WorldWideScience

Sample records for sampling measurements demonstrate

  1. Demonstration of Novel Sampling Techniques for Measurement of Turbine Engine Volatile and Non-Volatile Particulate Matter (PM) Emissions

    Science.gov (United States)

    2017-03-06

    WP-201317) Demonstration of Novel Sampling Techniques for Measurement of Turbine Engine Volatile and Non-volatile Particulate Matter (PM... Engine Volatile and Non-Volatile Particulate Matter (PM) Emissions 6. AUTHOR(S) E. Corporan, M. DeWitt, C. Klingshirn, M.D. Cheng, R. Miake-Lye, J. Peck...the performance and viability of two devices to condition aircraft turbine engine exhaust to allow the accurate measurement of total (volatile and non

  2. Demonstration of Novel Sampling Techniques for Measurement of Turbine Engine Volatile and Non-Volatile Particulate Matter (PM) Emissions

    Science.gov (United States)

    2015-12-30

    emissions demonstration . 46 6 Figure 24. T63 engine with extension pipe to direct exhaust outside of the test cell for exhaust sampling with tip...to assess their effectiveness in conditioning turbine engine exhaust for total PM emissions measurements. Both were designed to promote the... effectively control and mitigate PM emissions. Aircraft PM is formed in the engine combustor due to incomplete combustion of fuel, and in the

  3. Gaseous radiocarbon measurements of small samples

    International Nuclear Information System (INIS)

    Ruff, M.; Szidat, S.; Gaeggeler, H.W.; Suter, M.; Synal, H.-A.; Wacker, L.

    2010-01-01

    Radiocarbon dating by means of accelerator mass spectrometry (AMS) is a well-established method for samples containing carbon in the milligram range. However, the measurement of small samples containing less than 50 μg carbon often fails. It is difficult to graphitise these samples and the preparation is prone to contamination. To avoid graphitisation, a solution can be the direct measurement of carbon dioxide. The MICADAS, the smallest accelerator for radiocarbon dating in Zurich, is equipped with a hybrid Cs sputter ion source. It allows the measurement of both, graphite targets and gaseous CO 2 samples, without any rebuilding. This work presents experiences dealing with small samples containing 1-40 μg carbon. 500 unknown samples of different environmental research fields have been measured yet. Most of the samples were measured with the gas ion source. These data are compared with earlier measurements of small graphite samples. The performance of the two different techniques is discussed and main contributions to the blank determined. An analysis of blank and standard data measured within years allowed a quantification of the contamination, which was found to be of the order of 55 ng and 750 ng carbon (50 pMC) for the gaseous and the graphite samples, respectively. For quality control, a number of certified standards were measured using the gas ion source to demonstrate reliability of the data.

  4. Advances in Radiocarbon Measurement of Water Samples

    Energy Technology Data Exchange (ETDEWEB)

    Janovics, R.; Molnar, M.; Major, I. [Institute of Nuclear Research (ATO MKI), Hungarian Academy of Sciences, H-4001 Debrecen (Hungary); Svetlik, I. [Department of Radiation Dosimetry, Nuclear Physics Institute AS CR, Prague (Czech Republic); Wacker, L. [Institute for Particle Physics, ETH Hoenggerberg, Zuerich (Switzerland)

    2013-07-15

    In this paper two very different and novel methods for the {sup 14}C measurement of water samples are presented. The first method uses direct absorption into a scintillation cocktail and a following liquid scintillation measurement. Typical sample size is 20-40 L and overall uncertainty is {+-} 2% for modern samples. It is a very cost effective and easy to use method based on a novel and simple static absorption process for the CO{sub 2} extracted from groundwater. The other very sensitive method is based on accelerator mass spectrometry (AMS) using a gas ion source. With a MICADAS type AMS system we demonstrated that you can routinely measure the {sup 14}C content of 1 mL of water sample with better than 1% precision (for a modern sample). This direct {sup 14}C AMS measurement of water takes less than 20 minutes including sample preparation. (author)

  5. A Fault Sample Simulation Approach for Virtual Testability Demonstration Test

    Institute of Scientific and Technical Information of China (English)

    ZHANG Yong; QIU Jing; LIU Guanjun; YANG Peng

    2012-01-01

    Virtual testability demonstration test has many advantages,such as low cost,high efficiency,low risk and few restrictions.It brings new requirements to the fault sample generation.A fault sample simulation approach for virtual testability demonstration test based on stochastic process theory is proposed.First,the similarities and differences of fault sample generation between physical testability demonstration test and virtual testability demonstration test are discussed.Second,it is pointed out that the fault occurrence process subject to perfect repair is renewal process.Third,the interarrival time distribution function of the next fault event is given.Steps and flowcharts of fault sample generation are introduced.The number of faults and their occurrence time are obtained by statistical simulation.Finally,experiments are carried out on a stable tracking platform.Because a variety of types of life distributions and maintenance modes are considered and some assumptions are removed,the sample size and structure of fault sample simulation results are more similar to the actual results and more reasonable.The proposed method can effectively guide the fault injection in virtual testability demonstration test.

  6. STATISTICAL EVALUATION OF SMALL SCALE MIXING DEMONSTRATION SAMPLING AND BATCH TRANSFER PERFORMANCE - 12093

    Energy Technology Data Exchange (ETDEWEB)

    GREER DA; THIEN MG

    2012-01-12

    The ability to effectively mix, sample, certify, and deliver consistent batches of High Level Waste (HLW) feed from the Hanford Double Shell Tanks (DST) to the Waste Treatment and Immobilization Plant (WTP) presents a significant mission risk with potential to impact mission length and the quantity of HLW glass produced. DOE's Tank Operations Contractor, Washington River Protection Solutions (WRPS) has previously presented the results of mixing performance in two different sizes of small scale DSTs to support scale up estimates of full scale DST mixing performance. Currently, sufficient sampling of DSTs is one of the largest programmatic risks that could prevent timely delivery of high level waste to the WTP. WRPS has performed small scale mixing and sampling demonstrations to study the ability to sufficiently sample the tanks. The statistical evaluation of the demonstration results which lead to the conclusion that the two scales of small DST are behaving similarly and that full scale performance is predictable will be presented. This work is essential to reduce the risk of requiring a new dedicated feed sampling facility and will guide future optimization work to ensure the waste feed delivery mission will be accomplished successfully. This paper will focus on the analytical data collected from mixing, sampling, and batch transfer testing from the small scale mixing demonstration tanks and how those data are being interpreted to begin to understand the relationship between samples taken prior to transfer and samples from the subsequent batches transferred. An overview of the types of data collected and examples of typical raw data will be provided. The paper will then discuss the processing and manipulation of the data which is necessary to begin evaluating sampling and batch transfer performance. This discussion will also include the evaluation of the analytical measurement capability with regard to the simulant material used in the demonstration tests. The

  7. Policy Analysis Screening System (PASS) demonstration: sample queries and terminal instructions

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-10-16

    This document contains the input and output for the Policy Analysis Screening System (PASS) demonstration. This demonstration is stored on a portable disk at the Environmental Impacts Division. Sample queries presented here include: (1) how to use PASS; (2) estimated 1995 energy consumption from Mid-Range Energy-Forecasting System (MEFS) data base; (3) pollution projections from Strategic Environmental Assessment System (SEAS) data base; (4) diesel auto regulations; (5) diesel auto health effects; (6) oil shale health and safety measures; (7) water pollution effects of SRC; (8) acid rainfall from Energy Environmental Statistics (EES) data base; 1990 EIA electric generation by fuel type; sulfate concentrations by Federal region; forecast of 1995 SO/sub 2/ emissions in Region III; and estimated electrical generating capacity in California to 1990. The file name for each query is included.

  8. SEAMIST trademark in-situ instrumentation and vapor sampling system applications in the Sandia Mixed Waste Landfill Integrated Demonstration Program

    International Nuclear Information System (INIS)

    Lowry, W.E.; Dunn, S.D.; Cremer, S.C.; Williams, C.

    1994-01-01

    The SEAMIST trademark inverting membrane deployment system has been used successfully at the Mixed Waste Landfill Integrated Demonstration (MWLID) for multipoint vapor sampling/pressure measurement/permeability measurement/sensor integration demonstrations and borehole lining. Several instruments were deployed inside the SEAMIST trademark lined boreholes to detect metals, radionuclides, moisture, and geologic variations. The liner protected the instruments from contamination, maintained support of the uncased borehole wall, and sealed the total borehole from air circulation. The current activities have included the installation of three multipoint vapor sampling systems and sensor integration systems in 100-foot-deep vertical boreholes. A long term pressure monitoring program has recorded barometric pressure effects at depth with relatively high spatial resolution. The SEAMIST trademark system has been integrated with a variety of hydrologic and chemical sensors for in-situ measurements, demonstrating its versatility as an instrument deployment system which allows easy emplacement and removal. Standard SEAMIST trademark vapor sampling systems were also integrated with state-of-the-art VOC analysis technologies (automated GC, UV laser fluorometer). The results and status of these demonstration tests are presented

  9. Plutonium measurements in Hanford DOE site waste samples

    International Nuclear Information System (INIS)

    Dewberry, R.A.; Boyce, W.T.

    1999-01-01

    Development work to prepare a method to measure absolute 239 Pu content and Pu-isotopics by ICP-MS in acidified Hanford DOE-site samples which are very high in 90 Sr, 99 Tc, and 137 Cs radioactivity and which are frequently high in organic carbon content is described. Samples with very large 90 Sr and 137 Cs contents have historically been difficult to analyze for Pu content by each of three alpha-counting techniques in use at SRS, and analysis by ICP-MS in these samples is complicated by the high organics content. An ion exchange chemical preparation is reported to obtain fraction of Pu that does not contain any fission product contribution and no interfering organics to allow measure of absolute 239 Pu and of 239 Pu through 241 Pu isotopics by ICP-MS. The method uses a 242 Pu spike to measure Pu recovery and is demonstrated in this paper with three distinct commercially available resins and with over 300 samples. Measured absolute 239 Pu contents in sixty-three spiked/unspiked duplicates have agreed within 15% precision. Overall 242 Pu recoveries were near 90% with 25% precision. Comparisons of absolute 239 Pu contents measured directly on three samples agreed within the quoted 25% uncertainty. (author)

  10. Study of probe-sample distance for biomedical spectra measurement

    Directory of Open Access Journals (Sweden)

    Li Lei

    2011-11-01

    Full Text Available Abstract Background Fiber-based optical spectroscopy has been widely used for biomedical applications. However, the effect of probe-sample distance on the collection efficiency has not been well investigated. Method In this paper, we presented a theoretical model to maximize the illumination and collection efficiency in designing fiber optic probes for biomedical spectra measurement. This model was in general applicable to probes with single or multiple fibers at an arbitrary incident angle. In order to demonstrate the theory, a fluorescence spectrometer was used to measure the fluorescence of human finger skin at various probe-sample distances. The fluorescence spectrum and the total fluorescence intensity were recorded. Results The theoretical results show that for single fiber probes, contact measurement always provides the best results. While for multi-fiber probes, there is an optimal probe distance. When a 400- μm excitation fiber is used to deliver the light to the skin and another six 400- μm fibers surrounding the excitation fiber are used to collect the fluorescence signal, the experimental results show that human finger skin has very strong fluorescence between 475 nm and 700 nm under 450 nm excitation. The fluorescence intensity is heavily dependent on the probe-sample distance and there is an optimal probe distance. Conclusions We investigated a number of probe-sample configurations and found that contact measurement could be the primary choice for single-fiber probes, but was very inefficient for multi-fiber probes. There was an optimal probe-sample distance for multi-fiber probes. By carefully choosing the probe-sample distance, the collection efficiency could be enhanced by 5-10 times. Our experiments demonstrated that the experimental results of the probe-sample distance dependence of collection efficiency in multi-fiber probes were in general agreement with our theory.

  11. Small Scale Mixing Demonstration Batch Transfer and Sampling Performance of Simulated HLW - 12307

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Jesse; Townson, Paul; Vanatta, Matt [EnergySolutions, Engineering and Technology Group, Richland, WA, 99354 (United States)

    2012-07-01

    The ability to effectively mix, sample, certify, and deliver consistent batches of High Level Waste (HLW) feed from the Hanford Double Shell Tanks (DST) to the Waste treatment Plant (WTP) has been recognized as a significant mission risk with potential to impact mission length and the quantity of HLW glass produced. At the end of 2009 DOE's Tank Operations Contractor, Washington River Protection Solutions (WRPS), awarded a contract to EnergySolutions to design, fabricate and operate a demonstration platform called the Small Scale Mixing Demonstration (SSMD) to establish pre-transfer sampling capacity, and batch transfer performance data at two different scales. This data will be used to examine the baseline capacity for a tank mixed via rotational jet mixers to transfer consistent or bounding batches, and provide scale up information to predict full scale operational performance. This information will then in turn be used to define the baseline capacity of such a system to transfer and sample batches sent to WTP. The Small Scale Mixing Demonstration (SSMD) platform consists of 43'' and 120'' diameter clear acrylic test vessels, each equipped with two scaled jet mixer pump assemblies, and all supporting vessels, controls, services, and simulant make up facilities. All tank internals have been modeled including the air lift circulators (ALCs), the steam heating coil, and the radius between the wall and floor. The test vessels are set up to simulate the transfer of HLW out of a mixed tank, and collect a pre-transfer sample in a manner similar to the proposed baseline configuration. The collected material is submitted to an NQA-1 laboratory for chemical analysis. Previous work has been done to assess tank mixing performance at both scales. This work involved a combination of unique instruments to understand the three dimensional distribution of solids using a combination of Coriolis meter measurements, in situ chord length distribution

  12. Improvements to sample processing and measurement to enable more widespread environmental application of tritium

    Energy Technology Data Exchange (ETDEWEB)

    Moran, James; Alexander, Thomas; Aalseth, Craig; Back, Henning; Mace, Emily; Overman, Cory; Seifert, Allen; Freeburg, Wilcox

    2017-08-01

    Previous measurements have demonstrated the wealth of information that tritium (T) can provide on environmentally relevant processes. We present modifications to sample preparation approaches that enable T measurement by proportional counting on small sample sizes equivalent to 120 mg of water and demonstrate the accuracy of these methods on a suite of standardized water samples. This enhanced method should provide the analytical flexibility needed to address persistent knowledge gaps in our understanding of T behavior in the environment.

  13. Analogue demonstration of a high temperature superconducting sigma-delta modulator with 27 GHz sampling

    Energy Technology Data Exchange (ETDEWEB)

    Forrester, M.G.; Hunt, B.D.; Miller, D.L.; Talvacchio, J.; Young, R.M. [Northrop Grumman Science and Technology Center, Pittsburgh, PA 15235-5098 (United States)

    1999-11-01

    We have successfully fabricated and tested a high temperature superconducting (HTS) sigma-delta modulator for analogue-to-digital conversion. This is the first demonstration of a GHz sampling A-to-D in HTS. The 15-junction single-flux-quantum (SFQ) circuit, fabricated using an epitaxial multilayer HTS process with YBCO/Co-YBCO/YBCO edge junctions, was internally clocked at 27 GHz and used to convert a 5.01 MHz signal. The modulator demonstrated a spur-free dynamic range of more than 75 dB. Two-tone measurements with 5.01 MHz and 5.51 MHz signals demonstrated third-order intermodulation products to be lower than -59 dBc. Demonstration of a functional HTS modulator represents a significant milestone in the development of high dynamic range ADCs suitable for such applications as surveillance radar. (author)

  14. Improvements to sample processing and measurement to enable more widespread environmental application of tritium.

    Science.gov (United States)

    Moran, James; Alexander, Thomas; Aalseth, Craig; Back, Henning; Mace, Emily; Overman, Cory; Seifert, Allen; Freeburg, Wilcox

    2017-08-01

    Previous measurements have demonstrated the wealth of information that tritium (T) can provide on environmentally relevant processes. We present modifications to sample preparation approaches that enable T measurement by proportional counting on small sample sizes equivalent to 120mg of water and demonstrate the accuracy of these methods on a suite of standardized water samples. We identify a current quantification limit of 92.2 TU which, combined with our small sample sizes, correlates to as little as 0.00133Bq of total T activity. This enhanced method should provide the analytical flexibility needed to address persistent knowledge gaps in our understanding of both natural and artificial T behavior in the environment. Copyright © 2017. Published by Elsevier Ltd.

  15. Demonstrating Reliable High Level Waste Slurry Sampling Techniques to Support Hanford Waste Processing

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, Steven E.

    2013-11-11

    The Hanford Tank Operations Contractor (TOC) and the Hanford Waste Treatment and Immobilization Plant (WTP) contractor are both engaged in demonstrating mixing, sampling, and transfer system capability using simulated Hanford High-Level Waste (HL W) formulations. This work represents one of the remaining technical issues with the high-level waste treatment mission at Hanford. The TOC must demonstrate the ability to adequately mix and sample high-level waste feed to meet the WTP Waste Acceptance Criteria and Data Quality Objectives. The sampling method employed must support both TOC and WTP requirements. To facilitate information transfer between the two facilities the mixing and sampling demonstrations are led by the One System Integrated Project Team. The One System team, Waste Feed Delivery Mixing and Sampling Program, has developed a full scale sampling loop to demonstrate sampler capability. This paper discusses the full scale sampling loops ability to meet precision and accuracy requirements, including lessons learned during testing. Results of the testing showed that the Isolok(R) sampler chosen for implementation provides precise, repeatable results. The Isolok(R) sampler accuracy as tested did not meet test success criteria. Review of test data and the test platform following testing by a sampling expert identified several issues regarding the sampler used to provide reference material used to judge the Isolok's accuracy. Recommendations were made to obtain new data to evaluate the sampler's accuracy utilizing a reference sampler that follows good sampling protocol.

  16. Demonstrating Reliable High Level Waste Slurry Sampling Techniques to Support Hanford Waste Processing

    International Nuclear Information System (INIS)

    Kelly, Steven E.

    2013-01-01

    The Hanford Tank Operations Contractor (TOC) and the Hanford Waste Treatment and Immobilization Plant (WTP) contractor are both engaged in demonstrating mixing, sampling, and transfer system capability using simulated Hanford High-Level Waste (HL W) formulations. This work represents one of the remaining technical issues with the high-level waste treatment mission at Hanford. The TOC must demonstrate the ability to adequately mix and sample high-level waste feed to meet the WTP Waste Acceptance Criteria and Data Quality Objectives. The sampling method employed must support both TOC and WTP requirements. To facilitate information transfer between the two facilities the mixing and sampling demonstrations are led by the One System Integrated Project Team. The One System team, Waste Feed Delivery Mixing and Sampling Program, has developed a full scale sampling loop to demonstrate sampler capability. This paper discusses the full scale sampling loops ability to meet precision and accuracy requirements, including lessons learned during testing. Results of the testing showed that the Isolok(R) sampler chosen for implementation provides precise, repeatable results. The Isolok(R) sampler accuracy as tested did not meet test success criteria. Review of test data and the test platform following testing by a sampling expert identified several issues regarding the sampler used to provide reference material used to judge the Isolok's accuracy. Recommendations were made to obtain new data to evaluate the sampler's accuracy utilizing a reference sampler that follows good sampling protocol

  17. Demonstration of a Fast, Precise Propane Measurement Using Infrared Spectroscopy

    Science.gov (United States)

    Zahniser, M. S.; Roscioli, J. R.; Nelson, D. D.; Herndon, S. C.

    2016-12-01

    Propane is one of the primary components of emissions from natural gas extraction and processing activities. In addition to being an air pollutant, its ratio to other hydrocarbons such as methane and ethane can serve as a "fingerprint" of a particular facility or process, aiding in identifying emission sources. Quantifying propane has typically required laboratory analysis of flask samples, resulting in low temporal resolution and making plume-based measurements infeasible. Here we demonstrate fast (1-second), high precision (infrared spectroscopy at 2967 wavenumbers. In addition, we explore the impact of nearby water and ethane absorption lines on the accuracy and precision of the propane measurement. Finally, we discuss development of a dual-laser instrument capable of simultaneous measurements of methane, ethane, and propane (the C1-C3 compounds), all within a small spatial package that can be easily deployed aboard a mobile platform.

  18. Demonstration/Validation of Incremental Sampling at Two Diverse Military Ranges and Development of an Incremental Sampling Tool

    Science.gov (United States)

    2010-06-01

    Sampling (MIS)? • Technique of combining many increments of soil from a number of points within exposure area • Developed by Enviro Stat (Trademarked...Demonstrating a reliable soil sampling strategy to accurately characterize contaminant concentrations in spatially extreme and heterogeneous...into a set of decision (exposure) units • One or several discrete or small- scale composite soil samples collected to represent each decision unit

  19. Stochastic bounded consensus tracking of leader-follower multi-agent systems with measurement noises based on sampled data with general sampling delay

    International Nuclear Information System (INIS)

    Wu Zhi-Hai; Peng Li; Xie Lin-Bo; Wen Ji-Wei

    2013-01-01

    In this paper we provide a unified framework for consensus tracking of leader-follower multi-agent systems with measurement noises based on sampled data with a general sampling delay. First, a stochastic bounded consensus tracking protocol based on sampled data with a general sampling delay is presented by employing the delay decomposition technique. Then, necessary and sufficient conditions are derived for guaranteeing leader-follower multi-agent systems with measurement noises and a time-varying reference state to achieve mean square bounded consensus tracking. The obtained results cover no sampling delay, a small sampling delay and a large sampling delay as three special cases. Last, simulations are provided to demonstrate the effectiveness of the theoretical results. (interdisciplinary physics and related areas of science and technology)

  20. Method to make accurate concentration and isotopic measurements for small gas samples

    Science.gov (United States)

    Palmer, M. R.; Wahl, E.; Cunningham, K. L.

    2013-12-01

    Carbon isotopic ratio measurements of CO2 and CH4 provide valuable insight into carbon cycle processes. However, many of these studies, like soil gas, soil flux, and water head space experiments, provide very small gas sample volumes, too small for direct measurement by current constant-flow Cavity Ring-Down (CRDS) isotopic analyzers. Previously, we addressed this issue by developing a sample introduction module which enabled the isotopic ratio measurement of 40ml samples or smaller. However, the system, called the Small Sample Isotope Module (SSIM), does dilute the sample during the delivery with inert carrier gas which causes a ~5% reduction in concentration. The isotopic ratio measurements are not affected by this small dilution, but researchers are naturally interested accurate concentration measurements. We present the accuracy and precision of a new method of using this delivery module which we call 'double injection.' Two portions of the 40ml of the sample (20ml each) are introduced to the analyzer, the first injection of which flushes out the diluting gas and the second injection is measured. The accuracy of this new method is demonstrated by comparing the concentration and isotopic ratio measurements for a gas sampled directly and that same gas measured through the SSIM. The data show that the CO2 concentration measurements were the same within instrument precision. The isotopic ratio precision (1σ) of repeated measurements was 0.16 permil for CO2 and 1.15 permil for CH4 at ambient concentrations. This new method provides a significant enhancement in the information provided by small samples.

  1. Mounting Thin Samples For Electrical Measurements

    Science.gov (United States)

    Matus, L. G.; Summers, R. L.

    1988-01-01

    New method for mounting thin sample for electrical measurements involves use of vacuum chuck to hold a ceramic mounting plate, which holds sample. Contacts on mounting plate establish electrical connection to sample. Used to make electrical measurements over temperature range from 77 to 1,000 K and does not introduce distortions into magnetic field during Hall measurements.

  2. An inter-laboratory comparison of urinary 3-hydroxypropylmercapturic acid measurement demonstrates good reproducibility between laboratories

    Directory of Open Access Journals (Sweden)

    Bailey Brian

    2011-10-01

    Full Text Available Abstract Background Biomarkers have been used extensively in clinical studies to assess toxicant exposure in smokers and non-smokers and have recently been used in the evaluation of novel tobacco products. The urinary metabolite 3-HPMA, a metabolite of the major tobacco smoke toxicity contributor acrolein, is one example of a biomarker used to measure exposure to tobacco smoke. A number of laboratories have developed liquid chromatography with tandem mass spectrometry (LC-MS/MS based methods to measure urinary 3-HPMA; however, it is unclear to what extent the data obtained by these different laboratories are comparable. Findings This report describes an inter-laboratory comparison carried out to evaluate the comparability of 3-HPMA measurement between four laboratories. A common set of spiked and authentic smoker and non-smoker urine samples were used. Each laboratory used their in-house LC-MS/MS method and a common internal standard. A comparison of the repeatability ('r', reproducibility ('R', and coefficient of variation for 3-HPMA demonstrated that within-laboratory variation was consistently lower than between-laboratory variation. The average inter-laboratory coefficient of variation was 7% for fortified urine samples and 16.2% for authentic urine samples. Together, this represents an inter-laboratory variation of 12.2%. Conclusion The results from this first inter-laboratory comparison for the measurement of 3-HPMA in urine demonstrate a reasonably good consensus between laboratories. However, some consistent measurement biases were still observed between laboratories, suggesting that additional work may be required to further reduce the inter-laboratory coefficient of variation.

  3. Development and Demonstration of a Method to Evaluate Bio-Sampling Strategies Using Building Simulation and Sample Planning Software.

    Science.gov (United States)

    Dols, W Stuart; Persily, Andrew K; Morrow, Jayne B; Matzke, Brett D; Sego, Landon H; Nuffer, Lisa L; Pulsipher, Brent A

    2010-01-01

    In an effort to validate and demonstrate response and recovery sampling approaches and technologies, the U.S. Department of Homeland Security (DHS), along with several other agencies, have simulated a biothreat agent release within a facility at Idaho National Laboratory (INL) on two separate occasions in the fall of 2007 and the fall of 2008. Because these events constitute only two realizations of many possible scenarios, increased understanding of sampling strategies can be obtained by virtually examining a wide variety of release and dispersion scenarios using computer simulations. This research effort demonstrates the use of two software tools, CONTAM, developed by the National Institute of Standards and Technology (NIST), and Visual Sample Plan (VSP), developed by Pacific Northwest National Laboratory (PNNL). The CONTAM modeling software was used to virtually contaminate a model of the INL test building under various release and dissemination scenarios as well as a range of building design and operation parameters. The results of these CONTAM simulations were then used to investigate the relevance and performance of various sampling strategies using VSP. One of the fundamental outcomes of this project was the demonstration of how CONTAM and VSP can be used together to effectively develop sampling plans to support the various stages of response to an airborne chemical, biological, radiological, or nuclear event. Following such an event (or prior to an event), incident details and the conceptual site model could be used to create an ensemble of CONTAM simulations which model contaminant dispersion within a building. These predictions could then be used to identify priority area zones within the building and then sampling designs and strategies could be developed based on those zones.

  4. Assessing the validity of parenting measures in a sample of chinese adolescents.

    Science.gov (United States)

    Supple, Andrew J; Peterson, Gary W; Bush, Kevin R

    2004-09-01

    The purpose of this study was to assess the construct validity of adolescent-report parenting behavior measures (primarily derived from the Parental Behavior Measure) in a sample of 480 adolescents from Beijing, China. Results suggest that maternal support, monitoring, and autonomy granting were valid measures when assessing maternal socialization strategies and Chinese adolescent development. Measures of punitiveness and love withdrawal demonstrated limited validity, whereas maternal positive induction demonstrated little validity. The major implications of these results are that measures of "negative" parenting that included physical or psychological manipulations may not have salience for the development of Chinese adolescents. Moreover, researchers and clinicians should question the applicability of instruments and measures designed to assess family process when working with individuals in families from diverse cultural backgrounds. Copyright 2004 American Psychological Association

  5. The effects of spatial sampling choices on MR temperature measurements.

    Science.gov (United States)

    Todd, Nick; Vyas, Urvi; de Bever, Josh; Payne, Allison; Parker, Dennis L

    2011-02-01

    The purpose of this article is to quantify the effects that spatial sampling parameters have on the accuracy of magnetic resonance temperature measurements during high intensity focused ultrasound treatments. Spatial resolution and position of the sampling grid were considered using experimental and simulated data for two different types of high intensity focused ultrasound heating trajectories (a single point and a 4-mm circle) with maximum measured temperature and thermal dose volume as the metrics. It is demonstrated that measurement accuracy is related to the curvature of the temperature distribution, where regions with larger spatial second derivatives require higher resolution. The location of the sampling grid relative temperature distribution has a significant effect on the measured values. When imaging at 1.0 × 1.0 × 3.0 mm(3) resolution, the measured values for maximum temperature and volume dosed to 240 cumulative equivalent minutes (CEM) or greater varied by 17% and 33%, respectively, for the single-point heating case, and by 5% and 18%, respectively, for the 4-mm circle heating case. Accurate measurement of the maximum temperature required imaging at 1.0 × 1.0 × 3.0 mm(3) resolution for the single-point heating case and 2.0 × 2.0 × 5.0 mm(3) resolution for the 4-mm circle heating case. Copyright © 2010 Wiley-Liss, Inc.

  6. Sample-averaged biexciton quantum yield measured by solution-phase photon correlation.

    Science.gov (United States)

    Beyler, Andrew P; Bischof, Thomas S; Cui, Jian; Coropceanu, Igor; Harris, Daniel K; Bawendi, Moungi G

    2014-12-10

    The brightness of nanoscale optical materials such as semiconductor nanocrystals is currently limited in high excitation flux applications by inefficient multiexciton fluorescence. We have devised a solution-phase photon correlation measurement that can conveniently and reliably measure the average biexciton-to-exciton quantum yield ratio of an entire sample without user selection bias. This technique can be used to investigate the multiexciton recombination dynamics of a broad scope of synthetically underdeveloped materials, including those with low exciton quantum yields and poor fluorescence stability. Here, we have applied this method to measure weak biexciton fluorescence in samples of visible-emitting InP/ZnS and InAs/ZnS core/shell nanocrystals, and to demonstrate that a rapid CdS shell growth procedure can markedly increase the biexciton fluorescence of CdSe nanocrystals.

  7. Radioisotope Sample Measurement Techniques in Medicine and Biology. Proceedings of the Symposium on Radioisotope Sample Measurement Techniques

    International Nuclear Information System (INIS)

    1965-01-01

    The medical and biological applications of radioisotopes depend on two basically different types of measurements, those on living subjects in vivo and those on samples in vitro. The International Atomic Energy Agency has in the past held several meetings on in vivo measurement techniques, notably whole-body counting and radioisotope scanning. The present volume contains the Proceedings of the first Symposium the Agency has organized to discuss the various aspects of techniques for sample measurement in vitro. The range of these sample measurement techniques is very wide. The sample may weigh a few milligrams or several hundred grams, and may be in the gaseous, liquid or solid state. Its radioactive content may consist of a single, known radioisotope or several unknown ones. The concentration of radioactivity may be low, medium or high. The measurements may be made manually or automatically and any one of the many radiation detectors now available may be used. The 53 papers presented at the Symposium illustrate the great variety of methods now in use for radioactive- sample measurements. The first topic discussed is gamma-ray spectrometry, which finds an increasing number of applications in sample measurements. Other sections of the Proceedings deal with: the use of computers in gamma-ray spectrometry and multiple tracer techniques; recent developments in activation analysis where both gamma-ray spectrometry and computing techniques are applied; thin-layer and paper radio chromatographic techniques for use with low energy beta-ray emitters; various aspects of liquid scintillation counting techniques in the measurement of alpha- and beta-ray emitters, including chemical and colour quenching; autoradiographic techniques; calibration of equipment; and standardization of radioisotopes. Finally, some applications of solid-state detectors are presented; this section may be regarded as a preview of important future developments. The meeting was attended by 203 participants

  8. Safety analysis report for packaging (onsite) transuranic performance demonstration program sample packaging

    International Nuclear Information System (INIS)

    Mccoy, J.C.

    1997-01-01

    The Transuranic Performance Demonstration Program (TPDP) sample packaging is used to transport highway route controlled quantities of weapons grade (WG) plutonium samples from the Plutonium Finishing Plant (PFP) to the Waste Receiving and Processing (WRAP) facility and back. The purpose of these shipments is to test the nondestructive assay equipment in the WRAP facility as part of the Nondestructive Waste Assay PDP. The PDP is part of the U. S. Department of Energy (DOE) National TRU Program managed by the U. S. Department of Energy, Carlsbad Area Office, Carlsbad, New Mexico. Details of this program are found in CAO-94-1045, Performance Demonstration Program Plan for Nondestructive Assay for the TRU Waste Characterization Program (CAO 1994); INEL-96/0129, Design of Benign Matrix Drums for the Non-Destructive Assay Performance Demonstration Program for the National TRU Program (INEL 1996a); and INEL-96/0245, Design of Phase 1 Radioactive Working Reference Materials for the Nondestructive Assay Performance Demonstration Program for the National TRU Program (INEL 1996b). Other program documentation is maintained by the national TRU program and each DOE site participating in the program. This safety analysis report for packaging (SARP) provides the analyses and evaluations necessary to demonstrate that the TRU PDP sample packaging meets the onsite transportation safety requirements of WHC-CM-2-14, Hazardous Material Packaging and Shipping, for an onsite Transportation Hazard Indicator (THI) 2 packaging. This SARP, however, does not include evaluation of any operations within the PFP or WRAP facilities, including handling, maintenance, storage, or operating requirements, except as they apply directly to transportation between the gate of PFP and the gate of the WRAP facility. All other activities are subject to the requirements of the facility safety analysis reports (FSAR) of the PFP or WRAP facility and requirements of the PDP

  9. Flask sample measurements for CO2, CH4 and CO using cavity ring-down spectrometry

    Science.gov (United States)

    Wang, J.-L.; Jacobson, G.; Rella, C. W.; Chang, C.-Y.; Liu, I.; Liu, W.-T.; Chew, C.; Ou-Yang, C.-F.; Liao, W.-C.; Chang, C.-C.

    2013-08-01

    In recent years, cavity ring-down spectrometry (CRDS) has been demonstrated to be a highly sensitive, stable and fast analytical technique for real-time in situ measurements of greenhouse gases. In this study, we propose the technique (which we call flask-CRDS) of analyzing whole air flask samples for CO2, CH4 and CO using a custom gas manifold designed to connect to a CRDS analyzer. Extremely stable measurements of these gases can be achieved over a large pressure range in the flask, from 175 to 760 Torr. The wide pressure range is conducive to flask sample measurement in three ways: (1) flask samples can be collected in low-pressure environments (e.g. high-altitude locations); (2) flask samples can be first analyzed for other trace gases with the remaining low-pressure sample for CRDS analysis of CO2, CH4 and CO; and (3) flask samples can be archived and re-analyzed for validation. The repeatability of this method (1σ of 0.07 ppm for CO2, 0.4 ppb for CH4, and 0.5 ppb for CO) was assessed by analyzing five canisters filled with the same air sample to a pressure of 200 Torr. An inter-comparison of the flask-CRDS data with in-situ CRDS measurements at a high-altitude mountain baseline station revealed excellent agreement, with differences of 0.10 ± 0.09 ppm (1σ) for CO2 and 0.9 ± 1.0 ppb for CH4. This study demonstrated that the flask-CRDS method was not only simple to build and operate but could also perform highly accurate and precise measurements of atmospheric CO2, CH4 and CO in flask samples.

  10. Development and Demonstration of a Method to Evaluate Bio-Sampling Strategies Using Building Simulation and Sample Planning Software

    OpenAIRE

    Dols, W. Stuart; Persily, Andrew K.; Morrow, Jayne B.; Matzke, Brett D.; Sego, Landon H.; Nuffer, Lisa L.; Pulsipher, Brent A.

    2010-01-01

    In an effort to validate and demonstrate response and recovery sampling approaches and technologies, the U.S. Department of Homeland Security (DHS), along with several other agencies, have simulated a biothreat agent release within a facility at Idaho National Laboratory (INL) on two separate occasions in the fall of 2007 and the fall of 2008. Because these events constitute only two realizations of many possible scenarios, increased understanding of sampling strategies can be obtained by vir...

  11. Demonstration of measurement-only blind quantum computing

    Science.gov (United States)

    Greganti, Chiara; Roehsner, Marie-Christine; Barz, Stefanie; Morimae, Tomoyuki; Walther, Philip

    2016-01-01

    Blind quantum computing allows for secure cloud networks of quasi-classical clients and a fully fledged quantum server. Recently, a new protocol has been proposed, which requires a client to perform only measurements. We demonstrate a proof-of-principle implementation of this measurement-only blind quantum computing, exploiting a photonic setup to generate four-qubit cluster states for computation and verification. Feasible technological requirements for the client and the device-independent blindness make this scheme very applicable for future secure quantum networks.

  12. Exact sampling of the unobserved covariates in Bayesian spline models for measurement error problems.

    Science.gov (United States)

    Bhadra, Anindya; Carroll, Raymond J

    2016-07-01

    In truncated polynomial spline or B-spline models where the covariates are measured with error, a fully Bayesian approach to model fitting requires the covariates and model parameters to be sampled at every Markov chain Monte Carlo iteration. Sampling the unobserved covariates poses a major computational problem and usually Gibbs sampling is not possible. This forces the practitioner to use a Metropolis-Hastings step which might suffer from unacceptable performance due to poor mixing and might require careful tuning. In this article we show for the cases of truncated polynomial spline or B-spline models of degree equal to one, the complete conditional distribution of the covariates measured with error is available explicitly as a mixture of double-truncated normals, thereby enabling a Gibbs sampling scheme. We demonstrate via a simulation study that our technique performs favorably in terms of computational efficiency and statistical performance. Our results indicate up to 62 and 54 % increase in mean integrated squared error efficiency when compared to existing alternatives while using truncated polynomial splines and B-splines respectively. Furthermore, there is evidence that the gain in efficiency increases with the measurement error variance, indicating the proposed method is a particularly valuable tool for challenging applications that present high measurement error. We conclude with a demonstration on a nutritional epidemiology data set from the NIH-AARP study and by pointing out some possible extensions of the current work.

  13. Demonstration of measurement-only blind quantum computing

    International Nuclear Information System (INIS)

    Greganti, Chiara; Roehsner, Marie-Christine; Barz, Stefanie; Walther, Philip; Morimae, Tomoyuki

    2016-01-01

    Blind quantum computing allows for secure cloud networks of quasi-classical clients and a fully fledged quantum server. Recently, a new protocol has been proposed, which requires a client to perform only measurements. We demonstrate a proof-of-principle implementation of this measurement-only blind quantum computing, exploiting a photonic setup to generate four-qubit cluster states for computation and verification. Feasible technological requirements for the client and the device-independent blindness make this scheme very applicable for future secure quantum networks. (paper)

  14. Intelligent sampling for the measurement of structured surfaces

    International Nuclear Information System (INIS)

    Wang, J; Jiang, X; Blunt, L A; Scott, P J; Leach, R K

    2012-01-01

    Uniform sampling in metrology has known drawbacks such as coherent spectral aliasing and a lack of efficiency in terms of measuring time and data storage. The requirement for intelligent sampling strategies has been outlined over recent years, particularly where the measurement of structured surfaces is concerned. Most of the present research on intelligent sampling has focused on dimensional metrology using coordinate-measuring machines with little reported on the area of surface metrology. In the research reported here, potential intelligent sampling strategies for surface topography measurement of structured surfaces are investigated by using numerical simulation and experimental verification. The methods include the jittered uniform method, low-discrepancy pattern sampling and several adaptive methods which originate from computer graphics, coordinate metrology and previous research by the authors. By combining the use of advanced reconstruction methods and feature-based characterization techniques, the measurement performance of the sampling methods is studied using case studies. The advantages, stability and feasibility of these techniques for practical measurements are discussed. (paper)

  15. Demonstration/Validation of the Snap Sampler Passive Ground Water Sampling Device

    Science.gov (United States)

    2011-06-01

    purging and sampling protocol. Analytes that were measured at the Pease site included total and dissolved concentrations of arsenic (As), calcium ...samples remain in the original bottle in which they were collected, presumably losses of volatiles and changes in concentrations of dissolved gases or...because of excavation and removal. This has resulted in hydraulically interconnected bedrock and overburden water- bearing zones in much of this area

  16. Demonstration Exercise of a Validated Sample Collection Method for Powders Suspected of Being Biological Agents in Georgia 2006

    International Nuclear Information System (INIS)

    Marsh, B.

    2007-01-01

    August 7, 2006 the state of Georgia conducted a collaborative sampling exercise between the Georgia National Guard 4th Civil Support Team Weapons of Mass Destruction (CST-WMD) and the Georgia Department of Human Resources Division of Public Health demonstrating a recently validated bulk powder sampling method. The exercise was hosted at the Federal Law Enforcement Training Center (FLETC) at Glynn County, Georgia and involved the participation of the Georgia Emergency Management Agency (GEMA), Georgia National Guard, Georgia Public Health Laboratories, the Federal Bureau of Investigation Atlanta Office, Georgia Coastal Health District, and the Glynn County Fire Department. The purpose of the exercise was to demonstrate a recently validated national sampling standard developed by the American Standards and Test Measures (ASTM) International; ASTM E2458 S tandard Practice for Bulk Sample Collection and Swab Sample Collection of Visible Powders Suspected of Being Biological Agents from Nonporous Surfaces . The intent of the exercise was not to endorse the sampling method, but to develop a model for exercising new sampling methods in the context of existing standard operating procedures (SOPs) while strengthening operational relationships between response teams and analytical laboratories. The exercise required a sampling team to respond real-time to an incident cross state involving a clandestine bio-terrorism production lab found within a recreational vehicle (RV). Sample targets consisted of non-viable gamma irradiated B. anthracis Sterne spores prepared by Dugway Proving Ground. Various spore concentration levels were collected by the ASTM method, followed by on- and off-scene analysis utilizing the Center for Disease Control (CDC) Laboratory Response Network (LRN) and National Guard Bureau (NGB) CST mobile Analytical Laboratory Suite (ALS) protocols. Analytical results were compared and detailed surveys of participant evaluation comments were examined. I will

  17. Measurement of neutron activation in concrete samples

    International Nuclear Information System (INIS)

    Zagar, T.; Ravnik, M.

    2000-01-01

    The results of activation studies of ordinary and barytes concrete samples relevant for research reactor decommissioning are given. Five important long-lived radioactive isotopes ( 54 Mn, 60 Co, 65 Zn, 133 Ba, and 152 Eu) were identified from the gamma-ray spectra measured in the irradiated concrete samples. Activation of these samples was also calculated using ORIGEN2 code. Comparison of calculated and measured results is given. (author)

  18. Tritium sampling and measurement

    International Nuclear Information System (INIS)

    Wood, M.J.; McElroy, R.G.; Surette, R.A.; Brown, R.M.

    1993-01-01

    Current methods for sampling and measuring tritium are described. Although the basic techniques have not changed significantly over the last 10 y, there have been several notable improvements in tritium measurement instrumentation. The design and quality of commercial ion-chamber-based and gas-flow-proportional-counter-based tritium monitors for tritium-in-air have improved, an indirect result of fusion-related research in the 1980s. For tritium-in-water analysis, commercial low-level liquid scintillation spectrometers capable of detecting tritium-in-water concentrations as low as 0.65 Bq L-1 for counting times of 500 min are available. The most sensitive method for tritium-in-water analysis is still 3He mass spectrometry. Concentrations as low as 0.35 mBq L-1 can be detected with current equipment. Passive tritium-oxide-in-air samplers are now being used for workplace monitoring and even in some environmental sampling applications. The reliability, convenience, and low cost of passive tritium-oxide-in-air samplers make them attractive options for many monitoring applications. Airflow proportional counters currently under development look promising for measuring tritium-in-air in the presence of high gamma and/or noble gas backgrounds. However, these detectors are currently limited by their poor performance in humidities over 30%. 133 refs

  19. Evaluation of measurement reproducibility using the standard-sites data, 1994 Fernald field characterization demonstration project

    International Nuclear Information System (INIS)

    Rautman, C.A.

    1996-02-01

    The US Department of Energy conducted the 1994 Fernald (Ohio) field characterization demonstration project to evaluate the performance of a group of both industry-standard and proposed alternative technologies in describing the nature and extent of uranium contamination in surficial soils. Detector stability and measurement reproducibility under actual operating conditions encountered in the field is critical to establishing the credibility of the proposed alternative characterization methods. Comparability of measured uranium activities to those reported by conventional, US Environmental Protection Agency (EPA)-certified laboratory methods is also required. The eleven (11) technologies demonstrated included (1) EPA-standard soil sampling and laboratory mass-spectroscopy analyses, and currently-accepted field-screening techniques using (2) sodium-iodide scintillometers, (3) FIDLER low-energy scintillometers, and (4) a field-portable x-ray fluorescence spectrometer. Proposed advanced characterization techniques included (5) alpha-track detectors, (6) a high-energy beta scintillometer, (7) electret ionization chambers, (8) and (9) a high-resolution gamma-ray spectrometer in two different configurations, (10) a field-adapted laser ablation-inductively coupled plasma-atomic emission spectroscopy (ICP-AES) technique, and (11) a long-range alpha detector. Measurement reproducibility and the accuracy of each method were tested by acquiring numerous replicate measurements of total uranium activity at each of two ''standard sites'' located within the main field demonstration area. Meteorological variables including temperature, relative humidity. and 24-hour rainfall quantities were also recorded in conjunction with the standard-sites measurements

  20. Demonstration and Optimization of BNFL's Pulsed Jet Mixing and RFD Sampling Systems Using NCAW Simulant

    International Nuclear Information System (INIS)

    Bontha, J.R.; Golcar, G.R.; Hannigan, N.

    2000-01-01

    The BNFL Inc. flowsheet for the pretreatment and vitrification of the Hanford High Level Tank waste includes the use of several hundred Reverse Flow Diverters (RFDs) for sampling and transferring the radioactive slurries and Pulsed Jet mixers to homogenize or suspend the tank contents. The Pulsed Jet mixing and the RFD sampling devices represent very simple and efficient methods to mix and sample slurries, respectively, using compressed air to achieve the desired operation. The equipment has no moving parts, which makes them very suitable for mixing and sampling highly radioactive wastes. However, the effectiveness of the mixing and sampling systems are yet to be demonstrated when dealing with Hanford slurries, which exhibit a wide range of physical and theological properties. This report describes the results of the testing of BNFL's Pulsed Jet mixing and RFD sampling systems in a 13-ft ID and 15-ft height dish-bottomed tank at Battelle's 336 building high-bay facility using AZ-101/102 simulants containing up to 36-wt% insoluble solids. The specific objectives of the work were to: Demonstrate the effectiveness of the Pulsed Jet mixing system to thoroughly homogenize Hanford-type slurries over a range of solids loading; Minimize/optimize air usage by changing sequencing of the Pulsed Jet mixers or by altering cycle times; and Demonstrate that the RFD sampler can obtain representative samples of the slurry up to the maximum RPP-WTP baseline concentration of 25-wt%

  1. Robust weak measurements on finite samples

    International Nuclear Information System (INIS)

    Tollaksen, Jeff

    2007-01-01

    A new weak measurement procedure is introduced for finite samples which yields accurate weak values that are outside the range of eigenvalues and which do not require an exponentially rare ensemble. This procedure provides a unique advantage in the amplification of small nonrandom signals by minimizing uncertainties in determining the weak value and by minimizing sample size. This procedure can also extend the strength of the coupling between the system and measuring device to a new regime

  2. Device for radioactivity measurement of liquid samples

    International Nuclear Information System (INIS)

    Lamaziere, J.

    1983-01-01

    The device for low activity gamma measurements comprises an automatic changer for sample transfer from a conveyor to a measuring chamber. The conveyor includes a horizontal table were are regularly distributed sample holders. A lift allows a vertical motion of a plate for the exposition in front of a detector [fr

  3. Measurements of plutonium in environmental samples

    International Nuclear Information System (INIS)

    D'Alberti, F.; Risposi, L.

    1996-01-01

    Within the activities connected with the start up of the PETRA Laboratory (Processo per l'Estrazione di Terre Rare ed Attinidi, i.e. process for extraction of rare earths and actinides), the Radiation Protection Unit of the J.R.C.-Ispra has carried out a well planned set of experimental measurements aimed at evaluating the zero point of the isotopes of plutonium in environmental samples by alfa spectrometry. After the International Moratorium in 1963, no release of plutonium has occurred in the environment apart from the burn up of SNAP 9A satellite in April 1964. Since then the plutonium concentration in air and in fallout samples has been continuously decreasing requiring, therefore, optimization of both instrumentation and experimental measurement procedures in order to obtain better sensibilities. In this work, the experimental methodology followed at the J.R.C.-Ispra for measurements of plutonium concentration in air, deposition and soil is described and the plutonium behaviour in these samples is reported and discussed starting from 1961

  4. Measurements of plutonium in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    D' Alberti, F; Risposi, L [Instituto di Fisica Applicata, University of Milan, Milan (Italy)

    1996-01-01

    Within the activities connected with the start up of the PETRA Laboratory (Processo per l'Estrazione di Terre Rare ed Attinidi, i.e. process for extraction of rare earths and actinides), the Radiation Protection Unit of the J.R.C.-Ispra has carried out a well planned set of experimental measurements aimed at evaluating the zero point of the isotopes of plutonium in environmental samples by alfa spectrometry. After the International Moratorium in 1963, no release of plutonium has occurred in the environment apart from the burn up of SNAP 9A satellite in April 1964. Since then the plutonium concentration in air and in fallout samples has been continuously decreasing requiring, therefore, optimization of both instrumentation and experimental measurement procedures in order to obtain better sensibilities. In this work, the experimental methodology followed at the J.R.C.-Ispra for measurements of plutonium concentration in air, deposition and soil is described and the plutonium behaviour in these samples is reported and discussed starting from 1961.

  5. Measurement of extremely (2) H-enriched water samples by laser spectrometry: application to batch electrolytic concentration of environmental tritium samples.

    Science.gov (United States)

    Wassenaar, L I; Kumar, B; Douence, C; Belachew, D L; Aggarwal, P K

    2016-02-15

    Natural water samples artificially or experimentally enriched in deuterium ((2) H) at concentrations up to 10,000 ppm are required for various medical, environmental and hydrological tracer applications, but are difficult to measure using conventional stable isotope ratio mass spectrometry. Here we demonstrate that off-axis integrated cavity output (OA-ICOS) laser spectrometry, along with (2) H-enriched laboratory calibration standards and appropriate analysis templates, allows for low-cost, fast, and accurate determinations of water samples having δ(2) HVSMOW-SLAP values up to at least 57,000 ‰ (~9000 ppm) at a processing rate of 60 samples per day. As one practical application, extremely (2) H-enriched samples were measured by laser spectrometry and compared to the traditional (3) H Spike-Proxy method in order to determine tritium enrichment factors in the batch electrolysis of environmental waters. Highly (2) H-enriched samples were taken from different sets of electrolytically concentrated standards and low-level (tritium samples, and all cases returned accurate and precise initial low-level (3) H results. The ability to quickly and accurately measure extremely (2) H-enriched waters by laser spectrometry will facilitate the use of deuterium as a tracer in numerous environmental and other applications. For low-level tritium operations, this new analytical ability facilitated a 10-20 % increase in sample productivity through the elimination of spike standards and gravimetrics, and provides immediate feedback on electrolytic enrichment cell performance. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  6. International Interlaboratory Digital PCR Study Demonstrating High Reproducibility for the Measurement of a Rare Sequence Variant.

    Science.gov (United States)

    Whale, Alexandra S; Devonshire, Alison S; Karlin-Neumann, George; Regan, Jack; Javier, Leanne; Cowen, Simon; Fernandez-Gonzalez, Ana; Jones, Gerwyn M; Redshaw, Nicholas; Beck, Julia; Berger, Andreas W; Combaret, Valérie; Dahl Kjersgaard, Nina; Davis, Lisa; Fina, Frederic; Forshew, Tim; Fredslund Andersen, Rikke; Galbiati, Silvia; González Hernández, Álvaro; Haynes, Charles A; Janku, Filip; Lacave, Roger; Lee, Justin; Mistry, Vilas; Pender, Alexandra; Pradines, Anne; Proudhon, Charlotte; Saal, Lao H; Stieglitz, Elliot; Ulrich, Bryan; Foy, Carole A; Parkes, Helen; Tzonev, Svilen; Huggett, Jim F

    2017-02-07

    This study tested the claim that digital PCR (dPCR) can offer highly reproducible quantitative measurements in disparate laboratories. Twenty-one laboratories measured four blinded samples containing different quantities of a KRAS fragment encoding G12D, an important genetic marker for guiding therapy of certain cancers. This marker is challenging to quantify reproducibly using quantitative PCR (qPCR) or next generation sequencing (NGS) due to the presence of competing wild type sequences and the need for calibration. Using dPCR, 18 laboratories were able to quantify the G12D marker within 12% of each other in all samples. Three laboratories appeared to measure consistently outlying results; however, proper application of a follow-up analysis recommendation rectified their data. Our findings show that dPCR has demonstrable reproducibility across a large number of laboratories without calibration. This could enable the reproducible application of molecular stratification to guide therapy and, potentially, for molecular diagnostics.

  7. Aerial sampling using drones for measuring trace gases

    Science.gov (United States)

    Chang, Chih-Chung; Wang, Jia-Lin; Chang, Chih-Yuan; Lin, Ming-Ren; Ou-Yang, Chang-Feng; Pan, Xiang-Xu; Lin, Neng-Huei

    2017-04-01

    Aerial and ground-level samples were simultaneously collected at the northern tip of Taiwan, Cape Fuguei, which is commonly served as a receptor site to receive air parcels from East Asia, Asian continent, the northwest Pacific Ocean and the island of Taiwan itself. Both aerial and surface samples were analyzed for 106 volatile organic compounds (VOCs) and divided into three categories as follows: 1. the total concentrations of 106 VOC (T-VOC) at 300-m height that are lower than the T-VOC level at the surface (Category A), 2. T-VOC concentrations at 300-m that are higher than those at the surface (Category B), and 3. comparable concentrations (Category C). Ten VOCs were exploited as tracers for a variety of emission sources linking to possible sources and transport routes of airborne pollutants. The first two categories A and B showed significant differences in the observed composition and concentrations of tracers between aerial and ground-level samples, implying that the pollutants at different heights may have resulted from different sources and poor air mixing, despite only a 300-m difference in vertical height. In contrast, Category C showed good vertical mixing, as indicated by the comparable concentrations between the aerial and surface measurements. Since the three categories occurred in specific meteorological conditions (between, prior to, and after cold fronts), respectively, it suggests that varied prevailing meteorology controlled the distribution and transport of airborne pollutants. Unlike sampling commonly performed at the surface, this study uses aerial sampling to demonstrate that layered structures under different meteorological conditions. Sampling aloft in lower boundary layer avoids samples being over-influenced by the close-by surface sources such as traffic to reveal signatures of a broader region.

  8. Sampling and measurement of long-lived radionuclides in environmental samples

    International Nuclear Information System (INIS)

    Brauer, F.P.; Goles, R.W.; Kaye, J.H.; Rieck, H.G. Jr.

    1977-01-01

    The volatile and semivolatile long-lived man-made radionuclides 3 H, 14 C, 79 Se, 85 Kr, 99 Tc, 129 I, 135 Cs, and 137 Cs are of concern in operation of nuclear facilities because they are difficult and expensive to contain and once emitted to the environment they become permanent ecological constituents with both local and global distributions. Species-selective sampling and analytical methods (radiochemical, neutron activation, and mass spectrometric) have been developed for many of these nuclides with sensitivities well below those required for radiation protection. These sampling and analytical methods have been applied to the measurement of current environmental levels of some of the more ecologically important radionuclides. The detection and tracing of long-lived radionuclides is being conducted in order to establish base-line values and to study environmental behavior. This paper describes detection and measurement techniques and summarizes current measurement results

  9. Simultaneous measurement of group refractive index and thickness of optical samples using optical coherence tomography

    International Nuclear Information System (INIS)

    Cheng, Hsu-Chih; Liu, Yi-Cheng

    2010-01-01

    Optical coherence tomography (OCT), based on a Michelson interferometer and utilizing low coherence light as the optical source, is a novel technique for the noninvasive imaging of optical scattering media. A simple OCT scheme based on a 3x3 fiber coupler is presented for the simultaneous measurement of the refractive index and thickness of optical samples. The proposed system enables the refractive index and thickness to be determined without any prior knowledge of the sample parameters and is characterized by a simple and compact configuration, a straightforward measurement procedure, and a low cost. The feasibility of the proposed approach is demonstrated experimentally using BK7 and B270 optical glass samples.

  10. Demonstrating Heisenberg-limited unambiguous phase estimation without adaptive measurements

    International Nuclear Information System (INIS)

    Higgins, B L; Wiseman, H M; Pryde, G J; Berry, D W; Bartlett, S D; Mitchell, M W

    2009-01-01

    We derive, and experimentally demonstrate, an interferometric scheme for unambiguous phase estimation with precision scaling at the Heisenberg limit that does not require adaptive measurements. That is, with no prior knowledge of the phase, we can obtain an estimate of the phase with a standard deviation that is only a small constant factor larger than the minimum physically allowed value. Our scheme resolves the phase ambiguity that exists when multiple passes through a phase shift, or NOON states, are used to obtain improved phase resolution. Like a recently introduced adaptive technique (Higgins et al 2007 Nature 450 393), our experiment uses multiple applications of the phase shift on single photons. By not requiring adaptive measurements, but rather using a predetermined measurement sequence, the present scheme is both conceptually simpler and significantly easier to implement. Additionally, we demonstrate a simplified adaptive scheme that also surpasses the standard quantum limit for single passes.

  11. Witness sample preparation for measuring antireflection coatings.

    Science.gov (United States)

    Willey, Ronald R

    2014-02-01

    Measurement of antireflection coating of witness samples from across the worldwide industry has been shown to have excess variability from a sampling taken for the OSA Topical Meeting on Optical Interference Coatings: Measurement Problem. Various sample preparation techniques have been discussed with their limitations, and a preferred technique is recommended with its justification, calibration procedures, and limitations. The common practice of grinding the second side to reduce its reflection is less than satisfactory. One recommended practice is to paint the polished second side, which reduces its reflection to almost zero. A method to evaluate the suitability of given paints is also described.

  12. NWIS casting measurements taken during demonstrations to Russian visitors

    International Nuclear Information System (INIS)

    Mullens, J.A.; Valentine, T.E.; Mihalczo, J.T.

    1998-01-01

    This report describes a set of NWIS measurements made during demonstrations to Russian visitors on August 28, 1997. These measurements will be given to the Russian visitors from Arzamus-16 as part of their NWIS training (part of a DOE laboratory-to-laboratory exchange program). These measurements are made on standard highly enriched Uranium annular castings (as used for storage). Associated NWIS calibration runs were made in air (no casting, just the NWIS Californium source and detectors)

  13. Effect of measurement error budgets and hybrid metrology on qualification metrology sampling

    Science.gov (United States)

    Sendelbach, Matthew; Sarig, Niv; Wakamoto, Koichi; Kim, Hyang Kyun (Helen); Isbester, Paul; Asano, Masafumi; Matsuki, Kazuto; Osorio, Carmen; Archie, Chas

    2014-10-01

    Until now, metrologists had no statistics-based method to determine the sampling needed for an experiment before the start that accuracy experiment. We show a solution to this problem called inverse total measurement uncertainty (TMU) analysis, by presenting statistically based equations that allow the user to estimate the needed sampling after providing appropriate inputs, allowing him to make important "risk versus reward" sampling, cost, and equipment decisions. Application examples using experimental data from scatterometry and critical dimension scanning electron microscope tools are used first to demonstrate how the inverse TMU analysis methodology can be used to make intelligent sampling decisions and then to reveal why low sampling can lead to unstable and misleading results. One model is developed that can help experimenters minimize sampling costs. A second cost model reveals the inadequacy of some current sampling practices-and the enormous costs associated with sampling that provides reasonable levels of certainty in the result. We introduce the strategies on how to manage and mitigate these costs and begin the discussion on how fabs are able to manufacture devices using minimal reference sampling when qualifying metrology steps. Finally, the relationship between inverse TMU analysis and hybrid metrology is explored.

  14. Development of a magnetic measurement device for thin ribbon samples

    International Nuclear Information System (INIS)

    Sato, Yuta; Todaka, Takashi; Enokizono, Masato

    2008-01-01

    This paper presents a magnetic measurement device for thin ribbon samples, which are produced by rapid cooling technique. This device enables us to measure magnetic properties easily by only inserting a ribbon sample into a sample holder. The sample holder was made by bakelite to fix any width sample. A long solenoid coil was used to generate a uniform magnetic field and the sample holder was placed at the mid part of the solenoid. The magnetic field strength was measured using a shunt resistor and the magnetic flux density and magnetization in sample ribbons were evaluated by using search coils. The accuracy of measurement was verified with an amorphous metal ribbon sample. Next, we have measured magnetic properties of some magnetic shape memory alloys, which have different compositions. The measured results are compared and we clarified the effect of Sm contents on the magnetic properties

  15. Assessing the validity of single-item life satisfaction measures: results from three large samples.

    Science.gov (United States)

    Cheung, Felix; Lucas, Richard E

    2014-12-01

    The present paper assessed the validity of single-item life satisfaction measures by comparing single-item measures to the Satisfaction with Life Scale (SWLS)-a more psychometrically established measure. Two large samples from Washington (N = 13,064) and Oregon (N = 2,277) recruited by the Behavioral Risk Factor Surveillance System and a representative German sample (N = 1,312) recruited by the Germany Socio-Economic Panel were included in the present analyses. Single-item life satisfaction measures and the SWLS were correlated with theoretically relevant variables, such as demographics, subjective health, domain satisfaction, and affect. The correlations between the two life satisfaction measures and these variables were examined to assess the construct validity of single-item life satisfaction measures. Consistent across three samples, single-item life satisfaction measures demonstrated substantial degree of criterion validity with the SWLS (zero-order r = 0.62-0.64; disattenuated r = 0.78-0.80). Patterns of statistical significance for correlations with theoretically relevant variables were the same across single-item measures and the SWLS. Single-item measures did not produce systematically different correlations compared to the SWLS (average difference = 0.001-0.005). The average absolute difference in the magnitudes of the correlations produced by single-item measures and the SWLS was very small (average absolute difference = 0.015-0.042). Single-item life satisfaction measures performed very similarly compared to the multiple-item SWLS. Social scientists would get virtually identical answer to substantive questions regardless of which measure they use.

  16. Tank 241-AX-104 upper vadose zone cone penetrometer demonstration sampling and analysis plan

    International Nuclear Information System (INIS)

    FIELD, J.G.

    1999-01-01

    This sampling and analysis plan (SAP) is the primary document describing field and laboratory activities and requirements for the tank 241-AX-104 upper vadose zone cone penetrometer (CP) demonstration. It is written in accordance with Hanford Tank Initiative Tank 241-AX-104 Upper Vadose Zone Demonstration Data Quality Objective (Banning 1999). This technology demonstration, to be conducted at tank 241-AX-104, is being performed by the Hanford Tanks Initiative (HTI) Project as a part of Tank Waste Remediation System (TWRS) Retrieval Program (EM-30) and the Office of Science and Technology (EM-50) Tanks Focus Area. Sample results obtained as part of this demonstration will provide additional information for subsequent revisions to the Retrieval Performance Evaluation (RPE) report (Jacobs 1998). The RPE Report is the result of an evaluation of a single tank farm (AX Tank Farm) used as the basis for demonstrating a methodology for developing the data and analyses necessary to support making tank waste retrieval decisions within the context of tank farm closure requirements. The RPE includes a study of vadose zone contaminant transport mechanisms, including analysis of projected tank leak characteristics, hydrogeologic characteristics of tank farm soils, and the observed distribution of contaminants in the vadose zone in the tank farms. With limited characterization information available, large uncertainties exist as to the nature and extent of contaminants that may exist in the upper vadose zone in the AX Tank Farm. Traditionally, data has been collected from soils in the vadose zone through the installation of boreholes and wells. Soil samples are collected as the bore hole is advanced and samples are screened on site and/or sent to a laboratory for analysis. Some in-situ geophysical methods of contaminant analysis can be used to evaluate radionuclide levels in the soils adjacent to an existing borehole. However, geophysical methods require compensation for well

  17. A bench-top K X-ray fluorescence system for quantitative measurement of gold nanoparticles for biological sample diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Ricketts, K., E-mail: k.ricketts@ucl.ac.uk [Division of Surgery and Interventional Sciences, University College London, Royal Free Campus, Rowland Hill Street, London NW3 2PF (United Kingdom); Guazzoni, C.; Castoldi, A. [Dipartimento di Elettronica, Informazione e Bioingegneria Politecnico di Milano and INFN, Sezione di Milano P.za Leonardo da Vinci, 32-20133 Milano (Italy); Royle, G. [Department of Medical Physics and Bioengineering, University College London, Malet Place Engineering Building, Gower Street, London WC1E 6BT (United Kingdom)

    2016-04-21

    Gold nanoparticles can be targeted to biomarkers to give functional information on a range of tumour characteristics. X-ray fluorescence (XRF) techniques offer potential quantitative measurement of the distribution of such heavy metal nanoparticles. Biologists are developing 3D tissue engineered cellular models on the centimetre scale to optimise targeting techniques of nanoparticles to a range of tumour characteristics. Here we present a high energy bench-top K-X-ray fluorescence system designed for sensitivity to bulk measurement of gold nanoparticle concentration for intended use in such thick biological samples. Previous work has demonstrated use of a L-XRF system in measuring gold concentrations but being a low energy technique it is restricted to thin samples or superficial tumours. The presented system comprised a high purity germanium detector and filtered tungsten X-ray source, capable of quantitative measurement of gold nanoparticle concentration of thicker samples. The developed system achieved a measured detection limit of between 0.2 and 0.6 mgAu/ml, meeting specifications of biologists and being approximately one order of magnitude better than the detection limit of alternative K-XRF nanoparticle detection techniques. The scatter-corrected K-XRF signal of gold was linear with GNP concentrations down to the detection limit, thus demonstrating potential in GNP concentration quantification. The K-XRF system demonstrated between 5 and 9 times less sensitivity than a previous L-XRF bench-top system, due to a fundamental limitation of lower photoelectric interaction probabilities at higher K-edge energies. Importantly, the K-XRF technique is however less affected by overlying thickness, and so offers future potential in interrogating thick biological samples.

  18. Activation Measurements for Thermal Neutrons, U.S. Measurements of 36Cl in Mineral Samples from Hiroshima and Nagasaki; and Measurement of 63 Ni in Copper Samples From Hiroshima by Accelerator Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tore Straume; Alfredo A. Marchetti; Stephen D. Egbert; James A. Roberts; Ping Men; Shoichiro Fujita; Kiyoshi Shizuma; Masaharu Hoshi; G. Rugel; W. Ruhm; G. Korschinek; J. E. McAninch; K. L. Carroll; T. Faestermann; K. Knie; R. E. Martinelli; A. Wallner; C. Wallner

    2005-01-14

    The present paper presents the {sup 36}Cl measurement effort in the US. A large number of {sup 36}Cl measurements have been made in both granite and concrete samples obtained from various locations and distances in Hiroshima and Nagasaki. These measurements employed accelerator mass spectrometry (AMS) to quantify the number of atoms of {sup 36}Cl per atom of total Cl in the sample. Results from these measurements are presented here and discussed in the context of the DS02 dosimetry reevaluation effort for Hiroshima and Nagasaki atomic-bomb survivors. The production of {sup 36}Cl by bomb neutrons in mineral samples from Hiroshima and Nagasaki was primarily via the reaction {sup 35}Cl(n,{gamma}){sup 36}Cl. This reaction has a substantial thermal neutron cross-section (43.6 b at 0.025 eV) and the product has a long half-life (301,000 y). hence, it is well suited for neutron-activation detection in Hiroshima and Nagasaki using AMS more than 50 years after the bombings. A less important reaction for bomb neutrons, {sup 39}K(n,{alpha}){sup 36}Cl, typically produces less than 10% of the {sup 36}Cl in mineral samples such as granite and concrete, which contain {approx} 2% potassium. In 1988, only a year after the publication of the DS86 final report (Roesch 1987), it was demonstrated experimentally that {sup 36}Cl measured using AMS should be able to detect the thermal neutron fluences at the large distances most relevant to the A-bomb survivor dosimetry. Subsequent measurements in mineral samples from both Hiroshima and Nagasaki validated the experimental findings. The potential utility of {sup 36}Cl as a thermal neutron detector in Hiroshima was first presented by Haberstock et al. who employed the Munich AMS facility to measure {sup 36}Cl/Cl ratios in a gravestone from near the hypocenter. That work subsequently resulted in an expanded {sup 36}Cl effort in Germany that paralleled the US work. More recently, there have also been {sup 36}Cl measurements made by a Japanese

  19. Final report of the environmental measurement-while-drilling-gamma ray spectrometer system technology demonstration at the Savannah River Site F-Area Retention Basin

    Energy Technology Data Exchange (ETDEWEB)

    Lockwood, G.J.; Normann, R.A.; Williams, C.V.

    1997-08-01

    The environmental measurement-while-drilling-gamma ray spectrometer (EMWD-GRS) system represents an innovative blend of new and existing technology that provides real-time environmental and drill bit data during drilling operations. The EMWD-GRS technology was demonstrated at Savannah River Site F-Area Retention Basin. The EMWD-GRS technology demonstration consisted of continuously monitoring for gamma-radiation-producing contamination while drilling two horizontal boreholes below the backfilled retention basin. These boreholes passed near previously sampled vertical borehole locations where concentrations of contaminant levels of cesium had been measured. Contaminant levels continuously recorded by the EMWD-GRs system during drilling are compared to contaminant levels previously determined through quantitative laboratory analysis of soil samples.

  20. Final report of the environmental measurement-while-drilling-gamma ray spectrometer system technology demonstration at the Savannah River Site F-Area Retention Basin

    International Nuclear Information System (INIS)

    Lockwood, G.J.; Normann, R.A.; Williams, C.V.

