WorldWideScience

Sample records for samples urine samples

  1. Urine sample collection protocols for bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject`s body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  2. Urine sample collection protocols for bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject's body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  3. Monitoring human papillomavirus prevalence in urine samples: a review

    Directory of Open Access Journals (Sweden)

    Enerly E

    2013-03-01

    Full Text Available Espen Enerly, Cecilia Olofsson, Mari NygårdDepartment of Research, Cancer Registry of Norway, Oslo, NorwayAbstract: Human papillomavirus (HPV is the main cause of cervical cancer, and many countries now offer vaccination against HPV to girls by way of government-funded national immunization programs. Monitoring HPV prevalence in adolescents could offer a near-term biological measure of vaccine impact, and urine sampling may be an attractive large-scale method that could be used for this purpose. Our objective was to provide an overview of the literature on HPV DNA detection in urine samples, with an emphasis on adolescents. We searched the PubMed database using the terms “HPV” and “urine” and identified 21 female and 14 male study populations in which HPV prevalence in urine samples was reported, four of which included only asymptomatic female adolescents. We provide herein an overview of the recruitment setting, age, urine sampling procedure, lesion type, HPV assay, and HPV prevalence in urine samples and other urogenital samples for the studies included in this review. In female study populations, concordance for any HPV type and type-specific concordance in paired urine and cervical samples are provided in addition to sensitivity and specificity. We concluded that few studies on HPV prevalence in urine samples have been performed in asymptomatic female adolescent populations but that urine samples may be a useful alternative to cervical samples to monitor changes in HPV prevalence in females in the post-HPV vaccination era. However, care should be taken when extrapolating HPV findings from urine samples to the cervix. In males, urine samples do not seem to be optimal for monitoring HPV prevalence due to a low human genomic DNA content and HPV DNA detection rate compared to other urogenital sites. In each situation the costs and benefits of HPV DNA detection in urine compared to alternative monitoring options should be carefully

  4. Urine sample preparation for proteomic analysis.

    Science.gov (United States)

    Olszowy, Pawel; Buszewski, Boguslaw

    2014-10-01

    Sample preparation for both environmental and more importantly biological matrices is a bottleneck of all kinds of analytical processes. In the case of proteomic analysis this element is even more important due to the amount of cross-reactions that should be taken into consideration. The incorporation of new post-translational modifications, protein hydrolysis, or even its degradation is possible as side effects of proteins sample processing. If protocols are evaluated appropriately, then identification of such proteins does not bring difficulties. However, if structural changes are provided without sufficient attention then protein sequence coverage will be reduced or even identification of such proteins could be impossible. This review summarizes obstacles and achievements in protein sample preparation of urine for proteome analysis using different tools for mass spectrometry analysis. The main aim is to present comprehensively the idea of urine application as a valuable matrix. This article is dedicated to sample preparation and application of urine mainly in novel cancer biomarkers discovery. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Quality Control Samples for the Radiological Determination of Tritium in Urine Samples

    International Nuclear Information System (INIS)

    Ost'pezuk, P.; Froning, M.; Laumen, S.; Richert, I.; Hill, P.

    2004-01-01

    The radioactive decay product of tritium is a low energy beta that cannot penetrate the outer dead layer of human skin. Therefore , the main hazard associated with tritium is internal exposure. In addition, due to the relatively long half life and short biological half life, tritium must be ingested in large amounts to pose a significant health risk. On the other hand, the internal exposure should be kept as low as practical. For incorporation monitoring of professional radiation workers the quality control is of utmost importance. In the Research Centre Juelich GmbH (FZJ) a considerable fraction of monitoring by excretion analysis relates to the isotope Tritium. Usually an aliquot of an urine sample is mixed with a liquid scintillator and measured in a liquid scintillation counter. Quality control samples in the form of three kind of internal reference samples (blank, reference samples with low activity and reference sample with elevated activity) were prepared from a mixed, Tritium (free) urine samples. 1 ml of these samples were pipetted into a liquid scintillation vial. In the part of theses vials a known amounts of Tritium were added. All these samples were stored at 20 degrees. Based on long term use of all these reference samples it was possible to construct appropriate control charts with the upper and lower alarm limits. Daily use of these reference samples decrease significantly the risk for false results in original urine with no significant increase of the determination time. (Author) 2 refs

  6. Urine sampling techniques in symptomatic primary-care patients

    DEFF Research Database (Denmark)

    Holm, Anne; Aabenhus, Rune

    2016-01-01

    in infection rate between mid-stream-clean-catch, mid-stream-urine and random samples. Conclusions: At present, no evidence suggests that sampling technique affects the accuracy of the microbiological diagnosis in non-pregnant women with symptoms of urinary tract infection in primary care. However......Background: Choice of urine sampling technique in urinary tract infection may impact diagnostic accuracy and thus lead to possible over- or undertreatment. Currently no evidencebased consensus exists regarding correct sampling technique of urine from women with symptoms of urinary tract infection...... a randomized or paired design to compare the result of urine culture obtained with two or more collection techniques in adult, female, non-pregnant patients with symptoms of urinary tract infection. We evaluated quality of the studies and compared accuracy based on dichotomized outcomes. Results: We included...

  7. Estimating mean change in population salt intake using spot urine samples.

    Science.gov (United States)

    Petersen, Kristina S; Wu, Jason H Y; Webster, Jacqui; Grimes, Carley; Woodward, Mark; Nowson, Caryl A; Neal, Bruce

    2017-10-01

    Spot urine samples are easier to collect than 24-h urine samples and have been used with estimating equations to derive the mean daily salt intake of a population. Whether equations using data from spot urine samples can also be used to estimate change in mean daily population salt intake over time is unknown. We compared estimates of change in mean daily population salt intake based upon 24-h urine collections with estimates derived using equations based on spot urine samples. Paired and unpaired 24-h urine samples and spot urine samples were collected from individuals in two Australian populations, in 2011 and 2014. Estimates of change in daily mean population salt intake between 2011 and 2014 were obtained directly from the 24-h urine samples and by applying established estimating equations (Kawasaki, Tanaka, Mage, Toft, INTERSALT) to the data from spot urine samples. Differences between 2011 and 2014 were calculated using mixed models. A total of 1000 participants provided a 24-h urine sample and a spot urine sample in 2011, and 1012 did so in 2014 (paired samples n = 870; unpaired samples n = 1142). The participants were community-dwelling individuals living in the State of Victoria or the town of Lithgow in the State of New South Wales, Australia, with a mean age of 55 years in 2011. The mean (95% confidence interval) difference in population salt intake between 2011 and 2014 determined from the 24-h urine samples was -0.48g/day (-0.74 to -0.21; P spot urine samples was -0.24 g/day (-0.42 to -0.06; P = 0.01) using the Tanaka equation, -0.42 g/day (-0.70 to -0.13; p = 0.004) using the Kawasaki equation, -0.51 g/day (-1.00 to -0.01; P = 0.046) using the Mage equation, -0.26 g/day (-0.42 to -0.10; P = 0.001) using the Toft equation, -0.20 g/day (-0.32 to -0.09; P = 0.001) using the INTERSALT equation and -0.27 g/day (-0.39 to -0.15; P  0.058). Separate analysis of the unpaired and paired data showed that detection of

  8. Tritium analysis of urine samples from the general Korean public.

    Science.gov (United States)

    Yoon, Seokwon; Ha, Wi-Ho; Lee, Seung-Sook

    2013-11-01

    The tritium concentrations of urine samples and the effective dose of the general Korean public were evaluated. To achieve accurate HTO analysis of urine samples, we established the optimal conditions for measuring the HTO content of urine samples. Urine samples from 50 Koreans who do not work at a nuclear facility were analyzed on the basis of the results. The average urine analysis result was 2.8 ±1 .4 Bq/L, and the range was 1.8-5.6 Bq/L. The measured values were lower than those reported for other countries. These results show that environmental factors and lifestyle differences are the main factors affecting the tritium level of the general public. © 2013 Elsevier Ltd. All rights reserved.

  9. Immunoreactive LH in long-term frozen human urine samples.

    Science.gov (United States)

    Singh, Gurmeet Kaur Surindar; Jimenez, Mark; Newman, Ron; Handelsman, David J

    2014-04-01

    Urine provides a convenient non-invasive alternative to blood sampling for measurement of certain hormones. Urinary luteinizing hormone (LH) measurements have been used for endocrinology research and anti-doping testing. However, the commercially available LH immunoassays are developed and validated for human blood samples but not urine so that LH assays intended for use with urine samples need thorough validation. Therefore, the present study evaluated the measurement of urinary LH immunoreactivity using previously validated immunofluorometric (IF) and immunochemiluminometric (ICL) LH assays after prolonged frozen storage. LH was measured in serial urine samples following administration of a single injection of one of two doses of recombinant human chorionic hormone (rhCG) with assays run at the end of study (2008) and again after four years of frozen (-20 °C) storage where samples were stored without adding preservatives. The ICL assay showed quantitatively reproducible LH measurements after prolonged -20 °C storage. However, the IF immunoassay gave consistently lower LH levels relative to ICL (2008) with a further proportionate reduction after four years of sample storage (2012). Yet, both the assays displayed similar patterns of the time-course of urine LH measurement both before and after four years of frozen storage. In conclusion, we found that both immunoassays are suitable for urinary LH measurements with ICL assay being more robust for quantitative urinary LH measurement such as for anti-doping purposes, whereas the IF could be applicable for research studies where urine LH levels are compared within-study but not in absolute terms. Copyright © 2013 John Wiley & Sons, Ltd.

  10. Estimation of creatinine in Urine sample by Jaffe's method

    International Nuclear Information System (INIS)

    Wankhede, Sonal; Arunkumar, Suja; Sawant, Pramilla D.; Rao, B.B.

    2012-01-01

    In-vitro bioassay monitoring is based on the determination of activity concentrations in biological samples excreted from the body and is most suitable for alpha and beta emitters. A truly representative bioassay sample is the one having all the voids collected during a 24-h period however, this being technically difficult, overnight urine samples collected by the workers are analyzed. These overnight urine samples are collected for 10-16 h, however in the absence of any specific information, 12 h duration is assumed and the observed results are then corrected accordingly obtain the daily excretion rate. To reduce the uncertainty due to unknown duration of sample collection, IAEA has recommended two methods viz., measurement of specific gravity and creatinine excretion rate in urine sample. Creatinine is a final metabolic product creatinine phosphate in the body and is excreted at a steady rate for people with normally functioning kidneys. It is, therefore, often used as a normalization factor for estimation of duration of sample collection. The present study reports the chemical procedure standardized and its application for the estimation of creatinine in urine samples collected from occupational workers. Chemical procedure for estimation of creatinine in bioassay samples was standardized and applied successfully for its estimation in bioassay samples collected from the workers. The creatinine excretion rate observed for these workers is lower than observed in literature. Further, work is in progress to generate a data bank of creatinine excretion rate for most of the workers and also to study the variability in creatinine coefficient for the same individual based on the analysis of samples collected for different duration

  11. HPLC determination of betamethasone and prednisolone in urine samples using monolithic column

    International Nuclear Information System (INIS)

    Abro, K.; Memon, N.; Bhanger, M.I.

    2011-01-01

    A fast and reliable HPLC method is reported for the separation and quantification of betamethasone and prednisolone in urine samples using Chromolith at the rate of Performance RP-l8e (100 mm x 4.6 mm) column. The separation and detection was achieved using an isocratic mobile phase composed of methanol:water (44:56 v/v) at 2.0 mL/min and wavelength of 254 nm. After successful optimisation of method parameters, it was applied to the urine samples. Solid phase extraction technique was used to clean the sample before analysis. The developed method was validated for the system suitability, precision and accuracy. The limits of defection for the prednisolone and betamethasone are 0.11 ng and 0.075 ng/10 macro L injection, respectively allowing their determination in human urine samples. Recovery for spiked urine samples was in the range of 97-103 %. The method offers a valuable alternative to the methodologies currently employed for separation and quantification of prednisolone and betamethasone in urine samples. A fast and reliable HPLC method is reported for the separation and quantification of betamethasone and prednisolone in urine samples using Chromolith at the rate of Performance RP-l8e (100 mm x 4.6 mm) column. The separation and detection was achieved using an isocratic mobile phase composed of methanol:water (44:56 v/v) at 2.0 mL/min and wavelength of 254 nm. After successful optimisation of method parameters, it was applied to the urine samples. Solid phase extraction technique was used to clean the sample before analysis. The developed method was validated for the system suitability, precision and accuracy. The limits of defection for the prednisolone and betamethasone are 0.11 ng and 0.075 ng/10 macro L injection, respectively allowing their determination in human urine samples. Recovery for spiked urine samples was in the range of 97-103 %. The method offers a valuable alternative to the methodologies currently employed for separation and quantification

  12. The importance of cooling of urine samples for doping analysis

    NARCIS (Netherlands)

    Kuenen, J. Gijs; Konings, Wil N.

    Storing and transporting of urine samples for doping analysis, as performed by the anti-doping organizations associated with the World Anti-Doping Agency, does not include a specific protocol for cooled transport from the place of urine sampling to the doping laboratory, although low cost cooling

  13. Ultrasonic-based membrane aided sample preparation of urine proteomes.

    Science.gov (United States)

    Jesus, Jemmyson Romário; Santos, Hugo M; López-Fernández, H; Lodeiro, Carlos; Arruda, Marco Aurélio Zezzi; Capelo, J L

    2018-02-01

    A new ultrafast ultrasonic-based method for shotgun proteomics as well as label-free protein quantification in urine samples is developed. The method first separates the urine proteins using nitrocellulose-based membranes and then proteins are in-membrane digested using trypsin. The enzymatic digestion process is accelerated from overnight to four minutes using a sonoreactor ultrasonic device. Overall, the sample treatment pipeline comprising protein separation, digestion and identification is done in just 3h. The process is assessed using urine of healthy volunteers. The method shows that male can be differentiated from female using the protein content of urine in a fast, easy and straightforward way. 232 and 226 proteins are identified in urine of male and female, respectively. From this, 162 are common to both genders, whilst 70 are unique to male and 64 to female. From the 162 common proteins, 13 are present at levels statistically different (p minimalism concept as outlined by Halls, as each stage of this analysis is evaluated to minimize the time, cost, sample requirement, reagent consumption, energy requirements and production of waste products. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Importance of sample preparation for molecular diagnosis of lyme borreliosis from urine.

    Science.gov (United States)

    Bergmann, A R; Schmidt, B L; Derler, A-M; Aberer, E

    2002-12-01

    Urine PCR has been used for the diagnosis of Borrelia burgdorferi infection in recent years but has been abandoned because of its low sensitivity and the irreproducibility of the results. Our study aimed to analyze technical details related to sample preparation and detection methods. Crucial for a successful urine PCR were (i) avoidance of the first morning urine sample; (ii) centrifugation at 36,000 x g; and (iii) the extraction method, with only DNAzol of the seven different extraction methods used yielding positive results with patient urine specimens. Furthermore, storage of frozen urine samples at -80 degrees C reduced the sensitivity of a positive urine PCR result obtained with samples from 72 untreated erythema migrans (EM) patients from 85% in the first 3 months to samples was proven by hybridization with a GEN-ETI-K-DEIA kit and for a 10 further positive amplicons by sequencing. By using all of these steps to optimize the urine PCR technique, B. burgdorferi infection could be diagnosed by using urine samples from EM patients with a sensitivity (85%) substantially better than that of serological methods (50%). This improved method could be of future importance as an additional laboratory technique for the diagnosis of unclear, unrecognized borrelia infections and diseases possibly related to Lyme borreliosis.

  15. Sample preparation and storage can change arsenic speciation in human urine.

    Science.gov (United States)

    Feldmann, J; Lai, V W; Cullen, W R; Ma, M; Lu, X; Le, X C

    1999-11-01

    Stability of chemical speciation during sample handling and storage is a prerequisite to obtaining reliable results of trace element speciation analysis. There is no comprehensive information on the stability of common arsenic species, such as inorganic arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid, dimethylarsinic acid, and arsenobetaine, in human urine. We compared the effects of the following storage conditions on the stability of these arsenic species: temperature (25, 4, and -20 degrees C), storage time (1, 2, 4, and 8 months), and the use of additives (HCl, sodium azide, benzoic acid, benzyltrimethylammonium chloride, and cetylpyridinium chloride). HPLC with both inductively coupled plasma mass spectrometry and hydride generation atomic fluorescence detection techniques were used for the speciation of arsenic. We found that all five of the arsenic species were stable for up to 2 months when urine samples were stored at 4 and -20 degrees C without any additives. For longer period of storage (4 and 8 months), the stability of arsenic species was dependent on urine matrices. Whereas the arsenic speciation in some urine samples was stable for the entire 8 months at both 4 and -20 degrees C, other urine samples stored under identical conditions showed substantial changes in the concentration of As(III), As(V), monomethylarsonic acid, and dimethylarsinic acid. The use of additives did not improve the stability of arsenic speciation in urine. The addition of 0.1 mol/L HCl (final concentration) to urine samples produced relative changes in inorganic As(III) and As(V) concentrations. Low temperature (4 and -20 degrees C) conditions are suitable for the storage of urine samples for up to 2 months. Untreated samples maintain their concentration of arsenic species, and additives have no particular benefit. Strong acidification is not appropriate for speciation analysis.

  16. Effect of blood contamination on results of dipstick evaluation and urine protein-to-urine creatinine ratio for urine samples from dogs and cats.

    Science.gov (United States)

    Vientós-Plotts, Aida I; Behrend, Ellen N; Welles, Elizabeth G; Chew, Dennis J; Gaillard, Philippe R; Busler, Jessica N; Lee, Hollie P

    2018-05-01

    OBJECTIVE To evaluate effects of blood contamination on dipstick results, specific gravity (SG), and urine protein-to-urine creatinine ratio (UPCR) for urine samples from dogs and cats. SAMPLE Urine samples collected from 279 dogs and 120 cats. PROCEDURES Urine pools were made for each species (dogs [n = 60] and cats [30]). Blood was added to an aliquot of a pool, and serial dilutions were prepared with the remaining urine. Color and dipstick variables were recorded, and SG and UPCR were measured. For cats, 1 set of pools was used; for dogs, 2 sets were used. Comparisons were made between undiluted urine and spiked urine samples for individual colors. Repeated-measures ANOVA on ranks was used to compare dipstick scores and UPCR results; χ 2 tests were used to compare proteinuria categorizations (nonproteinuric, borderline, or proteinuric). RESULTS Any blood in the urine resulted in significantly increased dipstick scores for blood. In both species, scores for bilirubin and ketones, pH, and SG were affected by visible blood contamination. No significant difference for the dipstick protein reagent results was evident until a sample was visibly hematuric. The UPCR was significantly increased in dark yellow samples of both species. Proteinuria categorizations differed significantly between undiluted urine and urine of all colors, except light yellow. CONCLUSIONS AND CLINICAL RELEVANCE Any degree of blood contamination affected results of dipstick analysis. Effects depended on urine color and the variable measured. Microscopic blood contamination may affect the UPCR; thus, blood contamination may be a differential diagnosis for proteinuria in yellow urine samples.

  17. Estimating population salt intake in India using spot urine samples.

    Science.gov (United States)

    Petersen, Kristina S; Johnson, Claire; Mohan, Sailesh; Rogers, Kris; Shivashankar, Roopa; Thout, Sudhir Raj; Gupta, Priti; He, Feng J; MacGregor, Graham A; Webster, Jacqui; Santos, Joseph Alvin; Krishnan, Anand; Maulik, Pallab K; Reddy, K Srinath; Gupta, Ruby; Prabhakaran, Dorairaj; Neal, Bruce

    2017-11-01

    To compare estimates of mean population salt intake in North and South India derived from spot urine samples versus 24-h urine collections. In a cross-sectional survey, participants were sampled from slum, urban and rural communities in North and in South India. Participants provided 24-h urine collections, and random morning spot urine samples. Salt intake was estimated from the spot urine samples using a series of established estimating equations. Salt intake data from the 24-h urine collections and spot urine equations were weighted to provide estimates of salt intake for Delhi and Haryana, and Andhra Pradesh. A total of 957 individuals provided a complete 24-h urine collection and a spot urine sample. Weighted mean salt intake based on the 24-h urine collection, was 8.59 (95% confidence interval 7.73-9.45) and 9.46 g/day (8.95-9.96) in Delhi and Haryana, and Andhra Pradesh, respectively. Corresponding estimates based on the Tanaka equation [9.04 (8.63-9.45) and 9.79 g/day (9.62-9.96) for Delhi and Haryana, and Andhra Pradesh, respectively], the Mage equation [8.80 (7.67-9.94) and 10.19 g/day (95% CI 9.59-10.79)], the INTERSALT equation [7.99 (7.61-8.37) and 8.64 g/day (8.04-9.23)] and the INTERSALT equation with potassium [8.13 (7.74-8.52) and 8.81 g/day (8.16-9.46)] were all within 1 g/day of the estimate based upon 24-h collections. For the Toft equation, estimates were 1-2 g/day higher [9.94 (9.24-10.64) and 10.69 g/day (9.44-11.93)] and for the Kawasaki equation they were 3-4 g/day higher [12.14 (11.30-12.97) and 13.64 g/day (13.15-14.12)]. In urban and rural areas in North and South India, most spot urine-based equations provided reasonable estimates of mean population salt intake. Equations that did not provide good estimates may have failed because specimen collection was not aligned with the original method.

  18. Prednisolone and prednisone neo-formation in bovine urine after sampling.

    Science.gov (United States)

    Arioli, F; Casati, A; Fidani, M; Silvestri, M; Pompa, G

    2012-06-01

    The rise in the frequency of detecting prednisolone in bovine urine from northern Italy has come into focus of attention in recent years. The possibility that neo-formation of prednisolone or that prednisone may occur in urine after collection of samples was therefore investigated. Cow urine collected for official routine controls in Lombardy containing more than 80 ng/ml cortisol, and prednisolone and prednisone below the decision limit (CCα) of the method (0.4 and 0.5 ng/ml, respectively) was used. The C1-2 dehydrogenation of naturally present cortisol and cortisone was checked by incubating urine, both contaminated and uncontaminated with faeces, at 37°C and by collecting samples at 0, 1, 2, 4, 6 and 24 h. The influence of Helix pomatia juice was also investigated in order to determine whether deconjugation could influence the reliability of the results. All samples were analysed by HPLC-MS3 for the presence of cortisol, cortisone, prednisolone and prednisone in negative electrospray ionisation mode, utilising the consecutive reaction monitoring of product ions derived from the formate molecular adduct ([M+HCOO]-). The observed neo-formation of prednisolone shows that inappropriate temperatures in sample storage and processing can result in an incorrect accusation of non-compliance. The faecal contamination of urine, performed with the aim to mimic a collection conducted without the necessary care, moreover, evoked a high increase in prednisolone concentration in two out of seven animals. Moreover, H. pomatia juice had no significant effect on the prednisolone concentration, indicating that this corticosteroid is present in its free form in cow urine.

  19. Human Papillomavirus Detection from Human Immunodeficiency Virus-Infected Colombian Women's Paired Urine and Cervical Samples

    Science.gov (United States)

    Munoz, Marina; Camargo, Milena; Soto-De Leon, Sara C.; Sanchez, Ricardo; Parra, Diana; Pineda, Andrea C.; Sussmann, Otto; Perez-Prados, Antonio; Patarroyo, Manuel E.; Patarroyo, Manuel A.

    2013-01-01

    Infection, coinfection and type-specific human papillomavirus (HPV) distribution was evaluated in human immunodeficiency virus (HIV)-positive women from paired cervical and urine samples. Paired cervical and urine samples (n = 204) were taken from HIV-positive women for identifying HPV-DNA presence by using polymerase chain reaction (PCR) with three generic primer sets (GP5+/6+, MY09/11 and pU1M/2R). HPV-positive samples were typed for six high-risk HPV (HR-HPV) (HPV-16, -18, -31, -33, -45 and -58) and two low-risk (LR-HPV) (HPV-6/11) types. Agreement between paired sample results and diagnostic performance was evaluated. HPV infection prevalence was 70.6% in cervical and 63.2% in urine samples. HPV-16 was the most prevalent HPV type in both types of sample (66.7% in cervical samples and 62.0% in urine) followed by HPV-31(47.2%) in cervical samples and HPV-58 (35.7%) in urine samples. There was 55.4% coinfection (infection by more than one type of HPV) in cervical samples and 40.2% in urine samples. Abnormal Papanicolau smears were observed in 25.3% of the women, presenting significant association with HPV-DNA being identified in urine samples. There was poor agreement of cervical and urine sample results in generic and type-specific detection of HPV. Urine samples provided the best diagnosis when taking cytological findings as reference. In conclusion including urine samples could be a good strategy for ensuring adherence to screening programs aimed at reducing the impact of cervical cancer, since this sample is easy to obtain and showed good diagnostic performance. PMID:23418581

  20. Sample handling for mass spectrometric proteomic investigations of human urine.

    Science.gov (United States)

    Petri, Anette Lykke; Høgdall, Claus; Christensen, Ib Jarle; Simonsen, Anja Hviid; T'jampens, Davy; Hellmann, Marja-Leena; Kjaer, Susanne Krüger; Fung, Eric T; Høgdall, Estrid

    2008-09-01

    Because of its non-invasive sample collection method, human urine is an attractive biological material both for discovering biomarkers and for use in future screening trials for different diseases. Before urine can be used for these applications, standardized protocols for sample handling that optimize protein stability are required. In this explorative study, we examine the influence of different urine collection methods, storage temperatures, storage times, and repetitive freeze-thaw procedures on the protein profiles obtained by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Prospectively collected urine samples from 11 women were collected as either morning or midday specimens. The effects of storage temperature, time to freezing, and freeze-thaw cycles were assessed by calculating the number, intensity, and reproducibility of peaks visualized by SELDI-TOF-MS. On the CM10 array, 122 peaks were detected and 28 peaks were found to be significantly different between urine types, storage temperature and time to freezing. On the IMAC-Cu array, 65 peaks were detected and 1 peak was found to be significantly different according to time to freezing. No significant differences were demonstrated for freeze-thaw cycles. Optimal handling and storage conditions are necessary in clinical urine proteomic investigations. Collection of urine with a single and consistently performed protocol is needed to reduce analytical bias. Collecting only one urine type, which is stored for a limited period at 4°C until freezing at -80°C prior to analysis will provide the most stable profiles. Copyright © 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Self-sampling with HPV mRNA analyses from vagina and urine compared with cervical samples.

    Science.gov (United States)

    Asciutto, Katrin Christine; Ernstson, Avalon; Forslund, Ola; Borgfeldt, Christer

    2018-04-01

    In order to increase coverage in the organized cervical screening program, self-sampling with HPV analyses has been suggested. The aim was to compare human papillomavirus (HPV) mRNA detection in vaginal and urine self-collected samples with clinician-taken cervical samples and the corresponding clinician-taken histological specimens. Self-collected vaginal, urine and clinician-taken cervical samples were analyzed from 209 women with the Aptima mRNA assay (Hologic Inc, MA, USA). Cervical cytology, colposcopy, biopsy and/or the loop electrosurgical excision procedure (LEEP) were performed in every examination. The sensitivity of the HPV mRNA test in detecting high-grade squamous intraepithelial lesions (HSIL)/adenocarcinoma in situ (AIS)/cancer cases was as follows: for the vaginal self-samples 85.5% (95% CI; 75.0-92.8), the urinary samples 44.8% (95% CI; 32.6-57.4), and for routine cytology 81.7% (95% CI; 70.7-89.9). For the clinician-taken cervical HPV samples the sensitivity of the HPV mRNA test in detecting HSIL/AIS/cancer was 100.0% (95% CI; 94.9-100.0). The specificity of the HPV mRNA was similar for the clinician-taken cervical HPV samples and the self-samples: 49.0% vs. 48.1%. The urinary HPV samples had a specificity of 61.9% and cytology had a specificity of 93.3%. The sensitivity of the Aptima HPV mRNA test in detecting HSIL/AIS/cancer from vaginal self-samples was similar to that of routine cytology. The Aptima HPV mRNA vaginal self-sampling analysis may serve as a complement in screening programs. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. A method for estimating radioactive cesium concentrations in cattle blood using urine samples.

    Science.gov (United States)

    Sato, Itaru; Yamagishi, Ryoma; Sasaki, Jun; Satoh, Hiroshi; Miura, Kiyoshi; Kikuchi, Kaoru; Otani, Kumiko; Okada, Keiji

    2017-12-01

    In the region contaminated by the Fukushima nuclear accident, radioactive contamination of live cattle should be checked before slaughter. In this study, we establish a precise method for estimating radioactive cesium concentrations in cattle blood using urine samples. Blood and urine samples were collected from a total of 71 cattle on two farms in the 'difficult-to-return zone'. Urine 137 Cs, specific gravity, electrical conductivity, pH, sodium, potassium, calcium, and creatinine were measured and various estimation methods for blood 137 Cs were tested. The average error rate of the estimation was 54.2% without correction. Correcting for urine creatinine, specific gravity, electrical conductivity, or potassium improved the precision of the estimation. Correcting for specific gravity using the following formula gave the most precise estimate (average error rate = 16.9%): [blood 137 Cs] = [urinary 137 Cs]/([specific gravity] - 1)/329. Urine samples are faster to measure than blood samples because urine can be obtained in larger quantities and has a higher 137 Cs concentration than blood. These advantages of urine and the estimation precision demonstrated in our study, indicate that estimation of blood 137 Cs using urine samples is a practical means of monitoring radioactive contamination in live cattle. © 2017 Japanese Society of Animal Science.

  3. Reproducibility of NMR analysis of urine samples: impact of sample preparation, storage conditions, and animal health status.

    Science.gov (United States)

    Schreier, Christina; Kremer, Werner; Huber, Fritz; Neumann, Sindy; Pagel, Philipp; Lienemann, Kai; Pestel, Sabine

    2013-01-01

    Spectroscopic analysis of urine samples from laboratory animals can be used to predict the efficacy and side effects of drugs. This employs methods combining (1)H NMR spectroscopy with quantification of biomarkers or with multivariate data analysis. The most critical steps in data evaluation are analytical reproducibility of NMR data (collection, storage, and processing) and the health status of the animals, which may influence urine pH and osmolarity. We treated rats with a solvent, a diuretic, or a nephrotoxicant and collected urine samples. Samples were titrated to pH 3 to 9, or salt concentrations increased up to 20-fold. The effects of storage conditions and freeze-thaw cycles were monitored. Selected metabolites and multivariate data analysis were evaluated after (1)H NMR spectroscopy. We showed that variation of pH from 3 to 9 and increases in osmolarity up to 6-fold had no effect on the quantification of the metabolites or on multivariate data analysis. Storage led to changes after 14 days at 4°C or after 12 months at -20°C, independent of sample composition. Multiple freeze-thaw cycles did not affect data analysis. Reproducibility of NMR measurements is not dependent on sample composition under physiological or pathological conditions.

  4. Reproducibility of NMR Analysis of Urine Samples: Impact of Sample Preparation, Storage Conditions, and Animal Health Status

    Directory of Open Access Journals (Sweden)

    Christina Schreier

    2013-01-01

    Full Text Available Introduction. Spectroscopic analysis of urine samples from laboratory animals can be used to predict the efficacy and side effects of drugs. This employs methods combining 1H NMR spectroscopy with quantification of biomarkers or with multivariate data analysis. The most critical steps in data evaluation are analytical reproducibility of NMR data (collection, storage, and processing and the health status of the animals, which may influence urine pH and osmolarity. Methods. We treated rats with a solvent, a diuretic, or a nephrotoxicant and collected urine samples. Samples were titrated to pH 3 to 9, or salt concentrations increased up to 20-fold. The effects of storage conditions and freeze-thaw cycles were monitored. Selected metabolites and multivariate data analysis were evaluated after 1H NMR spectroscopy. Results. We showed that variation of pH from 3 to 9 and increases in osmolarity up to 6-fold had no effect on the quantification of the metabolites or on multivariate data analysis. Storage led to changes after 14 days at 4°C or after 12 months at −20°C, independent of sample composition. Multiple freeze-thaw cycles did not affect data analysis. Conclusion. Reproducibility of NMR measurements is not dependent on sample composition under physiological or pathological conditions.

  5. Simple DNA extraction of urine samples: Effects of storage temperature and storage time.

    Science.gov (United States)

    Ng, Huey Hian; Ang, Hwee Chen; Hoe, See Ying; Lim, Mae-Lynn; Tai, Hua Eng; Soh, Richard Choon Hock; Syn, Christopher Kiu-Choong

    2018-06-01

    Urine samples are commonly analysed in cases with suspected illicit drug consumption. In events of alleged sample mishandling, urine sample source identification may be necessary. A simple DNA extraction procedure suitable for STR typing of urine samples was established on the Promega Maxwell ® 16 paramagnetic silica bead platform. A small sample volume of 1.7mL was used. Samples were stored at room temperature, 4°C and -20°C for 100days to investigate the influence of storage temperature and time on extracted DNA quantity and success rate of STR typing. Samples stored at room temperature exhibited a faster decline in DNA yield with time and lower typing success rates as compared to those at 4°C and -20°C. This trend can likely be attributed to DNA degradation. In conclusion, this study presents a quick and effective DNA extraction protocol from a small urine volume stored for up to 100days at 4°C and -20°C. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Normalisation of spot urine samples to 24-h collection for assessment of exposure to uranium

    International Nuclear Information System (INIS)

    Marco, R.; Katorza, E.; Gonen, R.; German, U.; Tshuva, A.; Pelled, O.; Paz-tal, O.; Adout, A.; Karpas, Z.

    2008-01-01

    For dose assessment of workers at Nuclear Research Center Negev exposed to natural uranium, spot urine samples are analysed and the results are normalised to 24-h urine excretion based on 'standard' man urine volume of 1.6 l d -1 . In the present work, the urine volume, uranium level and creatinine concentration were determined in two or three 24-h urine collections from 133 male workers (319 samples) and 33 female workers (88 samples). Three volunteers provided urine spot samples from each voiding during a 24-h period and a good correlation was found between the relative level of creatinine and uranium in spot samples collected from the same individual. The results show that normalisation of uranium concentration to creatinine in a spot sample represents the 24-h content of uranium better than normalisation to the standard volume and may be used to reduce the uncertainty of dose assessment based on spot samples. (authors)

  7. Importance of Sample Preparation for Molecular Diagnosis of Lyme Borreliosis from Urine

    OpenAIRE

    Bergmann, A. R.; Schmidt, B. L.; Derler, A.-M.; Aberer, E.

    2002-01-01

    Urine PCR has been used for the diagnosis of Borrelia burgdorferi infection in recent years but has been abandoned because of its low sensitivity and the irreproducibility of the results. Our study aimed to analyze technical details related to sample preparation and detection methods. Crucial for a successful urine PCR were (i) avoidance of the first morning urine sample; (ii) centrifugation at 36,000 × g; and (iii) the extraction method, with only DNAzol of the seven different extraction met...

  8. Standardization of method to determine 241Pu in urine samples by liquid scintillation analyzer

    International Nuclear Information System (INIS)

    Raveendran, Nanda; Rao, D.D.; Yadav, J.R.; Baburajan, A.

    2015-01-01

    As a part of radiation protection programme, occupational workers of fuel reprocessing plant are checked for internal contamination by analyzing urine samples periodically. Urine samples are analyzed to determine 239+240 Pu and 238 Pu by using standard conventional method and are counted by alpha spectrometry. 241 Pu is also one of the contaminant present in the urine sample of radiation workers. It is a low beta emitter with E max 21 keV. A methodology for the determination of this nuclide was standardized by using radiochemical analysis followed by Liquid Scintillation Counting. The method was tested and found suitable for the determination of 241 Pu in urine sample for the assessment of Committed Effective Dose (CED). (author)

  9. Experimental evaluation of the detection threshold of uranium in urine samples

    International Nuclear Information System (INIS)

    Ferreyra, M. D.; Suarez Mendez, Sebastian; Tossi, Mirta H.

    1999-01-01

    The routine internal dosimetric tests for nuclear installations workers includes the determination of uranium in urine. The analysis is carried out, after chemical treatment, by UV fluorometry, comparing the results with urine blank samples from workers not exposed professionally to contamination. The fluctuation of the results of the uranium content in the blank samples greatly affects the determinations. In 30 blank samples the uranium content was determined and the results were evaluated by three calculation methods: 1) The procedure recommended by IUPAC; 2) The graphical method; 3) and The error propagation method. The last one has been adopted for the calculation of the detection threshold. (authors)

  10. Assessment of radioactivity for 24 hours urine sample depending on correction factor by using creatinine

    International Nuclear Information System (INIS)

    Kharita, M. H.; Maghrabi, M.

    2006-09-01

    Assessment of intake and internal does requires knowing the amount of radioactivity in 24 hours urine sample, sometimes it is difficult to get 24 hour sample because this method is not comfortable and in most cases the workers refuse to collect this amount of urine. This work focuses on finding correction factor of 24 hour sample depending on knowing the amount of creatinine in the sample whatever the size of this sample. Then the 24 hours excretion of radionuclide is calculated assuming the average creatinine excretion rate is 1.7 g per 24 hours, based on the amount of activity and creatinine in the urine sample. Several urine sample were collected from occupationally exposed workers the amount and ratios of creatinine and activity in these samples were determined, then normalized to 24 excretion of radionuclide. The average chemical recovery was 77%. It should be emphasized that this method should only be used if a 24 hours sample was not possible to collect. (author)

  11. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    Science.gov (United States)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  12. Estimation of uranium isotope in urine samples using extraction chromatography resin

    International Nuclear Information System (INIS)

    Thakur, Smita S.; Yadav, J.R.; Rao, D.D.

    2012-01-01

    Internal exposure monitoring for alpha emitting radionuclides is carried out by bioassay samples analysis. For occupational radiation workers handling uranium in reprocessing or fuel fabrication facilities, there exists a possibility of internal exposure and urine assay is the preferred method for monitoring such exposure. Estimation of lower concentration of uranium at mBq level by alpha spectrometry requires preconcentration and its separation from large volume of urine sample. For this purpose, urine samples collected from non radiation workers were spiked with 232 U tracer at mBq level to estimate the chemical yield. Uranium in urine sample was pre-concentrated by calcium phosphate coprecipitation and separated by extraction chromatography resin U/TEVA. In this resin extractant was DAAP (Diamylamylphosphonate) supported on inert Amberlite XAD-7 support material. After co-precipitation, precipitate was centrifuged and dissolved in 10 ml of 1M Al(NO 3 ) 3 prepared in 3M HNO 3 . The sample thus prepared was loaded on extraction chromatography resin, pre-conditioned with 10 ml of 3M HNO 3 . Column was washed with 10 ml of 3M HNO 3 . Column was again rinsed with 5 ml of 9M HCl followed by 20 ml of 0.05 M oxalic acid prepared in 5M HCl to remove interference due to Th and Np if present in the sample. Uranium was eluted from U/TEVA column with 15 ml of 0.01M HCl. The eluted uranium fraction was electrodeposited on stainless steel planchet and counted by alpha spectrometry for 360000 sec. Approximate analysis time involved from sample loading to stripping is 2 hours when compared with the time involved of 3.5 hours by conventional ion exchange method. Seven urine samples from non radiation worker were radio chemically analyzed by this technique and the radiochemical yield was found in the range of 69-91 %. Efficacy of this method against conventional anion exchange technique earlier standardized at this laboratory is also being highlighted. Minimum detectable activity

  13. New sorbent materials for selective extraction of cocaine and benzoylecgonine from human urine samples.

    Science.gov (United States)

    Bujak, Renata; Gadzała-Kopciuch, Renata; Nowaczyk, Alicja; Raczak-Gutknecht, Joanna; Kordalewska, Marta; Struck-Lewicka, Wiktoria; Waszczuk-Jankowska, Małgorzata; Tomczak, Ewa; Kaliszan, Michał; Buszewski, Bogusław; Markuszewski, Michał J

    2016-02-20

    An increase in cocaine consumption has been observed in Europe during the last decade. Benzoylecgonine, as a main urinary metabolite of cocaine in human, is so far the most reliable marker of cocaine consumption. Determination of cocaine and its metabolite in complex biological samples as urine or blood, requires efficient and selective sample pretreatment. In this preliminary study, the newly synthesized sorbent materials were proposed for selective extraction of cocaine and benzoylecgonine from urine samples. Application of these sorbent media allowed to determine cocaine and benzoylecgonine in urine samples at the concentration level of 100ng/ml with good recovery values as 81.7%±6.6 and 73.8%±4.2, respectively. The newly synthesized materials provided efficient, inexpensive and selective extraction of both cocaine and benzoylecgonine from urine samples, which can consequently lead to an increase of the sensitivity of the current available screening diagnostic tests. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Lead Quantification in Urine Samples of Athletes by Coupling DLLME with UV-Vis Spectrophotometry.

