WorldWideScience

Sample records for sampling locations results

  1. Results of Macroinvertebrate Sampling Conducted at 33 SRS Stream Locations, July--August 1993

    Energy Technology Data Exchange (ETDEWEB)

    Specht, W.L.

    1994-12-01

    In order to assess the health of the macroinvertebrate communities of SRS streams, the macroinvertebrate communities at 30 stream locations on SRS were sampled during the summer of 1993, using Hester-Dendy multiplate samplers. In addition, three off-site locations in the Upper Three Runs drainage were sampled in order to assess the potential for impact from off-site activities. In interpreting the data, it is important to recognize that these data were from a single set of collections. Macroinvertebrate communities often undergo considerable temporal variation, and are also greatly influenced by such factors as water depth, water velocity, and available habitat. These stations were selected with the intent of developing an on-going sampling program at a smaller number of stations, with the selection of the stations to be based largely upon the results of this preliminary sampling program. When stations within a given stream showed similar results, fewer stations would be sampled in the future. Similarly, if a stream appeared to be perturbed, additional stations or chemical analyses might be added so that the source of the perturbation could be identified. In general, unperturbed streams will contain more taxa than perturbed streams, and the distribution of taxa among orders or families will differ. Some groups of macroinvertebrates, such as Ephemeroptera (mayflies), Plecoptera (stoneflies) and Trichoptera (caddisflies), which are collectively called EPT taxa, are considered to be relatively sensitive to most kinds of stream perturbation; therefore a reduced number of EPT taxa generally indicates that the stream has been subject to chemical or physical stressors. In coastal plain streams, EPT taxa are generally less dominant than in streams with rocky substrates, while Chironomidae (midges) are more abundant. (Abstract Truncated)

  2. Determination of geostatistically representative sampling locations in Porsuk Dam Reservoir (Turkey)

    Science.gov (United States)

    Aksoy, A.; Yenilmez, F.; Duzgun, S.

    2013-12-01

    Several factors such as wind action, bathymetry and shape of a lake/reservoir, inflows, outflows, point and diffuse pollution sources result in spatial and temporal variations in water quality of lakes and reservoirs. The guides by the United Nations Environment Programme and the World Health Organization to design and implement water quality monitoring programs suggest that even a single monitoring station near the center or at the deepest part of a lake will be sufficient to observe long-term trends if there is good horizontal mixing. In stratified water bodies, several samples can be required. According to the guide of sampling and analysis under the Turkish Water Pollution Control Regulation, a minimum of five sampling locations should be employed to characterize the water quality in a reservoir or a lake. The European Union Water Framework Directive (2000/60/EC) states to select a sufficient number of monitoring sites to assess the magnitude and impact of point and diffuse sources and hydromorphological pressures in designing a monitoring program. Although existing regulations and guidelines include frameworks for the determination of sampling locations in surface waters, most of them do not specify a procedure in establishment of monitoring aims with representative sampling locations in lakes and reservoirs. In this study, geostatistical tools are used to determine the representative sampling locations in the Porsuk Dam Reservoir (PDR). Kernel density estimation and kriging were used in combination to select the representative sampling locations. Dissolved oxygen and specific conductivity were measured at 81 points. Sixteen of them were used for validation. In selection of the representative sampling locations, care was given to keep similar spatial structure in distributions of measured parameters. A procedure was proposed for that purpose. Results indicated that spatial structure was lost under 30 sampling points. This was as a result of varying water

  3. Direct visualization of solute locations in laboratory ice samples

    Directory of Open Access Journals (Sweden)

    T. Hullar

    2016-09-01

    Full Text Available Many important chemical reactions occur in polar snow, where solutes may be present in several reservoirs, including at the air–ice interface and in liquid-like regions within the ice matrix. Some recent laboratory studies suggest chemical reaction rates may differ in these two reservoirs. While investigations have examined where solutes are found in natural snow and ice, few studies have examined either solute locations in laboratory samples or the possible factors controlling solute segregation. To address this, we used micro-computed tomography (microCT to examine solute locations in ice samples prepared from either aqueous cesium chloride (CsCl or rose bengal solutions that were frozen using several different methods. Samples frozen in a laboratory freezer had the largest liquid-like inclusions and air bubbles, while samples frozen in a custom freeze chamber had somewhat smaller air bubbles and inclusions; in contrast, samples frozen in liquid nitrogen showed much smaller concentrated inclusions and air bubbles, only slightly larger than the resolution limit of our images (∼ 2 µm. Freezing solutions in plastic vs. glass vials had significant impacts on the sample structure, perhaps because the poor heat conductivity of plastic vials changes how heat is removed from the sample as it cools. Similarly, the choice of solute had a significant impact on sample structure, with rose bengal solutions yielding smaller inclusions and air bubbles compared to CsCl solutions frozen using the same method. Additional experiments using higher-resolution imaging of an ice sample show that CsCl moves in a thermal gradient, supporting the idea that the solutes in ice are present in mobile liquid-like regions. Our work shows that the structure of laboratory ice samples, including the location of solutes, is sensitive to the freezing method, sample container, and solute characteristics, requiring careful experimental design and interpretation of results.

  4. Additional Samples: Where They Should Be Located

    International Nuclear Information System (INIS)

    Pilger, G. G.; Costa, J. F. C. L.; Koppe, J. C.

    2001-01-01

    Information for mine planning requires to be close spaced, if compared to the grid used for exploration and resource assessment. The additional samples collected during quasimining usually are located in the same pattern of the original diamond drillholes net but closer spaced. This procedure is not the best in mathematical sense for selecting a location. The impact of an additional information to reduce the uncertainty about the parameter been modeled is not the same everywhere within the deposit. Some locations are more sensitive in reducing the local and global uncertainty than others. This study introduces a methodology to select additional sample locations based on stochastic simulation. The procedure takes into account data variability and their spatial location. Multiple equally probable models representing a geological attribute are generated via geostatistical simulation. These models share basically the same histogram and the same variogram obtained from the original data set. At each block belonging to the model a value is obtained from the n simulations and their combination allows one to access local variability. Variability is measured using an uncertainty index proposed. This index was used to map zones of high variability. A value extracted from a given simulation is added to the original data set from a zone identified as erratic in the previous maps. The process of adding samples and simulation is repeated and the benefit of the additional sample is evaluated. The benefit in terms of uncertainty reduction is measure locally and globally. The procedure showed to be robust and theoretically sound, mapping zones where the additional information is most beneficial. A case study in a coal mine using coal seam thickness illustrates the method

  5. Infill sampling criteria to locate extremes

    CSIR Research Space (South Africa)

    Watson, AG

    1995-07-01

    Full Text Available Three problem-dependent meanings for engineering ''extremes'' are motivated, established, and translated into formal geostatistical (model-based) criteria for designing infill sample networks. (I) Locate an area within the domain of interest where a...

  6. Optimizing Soil Moisture Sampling Locations for Validation Networks for SMAP

    Science.gov (United States)

    Roshani, E.; Berg, A. A.; Lindsay, J.

    2013-12-01

    Soil Moisture Active Passive satellite (SMAP) is scheduled for launch on Oct 2014. Global efforts are underway for establishment of soil moisture monitoring networks for both the pre- and post-launch validation and calibration of the SMAP products. In 2012 the SMAP Validation Experiment, SMAPVEX12, took place near Carman Manitoba, Canada where nearly 60 fields were sampled continuously over a 6 week period for soil moisture and several other parameters simultaneous to remotely sensed images of the sampling region. The locations of these sampling sites were mainly selected on the basis of accessibility, soil texture, and vegetation cover. Although these criteria are necessary to consider during sampling site selection, they do not guarantee optimal site placement to provide the most efficient representation of the studied area. In this analysis a method for optimization of sampling locations is presented which combines the state-of-art multi-objective optimization engine (non-dominated sorting genetic algorithm, NSGA-II), with the kriging interpolation technique to minimize the number of sampling sites while simultaneously minimizing the differences between the soil moisture map resulted from the kriging interpolation and soil moisture map from radar imaging. The algorithm is implemented in Whitebox Geospatial Analysis Tools, which is a multi-platform open-source GIS. The optimization framework is subject to the following three constraints:. A) sampling sites should be accessible to the crew on the ground, B) the number of sites located in a specific soil texture should be greater than or equal to a minimum value, and finally C) the number of sampling sites with a specific vegetation cover should be greater than or equal to a minimum constraint. The first constraint is implemented into the proposed model to keep the practicality of the approach. The second and third constraints are considered to guarantee that the collected samples from each soil texture categories

  7. An assessment of air sampling location for stack monitoring in nuclear facility

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Bok [University of Science and Technology, Daejeon (Korea, Republic of); Kim, Tae Hyoung; Lee, Jong Il; Kim, Bong Hwan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-06-15

    In this study, air sampling locations in the stack of the Advanced Fuel Science Building (AFSB) at the Korea Atomic Energy Research Institute (KAERI) were assessed according to the ANSI/HPS N13.1-1999 specification. The velocity profile, flow angle and 10 μm aerosol particle profile at the cross-section as functions of stack height L and stack diameter D (L/D) were assessed according to the sampling location criteria using COMSOL. The criteria for the velocity profile were found to be met at 5 L/D or more for the height, and the criteria for the average flow angle were met at all locations through this assessment. The criteria for the particle profile were met at 5 L/D and 9 L/D. However, the particle profile at the cross-section of each sampling location was found to be non-uniform. In order to establish uniformity of the particle profile, a static mixer and a perimeter ring were modeled, after which the degrees of effectiveness of these components were compared. Modeling using the static mixer indicated that the sampling locations that met the criteria for the particle profile were 5-10 L/D. When modeling using the perimeter ring, the sampling locations that met the criteria for particle profile were 5 L/D and 7-10 L/D. The criteria for the velocity profile and the average flow angle were also met at the sampling locations that met the criteria for the particle profile. The methodologies used in this study can also be applied during assessments of air sampling locations when monitoring stacks at new nuclear facilities as well as existing nuclear facilities.

  8. ENVIRONMENTAL SAMPLING USING LOCATION SPECIFIC AIR MONITORING IN BULK HANDLING FACILITIES

    Energy Technology Data Exchange (ETDEWEB)

    Sexton, L.; Hanks, D.; Degange, J.; Brant, H.; Hall, G.; Cable-Dunlap, P.; Anderson, B.

    2011-06-07

    Since the introduction of safeguards strengthening measures approved by the International Atomic Energy Agency (IAEA) Board of Governors (1992-1997), international nuclear safeguards inspectors have been able to utilize environmental sampling (ES) (e.g. deposited particulates, air, water, vegetation, sediments, soil and biota) in their safeguarding approaches at bulk uranium/plutonium handling facilities. Enhancements of environmental sampling techniques used by the IAEA in drawing conclusions concerning the absence of undeclared nuclear materials or activities will soon be able to take advantage of a recent step change improvement in the gathering and analysis of air samples at these facilities. Location specific air monitoring feasibility tests have been performed with excellent results in determining attribute and isotopic composition of chemical elements present in an actual test-bed sample. Isotopic analysis of collected particles from an Aerosol Contaminant Extractor (ACE) collection, was performed with the standard bulk sampling protocol used throughout the IAEA network of analytical laboratories (NWAL). The results yielded bulk isotopic values expected for the operations. Advanced designs of air monitoring instruments such as the ACE may be used in gas centrifuge enrichment plants (GCEP) to detect the production of highly enriched uranium (HEU) or enrichments not declared by a State. Researchers at Savannah River National Laboratory in collaboration with Oak Ridge National Laboratory are developing the next generation of ES equipment for air grab and constant samples that could become an important addition to the international nuclear safeguards inspector's toolkit. Location specific air monitoring to be used to establish a baseline environmental signature of a particular facility employed for comparison of consistencies in declared operations will be described in this paper. Implementation of air monitoring will be contrasted against the use of smear

  9. Evaluation of the role of location and distance in recruitment in respondent-driven sampling

    Directory of Open Access Journals (Sweden)

    Hayes Richard J

    2011-10-01

    Full Text Available Abstract Background Respondent-driven sampling(RDS is an increasingly widely used variant of a link tracing design for recruiting hidden populations. The role of the spatial distribution of the target population has not been robustly examined for RDS. We examine patterns of recruitment by location, and how they may have biased an RDS study findings. Methods Total-population data were available on a range of characteristics on a population of 2402 male household-heads from an open cohort of 25 villages in rural Uganda. The locations of households were known a-priori. An RDS survey was carried out in this population, employing current RDS methods of sampling and statistical inference. Results There was little heterogeneity in the population by location. Data suggested more distant contacts were less likely to be reported, and therefore recruited, but if reported more distant contacts were as likely as closer contacts to be recruited. There was no evidence that closer proximity to a village meeting place was associated with probability of being recruited, however it was associated with a higher probability of recruiting a larger number of recruits. People living closer to an interview site were more likely to be recruited. Conclusions Household location affected the overall probability of recruitment, and the probability of recruitment by a specific recruiter. Patterns of recruitment do not appear to have greatly biased estimates in this study. The observed patterns could result in bias in more geographically heterogeneous populations. Care is required in RDS studies when choosing the network size question and interview site location(s.

  10. Estimation of uranium in drinking water samples collected from different locations across Tarapur, India

    International Nuclear Information System (INIS)

    Dusane, C.B.; Maity, Sukanta; Sahu, S.K.; Pandit, G.G.

    2015-01-01

    In this study, drinking water samples were collected from different locations across Tarapur, India for screening uranium contents. Uranium concentrations were determined by differential pulse adsorptive stripping voltammetry (DPASV). Uranium concentration in water samples varied in a wide range from 0.6-7.9 μg L -1 . Results were compared with the international water quality guidelines World Health Organization (WHO, 2011) and were found within the permissible limit. Results were also compared with the safe limit values for drinking water recommended by national organization like Atomic Energy Regulatory Board (AERB). (author)

  11. Statistical Analysis Of Tank 19F Floor Sample Results

    International Nuclear Information System (INIS)

    Harris, S.

    2010-01-01

    Representative sampling has been completed for characterization of the residual material on the floor of Tank 19F as per the statistical sampling plan developed by Harris and Shine. Samples from eight locations have been obtained from the tank floor and two of the samples were archived as a contingency. Six samples, referred to in this report as the current scrape samples, have been submitted to and analyzed by SRNL. This report contains the statistical analysis of the floor sample analytical results to determine if further data are needed to reduce uncertainty. Included are comparisons with the prior Mantis samples results to determine if they can be pooled with the current scrape samples to estimate the upper 95% confidence limits (UCL95%) for concentration. Statistical analysis revealed that the Mantis and current scrape sample results are not compatible. Therefore, the Mantis sample results were not used to support the quantification of analytes in the residual material. Significant spatial variability among the current scrape sample results was not found. Constituent concentrations were similar between the North and South hemispheres as well as between the inner and outer regions of the tank floor. The current scrape sample results from all six samples fall within their 3-sigma limits. In view of the results from numerous statistical tests, the data were pooled from all six current scrape samples. As such, an adequate sample size was provided for quantification of the residual material on the floor of Tank 19F. The uncertainty is quantified in this report by an UCL95% on each analyte concentration. The uncertainty in analyte concentration was calculated as a function of the number of samples, the average, and the standard deviation of the analytical results. The UCL95% was based entirely on the six current scrape sample results (each averaged across three analytical determinations).

  12. A multi-dimensional sampling method for locating small scatterers

    International Nuclear Information System (INIS)

    Song, Rencheng; Zhong, Yu; Chen, Xudong

    2012-01-01

    A multiple signal classification (MUSIC)-like multi-dimensional sampling method (MDSM) is introduced to locate small three-dimensional scatterers using electromagnetic waves. The indicator is built with the most stable part of signal subspace of the multi-static response matrix on a set of combinatorial sampling nodes inside the domain of interest. It has two main advantages compared to the conventional MUSIC methods. First, the MDSM is more robust against noise. Second, it can work with a single incidence even for multi-scatterers. Numerical simulations are presented to show the good performance of the proposed method. (paper)

  13. STATISTICAL ANALYSIS OF TANK 18F FLOOR SAMPLE RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    Harris, S.

    2010-09-02

    Representative sampling has been completed for characterization of the residual material on the floor of Tank 18F as per the statistical sampling plan developed by Shine [1]. Samples from eight locations have been obtained from the tank floor and two of the samples were archived as a contingency. Six samples, referred to in this report as the current scrape samples, have been submitted to and analyzed by SRNL [2]. This report contains the statistical analysis of the floor sample analytical results to determine if further data are needed to reduce uncertainty. Included are comparisons with the prior Mantis samples results [3] to determine if they can be pooled with the current scrape samples to estimate the upper 95% confidence limits (UCL{sub 95%}) for concentration. Statistical analysis revealed that the Mantis and current scrape sample results are not compatible. Therefore, the Mantis sample results were not used to support the quantification of analytes in the residual material. Significant spatial variability among the current sample results was not found. Constituent concentrations were similar between the North and South hemispheres as well as between the inner and outer regions of the tank floor. The current scrape sample results from all six samples fall within their 3-sigma limits. In view of the results from numerous statistical tests, the data were pooled from all six current scrape samples. As such, an adequate sample size was provided for quantification of the residual material on the floor of Tank 18F. The uncertainty is quantified in this report by an upper 95% confidence limit (UCL{sub 95%}) on each analyte concentration. The uncertainty in analyte concentration was calculated as a function of the number of samples, the average, and the standard deviation of the analytical results. The UCL{sub 95%} was based entirely on the six current scrape sample results (each averaged across three analytical determinations).

  14. Water Quality Sampling Locations Along the Shoreline of the Columbia River, Hanford Site, Washington

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, Robert E.; Patton, Gregory W.

    2009-12-14

    As environmental monitoring evolved on the Hanford Site, several different conventions were used to name or describe location information for various sampling sites along the Hanford Reach of the Columbia River. These methods range from handwritten descriptions in field notebooks to the use of modern electronic surveying equipment, such as Global Positioning System receivers. These diverse methods resulted in inconsistent archiving of analytical results in various electronic databases and published reports because of multiple names being used for the same site and inaccurate position data. This document provides listings of sampling sites that are associated with groundwater and river water sampling. The report identifies names and locations for sites associated with sampling: (a) near-river groundwater using aquifer sampling tubes; (b) riverbank springs and springs areas; (c) pore water collected from riverbed sediment; and (d) Columbia River water. Included in the listings are historical names used for a particular site and the best available geographic coordinates for the site, as of 2009. In an effort to create more consistency in the descriptive names used for water quality sampling sites, a naming convention is proposed in this document. The convention assumes that a unique identifier is assigned to each site that is monitored and that this identifier serves electronic database management requirements. The descriptive name is assigned for the convenience of the subsequent data user. As the historical database is used more intensively, this document may be revised as a consequence of discovering potential errors and also because of a need to gain consensus on the proposed naming convention for some water quality monitoring sites.

  15. Systematic sampling with errors in sample locations

    DEFF Research Database (Denmark)

    Ziegel, Johanna; Baddeley, Adrian; Dorph-Petersen, Karl-Anton

    2010-01-01

    analysis using point process methods. We then analyze three different models for the error process, calculate exact expressions for the variances, and derive asymptotic variances. Errors in the placement of sample points can lead to substantial inflation of the variance, dampening of zitterbewegung......Systematic sampling of points in continuous space is widely used in microscopy and spatial surveys. Classical theory provides asymptotic expressions for the variance of estimators based on systematic sampling as the grid spacing decreases. However, the classical theory assumes that the sample grid...... is exactly periodic; real physical sampling procedures may introduce errors in the placement of the sample points. This paper studies the effect of errors in sample positioning on the variance of estimators in the case of one-dimensional systematic sampling. First we sketch a general approach to variance...

  16. 2015 Long-Term Hydrologic Monitoring Program Sampling and Analysis Results at Rio Blanco, Colorado

    Energy Technology Data Exchange (ETDEWEB)

    Findlay, Rick [Nararro Research and Engineering, Oak Ridge, TN (United States); Kautsky, Mark [US Department of Energy, Washington, DC (United States). Office of Legacy Management

    2015-12-01

    The U.S. Department of Energy (DOE) Office of Legacy Management conducted annual sampling at the Rio Blanco, Colorado, Site for the Long-Term Hydrologic Monitoring Program (LTHMP) on May 20–21, 2015. This report documents the analytical results of the Rio Blanco annual monitoring event, the trip report, and the data validation package. The groundwater and surface water monitoring samples were shipped to the GEL Group Inc. laboratories for conventional analysis of tritium and analysis of gamma-emitting radionuclides by high-resolution gamma spectrometry. A subset of water samples collected from wells near the Rio Blanco site was also sent to GEL Group Inc. for enriched tritium analysis. All requested analyses were successfully completed. Samples were collected from a total of four onsite wells, including two that are privately owned. Samples were also collected from two additional private wells at nearby locations and from nine surface water locations. Samples were analyzed for gamma-emitting radionuclides by high-resolution gamma spectrometry, and they were analyzed for tritium using the conventional method with a detection limit on the order of 400 picocuries per liter (pCi/L). Four locations (one well and three surface locations) were analyzed using the enriched tritium method, which has a detection limit on the order of 3 pCi/L. The enriched locations included the well at the Brennan Windmill and surface locations at CER-1, CER-4, and Fawn Creek 500 feet upstream.

  17. 40 CFR 761.283 - Determination of the number of samples to collect and sample collection locations.

    Science.gov (United States)

    2010-07-01

    ...) MANUFACTURING, PROCESSING, DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS Sampling To Verify Completion of Self... cleanup verification conducted in accordance with § 761.61(a)(6), follow the procedures in paragraph (b... verification conducted in accordance with § 761.61(a)(6), follow the procedures in this section for locating...

  18. Summary of Test Results for Daya Bay Rock Samples

    International Nuclear Information System (INIS)

    Onishi, Celia Tiemi; Dobson, Patrick; Nakagawa, Seiji

    2004-01-01

    A series of analytical tests was conducted on a suite of granitic rock samples from the Daya Bay region of southeast China. The objective of these analyses was to determine key rock properties that would affect the suitability of this location for the siting of a neutrino oscillation experiment. This report contains the results of chemical analyses, rock property measurements, and a calculation of the mean atomic weight

  19. A comparison of temporal and location-based sampling strategies for global positioning system-triggered electronic diaries.

    Science.gov (United States)

    Törnros, Tobias; Dorn, Helen; Reichert, Markus; Ebner-Priemer, Ulrich; Salize, Hans-Joachim; Tost, Heike; Meyer-Lindenberg, Andreas; Zipf, Alexander

    2016-11-21

    Self-reporting is a well-established approach within the medical and psychological sciences. In order to avoid recall bias, i.e. past events being remembered inaccurately, the reports can be filled out on a smartphone in real-time and in the natural environment. This is often referred to as ambulatory assessment and the reports are usually triggered at regular time intervals. With this sampling scheme, however, rare events (e.g. a visit to a park or recreation area) are likely to be missed. When addressing the correlation between mood and the environment, it may therefore be beneficial to include participant locations within the ambulatory assessment sampling scheme. Based on the geographical coordinates, the database query system then decides if a self-report should be triggered or not. We simulated four different ambulatory assessment sampling schemes based on movement data (coordinates by minute) from 143 voluntary participants tracked for seven consecutive days. Two location-based sampling schemes incorporating the environmental characteristics (land use and population density) at each participant's location were introduced and compared to a time-based sampling scheme triggering a report on the hour as well as to a sampling scheme incorporating physical activity. We show that location-based sampling schemes trigger a report less often, but we obtain more unique trigger positions and a greater spatial spread in comparison to sampling strategies based on time and distance. Additionally, the location-based methods trigger significantly more often at rarely visited types of land use and less often outside the study region where no underlying environmental data are available.

  20. CFD modelling of sampling locations for early detection of spontaneous combustion in long-wall gob areas.

    Science.gov (United States)

    Yuan, Liming; Smith, Alex C

    In this study, computational fluid dynamics (CFD) modeling was conducted to optimize gas sampling locations for the early detection of spontaneous heating in longwall gob areas. Initial simulations were carried out to predict carbon monoxide (CO) concentrations at various regulators in the gob using a bleeder ventilation system. Measured CO concentration values at these regulators were then used to calibrate the CFD model. The calibrated CFD model was used to simulate CO concentrations at eight sampling locations in the gob using a bleederless ventilation system to determine the optimal sampling locations for early detection of spontaneous combustion.

  1. Seasonal rationalization of river water quality sampling locations: a comparative study of the modified Sanders and multivariate statistical approaches.

    Science.gov (United States)

    Varekar, Vikas; Karmakar, Subhankar; Jha, Ramakar

    2016-02-01

    The design of surface water quality sampling location is a crucial decision-making process for rationalization of monitoring network. The quantity, quality, and types of available dataset (watershed characteristics and water quality data) may affect the selection of appropriate design methodology. The modified Sanders approach and multivariate statistical techniques [particularly factor analysis (FA)/principal component analysis (PCA)] are well-accepted and widely used techniques for design of sampling locations. However, their performance may vary significantly with quantity, quality, and types of available dataset. In this paper, an attempt has been made to evaluate performance of these techniques by accounting the effect of seasonal variation, under a situation of limited water quality data but extensive watershed characteristics information, as continuous and consistent river water quality data is usually difficult to obtain, whereas watershed information may be made available through application of geospatial techniques. A case study of Kali River, Western Uttar Pradesh, India, is selected for the analysis. The monitoring was carried out at 16 sampling locations. The discrete and diffuse pollution loads at different sampling sites were estimated and accounted using modified Sanders approach, whereas the monitored physical and chemical water quality parameters were utilized as inputs for FA/PCA. The designed optimum number of sampling locations for monsoon and non-monsoon seasons by modified Sanders approach are eight and seven while that for FA/PCA are eleven and nine, respectively. Less variation in the number and locations of designed sampling sites were obtained by both techniques, which shows stability of results. A geospatial analysis has also been carried out to check the significance of designed sampling location with respect to river basin characteristics and land use of the study area. Both methods are equally efficient; however, modified Sanders

  2. Assessment of the LV-C2 Stack Sampling Probe Location for Compliance with ANSI/HPS N13.1-1999

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, John A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Antonio, Ernest J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Flaherty, Julia E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-09-01

    This document reports on a series of tests conducted to assess the proposed air sampling location for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) C2V (LV-C2) exhaust stack with respect to the applicable criteria regarding the placement of an air sampling probe. Federal regulations require that a sampling probe be located in the exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream. The tests were conducted on the LV-C2 scale model system. Based on the scale model tests, the location proposed for the air sampling probe in the scale model stack meets the requirements of the ANSI/HPS N13.1-1999 standard for velocity uniformity, flow angle, gas tracer and particle tracer uniformity. Additional velocity uniformity and flow angle tests on the actual stack will be necessary during cold startup to confirm the validity of the scale model results in representing the actual stack.

  3. Use of Loran-C navigation system to accurately determine sampling site location in an above ground cooling reservoir

    International Nuclear Information System (INIS)

    Lockwood, R.E.; Blankinship, D.R.

    1994-01-01

    Environmental monitoring programs often require accurate determination of sampling site locations in aquatic environments. This is especially true when a open-quotes pictureclose quotes of high resolution is needed for observing a changing variable in a given area and location is assumed to be important to the distribution of that variable. Sample site location can be difficult if few visible land marks are available for reference on a large body of water. The use of navigational systems such as Global Positioning System (GPS) and its predecessor, Loran-C, provide an excellent method for sample site location. McFarland (1992) discusses the practicality of GPS for location determination. This article discusses the use of Loran-C in a sampling scheme implemented at the South Texas Project Electrical Generating Station (STPEGS), Wadsworth, Texas

  4. Location and multi-depot vehicle routing for emergency vehicles using tour coverage and random sampling

    Directory of Open Access Journals (Sweden)

    Alireza Goli

    2015-09-01

    Full Text Available Distribution and optimum allocation of emergency resources are the most important tasks, which need to be accomplished during crisis. When a natural disaster such as earthquake, flood, etc. takes place, it is necessary to deliver rescue efforts as quickly as possible. Therefore, it is important to find optimum location and distribution of emergency relief resources. When a natural disaster occurs, it is not possible to reach some damaged areas. In this paper, location and multi-depot vehicle routing for emergency vehicles using tour coverage and random sampling is investigated. In this study, there is no need to visit all the places and some demand points receive their needs from the nearest possible location. The proposed study is implemented for some randomly generated numbers in different sizes. The preliminary results indicate that the proposed method was capable of reaching desirable solutions in reasonable amount of time.

  5. Robustness to non-normality of various tests for the one-sample location problem

    Directory of Open Access Journals (Sweden)

    Michelle K. McDougall

    2004-01-01

    Full Text Available This paper studies the effect of the normal distribution assumption on the power and size of the sign test, Wilcoxon's signed rank test and the t-test when used in one-sample location problems. Power functions for these tests under various skewness and kurtosis conditions are produced for several sample sizes from simulated data using the g-and-k distribution of MacGillivray and Cannon [5].

  6. Gasbuggy, New Mexico, Hydrologic and Natural Gas Sampling and Analysis Results for 2009

    International Nuclear Information System (INIS)

    2009-11-01

    The U.S. Department of Energy (DOE) Office of Legacy Management conducted hydrologic and natural gas sampling for the Gasbuggy, New Mexico, site on June 16, and 17, 2009. Hydrologic sampling consists of collecting water samples from water wells and surface water locations. Natural gas sampling consists of collecting both gas samples and samples of produced water from gas production wells. The water well samples were analyzed for gamma-emitting radionuclides and tritium. Surface water samples were analyzed for tritium. Water samples from gas production wells were analyzed for gamma-emitting radionuclides, gross alpha, gross beta, and tritium. Natural gas samples were analyzed for tritium and carbon-14. Water samples were analyzed by ALS Laboratory Group in Fort Collins, Colorado, and natural gas samples were analyzed by Isotech Laboratories in Champaign, Illinois. Concentrations of tritium and gamma-emitting radionuclides in water samples collected in the vicinity of the Gasbuggy site continue to demonstrate that the sample locations have not been impacted by detonation-related contaminants. Results from the sampling of natural gas from producing wells demonstrate that the gas wells nearest the Gasbuggy site are not currently impacted by detonation-related contaminants. Annual sampling of the gas production wells nearest the Gasbuggy site for gas and produced water will continue for the foreseeable future. The sampling frequency of water wells and surface water sources in the surrounding area will be reduced to once every 5 years. The next hydrologic sampling event at water wells, springs, and ponds will be in 2014.

  7. [Strategies for biobank networks. Classification of different approaches for locating samples and an outlook on the future within the BBMRI-ERIC].

    Science.gov (United States)

    Lablans, Martin; Kadioglu, Dennis; Mate, Sebastian; Leb, Ines; Prokosch, Hans-Ulrich; Ückert, Frank

    2016-03-01

    Medical research projects often require more biological material than can be supplied by a single biobank. For this reason, a multitude of strategies support locating potential research partners with matching material without requiring centralization of sample storage. Classification of different strategies for biobank networks, in particular for locating suitable samples. Description of an IT infrastructure combining these strategies. Existing strategies can be classified according to three criteria: (a) granularity of sample data: coarse bank-level data (catalogue) vs. fine-granular sample-level data, (b) location of sample data: central (central search service) vs. decentral storage (federated search services), and (c) level of automation: automatic (query-based, federated search service) vs. semi-automatic (inquiry-based, decentral search). All mentioned search services require data integration. Metadata help to overcome semantic heterogeneity. The "Common Service IT" in BBMRI-ERIC (Biobanking and BioMolecular Resources Research Infrastructure) unites a catalogue, the decentral search and metadata in an integrated platform. As a result, researchers receive versatile tools to search suitable biomaterial, while biobanks retain a high degree of data sovereignty. Despite their differences, the presented strategies for biobank networks do not rule each other out but can complement and even benefit from each other.

  8. From the SEM (IAEA) to the SIMS (ITU): Re-location experiment of μm-size particles - first results

    International Nuclear Information System (INIS)

    Admon, U.; Donohue, D.; Aigner, H.; Tamborini, G.; Bildstein, O.; Betti, M.

    2002-01-01

    -deposition of thin metallic layer through 'finder grid' masks [1], without affecting the particles themselves. The sample was then screened, using the automated EDAX/FEI Particle Analysis software in the XL-30 SEM, and about a hundred U-containing POIs were identified and their locations measured in several repeated runs. The initial particle search, as well as the re-location process afterwards, can be done in either automated (A) or manual (M) mode. The feasibility of the re-location method was tested in 3 types of SEM-to-SEM experiments (A/A, A/M, M/M), and in a SEM-to-SIMS experiment. The latter is invariably of the M/M type, in view of the destructive nature of the SIMS analysis, which calls for a thorough SEM characterization (and thus for manual re-location) of the selected POIs before the sample is transferred to the SIMS. Low magnification images of the search area are taken, to serve as maps enabling the visual identification of the individual particles according to their distribution patterns. The first test was a 'SEM to SEM' experiment. After the initial screening, which yielded a list P of POIs, {p i }, each defined by its SEM stage coordinates, the sample was removed from the SEM stage and then re-inserted in an arbitrary new position. The stage-coordinates of the reference marks were re-determined, their values used for predicting the new locations of {p i } where they are expected to appear in the second run. Then, a second automated particle search has been conducted, resulting in a list Q of POIs, {q j }. P and Q are not identical, and exhibit a different internal order. The problem of matching the particles which appear in both groups will be discussed elsewhere. Here, the manual re-location process will be reported. Out of the particles that appear in P intersection Q, 22 U-containing particles and 8 others (Al, SiO 2 etc.) were selected, visually identified with the aid of the picture maps, and manually brought to the central point of the SEM field of view

  9. An empirical comparison of respondent-driven sampling, time location sampling, and snowball sampling for behavioral surveillance in men who have sex with men, Fortaleza, Brazil.

    Science.gov (United States)

    Kendall, Carl; Kerr, Ligia R F S; Gondim, Rogerio C; Werneck, Guilherme L; Macena, Raimunda Hermelinda Maia; Pontes, Marta Kerr; Johnston, Lisa G; Sabin, Keith; McFarland, Willi

    2008-07-01

    Obtaining samples of populations at risk for HIV challenges surveillance, prevention planning, and evaluation. Methods used include snowball sampling, time location sampling (TLS), and respondent-driven sampling (RDS). Few studies have made side-by-side comparisons to assess their relative advantages. We compared snowball, TLS, and RDS surveys of men who have sex with men (MSM) in Forteleza, Brazil, with a focus on the socio-economic status (SES) and risk behaviors of the samples to each other, to known AIDS cases and to the general population. RDS produced a sample with wider inclusion of lower SES than snowball sampling or TLS-a finding of health significance given the majority of AIDS cases reported among MSM in the state were low SES. RDS also achieved the sample size faster and at lower cost. For reasons of inclusion and cost-efficiency, RDS is the sampling methodology of choice for HIV surveillance of MSM in Fortaleza.

  10. Identification of Clusters of Foot Pain Location in a Community Sample.

    Science.gov (United States)

    Gill, Tiffany K; Menz, Hylton B; Landorf, Karl B; Arnold, John B; Taylor, Anne W; Hill, Catherine L

    2017-12-01

    To identify foot pain clusters according to pain location in a community-based sample of the general population. This study analyzed data from the North West Adelaide Health Study. Data were obtained between 2004 and 2006, using computer-assisted telephone interviewing, clinical assessment, and self-completed questionnaire. The location of foot pain was assessed using a diagram during the clinical assessment. Hierarchical cluster analysis was undertaken to identify foot pain location clusters, which were then compared in relation to demographics, comorbidities, and podiatry services utilization. There were 558 participants with foot pain (mean age 54.4 years, 57.5% female). Five clusters were identified: 1 with predominantly arch and ball pain (26.8%), 1 with rearfoot pain (20.9%), 1 with heel pain (13.3%), and 2 with predominantly forefoot, toe, and nail pain (28.3% and 10.7%). Each cluster was distinct in age, sex, and comorbidity profile. Of the two clusters with predominantly forefoot, toe, and nail pain, one of them had a higher proportion of men and those classified as obese, had diabetes mellitus, and used podiatry services (30%), while the other was comprised of a higher proportion of women who were overweight and reported less use of podiatry services (17.5%). Five clusters of foot pain according to pain location were identified, all with distinct age, sex, and comorbidity profiles. These findings may assist in the identification of individuals at risk for developing foot pain and in the development of targeted preventive strategies and treatments. © 2017, American College of Rheumatology.

  11. Assessment of the LV-S2 & LV-S3 Stack Sampling Probe Locations for Compliance with ANSI/HPS N13.1-1999

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, John A.; Antonio, Ernest J.; Flaherty, Julia E.; Amidan, Brett G.

    2014-09-30

    This document reports on a series of tests conducted to assess the proposed air sampling locations for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Group 1-2A exhaust stacks with respect to the applicable criteria regarding the placement of an air sampling probe. The LV-C2, LV-S2, and LV-S3 exhaust stacks were tested together as a group (Test Group 1-2A). This report only covers the results of LV-S2 and LV-S3; LV-C2 will be reported on separately. Federal regulations1 require that a sampling probe be located in the exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. 2 These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream.

  12. 40 CFR 141.703 - Sampling locations.

    Science.gov (United States)

    2010-07-01

    ... samples prior to the point of filter backwash water addition. (d) Bank filtration. (1) Systems that... applicable, must collect source water samples in the surface water prior to bank filtration. (2) Systems that use bank filtration as pretreatment to a filtration plant must collect source water samples from the...

  13. Location tests for biomarker studies: a comparison using simulations for the two-sample case.

    Science.gov (United States)

    Scheinhardt, M O; Ziegler, A

    2013-01-01

    Gene, protein, or metabolite expression levels are often non-normally distributed, heavy tailed and contain outliers. Standard statistical approaches may fail as location tests in this situation. In three Monte-Carlo simulation studies, we aimed at comparing the type I error levels and empirical power of standard location tests and three adaptive tests [O'Gorman, Can J Stat 1997; 25: 269 -279; Keselman et al., Brit J Math Stat Psychol 2007; 60: 267- 293; Szymczak et al., Stat Med 2013; 32: 524 - 537] for a wide range of distributions. We simulated two-sample scenarios using the g-and-k-distribution family to systematically vary tail length and skewness with identical and varying variability between groups. All tests kept the type I error level when groups did not vary in their variability. The standard non-parametric U-test performed well in all simulated scenarios. It was outperformed by the two non-parametric adaptive methods in case of heavy tails or large skewness. Most tests did not keep the type I error level for skewed data in the case of heterogeneous variances. The standard U-test was a powerful and robust location test for most of the simulated scenarios except for very heavy tailed or heavy skewed data, and it is thus to be recommended except for these cases. The non-parametric adaptive tests were powerful for both normal and non-normal distributions under sample variance homogeneity. But when sample variances differed, they did not keep the type I error level. The parametric adaptive test lacks power for skewed and heavy tailed distributions.

  14. MUSIC ALGORITHM FOR LOCATING POINT-LIKE SCATTERERS CONTAINED IN A SAMPLE ON FLAT SUBSTRATE

    Institute of Scientific and Technical Information of China (English)

    Dong Heping; Ma Fuming; Zhang Deyue

    2012-01-01

    In this paper,we consider a MUSIC algorithm for locating point-like scatterers contained in a sample on flat substrate.Based on an asymptotic expansion of the scattering amplitude proposed by Ammari et al.,the reconstruction problem can be reduced to a calculation of Green function corresponding to the background medium.In addition,we use an explicit formulation of Green function in the MUSIC algorithm to simplify the calculation when the cross-section of sample is a half-disc.Numerical experiments are included to demonstrate the feasibility of this method.

  15. 1999 Baseline Sampling and Analysis Sampling Locations, Geographic NAD83, LOSCO (2004) [BSA_1999_sample_locations_LOSCO_2004

    Data.gov (United States)

    Louisiana Geographic Information Center — The monitor point data set was produced as a part of the Baseline Sampling and Analysis program coordinated by the Louisiana Oil Spill Coordinator's Office. This...

  16. 1997 Baseline Sampling and Analysis Sample Locations, Geographic NAD83, LOSCO (2004) [BSA_1997_sample_locations_LOSCO_2004

    Data.gov (United States)

    Louisiana Geographic Information Center — The monitor point data set was produced as a part of the Baseline Sampling and Analysis (BSA) program coordinated by the Louisiana Oil Spill Coordinator's Office....

  17. 1998 Baseline Sampling and Analysis Sampling Locations, Geographic NAD83, LOSCO (2004) [BSA_1998_sample_locations_LOSCO_2004

    Data.gov (United States)

    Louisiana Geographic Information Center — The monitor point data set was produced as a part of the Baseline Sampling and Analysis program coordinated by the Louisiana Oil Spill Coordinator's Office. This...

  18. Use of space-filling curves to select sample locations in natural resource monitoring studies

    Science.gov (United States)

    Andrew Lister; Charles T. Scott

    2009-01-01

    The establishment of several large area monitoring networks over the past few decades has led to increased research into ways to spatially balance sample locations across the landscape. Many of these methods are well documented and have been used in the past with great success. In this paper, we present a method using geographic information systems (GIS) and fractals...

  19. Estrogenic and esterase-inhibiting potency in rainwater in relation to pesticide concentrations, sampling season and location

    Energy Technology Data Exchange (ETDEWEB)

    Hamers, T.; Brink, P.J. van den; Mos, L.; Linden, S.C. van der; Legler, J.; Koeman, J.H.; Murk, A.J

    2003-05-01

    Estrogenic potency of rainwater correlated well with organochlorine concentrations, but could not be attributed to specific pesticides. - In a year-round monitoring program (1998), pesticide composition and toxic potency of the mix of pollutants present in rainwater were measured. The goal of the study was to relate atmospheric deposition of toxic potency and pesticide composition to each other and to sampling period and local agricultural activity. Rainwater was collected in 26 consecutive periods of 14 days in a background location (BACK) and in two locations representative for different agricultural practices, i.e. intensive greenhouse horticulture (HORT) and flower bulb culture (BULB). Samples were chemically analyzed for carbamate (CARB), organophosphate (OP) and organochlorine (OC) pesticides and metabolites. Esterase inhibiting potency of rainwater extracts was measured in a specially developed bio-assay with honeybee esterases and was expressed as an equivalent concentration of the model inhibitor dichlorvos. Estrogenic potency of the extracts was measured in the ER-CALUX reporter gene assay and was expressed as an equivalent concentration of estradiol. Multivariate principal component analysis (PCA) techniques proved to be valuable tools to analyze the numerous pesticide concentrations in relation to toxic potency, sampling location, and sampling season. Pesticide composition in rainwater depended much more on sampling season than on sampling location, but differences between SPRING and SUMMER were mainly attributed to local differences in agricultural practice. On average, the esterase inhibiting potency exceeded the maximum permissible concentration set for dichlorvos in The Netherlands, and was significantly higher in HORT than in BACK and BULB. Esterase inhibition correlated significantly with OP and CARB concentrations, as expected given the working mechanism of these insecticides. The estrogenic potency incidentally exceeded NOEC levels reported for

  20. Estrogenic and esterase-inhibiting potency in rainwater in relation to pesticide concentrations, sampling season and location

    International Nuclear Information System (INIS)

    Hamers, T.; Brink, P.J. van den; Mos, L.; Linden, S.C. van der; Legler, J.; Koeman, J.H.; Murk, A.J.

    2003-01-01

    Estrogenic potency of rainwater correlated well with organochlorine concentrations, but could not be attributed to specific pesticides. - In a year-round monitoring program (1998), pesticide composition and toxic potency of the mix of pollutants present in rainwater were measured. The goal of the study was to relate atmospheric deposition of toxic potency and pesticide composition to each other and to sampling period and local agricultural activity. Rainwater was collected in 26 consecutive periods of 14 days in a background location (BACK) and in two locations representative for different agricultural practices, i.e. intensive greenhouse horticulture (HORT) and flower bulb culture (BULB). Samples were chemically analyzed for carbamate (CARB), organophosphate (OP) and organochlorine (OC) pesticides and metabolites. Esterase inhibiting potency of rainwater extracts was measured in a specially developed bio-assay with honeybee esterases and was expressed as an equivalent concentration of the model inhibitor dichlorvos. Estrogenic potency of the extracts was measured in the ER-CALUX reporter gene assay and was expressed as an equivalent concentration of estradiol. Multivariate principal component analysis (PCA) techniques proved to be valuable tools to analyze the numerous pesticide concentrations in relation to toxic potency, sampling location, and sampling season. Pesticide composition in rainwater depended much more on sampling season than on sampling location, but differences between SPRING and SUMMER were mainly attributed to local differences in agricultural practice. On average, the esterase inhibiting potency exceeded the maximum permissible concentration set for dichlorvos in The Netherlands, and was significantly higher in HORT than in BACK and BULB. Esterase inhibition correlated significantly with OP and CARB concentrations, as expected given the working mechanism of these insecticides. The estrogenic potency incidentally exceeded NOEC levels reported for

  1. GeoSearcher: Location-Based Ranking of Search Engine Results.

    Science.gov (United States)

    Watters, Carolyn; Amoudi, Ghada

    2003-01-01

    Discussion of Web queries with geospatial dimensions focuses on an algorithm that assigns location coordinates dynamically to Web sites based on the URL. Describes a prototype search system that uses the algorithm to re-rank search engine results for queries with a geospatial dimension, thus providing an alternative ranking order for search engine…

  2. Results of groundwater monitoring and vegetation sampling at Everest, Kansas, in 2009 .

    Energy Technology Data Exchange (ETDEWEB)

    LaFreniere, L. M.; Environmental Science Division

    2010-05-13

    effectively, identified by the existing network of monitoring points and have not changed significantly during the CCC/USDA investigation program. The carbon tetrachloride distribution within the plume has continued to evolve, however, with relatively constant or apparently decreasing contaminant levels at most sampling locations. In response to these findings, the KDHE requested that the CCC/USDA develop a plan for annual monitoring of the groundwater and surface water at Everest, to facilitate continued tracking of the carbon tetrachloride plume at this site (KDHE 2009a). A recommendation for annual sampling (for analyses of VOCs) of 16 existing groundwater monitoring points within and near the identified contaminant migration pathway and surface water sampling at 5 locations along the intermittent creek west (downgradient) of the identified plume was presented by the CCC/USDA (Appendix A) and approved by the KDHE (2009b) for implementation. The monitoring wells will be sampled according to the low-flow procedure, and sample preservation, shipping, and analysis activities will be consistent with previous work at Everest. The annual sampling will continue until identified conditions at the site indicate a technical justification for a change. This report summarizes the results of sampling and monitoring activities conducted at the Everest site since completion of the April 2008 groundwater sampling event (Argonne 2008). The investigations performed during the current review period (May 2008 to October 2009) were as follows: (1) With one exception, the KDHE-approved groundwater and surface water monitoring points were sampled on April 24-27, 2009. In this event, well PT1 was inadvertently sampled instead of the adjacent well MW04. This investigation represents the first groundwater and surface water sampling event performed under the current plan for annual monitoring approved by the KDHE. (2) Ongoing monitoring of the groundwater levels at Everest is performed with KDHE

  3. Reference Priors for the General Location-Scale Model

    NARCIS (Netherlands)

    Fernández, C.; Steel, M.F.J.

    1997-01-01

    The reference prior algorithm (Berger and Bernardo 1992) is applied to multivariate location-scale models with any regular sampling density, where we establish the irrelevance of the usual assumption of Normal sampling if our interest is in either the location or the scale. This result immediately

  4. Fixed-location hydroacoustic monitoring designs for estimating fish passage using stratified random and systematic sampling

    International Nuclear Information System (INIS)

    Skalski, J.R.; Hoffman, A.; Ransom, B.H.; Steig, T.W.

    1993-01-01

    Five alternate sampling designs are compared using 15 d of 24-h continuous hydroacoustic data to identify the most favorable approach to fixed-location hydroacoustic monitoring of salmonid outmigrants. Four alternative aproaches to systematic sampling are compared among themselves and with stratified random sampling (STRS). Stratifying systematic sampling (STSYS) on a daily basis is found to reduce sampling error in multiday monitoring studies. Although sampling precision was predictable with varying levels of effort in STRS, neither magnitude nor direction of change in precision was predictable when effort was varied in systematic sampling (SYS). Furthermore, modifying systematic sampling to include replicated (e.g., nested) sampling (RSYS) is further shown to provide unbiased point and variance estimates as does STRS. Numerous short sampling intervals (e.g., 12 samples of 1-min duration per hour) must be monitored hourly using RSYS to provide efficient, unbiased point and interval estimates. For equal levels of effort, STRS outperformed all variations of SYS examined. Parametric approaches to confidence interval estimates are found to be superior to nonparametric interval estimates (i.e., bootstrap and jackknife) in estimating total fish passage. 10 refs., 1 fig., 8 tabs

  5. Assessment of the National Research Universal Reactor Proposed New Stack Sampling Probe Location for Compliance with ANSI/HPS N13.1-1999

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, John A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Antonio, Ernest J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Flaherty, Julia E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-29

    This document reports on a series of tests conducted to assess the proposed air sampling location for the National Research Universal reactor (NRU) complex exhaust stack, located in Chalk River, Ontario, Canada, with respect to the applicable criteria regarding the placement of an air sampling probe. Due to the age of the equipment in the existing monitoring system, and the increasing difficulty in acquiring replacement parts to maintain this equipment, a more up-to-date system is planned to replace the current effluent monitoring system, and a new monitoring location has been proposed. The new sampling probe should be located within the exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream. The internal Pacific Northwest National Laboratory (PNNL) project for this task was 65167, Atomic Energy Canada Ltd. Chalk River Effluent Duct Flow Qualification. The testing described in this document was guided by the Test Plan: Testing of the NRU Stack Air Sampling Position (TP-STMON-032).

  6. Robustness to non-normality of common tests for the many-sample location problem

    Directory of Open Access Journals (Sweden)

    Azmeri Khan

    2003-01-01

    Full Text Available This paper studies the effect of deviating from the normal distribution assumption when considering the power of two many-sample location test procedures: ANOVA (parametric and Kruskal-Wallis (non-parametric. Power functions for these tests under various conditions are produced using simulation, where the simulated data are produced using MacGillivray and Cannon's [10] recently suggested g-and-k distribution. This distribution can provide data with selected amounts of skewness and kurtosis by varying two nearly independent parameters.

  7. Evaluation of sampling inhalable PM10 particulate matter (≤ 10 μm) using co-located high volume samplers

    International Nuclear Information System (INIS)

    Rajoy, R R S; Dias, J W C; Rego, E C P; Netto, A D Pereira

    2015-01-01

    This paper presents the results of the determination of the concentrations of atmospheric particulate matter ≤ 10 μm (PM10), collected simultaneously by six PM10 high volume samplers from two different manufacturers installed in the same location. Fifteen samples of 24 h were obtained with each equipment at a selected urban area of Rio de Janeiro city. The concentration of PM10 ranged between 10.73 and 54.04 μg m −3 . The samplers were considered comparable to each other, as the adopted methodology presented good repeatability

  8. Analytical results for 544 water samples collected in the Attean Quartz Monzonite in the vicinity of Jackman, Maine

    Science.gov (United States)

    Ficklin, W.H.; Nowlan, G.A.; Preston, D.J.

    1983-01-01

    Water samples were collected in the vicinity of Jackman, Maine as a part of the study of the relationship of dissolved constituents in water to the sediments subjacent to the water. Each sample was analyzed for specific conductance, alkalinity, acidity, pH, fluoride, chloride, sulfate, phosphate, nitrate, sodium, potassium, calcium, magnesium, and silica. Trace elements determined were copper, zinc, molybdenum, lead, iron, manganese, arsenic, cobalt, nickel, and strontium. The longitude and latitude of each sample location and a sample site map are included in the report as well as a table of the analytical results.

  9. Recent Results from the SAMPLE Experiment

    International Nuclear Information System (INIS)

    Ito, Takeyasu M.

    2004-01-01

    The previous two SAMPLE experiments yielded a measurement of the axial e-N form factor G A e substantially different from the theoretical estimate. In order to confirm this observation, a third SAMPLE experiment was carried out at a lower beam energy of 125 MeV (Q2 = 0.038 (GeV/c)2) on a deuterium target. The data analysis is now at the final stage and the results are consistent with the theoretical prediction of the axial form factor G A e . Also, reevaluation of the background dilution factor and the electromagnetic radiative correction for the 200 MeV deuterium data lead to updated results, which are also consistent with the theoretical prediction

  10. Statistical literacy and sample survey results

    Science.gov (United States)

    McAlevey, Lynn; Sullivan, Charles

    2010-10-01

    Sample surveys are widely used in the social sciences and business. The news media almost daily quote from them, yet they are widely misused. Using students with prior managerial experience embarking on an MBA course, we show that common sample survey results are misunderstood even by those managers who have previously done a statistics course. In general, they fare no better than managers who have never studied statistics. There are implications for teaching, especially in business schools, as well as for consulting.

  11. First Results from the LHCb Vertex Locator

    CERN Multimedia

    Borghi, S

    2010-01-01

    LHCb is a dedicated experiment to study new physics in the decays of beauty and charm hadrons at the Large Hadron Collider (LHC) at CERN. The beauty and charm hadrons are identified through their flight distance in the Vertex Locator (VELO), and hence the detector is critical for both the trigger and offline physics analyses. The VELO is the silicon detector surrounding the interaction point, and is the closest LHC vertex detector to the interaction point, located only 7 mm from the LHC beam during normal operation. The detector will operate in an extreme and highly non-uniform radiation environment. The VELO consists of two retractable detector halves with 21 silicon micro-strip tracking modules each. A module is composed of two n+-on-n 300 micron thick half disc sensors with R-measuring and Phi-measuring micro-strip geometry, mounted on a carbon fibre support paddle. The minimum pitch is approximately 40 $\\mu$m. The detector is also equipped with one n-on-p module. The detectors are operated in vacuum and a...

  12. Development of failed fuel detection and location system in sodium-cooled large reactor. Sampling method of failed fuels under the slit

    International Nuclear Information System (INIS)

    Aizawa, Kousuke; Fujita, Kaoru; Kamide, Hideki; Kasahara, Naoto

    2010-01-01

    A conceptual design study of Japan Sodium-cooled Fast Reactor (JSFR) is in progress as an issue of the 'Fast Reactor Cycle Technology Development (FaCT)' project in Japan. JSFR adopts a Selector-Valve mechanism for the failed fuel detection and location (FFDL) system. The Selector-Valve FFDL system identifies failed fuel subassemblies by sampling sodium from each fuel subassembly outlet and detecting fission product. One of the JSFR design features is employing an upper internal structure (UIS) with a radial slit, in which an arm of fuel handling machine can move and access the fuel assemblies under the UIS. Thus, JSFR cannot place sampling nozzles right above the fuel subassemblies located under the slit. In this study, the sampling method for indentifying under-slit failed fuel subassemblies has been demonstrated by water experiments. (author)

  13. Locating Longitudinal Respondents After a 50-Year Hiatus

    Directory of Open Access Journals (Sweden)

    Stone Celeste

    2014-06-01

    Full Text Available Many longitudinal and follow-up studies face a common challenge: locating study participants. This study examines the extent to which a geographically dispersed subsample of participants can be relocated after 37 to 51 years of noncontact. Relying mostly on commercially available databases and administrative records, the 2011-12 Project Talent Follow-up Pilot Study (PTPS12 located nearly 85 percent of the original sample members, many of whom had not participated in the study since 1960. This study uses data collected in the base year to examine which subpopulations were the hardest to find after this extended hiatus. The results indicate that females were located at significantly lower rates than males. As expected, sample members with lower cognitive abilities were among the hardest-to-reach subpopulations. We next evaluate the extent to which biases introduced during the tracking phase can be minimized by using the multivariate chi-square automatic interaction detection (CHAID technique to calculate tracking loss adjustments. Unlike a 1995 study that found that these adjustments reduced statistical biases among its sample of located females, our results suggest that statistical adjustments were not as effective in PTPS12, where many participants had not been contacted in nearly 50 years and the tracking rates varied so greatly across subgroups.

  14. Sample Results from MCU Solids Outage

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T.; Washington, A.; Oji, L.; Coleman, C.; Poirier, M.

    2014-09-22

    Savannah River National Laboratory (SRNL) has received several solid and liquid samples from MCU in an effort to understand and recover from the system outage starting on April 6, 2014. SRNL concludes that the presence of solids in the Salt Solution Feed Tank (SSFT) is the likely root cause for the outage, based upon the following discoveries: A solids sample from the extraction contactor #1 proved to be mostly sodium oxalate; A solids sample from the scrub contactor#1 proved to be mostly sodium oxalate; A solids sample from the Salt Solution Feed Tank (SSFT) proved to be mostly sodium oxalate; An archived sample from Tank 49H taken last year was shown to contain a fine precipitate of sodium oxalate; A solids sample from ; A liquid sample from the SSFT was shown to have elevated levels of oxalate anion compared to the expected concentration in the feed. Visual inspection of the SSFT indicated the presence of precipitated or transferred solids, which were likely also in the Salt Solution Receipt Tank (SSRT). The presence of the solids coupled with agitation performed to maintain feed temperature resulted in oxalate solids migration through the MCU system and caused hydraulic issues that resulted in unplanned phase carryover from the extraction into the scrub, and ultimately the strip contactors. Not only did this carryover result in the Strip Effluent (SE) being pushed out of waste acceptance specification, but it resulted in the deposition of solids into several of the contactors. At the same time, extensive deposits of aluminosilicates were found in the drain tube in the extraction contactor #1. However it is not known at this time how the aluminosilicate solids are related to the oxalate solids. The solids were successfully cleaned out of the MCU system. However, future consideration must be given to the exclusion of oxalate solids into the MCU system. There were 53 recommendations for improving operations recently identified. Some additional considerations or

  15. Sampling Key Populations for HIV Surveillance: Results From Eight Cross-Sectional Studies Using Respondent-Driven Sampling and Venue-Based Snowball Sampling.

    Science.gov (United States)

    Rao, Amrita; Stahlman, Shauna; Hargreaves, James; Weir, Sharon; Edwards, Jessie; Rice, Brian; Kochelani, Duncan; Mavimbela, Mpumelelo; Baral, Stefan

    2017-10-20

    In using regularly collected or existing surveillance data to characterize engagement in human immunodeficiency virus (HIV) services among marginalized populations, differences in sampling methods may produce different pictures of the target population and may therefore result in different priorities for response. The objective of this study was to use existing data to evaluate the sample distribution of eight studies of female sex workers (FSW) and men who have sex with men (MSM), who were recruited using different sampling approaches in two locations within Sub-Saharan Africa: Manzini, Swaziland and Yaoundé, Cameroon. MSM and FSW participants were recruited using either respondent-driven sampling (RDS) or venue-based snowball sampling. Recruitment took place between 2011 and 2016. Participants at each study site were administered a face-to-face survey to assess sociodemographics, along with the prevalence of self-reported HIV status, frequency of HIV testing, stigma, and other HIV-related characteristics. Crude and RDS-adjusted prevalence estimates were calculated. Crude prevalence estimates from the venue-based snowball samples were compared with the overlap of the RDS-adjusted prevalence estimates, between both FSW and MSM in Cameroon and Swaziland. RDS samples tended to be younger (MSM aged 18-21 years in Swaziland: 47.6% [139/310] in RDS vs 24.3% [42/173] in Snowball, in Cameroon: 47.9% [99/306] in RDS vs 20.1% [52/259] in Snowball; FSW aged 18-21 years in Swaziland 42.5% [82/325] in RDS vs 8.0% [20/249] in Snowball; in Cameroon 15.6% [75/576] in RDS vs 8.1% [25/306] in Snowball). They were less educated (MSM: primary school completed or less in Swaziland 42.6% [109/310] in RDS vs 4.0% [7/173] in Snowball, in Cameroon 46.2% [138/306] in RDS vs 14.3% [37/259] in Snowball; FSW: primary school completed or less in Swaziland 86.6% [281/325] in RDS vs 23.9% [59/247] in Snowball, in Cameroon 87.4% [520/576] in RDS vs 77.5% [238/307] in Snowball) than the snowball

  16. Magnitude, direction and location of the resultant dipole moment of the pig heart.

    Science.gov (United States)

    Hodgkin, B C; Nelson, C V; Angelakos, E T

    1976-04-01

    Vectorcardiograms were obtained from 50 young domestic pigs using the Nelson lead system. Compensation for body size and shape is achieved and the resultant dipole moment magnitude reflects heart size. A strong relationship was found between heart size and maximum magnitude. Dipole moment magnitude increased as four pigs increased from five to ten weeks of age. The dipole moment during QRS is considered in light of known pig heart excitation pattern. Dipole locations during QRS, calculated by computer solution of the Gabor-Nelson equations, were in agreement with heart location and excitation data.

  17. Assessment of Heavy Metals in Water Samples of Certain Locations Situated Around Tumkur, Karnataka, India

    Directory of Open Access Journals (Sweden)

    C. Vijaya Bhaskar

    2010-01-01

    Full Text Available Surface water and groundwater samples of certain locations namely Kallambella, Bugudanahalli, Maidala, Honnudike, Kunigal, Kadaba and Hebbur, situated around Tumkur were assessed in the month of September 2008 for pH, EC and heavy metals Cd, Cu, Fe, Hg, Mn, Zn and Ni. The pH vales of surface waters were in alkaline range of 7.8-8.2 and are well within safe limits for crop production. The pH of ground- water was in the range of 7.6-8.4. The conductivity was in the range of 0.20-0.68 mS/cm and 0.34-2.44 mS/cm for surface and groundwaters respectively. High EC value of Kallambella groundwater accounts for its salinity. All surface waters except Honnudike and Hebbur samples contain low concentrations of these metals and are ideal for irrigation. Though the samples from Honnudike, Kadaba and Hebbur have high iron concentration, only Honnudike and Hebbur samples have exceeded the limit of 5 mg/L required for irrigation. In groundwaters the concentrations of all these heavy metals except copper are also well in permissible limits and suitable for drinking. Cu, Fe, Ni and Zn were detected in all the samples and found in the range of 0.094-0.131, 0.958-12.537, 0.020-0.036 and 0.082-1.139 mg/L respectively in surface waters and these are in the range of 0.132-0.142, 0.125-1.014, 0.028-0.036 and 0.003-0.037 mg/L in ground- waters. The elements cadmium, mercury and manganese are absent in all the samples.

  18. Control charts for location based on different sampling schemes

    NARCIS (Netherlands)

    Mehmood, R.; Riaz, M.; Does, R.J.M.M.

    2013-01-01

    Control charts are the most important statistical process control tool for monitoring variations in a process. A number of articles are available in the literature for the X̄ control chart based on simple random sampling, ranked set sampling, median-ranked set sampling (MRSS), extreme-ranked set

  19. Sample Results From Tank 48H Samples HTF-48-14-158, -159, -169, and -170

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hang, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-04-28

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 48H in support of determining the cause for the unusually high dose rates at the sampling points for this tank. A set of two samples was taken from the quiescent tank, and two additional samples were taken after the contents of the tank were mixed. The results of the analyses of all the samples show that the contents of the tank have changed very little since the analysis of the previous sample in 2012. The solids are almost exclusively composed of tetraphenylborate (TPB) salts, and there is no indication of acceleration in the TPB decomposition. The filtrate composition shows a moderate increase in salt concentration and density, which is attributable to the addition of NaOH for the purposes of corrosion control. An older modeling simulation of the TPB degradation was updated, and the supernate results from a 2012 sample were run in the model. This result was compared to the results from the 2014 recent sample results reported in this document. The model indicates there is no change in the TPB degradation from 2012 to 2014. SRNL measured the buoyancy of the TPB solids in Tank 48H simulant solutions. It was determined that a solution of density 1.279 g/mL (~6.5M sodium) was capable of indefinitely suspending the TPB solids evenly throughout the solution. A solution of density 1.296 g/mL (~7M sodium) caused a significant fraction of the solids to float on the solution surface. As the experiments could not include the effect of additional buoyancy elements such as benzene or hydrogen generation, the buoyancy measurements provide an upper bound estimate of the density in Tank 48H required to float the solids.

  20. Gene Locater

    DEFF Research Database (Denmark)

    Anwar, Muhammad Zohaib; Sehar, Anoosha; Rehman, Inayat-Ur

    2012-01-01

    software's for calculating recombination frequency is mostly limited to the range and flexibility of this type of analysis. GENE LOCATER is a fully customizable program for calculating recombination frequency, written in JAVA. Through an easy-to-use interface, GENE LOCATOR allows users a high degree...... of flexibility in calculating genetic linkage and displaying linkage group. Among other features, this software enables user to identify linkage groups with output visualized graphically. The program calculates interference and coefficient of coincidence with elevated accuracy in sample datasets. AVAILABILITY...

  1. SAMPLE RESULTS FROM THE INTEGRATED SALT DISPOSITION PROGRAM MACROBATCH 4 TANK 21H QUALIFICATION SAMPLES

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T.; Fink, S.

    2011-06-22

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H to qualify them for use in the Integrated Salt Disposition Program (ISDP) Batch 4 processing. All sample results agree with expectations based on prior analyses where available. No issues with the projected Salt Batch 4 strategy are identified. This revision includes additional data points that were not available in the original issue of the document, such as additional plutonium results, the results of the monosodium titanate (MST) sorption test and the extraction, scrub strip (ESS) test. This report covers the revision to the Tank 21H qualification sample results for Macrobatch (Salt Batch) 4 of the Integrated Salt Disposition Program (ISDP). A previous document covers initial characterization which includes results for a number of non-radiological analytes. These results were used to perform aluminum solubility modeling to determine the hydroxide needs for Salt Batch 4 to prevent the precipitation of solids. Sodium hydroxide was then added to Tank 21 and additional samples were pulled for the analyses discussed in this report. This work was specified by Task Technical Request and by Task Technical and Quality Assurance Plan (TTQAP).