    1997-08-01

    The environmental measurement-while-drilling-gamma ray spectrometer (EMWD-GRS) system represents an innovative blend of new and existing technology that provides real-time environmental and drill bit data during drilling operations. The EMWD-GRS technology was demonstrated at Savannah River Site F-Area Retention Basin. The EMWD-GRS technology demonstration consisted of continuously monitoring for gamma-radiation-producing contamination while drilling two horizontal boreholes below the backfilled retention basin. These boreholes passed near previously sampled vertical borehole locations where concentrations of contaminant levels of cesium had been measured. Contaminant levels continuously recorded by the EMWD-GRs system during drilling are compared to contaminant levels previously determined through quantitative laboratory analysis of soil samples

  1. Impact of shrinking measurement error budgets on qualification metrology sampling and cost

    Science.gov (United States)

    Sendelbach, Matthew; Sarig, Niv; Wakamoto, Koichi; Kim, Hyang Kyun (Helen); Isbester, Paul; Asano, Masafumi; Matsuki, Kazuto; Vaid, Alok; Osorio, Carmen; Archie, Chas

    2014-04-01

    When designing an experiment to assess the accuracy of a tool as compared to a reference tool, semiconductor metrologists are often confronted with the situation that they must decide on the sampling strategy before the measurements begin. This decision is usually based largely on the previous experience of the metrologist and the available resources, and not on the statistics that are needed to achieve acceptable confidence limits on the final result. This paper shows a solution to this problem, called inverse TMU analysis, by presenting statistically-based equations that allow the user to estimate the needed sampling after providing appropriate inputs, allowing him to make important "risk vs. reward" sampling, cost, and equipment decisions. Application examples using experimental data from scatterometry and critical dimension scanning electron microscope (CD-SEM) tools are used first to demonstrate how the inverse TMU analysis methodology can be used to make intelligent sampling decisions before the start of the experiment, and then to reveal why low sampling can lead to unstable and misleading results. A model is developed that can help an experimenter minimize the costs associated both with increased sampling and with making wrong decisions caused by insufficient sampling. A second cost model is described that reveals the inadequacy of current TEM (Transmission Electron Microscopy) sampling practices and the enormous costs associated with TEM sampling that is needed to provide reasonable levels of certainty in the result. These high costs reach into the tens of millions of dollars for TEM reference metrology as the measurement error budgets reach angstrom levels. The paper concludes with strategies on how to manage and mitigate these costs.

  2. Methods for Sampling and Measurement of Compressed Air Contaminants

    Energy Technology Data Exchange (ETDEWEB)

    Stroem, L

    1976-10-15

    In order to improve the technique for measuring oil and water entrained in a compressed air stream, a laboratory study has been made of some methods for sampling and measurement. For this purpose water or oil as artificial contaminants were injected in thin streams into a test loop, carrying dry compressed air. Sampling was performed in a vertical run, down-stream of the injection point. Wall attached liquid, coarse droplet flow, and fine droplet flow were sampled separately. The results were compared with two-phase flow theory and direct observation of liquid behaviour. In a study of sample transport through narrow tubes, it was observed that, below a certain liquid loading, the sample did not move, the liquid remaining stationary on the tubing wall. The basic analysis of the collected samples was made by gravimetric methods. Adsorption tubes were used with success to measure water vapour. A humidity meter with a sensor of the aluminium oxide type was found to be unreliable. Oil could be measured selectively by a flame ionization detector, the sample being pretreated in an evaporation- condensation unit

  3. Methods for Sampling and Measurement of Compressed Air Contaminants

    International Nuclear Information System (INIS)

    Stroem, L.

    1976-10-01

    In order to improve the technique for measuring oil and water entrained in a compressed air stream, a laboratory study has been made of some methods for sampling and measurement. For this purpose water or oil as artificial contaminants were injected in thin streams into a test loop, carrying dry compressed air. Sampling was performed in a vertical run, down-stream of the injection point. Wall attached liquid, coarse droplet flow, and fine droplet flow were sampled separately. The results were compared with two-phase flow theory and direct observation of liquid behaviour. In a study of sample transport through narrow tubes, it was observed that, below a certain liquid loading, the sample did not move, the liquid remaining stationary on the tubing wall. The basic analysis of the collected samples was made by gravimetric methods. Adsorption tubes were used with success to measure water vapour. A humidity meter with a sensor of the aluminium oxide type was found to be unreliable. Oil could be measured selectively by a flame ionization detector, the sample being pretreated in an evaporation- condensation unit

  4. High-temperature ultrasonic measurements applied to directly heated samples

    International Nuclear Information System (INIS)

    Moore, R.I.; Taylor, R.E.

    1984-01-01

    High-temperature ultrasonic measurements of Young's modulus were made of graphite samples heated directly. The samples were cylindrical rods of the same geometry as that used in the multiproperty apparatus for simultaneous/consecutive measurements of a number of thermophysical properties to high temperatures. The samples were resonated in simple longitudinal vibration modes. Measurements were performed up to 2000 K. Incorporation of ultrasonic measurements of Young's modulus in the capabilities of the multiproperty apparatus is valuable because (i) ultrasonic measurements can be related to normal destructive measurements of this property; (ii) they can be used for screening materials or acceptance testing of specimens; (iii) they can be used to increase the understanding of thermophysical properties and property correlations. (author)

  5. Radon measurement in Malaysia water samples

    International Nuclear Information System (INIS)

    Ibrahim, A.B.; Rosli Mahat; Yusof Md Amin

    1995-01-01

    This paper reported the results of the measurement of radon in local water. The water samples collected were rainwater, river water, seawater, well water or ground water at area of State of Selangor and Kuala Lumpur. The samples were collected in scintillation cell ZnS(Ag) through Radon Degassing Unit RDU 200. Alpha activity was counted with scintillation counters RD 200 at energy 5.5 MeV. (author)

  6. Conservative Sample Size Determination for Repeated Measures Analysis of Covariance.

    Science.gov (United States)

    Morgan, Timothy M; Case, L Douglas

    2013-07-05

    In the design of a randomized clinical trial with one pre and multiple post randomized assessments of the outcome variable, one needs to account for the repeated measures in determining the appropriate sample size. Unfortunately, one seldom has a good estimate of the variance of the outcome measure, let alone the correlations among the measurements over time. We show how sample sizes can be calculated by making conservative assumptions regarding the correlations for a variety of covariance structures. The most conservative choice for the correlation depends on the covariance structure and the number of repeated measures. In the absence of good estimates of the correlations, the sample size is often based on a two-sample t-test, making the 'ultra' conservative and unrealistic assumption that there are zero correlations between the baseline and follow-up measures while at the same time assuming there are perfect correlations between the follow-up measures. Compared to the case of taking a single measurement, substantial savings in sample size can be realized by accounting for the repeated measures, even with very conservative assumptions regarding the parameters of the assumed correlation matrix. Assuming compound symmetry, the sample size from the two-sample t-test calculation can be reduced at least 44%, 56%, and 61% for repeated measures analysis of covariance by taking 2, 3, and 4 follow-up measures, respectively. The results offer a rational basis for determining a fairly conservative, yet efficient, sample size for clinical trials with repeated measures and a baseline value.

  7. Assessing the Validity of Single-item Life Satisfaction Measures: Results from Three Large Samples

    Science.gov (United States)

    Cheung, Felix; Lucas, Richard E.

    2014-01-01

    Purpose The present paper assessed the validity of single-item life satisfaction measures by comparing single-item measures to the Satisfaction with Life Scale (SWLS) - a more psychometrically established measure. Methods Two large samples from Washington (N=13,064) and Oregon (N=2,277) recruited by the Behavioral Risk Factor Surveillance System (BRFSS) and a representative German sample (N=1,312) recruited by the Germany Socio-Economic Panel (GSOEP) were included in the present analyses. Single-item life satisfaction measures and the SWLS were correlated with theoretically relevant variables, such as demographics, subjective health, domain satisfaction, and affect. The correlations between the two life satisfaction measures and these variables were examined to assess the construct validity of single-item life satisfaction measures. Results Consistent across three samples, single-item life satisfaction measures demonstrated substantial degree of criterion validity with the SWLS (zero-order r = 0.62 – 0.64; disattenuated r = 0.78 – 0.80). Patterns of statistical significance for correlations with theoretically relevant variables were the same across single-item measures and the SWLS. Single-item measures did not produce systematically different correlations compared to the SWLS (average difference = 0.001 – 0.005). The average absolute difference in the magnitudes of the correlations produced by single-item measures and the SWLS were very small (average absolute difference = 0.015 −0.042). Conclusions Single-item life satisfaction measures performed very similarly compared to the multiple-item SWLS. Social scientists would get virtually identical answer to substantive questions regardless of which measure they use. PMID:24890827

  8. Rotor blade boundary layer measurement hardware feasibility demonstration

    Science.gov (United States)

    Clark, D. R.; Lawton, T. D.

    1972-01-01

    A traverse mechanism which allows the measurement of the three dimensional boundary layers on a helicopter rotor blade has been built and tested on a full scale rotor to full scale conditions producing centrifugal accelerations in excess of 400 g and Mach numbers of 0.6 and above. Boundary layer velocity profiles have been measured over a range of rotor speeds and blade collective pitch angles. A pressure scanning switch and transducer were also tested on the full scale rotor and found to be insensitive to centrifugal effects within the normal main rotor operating range. The demonstration of the capability to measure boundary layer behavior on helicopter rotor blades represents the first step toward obtaining, in the rotating system, data of a quality comparable to that already existing for flows in the fixed system.

  9. Results of tritium measurement in environmental samples and drainage

    International Nuclear Information System (INIS)

    Koike, Ryoji; Hirai, Yasuo

    1983-01-01

    In Ibaraki prefecture, the tritium concentration in the drainage from the nuclear facilities has been measured since 1974. Then, with the start of operation of the fuel reprocessing plant in 1977, the tritium concentration in environmental samples was to be measured also in order to examine the effect of the drainage on the environment. The results of the tritium measurement in Ibaraki prefecture up to about 1980 are described: sampling points, sampling and measuring methods, the tritium concentration in the drainage, air, inland water and seawater, respectively. The drainages have been taken from Japan Atomic Power Company, Japan Atomic Energy Research Institute, and Power Reactor and Nuclear Fuel Development Corporation (with the fuel reprocessing plant). The samples of air, inland water and seawater have been taken in the areas concerned. The tritium concentration was measured by a low-background liquid scintillation counter. The measured values in the environment have been generally at low level, not different from other areas. (Mori, K.)

  10. Measurements of astrophysical reaction rates for radioactive samples

    International Nuclear Information System (INIS)

    Koehler, P.E.; O'Brien, H.A.; Bowman, C.D.

    1987-01-01

    Reaction rates for both big-bang and stellar nucleosynthesis can be obtained from the measurement of (n,p) and (n,γ) cross sections for radioactive nuclei. In the past, large backgrounds associated with the sample activity limited these types of measurements to radioisotopes with very long half lives. The advent of the low-energy, high-intensity neutron source at the Los Alamos Neutron Scattering CEnter (LANSCE) has greatly increased the number of nuclei which can be studied. Results of (n,p) measurements on samples with half lives as short as fifty-three days will be given. The astrophysics to be learned from these data will be discussed. Additional difficulties are encountered when making (n,γ) rather than (n,p) measurements. However, with a properly designed detector, and with the high peak neutron intensities now available, (n,γ) measurements can be made for nuclei with half lives as short as several weeks. Progress on the Los Alamos (n,γ) cross-section measurement program for radioactive samples will be discussed. 25 refs., 3 figs., 1 tab

  11. Fault Sample Generation for Virtual Testability Demonstration Test Subject to Minimal Maintenance and Scheduled Replacement

    Directory of Open Access Journals (Sweden)

    Yong Zhang

    2015-01-01

    Full Text Available Virtual testability demonstration test brings new requirements to the fault sample generation. First, fault occurrence process is described by stochastic process theory. It is discussed that fault occurrence process subject to minimal repair is nonhomogeneous Poisson process (NHPP. Second, the interarrival time distribution function of the next fault event is proposed and three typical kinds of parameterized NHPP are discussed. Third, the procedure of fault sample generation is put forward with the assumptions of minimal maintenance and scheduled replacement. The fault modes and their occurrence time subject to specified conditions and time period can be obtained. Finally, an antenna driving subsystem in automatic pointing and tracking platform is taken as a case to illustrate the proposed method. Results indicate that both the size and structure of the fault samples generated by the proposed method are reasonable and effective. The proposed method can be applied to virtual testability demonstration test well.

  12. Decontamination of the extraction sample aisle at the West Valley Demonstration Project

    International Nuclear Information System (INIS)

    Vance, R.F.

    1986-09-01

    This report describes the decontamination and decommissioning (D and D) of the Extraction Sample Aisle (XSA) at the West Valley Demonstration Project. The XSA is one of several areas in the former reprocessing plant required for use in support of the solidification of high-level waste. The XSA contained three glove boxes which housed sample stations. It became radioactively contaminated during fuel reprocessing from 1966 to 1972. This report describes the work performed to accomplish the D and D objectives of removing existing piping and equipment and of reducing radiation and contamination levels, to As-Low-As-Reasonably-Achievable (ALARA) levels for the installation of new equipment. Also reported are pre- and post-radiological conditions, personnel exposure, radioactive waste volume collected, cost and schedule data, and lessons learned

  13. 36Cl measurements of Hiroshima concrete samples

    International Nuclear Information System (INIS)

    Matsuhiro, T.; Nagashima, Y.; Seki, R.; Takahashi, T.

    2002-01-01

    The 36 Cl AMS studies are reported. A new steps of procedure of a sample preparation is developed and a tremendous reduction of sulphur background has been achieved. The 36 Cl contents of two atomic bombed concrete samples, old Hiroshima Bank one and Gokoku Shrine one, have been measured as a function of 36 Cl to Cl ratio by the Tsukuba AMS system. The 36 Cl to Cl ratio of the old Hiroshima Bank sample shows very nice agreement with the result of γ measurement of 152 Eu. Otherwise, the ratio is about 20% smaller than an estimation by the DS86 dosimetry system. A result of the Gokoku Shrine sample is also smaller than a depth profile estimation by the same DS86. It might be clear that the DS86 has a tendency of overestimation. It seems that a calculation method and/or the parameters used in the calculation are requested to be improved. (author)

  14. Conditional-sampling spectrograph detection system for fluorescence measurements of individual airborne biological particles

    Science.gov (United States)

    Nachman, Paul; Pinnick, R. G.; Hill, Steven C.; Chen, Gang; Chang, Richard K.; Mayo, Michael W.; Fernandez, Gilbert L.

    1996-03-01

    We report the design and operation of a prototype conditional-sampling spectrograph detection system that can record the fluorescence spectra of individual, micrometer-sized aerosols as they traverse an intense 488-nm intracavity laser beam. The instrument's image-intensified CCD detector is gated by elastic scattering or by undispersed fluorescence from particles that enter the spectrograph's field of view. It records spectra only from particles with preselected scattering-fluorescence levels (a fiber-optic-photomultiplier subsystem provides the gating signal). This conditional-sampling procedure reduces data-handling rates and increases the signal-to-noise ratio by restricting the system's exposures to brief periods when aerosols traverse the beam. We demonstrate these advantages by reliably capturing spectra from individual fluorescent microspheres dispersed in an airstream. The conditional-sampling procedure also permits some discrimination among different types of particles, so that spectra may be recorded from the few interesting particles present in a cloud of background aerosol. We demonstrate such discrimination by measuring spectra from selected fluorescent microspheres in a mixture of two types of microspheres, and from bacterial spores in a mixture of spores and nonfluorescent kaolin particles.

  15. Statistical sampling for holdup measurement

    International Nuclear Information System (INIS)

    Picard, R.R.; Pillay, K.K.S.

    1986-01-01

    Nuclear materials holdup is a serious problem in many operating facilities. Estimating amounts of holdup is important for materials accounting and, sometimes, for process safety. Clearly, measuring holdup in all pieces of equipment is not a viable option in terms of time, money, and radiation exposure to personnel. Furthermore, 100% measurement is not only impractical but unnecessary for developing estimated values. Principles of statistical sampling are valuable in the design of cost effective holdup monitoring plans and in qualifying uncertainties in holdup estimates. The purpose of this paper is to describe those principles and to illustrate their use

  16. Quantum supremacy in constant-time measurement-based computation: A unified architecture for sampling and verification

    Science.gov (United States)

    Miller, Jacob; Sanders, Stephen; Miyake, Akimasa

    2017-12-01

    While quantum speed-up in solving certain decision problems by a fault-tolerant universal quantum computer has been promised, a timely research interest includes how far one can reduce the resource requirement to demonstrate a provable advantage in quantum devices without demanding quantum error correction, which is crucial for prolonging the coherence time of qubits. We propose a model device made of locally interacting multiple qubits, designed such that simultaneous single-qubit measurements on it can output probability distributions whose average-case sampling is classically intractable, under similar assumptions as the sampling of noninteracting bosons and instantaneous quantum circuits. Notably, in contrast to these previous unitary-based realizations, our measurement-based implementation has two distinctive features. (i) Our implementation involves no adaptation of measurement bases, leading output probability distributions to be generated in constant time, independent of the system size. Thus, it could be implemented in principle without quantum error correction. (ii) Verifying the classical intractability of our sampling is done by changing the Pauli measurement bases only at certain output qubits. Our usage of random commuting quantum circuits in place of computationally universal circuits allows a unique unification of sampling and verification, so they require the same physical resource requirements in contrast to the more demanding verification protocols seen elsewhere in the literature.

  17. MD1405: Demonstration of forced dynamic aperture measurements at injection

    CERN Document Server

    Carlier, Felix Simon; Persson, Tobias Hakan Bjorn; Tomas Garcia, Rogelio; CERN. Geneva. ATS Department

    2017-01-01

    Accurate measurements of dynamic aperture become more important for the LHC as it advances into increasingly nonlinear regimes of operations, as well as for the High Luminosity LHC where machine nonlinearities will have a significantly larger impact. Direct dynamic aperture measurements at top energy in the LHC are challenging, and conventional single kick methods are not viable. Dynamic aperture measurements under forced oscillation of AC dipoles have been proposed as s possible alternative observable. A first demonstration of forced DA measurements at injections energy is presented.

  18. Integrated sampling and analysis plan for samples measuring >10 mrem/hour

    International Nuclear Information System (INIS)

    Haller, C.S.

    1992-03-01

    This integrated sampling and analysis plan was prepared to assist in planning and scheduling of Hanford Site sampling and analytical activities for all waste characterization samples that measure greater than 10 mrem/hour. This report also satisfies the requirements of the renegotiated Interim Milestone M-10-05 of the Hanford Federal Facility Agreement and Consent Order (the Tri-Party Agreement). For purposes of comparing the various analytical needs with the Hanford Site laboratory capabilities, the analytical requirements of the various programs were normalized by converting required laboratory effort for each type of sample to a common unit of work, the standard analytical equivalency unit (AEU). The AEU approximates the amount of laboratory resources required to perform an extensive suite of analyses on five core segments individually plus one additional suite of analyses on a composite sample derived from a mixture of the five core segments and prepare a validated RCRA-type data package

  19. Measuring radioactive half-lives via statistical sampling in practice

    Science.gov (United States)

    Lorusso, G.; Collins, S. M.; Jagan, K.; Hitt, G. W.; Sadek, A. M.; Aitken-Smith, P. M.; Bridi, D.; Keightley, J. D.

    2017-10-01

    The statistical sampling method for the measurement of radioactive decay half-lives exhibits intriguing features such as that the half-life is approximately the median of a distribution closely resembling a Cauchy distribution. Whilst initial theoretical considerations suggested that in certain cases the method could have significant advantages, accurate measurements by statistical sampling have proven difficult, for they require an exercise in non-standard statistical analysis. As a consequence, no half-life measurement using this method has yet been reported and no comparison with traditional methods has ever been made. We used a Monte Carlo approach to address these analysis difficulties, and present the first experimental measurement of a radioisotope half-life (211Pb) by statistical sampling in good agreement with the literature recommended value. Our work also focused on the comparison between statistical sampling and exponential regression analysis, and concluded that exponential regression achieves generally the highest accuracy.

  20. Bulk sample self-attenuation correction by transmission measurement

    International Nuclear Information System (INIS)

    Parker, J.L.; Reilly, T.D.

    1976-01-01

    Various methods used in either finding or avoiding the attenuation correction in the passive γ-ray assay of bulk samples are reviewed. Detailed consideration is given to the transmission method, which involves experimental determination of the sample linear attenuation coefficient by measuring the transmission through the sample of a beam of gamma rays from an external source. The method was applied to box- and cylindrically-shaped samples

  1. Design of a radioactive gas sampling system for NESHAP compliance measurements of 41Ar

    International Nuclear Information System (INIS)

    Newton, G.J.; McDonald, M.J.; Ghanbari, F.; Hoover, M.D.; Barr, E.B.

    1994-01-01

    United States Department of Energy facilities are required to comply with the U.S. Environmental Protection Agency, National Emission Standard for Hazardous Air Pollutants (NESHAP) 40 CFR, part 61, subpart H. Compliance generally requires confirmatory measurements of emitted radionuclides. Although a number of standard procedures exist for extractive sampling of particle-associated radionuclides, sampling approaches for radioactive gases are less defined. Real-time, flow-through sampling of radioactive gases can be done when concentrations are high compared to interferences from background radiation. Cold traps can be used to collect and concentrate condensible effluents in applications where cryogenic conditions can be established and maintained. Commercially available gas-sampling cylinders can be used to capture grab samples of contaminated air under ambient or compressed conditions, if suitable sampling and control hardware are added to the cylinders. The purpose of the current study was to develop an efficient and compact set of sampling and control hardware for use with commercially available gas-sampling cylinders, and to demonstrate its use in NESHAP compliance testing of 41 Ar at two experimental research reactors

  2. Integrating sphere based reflectance measurements for small-area semiconductor samples

    Science.gov (United States)

    Saylan, S.; Howells, C. T.; Dahlem, M. S.

    2018-05-01

    This article describes a method that enables reflectance spectroscopy of small semiconductor samples using an integrating sphere, without the use of additional optical elements. We employed an inexpensive sample holder to measure the reflectance of different samples through 2-, 3-, and 4.5-mm-diameter apertures and applied a mathematical formulation to remove the bias from the measured spectra caused by illumination of the holder. Using the proposed method, the reflectance of samples fabricated using expensive or rare materials and/or low-throughput processes can be measured. It can also be incorporated to infer the internal quantum efficiency of small-area, research-level solar cells. Moreover, small samples that reflect light at large angles and develop scattering may also be measured reliably, by virtue of an integrating sphere insensitive to directionalities.

  3. Sample-interpolation timing: an optimized technique for the digital measurement of time of flight for γ rays and neutrons at relatively low sampling rates

    International Nuclear Information System (INIS)

    Aspinall, M D; Joyce, M J; Mackin, R O; Jarrah, Z; Boston, A J; Nolan, P J; Peyton, A J; Hawkes, N P

    2009-01-01

    A unique, digital time pick-off method, known as sample-interpolation timing (SIT) is described. This method demonstrates the possibility of improved timing resolution for the digital measurement of time of flight compared with digital replica-analogue time pick-off methods for signals sampled at relatively low rates. Three analogue timing methods have been replicated in the digital domain (leading-edge, crossover and constant-fraction timing) for pulse data sampled at 8 GSa s −1 . Events arising from the 7 Li(p, n) 7 Be reaction have been detected with an EJ-301 organic liquid scintillator and recorded with a fast digital sampling oscilloscope. Sample-interpolation timing was developed solely for the digital domain and thus performs more efficiently on digital signals compared with analogue time pick-off methods replicated digitally, especially for fast signals that are sampled at rates that current affordable and portable devices can achieve. Sample interpolation can be applied to any analogue timing method replicated digitally and thus also has the potential to exploit the generic capabilities of analogue techniques with the benefits of operating in the digital domain. A threshold in sampling rate with respect to the signal pulse width is observed beyond which further improvements in timing resolution are not attained. This advance is relevant to many applications in which time-of-flight measurement is essential

  4. Performance demonstration program plan for analysis of simulated headspace gases

    International Nuclear Information System (INIS)

    1995-06-01

    The Performance Demonstration Program (PDP) for analysis of headspace gases will consist of regular distribution and analyses of test standards to evaluate the capability for analyzing VOCs, hydrogen, and methane in the headspace of transuranic (TRU) waste throughout the Department of Energy (DOE) complex. Each distribution is termed a PDP cycle. These evaluation cycles will provide an objective measure of the reliability of measurements performed for TRU waste characterization. Laboratory performance will be demonstrated by the successful analysis of blind audit samples of simulated TRU waste drum headspace gases according to the criteria set within the text of this Program Plan. Blind audit samples (hereinafter referred to as PDP samples) will be used as an independent means to assess laboratory performance regarding compliance with the QAPP QAOs. The concentration of analytes in the PDP samples will encompass the range of concentrations anticipated in actual waste characterization gas samples. Analyses which are required by the WIPP to demonstrate compliance with various regulatory requirements and which are included in the PDP must be performed by laboratories which have demonstrated acceptable performance in the PDP

  5. Performance Demonstration Program Plan for Analysis of Simulated Headspace Gases

    International Nuclear Information System (INIS)

    2006-01-01

    The Performance Demonstration Program (PDP) for headspace gases distributes sample gases of volatile organic compounds (VOCs) for analysis. Participating measurement facilities (i.e., fixed laboratories, mobile analysis systems, and on-line analytical systems) are located across the United States. Each sample distribution is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements performed for transuranic (TRU) waste characterization. The primary documents governing the conduct of the PDP are the Quality Assurance Program Document (QAPD) (DOE/CBFO-94-1012) and the Waste Isolation Pilot Plant (WIPP) Waste Analysis Plan (WAP) contained in the Hazardous Waste Facility Permit (NM4890139088-TSDF) issued by the New Mexico Environment Department (NMED). The WAP requires participation in the PDP; the PDP must comply with the QAPD and the WAP. This plan implements the general requirements of the QAPD and the applicable requirements of the WAP for the Headspace Gas (HSG) PDP. Participating measurement facilities analyze blind audit samples of simulated TRU waste package headspace gases according to the criteria set by this PDP Plan. Blind audit samples (hereafter referred to as PDP samples) are used as an independent means to assess each measurement facility's compliance with the WAP quality assurance objectives (QAOs). To the extent possible, the concentrations of VOC analytes in the PDP samples encompass the range of concentrations anticipated in actual TRU waste package headspace gas samples. Analyses of headspace gases are required by the WIPP to demonstrate compliance with regulatory requirements. These analyses must be performed by measurement facilities that have demonstrated acceptable performance in this PDP. These analyses are referred to as WIPP analyses and the TRU waste package headspace gas samples on which they are performed are referred to as WIPP samples in this document. Participating measurement

  6. Performance Demonstration Program Plan for Analysis of Simulated Headspace Gases

    International Nuclear Information System (INIS)

    2007-01-01

    The Performance Demonstration Program (PDP) for headspace gases distributes blind audit samples in a gas matrix for analysis of volatile organic compounds (VOCs). Participating measurement facilities (i.e., fixed laboratories, mobile analysis systems, and on-line analytical systems) are located across the United States. Each sample distribution is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements performed for transuranic (TRU) waste characterization. The primary documents governing the conduct of the PDP are the Quality Assurance Program Document (QAPD) (DOE/CBFO-94-1012) and the Waste Isolation Pilot Plant (WIPP) Waste Analysis Plan (WAP) contained in the Hazardous Waste Facility Permit (NM4890139088-TSDF) issued by the New Mexico Environment Department (NMED). The WAP requires participation in the PDP; the PDP must comply with the QAPD and the WAP. This plan implements the general requirements of the QAPD and the applicable requirements of the WAP for the Headspace Gas (HSG) PDP. Participating measurement facilities analyze blind audit samples of simulated TRU waste package headspace gases according to the criteria set by this PDP Plan. Blind audit samples (hereafter referred to as PDP samples) are used as an independent means to assess each measurement facility's compliance with the WAP quality assurance objectives (QAOs). To the extent possible, the concentrations of VOC analytes in the PDP samples encompass the range of concentrations anticipated in actual TRU waste package headspace gas samples. Analyses of headspace gases are required by the WIPP to demonstrate compliance with regulatory requirements. These analyses must be performed by measurement facilities that have demonstrated acceptable performance in this PDP. These analyses are referred to as WIPP analyses and the TRU waste package headspace gas samples on which they are performed are referred to as WIPP samples in this document

  7. Sampling Criterion for EMC Near Field Measurements

    DEFF Research Database (Denmark)

    Franek, Ondrej; Sørensen, Morten; Ebert, Hans

    2012-01-01

    An alternative, quasi-empirical sampling criterion for EMC near field measurements intended for close coupling investigations is proposed. The criterion is based on maximum error caused by sub-optimal sampling of near fields in the vicinity of an elementary dipole, which is suggested as a worst......-case representative of a signal trace on a typical printed circuit board. It has been found that the sampling density derived in this way is in fact very similar to that given by the antenna near field sampling theorem, if an error less than 1 dB is required. The principal advantage of the proposed formulation is its...

  8. Measurement of trace elements in liver biopsy samples from cattle

    NARCIS (Netherlands)

    Ouweltjes, W.; Zeeuw, de A.C.; Moen, A.; Counotte, G.H.M.

    2007-01-01

    Serum, plasma, or urine samples are usually used for the measurement of the trace elements copper, zinc, iron, selenium, because these samples are easy to obtain; however, these samples are not always appropriate. For example, it is not possible to measure molybdenum, the major antagonist of copper,

  9. Stochastic bounded consensus tracking of leader—follower multi-agent systems with measurement noises and sampled-data

    International Nuclear Information System (INIS)

    Wu Zhi-Hai; Peng Li; Xie Lin-Bo; Wen Ji-Wei

    2012-01-01

    This paper is concerned with the stochastic bounded consensus tracking problems of leader—follower multi-agent systems, where the control input of an agent can only use the information measured at the sampling instants from its neighbours or the virtual leader with a time-varying reference state, and the measurements are corrupted by random noises. The probability limit theory and the algebra graph theory are employed to derive the necessary and sufficient conditions guaranteeing the mean square bounded consensus tracking. It is shown that the maximum allowable upper boundary of the sampling period simultaneously depends on the constant feedback gains and the network topology. Furthermore, the effects of the sampling period on the tracking performance are analysed. It turns out that from the view point of the sampling period, there is a trade-off between the tracking speed and the static tracking error. Simulations are provided to demonstrate the effectiveness of the theoretical results. (interdisciplinary physics and related areas of science and technology)

  10. Measurement assurance program for LSC analyses of tritium samples

    International Nuclear Information System (INIS)

    Levi, G.D. Jr.; Clark, J.P.

    1997-01-01

    Liquid Scintillation Counting (LSC) for Tritium is done on 600 to 800 samples daily as part of a contamination control program at the Savannah River Site's Tritium Facilities. The tritium results from the LSCs are used: to release items as radiologically clean; to establish radiological control measures for workers; and to characterize waste. The following is a list of the sample matrices that are analyzed for tritium: filter paper smears, aqueous, oil, oily rags, ethylene glycol, ethyl alcohol, freon and mercury. Routine and special causes of variation in standards, counting equipment, environment, operators, counting times, samples, activity levels, etc. produce uncertainty in the LSC measurements. A comprehensive analytical process measurement assurance program such as JTIPMAP trademark has been implemented. The process measurement assurance program is being used to quantify and control many of the sources of variation and provide accurate estimates of the overall measurement uncertainty associated with the LSC measurements. The paper will describe LSC operations, process improvements, quality control and quality assurance programs along with future improvements associated with the implementation of the process measurement assurance program

  11. Demonstration of a longitudinal concentration gradient along scala tympani by sequential sampling of perilymph from the cochlear apex.

    Science.gov (United States)

    Mynatt, Robert; Hale, Shane A; Gill, Ruth M; Plontke, Stefan K; Salt, Alec N

    2006-06-01

    Local applications of drugs to the inner ear are increasingly being used to treat patients' inner ear disorders. Knowledge of the pharmacokinetics of drugs in the inner ear fluids is essential for a scientific basis for such treatments. When auditory function is of primary interest, the drug's kinetics in scala tympani (ST) must be established. Measurement of drug levels in ST is technically difficult because of the known contamination of perilymph samples taken from the basal cochlear turn with cerebrospinal fluid (CSF). Recently, we reported a technique in which perilymph was sampled from the cochlear apex to minimize the influence of CSF contamination (J. Neurosci. Methods, doi: 10.1016/j.jneumeth.2005.10.008 ). This technique has now been extended by taking smaller fluid samples sequentially from the cochlear apex, which can be used to quantify drug gradients along ST. The sampling and analysis methods were evaluated using an ionic marker, trimethylphenylammonium (TMPA), that was applied to the round window membrane. After loading perilymph with TMPA, 10 1-muL samples were taken from the cochlear apex. The TMPA content of the samples was consistent with the first sample containing perilymph from apical regions and the fourth or fifth sample containing perilymph from the basal turn. TMPA concentration decreased in subsequent samples, as they increasingly contained CSF that had passed through ST. Sample concentration curves were interpreted quantitatively by simulation of the experiment with a finite element model and by an automated curve-fitting method by which the apical-basal gradient was estimated. The study demonstrates that sequential apical sampling provides drug gradient data for ST perilymph while avoiding the major distortions of sample composition associated with basal turn sampling. The method can be used for any substance for which a sensitive assay is available and is therefore of high relevance for the development of preclinical and clinical

  12. Interval sampling methods and measurement error: a computer simulation.

    Science.gov (United States)

    Wirth, Oliver; Slaven, James; Taylor, Matthew A

    2014-01-01

    A simulation study was conducted to provide a more thorough account of measurement error associated with interval sampling methods. A computer program simulated the application of momentary time sampling, partial-interval recording, and whole-interval recording methods on target events randomly distributed across an observation period. The simulation yielded measures of error for multiple combinations of observation period, interval duration, event duration, and cumulative event duration. The simulations were conducted up to 100 times to yield measures of error variability. Although the present simulation confirmed some previously reported characteristics of interval sampling methods, it also revealed many new findings that pertain to each method's inherent strengths and weaknesses. The analysis and resulting error tables can help guide the selection of the most appropriate sampling method for observation-based behavioral assessments. © Society for the Experimental Analysis of Behavior.

  13. Mass thickness measurement of dual-sample by dual-energy X-rays

    International Nuclear Information System (INIS)

    Chen Mincong; Li Hongmei; Chen Ziyu; Shen Ji

    2008-01-01

    X-ray equivalent energy can be used to measure mass thicknesses of materials. Based on this, a method of mass thickness measurement of dual-sample was discussed. It was found that in the range of sample mass thickness under investigation, the equivalent mass attenuation coefficient of a component could be used to compute mass thicknesses of a dual-sample, with relative errors of less than 5%. Mass thickness measurement of a fish sample was performed, and the fish bone and flesh could be displayed separately and clearly by their own mass thicknesses. This indicates that the method is effective in mass thickness measurement of dual-sample of suitable thicknesses. (authors)

  14. Automated Sampling and Extraction of Krypton from Small Air Samples for Kr-85 Measurement Using Atom Trap Trace Analysis

    International Nuclear Information System (INIS)

    Hebel, S.; Hands, J.; Goering, F.; Kirchner, G.; Purtschert, R.

    2015-01-01

    Atom-Trap-Trace-Analysis (ATTA) provides the capability of measuring the Krypton-85 concentration in microlitre amounts of krypton extracted from air samples of about 1 litre. This sample size is sufficiently small to allow for a range of applications, including on-site spot sampling and continuous sampling over periods of several hours. All samples can be easily handled and transported to an off-site laboratory for ATTA measurement, or stored and analyzed on demand. Bayesian sampling methodologies can be applied by blending samples for bulk measurement and performing in-depth analysis as required. Prerequisite for measurement is the extraction of a pure krypton fraction from the sample. This paper introduces an extraction unit able to isolate the krypton in small ambient air samples with high speed, high efficiency and in a fully automated manner using a combination of cryogenic distillation and gas chromatography. Air samples are collected using an automated smart sampler developed in-house to achieve a constant sampling rate over adjustable time periods ranging from 5 minutes to 3 hours per sample. The smart sampler can be deployed in the field and operate on battery for one week to take up to 60 air samples. This high flexibility of sampling and the fast, robust sample preparation are a valuable tool for research and the application of Kr-85 measurements to novel Safeguards procedures. (author)

  15. Trace-element measurement in human blood samples

    International Nuclear Information System (INIS)

    Hamidian, M.R.; Ebrahimi-Fakhar, F.

    1992-01-01

    It is conceivable that some essential elements such as zinc, iron, calcium, copper, phosphorus, selenium, etc., have a major impact on biological and metabolical functions in the human body. The concentration of these elements is normally very minute and changes within a naturally set tolerance. The accurate measurement of these elements in biological samples, such as in blood, is one of the objectives of medical physics in diagnosis. There are many sophisticated methods to measure the accurate amount of each element in biological samples. The methods used in this project are a combination of proton-induced X-ray emission (PIXE) and neutron activation analysis (NAA). The PIXE and NAA are fast and reliable techniques for multielement analysis at the level of parts per million and less

  16. Considerations for sampling nuclear materials for SNM accounting measurements

    International Nuclear Information System (INIS)

    Brouns, R.J.; Roberts, F.P.; Upson, U.L.

    1978-01-01

    This report presents principles and guidelines for sampling nuclear materials to measure chemical and isotopic content of the material. Development of sampling plans and procedures that maintain the random and systematic errors of sampling within acceptable limits for SNM accounting purposes are emphasized

  17. Determination and optimization of spatial samples for distributed measurements.

    Energy Technology Data Exchange (ETDEWEB)

    Huo, Xiaoming (Georgia Institute of Technology, Atlanta, GA); Tran, Hy D.; Shilling, Katherine Meghan; Kim, Heeyong (Georgia Institute of Technology, Atlanta, GA)

    2010-10-01

    There are no accepted standards for determining how many measurements to take during part inspection or where to take them, or for assessing confidence in the evaluation of acceptance based on these measurements. The goal of this work was to develop a standard method for determining the number of measurements, together with the spatial distribution of measurements and the associated risks for false acceptance and false rejection. Two paths have been taken to create a standard method for selecting sampling points. A wavelet-based model has been developed to select measurement points and to determine confidence in the measurement after the points are taken. An adaptive sampling strategy has been studied to determine implementation feasibility on commercial measurement equipment. Results using both real and simulated data are presented for each of the paths.

  18. Environmental measurement-while-drilling-gamma ray spectrometer (EMWD-GRS) system technology demonstration plan for use at the Savannah River Site F-Area Retention Basin

    International Nuclear Information System (INIS)

    Williams, C.V.; Lockwood, G.J.; Normann, R.A.; Gruebel, R.D.

    1996-08-01

    The Environmental Measurement-While-Drilling-Gamma Ray Spectrometer (EMWD-GRS) system represents an innovative blend of new and existing technology that provides the capability of producing real-time environmental and drillbit data during drilling operations. This demonstration plan presents information on the EMWD-GRS technology, demonstration design, Cs-137 contamination at the Savannah River Site F-Area Retention Basin, responsibilities of demonstration participants, and the policies and procedures for the demonstration to be conducted at the Savannah River Site F-Area Retention Basin. The EMWD-GRS technology demonstration will consist of continuously monitoring for gamma-radiation contamination while drilling two horizontal boreholes below the backfilled retention basin. These boreholes will pass near previously sampled vertical borehole locations where concentrations of contaminant levels are known. Contaminant levels continuously recorded by the EMWD-GRS system during drilling will be compared to contaminant levels previously determined through quantitative laboratory analysis of soil samples

  19. Environmental measurement-while-drilling-gamma ray spectrometer (EMWD-GRS) system technology demonstration plan for use at the Savannah River Site F-Area Retention Basin

    Energy Technology Data Exchange (ETDEWEB)

    Williams, C.V.; Lockwood, G.J.; Normann, R.A. [Sandia National Labs., Albuquerque, NM (United States); Gruebel, R.D. [Tech Reps, Inc., Albuquerque, NM (United States)

    1996-08-01

    The Environmental Measurement-While-Drilling-Gamma Ray Spectrometer (EMWD-GRS) system represents an innovative blend of new and existing technology that provides the capability of producing real-time environmental and drillbit data during drilling operations. This demonstration plan presents information on the EMWD-GRS technology, demonstration design, Cs-137 contamination at the Savannah River Site F-Area Retention Basin, responsibilities of demonstration participants, and the policies and procedures for the demonstration to be conducted at the Savannah River Site F-Area Retention Basin. The EMWD-GRS technology demonstration will consist of continuously monitoring for gamma-radiation contamination while drilling two horizontal boreholes below the backfilled retention basin. These boreholes will pass near previously sampled vertical borehole locations where concentrations of contaminant levels are known. Contaminant levels continuously recorded by the EMWD-GRS system during drilling will be compared to contaminant levels previously determined through quantitative laboratory analysis of soil samples.

  20. Non-Contact Conductivity Measurement for Automated Sample Processing Systems

    Science.gov (United States)

    Beegle, Luther W.; Kirby, James P.

    2012-01-01

    A new method has been developed for monitoring and control of automated sample processing and preparation especially focusing on desalting of samples before analytical analysis (described in more detail in Automated Desalting Apparatus, (NPO-45428), NASA Tech Briefs, Vol. 34, No. 8 (August 2010), page 44). The use of non-contact conductivity probes, one at the inlet and one at the outlet of the solid phase sample preparation media, allows monitoring of the process, and acts as a trigger for the start of the next step in the sequence (see figure). At each step of the muti-step process, the system is flushed with low-conductivity water, which sets the system back to an overall low-conductivity state. This measurement then triggers the next stage of sample processing protocols, and greatly minimizes use of consumables. In the case of amino acid sample preparation for desalting, the conductivity measurement will define three key conditions for the sample preparation process. First, when the system is neutralized (low conductivity, by washing with excess de-ionized water); second, when the system is acidified, by washing with a strong acid (high conductivity); and third, when the system is at a basic condition of high pH (high conductivity). Taken together, this non-contact conductivity measurement for monitoring sample preparation will not only facilitate automation of the sample preparation and processing, but will also act as a way to optimize the operational time and use of consumables

  1. Assessing the precision of a time-sampling-based study among GPs: balancing sample size and measurement frequency.

    Science.gov (United States)

    van Hassel, Daniël; van der Velden, Lud; de Bakker, Dinny; van der Hoek, Lucas; Batenburg, Ronald

    2017-12-04

    Our research is based on a technique for time sampling, an innovative method for measuring the working hours of Dutch general practitioners (GPs), which was deployed in an earlier study. In this study, 1051 GPs were questioned about their activities in real time by sending them one SMS text message every 3 h during 1 week. The required sample size for this study is important for health workforce planners to know if they want to apply this method to target groups who are hard to reach or if fewer resources are available. In this time-sampling method, however, standard power analyses is not sufficient for calculating the required sample size as this accounts only for sample fluctuation and not for the fluctuation of measurements taken from every participant. We investigated the impact of the number of participants and frequency of measurements per participant upon the confidence intervals (CIs) for the hours worked per week. Statistical analyses of the time-use data we obtained from GPs were performed. Ninety-five percent CIs were calculated, using equations and simulation techniques, for various different numbers of GPs included in the dataset and for various frequencies of measurements per participant. Our results showed that the one-tailed CI, including sample and measurement fluctuation, decreased from 21 until 3 h between one and 50 GPs. As a result of the formulas to calculate CIs, the increase of the precision continued and was lower with the same additional number of GPs. Likewise, the analyses showed how the number of participants required decreased if more measurements per participant were taken. For example, one measurement per 3-h time slot during the week requires 300 GPs to achieve a CI of 1 h, while one measurement per hour requires 100 GPs to obtain the same result. The sample size needed for time-use research based on a time-sampling technique depends on the design and aim of the study. In this paper, we showed how the precision of the

  2. Variable screening and ranking using sampling-based sensitivity measures

    International Nuclear Information System (INIS)

    Wu, Y-T.; Mohanty, Sitakanta

    2006-01-01

    This paper presents a methodology for screening insignificant random variables and ranking significant important random variables using sensitivity measures including two cumulative distribution function (CDF)-based and two mean-response based measures. The methodology features (1) using random samples to compute sensitivities and (2) using acceptance limits, derived from the test-of-hypothesis, to classify significant and insignificant random variables. Because no approximation is needed in either the form of the performance functions or the type of continuous distribution functions representing input variables, the sampling-based approach can handle highly nonlinear functions with non-normal variables. The main characteristics and effectiveness of the sampling-based sensitivity measures are investigated using both simple and complex examples. Because the number of samples needed does not depend on the number of variables, the methodology appears to be particularly suitable for problems with large, complex models that have large numbers of random variables but relatively few numbers of significant random variables

  3. Tracer measured substrate turnover requires arterial sampling downstream of infusion site

    International Nuclear Information System (INIS)

    Stanley, W.C.; Neese, R.A.; Gertz, E.W.; Wisneski, J.A.; Morris, D.L.; Brooks, G.A.

    1986-01-01

    Measurement of metabolite turnover (Rt) with radioactive tracers is done by either infusing tracer venously and sampling specific activity (SA) arterially (V-A modes), or by infusing into the aorta and sampling venous blood (A-V mode). Using the Fick principle, the necessity for using the V-A mode can be demonstrated. If tracer is infused into the left ventricle, in a steady state the Rt is the product of arterial trace concentration, the cardiac output, and the tracer extraction ratio for the whole body. This is expressed as: Rt = Ca x Qx ((*Ca - *Cv)/*Ca) (Eq1) where C=trace concentration (μmol/ml), *C=tracer conc. (dpm/ml), a=arterial, v-=mixed venous, and Q=cardiac output (ml/min). Rearranging the equation: Rt = Qx(*Ca - *Cv)/SAa = F/SAa (Eq2) where SAa is *Ca/Ca, and Qx (*Ca-*Cv) equals the infusion rate (F). The authors compared Eqs1 and 2 (Rt = F/SAa) in 3 anesthetized dogs in which [1- 14 C] lactate was infused into the left ventricle, and blood was sampled arterially downstream from the infusion site and in the pulmonary artery. Eqs 1 and 2 gave similar results for Rt (45.9 vs. 43.9 μmol/kg min), while substituting SAv for SAa (A-V mode) into Eq 2 gave a higher Rt (53.6). When SAv (A-V mode) is used, the specific activity seen by the tissues (SAa) is not considered in the calculation of Rt. Therefore, only the V-A mode meets the requirements for tracer measured metabolite turnover

  4. Quantitative NMR measurements on core samples

    International Nuclear Information System (INIS)

    Olsen, Dan

    1997-01-01

    Within the frame of an EFP-95 project NMR methods for porosity determination in 2D, and for fluid saturation determination in 1D and 2D have been developed. The three methods have been developed and tested on cleaned core samples of chalk from the Danish North Sea. The main restriction for the use of the methods is the inherently short T2 relaxation constants of rock samples. Referring to measurements conducted at 200 MHz, the 2D porosity determination method is applicable to sample material with T2 relaxation constants down to 5 ms. The 1D fluid saturation determination method is applicable to sample material with T2 relaxation constants down to 3 ms, while the 2D fluid saturation determination method is applicable to material with T2 relaxation constants down to 8 ms. In the case of the 2D methods these constraints as a minimum enables work on the majority of chalk samples of Maastrichtian age. The 1D fluid saturation determination method in addition is applicable to at least some chalk samples of Danian and pre-Maastrichtian age. The spatial resolution of the 2D porosity determination method, the 1D fluid saturation methods, and the 2D fluid saturation method is respectively 0.8 mm, 0.8 mm and 2 mm. Reproducibility of pixel values is for all three methods 2%- points. (au)

  5. Traceability and measurement uncertainty in sample preparation (W5)

    International Nuclear Information System (INIS)

    Wegscheider, W.; Walner, U.; Moser, J.

    2002-01-01

    Full text: Very few chemical measurements are being made directly on the object of interest and sample preparation is thus the rule rather than the exception in daily practice. Unfortunately the operations undertaken in the course of sample preparation are prone to rendering a sample useless for the purpose of interpreting a measurement performed on it, as it might not represent the original and relevant status any longer. Sample preparation along with sampling itself constitutes therefore a procedure that leads to a loss of representation of the original specimen or population. On the other hand it is also not sufficient to confine aspects of traceability and measurement uncertainty to the ultimate measurement, as the key purpose of measuring is to supply adequate data for some kind of decision, be it in production, in health, in the environment, or indeed in any other circumstance. These considerations have led to severe confusion in the community as to what traceability really means in chemistry. CITAC and EURACHEM have only recently issued a preliminary document that clarifies these issues and gives a firm handle on the future development of quality assurance in analytical chemistry. In this talk it will be attempted to outline the general ideas and procedures that lead to traceability of analytical chemical results accompanied by valid statements of their uncertainty. It will be argued that the central element in achieving these goals is a well-designed validation study that frequently goes beyond those requirements currently laid out in official documents. (author)

  6. Optimized measurement of radium-226 concentration in liquid samples with radon-222 emanation

    International Nuclear Information System (INIS)

    Perrier, Frédéric; Aupiais, Jean; Girault, Frédéric; Przylibski, Tadeusz A.; Bouquerel, Hélène

    2016-01-01

    Measuring radium-226 concentration in liquid samples using radon-222 emanation remains competitive with techniques such as liquid scintillation, alpha or mass spectrometry. Indeed, we show that high-precision can be obtained without air circulation, using an optimal air to liquid volume ratio and moderate heating. Cost-effective and efficient measurement of radon concentration is achieved by scintillation flasks and sufficiently long counting times for signal and background. More than 400 such measurements were performed, including 39 dilution experiments, a successful blind measurement of six reference test solutions, and more than 110 repeated measurements. Under optimal conditions, uncertainties reach 5% for an activity concentration of 100 mBq L"−"1 and 10% for 10 mBq L"−"1. While the theoretical detection limit predicted by Monte Carlo simulation is around 3 mBq L"−"1, a conservative experimental estimate is rather 5 mBq L"−"1, corresponding to 0.14 fg g"−"1. The method was applied to 47 natural waters, 51 commercial waters, and 17 wine samples, illustrating that it could be an option for liquids that cannot be easily measured by other methods. Counting of scintillation flasks can be done in remote locations in absence of electricity supply, using a solar panel. Thus, this portable method, which has demonstrated sufficient accuracy for numerous natural liquids, could be useful in geological and environmental problems, with the additional benefit that it can be applied in isolated locations and in circumstances when samples cannot be transported. - Highlights: • Radium-226 concentration measured with optimized accumulation in a container. • Radon-222 in air measured precisely with scintillation flasks and long countings. • Method tested by repetition tests, dilution experiments, and successful blind tests. • Estimated conservative detection limit without pre-concentration is 5 mBq L"−"1. • Method is portable, cost

  7. STUDY OF HOME DEMONSTRATION UNITS IN A SAMPLE OF 27 COUNTIES IN NEW YORK STATE, NUMBER 3.

    Science.gov (United States)

    ALEXANDER, FRANK D.; HARSHAW, JEAN

    AN EXPLORATORY STUDY EXAMINED CHARACTERISTICS OF 1,128 HOME DEMONSTRATION UNITS TO SUGGEST HYPOTHESES AND SCOPE FOR A MORE INTENSIVE STUDY OF A SMALL SAMPLE OF UNITS, AND TO PROVIDE GUIDANCE IN SAMPLING. DATA WERE OBTAINED FROM A SPECIALLY DESIGNED MEMBERSHIP CARD USED IN 1962. UNIT SIZE AVERAGED 23.6 MEMBERS BUT THE RANGE WAS FAIRLY GREAT. A NEED…

  8. Double modulation pyrometry: A radiometric method to measure surface temperatures of directly irradiated samples

    Science.gov (United States)

    Potamias, Dimitrios; Alxneit, Ivo; Wokaun, Alexander

    2017-09-01

    The design, implementation, calibration, and assessment of double modulation pyrometry to measure surface temperatures of radiatively heated samples in our 1 kW imaging furnace is presented. The method requires that the intensity of the external radiation can be modulated. This was achieved by a rotating blade mounted parallel to the optical axis of the imaging furnace. Double modulation pyrometry independently measures the external radiation reflected by the sample as well as the sum of thermal and reflected radiation and extracts the thermal emission as the difference of these signals. Thus a two-step calibration is required: First, the relative gains of the measured signals are equalized and then a temperature calibration is performed. For the latter, we transfer the calibration from a calibrated solar blind pyrometer that operates at a different wavelength. We demonstrate that the worst case systematic error associated with this procedure is about 300 K but becomes negligible if a reasonable estimate of the sample's emissivity is used. An analysis of the influence of the uncertainties in the calibration coefficients reveals that one (out of the five) coefficient contributes almost 50% to the final temperature error. On a low emission sample like platinum, the lower detection limit is around 1700 K and the accuracy typically about 20 K. Note that these moderate specifications are specific for the use of double modulation pyrometry at the imaging furnace. It is mainly caused by the difficulty to achieve and maintain good overlap of the hot zone with a diameter of about 3 mm Full Width at Half Height and the measurement spot both of which are of similar size.

  9. Double modulation pyrometry: A radiometric method to measure surface temperatures of directly irradiated samples.

    Science.gov (United States)

    Potamias, Dimitrios; Alxneit, Ivo; Wokaun, Alexander

    2017-09-01

    The design, implementation, calibration, and assessment of double modulation pyrometry to measure surface temperatures of radiatively heated samples in our 1 kW imaging furnace is presented. The method requires that the intensity of the external radiation can be modulated. This was achieved by a rotating blade mounted parallel to the optical axis of the imaging furnace. Double modulation pyrometry independently measures the external radiation reflected by the sample as well as the sum of thermal and reflected radiation and extracts the thermal emission as the difference of these signals. Thus a two-step calibration is required: First, the relative gains of the measured signals are equalized and then a temperature calibration is performed. For the latter, we transfer the calibration from a calibrated solar blind pyrometer that operates at a different wavelength. We demonstrate that the worst case systematic error associated with this procedure is about 300 K but becomes negligible if a reasonable estimate of the sample's emissivity is used. An analysis of the influence of the uncertainties in the calibration coefficients reveals that one (out of the five) coefficient contributes almost 50% to the final temperature error. On a low emission sample like platinum, the lower detection limit is around 1700 K and the accuracy typically about 20 K. Note that these moderate specifications are specific for the use of double modulation pyrometry at the imaging furnace. It is mainly caused by the difficulty to achieve and maintain good overlap of the hot zone with a diameter of about 3 mm Full Width at Half Height and the measurement spot both of which are of similar size.

  10. Testing an ionization chamber with gaseous samples and measurements of the (n, alpha) reaction cross sections

    CERN Document Server

    Gledenov, Yu M; Salatskii, V I; Sedyshev, P V; Andrzejewski, J; Szalanski, P

    1999-01-01

    A new ionization chamber with gaseous samples (GIC) has been designed and tested on the thermal and resonance neutron beams of FLNP's neutron sources. The exposed gas volume serves as a target for neutrons. The obtained thermal cross sections for the sup 1 sup 7 O(n, alpha) sup 1 sup 4 C, sup 2 sup 1 Ne(n, alpha) sup 1 sup 8 O and sup 3 sup 6 Ar(n, alpha) sup 3 sup 3 S reactions are (233+-12) mb, (0.18+-0.09) mb and (5.43+-0.27) mb, respectively. These measurements have been performed on a pure beam of thermal neutrons from the high flux reactor IBR-2; and they demonstrated high efficiency and reliability of the method. Compared to samples on substrates, the application of gaseous samples makes the beam background essentially lower, and what is more important, the background component is totally absent due to the absence of Li and B microimpurities in gaseous samples while they do present in the samples on substrates. The method is also applicable to measurements with resonance neutrons. The recovery capabili...

  11. Analysis of reactivity worths of highly-burnt PWR fuel samples measured in LWR-PROTEUS Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Grimm, Peter; Murphy, Michael F.; Jatuff, Fabian; Seiler, Rudolf [Paul Scherrer Institute, CH-5232 Villigen PSI (Switzerland)

    2008-07-01

    The reactivity loss of PWR fuel with burnup has been determined experimentally by inserting fresh and highly-burnt fuel samples in a PWR test lattice in the framework of the LWR-PROTEUS Phase II programme. Seven UO{sub 2} samples irradiated in a Swiss PWR plant with burnups ranging from approx40 to approx120 MWd/kg and four MOX samples with burnups up to approx70 MWd/kg were oscillated in a test region constituted of actual PWR UO{sub 2} fuel rods in the centre of the PROTEUS zero-power experimental facility. The measurements were analyzed using the CASMO-4E fuel assembly code and a cross section library based on the ENDF/B-VI evaluation. The results show close proximity between calculated and measured reactivity effects and no trend for a deterioration of the quality of the prediction at high burnup. The analysis thus demonstrates the high accuracy of the calculation of the reactivity of highly-burnt fuel. (authors)

  12. Radiocarbon measurements of tree-ring samples from Japanese woods

    International Nuclear Information System (INIS)

    Ozaki, Hiromasa; Sakamoto, Minoru; Imamura, Mineo; Mitsutani, Takumi

    2008-01-01

    Since radiocarbon age is a model age based on constancy of atmospheric radiocarbon concentration and a provisional value of 5568 years for the 14 C half-life, calibration to calendar age is required for practical dating. The dataset, called IntCal, used for the calibration has been constructed by international consortium. Most parts of the IntCal have been based on the measurement of radiocarbon in dendrochronologically dated tree-ring samples from woods in Europe and North America. Regional offsets, which are designed as differences of local atmospheric radiocarbon from IntCal, have been pointed out based on recent radiocarbon measurements for tree-ring samples from a few regions. We have also measured radiocarbon of tree-ring samples from Japanese woods in order to investigate regional offsets in Japan. In this study, radiocarbon measurements for tree-ring samples from three different Japanese woods at around AD500 were carried out. Consequently, differences from IntCal04 at around AD500 were confirmed, although no systematic offset are found. However, the results obtained in this study agree with the raw data used for construction of IntCal04. This could pose a question to calculation method of IntCal04. (author)

  13. Time optimization of 90Sr measurements: Sequential measurement of multiple samples during ingrowth of 90Y

    International Nuclear Information System (INIS)

    Holmgren, Stina; Tovedal, Annika; Björnham, Oscar; Ramebäck, Henrik

    2016-01-01

    The aim of this paper is to contribute to a more rapid determination of a series of samples containing 90 Sr by making the Cherenkov measurement of the daughter nuclide 90 Y more time efficient. There are many instances when an optimization of the measurement method might be favorable, such as; situations requiring rapid results in order to make urgent decisions or, on the other hand, to maximize the throughput of samples in a limited available time span. In order to minimize the total analysis time, a mathematical model was developed which calculates the time of ingrowth as well as individual measurement times for n samples in a series. This work is focused on the measurement of 90 Y during ingrowth, after an initial chemical separation of strontium, in which it is assumed that no other radioactive strontium isotopes are present. By using a fixed minimum detectable activity (MDA) and iterating the measurement time for each consecutive sample the total analysis time will be less, compared to using the same measurement time for all samples. It was found that by optimization, the total analysis time for 10 samples can be decreased greatly, from 21 h to 6.5 h, when assuming a MDA of 1 Bq/L and at a background count rate of approximately 0.8 cpm. - Highlights: • An approach roughly a factor of three more efficient than an un-optimized method. • The optimization gives a more efficient use of instrument time. • The efficiency increase ranges from a factor of three to 10, for 10 to 40 samples.

  14. Sampling Approaches for Multi-Domain Internet Performance Measurement Infrastructures

    Energy Technology Data Exchange (ETDEWEB)

    Calyam, Prasad

    2014-09-15

    The next-generation of high-performance networks being developed in DOE communities are critical for supporting current and emerging data-intensive science applications. The goal of this project is to investigate multi-domain network status sampling techniques and tools to measure/analyze performance, and thereby provide “network awareness” to end-users and network operators in DOE communities. We leverage the infrastructure and datasets available through perfSONAR, which is a multi-domain measurement framework that has been widely deployed in high-performance computing and networking communities; the DOE community is a core developer and the largest adopter of perfSONAR. Our investigations include development of semantic scheduling algorithms, measurement federation policies, and tools to sample multi-domain and multi-layer network status within perfSONAR deployments. We validate our algorithms and policies with end-to-end measurement analysis tools for various monitoring objectives such as network weather forecasting, anomaly detection, and fault-diagnosis. In addition, we develop a multi-domain architecture for an enterprise-specific perfSONAR deployment that can implement monitoring-objective based sampling and that adheres to any domain-specific measurement policies.

  15. Trapped field measurements on MgB{sub 2} bulk samples

    Energy Technology Data Exchange (ETDEWEB)

    Koblischka, Michael; Karwoth, Thomas; Zeng, XianLin; Hartmann, Uwe [Institute of Experimental Physics, Saarland University, P. O. Box 151150, D-66041 Saarbruecken (Germany); Berger, Kevin; Douine, Bruno [University of Lorraine, GREEN, 54506 Vandoeuvre-les-Nancy (France)

    2016-07-01

    Trapped field measurements were performed on bulk, polycrystalline MgB{sub 2} samples stemming from different sources with the emphasis to develop applications like superconducting permanent magnets ('supermagnets') and electric motors. We describe the setup for the trapped field measurements and the experimental procedure (field cooling, zero-field cooling, field sweep rates). The trapped field measurements were conducted using a cryocooling system to cool the bulk samples to the desired temperatures, and a low-loss cryostat equipped with a room-temperature bore and a maximum field of ±5 T was employed to provide the external magnetic field. The superconducting coil of this cryostat is operated using a bidirectional power supply. Various sweep rates of the external magnetic field ranging between 1 mT/s and 40 mT/s were used to generate the applied field. The measurements were performed with one sample and two samples stacked together. A maximum trapped field of 7 T was recorded. We discuss the results obtained and the problems arising due to flux jumping, which is often seen for the MgB{sub 2} samples cooled to temperatures below 10 K.

  16. Relativistic rise measurements with very fine sampling intervals

    International Nuclear Information System (INIS)

    Ludlam, T.; Platner, E.D.; Polychronakos, V.A.; Lindenbaum, S.J.; Kramer, M.A.; Teramoto, Y.

    1980-01-01

    The motivation of this work was to determine whether the technique of charged particle identification via the relativistic rise in the ionization loss can be significantly improved by virtue of very small sampling intervals. A fast-sampling ADC and a longitudinal drift geometry were used to provide a large number of samples from a single drift chamber gap, achieving sampling intervals roughly 10 times smaller than any previous study. A single layer drift chamber was used, and tracks of 1 meter length were simulated by combining together samples from many identified particles in this detector. These data were used to study the resolving power for particle identification as a function of sample size, averaging technique, and the number of discrimination levels (ADC bits) used for pulse height measurements

  17. Approximate determination of efficiency for activity measurements of cylindrical samples

    Energy Technology Data Exchange (ETDEWEB)

    Helbig, W [Nuclear Engineering and Analytics Rossendorf, Inc. (VKTA), Dresden (Germany); Bothe, M [Nuclear Engineering and Analytics Rossendorf, Inc. (VKTA), Dresden (Germany)

    1997-03-01

    Some calibration samples are necessary with the same geometrical parameters but of different materials, containing known activities A homogeniously distributed. Their densities are measured, their mass absorption coefficients may be unknown. These calibration samples are positioned in the counting geometry, for instance directly on the detector. The efficiency function {epsilon}(E) for each sample is gained by measuring the gamma spectra and evaluating all usable gamma energy peaks. From these {epsilon}(E) the common valid {epsilon}{sub geom}(E) will be deduced. For this purpose the functions {epsilon}{sub mu}(E) for these samples have to be established. (orig.)

  18. A method to correct sampling ghosts in historic near-infrared Fourier transform spectrometer (FTS) measurements

    Science.gov (United States)

    Dohe, S.; Sherlock, V.; Hase, F.; Gisi, M.; Robinson, J.; Sepúlveda, E.; Schneider, M.; Blumenstock, T.

    2013-08-01

    The Total Carbon Column Observing Network (TCCON) has been established to provide ground-based remote sensing measurements of the column-averaged dry air mole fractions (DMF) of key greenhouse gases. To ensure network-wide consistency, biases between Fourier transform spectrometers at different sites have to be well controlled. Errors in interferogram sampling can introduce significant biases in retrievals. In this study we investigate a two-step scheme to correct these errors. In the first step the laser sampling error (LSE) is estimated by determining the sampling shift which minimises the magnitude of the signal intensity in selected, fully absorbed regions of the solar spectrum. The LSE is estimated for every day with measurements which meet certain selection criteria to derive the site-specific time series of the LSEs. In the second step, this sequence of LSEs is used to resample all the interferograms acquired at the site, and hence correct the sampling errors. Measurements acquired at the Izaña and Lauder TCCON sites are used to demonstrate the method. At both sites the sampling error histories show changes in LSE due to instrument interventions (e.g. realignment). Estimated LSEs are in good agreement with sampling errors inferred from the ratio of primary and ghost spectral signatures in optically bandpass-limited tungsten lamp spectra acquired at Lauder. The original time series of Xair and XCO2 (XY: column-averaged DMF of the target gas Y) at both sites show discrepancies of 0.2-0.5% due to changes in the LSE associated with instrument interventions or changes in the measurement sample rate. After resampling, discrepancies are reduced to 0.1% or less at Lauder and 0.2% at Izaña. In the latter case, coincident changes in interferometer alignment may also have contributed to the residual difference. In the future the proposed method will be used to correct historical spectra at all TCCON sites.

  19. A method to correct sampling ghosts in historic near-infrared Fourier transform spectrometer (FTS measurements

    Directory of Open Access Journals (Sweden)

    S. Dohe

    2013-08-01

    Full Text Available The Total Carbon Column Observing Network (TCCON has been established to provide ground-based remote sensing measurements of the column-averaged dry air mole fractions (DMF of key greenhouse gases. To ensure network-wide consistency, biases between Fourier transform spectrometers at different sites have to be well controlled. Errors in interferogram sampling can introduce significant biases in retrievals. In this study we investigate a two-step scheme to correct these errors. In the first step the laser sampling error (LSE is estimated by determining the sampling shift which minimises the magnitude of the signal intensity in selected, fully absorbed regions of the solar spectrum. The LSE is estimated for every day with measurements which meet certain selection criteria to derive the site-specific time series of the LSEs. In the second step, this sequence of LSEs is used to resample all the interferograms acquired at the site, and hence correct the sampling errors. Measurements acquired at the Izaña and Lauder TCCON sites are used to demonstrate the method. At both sites the sampling error histories show changes in LSE due to instrument interventions (e.g. realignment. Estimated LSEs are in good agreement with sampling errors inferred from the ratio of primary and ghost spectral signatures in optically bandpass-limited tungsten lamp spectra acquired at Lauder. The original time series of Xair and XCO2 (XY: column-averaged DMF of the target gas Y at both sites show discrepancies of 0.2–0.5% due to changes in the LSE associated with instrument interventions or changes in the measurement sample rate. After resampling, discrepancies are reduced to 0.1% or less at Lauder and 0.2% at Izaña. In the latter case, coincident changes in interferometer alignment may also have contributed to the residual difference. In the future the proposed method will be used to correct historical spectra at all TCCON sites.

  20. An antithetic variate to facilitate upper-stem height measurements for critical height sampling with importance sampling

    Science.gov (United States)

    Thomas B. Lynch; Jeffrey H. Gove

    2013-01-01

    Critical height sampling (CHS) estimates cubic volume per unit area by multiplying the sum of critical heights measured on trees tallied in a horizontal point sample (HPS) by the HPS basal area factor. One of the barriers to practical application of CHS is the fact that trees near the field location of the point-sampling sample point have critical heights that occur...

  1. Surface Resistance Measurements of LHC Dipole Beam Screen Samples

    CERN Document Server

    Caspers, Friedhelm; Ruggiero, F; Tan, J; Tsutsui, H

    2000-01-01

    An estimate of the resistive losses in the LHC dipole beam screen is given from cold surface resistance measurements using the shielded pair technique. Several beam screen samples have been evaluated, with different copper coating methods, including a sample with ribbed surface envisaged to reduce electron cloud losses thanks to its low reflectivity. Experimental data, derived by a proper analysis of the measured Q-factors and including error estimates are compared with theoretical predictions of the anomalous skin effect.

  2. A study of toxic emissions from a coal-fired power plant utilizing the SNOX innovative clean coal technology demonstration. Volume 1, Sampling/results/special topics: Final report

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    This study was one of a group of assessments of toxic emissions from coal-fired power plants, conducted for DOE during 1993. The motivation for those assessments was the mandate in the 1990 Clean Air Act Amendments that a study be made of emissions of hazardous air pollutants (HAPs) from electric utilities. The report is organized in two volumes. Volume 1: Sampling describes the sampling effort conducted as the basis for this study; Results presents the concentration data on HAPs in the several power plant streams, and reports the results of evaluations and calculations conducted with those data; and Special Topics report on issues such as comparison of sampling methods and vapor/solid distributions of HAPs. Volume 2: Appendices include quality assurance/quality control results, uncertainty analysis for emission factors, and data sheets. This study involved measurements of a variety of substances in solid, liquid, and gaseous samples from input, output, and process streams at the Innovative Clean Coal Technology Demonstration (ICCT) of the Wet Sulfuric Acid-Selective Catalytic Reduction (SNOX) process. The SNOX demonstration is being conducted at Ohio Edison`s Niles Boiler No. 2 which uses cyclone burners to burn bituminous coal. A 35 megawatt slipstream of flue gas from the boiler is used to demonstrate SNOX. The substances measured at the SNOX process were the following: 1. Five major and 16 trace elements, including mercury, chromium, cadmium, lead, selenium, arsenic, beryllium, and nickel; 2. Acids and corresponding anions (HCl, HF, chloride, fluoride, phosphate, sulfate); 3. Ammonia and cyanide; 4. Elemental carbon; 5. Radionuclides; 6. Volatile organic compounds (VOC); 7. Semi-volatile compounds (SVOC) including polynuclear aromatic hydrocarbons (PAH); and 8. Aldehydes.

  3. Sample-size effects in fast-neutron gamma-ray production measurements: solid-cylinder samples

    International Nuclear Information System (INIS)

    Smith, D.L.

    1975-09-01

    The effects of geometry, absorption and multiple scattering in (n,Xγ) reaction measurements with solid-cylinder samples are investigated. Both analytical and Monte-Carlo methods are employed in the analysis. Geometric effects are shown to be relatively insignificant except in definition of the scattering angles. However, absorption and multiple-scattering effects are quite important; accurate microscopic differential cross sections can be extracted from experimental data only after a careful determination of corrections for these processes. The results of measurements performed using several natural iron samples (covering a wide range of sizes) confirm validity of the correction procedures described herein. It is concluded that these procedures are reliable whenever sufficiently accurate neutron and photon cross section and angular distribution information is available for the analysis. (13 figures, 5 tables) (auth)

  4. Demonstration and uncertainty analysis of synchronised scanning lidar measurements of 2-D velocity fields in a boundary-layer wind tunnel

    DEFF Research Database (Denmark)

    van Dooren, Marijn Floris; Campagnolo, Filippo; Sjöholm, Mikael

    2017-01-01

    to demonstrate the benefits of synchronised scanning lidars in such experimental surroundings for the first time. The duallidar system can provide fully synchronised trajectory scans with sampling timescales ranging from seconds to minutes. First, staring mode measurements were compared to hot-wire probe...... as wake area scans were executed to illustrate the applicability of lidar scanning to the measurement of small-scale wind flow effects. An extensive uncertainty analysis was executed to assess the accuracy of the method. The downsides of lidar with respect to the hotwire probes are the larger measurement...... probe volume, which compromises the ability to measure turbulence, and the possible loss of a small part of the measurements due to hard target beam reflection. In contrast, the benefits are the high flexibility in conducting both point measurements and area scanning and the fact that remote sensing...