    Science.gov (United States)

    Faraji, Hakim; Helalizadeh, Masoumeh

    2017-04-01

    Urine lead level is one of the most employed measures of lead exposure and risk. The urine samples used in this study were obtained from ten healthy male cyclists. Dispersive liquid-liquid microextraction combined with ultraviolet and visible spectrophotometry was utilized for preconcentration, extraction, and determination of lead in urine samples. Optimization of the independent variables was carried out based on chemometric methods in three steps. According to the screening and optimization study, 133 μL of CCl 4 (extracting solvent), 1.34 mL ethanol (dispersing solvent), pH 2.0, 0.00 % of salt, and 0.1 % O,O-diethyl dithiophosphoric (chelating agent) were used as the optimum independent variables for microextraction and determination of lead. Under the optimized conditions, R 2 was 0.9991, and linearity range was 0.01-100 μg L -1 . Precision was evaluated in terms of repeatability and intermediate precision, with relative standard deviations being <9.1 and <15.3 %, respectively. The accuracy was estimated using urine samples of cyclists as real samples and it was confirmed. The relative error of ≤5 % was considered significant in the method specificity study. The lead concentration mean for the cyclists was 3.79 μg L -1 in urine samples. As a result, the proposed method is a robust technique to quantify lead concentrations higher than 11.6 ng L -1 in urine samples.

  15. Solvent-assisted dispersive solid-phase extraction: A sample preparation method for trace detection of diazinon in urine and environmental water samples.

    Science.gov (United States)

    Aladaghlo, Zolfaghar; Fakhari, Alireza; Behbahani, Mohammad

    2016-09-02

    In this research, a sample preparation method termed solvent-assisted dispersive solid-phase extraction (SA-DSPE) was applied. The used sample preparation method was based on the dispersion of the sorbent into the aqueous sample to maximize the interaction surface. In this approach, the dispersion of the sorbent at a very low milligram level was received by inserting a solution of the sorbent and disperser solvent into the aqueous sample. The cloudy solution created from the dispersion of the sorbent in the bulk aqueous sample. After pre-concentration of the diazinon, the cloudy solution was centrifuged and diazinon in the sediment phase dissolved in ethanol and determined by gas chromatography-flame ionization detector. Under the optimized conditions (pH of solution=7.0, Sorbent: benzophenone, 2%, Disperser solvent: ethanol, 500μL, Centrifuge: centrifuged at 4000rpm for 3min), the method detection limit for diazinon was 0.2, 0.3, 0.3 and 0.3μgL(-1) for distilled water, lake water, waste water and urine sample, respectively. Furthermore, the pre-concentration factor was 363.8, 356.1, 360.7 and 353.38 in distilled water, waste water, lake water and urine sample, respectively. SA-DSPE was successfully used for trace monitoring of diazinon in urine, lake and waste water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Reliable Quantification of the Potential for Equations Based on Spot Urine Samples to Estimate Population Salt Intake

    DEFF Research Database (Denmark)

    Huang, Liping; Crino, Michelle; Wu, Jason Hy

    2016-01-01

    to a standard format. Individual participant records will be compiled and a series of analyses will be completed to: (1) compare existing equations for estimating 24-hour salt intake from spot urine samples with 24-hour urine samples, and assess the degree of bias according to key demographic and clinical......BACKGROUND: Methods based on spot urine samples (a single sample at one time-point) have been identified as a possible alternative approach to 24-hour urine samples for determining mean population salt intake. OBJECTIVE: The aim of this study is to identify a reliable method for estimating mean...... population salt intake from spot urine samples. This will be done by comparing the performance of existing equations against one other and against estimates derived from 24-hour urine samples. The effects of factors such as ethnicity, sex, age, body mass index, antihypertensive drug use, health status...

  17. Reproducibility of NMR Analysis of Urine Samples: Impact of Sample Preparation, Storage Conditions, and Animal Health Status

    OpenAIRE

    Schreier, Christina; Kremer, Werner; Huber, Fritz; Neumann, Sindy; Pagel, Philipp; Lienemann, Kai; Pestel, Sabine

    2013-01-01

    Introduction. Spectroscopic analysis of urine samples from laboratory animals can be used to predict the efficacy and side effects of drugs. This employs methods combining 1H NMR spectroscopy with quantification of biomarkers or with multivariate data analysis. The most critical steps in data evaluation are analytical reproducibility of NMR data (collection, storage, and processing) and the health status of the animals, which may influence urine pH and osmolarity. Methods. We treated rats wit...

  18. Procedure for determination of alpha emitters in urine and dregs samples

    International Nuclear Information System (INIS)

    Serdeiro, Nelida H.

    2005-01-01

    The purpose of this work is to establish the procedure for the identification and quantification of emitting alpha radionuclides in urine and dregs samples. This procedure are applied to all laboratories of the countries of the Project ARCAL LXXVII that determinate alpha emitting radionuclides in biological samples for biological assessment [es

  19. Urine stability and steroid profile: towards a screening index of urine sample degradation for anti-doping purpose.

    Science.gov (United States)

    Mazzarino, Monica; Abate, Maria Gabriella; Alocci, Roberto; Rossi, Francesca; Stinchelli, Raffaella; Molaioni, Francesco; de la Torre, Xavier; Botrè, Francesco

    2011-01-10

    The presence of microorganisms in urine samples, under favourable conditions of storage and transportation, may alter the concentration of steroid hormones, thus altering the correct evaluation of the urinary steroid profile in doping control analysis. According to the rules of the World Anti-Doping Agency (WADA technical document TD2004 EAAS), a testosterone deconjugation higher than 5% and the presence of 5α-androstane-3,17-dione and 5β-androstane-3,17-dione in the deconjugated fraction, are reliable indicators of urine degradation. The determination of these markers would require an additional quantitative analysis since the steroids screening analysis, in anti-doping laboratories, is performed in the total (free+conjugated) fraction. The aim of this work is therefore to establish reliable threshold values for some representative compounds (namely 5α-androstane-3,17-dione and 5β-androstane-3,17-dione) in the total fraction in order to predict directly at the screening stage the potential microbial degradation of the urine samples. Preliminary evidence on the most suitable degradation indexes has been obtained by measuring the urinary concentration of testosterone, epitestosterone, 5α-androstane-3,17-dione and 5β-androstane-3,17-dione by gas chromatography-mass spectrometric every day for 15 days in the deconjugated, glucuronide and total fraction of 10 pools of urines from 60 healthy subjects, stored under different pH and temperature conditions, and isolating the samples with one or more markers of degradation according to the WADA technical document TD2004EAAS. The threshold values for 5α-androstane-3,17-dione and 5β-androstane-3,17-dione were therefore obtained correlating the testosterone deconjugation rate with the urinary concentrations of 5α-androstane-3,17-dione and 5β-androstane-3,17-dione in the total fraction. The threshold values suggested as indexes of urine degradation in the total fraction were: 10 ng mL(-1) for 5α-androstane-3,17-dione

  20. Urine storage under refrigeration preserves the sample in chemical, cellularity and bacteriuria analysis of ACS

    Directory of Open Access Journals (Sweden)

    Karen Cristina Barcellos Ribeiro

    2013-12-01

    Full Text Available INTRODUCTION: The analysis of urine abnormal constituents and sediment (ACS comprises tests of great diagnostic and prognostic value in clinical practice. When the analysis of ACS cannot be performed within two hours after collection, the sample must be preserved in order to avoid pre-analytical interferences. Refrigeration is the most applied technique due to its cost effectiveness. Moreover, it presents fewer inconveniences when compared to chemical preservation. However, changes in ACS may also occur in samples under refrigeration. OBJECTIVE: To analyze the influence of refrigeration at 2 to 8ºC on the storage of urine samples within 24 hours. MATERIAL AND METHOD: A total of 80 urine samples were selected from patients admitted at Universidade Federal de Juiz de Fora (UFJF university hospital, which were tested for ACS at room temperature and stored under refrigeration for 6, 12 and 24 hours. RESULTS: The results showed that refrigeration proved to be effective when compared to samples kept at room temperature, inasmuch as the physical, chemical, microbial and cellularity features were preserved. Nevertheless, crystalluria was present after a 6- hour storage period. CONCLUSION: The tests revealed that cooling preserved cellularity and chemical characteristics of urine samples for up to 12 hours. Nonetheless, the precipitation of crystals was evident in this storage method. Thus, the possible consequences of storing urine samples for ACS test under these conditions should be included in the analysis report.

  1. Trace element analysis of whole blood and urine samples of diabetic patients

    Energy Technology Data Exchange (ETDEWEB)

    Lodhi, A S; Rashiduzzaman Khan, M [Atomic Energy Organization of Iran, Teheran. Nuclear Research Centre

    1979-01-01

    A number of samples of whole blood, and urine from diabetic and non-diabetic persons have been analyzed for their trace elemental contents using the proton-induced X-ray emission. The elemental contents of the diabetic and non-diabetic samples are compared.

  2. A Comparison of 4- and 24-Hour Urine Samples for the Diagnosis of Proteinuria in Pregnancy

    Directory of Open Access Journals (Sweden)

    Afsane Amirabi

    2011-09-01

    Full Text Available Background: Preeclampsia is a serious complication of pregnancy, and it is vital to diagnosis the condition as early as possible. Proteinuria is an important symptom of preeclampsia, and repeated urine analysis to screen for the condition is part of the standard antenatal care. The purpose of this study was to determine the correlation between 4- and 24-hour urine total protein values to examine whether the 4-hour urine samples could be used for the diagnosis of proteinuria in hypertensive disorders of pregnancy. Methods: A cross-sectional study was performed on 110 pregnant (after gestational week 20 of pregnancy patients who were hypertensive (blood pressure ≥140/90 mmHg and had proteinuria as defined by positive urinary protein of at least 1+ in dipstick. Patients' urine samples were collected over 24 hours; the first 4 hours were collected separately from the next 20-hours. Patients, who did not collect the 24-hour urine, were excluded from the study. One hundred patients met the criteria, and were included in the study. The urine volume, total protein and creatinine levels of 4- and 24-hours samples were measured. The correlation between 4-hour and 24-hour samples was examined using Pearson correlation test. Results: Of the 100 patients, 42 had no proteinuria, 44 had mild proteinuria, and 14 had severe proteinuria. The urine protein values of 4-hour samples correlated with those of the 24-hours samples for patients with mild and severe forms of the disease (P<0.001, r=0.86. Conclusion: This study showed there was a correlation between 4-hour and 24-hour urine proteins. The finding indicates that a random 4-hour sample might be used for the initial assessment of proteinuria

  3. Long-term frozen storage of urine samples: a trouble to get PCR results in Schistosoma spp. DNA detection?

    Science.gov (United States)

    Fernández-Soto, Pedro; Velasco Tirado, Virginia; Carranza Rodríguez, Cristina; Pérez-Arellano, José Luis; Muro, Antonio

    2013-01-01

    Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples' storage or conditions for handling and DNA preservation and extraction methods. We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patients urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template. Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA method of extraction used.

  4. Evaluation of Equations for Predicting 24-Hour Urinary Sodium Excretion from Casual Urine Samples in Asian Adults.

    Science.gov (United States)

    Whitton, Clare; Gay, Gibson Ming Wei; Lim, Raymond Boon Tar; Tan, Linda Wei Lin; Lim, Wei-Yen; van Dam, Rob M

    2016-08-01

    The collection of 24-h urine samples for the estimation of sodium intake is burdensome, and the utility of spot urine samples in Southeast Asian populations is unclear. We aimed to assess the validity of prediction equations with the use of spot urine concentrations. A sample of 144 Singapore residents of Chinese, Malay, and Indian ethnicity aged 18-79 y were recruited from the Singapore Health 2 Study conducted in 2014. Participants collected urine for 24 h in multiple small bottles on a single day. To determine the optimal collection time for a spot urine sample, a 1-mL sample was taken from a random bottle collected in the morning, afternoon, and evening. Published equations and a newly derived equation were used to predict 24-h sodium excretion from spot urine samples. The mean ± SD concentration of sodium from the 24-h urine sample was 125 ± 53.4 mmol/d, which is equivalent to 7.2 ± 3.1 g salt. Bland-Altman plots showed good agreement at the group level between estimated and actual 24-h sodium excretion, with biases for the morning period of -3.5 mmol (95% CI: -14.8, 7.8 mmol; new equation) and 1.46 mmol (95% CI: -10.0, 13.0 mmol; Intersalt equation). A larger bias of 25.7 mmol (95% CI: 12.2, 39.3 mmol) was observed for the Tanaka equation in the morning period. The prediction accuracy did not differ significantly for spot urine samples collected at different times of the day or at a random time of day (P = 0.11-0.76). This study suggests that the application of both our own newly derived equation and the Intersalt equation to spot urine concentrations may be useful in predicting group means for 24-h sodium excretion in urban Asian populations. © 2016 American Society for Nutrition.

  5. Size-exclusion chromatography-based enrichment of extracellular vesicles from urine samples

    Directory of Open Access Journals (Sweden)

    Inés Lozano-Ramos

    2015-05-01

    Full Text Available Renal biopsy is the gold-standard procedure to diagnose most of renal pathologies. However, this invasive method is of limited repeatability and often describes an irreversible renal damage. Urine is an easily accessible fluid and urinary extracellular vesicles (EVs may be ideal to describe new biomarkers associated with renal pathologies. Several methods to enrich EVs have been described. Most of them contain a mixture of proteins, lipoproteins and cell debris that may be masking relevant biomarkers. Here, we evaluated size-exclusion chromatography (SEC as a suitable method to isolate urinary EVs. Following a conventional centrifugation to eliminate cell debris and apoptotic bodies, urine samples were concentrated using ultrafiltration and loaded on a SEC column. Collected fractions were analysed by protein content and flow cytometry to determine the presence of tetraspanin markers (CD63 and CD9. The highest tetraspanin content was routinely detected in fractions well before the bulk of proteins eluted. These tetraspanin-peak fractions were analysed by cryo-electron microscopy (cryo-EM and nanoparticle tracking analysis revealing the presence of EVs.When analysed by sodium dodecyl sulphate–polyacrylamide gel electrophoresis, tetraspanin-peak fractions from urine concentrated samples contained multiple bands but the main urine proteins (such as Tamm–Horsfall protein were absent. Furthermore, a preliminary proteomic study of these fractions revealed the presence of EV-related proteins, suggesting their enrichment in concentrated samples. In addition, RNA profiling also showed the presence of vesicular small RNA species.To summarize, our results demonstrated that concentrated urine followed by SEC is a suitable option to isolate EVs with low presence of soluble contaminants. This methodology could permit more accurate analyses of EV-related biomarkers when further characterized by -omics technologies compared with other approaches.

  6. Efficient sample preparation method based on solvent-assisted dispersive solid-phase extraction for the trace detection of butachlor in urine and waste water samples.

    Science.gov (United States)

    Aladaghlo, Zolfaghar; Fakhari, Alireza; Behbahani, Mohammad

    2016-10-01

    In this work, an efficient sample preparation method termed solvent-assisted dispersive solid-phase extraction was applied. The used sample preparation method was based on the dispersion of the sorbent (benzophenone) into the aqueous sample to maximize the interaction surface. In this approach, the dispersion of the sorbent at a very low milligram level was achieved by inserting a solution of the sorbent and disperser solvent into the aqueous sample. The cloudy solution created from the dispersion of the sorbent in the bulk aqueous sample. After pre-concentration of the butachlor, the cloudy solution was centrifuged and butachlor in the sediment phase dissolved in ethanol and determined by gas chromatography with flame ionization detection. Under the optimized conditions (solution pH = 7.0, sorbent: benzophenone, 2%, disperser solvent: ethanol, 500 μL, centrifuged at 4000 rpm for 3 min), the method detection limit for butachlor was 2, 3 and 3 μg/L for distilled water, waste water, and urine sample, respectively. Furthermore, the preconcentration factor was 198.8, 175.0, and 174.2 in distilled water, waste water, and urine sample, respectively. Solvent-assisted dispersive solid-phase extraction was successfully used for the trace monitoring of butachlor in urine and waste water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Evaluation of the BD Vacutainer Plus Urine C&S Preservative Tubes compared with nonpreservative urine samples stored at 4°C and room temperature.

    Science.gov (United States)

    Eisinger, Stephen W; Schwartz, Matthew; Dam, Lisa; Riedel, Stefan

    2013-09-01

    The stability of urine specimens submitted for culture remains a challenge for many laboratories because of delays in specimen transport. We evaluated the usefulness of BD Vacutainer Plus Urine C&S Preservative Tube in ensuring specimen stability. Clinical urine specimens collected in sterile collection cups (n = 110) were plated onto sheep blood and MacConkey agar following standard laboratory procedures guidelines. Thereafter, specimens were divided into 3 storage conditions: nonpreservative, refrigerated; nonpreservative, room temperature (RT); BD Vacutainer Plus Urine C&S Preservative Tube, RT. For each sample type, additional cultures were set up at 2, 4, 24, and 48 hours. Initially, 18 specimens had no growth, 32 showed mixed skin flora, and 60 yielded at least 1 uropathogen. Increased colony counts of uropathogens were observed for nonpreserved urine samples stored at RT; these changes were statistically significant. Minor differences between refrigerated urine samples and BD Vacutainer Plus Urine C&S Preservative Tube samples were seen but were not statistically significant. The use of preservative-containing collection tubes is desirable to ensure specimen stability when prompt processing or refrigeration is not feasible.

  8. Metabolomic analysis of urine samples by UHPLC-QTOF-MS: Impact of normalization strategies.

    Science.gov (United States)

    Gagnebin, Yoric; Tonoli, David; Lescuyer, Pierre; Ponte, Belen; de Seigneux, Sophie; Martin, Pierre-Yves; Schappler, Julie; Boccard, Julien; Rudaz, Serge

    2017-02-22

    Among the various biological matrices used in metabolomics, urine is a biofluid of major interest because of its non-invasive collection and its availability in large quantities. However, significant sources of variability in urine metabolomics based on UHPLC-MS are related to the analytical drift and variation of the sample concentration, thus requiring normalization. A sequential normalization strategy was developed to remove these detrimental effects, including: (i) pre-acquisition sample normalization by individual dilution factors to narrow the concentration range and to standardize the analytical conditions, (ii) post-acquisition data normalization by quality control-based robust LOESS signal correction (QC-RLSC) to correct for potential analytical drift, and (iii) post-acquisition data normalization by MS total useful signal (MSTUS) or probabilistic quotient normalization (PQN) to prevent the impact of concentration variability. This generic strategy was performed with urine samples from healthy individuals and was further implemented in the context of a clinical study to detect alterations in urine metabolomic profiles due to kidney failure. In the case of kidney failure, the relation between creatinine/osmolality and the sample concentration is modified, and relying only on these measurements for normalization could be highly detrimental. The sequential normalization strategy was demonstrated to significantly improve patient stratification by decreasing the unwanted variability and thus enhancing data quality. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Development of a new protocol for rapid bacterial identification and susceptibility testing directly from urine samples.

    Science.gov (United States)

    Zboromyrska, Y; Rubio, E; Alejo, I; Vergara, A; Mons, A; Campo, I; Bosch, J; Marco, F; Vila, J

    2016-06-01

    The current gold standard method for the diagnosis of urinary tract infections (UTI) is urine culture that requires 18-48 h for the identification of the causative microorganisms and an additional 24 h until the results of antimicrobial susceptibility testing (AST) are available. The aim of this study was to shorten the time of urine sample processing by a combination of flow cytometry for screening and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for bacterial identification followed by AST directly from urine. The study was divided into two parts. During the first part, 675 urine samples were processed by a flow cytometry device and a cut-off value of bacterial count was determined to select samples for direct identification by MALDI-TOF-MS at ≥5 × 10(6) bacteria/mL. During the second part, 163 of 1029 processed samples reached the cut-off value. The sample preparation protocol for direct identification included two centrifugation and two washing steps. Direct AST was performed by the disc diffusion method if a reliable direct identification was obtained. Direct MALDI-TOF-MS identification was performed in 140 urine samples; 125 of the samples were positive by urine culture, 12 were contaminated and 3 were negative. Reliable direct identification was obtained in 108 (86.4%) of the 125 positive samples. AST was performed in 102 identified samples, and the results were fully concordant with the routine method among 83 monomicrobial infections. In conclusion, the turnaround time of the protocol described to diagnose UTI was about 1 h for microbial identification and 18-24 h for AST. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  10. A rapid method for estimation of Pu-isotopes in urine samples using high volume centrifuge.

    Science.gov (United States)

    Kumar, Ranjeet; Rao, D D; Dubla, Rupali; Yadav, J R

    2017-07-01

    The conventional radio-analytical technique used for estimation of Pu-isotopes in urine samples involves anion exchange/TEVA column separation followed by alpha spectrometry. This sequence of analysis consumes nearly 3-4 days for completion. Many a times excreta analysis results are required urgently, particularly under repeat and incidental/emergency situations. Therefore, there is need to reduce the analysis time for the estimation of Pu-isotopes in bioassay samples. This paper gives the details of standardization of a rapid method for estimation of Pu-isotopes in urine samples using multi-purpose centrifuge, TEVA resin followed by alpha spectrometry. The rapid method involves oxidation of urine samples, co-precipitation of plutonium along with calcium phosphate followed by sample preparation using high volume centrifuge and separation of Pu using TEVA resin. Pu-fraction was electrodeposited and activity estimated using 236 Pu tracer recovery by alpha spectrometry. Ten routine urine samples of radiation workers were analyzed and consistent radiochemical tracer recovery was obtained in the range 47-88% with a mean and standard deviation of 64.4% and 11.3% respectively. With this newly standardized technique, the whole analytical procedure is completed within 9h (one working day hour). Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Modulated Raman spectroscopy for enhanced identification of bladder tumor cells in urine samples.

    Science.gov (United States)

    Canetta, Elisabetta; Mazilu, Michael; De Luca, Anna Chiara; Carruthers, Antonia E; Dholakia, Kishan; Neilson, Sam; Sargeant, Harry; Briscoe, Tina; Herrington, C Simon; Riches, Andrew C

    2011-03-01

    Standard Raman spectroscopy (SRS) is a noninvasive technique that is used in the biomedical field to discriminate between normal and cancer cells. However, the presence of a strong fluorescence background detracts from the use of SRS in real-time clinical applications. Recently, we have reported a novel modulated Raman spectroscopy (MRS) technique to extract the Raman spectra from the background. In this paper, we present the first application of MRS to the identification of human urothelial cells (SV-HUC-1) and bladder cancer cells (MGH) in urine samples. These results are compared to those obtained by SRS. Classification using the principal component analysis clearly shows that MRS allows discrimination between Raman spectra of SV-HUC-1 and MGH cells with high sensitivity (98%) and specificity (95%). MRS is also used to distinguish between SV-HUC-1 and MGH cells after exposure to urine for up to 6 h. We observe a marked change in the MRS of SV-HUC-1 and MGH cells with time in urine, indicating that the conditions of sample collection will be important for the application of this methodology to clinical urine samples.

  12. Long-term frozen storage of urine samples: a trouble to get PCR results in Schistosoma spp. DNA detection?

    Directory of Open Access Journals (Sweden)

    Pedro Fernández-Soto

    Full Text Available BACKGROUND: Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples' storage or conditions for handling and DNA preservation and extraction methods. METHODOLOGY/PRINCIPAL FINDINGS: We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patients urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template. CONCLUSIONS/SIGNIFICANCE: Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA

  13. Filter paper saturated by urine sample in metabolic disorders detection by proton magnetic resonance spectroscopy.

    Science.gov (United States)

    Blasco, Hélène; Garrigue, Marie-Ange; De Vos, Aymeric; Antar, Catherine; Labarthe, François; Maillot, François; Andres, Christian R; Nadal-Desbarats, Lydie

    2010-02-01

    NMR spectroscopy of urine samples is able to diagnose many inborn errors of metabolism (IEM). However, urinary metabolites have a poor stability, requiring special care for routine analysis (storage of urine at -20 or -80 degrees C, fast transport). The aim of our study was to investigate the reliability of dried urine filter paper for urine storage and transport and to evaluate the ability of NMR to detect several IEM using this method. Urine samples from five healthy subjects were analyzed by (1)H NMR following different storage conditions (-20 vs 4 degrees C vs dried on filter paper) and at different time points (24 h, 48 h, 96 h, and 7 days). Urine pattern of fresh urine was considered as a reference. We analyzed the conservation of some amino acids and organic acids using Bland and Altman plot with intraclass correlation coefficient determination. Then, we evaluated the use of filter paper to detect four different IEM (methylmalonic and isovaleric acidurias, ornithine transcarbamylase deficiency, and cystinuria). Analysis of urine samples from healthy subjects revealed a high stability of studied molecules (ICC > 0.8) even after 7 days of storage on filter paper. Moreover, an excellent preservation of metabolites specifically accumulated in IEM was observed when analysis of dried urine filter paper was compared to fresh urine (coefficient of variation storage of dried urine on filter paper is reliable for (1)H NMR spectroscopy analysis. Preservation of urine molecules over time using that method is convenient for routine clinical practice.

  14. Impact of cleaning before obtaining midstream urine samples from children

    DEFF Research Database (Denmark)

    Lytzen, Rebekka; Knudsen, Jenny Dahl; Ladelund, Steen

    2014-01-01

    INTRODUCTION: Microbiological documentation of one uropathogenic bacterium in significant numbers in urine from patients with typical symptoms is the gold standard for diagnosing urinary tract infection (UTI). Cleaning before collecting midstream urine (MSU) is reported not to reduce the risk...... of contaminating the sample and was therefore omitted at Hvidovre Hospital as from the autumn of 2006. We evaluate if no cleaning increased the risk of contamination in the Department of Paediatrics. MATERIAL AND METHODS: A total of 1,858 patients aged 0-15 years who were suspected of UTI delivered two MSUs within...

  15. The examination of urine samples for pathogenic microbes by the luciferase assay for ATP. 1: The effect of the presence of fungi, fungal like bacteria and kidney cells in urine samples

    Science.gov (United States)

    Bush, V. N.

    1973-01-01

    A method for accurately determining urinary tract infections in man is introduced. The method is based on adenosine triphosphate (ATP) concentration in urine samples after removing nonbacterial ATP. Adenosine triphosphate concentration is measured from the bioluminescent reaction of luciferase when mixed with ATP. An examination was also made of the effectiveness of rupturing agents on monkey kidney cells Candia albicans, a Rhodotorula species, and a Streptomyces species in determining whether these cells could contribute ATP to the bacterial ATP value of a urine sample.

  16. Introduction of sample tubes with sodium azide as a preservative for ethyl glucuronide in urine.

    Science.gov (United States)

    Luginbühl, Marc; Weinmann, Wolfgang; Al-Ahmad, Ali

    2017-09-01

    Ethyl glucuronide (EtG) is a direct alcohol marker, which is widely used for clinical and forensic applications, mainly for abstinence control. However, the instability of EtG in urine against bacterial degradation or the post-collectional synthesis of EtG in contaminated samples may cause false interpretation of EtG results in urine samples. This study evaluates the potential of sodium azide in tubes used for urine collection to hinder degradation of ethyl glucuronide by bacterial metabolism taking place during growth of bacterial colonies. The tubes are part of a commercial oral fluid collection device. The sampling system was tested with different gram-positive and gram-negative bacterial species previously observed in urinary tract infections, such as Escherichia coli, Staphylococcus aureus, Enterecoccus faecalis, Staphylococcus epidermidis, Klebsiella pneumoniae, Enterobacter cloacae, and Pseudomonas aeruginosa. Inhibition of bacterial growth by sodium azide, resulting in lower numbers of colony forming units compared to control samples, was observed for all tested bacterial species. To test the prevention of EtG degradation by the predominant pathogen in urinary tract infection, sterile-filtered urine and deficient medium were spiked with EtG, and inoculated with E. coli prior to incubation for 4 days at 37 °C in tubes with and without sodium azide. Samples were collected every 24 hours, during four consecutive days, whereby the colony forming units (CFU) were counted on Columbia blood agar plates, and EtG was analyzed by LC-MS/MS. As expected, EtG degradation was observed when standard polypropylene tubes were used for the storage of contaminated samples. However, urine specimens collected in sodium azide tubes showed no or very limited bacterial growth and no EtG degradation. As a conclusion, sodium azide is useful to reduce bacterial growth of gram-negative and gram-positive bacteria. It inhibits the degradation of EtG by E. coli and can be used for

  17. The method of urine sampling is not a valid predictor for vesicoureteral reflux in children after febrile urinary tract infections.

    Science.gov (United States)

    Haid, Bernhard; Roesch, Judith; Strasser, Christa; Oswald, Josef

    2017-10-01

    The likelihood of detecting vesicoureteral reflux (VUR) after febrile urinary tract infections (UTI) in children logically should correlate with the correct diagnosis of the UTI. Beneath the unspecific symptoms of fever urine analysis is the main diagnostic criterion for the exact diagnosis of febrile UTIs in children. Use of inadequate urine sampling techniques during diagnosis may lead to impaired accuracy in UTI diagnosis. This could lead to the assumption that children, having diagnosed their UTI by the use of possibly inadequate urine sampling techniques should not be evaluated as consequently compared to those, where the diagnosis relied on sterile urine sampling techniques. We hypothesized that children with possibly contaminated urine samples during the initial diagnosis may show a lower rate of VUR in subsequent VCUGs because of a wrong diagnosis initially compared to children, where accurate urine sampling techniques were used. Between 2009 and 2014, a total of 555 patients underwent a primary VCUG at our department indicated because of febrile UTIs. Patients with urine collection methods other than bag urine and catheter/suprapubic aspiration (SPA) were excluded from this study (mid-stream urine, potty urine, n = 149). We evaluated 402 patients (male/female 131/271, mean age 1.91 years), VUR rates and grades were compared between patients where urine was sampled by the use of a urine bag only at the time of diagnosis (n = 296, 73.6%) and those where sterile urine sampling (catheter, suprapubic puncture) was performed (n = 106, 26.3%). 4 patients were excluded due to equivocal data on urine sampling. VUR rate in children after sterile urine sampling using a catheter or SPA accounted to 31.1%. In those where urine samples acquired by the use of urine bags were used, 33.7% showed VUR on subsequent VCUG (p = 0.718). There were no significant differences as to VUR grades or gender, although VUR was much more commonly diagnosed in female patients (37

  18. Natural radionuclides in urine- and faeces samples; Natuerliche Radionuklide in Urin- und Stuhlproben

    Energy Technology Data Exchange (ETDEWEB)

    Froning, M.; Burow, M.; Ennen, R.; Hoelters, A.; Laumen-Sentis, S.; Zoriy, M. [Forschungszentrum Juelich GmbH (Germany). Geschaeftsbereich Sicherheit und Strahlenschutz

    2016-07-01

    In interpreting of measurement data for incorporation monitoring by excretion samples a clear distinction between the natural intake and the fraction subjected due to occupational exposure should be performed. At the present only a few data about an excretion of primordial elements such as {sup 238}U, {sup 232}Th are available in the literature. In the following study actual data measured in urine and faeces will be presented and discussed.

  19. Thio-dimethylarsinate is a common metabolite in urine samples from arsenic-exposed women in Bangladesh

    International Nuclear Information System (INIS)

    Raml, Reingard; Rumpler, Alice; Goessler, Walter; Vahter, Marie; Li Li; Ochi, Takafumi; Francesconi, Kevin A.

    2007-01-01

    Over the last 6 years, much work on arsenic species in urine samples has been directed toward the determination of the reduced dimethylated arsenic species, DMA(III), because of its high toxicity and perceived key role in the metabolism of inorganic arsenic. Recent work, however, has suggested that DMA(III) may at times have been misidentified because its chromatographic properties can be similar to those of thio-dimethylarsinate (thio-DMA). We analyzed by HPLC-ICPMS (inductively coupled plasma mass spectrometry) urine samples from 75 arsenic-exposed women from Bangladesh with total arsenic concentrations ranging from 8 to 1034 μg As/L and found that thio-DMA was present in 44% of the samples at concentrations ranging mostly from trace amounts to 24 μg As/L (one sample contained 123 μg As/L). Cytotoxicity testing with HepG2 cells derived from human hepatocarcinoma indicated that thio-DMA was about 10-fold more cytotoxic than dimethylarsinate (DMA). The widespread occurrence of thio-DMA in urine from these arsenic-exposed women suggests that this arsenical may also be present in other urine samples and has so far escaped detection. The work highlights the need for analytical methods providing specific determinations of arsenic compounds in future studies on arsenic metabolism and toxicology

  20. Thio-dimethylarsinate is a common metabolite in urine samples from arsenic-exposed women in Bangladesh

    Energy Technology Data Exchange (ETDEWEB)

    Raml, Reingard; Rumpler, Alice; Goessler, Walter [Karl-Franzens University Graz, Institute of Chemistry-Analytical Chemistry, Universitaetsplatz 1, 8010 Graz (Austria); Vahter, Marie; Li, Li [Institute of Environmental Medicine, Karolinska Institutet, PO Box 210, 17177 Stockholm (Sweden); Ochi, Takafumi [Laboratory of Toxicology, Faculty of Pharmaceutical Sciences, Teikyo University, Sagamiko, Kanagawa 199-0195 (Japan); Francesconi, Kevin A. [Karl-Franzens University Graz, Institute of Chemistry-Analytical Chemistry, Universitaetsplatz 1, 8010 Graz (Austria)], E-mail: kevin.francesconi@uni-graz.at

    2007-08-01

    Over the last 6 years, much work on arsenic species in urine samples has been directed toward the determination of the reduced dimethylated arsenic species, DMA(III), because of its high toxicity and perceived key role in the metabolism of inorganic arsenic. Recent work, however, has suggested that DMA(III) may at times have been misidentified because its chromatographic properties can be similar to those of thio-dimethylarsinate (thio-DMA). We analyzed by HPLC-ICPMS (inductively coupled plasma mass spectrometry) urine samples from 75 arsenic-exposed women from Bangladesh with total arsenic concentrations ranging from 8 to 1034 {mu}g As/L and found that thio-DMA was present in 44% of the samples at concentrations ranging mostly from trace amounts to 24 {mu}g As/L (one sample contained 123 {mu}g As/L). Cytotoxicity testing with HepG2 cells derived from human hepatocarcinoma indicated that thio-DMA was about 10-fold more cytotoxic than dimethylarsinate (DMA). The widespread occurrence of thio-DMA in urine from these arsenic-exposed women suggests that this arsenical may also be present in other urine samples and has so far escaped detection. The work highlights the need for analytical methods providing specific determinations of arsenic compounds in future studies on arsenic metabolism and toxicology.

  1. Measurement and application of purine derivatives: Creatinine ratio in spot urine samples of ruminants

    International Nuclear Information System (INIS)

    Chen, X.B.; Jayasuriya, M.C.N.; Makkar, H.P.S.

    2004-01-01

    The daily excretion of purine derivatives in urine has been used to estimate the supply of microbial protein to ruminant animals. The method provides a simple and non-invasive tool to indicate the nutritional status of farm animals. However due to the need for complete collection of urine the potential application at farm level is restricted. Research conducted under the FAO/IAEA Co-ordinated Research Project has indicated that it is possible to use the purine derivatives:creatinine ratio measured in several spot urine samples collected within a day, as an index of microbial protein supply in a banding system for farm application. Some theoretical and experimental aspects in the measurement of purine derivatives:creatinine ratio in spot urine samples and the possible application of the banding system at the farm level are discussed. (author)

  2. Phthalate metabolites in urine samples from Danish children and correlations with phthalates in dust samples from their homes and daycare centers

    DEFF Research Database (Denmark)

    Langer, S.; Bekö, Gabriel; Weschler, Charles J.

    2013-01-01

    Around the world humans use products that contain phthalates, and human exposure to certain of these phthalates has been associated with various adverse health effects. The aim of the present study has been to determine the concentrations of the metabolites of diethyl phthalate (DEP), di......(n-butyl) phthalate (DnBP), di(iso-butyl) phthalate (DiBP), butyl benzyl phthalate (BBzP) and di(2-ethylhexyl) phthalate (DEHP) in urine samples from 441 Danish children (3–6 years old). These children were subjects in the Danish Indoor Environment and Children's Health study. As part of each child's medical...... examination, a sample from his or her first morning urination was collected. These samples were subsequently analyzed for metabolites of the targeted phthalates. The measured concentrations of each metabolite were approximately log-normally distributed, and the metabolite concentrations significantly...

  3. A follow-up urine sample has limited value after treatment for urinary tract infection in children

    DEFF Research Database (Denmark)

    Lytzen, Rebekka; Kaalund-Jørgensen, Kristine; Ahmed, Akhlaq

    2015-01-01

    INTRODUCTION: A routine follow-up urine sample (FUS) in the form of a midstream urine sample (MSU) is recommended after treatment for urinary tract infection (UTI) according to the Danish Paediatric Society (DPS) and "Lægehåndbogen" published by Danish Regions. We studied the effect of FUS...

  4. Analysis of Drugs of Abuse in Anonymously Collected Urine and Soil samples from a Music Festival in Scandinavia

    DEFF Research Database (Denmark)

    Mardal, Marie; Ramin, Pedram; Plósz, Benedek G.

    Aim: Pooled human urine and soil from urinating spots were collected anonymously at a Scandinavian music festival. Samples should be screened for drugs of abuse, particularly novel psychoactive substances (NPS), but also therapeutic drugs and ethanol. Methods: Twenty-one urine samples were...... be detected besides several therapeutic drugs: cocaine (9), MDMA (7), sildenafil (2), ketamine (1), amphetamine (1), and oxycodone (1). Conclusions: NPS were detected neither in urine nor in soil samples. This might be due to low concentrations based on their negligible consumption at the studied festival...

  5. The Determination of Polyethylene Glycol in Untreated Urine Samples by High Performance Liquid Chromatography for Intestinal Permeability Studies

    DEFF Research Database (Denmark)

    Larsen, Elfinn; Pedersen, Walther Batsberg; Philipsen, E.

    1985-01-01

    Polyethylene glycol in urine samples has been investigated by high performance liquid chromatography. The molecular weights ranged from 634 to 1338. The urine samples were applied to the chromatographic system without any pre-treatment. For samples with a concentration of 0.2% polyethylene glycol...