  2. PIXE analysis of thin samples

    International Nuclear Information System (INIS)

    Kiss, Ildiko; Koltay, Ede; Szabo, Gyula; Laszlo, S.; Meszaros, A.

    1985-01-01

    Particle-induced X-ray emission (PIXE) multielemental analysis of thin film samples are reported. Calibration methods of K and L X-lines are discussed. Application of PIXE analysis to aerosol monitoring, multielement aerosol analysis is described. Results of PIXE analysis of samples from two locations in Hungary are compared with the results of aerosol samples from Scandinavia and the USA. (D.Gy.)

  3. Most Recent Sampling Results for Annex III Building

    Science.gov (United States)

    Contains email from Scott Miller, US EPA to Scott Kramer. Subject: Most Recent Sampling Results for Annex III Building. (2:52 PM) and Gore(TM) Surveys Analytical Results U.S. Geological Survey, Montgomery, AL.

  4. Determining the spatial variability of personal sampler inlet locations.

    Science.gov (United States)

    Vinson, Robert; Volkwein, Jon; McWilliams, Linda

    2007-09-01

    This article examines the spatial variability of dust concentrations within a coal miner's breathing zone and the impact of sampling location at the cap lamp, nose, and lapel. Tests were conducted in the National Institute for Safety and Health Pittsburgh Research Laboratory full-scale, continuous miner gallery using three prototype personal dust monitors (PDM). The dust masses detected by the PDMs were used to calculate the percentage difference of dust mass between the cap lamp and the nose and between the lapel and the nose. The calculated percentage differences of the masses ranged from plus 12% to minus 25%. Breathing zone tests were also conducted in four underground coal mines using the torso of a mannequin to simulate a miner. Coal mine dust was sampled with multi-cyclone sampling cans mounted directly in front of the mannequin near the cap lamp, nose, and lapel. These four coal mine tests found that the spatial variability of dust levels and imprecision of the current personal sampler is a greater influence than the sampler location within the breathing zone. However, a one-sample t-test of this data did find that the overall mean value of the cap lamp/nose ratio was not significantly different than 1 (p-value = 0.21). However, when applied to the overall mean value of the lapel/nose ratio there was a significant difference from 1 (p-value sampling location for coal mine dust samples. But these results suggest that the cap location is slightly more indicative of what is breathed through the nose area.

  5. Analytical results of Tank 38H core samples -- Fall 1999

    International Nuclear Information System (INIS)

    Swingle, R.F.

    2000-01-01

    Two samples were pulled from Tank 38H in the Fall of 1999: a variable depth sample (VDS) of the supernate was pulled in October and a core sample from the salt layer was pulled in December. Analysis of the rinse from the outside of the core sample indicated no sign of volatile or semivolatile organics. Both supernate and solids from the VDS and the dried core sample solids were analyzed for isotopes which could pose a criticality concern and also for elements which could serve as neutron poisons, as well as other elements. Results of the elemental analyses of these samples show significant elements present to mitigate the potential for nuclear criticality. However, it should be noted the results given for the VDS solids elemental analyses may be higher than the actual concentration in the solids, since the filter paper was dissolved along with the sample solids

  6. Kalman/Map Filtering-Aided Fast Normalized Cross Correlation-Based Wi-Fi Fingerprinting Location Sensing

    Directory of Open Access Journals (Sweden)

    Yongliang Sun

    2013-11-01

    Full Text Available A Kalman/map filtering (KMF-aided fast normalized cross correlation (FNCC-based Wi-Fi fingerprinting location sensing system is proposed in this paper. Compared with conventional neighbor selection algorithms that calculate localization results with received signal strength (RSS mean samples, the proposed FNCC algorithm makes use of all the on-line RSS samples and reference point RSS variations to achieve higher fingerprinting accuracy. The FNCC computes efficiently while maintaining the same accuracy as the basic normalized cross correlation. Additionally, a KMF is also proposed to process fingerprinting localization results. It employs a new map matching algorithm to nonlinearize the linear location prediction process of Kalman filtering (KF that takes advantage of spatial proximities of consecutive localization results. With a calibration model integrated into an indoor map, the map matching algorithm corrects unreasonable prediction locations of the KF according to the building interior structure. Thus, more accurate prediction locations are obtained. Using these locations, the KMF considerably improves fingerprinting algorithm performance. Experimental results demonstrate that the FNCC algorithm with reduced computational complexity outperforms other neighbor selection algorithms and the KMF effectively improves location sensing accuracy by using indoor map information and spatial proximities of consecutive localization results.

  7. Kalman/Map filtering-aided fast normalized cross correlation-based Wi-Fi fingerprinting location sensing.

    Science.gov (United States)

    Sun, Yongliang; Xu, Yubin; Li, Cheng; Ma, Lin

    2013-11-13

    A Kalman/map filtering (KMF)-aided fast normalized cross correlation (FNCC)-based Wi-Fi fingerprinting location sensing system is proposed in this paper. Compared with conventional neighbor selection algorithms that calculate localization results with received signal strength (RSS) mean samples, the proposed FNCC algorithm makes use of all the on-line RSS samples and reference point RSS variations to achieve higher fingerprinting accuracy. The FNCC computes efficiently while maintaining the same accuracy as the basic normalized cross correlation. Additionally, a KMF is also proposed to process fingerprinting localization results. It employs a new map matching algorithm to nonlinearize the linear location prediction process of Kalman filtering (KF) that takes advantage of spatial proximities of consecutive localization results. With a calibration model integrated into an indoor map, the map matching algorithm corrects unreasonable prediction locations of the KF according to the building interior structure. Thus, more accurate prediction locations are obtained. Using these locations, the KMF considerably improves fingerprinting algorithm performance. Experimental results demonstrate that the FNCC algorithm with reduced computational complexity outperforms other neighbor selection algorithms and the KMF effectively improves location sensing accuracy by using indoor map information and spatial proximities of consecutive localization results.

  8. Multimodal location estimation of videos and images

    CERN Document Server

    Friedland, Gerald

    2015-01-01

    This book presents an overview of the field of multimodal location estimation, i.e. using acoustic, visual, and/or textual cues to estimate the shown location of a video recording. The authors' sample research results in this field in a unified way integrating research work on this topic that focuses on different modalities, viewpoints, and applications. The book describes fundamental methods of acoustic, visual, textual, social graph, and metadata processing as well as multimodal integration methods used for location estimation. In addition, the text covers benchmark metrics and explores the limits of the technology based on a human baseline. ·         Discusses localization of multimedia data; ·         Examines fundamental methods of establishing location metadata for images and videos (other than GPS tagging); ·         Covers Data-Driven as well as Semantic Location Estimation.

  9. ATP, IMP, and glycogen in cod muscle at onset and during development of rigor mortis depend on the sampling location

    DEFF Research Database (Denmark)

    Cappeln, Gertrud; Jessen, Flemming

    2002-01-01

    Variation in glycogen, ATP, and IMP contents within individual cod muscles were studied in ice stored fish during the progress of rigor mortis. Rigor index was determined before muscle samples for chemical analyzes were taken at 16 different positions on the fish. During development of rigor......, the contents of glycogen and ATP decreased differently in relation to rigor index depending on sampling location. Although fish were considered to be in strong rigor according to the rigor index method, parts of the muscle were not in rigor as high ATP concentrations were found in dorsal and tall muscle....

  10. Summit crater lake observations, and the location, chemistry, and pH of water samples near Mount Chiginagak volcano, Alaska: 2004-2012

    Science.gov (United States)

    Schaefer, Janet R.; Scott, William E.; Evans, William C.; Wang, Bronwen; McGimsey, Robert G.

    2013-01-01

    maximum depth of 45 m (resulting pH ~2.9), and preventing the annual salmon run in the King Salmon River. A simultaneous release of gas and acidic aerosols from the crater caused widespread vegetation damage along the flow path. Since 2005, we have been monitoring the crater lake water that continues to flow into Mother Goose Lake by collecting surface water samples for major cation and anion analysis, measuring surface-water pH of affected drainages, and photo-documenting the condition of the summit crater lake. This report describes water sampling locations, provides a table of chemistry and pH measurements, and documents the condition of the summit crater between 2004 and 2011. In September 2013, the report was updated with results of water-chemistry samples collected in 2011 and 2012, which were added as an addendum.

  11. Results of Plutonium Intercalibration in Seawater and Seaweed Samples

    International Nuclear Information System (INIS)

    Fukai, R.; Murray, C.N.

    1976-01-01

    The results of the intercalibration exercise for the measurement of plutonium-239 and 228 in two seawater samples SW-I-1 and SW-I-2 and a marine algae sample AG-I-1 are presented. Seventeen laboratories from 8 countries as well as the IAEA International Laboratory of Marine Radioactivity took part. A discussion of the results and methods used in the analysis is given. It is concluded that in spite of the complicated chemical procedures involved in plutonium analysis, the scatter of the reported results was much smaller than that for fission product radionuclides such as strontium-90, ruthenium-106, cesium-137 etc. (author)

  12. Amchitka Island, Alaska, Biological Monitoring Report 2011 Sampling Results

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-09-01

    The Long-Term Surveillance and Maintenance (LTS&M) Plan for the U.S. Department of Energy (DOE) Office of Legacy Management (LM) Amchitka Island sites describes how LM plans to conduct its mission to protect human health and the environment at the three nuclear test sites located on Amchitka Island, Alaska. Amchitka Island, near the western end of the Aleutian Islands, is approximately 1,340 miles west-southwest of Anchorage, Alaska. Amchitka is part of the Aleutian Island Unit of the Alaska Maritime National Wildlife Refuge, which is administered by the U.S. Fish and Wildlife Service (USFWS). Since World War II, Amchitka has been used by multiple U.S. government agencies for various military and research activities. From 1943 to 1950, it was used as a forward air base for the U.S. Armed Forces. During the middle 1960s and early 1970s, the U.S. Department of Defense (DOD) and the U.S. Atomic Energy Commission (AEC) used a portion of the island as a site for underground nuclear tests. During the late 1980s and early 1990s, the U.S. Navy constructed and operated a radar station on the island. Three underground nuclear tests were conducted on Amchitka Island. DOD, in conjunction with AEC, conducted the first nuclear test (named Long Shot) in 1965 to provide data that would improve the United States' capability of detecting underground nuclear explosions. The second nuclear test (Milrow) was a weapons-related test conducted by AEC in 1969 as a means to study the feasibility of detonating a much larger device. Cannikin, the third nuclear test on Amchitka, was a weapons-related test detonated on November 6, 1971. With the exception of small concentrations of tritium detected in surface water shortly after the Long Shot test, radioactive fission products from the tests remain in the subsurface at each test location As a continuation of the environmental monitoring that has taken place on Amchitka Island since before 1965, LM in the summer of 2011 collected biological

  13. Historical review of long-term soil sampling for environmental surveillance at the Hanford Site and vicinity

    Energy Technology Data Exchange (ETDEWEB)

    Price, K.R.; Rickard, W.H.

    1997-08-01

    Soil samples have been collected routinely from the environs of the Hanford Site and analyzed since 1971. Correct interpretation of results depends on samples being collected from the same locations, the locations remaining relatively undisturbed, and collection and analytical procedures remaining the same or being equivalent. Historical files, documents, and annual environmental reports were reviewed to evaluate these factors. It was determined that 20 soil sampling locations, 11 onsite and 9 offsite, were established between 1971 and 1977 and represent long-term sampling locations. Sample collection and analytical procedures have remained essentially the same since 1971. The physical ecological attributes of each long-term soil sampling location were evaluated. During the review of historical records, a few results for 1970, 1971, and 1972 were noted as previously unreported in annual or special reports. These results are included in Appendix A. To complete the record, results previously reported in annual environmental reports are given in Appendix B. Global Positioning System (GPS) reading for 20 long-term soil sampling locations are provided in Appendix C.

  14. Historical review of long-term soil sampling for environmental surveillance at the Hanford Site and vicinity

    International Nuclear Information System (INIS)

    Price, K.R.; Rickard, W.H.

    1997-08-01

    Soil samples have been collected routinely from the environs of the Hanford Site and analyzed since 1971. Correct interpretation of results depends on samples being collected from the same locations, the locations remaining relatively undisturbed, and collection and analytical procedures remaining the same or being equivalent. Historical files, documents, and annual environmental reports were reviewed to evaluate these factors. It was determined that 20 soil sampling locations, 11 onsite and 9 offsite, were established between 1971 and 1977 and represent long-term sampling locations. Sample collection and analytical procedures have remained essentially the same since 1971. The physical ecological attributes of each long-term soil sampling location were evaluated. During the review of historical records, a few results for 1970, 1971, and 1972 were noted as previously unreported in annual or special reports. These results are included in Appendix A. To complete the record, results previously reported in annual environmental reports are given in Appendix B. Global Positioning System (GPS) reading for 20 long-term soil sampling locations are provided in Appendix C

  15. Water born pollutants sampling using porous suction samples

    International Nuclear Information System (INIS)

    Baig, M.A.

    1997-01-01

    The common standard method of sampling water born pollutants in the vadoze zone is core sampling and it is followed by extraction of pore fluid. This method does not allow sampling at the same location next time and again later on. There is an alternative approach for sampling fluids (water born pollutants) from both saturated and unsaturated regions of vadose zone using porous suction samplers. There are three types of porous suction samplers, vacuum-operated, pressure-vacuum lysimeters, high pressure vacuum samples. The suction samples are operated in the range of 0-70 centi bars and usually consist of ceramic and polytetrafluorethylene (PTFE). The operation range of PTFE is higher than ceramic cups. These samplers are well suited for in situ and repeated sampling form the same location. This paper discusses the physical properties and operating condition of such samplers to the utilized under our environmental sampling. (author)

  16. The effects of sampling location and turbulence on discharge estimates in short converging turbine intakes

    Energy Technology Data Exchange (ETDEWEB)

    Romero-Gomez, P.; Harding, S. F.; Richmond, M. C.

    2017-01-01

    Standards provide recommendations for best practices when installing current meters to measure fluid flow in closed conduits. A central guideline requires the velocity distribution to be regular and the flow steady. Because of the nature of the short converging intakes typical of low-head hydroturbines, these assumptions may be invalid if current meters are intended to be used to estimate discharge. Usual concerns are (1) the effects of the number of devices, (2) the sampling location and (3) the high turbulence caused by blockage from submersible traveling screens usually deployed for safe downstream fish passage. These three effects were examined in the present study by using 3D simulated flow fields in both steady-state and transient modes. In the process of describing an application at an existing hydroturbine intake at Ice Harbor Dam, the present work outlined the methods involved, which combined computational fluid dynamics, laboratory measurements in physical models of the hydroturbine, and current meter performance evaluations in experimental settings. The main conclusions in this specific application were that a steady-state flow field sufficed to determine the adequate number of meters and their location, and that both the transverse velocity and turbulence intensity had a small impact on estimate errors. However, while it may not be possible to extrapolate these findings to other field conditions and measuring devices, the study laid out a path to conduct similar assessments in other applications.

  17. Determination of the Number of Fixture Locating Points for Sheet Metal By Grey Model

    Directory of Open Access Journals (Sweden)

    Yang Bo

    2017-01-01

    Full Text Available In the process of the traditional fixture design for sheet metal part based on the "N-2-1" locating principle, the number of fixture locating points is determined by trial and error or the experience of the designer. To that end, a new design method based on grey theory is proposed to determine the number of sheet metal fixture locating points in this paper. Firstly, the training sample set is generated by Latin hypercube sampling (LHS and finite element analysis (FEA. Secondly, the GM(1, 1 grey model is constructed based on the established training sample set to approximate the mapping relationship between the number of fixture locating points and the concerned sheet metal maximum deformation. Thirdly, the final number of fixture locating points for sheet metal can be inversely calculated under the allowable maximum deformation. Finally, a sheet metal case is conducted and the results indicate that the proposed approach is effective and efficient in determining the number of fixture locating points for sheet metal.

  18. Quarterly sampling of the wetlands along the old F Area effluent ditch: August 1994

    International Nuclear Information System (INIS)

    Cummins, C.L.; Dixon, K.L.

    1994-08-01

    In August 1994, well point water and near-surface water samples were collected to characterize tritium and volatile organic compounds (VOC) in the wetlands along the old F-Area effluent ditch south of 643-E (old burial ground). The August sampling event was the third in a series of eight events. Groundwater flow paths suggest that compounds detected in water table wells around 643-E migrate towards the old F-Area effluent ditch and Fourmile Branch. Recent analytical results from well point and near-surface water sampling in the wetlands that comprise the old F-Area effluent ditch have shown that tritium and small quantities of VOCs are outcropping in the area. For this study, seven locations along the old F-Area effluent ditch were selected to be sampled. Well point samples were collected from all seven locations and near-surface water samples were collected at four locations. A secondary objective of this project was to compare VOC concentrations between the well points installed to depths of 6 to 8 ft and the near-surface water sampling buckets installed to depths of 1 to 2 ft. Based on differences in tritium concentrations at each location, it was determined that the sampling devices intercepted different groundwater flow paths. This negated direct comparison of analytical results between devices. However, when VOC concentrations measured at each well point and bucket location were normalized, based on the percent differences observed in tritium concentrations at that location, the resulting well point and bucket VOC concentrations were comparable in most cases. These results are consistent with the results from the three previous sampling events, and suggest that volatilization losses of VOCs from the buckets may be negligible. Since the results from the two sampling methodologies are not directly comparable, further sampling of the buckets is not planned

  19. Results of stainless steel canister corrosion studies and environmental sample investigations

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Charles R. [Sandia National Laboratories, Albuquerque, NM (United States); Enos, David [Sandia National Laboratories, Albuquerque, NM (United States)

    2014-12-01

    This progress report describes work being done at Sandia National Laboratories (SNL) to assess the localized corrosion performance of container/cask materials used in the interim storage of used nuclear fuel. The work involves both characterization of the potential physical and chemical environment on the surface of the storage canisters and how it might evolve through time, and testing to evaluate performance of the canister materials under anticipated storage conditions. To evaluate the potential environment on the surface of the canisters, SNL is working with the Electric Power Research Institute (EPRI) to collect and analyze dust samples from the surface of in-service SNF storage canisters. In FY 13, SNL analyzed samples from the Calvert Cliffs Independent Spent Fuel Storage Installation (ISFSI); here, results are presented for samples collected from two additional near-marine ISFSI sites, Hope Creek NJ, and Diablo Canyon CA. The Hope Creek site is located on the shores of the Delaware River within the tidal zone; the water is brackish and wave action is normally minor. The Diablo Canyon site is located on a rocky Pacific Ocean shoreline with breaking waves. Two types of samples were collected: SaltSmart™ samples, which leach the soluble salts from a known surface area of the canister, and dry pad samples, which collected a surface salt and dust using a swipe method with a mildly abrasive ScotchBrite™ pad. The dry samples were used to characterize the mineralogy and texture of the soluble and insoluble components in the dust via microanalytical techniques, including mapping X-ray Fluorescence spectroscopy and Scanning Electron Microscopy. For both Hope Creek and Diablo Canyon canisters, dust loadings were much higher on the flat upper surfaces of the canisters than on the vertical sides. Maximum dust sizes collected at both sites were slightly larger than 20 μm, but Phragmites grass seeds ~1 mm in size, were observed on the tops of the Hope Creek canisters

  20. Dark Energy Survey Year 1 Results: Galaxy Sample for BAO Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Crocce, M.; et al.

    2017-12-17

    We define and characterise a sample of 1.3 million galaxies extracted from the first year of Dark Energy Survey data, optimised to measure Baryon Acoustic Oscillations in the presence of significant redshift uncertainties. The sample is dominated by luminous red galaxies located at redshifts $z \\gtrsim 0.6$. We define the exact selection using color and magnitude cuts that balance the need of high number densities and small photometric redshift uncertainties, using the corresponding forecasted BAO distance error as a figure-of-merit in the process. The typical photo-$z$ uncertainty varies from $2.3\\%$ to $3.6\\%$ (in units of 1+$z$) from $z=0.6$ to $1$, with number densities from $200$ to $130$ galaxies per deg$^2$ in tomographic bins of width $\\Delta z = 0.1$. Next we summarise the validation of the photometric redshift estimation. We characterise and mitigate observational systematics including stellar contamination, and show that the clustering on large scales is robust in front of those contaminants. We show that the clustering signal in the auto-correlations and cross-correlations is generally consistent with theoretical models, which serves as an additional test of the redshift distributions.

  1. Locations of Sampling Stations for Water Quality Monitoring in Water Distribution Networks.

    Science.gov (United States)

    Rathi, Shweta; Gupta, Rajesh

    2014-04-01

    Water quality is required to be monitored in the water distribution networks (WDNs) at salient locations to assure the safe quality of water supplied to the consumers. Such monitoring stations (MSs) provide warning against any accidental contaminations. Various objectives like demand coverage, time for detection, volume of water contaminated before detection, extent of contamination, expected population affected prior to detection, detection likelihood and others, have been independently or jointly considered in determining optimal number and location of MSs in WDNs. "Demand coverage" defined as the percentage of network demand monitored by a particular monitoring station is a simple measure to locate MSs. Several methods based on formulation of coverage matrix using pre-specified coverage criteria and optimization have been suggested. Coverage criteria is defined as some minimum percentage of total flow received at the monitoring stations that passed through any upstream node included then as covered node of the monitoring station. Number of monitoring stations increases with the increase in the value of coverage criteria. Thus, the design of monitoring station becomes subjective. A simple methodology is proposed herein which priority wise iteratively selects MSs to achieve targeted demand coverage. The proposed methodology provided the same number and location of MSs for illustrative network as an optimization method did. Further, the proposed method is simple and avoids subjectivity that could arise from the consideration of coverage criteria. The application of methodology is also shown on a WDN of Dharampeth zone (Nagpur city WDN in Maharashtra, India) having 285 nodes and 367 pipes.

  2. Seismic Measurement of the Locations of the Base of Convection Zone and Helium Ionization Zone for Stars in the Kepler Seismic LEGACY Sample

    Energy Technology Data Exchange (ETDEWEB)

    Verma, Kuldeep; Lund, Mikkel N.; Aguirre, Víctor Silva [Stellar Astrophysics Centre, Department of Physics and Astronomy, Aarhus University, Ny Munkegade 120, DK-8000 Aarhus C (Denmark); Raodeo, Keyuri; Mazumdar, Anwesh [Homi Bhabha Centre for Science Education, TIFR, V. N. Purav Marg, Mankhurd, Mumbai 400088 (India); Antia, H. M. [Tata Institute of Fundamental Research, Homi Bhabha Road, Mumbai 400005 (India); Basu, Sarbani, E-mail: kuldeep@phys.au.dk [Astronomy Department, Yale University, P.O. Box 208101, New Haven, CT 065208101 (United States)

    2017-03-01

    Acoustic glitches are regions inside a star where the sound speed or its derivatives change abruptly. These leave a small characteristic oscillatory signature in the stellar oscillation frequencies. With the precision achieved by Kepler seismic data, it is now possible to extract these small amplitude oscillatory signatures, and infer the locations of the glitches. We perform glitch analysis for all the 66 stars in the Kepler seismic LEGACY sample to derive the locations of the base of the envelope convection zone (CZ) and the helium ionization zone. The signature from helium ionization zone is found to be robust for all stars in the sample, whereas the CZ signature is found to be weak and problematic, particularly for relatively massive stars with large errorbars on the oscillation frequencies. We demonstrate that the helium glitch signature can be used to constrain the properties of the helium ionization layers and the helium abundance.

  3. Analytical results from Tank 38H criticality Sample HTF-093

    International Nuclear Information System (INIS)

    Wilmarth, W.R.

    2000-01-01

    Resumption of processing in the 242-16H Evaporator could cause salt dissolution in the Waste Concentration Receipt Tank (Tank 38H). Therefore, High Level Waste personnel sampled the tank at the salt surface. Results of elemental analysis of the dried sludge solids from this sample (HTF-093) show significant quantities of neutron poisons (i.e., sodium, iron, and manganese) present to mitigate the potential for nuclear criticality. Comparison of this sample with the previous chemical and radiometric analyses of H-Area Evaporator samples show high poison to actinide ratios

  4. Stroke Location Is an Independent Predictor of Cognitive Outcome.

    Science.gov (United States)

    Munsch, Fanny; Sagnier, Sharmila; Asselineau, Julien; Bigourdan, Antoine; Guttmann, Charles R; Debruxelles, Sabrina; Poli, Mathilde; Renou, Pauline; Perez, Paul; Dousset, Vincent; Sibon, Igor; Tourdias, Thomas

    2016-01-01

    On top of functional outcome, accurate prediction of cognitive outcome for stroke patients is an unmet need with major implications for clinical management. We investigated whether stroke location may contribute independent prognostic value to multifactorial predictive models of functional and cognitive outcomes. Four hundred twenty-eight consecutive patients with ischemic stroke were prospectively assessed with magnetic resonance imaging at 24 to 72 hours and at 3 months for functional outcome using the modified Rankin Scale and cognitive outcome using the Montreal Cognitive Assessment (MoCA). Statistical maps of functional and cognitive eloquent regions were derived from the first 215 patients (development sample) using voxel-based lesion-symptom mapping. We used multivariate logistic regression models to study the influence of stroke location (number of eloquent voxels from voxel-based lesion-symptom mapping maps), age, initial National Institutes of Health Stroke Scale and stroke volume on modified Rankin Scale and MoCA. The second part of our cohort was used as an independent replication sample. In univariate analyses, stroke location, age, initial National Institutes of Health Stroke Scale, and stroke volume were all predictive of poor modified Rankin Scale and MoCA. In multivariable analyses, stroke location remained the strongest independent predictor of MoCA and significantly improved the prediction compared with using only age, initial National Institutes of Health Stroke Scale, and stroke volume (area under the curve increased from 0.697-0.771; difference=0.073; 95% confidence interval, 0.008-0.155). In contrast, stroke location did not persist as independent predictor of modified Rankin Scale that was mainly driven by initial National Institutes of Health Stroke Scale (area under the curve going from 0.840 to 0.835). Similar results were obtained in the replication sample. Stroke location is an independent predictor of cognitive outcome (MoCA) at 3

  5. Balanced sampling

    NARCIS (Netherlands)

    Brus, D.J.

    2015-01-01

    In balanced sampling a linear relation between the soil property of interest and one or more covariates with known means is exploited in selecting the sampling locations. Recent developments make this sampling design attractive for statistical soil surveys. This paper introduces balanced sampling

  6. Penile vascular diagnostic categorization using penile duplex Doppler ultrasound: Differences in vascular hemodynamics parameters by differences in anatomic sampling location

    Directory of Open Access Journals (Sweden)

    Fabio Pezzoni

    2016-10-01

    Full Text Available Objectives. In 2013 the International Society for Sexual Medicine(ISSM published the guidelines regarding the standard operating procedure (SOP for penile duplex Doppler ultrasound (PDDU. Although ISSM-SOP have given important strides in reducing interobserver variability in PDDU by procedural protocol and parameters these guidelines do not address the anatomic location along the penis at which hemodynamic measurements have to be done. In our opinion a “double sampling” may be interesting to detect the arteriogenic or venogenic nature of the erectile dysfunction (ED. In particular sampling measurements at the “crus” (at the level of the peno-scrotal junction may be significative for detection of veno-occlusive dysfunction (VOD,whereas an evaluation at “mid penis” (1/2 distance between peno-scrotal junction and coronal sulcus, may be useful to diagnose an arterial insufficiency (AI. Material and Methods. We evalued 90 men, mean age 56.3, affected with ED of medium degree, responder to PDE5-I that urdergone to PDDU and also responder after pharmacologic intracavernosal injection (PIIof prostaglandin E1 20 mcg, with rigid erection and normal maintenance. We moreover evalued 90 men in youthful age (mean 35.2, in absence of vascular risk factors, no responder to PDE5-I that undergone to PDDU by PII at high dosage (bimix: prostaglandin E1 20 mcg, papaverine 20 mg. Results. In the first pool the sampling at “mid penis” resulted significative for arterial insuffciency (AI in 81% (73, in presence of normal or borderline end diastolic velocity (EDV. Sampling at the “crus” resulted negative for VOD in 90% (81. In the second pool, 66.6% (60 resulted responder with rigid erection and normal maintenance in presence of normal hemodynamic parameters: peak systolic velocity (PSV and end diastolic velocity (EDV both at the “crus” and at “mid penis” sampling. 33.4% (30 responded with a semirigid erection and manifested a constant

  7. Comparison of the Multiple-sample means with composite sample results for fecal indicator bacteria by quantitative PCR and culture

    Science.gov (United States)

    ABSTRACT: Few studies have addressed the efficacy of composite sampling for measurement of indicator bacteria by QPCR. In this study, composite results were compared to single sample results for culture- and QPCR-based water quality monitoring. Composite results for both methods ...

  8. Exploring Technostress: Results of a Large Sample Factor Analysis

    OpenAIRE

    Jonušauskas, Steponas; Raišienė, Agota Giedrė

    2016-01-01

    With reference to the results of a large sample factor analysis, the article aims to propose the frame examining technostress in a population. The survey and principal component analysis of the sample consisting of 1013 individuals who use ICT in their everyday work was implemented in the research. 13 factors combine 68 questions and explain 59.13 per cent of the answers dispersion. Based on the factor analysis, questionnaire was reframed and prepared to reasonably analyze the respondents’ an...

  9. Comparison of total Hg results in sediment samples from Rio Grande reservoir determine by NAA and CV AAS

    International Nuclear Information System (INIS)

    Franklin, Robson L.

    2011-01-01

    The Rio Grande reservoir is located in the Metropolitan area of Sao Paulo and it is used for recreation purposes and as source water for drinking water production. During the last decades has been detected mercury contamination in the sediments of this reservoir, mainly in the eastern part, near the main affluent of the reservoir, in the Rio Grande da Serra and Ribeirao Pires counties. In the present study bottom sediment samples were collected in four different sites into four sampling campaigns during the period of September 2008 to January 2010. The samples were dried at room temperature, ground and passed through a 2 mm sieve. Total Hg determination in the sediment samples was carried out by two different analytical techniques: neutron activation analysis (NAA) and cold vapor atomic absorption spectrometry (CV AAS). The methodology validation, in terms of precision and accuracy, was performed by reference materials, and presented a recovery of 83 to 108%. The total Hg results obtained by both analytical techniques ranged from 3 to 71 mg kg-1 and were considered similar by statistical analysis, even though NAA technique furnishes the total concentration while CV AAS using the 3015 digestion procedure characterizes only the bioavailable Hg. These results confirm that both analytical techniques were suitable to detect the Hg concentration levels in the Rio Grande sediments studied. The Hg levels in the sediment of the Rio Grande reservoir confirm the anthropogenic origin for this element in this ecosystem. (author)

  10. An R package for spatial coverage sampling and random sampling from compact geographical strata by k-means

    NARCIS (Netherlands)

    Walvoort, D.J.J.; Brus, D.J.; Gruijter, de J.J.

    2010-01-01

    Both for mapping and for estimating spatial means of an environmental variable, the accuracy of the result will usually be increased by dispersing the sample locations so that they cover the study area as uniformly as possible. We developed a new R package for designing spatial coverage samples for

  11. Location in Mobile Networks Using Database Correlation (DCM

    Directory of Open Access Journals (Sweden)

    Michal Mada

    2008-01-01

    Full Text Available The article presents one of the methods of location (DCM, which is suitable for using in urban environments, where other methods are less accurate. The principle of this method is in comparison of measured samples of signal with samples stored in database. Next the article deals with methods for processing the data and other possibilities of correction of location.

  12. Location, location, location: Extracting location value from house prices

    OpenAIRE

    Kolbe, Jens; Schulz, Rainer; Wersing, Martin; Werwatz, Axel

    2012-01-01

    The price for a single-family house depends both on the characteristics of the building and on its location. We propose a novel semiparametric method to extract location values from house prices. After splitting house prices into building and land components, location values are estimated with adaptive weight smoothing. The adaptive estimator requires neither strong smoothness assumptions nor local symmetry. We apply the method to house transactions from Berlin, Germany. The estimated surface...

  13. Results of EDS uranium samples characterization after hydrogen loading

    International Nuclear Information System (INIS)

    Chicea, D.; Dash, J.

    2003-01-01

    Several experiments of loading natural uranium foils with hydrogen were done. Electrolysis was used for loading hydrogen into uranium, because it is the most efficient way for H loading. The composition of the surface and near surface of the samples was determined using an Oxford EDS spectrometer on a Scanning Electron Microscope, manufactured by ISI. Images were taken with several magnifications up to 3.4KX. Results reveal that when low current density was used, the surface patterns changed from granules on the surface having a typical size of 2-4 microns to pits under the surface having a typical size under one micron. When high current density was used the surface changed and presented deep fissures. The deep fissures are the result of the mechanical strain induced by the lattice expansion caused by hydrogen absorption. The surface composition was determined before and after hydrogen loading. Uranium, thorium platinum and carbon concentration were measured. Experiments suggest that the amount of thorium increases on the uranium sample with the total electric charge transported through electrolyte. Carbon concentration was found to decrease on the surface of the sample as the total electric charge transported through electrolyte increased. Platinum is used in electrolysis experiment as anode primarily because it does not dissolve in electrolyte and therefore it is not electro-deposited on the cathode surface. The results of the platinum concentration measurements on the surface of the samples we loaded with hydrogen reveal that the platinum concentration increased dramatically as the current density increased and that created platinum spots on the cathode surface. Work is in progress on the subject. (authors)

  14. Location-specific immunodetection of cocaine on banknotes.

    Science.gov (United States)

    van der Heide, Susan; Cunningham, Andrew; Hardwick, Sheila; Russell, David A

    2016-10-17

    A novel in-gel bioanalytical immunodetection method has been developed to determine both the presence and the location of cocaine on the surface of banknotes. The cocaine was 'fixed' to the surface of the banknote via a coating of a polyacrylamide gel matrix. Immunostaining of the immobilised cocaine on the banknote surface was performed using an anti-cocaine primary antibody, either pre-labelled with horse radish peroxidase (HRP) or in conjunction with a HRP-labelled secondary antibody. Visualisation of the location of the cocaine was achieved through chemiluminescence imaging of the banknote following application of a chemiluminescent substrate. The novel method was applied to the detection of cocaine on partial and whole banknote samples obtained from general circulation. Newly minted banknotes, with or without spiked cocaine, were used as positive and negative controls, respectively. The results obtained, for the first time, demonstrate the successful location-specific immunostaining of cocaine on banknotes. A preliminary analysis of six UK banknotes, obtained from general circulation, suggests that cocaine can be present at variable locations across the whole of the banknote.

  15. A patient's view on the location of the temporomandibular joint.

    Science.gov (United States)

    Koole, Paul; Zonnenberg, Adriaan J J; Mulder, Jan

    2018-03-25

    Objective A survey was held to establish whether laypeople knew the location of their temporomandibular joint. Methods A sample of 61 participants, visiting their dental office for a routine check-up, was given a three-question survey of whether they knew the location of their temporomandibular joint and could point to this location. Results Thirty-eight participants answered the question affirmatively. Only 13 pointed to the correct location. Of these, six participants received consultation for TMD in the past, three participants were healthcare providers, and four participants actually had knowledge of the exact location. Out of 23 participants who did not know the location, one accidently designated the correct position. Conclusion The location of the temporomandibular joint is not a well-known site for many patients. In the presence of orofacial pain, it seems advisable to let the patient designate and record the site of the pain on a drawing on the patient chart.

  16. Results of tritium measurement in environmental samples and drainage

    International Nuclear Information System (INIS)

    Koike, Ryoji; Hirai, Yasuo

    1983-01-01

    In Ibaraki prefecture, the tritium concentration in the drainage from the nuclear facilities has been measured since 1974. Then, with the start of operation of the fuel reprocessing plant in 1977, the tritium concentration in environmental samples was to be measured also in order to examine the effect of the drainage on the environment. The results of the tritium measurement in Ibaraki prefecture up to about 1980 are described: sampling points, sampling and measuring methods, the tritium concentration in the drainage, air, inland water and seawater, respectively. The drainages have been taken from Japan Atomic Power Company, Japan Atomic Energy Research Institute, and Power Reactor and Nuclear Fuel Development Corporation (with the fuel reprocessing plant). The samples of air, inland water and seawater have been taken in the areas concerned. The tritium concentration was measured by a low-background liquid scintillation counter. The measured values in the environment have been generally at low level, not different from other areas. (Mori, K.)

  17. Tank 214-AW-105, grab samples, analytical results for the final report

    International Nuclear Information System (INIS)

    Esch, R.A.

    1997-01-01

    This document is the final report for tank 241-AW-105 grab samples. Twenty grabs samples were collected from risers 10A and 15A on August 20 and 21, 1996, of which eight were designated for the K Basin sludge compatibility and mixing studies. This document presents the analytical results for the remaining twelve samples. Analyses were performed in accordance with the Compatibility Grab Sampling and Analysis Plan (TSAP) and the Data Quality Objectives for Tank Farms Waste Compatibility Program (DO). The results for the previous sampling of this tank were reported in WHC-SD-WM-DP-149, Rev. 0, 60-Day Waste Compatibility Safety Issue and Final Results for Tank 241-A W-105, Grab Samples 5A W-95-1, 5A W-95-2 and 5A W-95-3. Three supernate samples exceeded the TOC notification limit (30,000 microg C/g dry weight). Appropriate notifications were made. No immediate notifications were required for any other analyte. The TSAP requested analyses for polychlorinated biphenyls (PCB) for all liquids and centrifuged solid subsamples. The PCB analysis of the liquid samples has been delayed and will be presented in a revision to this document

  18. Effects of sample size and sampling frequency on studies of brown bear home ranges and habitat use

    Science.gov (United States)

    Arthur, Steve M.; Schwartz, Charles C.

    1999-01-01

    We equipped 9 brown bears (Ursus arctos) on the Kenai Peninsula, Alaska, with collars containing both conventional very-high-frequency (VHF) transmitters and global positioning system (GPS) receivers programmed to determine an animal's position at 5.75-hr intervals. We calculated minimum convex polygon (MCP) and fixed and adaptive kernel home ranges for randomly-selected subsets of the GPS data to examine the effects of sample size on accuracy and precision of home range estimates. We also compared results obtained by weekly aerial radiotracking versus more frequent GPS locations to test for biases in conventional radiotracking data. Home ranges based on the MCP were 20-606 km2 (x = 201) for aerial radiotracking data (n = 12-16 locations/bear) and 116-1,505 km2 (x = 522) for the complete GPS data sets (n = 245-466 locations/bear). Fixed kernel home ranges were 34-955 km2 (x = 224) for radiotracking data and 16-130 km2 (x = 60) for the GPS data. Differences between means for radiotracking and GPS data were due primarily to the larger samples provided by the GPS data. Means did not differ between radiotracking data and equivalent-sized subsets of GPS data (P > 0.10). For the MCP, home range area increased and variability decreased asymptotically with number of locations. For the kernel models, both area and variability decreased with increasing sample size. Simulations suggested that the MCP and kernel models required >60 and >80 locations, respectively, for estimates to be both accurate (change in area bears. Our results suggest that the usefulness of conventional radiotracking data may be limited by potential biases and variability due to small samples. Investigators that use home range estimates in statistical tests should consider the effects of variability of those estimates. Use of GPS-equipped collars can facilitate obtaining larger samples of unbiased data and improve accuracy and precision of home range estimates.

  19. Central location test vs. home use test: Contrasting results depending on product type

    NARCIS (Netherlands)

    Boutrolle, I.; Delarue, J.; Arranz, D.; Rogeaux, M.; Köster, E.P.

    2007-01-01

    Marketing professionals and sensory scientists have several hedonic testing methods at their disposal to assess product acceptability. The central location test (CLT) which usually takes place in a standardised location under controlled conditions is more frequently used than the home use test

  20. SEAMIST trademark soil sampling for tritiated water: First year's results

    International Nuclear Information System (INIS)

    Mallon, B.; Martins, S.A.; Houpis, J.L.; Lowry, W.; Cremer, C.D.

    1992-01-01

    SEAMIST trademark is a recently developed sampling system that enables one to measure various soil parameters by means of an inverted, removable, impermeable membrane tube inserted in a borehole. This membrane tube can have various measuring devices installed on it, such as gas ports, adsorbent pads, and electrical sensors. These membrane tubes are made of a laminated polymer. The Lawrence Livermore National Laboratory in Livermore, California, has installed two of these systems to monitor tritium in soil resulting from a leak in an underground storage tank. One tube is equipped with gas ports to sample soil vapor and the other with adsorbent pads to sample soil moisture. Borehole stability was maintained using either sand-filled or air-inflated tubes. Both system implementations yielded concentrations or activities that compared well with the measured concentrations of tritium in the soil taken during borehole construction. In addition, an analysis of the data suggest that both systems prevented the vertical migration of tritium in the boreholes. Also, a neutron probe was successfully used in a blank membrane inserted in one of the boreholes to monitor the moisture in the soil without exposing the probe to the tritium. The neutron log showed excellent agreement with the soil moisture content measured in soil samples taken during borehole construction. This paper describes the two SEAMIST trademark systems used and presents sampling results and comparisons

  1. Detailed characterization of welding fumes in personal exposure samples

    International Nuclear Information System (INIS)

    Quémerais, B; Mino, James; Amin, M R; Golshahi, H; Izadi, H

    2015-01-01

    The objective of the project was to develop a method allowing for detailed characterization of welding particles including particle number concentration, size distribution, surface chemistry and chemical composition of individual particles, as well as metal concentration of various welding fumes in personal exposure samples using regular sampling equipment. A sample strategy was developed to evaluate the variation of the collection methods on mass concentration. Samples were collected with various samplers and filters at two different locations using our collection system. The first location was using a robotic welding system while the second was manual welding. Collected samples were analysed for mass concentration using gravimetryand metal concentration using ICP/OES. More advanced analysis was performed on selected filters using X-Ray Photoelectron Spectroscopy to determine surface composition of the particles, and X-Ray Diffraction to determine chemical composition of the fumes. Results showed that the robotic system had a lot of variation in space when the collection system was located close to the weld. Collection efficiency was found to be quite variable depending upon the type of filter. As well, metal concentrations in blank filters were dependent upon the type of filter with MCE presenting with the highest blank values. Results obtained with the XRD and XPS systems showed that it was possible to analyse a small of powdered welding fume sample but results on filters were not conclusive. (paper)

  2. Zone-based RSS Reporting for Location Fingerprinting

    DEFF Research Database (Denmark)

    Kjærgaard, Mikkel Baun; Treu, Georg; Linnhoff–Popien, Claudia

    2007-01-01

    In typical location fingerprinting systems a tracked terminal reports sampled Received Signal Strength (RSS) values to a location server, which estimates its position based on a database of pre-recorded RSS fingerprints. So far, poll-based and periodic RSS reporting has been proposed. However......, for supporting proactive Location-based Services (LBSs), triggered by pre-defined spatial events, the periodic protocol is inefficient. Hence, this paper introduces zone-based RSS reporting: the location server translates geographical zones defined by the LBS into RSS-based representations, which are dynamically...

  3. Testing results of Monte Carlo sampling processes in MCSAD

    International Nuclear Information System (INIS)

    Pinnera, I.; Cruz, C.; Abreu, Y.; Leyva, A.; Correa, C.; Demydenko, C.

    2009-01-01

    The Monte Carlo Simulation of Atom Displacements (MCSAD) is a code implemented by the authors to simulate the complete process of atom displacement (AD) formation. This code makes use of the Monte Carlo (MC) method to sample all the processes involved in the gamma and electronic radiation transport through matter. The kernel of the calculations applied to this code relies on a model based on an algorithm developed by the authors, which firstly splits out multiple electron elastic scattering events from those single ones at higher scattering angles and then, from the last one, sampling those leading to AD at high transferred atomic recoil energies. Some tests have been developed to check the sampling algorithms with the help of the corresponding theoretical distribution functions. Satisfactory results have been obtained, which indicate the strength of the methods and subroutines used in the code. (Author)

  4. Quarterly sampling of the wetlands along the old F-Area effluent ditch, Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Dixon, K.L.; cummins, C.L.

    1994-05-01

    In May 1994, well point water and bucket samples were collected for tritium and volatile organic compounds in the wetlands along the old F-Area effluent ditch south of 643-E (old burial ground). The well point samples were collected from seven locations and the bucket samples from four locations. Results support that T and VOCs originating from 643-E are outcropping in the wetlands near this ditch. Based on differences in tritium contents at each location, it was determined that the sampling devices intercepted different groundwater flow paths; however, when VOCs were normalized, based on differences in T, resulting well point and bucket VOCs were comparable in most cases.

  5. Leak Location of Pipeline with Multibranch Based on a Cyber-Physical System

    Directory of Open Access Journals (Sweden)

    Xianming Lang

    2017-09-01

    Full Text Available Data cannot be shared and leakage cannot be located simultaneously among multiple pipeline leak detection systems. Based on cyber-physical system (CPS architecture, the method for locating leakage for pipelines with multibranch is proposed. The singular point of pressure signals at the ends of pipeline with multibranch is analyzed by wavelet packet analysis, so that the time feature samples could be established. Then, the Fischer-Burmeister function is introduced into the learning process of the twin support vector machine (TWSVM in order to avoid the matrix inversion calculation, and the samples are input into the improved twin support vector machine (ITWSVM to distinguish the pipeline leak location. The simulation results show that the proposed method is more effective than the back propagation (BP neural networks, the radial basis function (RBF neural networks, and the Lagrange twin support vector machine.

  6. Organic analysis of ambient samples collected near Tank 241-C-103: Results from samples collected on May 12, 1994

    International Nuclear Information System (INIS)

    Clauss, T.W.; Ligotke, M.W.; McVeety, B.D.; Lucke, R.B.; Young, J.S.; McCulloch, M.; Fruchter, J.S.; Goheen, S.C.

    1995-06-01

    This report describes organic analyses results from ambient samples collected both upwind and through the vapor sampling system (VSS) near Hanford waste storage Tank 241-C-103 (referred to as Tank C-103). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed. Quantitative results were obtained for organic compounds. Five organic tentatively identified compounds (TICS) were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and the reported concentrations are semiquantitative estimates. In addition, we looked for the 40 standard TO-14 analytes. We observed 39. Of these, only one was observed above the 2-ppbv calibrated instrument detection limit. Dichloromethane was above the detection limits using both methods, but the result from the TO-14 method is traceable to a standard gas mixture and is considered more accurate. Organic analytes were found only in the sample collected through the VSS, suggesting that these compounds were residual contamination from a previous sampling job. Detailed descriptions of the results appear in the text

  7. Estimation of AUC or Partial AUC under Test-Result-Dependent Sampling.

    Science.gov (United States)

    Wang, Xiaofei; Ma, Junling; George, Stephen; Zhou, Haibo

    2012-01-01

    The area under the ROC curve (AUC) and partial area under the ROC curve (pAUC) are summary measures used to assess the accuracy of a biomarker in discriminating true disease status. The standard sampling approach used in biomarker validation studies is often inefficient and costly, especially when ascertaining the true disease status is costly and invasive. To improve efficiency and reduce the cost of biomarker validation studies, we consider a test-result-dependent sampling (TDS) scheme, in which subject selection for determining the disease state is dependent on the result of a biomarker assay. We first estimate the test-result distribution using data arising from the TDS design. With the estimated empirical test-result distribution, we propose consistent nonparametric estimators for AUC and pAUC and establish the asymptotic properties of the proposed estimators. Simulation studies show that the proposed estimators have good finite sample properties and that the TDS design yields more efficient AUC and pAUC estimates than a simple random sampling (SRS) design. A data example based on an ongoing cancer clinical trial is provided to illustrate the TDS design and the proposed estimators. This work can find broad applications in design and analysis of biomarker validation studies.

  8. A comparison of results for samples collected with bailers constructed of different materials

    International Nuclear Information System (INIS)

    Thomey, N.; Ogle, R.; Jackson, J.

    1992-01-01

    A bailer is one of the most common sampling devices used to collect ground water samples. Bailers constructed from various materials are available; teflon, polyvinyl chloride (PVC), polyethylene, and stainless steel are all commonly used. It is widely recognized that sample results can be affected by the material from which the bailer is constructed. Teflon and stainless steel are usually recommended based upon their inert properties. The cost of these bailers is significantly higher than other types. For the purposes of petroleum storage tank investigations, sampling devices that would not compromise sample quality but be more economical than teflon or stainless steel would be especially desirable. Water samples were collected using the different types of bailers; teflon, stainless steel, PVC, and polyethylene. Split samples were analyzed for benzene, toluene, ethylbenzene, total xylenes, and Total Petroleum Hydrocarbons. The analytical results were compared to determine if differences were due to normal analytical variances or due to interaction of the sample with the sampling device. No difference was noted in the results which were obtained

  9. Phenolic Profiling and Antioxidant Capacity of Eugenia uniflora L. (Pitanga) Samples Collected in Different Uruguayan Locations.

    Science.gov (United States)

    Migues, Ignacio; Baenas, Nieves; Gironés-Vilaplana, Amadeo; Cesio, María Verónica; Heinzen, Horacio; Moreno, Diego A

    2018-04-24

    The use of nutrient-rich foods to enhance the wellness, health and lifestyle habits of consumers is globally encouraged. Native fruits are of great interest as they are grown and consumed locally and take part of the ethnobotanic knowledge of the population. Pitanga is an example of a native fruit from Uruguay, consumed as a jelly or an alcoholic beverage. Pitanga has a red-violet pigmentation, which is a common trait for foods that are a good source of antioxidants. Hence, fruits from different Uruguayan regions were analyzed via miniaturized sample preparation method, HPLC-DAD-ESI/MS n and RP-HPLC-DAD techniques to identify and quantify phenolic compounds, respectively. The antioxidant capacity was evaluated via DPPH and ORAC (Oxygen Radical Absorbance Capacity) assays. A multivariate linear regression was applied to correlate the observed antioxidant capacity with the phenolic content. Furthermore, Principal Components Analysis was performed to highlight characteristics between the various samples studied. The main results indicated differences between northern and southern Uruguayan samples. Delphinidin-3-hexoside was present in southern samples (mean of 293.16 µmol/100 g dry weight (DW)) and absent in the sample collected in the north (sample 3). All the samples contain high levels of cyanidin-3-hexoside, but a noticeable difference was found between the northern sample (150.45 µmol/100 g DW) and the southern sample (1121.98 µmol/100 g DW). The antioxidant capacity (mean ORAC of 56370 µmol Trolox ® /100 g DW) were high in all the samples compared to the Food and Drug Administration (FDA) database of similar berry-fruits. The results of this study highlight the nutraceutical value of a native fruit that has not been exploited until now.

  10. Phenolic Profiling and Antioxidant Capacity of Eugenia uniflora L. (Pitanga Samples Collected in Different Uruguayan Locations

    Directory of Open Access Journals (Sweden)

    Ignacio Migues

    2018-04-01

    Full Text Available The use of nutrient-rich foods to enhance the wellness, health and lifestyle habits of consumers is globally encouraged. Native fruits are of great interest as they are grown and consumed locally and take part of the ethnobotanic knowledge of the population. Pitanga is an example of a native fruit from Uruguay, consumed as a jelly or an alcoholic beverage. Pitanga has a red-violet pigmentation, which is a common trait for foods that are a good source of antioxidants. Hence, fruits from different Uruguayan regions were analyzed via miniaturized sample preparation method, HPLC-DAD-ESI/MSn and RP-HPLC-DAD techniques to identify and quantify phenolic compounds, respectively. The antioxidant capacity was evaluated via DPPH and ORAC (Oxygen Radical Absorbance Capacity assays. A multivariate linear regression was applied to correlate the observed antioxidant capacity with the phenolic content. Furthermore, Principal Components Analysis was performed to highlight characteristics between the various samples studied. The main results indicated differences between northern and southern Uruguayan samples. Delphinidin-3-hexoside was present in southern samples (mean of 293.16 µmol/100 g dry weight (DW and absent in the sample collected in the north (sample 3. All the samples contain high levels of cyanidin-3-hexoside, but a noticeable difference was found between the northern sample (150.45 µmol/100 g DW and the southern sample (1121.98 µmol/100 g DW. The antioxidant capacity (mean ORAC of 56370 µmol Trolox®/100 g DW were high in all the samples compared to the Food and Drug Administration (FDA database of similar berry-fruits. The results of this study highlight the nutraceutical value of a native fruit that has not been exploited until now.

  11. Source apportionment and location by selective wind sampling and Positive Matrix Factorization.

    Science.gov (United States)

    Venturini, Elisa; Vassura, Ivano; Raffo, Simona; Ferroni, Laura; Bernardi, Elena; Passarini, Fabrizio

    2014-10-01

    In order to determine the pollution sources in a suburban area and identify the main direction of their origin, PM2.5 was collected with samplers coupled with a wind select sensor and then subjected to Positive Matrix Factorization (PMF) analysis. In each sample, soluble ions, organic carbon, elemental carbon, levoglucosan, metals, and Polycyclic Aromatic Hydrocarbons (PAHs) were determined. PMF results identified six main sources affecting the area: natural gas home appliances, motor vehicles, regional transport, biomass combustion, manufacturing activities, and secondary aerosol. The connection of factor temporal trends with other parameters (i.e., temperature, PM2.5 concentration, and photochemical processes) confirms factor attributions. PMF analysis indicated that the main source of PM2.5 in the area is secondary aerosol. This should be mainly due to regional contributions, owing to both the secondary nature of the source itself and the higher concentration registered in inland air masses. The motor vehicle emission source contribution is also important. This source likely has a prevalent local origin. The most toxic determined components, i.e., PAHs, Cd, Pb, and Ni, are mainly due to vehicular traffic. Even if this is not the main source in the study area, it is the one of greatest concern. The application of PMF analysis to PM2.5 collected with this new sampling technique made it possible to obtain more detailed results on the sources affecting the area compared to a classical PMF analysis.

  12. Reference Device-Assisted Adaptive Location Fingerprinting

    Directory of Open Access Journals (Sweden)

    Dongjin Wu

    2016-06-01

    Full Text Available Location fingerprinting suffers in dynamic environments and needs recalibration from time to time to maintain system performance. This paper proposes an adaptive approach for location fingerprinting. Based on real-time received signal strength indicator (RSSI samples measured by a group of reference devices, the approach applies a modified Universal Kriging (UK interpolant to estimate adaptive temporal and environmental radio maps. The modified UK can take the spatial distribution characteristics of RSSI into account. In addition, the issue of device heterogeneity caused by multiple reference devices is further addressed. To compensate the measuring differences of heterogeneous reference devices, differential RSSI metric is employed. Extensive experiments were conducted in an indoor field and the results demonstrate that the proposed approach not only adapts to dynamic environments and the situation of changing APs’ positions, but it is also robust toward measuring differences of heterogeneous reference devices.

  13. Research results: preserving newborn blood samples.

    Science.gov (United States)

    Lewis, Michelle Huckaby; Scheurer, Michael E; Green, Robert C; McGuire, Amy L

    2012-11-07

    Retention and use, without explicit parental permission, of residual dried blood samples from newborn screening has generated public controversy over concerns about violations of family privacy rights and loss of parental autonomy. The public debate about this issue has included little discussion about the destruction of a potentially valuable public resource that can be used for research that may yield improvements in public health. The research community must advocate for policies and infrastructure that promote retention of residual dried blood samples and their use in biomedical research.

  14. 100 Area Columbia River sediment sampling

    International Nuclear Information System (INIS)

    Weiss, S.G.

    1993-01-01

    Forty-four sediment samples were collected from 28 locations in the Hanford Reach of the Columbia River to assess the presence of metals and man-made radionuclides in the near shore and shoreline settings of the Hanford Site. Three locations were sampled upriver of the Hanford Site plutonium production reactors. Twenty-two locations were sampled near the reactors. Three locations were sampled downstream of the reactors near the Hanford Townsite. Sediment was collected from depths of 0 to 6 in. and between 12 to 24 in. below the surface. Samples containing concentrations of metals exceeding the 95 % upper threshold limit values (DOE-RL 1993b) are considered contaminated. Contamination by arsenic, chromium, copper, lead, and zinc was found. Man-made radionuclides occur in all samples except four collected opposite the Hanford Townsite. Man-made radionuclide concentrations were generally less than 1 pCi/g

  15. 100 Area Columbia River sediment sampling

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, S.G. [Westinghouse Hanford Co., Richland, WA (United States)

    1993-09-08

    Forty-four sediment samples were collected from 28 locations in the Hanford Reach of the Columbia River to assess the presence of metals and man-made radionuclides in the near shore and shoreline settings of the Hanford Site. Three locations were sampled upriver of the Hanford Site plutonium production reactors. Twenty-two locations were sampled near the reactors. Three locations were sampled downstream of the reactors near the Hanford Townsite. Sediment was collected from depths of 0 to 6 in. and between 12 to 24 in. below the surface. Samples containing concentrations of metals exceeding the 95 % upper threshold limit values (DOE-RL 1993b) are considered contaminated. Contamination by arsenic, chromium, copper, lead, and zinc was found. Man-made radionuclides occur in all samples except four collected opposite the Hanford Townsite. Man-made radionuclide concentrations were generally less than 1 pCi/g.

  16. Protein (multi-)location prediction: using location inter-dependencies in a probabilistic framework

    Science.gov (United States)

    2014-01-01

    Motivation Knowing the location of a protein within the cell is important for understanding its function, role in biological processes, and potential use as a drug target. Much progress has been made in developing computational methods that predict single locations for proteins. Most such methods are based on the over-simplifying assumption that proteins localize to a single location. However, it has been shown that proteins localize to multiple locations. While a few recent systems attempt to predict multiple locations of proteins, their performance leaves much room for improvement. Moreover, they typically treat locations as independent and do not attempt to utilize possible inter-dependencies among locations. Our hypothesis is that directly incorporating inter-dependencies among locations into both the classifier-learning and the prediction process can improve location prediction performance. Results We present a new method and a preliminary system we have developed that directly incorporates inter-dependencies among locations into the location-prediction process of multiply-localized proteins. Our method is based on a collection of Bayesian network classifiers, where each classifier is used to predict a single location. Learning the structure of each Bayesian network classifier takes into account inter-dependencies among locations, and the prediction process uses estimates involving multiple locations. We evaluate our system on a dataset of single- and multi-localized proteins (the most comprehensive protein multi-localization dataset currently available, derived from the DBMLoc dataset). Our results, obtained by incorporating inter-dependencies, are significantly higher than those obtained by classifiers that do not use inter-dependencies. The performance of our system on multi-localized proteins is comparable to a top performing system (YLoc+), without being restricted only to location-combinations present in the training set. PMID:24646119

  17. SAMPLE RESULTS FROM THE INTEGRATED SALT DISPOSITION PROGRAM MACROBATCH 5 TANK 21H QUALIFICATION MST, ESS AND PODD SAMPLES

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T.; Fink, S.

    2012-04-24

    Savannah River National Laboratory (SRNL) performed experiments on qualification material for use in the Integrated Salt Disposition Program (ISDP) Batch 5 processing. This qualification material was a composite created from recent samples from Tank 21H and archived samples from Tank 49H to match the projected blend from these two tanks. Additionally, samples of the composite were used in the Actinide Removal Process (ARP) and extraction-scrub-strip (ESS) tests. ARP and ESS test results met expectations. A sample from Tank 21H was also analyzed for the Performance Objectives Demonstration Document (PODD) requirements. SRNL was able to meet all of the requirements, including the desired detection limits for all the PODD analytes. This report details the results of the Actinide Removal Process (ARP), Extraction-Scrub-Strip (ESS) and Performance Objectives Demonstration Document (PODD) samples of Macrobatch (Salt Batch) 5 of the Integrated Salt Disposition Program (ISDP).

  18. Store Location in Shopping Centers: Theory & Estimates

    OpenAIRE

    Kerry D. Vandell; Charles C. Carter

    2000-01-01

    This paper develops a formal theory of store location within shopping centers based on bid rent theory. The bid rent model is fully speci?ed and solved with the objective function of pro?t maximization in the presence of comparative, multipurpose and impulse shopping behavior. Several hypotheses result about the optimal relationships between store types, sizes, rents, sales, and distances from the mall center. The hypotheses are tested and con?rmed using data from a sample of 689 leases in ei...

  19. Evaluation of analytical results on DOE Quality Assessment Program Samples

    International Nuclear Information System (INIS)

    Jaquish, R.E.; Kinnison, R.R.; Mathur, S.P.; Sastry, R.

    1985-01-01

    Criteria were developed for evaluating the participants analytical results in the DOE Quality Assessment Program (QAP). Historical data from previous QAP studies were analyzed using descriptive statistical methods to determine the interlaboratory precision that had been attained. Performance criteria used in other similar programs were also reviewed. Using these data, precision values and control limits were recommended for each type of analysis performed in the QA program. Results of the analysis performed by the QAP participants on the November 1983 samples were statistically analyzed and evaluated. The Environmental Measurements Laboratory (EML) values were used as the known values and 3-sigma precision values were used as control limits. Results were submitted by 26 participating laboratories for 49 different radionuclide media combinations. The participants reported 419 results and of these, 350 or 84% were within control limits. Special attention was given to the data from gamma spectral analysis of air filters and water samples. both normal probability and box plots were prepared for each nuclide to help evaluate the distribution of the data. Results that were outside the expected range were identified and suggestions made that laboratories check calculations, and procedures on these results

  20. Automated seismic waveform location using Multichannel Coherency Migration (MCM)-I. Theory

    Science.gov (United States)

    Shi, Peidong; Angus, Doug; Rost, Sebastian; Nowacki, Andy; Yuan, Sanyi

    2018-03-01

    With the proliferation of dense seismic networks sampling the full seismic wavefield, recorded seismic data volumes are getting bigger and automated analysis tools to locate seismic events are essential. Here, we propose a novel Multichannel Coherency Migration (MCM) method to locate earthquakes in continuous seismic data and reveal the location and origin time of seismic events directly from recorded waveforms. By continuously calculating the coherency between waveforms from different receiver pairs, MCM greatly expands the available information which can be used for event location. MCM does not require phase picking or phase identification, which allows fully automated waveform analysis. By migrating the coherency between waveforms, MCM leads to improved source energy focusing. We have tested and compared MCM to other migration-based methods in noise-free and noisy synthetic data. The tests and analysis show that MCM is noise resistant and can achieve more accurate results compared with other migration-based methods. MCM is able to suppress strong interference from other seismic sources occurring at a similar time and location. It can be used with arbitrary 3D velocity models and is able to obtain reasonable location results with smooth but inaccurate velocity models. MCM exhibits excellent location performance and can be easily parallelized giving it large potential to be developed as a real-time location method for very large datasets.

  1. Performance test of SAUNA xenon mobile sampling system

    International Nuclear Information System (INIS)

    Hu Dan; Yang Bin; Yang Weigeng; Jia Huaimao; Wang Shilian; Li Qi; Zhao Yungang; Fan Yuanqing; Chen Zhanying; Chang Yinzhong; Liu Shujiang; Zhang Xinjun; Wang Jun

    2011-01-01

    In this article, the structure and basic functions of SAUNA noble gas xenon mobile sampling system are introduced. The sampling capability of this system is about 2.2 mL per day, as a result from a 684-h operation. The system can be transported to designated locations conveniently to collect xenon sample for routine or emergency environment monitoring. (authors)

  2. Validation of Passive Sampling Devices for Monitoring of Munitions Constituents in Underwater Environments

    Science.gov (United States)

    2017-09-01

    and sampling handling was met. All calibration criteria and instrument maintenance was met for all final reported data. 23 3.2 QUALITATIVE ...the relatively large size of each sampling box within the grid, there were no issues associated with locating appropriate anchoring locations, based...quantiative, as only estimated sampling rates were available, or spiked recoveries were lower suggesting the results are qualitative . TNT RDX ADNTs

  3. Water Sample Points, Navajo Nation, 2000, USACE

    Data.gov (United States)

    U.S. Environmental Protection Agency — This point shapefile presents the locations and results for water samples collected on the Navajo Nation by the US Army Corps of Engineers (USACE) for the US...