  5. Activation Measurements for Thermal Neutrons, Part D. U.S. Measurements of 36Cl in Mineral Samples from Hiroshima and Nagasaki

    International Nuclear Information System (INIS)

    Tore Straume; Alfredo A, Marchetti; Stephen D, Egbert; James A, Roberts; Ping Men; Shoichiro Fujita; Kiyoshi Shizuma; Masaharu Hoshi; G, Rugel; W, Ruhm; G, Korschinek; J. E. McAninch; K. L. Carroll; T. Faestermann; K. Knie; R. E. Martinelli; A. Wallner; C. Wallner

    2005-01-01

    The present paper presents the 36 Cl measurement effort in the US. A large number of 36 Cl measurements have been made in both granite and concrete samples obtained from various locations and distances in Hiroshima and Nagasaki. These measurements employed accelerator mass spectrometry (AMS) to quantify the number of atoms of 36 Cl per atom of total Cl in the sample. Results from these measurements are presented here and discussed in the context of the DS02 dosimetry reevaluation effort for Hiroshima and Nagasaki atomic-bomb survivors. The production of 36 Cl by bomb neutrons in mineral samples from Hiroshima and Nagasaki was primarily via the reaction 35 Cl(n,γ) 36 Cl. This reaction has a substantial thermal neutron cross-section (43.6 b at 0.025 eV) and the product has a long half-life (301,000 y). hence, it is well suited for neutron-activation detection in Hiroshima and Nagasaki using AMS more than 50 years after the bombings. A less important reaction for bomb neutrons, 39 K(n,α) 36 Cl, typically produces less than 10% of the 36 Cl in mineral samples such as granite and concrete, which contain ∼ 2% potassium. In 1988, only a year after the publication of the DS86 final report (Roesch 1987), it was demonstrated experimentally that 36 Cl measured using AMS should be able to detect the thermal neutron fluences at the large distances most relevant to the A-bomb survivor dosimetry. Subsequent measurements in mineral samples from both Hiroshima and Nagasaki validated the experimental findings. The potential utility of 36 Cl as a thermal neutron detector in Hiroshima was first presented by Haberstock et al. who employed the Munich AMS facility to measure 36 Cl/Cl ratios in a gravestone from near the hypocenter. That work subsequently resulted in an expanded 36 Cl effort in Germany that paralleled the US work. More recently, there have also been 36 Cl measurements made by a Japanese group. The impetus for the extensive 36 Cl and other neutron activation

  6. A development of two-dimensional birefringence distribution measurement system with a sampling rate of 1.3 MHz

    Science.gov (United States)

    Onuma, Takashi; Otani, Yukitoshi

    2014-03-01

    A two-dimensional birefringence distribution measurement system with a sampling rate of 1.3 MHz is proposed. A polarization image sensor is developed as core device of the system. It is composed of a pixelated polarizer array made from photonic crystal and a parallel read out circuit with a multi-channel analog to digital converter specialized for two-dimensional polarization detection. By applying phase shifting algorism with circularly-polarized incident light, birefringence phase difference and azimuthal angle can be measured. The performance of the system is demonstrated experimentally by measuring actual birefringence distribution and polarization device such as Babinet-Soleil compensator.

  7. Device to investigate samples by means of flameless atomic absorption measurement

    International Nuclear Information System (INIS)

    Sperling, K.R.

    1977-01-01

    An improvement on a device to investigate samples by means of flameless atomic absorption measurement is suggested in which one aims to produce a most complete possible atomic clond from the sample to be investigated within the sample space defined by the beam bundle, through which the measuring beam bundle is passed. According to the invention, the tubular sample space should be closed by an optically penetrable window on one side. (RW) [de

  8. Attempts to develop a new nuclear measurement technique of β-glucuronidase levels in biological samples

    International Nuclear Information System (INIS)

    Unak, T.; Avcibasi, U.; Yildirim, Y.; Cetinkaya, B.

    2003-01-01

    phenolphthalein or aniline could easily be detected at least 10 6 times more sensitively. The preliminary results obtained on some biological samples have shown that β-glucuronidase levels could reasonably be measured by use of the nuclear technique. In addition, our results also indicate the potential application of the radiolabelling technique to measure very low β-glucuronidase levels in different biological samples in cancer research and other related fields. The objective of our study is to demonstrate the potential application of the nuclear measurement technique in different biological samples. (author)

  9. Evaluation of a lower-powered analyzer and sampling system for eddy-covariance measurements of nitrous oxide fluxes

    Directory of Open Access Journals (Sweden)

    S. E. Brown

    2018-03-01

    Full Text Available Nitrous oxide (N2O fluxes measured using the eddy-covariance method capture the spatial and temporal heterogeneity of N2O emissions. Most closed-path trace-gas analyzers for eddy-covariance measurements have large-volume, multi-pass absorption cells that necessitate high flow rates for ample frequency response, thus requiring high-power sample pumps. Other sampling system components, including rain caps, filters, dryers, and tubing, can also degrade system frequency response. This field trial tested the performance of a closed-path eddy-covariance system for N2O flux measurements with improvements to use less power while maintaining the frequency response. The new system consists of a thermoelectrically cooled tunable diode laser absorption spectrometer configured to measure both N2O and carbon dioxide (CO2. The system features a relatively small, single-pass sample cell (200 mL that provides good frequency response with a lower-powered pump ( ∼  250 W. A new filterless intake removes particulates from the sample air stream with no additional mixing volume that could degrade frequency response. A single-tube dryer removes water vapour from the sample to avoid the need for density or spectroscopic corrections, while maintaining frequency response. This eddy-covariance system was collocated with a previous tunable diode laser absorption spectrometer model to compare N2O and CO2 flux measurements for two full growing seasons (May 2015 to October 2016 in a fertilized cornfield in Southern Ontario, Canada. Both spectrometers were placed outdoors at the base of the sampling tower, demonstrating ruggedness for a range of environmental conditions (minimum to maximum daily temperature range: −26.1 to 31.6 °C. The new system rarely required maintenance. An in situ frequency-response test demonstrated that the cutoff frequency of the new system was better than the old system (3.5 Hz compared to 2.30 Hz and similar to that of a closed

  10. Evaluation of a lower-powered analyzer and sampling system for eddy-covariance measurements of nitrous oxide fluxes

    Science.gov (United States)

    Brown, Shannon E.; Sargent, Steve; Wagner-Riddle, Claudia

    2018-03-01

    Nitrous oxide (N2O) fluxes measured using the eddy-covariance method capture the spatial and temporal heterogeneity of N2O emissions. Most closed-path trace-gas analyzers for eddy-covariance measurements have large-volume, multi-pass absorption cells that necessitate high flow rates for ample frequency response, thus requiring high-power sample pumps. Other sampling system components, including rain caps, filters, dryers, and tubing, can also degrade system frequency response. This field trial tested the performance of a closed-path eddy-covariance system for N2O flux measurements with improvements to use less power while maintaining the frequency response. The new system consists of a thermoelectrically cooled tunable diode laser absorption spectrometer configured to measure both N2O and carbon dioxide (CO2). The system features a relatively small, single-pass sample cell (200 mL) that provides good frequency response with a lower-powered pump ( ˜ 250 W). A new filterless intake removes particulates from the sample air stream with no additional mixing volume that could degrade frequency response. A single-tube dryer removes water vapour from the sample to avoid the need for density or spectroscopic corrections, while maintaining frequency response. This eddy-covariance system was collocated with a previous tunable diode laser absorption spectrometer model to compare N2O and CO2 flux measurements for two full growing seasons (May 2015 to October 2016) in a fertilized cornfield in Southern Ontario, Canada. Both spectrometers were placed outdoors at the base of the sampling tower, demonstrating ruggedness for a range of environmental conditions (minimum to maximum daily temperature range: -26.1 to 31.6 °C). The new system rarely required maintenance. An in situ frequency-response test demonstrated that the cutoff frequency of the new system was better than the old system (3.5 Hz compared to 2.30 Hz) and similar to that of a closed-path CO2 eddy-covariance system (4

  11. Demonstrating the reliability of transdiagnostic mHealth Routine Outcome Monitoring in mental health services using experience sampling technology.

    Directory of Open Access Journals (Sweden)

    Simone J W Verhagen

    Full Text Available Routine Outcome Monitoring (ROM should provide a dynamic, within-treatment forward feedback loop to guide individual treatment decisions across diagnostic categories. It has been suggested that the Experience Sampling Method (ESM, capturing the film of daily life adaptive processes, offers a flexible, personalised and transdiagnostic feedback system for monitoring and adapting treatment strategies. This is the first study that uses an ESM application (the PsyMate™ as a routine mobile-ROM (mROM tool in an ambulatory mental health setting.To demonstrate adequate psychometric properties of the PsyMate™ app assessing both symptom severity levels as well as daily life functioning.In a transdiagnostic sample of 64 outpatients, an mROM protocol (ESM for 6 days, at 10 semi-random moments a day and a standard ROM instrument (HADS were administered at baseline and at three-month follow-up. We measured positive affect (PA, negative affect (NA, quality of sleep, positive social interaction, activity-related stress, tiredness, and feeling unwell.Subjects completed 53% of the measurements at baseline (N = 64 and 48% at follow-up (N = 29. Factor analysis and subsequent reliability analysis of PA and NA confirmed the two constructs. Significant and meaningful correlations were found between PA, NA and HADS scores (ranging from r = .4 to r = .7. Multilevel analyses yielded significant change scores for all measures.The ESM-based, transdiagnostic mROM tool can be used reliably in clinical settings: it shows adequate psychometric properties, as well as concurrent validity and sensitivity to change over time with respect to relevant ROM constructs. Person-tailored items can be added. In addition, mROM offers added value over standard symptom-based ROM, as it provides information on adaptive functioning in the daily environment of patients.

  12. Measurement of the deuterium concentration in water samples using a CW chemical deuterium fluoride laser

    International Nuclear Information System (INIS)

    Trautmann, M.

    1979-10-01

    In this study a new method for the determination of the deuterium content in water samples is described. The absorption of the radiation of a CW deuterium fluoride laser by the isotope HDO in the water vapor of the sample is measured by means of an optoacoustic detector (spectrophone). Thereby advantage is taken of the fact that H 2 O hardly absorbs the laser radiation and that D 2 O only exists in negligible concentrations. The isotope ratio of hydrogen can be calculated from the measured relative concentration of HDO. In the course of this investigation the relative absorption cross sections of HDO for the different laser lines were determined. It was thereby established that there exists a very good coincidence of an HDO absorption line with the 2P2 laser line. Using a very sensitive nonresonant spectrophone the relative concentration of HDO in natural water samples could be determined with an accuracy of about 10%. The experiments also demonstrated that with appropriate improvements made to the apparatus and using a second spectrophone as a reference it should be possible to increase this accuracy to 0,1%. (orig.)

  13. Quantitative photoacoustic integrating sphere (QPAIS platform for absorption coefficient and Grüneisen parameter measurements: Demonstration with human blood

    Directory of Open Access Journals (Sweden)

    Yolanda Villanueva-Palero

    2017-06-01

    Full Text Available Quantitative photoacoustic imaging in biomedicine relies on accurate measurements of relevant material properties of target absorbers. Here, we present a method for simultaneous measurements of the absorption coefficient and Grüneisen parameter of small volume of liquid scattering and absorbing media using a coupled-integrating sphere system which we refer to as quantitative photoacoustic integrating sphere (QPAIS platform. The derived equations do not require absolute magnitudes of optical energy and pressure values, only calibration of the setup using aqueous ink dilutions is necessary. As a demonstration, measurements with blood samples from various human donors are done at room and body temperatures using an incubator. Measured absorption coefficient values are consistent with known oxygen saturation dependence of blood absorption at 750 nm, whereas measured Grüneisen parameter values indicate variability among five different donors. An increasing Grüneisen parameter value with both hematocrit and temperature is observed. These observations are consistent with those reported in literature.

  14. Measurement of radioactive lines in powdered milk samples in Londrina (Parana State, Brazil) region

    International Nuclear Information System (INIS)

    Melquiades, Fabio Luiz

    2000-01-01

    This work deals with the measurement of radioactive lines in powdered milk, with high resolution gamma spectrometry, using a HPGe detector with relative efficiency of 10%, coupled to the electronic nuclear chain and a multichannel card of 8192 channels. Some tests were realized before beginning the measurements. The first of them was to define the shield to be used, making several measured with different shields according to the available materials, opting finally for a shield composed of bricks of lead (10 cm thickness), plates of iron (4nm thickness) and of aluminum (2 mm thickness). Four different geometries for the samples recipients were tested, and the Marinelli beaker of 2,1 liters totally filled was the one which supplied the best peak/background ratio. A statistical inference was also realized to determine the sampling that represents each one of the lots of milk to be measured, resulting in a number of 6 samples, for a confidence level of 95%. Two different kinds of powdered milk produced at Londrina were analyzed, Integral Powdered Milk Cativa and Integral Powdered Milk Polly. The samples were properly put in the Marinelli beaker of 2,1 L, sealed and kept for 40 days to reach the secular equilibrium. The counting time for each measurement was two days. It was possible to identify the radionuclides 40 K, 137 Cs and 232 Th (from 208 Tl), whose activities were calculated according to the International Atomic Energy Agency norms (IAEA, 1989). The detector efficiency was measured using calibrated samples, prepared with the certified reference materials IAEA-326 and IAEA-375. Corrections for self-absorption were accomplished, based on measures of samples with different densities. The results obtained for the powdered milk Cativa were: 464± 12 Bq/kg for 40 K, 3,46 ± 1,05 and 0,46 ± 1,05 and 0,46 ± 0,16 Bq/kg for the minimum detectable activities of 137 Cs and 232 Th, respectively. For the milk Polly, the results were: 452±10 Bq/kg for 40 K, 3,19 ± 0

  15. Considerations on measurements of radioactivity in biological samples

    International Nuclear Information System (INIS)

    Mascanzoni, D.

    1986-01-01

    Radioactivity in biological samples and particularly in foodstuffs can be measured with several procedures, depending on the type of sample and radiation. In case of a radioactive fallout like the one from Chernobyl 1986, contamination in biological samples varies with time, being high immediately after the accident and decreasing successively with time. During the first stage, accurate measurements of gamma-emission should be made with high-resolution instruments, like HPGe-detectors coupled to multichannel analyzers in order to be able to assess the fallout's composition and separate the different nuclides. Even portable GM-counters and NaI(Tl)-detectors can be used, but they provide very limited information and the resolution of NaI(Tl) is too poor to make them suitable for other than survey purposes. In this case, they can be used for monitoring the activity in a certain area, or scanning a large amount of samples. After some months, when the activity has decayed and only a few nuclides are still active, the most important parameter is not resolution any longer, but sensitivity, since the content of radionuclides has decreased. At this stage NaI(Tl)-detectors assume greater importance and their sensitivity can permit the detection of low activity levels in relatively short time. The laboratory procedures for sample handling and preparation is also very important: established routines concentrated upon reducing the risk of contamination and minimizing sources of error must be used

  16. Comparison of halocarbon measurements in an atmospheric dry whole air sample.

    Science.gov (United States)

    Rhoderick, George C; Hall, Bradley D; Harth, Christina M; Kim, Jin Seog; Lee, Jeongsoon; Montzka, Stephen A; Mühle, Jens; Reimann, Stefan; Vollmer, Martin K; Weiss, Ray F

    The growing awareness of climate change/global warming, and continuing concerns regarding stratospheric ozone depletion, will require continued measurements and standards for many compounds, in particular halocarbons that are linked to these issues. In order to track atmospheric mole fractions and assess the impact of policy on emission rates, it is necessary to demonstrate measurement equivalence at the highest levels of accuracy for assigned values of standards. Precise measurements of these species aid in determining small changes in their atmospheric abundance. A common source of standards/scales and/or well-documented agreement of different scales used to calibrate the measurement instrumentation are key to understanding many sets of data reported by researchers. This report describes the results of a comparison study among National Metrology Institutes and atmospheric research laboratories for the chlorofluorocarbons (CFCs) dichlorodifluoromethane (CFC-12), trichlorofluoromethane (CFC-11), and 1,1,2-trichlorotrifluoroethane (CFC-113); the hydrochlorofluorocarbons (HCFCs) chlorodifluoromethane (HCFC-22) and 1-chloro-1,1-difluoroethane (HCFC-142b); and the hydrofluorocarbon (HFC) 1,1,1,2-tetrafluoroethane (HFC-134a), all in a dried whole air sample. The objective of this study is to compare calibration standards/scales and the measurement capabilities of the participants for these halocarbons at trace atmospheric levels. The results of this study show agreement among four independent calibration scales to better than 2.5% in almost all cases, with many of the reported agreements being better than 1.0%.

  17. Comparison of halocarbon measurements in an atmospheric dry whole air sample

    Directory of Open Access Journals (Sweden)

    George C. Rhoderick

    2015-11-01

    Full Text Available Abstract The growing awareness of climate change/global warming, and continuing concerns regarding stratospheric ozone depletion, will require continued measurements and standards for many compounds, in particular halocarbons that are linked to these issues. In order to track atmospheric mole fractions and assess the impact of policy on emission rates, it is necessary to demonstrate measurement equivalence at the highest levels of accuracy for assigned values of standards. Precise measurements of these species aid in determining small changes in their atmospheric abundance. A common source of standards/scales and/or well-documented agreement of different scales used to calibrate the measurement instrumentation are key to understanding many sets of data reported by researchers. This report describes the results of a comparison study among National Metrology Institutes and atmospheric research laboratories for the chlorofluorocarbons (CFCs dichlorodifluoromethane (CFC-12, trichlorofluoromethane (CFC-11, and 1,1,2-trichlorotrifluoroethane (CFC-113; the hydrochlorofluorocarbons (HCFCs chlorodifluoromethane (HCFC-22 and 1-chloro-1,1-difluoroethane (HCFC-142b; and the hydrofluorocarbon (HFC 1,1,1,2-tetrafluoroethane (HFC-134a, all in a dried whole air sample. The objective of this study is to compare calibration standards/scales and the measurement capabilities of the participants for these halocarbons at trace atmospheric levels. The results of this study show agreement among four independent calibration scales to better than 2.5% in almost all cases, with many of the reported agreements being better than 1.0%.

  18. Comparison of halocarbon measurements in an atmospheric dry whole air sample

    Science.gov (United States)

    Hall, Bradley D.; Harth, Christina M.; Kim, Jin Seog; Lee, Jeongsoon; Montzka, Stephen A.; Mühle, Jens; Reimann, Stefan; Vollmer, Martin K.; Weiss, Ray F.

    2015-01-01

    The growing awareness of climate change/global warming, and continuing concerns regarding stratospheric ozone depletion, will require continued measurements and standards for many compounds, in particular halocarbons that are linked to these issues. In order to track atmospheric mole fractions and assess the impact of policy on emission rates, it is necessary to demonstrate measurement equivalence at the highest levels of accuracy for assigned values of standards. Precise measurements of these species aid in determining small changes in their atmospheric abundance. A common source of standards/scales and/or well-documented agreement of different scales used to calibrate the measurement instrumentation are key to understanding many sets of data reported by researchers. This report describes the results of a comparison study among National Metrology Institutes and atmospheric research laboratories for the chlorofluorocarbons (CFCs) dichlorodifluoromethane (CFC-12), trichlorofluoromethane (CFC-11), and 1,1,2-trichlorotrifluoroethane (CFC-113); the hydrochlorofluorocarbons (HCFCs) chlorodifluoromethane (HCFC-22) and 1-chloro-1,1-difluoroethane (HCFC-142b); and the hydrofluorocarbon (HFC) 1,1,1,2-tetrafluoroethane (HFC-134a), all in a dried whole air sample. The objective of this study is to compare calibration standards/scales and the measurement capabilities of the participants for these halocarbons at trace atmospheric levels. The results of this study show agreement among four independent calibration scales to better than 2.5% in almost all cases, with many of the reported agreements being better than 1.0%. PMID:26753167

  19. Sampling and Control Circuit Board for an Inertial Measurement Unit

    Science.gov (United States)

    Chelmins, David T (Inventor); Powis, Richard T., Jr. (Inventor); Sands, Obed (Inventor)

    2016-01-01

    A circuit board that serves as a control and sampling interface to an inertial measurement unit ("IMU") is provided. The circuit board is also configured to interface with a local oscillator and an external trigger pulse. The circuit board is further configured to receive the external trigger pulse from an external source that time aligns the local oscillator and initiates sampling of the inertial measurement device for data at precise time intervals based on pulses from the local oscillator. The sampled data may be synchronized by the circuit board with other sensors of a navigation system via the trigger pulse.

  20. Estimation of Uncertainty in Aerosol Concentration Measured by Aerosol Sampling System

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Chan; Song, Yong Jae; Jung, Woo Young; Lee, Hyun Chul; Kim, Gyu Tae; Lee, Doo Yong [FNC Technology Co., Yongin (Korea, Republic of)

    2016-10-15

    FNC Technology Co., Ltd has been developed test facilities for the aerosol generation, mixing, sampling and measurement under high pressure and high temperature conditions. The aerosol generation system is connected to the aerosol mixing system which injects SiO{sub 2}/ethanol mixture. In the sampling system, glass fiber membrane filter has been used to measure average mass concentration. Based on the experimental results using main carrier gas of steam and air mixture, the uncertainty estimation of the sampled aerosol concentration was performed by applying Gaussian error propagation law. FNC Technology Co., Ltd. has been developed the experimental facilities for the aerosol measurement under high pressure and high temperature. The purpose of the tests is to develop commercial test module for aerosol generation, mixing and sampling system applicable to environmental industry and safety related system in nuclear power plant. For the uncertainty calculation of aerosol concentration, the value of the sampled aerosol concentration is not measured directly, but must be calculated from other quantities. The uncertainty of the sampled aerosol concentration is a function of flow rates of air and steam, sampled mass, sampling time, condensed steam mass and its absolute errors. These variables propagate to the combination of variables in the function. Using operating parameters and its single errors from the aerosol test cases performed at FNC, the uncertainty of aerosol concentration evaluated by Gaussian error propagation law is less than 1%. The results of uncertainty estimation in the aerosol sampling system will be utilized for the system performance data.

  1. Sample preparation method for ICP-MS measurement of 99Tc in a large amount of environmental samples

    International Nuclear Information System (INIS)

    Kondo, M.; Seki, R.

    2002-01-01

    Sample preparation for measurement of 99 Tc in a large amount of soil and water samples by ICP-MS has been developed using 95m Tc as a yield tracer. This method is based on the conventional method for a small amount of soil samples using incineration, acid digestion, extraction chromatography (TEVA resin) and ICP-MS measurement. Preliminary concentration of Tc has been introduced by co-precipitation with ferric oxide. The matrix materials in a large amount of samples were more sufficiently removed with keeping the high recovery of Tc than previous method. The recovery of Tc was 70-80% for 100 g soil samples and 60-70% for 500 g of soil and 500 L of water samples. The detection limit of this method was evaluated as 0.054 mBq/kg in 500 g soil and 0.032 μBq/L in 500 L water. The determined value of 99 Tc in the IAEA-375 (soil sample collected near the Chernobyl Nuclear Reactor) was 0.25 ± 0.02 Bq/kg. (author)

  2. Axially perpendicular offset Raman scheme for reproducible measurement of housed samples in a noncircular container under variation of container orientation.

    Science.gov (United States)

    Duy, Pham K; Chang, Kyeol; Sriphong, Lawan; Chung, Hoeil

    2015-03-17

    An axially perpendicular offset (APO) scheme that is able to directly acquire reproducible Raman spectra of samples contained in an oval container under variation of container orientation has been demonstrated. This scheme utilized an axially perpendicular geometry between the laser illumination and the Raman photon detection, namely, irradiation through a sidewall of the container and gathering of the Raman photon just beneath the container. In the case of either backscattering or transmission measurements, Raman sampling volumes for an internal sample vary when the orientation of an oval container changes; therefore, the Raman intensities of acquired spectra are inconsistent. The generated Raman photons traverse the same bottom of the container in the APO scheme; the Raman sampling volumes can be relatively more consistent under the same situation. For evaluation, the backscattering, transmission, and APO schemes were simultaneously employed to measure alcohol gel samples contained in an oval polypropylene container at five different orientations and then the accuracies of the determination of the alcohol concentrations were compared. The APO scheme provided the most reproducible spectra, yielding the best accuracy when the axial offset distance was 10 mm. Monte Carlo simulations were performed to study the characteristics of photon propagation in the APO scheme and to explain the origin of the optimal offset distance that was observed. In addition, the utility of the APO scheme was further demonstrated by analyzing samples in a circular glass container.

  3. Accelerated reliability demonstration under competing failure modes

    International Nuclear Information System (INIS)

    Luo, Wei; Zhang, Chun-hua; Chen, Xun; Tan, Yuan-yuan

    2015-01-01

    The conventional reliability demonstration tests are difficult to apply to products with competing failure modes due to the complexity of the lifetime models. This paper develops a testing methodology based on the reliability target allocation for reliability demonstration under competing failure modes at accelerated conditions. The specified reliability at mission time and the risk caused by sampling of the reliability target for products are allocated for each failure mode. The risk caused by degradation measurement fitting of the target for a product involving performance degradation is equally allocated to each degradation failure mode. According to the allocated targets, the accelerated life reliability demonstration test (ALRDT) plans for the failure modes are designed. The accelerated degradation reliability demonstration test plans and the associated ALRDT plans for the degradation failure modes are also designed. Next, the test plan and the decision rules for the products are designed. Additionally, the effects of the discreteness of sample size and accepted number of failures for failure modes on the actual risks caused by sampling for the products are investigated. - Highlights: • Accelerated reliability demonstration under competing failure modes is studied. • The method is based on the reliability target allocation involving the risks. • The test plan for the products is based on the plans for all the failure modes. • Both failure mode and degradation failure modes are considered. • The error of actual risks caused by sampling for the products is small enough

  4. Methodology for sample preparation and size measurement of commercial ZnO nanoparticles

    Directory of Open Access Journals (Sweden)

    Pei-Jia Lu

    2018-04-01

    Full Text Available This study discusses the strategies on sample preparation to acquire images with sufficient quality for size characterization by scanning electron microscope (SEM using two commercial ZnO nanoparticles of different surface properties as a demonstration. The central idea is that micrometer sized aggregates of ZnO in powdered forms need to firstly be broken down to nanosized particles through an appropriate process to generate nanoparticle dispersion before being deposited on a flat surface for SEM observation. Analytical tools such as contact angle, dynamic light scattering and zeta potential have been utilized to optimize the procedure for sample preparation and to check the quality of the results. Meanwhile, measurements of zeta potential values on flat surfaces also provide critical information and save lots of time and efforts in selection of suitable substrate for particles of different properties to be attracted and kept on the surface without further aggregation. This simple, low-cost methodology can be generally applied on size characterization of commercial ZnO nanoparticles with limited information from vendors. Keywords: Zinc oxide, Nanoparticles, Methodology

  5. Sampling artifacts in measurement of elemental and organic carbon: Low-volume sampling in indoor and outdoor environments

    Science.gov (United States)

    Olson, David A.; Norris, Gary A.

    Experiments were completed to determine the extent of artifacts from sampling elemental carbon (EC) and organic carbon (OC) under sample conditions consistent with personal sampling. Two different types of experiments were completed; the first examined possible artifacts from oils used in personal environmental monitor (PEM) impactor plates, and the second examined artifacts from microenvironmental sampling using different sampling media combinations (quartz, Teflon, XAD denuder, and electrostatic precipitator). The effectiveness of front and backup filters was evaluated for most sampling configurations. Mean total carbon concentrations from sampling configurations using impactor oils were not statistically different from the control case (using a sharp cut cyclone). Three microenvironments were tested (kitchen, library, and ambient); carbon concentrations were highest in the kitchen using a front quartz filter (mean OC of 16.4 μg m -3). The lowest front quartz filter concentrations were measured in the library using XAD denuders (mean OC of 3.6 μg m -3). Denuder removal efficiencies (average of 82% for total carbon) were lower compared with previous ambient studies and may indicate that indoor sources influenced denuder efficiency during sample collection. The highest carbon concentrations from backup quartz filters were measured using the Teflon-quartz combination.

  6. Standardized Method for Measuring Collection Efficiency from Wipe-sampling of Trace Explosives.

    Science.gov (United States)

    Verkouteren, Jennifer R; Lawrence, Jeffrey A; Staymates, Matthew E; Sisco, Edward

    2017-04-10

    One of the limiting steps to detecting traces of explosives at screening venues is effective collection of the sample. Wipe-sampling is the most common procedure for collecting traces of explosives, and standardized measurements of collection efficiency are needed to evaluate and optimize sampling protocols. The approach described here is designed to provide this measurement infrastructure, and controls most of the factors known to be relevant to wipe-sampling. Three critical factors (the applied force, travel distance, and travel speed) are controlled using an automated device. Test surfaces are chosen based on similarity to the screening environment, and the wipes can be made from any material considered for use in wipe-sampling. Particle samples of the explosive 1,3,5-trinitroperhydro-1,3,5-triazine (RDX) are applied in a fixed location on the surface using a dry-transfer technique. The particle samples, recently developed to simulate residues made after handling explosives, are produced by inkjet printing of RDX solutions onto polytetrafluoroethylene (PTFE) substrates. Collection efficiency is measured by extracting collected explosive from the wipe, and then related to critical sampling factors and the selection of wipe material and test surface. These measurements are meant to guide the development of sampling protocols at screening venues, where speed and throughput are primary considerations.

  7. Saturation and porosity measurements of different soil samples by gamma ray transmission

    International Nuclear Information System (INIS)

    Akbal, S.; Filiz Baytas, A.

    2000-01-01

    Gamma-ray transmission methods have been used accurately for the study of the properties of soil samples. In this study, the soil samples were collected from various regions of Turkey and a Nal (TI) detector measured the attenuation of strongly collimated monoenergetic gamma beam (from Cs-137) through soil samples. The water saturation and porosity were therefore calculated from the transmission measurements for each soil sample. (authors)

  8. Analytical techniques for measurement of 99Tc in environmental samples

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Three new methods have been developed for measuring 99 Tc in environmental samples. The most sensitive method is isotope dilution mass spectrometry, which allows measurement of about 1 x 10 -12 grams of 99 Tc. Results on analysis of five samples by this method compare very well with values obtained by a second independent method, which involves counting of beta particles from 99 Tc and internal conversion electrons from /sup 97m/Tc. A third method involving electrothermal atomic absorption has also been developed. Although this method is not as sensitive as the first two techniques, the cost per analysis is expected to be considerably less for certain types of samples

  9. Particle identification by means of fine sampling dE/dX measurements

    Energy Technology Data Exchange (ETDEWEB)

    Imanishi, A; Ishii, T; Ohshima, T; Okuno, H; Shiino, K [Tokyo Univ., Tanashi (Japan). Inst. for Nuclear Study; Naito, F [Tokyo Univ. of Agriculture and Technology, Koganei (Japan). Faculty of Technology; Matsuda, T [Osaka Univ., Toyonaka (Japan). Faculty of Engineering Science

    1983-04-01

    Identification of relativistic charged particles by means of fine sampling d E/d X measurements with a longitudinal drift chamber has been studied. Using a fast-sampling ADC (25 MHz), dE/dX was measured in a 1.4 mm gas thickness over an electron drift space of 51 mm. For the simulated 1 m long tracks of pions and electrons of 500 MeV/c, a particle separation of 10sigma - 12sigma has been obtained, where sigma is the r.m.s. resolution of the dE/dX measurement. This result with fine sampling is better by a factor of 1.7 compared to the dE/dX measurement, with 21 mm sampling thickness. Further improvement achievable by reducing the correlation between neighbouring samples and simplification of electronics by use of the delta-ray clipping method are also discussed.

  10. Micro/Nano-scale Strain Distribution Measurement from Sampling Moiré Fringes.

    Science.gov (United States)

    Wang, Qinghua; Ri, Shien; Tsuda, Hiroshi

    2017-05-23

    This work describes the measurement procedure and principles of a sampling moiré technique for full-field micro/nano-scale deformation measurements. The developed technique can be performed in two ways: using the reconstructed multiplication moiré method or the spatial phase-shifting sampling moiré method. When the specimen grid pitch is around 2 pixels, 2-pixel sampling moiré fringes are generated to reconstruct a multiplication moiré pattern for a deformation measurement. Both the displacement and strain sensitivities are twice as high as in the traditional scanning moiré method in the same wide field of view. When the specimen grid pitch is around or greater than 3 pixels, multi-pixel sampling moiré fringes are generated, and a spatial phase-shifting technique is combined for a full-field deformation measurement. The strain measurement accuracy is significantly improved, and automatic batch measurement is easily achievable. Both methods can measure the two-dimensional (2D) strain distributions from a single-shot grid image without rotating the specimen or scanning lines, as in traditional moiré techniques. As examples, the 2D displacement and strain distributions, including the shear strains of two carbon fiber-reinforced plastic specimens, were measured in three-point bending tests. The proposed technique is expected to play an important role in the non-destructive quantitative evaluations of mechanical properties, crack occurrences, and residual stresses of a variety of materials.

  11. Measurement of curium in marine samples

    Science.gov (United States)

    Schneider, D. L.; Livingston, H. D.

    1984-06-01

    Measurement of environmentally small but detectable amounts of curium requires reliable, accureate, and sensitive analytical methods. The radiochemical separation developed at Woods Hole is briefly reviewed with specific reference to radiochemical interferences in the alpha spectrometric measurement of curium nuclides and to the relative amounts of interferences expected in different oceanic regimes and sample types. Detection limits for 242 Cm and 244 Cm are ultimately limited by their presence in the 243Am used as curium yield monitor. Environmental standard reference materials are evaluated with regard to curium. The marine literature is reviewed and curium measurements are discussed in relation to their source of introduction to the environment. Sources include ocean dumping of low-level radioactive wastes and discharges from nuclear fuel reporcessing activities, In particular, the question of a detectable presence of 244Cm in global fallout from nuclear weapons testing is addressed and shown to be essentially negligible. Analyses of Scottish coastal sedimantes show traces of 242Cm and 244Cm activity which are believed to originate from transport from sources in the Irish Sea.

  12. National comparison on volume sample activity measurement methods

    International Nuclear Information System (INIS)

    Sahagia, M.; Grigorescu, E.L.; Popescu, C.; Razdolescu, C.

    1992-01-01

    A national comparison on volume sample activity measurements methods may be regarded as a step toward accomplishing the traceability of the environmental and food chain activity measurements to national standards. For this purpose, the Radionuclide Metrology Laboratory has distributed 137 Cs and 134 Cs water-equivalent solid standard sources to 24 laboratories having responsibilities in this matter. Every laboratory has to measure the activity of the received source(s) by using its own standards, equipment and methods and report the obtained results to the organizer. The 'measured activities' will be compared with the 'true activities'. A final report will be issued, which plans to evaluate the national level of precision of such measurements and give some suggestions for improvement. (Author)

  13. Performance Demonstration Program Plan for RCRA Constituent Analysis of Solidified Wastes

    International Nuclear Information System (INIS)

    2006-01-01

    The Performance Demonstration Program (PDP) for Resource Conservation and Recovery Act (RCRA) constituents distributes test samples for analysis of volatile organic compounds (VOCs), semivolatile organic compounds (SVOCs), and metals in solid matrices. Each distribution of test samples is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements performed for transuranic (TRU) waste characterization. The primary documents governing the conduct of the PDP are the Quality Assurance Program Document (QAPD; DOE/CBFO-94-1012) and the Waste Isolation Pilot Plant (WIPP) Waste Analysis Plan (WAP) contained in the Hazardous Waste Facility Permit (NM4890139088-TSDF) issued by the New Mexico Environment Department. The WAP requires participation in the PDP; the PDP must comply with the QAPD and the WAP. This plan implements the general requirements of the QAPD and the applicable requirements of the WAP for the RCRA PDP. Participating laboratories demonstrate acceptable performance by successfully analyzing single-blind performance evaluation samples (subsequently referred to as PDP samples) according to the criteria established in this plan. PDP samples are used as an independent means to assess laboratory performance regarding compliance with the WAP quality assurance objectives (QAOs). The concentrations of analytes in the PDP samples address levels of regulatory concern and encompass the range of concentrations anticipated in waste characterization samples. The WIPP requires analyses of homogeneous solid wastes to demonstrate compliance with regulatory requirements. These analyses must be performed by laboratories that demonstrate acceptable performance in this PDP. These analyses are referred to as WIPP analyses, and the samples on which they are performed are referred to as WIPP samples. Participating laboratories must analyze PDP samples using the same procedures used for WIPP samples.

  14. Permeability Measurements of Rock Samples from Conduit Drilling at Unzen Volcano, Japan

    Science.gov (United States)

    Watanabe, T.; Shimizu, Y.; Noguchi, S.; Nakada, S.

    2006-12-01

    The last eruption of Unzen Volcano (1990-1995) was effusive to form lava domes, though magmas at depths are estimated to have contained volatile materials enough to cause explosive eruptions [e.g., Sato et al., 1995]. Most of volatile materials should have escaped from ascending magmas. The escape of gas is controlled by permeability of magmas and country rocks. Unzen Scientific Drilling Project sampled both the latest conduit and its country rock (USDP-4). In order to understand degassing processes, we have measured the permeability of these rock samples. Four cube samples with edges of 25 mm were cut from USDP-4 cores C1, C12 (country rock), C13 and C14 (conduit). Sample C1 is considered as Old Unzen Lava, and Sample C12 volcanic breccia. The transient pulse method was employed to measure the permeability. It applies a step of the fluid pressure difference across a specimen, and measures the decay rate of the fluid pressure difference. This method can be applied to samples with very low permeability, since it determines the permeability without measuring the fluid flux. Nitrogen gas was used as a pore fluid. Our permeametry system is built in a pressure vessel, and the confining pressure and the pore fluid pressure can be controlled independently. The temperature of the measurement system is kept constant within 0.1 degree. The temperature control and the background leak rate limit the measurable permeability to be higher than 10^{-20} m2. Measurements were first conducted under the atmospheric pressure. The permeability in a rock sample varies with the direction by a factor less than 5. Sample C1 has the lowest permeability (10^{-19} m2), and Sample C12 the highest value (10^{-17 m2). The permeability of C13 and C14 is of the order of 10^{- 18} m2. Though only a trace of vesicles can be seen in conduit samples, the interconnection is still maintained. The pressure dependence of the permeability is now investigated up to 50 MPa. The permeability of C13 and C14

  15. Spatiotemporal image correlation spectroscopy measurements of flow demonstrated in microfluidic channels

    Science.gov (United States)

    Rossow, Molly; Mantulin, William W.; Gratton, Enrico

    2009-03-01

    Accurate blood flow measurements during surgery can improve an operation's chance of success. We developed near-infrared spatio-temporal image spectroscopy (NIR-STICS), which has the potential to make blood flow measurements that are difficult to accomplish with existing methods. Specifically, we propose the technique and we show feasibility on phantom measurements. NIR-STICS has the potential of measuring the fluid velocity in small blood vessels (less than 1 mm in diameter) and of creating a map of blood flow rates over an area of approximately 1 cm2. NIR-STICS employs near-infrared spectroscopy to probe inside blood vessel walls and spatiotemporal image correlation spectroscopy to directly-without the use of a model-extract fluid velocity from the fluctuations within an image. We present computer simulations and experiments on a phantom system that demonstrate the effectiveness of NIR-STICS.

  16. Compressed sampling for boundary measurements in three-dimensional electrical impedance tomography

    International Nuclear Information System (INIS)

    Javaherian, Ashkan; Soleimani, Manuchehr

    2013-01-01

    Electrical impedance tomography (EIT) utilizes electrodes on a medium's surface to produce measured data from which the conductivity distribution inside the medium is estimated. For the cases that relocation of electrodes is impractical or no a priori assumptions can be made to optimize the electrodes placement, a large number of electrodes may be needed to cover all possible imaging volume. This may occur in dynamically varying conductivity distribution in 3D EIT. Three-dimensional EIT then requires inverting very large linear systems to calculate the conductivity field, which causes significant problems regarding storage space and reconstruction time in addition to that data acquisition for a large number of electrodes will reduce the achievable frame rate, which is considered as major advantage of EIT imaging. This study proposes an idea to reduce the reconstruction complexity based on the well-known compressed sampling theory. By applying the so-called model-based CoSaMP algorithm to large size data collected by a 256 channel system, the size of forward operator and data acquisition time is reduced to those of a 32 channel system, while accuracy of reconstruction is significantly improved. The results demonstrate great capability of compressed sampling for overriding the challenges arising in 3D EIT. (paper)

  17. Demonstration of an automated electromanometer for measurement of solution volume in accountability vessels

    International Nuclear Information System (INIS)

    Suda, S.; Keisch, B.; Hayashi, M.; Onuma, T.; Fukuari, Y.

    1981-09-01

    A system for measuring the liquid volume in input and plutonium product accountability vessels, based upon a desktop-computer-controlled electromanometer, was installed at the Tokai-Mura reprocessing plant. In-tank temperatures, pressure measurements relating to volume and density, and load-cell weights are measured cyclically and recorded. The system feasibility was demonstrated through a series of tests including vessel calibration and the effects of thermal expansion, and through use during thirteen months of on-line plant operation. The value to the operator of the recording, display, replay, data handling, and report generation features of the system was demonstrated as was the enhanced precision of the electromanometer as compared to the conventional water-filled manometer system. The automated electromanometer system consists of a pneumatic scanner, a precision electromanometer, electronic scanner, a digital voltmeter, and a desktop computer with disc and tape mass storage, cathode-ray tube (CRT) graphics display, and printer output. The desktop computer is used to control the pneumatic and electronic scanners and the digital voltmeter and to log in the measurement data

  18. BRDF of Salt Pan Regolith Samples

    Science.gov (United States)

    Georgiev, Georgi T.; Gatebe, Charles K.; Butler, James J.; King, Michael D.

    2008-01-01

    Laboratory Bi-directional Reflectance Distribution Function (BRDF) measurements of salt pan regolith samples are presented in this study in an effort to understand the role of spatial and spectral variability of the natural biome. The samples were obtained from Etosha Pan, Namibia (19.20 deg S, 15.93 deg E, alt. 1100 m). It is shown how the BRDF depends on the measurement geometry - incident and scatter angles and on the sample particle sizes. As a demonstration of the application of the results, airborne BRDF measurements acquires with NASA's Cloud Absorption Radiometer (CAR) over the same general site where the regolith samples were collected are compared with the laboratory results. Good agreement between laboratory measured and field measured BRDF is reported.

  19. Developing a research and practice tool to measure walkability: a demonstration project.

    Science.gov (United States)

    Giles-Corti, Billie; Macaulay, Gus; Middleton, Nick; Boruff, Bryan; Bull, Fiona; Butterworth, Iain; Badland, Hannah; Mavoa, Suzanne; Roberts, Rebecca; Christian, Hayley

    2014-12-01

    Growing evidence shows that higher-density, mixed-use, pedestrian-friendly neighbourhoods encourage active transport, including transport-related walking. Despite widespread recognition of the benefits of creating more walkable neighbourhoods, there remains a gap between the rhetoric of the need for walkability and the creation of walkable neighbourhoods. Moreover, there is little objective data to benchmark the walkability of neighbourhoods within and between Australian cities in order to monitor planning and design intervention progress and to assess built environment and urban policy interventions required to achieve increased walkability. This paper describes a demonstration project that aimed to develop, trial and validate a 'Walkability Index Tool' that could be used by policy makers and practitioners to assess the walkability of local areas; or by researchers to access geospatial data assessing walkability. The overall aim of the project was to develop an automated geospatial tool capable of creating walkability indices for neighbourhoods at user-specified scales. The tool is based on open-source software architecture, within the Australian Urban Research Infrastructure Network (AURIN) framework, and incorporates key sub-component spatial measures of walkability (street connectivity, density and land use mix). Using state-based data, we demonstrated it was possible to create an automated walkability index. However, due to the lack of availability of consistent of national data measuring land use mix, at this stage it has not been possible to create a national walkability measure. The next stage of the project is to increase useability of the tool within the AURIN portal and to explore options for alternative spatial data sources that will enable the development of a valid national walkability index. AURIN's open-source Walkability Index Tool is a first step in demonstrating the potential benefit of a tool that could measure walkability across Australia. It

  20. Environmental gamma-ray measurements using in situ and core sampling techniques

    International Nuclear Information System (INIS)

    Dickson, H.W.; Kerr, G.D.; Perdue, P.T.; Abdullah, S.A.

    1976-01-01

    Dose rates from natural radionuclides and 137 Cs in soils of the Oak Ridge area have been determined from in situ and core sample measurements. In situ γ-ray measurements were made with a transportable spectrometer. A tape of spectral data and a soil core sample from each site were returned to ORNL for further analysis. Information on soil composition, density and moisture content and on the distribution of cesium in the soil was obtained from the core samples. In situ spectra were analyzed by a computer program which identified and assigned energies to peaks, integrated the areas under the peaks, and calculated radionuclide concentrations based on a uniform distribution in the soil. The assumption of a uniform distribution was adequate only for natural radionuclides, but simple corrections can be made to the computer calculations for man-made radionuclides distributed on the surface or exponentially in the soil. For 137 Cs a correction was used based on an exponential function fitted to the distribution measured in core samples. At typical sites in Oak Ridge, the dose rate determined from these measurements was about 5 μrad/hr. (author)

  1. Manipulation of Samples at Extreme Temperatures for Fast in-situ Synchrotron Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Richard [Materials Development, Inc., Arlington Heights, IL (United States)

    2016-04-22

    An aerodynamic sample levitation system with laser beam heating was integrated with the APS beamlines 6 ID-D, 11 ID-C and 20 BM-B. The new capability enables in-situ measurements of structure and XANES at extreme temperatures (300-3500 °C) and in conditions that completely avoid contact with container surfaces. In addition to maintaining a high degree of sample purity, the use of aerodynamic levitation enables deep supercooling and greatly enhanced glass formation from a wide variety of melts and liquids. Development and integration of controlled extreme sample environments and new measurement techniques is an important aspect of beamline operations and user support. Processing and solidifying liquids is a critical value-adding step in manufacturing semiconductors, optical materials, metals and in the operation of many energy conversion devices. Understanding structural evolution is of fundamental importance in condensed materials, geology, and biology. The new capability provides unique possibilities for materials research and helps to develop and maintain a competitive materials manufacturing and energy utilization industry. Test samples were used to demonstrate key features of the capability including experiments on hot crystalline materials, liquids at temperatures from about 500 to 3500 °C. The use of controlled atmospheres using redox gas mixtures enabled in-situ changes in the oxidation states of cations in melts. Significant innovations in this work were: (i) Use of redox gas mixtures to adjust the oxidation state of cations in-situ (ii) Operation with a fully enclosed system suitable for work with nuclear fuel materials (iii) Making high quality high energy in-situ x-ray diffraction measurements (iv) Making high quality in-situ XANES measurements (v) Publishing high impact results (vi) Developing independent funding for the research on nuclear materials This SBIR project work led to a commercial instrument product for the niche market of processing and

  2. Autonomous spatially adaptive sampling in experiments based on curvature, statistical error and sample spacing with applications in LDA measurements

    Science.gov (United States)

    Theunissen, Raf; Kadosh, Jesse S.; Allen, Christian B.

    2015-06-01

    Spatially varying signals are typically sampled by collecting uniformly spaced samples irrespective of the signal content. For signals with inhomogeneous information content, this leads to unnecessarily dense sampling in regions of low interest or insufficient sample density at important features, or both. A new adaptive sampling technique is presented directing sample collection in proportion to local information content, capturing adequately the short-period features while sparsely sampling less dynamic regions. The proposed method incorporates a data-adapted sampling strategy on the basis of signal curvature, sample space-filling, variable experimental uncertainty and iterative improvement. Numerical assessment has indicated a reduction in the number of samples required to achieve a predefined uncertainty level overall while improving local accuracy for important features. The potential of the proposed method has been further demonstrated on the basis of Laser Doppler Anemometry experiments examining the wake behind a NACA0012 airfoil and the boundary layer characterisation of a flat plate.

  3. Accurate EPR radiosensitivity calibration using small sample masses

    Science.gov (United States)

    Hayes, R. B.; Haskell, E. H.; Barrus, J. K.; Kenner, G. H.; Romanyukha, A. A.

    2000-03-01

    We demonstrate a procedure in retrospective EPR dosimetry which allows for virtually nondestructive sample evaluation in terms of sample irradiations. For this procedure to work, it is shown that corrections must be made for cavity response characteristics when using variable mass samples. Likewise, methods are employed to correct for empty tube signals, sample anisotropy and frequency drift while considering the effects of dose distribution optimization. A demonstration of the method's utility is given by comparing sample portions evaluated using both the described methodology and standard full sample additive dose techniques. The samples used in this study are tooth enamel from teeth removed during routine dental care. We show that by making all the recommended corrections, very small masses can be both accurately measured and correlated with measurements of other samples. Some issues relating to dose distribution optimization are also addressed.

  4. Accurate EPR radiosensitivity calibration using small sample masses

    International Nuclear Information System (INIS)

    Hayes, R.B.; Haskell, E.H.; Barrus, J.K.; Kenner, G.H.; Romanyukha, A.A.

    2000-01-01

    We demonstrate a procedure in retrospective EPR dosimetry which allows for virtually nondestructive sample evaluation in terms of sample irradiations. For this procedure to work, it is shown that corrections must be made for cavity response characteristics when using variable mass samples. Likewise, methods are employed to correct for empty tube signals, sample anisotropy and frequency drift while considering the effects of dose distribution optimization. A demonstration of the method's utility is given by comparing sample portions evaluated using both the described methodology and standard full sample additive dose techniques. The samples used in this study are tooth enamel from teeth removed during routine dental care. We show that by making all the recommended corrections, very small masses can be both accurately measured and correlated with measurements of other samples. Some issues relating to dose distribution optimization are also addressed

  5. Noise in NC-AFM measurements with significant tip–sample interaction

    Directory of Open Access Journals (Sweden)

    Jannis Lübbe

    2016-12-01

    Full Text Available The frequency shift noise in non-contact atomic force microscopy (NC-AFM imaging and spectroscopy consists of thermal noise and detection system noise with an additional contribution from amplitude noise if there are significant tip–sample interactions. The total noise power spectral density DΔf(fm is, however, not just the sum of these noise contributions. Instead its magnitude and spectral characteristics are determined by the strongly non-linear tip–sample interaction, by the coupling between the amplitude and tip–sample distance control loops of the NC-AFM system as well as by the characteristics of the phase locked loop (PLL detector used for frequency demodulation. Here, we measure DΔf(fm for various NC-AFM parameter settings representing realistic measurement conditions and compare experimental data to simulations based on a model of the NC-AFM system that includes the tip–sample interaction. The good agreement between predicted and measured noise spectra confirms that the model covers the relevant noise contributions and interactions. Results yield a general understanding of noise generation and propagation in the NC-AFM and provide a quantitative prediction of noise for given experimental parameters. We derive strategies for noise-optimised imaging and spectroscopy and outline a full optimisation procedure for the instrumentation and control loops.

  6. Improved sample preparation and counting techniques for enhanced tritium measurement sensitivity

    Science.gov (United States)

    Moran, J.; Aalseth, C.; Bailey, V. L.; Mace, E. K.; Overman, C.; Seifert, A.; Wilcox Freeburg, E. D.

    2015-12-01

    Tritium (T) measurements offer insight to a wealth of environmental applications including hydrologic tracking, discerning ocean circulation patterns, and aging ice formations. However, the relatively short half-life of T (12.3 years) limits its effective age dating range. Compounding this limitation is the decrease in atmospheric T content by over two orders of magnitude (from 1000-2000 TU in 1962 to testing in the 1960's. We are developing sample preparation methods coupled to direct counting of T via ultra-low background proportional counters which, when combined, offer improved T measurement sensitivity (~4.5 mmoles of H2 equivalent) and will help expand the application of T age dating to smaller sample sizes linked to persistent environmental questions despite the limitations above. For instance, this approach can be used to T date ~ 2.2 mmoles of CH4 collected from sample-limited systems including microbial communities, soils, or subsurface aquifers and can be combined with radiocarbon dating to distinguish the methane's formation age from C age in a system. This approach can also expand investigations into soil organic C where the improved sensitivity will permit resolution of soil C into more descriptive fractions and provide direct assessments of the stability of specific classes of organic matter in soils environments. We are employing a multiple step sample preparation system whereby organic samples are first combusted with resulting CO2 and H2O being used as a feedstock to synthesize CH4. This CH4 is mixed with Ar and loaded directly into an ultra-low background proportional counter for measurement of T β decay in a shallow underground laboratory. Analysis of water samples requires only the addition of geologic CO2 feedstock with the sample for methane synthesis. The chemical nature of the preparation techniques enable high sample throughput with only the final measurement requiring T decay with total sample analysis time ranging from 2 -5 weeks

  7. Performance Demonstration Program Plan for Nondestructive Assay for the TRU Waste Characterization Program. Revision 1

    International Nuclear Information System (INIS)

    1997-01-01

    The Performance Demonstration Program (PDP) for Nondestructive Assay (NDA) consists of a series of tests conducted on a regular frequency to evaluate the capability for nondestructive assay of transuranic (TRU) waste throughout the Department of Energy (DOE) complex. Each test is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements performed with TRU waste characterization systems. Measurement facility performance will be demonstrated by the successful analysis of blind audit samples according to the criteria set by this Program Plan. Intercomparison between measurement groups of the DOE complex will be achieved by comparing the results of measurements on similar or identical blind samples reported by the different measurement facilities. Blind audit samples (hereinafter referred to as PDP samples) will be used as an independent means to assess the performance of measurement groups regarding compliance with established Quality Assurance Objectives (QAOs). As defined for this program, a PDP sample consists of a 55-gallon matrix drum emplaced with radioactive standards and fabricated matrix inserts. These PDP sample components, once manufactured, will be secured and stored at each participating measurement facility designated and authorized by Carlsbad Area Office (CAO) under secure conditions to protect them from loss, tampering, or accidental damage

  8. DGT Passive Sampling for Quantitative in Situ Measurements of Compounds from Household and Personal Care Products in Waters.

    Science.gov (United States)

    Chen, Wei; Li, Yanying; Chen, Chang-Er; Sweetman, Andrew J; Zhang, Hao; Jones, Kevin C

    2017-11-21

    Widespread use of organic chemicals in household and personal care products (HPCPs) and their discharge into aquatic systems means reliable, robust techniques to monitor environmental concentrations are needed. The passive sampling approach of diffusive gradients in thin-films (DGT) is developed here and demonstrated to provide in situ quantitative and time-weighted average (TWA) measurement of these chemicals in waters. The novel technique is developed for HPCPs, including preservatives, antioxidants and disinfectants, by evaluating the performance of different binding agents. Ultrasonic extraction of binding gels in acetonitrile gave good and consistent recoveries for all test chemicals. Uptake by DGT with HLB (hydrophilic-lipophilic-balanced) as the binding agent was relatively independent of pH (3.5-9.5), ionic strength (0.001-0.1 M) and dissolved organic matter (0-20 mg L -1 ), making it suitable for applications across a wide range of environments. Deployment time and diffusion layer thickness dependence experiments confirmed DGT accumulated chemicals masses are consistent with theoretical predictions. The technique was further tested and applied in the influent and effluent of a wastewater treatment plant. Results were compared with conventional grab-sampling and 24-h-composited samples from autosamplers. DGT provided TWA concentrations over up to 18 days deployment, with minimal effects from biofouling or the diffusive boundary layer. The field application demonstrated advantages of the DGT technique: it gives in situ analyte preconcentration in a simple matrix, with more quantitative measurement of the HPCP analytes.

  9. Measurements of {sup 55}Fe activity in activated steel samples with GEMPix

    Energy Technology Data Exchange (ETDEWEB)

    Curioni, A. [CERN, 1211 Geneva 23 (Switzerland); Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Dinar, N. [CERN, 1211 Geneva 23 (Switzerland); Université de Paris VII, 5 rue Thomas-Mann, 75013 Paris (France); La Torre, F.P. [CERN, 1211 Geneva 23 (Switzerland); Leidner, J., E-mail: johannes.leidner@cern.ch [CERN, 1211 Geneva 23 (Switzerland); RWTH Aachen, Templergraben 55, 52056 Aachen (Germany); Murtas, F. [CERN, 1211 Geneva 23 (Switzerland); INFN-LNF, Via E. Fermi 40, 00044 Frascati (Italy); Puddu, S.; Silari, M. [CERN, 1211 Geneva 23 (Switzerland)

    2017-03-21

    In this paper we present a novel method, based on the recently developed GEMPix detector, to measure the {sup 55}Fe content in samples of metallic material activated during operation of CERN accelerators and experimental facilities. The GEMPix, a gas detector with highly pixelated read-out, has been obtained by coupling a triple Gas Electron Multiplier (GEM) to a quad Timepix ASIC. Sample preparation, measurements performed on 45 samples and data analysis are described. The calibration factor (counts per second per unit specific activity) has been obtained via measurements of the {sup 55}Fe activity determined by radiochemical analysis of the same samples. Detection limit and sensitivity to the current Swiss exemption limit are calculated. Comparison with radiochemical analysis shows inconsistency for the sensitivity for only two samples, most likely due to underestimated uncertainties of the GEMPix analysis. An operative test phase of this technique is already planned at CERN.

  10. passive and active measurements for some ceramic samples

    International Nuclear Information System (INIS)

    Hassan, M.F.; Said, S.A.; Ali, M.A.; Szegedi, S.

    2004-01-01

    passive measurements for an imported natural ore (zirconium silicate) used in ceramic industries were carried out to identify its radioactivity . this work was done for ceramic quality control purposes. accurate gamma spectrometers with 30% and 70% detector efficiencies were used in the measurements. the 235 U, 238 U and 232 Th radioactivity were determined . for the sake of comparison already manufactured different ceramic samples were investigated applying fast neutrons activation analysis (FNAA) and X-Ray florescence (XRF) techniques. the obtained results were discussed with the tabulated international radioactivity levels for building materials

  11. Calorimeters for Precision Power Dissipation Measurements on Controlled-Temperature Superconducting Radiofrequency Samples

    International Nuclear Information System (INIS)

    Xiao, Binping P.; Kelley, Michael J.; Reece, Charles E.; Phillips, H. L.

    2012-01-01

    Two calorimeters, with stainless steel and Cu as the thermal path material for high precision and high power versions, respectively, have been designed and commissioned for the surface impedance characterization (SIC) system at Jefferson Lab to provide low temperature control and measurement for CW power up to 22 W on a 5 cm dia. disk sample which is thermally isolated from the RF portion of the system. A power compensation method has been developed to measure the RF induced power on the sample. Simulation and experimental results show that with these two calorimeters, the whole thermal range of interest for superconducting radiofrequency (SRF) materials has been covered. The power measurement error in the interested power range is within 1.2% and 2.7% for the high precision and high power versions, respectively. Temperature distributions on the sample surface for both versions have been simulated and the accuracy of sample temperature measurements have been analysed. Both versions have the ability to accept bulk superconductors and thin film superconducting samples with a variety of substrate materials such as Al, Al 2 O 3 , Cu, MgO, Nb and Si

  12. Rapid methods for measuring radionuclides in food and environmental samples

    International Nuclear Information System (INIS)

    Perkins, Richard W.

    1995-01-01

    The application of ICP/mass spectrometry for the isotopic analysis of environmental samples, the use of drum assayers for measuring radionuclides in food and a rapid procedure for the measurement of the transuranic elements and thorium, performed at the Pacific Northwest Laboratory are discussed

  13. The measurement of radioactive microspheres in biological samples

    International Nuclear Information System (INIS)

    Mernagh, J.R.; Spiers, E.W.; Adiseshiah, M.

    1976-01-01

    Measurements of the distribution of radioactive microspheres are used in investigations of regional coronary blood flow, but the size and shape of the heart varies for different test animals, and the organ is frequently divided into smaller pieces for studies of regional perfusion. Errors are introduced by variations in the distribution of the radioactive source and the amount of Compton scatter in different samples. A technique has therefore been developed to allow the counting of these tissue samples in their original form, and correction factors have been derived to inter-relate the various counting geometries thus encountered. Dogs were injected with microspheres labelled with 141 Ce, 51 Cr or 85 Sr. The tissue samples did not require remodelling to fit a standard container, and allowance was made for the inhomogeneous distribution in the blood samples. The activities in the centrifuged blood samples were correlated with those from the tissue samples by a calibration procedure involving comparisons of the counts from samples of microspheres embedded in sachets of gelatine, and similar samples mixed with blood and then centrifuged. The calibration data have indicated that 51 Cr behaves anomalously, and its use as a label for microspheres may introduce unwarranted errors. A plane cylindrical 10 x 20 cm NaI detector was used, and a 'worst case' correction of 20% was found to be necessary for geometry effects. The accuracy of this method of correlating different geometries was tested by remodelling the same tissue sample into different sizes and comparing the results, and the validity of the technique was supported by agreement of the final results with previously published data. (U.K.)

  14. Measurement and structural invariance of the US version of the Birth Satisfaction Scale-Revised (BSS-R) in a large sample.

    Science.gov (United States)

    Martin, Colin R; Hollins Martin, Caroline J; Burduli, Ekaterina; Barbosa-Leiker, Celestina; Donovan-Batson, Colleen; Fleming, Susan E

    2017-08-01

    The 10-item Birth Satisfaction Scale-Revised (BSS-R) is being increasingly used internationally. The use of the measure and the concept has gathered traction in the United States following the development of a US version of the tool. A limitation of previous studies of the measurement characteristics of the BSS-R is modest sample size. Unplanned pregnancy is recognised as being associated with a range of negative birth outcomes, but the relationship to birth satisfaction has received little attention, despite the importance of birth satisfaction to a range of postnatal outcomes. The current investigation sought to evaluate the measurement characteristics of the BSS-R in a large postpartum sample. Multiple Groups Confirmatory Factor Analysis (MGCFA) was used to evaluate a series of measurement and structural models of the BSS-R to evaluate fundamental invariance characteristics using planned/unplanned pregnancy status to differentiate groups. Complete data from N=2116 women revealed that the US version of the BSS-R offers an excellent fit to data and demonstrates full measurement and structural invariance. Little difference was observed between women on the basis of planned/unplanned pregnancy stratification on measures of birth satisfaction. The established relationship between unplanned pregnancy and negative perinatal outcomes was not found to extend to birth satisfaction in the current study. The BSS-R demonstrated exemplary measurement and structural invariance characteristics. The current study strongly supports the use of the US version of the BSS-R to compare birth satisfaction across different groups of women with theoretical and measurement confidence. Copyright © 2016 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  15. Sampling strategies to measure the prevalence of common recurrent infections in longitudinal studies

    Directory of Open Access Journals (Sweden)

    Luby Stephen P

    2010-08-01

    Full Text Available Abstract Background Measuring recurrent infections such as diarrhoea or respiratory infections in epidemiological studies is a methodological challenge. Problems in measuring the incidence of recurrent infections include the episode definition, recall error, and the logistics of close follow up. Longitudinal prevalence (LP, the proportion-of-time-ill estimated by repeated prevalence measurements, is an alternative measure to incidence of recurrent infections. In contrast to incidence which usually requires continuous sampling, LP can be measured at intervals. This study explored how many more participants are needed for infrequent sampling to achieve the same study power as frequent sampling. Methods We developed a set of four empirical simulation models representing low and high risk settings with short or long episode durations. The model was used to evaluate different sampling strategies with different assumptions on recall period and recall error. Results The model identified three major factors that influence sampling strategies: (1 the clustering of episodes in individuals; (2 the duration of episodes; (3 the positive correlation between an individual's disease incidence and episode duration. Intermittent sampling (e.g. 12 times per year often requires only a slightly larger sample size compared to continuous sampling, especially in cluster-randomized trials. The collection of period prevalence data can lead to highly biased effect estimates if the exposure variable is associated with episode duration. To maximize study power, recall periods of 3 to 7 days may be preferable over shorter periods, even if this leads to inaccuracy in the prevalence estimates. Conclusion Choosing the optimal approach to measure recurrent infections in epidemiological studies depends on the setting, the study objectives, study design and budget constraints. Sampling at intervals can contribute to making epidemiological studies and trials more efficient, valid

  16. Stability of measures from children's interviews: the effects of time, sample length, and topic.

    Science.gov (United States)

    Heilmann, John; DeBrock, Lindsay; Riley-Tillman, T Chris

    2013-08-01

    The purpose of this study was to examine the reliability of, and sources of variability in, language measures from interviews collected from young school-age children. Two 10-min interviews were collected from 20 at-risk kindergarten children by an examiner using a standardized set of questions. Test-retest reliability coefficients were calculated for 8 language measures. Generalizability theory (G-theory) analyses were completed to document the variability introduced into the measures from the child, session, sample length, and topic. Significant and strong reliability correlation coefficients were observed for most of the language sample measures. The G-theory analyses revealed that most of the variance in the language measures was attributed to the child. Session, sample length, and topic accounted for negligible amounts of variance in most of the language measures. Measures from interviews were reliable across sessions, and the sample length and topic did not have a substantial impact on the reliability of the language measures. Implications regarding the clinical feasibility of language sample analysis for assessment and progress monitoring are discussed.

  17. Measurement of stable isotope ratio of organic carbon in water samples

    International Nuclear Information System (INIS)

    Fujii, Toshihiro; Otsuki, Akira

    1977-01-01

    A new method for the measurement of stable isotope ratios was investigated and applied to organic carbon's isotope ratio measurements in water samples. A few river water samples from Tsuchiura city were tested. After the wet oxidation of organic carbons to carbon dioxide in a sealed ampoule, the isotope ratios were determined with the gas chromatograph-quadrupole mass spectrometer combined with a total organic carbon analyser, under the dynamic conditions. The GC-MS had been equipped with the multiple ion detector-digital integrator system. The ion intensities at m/e 44 and 45 were simultaneously measured at a switching rate of 1 ms. The measurements with carbon dioxide acquired from sodium carbonate (53 μg) gave the isotope ratios with the variation coefficient of 0.62%. However, the variation coefficients obtained from organic carbons in natural water samples were 2 to 3 times as high as that from sodium carbonate. This method is simple and rapid and may be applied to various fields especially in biology and medicine. (auth.)

  18. Test Plan for the overburden removal demonstration

    International Nuclear Information System (INIS)

    Rice, P.; Thompson, D.; Winberg, M.; Skaggs, J.

    1993-06-01

    The removal of soil overburdens from contaminated pits and trenches involves using equipment that will remove a small layer of soil from 3 to 6 in. at any time. As a layer of soil is removed, overburden characterization techniques perform surveys to a depth that exceeds each overburden removal layer to ensure that the removed soil will be free of contamination. It is generally expected that no contamination will be found in the soil overburden, which was brought in after the waste was put in place. It is anticipated that some containers in the waste zone have lost their integrity, and the waste leakage from those containers has migrated by gravity downward into the waste zone. To maintain a safe work environment, this method of overburden removal should allow safe preparation of a pit or trench for final remediation. To demonstrate the soil overburden techniques, the Buried Waste Integrated Demonstration Program has contracted vendor services to provide equipment and techniques demonstrating soil overburden removal technology. The demonstration will include tests that will evaluate equipment performance and techniques for removal of overburden soil, control of contamination spread, and dust control. To evaluate the performance of these techniques, air particulate samples, physical measurements of the excavation soil cuts, maneuverability measurements, and time versus volume (rate) of soil removal data will be collected during removal operations. To provide a medium for sample evaluation, the overburden will be spiked at specific locations and depths with rare earth tracers. This test plan will be describe the objectives of the demonstration, data quality objectives, methods to be used to operate the equipment and use the techniques in the test area, and methods to be used in collecting data during the demonstration

  19. An instrumentation for control and measurement of activated mineral samples

    International Nuclear Information System (INIS)

    Skaarup, P.

    1976-01-01

    A description is given of an instrumentation for control of a pneumatic tube system used to transport mineral samples for activation in a reactor and from there to a detector arrangement. A possible content of uranium in the samples can be seen from the radiation measured. The instrumentation includes a PDP-11 computer and a CAMAC crate

  20. Measuring environmental change in forest ecosystems by repeated soil sampling: a North American perspective

    Science.gov (United States)

    Lawrence, Gregory B.; Fernandez, Ivan J.; Richter, Daniel D.; Ross, Donald S.; Hazlett, Paul W.; Bailey, Scott W.; Oiumet, Rock; Warby, Richard A.F.; Johnson, Arthur H.; Lin, Henry; Kaste, James M.; Lapenis, Andrew G.; Sullivan, Timothy J.

    2013-01-01

    Environmental change is monitored in North America through repeated measurements of weather, stream and river flow, air and water quality, and most recently, soil properties. Some skepticism remains, however, about whether repeated soil sampling can effectively distinguish between temporal and spatial variability, and efforts to document soil change in forest ecosystems through repeated measurements are largely nascent and uncoordinated. In eastern North America, repeated soil sampling has begun to provide valuable information on environmental problems such as air pollution. This review synthesizes the current state of the science to further the development and use of soil resampling as an integral method for recording and understanding environmental change in forested settings. The origins of soil resampling reach back to the 19th century in England and Russia. The concepts and methodologies involved in forest soil resampling are reviewed and evaluated through a discussion of how temporal and spatial variability can be addressed with a variety of sampling approaches. Key resampling studies demonstrate the type of results that can be obtained through differing approaches. Ongoing, large-scale issues such as recovery from acidification, long-term N deposition, C sequestration, effects of climate change, impacts from invasive species, and the increasing intensification of soil management all warrant the use of soil resampling as an essential tool for environmental monitoring and assessment. Furthermore, with better awareness of the value of soil resampling, studies can be designed with a long-term perspective so that information can be efficiently obtained well into the future to address problems that have not yet surfaced.

  1. FNR demonstration experiments Part II: Subcadmium neutron flux measurements

    International Nuclear Information System (INIS)

    Wehe, D.K.; King, J.S.