  6. Comparison of the Abbott RealTime High Risk HPV test and the Roche cobas 4800 HPV test using urine samples.

    Science.gov (United States)

    Lim, Myong Cheol; Lee, Do-Hoon; Hwang, Sang-Hyun; Hwang, Na Rae; Lee, Bomyee; Shin, Hye Young; Jun, Jae Kwan; Yoo, Chong Woo; Lee, Dong Ock; Seo, Sang-Soo; Park, Sang-Yoon; Joo, Jungnam

    2017-05-01

    Human papillomavirus (HPV) testing based on cervical samples is important for use in cervical cancer screening. However, cervical sampling is invasive. Therefore, non-invasive methods for detecting HPV, such as urine samples, are needed. For HPV detection in urine samples, two real-time PCR (RQ-PCR) tests, Roche cobas 4800 test (Roche_HPV; Roche Molecular Diagnostics) and Abbott RealTime High Risk HPV test (Abbott_HPV; Abbott Laboratories) were compared to standard cervical samples. The performance of Roche_HPV and Abbott_HPV for HPV detection was evaluated at the National Cancer Center using 100 paired cervical and urine samples. The tests were also compared using urine samples stored at various temperatures and for a range of durations. The overall agreement between the Roche_HPV and Abbott_HPV tests using urine samples for any hrHPV type was substantial (86.0% with a kappa value of 0.7173), and that for HPV 16/18 was nearly perfect (99.0% with a kappa value of 0.9668). The relative sensitivities (based on cervical samples) for HPV 16/18 detection using Roche_HPV and Abbott_HPV with urine samples were 79.2% (95% CI; 57.9-92.9%) and 81.8% (95% CI; 59.7-94.8%), respectively. When the cut-off C T value for Abbott_HPV was extended to 40 for urine samples, the relative sensitivity of Abbott_HPV increased to 91.7% from 81.8% for HPV16/18 detection and to 87.0% from 68.5% for other hrHPV detection. The specificity was not affected by the change in the C T threshold. Roche_HPV and Abbott_HPV showed high concordance. However, HPV DNA detection using urine samples was inferior to HPV DNA detection using cervical samples. Interestingly, when the cut-off C T value was set to 40, Abbott_HPV using urine samples showed high sensitivity and specificity, comparable to those obtained using cervical samples. Fully automated DNA extraction and detection systems, such as Roche_HPV and Abbott_HPV, could reduce the variability in HPV detection and accelerate the standardization of HPV

  7. Rapid determination of {sup 90}Sr in urine samples using AnaLig Sr-01

    Energy Technology Data Exchange (ETDEWEB)

    Bilohuscin, J.; Dulanska, S.; Gardonova, V. [Univerzita Komenskeho, Prirodovedecka fakulta, Katedra jadrovej chemie, 84215 Bratislava (Slovakia)

    2013-04-16

    This work describes the use of IBC's AnaLig Sr-01 molecular recognition technology product to effectively and selectively pre-concentrate, separate and recover strontium from urine samples. This method uses two-stage columns separation consisting of two different commercial products Eichrom's Pre-filter Material and AnaLig Sr-01 column from IBC Advanced Technologies. This method does not involve co-precipitation of strontium as phosphates and oxalates from urine samples. The new rapid method separates strontium-90 with high chemical recovery (authors)

  8. Stability of drugs of abuse in urine samples stored at -20 degrees C.

    Science.gov (United States)

    Dugan, S; Bogema, S; Schwartz, R W; Lappas, N T

    1994-01-01

    Isolated studies of the stability of individual drugs of abuse have been reported. However, few have evaluated stability in frozen urine samples stored for 12 months. We have determined the stability of 11-nor-9-carboxy-delta 9-tetrahydrocannabinol (9-COOH-THC), amphetamine, methamphetamine, morphine, codeine, cocaine, benzoylecgonine, and phencyclidine in 236 physiological urine samples. Following the initial quantitative analysis, the samples were stored at -20 degrees C for 12 months and then reanalyzed. All drug concentrations were determined by gas chromatographic-mass spectrometric methods with cutoff concentrations of 5 ng/mL for 9-COOH-THC and phencyclidine and 100 ng/mL for each of the other drugs. The average change in the concentrations of these drugs following this long-term storage was not extensive except for an average change of -37% in cocaine concentrations.

  9. Misclassification of iodine intake level from morning spot urine samples with high iodine excretion among Inuit and non-Inuit in Greenland.

    Science.gov (United States)

    Andersen, Stig; Waagepetersen, Rasmus; Laurberg, Peter

    2015-05-14

    Iodine nutrition is commonly assessed from iodine excretion in urine. A 24 h urine sample is ideal, but it is cumbersome and inconvenient. Hence, spot urine samples with creatinine to adjust for differences in void volume are widely used. Still, the importance of ethnicity and the timing of spot urine samples need to be settled. We, thus, collected 104 early morning spot urine samples and 24 h urine samples from Inuit and non-Inuit living in Greenland. Diet was assessed by a FFQ. Demographic data were collected from the national registry and by questionnaires. Iodine was measured using the Sandell-Kolthoff reaction, creatinine using the Jaffe method and para-amino benzoic acid by the HPLC method for the estimation of completeness of urine sampling and compensation of incomplete urine samples to 24 h excretion. A population-based recruitment was done from the capital city, a major town and a settlement (n 36/48/20). Participants were seventy-eight Inuit and twenty-six non-Inuit. The median 24 h iodine excretion was 138 (25th-75th percentile 89-225) μg/97 (25th-75th percentile 72-124) μg in Inuit/non-Inuit (P= 0.030), and 153 (25th-75th percentile 97-251) μg/102 (25th-75th percentile 73-138) μg (P= 0.026) when including compensated iodine excretion. Iodine excretion in 24 h urine samples increased with a rising intake of traditional Inuit foods (P= 0.005). Iodine excretion was lower in morning spot urine samples than in 24 h urine samples (P< 0.001). This difference was associated with iodine intake levels (P< 0.001), and was statistically significant when the iodine excretion level was above 150 μg/24 h. In conclusion, the iodine intake level was underestimated from morning spot urine samples if iodine excretion was above the recommended level.

  10. Selenium speciation in human urine samples by LC- and CE-ICP-MS-separation and identification of selenosugars

    DEFF Research Database (Denmark)

    Gammelgaard, Bente; Bendahl, L.

    2004-01-01

    at ambient temperature and methanol extraction. A pre-concentration factor of 10 was achieved with this procedure. On occasions when a pre-concentration factor of 100 was obtained by lyophilsation and methanol extraction, at least 10 selenium compounds were separated in the urine sample. Urine samples were...

  11. Analysis of urine samples from metastatic bone cancer patients administered 153Sm-EDTMP

    International Nuclear Information System (INIS)

    Goeckeler, W.F.; Stoneburner, L.K.; Price, D.R.; Fordyce, W.A.

    1993-01-01

    153 Sm-EDTMP is currently undergoing clinical evaluation as a radiotherapeutic agent for the relief of pain associated with cancer metastatic to bone. These clinical studies have demonstrated biodistributions similar to those seen earlier in animals, namely, rapid clearance from blood, selective uptake in bone and in particular metastatic bone lesions. The radioactivity not deposited in bone is cleared through the kidneys into the urine. In this study, urine samples collected from 9 patients injected with 153 Sm-EDTMP underwent complexation analysis via Pharmacia SP-Sephadex C25 cation exchange chromatography. The results showed 96.9 ± 1.7% of the radioactivity in the urine to be present as a complex of 153 Sm. An HPLC method was developed and it was demonstrated that different complexes of 153 Sm could be separated. A non-radioactive analytical standard of the Sm-EDTMP chelate was synthesized, characterized and shown to have the same HPLC retention profile as the 153 -EDTMP drug product. HPLC analysis was performed on six urine samples and in each case a single radioactivity peak with an elution profile the same as that of a 153 Sm-EDTMP standard was observed. These results indicate that the 153 Sm-EDTMP chelate is excreted intact in the urine of patients. (Author)

  12. Use of a holder-vacuum tube device to save on-site hands in preparing urine samples for head-space gas-chromatography, and its application to determine the time allowance for sample sealing.

    Science.gov (United States)

    Kawai, Toshio; Sumino, Kimiaki; Ohashi, Fumiko; Ikeda, Masayuki

    2011-01-01

    To facilitate urine sample preparation prior to head-space gas-chromatographic (HS-GC) analysis. Urine samples containing one of the five solvents (acetone, methanol, methyl ethyl ketone, methyl isobutyl ketone and toluene) at the levels of biological exposure limits were aspirated into a vacuum tube via holder, a device commercially available for venous blood collection (the vacuum tube method). The urine sample, 5 ml, was quantitatively transferred to a 20-ml head-space vial prior to HS-GC analysis. The loaded tubes were stored at +4 ℃ in dark for up to 3 d. The vacuum tube method facilitated on-site procedures of urine sample preparation for HS-GC with no significant loss of solvents in the sample and no need of skilled hands, whereas on-site sample preparation time was significantly reduced. Furthermore, no loss of solvents was detected during the 3-d storage, irrespective of hydrophilic (acetone) or lipophilic solvent (toluene). In a pilot application, high performance of the vacuum tube method in sealing a sample in an air-tight space succeeded to confirm that no solvent will be lost when sealing is completed within 5 min after urine voiding, and that the allowance time is as long as 30 min in case of toluene in urine. The use of the holder-vacuum tube device not only saves hands for transfer of the sample to air-tight space, but facilitates sample storage prior to HS-GC analysis.

  13. Optimization of a Pre-MEKC Separation SPE Procedure for Steroid Molecules in Human Urine Samples

    Directory of Open Access Journals (Sweden)

    Ilona Olędzka

    2013-11-01

    Full Text Available Many steroid hormones can be considered as potential biomarkers and their determination in body fluids can create opportunities for the rapid diagnosis of many diseases and disorders of the human body. Most existing methods for the determination of steroids are usually time- and labor-consuming and quite costly. Therefore, the aim of analytical laboratories is to develop a new, relatively low-cost and rapid implementation methodology for their determination in biological samples. Due to the fact that there is little literature data on concentrations of steroid hormones in urine samples, we have made attempts at the electrophoretic determination of these compounds. For this purpose, an extraction procedure for the optimized separation and simultaneous determination of seven steroid hormones in urine samples has been investigated. The isolation of analytes from biological samples was performed by liquid-liquid extraction (LLE with dichloromethane and compared to solid phase extraction (SPE with C18 and hydrophilic-lipophilic balance (HLB columns. To separate all the analytes a micellar electrokinetic capillary chromatography (MECK technique was employed. For full separation of all the analytes a running buffer (pH 9.2, composed of 10 mM sodium tetraborate decahydrate (borax, 50 mM sodium dodecyl sulfate (SDS, and 10% methanol was selected. The methodology developed in this work for the determination of steroid hormones meets all the requirements of analytical methods. The applicability of the method has been confirmed for the analysis of urine samples collected from volunteers—both men and women (students, amateur bodybuilders, using and not applying steroid doping. The data obtained during this work can be successfully used for further research on the determination of steroid hormones in urine samples.

  14. Influence of Freezing and Storage Procedure on Human Urine Samples in NMR-Based Metabolomics

    Directory of Open Access Journals (Sweden)

    Burkhard Luy

    2013-04-01

    Full Text Available It is consensus in the metabolomics community that standardized protocols should be followed for sample handling, storage and analysis, as it is of utmost importance to maintain constant measurement conditions to identify subtle biological differences. The aim of this work, therefore, was to systematically investigate the influence of freezing procedures and storage temperatures and their effect on NMR spectra as a potentially disturbing aspect for NMR-based metabolomics studies. Urine samples were collected from two healthy volunteers, centrifuged and divided into aliquots. Urine aliquots were frozen either at −20 °C, on dry ice, at −80 °C or in liquid nitrogen and then stored at −20 °C, −80 °C or in liquid nitrogen vapor phase for 1–5 weeks before NMR analysis. Results show spectral changes depending on the freezing procedure, with samples frozen on dry ice showing the largest deviations. The effect was found to be based on pH differences, which were caused by variations in CO2 concentrations introduced by the freezing procedure. Thus, we recommend that urine samples should be frozen at −20 °C and transferred to lower storage temperatures within one week and that freezing procedures should be part of the publication protocol.

  15. Influence of Freezing and Storage Procedure on Human Urine Samples in NMR-Based Metabolomics.

    Science.gov (United States)

    Rist, Manuela J; Muhle-Goll, Claudia; Görling, Benjamin; Bub, Achim; Heissler, Stefan; Watzl, Bernhard; Luy, Burkhard

    2013-04-09

    It is consensus in the metabolomics community that standardized protocols should be followed for sample handling, storage and analysis, as it is of utmost importance to maintain constant measurement conditions to identify subtle biological differences. The aim of this work, therefore, was to systematically investigate the influence of freezing procedures and storage temperatures and their effect on NMR spectra as a potentially disturbing aspect for NMR-based metabolomics studies. Urine samples were collected from two healthy volunteers, centrifuged and divided into aliquots. Urine aliquots were frozen either at -20 °C, on dry ice, at -80 °C or in liquid nitrogen and then stored at -20 °C, -80 °C or in liquid nitrogen vapor phase for 1-5 weeks before NMR analysis. Results show spectral changes depending on the freezing procedure, with samples frozen on dry ice showing the largest deviations. The effect was found to be based on pH differences, which were caused by variations in CO2 concentrations introduced by the freezing procedure. Thus, we recommend that urine samples should be frozen at -20 °C and transferred to lower storage temperatures within one week and that freezing procedures should be part of the publication protocol.

  16. Validity of a portable urine refractometer: the effects of sample freezing.

    Science.gov (United States)

    Sparks, S Andy; Close, Graeme L

    2013-01-01

    The use of portable urine osmometers is widespread, but no studies have assessed the validity of this measurement technique. Furthermore, it is unclear what effect freezing has on osmolality. One-hundred participants of mean (±SD) age 25.1 ± 7.6 years, height 1.77 ± 0.1 m and weight 77.1 ± 10.8 kg provided single urine samples that were analysed using freeze point depression (FPD) and refractometry (RI). Samples were then frozen at -80°C (n = 81) and thawed prior to re-analysis. Differences between methods and freezing were determined using Wilcoxon's signed rank test. Relationships between measurements were assessed using intraclass correlation coefficients (ICC) and typical error of estimate (TE). Osmolality was lower (P = 0.001) using RI (634.2 ± 339.8 mOsm · kgH2O(-1)) compared with FPD (656.7 ± 334.1 mOsm · kgH2O(-1)) but the TE was trivial (0.17). Freezing significantly reduced mean osmolality using FPD (656.7 ± 341.1 to 606.5 ± 333.4 mOsm · kgH2O(-1); P < 0.001), but samples were still highly related following freezing (ICC, r = 0.979, P < 0.001, CI = 0.993-0.997; TE = 0.15; and r=0.995, P < 0.001, CI = 0.967-0.986; TE = 0.07 for RI and FPD respectively). Despite mean differences between methods and as a result of freezing, such differences are physiologically trivial. Therefore, the use of RI appears to be a valid measurement tool to determine urine osmolality.

  17. The influence of freezer storage of urine samples on the BONN-Risk-Index for calcium oxalate crystallization.

    Science.gov (United States)

    Laube, Norbert; Zimmermann, Diana J

    2004-01-01

    This study was performed to quantify the effect of a 1-week freezer storage of urine on its calcium oxalate crystallization risk. Calcium oxalate is the most common urinary stone material observed in urolithiasis patients in western and affluent countries. The BONN-Risk-Index of calcium oxalate crystallization risk in human urine is determined from a crystallization experiment performed on untreated native urine samples. We tested the influence of a 1-week freezing on the BONN-Risk-Index value as well as the effect of the sample freezing on the urinary osmolality. In vitro crystallization experiments in 49 native urine samples from stone-forming and non-stone forming individuals were performed in order to determine their calcium oxalate crystallization risk according to the BONN-Risk-Index approach. Comparison of the results derived from original sample investigations with those obtained from the thawed aliquots by statistical evaluation shows that i) no significant deviation from linearity between both results exists and ii) both results are identical by statistical means. This is valid for both, the BONN-Risk-Index and the osmolality data. The differences in the BONN-Risk-Index results of both procedures of BONN-Risk-Index determination, however, exceed the clinically acceptable difference. Thus, determination of the urinary calcium oxalate crystallization risk from thawed urine samples cannot be recommended.

  18. Ultra-trace determination of neptunium-237 and plutonium isotopes in urine samples by compact accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dai, X.; Christl, M.; Kramer-Tremblay, S., E-mail: sheila.kramer-tremblay@cnl.ca [Canadian Nuclear Laboratories, Chalk River, Ontario (Canada); Synal, H-A. [ETH Zurich, Lab. of Ion Beam Physics, Zurich (Switzerland)

    2015-12-15

    Ultra-trace analysis of actinides, such as Pu isotopes and {sup 237}Np, in bioassay samples is often needed for radiation protection programs at nuclear facilities. Accelerator mass spectrometry (AMS), particularly the compact ETH Zurich system “Tandy”, has evolved over the years as one of the most sensitive, selective, and robust techniques for actinide analysis. Employment of the AMS technique can reduce the demands on sample preparation chemistry and increase sample analysis throughput, due to very low instrumental detection limit, high rejection of interferences, and low susceptibility to adverse sample matrices. Initial research and development tests were performed to explore and demonstrate the analytical capability of AMS for Pu and Np urine bioassay. In this study, urine samples spiked with femtogram levels of Np and Pu isotopes were prepared and measured using compact ETH AMS system and the results showed excellent analytical capability for measuring Np and Pu isotopes at femtogram/litre levels in urine. (author)

  19. Direct Agglutination Test and Enzyme Linked Immunosorbent Assay with Urine Samples for the Diagnosis of Visceral Leishma-niasis

    Directory of Open Access Journals (Sweden)

    Sarkari B

    2007-07-01

    Full Text Available Background: Visceral leishmaniasis (VL or Kala azar is an infectious disease caused by various species of Leishmania parasites. The aim of this study was to detect and compare the presence of anti-Leishmania antibodies in the urine of vis-ceral leishmaniasis patients using ELISA and DAT methods."nMethods: A total of 30 urine samples were collected from VL patients referred to Shiraz (southeast of Iran hospitals. Moreover 31 urine samples were collected from healthy individuals and patients with other diseases such as malaria, brucellosis, hydatidosis and cutaneous leishmaniasis. Collected samples were examined to detect anti-Leishmania antibod-ies in urine, using ELISA and DAT."nResults: Anti-Leishmania antibody was detected in urine of 18 out of 30 (60% VL patients by DAT while ELISA detected anti-Leishmania antibodies in urine of 28 out of 30 (93.3% of VL cases. Sensitivity and specificity of urine-based DAT was 60% and 83.9%, respectively while sensitivity and specificity of urine-based ELISA were 93.3% and 93.5%, corre-spondingly. "nConclusion: Urine-based DAT and ELISA have a reasonable specificity and sensitivity in diagnosis of VL. Accordingly, urine-based ELISA might be a suitable alternative for serum based assays for diagnosis of VL.

  20. Evaluation of a nested-PCR for mycobacterium tuberculosis detection in blood and urine samples.

    Science.gov (United States)

    da Cruz, Heidi Lacerda Alves; de Albuquerque Montenegro, Rosana; de Araújo Lima, Juliana Falcão; da Rocha Poroca, Diogo; da Costa Lima, Juliana Figueirêdo; Maria Lapa Montenegro, Lílian; Crovella, Sergio; Charifker Schindler, Haiana

    2011-01-01

    The polymerase chain reaction (PCR) and its variations, such as the nested-PCR, have been described as promising techniques for rapid diagnosis of tuberculosis (TB). With the aim of evaluating the usefulness of a nested-PCR method on samples of blood and urine of patients suspected of tuberculosis we analyzed 192 clinical samples, using as a molecular target the insertion element IS6110 specific of M. tuberculosis genome. Nested-PCR method showed higher sensitivity in patients with extrapulmonary tuberculosis (47.8% and 52% in blood and urine) when compared to patients with the pulmonary form of the disease (sensitivity of 29% and 26.9% in blood and urine), regardless of the type of biological sample used. The nested-PCR is a rapid technique that, even if not showing a good sensitivity, should be considered as a helpful tool especially in the extrapulmonary cases or in cases where confirmatory diagnosis is quite difficult to be achieved by routine methods. The performance of PCR-based techniques should be considered and tested in future works on other types of biological specimens besides sputum, like blood and urine, readily obtainable in most cases. The improving of M. tuberculosis nested-PCR detection in TB affected patients will give the possibility of an earlier detection of bacilli thus interrupting the transmission chain of the disease.

  1. Determinations of tritium levels in urine and blood samples, medical checkups of persons employed at RC Seibersdorf

    International Nuclear Information System (INIS)

    Irlweck, K.; Teherani, D.K.

    1975-07-01

    Tritium determinations in urine and blood samples were performed with a liquid scintillation counter (Tri Carb No. 3375, PACKARD). In urine samples tritiated water (HTO) was measured after separation of organic substances by adsorption with activated charcoal and following distillation to dryness. In some urine and blood samples total Tritium content was determinated by conbustion in a sample Oxidizer (Mod. 306, PACKARD). Detection limits for HTO and total Tritium measurements were 2,5 pCi/ml and 7 or 15 pCi/ml respectively, taking 2 sigma of statistical error of background values. Tritiumconcentrations in daily urine of occupational exposed persons, employed in RC Seibersdorf occurred up to 8 pCi HTO/ml. An arithmetic mean was 3,85+-2,11 pCi/ml from investigations on 16 persons. Tritiumcontent in urine samples of occupational non exposed persons were about the same level up to 10 pCi HTO/ml. An arithmetic mean was 3,70+-2,65 pCi/ml from measurements on 20 persons. Statistical error of single values was sigma=+-1,85 pCi/ml. There was found no significantly higher concentration in urine of occupational exposed persons compared with a group of non exposed ones. Total Tritium content in urine samples seemed to be somewhat higher than HTO concentrations, also for occupational non exposed persons. Tritium levels in blood were notably higher than have to be expected assuming homogeneous distribution of HTO in body fluids. For occupational exposed persons in RC Seibersdorf Tritium concentrations between 26-58 pCi/ml were found. An estimation about Tritium intake based on such results showed no more than 0,5% of maximum permissible intake for occupational exposed persons in the most unfavorable case. For occupational non exposed persons total Tritium levels in blood were only about 10,7+-5,8 pCi/ml (arithmetic mean of measurements on 15 persons). (author)

  2. Statistical analysis of fluoride levels in human urine and drinking water samples of fluorinated area of punjab (pakistan)

    International Nuclear Information System (INIS)

    Qayyum, M.; Zaman, W.U.; Rehman, R.; Ahmad, B.; Ahmad, M.; Ali, S.; Murtaza, S

    2013-01-01

    Increasing fluoride levels in drinking water of fluorinated areas of world leading to fluorosis. For bio-monitoring of fluorosis patients, fluoride levels were determined in drinking water and human urine samples of different individuals having dental fluorosis and bony deformities from fluorotic area of Punjab (Sham Ki Bhatiyan, Pakistan) and then compared with reference samples of non fluorotic area (Queens Road, Lahore, Pakistan) using ion selective electrode methodology. Fluoride levels in fluorinated area differ significantly from control group (p < 0.05). In drinking water and human urine samples, fluoride levels in fluorinated areas were: 136.192 +- 67.836 and 94.484 +- 36.572 micro molL/sup -1/ respectively, whereas in control samples, fluoride concentrations were: 19.306 +- 2.109 and 47.154 +- 22.685 micro molL/sup -1/ in water and urine samples correspondingly. Pearson's correlation data pointed out the fact that that human urine and water fluoride concentrations have a significant positive dose response relationship with the prevalence of dental and skeletal fluorosis in fluorotic areas having higher fluoride levels in drinking water. (author)

  3. Stability of Drugs of Abuse in Urine Samples at Room Temperature by Use of a Salts Mixture.

    Science.gov (United States)

    Pellegrini, Manuela; Graziano, Silvia; Mastrobattista, Luisa; Minutillo, Adele; Busardo, Francesco Paolo; Scarsella, Gianfranco

    2017-01-01

    It has long been recognized that ensuring analyte stability is of crucial importance in the use of any quantitative bioanalytical method. As analyses are usually not performed directly after collection of the biological samples, but after these have been processed and stored, it is essential that analyte stability can be maintained at storage conditions to ensure that the obtained concentration results adequately reflect those directly after sampling. The conservation of urine samples in refrigerated/ frozen conditions is strongly recommended; but not always feasible. The aim of this study was to assess the stability of some well-known drugs of abuse methamphetamine (MA), 11-nor-9-carboxy-Δ9- tetrahydrocannabinol (THC-COOH), benzoylecgonine (BE), and morphine (MOR) in urine samples kept at room temperature by adding a salt mixture (sodium citrate, sodium ascorbate, borax). Two different urine samples were prepared with and without salt mixture, stored at room temperature and then analyzed by gas chromatography-mass spectrometry at 0, 1, 7, 15, and 30 days after collection/preparation to look for eventual analyte degradation. Methamphetamine showed no significant changes with respect to the time of collection/ preparation (T0) up to 7 days later (T7), with or without salt mixture addiction. Then a significant degradation occurred in both salted and non salted urine. BE decrease was observed starting from day 1 after sample collection in salted and not salted samples, respectively. Salt addition seemed to reduce at least the initial BE degradation, with a significant difference (pstorage. However, the degradation was not more prevented in salted samples at 30 days of storage. A 20% decrease of MOR concentration was observed starting from day 1 after collection/preparation, both in salted and not salted samples with no subsequent decrease. With regard to THCCOOH, a significant decrease was observed starting from 7 days after collection/preparation, with of without

  4. SELDI-TOF MS of quadruplicate urine and serum samples to evaluate changes related to storage conditions.

    Science.gov (United States)

    Traum, Avram Z; Wells, Meghan P; Aivado, Manuel; Libermann, Towia A; Ramoni, Marco F; Schachter, Asher D

    2006-03-01

    Proteomic profiling with SELDI-TOF MS has facilitated the discovery of disease-specific protein profiles. However, multicenter studies are often hindered by the logistics required for prompt deep-freezing of samples in liquid nitrogen or dry ice within the clinic setting prior to shipping. We report high concordance between MS profiles within sets of quadruplicate split urine and serum samples deep-frozen at 0, 2, 6, and 24 h after sample collection. Gage R&R results confirm that deep-freezing times are not a statistically significant source of SELDI-TOF MS variability for either blood or urine.

  5. Direct determination of lead in human urine and serum samples by electrothermal atomic absorption spectrometry and permanent modifiers

    International Nuclear Information System (INIS)

    Andrada, Daniel; Pinto, Frederico G.; Magalhaes, Cristina Goncalves; Nunes, Berta R.; Silva, Jose Bento Borba da; Franco, Milton B.

    2006-01-01

    The object of the present study was the development of alternative methods for the direct determination of lead in undigested samples of human urine and serum by electrothermal atomic absorption spectrometry (ETAAS). Thus, some substances have been investigated to act as chemical modifiers. Volumes of 20 μL of diluted samples, 1 + 1, v/v for urine and 1 + 4, v/v for serum, with HNO 3 1% v/v and 0.02% v/v of cetyl trimethyl ammonium chloride (CTAC) were prepared directly in the autosampler cups and placed into the graphite furnace. For modifiers in solutions 10 μL were used. Pyrolysis and atomization temperature curves were used in all optimizations in the matrixes diluted as exposed. For urine with permanent iridium (500 μg), the best pyrolysis and atomization temperatures were 900 and 1600 deg C, respectively, with a characteristic mass of 12 pg (recommended of 10 pg), with symmetrical absorption pulses and corrected background. Spiked urine samples presented recoveries between 86 and 112% for Ir permanent. The analysis results of certified urine samples are in agreement with certified values (95% of confidence) for two levels of the metal. For serum, good results were obtained with the mixture of Zr+Rh or Ir+Rh as permanent modifiers, with characteristic masses of 9.8 and 8.1 pg, respectively. Recoveries from spiked serum samples varied between 98.6 and 100.1% (Ir+Rh) and between 93.9 and 105.2% (Zr+Rh). In both recovery studies, the relative standard deviation (n=3) was lower than 7%. Calibration for both samples were made with aqueous calibration curves and presented r 2 higher than 0.99. The limits of detection were 0.7 μg L -1 for serum samples, with Zr+Rh permanent, and 1.0 μg L -1 for urine with iridium permanent. (author)

  6. Direct determination of lead in human urine and serum samples by electrothermal atomic absorption spectrometry and permanent modifiers

    Directory of Open Access Journals (Sweden)

    Andrada Daniel

    2006-01-01

    Full Text Available The object of the present study was the development of alternative methods for the direct determination of lead in undigested samples of human urine and serum by electrothermal atomic absorption spectrometry (ET AAS. Thus, some substances have been investigated to act as chemical modifiers. Volumes of 20 µL of diluted samples, 1 + 1, v/v for urine and 1 + 4, v/v for serum, with HNO3 1% v/v and 0.02% v/v of cetil trimethyl ammonium chloride (CTAC were prepared directly in the autosampler cups and placed into the graphite furnace. For modifiers in solutions 10 µL were used. Pyrolysis and atomization temperature curves were used in all optimizations in the matrixes diluted as exposed. For urine with permanent iridium (500 µg, the best pyrolysis and atomization temperatures were 900 and 1600 ºC, respectively, with a characteristic mass of 12 pg (recommended of 10 pg, with symmetrical absorption pulses and corrected background. Spiked urine samples presented recoveries between 86 and 112% for Ir permanent. The analysis results of certified urine samples are in agreement with certified values (95% of confidence for two levels of the metal. For serum, good results were obtained with the mixture of Zr+Rh or Ir+Rh as permanent modifiers, with characteristic masses of 9.8 and 8.1 pg, respectively. Recoveries from spiked serum samples varied between 98.6 and 100.1% (Ir+Rh and between 93.9 and 105.2% (Zr+Rh. In both recovery studies, the relative standard deviation (n=3 was lower than 7%. Calibration for both samples were made with aqueous calibration curves and presented r² higher than 0.99. The limits of detection were 0.7 µg L-1 for serum samples, with Zr+Rh permanent, and 1.0 µg L-1 for urine with iridium permanent.

  7. Determination of cadmium and lead in urine samples after dispersive solid–liquid extraction on multiwalled carbon nanotubes by slurry sampling electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Álvarez Méndez, J.; Barciela García, J.; García Martín, S.; Peña Crecente, R.M.; Herrero Latorre, C., E-mail: carlos.herrero@usc.es

    2015-04-01

    A new method for the determination of Cd and Pb in urine samples has been developed. The method involves dispersive solid-phase extraction (DSPE), slurry sampling (SS), and subsequent electrothermal atomic absorption spectrometry (ETAAS). Oxidized multiwalled carbon nanotubes (MWCNTs) were used as the sorbent material. The isolated MWCNT/analyte aggregates were treated with nitric acid to form a slurry and both metals were determined directly by injecting the slurry into the ETAAS-atomizer. The parameters that influence the adsorption of the metals on MWCNTs in the DSPE process, the formation and extraction of the slurry, and the ETAAS conditions were studied by different factorial design strategies. The detection and quantification limits obtained for Cd under optimized conditions were 9.7 and 32.3 ng L{sup −1}, respectively, and for Pb these limits were 0.13 and 0.43 μg L{sup −1}. The preconcentration factors achieved were 3.9 and 5.4. The RSD values (n = 10) were less than 4.1% and 5.9% for Cd and Pb, respectively. The accuracy of the method was assessed in recovery studies, with values in the range 96–102% obtained for Cd and 97–101% for Pb. In addition, the analysis of certified reference materials gave consistent results. The DSPE–SS–ETAAS method is a novel and useful strategy for the determination of Pb and Cd at low levels in human urine samples. The method is sensitive, fast, and free of matrix interferences, and it avoids the tedious and time-consuming on-column adsorption and elution steps associated with commonly used SPE procedures. The proposed method was used to determine Cd and Pb in urine samples of unexposed healthy people and satisfactory results were obtained. - Highlights: • Cd and Pb determination based on the combination of DSP, SS and ETAAS • Urine matrix was eliminated using DSPE based on multiwalled carbon nanotubes. • Slurry sampling technique permitted the direct injection of sample into the ETAAS atomizer.

  8. Metabonomics-Based Study of Clinical Urine Samples in Suboptimal Health with Different Syndromes

    Directory of Open Access Journals (Sweden)

    Hai-Zhen Cui

    2013-01-01

    Full Text Available Objective. To explore the urinary biochemistry features of syndromes of traditional Chinese medicine (TCM such as syndrome of stagnation of liver Qi, spleen deficiency, liver Qi stagnation, and spleen deficiency (LSSDS in sub-optimal health status (SHS. Methods. 12 cases for each syndrome group in SHS were selected, 12 subjects were used as a normal control group, and 1H NMR detection was, respectively, carried out, and the data was corrected by the orthogonal signal correction (OSC and then adopted a partial least squares (PLS method for discriminate analysis. Results. The OSC-PLS (ctr analysis results of the nuclear overhauser enhancement spectroscopy (NOESY detection indicated that the syndromes in SHS could be differentiated, and there were significant differences in the levels of metabolites of the urine samples of the four groups; the biomarkers of LSSDS in SHS were found out. The contents of citric acid (2.54 and 2.66, trimethylamineoxide (3.26, and hippuric acid (3.98, 7.54, 7.58, 7.62, 7.66, 7.82, and 7.86 in the urine samples of LSSDS group were lower than that of the normal control group. Conclusion. There are differences in the 1H-NMR metabolic spectrum of the urine samples of the four groups, and the specific metabolic products of the LSSDS in SHS can be identified from metabonomics analysis.

  9. Analysis of Fluconazole in Human Urine Sample by High Performance Liquid Chromatography Method

    International Nuclear Information System (INIS)

    Hermawan, D; Ali, N A Md; Ibrahim, W A Wan; Sanagi, M M

    2013-01-01

    A method for determination of fluconazole, antifungal drug in human urine by using reversed-phased high performance liquid chromatography (RP-HPLC) with ultraviolet (UV) detector was developed. Optimization HPLC conditions were carried out by changing the flow rate and composition of mobile phase. The optimum separation conditions at a flow rate 0.85 mL/min with a composition of mobile phase containing methanol:water (70:30, v/v) with UV detection at a wavelength 254 nm was able to analyze fluconazole within 3 min. The excellent linearity was obtained in the range of concentration 1 to 10 μg/mL with r 2 = 0.998. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.39 μg/mL and 1.28 μg/mL, respectively. Solid phase extraction (SPE) method using octadecylsilane (C18) as a sorbent was used to clean-up and pre-concentrated of the urine sample prior to HPLC analysis. The average recoveries of fluconazole in spiked urine sample was 72.4% with RSD of 3.21% (n=3).

  10. Detection of Salmonella typhi by nested polymerase chain reaction in blood, urine, and stool samples

    NARCIS (Netherlands)

    Hatta, Mochammad; Smits, Henk L.

    2007-01-01

    A nested polymerase chain reaction (PCR) specific for Salmonella enterica serovar Typhi was used for the detection of the pathogen in blood, urine, and stool samples from 131 patients with clinical suspicion of typhoid fever. The sensitivity of blood culture, the PCRs with blood, urine, and feces,

  11. Human urine as test material in 1H NMR-based metabonomics: recommendations for sample preparation and storage.

    Science.gov (United States)

    Lauridsen, Michael; Hansen, Steen H; Jaroszewski, Jerzy W; Cornett, Claus

    2007-02-01

    Metabonomic approaches are believed to have the capability of revolutionizing diagnosis of diseases and assessment of patient conditions after medical interventions. In order to ensure comparability of metabonomic 1H NMR data from different studies, we suggest validated sample preparation guidelines for human urine based on a stability study that evaluates effects of storage time and temperature, freeze-drying, and the presence of preservatives. The results indicated that human urine samples should be stored at or below -25 degrees C, as no changes in the 1H NMR fingerprints have been observed during storage at this temperature for 26 weeks. Formation of acetate, presumably due to microbial contamination, was occasionally observed in samples stored at 4 degrees C without addition of a preservative. Addition of a preserving agent is not mandatory provided that the samples are stored at -25 degrees C. Thus, no differences were observed between 1H NMR spectra of nonpreserved urines and urines with added sodium azide and stored at -25 degrees C, whereas the presence of sodium fluoride caused a shift of especially citrate resonances. Freeze-drying of urine and reconstitution in D2O at pH 7.4 resulted in the disappearance of the creatinine CH2 signal at delta 4.06 due to deuteration. A study evaluating the effects of phosphate buffer concentration on signal variability and assessment of the probability of citrate or creatinine resonances crossing bucket border (a boundary between adjacent integrated regions) led to the conclusion that a minimum buffer concentration of 0.3 M is adequate for normal urines used in this study. However, final buffer concentration of 1 M will be required for very concentrated urines.

  12. Quality assurance in the pre-analytical phase of human urine samples by (1)H NMR spectroscopy.

    Science.gov (United States)

    Budde, Kathrin; Gök, Ömer-Necmi; Pietzner, Maik; Meisinger, Christine; Leitzmann, Michael; Nauck, Matthias; Köttgen, Anna; Friedrich, Nele

    2016-01-01

    Metabolomic approaches investigate changes in metabolite profiles, which may reflect changes in metabolic pathways and provide information correlated with a specific biological process or pathophysiology. High-resolution (1)H NMR spectroscopy is used to identify metabolites in biofluids and tissue samples qualitatively and quantitatively. This pre-analytical study evaluated the effects of storage time and temperature on (1)H NMR spectra from human urine in two settings. Firstly, to evaluate short time effects probably due to acute delay in sample handling and secondly, the effect of prolonged storage up to one month to find markers of sample miss-handling. A number of statistical procedures were used to assess the differences between samples stored under different conditions, including Projection to Latent Structure Discriminant Analysis (PLS-DA), non-parametric testing as well as mixed effect linear regression analysis. The results indicate that human urine samples can be stored at 10 °C for 24 h or at -80 °C for 1 month, as no relevant changes in (1)H NMR fingerprints were observed during these time periods and temperature conditions. However, some metabolites most likely of microbial origin showed alterations during prolonged storage but without facilitating classification. In conclusion, the presented protocol for urine sample handling and semi-automatic metabolite quantification is suitable for large-scale epidemiological studies. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. [Delayed testing for the diagnosis of fungi in the urines. Evaluation of the BD Vacutainer C&S tubes for the storage of urine samples at room temperature].

    Science.gov (United States)

    Baixench, M T; Al-Sheikh, M; Paugam, A

    2005-01-01

    The study included 37 urine samples which have been artificially infected with low levels (10(3) CFU/mL) of various fungi strains. We compared the effects of sample storage, up to 48 hours, at room temperature, in a urine evacuated tube containing specific additives with storage at + 4 degrees C, for the same length of time, in a urine evacuated tube without any additives. There have been no differences of results (speed of growth and colony size) between the 2 modes of storage. However, the experience has shown that samples needed a careful mixing before seeding to avoid underdetection of the strains. Based on the study results, the BD Vacutainer C&S tubes are suitable for delayed testing for the diagnosis of urine fungal infection.