  4. Sample Processor for Life on Icy Worlds (SPLIce): Design and Test Results

    Science.gov (United States)

    Chinn, Tori N.; Lee, Anthony K.; Boone, Travis D.; Tan, Ming X.; Chin, Matthew M.; McCutcheon, Griffin C.; Horne, Mera F.; Padgen, Michael R.; Blaich, Justin T.; Forgione, Joshua B.; hide

    2017-01-01

    We report the design, development, and testing of the Sample Processor for Life on Icy Worlds (SPLIce) system, a microfluidic sample processor to enable autonomous detection of signatures of life and measurements of habitability parameters in Ocean Worlds. This monolithic fluid processing-and-handling system (Figure 1; mass 0.5 kg) retrieves a 50-L-volume sample and prepares it to supply a suite of detection instruments, each with unique preparation needs. SPLIce has potential applications in orbiter missions that sample ocean plumes, such as found in Saturns icy moon Enceladus, or landed missions on the surface of icy satellites, such as Jupiters moon Europa. Answering the question Are we alone in the universe? is captivating and exceptionally challenging. Even general criteria that define life very broadly include a significant role for water [1,2]. Searches for extinct or extant life therefore prioritize locations of abundant water whether in ancient (Mars), or present (Europa and Enceladus) times. Only two previous planetary missions had onboard fluid processing: the Viking Biology Experiments [3] and Phoenixs Wet Chemistry Laboratory (WCL) [4]. SPLIce differs crucially from those systems, including its capability to process and distribute L-volume samples and the integration autonomous control of a wide range of fluidic functions, including: 1) retrieval of fluid samples from an evacuated sample chamber; 2) onboard multi-year storage of dehydrated reagents; 3) integrated pressure, pH, and conductivity measurement; 4) filtration and retention of insoluble particles for microscopy; 5) dilution or vacuum-driven concentration of samples to accommodate instrument working ranges; 6) removal of gas bubbles from sample aliquots; 7) unidirectional flow (check valves); 8) active flow-path selection (solenoid-actuated valves); 9) metered pumping in 100 nL volume increments. The SPLIce manifold, made of three thermally fused layers of precision-machined cyclo

  5. The Apollo lunar samples collection analysis and results

    CERN Document Server

    Young, Anthony

    2017-01-01

    This book focuses on the specific mission planning for lunar sample collection, the equipment used, and the analysis and findings concerning the samples at the Lunar Receiving Laboratory in Texas. Anthony Young documents the collection of Apollo samples for the first time for readers of all backgrounds, and includes interviews with many of those involved in planning and analyzing the samples. NASA contracted with the U.S. Geologic Survey to perform classroom and field training of the Apollo astronauts. NASA’s Geology Group within the Manned Spacecraft Center in Houston, Texas, helped to establish the goals of sample collection, as well as the design of sample collection tools, bags, and storage containers. In this book, detailed descriptions are given on the design of the lunar sampling tools, the Modular Experiment Transporter used on Apollo 14, and the specific areas of the Lunar Rover vehicle used for the Apollo 15, 16, and 17 missions, which carried the sampling tools, bags, and other related equipment ...

  6. Exploring Technostress: Results of a Large Sample Factor Analysis

    Directory of Open Access Journals (Sweden)

    Steponas Jonušauskas

    2016-06-01

    Full Text Available With reference to the results of a large sample factor analysis, the article aims to propose the frame examining technostress in a population. The survey and principal component analysis of the sample consisting of 1013 individuals who use ICT in their everyday work was implemented in the research. 13 factors combine 68 questions and explain 59.13 per cent of the answers dispersion. Based on the factor analysis, questionnaire was reframed and prepared to reasonably analyze the respondents’ answers, revealing technostress causes and consequences as well as technostress prevalence in the population in a statistically validated pattern. A key elements of technostress based on factor analysis can serve for the construction of technostress measurement scales in further research.

  7. Household location choices: implications for biodiversity conservation.

    Science.gov (United States)

    Peterson, M Nils; Chen, Xiaodong; Liu, Jianguo

    2008-08-01

    Successful conservation efforts require understanding human behaviors that directly affect biodiversity. Choice of household location represents an observable behavior that has direct effects on biodiversity conservation, but no one has examined the sociocultural predictors of this choice relative to its environmental impacts. We conducted a case study of the Teton Valley of Idaho and Wyoming (U.S.A.) that (1) explored relationships between sociodemographic variables, environmental attitudes, and the environmental impact of household location choices, (2) assessed the potential for small household sizes in natural areas to multiply the environmental impacts of household location decisions, and (3) evaluated how length of residency predicted the environmental attitudes of people living in natural areas. We collected sociodemographic data, spatial coordinates, and land-cover information in a survey of 416 households drawn from a random sample of Teton Valley residents (95% compliance rate). Immigrants (respondents not born in the study area) with the lowest education levels and least environmentally oriented attitudes lived in previously established residential areas in disproportionately high numbers, and older and more educated immigrants with the most environmentally oriented attitudes lived in natural areas in disproportionately high numbers. Income was not a significant predictor of household location decisions. Those living in natural areas had more environmental impact per person because of the location and because small households (educated, and potentially growing more environmentally oriented, these patterns are troubling for biodiversity conservation. Our results demonstrate a need for environmentalists to make household location decisions that reflect their environmental attitudes and future research to address how interactions between education level, environmental attitudes, population aging, and household location choices influence biodiversity

  8. Testing aggregation hypotheses among Neotropical trees and shrubs: results from a 50-ha plot over 20 years of sampling.

    Science.gov (United States)

    Myster, Randall W; Malahy, Michael P

    2012-09-01

    Spatial patterns of tropical trees and shrubs are important to understanding their interaction and the resultant structure of tropical rainforests. To assess this issue, we took advantage of previously collected data, on Neotropical tree and shrub stem identified to species and mapped for spatial coordinates in a 50ha plot, with a frequency of every five years and over a 20 year period. These stems data were first placed into four groups, regardless of species, depending on their location in the vertical strata of the rainforest (shrubs, understory trees, mid-sized trees, tall trees) and then used to generate aggregation patterns for each sampling year. We found shrubs and understory trees clumped at small spatial scales of a few meters for several of the years sampled. Alternatively, mid-sized trees and tall trees did not clump, nor did they show uniform (regular) patterns, during any sampling period. In general (1) groups found higher in the canopy did not show aggregation on the ground and (2) the spatial patterns of all four groups showed similarity among different sampling years, thereby supporting a "shifting mosaic" view of plant communities over large areas. Spatial analysis, such as this one, are critical to understanding and predicting tree spaces, tree-tree replacements and the Neotropical forest patterns, such as biodiversity and those needed for sustainability efforts, they produce.

  9. Lake Beach Monitoring Locations in Iowa

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Monitored state lake beach locations in Iowa. The Watershed Monitoring & Assessment Section of the Iowa DNR takes regular water samples at these listed beaches...

  10. Iowa Geologic Sampling Points

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Point locations of geologic samples/files in the IGS repository. Types of samples include well cuttings, outcrop samples, cores, drillers logs, measured sections,...

  11. Fast randomized point location without preprocessing in two- and three-dimensional Delaunay triangulations

    Energy Technology Data Exchange (ETDEWEB)

    Muecke, E.P.; Saias, I.; Zhu, B.

    1996-05-01

    This paper studies the point location problem in Delaunay triangulations without preprocessing and additional storage. The proposed procedure finds the query point simply by walking through the triangulation, after selecting a good starting point by random sampling. The analysis generalizes and extends a recent result of d = 2 dimensions by proving this procedure to take expected time close to O(n{sup 1/(d+1)}) for point location in Delaunay triangulations of n random points in d = 3 dimensions. Empirical results in both two and three dimensions show that this procedure is efficient in practice.

  12. Location of colorectal cancer: colonoscopy versus surgery. Yield of colonoscopy in predicting actual location.

    Science.gov (United States)

    Blum-Guzman, Juan Pablo; Wanderley de Melo, Silvio

    2017-07-01

     Recent studies suggest that differences in biological characteristics and risk factors across cancer site within the colon and rectum may translate to differences in survival. It can be challenging at times to determine the precise anatomical location of a lesion with a luminal view during colonoscopy. The aim of this study is to determine if there is a significant difference between the location of colorectal cancers described by gastroenterologists in colonoscopies and the actual anatomical location noted on operative and pathology reports after colon surgery.  A single-center retrospective analysis of colonoscopies of patient with reported colonic masses from January 2005 to April 2014 (n = 380) was carried. Assessed data included demography, operative and pathology reports. Findings were compared: between the location of colorectal cancers described by gastroenterologists in colonoscopies and the actual anatomical location noted on operative reports or pathology samples.  We identified 380 colonic masses, 158 were confirmed adenocarcinomas. Of these 123 underwent surgical resection, 27 had to be excluded since no specific location was reported on their operative or pathology report. An absolute difference between endoscopic and surgical location was found in 32 cases (33 %). Of these, 22 (23 %) differed by 1 colonic segment, 8 (8 %) differed by 2 colonic segments and 2 (2 %) differed by 3 colonic segments.  There is a significant difference between the location of colorectal cancers reported by gastroenterologists during endoscopy and the actual anatomical location noted on operative or pathology reports after colon surgery. Endoscopic tattooing should be used when faced with any luminal lesions of interest.

  13. What does visual suffix interference tell us about spatial location in working memory?

    Science.gov (United States)

    Allen, Richard J; Castellà, Judit; Ueno, Taiji; Hitch, Graham J; Baddeley, Alan D

    2015-01-01

    A visual object can be conceived of as comprising a number of features bound together by their joint spatial location. We investigate the question of whether the spatial location is automatically bound to the features or whether the two are separable, using a previously developed paradigm whereby memory is disrupted by a visual suffix. Participants were shown a sample array of four colored shapes, followed by a postcue indicating the target for recall. On randomly intermixed trials, a to-be-ignored suffix array consisting of two different colored shapes was presented between the sample and the postcue. In a random half of suffix trials, one of the suffix items overlaid the location of the target. If location was automatically encoded, one might expect the colocation of target and suffix to differentially impair performance. We carried out three experiments, cuing for recall by spatial location (Experiment 1), color or shape (Experiment 2), or both randomly intermixed (Experiment 3). All three studies showed clear suffix effects, but the colocation of target and suffix was differentially disruptive only when a spatial cue was used. The results suggest that purely visual shape-color binding can be retained and accessed without requiring information about spatial location, even when task demands encourage the encoding of location, consistent with the idea of an abstract and flexible visual working memory system.

  14. Deepwater Horizon MC252 deepwater benthic communities data from the Environmental Response Management Application (ERMA) containing sediment toxicity sample results and total polycyclic aromatic hydrocarbon (TPAH) results, habitat injury zones, mesophotic coral reef resources, and related deep-sea area injury toxicity results collected from samples taken from 2010-09-16 to 2011-12-04 in the Northern Gulf of Mexico (NCEI Accession 0163817)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This Archival Information Package (AIP) contains Environmental Resource Management Application (ERMA) GIS layers that represent sample locations for workplan...

  15. Results of the Characterization and Dissolution Tests of Samples from Tank 16H

    International Nuclear Information System (INIS)

    Hay, M.S.

    1999-01-01

    Samples from Tank 16H annulus and one sample from the tank interior were characterized to provide a source term for use in fate and transport modeling. Four of the annulus samples appeared to be similar based on visual examination and were combined to form a composite. One of the annulus samples appeared to be different from the other four based on visual examination and was analyzed separately. The analytical results of the tank interior sample indicate the sample is composed predominantly of iron containing compounds. Both of the annulus samples are composed mainly of sodium salts, however, the composite sample contained significantly more sludge/sand material of low solubilitity. The characterization of the tank 16H annulus and tank interior samples was hampered by the high dose rate and the nature of the samples. The difficulties resulted in large uncertainties in the analytical data. The large uncertainties coupled with the number of important species below detection limits indicate the need for reanalysis of the Tank 16H samples as funding becomes available. Recommendations on potential remedies for these difficulties are provided. In general, none of the reagents appeared to be effective in dissolving the composite sample even after two contacts at elevated temperature. In contrast to the composite sample, all of the reagents dissolved a large percentage of the HTF-087 solids after two contacts at ambient temperature

  16. Expectation-Maximization Tensor Factorization for Practical Location Privacy Attacks

    Directory of Open Access Journals (Sweden)

    Murakami Takao

    2017-10-01

    Full Text Available Location privacy attacks based on a Markov chain model have been widely studied to de-anonymize or de-obfuscate mobility traces. An adversary can perform various kinds of location privacy attacks using a personalized transition matrix, which is trained for each target user. However, the amount of training data available to the adversary can be very small, since many users do not disclose much location information in their daily lives. In addition, many locations can be missing from the training traces, since many users do not disclose their locations continuously but rather sporadically. In this paper, we show that the Markov chain model can be a threat even in this realistic situation. Specifically, we focus on a training phase (i.e. mobility profile building phase and propose Expectation-Maximization Tensor Factorization (EMTF, which alternates between computing a distribution of missing locations (E-step and computing personalized transition matrices via tensor factorization (M-step. Since the time complexity of EMTF is exponential in the number of missing locations, we propose two approximate learning methods, one of which uses the Viterbi algorithm while the other uses the Forward Filtering Backward Sampling (FFBS algorithm. We apply our learning methods to a de-anonymization attack and a localization attack, and evaluate them using three real datasets. The results show that our learning methods significantly outperform a random guess, even when there is only one training trace composed of 10 locations per user, and each location is missing with probability 80% (i.e. even when users hardly disclose two temporally-continuous locations.

  17. Results of elemental analyses of water and waterborne sediment samples from the Fairbanks NTMS quadrangle, Alaska

    International Nuclear Information System (INIS)

    Sharp, R.R. Jr.; Aamodt, P.L; Hill, D.E.

    1979-04-01

    During the late spring and then again in late summer, 1977, lake and stream water and bottom sediment samples were collected at a nominal density of one location every 16 km 2 from throughout the approximate 16,500-km 2 area of the Fairbanks NTMS quadrangle, Alaska. These samples were collected using standard procedures by investigators from the University of Alaska, Fairbanks, as part of a special Hydrogeochemical and Stream Sediment Reconnaissance (HSSR) study to identify variance in total uranium contents related to natural factors such as seasonal changes, source types, and geologic/geographic environments. Histograms and statistical summaries of total uranium in a number of sample populations presented herein indicate that water samples collected in late summer have a mean uranium content that is slightly higher than the mean for waters collected in the spring. Dilution and/or evaporative concentration are possible causes for this difference. Sediment samples collected from streams and springs have a slightly higher mean uranium content than those collected from lakes, and this is consistent with HSSR data from other Alaskan areas. The Alaskan investigators will complete a detailed analysis of variance study of these data in the near future and a second open-file report will be forthcoming upon its completion

  18. Analytical results and sample locality map for rock, stream-sediment, and soil samples, Northern and Eastern Coloado Desert BLM Resource Area, Imperial, Riverside, and San Bernardino Counties, California

    Science.gov (United States)

    King, Harley D.; Chaffee, Maurice A.

    2000-01-01

    Desert BLM Resource Area and vicinity. Included in the 1,245 stream-sediment samples collected by the USGS are 284 samples collected as part of the current study, 817 samples collected as part of investigations of the12 BLM WSAs and re-analyzed for the present study, 45 samples from the Needles 1? X 2? quadrangle, and 99 samples from the El Centro 1? X 2? quadrangle. The NURE stream-sediment and soil samples were re-analyzed as part of the USGS study in the Needles quadrangle. Analytical data for samples from the Chocolate Mountain Aerial Gunnery Range, which is located within the area of the NECD, were previously reported (King and Chaffee, 1999a). For completeness, these results are also included in this report. Analytical data for samples from the area of Joshua Tree National Park that is within the NECD have also been reported (King and Chaffee, 1999b). These results are not included in this report. The analytical data presented here can be used for baseline geochemical, mineral resource, and environmental geochemical studies.

  19. Visual Sample Plan (VSP) - FIELDS Integration

    Energy Technology Data Exchange (ETDEWEB)

    Pulsipher, Brent A.; Wilson, John E.; Gilbert, Richard O.; Hassig, Nancy L.; Carlson, Deborah K.; Bing-Canar, John; Cooper, Brian; Roth, Chuck

    2003-04-19

    Two software packages, VSP 2.1 and FIELDS 3.5, are being used by environmental scientists to plan the number and type of samples required to meet project objectives, display those samples on maps, query a database of past sample results, produce spatial models of the data, and analyze the data in order to arrive at defensible decisions. VSP 2.0 is an interactive tool to calculate optimal sample size and optimal sample location based on user goals, risk tolerance, and variability in the environment and in lab methods. FIELDS 3.0 is a set of tools to explore the sample results in a variety of ways to make defensible decisions with quantified levels of risk and uncertainty. However, FIELDS 3.0 has a small sample design module. VSP 2.0, on the other hand, has over 20 sampling goals, allowing the user to input site-specific assumptions such as non-normality of sample results, separate variability between field and laboratory measurements, make two-sample comparisons, perform confidence interval estimation, use sequential search sampling methods, and much more. Over 1,000 copies of VSP are in use today. FIELDS is used in nine of the ten U.S. EPA regions, by state regulatory agencies, and most recently by several international countries. Both software packages have been peer-reviewed, enjoy broad usage, and have been accepted by regulatory agencies as well as site project managers as key tools to help collect data and make environmental cleanup decisions. Recently, the two software packages were integrated, allowing the user to take advantage of the many design options of VSP, and the analysis and modeling options of FIELDS. The transition between the two is simple for the user – VSP can be called from within FIELDS, automatically passing a map to VSP and automatically retrieving sample locations and design information when the user returns to FIELDS. This paper will describe the integration, give a demonstration of the integrated package, and give users download

  20. Methodologies to assess PWSCC susceptibility of primary component Alloy 600 locations in pressurized water reactors

    International Nuclear Information System (INIS)

    Rao, G.V.

    1993-01-01

    Methodologies to assess susceptibility to Primary Water Stress Corrosion Cracking (PWSCC) of Alloy 600 component locations in the Primary System of Pressurized Water Reactors are presented. The assessment methodologies are presented. The assessment methodologies are based on Relative Susceptibility Index (RSI) and Cumulative Susceptibility Index (CSI) models utilizing key contributing parameters such as service and residual stresses, yield strength, service temperature, material condition and microstructure, and the accumulated service time. To aid in the development of future inspection plans, a method of ranking of the assessed susceptibilities by 'bench marking' with respect to the susceptibility of a reference location of known PWSCC history of a reference location of known PWSCC history is presented. Means of utilizing the susceptibility ranking results in developing a prioritized inspection plan are discussed. A follow-up investigative plan to the initial inspection is proposed, which includes identification of critical sampling locations, sample extraction, sample investigations and testing to ensure that the potentially highest susceptibility locations are free from near term PWSCC and, further, to provide a basis for established schedules for future inspections. Finally, parametric considerations of the contributing factor are presented to help the utility choose suitable option to mitigate the PWSCC issue while minimizing the impact on continued service

  1. Mass counting of radioactivity samples

    International Nuclear Information System (INIS)

    Oesterlin, D.L.; Obrycki, R.F.

    1977-01-01

    A method and apparatus for concurrently counting a plurality of radioactive samples is claimed. The position sensitive circuitry of a scintillation camera is employed to sort electrical pulses resulting from scintillations according to the geometrical locations of scintillations causing those pulses. A scintillation means, in the form of a scintillating crystal material or a liquid scintillator, is positioned proximate to an array of radioactive samples. Improvement in the accuracy of pulse classification may be obtained by employing collimating means. If a plurality of scintillation crystals are employed to measure the iodine-125 content of samples, a method and means are provided for correcting for variations in crystal light transmission properties, sample volume, and sample container radiation absorption. 2 claims, 7 drawing figures

  2. Does the pretreatment tumor sampling location correspond with metabolic activity on 18F-FDG PET/CT in breast cancer patients scheduled for neoadjuvant chemotherapy?

    Energy Technology Data Exchange (ETDEWEB)

    Koolen, Bas B., E-mail: b.koolen@nki.nl [Department of Nuclear Medicine, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Elshof, Lotte E. [Department of Nuclear Medicine, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Loo, Claudette E. [Department of Radiology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Wesseling, Jelle [Department of Pathology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Vrancken Peeters, Marie-Jeanne T.F.D. [Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Vogel, Wouter V. [Department of Nuclear Medicine, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Rutgers, Emiel J.Th. [Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Valdés Olmos, Renato A. [Department of Nuclear Medicine, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands)

    2013-12-01

    Purpose: To define the correlation between the core biopsy location and the area with highest metabolic activity on 18F-FDG PET/CT in stage II–III breast cancer patients before neoadjuvant chemotherapy. Also, we would like to select a subgroup of patients in which PET/CT information may optimize tumor sampling. Methods: A PET/CT in prone position was acquired in 199 patients with 203 tumors. The distance and relative difference in standardized uptake value (SUV) between core biopsy localization (indicated by a marker) and area with highest degree of FDG uptake were evaluated. A distance ≥2 cm and a relative difference in SUV ≥25% were considered clinically relevant and a combination of both was defined as non-correspondence. Non-correspondence for different tumor characteristics (TNM stage, lesion morphology on MRI and PET/CT, histology, subtype, grade, and Ki-67) was assessed. Results: Non-correspondence was found in 28 (14%) of 203 tumors. Non-correspondence was significantly associated with T-stage, lesion morphology on MRI and PET/CT, tumor diameter, and histologic type. It was more often seen in tumors with a higher T-stage (p = 0.028), diffuse (non-mass) and multifocal tumors on MRI (p = 0.001), diffuse and multifocal tumors on PET/CT (p < 0.001), tumors >3 cm (p < 0.001), and lobular carcinomas (p < 0.001). No association was found with other features. Conclusion: Non-correspondence between the core biopsy location and area with highest FDG uptake is regularly seen in stage II–III breast cancer patients. PET/CT information and possibly FDG-guided biopsies are most likely to improve pretreatment tumor sampling in tumors >3 cm, lobular carcinomas, and diffuse and multifocal tumors.

  3. Gamma ray spectrometry results from core samples collected for RESUME 95

    International Nuclear Information System (INIS)

    Sanderson, D.C.W.; Allyson, J.D.; Toivonen, H.; Honkamaa, T.

    1997-01-01

    Field sampling of an airfield at Vesivehmaa, near Vaeaeksy, Finland (Area I) was carried out between 26-29 May 1995, to establish the radionuclide deposition and inventory of Chernobyl derived 137 Cs, and natural radionuclides. The objective was to establish a common calibration site for in-situ and airborne gamma spectrometers, for Exercise RESUME 95 conducted in August 1995. The report presents the sampling details, handling and treatment. The analyses are discussed with particular emphasis given to 137 Ca, 134 Cs, 40 K, 214 Bi and 208 radionuclides, and the quantification of their respective deposition and inventories. The results have been used to estimate the effective concentrations of nuclides at the calibration site for in-situ and airborne gamma spectrometry, and the depth distribution. For 137 Cs the weighted mean activity per unit area takes on values of 50.7±5.2 kBq m -2 at 1 m ground clearance, 51.1±6.9 kBq m -2 at 50 m height and 47.9±8.5 kBq m -2 at 100 m. The similarity of these values confirms the suitability of the Vesivehmaa site for comparison of in-situ and airborne results despite variations of a factor of two between results from individual cores. The mean α/ρ value for 137 Cs in Area I is 0.77±0.10 cm 2 g -1 (relaxation mass per unit area, β 1.31±0.15 gcm -2 ). Additional soil sampling across parts of Area II (a 6x3 km area selected for mapping Chernobyl deposition) was carried out. The mean level of 137 Cs activity from these samples was 92.4±63 kBq m -2 , a sample taken near Laihansuo showing the largest value obtained at 172 kBq m -2 . (EG)

  4. Location, location, location

    NARCIS (Netherlands)

    Anderson, S.P.; Goeree, J.K.; Ramer, R.

    1997-01-01

    We analyze the canonical location-then-price duopoly game with general log- concave consumer densities. A unique pure-strategy equilibrium to the two-stage game exists if the density is not "too asymmetric" and not "too concave." These criteria are satisfied by many commonly used densities.

  5. LocateP: Genome-scale subcellular-location predictor for bacterial proteins

    Directory of Open Access Journals (Sweden)

    Zhou Miaomiao

    2008-03-01

    Full Text Available Abstract Background In the past decades, various protein subcellular-location (SCL predictors have been developed. Most of these predictors, like TMHMM 2.0, SignalP 3.0, PrediSi and Phobius, aim at the identification of one or a few SCLs, whereas others such as CELLO and Psortb.v.2.0 aim at a broader classification. Although these tools and pipelines can achieve a high precision in the accurate prediction of signal peptides and transmembrane helices, they have a much lower accuracy when other sequence characteristics are concerned. For instance, it proved notoriously difficult to identify the fate of proteins carrying a putative type I signal peptidase (SPIase cleavage site, as many of those proteins are retained in the cell membrane as N-terminally anchored membrane proteins. Moreover, most of the SCL classifiers are based on the classification of the Swiss-Prot database and consequently inherited the inconsistency of that SCL classification. As accurate and detailed SCL prediction on a genome scale is highly desired by experimental researchers, we decided to construct a new SCL prediction pipeline: LocateP. Results LocateP combines many of the existing high-precision SCL identifiers with our own newly developed identifiers for specific SCLs. The LocateP pipeline was designed such that it mimics protein targeting and secretion processes. It distinguishes 7 different SCLs within Gram-positive bacteria: intracellular, multi-transmembrane, N-terminally membrane anchored, C-terminally membrane anchored, lipid-anchored, LPxTG-type cell-wall anchored, and secreted/released proteins. Moreover, it distinguishes pathways for Sec- or Tat-dependent secretion and alternative secretion of bacteriocin-like proteins. The pipeline was tested on data sets extracted from literature, including experimental proteomics studies. The tests showed that LocateP performs as well as, or even slightly better than other SCL predictors for some locations and outperforms

  6. Comparison of radon and radon-daughter grab samples obtained during the winter and summer

    International Nuclear Information System (INIS)

    Karp, K.E.

    1987-08-01

    The Technical Measurements Center (TMC), under the auspices of the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) program, is investigating short-term methods for estimating annual average indoor radon-daughter concentrations (RDC). A field study at 40 sample locations in 26 residential structures in Grand Junction, Colorado, was conducted once in the winter and once in the summer. The short-term methods investigated as part of this study include ten-minute radon and radon-daughter grab sampling and hourly RDC measurements. The results of the field study indicate that ten-minute radon grab samples from basement locations are reproducible over different seasons during controlled sampling conditions. Nonbasement radon and RDC grab samples are highly variable even when the use of the location by the occupant is controlled and the ventilation rate is restricted. The grab sampling was performed under controlled occupied conditions. These results confirm that a short-term radon or RDC measurement in a nonbasement location in a house is not a standardized measurement that can be used to infer an annual average concentration. The hourly RDC measurements were performed under three sets of conditions over a 72-hour period. The three sets of conditions were uncontrolled occupied, controlled occupied, and controlled unoccupied. These results indicate that it is not necessary to relocate the occupants during the time of grab sampling. 8 refs., 8 figs., 10 tabs

  7. Discrete element method (DEM) simulations of stratified sampling during solid dosage form manufacturing.

    Science.gov (United States)

    Hancock, Bruno C; Ketterhagen, William R

    2011-10-14

    Discrete element model (DEM) simulations of the discharge of powders from hoppers under gravity were analyzed to provide estimates of dosage form content uniformity during the manufacture of solid dosage forms (tablets and capsules). For a system that exhibits moderate segregation the effects of sample size, number, and location within the batch were determined. The various sampling approaches were compared to current best-practices for sampling described in the Product Quality Research Institute (PQRI) Blend Uniformity Working Group (BUWG) guidelines. Sampling uniformly across the discharge process gave the most accurate results with respect to identifying segregation trends. Sigmoidal sampling (as recommended in the PQRI BUWG guidelines) tended to overestimate potential segregation issues, whereas truncated sampling (common in industrial practice) tended to underestimate them. The size of the sample had a major effect on the absolute potency RSD. The number of sampling locations (10 vs. 20) had very little effect on the trends in the data, and the number of samples analyzed at each location (1 vs. 3 vs. 7) had only a small effect for the sampling conditions examined. The results of this work provide greater understanding of the effect of different sampling approaches on the measured content uniformity of real dosage forms, and can help to guide the choice of appropriate sampling protocols. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Nature and location of quantum information

    International Nuclear Information System (INIS)

    Griffiths, Robert B.

    2002-01-01

    Quantum information is defined by applying the concepts of ordinary (Shannon) information theory to a quantum sample space consisting of a single framework or consistent family. A classical analogy for a spin-half particle and other arguments show that the infinite amount of information needed to specify a precise vector in its Hilbert space is not a measure of the information carried by a quantum entity with a d-dimensional Hilbert space; the latter is, instead, bounded by log 2 d bits (one bit per qubit). The two bits of information transmitted in dense coding are located not in one but in the correlation between two qubits, consistent with this bound. A quantum channel can be thought of as a structure or collection of frameworks, and the physical location of the information in the individual frameworks can be used to identify the location of the channel. Analysis of a quantum circuit used as a model of teleportation shows that the location of the channel depends upon which structure is employed; for ordinary teleportation it is not (contrary to Deutsch and Hayden) present in the two bits resulting from the Bell-basis measurement, but in correlations of these with a distant qubit. In neither teleportation nor dense coding does information travel backwards in time, nor is it transmitted by nonlocal (superluminal) influences. It is (tentatively) proposed that all aspects of quantum information can in principle be understood in terms of the (basically classical) behavior of information in a particular framework, along with the framework dependence of this information

  9. Tank 241-TX-302C grab samples 302C-TX-97-1A through 302C-TX-97-3B analytical results for the final report

    Energy Technology Data Exchange (ETDEWEB)

    Esch, R.A.

    1998-03-12

    This document is the final report for tank 241-TX-302C grab samples. Six grabs samples (302C-TX-97-1A, 302C-TX-97-1B, 302C-TX-97-2A, 302C-TX-97-2B, 302C-TX-97-3A, and 302C-TX-97-3B) were collected from the catch tank level gauge riser on December 19, 1997. The ``A`` and ``B`` portions from each sample location were composited and analyses were performed on the composites in accordance with the Compatibility Grab Sampling and Analysis Plan (TSAP) (Sasaki, 1997) and the Data Quality Objectives for Tank Farms Waste Compatibility Program (DQO) (Rev. 1: Fowler, 1995; Rev. 2: Mulkey and Miller, 1997). The analytical results are presented in Table 1. No notification limits were exceeded. Appearance and Sample Handling Attachment 1 is provided as a cross-reference for relating the tank farm customer identification numbers with the 222-S Laboratory sample numbers and the portion of sample analyzed. Table 2 provides the appearance information.

  10. Tank 241-TX-302C grab samples, 302C-TX-97-1A through 302C-TX-97-3B analytical results for the final report

    International Nuclear Information System (INIS)

    Esch, R.A.

    1998-01-01

    This document is the final report for tank 241-TX-302C grab samples. Six grabs samples (302C-TX-97-1A, 302C-TX-97-1B, 302C-TX-97-2A, 302C-TX-97-2B, 302C-TX-97-3A, and 302C-TX-97-3B) were collected from the catch tank level gauge riser on December 19, 1997. The ''A'' and ''B'' portions from each sample location were composited and analyses were performed on the composites in accordance with the Compatibility Grab Sampling and Analysis Plan (TSAP) (Sasaki, 1997) and the Data Quality Objectives for Tank Farms Waste Compatibility Program (DQO) (Rev. 1: Fowler, 1995; Rev. 2: Mulkey and Miller, 1997). The analytical results are presented in Table 1. No notification limits were exceeded. Appearance and Sample Handling Attachment 1 is provided as a cross-reference for relating the tank farm customer identification numbers with the 222-S Laboratory sample numbers and the portion of sample analyzed. Table 2 provides the appearance information

  11. Sample preparation for the HAW project and experimental results from the HFR

    International Nuclear Information System (INIS)

    Garcia Celma, A.; Wees, H. van; Miralles, L.

    1990-09-01

    This report deals with the preparation and analysis of samples, during the period May 1989-November 1989, for the High-Active Waste (HAW) project, a large-scale in situ test being performed underground in the Asse salt mine, Remlingen FRG. The development of the technical procedures required, and the scientific results, which regard mostly characterization of Potasas del Llobregat sample, are reported. Prior to using the samples in both the H.A.W. and the H.F.R. experiments they have to be machined to fit their holders. Technical improvements for machining samples of salt are reported. (H.W.). 9 refs.; 68 figs.; 10 tabs

  12. On English Locative Subjects

    Directory of Open Access Journals (Sweden)

    Gabriela Brůhová

    2017-07-01

    Full Text Available The paper analyses English sentences with thematic locative subjects. These subjects were detected as translation counterparts of Czech sentenceinitial locative adverbials realized by prepositional phrases with the prepositions do (into, na (on, v/ve (in, z/ze (from complemented by a noun. In the corresponding English structure, the initial scene-setting adverbial is reflected in the thematic subject, which results in the locative semantics of the subject. The sentences are analysed from syntactic, semantic and FSP aspects. From the syntactic point of view, we found five syntactic patterns of the English sentences with a locative subject (SV, SVA, SVO, SVpassA and SVCs that correspond to Czech sentences with initial locative adverbials. On the FSP level the paper studies the potential of the sentences to implement the Presentation or Quality Scale. Since it is the “semantic content of the verb that actuates the presentation semantics of the sentence” (Duškova, 2015a: 260, major attention is paid to the syntactic-semantic structure of the verb. The analysis of the semantics of the English sentences results in the identification of two semantic classes of verbs which co-occur with the English locative subject.

  13. Gamma ray spectrometry results from core samples collected for RESUME 95

    Energy Technology Data Exchange (ETDEWEB)

    Sanderson, D.C.W.; Allyson, J.D. [SURRC, East Kilbride, Scotland (United Kingdom); Toivonen, H.; Honkamaa, T. [STUK, Helsinki (Finland)

    1997-12-31

    Field sampling of an airfield at Vesivehmaa, near Vaeaeksy, Finland (Area I) was carried out between 26-29 May 1995, to establish the radionuclide deposition and inventory of Chernobyl derived {sup 137}Cs, and natural radionuclides. The objective was to establish a common calibration site for in-situ and airborne gamma spectrometers, for Exercise RESUME 95 conducted in August 1995. The report presents the sampling details, handling and treatment. The analyses are discussed with particular emphasis given to {sup 137}Ca, {sup 134}Cs, {sup 40}K, {sup 214}Bi and {sup 208} radionuclides, and the quantification of their respective deposition and inventories. The results have been used to estimate the effective concentrations of nuclides at the calibration site for in-situ and airborne gamma spectrometry, and the depth distribution. For {sup 137}Cs the weighted mean activity per unit area takes on values of 50.7{+-}5.2 kBq m{sup -2} at 1 m ground clearance, 51.1{+-}6.9 kBq m{sup -2} at 50 m height and 47.9{+-}8.5 kBq m{sup -2} at 100 m. The similarity of these values confirms the suitability of the Vesivehmaa site for comparison of in-situ and airborne results despite variations of a factor of two between results from individual cores. The mean {alpha}/{rho} value for {sup 137}Cs in Area I is 0.77{+-}0.10 cm{sup 2}g{sup -1} (relaxation mass per unit area, {beta} 1.31{+-}0.15 gcm{sup -2}). Additional soil sampling across parts of Area II (a 6x3 km area selected for mapping Chernobyl deposition) was carried out. The mean level of {sup 137}Cs activity from these samples was 92.4{+-}63 kBq m{sup -2}, a sample taken near Laihansuo showing the largest value obtained at 172 kBq m{sup -2}. (EG). 17 refs.

  14. Gamma ray spectrometry results from core samples collected for RESUME 95

    Energy Technology Data Exchange (ETDEWEB)

    Sanderson, D C.W.; Allyson, J D [SURRC, East Kilbride, Scotland (United Kingdom); Toivonen, H; Honkamaa, T [STUK, Helsinki (Finland)

    1998-12-31

    Field sampling of an airfield at Vesivehmaa, near Vaeaeksy, Finland (Area I) was carried out between 26-29 May 1995, to establish the radionuclide deposition and inventory of Chernobyl derived {sup 137}Cs, and natural radionuclides. The objective was to establish a common calibration site for in-situ and airborne gamma spectrometers, for Exercise RESUME 95 conducted in August 1995. The report presents the sampling details, handling and treatment. The analyses are discussed with particular emphasis given to {sup 137}Ca, {sup 134}Cs, {sup 40}K, {sup 214}Bi and {sup 208} radionuclides, and the quantification of their respective deposition and inventories. The results have been used to estimate the effective concentrations of nuclides at the calibration site for in-situ and airborne gamma spectrometry, and the depth distribution. For {sup 137}Cs the weighted mean activity per unit area takes on values of 50.7{+-}5.2 kBq m{sup -2} at 1 m ground clearance, 51.1{+-}6.9 kBq m{sup -2} at 50 m height and 47.9{+-}8.5 kBq m{sup -2} at 100 m. The similarity of these values confirms the suitability of the Vesivehmaa site for comparison of in-situ and airborne results despite variations of a factor of two between results from individual cores. The mean {alpha}/{rho} value for {sup 137}Cs in Area I is 0.77{+-}0.10 cm{sup 2}g{sup -1} (relaxation mass per unit area, {beta} 1.31{+-}0.15 gcm{sup -2}). Additional soil sampling across parts of Area II (a 6x3 km area selected for mapping Chernobyl deposition) was carried out. The mean level of {sup 137}Cs activity from these samples was 92.4{+-}63 kBq m{sup -2}, a sample taken near Laihansuo showing the largest value obtained at 172 kBq m{sup -2}. (EG). 17 refs.

  15. SOLVENT HOLD TANK SAMPLE RESULTS FOR MCU-13-189, MCU-13-190, AND MCU-13-191: QUARTERLY SAMPLE FROM SEPTEMBER 2013

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F.; Taylor-Pashow, K.

    2013-10-31

    Savannah River National Laboratory (SRNL) analyzed solvent samples from Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-13-189, MCU-13-190, and MCU-13-191 received on September 4, 2013 are reported. The results show that the solvent (remaining heel in the SHT tank) at MCU contains excess Isopar L and a deficit concentration of modifier and trioctylamine when compared to the standard MCU solvent. As with the previous solvent sample results, these analyses indicate that the solvent does not require Isopar L trimming at this time. Since MCU is switching to NGS, there is no need to add TOA nor modifier. SRNL also analyzed the SHT sample for {{sup 137}Cs content and determined the measured value is within tolerance and the value has returned to levels observed in 2011.

  16. Improvement of vision measurement accuracy using Zernike moment based edge location error compensation model

    International Nuclear Information System (INIS)

    Cui, J W; Tan, J B; Zhou, Y; Zhang, H

    2007-01-01

    This paper presents the Zernike moment based model developed to compensate edge location errors for further improvement of the vision measurement accuracy by compensating the slight changes resulting from sampling and establishing mathematic expressions for subpixel location of theoretical and actual edges which are either vertical to or at an angle with X-axis. Experimental results show that the proposed model can be used to achieve a vision measurement accuracy of up to 0.08 pixel while the measurement uncertainty is less than 0.36μm. It is therefore concluded that as a model which can be used to achieve a significant improvement of vision measurement accuracy, the proposed model is especially suitable for edge location of images with low contrast

  17. Results For The Third Quarter 2010 Tank 50 WAC Slurry Sample: Chemical And Radionuclide Contaminant Results

    International Nuclear Information System (INIS)

    Reigel, M.; Bibler, N.

    2010-01-01

    This report details the chemical and radionuclide contaminant results for the characterization of the 2010 Third Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (i) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section. (ii) The reported detection limits for 94 Nb, 247 Cm and 249 Cf are above the requested limits from Reference 4. However, they are below the limits established in Reference 3. (iii) The reported detection limit for 242m Am is greater than the requested limit from Attachment 8.4 of the WAC. (iv) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC. (v) The reported concentration of Isopropanol is greater than the limit from Table 4 of the WAC. (vi) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the GC/MS; however, the results may not accurately represent the concentrations of the analytes in Tank 50.

  18. Protein (multi-)location prediction: using location inter-dependencies in a probabilistic framework.

    Science.gov (United States)

    Simha, Ramanuja; Shatkay, Hagit

    2014-03-19

    Knowing the location of a protein within the cell is important for understanding its function, role in biological processes, and potential use as a drug target. Much progress has been made in developing computational methods that predict single locations for proteins. Most such methods are based on the over-simplifying assumption that proteins localize to a single location. However, it has been shown that proteins localize to multiple locations. While a few recent systems attempt to predict multiple locations of proteins, their performance leaves much room for improvement. Moreover, they typically treat locations as independent and do not attempt to utilize possible inter-dependencies among locations. Our hypothesis is that directly incorporating inter-dependencies among locations into both the classifier-learning and the prediction process can improve location prediction performance. We present a new method and a preliminary system we have developed that directly incorporates inter-dependencies among locations into the location-prediction process of multiply-localized proteins. Our method is based on a collection of Bayesian network classifiers, where each classifier is used to predict a single location. Learning the structure of each Bayesian network classifier takes into account inter-dependencies among locations, and the prediction process uses estimates involving multiple locations. We evaluate our system on a dataset of single- and multi-localized proteins (the most comprehensive protein multi-localization dataset currently available, derived from the DBMLoc dataset). Our results, obtained by incorporating inter-dependencies, are significantly higher than those obtained by classifiers that do not use inter-dependencies. The performance of our system on multi-localized proteins is comparable to a top performing system (YLoc+), without being restricted only to location-combinations present in the training set.

  19. Plasma assisted growth of MoO{sub 3} films on different substrate locations relative to sublimation source

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Rabindar K., E-mail: rkrksharma6@gmail.com; Saini, Sujit K.; Kumar, Prabhat; Singh, Megha; Reddy, G. B. [Thin film laboratory, Department of Physics, Indian Institute of Technology Delhi, New Delhi – 110016 (India)

    2016-05-06

    In the present paper, we reported the role of substrate locations relative to source on the growth of MoO{sub 3} films deposited on Ni coated glass substrates using plasma assisted sublimation process (PASP). According to the XRD and SEM results, substrate location is very crucial factor to control the morphology of MoO{sub 3} films and the best nanostructure growth (in terms of alignments and features) is obtained in case of Sample B (in which substrate is placed on source). The structural results point out that all films exhibit only orthorhombic phase of molybdenum oxide (i.e. α-MoO{sub 3})but the most preferential growth is recorded in Sample B due to the presence of intense peaks crossponding to only (0 k 0) family of crystal planes (k = 2, 4,6..). The Raman analysis again confirms the orthorhombic nature of MoO{sub 3} NFs and details of vibrational bondsin Sample B have been given in the present report. The MoO{sub 3} NFs show intense PL emission in wavelength range of 300-700 nm with three peaks located at 415, 490, and 523 nm in accordance to the improved crystallinity in Sample B.

  20. Rheology and TIC/TOC results of ORNL tank samples

    International Nuclear Information System (INIS)

    Pareizs, J. M.; Hansen, E. K.

    2013-01-01

    The Savannah River National Laboratory (SRNL)) was requested by Oak Ridge National Laboratory (ORNL) to perform total inorganic carbon (TIC), total organic carbon (TOC), and rheological measurements for several Oak Ridge tank samples. As received slurry samples were diluted and submitted to SRNL-Analytical for TIC and TOC analyses. Settled solids yield stress (also known as settled shear strength) of the as received settled sludge samples were determined using the vane method and these measurements were obtained 24 hours after the samples were allowed to settled undisturbed. Rheological or flow properties (Bingham Plastic viscosity and Bingham Plastic yield stress) were determined from flow curves of the homogenized or well mixed samples. Other targeted total suspended solids (TSS) concentrations samples were also analyzed for flow properties and these samples were obtained by diluting the as-received sample with de-ionized (DI) water

  1. Results of elemental analyses of water and waterborne sediment samples from areas of Alaska proposed for the Chukchi Imuruk National Reserve, Selawik National Wildlife Refuge, and Cape Krusenstern National Monument

    International Nuclear Information System (INIS)

    Sharp, R.R. Jr.

    1978-10-01

    During July--August 1976, waters and sediments were collected from streams and lakes over an area of 100,000 km 2 around Kotzebue, Alaska, as part of the National Uranium Resource Evaluation Hydrogeochemical and Stream Sediment Reconnaissance. The work provides multielement results for 949 waters and 886 sediments from 979 locations. Of these, 492 waters and 452 sediments are from 517 locations in the proposed Chukchi Imuruk Reserve; 447 waters and 423 sediments are from 451 locations in the proposed Selawik Wildlife Refuge; and 10 waters and 11 sediments are from 11 locations in the proposed Cape Krusenstern Monument. The field data, with concentrations of 13 elements in the waters and 43 in the sediments, are presented, and the sample locations are shown on accompanying plates. The waters were analyzed for uranium by fluorometry or delayed-neutron counting and calcium, chromium, cobalt, copper, iron, lead, magnesium, manganese, molybdenum, nickel, titanium, and zinc by plasma-source emission spectrography. The sediment samples were analyzed for uranium by delayed-neutron counting, beryllium and lithium by arc-source emission spectrography, bismuth, cadmium, copper, lead, nickel, niobium, silver, tin, and tungsten by x-ray fluorescence, and aluminum, antimony, barium, calcium, cerium, cesium, chlorine, chromium, cobalt, dysprosium, europium, gold, hafnium, iron, lanthanum, lutetium, magnesium, manganese, potassium, rubidium, samarium, scandium, sodium, strontium, tantalum, terbium, thorium, titanium, vanadium, ytterbium, and zinc by neutron activation. Uranium to thorium ratios in each sediment are also provided

  2. Sample Results from the Interim Salt Disposition Program Macrobatch 8 Tank 21H Qualification Samples

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Washington, A. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-01-01

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 8 for the Interim Salt Disposition Program (ISDP). An Actinide Removal Process (ARP) and several Extraction-Scrub- Strip (ESS) tests were also performed. This document reports characterization data on the samples of Tank 21H as well as simulated performance of ARP and the Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU). No issues with the projected Salt Batch 8 strategy are identified. A demonstration of the monosodium titanate (MST) (0.2 g/L) removal of strontium and actinides provided acceptable average decontamination factors for plutonium of 2.62 (4 hour) and 2.90 (8 hour); and average strontium decontamination factors of 21.7 (4 hour) and 21.3 (8 hour). These values are consistent with results from previous salt batch ARP tests. The two ESS tests also showed acceptable performance with extraction distribution ratios (D(Cs)) values of 52.5 and 50.4 for the Next Generation Solvent (NGS) blend (from MCU) and NGS (lab prepared), respectively. These values are consistent with results from previous salt batch ESS tests. Even though the performance is acceptable, SRNL recommends that a model for predicting extraction behavior for cesium removal for the blended solvent and NGS be developed in order to improve our predictive capabilities for the ESS tests.

  3. Sample results from the Interim Salt Disposition Program Macrobatch 8 Tank 21H qualification samples

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Washington, II, A. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-01-13

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 8 for the Interim Salt Disposition Program (ISDP). An Actinide Removal Process (ARP) and several Extraction-Scrub-Strip (ESS) tests were also performed. This document reports characterization data on the samples of Tank 21H as well as simulated performance of ARP and the Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU). No issues with the projected Salt Batch 8 strategy are identified. A demonstration of the monosodium titanate (MST) (0.2 g/L) removal of strontium and actinides provided acceptable average decontamination factors for plutonium of 2.62 (4 hour) and 2.90 (8 hour); and average strontium decontamination factors of 21.7 (4 hour) and 21.3 (8 hour). These values are consistent with results from previous salt batch ARP tests. The two ESS tests also showed acceptable performance with extraction distribution ratios (D(Cs)) values of 52.5 and 50.4 for the Next Generation Solvent (NGS) blend (from MCU) and NGS (lab prepared), respectively. These values are consistent with results from previous salt batch ESS tests. Even though the performance is acceptable, SRNL recommends that a model for predicting extraction behavior for cesium removal for the blended solvent and NGS be developed in order to improve our predictive capabilities for the ESS tests.

  4. Low complexity algorithms to independently and jointly estimate the location and range of targets using FMCW

    KAUST Repository

    Ahmed, Sajid

    2017-05-12

    The estimation of angular-location and range of a target is a joint optimization problem. In this work, to estimate these parameters, by meticulously evaluating the phase of the received samples, low complexity sequential and joint estimation algorithms are proposed. We use a single-input and multiple-output (SIMO) system and transmit frequency-modulated continuous-wave signal. In the proposed algorithm, it is shown that by ignoring very small value terms in the phase of the received samples, fast-Fourier-transform (FFT) and two-dimensional FFT can be exploited to estimate these parameters. Sequential estimation algorithm uses FFT and requires only one received snapshot to estimate the angular-location. Joint estimation algorithm uses two-dimensional FFT to estimate the angular-location and range of the target. Simulation results show that joint estimation algorithm yields better mean-squared-error (MSE) for the estimation of angular-location and much lower run-time compared to conventional MUltiple SIgnal Classification (MUSIC) algorithm.

  5. Low complexity algorithms to independently and jointly estimate the location and range of targets using FMCW

    KAUST Repository

    Ahmed, Sajid; Jardak, Seifallah; Alouini, Mohamed-Slim

    2017-01-01

    The estimation of angular-location and range of a target is a joint optimization problem. In this work, to estimate these parameters, by meticulously evaluating the phase of the received samples, low complexity sequential and joint estimation algorithms are proposed. We use a single-input and multiple-output (SIMO) system and transmit frequency-modulated continuous-wave signal. In the proposed algorithm, it is shown that by ignoring very small value terms in the phase of the received samples, fast-Fourier-transform (FFT) and two-dimensional FFT can be exploited to estimate these parameters. Sequential estimation algorithm uses FFT and requires only one received snapshot to estimate the angular-location. Joint estimation algorithm uses two-dimensional FFT to estimate the angular-location and range of the target. Simulation results show that joint estimation algorithm yields better mean-squared-error (MSE) for the estimation of angular-location and much lower run-time compared to conventional MUltiple SIgnal Classification (MUSIC) algorithm.

  6. [Confirming Indicators of Qualitative Results by Chromatography-mass Spectrometry in Biological Samples].

    Science.gov (United States)

    Liu, S D; Zhang, D M; Zhang, W; Zhang, W F

    2017-04-01

    Because of the exist of complex matrix, the confirming indicators of qualitative results for toxic substances in biological samples by chromatography-mass spectrometry are different from that in non-biological samples. Even in biological samples, the confirming indicators are different in various application areas. This paper reviews the similarities and differences of confirming indicators for the analyte in biological samples by chromatography-mass spectrometry in the field of forensic toxicological analysis and other application areas. These confirming indicators include retention time (RT), relative retention time (RRT), signal to noise (S/N), characteristic ions, relative abundance of characteristic ions, parent ion-daughter ion pair and abundance ratio of ion pair, etc. Copyright© by the Editorial Department of Journal of Forensic Medicine.

  7. Locating industrial VOC sources with aircraft observations

    International Nuclear Information System (INIS)

    Toscano, P.; Gioli, B.; Dugheri, S.; Salvini, A.; Matese, A.; Bonacchi, A.; Zaldei, A.; Cupelli, V.; Miglietta, F.

    2011-01-01

    Observation and characterization of environmental pollution, focussing on Volatile Organic Compounds (VOCs), in a high-risk industrial area, are particularly important in order to provide indications on a safe level of exposure, indicate eventual priorities and advise on policy interventions. The aim of this study is to use the Solid Phase Micro Extraction (SPME) method to measure VOCs, directly coupled with atmospheric measurements taken on a small aircraft environmental platform, to evaluate and locate the presence of VOC emission sources in the Marghera industrial area. Lab analysis of collected SPME fibres and subsequent analysis of mass spectrum and chromatograms in Scan Mode allowed the detection of a wide range of VOCs. The combination of this information during the monitoring campaign allowed a model (Gaussian Plume) to be implemented that estimates the localization of emission sources on the ground. - Highlights: → Flight plan aimed at sampling industrial area at various altitudes and locations. → SPME sampling strategy was based on plume detection by means of CO 2 . → Concentrations obtained were lower than the limit values or below the detection limit. → Scan mode highlighted presence of γ-butyrolactone (GBL) compound. → Gaussian dispersion modelling was used to estimate GBL source location and strength. - An integrated strategy based on atmospheric aircraft observations and dispersion modelling was developed, aimed at estimating spatial location and strength of VOC point source emissions in industrial areas.

  8. A Partial Join Approach for Mining Co-Location Patterns: A Summary of Results

    National Research Council Canada - National Science Library

    Yoo, Jin S; Shekhar, Shashi

    2005-01-01

    .... They propose a novel partial-join approach for mining co-location patterns efficiently. It transactionizes continuous spatial data while keeping track of the spatial information not modeled by transactions...

  9. Using Pictures to Assess Pain Location in Children.

    Science.gov (United States)

    Mesko, Phyllis J; Eliades, Aris Beoglos

    2018-06-01

    This study uses the Pain Area Locator (PAL) tool, a picture communication aid with body and medical equipment icons, to identify pain location in postoperative pediatric patients and assesses discrepancies between nurses' pain location assessment and pain location identified using the PAL tool. This descriptive study used a quantitative, comparative design, with a convenience sample of pediatric postoperative patients undergoing same-day surgeries at a free-standing, acute care, Magnet designated pediatric hospital. The child's pain location was assessed by asking the child to point to one of the 12 pictures on the PAL tool of where they hurt. All 41 (100%) of the postoperative children in the study demonstrated ability to use the PAL tool. The child identified a pain location in 34 assessments (83%) when the nurse documented no pain location. This investigation expands on previous evidence supporting that children can use the PAL tool to identify the pain location postoperatively. Copyright © 2016 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.

  10. Report of testing and sampling of municipal supply well PM-4

    International Nuclear Information System (INIS)

    Koch, Richard J.; Longmire, Patrick; Rogers, David B.; Mullen, Ken

    1999-01-01

    During drilling of regional aquifer characterization borehole R-25, located in the western part of Los Alamos National Laboratory (LANL) at Technical Area (TA) 16, groundwater samples were collected from perched zones of saturation and the regional aquifer that contained elevated levels of high explosive (HE) compounds. One of the nearest Los Alamos County municipal supply wells potentially located down gradient from borehole R-25 is PM-4, located on Mesita del Buey at the west end of TA-54. During the winter of 1998 and 1999 the pump in PM-4 had been removed from the well for scheduled maintenance by the Los Alamos County Public Utilities Department (PUD). Because the pump was removed from PM-4, the opportunity existed to enter the well to (1) perform tests to determine where within the regional aquifer groundwater entered the well and (2) collect groundwater samples from the producing zones for analyses to determine if HE contaminants were present in discrete zones within the regional aquifer. The report of the activities that were performed during March 1999 for the testing and sampling of municipal supply well PM-4 is provided. The report provides a description of the field activities associated with the two phases of the project, including (1) the results of the static and dynamic spinner log surveys, and (2) a description of the sampling activities and the field-measured groundwater quality parameters that were obtained during sampling activities. This report also provides the analytical results of the groundwater samples and a brief discussion of the results of the project

  11. Reliability testing of failed fuel location system

    International Nuclear Information System (INIS)

    Vieru, G.

    1996-01-01

    This paper presents the experimental reliability tests performed in order to prove the reliability parameters for Failed Fuel Location System (FFLS), equipment used to detect in which channel of a particular heat transport loop a fuel failure is located, and to find in which channel what particular bundle pair is failed. To do so, D20 samples from each reactor channel are sequentially monitored to detect a comparatively high level of delayed neutron activity. 15 refs, 8 figs, 2 tabs

  12. Superfund Site Information - Site Sampling Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — This asset includes Superfund site-specific sampling information including location of samples, types of samples, and analytical chemistry characteristics of...

  13. Dealing with Insufficient Location Fingerprints in Wi-Fi Based Indoor Location Fingerprinting

    Directory of Open Access Journals (Sweden)

    Kai Dong

    2017-01-01

    Full Text Available The development of the Internet of Things has accelerated research in the indoor location fingerprinting technique, which provides value-added localization services for existing WLAN infrastructures without the need for any specialized hardware. The deployment of a fingerprinting based localization system requires an extremely large amount of measurements on received signal strength information to generate a location fingerprint database. Nonetheless, this requirement can rarely be satisfied in most indoor environments. In this paper, we target one but common situation when the collected measurements on received signal strength information are insufficient, and show limitations of existing location fingerprinting methods in dealing with inadequate location fingerprints. We also introduce a novel method to reduce noise in measuring the received signal strength based on the maximum likelihood estimation, and compute locations from inadequate location fingerprints by using the stochastic gradient descent algorithm. Our experiment results show that our proposed method can achieve better localization performance even when only a small quantity of RSS measurements is available. Especially when the number of observations at each location is small, our proposed method has evident superiority in localization accuracy.

  14. Joint Polish–Finnish sampling of surface waters around the phosphogypsum waste stacks in Gdańsk and Police from 1 to 3 July 2013 – Results of the expedition

    OpenAIRE

    Räike, Antti; Koskela, Jarkko; Knuuttila, Seppo; Lehtoranta, Jouni; Pitkänen, Heikki; Risto, Maarit; Vuorinen, Jyrki

    2015-01-01

    The report describes the results of the joint Polish–Finnish sampling expedition aimed at estimating the possible effects of the two Polish phosphogypsum stacks located in Wislinka (Gdańsk) and Police on the loading of the Baltic Sea and the nearby watercourses. The joint expedition was based on the agreement between the Polish and Finnish Ministers of the Environment in June 2013. The results indicate a clear effect of the phosphogypsum stack on phosphate and total phosphorus concentratio...

  15. Evidence for ultra-fast outflows in radio-quiet AGNs: III - location and energetics

    OpenAIRE

    Tombesi, F.; Cappi, M.; Reeves, J. N.; Braito, V.

    2012-01-01

    Using the results of a previous X-ray photo-ionization modelling of blue-shifted Fe K absorption lines on a sample of 42 local radio-quiet AGNs observed with XMM-Newton, in this letter we estimate the location and energetics of the associated ultra-fast outflows (UFOs). Due to significant uncertainties, we are essentially able to place only lower/upper limits. On average, their location is in the interval ~0.0003-0.03pc (~10^2-10^4 r_s) from the central black hole, consistent with what is exp...

  16. Environmental monitoring at the nuclear power plants and Studsvik 1992-1993. Results from measurements of radionuclide contents of environmental samples, and from random checks by SSI

    International Nuclear Information System (INIS)

    Bengtson, P.; Larsson, C.M.; Simenstad, P.; Suomela, J.

    1995-09-01

    Marine samples from the vicinity of the plants show elevated radionuclide concentrations, caused by discharges from the plants. Very low concentrations are noted in terrestrial samples. At several locations, the effects of the Chernobyl disaster still dominates. Control samples measured by SSI have confirmed the measurements performed by the operators. 8 refs, 6 tabs, 46 figs

  17. Effect of order of draw of blood samples during phlebotomy on routine biochemistry results.

    Science.gov (United States)

    Sulaiman, Raashda A; Cornes, Michael P; Whitehead, Simon J; Othonos, Nadia; Ford, Clare; Gama, Rousseau

    2011-11-01

    To investigate whether incorrect order of draw of blood samples during phlebotomy causes in vitro potassium ethylenediaminetetraacetic acid EDTA (kEDTA) contamination of blood samples. Serum kEDTA, potassium, calcium, magnesium, alkaline phosphatase, zinc and iron concentrations were measured in blood samples drawn before and after collecting blood into kEDTA containing sample tubes by an experienced phlebotomist using the Sarstedt Safety Monovette system. EDTA was undetectable in all samples. The concentrations of other analytes were similar in blood samples drawn before and after collection of the EDTA blood sample. Order of draw of blood samples using the Sarstedt Safety Monovette system has no effect on serum biochemistry results, when samples are taken by an experienced phlebotomist.

  18. Analytical results from salt batch 9 routine DSSHT and SEHT monthly samples

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-06-01

    Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 9 have been analyzed for 238Pu, 90Sr, 137Cs, cations (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and anions (Ion Chromatography Anions - IC-A). The analytical results from the current microbatch samples are similar to those from previous macrobatch samples. The Cs removal continues to be acceptable, with decontamination factors (DF) averaging 25700 (107% RSD). The bulk chemistry of the DSSHT and SEHT samples do not show any signs of unusual behavior, other than lacking the anticipated degree of dilution that is calculated to occur during Modular Caustic-Side Solvent Extraction Unit (MCU) processing.

  19. LOCATION-BASED SERVICES USING SIP

    OpenAIRE

    Abdullah Azfar,; Md. Sakhawat Hossen,; María José Peroza Marval; Razib Hayat Khan

    2010-01-01

    Due to the popularity of Location-Based Services and IP telephony, we decided to review a number of different proposals to implement Location-Based Services over a SIP-based mobile network. The result is an interesting overview about the potential functionalities of Location-Based Services and the capabilities of SIP for implementingthese services.

  20. Source Location of Noble Gas Plumes

    International Nuclear Information System (INIS)

    Hoffman, I.; Ungar, K.; Bourgouin, P.; Yee, E.; Wotawa, G.

    2015-01-01

    In radionuclide monitoring, one of the most significant challenges from a verification or surveillance perspective is the source location problem. Modern monitoring/surveillance systems employ meteorological source reconstruction — for example, the Fukushima accident, CRL emissions analysis and even radon risk mapping. These studies usually take weeks to months to conduct, involving multidisciplinary teams representing meteorology; dispersion modelling; radionuclide sampling and metrology; and, when relevant, proper representation of source characteristics (e.g., reactor engineering expertise). Several different approaches have been tried in an attempt to determine useful techniques to apply to the source location problem and to develop rigorous methods that combine all potentially relevant observations and models to identify a most probable source location and size with uncertainties. The ultimate goal is to understand the utility and limitations of these techniques so they can transition from R&D to operational tools. (author)

  1. Automatic cross-sectioning and monitoring system locates defects in electronic devices

    Science.gov (United States)

    Jacobs, G.; Slaughter, B.

    1971-01-01

    System consists of motorized grinding and lapping apparatus, sample holder, and electronic control circuit. Low power microscope examines device to pinpoint location of circuit defect, and monitor displays output signal when defect is located exactly.

  2. Network and adaptive sampling

    CERN Document Server

    Chaudhuri, Arijit

    2014-01-01

    Combining the two statistical techniques of network sampling and adaptive sampling, this book illustrates the advantages of using them in tandem to effectively capture sparsely located elements in unknown pockets. It shows how network sampling is a reliable guide in capturing inaccessible entities through linked auxiliaries. The text also explores how adaptive sampling is strengthened in information content through subsidiary sampling with devices to mitigate unmanageable expanding sample sizes. Empirical data illustrates the applicability of both methods.

  3. Design of a TDOA location engine and development of a location system based on chirp spread spectrum.

    Science.gov (United States)

    Wang, Rui-Rong; Yu, Xiao-Qing; Zheng, Shu-Wang; Ye, Yang

    2016-01-01

    Location based services (LBS) provided by wireless sensor networks have garnered a great deal of attention from researchers and developers in recent years. Chirp spread spectrum (CSS) signaling formatting with time difference of arrival (TDOA) ranging technology is an effective LBS technique in regards to positioning accuracy, cost, and power consumption. The design and implementation of the location engine and location management based on TDOA location algorithms were the focus of this study; as the core of the system, the location engine was designed as a series of location algorithms and smoothing algorithms. To enhance the location accuracy, a Kalman filter algorithm and moving weighted average technique were respectively applied to smooth the TDOA range measurements and location results, which are calculated by the cooperation of a Kalman TDOA algorithm and a Taylor TDOA algorithm. The location management server, the information center of the system, was designed with Data Server and Mclient. To evaluate the performance of the location algorithms and the stability of the system software, we used a Nanotron nanoLOC Development Kit 3.0 to conduct indoor and outdoor location experiments. The results indicated that the location system runs stably with high accuracy at absolute error below 0.6 m.

  4. Characterization of Tank 16H Annulus Samples Part II: Leaching Results

    International Nuclear Information System (INIS)

    Hay, M.; Reboul, S.

    2012-01-01

    The closure of Tank 16H will require removal of material from the annulus of the tank. Samples from Tank 16H annulus were characterized and tested to provide information to evaluate various alternatives for removing the annulus waste. The analysis found all four annulus samples to be composed mainly of Si, Na, and Al and lesser amounts of other elements. The XRD data indicate quartz (SiO 2 ) and sodium aluminum nitrate silicate hydrate (Na 8 (Al 6 Si 6 O 24 )(NO 3 ) 2 .4H 2 O) as the predominant crystalline mineral phases in the samples. The XRD data also indicate the presence of crystalline sodium nitrate (NaNO 3 ), sodium nitrite (NaNO 2 ), gibbsite (Al(OH) 3 ), hydrated sodium bicarbonate (Na 3 H(CO 3 ) 2 .2H 2 O), and muscovite (KAl 2 (AlSi 3 O 10 )(OH) 2 ). Based on the weight of solids remaining at the end of the test, the water leaching test results indicate 20-35% of the solids dissolved after three contacts with an approximately 3:1 volume of water at 45 C. The chemical analysis of the leachates and the XRD results of the remaining solids indicate sodium salts of nitrate, nitrite, sulfate, and possibly carbonate/bicarbonate make up the majority of the dissolved material. The majority of these salts were dissolved in the first water contact and simply diluted with each subsequent water contact. The water leaching removed large amounts of the uranium in two of the samples and approximately 1/3 of the 99 Tc from all four samples. Most of the other radionuclides analyzed showed low solubility in the water leaching test. The oxalic acid leaching test result indicate approximately 34-47% of the solids in the four annulus samples will dissolve after three contacts with an approximately 3:1 volume of acid to solids at 45 C. The same sodium salts found in the water leaching test comprise the majority of dissolved material in the oxalic acid leaching test. However, the oxalic acid was somewhat more effective in dissolving radionuclides than the water leach. In

  5. UMTRA water sampling and analysis plan, Green River, Utah

    International Nuclear Information System (INIS)

    Papusch, R.

    1993-12-01

    The purpose of this water sampling and analysis plan (WSAP) is to provide a basis for groundwater and surface water sampling at the Green River Uranium Mill Tailing Remedial Action (UMTRA) Project site. This WSAP identifies and justifies the sampling locations, analytical parameters, detection limits, and sampling frequency for the monitoring locations

  6. Quantitative analysis of Curcuminoid collected from different location in Indonesia by TLC-Densitometry and its antioxidant capacity

    Science.gov (United States)

    Wahyuni, D. S. C.; Artanti, A. N.; Rinanto, Y.