    1983-01-01

    The FNR HEU-LEU Demonstration Experiments include a comprehensive set of experiments to identify and quantify significant operational differences between two nuclear fuel enrichments. One aspect of these measurements, the subcadmium flux profiling, is the subject of this paper. The flux profiling effort has been accomplished through foil and wire activations, and by rhodium self-powered neutron detector (SPND) mappings. Within the experimental limitations discussed, the program to measure subcadmium flux profiles, lead to the following conclusions: (1) Replacement of a single fresh HEU element by a fresh LEU element at the center of an equilibrium HEU core produces a local flux depression. The ratio of HEU to LEU local flux is 1.19 ± .036, which is, well within experimental uncertainty, equal to the inverse of the U-235 masses for the two elements. (2) Whole core replacement of a large 38 element equilibrium HEU core by a fresh or nearly unburned LEU core reduces the core flux and raises the flux in both D 2 O and H 2 O reflectors. The reduction in the central core region is 40% to 10.0% for the small fresh 29 element LEU core, and 16% to 18% for a 31 element LEU core 482) with low average burnup 2 O reflector fluxes relative to core fluxes as measured by SPND with a fixed value of sensitivity, are in gross disagreement with the same flux ratios measured by Fe and Rh wire activations. Space dependent refinements of S are calculated to give some improvement in the discrepancy but the major part of the correction remains to be resolved

  2. Gaussian process based intelligent sampling for measuring nano-structure surfaces

    Science.gov (United States)

    Sun, L. J.; Ren, M. J.; Yin, Y. H.

    2016-09-01

    Nanotechnology is the science and engineering that manipulate matters at nano scale, which can be used to create many new materials and devices with a vast range of applications. As the nanotech product increasingly enters the commercial marketplace, nanometrology becomes a stringent and enabling technology for the manipulation and the quality control of the nanotechnology. However, many measuring instruments, for instance scanning probe microscopy, are limited to relatively small area of hundreds of micrometers with very low efficiency. Therefore some intelligent sampling strategies should be required to improve the scanning efficiency for measuring large area. This paper presents a Gaussian process based intelligent sampling method to address this problem. The method makes use of Gaussian process based Bayesian regression as a mathematical foundation to represent the surface geometry, and the posterior estimation of Gaussian process is computed by combining the prior probability distribution with the maximum likelihood function. Then each sampling point is adaptively selected by determining the position which is the most likely outside of the required tolerance zone among the candidates and then inserted to update the model iteratively. Both simulationson the nominal surface and manufactured surface have been conducted on nano-structure surfaces to verify the validity of the proposed method. The results imply that the proposed method significantly improves the measurement efficiency in measuring large area structured surfaces.

  3. Apparatus for measuring the nuclear radiation of a sequence of radioactive samples

    International Nuclear Information System (INIS)

    Lohr, W.; Berthold, F.; Allington, R.W.

    1977-01-01

    To measure the nuclear radiation of a sequence of radioactive samples, magazines that hold sample containers are removably positioned in shuttles, some of which are driven step-by-step by a toothed belt that engates racks on the sides of the shuttles from one compartment to another through a measuring station, with the shuttles that are being driven by the belt driving other shuttles not in engagement with the belt at that time. In the measuring station, the sample containers are released from the magazines one at a time through openings in their bottoms and lowered by a reciprocable support to a position adjacent to a radiation detector for the measurement, after which they are raised by the support to the magazine and the shuttle is driven one more step to the next position. 8 figures

  4. Measuring nanocurie quantities of tritium bred in metallic lithium and lithium oxide samples

    International Nuclear Information System (INIS)

    Bertone, P.C.

    1985-01-01

    The LBM program requires that nanocurie quantities of tritium, bred in both lithium oxide pellets and lithium samples, be measured with an uncertainty not exceeding + or - 6%. Two methods of accurately measuring nanocurie quantities of tritium bred in LBM lithium oxide pellets and one method of accurately measuring nanocurie quantities of tritium bred in lithium samples are described. Potential errors associated with these tritium measurement techniques are also discussed

  5. W-Band Transmission MeasurementS and X-Band Dielectric Properties Measurements for a Radome Material Sample

    Science.gov (United States)

    Cravey, Robin L.; Tiemsin, Pacita I.

    1997-01-01

    This paper describes measurements which were performed on a sample of radome material in the Electromagnetic Properties Measurements Laboratory (EPML). The purpose of the measurements described in this paper was to determine the one-way transmission loss through the flat panel of radome material for a frequency range of 84 to 94 GHz, for varying incidence angles. The panel, which was manufactured by Norton Performance Plastics Corporation, was provided to the EPML by TRW. The size of the panel is 40 in x 36 in x 0.422 in and consists of a foam material with one side coated with a smooth white coating (this side will be referred to as the front side). The dielectric properties of the foam material from the inside of the panel were also determined at X-band (8.2-12.4 GHz). The W-band free space measurements are presented first, followed by the X-band dielectric properties measurements.

  6. Error Analysis of Ceramographic Sample Preparation for Coating Thickness Measurement of Coated Fuel Particles

    International Nuclear Information System (INIS)

    Liu Xiaoxue; Li Ziqiang; Zhao Hongsheng; Zhang Kaihong; Tang Chunhe

    2014-01-01

    The thicknesses of four coatings of HTR coated fuel particle are very important parameters. It is indispensable to control the thickness of four coatings of coated fuel particles for the safety of HTR. A measurement method, ceramographic sample-microanalysis method, to analyze the thickness of coatings was developed. During the process of ceramographic sample-microanalysis, there are two main errors, including ceramographic sample preparation error and thickness measurement error. With the development of microscopic techniques, thickness measurement error can be easily controlled to meet the design requirements. While, due to the coated particles are spherical particles of different diameters ranged from 850 to 1000μm, the sample preparation process will introduce an error. And this error is different from one sample to another. It’s also different from one particle to another in the same sample. In this article, the error of the ceramographic sample preparation was calculated and analyzed. Results show that the error introduced by sample preparation is minor. The minor error of sample preparation guarantees the high accuracy of the mentioned method, which indicates this method is a proper method to measure the thickness of four coatings of coated particles. (author)

  7. Quality demonstration of analytica procedure for quantification of 134Cesium and 137Cesium in water samples

    International Nuclear Information System (INIS)

    Santos, T.O.; Farias, E.E.G.; Filho, C.A.S.; França, E.J. de

    2017-01-01

    Intercomparison programs are extremely important in attesting the metrological quality of laboratories, contributing to the improvement of the quality of the analytical procedures adopted and the validation of new analytical methodologies. The objective of this work is to demonstrate the quality of the analyzes of radionuclides Cs-134 and Cs-137 by High Resolution Gamma Spectrometry in water samples of the PNI (National Intercomparison Program). Prior to the start of the analyzes, the vials containing the concentrated samples are shaken for about 10 minutes to ensure homogeneity. A 500 ml aliquot of the concentrated solution is transferred to a beaker for dilution with 1% (v / v) HNO 3 to 4 liters. After being shaken for 30 minutes, 2 liters of this diluted solution are transferred to a Marinelli vessel and then analyzed by High Resolution Gamma Spectrometry (EGAR) using germanium Hyperpure-HPGe detectors. The results obtained are reported to the IRD for analytical performance evaluation. Based on the intercomparison rounds as of year 2011, the SEAMB/CRCN/NE (Environmental Monitoring Service of the Regional Center of Nuclear Sciences of the Northeast) participated in eight rounds of the PNI. All results were within the range of standard deviation evaluation parameter calculated by the IRD. The results obtained demonstrate the analytical capacity of the CRCN-NE for radiometric analyzes in water

  8. Analysis of biological samples by x-ray attenuation measurements

    International Nuclear Information System (INIS)

    Cesareo, R.

    1988-01-01

    Over the last few years there has been an increasing interest in X-ray attenuation measurements, mainly due to the enormous development of computer assisted tomography (CAT). With CAT, analytical information concerning the density and the mean atomic number distributions in a sample is deduced from a large number of attenuation measurements. Particular transmission methods developed, based on the differential attenuation method are discussed. The theoretical background for attenuation of radiation and for differential attenuation of radiation is given. Details about the generation of monoenergetic X-rays are discussed. Applications of attenuation measurements in the field of Medicine are presented

  9. Magnetorheological measurements with consideration for the internal magnetic field in samples

    Energy Technology Data Exchange (ETDEWEB)

    Kordonski, W; Gorodkin, S [QED Technologies International, 1040 University Ave., Rochester, NY 14607 (United States)], E-mail: kordonski@qedmrf.com

    2009-02-01

    The magnetically induced yield stress in a sample of suspension of magnetic particles is associated with formation of a field-oriented structure, the strength of which depends on the degree of particles magnetization. This factor is largely defined by the actual magnetic field strength in the sample. At the same time it is common practice to present and analyze magnetorheological characteristics as a function of the applied magnetic field. Uncertainty of an influence function in magnetorheology hampers interpretation of data obtained with different measurement configurations. It was shown in this paper that rheological response of magnetorheological fluid to the applied magnetic field is defined by the sample's actual (internal) magnetic field intensity, which, in turn, depends on sample geometry and field orientation all other factors being equal. Utilization of the sample's actual field as an influence function in magnetorheology allows proper interpretation of data obtained with different measuring system configurations. Optimization of the actual internal field is a promising approach in designing of energy efficient magnetorheological devices.

  10. Measurement of technetium-99 in soil samples collected in Marshall Islands

    Energy Technology Data Exchange (ETDEWEB)

    Tagami, K.; Uchida, S. [National Inst. of Radiological Sciences, Environmental and Toxicological Sciences Research Group, Chiba (Japan)

    2000-07-01

    Extraction techniques for recovery of technetium-99 ({sup 99}Tc) for ICP-MS measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for {sup 99}Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the {sup 99}Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The {sup 99}Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq/g-dw. The limit of detection for {sup 99}Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq/g-dw under standard operating conditions. (author)

  11. Measurement of technetium-99 in soil samples collected in Marshall Islands

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.

    2000-01-01

    Extraction techniques for recovery of technetium-99 ( 99 Tc) for ICP-MS measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99 Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99 Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99 Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq/g-dw. The limit of detection for 99 Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq/g-dw under standard operating conditions. (author)

  12. Resonance ionization mass spectrometry system for measurement of environmental samples

    International Nuclear Information System (INIS)

    Pibida, L.; McMahon, C.A.; Noertershaeuser, W.; Bushaw, B.A.

    2002-01-01

    A resonance ionization mass spectrometry (RIMS) system has been developed at the National Institute of Standards and Technology (NIST) for sensitive and selective determination of radio-cesium in the environment. The overall efficiency was determined to be 4x10-7 with a combined (laser and mass spectrometer) selectivity of 108 for both 135Cs and 137Cs with respect to 133Cs. RIMS isotopic ratio measurements of 135Cs/ 137Cs were performed on a nuclear fuel burn-up sample and compared to measurements on a similar system at Pacific Northwest National Laboratory (PNNL) and to conventional thermal ionization mass spectrometry (TIMS). Results of preliminary RIMS investigations on a freshwater lake sediment sample are also discussed

  13. Quality control of measurements made on fixed-area sample plots

    Science.gov (United States)

    Ola Lindgren

    2000-01-01

    The paper describes results from a large program for quality control of forest measurements. The performance of 87 surveyors was evaluated. Tree heights were usually measured well, whereas the counting of tree-rings on increment cores was a source of considerable bias for many surveyors. During tree count on sample plots, many surveyors had a tendency to forget trees,...

  14. Spatio-Temporal Image Correlation Spectroscopy Measurements of Flow Demonstrated in Microfluidic Channels

    Science.gov (United States)

    Rossow, Molly; Mantulin, William W.; Gratton, Enrico

    2009-01-01

    Accurate blood flow measurements during surgery can improve the operations chance of success. We developed Near-infrared Spatio-Temporal Image Spectroscopy (NIR-STICS), which has the potential to make blood flow measurements that are difficult to accomplish with existing methods. Specifically, we propose the technique and we show feasibility on phantom measurements. NIR-STICS has the potential of measuring the fluid velocity in small blood vessels (less than 1mm in diameter) and of creating a map of blood flow rates over an area of approximately 1cm2. NIR-STICS employs near-infrared spectroscopy to probe inside blood vessel walls and spatio-temporal image correlation spectroscopy to directly—without the use of a model—extract fluid velocity from the fluctuations within an image. Here we present computer simulations and experiments on a phantom system that demonstrate the effectiveness of NIR-STICS. PMID:19405744

  15. Generalized sample entropy analysis for traffic signals based on similarity measure

    Science.gov (United States)

    Shang, Du; Xu, Mengjia; Shang, Pengjian

    2017-05-01

    Sample entropy is a prevailing method used to quantify the complexity of a time series. In this paper a modified method of generalized sample entropy and surrogate data analysis is proposed as a new measure to assess the complexity of a complex dynamical system such as traffic signals. The method based on similarity distance presents a different way of signals patterns match showing distinct behaviors of complexity. Simulations are conducted over synthetic data and traffic signals for providing the comparative study, which is provided to show the power of the new method. Compared with previous sample entropy and surrogate data analysis, the new method has two main advantages. The first one is that it overcomes the limitation about the relationship between the dimension parameter and the length of series. The second one is that the modified sample entropy functions can be used to quantitatively distinguish time series from different complex systems by the similar measure.

  16. 36Cl AMS measurement of JCO samples

    International Nuclear Information System (INIS)

    Arai, D.; Seki, R.; Nagashima, Y.; Takahashi, T.; Kume, H.; Mawatari, R.

    2000-01-01

    A critical nuclear accident occurred at the nuclear fuel processing facility, JCO, in Tokaimura, Ibaraki prefecture, Japan on 30 September 1999, and a lot of neutron particle were released in the environment. In order to estimate the total neutron flux, we measured the yield of 36 Cl radioisotopes in the samples being collected from the accident site. The neutron flux can be estimated from the ratio of 36 Cl to 35 Cl because the 36 Cl nuclei are created from 35 Cl through a thermal neutron capture process, 35 Cl(n,γ) 36 Cl. (author)

  17. On the optimal sampling of bandpass measurement signals through data acquisition systems

    International Nuclear Information System (INIS)

    Angrisani, L; Vadursi, M

    2008-01-01

    Data acquisition systems (DAS) play a fundamental role in a lot of modern measurement solutions. One of the parameters characterizing a DAS is its maximum sample rate, which imposes constraints on the signals that can be alias-free digitized. Bandpass sampling theory singles out separated ranges of admissible sample rates, which can be significantly lower than carrier frequency. But, how to choose the most convenient sample rate according to the purpose at hand? The paper proposes a method for the automatic selection of the optimal sample rate in measurement applications involving bandpass signals; the effects of sample clock instability and limited resolution are also taken into account. The method allows the user to choose the location of spectral replicas of the sampled signal in terms of normalized frequency, and the minimum guard band between replicas, thus introducing a feature that no DAS currently available on the market seems to offer. A number of experimental tests on bandpass digitally modulated signals are carried out to assess the concurrence of the obtained central frequency with the expected one

  18. Scanning transmission ion microscopy mass measurements for quantitative trace element analysis within biological samples and validation using atomic force microscopy thickness measurements

    Energy Technology Data Exchange (ETDEWEB)

    Deves, Guillaume [Laboratoire de chimie nucleaire analytique et bioenvironnementale, UMR 5084, CNRS-Universite de Bordeaux 1, BP 120 Chemin du solarium, F33175 Gradignan cedex (France)]. E-mail: deves@cenbg.in2p3.fr; Cohen-Bouhacina, Touria [Centre de Physique Moleculaire Optique et Hertzienne, Universite de Bordeaux 1, 351, cours de la Liberation, F33405 Talence cedex (France); Ortega, Richard [Laboratoire de chimie nucleaire analytique et bioenvironnementale, UMR 5084, CNRS-Universite de Bordeaux 1, BP 120 Chemin du solarium, F33175 Gradignan cedex (France)

    2004-10-08

    We used the nuclear microprobe techniques, micro-PIXE (particle-induced X-ray emission), micro-RBS (Rutherford backscattering spectrometry) and scanning transmission ion microscopy (STIM) in order to perform the characterization of trace element content and spatial distribution within biological samples (dehydrated cultured cells, tissues). The normalization of PIXE results was usually expressed in terms of sample dry mass as determined by micro-RBS recorded simultaneously to micro-PIXE. However, the main limit of RBS mass measurement is the sample mass loss occurring during irradiation and which could be up to 30% of the initial sample mass. We present here a new methodology for PIXE normalization and quantitative analysis of trace element within biological samples based on dry mass measurement performed by mean of STIM. The validation of STIM cell mass measurements was obtained in comparison with AFM sample thickness measurements. Results indicated the reliability of STIM mass measurement performed on biological samples and suggested that STIM should be performed for PIXE normalization. Further information deriving from direct confrontation of AFM and STIM analysis could as well be obtained, like in situ measurements of cell specific gravity within cells compartment (nucleolus and cytoplasm)

  19. Experimental Development and Demonstration of Ultrasonic Measurement Diagnostics for Sodium Fast Reactor Thermal-hydraulics

    Energy Technology Data Exchange (ETDEWEB)

    Tokuhiro, Akira; Jones, Byron

    2013-09-13

    This research project will address some of the principal technology issues related to sodium-cooled fast reactors (SFR), primarily the development and demonstration of ultrasonic measurement diagnostics linked to effective thermal convective sensing under normatl and off-normal conditions. Sodium is well-suited as a heat transfer medium for the SFR. However, because it is chemically reactive and optically opaque, it presents engineering accessibility constraints relative to operations and maintenance (O&M) and in-service inspection (ISI) technologies that are currently used for light water reactors. Thus, there are limited sensing options for conducting thermohydraulic measurements under normal conditions and off-normal events (maintenance, unanticipated events). Acoustic methods, primarily ultrasonics, are a key measurement technology with applications in non-destructive testing, component imaging, thermometry, and velocimetry. THis project would have yielded a better quantitative and qualitative understanding of the thermohydraulic condition of solium under varied flow conditions. THe scope of work will evaluate and demonstrate ultrasonic technologies and define instrumentation options for the SFR.

  20. Measuring Radionuclides in the environment: radiological quantities and sampling designs

    International Nuclear Information System (INIS)

    Voigt, G.

    1998-10-01

    One aim of the workshop was to support and provide an ICRU report committee (International Union of Radiation Units) with actual information on techniques, data and knowledge of modern radioecology when radionuclides are to be measured in the environment. It has been increasingly recognised that some studies in radioecology, especially those involving both field sampling and laboratory measurements, have not paid adequate attention to the problem of obtaining representative, unbiased samples. This can greatly affect the quality of scientific interpretation, and the ability to manage the environment. Further, as the discipline of radioecology has developed, it has seen a growth in the numbers of quantities and units used, some of which are ill-defined and which are non-standardised. (orig.)

  1. Demonstration of a Sensitive Method to Measure Nuclear-Spin-Dependent Parity Violation

    Science.gov (United States)

    Altuntaş, Emine; Ammon, Jeffrey; Cahn, Sidney B.; DeMille, David

    2018-04-01

    Nuclear-spin-dependent parity violation (NSD-PV) effects in atoms and molecules arise from Z0 boson exchange between electrons and the nucleus, and from the magnetic interaction between electrons and the parity-violating nuclear anapole moment. We demonstrate measurements of NSD-PV that use an enhancement of the effect in diatomic molecules, here using the test system 138Ba 19. Our sensitivity surpasses that of any previous atomic parity violation measurement. We show that systematic errors can be suppressed to at least the level of the present statistical sensitivity. We measure the matrix element W of the NSD-PV interaction with total uncertainty δ W /(2 π )<0.7 Hz , for each of two configurations where W must have different signs. This sensitivity would be sufficient to measure NSD-PV effects of the size anticipated across a wide range of nuclei including 137Ba in 137BaF, where |W |/(2 π )≈5 Hz is expected.

  2. Characterization of electron microscopes with binary pseudo-random multilayer test samples

    International Nuclear Information System (INIS)

    Yashchuk, Valeriy V.; Conley, Raymond; Anderson, Erik H.; Barber, Samuel K.; Bouet, Nathalie; McKinney, Wayne R.; Takacs, Peter Z.; Voronov, Dmitriy L.

    2010-01-01

    We discuss the results of SEM and TEM measurements with the BPRML test samples fabricated from a BPRML (WSi2/Si with fundamental layer thickness of 3 nm) with a Dual Beam FIB (focused ion beam)/SEM technique. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize x-ray microscopes. Corresponding work with x-ray microscopes is in progress.

  3. Measurement of 239Pu in urine samples at ultra-trace levels using a 1 MV compact AMS system

    International Nuclear Information System (INIS)

    Hernandez-Mendoza, H.; Chamizo, E.; Yllera, A.; Garcia-Leon, M.; Delgado, A.

    2010-01-01

    Routine bioassay monitoring of Pu intake in exposed workers of research and nuclear industry is usually performed by alpha spectrometry. This technique involves large sample volumes of urine and time-consuming preparative and counting protocols. Compact accelerator mass spectrometry (AMS) facilities make feasible the determination of ultra low-level Pu activity concentrations and Pu isotopic ratios in biological samples (blood, urine and feces), being a rapid and cost-effective measurement technique. The plutonium results in urine samples presented here have been obtained on the 1 MV compact AMS system sited at the Centro Nacional de Aceleradores (CNA), in Seville, Spain. In this work, a different methodological approach has been developed alternative to the 'classical' preparation of urine samples for alpha spectrometry. The procedure avoids the Pu precipitation step, and involves acid sample evaporation and acid digestion in a microwave oven. Finally, purification of plutonium was achieved by using chromatography columns filled up with BioRad AG1X2 anion exchange resin (Bio-Rad Laboratories Inc.). The total time needed for analysis is about 10 h, unlike the 'classical' methods based on alpha spectrometry which need about 1 week. At present, it has been demonstrated that this method allows quantifying 239 Pu activity concentrations in urine of, at least, 30 μBq (13 fg 239 Pu). We can conclude that the procedure would be suitable to perform in vitro routine bioassay measurements. Moreover, the innovative application of AMS opens new and interesting analytical alternatives in this field.

  4. Radiocarbon measurements of small gaseous samples at CologneAMS

    Science.gov (United States)

    Stolz, A.; Dewald, A.; Altenkirch, R.; Herb, S.; Heinze, S.; Schiffer, M.; Feuerstein, C.; Müller-Gatermann, C.; Wotte, A.; Rethemeyer, J.; Dunai, T.

    2017-09-01

    A second SO-110 B (Arnold et al., 2010) ion source was installed at the 6 MV CologneAMS for the measurement of gaseous samples. For the gas supply a dedicated device from Ionplus AG was connected to the ion source. Special effort was devoted to determine optimized operation parameters for the ion source, which give a high carbon current output and a high 14C- yield. The latter is essential in cases when only small samples are available. Additionally a modified immersion lens and modified target pieces were tested and the target position was optimized.

  5. Internal Stress Distribution Measurement of TIG Welded SUS304 Samples Using Neutron Diffraction Technique

    Science.gov (United States)

    Muslih, M. Refai; Sumirat, I.; Sairun; Purwanta

    2008-03-01

    The distribution of residual stress of SUS304 samples that were undergone TIG welding process with four different electric currents has been measured. The welding has been done in the middle part of the samples that was previously grooved by milling machine. Before they were welded the samples were annealed at 650 degree Celsius for one hour. The annealing process was done to eliminate residual stress generated by grooving process so that the residual stress within the samples was merely produced from welding process. The calculation of distribution of residual stress was carried out by measuring the strains within crystal planes of Fe(220) SUS304. Strain, Young modulus, and Poisson ratio of Fe(220) SUS304 were measured using DN1-M neutron diffractometer. Young modulus and Poisson ratio of Fe(220) SUS304 sample were measured in-situ. The result of calculations showed that distribution of residual stress of SUS304 in the vicinity of welded area is influenced both by treatments given at the samples-making process and by the electric current used during welding process.

  6. A thermostat for precise measurements of thermoresistance of small samples

    International Nuclear Information System (INIS)

    Rusinowski, Z.; Slowinski, B.; Winiewski, R.

    1996-01-01

    In the work a simple experimental set-up is described in which special attention is paid to the important problem of the thermal stability of thermoresistance measurements of small samples of manganin

  7. Measurement of the tritium concentration in the fractionated distillate from environmental water samples.

    Science.gov (United States)

    Atkinson, Robert; Eddy, Teresa; Kuhne, Wendy; Jannik, Tim; Brandl, Alexander

    2014-09-01

    Standard procedures for the measurement of tritium in water samples often require distillation of an appropriate sample aliquot. This distillation process may result in a fractionation of tritiated water and regular light water due to the vapor pressure isotope effect, introducing either a bias or an additional contribution to the total tritium measurement uncertainty. The current study investigates the relative change in vapor pressure isotope effect in the course of the distillation process, distinguishing it from and extending previously published measurements. The separation factor as a quantitative measure of the vapor pressure isotope effect is found to assume values of 1.04 ± 0.036, 1.05 ± 0.026, and 1.07 ± 0.038, depending on the vigor of the boiling process during distillation of the sample. A lower heat setting in the experimental setup, and therefore a less vigorous boiling process, results in a larger value for the separation factor. For a tritium measurement in water samples where the first 5 mL are discarded, the tritium concentration could be underestimated by 4-7%. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Extended depth measurement for a Stokes sample imaging polarimeter

    Science.gov (United States)

    Dixon, Alexander W.; Taberner, Andrew J.; Nash, Martyn P.; Nielsen, Poul M. F.

    2018-02-01

    A non-destructive imaging technique is required for quantifying the anisotropic and heterogeneous structural arrangement of collagen in soft tissue membranes, such as bovine pericardium, which are used in the construction of bioprosthetic heart valves. Previously, our group developed a Stokes imaging polarimeter that measures the linear birefringence of samples in a transmission arrangement. With this device, linear retardance and optic axis orientation; can be estimated over a sample using simple vector algebra on Stokes vectors in the Poincaré sphere. However, this method is limited to a single path retardation of a half-wave, limiting the thickness of samples that can be imaged. The polarimeter has been extended to allow illumination of narrow bandwidth light of controllable wavelength through achromatic lenses and polarization optics. We can now take advantage of the wavelength dependence of relative retardation to remove ambiguities that arise when samples have a single path retardation of a half-wave to full-wave. This effectively doubles the imaging depth of this method. The method has been validated using films of cellulose of varied thickness, and applied to samples of bovine pericardium.

  9. The feasible research with measuring radon for taking the soils sample

    International Nuclear Information System (INIS)

    Zeng Bing, Ge Liangquan; Liu Hefan; Li Yeqiang; Zhang Jinzhao; Song Xiao'an

    2010-01-01

    It explains the mechanism of the separation of soil's radon. Through the designed experiment, it confirms the feasibility of measuring radon for taking the soil's sample. It determines the content of the radon and its sub field with indoor and outside through ways of the activated charcoal adsorption, the initiative suction and the diameter mark etching, also the 226 Ra. The paper indicates: it is feasible with measuring radon for taking the soil's sample, and the stability of data is that indoor data are better than outside's. The temperature, the humidity, the rainfall amount, the intensity and so on are the serious influence of the data. If you want to take a soil's sample, you must avoid the rain as far as possible, and avoid the fault zone, the belt of folded strata and complex geologic structure region, and so on. (authors)

  10. Experimental verification of air flow rate measurement for representative isokinetic air sampling in ventilation stacks

    International Nuclear Information System (INIS)

    Okruhlica, P.; Mrtvy, M.; Kopecky, Z.

    2009-01-01

    Nuclear facilities are obliged to monitor their discharge's influence on environment. Main monitored factions in NPP's ventilation stacks are usually noble gasses, particulates and iodine. These factions are monitored in air sampled from ventilation stack by means of sampling rosette and bypass followed with on-line measuring monitors and balance sampling devices with laboratory evaluations. Correct air flow rate measurement and representative iso-kinetic air sampling system is essential for physical correct and metrological accurate evaluation of discharge influence on environment. Pairs of measuring sensors (Anemometer, pressure gauge, thermometer and humidity meter) are symmetrically placed in horizontal projection of stack on positions based on measured air flow velocity distribution characteristic, Analogically diameter of sampling rosette nozzles and their placement in the middle of 6 - 7 annuluses are calculated for assurance of representative iso-kinetic sampling. (authors)

  11. Experimental verification of air flow rate measurement for representative isokinetic air sampling in ventilation stacks

    International Nuclear Information System (INIS)

    Okruhlica, P.; Mrtvy, M.; Kopecky, Z.

    2008-01-01

    Nuclear facilities are obliged to monitor their discharge's influence on environment. Main monitored factions in NPP's ventilation stacks are usually noble gasses, particulates and iodine. These factions are monitored in air sampled from ventilation stack by means of sampling rosette and bypass followed with on-line measuring monitors and balance sampling devices with laboratory evaluations. Correct air flow rate measurement and representative iso-kinetic air sampling system is essential for physical correct and metrological accurate evaluation of discharge influence on environment. Pairs of measuring sensors (Anemometer, pressure gauge, thermometer and humidity meter) are symmetrically placed in horizontal projection of stack on positions based on measured air flow velocity distribution characteristic, Analogically diameter of sampling rosette nozzles and their placement in the middle of 6- 7 annuluses are calculated for assurance of representative iso-kinetic sampling. (authors)

  12. Diagnostic accuracy of language sample measures with Persian-speaking preschool children.

    Science.gov (United States)

    Kazemi, Yalda; Klee, Thomas; Stringer, Helen

    2015-04-01

    This study examined the diagnostic accuracy of selected language sample measures (LSMs) with Persian-speaking children. A pre-accuracy study followed by phase I and II studies are reported. Twenty-four Persian-speaking children, aged 42 to 54 months, with primary language impairment (PLI) were compared to 27 age-matched children without PLI on a set of measures derived from play-based, conversational language samples. Results showed that correlations between age and LSMs were not statistically significant in either group of children. However, a majority of LSMs differentiated children with and without PLI at the group level (phase I), while three of the measures exhibited good diagnostic accuracy at the level of the individual (phase II). We conclude that general LSMs are promising for distinguishing between children with and without PLI. Persian-specific measures are mainly helpful in identifying children without language impairment while their ability to identify children with PLI is poor.

  13. Automation of the radiation measuring facilities for samples in health physics - MA 9

    International Nuclear Information System (INIS)

    Martini, M.

    1980-12-01

    Routine radation measurements of samples are performed by the HMI health physics department by means of test stations for individual samples and multiple samples (using a changing equipment). The basic device of these test stations is a SCALER/TIMER system (BF 22/25, BERTHOLD Corp.). This measuring facility has been extended by a CAMAC intrumentation which incorporates an autonomous CAMAC processor (CAPRO-1, INCAA B.V.) for monitoring an automatic control of the system. The programming language is BASIC. A DECwriter (LA 34) is used for user interaction and for printing the measurement results. This report describes the features of this system and present some examples of, the dialogue with the system and the printout of data. (orig.) [de

  14. FDTD simulations and analysis of thin sample dielectric properties measurements using coaxial probes

    Energy Technology Data Exchange (ETDEWEB)

    Bringhurst, S.; Iskander, M.F.; White, M.J. [Univ. of Utah, Salt Lake City, UT (United States). Electrical Engineering Dept.

    1996-12-31

    A metallized ceramic probe has been designed for high temperature broadband dielectric properties measurements. The probe was fabricated out of an alumina tube and rod as the outer and inner conductors respectively. The alumina was metallized with a 3 mil layer of moly-manganese and then covered with a 0.5 mil protective layer of nickel plating. The probe has been used to make complex dielectric properties measurements over the complete frequency band from 500 MHz to 3 GHz, and for temperatures as high as 1,000 C. A 3D Finite-Difference Time-Domain (FDTD) code was used to help investigate the feasibility of this probe to measure the complex permittivity of thin samples. It is shown that by backing the material under test with a standard material of known dielectric constant, the complex permittivity of thin samples can be measured accurately using the developed FDTD algorithm. This FDTD procedure for making thin sample dielectric properties measurements will be described.

  15. Rewards of bridging the divide between measurement and clinical theory: demonstration of a bifactor model for the Brief Symptom Inventory.

    Science.gov (United States)

    Thomas, Michael L

    2012-03-01

    There is growing evidence that psychiatric disorders maintain hierarchical associations where general and domain-specific factors play prominent roles (see D. Watson, 2005). Standard, unidimensional measurement models can fail to capture the meaningful nuances of such complex latent variable structures. The present study examined the ability of the multidimensional item response theory bifactor model (see R. D. Gibbons & D. R. Hedeker, 1992) to improve construct validity by serving as a bridge between measurement and clinical theories. Archival data consisting of 688 outpatients' psychiatric diagnoses and item-level responses to the Brief Symptom Inventory (BSI; L. R. Derogatis, 1993) were extracted from files at a university mental health clinic. The bifactor model demonstrated superior fit for the internal structure of the BSI and improved overall diagnostic accuracy in the sample (73%) compared with unidimensional (61%) and oblique simple structure (65%) models. Consistent with clinical theory, multiple sources of item variance were drawn from individual test items. Test developers and clinical researchers are encouraged to consider model-based measurement in the assessment of psychiatric distress.

  16. Using the New Postacute Care Quality Measures to Demonstrate the Value of Occupational Therapy.

    Science.gov (United States)

    Sandhu, Sharmila; Furniss, Jeremy; Metzler, Christina

    As the health care system continues to evolve toward one based on quality not quantity, demonstrating the value of occupational therapy has never been more important. Providing high-quality services, achieving optimal outcomes, and identifying and promoting occupational therapy's distinct value are the responsibilities of all practitioners. In relation to the Improving Medicare Post-Acute Care Transformation (IMPACT) Act of 2014, the Centers for Medicare and Medicaid Services (CMS) is implementing new functional items and related outcome performance measures across postacute care (PAC) settings. Practitioners can demonstrate the role and value of occupational therapy services through their participation in data collection and the interpretation of the resulting performance measures. In this column, we review the objectives of the IMPACT Act, introduce the new self-care and mobility items and outcome performance measures being implemented in PAC settings, and describe ways to use these new data to advocate for occupational therapy. We also discuss American Occupational Therapy Association initiatives to provide materials and guidance for occupational therapy practitioners to contribute to PAC data collection. Copyright © 2018 by the American Occupational Therapy Association, Inc.

  17. Experimental technique to measure thoron generation rate of building material samples using RAD7 detector

    International Nuclear Information System (INIS)

    Csige, I.; Szabó, Zs.; Szabó, Cs.

    2013-01-01

    Thoron ( 220 Rn) is the second most abundant radon isotope in our living environment. In some dwellings it is present in significant amount which calls for its identification and remediation. Indoor thoron originates mainly from building materials. In this work we have developed and tested an experimental technique to measure thoron generation rate in building material samples using RAD7 radon-thoron detector. The mathematical model of the measurement technique provides the thoron concentration response of RAD7 as a function of the sample thickness. For experimental validation of the technique an adobe building material sample was selected for measuring the thoron concentration at nineteen different sample thicknesses. Fitting the parameters of the model to the measurement results, both the generation rate and the diffusion length of thoron was estimated. We have also determined the optimal sample thickness for estimating the thoron generation rate from a single measurement. -- Highlights: • RAD7 is used for the determination of thoron generation rate (emanation). • The described model takes into account the thoron decay and attenuation. • The model describes well the experimental results. • A single point measurement method is offered at a determined sample thickness

  18. Experimental demonstration of the finite measurement time effect on the Feynman-{alpha} technique

    Energy Technology Data Exchange (ETDEWEB)

    Wallerbos, E.J.M.; Hoogenboom, J.E

    1998-09-01

    The reactivity of a subcritical system is determined by fitting two different theoretical models to a measured Feynman-{alpha} curve. The first model is the expression usually found in the literature, which can be shown to be the expectation value of the experimental quality if the measurement time is infinite. The second model is a new expression which is the expectation value of the experimental quantity for a finite measurement time. The reactivity inferred with the new model is seen to be independent of the length of the fitting interval, whereas the reactivity inferred with the conventional model is seen to vary. This difference demonstrates the effect of the finite measurement time. As a reference, the reactivity is also measured with the pulsed-neutron source method. It is seen to be in good agreement with the reactivity obtained with the Feynman-{alpha} technique when the new expression is applied.

  19. Performance demonstration program plan for RCRA constituent analysis of solidified wastes

    International Nuclear Information System (INIS)

    1995-06-01

    Performance Demonstration Programs (PDPS) are designed to help ensure compliance with the Quality Assurance Objectives (QAOs) for the Waste Isolation Pilot Plant (WIPP). The PDPs are intended for use by the Department of Energy (DOE) Carlsbad Area Office (CAO) to assess and approve the laboratories and other measurement facilities supplying services for the characterization of WIPP TRU waste. The PDPs may also be used by CAO in qualifying laboratories proposing to supply additional analytical services that are required for other than waste characterization, such as WIPP site operations. The purpose of this PDP is to test laboratory performance for the analysis of solidified waste samples for TRU waste characterization. This performance will be demonstrated by the successful analysis of blind audit samples of simulated, solidified TRU waste according to the criteria established in this plan. Blind audit samples (hereinafter referred to as PDP samples) will be used as an independent means to assess laboratory performance regarding compliance with the QAOs. The concentration of analytes in the PDP samples will address levels of regulatory concern and will encompass the range of concentrations anticipated in actual waste characterization samples. Analyses that are required by the WIPP to demonstrate compliance with various regulatory requirements and which are included in the PDP must be performed by laboratories that demonstrate acceptable performance in the PDP. These analyses are referred to as WIPP analyses and the samples on which they are performed are referred to as WIPP samples for the balance of this document

  20. Hall effect measurements on proton-irradiated ROSE samples

    International Nuclear Information System (INIS)

    Biggeri, U.; Bruzzi, M.; Borchi, E.

    1997-01-01

    Bulk samples obtained from two wafers of a silicon monocrystal material produced by Float-Zone refinement have been analyzed using the four-point probe method. One of the wafers comes from an oxygenated ingot; two sets of pure and oxygenated samples have been irradiated with 24 GeV/c protons in the fluence range from 10 13 p/cm 2 to 2x10 14 p/cm 2 . Van der Pauw resistivity and Hall coefficient have been measured before and after irradiation as a function of the temperature. A thermal treatment (30 minutes at 100C) has been performed to accelerate the reverse annealing effect in the irradiated silicon. The irradiated samples show the same exponential dependence of the resistivity and of the Hall coefficient on the temperature from 370K to 100K, corresponding to the presence of radiation-induced deep energy levels around 0.6-0.7eV in the silicon gap. The free carrier concentrations (n, p) have been evaluated in the investigated fluence range. The inversion of the conductivity type from n to p occurred respectively at 7x10 13 p/cm 2 and at 4x10 13 p/cm 2 before and after the annealing treatment, for both the two sets. Only slight differences have been detected between the pure and oxygenated samples

  1. The state of the art of the impact of sampling uncertainty on measurement uncertainty

    Science.gov (United States)

    Leite, V. J.; Oliveira, E. C.

    2018-03-01

    The measurement uncertainty is a parameter that marks the reliability and can be divided into two large groups: sampling and analytical variations. Analytical uncertainty is a controlled process, performed in the laboratory. The same does not occur with the sampling uncertainty, which, because it faces several obstacles and there is no clarity on how to perform the procedures, has been neglected, although it is admittedly indispensable to the measurement process. This paper aims at describing the state of the art of sampling uncertainty and at assessing its relevance to measurement uncertainty.

  2. Using Language Sample Analysis in Clinical Practice: Measures of Grammatical Accuracy for Identifying Language Impairment in Preschool and School-Aged Children.

    Science.gov (United States)

    Eisenberg, Sarita; Guo, Ling-Yu

    2016-05-01

    This article reviews the existing literature on the diagnostic accuracy of two grammatical accuracy measures for differentiating children with and without language impairment (LI) at preschool and early school age based on language samples. The first measure, the finite verb morphology composite (FVMC), is a narrow grammatical measure that computes children's overall accuracy of four verb tense morphemes. The second measure, percent grammatical utterances (PGU), is a broader grammatical measure that computes children's accuracy in producing grammatical utterances. The extant studies show that FVMC demonstrates acceptable (i.e., 80 to 89% accurate) to good (i.e., 90% accurate or higher) diagnostic accuracy for children between 4;0 (years;months) and 6;11 in conversational or narrative samples. In contrast, PGU yields acceptable to good diagnostic accuracy for children between 3;0 and 8;11 regardless of sample types. Given the diagnostic accuracy shown in the literature, we suggest that FVMC and PGU can be used as one piece of evidence for identifying children with LI in assessment when appropriate. However, FVMC or PGU should not be used as therapy goals directly. Instead, when children are low in FVMC or PGU, we suggest that follow-up analyses should be conducted to determine the verb tense morphemes or grammatical structures that children have difficulty with. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  3. Sophistication of 14C measurement at JAEA-AMS-MUTSU. Attempt on a small quantity of sample

    International Nuclear Information System (INIS)

    Tanaka, Takayuki; Kabuto, Shoji; Kinoshita, Naoki; Yamamoto, Nobuo

    2010-01-01

    In the investigations on substance dynamics using the molecular weight and chemical fractionation, the utilization of 14 C measurement by an accelerator mass spectrometry (AMS) have started. As a result of the fractionation, sample contents required for AMS measurement have been downsized. We expect that this trend toward a small quantity of sample will be steadily accelerated in the future. As 14 C measurement by AMS established at Mutsu office require about 2 mg of sample content at present, our AMS lags behind the others in the trend. We try to downsize the needed sample content for 14 C measurement by our AMS. In this study, we modified the shape of the target-piece in which the sample is packed and which is regularly needed to radiocarbon measurement by our AMS. Moreover, we improved on the apparatus needed to pack the sample. As a result of the improvement, we revealed that it is possible to measure the 14 C using our AMS even by the amount of the sample of about 0.5 mg. (author)

  4. Practice and experience in traceability of radioactivity measurements of environmental samples

    International Nuclear Information System (INIS)

    Huang Zhijian

    1990-01-01

    This paper discusses some aspects on radioactivity measurement traceability and summarizes the work on quality assurance of radioactivity measurements of environmental samples in the laboratory, including transfer of standards, preparation of reference materials, and calibration of efficiency for volumse surces with Ge(Li) spectrometer. Some practical activitis regarding intercomparison of radioactivity measurements and other traceabillity-related activities are also described. Some sugestions relating to performing quality assurance are made

  5. Technical developments for accurate determination of amount of samples used for TOF measurements

    Directory of Open Access Journals (Sweden)

    Terada Kazushi

    2017-01-01

    Full Text Available Activity determination of 241,243Am samples has been performed with two separate methods of calorimetry and gamma-ray spectroscopy. Decay heat measurements of the samples were carried out by using a calorimeter, and activities of the samples were accurately determined with uncertainties less than 0.45%. The primary source of uncertainty in the calorimetric method is the accuracy of available half-life data. Gamma-ray detection efficiencies of a HPGe detector were determined with uncertainties of 1.5% by combining measured efficiencies and Monte Carlo simulation. Activities of the samples were determined with uncertainties less than 2.0% by gamma-ray spectroscopy and were concordant with those of the calorimetry.

  6. Environmental Measurement-While-Drilling System and Horizontal Directional Drilling Technology Demonstration, Hanford Site

    International Nuclear Information System (INIS)

    Williams, C.V.; Lockwood, G.J.; Normann, R.A.; Myers, D.A.; Gardner, M.G.; Williamson, T.; Huffman, J.

    1999-01-01

    The Environmental Measurement-While-Drilling (EMWD) system and Horizontal Directional Drilling (HDD) were successfully demonstrated at the Mock Tank Leak Simulation Site and the Drilling Technology Test Site, Hanford, Washington. The use of directional drilling offers an alternative to vertical drilling site characterization. Directional drilling can develop a borehole under a structure, such as a waste tank, from an angled entry and leveling off to horizontal at the desired depth. The EMWD system represents an innovative blend of new and existing technology that provides the capability of producing real-time environmental and drill bit data during drilling operations. The technology demonstration consisted of the development of one borehole under a mock waste tank at a depth of approximately minus8 m (minus27 ft.), following a predetermined drill path, tracking the drill path to within a radius of approximately1.5 m (5 ft.), and monitoring for zones of radiological activity using the EMWD system. The purpose of the second borehole was to demonstrate the capability of drilling to a depth of ∼ -21 m (-70 ft.), the depth needed to obtain access under the Hanford waste tanks, and continue drilling horizontally. This report presents information on the HDD and EMWD technologies, demonstration design, results of the demonstrations, and lessons learned

  7. Note: Development of a microfabricated sensor to measure thermal conductivity of picoliter scale liquid samples.

    Science.gov (United States)

    Park, Byoung Kyoo; Yi, Namwoo; Park, Jaesung; Kim, Dongsik

    2012-10-01

    This paper presents a thermal analysis device, which can measure thermal conductivity of picoliter scale liquid sample. We employ the three omega method with a microfabricated AC thermal sensor with nanometer width heater. The liquid sample is confined by a micro-well structure fabricated on the sensor surface. The performance of the instrument was verified by measuring the thermal conductivity of 27-picoliter samples of de-ionized (DI) water, ethanol, methanol, and DI water-ethanol mixtures with accuracies better than 3%. Furthermore, another analytical scheme allows real-time thermal conductivity measurement with 5% accuracy. To the best of our knowledge, this technique requires the smallest volume of sample to measure thermal property ever.

  8. Method for Measuring Thermal Conductivity of Small Samples Having Very Low Thermal Conductivity

    Science.gov (United States)

    Miller, Robert A.; Kuczmarski, Maria a.

    2009-01-01

    This paper describes the development of a hot plate method capable of using air as a standard reference material for the steady-state measurement of the thermal conductivity of very small test samples having thermal conductivity on the order of air. As with other approaches, care is taken to ensure that the heat flow through the test sample is essentially one-dimensional. However, unlike other approaches, no attempt is made to use heated guards to block the flow of heat from the hot plate to the surroundings. It is argued that since large correction factors must be applied to account for guard imperfections when sample dimensions are small, it may be preferable to simply measure and correct for the heat that flows from the heater disc to directions other than into the sample. Experimental measurements taken in a prototype apparatus, combined with extensive computational modeling of the heat transfer in the apparatus, show that sufficiently accurate measurements can be obtained to allow determination of the thermal conductivity of low thermal conductivity materials. Suggestions are made for further improvements in the method based on results from regression analyses of the generated data.

  9. Measurement of technetium-99 in Marshall Islands soil samples by ICP-MS

    Science.gov (United States)

    Tagami; Uchida; Hamilton; Robison

    2000-07-01

    Extraction techniques for recovery of technetium-99 (99Tc) for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (MI) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq g(-1) dry weight (dw). The limit of detection for 99Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq g(-1) dw under standard operating conditions.

  10. Measurement of technetium-99 in Marshall Islands soil samples by ICP-MS

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.; Hamilton, T.; Robison, W.

    2000-01-01

    Extraction techniques for recovery of technetium-99 ( 99 Tc) for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99 Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99 Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99 Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq g -1 dry weight (dw). The limit of detection for 99 Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq g -1 dw under standard operating conditions

  11. Large Sample Neutron Activation Analysis of Heterogeneous Samples

    International Nuclear Information System (INIS)

    Stamatelatos, I.E.; Vasilopoulou, T.; Tzika, F.

    2018-01-01

    A Large Sample Neutron Activation Analysis (LSNAA) technique was developed for non-destructive analysis of heterogeneous bulk samples. The technique incorporated collimated scanning and combining experimental measurements and Monte Carlo simulations for the identification of inhomogeneities in large volume samples and the correction of their effect on the interpretation of gamma-spectrometry data. Corrections were applied for the effect of neutron self-shielding, gamma-ray attenuation, geometrical factor and heterogeneous activity distribution within the sample. A benchmark experiment was performed to investigate the effect of heterogeneity on the accuracy of LSNAA. Moreover, a ceramic vase was analyzed as a whole demonstrating the feasibility of the technique. The LSNAA results were compared against results obtained by INAA and a satisfactory agreement between the two methods was observed. This study showed that LSNAA is a technique capable to perform accurate non-destructive, multi-elemental compositional analysis of heterogeneous objects. It also revealed the great potential of the technique for the analysis of precious objects and artefacts that need to be preserved intact and cannot be damaged for sampling purposes. (author)

  12. Measurement of radioactivity in the environment - Soil - Part 2: Guidance for the selection of the sampling strategy, sampling and pre-treatment of samples

    International Nuclear Information System (INIS)

    2007-01-01

    This part of ISO 18589 specifies the general requirements, based on ISO 11074 and ISO/IEC 17025, for all steps in the planning (desk study and area reconnaissance) of the sampling and the preparation of samples for testing. It includes the selection of the sampling strategy, the outline of the sampling plan, the presentation of general sampling methods and equipment, as well as the methodology of the pre-treatment of samples adapted to the measurements of the activity of radionuclides in soil. This part of ISO 18589 is addressed to the people responsible for determining the radioactivity present in soil for the purpose of radiation protection. It is applicable to soil from gardens, farmland, urban or industrial sites, as well as soil not affected by human activities. This part of ISO 18589 is applicable to all laboratories regardless of the number of personnel or the range of the testing performed. When a laboratory does not undertake one or more of the activities covered by this part of ISO 18589, such as planning, sampling or testing, the corresponding requirements do not apply. Information is provided on scope, normative references, terms and definitions and symbols, principle, sampling strategy, sampling plan, sampling process, pre-treatment of samples and recorded information. Five annexes inform about selection of the sampling strategy according to the objectives and the radiological characterization of the site and sampling areas, diagram of the evolution of the sample characteristics from the sampling site to the laboratory, example of sampling plan for a site divided in three sampling areas, example of a sampling record for a single/composite sample and example for a sample record for a soil profile with soil description. A bibliography is provided

  13. A simplified method for low-level tritium measurement in the environmental water samples

    International Nuclear Information System (INIS)

    Sakuma, Yoichi; Yamanishi, Hirokuni; Ogata, Yoshimune

    2004-01-01

    Low level liquid scintillation counting took much time with a lot of doing to distill off the impurities in the sample water before mixing the sample with the liquid scintillation cocktail. In the light of it, we investigated the possibility of an alternative filtration method for sample purification. The tritium concentration in the environmental water has become very low, and the samples have to be treated by electrolysis enrichment with a liquid scintillation analyzer. Using the solid polymer electrolyte enriching device, there is no need to add neither any electrolyte nor the neutralization after the concentration. If we could replace the distillation process with the filtration, the procedure would be simplified very much. We investigated the procedure and we were able to prove that the reverse osmosis (RO) filtration was available. Moreover, in order to rationalize all through the measurement method, we examined the followings: (1) Improvement of the enriching apparatus. (2) Easier measurement of heavy water concentration using a density meter, instead of a mass spectrometer. The concentration of water samples was measured to determine the enrichment rate of tritium during the electrolysis enrichment. (author)

  14. Demonstration and determination of submicroscopic particles of uranium in environmental samples

    International Nuclear Information System (INIS)

    Sihelska, K.; Lorincik, J.; Sus, F.; Vesela, D.

    2016-01-01

    In this work laboratories of the Centrum vyzkumu Rez, Ltd are presented. Fission track analysis (FTA) is used for analysis of uranium in environmental samples. Treatment of samples for FTA is described and some results ar presented. The method of SIMS is used, too.

  15. GY SAMPLING THEORY IN ENVIRONMENTAL STUDIES 2: SUBSAMPLING ERROR MEASUREMENTS

    Science.gov (United States)

    Sampling can be a significant source of error in the measurement process. The characterization and cleanup of hazardous waste sites require data that meet site-specific levels of acceptable quality if scientifically supportable decisions are to be made. In support of this effort,...

  16. Lanthanide complexes as luminogenic probes to measure sulfide levels in industrial samples

    International Nuclear Information System (INIS)

    Thorson, Megan K.; Ung, Phuc; Leaver, Franklin M.; Corbin, Teresa S.; Tuck, Kellie L.; Graham, Bim; Barrios, Amy M.

    2015-01-01

    A series of lanthanide-based, azide-appended complexes were investigated as hydrogen sulfide-sensitive probes. Europium complex 1 and Tb complex 3 both displayed a sulfide-dependent increase in luminescence, while Tb complex 2 displayed a decrease in luminescence upon exposure to NaHS. The utility of the complexes for monitoring sulfide levels in industrial oil and water samples was investigated. Complex 3 provided a sensitive measure of sulfide levels in petrochemical water samples (detection limit ∼ 250 nM), while complex 1 was capable of monitoring μM levels of sulfide in partially refined crude oil. - Highlights: • Lanthanide–azide based sulfide sensors were synthesized and characterized. • The probes have excitation and emission profiles compatible with sulfide-contaminated samples from the petrochemical industry. • A terbium-based probe was used to measure the sulfide concentration in oil refinery wastewater. • A europium-based probe had compatibility with partially refined crude oil samples.

  17. Lanthanide complexes as luminogenic probes to measure sulfide levels in industrial samples

    Energy Technology Data Exchange (ETDEWEB)

    Thorson, Megan K. [Department of Medicinal Chemistry, University of Utah College of Pharmacy, Salt Lake City, UT 84108 (United States); Ung, Phuc [Monash Institute of Pharmaceutical Sciences, Monash University, Victoria 3052 (Australia); Leaver, Franklin M. [Water & Energy Systems Technology, Inc., Kaysville, UT 84037 (United States); Corbin, Teresa S. [Quality Services Laboratory, Tesoro Refining and Marketing, Salt Lake City, UT 84103 (United States); Tuck, Kellie L., E-mail: kellie.tuck@monash.edu [School of Chemistry, Monash University, Victoria 3800 (Australia); Graham, Bim, E-mail: bim.graham@monash.edu [Monash Institute of Pharmaceutical Sciences, Monash University, Victoria 3052 (Australia); Barrios, Amy M., E-mail: amy.barrios@utah.edu [Department of Medicinal Chemistry, University of Utah College of Pharmacy, Salt Lake City, UT 84108 (United States)

    2015-10-08

    A series of lanthanide-based, azide-appended complexes were investigated as hydrogen sulfide-sensitive probes. Europium complex 1 and Tb complex 3 both displayed a sulfide-dependent increase in luminescence, while Tb complex 2 displayed a decrease in luminescence upon exposure to NaHS. The utility of the complexes for monitoring sulfide levels in industrial oil and water samples was investigated. Complex 3 provided a sensitive measure of sulfide levels in petrochemical water samples (detection limit ∼ 250 nM), while complex 1 was capable of monitoring μM levels of sulfide in partially refined crude oil. - Highlights: • Lanthanide–azide based sulfide sensors were synthesized and characterized. • The probes have excitation and emission profiles compatible with sulfide-contaminated samples from the petrochemical industry. • A terbium-based probe was used to measure the sulfide concentration in oil refinery wastewater. • A europium-based probe had compatibility with partially refined crude oil samples.

  18. Technical Challenge and Demonstration of Advanced Solution Monitoring and Measurement System (ASMS)

    International Nuclear Information System (INIS)

    Takaya, A.; Mukai, Y.; Nakamura, H.; Hosoma, T.; Yoshimoto, K.; Tamura, T.; Iwamoto, T.

    2010-01-01

    JNFL and JAEA have collaboratively started to develop an Advanced Solution Measurement and monitoring System (ASMS) as a part of technical challenge intended for next generation safeguards NDA equipment. After we completed feasibility study by using small detectors, the second stage of ASMS has installed into PCDF tank located in a cell, and then tested and calibrated by Pu nitrate solution experimentally. There was no experience measuring around 50kg Pu inventory directly, so it was very challenging work. The conventional SMMS (Solution Monitoring and Measurement System) that is composed of precision manometers acquires density, level and temperature of solution, so that the sampling and analysis are essential to obtain the nuclear material amount in the tank. The SMMS has two weak points on verification and monitoring of the nuclear material flow and inventory; (1) Direct measurement of the inventory cannot be done, (2) Solution rework and reagent adjustment operation in actual plant will make miss-interpretation on the monitoring evaluation. The purpose of ASMS development is to establish quantitative plutonium mass measurement technique directly by NDA of high concentrated pure plutonium nitrate solution and monitoring capability for solution transfers in a process. The merits of ASMS are considered below; (1) Provide direct Pu measurement and continuous monitoring capability, (2) Eliminate sampling and analysis at IIV, (3) Reduce unmeasured inventory. The target of the measurement uncertainty of ASMS is set less than 6% (1sigma) which is equivalent to meet the detection level of the partial defect at IIV by NDA. Known-alpha coincidence counting technique is applied to the ASMS, which is similar to the NDAs for MOX powder as a principle measurement technique. Especially, three following points are key techniques to establish ASMS. (1) Pre-determination of plutonium isotopic composition because it impacts alpha and rho-zero values to obtain multiplication

  19. A nuclear radiation multi-parameter measurement system based on pulse-shape sampling

    International Nuclear Information System (INIS)

    Qiu Xiaolin; Fang Guoming; Xu Peng; Di Yuming

    2007-01-01

    In this paper, A nuclear radiation multi-parameter measurement system based on pulse-shape sampling is introduced, including the system's characteristics, composition, operating principle, experiment data and analysis. Compared with conventional nuclear measuring apparatus, it has some remarkable advantages such as the synchronous detection using multi-parameter measurement in the same measurement platform and the general analysis of signal data by user-defined program. (authors)

  20. Absolute measurement of the isotopic ratio of a water sample with very low deuterium content

    International Nuclear Information System (INIS)

    Hagemann, R.; Nief, G.; Roth, E.

    1968-01-01

    The presence of H 3+ ions which are indistinguishable from HD + ions presents the principal difficulty encountered in the measurement of isotopic ratios of water samples with very low deuterium contents using a mass spectrometer. Thus, when the sample contains no deuterium, the mass spectrometer does not indicate zero. By producing, in situ, from the sample to be measured, water vapor with an isotopic ratio very close to zero using a small distilling column, this difficulty is overcome. This column, its operating parameters, as well as the way in which the measurements are made are described. An arrangement is employed in which the isotopic ratios can be measured with a sensitivity better than 0.01 x 10 -6 . The method is applied to the determination of the isotopic ratios of three low deuterium content water samples. The results obtained permit one to assign to the sample with the lowest deuterium content an absolute value equal to 1.71 ± 0.03 ppm. This water sample is a primary standard from which is determined the isotopic ratio of a natural water sample which serves as the laboratory standard. (author) [fr

  1. Authentication Assurance Level Application to the Inventory Sampling Measurement System

    International Nuclear Information System (INIS)

    Devaney, Mike M.; Kouzes, Richard T.; Hansen, Randy R.; Geelhood, Bruce D.

    2001-01-01

    This document concentrates on the identification of a standardized assessment approach for the verification of security functionality in specific equipment, the Inspection Sampling Measurement System (ISMS) being developed for MAYAK. Specifically, an Authentication Assurance Level 3 is proposed to be reached in authenticating the ISMS

  2. Measuring the gut microbiome in birds: Comparison of faecal and cloacal sampling.

    Science.gov (United States)

    Videvall, Elin; Strandh, Maria; Engelbrecht, Anel; Cloete, Schalk; Cornwallis, Charlie K

    2018-05-01

    The gut microbiomes of birds and other animals are increasingly being studied in ecological and evolutionary contexts. Numerous studies on birds and reptiles have made inferences about gut microbiota using cloacal sampling; however, it is not known whether the bacterial community of the cloaca provides an accurate representation of the gut microbiome. We examined the accuracy with which cloacal swabs and faecal samples measure the microbiota in three different parts of the gastrointestinal tract (ileum, caecum, and colon) using a case study on juvenile ostriches, Struthio camelus, and high-throughput 16S rRNA sequencing. We found that faeces were significantly better than cloacal swabs in representing the bacterial community of the colon. Cloacal samples had a higher abundance of Gammaproteobacteria and fewer Clostridia relative to the gut and faecal samples. However, both faecal and cloacal samples were poor representatives of the microbial communities in the caecum and ileum. Furthermore, the accuracy of each sampling method in measuring the abundance of different bacterial taxa was highly variable: Bacteroidetes was the most highly correlated phylum between all three gut sections and both methods, whereas Actinobacteria, for example, was only strongly correlated between faecal and colon samples. Based on our results, we recommend sampling faeces, whenever possible, as this sample type provides the most accurate assessment of the colon microbiome. The fact that neither sampling technique accurately portrayed the bacterial community of the ileum nor the caecum illustrates the difficulty in noninvasively monitoring gut bacteria located further up in the gastrointestinal tract. These results have important implications for the interpretation of avian gut microbiome studies. © 2017 John Wiley & Sons Ltd.

  3. [Evaluation on intervention measures of comprehensive control for parasitic diseases in demonstration plot of Xiangyun County].

    Science.gov (United States)

    Wen-Juan, Li; Shao-Rong, Chen; Yan-Hong, Li; Wen, Fang; Chun-Rong, Ke; Li-Bo, Wang

    2011-10-01

    To evaluate the effect of comprehensive intervention measures to control and prevent parasitic diseases in the demonstration plot of Xiangyun County, so as to provide the evidence for establishing appropriate measures of parasitic diseases control and prevention. The baseline data of soil-transmitted nematode infections were obtained in 2006. A series of intervention measures, including health education, deworming, drinking water improvement,latrine improvement, and environment reconstruction, were performed for three years and the effect of the comprehensive intervention measures was evaluated by the national expert group in 2009. The awareness rate of parasitic disease knowledge of residents in 2009 (86.96%) was significantly higher than that in 2006 (35.20%) (Chi2 = 122.95, P transmitted nematode infections, the infection rates of Ascaris lumbricoides in both 2006 and 2009 were the highest and the rates were 18.74% and 2.08%, respectively. In the demonstration plots for parasitic diseases control and prevention of Xiangyun County, the effect of the comprehensive intervention measures which take health education as the forerunner and give priority to control source of parasite infection is remarkable. The measures implemented can achieve the purpose to reduce the infection rates of parasites and improve human health.

  4. Method of measuring the disinteration rate of beta-emitting radionuclide in a liquid sample

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1977-01-01

    A method of measuring the disintegration rate of a beta-emitting radionuclide in a liquid sample by counting at least two differently quenched versions of the sample is described. In each counting operation the sample is counted in the presence of and in the absence of a standard radioactive source. A pulse height (PH) corresponding to a unique point on the pulse height spectrum generated in the presence of the standard is determined. A zero threshold sample count rate (CPM) is derived by counting the sample once in a counting window having a zero threshold lower limit. Normalized values of the measured pulse heights (PH) are developed and correlated with the corresponding pulse counts (CPM) to determine the pulse count for a normalized pulse height value of zero and hence the sample disintegration rate

  5. Measurement of technetium-99 in Marshall Islands soil samples by ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Tagami, K. E-mail: k_tagami@nirs.go.jp; Uchida, S.; Hamilton, T.; Robison, W

    2000-07-15

    Extraction techniques for recovery of technetium-99 ({sup 99}Tc) for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for {sup 99}Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the {sup 99}Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The {sup 99}Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq g{sup -1} dry weight (dw). The limit of detection for {sup 99}Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq g{sup -1} dw under standard operating conditions.

  6. Measuring c-quark polarization in W+c samples at ATLAS and CMS

    CERN Document Server

    Kats, Yevgeny

    2016-01-01

    The process $pp \\to W^-c$ produces polarized charm quarks. The polarization is expected to be partly retained in $\\Lambda_c$ baryons when those form in the $c$-quark hadronization. We argue that it will likely be possible for ATLAS and CMS to measure the $\\Lambda_c$ polarization in the $W$+$c$ samples in Run 2 of the LHC. This can become the first measurement ever of a longitudinal polarization of charm quarks. Its results will provide a unique input to the understanding of polarization transfer in fragmentation. They will also allow applying the same measurement technique to other (e.g., new physics) samples of charm quarks in which the polarization is a priori unknown. The proposed analysis is similar to the ATLAS and CMS measurements of the $W$+$c$ cross section in the 7 TeV run that used reconstructed $D$-meson decays for charm tagging.

  7. Development of an automatic sampling device for the continuous measurement of atmospheric carbonyls compounds

    International Nuclear Information System (INIS)

    Perraud, V.

    2007-12-01

    Two sampling strategies were studied to develop an automatic instrument for the continuous measurement of atmospheric carbonyl compounds. Because of its specificity towards carbonyls compounds, sampling by using a transfer of gaseous phase in a liquid phase associated with a simultaneous chemical derivatization of the trapped compounds was first studied. However, this method do not allow a quantitative sampling of all studied carbonyl compounds, nor a continuous measurement in the field. To overcome the difficulties, a second strategy was investigated: the cryogenic adsorption onto solid adsorbent followed by thermodesorption and a direct analysis by GC/MS. Collection efficiency using different solid adsorbents was found greater than 95% for carbonyl compounds consisting of 1 to 7 carbons. This work is a successful first step towards the realization of the automatic sampling device for a continuous measurement of atmospheric carbonyls compounds. (author)

  8. Accounting for randomness in measurement and sampling in studying cancer cell population dynamics.

    Science.gov (United States)

    Ghavami, Siavash; Wolkenhauer, Olaf; Lahouti, Farshad; Ullah, Mukhtar; Linnebacher, Michael

    2014-10-01

    Knowing the expected temporal evolution of the proportion of different cell types in sample tissues gives an indication about the progression of the disease and its possible response to drugs. Such systems have been modelled using Markov processes. We here consider an experimentally realistic scenario in which transition probabilities are estimated from noisy cell population size measurements. Using aggregated data of FACS measurements, we develop MMSE and ML estimators and formulate two problems to find the minimum number of required samples and measurements to guarantee the accuracy of predicted population sizes. Our numerical results show that the convergence mechanism of transition probabilities and steady states differ widely from the real values if one uses the standard deterministic approach for noisy measurements. This provides support for our argument that for the analysis of FACS data one should consider the observed state as a random variable. The second problem we address is about the consequences of estimating the probability of a cell being in a particular state from measurements of small population of cells. We show how the uncertainty arising from small sample sizes can be captured by a distribution for the state probability.

  9. Transport measurements in superconductors: critical current of granular high TC ceramic superconductor samples

    International Nuclear Information System (INIS)

    Passos, W.A.C.

    2016-01-01

    This work presents a method to obtain critical current of granular superconductors. We have carried out transport measurements (ρxT curves and VxI curves) in a YBa_2Cu_3O_7_-_δ sample to determine critical current density of it. Some specimens reveal a 'semiconductor-like' behavior (electrical resistivity decreases with increasing temperatures above critical temperature T_c of material) competing with superconductor behavior. Due to high granular fraction of the sample, these competition is clearly noted in ρxT curves. Measurements carried out from 0 to 8500 Oe of applied field show the same behavior, and the critical current density of the samples is shown. (author)

  10. Assessment of molecular markers demonstrates concordance between samples acquired via stereotactic biopsy and open craniotomy in both anaplastic astrocytomas and glioblastomas.

    Science.gov (United States)

    Gessler, Florian; Baumgarten, Peter; Bernstock, Joshua D; Harter, Patrick; Lescher, Stephanie; Senft, Christian; Seifert, Volker; Marquardt, Gerhard; Weise, Lutz

    2017-06-01

    The classification, treatment and prognosis of high-grade gliomas has been shown to correlate with the expression of molecular markers (e.g. MGMT promotor methylation and IDH1 mutations). Acquisition of tumor samples may be obtained via stereotactic biopsy or open craniotomy. Between the years 2009 and 2013, 22 patients initially diagnosed with HGGs via stereotactic biopsy, that ultimately underwent open craniotomy for resection of their tumor were prospectively included in an institutional glioma database. MGMT promotor analysis was performed using methylation-specific (MS)-PCR and IDH1R132H mutation analysis was performed using immunohistochemistry. Three patients (13.7%) exhibited IDH1R132H mutations in samples obtained via stereotactic biopsy. Tissue derived from stereotaxic biopsy was demonstrated to have MGMT promotor methylation in ten patients (45.5%), while a non-methylated MGMT promotor was demonstrated in ten patients (45.5%); inconclusive results were obtained for the remaining two patients (9%) within our cohort. The initial histologic grading, IDH1R132H mutation and MGMT promotor methylation results were confirmed using samples obtained during open craniotomy in all but one patient; here inconclusive MGMT promotor analysis was obtained in contrast to that which was obtained via stereotactic biopsy. Tumor samples acquired via stereotactic biopsy provide accurate information with regard to clinically relevant molecular markers that have been shown to impact patient care decisions. The profile of markers analyzed in our cohort was nearly concordant between those samples obtained via stereotactic biopsy or open craniotomy thereby suggesting that clinical decisions may be based on the molecular profile of the tumor samples obtained via stereotactic biopsy.

  11. Evaluation of laser-induced breakdown spectroscopy (LIBS) for measurement of silica on filter samples of coal dust.

    Science.gov (United States)

    Stipe, Christopher B; Miller, Arthur L; Brown, Jonathan; Guevara, Edward; Cauda, Emanuele

    2012-11-01

    Airborne silica dust (quartz) is common in coal mines and represents a respiratory hazard that can lead to silicosis, a potentially fatal lung disease. With an eye toward developing a portable monitoring device for rapid analysis of silica dust, laser-induced breakdown spectroscopy (LIBS) was used to quantify quartz in coal dust samples collected on filter media. Pure silica (Min-U-Sil™ 5), Georgia kaolin, and Pittsburgh-4 and Illinois-6 coal dusts were deposited separately and at multiple mass loadings onto 37-mm polyvinylchloride (PVC) filters. LIBS-generated silicon emission was monitored at 288.16 nm, and non-silica contributions to that signal from kaolinite were removed by simultaneously detecting aluminum. Measurements of the four samples were used to calculate limits of detection (LOD) for silicon and aluminum of approximately 0.08 μg/cm(2) and 0.05 μg/cm(2), respectively (corresponding to 0.16 μg/cm(2) and 0.20 μg/cm(2) for silica and kaolinite, respectively). Relative errors of prediction are around 10%. Results demonstrate that LIBS can dependably quantify silica on filter samples of coal dust and confirm that accurate quantification can be achieved for very lightly loaded samples, which supports the potential application of LIBS for rapid, in-field monitoring.