  14. Agreement of pesticide biomarkers between morning void and 24-h urine samples from farmers and their children.

    Science.gov (United States)

    Scher, Deanna P; Alexander, Bruce H; Adgate, John L; Eberly, Lynn E; Mandel, Jack S; Acquavella, John F; Bartels, Michael J; Brzak, Kathy A

    2007-07-01

    In pesticide biomonitoring studies, researchers typically collect either single voids or daily (24-h) urine samples. Collection of 24-h urine samples is considered the "gold-standard", but this method places a high burden on study volunteers, requires greater resources, and may result in misclassification of exposure or underestimation of dose due to noncompliance with urine collection protocols. To evaluate the potential measurement error introduced by single void samples, we present an analysis of exposure and dose for two commonly used pesticides based on single morning void (MV) and 24-h urine collections in farmers and farm children. The agreement between the MV concentration and its corresponding 24-h concentration was analyzed using simple graphical and statistical techniques and risk assessment methodology. A consistent bias towards overprediction of pesticide concentration was found among the MVs, likely in large part due to the pharmacokinetic time course of the analytes in urine. These results suggest that the use of single voids can either over- or under-estimate daily exposure if recent pesticide applications have occurred. This held true for both farmers as well as farm children, who were not directly exposed to the applications. As a result, single void samples influenced the number of children exposed to chlorpyrifos whose daily dose estimates were above levels of toxicologic significance. In populations where fluctuations in pesticide exposure are expected (e.g., farm families), the pharmacokinetics of the pesticide and the timing of exposure events and urine collection must be understood when relying on single voids as a surrogate for longer time-frames of exposure.

  15. Direct Analysis of Amphetamine Stimulants in a Whole Urine Sample by Atmospheric Solids Analysis Probe Tandem Mass Spectrometry

    Science.gov (United States)

    Crevelin, Eduardo J.; Salami, Fernanda H.; Alves, Marcela N. R.; De Martinis, Bruno S.; Crotti, Antônio E. M.; Moraes, Luiz A. B.

    2016-05-01

    Amphetamine-type stimulants (ATS) are among illicit stimulant drugs that are most often used worldwide. A major challenge is to develop a fast and efficient methodology involving minimal sample preparation to analyze ATS in biological fluids. In this study, a urine pool solution containing amphetamine, methamphetamine, ephedrine, sibutramine, and fenfluramine at concentrations ranging from 0.5 pg/mL to 100 ng/mL was prepared and analyzed by atmospheric solids analysis probe tandem mass spectrometry (ASAP-MS/MS) and multiple reaction monitoring (MRM). A urine sample and saliva collected from a volunteer contributor (V1) were also analyzed. The limit of detection of the tested compounds ranged between 0.002 and 0.4 ng/mL in urine samples; the signal-to-noise ratio was 5. These results demonstrated that the ASAP-MS/MS methodology is applicable for the fast detection of ATS in urine samples with great sensitivity and specificity, without the need for cleanup, preconcentration, or chromatographic separation. Thus ASAP-MS/MS could potentially be used in clinical and forensic toxicology applications.

  16. Direct trace-elemental analysis of urine samples by laser ablation-inductively coupled plasma mass spectrometry after sample deposition on clinical filter papers.

    Science.gov (United States)

    Aramendía, Maite; Rello, Luis; Vanhaecke, Frank; Resano, Martín

    2012-10-16

    Collection of biological fluids on clinical filter papers shows important advantages from a logistic point of view, although analysis of these specimens is far from straightforward. Concerning urine analysis, and particularly when direct trace elemental analysis by laser ablation-inductively coupled plasma mass spectrometry (LA-ICPMS) is aimed at, several problems arise, such as lack of sensitivity or different distribution of the analytes on the filter paper, rendering obtaining reliable quantitative results quite difficult. In this paper, a novel approach for urine collection is proposed, which circumvents many of these problems. This methodology consists on the use of precut filter paper discs where large amounts of sample can be retained upon a single deposition. This provides higher amounts of the target analytes and, thus, sufficient sensitivity, and allows addition of an adequate internal standard at the clinical lab prior to analysis, therefore making it suitable for a strategy based on unsupervised sample collection and ulterior analysis at referral centers. On the basis of this sampling methodology, an analytical method was developed for the direct determination of several elements in urine (Be, Bi, Cd, Co, Cu, Ni, Sb, Sn, Tl, Pb, and V) at the low μg L(-1) level by means of LA-ICPMS. The method developed provides good results in terms of accuracy and LODs (≤1 μg L(-1) for most of the analytes tested), with a precision in the range of 15%, fit-for-purpose for clinical control analysis.

  17. Measurement of 239Pu in urine samples at ultra-trace levels using a 1 MV compact AMS system

    International Nuclear Information System (INIS)

    Hernandez-Mendoza, H.; Chamizo, E.; Yllera, A.; Garcia-Leon, M.; Delgado, A.

    2010-01-01

    Routine bioassay monitoring of Pu intake in exposed workers of research and nuclear industry is usually performed by alpha spectrometry. This technique involves large sample volumes of urine and time-consuming preparative and counting protocols. Compact accelerator mass spectrometry (AMS) facilities make feasible the determination of ultra low-level Pu activity concentrations and Pu isotopic ratios in biological samples (blood, urine and feces), being a rapid and cost-effective measurement technique. The plutonium results in urine samples presented here have been obtained on the 1 MV compact AMS system sited at the Centro Nacional de Aceleradores (CNA), in Seville, Spain. In this work, a different methodological approach has been developed alternative to the 'classical' preparation of urine samples for alpha spectrometry. The procedure avoids the Pu precipitation step, and involves acid sample evaporation and acid digestion in a microwave oven. Finally, purification of plutonium was achieved by using chromatography columns filled up with BioRad AG1X2 anion exchange resin (Bio-Rad Laboratories Inc.). The total time needed for analysis is about 10 h, unlike the 'classical' methods based on alpha spectrometry which need about 1 week. At present, it has been demonstrated that this method allows quantifying 239 Pu activity concentrations in urine of, at least, 30 μBq (13 fg 239 Pu). We can conclude that the procedure would be suitable to perform in vitro routine bioassay measurements. Moreover, the innovative application of AMS opens new and interesting analytical alternatives in this field.

  18. Comparison of uncertainties related to standardization of urine samples with volume and creatinine concentration

    DEFF Research Database (Denmark)

    Garde, Anne Helene; Hansen, Ase Marie; Kristiansen, Jesper

    2004-01-01

    When measuring biomarkers in urine, volume (and time) or concentration of creatinine are both accepted methods of standardization for diuresis. Both types of standardization contribute uncertainty to the final result. The aim of the present paper was to compare the uncertainty introduced when usi...... increase in convenience for the participants, when collecting small volumes rather than complete 24 h samples....... the two types of standardization on 24 h samples from healthy individuals. Estimates of uncertainties were based on results from the literature supplemented with data from our own studies. Only the difference in uncertainty related to the two standardization methods was evaluated. It was found...... that the uncertainty associated with creatinine standardization (19-35%) was higher than the uncertainty related to volume standardization (up to 10%, when not correcting for deviations from 24 h) for 24 h urine samples. However, volume standardization introduced an average bias of 4% due to missed volumes...

  19. Effects of storage time and temperature on pH, specific gravity, and crystal formation in urine samples from dogs and cats.

    Science.gov (United States)

    Albasan, Hasan; Lulich, Jody P; Osborne, Carl A; Lekcharoensuk, Chalermpol; Ulrich, Lisa K; Carpenter, Kathleen A

    2003-01-15

    To determine effects of storage temperature and time on pH and specific gravity of and number and size of crystals in urine samples from dogs and cats. Randomized complete block design. 31 dogs and 8 cats. Aliquots of each urine sample were analyzed within 60 minutes of collection or after storage at room or refrigeration temperatures (20 vs 6 degrees C [68 vs 43 degrees F]) for 6 or 24 hours. Crystals formed in samples from 11 of 39 (28%) animals. Calcium oxalate (CaOx) crystals formed in vitro in samples from 1 cat and 8 dogs. Magnesium ammonium phosphate (MAP) crystals formed in vitro in samples from 2 dogs. Compared with aliquots stored at room temperature, refrigeration increased the number and size of crystals that formed in vitro; however, the increase in number and size of MAP crystals in stored urine samples was not significant. Increased storage time and decreased storage temperature were associated with a significant increase in number of CaOx crystals formed. Greater numbers of crystals formed in urine aliquots stored for 24 hours than in aliquots stored for 6 hours. Storage time and temperature did not have a significant effect on pH or specific gravity. Urine samples should be analyzed within 60 minutes of collection to minimize temperature- and time-dependent effects on in vitro crystal formation. Presence of crystals observed in stored samples should be validated by reevaluation of fresh urine.

  20. Post mortem concentrations of endogenous gamma hydroxybutyric acid (GHB) and in vitro formation in stored blood and urine samples.

    Science.gov (United States)

    Busardò, Francesco Paolo; Bertol, Elisabetta; Vaiano, Fabio; Baglio, Giovanni; Montana, Angelo; Barbera, Nunziata; Zaami, Simona; Romano, Guido

    2014-10-01

    Gamma-hydroxybutyrate (GHB) is a central nervous system depressant, primarily used as a recreational drug of abuse with numerous names. It has also been involved in various instances of drug-facilitated sexual assault due to its potential incapacitating effects. The first aim of this paper is to measure the post-mortem concentration of endogenous GHB in whole blood and urine samples of 30 GHB free-users, who have been divided according to the post-mortem interval (PMI) in three groups (first group: 24-36h; second group: 37-72h; third group: 73-192h), trying to evaluate the role of PMI in affecting post mortem levels. Second, the Authors have evaluated the new formation of GHB in vitro in blood and urine samples of the three groups, which have been stored at -20°C, 4°C and 20°C over a period of one month. The concentrations were measured by GC-MS after liquid-liquid extraction according to the method validated and published by Elliot (For. Sci. Int., 2003). For urine samples, GHB concentrations were creatinine-normalized. In the first group the GHB mean concentration measured after autopsy was: 2.14mg/L (range 0.54-3.21mg/L) in blood and 3.90mg/g (range 0.60-4.81mg/g) in urine; in the second group it was: 5.13mg/L (range 1.11-9.60mg/L) in blood and 3.93mg/g (range 0.91-7.25mg/g) in urine; in the third group it was: 11.8mg/L (range 3.95-24.12mg/L) in blood and 9.83mg/g (range 3.67-21.90mg/g) in urine. The results obtained in blood and urine samples showed a statistically significant difference among groups (pblood and urine samples a mean difference at 20°C compared to -20°C not statistically significant at the 10% level. These findings allow us to affirm that the PMI strongly affects the post mortem production of GHB in blood and urine samples. Regarding the new formation of GHB in vitro both in blood and urine samples of the three groups, which have been stored at -20°C, 4°C and 20°C over a period of one month, although there was no significant increases of

  1. Controversies in using urine samples for prostate cancer detection: PSA and PCA3 expression analysis

    Directory of Open Access Journals (Sweden)

    S. Fontenete

    2011-12-01

    Full Text Available PURPOSE: Prostate cancer (PCa is one of the most commonly diagnosed malignancies in the world. Although PSA utilization as a serum marker has improved prostate cancer detection it still presents some limitations, mainly regarding its specificity. The expression of this marker, along with the detection of PCA3 mRNA in urine samples, has been suggested as a new approach for PCa detection. The goal of this work was to evaluate the efficacy of the urinary detection of PCA3 mRNA and PSA mRNA without performing the somewhat embarrassing prostate massage. It was also intended to optimize and implement a methodological protocol for this kind of sampling. MATERIALS AND METHODS: Urine samples from 57 patients with suspected prostate disease were collected, without undergoing prostate massage. Increased serum PSA levels were confirmed by medical records review. RNA was extracted by different methods and a preamplification step was included in order to improve gene detection by Real-Time PCR. RESULTS: An increase in RNA concentration with the use of TriPure Isolation Reagent. Despite this optimization, only 15.8% of the cases showed expression of PSA mRNA and only 3.8% of prostate cancer patients presented detectable levels of PCA3 mRNA. The use of a preamplification step revealed no improvement in the results obtained. CONCLUSION: This work confirms that prostate massage is important before urine collection for gene expression analysis. Since PSA and PCA3 are prostate specific, it is necessary to promote the passage of cells from prostate to urinary tract, in order to detect these genetic markers in urine samples.

  2. Nappy pad urine samples for investigation and treatment of UTI in young children: the 'DUTY' prospective diagnostic cohort study.

    Science.gov (United States)

    Butler, Christopher C; Sterne, Jonathan Ac; Lawton, Michael; O'Brien, Kathryn; Wootton, Mandy; Hood, Kerenza; Hollingworth, William; Little, Paul; Delaney, Brendan C; van der Voort, Judith; Dudley, Jan; Birnie, Kate; Pickles, Timothy; Waldron, Cherry-Ann; Downing, Harriet; Thomas-Jones, Emma; Lisles, Catherine; Rumsby, Kate; Durbaba, Stevo; Whiting, Penny; Harman, Kim; Howe, Robin; MacGowan, Alasdair; Fletcher, Margaret; Hay, Alastair D

    2016-07-01

    The added diagnostic utility of nappy pad urine samples and the proportion that are contaminated is unknown. To develop a clinical prediction rule for the diagnosis of urinary tract infection (UTI) based on sampling using the nappy pad method. Acutely unwell children UTI; diagnostic utility quantified as area under the receiver operator curves (AUROC). Nappy pad rule characteristics, AUROC, and contamination, compared with findings from clean-catch samples. Nappy pad samples were obtained from 3205 children (82% aged UTI on culture. Female sex, smelly urine, darker urine, and the absence of nappy rash were independently associated with a UTI, with an internally-validated, coefficient model AUROC of 0.81 (0.87 for clean-catch), which increased to 0.87 (0.90 for clean-catch) with the addition of dipstick results. GPs' 'working diagnosis' had an AUROC 0.63 (95% confidence intervals [CI] = 0.53 to 0.72). A total of 12.2% of nappy pad and 1.8% of clean-catch samples were 'frankly contaminated' (risk ratio 6.66; 95% CI = 4.95 to 8.96; P<0.001). Nappy pad urine culture results, with features that can be reported by parents and dipstick tests, can be clinically useful, but are less accurate and more often contaminated compared with clean-catch urine culture. © British Journal of General Practice 2016.

  3. MicroRNA profiling of dogs with transitional cell carcinoma of the bladder using blood and urine samples.

    Science.gov (United States)

    Kent, Michael S; Zwingenberger, Allison; Westropp, Jodi L; Barrett, Laura E; Durbin-Johnson, Blythe P; Ghosh, Paramita; Vinall, Ruth L

    2017-11-15

    Early signs of canine transitional cell carcinoma (TCC) are frequently assumed to be caused by other lower urinary tract diseases (LUTD) such as urinary tract infections, resulting in late diagnosis of TCC which could be fatal. The development of a non-invasive clinical test for TCC could dramatically reduce mortality. To determine whether microRNAs (miRNAs) can be used as non-invasive diagnostic biomarkers, we assessed miRNA expression in blood and/or urine from dogs with clinically normal bladders (n = 28), LUTD (n = 25), and TCC (n = 17). Expression levels of 5 miRNA associated with TCC pathophysiology (miR-34a, let-7c, miR-16, miR-103b, and miR-106b) were assessed by quantitative real-time PCR. Statistical analyses using ranked ANOVA identified significant differences in miR-103b and miR-16 levels between urine samples from LUTD and TCC patients (miR-103b, p = 0.002; and miR-16, p = 0.016). No statistically significant differences in miRNA levels were observed between blood samples from LUTD versus TCC patients. Expression levels of miR-34a trended with miR-16, let-7c, and miR-103b levels in individual normal urine samples, however, this coordination was completely lost in TCC urine samples. In contrast, co-ordination of miR-34a, miR-16, let-7c, and miR-103b expression levels was maintained in blood samples from TCC patients. Our combined data indicate a potential role for miR-103b and miR-16 as diagnostic urine biomarkers for TCC, and that further investigation of miR-103b and miR-16 in the dysregulation of coordinated miRNA expression in bladder carcinogenesis is warranted.

  4. Analysis of chlorpheniramine in human urine samples using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Mehdi Maham

    2014-09-01

    Full Text Available A simple and environmentally friendly microextraction technique was used for determination of chlorpheniramine (CPM, an antihistamine drug, in human urine samples using dispersive liquid-liquid microextraction (DLLME followed by high performance liquid chromatography with diode array detection (HPLC-DAD. In this extraction technique, an appropriate mixture of acetonitrile (disperser solvent and carbon tetrachloride (extraction solvent was rapidly injected into the urine sample containing the target analyte. Tiny droplets of extractant were formed and dispersed into the sample solution and then sedimented at the bottom of the conical test tube by centrifugation. Under optimal conditions, the calibration curve was linear in the range of 0.055-5.5 µg mL-1, with a detection limit of 16.5 ng mL-1. This proposed method was successfully applied to the analysis of real urine samples. Low consumption of toxic organic solvents, simplicity of operation, low cost and acceptable figures of merit are the main advantages of the proposed technique.

  5. Influence of Freezing and Storage Procedure on Human Urine Samples in NMR-Based Metabolomics

    OpenAIRE

    Rist, Manuela; Muhle-Goll, Claudia; Görling, Benjamin; Bub, Achim; Heissler, Stefan; Watzl, Bernhard; Luy, Burkhard

    2013-01-01

    It is consensus in the metabolomics community that standardized protocols should be followed for sample handling, storage and analysis, as it is of utmost importance to maintain constant measurement conditions to identify subtle biological differences. The aim of this work, therefore, was to systematically investigate the influence of freezing procedures and storage temperatures and their effect on NMR spectra as a potentially disturbing aspect for NMR-based metabolomics studies. Urine sample...

  6. [Sampling, storage and transport of biological materials collected from living and deceased subjects for determination of concentration levels of ethyl alcohol and similarly acting substances. A proposal of updating the blood and urine sampling protocol].

    Science.gov (United States)

    Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew

    2007-01-01

    The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.

  7. Correlation of the levels of glycosaminoglycans between urine and dried urine in filter paper samples and their stability over time under different storage temperatures.

    Science.gov (United States)

    Breier, Ana Carolina; Cé, Jaqueline; Coelho, Janice Carneiro

    2014-06-10

    Mucopolysaccharidoses (MPSs) are a group of lysosomal storage diseases caused by the deficiency/absence of enzymes which catalyze the degradation of glycosaminoglycans (GAGs). The use of biological samples dried on filter paper has been increasing because it makes it easy to ship them to reference laboratories. Urinary GAGs are the main biomarkers of MPS and, thus, we studied the correlations of determinations to GAGs and creatinine, as well as compared the GAGs' profile on electrophoresis, between urine and dried urine in filter paper (DUFP) samples. We also assessed the GAG stability over time under different storage temperatures. We quantified the GAG concentration in both sample types and compared the results by Pearson correlation. The results were very similar, with r=0.97 for creatinine and with r=0.94 and r=0.98 for GAGs for controls and patients, respectively, with similar electrophoretic profiles. The GAG stability in DUFP was up to 30days at -20, 4, and 25°C and up to 21days at 37°C. Our proposal assessed urinary GAGs in DUFP and concluded that these samples can be used in the investigation of MPS, replacing urine samples in neonatal screening and monitoring of therapies, due to ease of transportation and storage. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Detection of tobacco-related biomarkers in urine samples by surface-enhanced Raman spectroscopy coupled with thin-layer chromatography.

    Science.gov (United States)

    Huang, Rongfu; Han, Sungyub; Li, Xiao Sheryl

    2013-08-01

    The nicotine metabolites, cotinine and trans-3'-hydroxycotinine (3HC) are considered as superior biomarkers for identifying tobacco exposure. More importantly, the ratio of 3HC to cotinine is a good indicator to phenotype individuals for cytochrome P450 2A6 activity and to individualize pharmacotherapy for tobacco addiction. In this paper, a simple, robust and novel method based on surface-enhanced Raman spectroscopy coupled with thin-layer chromatography (TLC) was developed to directly quantify the biomarkers in human urine samples. This is the first time surface-enhanced Raman spectroscopy (SERS) was used to detect cotinine and 3HC in urine samples. The linear dynamic range for the detection of cotinine is from 40 nM to 8 μM while that of 3HC is from 1 μM to 15 μM. The detection limits are 10 nM and 0.2 μM for cotinine and 3HC, respectively. The proposed method was further validated by quantifying the concentration of both cotinine and 3HC in smokers' urine samples. This TLC-SERS method allows the direct detection of cotinine in the urine samples of both active and passive smokers and the detection of 3HC in smokers.

  9. Discordant genotyping results using DNA isolated from anti-doping control urine samples.

    Science.gov (United States)

    Choong, Eva; Schulze, Jenny J; Ericsson, Magnus; Rane, Anders; Ekström, Lena

    2017-07-01

    The UGT2B17 gene deletion polymorphism is known to correlate to urinary concentration of testosterone-glucuronide and hence this genotype exerts a large impact on the testosterone/epitestosterone (T/E) ratio, a biomarker for testosterone doping. The objective of this study was to assess if DNA isolated from athletes' urine samples (n = 713) obtained in routine doping controls could be targeted for genotyping analysis for future integration in the athlete's passport. A control population (n = 21) including both urine and blood DNA was used for genotyping concordance test. Another aim was to study a large group (n = 596) of authentic elite athletes in respect of urinary steroid profile in relation to genetic variation. First we found that the genotype results when using urine-derived DNA did not correlate sufficiently with the genotype obtained from whole blood DNA. Secondly we found males with one or two UGT2B17 alleles had higher T/E (mean 1.63 ± 0.93) than females (mean 1.28 ± 1.08), p˂0.001. Unexpectedly, we found that several male del/del athletes in power sports had a T/E ˃1. If men in power sport exert a different urinary steroid profile needs to be further investigated. The other polymorphisms investigated in the CYP17A1, UGT2B7 and UGT2B15 genes did not show any associations with testosterone and epitestosterone concentrations. Our results show that genotyping using urine samples according to our method is not useful in an anti-doping setting. Instead, it is of importance for the anti-doping test programs to include baseline values in the ABP to minimize any putative impact of genotype. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  10. Prevalence of urinary tract infection in acutely unwell children in general practice: a prospective study with systematic urine sampling.

    Science.gov (United States)

    O'Brien, Kathryn; Edwards, Adrian; Hood, Kerenza; Butler, Christopher C

    2013-02-01

    Urinary tract infection (UTI) in children may be associated with long-term complications that could be prevented by prompt treatment. To determine the prevalence of UTI in acutely ill children ≤ 5 years presenting in general practice and to explore patterns of presenting symptoms and urine sampling strategies. Prospective observational study with systematic urine sampling, in general practices in Wales, UK. In total, 1003 children were recruited from 13 general practices between March 2008 and July 2010. The prevalence of UTI was determined and multivariable analysis performed to determine the probability of UTI. Out of 597 (60.0%) children who provided urine samples within 2 days, the prevalence of UTI was 5.9% (95% confidence interval [CI] = 4.3% to 8.0%) overall, 7.3% in those UTI (P = 0.64; P = 0.69, respectively). The probability of UTI in children aged ≥3 years without increased urinary frequency or dysuria was 2%. The probability of UTI was ≥5% in all other groups. Urine sampling based purely on GP suspicion would have missed 80% of UTIs, while a sampling strategy based on current guidelines would have missed 50%. Approximately 6% of acutely unwell children presenting to UK general practice met the criteria for a laboratory diagnosis of UTI. This higher than previously recognised prior probability of UTI warrants raised awareness of the condition and suggests clinicians should lower their threshold for urine sampling in young children. The absence of fever or presence of an alternative source of infection, as emphasised in current guidelines, may not rule out UTI in young children with adequate certainty.

  11. The identification of type 1 Gaucher disease patients, asymptomatic cases and carriers in The Netherlands using urine samples: an evaluation

    NARCIS (Netherlands)

    Aerts, J. M.; Sa Miranda, M. C.; Wanzeller de Lacerda, L.; van Weely, S.; Donker-Koopman, W.; Brouwer-Kelder, B.; Jansen, D. C.; van Leeuwen, M.; Schram, A. W.; Tsiapara, A.

    1991-01-01

    The feasibility of using urine samples for the identification of patients with Gaucher disease and carriers has been investigated. It was found that the pH of a urine sample should be pH 6.0 or lower to ensure stability of lysosomal hydrolases. Two parameters of glucocerebrosidase, which is

  12. Antibiogram of escherichia coli isolated from urine samples at a tertiary care hospital

    International Nuclear Information System (INIS)

    Chaudary, Z.A.; Hasan, A.; Alizai, S.A.

    2015-01-01

    To determine prevalence and antibiotic susceptibility pattern of the E. coli isolated from urine in our setup, especially in low income group of population. Methodology: The study was carried out from July 2010 to June 2011 at surgical and urological units of a hospital in Islamabad. E.coli were isolated from urine specimens by following standard microbiological techniques. Antimicrobial susceptibility test was performed by using the Kirby-Bauer disc diffusion techniques according to CLSI guidelines. Results: The prevalence of E. coli isolated from urine samples was 28.22%. Highest resistance was seen against ampicillin (80.3%). Imipenem was found out to be highly effective. Conclusion: Imipenem, ciprofloxacin and sparfloxacin can be reliably used against E. coli causing urinary tract infections. Gentamicin and moxifloxacin also showed satisfactory results. (author)

  13. Determination of γ-hydroxybutyrate in human urine samples by ion exclusion and ion exchange two-dimensional chromatography system.

    Science.gov (United States)

    Liu, Junwei; Deng, Zhifen; Zhu, Zuoyi; Wang, Yong; Wang, Guoqing; Sun, Yu-An; Zhu, Yan

    2017-12-15

    A two-dimensional ion chromatography system was developed for the determination of γ-hydroxybutyrate (GHB) in human urine samples. Ion exclusion chromatography was used in the first dimensional separation for elimination of urine matrices and detection of GHB above 10mgL -1 , ion exchange chromatography was used in the second dimensional separation via column-switching technique for detection of GHB above 0.08mgL -1 . Under the optimized chromatographic conditions, the ion exclusion and ion exchange chromatography separation system exhibited satisfactory repeatability (RSDchromatography system was convenient and practical for the determination of GHB in human urine samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Nappy pad urine samples for investigation and treatment of UTI in young children: the ‘DUTY’ prospective diagnostic cohort study

    Science.gov (United States)

    Butler, Christopher C; Sterne, Jonathan AC; Lawton, Michael; O’Brien, Kathryn; Wootton, Mandy; Hood, Kerenza; Hollingworth, William; Little, Paul; Delaney, Brendan C; van der Voort, Judith; Dudley, Jan; Birnie, Kate; Pickles, Timothy; Waldron, Cherry-Ann; Downing, Harriet; Thomas-Jones, Emma; Lisles, Catherine; Rumsby, Kate; Durbaba, Stevo; Whiting, Penny; Harman, Kim; Howe, Robin; MacGowan, Alasdair; Fletcher, Margaret; Hay, Alastair D

    2016-01-01

    Background The added diagnostic utility of nappy pad urine samples and the proportion that are contaminated is unknown. Aim To develop a clinical prediction rule for the diagnosis of urinary tract infection (UTI) based on sampling using the nappy pad method. Design and setting Acutely unwell children UTI; diagnostic utility quantified as area under the receiver operator curves (AUROC). Nappy pad rule characteristics, AUROC, and contamination, compared with findings from clean-catch samples. Results Nappy pad samples were obtained from 3205 children (82% aged UTI on culture. Female sex, smelly urine, darker urine, and the absence of nappy rash were independently associated with a UTI, with an internally-validated, coefficient model AUROC of 0.81 (0.87 for clean-catch), which increased to 0.87 (0.90 for clean-catch) with the addition of dipstick results. GPs’ ‘working diagnosis’ had an AUROC 0.63 (95% confidence intervals [CI] = 0.53 to 0.72). A total of 12.2% of nappy pad and 1.8% of clean-catch samples were ‘frankly contaminated’ (risk ratio 6.66; 95% CI = 4.95 to 8.96; P<0.001). Conclusion Nappy pad urine culture results, with features that can be reported by parents and dipstick tests, can be clinically useful, but are less accurate and more often contaminated compared with clean-catch urine culture. PMID:27364678

  15. Genotyping of Leptospira directly in urine samples of cattle demonstrates a diversity of species and strains in Brazil.

    Science.gov (United States)

    Hamond, C; Pestana, C P; Medeiros, M A; Lilenbaum, W

    2016-01-01

    The aim of this study was to identify Leptospira in urine samples of cattle by direct sequencing of the secY gene. The validity of this approach was assessed using ten Leptospira strains obtained from cattle in Brazil and 77 DNA samples previously extracted from cattle urine, that were positive by PCR for the genus-specific lipL32 gene of Leptospira. Direct sequencing identified 24 (31·1%) interpretable secY sequences and these were identical to those obtained from direct DNA sequencing of the urine samples from which they were recovered. Phylogenetic analyses identified four species: L. interrogans, L. borgpetersenii, L. noguchii, and L. santarosai with the most prevalent genotypes being associated with L. borgpetersenii. While direct sequencing cannot, as yet, replace culturing of leptospires, it is a valid additional tool for epidemiological studies. An unexpected finding from this study was the genetic diversity of Leptospira infecting Brazilian cattle.

  16. Analytical sample preparation strategies for the determination of antimalarial drugs in human whole blood, plasma and urine

    DEFF Research Database (Denmark)

    Casas, Monica Escolà; Hansen, Martin; Krogh, Kristine A

    2014-01-01

    the available sample preparation strategies combined with liquid chromatographic (LC) analysis to determine antimalarials in whole blood, plasma and urine published over the last decade. Sample preparation can be done by protein precipitation, solid-phase extraction, liquid-liquid extraction or dilution. After...

  17. Estimation of salt intake from spot urine samples in patients with chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Ogura Makoto

    2012-06-01

    Full Text Available Abstract Background High salt intake in patients with chronic kidney disease (CKD may cause high blood pressure and increased albuminuria. Although, the estimation of salt intake is essential, there are no easy methods to estimate real salt intake. Methods Salt intake was assessed by determining urinary sodium excretion from the collected urine samples. Estimation of salt intake by spot urine was calculated by Tanaka’s formula. The correlation between estimated and measured sodium excretion was evaluated by Pearson´s correlation coefficients. Performance of equation was estimated by median bias, interquartile range (IQR, proportion of estimates within 30% deviation of measured sodium excretion (P30 and root mean square error (RMSE.The sensitivity and specificity of estimated against measured sodium excretion were separately assessed by receiver-operating characteristic (ROC curves. Results A total of 334 urine samples from 96 patients were examined. Mean age was 58 ± 16 years, and estimated glomerular filtration rate (eGFR was 53 ± 27 mL/min. Among these patients, 35 had CKD stage 1 or 2, 39 had stage 3, and 22 had stage 4 or 5. Estimated sodium excretion significantly correlated with measured sodium excretion (R = 0.52, P 170 mEq/day (AUC 0.835. Conclusions The present study demonstrated that spot urine can be used to estimate sodium excretion, especially in patients with low eGFR.

  18. Uranium isotopes determination in urine samples using alpha spectrometry and ICP-MS

    International Nuclear Information System (INIS)

    Rosa, Mychelle M.L.; Maihara, Vera A.; Tine, Fernanda D.; Santos, Sandra M.C.; Bonifacio, Rodrigo L.; Taddei, Maria HelenaT.

    2015-01-01

    The action of determining the concentration of uranium isotopes in biological samples, 'in vitro' bioassay, is an indirect method for evaluating the incorporation and quantification of these radionuclides internally deposited. When incorporated, these radionuclides tend to be disposed through excretion, with urine being the main source of data because it can be easily collected and analyzed. The most widely used methods for determination of uranium isotopes ( 234 U, 235 U and 238 U) are Alpha Spectrometry and ICP-MS. This work presents a comparative study for the determination of uranium isotopes using these two methodologies in real samples from occupationally exposed workers. In order to validate the methodology, a sample of the intercomparison exercise organized by PROCORAD (Association pour la Promotion du Controle de Qualite des Analyses de Biologie Medicale em Radiotoxicologie) was used, and the results were statistically compared applying the Student's t-test. (author)

  19. Sample preparation and UHPLC-FD analysis of pteridines in human urine.

    Science.gov (United States)

    Tomšíková, H; Solich, P; Nováková, L

    2014-07-01

    Elevated levels of pteridines can indicate the activation of cellular immune system by certain diseases. No work dealing with the simultaneous determination of urinary neopterin, biopterin and their reduced forms has been published. Therefore, a new SPE-UHPLC-FD method for the analysis of these compounds has been developed. The main emphasis was put on the stability of dihydroforms during the sample processing and storage. As a stabilizing agent, dithiothreitol, at various concentrations, and various pH values (3.8-9.8) of working solutions were tested. Chromatographic separation was performed under HILIC isocratic conditions on BEH Amide column. The method was linear for the calibration standard solutions in the range of 10-10,000 ng/ml (dihydroforms) and 0.5-1000 ng/ml (oxidized forms), and for real samples in the range of 25-1000 ng/ml (dihydroforms) and 1-100 ng/ml (oxidized forms). The development of a new SPE sample preparation method was carried out on different types of sorbents (based on a mixed-mode cation exchange, porous graphitic carbon and a polymer comprising hydrophilic and hydrophobic components). Final validation was performed on a MCAX SPE column. Method accuracy ranged from 76.9 to 121.9%. The intra- and inter-day precision did not exceed 10.7%. The method provided high sensitivity for the use in routine clinical measurements of urine (LLOQ 1 ng/ml for oxidized forms and 25 ng/ml for dihydroforms). Average concentrations of biopterin, neopterin, and dihydrobiopterin found in urine of healthy persons were related to the mol of creatinine (66.8, 142.3, and 257.3 μmol/mol of creatinine, respectively) which corresponded to the literature data. The concentration of dihydroneopterin obtained using our method was 98.8 μmol/mol of creatinine. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Using hair, nail and urine samples for human exposure assessment of legacy and emerging per- and polyfluoroalkyl substances.

    Science.gov (United States)

    Wang, Yuan; Shi, Yali; Vestergren, Robin; Zhou, Zhen; Liang, Yong; Cai, Yaqi

    2018-09-15

    Non-invasive samples present ethical and practical benefits for investigating human exposure to hazardous contaminants, but analytical challenges and difficulties to interpret the results limit their application in biomonitoring. Here we investigated the potential for using hair, nail and urine samples as a measure of internal exposure to an array of legacy and emerging per- and polyfluoroalkyl substances (PFASs) in two populations with different exposure conditions. Paired urine-serum measurements of PFASs from a group of highly exposed fishery employees displayed strong correlations for PFASs with three to eight perfluorinated carbons (ρ > 0.653; p < 0.01). Consistent statistical correlations and transfer ratios in nails and hair from both populations demonstrated that these non-invasive samples can be used as a measure of internal exposure to perfluorooctane sulfonic acid and C8 chlorinated polyfluoralkyl ether sulfonic acid (C8 Cl-PFESA). Contrastingly, the infrequent detections and/or lack of consistent transfer ratios for perfluorooctanoic acid, perfluorononanoic acid and short-chain PFASs in hair and nail samples indicate passive uptake from the external environment rather than uptake and internal distribution. Collectively, the study supports the use of urine samples as a valid measure of internal exposure for a range of short- and medium-chain PFASs, while the validity of nail and hair samples as a measure of internal exposure may vary for different PFASs and populations. The ubiquitous detection of C8 Cl-PFESA in all sample matrices from both populations indicates widespread exposure to this contaminant of emerging concern in China. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Detection of Wuchereria bancrofti DNA in paired serum and urine samples using polymerase chain reaction-based systems

    Directory of Open Access Journals (Sweden)

    Camila Ximenes

    2014-12-01

    Full Text Available The Global Program for the Elimination of Lymphatic Filariasis (GPELF aims to eliminate this disease by the year 2020. However, the development of more specific and sensitive tests is important for the success of the GPELF. The present study aimed to standardise polymerase chain reaction (PCR-based systems for the diagnosis of filariasis in serum and urine. Twenty paired biological urine and serum samples from individuals already known to be positive for Wuchereria bancrofti were collected during the day. Conventional PCR and semi-nested PCR assays were optimised. The detection limit of the technique for purified W. bancrofti DNA extracted from adult worms was 10 fg for the internal systems (WbF/Wb2 and 0.1 fg by using semi-nested PCR. The specificity of the primers was confirmed experimentally by amplification of 1 ng of purified genomic DNA from other species of parasites. Evaluation of the paired urine and serum samples by the semi-nested PCR technique indicated only two of the 20 tested individuals were positive, whereas the simple internal PCR system (WbF/Wb2, which has highly promising performance, revealed that all the patients were positive using both samples. This study successfully demonstrated the possibility of using the PCR technique on urine for the diagnosis of W. bancrofti infection.

  2. Verification of a simple method to achieve alpha/beta separation in LSC for the case of urine samples

    International Nuclear Information System (INIS)

    Oestergren, Inger; Norrlid, Lilian; Wallberg, Lena

    2008-01-01

    Full text: As a part of the national Swedish network of laboratories in emergency response and preparedness, the radio-analytical laboratory of the Swedish Radiation Protection Authority (SSI) should provide with fast and reliable measurements. To this purpose, Liquid Scintillation Counting (LSC) offers the advantages of reduced time for sample preparation, zero sample self-absorption, simultaneously measurement of alpha and beta emitters and high efficiency. The LSC detection system at SSI is a Quantulus 1220, which is a system permitting pulses produced by alpha and beta radiation to be discriminated when adjusting the software parameter Pulse Shape Analysis (PSA). Previously, different authors have found that the dependency of the optimum PSA on scintillation/vial combination is negligible in front of the strong influence of the sample quenching. Also the optimum PSA parameter is found according to each sample quench level, so as the composition of a standard and a real sample should be as close as possible. When handling samples of variable quenching levels, like for example urine, two possibilities have been suggested: 1) To determine the degree of quench in a short count of the samples and then use individual optimum PSA for each sample counting protocol; or 2) To have alpha and beta standards equivalent in quenching to the least quenched sample, determine PSA and quench the standards progressively. Then the percent of total interference is obtained as a function of the quench parameter for a single PSA setting, which permits the samples to be counted with the same protocol and a correction for interference can be applied afterwards. The case of urine is interesting since it is 95 % water but it may contain traces of amino acids and varying amounts of electrolytes, depending upon dietary intake. In this paper we applied number 2. The standards have been quenched to simulate human urine quench levels. The aim is to obtain the look-up table for the percent of

  3. Utility of Cytospin and Cell block Technology in Evaluation of Body Fluids and Urine Samples: A Comparative Study.

    Science.gov (United States)

    Qamar, Irmeen; Rehman, Suhailur; Mehdi, Ghazala; Maheshwari, Veena; Ansari, Hena A; Chauhan, Sunanda

    2018-01-01

    Cytologic examination of body fluids commonly involves the use of direct or sediment smears, cytocentrifuge preparations, membrane filter preparations, or cell block sections. Cytospin and cell block techniques are extremely useful in improving cell yield of thin serous effusions and urine samples, and ensure high diagnostic efficacy. We studied cytospin preparations and cell block sections prepared from 180 samples of body fluids and urine samples to compare the relative efficiency of cell retrieval, preservation of cell morphology, ease of application of special stains, and diagnostic efficacy. Samples were collected and processed to prepare cytospin smears and cell block sections. We observed that overall, cell yield and preservation of individual cell morphology were better in cytospin preparations as compared to cell blocks, while preservation of architectural pattern was better in cell block sections. The number of suspicious cases also decreased on cell block sections, with increased detection of malignancy. It was difficult to prepare cell blocks from urine samples due to low cellularity. Cytospin technology is a quick, efficient, and cost-effective method of increasing cell yield in hypocellular samples, with better preservation of cell morphology. Cell blocks are better prepared from high cellularity fluids; however, tissue architecture is better studied, with improved rate of diagnosis and decrease in ambiguous results. Numerous sections can be prepared from a small amount of material. Special stains and immunochemical stains can be easily applied to cell blocks. It also provides a source of archival material.

