulation of the exact tiling problem: PNL ...ri, cj ≥ 0 ∀ i, j, p, q, k. 8.3.3 Linear Set Partitioning Formulation We use value disjunctions to reformulate PNL as a linear MIP that can be

  19. Characterization of Volatiles Loss from Soil Samples at Lunar Environments

    Science.gov (United States)

    Kleinhenz, Julie; Smith, Jim; Roush, Ted; Colaprete, Anthony; Zacny, Kris; Paulsen, Gale; Wang, Alex; Paz, Aaron

    2017-01-01

    Resource Prospector Integrated Thermal Vacuum Test Program A series of ground based dirty thermal vacuum tests are being conducted to better understand the subsurface sampling operations for RP Volatiles loss during sampling operations Hardware performance Sample removal and transfer Concept of operationsInstrumentation5 test campaigns over 5 years have been conducted with RP hardware with advancing hardware designs and additional RP subsystems Volatiles sampling 4 years Using flight-forward regolith sampling hardware, empirically determine volatile retention at lunar-relevant conditions Use data to improve theoretical predictions Determine driving variables for retention Bound water loss potential to define measurement uncertainties. The main goal of this talk is to introduce you to our approach to characterizing volatiles loss for RP. Introduce the facility and its capabilities Overview of the RP hardware used in integrated testing (most recent iteration) Summarize the test variables used thus farReview a sample of the results.

  20. 30 CFR 70.201 - Sampling; general requirements.

    Science.gov (United States)

    2010-07-01

    ...; general requirements. (a) Each operator shall take respirable dust samples of the concentration of respirable dust in the active workings of the mine as required by this part with a sampling device approved... Personal Sampler Units) of this title. (b) Sampling devices shall be worn or carried directly to and from...

  1. Development of sampling techniques for ITER Type B radwaste

    International Nuclear Information System (INIS)

    Hong, Kwon Pyo; Kim, Sung Geun; Jung, Sang Hee; Oh, Wan Ho; Park, Myung Chul; Kim, Hee Moon; Ahn, Sang Bok

    2016-01-01

    There are several difficulties and limitation in sampling activities. As the Type B radwaste components are mostly metallic(mostly stainless steel) and bulk(∼ 1 m in size and ∼ 100 mm in thickness), it is difficult in taking samples from the surface of Type B radwaste by remote operation. But also, sampling should be performed without use of any liquid coolant to avoid the spread of contamination. And all sampling procedures are carried in the hot cell red zone with remote operation. Three kinds of sampling techniques are being developed. They are core sampling, chip sampling, and wedge sampling, which are the candidates of sampling techniques to be applied to ITER hot cell. Object materials for sampling are stainless steel or Cu alloy block in order to simulate ITER Type B radwaste. The best sampling technique for ITER Type B radwaste among the three sampling techniques will be suggested in several months after finishing the related experiment

  2. Development of sampling techniques for ITER Type B radwaste

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Kwon Pyo; Kim, Sung Geun; Jung, Sang Hee; Oh, Wan Ho; Park, Myung Chul; Kim, Hee Moon; Ahn, Sang Bok [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    There are several difficulties and limitation in sampling activities. As the Type B radwaste components are mostly metallic(mostly stainless steel) and bulk(∼ 1 m in size and ∼ 100 mm in thickness), it is difficult in taking samples from the surface of Type B radwaste by remote operation. But also, sampling should be performed without use of any liquid coolant to avoid the spread of contamination. And all sampling procedures are carried in the hot cell red zone with remote operation. Three kinds of sampling techniques are being developed. They are core sampling, chip sampling, and wedge sampling, which are the candidates of sampling techniques to be applied to ITER hot cell. Object materials for sampling are stainless steel or Cu alloy block in order to simulate ITER Type B radwaste. The best sampling technique for ITER Type B radwaste among the three sampling techniques will be suggested in several months after finishing the related experiment.

  3. Cape Canaveral Air Force Station integrated resource assessment. Volume 3, Resource assessment

    Energy Technology Data Exchange (ETDEWEB)

    Sandusky, W.F.; Eichman, C.J.; King, D.A.; McMordie, K.L.; Parker, S.A.; Shankle, S.A.; Wahlstrom, R.R.