    2018-04-01

    Curcuminoid, consisting of curcumin, demethoxycurcumin and bis demethoxycurcumin, is the active compound in Curcuma longa L. rhizome. It yielded vary depend on the environment and varieties. Curcumin has been known to have a potent antioxidants activity. The present work was conducted to assess the curcuminoid content and antioxidant capacity in the crude extracts of C. longa L. collected from eight different locations in Indonesia. Samples were collected from eight locations including Java island, Sumatera island and Nusa Tenggara island. All samples were extracted using 96% ethanol and analyzed quantitatively using TLC-Densitometry. Antioxidant activity was assessed using diphenylpicrylhydrazyl (DPPH) radical scavenging assay and analyzed at 517 nm using a spectrophotometer. Curcuminoid content in C. longa varied among eight different locations (0.53±0.05 - 5.33±0.12 % w/w). The highest curcumin, demethoxycurcumin and bisdemethoxycurcumin yield were found in the samples from Magetan (5.33±0.12%, 1.54±0.05%, 0.46±0.02% w/w, respectively). In contrast, the lowest curcumin, demethoxycurcumin and bisdemethoxycurcumin yield were found in the sample from Demak (0.53±0.05%, 0.17±0.05%, 0.17±0.05% w/w, respectively). Antioxidant capacity showed similar for all places unless sample from Magetan which exhibited two times lower than other locations. It is apparently curcuminoid content and antioxidant activity varied among places. These results are useful information for curcuminoid standardization method in pharmaceutical products.

  7. An Indoor Location-Based Control System Using Bluetooth Beacons for IoT Systems.

    Science.gov (United States)

    Huh, Jun-Ho; Seo, Kyungryong

    2017-12-19

    The indoor location-based control system estimates the indoor position of a user to provide the service he/she requires. The major elements involved in the system are the localization server, service-provision client, user application positioning technology. The localization server controls access of terminal devices (e.g., Smart Phones and other wireless devices) to determine their locations within a specified space first and then the service-provision client initiates required services such as indoor navigation and monitoring/surveillance. The user application provides necessary data to let the server to localize the devices or allow the user to receive various services from the client. The major technological elements involved in this system are indoor space partition method, Bluetooth 4.0, RSSI (Received Signal Strength Indication) and trilateration. The system also employs the BLE communication technology when determining the position of the user in an indoor space. The position information obtained is then used to control a specific device(s). These technologies are fundamental in achieving a "Smart Living". An indoor location-based control system that provides services by estimating user's indoor locations has been implemented in this study (First scenario). The algorithm introduced in this study (Second scenario) is effective in extracting valid samples from the RSSI dataset but has it has some drawbacks as well. Although we used a range-average algorithm that measures the shortest distance, there are some limitations because the measurement results depend on the sample size and the sample efficiency depends on sampling speeds and environmental changes. However, the Bluetooth system can be implemented at a relatively low cost so that once the problem of precision is solved, it can be applied to various fields.

  8. An Indoor Location-Based Control System Using Bluetooth Beacons for IoT Systems

    Directory of Open Access Journals (Sweden)

    Jun-Ho Huh

    2017-12-01

    Full Text Available The indoor location-based control system estimates the indoor position of a user to provide the service he/she requires. The major elements involved in the system are the localization server, service-provision client, user application positioning technology. The localization server controls access of terminal devices (e.g., Smart Phones and other wireless devices to determine their locations within a specified space first and then the service-provision client initiates required services such as indoor navigation and monitoring/surveillance. The user application provides necessary data to let the server to localize the devices or allow the user to receive various services from the client. The major technological elements involved in this system are indoor space partition method, Bluetooth 4.0, RSSI (Received Signal Strength Indication and trilateration. The system also employs the BLE communication technology when determining the position of the user in an indoor space. The position information obtained is then used to control a specific device(s. These technologies are fundamental in achieving a “Smart Living”. An indoor location-based control system that provides services by estimating user’s indoor locations has been implemented in this study (First scenario. The algorithm introduced in this study (Second scenario is effective in extracting valid samples from the RSSI dataset but has it has some drawbacks as well. Although we used a range-average algorithm that measures the shortest distance, there are some limitations because the measurement results depend on the sample size and the sample efficiency depends on sampling speeds and environmental changes. However, the Bluetooth system can be implemented at a relatively low cost so that once the problem of precision is solved, it can be applied to various fields.

  9. Latin Hypercube Sampling (LHS) at variable resolutions for enhanced watershed scale Soil Sampling and Digital Soil Mapping.

    Science.gov (United States)

    Hamalainen, Sampsa; Geng, Xiaoyuan; He, Juanxia

    2017-04-01

    attributes. When working within the same spatial resolution for covariates, however only modifying the desired number of sampling points produced, the change of point location portrayed a strong geospatial relationship when using continuous data. Access to agricultural fields and adjacent land uses is often "pinned" as the greatest deterrent to performing soil sampling for both soil survey and soil attribute validation work. The lack of access can be a result of poor road access and/or difficult geographical conditions to navigate for field work individuals. This seems a simple yet continuous issue to overcome for the scientific community and in particular, soils professionals. The ability to assist with the ease of access to sampling points will be in the future a contribution to the Latin Hypercube Sampling (LHS) approach. By removing all locations in the initial instance from the DEM, the LHS model can be restricted to locations only with access from the adjacent road or trail. To further the approach, a road network geospatial dataset can be included within spatial Geographic Information Systems (GIS) applications to access already produced points using a shortest-distance network method.

  10. Field sampling, preparation procedure and plutonium analyses of large freshwater samples

    International Nuclear Information System (INIS)

    Straelberg, E.; Bjerk, T.O.; Oestmo, K.; Brittain, J.E.

    2002-01-01

    This work is part of an investigation of the mobility of plutonium in freshwater systems containing humic substances. A well-defined bog-stream system located in the catchment area of a subalpine lake, Oevre Heimdalsvatn, Norway, is being studied. During the summer of 1999, six water samples were collected from the tributary stream Lektorbekken and the lake itself. However, the analyses showed that the plutonium concentration was below the detection limit in all the samples. Therefore renewed sampling at the same sites was carried out in August 2000. The results so far are in agreement with previous analyses from the Heimdalen area. However, 100 times higher concentrations are found in the lowlands in the eastern part of Norway. The reason for this is not understood, but may be caused by differences in the concentrations of humic substances and/or the fact that the mountain areas are covered with snow for a longer period of time every year. (LN)

  11. Location, Location, Location: Does Place Provide the Opportunity for Differentiation for Universities?

    Science.gov (United States)

    Winter, Emma; Thompson-Whiteside, Helen

    2017-01-01

    The fiercely competitive HE market has led HEIs to invest significant resources in building a distinct identity. An HEI's location forms an inherent part of its identity and the uniqueness of location offers an opportunity to differentiate. However there has been limited examination of how location is used by HEIs and little consideration of how…

  12. Aflatoxin contamination of maize from different storage locations in Ghana

    International Nuclear Information System (INIS)

    Akrobortu, Dick Emmanuel

    2008-05-01

    The contamination of maize by aflatoxins in Ghana is of major concern because of the health hazards associated with it. This study focused on the role played by variations in climatic factors such as relative humidity and rainfall on aflatoxin contamination of maize in different maize storage locations. The study was carried out on samples collected over a period of 10 years (1990 to 1999) in three Districts (Ejura-Sekyedumase, Afram Plains/North-Kwahu and Nkoranza) well – known for maize production in Ghana. The aim was to study the influence of storage locations on levels of aflatoxin contamination and distribution in maize. The findings indicated that significant difference exists between the aflatoxin contamination levels of samples collected from Ejura-Sekyedumase and Nkoranza (p<0.05). Also there was a significant difference between the aflatoxin contamination levels of samples collected from Ejura-Sekyedumase and North-Kwahu (p<0.05). There was no significant difference between the contamination levels of samples from North- Kwahu and Nkoranza (p>0.05). The total aflatoxin levels in samples from Ejura-Sekyedumase, North-Kwahu and Nkoranza over the period were 120.50 ppb, 153.20 ppb and 134.17 ppb respectively. For the period 1990 to 1999 the aflatoxin distributions in the storage locations showed that Nkoranza had the highest level in 1997 and 1999 while North-Kwahu had the highest in 1990, 1991, 1993 and 1998. Similarly, Nkoranza and North-Kwahu had equal levels of 10.50 ppb in 1995. The three locations had equal levels of 9.50 ppb in 1994. On the whole, Ejura-Sekyedumase had fair distribution levels since it was the only location with its highest level far below the acceptable level of 20 ppb for humans. I hereby recommend that further research must be conducted in other districts in the country in order to create awareness of the health hazards associated with the aflatoxin contamination. (au)

  13. Tank 241-C-111 headspace gas and vapor sample results - August 1993 samples

    International Nuclear Information System (INIS)

    Huckaby, J.L.

    1994-01-01

    Tank 241-C-111 is on the ferrocyanide Watch List. Gas and vapor samples were collected to assure safe conditions before planned intrusive work was performed. Sample analyses showed that hydrogen is about ten times higher in the tank headspace than in ambient air. Nitrous oxide is about sixty times higher than ambient levels. The hydrogen cyanide concentration was below 0.04 ppbv, and the average NO x concentration was 8.6 ppmv

  14. Preanalytic Factors Associated With Hemolysis in Emergency Department Blood Samples.

    Science.gov (United States)

    Phelan, Michael P; Reineks, Edmunds Z; Schold, Jesse D; Hustey, Frederic M; Chamberlin, Janelle; Procop, Gary W

    2018-02-01

    - Hemolysis of emergency department blood samples is a common occurrence and has a negative impact on health care delivery. - To determine the effect of preanalytic factors (straight stick, intravenous [IV] line, needle gauge, location of blood draw, syringe versus vacuum tube use, tourniquet time) on hemolysis in emergency department blood samples. - A single 65 000-visit emergency department's electronic health record was queried for emergency department potassium results and blood draw technique for all samples obtained in calendar year 2014, resulting in 54 531 potassium results. Hemolyzed potassium was measured by hemolysis index. Comparisons of hemolysis by sampling technique were conducted by χ 2 tests. - Overall hemolysis was 10.0% (5439 of 54 531). Hemolysis among samples obtained from straight stick was significantly less than among those obtained with IV line (5.4% [33 of 615] versus 10.2% [4821 of 47 266], P < .001). For IV-placed blood draws, antecubital location had a statistically significant lower overall hemolysis compared with other locations: 7.4% (2117 of 28 786) versus 14.6% (2622 of 17 960) ( P < .001). For blood drawn with a syringe compared with vacuum, hemolysis was 13.0% (92 of 705) and 11.0% (1820 of 16 590), respectively ( P = .09, not significant). For large-gauge IV blood draws versus smaller-gauge IV lines, a lower hemolysis was also observed (9.3% [3882 of 41 571] versus 16.7% [939 of 5633]) ( P < .001). For IV-drawn blood with tourniquet time less than 60 seconds, hemolysis was 10.3% (1362 of 13 162) versus 13.9% for more than 60 seconds (532 of 3832), P < .001. - This study confirmed previous findings that straight stick and antecubital location are significantly associated with reduced hemolysis and indicated that shorter tourniquet time and larger gauge for IV draws were significantly associated with lower hemolysis.

  15. Network location theory and contingency planning

    Energy Technology Data Exchange (ETDEWEB)

    Hakimi, S L

    1983-08-01

    A brief survey of results in network location theory is first presented. Then, a systems view of contingency planning is described. Finally, some results in location theory are re-examined and it is shown that they are motivated by contingency planning considerations. Some new issues and problems in location theory are described, which, if properly tackled, will have a substantial impact on contingency planning in transportation.

  16. Scintigraphy and venous sampling in endocrine adrenal diseases. Clinical results in 85 patients

    International Nuclear Information System (INIS)

    Feltrin, G.P.; Maffessanti, M.; Miotto, D.; Mantero, F.; Macri, G.; Romani, S.

    1979-01-01

    The results obtained by adrenal scanning and venous sampling in 85 patients affected by various forms of adrenal pathology are reported and discussed. Pheochromocytoma rarely needs venous catheterization and blood sampling, since arteriography is almost always capable to visualize it. Scintigraphy alone is generally accurate enough to distinguish between bilateral hyperplasia and tumors in Cushing's and adrenogenital syndromes (100% of personal observations); only a tumoral situation benefits by venous catheterization. Blood samples and venography must be preceded by scintigraphy in Conn's syndrome

  17. Carotene location in processed food samples measured by cryo In-SEM Raman.

    Science.gov (United States)

    Lopez-Sanchez, Patricia; Schumm, Stephan; Pudney, Paul D A; Hazekamp, Johan

    2011-09-21

    Cryo In-SEM Raman has been used for the first time to localise carotene compounds in a food matrix. Raman spectra of lycopene and β-carotene have been obtained from sampling oil droplets and plant cell structures visualised with cryo-SEM in tomato and carrot based emulsions containing 5% oil. It was possible to identify the carotenoids in both the oil droplets and the cell walls. Furthermore our results gave some indication that the carotenoids were in the non-crystalline state. It has been suggested that a higher amount of carotenes solubilised into the oil phase of the food matrix would lead to a higher bioaccessibility, thus understanding the effect of processing conditions on micronutrients distribution in a food matrix might help the design of plant based food products with a better nutritional quality. This shows improved structural characterisation of the cryo-SEM with the molecular sensitivity of Raman spectroscopy as a promising approach for complex biological problems.

  18. Results for the first quarter calendar year 2017 tank 50H salt solution sample

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, C. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-04-12

    In this memorandum, the chemical and radionuclide contaminant results from the First Quarter Calendar Year 2017 (CY17) sample of Tank 50H salt solution are presented in tabulated form. The First Quarter CY17 Tank 50H samples [a 200 mL sample obtained 6” below the surface (HTF-50-17-7) and a 1 L sample obtained 66” from the tank bottom (HTF-50-17-8)] were obtained on January 15, 2017 and received at Savannah River National Laboratory (SRNL) on January 16, 2017. Prior to obtaining the samples from Tank 50H, a single pump was run at least 4.4 hours and the samples were pulled immediately after pump shut down. All volatile organic analysis (VOA) and semi-volatile organic analysis (SVOA) were performed on the surface sample and all other analyses were performed on the variable depth sample. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50H to the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility. This memorandum compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. The chemical and radionuclide contaminant results from the characterization of the First Quarter CY17 sampling of Tank 50H were requested by SRR personnel and details of the testing are presented in the SRNL Task Technical and Quality Assurance Plan (TTQAP). This memorandum is part of Deliverable 2 from SRR request. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the TTQAP for the Tank 50H saltstone task.

  19. Maintenance of tactile short-term memory for locations is mediated by spatial attention.

    Science.gov (United States)

    Katus, Tobias; Andersen, Søren K; Müller, Matthias M

    2012-01-01

    According to the attention-based rehearsal hypothesis, maintenance of spatial information is mediated by covert orienting towards memorized locations. In a somatosensory memory task, participants simultaneously received bilateral pairs of mechanical sample pulses. For each hand, sample stimuli were randomly assigned to one of three locations (fingers). A subsequent visual retro-cue determined whether the left or right hand sample was to be memorized. The retro-cue elicited lateralized activity reflecting the location of the relevant sample stimulus. Sensory processing during the retention period was probed by task-irrelevant pulses randomized to locations at the cued and uncued hand. The somatosensory N140 was enhanced for probes delivered to the cued hand, relative to uncued. Probes presented shortly after the retro-cue showed greatest attentional modulations. This suggests that transient contributions from retrospective selection overlapped with the sustained effect of attention-based rehearsal. In conclusion, focal attention shifts within tactile mnemonic content occurred after retro-cues and guided sensory processing during retention. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Hydraulic experiments on the failed fuel location module of prototype fast breeder reactor

    International Nuclear Information System (INIS)

    Rajesh, K.; Kumar, S.; Padmakumar, G.; Prakash, V.; Vijayashree, R.; Rajan Babu, V.; Govinda Rajan, S.; Vaidyanathan, G.; Prabhaker, R.

    2003-01-01

    The design of Prototype Fast Breeder Reactor (PFBR) is based on sound design concepts with emphasis on intrinsic safety. The uncertainties involved in the design of various components, which are difficult to assess theoretically, are experimentally verified before design is validated. In PFBR core, the coolant (liquid sodium) enters the bottom of the fuel subassembly, passes over the fuel pins picking up the fission heat and issues in to a hot pool. If there is any breach in the fuel pins, the fission products come in direct contact with the coolant. This is undesirable and it is necessary to locate the subassembly with the failed fuel pin and to isolate it. A component called Failed Fuel Location Module (FFLM) is employed for locating the failed SA by monitoring the coolant samples coming out of each Subassembly. The coolant sample from each Subassembly is drawn by FFLM using an EM pump through sampling tube and selector valve and is monitored for the presence of delayed neutrons which is an indication of failure of the Subassembly. The pressure drop across the selector valve determines the rating of the EM Pump. The dilution of the coolant sample across the selector valve determines the effectiveness of monitoring for contamination. It is not possible to predict pressure drop across the selector valve and dilution of the coolant sample theoretically. These two parameters are determined using a hydraulic experiment on the FFLM. The experiment was carried out in conditions that simulate the reactor conditions following appropriate similarity laws. The paper discusses the details of the model, techniques of experiments and the results from the studies

  1. Common Nearly Best Linear Estimates of Location and Scale ...

    African Journals Online (AJOL)

    Common nearly best linear estimates of location and scale parameters of normal and logistic distributions, which are based on complete samples, are considered. Here, the population from which the samples are drawn is either normal or logistic population or a fusion of both distributions and the estimates are computed ...

  2. Solvent hold tank sample results for MCU-16-1363-1365. November 2016 monthly sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-03-22

    Savannah River National Laboratory (SRNL) received one set of three Solvent Hold Tank (SHT) samples (MCU-16-1363-1364-1365), pulled on 11/15/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1363-1364-1365 indicated the Isopar™L concentration is at its nominal level (100%). The extractant (MaxCalix) and the modifier (CS- 7SB) are 8% and 2 % below their nominal concentrations. The suppressor (TiDG) is 7% below its nominal concentration. This analysis confirms the trim and Isopar™ additions to the solvent in November. This analysis also indicates the solvent did not require further additions. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended.

  3. Technology for home dementia care: A prototype locating system put to the test.

    Science.gov (United States)

    Megges, Herlind; Freiesleben, Silka Dawn; Jankowski, Natalie; Haas, Brigitte; Peters, Oliver

    2017-09-01

    The user experience of persons with dementia and their primary caregivers with locating systems is not firmly established. Eighteen dyads used a prototype locating system during 4 weeks. Primary outcome measures were ratings of usability, and product functions and features. Secondary outcome measures were caregiver burden, perceived self-efficacy, frequency of use, and willingness to purchase the prototype. Changes in scores between baseline (T 1 ) and end of testing period (T 2 ) were compared by performing independent and dependent samples correlations and descriptive statistics. Seventeen dyads made up the final sample. Ratings of usability and product functions and features were fair, but usability ratings were significantly reduced after 4 weeks. Although the prototype was used infrequently by majority of the participants, most caregivers would be willing to purchase the prototype, with men more willing than women. No significant change in technological willingness, caregiver burden, or perceived self-efficacy was found between T 1 and T 2 . Perceived self-efficacy significantly negatively correlated with willingness to purchase the prototype after 4 weeks. Results highlight the importance of including end users in the research and development phase of locating systems to improve the user experience in home dementia care. Necessary indications for further research are carrying out randomized controlled trials with larger, more representative samples and developing innovative software and hardware solutions.

  4. Groundwater-quality data in 12 GAMA study units: Results from the 2006–10 initial sampling period and the 2008–13 trend sampling period, California GAMA Priority Basin Project

    Science.gov (United States)

    Mathany, Timothy M.

    2017-03-09

    The Priority Basin Project (PBP) of the Groundwater Ambient Monitoring and Assessment (GAMA) program was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey in cooperation with the California State Water Resources Control Board. From 2004 through 2012, the GAMA-PBP collected samples and assessed the quality of groundwater resources that supply public drinking water in 35 study units across the State. Selected sites in each study unit were sampled again approximately 3 years after initial sampling as part of an assessment of temporal trends in water quality by the GAMA-PBP. Twelve of the study units, initially sampled during 2006–11 (initial sampling period) and sampled a second time during 2008–13 (trend sampling period) to assess temporal trends, are the subject of this report.The initial sampling was designed to provide a spatially unbiased assessment of the quality of untreated groundwater used for public water supplies in the 12 study units. In these study units, 550 sampling sites were selected by using a spatially distributed, randomized, grid-based method to provide spatially unbiased representation of the areas assessed (grid sites, also called “status sites”). After the initial sampling period, 76 of the previously sampled status sites (approximately 10 percent in each study unit) were randomly selected for trend sampling (“trend sites”). The 12 study units sampled both during the initial sampling and during the trend sampling period were distributed among 6 hydrogeologic provinces: Coastal (Northern and Southern), Transverse Ranges and Selected Peninsular Ranges, Klamath, Modoc Plateau and Cascades, and Sierra Nevada Hydrogeologic Provinces. For the purposes of this trend report, the six hydrogeologic provinces were grouped into two hydrogeologic regions based on location: Coastal and Mountain.The groundwater samples were analyzed for a number of synthetic organic

  5. Continuous wavelet transform analysis and modal location analysis acoustic emission source location for nuclear piping crack growth monitoring

    International Nuclear Information System (INIS)

    Shukri Mohd

    2013-01-01

    Full-text: Source location is an important feature of acoustic emission (AE) damage monitoring in nuclear piping. The ability to accurately locate sources can assist in source characterisation and early warning of failure. This paper describe the development of a novelAE source location technique termed Wavelet Transform analysis and Modal Location (WTML) based on Lamb wave theory and time-frequency analysis that can be used for global monitoring of plate like steel structures. Source location was performed on a steel pipe of 1500 mm long and 220 mm outer diameter with nominal thickness of 5 mm under a planar location test setup using H-N sources. The accuracy of the new technique was compared with other AE source location methods such as the time of arrival (TOA) technique and DeltaTlocation. The results of the study show that the WTML method produces more accurate location results compared with TOA and triple point filtering location methods. The accuracy of the WTML approach is comparable with the deltaT location method but requires no initial acoustic calibration of the structure. (author)

  6. 78 FR 79009 - Proposed Information Collection; Radiation Sampling and Exposure Records (Pertains to Underground...

    Science.gov (United States)

    2013-12-27

    ... soliciting comments concerning the proposed information collection for updating Radiation Sampling and... exposed with no adverse effects have been established and are expressed as working levels (WL). The... mandatory samplings. Records must include the sample date, location, and results, and must be retained at...

  7. Results For The Third Quarter Calendar Year 2016 Tank 50H Salt Solution Sample

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-10-13

    In this memorandum, the chemical and radionuclide contaminant results from the Third Quarter Calendar Year 2016 (CY16) sample of Tank 50H salt solution are presented in tabulated form. The Third Quarter CY16 Tank 50H samples (a 200 mL sample obtained 6” below the surface (HTF-5-16-63) and a 1 L sample obtained 66” from the tank bottom (HTF-50-16-64)) were obtained on July 14, 2016 and received at Savannah River National Laboratory (SRNL) on the same day. Prior to obtaining the samples from Tank 50H, a single pump was run at least 4.4 hours, and the samples were pulled immediately after pump shut down. The information from this characterization will be used by Defense Waste Processing Facility (DWPF) & Saltstone Facility Engineering for the transfer of aqueous waste from Tank 50H to the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility. This memorandum compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the Task Technical and Quality Assurance Plan (TTQAP) for the Tank 50H saltstone task. The chemical and radionuclide contaminant results from the characterization of the Third Quarter CY16 sampling of Tank 50H were requested by Savannah River Remediation (SRR) personnel and details of the testing are presented in the SRNL TTQAP.

  8. Assessing representativeness of sampling methods for reaching men who have sex with men: a direct comparison of results obtained from convenience and probability samples.

    Science.gov (United States)

    Schwarcz, Sandra; Spindler, Hilary; Scheer, Susan; Valleroy, Linda; Lansky, Amy

    2007-07-01

    Convenience samples are used to determine HIV-related behaviors among men who have sex with men (MSM) without measuring the extent to which the results are representative of the broader MSM population. We compared results from a cross-sectional survey of MSM recruited from gay bars between June and October 2001 to a random digit dial telephone survey conducted between June 2002 and January 2003. The men in the probability sample were older, better educated, and had higher incomes than men in the convenience sample, the convenience sample enrolled more employed men and men of color. Substance use around the time of sex was higher in the convenience sample but other sexual behaviors were similar. HIV testing was common among men in both samples. Periodic validation, through comparison of data collected by different sampling methods, may be useful when relying on survey data for program and policy development.

  9. Direct sampling methods for inverse elastic scattering problems

    Science.gov (United States)

    Ji, Xia; Liu, Xiaodong; Xi, Yingxia

    2018-03-01

    We consider the inverse elastic scattering of incident plane compressional and shear waves from the knowledge of the far field patterns. Specifically, three direct sampling methods for location and shape reconstruction are proposed using the different component of the far field patterns. Only inner products are involved in the computation, thus the novel sampling methods are very simple and fast to be implemented. With the help of the factorization of the far field operator, we give a lower bound of the proposed indicator functionals for sampling points inside the scatterers. While for the sampling points outside the scatterers, we show that the indicator functionals decay like the Bessel functions as the sampling point goes away from the boundary of the scatterers. We also show that the proposed indicator functionals continuously dependent on the far field patterns, which further implies that the novel sampling methods are extremely stable with respect to data error. For the case when the observation directions are restricted into the limited aperture, we firstly introduce some data retrieval techniques to obtain those data that can not be measured directly and then use the proposed direct sampling methods for location and shape reconstructions. Finally, some numerical simulations in two dimensions are conducted with noisy data, and the results further verify the effectiveness and robustness of the proposed sampling methods, even for multiple multiscale cases and limited-aperture problems.

  10. Quantifying geocode location error using GIS methods

    Directory of Open Access Journals (Sweden)

    Gardner Bennett R

    2007-04-01

    Full Text Available Abstract Background The Metropolitan Atlanta Congenital Defects Program (MACDP collects maternal address information at the time of delivery for infants and fetuses with birth defects. These addresses have been geocoded by two independent agencies: (1 the Georgia Division of Public Health Office of Health Information and Policy (OHIP and (2 a commercial vendor. Geographic information system (GIS methods were used to quantify uncertainty in the two sets of geocodes using orthoimagery and tax parcel datasets. Methods We sampled 599 infants and fetuses with birth defects delivered during 1994–2002 with maternal residence in either Fulton or Gwinnett County. Tax parcel datasets were obtained from the tax assessor's offices of Fulton and Gwinnett County. High-resolution orthoimagery for these counties was acquired from the U.S. Geological Survey. For each of the 599 addresses we attempted to locate the tax parcel corresponding to the maternal address. If the tax parcel was identified the distance and the angle between the geocode and the residence were calculated. We used simulated data to characterize the impact of geocode location error. In each county 5,000 geocodes were generated and assigned their corresponding Census 2000 tract. Each geocode was then displaced at a random angle by a random distance drawn from the distribution of observed geocode location errors. The census tract of the displaced geocode was determined. We repeated this process 5,000 times and report the percentage of geocodes that resolved into incorrect census tracts. Results Median location error was less than 100 meters for both OHIP and commercial vendor geocodes; the distribution of angles appeared uniform. Median location error was approximately 35% larger in Gwinnett (a suburban county relative to Fulton (a county with urban and suburban areas. Location error occasionally caused the simulated geocodes to be displaced into incorrect census tracts; the median percentage

  11. Results from tests of TFL Hydragard sampling loop

    International Nuclear Information System (INIS)

    Steimke, J.L.

    1995-03-01

    When the Defense Waste Processing Facility (DWPF) is operational, processed radioactive sludge will be transferred in batches to the Slurry Mix Evaporator (SME), where glass frit will be added and the contents concentrated by boiling. Batches of the slurry mixture are transferred from the SME to the Melter Feed Tank (MFT). Hydragard reg-sign sampling systems are used on the SME and the MFT for collecting slurry samples in vials for chemical analysis. An accurate replica of the Hydragard sampling system was built and tested in the thermal Fluids Laboratory (TFL) to determine the hydragard accuracy. It was determined that the original Hydragard valve frequently drew a non-representative sample stream through the sample vial that ranged from frit enriched to frit depleted. The Hydragard valve was modified by moving the plunger and its seat backwards so that the outer surface of the plunger was flush with the inside diameter of the transfer line when the valve was open. The slurry flowing through the vial accurately represented the composition of the slurry in the reservoir for two types of slurries, different dilution factors, a range of transfer flows and a range of vial flows. It was then found that the 15 ml of slurry left in the vial when the Hydragard valve was closed, which is what will be analyzed at DWPF, had a lower ratio of frit to sludge as characterized by the lithium to iron ratio than the slurry flowing through it. The reason for these differences is not understood at this time but it is recommended that additional experimentation be performed with the TFL Hydragard loop to determine the cause

  12. Study of Coal Burst Source Locations in the Velenje Colliery

    Directory of Open Access Journals (Sweden)

    Goran Vižintin

    2016-06-01

    Full Text Available The Velenje coal mine (VCM is situated on the largest Slovenian coal deposit and in one of the thickest layers of coal known in the world. The thickness of the coal layer causes problems for the efficiency of extraction, since the majority of mining operations is within the coal layer. The selected longwall coal mining method with specific geometry, increasing depth of excavations, changes in stress state and naturally given geomechanical properties of rocks induce seismic events. Induced seismic events can be caused by caving processes, blasting or bursts of coal or the surrounding rock. For 2.5D visualization, data of excavations, ash content and calorific value of coal samples, hanging wall and footwall occurrence, subsidence of the surface and coal burst source locations were collected. Data and interpolation methods available in software package Surfer®12 were statistically analyzed and a Kriging (KRG interpolation method was chosen. As a result 2.5D visualizations of coal bursts source locations with geomechanical properties of coal samples taken at different depth in the coal seam in the VCM were made with data-visualization packages Surfer®12 and Voxler®3.

  13. Solvent Hold Tank Sample Results for MCU-16-934-935-936: June 2016 Monthly Sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-08-30

    Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-934-935-936), pulled on 07/01/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-934-935-936 indicated the Isopar™L concentration is above its nominal level (101%). The modifier (CS-7SB) and the TiDG concentrations are 8% and 29 % below their nominal concentrations. This analysis confirms the solvent may require the addition of TiDG, and possibly of modifier. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). However, up to 21.1 ± 4 micrograms of mercury per gram of solvent (or 17.5 μg/mL) was detected in this sample (as determined by the XRF method of undigested sample). The current gamma level (1.41E5 dpm/mL) confirmed that the gamma concentration has returned to previous levels (as observed in the late 2015 samples) where the process operated normally and as expected.

  14. Tremor Source Location at Okmok Volcano

    Science.gov (United States)

    Reyes, C. G.; McNutt, S. R.

    2007-12-01

    Initial results using an amplitude-based tremor location program have located several active tremor episodes under Cone A, a vent within Okmok volcano's 10 km caldera. Okmok is an andesite volcano occupying the north-eastern half of Umnak Island, in the Aleutian islands. Okmok is defined by a ~2000 y.b.p. caldera that contains multiple cinder cones. Cone A, the youngest of these, extruded lava in 1997 covering the caldera floor. Since April 2003, continuous seismic data have been recorded from eight vertical short-period stations (L4-C's) installed at distances from Cone A ranging from 2 km to 31 km. In 2004 four additional 3- component broadband stations were added, co-located with continuous GPS stations. InSAR and GPS measurements of post-eruption deformation show that Okmok experienced several periods of rapid inflation (Mann and Freymueller, 2002), from the center of the 10 km diameter caldera. While there are few locatable VT earthquakes, there has been nearly continuous low-level tremor with stronger amplitude bursts occurring at variable rates and durations. The character of occurrence remained relatively constant over the course of days to weeks until the signal ceased in mid 2005. Within any day, tremor behavior remains fairly consistent, with bursts closely resembling each other, suggesting a single main process or source location. The tremor is composed of irregular waves with a broad range of frequencies, though most energy resides between ~2 Hz and 6 Hz. Attempts to locate the tremor using traditional arrival time methods fail because the signal is emergent, with envelopes too ragged to correlate on time scales that hold much hope for a location. Instead, focus was shifted to the amplitude ratios at various stations. Candidates for the tremor source include the center of inflation and Cone A, 3 km to the south-west. For all dates on record, data were band pass filtered between 1 and 5 Hz, then evaluated in 20.48 second windows (N=2048, sampling rate

  15. Sample Return Robot

    Data.gov (United States)

    National Aeronautics and Space Administration — This Challenge requires demonstration of an autonomous robotic system to locate and collect a set of specific sample types from a large planetary analog area and...

  16. 60-Day waste compatibility safety issues and final results for AY-102 grab samples

    Energy Technology Data Exchange (ETDEWEB)

    Nuzum, J.L.

    1997-01-31

    Four grab samples (2AY-96-15, 2AY-96-16, 2AY-96-17, and 2AY-96-18) were taken from Riser 15D of Tank 241-AY-102 on October 8, 1996, and received by 222-S Laboratory on October 8, 1996. These samples were analyzed in accordance with Compatibility Grab Sampling and Analysis Plan (TSAP) and Data Quality Objectives for Tank Farms Waste Compatibility Program (DQO) in support of the Waste Compatibility Program. No notifications were required based on sample results.

  17. Does location congruence matter? : a field study on the effects of location based advertising on perceived adintrusiveness, relevance and value

    NARCIS (Netherlands)

    Hühn, A.E.; Khan, J.V.; Ketelaar, P.; van t Riet, J.J.; Batalas, N.; König, R.; Rozendaal, E.; Markopoulos, P.

    2017-01-01

    We investigate the effect of location-congruent mobile messages on perceived intrusiveness, value, and relevance through a field experiment using the Experience Sampling Method (ESM). We developed a mobile application for undergraduate students, featuring campus news and information concerning class

  18. Does location congruence matter? A field study on the effects of location-based advertising on perceived AD intrusiveness, relevance & value

    NARCIS (Netherlands)

    Hühn, A.E.; Khan, V.J.; Ketelaar, P.E.; Riet, J.P. van 't; Konig, R.P.; Rozendaal, E.; Batalas, N.; Markopoulos, P.

    2017-01-01

    We investigate the effect of location-congruent mobile messages on perceived intrusiveness, value, and relevance through a field experiment using the Experience Sampling Method (ESM). We developed a mobile application for undergraduate students, featuring campus news and information concerning class

  19. Determination of Sr-90 in milk samples from the study of statistical results

    Directory of Open Access Journals (Sweden)

    Otero-Pazos Alberto

    2017-01-01

    Full Text Available The determination of 90Sr in milk samples is the main objective of radiation monitoring laboratories because of its environmental importance. In this paper the concentration of activity of 39 milk samples was obtained through radiochemical separation based on selective retention of Sr in a cationic resin (Dowex 50WX8, 50-100 mesh and subsequent determination by a low-level proportional gas counter. The results were checked by performing the measurement of the Sr concentration by using the flame atomic absorption spectroscopy technique, to finally obtain the mass of 90Sr. From the data obtained a statistical treatment was performed using linear regressions. A reliable estimate of the mass of 90Sr was obtained based on the gravimetric technique, and secondly, the counts per minute of the third measurement in the 90Sr and 90Y equilibrium, without having to perform the analysis. These estimates have been verified with 19 milk samples, obtaining overlapping results. The novelty of the manuscript is the possibility of determining the concentration of 90Sr in milk samples, without the need to perform the third measurement in the equilibrium.

  20. Results of Remediation and Verification Sampling for the 600-270 Horseshoe Landfill

    Energy Technology Data Exchange (ETDEWEB)

    W. S. Thompson

    2005-12-14

    This report presents the results of the 2005 remedial action and verification soil sampling conducted at the 600-270 waste site after removal of soil containing residual concentrations of dichlorodiphenyl trichloroethane and its breakdown products dichlorodiphenyl dichloroethylene and dichlorodiphenyl dichloroethane. The remediation was performed in response to post-closure surface soil sampling performed between 1998 and 2003 that indicated the presence of residual DDT contamination exceeding the Record of Decision for the 1100 Area National Priorities List site cleanup criteria of 1 mg/kg that was established for the original 1994 cleanup activities.

  1. Results of Remediation and Verification Sampling for the 600-270 Horseshoe Landfill

    International Nuclear Information System (INIS)

    Thompson, W.S.

    2005-01-01

    This report presents the results of the 2005 remedial action and verification soil sampling conducted at the 600-270 waste site after removal of soil containing residual concentrations of dichlorodiphenyl trichloroethane and its breakdown products dichlorodiphenyl dichloroethylene and dichlorodiphenyl dichloroethane. The remediation was performed in response to post-closure surface soil sampling performed between 1998 and 2003 that indicated the presence of residual DDT contamination exceeding the Record of Decision for the 1100 Area National Priorities List site cleanup criteria of 1 mg/kg that was established for the original 1994 cleanup activities.

  2. Lattice location of diffused Zn atoms in GaAs and InP single crystals

    International Nuclear Information System (INIS)

    Chan, L.Y.; Yu, K.M.; Ben-Tzur, M.; Haller, E.E.; Jaklevic, J.M.; Walukiewicz, W.; Hanson, C.M.

    1991-01-01

    We have investigated the saturation phenomenon of the free carrier concentration in p-type GaAs and InP single crystals doped by zinc diffusion. The free hole saturation occurs at 10 20 cm -3 for GaAs, but the maximum concentration for InP appears at mid 10 18 cm -3 . The difference in the saturation hole concentrations for these materials is investigated by studying the incorporation and the lattice location of the impurity zinc, an acceptor when located on a group III atom site. Zinc is diffused into the III-V wafers in a sealed quartz ampoule. Particle-induced x-ray emission with ion-channeling techniques are employed to determine the exact lattice location of the zinc atoms. We have found that over 90% of all zinc atoms occupy Ga sites in the diffused GaAs samples, while for the InP case, the zinc substitutionality is dependent on the cooling rate of the sample after high-temperature diffusion. For the slowly cooled sample, a large fraction (∼90%) of the zinc atoms form random precipitates of Zn 3 P 2 and elemental Zn. However, when rapidly cooled only 60% of the zinc forms such precipitates while the rest occupies specific sites in the InP. We analyze our results in terms of the amphoteric native defect model. We show that the difference in the electrical activity of the Zn atoms in GaAs and InP is a consequence of the different location of the Fermi level stabilization energy in these two materials

  3. A study of toxic emissions from a coal-fired power plant utilizing an ESP/Wet FGD system. Volume 1, Sampling, results, and special topics: Final report

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    This was one of a group of assessments of toxic emissions from coal-fired power plants, conducted for DOE-PETC in 1993 as mandated by the 1990 Clean Air Act. It is organized into 2 volumes; Volume 1 describes the sampling effort, presents the concentration data on toxic chemicals in several power plant streams, and reports the results of evaluations and calculations. The study involved solid, liquid, and gaseous samples from input, output, and process streams at Coal Creek Station Unit No. 1, Underwood, North Dakota (1100 MW mine-mouth plant burning lignite from the Falkirk mine located adjacent to the plant). This plant had an electrostatic precipitator and a wet scrubber flue gas desulfurization unit. Measurements were conducted on June 21--24, 26, and 27, 1993; chemicals measured were 6 major and 16 trace elements (including Hg, Cr, Cd, Pb, Se, As, Be, Ni), acids and corresponding anions (HCl, HF, chloride, fluoride, phosphate, sulfate), ammonia and cyanide, elemental C, radionuclides, VOCs, semivolatiles (incl. PAH, polychlorinated dioxins, furans), and aldehydes. Volume 2: Appendices includes process data log sheets, field sampling data sheets, uncertainty calculations, and quality assurance results.

  4. ISOLOK VALVE ACCEPTANCE TESTING FOR DWPF SME SAMPLING PROCESS

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, T.; Hera, K.; Coleman, C.; Jones, M.; Wiedenman, B.

    2011-12-05

    Evaluation of the Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) cycle time identified several opportunities to improve the CPC processing time. Of the opportunities, a focus area related to optimizing the equipment and efficiency of the sample turnaround time for DWPF Analytical Laboratory was identified. The Mechanical Systems & Custom Equipment Development (MS&CED) Section of the Savannah River National Laboratory (SRNL) evaluated the possibility of using an Isolok{reg_sign} sampling valve as an alternative to the Hydragard{reg_sign} valve for taking process samples. Previous viability testing was conducted with favorable results using the Isolok sampler and reported in SRNL-STI-2010-00749 (1). This task has the potential to improve operability, reduce maintenance time and decrease CPC cycle time. This report summarizes the results from acceptance testing which was requested in Task Technical Request (TTR) HLW-DWPF-TTR-2010-0036 (2) and which was conducted as outlined in Task Technical and Quality Assurance Plan (TTQAP) SRNL-RP-2011-00145 (3). The Isolok to be tested is the same model which was tested, qualified, and installed in the Sludge Receipt Adjustment Tank (SRAT) sample system. RW-0333P QA requirements apply to this task. This task was to qualify the Isolok sampler for use in the DWPF Slurry Mix Evaporator (SME) sampling process. The Hydragard, which is the current baseline sampling method, was used for comparison to the Isolok sampling data. The Isolok sampler is an air powered grab sampler used to 'pull' a sample volume from a process line. The operation of the sampler is shown in Figure 1. The image on the left shows the Isolok's spool extended into the process line and the image on the right shows the sampler retracted and then dispensing the liquid into the sampling container. To determine tank homogeneity, a Coliwasa sampler was used to grab samples at a high and low location within the mixing tank. Data from

  5. Statistical sampling strategies for survey of soil contamination

    NARCIS (Netherlands)

    Brus, D.J.

    2011-01-01

    This chapter reviews methods for selecting sampling locations in contaminated soils for three situations. In the first situation a global estimate of the soil contamination in an area is required. The result of the surey is a number or a series of numbers per contaminant, e.g. the estimated mean

  6. Gamma spectroscopy analysis of archived Marshall Island soil samples

    International Nuclear Information System (INIS)

    Herman, S.; Hoffman, K.; Lavelle, K.; Trauth, A.; Glover, S.E.; Connick, W.; Spitz, H.; LaMont, S.P.; Hamilton, T.

    2016-01-01

    Four samples of archival Marshall Islands soil were subjected to non-destructive, broad energy (17 keV-2.61 MeV) gamma-ray spectrometry analysis using a series of different high-resolution germanium detectors. These archival samples were collected in 1967 from different locations on Bikini Atoll and were contaminated with a range of fission and activation products, and other nuclear material from multiple weapons tests. Unlike samples collected recently, these samples have been stored in sealed containers and have been unaffected by approximately 50 years of weathering. Initial results show that the samples contained measurable but proportionally different concentrations of plutonium, 241 Am, and 137 Cs, and 60 Co. (author)

  7. Cadmium and lead contamination in japonica rice grains and its variation among the different locations in southeast China

    International Nuclear Information System (INIS)

    Cheng Fangmin; Zhao Ningchun; Xu Haiming; Li Yi; Zhang Wenfang; Zhu Zhiwei; Chen Mingxue

    2006-01-01

    On the basis of a large-scale survey with 269 sampling sites and a field experiment with 12 cultivars grown at 3 ecologically different locations, Cadmium (Cd) and lead (Pb) contamination in milled rice grains and its variation among different locations were investigated in the area of southeast China. The objective of this study was mainly to assess the present situation of Cd and Pb contamination in rice grains harvested locally and find out the variation of Cd and Pb background levels in rice grains among the diverse regional locations. The results showed that: a) Cd concentrations in milled rice grains ranged from trace (below 10 ng/g) to 340 ng/g, with the means of 81.4 ng/g (AM) and 55.2 ng/g (GM) for the 269 samples, whereas Pb concentrations ranged from trace (below 10 ng/g) to 1136 ng/g, with the means of 113.5 ng/g (AM) and 51.0 ng/g (GM), respectively. High frequency was observed for both the Cd and Pb concentrations ranging from trace to 200 ng/g, with 95.9% for Cd and 84.8% for Pb, respectively. b) ANOVA for the AMs and GMs among 269 sampling sites indicated that there were significant differences among the different spatial locations in Cd or Pb concentrations. c) The Cd concentrations in milled rice grains were poorly correlated with Pb concentration among the 269 sampling sites surveyed, and no significant difference (P > 0.05) in the AMs or GMs of Cd and Pb concentration was observed among different cities within a range of the same provinces, only with an exception for 1-2 provinces. d) Variance analysis of Cd, Pb concentrations for 12 rice cultivars grown in three locations showed that the great difference in coefficients of variation (CV) was observed both among cultivars grown in the same location and among locations of cultivars planted, in which locations showed much more contribution to the variation of Cd or Pb concentration in milled rice grains as compared with cultivars

  8. Results of initial analyses of the salt (macro) batch 11 Tank 21H qualification samples

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-10-23

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Interim Salt Disposition Project (ISDP) Salt (Macro) Batch 11 for processing through the Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU). This document reports the initial results of the analyses of samples of Tank 21H. Analysis of the Tank 21H Salt (Macro) Batch 11 composite sample indicates that the material does not display any unusual characteristics or observations, such as floating solids, the presence of large amounts of solids, or unusual colors. Further sample results will be reported in a future document. This memo satisfies part of Deliverable 3 of the Technical Task Request (TTR).

  9. Low-sampling-rate ultra-wideband channel estimation using equivalent-time sampling

    KAUST Repository

    Ballal, Tarig

    2014-09-01

    In this paper, a low-sampling-rate scheme for ultra-wideband channel estimation is proposed. The scheme exploits multiple observations generated by transmitting multiple pulses. In the proposed scheme, P pulses are transmitted to produce channel impulse response estimates at a desired sampling rate, while the ADC samples at a rate that is P times slower. To avoid loss of fidelity, the number of sampling periods (based on the desired rate) in the inter-pulse interval is restricted to be co-prime with P. This condition is affected when clock drift is present and the transmitted pulse locations change. To handle this case, and to achieve an overall good channel estimation performance, without using prior information, we derive an improved estimator based on the bounded data uncertainty (BDU) model. It is shown that this estimator is related to the Bayesian linear minimum mean squared error (LMMSE) estimator. Channel estimation performance of the proposed sub-sampling scheme combined with the new estimator is assessed in simulation. The results show that high reduction in sampling rate can be achieved. The proposed estimator outperforms the least squares estimator in almost all cases, while in the high SNR regime it also outperforms the LMMSE estimator. In addition to channel estimation, a synchronization method is also proposed that utilizes the same pulse sequence used for channel estimation. © 2014 IEEE.

  10. Explaining preferences for home surroundings and locations

    DEFF Research Database (Denmark)

    Andersen, Hans Skifter

    2011-01-01

    This article is based on a survey carried out in Denmark that asked a random sample of the population about their preferences for home surroundings and locations. It shows that the characteristics of social surroundings are very important and can be divided into three independent dimensions......: avoiding social nuisances, preferring social homogeneity and living close to one’s social network and place of origin. The study shows that most people have many detailed preferences, whereas some have very few. This confirms an earlier theory that some people are very connected to certain places...... with given characteristics and thus do not have priorities regarding home surroundings and locations. For others, mostly young people and singles, home is just a place to sleep and relax, whereas life is lived elsewhere. For this group, there are only preferences for location and there are few specific...

  11. [Location selection for Shenyang urban parks based on GIS and multi-objective location allocation model].

    Science.gov (United States)

    Zhou, Yuan; Shi, Tie-Mao; Hu, Yuan-Man; Gao, Chang; Liu, Miao; Song, Lin-Qi

    2011-12-01

    Based on geographic information system (GIS) technology and multi-objective location-allocation (LA) model, and in considering of four relatively independent objective factors (population density level, air pollution level, urban heat island effect level, and urban land use pattern), an optimized location selection for the urban parks within the Third Ring of Shenyang was conducted, and the selection results were compared with the spatial distribution of existing parks, aimed to evaluate the rationality of the spatial distribution of urban green spaces. In the location selection of urban green spaces in the study area, the factor air pollution was most important, and, compared with single objective factor, the weighted analysis results of multi-objective factors could provide optimized spatial location selection of new urban green spaces. The combination of GIS technology with LA model would be a new approach for the spatial optimizing of urban green spaces.

  12. 45-Day safety screen results for Tank 241-C-101, auger sample 95-AUG-019

    International Nuclear Information System (INIS)

    Sasaki, L.M.

    1995-01-01

    One auger sample from Tank 241-C-101 was received by the 222-S Laboratory and underwent safety screening analyses--differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and total alpha analysis--in accordance with the tank characterization plan. Analytical results for the TGA on the crust sample (the uppermost portion of the auger sample) (sample number S95T000823) were less than the safety screening notification limit of 17 weight percent water. Verbal and written notifications were made on May 3, 1995. No exotherms were observed in the DSC analyses and the total alpha results were well below the safety screening notification limit. This report includes the primary safety screening results obtained from the analyses and copies of all DSC and TGA raw data scans as requested per the TCP. Although not included in this report, a photograph of the extruded sample was taken and is available. This report also includes bulk density measurements required by Characterization Plant Engineering. Additional analyses (pH, total organic carbon, and total inorganic carbon) are being performed on the drainable liquid at the request of Characterization Process Control; these analyses will be reported at a later date in a final report for this auger sample. Tank C-101 is not part of any of the four Watch Lists

  13. Simulation analysis for hyperbola locating accuracy

    International Nuclear Information System (INIS)

    Wang Changli; Liu Daizhi

    2004-01-01

    In the system of the hyperbola location, the geometric shape of the detecting stations has an important influence on the locating accuracy. At first, this paper simulates the process of the hyperbola location by the computer, and then analyzes the influence of the geometric shape on the locating errors and gives the computer simulation results, finally, discusses the problems that require attention in course of selecting the detecting station. The conclusion has practicality. (authors)

  14. PRTR ion exchange vault column sampling

    International Nuclear Information System (INIS)

    Cornwell, B.C.

    1995-01-01

    This report documents ion exchange column sampling and Non Destructive Assay (NDA) results from activities in 1994, for the Plutonium Recycle Test Reactor (PRTR) ion exchange vault. The objective was to obtain sufficient information to prepare disposal documentation for the ion exchange columns found in the PRTR Ion exchange vault. This activity also allowed for the monitoring of the liquid level in the lower vault. The sampling activity contained five separate activities: (1) Sampling an ion exchange column and analyzing the ion exchange media for purpose of waste disposal; (2) Gamma and neutron NDA testing on ion exchange columns located in the upper vault; (3) Lower vault liquid level measurement; (4) Radiological survey of the upper vault; and (5) Secure the vault pending waste disposal

  15. Long-term effects of OBM cutting discharges at 12 locations on the Dutch continental shelf

    International Nuclear Information System (INIS)

    Daan, R.; Mulder, M.

    1996-01-01

    A sampling programme was carried out in 1994 and 1995 covering 12 well sites where OBM cuttings had been discharged 7 to 13 years ago. The locations were selected in areas with different sediment types. In terms of amounts of base oil discharged the discharge loads ranged from 13 to 298 tonnes. The locations included actual production platforms but also abandoned well sites. At each location compendious surveys were carried out, during which 4 stations were sampled at distances between 100 and 2000m from the discharge site. Sediment samples for chemical analysis were collected at all stations and numbers of the OBM-sensitive species Echinocardium cordatum were counted in all samples. Additional macrofauna analyses were performed for 5 locations. The chemical analyses revealed elevated oil concentrations at 5 of the 12 locations, but traces of oil were visually observed in a few samples at another 2 locations. Maximum concentrations, measured over the upper 10 cm layer, were generally in the order of 10-50 mg/kg dry sediment, but at one location a concentration of 200 mg/kg was found, which is comparable to the values found at formerly investigated locations L4-a and P6-b, but considerably lower than at K12-a. This indicates that concentration levels at most locations are generally not as high as found at the locations formerly investigated. Except for one location where oil was found up to 250m from the platform, elevated oil concentrations in surface sediments only occurred at 100m stations. Significant effects on the population densities of E. cordatum were found at 7 of the 12 locations. Further, at 2 locations the abundance pattern of the species was indicative of an effect but there was no statistical significance. Population densities of E. cordaturn appeared to be depressed in the vicinity of two locations where no oil was detected. This indicates that the absence of oil in samples does not necessarily mean that sediment conditions have completely recovered

  16. Solvent Hold Tank Sample Results for MCU-16-596-597-598: April 2016 Monthly Sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL). Advanced Characterization and Processing; Jones, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL). Research Support

    2016-07-12

    Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-596-597-598), pulled on 04/30/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-596-597-598 indicated the Isopar™L concentration is above its nominal level (102%). The modifier (CS-7SB) is 14% below its nominal concentration, while the TiDG and MaxCalix concentrations are at and above their nominal concentrations, respectively. This analysis confirms the solvent may require the addition of modifier. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended.

  17. Ambient krypton-85 air sampling at Hanford

    International Nuclear Information System (INIS)

    Trevathan, M.S.; Price, K.R.

    1985-01-01

    In the fall of 1982, the Environmental Evaluations Section of Pacific Northwest Laboratory (PNL) initiated a network of continuous 85 Kr air samplers located on and around the Hanford Site. This effort was in response to the resumption of operations at a nuclear fuel reprocessing plant located onsite where 85 Kr was to be released during fuel dissolution. Preoperational data were collected using noble gas samplers designed by the Environmental Protection Agency-Las Vegas (EPA-LV). The samplers functioned erratically resulting in excessive maintenance costs and prompted a search for a new sampling system. State-of-the-art 85 Dr sampling methods were reviewed and found to be too costly, too complex and inappropriate for field application, so a simple bag collection system was designed and field tested. The system is composed of a reinforced, heavy plastic bag, connected to a variable flow pump and housed in a weatherproof enclosure. At the end of the four week sampling period the air in the bag is transferred by a compressor into a pressure tank for easy transport to the laboratory for analysis. After several months of operation, the air sampling system has proven its reliability and sensitivity to ambient levels of 85 Kr

  18. Ambient krypton-85 air sampling at Hanford

    International Nuclear Information System (INIS)

    Trevathan, M.S.; Price, K.R.

    1984-10-01

    In the fall of 1982, the Environmental Evaluations Section of Pacific Northwest Laboratory (PNL) initiated a network of continuous krypton-85 air samplers located on and around the Hanford Site. This effort was in response to the resumption of operations at a nuclear fuel reprocessing plant located onsite where krypton-85 was to be released during fuel dissolution. Preoperational data were collected using noble gas samplers designed by the Environmental Protection Agency-Las Vegas (EPA-LV). The samplers functioned erratically resulting in excessive maintenance costs and prompted a search for a new sampling system. State of the art krypton-85 sampling methods were reviewed and found to be too costly, too complex and inappropriate for field application, so a simple bag collection system was designed and field tested. The system is composed of a reinforced, heavy plastic bag, connected to a variable flow pump and housed in a weatherproof enclosure. At the end of the four week sampling period the air in the bag is transferred by a compressor into a pressure tank for easy transport to the laboratory for analysis. After several months of operation, the air sampling system has proven its reliability and sensitivity to ambient levels of krypton-85. 3 references, 3 figures, 1 table

  19. Gamma radiation measurement in select sand samples from Camburi beach - Vitoria, Espirito Santo, Brazil: preliminary results

    International Nuclear Information System (INIS)

    Barros, Livia F.; Pecequilo, Brigitte R.S.; Aquino, Reginaldo R.

    2011-01-01

    The variation of natural radioactivity along the surface of the beach sands of Camburi, located in Vitoria, capital of Espirito Santo, southeastern Brazil, was determined from the contents of 226 Ra, 232 Th and 40 K. Eleven collecting points was selected along all the 6 km extension of the Camburi beach. Sand samples collected from all established points on January 2011 were dried and sealed in standard 100 mL polyethylene flasks and measured by high resolution gamma spectrometry after a 4 weeks ingrowth period, in order to allow the secular equilibrium in the 238 U and 232 Th series. The 226 Ra concentration was determined from the weighted average concentrations of 214 Pb and 214 Bi. The 232 Th concentration was determined from the weighted average concentrations of 228 Ac, 212 Pb and 212 Bi and the 40 K from its single gamma transition. Preliminary results show activity concentrations varying from 5 Bq.kg -1 to 222 Bq.kg -1 for 226 Ra and from 14 Bq.kg -1 to 1074 Bq.kg -' 1 for 232 Th, both with the highest values for Camburi South and Central. For 40 K, the activity concentrations ranged from 14 Bq.kg -1 to 179 Bq.kg -1 and the highest values were obtained for Camburi South. (author)

  20. Cast Stone Oxidation Front Evaluation: Preliminary Results For Samples Exposed To Moist Air

    International Nuclear Information System (INIS)

    Langton, C. A.; Almond, P. M.

    2013-01-01

    The rate of oxidation is important to the long-term performance of reducing salt waste forms because the solubility of some contaminants, e.g., technetium, is a function of oxidation state. TcO 4 - in the salt solution is reduced to Tc(IV) and has been shown to react with ingredients in the waste form to precipitate low solubility sulfide and/or oxide phases. Upon exposure to oxygen, the compounds containing Tc(IV) oxidize to the pertechnetate ion, Tc(VII)O 4 - , which is very soluble. Consequently the rate of technetium oxidation front advancement into a monolith and the technetium leaching profile as a function of depth from an exposed surface are important to waste form performance and ground water concentration predictions. An approach for measuring contaminant oxidation rate (effective contaminant specific oxidation rate) based on leaching of select contaminants of concern is described in this report. In addition, the relationship between reduction capacity and contaminant oxidation is addressed. Chromate (Cr(VI) was used as a non-radioactive surrogate for pertechnetate, Tc(VII), in Cast Stone samples prepared with 5 M Simulant. Cast Stone spiked with pertechnetate was also prepared and tested. Depth discrete subsamples spiked with Cr were cut from Cast Stone exposed to Savannah River Site (SRS) outdoor ambient temperature fluctuations and moist air. Depth discrete subsamples spiked with Tc-99 were cut from Cast Stone exposed to laboratory ambient temperature fluctuations and moist air. Similar conditions are expected to be encountered in the Cast Stone curing container. The leachability of Cr and Tc-99 and the reduction capacities, measured by the Angus-Glasser method, were determined for each subsample as a function of depth from the exposed surface. The results obtained to date were focused on continued method development and are preliminary and apply to the sample composition and curing / exposure conditions described in this report. The Cr oxidation front

  1. 40 CFR 61.34 - Air sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Air sampling. 61.34 Section 61.34... sampling. (a) Stationary sources subject to § 61.32(b) shall locate air sampling sites in accordance with a... concentrations calculated within 30 days after filters are collected. Records of concentrations at all sampling...

  2. Simon and Garner effects with color and location: Evidence for two independent routes by which irrelevant location influences performance.

    Science.gov (United States)

    Fitousi, Daniel

    2016-11-01

    Classic theories of attention assume that the processing of a target's featural dimension (e.g., color) is contingent on the processing of its spatial location. The present study challenges this maxim. Three experiments evaluated the dimensional independence of spatial location and color using a combined Simon (Simon & Rudell Journal of Applied Psychology: 51, 300-304, 1967) and Garner (Garner, 1974) design. The results showed that when the stimulus's spatial location was rendered more discriminable than its color (Experiment 1 and 2), both Simon and Garner effects were obtained, and location interfered with color judgments to a larger extent than color intruded on location. However, when baseline discriminabilities of location and color were matched (Experiment 3), no Garner interference was obtained from location to color, yet Simon effects still emerged, proving resilient to manipulations of discriminability. Further correlational and distributional analyses showed that Garner and Simon effects have dissociable effects. A triple-route model is proposed to account for the results, according to which irrelevant location can influence performance via two independent location routes/codes.

  3. Tank 101-SY Window E core sample: Interpretation of results

    International Nuclear Information System (INIS)

    Reynolds, D.A.

    1993-02-01

    A full depth core sample was taken for tank 241-SY-101 in December 1991 during a time period called ''Window E.'' This was the second full depth core sample from this tank during the year. The core had two major portions that are known as the convective zone and the nonconvective zone. A crust was on the top of tank but as poorly sampled. The analysis of the Window E core sample stressed segment composite chemical analysis instead of segment by segment as in Window C. Adiabatic calorimetry on samples from both cores showed a slow self heating reaction above 150 degrees C on dried samples. The exothermic events were milder than similar synthetic samples. The chemical and physical properties complemented the information from Window C. The Window E material from the convective zone was more viscous than the Window C convective zone material. The nonconvective zone viscosities were similar for both cores. Heating and dilution tests were made to test mitigation concepts

  4. Tank 101-SY Window E core sample: Interpretation of results

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, D.A.

    1993-02-01

    A full depth core sample was taken for tank 241-SY-101 in December 1991 during a time period called ``Window E.`` This was the second full depth core sample from this tank during the year. The core had two major portions that are known as the convective zone and the nonconvective zone. A crust was on the top of tank but as poorly sampled. The analysis of the Window E core sample stressed segment composite chemical analysis instead of segment by segment as in Window C. Adiabatic calorimetry on samples from both cores showed a slow self heating reaction above 150{degrees}C on dried samples. The exothermic events were milder than similar synthetic samples. The chemical and physical properties complemented the information from Window C. The Window E material from the convective zone was more viscous than the Window C convective zone material. The nonconvective zone viscosities were similar for both cores. Heating and dilution tests were made to test mitigation concepts.

  5. Sample results from the interim salt disposition program macrobatch 9 tank 21H qualification samples

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-11-01

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 9 for the Interim Salt Disposition Program (ISDP). This document reports characterization data on the samples of Tank 21H.

  6. Blood gas sample spiking with total parenteral nutrition, lipid emulsion, and concentrated dextrose solutions as a model for predicting sample contamination based on glucose result.

    Science.gov (United States)

    Jara-Aguirre, Jose C; Smeets, Steven W; Wockenfus, Amy M; Karon, Brad S

    2018-05-01

    Evaluate the effects of blood gas sample contamination with total parenteral nutrition (TPN)/lipid emulsion and dextrose 50% (D50) solutions on blood gas and electrolyte measurement; and determine whether glucose concentration can predict blood gas sample contamination with TPN/lipid emulsion or D50. Residual lithium heparin arterial blood gas samples were spiked with TPN/lipid emulsion (0 to 15%) and D50 solutions (0 to 2.5%). Blood gas (pH, pCO2, pO2), electrolytes (Na+, K+ ionized calcium) and hemoglobin were measured with a Radiometer ABL90. Glucose concentration was measured in separated plasma by Roche Cobas c501. Chart review of neonatal blood gas results with glucose >300 mg/dL (>16.65 mmol/L) over a seven month period was performed to determine whether repeat (within 4 h) blood gas results suggested pre-analytical errors in blood gas results. Results were used to determine whether a glucose threshold could predict contamination resulting in blood gas and electrolyte results with greater than laboratory-defined allowable error. Samples spiked with 5% or more TPN/lipid emulsion solution or 1% D50 showed glucose concentration >500 mg/dL (>27.75 mmol/L) and produced blood gas (pH, pO 2 , pCO 2 ) results with greater than laboratory-defined allowable error. TPN/lipid emulsion, but not D50, produced greater than allowable error in electrolyte (Na + ,K + ,Ca ++ ,Hb) results at these concentrations. Based on chart review of 144 neonatal blood gas results with glucose >250 mg/dL received over seven months, four of ten neonatal intensive care unit (NICU) patients with glucose results >500 mg/dL and repeat blood gas results within 4 h had results highly suggestive of pre-analytical error. Only 3 of 36 NICU patients with glucose results 300-500 mg/dL and repeat blood gas results within 4 h had clear pre-analytical errors in blood gas results. Glucose concentration can be used as an indicator of significant blood sample contamination with either TPN

  7. Results of Self-Absorption Study on the Versapor 3000 Filters for Radioactive Particulate Air Sampling

    International Nuclear Information System (INIS)

    Barnett, J.M.