  4. Molecularly imprinted solid-phase extraction of glutathione from urine samples

    International Nuclear Information System (INIS)

    Song, Renyuan; Hu, Xiaoling; Guan, Ping; Li, Ji; Zhao, Na; Wang, Qiaoli

    2014-01-01

    Molecularly imprinted polymer (MIP) particles for glutathione were synthesized through iniferter-controlled living radical precipitation polymerization (IRPP) under ultraviolet radiation at ambient temperature. Static adsorption, solid-phase extraction, and high-performance liquid chromatography were carried out to evaluate the adsorption properties and selective recognition characteristics of the polymers for glutathione and its structural analogs. The obtained IRPP-MIP particles exhibited a regularly spherical shape, rapid binding kinetics, high imprinting factor, and high selectivity compared with the MIP particles prepared using traditional free-radical precipitation polymerization. The selective separation and enrichment of glutathione from the mixture of glycyl-glycine and glutathione disulfide could be achieved on the IRPP-MIP cartridge. The recoveries of glutathione, glycyl-glycine, and glutathione disulfide were 95.6% ± 3.65%, 29.5% ± 1.26%, and 49.9% ± 1.71%, respectively. The detection limit (S/N = 3) of glutathione was 0.5 mg·L −1 . The relative standard deviations (RSDs) for 10 replicate detections of 50 mg·L −1 of glutathione were 5.76%, and the linear range of the calibration curve was 0.5 mg·L −1 to 200 mg·L −1 under optimized conditions. The proposed approach was successfully applied to determine glutathione in spiked human urine samples with recoveries of 90.24% to 96.20% and RSDs of 0.48% to 5.67%. - Highlights: • Imprinted polymer particles were prepared by IRPP at ambient temperature. • High imprinting factor, high selectivity, and rapid binding kinetics were achieved. • Selective solid-phase extraction of glutathione from human urine samples

  5. Uranium isotopes determination in urine samples using alpha spectrometry and ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, Mychelle M.L.; Maihara, Vera A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Tine, Fernanda D.; Santos, Sandra M.C.; Bonifacio, Rodrigo L.; Taddei, Maria HelenaT. [Comissao Nacional de Energia Nuclear (LAPOC/CNEN-MG), Pocos de Caldas, MG (Brazil). Laboratorio de Pocos de Caldas

    2015-07-01

    The action of determining the concentration of uranium isotopes in biological samples, 'in vitro' bioassay, is an indirect method for evaluating the incorporation and quantification of these radionuclides internally deposited. When incorporated, these radionuclides tend to be disposed through excretion, with urine being the main source of data because it can be easily collected and analyzed. The most widely used methods for determination of uranium isotopes ({sup 234}U, {sup 235}U and {sup 238}U) are Alpha Spectrometry and ICP-MS. This work presents a comparative study for the determination of uranium isotopes using these two methodologies in real samples from occupationally exposed workers. In order to validate the methodology, a sample of the intercomparison exercise organized by PROCORAD (Association pour la Promotion du Controle de Qualite des Analyses de Biologie Medicale em Radiotoxicologie) was used, and the results were statistically compared applying the Student's t-test. (author)

  6. Performance of polymerase chain reaction for the diagnosis of cystic echinococcosis using serum, urine, and cyst fluid samples.

    Science.gov (United States)

    Chaya, Dr; Parija, Subhash Chandra

    2014-01-01

    Cystic echinococcosis (CE) is a chronic zoonosis which presents with variable clinical manifestations. Currently the diagnosis of this disease is based on radiological findings and serological tests which lack specificity. Although antigen detection from the cyst fluid is the most specific, it is seldom done due to the complications involved. Detecting the presence of Echinococcus granulosus specific deoxyribonucleic acid (DNA) by the polymerase chain reaction (PCR) could provide a definitive diagnosis of CE. An in-house PCR assay was devised to detect E. granulosus specific DNA in serum, urine and hydatid cyst fluid. The ability of the PCR to detect E. granulosus in the above mentioned samples were observed in comparison with other antigen and antibody detection tests. Serum samples from surgically confirmed patients of CE with ruptured cysts contained the corresponding DNA while the in the majority of cases who had an intact cyst had no DNA of E. granulosus in their serum. DNA of E. granulosus was not found to be excreted in urine. PCR performed equal to antigen detection ELISA while testing hydatid cyst fluid samples. Serum and urine might not serve as useful samples for the molecular diagnosis of cystic echinococcosis. However, PCR can be useful on serum samples to detect ruptured hydatid cysts and on hydatid cyst fluid to confirm the parasitic diagnosis.

  7. Ionic Liquid Dispersive Liquid-Liquid Microextraction Method for the Determination of Irinotecan, an Anticancer Drug, in Water and Urine Samples Using UV-Vis Spectrophotometry.

    Science.gov (United States)

    Uysal, Deniz; Karadaş, Cennet; Kara, Derya

    2017-05-01

    A new, simple, efficient, and environmentally friendly ionic liquid dispersive liquid-liquid microextraction method was developed for the determination of irinotecan, an anticancer drug, in water and urine samples using UV-Vis spectrophotometry. The ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate was used as the extraction solvent, and ethanol was used as the disperser solvent. The main parameters affecting the extraction efficiency, including sample pH, volume of the ionic liquid, choice of the dispersive solvent and its volume, concentration of NaCl, and extraction and centrifugation times, were investigated and optimized. The effect of interfering species on the recovery of irinotecan was also examined. Under optimal conditions, the LOD (3σ) was 48.7 μg/L without any preconcentration. Because the urine sample was diluted 10-fold, the LOD for urine would be 487 μg/L. However, this could be improved 16-fold if preconcentration using a 40 mL aliquot of the sample is used. The proposed method was successfully applied to the determination of irinotecan in tap water, river water, and urine samples spiked with 10.20 mg/L for the water samples and 8.32 mg/L for the urine sample. The average recovery values of irinotecan determined were 99.1% for tap water, 109.4% for river water, and 96.1% for urine.

  8. EVALUATION OF DISPOSABLE DIAPERS FOR QUANTATIVE MEASUREMENTS OF PESTICIDE METABOLITES AND CREATININE IN URINE SAMPLES

    Science.gov (United States)

    This project consisted of a laboratory study to evaluate an extraction and analysis method for quantifying biomarkers of pesticide exposure and creatinine in urine samples collected with commercially-available disposable diapers. For large exposure studies, such as the National ...

  9. Spectrophotometric Determination of Lamotrigine in Pharmaceutical Preparations and Urine Samples Using Bromothymol Blue and Bromophenol Blue

    International Nuclear Information System (INIS)

    Najib, F.M.; Aziz, K.H.H.

    2013-01-01

    Two simple and sensitive spectrophotometric methods have been developed for the determination of the antiepileptic drug lamotrigine (LMT) in pharmaceutical preparations and urine samples. The methods are based on the interaction of LMT with two sulphonphthalein dyes, namely, bromothymol blue (BTB) and bromophenol blue (BPB) in dichloromethane (DCM) medium to form stable and yellow-colored ion-pairs with λ max 410 and 413 nm respectively. The ion-pair LMT-BPB has been extracted from aqueous solutions at pH 3.25±0.25 using DCM; while LMT-BTB ion-pair was directly prepared in DCM. Interferences from the compounds of the urine samples, in case of LMT-BPB were removed using a suppressing solution (S.S.) prepared from the salts of the interfering ions. In LMT-BTB method, the urine of normal person not taking LMT, was used as a blank to remove the effect of interferences. Under optimum conditions, the calibration curve of LMT-BTB was linear over the range of 1-12 μg.ml -1 , ε=1.97x10 4 L.mole -1 .cm -1 , r 2 = 0.9983, and D.L of 0.13 μg.ml -1 . The corresponding values for (LMT-BPB) ion-pair were 0.5-12 μg.ml -1 linear range, ε=1.92x10 4 , r 2 = 0.9980, and D.L= 0.24 μg.ml -1 . The stoichiometry of the ion-pairs were found to be 1:1, based on Jobs, mole ratio and slope ratio methods. The recoveries (%R) for both methods were in the range of 97-101.8 % and 95-97.1 % with RSD≤1.68 and 3.1 % respectively. For LMT- spiked urine samples, the recoveries were 98.5-106.6 % with RSD≤1.66 %. Interferences from phenobarbital and carbamazepine were in the range of 25-40 folds. Statistical comparison of the results with a published method using F and t-tests showed no significant differences between each of the two methods and the reported one at 95 % confidence level. A standard addition method, gave high accuracy with LMT-BPB method. The proposed methods were successfully applied for the determination of LMT in pharmaceutical preparation and urine samples. (author)

  10. Significant increase in cultivation of Gardnerella vaginalis, Alloscardovia omnicolens, Actinotignum schaalii, and Actinomyces spp. in urine samples with total laboratory automation.

    Science.gov (United States)

    Klein, Sabrina; Nurjadi, Dennis; Horner, Susanne; Heeg, Klaus; Zimmermann, Stefan; Burckhardt, Irene

    2018-04-13

    While total laboratory automation (TLA) is well established in laboratory medicine, only a few microbiological laboratories are using TLA systems. Especially in terms of speed and accuracy, working with TLA is expected to be superior to conventional microbiology. We compared in total 35,564 microbiological urine cultures with and without incubation and processing with BD Kiestra TLA for a 6-month period each retrospectively. Sixteen thousand three hundred thirty-eight urine samples were analyzed in the pre-TLA period and 19,226 with TLA. Sixty-two percent (n = 10,101/16338) of the cultures processed without TLA and 68% (n = 13,102/19226) of the cultures processed with TLA showed growth. There were significantly more samples with two or more species per sample and with low numbers of colony forming units (CFU) after incubation with TLA. Regarding the type of bacteria, there were comparable amounts of Enterobacteriaceae in the samples, slightly less non-fermenting Gram-negative bacteria, but significantly more Gram-positive cocci, and Gram-positive rods. Especially Alloscardivia omnicolens, Gardnerella vaginalis, Actinomyces spp., and Actinotignum schaalii were significantly more abundant in the samples incubated and processed with TLA. The time to report was significantly lower in the TLA processed samples by 1.5 h. We provide the first report in Europe of a large number of urine samples processed with TLA. TLA showed enhanced growth of non-classical and rarely cultured bacteria from urine samples. Our findings suggest that previously underestimated bacteria may be relevant pathogens for urinary tract infections. Further studies are needed to confirm our findings.

  11. Investigations of the microbial transformation of cortisol to prednisolone in urine samples.

    Science.gov (United States)

    Bredehöft, Michael; Baginski, Rainer; Parr, Maria-Kristina; Thevis, Mario; Schänzer, Wilhelm

    2012-03-01

    Doping control samples are normally collected under non-sterile conditions and sometimes, storage and transportation are influenced by parameters such as the temperature. Therefore, microbial contamination and subsequent alteration of a sample's composition are possible. Studies regarding sample collection in cattle breeding have already shown enzymatic transformation of endogenous testosterone to boldenone causing false-positive findings. The aim of the present study was to investigate whether positive doping cases with the synthetic corticosteroids prednisolone and prednisone may result from microbial transformation of the endogenous corticosteroids cortisol and cortisone, respectively. A method comprising parameters such as pH values and screening results for synthetic glucocorticosteroids as well as incubation experiments followed by liquid chromatographic and mass spectrometric analysis was employed to test for contaminating germs with Δ(1)-dehydrogenase activity. Over 700 urine samples comprising inpatient and doping control specimens were investigated. In none of them, 1,2-dehydrogenating activity was confirmed. These findings are in accordance with other studies. However, the problem of microbial alteration of doping control specimens with special respect to 1,2-dehydrogenation must not be underestimated. Article from a special issue on steroids and microorganisms. Copyright © 2010 Elsevier Ltd. All rights reserved.

  12. Determination of piroxicam in pharmaceutical formulations and urine samples using europium-sensitized luminescence

    Energy Technology Data Exchange (ETDEWEB)

    Al-Kindy, Salma M.Z. [Department of Chemistry, College of Science, P.O. Box 36, Al-Khod 123, Sultan Qaboos University (Oman)], E-mail: alkindy@squ.edu.om; Suliman, Fakhr Eldin O.; Al-Wishahi, Aisha A.; Al-Lawati, Haidar A.J.; Aoudia, Muhammed [Department of Chemistry, College of Science, P.O. Box 36, Al-Khod 123, Sultan Qaboos University (Oman)

    2007-12-15

    A simple, selective and sensitive luminescence method for the assay of piroxicam (PX) in aqueous solution is developed. The method is based on the luminescence sensitization of europium (Eu{sup 3+}) by formation of ternary complex with PX in the presence of TOPO and Tween-80 as surfactant. The signal for Eu-PX-TOPO is monitored at {lambda}{sub ex}=359 nm and {lambda}{sub em}=615 nm. Optimum conditions for the formation of the complex in sequential injection analysis (SIA) were 0.01 M Tris buffer, pH 7.5, TOPO 5.0x10{sup -5} M, Tween-80 0.15% and 1.5 mM of Eu{sup 3+}, which allows the determination of 100-1000 ppb of PX with limit of detection (LOD) of 29 ppb. The relative standard deviations of the method range between 0.5% and 3.9% indicating excellent reproducibility of the method. The proposed method was successfully applied for the assay of PX in pharmaceutical formulations and in urine samples. Average recoveries of 100.8{+-}1.7% was obtained in tablet, whereas a recovery of 97.5{+-}2.0% was obtained for the total PX (PX+hydoxy-PX) in urine sample.

  13. Determination of piroxicam in pharmaceutical formulations and urine samples using europium-sensitized luminescence

    International Nuclear Information System (INIS)

    Al-Kindy, Salma M.Z.; Suliman, Fakhr Eldin O.; Al-Wishahi, Aisha A.; Al-Lawati, Haidar A.J.; Aoudia, Muhammed

    2007-01-01

    A simple, selective and sensitive luminescence method for the assay of piroxicam (PX) in aqueous solution is developed. The method is based on the luminescence sensitization of europium (Eu 3+ ) by formation of ternary complex with PX in the presence of TOPO and Tween-80 as surfactant. The signal for Eu-PX-TOPO is monitored at λ ex =359 nm and λ em =615 nm. Optimum conditions for the formation of the complex in sequential injection analysis (SIA) were 0.01 M Tris buffer, pH 7.5, TOPO 5.0x10 -5 M, Tween-80 0.15% and 1.5 mM of Eu 3+ , which allows the determination of 100-1000 ppb of PX with limit of detection (LOD) of 29 ppb. The relative standard deviations of the method range between 0.5% and 3.9% indicating excellent reproducibility of the method. The proposed method was successfully applied for the assay of PX in pharmaceutical formulations and in urine samples. Average recoveries of 100.8±1.7% was obtained in tablet, whereas a recovery of 97.5±2.0% was obtained for the total PX (PX+hydoxy-PX) in urine sample

  14. Determination of uranium in urine samples for workers in the phosphoric acid purification using fluorimetry technique

    International Nuclear Information System (INIS)

    Kharita, M. H.; Sakhita, Kh.; Aldalal, Z.

    2003-10-01

    There is probability of exposure to uranium for workers in the phosphoric acid purification (internal exposure) by inhalation, and the deposition of this uranium in organs and tissues, and the consequence excreation out of the body by perspiration or urine. This study focuses on the determination of uranium in urine samples of workers. All results seem to be under the detection limit of the method, therefore no routine monitoring is required. (author)

  15. Rapid determination of 239Pu in urine samples using molecular recognition technology product AnaLigRPu-02 gel

    International Nuclear Information System (INIS)

    Silvia Dulanska; Boris Remenec; Jan Bilohuscin; Miroslav Labaska; Bianka Horvathova; Andrej Matel

    2013-01-01

    This paper describes the use of IBC's AnaLig R Pu-02 molecular recognition technology product to effectively and selectively pre-concentrate, separate and recover plutonium from urine samples. This method uses two-stage column separations consisting of two different commercial products, Eichrom's Pre-filter Material and AnaLig R Pu-02 resin from IBC Advanced Technologies. By eliminating the co-precipitation techniques and the ashing steps to remove residual organics, the analysis time was reduced significantly. The method was successfully tested by adding known activities of reference solutions of 242 Pu and 239 Pu to urine samples. (author)

  16. Application of dried spot cards as a rapid sample treatment method for determining hydroxytyrosol metabolites in human urine samples. Comparison with microelution solid-phase extraction.

    Science.gov (United States)

    Serra, Aida; Rubió, Laura; Macià, Alba; Valls, Rosa-M; Catalán, Úrsula; de la Torre, Rafael; Motilva, Maria-José

    2013-11-01

    Two different rapid sample pretreatment strategies, dried spot cards, and microelution solid-phase extraction plates (μSPE), with ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) have been developed and validated for the determination of hydroxytyrosol and its metabolites in spiked human urine samples. Hydroxytyrosol, hydroxytyrosol-3'-O-glucuronide, hydroxytyrosol-4'-O-glucuronide, hydroxytyrosol-3-O-sulphate, and homovanillic alcohol-4'-O-glucuronide were used as the target compounds. Using the FTA DMPK-A dried urine spot card under optimum conditions, with 5 μL of preconcentrated urine volume and 100 μL of methanol/water (50/50, v/v) as the elution solvent, the extraction recovery (%R) of the compounds studied was higher than 80%, and the matrix effect (%ME) was less than 8%. The stability of these cards and punching at the centre or side of the card were also studied, obtaining an excellent stability after 7 days of storage and complete homogeneity across the surface of the dried drop. The different μSPE parameters that affect the efficiency were also studied, and under optimum conditions, the %R and the %ME were higher than 70% and lower than 17%, respectively. The linearity range in dried urine spot cards was 2.5-20 μM for all the metabolites, with the exception of hydroxytyrosol-3-O-sulphate and hydroxytyrosol, which were 0.3-70 μM and 2.5-50 μM respectively. With regards to μSPE, the linearity range was 0.5-5 μM for all the studied compounds, except for hydroxytyrosol-3-O-sulphate, which was 0.08-5 μM. The quantification limits (LOQs) were 0.3-2.5 μM and 0.08-0.5 μM in dried spot cards and in μSPE, respectively. The two developed methods were then applied and compared for determining hydroxytyrosol and its metabolites in human 24 h-urine samples after a sustained consumption (21 days) of a phenol-enriched virgin olive oil. The metabolites identified were hydroxytyrosol in its glucuronide and sulphate

  17. Two-Dimensional Capillary Electrophoresis with On-Line Sample Preparation and Cyclodextrin Separation Environment for Direct Determination of Serotonin in Human Urine.

    Science.gov (United States)

    Piešťanský, Juraj; Maráková, Katarína; Mikuš, Peter

    2017-10-07

    An advanced two-dimensional capillary electrophoresis method, based on on-line combination of capillary isotachophoresis and capillary zone electrophoresis with cyclodextrin additive in background electrolyte, was developed for effective determination of serotonin in human urine. Hydrodynamically closed separation system and large bore capillaries (300-800 µm) were chosen for the possibility to enhance the sample load capacity, and, by that, to decrease limit of detection. Isotachophoresis served for the sample preseparation, defined elimination of sample matrix constituents (sample clean up), and preconcentration of the analyte. Cyclodextrin separation environment enhanced separation selectivity of capillary zone electrophoresis. In this way, serotonin could be successfully separated from the rest of the sample matrix constituents migrating in capillary zone electrophoresis step so that human urine could be directly (i.e., without any external sample preparation) injected into the analyzer. The proposed method was successfully validated, showing favorable parameters of sensitivity (limit of detection for serotonin was 2.32 ng·mL -1 ), linearity (regression coefficient higher than 0.99), precision (repeatability of the migration time and peak area were in the range of 0.02-1.17% and 5.25-7.88%, respectively), and recovery (ranging in the interval of 90.0-93.6%). The developed method was applied for the assay of the human urine samples obtained from healthy volunteers. The determined concentrations of serotonin in such samples were in the range of 12.4-491.2 ng·mL -1 that was in good agreement with literature data. This advanced method represents a highly effective, reliable, and low-cost alternative for the routine determination of serotonin as a biomarker in human urine.

  18. Preparation of magnetic ODS-PAN thin-films for microextraction of quetiapine and clozapine in plasma and urine samples followed by HPLC-UV detection.

    Science.gov (United States)

    Li, Dan; Zou, Juan; Cai, Pei-Shan; Xiong, Chao-Mei; Ruan, Jin-Lan

    2016-06-05

    In this study, conventional thin-film microextraction (TFME) was endowed with magnetic by introducing superparamagnetic SiO2@Fe3O4 nanoparticles in thin-films. Novel magnetic octadecylsilane (ODS)-polyacrylonitrile (PAN) thin-films were prepared by spraying, and used for the microextraction of quetiapine and clozapine in plasma and urine samples, followed by the detection of HPLC-UV. The influencing factors on the extraction efficiency of magnetic ODS-PAN TFME, including pH, extraction time, desorption solvent, desorption time, and ion strength were investigated systematically. Under the optimal conditions, both analytes showed good linearity over ranges of 0.070-9.000μgmL(-1) and 0.012-9.000μgmL(-1) in plasma and urine samples, respectively, with correlation coefficients (R(2)) above 0.9990. Limits of detection (LODs) for quetiapine in plasma and urine samples were 0.013 and 0.003μgmL(-1), respectively. LODs for clozapine in plasma and urine samples were 0.015 and 0.003μgmL(-1), respectively. The relative standard deviations (RSDs) for quetiapine and clozapine were less than 9.23%. After the validation, the protocol was successfully applied for the determination of quetiapine and clozapine in patients' plasma and urine samples with satisfactory recoveries between 99-110%. The proposed magnetic ODS-PAN TFME was very simple, fast and easy to handle. It showed high potential as a powerful pretreatment technology for routine therapeutic drug monitoring (TDM) in plasma and urine samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. A needle extraction utilizing a molecularly imprinted-sol-gel xerogel for on-line microextraction of the lung cancer biomarker bilirubin from plasma and urine samples.

    Science.gov (United States)

    Moein, Mohammad Mahdi; Jabbar, Dunia; Colmsjö, Anders; Abdel-Rehim, Mohamed

    2014-10-31

    In the present work, a needle trap utilizing a molecularly imprinted sol-gel xerogel was prepared for the on-line microextraction of bilirubin from plasma and urine samples. Each prepared needle could be used for approximately one hundred extractions before it was discarded. Imprinted and non-imprinted sol-gel xerogel were applied for the extraction of bilirubin from plasma and urine samples. The produced molecularly imprinted sol-gel xerogel polymer showed high binding capacity and fast adsorption/desorption kinetics for bilirubin in plasma and urine samples. The adsorption capacity of molecularly imprinted sol-gel xerogel polymer was approximately 60% higher than that of non-imprinted polymer. The effect of the conditioning, washing and elution solvents, pH, extraction time, adsorption capacity and imprinting factor were investigated. The limit of detection and the lower limit of quantification were set to 1.6 and 5nmolL(-1), respectively using plasma or urine samples. The standard calibration curves were obtained within the concentration range of 5-1000nmolL(-1) in both plasma and urine samples. The coefficients of determination values (R(2)) were ≥0.998 for all runs. The extraction recovery was approximately 80% for BR in the human plasma and urine samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Rapid screening of selective serotonin re-uptake inhibitors in urine samples using solid-phase microextraction gas chromatography-mass spectrometry.

    Science.gov (United States)

    Salgado-Petinal, Carmen; Lamas, J Pablo; Garcia-Jares, Carmen; Llompart, Maria; Cela, Rafael

    2005-07-01

    In this paper a solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) method is proposed for a rapid analysis of some frequently prescribed selective serotonin re-uptake inhibitors (SSRI)-venlafaxine, fluvoxamine, mirtazapine, fluoxetine, citalopram, and sertraline-in urine samples. The SPME-based method enables simultaneous determination of the target SSRI after simple in-situ derivatization of some of the target compounds. Calibration curves in water and in urine were validated and statistically compared. This revealed the absence of matrix effect and, in consequence, the possibility of quantifying SSRI in urine samples by external water calibration. Intra-day and inter-day precision was satisfactory for all the target compounds (relative standard deviation, RSD, detection limits achieved were detected and tentatively identified.

  1. High throughput-screening of animal urine samples: It is fast but is it also reliable?

    Science.gov (United States)

    Kaufmann, Anton

    2016-05-01

    Advanced analytical technologies like ultra-high-performance liquid chromatography coupled to high resolution mass spectrometry can be used for veterinary drug screening of animal urine. The technique is sufficiently robust and reliable to detect veterinary drugs in urine samples of animals where the maximum residue limit of these compounds in organs like muscle, kidney, or liver has been exceeded. The limitations and possibilities of the technique are discussed. The most critical point is the variability of the drug concentration ratio between the tissue and urine. Ways to manage the false positive and false negatives are discussed. The capability to confirm findings and the possibility of semi-targeted analysis are also addressed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  2. Clenbuterol storage stability in the bovine urine and liver samples used for European official control in the azores islands (portugal).

    Science.gov (United States)

    Pinheiro, Isabel; Jesuino, Bruno; Barbosa, Jorge; Ferreira, Humberto; Ramos, Fernando; Matos, José; da Silveira, Maria Irene Noronha

    2009-02-11

    Clenbuterol is a well-known growth promoter, illegally used in farm animals, especially in cattle. Samples collected for the screening of beta(2)-agonist residues in Portuguese Azores Islands must travel through all the nine islands until they reach Azores Central Laboratory. If any suspicious sample is detected, it must be further transported to the National Reference Laboratory in Lisbon for confirmation. As a consequence of these circumstances, samples are submitted to different transport and storage times, as well as different temperature conditions and in some cases successive freezing and thawing cycles. As clenbuterol is the most detected beta(2)-agonist growth promoter in the Portuguese Residue Monitoring Plan, studies were conducted on the stability of this compound in incurred samples (bovine liver and urine) at +4, -20 and -60 degrees C over time. Samples kept at -20 degrees C were also analyzed over time after successive freezing and thawing cycles. The analyses of clenbuterol over time were performed by gas chromatography-mass spectrometry (GC-MS) with selected ion monitoring (SIM). Clenbuterol in incurred urine and liver samples was significantly stable up to 20 weeks at -20 and -60 degrees C and after, at least, six consecutive freezings and thawings. At +4 degrees C, clenbuterol remained stable, at least until 12 weeks in urine and up to 20 weeks in liver.

  3. Detection of recombinant EPO in blood and urine samples with EPO WGA MAIIA, IEF and SAR-PAGE after microdose injections.

    Science.gov (United States)

    Dehnes, Yvette; Shalina, Alexandra; Myrvold, Linda

    2013-01-01

    The misuse of microdoses of performance enhancing drugs like erythropoietin (EPO) constitutes a major challenge in doping analysis. When injected intravenously, the half-life of recombinant human EPO (rhEPO) like epoetin alfa, beta, and zeta is only a few hours and hence, the window for direct detection of rhEPO in urine is small. In order to investigate the detection window for rhEPO directly in blood and urine with a combined affinity chromatography and lateral flow immunoassay (EPO WGA MAIIA), we recruited nine healthy people who each received six intravenously injected microdoses (7.5 IU/kg) of NeoRecormon (epoetin beta) over a period of three weeks. Blood and urine samples were collected in the days following the injections and analyzed with EPO WGA MAIIA as well as the current validated methods for rhEPO; isoelectric focusing (IEF) and sarcosyl polyacrylamide gel electrophoresis (SAR-PAGE). For samples collected 18 h after a microdose, the sensitivity of the EPO WGA MAIIA assay was 100% in plasma and 87.5% in urine samples at the respective 98% specificity threshold levels. In comparison, the sensitivity in plasma and urine was 75% and 100%, respectively, with IEF, and 87.5% in plasma and 100% in urine when analyzed with SAR-PAGE. We conclude that EPO WGA MAIIA is a sensitive assay for the detection of rhEPO, with the potential of being a fast, supplemental screening assay for use in doping analysis.

  4. Hollow-fiber micro-extraction combined with HPLC for the determination of sitagliptin in urine samples

    Directory of Open Access Journals (Sweden)

    Rezaee Raheme

    2015-01-01

    Full Text Available This study successfully developed a three-phase hollow-fiber liquid phase micro extraction coupled with high performance liquid chromatography for determination of trace levels of an anti-diabetic drug, sitagliptin (STG, in urine samples. Sitagliptin was extracted from 15 mL of the basic sample solution with a pH of 8.5 into an organic extracting solvent (n-octanol impregnated in the pores of a hollow fiber and then back extracted into an acidified aqueous solution in the lumen of the hollow fiber with a pH of 3. After extraction, 20 µL of the acceptor phase was injected into HPLC. In order to obtain high extraction efficiency, the parameters affecting the HF-LPME including pH of the source and receiving phases, type of organic phase, ionic strength, stirring rate, extraction time, the volume ratio of donor phase to acceptor phase and temperature were studied and optimized. Under the optimized conditions, enrichment factors up to 88 were achieved and the relative standard deviation of the method was in the range of 3 % to 6%. The results indicated that HF-LPME method has an excellent clean-up capacity and a high preconcentration factor and can serve as a simple and sensitive method for monitoring the drug in the urine samples.

  5. Urine concentrations of oral salbutamol in samples collected after intense exercise in endurance athletes

    DEFF Research Database (Denmark)

    Hostrup, Morten; Kalsen, Anders; Auchenberg, Michael

    2014-01-01

    Our objective was to investigate urine concentrations of 8 mg oral salbutamol in samples collected after intense exercise in endurance athletes. Nine male endurance athletes with a VO2max of 70.2 ± 5.9 mL/min/kg (mean ± SD) took part in the study. Two hours after administration of 8 mg oral...

  6. Identification and quantification of flavonoids in human urine samples by column switching liquid chromatography coupled to atmospheric pressure chemical ionization mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, S. E.; Freese, R.; Cornett, Claus

    2000-01-01

    A rapid and sensitive high-performance liquid chromatographic mass spectrometric (HPLC-MS) method is described for the determination and quantification of 12 dietary flavonoid glycosides and aglycons in human urine samples. Chromatographic separation of the analytes of interest was achieved...... by column-switching, using the first column (a Zorbax 300SB C-3 column) for sample cleanup and eluting the heart-cut flavonoid fraction onto the second column (a Zorbax SE C-18 column) for separation and detection by ultraviolet and atmospheric pressure chemical ionization MS using single ion monitoring...... of variation for the analysis of the 12 different flavonoids in quality control urine samples were 12.3% on average (range 11.0-13.7%, n = 24, reproducibility) and the repeatability of the assay were 5.0% (mean, range 0.1-14.8%, it = 12). A subset of 10 urine samples from a human dietary intervention study...

  7. Hollow-fiber-supported liquid phase microextraction with in situ derivatization and gas chromatography-mass spectrometry for determination of chlorophenols in human urine samples.

    Science.gov (United States)

    Ito, Rie; Kawaguchi, Migaku; Honda, Hidehiro; Koganei, Youji; Okanouchi, Noriya; Sakui, Norihiro; Saito, Koichi; Nakazawa, Hiroyuki

    2008-09-01

    A simple and highly sensitive method that involves hollow-fiber-supported liquid phase microextraction (HF-LPME) with in situ derivatization and gas chromatography-mass spectrometry (GC-MS) was developed for the determination of chlorophenols (CPs) such as 2,4-dichlorophenol (DCP), 2,4,6-trichlorophenol (TrCP), 2,3,4,6-tetrachlorophenol (TeCP) and pentachlorophenol (PCP) in human urine samples. Human urine samples were enzymatically de-conjugated with beta-glucuronidase and sulfatase. After de-conjugation, HF-LPME with in situ derivatization was performed. After extraction, 2 microl of extract was carefully withdrawn into a syringe and injected into the GC-MS system. The limits of detection (S/N=3) and quantification (S/N>10) of CPs in the human urine samples are 0.1-0.2 ng ml(-1) and 0.5-1 ng ml(-1), respectively. The calibration curve for CPs is linear with a correlation coefficient of >0.99 in the range of 0.5-500 ng ml(-1) for DCP and TrCP, and of 1-500 ng ml(-1) for TeCP and PCP, respectively. The average recoveries of CPs (n=6) in human urine samples are 81.0-104.0% (R.S.D.: 1.9-6.6%) with correction using added surrogate standards. When the proposed method was applied to human urine samples, CPs were detected at sub-ng ml(-1) level.

  8. Analytical Validation of a New Enzymatic and Automatable Method for d-Xylose Measurement in Human Urine Samples

    Directory of Open Access Journals (Sweden)

    Israel Sánchez-Moreno

    2017-01-01

    Full Text Available Hypolactasia, or intestinal lactase deficiency, affects more than half of the world population. Currently, xylose quantification in urine after gaxilose oral administration for the noninvasive diagnosis of hypolactasia is performed with the hand-operated nonautomatable phloroglucinol reaction. This work demonstrates that a new enzymatic xylose quantification method, based on the activity of xylose dehydrogenase from Caulobacter crescentus, represents an excellent alternative to the manual phloroglucinol reaction. The new method is automatable and facilitates the use of the gaxilose test for hypolactasia diagnosis in the clinical practice. The analytical validation of the new technique was performed in three different autoanalyzers, using buffer or urine samples spiked with different xylose concentrations. For the comparison between the phloroglucinol and the enzymatic assays, 224 urine samples of patients to whom the gaxilose test had been prescribed were assayed by both methods. A mean bias of −16.08 mg of xylose was observed when comparing the results obtained by both techniques. After adjusting the cut-off of the enzymatic method to 19.18 mg of xylose, the Kappa coefficient was found to be 0.9531, indicating an excellent level of agreement between both analytical procedures. This new assay represents the first automatable enzymatic technique validated for xylose quantification in urine.

  9. Quantification of human polyomavirus JC virus load in urine and blood samples of healthy tribal populations of North-Eastern part of West Bengal, India.

    Science.gov (United States)

    Chattaraj, S; Bera, N K; Dutta, C; Bhattacharjee, S

    2015-01-01

    Human polyomavirus JC (JCV) is a widespread human virus with profound pathogenic potential. A study was undertaken to quantify JCV load in urine and peripheral blood samples of immunocompetent, apparently healthy tribal individuals of North-Eastern part of West Bengal, India for the first time. One hundred and thirteen samples of urine or blood were collected from different tribal groups of this region. For the quantitative estimation of the viral load in each sample, real-time polymerase chain reaction method using the SYBR Green dye was employed. The viral load estimated was found in the range between 3.5 × 102 and 2.12 × 106 copies/ml of samples having a mean and median viral copy numbers of 8.67 × 105 and 9.19 × 105 copies/ml of sample respectively. The mean viral DNA load in urine samples of the studied immunocompetent population was found to be higher than that found in a study conducted in the USA, but lower than similar groups of Italy and healthy adult women in the USA. However when compared with median values of viral DNA loads in urine samples of immunocompetent human subjects of Kuwait, Portugal, and Switzerland the observed viral DNA load was found to be substantially higher.

  10. Bioassay techniques for 55Fe in urine samples

    International Nuclear Information System (INIS)

    Cregan, S.P.; Leon, J.W.; Linauskas, S.H.

    1993-11-01

    Solvent extraction, ion chromatography and several rapid screening methods were developed and evaluated for 55 Fe bioassay applications. Isopropyl ether and TNOA column extractions had radiochemical recoveries exceeding 90%. These were very reproducible with a coefficient of variation less than 5%. Screening techniques investigated included direct counting of ashed urine solids, and Fe(OH) 3 . precipitated from urine. The sensitivities (2-50 Bq/d urine) of the screening methods were usually limited by the effective urine volume that could be counted in a liquid scintillation counter. The reference isopropyl ether and chromatography methods could easily achieve sensitivities well below the 1 Bq/d urine output target. (author). 49 refs., 3 tabs., 5 figs

  11. Multisite Direct Determination of the Potential for Environmental Contamination of Urine Samples Used for Diagnosis of Sexually Transmitted Infections.

    Science.gov (United States)

    Andersson, Patiyan; Tong, Steven Y C; Lilliebridge, Rachael A; Brenner, Nicole C; Martin, Louise M; Spencer, Emma; Delima, Jennifer; Singh, Gurmeet; McCann, Frances; Hudson, Carolyn; Johns, Tracy; Giffard, Philip M

    2014-09-01

    The detection of a sexually transmitted infection (STI) agent in a urine specimen from a young child is regarded as an indicator of sexual contact. False positives may conceivably arise from the transfer of environmental contaminants in clinic toilet or bathroom facilities into urine specimens. The potential for contamination of urine specimens with environmental STI nucleic acid was tested empirically in the male and female toilets or bathrooms at 10 Northern Territory (Australia) clinics, on 7 separate occasions at each. At each of the 140 experiments, environmental contamination with Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis nucleic acid contamination was determined by swabbing 10 locations, and urine collection was simulated 5 times, using a (1) synthetic urine surrogate and (2) a standardized finger contamination procedure. The most contaminated toilets and bathrooms were in remote Indigenous communities. No contamination was found in the Northern Territory Government Sexual Assault Referral Centre clinics, and intermediate levels of contamination were found in sexual health clinics and in clinics in regional urban centres. The frequency of surrogate urine sample contamination was low but non-zero. For example, 4 of 558 of the urine surrogate specimens from remote clinics were STI positive. This is by far the largest study addressing the potential environmental contamination of urine samples with STI agents. Positive STI tests arising from environmental contamination of urine specimens cannot be ruled out. The results emphasize that urine specimens from young children taken for STI testing should be obtained by trained staff in clean environments, and duplicate specimens should be obtained if possible. © The Author 2013. Published by Oxford University Press on behalf of the Pediatric Infectious Diseases Society.

  12. Detection of dopamine in non-treated urine samples using glassy carbon electrodes modified with PAMAM dendrimer-Pt composites

    International Nuclear Information System (INIS)

    Garcia, M.G.; Armendariz, G.M.E.; Godinez, Luis A.; Torres, J.; Sepulveda-Guzman, S.; Bustos, E.

    2011-01-01

    Composites of hydroxyl-terminated PAMAM dendrimers, generation 4.0 (64 peripheral OH groups) containing Pt nanoparticles were synthesized at different reaction times using a microwave reactor. The synthetic procedure resulted in dendrimer encapsulated nanoparticles of Pt (DENs-Pt) of 1.53 ± 0.17 nm diameter that was calculated from transmission electron microscopy, and the Pt nanoparticles had single crystal plane in (1 1 1) orientation determinate by selective area diffraction. Each composite was electrochemically immobilized on a pre-functionalized glassy carbon (GC) electrode that was incorporated as a flow injection amperometric (FIA) detector, for the selective detection and quantification of dopamine (DA) in untreated urine samples. Comparison of the analytical performance of the novel electrochemical detector revealed that the DENs-Pt modified GC electrode with the composite synthesized for 30 min in the microwave reactor, showed the best response for the detection of DA in samples of non-treated urine, being the detection and quantification limits smaller (19 and 9 ppb, respectively) than those corresponding to the naked a GC electrode (846 and 423 ppb, respectively) using the FIA detector. In addition, it was found that this electroanalytical approach suffers minimal matrix effects that arise in the analysis of DA in untreated samples of urine.