    1994-03-01

    The U.S. Air Force (USAF) has tasked the Pacific Northwest Laboratory (PNL) in support of the U.S. Department of Energy (DOE) Federal Energy Management Program (FEMP), to identify, evaluate, and assist in acquiring all cost-effective energy projects at Cape Canaveral Air Force Station (AFS). Projects considered can be either in the form of energy management or energy conservation. The overall efforts of this task are based on a model program PNL is designing to support energy-use decisions in the federal sector. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at Cape Canaveral AFS, which is located approximately 10 miles north of Cocoa Beach, Florida. It is a companion report to Volume 1: Executive Summary and Volume 2: Baseline Detail. The results of the analyses of EROs are presented in 11 common energy end-use categories (e.g., boilers and furnaces, service hot water, and building lighting). A narrative description of each ERO is provided, including information on the installed cost, energy and dollar savings, impacts on operations and maintenance (O&M), and, when applicable, a discussion of energy supply and demand, energy security, and environmental issues. Descriptions of the evaluation methodologies and technical and cost assumptions are also provided for each ERO. Summary tables present the cost- effectiveness of energy end-use equipment before and after the implementation of each ERO and present the results of the life-cycle cost (LCC) analysis, indicating the net present value (NPV) and savings-to-investment ratio (SIR) of each ERO.

  4. Radiological risk guidelines for nonreactor nuclear facilities at the Pacific Northwest Laboratory

    International Nuclear Information System (INIS)

    Lucas, D.E.; Ikenberry, T.A.

    1993-09-01

    Radiological risk evaluation guidelines for the public and workers have been developed at the Pacific Northwest Laboratory (PNL) based upon the Nuclear Safety Policy of the US Department of Energy (DOE) established in Secretary of Energy Notice SEN-35-91. The DOE nuclear safety policy states that the general public shall be protected such that no individual bears significant additional risk to health and safety from the operation of a DOE nuclear facility above the risks to which members of the general population are normally exposed. The radiological risk evaluation guidelines developed at PNL are unique in that they are (1) based upon quantitative risk goals and (2) provide a consistent level of risk management. These guidelines are used to evaluate the risk from radiological accidents that may occur during research and development activities at PNL, and are not intended for evaluation of routine exposures. A safety analyst uses the,frequency of the potential accident and the radiological dose to a given receptor to determine if the accident consequences meet the objectives of the Nuclear Safety Policy. The radiological risk evaluation guidelines are an effective tool for assisting in the management of risk at DOE nonreactor nuclear facilities. These guidelines (1) meet the nuclear safety policy of DOE, (2) establish a tool for managing risk at a consistent level within the defined constraints, and (3) set risk at an appropriate level, as compared with other risks encountered by the public and worker. Table S.1 summarizes the guidelines developed in this report

  5. Characterization of substances in products, effluents, and wastes from coal conversion processes

    International Nuclear Information System (INIS)

    Petersen, M.R.

    1978-01-01

    Researchers at Pacific Northwest Laboratory (PNL) are investigating materials from synthetic fossil fuel processes. During the past year, samples have been collected from the Solvent Refining Coal Pilot Plant (SRC-I mode), Lignite Gasification Pilot Plant, Eyring Research Institute Gasifier, and Hanna III In Situ Coal Gasification Experiment. Inorganic and organic analyses have been performed, and comparisons of the data show some important differences in the potential emissions

  6. 7 CFR 43.105 - Operating characteristics (OC) curves.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Operating characteristics (OC) curves. 43.105 Section 43.105 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE... CONTAINER REGULATIONS STANDARDS FOR SAMPLING PLANS Sampling Plans § 43.105 Operating characteristics (OC...

  7. Sample vial inserts: A better approach for sampling heterogeneous slurry samples in the SRS Defense Waste Processing Facility

    International Nuclear Information System (INIS)

    Coleman, C.J.; Goode, S.R.

    1996-01-01

    A convenient and effective new approach for analyzing DWPF samples involves the use of inserts with volumes of 1.5--3 ml placed in the neck of 14 ml sample vials. The inserts have rims that conform to the rim of the vials so that they sit straight and stable in the vial. The DWPF tank sampling system fills the pre-weighed insert rather than the entire vial, so the vial functions only as the insert holder. The shielded cell operator then removes the vial cap and decants the insert containing the sample into a plastic bottle, crucible, etc., for analysis. Inert materials such as Teflon, plastic, and zirconium are used for the insert so it is unnecessary to separate the insert from the sample for most analyses. The key technique advantage of using inserts to take DWPF samples versus filling sample vials is that it provides a convenient and almost foolproof way of obtaining and handling small volumes of slurry samples in a shielded cell without corrupting the sample. Since the insert allows the entire sample to be analyzed, this approach eliminates the errors inherent with subsampling heterogeneous slurries that comprise DWPF samples. Slurry samples can then be analyzed with confidence. Analysis times are dramatically reduced by eliminating the drying and vitrification steps normally used to produce a homogeneous solid sample. Direct dissolution and elemental analysis of slurry samples are achieved in 8 hours or less compared with 40 hours for analysis of vitrified slurry samples. Comparison of samples taken in inserts versus full vials indicate that the insert does not significantly affect sample composition