    2008-01-01

    Since the mid-1980s the Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as a correction factor for the self absorption of activity of particulate radioactive air samples. More recently, an effort was made to evaluate the current particulate radioactive air sample filters (Versapor(reg s ign) 3000) used at PNNL for self absorption effects. There were two methods used in the study, (1) to compare the radioactivity concentration by direct gas-flow proportional counting of the filter to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection and (2) to evaluate sample filters by high resolution visual/infrared microscopy to determine the depth of material loading on or in the filter fiber material. Sixty samples were selected from the archive for acid digestion in the first method and about 30 samples were selected for high resolution visual/infrared microscopy. Mass loading effects were also considered. From the sample filter analysis, large error is associated with the average self absorption factor, however, when the data is compared directly one-to-one, statistically, there appears to be good correlation between the two analytical methods. The mass loading of filters evaluated was <0.2 mg cm-2 and was also compared against other published results. The microscopy analysis shows the sample material remains on the top of the filter paper and does not imbed into the filter media. Results of the microscopy evaluation lead to the conclusion that there is not a mechanism for significant self absorption. The overall conclusion is that self-absorption is not a significant factor in the analysis of filters used at PNNL for radioactive air stack sampling of radionuclide particulates and that an applied correction factor is conservative in determining overall sample activity. A new self absorption factor of 1.0 is recommended

  8. Location decision strategies for improving SMME business performance

    Directory of Open Access Journals (Sweden)

    Shereen Barnard

    2011-12-01

    Full Text Available Purpose: The primary objective of this study is to investigate the macro-environmental factors that may influence location decisions and how these choices may affect the business performance of SMMEs. Problem investigated: SMMEs in South Africa play an increasingly important role in stimulating economic activity, growth and employment creation. However, many SMMEs cease to exist within the first five years of operation due to various challenges faced by SMMEs on a daily basis. Many SMMEs owners disregard the importance of location, yet the geographical location can negatively influence the survival of the business. Several factors influence the choice of the location, which will ultimately have either a positive or negative effect on business performance. Methodology: A positivistic research methodology was adopted for this study. Seven hypotheses were constructed to achieve the primary objective of this study. The population for this study consisted of SMMEs in the Nelson Mandela Metropole from which a convenience sample of 175 SMMEs was selected. The measuring instrument, a self-developed questionnaire, consisted of three sections. The data collected included the demographical data of the respondents and their businesses, statements on location and various factors influencing location decisions as well as measurements of business performance. Cronbach Alpha coefficients were calculated to determine the reliability of the questionnaire items. Data analysis was done by calculating descriptive statistics, Pearson correlation coefficients and conducting a simple linear regression analysis. Cohen's d was used to determine the significance of between-factor differences. Findings and implications: The results of the study showed that positive relationships existed between all the independent variables (location, rental rates, employment, inflation, interest rates and green buildings and the dependent variable (business performance except for the

  9. Cleaning and Processing RSS measurements for Location Fingerprinting

    DEFF Research Database (Denmark)

    Kjærgaard, Mikkel Baun

    2007-01-01

    Handling variations in sampled Received Signal Strength (RSS) is neassary for achieving robust location fingerprinting (LF). Current research has only proposed limited system-specific models for how to handle the cleaning of RSS variations. However, this paper propose a novel model for both...

  10. A Simultaneous Study of Outsourcing and Location Choices

    DEFF Research Database (Denmark)

    Leiblein, Michael J.; Møller Larsen, Marcus; Pedersen, Torben

    This paper simultaneously evaluates factors affecting decisions regarding the organization and location of economic activity. The paper uses data from a comprehensive sample of exchanges involving public and private global semiconductor firms over the 1990 to 2005 time period. The paper accounts...

  11. A Simultaneous Examination of Outsourcing and Location Choices

    DEFF Research Database (Denmark)

    Leiblein, Michael J.; Larsen, Marcus M.; Pedersen, Torben

    2014-01-01

    This paper simultaneously evaluates factors affecting decisions regarding the organization and location of economic activity. The paper uses data from a comprehensive sample of exchanges involving public and private global semiconductor firms over the 1990 to 2005 time period. The paper accounts ...

  12. A Location Privacy Aware Friend Locator

    DEFF Research Database (Denmark)

    Siksnys, Laurynas; Thomsen, Jeppe Rishede; Saltenis, Simonas

    2009-01-01

    to trade their location privacy for quality of service, limiting the attractiveness of the services. The challenge is to develop a communication-efficient solution such that (i) it detects proximity between a user and the user’s friends, (ii) any other party is not allowed to infer the location of the user...

  13. Location capability of a sparse regional network (RSTN) using a multi-phase earthquake location algorithm (REGLOC)

    Energy Technology Data Exchange (ETDEWEB)

    Hutchings, L.

    1994-01-01

    The Regional Seismic Test Network (RSTN) was deployed by the US Department of Energy (DOE) to determine whether data recorded by a regional network could be used to detect and accurately locate seismic events that might be clandestine nuclear tests. The purpose of this paper is to evaluate the location capability of the RSTN. A major part of this project was the development of the location algorithm REGLOC and application of Basian a prior statistics for determining the accuracy of the location estimates. REGLOC utilizes all identifiable phases, including backazimuth, in the location. Ninty-four events, distributed throughout the network area, detected by both the RSTN and located by local networks were used in the study. The location capability of the RSTN was evaluated by estimating the location accuracy, error ellipse accuracy, and the percentage of events that could be located, as a function of magnitude. The location accuracy was verified by comparing the RSTN results for the 94 events with published locations based on data from the local networks. The error ellipse accuracy was evaluated by determining whether the error ellipse includes the actual location. The percentage of events located was assessed by combining detection capability with location capability to determine the percentage of events that could be located within the study area. Events were located with both an average crustal model for the entire region, and with regional velocity models along with station corrections obtained from master events. Most events with a magnitude <3.0 can only be located with arrivals from one station. Their average location errors are 453 and 414 km for the average- and regional-velocity model locations, respectively. Single station locations are very unreliable because they depend on accurate backazimuth estimates, and backazimuth proved to be a very unreliable computation.

  14. Data Validation Package December 2015 Groundwater Sampling at the Ambrosia Lake, New Mexico, Disposal Site March 2016

    Energy Technology Data Exchange (ETDEWEB)

    Tsosie, Bernadette [USDOE Office of Legacy Management, Washington, DC (United States); Johnson, Dick [Navarro Research and Engineering, Inc., Oak Ridge, TN (United States)

    2016-03-01

    The Long-Term Surveillance Plan for the Ambrosia Lake, New Mexico, Disposal Site does not require groundwater monitoring because groundwater in the uppermost aquifer is of limited use, and supplemental standards have been applied to the aquifer. However, at the request of the New Mexico Environment Department, the U.S. Department of Energy conducts annual monitoring at three locations: monitoring wells 0409, 0675, and 0678. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for US. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). Monitoring Well 0409 was not sampled during this event because it was dry. Water levels were measured at each sampled well. One duplicate sample was collected from location 0675. Groundwater samples from the two sampled wells were analyzed for the constituents listed in Table 1. Time-concentration graphs for selected analytes are included in this report. At well 0675, the duplicate results for total dissolved solids and for most metals (magnesium, molybdenum, potassium, selenium, sodium, and uranium) were outside acceptance criteria, which may indicate non-homogeneous conditions at this location. November 2014 results for molybdenum and uranium at well 0675 also were outside acceptance criteria. The well condition will be evaluated prior to the next sampling event.

  15. Fallout Concentration Various Environmental Samples in Indonesia

    International Nuclear Information System (INIS)

    Sutarman

    2001-01-01

    The testing of nuclear weapons have been carried out by the advanced countries, such as United States, Russian Federation, United Kingdom, France, China, India and Pakistan, since about 1945 until 1998. Nuclear weapons tests were conducted at various locations, on and above the earth's surface or underground or on and under the ocean's surface. Nuclear explosions caused the radionuclides of fission product, such as 131 l, 89 Sr, 90 Sr, 134 Cs, 137 Cs, and 239 Pu released to the atmospheric layer. In the atmospheric layer, the long-lived radionuclides, i.e, 90 Sr dan 137 Cs will be distributed into the environment as the fallout radionuclides, and deposited in the various environmental samples (soil, water, and biota). In general, at several locations in Indonesia the 90 Sr and 137 Cs in the various environmental samples still can be detected. The data of measurement results of 90 Sr and 137 Cs concentrations were generally lower than that from some countries in the northern hemisphere. (author)

  16. Smart location system; Sistema de localizacao inteligente Smart Location System

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Jose Augusto Pereira da; Antunes, Rodrigo de Castro; Azevedo, Fabio Augusto Ferreira de [PipeWay Engenharia, Rio de Janeiro, RJ (Brazil); Afonso, Orlando de Jesus Ribeiro [Instituto de Pesquisas da Marinha, Rio de Janeiro, RJ (Brazil); Matsuura, Minoru; Santa Cruz, Sergio de Freitas [TRANSPETRO - PETROBRAS Transportes, Rio de Janeiro, RJ (Brazil); Santos, Jose Alberto Costa dos; Hashiguchi, Decio Issao [GDK Engenharia (Brazil)

    2003-07-01

    This paper describes the technology used in the Intelligent Location System developed by Pipeway and includes some of the results already obtained optimizing repair time and logistic costs during the location of anomalies detected by intelligent pigs, a joint operation within the scope of the contract for Sub sea Pipeline Recovery in the Guanabara Bay with PETROBRAS/TRANSPETRO and GDK Engenharia. The system uses the ELF (Extra Low Frequency) transmission and reception technology at points near a pipe, with or without concrete coating, whose signals are recorded in the inspection tool memory to accurately establish reference points, thus preventing excessive dig work or dredging when human and operational risks tend to be high. (author)

  17. Sampling and analysis plan for the consolidated sludge samples from the canisters and floor of the 105-K East basin

    International Nuclear Information System (INIS)

    BAKER, R.B.

    1999-01-01

    This Sampling and Analysis Plan (SAP) provides direction for sampling of fuel canister and floor Sludge from the K East Basin to complete the inventory of samples needed for Sludge treatment process testing. Sample volumes and sources consider recent reviews made by the Sludge treatment subproject. The representative samples will be characterized to the extent needed for the material to be used effectively for testing. Sampling equipment used allows drawing of large volume sludge samples and consolidation of sample material from a number of basin locations into one container. Once filled, the containers will be placed in a cask and transported to Hanford laboratories for recovery and evaluation. Included in the present SAP are the logic for sample location selection, laboratory analysis procedures required, and reporting needed to meet the Data Quality Objectives (DQOs) for this initiative

  18. 40 CFR 89.507 - Sample selection.

    Science.gov (United States)

    2010-07-01

    ... Auditing § 89.507 Sample selection. (a) Engines comprising a test sample will be selected at the location...). However, once the manufacturer ships any test engine, it relinquishes the prerogative to conduct retests...

  19. An antithetic variate to facilitate upper-stem height measurements for critical height sampling with importance sampling

    Science.gov (United States)

    Thomas B. Lynch; Jeffrey H. Gove

    2013-01-01

    Critical height sampling (CHS) estimates cubic volume per unit area by multiplying the sum of critical heights measured on trees tallied in a horizontal point sample (HPS) by the HPS basal area factor. One of the barriers to practical application of CHS is the fact that trees near the field location of the point-sampling sample point have critical heights that occur...

  20. Instrumental neutron activation analysis of soil sample

    International Nuclear Information System (INIS)

    Abdul Khalik Haji Wood.

    1983-01-01

    This paper describes the analysis of soil samples collected from 5 different location around Sungai Lui, Kajang, Selangor, Malaysia. These sample were taken at 22-24 cm from the top of the ground and were analysed using the techniques of Instrumental Neutron Activation Analysis (INAA). The analysis on soil sample taken above 22-24 cm level were done in order to determine if there is any variation in elemental contents at different sampling levels. The results indicate a wide variation in the contents of the samples. About 30 elements have been analysed. The major ones are Na, I, Cl, Mg, Al, K, Ti, Ca and Fe. Trace elements analysed were Ba, Sc, V, Cr, Mn, Ga, As, Zn, Br, Rb, Co, Hf, Zr, Th, U, Sb, Cs, Ce, Sm, Eu, Tb, Dy, Yb, Lu and La. (author)

  1. Single point aerosol sampling: Evaluation of mixing and probe performance in a nuclear stack

    Energy Technology Data Exchange (ETDEWEB)

    Rodgers, J.C.; Fairchild, C.I.; Wood, G.O. [Los Alamos National Laboratory, NM (United States)] [and others

    1995-02-01

    Alternative Reference Methodologies (ARMs) have been developed for sampling of radionuclides from stacks and ducts that differ from the methods required by the U.S. EPA. The EPA methods are prescriptive in selection of sampling locations and in design of sampling probes whereas the alternative methods are performance driven. Tests were conducted in a stack at Los Alamos National Laboratory to demonstrate the efficacy of the ARMs. Coefficients of variation of the velocity tracer gas, and aerosol particle profiles were determined at three sampling locations. Results showed numerical criteria placed upon the coefficients of variation by the ARMs were met at sampling stations located 9 and 14 stack diameters from flow entrance, but not at a location that is 1.5 diameters downstream from the inlet. Experiments were conducted to characterize the transmission of 10 {mu}m aerodynamic equivalent diameter liquid aerosol particles through three types of sampling probes. The transmission ratio (ratio of aerosol concentration at the probe exit plane to the concentration in the free stream) was 107% for a 113 L/min (4-cfm) anisokinetic shrouded probe, but only 20% for an isokinetic probe that follows the EPA requirements. A specially designed isokinetic probe showed a transmission ratio of 63%. The shrouded probe performance would conform to the ARM criteria; however, the isokinetic probes would not.

  2. Solvent hold tank sample results for MCU-16-1363-1364-1365: November 2016 monthly sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-06-16

    Savannah River National Laboratory (SRNL) received one set of three Solvent Hold Tank (SHT) samples (MCU-16-1363-1364-1365), pulled on 11/15/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1363-1364-1365 indicated the Isopar™L concentration is at its nominal level (100%). The extractant (MaxCalix) and the modifier (CS- 7SB) are 8% and 2 % below their nominal concentrations. The suppressor (TiDG) is 7% below its nominal concentration. A summary of the concentration of the relevant solvent components is shown below.

  3. Solvent hold tank sample results for MCU-16-1317-1318-1319: September 2016 monthly sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-06-16

    Savannah River National Laboratory (SRNL) received one set of three Solvent Hold Tank (SHT) samples (MCU-16-1317-1318-1319), pulled on 09/12/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1317-1318-1319 indicated the Isopar™L concentration is above its nominal level (102%). The extractant (MaxCalix) and the modifier (CS-7SB) are 5% and 9% below their nominal concentrations. The suppressor (TiDG) is 76% below its nominal concentration. A summary of the concentration of the relevant solvent components is shown below.

  4. Solvent hold tank sample results for MCU-16-1247-1248-1249: August 2016 monthly sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-06-16

    Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-1247-1248-1249), pulled on 08/22/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1247-1248-1249 indicated the Isopar™L concentration is above its nominal level (101%). The extractant (MaxCalix) and the modifier (CS-7SB) are 7% and 9 % below their nominal concentrations. The suppressor (TiDG) is 63% below its nominal concentration. A summary of the concentration of the relevant solvent components is shown below.

  5. Location coding by opponent neural populations in the auditory cortex.

    Directory of Open Access Journals (Sweden)

    G Christopher Stecker

    2005-03-01

    Full Text Available Although the auditory cortex plays a necessary role in sound localization, physiological investigations in the cortex reveal inhomogeneous sampling of auditory space that is difficult to reconcile with localization behavior under the assumption of local spatial coding. Most neurons respond maximally to sounds located far to the left or right side, with few neurons tuned to the frontal midline. Paradoxically, psychophysical studies show optimal spatial acuity across the frontal midline. In this paper, we revisit the problem of inhomogeneous spatial sampling in three fields of cat auditory cortex. In each field, we confirm that neural responses tend to be greatest for lateral positions, but show the greatest modulation for near-midline source locations. Moreover, identification of source locations based on cortical responses shows sharp discrimination of left from right but relatively inaccurate discrimination of locations within each half of space. Motivated by these findings, we explore an opponent-process theory in which sound-source locations are represented by differences in the activity of two broadly tuned channels formed by contra- and ipsilaterally preferring neurons. Finally, we demonstrate a simple model, based on spike-count differences across cortical populations, that provides bias-free, level-invariant localization-and thus also a solution to the "binding problem" of associating spatial information with other nonspatial attributes of sounds.

  6. First Results of the VLBI Experiment on Radar Location of the Asteroid 2012 DA14

    Directory of Open Access Journals (Sweden)

    Nechaeva M.

    2013-12-01

    Full Text Available An international VLBI experiment on radio location of the asteroid 2012 DA14 was organized on 2013 February 15–16, during its flyby close to Earth. The purpose of observations was to investigate and specify orbital parameters of the asteroid, as well as to evaluate its rotation period and other characteristics. The irradiation of the asteroid was performed by the RT-70 transmitter at Evpatoria (Crimea, Ukraine, while the reflected signals were successfully accepted by the two 32 m radio telescopes at Medicina (Bologna, Italy and Irbene (Ventspils, Latvia. Processing and interpretation of the data were performed both in the Radiophysical Research Institute at Nizhny Novgorod and in the Ventspils International Radio Astronomy Center. The first results of this experiment are presented and discussed.

  7. What Makes Professional Development Effective? Results from a National Sample of Teachers.

    Science.gov (United States)

    Garet, Michael S.; Porter, Andrew C.; Desimone, Laura; Birman, Beatrice F.; Yoon, Kwang Suk

    2001-01-01

    Used a national probability sample of 1,027 mathematics and science teachers to provide a large-scale empirical comparison of effects of different characteristics of professional development on teachers' learning. Results identify three core features of professional development that have significant positive effects on teachers' self-reported…

  8. MCNP Modeling Results for Location of Buried TRU Waste Drums

    International Nuclear Information System (INIS)

    Steinman, D K; Schweitzer, J S

    2006-01-01

    In the 1960's, fifty-five gallon drums of TRU waste were buried in shallow pits on remote U.S. Government facilities such as the Idaho National Engineering Laboratory (now split into the Idaho National Laboratory and the Idaho Completion Project [ICP]). Subsequently, it was decided to remove the drums and the material that was in them from the burial pits and send the material to the Waste Isolation Pilot Plant in New Mexico. Several technologies have been tried to locate the drums non-intrusively with enough precision to minimize the chance for material to be spread into the environment. One of these technologies is the placement of steel probe holes in the pits into which wireline logging probes can be lowered to measure properties and concentrations of material surrounding the probe holes for evidence of TRU material. There is also a concern that large quantities of volatile organic compounds (VOC) are also present that would contaminate the environment during removal. In 2001, the Idaho National Engineering and Environmental Laboratory (INEEL) built two pulsed neutron wireline logging tools to measure TRU and VOC around the probe holes. The tools are the Prompt Fission Neutron (PFN) and the Pulsed Neutron Gamma (PNG), respectively. They were tested experimentally in surrogate test holes in 2003. The work reported here estimates the performance of the tools using Monte-Carlo modelling prior to field deployment. A MCNP model was constructed by INEEL personnel. It was modified by the authors to assess the ability of the tools to predict quantitatively the position and concentration of TRU and VOC materials disposed around the probe holes. The model was used to simulate the tools scanning the probe holes vertically in five centimetre increments. A drum was included in the model that could be placed near the probe hole and at other locations out to forty-five centimetres from the probe-hole in five centimetre increments. Scans were performed with no chlorine in the

  9. The independent effects of match location, match result and the quality of opposition on subjective wellbeing in under 23 soccer players: a case study.

    Science.gov (United States)

    Abbott, Will; Brownlee, Thomas E; Harper, Liam D; Naughton, Robert J; Clifford, Tom

    2018-03-04

    This study examined if subjective wellbeing in soccer players was affected by match location, match result and opposition quality before a match (PRE), 1 day after (POST-1), and 3 days after a match (POST-3). Eleven professional male soccer players from the under 23 squad playing in the Premier League 2 division completed a wellbeing questionnaire before and after 17 matches. Match training load (session-rating perceived exertion) was not different, regardless of the location, result, or quality of opposition faced (P > 0.05). Subjective wellbeing was not different at PRE (P > 0.05); however, at POST-1 and POST-3, stress and mood were ≥20% lower after playing away from home or losing (P sleep were ≥12% worse after playing against a higher-level opposition at POST-1. Coaches need to be aware that match location, match result and the quality of the opposition can influence post-match wellbeing, irrespective of match load.

  10. Analysis of the Touch-And-Go Surface Sampling Concept for Comet Sample Return Missions

    Science.gov (United States)

    Mandic, Milan; Acikmese, Behcet; Bayard, David S.; Blackmore, Lars

    2012-01-01

    This paper studies the Touch-and-Go (TAG) concept for enabling a spacecraft to take a sample from the surface of a small primitive body, such as an asteroid or comet. The idea behind the TAG concept is to let the spacecraft descend to the surface, make contact with the surface for several seconds, and then ascend to a safe location. Sampling would be accomplished by an end-effector that is active during the few seconds of surface contact. The TAG event is one of the most critical events in a primitive body sample-return mission. The purpose of this study is to evaluate the dynamic behavior of a representative spacecraft during the TAG event, i.e., immediately prior, during, and after surface contact of the sampler. The study evaluates the sample-collection performance of the proposed sampling end-effector, in this case a brushwheel sampler, while acquiring material from the surface during the contact. A main result of the study is a guidance and control (G&C) validation of the overall TAG concept, in addition to specific contributions to demonstrating the effectiveness of using nonlinear clutch mechanisms in the sampling arm joints, and increasing the length of the sampling arms to improve robustness.

  11. Elemental analysis and radiation hazards parameters of bauxite located in Saudi Arabia

    Science.gov (United States)

    Alashrah, S.; E Taher, A.

    2017-04-01

    Since Bauxite has been widely used in industry and in scientific investigations for producing Aluminum, it is important to measure the radionuclides concentrations to determine the health effect. The Bauxite mine is located in Az Zabirah city in Saudi Arabia. The concentrations of the radionuclides in the bauxite samples were measured using γ-ray spectrometer NaI (Tl). The average and range values of the concentrations of 226Ra, 232Th and 40K were 102.2 (141.1-62.7), 156.3 (202.8-102.8) and 116.8 (191.7- 48.9) Bq/kg respectively. These results were compared with the reported ranges in the literature from other locations around the world. The radiation hazard parameters; radium equivalent activity, annual dose, external hazard were also calculated and compared with the recommended levels by International Commission on Radiological Protection (ICRP-60) and united nations scientific committee on the effects of atomic radiation UNSCEAR reports. There are no studies for the natural radioactivity in the bauxite mine in Az Zabirah city, so these results are a start to establishing a database in this location.

  12. Tank 241-SY-102, January 2000 Compatibility Grab Samples Analytical Results for the Final Report

    International Nuclear Information System (INIS)

    BELL, K.E.

    2000-01-01

    This document is the format IV, final report for the tank 241-SY-102 (SY-102) grab samples taken in January 2000 to address waste compatibility concerns. Chemical, radiochemical, and physical analyses on the tank SY-102 samples were performed as directed in Comparability Grab Sampling and Analysis Plan for Fiscal Year 2000 (Sasaki 1999). No notification limits were exceeded. Preliminary data on samples 2SY-99-5, -6, and -7 were reported in ''Format II Report on Tank 241-SY-102 Waste Compatibility Grab Samples Taken in January 2000'' (Lockrem 2000). The data presented here represent the final results

  13. Sampling and Analysis Plan for the 221-U Facility

    International Nuclear Information System (INIS)

    Rugg, J.E.

    1998-02-01

    This sampling and analysis plan (SAP) presents the rationale and strategy for the sampling and analysis activities proposed to be conducted to support the evaluation of alternatives for the final disposition of the 221-U Facility. This SAP will describe general sample locations and the minimum number of samples required. It will also identify the specific contaminants of potential concern (COPCs) and the required analysis. This SAP does not define the exact sample locations and equipment to be used in the field due to the nature of unknowns associated with the 221-U Facility

  14. Interval estimation methods of the mean in small sample situation and the results' comparison

    International Nuclear Information System (INIS)

    Wu Changli; Guo Chunying; Jiang Meng; Lin Yuangen

    2009-01-01

    The methods of the sample mean's interval estimation, namely the classical method, the Bootstrap method, the Bayesian Bootstrap method, the Jackknife method and the spread method of the Empirical Characteristic distribution function are described. Numerical calculation on the samples' mean intervals is carried out where the numbers of the samples are 4, 5, 6 respectively. The results indicate the Bootstrap method and the Bayesian Bootstrap method are much more appropriate than others in small sample situation. (authors)

  15. Evaluation of Pu sample oscillations in CESAR

    Energy Technology Data Exchange (ETDEWEB)

    Brunet, M.

    1974-10-15

    A set of 12 plutonium samples of various compositions were oscillated in CESAR in 1973. Comparisons were made to the oscillated reactivity effect of a known specimen of U-235 and boron where the detector signals were corrected against a background signal based on comparison to the motion of a control rod in the central location of critical assembly. An equivalent sample method was tested first for various samples of U-235 and boron to establish a means of correction in the detector response. Inferred plutonium reaction rates in the experiments were compared to transport theory calculations using the APOLLO code. Addition effort is needed to reconcile differences in measured and calculated results requiring both chemical analyses of the plutonium isotopes in the samples and improved cross sections for the plutonium isotopes.

  16. A "shotgun" method for tracing the birth locations of sheep from flock tags, applied to scrapie surveillance in Great Britain.

    Science.gov (United States)

    Birch, Colin P D; Del Rio Vilas, Victor J; Chikukwa, Ambrose C

    2010-09-01

    Movement records are often used to identify animal sample provenance by retracing the movements of individuals. Here we present an alternative method, which uses the same identity tags and movement records as are used to retrace movements, but ignores individual movement paths. The first step uses a simple query to identify the most likely birth holding for every identity tag included in a database recording departures from agricultural holdings. The second step rejects a proportion of the birth holding locations to leave a list of birth holding locations that are relatively reliable. The method was used to trace the birth locations of sheep sampled for scrapie in abattoirs, or on farm as fallen stock. Over 82% of the sheep sampled in the fallen stock survey died at the holding of birth. This lack of movement may be an important constraint on scrapie transmission. These static sheep provided relatively reliable birth locations, which were used to define criteria for selecting reliable traces. The criteria rejected 16.8% of fallen stock traces and 11.9% of abattoir survey traces. Two tests provided estimates that selection reduced error in fallen stock traces from 11.3% to 3.2%, and in abattoir survey traces from 8.1% to 1.8%. This method generated 14,591 accepted traces of fallen stock from samples taken during 2002-2005 and 83,136 accepted traces from abattoir samples. The absence or ambiguity of flock tag records at the time of slaughter prevented the tracing of 16-24% of abattoir samples during 2002-2004, although flock tag records improved in 2005. The use of internal scoring to generate and evaluate results from the database query, and the confirmation of results by comparison with other database fields, are analogous to methods used in web search engines. Such methods may have wide application in tracing samples and in adding value to biological datasets. Crown Copyright 2010. Published by Elsevier B.V. All rights reserved.

  17. Heat Retreat Locations in Cities - The Survey-Based Location Analysis of Heat Relief

    Science.gov (United States)

    Neht, Alice; Maximini, Claudia; Prenger-Berninghoff, Kathrin

    2017-12-01

    The adaptation of cities to climate change effects is one of the major strategies in urban planning to encounter the challenges of climate change (IPCC 2014). One of the fields of climate change adaption is dealing with heat events that occur more frequently and with greater intensity. Cities in particular are vulnerable to these events due to high population and infrastructure density. Proceeding urbanization calls for the existence of sufficient heat retreat locations (HRL) to enable relief for the population from heat in summer. This is why an extensive analysis of HRL is needed. This paper aims at the development of a survey-based location analysis of heat relief by identifying user groups, locations and characteristics of HRL based on a home survey that was conducted in three German cities. Key results of the study show that the majority of the participants of the survey are users of existing HRL, are affected by heat, and perceive heat as a burden in summer. Moreover, HRL that are located in close proximity are preferred by most users while their effect depends on the regional context that has to be considered in the analysis. Hence, this research presents an approach to heat relief that underlines the importance of HRL in cities by referring to selected examples of HRL types in densely populated areas of cities. HRL should especially be established and secured in densely built-up areas of cities. According to results of the survey, most HRL are located in public spaces, and the overall accessibility of HRL turned out to be an issue.

  18. Evidence of previous but not current transmission of chikungunya virus in southern and central Vietnam: Results from a systematic review and a seroprevalence study in four locations.

    Directory of Open Access Journals (Sweden)

    Tran Minh Quan

    2018-02-01

    Full Text Available Arbovirus infections are a serious concern in tropical countries due to their high levels of transmission and morbidity. With the outbreaks of chikungunya (CHIKV in surrounding regions in recent years and the fact that the environment in Vietnam is suitable for the vectors of CHIKV, the possibility of transmission of CHIKV in Vietnam is of great interest. However, information about CHIKV activity in Vietnam remains limited.In order to address this question, we performed a systematic review of CHIKV in Vietnam and a CHIKV seroprevalence survey. The seroprevalence survey tested for CHIKV IgG in population serum samples from individuals of all ages in 2015 from four locations in Vietnam.The four locations were An Giang province (n = 137, Ho Chi Minh City (n = 136, Dak Lak province (n = 137, and Hue City (n = 136. The findings give us evidence of some CHIKV activity: 73/546 of overall samples were seropositive (13.4%. The age-adjusted seroprevalences were 12.30% (6.58-18.02, 13.42% (7.16-19.68, 7.97% (3.56-12.38, and 3.72% (1.75-5.69 in An Giang province, Ho Chi Minh City, Dak Lak province, and Hue City respectively. However, the age-stratified seroprevalence suggests that the last transmission ended around 30 years ago, consistent with results from the systematic review. We see no evidence for on-going transmission in three of the locations, though with some evidence of recent exposure in Dak Lak, most likely due to transmission in neighbouring countries. Before the 1980s, when transmission was occurring, we estimate on average 2-4% of the population were infected each year in HCMC and An Giang and Hue (though transmision ended earlier in Hue. We estimate lower transmission in Dak Lak, with around 1% of the population infected each year.In conclusion, we find evidence of past CHIKV transmission in central and southern Vietnam, but no evidence of recent sustained transmission. When transmission of CHIKV did occur, it appeared to be widespread and

  19. Using cell phone location to assess misclassification errors in air pollution exposure estimation.

    Science.gov (United States)

    Yu, Haofei; Russell, Armistead; Mulholland, James; Huang, Zhijiong

    2018-02-01

    Air pollution epidemiologic and health impact studies often rely on home addresses to estimate individual subject's pollution exposure. In this study, we used detailed cell phone location data, the call detail record (CDR), to account for the impact of spatiotemporal subject mobility on estimates of ambient air pollutant exposure. This approach was applied on a sample with 9886 unique simcard IDs in Shenzhen, China, on one mid-week day in October 2013. Hourly ambient concentrations of six chosen pollutants were simulated by the Community Multi-scale Air Quality model fused with observational data, and matched with detailed location data for these IDs. The results were compared with exposure estimates using home addresses to assess potential exposure misclassification errors. We found the misclassifications errors are likely to be substantial when home location alone is applied. The CDR based approach indicates that the home based approach tends to over-estimate exposures for subjects with higher exposure levels and under-estimate exposures for those with lower exposure levels. Our results show that the cell phone location based approach can be used to assess exposure misclassification error and has the potential for improving exposure estimates in air pollution epidemiology studies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Immigrants' location preferences

    DEFF Research Database (Denmark)

    Damm, Anna Piil

    This paper exploits a spatial dispersal policy for refugee immigrants to estimate the importance of local and regional factors for refugees' location preferences. The main results of a mixed proportional hazard competing risks model are that placed refugees react to high regional unemployment...

  1. Locative media

    CERN Document Server

    Wilken, Rowan

    2014-01-01

    Not only is locative media one of the fastest growing areas in digital technology, but questions of location and location-awareness are increasingly central to our contemporary engagements with online and mobile media, and indeed media and culture generally. This volume is a comprehensive account of the various location-based technologies, services, applications, and cultures, as media, with an aim to identify, inventory, explore, and critique their cultural, economic, political, social, and policy dimensions internationally. In particular, the collection is organized around the perception that the growth of locative media gives rise to a number of crucial questions concerning the areas of culture, economy, and policy.

  2. Status report on the Zagreb Radiocarbon Laboratory - AMS and LSC results of VIRI intercomparison samples

    Science.gov (United States)

    Sironić, Andreja; Krajcar Bronić, Ines; Horvatinčić, Nada; Barešić, Jadranka; Obelić, Bogomil; Felja, Igor

    2013-01-01

    A new line for preparation of the graphite samples for 14C dating by Accelerator Mass Spectrometry (AMS) in the Zagreb Radiocarbon Laboratory has been validated by preparing graphite from various materials distributed within the Fifth International Radiocarbon Intercomparison (VIRI) study. 14C activity of prepared graphite was measured at the SUERC AMS facility. The results are statistically evaluated by means of the z-score and u-score values. The mean z-score value of 28 prepared VIRI samples is (0.06 ± 0.23) showing excellent agreement with the consensus VIRI values. Only one sample resulted in the u-score value above the limit of acceptability (defined for the confidence interval of 99%) and this was probably caused by a random contamination of the graphitization rig. After the rig had been moved to the new adapted and isolated room, all u-score values laid within the acceptable limits. Our LSC results of VIRI intercomparison samples are also presented and they are all accepted according to the u-score values.

  3. Status report on the Zagreb Radiocarbon Laboratory - AMS and LSC results of VIRI intercomparison samples

    Energy Technology Data Exchange (ETDEWEB)

    Sironic, Andreja [Department of Experimental Physics, Ruder Boskovic Institute, Bijenicka 54, 10000 Zagreb (Croatia); Krajcar Bronic, Ines, E-mail: krajcar@irb.hr [Department of Experimental Physics, Ruder Boskovic Institute, Bijenicka 54, 10000 Zagreb (Croatia); Horvatincic, Nada; Baresic, Jadranka; Obelic, Bogomil; Felja, Igor [Department of Experimental Physics, Ruder Boskovic Institute, Bijenicka 54, 10000 Zagreb (Croatia)

    2013-01-15

    A new line for preparation of the graphite samples for {sup 14}C dating by Accelerator Mass Spectrometry (AMS) in the Zagreb Radiocarbon Laboratory has been validated by preparing graphite from various materials distributed within the Fifth International Radiocarbon Intercomparison (VIRI) study. {sup 14}C activity of prepared graphite was measured at the SUERC AMS facility. The results are statistically evaluated by means of the z-score and u-score values. The mean z-score value of 28 prepared VIRI samples is (0.06 {+-} 0.23) showing excellent agreement with the consensus VIRI values. Only one sample resulted in the u-score value above the limit of acceptability (defined for the confidence interval of 99%) and this was probably caused by a random contamination of the graphitization rig. After the rig had been moved to the new adapted and isolated room, all u-score values laid within the acceptable limits. Our LSC results of VIRI intercomparison samples are also presented and they are all accepted according to the u-score values.

  4. Elemental contents in soil samples in Wad Hamid, River Nile State

    International Nuclear Information System (INIS)

    Mohammed, Khansaa Elawad Elhag

    2016-03-01

    In the present study a total of 30 samples were collected from Wad Hamid River Nile State. Sampling area of (two feddan) of agricultural soil. The sampling area was divided in two locations (fertile and non fertile soil). The samples were analyzed for their content of 13 elements (K, Ca, Ti, Mn, Fe, Cu, Zn, Pb, Rb, Sr, Y, Zr, and Np). 10 samples from location 1 (non-fertile soil) and 20 samples from location 2 (fertile soil). X-ray fluorescence (X RF) Spectrometer (system used based on 1"0"9"Cd excitation 1"0"9"Cd source which has an average energy of 22.6 kev and able to excite the elements from Z = 13 to 92 using K and L lines) used to identify the elemental concentration in soil samples. The reliability of X RF technique as multi elements detecting method for measuring elements concentration in soil sample , (IAEA-SOIL-7) standard reference material was used. Measured values found in agreement with the certified values. The average elemental concentration of K,Ca, Ti, Fe, Cu, Zn, Pb, Sr, Y, Zr, and Np in location 1 were 878, 29690, 13400, 983, 70380, 10.07, 19.07, 40.92,261.4, 23.59,294.8, 47.82, while the average elemental concentration in location 2 were 9848, 27780, 13076,13076,989, 68135, 9.6, 96.3 19.86, 43.7, 225.5, 22.49, 284.75, 46.15, respectively. comparison between the average elemental concentration in fertile soil and non-fertile was done correlations between element were performed Cluster analyses of element in soil samples were obtained comparison between this study and data from literature were done. The elemental concentration in location 1 (non- fertile soil) are higher than location 2 ( fertile soil) because the plant absorbed fertilizer of soil and transfer most elements in soil to plant. (Author)

  5. Determine the prevalence of Brucella spp. and Leptospira spp. in blood samples by multiplex polymerase chain reaction collected from cattle, sheep and goats in herds located in provinces of Iran

    Directory of Open Access Journals (Sweden)

    Faham Khamesipour

    2014-05-01

    Full Text Available Leptospirosis and brucellosis are common zoonosis that affect many species of mammals mostly causing economical losses. Further, very important fact is huge danger for human and animal health around the world. The purpose of the study is to determine the prevalence of Brucella spp. and Leptospira spp. using multiplex polymerase chain reaction (mPCR method, in blood samples collected from cattle, sheep and goats. In this study, a total number of 250 blood samples (5 cc of blood with ethilen diamin tetra asetic acid were collected randomly from 100 cattle, 80 sheep and 70 goats located on 6 herds in Chaharmahal Va Bakhtiari and Esfahan provinces, Iran. After DNA extraction and setting of mPCR for Brucella spp. and Leptospira spp. mPCR products were screened. The DNA of these microorganisms was detected by multiplex PCR from 31 and 21 out of 100 cattle, respectively. Four of 70 goat’s blood samples from goat breeding farms were positive for Leptospira spp. and 11 were positive for Brucella spp. Out of 80 sheep blood samples 23 were positive for Brucella spp. and 14 for Leptospira spp. The results of the present study show ruminant as an important reservoir for transmission of these zoonotic diseases to humans in Iran. mPCR has the ability to concurrently detect both Brucella and Leptospira species from blood samples of ruminants. The convenience and the possibility of detection of both bacteria at a time, strongly support the use of this mPCR for routine diagnostics.

  6. 40 CFR 90.507 - Sample selection.

    Science.gov (United States)

    2010-07-01

    ... Auditing § 90.507 Sample selection. (a) Engines comprising a test sample will be selected at the location... manufacturer ships any test engine, it relinquishes the prerogative to conduct retests as provided in § 90.508...

  7. Obtaining location/arrival-time and location/outflow-quantity distributions for steady flow systems

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    A steady, two-dimensional flow system is used to demonstrate the application of location/arrival-time and location/outflow-quantity curves in determining the environmental consequences of groundwater contamination. The subsurface geologic and hydrologic evaluations needed to obtain the arrival results involve a sequence of four phases: system identification, new potential determination, flow systems kinematics, and contaminant transport analysis. Once these phases are completed, they are effectively summarized and easily used to evaluate environmental consequences through the arrival distributions

  8. PIXE analysis applied to characterized water samples

    International Nuclear Information System (INIS)

    Santos, Maristela S.; Carneiro, Luana Gomes; Medeiros, Geiza; Sampaio, Camilla; Martorell, Ana Beatriz Targino; Gouvea, Stella; Cunha, Kenya Moore Dias da

    2011-01-01

    Araxa, in Brazil, is a naturally high background area located in the State of Minas Gerais with a population of about 93 672 people. Araxa is historical city famous for its mineral water sources and mud from Termas de Araxa spa, which have been used for therapeutic, and recreation purposes. Other important aspect of economy of the city are mining and metallurgic industries. In the Araxa area is located the largest deposit of pyrochlore, a niobium mineral, and also a deposit of apatite, a phosphate mineral both containing Th and U associated to crystal lattice. The minerals are obtained from open pit mines, the minerals are processed in industrial also located in city of Araxa, these plants process the pyrochlore and apatite to obtain the Fe-Nb alloy and the concentrate of phosphate, respectively. Studies were developed in this area to assessment the occupational risk of the workers due to exposure to dust particles during the routine working, however very few studies evaluated the water contamination outside the mines in order to determine the metal (stables elements) concentrations in water and also the concentrations of the radionuclides in water. This paper presents the previous results of a study to identify and determine the concentrations of metals (stables elements) and radionuclides in river around the city. The water from these rivers is used as drinking water and irrigation water. The water samples were collected in different rivers around the Araxa city and the samples were analyzed using PIXE technique. A proton beam of 2 MeV obtained from the van de Graaff electrostatic accelerator was used to induce the characteristic X-rays. S, K, Ca, Cr, Mn, Fe, Ni, Zn, Ba, Pb and U were identified in the mass spectrum of the samples. The elemental mass concentrations were compared using a non-parametric statistical test. The results of the statistical test showed that the elemental mass concentrations did not present the same distribution. These results indicated

  9. Air sampling in the workplace

    International Nuclear Information System (INIS)

    Hickey, E.E.; Stoetzel, G.A.; Strom, D.J.; Cicotte, G.R.; Wiblin, C.M.; McGuire, S.A.

    1993-09-01

    This report provides technical information on air sampling that will be useful for facilities following the recommendations in the NRC's Regulatory Guide 8.25, Revision 1, ''Air sampling in the Workplace.'' That guide addresses air sampling to meet the requirements in NRC's regulations on radiation protection, 10 CFR Part 20. This report describes how to determine the need for air sampling based on the amount of material in process modified by the type of material, release potential, and confinement of the material. The purposes of air sampling and how the purposes affect the types of air sampling provided are discussed. The report discusses how to locate air samplers to accurately determine the concentrations of airborne radioactive materials that workers will be exposed to. The need for and the methods of performing airflow pattern studies to improve the accuracy of air sampling results are included. The report presents and gives examples of several techniques that can be used to evaluate whether the airborne concentrations of material are representative of the air inhaled by workers. Methods to adjust derived air concentrations for particle size are described. Methods to calibrate for volume of air sampled and estimate the uncertainty in the volume of air sampled are described. Statistical tests for determining minimum detectable concentrations are presented. How to perform an annual evaluation of the adequacy of the air sampling is also discussed

  10. Determination of samples with TSP size at PLTU Pacitan, Jawa Timur have been done

    International Nuclear Information System (INIS)

    Rusmanto, Tri; Mulyono; Irianto, Bambang

    2013-01-01

    Sampling is done using equipment High Volume Air Sampler (HVAS) and analysis using gamma spectrometer. Sampling at 3 locations, each location of the sampling carried out 24 hours, air samples on filter conditioned at room temperature, weighed to a contained weight, counting for 24 hours with gamma spectrometer. The result of qualitative and quantitative analysis of filter TSP was contained of locations I Ra-226 = 0,000888 Bq/m 3 , Pb-212 = 0,000356 Bq/m 3 , Pb-214 = 0,000859 Bq/m 3 , Bi-214 = 0,000712 Bq/m 3 , Ac-228 = 0,004447 Bq/m 3 , K-40 = 0,035454 Bq/m 3 ) , Locations II Ra-226 = 0,00113 Bq/m 3 , Pb-212 = 0,00079 Bq/m 3 , Pb-214 = 0,001351 Bq/m 3 , Bi-214 = 0,000433 Bq/m 3 , Ac-228 = 0,007138 Bq/m 3 , K-40 = 0,018532 Bq/m 3 , Locations III Ra-226 = 0,001424 Bq/m 3 , Pb-212 = 0,000208 Bq/m 3 , Pb-214 = 000052 Bq/m 3 , Bi-214 = 0,001408 Bq/m 3 , Ac-228 = 0,008362 Bq/m 3 , K-40 = 0,020536 Bq/m 3 . Radionuclides activity was all still below quality of air enabled by BAPETEN. Become the activities of ambient air of PLTU area still be peaceful enough as settlement area. (author)

  11. The association between cognitive function and white matter lesion location in older adults: a systematic review

    Directory of Open Access Journals (Sweden)

    Bolandzadeh Niousha

    2012-10-01

    Full Text Available Abstract Background Maintaining cognitive function is essential for healthy aging and to function autonomously within society. White matter lesions (WMLs are associated with reduced cognitive function in older adults. However, whether their anatomical location moderates these associations is not well-established. This review systematically evaluates peer-reviewed evidence on the role of anatomical location in the association between WMLs and cognitive function. Methods In accordance with the preferred reporting items for systematic reviews and meta-analysis (PRISMA statement, databases of EMBASE, PUBMED, MEDLINE, and CINAHL, and reference lists of selected papers were searched. We limited our search results to adults aged 60 years and older, and studies published in the English language from 2000 to 2011. Studies that investigated the association between cognitive function and WML location were included. Two independent reviewers extracted: 1 study characteristics including sample size, sample characteristic, and study design; 2 WML outcomes including WML location, WML quantification method (scoring or volume measurement, strength of the MRI magnet in Tesla, and MRI sequence used for WML detection; and 3 cognitive function outcomes including cognitive tests for two cognitive domains of memory and executive function/processing speed. Results Of the 14 studies included, seven compared the association of subcortical versus periventricular WMLs with cognitive function. Seven other studies investigated the association between WMLs in specific brain regions (e.g., frontal, parietal lobes and cognitive function. Overall, the results show that a greater number of studies have found an association between periventricular WMLs and executive function/processing speed, than subcortical WMLs. However, whether WMLs in different brain regions have a differential effect on cognitive function remains unclear. Conclusions Evidence suggests that periventricular

  12. Comparison of leach results from field and laboratory prepared samples

    International Nuclear Information System (INIS)

    Oblath, S.B.; Langton, C.A.

    1985-01-01

    The leach behavior of saltstone prepared in the laboratory agrees well with that from samples mixed in the field using the Littleford mixer. Leach rates of nitrates and cesium from the current reference formulation saltstone were compared. The laboratory samples were prepared using simulated salt solution; those in the field used Tank 50 decontaminated supernate. For both nitrate and cesium, the field and laboratory samples showed nearly identical leach rates for the first 30 to 50 days. For the remaining period of the test, the field samples showed higher leach rates with the maximum difference being less than a factor of three. Ruthenium and antimony were present in the Tank 50 supernate in known amounts. Antimony-125 was observed in the leachate and a fractional leach rate was calculated to be at least a factor of ten less than that of 137 Cs. No 106 Ru was observed in the leachate, and the release rate was not calculated. However, based on the detection limits for the analysis, the ruthenium leach rate must also be at least a factor of ten less than cesium. These data are the first measurements of the leach rates of Ru and Sb from saltstone. The nitrate leach rates for these samples were 5 x 10 -5 grams of nitrate per square cm per day after 100 days for the laboratory samples and after 200 days for the field samples. These values are consistent with the previously measured leach rates for reference formulation saltstone. The relative standard deviation in the leach rate is about 15% for the field samples, which all were produced from one batch of saltstone, and about 35% for the laboratory samples, which came from different batches. These are the first recorded estimates of the error in leach rates for saltstone

  13. Administration of antibiotic agents before intraoperative sampling in orthopedic infections alters culture results.

    Science.gov (United States)

    Al-Mayahi, Mohamed; Cian, Anais; Lipsky, Benjamin A; Suvà, Domizio; Müller, Camillo; Landelle, Caroline; Miozzari, Hermès H; Uçkay, Ilker

    2015-11-01

    Many physicians and surgeons think that prescribing antibiotics before intraoperative sampling does not alter the microbiological results. Case-control study of adult patients hospitalized with orthopedic infections. Among 2740 episodes of orthopedic infections, 1167 (43%) had received antibiotic therapy before surgical sampling. Among these, 220 (19%) grew no pathogens while the proportion of culture-negative results in the 2573 who had no preoperative antibiotic therapy was only 6%. By multivariate analyses, pre-operative antibiotic exposure was associated with significantly more culture-negative results (odds ratio 2.8, 95% confidence interval 2.1-3.7), more non-fermenting rods and skin commensals (odds ratio 2.8 and 3.0, respectively). Even a single pre-operative dose of antibiotic was significantly associated with subsequent culture-negative results (19/93 vs. 297/2350; χ²-test, p = 0.01) and skin commensals (17/74 vs. 274/2350; p = 0.01) compared to episodes without preceding prophylaxis. Prior antibiotic use, including single-dose prophylactic administrations, is three-fold associated with culture-negative results, non-fermenting rods and resistant skin commensals. Copyright © 2015 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  14. Data Validation Package November 2015 Groundwater and Surface Water Sampling at the Old and New Rifle, Colorado, Processing Sites February 2016

    Energy Technology Data Exchange (ETDEWEB)

    Bush, Richard [USDOE Office of Legacy Management, Washington, DC (United States); Lemke, Peter [Navarro Research and Engineering, Inc., Oak Ridge, TN (United States)

    2016-02-01

    and November 2014 sampling events. (Well RFN-0609 was inadvertently sampled instead of RFN-0195 in 2014.) The results for RFN-0195 have been corrected, and are included in associated time-concentration graphs for this location. Recent results for RFN-0195 are consistent with established trends with the possible exception of vanadium. The most recent result for vanadium showed an increase over recent values. Vanadium concentrations at RFN-0195 and other locations will continue to be evaluated in the future to determine the potential for deviations from established trends. The surface water locations were sampled to monitor the impact of groundwater discharge. COC concentrations at Colorado River surface water locations RFN-0324 and RFN-0326, downgradient of the site, remained low and were consistent with historical results, as shown in the time-concentration graphs. COC concentrations did not indicate there are any impacts related to groundwater discharge to the river. In many cases, elevated COC concentrations at the New Rifle site pond locations were observed, as shown in the time-versus concentration graphs. As noted in the GCAP, this indicates impacts from groundwater discharge to the ponds. Old Rifle Site Samples were collected at the Old Rifle site from eight monitoring wells and five surface locations in compliance with the December 2001 Groundwater Compliance Action Plan for the Old Rifle, Colorado, UMTRA Project Site (GJ0-2000-177-TAR). Analytes measured at the Old Rifle site included COCs (selenium, uranium, and vanadium), major cations, and major anions. Field measurements of total alkalinity, oxidation-reduction potential, pH, specific conductance, turbidity, temperature, were made at each location, and the water level was measured at each sampled well. The monitoring strategy described in the GCAP is designed to determine progress of the natural flushing process in meeting compliance standards for site COCs. Standards for selenium and vanadium are the

  15. Investigation on location-dependent detectability of a small mass for digital breast tomosynthesis evaluation

    Science.gov (United States)

    Lee, Changwoo; Baek, Jongduk; Park, Subok

    2016-03-01

    Digital breast tomosynthesis (DBT) is an emerging imaging modality for improved breast cancer detection and diagnosis [1-5]. Numerous efforts have been made to find quantitative metrics associated with mammographic image quality assessment, such as the exponent β of anatomical noise power spectrum, glandularity, contrast noise ratio, etc. [6-8]. In addition, with the use of Fourier-domain detectability for a task-based assessment of DBT, a stationarity assumption on reconstructed image statistics was often made [9-11], resulting in the use of multiple regions-of-interest (ROIs) from different locations in order to increase sample size. While all these metrics provide some information on mammographic image characteristics and signal detection, the relationship between these metrics and detectability in DBT evaluation has not been fully understood. In this work, we investigated spatial-domain detectability trends and levels as a function of the number of slices Ns at three different ROI locations on the same image slice, where background statistics differ in terms of the aforementioned metrics. Detectabilities for the three ROI locations were calculated using multi-slice channelized Hotelling observers with 2D/3D Laguerre-Gauss channels. Our simulation results show that detectability levels and trends as a function of Ns vary across these three ROI locations. They also show that the exponent β, mean glandularity, and mean attenuation coefficient vary across the three ROI locations but they do not necessarily predict the ranking of detectability levels and trends across these ROI locations.

  16. First Total Reflection X-Ray Fluorescence round-robin test of water samples: Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Borgese, Laura; Bilo, Fabjola [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy); Tsuji, Kouichi [Graduate School of Engineering, Osaka City University, Osaka (Japan); Fernández-Ruiz, Ramón [Servicio Interdepartamental de Investigación (SIdI), Laboratorio de TXRF, Universidad Autónoma de Madrid, Madrid (Spain); Margui, Eva [Department of Chemistry, University of Girona, Girona (Spain); Streli, Christina [TU Wien, Atominstitut,Radiation Physics, Vienna (Austria); Pepponi, Giancarlo [Fondazione Bruno Kessler, Povo, Trento (Italy); Stosnach, Hagen [Bruker Nano GmbH, Berlin (Germany); Yamada, Takashi [Rigaku Corporation, Takatsuki, Osaka (Japan); Vandenabeele, Peter [Department of Archaeology, Ghent University, Ghent (Belgium); Maina, David M.; Gatari, Michael [Institute of Nuclear Science and Technology, University of Nairobi, Nairobi (Kenya); Shepherd, Keith D.; Towett, Erick K. [World Agroforestry Centre (ICRAF), Nairobi (Kenya); Bennun, Leonardo [Laboratorio de Física Aplicada, Departamento de Física, Universidad de Concepción (Chile); Custo, Graciela; Vasquez, Cristina [Gerencia Química, Laboratorio B025, Centro Atómico Constituyentes, San Martín (Argentina); Depero, Laura E., E-mail: laura.depero@unibs.it [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy)

    2014-11-01

    Total Reflection X-Ray Fluorescence (TXRF) is a mature technique to evaluate quantitatively the elemental composition of liquid samples deposited on clean and well polished reflectors. In this paper the results of the first worldwide TXRF round-robin test of water samples, involving 18 laboratories in 10 countries are presented and discussed. The test was performed within the framework of the VAMAS project, interlaboratory comparison of TXRF spectroscopy for environmental analysis, whose aim is to develop guidelines and a standard methodology for biological and environmental analysis by means of the TXRF analytical technique. - Highlights: • The discussion of the first worldwide TXRF round-robin test of water samples (18 laboratories of 10 countries) is reported. • Drinking, waste, and desalinated water samples were tested. • Data dispersion sources were identified: sample concentration, preparation, fitting procedure, and quantification. • The protocol for TXRF analysis of drinking water is proposed.

  17. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2011

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2011-01-21

    This document contains the calendar year 2011 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and the Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2011, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2011.

  18. Location of Urban Logistic Terminals as Hub Location Problem

    Directory of Open Access Journals (Sweden)

    Jasmina Pašagić Škrinjar

    2012-09-01

    Full Text Available In this paper the problems of locating urban logistic terminals are studied as hub location problems that due to a large number of potential nodes in big cities belong to hard non-polynomial problems, the so-called NP-problems. The hub location problems have found wide application in physical planning of transport and telecommunication systems, especially systems of fast delivery, networks of logistic and distribution centres and cargo traffic terminals of the big cities, etc. The paper defines single and multiple allocations and studies the numerical examples. The capacitated single allocation hub location problems have been studied, with the provision of a mathematical model of selecting the location for the hubs on the network. The paper also presents the differences in the possibilities of implementing the exact and heuristic methods to solve the actual location problems of big dimensions i.e. hub problems of the big cities.

  19. Aerosol Sampling System for Collection of Capstone Depleted Uranium Particles in a High-Energy Environment

    International Nuclear Information System (INIS)

    Holmes, Thomas D.; Guilmette, Raymond A.; Cheng, Yung-Sung; Parkhurst, MaryAnn; Hoover, Mark D.

    2009-01-01

    The Capstone Depleted Uranium Aerosol Study was undertaken to obtain aerosol samples resulting from a kinetic-energy cartridge with a large-caliber depleted uranium (DU) penetrator striking an Abrams or Bradley test vehicle. The sampling strategy was designed to (1) optimize the performance of the samplers and maintain their integrity in the extreme environment created during perforation of an armored vehicle by a DU penetrator, (2) collect aerosols as a function of time post-impact, and (3) obtain size-classified samples for analysis of chemical composition, particle morphology, and solubility in lung fluid. This paper describes the experimental setup and sampling methodologies used to achieve these objectives. Custom-designed arrays of sampling heads were secured to the inside of the target in locations approximating the breathing zones of the vehicle commander, loader, gunner, and driver. Each array was designed to support nine filter cassettes and nine cascade impactors mounted with quick-disconnect fittings. Shielding and sampler placement strategies were used to minimize sampler loss caused by the penetrator impact and the resulting fragments of eroded penetrator and perforated armor. A cyclone train was used to collect larger quantities of DU aerosol for chemical composition and solubility. A moving filter sample was used to obtain semicontinuous samples for depleted uranium concentration determination. Control for the air samplers was provided by five remotely located valve control and pressure monitoring units located inside and around the test vehicle. These units were connected to a computer interface chassis and controlled using a customized LabVIEW engineering computer control program. The aerosol sampling arrays and control systems for the Capstone study provided the needed aerosol samples for physicochemical analysis, and the resultant data were used for risk assessment of exposure to DU aerosol

  20. Solvent Hold Tank Sample Results for MCU-16-1247-1248-1249: August 2016 Monthly Sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-01-12

    Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-1247-1248-1249), pulled on 08/22/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1247-1248-1249 indicated the Isopar™L concentration is above its nominal level (101%). The extractant (MaxCalix) and the modifier (CS-7SB) are 7% and 9 % below their nominal concentrations. The suppressor (TiDG) is 63% below its nominal concentration. This analysis confirms the solvent may require the addition of TiDG, and possibly of modifier and MaxCalix to restore then to nominal levels. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended. At the time of writing this report, A solvent trim batch containing TiDG, modifier and MaxCalix, was added to the SHT (October 2016) and expect the concentration of these components to be at their nominal values.

  1. Characterizing Air Pollution Exposure Misclassification Errors Using Detailed Cell Phone Location Data

    Science.gov (United States)

    Yu, H.; Russell, A. G.; Mulholland, J. A.

    2017-12-01

    In air pollution epidemiologic studies with spatially resolved air pollution data, exposures are often estimated using the home locations of individual subjects. Due primarily to lack of data or logistic difficulties, the spatiotemporal mobility of subjects are mostly neglected, which are expected to result in exposure misclassification errors. In this study, we applied detailed cell phone location data to characterize potential exposure misclassification errors associated with home-based exposure estimation of air pollution. The cell phone data sample consists of 9,886 unique simcard IDs collected on one mid-week day in October, 2013 from Shenzhen, China. The Community Multi-scale Air Quality model was used to simulate hourly ambient concentrations of six chosen pollutants at 3 km spatial resolution, which were then fused with observational data to correct for potential modeling biases and errors. Air pollution exposure for each simcard ID was estimated by matching hourly pollutant concentrations with detailed location data for corresponding IDs. Finally, the results were compared with exposure estimates obtained using the home location method to assess potential exposure misclassification errors. Our results show that the home-based method is likely to have substantial exposure misclassification errors, over-estimating exposures for subjects with higher exposure levels and under-estimating exposures for those with lower exposure levels. This has the potential to lead to a bias-to-the-null in the health effect estimates. Our findings suggest that the use of cell phone data has the potential for improving the characterization of exposure and exposure misclassification in air pollution epidemiology studies.

  2. Legacy sample disposition project. Volume 2: Final report

    International Nuclear Information System (INIS)

    Gurley, R.N.; Shifty, K.L.

    1998-02-01

    This report describes the legacy sample disposition project at the Idaho Engineering and Environmental Laboratory (INEEL), which assessed Site-wide facilities/areas to locate legacy samples and owner organizations and then characterized and dispositioned these samples. This project resulted from an Idaho Department of Environmental Quality inspection of selected areas of the INEEL in January 1996, which identified some samples at the Test Reactor Area and Idaho Chemical Processing Plant that had not been characterized and dispositioned according to Resource Conservation and Recovery Act (RCRA) requirements. The objective of the project was to manage legacy samples in accordance with all applicable environmental and safety requirements. A systems engineering approach was used throughout the project, which included collecting the legacy sample information and developing a system for amending and retrieving the information. All legacy samples were dispositioned by the end of 1997. Closure of the legacy sample issue was achieved through these actions

  3. Results of detailed ground geophysical surveys for locating and differentiating waste structures in waste management area 'A' at Chalk River Laboratories, Ontario

    International Nuclear Information System (INIS)

    Tomsons, D.K.; Street, P.J.; Lodha, G.S.

    1999-01-01

    Waste Management Area 'A' (WMA 'A'), located in the outer area of the Chalk River Laboratories (CRL) was in use as a waste burial site from 1946 to 1955. Waste management structures include debris-filled trenches, concrete bunkers and miscellaneous contaminated solid materials, and ditches and pits used for liquid dispersal. In order to update historical records, it was proposed to conduct detailed ground geophysical surveys to define the locations of waste management structures in WMA 'A', assist in planning of the drilling and sampling program to provide ground truth for the geophysics investigation and to predict the nature and locations of unknown/undefined shallow structures. A detailed ground geophysical survey grid was established with a total of 127 grid lines, oriented NNE and spaced one metre apart. The geophysical surveys were carried out during August and September, 1996. The combination of geophysical tools used included the Geonics EM61 metal detector, the GSM-19 magnetometer/gradiometer and a RAMAC high frequency ground penetrating radar system. The geophysical surveys were successful in identifying waste management structures and in characterizing to some extent, the composition of the waste. The geophysical surveys are able to determine the presence of most of the known waste management structures, especially in the western and central portions of the grid which contain the majority of the metallic waste. The eastern portion of the grid has a completely different geophysical character. While historical records show that trenches were dug, they are far less evident in the geophysical record. There is clear evidence for a trench running between lines 30E and 63E at 70 m. There are indications from the radar survey of other trench-like structures in the eastern portion. EM61 data clearly show that there is far less metallic debris in the eastern portion. The geophysical surveys were also successful in identifying previously unknown locations of waste

  4. Locating Depots for Capacitated Vehicle Routing

    DEFF Research Database (Denmark)

    Gørtz, Inge Li; Nagarajan, Viswanath

    2016-01-01

    We study a location-routing problem in the context of capacitated vehicle routing. The input to the k-location capacitated vehicle routing problem (k-LocVRP) consists of a set of demand locations in a metric space and a fleet of k identical vehicles, each of capacity Q. The objective is to locate k...... depots, one for each vehicle, and compute routes for the vehicles so that all demands are satisfied and the total cost is minimized. Our main result is a constant-factor approximation algorithm for k-LocVRP. In obtaining this result, we introduce a common generalization of the k-median and minimum...... spanning tree problems (called k median forest), which might be of independent interest. We give a local-search based (3+ε)-approximation algorithm for k median forest, which leads to a (12+ε)-approximation algorithm for k-LocVRP, for any constant ε>0....

  5. Locating Depots for Capacitated Vehicle Routing

    DEFF Research Database (Denmark)

    Gørtz, Inge Li; Nagarajan, Viswanath

    2016-01-01

    depots, one for each vehicle, and compute routes for the vehicles so that all demands are satisfied and the total cost is minimized. Our main result is a constant-factor approximation algorithm for k-LocVRP. In obtaining this result, we introduce a common generalization of the k-median and minimum...... spanning tree problems (called k median forest), which might be of independent interest. We give a local-search based (3+ε)-approximation algorithm for k median forest, which leads to a (12+ε)-approximation algorithm for k-LocVRP, for any constant ε>0.......We study a location-routing problem in the context of capacitated vehicle routing. The input to the k-location capacitated vehicle routing problem (k-LocVRP) consists of a set of demand locations in a metric space and a fleet of k identical vehicles, each of capacity Q. The objective is to locate k...

  6. Solvent hold tank sample results for MCU-16-1317-1318-1319. September 2016 monthly sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-01-01

    Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-1317-1318-1319), pulled on 09/12/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1317-1318-1319 indicated the Isopar™L concentration is above its nominal level (102%). The extractant (MaxCalix) and the modifier (CS-7SB) are 5% and 10 % below their nominal concentrations. The suppressor (TiDG) is 77% below its nominal concentration. A summary of the concentration of the relevant solvent components is shown below. This analysis confirms the Isopar™ addition to the solvent in August. This analysis also indicates the solvent may require the addition of TiDG, and possibly of modifier to restore them to nominal levels.

  7. Sampling wild species to conserve genetic diversity

    Science.gov (United States)

    Sampling seed from natural populations of crop wild relatives requires choice of the locations to sample from and the amount of seed to sample. While this may seem like a simple choice, in fact careful planning of a collector’s sampling strategy is needed to ensure that a crop wild collection will ...

  8. Characterization of a low-level radioactive waste grout: Sampling and test results

    International Nuclear Information System (INIS)

    Martin, P.F.C.; Lokken, R.O.

    1992-12-01

    WHC manages and operates the grout treatment facility at Hanford as part of a DOE program to clean up wastes stored at federal nuclear production sites. PNL provides support to the grout disposal program through pilot-scale tests, performance assessments, and formulation verification activities. in 1988 and 1989, over one million gallons of a low-level radioactive liquid waste was processed through the facility to produce a grout waste that was then deposited in an underground vault. The liquid waste was phosphate/sulfate waste (PSW) generated in decontamination of the N Reactor. PNL sampled and tested the grout produced during the second half of the PSW campaign to support quality verification activities prior to grout vault closure. Samples of grout were obtained by inserting nested-tube samplers into the grout slurry in the vault. After the grout had cured, the inner tube of the sampler was removed and the grout samples extracted. Tests for compressive strength, sonic velocity, and leach testing were used to assess grout quality; results were compared to those from pilot-scale test grouts made with a simulated PSW. The grout produced during the second half of the PSW campaign exceeded compressive strength and leachability formulation criteria. The nested tube samplers were effective in collecting samples of grout although their use introduced greater variability into the compressive strength data

  9. Surveying immigrants without sampling frames - evaluating the success of alternative field methods.

    Science.gov (United States)

    Reichel, David; Morales, Laura

    2017-01-01

    This paper evaluates the sampling methods of an international survey, the Immigrant Citizens Survey, which aimed at surveying immigrants from outside the European Union (EU) in 15 cities in seven EU countries. In five countries, no sample frame was available for the target population. Consequently, alternative ways to obtain a representative sample had to be found. In three countries 'location sampling' was employed, while in two countries traditional methods were used with adaptations to reach the target population. The paper assesses the main methodological challenges of carrying out a survey among a group of immigrants for whom no sampling frame exists. The samples of the survey in these five countries are compared to results of official statistics in order to assess the accuracy of the samples obtained through the different sampling methods. It can be shown that alternative sampling methods can provide meaningful results in terms of core demographic characteristics although some estimates differ to some extent from the census results.