  13. Detection of dopamine in non-treated urine samples using glassy carbon electrodes modified with PAMAM dendrimer-Pt composites

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, M.G. [Laboratory of Bioelectrochemistry, Centro de Investigacion y Desarrollo Tecnologico en Electroquimica, S. C., Parque Tecnologico, Queretaro, Sanfandila, Pedro Escobedo 76703, Queretaro (Mexico); Department of Chemistry, Universidad de Guanajuato, Cerro de la Venada S/N Col. Pueblito de Rocha, 36040 Guanajuato, Gto (Mexico); Armendariz, G.M.E.; Godinez, Luis A.; Torres, J. [Laboratory of Bioelectrochemistry, Centro de Investigacion y Desarrollo Tecnologico en Electroquimica, S. C., Parque Tecnologico, Queretaro, Sanfandila, Pedro Escobedo 76703, Queretaro (Mexico); Sepulveda-Guzman, S. [Centro de Innovacion, Investigacion y Desarrollo en Ingenieria y Tecnologia, Facultad de Ingenieria Mecanica y Electrica, Universidad Autonoma de Nuevo Leon, Av. Universidad, San Nicolas de los Garza, Nuevo Leon, 66451 Nuevo Leon (Mexico); Bustos, E., E-mail: ebustos@cideteq.mx [Laboratory of Bioelectrochemistry, Centro de Investigacion y Desarrollo Tecnologico en Electroquimica, S. C., Parque Tecnologico, Queretaro, Sanfandila, Pedro Escobedo 76703, Queretaro (Mexico)

    2011-09-01

    Composites of hydroxyl-terminated PAMAM dendrimers, generation 4.0 (64 peripheral OH groups) containing Pt nanoparticles were synthesized at different reaction times using a microwave reactor. The synthetic procedure resulted in dendrimer encapsulated nanoparticles of Pt (DENs-Pt) of 1.53 {+-} 0.17 nm diameter that was calculated from transmission electron microscopy, and the Pt nanoparticles had single crystal plane in (1 1 1) orientation determinate by selective area diffraction. Each composite was electrochemically immobilized on a pre-functionalized glassy carbon (GC) electrode that was incorporated as a flow injection amperometric (FIA) detector, for the selective detection and quantification of dopamine (DA) in untreated urine samples. Comparison of the analytical performance of the novel electrochemical detector revealed that the DENs-Pt modified GC electrode with the composite synthesized for 30 min in the microwave reactor, showed the best response for the detection of DA in samples of non-treated urine, being the detection and quantification limits smaller (19 and 9 ppb, respectively) than those corresponding to the naked a GC electrode (846 and 423 ppb, respectively) using the FIA detector. In addition, it was found that this electroanalytical approach suffers minimal matrix effects that arise in the analysis of DA in untreated samples of urine.

  14. Determination of parent and hydroxy PAHs in personal PM{sub 2.5} and urine samples collected during Native American fish smoking activities

    Energy Technology Data Exchange (ETDEWEB)

    Motorykin, Oleksii [Department of Chemistry, Oregon State University, Corvallis, OR 97331 (United States); Schrlau, Jill; Jia, Yuling [Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, OR 97331 (United States); Harper, Barbara; Harris, Stuart [Department of Science and Engineering, Confederated Tribes of the Umatilla Indian Reservation, Pendleton, OR 97801 (United States); Harding, Anna [School of Biological and Population Health Sciences, Oregon State University, Corvallis, OR 97331 (United States); Stone, David [Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, OR 97331 (United States); Kile, Molly [School of Biological and Population Health Sciences, Oregon State University, Corvallis, OR 97331 (United States); Sudakin, Daniel [Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, OR 97331 (United States); Massey Simonich, Staci L., E-mail: staci.simonich@orst.edu [Department of Chemistry, Oregon State University, Corvallis, OR 97331 (United States); Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, OR 97331 (United States)

    2015-02-01

    A method was developed for the measurement of 19 parent PAHs (PAHs) and 34 hydroxylated PAHs (OH-PAHs) in urine and personal air samples of particulate matter less than 2.5 μm in diameter (PM{sub 2.5}) using GC–MS and validated using NIST SRM 3672 (Organic Contaminants in Smoker's Urine) and SRM 3673 (Organic Contaminants in Nonsmoker's Urine). The method was used to measure PAHs and OH-PAHs in urine and personal PM{sub 2.5} samples collected from the operators of two different fish smoking facilities (tipi and smoke shed) burning two different wood types (alder and apple) on the Confederated Tribes of Umatilla Indian Reservation (CTUIR) while they smoked salmon. Urine samples were spiked with β-glucuronidase/arylsulfatase to hydrolyze the conjugates of OH-PAHs and the PAHs and OH-PAHs were extracted using Plexa and C18 solid phases, in series. The 34 OH-PAHs were derivatized using MTBSTFA, and the mixture was measured by GC–MS. The personal PM{sub 2.5} samples were extracted using pressurized liquid extraction, derivatized with MTBSTFA and analyzed by GC–MS for PAHs and OH-PAHs. Fourteen isotopically labeled surrogates were added to accurately quantify PAHs and OH-PAHs in the urine and PM{sub 2.5} samples and three isotopically labeled internal standards were used to calculate the recovery of the surrogates. Estimated detection limits in urine ranged from 6.0 to 181 pg/ml for OH-PAHs and from 3.0 to 90 pg/ml for PAHs, and, in PM{sub 2.5}, they ranged from 5.2 to 155 pg/m{sup 3} for OH-PAHs and from 2.5 to 77 pg/m{sup 3} for PAHs. The results showed an increase in OH-PAH concentrations in urine after 6 h of fish smoking and an increase in PAH concentrations in air within each smoking facility. In general, the PAH exposure in the smoke shed was higher than in the tipi and the PAH exposure from burning apple wood was higher than burning alder. - Highlights: • An analytical method was developed for the measurement of 19 PAHs and 34 OH-PAHs.

  15. Estimasi Sintesis Protein Mikrobia Rumen Menggunakan Ekskresi Derivat Purin dalam Urin dengan Teknik Spot Sampling pada Kambing Bligon dan Kambing Kejobong

    Directory of Open Access Journals (Sweden)

    Dianestu Putra

    2016-11-01

    Full Text Available This study were aimed to determine the correlation between concentration of purine derivatives (PD in spot sample with PD total excretion in Bligon and Kejobong goats and determine the appropriate sampling time, in order to predicting microbial protein synthesis in both breeds. Six male Bligon goats and six male Kejobong goats with age range from 8 to 14 months and body weight from 16 to 21 kg were placed in metabolism cages. Peanut straw and water were given to both groups of goats through ad libitum feeding and drinking. The study was done in 14 days for adaptation, 3 days for collection. Sample of feeds, feed residues, and feces were collected and then analyzed to determine dry matter and organic matter content. Spot urine and the total daily urine samples were also collected. Samples collection of spot sampling technique was run by taking the urine periodically with 3 hours intervals at 24 hours. Urine samples were analyzed for the content of creatinine and PD which includes allantoin, uric acid, xanthine, and hypoxanthine. Data were tested for the correlation between concentration of PD spot urine sample with total PD daily excretion. It is known that the concentration of PD and creatinine (µmol/L for Bligon were 1,418.40 and 202.85 respectively, while for Kejobong were 1,547.40 and 219.68 respectively. Total excretion of PD, allantoin, uric acid, xanthyne and hypoxanthine and creatinine (µmol/W0,75/day for Bligon were 114.14, 95.86, 17.31, 0.97, and 16.40 respectively, with microbial protein synthesis efficiency was 4.61 g N/kg degraded of organic matter in rumen (DOMR. Total excretion of PD allantoin, uric acid, xanthyne and hypoxanthine and creatinine (µmol/W0,75/day for Kejobong were 180.18, 158.17, 20.60, 1.40, and 24.87 respectively, with microbial protein synthesis efficiency was 6.90 g N/kg DOMR. Based on this study also known that the best time for spot sampling to determine the total excretion of PD in Bligon was in the range

  16. A sub-boiling distillation method for the preparation of low carbon content water from urine samples for tritium measurement by liquid scintillation counting

    International Nuclear Information System (INIS)

    Nogawa, Norio; Makide, Yoshihiro

    1999-01-01

    A new preparation method was developed for obtaining low carbon content water from urine samples for the measurement of tritium by a liquid scintillation counter. The method uses a simple and convenient subboiling distillation bottle. Many urine samples have been purified by this method and the change of tritium level in a tritium-handling radiation-worker was observed

  17. Liquid chromatographic determination of pioglitazone in pharmaceuticals, serum and urine samples

    International Nuclear Information System (INIS)

    Abro, K.; Memon, N.; Bhanger, M.I.; Mahesar, S.A.; Parveen, S.

    2011-01-01

    A rapid and reliable analytical method based on high-performance liquid chromatography (HPLC) with UV detection (221 nm) has been developed for the determination of the anti-hyper glycemic agent Pioglitazone in pharmaceutical formulations and biological fluids (serum and urine) after clean-up with solid-phase extraction. Chromatographic separation was achieved with a Chromolith Performance RP-18e (10 4.6mm) column using mobile phase composition of acetonitrile: mixed phosphate buffer (pH 2.5; 10mM) (30:70, v/v) with a flow rate of 2.0mL/min. The total run time was 2 min. under optimized conditions. The calibration curve was found to be linear in the range of 1-10 mu g mL/sup -1/ with regression coefficient of 0.9996, and the lower limit of detection 72 ng/20 mu L injection. The method has been validated for the system suitability, linearity, precision and accuracy, limits of detection, specificity, stability and robustness. The %recovery of Pioglitazone in pharmaceutical formulations was found to be 104.7%. The assay has been applied successfully to the pharmaceutical Tablet samples and biological fluids (serum and urine) of healthy volunteers. (author)

  18. Antibiotic use in heavy pigs: Comparison between urine and muscle samples from food chain animals analysed by HPLC-MS/MS.

    Science.gov (United States)

    Chiesa, Luca Maria; Nobile, Maria; Panseri, Sara; Arioli, Francesco

    2017-11-15

    The antibiotic overuse in zoothechnics, due to prophylactic and therapeutic treatments, or to their growth-promoting activity, is a major cause for the onset of widespread antibiotic resistance. Of particular relevance to this study, is the antibiotic abuse in pig breeding. Despite the comprehensive literature on residue controls in pig muscle, data on pig urine, a non-invasive, on-farm collectable matrix, are lacking. Therefore, we validated an HPLC-MS/MS method to detect 29 antimicrobials from eight classes and applied it to 43 anonymous pig urine and muscle paired samples and fulfilled the parameters in agreement with the Commission Decision 2002/657/UE. The analytical limits were moreover much lower than the maximum residue limits (MRLs) required by the Commission Regulation 37/2010/UE. In the samples, antibiotics were usually detected at higher frequencies and concentrations in urine than muscle. Urine proved a useful tool to detect antibiotic administration and their excessive use in pig farming is depicted. Copyright © 2017. Published by Elsevier Ltd.

  19. Monoclonal antibody-based dipstick assay: a reliable field applicable technique for diagnosis of Schistosoma mansoni infection using human serum and urine samples.

    Science.gov (United States)

    Demerdash, Zeinab; Mohamed, Salwa; Hendawy, Mohamed; Rabia, Ibrahim; Attia, Mohy; Shaker, Zeinab; Diab, Tarek M

    2013-02-01

    A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies.

  20. Reassessment of 239Pu on planchets from human urine samples at ultra-trace levels using Aridus-ICP-SFMS and AMS

    International Nuclear Information System (INIS)

    Hernandez-Mendoza, H.; Chamizo, E.; Delgado, A.; Garcia-Leon, M.; Yllera, A.

    2012-01-01

    New analytical methods developed at the facilities here, based on two ultra-sensitive mass spectrometry (MS) techniques, inductively coupled plasma sector field mass spectrometer with a desolvator system (Aridus-ICP-SFMS) and accelerator MS (AMS), have been applied in this work for the reassessment of 239 Pu in alpha spectrometry (AS) planchets corresponding to spiked human urine samples. The obtained 239 Pu minimum detectable activities (MDAs) values by Aridus-ICP-SFMS and AMS were 3 fg (∼6.92 μBq) and 0.4 fg (∼0.92 μBq), respectively, per sample, which are much better than those attainable by AS [50 fg (∼115.3 μBq) of 239 Pu per sample, approximately]. Therefore, it is demonstrated that the MS techniques employed in this work are very powerful tools for internal dosimetry studies in human urine samples, giving excellent results when the reassessment of AS planchets is needed (samples with a Pu concentration below or at the MDA levels measurable by AS). This work is the continuation of an article published in J. Anal. At. Spectrom. 25 (1410-1415) 2010. (authors)

  1. Genotyping for DQA1 and PM loci in urine using PCR-based amplification: effects of sample volume, storage temperature, preservatives, and aging on DNA extraction and typing.

    Science.gov (United States)

    Vu, N T; Chaturvedi, A K; Canfield, D V

    1999-05-31

    Urine is often the sample of choice for drug screening in aviation/general forensic toxicology and in workplace drug testing. In some instances, the origin of the submitted samples may be challenged because of the medicolegal and socioeconomic consequences of a positive drug test. Methods for individualization of biological samples have reached a new boundary with the application of the polymerase chain reaction (PCR) in DNA profiling, but a successful characterization of the urine specimens depends on the quantity and quality of DNA present in the samples. Therefore, the present study investigated the influence of storage conditions, sample volume, concentration modes, extraction procedures, and chemical preservations on the quantity of DNA recovered, as well as the success rate of PCR-based genotyping for DQA1 and PM loci in urine. Urine specimens from male and female volunteers were divided and stored at various temperatures for up to 30 days. The results suggested that sample purification by dialfiltration, using 3000-100,000 molecular weight cut-off filters, did not enhance DNA recovery and typing rate as compared with simple centrifugation procedures. Extraction of urinary DNA by the organic method and by the resin method gave comparable typing results. Larger sample volume yielded a higher amount of DNA, but the typing rates were not affected for sample volumes between 1 and 5 ml. The quantifiable amounts of DNA present were found to be greater in female (14-200 ng/ml) than in male (4-60 ng/ml) samples and decreased with the elapsed time under both room temperature (RT) and frozen storage. Typing of the male samples also demonstrated that RT storage samples produced significantly higher success rates than that of frozen samples, while there was only marginal difference in the DNA typing rates among the conditions tested using female samples. Successful assignment of DQA1 + PM genotype was achieved for all samples of fresh urine, independent of gender

  2. Diagnostic performance of Schistosoma real-time PCR in urine samples from Kenyan children infected with Schistosoma haematobium

    DEFF Research Database (Denmark)

    Vinkeles Melchers, Natalie V. S.; van Dam, Govert J.; Shaproski, David

    2014-01-01

    treatment. METHODOLOGY: Previously collected urine samples (N = 390) from 114 preselected proven parasitological and/or clinical S. haematobium positive Kenyan schoolchildren were analyzed by a Schistosoma internal transcribed spacer-based real-time PCR after 14 years of storage. Pre-treatment day......, respectively. Based on the 'gold standard', PCR showed high sensitivity (>92%) as compared to >31% sensitivity for microscopy, both pre- and post-treatment. CONCLUSIONS/SIGNIFICANCE: Detection and quantification of Schistosoma DNA in urine by real-time PCR was shown to be a powerful and specific diagnostic...

  3. Critical investigation of the separation of noradrenaline and adrenaline from urine samples using Al2O3 as adsorbant

    International Nuclear Information System (INIS)

    Neidhart, B.; Kringe, K.-P.; Deutschmann, P.

    1983-01-01

    A critical investigation of the separation of free noradrenaline and adrenaline from urine samples revealed serious errors during sample pretreatment using Al 2 O 3 as adsorbent. An exact and rapid pH adjustment of the sample, using thymol-blue as indicator, proved to be the chief prerequisite for precise and accurate results. Increasing temperature and pH favour the oxidative decomposition of the catecholamines during routine analysis. This was examined, using the radiotracer method and liquid scintillation counting. (author)

  4. A follow-up urine sample has limited value after treatment for urinary tract infection in children

    DEFF Research Database (Denmark)

    Lytzen, Rebekka; Kaalund-Jørgensen, Kristine; Ahmed, Akhlaq

    2015-01-01

    INTRODUCTION: A routine follow-up urine sample (FUS) in the form of a midstream urine sample (MSU) is recommended after treatment for urinary tract infection (UTI) according to the Danish Paediatric Society (DPS) and "Lægehåndbogen" published by Danish Regions. We studied the effect of FUS...... with a focus on patients without symptoms at the time of FUS. METHODS: Consecutive patients below 16.0 years treated for upper or lower UTI from 1 January 2009 to 31 December 2009 at Hvidovre Hospital in accordance with the guidelines of the department and the DPS. All patients were asked to provide a FUS...... within 21 days. RESULTS: A total of 87 patients were treated for upper UTI: 59 girls and 28 boys, the median age was 1.1 year (range: 0.1-15.6 years); and 42 girls were treated for lower UTI, their median age was 8.2 years (range: 2.5-15.3 years). After treatment, the risk of a UTI was 0% (0/87) after...

  5. Rapid bioassay method for estimation of 90Sr in urine samples by liquid scintillation counting

    International Nuclear Information System (INIS)

    Wankhede, Sonal; Chaudhary, Seema; Sawant, Pramilla D.

    2018-01-01

    Radiostrontium (Sr) is a by-product of the nuclear fission of uranium and plutonium in nuclear reactors and is an important radionuclide in spent nuclear fuel and radioactive waste. Rapid bioassay methods are required for estimating Sr in urine following internal contamination. Decision regarding medical intervention, if any can be based upon the results of urinalysis. The present method used at Bioassay Laboratory, Trombay is by Solid Extraction Chromatography (SEC) technique. The Sr separated from urine sample is precipitated as SrCO 3 and analyzed gravimetrically. However, gravimetric procedure is time consuming and therefore, in the present study, feasibility of Liquid Scintillation Counting for direct detection of radiostrontium in effluent was explored. The results obtained in the present study were compared with those obtained using gravimetric method

  6. Biological Monitoring of Human Exposure to Neonicotinoids Using Urine Samples, and Neonicotinoid Excretion Kinetics.

    Directory of Open Access Journals (Sweden)

    Kouji H Harada

    Full Text Available Neonicotinoids, which are novel pesticides, have entered into usage around the world because they are selectively toxic to arthropods and relatively non-toxic to vertebrates. It has been suggested that several neonicotinoids cause neurodevelopmental toxicity in mammals. The aim was to establish the relationship between oral intake and urinary excretion of neonicotinoids by humans to facilitate biological monitoring, and to estimate dietary neonicotinoid intakes by Japanese adults.Deuterium-labeled neonicotinoid (acetamiprid, clothianidin, dinotefuran, and imidacloprid microdoses were orally ingested by nine healthy adults, and 24 h pooled urine samples were collected for 4 consecutive days after dosing. The excretion kinetics were modeled using one- and two-compartment models, then validated in a non-deuterium-labeled neonicotinoid microdose study involving 12 healthy adults. Increased urinary concentrations of labeled neonicotinoids were observed after dosing. Clothianidin was recovered unchanged within 3 days, and most dinotefuran was recovered unchanged within 1 day. Around 10% of the imidacloprid dose was excreted unchanged. Most of the acetamiprid was metabolized to desmethyl-acetamiprid. Spot urine samples from 373 Japanese adults were analyzed for neonicotinoids, and daily intakes were estimated. The estimated average daily intake of these neonicotinoids was 0.53-3.66 μg/day. The highest intake of any of the neonicotinoids in the study population was 64.5 μg/day for dinotefuran, and this was <1% of the acceptable daily intake.

  7. Heavy metal susceptibility of Escherichia coli isolated from urine samples from Sweden, Germany, and Spain

    OpenAIRE

    Suetterlin, S; Tellez-Castillo, CJ; Anselem, L; Yin, H; Bray, JE; Maiden, MCJ

    2018-01-01

    Antimicrobial resistance is a major health care problem, with the intensive use of heavy metals and biocides recently being identified as potential contributing factors to the aggravation of this situation. This study investigated heavy metal susceptibility and genetic resistance determinants in Escherichia coli isolated from clinical urine samples from Sweden, Germany and Spain. A total of 186 isolates were tested for minimal inhibition concentration to sodium arsenite, silver nitrate and co...

  8. Bioassay techniques for {sup 55}Fe in urine samples

    Energy Technology Data Exchange (ETDEWEB)

    Cregan, S P; Leon, J W; Linauskas, S H

    1993-11-01

    Solvent extraction, ion chromatography and several rapid screening methods were developed and evaluated for {sup 55}Fe bioassay applications. Isopropyl ether and TNOA column extractions had radiochemical recoveries exceeding 90%. These were very reproducible with a coefficient of variation less than 5%. Screening techniques investigated included direct counting of ashed urine solids, and Fe(OH){sub 3}. precipitated from urine. The sensitivities (2-50 Bq/d urine) of the screening methods were usually limited by the effective urine volume that could be counted in a liquid scintillation counter. The reference isopropyl ether and chromatography methods could easily achieve sensitivities well below the 1 Bq/d urine output target. (author). 49 refs., 3 tabs., 5 figs.

  9. Urine storage under refrigeration preserves the sample in chemical, cellularity and bacteriuria analysis of ACS

    OpenAIRE

    Karen Cristina Barcellos Ribeiro; Bruno Rotondo Levenhagem Serabion; Eduardo Lima Nolasco; Chislene Pereira Vanelli; Harleson Lopes de Mesquita; José Otávio do Amaral Corrêa

    2013-01-01

    INTRODUCTION: The analysis of urine abnormal constituents and sediment (ACS) comprises tests of great diagnostic and prognostic value in clinical practice. When the analysis of ACS cannot be performed within two hours after collection, the sample must be preserved in order to avoid pre-analytical interferences. Refrigeration is the most applied technique due to its cost effectiveness. Moreover, it presents fewer inconveniences when compared to chemical preservation. However, changes in ACS ma...

  10. Impact of collection conditions on the metabolite content of human urine samples as analyzed by liquid chromatography coupled to mass spectrometry and nuclear magnetic resonance spectroscopy.

    Science.gov (United States)

    Roux, Aurélie; Thévenot, Etienne A; Seguin, François; Olivier, Marie-Françoise; Junot, Christophe

    There is a lack of comprehensive studies documenting the impact of sample collection conditions on metabolic composition of human urine. To address this issue, two experiments were performed at a 3-month interval, in which midstream urine samples from healthy individuals were collected, pooled, divided into several aliquots and kept under specific conditions (room temperature, 4 °C, with or without preservative) up to 72 h before storage at -80 °C. Samples were analyzed by high-performance liquid chromatography coupled to high-resolution mass spectrometry and bacterial contamination was monitored by turbidimetry. Multivariate analyses showed that urinary metabolic fingerprints were affected by the presence of preservatives and also by storage at room temperature from 24 to 72 h, whereas no change was observed for urine samples stored at 4 °C over a 72-h period. Investigations were then focused on 280 metabolites previously identified in urine: 19 of them were impacted by the kind of sample collection protocol in both experiments, including 12 metabolites affected by bacterial contamination and 7 exhibiting poor chemical stability. Finally, our results emphasize that the use of preservative prevents bacterial overgrowth, but does not avoid metabolite instability in solution, whereas storage at 4 °C inhibits bacterial overgrowth at least over a 72-h period and slows the chemical degradation process. Consequently, and for further LC/MS analyses, human urine samples should be kept at 4 °C if their collection is performed over 24 h.

  11. Biological Monitoring of Human Exposure to Neonicotinoids Using Urine Samples, and Neonicotinoid Excretion Kinetics

    Science.gov (United States)

    Harada, Kouji H.; Tanaka, Keiko; Sakamoto, Hiroko; Imanaka, Mie; Niisoe, Tamon; Hitomi, Toshiaki; Kobayashi, Hatasu; Okuda, Hiroko; Inoue, Sumiko; Kusakawa, Koichi; Oshima, Masayo; Watanabe, Kiyohiko; Yasojima, Makoto; Takasuga, Takumi; Koizumi, Akio

    2016-01-01

    Background Neonicotinoids, which are novel pesticides, have entered into usage around the world because they are selectively toxic to arthropods and relatively non-toxic to vertebrates. It has been suggested that several neonicotinoids cause neurodevelopmental toxicity in mammals. The aim was to establish the relationship between oral intake and urinary excretion of neonicotinoids by humans to facilitate biological monitoring, and to estimate dietary neonicotinoid intakes by Japanese adults. Methodology/Principal Findings Deuterium-labeled neonicotinoid (acetamiprid, clothianidin, dinotefuran, and imidacloprid) microdoses were orally ingested by nine healthy adults, and 24 h pooled urine samples were collected for 4 consecutive days after dosing. The excretion kinetics were modeled using one- and two-compartment models, then validated in a non-deuterium-labeled neonicotinoid microdose study involving 12 healthy adults. Increased urinary concentrations of labeled neonicotinoids were observed after dosing. Clothianidin was recovered unchanged within 3 days, and most dinotefuran was recovered unchanged within 1 day. Around 10% of the imidacloprid dose was excreted unchanged. Most of the acetamiprid was metabolized to desmethyl-acetamiprid. Spot urine samples from 373 Japanese adults were analyzed for neonicotinoids, and daily intakes were estimated. The estimated average daily intake of these neonicotinoids was 0.53–3.66 μg/day. The highest intake of any of the neonicotinoids in the study population was 64.5 μg/day for dinotefuran, and this was <1% of the acceptable daily intake. PMID:26731104

  12. Speciation of arsenic in biological samples.

    Science.gov (United States)

    Mandal, Badal Kumar; Ogra, Yasumitsu; Anzai, Kazunori; Suzuki, Kazuo T

    2004-08-01

    Speciation of arsenicals in biological samples is an essential tool to gain insight into its distribution in tissues and its species-specific toxicity to target organs. Biological samples (urine, hair, fingernail) examined in the present study were collected from 41 people of West Bengal, India, who were drinking arsenic (As)-contaminated water, whereas 25 blood and urine samples were collected from a population who stopped drinking As contaminated water 2 years before the blood collection. Speciation of arsenicals in urine, water-methanol extract of freeze-dried red blood cells (RBCs), trichloroacetic acid treated plasma, and water extract of hair and fingernail was carried out by high-performance liquid chromatography (HPLC)-inductively coupled argon plasma mass spectrometry (ICP MS). Urine contained arsenobetaine (AsB, 1.0%), arsenite (iAs(III), 11.3), arsenate (iAs(V), 10.1), monomethylarsonous acid (MMA(III), 6.6), monomethylarsonic acid (MMA(V), 10.5), dimethylarsinous acid (DMA(III), 13.0), and dimethylarsinic acid (DMA(V), 47.5); fingernail contained iAs(III) (62.4%), iAs(V) (20.2), MMA(V) (5.7), DMA(III) (8.9), and DMA(V) (2.8); hair contained iAs(III) (58.9%), iAs(V) (34.8), MMA(V) (2.9), and DMA(V) (3.4); RBCs contained AsB (22.5%) and DMA(V) (77.5); and blood plasma contained AsB (16.7%), iAs(III) (21.1), MMA(V) (27.1), and DMA(V) (35.1). MMA(III), DMA(III), and iAs(V) were not found in any plasma and RBCs samples, but urine contained all of them. Arsenic in urine, fingernails, and hair are positively correlated with water As, suggesting that any of these measurements could be considered as a biomarker to As exposure. Status of urine and exogenous contamination of hair urgently need speciation of As in these samples, but speciation of As in nail is related to its total As (tAs) concentration. Therefore, total As concentrations of nails could be considered as biomarker to As exposure in the endemic areas.

  13. Speciation of arsenic in biological samples

    International Nuclear Information System (INIS)

    Mandal, Badal Kumar; Ogra, Yasumitsu; Anzai, Kazunori; Suzuki, Kazuo T.

    2004-01-01

    Speciation of arsenicals in biological samples is an essential tool to gain insight into its distribution in tissues and its species-specific toxicity to target organs. Biological samples (urine, hair, fingernail) examined in the present study were collected from 41 people of West Bengal, India, who were drinking arsenic (As)-contaminated water, whereas 25 blood and urine samples were collected from a population who stopped drinking As contaminated water 2 years before the blood collection. Speciation of arsenicals in urine, water-methanol extract of freeze-dried red blood cells (RBCs), trichloroacetic acid treated plasma, and water extract of hair and fingernail was carried out by high-performance liquid chromatography (HPLC)-inductively coupled argon plasma mass spectrometry (ICP MS). Urine contained arsenobetaine (AsB, 1.0%), arsenite (iAs III , 11.3), arsenate (iAs V , 10.1), monomethylarsonous acid (MMA III , 6.6), monomethylarsonic acid (MMA V , 10.5), dimethylarsinous acid (DMA III , 13.0), and dimethylarsinic acid (DMA V , 47.5); fingernail contained iAs III (62.4%), iAs V (20.2), MMA V (5.7), DMA III (8.9), and DMA V (2.8); hair contained iAs III (58.9%), iAs V (34.8), MMA V (2.9), and DMA V (3.4); RBCs contained AsB (22.5%) and DMA V (77.5); and blood plasma contained AsB (16.7%), iAs III (21.1), MMA V (27.1), and DMA V (35.1). MMA III , DMA III , and iAs V were not found in any plasma and RBCs samples, but urine contained all of them. Arsenic in urine, fingernails, and hair are positively correlated with water As, suggesting that any of these measurements could be considered as a biomarker to As exposure. Status of urine and exogenous contamination of hair urgently need speciation of As in these samples, but speciation of As in nail is related to its total As (tAs) concentration. Therefore, total As concentrations of nails could be considered as biomarker to As exposure in the endemic areas

  14. Rapid determination of anti-estrogens by gas chromatography/mass spectrometry in urine: Method validation and application to real samples

    Directory of Open Access Journals (Sweden)

    E. Gerace

    2012-02-01

    Full Text Available A fast screening protocol was developed for the simultaneous determination of nine anti-estrogenic agents (aminoglutethimide, anastrozole, clomiphene, drostanolone, formestane, letrozole, mesterolone, tamoxifen, testolactone plus five of their metabolites in human urine. After an enzymatic hydrolysis, these compounds can be extracted simultaneously from urine with a simple liquid–liquid extraction at alkaline conditions. The analytes were subsequently analyzed by fast-gas chromatography/mass spectrometry (fast-GC/MS after derivatization. The use of a short column, high-flow carrier gas velocity and fast temperature ramping produced an efficient separation of all analytes in about 4 min, allowing a processing rate of 10 samples/h. The present analytical method was validated according to UNI EN ISO/IEC 17025 guidelines for qualitative methods. The range of investigated parameters included the limit of detection, selectivity, linearity, repeatability, robustness and extraction efficiency. High MS-sampling rate, using a benchtop quadrupole mass analyzer, resulted in accurate peak shape definition under both scan and selected ion monitoring modes, and high sensitivity in the latter mode. Therefore, the performances of the method are comparable to the ones obtainable from traditional GC/MS analysis. The method was successfully tested on real samples arising from clinical treatments of hospitalized patients and could profitably be used for clinical studies on anti-estrogenic drug administration. Keywords: Anti-estrogens, Fast-GC/MS, Urine screening, Validation, Breast cancer

  15. Impact of collection conditions on the metabolite content of human urine samples as analyzed by liquid chromatography coupled to mass spectrometry and nuclear magnetic resonance spectroscopy

    OpenAIRE

    Roux, Aurélie; Thévenot, Etienne A.; Seguin, François; Olivier, Marie-Françoise; Junot, Christophe

    2014-01-01

    There is a lack of comprehensive studies documenting the impact of sample collection conditions on metabolic composition of human urine. To address this issue, two experiments were performed at a 3-month interval, in which midstream urine samples from healthy individuals were collected, pooled, divided into several aliquots and kept under specific conditions (room temperature, 4 °C, with or without preservative) up to 72 h before storage at −80 °C. Samples were analyzed by high-performance li...

  16. 5C.07: A METHOD TO ESTIMATE 24-HOUR SODIUM EXCRETION THROUGH SPOT URINE SAMPLES AND ITS APPLICATION VALUE FOR TARGET-ORGAN DAMAGE ASSESSMENT.

    Science.gov (United States)

    Wang, H; Zhao, L; Xi, Y; Sun, N

    2015-06-01

    24-h urine sodium excretion is considered the most reliable method to evaluate the salt intakes. However, this method is cumbersome. So we want to develop formulas to estimate 24-h urinary sodium excretion using spot urinary samples in Chinese hypertensive population and explore the application value of this method in salt intake assessment and target organ damage. 1. We enrolled 510 cases of hospitalized patients with hypertension, 2/3 of them were arranged randomly to formula group to develop a new formula and the remainings were used to test the performance of the formula. All participants were instructed to collect a 24-h urine sample, a second morning voiding urine sample (SMU), and a post-meridiem urine sample in the late afternoon or early evening, prior to the evening meal (PMU). All samples were sent to measure sodium and creatinine concentration.2. We compared the differences of office blood pressure, 24-hour ambulatory blood pressure and left ventricular hypertrophy, vascular stiffness and urine protein among groups of different sodium intake. 24hour sodium excretion formulas was obtained using SMU and PMU respectively, which have good cosistency. The difference between the estimated and measured values in sodium excretion is 12.66mmol/day (SMU) and 9.41mmol/day (PM), to be equal to 0.7 g (SMU) and 0.6 g (PM) salt intake. Comparing with Kawasaki and Tanaka method, the new formula shows the lower degree of deviation, and higher accuracy and precision. Blood pressure of high urinary sodium group is higher than that in low urinary sodium group (P < 0.05). Left ventricular hypertrophy and urinary albumin/creatinine aggravated with the salt intake increase, this has eliminated the influence of other factors. All of morphologies of the relationship between ambulatory arterial stiffness index, pulse wave velocity and carotid intima-media thickness with quartiles of sodium intake resembled a J-shaped curve. In Chinese hypertensive population, the

  17. Characterizing concentrations of diethylene glycol and suspected metabolites in human serum, urine, and cerebrospinal fluid samples from the Panama DEG mass poisoning.

    Science.gov (United States)

    Schier, J G; Hunt, D R; Perala, A; McMartin, K E; Bartels, M J; Lewis, L S; McGeehin, M A; Flanders, W D

    2013-12-01

    Diethylene glycol (DEG) mass poisoning is a persistent public health problem. Unfortunately, there are no human biological data on DEG and its suspected metabolites in poisoning. If present and associated with poisoning, the evidence for use of traditional therapies such as fomepizole and/or hemodialysis would be much stronger. To characterize DEG and its metabolites in stored serum, urine, and cerebrospinal fluid (CSF) specimens obtained from human DEG poisoning victims enrolled in a 2006 case-control study. In the 2006 study, biological samples from persons enrolled in a case-control study (42 cases with new-onset, unexplained AKI and 140 age-, sex-, and admission date-matched controls without AKI) were collected and shipped to the Centers for Disease Control and Prevention (CDC) in Atlanta for various analyses and were then frozen in storage. For this study, when sufficient volume of the original specimen remained, the following analytes were quantitatively measured in serum, urine, and CSF: DEG, 2-hydroxyethoxyacetic acid (HEAA), diglycolic acid, ethylene glycol, glycolic acid, and oxalic acid. Analytes were measured using low resolution GC/MS, descriptive statistics calculated and case results compared with controls when appropriate. Specimens were de-identified so previously collected demographic, exposure, and health data were not available. The Wilcoxon Rank Sum test (with exact p-values) and bivariable exact logistic regression were used in SAS v9.2 for data analysis. The following samples were analyzed: serum, 20 case, and 20 controls; urine, 11 case and 22 controls; and CSF, 11 samples from 10 cases and no controls. Diglycolic acid was detected in all case serum samples (median, 40.7 mcg/mL; range, 22.6-75.2) and no controls, and in all case urine samples (median, 28.7 mcg/mL; range, 14-118.4) and only five (23%) controls (median, urine diglycolic acid (both OR > 999; exact p sample results were excluded and two from the same case were averaged, yielding

  18. The UK Biobank sample handling and storage protocol for the collection, processing and archiving of human blood and urine.

    Science.gov (United States)

    Elliott, Paul; Peakman, Tim C

    2008-04-01

    UK Biobank is a large prospective study in the UK to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. Extensive data and biological samples are being collected from 500,000 participants aged between 40 and 69 years. The biological samples that are collected and how they are processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. The aim of the UK Biobank sample handling and storage protocol is to specify methods for the collection and storage of participant samples that give maximum scientific return within the available budget. Processing or storage methods that, as far as can be predicted, will preclude current or future assays have been avoided. The protocol was developed through a review of the literature on sample handling and processing, wide consultation within the academic community and peer review. Protocol development addressed which samples should be collected, how and when they should be processed and how the processed samples should be stored to ensure their long-term integrity. The recommended protocol was extensively tested in a series of validation studies. UK Biobank collects about 45 ml blood and 9 ml of urine with minimal local processing from each participant using the vacutainer system. A variety of preservatives, anti-coagulants and clot accelerators is used appropriate to the expected end use of the samples. Collection of other material (hair, nails, saliva and faeces) was also considered but rejected for the full cohort. Blood and urine samples from participants are transported overnight by commercial courier to a central laboratory where they are processed and aliquots of urine, plasma, serum, white cells and red cells stored in ultra-low temperature archives. Aliquots of whole blood are also stored for potential future production of immortalized cell lines. A standard panel of haematology assays is

  19. N-acetyl-4-aminophenol (paracetamol) in urine samples of 6-11-year-old Danish school children and their mothers

    DEFF Research Database (Denmark)

    Nielsen, J. K.; Modick, H.; Morck, T. A.

    2015-01-01

    Recent studies indicate an association between the use of paracetamol during pregnancy and reproductive disorders in male offspring. Furthermore, N-acetyl-4-aminophenol (NAAP, paracetamol) has been shown to be ubiquitously excreted in urine samples of the general population. To investigate the in...... the internal body burden of the Danish population to NAAP for the first time, 288 morning urine samples from 6- to 11-year-old Danish school children and their mothers were analyzed for NAAP. NAAP was measurable in all mothers and all of the children except for one child. Results showed...... lifestyle related exposure (e.g. via food or indoor air sources). However, we did not detect any association between lifestyle data from questionnaires and levels of NAAP excretion in this study. The knowledge about possible sources of exposure leading to this omnipresent paracetamol excretion is limited...

  20. Determination of plutonium in urine samples from 24 h by ICP-W.f.'s and AMS

    International Nuclear Information System (INIS)

    Aragon del Valle, A.; Anton Mateos, M. P.; Chamizo Calvo, E.; Barrado Olmedo, A. I.; Yllera de Llano, A.

    2013-01-01

    The identification and quantification of alpha emitters in biological samples is essential to estimate the internal dose received by workers exposed. The object of this research is to assess the suitability of AMS and ICP-WSFS as measure alternative techniques to the EA of high resolution in the quantification of plutonium in urine 24h. (Author)

  1. Profiling a multiplex short tandem repeat loci from human urine with use of low cost on-site technology for verification of sample authenticity.

    Science.gov (United States)

    Pires, Nuno M M; Tao Dong; Berntzen, Lasse; Lonningdal, Torill

    2017-07-01

    This work focuses on the development of a sophisticated technique via STR typing to unequivocally verify the authenticity of urine samples before sent to laboratories. STR profiling was conducted with the CSF1PO, TPOX, TH01 Multiplex System coupled with a smartphone-based detection method. The promising capability of the method to identify distinct STR profiles from urine of different persons opens the possibility to conduct sample authenticity tests. On-site STR profiling could be realized with a self-contained autonomous device with an integrated PCR microchip shown hereby.

  2. Use of fission track analysis technique for the determination of MicroBequerel level of {sup 239}Pu in urine samples from radiation workers handling MOX fuel

    Energy Technology Data Exchange (ETDEWEB)

    Yadav, J.R., E-mail: yadav_jogendra@rediffmail.co [Health Physics Laboratory, Health Physics Division, BARC, Tarapur 401502 (India); Rao, D.D.; Kumar, Ranjeet [Health Physics Laboratory, Health Physics Division, BARC, Tarapur 401502 (India); Aggarwal, S.K. [Fuel chemistry Division, BARC, Trombay, Mumbai 400085 (India)

    2011-07-15

    Fission track analysis (FTA) technique for the determination of {sup 239}Pu excreted through urine has been standardized using blank samples, tracer and {sup 239}Pu spikes. Double stage anion exchange separation protocol has been applied and an average radiochemical recovery of {sup 239}Pu of 18% was obtained. An average track registration efficiency of 11 tracks per {mu}Bq of {sup 239}Pu, irradiated to 0.35x10{sup 17} neutron fluence was established. Reagent blank urine samples from 11 controlled subjects were analyzed by FTA and an average of 149{+-}14 tracks was obtained. Minimum detectable activity of 34 {mu}Bq L{sup -1} of urine sample was obtained and will be useful for monitoring chronic exposure cases handling MOX fuel.