  12. Feasibility Demonstration of Exciplex Fluorescence Measurements in Evaporating Laminar Sprays of Diesel Fuel

    Science.gov (United States)

    2011-05-15

    code) 1 FEASIBILITY DEMONSTRATION OF EXCIPLEX FLUORESCENCE MEASUREMENTS IN EVAPORATING LAMINAR SPRAYS OF DIESEL FUEL Final Technical Report Grant...fluorescence is found to increase with temperature up to 538 K and then declines. Fluorescence from the liquid phase, i.e. the exciplex (Naphthalene+TMPD...to have as well characterized a description of the spray environment and assess conclusively the potential of the exciplex approach for more

  13. CHARACTERIZATION AND ALUMINUM DISSOLUTION DEMONSTRATION WITH A 3 LITER TANK 51H SAMPLE

    International Nuclear Information System (INIS)

    Hay, M; John Pareizs, J; Cj Bannochie, C; Michael Stone, M; Damon Click, D; Daniel McCabe, D

    2008-01-01

    A 3-liter sludge slurry sample was sent to SRNL for demonstration of a low temperature aluminum dissolution process. The sludge was characterized before and after the aluminum dissolution. Post aluminum dissolution sludge settling and the stability of the decanted supernate were also observed. The characterization of the as-received 3-liter sample of Tank 51H sludge slurry shows a typical high aluminum HM sludge. The XRD analysis of the dried solids indicates Boehmite is the predominant crystalline form of aluminum in the sludge solids. However, amorphous phases of aluminum present in the sludge would not be identified using this analytical technique. The low temperature (55 C) aluminum dissolution process was effective at dissolving aluminum from the sludge. Over the three week test, ∼42% of the aluminum was dissolved out of the sludge solids. The process appears to be selective for aluminum with no other metals dissolving to any appreciable extent. At the termination of the three week test, the aluminum concentration in the supernate had not leveled off indicating more aluminum could be dissolved from the sludge with longer contact times or higher temperatures. The slow aluminum dissolution rate in the test may indicate the dissolution of the Boehmite form of aluminum however; insufficient kinetic data exists to confirm this hypothesis. The aluminum dissolution process appears to have minimal impact on the settling rate of the post aluminum dissolution sludge. However, limited settling data were generated during the test to quantify the effects. The sludge settling was complete after approximately twelve days. The supernate decanted from the settled sludge after aluminum dissolution appears stable and did not precipitate aluminum over the course of several months. A mixture of the decanted supernate with Tank 11 simulated supernate was also stable with respect to precipitation

  14. Assessment of glomerular filtration rate measurement with plasma sampling: a technical review.

    Science.gov (United States)

    Murray, Anthony W; Barnfield, Mark C; Waller, Michael L; Telford, Tania; Peters, A Michael

    2013-06-01

    This article reviews available radionuclide-based techniques for glomerular filtration rate (GFR) measurement, focusing on clinical indications for GFR measurement, ideal GFR radiopharmaceutical tracer properties, and the 2 most common tracers in clinical use. Methods for full, 1-compartment, and single-sample renal clearance characterization are discussed. GFR normalization and the role of GFR measurement in chemotherapy dosing are also considered.

  15. Climatologies from satellite measurements: the impact of orbital sampling on the standard error of the mean

    Directory of Open Access Journals (Sweden)

    M. Toohey

    2013-04-01

    Full Text Available Climatologies of atmospheric observations are often produced by binning measurements according to latitude and calculating zonal means. The uncertainty in these climatological means is characterised by the standard error of the mean (SEM. However, the usual estimator of the SEM, i.e., the sample standard deviation divided by the square root of the sample size, holds only for uncorrelated randomly sampled measurements. Measurements of the atmospheric state along a satellite orbit cannot always be considered as independent because (a the time-space interval between two nearest observations is often smaller than the typical scale of variations in the atmospheric state, and (b the regular time-space sampling pattern of a satellite instrument strongly deviates from random sampling. We have developed a numerical experiment where global chemical fields from a chemistry climate model are sampled according to real sampling patterns of satellite-borne instruments. As case studies, the model fields are sampled using sampling patterns of the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS and Atmospheric Chemistry Experiment Fourier-Transform Spectrometer (ACE-FTS satellite instruments. Through an iterative subsampling technique, and by incorporating information on the random errors of the MIPAS and ACE-FTS measurements, we produce empirical estimates of the standard error of monthly mean zonal mean model O3 in 5° latitude bins. We find that generally the classic SEM estimator is a conservative estimate of the SEM, i.e., the empirical SEM is often less than or approximately equal to the classic estimate. Exceptions occur only when natural variability is larger than the random measurement error, and specifically in instances where the zonal sampling distribution shows non-uniformity with a similar zonal structure as variations in the sampled field, leading to maximum sensitivity to arbitrary phase shifts between the sample distribution and

  16. Effect of the sample matrix on measurement uncertainty in X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Morgenstern, P.; Brueggemann, L.; Wennrich, R.

    2005-01-01

    The estimation of measurement uncertainty, with reference to univariate calibration functions, is discussed in detail in the Eurachem Guide 'Quantifying Uncertainty in Analytical Measurement'. The adoption of these recommendations to quantitative X-ray fluorescence analysis (XRF) involves basic problems which are above all due to the strong influence of the sample matrix on the analytical response. In XRF-analysis, the proposed recommendations are consequently applicable only to the matrix corrected response. The application is also restricted with regard to both the matrices and analyte concentrations. In this context the present studies are aimed at the problems to predict measurement uncertainty also with reference to more variable sample compositions. The corresponding investigations are focused on the use of the intensity of the Compton scattered tube line as an internal standard to assess the effect of the individual sample matrix on the analytical response relatively to a reference matrix. Based on this concept the estimation of the measurement uncertainty of an analyte presented in an unknown specimen can be predicted in consideration of the data obtained under defined matrix conditions

  17. Measurement of density distribution of a cracking catalyst in experimental riser with a sampling procedure for gamma ray tomography

    International Nuclear Information System (INIS)

    Dantas, C.C.; Melo, S.B.; Oliveira, E.F.; Simoes, F.P.M.; Santos, M.G. dos; Santos, V.A. dos

    2008-01-01

    By scanning a riser the number of the gamma ray trajectories and the beam width involve temporal, spatial and density resolutions as they are closely correlated parameters. Therefore, evaluation of parameters and their interaction quantification, certainly, are required in the imaging process. Measuring the density distribution of the catalyst from the FCC - fluid cracking catalytic process in an experimental riser in single beam tomographic system, density resolution is evaluated and correlated with spatial resolution. The beam width Δs inside riser is measured and a criterion for determining spatial resolution is proposed. Experiments are carried out to demonstrate resolution effects of three Δs values: 3.30 x 10 -3 , 6.20 x 10 -3 and 12.00 x 10 -3 m. The gamma beam profile is modeled and a sampling rate according to Nyquist criterion is analyzed. The 4.3%, 8.1% and 15.6% ratios of Δs/R to internal riser radius are correlated to counting time in the sampling procedure. Results are discussed by comparison with values from literature

  18. Activation measurements for thermal neutrons. Part G. Natural 36Cl production in mineral samples

    International Nuclear Information System (INIS)

    Nolte, Eckehart; Huber, Thomas; Lazarev, Vitali; Ruehm, Werner; Kato, Kazuo; Schultz, Ludolf

    2005-01-01

    In the present paper, a method was developed to calculate the contribution of natural in situ production of 36 Cl in mineral samples to the 36 Cl signal induced by the neutrons from the Hiroshima bomb. Parameters used in the calculations include local erosion rates, lithospheric depth, and elemental composition for each investigated sample. It has been shown that the calculations agree within their uncertainties with 36 Cl values measured by means of accelerator mass spectrometry, in granite samples from quarries with known locations. Both calculations and measurements suggest typical 36 Cl/Cl ratios of about 10 -13 in mineral samples. (J.P.N.)

  19. Chemical Composition Measurements of LAWA44 Glass Samples

    Energy Technology Data Exchange (ETDEWEB)

    Fox, K. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Edwards, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Riley, W. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-11-15

    DOE is building the Hanford Tank Waste Treatment and Immobilization Plant (WTP) at the Hanford Site in Washington to remediate 55 million gallons of radioactive waste that is temporarily stored in 177 underground tanks. Both low-activity and high-level wastes will then be vitrified into borosilicate glass using Joule-heated ceramic melters. Efforts are being made to increase the loading of Hanford tank wastes in the glass. One area of work is enhancing waste glass composition/property models and broadening the compositional regions over which those models are applicable. In this report, the Savannah River National Laboratory provides chemical analysis results for several samples of a simulated low-activity waste glass, LAWA44, provided by the Pacific Northwest National Laboratory as part of an ongoing development task. The measured chemical composition data are reported and compared with the targeted values for each component for each glass. A detailed review showed no indications of errors in the preparation or measurement of the study glasses. All of the measured sums of oxides for the study glasses fell within the interval of 97.9 to 102.6 wt %, indicating acceptable recovery of the glass components. Comparisons of the targeted and measured chemical compositions showed that the measured values for the glasses met the targeted concentrations within 10% for those components present at more than 5 wt %. It was noted that the measured B2O3 concentrations are somewhat above the targeted values for the study glasses. No obvious trends were observed with regard to the multiple melting steps used to prepare the study glasses, indicating that any potential effects of volatility were below measurable thresholds.

  20. Effects of holding time and measurement error on culturing Legionella in environmental water samples.

    Science.gov (United States)

    Flanders, W Dana; Kirkland, Kimberly H; Shelton, Brian G

    2014-10-01

    Outbreaks of Legionnaires' disease require environmental testing of water samples from potentially implicated building water systems to identify the source of exposure. A previous study reports a large impact on Legionella sample results due to shipping and delays in sample processing. Specifically, this same study, without accounting for measurement error, reports more than half of shipped samples tested had Legionella levels that arbitrarily changed up or down by one or more logs, and the authors attribute this result to shipping time. Accordingly, we conducted a study to determine the effects of sample holding/shipping time on Legionella sample results while taking into account measurement error, which has previously not been addressed. We analyzed 159 samples, each split into 16 aliquots, of which one-half (8) were processed promptly after collection. The remaining half (8) were processed the following day to assess impact of holding/shipping time. A total of 2544 samples were analyzed including replicates. After accounting for inherent measurement error, we found that the effect of holding time on observed Legionella counts was small and should have no practical impact on interpretation of results. Holding samples increased the root mean squared error by only about 3-8%. Notably, for only one of 159 samples, did the average of the 8 replicate counts change by 1 log. Thus, our findings do not support the hypothesis of frequent, significant (≥= 1 log10 unit) Legionella colony count changes due to holding. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. 169 Résumé Abstract Measure of uranium in some samples of ...

    African Journals Online (AJOL)

    youness

    puits et par activation neutronique. Mots-clés : Uranium, Radioactivité naturelle, Coraux, Coquilles de mollusques, lichens, travertins, Carbonates. Abstract. Measure of uranium in some samples of natural deposits in Morocco: environmental implications. In this work, we report the measurement results of uranium content in.

  2. Phase 1 Characterization sampling and analysis plan West Valley demonstration project.

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R. L. (Environmental Science Division)

    2011-06-30

    The Phase 1 Characterization Sampling and Analysis Plan (CSAP) provides details about environmental data collection that will be taking place to support Phase 1 decommissioning activities described in the Phase 1 Decommissioning Plan for the West Valley Demonstration Project, Revision 2 (Phase I DP; DOE 2009). The four primary purposes of CSAP data collection are: (1) pre-design data collection, (2) remedial support, (3) post-remediation status documentation, and (4) Phase 2 decision-making support. Data collection to support these four main objectives is organized into two distinct data collection efforts. The first is data collection that will take place prior to the initiation of significant Phase 1 decommissioning activities (e.g., the Waste Management Area [WMA] 1 and WMA 2 excavations). The second is data collection that will occur during and immediately after environmental remediation in support of remediation activities. Both data collection efforts have a set of well-defined objectives that encompass the data needs of the four main CSAP data collection purposes detailed in the CSAP. The main body of the CSAP describes the overall data collection strategies that will be used to satisfy data collection objectives. The details of pre-remediation data collection are organized by WMA. The CSAP contains an appendix for each WMA that describes the details of WMA-specific pre-remediation data collection activities. The CSAP is intended to expand upon the data collection requirements identified in the Phase 1 Decommissioning Plan. The CSAP is intended to tightly integrate with the Phase 1 Final Status Survey Plan (FSSP). Data collection described by the CSAP is consistent with the FSSP where appropriate and to the extent possible.

  3. Adaptive Sampling based 3D Profile Measuring Method for Free-Form Surface

    Science.gov (United States)

    Duan, Xianyin; Zou, Yu; Gao, Qiang; Peng, Fangyu; Zhou, Min; Jiang, Guozhang

    2018-03-01

    In order to solve the problem of adaptability and scanning efficiency of the current surface profile detection device, a high precision and high efficiency detection approach is proposed for surface contour of free-form surface parts based on self- adaptability. The contact mechanical probe and the non-contact laser probe are synthetically integrated according to the sampling approach of adaptive front-end path detection. First, the front-end path is measured by the non-contact laser probe, and the detection path is planned by the internal algorithm of the measuring instrument. Then a reasonable measurement sampling is completed according to the planned path by the contact mechanical probe. The detection approach can effectively improve the measurement efficiency of the free-form surface contours and can simultaneously detect the surface contours of unknown free-form surfaces with different curvatures and even different rate of curvature. The detection approach proposed in this paper also has important reference value for free-form surface contour detection.

  4. IFCC guideline for sampling, measuring and reporting ionized magnesium in plasma

    DEFF Research Database (Denmark)

    Rayana, M.C. Ben; Burnett, R.W.; Covington, A.K.

    2008-01-01

    Analyzers with ion-selective electrodes (ISEs) for ionized magnesium (iMg) should yield comparable and unbiased results for iMg. This IFCC guideline on sampling, measuring and reporting iMg in plasma provides a prerequisite to achieve this goal [in this document, "plasma" refers to circulating...... plasma and the forms in which it is sampled, namely the plasma phase of anticoagulated whole blood (or "blood"), plasma separated from blood cells, or serum]. The guideline recommends measuring and reporting ionized magnesium as a substance concentration relative to the substance concentration...... of magnesium in primary aqueous calibrants with magnesium, sodium, and calcium chloride of physiological ionic strength. The recommended name is "the concentration of ionized magnesium in plasma". Based on this guideline, results will be approximately 3% higher than the true substance concentration and 4...

  5. Achievement Motivation Revisited: New Longitudinal Data to Demonstrate Its Predictive Power

    Science.gov (United States)

    Hustinx, Paul W. J.; Kuyper, Hans; van der Werf, Margaretha P. C.; Dijkstra, Pieternel

    2009-01-01

    During recent decades, the classical one-dimensional concept of achievement motivation has become less popular among motivation researchers. This study aims to revive the concept by demonstrating its predictive power using longitudinal data from two cohort samples, each with 20,000 Dutch secondary school students. Two measures of achievement…

  6. Chemical Hygiene Plan for Onsite Measurement and Sample Shipping Facility Activities

    International Nuclear Information System (INIS)

    Price, W.H.

    1998-01-01

    This chemical hygiene plan presents the requirements established to ensure the protection of employee health while performing work in mobile laboratories, the sample shipping facility, and at the onsite radiological counting facility. This document presents the measures to be taken to promote safe work practices and to minimize worker exposure to hazardous chemicals. Specific hazardous chemicals present in the mobile laboratories, the sample shipping facility, and in the radiological counting facility are presented in Appendices A through G

  7. Reactor-vessel-sectioning demonstration

    International Nuclear Information System (INIS)

    Lundgren, R.A.

    1981-09-01

    A technical demonstration was successfully completed of simulated reactor vessel sectioning using the combined techniques of air arc gouging and flame cutting. A 4-ft x 3-ft x 9-in. thick sample was fabricated of A36 carbon steel to simulate a reactor vessel wall. A 1/4-in. layer of stainless steel (SS) was tungsten inert gas (TIG)-welded to the carbon steel. Several techniques were considered to section the simulated reactor vessel; air arc gouging was selected to penetrate the stainless steel, and flame cutting was selected to sever the carbon steel. Three sectioning operations were demonstrated. For all three, the operating parameters were the same; but the position of the sample was varied. For the first cut, the sample was placed in a horizontal position, and it was successfully severed from the SS side. For the second cut, the sample was turned over and cut from the carbon steel side. Cutting from the carbon steel side has the advantages of cost reduction

  8. Reactivity and neutron emission measurements of highly burnt PWR fuel rod samples

    International Nuclear Information System (INIS)

    Murphy, M.F.; Jatuff, F.; Grimm, P.; Seiler, R.; Brogli, R.; Meier, G.; Berger, H.-D.; Chawla, R.

    2006-01-01

    Fuel rods with burnup values beyond 50 GWd/t are characterised by relatively large amounts of fission products and a high abundance of major and minor actinides. Of particular interest is the change in the reactivity of the fuel as a function of burnup and the capability of modern codes to predict this change. In addition, the neutron emission from burnt fuel has important implications for the design of transport and storage facilities. Measurements have been made of the reactivity effects and the neutron emission rates of highly burnt uranium oxide and mixed oxide fuel rod samples coming from a pressurised water reactor (PWR). The reactivity measurements have been made in a PWR lattice in the PROTEUS zero-energy reactor moderated in turn with: water, a water and heavy water mixture and water containing boron. A combined transport flask and sample changer was used to insert the 400 mm long burnt fuel rod segments into the reactor. Both control rod compensation and reactor period methods were used to determine the reactivities of the samples. For the range of burnup values investigated, an interesting exponential relationship has been found between the neutron emission rate and the measured reactivity

  9. Novel system using microliter order sample volume for measuring arterial radioactivity concentrations in whole blood and plasma for mouse PET dynamic study.

    Science.gov (United States)

    Kimura, Yuichi; Seki, Chie; Hashizume, Nobuya; Yamada, Takashi; Wakizaka, Hidekatsu; Nishimoto, Takahiro; Hatano, Kentaro; Kitamura, Keishi; Toyama, Hiroshi; Kanno, Iwao

    2013-11-21

    This study aimed to develop a new system, named CD-Well, for mouse PET dynamic study. CD-Well allows the determination of time-activity curves (TACs) for arterial whole blood and plasma using 2-3 µL of blood per sample; the minute sample size is ideal for studies in small animals. The system has the following merits: (1) measures volume and radioactivity of whole blood and plasma separately; (2) allows measurements at 10 s intervals to capture initial rapid changes in the TAC; and (3) is compact and easy to handle, minimizes blood loss from sampling, and delay and dispersion of the TAC. CD-Well has 36 U-shaped channels. A drop of blood is sampled into the opening of the channel and stored there. After serial sampling is completed, CD-Well is centrifuged and scanned using a flatbed scanner to define the regions of plasma and blood cells. The length measured is converted to volume because the channels have a precise and uniform cross section. Then, CD-Well is exposed to an imaging plate to measure radioactivity. Finally, radioactivity concentrations are computed. We evaluated the performance of CD-Well in in vitro measurement and in vivo (18)F-fluorodeoxyglucose and [(11)C]2-carbomethoxy-3β-(4-fluorophenyl) tropane studies. In in vitro evaluation, per cent differences (mean±SE) from manual measurement were 4.4±3.6% for whole blood and 4.0±3.5% for plasma across the typical range of radioactivity measured in mouse dynamic study. In in vivo studies, reasonable TACs were obtained. The peaks were captured well, and the time courses coincided well with the TAC derived from PET imaging of the heart chamber. The total blood loss was less than 200 µL, which had no physiological effect on the mice. CD-Well demonstrates satisfactory performance, and is useful for mouse PET dynamic study.

  10. Identification and estimation of nonlinear models using two samples with nonclassical measurement errors

    KAUST Repository

    Carroll, Raymond J.

    2010-05-01

    This paper considers identification and estimation of a general nonlinear Errors-in-Variables (EIV) model using two samples. Both samples consist of a dependent variable, some error-free covariates, and an error-prone covariate, for which the measurement error has unknown distribution and could be arbitrarily correlated with the latent true values; and neither sample contains an accurate measurement of the corresponding true variable. We assume that the regression model of interest - the conditional distribution of the dependent variable given the latent true covariate and the error-free covariates - is the same in both samples, but the distributions of the latent true covariates vary with observed error-free discrete covariates. We first show that the general latent nonlinear model is nonparametrically identified using the two samples when both could have nonclassical errors, without either instrumental variables or independence between the two samples. When the two samples are independent and the nonlinear regression model is parameterized, we propose sieve Quasi Maximum Likelihood Estimation (Q-MLE) for the parameter of interest, and establish its root-n consistency and asymptotic normality under possible misspecification, and its semiparametric efficiency under correct specification, with easily estimated standard errors. A Monte Carlo simulation and a data application are presented to show the power of the approach.

  11. Design of an automatic sample changer for the measurement of neutron flux by gamma spectrometry

    International Nuclear Information System (INIS)

    Gago, Javier; Bruna, Ruben; Baltuano, Oscar; Montoya, Eduardo; Descreaux, Killian

    2014-01-01

    This paper presents calculus, selection and components design for the construction of an automatic system in order to measure neutron flux in a working nuclear reactor by the gamma spectrometry technique using samples irradiated on the RP-10 nucleus. This system will perform the measurement of interchanging 100 samples in a programed and automatic way, reducing operation time by the user and obtaining more accurate measures. (authors).

  12. Demonstration of inaccuracy of QTL mapping due to sampling error€

    African Journals Online (AJOL)

    Bertrand Collard

    2012-06-12

    Jun 12, 2012 ... finding in simple terms so that findings and implications can be easily ... While sampling from the true populations for n = 94 and n =190, individual mapping .... Overview of QTL mapping experimental design. Four true ...

  13. Effect of granulation of geological samples in neutron transport measurements

    International Nuclear Information System (INIS)

    Woznicka, Urszula; Drozdowicz, Krzysztof; Gabanska, Barbara; Krynicka, Ewa; Igielski, Andrzej

    2001-01-01

    The thermal neutron absorption cross section is one of the parameters describing the transport of thermal neutrons in a medium. Theoretical descriptions and experiments which determine the absorption cross section have a wide literature for homogeneous media. The situation comes true e.g. for fluids or amorphous solids. There are many other media which should be treated as heterogeneous. Among others - geological materials. The material heterogeneity for the thermal neutron transport in a considered volume is understood here as an existence of many small regions which differ significantly in their macroscopic neutron diffusion parameters (defined by the absorption and transport cross sections). The final difference, which influences the neutron transport, comes from a combination of the absolute differences between the parameters and of sizes of regions (related to the neutron mean free paths). A rock can be naturally heterogeneous in the above meaning. Besides, it can happen that a preparation of the rock sample for a neutron measurement can increase its natural heterogeneity. (For example, when the rock material is crushed and the measured sample consists of the obtained grains). The question is which granulation is allowed to treat the sample material as still homogeneous, and from which size of the rock grains we have to consider a two-component medium. It has been experimentally proved that the effective absorption of thermal neutrons in a heterogeneous two-component material can significantly differ from the absorption in a homogeneous one which consists of the same elements. The final effect is dependent on a few factors: the macroscopic absorption cross sections of the components, their total mass contributions, and the size of the grains. The ratio of the effective absorption cross section of the heterogeneous material to the cross section of the equivalent homogeneous, is a measure of the heterogeneity effect on the thermal neutron absorption

  14. Demonstration of Detection and Ranging Using Solvable Chaos

    Science.gov (United States)

    Corron, Ned J.; Stahl, Mark T.; Blakely, Jonathan N.

    2013-01-01

    Acoustic experiments demonstrate a novel approach to ranging and detection that exploits the properties of a solvable chaotic oscillator. This nonlinear oscillator includes an ordinary differential equation and a discrete switching condition. The chaotic waveform generated by this hybrid system is used as the transmitted waveform. The oscillator admits an exact analytic solution that can be written as the linear convolution of binary symbols and a single basis function. This linear representation enables coherent reception using a simple analog matched filter and without need for digital sampling or signal processing. An audio frequency implementation of the transmitter and receiver is described. Successful acoustic ranging measurements are presented to demonstrate the viability of the approach.

  15. Four-point probe measurements using current probes with voltage feedback to measure electric potentials

    Science.gov (United States)

    Lüpke, Felix; Cuma, David; Korte, Stefan; Cherepanov, Vasily; Voigtländer, Bert

    2018-02-01

    We present a four-point probe resistance measurement technique which uses four equivalent current measuring units, resulting in minimal hardware requirements and corresponding sources of noise. Local sample potentials are measured by a software feedback loop which adjusts the corresponding tip voltage such that no current flows to the sample. The resulting tip voltage is then equivalent to the sample potential at the tip position. We implement this measurement method into a multi-tip scanning tunneling microscope setup such that potentials can also be measured in tunneling contact, allowing in principle truly non-invasive four-probe measurements. The resulting measurement capabilities are demonstrated for \

  16. Considerations for sampling nuclear materials for SNM accounting measurements. Special nuclear material accountability report

    International Nuclear Information System (INIS)

    Brouns, R.J.; Roberts, F.P.; Upson, U.L.

    1978-05-01

    This report presents principles and guidelines for sampling nuclear materials to measure chemical and isotopic content of the material. Development of sampling plans and procedures that maintain the random and systematic errors of sampling within acceptable limits for SNM(Special Nuclear Materials) accounting purposes are emphasized

  17. Stability of mercury concentration measurements in archived soil and peat samples

    Science.gov (United States)

    Navrátil, Tomáš; Burns, Douglas; Nováková, Tereza; Kaňa, Jiří; Rohovec, Jan; Roll, Michal; Ettler, Vojtěch

    2018-01-01

    Archived soil samples can provide important information on the history of environmental contamination and by comparison with recently collected samples, temporal trends can be inferred. Little previous work has addressed whether mercury (Hg) concentrations in soil samples are stable with long-term storage under standard laboratory conditions. In this study, we have re-analyzed using cold vapor atomic adsorption spectroscopy a set of archived soil samples that ranged from relatively pristine mountainous sites to a polluted site near a non-ferrous metal smelter with a wide range of Hg concentrations (6 - 6485 µg kg-1). Samples included organic and mineral soils and peats with a carbon content that ranged from 0.2 to 47.7%. Soil samples were stored in polyethylene bags or bottles and held in laboratory rooms where temperature was not kept to a constant value. Mercury concentrations in four subsets of samples were originally measured in 2000, 2005, 2006 and 2007, and re-analyzed in 2017, i.e. after 17, 12, 11 and 10 years of storage. Statistical analyses of either separated or lumped data yielded no significant differences between the original and current Hg concentrations. Based on these analyses, we show that archived soil and peat samples can be used to evaluate historical soil mercury contamination.

  18. Multi-Sampling Ionization Chamber (MUSIC) for measurements of fusion reactions with radioactive beams

    International Nuclear Information System (INIS)

    Carnelli, P.F.F.; Almaraz-Calderon, S.; Rehm, K.E.; Albers, M.; Alcorta, M.; Bertone, P.F.; Digiovine, B.; Esbensen, H.; Fernández Niello, J.; Henderson, D.; Jiang, C.L.; Lai, J.; Marley, S.T.; Nusair, O.; Palchan-Hazan, T.; Pardo, R.C.; Paul, M.; Ugalde, C.

    2015-01-01

    A detection technique for high-efficiency measurements of fusion reactions with low-intensity radioactive beams was developed. The technique is based on a Multi-Sampling Ionization Chamber (MUSIC) operating as an active target and detection system, where the ionization gas acts as both target and counting gas. In this way, we can sample an excitation function in an energy range determined by the gas pressure, without changing the beam energy. The detector provides internal normalization to the incident beam and drastically reduces the measuring time. In a first experiment we tested the performance of the technique by measuring the 10,13,15 C+ 12 C fusion reactions at energies around the Coulomb barrier

  19. Multi-Sampling Ionization Chamber (MUSIC) for measurements of fusion reactions with radioactive beams

    Energy Technology Data Exchange (ETDEWEB)

    Carnelli, P.F.F. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Laboratorio TANDAR, Comisión Nacional de Energía Atómica, Av. Gral. Paz 1499, B1650KNA, San Martín, Buenos Aires (Argentina); Consejo Nacional de Investigaciones Científicas y Técnicas, Av. Rivadavia 1917, C1033AAJ Buenos Aires (Argentina); Almaraz-Calderon, S. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Rehm, K.E., E-mail: rehm@anl.gov [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Albers, M.; Alcorta, M.; Bertone, P.F.; Digiovine, B.; Esbensen, H. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Fernández Niello, J. [Laboratorio TANDAR, Comisión Nacional de Energía Atómica, Av. Gral. Paz 1499, B1650KNA, San Martín, Buenos Aires (Argentina); Universidad Nacional de San Martín, Campus Miguelete, B1650BWA San Martín, Buenos Aires (Argentina); Henderson, D.; Jiang, C.L. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Lai, J. [Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA 70803 (United States); Marley, S.T.; Nusair, O.; Palchan-Hazan, T.; Pardo, R.C. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Paul, M. [Racah Institute of Physics, Hebrew University, Jerusalem (Israel); Ugalde, C. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2015-11-01

    A detection technique for high-efficiency measurements of fusion reactions with low-intensity radioactive beams was developed. The technique is based on a Multi-Sampling Ionization Chamber (MUSIC) operating as an active target and detection system, where the ionization gas acts as both target and counting gas. In this way, we can sample an excitation function in an energy range determined by the gas pressure, without changing the beam energy. The detector provides internal normalization to the incident beam and drastically reduces the measuring time. In a first experiment we tested the performance of the technique by measuring the {sup 10,13,15}C+{sup 12}C fusion reactions at energies around the Coulomb barrier.

  20. Online Oxide Contamination Measurement and Purification Demonstration

    Science.gov (United States)

    Bradley, D. E.; Godfroy, T. J.; Webster, K. L.; Garber, A. E.; Polzin, K. A.; Childers, D. J.

    2011-01-01

    Liquid metal sodium-potassium (NaK) has advantageous thermodynamic properties indicating its use as a fission reactor coolant for a surface (lunar, martian) power system. A major area of concern for fission reactor cooling systems is system corrosion due to oxygen contaminants at the high operating temperatures experienced. A small-scale, approximately 4-L capacity, simulated fission reactor cooling system employing NaK as a coolant was fabricated and tested with the goal of demonstrating a noninvasive oxygen detection and purification system. In order to generate prototypical conditions in the simulated cooling system, several system components were designed, fabricated, and tested. These major components were a fully-sealed, magnetically-coupled mechanical NaK pump, a graphite element heated reservoir, a plugging indicator system, and a cold trap. All system components were successfully demonstrated at a maximum system flow rate of approximately 150 cc/s at temperatures up to 550 C. Coolant purification was accomplished using a cold trap before and after plugging operations which showed a relative reduction in oxygen content.

  1. Connection of control circuits of machine for automatic measurement of radioactive samples

    International Nuclear Information System (INIS)

    Vorlicek, J.

    1984-01-01

    A windowless through-flow gas detector is used for measurement. The automatic machine is controlled by four flip-flops defining the following states: the dish replacement in the measuring space, washing, measurement, measured value print-out, and resetting. The first and second outputs of the first, second and third flip-flops are connected to six inputs of a block whose four outputs provide counter reset and stop-watch reset, washing, measurement, and print-out. Such machine control eliminates measurement errors by disabling sample measurement until air is removed from the measurement space, introduced on an unwashed dish or on several dishes passed under the detector. The elimination of this error is also guaranteed in manual operation. (M.D.)

  2. Study of Efficiency Calibrations of HPGe Detectors for Radioactivity Measurements of Environmental Samples

    International Nuclear Information System (INIS)

    Harb, S.; Salahel Din, K.; Abbady, A.

    2009-01-01

    In this paper, we describe a method of calibrating of efficiency of a HPGe gamma-ray spectrometry of bulk environmental samples (Tea, crops, water, and soil) is a significant part of the environmental radioactivity measurements. Here we will discuss the full energy peak efficiency (FEPE) of three HPGe detectors it as a consequence, it is essential that the efficiency is determined for each set-up employed. Besides to take full advantage at gamma-ray spectrometry, a set of efficiency at several energies which covers the wide the range in energy, the large the number of radionuclides whose concentration can be determined to measure the main natural gamma-ray emitters, the efficiency should be known at least from 46.54 keV ( 210 Pb) to 1836 keV ( 88 Y). Radioactive sources were prepared from two different standards, a first mixed standard QC Y 40 containing 210 Pb, 241 Am, 109 Cd, and Co 57 , and the second QC Y 48 containing 241 Am, 109 Cd, 57 Co, 139 Ce, 113 Sn, 85 Sr, 137 Cs, 88 Y, and 60 Co is necessary in order to calculate the activity of the different radionuclides contained in a sample. In this work, we will study the efficiency calibration as a function of different parameters as:- Energy of gamma ray from 46.54 keV ( 210 Pb) to 1836 keV ( 88 Y), three different detectors A, B, and C, geometry of containers (point source, marinelli beaker, and cylindrical bottle 1 L), height of standard soil samples in bottle 250 ml, and density of standard environmental samples. These standard environmental sample must be measured before added standard solution because we will use the same environmental samples in order to consider the self absorption especially and composition in the case of volume samples.

  3. 100 GHz pulse waveform measurement based on electro-optic sampling

    Science.gov (United States)

    Feng, Zhigang; Zhao, Kejia; Yang, Zhijun; Miao, Jingyuan; Chen, He

    2018-05-01

    We present an ultrafast pulse waveform measurement system based on an electro-optic sampling technique at 1560 nm and prepare LiTaO3-based electro-optic modulators with a coplanar waveguide structure. The transmission and reflection characteristics of electrical pulses on a coplanar waveguide terminated with an open circuit and a resistor are investigated by analyzing the corresponding time-domain pulse waveforms. We measure the output electrical pulse waveform of a 100 GHz photodiode and the obtained rise times of the impulse and step responses are 2.5 and 3.4 ps, respectively.

  4. New experimental procedure for measuring volume magnetostriction on powder samples

    International Nuclear Information System (INIS)

    Rivero, G.; Multigner, M.; Valdes, J.; Crespo, P.; Martinez, A.; Hernando, A.

    2005-01-01

    Conventional techniques used for volume magnetostriction measurements, as strain gauge or cantilever method, are very useful for ribbons or thin films but cannot be applied when the samples are in powder form. To overcome this problem a new experimental procedure has been developed. In this work, the experimental set-up is described, together with the results obtained in amorphous FeCuZr powders, which exhibit a strong dependence of the magnetization on the strength of the applied magnetic field. The magnetostriction measurements presented in this work point out that this dependence is related to a magnetovolume effect

  5. Recovery of autonomic nervous activity after myocardial infarction demonstrated by short-term measurements of SDNN

    DEFF Research Database (Denmark)

    Vaage-Nilsen, M; Rasmussen, Verner; Jensen, Gorm Boje

    2001-01-01

    OBJECTIVE: Heart rate variability (HRV) has been demonstrated to be a risk factor after acute myocardial infarction (AMI). In the present study serial measurement of SDNN (standard deviation of the mean of qualified NN-interval) in short intervals was used to assess HRV changes after AMI, and det......OBJECTIVE: Heart rate variability (HRV) has been demonstrated to be a risk factor after acute myocardial infarction (AMI). In the present study serial measurement of SDNN (standard deviation of the mean of qualified NN-interval) in short intervals was used to assess HRV changes after AMI......, and determine the role of these as independent risk factors compared to clinical, arrhythmic, ischemic and anamnestic variables. Measurements from a normal healthy middle-aged male population were used as reference (n = 63). METHODS: SDNN from a five-minute period during day and night-time, respectively......, was examined in 103 patients 1 week (n = 54), 1 month (n = 72) and 12-16 months (n = 54) after infarction. RESULTS: Day SDNN did not change during one-and-a-half years after AMI, and was significantly reduced compared with healthy males. Night SDNN, low after 1 week, with recovery 1 month after AMI...

  6. Utilization of neutrons in nuclear data measurements and bulk sample analysis

    International Nuclear Information System (INIS)

    Jonah, S. A.

    1995-01-01

    Experimental investigations were carried out with neutrons in the fields of neutron data measurements and bulk sample analysis based on the interactions of neutron interactions required in the investigations together with some salient features of the sources employed are enumerated. Excitation cross section curves and isomeric cross section ratio of 58 Ni(n,p) 58 Co m , g reaction over the neutron energy range of between 5 and 15 MeV were determined using the activation analysis technique in combination with high-resolution gamma spectroscopy. Characteristics of the incident neutrons produced via the D-T reaction of a neutron generator and D-D reaction of a cyclotron were determined experimentally to account for the contributing effects of background neutrons especially in the 5-13 MeV neutron energy range where existing data are scanty and rather discrepant. The measured data agree well with calculated data using nuclear models but deviate significantly from the recommended data based on existing literature data. The measured δ act and δ m /δ g data made it possible to determine the cross section curve for 58 Ni(n,p) 58 Co m reaction. Furthermore the flux density distributions of thermal and primary fast neutrons in different configurations of bulk samples consisting of water, graphite and coal together with the attenuation characteristics were determined by the activation analysis and pulse height response spectrometry techniques. From the results obtained, an experimental geometry has been proposed for on-line elemental analysis of coal and other minerals. Similarly the total hydrogen content and 0+C/H atomic ratio in household and motor oils as well as crude oil samples of different origins were measured by an improved experimental arrangement based on the thermal neutron reflection technique. A detection limit of 0.12 w % was obtained for hydrogen indicating the possible adaptation of this technique for quality control of petroleum products

  7. Conceptual Design and Demonstration of Space Scale for Measuring Mass in Microgravity Environment

    Directory of Open Access Journals (Sweden)

    Youn-Kyu Kim

    2015-12-01

    Full Text Available In this study, a new idea for developing a space scale for measuring mass in a microgravity environment was proposed by using the inertial force properties of an object to measure its mass. The space scale detected the momentum change of the specimen and reference masses by using a load-cell sensor as the force transducer based on Newton’s laws of motion. In addition, the space scale calculated the specimen mass by comparing the inertial forces of the specimen and reference masses in the same acceleration field. By using this concept, a space scale with a capacity of 3 kg based on the law of momentum conservation was implemented and demonstrated under microgravity conditions onboard International Space Station (ISS with an accuracy of ±1 g. By the performance analysis on the space scale, it was verified that an instrument with a compact size could be implemented and be quickly measured with a reasonable accuracy under microgravity conditions.

  8. Demonstration of measuring sea fog with an SNSPD-based Lidar system.

    Science.gov (United States)

    Zhu, Jiang; Chen, Yajun; Zhang, Labao; Jia, Xiaoqing; Feng, Zhijun; Wu, Ganhua; Yan, Xiachao; Zhai, Jiquan; Wu, Yang; Chen, Qi; Zhou, Xiaoying; Wang, Zhizhong; Zhang, Chi; Kang, Lin; Chen, Jian; Wu, Peiheng

    2017-11-08

    The monitor of sea fogs become more important with the rapid development of marine activities. Remote sensing through laser is an effective tool for monitoring sea fogs, but still challengeable for large distance. We demonstrated a Long-distance Lidar for sea fog with superconducting nanowire single-photon detector (SNSPD), which extended the ranging area to a 180-km diameter area. The system, which was verified by using a benchmark distance measurement of a known island, is applied to the Mie scattering weather prediction Lidar system. The fog echo signal distribution in the range of 42.3∼63.5 km and 53.2∼74.2 km was obtained by the Lidar system. Then the fog concentration and the velocity of the fog were deduced from the distribution, which is consistent with the weather prediction. The height of the sea fog is about two hundred meter while the visibility at this height is about 90 km due to the Earth's radius of curvature. Therefore, the capability of this SNSPD-based Lidar was close to the theoretical limit for sea fog measurements for extremely high signal-to-noise ratio of SNSPD.

  9. Accuracy of micro four-point probe measurements on inhomogeneous samples: A probe spacing dependence study

    DEFF Research Database (Denmark)

    Wang, Fei; Petersen, Dirch Hjorth; Østerberg, Frederik Westergaard

    2009-01-01

    In this paper, we discuss a probe spacing dependence study in order to estimate the accuracy of micro four-point probe measurements on inhomogeneous samples. Based on sensitivity calculations, both sheet resistance and Hall effect measurements are studied for samples (e.g. laser annealed samples...... the probe spacing is smaller than 1/40 of the variation wavelength, micro four-point probes can provide an accurate record of local properties with less than 1% measurement error. All the calculations agree well with previous experimental results.......) with periodic variations of sheet resistance, sheet carrier density, and carrier mobility. With a variation wavelength of ¿, probe spacings from 0.0012 to 1002 have been applied to characterize the local variations. The calculations show that the measurement error is highly dependent on the probe spacing. When...

  10. Sampling optimization for high-speed weigh-in-motion measurements using in-pavement strain-based sensors

    International Nuclear Information System (INIS)

    Zhang, Zhiming; Huang, Ying; Bridgelall, Raj; Palek, Leonard; Strommen, Robert

    2015-01-01

    Weigh-in-motion (WIM) measurement has been widely used for weight enforcement, pavement design, freight management, and intelligent transportation systems to monitor traffic in real-time. However, to use such sensors effectively, vehicles must exit the traffic stream and slow down to match their current capabilities. Hence, agencies need devices with higher vehicle passing speed capabilities to enable continuous weight measurements at mainline speeds. The current practices for data acquisition at such high speeds are fragmented. Deployment configurations and settings depend mainly on the experiences of operation engineers. To assure adequate data, most practitioners use very high frequency measurements that result in redundant samples, thereby diminishing the potential for real-time processing. The larger data memory requirements from higher sample rates also increase storage and processing costs. The field lacks a sampling design or standard to guide appropriate data acquisition of high-speed WIM measurements. This study develops the appropriate sample rate requirements as a function of the vehicle speed. Simulations and field experiments validate the methods developed. The results will serve as guidelines for future high-speed WIM measurements using in-pavement strain-based sensors. (paper)

  11. Sampling optimization for high-speed weigh-in-motion measurements using in-pavement strain-based sensors

    Science.gov (United States)

    Zhang, Zhiming; Huang, Ying; Bridgelall, Raj; Palek, Leonard; Strommen, Robert

    2015-06-01

    Weigh-in-motion (WIM) measurement has been widely used for weight enforcement, pavement design, freight management, and intelligent transportation systems to monitor traffic in real-time. However, to use such sensors effectively, vehicles must exit the traffic stream and slow down to match their current capabilities. Hence, agencies need devices with higher vehicle passing speed capabilities to enable continuous weight measurements at mainline speeds. The current practices for data acquisition at such high speeds are fragmented. Deployment configurations and settings depend mainly on the experiences of operation engineers. To assure adequate data, most practitioners use very high frequency measurements that result in redundant samples, thereby diminishing the potential for real-time processing. The larger data memory requirements from higher sample rates also increase storage and processing costs. The field lacks a sampling design or standard to guide appropriate data acquisition of high-speed WIM measurements. This study develops the appropriate sample rate requirements as a function of the vehicle speed. Simulations and field experiments validate the methods developed. The results will serve as guidelines for future high-speed WIM measurements using in-pavement strain-based sensors.

  12. Method for measuring the disintegration rate of a beta-emitting radionuclide in a liquid sample

    International Nuclear Information System (INIS)

    1977-01-01

    A method of measuring the distintegration rate of a beta-emitting radionuclide in a liquid sample by counting at least two differently quenched versions of the sample. In each counting operation the sample is counted in the presence of and in the absence of a standard radioactive source. A pulse height (PH) corresponding to a unique point on the pulse height spectrum generated in the presence of the standard is determined. A zero threshold sample count rate (CPM) is derived by counting the sample once in a counting window having a zero threshold lower limit. Normalized values of the measured pulse heights (PH) are developed and correlated with the corresponding counts (CPM) to determine the pulse count for a normalized pulse height value of zero and hence the sample disintegration rate

  13. Simple and rapid measurement of α-rays on smear samples using air luminescence

    International Nuclear Information System (INIS)

    Takiue, M.

    1980-01-01

    The α-activity collected on smear samples has been measured indirectly using an air luminescence counting method and a liquid scintillation spectrometer. In this method, air luminescence, attributed to the fluorescence emitted by nitrogen molecules excited by α-rays in air, serves to detect α-rays. Thus, sample preparation and α-ray measurement are simple and rapid, and moreover, no radioactive waste solution is produced. Taking into account a low background and a counting efficiency between 10 and 20%, it is estimated that the detectable limit for α-ray measurement is about 1 x 10 -7 μCi/cm 2 for loose contamination. This method is convenient to use in the routine analysis of α-ray-emitting nuclides on smear paper. (author)

  14. Trajectory Options for a Potential Mars Mission Combining Orbiting Science, Relay and a Sample Return Rendezvous Demonstration

    Science.gov (United States)

    Guinn, Joseph R.; Kerridge, Stuart J.; Wilson, Roby S.

    2012-01-01

    Mars sample return is a major scientific goal of the 2011 US National Research Council Decadal Survey for Planetary Science. Toward achievement of this goal, recent architecture studies have focused on several mission concept options for the 2018/2020 Mars launch opportunities. Mars orbiters play multiple roles in these architectures such as: relay, landing site identification/selection/certification, collection of on-going or new measurements to fill knowledge gaps, and in-orbit collection and transportation of samples from Mars to Earth. This paper reviews orbiter concepts that combine these roles and describes a novel family of relay orbits optimized for surface operations support. Additionally, these roles provide an intersection of objectives for long term NASA science, human exploration, technology development and international collaboration.

  15. The need for standardisation in the analysis, sampling and measurement of deposited radionuclides

    International Nuclear Information System (INIS)

    Tsaturov, Y.S.; De-Cort, M.; Dubois, G.; Izrael, Yu.A.; Stukin, E.D.; Fridman, D.F.; Tabachnyi, L.Ya.; Matveenko, I.I.; Guermenchuk, M.G.; Sitak, V.A.

    1996-01-01

    Following the Chernobyl accident in 1986, diverse sampling and measurement methods for radioactivity deposition have been applied by the various European institutes. When compiling these datasets together on the same data platform, in view of preparing the atlas on cesium contamination in Europe, data quality analysis has shown a lack of harmonisation between these various methods. Because of the necessity to dispose of compatible and representative measurements for further analysis, e.g. time series analysis, and the need for better Standardization methods in the event of a future accident with large transboundary release, several suggestions are made of how such harmonization might be achieved. Also in view of taking appropriate decisions in case of accidental releases by gaining experience in data Standardization, the variety of the sampling and measurement methods of radioactivity currently used are briefly summarized and the results intercompared. In order to improve the quality of datasets, GIS, amongst other methods, can be applied as a useful tool to highlight the lack of harmonisation between the various sampling methodologies by indicating the data uncertainty

  16. Effect of sample matrix composition on INAA sample weights, measurement precisions, limits of detection, and optimum conditions

    International Nuclear Information System (INIS)

    Guinn, V.P.; Nakazawa, L.; Leslie, J.

    1984-01-01

    The instrumental neutron activation analysis (INAA) Advance Prediction Computer Program (APCP) is extremely useful in guiding one to optimum subsequent experimental analyses of samples of all types of matrices. By taking into account the contributions to the cumulative Compton-continuum levels from all significant induced gamma-emitting radionuclides, it provides good INAA advance estimates of detectable photopeaks, measurement precisions, concentration lower limits of detection (LOD's) and optimum irradiation/decay/counting conditions - as well as of the very important maximum allowable sample size for each set of conditions calculated. The usefulness and importance of the four output parameters cited in the title are discussed using the INAA APCP outputs for NBS SRM-1632 Coal as the example

  17. Preparation of rock samples for measurement of the thermal neutron macroscopic absorption cross-section

    International Nuclear Information System (INIS)

    Czubek, J.A.; Burda, J.; Drozdowicz, K.; Igielski, A.; Kowalik, W.; Krynicka-Drozdowicz, E.; Woznicka, U.

    1986-03-01

    Preparation of rock samples for the measurement of the thermal neutron macroscopic absorption cross-section in small cylindrical two-region systems by a pulsed technique is presented. Requirements which should be fulfilled during the preparation of the samples due to physical assumptions of the method are given. A cylindrical vessel is filled with crushed rock and saturated with a medium strongly absorbing thermal neutrons. Water solutions of boric acid of well-known macroscopic absorption cross-section are used. Mass contributions of the components in the sample are specified. This is necessary for the calculation of the thermal neutron macroscopic absorption cross-section of the rock matrix. The conditions necessary for assuring the required accuracy of the measurement are given and the detailed procedure of preparation of the rock sample is described. (author)

  18. The method of radioactive tracer for measuring the amount of inorganic nanoparticles in biological samples

    Science.gov (United States)

    Buzulukov, Yu; Antsiferova, A.; Demin, V. A.; Demin, V. F.; Kashkarov, P.

    2015-11-01

    The method to measure the mass of inorganic nanoparticles in biological (or any other samples) using nanoparticles labeled with radioactive tracers is developed and applied to practice. The tracers are produced in original nanoparticles by radioactive activation of some of their atomic nuclei. The method of radioactive tracers demonstrates a sensitivity, specificity and accuracy equal or better than popular methods of optical and mass spectrometry, or electron microscopy and has some specific advantages. The method can be used for study of absorption, distribution, metabolism and excretion in living organism, as well as in ecological and fundamental research. It was used in practice to study absorption, distribution, metabolism and excretion of nanoparticles of Ag, Au, Se, ZnO, TiO2 as well as to study transportation of silver nanoparticles through the barriers of blood-brain, placenta and milk gland of rats. Brief descriptions of data obtained in experiments with application of this method included in the article. The method was certified in Russian Federation standard system GOST-R and recommended by the Russian Federation regulation authority ROSPOTREBNADZOR for measuring of toxicokinetic and organotropy parameters of nanoparticles.

  19. RELATIONSHIP BETWEEN COMPOSITION AND TOXICITY OF ENGINE EMISSION SAMPLES

    Energy Technology Data Exchange (ETDEWEB)

    (1)Mauderly, J; Seagrave, J; McDonald; J (2)Eide,I (3)Zielinska, B (4)Lawson, D

    2003-08-24

    Differences in the lung toxicity and bacterial mutagenicity of seven samples from gasoline and diesel vehicle emissions were reported previously [1]. Filter and vapor-phase semivolatile organic samples were collected from normal and high-emitter gasoline and diesel vehicles operated on chassis dynamometers on the Unified Driving Cycle, and the compositions of the samples were measured in detail. The two fractions of each sample were combined in their original mass collection ratios, and the toxicity of the seven samples was compared by measuring inflammation and tissue damage in rat lungs and mutagenicity in bacteria. There was good agreement among the toxicity response variables in ranking the samples and demonstrating a five-fold range of toxicity. The relationship between chemical composition and toxicity was analyzed by a combination of principal component analysis (PCA) and partial least squares regression (PLS, also known as projection to latent surfaces). The PCA /PLS analysis revealed the chemical constituents co-varying most strongly with toxicity and produced models predicting the relative toxicity of the samples with good accuracy. The results demonstrated the utility of the PCA/PLS approach, which is now being applied to additional samples, and it also provided a starting point for confirming the compounds that actually cause the effects.

  20. Sensitivity study of micro four-point probe measurements on small samples

    DEFF Research Database (Denmark)

    Wang, Fei; Petersen, Dirch Hjorth; Hansen, Torben Mikael

    2010-01-01

    probes than near the outer ones. The sensitive area is defined for infinite film, circular, square, and rectangular test pads, and convergent sensitivities are observed for small samples. The simulations show that the Hall sheet resistance RH in micro Hall measurements with position error suppression...

  1. Optimum measuring net for correcting mineralizing heterogeneity effect in XRF sampling

    International Nuclear Information System (INIS)

    Zhou Sichun; Zhao Youqing; Zhang Yuhuan

    2000-01-01

    The mineralizing heterogeneity effect in XRF sampling was investigated with theory of mathematical statistics. A method called 'Optimum measuring Net' has been developed. The theoretical estimation and experimental results show that the mineralizing heterogeneity effect can be cut down to the minimum with the method

  2. Planning an Availability Demonstration Test with Consideration of Confidence Level

    Directory of Open Access Journals (Sweden)

    Frank Müller

    2017-08-01

    Full Text Available The full service life of a technical product or system is usually not completed after an initial failure. With appropriate measures, the system can be returned to a functional state. Availability is an important parameter for evaluating such repairable systems: Failure and repair behaviors are required to determine this availability. These data are usually given as mean value distributions with a certain confidence level. Consequently, the availability value also needs to be expressed with a confidence level. This paper first highlights the bootstrap Monte Carlo simulation (BMCS for availability demonstration and inference with confidence intervals based on limited failure and repair data. The BMCS enables point-, steady-state and average availability to be determined with a confidence level based on the pure samples or mean value distributions in combination with the corresponding sample size of failure and repair behavior. Furthermore, the method enables individual sample sizes to be used. A sample calculation of a system with Weibull-distributed failure behavior and a sample of repair times is presented. Based on the BMCS, an extended, new procedure is introduced: the “inverse bootstrap Monte Carlo simulation” (IBMCS to be used for availability demonstration tests with consideration of confidence levels. The IBMCS provides a test plan comprising the required number of failures and repair actions that must be observed to demonstrate a certain availability value. The concept can be applied to each type of availability and can also be applied to the pure samples or distribution functions of failure and repair behavior. It does not require special types of distribution. In other words, for example, a Weibull, a lognormal or an exponential distribution can all be considered as distribution functions of failure and repair behavior. After presenting the IBMCS, a sample calculation will be carried out and the potential of the BMCS and the IBMCS

  3. Uncertainty measurement in the homogenization and sample reduction in the physical classification of rice and beans

    Directory of Open Access Journals (Sweden)

    Dieisson Pivoto

    2016-04-01

    Full Text Available ABSTRACT: The study aimed to i quantify the measurement uncertainty in the physical tests of rice and beans for a hypothetical defect, ii verify whether homogenization and sample reduction in the physical classification tests of rice and beans is effective to reduce the measurement uncertainty of the process and iii determine whether the increase in size of beans sample increases accuracy and reduces measurement uncertainty in a significant way. Hypothetical defects in rice and beans with different damage levels were simulated according to the testing methodology determined by the Normative Ruling of each product. The homogenization and sample reduction in the physical classification of rice and beans are not effective, transferring to the final test result a high measurement uncertainty. The sample size indicated by the Normative Ruling did not allow an appropriate homogenization and should be increased.

  4. Intercomparison of radionuclide measurements in marine fish flesh sample MA-B-3

    International Nuclear Information System (INIS)

    1987-08-01

    This final report presents results of the laboratory intercomparison of the activity concentration determination of 40 K, 90 Sr, 137 Cs, 210 Pb, 210 Po, 226 Ra, 228 Th, 230 Th, 232 Th, 238 U, 239 Pu, 240 Pu and 241 Am in the sample of garpike fish organized by the IAEA's Analytical Quality Control Service. The forty-three laboratories from twenty-three countries have reported results established by different analytical techniques. This sample is intended as a reference material for the measurement of 40 K and 137 Cs in marine biological samples and other similar matrices. 4 refs, 9 tabs

  5. Measurements of 222Rn and 226Ra Levels in environmental samples by using liquid scintillation counter

    International Nuclear Information System (INIS)

    Moustafa, A.S.

    2004-01-01

    The advantageous of liquid scintillation counting technique for 6 Ra determination compared with other methods are the high counting efficiency and the easier sample preparation, with no need for sample pre-concentration. In this work, liquid scintillation counting system was used to measure 222 Rn and 226 Ra levels in environmental samples. The liquid scintillation cocktail was prepared in the laboratory and was found efficient for measuring 222 Rn. Soil, sediment and TENORM samples were dried, grind, sieved and added to hydrochloric acid, in a standard scintillation vial, preloaded with the liquid scintillation cocktail. By measuring 222 Rn levels in the prepared vials, at different intervals of time after preparation, 222 Rn and 226 Ra levels were determined

  6. Analysis of non-contact and contact probe-to-sample thermal exchange for quantitative measurements of thin film and nanostructure thermal conductivity by the scanning hot probe method

    Science.gov (United States)

    Wilson, Adam A.

    The ability to measure thermal properties of thin films and nanostructured materials is an important aspect of many fields of academic study. A strategy especially well-suited for nanoscale investigations of these properties is the scanning hot probe technique, which is unique in its ability to non-destructively interrogate the thermal properties with high resolution, both laterally as well as through the thickness of the material. Strategies to quantitatively determine sample thermal conductivity depend on probe calibration. State of the art calibration strategies assume that the area of thermal exchange between probe and sample does not vary with sample thermal conductivity. However, little investigation has gone into determining whether or not that assumption is valid. This dissertation provides a rigorous study into the probe-to-sample heat transfer through the air gap at diffusive distances for a variety of values of sample thermal conductivity. It is demonstrated that the thermal exchange radius and gap/contact thermal resistance varies with sample thermal conductivity as well as tip-to-sample clearance in non-contact mode. In contact mode, it is demonstrated that higher thermal conductivity samples lead to a reduction in thermal exchange radius for Wollaston probe tips. Conversely, in non-contact mode and in contact mode for sharper probe tips where air contributes the most to probe-to-sample heat transfer, the opposite trend occurs. This may be attributed to the relatively strong solid-to-solid conduction occurring between probe and sample for the Wollaston probes. A three-dimensional finite element (3DFE) model was developed to investigate how the calibrated thermal exchange parameters vary with sample thermal conductivity when calibrating the probe via the intersection method in non-contact mode at diffusive distances. The 3DFE model was then used to explore the limits of sensitivity of the experiment for a range of simulated experimental conditions. It

  7. 3D-Laser-Scanning Technique Applied to Bulk Density Measurements of Apollo Lunar Samples

    Science.gov (United States)

    Macke, R. J.; Kent, J. J.; Kiefer, W. S.; Britt, D. T.

    2015-01-01

    In order to better interpret gravimetric data from orbiters such as GRAIL and LRO to understand the subsurface composition and structure of the lunar crust, it is import to have a reliable database of the density and porosity of lunar materials. To this end, we have been surveying these physical properties in both lunar meteorites and Apollo lunar samples. To measure porosity, both grain density and bulk density are required. For bulk density, our group has historically utilized sub-mm bead immersion techniques extensively, though several factors have made this technique problematic for our work with Apollo samples. Samples allocated for measurement are often smaller than optimal for the technique, leading to large error bars. Also, for some samples we were required to use pure alumina beads instead of our usual glass beads. The alumina beads were subject to undesirable static effects, producing unreliable results. Other investigators have tested the use of 3d laser scanners on meteorites for measuring bulk volumes. Early work, though promising, was plagued with difficulties including poor response on dark or reflective surfaces, difficulty reproducing sharp edges, and large processing time for producing shape models. Due to progress in technology, however, laser scanners have improved considerably in recent years. We tested this technique on 27 lunar samples in the Apollo collection using a scanner at NASA Johnson Space Center. We found it to be reliable and more precise than beads, with the added benefit that it involves no direct contact with the sample, enabling the study of particularly friable samples for which bead immersion is not possible

  8. Analyzing Repeated Measures Marginal Models on Sample Surveys with Resampling Methods

    Directory of Open Access Journals (Sweden)

    James D. Knoke

    2005-12-01

    Full Text Available Packaged statistical software for analyzing categorical, repeated measures marginal models on sample survey data with binary covariates does not appear to be available. Consequently, this report describes a customized SAS program which accomplishes such an analysis on survey data with jackknifed replicate weights for which the primary sampling unit information has been suppressed for respondent confidentiality. First, the program employs the Macro Language and the Output Delivery System (ODS to estimate the means and covariances of indicator variables for the response variables, taking the design into account. Then, it uses PROC CATMOD and ODS, ignoring the survey design, to obtain the design matrix and hypothesis test specifications. Finally, it enters these results into another run of CATMOD, which performs automated direct input of the survey design specifications and accomplishes the appropriate analysis. This customized SAS program can be employed, with minor editing, to analyze general categorical, repeated measures marginal models on sample surveys with replicate weights. Finally, the results of our analysis accounting for the survey design are compared to the results of two alternate analyses of the same data. This comparison confirms that such alternate analyses, which do not properly account for the design, do not produce useful results.

  9. Effects of (α,n) contaminants and sample multiplication on statistical neutron correlation measurements

    International Nuclear Information System (INIS)

    Dowdy, E.J.; Hansen, G.E.; Robba, A.A.; Pratt, J.C.

    1980-01-01

    The complete formalism for the use of statistical neutron fluctuation measurements for the nondestructive assay of fissionable materials has been developed. This formalism includes the effect of detector deadtime, neutron multiplicity, random neutron pulse contributions from (α,n) contaminants in the sample, and the sample multiplication of both fission-related and background neutrons

  10. Operating experience, measurements, and analysis of the LEU whole core demonstration at the FNR

    International Nuclear Information System (INIS)

    Weha, D.K.; Drumm, C.R.; King, J.S.; Martin, W.R.; Lee, J.C.

    1984-01-01

    The 2-MW Ford Nuclear Reactor at the University of Michigan is serving as the demonstration reactor for the MTR-type low enrichment (LEU) fuel for the Reduced Enrichment for Research and Test Reactor program. Operational experience gained through six months of LEU core operation and seven months of mixed HEU-LEU core operation is presented. Subcadmium flux measurements performed with rhodium self-powered neutron detectors and iron wire activations are compared with calculations. Measured reactivity parameters are compared for HEU and LEU cores. Finally, the benchmark calculations for several HEU, LEU, and mixed HEU-LEU FNR cores and the International Atomic Energy Agency (IAEA) benchmark problem are presented. (author)

  11. High mechanical Q-factor measurements on silicon bulk samples

    Energy Technology Data Exchange (ETDEWEB)

    Nawrodt, R; Zimmer, A; Koettig, T; Schwarz, C; Heinert, D; Hudl, M; Neubert, R; Thuerk, M; Nietzsche, S; Vodel, W; Seidel, P [Friedrich-Schiller-Universitaet, Institut fuer Festkoerperphysik, Helmholtzweg 5, D-07743 Jena (Germany); Tuennermann, A [Friedrich-Schiller-Universitaet, Institut fuer Angewandte Physik, Max-Wien-Platz 1, D-07743 Jena (Germany)], E-mail: ronny.nawrodt@uni-jena.de

    2008-07-15

    Future gravitational wave detectors will be limited by different kinds of noise. Thermal noise from the coatings and the substrate material will be a serious noise contribution within the detection band of these detectors. Cooling and the use of a high mechanical Q-factor material as a substrate material will reduce the thermal noise contribution from the substrates. Silicon is one of the most interesting materials for a third generation cryogenic detector. Due to the fact that the coefficient of thermal expansion vanishes at 18 and 125 K the thermoelastic contribution to the thermal noise will disappear. We present a systematic analysis of the mechanical Q-factor at low temperatures between 5 and 300 K on bulk silicon (100) samples which are boron doped. The thickness of the cylindrical samples is varied between 6, 12, 24, and 75mm with a constant diameter of 3 inches. For the 75mm substrate a comparison between the (100) and the (111) orientation is presented. In order to obtain the mechanical Q-factor a ring-down measurement is performed. Thus, the substrate is excited to resonant vibrations by means of an electrostatic driving plate and the subsequent ring-down is recorded using a Michelson-like interferometer. The substrate itself is suspended as a pendulum by means of a tungsten wire loop. All measurements are carried out in a special cryostat which provides a temperature stability of better than 0.1K between 5 and 300K during the experiment. The influence of the suspension on the measurements is experimentally investigated and discussed. At 5.8K a highest Q-factor of 4.5 x 10{sup 8} was achieved for the 14.9 kHz mode of a silicon (100) substrate with a diameter of 3 inches and a thickness of 12 mm.

  12. New approach of a transient ICP-MS measurement method for samples with high salinity.

    Science.gov (United States)

    Hein, Christina; Sander, Jonas Michael; Kautenburger, Ralf

    2017-03-01

    In the near future it is necessary to establish a disposal for high level nuclear waste (HLW) in deep and stable geological formations. In Germany typical host rocks are salt or claystone. Suitable clay formations exist in the south and in the north of Germany. The geochemical conditions of these clay formations show a strong difference. In the northern ionic strengths of the pore water up to 5M are observed. The determination of parameters like K d values during sorption experiments of metal ions like uranium or europium as homologues for trivalent actinides onto clay stones are very important for long term safety analysis. The measurement of the low concentrated, not sorbed analytes commonly takes place by inductively coupled plasma mass spectrometry (ICP-MS). A direct measurement of high saline samples like seawater with more than 1% total dissolved salt content is not possible. Alternatives like sample clean up, preconcentration or strong dilution have more disadvantages than advantages for example more preparation steps or additional and expensive components. With a small modification of the ICP-MS sample introduction system and a home-made reprogramming of the autosampler a transient analysing method was developed which is suitable for measuring metal ions like europium and uranium in high saline sample matrices up to 5M (NaCl). Comparisons at low ionic strength between the default and the transient measurement show the latter performs similarly well to the default measurement. Additionally no time consuming sample clean-up or expensive online dilution or matrix removal systems are necessary and the analysation shows a high sensitivity due to the data processing based on the peak area. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. The struggle with employee engagement: Measures and construct clarification using five samples.

    Science.gov (United States)

    Byrne, Zinta S; Peters, Janet M; Weston, James W

    2016-09-01

    Among scholarly researchers, the Utrecht Work Engagement Scale (UWES) is a popular scale for assessing employee or work engagement. However, challenges to the scale's validity have raised major concerns about the measurement and conceptualization of engagement as a construct. Across 4 field samples, we examined 2 measures of engagement, the UWES and the Job Engagement Scale (JES), in both factor structure and patterns of relationships with theoretically hypothesized antecedents and consequences. In a fifth field sample, we examined the construct-level relationships between engagement and related variables, while controlling for sources of measurement error (i.e., item-specific factor, scale-specific factor, random response, and transient). By examining 2 measures, each derived from different theoretical bases, we provide unique insight into the measurement and construct of engagement. Our results show that, although correlated, the JES and UWES are not interchangeable. The UWES, more so than the JES, assesses engagement with overlap from other job attitudes, requiring improvement in the measurement of engagement. We offer guidance as to when to use each measure. Furthermore, by isolating the construct versus measurement of engagement relative to burnout, commitment, stress, and psychological meaningfulness and availability, we determined (a) the engagement construct is not the same as the opposite of burnout, warranting a reevaluation of the opposite-of-burnout conceptualization of engagement; and (b) psychological meaningfulness and engagement are highly correlated and likely reciprocally related, necessitating a modification to the self-role-expression conceptualization of engagement. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  14. Specific calibration problems for gammaspectrometric measurements of low-level radioactivity in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, D [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Wershofen, H [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany)

    1997-03-01

    Gammaspectrometric measurements of low-level radioactivity in environmental samples are always done in a close source detector geometry. This geometry causes coincidence-summing effects for measurements of multi-photon emitting nuclides. The measurements of radioactivity in environmental samples are also influenced by the absorption of photons in the materials which have to be analysed. Both effects must be taken into account by correction factors with respect to an energy-specific calibration of the detector system for a given geometry and a given composition of the calibration source. The importance of these corrections is emphasized. It is the aim of the present paper to compare different experimental and theoretical methods for the determination of these correction factors published by various authors and to report about efforts to refine them. (orig.)

  15. Reproducibility of 5-HT2A receptor measurements and sample size estimations with [18F]altanserin PET using a bolus/infusion approach

    International Nuclear Information System (INIS)

    Haugboel, Steven; Pinborg, Lars H.; Arfan, Haroon M.; Froekjaer, Vibe M.; Svarer, Claus; Knudsen, Gitte M.; Madsen, Jacob; Dyrby, Tim B.

    2007-01-01

    To determine the reproducibility of measurements of brain 5-HT 2A receptors with an [ 18 F]altanserin PET bolus/infusion approach. Further, to estimate the sample size needed to detect regional differences between two groups and, finally, to evaluate how partial volume correction affects reproducibility and the required sample size. For assessment of the variability, six subjects were investigated with [ 18 F]altanserin PET twice, at an interval of less than 2 weeks. The sample size required to detect a 20% difference was estimated from [ 18 F]altanserin PET studies in 84 healthy subjects. Regions of interest were automatically delineated on co-registered MR and PET images. In cortical brain regions with a high density of 5-HT 2A receptors, the outcome parameter (binding potential, BP 1 ) showed high reproducibility, with a median difference between the two group measurements of 6% (range 5-12%), whereas in regions with a low receptor density, BP 1 reproducibility was lower, with a median difference of 17% (range 11-39%). Partial volume correction reduced the variability in the sample considerably. The sample size required to detect a 20% difference in brain regions with high receptor density is approximately 27, whereas for low receptor binding regions the required sample size is substantially higher. This study demonstrates that [ 18 F]altanserin PET with a bolus/infusion design has very low variability, particularly in larger brain regions with high 5-HT 2A receptor density. Moreover, partial volume correction considerably reduces the sample size required to detect regional changes between groups. (orig.)

  16. Sample design and gamma-ray counting strategy of neutron activation system for triton burnup measurements in KSTAR

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Jungmin [Department of Energy System Engineering, Seoul National University, Seoul (Korea, Republic of); Cheon, Mun Seong [ITER Korea, National Fusion Research Institute, Daejeon (Korea, Republic of); Chung, Kyoung-Jae, E-mail: jkjlsh1@snu.ac.kr [Department of Energy System Engineering, Seoul National University, Seoul (Korea, Republic of); Hwang, Y.S. [Department of Energy System Engineering, Seoul National University, Seoul (Korea, Republic of)

    2016-11-01

    Highlights: • Sample design for triton burnup ratio measurement is carried out. • Samples for 14.1 MeV neutron measurements are selected for KSTAR. • Si and Cu are the most suitable materials for d-t neutron measurements. • Appropriate γ-ray counting strategies for each selected sample are established. - Abstract: On the purpose of triton burnup measurements in Korea Superconducting Tokamak Advanced Research (KSTAR) deuterium plasmas, appropriate neutron activation system (NAS) samples for 14.1 MeV d-t neutron measurements have been designed and gamma-ray counting strategy is established. Neutronics calculations are performed with the MCNP5 neutron transport code for the KSTAR neutral beam heated deuterium plasma discharges. Based on those calculations and the assumed d-t neutron yield, the activities induced by d-t neutrons are estimated with the inventory code FISPACT-2007 for candidate sample materials: Si, Cu, Al, Fe, Nb, Co, Ti, and Ni. It is found that Si, Cu, Al, and Fe are suitable for the KSATR NAS in terms of the minimum detectable activity (MDA) calculated based on the standard deviation of blank measurements. Considering background gamma-rays radiated from surrounding structures activated by thermalized fusion neutrons, appropriate gamma-ray counting strategy for each selected sample is established.

  17. Multi-channel Waveform Sampling ASIC for radiation detection and measurement

    International Nuclear Information System (INIS)

    Shimazoe, K.; Takahashi, H.; Yeom, J.Y.; Furumiya, T.; Ohi, J.