  10. Location, location, location: does early cancer in Barrett's esophagus have a preference?

    Science.gov (United States)

    Enestvedt, Brintha K; Lugo, Ricardo; Guarner-Argente, Carlos; Shah, Pari; Falk, Gary W; Furth, Emma; Ginsberg, Gregory G

    2013-09-01

    Early cancer (high-grade dysplasia [HGD] and intramucosal carcinoma [ImCa]) associated with Barrett's esophagus (BE) may have a circumferential spatial predilection. To describe the esophageal circumferential location of early cancer in BE. Retrospective study, single tertiary referral center. One hundred nineteen patients were referred for endoscopic eradication therapy for early cancer associated with BE. Endoscopic images and reports and pathology were reviewed. Circumferential location designation of early cancer in BE by using a clock-face orientation. One hundred nineteen of 131 patients referred for endoscopic eradication therapy had a location designation for their advanced histology (91.9%). There were a total of 57 patients (47.9%) with HGD and 62 patients (52.1%) with ImCa. There was a significantly higher rate of early cancer (HGD or ImCa) in the right hemisphere (12 to 6 o'clock location) compared with the left hemisphere (84.9% vs 15.1%, P cancer was found in the 12 to 3 o'clock quadrant (64.7%); 71.9% of HGD and 58.1% of ImCa lesions were located in the 12 to 3 o'clock quadrant. Retrospective design, single center. Early cancer associated with BE is far more commonly found in the right hemisphere of the esophagus (12 to 6 o'clock) with the highest rate in the 12 to 3 o'clock quadrant. These findings support enhanced scrutiny of the right hemisphere of the esophagus during surveillance and endoscopic treatment of patients with BE. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  11. Retained Gas Sampling Results for the Flammable Gas Program

    International Nuclear Information System (INIS)

    Bates, J.M.; Mahoney, L.A.; Dahl, M.E.; Antoniak, Z.I.

    1999-01-01

    The key phenomena of the Flammable Gas Safety Issue are generation of the gas mixture, the modes of gas retention, and the mechanisms causing release of the gas. An understanding of the mechanisms of these processes is required for final resolution of the safety issue. Central to understanding is gathering information from such sources as historical records, tank sampling data, tank process data (temperatures, ventilation rates, etc.), and laboratory evaluations conducted on tank waste samples

  12. Retained Gas Sampling Results for the Flammable Gas Program

    Energy Technology Data Exchange (ETDEWEB)

    J.M. Bates; L.A. Mahoney; M.E. Dahl; Z.I. Antoniak

    1999-11-18

    The key phenomena of the Flammable Gas Safety Issue are generation of the gas mixture, the modes of gas retention, and the mechanisms causing release of the gas. An understanding of the mechanisms of these processes is required for final resolution of the safety issue. Central to understanding is gathering information from such sources as historical records, tank sampling data, tank process data (temperatures, ventilation rates, etc.), and laboratory evaluations conducted on tank waste samples.

  13. Semi-annual sampling of Fourmile Branch and its seeplines in the F and H Areas of SRS: July 1992

    International Nuclear Information System (INIS)

    Dixon, K.L.; Rogers, V.A.

    1994-04-01

    In July 1992, water samples were collected from Fourmile Branch (FMB) and its seeplines in the vicinity of the F and H-Area seepage basins. The samples were collected from five seepline locations in F Area, five seepline locations in H Area, and three stream locations on FMB. The sampling event was the first in a series of three semi-annual sampling event was the first in a series of three semi-annual sampling events aimed at characterizing the shallow groundwater outcropping into FMB and its wetlands. In the past, this groundwater has been shown to contain contaminants migrating from the F- and H-Area seepage basins. The samples were analyzed for Appendix 9 metals, various radionuclides, selected volatile compounds, and selected inorganic constituents and parameters. Results from the July 1992 sampling event suggest that the seeplines in both F and H Areas and FMB continue to be influenced by contaminants migrating from the F- and H-Area seepage basins. However, when compared to 1989 measurements, the concentrations of most of the constituents have declined. Contaminant concentration measured in July 1992 were compared to primary drinking water standards (PDWS), secondary drinking water standards (SDWS), and maximum contaminant levels (MCL) enforceable in 1993. Results were also compared to 1989 measurements at corresponding sampling locations and to background samples collected as part of the July 1992 sampling event. Using two different statistical tests, concentrations of selected F- and H-Area seepline analytes were compared to background samples. These tests were designed to detect if concentrations of contaminants along the F- and H-Area seeplines were greater than background concentrations

  14. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2007

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2007-01-31

    This document contains the calendar year 2007 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis and may not be collected in 2007 in which case the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2007.

  15. Heavy Metals Speciation in Dust Samples from Various Parts of ...

    African Journals Online (AJOL)

    Dust on our roads constitutes a major source of environmental hazard. Little attention is paid to the enormous challenges resulting from its polluting effect and health implications. In this investigation, twenty five dust samples were collected from 5 locations within Ebonyi North, South and Central Senatorial Zones between ...

  16. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L E

    1992-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Ground-Water Monitoring Project. Samples for radiological analyses include Air-Particulate Filter, gases and vapor; Water/Columbia River, Onsite Pond, Spring, Irrigation, and Drinking; Foodstuffs/Animal Products including Whole Milk, Poultry and Eggs, and Beef; Foodstuffs/Produce including Leafy Vegetables, Vegetables, and Fruit; Foodstuffs/Farm Products including Wine, Wheat and Alfalfa; Wildlife; Soil; Vegetation; and Sediment. Direct Radiation Measurements include Terrestrial Locations, Columbia River Shoreline Locations, and Onsite Roadway, Railway and Aerial, Radiation Surveys.

  17. Reporting altered test results in hemolyzed samples: is the cure worse than the disease?

    Science.gov (United States)

    Lippi, Giuseppe; Cervellin, Gianfranco; Plebani, Mario

    2017-07-26

    The management of laboratory data in unsuitable (hemolyzed) samples remains an almost unresolved dilemma. Whether or not laboratory test results obtained by measuring unsuitable specimens should be made available to the clinicians has been the matter of fierce debates over the past decades. Recently, an intriguing alternative to suppressing test results and recollecting the specimen has been put forward, entailing the definition and implementation of specific algorithms that would finally allow reporting a preanalytically altered laboratory value within a specific comment about its uncertainty of measurement. This approach carries some advantages, namely the timely communication of potentially life-threatening laboratory values, but also some drawbacks. These especially include the challenging definition of validated performance specifications for hemolyzed samples, the need to producing reliable data with the lowest possible uncertainty, the short turnaround time for repeating most laboratory tests, the risk that the comments may be overlooked in short-stay and frequently overcrowded units (e.g. the emergency department), as well as the many clinical advantages of a direct communication with the physician in charge of the patient. Despite the debate remains open, we continue supporting the suggestion that suppressing data in unsuitable (hemolyzed) samples and promptly notifying the clinicians about the need to recollect the samples remains the most (clinically and analytically) safe practice.

  18. Hanford Site Environmental Surveillance Master Sampling Schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1999-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1, ''General Environmental protection Program,'' and DOE Order 5400.5, ''Radiation Protection of the Public and the Environment.'' The sampling methods are described in the Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office, DOE/RL-91-50, Rev.2, U.S. Department of Energy, Richland, Washington. This document contains the CY1999 schedules for the routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section includes the sampling location, sample type, and analyses to be performed on the sample. In some cases, samples are scheduled on a rotating basis and may not be collected in 1999 in which case the anticipated year for collection is provided. In addition, a map is included for each media showing approximate sampling locations

  19. Air-sampling inlet contamination by aircraft emissions on the NASA CV-990 aircraft

    Science.gov (United States)

    Condon, E. P.; Vedder, J. F.

    1984-01-01

    Results of an experimental investigation of the contamination of air sampling inlets by aircraft emissions from the NASA CV-990 research aircraft are presented. This four-engine jet aircraft is a NASA facility used for many different atmospheric and meteorological experiments, as well as for developing spacecraft instrumentation for remote measurements. Our investigations were performed to provide information on which to base the selection of sampling locations for a series of multi-instrument missions for measuring tropospheric trace gases. The major source of contamination is the exhaust from the jet engines, which generate many of the same gases that are of interest in atmospheric chemistry, as well as other gases that may interfere with sampling measurements. The engine exhaust contains these gases in mixing ratios many orders of magnitude greater than those that occur in the clean atmosphere which the missions seek to quantify. Pressurized samples of air were collected simultaneously from a scoop located forward of the engines to represent clean air and from other multiport scoops at various aft positions on the aircraft. The air samples were analyzed in the laboratory by gas chromatography for carbon monoxide, an abundant combustion by-product. Data are presented for various scoop locations under various flight conditions.

  20. Shock-induced explosive chemistry in a deterministic sample configuration.

    Energy Technology Data Exchange (ETDEWEB)

    Stuecker, John Nicholas; Castaneda, Jaime N.; Cesarano, Joseph, III (,; ); Trott, Wayne Merle; Baer, Melvin R.; Tappan, Alexander Smith

    2005-10-01

    Explosive initiation and energy release have been studied in two sample geometries designed to minimize stochastic behavior in shock-loading experiments. These sample concepts include a design with explosive material occupying the hole locations of a close-packed bed of inert spheres and a design that utilizes infiltration of a liquid explosive into a well-defined inert matrix. Wave profiles transmitted by these samples in gas-gun impact experiments have been characterized by both velocity interferometry diagnostics and three-dimensional numerical simulations. Highly organized wave structures associated with the characteristic length scales of the deterministic samples have been observed. Initiation and reaction growth in an inert matrix filled with sensitized nitromethane (a homogeneous explosive material) result in wave profiles similar to those observed with heterogeneous explosives. Comparison of experimental and numerical results indicates that energetic material studies in deterministic sample geometries can provide an important new tool for validation of models of energy release in numerical simulations of explosive initiation and performance.

  1. Methods for confidence interval estimation of a ratio parameter with application to location quotients

    Directory of Open Access Journals (Sweden)

    Beyene Joseph

    2005-10-01

    Full Text Available Abstract Background The location quotient (LQ ratio, a measure designed to quantify and benchmark the degree of relative concentration of an activity in the analysis of area localization, has received considerable attention in the geographic and economics literature. This index can also naturally be applied in the context of population health to quantify and compare health outcomes across spatial domains. However, one commonly observed limitation of LQ is its widespread use as only a point estimate without an accompanying confidence interval. Methods In this paper we present statistical methods that can be used to construct confidence intervals for location quotients. The delta and Fieller's methods are generic approaches for a ratio parameter and the generalized linear modelling framework is a useful re-parameterization particularly helpful for generating profile-likelihood based confidence intervals for the location quotient. A simulation experiment is carried out to assess the performance of each of the analytic approaches and a health utilization data set is used for illustration. Results Both the simulation results as well as the findings from the empirical data show that the different analytical methods produce very similar confidence limits for location quotients. When incidence of outcome is not rare and sample sizes are large, the confidence limits are almost indistinguishable. The confidence limits from the generalized linear model approach might be preferable in small sample situations. Conclusion LQ is a useful measure which allows quantification and comparison of health and other outcomes across defined geographical regions. It is a very simple index to compute and has a straightforward interpretation. Reporting this estimate with appropriate confidence limits using methods presented in this paper will make the measure particularly attractive for policy and decision makers.

  2. Sample pre-concentration with high enrichment factors at a fixed location in paper-based microfluidic devices.

    Science.gov (United States)

    Yeh, Shih-Hao; Chou, Kuang-Hua; Yang, Ruey-Jen

    2016-03-07

    The lack of sensitivity is a major problem among microfluidic paper-based analytical devices (μPADs) for early disease detection and diagnosis. Accordingly, the present study presents a method for improving the enrichment factor of low-concentration biomarkers by using shallow paper-based channels realized through a double-sided wax-printing process. In addition, the enrichment factor is further enhanced by exploiting the ion concentration polarization (ICP) effect on the cathodic side of the nanoporous membrane, in which a stationary sample plug is obtained. The occurrence of ICP on the shallow-channel μPAD is confirmed by measuring the current-voltage response as the external voltage is increased from 0 to 210 V (or the field strength from 0 to 1.05 × 10(4) V m(-1)) over 600 s. In addition, to the best of our knowledge, the electroosmotic flow (EOF) speed on the μPAD fabricated with a wax-channel is measured for the first time using a current monitoring method. The experimental results show that for a fluorescein sample, the concentration factor is increased from 130-fold in a conventional full-thickness paper channel to 944-fold in the proposed shallow channel. Furthermore, for a fluorescein isothiocyanate-labeled bovine serum albumin (FITC-BSA) sample, the proposed shallow-channel μPAD achieves an 835-fold improvement in the concentration factor. The concentration technique presented here provides a novel strategy for enhancing the detection sensitivity of μPAD applications.

  3. Biota dose assessment of small mammals sampled near uranium mines in northern Arizona

    Energy Technology Data Exchange (ETDEWEB)

    Jannik, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Minter, K. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Kuhne, W. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Kubilius, W. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2018-01-09

    In 2015, the U. S. Geological Survey (USGS) collected approximately 50 small mammal carcasses from Northern Arizona uranium mines and other background locations. Based on the highest gross alpha results, 11 small mammal samples were selected for radioisotopic analyses. None of the background samples had significant gross alpha results. The 11 small mammals were identified relative to the three ‘indicator’ mines located south of Fredonia, AZ on the Kanab Plateau (Kanab North Mine, Pinenut Mine, and Arizona 1 Mine) (Figure 1-1) and are operated by Energy Fuels Resources Inc. (EFRI). EFRI annually reports soil analysis for uranium and radium-226 using Arizona Department of Environmental Quality (ADEQ)-approved Standard Operating Procedures for Soil Sampling (EFRI 2016a, 2016b, 2017). In combination with the USGS small mammal radioiosotopic tissue analyses, a biota dose assessment was completed by Savannah River National Laboratory (SRNL) using the RESidual RADioactivity-BIOTA (RESRAD-BIOTA, V. 1.8) dose assessment tool provided by the Argonne National Laboratory (ANL 2017).

  4. Remote sampling and analysis of highly radioactive samples in shielded boxes

    International Nuclear Information System (INIS)

    Kirpikov, D.A.; Miroshnichenko, I.V.; Pykhteev, O.Yu.

    2010-01-01

    The sampling procedure used for highly radioactive coolant water is associated with high risk of personnel irradiation and uncontrolled radioactive contamination. Remote sample manipulation with provision for proper radiation shielding is intended for safety enhancement of the sampling procedure. The sampling lines are located in an isolated compartment, a shielded box. Various equipment which enables remote or automatic sample manipulation is used for this purpose. The main issues of development of the shielded box equipment intended for a wider ranger of remote chemical analyses and manipulation techniques for highly radioactive water samples are considered in the paper. There were three principal directions of work: Transfer of chemical analysis performed in the laboratory inside the shielded box; Prevalence of computer-aided and remote techniques of highly radioactive sample manipulation inside the shielded box; and, Increase in control over sampling and determination of thermal-hydraulic parameters of the coolant water in the sampling lines. The developed equipment and solutions enable remote chemical analysis in the restricted volume of the shielded box by using ion-chromatographic, amperometrical, fluorimetric, flow injection, phototurbidimetric, conductometric and potentiometric methods. Extent of control performed in the shielded box is determined taking into account the requirements of the regulatory documents as well as feasibility and cost of the technical adaptation of various methods to the shielded box conditions. The work resulted in highly precise determination of more than 15 indexes of the coolant water quality performed in on-line mode in the shielded box. It averages to 80% of the total extent of control performed at the prototype reactor plants. The novel solutions for highly radioactive sample handling are implemented in the shielded box (for example, packaging, sample transportation to the laboratory, volume measurement). The shielded box is

  5. Understanding the Representativeness of Mobile Phone Location Data in Characterizing Human Mobility Indicators

    Directory of Open Access Journals (Sweden)

    Shiwei Lu

    2017-01-01

    Full Text Available The advent of big data has aided understanding of the driving forces of human mobility, which is beneficial for many fields, such as mobility prediction, urban planning, and traffic management. However, the data sources used in many studies, such as mobile phone location and geo-tagged social media data, are sparsely sampled in the temporal scale. An individual’s records can be distributed over a few hours a day, or a week, or over just a few hours a month. Thus, the representativeness of sparse mobile phone location data in characterizing human mobility requires analysis before using data to derive human mobility patterns. This paper investigates this important issue through an approach that uses subscriber mobile phone location data collected by a major carrier in Shenzhen, China. A dataset of over 5 million mobile phone subscribers that covers 24 h a day is used as a benchmark to test the representativeness of mobile phone location data on human mobility indicators, such as total travel distance, movement entropy, and radius of gyration. This study divides this dataset by hour, using 2- to 23-h segments to evaluate the representativeness due to the availability of mobile phone location data. The results show that different numbers of hourly segments affect estimations of human mobility indicators and can cause overestimations or underestimations from the individual perspective. On average, the total travel distance and movement entropy tend to be underestimated. The underestimation coefficient results for estimation of total travel distance are approximately linear, declining as the number of time segments increases, and the underestimation coefficient results for estimating movement entropy decline logarithmically as the time segments increase, whereas the radius of gyration tends to be more ambiguous due to the loss of isolated locations. This paper suggests that researchers should carefully interpret results derived from this type of

  6. Inferring Groups of Objects, Preferred Routes, and Facility Locations from Trajectories

    DEFF Research Database (Denmark)

    Ceikute, Vaida

    (i) infer groups of objects traveling together, (ii) determine routes preferred by local drivers, and (iii) identify attractive facility locations. First, we present framework that efficiently supports online discovery of groups of moving objects that travel together. We adopt a sampling......-independent approach that makes no assumptions about when object positions are sampled and that supports the use of approximate trajectories. The framework’s algorithms exploit density-based clustering to identify groups. Such identified groups are scored based on cardinality and duration. With the use of domination...... and similarity notions, groups of low interest are pruned, and a variety of different, interesting groups are returned. Results from empirical studies with real and synthetic data offer insight into the effectiveness and efficiency of the proposed framework. Next, we view GPS trajectories as trips that represent...

  7. Analysis and radiological assessment of survey results and samples from the beaches around Sellafield

    International Nuclear Information System (INIS)

    Webb, G.A.M.; Fry, F.A.

    1983-12-01

    After radioactive sea debris had been found on beaches near the BNFL, Sellafield, plant, NRPB was asked by the Department of the Environment to analyse some of the samples collected and to assess the radiological hazard to members of the public. A report is presented containing an analysis of survey reports for the period 19 November - 4 December 1983 and preliminary results of the analysis of all samples received, together with the Board's recommendations. (author)

  8. Semantic Location Extraction from Crowdsourced Data

    Science.gov (United States)

    Koswatte, S.; Mcdougall, K.; Liu, X.

    2016-06-01

    Crowdsourced Data (CSD) has recently received increased attention in many application areas including disaster management. Convenience of production and use, data currency and abundancy are some of the key reasons for attracting this high interest. Conversely, quality issues like incompleteness, credibility and relevancy prevent the direct use of such data in important applications like disaster management. Moreover, location information availability of CSD is problematic as it remains very low in many crowd sourced platforms such as Twitter. Also, this recorded location is mostly related to the mobile device or user location and often does not represent the event location. In CSD, event location is discussed descriptively in the comments in addition to the recorded location (which is generated by means of mobile device's GPS or mobile communication network). This study attempts to semantically extract the CSD location information with the help of an ontological Gazetteer and other available resources. 2011 Queensland flood tweets and Ushahidi Crowd Map data were semantically analysed to extract the location information with the support of Queensland Gazetteer which is converted to an ontological gazetteer and a global gazetteer. Some preliminary results show that the use of ontologies and semantics can improve the accuracy of place name identification of CSD and the process of location information extraction.

  9. SEMANTIC LOCATION EXTRACTION FROM CROWDSOURCED DATA

    Directory of Open Access Journals (Sweden)

    S. Koswatte

    2016-06-01

    Full Text Available Crowdsourced Data (CSD has recently received increased attention in many application areas including disaster management. Convenience of production and use, data currency and abundancy are some of the key reasons for attracting this high interest. Conversely, quality issues like incompleteness, credibility and relevancy prevent the direct use of such data in important applications like disaster management. Moreover, location information availability of CSD is problematic as it remains very low in many crowd sourced platforms such as Twitter. Also, this recorded location is mostly related to the mobile device or user location and often does not represent the event location. In CSD, event location is discussed descriptively in the comments in addition to the recorded location (which is generated by means of mobile device's GPS or mobile communication network. This study attempts to semantically extract the CSD location information with the help of an ontological Gazetteer and other available resources. 2011 Queensland flood tweets and Ushahidi Crowd Map data were semantically analysed to extract the location information with the support of Queensland Gazetteer which is converted to an ontological gazetteer and a global gazetteer. Some preliminary results show that the use of ontologies and semantics can improve the accuracy of place name identification of CSD and the process of location information extraction.

  10. Sparse sampling and reconstruction for electron and scanning probe microscope imaging

    Science.gov (United States)

    Anderson, Hyrum; Helms, Jovana; Wheeler, Jason W.; Larson, Kurt W.; Rohrer, Brandon R.

    2015-07-28

    Systems and methods for conducting electron or scanning probe microscopy are provided herein. In a general embodiment, the systems and methods for conducting electron or scanning probe microscopy with an undersampled data set include: driving an electron beam or probe to scan across a sample and visit a subset of pixel locations of the sample that are randomly or pseudo-randomly designated; determining actual pixel locations on the sample that are visited by the electron beam or probe; and processing data collected by detectors from the visits of the electron beam or probe at the actual pixel locations and recovering a reconstructed image of the sample.

  11. Protein (multi-)location prediction: utilizing interdependencies via a generative model

    Science.gov (United States)

    Shatkay, Hagit

    2015-01-01

    Motivation: Proteins are responsible for a multitude of vital tasks in all living organisms. Given that a protein’s function and role are strongly related to its subcellular location, protein location prediction is an important research area. While proteins move from one location to another and can localize to multiple locations, most existing location prediction systems assign only a single location per protein. A few recent systems attempt to predict multiple locations for proteins, however, their performance leaves much room for improvement. Moreover, such systems do not capture dependencies among locations and usually consider locations as independent. We hypothesize that a multi-location predictor that captures location inter-dependencies can improve location predictions for proteins. Results: We introduce a probabilistic generative model for protein localization, and develop a system based on it—which we call MDLoc—that utilizes inter-dependencies among locations to predict multiple locations for proteins. The model captures location inter-dependencies using Bayesian networks and represents dependency between features and locations using a mixture model. We use iterative processes for learning model parameters and for estimating protein locations. We evaluate our classifier MDLoc, on a dataset of single- and multi-localized proteins derived from the DBMLoc dataset, which is the most comprehensive protein multi-localization dataset currently available. Our results, obtained by using MDLoc, significantly improve upon results obtained by an initial simpler classifier, as well as on results reported by other top systems. Availability and implementation: MDLoc is available at: http://www.eecis.udel.edu/∼compbio/mdloc. Contact: shatkay@udel.edu. PMID:26072505

  12. Emergence of chikungunya seropositivity in healthy Malaysian adults residing in outbreak-free locations: Chikungunya seroprevalence results from the Malaysian Cohort

    Science.gov (United States)

    2013-01-01

    Background In 1998, Malaysia experienced its first chikungunya virus (CHIKV) outbreak in the suburban areas followed by another two in 2006 (rural areas) and 2008 (urban areas), respectively. Nevertheless, there is still a lack of documented data regarding the magnitude of CHIKV exposure in the Malaysian population. The aim of this study was to determine the extent of chikungunya virus infection in healthy Malaysian adults residing in outbreak-free locations. Methods A cross sectional study of chikungunya (CHIK) seroprevalence was carried out in 2009 amongst The Malaysian Cohort participants living in four states (Kuala Lumpur, Selangor, Pahang and Negeri Sembilan). A total of 945 participants were randomly identified for the study. Potential risk factors for CHIK infection were determined via questionnaires, and IgG antibodies against CHIK were detected by an enzyme-linked immunosorbent assay. Logistic regression identified risk factors associated with CHIK seropositivity, while geographical information system was used for visual and spatial analysis. Results From the 945 serum samples tested, 5.9% was positive for CHIK IgG. Being male, Malay, rural occupancy and Negeri Sembilan residency were identified as univariate predictors for CHIK seropositivity, while multivariate analysis identified being male and rural occupancy as risk factors. Conclusions This study provided evidence that CHIK is slowly emerging in Malaysia. Although the current baseline seroprevalence is low in this country, increasing number of CHIK cases reported to the Malaysia Ministry of Health imply the possibility of CHIK virus becoming endemic in Malaysia. PMID:23379541

  13. UMTRA project water sampling and analysis plan, Naturita, Colorado

    International Nuclear Information System (INIS)

    1994-04-01

    Surface remedial action is scheduled to begin at the Naturita UMTRA Project processing site in the spring of 1994. No water sampling was performed during 1993 at either the Naturita processing site (NAT-01) or the Dry Flats disposal site (NAT-12). Results of previous water sampling at the Naturita processing site indicate that ground water in the alluvium is contaminated as a result of uranium processing activities. Baseline ground water conditions have been established in the uppermost aquifer at the Dry Flats disposal site. Water sampling activities scheduled for April 1994 include preconstruction sampling of selected monitor wells at the processing site, surface water sampling of the San Miguel River, sampling of several springs/seeps in the vicinity of the disposal site, and sampling of two monitor wells in Coke Oven Valley. The monitor well locations provide sampling points to characterize ground water quality and flow conditions in the vicinity of the sites. The list of analytes has been updated to reflect constituents related to uranium processing activities and the parameters needed for geochemical evaluation. Water sampling will be conducted annually at minimum during the period of construction activities

  14. Enhancing source location protection in wireless sensor networks

    Science.gov (United States)

    Chen, Juan; Lin, Zhengkui; Wu, Di; Wang, Bailing

    2015-12-01

    Wireless sensor networks are widely deployed in the internet of things to monitor valuable objects. Once the object is monitored, the sensor nearest to the object which is known as the source informs the base station about the object's information periodically. It is obvious that attackers can capture the object successfully by localizing the source. Thus, many protocols have been proposed to secure the source location. However, in this paper, we examine that typical source location protection protocols generate not only near but also highly localized phantom locations. As a result, attackers can trace the source easily from these phantom locations. To address these limitations, we propose a protocol to enhance the source location protection (SLE). With phantom locations far away from the source and widely distributed, SLE improves source location anonymity significantly. Theory analysis and simulation results show that our SLE provides strong source location privacy preservation and the average safety period increases by nearly one order of magnitude compared with existing work with low communication cost.

  15. Earthquake location in island arcs

    Science.gov (United States)

    Engdahl, E.R.; Dewey, J.W.; Fujita, K.

    1982-01-01

    A comprehensive data set of selected teleseismic P-wave arrivals and local-network P- and S-wave arrivals from large earthquakes occurring at all depths within a small section of the central Aleutians is used to examine the general problem of earthquake location in island arcs. Reference hypocenters for this special data set are determined for shallow earthquakes from local-network data and for deep earthquakes from combined local and teleseismic data by joint inversion for structure and location. The high-velocity lithospheric slab beneath the central Aleutians may displace hypocenters that are located using spherically symmetric Earth models; the amount of displacement depends on the position of the earthquakes with respect to the slab and on whether local or teleseismic data are used to locate the earthquakes. Hypocenters for trench and intermediate-depth events appear to be minimally biased by the effects of slab structure on rays to teleseismic stations. However, locations of intermediate-depth events based on only local data are systematically displaced southwards, the magnitude of the displacement being proportional to depth. Shallow-focus events along the main thrust zone, although well located using only local-network data, are severely shifted northwards and deeper, with displacements as large as 50 km, by slab effects on teleseismic travel times. Hypocenters determined by a method that utilizes seismic ray tracing through a three-dimensional velocity model of the subduction zone, derived by thermal modeling, are compared to results obtained by the method of joint hypocenter determination (JHD) that formally assumes a laterally homogeneous velocity model over the source region and treats all raypath anomalies as constant station corrections to the travel-time curve. The ray-tracing method has the theoretical advantage that it accounts for variations in travel-time anomalies within a group of events distributed over a sizable region of a dipping, high

  16. Results for the Fourth Quarter Calendar Year 2015 Tank 50H Salt Solution Sample

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-01-11

    In this memorandum, the chemical and radionuclide contaminant results from the Fourth Quarter Calendar Year 2015 (CY15) sample of Tank 50H salt solution are presented in tabulated form. The Fourth Quarter CY15 Tank 50H samples were obtained on October 29, 2015 and received at Savannah River National Laboratory (SRNL) on October 30, 2015. The information from this characterization will be used by Defense Waste Processing Facility (DWPF) & Saltstone Facility Engineering for the transfer of aqueous waste from Tank 50H to the Salt Feed Tank in the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility. This memorandum compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the Task Technical and Quality Assurance Plan (TTQAP) for the Tank 50H saltstone task. The chemical and radionuclide contaminant results from the characterization of the Fourth Quarter Calendar Year 2015 (CY15) sampling of Tank 50H were requested by SRR personnel and details of the testing are presented in the SRNL Task Technical and Quality Assurance Plan.

  17. Magnetostratigraphy in the Lodo Formation, CA: An Attempt to Locate Hyperthermals of the Early Eocene

    Science.gov (United States)

    Aldrich, N. C.; Pluhar, C. J.; Gibbs, S.; Rieth, J. A.

    2015-12-01

    The Lodo Formation in the California Coast Range, Fresno County records the Paleocene Eocene Thermal Maximum (PETM) and possibly other Early Eocene hyperthermal events. The Eocene Thermal Maximum 2 (ETM2, ELMO, or H1) represents a hyperthermal event that occurred approximately 2 million years after the PETM and just prior to the C24r - C24n magnetic reversal (≈ 53.9 Ma) in the Ypresian. While the ETM2 event has been located in offshore samples, it has been more difficult to locate in a terrestrial section. This project attempts to locate the ETM2 magnetostratigraphically by finding the paleomagnetic reversal at C24r-C24n.3n, provide geochronological framework, and assess sedimentation rate changes during this time. This area is known to have had a high rate of deposition (16.8 cm/kyr ) during the PETM, which is found lower in the section. We collected 36 new samples from a 13.44m section spanning stratigraphy thought to cover the ETM2 along with 31 previous samples spanning the PETM, and prepared them for paleomagnetic and paleontological analysis. We analyzed samples using standard paleomagnetic methods including low-temperature and thermal demagnetization. Preliminary results suggest that the magnetostratigraphy spans the C24r-C24n boundary, while the micropaleontology shows the NP10-NP11 boundary, which occurs near the ETM2 as well as the NP11-NP12 boundary. The data indicate an order-of-magnitude drop in sedimentation rate in the lower Eocene at this site, concomitant with a drop in grain size, compared with the PETM.

  18. Compilation of PRF Canyon Floor Pan Sample Analysis Results

    Energy Technology Data Exchange (ETDEWEB)

    Pool, Karl N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Minette, Michael J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wahl, Jon H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Greenwood, Lawrence R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Coffey, Deborah S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McNamara, Bruce K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bryan, Samuel A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Scheele, Randall D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Delegard, Calvin H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sinkov, Sergey I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Soderquist, Chuck Z. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fiskum, Sandra K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Brown, Garrett N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Clark, Richard A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-06-30

    On September 28, 2015, debris collected from the PRF (236-Z) canyon floor, Pan J, was observed to exhibit chemical reaction. The material had been transferred from the floor pan to a collection tray inside the canyon the previous Friday. Work in the canyon was stopped to allow Industrial Hygiene to perform monitoring of the material reaction. Canyon floor debris that had been sealed out was sequestered at the facility, a recovery plan was developed, and drum inspections were initiated to verify no additional reactions had occurred. On October 13, in-process drums containing other Pan J material were inspected and showed some indication of chemical reaction, limited to discoloration and degradation of inner plastic bags. All Pan J material was sealed back into the canyon and returned to collection trays. Based on the high airborne levels in the canyon during physical debris removal, ETGS (Encapsulation Technology Glycerin Solution) was used as a fogging/lock-down agent. On October 15, subject matter experts confirmed a reaction had occurred between nitrates (both Plutonium Nitrate and Aluminum Nitrate Nonahydrate (ANN) are present) in the Pan J material and the ETGS fixative used to lower airborne radioactivity levels during debris removal. Management stopped the use of fogging/lock-down agents containing glycerin on bulk materials, declared a Management Concern, and initiated the Potential Inadequacy in the Safety Analysis determination process. Additional drum inspections and laboratory analysis of both reacted and unreacted material are planned. This report compiles the results of many different sample analyses conducted by the Pacific Northwest National Laboratory on samples collected from the Plutonium Reclamation Facility (PRF) floor pans by the CH2MHill’s Plateau Remediation Company (CHPRC). Revision 1 added Appendix G that reports the results of the Gas Generation Rate and methodology. The scope of analyses requested by CHPRC includes the determination of

  19. Statistical evaluation of the data obtained from the K East Basin Sandfilter Backwash Pit samples

    International Nuclear Information System (INIS)

    Welsh, T.L.

    1994-01-01

    Samples were obtained from different locations from the K Each Sandfilter Backwash Pit to characterize the sludge material. These samples were analyzed chemically for elements, radionuclides, and residual compounds. The analytical results were statistically analyzed to determine the mean analyte content and the associated variability for each mean value

  20. Hanford Site Environmental Surveillance Master Sampling Schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    2000-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1, General Environmental Protection Program: and DOE Order 5400.5, Radiation Protection of the Public and the Environment. The sampling design is described in the Operations Office, Environmental Monitoring Plan, United States Department of Energy, Richland DOE/RL-91-50, Rev.2, U.S. Department of Energy, Richland, Washington. This document contains the CY 2000 schedules for the routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section includes sampling locations, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis and may not be collected in 2000 in which case the anticipated year for collection is provided. In addition, a map showing approximate sampling locations is included for each media scheduled for collection

  1. SAPLE: Sandia Advanced Personnel Locator Engine.

    Energy Technology Data Exchange (ETDEWEB)

    Procopio, Michael J.

    2010-04-01

    We present the Sandia Advanced Personnel Locator Engine (SAPLE) web application, a directory search application for use by Sandia National Laboratories personnel. SAPLE's purpose is to return Sandia personnel 'results' as a function of user search queries, with its mission to make it easier and faster to find people at Sandia. To accomplish this, SAPLE breaks from more traditional directory application approaches by aiming to return the correct set of results while placing minimal constraints on the user's query. Two key features form the core of SAPLE: advanced search query interpretation and inexact string matching. SAPLE's query interpretation permits the user to perform compound queries when typing into a single search field; where able, SAPLE infers the type of field that the user intends to search on based on the value of the search term. SAPLE's inexact string matching feature yields a high-quality ranking of personnel search results even when there are no exact matches to the user's query. This paper explores these two key features, describing in detail the architecture and operation of SAPLE. Finally, an extensive analysis on logged search query data taken from an 11-week sample period is presented.

  2. Sampling Strategies and Processing of Biobank Tissue Samples from Porcine Biomedical Models.

    Science.gov (United States)

    Blutke, Andreas; Wanke, Rüdiger

    2018-03-06

    In translational medical research, porcine models have steadily become more popular. Considering the high value of individual animals, particularly of genetically modified pig models, and the often-limited number of available animals of these models, establishment of (biobank) collections of adequately processed tissue samples suited for a broad spectrum of subsequent analyses methods, including analyses not specified at the time point of sampling, represent meaningful approaches to take full advantage of the translational value of the model. With respect to the peculiarities of porcine anatomy, comprehensive guidelines have recently been established for standardized generation of representative, high-quality samples from different porcine organs and tissues. These guidelines are essential prerequisites for the reproducibility of results and their comparability between different studies and investigators. The recording of basic data, such as organ weights and volumes, the determination of the sampling locations and of the numbers of tissue samples to be generated, as well as their orientation, size, processing and trimming directions, are relevant factors determining the generalizability and usability of the specimen for molecular, qualitative, and quantitative morphological analyses. Here, an illustrative, practical, step-by-step demonstration of the most important techniques for generation of representative, multi-purpose biobank specimen from porcine tissues is presented. The methods described here include determination of organ/tissue volumes and densities, the application of a volume-weighted systematic random sampling procedure for parenchymal organs by point-counting, determination of the extent of tissue shrinkage related to histological embedding of samples, and generation of randomly oriented samples for quantitative stereological analyses, such as isotropic uniform random (IUR) sections generated by the "Orientator" and "Isector" methods, and vertical

  3. Status report on the Zagreb Radiocarbon Laboratory – AMS and LSC results of VIRI intercomparison samples

    International Nuclear Information System (INIS)

    Sironić, Andreja; Krajcar Bronić, Ines; Horvatinčić, Nada; Barešić, Jadranka; Obelić, Bogomil; Felja, Igor

    2013-01-01

    A new line for preparation of the graphite samples for 14 C dating by Accelerator Mass Spectrometry (AMS) in the Zagreb Radiocarbon Laboratory has been validated by preparing graphite from various materials distributed within the Fifth International Radiocarbon Intercomparison (VIRI) study. 14 C activity of prepared graphite was measured at the SUERC AMS facility. The results are statistically evaluated by means of the z-score and u-score values. The mean z-score value of 28 prepared VIRI samples is (0.06 ± 0.23) showing excellent agreement with the consensus VIRI values. Only one sample resulted in the u-score value above the limit of acceptability (defined for the confidence interval of 99%) and this was probably caused by a random contamination of the graphitization rig. After the rig had been moved to the new adapted and isolated room, all u-score values laid within the acceptable limits. Our LSC results of VIRI intercomparison samples are also presented and they are all accepted according to the u-score values.

  4. Results For The Third Quarter 2013 Tank 50 WAC Slurry Sample

    Energy Technology Data Exchange (ETDEWEB)

    Bannochie, Christopher J.

    2013-11-26

    This report details the chemical and radionuclide contaminant results for the characterization of the 2013 Third Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC) in effect at that time. Information from this characterization will be used by DWPF & Saltstone Facility Engineering (DSFE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System.

  5. Advancing the Use of Passive Sampling in Risk Assessment and Management of Sediments Contaminated with Hydrophobic Organic Chemicals: Results of an International Ex Situ Passive Sampling Interlaboratory Comparison.

    Science.gov (United States)

    Jonker, Michiel T O; van der Heijden, Stephan A; Adelman, Dave; Apell, Jennifer N; Burgess, Robert M; Choi, Yongju; Fernandez, Loretta A; Flavetta, Geanna M; Ghosh, Upal; Gschwend, Philip M; Hale, Sarah E; Jalalizadeh, Mehregan; Khairy, Mohammed; Lampi, Mark A; Lao, Wenjian; Lohmann, Rainer; Lydy, Michael J; Maruya, Keith A; Nutile, Samuel A; Oen, Amy M P; Rakowska, Magdalena I; Reible, Danny; Rusina, Tatsiana P; Smedes, Foppe; Wu, Yanwen

    2018-03-20

    This work presents the results of an international interlaboratory comparison on ex situ passive sampling in sediments. The main objectives were to map the state of the science in passively sampling sediments, identify sources of variability, provide recommendations and practical guidance for standardized passive sampling, and advance the use of passive sampling in regulatory decision making by increasing confidence in the use of the technique. The study was performed by a consortium of 11 laboratories and included experiments with 14 passive sampling formats on 3 sediments for 25 target chemicals (PAHs and PCBs). The resulting overall interlaboratory variability was large (a factor of ∼10), but standardization of methods halved this variability. The remaining variability was primarily due to factors not related to passive sampling itself, i.e., sediment heterogeneity and analytical chemistry. Excluding the latter source of variability, by performing all analyses in one laboratory, showed that passive sampling results can have a high precision and a very low intermethod variability (sampling, irrespective of the specific method used, is fit for implementation in risk assessment and management of contaminated sediments, provided that method setup and performance, as well as chemical analyses are quality-controlled.

  6. Protection of Location Privacy Based on Distributed Collaborative Recommendations.

    Science.gov (United States)

    Wang, Peng; Yang, Jing; Zhang, Jian-Pei

    2016-01-01

    In the existing centralized location services system structure, the server is easily attracted and be the communication bottleneck. It caused the disclosure of users' location. For this, we presented a new distributed collaborative recommendation strategy that is based on the distributed system. In this strategy, each node establishes profiles of their own location information. When requests for location services appear, the user can obtain the corresponding location services according to the recommendation of the neighboring users' location information profiles. If no suitable recommended location service results are obtained, then the user can send a service request to the server according to the construction of a k-anonymous data set with a centroid position of the neighbors. In this strategy, we designed a new model of distributed collaborative recommendation location service based on the users' location information profiles and used generalization and encryption to ensure the safety of the user's location information privacy. Finally, we used the real location data set to make theoretical and experimental analysis. And the results show that the strategy proposed in this paper is capable of reducing the frequency of access to the location server, providing better location services and protecting better the user's location privacy.

  7. Outpatient endometrial aspiration: an alternative to methotrexate for pregnancy of unknown location.

    Science.gov (United States)

    Insogna, Iris G; Farland, Leslie V; Missmer, Stacey A; Ginsburg, Elizabeth S; Brady, Paula C

    2017-08-01

    Pregnancies of unknown location with abnormal beta-human chorionic gonadotropin trends are frequently treated as presumed ectopic pregnancies with methotrexate. Preliminary data suggest that outpatient endometrial aspiration may be an effective tool to diagnose pregnancy location, while also sparing women exposure to methotrexate. The purpose of this study was to evaluate the utility of an endometrial sampling protocol for the diagnosis of pregnancies of unknown location after in vitro fertilization. A retrospective cohort study of 14,505 autologous fresh and frozen in vitro fertilization cycles from October 2007 to September 2015 was performed; 110 patients were diagnosed with pregnancy of unknown location, defined as a positive beta-human chorionic gonadotropin without ultrasound evidence of intrauterine or ectopic pregnancy and an abnormal beta-human chorionic gonadotropin trend (location, failed intrauterine pregnancy was diagnosed in 46 patients (42%), and ectopic pregnancy was diagnosed in 64 patients (58%). Clinical variables that included fresh or frozen embryo transfer, day of embryo transfer, serum beta-human chorionic gonadotropin at the time of sampling, endometrial thickness, and presence of an adnexal mass were not significantly different between patients with failed intrauterine pregnancy or ectopic pregnancy. In patients with failed intrauterine pregnancy, 100% demonstrated adequate postsampling beta-human chorionic gonadotropin declines; villi were identified in just 46% (n=21 patients). Patients with failed intrauterine pregnancy had significantly shorter time to resolution (negative serum beta-human chorionic gonadotropin) after sampling compared with patients with ectopic pregnancy (12.6 vs 26.3 days; Plocation are spared methotrexate, with a shorter time to pregnancy resolution than those who receive methotrexate. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Gamma radiation measurement in select sand samples from Camburi beach - Vitoria, Espirito Santo, Brazil: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Livia F.; Pecequilo, Brigitte R.S.; Aquino, Reginaldo R., E-mail: lfbarros@ipen.b, E-mail: brigitte@ipen.b, E-mail: raquino@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The variation of natural radioactivity along the surface of the beach sands of Camburi, located in Vitoria, capital of Espirito Santo, southeastern Brazil, was determined from the contents of {sup 226}Ra, {sup 232}Th and {sup 40}K. Eleven collecting points was selected along all the 6 km extension of the Camburi beach. Sand samples collected from all established points on January 2011 were dried and sealed in standard 100 mL polyethylene flasks and measured by high resolution gamma spectrometry after a 4 weeks ingrowth period, in order to allow the secular equilibrium in the {sup 238}U and {sup 232}Th series. The {sup 226}Ra concentration was determined from the weighted average concentrations of {sup 214}Pb and {sup 214}Bi. The {sup 232}Th concentration was determined from the weighted average concentrations of {sup 228}Ac, {sup 212}Pb and {sup 212}Bi and the {sup 40}K from its single gamma transition. Preliminary results show activity concentrations varying from 5 Bq.kg{sup -1} to {sup 222} Bq.kg{sup -1} for {sup 226}Ra and from 14 Bq.kg{sup -1} to 1074 Bq.kg{sup -'}1 for {sup 232}Th, both with the highest values for Camburi South and Central. For {sup 40}K, the activity concentrations ranged from 14 Bq.kg{sup -1} to 179 Bq.kg{sup -1} and the highest values were obtained for Camburi South. (author)

  9. Characterization Results for the January 2017 H-Tank Farm 2H Evaporator Overhead Sample

    Energy Technology Data Exchange (ETDEWEB)

    Truong, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Nicholson, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-04-11

    This report contains the radioanalytical results of the 2H evaporator overhead sample received at SRNL on January 19, 2017. Specifically, concentrations of 137Cs, 90Sr, and 129I are reported and compared to the corresponding Waste Acceptance Criteria (WAC) limits of the Effluent Treatment Project (ETP) Waste Water Collection Tank (WWCT) (rev. 6). All of the radionuclide concentrations in the sample were found to be in compliance with the ETP WAC limits.

  10. Summary of the results and interpretation of tritium and noble gas measurements on groundwater samples from the Perch Lake Basin Area

    International Nuclear Information System (INIS)

    Kotzer, T.G.

    1999-02-01

    Along the west-central margin of the Lower Perch Lake Basin, a limited number of groundwaters have been sampled from piezometers at depths of between 8 and 17 m and distances of between 100 and 900 m downgradient from their recharge location near Area A. Concentrations of tritium in these groundwaters varied between approximately 100 and 2800 TU. Measurements of dissolved gases in these groundwaters indicate concentrations of 4 He and neon approximating those in recently recharged groundwaters; however, the concentrations of 3 He are as much as 100 times higher, indicating the waters have accumulated tritiogenic 3 He. Using the 3 H/ 3 He dating technique, groundwater residence times on the order of 29 ± 8 years and groundwater velocities on the order of 0.1 m/day have been calculated for the flow system in the middle sand unit between Area A recharge and Perch Lake. These results, although based on a very small number of groundwater analyses, are comparable to earlier estimates of groundwater residence times and velocities obtained using Darcy calculations, borehole dilution experiments and tracer-test results from previous hydrogeologic studies in the area. (author)

  11. The economic impact of poor sample quality in clinical chemistry laboratories: results from a global survey.

    Science.gov (United States)

    Erdal, Erik P; Mitra, Debanjali; Khangulov, Victor S; Church, Stephen; Plokhoy, Elizabeth

    2017-03-01

    Background Despite advances in clinical chemistry testing, poor blood sample quality continues to impact laboratory operations and the quality of results. While previous studies have identified the preanalytical causes of lower sample quality, few studies have examined the economic impact of poor sample quality on the laboratory. Specifically, the costs associated with workarounds related to fibrin and gel contaminants remain largely unexplored. Methods A quantitative survey of clinical chemistry laboratory stakeholders across 10 international regions, including countries in North America, Europe and Oceania, was conducted to examine current blood sample testing practices, sample quality issues and practices to remediate poor sample quality. Survey data were used to estimate costs incurred by laboratories to mitigate sample quality issues. Results Responses from 164 participants were included in the analysis, which was focused on three specific issues: fibrin strands, fibrin masses and gel globules. Fibrin strands were the most commonly reported issue, with an overall incidence rate of ∼3%. Further, 65% of respondents indicated that these issues contribute to analyzer probe clogging, and the majority of laboratories had visual inspection and manual remediation practices in place to address fibrin- and gel-related quality problems (55% and 70%, respectively). Probe maintenance/replacement, visual inspection and manual remediation were estimated to carry significant costs for the laboratories surveyed. Annual cost associated with lower sample quality and remediation related to fibrin and/or gel globules for an average US laboratory was estimated to be $100,247. Conclusions Measures to improve blood sample quality present an important step towards improved laboratory operations.

  12. Storing and accessing radioactivity data in environmental samples: the resources of GEORAD

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Tadeu A. de A.; Gonzalez, Sergio de A.; Reis, Rocio G. dos; Vasconcellos, Luiza M. de H. e; Lauria, Dejanira de C., E-mail: tedsilva@ird.gov.br, E-mail: gonzalez@ird.gov.br, E-mail: rocio@ird.gov.br, E-mail: luiza@ird.gov.br, E-mail: dejanira@ird.gov.br [Isntituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-07-01

    A georeferenced information system of radioactivity in environmental samples, named GEORAD, was created with the goal of aggregating, storing and promoting the preservation of the data produced by Brazilian researches, and sharing with the research community a database on radioactivity in Brazil. The system provides information on concentrations of the natural series, cosmogenic and fall out radionuclides in samples of soil, water and food, among others, along with the geographical location of the samples. By this way, the location of the sample can be visualized on Brazilian map. A spreadsheet containing all the data and information about the sample can be also obtained. As a result, the database system can enable the available data to be exploited to the maximum potential for further research and allows new research on existing information. The system also provides reference information on where the data information were obtained, that enables data citation and linking data with publications to increase visibility and accessibility of data and the research itself. The GEORAD system has been continuously fed and updated, containing, currently, data from more than 2,000 samples. This paper presents the latest system updates and discusses its resources. (author)

  13. Storing and accessing radioactivity data in environmental samples: the resources of GEORAD

    International Nuclear Information System (INIS)

    Silva, Tadeu A. de A.; Gonzalez, Sergio de A.; Reis, Rocio G. dos; Vasconcellos, Luiza M. de H. e; Lauria, Dejanira de C.

    2013-01-01

    A georeferenced information system of radioactivity in environmental samples, named GEORAD, was created with the goal of aggregating, storing and promoting the preservation of the data produced by Brazilian researches, and sharing with the research community a database on radioactivity in Brazil. The system provides information on concentrations of the natural series, cosmogenic and fall out radionuclides in samples of soil, water and food, among others, along with the geographical location of the samples. By this way, the location of the sample can be visualized on Brazilian map. A spreadsheet containing all the data and information about the sample can be also obtained. As a result, the database system can enable the available data to be exploited to the maximum potential for further research and allows new research on existing information. The system also provides reference information on where the data information were obtained, that enables data citation and linking data with publications to increase visibility and accessibility of data and the research itself. The GEORAD system has been continuously fed and updated, containing, currently, data from more than 2,000 samples. This paper presents the latest system updates and discusses its resources. (author)

  14. Locating Depots for Capacitated Vehicle Routing

    DEFF Research Database (Denmark)

    Gørtz, Inge Li; Nagarajan, Viswanath

    2011-01-01

    that all demands are satisfied and the total cost is minimized. Our main result is a constant-factor approximation algorithm for k-LocVRP. To achieve this result, we reduce k-LocVRP to the following generalization of k median, which might be of independent interest. Given a metric (V, d), bound k...... median forest, which leads to a (12+E)-approximation algorithm for k-LocVRP, for any constant E > 0. The algorithm for k median forest is t-swap local search, and we prove that it has locality gap 3 + 2 t ; this generalizes the corresponding result for k median [3]. Finally we consider the k median......We study a location-routing problem in the context of capacitated vehicle routing. The input to k-LocVRP is a set of demand locations in a metric space and a fleet of k vehicles each of capacity Q. The objective is to locate k depots, one for each vehicle, and compute routes for the vehicles so...

  15. Discordance between location of positive cores in biopsy and location of positive surgical margin following radical prostatectomy.

    Science.gov (United States)

    Kim, Ji Won; Park, Hyoung Keun; Kim, Hyeong Gon; Ham, Dong Yeub; Paick, Sung Hyun; Lho, Yong Soo; Choi, Woo Suk

    2015-10-01

    We compared location of positive cores in biopsy and location of positive surgical margin (PSM) following radical prostatectomy. This retrospective analysis included patients who were diagnosed as prostate cancer by standard 12-core transrectal ultrasonography guided prostate biopsy, and who have PSM after radical prostatectomy. After exclusion of number of biopsy cores location data, 46 patients with PSM were identified. Locations of PSM in pathologic specimen were reported as 6 difference sites (apex, base and lateral in both sides). Discordance of biopsy result and PSM was defined when no positive cores in biopsy was identified at the location of PSM. Most common location of PSM were right apex (n=21) and left apex (n=15). Multiple PSM was reported in 21 specimens (45.7%). In 32 specimens (69.6%) with PSM, one or more concordant positive biopsy cores were identified, but 14 specimens (28%) had no concordant biopsy cores at PSM location. When discordant rate was separated by locations of PSM, right apex PSM had highest rate of discordant (38%). The discordant group had significantly lower prostate volume and lower number of positive cores in biopsy than concordant group. This study showed that one fourth of PSM occurred at location where tumor was not detected at biopsy and that apex PSM had highest rate of discordant. Careful dissection to avoid PSM should be performed in every location, including where tumor was not identified in biopsy.

  16. UMTRA project water sampling and analysis plan, Maybell, Colorado

    International Nuclear Information System (INIS)

    1994-06-01

    This water sampling and analysis plan (WSAP) describes planned water sampling activities and provides the regulatory and technical basis for ground water sampling in 1994 at the US Department of Energy's (DOE) Uranium Mill Tailings Remedial Action (UMTRA) Project site in Maybell, Colorado. The WSAP identifies and justifies sampling locations, analytical parameters, and sampling frequencies at the site. The ground water data will be used for site characterization and risk assessment. The regulatory basis for the ground water and surface water monitoring activities is derived from the EPA regulations in 40 CFR Part 192 (1993) and the proposed EPA standards of 1987 (52 FR 36000). Sampling procedures are guided by the UMTRA Project standard operating procedures (SOP) (JEG, n.d.), the Technical Approach Document (TAD) (DOE, 1989), and the most effective technical approach for the site. This WSAP also includes a summary and the results of water sampling activities from 1989 through 1992 (no sampling was performed in 1993)

  17. Sampling and analysis plan for sludge located in fuel storage canisters of the 105-K West basin

    International Nuclear Information System (INIS)

    Baker, R.B.

    1997-01-01

    This Sampling and Analysis Plan (SAP) provides direction for the first sampling of sludge from the K West Basin spent fuel canisters. The specially developed sampling equipment removes representative samples of sludge while maintaining the radioactive sample underwater in the basin pool (equipment is described in WHC-SD-SNF-SDD-004). Included are the basic background logic for sample selection, the overall laboratory analyses required and the laboratory reporting required. These are based on requirements put forth in the data quality objectives (WHC-SD-SNF-DQO-012) established for this sampling and characterization activity

  18. ANALYTICAL RESULTS OF MOX COLEMANITE CONCRETE SAMPLES POURED AUGUST 29, 2012

    Energy Technology Data Exchange (ETDEWEB)

    Best, D.; Cozzi, A.; Reigel, M.

    2012-12-20

    The Mixed Oxide Fuel Fabrication Facility (MFFF) will use colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory is tasked with measuring the total density, partial hydrogen density, and partial boron density of the colemanite concrete. Samples poured 8/29/12 were received on 9/20/2012 and analyzed. The average total density of each of the samples measured by the ASTM method C 642 was within the lower bound of 1.88 g/cm{sup 3}. The average partial hydrogen density of samples 8.6.1, 8.7.1, and 8.5.3 as measured using method ASTM E 1311 met the lower bound of 6.04E-02 g/cm{sup 3}. The average measured partial boron density of each sample met the lower bound of 1.65E-01 g/cm{sup 3} measured by the ASTM C 1301 method. The average partial hydrogen density of samples 8.5.1, 8.6.3, and 8.7.3 did not meet the lower bound. The samples, as received, were not wrapped in a moist towel as previous samples and appeared to be somewhat drier. This may explain the lower hydrogen partial density with respect to previous samples.

  19. Maxillary Four Implant-retained Overdentures via Locator® Attachment: Intermediate-term Results from a Retrospective Study.

    Science.gov (United States)

    Wang, Feng; Monje, Alberto; Huang, Wei; Zhang, Zhiyong; Wang, Guomin; Wu, Yiqun

    2016-06-01

    Maxillary overdentures have been utilized to restore oral function in scenarios where limited bone structure represents a drawback for financial issues and for cases where oral hygiene is uncertain. The aim of this study was to evaluate the intermediate-term clinical outcome of four locator attachment retaining maxillary overdentures and to test their reliability. A retrospective study was conducted from January 2007 to October 2013. After the placement of four maxillary dental implants and a healing period of approximately 3 months, all the implants were restored with locator-retained overdentures with partial palatal coverage. Subjects and implant characteristics, implant position (anterior vs posterior maxilla), bone quality, and opposing dentition were recorded. Peri-implant clinical parameters and marginal bone loss (MBL) were evaluated after delivery of the final prosthesis and annually thereafter. The performance of locator components and the prosthetic restoration were also recorded at follow-up. A total of 104 implants were placed in 26 subjects (11 women, 15 men; mean age, 64 years; age range, 55-76 years). One implant failed before loading. One subject dropped out of the study during a mean follow-up period of 46 months (range: 7-73 months), achieving an overall survival rate of 95.2%. Clinical parameters revealed healthy tissues around most of the implants, with low scores of plaque and bleeding indices. At the last follow-up evaluation, the mean MBL was 1.7 ± 1.1 mm (0.4-2.6 mm). Regression model analysis indicated that MBL for implants in the posterior maxilla was significantly higher than that for implants in the anterior maxilla (p = .0487). Overall, 26 technical and prosthetic complications were reported. Within the limitations of this study, maxillary four implant-retained overdentures via Locator attachment seem to be a predictable alternative for oral rehabilitation. © 2015 Wiley Periodicals, Inc.

  20. The Essentials of Parathyroid Hormone Venous Sampling

    Energy Technology Data Exchange (ETDEWEB)

    Taslakian, Bedros, E-mail: btaslakian@gmail.com [NYU Langone Medical Center, Department of Radiology, NYU School of Medicine (United States); Trerotola, Scott O., E-mail: streroto@uphs.upenn.edu [Perelman School of Medicine of the University of Pennsylvania, Department of Radiology (United States); Sacks, Barry, E-mail: bsacks@bidmc.harvard.edu [Beth Israel Deaconess Medical Center, Department of Interventional Radiology (United States); Oklu, Rahmi, E-mail: oklu.rahmi@mayo.edu [Mayo Clinic, Department of Interventional Radiology (United States); Deipolyi, Amy, E-mail: deipolya@mskcc.org [Memorial Sloan Kettering Cancer Center, Department of Radiology (United States)

    2017-01-15

    Hyperparathyroidism is an excess of parathyroid hormone in the blood due to over-activity of one or more parathyroid gland. Localization of abnormal glands with noninvasive imaging modalities, such as technetium sestamibi scan and cross-sectional imaging, has a high success rate. Parathyroid venous sampling is performed for patients with persistent or recurrent disease after previous parathyroid surgery, when repeat noninvasive imaging studies are negative or discordant. The success of invasive localization studies and results interpretation is dependent on the interventional radiologist’s understanding of the normal and ectopic anatomic locations of parathyroid glands, as well as their blood supply and venous drainage. Anatomic and technical considerations for selective parathyroid venous sampling are reviewed.

  1. Protein (multi-)location prediction: utilizing interdependencies via a generative model.

    Science.gov (United States)

    Simha, Ramanuja; Briesemeister, Sebastian; Kohlbacher, Oliver; Shatkay, Hagit

    2015-06-15

    Proteins are responsible for a multitude of vital tasks in all living organisms. Given that a protein's function and role are strongly related to its subcellular location, protein location prediction is an important research area. While proteins move from one location to another and can localize to multiple locations, most existing location prediction systems assign only a single location per protein. A few recent systems attempt to predict multiple locations for proteins, however, their performance leaves much room for improvement. Moreover, such systems do not capture dependencies among locations and usually consider locations as independent. We hypothesize that a multi-location predictor that captures location inter-dependencies can improve location predictions for proteins. We introduce a probabilistic generative model for protein localization, and develop a system based on it-which we call MDLoc-that utilizes inter-dependencies among locations to predict multiple locations for proteins. The model captures location inter-dependencies using Bayesian networks and represents dependency between features and locations using a mixture model. We use iterative processes for learning model parameters and for estimating protein locations. We evaluate our classifier MDLoc, on a dataset of single- and multi-localized proteins derived from the DBMLoc dataset, which is the most comprehensive protein multi-localization dataset currently available. Our results, obtained by using MDLoc, significantly improve upon results obtained by an initial simpler classifier, as well as on results reported by other top systems. MDLoc is available at: http://www.eecis.udel.edu/∼compbio/mdloc. © The Author 2015. Published by Oxford University Press.

  2. Lost in Location

    DEFF Research Database (Denmark)

    Hansen, Lone Koefoed

    2009-01-01

    traversed. While becoming destination aware, the individual loses her location awareness. The article proposes that the reason people get lost when using sat-nav is due to a wrong location-performative paradigm. As an alternative, the article introduces and analyzes two performance-related examples...... that illustrate an alternative location-performative paradigm: Meredith Warner's Lost/Found knitting series and Etter and Schecht's Melodious Walkabout. In both examples, the artist's hand becomes the intermediary between alien and location. Thus, by exploring how wayfinding can be a poetically situated...... performance, the article examines how the growing locative media industry can learn from the location-aware performative strategies employed by artists who create situated and urban performances for the curious participant. The academic frames employed in the analysis draw on psychogeography, site...

  3. Quarterly sampling of the wetlands along the old F-Area effluent ditch: August 1994. Revision 1

    International Nuclear Information System (INIS)

    Cummins, C.L.; Dixon, K.L.

    1994-08-01

    In August 1994, well point water and near-surface water samples were collected to further characterize tritium and volatile organic compounds in the Wetlands along the old F-Area effluent ditch south of 643-E at the Savannah River Plant. Well point samples were collected from seven locations and near-surface water samples were collected at four locations. Results of the August 1994 sampling event further support findings that tritium and volatile organic compounds are outcropping in the Wetlands near the old F-area effluent ditch. Four analytes (1,2-dichloroethylene, trichloroethylene, tritium, and vinyl chloride) were detected at least once at concentrations above the primary Drinking Water Standards or the Maximum Contaminant Levels. Five analytes (the above chemicals plus tetrachloroethylene) were detected at least once in the near-surface water samples at concentrations greater than the method detection limit

  4. 40 CFR 761.298 - Decisions based on PCB concentration measurements resulting from sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Decisions based on PCB concentration... Cleanup and On-Site Disposal of Bulk PCB Remediation Waste and Porous Surfaces in Accordance With § 761.61(a)(6) § 761.298 Decisions based on PCB concentration measurements resulting from sampling. (a) For...

  5. Gender, Location and Rural-Urban Differences in the Goal ...

    African Journals Online (AJOL)

    The need to identify critical factors necessary to improve the mandate attainment of the National Youth Service Corps (NYSC) Scheme informed this study on gender, location and rural-urban differences in the goal attainment of NYSC in South West Nigeria. Using a multistage sampling procedure, 120 outgoing youth corps ...

  6. Medical specialists' choice of location: the role of geographical attachment in Norway.

    Science.gov (United States)

    Kristiansen, I S; Førde, O H

    1992-01-01

    The relation between current place of work (area of the country) and factors that might possibly represent doctors geographical attachments was studied in a sample of 322 Norwegian medical specialists. Location of hospital residency, age and geographical origin of spouse were associated with current location. Geographical attachment seems to influence doctors' locational choices from start of medical school until the end of their residency. The probability that a doctor shall locate in peripheral areas may increase from less than 10% to more than 50% if the doctor has the residency training in the periphery. Hence, favoring entrance to medical schools of students from the underserved areas, and location of graduate and postgraduate medical training in the underserved areas, as far as it is feasible while still maintaining medical standards, is suggested by the study.

  7. Locating the origins of blue and white porcelains using EDXRF

    International Nuclear Information System (INIS)

    Yu, K.N.; Miao, J.M.

    1997-01-01

    Among the main sites of production of ancient Chinese blue and white porcelains can be included Jingdezhen in Jiangxi Province, the Yuxi and Jianshui Kilns of Yunnan Province and the Pinghe Kiln of Fujian Province. The current work focuses on an elemental characterization of ancient porcelains according to the location of manufacture, also incorporating a similar study of the blue and white porcelains of the Qing dynasty from Wun Yiu in Hong Kong, and modern blue and white porcelains from Germany, Japan and Thailand. Non-destructive analysis of samples of porcelain using energy dispersive X-ray fluorescence (EDXRF) has yielded results in terms of 13 chemical elements, namely, Ti, Mn, Fe, Co, Ni, Cu, Zn, Ga, Pb, Rb, Sr, Y and Zr. Principal component analysis has been performed on the data, allowing representation of the first, second and third principal components of the data in 3 D scatter plots; the results reveal data clusterings which correlate to a high degree with the known sites of origin. The conclusion is that the present method is capable of determining differences in elemental concentrations of blue and white porcelains, and that these differences can be used to locate the originating site of manufacture. (Author)

  8. Locating the origins of blue and white porcelains using EDXRF

    Energy Technology Data Exchange (ETDEWEB)

    Yu, K.N. [City Univ., Hong Kong (Hong Kong). Dept. of Physics and Materials Science; Miao, J.M. [Palace Museum, Beijing (China). Dept. of Science and Technology

    1997-07-30

    Among the main sites of production of ancient Chinese blue and white porcelains can be included Jingdezhen in Jiangxi Province, the Yuxi and Jianshui Kilns of Yunnan Province and the Pinghe Kiln of Fujian Province. The current work focuses on an elemental characterization of ancient porcelains according to the location of manufacture, also incorporating a similar study of the blue and white porcelains of the Qing dynasty from Wun Yiu in Hong Kong, and modern blue and white porcelains from Germany, Japan and Thailand. Non-destructive analysis of samples of porcelain using energy dispersive X-ray fluorescence (EDXRF) has yielded results in terms of 13 chemical elements, namely, Ti, Mn, Fe, Co, Ni, Cu, Zn, Ga, Pb, Rb, Sr, Y and Zr. Principal component analysis has been performed on the data, allowing representation of the first, second and third principal components of the data in 3 D scatter plots; the results reveal data clusterings which correlate to a high degree with the known sites of origin. The conclusion is that the present method is capable of determining differences in elemental concentrations of blue and white porcelains, and that these differences can be used to locate the originating site of manufacture. (Author).