  3. Evaluation of First Voided Urine Samples For Detection of Ureaplasma Uriealyticum and Mycoplasma Hominis in Urinary Tracts of Men and Women Suffering from Nongonococcal and Nonspecific Urethritis

    Directory of Open Access Journals (Sweden)

    M Mohamadi

    2007-07-01

    Full Text Available Introduction: Ureaplasma uriealyticum is one of the most important causes of Nongonococcal and Nonspecific urethritis (NGU & NSU in men. Mycoplasma hominis too has a causal role in NGU & NSU. This study aimed to investigate whether it is possible to detect Mycoplasma hominis and Ureaplasma uriealyticum in first voided urine samples in men suffering from NGU & NSU without complaints of urethral secretions and in women with clinical symptoms despite negative vaginal secretion culture test results. Methods: First voided urine samples were taken from 150 patients (21 women & 129 men suffering from NGU & NSU who referred to the Division of Bacteriology, School of Public Health, Tehran University of Medical Sciences in 2004-2005. Samples were examined by culture method. Results: Cultures were positive for Mycoplasma and Ureoplasma in 49 (32.6 % of the 150 samples. Of the 21 samples taken from women, 5 samples were positive for Mycoplasma & Ureoplasma (2 samples Mycoplasma, 3 samples Ureaplasma. Samples from 44 men were positive for Ureoplasma & Mycoplasma(17 samples Mycoplasma, 4 samples Ureaplasma and 23 samples were positive for both. Ureoplasma urealyticum was detected in 30 samples (20% and Mycoplasma hominis, was detected in 42 samples (28%. Conclusion: The results of this study provides evidence that culture tests can be done using voided urine in order to detect Mycoplasma hominis and ureaplasma urealyticum in patients suffering from Nongonococcal urethris; men who do not have urethral secretions and women with clinical symptoms despite negative vaginal secretion culture test results.

  4. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF URINE SAMPLES FOR METAL, PESTICIDE, AND CREATININE ANALYSIS (F10)

    Science.gov (United States)

    The purpose of this SOP is to describe the procedures for collection, storage, and shipment of urine samples for metal, pesticides, and creatinine analysis. Samples were collected on Days 2 and 8 of each Cycle. The Day 2 sample was analyzed for metals and creatinine. The Day 8...

  5. Study on the abnormal expression of carbohydrate antigen 19-9 in the urine samples of the patients with bladder cancer

    International Nuclear Information System (INIS)

    Lu Yun; Yuan Kun; Deng Shouzhen; Lin Xiangtong; Zhang Yuanfang

    2002-01-01

    To investigate the levels of carbohydrate antigen 19-9 in the urine samples of the patients with bladder cancer and to evaluate its clinical diagnostic value. Urine samples were taken from 30 patients with bladder cancer, 53 with benign, 22 with malignant urological diseases and 35 with malignant tumors from other systems, together with 30 normal subjects which have no any history of cancers or other urological diseases. CA19-9 was assayed by Chiron Diagnostic Corporation ACS: 180SE. The CA19-9 level of the group with bladder cancer was 159.0 +- 128.0 U/mL, while that of the group of control was 12.4 +- 8.4 U/mL. The critical points were determined as the mean value of the group of control +-1.96SD, then >28.9U/mL was considered as positive. The diagnostic sensitivity for bladder TCC were 86.7% and specificity were 68.2%. CA19-9 level in the bladder cancer group was significantly different from that of control group (P<0.001), and also different from those of other groups. The urine CA19-9 level in the group of benign urological diseases was 53.9+-77.9%, significantly higher than that of control (P=0.001), but not significantly different from those of the group of other urological cancers and other systems cancers. Preliminary study indicates that CA19-9 urine samples study is a non-invasive auxiliary index for the clinical diagnosis of bladder cancer. The method is simple and useful. But the interference fro mother benign and malignant diseases as well as gene-types should be considered in clinical practice

  6. Validation of a high performance liquid chromatography analysis for the determination of noradrenaline and adrenaline in human urine with an on-line sample purification

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Kristiansen, J; Nielsen, J L

    1999-01-01

    A high performance liquid chromatography (HPLC) method with fluorescence detection including an on-line purification was established for determination of catecholamines in human urine. The method was evaluated using samples of pooled urine spiked with catecholamines and validated for measurements...

  7. An analysis of workers' tritium concentration in urine samples as a function of time after intake at Korean pressurised heavy water reactors.

    Science.gov (United States)

    Kim, Hee Geun; Kong, Tae Young

    2012-12-01

    In general, internal exposure from tritium at pressurised heavy water reactors (PHWRs) accounts for ∼20-40 % of the total radiation dose. Tritium usually reaches the equilibrium concentration after a few hours inside the body and is then excreted from the body with an effective half-life in the order of 10 d. In this study, tritium metabolism was reviewed using its excretion rate in urine samples of workers at Korean PHWRs. The tritium concentration in workers' urine samples was also measured as a function of time after intake. On the basis of the monitoring results, changes in the tritium concentration inside the body were then analysed.

  8. Fluorimetric routine determination of uranium in urine samples

    International Nuclear Information System (INIS)

    Widua, L.; Schieferdecker, H.; Hezel, U.

    With a modified RA 2 reflectance accessory for the Zeiss PMQII/PMQ3 spectrophotometer, uranium in urine was detected with higher sensitivity. A quick method is now available with a detection limit of <2 μg U/1 urine for the determination of possible uranium incorporations, whose sensitivity meets the requirements of radiation protection. Compared with other extraction methods, the instrument outlay and the required working time are small. The total error of the method is below 5 percent

  9. Determination of total concentration of chemically labeled metabolites as a means of metabolome sample normalization and sample loading optimization in mass spectrometry-based metabolomics.

    Science.gov (United States)

    Wu, Yiman; Li, Liang

    2012-12-18

    For mass spectrometry (MS)-based metabolomics, it is important to use the same amount of starting materials from each sample to compare the metabolome changes in two or more comparative samples. Unfortunately, for biological samples, the total amount or concentration of metabolites is difficult to determine. In this work, we report a general approach of determining the total concentration of metabolites based on the use of chemical labeling to attach a UV absorbent to the metabolites to be analyzed, followed by rapid step-gradient liquid chromatography (LC) UV detection of the labeled metabolites. It is shown that quantification of the total labeled analytes in a biological sample facilitates the preparation of an appropriate amount of starting materials for MS analysis as well as the optimization of the sample loading amount to a mass spectrometer for achieving optimal detectability. As an example, dansylation chemistry was used to label the amine- and phenol-containing metabolites in human urine samples. LC-UV quantification of the labeled metabolites could be optimally performed at the detection wavelength of 338 nm. A calibration curve established from the analysis of a mixture of 17 labeled amino acid standards was found to have the same slope as that from the analysis of the labeled urinary metabolites, suggesting that the labeled amino acid standard calibration curve could be used to determine the total concentration of the labeled urinary metabolites. A workflow incorporating this LC-UV metabolite quantification strategy was then developed in which all individual urine samples were first labeled with (12)C-dansylation and the concentration of each sample was determined by LC-UV. The volumes of urine samples taken for producing the pooled urine standard were adjusted to ensure an equal amount of labeled urine metabolites from each sample was used for the pooling. The pooled urine standard was then labeled with (13)C-dansylation. Equal amounts of the (12)C

  10. Validation of a method to quantify chromium, cadmium, manganese, nickel and lead in human whole blood, urine, saliva and hair samples by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Olmedo, P.; Pla, A.; Hernandez, A.F.; Lopez-Guarnido, O.; Rodrigo, L. [Department of Legal Medicine and Toxicology, University of Granada, School of Medicine (Spain); Gil, F., E-mail: fgil@ugr.es [Department of Legal Medicine and Toxicology, University of Granada, School of Medicine (Spain)

    2010-02-05

    For biological monitoring of heavy metal exposure in occupational toxicology, usually whole blood and urine samples are the most widely used and accepted matrix to assess internal xenobiotic exposure. Hair samples and saliva are also of interest in occupational and environmental health surveys but procedures for the determination of metals in saliva and hair are very scarce and to our knowledge there is no validation of a method to quantify Cr, Cd, Mn, Ni and Pb in four different human biological materials (whole blood, urine, saliva and axilary hair) by electrothermal atomization atomic absorption spectrometry (ETAAS). In the present study, quantification methods for the determination of Cr, Cd, Mn, Ni and Pb in whole blood, urine, saliva and axilary hair were validated according to the EU common standards. Pyrolisis and atomization temperatures have been determined. The main parameters evaluated were: detection and quantification limits, linearity range, repeatability, reproducibility, recovery and uncertainty. Accuracy of the methods was tested with the whole blood, urine and hair certified reference materials and recoveries of the spiked samples were acceptable ranged from 96.3 to 107.8%.

  11. Validation of a method to quantify chromium, cadmium, manganese, nickel and lead in human whole blood, urine, saliva and hair samples by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Olmedo, P.; Pla, A.; Hernandez, A.F.; Lopez-Guarnido, O.; Rodrigo, L.; Gil, F.

    2010-01-01

    For biological monitoring of heavy metal exposure in occupational toxicology, usually whole blood and urine samples are the most widely used and accepted matrix to assess internal xenobiotic exposure. Hair samples and saliva are also of interest in occupational and environmental health surveys but procedures for the determination of metals in saliva and hair are very scarce and to our knowledge there is no validation of a method to quantify Cr, Cd, Mn, Ni and Pb in four different human biological materials (whole blood, urine, saliva and axilary hair) by electrothermal atomization atomic absorption spectrometry (ETAAS). In the present study, quantification methods for the determination of Cr, Cd, Mn, Ni and Pb in whole blood, urine, saliva and axilary hair were validated according to the EU common standards. Pyrolisis and atomization temperatures have been determined. The main parameters evaluated were: detection and quantification limits, linearity range, repeatability, reproducibility, recovery and uncertainty. Accuracy of the methods was tested with the whole blood, urine and hair certified reference materials and recoveries of the spiked samples were acceptable ranged from 96.3 to 107.8%.

  12. Carbon coated magnetic nanoparticles as a novel magnetic solid phase extraction adsorbent for simultaneous extraction of methamphetamine and ephedrine from urine samples.

    Science.gov (United States)

    Taghvimi, Arezou; Hamishehkar, Hamed

    2017-01-15

    This paper develops a highly selective, specific and efficient method for simultaneous determination of ephedrine and methamphetamine by a new carbon coated magnetic nanoparticles (C/MNPs) as a magnetic solid phase extraction (MSPE) adsorbent in biological urine medium. The characterization of synthesized magnetic nano adsorbent was completely carried out by various characterization techniques like Fourier transform infrared (FT-IR) spectroscopy, powder x-ray diffraction (XRD), scanning electron microscopy (SEM) and vibrating sample magnetometer (VSM). Nine important parameters influencing extraction efficiency including amount of adsorbent, amounts of sample volume, pH, type and amount of extraction organic solvent, time of extraction and desorption, agitation rate and ionic strength of extraction medium, were studied and optimized. Under optimized extraction conditions, a good linearity was observed in the concentration range of 100-2000ng/mL for ephedrine and 100-2500ng/mL for methamphetamine. Analysis of positive urine samples was carried out by proposed method with the recovery of 98.71 and 97.87% for ephedrine and methamphetamine, respectively. The results indicated that carbon coated magnetic nanoparticles could be applied in clinical and forensic laboratories for simultaneous determination of abused drugs in urine media. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration

    Science.gov (United States)

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    Background The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. Methods During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Results Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples

  14. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration.

    Science.gov (United States)

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. The UPCR in samples with low

  15. Rapid determination of anti-estrogens by gas chromatography/mass spectrometry in urine: Method validation and application to real samples.

    Science.gov (United States)

    Gerace, E; Salomone, A; Abbadessa, G; Racca, S; Vincenti, M

    2012-02-01

    A fast screening protocol was developed for the simultaneous determination of nine anti-estrogenic agents (aminoglutethimide, anastrozole, clomiphene, drostanolone, formestane, letrozole, mesterolone, tamoxifen, testolactone) plus five of their metabolites in human urine. After an enzymatic hydrolysis, these compounds can be extracted simultaneously from urine with a simple liquid-liquid extraction at alkaline conditions. The analytes were subsequently analyzed by fast-gas chromatography/mass spectrometry (fast-GC/MS) after derivatization. The use of a short column, high-flow carrier gas velocity and fast temperature ramping produced an efficient separation of all analytes in about 4 min, allowing a processing rate of 10 samples/h. The present analytical method was validated according to UNI EN ISO/IEC 17025 guidelines for qualitative methods. The range of investigated parameters included the limit of detection, selectivity, linearity, repeatability, robustness and extraction efficiency. High MS-sampling rate, using a benchtop quadrupole mass analyzer, resulted in accurate peak shape definition under both scan and selected ion monitoring modes, and high sensitivity in the latter mode. Therefore, the performances of the method are comparable to the ones obtainable from traditional GC/MS analysis. The method was successfully tested on real samples arising from clinical treatments of hospitalized patients and could profitably be used for clinical studies on anti-estrogenic drug administration.

  16. First intercomparison exercise for Argentine organized by the ARN for the determination of uranium in water and urine samples

    International Nuclear Information System (INIS)

    Serdeiro, Nelida H.; Equillor, Hugo E.

    2004-01-01

    An exercise of intercomparison organized by the Nuclear Regulatory Authority was carried out during the year 2000 for the determination of uranium in samples of water and urine. The exercise was designed to compare the values of uranium obtained by the different laboratories for the same sample, and to promote the identification of the uncertainties linked with the process of obtaining the results. Six laboratories that usually do this type of analysis participated in the exercise. The values informed by the laboratories are presented, as well as an evaluation of the performance of each laboratory

  17. Comparative Study of Seven Commercial Kits for Human DNA Extraction from Urine Samples Suitable for DNA Biomarker-Based Public Health Studies

    Science.gov (United States)

    El Bali, Latifa; Diman, Aurélie; Bernard, Alfred; Roosens, Nancy H. C.; De Keersmaecker, Sigrid C. J.

    2014-01-01

    Human genomic DNA extracted from urine could be an interesting tool for large-scale public health studies involving characterization of genetic variations or DNA biomarkers as a result of the simple and noninvasive collection method. These studies, involving many samples, require a rapid, easy, and standardized extraction protocol. Moreover, for practicability, there is a necessity to collect urine at a moment different from the first void and to store it appropriately until analysis. The present study compared seven commercial kits to select the most appropriate urinary human DNA extraction procedure for epidemiological studies. DNA yield has been determined using different quantification methods: two classical, i.e., NanoDrop and PicoGreen, and two species-specific real-time quantitative (q)PCR assays, as DNA extracted from urine contains, besides human, microbial DNA also, which largely contributes to the total DNA yield. In addition, the kits giving a good yield were also tested for the presence of PCR inhibitors. Further comparisons were performed regarding the sampling time and the storage conditions. Finally, as a proof-of-concept, an important gene related to smoking has been genotyped using the developed tools. We could select one well-performing kit for the human DNA extraction from urine suitable for molecular diagnostic real-time qPCR-based assays targeting genetic variations, applicable to large-scale studies. In addition, successful genotyping was possible using DNA extracted from urine stored at −20°C for several months, and an acceptable yield could also be obtained from urine collected at different moments during the day, which is particularly important for public health studies. PMID:25365790

  18. Comparative study of seven commercial kits for human DNA extraction from urine samples suitable for DNA biomarker-based public health studies.

    Science.gov (United States)

    El Bali, Latifa; Diman, Aurélie; Bernard, Alfred; Roosens, Nancy H C; De Keersmaecker, Sigrid C J

    2014-12-01

    Human genomic DNA extracted from urine could be an interesting tool for large-scale public health studies involving characterization of genetic variations or DNA biomarkers as a result of the simple and noninvasive collection method. These studies, involving many samples, require a rapid, easy, and standardized extraction protocol. Moreover, for practicability, there is a necessity to collect urine at a moment different from the first void and to store it appropriately until analysis. The present study compared seven commercial kits to select the most appropriate urinary human DNA extraction procedure for epidemiological studies. DNA yield has been determined using different quantification methods: two classical, i.e., NanoDrop and PicoGreen, and two species-specific real-time quantitative (q)PCR assays, as DNA extracted from urine contains, besides human, microbial DNA also, which largely contributes to the total DNA yield. In addition, the kits giving a good yield were also tested for the presence of PCR inhibitors. Further comparisons were performed regarding the sampling time and the storage conditions. Finally, as a proof-of-concept, an important gene related to smoking has been genotyped using the developed tools. We could select one well-performing kit for the human DNA extraction from urine suitable for molecular diagnostic real-time qPCR-based assays targeting genetic variations, applicable to large-scale studies. In addition, successful genotyping was possible using DNA extracted from urine stored at -20°C for several months, and an acceptable yield could also be obtained from urine collected at different moments during the day, which is particularly important for public health studies.

  19. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE AND SHIPMENT OF URINE SAMPLES FOR SELECTED METALS AND PESTICIDES (UA-F-20.1)

    Science.gov (United States)

    The purpose of this SOP is to guide the collection, storage, and shipment of urine samples collected for the NHEXAS Arizona project. This SOP provides a brief description of sample, collection, preservation, storage, shipping, and custody procedures. This procedure was followed ...

  20. Molecularly imprinted polymer microspheres prepared by Pickering emulsion polymerization for selective solid-phase extraction of eight bisphenols from human urine samples

    International Nuclear Information System (INIS)

    Yang, Jiajia; Li, Yun; Wang, Jincheng; Sun, Xiaoli; Cao, Rong; Sun, Hao; Huang, Chaonan; Chen, Jiping

    2015-01-01

    Highlights: • BPA imprinted polymer microspheres were prepared by Pickering emulsion polymerization. • Regular spherical shape and narrow diameter distribution. • Good specific adsorption capacity for BPA. • Good class-selectivity and clean-up efficiency for bisphenols in human urine under SPE mode. • Good recoveries and sensitivity for bisphenols using the MIPMS-SPE coupled with HPLC-DAD method. - Abstract: The bisphenol A (BPA) imprinted polymer microspheres were prepared by simple Pickering emulsion polymerization. Compared to traditional bulk polymerization, both high yields of polymer and good control of particle sizes were achieved. The characterization results of scanning electron microscopy and nitrogen adsorption–desorption measurements showed that the obtained molecularly imprinted polymer microsphere (MIPMS) particles possessed regular spherical shape, narrow diameter distribution (30–60 μm), a specific surface area (S BET ) of 281.26 m 2 g −1 and a total pore volume (V t ) of 0.459 cm 3 g −1 . Good specific adsorption capacity for BPA was obtained in the sorption experiment and good class selectivity for BPA and its seven structural analogs (bisphenol F, bisphenol B, bisphenol E, bisphenol AF, bisphenol S, bisphenol AP and bisphenol Z) was demonstrated by the chromatographic evaluation experiment. The MIPMS as solid-phase extraction (SPE) packing material was then evaluated for extraction and clean-up of these bisphenols (BPs) from human urine samples. An accurate and sensitive analytical method based on the MIPMS-SPE coupled with HPLC-DAD has been successfully established for simultaneous determination of eight BPs from human urine samples with detection limits of 1.2–2.2 ng mL −1 . The recoveries of BPs for urine samples at two spiking levels (100 and 500 ng mL −1 for each BP) were in the range of 81.3–106.7% with RSD values below 8.3%

  1. Multiple stage MS in analysis of plasma, serum, urine and in vitro samples relevant to clinical and forensic toxicology.

    Science.gov (United States)

    Meyer, Golo M; Maurer, Hans H; Meyer, Markus R

    2016-01-01

    This paper reviews MS approaches applied to metabolism studies, structure elucidation and qualitative or quantitative screening of drugs (of abuse) and/or their metabolites. Applications in clinical and forensic toxicology were included using blood plasma or serum, urine, in vitro samples, liquids, solids or plant material. Techniques covered are liquid chromatography coupled to low-resolution and high-resolution multiple stage mass analyzers. Only PubMed listed studies published in English between January 2008 and January 2015 were considered. Approaches are discussed focusing on sample preparation and mass spectral settings. Comments on advantages and limitations of these techniques complete the review.

  2. Method validation to measure Strontium-90 in urine sample for internal dosimetry assessment

    International Nuclear Information System (INIS)

    Bitar, A.; Maghrabi, M.; Alhamwi, A.

    2010-12-01

    Occupational individuals exposed at some scientific centers in Syrian Arab Republic to potentially significant intake by ingestion or inhalation during process of producing radiopharmaceutical compounds. The received radioactive intake differs in relation to the amount of radionuclides released during the preparation processes, to the work conditions and to the applying ways of the radiation protection procedures. TLD (Thermoluminescence Dosimeter) is usually used for external radiation monitoring for workers in radioisotope centers. During the external monitoring programme, it was noticed that some workers were exposed to high external dose resultant from radiation accident in their laboratory when preparing Y-90 from Sr-90. For internal dose assessment, chemical method to measure the amount of Sr-90 in urine samples was validated and explained in details in this study. Urine bioassays were carried out and the activities of 90 Sr were determined using liquid scintillation counter. Then, the validated method was used for internal occupational monitoring purposes through the design of internal monitoring programme. The programme was established for four workers who are dealing, twice per month, with an amount of about 20 mCi in each time. At the beginning, theoretical study was done to assess maximum risks for workers. Calculated internal doses showed that it is necessary to apply internal routine monitoring programme for those workers. (author)

  3. Molecularly imprinted polymer microspheres prepared by Pickering emulsion polymerization for selective solid-phase extraction of eight bisphenols from human urine samples.

    Science.gov (United States)

    Yang, Jiajia; Li, Yun; Wang, Jincheng; Sun, Xiaoli; Cao, Rong; Sun, Hao; Huang, Chaonan; Chen, Jiping

    2015-05-04

    The bisphenol A (BPA) imprinted polymer microspheres were prepared by simple Pickering emulsion polymerization. Compared to traditional bulk polymerization, both high yields of polymer and good control of particle sizes were achieved. The characterization results of scanning electron microscopy and nitrogen adsorption-desorption measurements showed that the obtained molecularly imprinted polymer microsphere (MIPMS) particles possessed regular spherical shape, narrow diameter distribution (30-60 μm), a specific surface area (S(BET)) of 281.26 m(2) g(-1) and a total pore volume (V(t)) of 0.459 cm(3) g(-1). Good specific adsorption capacity for BPA was obtained in the sorption experiment and good class selectivity for BPA and its seven structural analogs (bisphenol F, bisphenol B, bisphenol E, bisphenol AF, bisphenol S, bisphenol AP and bisphenol Z) was demonstrated by the chromatographic evaluation experiment. The MIPMS as solid-phase extraction (SPE) packing material was then evaluated for extraction and clean-up of these bisphenols (BPs) from human urine samples. An accurate and sensitive analytical method based on the MIPMS-SPE coupled with HPLC-DAD has been successfully established for simultaneous determination of eight BPs from human urine samples with detection limits of 1.2-2.2 ng mL(-1). The recoveries of BPs for urine samples at two spiking levels (100 and 500 ng mL(-1) for each BP) were in the range of 81.3-106.7% with RSD values below 8.3%. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Preparation of stir cake sorptive extraction based on poly(4-vinylbenzoic acid-divinylbenzene) monolith and its application in sensitive determination of β-agonists in milk and swine urine samples

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Xiaojia, E-mail: hxj@xmu.edu.cn; Chen, Linli; Yuan, Dongxing

    2013-11-15

    Highlights: • A new poly(4-vinylbenzoic acid-divinylbenzene) monolith was first prepared. • The porous monolith was used as sorbent of stir cake sorptive extraction. • The new sorbent could extract β-agonists effectively by multiple interactions. • Method of determination of trace β-agonists in milk and urine samples was developed. -- Abstract: In this study, a new stir cake sorptive extraction (SCSE) based on poly(4-vinylbenzoic acid-divinylbenzene) (VBADB) monolith was prepared. The effect of preparation conditions of monolith on extraction efficiencies was investigated in detail. Several characteristic techniques, such as elemental analysis, infrared spectroscopy, mercury intrusion porosimetry and scanning electron microscopy were used to characterize the monolithic material. The combination of SCSE-VBADB with high-performance liquid chromatography tandem mass spectrometry (HPLC/MS/MS) detection was developed for sensitive determination of ultra-trace β-agonists in milk and swine urine samples. In order to obtain the optimal extraction conditions of SCSE-VBADB for β-agonists, several extractive parameters, including pH values and ionic strength in sample matrix, extraction and desorption time were optimized. Under the optimum conditions, the limits of detection (S/N = 3) for the target analytes were 0.007–0.030 μg/L in milk and 0.002–0.011 μg/L in swine urine, respectively. Excellent method reproducibility was achieved in terms of intraday and interday precisions, indicated by the RSDs of both <10.0%, respectively. Finally, the proposed method was successfully used to detect β-agonists in different milk and swine urines samples. Acceptable recoveries ranged from 50.3% to 113% and 50.1% to 92.2% for milk and swine urine samples, respectively; and the RSDs for reproducibility were less than 8.0% for target analytes in all real samples.

  5. Dual-cloud point extraction coupled to high performance liquid chromatography for simultaneous determination of trace sulfonamide antimicrobials in urine and water samples.

    Science.gov (United States)

    Nong, Chunyan; Niu, Zongliang; Li, Pengyao; Wang, Chunping; Li, Wanyu; Wen, Yingying

    2017-04-15

    Dual-cloud point extraction (dCPE) was successfully developed for simultaneous extraction of trace sulfonamides (SAs) including sulfamerazine (SMZ), sulfadoxin (SDX), sulfathiazole (STZ) in urine and water samples. Several parameters affecting the extraction were optimized, such as sample pH, concentration of Triton X-114, extraction temperature and time, centrifugation rate and time, back-extraction solution pH, back-extraction temperature and time, back-extraction centrifugation rate and time. High performance liquid chromatography (HPLC) was applied for the SAs analysis. Under the optimum extraction and detection conditions, successful separation of the SAs was achieved within 9min, and excellent analytical performances were attained. Good linear relationships (R 2 ≥0.9990) between peak area and concentration for SMZ and STZ were optimized from 0.02 to 10μg/mL, for SDX from 0.01 to 10μg/mL. Detection limits of 3.0-6.2ng/mL were achieved. Satisfactory recoveries ranging from 85 to 108% were determined with urine, lake and tap water spiked at 0.2, 0.5 and 1μg/mL, respectively, with relative standard deviations (RSDs, n=6) of 1.5-7.7%. This method was demonstrated to be convenient, rapid, cost-effective and environmentally benign, and could be used as an alternative tool to existing methods for analysing trace residues of SAs in urine and water samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Chiral liquid chromatography-mass spectrometry (LC-MS/MS) method development for the detection of salbutamol in urine samples.

    Science.gov (United States)

    Chan, Sue Hay; Lee, Warren; Asmawi, Mohd Zaini; Tan, Soo Choon

    2016-07-01

    A sequential solid-phase extraction (SPE) method was developed and validated using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) for the detection and quantification of salbutamol enantiomers in porcine urine. Porcine urine samples were hydrolysed with β-glucuronidase/arylsulfatase from Helix pomatia and then subjected to a double solid-phase extraction (SPE) first using the Abs-Elut Nexus SPE and then followed by the Bond Elut Phenylboronic Acid (PBA) SPE. The salbutamol enantiomers were separated using the Astec CHIROBIOTIC™ T HPLC column (3.0mm×100mm; 5μm) maintained at 15°C with a 15min isocratic run at a flow rate of 0.4mL/min. The mobile phase constituted of 5mM ammonium formate in methanol. Salbutamol and salbutamol-tert-butyl-d9 (internal standard, IS) was monitored and quantified with the multiple reaction monitoring (MRM) mode. The method showed good linearity for the range of 0.1-10ng/mL with limit of quantification at 0.3ng/mL. Analysis of the QC samples showed intra- and inter-assay precisions to be less than 5.04%, and recovery ranging from 83.82 to 102.33%. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Iridium oxide pH sensor for biomedical applications. Case urea-urease in real urine samples.

    Science.gov (United States)

    Prats-Alfonso, Elisabet; Abad, Llibertat; Casañ-Pastor, Nieves; Gonzalo-Ruiz, Javier; Baldrich, Eva

    2013-01-15

    This work demonstrates the implementation of iridium oxide films (IROF) grown on silicon-based thin-film platinum microelectrodes, their utilization as a pH sensor, and their successful formatting into a urea pH sensor. In this context, Pt electrodes were fabricated on Silicon by using standard photolithography and lift-off procedures and IROF thin films were growth by a dynamic oxidation electrodeposition method (AEIROF). The AEIROF pH sensor reported showed a super-Nerstian (72.9±0.9mV/pH) response between pH 3 and 11, with residual standard deviation of both repeatability and reproducibility below 5%, and resolution of 0.03 pH units. For their application as urea pH sensors, AEIROF electrodes were reversibly modified with urease-coated magnetic microparticles (MP) using a magnet. The urea pH sensor provided fast detection of urea between 78μM and 20mM in saline solution, in sample volumes of just 50μL. The applicability to urea determination in real urine samples is discussed. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Metabolomics reveals dose effects of low-dose chronic exposure to uranium in rats: identification of candidate biomarkers in urine samples.

    Science.gov (United States)

    Grison, Stéphane; Favé, Gaëlle; Maillot, Matthieu; Manens, Line; Delissen, Olivia; Blanchardon, Éric; Dublineau, Isabelle; Aigueperse, Jocelyne; Bohand, Sandra; Martin, Jean-Charles; Souidi, Maâmar

    2016-01-01

    Data are sparse about the potential health risks of chronic low-dose contamination of humans by uranium (natural or anthropogenic) in drinking water. Previous studies report some molecular imbalances but no clinical signs due to uranium intake. In a proof-of-principle study, we reported that metabolomics is an appropriate method for addressing this chronic low-dose exposure in a rat model (uranium dose: 40 mg L -1 ; duration: 9 months, n = 10). In the present study, our aim was to investigate the dose-effect pattern and identify additional potential biomarkers in urine samples. Compared to our previous protocol, we doubled the number of rats per group (n = 20), added additional sampling time points (3 and 6 months) and included several lower doses of natural uranium (doses used: 40, 1.5, 0.15 and 0.015 mg L -1 ). LC-MS metabolomics was performed on urine samples and statistical analyses were made with SIMCA-P+ and R packages. The data confirmed our previous results and showed that discrimination was both dose and time related. Uranium exposure was revealed in rats contaminated for 9 months at a dose as low as 0.15 mg L -1 . Eleven features, including the confidently identified N1-methylnicotinamide, N1-methyl-2-pyridone-5-carboxamide and 4-hydroxyphenylacetylglycine, discriminated control from contaminated rats with a specificity and a sensitivity ranging from 83 to 96 %, when combined into a composite score. These findings show promise for the elucidation of underlying radiotoxicologic mechanisms and the design of a diagnostic test to assess exposure in urine, in a dose range experimentally estimated to be above a threshold between 0.015 and 0.15 mg L -1 .

  9. Identification and quantification of flavonoids in human urine samples by column switching liquid chromatography coupled to atmospheric pressure chemical ionization mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Salka E.; Freese, R.; Cornett, C.

    2000-01-01

    A rapid and sensitive high-performance liquid chromatographic mass spectrometric (HPLC-MS) method is described for the determination and quantification of 12 dietary flavonoid glycosides and aglycons in human urine samples. Chromatographic separation of the analytes of interest was achieved...

  10. Population variability of phthalate metabolites and bisphenol A concentrations in spot urine samples versus 24- or 48-h collections.

    Science.gov (United States)

    Christensen, Krista L Yorita; Lorber, Matthew; Koch, Holger M; Kolossa-Gehring, Marike; Morgan, Marsha K

    2012-11-01

    Human exposure to phthalates and bisphenol A (BPA) can be assessed through urinary biomonitoring, but methods to infer daily intakes assume that spot sample concentrations are comparable to daily average concentrations. We evaluate this assumption using human biomonitoring data from Germany and the United States (US). The German data comprised three regional studies with spot samples and one with full-day samples analyzed for phthalate metabolites. The US data included: a study on DEHP metabolites and BPA involving eight persons supplying all urine voids (from which 24-h samples were constructed) for seven consecutive days; NHANES spot sample data on DEHP metabolites and BPA; and a regional study of children with 48-h samples analyzed for BPA. In the German data, measures of central tendency differed, but spot and 24-h samples showed generally comparable variance including 95th percentiles and maxima equidistant from central tendency measures. In contrast, the US adult data from the eight-person study showed similar central tendencies for phthalate metabolites and BPA, but generally greater variability for the spot samples, including higher 95th percentiles and maxima. When comparing children's BPA concentrations in NHANES spot and 48-h samples, distributions showed similar central tendency and variability. Overall, spot urinary concentrations of DEHP metabolites and BPA have variability roughly comparable with corresponding 24-h average concentrations obtained from a comparable population, suggesting that spot samples can be used to characterize population distributions of intakes. However, the analysis also suggests that caution should be exercised when interpreting the high end of spot sample data sets.

  11. Molecularly imprinted polymer microspheres prepared by Pickering emulsion polymerization for selective solid-phase extraction of eight bisphenols from human urine samples

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jiajia [Key Laboratory of Separation Sciences for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian 116023 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Li, Yun; Wang, Jincheng [Key Laboratory of Separation Sciences for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian 116023 (China); Sun, Xiaoli; Cao, Rong [Key Laboratory of Separation Sciences for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian 116023 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Sun, Hao [Key Laboratory of Separation Sciences for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian 116023 (China); Department of Chemistry, Liaoning University, Shenyang 110000 (China); Huang, Chaonan [Key Laboratory of Separation Sciences for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian 116023 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Chen, Jiping, E-mail: chenjp@dicp.ac.cn [Key Laboratory of Separation Sciences for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian 116023 (China)

    2015-05-04

    Highlights: • BPA imprinted polymer microspheres were prepared by Pickering emulsion polymerization. • Regular spherical shape and narrow diameter distribution. • Good specific adsorption capacity for BPA. • Good class-selectivity and clean-up efficiency for bisphenols in human urine under SPE mode. • Good recoveries and sensitivity for bisphenols using the MIPMS-SPE coupled with HPLC-DAD method. - Abstract: The bisphenol A (BPA) imprinted polymer microspheres were prepared by simple Pickering emulsion polymerization. Compared to traditional bulk polymerization, both high yields of polymer and good control of particle sizes were achieved. The characterization results of scanning electron microscopy and nitrogen adsorption–desorption measurements showed that the obtained molecularly imprinted polymer microsphere (MIPMS) particles possessed regular spherical shape, narrow diameter distribution (30–60 μm), a specific surface area (S{sub BET}) of 281.26 m{sup 2} g{sup −1} and a total pore volume (V{sub t}) of 0.459 cm{sup 3} g{sup −1}. Good specific adsorption capacity for BPA was obtained in the sorption experiment and good class selectivity for BPA and its seven structural analogs (bisphenol F, bisphenol B, bisphenol E, bisphenol AF, bisphenol S, bisphenol AP and bisphenol Z) was demonstrated by the chromatographic evaluation experiment. The MIPMS as solid-phase extraction (SPE) packing material was then evaluated for extraction and clean-up of these bisphenols (BPs) from human urine samples. An accurate and sensitive analytical method based on the MIPMS-SPE coupled with HPLC-DAD has been successfully established for simultaneous determination of eight BPs from human urine samples with detection limits of 1.2–2.2 ng mL{sup −1}. The recoveries of BPs for urine samples at two spiking levels (100 and 500 ng mL{sup −1} for each BP) were in the range of 81.3–106.7% with RSD values below 8.3%.

  12. Utilizing Estimated Creatinine Excretion to Improve the Performance of Spot Urine Samples for the Determination of Proteinuria in Kidney Transplant Recipients.

    Directory of Open Access Journals (Sweden)

    Michael Ke Wang

    Full Text Available Agreement between spot and 24-hour urine protein measurements is poor in kidney transplant recipients. We investigated whether using formulae to estimate creatinine excretion rate (eCER, rather than assuming a standard creatinine excretion rate, would improve the estimation of proteinuria from spot urine samples in kidney transplant recipients.We measured 24 hour urine protein and albumin and spot albumin:creatinine (ACR and spot protein:creatinine (PCR in 181 Kidney transplant recipients." We utilized 6 different published formulae (Fotheringham, CKD-EPI, Cockcroft-Gault, Walser, Goldwasser and Rule to estimate eCER and from it calculated estimated albumin and protein excretion rate (eAER and ePER. Bias, precision and accuracy (within 15%, 30% and 50% of ACR, PCR, eAER, ePER were compared to 24-hour urine protein and albumin.ACR and PCR significantly underestimated 24-hour albumin and protein excretion (ACR Bias (IQR, -5.9 mg/day; p< 0.01; PCR Bias, (IQR, -35.2 mg/day; p<0.01. None of the formulae used to calculate eAER or ePER had a bias that was significantly different from the 24-hour collection (eAER and ePER bias: Fotheringham -0.3 and 7.2, CKD-EPI 0.3 and 13.5, Cockcroft-Gault -3.2 and -13.9, Walser -1.7 and 3.1, Goldwasser -1.3 and -0.5, Rule -0.6 and 4.2 mg/day respectively. The accuracy for ACR and PCR were lower (within 30% being 38% and 43% respectively than the corresponding values estimated by utilizing eCER (for eAER 46% to 49% and ePER 46-54%.Utilizing estimated creatinine excretion to calculate eAER and ePER improves the estimation of 24-hour albuminuria/proteinuria with spot urine samples in kidney transplant recipients.

  13. Epidemiological investigation of the UGT2B17 polymorphism in doping control urine samples and its correlation to T/E ratios.

    Science.gov (United States)

    Anielski, Patricia; Simmchen, Juliane; Wassill, Lars; Ganghofner, Dirk; Thieme, Detlef

    2011-10-01

    The deletion polymorphism of the enzyme UGT2B17 is known to correlate with the level of the testosterone to epitestosterone (T/E) ratio in urine specimen. Due to the importance of the T/E ratio to detect testosterone abuse in doping analysis, a PCR-ELISA system (Genotype® UGT test, AmplexDiagnostics) was established to identify the UGT2B17 phenotype in urine samples. Epidemiological investigations in a set of 674 routine doping controls (in- and out-of-competition) resulted in 22.8% homozygote gene-deleted and 74.5% UGT2B17-positive athletes. The validated test system has shown to be robust and sensitive: in only 18 cases (2.7%) isolation of cell material from urine failed. Following hydrolysis of glucuronidated conjugates, steroids were analyzed as bis-TMS derivatives by gas chromatography-mass spectrometry (GC-MS), for example, testosterone (T) and epitestosterone (E). Additionally, isotope ration mass spectrometry (IRMS) analysis and luteinizing hormone (LH) measurement were applied. Mean T/E ratios significantly correlated with the UGT2B17 phenotype (del: T/E 0.9; pos: 1.7), however the values did not differ as distinctive as reported in previous studies. Additionally, the T/E ratios in the gene-deleted group did not show a normal curve of distribution (median of T/E 0.5). Obviously, beside the UGT2B17 deletion further influences have to be taken into account, for example, polymorphisms or induction of other metabolizing enzymes. Our results indicate that the UGT2B17 polymorphism might be insufficient when utilized solely as a crucial parameter for individual interpretation of T/E in urine. Nevertheless, the detection of the UGT2B17-gene deletion in urine samples would provide additional information important for gathering evidence in analysis of steroids in doping control. Copyright © 2011 John Wiley & Sons, Ltd.