    2013-01-01

    We have designed and fabricated a 16-channel Waveform Sampling ASIC for radiation detection and measurement. Waveform sampling is very important for the pulse shape analysis and discrimination, which is often used in radiation detection to discriminate different radiations such as alpha, beta and gamma rays. One channel of the fabricated ASIC consists of a charge-sensitive preamplifier, a VGA (Variable Gain Amplifier), an ADC (Analog to Digital Converter) and digital circuits. The preamplifier converts the current signal to the voltage signal, and the VGA amplifies the signal to appropriate level for the ADC. The ADC was designed to digitize the waveform with a frequency of 100 MHz and a resolution of 6bits. Digital circuits consist of a free-running ADC and a multiplexer which were designed to convert a digitized 100 MHz/6bit signal to a 200 MHz/3bit one, which is effective for the reduction of the number and for the achievement of the high integration in one chip. This chip was designed and fabricated with 0.35 μm CMOS technology by ROHM and the size of the ASIC is 4.9 mm by 4.9 mm. The design concept and some experimental results are shown in this paper. -- Highlights: ► Waveform sampling (WS) ASIC is newly developed for pulse shape discrimination. ► WS ASIC can be used for radiation measurement and discrimination. ► WS ASIC is fabricated by submicron CMOS technology for 5 mm × 5 mm area. ► WS ASIC achieves high integration and can be used in very limited space

  18. Assessing bilingual Chinese-English young children in Malaysia using language sample measures.

    Science.gov (United States)

    Ooi, Carmen C-W; Wong, Anita M-Y

    2012-12-01

    One reason why specific language impairment (SLI) is grossly under-identified in Malaysia is the absence of locally- developed norm-referenced language assessment tools for its multilingual and multicultural population. Spontaneous language samples provide quantitative information for language assessment, and useful descriptive information on child language development in complex language and cultural environments. This research consisted of two studies and investigated the use of measures obtained from English conversational samples among bilingual Chinese-English Malaysian preschoolers. The research found that the language sample measures were sensitive to developmental changes in this population and could identify SLI. The first study examined the relationship between age and mean length of utterance (MLU(w)), lexical diversity (D), and the index of productive syntax (IPSyn) among 52 typically-developing (TD) children aged between 3;4-6;9. Analyses showed a significant linear relationship between age and D (r = .450), the IPsyn (r = .441), and MLU(w) (r = .318). The second study compared the same measures obtained from 10 children with SLI, aged between 3;8-5;11, and their age-matched controls. The children with SLI had significantly shorter MLU(w) and lower IPSyn scores than the TD children. These findings suggest that utterance length and syntax production can be potential clinical markers of SLI in Chinese-English Malaysian children.

  19. Measuring Blood Glucose Concentrations in Photometric Glucometers Requiring Very Small Sample Volumes.

    Science.gov (United States)

    Demitri, Nevine; Zoubir, Abdelhak M

    2017-01-01

    Glucometers present an important self-monitoring tool for diabetes patients and, therefore, must exhibit high accuracy as well as good usability features. Based on an invasive photometric measurement principle that drastically reduces the volume of the blood sample needed from the patient, we present a framework that is capable of dealing with small blood samples, while maintaining the required accuracy. The framework consists of two major parts: 1) image segmentation; and 2) convergence detection. Step 1 is based on iterative mode-seeking methods to estimate the intensity value of the region of interest. We present several variations of these methods and give theoretical proofs of their convergence. Our approach is able to deal with changes in the number and position of clusters without any prior knowledge. Furthermore, we propose a method based on sparse approximation to decrease the computational load, while maintaining accuracy. Step 2 is achieved by employing temporal tracking and prediction, herewith decreasing the measurement time, and, thus, improving usability. Our framework is tested on several real datasets with different characteristics. We show that we are able to estimate the underlying glucose concentration from much smaller blood samples than is currently state of the art with sufficient accuracy according to the most recent ISO standards and reduce measurement time significantly compared to state-of-the-art methods.

  20. The challenging measurement of protein in complex biomass-derived samples

    DEFF Research Database (Denmark)

    Haven, M.O.; Jørgensen, H.

    2014-01-01

    and fast protein measurement on this type of samples was the ninhydrin assay. This method has also been used widely for this purpose, but with two different methods for protein hydrolysis prior to the assay - alkaline or acidic hydrolysis. In samples containing glucose or ethanol, there was significant...... that the presence of cellulose, lignin and glucose (above 50 g/kg) could significantly affect the results of the assay. Comparison of analyses performed with the ninhydrin assay and with a CN analyser revealed that there was good agreement between these two analytical methods, but care has to be taken when applying...... the ninhydrin assay. If used correctly, the ninhydrin assay can be used as a fast method to evaluate the adsorption of cellulases to lignin....

  1. Single- versus multiple-sample method to measure glomerular filtration rate.

    Science.gov (United States)

    Delanaye, Pierre; Flamant, Martin; Dubourg, Laurence; Vidal-Petiot, Emmanuelle; Lemoine, Sandrine; Cavalier, Etienne; Schaeffner, Elke; Ebert, Natalie; Pottel, Hans

    2018-01-08

    There are many different ways to measure glomerular filtration rate (GFR) using various exogenous filtration markers, each having their own strengths and limitations. However, not only the marker, but also the methodology may vary in many ways, including the use of urinary or plasma clearance, and, in the case of plasma clearance, the number of time points used to calculate the area under the concentration-time curve, ranging from only one (Jacobsson method) to eight (or more) blood samples. We collected the results obtained from 5106 plasma clearances (iohexol or 51Cr-ethylenediaminetetraacetic acid (EDTA)) using three to four time points, allowing GFR calculation using the slope-intercept method and the Bröchner-Mortensen correction. For each time point, the Jacobsson formula was applied to obtain the single-sample GFR. We used Bland-Altman plots to determine the accuracy of the Jacobsson method at each time point. The single-sample method showed within 10% concordances with the multiple-sample method of 66.4%, 83.6%, 91.4% and 96.0% at the time points 120, 180, 240 and ≥300 min, respectively. Concordance was poorer at lower GFR levels, and this trend is in parallel with increasing age. Results were similar in males and females. Some discordance was found in the obese subjects. Single-sample GFR is highly concordant with a multiple-sample strategy, except in the low GFR range (<30 mL/min). © The Author 2018. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  2. Product-selective blot: a technique for measuring enzyme activities in large numbers of samples and in native electrophoresis gels

    International Nuclear Information System (INIS)

    Thompson, G.A.; Davies, H.M.; McDonald, N.

    1985-01-01

    A method termed product-selective blotting has been developed for screening large numbers of samples for enzyme activity. The technique is particularly well suited to detection of enzymes in native electrophoresis gels. The principle of the method was demonstrated by blotting samples from glutaminase or glutamate synthase reactions into an agarose gel embedded with ion-exchange resin under conditions favoring binding of product (glutamate) over substrates and other substances in the reaction mixture. After washes to remove these unbound substances, the product was measured using either fluorometric staining or radiometric techniques. Glutaminase activity in native electrophoresis gels was visualized by a related procedure in which substrates and products from reactions run in the electrophoresis gel were blotted directly into a resin-containing image gel. Considering the selective-binding materials available for use in the image gel, along with the possible detection systems, this method has potentially broad application

  3. Airborne radon-222 measurement by active sampling with charcoal adsorption and gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Shizuma, Kiyoshi; Wen, Xiao-qiong; Fukami, Kenji; Iwatani, Kazuo; Hamanaka, Shun-ichi

    1998-01-01

    A simple method for measuring radon concentration in air is presented. Airborne radon is adsorbed in a charcoal bed by an active air sampling. In time, the adsorbed radon comes to attain radioactive equilibrium with its short-lived progeny 214 Pb. Utilizing this fact, radon concentration is derived from γ-ray measurement of 214 Pb. This method is estimated to be capable of detecting radon concentration in air down to 0.79 Bq·m -3 . The adsorption coefficient obtained with the method is compared with what is obtainable with passive sampling. Applications of this method to indoor and outdoor radon measurements are described. (author)

  4. A sampling device for counting insect egg clusters and measuring vertical distribution of vegetation

    Science.gov (United States)

    Robert L. Talerico; Robert W., Jr. Wilson

    1978-01-01

    The use of a vertical sampling pole that delineates known volumes and position is illustrated and demonstrated for counting egg clusters of N. sertifer. The pole can also be used to estimate vertical and horizontal coverage, distribution or damage of vegetation or foliage.

  5. Perceived social environment and adolescents' well-being and adjustment: Comparing a foster care sample with a matched sample

    OpenAIRE

    Farruggia, SP; Greenberger, E; Chen, C; Heckhausen, J

    2006-01-01

    Previous research has demonstrated that former foster care youth are at risk for poor outcomes (e.g., more problem behaviors, more depression, lower self-esteem, and poor social relationships). It is not clear, however, whether these findings reflect preemancipation developmental deficits. This study used 163 preemancipation foster care youth and a matched sample of 163 comparison youth. Results showed that foster-care youth did not differ from the comparison sample on measures of well-being,...

  6. Quality control for measurement of soil samples containing 237Np and 241Am as radiotracer

    International Nuclear Information System (INIS)

    Sha Lianmao; Zhang Caihong; Song Hailong; Ren Xiaona; Han Yuhu; Zhang Aiming; Chu Taiwei

    2003-01-01

    This paper reports quality control (QC) for the measurement of soil samples containing 237 Np and 241 Am as radiotracers in migration test of transuranic nuclides. All of the QC were done independently by the QA members of analytical work. It mainly included checking 5%-10% of the total analyzed samples; preparing blank samples, blind replicate sample and spiked samples used as quality control samples to check the quality of analytical work

  7. An unattended device for high-voltage sampling and passive measurement of thoron decay products

    Energy Technology Data Exchange (ETDEWEB)

    Gierl, Stefanie; Meisenberg, Oliver, E-mail: oliver.meisenberg@helmholtz-muenchen.de; Wielunski, Marek; Tschiersch, Jochen [Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Radiation Protection, Ingolstädter Landstr. 1, 85764 Neuherberg (Germany); Haninger, Thomas [Helmholtz Zentrum München, German Research Center for Environmental Health, Auswertungsstelle für Strahlendosimeter, Otto-Hahn-Ring 6, 81739 München (Germany)

    2014-02-15

    An integrating measurement device for the concentration of airborne thoron decay products was designed and calibrated. It is suitable for unattended use over up to several months also in inhabited dwellings. The device consists of a hemispheric capacitor with a wire mesh as the outer electrode on ground potential and the sampling substrates as the inner electrode on +7.0 kV. Negatively charged and neutral thoron decay products are accelerated to and deposited on the sampling substrates. As sampling substrates, CR39 solid-state nuclear track detectors are used in order to record the alpha decay of the sampled decay products. Nuclide discrimination is achieved by covering the detectors with aluminum foil of different thickness, which are penetrated only by alpha particles with sufficient energy. Devices of this type were calibrated against working level monitors in a thoron experimental house. The sensitivity was measured as 9.2 tracks per Bq/m{sup 3} × d of thoron decay products. The devices were used over 8 weeks in several houses built of earthen material in southern Germany, where equilibrium equivalent concentrations of 1.4–9.9 Bq/m{sup 3} of thoron decay products were measured.

  8. Reactivity Measurements On Burnt And Reference Fuel Samples In LWR-PROTEUS Phase II

    International Nuclear Information System (INIS)

    Murphy, M.; Jatuff, F.; Grimm, P.; Seiler, R.; Luethi, A.; Van Geemert, R.; Brogli, R.; Chawla, R.; Meier, G.; Berger, H.-D.

    2003-01-01

    During the year 2002, the PROTEUS research reactor was used to make a series of reactivity measurements on Pressurised Water Reactor (PWR) burnt fuel samples, and on a series of specially prepared standards. These investigations have been made in two different neutron spectra. In addition, the intrinsic neutron emissions of the burnt fuel samples have been determined. (author)

  9. Measuring larval nematode contamination on cattle pastures: Comparing two herbage sampling methods.

    Science.gov (United States)

    Verschave, S H; Levecke, B; Duchateau, L; Vercruysse, J; Charlier, J

    2015-06-15

    Assessing levels of pasture larval contamination is frequently used to study the population dynamics of the free-living stages of parasitic nematodes of livestock. Direct quantification of infective larvae (L3) on herbage is the most applied method to measure pasture larval contamination. However, herbage collection remains labour intensive and there is a lack of studies addressing the variation induced by the sampling method and the required sample size. The aim of this study was (1) to compare two different sampling methods in terms of pasture larval count results and time required to sample, (2) to assess the amount of variation in larval counts at the level of sample plot, pasture and season, respectively and (3) to calculate the required sample size to assess pasture larval contamination with a predefined precision using random plots across pasture. Eight young stock pastures of different commercial dairy herds were sampled in three consecutive seasons during the grazing season (spring, summer and autumn). On each pasture, herbage samples were collected through both a double-crossed W-transect with samples taken every 10 steps (method 1) and four random located plots of 0.16 m(2) with collection of all herbage within the plot (method 2). The average (± standard deviation (SD)) pasture larval contamination using sampling methods 1 and 2 was 325 (± 479) and 305 (± 444)L3/kg dry herbage (DH), respectively. Large discrepancies in pasture larval counts of the same pasture and season were often seen between methods, but no significant difference (P = 0.38) in larval counts between methods was found. Less time was required to collect samples with method 2. This difference in collection time between methods was most pronounced for pastures with a surface area larger than 1 ha. The variation in pasture larval counts from samples generated by random plot sampling was mainly due to the repeated measurements on the same pasture in the same season (residual variance

  10. 14C SIRI samples at CNA: Measurements at 200 kV and 1000 kV

    International Nuclear Information System (INIS)

    Santos Arévalo, Francisco-Javier; Gómez Martínez, Isabel; Agulló García, Lidia

    2015-01-01

    The Sixth International Radiocarbon Intercomparison (SIRI) exercise has taken place during late 2013 and 2014. 13 samples were distributed for AMS (Accelerator Mass Spectrometry) and 5 for radiometric laboratories, including one sample exclusively for radiometric laboratories. Being the first opportunity for our laboratory to participate actively in an intercomparison exercise, we have prepared and measured the samples in the two existing AMS dedicated facilities at the Centro Nacional de Aceleradores (CNA): SARA (Spanish Accelerator for Radionuclide Analysis), a 1 MV multielemental AMS system from HVEE, and Micadas, a 200 kV radiocarbon dating system designed by ETH. Results are presented for the two systems, together with a description of both the sample preparation and measurement procedures.

  11. 14C SIRI samples at CNA: Measurements at 200 kV and 1000 kV

    Science.gov (United States)

    Santos Arévalo, Francisco-Javier; Gómez Martínez, Isabel; Agulló García, Lidia

    2015-10-01

    The Sixth International Radiocarbon Intercomparison (SIRI) exercise has taken place during late 2013 and 2014. 13 samples were distributed for AMS (Accelerator Mass Spectrometry) and 5 for radiometric laboratories, including one sample exclusively for radiometric laboratories. Being the first opportunity for our laboratory to participate actively in an intercomparison exercise, we have prepared and measured the samples in the two existing AMS dedicated facilities at the Centro Nacional de Aceleradores (CNA): SARA (Spanish Accelerator for Radionuclide Analysis), a 1 MV multielemental AMS system from HVEE, and Micadas, a 200 kV radiocarbon dating system designed by ETH. Results are presented for the two systems, together with a description of both the sample preparation and measurement procedures.

  12. 'Intelligent' approach to radioimmunoassay sample counting employing a microprocessor controlled sample counter

    International Nuclear Information System (INIS)

    Ekins, R.P.; Sufi, S.; Malan, P.G.

    1977-01-01

    The enormous impact on medical science in the last two decades of microanalytical techniques employing radioisotopic labels has, in turn, generated a large demand for automatic radioisotopic sample counters. Such instruments frequently comprise the most important item of capital equipment required in the use of radioimmunoassay and related techniques and often form a principle bottleneck in the flow of samples through a busy laboratory. It is therefore particularly imperitive that such instruments should be used 'intelligently' and in an optimal fashion to avoid both the very large capital expenditure involved in the unnecessary proliferation of instruments and the time delays arising from their sub-optimal use. The majority of the current generation of radioactive sample counters nevertheless rely on primitive control mechanisms based on a simplistic statistical theory of radioactive sample counting which preclude their efficient and rational use. The fundamental principle upon which this approach is based is that it is useless to continue counting a radioactive sample for a time longer than that required to yield a significant increase in precision of the measurement. Thus, since substantial experimental errors occur during sample preparation, these errors should be assessed and must be releted to the counting errors for that sample. It is the objective of this presentation to demonstrate that the combination of a realistic statistical assessment of radioactive sample measurement, together with the more sophisticated control mechanisms that modern microprocessor technology make possible, may often enable savings in counter usage of the order of 5-10 fold to be made. (orig.) [de

  13. Field demonstration and transition of SCAPS direct push VOC in-situ sensing technologies

    International Nuclear Information System (INIS)

    Davis, William M.

    1999-01-01

    This project demonstrated two in-situ volatile organic compound (VOC) samplers in combination with the direct sampling ion trap mass spectrometer (DSITMS). The technologies chosen were the Vadose Sparge and the Membrane Interface Probe (MIP) sensing systems. Tests at two demonstration sites showed the newer VOC technologies capable of providing in situ contaminant measurements at two to four times the rate of the previously demonstrated Hydrosparge sensor. The results of this project provide initial results supporting the utility of these new technologies to provide rapid site characterization of VOC contaminants in the subsurface

  14. Latex Rubber Gloves as a Sampling Dosimeter Using a Novel Surrogate Sampling Device.

    Science.gov (United States)

    Sankaran, Gayatri; Lopez, Terry; Ries, Steve; Ross, John; Vega, Helen; Eastmond, David A; Krieger, Robert I

    2015-01-01

    Pesticide exposure during harvesting of crops occurs primarily to the workers' hands. When harvesters wear latex rubber gloves for personal safety and hygiene harvesting reasons, gloves accumulate pesticide residues. Hence, characterization of the gloves' properties may be useful for pesticide exposure assessments. Controlled field studies were conducted using latex rubber gloves to define the factors that influence the transfer of pesticides to the glove and that would affect their use as a residue monitoring device. A novel sampling device called the Brinkman Contact Transfer Unit (BCTU) was constructed to study the glove characteristics and residue transfer and accumulation under controlled conditions on turf. The effectiveness of latex rubber gloves as sampling dosimeters was evaluated by measuring the transferable pesticide residues as a function of time. The validation of latex rubber gloves as a residue sampling dosimeter was performed by comparing pesticide transfer and dissipation from the gloves, with the turf transferable residues sampled using the validated California (CA) Roller, a standard measure of residue transfer. The observed correlation (Pearson's correlation coefficient R(2)) between the two methods was .84 for malathion and .96 for fenpropathrin, indicating that the BCTU is a useful, reliable surrogate tool for studying available residue transfer to latex rubber gloves under experimental conditions. Perhaps more importantly, these data demonstrate that latex gloves worn by workers may be useful quantifiable matrices for measuring pesticide exposure.

  15. Creatinine measurement on dry blood spot sample for chronic kidney disease screening.

    Science.gov (United States)

    Silva, Alan Castro Azevedo E; Gómez, Juan Fidel Bencomo; Lugon, Jocemir Ronaldo; Graciano, Miguel Luis

    2016-03-01

    Chronic kidney disease (CKD) screening is advisable due to its high morbidity and mortality and is usually performed by sampling blood and urine. Here we present an innovative and simpler method, by measuring creatinine on a dry blood spot on filter paper. One-hundred and six individuals at high risk for CKD were enrolled. The creatinine values obtained using both tests and the demographic data of each participant allowed us to determinate the eGFR. The adopted cutoff for CKD was an eGFR creatinine values differences (+ 0.68mg/dl to -0.55mg/dl) inside the ± 1.96 SD, without systematic differences. Measurement of creatinine on dry blood sample is an easily feasible non-invasive diagnostic test with good accuracy that may be useful to screen chronic kidney disease.

  16. Personality in general and clinical samples: Measurement invariance of the Multidimensional Personality Questionnaire.

    Science.gov (United States)

    Eigenhuis, Annemarie; Kamphuis, Jan H; Noordhof, Arjen

    2017-09-01

    A growing body of research suggests that the same general dimensions can describe normal and pathological personality, but most of the supporting evidence is exploratory. We aim to determine in a confirmatory framework the extent to which responses on the Multidimensional Personality Questionnaire (MPQ) are identical across general and clinical samples. We tested the Dutch brief form of the MPQ (MPQ-BF-NL) for measurement invariance across a general population subsample (N = 365) and a clinical sample (N = 365), using Multiple Group Confirmatory Factor Analysis (MGCFA) and Multiple Group Exploratory Structural Equation Modeling (MGESEM). As an omnibus personality test, the MPQ-BF-NL revealed strict invariance, indicating absence of bias. Unidimensional per scale tests for measurement invariance revealed that 10% of items appeared to contain bias across samples. Item bias only affected the scale interpretation of Achievement, with individuals from the clinical sample more readily admitting to put high demands on themselves than individuals from the general sample, regardless of trait level. This formal test of equivalence provides strong evidence for the common structure of normal and pathological personality and lends further support to the clinical utility of the MPQ. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  17. Determination of the detection limit and decision threshold for ionizing radiation measurements. Part 2: Fundamentals and application to counting measurements with the influence of sample treatment

    International Nuclear Information System (INIS)

    2000-01-01

    This part of ISO 11929 addresses the field of ionizing radiation measurements in which events (in particular pulses) on samples are counted after treating them (e.g. aliquotation, solution, enrichment, separation). It considers, besides the random character of radioactive decay and of pulse counting, all other influences arising from sample treatment, (e.g. weighing, enrichment, calibration or the instability of the test setup). ISO 11929 consists of the following parts, under the general title Determination of the detection limit and decision threshold for ionizing radiation measurements: Part 1: Fundamentals and application to counting measurements without the influence of sample treatment; Part 2: Fundamentals and application to counting measurements with the influence of sample treatment; Part 3: Fundamentals and application to counting measurements by high resolution gamma spectrometry, without the influence of sample treatment; Part 4: Fundamentals and application to measurements by use of linear scale analogue ratemeters, without the influence of sample treatment. This part of ISO 11929 was prepared in parallel with other International Standards prepared by WG 2 (now WG 17): ISO 11932:1996, Activity measurements of solid materials considered for recycling, re-use or disposal as non radioactive waste, and ISO 11929-1, ISO 11929-3 and ISO 11929-4 and is, consequently, complementary to these documents

  18. AVNG system demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Thron, Jonathan Louis [Los Alamos National Laboratory; Mac Arthur, Duncan W [Los Alamos National Laboratory; Kondratov, Sergey [VNIIEF; Livke, Alexander [VNIIEF; Razinkov, Sergey [VNIIEF

    2010-01-01

    An attribute measurement system (AMS) measures a number of unclassified attributes of potentially classified material. By only displaying these unclassified results as red or green lights, the AMS protects potentially classified information while still generating confidence in the measurement result. The AVNG implementation that we describe is an AMS built by RFNC - VNIIEF in Sarov, Russia. To provide additional confidence, the AVNG was designed with two modes of operation. In the secure mode, potentially classified measurements can be made with only the simple red light/green light display. In the open mode, known unclassified material can be measured with complete display of the information collected from the radiation detectors. The AVNG demonstration, which occurred in Sarov, Russia in June 2009 for a joint US/Russian audience, included exercising both modes of AVNG operation using a number of multi-kg plutonium sources. In addition to describing the demonstration, we will show photographs and/or video taken of AVNG operation.

  19. Standardizing measurement, sampling and reporting for public exposure assessments

    Energy Technology Data Exchange (ETDEWEB)

    Rochedo, Elaine R.R. [Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear, Av. Salvador Allende s/No. CEP 22780-160 Rio de Janeiro, RJ (Brazil)], E-mail: elaine@ird.gov.br

    2008-11-15

    UNSCEAR assesses worldwide public exposure from natural and man-made sources of ionizing radiation based on information submitted to UNSCEAR by United Nations Member States and from peer reviewed scientific literature. These assessments are used as a basis for radiation protection programs of international and national regulatory and research organizations. Although UNSCEAR describes its assessment methodologies, the data are based on various monitoring approaches. In order to reduce uncertainties and improve confidence in public exposure assessments, it would be necessary to harmonize the methodologies used for sampling, measuring and reporting of environmental results.

  20. Studies on the true coincidence correction in measuring filter samples by gamma spectrometry

    CERN Document Server

    Lian Qi; Chang Yong Fu; Xia Bing

    2002-01-01

    The true coincidence correction in measuring filter samples has been studied by high efficiency HPGe gamma detectors. The true coincidence correction for a specific three excited levels de-excitation case has been analyzed, and the typical analytical expressions of true coincidence correction factors have been given. According to the measured relative efficiency on the detector surface with 8 'single' energy gamma emitters and efficiency of filter samples, the peak and total efficiency surfaces are fitted. The true coincidence correction factors of sup 6 sup 0 Co and sup 1 sup 5 sup 2 Eu calculated by the efficiency surfaces agree well with experimental results

  1. Modification of a two blood sample method used for measurement of GFR with 99mTc-DTPA.

    Science.gov (United States)

    Surma, Marian J; Płachcińska, Anna; Kuśmierek, Jacek

    2018-01-01

    Measurements of GFR may be performed with a slope/intercept method (S/I), using only two blood samples taken in strictly defined time points. The aim of the study was to modify this method in order to extend time intervals suitable for blood sampling. Modification was based on a variation of a Russel et al. model parameter, selection of time intervals suitable for blood sampling and assessment of uncertainty of calculated results. Archived values of GFR measurements of 169 patients with different renal function, from 5.5 to 179 mL/min, calculated with a multiple blood sample method were used. Concentrations of a radiopharmaceutical in consecutive minutes, from 60th to 190th after injection, were calculated theoretically, using archived parameters of biexponential functions describing a decrease in 99mTc-DTPA concentration in blood plasma with time. These values, together with injected activities, were treated as measurements and used for S/I clearance calculations. Next, values of S/I clearance were compared with the multiple blood sample method in order to calculate suitable values of exponent present in a Russel's model, for every combination of two blood sampling time points. A model was considered accurately fitted to measured values when SEE ≤ 3.6 mL/min. Assessments of uncertainty of obtained results were based on law of error superposition, taking into account mean square prediction error and also errors introduced by pipetting, time measurement and stochastic radioactive decay. The accepted criteria resulted in extension of time intervals suitable for blood sampling to: between 60 and 90 minutes after injection for the first sample and between 150 and 180 minutes for the second sample. Uncertainty of results was assessed as between 4 mL/min for GFR = 5-10 mL/min and 8 mL/min for GFR = 180 mL/min. Time intervals accepted for blood sampling fully satisfy nuclear medicine staff and ensure proper determination of GFR. Uncertainty of results is entirely

  2. PANDA-A novel instrument for non-destructive sample analysis

    International Nuclear Information System (INIS)

    Turunen, Jani; Peraejaervi, Kari; Poellaenen, Roy; Toivonen, Harri

    2010-01-01

    An instrument known as PANDA (Particles And Non-Destructive Analysis) for non-destructive sample analysis has been designed and built at the Finnish Radiation and Nuclear Safety Authority (STUK). In PANDA the measurement techniques and instruments designed for the basic research are applied to the analysis of environmental samples. PANDA has two vacuum chambers, one for loading samples and the other for measurements. In the measurement chamber there are two individual measurement positions. Currently the first one hosts an HPGe gamma detector and a position-sensitive alpha detector. The second measurement position is intended for precise characterization of found particles. PANDA's data are recorded in event mode and events are timestamped. In the present article the technical design of PANDA is presented in detail. In addition, its performance using depleted uranium particles and an air filter is demonstrated.

  3. Test plan for demonstration of Rapid Transuranic Monitoring Laboratory

    International Nuclear Information System (INIS)

    McIsaac, C.V.; Sill, C.W.; Gehrke, R.J.; Killian, E.W.; Watts, K.D.

    1993-06-01

    This plan describes tests to demonstrate the capability of the Rapid Transuranic Monitoring Laboratory (RTML) to monitor airborne alpha-emitting radionuclides and analyze soil, smear, and filter samples for alpha- and gamma-emitting radionuclides under field conditions. The RTML will be tested during June 1993 at a site adjacent to the Cold Test Pit at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. Measurement systems installed in the RTML that will be demonstrated include two large-area ionization chamber alpha spectrometers, an x-ray/gamma-ray spectrometer, and four alpha continuous air monitors. Test objectives, requirements for data quality, experimental apparatus and procedures, and safety and logistics issues are described

  4. Opacity measurements of tamped NaBr samples heated by z-pinch X-rays

    International Nuclear Information System (INIS)

    Bailey, J.E.; Arnault, P.; Blenski, T.; Dejonghe, G.; Peyrusse, O.; MacFarlane, J.J.; Mancini, R.C.; Cuneo, M.E.; Nielsen, D.S.; Rochau, G.A.

    2003-01-01

    Laboratory measurements provide benchmark data for wavelength-dependent plasma opacities to assist inertial confinement fusion, astrophysics, and atomic physics research. There are several potential benefits to using z-pinch radiation for opacity measurements, including relatively large cm-scale lateral sample sizes and relatively-long 3-5 ns experiment durations. These features enhance sample uniformity. The spectrally resolved transmission through a CH-tamped NaBr foil was measured. The z-pinch produced the X-rays for both the heating source and backlight source. The (50±4) eV foil electron temperature and (3±1)x10 21 cm -3 foil electron density were determined by analysis of the Na absorption features. LTE and NLTE opacity model calculations of the n=2 to 3, 4 transitions in bromine ionized into the M-shell are in reasonably good agreement with the data

  5. Measurement of 160Tb and 161Tb in nuclear forensics samples

    International Nuclear Information System (INIS)

    Jiang, J.; Davies, A.V.; Britton, R.E.

    2017-01-01

    160 Tb and 161 Tb are important radionuclides to measure when analysing a Nuclear Forensics sample. An analytical method for the measurement of both 160 Tb and 161 Tb was developed in this study. Terbium was separated and purified using exchange resin and TrisKem LN Resin. The purified fraction containing 160 Tb and 161 Tb was measured by gamma spectrometry and liquid scintillation counting. The counting efficiencies of 160 Tb and 161 Tb were determined using the CIEMAT/NIST efficiency tracing method. The LSC count rate ratio, R160 Tb /R161 Tb , on the reference date was determined by sequential counting and calculated using a custom script based on their half-lives. (author)

  6. Preparing and measuring ultra-small radiocarbon samples with the ARTEMIS AMS facility in Saclay, France

    Energy Technology Data Exchange (ETDEWEB)

    Delque-Kolic, E., E-mail: emmanuelle.delque-kolic@cea.fr [LMC14, CEA Saclay, Batiment 450 Porte 4E, 91191 Gif sur Yvette (France); Comby-Zerbino, C.; Ferkane, S.; Moreau, C.; Dumoulin, J.P.; Caffy, I.; Souprayen, C.; Quiles, A.; Bavay, D.; Hain, S.; Setti, V. [LMC14, CEA Saclay, Batiment 450 Porte 4E, 91191 Gif sur Yvette (France)

    2013-01-15

    The ARTEMIS facility in Saclay France measures, on average, 4500 samples a year for French organizations working in an array of fields, including environmental sciences, archeology and hydrology. In response to an increasing demand for the isolation of specific soil compounds and organic water fractions, we were motivated to evaluate our ability to reduce microgram samples using our standard graphitization lines and to measure the graphite thus obtained with our 3MV NEC Pelletron AMS. Our reduction facility consists of two fully automated graphitization lines. Each line has 12 reduction reactors with a reduction volume of 18 ml for the first line and 12 ml for the second. Under routine conditions, we determined that we could reduce the samples down to 10 {mu}g of carbon, even if the graphitization yield is consequently affected by the lower sample mass. Our results when testing different Fe/C ratios suggest that an amount of 1.5 mg of Fe powder was ideal (instead of lower amounts of catalyst) to prevent the sample from deteriorating too quickly under the Cs+ beam, and to facilitate pressing procedures. Several sets of microsamples produced from HOxI standard, international references and backgrounds were measured. When measuring {sup 14}C-free wood charcoal and HOxI samples we determined that our modern and dead blanks, due to the various preparation steps, were of 1.1 {+-} 0.8 and 0.2 {+-} 0.1 {mu}g, respectively. The results presented here were obtained for IAEA-C1, {sup 14}C-free wood, IAEA-C6, IAEA-C2 and FIRI C.

  7. Preparing and measuring ultra-small radiocarbon samples with the ARTEMIS AMS facility in Saclay, France

    International Nuclear Information System (INIS)

    Delqué-Količ, E.; Comby-Zerbino, C.; Ferkane, S.; Moreau, C.; Dumoulin, J.P.; Caffy, I.; Souprayen, C.; Quilès, A.; Bavay, D.; Hain, S.; Setti, V.

    2013-01-01

    The ARTEMIS facility in Saclay France measures, on average, 4500 samples a year for French organizations working in an array of fields, including environmental sciences, archeology and hydrology. In response to an increasing demand for the isolation of specific soil compounds and organic water fractions, we were motivated to evaluate our ability to reduce microgram samples using our standard graphitization lines and to measure the graphite thus obtained with our 3MV NEC Pelletron AMS. Our reduction facility consists of two fully automated graphitization lines. Each line has 12 reduction reactors with a reduction volume of 18 ml for the first line and 12 ml for the second. Under routine conditions, we determined that we could reduce the samples down to 10 μg of carbon, even if the graphitization yield is consequently affected by the lower sample mass. Our results when testing different Fe/C ratios suggest that an amount of 1.5 mg of Fe powder was ideal (instead of lower amounts of catalyst) to prevent the sample from deteriorating too quickly under the Cs+ beam, and to facilitate pressing procedures. Several sets of microsamples produced from HOxI standard, international references and backgrounds were measured. When measuring 14 C-free wood charcoal and HOxI samples we determined that our modern and dead blanks, due to the various preparation steps, were of 1.1 ± 0.8 and 0.2 ± 0.1 μg, respectively. The results presented here were obtained for IAEA-C1, 14 C-free wood, IAEA-C6, IAEA-C2 and FIRI C.

  8. Permeability measurements on rock samples from Unzen Scientific Drilling Project Drill Hole 4 (USDP-4)

    Science.gov (United States)

    Watanabe, Tohru; Shimizu, Yuhta; Noguchi, Satoshi; Nakada, Setsuya

    2008-07-01

    Permeability measurement was made on five rock samples from USDP-4 cores. Rock samples were collected from the conduit zone and its country rock. One sample (C14-1-1) is considered as a part of the feeder dyke for the 1991-1995 eruption. The transient pulse method was employed under confining pressure up to 50 MPa. Compressional wave velocity was measured along with permeability. The measured permeability ranges from 10 - 19 to 10 - 17 m 2 at the atmospheric pressure, and is as low as that reported for tight rocks such as granite. The permeability decreases with increasing confining pressure, while the compressional wave velocity increases. Assuming that pores are parallel elliptical tubes, the pressure dependence of permeability requires aspect ratio of 10 - 4 -10 - 2 at the atmospheric pressure. The pore aperture is estimated to be less than 1 μm. The estimated aspect ratio and pore aperture suggest that connectivity of pores is maintained by narrow cracks. The existence of cracks is supported by the pressure dependence of compressional wave velocity. Narrow cracks (< 1 μm) are observed in dyke samples, and they must have been created after solidification. Dyke samples do not provide us information of pore structures during degassing, since exsolved gas has mostly escaped and pores governing the gas permeable flow should have been lost. Both dyke and country rock samples provide us information of materials around ascending magma. Although the measured small-scale permeability cannot be directly applied to geological-scale processes, it gives constrains on studies of large-scale permeability.

  9. Comparison of fine particle measurements from a direct-reading instrument and a gravimetric sampling method.

    Science.gov (United States)

    Kim, Jee Young; Magari, Shannon R; Herrick, Robert F; Smith, Thomas J; Christiani, David C

    2004-11-01

    Particulate air pollution, specifically the fine particle fraction (PM2.5), has been associated with increased cardiopulmonary morbidity and mortality in general population studies. Occupational exposure to fine particulate matter can exceed ambient levels by a large factor. Due to increased interest in the health effects of particulate matter, many particle sampling methods have been developed In this study, two such measurement methods were used simultaneously and compared. PM2.5 was sampled using a filter-based gravimetric sampling method and a direct-reading instrument, the TSI Inc. model 8520 DUSTTRAK aerosol monitor. Both sampling methods were used to determine the PM2.5 exposure in a group of boilermakers exposed to welding fumes and residual fuel oil ash. The geometric mean PM2.5 concentration was 0.30 mg/m3 (GSD 3.25) and 0.31 mg/m3 (GSD 2.90)from the DUSTTRAK and gravimetric method, respectively. The Spearman rank correlation coefficient for the gravimetric and DUSTTRAK PM2.5 concentrations was 0.68. Linear regression models indicated that log, DUSTTRAK PM2.5 concentrations significantly predicted loge gravimetric PM2.5 concentrations (p gravimetric PM2.5 concentrations was found to be modified by surrogate measures for seasonal variation and type of aerosol. PM2.5 measurements from the DUSTTRAK are well correlated and highly predictive of measurements from the gravimetric sampling method for the aerosols in these work environments. However, results from this study suggest that aerosol particle characteristics may affect the relationship between the gravimetric and DUSTTRAK PM2.5 measurements. Recalibration of the DUSTTRAK for the specific aerosol, as recommended by the manufacturer, may be necessary to produce valid measures of airborne particulate matter.

  10. Removal of impurities from environmental water samples for tritium measurement by means of liquid scintillation counter

    International Nuclear Information System (INIS)

    Sakuma, Yoichi; Noda, Mitsuyasu

    2000-01-01

    Tritium concentration in environmental water samples is usually measured by means of liquid scintillation counting. Before the counting distillation operation is necessarily required to remove impurities, which have possibility of bad influence on the measurement, from the samples. But the operation usually takes long time and it is also troublesome. If you could simplify the purification process, you would be much easily able to measure it. Then, we have studied the probability of replacement the process by filtration aiming to simplify the procedure. We prepared several environmental water samples and also several water samples added quenching materials. These samples were purified by means of the distillation and the filtration and the impurities in them were examined. The purified samples were mixed with scintillation cocktail and the tritium concentration was measured. We added small amount of tritium in the same samples and investigated their scintillation spectra and their ESCR values in order to compare the two purification methods. Two kinds of filters were used for the filtration: 0.45 μm and 0.1 μm pore sized membrane filters. The liquid scintillation counter was LB-3 produced by Aloka Co. and Ltd. The scintillation cocktail was Ultima Gold LLT made by Packard Instrument Co and Ltd. The vial was Polyvial 145 LSD made by Zinsser Analytic Co. and Ltd. As the result, there was no significant difference between the two purification methods then the filtration method is feasible instead of the distillation. (author)

  11. On Practical Sampling of Bidirectional Reflectance

    DEFF Research Database (Denmark)

    Nielsen, Jannik Boll

    for reconstructing full and accurate BRDFs from only a few measurements is presented. It is here demonstrated that with as little as 20 point-samples, a BRDF can accurately be reconstructed. Furthermore utilising the field of view of a camera, this may be reduced to as little as two images. With this, the thesis...

  12. Receiver calibration and the nonlinearity parameter measurement of thick solid samples with diffraction and attenuation corrections.

    Science.gov (United States)

    Jeong, Hyunjo; Barnard, Daniel; Cho, Sungjong; Zhang, Shuzeng; Li, Xiongbing

    2017-11-01

    This paper presents analytical and experimental techniques for accurate determination of the nonlinearity parameter (β) in thick solid samples. When piezoelectric transducers are used for β measurements, the receiver calibration is required to determine the transfer function from which the absolute displacement can be calculated. The measured fundamental and second harmonic displacement amplitudes should be modified to account for beam diffraction and material absorption. All these issues are addressed in this study and the proposed technique is validated through the β measurements of thick solid samples. A simplified self-reciprocity calibration procedure for a broadband receiver is described. The diffraction and attenuation corrections for the fundamental and second harmonics are explicitly derived. Aluminum alloy samples in five different thicknesses (4, 6, 8, 10, 12cm) are prepared and β measurements are made using the finite amplitude, through-transmission method. The effects of diffraction and attenuation corrections on β measurements are systematically investigated. When diffraction and attenuation corrections are all properly made, the variation of β between different thickness samples is found to be less than 3.2%. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Calibration of track detectors and measurement of radon exhalation rate from solid samples

    International Nuclear Information System (INIS)

    Singh, Ajay Kumar; Jojo, P.J.; Prasad, Rajendra; Khan, A.J.; Ramachandran, T.V.

    1997-01-01

    CR-39 and LR-115 type II track detectors to be used for radon exhalation measurements have been calibrated. The configurations fitted with detectors in Can technique in the open cup mode are cylindrical plastic cup (PC) and conical plastic cup (CPC). The experiment was performed in radon exposure chamber having monodisperse aerosols of 0.2 μm size, to find the relationship between track density and the radon concentration. The calibration factors for PC and CPC type dosimeters with LR-115 type II detector were found to be 0.056 and 0.083 tracks cm -2 d -1 (Bqm -3 ) -1 respectively, while with CR-39 detector the values were 0.149 and 0.150 tracks cm -2 d -1 (Bq m -3 ) -1 . Employing the Can technique, measurements of exhalation rates from solid samples used as construction materials, are undertaken. Radon exhalation rate is found to be minimum in cement samples while in fly ash it is not enhanced as compared to coal samples. (author)

  14. X RF measurement for sediment sample collected from the niles in Khartoum State

    International Nuclear Information System (INIS)

    Mohammed, Aisha Abdelgader Ahmed

    2015-04-01

    The goal of this study to determine the concentration of element (K, Ca Ti, Mn, Fe, Cu, Zn, Pb, Rb, Sr, Y and Zr) in sediment sample collected from thirty different sites from the three rivers in Khartoum state. X-ray fluorescence (X RF) was used to identify the element concentration. Validation of the equipment was done by measuring reference samples provided by IAEA. Iron was found to be the dominant element with concentration ranged between (13000 ppm) in the white nile to (101000 ppm) in the blue nile, Pb was found to be the lowest among the twelve elements measured with concentration ranged between (11.7 ppm) in the white nile to (28 ppm) in the river nile for all samples. In general there was no variation of the concentration of elements between the blue nile sediments and the river nile sediments and was found variation of concentration of elements between the white nile sediments and other two niles. (Author).

  15. PROBES, POPULATIONS, SAMPLES, MEASUREMENTS AND RELATIONS IN STEREOLOGY

    Directory of Open Access Journals (Sweden)

    Robert T Dehoff

    2011-05-01

    Full Text Available This summary paper provides an overview of the content of stereology. The typical problem at hand centers around some three dimensional object that has an internal structure that determines its function, performance, or response. To understand and quantify the geometry of that structure it is necessary to probe it with geometric entities: points, lines, planes volumes, etc. Meaningful results are obtained only if the set of probes chosen for use in the assessment is drawn uniformly from the population of such probes for the structure as a whole. This requires an understanding of the population of each kind of probe. Interaction of the probes with the structure produce geometric events which are the focus of stereological measurements. In almost all applications the measurement that is made is a simple count of the number of these events. Rigorous application of these requirements for sample design produce unbiased estimates of geometric properties of features in the structure no matter how complex are the features or what their arrangement in space. It is this assumption-free characteristic of the methodology that makes it a powerful tool for characterizing the internal structure of three dimensional objects.

  16. Cross-cultural measurement invariance of the General Health Questionnaire-12 in a German and a Colombian population sample.

    Science.gov (United States)

    Romppel, Matthias; Hinz, Andreas; Finck, Carolyn; Young, Jeremy; Brähler, Elmar; Glaesmer, Heide

    2017-12-01

    While the General Health Questionnaire, 12-item version (GHQ-12) has been widely used in cross-cultural comparisons, rigorous tests of the measurement equivalence of different language versions are still lacking. Thus, our study aims at investigating configural, metric and scalar invariance across the German and the Spanish version of the GHQ-12 in two population samples. The GHQ-12 was applied in two large-scale population-based samples in Germany (N = 1,977) and Colombia (N = 1,500). To investigate measurement equivalence, confirmatory factor analyses were conducted in both samples. In the German sample mean GHQ-12 total scores were higher than in the Colombian sample. A one-factor model including response bias on the negatively worded items showed superior fit in the German and the Colombian sample; thus both versions of the GHQ-12 showed configural invariance. Factor loadings and intercepts were not equal across both samples; thus GHQ-12 showed no metric and scalar invariance. As both versions of the GHQ-12 did not show measurement equivalence, it is not recommendable to compare both measures and to conclude that mental distress is higher in the German sample, although we do not know if the differences are attributable to measurement problems or represent a real difference in mental distress. The study underlines the importance of measurement equivalence in cross-cultural comparisons. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Dual Si and O Isotope Measurement of Lunar Samples Using IRMS

    Science.gov (United States)

    Banerjee, N.; Hill, P. J. A.; Osinski, G. R.

    2016-12-01

    The use of isotopic systems and their associated theoretical models have become an increasingly sophisticated tool for investigating the origin of planetary bodies in the solar system. It was originally hypothesized that evidence for the impact origin of Moon would manifest itself as an isotopic heterogeneity between lunar and terrestrial samples; however, most isotope systems show no difference between the bulk Earth and Moon. The stable isotopes of both silicon (Si) and oxygen (O) have been essential in further understanding planetary processes including core formation. Historically the analysis of the Si and O isotope ratios in terrestrial and extraterrestrial material has primarily been measured independent of each other through three main techniques: isotope ratio mass spectrometry (IRMS), secondary ion mass spectrometry (SIMS), and multi-collector inductively coupled plasma mass-spectrometry (MC-ICPMS). Each technique has its own strength and weakness in regards to resolution and precision; however, one of the main limiting factors in all three of these techniques rests on the requirement of multiple aliquots. As most literature focuses on the measurement of oxygen or silicon isotopes, this unique line allows for the precise analysis of Si and O isotopes from the same aliquot of bulk sample, which cannot be done with SIMS or ICP-MS analysis. To deal with this problem a unique laser line system has been developed in the Laboratory for Stable Isotope Science at Western University, Canada, that simultaneously extracts SiF4 and O2 from the same 1-2 mg aliquot. We present the application of analyzing both isotopic systems from the sample aliquot to Apollo, meteoritic, and terrestrial samples and its implication for the formation of the Moon. Preliminary results from this line suggest that although the O isotopes ratios are consistent with a homogenous Moon-Earth system, a difference is observed in Si isotopes between Apollo and terrestrial samples compared to

  18. Implementation of an Enhanced Measurement Control Program for handling nuclear safety samples at WSRC

    International Nuclear Information System (INIS)

    Boler-Melton, C.; Holland, M.K.

    1991-01-01

    In the separation and purification of nuclear material, nuclear criticality safety (NCS) is of primary concern. The primary nuclear criticality safety controls utilized by the Savannah River Site (SRS) Separations Facilities involve administrative and process equipment controls. Additional assurance of NCS is obtained by identifying key process hold points where sampling is used to independently verify the effectiveness of production control. Nuclear safety measurements of samples from these key process locations provide a high degree of assurance that processing conditions are within administrative and procedural nuclear safety controls. An enhanced procedure management system aimed at making improvements in the quality, safety, and conduct of operation was implemented for Nuclear Safety Sample (NSS) receipt, analysis, and reporting. All procedures with nuclear safety implications were reviewed for accuracy and adequate detail to perform the analytical measurements safely, efficiently, and with the utmost quality. Laboratory personnel worked in a ''Deliberate Operating'' mode (a systematic process requiring continuous expert oversight during all phases of training, testing, and implementation) to initiate the upgrades. Thus, the effort to revise and review nuclear safety sample procedures involved a team comprised of a supervisor, chemist, and two technicians for each procedure. Each NSS procedure was upgraded to a ''Use Every Time'' (UET) procedure with sign-off steps to ensure compliance with each step for every nuclear safety sample analyzed. The upgrade program met and exceeded both the long and short term customer needs by improving measurement reliability, providing objective evidence of rigid adherence to program principles and requirements, and enhancing the system for independent verification of representative sampling from designated NCS points

  19. Acoustically levitated droplets: a contactless sampling method for fluorescence studies.

    Science.gov (United States)

    Leiterer, Jork; Grabolle, Markus; Rurack, Knut; Resch-Genger, Ute; Ziegler, Jan; Nann, Thomas; Panne, Ulrich

    2008-01-01

    Acoustic levitation is used as a new tool to study concentration-dependent processes in fluorescence spectroscopy. With this technique, small amounts of liquid and solid samples can be measured without the need for sample supports or containers, which often limits signal acquisition and can even alter sample properties due to interactions with the support material. We demonstrate that, because of the small sample volume, fluorescence measurements at high concentrations of an organic dye are possible without the limitation of inner-filter effects, which hamper such experiments in conventional, cuvette-based measurements. Furthermore, we show that acoustic levitation of liquid samples provides an experimentally simple way to study distance-dependent fluorescence modulations in semiconductor nanocrystals. The evaporation of the solvent during levitation leads to a continuous increase of solute concentration and can easily be monitored by laser-induced fluorescence.

  20. Generalized procedures for determining inspection sample sizes (related to quantitative measurements). Vol. 1: Detailed explanations

    International Nuclear Information System (INIS)

    Jaech, J.L.; Lemaire, R.J.

    1986-11-01

    Generalized procedures have been developed to determine sample sizes in connection with the planning of inspection activities. These procedures are based on different measurement methods. They are applied mainly to Bulk Handling Facilities and Physical Inventory Verifications. The present report attempts (i) to assign to appropriate statistical testers (viz. testers for gross, partial and small defects) the measurement methods to be used, and (ii) to associate the measurement uncertainties with the sample sizes required for verification. Working papers are also provided to assist in the application of the procedures. This volume contains the detailed explanations concerning the above mentioned procedures

  1. Radioactivity measurements of soil samples in the Region Vranje (Bratoselce Village) for the period 2001-2004

    International Nuclear Information System (INIS)

    Eremic-savkovic, M.; Pantelic, G.; Tanaskovic, I.; Vuletic, V.; Javorina, L.

    2006-01-01

    Systematic examination of radioactive contamination of soil samples was established at the Institute for Occupational and Radiological Health. With the bombing of our country (Spring 1999) the monitoring of radioactivity has changed. We also measured the activities of uranium and it descendants. This paper presents the results of radioactivity monitoring of the soil in small area 700 m near village Bratoselce in region Vranje during the period 2001 - 2004. From 2001 to 2004, we collected different samples from this fenced area as well as outside this area assuming not to be contaminated, before, during and after decontamination. Some soil samples were made as a mix of small samples from a large area of location. Other samples were taken at the points formerly designated as contaminated or from shell-craters seen on the fenced area surface. All samples were analyzed by gamma spectrometry and measurements of alpha and beta activity. On the basis of measurements of soil activities, analysis of 238 U and 235 U, as well as in comparison with natural activity ratio being 21.4, it may be concluded that depleted uranium contamination was present both in the fenced area and outside it, because this ratio in the samples of soil was found to be 34 to 73. Natural activity in soil samples was slightly higher in relation to mean soil activity in Serbia. (authors)

  2. An 'intelligent' approach to radioimmunoassay sample counting employing a microprocessor-controlled sample counter

    International Nuclear Information System (INIS)

    Ekins, R.P.; Sufi, S.; Malan, P.G.

    1978-01-01

    The enormous impact on medical science in the last two decades of microanalytical techniques employing radioisotopic labels has, in turn, generated a large demand for automatic radioisotopic sample counters. Such instruments frequently comprise the most important item of capital equipment required in the use of radioimmunoassay and related techniques and often form a principle bottleneck in the flow of samples through a busy laboratory. It is therefore imperative that such instruments should be used 'intelligently' and in an optimal fashion to avoid both the very large capital expenditure involved in the unnecessary proliferation of instruments and the time delays arising from their sub-optimal use. Most of the current generation of radioactive sample counters nevertheless rely on primitive control mechanisms based on a simplistic statistical theory of radioactive sample counting which preclude their efficient and rational use. The fundamental principle upon which this approach is based is that it is useless to continue counting a radioactive sample for a time longer than that required to yield a significant increase in precision of the measurement. Thus, since substantial experimental errors occur during sample preparation, these errors should be assessed and must be related to the counting errors for that sample. The objective of the paper is to demonstrate that the combination of a realistic statistical assessment of radioactive sample measurement, together with the more sophisticated control mechanisms that modern microprocessor technology make possible, may often enable savings in counter usage of the order of 5- to 10-fold to be made. (author)

  3. Natural radioactivity measurement in pumice samples used raw materials in Turkey

    International Nuclear Information System (INIS)

    Turhan, S.; Yuecel, H.; Guenduez, L.; Sahin, S.; Vural, M.; Parmaksiz, A.; Demircioglu, B.

    2007-01-01

    The activity concentrations of 232 Th, 226 Ra, and 4 K in different pumice samples have been determined by high-resolution γ-ray spectrometry using a 110% HpGe detector. The radium equivalent activities (Ra eq ), external hazard index (H ex ), and internal hazard index (H in ) associated with the natural radionuclides and representative level index (I γ r ) are calculated to assess the radiation hazard of the natural radioactivity in the pumice samples. The mean values of the measured radioactivity concentrations of 232 Th, 226 Ra, and 4 K for pumice samples from the region of lakes (ROL) are 232.4±8.0, 196.9±7.8, and 1325.8±20.4 Bq kg -1 and for pumice samples from Cukurova region (CR) 16.3±4.0, 16.1±4.9, and 479.7±170.4 Bq kg -1 , respectively. The calculated Ra eq values vary from 435.9±12.5 to 883.6±41.5 Bq kg -1 with a mean of 630.9±20.2 Bq kg -1 for the ROL samples and from 49.7±3.3 to 101.9±7.2 Bq kg -1 with a mean of 76.3±23.7 Bq kg -1 for the CR samples. For the ROL samples, Ra eq are above the limit of 370 Bq kg -1 , equivalent to external γ dose of 1.5 mSv yr -1 , recommended for the safe use of construction materials by NEA-OECD, while for the CR samples, Ra eq values are lower than the limit

  4. Quantitative And Qualitative Measurement Of Radio- Activity In Sand Samples From Chalet Beach In Songkhla Province

    International Nuclear Information System (INIS)

    Sukhowattanakit, Jirapa; Kessaratikoon, Prasong; Udomsomporn, Suchin; Thorarit, Wutthidej

    2005-10-01

    The quantitative and qualitative measurement of radioactivity in 39 sand samples collected from Chalatat beach in Songkhla province are presented. Experimental results were obtained by using a high-purity germanium detector and gamma spectroscopy analysis system and comparing to the standard soil (IAEA SOIL 6) at the Office of Atoms for Peace (OAP). The measuring time of all sand samples is 10,000 seconds. Some radioisotopes such as K-40, Cs-137, Tl-208, Bi-212, Pb-212, Bi-214, Pb- 214, Ra-226 and Ac-228 were found in sand samples. In addition, the radioactivity of Ra-226 and Cs-137 in those samples were found in normal level

  5. NID Copper Sample Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kouzes, Richard T.; Zhu, Zihua

    2011-09-12

    The current focal point of the nuclear physics program at PNNL is the MAJORANA DEMONSTRATOR, and the follow-on Tonne-Scale experiment, a large array of ultra-low background high-purity germanium detectors, enriched in 76Ge, designed to search for zero-neutrino double-beta decay (0νββ). This experiment requires the use of germanium isotopically enriched in 76Ge. The MAJORANA DEMONSTRATOR is a DOE and NSF funded project with a major science impact. The DEMONSTRATOR will utilize 76Ge from Russia, but for the Tonne-Scale experiment it is hoped that an alternate technology, possibly one under development at Nonlinear Ion Dynamics (NID), will be a viable, US-based, lower-cost source of separated material. Samples of separated material from NID require analysis to determine the isotopic distribution and impurities. DOE is funding NID through an SBIR grant for development of their separation technology for application to the Tonne-Scale experiment. The Environmental Molecular Sciences facility (EMSL), a DOE user facility at PNNL, has the required mass spectroscopy instruments for making isotopic measurements that are essential to the quality assurance for the MAJORANA DEMONSTRATOR and for the development of the future separation technology required for the Tonne-Scale experiment. A sample of isotopically separated copper was provided by NID to PNNL in January 2011 for isotopic analysis as a test of the NID technology. The results of that analysis are reported here. A second sample of isotopically separated copper was provided by NID to PNNL in August 2011 for isotopic analysis as a test of the NID technology. The results of that analysis are also reported here.

  6. Manual for the Epithermal Neutron Multiplicity Detector (ENMC) for Measurement of Impure MOX and Plutonium Samples

    International Nuclear Information System (INIS)

    Menlove, H. O.; Rael, C. D.; Kroncke, K. E.; DeAguero, K. J.

    2004-01-01

    We have designed a high-efficiency neutron detector for passive neutron coincidence and multiplicity counting of dirty scrap and bulk samples of plutonium. The counter will be used for the measurement of impure plutonium samples at the JNC MOX fabrication facility in Japan. The counter can also be used to create working standards from bulk process MOX. The detector uses advanced design "3He tubes to increase the efficiency and to shorten the neutron die-away time. The efficiency is 64% and the die-away time is 19.1 ?s. The Epithermal Neutron Multiplicity Counter (ENMC) is designed for high-precision measurements of bulk plutonium samples with diameters of less than 200 mm. The average neutron energy from the sample can be measured using the ratio of the inner ring of He-3 tubes to the outer ring. This report describes the hardware, performance, and calibration for the ENMC.

  7. Ultralow-level measurement of organically-bound tritium in bioassay samples

    International Nuclear Information System (INIS)

    Kotzer, T.; Trivedi, A.; Waito, G.; Workman, W.

    1998-12-01

    An intercomparison study of urine samples having high levels (5 Bq·L -1 ) of organically-bound tritium (OBT) was conducted, in conjunction with the oxygen combustion-liquid scintillation counting (LSC) method, to evaluate the suitability and sensitivity of the 3 He-ingrowth mass spectrometry (MS) technique for OBT in bioassay samples. The study established that 3 He ingrowth-MS has the required sensitivity to measure ultralow levels of OBT-in-urine (∼0.1 Bq·L -1 ). Cumulative 24 h urine samples from a few members of the general population, living in the vicinity of the heavy-water research reactor facility at Chalk River Laboratories (CRL) at Chalk River, were collected and analyzed for tritiated water (HTO) and OBT. The participants were from Ottawa (200 km east), Deep River (10 km west) and an occasionally occupationally HTO-exposed worker at CRL. HTO-in-urine values were 6.5 Bq·L -1 for the Ottawa resident, 15.8 Bq·L -1 for the Deep River resident, and 1260 Bq·L -1 for the exposed worker. OBT-in-urine levels from these same individuals were 0.06 Bq·L -1 (Ottawa), 0.29 Bq·L -1 (Deep River), and 2.2 Bq·L -1 (exposed worker). With a model developed for calculating OBT dose fraction from the measured ratio of HTO to OBT in urine, we estimated that the dose arising from OBT in the body was about 26% of the total tritium dose for the Ottawa resident and 50% for the Deep River resident. The CRL individual had a 5% dose contribution from OBT, but had higher overall tritium dose due to frequent intakes of HTO. The study indicates that the bulk of the tritium dose to the population is the result of HTO intakes and not due to dietary intake of OBT. (author)

  8. 40 K, 137 Cs and 232 Th activities in Brazilian milk samples measured by gamma ray spectrometry

    International Nuclear Information System (INIS)

    Melquiades, Fabio L.; Appoloni, Carlos R.

    2000-01-01

    This work deals with the measurement of radioactive activities in powdered milk, with high resolution gamma-ray spectrometry, using a HPGe detector coupled to a standard electronic nuclear chain and a multichannel card of 8192 channels. Preliminary measurements were accomplished to define the kind of the system shield, the geometry of the sample recipient, the size of the sampling and the self absorption correction. It was possible to measure the radionuclides 40 K, 137 Cs and 208 Tl, whose activities were calculated according to the International Atomic Energy Agency norms. The detector efficiency was measured employing calibrated samples, prepared with IAEA certificate standards mixed with powdered milk. Tukey's average comparison test was used to check the repeatability of the measurements and the absence of significant systematic deviation. (author)

  9. Quantitative autoradiography - a method of radioactivity measurement

    International Nuclear Information System (INIS)

    Treutler, H.C.; Freyer, K.

    1988-01-01

    In the last years the autoradiography has been developed to a quantitative method of radioactivity measurement. Operating techniques of quantitative autoradiography are demonstrated using special standard objects. Influences of irradiation quality, of backscattering in sample and detector materials, and of sensitivity and fading of the detectors are considered. Furthermore, questions of quantitative evaluation of autoradiograms are dealt with, and measuring errors are discussed. Finally, some practical uses of quantitative autoradiography are demonstrated by means of the estimation of activity distribution in radioactive foil samples. (author)

  10. Stable isotope ratio measurements on highly enriched water samples by means of laser spectrometry

    NARCIS (Netherlands)

    van Trigt, R; Kerstel, E.R.T.; Visser, GH; Meijer, H.A.J.

    2001-01-01

    We demonstrate the feasibility of using laser spectrometry (LS) to analyze isotopically highly enriched water samples (i.e., delta H-2 less than or equal to 15000 parts per thousand, delta O-18 less than or equal to 1200 parts per thousand), as often used in the biomedical doubly labeled water (DLW)

  11. Responsibility as a dimension of HIV prevention normative beliefs: measurement in three drug-using samples.

    Science.gov (United States)

    Ross, M W; Timpson, S C; Williams, M L; Amos, C; McCurdy, S; Bowen, A M; Kilonzo, G P

    2007-03-01

    The concept of responsibility was derived originally from principles of morality, as part of a network of rights, duties and obligations. HIV risk-related studies have suggested that a sense of responsibility for condom use to protect a partner is a potentially important predictor of condom use in drug-using populations. We created a four-item scale measuring Self responsibility to use condoms and Partner's responsibility to use condoms. Data were collected from three drug-using samples: crack smokers, HIV seropositive crack smokers in an intervention study in Houston, Texas, and Tanzanian heroin users in Dar es Salaam. Data indicated that the four responsibility items had high alpha coefficients in each sample, and that there were moderate to high intercorrelations between equivalent self and partner responsibility items. There were significant differences in scale scores between the crack smokers and the HIV positive crack smokers and the Tanzanian samples, but no significant differences between the HIV positive and Tanzanian samples. Comparing within the first crack-smoker sample those who were HIV positive and negative showed significant differences in the direction of higher beliefs in responsibility to use condoms in the HIV positive group. These data suggest that responsibility is measurable, holds similar psychometric properties across three samples differing in culture and HIV serostatus, and that condom use responsibility is conceptualized as a measure of general responsibility rather than as a reciprocal self/partner responsibility.

  12. High spatial sampling global mode structure measurements via multichannel reflectometry in NSTX

    Energy Technology Data Exchange (ETDEWEB)

    Crocker, N A; Peebles, W A; Kubota, S; Zhang, J [Department of Physics and Astronomy, University of California-Los Angeles, Los Angeles, CA 90095-7099 (United States); Bell, R E; Fredrickson, E D; Gorelenkov, N N; LeBlanc, B P; Menard, J E; Podesta, M [Princeton Plasma Physics Laboratory, PO Box 451, Princeton, NJ 08543-0451 (United States); Sabbagh, S A [Department of Applied Physics and Applied Mathematics, Columbia University, New York, NY 10027 (United States); Tritz, K [Johns Hopkins University, Baltimore, MD 21218 (United States); Yuh, H [Nova Photonics, Princeton, NJ 08540 (United States)

    2011-10-15

    Global modes-including kinks and tearing modes (f <{approx} 50 kHz), toroidicity-induced Alfven eigenmodes (TAE; f {approx} 50-250 kHz) and global and compressional Alfven eigenmodes (GAE and CAE; f >{approx} 400 kHz)-play critical roles in many aspects of plasma performance. Their investigation on NSTX is aided by an array of fixed-frequency quadrature reflectometers used to determine their radial density perturbation structure. The array has been recently upgraded to 16 channels spanning 30-75 GHz (n{sub cutoff} = (1.1-6.9) x 10{sup 19} m{sup -3} in O-mode), improving spatial sampling and access to the core of H-mode plasmas. The upgrade has yielded significant new results that advance the understanding of global modes in NSTX. The GAE and CAE structures have been measured for the first time in the core of an NSTX high-power (6 MW) beam-heated H-mode plasma. The CAE structure is strongly core-localized, which has important implications for electron thermal transport. The TAE structure has been measured with greatly improved spatial sampling, and measurements of the TAE phase, the first in NSTX, show strong radial variation near the midplane, indicating radial propagation caused by non-ideal MHD effects. Finally, the tearing mode structure measurements provide unambiguous evidence of coupling to an external kink.

  13. Characterization of electron microscopes with binary pseudo-random multilayer test samples

    Science.gov (United States)

    Yashchuk, Valeriy V.; Conley, Raymond; Anderson, Erik H.; Barber, Samuel K.; Bouet, Nathalie; McKinney, Wayne R.; Takacs, Peter Z.; Voronov, Dmitriy L.

    2011-09-01

    Verification of the reliability of metrology data from high quality X-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays has been suggested [1,2] and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer [5]. Here we describe the details of development of binary pseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi 2/Si multilayer coating with pseudo-randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize X-ray microscopes. Corresponding work with X-ray microscopes is in progress.

  14. Characterization of electron microscopes with binary pseudo-random multilayer test samples

    International Nuclear Information System (INIS)

    Yashchuk, Valeriy V.; Conley, Raymond; Anderson, Erik H.; Barber, Samuel K.; Bouet, Nathalie; McKinney, Wayne R.; Takacs, Peter Z.; Voronov, Dmitriy L.

    2011-01-01

    Verification of the reliability of metrology data from high quality X-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays has been suggested and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer [5]. Here we describe the details of development of binary pseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi 2 /Si multilayer coating with pseudo-randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize X-ray microscopes. Corresponding work with X-ray microscopes is in progress.

  15. Gene coexpression measures in large heterogeneous samples using count statistics.

    Science.gov (United States)

    Wang, Y X Rachel; Waterman, Michael S; Huang, Haiyan

    2014-11-18

    With the advent of high-throughput technologies making large-scale gene expression data readily available, developing appropriate computational tools to process these data and distill insights into systems biology has been an important part of the "big data" challenge. Gene coexpression is one of the earliest techniques developed that is still widely in use for functional annotation, pathway analysis, and, most importantly, the reconstruction of gene regulatory networks, based on gene expression data. However, most coexpression measures do not specifically account for local features in expression profiles. For example, it is very likely that the patterns of gene association may change or only exist in a subset of the samples, especially when the samples are pooled from a range of experiments. We propose two new gene coexpression statistics based on counting local patterns of gene expression ranks to take into account the potentially diverse nature of gene interactions. In particular, one of our statistics is designed for time-course data with local dependence structures, such as time series coupled over a subregion of the time domain. We provide asymptotic analysis of their distributions and power, and evaluate their performance against a wide range of existing coexpression measures on simulated and real data. Our new statistics are fast to compute, robust against outliers, and show comparable and often better general performance.

  16. EU-project AEROJET. Non-intrusive measurements of aircraft engine exhaust emissions

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, K.; Heland, J. [Fraunhofer-Inst. fuer Atmosphaerische Umweltforschung (IFU), Garmisch-Partenkirchen (Germany); Burrows, R. [Rolls-Royce Ltd. (United Kingdom). Engine Support Lab.; Bernard, M. [AUXITROL, S.A. (France). Aerospace Equipment Div.; Bishop, G. [British Aerospace (United Kingdom). Sowerby Research Centre; Lindermeir, E. [Deutsche Forschungsanstalt fuer Luft- und Raumfahrt e. V. (DLR), Bonn (Germany). Inst. fuer Optoelektronik; Lister, D.H. [Defence and Research Agency, Hants (United Kingdom). Propulsion and Development Dept.; Wiesen, P. [Bergische Univ. Wuppertal (Gesamthochshule) (Germany); Hilton, M. [University of Reading (United Kingdom). Dept. of Physics

    1997-12-31

    The main goal of the AEROJET programme is to demonstrate the equivalence of remote measurement techniques to conventional extractive methods for both gaseous and particulate measurements. The different remote measurement techniques are compared and calibrated. A demonstrator measurement system for exhaust gases, temperature and particulates including data-analysis software is regarded as result of this project. Non-intrusive measurements are the method of choice within the AEROJET project promising to avoid the disadvantages of the gas sampling techniques which are currently used. Different ground based non-intrusive measurement methods are demonstrated during a final evaluation phase. Several non-intrusive techniques are compared with conventional gas sampling and analysis techniques. (R.P.) 3 refs.

  17. EU-project AEROJET. Non-intrusive measurements of aircraft engine exhaust emissions

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, K; Heland, J [Fraunhofer-Inst. fuer Atmosphaerische Umweltforschung (IFU), Garmisch-Partenkirchen (Germany); Burrows, R [Rolls-Royce Ltd. (United Kingdom). Engine Support Lab.; Bernard, M [AUXITROL, S.A. (France). Aerospace Equipment Div.; Bishop, G [British Aerospace (United Kingdom). Sowerby Research Centre; Lindermeir, E [Deutsche Forschungsanstalt fuer Luft- und Raumfahrt e. V. (DLR), Bonn (Germany). Inst. fuer Optoelektronik; Lister, D H [Defence and Research Agency, Hants (United Kingdom). Propulsion and Development Dept.; Wiesen, P [Bergische Univ. Wuppertal (Gesamthochshule) (Germany); Hilton, M [University of Reading (United Kingdom). Dept. of Physics

    1998-12-31

    The main goal of the AEROJET programme is to demonstrate the equivalence of remote measurement techniques to conventional extractive methods for both gaseous and particulate measurements. The different remote measurement techniques are compared and calibrated. A demonstrator measurement system for exhaust gases, temperature and particulates including data-analysis software is regarded as result of this project. Non-intrusive measurements are the method of choice within the AEROJET project promising to avoid the disadvantages of the gas sampling techniques which are currently used. Different ground based non-intrusive measurement methods are demonstrated during a final evaluation phase. Several non-intrusive techniques are compared with conventional gas sampling and analysis techniques. (R.P.) 3 refs.