  9. Hanford site environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1998-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1 open-quotes General Environmental Protection Program,close quotes and DOE Order 5400.5, open-quotes Radiation Protection of the Public and the Environment.close quotes The sampling methods are described in the Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office, DOE/RL91-50, Rev. 2, U.S. Department of Energy, Richland, Washington. This document contains the 1998 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section of this document describes the planned sampling schedule for a specific media (air, surface water, biota, soil and vegetation, sediment, and external radiation). Each section includes the sample location, sample type, and analyses to be performed on the sample. In some cases, samples are scheduled on a rotating basis and may not be planned for 1998 in which case the anticipated year for collection is provided. In addition, a map is included for each media showing sample locations

  10. Predictors of locating women six to eight years after contact: internet resources at recruitment may help to improve response rates in longitudinal research

    Directory of Open Access Journals (Sweden)

    Gignac Monique AM

    2007-06-01

    Full Text Available Abstract Background The ability to locate those sampled has important implications for response rates and thus the success of survey research. The purpose of this study was to examine predictors of locating women requiring tracing using publicly available methods (primarily Internet searches, and to determine the additional benefit of vital statistics linkages. Methods Random samples of women aged 65–89 years residing in two regions of Ontario, Canada were selected from a list of those who completed a questionnaire between 1995 and 1997 (n = 1,500. A random sample of 507 of these women had been searched on the Internet as part of a feasibility pilot in 2001. All 1,500 women sampled were mailed a newsletter and information letter prior to recruitment by telephone in 2003 and 2004. Those with returned mail or incorrect telephone number(s required tracing. Predictors of locating women were examined using logistic regression. Results Tracing was required for 372 (25% of the women sampled, and of these, 181 (49% were located. Predictors of locating women were: younger age, residing in less densely populated areas, having had a web-search completed in 2001, and listed name identified on the Internet prior to recruitment in 2003. Although vital statistics linkages to death records subsequently identified 41 subjects, these data were incomplete. Conclusion Prospective studies may benefit from using Internet resources at recruitment to determine the listed names for telephone numbers thereby facilitating follow-up tracing and improving response rates. Although vital statistics linkages may help to identify deceased individuals, these may be best suited for post hoc response rate adjustment.

  11. Quarter Dates Location(s) Purpose Transportation and Travel ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    IDRC CRDI

    Dates. Location(s). Purpose. Transportation and Travel. Accommodation,. Meals and Other. Hospitality. Total. Expenses. Quarter 1. May 15. Ottawa, ON. Meetings. May 20 to 21. Washington DC. Conference. 11,364.93. 3,274.71. 53.50. 14,693.14. May 5 to June 5. Kenya and England. Meetings. June 18 to 21. Winnipeg, MB.

  12. i-Locate - Indoor/Outdoor location and Asset Management through Open Data

    Directory of Open Access Journals (Sweden)

    Claudio Eccher

    2015-02-01

    Full Text Available Studi recenti hanno evidenziato che, in media, trascorriamo circa il 90% del nostro tempo in ambienti chiusi e, spesso, non familiari. L’esigenza di localizzare/guidare persone o ogg etti in spazi sia esterni che interni (senza discontinuità tra esterno ed interno darà origine ad una serie di nuovi servizi di tipo LBS (Location-Based Services che potranno avere anche una notevole rilevanza economica. i-locate (Indoor / outdoor location and Asset Management Through open geodata is a project that aims to develop a set of tools and services based on geo location technologies based on open data for the location and management of objects in indoor and outdoor spaces. The tools are intended both to citizens who use their smartphones to access services, aids to navigation from the front door to internal destinations to buildings (public office, clinic, shop, etc.. Obtaining any information available to support (code , unforeseen changes in the path, suggestions, etc., and professionals for specific activities that require the location of people, equipment, etc. i-locate to an intense use of GIS technologies for navigation and tracking "indoor" (indoor GIS, 3D GIS, to locate people (eg. Alzheimer's patients and their movements in areas not suited (geofencing to identify and track objects / portable equipment for their location, management and maintenance.

  13. i-Locate - Indoor/Outdoor location and Asset Management through Open Data

    Directory of Open Access Journals (Sweden)

    Claudio Eccher

    2015-02-01

    Full Text Available Studi recenti hanno evidenziato che, in media, trascorriamo circa il 90% del nostro tempo in ambienti chiusi e, spesso, non familiari. L’esigenza di localizzare/guidare persone o ogg etti in spazi sia esterni che interni (senza discontinuità tra esterno ed interno darà origine ad una serie di nuovi servizi di tipo LBS (Location-Based Services che potranno avere anche una notevole rilevanza economica.i-locate (Indoor / outdoor location and Asset Management Through open geodata is a project that aims to develop a set of tools and services based on geo location technologies based on open data for the location and management of objects in indoor and outdoor spaces. The tools are intended both to citizens who use their smartphones to access services, aids to navigation from the front door to internal destinations to buildings (public office, clinic, shop, etc.. Obtaining any information available to support (code , unforeseen changes in the path, suggestions, etc., and professionals for specific activities that require the location of people, equipment, etc. i-locate to an intense use of GIS technologies for navigation and tracking "indoor" (indoor GIS, 3D GIS, to locate people (eg. Alzheimer's patients and their movements in areas not suited (geofencing to identify and track objects / portable equipment for their location, management and maintenance.

  14. Resolution optimization with irregularly sampled Fourier data

    International Nuclear Information System (INIS)

    Ferrara, Matthew; Parker, Jason T; Cheney, Margaret

    2013-01-01

    Image acquisition systems such as synthetic aperture radar (SAR) and magnetic resonance imaging often measure irregularly spaced Fourier samples of the desired image. In this paper we show the relationship between sample locations, their associated backprojection weights, and image resolution as characterized by the resulting point spread function (PSF). Two new methods for computing data weights, based on different optimization criteria, are proposed. The first method, which solves a maximal-eigenvector problem, optimizes a PSF-derived resolution metric which is shown to be equivalent to the volume of the Cramer–Rao (positional) error ellipsoid in the uniform-weight case. The second approach utilizes as its performance metric the Frobenius error between the PSF operator and the ideal delta function, and is an extension of a previously reported algorithm. Our proposed extension appropriately regularizes the weight estimates in the presence of noisy data and eliminates the superfluous issue of image discretization in the choice of data weights. The Frobenius-error approach results in a Tikhonov-regularized inverse problem whose Tikhonov weights are dependent on the locations of the Fourier data as well as the noise variance. The two new methods are compared against several state-of-the-art weighting strategies for synthetic multistatic point-scatterer data, as well as an ‘interrupted SAR’ dataset representative of in-band interference commonly encountered in very high frequency radar applications. (paper)

  15. 30 CFR 75.336 - Sampling and monitoring requirements.

    Science.gov (United States)

    2010-07-01

    ... concentration of other sampling locations in the sealed area and other required information. Before miners... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Sampling and monitoring requirements. 75.336... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.336 Sampling and...

  16. Environmental monitoring at the nuclear power plants and Studsvik 1994. Results from measurements of radionuclide concentrations in environmental samples; Omgivningskontroll vid kaernkraftverken och Studsvik 1994. Resultat fraan maetningar av radionuklidhalter i miljoeprover

    Energy Technology Data Exchange (ETDEWEB)

    Bengtson, P.; Larsson, C.M.; Luening, M.

    1996-04-01

    As expected, marine samples from the vicinity of the power plants show detectable radionuclide concentrations, caused by the discharges from the plants. Very low concentrations are noted in the terrestrial samples. At several locations, the effects of the Chernobyl disaster still dominate. 12 refs, tabs.

  17. New sample carrier systems for thermogravimetric analysis under forced flow conditions and their influence on microkinetic results.

    Science.gov (United States)

    Seibel, C; Fieback, T M

    2015-09-01

    For thermogravimetric analysis, it has been shown that, depending on the type of sample container, different kinetic results could be obtained despite regarding the same reaction under constant conditions. This is due to limiting macrokinetic effects which are strongly dependant on the type of sample carrying system. This prompted the need for sample containers which deliver results minimally limited by diffusive mass transport. In this way, two container systems were developed, both characterized by a forced flow stream through a solid, porous bed: one from bottom to top (counter-current flow) and one from top to bottom (co-current flow). Optical test measurements were performed, the results indicating that reaction proceedings are almost fully independent of the geometrical shape of the sample containers. The Boudouard reaction was investigated with a standard crucible and the new developed systems; the reaction rates determined differed significantly, up to a factor of 6.2 at 1373 K.

  18. Natural Radioactivity Pattern of Surabaya Water Environmental Samples

    International Nuclear Information System (INIS)

    Rosidi; Agus Taftazani

    2007-01-01

    The gross β radioactivity and natural radionuclide of Surabaya environmental samples pattern have been evaluated. The environmental samples were chosen randomly at 12 locations. The environment samples were water (fresh, estuary and coastal), sediment, eichhornia crassipes (Mart) Solms, Mangrove (Rhizophora stylosa), (Moolgarda delicatus) fish and (Johnius (Johnieops) borneensis) (Sharpnose hammer croaker) fish. The water sample was evaporated; the sediment sample was dried and ground; the biotic samples was burnt at the temperature 500 °C ; The gross β measurement using GM detector and the radionuclides has been identified by γ spectrometer. From the investigation results could be concluded that the natural radioactivity of environmental samples was very low. gross-β of water samples were lower than the threshold value of local government regulation of Surabaya no: 2 year 2004 (1 Bq/L). The distribution of gross-β activity of eichhornia crassipes (Mart) Solms was higher than the other biotic, water and sediment samples as well as the accumulation of radionuclides in the water organism was taken place. The result of identification using γ spectrometer has detected 7 of radionuclides, i.e 210 Pb, 212 Pb, 214 Pb, 208 Tl, 214 Bi, 228 Ac, and 40 K in all sample. The distribution factor of sediment F D was less than bioaccumulation factor of biotic F B and it indicates that there the radionuclide accumulation migration follows the pattern of water - sediment - biotic sample. (author)

  19. 40 CFR 761.316 - Interpreting PCB concentration measurements resulting from this sampling scheme.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Interpreting PCB concentration... § 761.79(b)(3) § 761.316 Interpreting PCB concentration measurements resulting from this sampling... composite is 20 µg/100 cm2, then the entire 9.5 square meters has a PCB surface concentration of 20 µg/100...

  20. Headspace vapor characterization of Hanford waste Tank 241-BX-110: Results from samples collected on 04/30/96

    International Nuclear Information System (INIS)

    Evans, J.C.; Pool, K.H.; Thomas, B.L.; Olsen, K.B.; Fruchter, J.S.; Silvers, K.L.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-BX-110 (Tank BX-110) at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, sample volumes provided by WHC. A summary of the inorganic analytes, permanent gases, and total non-methane organic compounds is listed in a table. The three highest concentration analytes detected in SUMMA trademark canister and triple sorbent trap samples are also listed in the table. Detailed descriptions of the analytical results appear in the appendices

  1. Location Systems An Introduction to the Technology Behind Location Awareness

    CERN Document Server

    LaMarca, Anthony

    2008-01-01

    Advances in electronic location technology and the coming of age of mobile computing have opened the door for location-aware applications to permeate all aspects of everyday life. Location is at the core of a large number of high-value applications ranging from the life-and-death context of emergency response to serendipitous social meet-ups. For example, the market for GPS products and services alone is expected to grow to US200 billion by 2015. Unfortunately, there is no single location technology that is good for every situation and exhibits high accuracy, low cost, and universal coverage.

  2. Reliability of environmental sampling culture results using the negative binomial intraclass correlation coefficient.

    Science.gov (United States)

    Aly, Sharif S; Zhao, Jianyang; Li, Ben; Jiang, Jiming

    2014-01-01

    The Intraclass Correlation Coefficient (ICC) is commonly used to estimate the similarity between quantitative measures obtained from different sources. Overdispersed data is traditionally transformed so that linear mixed model (LMM) based ICC can be estimated. A common transformation used is the natural logarithm. The reliability of environmental sampling of fecal slurry on freestall pens has been estimated for Mycobacterium avium subsp. paratuberculosis using the natural logarithm transformed culture results. Recently, the negative binomial ICC was defined based on a generalized linear mixed model for negative binomial distributed data. The current study reports on the negative binomial ICC estimate which includes fixed effects using culture results of environmental samples. Simulations using a wide variety of inputs and negative binomial distribution parameters (r; p) showed better performance of the new negative binomial ICC compared to the ICC based on LMM even when negative binomial data was logarithm, and square root transformed. A second comparison that targeted a wider range of ICC values showed that the mean of estimated ICC closely approximated the true ICC.

  3. Location of New Firms

    DEFF Research Database (Denmark)

    Backman, Mikaela; Karlsson, Charlie

    2017-01-01

    characteristics, such as the commuting experience. Our results show that commuting influences the firm location choice. The probability of establishing a firm in the work municipality increases if the entrepreneur is a commuter, holding constant the type of region and unobservable and observable individual...

  4. Geospatial techniques for developing a sampling frame of watersheds across a region

    Science.gov (United States)

    Gresswell, Robert E.; Bateman, Douglas S.; Lienkaemper, George; Guy, T.J.

    2004-01-01

    Current land-management decisions that affect the persistence of native salmonids are often influenced by studies of individual sites that are selected based on judgment and convenience. Although this approach is useful for some purposes, extrapolating results to areas that were not sampled is statistically inappropriate because the sampling design is usually biased. Therefore, in recent investigations of coastal cutthroat trout (Oncorhynchus clarki clarki) located above natural barriers to anadromous salmonids, we used a methodology for extending the statistical scope of inference. The purpose of this paper is to apply geospatial tools to identify a population of watersheds and develop a probability-based sampling design for coastal cutthroat trout in western Oregon, USA. The population of mid-size watersheds (500-5800 ha) west of the Cascade Range divide was derived from watershed delineations based on digital elevation models. Because a database with locations of isolated populations of coastal cutthroat trout did not exist, a sampling frame of isolated watersheds containing cutthroat trout had to be developed. After the sampling frame of watersheds was established, isolated watersheds with coastal cutthroat trout were stratified by ecoregion and erosion potential based on dominant bedrock lithology (i.e., sedimentary and igneous). A stratified random sample of 60 watersheds was selected with proportional allocation in each stratum. By comparing watershed drainage areas of streams in the general population to those in the sampling frame and the resulting sample (n = 60), we were able to evaluate the how representative the subset of watersheds was in relation to the population of watersheds. Geospatial tools provided a relatively inexpensive means to generate the information necessary to develop a statistically robust, probability-based sampling design.

  5. Tank 241-U-104 headspace gas and vapor characterization results from samples collected on July 16, 1996

    International Nuclear Information System (INIS)

    Pool, K.H.; Evans, J.C.; Hayes, J.C.; Mitroshkov, A.V.; Edwards, J.A.; Julya, J.L.; Thornton, B.M.; Fruchter, J.S.; Silvers, K.L.

    1997-08-01

    This report presents the results from analyses of samples taken from the headspace of waste storage tank 241-U-104 (Tank U-104) at the Hanford Site in Washington State. Tank headspace samples collected by Westinghouse Hanford Company (WHC) were analyzed by Pacific Northwest National Laboratory (PNNL) to determine headspace concentrations of selected non-radioactive analytes. Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Vapor concentrations from sorbent trap samples are based on measured sample volumes provided by WHC. No analytes were determined to be above the immediate notification limits specified by the sampling and analysis plan. None of the flammable constituents were present at concentrations above the analytical instrument detection limits. Total headspace flammability was estimated to be <0.108% of the lower flammability limit. Average measured concentrations of targeted gases, inorganic vapors, and selected organic vapors are provided in a table. A summary of experimental methods, including sampling methodology, analytical procedures, and quality assurance and control methods are presented in Section 2.0. Detailed descriptions of the analytical results are provided in Section 3.0

  6. Tissue Sampling Guides for Porcine Biomedical Models.

    Science.gov (United States)

    Albl, Barbara; Haesner, Serena; Braun-Reichhart, Christina; Streckel, Elisabeth; Renner, Simone; Seeliger, Frank; Wolf, Eckhard; Wanke, Rüdiger; Blutke, Andreas

    2016-04-01

    This article provides guidelines for organ and tissue sampling adapted to porcine animal models in translational medical research. Detailed protocols for the determination of sampling locations and numbers as well as recommendations on the orientation, size, and trimming direction of samples from ∼50 different porcine organs and tissues are provided in the Supplementary Material. The proposed sampling protocols include the generation of samples suitable for subsequent qualitative and quantitative analyses, including cryohistology, paraffin, and plastic histology; immunohistochemistry;in situhybridization; electron microscopy; and quantitative stereology as well as molecular analyses of DNA, RNA, proteins, metabolites, and electrolytes. With regard to the planned extent of sampling efforts, time, and personnel expenses, and dependent upon the scheduled analyses, different protocols are provided. These protocols are adjusted for (I) routine screenings, as used in general toxicity studies or in analyses of gene expression patterns or histopathological organ alterations, (II) advanced analyses of single organs/tissues, and (III) large-scale sampling procedures to be applied in biobank projects. Providing a robust reference for studies of porcine models, the described protocols will ensure the efficiency of sampling, the systematic recovery of high-quality samples representing the entire organ or tissue as well as the intra-/interstudy comparability and reproducibility of results. © The Author(s) 2016.

  7. Headspace vapor characterization of Hanford waste tank 241-U-108: Results from samples collected on 8/29/95

    International Nuclear Information System (INIS)

    Thomas, B.L.; Clauss, T.W.; Evans, J.C.; McVeety, B.D.; Pool, K.H.; Olsten, K.B.; Fruchter, J.S.; Ligotke, M.W.

    1996-05-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-U-108 (Tank U-108) at the Hanford Site in Washington State. The results described in the report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest National Laboratory (PNNL). Analyte concentrations were based on analytical results and, where appropriate, sample volumes provided by WHC

  8. Phase 1 sampling and analysis plan for the 304 Concretion Facility closure activities

    International Nuclear Information System (INIS)

    Adler, J.G.

    1994-01-01

    This document provides guidance for the initial (Phase 1) sampling and analysis activities associated with the proposed Resource Conservation and Recovery Act of 1976 (RCRA) clean closure of the 304 Concretion Facility. Over its service life, the 304 Concretion Facility housed the pilot plants associated with cladding uranium cores, was used to store engineering equipment and product chemicals, was used to treat low-level radioactive mixed waste, recyclable scrap uranium generated during nuclear fuel fabrication, and uranium-titanium alloy chips, and was used for the repackaging of spent halogenated solvents from the nuclear fuels manufacturing process. The strategy for clean closure of the 304 Concretion Facility is to decontaminate, sample (Phase 1 sampling), and evaluate results. If the evaluation indicates that a limited area requires additional decontamination for clean closure, the limited area will be decontaminated, resampled (Phase 2 sampling), and the result evaluated. If the evaluation indicates that the constituents of concern are below action levels, the facility will be clean closed. Or, if the evaluation indicates that the constituents of concern are present above action levels, the condition of the facility will be evaluated and appropriate action taken. There are a total of 37 sampling locations comprising 12 concrete core, 1 concrete chip, 9 soil, 11 wipe, and 4 asphalt core sampling locations. Analysis for inorganics and volatile organics will be performed on the concrete core and soil samples. Separate concrete core samples will be required for the inorganic and volatile organic analysis (VOA). Analysis for inorganics only will be performed on the concrete chip, wipe, and asphalt samples

  9. Problematic Social Media Use: Results from a Large-Scale Nationally Representative Adolescent Sample.

    Science.gov (United States)

    Bányai, Fanni; Zsila, Ágnes; Király, Orsolya; Maraz, Aniko; Elekes, Zsuzsanna; Griffiths, Mark D; Andreassen, Cecilie Schou; Demetrovics, Zsolt

    2017-01-01

    Despite social media use being one of the most popular activities among adolescents, prevalence estimates among teenage samples of social media (problematic) use are lacking in the field. The present study surveyed a nationally representative Hungarian sample comprising 5,961 adolescents as part of the European School Survey Project on Alcohol and Other Drugs (ESPAD). Using the Bergen Social Media Addiction Scale (BSMAS) and based on latent profile analysis, 4.5% of the adolescents belonged to the at-risk group, and reported low self-esteem, high level of depression symptoms, and elevated social media use. Results also demonstrated that BSMAS has appropriate psychometric properties. It is concluded that adolescents at-risk of problematic social media use should be targeted by school-based prevention and intervention programs.

  10. A Proposal of New Spherical Particle Modeling Method Based on Stochastic Sampling of Particle Locations in Monte Carlo Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Song Hyun; Kim, Do Hyun; Kim, Jong Kyung [Hanyang Univ., Seoul (Korea, Republic of); Noh, Jea Man [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    To the high computational efficiency and user convenience, the implicit method had received attention; however, it is noted that the implicit method in the previous studies has low accuracy at high packing fraction. In this study, a new implicit method, which can be used at any packing fraction with high accuracy, is proposed. In this study, the implicit modeling method in the spherical particle distributed medium for using the MC simulation is proposed. A new concept in the spherical particle sampling was developed to solve the problems in the previous implicit methods. The sampling method was verified by simulating the sampling method in the infinite and finite medium. The results show that the particle implicit modeling with the proposed method was accurately performed in all packing fraction boundaries. It is expected that the proposed method can be efficiently utilized for the spherical particle distributed mediums, which are the fusion reactor blanket, VHTR reactors, and shielding analysis.

  11. A sampling strategy for estimating plot average annual fluxes of chemical elements from forest soils

    NARCIS (Netherlands)

    Brus, D.J.; Gruijter, de J.J.; Vries, de W.

    2010-01-01

    A sampling strategy for estimating spatially averaged annual element leaching fluxes from forest soils is presented and tested in three Dutch forest monitoring plots. In this method sampling locations and times (days) are selected by probability sampling. Sampling locations were selected by

  12. A Multi-Sample Cs-Sputter Negative Ion Source

    International Nuclear Information System (INIS)

    Alton, G.D.; Ball, J.A.; Bao, Y.; Cui, B.; Reed, C.A.; Williams, C.

    1998-01-01

    A multi-sample Cs sputter negative-ion source, equipped with a conical-geometry, W-surface-ionizer has been designed and fabricated that permits sample changes without disruption of on-line accelerator operation. Sample changing is effected by actuating an electro-pneumatic control system located at ground potential that drives an air-motor-driven sample-indexing-system mounted at high voltage; this arrangement avoids complications associated with indexing mechanisms that rely on electronic power-supplies located at high potential. In-beam targets are identified by LED indicator lights derived from a fiber-optic, Gray-code target-position sensor. Aspects of the overall source design and details of the indexing mechanism along with operational parameters, ion optics. intensities, and typical emittances for a variety of negative-ion species will be presented in this report

  13. A Multi-Sample Cs-Sputter Negative Ion Source

    Energy Technology Data Exchange (ETDEWEB)

    Alton, G.D.; Ball, J.A.; Bao, Y.; Cui, B.; Reed, C.A.; Williams, C.

    1998-10-05

    A multi-sample Cs sputter negative-ion source, equipped with a conical-geometry, W-surface-ionizer has been designed and fabricated that permits sample changes without disruption of on-line accelerator operation. Sample changing is effected by actuating an electro-pneumatic control system located at ground potential that drives an air-motor-driven sample-indexing-system mounted at high voltage; this arrangement avoids complications associated with indexing mechanisms that rely on electronic power-supplies located at high potential. In-beam targets are identified by LED indicator lights derived from a fiber-optic, Gray-code target-position sensor. Aspects of the overall source design and details of the indexing mechanism along with operational parameters, ion optics. intensities, and typical emittances for a variety of negative-ion species will be presented in this report.

  14. Reliability in the Location of Hindlimb Motor Representations in Fischer-344 Rats

    Science.gov (United States)

    Frost, Shawn B.; Iliakova, Maria; Dunham, Caleb; Barbay, Scott; Arnold, Paul; Nudo, Randolph J.

    2014-01-01

    Object The purpose of the present study was to determine the feasibility of using a common laboratory rat strain for locating cortical motor representations of the hindlimb reliably. Methods Intracortical Microstimulation (ICMS) techniques were used to derive detailed maps of the hindlimb motor representations in six adult Fischer-344 rats. Results The organization of the hindlimb movement representation, while variable across individuals in topographic detail, displayed several commonalities. The hindlimb representation was positioned posterior to the forelimb motor representation and postero-lateral to the motor trunk representation. The areal extent of the hindlimb representation across the cortical surface averaged 2.00 +/− 0.50 mm2. Superimposing individual maps revealed an overlapping area measuring 0.35 mm2, indicating that the location of the hindlimb representation can be predicted reliably based on stereotactic coordinates. Across the sample of rats, the hindlimb representation was found 1.25–3.75 mm posterior to Bregma, with an average center location ~ 2.6 mm posterior to Bregma. Likewise, the hindlimb representation was found 1–3.25 mm lateral to the midline, with an average center location ~ 2 mm lateral to midline. Conclusions The location of the cortical hindlimb motor representation in Fischer-344 rats can be reliably located based on its stereotactic position posterior to Bregma and lateral to the longitudinal skull suture at midline. The ability to accurately predict the cortical localization of functional hindlimb territories in a rodent model is important, as such animal models are being used increasingly in the development of brain-computer interfaces for restoration of function after spinal cord injury. PMID:23725395

  15. Recent results of the investigation of a micro-fluidic sampling chip and sampling system for hot cell aqueous processing streams

    International Nuclear Information System (INIS)

    Tripp, J.; Smith, T.; Law, J.

    2013-01-01

    A Fuel Cycle Research and Development project has investigated an innovative sampling method that could evolve into the next generation sampling and analysis system for metallic elements present in aqueous processing streams. Initially sampling technologies were evaluated and micro-fluidic sampling chip technology was selected and tested. A conceptual design for a fully automated microcapillary-based system was completed and a robotic automated sampling system was fabricated. The mechanical and sampling operation of the completed sampling system was investigated. Different sampling volumes have been tested. It appears that the 10 μl volume has produced data that had much smaller relative standard deviations than the 2 μl volume. In addition, the production of a less expensive, mass produced sampling chip was investigated to avoid chip reuse thus increasing sampling reproducibility/accuracy. The micro-fluidic-based robotic sampling system's mechanical elements were tested to ensure analytical reproducibility and the optimum robotic handling of micro-fluidic sampling chips. (authors)

  16. Tank Farm WM-182 and WM-183 Heel Slurry Samples PSD Results

    International Nuclear Information System (INIS)

    Batcheller, T.A.; Huestis, G.M.

    2000-01-01

    Particle size distribution (PSD) analysis of INTEC Tank Farm WM-182 and WM-183 heel slurry samples were performed using a modified Horiba LA-300 PSD analyzer at the RAL facility. There were two types of testing performed: typical PSD analysis, and setting rate testing. Although the heel slurry samples were obtained from two separate vessels, the particle size distribution results were quite similar. The slurry solids were from approximately a minimum particle size of 0.5 mm to a maximum of 230 mm with about 90% of the material between 2-to-133 mm, and the cumulative 50% value at approximately 20 mm. This testing also revealed that high frequency sonication with an ultrasonic element may break-up larger particles in the WM-182 and WM-183 tank from heel slurries. This finding represents useful information regarding ultimate tank heel waste processing. Settling rate testing results were also fairly consistent with material from both vessels in that it appears that most of the mass of solids settle to an agglomerated, yet easily redispersed layer at the bottom. A dispersed and suspended material remained in the ''clear'' layer above the settled layer after about one-half an hour of settling time. This material had a statistical mode of approximately 5 mm and a maximum particle size of 30 mm

  17. Overt and covert attention to location-based reward.

    Science.gov (United States)

    McCoy, Brónagh; Theeuwes, Jan

    2018-01-01

    Recent research on the impact of location-based reward on attentional orienting has indicated that reward factors play an influential role in spatial priority maps. The current study investigated whether and how reward associations based on spatial location translate from overt eye movements to covert attention. If reward associations can be tied to locations in space, and if overt and covert attention rely on similar overlapping neuronal populations, then both overt and covert attentional measures should display similar spatial-based reward learning. Our results suggest that location- and reward-based changes in one attentional domain do not lead to similar changes in the other. Specifically, although we found similar improvements at differentially rewarded locations during overt attentional learning, this translated to the least improvement at a highly rewarded location during covert attention. We interpret this as the result of an increased motivational link between the high reward location and the trained eye movement response acquired during learning, leading to a relative slowing during covert attention when the eyes remained fixated and the saccade response was suppressed. In a second experiment participants were not required to keep fixated during the covert attention task and we no longer observed relative slowing at the high reward location. Furthermore, the second experiment revealed no covert spatial priority of rewarded locations. We conclude that the transfer of location-based reward associations is intimately linked with the reward-modulated motor response employed during learning, and alternative attentional and task contexts may interfere with learned spatial priorities. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Infrastructure and industrial location : a dual technology approach

    OpenAIRE

    Bjorvatn, Kjetil

    2001-01-01

    The paper investigates how differences in infrastructure quality may affect industrial location between countries. Employing a dualtechnology model, the main result of the paper is the somewhat surprising conclusion that an improvement in a country’s infrastructure may weaken its locational advantage and induce a firm to locate production in a country with a less efficient infrastructure.

  19. Location-Dependent Query Processing Under Soft Real-Time Constraints

    Directory of Open Access Journals (Sweden)

    Zoubir Mammeri

    2009-01-01

    Full Text Available In recent years, mobile devices and applications achieved an increasing development. In database field, this development required methods to consider new query types like location-dependent queries (i.e. the query results depend on the query issuer location. Although several researches addressed problems related to location-dependent query processing, a few works considered timing requirements that may be associated with queries (i.e., the query results must be delivered to mobile clients on time. The main objective of this paper is to propose a solution for location-dependent query processing under soft real-time constraints. Hence, we propose methods to take into account client location-dependency and to maximize the percentage of queries respecting their deadlines. We validate our proposal by implementing a prototype based on Oracle DBMS. Performance evaluation results show that the proposed solution optimizes the percentage of queries meeting their deadlines and the communication cost.

  20. The Improved Locating Algorithm of Particle Filter Based on ROS Robot

    Science.gov (United States)

    Fang, Xun; Fu, Xiaoyang; Sun, Ming

    2018-03-01

    This paperanalyzes basic theory and primary algorithm of the real-time locating system and SLAM technology based on ROS system Robot. It proposes improved locating algorithm of particle filter effectively reduces the matching time of laser radar and map, additional ultra-wideband technology directly accelerates the global efficiency of FastSLAM algorithm, which no longer needs searching on the global map. Meanwhile, the re-sampling has been largely reduced about 5/6 that directly cancels the matching behavior on Roboticsalgorithm.

  1. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2010

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2010-01-08

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by Pacific Northwest National Laboratory for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford Site environs per regulatory requirements. This document contains the calendar year 2010 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and the Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2010, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2010.

  2. An intercomparison of sampling techniques among five European laboratories for measurements of radiocaesium in upland pasture and soil

    International Nuclear Information System (INIS)

    Nielsen, S.P.; Aarkrog, A.; Colgan, P.A.; McGee, E.; Synnott, H.J.; Johansson, K.J.; Horrill, A.D.; Kennedy, V.H.; Barbayiannis, N.

    1992-02-01

    An intercomparison of sampling procedures used by five European laboratories for the determination of radiocaesium in vegetation and peaty soil was carried out at two locations in Cumbria. The soil sampling procedures included th ecollection of depth profiles in order to obtain information on the vertical distribution of radiocaesium in addition to the total deposition. The number of samples taken by each laboratory varied from one to five. The multiple sampling has given information on the homogeneity of the parameters studied at each location. The parameters comprise soil bulk densities, total deposition of 137 Cs, deposition of 137 Cs in three soil layers, biomass densities, concentrations of 137 Cs in pasture, and activity ratios ( 134 Cs/ 137 Cs) in soil and vegetation. The determination of total deposition of 137 Cs gave no indication of differences between the laboratories. The total depositions of 134 Cs and 137 Cs observed at one site were compared with levels obtained from another study and the two sets of data were found to be in good agreement. The results from the soil profiles do indicate significant differences between laboratories. This covers the vertical distributions of 137 Cs deposition including the 134 Cs/ 137 Cs-activity ratios as well as the soil bulk densities. One laboratory using a coring technique observed difficulties during sampling due to compression of the soil. The coring technique should thus be avoided or applied with extreme care for the sampling of depth profiles in peaty soil. The results from the sampling of pasture show no indication of differences between the laboratories. For the parameters studied the observed variabilities across soil depths and locations range from 10% to 82% in terms of relative standard deviations. A comparison across all results at the two locations indicate a 50% higher field variability at one of the sites relative to the other. (au) (24 tabs., 9 ills., 3 refs.)

  3. Characterization of ice nucleating particles during continuous springtime measurements in Prudhoe Bay: an Arctic oilfield location

    Science.gov (United States)

    Creamean, J.; Spada, N. J.; Kirpes, R.; Pratt, K.

    2017-12-01

    Aerosols that serve as ice nucleating particles (INPs) have the potential to modulate cloud microphysical properties. INPs can thus subsequently impact cloud radiative forcing in addition to modification of precipitation formation processes. In regions such as the Arctic, aerosol-cloud interactions are severely understudied yet have significant implications for surface radiation reaching the sea ice and snow surfaces. Further, uncertainties in model representations of heterogeneous ice nucleation are a significant hindrance to simulating Arctic mixed-phase cloud processes. Characterizing a combination of aerosol chemical, physical, and ice nucleating properties is pertinent to evaluating of the role of aerosols in altering Arctic cloud microphysics. We present preliminary results from an aerosol sampling campaign called INPOP (Ice Nucleating Particles at Oliktok Point), which took place at a U.S. Department of Energy's Atmospheric Radiation Measurement (DOE ARM) facility on the North Slope of Alaska. Three time- and size-resolved aerosol samplers were deployed from 1 Mar to 31 May 2017 and were co-located with routine measurements of aerosol number, size, chemical, and radiative property measurements conducted by DOE ARM at their Aerosol Observing System (AOS). Offline analysis of samples collected at a daily time resolution included composition and morphology via single-particle analysis and drop freezing measurements for INP concentrations, while analysis of 12-hourly samples included mass, optical, and elemental composition. We deliberate the possible influences on the aerosol and INP population from the Prudhoe Bay oilfield resource extraction and daily operations in addition to what may be local background or long-range transported aerosol. To our knowledge our results represent some of the first INP characterization measurements in an Arctic oilfield location and can be used as a benchmark for future INP characterization studies in Arctic locations impacted

  4. Bias correction of bounded location errors in presence-only data

    Science.gov (United States)

    Hefley, Trevor J.; Brost, Brian M.; Hooten, Mevin B.

    2017-01-01

    Location error occurs when the true location is different than the reported location. Because habitat characteristics at the true location may be different than those at the reported location, ignoring location error may lead to unreliable inference concerning species–habitat relationships.We explain how a transformation known in the spatial statistics literature as a change of support (COS) can be used to correct for location errors when the true locations are points with unknown coordinates contained within arbitrary shaped polygons.We illustrate the flexibility of the COS by modelling the resource selection of Whooping Cranes (Grus americana) using citizen contributed records with locations that were reported with error. We also illustrate the COS with a simulation experiment.In our analysis of Whooping Crane resource selection, we found that location error can result in up to a five-fold change in coefficient estimates. Our simulation study shows that location error can result in coefficient estimates that have the wrong sign, but a COS can efficiently correct for the bias.

  5. Headspace vapor characterization of Hanford waste tank 241-U-109: Results from samples collected on 8/10/95

    International Nuclear Information System (INIS)

    Evans, J.C.; Thomas, B.L.; Pool, K.H.; Olsen, K.B.; Fruchter, J.S.; Silvers, K.L.

    1996-05-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-U-109 (Tank U-109) At the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank farm operations. This tank is on the Hydrogen Waste List. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, sample volumes provided by WHC. A summary of the inorganic analytes, permanent gases and total non-methane hydrocarbons is listed in a table. The three highest concentration analytes detected in SUMMA trademark canister and triple sorbent trap samples is also listed in the table. Detailed descriptions of the analytical results appear in the text

  6. Detection and Molecular Characterization of Gemycircularvirus from Environmental Samples in Brazil.

    Science.gov (United States)

    da Silva Assis, Matheus Ribeiro; Vieira, Carmen Baur; Fioretti, Julia Monassa; Rocha, Mônica Simões; de Almeida, Pedro Ivo Neves; Miagostovich, Marize Pereira; Fumian, Tulio Machado

    2016-12-01

    Gemycircularvirus (GemyCV) is a group of viruses which has been recently proposed as a new viral genus detected in fecal and environmental samples around the world. GemyCVs have been detected in human blood, brain tissue, cerebrospinal fluid, and stool sample. In the present study, we demonstrate for the first time, through molecular detection and characterization, the presence of GemyCVs in environmental samples from Brazil. Our results show a percentage of positivity ranging from 69 (25/36) to 97 % (35/36) in river water samples collected in Manaus, Amazon region, and wastewater from a wastewater treatment plant located in Rio de Janeiro, respectively, revealing GemyCVs as an important environmental contaminant.

  7. Results of the radon concentration survey in Sibiu county underground water

    International Nuclear Information System (INIS)

    Chicea, Dan; Cosma, Constantin

    2002-01-01

    In November 2000 a survey of radon ( 222 Rn) concentration in Sibiu county underground water was conducted. The radon concentration was measured with a A LUK 3A. The radon gas was extracted from water using the LUK VR device that works with LUK 3A. All samples were taken in 0.5 l recipients that were filled and sealed. Samples from eighteen cities and villages were taken. Special care was taken for the samples to be carefully brought to room temperature and not to be agitated or stirred before measuring the radon concentration. In measuring the radon concentration corrections like the solubility coefficient variation with temperature, the radon concentration increase in air in time and the background correction were applied. Results reveal that the underground water radon concentration is bigger in wells located in mountainous area, has an average value in wells from hilly region and is considerable lower in wells located in plain area. Another thing we noticed is that the samples taken from the city water pipe system present lower radon concentration values than the samples taken from home drilled wells. The minimum radon concentration value was found in the drinking water of Sibiu city, 1.6 Bq/l and in Sadu village, 1.965 Bq/l. The highest measured values are 28.1 Bq/l in Rasinari, a village located at the bottom of the mountains and 26.4 Bq/l, in Sibiel, a village 30 km away from the first one. These results reveal that the radon concentration values measured in Sibiu county are comparable with the measured values reported in literature and well below the maximum acceptable values. (authors)

  8. Indoor location-based services prerequisites and foundations

    CERN Document Server

    Werner, Martin

    2014-01-01

    This book delivers concise coverage of classical methods and new developments related to indoor location-based services. It collects results from isolated domains including geometry, artificial intelligence, statistics, cooperative algorithms, and distributed systems and thus provides an accessible overview of fundamental methods and technologies. This makes it an ideal starting point for researchers, students, and professionals in pervasive computing. Location-based services are services using the location of a mobile computing device as their primary input. While such services are fairly e

  9. Passive Acoustic Source Localization at a Low Sampling Rate Based on a Five-Element Cross Microphone Array

    Directory of Open Access Journals (Sweden)

    Yue Kan

    2015-06-01

    Full Text Available Accurate acoustic source localization at a low sampling rate (less than 10 kHz is still a challenging problem for small portable systems, especially for a multitasking micro-embedded system. A modification of the generalized cross-correlation (GCC method with the up-sampling (US theory is proposed and defined as the US-GCC method, which can improve the accuracy of the time delay of arrival (TDOA and source location at a low sampling rate. In this work, through the US operation, an input signal with a certain sampling rate can be converted into another signal with a higher frequency. Furthermore, the optimal interpolation factor for the US operation is derived according to localization computation time and the standard deviation (SD of target location estimations. On the one hand, simulation results show that absolute errors of the source locations based on the US-GCC method with an interpolation factor of 15 are approximately from 1/15- to 1/12-times those based on the GCC method, when the initial same sampling rates of both methods are 8 kHz. On the other hand, a simple and small portable passive acoustic source localization platform composed of a five-element cross microphone array has been designed and set up in this paper. The experiments on the established platform, which accurately locates a three-dimensional (3D near-field target at a low sampling rate demonstrate that the proposed method is workable.

  10. Problematic Social Media Use: Results from a Large-Scale Nationally Representative Adolescent Sample.

    Directory of Open Access Journals (Sweden)

    Fanni Bányai

    Full Text Available Despite social media use being one of the most popular activities among adolescents, prevalence estimates among teenage samples of social media (problematic use are lacking in the field. The present study surveyed a nationally representative Hungarian sample comprising 5,961 adolescents as part of the European School Survey Project on Alcohol and Other Drugs (ESPAD. Using the Bergen Social Media Addiction Scale (BSMAS and based on latent profile analysis, 4.5% of the adolescents belonged to the at-risk group, and reported low self-esteem, high level of depression symptoms, and elevated social media use. Results also demonstrated that BSMAS has appropriate psychometric properties. It is concluded that adolescents at-risk of problematic social media use should be targeted by school-based prevention and intervention programs.

  11. Long-term frozen storage of urine samples: a trouble to get PCR results in Schistosoma spp. DNA detection?

    Science.gov (United States)

    Fernández-Soto, Pedro; Velasco Tirado, Virginia; Carranza Rodríguez, Cristina; Pérez-Arellano, José Luis; Muro, Antonio

    2013-01-01

    Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples' storage or conditions for handling and DNA preservation and extraction methods. We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patients urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template. Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA method of extraction used.

  12. Results of detailed ground geophysical surveys for locating and differentiating waste structures in waste management area 'A' at Chalk River Laboratories, Ontario

    Energy Technology Data Exchange (ETDEWEB)

    Tomsons, D.K.; Street, P.J.; Lodha, G.S

    1999-07-01

    Waste Management Area 'A' (WMA 'A'), located in the outer area of the Chalk River Laboratories (CRL) was in use as a waste burial site from 1946 to 1955. Waste management structures include debris-filled trenches, concrete bunkers and miscellaneous contaminated solid materials, and ditches and pits used for liquid dispersal. In order to update historical records, it was proposed to conduct detailed ground geophysical surveys to define the locations of waste management structures in WMA 'A', assist in planning of the drilling and sampling program to provide ground truth for the geophysics investigation and to predict the nature and locations of unknown/undefined shallow structures. A detailed ground geophysical survey grid was established with a total of 127 grid lines, oriented NNE and spaced one metre apart. The geophysical surveys were carried out during August and September, 1996. The combination of geophysical tools used included the Geonics EM61 metal detector, the GSM-19 magnetometer/gradiometer and a RAMAC high frequency ground penetrating radar system. The geophysical surveys were successful in identifying waste management structures and in characterizing to some extent, the composition of the waste. The geophysical surveys are able to determine the presence of most of the known waste management structures, especially in the western and central portions of the grid which contain the majority of the metallic waste. The eastern portion of the grid has a completely different geophysical character. While historical records show that trenches were dug, they are far less evident in the geophysical record. There is clear evidence for a trench running between lines 30E and 63E at 70 m. There are indications from the radar survey of other trench-like structures in the eastern portion. EM61 data clearly show that there is far less metallic debris in the eastern portion. The geophysical surveys were also successful in identifying

  13. Bodily ownership and self-location

    DEFF Research Database (Denmark)

    Serino, Andrea; Alsmith, Adrian John Tetteh; Costantini, Marcello

    2013-01-01

    Recent research on bodily self-consciousness has assumed that it consists of three distinct components: the experience of owning a body (body ownership); the experience of being a body with a given location within the environment (self-location); and the experience of taking a first-person, body......-centered, perspective on that environment (perspective). Here we review recent neuroimaging studies suggesting that at least two of these components—body ownership and self-location—are implemented in rather distinct neural substrates, located, respectively, in the premotor cortex and in the temporo-parietal junction....... We examine these results and consider them in relation to clinical evidence from patients with altered body perception and work on a variety of multisensory, body-related illusions, such as the rubber hand illusion, the full body illusion, the body swap illusion and the enfacement illusion. We...

  14. P2-13: Location word Cues' Effect on Location Discrimination Task: Cross-Modal Study

    Directory of Open Access Journals (Sweden)

    Satoko Ohtsuka

    2012-10-01

    Full Text Available As is well known, participants are slower and make more errors in responding to the display color of an incongruent color word than a congruent one. This traditional stroop effect is often accounted for with relatively automatic and dominant word processing. Although the word dominance account has been widely supported, it is not clear in what extent of perceptual tasks it is valid. Here we aimed to examine whether the word dominance effect is observed in location stroop tasks and in audio-visual situations. The participants were required to press a key according to the location of visual (Experiment 1 and audio (Experiment 2 targets, left or right, as soon as possible. A cue of written (Experiments 1a and 2a or spoken (Experiments 1b and 2b location words, “left” or “right”, was presented on the left or right side of the fixation with cue lead times (CLT of 200 ms and 1200 ms. Reaction time from target presentation to key press was recorded as a dependent variable. The results were that the location validity effect was marked in within-modality but less so in cross-modality trials. The word validity effect was strong in within- but not in cross-modality trials. The CLT gave some effect of inhibition of return. So the word dominance could be less effective in location tasks and in cross-modal situations. The spatial correspondence seems to overcome the word effect.

  15. Sample similarity analysis of angles of repose based on experimental results for DEM calibration

    Science.gov (United States)

    Tan, Yuan; Günthner, Willibald A.; Kessler, Stephan; Zhang, Lu

    2017-06-01

    As a fundamental material property, particle-particle friction coefficient is usually calculated based on angle of repose which can be obtained experimentally. In the present study, the bottomless cylinder test was carried out to investigate this friction coefficient of a kind of biomass material, i.e. willow chips. Because of its irregular shape and varying particle size distribution, calculation of the angle becomes less applicable and decisive. In the previous studies only one section of those uneven slopes is chosen in most cases, although standard methods in definition of a representable section are barely found. Hence, we presented an efficient and reliable method from the new technology, 3D scan, which was used to digitize the surface of heaps and generate its point cloud. Then, two tangential lines of any selected section were calculated through the linear least-squares regression (LLSR), such that the left and right angle of repose of a pile could be derived. As the next step, a certain sum of sections were stochastic selected, and calculations were repeated correspondingly in order to achieve sample of angles, which was plotted in Cartesian coordinates as spots diagram. Subsequently, different samples were acquired through various selections of sections. By applying similarities and difference analysis of these samples, the reliability of this proposed method was verified. Phased results provides a realistic criterion to reduce the deviation between experiment and simulation as a result of random selection of a single angle, which will be compared with the simulation results in the future.

  16. Sample similarity analysis of angles of repose based on experimental results for DEM calibration

    Directory of Open Access Journals (Sweden)

    Tan Yuan

    2017-01-01

    Full Text Available As a fundamental material property, particle-particle friction coefficient is usually calculated based on angle of repose which can be obtained experimentally. In the present study, the bottomless cylinder test was carried out to investigate this friction coefficient of a kind of biomass material, i.e. willow chips. Because of its irregular shape and varying particle size distribution, calculation of the angle becomes less applicable and decisive. In the previous studies only one section of those uneven slopes is chosen in most cases, although standard methods in definition of a representable section are barely found. Hence, we presented an efficient and reliable method from the new technology, 3D scan, which was used to digitize the surface of heaps and generate its point cloud. Then, two tangential lines of any selected section were calculated through the linear least-squares regression (LLSR, such that the left and right angle of repose of a pile could be derived. As the next step, a certain sum of sections were stochastic selected, and calculations were repeated correspondingly in order to achieve sample of angles, which was plotted in Cartesian coordinates as spots diagram. Subsequently, different samples were acquired through various selections of sections. By applying similarities and difference analysis of these samples, the reliability of this proposed method was verified. Phased results provides a realistic criterion to reduce the deviation between experiment and simulation as a result of random selection of a single angle, which will be compared with the simulation results in the future.

  17. Location of power stations and measures for local people model analysis concerning location negotiation with local fishery association

    International Nuclear Information System (INIS)

    Wakatani, Yoshifumi; Yamanaka, Yoshiro

    1982-01-01

    The recent negotiation of enterprisers and local people concerning the location of power stations tends to extend for long period because of diversified arguing points and the information exchange of high density, and also to be complicated by the interrelation with other points. It is a large problem to seek the policy of such negotiation for enterprisers to respond to local people. In this study, as the first step, the policy and action appeared in location negotiations and the development of the negotiations were analyzed on the cases of location, and two kinds of the model analysis were carried out, taking fishery compensation negotiation as the object among them. The knowledge was obtained about what response to local fishery associations is effective to promote the location. The classification of location negotiation and the factors affecting the development of negotiation were investigated. It was shown to be effective to divide the process of location negotiation into five stages of advancement. The model analysis was carried out according to game theory and by gaming simulation method. The results are reported. (Kako, I.)

  18. Location of power stations and measures for local people model analysis concerning location negotiation with local fishery association

    Energy Technology Data Exchange (ETDEWEB)

    Wakatani, Yoshifumi; Yamanaka, Yoshiro (Central Research Inst. of electric Power Industry, Tokyo (Japan))

    1982-05-01

    The recent negotiation of enterprisers and local people concerning the location of power stations tends to extend for long periods because of diversified arguing points and the information exchange of high density, and also to be complicated by the interrelation with other points. It is a large problem to seek the policy of such negotiation for enterprisers to respond to local people. In this study, as the first step, the policy and action appeared in location negotiations and the development of the negotiations were analyzed on the cases of location, and two kinds of the model analysis were carried out, taking fishery compensation negotiation as the object among them. The knowledge was obtained about what response to local fishery associations is effective to promote the location. The classification of location negotiation and the factors affecting the development of negotiation were investigated. It was shown to be effective to divide the process of location negotiation into five stages of advancement. The model analysis was carried out according to game theory and by gaming simulation method. The results are reported.

  19. The results of experimental studies of VLF–ULF electromagnetic emission by rock samples due to mechanical action

    OpenAIRE

    A. A. Panfilov

    2013-01-01

    The paper presents the results of laboratory experiments on electromagnetic emission excitation (electric component of electromagnetic field) by rock samples due to different forms of mechanical stress applications. It was shown that samples generate electric impulses with different spectra when the impact action, gradual loading or dynamic friction is applied. It was ascertained that level and spectral compositions of signals, generated by rock samples, cha...

  20. The variance quadtree algorithm: use for spatial sampling design

    NARCIS (Netherlands)

    Minasny, B.; McBratney, A.B.; Walvoort, D.J.J.

    2007-01-01

    Spatial sampling schemes are mainly developed to determine sampling locations that can cover the variation of environmental properties in the area of interest. Here we proposed the variance quadtree algorithm for sampling in an area with prior information represented as ancillary or secondary

  1. Failure analysis of burst tested fuel tube samples

    International Nuclear Information System (INIS)

    Padmaprabu, C.; Ramana Rao, S.V.; Srivatsava, R.K.

    2005-01-01

    The Total Circumferential Elongation (TCE) is an important parameter for evaluation of ductility of the Zircaloy-4 fuel tubes for the PHWR reactors. The TCE values of the fuel tubes were obtained using the burst testing technique. In some lots there is a variation in the values of the TCE. To investigate the reasons for such a large variation in the TCE, samples were selected at appropriate intervals and sectioned at the fractured portion. The surface morphology of the fractured surfaces was examined under Scanning Electron Microscope (SEM) equipped with Energy Dispersive Spectrometer (EDS). The morphologies show segregation of elements at specific locations. Energy dispersive spectra was obtained from those segregated particles. According to the magnitude of TCE value the samples were classified into low, intermediate and high ductility. Low ductility samples were found to contain large amount of segregations along the thickness direction of the tube. This forms a brittle region and a path for the easy crack growth along thickness direction. In the case of intermediate samples the segregation occurred in fewer locations compared to low ductile samples and also confined to the circumferential direction of the outside surface of the tube. Due to this, probability of crack formation at the surface of the tube could be high. But crack growth would be slower in the ductile matrix along the thickness direction resulting in the enhancement of TCE value compared to the low ductile sample. In the high ductile samples, the segregations were very scarce and found to be isolated and embedded in the ductile matrix. The mode of failure in these types of samples was found to be purely ductile. Cracks were found to originate solely from the micro voids in the material. As the probability of crack formation and its propagation is low, very high TCE values were observed in these samples. Microstructural observations of fractured surfaces and EDAX analysis was able to identify the

  2. Gap-Filling of Landsat 7 Imagery Using the Direct Sampling Method

    KAUST Repository

    Yin, Gaohong

    2016-12-28

    The failure of the Scan Line Corrector (SLC) on Landsat 7 imposed systematic data gaps on retrieved imagery and removed the capacity to provide spatially continuous fields. While a number of methods have been developed to fill these gaps, most of the proposed techniques are only applicable over relatively homogeneous areas. When they are applied to heterogeneous landscapes, retrieving image features and elements can become challenging. Here we present a gap-filling approach that is based on the adoption of the Direct Sampling multiple-point geostatistical method. The method employs a conditional stochastic resampling of known areas in a training image to simulate unknown locations. The approach is assessed across a range of both homogeneous and heterogeneous regions. Simulation results show that for homogeneous areas, satisfactory results can be obtained by simply adopting non-gap locations in the target image as baseline training data. For heterogeneous landscapes, bivariate simulations using an auxiliary variable acquired at a different date provides more accurate results than univariate simulations, especially as land cover complexity increases. Apart from recovering spatially continuous fields, one of the key advantages of the Direct Sampling is the relatively straightforward implementation process that relies on relatively few parameters.

  3. Trace element contamination in feather and tissue samples from Anna’s hummingbirds

    Science.gov (United States)

    Mikoni, Nicole A.; Poppenga, Robert H.; Ackerman, Joshua T.; Foley, Janet E.; Hazlehurst, Jenny; Purdin, Güthrum; Aston, Linda; Hargrave, Sabine; Jelks, Karen; Tell, Lisa A.

    2017-01-01

    Trace element contamination (17 elements; Be, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Mo, Cd, Ba, Hg, Tl, and Pb) of live (feather samples only) and deceased (feather and tissue samples) Anna's hummingbirds (Calypte anna) was evaluated. Samples were analyzed using inductively coupled plasma-mass spectrometry (ICP-MS; 17 elements) and atomic absorption spectrophotometry (Hg only). Mean plus one standard deviation (SD) was considered the benchmark, and concentrations above the mean + 1 SD were considered elevated above normal. Contour feathers were sampled from live birds of varying age, sex, and California locations. In order to reduce thermal impacts, minimal feathers were taken from live birds, therefore a novel method was developed for preparation of low mass feather samples for ICP-MS analysis. The study found that the novel feather preparation method enabled small mass feather samples to be analyzed for trace elements using ICP-MS. For feather samples from live birds, all trace elements, with the exception of beryllium, had concentrations above the mean + 1 SD. Important risk factors for elevated trace element concentrations in feathers of live birds were age for iron, zinc, and arsenic, and location for iron, manganese, zinc, and selenium. For samples from deceased birds, ICP-MS results from body and tail feathers were correlated for Fe, Zn, and Pb, and feather concentrations were correlated with renal (Fe, Zn, Pb) or hepatic (Hg) tissue concentrations. Results for AA spectrophotometry analyzed samples from deceased birds further supported the ICP-MS findings where a strong correlation between mercury concentrations in feather and tissue (pectoral muscle) samples was found. These study results support that sampling feathers from live free-ranging hummingbirds might be a useful, non-lethal sampling method for evaluating trace element exposure and provides a sampling alternative since their small body size limits traditional sampling of blood and tissues. The

  4. Location of airports - selected quantitative methods

    Directory of Open Access Journals (Sweden)

    Agnieszka Merkisz-Guranowska

    2016-09-01

    Full Text Available Background: The role of air transport in  the economic development of a country and its regions cannot be overestimated. The decision concerning an airport's location must be in line with the expectations of all the stakeholders involved. This article deals with the issues related to the choice of  sites where airports should be located. Methods: Two main quantitative approaches related to the issue of airport location are presented in this article, i.e. the question of optimizing such a choice and the issue of selecting the location from a predefined set. The former involves mathematical programming and formulating the problem as an optimization task, the latter, however, involves ranking the possible variations. Due to various methodological backgrounds, the authors present the advantages and disadvantages of both approaches and point to the one which currently has its own practical application. Results: Based on real-life examples, the authors present a multi-stage procedure, which renders it possible to solve the problem of airport location. Conclusions: Based on the overview of literature of the subject, the authors point to three types of approach to the issue of airport location which could enable further development of currently applied methods.

  5. In vitro comparison of working length determination using three different electronic apex locators

    Directory of Open Access Journals (Sweden)

    Alper Kuştarci

    2014-01-01

    Full Text Available Background: The aim of this study was to compare the accuracy of the apex-locating functions of DentaPort ZX, Raypex 5 and Endo Master electronic apex locators (EALs in vitro. Materials and Methods: Thirty extracted human single-rooted teeth with mature apices were used for the study. The real working length (RWL was established by subtracting 0.5 mm from the actual root canal length. All teeth were mounted in an alginate model that was especially developed to test the EALs and the teeth were then measured with each EAL. The results were compared with the corresponding RWL, which was subtracted from the electronically determined distance. Data were analyzed using a paired-samples t-test, a Chi-square test and a repeated measure analysis of variance evaluation at the 0.05 level of significance. Results: Statistical analysis showed that no significant difference was found among all EALs (P > 0.05. Conclusion: The accuracy of the EALs was evaluated and all of the devices showed an acceptable determination of electronic working length between the ranges of ±0.5 mm.

  6. Sampling challenges in a study examining refugee resettlement

    Directory of Open Access Journals (Sweden)

    Thompson Sandra C

    2011-03-01

    Full Text Available Abstract Background As almost half of all refugees currently under United Nations protection are from Afghanistan or Iraq and significant numbers have already been resettled outside the region of origin, it is likely that future research will examine their resettlement needs. A number of methodological challenges confront researchers working with culturally and linguistically diverse groups; however, few detailed articles are available to inform other studies. The aim of this paper is to outline challenges with sampling and recruitment of socially invisible refugee groups, describing the method adopted for a mixed methods exploratory study assessing mental health, subjective wellbeing and resettlement perspectives of Afghan and Kurdish refugees living in New Zealand and Australia. Sampling strategies used in previous studies with similar refugee groups were considered before determining the approach to recruitment Methods A snowball approach was adopted for the study, with multiple entry points into the communities being used to choose as wide a range of people as possible to provide further contacts and reduce selection bias. Census data was used to assess the representativeness of the sample. Results A sample of 193 former refugee participants was recruited in Christchurch (n = 98 and Perth (n = 95, 47% were of Afghan and 53% Kurdish ethnicity. A good gender balance (males 52%, females 48% was achieved overall, mainly as a result of the sampling method used. Differences in the demographic composition of groups in each location were observed, especially in relation to the length of time spent in a refugee situation and time since arrival, reflecting variations in national humanitarian quota intakes. Although some measures were problematic, Census data comparison to assess reasonable representativeness of the study sample was generally reassuring. Conclusions Snowball sampling, with multiple initiation points to reduce selection bias, was

  7. KCBX Petroleum Coke Storage Pile Sampling Logbook and Photos

    Science.gov (United States)

    This documentation of KCBX's petcoke sampling locations and methods demonstrates adherence to the pet coke sampling plan previously submitted and approved by EPA, at both North Terminal and South Terminal stockpiles.

  8. Solvent Hold Tank Sample Results for MCU-16-991-992-993: July 2016 Monthly sample and MCU-16-1033-1034-1035: July 2016 Superwashed Sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-11-25

    SRNL received one set of SHT samples (MCU-16-991, MCU-16-992 and MCU-16-993), pulled on 07/13/2016 and another set of SHT samples (MCU-16-1033, MCU-16-1034, and MCU-16-1035) that were pulled on 07/24/2016 after the solvent was superwashed with 300 mM sodium hydroxide for analysis. Samples MCU-16-991, MCU-16-992, and MCU-16-993 were combined into one sample (MCU-16-991-992-993) and samples MCU-16-1033, MCU-16-1034, and MCU-16-1035 were combined into one sample (MCU-16-1033-1034-1035). Of the two composite samples MCU-16-1033-1034-1035 represents the current chemical state of the solvent at MCU. All analytical conclusions are based on the chemical analysis of MCU-16-1033-1034-1035. There were no chemical differences between MCU-16- 991-992-993 and superwashed MCU-16-1033-1034-1035.

  9. Vapor space characterization of Waste Tank 241-C-103: Inorganic results from sample Job 7B (May 12-25, 1994)

    International Nuclear Information System (INIS)

    Ligotke, M.W.; Pool, K.H.; Lerner, B.D.

    1994-10-01

    This report is to provide analytical results for use in safety and toxicological evaluations of the vapor space of Hanford single-shell waste storage tanks C-103. Samples were analysed to determine concentrations of ammonia, nitric oxide, nitrogen dioxide, sulfur oxides, and hydrogen cyanide. In addition to the samples, controls were analyzed that included blanks, spiked blanks, and spiked samples. These controls provided information about the suitability of sampling and analytical methods. Also included are the following: information describing the methods and sampling procedures used; results of sample analyses; and Conclusions and recommendations

  10. Spectral triangulation: a 3D method for locating single-walled carbon nanotubes in vivo

    Science.gov (United States)

    Lin, Ching-Wei; Bachilo, Sergei M.; Vu, Michael; Beckingham, Kathleen M.; Bruce Weisman, R.

    2016-05-01

    Nanomaterials with luminescence in the short-wave infrared (SWIR) region are of special interest for biological research and medical diagnostics because of favorable tissue transparency and low autofluorescence backgrounds in that region. Single-walled carbon nanotubes (SWCNTs) show well-known sharp SWIR spectral signatures and therefore have potential for noninvasive detection and imaging of cancer tumours, when linked to selective targeting agents such as antibodies. However, such applications face the challenge of sensitively detecting and localizing the source of SWIR emission from inside tissues. A new method, called spectral triangulation, is presented for three dimensional (3D) localization using sparse optical measurements made at the specimen surface. Structurally unsorted SWCNT samples emitting over a range of wavelengths are excited inside tissue phantoms by an LED matrix. The resulting SWIR emission is sampled at points on the surface by a scanning fibre optic probe leading to an InGaAs spectrometer or a spectrally filtered InGaAs avalanche photodiode detector. Because of water absorption, attenuation of the SWCNT fluorescence in tissues is strongly wavelength-dependent. We therefore gauge the SWCNT-probe distance by analysing differential changes in the measured SWCNT emission spectra. SWCNT fluorescence can be clearly detected through at least 20 mm of tissue phantom, and the 3D locations of embedded SWCNT test samples are found with sub-millimeter accuracy at depths up to 10 mm. Our method can also distinguish and locate two embedded SWCNT sources at distinct positions.Nanomaterials with luminescence in the short-wave infrared (SWIR) region are of special interest for biological research and medical diagnostics because of favorable tissue transparency and low autofluorescence backgrounds in that region. Single-walled carbon nanotubes (SWCNTs) show well-known sharp SWIR spectral signatures and therefore have potential for noninvasive detection and

  11. Sampling and analysis of 100 Area springs

    International Nuclear Information System (INIS)

    1992-02-01

    This report is submitted in fulfillment of Hanford Federal Facility Agreement and Consent Order Milestone M-30-01, submit a report to EPA and Ecology evaluating the impact to the Columbia River from contaminated springs and seeps as described in the operable unit work plans listed in M-30-03. Springs, seeps, sediments, and the Columbia River were sampled for chemical and radiological analyses during the period September 16 through October 21, 1991. A total of 26 locations were sampled. Results of these analyses show that radiological and nonradiological contaminants continue to enter the Columbia River from the retired reactor areas of the 100 Area via the springs. The primary contaminants in the springs are strontium-90, tritium, and chromium. These contaminants were detected in concentrations above drinking water standards. Analysis of total organic carbon were run on all water samples collected; there is no conclusive evidence that organic constituents are entering the river through the springs. Total organic carbon analyses were generally higher for the surface water than for the springs. The results of this study will be used to develop a focused, yet flexible, long-term spring sampling program. Analysis of Columbia River water samples collected at the Hanford Townsite (i.e., downstream of the reactor areas) did not detect any Hanford-specific contaminants

  12. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2009

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2009-01-20

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory for the U.S. Department of Energy. Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 450.1 and DOE Order 5400.5. This document contains the calendar year 2009 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2009, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2009.

  13. 2015 Long-Term Hydrologic Monitoring Program Sampling and Analysis Results Report for Project Rulison, Co

    Energy Technology Data Exchange (ETDEWEB)

    Findlay, Rick [Navarro Research and Engineering, Oak Ridge, TN (United States); Kautsky, Mark [US Department of Energy, Washington, DC (United States). Office of Legacy Management

    2015-12-01

    The U.S. Department of Energy (DOE) Office of Legacy Management conducted annual sampling at the Rulison, Colorado, Site for the Long-Term Hydrologic Monitoring Program (LTHMP) on May 20–22 and 27, 2015. Several of the land owners were not available to allow access to their respective properties, which created the need for several sample collection trips. This report documents the analytical results of the Rulison monitoring event and includes the trip report and the data validation package (Appendix A). The groundwater and surface water monitoring were shipped to the GEL Group Inc. laboratories for analysis. All requested analyses were successfully completed. Samples were analyzed for gamma-emitting radionuclides by high- resolution gamma spectrometry. Tritium was analyzed using two methods, the conventional tritium method, which has a detection limit on the order of 400 picocuries per liter (pCi/L), and the enriched method (for selected samples), which has a detection limit on the order of 3 pCi/L.