  8. Development of chemical profiles for U.S. Department of Energy low-level mixed wastes

    International Nuclear Information System (INIS)

    Wang, Y.Y.; Wilkins, B.D.; Meshkov, N.K.; Dolak, D.A.

    1995-01-01

    Chemical and radiological profiles of waste streams from US Department of Energy (DOE) low-level mixed wastes (LLMWs) have been developed by Argonne National Laboratory (ANL) to provide technical support information for evaluating waste management alternatives in the Office of Environmental Management Programmatic Environmental Impact Statement (EM PEIS). The chemical profiles were developed for LLMW generated from both Waste Management (WM) operations and from Environmental Restoration (ER) activities at DOE facilities. Information summarized in the 1994 DOE Mixed Waste Inventory Report (MWIR-2), the Pacific Northwest Laboratory (PNL) Automated Remedial Assessment Methodology (ARAM), and associated PNL supporting data on ER secondary waste streams that will be treated in WM treatment facilities were used as the sources for developing chemical profiles. The methodology for developing the LLMW chemical profiles is discussed, and the chemical profiles developed from data for contact-handled (CH) non-alpha LLMW are presented in this paper. The hazardous chemical composition of remote-handled (RH) LLMW and alpha LLMW follow the chemical profiles developed for CH non-alpha LLMW

  9. Recommendations for the treatment of aging in standard technical specifications

    International Nuclear Information System (INIS)

    Orton, R.D.; Allen, R.P.

    1995-09-01

    As part of the US Nuclear Regulatory Commission's Nuclear Plant Aging Research Program, Pacific Northwest Laboratory (PNL) evaluated the standard technical specifications for nuclear power plants to determine whether the current surveillance requirements (SRs) were effective in detecting age-related degradation. Nuclear Plant Aging Research findings for selected systems and components were reviewed to identify the stressors and operative aging mechanisms and to evaluate the methods available to detect, differentiate, and trend the resulting aging degradation. Current surveillance and testing requirements for these systems and components were reviewed for their effectiveness in detecting degraded conditions and for potential contributions to premature degradation. When the current surveillance and testing requirements appeared ineffective in detecting aging degradation or potentially could contribute to premature degradation, a possible deficiency in the SRs was identified that could result in undetected degradation. Based on this evaluation, PNL developed recommendations for inspection, surveillance, trending, and condition monitoring methods to be incorporated in the SRs to better detect age- related degradation of these selected systems and components

  10. Electric energy supply systems: description of available technologies

    Energy Technology Data Exchange (ETDEWEB)

    Eisenhauer, J.L.; Rogers, E.A.; King, J.C.; Stegen, G.E.; Dowis, W.J.

    1985-02-01

    When comparing coal transportation with electric transmission as a means of delivering electric power, it is desirable to compare entire energy systems rather than just the transportation/transmission components because the requirements of each option may affect the requirements of other energy system components. PNL's assessment consists of two parts. The first part, which is the subject of this document, is a detailed description of the technical, cost, resource and environmental characteristics of each system component and technologies available for these components. The second part is a computer-based model that PNL has developed to simulate construction and operation of alternative system configurations and to compare the performance of these systems under a variety of economic and technical conditions. This document consists of six chapters and two appendices. A more thorough description of coal-based electric energy systems is presented in the Introduction and Chapter 1. Each of the subsequent chapters describes technologies for five system components: Western coal resources (Chapter 2), coal transportation (Chapter 3), coal gasification and gas transmission (Chapter 4), and electric power transmission (Chapter 6).

  11. Sampling, storage and sample preparation procedures for X ray fluorescence analysis of environmental materials

    International Nuclear Information System (INIS)

    1997-06-01

    X ray fluorescence (XRF) method is one of the most commonly used nuclear analytical technique because of its multielement and non-destructive character, speed, economy and ease of operation. From the point of view of quality assurance practices, sampling and sample preparation procedures are the most crucial steps in all analytical techniques, (including X ray fluorescence) applied for the analysis of heterogeneous materials. This technical document covers recent modes of the X ray fluorescence method and recent developments in sample preparation techniques for the analysis of environmental materials. Refs, figs, tabs

  12. 40 CFR 61.33 - Stack sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Stack sampling. 61.33 Section 61.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... sampling. (a) Unless a waiver of emission testing is obtained under § 61.13, each owner or operator...