  18. (n,{alpha}) cross section measurement of gaseous sample using gridded ionization chamber. Cross section determination

    Energy Technology Data Exchange (ETDEWEB)

    Sanami, Toshiya; Baba, Mamoru; Saito, Keiichiro; Ibara, Yasutaka; Hirakawa, Naohiro [Tohoku Univ., Sendai (Japan). Faculty of Engineering

    1997-03-01

    We are developing a method of (n,{alpha}) cross section measurement using gaseous samples in a gridded ionization chamber (GIC). This method enables cross section measurements in large solid angle without the distortion by the energy loss in a sample, but requires a method to estimate the detection efficiency. We solve this problem by using GIC signals and a tight neutron collimation. The validity of this method was confirmed through the {sup 12}C(n,{alpha}{sub 0}){sup 9}Be measurement. We applied this method to the {sup 16}O(n,{alpha}){sup 13}C cross section around 14.1 MeV. (author)

  19. {sup 14}C SIRI samples at CNA: Measurements at 200 kV and 1000 kV

    Energy Technology Data Exchange (ETDEWEB)

    Santos Arévalo, Francisco-Javier, E-mail: fj.santos@csic.es; Gómez Martínez, Isabel; Agulló García, Lidia

    2015-10-15

    The Sixth International Radiocarbon Intercomparison (SIRI) exercise has taken place during late 2013 and 2014. 13 samples were distributed for AMS (Accelerator Mass Spectrometry) and 5 for radiometric laboratories, including one sample exclusively for radiometric laboratories. Being the first opportunity for our laboratory to participate actively in an intercomparison exercise, we have prepared and measured the samples in the two existing AMS dedicated facilities at the Centro Nacional de Aceleradores (CNA): SARA (Spanish Accelerator for Radionuclide Analysis), a 1 MV multielemental AMS system from HVEE, and Micadas, a 200 kV radiocarbon dating system designed by ETH. Results are presented for the two systems, together with a description of both the sample preparation and measurement procedures.

  20. The Development of Low-Level Measurement Capabilities for Total and Isotopic Uranium in Environmental Samples at Brazilian and Argentine Laboratories by ABACC

    International Nuclear Information System (INIS)

    Guidicini, Olga M.; Olsen, Khris B.; Hembree, Doyle M.; Carter, Joel A.; Whitaker, Michael; Hayes, Susan M.

    2005-01-01

    In June 1998, the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC), with assistance from the U.S. Department of Energy (DOE), began a program to assess environmental sampling and analysis capabilities at laboratories in Argentina and Brazil. The program began with staff training conducted in South America and the United States by Oak Ridge National Laboratory (ORNL) and Pacific Northwest National Laboratory (PNNL). Both laboratories are participating members of DOE's Network of Analytical Laboratories (NWAL) that support IAEA's environmental sampling program. During the initial planning meeting, representatives from ABACC and all the participating analytical laboratories supporting ABACC were briefed on how the first exercise would be managed and on key aspects necessary to analyze low-level environmental samples for uranium. Subsequent to this training, a laboratory evaluation exercise (Exercise 1) was conducted using standard swipe samples prepared for this exercise by the International Atomic Energy Agency (IAEA). The results of Exercise 1 determined that sample contamination was a major factor in the analysis, and a thorough review of laboratory procedures was required to reduce the level of contamination to acceptable levels. Following modification of sample preparation procedures, the laboratories performed Exercise 2, an analysis of a National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 1547, Peach Leaves. The results of Exercise 2 demonstrated that several laboratories were capable of accurately determining the total uranium and uranium isotopic distribution in the peach leaves. To build on these successes, Exercise 3 was performed using a series of standard swipe samples prepared by the IAEA and distributed to laboratories supporting ABACC and to PNNL and ORNL. The results of Exercise 3 demonstrate that ABACC now has support laboratories in both Argentina and Brazil, which are capable of

  1. Testing of an automated online EA-IRMS method for fast and simultaneous carbon content and stable isotope measurement of aerosol samples

    Science.gov (United States)

    Major, István; Gyökös, Brigitta; Túri, Marianna; Futó, István; Filep, Ágnes; Hoffer, András; Molnár, Mihály

    2016-04-01

    Comprehensive atmospheric studies have demonstrated that carbonaceous aerosol is one of the main components of atmospheric particulate matter over Europe. Various methods, considering optical or thermal properties, have been developed for quantification of the accurate amount of both organic and elemental carbon constituents of atmospheric aerosol. The aim of our work was to develop an alternative fast and easy method for determination of the total carbon content of individual aerosol samples collected on prebaked quartz filters whereby the mass and surface concentration becomes simply computable. We applied the conventional "elemental analyzer (EA) coupled online with an isotope ratio mass spectrometer (IRMS)" technique which is ubiquitously used in mass spectrometry. Using this technique we are able to measure simultaneously the carbon stable isotope ratio of the samples, as well. During the developing process, we compared the EA-IRMS technique with an off-line catalytic combustion method worked out previously at Hertelendi Laboratory of Environmental Studies (HEKAL). We tested the combined online total carbon content and stable isotope ratio measurement both on standard materials and real aerosol samples. Regarding the test results the novel method assures, on the one hand, at least 95% of carbon recovery yield in a broad total carbon mass range (between 100 and 3000 ug) and, on the other hand, a good reproducibility of stable isotope measurements with an uncertainty of ± 0.2 per mill. Comparing the total carbon results obtained by the EA-IRMS and the off-line catalytic combustion method we found a very good correlation (R2=0.94) that proves the applicability of both preparation method. Advantages of the novel method are the fast and simplified sample preparation steps and the fully automated, simultaneous carbon stable isotope ratio measurement processes. Furthermore stable isotope ratio results can effectively be applied in the source apportionment

  2. Uniform Sampling Table Method and its Applications II--Evaluating the Uniform Sampling by Experiment.

    Science.gov (United States)

    Chen, Yibin; Chen, Jiaxi; Chen, Xuan; Wang, Min; Wang, Wei

    2015-01-01

    A new method of uniform sampling is evaluated in this paper. The items and indexes were adopted to evaluate the rationality of the uniform sampling. The evaluation items included convenience of operation, uniformity of sampling site distribution, and accuracy and precision of measured results. The evaluation indexes included operational complexity, occupation rate of sampling site in a row and column, relative accuracy of pill weight, and relative deviation of pill weight. They were obtained from three kinds of drugs with different shape and size by four kinds of sampling methods. Gray correlation analysis was adopted to make the comprehensive evaluation by comparing it with the standard method. The experimental results showed that the convenience of uniform sampling method was 1 (100%), odds ratio of occupation rate in a row and column was infinity, relative accuracy was 99.50-99.89%, reproducibility RSD was 0.45-0.89%, and weighted incidence degree exceeded the standard method. Hence, the uniform sampling method was easy to operate, and the selected samples were distributed uniformly. The experimental results demonstrated that the uniform sampling method has good accuracy and reproducibility, which can be put into use in drugs analysis.

  3. Tritium Activity Measurement of Water Samples Using Liquid Scintillation Counter and Electrolytical Enrichment

    International Nuclear Information System (INIS)

    Baresic, J.; Krajcar Bronic, I.; Horvatincic, N.; Obelic, B.; Sironic, A.; Kozar-Logar J.

    2011-01-01

    Tritium (3H) activity of natural waters (precipitation, groundwater, surface waters) has recently become too low to be directly measured by low-level liquid scintillation (LSC) techniques. It is therefore necessary to perform electrolytical enrichment of tritium in such waters prior to LSC measurements. Electrolytical enrichment procedure has been implemented at the Rudjer Boskovic Institute (RBI) Tritium Laboratory in 2008, and since then 19 electrolyses have been completed. The mean enrichment factor E (a ratio between the final and initial 3H activities) after stabilisation of the system is E R BI = 22.5 @ 0.5, and the mean enrichment parameter (which describes the process of water mass reduction during electrolysis) is P R BI 0.949 @ 0.003. These values are comparable with those obtained at the Jo@ef Stefan Institute (JSI) Laboratory for liquid scintillation counting, at the electrolysis equipment of the same producer (AGH University of Science and Technology, Krakow, Poland) after 66 electrolyses carried out under identical conditions since 2007: E J SI = 18.9 @ 1.5, and P J SI = 0.896 @ 0.021. Both RBI and JSI laboratories have Ultra-low-level LSC Quantulus 1220 (Wallac, PerkinElmer) for measurement of 3H activity. A set of water samples having 3H activities in the range from 0 TU (''dead-water'' samples) to 18 000 TU (1 TU 0.118 Bq/L) were measured at both laboratories. Samples having 3H activity <200 TU were electrolytically enriched, while the others were measured directly in LSC. A very good agreement was obtained (correlation coefficient 0.991). Both laboratories participated in the IAEA TRIC2008 international intercomparison exercise. The analyses of reported 3H activity results in terms of z and u parameters showed that all results in both laboratories were acceptable. (author)

  4. Accounting for sensor calibration, data validation, measurement and sampling uncertainties in monitoring urban drainage systems.

    Science.gov (United States)

    Bertrand-Krajewski, J L; Bardin, J P; Mourad, M; Béranger, Y

    2003-01-01

    Assessing the functioning and the performance of urban drainage systems on both rainfall event and yearly time scales is usually based on online measurements of flow rates and on samples of influent effluent for some rainfall events per year. In order to draw pertinent scientific and operational conclusions from the measurement results, it is absolutely necessary to use appropriate methods and techniques in order to i) calibrate sensors and analytical methods, ii) validate raw data, iii) evaluate measurement uncertainties, iv) evaluate the number of rainfall events to sample per year in order to determine performance indicator with a given uncertainty. Based an previous work, the paper gives a synthetic review of required and techniques, and illustrates their application to storage and settling tanks. Experiments show that, controlled and careful experimental conditions, relative uncertainties are about 20% for flow rates in sewer pipes, 6-10% for volumes, 25-35% for TSS concentrations and loads, and 18-276% for TSS removal rates. In order to evaluate the annual pollutant interception efficiency of storage and settling tanks with a given uncertainty, efforts should first be devoted to decrease the sampling uncertainty by increasing the number of sampled events.

  5. Total lead (Pb) concentration in oil shale ash samples based on correlation to isotope Pb-210 gamma-spectrometric measurements

    Energy Technology Data Exchange (ETDEWEB)

    Vaasma, T.; Kiisk, M.; Tkaczyk, A.H. [University of Tartu (Estonia); Bitjukova, L. [Tallinn University of Technology (Estonia)

    2014-07-01

    (PF) and circulating fluidized bed (CFB) firing technology. These samples were analyzed to determine macro and trace elements by the ICP-MS method. The same samples were also measured with a high-purity germanium detector (planar BSI GPD-50400) to determine the activity concentrations of natural radionuclides. The lead concentrations and Pb-210 activity concentrations were determined, and the correlation between the corresponding values was analyzed. Initial results demonstrate a strong positive linear relationship between these values, with the coefficient of determination (R{sup 2}) over 94. The correlation coefficient (Pearson's, 'r') had a value over 0.95. Both Pb and Pb-210 values had an increasing trend from the bottom ash towards electrostatic precipitator (ESP) ashes. The strong linear correlation between Pb concentrations and Pb-210 activity concentrations gives a credible indication that lead can be measured in ash samples using its radioactive isotope Pb-210. Especially in situations where there are higher concentrations of Pb, for example in the case of wastes from the metallurgic and energy industries, this method could be used to detect the lead concentration quickly and with no chemical processing of the sample. Document available in abstract form only. (authors)

  6. Analysis Of The Tank 6F Final Characterization Samples-2012

    International Nuclear Information System (INIS)

    Oji, L. N.; Diprete, D. P.; Coleman, C. J.; Hay, M. S.; Shine, E. P.

    2012-01-01

    The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) to provide sample preparation and analysis of the Tank 6F final characterization samples to determine the residual tank inventory prior to grouting. Fourteen residual Tank 6F solid samples from three areas on the floor of the tank were collected and delivered to SRNL between May and August 2011. These Tank 6F samples were homogenized and combined into three composite samples based on a proportion compositing scheme and the resulting composite samples were analyzed for radiological, chemical and elemental components. Additional measurements performed on the Tank 6F composite samples include bulk density and water leaching of the solids to account for water soluble components. The composite Tank 6F samples were analyzed and the data reported in triplicate. Sufficient quality assurance standards and blanks were utilized to demonstrate adequate characterization of the Tank 6F samples. The main evaluation criteria were target detection limits specified in the technical task request document. While many of the target detection limits were met for the species characterized for Tank 6F some were not met. In a few cases, the relatively high levels of radioactive species of the same element or a chemically similar element precluded the ability to measure some isotopes to low levels. The isotopes whose detection limits were not met in all cases included Sn-126, Sb-126, Sb-126m, Eu-152, Cm-243 and Cf-249. SRNL, in conjunction with the customer, reviewed all of these cases and determined that the impacts of not meeting the target detection limits were acceptable. Based on the analyses of variance (ANOVA) for the inorganic constituents of Tank 6F, all the inorganic constituents displayed heterogeneity. The inorganic results demonstrated consistent differences across the composite samples: lowest concentrations for Composite Sample 1, intermediate-valued concentrations for Composite

  7. Analysis of the Tank 6F Final Characterization Samples-2012

    International Nuclear Information System (INIS)

    Oji, L. N.; Diprete, D. P.; Coleman, C. J.; Hay, M. S.; Shine, E. P.

    2013-01-01

    The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) to provide sample preparation and analysis of the Tank 6F final characterization samples to determine the residual tank inventory prior to grouting. Fourteen residual Tank 6F solid samples from three areas on the floor of the tank were collected and delivered to SRNL between May and August 2011. These Tank 6F samples were homogenized and combined into three composite samples based on a proportion compositing scheme and the resulting composite samples were analyzed for radiological, chemical and elemental components. Additional measurements performed on the Tank 6F composite samples include bulk density and water leaching of the solids to account for water soluble components. The composite Tank 6F samples were analyzed and the data reported in triplicate. Sufficient quality assurance standards and blanks were utilized to demonstrate adequate characterization of the Tank 6F samples. The main evaluation criteria were target detection limits specified in the technical task request document. While many of the target detection limits were met for the species characterized for Tank 6F some were not met. In a few cases, the relatively high levels of radioactive species of the same element or a chemically similar element precluded the ability to measure some isotopes to low levels. The isotopes whose detection limits were not met in all cases included Sn-126, Sb-126, Sb-126m, Eu-152, Cm- 243 and Cf-249. SRNL, in conjunction with the customer, reviewed all of these cases and determined that the impacts of not meeting the target detection limits were acceptable. Based on the analyses of variance (ANOVA) for the inorganic constituents of Tank 6F, all the inorganic constituents displayed heterogeneity. The inorganic results demonstrated consistent differences across the composite samples: lowest concentrations for Composite Sample 1, intermediate-valued concentrations for Composite

  8. ANALYSIS OF THE TANK 6F FINAL CHARACTERIZATION SAMPLES-2012

    Energy Technology Data Exchange (ETDEWEB)

    Oji, L.; Diprete, D.; Coleman, C.; Hay, M.; Shine, G.

    2012-06-28

    The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) to provide sample preparation and analysis of the Tank 6F final characterization samples to determine the residual tank inventory prior to grouting. Fourteen residual Tank 6F solid samples from three areas on the floor of the tank were collected and delivered to SRNL between May and August 2011. These Tank 6F samples were homogenized and combined into three composite samples based on a proportion compositing scheme and the resulting composite samples were analyzed for radiological, chemical and elemental components. Additional measurements performed on the Tank 6F composite samples include bulk density and water leaching of the solids to account for water soluble components. The composite Tank 6F samples were analyzed and the data reported in triplicate. Sufficient quality assurance standards and blanks were utilized to demonstrate adequate characterization of the Tank 6F samples. The main evaluation criteria were target detection limits specified in the technical task request document. While many of the target detection limits were met for the species characterized for Tank 6F some were not met. In a few cases, the relatively high levels of radioactive species of the same element or a chemically similar element precluded the ability to measure some isotopes to low levels. The isotopes whose detection limits were not met in all cases included Sn-126, Sb-126, Sb-126m, Eu-152, Cm-243 and Cf-249. SRNL, in conjunction with the customer, reviewed all of these cases and determined that the impacts of not meeting the target detection limits were acceptable. Based on the analyses of variance (ANOVA) for the inorganic constituents of Tank 6F, all the inorganic constituents displayed heterogeneity. The inorganic results demonstrated consistent differences across the composite samples: lowest concentrations for Composite Sample 1, intermediate-valued concentrations for Composite

  9. Analysis of the Tank 6F Final Characterization Samples-2012

    Energy Technology Data Exchange (ETDEWEB)

    Oji, L. N.; Diprete, D. P.; Coleman, C. J.; Hay, M. S.; Shine, E. P.

    2013-01-31

    The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) to provide sample preparation and analysis of the Tank 6F final characterization samples to determine the residual tank inventory prior to grouting. Fourteen residual Tank 6F solid samples from three areas on the floor of the tank were collected and delivered to SRNL between May and August 2011. These Tank 6F samples were homogenized and combined into three composite samples based on a proportion compositing scheme and the resulting composite samples were analyzed for radiological, chemical and elemental components. Additional measurements performed on the Tank 6F composite samples include bulk density and water leaching of the solids to account for water soluble components. The composite Tank 6F samples were analyzed and the data reported in triplicate. Sufficient quality assurance standards and blanks were utilized to demonstrate adequate characterization of the Tank 6F samples. The main evaluation criteria were target detection limits specified in the technical task request document. While many of the target detection limits were met for the species characterized for Tank 6F some were not met. In a few cases, the relatively high levels of radioactive species of the same element or a chemically similar element precluded the ability to measure some isotopes to low levels. The isotopes whose detection limits were not met in all cases included Sn-126, Sb-126, Sb-126m, Eu-152, Cm- 243 and Cf-249. SRNL, in conjunction with the customer, reviewed all of these cases and determined that the impacts of not meeting the target detection limits were acceptable. Based on the analyses of variance (ANOVA) for the inorganic constituents of Tank 6F, all the inorganic constituents displayed heterogeneity. The inorganic results demonstrated consistent differences across the composite samples: lowest concentrations for Composite Sample 1, intermediate-valued concentrations for Composite

  10. Analysis Of The Tank 6F Final Characterization Samples-2012

    Energy Technology Data Exchange (ETDEWEB)

    Oji, L. N.; Diprete, D. P.; Coleman, C. J.; Hay, M. S.; Shine, E. P.

    2012-09-27

    The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) to provide sample preparation and analysis of the Tank 6F final characterization samples to determine the residual tank inventory prior to grouting. Fourteen residual Tank 6F solid samples from three areas on the floor of the tank were collected and delivered to SRNL between May and August 2011. These Tank 6F samples were homogenized and combined into three composite samples based on a proportion compositing scheme and the resulting composite samples were analyzed for radiological, chemical and elemental components. Additional measurements performed on the Tank 6F composite samples include bulk density and water leaching of the solids to account for water soluble components. The composite Tank 6F samples were analyzed and the data reported in triplicate. Sufficient quality assurance standards and blanks were utilized to demonstrate adequate characterization of the Tank 6F samples. The main evaluation criteria were target detection limits specified in the technical task request document. While many of the target detection limits were met for the species characterized for Tank 6F some were not met. In a few cases, the relatively high levels of radioactive species of the same element or a chemically similar element precluded the ability to measure some isotopes to low levels. The isotopes whose detection limits were not met in all cases included Sn-126, Sb-126, Sb-126m, Eu-152, Cm-243 and Cf-249. SRNL, in conjunction with the customer, reviewed all of these cases and determined that the impacts of not meeting the target detection limits were acceptable. Based on the analyses of variance (ANOVA) for the inorganic constituents of Tank 6F, all the inorganic constituents displayed heterogeneity. The inorganic results demonstrated consistent differences across the composite samples: lowest concentrations for Composite Sample 1, intermediate-valued concentrations for Composite

  11. Laser-based measurements of 18O/16O stable isotope ratios (δ18O in wine samples

    Directory of Open Access Journals (Sweden)

    Gupta M

    2013-09-01

    Full Text Available Manish Gupta,1 J Brian Leen,1 Elena Simone Franklin Berman,1 Aldo Ciambotti2 1Los Gatos Research, Mountain View, CA, USA; 2Consiglio per la Ricerca e la Sperimentazione in Agricoltura, Centro di Ricerca per l'Enologia, Asti, Italy Abstract: Wine counterfeiting is an international, multi-billion dollar issue, with some estimates suggesting that up to 5% of wines sold at auctions or secondary markets are fraudulent. Isotope ratio mass spectrometer (IRMS measurements of the 18O/16O stable isotope ratio (δ18O of water-in-wine have been used for wine authentication; however, these analyses are time-consuming and costly. In this preliminary study, off-axis integrated cavity output spectroscopy (OA-ICOS is used to quantify δ18O in wines. This laser-based method has been extensively used to study water isotopes for hydrological and medical applications. Recently, the development of a spectral contaminant identifier (SCI has extended the application of these OA-ICOS analyzers to contaminated water samples (eg, plant, soil, and leaf waters. Here, we utilize OA-ICOS with the SCI to characterize wine samples (9%–15% ethanol, and show that the laser-based instrument provides a δ18O measurement precision of ±0.07‰ (1σ and agrees with IRMS to within ±0.63‰ (1σ. Moreover, by training the SCI on isotopically-characterized wines, the agreement with IRMS improves to within ±0.30‰ (1σ. The utility of the instrument is demonstrated by measuring watered and mixed wines. The method presented here can be readily extended to address other food authentication applications. Keywords: wine isotopes, wine fraud, counterfeit wines, OA-ICOS

  12. Sensor-triggered sampling to determine instantaneous airborne vapor exposure concentrations.

    Science.gov (United States)

    Smith, Philip A; Simmons, Michael K; Toone, Phillip

    2018-06-01

    It is difficult to measure transient airborne exposure peaks by means of integrated sampling for organic chemical vapors, even with very short-duration sampling. Selection of an appropriate time to measure an exposure peak through integrated sampling is problematic, and short-duration time-weighted average (TWA) values obtained with integrated sampling are not likely to accurately determine actual peak concentrations attained when concentrations fluctuate rapidly. Laboratory analysis for integrated exposure samples is preferred from a certainty standpoint over results derived in the field from a sensor, as a sensor user typically must overcome specificity issues and a number of potential interfering factors to obtain similarly reliable data. However, sensors are currently needed to measure intra-exposure period concentration variations (i.e., exposure peaks). In this article, the digitized signal from a photoionization detector (PID) sensor triggered collection of whole-air samples when toluene or trichloroethylene vapors attained pre-determined levels in a laboratory atmosphere generation system. Analysis by gas chromatography-mass spectrometry of whole-air samples (with both 37 and 80% relative humidity) collected using the triggering mechanism with rapidly increasing vapor concentrations showed good agreement with the triggering set point values. Whole-air samples (80% relative humidity) in canisters demonstrated acceptable 17-day storage recoveries, and acceptable precision and bias were obtained. The ability to determine exceedance of a ceiling or peak exposure standard by laboratory analysis of an instantaneously collected sample, and to simultaneously provide a calibration point to verify the correct operation of a sensor was demonstrated. This latter detail may increase the confidence in reliability of sensor data obtained across an entire exposure period.

  13. Integrated sampling vs ion chromatography: Mathematical considerations

    International Nuclear Information System (INIS)

    Sundberg, L.L.

    1992-01-01

    This paper presents some general purpose considerations that can be utilized when comparisons are made between the results of integrated sampling over several hours or days, and ion chromatography where sample collection times are measured in minutes. The discussion is geared toward the measurement of soluble transition metal ions in BWR feedwater. Under steady-state conditions, the concentrations reported by both techniques should be in reasonable agreement. Transient operations effect both types of measurements. A simplistic model, applicable to both sampling techniques, is presented that demonstrates the effect of transients which occur during the acquisition of a steady-state sample. For a common set of conditions, the integrated concentration is proportional to the concentration and duration of the transient, and inversely proportional to the sample collection time. The adjustment of the collection period during a known transient allows an estimation of peak transient concentration. Though the probability of sampling a random transient with the integrated sampling technique is very high, the magnitude is severely diluted with long integration times. Transient concentrations are magnified with ion chromatography, but the probability of sampling a transient is significantly lower using normal ion chromatography operations. Various data averaging techniques are discussed for integrated sampling and IC determinations. The use of time-weighted averages appears to offer more advantages over arithmetic and geometric means for integrated sampling when the collection period is variable. For replicate steady-state ion chromatography determinations which bracket a transient sample, it may be advantageous to ignore the calculation of averages, and report the data as trending information only

  14. Self-absorption corrections for gamma ray spectral measurements of 210Pb in environmental samples

    International Nuclear Information System (INIS)

    Miller, K.M.

    1987-01-01

    Theoretical considerations and experimental data are used to demonstrate the basic behaviour of the self-absorption effect of a sample matrix in gamma ray spectrometry, particularly as it relates to the analysis of 210 Pb in environmental media. The results indicate that it may not be appropriate to apply the commonly used self-absorption function in all cases. (orig.)

  15. Improved technical success and radiation safety of adrenal vein sampling using rapid, semi-quantitative point-of-care cortisol measurement.

    Science.gov (United States)

    Page, Michael M; Taranto, Mario; Ramsay, Duncan; van Schie, Greg; Glendenning, Paul; Gillett, Melissa J; Vasikaran, Samuel D

    2018-01-01

    Objective Primary aldosteronism is a curable cause of hypertension which can be treated surgically or medically depending on the findings of adrenal vein sampling studies. Adrenal vein sampling studies are technically demanding with a high failure rate in many centres. The use of intraprocedural cortisol measurement could improve the success rates of adrenal vein sampling but may be impracticable due to cost and effects on procedural duration. Design Retrospective review of the results of adrenal vein sampling procedures since commencement of point-of-care cortisol measurement using a novel single-use semi-quantitative measuring device for cortisol, the adrenal vein sampling Accuracy Kit. Success rate and complications of adrenal vein sampling procedures before and after use of the adrenal vein sampling Accuracy Kit. Routine use of the adrenal vein sampling Accuracy Kit device for intraprocedural measurement of cortisol commenced in 2016. Results Technical success rate of adrenal vein sampling increased from 63% of 99 procedures to 90% of 48 procedures ( P = 0.0007) after implementation of the adrenal vein sampling Accuracy Kit. Failure of right adrenal vein cannulation was the main reason for an unsuccessful study. Radiation dose decreased from 34.2 Gy.cm 2 (interquartile range, 15.8-85.9) to 15.7 Gy.cm 2 (6.9-47.3) ( P = 0.009). No complications were noted, and implementation costs were minimal. Conclusions Point-of-care cortisol measurement during adrenal vein sampling improved cannulation success rates and reduced radiation exposure. The use of the adrenal vein sampling Accuracy Kit is now standard practice at our centre.

  16. Bias of shear wave elasticity measurements in thin layer samples and a simple correction strategy.

    Science.gov (United States)

    Mo, Jianqiang; Xu, Hao; Qiang, Bo; Giambini, Hugo; Kinnick, Randall; An, Kai-Nan; Chen, Shigao; Luo, Zongping

    2016-01-01

    Shear wave elastography (SWE) is an emerging technique for measuring biological tissue stiffness. However, the application of SWE in thin layer tissues is limited by bias due to the influence of geometry on measured shear wave speed. In this study, we investigated the bias of Young's modulus measured by SWE in thin layer gelatin-agar phantoms, and compared the result with finite element method and Lamb wave model simulation. The result indicated that the Young's modulus measured by SWE decreased continuously when the sample thickness decreased, and this effect was more significant for smaller thickness. We proposed a new empirical formula which can conveniently correct the bias without the need of using complicated mathematical modeling. In summary, we confirmed the nonlinear relation between thickness and Young's modulus measured by SWE in thin layer samples, and offered a simple and practical correction strategy which is convenient for clinicians to use.

  17. Method for measuring the decay rate of a radionuclide emitting β-rays in a liquid sample

    International Nuclear Information System (INIS)

    Horrocks, D.

    1977-01-01

    With this method the decay rate of a radionuclide emitting β-rays, e.g. 3 H or 14 C, in a liquid sample can be measured by means of liquid scintillation counters, at least two different versions of the sample being used with quench effect (shifting of the Compton spectrum). For this purpose each sample is counted with and without a radioactive standard source, e.g. 137 Cs. Then a pulse height will be determined corresponding to a selected point in the pulse height spectrum if the standard source is present. The determination of a zero-threshold sample count rate is then performed by counting the sample in a counting window. In addition standardized values of the measured pulse heights are derived and put in mathematical relation to corresponding pulse count rates, the pulse count rate for a standardized pulse height value thus becoming zero and the sample decay rate in this way being determined. (DG) 891 HP [de

  18. Si(Li)-NaI(Tl) sandwich detector array for measurements of trace radionuclides in soil samples

    International Nuclear Information System (INIS)

    Strauss, M.G.; Sherman, I.S.; Roche, C.T.; Pehl, R.H.

    1986-01-01

    An ultra-sensitive X/γ-ray detector system for assaying trace radioactivity in actinide contaminated soil and ash samples has been developed. The new system consists of an array of 6 large Si(Li) X-ray detectors sensitive on both faces and mounted on edge in a paddle-shaped cryostat with a 14 cm diameter Be window on each side. The paddle, with a sample of the soil placed at each window, is sandwiched between 2 large NaI(Tl) scintillators which suppress the γ background. With X-rays being measured simultaneously from soil in 2 sample holders and background reduced by 50% using anticoincidence, the sensitivity of this detector is 4 times higher than that of conventionally mounted Si(Li) detectors. A soil sample containing 50 pCi/g 239 Pu was measured in 5 min with an uncertainty of 1 and NpLsub(β1) X-ray peaks are resolved thus permitting measurement of trace Pu in the presence of 241 Am. This is the most sensitive and selective detector known for nondestructive assay of radioactivity in soil and other samples. (orig.)

  19. Relations among behavioral and questionnaire measures of impulsivity in a sample of suicide attempters.

    Science.gov (United States)

    Bagge, Courtney L; Littlefield, Andrew K; Rosellini, Anthony J; Coffey, Scott F

    2013-08-01

    Despite the focus on impulsivity within suicide research, it remains unclear the extent to which impulsivity assessments, that purportedly tap similar constructs, show significant overlap in samples of individuals with suicidal behaviors. In a sample of 69 suicide attempters, we took a multitrait, multimethod approach to examine the relation among various questionnaire and behavioral assessments of impulsivity facets. With the exception of urgency and go-stop performance, there was little evidence of concordance between questionnaire and behavioral measures. These findings suggest researchers cannot presume that measures of "impulsivity" assess similar psychological processes and that more nuanced terminology is needed. © 2013 The American Association of Suicidology.

  20. Note: A simple image processing based fiducial auto-alignment method for sample registration.

    Science.gov (United States)

    Robertson, Wesley D; Porto, Lucas R; Ip, Candice J X; Nantel, Megan K T; Tellkamp, Friedjof; Lu, Yinfei; Miller, R J Dwayne

    2015-08-01

    A simple method for the location and auto-alignment of sample fiducials for sample registration using widely available MATLAB/LabVIEW software is demonstrated. The method is robust, easily implemented, and applicable to a wide variety of experiment types for improved reproducibility and increased setup speed. The software uses image processing to locate and measure the diameter and center point of circular fiducials for distance self-calibration and iterative alignment and can be used with most imaging systems. The method is demonstrated to be fast and reliable in locating and aligning sample fiducials, provided here by a nanofabricated array, with accuracy within the optical resolution of the imaging system. The software was further demonstrated to register, load, and sample the dynamically wetted array.

  1. Field demonstration of technologies for delineating uranium contaminated soils

    International Nuclear Information System (INIS)

    Tidwell, V.C.; Cunnane, J.C.; Schwing, J.; Lee, S.Y.; Perry, D.L.; Morris, D.E.

    1993-01-01

    An Integrated Demonstration Program, hosted by the Fernald Environmental Restoration Management Corporation (FERMCO), has been established for investigating technologies applicable to the characterization and remediation of soils contaminated with uranium. An important part of this effort is the evaluation of field screening tools capable of acquiring high resolution information on the distribution of uranium contamination in surface soils in a cost-and-time efficient manner. Consistent with this need, four field screening technologies have been demonstrated at two hazardous waste sites at the FERMCO. The four technologies tested are wide-area gamma spectroscopy, beta scintillation counting, laser ablation-inductively coupled plasma-atomic emission spectroscopy (LA-ICP-AES), and long-range alpha detection (LRAD). One of the important findings of this demonstration was just how difficult it is to compare data collected by means of multiple independent measurement techniques. Difficulties are attributed to differences in measurement scale, differences in the basic physics upon which the various measurement schemes are predicated, and differences in the general performance of detector instrumentation. It follows that optimal deployment of these techniques requires the development of an approach for accounting for the intrinsic differences noted above. As such, emphasis is given in this paper to the development of a methodology for integrating these techniques for use in site characterization programs as well as the development of a framework for interpreting the collected data. The methodology described here also has general application to other field-based screening technologies and soil sampling programs

  2. Alpha liquid-scintillation spectrometry used for the measurement of uranium/thorium-disequilibria in soil samples

    International Nuclear Information System (INIS)

    Fueeg, B.; Tschachtli, T.; Kraehenbuehl, U.

    1997-01-01

    For the measurements of low-level radioactivity of natural samples. It is of interest to have a system with high counting efficiency. Alpha liquid-scintillation spectrometry is attractive, because it offers a 4 π geometry. Some chemical separation can be obtained using extractive scintillators. Due to quenching problems for natural samples, additional separation power is needed. A new sample preparation method was developed employing extraction chromatographic resin for measuring 238 U, 234 U, 232 Th, 230 Th, 228 Th and 226 Ra in soil samples, without using any uranium- or thorium-tracer for determining the chemical yields. This method was tested by analyzing the two different reference materials, IAEA-375, soil from Tschernobyl, as well as IAEA SDA-1, a deep-sea sediment with a high calcium content. For all analyzed radionuclides the recoveries were better than 90% with errors (confidence level of 95%) smaller than 5%. The minimal detectable concentration ranges between 0.2 and 0.8 Bq/kg, based on a one gram aliquot of sample and 80'000 seconds counting time. (orig.)

  3. New methodological approaches to the simultaneous measurement of the 90Sr and 137Cs activity in environmental samples

    Directory of Open Access Journals (Sweden)

    M. V. Zheltonozhska

    2012-12-01

    Full Text Available Nonradiochemical method of measurement of 90Sr and137Cs activity in environmental samples is proposed. This method is based on spectrometrical investigation of electrons accompanied the decay of the 90Sr and137Cs. Accounting for the contribution to the total activity of the samples from the zones with the density of the contamination 1 - 5 Кu/km2 the 40K electrons allowed to improve the accuracy of the measurements for the samples of small rodents up to 15 - 20 % (the ratio of A (137Cs/A (90Sr was from 2 to 100, for samples of soil up to 10 - 15 % (the change of activity in these samples was ten thousand times. The results of the spectrometric measurements were confirmed by the traditional radiochemical research.

  4. Acceptance sampling using judgmental and randomly selected samples

    Energy Technology Data Exchange (ETDEWEB)

    Sego, Landon H.; Shulman, Stanley A.; Anderson, Kevin K.; Wilson, John E.; Pulsipher, Brent A.; Sieber, W. Karl

    2010-09-01

    We present a Bayesian model for acceptance sampling where the population consists of two groups, each with different levels of risk of containing unacceptable items. Expert opinion, or judgment, may be required to distinguish between the high and low-risk groups. Hence, high-risk items are likely to be identifed (and sampled) using expert judgment, while the remaining low-risk items are sampled randomly. We focus on the situation where all observed samples must be acceptable. Consequently, the objective of the statistical inference is to quantify the probability that a large percentage of the unsampled items in the population are also acceptable. We demonstrate that traditional (frequentist) acceptance sampling and simpler Bayesian formulations of the problem are essentially special cases of the proposed model. We explore the properties of the model in detail, and discuss the conditions necessary to ensure that required samples sizes are non-decreasing function of the population size. The method is applicable to a variety of acceptance sampling problems, and, in particular, to environmental sampling where the objective is to demonstrate the safety of reoccupying a remediated facility that has been contaminated with a lethal agent.

  5. NID Copper Sample Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kouzes, Richard T.; Zhu, Zihua

    2011-02-01

    The current focal point of the nuclear physics program at PNNL is the MAJORANA DEMONSTRATOR, and the follow-on Tonne-Scale experiment, a large array of ultra-low background high-purity germanium detectors, enriched in 76Ge, designed to search for zero-neutrino double-beta decay (0νββ). This experiment requires the use of germanium isotopically enriched in 76Ge. The DEMONSTRATOR will utilize 76Ge from Russia, but for the Tonne-Scale experiment it is hoped that an alternate technology under development at Nonlinear Ion Dynamics (NID) will be a viable, US-based, lower-cost source of separated material. Samples of separated material from NID require analysis to determine the isotopic distribution and impurities. The MAJORANA DEMONSTRATOR is a DOE and NSF funded project with a major science impact. DOE is funding NID through an SBIR grant for development of their separation technology for application to the Tonne-Scale experiment. The Environmental Molecular Sciences facility (EMSL), a DOE user facility at PNNL, has the required mass spectroscopy instruments for making these isotopic measurements that are essential to the quality assurance for the MAJORANA DEMONSTRATOR and for the development of the future separation technology required for the Tonne-Scale experiment. A sample of isotopically separated copper was provided by NID to PNNL for isotopic analysis as a test of the NID technology. The results of that analysis are reported here.

  6. NID Copper Sample Analysis

    International Nuclear Information System (INIS)

    Kouzes, Richard T.; Zhu, Zihua

    2011-01-01

    The current focal point of the nuclear physics program at PNNL is the MAJORANA DEMONSTRATOR, and the follow-on Tonne-Scale experiment, a large array of ultra-low background high-purity germanium detectors, enriched in 76 Ge, designed to search for zero-neutrino double-beta decay (0νββ). This experiment requires the use of germanium isotopically enriched in 76 Ge. The DEMONSTRATOR will utilize 76 Ge from Russia, but for the Tonne-Scale experiment it is hoped that an alternate technology under development at Nonlinear Ion Dynamics (NID) will be a viable, US-based, lower-cost source of separated material. Samples of separated material from NID require analysis to determine the isotopic distribution and impurities. The MAJORANA DEMONSTRATOR is a DOE and NSF funded project with a major science impact. DOE is funding NID through an SBIR grant for development of their separation technology for application to the Tonne-Scale experiment. The Environmental Molecular Sciences facility (EMSL), a DOE user facility at PNNL, has the required mass spectroscopy instruments for making these isotopic measurements that are essential to the quality assurance for the MAJORANA DEMONSTRATOR and for the development of the future separation technology required for the Tonne-Scale experiment. A sample of isotopically separated copper was provided by NID to PNNL for isotopic analysis as a test of the NID technology. The results of that analysis are reported here.

  7. Improved optimum condition for recovery and measurement of 210Po in environmental samples

    International Nuclear Information System (INIS)

    Zal Uyun Wan Mahmood; Norfaizal Mohamed; Nik Azlin Nik Ariffin; Abdul Kadir Ishak

    2012-01-01

    An improved laboratory technique for measurement of polonium-210( 210 Po) in environmental samples has been developed in Radiochemistry and Environmental Laboratory (RAS), Malaysian Nuclear Agency. To further improve this technique, a study with the objectives to determine the optimum conditions for 210 Po deposition and; evaluate the accuracy and precision results for the determination of 210 Po in environmental samples was carried-out. Polonium-210 which is an alpha emitter obtained in acidic solution through total digestion and dissolution of samples has been efficiently plated onto one side of the silver disc in the spontaneous plating process for measurement of its alpha activity. The optimum conditions for deposition of 210 Po were achieved using hydrochloric acid (HCl) media at acidity of 0.5 M with the presence of 1.0 gram hydroxyl ammonium chloride and the plating temperature at 90 degree Celsius. The plating was carried out in 80 ml HCl solution (0.5 M) for 4 hours. The recorded recoveries obtained using 209 Po tracers in the CRM IAEA-385 and environmental samples were 85 % - 98% whereby the efficiency of the new technique is a distinct advantage over the existing techniques. Therefore, optimization of deposition parameters is a prime importance to achieve accuracy and precision results as well as economy and time saving. (author)

  8. A study to confirm the reliability and construct validity of an organisational citizenship behaviour measure on a South African sample

    Directory of Open Access Journals (Sweden)

    Bright Mahembe

    2015-10-01

    Research purpose: The primary goal of the study was to validate the Organisational Citizenship Behaviour Scale (OCBS developed by Podsakoff, Mackenzie, Moorman and Fetter (1990 on a South African sample. Motivation for the study: Organisational citizenship behaviour is one of the important workplace outcomes. A psychometrically sound instrument is therefore required. Research design, approach and method: The sample consisted of 503 employees from the educational sector in the Eastern and Western Cape Provinces of South Africa. The OCBS was used to measure organisational citizenship behaviour. Main findings: High levels of reliability were found for the OCBS sub-scales. The first and second-order measurement models of the OCBS showed good fit. A competing one-factor model did not show good model fit. In terms of discriminant validity four of the five subdimensions correlated highly. Practical/managerial implications: Although the OCBS demonstrated some sound reliability coefficients and reasonable construct validity, the discriminant validity of four of the subscales raise some questions which future studies should confirm. The use of the instrument should help to continue to measure the much-needed extra-role behaviours that mirror an employee’s interest in the success of the organisation. Contribution/value-add: The study contributes to the requirements of the Employment Equity Act (No. 55 of 1998 and the Amended Employment Equity Act of South Africa (Republic of South Africa, 1998; 2014. This promotes the use of reliable and valid instruments in South Africa by confirming the psychometric properties of the OCBS.

  9. A blueprint for demonstrating quantum supremacy with superconducting qubits

    Science.gov (United States)

    Neill, C.; Roushan, P.; Kechedzhi, K.; Boixo, S.; Isakov, S. V.; Smelyanskiy, V.; Megrant, A.; Chiaro, B.; Dunsworth, A.; Arya, K.; Barends, R.; Burkett, B.; Chen, Y.; Chen, Z.; Fowler, A.; Foxen, B.; Giustina, M.; Graff, R.; Jeffrey, E.; Huang, T.; Kelly, J.; Klimov, P.; Lucero, E.; Mutus, J.; Neeley, M.; Quintana, C.; Sank, D.; Vainsencher, A.; Wenner, J.; White, T. C.; Neven, H.; Martinis, J. M.

    2018-04-01

    A key step toward demonstrating a quantum system that can address difficult problems in physics and chemistry will be performing a computation beyond the capabilities of any classical computer, thus achieving so-called quantum supremacy. In this study, we used nine superconducting qubits to demonstrate a promising path toward quantum supremacy. By individually tuning the qubit parameters, we were able to generate thousands of distinct Hamiltonian evolutions and probe the output probabilities. The measured probabilities obey a universal distribution, consistent with uniformly sampling the full Hilbert space. As the number of qubits increases, the system continues to explore the exponentially growing number of states. Extending these results to a system of 50 qubits has the potential to address scientific questions that are beyond the capabilities of any classical computer.

  10. A comparison between the measurements of Kr-85 in environmental samples by liquid scintillation and proportional counters

    International Nuclear Information System (INIS)

    Heras Iniquez, M.C.; Perez Garcia, M.M.

    1983-01-01

    The most used methods for the measurement of Kr-81 beta-activity after their concentration and aisolation are the liquid scintillation counting and the proportional counter. In this work the beta activity of concentrated and aisolated Kr-85 samples measured in collaboration with the Max-Planck Institut fur Kernphyslk, Aussenstelle Freiburg. Samples taken both In Madrid and Frelburg are measured by proportional counters in the Max-Planck lnstitut, Freibury and by liquid scintillation counting in JEN, Madrid. The comparison of both measurements do not show appreciable discrepancy between the results obtained to both techniques. (Author)

  11. Measurement of the Tracer Gradient and Sampling System Bias of the Hot Fuel Examination Facility Stack Air Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, John A.; Flaherty, Julia E.

    2011-07-20

    This report describes tracer gas uniformity and bias measurements made in the exhaust air discharge of the Hot Fuel Examination Facility at Idaho National Laboratory. The measurements were a follow-up on earlier measurements which indicated a lack of mixing of the two ventilation streams being discharged via a common stack. The lack of mixing is detrimental to the accuracy of air emission measurements. The lack of mixing was confirmed in these new measurements. The air sampling probe was found to be out of alignment and that was corrected. The suspected sampling bias in the air sample stream was disproved.

  12. Aragonite-Calcite Inversion During Biogenic Carbonate Sampling: Considerations for Interpreting Isotopic Measurements in Paleoclimate Studies

    Science.gov (United States)

    Waite, A. J.; Swart, P. K.

    2011-12-01

    As aragonite is the metastable polymorph of calcium carbonate, it lends itself to monotropic inversion to the more stable polymorph, calcite. This inversion is possible through an increase in the temperature and pressure conditions to which the sample is exposed and, although first noted nearly a century ago, has been primarily discussed in the context of sample roasting prior to analyses in paleoclimatological studies. Over the last several decades, however, researchers have found evidence to suggest that the friction associated with the sampling of biogenic carbonates via milling/drilling also induces inversion. Furthermore, this inversion may be associated with a shift in measured oxygen isotopic values and ultimately have significant implications for the interpretation of paleoclimatic reconstructions. Despite this, the isotopic heterogeneity of biogenic aragonite skeletons makes the effects of inversion challenging to test and the subject remains underrepresented in the literature. Here we present a first order study into the effects of milling on both the mineralogy and isotopic compositions measured in sclerosponges, corals, and molluscs. X-Ray diffraction analysis of samples hand ground with a mortar and pestle reveal 100% aragonitic skeletons. Conversely, samples milled with a computerized micromill show measurable inversion to calcite. On average, percent inversion of aragonite to calcite for individual specimens was 15% for sclerosponges, 16% for corals, and 9% for molluscs. Isotopic data from these specimens show that the higher the percentage of aragonite inverted to calcite, the more depleted the measured oxygen isotopic values. In the largest of the datasets (sclerosponges), it is evident that the range of oxygen isotope values from milled samples (-0.02 to +0.84%) exceeds the range in values for those samples which were hand ground and showed no inversion (+0.53 to +0.90%). This, coupled with the strong correlation between the two variables

  13. Utilizing photon number parity measurements to demonstrate quantum computation with cat-states in a cavity

    Science.gov (United States)

    Petrenko, A.; Ofek, N.; Vlastakis, B.; Sun, L.; Leghtas, Z.; Heeres, R.; Sliwa, K. M.; Mirrahimi, M.; Jiang, L.; Devoret, M. H.; Schoelkopf, R. J.

    2015-03-01

    Realizing a working quantum computer requires overcoming the many challenges that come with coupling large numbers of qubits to perform logical operations. These include improving coherence times, achieving high gate fidelities, and correcting for the inevitable errors that will occur throughout the duration of an algorithm. While impressive progress has been made in all of these areas, the difficulty of combining these ingredients to demonstrate an error-protected logical qubit, comprised of many physical qubits, still remains formidable. With its large Hilbert space, superior coherence properties, and single dominant error channel (single photon loss), a superconducting 3D resonator acting as a resource for a quantum memory offers a hardware-efficient alternative to multi-qubit codes [Leghtas et.al. PRL 2013]. Here we build upon recent work on cat-state encoding [Vlastakis et.al. Science 2013] and photon-parity jumps [Sun et.al. 2014] by exploring the effects of sequential measurements on a cavity state. Employing a transmon qubit dispersively coupled to two superconducting resonators in a cQED architecture, we explore further the application of parity measurements to characterizing such a hybrid qubit/cat state architecture. In so doing, we demonstrate the promise of integrating cat states as central constituents of future quantum codes.

  14. Reliability of sampling strategies for measuring dairy cattle welfare on commercial farms.

    Science.gov (United States)

    Van Os, Jennifer M C; Winckler, Christoph; Trieb, Julia; Matarazzo, Soraia V; Lehenbauer, Terry W; Champagne, John D; Tucker, Cassandra B

    2018-02-01

    Our objective was to evaluate how the proportion of high-producing lactating cows sampled on each farm and the selection method affect prevalence estimates for animal-based measures. We assessed the entire high-producing pen (days in milk size calculations from the Welfare Quality Protocol; and (4) selecting the first, middle, or final third of cows exiting the milking parlor. Estimates were compared with true values using regression analysis and were considered accurate if they met 3 criteria: the coefficient of determination was ≥0.9 and the slope and intercept did not differ significantly from 1 and 0, respectively. All estimates met the slope and intercept criteria, whereas the coefficient of determination increased when more cows were sampled. All estimates were accurate for neck alterations, ocular discharge (22.2 ± 27.4%), and carpal joint hair loss (14.1 ± 17.4%). Selecting a third of the milking order or using the Welfare Quality sample size calculations failed to accurately estimate all measures simultaneously. However, all estimates were accurate when selecting at least 2 of every 3 cows locked at the feed bunk. Using restraint position at the feed bunk did not differ systematically from computer-selecting the same proportion of cows randomly, and the former may be a simpler approach for welfare assessments. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  15. Dentoskeletal Overjet Measurements of Iraqi Adult Sample with Different Skeletal Jaw Relationship

    Directory of Open Access Journals (Sweden)

    Shahbaa A Mohammed

    2017-11-01

    Full Text Available Background: Many attempts were done to develop a method that actually reflects the sagittal jaw discrepancies without depending on cranial landmarks or dental occlusion. This study aimed to use one of these methods (dentoskeletal overjet for assessing the sagittal jaw relationships of Iraqi adult sample with different skeletal jaw relationship. Materials and method: The sample consisted of 90 digital true lateral cephalometric radiographs of Iraqi individuals with no previous orthodontic treatment. Cephalometric analysis of skeletal sagittal jaw relationship -ANB angle, beta angle and Wits appraisal- will perform for everyone to divide the sample into three groups (skeletal class I, II, III for which the dentoskeletal overjet will be measured. All cephalometric measurements will be done using AutoCAD. Results: Descriptive statistics of all variables with different skeletal jaw relationship showed that mean values of dentoskeletal overjet were (1.15, 3.91 and –2.01 mm for skeletal class I, class II and class III jaw relationship respectively. Accurate reproducibility of dentoskeletal overjet in assessment of jaw skeletal relationship showed that the lowest value was for assessment of skeletal class III jaw relationship (73% and the value for assessment of both skeletal class I and class II was higher (93%. Conclusions: Dentoskeletal overjet could be utilized in accurate representation of skeletal jaw relationship.

  16. The isotopic composition of methane in the stratosphere: high-altitude balloon sample measurements

    Directory of Open Access Journals (Sweden)

    T. Röckmann

    2011-12-01

    Full Text Available The isotopic composition of stratospheric methane has been determined on a large suite of air samples from stratospheric balloon flights covering subtropical to polar latitudes and a time period of 16 yr. 154 samples were analyzed for δ13C and 119 samples for δD, increasing the previously published dataset for balloon borne samples by an order of magnitude, and more than doubling the total available stratospheric data (including aircraft samples published to date. The samples also cover a large range in mixing ratio from tropospheric values near 1800 ppb down to only 250 ppb, and the strong isotope fractionation processes accordingly increase the isotopic composition up to δ13C = −14‰ and δD = +190‰, the largest enrichments observed for atmospheric CH4 so far. When analyzing and comparing kinetic isotope effects (KIEs derived from single balloon profiles, it is necessary to take into account the residence time in the stratosphere in combination with the observed mixing ratio and isotope trends in the troposphere, and the range of isotope values covered by the individual profile. The isotopic composition of CH4 in the stratosphere is affected by both chemical and dynamical processes. This severely hampers interpretation of the data in terms of the relative fractions of the three important sink mechanisms (reaction with OH, O(1D and Cl. It is shown that a formal sink partitioning using the measured data severely underestimates the fraction removed by OH, which is likely due to the insensitivity of the measurements to the kinetic fractionation in the lower stratosphere. Full quantitative interpretation of the CH4 isotope data in terms of the three sink reactions requires a global model.

  17. Measurement of the loss on ignition of bulk calcined bauxite samples by neutron moderation

    International Nuclear Information System (INIS)

    Aylmer, J.A.; Borsaru, M.

    1985-01-01

    The production of high-grade calcined bauxite is very dependent on the moisture content of the final product. Existing procedures rely on the ignition of small samples to monitor the effectiveness of the calcination process. The results obtained by this gravimetric technique are several hours behind production and do not permit regular adjustment of the furnace to optimize the control of the chemically bound water content (LOI). To provide rapid and more relevant results, a neutron moderation technique has been developed for measuring the LOI of bulk samples of calcined bauxite while they are still hot. The method uses fast neutrons from an 241 Am-Be neutron source to irradiate the samples, and the backscattered thermal neutrons detected are a measure of bound moisture content. The rms deviation between neutron and conventional determinations of LOI, in 15 calcined bauxite samples, was 0.08 per cent LOI over the range 0.1 to 0.9 per cent LOI. When allowance is made for the rms error in the ignition method, the error in the neutron method is found to be 0.07 per cent LOI

  18. Pronounceability: a measure of language samples based on children's mastery of the phonemes employed in them.

    Science.gov (United States)

    Whissell, Cynthia

    2003-06-01

    56 samples (n > half a million phonemes) of names (e.g., men's, women's jets'), song lyrics (e.g., Paul Simon's, rap, Beatles'), poems (frequently anthologized English poems), and children's materials (books directed at children ages 3-10 years) were used to study a proposed new measure of English language samples--Pronounceability-based on children's mastery of some phonemes in advance of others. This measure was provisionally equated with greater "youthfulness" and "playfulness" in language samples and with less "maturity." Findings include the facts that women's names were less pronounceable than men's and that poetry was less pronounceable than song lyrics or children's materials. In a supplementary study, 13 university student volunteers' assessments of the youth of randomly constructed names was linearly related to how pronounceable each name was (eta = .8), providing construct validity for the interpretation of Pronounceability as a measure of Youthfulness.

  19. Demonstration of spread-on peel-off consumer products for sampling surfaces contaminated with pesticides and chemical warfare agent signatures.

    Science.gov (United States)

    Behringer, Deborah L; Smith, Deborah L; Katona, Vanessa R; Lewis, Alan T; Hernon-Kenny, Laura A; Crenshaw, Michael D

    2014-08-01

    A terrorist attack using toxic chemicals is an international concern. The utility of rubber cement and latex body paint as spray-on/spread-on peel-off collection media for signatures attributable to pesticides and chemical warfare agents from interior building and public transportation surfaces two weeks post-deposition is demonstrated. The efficacy of these media to sample escalator handrail, stainless steel, vinyl upholstery fabric, and wood flooring is demonstrated for two pesticides and eight chemicals related to chemical warfare agents. The chemicals tested are nicotine, parathion, atropine, diisopropyl methylphosphonate, dimethyl methylphosphonate, dipinacolyl methylphosphonate, ethyl methylphosphonic acid, isopropyl methylphosphonic acid, methylphosphonic acid, and thiodiglycol. Amounts of each chemical found are generally greatest when latex body paint is used. Analytes with low volatility and containing an alkaline nitrogen or a sulfur atom (e.g., nicotine and parathion) usually are recovered to a greater extent than the neutral phosphonate diesters and acidic phosphonic acids (e.g., dimethyl methylphosphonate and ethyl methylphosphonic acid). Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. Techniques for sampling nuclear waste tank contents and in situ measurement of activity

    International Nuclear Information System (INIS)

    Lawrence, R.C.

    1978-04-01

    A study was conducted to develop suitable sampling equipment and techniques for characterizing the mechanical properties of nuclear wastes; identifying effective means of measuring radiation levels, temperatures, and neutron fluxes in situ in wastes; and developing a waste core sampler. A portable, stainless steel probe was developed which is placed in the tank through a riser. This probe is built for the insertion of instrumentation that can measure the contents of the tank at any level and take temperature, radiation, and neutron activation readings with reliable accuracy. A simple and reliable instrument for the in situ extraction of waste materials ranging from liquid to concrete-like substances was also developed. This portable, stainless steel waste core sampler can remove up to one liter of radioactive waste from tanks for transportation to hot cell laboratories for analysis of hardness, chemical form, and isotopic content. A cask for transporting the waste samples from the tanks to the laboratory under radiation-protected conditions was also fabricated. This cask was designed with a ''boot'' or inner-seal liner to contain any radioactive wastes that might remain on the outside of the waste core sampling device

  1. Application of a Dual-Arm Robot in Complex Sample Preparation and Measurement Processes.

    Science.gov (United States)

    Fleischer, Heidi; Drews, Robert Ralf; Janson, Jessica; Chinna Patlolla, Bharath Reddy; Chu, Xianghua; Klos, Michael; Thurow, Kerstin

    2016-10-01

    Automation systems with applied robotics have already been established in industrial applications for many years. In the field of life sciences, a comparable high level of automation can be found in the areas of bioscreening and high-throughput screening. Strong deficits still exist in the development of flexible and universal fully automated systems in the field of analytical measurement. Reasons are the heterogeneous processes with complex structures, which include sample preparation and transport, analytical measurements using complex sensor systems, and suitable data analysis and evaluation. Furthermore, the use of nonstandard sample vessels with various shapes and volumes results in an increased complexity. The direct use of existing automation solutions from bioscreening applications is not possible. A flexible automation system for sample preparation, analysis, and data evaluation is presented in this article. It is applied for the determination of cholesterol in biliary endoprosthesis using gas chromatography-mass spectrometry (GC-MS). A dual-arm robot performs both transport and active manipulation tasks to ensure human-like operation. This general robotic concept also enables the use of manual laboratory devices and equipment and is thus suitable in areas with a high standardization grade. © 2016 Society for Laboratory Automation and Screening.

  2. Measurement of free thyroxine or free 3,5,3'-triiodothyronine in a liquid sample

    International Nuclear Information System (INIS)

    Hertl, W.; Ward, F.B.; Weetall, H.H.

    1982-01-01

    An immunoassay method is described for the direct measurement of free thyroxine or 3,5,3'-triiodothyronine in a liquid sample in which the thyroxine or 3,5,3'-triiodothyronine is present in both free and combined states. The sample is combined with a labelled thyroxine- or 3,5,3'-triiodothyronine-horseradish peroxidase conjugate which does not significantly interact with thyroxine-binding globulin, thyroxine-binding prealbumin and immobilised antibody which is specific for thyroxine or 3,5,3'-triiodothyronine. After incubation, the solid phase is separated from the liquid phase and the amount of labelled thyroxine- or 3,5,3'-triiodothyronine-horseradish peroxidase conjugate present in either phase is measured by determining the activity of the label. (author)

  3. Collection and preparation of samples for Agency's programme of intercalibration methods and procedures for measurement of environmental radioactivity

    International Nuclear Information System (INIS)

    Patel, B.

    1975-12-01

    In the period of 1971-1975 several samples of marine sediment and organisms were collected from the Bombay Harbour Bay as well as from the vicinity of the Tarapur nuclear power station in order to supply the materials for preparing intercalibration samples for radionuclides measurements. All samples collected were freeze-dried and homogenized prior to the dispatch to the Monaco Laboratory, where final homogenization and the homogeneity tests were carried out. Altogether 2 marine organisms and 3 marine sediments were supplied during this period. The materials supplied were proved to be useful to prepare intercalibration samples for radionuclide measurements in the levels for monitoring operations. Based on these materials several intercalibration exercises were successfully conducted. This work thus formed a basis for bringing the better comparability of radionuclide measurements in marine environmental samples in an international scale

  4. Measurements of linear attenuation coefficients of irregular shaped samples by two media method

    International Nuclear Information System (INIS)

    Singh, Sukhpal; Kumar, Ashok; Thind, Kulwant Singh; Mudahar, Gurmel S.

    2008-01-01

    The linear attenuation coefficient values of regular and irregular shaped flyash materials have been measured without knowing the thickness of a sample using a new technique namely 'two media method'. These values have also been measured with a standard gamma ray transmission method and obtained theoretically with winXCOM computer code. From the comparison it is reported that the two media method has given accurate results of attenuation coefficients of flyash materials

  5. A passive guard for low thermal conductivity measurement of small samples by the hot plate method

    International Nuclear Information System (INIS)

    Jannot, Yves; Godefroy, Justine; Degiovanni, Alain; Grigorova-Moutiers, Veneta

    2017-01-01

    Hot plate methods under steady state conditions are based on a 1D model to estimate the thermal conductivity, using measurements of the temperatures T 0 and T 1 of the two sides of the sample and of the heat flux crossing it. To be consistent with the hypothesis of the 1D heat flux, either a hot plate guarded apparatus is used, or the temperature is measured at the centre of the sample. On one hand the latter method can be used only if the ratio thickness/width of the sample is sufficiently low and on the other hand the guarded hot plate method requires large width samples (typical cross section of 0.6  ×  0.6 m 2 ). That is why both methods cannot be used for low width samples. The method presented in this paper is based on an optimal choice of the temperatures T 0 and T 1 compared to the ambient temperature T a , enabling the estimation of the thermal conductivity with a centered hot plate method, by applying the 1D heat flux model. It will be shown that these optimal values do not depend on the size or on the thermal conductivity of samples (in the range 0.015–0.2 W m −1 K −1 ), but only on T a . The experimental results obtained validate the method for several reference samples for values of the ratio thickness/width up to 0.3, thus enabling the measurement of the thermal conductivity of samples having a small cross-section, down to 0.045  ×  0.045 m 2 . (paper)

  6. Sample Size for Measuring Grammaticality in Preschool Children from Picture-Elicited Language Samples

    Science.gov (United States)

    Eisenberg, Sarita L.; Guo, Ling-Yu

    2015-01-01

    Purpose: The purpose of this study was to investigate whether a shorter language sample elicited with fewer pictures (i.e., 7) would yield a percent grammatical utterances (PGU) score similar to that computed from a longer language sample elicited with 15 pictures for 3-year-old children. Method: Language samples were elicited by asking forty…

  7. Accessing SAFOD data products: Downhole measurements, physical samples and long-term monitoring

    Science.gov (United States)

    Weiland, C.; Zoback, M.; Hickman, S. H.; Ellsworth, W. L.

    2005-12-01

    Many different types of data were collected during SAFOD Phases 1 and 2 (2004-2005) as part of the National Science Foundation's EarthScope program as well as from the SAFOD Pilot Hole, drilled in 2002 and funded by the International Continental Drilling Program (ICDP). Both SAFOD and the SAFOD Pilot Hole are being conducted as a close collaboration between NSF, the U.S. Geological Survey and the ICDP. SAFOD data products include cuttings, core and fluid samples; borehole geophysical measurements; and strain, tilt, and seismic recordings from the multilevel SAFOD borehole monitoring instruments. As with all elements of EarthScope, these data (and samples) are openly available to members of the scientific and educational communities. This paper presents the acquisition, storage and distribution plan for SAFOD data products. Washed and unwashed drill cuttings and mud samples were collected during Phases 1 and 2, along with three spot cores at depths of 1.5, 2.5, and 3.1 km. A total of 52 side-wall cores were also collected in the open-hole interval between 2.5 and 3.1 km depth. The primary coring effort will occur during Phase 3 (2007), when we will continuously core up to four, 250-m-long multilaterals directly within and adjacent to the San Andreas Fault Zone. Drill cuttings, core, and fluid samples from all three Phases of SAFOD drilling are being curated under carefully controlled conditions at the Integrated Ocean Drilling Program (IODP) Gulf Coast Repository in College Station, Texas. Photos of all physical samples and a downloadable sample request form are available on the ICDP website (http://www.icdp-online.de/sites/sanandreas/index/index.html). A suite of downhole geophysical measurements was conducted during the first two Phases of SAFOD drilling, as well as during drilling of the SAFOD Pilot Hole. These data include density, resistivity, porosity, seismic and borehole image logs and are also available via the ICDP website. The SAFOD monitoring program

  8. Relocation work of temporary thermocouples for measuring the vessel cooling system in the safety demonstration test

    International Nuclear Information System (INIS)

    Shimazaki, Yosuke; Shinohara, Masanori; Ono, Masato; Yanagi, Shunki; Tochio, Daisuke; Iigaki, Kazuhiko

    2012-05-01

    It is necessary to confirm that the temperature of water cooling panel of the vessel cooling system (VCS) is controlled under the allowable working temperature during the safety demonstration test because the water cooling panel temperature rises due to stop of cooling water circulation pumps. Therefore, several temporary thermocouples are relocated to the water cooling panel near the stabilizers of RPV and the side cooling panel outlet ring header of VCS in order to observe the temperature change of VCS. The relocated thermocouples can measure the temperature change with starting of the cooling water circulation pumps of VCS. So it is confirmed that the relocated thermocouples can observe the VCS temperature change in the safety demonstration test. (author)

  9. Use of an oscillation technique to measure effective cross-sections of fissionable samples in critical assemblies

    International Nuclear Information System (INIS)

    Tretiakoff, O.; Vidal, R.; Carre, J.C.; Robin, M.

    1964-01-01

    The authors describe the technique used to measure the effective absorption and neutron-yield cross-sections of a fissionable sample. These two values are determined by analysing the signals due to the variation in reactivity (over-all signal) and the local perturbation in the flux (local signal) produced by the oscillating sample. These signals are standardized by means of a set of samples containing quantities of fissionable material ( 235 U) and an absorber, boron, which are well known. The measurements are made for different neutron spectra characterized by lattice parameters which constitute the central zone within which the sample moves. This technique is used to study the effective cross-sections of uranium-plutonium alloys for different heavy-water and graphite lattices in the MINERVE and MARIUS critical assemblies. The same experiments are carried out on fuel samples of different irradiations in order to determine the evolution of effective cross-sections as a function of the spectrum and the irradiations. (authors) [fr

  10. Measurement of regional cerebral blood flow using one-point venous blood sampling and causality model. Evaluation by comparing with conventional continuous arterial blood sampling method

    International Nuclear Information System (INIS)

    Mimura, Hiroaki; Sone, Teruki; Takahashi, Yoshitake

    2008-01-01

    Optimal setting of the input function is essential for the measurement of regional cerebral blood flow (rCBF) based on the microsphere model using N-isopropyl-4-[ 123 I]iodoamphetamine ( 123 I-IMP), and usually the arterial 123 I-IMP concentration (integral value) in the initial 5 min is used for this purpose. We have developed a new convenient method in which 123 I-IMP concentration in arterial blood sample is estimated from that in venous blood sample. Brain perfusion single photon emission computed tomography (SPECT) with 123 I-IMP was performed in 110 cases of central nervous system disorders. The causality was analyzed between the various parameters of SPECT data and the ratio of octanol-extracted arterial radioactivity concentration during the first 5 min (Caoct) to octanol-extracted venous radioactivity concentration at 27 min after intravenous injection of 123 I-IMP (Cvoct). A high correlation was observed between the measured and estimated values of Caoct/Cvoct (r=0.856) when the following five parameters were included in the regression formula: radioactivity concentration in venous blood sampled at 27 min (Cv), Cvoct, Cvoct/Cv, and total brain radioactivity counts that were measured by a four-head gamma camera 5 min and 28 min after 123 I-IMP injection. Furthermore, the rCBF values obtained using the input parameters estimated by this method were also highly correlated with the rCBF values measured using the continuous arterial blood sampling method (r=0.912). These results suggest that this method would serve as the new, convenient and less invasive method of rCBF measurement in clinical setting. (author)

  11. Comparison of accelerator mass spectrometric measurement with liquid scintillation counting measurement for the determination of 14C in environmental samples

    International Nuclear Information System (INIS)

    Yasuike, Kaeko; Yamada, Yoshimune; Amano, Hikaru

    2010-01-01

    The concentrations of organically-bound 14 C in tree-ring cellulose of a Japanese Black Pine grown in Shika-machi (37.0 deg. N, 136.8 deg. E) and those of a Japanese Cedar grown in Kanazawa (36.5 deg. N, 136.7 deg. E), Japan, were analyzed for the ring-years from 1989 to 1998 by the accelerator mass spectrometric measurement. The results were compared with those of the same samples analyzed by the liquid scintillation counting measurement to determine the reliability of liquid scintillation counting measurement. An important result of this study is that the sensitivity and reproducibility of accelerator mass spectrometric measurement was almost equal to that of liquid scintillation counting measurement.

  12. Particle Sampling and Real Time Size Distribution Measurement in H2/O2/TEOS Diffusion Flame

    International Nuclear Information System (INIS)

    Ahn, K.H.; Jung, C.H.; Choi, M.; Lee, J.S.

    2001-01-01

    Growth characteristics of silica particles have been studied experimentally using in situ particle sampling technique from H 2 /O 2 /Tetraethylorthosilicate (TEOS) diffusion flame with carefully devised sampling probe. The particle morphology and the size comparisons are made between the particles sampled by the local thermophoretic method from the inside of the flame and by the electrostatic collector sampling method after the dilution sampling probe. The Transmission Electron Microscope (TEM) image processed data of these two sampling techniques are compared with Scanning Mobility Particle Sizer (SMPS) measurement. TEM image analysis of two sampling methods showed a good agreement with SMPS measurement. The effects of flame conditions and TEOS flow rates on silica particle size distributions are also investigated using the new particle dilution sampling probe. It is found that the particle size distribution characteristics and morphology are mostly governed by the coagulation process and sintering process in the flame. As the flame temperature increases, the effect of coalescence or sintering becomes an important particle growth mechanism which reduces the coagulation process. However, if the flame temperature is not high enough to sinter the aggregated particles then the coagulation process is a dominant particle growth mechanism. In a certain flame condition a secondary particle formation is observed which results in a bimodal particle size distribution

  13. Measurement of carbon-14 in hydrological samples

    International Nuclear Information System (INIS)

    Hussain, S.D.

    1991-11-01

    Thermal neutrons produced by cosmic rays or nuclear weapon tests interact with atmospheric nitrogen resulting in the formation of radiocarbon which, after oxidation into carbon dioxide, follows the natural carbon cycle. The partial pressure of carbon dioxide in the soil is several times that in the atmosphere due to plant root respiration and decay of organic matter. Water absorbs biogenic carbon dioxide while percolating through the unsaturated zone. The carbon content of groundwater is mainly in the form of bicarbonate ions. The extraction of carbon from water sample as barium carbonate is carried out in the field. Benzene is synthesised from the carbonate sample. The activity of radiocarbon in the synthesised benzene is determined by using a liquid scintillation analyzer. Details of sampling procedure, benzene synthesis, counter calibration and treatment of sample data have been given. 7 figs. (author)

  14. Unambiguous range-Doppler LADAR processing using 2 giga-sample-per-second noise waveforms

    International Nuclear Information System (INIS)

    Cole, Z.; Roos, P.A.; Berg, T.; Kaylor, B.; Merkel, K.D.; Babbitt, W.R.; Reibel, R.R.