  14. TRACE ELEMENT CONTENTS IN TOPSOIL LOCATED NEAR STEEL PLANT IN KRAKOW-NOWA HUTA

    Directory of Open Access Journals (Sweden)

    Paweł Mundała

    2014-10-01

    Full Text Available The paper presents the results of cadmium, lead and zinc contents in topsoils of arable land located in vicinity Steel Plant in Krakow-Nowa Huta. Soil samples were collected in autumn 2007 from the 0-20 cm layer placed in a west-east trnsect of 7,5 km length. It started approximately 5km east form the border of the steel plant. .Sampled area is characterized by high level of agriculture, where the dominant crops have been vegetables, mainly cabbage and cauliflower. It was found, the soil was not contaminated with heavy metals. All samples met the requirements of the Polish Minister of the Environment. Also the assessment according to Institute of Soil Science and Plant Cultivation method showed only incerased content 60% in case of zinc and only 13% for Cd. Any levels of pollution were not observed. There also decreasing trend of accumulation were stated as a function of growing distance from the steel plant.

  15. Analysis of medicinal plants and soil sample from Haridwar region by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Maharia, R.S.; Dutta, R.K.; Acharya, R.; Reddy, A.V.R.

    2009-01-01

    Samples of leaves and stems of four medicinal plants namely Kalmegh, Amaltas, Moalshri, and Arusa were analysed by Instrumental Neutron Activation Analysis. Soil from same location was analyzed. Though concentrations of many elements were determined in the plant samples, results of selected elements namely Na, K, Mn, Fe, Co, Cr, Zn and As are discussed in this paper. The results show that all medicinal plants analyzed have lower elemental contents except Zn compared to the soil. (author)

  16. Location-Price Competition in Airline Networks

    Directory of Open Access Journals (Sweden)

    H. Gao

    2014-01-01

    Full Text Available This paper addresses location-then-price competition in airline market as a two-stage game of n players on the graph. Passenger’s demand distribution is described by multinomial logit model. Equilibrium in price game is computed through best response dynamics. We solve location game using backward induction, knowing that airlines will choose prices from equilibrium for the second-stage game. Some numerical results for airline market under consideration are presented.

  17. The application of soil-gas geochemistry to precisely locate La Victoria fault near Paracotos (Venezuela)

    International Nuclear Information System (INIS)

    LaBrecque, J.J.; Rosales, P.A.; Cordoves, P.R.

    1999-01-01

    Full text: Measurements of radon (total radon, Radon-222 and Radon-220) and other soil-gases (CO 2 , O 2 and H 2 ) were performed routinely during 1998 and 1999 across a narrow valley near Paracotos, Venezuela in an attempt to precisely locate the La Victoria fault. The transect was about 300 meters long with eleven sampling points. The soil-gas probes were inserted to a depth of 45 cm in the beginning and later on completely to a depth of 63 cm. The radon sampling and measurements were accomplished with a Pylon AB-5 radiation monitor and Lucas scintillation cells. The other soil-gases were directly determined with an Anagas, CD95 monitor and an Infra-red Gas Analyzer (MKIIC) both coupled with a Hydrogen pod. The radon values for more than twenty different sampling periods over a two year period resulted with anomalous values between 75 and 150 meters along the transect. There were three consecutive anomalous values each time. But strangely, the anomalies of the radon values were in the form of a doublet at 116 and 141 meters rather than a simple single peak in the middle and the gas flow was similar for the sampling points between 75 and 150 meters. The graph of the relative CO 2 values were usually similar to the radon graphs but in some cases, the anomalous values were seen as a simple single peak and corresponded to the 141 meter sampling point. While the anomalous values of Hydrogen were usually in a form of a single peak that corresponded with 141 meter sampling point. Only a few times were values for Hydrogen higher than 100 ppm and detected at most of the sampling points, usually only one or two points resulted with small values near the 141 meter sampling point. Based on the radon values alone, we would have to conclude that the fault probably lies near or between the 116 and 141 meter sampling points, but with the additional data of the CO 2 and H 2 soil-gases one could say that the fault is probably near the 141 meter sampling point. Thus, we have

  18. Microseismic event location by master-event waveform stacking

    Science.gov (United States)

    Grigoli, F.; Cesca, S.; Dahm, T.

    2016-12-01

    Waveform stacking location methods are nowadays extensively used to monitor induced seismicity monitoring assoiciated with several underground industrial activities such as Mining, Oil&Gas production and Geothermal energy exploitation. In the last decade a significant effort has been spent to develop or improve methodologies able to perform automated seismological analysis for weak events at a local scale. This effort was accompanied by the improvement of monitoring systems, resulting in an increasing number of large microseismicity catalogs. The analysis of microseismicity is challenging, because of the large number of recorded events often characterized by a low signal-to-noise ratio. A significant limitation of the traditional location approaches is that automated picking is often done on each seismogram individually, making little or no use of the coherency information between stations. In order to improve the performance of the traditional location methods, in the last year, alternative approaches have been proposed. These methods exploits the coherence of the waveforms recorded at different stations and do not require any automated picking procedure. The main advantage of this methods relies on their robustness even when the recorded waveforms are very noisy. On the other hand, like any other location method, the location performance strongly depends on the accuracy of the available velocity model. When dealing with inaccurate velocity models, in fact, location results can be affected by large errors. Here we will introduce a new automated waveform stacking location method which is less dependent on the knowledge of the velocity model and presents several benefits, which improve the location accuracy: 1) it accounts for phase delays due to local site effects, e.g. surface topography or variable sediment thickness 2) theoretical velocity model are only used to estimate travel times within the source volume, and not along the whole source-sensor path. We

  19. Assessment of long-term gas sampling design at two commercial manure-belt layer barns.

    Science.gov (United States)

    Chai, Li-Long; Ni, Ji-Qin; Chen, Yan; Diehl, Claude A; Heber, Albert J; Lim, Teng T

    2010-06-01

    Understanding temporal and spatial variations of aerial pollutant concentrations is important for designing air quality monitoring systems. In long-term and continuous air quality monitoring in large livestock and poultry barns, these systems usually use location-shared analyzers and sensors and can only sample air at limited number of locations. To assess the validity of the gas sampling design at a commercial layer farm, a new methodology was developed to map pollutant gas concentrations using portable sensors under steady-state or quasi-steady-state barn conditions. Three assessment tests were conducted from December 2008 to February 2009 in two manure-belt layer barns. Each barn was 140.2 m long and 19.5 m wide and had 250,000 birds. Each test included four measurements of ammonia and carbon dioxide concentrations at 20 locations that covered all operating fans, including six of the fans used in the long-term sampling that represented three zones along the lengths of the barns, to generate data for complete-barn monitoring. To simulate the long-term monitoring, gas concentrations from the six long-term sampling locations were extracted from the 20 assessment locations. Statistical analyses were performed to test the variances (F-test) and sample means (t test) between the 6- and 20-sample data. The study clearly demonstrated ammonia and carbon dioxide concentration gradients that were characterized by increasing concentrations from the west to east ends of the barns following the under-cage manure-belt travel direction. Mean concentrations increased from 7.1 to 47.7 parts per million (ppm) for ammonia and from 2303 to 3454 ppm for carbon dioxide from the west to east of the barns. Variations of mean gas concentrations were much less apparent between the south and north sides of the barns, because they were 21.2 and 20.9 ppm for ammonia and 2979 and 2951 ppm for carbon dioxide, respectively. The null hypotheses that the variances and means between the 6- and 20

  20. Quantitative analytical hierarchy process to marketing store location selection

    Directory of Open Access Journals (Sweden)

    Harwati

    2018-01-01

    Full Text Available The selection of Store to market the product is belong to Multi Criteria Decision Making problem. The criteria used have conflict of interest with each other to produce an optimal location. This research uses four important criteria to select new location of marketing store appropriate with the references: distance to location, competition level with competitor, number of potential customer, and location rent cost. Quantitative data is used to determine the optimum location with AHP method. Quantitative data are preferred to avoid inconsistency when using expert opinion. The AHP result optimum location among three alternatives places.

  1. Environmental sampling accounting at the Savannah River Plant

    International Nuclear Information System (INIS)

    Zeigler, C.C.; Wood, M.B.

    1978-06-01

    At the Savannah River Plant Environmental Monitoring Laboratories, a computer-based systematic accounting method was developed to ensure that all scheduled samples are collected, processed through the laboratory, and counted without delay. The system employs an IBM 360/195 computer with a magnetic tape master file, an on-line disk file, and cathode ray tube (CRT) terminals. Scheduling and accounting are accomplished by using computer-generated schedules, collection labels, and output/input cards. For each scheduled sample and analysis, a printed card is issued for collection, laboratory analysis, and counting. The cards also contain information needed by personnel performing the jobs, such as sample location, aliquot to be processed, or procedure number. Manual entries are made on the cards when each step in the process is completed. Additional pertinent data are also manually entered on the cards; e.g., entries are made explaining why a sample is not collected, the sample aliquot in the event a nonstandard aliquot is processed, field measurement results, and analytical results. These manually entered data are keypunched and read into the computer files. The computer files are audited daily, and summaries of samples not processed in pre-established normal time intervals are issued. The progress of sample analyses can also be readily determined at any time using the CRT terminal. Historic data are also maintained on magnetic tape and workload summaries are issued showing the number of samples and number of determinations per month

  2. Location-based prospective memory.

    Science.gov (United States)

    O'Rear, Andrea E; Radvansky, Gabriel A

    2018-02-01

    This study explores location-based prospective memory. People often have to remember to do things when in a particular location, such as buying tissues the next time they are in the supermarket. For event cognition theory, location is important for structuring events. However, because event cognition has not been used to examine prospective memory, the question remains of how multiple events will influence prospective memory performance. In our experiments, people delivered messages from store to store in a virtual shopping mall as an ongoing task. The prospective tasks were to do certain activities in certain stores. For Experiment 1, each trial involved one prospective memory task to be done in a single location at one of three delays. The virtual environment and location cues were effective for prospective memory, and performance was unaffected by delay. For Experiment 2, each trial involved two prospective memory tasks, given in either one or two instruction locations, and to be done in either one or two store locations. There was improved performance when people received instructions from two locations and did both tasks in one location relative to other combinations. This demonstrates that location-based event structure influences how well people perform on prospective memory tasks.

  3. Stratified sampling design based on data mining.

    Science.gov (United States)

    Kim, Yeonkook J; Oh, Yoonhwan; Park, Sunghoon; Cho, Sungzoon; Park, Hayoung

    2013-09-01

    To explore classification rules based on data mining methodologies which are to be used in defining strata in stratified sampling of healthcare providers with improved sampling efficiency. We performed k-means clustering to group providers with similar characteristics, then, constructed decision trees on cluster labels to generate stratification rules. We assessed the variance explained by the stratification proposed in this study and by conventional stratification to evaluate the performance of the sampling design. We constructed a study database from health insurance claims data and providers' profile data made available to this study by the Health Insurance Review and Assessment Service of South Korea, and population data from Statistics Korea. From our database, we used the data for single specialty clinics or hospitals in two specialties, general surgery and ophthalmology, for the year 2011 in this study. Data mining resulted in five strata in general surgery with two stratification variables, the number of inpatients per specialist and population density of provider location, and five strata in ophthalmology with two stratification variables, the number of inpatients per specialist and number of beds. The percentages of variance in annual changes in the productivity of specialists explained by the stratification in general surgery and ophthalmology were 22% and 8%, respectively, whereas conventional stratification by the type of provider location and number of beds explained 2% and 0.2% of variance, respectively. This study demonstrated that data mining methods can be used in designing efficient stratified sampling with variables readily available to the insurer and government; it offers an alternative to the existing stratification method that is widely used in healthcare provider surveys in South Korea.

  4. RECOMMENDATIONS FOR SAMPLING OF TANK 19 IN F TANK FARM

    Energy Technology Data Exchange (ETDEWEB)

    Harris, S.; Shine, G.

    2009-12-14

    is needed and can be achieved by the addition of the archived samples, they will be analyzed and included in the statistical computations. Initially the analyte concentrations in the residual material on the floor of Tank 19 will be determined separately in the North and the South hemispheres. However, if final sampling results show that differences between the North and South samples are consistent within sampling variation, then the final computations can be based on consolidating all sample results from the tank floor. Recommended locations may be subject to physical tank access and sampling constraints for the additional samples. The recommendations have been discussed in Section 4 and are based on partitioning the Tank 19 floor into an inner and an outer ring and six 60{sup o} sectors depicted in Figure 1. The location of the border between the inner and outer rings is based on dividing the residual material into two approximately equal volumes.

  5. About condition of soil ground at locations of the former Azgir nuclear test site

    International Nuclear Information System (INIS)

    Akhmetov, E.Z.; Adymov, Zh.I.; Ermatov, A.S.

    2003-01-01

    Full text: Soil condition after underground nuclear explosions at locations of the test sites is considered. The region is situated in the zone of northern deserts and characterized by prevalence of greyish-brown soils in conditions of sharply continental climate and presence of salt in soil-formative complex including tertiary clays, loess-like loam, loam sands and sands. There are small quantity of humus in such soil. During investigation of soil characteristics and ability of soil particles to form conglomerates, possessing of different properties, it is necessary to know both element and phase composition, determining, in the most extent, such physical and mechanical macro-characteristics as: density, stickiness, air and water penetrability, solubility, chemical resistance, granulometric set and others. Phase composition of soil samples can be, to a sufficient extent, determined by the X-ray diffractometry methods using ordinary X-ray experimental facilities. Phase composition of soil includes gypsum, quartz, calcium, potash feldspar hematite, kaolin, peach and mica in different quantities. Data on element composition of soil samples were obtained from the territory of technological locations of test site using the method of X-ray-fluorescent analysis. Granulometric composition of soil ground has been investigated using the methods of dry sieving and wet sieving for determination of radionuclide distribution in different fractions of soil particles. By the method of the dry sieving of soil ground samples there are taken place a sticking the small together of fine fractions and an adhesion of stuck-together particles to more large ones. Therefore, fine fractions cannot be separate completely at dry sieving. As distinct from the dry sieving an use of water jet in the sieving allows to overcome defects of the dry method and, by a sufficiently effective separation of granulometric fractions, to obtain more precise results of investigations of granulometric

  6. Influence of motivation, library materials and location on use of ...

    African Journals Online (AJOL)

    The study investigated the influence of motivation, availability and adequacy of library materials as well as location of library on the use of library by undergraduates in University of Ibadan, Nigeria. The convenience sampling technique was adopted to select only 150 undergraduates while the questionnaire was used as the ...

  7. Guidance for air sampling at nuclear facilities

    International Nuclear Information System (INIS)

    Breslin, A.J.

    1976-11-01

    The principal uses of air sampling at nuclear facilities are to monitor general levels of radioactive air contamination, identify sources of air contamination, and evaluate the effectiveness of contaminant control equipment, determine exposures of individual workers, and provide automatic warning of hazardous concentrations of radioactivity. These applications of air sampling are discussed with respect to standards of occupational exposure, instrumentation, sample analysis, sampling protocol, and statistical treatment of concentration data. Emphasis is given to the influence of spacial and temporal variations of radionuclide concentration on the location, duration, and frequency of air sampling

  8. Using ArcMap, Google Earth, and Global Positioning Systems to select and locate random households in rural Haiti

    Directory of Open Access Journals (Sweden)

    Wampler Peter J

    2013-01-01

    Full Text Available Abstract Background A remote sensing technique was developed which combines a Geographic Information System (GIS; Google Earth, and Microsoft Excel to identify home locations for a random sample of households in rural Haiti. The method was used to select homes for ethnographic and water quality research in a region of rural Haiti located within 9 km of a local hospital and source of health education in Deschapelles, Haiti. The technique does not require access to governmental records or ground based surveys to collect household location data and can be performed in a rapid, cost-effective manner. Methods The random selection of households and the location of these households during field surveys were accomplished using GIS, Google Earth, Microsoft Excel, and handheld Garmin GPSmap 76CSx GPS units. Homes were identified and mapped in Google Earth, exported to ArcMap 10.0, and a random list of homes was generated using Microsoft Excel which was then loaded onto handheld GPS units for field location. The development and use of a remote sensing method was essential to the selection and location of random households. Results A total of 537 homes initially were mapped and a randomized subset of 96 was identified as potential survey locations. Over 96% of the homes mapped using Google Earth imagery were correctly identified as occupied dwellings. Only 3.6% of the occupants of mapped homes visited declined to be interviewed. 16.4% of the homes visited were not occupied at the time of the visit due to work away from the home or market days. A total of 55 households were located using this method during the 10 days of fieldwork in May and June of 2012. Conclusions The method used to generate and field locate random homes for surveys and water sampling was an effective means of selecting random households in a rural environment lacking geolocation infrastructure. The success rate for locating households using a handheld GPS was excellent and only

  9. Vapor space characterization of waste Tank 241-BY-108: Results from samples collected on 10/27/94

    International Nuclear Information System (INIS)

    McVeety, B.D.; Clauss, T.W.; Ligotke, M.W.

    1995-10-01

    This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-BY-108 (referred to as Tank BY-108). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH 3 ), nitrogen dioxide (NO 2 ), nitric oxide (NO), and water vapor (H 2 O). Trends in NH 3 and H 2 O samples indicated a possible sampling problem. Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO x ) was not requested. In addition, the authors looked for the 40 TO-14 compounds plus an additional 15 analytes. Of these, 17 were observed above the 5-ppbv reporting cutoff. Also, eighty-one organic tentatively identified compounds (TICs) were observed above the reporting cutoff (ca.) 10 ppbv, and are reported with concentrations that are semiquantitative estimates based on internal standard response factors. The nine organic analytes with the highest estimated concentrations are listed in Summary Table 1 and account for approximately 48% of the total organic components in the headspace of Tank BY-108. Three permanent gases, hydrogen (H 2 ), carbon dioxide (CO 2 ), and nitrous oxide (N 2 O) were also detected. Tank BY-108 is on the Ferrocyanide Watch List

  10. Results Of Analytical Sample Crosschecks For Next Generation Solvent Extraction Samples Isopar L Concentration And pH

    International Nuclear Information System (INIS)

    Peters, T.; Fink, S.

    2011-01-01

    As part of the implementation process for the Next Generation Cesium Extraction Solvent (NGCS), SRNL and F/H Lab performed a series of analytical cross-checks to ensure that the components in the NGCS solvent system do not constitute an undue analytical challenge. For measurement of entrained Isopar(reg s ign) L in aqueous solutions, both labs performed similarly with results more reliable at higher concentrations (near 50 mg/L). Low bias occurred in both labs, as seen previously for comparable blind studies for the baseline solvent system. SRNL recommends consideration to use of Teflon(trademark) caps on all sample containers used for this purpose. For pH measurements, the labs showed reasonable agreement but considerable positive bias for dilute boric acid solutions. SRNL recommends consideration of using an alternate analytical method for qualification of boric acid concentrations.

  11. Stream sediment sampling and analysis. Final report

    International Nuclear Information System (INIS)

    Means, J.L.; Voris, P.V.; Headington, G.L.

    1986-04-01

    The objectives were to sample and analyze sediments from upstream and downstream locations (relative to the Goodyear Atomic plant site) of three streams for selected pollutants. The three streams sampled were the Scioto River, Big Beaver Creek, and Big Run Creek. Sediment samples were analyzed for EPA's 129 priority pollutants (Clean Water Act) as well as isotopic uranium ( 234 U, 235 U, and 238 U) and technetium-99

  12. Forensic Comparison of Soil Samples Using Nondestructive Elemental Analysis.

    Science.gov (United States)

    Uitdehaag, Stefan; Wiarda, Wim; Donders, Timme; Kuiper, Irene

    2017-07-01

    Soil can play an important role in forensic cases in linking suspects or objects to a crime scene by comparing samples from the crime scene with samples derived from items. This study uses an adapted ED-XRF analysis (sieving instead of grinding to prevent destruction of microfossils) to produce elemental composition data of 20 elements. Different data processing techniques and statistical distances were evaluated using data from 50 samples and the log-LR cost (C llr ). The best performing combination, Canberra distance, relative data, and square root values, is used to construct a discriminative model. Examples of the spatial resolution of the method in crime scenes are shown for three locations, and sampling strategy is discussed. Twelve test cases were analyzed, and results showed that the method is applicable. The study shows how the combination of an analysis technique, a database, and a discriminative model can be used to compare multiple soil samples quickly. © 2016 American Academy of Forensic Sciences.

  13. Vapor space characterization of waste tank 241-BY-105 (in situ): Results from samples collected on May 9, 1994

    International Nuclear Information System (INIS)

    McVeety, B.D.; Pool, K.H.; Ligotke, M.W.; Clauss, T.W.; Lucke, R.B.; Sharma, A.K.; McCulloch, M.; Fruchter, J.S.; Goheen, S.C.

    1995-05-01

    This report describes inorganic and organic analyses results from in situ samples obtained from the tank headspace of the Hanford waste storage Tank 241-BY-105 (referred to as Tank BY-105). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds NH 3 , NO 2 , NO, HCN, and H 2 O. Sampling for sulfur oxides was not requested. Results of the inorganic samples were affected by sampling errors that led to an undefined uncertainty in sample volume. Consequently, tank-headspace concentrations are estimated only. Thirty-nine tentatively identified organic analytes were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and their quantitation is beyond the scope of this study. In addition, we looked for the 41 standard TO-14 analytes. Of these, only a few were observed above the 2-ppbv detection limit. The 16 organic analytes with the highest estimated concentrations are listed. These 16 analytes account for approximately 68% of the total or organic components in Tank BY-105

  14. Headspace vapor characterization of Hanford Waste Tank 241-U-112: Results from samples collected on 7/09/96

    International Nuclear Information System (INIS)

    Evans, J.C.; Pool, K.H.; Thomas, B.L.; Olsen, K.B.; Fruchter, J.S.; Silvers, K.L.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-U-112 at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company

  15. Long-term frozen storage of urine samples: a trouble to get PCR results in Schistosoma spp. DNA detection?

    Directory of Open Access Journals (Sweden)

    Pedro Fernández-Soto

    Full Text Available BACKGROUND: Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples' storage or conditions for handling and DNA preservation and extraction methods. METHODOLOGY/PRINCIPAL FINDINGS: We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patients urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template. CONCLUSIONS/SIGNIFICANCE: Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA

  16. Perceptions of clients on awareness and the geographical location of a South African university sexual health clinic.

    Science.gov (United States)

    Adams, Rukshana; Van Der Heever, Mariana M; Damons, Anneleen

    2017-09-27

    The Campus Health Service at Stellenbosch University has a sub-division, a sexual health clinic, which provides sexual health services. The clients of the sexual health clinic consist of staff members and students. This article reports on the perceptions of clients that relate to awareness and the geographical location of the clinic. The Campus Health Service at Stellenbosch University's main campus. A descriptive qualitative approach was applied utilising in-depth interviews. A sample of n = 15 was drawn through purposive sampling and data saturation was achieved with the sample. The following themes emerged from the data: location of the clinic, awareness of sexual health services and marketing and advertising. The findings of the study revealed that accessibility of the clinic is influenced by the geographical location of the clinic and that marketing and awareness of services require attention.

  17. Effect of sample stratification on dairy GWAS results

    Directory of Open Access Journals (Sweden)

    Ma Li

    2012-10-01

    Full Text Available Abstract Background Artificial insemination and genetic selection are major factors contributing to population stratification in dairy cattle. In this study, we analyzed the effect of sample stratification and the effect of stratification correction on results of a dairy genome-wide association study (GWAS. Three methods for stratification correction were used: the efficient mixed-model association expedited (EMMAX method accounting for correlation among all individuals, a generalized least squares (GLS method based on half-sib intraclass correlation, and a principal component analysis (PCA approach. Results Historical pedigree data revealed that the 1,654 contemporary cows in the GWAS were all related when traced through approximately 10–15 generations of ancestors. Genome and phenotype stratifications had a striking overlap with the half-sib structure. A large elite half-sib family of cows contributed to the detection of favorable alleles that had low frequencies in the general population and high frequencies in the elite cows and contributed to the detection of X chromosome effects. All three methods for stratification correction reduced the number of significant effects. EMMAX method had the most severe reduction in the number of significant effects, and the PCA method using 20 principal components and GLS had similar significance levels. Removal of the elite cows from the analysis without using stratification correction removed many effects that were also removed by the three methods for stratification correction, indicating that stratification correction could have removed some true effects due to the elite cows. SNP effects with good consensus between different methods and effect size distributions from USDA’s Holstein genomic evaluation included the DGAT1-NIBP region of BTA14 for production traits, a SNP 45kb upstream from PIGY on BTA6 and two SNPs in NIBP on BTA14 for protein percentage. However, most of these consensus effects had

  18. Headspace vapor characterization of Hanford waste Tank 241-C-201: Results from samples collected on 06/19/96

    International Nuclear Information System (INIS)

    Thomas, B.L.; Evans, J.C.; Pool, K.H.; Olsen, K.B.; Fruchter, J.S.; Silvers, K.L.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-C-201 (Tank C-201) at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, on sample volumes provided by WHC. A summary, of the inorganic analytes, permanent gases, and total non-methane organic compounds is listed in a table. Detailed descriptions of the analytical results appear in the appendices

  19. Co-location synergies : specialized versus diverse logistics concentration areas

    OpenAIRE

    Heuvel, van den, F.P.; Langen, de, P.W.; Donselaar, van, K.H.; Fransoo, J.C.

    2012-01-01

    Purpose: The purpose of this paper is to contribute to the understanding of spatial concentration of logistics firms by empirically analyzing synergies through co-location and investigating whether co-location of logistics establishments in specialized logistics concentration areas results in benefits compared to co-location in diverse logistics concentration areas. Methodology: A survey among managers of 128 logistics establishments located in logistics concentration areas was used to test f...

  20. Sample size estimation and sampling techniques for selecting a representative sample

    Directory of Open Access Journals (Sweden)

    Aamir Omair

    2014-01-01

    Full Text Available Introduction: The purpose of this article is to provide a general understanding of the concepts of sampling as applied to health-related research. Sample Size Estimation: It is important to select a representative sample in quantitative research in order to be able to generalize the results to the target population. The sample should be of the required sample size and must be selected using an appropriate probability sampling technique. There are many hidden biases which can adversely affect the outcome of the study. Important factors to consider for estimating the sample size include the size of the study population, confidence level, expected proportion of the outcome variable (for categorical variables/standard deviation of the outcome variable (for numerical variables, and the required precision (margin of accuracy from the study. The more the precision required, the greater is the required sample size. Sampling Techniques: The probability sampling techniques applied for health related research include simple random sampling, systematic random sampling, stratified random sampling, cluster sampling, and multistage sampling. These are more recommended than the nonprobability sampling techniques, because the results of the study can be generalized to the target population.

  1. Data Validation Package May 2016 Groundwater Sampling at the Lakeview, Oregon, Processing Site August 2016

    Energy Technology Data Exchange (ETDEWEB)

    Linard, Joshua [USDOE Office of Legacy Management, Washington, DC (United States); Hall, Steve [Navarro Research and Engineering, Inc., Oak Ridge, TN (United States)

    2016-08-01

    This biennial event includes sampling five groundwater locations (four monitoring wells and one domestic well) at the Lakeview, Oregon, Processing Site. For this event, the domestic well (location 0543) could not be sampled because no one was in residence during the sampling event (Note: notification was provided to the resident prior to the event). Per Appendix A of the Groundwater Compliance Action Plan, sampling is conducted to monitor groundwater quality on a voluntary basis. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). One duplicate sample was collected from location 0505. Water levels were measured at each sampled monitoring well. The constituents monitored at the Lakeview site are manganese and sulfate. Monitoring locations that exceeded the U.S. Environmental Protection Agency (EPA) Secondary Maximum Contaminant Levels for these constituents are listed in Table 1. Review of time-concentration graphs included in this report indicate that manganese and sulfate concentrations are consistent with historical measurements.

  2. The results of experimental studies of VLF-ULF electromagnetic emission by rock samples due to mechanical action

    Science.gov (United States)

    Panfilov, A. A.

    2014-06-01

    The paper presents the results of laboratory experiments on electromagnetic emissions excitation (the electric component of electromagnetic fields) by rock samples due to different forms of mechanical stress applications. It was shown that samples generate electric impulses with different spectra when the impact action, gradual loading or dynamic friction is applied. It was ascertained that level and spectral compositions of signals, generated by rock samples, change with an increasing number of hits. It was found that strong electromagnetic signals, generated while rock samples were fracturing, were accompanied by repetitive weak but perceptible variations in the electric field intensity in short frequency ranges.

  3. Parameter sampling capabilities of sequential and simultaneous data assimilation: II. Statistical analysis of numerical results

    International Nuclear Information System (INIS)

    Fossum, Kristian; Mannseth, Trond

    2014-01-01

    We assess and compare parameter sampling capabilities of one sequential and one simultaneous Bayesian, ensemble-based, joint state-parameter (JS) estimation method. In the companion paper, part I (Fossum and Mannseth 2014 Inverse Problems 30 114002), analytical investigations lead us to propose three claims, essentially stating that the sequential method can be expected to outperform the simultaneous method for weakly nonlinear forward models. Here, we assess the reliability and robustness of these claims through statistical analysis of results from a range of numerical experiments. Samples generated by the two approximate JS methods are compared to samples from the posterior distribution generated by a Markov chain Monte Carlo method, using four approximate measures of distance between probability distributions. Forward-model nonlinearity is assessed from a stochastic nonlinearity measure allowing for sufficiently large model dimensions. Both toy models (with low computational complexity, and where the nonlinearity is fairly easy to control) and two-phase porous-media flow models (corresponding to down-scaled versions of problems to which the JS methods have been frequently applied recently) are considered in the numerical experiments. Results from the statistical analysis show strong support of all three claims stated in part I. (paper)

  4. Does Drinking Location Matter? Profiles of Risky Single-Occasion Drinking by Location and Alcohol-Related Harm among Young Men.

    Science.gov (United States)

    Bähler, Caroline; Dey, Michelle; Dermota, Petra; Foster, Simon; Gmel, Gerhard; Mohler-Kuo, Meichun

    2014-01-01

    In adolescents and young adults, acute consequences like injuries account for a substantial proportion of alcohol-related harm, especially in risky single-occasion (RSO) drinkers. The primary aim of the study was to characterize different drinking profiles in RSO drinkers according to drinking locations and their relationship to negative, alcohol-related consequences. The sample consisted of 2746 young men from the Cohort Study on Substance Use Risk Factors who had reported drinking six or more drinks on a single-occasion at least monthly over the preceding 12 months. Principal component analysis on the frequency and amount of drinking at 11 different locations was conducted, and 2 distinguishable components emerged: a non-party-dimension (loading high on theater/cinema, sport clubs, other clubs/societies, restaurants, and sport events) and a party-dimension (loading high on someone else's home, pubs/bars, discos/nightclubs, outdoor public places, special events, and home). Differential impacts of drinking location profiles were observed on severe negative alcohol-related consequences (SAC). Relative to those classified as low or intermediate in both dimensions, no significant difference experiencing SAC was found among those who were classified as high in the non-party-dimension only. However, those who were classified as high in the party-dimension alone or in both dimensions were more likely to experience SAC. These differential effects remained after adjusting for alcohol consumption (volume and risky single-occasion drinking), personality traits, and peer-influence [adjusted OR = 0.83 (0.68-1.02), 1.57 (1.27-1.96), and 1.72 (1.23-2.41), respectively], indicating independent effects of drinking location on SAC. The inclusion of sociodemographic factors did not alter this association. The fact that this cluster of party-dimension locations seems to predispose young men to experiencing SAC has important implications for alcohol control policies.

  5. Does drinking location matter? Profiles of risky single-occasion drinking by location and alcohol-related harm among young men

    Directory of Open Access Journals (Sweden)

    Caroline eBähler

    2014-06-01

    Full Text Available In adolescents and young adults, acute consequences like injuries account for a substantial proportion of alcohol-related harm, especially in risky single-occasion (RSO drinkers. The primary aim of the study was to characterize different drinking profiles in RSO drinkers according to drinking locations and their relationship to negative, alcohol-related consequences. The sample consisted of 2746 young men from the Cohort Study on Substance Use Risk Factors (C-SURF who had reported drinking 6 or more drinks on a single occasion at least monthly over the preceding 12 months. Principal component analysis on the frequency and amount of drinking at 11 different locations was conducted, and two distinguishable components emerged: a non-party-dimension (loading high on theatre/cinema, sport clubs, other clubs/societies, restaurants, and sport events and a party-dimension (loading high on someone else’s home, pubs/bars, discos/nightclubs, outdoor public places, special events, and home. Differential impacts of drinking location profiles were observed on severe negative alcohol-related consequences (SAC. Relative to those classified as low or intermediate in both dimensions, no significant difference experiencing SAC was found among those who were classified as high in the non-party-dimension only. However, those who were classified as high in the party-dimension alone or in both dimensions were more likely to experience SAC. These differential effects remained after adjusting for alcohol consumption (volume and RSOD, personality traits, and peer-influence (adjusted OR=0.83 [0.68-1.02], 1.57 [1.27-1.96] and 1.72 [1.23-2.41], respectively, indicating independent effects of drinking location on SAC. The inclusion of sociodemographic factors did not alter this association. The fact that this cluster of party-dimension locations seems to predispose young men to experiencing SAC has important implications for alcohol control policies.

  6. Characterization of Vadose Zone Sediment: Uncontaminated RCRA Borehole Core Samples and Composite Samples

    International Nuclear Information System (INIS)

    Serne, R. Jeffrey; Bjornstad, Bruce N.; Schaef, Herbert T.; Williams, Bruce A.; Lanigan, David C.; Horton, Duane G.; Clayton, Ray E.; Mitroshkov, Alexandre V.; Legore, Virginia L.; O'Hara, Matthew J.; Brown, Christopher F.; Parker, Kent E.; Kutnyakov, Igor V.; Serne, Jennifer N.; Last, George V.; Smith, Steven C.; Lindenmeier, Clark W.; Zachara, John M.; Burke, Deborah Sd.

    2001-01-01

    The overall goal of the of the Tank Farm Vadose Zone Project, led by CH2M HILL Hanford Group, Inc., is to define risks from past and future single-shell tank farm activities. To meet this goal, CH2M HILL Hanford Group, Inc. asked scientists from Pacific Northwest National Laboratory to perform detailed analyses on vadose zone sediment from within the S-SX Waste Management Area. This report is the first in a series of four reports to present the results of these analyses. Specifically, this report contains all the geologic, geochemical, and selected physical characterization data collected on vadose zone sediment recovered from RCRA borehole bore samples and composite samples. Intact cores from two RCRA boreholes (299-W22-48 and 299-W22-50) near the SX Tank Farm and four, large-quantity grab samples from outcrop sediment on and off the Hanford Site were sampled to better understand the fate of contaminants in the vadose zone beneath underground storage tanks at the Hanford Site. Borehole and outcrop samples analyzed for this report are located outside the tank farms, and therefore may be considered standard or background samples from which to compare contaminated sediments within the tank farms themselves. This report presents our interpretation of the physical, chemical, and mineralogical properties of the uncontaminated vadose zone sediments, and variations in the vertical distribution of these properties. The information presented in this report is intended to support preparation of the S-SX Field Investigation Report to be prepared by CH2M Hill Hanford Group, Inc. as well as future remediation actions at the S-SX Tank Farm

  7. Detection of a Yersinia pestis gene homologue in rodent samples

    Directory of Open Access Journals (Sweden)

    Timothy A. Giles

    2016-08-01

    Full Text Available A homologue to a widely used genetic marker, pla, for Yersinia pestis has been identified in tissue samples of two species of rat (Rattus rattus and Rattus norvegicus and of mice (Mus musculus and Apodemus sylvaticus using a microarray based platform to screen for zoonotic pathogens of interest. Samples were from urban locations in the UK (Liverpool and Canada (Vancouver. The results indicate the presence of an unknown bacterium that shares a homologue for the pla gene of Yersinia pestis, so caution should be taken when using this gene as a diagnostic marker.

  8. Automatic gamma radiation scanning device and feed mechanism for plural sample holders

    International Nuclear Information System (INIS)

    Byrd, W.J.

    1976-01-01

    Apparatus is disclosed for measuring the level of gamma radiation contained in a plurality of biological samples which are located on the fibrous sheet member carried by a sample holder. The apparatus is adapted to count the radiation level of the number of closely spaced samples located in rows and columns on the sheet by automatically sequencing through the individual samples within the rows and to advance the holder to bring successive rows into proximity with the detector. The detector is moved from sample to sample within the rows, although a number of detectors can be employed. A plurality of sample holders are automatically advanced to the detector. 25 claims, 5 drawing figures

  9. TMI-2 core debris grab samples: Examination and analysis: Part 1

    International Nuclear Information System (INIS)

    Akers, D.W.; Carlson, E.R.; Cook, B.A.; Ploger, S.A.; Carlson, J.O.

    1986-09-01

    Six samples of particulate debris were removed from the TMI-2 core rubble bed during September and October 1983, and five more samples were obtained in March 1984. The samples (up to 174 g each) were obtained at two locations in the core: H8 (center) and E9 (mid-radius). Ten of the eleven samples were examined at the Idaho National Engineering Laboratory to obtain data on the physical and chemical nature of the debris and the postaccident condition of the core. Portions of the samples also were subjected to differential thermal analysis at Rockwell Hanford Operations and metallurgical and chemical examinations at Argonne National Laboratories. This report presents results of the examination of the core debris grab samples, including physical, metallurgical, chemical, and radiochemical analyses. The results indicate that temperatures in the core reached at least 3100 K during the TMI-2 accident, fuel melting and significant mixing of core structural material occurred, and large fractions of some radionuclides (e.g., 90 Sr and 144 Ce) were retained in the core

  10. Barium carbonate sediment sampling for inorganic dissolved carbon using isotope mass ratio spectrometer

    International Nuclear Information System (INIS)

    Kamaruzaman Mohamad; Rohaimah Demanah; Juhari Mohd Yusof; Roslanzairi Mostapa

    2009-01-01

    This paperwork explain the method of water sampling to obtain the precipitate of BaCO 3 solutions that will be used to analyze 13 C from field work in Kelana Jaya, Selangor, Langkawi, Kedah and Taiping, Perak. The sampling involves collecting of water samples for groundwater from boreholes and surface water from canal, river, pond and ex-mining pond from several locations at the study sites. This study also elaborates the instruments and chemicals used. The main purpose of this sampling is to obtain the precipitate of BaCO 3 for 13 C analysis of dissolved inorganic carbon (DIC). A correct sampling method according to standard is very important to ensure an accurate and precise result. With this, the data from the laboratory analysis result can be fully utilized to make the interpretation of the pollutants movement. (Author)

  11. Determination of naturally occurring radionuclides in soil samples of Ayranci, Turkey

    Science.gov (United States)

    Agar, Osman; Eke, Canel; Boztosun, Ismail; Emin Korkmaz, M.

    2015-04-01

    The specific activity, radiation hazard index and the annual effective dose of the naturally occurring radioactive elements (238U, 232Th and 40K) were determined in soil samples collected from 12 different locations in Ayranci region by using a NaI(Tl) gamma-ray spectrometer. The measured activity concentrations of the natural radionuclides in studied soil samples were compared with the corresponding results of different countries and the internationally reported values. From the analysis, it is found that these materials may be safely used as construction materials and do not pose significant radiation hazards.

  12. 222Rn in water: A comparison of two sample collection methods and two sample transport methods, and the determination of temporal variation in North Carolina ground water

    International Nuclear Information System (INIS)

    Hightower, J.H. III

    1994-01-01

    Objectives of this field experiment were: (1) determine whether there was a statistically significant difference between the radon concentrations of samples collected by EPA's standard method, using a syringe, and an alternative, slow-flow method; (2) determine whether there was a statistically significant difference between the measured radon concentrations of samples mailed vs samples not mailed; and (3) determine whether there was a temporal variation of water radon concentration over a 7-month period. The field experiment was conducted at 9 sites, 5 private wells, and 4 public wells, at various locations in North Carolina. Results showed that a syringe is not necessary for sample collection, there was generally no significant radon loss due to mailing samples, and there was statistically significant evidence of temporal variations in water radon concentrations

  13. Internet Geo-Location

    Science.gov (United States)

    2017-12-01

    INTERNET GEO-LOCATION DUKE UNIVERSITY DECEMBER 2017 FINAL TECHNICAL REPORT APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED STINFO COPY AIR...REPORT TYPE FINAL TECHNICAL REPORT 3. DATES COVERED (From - To) MAY 2014 – MAY 2017 4. TITLE AND SUBTITLE INTERNET GEO-LOCATION 5a. CONTRACT...of SpeedTest servers that are used by end users to measure the speed of their Internet connection. The servers log the IP address and the location

  14. Optimal Locations for Siting Wind Energy Projects: Technical Challenges, Economics, and Public Preferences

    Science.gov (United States)

    Lamy, Julian V.

    40 TWh of new wind generation in the Midwestern transmission system (MISO) while minimizing system costs. Results show that building wind farms in North/South Dakota (windiest states) compared to Illinois (less windy, but close to population centers) would only be economical if the incremental transmission costs to access them were below 360/kW of wind capacity (break-even value). Historically, the incremental transmission costs for wind development in North/South Dakota compared to in Illinois are about twice this value. However, the break-even incremental transmission cost for wind farms in Minnesota/Iowa (also windy states) is 250/kW, which is consistent with historical costs. I conclude that for the case in MISO, building wind projects in more distant locations (i.e., Minnesota/Iowa) is most economical. My two final chapters use semi-structured interviews (Chapter 4) and conjoint-based surveys (Chapter 5) to understand public perceptions and preferences for different wind project siting characteristics such as the distance between the project and a person's home (i.e., "not-in-my-backyard" or NIMBY) and offshore vs. onshore locations. The semi-structured interviews, conducted with members of a community in Massachusetts, revealed that economic benefit to the community is the most important factor driving perceptions about projects, along with aesthetics, noise impacts, environmental benefits, hazard to wildlife, and safety concerns. In Chapter 5, I show the results from the conjoint survey. The study's sample included participants from a coastal community in Massachusetts and a U.S.-wide sample from Amazon's Mechanical Turk. Results show that participants in the U.S.-wide sample perceived a small reduction in utility, equivalent to $1 per month, for living within 1 mile of a project. Surprisingly, I find no evidence of this effect for participants in the coastal community. The most important characteristic to both samples was the economic benefits from the

  15. UMTRA project water sampling and analysis plan, Gunnison, Colorado

    International Nuclear Information System (INIS)

    1994-06-01

    This water sampling and analysis plan summarizes the results of previous water sampling activities and the plan for water sampling activities for calendar year 1994. A buffer zone monitoring plan is included as an appendix. The buffer zone monitoring plan is designed to protect the public from residual contamination that entered the ground water as a result of former milling operations. Surface remedial action at the Gunnison Uranium Mill Tailings Remedial Action Project site began in 1992; completion is expected in 1995. Ground water and surface water will be sampled semiannually in 1994 at the Gunnison processing site (GUN-01) and disposal site (GUN-08). Results of previous water sampling at the Gunnison processing site indicate that ground water in the alluvium is contaminated by the former uranium processing activities. Background ground water conditions have been established in the uppermost aquifer (Tertiary gravels) at the Gunnison disposal site. The monitor well locations provide a representative distribution of sampling points to characterize ground water quality and ground water flow conditions in the vicinity of the sites. The list of analytes has been modified with time to reflect constituents that are related to uranium processing activities and the parameters needed for geochemical evaluation. Water sampling will be conducted at least semiannually during and one year following the period of construction activities, to comply with the ground water protection strategy discussed in the remedial action plan (DOE, 1992a)

  16. Nonlinear Spatial Inversion Without Monte Carlo Sampling

    Science.gov (United States)

    Curtis, A.; Nawaz, A.

    2017-12-01

    High-dimensional, nonlinear inverse or inference problems usually have non-unique solutions. The distribution of solutions are described by probability distributions, and these are usually found using Monte Carlo (MC) sampling methods. These take pseudo-random samples of models in parameter space, calculate the probability of each sample given available data and other information, and thus map out high or low probability values of model parameters. However, such methods would converge to the solution only as the number of samples tends to infinity; in practice, MC is found to be slow to converge, convergence is not guaranteed to be achieved in finite time, and detection of convergence requires the use of subjective criteria. We propose a method for Bayesian inversion of categorical variables such as geological facies or rock types in spatial problems, which requires no sampling at all. The method uses a 2-D Hidden Markov Model over a grid of cells, where observations represent localized data constraining the model in each cell. The data in our example application are seismic properties such as P- and S-wave impedances or rock density; our model parameters are the hidden states and represent the geological rock types in each cell. The observations at each location are assumed to depend on the facies at that location only - an assumption referred to as `localized likelihoods'. However, the facies at a location cannot be determined solely by the observation at that location as it also depends on prior information concerning its correlation with the spatial distribution of facies elsewhere. Such prior information is included in the inversion in the form of a training image which represents a conceptual depiction of the distribution of local geologies that might be expected, but other forms of prior information can be used in the method as desired. The method provides direct (pseudo-analytic) estimates of posterior marginal probability distributions over each variable

  17. Magnetic Characterization of Sand and Boulder Samples from Citarum River and Their Origin

    Directory of Open Access Journals (Sweden)

    Sudarningsih

    2017-09-01

    Full Text Available The Citarum River is a nationally strategic river located near Bandung, the capital city of West Java Province. The feasibility of using magnetic methods for monitoring pollution level is currently being tested in the river. Due to its location in a volcanic area, the sediments from the river are expected to be highly magnetic. In this study, sand and boulder samples from Balekambang, a relatively pristine upstream area of the river, were subjected to magnetic and geochemical characterizations to establish the baseline for unpolluted sediments. Such baseline is important for future magnetic monitoring of sediments in the river. The mass-specific magnetic susceptibility of boulder samples was found to be varied from 819.2 to 2340.5 × 10-8m3 kg-1 while that of sand samples varied from 2293.9 to 3845.3 × 10-8m3 kg-1. These high magnetic susceptibility values infer that river sediments are highly magnetic even before being contaminated by industrial and household wastes. The predominant magnetic mineral in sand samples was multi-domain magnetite while that in boulder samples was single to pseudo-single domain magnetite. These differences were supported by the results from petrographic and XRF analyses, implying that the sand and boulder samples originated from different geological formations.

  18. Sampling strategies for estimating brook trout effective population size

    Science.gov (United States)

    Andrew R. Whiteley; Jason A. Coombs; Mark Hudy; Zachary Robinson; Keith H. Nislow; Benjamin H. Letcher

    2012-01-01

    The influence of sampling strategy on estimates of effective population size (Ne) from single-sample genetic methods has not been rigorously examined, though these methods are increasingly used. For headwater salmonids, spatially close kin association among age-0 individuals suggests that sampling strategy (number of individuals and location from...

  19. Implicit Leadership Theory: Are Results Generalizable from Student to Professional Samples?

    Science.gov (United States)

    Singer, Ming

    1990-01-01

    Explores whether student subjects' implicit leadership theories are generalizable to professional subjects. Samples consisted of 220 undergraduates and 152 government employees in New Zealand. Finds the mean importance ratings were similar for the 2 samples, except students placed greater importance on factors beyond individual control. (DB)

  20. Headspace vapor characterization of Hanford waste tank 241-B-107: Results from samples collected on 7/23/96

    International Nuclear Information System (INIS)

    Evans, J.C.; Pool, K.H.; Thomas, B.L.; Olsen, K.B.; Fruchter, J.S.; Silvers, K.L.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-B-107 (Tank B-107) at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwestern National Laboratory (PNNL). A summary of the inorganic analytes, permanent gases, and total non-methane organic compounds is listed in a table. The three highest concentration analytes detected in SUMMA trademark canister and triple sorbent trap samples are also listed in the same table. Detailed descriptions of the analytical results appear in the appendices

  1. Headspace vapor characterization of Hanford waste tank 241-S-106: Results from samples collected on 06/13/96

    International Nuclear Information System (INIS)

    Evans, J.C.; Pool, K.H.; Thomas, B.L.; Olsen, K.B.; Fruchter, J.S.; Silvers, K.L.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-S-106 (Tank S-106) at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest National Laboratory (PNNL). A summary of the inorganic analytes, permanent gases, and total non-methane organic compounds is listed in a table. The three highest concentration analytes detected in SUMMA trademark canister and triple sorbent trap samples are also listed in the same table. Detailed descriptions of the analytical results appear in the appendices

  2. Location choice in the context of multi-day activity-travel patterns : model development and empirical results

    NARCIS (Netherlands)

    Arentze, T.A.; Ettema, D.F.; Timmermans, H.J.P.

    2013-01-01

    Multi-day activity-based models of travel demand are receiving increasing interest recently as successors of existing single-day activity-based models. In this article, we argue that predicting activity location choice-sets can no longer be ignored when multi-day time frames are adopted in these

  3. Location Privacy with Randomness Consistency

    Directory of Open Access Journals (Sweden)

    Wu Hao

    2016-10-01

    Full Text Available Location-Based Social Network (LBSN applications that support geo-location-based posting and queries to provide location-relevant information to mobile users are increasingly popular, but pose a location-privacy risk to posts. We investigated existing LBSNs and location privacy mechanisms, and found a powerful potential attack that can accurately locate users with relatively few queries, even when location data is well secured and location noise is applied. Our technique defeats previously proposed solutions including fake-location detection and query rate limits.

  4. Non-destructive radiometry inspection technique for locating reinforcements and void/porosity in bridge bearings

    International Nuclear Information System (INIS)

    Yahaya bin Jafar; Jaafar bin Abdullah; Mohamad Azmi bin Ismail.

    1989-01-01

    Defects detection in bridge bearings is very important in controlling quality and safety. Typical manufacturing defects include misalligned or bent steel plates and the presence of voids/porosity within the rubber. A non-destructive radiometry inspection technique was used to locate steel plates position and the presence of voids/porosity in bridge bearing samples provided by the Rubber Research Institute of Malaysia (RRIM). Preliminary studies show that the mentioned defects can readily be determined by this technique. Some of the results are also presented. (author)

  5. Vapor space characterization of Waste Tank 241-TY-104: Results from samples collected on 4/27/95

    International Nuclear Information System (INIS)

    Klinger, G.S.; Olsen, K.B.; Clauss, T.W.

    1995-10-01

    This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-TY-104 (referred to as Tank TY-104). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH 3 ), nitrogen dioxide (NO 2 ), nitric oxide (NO), and water (H 2 O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO x ) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, 8 were observed above the 5-ppbv reporting cutoff. Five tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 94% of the total organic components in Tank TY-104. Nitrous oxide (N 2 O) was the only permanent gas detected in the tank-headspace samples. Tank TY-104 is on the Ferrocyanide Watch List

  6. Vapor space characterization of Waste Tank 241-U-105: Results from samples collected on 2/24/95

    International Nuclear Information System (INIS)

    Pool, K.H.; Clauss, T.W.; Ligotke, M.W.

    1995-10-01

    This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-U-105 (referred to as Tank U-105). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH 3 ), nitrogen dioxide (NO 2 ), nitric oxide (NO), and water (H 2 O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO x ) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, six were observed above the 5-ppbv reporting cutoff. Three tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. All nine of the organic analytes identified are listed in Table 1 and account for 100% of the total organic components in Tank U-105. Nitrous oxide (N 2 O) was the only permanent gas detected in the tank-headspace sample. Tank U-105 is on the Hydrogen Watch List

  7. Vapor space characterization of waste Tank 241-SX-103: Results from samples collected on 3/23/95

    International Nuclear Information System (INIS)

    Ligotke, M.W.; Clauss, T.W.; Pool, K.H.; McVeety, B.D.; Klinger, G.S.; Olsen, K.B.; Bredt, O.P.; Fruchter, J.S.; Goheen, S.C.

    1995-11-01

    This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage tank 241-SX-103 (referred to as Tank SX-103). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH 3 ), nitrogen dioxide (NO 2 ), nitric oxide (NO), and water vapor (H 2 O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO x ) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, two were observed above the 5-ppbv reporting cutoff. Two tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The four organic analytes identified are listed in Table 1 and account for approximately 100% of the total organic components in Tank SX-103. Carbon dioxide (CO 2 ) was the only permanent gas detected in the tank-headspace samples. Tank SX-103 is on the Hydrogen Watch List

  8. WHERE2 Location Aided Communications

    DEFF Research Database (Denmark)

    Dammann, Armin; Agapiou, George; Brunel, Loïc

    2013-01-01

    This paper presents an overview of preliminary results of investigations within the WHERE2 Project on identifying promising avenues for location aided enhancements to wireless communication systems. The wide ranging contributions are organized according to the following targeted systems: cellular...

  9. Radiological air monitoring and sample analysis research and development progress report

    International Nuclear Information System (INIS)

    1992-01-01

    Sponsored by a Department Of Energy (DOE) research and development grant, the State of Idaho INEL Oversight Program (OP) personnel designed an independent air monitoring system that provides detection of the presence of priority airborne contaminants potentially migrating beyond INEL boundaries. Initial locations for off-site ambient air monitoring stations were chosen in consultation with: DOE and NOAA reports; Mesodif modeling; review of the relevant literature; and communication with private contractors and experts in pertinent fields. Idaho State University (ISU) has initiated an Environmental Monitoring Program (EMP). The EMP provides an independent monitoring function as well as a training ground for students. Students learn research techniques dedicated to environmental studies and learn analytical skills and rules of compliance related to monitoring. ISU-EMP assisted OP in specific aspects of identifying optimum permanent monitoring station locations, and in selecting appropriate sample collection equipment for each station. The authorization to establish, prepare and install sampling devices on selected sites was obtained by OP personnel in conjunction with ISU-EMP personnel. All samples described in this program are collected by OP or ISU-EMP personnel and returned to the ISU for analysis. This report represents the summary of results of those samples collected and analyzed for radioactivity during the year of 1992

  10. How different location modes influence responses in a Simon-like task.

    Science.gov (United States)

    Luo, Chunming; Proctor, Robert W

    2017-11-01

    Spatial information can be conveyed not only by stimulus position but by the meaning of a location word or direction of an arrow. We examined whether all the location-, arrow- and word-based Simon effects or some of them can be observed when a location word or an arrow is presented eccentrically and a left-right keypress is made to indicate its ink color. Results showed that only the location-based Simon effect was observed for location words, whereas an additional smaller arrow-based Simon effect, compared to the location-based Simon effect was observed, for arrows. These results showed spatial location, arrow direction, and location word stimulus dimensions affect response position codes in a spatial-to-verbal priority order, consistent with the possibility that they can activate mode-specific spatial representations.

  11. Cross-modal and intra-modal binding between identity and location in spatial working memory: The identity of objects does not help recalling their locations.

    Science.gov (United States)

    Del Gatto, Claudia; Brunetti, Riccardo; Delogu, Franco

    2016-01-01

    In this study we tested incidental feature-to-location binding in a spatial task, both in unimodal and cross-modal conditions. In Experiment 1 we administered a computerised version of the Corsi Block-Tapping Task (CBTT) in three different conditions: the first one analogous to the original CBTT test; the second one in which locations were associated with unfamiliar images; the third one in which locations were associated with non-verbal sounds. Results showed no effect on performance by the addition of identity information. In Experiment 2, locations on the screen were associated with pitched sounds in two different conditions: one in which different pitches were randomly associated with locations and the other in which pitches were assigned to match the vertical position of the CBTT squares congruently with their frequencies. In Experiment 2 we found marginal evidence of a pitch facilitation effect in the spatial memory task. We ran a third experiment to test the same conditions of Experiment 2 with a within-subject design. Results of Experiment 3 did not confirm the pitch-location facilitation effect. We concluded that the identity of objects does not affect recalling their locations. We discuss our results within the framework of the debate about the mechanisms of "what" and "where" feature binding in working memory.

  12. Considering the Epistemic Uncertainties of the Variogram Model in Locating Additional Exploratory Drillholes

    Directory of Open Access Journals (Sweden)

    Saeed Soltani

    2015-06-01

    Full Text Available To enhance the certainty of the grade block model, it is necessary to increase the number of exploratory drillholes and collect more data from the deposit. The inputs of the process of locating these additional drillholes include the variogram model parameters, locations of the samples taken from the initial drillholes, and the geological block model. The uncertainties of these inputs will lead to uncertainties in the optimal locations of additional drillholes. Meanwhile, the locations of the initial data are crisp, but the variogram model parameters and the geological model have uncertainties due to the limitation of the number of initial data. In this paper, effort has been made to consider the effects of variogram uncertainties on the optimal location of additional drillholes using the fuzzy kriging and solve the locating problem with the genetic algorithm (GA optimization method.A bauxite deposit case study has shown the efficiency of the proposed model.

  13. Smartphones as locative media

    CERN Document Server

    Frith, Jordan

    2015-01-01

    Smartphone adoption has surpassed 50% of the population in more than 15 countries, and there are now more than one million mobile applications people can download to their phones. Many of these applications take advantage of smartphones as locative media, which is what allows smartphones to be located in physical space. Applications that take advantage of people's location are called location-based services, and they are the focus of this book. Smartphones as locative media raise important questions about how we understand the complicated relationship between the Internet and physical space

  14. Identification of sources of aerosol particles in three locations in eastern Botswana

    Science.gov (United States)

    Chimidza, S.; Moloi, K.

    2000-07-01

    Airborne particles have been collected using a dichotomous virtual impactor at three different locations in the eastern part of Botswana: Serowe, Selibe-Phikwe, and Francistown. The particles were separated into two fractions (fine and coarse). Sampling at the three locations was done consecutively during the months of July and August, which are usually dry and stable. The sampling time for each sample was 12 hours during the day. For elemental composition, energy-dispersive x-ray fluorescence technique was used. Correlations and principal component analysis with varimax rotation were used to identify major sources of aerosol particles. In all the three places, soil was found to be the main source of aerosol particles. A copper-nickel mine and smelter at Selibe-Phikwe was found to be not only a source of copper and nickel particles in Selibe-Phikwe but also a source of these particles in far places like Serowe. In Selibe-Phikwe and Francistown, car exhaust was found to be the major source of fine particles of lead and bromine.

  15. Location Intelligence Solutions

    International Nuclear Information System (INIS)

    Schmidt, D.

    2015-01-01

    Location Intelligence (LI) means using the spatial dimension of information as a key to support business processes. This spatial dimension has to be defined by geographic coordinates. Storing these spatial objects in a database allows for attaching a 'meaning' to them, like 'current position', 'border', 'building' or 'room'. Now the coordinates represent real-world objects, which can be relevant for the measurement, documentation, control or optimization of (parameters of) business processes aiming at different business objectives. But LI can only be applied, if the locations can be determined with an accuracy (in space and time) appropriate for the business process in consideration. Therefore the first step in any development of a LI solution is the analysis of the business process itself regarding its requirements for spatial and time resolution and accuracy. The next step is the detailed analysis of the surrounding conditions of the process: Does the process happen indoor and/or outdoor? Are there moving objects? If yes, how fast are they? How does the relevant environment look like? Is technical infrastructure available? Is the process restricted by regulations? As a result, a proper Location Detection Technology (LDT) has to be chosen in order to get reliable and accurate positions of the relevant objects. At the highly challenging conditions of the business processes IAEA inspectors are working with, the chosen LDTs have to deliver reliable positioning on ''room-level'' accuracy, even if there is no location enabling infrastructure in place, the objects (people) mostly are indoors and have to work under strong regulations. The presentation will give insights into innovative LI solutions based on technologies of different LDT providers. Pros and cons of combinations of different LDT (like multi- GNSS, IMU, camera, and human interaction based positioning) will be discussed from the

  16. Sample Results From The Interim Salt Disposition Program Macrobatch 7 Tank 21H Qualification Samples

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. B.; Washington, A. L. II

    2013-08-08

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 7 for the Interim Salt Disposition Program (ISDP). An ARP and several ESS tests were also performed. This document reports characterization data on the samples of Tank 21H as well as simulated performance of ARP/MCU. No issues with the projected Salt Batch 7 strategy are identified, other than the presence of visible quantities of dark colored solids. A demonstration of the monosodium titanate (0.2 g/L) removal of strontium and actinides provided acceptable 4 hour average decontamination factors for Pu and Sr of 3.22 and 18.4, respectively. The Four ESS tests also showed acceptable behavior with distribution ratios (D(Cs)) values of 15.96, 57.1, 58.6, and 65.6 for the MCU, cold blend, hot blend, and Next Generation Solvent (NGS), respectively. The predicted value for the MCU solvent was 13.2. Currently, there are no models that would allow a prediction of extraction behavior for the other three solvents. SRNL recommends that a model for predicting extraction behavior for cesium removal for the blended solvent and NGS be developed. While no outstanding issues were noted, the presence of solids in the samples should be investigated in future work. It is possible that the solids may represent a potential reservoir of material (such as potassium) that could have an impact on MCU performance if they were to dissolve back into the feed solution. This salt batch is intended to be the first batch to be processed through MCU entirely using the new NGS-MCU solvent.

  17. Note: A simple image processing based fiducial auto-alignment method for sample registration.

    Science.gov (United States)

    Robertson, Wesley D; Porto, Lucas R; Ip, Candice J X; Nantel, Megan K T; Tellkamp, Friedjof; Lu, Yinfei; Miller, R J Dwayne

    2015-08-01

    A simple method for the location and auto-alignment of sample fiducials for sample registration using widely available MATLAB/LabVIEW software is demonstrated. The method is robust, easily implemented, and applicable to a wide variety of experiment types for improved reproducibility and increased setup speed. The software uses image processing to locate and measure the diameter and center point of circular fiducials for distance self-calibration and iterative alignment and can be used with most imaging systems. The method is demonstrated to be fast and reliable in locating and aligning sample fiducials, provided here by a nanofabricated array, with accuracy within the optical resolution of the imaging system. The software was further demonstrated to register, load, and sample the dynamically wetted array.

  18. Law Enforcement Locations

    Data.gov (United States)

    Kansas Data Access and Support Center — Law Enforcement Locations in Kansas Any location where sworn officers of a law enforcement agency are regularly based or stationed. Law enforcement agencies "are...

  19. Assessing genetic polymorphisms using DNA extracted from cells present in saliva samples

    Directory of Open Access Journals (Sweden)

    Nemoda Zsofia

    2011-12-01

    Full Text Available Abstract Background Technical advances following the Human Genome Project revealed that high-quality and -quantity DNA may be obtained from whole saliva samples. However, usability of previously collected samples and the effects of environmental conditions on the samples during collection have not been assessed in detail. In five studies we document the effects of sample volume, handling and storage conditions, type of collection device, and oral sampling location, on quantity, quality, and genetic assessment of DNA extracted from cells present in saliva. Methods Saliva samples were collected from ten adults in each study. Saliva volumes from .10-1.0 ml, different saliva collection devices, sampling locations in the mouth, room temperature storage, and multiple freeze-thaw cycles were tested. One representative single nucleotide polymorphism (SNP in the catechol-0-methyltransferase gene (COMT rs4680 and one representative variable number of tandem repeats (VNTR in the serotonin transporter gene (5-HTTLPR: serotonin transporter linked polymorphic region were selected for genetic analyses. Results The smallest tested whole saliva volume of .10 ml yielded, on average, 1.43 ± .77 μg DNA and gave accurate genotype calls in both genetic analyses. The usage of collection devices reduced the amount of DNA extracted from the saliva filtrates compared to the whole saliva sample, as 54-92% of the DNA was retained on the device. An "adhered cell" extraction enabled recovery of this DNA and provided good quality and quantity DNA. The DNA from both the saliva filtrates and the adhered cell recovery provided accurate genotype calls. The effects of storage at room temperature (up to 5 days, repeated freeze-thaw cycles (up to 6 cycles, and oral sampling location on DNA extraction and on genetic analysis from saliva were negligible. Conclusions Whole saliva samples with volumes of at least .10 ml were sufficient to extract good quality and quantity DNA. Using

  20. Space Geodetic Technique Co-location in Space: Simulation Results for the GRASP Mission

    Science.gov (United States)

    Kuzmicz-Cieslak, M.; Pavlis, E. C.

    2011-12-01

    The Global Geodetic Observing System-GGOS, places very stringent requirements in the accuracy and stability of future realizations of the International Terrestrial Reference Frame (ITRF): an origin definition at 1 mm or better at epoch and a temporal stability on the order of 0.1 mm/y, with similar numbers for the scale (0.1 ppb) and orientation components. These goals were derived from the requirements of Earth science problems that are currently the international community's highest priority. None of the geodetic positioning techniques can achieve this goal alone. This is due in part to the non-observability of certain attributes from a single technique. Another limitation is imposed from the extent and uniformity of the tracking network and the schedule of observational availability and number of suitable targets. The final limitation derives from the difficulty to "tie" the reference points of each technique at the same site, to an accuracy that will support the GGOS goals. The future GGOS network will address decisively the ground segment and to certain extent the space segment requirements. The JPL-proposed multi-technique mission GRASP (Geodetic Reference Antenna in Space) attempts to resolve the accurate tie between techniques, using their co-location in space, onboard a well-designed spacecraft equipped with GNSS receivers, a SLR retroreflector array, a VLBI beacon and a DORIS system. Using the anticipated system performance for all four techniques at the time the GGOS network is completed (ca 2020), we generated a number of simulated data sets for the development of a TRF. Our simulation studies examine the degree to which GRASP can improve the inter-technique "tie" issue compared to the classical approach, and the likely modus operandi for such a mission. The success of the examined scenarios is judged by the quality of the origin and scale definition of the resulting TRF.