  13. Mammography image quality and evidence based practice: Analysis of the demonstration of the inframammary angle in the digital setting.

    Science.gov (United States)

    Spuur, Kelly; Webb, Jodi; Poulos, Ann; Nielsen, Sharon; Robinson, Wayne

    2018-03-01

    The aim of this study is to determine the clinical rates of the demonstration of the inframammary angle (IMA) on the mediolateral oblique (MLO) view of the breast on digital mammograms and to compare the outcomes with current accreditation standards for compliance. Relationships between the IMA, age, the posterior nipple line (PNL) and compressed breast thickness will be identified and the study outcomes validated using appropriate analyses of inter-reader and inter-rater reliability and variability. Differences in left versus right data were also investigated. A quantitative retrospective study of 2270 randomly selected paired digital mammograms performed by BreastScreen NSW was undertaken. Data was collected by direct measurement and visual analysis. Intra-class correlation analyses were used to evaluate inter- and intra-rater reliability. The IMA was demonstrated on 52.4% of individual and 42.6% of paired mammograms. A linear relationship was found between the posterior nipple line (PNL) and age (p-value PNL was predicted to increase by 0.48 mm for every one year increment in age. The odds of demonstrating the IMA reduced by 2% for every one year increase in age (p-value = 0.001); are 0.4% higher for every 1 mm increase in PNL (p-value = 0.001) and 1.6% lower for every 1 mm increase in compressed breast thickness, (p-valuePNL while there was 100% agreement for the demonstration of the IMA. Analysis of the demonstration of the IMA indicates clinically achievable rates (42.6%) well below that required for compliance (50%-75%) to known worldwide accreditation standards for screening mammography. These standards should be aligned to the reported evidence base. Visualisation of the IMA is impacted negatively by increasing age and compressed breast thickness but positively by breast size (PNL). Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Subject bibliography of radioactive waste management publications at Pacific Northwest Laboratory, 1975-1978

    International Nuclear Information System (INIS)

    Powell, J.A.

    1981-10-01

    This bibliography contains publications from 1975 to 1978 written by PNL staff. PNL translations are also announced in this document. The following areas are covered: actinides; airborne wastes; alternative waste forms; calcination; characterization; containers; decontamination; disposal; high-level wastes; liquid wastes; radionuclide migration; safety; separation processes; soils; solidification; storage; transport; transuranic waste; and vitrification

  15. Evaluation of Millstone Nuclear Power Plant, Environmental Impact prediction, based on monitoring programs

    International Nuclear Information System (INIS)

    Gore, K.L.; Thomas, J.M.; Kannberg, L.D.; Watson, D.G.

    1977-02-01

    This report evaluates the nonradiological monitoring program at Millstone Nuclear Power Plant. Both operational as well as preoperational monitoring programs were analyzed to produce long-term (5 yr or longer) data sets, where possible. In order to determine the effectiveness of these monitoring programs, the appropriate data sets have to be analyzed by the appropriate statistical analysis. Thus, both open literature and current statistical analysis being developed at Pacific Northwest Laboratories (PNL) were employed in data analysis

  16. Evaluation of Millstone Nuclear Power Plant, Environmental Impact prediction, based on monitoring programs

    Energy Technology Data Exchange (ETDEWEB)

    Gore, K.L.; Thomas, J.M.; Kannberg, L.D.; Watson, D.G.

    1977-02-01

    This report evaluates the nonradiological monitoring program at Millstone Nuclear Power Plant. Both operational as well as preoperational monitoring programs were analyzed to produce long-term (5 yr or longer) data sets, where possible. In order to determine the effectiveness of these monitoring programs, the appropriate data sets have to be analyzed by the appropriate statistical analysis. Thus, both open literature and current statistical analysis being developed at Pacific Northwest Laboratories (PNL) were employed in data analysis.

  17. Pacific Northwest Laboratory annual report for 1991 to the DOE Office of Energy Research. Part 2, Environmental sciences

    Energy Technology Data Exchange (ETDEWEB)

    Perez, D.A. [ed.