    2007-01-01

    We demonstrate sub-nanosecond range and unambiguous sub-50-Hz Doppler resolved laser radar (LADAR) measurements using spectral holographic processing in rare-earth ion doped crystals. The demonstration utilizes pseudo-random-noise 2 giga-sample-per-second baseband waveforms modulated onto an optical carrier

  15. Unambiguous range-Doppler LADAR processing using 2 giga-sample-per-second noise waveforms

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Z. [S2 Corporation, 2310 University Way 4-1, Bozeman, MT 59715 (United States)]. E-mail: cole@s2corporation.com; Roos, P.A. [Spectrum Lab, Montana State University, P.O. Box 173510, Bozeman, MT 59717 (United States); Berg, T. [S2 Corporation, 2310 University Way 4-1, Bozeman, MT 59715 (United States); Kaylor, B. [S2 Corporation, 2310 University Way 4-1, Bozeman, MT 59715 (United States); Merkel, K.D. [S2 Corporation, 2310 University Way 4-1, Bozeman, MT 59715 (United States); Babbitt, W.R. [Spectrum Lab, Montana State University, P.O. Box 173510, Bozeman, MT 59717 (United States); Reibel, R.R. [S2 Corporation, 2310 University Way 4-1, Bozeman, MT 59715 (United States)

    2007-11-15

    We demonstrate sub-nanosecond range and unambiguous sub-50-Hz Doppler resolved laser radar (LADAR) measurements using spectral holographic processing in rare-earth ion doped crystals. The demonstration utilizes pseudo-random-noise 2 giga-sample-per-second baseband waveforms modulated onto an optical carrier.

  16. Tested Demonstrations.

    Science.gov (United States)

    Gilbert, George L.

    1983-01-01

    An apparatus is described in which effects of pressure, volume, and temperature changes on a gas can be observed simultaneously. Includes use of the apparatus in demonstrating Boyle's, Gay-Lussac's, and Charles' Laws, attractive forces, Dalton's Law of Partial pressures, and in illustrating measurable vapor pressures of liquids and some solids.…

  17. Can mothers safely prepare labon-gur salt-sugar solution after demonstration in a diarrhoeal hospital?

    DEFF Research Database (Denmark)

    Islam, M A; Kofoed, Poul-Erik; Begum, S

    1992-01-01

    Home-based salt-sugar solution (SSS) prepared with labon (locally produced sea salt) and gur (unrefined brown sugar) has been recommended as a cheap, locally available and a simple tool to prevent and treat diarrhoeal dehydration. Preparation of labon-gur SSS is demonstrated to the patients...... and the attendants at ICDDR, Bangladesh. To evaluate performances, 150 mothers were asked to measure labon and gur by finger pinch and first method and 100 mothers measured half a seer of water to prepare labon-gur SSS, shortly after the demonstration sessions. 4.0% of the samples exceeded the upper safety limit...... this knowledge. Our study suggests that demonstration of home-based SSS in a diarrhoeal hospital may positively affect health education and that health personnel should actively participate in increasing health awareness....

  18. Performance Demonstration Program Plan for Nondestructive Assay of Drummed Wastes for the TRU Waste Characterization Program

    International Nuclear Information System (INIS)

    2005-01-01

    The Performance Demonstration Program (PDP) for Nondestructive Assay (NDA) is a test program designed to yield data on measurement system capability to characterize drummed transuranic (TRU) waste generated throughout the Department of Energy (DOE) complex. The tests are conducted periodically and provide a mechanism for the independent and objective assessment of NDA system performance and capability relative to the radiological characterization objectives and criteria of the Office of Characterization and Transportation (OCT). The primary documents requiring an NDA PDP are the Waste Acceptance Criteria for the Waste Isolation Pilot Plant (WAC), which requires annual characterization facility participation in the PDP, and the Quality Assurance Program Document (QAPD). This NDA PDP implements the general requirements of the QAPD and applicable requirements of the WAC. Measurement facilities must demonstrate acceptable radiological characterization performance through measurement of test samples comprised of pre-specified PDP matrix drum/radioactive source configurations. Measurement facilities are required to analyze the NDA PDP drum samples using the same procedures approved and implemented for routine operational waste characterization activities. The test samples provide an independent means to assess NDA measurement system performance and compliance per criteria delineated in the NDA PDP Plan. General inter-comparison of NDA measurement system performance among DOE measurement facilities and commercial NDA services can also be evaluated using measurement results on similar NDA PDP test samples. A PDP test sample consists of a 55-gallon matrix drum containing a waste matrix type representative of a particular category of the DOE waste inventory and nuclear material standards of known radionuclide and isotopic composition typical of DOE radioactive material. The PDP sample components are made available to participating measurement facilities as designated by the

  19. Including Below Detection Limit Samples in Post Decommissioning Soil Sample Analyses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Hwan; Yim, Man Sung [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    To meet the required standards the site owner has to show that the soil at the facility has been sufficiently cleaned up. To do this one must know the contamination of the soil at the site prior to clean up. This involves sampling that soil to identify the degree of contamination. However there is a technical difficulty in determining how much decontamination should be done. The problem arises when measured samples are below the detection limit. Regulatory guidelines for site reuse after decommissioning are commonly challenged because the majority of the activity in the soil at or below the limit of detection. Using additional statistical analyses of contaminated soil after decommissioning is expected to have the following advantages: a better and more reliable probabilistic exposure assessment, better economics (lower project costs) and improved communication with the public. This research will develop an approach that defines an acceptable method for demonstrating compliance of decommissioned NPP sites and validates that compliance. Soil samples from NPP often contain censored data. Conventional methods for dealing with censored data sets are statistically biased and limited in their usefulness.

  20. Activity measurement of tritium in biological samples by azeotropic distillation liquid scintillation counter

    International Nuclear Information System (INIS)

    Wu Zongmei; Zheng Xiaomin

    1994-01-01

    The authors introduced a method of extracting tissue free water tritium (TFWT) in biological samples by azeotropic distillation with toluene and of measuring its activity by liquid scintillation counter. Measured TFWT recovery ratios of pine needles (fresh), green vegetables, radish, milk, meat, rice are 0.90, 0.95, 0.95, 0.85, 0.53 and 0.90; and the activities of TFWT are 1.8, 3.2, 1.8, 4.0, 3.3 and 2.7 Bq/L, respectively

  1. A tube seepage meter for in situ measurement of seepage rate and groundwater sampling

    Science.gov (United States)

    Solder, John; Gilmore, Troy E.; Genereux, David P.; Solomon, D. Kip

    2016-01-01

    We designed and evaluated a “tube seepage meter” for point measurements of vertical seepage rates (q), collecting groundwater samples, and estimating vertical hydraulic conductivity (K) in streambeds. Laboratory testing in artificial streambeds show that seepage rates from the tube seepage meter agreed well with expected values. Results of field testing of the tube seepage meter in a sandy-bottom stream with a mean seepage rate of about 0.5 m/day agreed well with Darcian estimates (vertical hydraulic conductivity times head gradient) when averaged over multiple measurements. The uncertainties in q and K were evaluated with a Monte Carlo method and are typically 20% and 60%, respectively, for field data, and depend on the magnitude of the hydraulic gradient and the uncertainty in head measurements. The primary advantages of the tube seepage meter are its small footprint, concurrent and colocated assessments of q and K, and that it can also be configured as a self-purging groundwater-sampling device.

  2. The small sample uncertainty aspect in relation to bullwhip effect measurement

    DEFF Research Database (Denmark)

    Nielsen, Erland Hejn

    2009-01-01

    The bullwhip effect as a concept has been known for almost half a century starting with the Forrester effect. The bullwhip effect is observed in many supply chains, and it is generally accepted as a potential malice. Despite of this fact, the bullwhip effect still seems to be first and foremost...... a conceptual phenomenon. This paper intends primarily to investigate why this might be so and thereby investigate the various aspects, possibilities and obstacles that must be taken into account, when considering the potential practical use and measure of the bullwhip effect in order to actually get the supply...... chain under control. This paper will put special emphasis on the unavoidable small-sample uncertainty aspects relating to the measurement or estimation of the bullwhip effect.  ...

  3. Vertical Sampling Scales for Atmospheric Boundary Layer Measurements from Small Unmanned Aircraft Systems (sUAS

    Directory of Open Access Journals (Sweden)

    Benjamin L. Hemingway

    2017-09-01

    Full Text Available The lowest portion of the Earth’s atmosphere, known as the atmospheric boundary layer (ABL, plays an important role in the formation of weather events. Simple meteorological measurements collected from within the ABL, such as temperature, pressure, humidity, and wind velocity, are key to understanding the exchange of energy within this region, but conventional surveillance techniques such as towers, radar, weather balloons, and satellites do not provide adequate spatial and/or temporal coverage for monitoring weather events. Small unmanned aircraft, or aerial, systems (sUAS provide a versatile, dynamic platform for atmospheric sensing that can provide higher spatio-temporal sampling frequencies than available through most satellite sensing methods. They are also able to sense portions of the atmosphere that cannot be measured from ground-based radar, weather stations, or weather balloons and have the potential to fill gaps in atmospheric sampling. However, research on the vertical sampling scales for collecting atmospheric measurements from sUAS and the variabilities of these scales across atmospheric phenomena (e.g., temperature and humidity is needed. The objective of this study is to use variogram analysis, a common geostatistical technique, to determine optimal spatial sampling scales for two atmospheric variables (temperature and relative humidity captured from sUAS. Results show that vertical sampling scales of approximately 3 m for temperature and 1.5–2 m for relative humidity were sufficient to capture the spatial structure of these phenomena under the conditions tested. Future work is needed to model these scales across the entire ABL as well as under variable conditions.

  4. Experimental set-up for electrical resistivity measurements at low temperature in amorphous and crystalline metallic samples

    International Nuclear Information System (INIS)

    Rodriquez Fernandez, J.M.; Lopez Sanchez, R.J.; Gomez-Sal, J.C.

    1986-01-01

    The experimental set-up to measure the thermal variation of the electrical resistivity between 10.5 K and 300 K, has been developed. A four probe A.C. method with a synchronous-detection (lock'in) technique were the idoneous for our proposes. We have designed a new type of pressure sample-holder adopted to the CS-202 type cryostat. The measurements performed on samples already known have allowed us to determine the sensitivity of our experiments, which is Δ ρ/ρ=2x10 -4 . The measurements performed in the new Y 3 Rh 2 Si 2 compound which at 10 K has no magnetic ordering, are also presented. (author)

  5. An approach for measuring the {sup 129}I/{sup 127}I ratio in fish samples

    Energy Technology Data Exchange (ETDEWEB)

    Kusuno, Haruka, E-mail: kusuno@um.u-tokyo.ac.jp [The University Museum, The University of Tokyo, 3-7-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Matsuzaki, Hiroyuki [The University Museum, The University of Tokyo, 3-7-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Nagata, Toshi; Miyairi, Yosuke; Yokoyama, Yusuke [Atmosphere and Ocean Research Institute, The University of Tokyo, 5-1-5, Kashiwanoha, Kashiwa-shi, Chiba 277-8564 (Japan); Ohkouchi, Naohiko [Japan Agency for Marine-Earth Science and Technology, 2-15, Natsushima-cho, Yokosuka-city, Kanagawa 237-0061 (Japan)

    2015-10-15

    The {sup 129}I/{sup 127}I ratio in marine fish samples was measured employing accelerator mass spectrometry. The measurement was successful because of the low experimental background of {sup 129}I. Pyrohydrolysis was applied to extract iodine from fish samples. The experimental background of pyrohydrolysis was checked carefully and evaluated as 10{sup 4}–10{sup 5} atoms {sup 129}I/combustion. The methodology employed in the present study thus required only 0.05–0.2 g of dried fish samples. The methodology was then applied to obtain the {sup 129}I/{sup 127}I ratio of marine fish samples collected from the Western Pacific Ocean as (0.63–1.2) × 10{sup −10}. These values were similar to the ratio for the surface seawater collected at the same station, 0.4 × 10{sup −10}. The {sup 129}I/{sup 127}I ratio of IAEA-414, which was a mix of fish from the Irish Sea and the North Sea, was also measured and determined as 1.82 × 10{sup −7}. Consequently, fish from the Western Pacific Ocean and the North Sea were distinguished by their {sup 129}I/{sup 127}I ratios. The {sup 129}I/{sup 127}I ratio is thus a direct indicator of the area of habitat of fish.

  6. Demonstration of a Rocket-Borne Fiber-Optic Measurement System: The FOVS Experiment of REXUS 15

    Science.gov (United States)

    Rossner, M. R.; Benes, N.; Grubler, T.; Plamauer, S.; Koch, A. W.

    2015-09-01

    As an in-flight experiment in the REXUS 15 programme, the “Fiber-Optic Vibration Sensing Experiment (FOVS)” aimed at the application of so-called fiber Bragg grating sensors. Fiber Bragg gratings are optical gratings inscribed into the core of an optical fiber. They allow for entirely optical measurements of temperatures, mechanical strain and of deduced quantities, such as vibration. Due to their properties - mechanical robustness, high dynamic range etc. - fiber Bragg gratings are particularly suited for withstanding the harsh environmental conditions in a rocket vehicle (very high and very low temperatures, intense vibrations, presence of flammable propellants, etc.). Measurement systems based on fiber Bragg gratings have the potential to contribute to emerging technologies in the commercial launcher segment. Particularly, large sets of measurement data can be acquired with minor mass contribution. This can be applied to techniques such as structural health monitoring, active vibration damping, and actuator monitoring, enabling lighter structures without compromising on reliability. The FOVS experiment demonstrated a fiber-optic vibration and temperature measurement system in an actual flight, and evaluated its benefits compared to conventional electrical sensing in the challenging launcher environment. As a side product, measurements regarding the environmental conditions on the REXUS platform have been acquired.

  7. Optimization of liquid scintillation measurements applied to smears and aqueous samples collected in industrial environments

    Directory of Open Access Journals (Sweden)

    Arnaud Chapon

    Full Text Available Search for low-energy β contaminations in industrial environments requires using Liquid Scintillation Counting. This indirect measurement method supposes a fine control from sampling to measurement itself. Thus, in this paper, we focus on the definition of a measurement method, as generic as possible, for both smears and aqueous samples’ characterization. That includes choice of consumables, sampling methods, optimization of counting parameters and definition of energy windows, using the maximization of a Figure of Merit. Detection limits are then calculated considering these optimized parameters. For this purpose, we used PerkinElmer Tri-Carb counters. Nevertheless, except those relative to some parameters specific to PerkinElmer, most of the results presented here can be extended to other counters. Keywords: Liquid Scintillation Counting (LSC, PerkinElmer, Tri-Carb, Smear, Swipe

  8. Spacecraft Trajectory Estimation Using a Sampled-Data Extended Kalman Filter with Range-Only Measurements

    National Research Council Canada - National Science Library

    Erwin, R. S; Bernstein, Dennis S

    2005-01-01

    .... In this paper we use a sampled-data extended Kalman Filter to estimate the trajectory or a target satellite when only range measurements are available from a constellation or orbiting spacecraft...

  9. Considerations on sample holder design and custom-made non-polarizable electrodes for Spectral Induced Polarization measurements on unsaturated soils

    Science.gov (United States)

    Kaouane, C.; Chouteau, M. C.; Fauchard, C.; Cote, P.

    2014-12-01

    Spectral Induced Polarization (SIP) is a geophysical method sensitive to water content, saturation and grain size distribution. It could be used as an alternative to nuclear probes to assess the compaction of soils in road works. To evaluate the potential of SIP as a practical tool, we designed an experiment for complex conductivity measurements on unsaturated soil samples.Literature presents a large variety of sample holders and designs, each depending on the context. Although we might find some precise description about the sample holder, exact replication is not always possible. Furthermore, the potential measurements are often done using custom-made Ag/AgCl electrodes and very few indications are given on their reliability with time and temperature. Our objective is to perform complex conductivity measurements on soil samples compacted in a PVC cylindrical mould (10 cm-long, 5 cm-diameter) according to geotechnical standards. To expect homogeneous current density, electrical current is transmitted through the sample via chambers filled with agar gel. Agar gel is a good non-polarizable conductor within the frequency range (1 mHz -20kHz). Its electrical properties are slightly known. We measured increasing of agar-agar electrical conductivity in time. We modelled the influence of this variation on the measurement. If the electrodes are located on the sample, it is minimized. Because of the dimensions at stake and the need for simple design, potential electrodes are located outside the sample, hence the gel contributes to the measurements. Since the gel is fairly conductive, we expect to overestimate the sample conductivity. Potential electrodes are non-polarizable Ag/AgCl electrodes. To avoid any leakage, the KCl solution in the electrodes is replaced by saturated KCl-agar gel. These electrodes are low cost and show a low, stable, self-potential (<1mV). In addition, the technique of making electrode can be easily reproduced and storage and maintenance are simple

  10. Gravimetric and volumetric approaches adapted for hydrogen sorption measurements with in situ conditioning on small sorbent samples

    International Nuclear Information System (INIS)

    Poirier, E.; Chahine, R.; Tessier, A.; Bose, T.K.

    2005-01-01

    We present high sensitivity (0 to 1 bar, 295 K) gravimetric and volumetric hydrogen sorption measurement systems adapted for in situ sample conditioning at high temperature and high vacuum. These systems are designed especially for experiments on sorbents available in small masses (mg) and requiring thorough degassing prior to sorption measurements. Uncertainty analysis from instrumental specifications and hydrogen absorption measurements on palladium are presented. The gravimetric and volumetric systems yield cross-checkable results within about 0.05 wt % on samples weighing from (3 to 25) mg. Hydrogen storage capacities of single-walled carbon nanotubes measured at 1 bar and 295 K with both systems are presented

  11. Water stable isotope measurements of Antarctic samples by means of IRMS and WS-CRDS techniques

    Science.gov (United States)

    Michelini, Marzia; Bonazza, Mattia; Braida, Martina; Flora, Onelio; Dreossi, Giuliano; Stenni, Barbara

    2010-05-01

    In the last years in the scientific community there has been an increasing interest for the application of stable isotope techniques to several environmental problems such as drinking water safeguarding, groundwater management, climate change, soils and paleoclimate studies etc. For example, the water stable isotopes, being natural tracers of the hydrological cycle, have been extensively used as tools to characterize regional aquifers and to reconstruct past temperature changes from polar ice cores. Here the need for improvements in analytical techniques: the high request for information calls for technologies that can offer a great quantity of analyses in short times and with low costs. Furthermore, sometimes it is difficult to obtain big amount of samples (as is the case for Antarctic ice cores or interstitial water) preventing the possibility to replicate the analyses. Here, we present oxygen and hydrogen measurements performed on water samples covering a big range of isotopic values (from very negative antarctic precipitation to mid-latitude precipitation values) carried out with both the conventional Isotope Ratio Mass Spectrometry (IRMS) technique and with a new method based on laser absorption techniques, the Wavelenght Scanned Cavity Ringdown Spectroscopy (WS-CRDS). This study is focusing on improving the precision of the measurements carried out with WS-CRDS in order to extensively apply this method to Antarctic ice core paleoclimate studies. The WS-CRDS is a variation of the CRDS developed in 1988 by O'Keef and Deacon. In CRDS a pulse of light goes through a box with high reflective inner surfaces; when there is no sample in the box the light beam doesn't find any obstacle in its path, but the reflectivity of the walls is not perfect so eventually there will be an absorption of the light beam; when the sample is injected in the box there is absorption and the difference between the time of absorption without and with sample is proportional to the quantity

  12. Fewer study participants needed to demonstrate superior antidepressant efficacy when using the Hamilton melancholia subscale (HAM-D6) as outcome measure

    DEFF Research Database (Denmark)

    Østergaard, Søren Dinesen; Bech, Per; Miskowiak, Kamilla Woznica

    2016-01-01

    participants per group would be required to detect a statistically significant difference between EPO and placebo when using the HAM-D6 as outcome measure, whereas the required group size for HAM-D17 would be 146 participants. Limitations The EPO RCT was not originally designed to investigate the research...... placebo-controlled trial (RCT) testing the effect of erythropoietin (EPO) as augmentation therapy in patients with treatment-resistant depression.  Methods We assessed the scalability (Mokken analysis of unidimensionality), responsiveness (item responsiveness analysis) and ability to show drug......-placebo separation (estimation of sample size needed to detect statistically significant difference between EPO and placebo) of the HAM-D6 and the HAM-D17.  Results The HAM-D6 demonstrated higher scalability, higher responsiveness, and better drug-placebo separation compared to the HAM-D17. As a consequence, only 39...

  13. Demonstration testing and evaluation of in situ heating of soil

    International Nuclear Information System (INIS)

    1995-01-01

    This document describes the Quality Assurance Project Plan (QAPP) for IITRI Project C06787 entitled open-quotes Demonstration Testing and Evaluation of In Situ Heating of Soilclose quotes. A work plan for the above mentioned work was previously submitted. This QAPP describes the sampling and analysis of soil core-samples obtained from the K-25 Site (Oak Ridge Gaseous Diffusion Plant) where an in-situ heating and soil decontamination demonstration experiment will be performed. Soil samples taken before and after the experiment will be analyzed for selected volatile organic compounds. The Work Plan mentioned above provides a complete description of the demonstration site, the soil sampling plan, test plan, etc

  14. Thermal neutron absorption cross-section measured on rock samples and brines in the Institute of Nuclear Physics

    International Nuclear Information System (INIS)

    Czubek, J.A.; Drozdowicz, K.; Krynicka-Drozdowicz, E.; Igielski, A.; Woznicka, U.

    1983-01-01

    In consecutive measurements the rock sample (having a fixed and well known shape -in our case it is a sphere or a cylinder and the sample is powdered or liquid) is enveloped in shells of a plexiglass moderator (the neutron parameters of which are known) of variable thickness and irradiated with the pulsed beam of fast neutrons. The die-away rate of thermal neutrons escaping from the whole system is measured. The absorption cross-section of the sample is found as the intersection of the experimental curve (i.e. die -away rate vs thickness of the moderator) with the theoretical one. The theoretical curve is calculated for a given moderator under the assumption of a constant value of the neutron flux inside the sample. This method is independent of the value of the transport cross-section of the sample. It has been checked on artificial materials with a well known elemental composition (liquid or solid) and on the natural brines and rock samples (basalts and dolomite). A special method of calculation of the variance of the measurement has been established. It is based on the multiple computer simulations of all experimental data used in the computation. The one standard deviation of our methods is of the order of 1 up to 3 capture units (1 c.u. = 10 -3 cm -1 ). The volume of the sample needed is of the order of 500ccm. (author)

  15. Bunch length measurements using electro-optical sampling at the SLS linac

    International Nuclear Information System (INIS)

    Winter, A.

    2004-07-01

    A mode-locked titanium-sapphire laser with 15 fs pulse width is used to determine the time profile of the picosecond electron bunches in the Swiss light source linac of the Paul Scherrer Institute, Villigen Switzerland. This was done using the electro-optic effect in Zinc-Telluride crystals and sampling the change induced by coherent transition radiation with the TiSa laser. The development, implementation and results of an analogue synchronisation system to synchronise the repetition rate of the TiSa laser to the radio frequency of the accelerator with a short term stability of 40 fs is presented. The experimental setup of the bunch length measurements is described and results are presented on the coincidence measurements between the laser pulses and the coherent transition radiation pulses generated by the electron bunches. (orig.)

  16. Manual for the Portable Handheld Neutron Counter (PHNC) for Neutron Survey and the Measurement of Plutonium Samples

    International Nuclear Information System (INIS)

    Menlove, H.O.

    2005-01-01

    We have designed a portable neutron detector for passive neutron scanning measurement and coincidence counting of bulk samples of plutonium. The counter will be used for neutron survey applications as well as the measurement of plutonium samples for portable applications. The detector uses advanced design 3 He tubes to increase the efficiency and battery operated shift register electronics. This report describes the hardware, performance, and calibration for the system

  17. The measurement of mass spectrometric peak height ratio of helium isotope in trace samples

    International Nuclear Information System (INIS)

    Sun Mingliang

    1989-01-01

    An experiment study on the measurement of mass spectrometric peak height ratio of helium isotope in the trace gaseous sample is discussed by using the gas purification line designed by the authors and model VG-5400 static-vacuum noble gas mass spectrometer imported and air helium as a standard. The results show that the amount of He and Ne in natural gas sample is 99% after purification. When the amount of He in Mass Spectrometer is more than 4 x 10 -7 cm 3 STP, it's sensitivity remains stable, about 10 -4 A/cm 3 STP He and the precision of 3 He/ 4 He ratio within the following 17 days is 1.32%. The 'ABA' pattern and experiment condition in the measurement of mass spectrometric peak height ratio of He isotope are presented

  18. Measurement and application of purine derivatives: Creatinine ratio in spot urine samples of ruminants

    International Nuclear Information System (INIS)

    Chen, X.B.; Jayasuriya, M.C.N.; Makkar, H.P.S.

    2004-01-01

    The daily excretion of purine derivatives in urine has been used to estimate the supply of microbial protein to ruminant animals. The method provides a simple and non-invasive tool to indicate the nutritional status of farm animals. However due to the need for complete collection of urine the potential application at farm level is restricted. Research conducted under the FAO/IAEA Co-ordinated Research Project has indicated that it is possible to use the purine derivatives:creatinine ratio measured in several spot urine samples collected within a day, as an index of microbial protein supply in a banding system for farm application. Some theoretical and experimental aspects in the measurement of purine derivatives:creatinine ratio in spot urine samples and the possible application of the banding system at the farm level are discussed. (author)

  19. Compressive sensing-based wideband capacitance measurement with a fixed sampling rate lower than the highest exciting frequency

    International Nuclear Information System (INIS)

    Xu, Lijun; Ren, Ying; Sun, Shijie; Cao, Zhang

    2016-01-01

    In this paper, an under-sampling method for wideband capacitance measurement was proposed by using the compressive sensing strategy. As the excitation signal is sparse in the frequency domain, the compressed sampling method that uses a random demodulator was adopted, which could greatly decrease the sampling rate. Besides, four switches were used to replace the multiplier in the random demodulator. As a result, not only the sampling rate can be much smaller than the signal excitation frequency, but also the circuit’s structure is simpler and its power consumption is lower. A hardware prototype was constructed to validate the method. In the prototype, an excitation voltage with a frequency up to 200 kHz was applied to a capacitance-to-voltage converter. The output signal of the converter was randomly modulated by a pseudo-random sequence through four switches. After a low-pass filter, the signal was sampled by an analog-to-digital converter at a sampling rate of 50 kHz, which was three times lower than the highest exciting frequency. The frequency and amplitude of the signal were then reconstructed to obtain the measured capacitance. Both theoretical analysis and experiments were carried out to show the feasibility of the proposed method and to evaluate the performance of the prototype, including its linearity, sensitivity, repeatability, accuracy and stability within a given measurement range. (paper)

  20. Reexamination of basal plane thermal conductivity of suspended graphene samples measured by electro-thermal micro-bridge methods

    Directory of Open Access Journals (Sweden)

    Insun Jo

    2015-05-01

    Full Text Available Thermal transport in suspended graphene samples has been measured in prior works and this work with the use of a suspended electro-thermal micro-bridge method. These measurement results are analyzed here to evaluate and eliminate the errors caused by the extrinsic thermal contact resistance. It is noted that the room-temperature thermal resistance measured in a recent work increases linearly with the suspended length of the single-layer graphene samples synthesized by chemical vapor deposition (CVD, and that such a feature does not reveal the failure of Fourier’s law despite the increase in the reported apparent thermal conductivity with length. The re-analyzed apparent thermal conductivity of a single-layer CVD graphene sample reaches about 1680 ± 180 W m−1 K−1 at room temperature, which is close to the highest value reported for highly oriented pyrolytic graphite. In comparison, the apparent thermal conductivity values measured for two suspended exfoliated bi-layer graphene samples are about 880 ± 60 and 730 ± 60 Wm−1K−1 at room temperature, and approach that of the natural graphite source above room temperature. However, the low-temperature thermal conductivities of these suspended graphene samples are still considerably lower than the graphite values, with the peak thermal conductivities shifted to much higher temperatures. Analysis of the thermal conductivity data reveals that the low temperature behavior is dominated by phonon scattering by polymer residue instead of by the lateral boundary.

  1. Characterization and demonstration results of a SQUID magnetometer system developed for geomagnetic field measurements

    Science.gov (United States)

    Kawai, J.; Miyamoto, M.; Kawabata, M.; Nosé, M.; Haruta, Y.; Uehara, G.

    2017-08-01

    We characterized a low temperature superconducting quantum interference device (SQUID) magnetometer system developed for high-sensitivity geomagnetic field measurement, and demonstrated the detection of weak geomagnetic signals. The SQUID magnetometer system is comprised of three-axis SQUID magnetometers housed in a glass fiber reinforced plastic cryostat, readout electronics with flux locked loop (FLL), a 24-bit data logger with a global positioning system and batteries. The system noise was approximately 0.2 pT √Hz- 1/2 in the 1-50 Hz frequency range. This performance was determined by including the thermal noise and the shielding effect of the copper shield, which covered the SQUID magnetometers to eliminate high-frequency interference. The temperature drift of the system was ˜0.8 pT °C- 1 in an FLL operation. The system operated for a month using 33 l liquid helium. Using this system, we performed the measurements of geomagnetic field in the open-air, far away from the city. The system could detect weak geomagnetic signals such as the Schumann resonance with sixth harmonics, and the ionospheric Alfvén resonance appearing at night, for the north-south and east-west components of the geomagnetic field. We confirm that the system was capable of high-sensitivity measurement of the weak geomagnetic activities.

  2. Split Hopkinson Resonant Bar Test for Sonic-Frequency Acoustic Velocity and Attenuation Measurements of Small, Isotropic Geologic Samples

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, S.

    2011-04-01

    Mechanical properties (seismic velocities and attenuation) of geological materials are often frequency dependent, which necessitates measurements of the properties at frequencies relevant to a problem at hand. Conventional acoustic resonant bar tests allow measuring seismic properties of rocks and sediments at sonic frequencies (several kilohertz) that are close to the frequencies employed for geophysical exploration of oil and gas resources. However, the tests require a long, slender sample, which is often difficult to obtain from the deep subsurface or from weak and fractured geological formations. In this paper, an alternative measurement technique to conventional resonant bar tests is presented. This technique uses only a small, jacketed rock or sediment core sample mediating a pair of long, metal extension bars with attached seismic source and receiver - the same geometry as the split Hopkinson pressure bar test for large-strain, dynamic impact experiments. Because of the length and mass added to the sample, the resonance frequency of the entire system can be lowered significantly, compared to the sample alone. The experiment can be conducted under elevated confining pressures up to tens of MPa and temperatures above 100 C, and concurrently with x-ray CT imaging. The described Split Hopkinson Resonant Bar (SHRB) test is applied in two steps. First, extension and torsion-mode resonance frequencies and attenuation of the entire system are measured. Next, numerical inversions for the complex Young's and shear moduli of the sample are performed. One particularly important step is the correction of the inverted Young's moduli for the effect of sample-rod interfaces. Examples of the application are given for homogeneous, isotropic polymer samples and a natural rock sample.

  3. Measurement of the hyperelastic properties of 44 pathological ex vivo breast tissue samples

    International Nuclear Information System (INIS)

    O'Hagan, Joseph J; Samani, Abbas

    2009-01-01

    The elastic and hyperelastic properties of biological soft tissues have been of interest to the medical community. There are several biomedical applications where parameters characterizing such properties are critical for a reliable clinical outcome. These applications include surgery planning, needle biopsy and brachtherapy where tissue biomechanical modeling is involved. Another important application is interpreting nonlinear elastography images. While there has been considerable research on the measurement of the linear elastic modulus of small tissue samples, little research has been conducted for measuring parameters that characterize the nonlinear elasticity of tissues included in tissue slice specimens. This work presents hyperelastic measurement results of 44 pathological ex vivo breast tissue samples. For each sample, five hyperelastic models have been used, including the Yeoh, N = 2 polynomial, N = 1 Ogden, Arruda-Boyce, and Veronda-Westmann models. Results show that the Yeoh, polynomial and Ogden models are the most accurate in terms of fitting experimental data. The results indicate that almost all of the parameters corresponding to the pathological tissues are between two times to over two orders of magnitude larger than those of normal tissues, with C 11 showing the most significant difference. Furthermore, statistical analysis indicates that C 02 of the Yeoh model, and C 11 and C 20 of the polynomial model have very good potential for cancer classification as they show statistically significant differences for various cancer types, especially for invasive lobular carcinoma. In addition to the potential for use in cancer classification, the presented data are very important for applications such as surgery planning and virtual reality based clinician training systems where accurate nonlinear tissue response modeling is required.

  4. Measurement of the hyperelastic properties of 44 pathological ex vivo breast tissue samples

    Energy Technology Data Exchange (ETDEWEB)

    O' Hagan, Joseph J; Samani, Abbas [Department of Electrical and Computer Engineering, University of Western Ontario, London, ON (Canada)], E-mail: asamani@uwo.ca

    2009-04-21

    The elastic and hyperelastic properties of biological soft tissues have been of interest to the medical community. There are several biomedical applications where parameters characterizing such properties are critical for a reliable clinical outcome. These applications include surgery planning, needle biopsy and brachtherapy where tissue biomechanical modeling is involved. Another important application is interpreting nonlinear elastography images. While there has been considerable research on the measurement of the linear elastic modulus of small tissue samples, little research has been conducted for measuring parameters that characterize the nonlinear elasticity of tissues included in tissue slice specimens. This work presents hyperelastic measurement results of 44 pathological ex vivo breast tissue samples. For each sample, five hyperelastic models have been used, including the Yeoh, N = 2 polynomial, N = 1 Ogden, Arruda-Boyce, and Veronda-Westmann models. Results show that the Yeoh, polynomial and Ogden models are the most accurate in terms of fitting experimental data. The results indicate that almost all of the parameters corresponding to the pathological tissues are between two times to over two orders of magnitude larger than those of normal tissues, with C{sub 11} showing the most significant difference. Furthermore, statistical analysis indicates that C{sub 02} of the Yeoh model, and C{sub 11} and C{sub 20} of the polynomial model have very good potential for cancer classification as they show statistically significant differences for various cancer types, especially for invasive lobular carcinoma. In addition to the potential for use in cancer classification, the presented data are very important for applications such as surgery planning and virtual reality based clinician training systems where accurate nonlinear tissue response modeling is required.

  5. Measurement of the hyperelastic properties of 44 pathological ex vivo breast tissue samples

    Science.gov (United States)

    O'Hagan, Joseph J.; Samani, Abbas

    2009-04-01

    The elastic and hyperelastic properties of biological soft tissues have been of interest to the medical community. There are several biomedical applications where parameters characterizing such properties are critical for a reliable clinical outcome. These applications include surgery planning, needle biopsy and brachtherapy where tissue biomechanical modeling is involved. Another important application is interpreting nonlinear elastography images. While there has been considerable research on the measurement of the linear elastic modulus of small tissue samples, little research has been conducted for measuring parameters that characterize the nonlinear elasticity of tissues included in tissue slice specimens. This work presents hyperelastic measurement results of 44 pathological ex vivo breast tissue samples. For each sample, five hyperelastic models have been used, including the Yeoh, N = 2 polynomial, N = 1 Ogden, Arruda-Boyce, and Veronda-Westmann models. Results show that the Yeoh, polynomial and Ogden models are the most accurate in terms of fitting experimental data. The results indicate that almost all of the parameters corresponding to the pathological tissues are between two times to over two orders of magnitude larger than those of normal tissues, with C11 showing the most significant difference. Furthermore, statistical analysis indicates that C02 of the Yeoh model, and C11 and C20 of the polynomial model have very good potential for cancer classification as they show statistically significant differences for various cancer types, especially for invasive lobular carcinoma. In addition to the potential for use in cancer classification, the presented data are very important for applications such as surgery planning and virtual reality based clinician training systems where accurate nonlinear tissue response modeling is required.

  6. Study the Possibility of measuring Heavy Metals Arising from Gold Mining Sample using 252Cf Neutron Source

    International Nuclear Information System (INIS)

    Soliman, N.F.

    2012-01-01

    Mining activities contribute immensely to trace element pollution .The present work studied the possibility of measuring heavy metals arising from gold mining areas Eastern Desert in Egypt using the isotopic 252 Cf neutron source. 38.5 g of the sample is irradiated in a neutron field of 252 Cf for 36.75 days and 0.3 mg of the sample is irradiated at the Pneumatic Irradiation Rabbit System (PIRS) built in the vertical thermal column of the ET-RR-2 reactor . The induced activities in the samples are measured using two high resolution f ray spectrometry systems (including two calibrated HPGe detectors). The kο standardization neutron activation analysis (kο-NAA) method was used to analyze the sample under investigation. Thermal to epithermal flux ratio fat the two irradiation positions are measured. The obtained results indicated that the values of the suspected heavy metals such as sodium, magnesium, potassium, manganese, arsenic, ruthenium and tantalum were higher than the background values, signifying accumulation of these heavy metals due to gold mining activities .The accuracy and precision of the method has been evaluated

  7. Measurements of light at night (LAN) for a sample of female school teachers

    Science.gov (United States)

    Rea, Mark S.; Brons, Jennifer A.; Figueiro, Mariana G.

    2012-01-01

    Epidemiological studies have shown an association between rotating shiftwork and breast cancer (BC) risk. Recently, light at night (LAN) measured by satellite photometry and by self-reports of bedroom brightness has been shown to be associated with BC risk, irrespective of shiftwork history. Importance has been placed on these associations because retinal light exposures at night can suppress the hormone melatonin and/or disrupt circadian entrainment to the local 24-h light-dark cycle. The present study examined whether it was valid to use satellite photometry and self-reports of brightness to characterize light, as it might stimulate the circadian system and thereby affect BC incidence. Calibrated photometric measurements were made at the bedroom windows and in the bedrooms of a sample of female school teachers, who worked regular dayshifts and lived in a variety of satellite-measured sky brightness categories. The light levels at both locations were usually very low and were independent of the amount of satellite-measured light. Calibrated photometric measurements were also obtained at the corneas of these female school teachers together with calibrated accelerometer measurements for seven consecutive days and evenings. Based upon these personal light exposure and activity measurements, the female teachers who participated in this study did not have disrupted light-dark cycles like those associated with rotating shiftworkers who do exhibit a higher risk for BC. Rather, this sample of female school teachers had 24-h light-dark and activity-rest patterns very much like those experienced by dayshift nurses examined in an earlier study who are not at an elevated risk of BC. No relationship was found between the amount of satellite-measured light levels and the 24-h light-dark patterns these women experienced. It was concluded from the present study that satellite photometry is unrelated to personal light exposures as they might affect melatonin suppression and

  8. Radioactivity measurements of soil samples from Raichur of Karnataka, India

    International Nuclear Information System (INIS)

    Rajesh, S.; Kerur, B.R.; Anilkumar, S.

    2016-01-01

    Radiations present in environment comprise the terrestrial and extraterrestrial radiations. Natural radioactivity measurement, radiation monitoring of the region, dose assessment and interpretation of radiological related parameters are crucial aspects from the public awareness and environmental safety point of view. It is found that values of the radiological parameters obtained for samples in the study area were found within acceptable or permissible limits. The estimated gamma absorbed dose rate was found to be in the range 32 - 162 nGy h -1 . Higher dose rate than that of the normal dose rate were observed in the regions where granitic, granitic gneiss and schist outcrops were prominent area

  9. Monte Carlo simulation of air sampling methods for the measurement of radon decay products.

    Science.gov (United States)

    Sima, Octavian; Luca, Aurelian; Sahagia, Maria

    2017-08-01

    A stochastic model of the processes involved in the measurement of the activity of the 222 Rn decay products was developed. The distributions of the relevant factors, including air sampling and radionuclide collection, are propagated using Monte Carlo simulation to the final distribution of the measurement results. The uncertainties of the 222 Rn decay products concentrations in the air are realistically evaluated. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Using lot quality assurance sampling to assess measurements for growth monitoring in a developing country's primary health care system.

    Science.gov (United States)

    Valadez, J J; Brown, L D; Vargas, W V; Morley, D

    1996-04-01

    Local supervisors used lot quality assurance sampling (LQAS) during routine household visits to assess the technical quality of Costa Rican community-based health workers (CHW): measuring and recording weights of children, interpreting their growth trend and providing nutrition education to mothers. Supervisors sampled 10 households in each of 12 Health Areas (4-8 hours per area). No more than two performance errors were allowed for each CHW. This LQAS decision rule resulted in judgments with a sensitivity and specificity of about 95 percent. Three categories of results are reported: (1) CHW adequately weighed children, calculated ages, identified children requiring nutritional services, and used the growth chart. (2) They needed to improve referral, education, and documentation skills. (3) The lack of system support to regularly provide growth cards, supplementary feeding to identified malnourished children, and other essential materials may have discouraged some CHW resulting in them not applying their skills. Supervisors regularly using LQAS should, by the sixth round of supervision, identify at least 90 percent of inadequately performing CHW. This paper demonstrates the strength of LQAS, namely, to be used easily by low level local health workers to identify poorly functioning components of growth monitoring and promotion.

  11. Hepatic mitochondrial function analysis using needle liver biopsy samples.

    Directory of Open Access Journals (Sweden)

    Michael J J Chu

    Full Text Available BACKGROUNDS AND AIM: Current assessment of pre-operative liver function relies upon biochemical blood tests and histology but these only indirectly measure liver function. Mitochondrial function (MF analysis allows direct measurement of cellular metabolic function and may provide an additional index of hepatic health. Conventional MF analysis requires substantial tissue samples (>100 mg obtained at open surgery. Here we report a method to assess MF using <3 mg of tissue obtained by a Tru-cut® biopsy needle making it suitable for percutaneous application. METHODS: An 18G Bard® Max-core® biopsy instrument was used to collect samples. The optimal Tru-cut® sample weight, stability in ice-cold University of Wisconsin solution, reproducibility and protocol utility was initially evaluated in Wistar rat livers then confirmed in human samples. MF was measured in saponin-permeabilized samples using high-resolution respirometry. RESULTS: The average mass of a single rat and human liver Tru-cut® biopsy was 5.60±0.30 and 5.16±0.15 mg, respectively (mean; standard error of mean. Two milligram of sample was found the lowest feasible mass for the MF assay. Tissue MF declined after 1 hour of cold storage. Six replicate measurements within rats and humans (n = 6 each showed low coefficient of variation (<10% in measurements of State-III respiration, electron transport chain (ETC capacity and respiratory control ratio (RCR. Ischemic rat and human liver samples consistently showed lower State-III respiration, ETC capacity and RCR, compared to normal perfused liver samples. CONCLUSION: Consistent measurement of liver MF and detection of derangement in a disease state was successfully demonstrated using less than half the tissue from a single Tru-cut® biopsy. Using this technique outpatient assessment of liver MF is now feasible, providing a new assay for the evaluation of hepatic function.

  12. Micro-Structure Measurement and Imaging Based on Digital Holography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyeong Suk; Jung, Hyun Chul; Chang, Ho Seob; Akhter, Naseem [Chosun University, Gwangju (Korea, Republic of); Kee, Chang Doo [Chonnam National University, Gwangju (Korea, Republic of)

    2010-06-15

    Advancements in the imaging and computing technology have opened the path to digital holography for non-destructive investigations of technical samples, material property measurement, vibration analysis, flow visualization and stress analysis in aerospace industry which has widened the application of digital holography in the above fields. In this paper, we demonstrate the non-destructive investigation and micro-structure measurement application of digital holography to the small particles and a biological sample. This paper gives a brief description of the digital holograms recorded with this system and illustratively demonstrated

  13. Micro-Structure Measurement and Imaging Based on Digital Holography

    International Nuclear Information System (INIS)

    Kim, Kyeong Suk; Jung, Hyun Chul; Chang, Ho Seob; Akhter, Naseem; Kee, Chang Doo

    2010-01-01

    Advancements in the imaging and computing technology have opened the path to digital holography for non-destructive investigations of technical samples, material property measurement, vibration analysis, flow visualization and stress analysis in aerospace industry which has widened the application of digital holography in the above fields. In this paper, we demonstrate the non-destructive investigation and micro-structure measurement application of digital holography to the small particles and a biological sample. This paper gives a brief description of the digital holograms recorded with this system and illustratively demonstrated

  14. Samples and Sampling Protocols for Scientific Investigations | Joel ...

    African Journals Online (AJOL)

    ... from sampling, through sample preparation, calibration to final measurement and reporting. This paper, therefore offers useful information on practical guidance on sampling protocols in line with best practice and international standards. Keywords: Sampling, sampling protocols, chain of custody, analysis, documentation ...

  15. Natural radioactivity measurements and dosimetric evaluations in soil samples with a high content of NORM

    Science.gov (United States)

    Caridi, F.; Marguccio, S.; Durante, G.; Trozzo, R.; Fullone, F.; Belvedere, A.; D'Agostino, M.; Belmusto, G.

    2017-01-01

    In this article natural radioactivity measurements and dosimetric evaluations in soil samples contaminated by Naturally Occurring Radioactive Materials (NORM) are made, in order to assess any possible radiological hazard for the population and for workers professionally exposed to ionizing radiations. Investigated samples came from the district of Crotone, Calabria region, South of Italy. The natural radioactivity investigation was performed by high-resolution gamma-ray spectrometry. From the measured gamma spectra, activity concentrations were determined for 226Ra , 234-mPa , 224Ra , 228Ac and 40K and compared with their clearance levels for NORM. The total effective dose was calculated for each sample as due to the committed effective dose for inhalation and to the effective dose from external irradiation. The sum of the total effective doses estimated for all investigated samples was compared to the action levels provided by the Italian legislation (D.Lgs.230/95 and subsequent modifications) for the population members (0.3mSv/y) and for professionally exposed workers (1mSv/y). It was found to be less than the limit of no radiological significance (10μSv/y).

  16. Completely non-destructive elemental analysis of bulky samples by PGA

    International Nuclear Information System (INIS)

    Oura, Y.; Nakahara, H.; Sueki, K.; Sato, W.; Tomizawa, T.

    1998-01-01

    A new non-destructive method is proposed for the elemental analysis of bulk samples. It is essentially a combination of PGA and NAA by a single neutron irradiation, and allows determinations of elemental contents of both major and minor constituents relative to that of some reference element. Major elements and some trace elements such as B, Sm, and Gd are mostly determined by the measurement of prompt gamma rays emitted when a bulky sample in its original form, namely, without any reduction of the sample size, is placed in the beam of neutrons guided from a nuclear reactor. Minor elements are then determined by the off-line measurements of gamma rays emitted from the radioactive nuclides produced within the sample by neutron capture reactions. As the radioactivity remaining in the sample becomes negligibly small after a few weeks cooling, the proposed method will be most usefully applied for the elemental analysis of bulky precious samples such as archaeological samples, and arts and crafts. In this presentation, applicability of the method will be demonstrated for porcelain and bronze samples. (author)

  17. An environmental sample chamber for reliable scanning transmission x-ray microscopy measurements under water vapor

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, Stephen T.; Nigge, Pascal; Prakash, Shruti; Gilles, Mary K. [Chemical Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Laskin, Alexander; Wang, Bingbing [William R. Wiley Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352 (United States); Tyliszczak, Tolek [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Leone, Stephen R. [Chemical Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Department of Chemistry and Department of Physics, University of California, Berkeley, California 94720 (United States)

    2013-07-15

    We have designed, fabricated, and tested a compact gas-phase reactor for performing in situ soft x-ray scanning transmission x-ray microscopy (STXM) measurements. The reactor mounts directly to the existing sample holder used in the majority of STXM instruments around the world and installs with minimal instrument reconfiguration. The reactor accommodates many gas atmospheres, but was designed specifically to address the needs of measurements under water vapor. An on-board sensor measures the relative humidity and temperature inside the reactor, minimizing uncertainties associated with measuring these quantities outside the instrument. The reactor reduces x-ray absorption from the process gas by over 85% compared to analogous experiments with the entire STXM instrument filled with process gas. Reduced absorption by the process gas allows data collection at full instrumental resolution, minimizes radiation dose to the sample, and results in much more stable imaging conditions. The reactor is in use at the STXM instruments at beamlines 11.0.2 and 5.3.2.2 at the Advanced Light Source.

  18. Measurement facilities and accuracy limits of sampling digital interferometers. Meresi lehetoesegek es hibaanalizis digitalis mintavetelezoe interferometeren

    Energy Technology Data Exchange (ETDEWEB)

    Czitrovszky, A.; Jani, P.; Szoter, L.

    1990-12-15

    We discuss the measurement facilities of a recently development sampling digital interferometer for machine tool testing. As opposed to conventional interferometers the present device provides possibilities for the digital storage up to 4 kHz of the complete information of the motion so that displacement, velocity, acceleration and power density spectrum measurement can be performed. An estimation is given for the truncation, round-off, jitter and frequency-aliasing sources of error of the reconstructed motion parameters. On the basis of the Shannon sampling theory optimal conditions of measurement parameters are defined for the case when the accuracy of the reconstructed part of motion and vibration is equal to the resolution of the conventional interferometer. 7 refs., 3 figs., 1 tab.

  19. Reducing the sampling periods required in protocols for establishing ammonia emissions from pig fattening buildings using measurements and modelling

    NARCIS (Netherlands)

    Mosquera Losada, J.; Ogink, N.W.M.

    2011-01-01

    Ammonia (NH(3)) emission factors for animal housing systems in the Netherlands are based on measurements using standardised measurement protocols. Both the original Green Label (GL) protocol and the newly developed multi-site sampling protocol are based on year-round sampling periods. The objective

  20. A software for radioactivity measurement of Ra, Th and K in environmental samples

    International Nuclear Information System (INIS)

    Miao Zhengqiang; Bao Min; Chang Yongfu

    2004-01-01

    Radio nuclides of soil, rock, construction material, and almost everything around us. There is growing concern about environmental radioactivity from both scientists and public from an institutional or a common point of view. The regulation and standard on evaluating radioactivity of environmental samples have been issued recently by the authorities. We have developed special purpose Gamma spectra analysis software named ErSpec. The software can effectively process and analyze Gamma spectra measured by a NaI(T1) spectrometry, and can give a relatively precise results of radioactivity of 226 Ra, 232 Th and 40 K in environmental samples. The main functions of ErSpec include, processing and analyzing Gamma spectra, displaying some useful information for users, generating report, managing user's priority, logging user's manipulation, etc. Because environmental samples usually have low radioactivity and have complex measurement conditions, relative method is employed in ErSpec, and Channel-by-Channel Least-Squared Estimation is adopted as spectra analyzing method. The arithmetic make use of information extracted from data of hundreds of channels, then give a rather good result. In ErSpec, by using external call of MatLAB Math Lib in Visual C++, accuracy and speed of calculation and robustness of software are improved distinctly. Object-Oriented Programming Method and ActiveX techniques are also employed in software designing and coding stage. (authors)

  1. Measurement of the carbon 14 activity at natural level in air samples

    International Nuclear Information System (INIS)

    Olivier, A.; Tenailleau, L.; Baron, Y.; Maro, D.

    2004-01-01

    The aim of the study was to measure the carbon 14 activity at natural level in air samples using classical methods of radiochemistry and beta counting. Three different methods have been tested in order to minimise the detection limit. In the three methods, the first step consists in trapping the atmospheric carbon 14 into NaOH (1N) using a bubbling chamber. The atmospheric carbon dioxide reacts with NaOH to form Na 2 CO 3 . In the first method the Na 2 CO 3 solution is mixed with a liquid scintillate and is directly analysed by liquid scintillation counting (LSC). The detection limit is approximately 1 Bq/m 3 of air samples. The second method consists in evaporating the carbonate solution and then counting the solid residue with a proportional gas circulation counter. The detection limit obtained is lower than the first method (0.4 Bq/m 3 of air samples). In the third method, Na 2 CO 3 is precipitated into CaCO 3 in presence of CaCl 2 . CaCO 3 is then analysed by LSC. This method appear to be the most appropriate, the detection limit is 0.05 Bq/m 3 of air samples. (author)

  2. TXRF 'measurements' of concentration distribution below the detection limit

    International Nuclear Information System (INIS)

    Kubala-Kukus, A.; Banas, D.; Braziewicz, J.; Majewska, U.; Mrowczynski, S.; Pajek, M.

    2000-01-01

    We demonstrate that a shape of the concentration distribution of the element in a set of samples, as measured by the TXRF method, can be determined even for the concentrations below the detection limit (DL). This can be done, when the measurements reporting the concentration below DL level are included properly in the analysis of the results. The method developed for such correction is presented and discussed. It is demonstrated that this correction is particularly important when the studied concentrations are close to the DL level of the method, which is a common case for TXRF. In the paper a precision of the developed correction is discussed in details, by using the results of numerical simulations of experiments for different concentration distributions and number of performed measurements. It is demonstrated that the factor, which limits the accuracy of the correction, is the number of measurements, not the correction procedure itself. The applicability and importance of the developed correction is demonstrated for routine TXRF analysis of different types of samples of bio-medical interest. (author)

  3. Stability and reliability of glycated haemoglobin measurements in blood samples stored at -20°C.

    Science.gov (United States)

    Venkataraman, Vijayachandrika; Anjana, Ranjit Mohan; Pradeepa, Rajendra; Deepa, Mohan; Jayashri, Ramamoorthy; Anbalagan, Viknesh Prabu; Akila, Bridgitte; Madhu, Sri Venkata; Lakshmy, Ramakrishnan; Mohan, Viswanathan

    2016-01-01

    To validate the stability of glycated haemoglobin (HbA1c) measurements in blood samples stored at -20°C for up to one month. The study group comprised 142 type 2 diabetic subjects visiting a tertiary centre for diabetes at Chennai city in south India. The HbA1c assay was done on a fasting blood sample using the Bio-Rad Variant machine on Day 0 (day of blood sample collection). Several aliquots were stored at -20°C and the assay was repeated on the 3rd, 7th, 15th, and 30th day after the sample collection. Bland-Altman plots were constructed and variation in the HbA1c levels on the different days was compared with the day 0 level. The median differences between HbA1c levels measured on Day 0 and the 3rd, 7th, 15th, and 30th day after blood collection were 0.0%, 0.2%, 0.3% and 0.5% respectively. Bland-Altman plot analysis showed that the differences between the day '0' and the different time points tend to get larger with time, but these were not clinically significant. HbA1c levels are relatively stable up to 2weeks, if blood samples are stored at -20°C. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. MyOSD 2014: Evaluating Oceanographic Measurements Contributed by Citizen Scientists in Support of Ocean Sampling Day

    Directory of Open Access Journals (Sweden)

    Julia Schnetzer

    2015-11-01

    Full Text Available The first Ocean Sampling Day (OSD took place on June 21, 2014. In a coordinated effort, an internationally distributed group of scientists collected samples from marine surface waters in order to study microbial diversity on a single day with global granularity. Concurrently, citizen scientists enriched the OSD initiative through the MyOSD project, providing additional oceanographic measurements crucial to the contextualization of microbial diversity. Clear protocols, a user-friendly smartphone application, and an online web-form guided citizens in accurate data acquisition, promoting quality submissions to the project’s information system. To evaluate the coverage and quality of MyOSD data submissions, we compared the sea surface temperature measurements acquired through OSD, MyOSD, and automatic in situ systems and satellite measurements. Our results show that the quality of citizen-science measurements was comparable to that of scientific measurements. As 79% of MyOSD measurements were conducted in geographic areas not covered by automatic in situ or satellite measurement, citizen scientists contributed significantly to worldwide oceanographic data gathering. Furthermore, survey results indicate that participation in MyOSD made citizens feel more engaged in ocean issues and may have increased their environmental awareness and ocean literacy.

  5. 40 CFR 761.298 - Decisions based on PCB concentration measurements resulting from sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Decisions based on PCB concentration... Cleanup and On-Site Disposal of Bulk PCB Remediation Waste and Porous Surfaces in Accordance With § 761.61(a)(6) § 761.298 Decisions based on PCB concentration measurements resulting from sampling. (a) For...

  6. Probe sampling measurements and modeling of nitric oxide formation in ethane + air flames

    NARCIS (Netherlands)

    Dyakov, I.V.; Ruyck, de J.; Konnov, A.A.

    2007-01-01

    Burning velocity and probe sampling measurements of the concentrations of O2, CO2, CO and NO in the post-flame zone of ethane + air flames are reported. The heat flux method was used for stabilization of laminar, premixed, non-stretched flames on a perforated plate burner at 1 atm. Axial profiles of

  7. Measurement of radon exhalation rate in various building materials and soil samples

    Science.gov (United States)

    Bala, Pankaj; Kumar, Vinod; Mehra, Rohit

    2017-03-01

    Indoor radon is considered as one of the potential dangerous radioactive elements. Common building materials and soil are the major source of this radon gas in the indoor environment. In the present study, the measurement of radon exhalation rate in the soil and building material samples of Una and Hamirpur districts of Himachal Pradesh has been done with solid state alpha track detectors, LR-115 type-II plastic track detectors. The radon exhalation rate for the soil samples varies from 39.1 to 91.2 mBq kg-1 h-1 with a mean value 59.7 mBq kg-1 h-1. Also the radium concentration of the studied area is found and it varies from 30.6 to 51.9 Bq kg-1 with a mean value 41.6 Bq kg-1. The exhalation rate for the building material samples varies from 40.72 (sandstone) to 81.40 mBq kg-1 h-1 (granite) with a mean value of 59.94 mBq kg-1 h-1.

  8. Spectral BRDF measurements of metallic samples for laser processing applications

    International Nuclear Information System (INIS)

    Vitali, L; Fustinoni, D; Gramazio, P; Niro, A

    2015-01-01

    The spectral bidirectional reflectance distribution function (BRDF) of metals plays an important role in industrial processing involving laser-surface interaction. In particular, in laser metal machining, absorbance is strongly dependent on the radiation incidence angle as well as on finishing and contamination grade of the surface, and in turn it can considerably affect processing results. Very recently, laser radiation is also used to structure metallic surfaces, in order to produce many particular optical effects, ranging from a high level polishing to angular color shifting. Of course, full knowledge of the spectral BRDF of these structured layers makes it possible to infer reflectance or color for any irradiation and viewing angles. In this paper, we present Vis-NIR spectral BRDF measurements of laser-polished metallic, opaque, flat samples commonly employed in such applications. The resulting optical properties seem to be dependent on the atmospheric composition during the polishing process in addition to the roughness. The measurements are carried out with a Perkin Elmer Lambda 950 double-beam spectrophotometer, equipped with the Absolute Reflectance/Transmittance Analyzer (ARTA) motorized goniometer. (paper)

  9. Actual Waste Demonstration of the Nitric-Glycolic Flowsheet for Sludge Batch 9 Qualification

    Energy Technology Data Exchange (ETDEWEB)

    Newell, J. D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Pareizs, J. M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Martino, C. J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Reboul, S. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Coleman, C. J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Edwards, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Johnson, F. C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-09-01

    For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) performs qualification testing to demonstrate that the sludge batch is processable. Testing performed by the Savannah River National Laboratory has shown glycolic acid to be effective in replacing the function of formic acid in the DWPF chemical process. The nitric-glycolic flowsheet reduces mercury, significantly lowers the catalytic generation of hydrogen and ammonia which could allow purge reduction in the Sludge Receipt and Adjustment Tank (SRAT), stabilizes the pH and chemistry in the SRAT and the Slurry Mix Evaporator (SME), allows for effective rheology adjustment, and is favorable with respect to melter flammability. In order to implement the new flowsheet, SRAT and SME cycles, designated SC-18, were performed using a Sludge Batch (SB) 9 slurry blended from SB8 Tank 40H and Tank 51H samples. The SRAT cycle involved adding nitric and glycolic acids to the sludge, refluxing to steam strip mercury, and dewatering to a targeted solids concentration. Data collected during the SRAT cycle included offgas analyses, process temperatures, heat transfer, and pH measurements. The SME cycle demonstrated the addition of glass frit and the replication of six canister decontamination additions. The demonstration concluded with dewatering to a targeted solids concentration. Data collected during the SME cycle included offgas analyses, process temperatures, heat transfer, and pH measurements. Slurry and condensate samples were collected for subsequent analysis

  10. Iodide-assisted total lead measurement and determination of different lead fractions in drinking water samples.

    Science.gov (United States)

    Zhang, Yuanyuan; Ng, Ding-Quan; Lin, Yi-Pin

    2012-07-01

    Lead and its compounds are toxic and can harm human health, especially the intelligence development in children. Accurate measurement of total lead present in drinking water is crucial in determining the extent of lead contamination and human exposure due to drinking water consumption. The USEPA method for total lead measurement (no. 200.8) is often used to analyze lead levels in drinking water. However, in the presence of high concentration of the tetravalent lead corrosion product PbO(2), the USEPA method was not able to fully recover particulate lead due to incomplete dissolution of PbO(2) particles during strong acid digestion. In this study, a new procedure that integrates membrane separation, iodometric PbO(2) measurement, strong acid digestion and ICP-MS measurement was proposed and evaluated for accurate total lead measurement and quantification of different lead fractions including soluble Pb(2+), particulate Pb(II) carbonate and PbO(2) in drinking water samples. The proposed procedure was evaluated using drinking water reconstituted with spiked Pb(2+), spiked particulate Pb(II) carbonate and in situ formed or spiked PbO(2). Recovery tests showed that the proposed procedure and the USEPA method can achieve 93-112% and 86-103% recoveries respectively for samples containing low PbO(2) concentrations (0.018-0.076 mg Pb per L). For samples containing higher concentrations of PbO(2) (0.089-1.316 mg Pb per L), the USEPA method failed to meet the recovery requirement for total lead (85-115%) while the proposed method can achieve satisfactory recoveries (91-111%) and differentiate the soluble Pb(2+), particulate Pb(II) carbonate and PbO(2).

  11. Specific wavelength colorimeter. [for measuring given solute concentration in test sample

    Science.gov (United States)

    Brawner, C. C.; Mcdavid, L. S.; Walsh, J. M. (Inventor)

    1974-01-01

    A self contained, specific wavelength, single beam colorimeter is described for direct spectrophotometric measurement of the concentration of a given solute in a test sample. An electrical circuit employing a photoconductive cell converts the optical output into a linear, directly readable meter output. The colorimeter is simple to operate and is adapted for use in zero gravity conditions. In a specific application, the colorimeter is designed to analyze the concentration of iodine in potable water carried aboard a space vehicle such as the 4B stage of Skylab.

  12. Iohexol plasma clearance measurement in older adults with chronic kidney disease-sampling time matters.

    Science.gov (United States)

    Ebert, Natalie; Loesment, Amina; Martus, Peter; Jakob, Olga; Gaedeke, Jens; Kuhlmann, Martin; Bartel, Jan; Schuchardt, Mirjam; Tölle, Markus; Huang, Tao; van der Giet, Markus; Schaeffner, Elke

    2015-08-01

    Accurate and precise measurement of GFR is important for patients with chronic kidney disease (CKD). Sampling time of exogenous filtration markers may have great impact on measured GFR (mGFR) results, but there is still uncertainty about optimal timing of plasma clearance measurement in patients with advanced CKD, for whom 24-h measurement is recommended. This satellite project of the Berlin Initiative Study evaluates whether 24-h iohexol plasma clearance reveals a clinically relevant difference compared with 5-h measurement in older adults. In 104 participants with a mean age of 79 years and diagnosed CKD, we performed standard GFR measurement over 5 h (mGFR300) using iohexol plasma concentrations at 120, 180, 240 and 300 min after injection. With an additional sample at 1440 min, we assessed 24-h GFR measurement (mGFR1440). Study design was cross-sectional. Calculation of mGFR was conducted with a one compartment model using the Brochner-Mortensen equation to calculate the fast component. mGFR values were compared with estimated GFR values (MDRD, CKD-EPI, BIS1, Revised Lund-Malmö and Cockcroft-Gault). In all 104 subjects, mGFR1440 was lower than mGFR300 (23 ± 8 versus 29 ± 9 mL/min/1.73 m(2), mean ± SD; P clearance up to 5 h leads to a clinically relevant overestimation of GFR compared with 24-h measurement. In clinical care, this effect should be bore in mind especially for patients with considerably reduced GFR levels. A new correction formula has been developed to predict mGFR1440 from mGFR300. For accurate GFR estimates in elderly CKD patients, we recommend the Revised Lund Malmö equation. © The Author 2015. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  13. 40 CFR 761.316 - Interpreting PCB concentration measurements resulting from this sampling scheme.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Interpreting PCB concentration... § 761.79(b)(3) § 761.316 Interpreting PCB concentration measurements resulting from this sampling... composite is 20 µg/100 cm2, then the entire 9.5 square meters has a PCB surface concentration of 20 µg/100...

  14. UV Absorption Measurements of Nitric Oxide Compared to Probe Sampling Data for Measurements in a Turbine Engine Exhaust at Simulated Altitude Conditions

    National Research Council Canada - National Science Library

    Howard, R

    1997-01-01

    Nitric oxide measurements were conducted in the exhaust of a turbofan engine at simulated altitude conditions in a ground-level test cell using both optical nonintrusive and conventional gas sampling techniques...

  15. EDRXF measurements of heavy elements in soil samples from some potentially polluted sites in zambia

    International Nuclear Information System (INIS)

    Hayumbu, P.; Phiri, L.K.; Mambo, A.; Sokotela, S.B.

    2001-01-01

    A survey of heavy element levels in top soils collected around four industrial plants and along four highway stretches demonstrated that there was significant pollution only around an abandoned Pb/Zn mine. Sample collection in a rectangular grid encompassing each source sought to depict the spatial extent of pollution. Ascertaining levels of heavy elements in potentially polluted soils in urban areas of Zambia and along major highways was deemed desirable because it is common practice to grow maize and vegetables in lots adjacent to accessible industrial sites and highways. Pb is a heavy element of interest for all sampled sites whose distribution at the abandoned mine ranged from 13 to 2028 ppm

  16. Residential Energy Efficiency Demonstration: Hawaii and Guam Energy Improvement Technology Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    Earle, L. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sparn, B. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Rutter, A. [Sustainability Solutions LLC (Guam); Briggs, D. [Naval Base Guam, Santa Rita (Guam)

    2014-03-01

    In order to meet its energy goals, the Department of Defense (DOD) has partnered with the Department of Energy (DOE) to rapidly demonstrate and deploy cost-effective renewable energy and energy-efficiency technologies. The scope of this project was to demonstrate tools and technologies to reduce energy use in military housing, with particular emphasis on measuring and reducing loads related to consumer electronics (commonly referred to as 'plug loads'), hot water, and whole-house cooling.

  17. Alpha Matting with KL-Divergence Based Sparse Sampling.

    Science.gov (United States)

    Karacan, Levent; Erdem, Aykut; Erdem, Erkut

    2017-06-22

    In this paper, we present a new sampling-based alpha matting approach for the accurate estimation of foreground and background layers of an image. Previous sampling-based methods typically rely on certain heuristics in collecting representative samples from known regions, and thus their performance deteriorates if the underlying assumptions are not satisfied. To alleviate this, we take an entirely new approach and formulate sampling as a sparse subset selection problem where we propose to pick a small set of candidate samples that best explains the unknown pixels. Moreover, we describe a new dissimilarity measure for comparing two samples which is based on KLdivergence between the distributions of features extracted in the vicinity of the samples. The proposed framework is general and could be easily extended to video matting by additionally taking temporal information into account in the sampling process. Evaluation on standard benchmark datasets for image and video matting demonstrates that our approach provides more accurate results compared to the state-of-the-art methods.

  18. Direct measurements of sample heating by a laser-induced air plasma in pre-ablation spark dual-pulse laser-induced breakdown spectroscopy (LIBS).

    Science.gov (United States)

    Register, Janna; Scaffidi, Jonathan; Angel, S Michael

    2012-08-01

    Direct measurements of temperature changes were made using small thermocouples (TC), placed near a laser-induced air plasma. Temperature changes up to ~500 °C were observed. From the measured temperature changes, estimates were made of the amount of heat absorbed per unit area. This allowed calculations to be made of the surface temperature, as a function of time, of a sample heated by the air plasma that is generated during orthogonal pre-ablation spark dual-pulse (DP) LIBS measurements. In separate experiments, single-pulse (SP) LIBS emission and sample ablation rate measurements were performed on nickel at sample temperatures ranging from room temperature to the maximum surface temperature that was calculated using the TC measurement results (500 °C). A small, but real sample temperature-dependent increase in both SP LIBS emission and the rate of sample ablation was found for nickel samples heated up to 500 °C. Comparison of DP LIBS emission enhancement values for bulk nickel samples at room temperature versus the enhanced SP LIBS emission and sample ablation rates observed as a function of increasing sample temperature suggests that sample heating by the laser-induced air plasma plays only a minor role in DP LIBS emission enhancement.

  19. Determination of air-loop volume and radon partition coefficient for measuring radon in water sample.

    Science.gov (United States)

    Lee, Kil Yong; Burnett, William C

    A simple method for the direct determination of the air-loop volume in a RAD7 system as well as the radon partition coefficient was developed allowing for an accurate measurement of the radon activity in any type of water. The air-loop volume may be measured directly using an external radon source and an empty bottle with a precisely measured volume. The partition coefficient and activity of radon in the water sample may then be determined via the RAD7 using the determined air-loop volume. Activity ratios instead of absolute activities were used to measure the air-loop volume and the radon partition coefficient. In order to verify this approach, we measured the radon partition coefficient in deionized water in the temperature range of 10-30 °C and compared the values to those calculated from the well-known Weigel equation. The results were within 5 % variance throughout the temperature range. We also applied the approach for measurement of the radon partition coefficient in synthetic saline water (0-75 ppt salinity) as well as tap water. The radon activity of the tap water sample was determined by this method as well as the standard RAD-H 2 O and BigBottle RAD-H 2 O. The results have shown good agreement between this method and the standard methods.

  20. Determination of air-loop volume and radon partition coefficient for measuring radon in water sample

    International Nuclear Information System (INIS)

    Kil Yong Lee; Burnett, W.C.

    2013-01-01

    A simple method for the direct determination of the air-loop volume in a RAD7 system as well as the radon partition coefficient was developed allowing for an accurate measurement of the radon activity in any type of water. The air-loop volume may be measured directly using an external radon source and an empty bottle with a precisely measured volume. The partition coefficient and activity of radon in the water sample may then be determined via the RAD7 using the determined air-loop volume. Activity ratios instead of absolute activities were used to measure the air-loop volume and the radon partition coefficient. In order to verify this approach, we measured the radon partition coefficient in deionized water in the temperature range of 10-30 deg C and compared the values to those calculated from the well-known Weigel equation. The results were within 5 % variance throughout the temperature range. We also applied the approach for measurement of the radon partition coefficient in synthetic saline water (0-75 ppt salinity) as well as tap water. The radon activity of the tap water sample was determined by this method as well as the standard RAD-H 2 O and BigBottle RAD-H 2 O. The results have shown good agreement between this method and the standard methods. (author)