    1992-02-01

    This report summarizes progress in environmental sciences research conducted by Pacific Northwest Laboratory (PNL) for the US Department of Energy`s (DOE) Office of Health and Environmental Research in FY 1991. Each project in the PNL research program is a component in an integrated laboratory, intermediate-scale, and field approach designed to examine multiple phenomena at increasing levels of complexity. Examples include definition of the role of fundamental geochemical and physical phenomena on the diversity and function of microorganisms in the deep subsurface, and determination of the controls on nutrient, water, and energy dynamics in arid ecosystems and their response to stress at the landscape scale. The Environmental Science Research Center has enable PNL to extend fundamental knowledge of subsurface science to develop emerging new concepts for use in natural systems and in environmental restoration of DOE sites. New PNL investments have been made in developing advanced concepts for addressing chemical desorption kinetics, enzyme transformations and redesign, the role of heterogeneity in contaminant transport, and modeling of fundamental ecological processes.

  18. Pacific Northwest Laboratory annual report for 1991 to the DOE Office of Energy Research

    Energy Technology Data Exchange (ETDEWEB)

    Perez, D.A. (ed.)

    1992-02-01

    This report summarizes progress in environmental sciences research conducted by Pacific Northwest Laboratory (PNL) for the US Department of Energy's (DOE) Office of Health and Environmental Research in FY 1991. Each project in the PNL research program is a component in an integrated laboratory, intermediate-scale, and field approach designed to examine multiple phenomena at increasing levels of complexity. Examples include definition of the role of fundamental geochemical and physical phenomena on the diversity and function of microorganisms in the deep subsurface, and determination of the controls on nutrient, water, and energy dynamics in arid ecosystems and their response to stress at the landscape scale. The Environmental Science Research Center has enable PNL to extend fundamental knowledge of subsurface science to develop emerging new concepts for use in natural systems and in environmental restoration of DOE sites. New PNL investments have been made in developing advanced concepts for addressing chemical desorption kinetics, enzyme transformations and redesign, the role of heterogeneity in contaminant transport, and modeling of fundamental ecological processes.

  19. Pacific Northwest Laboratory annual report for 1991 to the DOE Office of Energy Research

    International Nuclear Information System (INIS)

    Perez, D.A.

    1992-02-01

    This report summarizes progress in environmental sciences research conducted by Pacific Northwest Laboratory (PNL) for the US Department of Energy's (DOE) Office of Health and Environmental Research in FY 1991. Each project in the PNL research program is a component in an integrated laboratory, intermediate-scale, and field approach designed to examine multiple phenomena at increasing levels of complexity. Examples include definition of the role of fundamental geochemical and physical phenomena on the diversity and function of microorganisms in the deep subsurface, and determination of the controls on nutrient, water, and energy dynamics in arid ecosystems and their response to stress at the landscape scale. The Environmental Science Research Center has enable PNL to extend fundamental knowledge of subsurface science to develop emerging new concepts for use in natural systems and in environmental restoration of DOE sites. New PNL investments have been made in developing advanced concepts for addressing chemical desorption kinetics, enzyme transformations and redesign, the role of heterogeneity in contaminant transport, and modeling of fundamental ecological processes

  20. Influences of renal stone surgeries on renal function; Evaluation of renal function with sup 99m Tc-DMSA renal scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Katayama, Yasushi (Niigata Univ. (Japan). School of Medicine)

    1991-10-01

    From 1984 to 1990, {sup 99m}Tc-DMSA renal scintigraphy was performed before and after nephrolithotomy (15 cases), pyelolithotomy (15 cases), percutaneous nephrolithotripsy (PNL: 15 cases) and extracorporeal shock wave lithotripsy (ESWL: 16 cases, 17 kidneys) in order to evaluate of influences of renal stone surgeries on split renal function. DMSA renal uptake change ratio of treated kidneys of nephrolithotomy (-24.94{+-}5.60%) was significantly lower than that of PNL (-0.06{+-}3.92%), pyelolithotomy (-4.08{+-}4.79%) (p<0.01) and ESWL (-7.72{+-}3.87%) (p<0.05). The average change ratios of contralateral kidneys were as follows: PNL 4.80{+-}4.21% nephrolithotomy 4.67{+-}4.73%, pyelolithotomy -1.46{+-}5.39% and ESWL -2.02{+-}4.44%. One to 3 weeks after PNL, the cold area on the renal image was found in 10 (66.7%) of 15 cases. In cases of ESWL, DMSA renal uptake decreased even 4-10 weeks (mean 7 weeks) after treatment. In conclusion, possibility of deterioration of renal function after ESWL was suggested. (author).