  14. Validation and Assessment of Three Methods to Estimate 24-h Urinary Sodium Excretion from Spot Urine Samples in High-Risk Elder Patients of Stroke from the Rural Areas of Shaanxi Province.

    Science.gov (United States)

    Ma, Wenxia; Yin, Xuejun; Zhang, Ruijuan; Liu, Furong; Yang, Danrong; Fan, Yameng; Rong, Jie; Tian, Maoyi; Yu, Yan

    2017-10-11

    Background : 24-h urine collection is regarded as the "gold standard" for monitoring sodium intake at the population level, but ensuring high quality urine samples is difficult to achieve. The Kawasaki, International Study of Sodium, Potassium, and Blood Pressure (INTERSALT) and Tanaka methods have been used to estimate 24-h urinary sodium excretion from spot urine samples in some countries, but few studies have been performed to compare and validate these methods in the Chinese population. Objective : To compare and validate the Kawasaki, INTERSALT and Tanaka formulas in predicting 24-h urinary sodium excretion using spot urine samples in 365 high-risk elder patients of strokefrom the rural areas of Shaanxi province. Methods : Data were collected from a sub-sample of theSalt Substitute and Stroke Study. 365 high-risk elder patients of stroke from the rural areas of Shaanxi province participated and their spot and 24-h urine specimens were collected. The concentrations of sodium, potassium and creatinine in spot and 24-h urine samples wereanalysed. Estimated 24-h sodium excretion was predicted from spot urine concentration using the Kawasaki, INTERSALT, and Tanaka formulas. Pearson correlation coefficients and agreement by Bland-Altman method were computed for estimated and measured 24-h urinary sodium excretion. Results : The average 24-h urinary sodium excretion was 162.0 mmol/day, which representing a salt intake of 9.5 g/day. Three predictive equations had low correlation with the measured 24-h sodium excretion (r = 0.38, p h sodium excretion were observed (all p h sodium excretion. Conclusion : The Kawasaki, INTERSALT and Tanaka methods for estimation of 24-h urinary sodium excretion from spot urine specimens were inadequate for the assessment of sodium intake at the population level in high-risk elder patients of stroke from the rural areas of Shaanxi province, although the Kawasaki method was the least biased compared with the other two methods.

  15. Optimized preparation of urine samples for two-dimensional electrophoresis and initial application to patient samples

    DEFF Research Database (Denmark)

    Lafitte, Daniel; Dussol, Bertrand; Andersen, Søren

    2002-01-01

    OBJECTIVE: We optimized of the preparation of urinary samples to obtain a comprehensive map of urinary proteins of healthy subjects and then compared this map with the ones obtained with patient samples to show that the pattern was specific of their kidney disease. DESIGN AND METHODS: The urinary...

  16. A competitive immunoassay for ultrasensitive detection of Hg"2"+ in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering

    International Nuclear Information System (INIS)

    She, Pei; Chu, Yanxin; Liu, Chunwei; Guo, Xun; Zhao, Kang; Li, Jianguo; Du, Haijing; Zhang, Xiang; Wang, Hong; Deng, Anping

    2016-01-01

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg"2"+. This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg"2"+ and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg"2"+. The ICT was able to directly detect Hg"2"+ without complexing due to the specific recognition of the mAb with Hg"2"+. The IC_5_0 and limit of detection (LOD) of the assay for Hg"2"+ detection were 0.12 ng mL"−"1 and 0.45 pg mL"−"1, respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg"2"+ were in range of 88.3–107.3% with the relative standard deviations (RSD) of 1.5–9.5% (n = 3). The proposed ICT was used for the detection of Hg"2"+ in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg"2"+ in environmental water samples and biological serum and urine samples. - Highlights: • The proposed ICT was able to directly detect Hg"2"+ without formation of Hg"2"+-ligand complex. • The proposed ICT exhibited high sensitivity, specificity, stability, precision and accuracy for Hg"2"+ detection. • The proposed ICT was applicable for the detection of trace amount of Hg"2"+ in water, human serum and urine samples.

  17. Enantioselective extraction of (+)-(S)-citalopram and its main metabolites using a tailor-made stir bar chiral imprinted polymer for their LC-ESI-MS/MS quantitation in urine samples.

    Science.gov (United States)

    Unceta, Nora; Gómez-Caballero, Alberto; García, Deiene; Díaz, Goretti; Guerreiro, Antonio; Piletsky, Sergey; Goicolea, M Aránzazu; Barrio, Ramón J

    2013-11-15

    This paper reports the application of a chiral imprinted polymer (CIP)-coated stir bar for the selective extraction of (+)-(S)-citalopram (SCIT) and its main metabolites, (+)-(S)-desmethylcitalopram (SDCIT) and (+)-(S)-didesmethylcitalopram (SDDCIT), from urine samples. The developed device has been demonstrated to be capable of selectively extracting the three target analytes from urine samples without saturating the imprinted sites. A CIP-coated stir bar sorptive extraction procedure (CIP-SBSE) is proposed for the isolation of SCIT, SDCIT and SDDCIT followed by their subsequent analysis using liquid chromatography ion trap mass spectrometry (LC-ITMS). Deuterated SCIT-d6 was used as an internal standard. The method was validated using a standard procedure, which revealed that a quantification of 5 ng mL(-1) was obtained in urine samples and that the accuracy and precision were within the established values while no matrix effect was observed. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. A novel fast method for aqueous derivatization of THC, OH-THC and THC-COOH in human whole blood and urine samples for routine forensic analyses.

    Science.gov (United States)

    Stefanelli, Fabio; Pesci, Federica Giorgia; Giusiani, Mario; Chericoni, Silvio

    2018-04-01

    A novel aqueous in situ derivatization procedure with propyl chloroformate (PCF) for the simultaneous, quantitative analysis of Δ 9 -tetrahydrocannabinol (THC), 11-hydroxy-Δ 9 -tetrahydrocannabinol (OH-THC) and 11-nor-Δ 9 -tetrahydrocannabinol-carboxylic acid (THC-COOH) in human blood and urine is proposed. Unlike current methods based on the silylating agent [N,O-bis(trimethylsilyl)trifluoroacetamide] added in an anhydrous environment, this new proposed method allows the addition of the derivatizing agent (propyl chloroformate, PCF) directly to the deproteinized blood and recovery of the derivatives by liquid-liquid extraction. This novel method can be also used for hydrolyzed urine samples. It is faster than the traditional method involving a derivatization with trimethyloxonium tetrafluoroborate. The analytes are separated, detected and quantified by gas chromatography-mass spectrometry in selected ion monitoring mode (SIM). The method was validated in terms of selectivity, capacity of identification, limits of detection (LOD) and quantification (LOQ), carryover, linearity, intra-assay precision, inter-assay precision and accuracy. The LOD and LOQ in hydrolyzed urine were 0.5 and 1.3 ng/mL for THC and 1.2 and 2.6 ng/mL for THC-COOH, respectively. In blood, the LOD and LOQ were 0.2 and 0.5 ng/mL for THC, 0.2 and 0.6 ng/mL for OH-THC, and 0.9 and 2.4 ng/mL for THC-COOH, respectively. This method was applied to 35 urine samples and 50 blood samples resulting to be equivalent to the previously used ones with the advantage of a simpler method and faster sample processing time. We believe that this method will be a more convenient option for the routine analysis of cannabinoids in toxicological and forensic laboratories. Copyright © 2017 John Wiley & Sons, Ltd.

  19. Pressure-assisted introduction of urine samples into a short capillary for electrophoretic separation with contactless conductivity and UV spectrometry detection.

    Science.gov (United States)

    Makrlíková, Anna; Opekar, František; Tůma, Petr

    2015-08-01

    A computer-controlled hydrodynamic sample introduction method has been proposed for short-capillary electrophoresis. In the method, the BGE flushes sample from the loop of a six-way sampling valve and is carried to the injection end of the capillary. A short pressure impulse is generated in the electrolyte stream at the time when the sample zone is at the capillary, leading to injection of the sample into the capillary. Then the electrolyte flow is stopped and the separation voltage is turned on. This way of sample introduction does not involve movement of the capillary and both of its ends remain constantly in the solution during both sample injection and separation. The amount of sample introduced to the capillary is controlled by the duration of the pressure pulse. The new sample introduction method was tested in the determination of ammonia, creatinine, uric acid, and hippuric acid in human urine. The determination was performed in a capillary with an overall length of 10.5 cm, in two BGEs with compositions 50 mM MES + 5 mM NaOH (pH 5.1) and 1 M acetic acid + 1.5 mM crown ether 18-crown-6 (pH 2.4). A dual contactless conductivity/UV spectrometric detector was used for the detection. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Identification of AKB-48 and 5F-AKB-48 Metabolites in Authentic Human Urine Samples Using Human Liver Microsomes and Time of Flight Mass Spectrometry.

    Science.gov (United States)

    Vikingsson, Svante; Josefsson, Martin; Gréen, Henrik

    2015-01-01

    The occurrence of structurally related synthetic cannabinoids makes the identification of unique markers of drug intake particularly challenging. The aim of this study was to identify unique and abundant metabolites of AKB-48 and 5F-AKB-48 for toxicological screening in urine. Investigations of authentic urine samples from forensic cases in combination with human liver microsome (HLM) experiments were used for identification of metabolites. HLM incubations of AKB-48 and 5F-AKB-48 along with 35 urine samples from authentic cases were analyzed with liquid chromatography quadrupole tandem time of flight mass spectrometry. Using HLMs 41 metabolites of AKB-48 and 37 metabolites of 5F-AKB-48 were identified, principally represented by hydroxylation but also ketone formation and dealkylation. Monohydroxylated metabolites were replaced by di- and trihydroxylated metabolites within 30 min. The metabolites from the HLM incubations accounted for on average 84% (range, 67-100) and 91% (range, 71-100) of the combined area in the case samples for AKB-48 and 5F-AKB-48, respectively. While defluorinated metabolites accounted for on average 74% of the combined area after a 5F-AKB-48 intake only a few identified metabolites were shared between AKB-48 and 5F-AKB-48, illustrating the need for a systematic approach to identify unique metabolites. HLMs in combination with case samples seem suitable for this purpose. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Simultaneous determination of morphine, codeine and 6-acetyl morphine in human urine and blood samples using direct aqueous derivatisation: validation and application to real cases.

    Science.gov (United States)

    Chericoni, S; Stefanelli, F; Iannella, V; Giusiani, M

    2014-02-15

    Opiates play a relevant role in forensic toxicology and their assay in urine or blood is usually performed for example in workplace drug-testing or toxicological investigation of drug impaired driving. The present work describes two new methods for detecting morphine, codeine and 6-monoacethyl morphine in human urine or blood using a single step derivatisation in aqueous phase. Propyl chloroformate is used as the dramatizing agent followed by liquid-liquid extraction and gas-chromatography-mass spectroscopy to detect the derivatives. The methods have been validated both for hydrolysed and unhydrolysed urine. For hydrolysed urine, the LOD and LOQ were 2.5ng/ml and 8.5ng/ml for codeine, and 5.2ng/ml and 15.1ng/ml for morphine, respectively. For unhydrolysed urine, the LOD and LOQ were 3.0ng/ml and 10.1ng/ml for codeine, 2.7ng/ml and 8.1ng/ml for morphine, 0.8ng/ml and 1.5ng/ml for 6-monoacetyl morphine, respectively. In blood, the LOD and LOQ were 0.44ng/ml and 1.46ng/ml for codeine, 0.29ng/ml and 0.98ng/ml for morphine, 0.15ng/ml and 0.51ng/ml for 6-monoacetyl morphine, respectively. The validated methods have been applied to 50 urine samples and 40 blood samples (both positive and negative) and they can be used in routine analyses. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Temporal variability in urinary excretion of bisphenol A and seven other phenols in spot, morning, and 24-h urine samples

    DEFF Research Database (Denmark)

    Lassen, Tina Harmer; Frederiksen, Hanne; Jensen, Tina Kold

    2013-01-01

    (ICCs). More than 70% of the urine samples had detectable levels of BPA, triclosan (TCS), benzophenone-3 (BP-3) and sum of 2,4-dichlorophenol and 2,5-dichlorophenol (ΣDCP). We found low to moderate ICCs for BPA (0.10-0.42) and ΣDCP (0.39-0.72), whereas the ICCs for BP-3 (0.69-0.80) and TCS (0...

  3. Urine Tests (For Parents)

    Science.gov (United States)

    ... the urine sample. In certain situations, a sterile bag can be placed around a baby’s diaper area to collect a urine sample. If you have any questions about urine tests, talk with your doctor. Reviewed by: Yamini Durani, MD ...

  4. [Comparison and evaluation of the Binax EIA and Biotest EIA urinary antigen kits for detection of Legionella pneumophila antigen in urine samples].

    Science.gov (United States)

    Rastawicki, Waldemar; Rokosz, Natalia; Jagielski, Marek

    2011-01-01

    The Binax and the Biotest urinary antigen kits for detection of L. pneumophila antigen were compared by testing of selected 67 urine samples obtained from EWGLI as reference samples in External Quality Assessment Scheme. Thirty nine were positive with the Binax kit (100% of sensitivity), and 33 were positive with the Biotest (84.6% of sensitivity). The test specificities were 100% for the both kits. It was concluded that the Binax kit was more suitable for the routine diagnosis of Legionella infections than the Biotest kit.

  5. Detection of the antipsychotic drug quetiapine in the blood, urine and hair samples of the victim of a drug-facilitated sexual assault

    DEFF Research Database (Denmark)

    Johansen, Sys Stybe

    2017-01-01

    A drug rape facilitated with the sedative antipsychotic drug quetiapine is presented here. A teenage girl and her girlfriend went to the home of an adult couple they had met at a bar. Here, the teenage girl (victim) felt tired after consuming some alcoholic drinks and fell asleep. While she......-three hours after the suspected drug-facilitated sexual assault (DFSA), blood and urine samples were collected and the initial toxicological screening detected quetiapine. Confirmation and quantification by ultra high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) revealed...... a concentration of 0.007mg/kg quetiapine in blood and 0.19mg/l in urine. Six months after the DFSA, a hair sample was collected and segmental hair analysis was performed on four washed segments (0-3cm, 3-5cm, 5-7cm, and 7-9cm). The last segment contained 0.011ng/mg of quetiapine, whereas the other segments were...

  6. Simultaneous determination of hydroxycinnamates and catechins in human urine samples by column switching liquid chromatography coupled to atmospheric pressure chemical ionization mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Salka E.; Sandström, B.

    2003-01-01

    A quantitative liquid chromatography mass spectrometry (LC-MS) methodology with online sample clean up by column switching is described for the simultaneous determination of the hydroxycinnamates, caffeic acid and chlorogenic acid, and of the catechins, epicatechin and catechin in human urine...

  7. Molecularly Imprinted Polymers (MIP for Selective Solid Phase Extraction of Celecoxib in Urine Samples Followed by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Saeedeh Ansari

    2017-09-01

    Full Text Available In this study, for the analysis of human urine samples, a novel method explained for the determination of celecoxib, a nonsteroidal anti-inflammatory drug (NSAID, using molecularly imprinted solid-phase extraction (MISPE coupled with high-performance liquid chromatography (HPLC. The synthesis of the MIP was performed by precipitation polymerization in methacrylic acid (MAA, ethylene glycol dimethacrylate (EGDMA, chloroform, 2,2′-azobisisobutyronitrile (AIBN and celecoxib as the functional monomer, cross-linker monomer, solvent, initiator and target drug, respectively. The celecoxib imprinted polymer was utilized as a specific sorbent for the solid phase extraction (SPE of celecoxib from samples. The molecularly imprinted polymer (MIP performance was compared with the synthesized non-molecularly imprinted polymer (NIP. Scanning electron microscopy (SEM, FT-IR spectroscopy, UV-VIS spectrophotometry and thermogravimetric analysis (TGA/DTG were used for characterizing the synthesized polymers. Moreover, the MISPE procedure parameters such as pH, eluent solvent flow rate, eluent volume and sorbent mass that probably influence the extraction process have been optimized to achieve the highest celecoxib extraction efficiency. The relative standard deviation (RSD %, recovery percent, limit of detection (LOD and limit of quantification (LOQ of this proposed method were 1.12%, 96%, 8 µg L-1 and 26.7 µg L-1, respectively. The proposed MISPE-HPLC-UV method can be used for the separation and enrichment of trace amounts of celecoxib in human urine and biological samples.

  8. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF URINE SAMPLES FOR METALS AND PESTICIDES ANALYSIS (UA-F-20.1)

    Science.gov (United States)

    The purpose of this SOP is to guide the collection, storage, and shipment of urine samples collected. This SOP provides a brief description of sample, collection, preservation, storage, shipping, and custody procedures. This procedure was followed to ensure consistent data retri...

  9. Development of SPME-LC-MS method for screening of eight beta-blockers and bronchodilators in plasma and urine samples.

    Science.gov (United States)

    Goryński, Krzysztof; Kiedrowicz, Alicja; Bojko, Barbara

    2016-08-05

    The current work describes the development and validation of a simple, efficient, and fast method using solid phase microextraction coupled to liquid chromatography-tandem mass spectrometry (SPME-LC-MS/MS) for the concomitant measurement of eight beta-blockers and bronchodilators in plasma and urine. The presented assay enables quantitative determination of acebutolol, atenolol, fenoterol, nadolol, pindolol, procaterol, sotalol, and timolol. In this work, samples were prepared on a high-throughput platform using the 96-well plate format of the thin film solid phase microextraction (TFME) system, and a biocompatible extraction phase made of hydrophilic-lipophilic balance particles. Analytes were separated on a pentafluorophenyl column (100mm×2.1mm, 3μm) by gradient elution using an UPLC Nexera coupled with an LCMS-8060 mass spectrometer. The mobile phase consisted of water-acetonitrile (0.1% formic acid) at a flow rate of 0.4mLmin(-1). The linearity of the method was checked within therapeutic blood-plasma concentrations, and shown to adequately reflect typically expected concentrations of future study samples. Post-extraction addition experiments showed that the matrix effect ranged in plasma from 98% for procaterol to 115% for nadolol, and in urine, from 85% for nadolol and pindolol to 119% for atenolol. The method was successfully validated using Food and Drug Administration (FDA) guidelines, and met all acceptance criteria for bioanalytical assays at five concentration levels for all selected drugs. The final protocol can be successfully applied for monitoring concentrations of the selected drugs in both plasma and urine matrices obtained from patients or athletes. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Parabens in 24 h urine samples of the German Environmental Specimen Bank from 1995 to 2012.

    Science.gov (United States)

    Moos, Rebecca K; Koch, Holger M; Angerer, Jürgen; Apel, Petra; Schröter-Kermani, Christa; Brüning, Thomas; Kolossa-Gehring, Marike

    2015-10-01

    Parabens are widely used as antimicrobial preservatives in personal care and consumer products, food and pharmaceuticals. Due to their ubiquity, humans are constantly exposed to these chemicals. We assessed exposure to nine parabens (methyl-, ethyl-, n- and iso-propyl-, n- and iso-butyl-, benzyl-, pentyl- and heptyl paraben) in the German population from 1995 to 2012 based on 660 24h urine samples from the German Environmental Specimen Bank (ESB) using on-line HPLC coupled to isotope dilution tandem mass spectrometry. The limit of quantification (LOQ) was 0.5 μg/L for all parabens. We detected methyl-, ethyl- and n-propyl paraben in 79-99% of samples, followed by n-butyl paraben in 40% of samples. We infrequently detected iso-butyl-, iso-propyl- and benzyl paraben in 24%, 4% and 1.4% of samples, respectively. Urinary concentrations were highest for methyl paraben (median 39.8 μg/L; 95th percentile 319 μg/L) followed by n-propyl paraben (4.8 μg/L; 95th percentile 74.0 μg/L) and ethyl paraben (2.1 μg/L; 95th percentile 39.1 μg/L). Women had significantly higher urinary levels for all parabens than men, except for benzyl paraben. Samples from the ESB revealed that over the investigation period of nearly 20 years urinary paraben levels remained surprisingly constant; only methyl paraben had a significant increase, for both men and women. We found strong correlations between methyl- and n-propyl paraben and between n- and iso-butyl paraben. These results indicate that parabens are used in combination and arise from common sources of exposure. Urinary excretion factors are needed to extrapolate from individual urinary concentrations to actual doses. Copyright © 2015 Elsevier GmbH. All rights reserved.

  11. Detection and genotyping of human papillomavirus in urine samples from unvaccinated male and female adolescents in Italy.

    Directory of Open Access Journals (Sweden)

    Silvia Bianchi

    Full Text Available The introduction of vaccination against Human Papillomavirus (HPV in adolescent girls in 2006 has focused virological surveillance on this age group. As few studies have evaluated HPV infections in young populations, further data are needed in order to improve and extend prophylactic policy and to monitor epidemiological changes. The present study aimed at evaluating overall and type-specific HPV prevalence in both female and male adolescents in Italy. HPV DNA detection and genotyping was performed on urine samples collected from 870 unvaccinated adolescents (369 females, 501 males, 11-18 years of age in five cities in Italy. Following DNA extraction by means of a commercial kit (NucliSENS(®-miniMAG(®, bioMérieux, the L1 gene fragment was PCR amplified and genotyped by restriction fragment length polymorphism analysis. HPV DNA was detected in 1.5% of all samples, and in 3% and 0.4% of samples from females and males, respectively. In approximately 70% of HPV DNA positive adolescents, the infection was due to a single genotype, with 88.9% of genotypes belonging to the HR-clade. The only two HPV-positive boys (14 and 18 years old had HPV-70 genotype. Only one of the 11 HPV-infected girls was in the 11-14 age-group. HPV prevalence was 4.2% in girls aged 15-18 years and 60% of infections were due to vaccine types HPV-16 or HPV-6/-11. This is one of the few studies, the first conducted in Italy, on HPV infection in adolescents. Urine testing is the easier way of detecting HPV infection in younger populations. Our data revealed a very low HPV prevalence, and no infections were observed in the 12-year-old vaccine target population. The majority of infections were seen in females aged 15-18 years. Overall, more than 50% and 30% of the potentially persistent HPV infections detected in this group could have been prevented by the quadrivalent and the bivalent vaccines, respectively.

  12. Detection and genotyping of human papillomavirus in urine samples from unvaccinated male and female adolescents in Italy.

    Science.gov (United States)

    Bianchi, Silvia; Frati, Elena Rosanna; Panatto, Donatella; Martinelli, Marianna; Amicizia, Daniela; Zotti, Carla Maria; Martinese, Morena; Bonanni, Paolo; Boccalini, Sara; Coppola, Rosa Cristina; Masia, Giuseppina; Meloni, Angelo; Castiglia, Paolo; Piana, Andrea; Gasparini, Roberto; Tanzi, Elisabetta

    2013-01-01

    The introduction of vaccination against Human Papillomavirus (HPV) in adolescent girls in 2006 has focused virological surveillance on this age group. As few studies have evaluated HPV infections in young populations, further data are needed in order to improve and extend prophylactic policy and to monitor epidemiological changes. The present study aimed at evaluating overall and type-specific HPV prevalence in both female and male adolescents in Italy. HPV DNA detection and genotyping was performed on urine samples collected from 870 unvaccinated adolescents (369 females, 501 males, 11-18 years of age) in five cities in Italy. Following DNA extraction by means of a commercial kit (NucliSENS(®)-miniMAG(®), bioMérieux), the L1 gene fragment was PCR amplified and genotyped by restriction fragment length polymorphism analysis. HPV DNA was detected in 1.5% of all samples, and in 3% and 0.4% of samples from females and males, respectively. In approximately 70% of HPV DNA positive adolescents, the infection was due to a single genotype, with 88.9% of genotypes belonging to the HR-clade. The only two HPV-positive boys (14 and 18 years old) had HPV-70 genotype. Only one of the 11 HPV-infected girls was in the 11-14 age-group. HPV prevalence was 4.2% in girls aged 15-18 years and 60% of infections were due to vaccine types HPV-16 or HPV-6/-11. This is one of the few studies, the first conducted in Italy, on HPV infection in adolescents. Urine testing is the easier way of detecting HPV infection in younger populations. Our data revealed a very low HPV prevalence, and no infections were observed in the 12-year-old vaccine target population. The majority of infections were seen in females aged 15-18 years. Overall, more than 50% and 30% of the potentially persistent HPV infections detected in this group could have been prevented by the quadrivalent and the bivalent vaccines, respectively.

  13. Simultaneous Determination of Ibuprofen and Caffeine in Urine Samples by Combining MCR-ALS and Excitation-emission Data

    Directory of Open Access Journals (Sweden)

    Masoumeh Mohammadnejad

    2016-06-01

    Full Text Available Second order advantage of excitation-emission fluorescence matrix was applied for the simultaneous determination of ibuprofen and caffeine. The proposed method is based on the measurement of the native fluorescence and recording emission spectra of ibuprofen and caffeine in different excitation wavelengths. The mixture of these compounds was resolved by multivariate curve resolution coupled with alternative least squares (MCR-ALS on constructed matrix. The EEM spectra were recorded at excitation wavelengths from 250-275 nm; the emission wavelengths ranged from 275-400 nm. For each particular quantitative determination, an augmented matrix was defined. The resolution of each augmented-data matrix gave an estimation of the excitation and emission spectra of the species included in the model. Ibuprofen and caffeine were determined in concentration range from 0.10-8.00 and 0.50-15.00 mg ml-1, respectively. The minimal sample pretreatment and relatively low running cost, make this method a good alternative to existing methods for determination of the analytes in urine samples.

  14. Microextraction by Packed Sorbent (MEPS and Solid-Phase Microextraction (SPME as Sample Preparation Procedures for the Metabolomic Profiling of Urine

    Directory of Open Access Journals (Sweden)

    Catarina Silva

    2014-01-01

    Full Text Available For a long time, sample preparation was unrecognized as a critical issue in the analytical methodology, thus limiting the performance that could be achieved. However, the improvement of microextraction techniques, particularly microextraction by packed sorbent (MEPS and solid-phase microextraction (SPME, completely modified this scenario by introducing unprecedented control over this process. Urine is a biological fluid that is very interesting for metabolomics studies, allowing human health and disease characterization in a minimally invasive form. In this manuscript, we will critically review the most relevant and promising works in this field, highlighting how the metabolomic profiling of urine can be an extremely valuable tool for the early diagnosis of highly prevalent diseases, such as cardiovascular, oncologic and neurodegenerative ones.

  15. A follow-up urine sample has limited value after treatment for urinary tract infection in children.

    Science.gov (United States)

    Lytzen, Rebekka; Kaalund-Jørgensen, Kristine; Ahmed, Akhlaq; Abd-El-Redda, Haidar Karim; Thorup, Jørgen; Knudsen, Jenny Dahl; Cortes, Dina

    2015-01-01

    A routine follow-up urine sample (FUS) in the form of a midstream urine sample (MSU) is recommended after treatment for urinary tract infection (UTI) according to the Danish Paediatric Society (DPS) and "Lægehåndbogen" published by Danish Regions. We studied the effect of FUS with a focus on patients without symptoms at the time of FUS. Consecutive patients below 16.0 years treated for upper or lower UTI from 1 January 2009 to 31 December 2009 at Hvidovre Hospital in accordance with the guidelines of the department and the DPS. All patients were asked to provide a FUS within 21 days. A total of 87 patients were treated for upper UTI: 59 girls and 28 boys, the median age was 1.1 year (range: 0.1-15.6 years); and 42 girls were treated for lower UTI, their median age was 8.2 years (range: 2.5-15.3 years). After treatment, the risk of a UTI was 0% (0/87) after upper UTI versus 19% (8/42) after lower UTI (Fisher's exact test (FE), p UTI was 0% (0/75) (95% confidence interval (CI): 0-4.9%) after upper UTI versus 4% (1/26) (95% CI: 0.1-19.6%) after lower UTI (FE, p = 0.2754). The cost of requesting a FUS in patients without symptoms was 166 euro after treatment for upper UTI and 66 euro after treatment of lower UTI. We do not recommend a FUS after treatment for UTI as the 95% CI of risk of missing UTI after treatment for upper UTI was below 5%. This strategy will save the patients/families and the health-care system. However, if a child has symptoms after treatment for UTI, it must be examined. not relevant. The study was approved by the Danish Data Protection Agency (J. no. 2007-58-0015).

  16. Evaluation of the use of purine derivatives:creatinine ratio in spot urine samples as an index of microbial protein supply in Yerli Kara crossbred cattle

    International Nuclear Information System (INIS)

    Cetinkaya, N.; Ozdemir, H.; Gucus, A.I.; Ozcan, H.; Sogut, A.; Yaman, S.

    2004-01-01

    In Experiment I, response of daily purine derivatives (PD) excretion to feed intake in Yerli Kara crossbred (YK-C) cattle on state farms was measured. Animals were fed a mixed diet containing 30% wheat straw and 70% compounded feed. Crude protein and organic matter contents of the diet were 12.4% and 95%, respectively. In Experiment II, spot urine sampling technique was applied at state farm. Four Yerli Kara crossbred bulls with a mean live weight of 211.0 ± 41.3 kg were used. The experimental design, feeding and diet were the same as in Experiment I. The treatments were allocated according to a 4 x 4 Latin Square design. In Experiment III, spot urine sampling technique was applied at smallholder farms. Two to three kg of compound feed (crude protein 12%) containing 65% barley, 25% bran, 6% sunflower seed meal, 3% marmer dust and 1% mineral and vitamin mixture was offered in two parts, one in the morning (0730 h) and the other in the afternoon (1700 h). The ingredients in the compound feed were similar for all animals, but animals in Groups I, II and III received 1 to 2 kg/d of straw (crude protein 3%), grass hay (crude protein 7%), or both straw and grass hay respectively. In Experiment I, a significant correlation (R 2 =0.99) between PD excretion (Y, mmol/d) and digestible organic matter intake, DOMI (X, kg/d) for YK-C cattle was observed (Y = 12.5 + 19.7 X). Moreover, daily PD excretion (mmol/d) was correlated with the PDC index, which was defined as [PD molar concentration] / [Creatinine molar concentration] x kgW 0.75 . In Experiment II, the PDC index increased with level of intake. The coefficient of variation due to time of sampling for uric acid, allantoin, PD, creatinine, total-N, the PDC Index in spot urine samples were less than 5%. In Experiment III, the PDC index were 49.95 ± 13.5, 45.6 ± 13.0, 48.95 ± 15.3 for the three groups respectively. These values were similar to those for 60% intake level in Experiment I. Using the equation DOMI = 344 + 48

  17. Simultaneous extraction and quantification of lamotrigine, phenobarbital, and phenytoin in human plasma and urine samples using solidified floating organic drop microextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Asadi, Mohammad; Dadfarnia, Shayessteh; Haji Shabani, Ali Mohammad; Abbasi, Bijan

    2015-07-01

    A novel and simple method based on solidified floating organic drop microextraction followed by high-performance liquid chromatography with ultraviolet detection has been developed for simultaneous preconcentration and determination of phenobarbital, lamotrigine, and phenytoin in human plasma and urine samples. Factors affecting microextraction efficiency such as the type and volume of the extraction solvent, sample pH, extraction time, stirring rate, extraction temperature, ionic strength, and sample volume were optimized. Under the optimum conditions (i.e. extraction solvent, 1-undecanol (40 μL); sample pH, 8.0; temperature, 25°C; stirring rate, 500 rpm; sample volume, 7 mL; potassium chloride concentration, 5% and extraction time, 50 min), the limits of detection for phenobarbital, lamotrigine, and phenytoin were 1.0, 0.1, and 0.3 μg/L, respectively. Also, the calibration curves for phenobarbital, lamotrigine, and phenytoin were linear in the concentration range of 2.0-300.0, 0.3-200.0, and 1.0-200.0 μg/L, respectively. The relative standard deviations for six replicate extractions and determinations of phenobarbital, lamotrigine, and phenytoin at 50 μg/L level were less than 4.6%. The method was successfully applied to determine phenobarbital, lamotrigine, and phenytoin in plasma and urine samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Measurements of purine derivatives and creatinine in spot urine samples of Chinese yellow cattle

    International Nuclear Information System (INIS)

    Xing, Z.; Xi, W.B.; Mo, F.; Liu, J.W.; Yang, Y.F.; Chen, X.B.

    2004-01-01

    An experiment was conducted using 18 Chinese Yellow Cattle located in 5 farms to study how supplementation of fermentable energy to low quality straw-based rations would improve rumen microbial protein synthesis. Within each farm, the animals were fed on five diets. Diets 1-2 were typical rice straw + by-products used by farmers and were low in fermentable energy content; Diets 3- 5 were more balanced, containing a higher content of fermentable energy. Purine derivatives (PD) and creatinine in spot urine samples were measured. The results showed that the PD to creatinine ratio was significantly higher with Diets 3-5 than with Diets 1-2. Organic matter digestibility and thus organic matter intake was also higher with Diets 3-5 compared to Diets 1-2. The results indicted that the efficiency of microbial protein synthesis could be improved by balancing the diet. (author)

  19. Novel synthesis of nanocomposite for the extraction of Sildenafil Citrate (Viagra) from water and urine samples: Process screening and optimization.

    Science.gov (United States)

    Asfaram, Arash; Ghaedi, Mehrorang; Purkait, Mihir Kumar

    2017-09-01

    A sensitive analytical method is investigated to concentrate and determine trace level of Sildenafil Citrate (SLC) present in water and urine samples. The method is based on a sample treatment using dispersive solid-phase micro-extraction (DSPME) with laboratory-made Mn@ CuS/ZnS nanocomposite loaded on activated carbon (Mn@ CuS/ZnS-NCs-AC) as a sorbent for the target analyte. The efficiency was enhanced by ultrasound-assisted (UA) with dispersive nanocomposite solid-phase micro-extraction (UA-DNSPME). Four significant variables affecting SLC recovery like; pH, eluent volume, sonication time and adsorbent mass were selected by the Plackett-Burman design (PBD) experiments. These selected factors were optimized by the central composite design (CCD) to maximize extraction of SLC. The results exhibited that the optimum conditions for maximizing extraction of SLC were 6.0 pH, 300μL eluent (acetonitrile) volume, 10mg of adsorbent and 6min sonication time. Under optimized conditions, virtuous linearity of SLC was ranged from 30 to 4000ngmL -1 with R 2 of 0.99. The limit of detection (LOD) was 2.50ngmL -1 and the recoveries at two spiked levels were ranged from 97.37 to 103.21% with the relative standard deviation (RSD) less than 4.50% (n=15). The enhancement factor (EF) was 81.91. The results show that the combination UAE with DNSPME is a suitable method for the determination of SLC in water and urine samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Hydrophilic interaction chromatography combined with dispersive liquid-liquid microextraction as a preconcentration tool for the simultaneous determination of the panel of underivatized neurotransmitters in human urine samples.

    Science.gov (United States)

    Konieczna, Lucyna; Roszkowska, Anna; Niedźwiecki, Maciej; Bączek, Tomasz

    2016-01-29

    A simple and sensitive method using dispersive liquid-liquid microextraction (DLLME) followed by liquid chromatography coupled to mass spectrometry (LC-MS) with a hydrophilic interaction chromatography (HILIC) column was developed for the simultaneous determination of 13 compounds of different polarities, comprising monoamine neurotransmitters (dopamine, norepinephrine, epinephrine and serotonin) along with their respective precursors and metabolites, in human urine samples. The microextraction procedure was based on the fast injection of a mixture of ethanol (disperser solvent) and dichloromethane (extraction solvent) into a human urine sample, forming a cloudy solution in the Eppendorf tube. After centrifugation, the sedimented phase was collected and subsequently analyzed by LC-HILIC-MS in about 12min without a derivatization step. The separation was performed on an XBridge Amide™ BEH column 3.0×100mm, 3.5mm and the mobile phase consisted of phase A: 10mM ammonium formate buffer in water pH 3.0 and phase B: 10 mM ammonium formate buffer in acetonitrile, under gradient program elution. Tyrosine, tryptophan, 5-hydroxytryptophan, dopamine, epinephrine, norepinephrine, serotonin, 3-methoxytyramine, 5-hydroxyindole-3-acetic acid, 3,4-dihydroxy-l-phenylalanine and norvaline (internal standard) were detected in the positive ionization mode. While vanillylmandelic acid, homovanillic acid, 3,4-dihydroxyphenylacetic acid and 3,4-dihydroxybenzylamine (internal standard) were detected in the negative ionization mode. Parameters influencing DLLME and LC-HILIC-MS were investigated. Under the optimum conditions, the proposed method exhibited a low detection limit (5-10ngmL(-1)), and good linearity with R between 0.9991 and 0.9998. The recoveries in human urine samples were 99.0%±3.6%. for the 13 studied biogenic amines with intra- and inter-day RSDs of 0.24-9.55% and 0.31-10.0%, respectively. The developed DLLME-LC-MS method could be successfully applied for the

  1. Per- and polyfluoroalkyl substances in human serum and urine samples from a residentially exposed community.

    Science.gov (United States)

    Worley, Rachel Rogers; Moore, Susan McAfee; Tierney, Bruce C; Ye, Xiaoyun; Calafat, Antonia M; Campbell, Sean; Woudneh, Million B; Fisher, Jeffrey

    2017-09-01

    Per- and polyfluoroalkyl substances (PFAS) are considered chemicals of emerging concern, in part due to their environmental and biological persistence and the potential for widespread human exposure. In 2007, a PFAS manufacturer near Decatur, Alabama notified the United States Environmental Protection Agency (EPA) it had discharged PFAS into a wastewater treatment plant, resulting in environmental contamination and potential exposures to the local community. To characterize PFAS exposure over time, the Agency for Toxic Substances and Disease Registry (ATSDR) collected blood and urine samples from local residents. Eight PFAS were measured in serum in 2010 (n=153). Eleven PFAS were measured in serum, and five PFAS were measured in urine (n=45) from some of the same residents in 2016. Serum concentrations were compared to nationally representative data and change in serum concentration over time was evaluated. Biological half-lives were estimated for perfluorooctanoic acid (PFOA), perfluorooctane sulfonic acid (PFOS), and perfluorohexane sulfonic acid (PFHxS) using a one-compartment pharmacokinetic model. In 2010 and 2016, geometric mean PFOA and PFOS serum concentrations were elevated in participants compared to the general U.S. In 2016, the geometric mean PFHxS serum concentration was elevated compared to the general U.S. Geometric mean serum concentrations of PFOA, PFOS, and perfluorononanoic acid (PFNA) were significantly (p≤0.0001) lower (49%, 53%, and 58%, respectively) in 2016 compared to 2010. Half-lives for PFOA, PFOS, and PFHxS were estimated to be 3.9, 3.3, and 15.5years, respectively. Concentrations of PFOA in serum and urine were highly correlated (r=0.75) in males. Serum concentrations of some PFAS are decreasing in this residentially exposed community, but remain elevated compared to the U.S. general population. Published by Elsevier Ltd.

  2. Identification of AKB-48 and 5F-AKB-48 Metabolites in Authentic Human Urine Samples Using Human Liver Microsomes and Time of Flight Mass Spectrometry

    OpenAIRE

    Vikingsson, Svante; Josefsson, Martin; Green, Henrik

    2015-01-01

    The occurrence of structurally related synthetic cannabinoids makes the identification of unique markers of drug intake particularly challenging. The aim of this study was to identify unique and abundant metabolites of AKB-48 and 5F-AKB-48 for toxicological screening in urine. Investigations of authentic urine samples from forensic cases in combination with human liver microsome (HLM) experiments were used for identification of metabolites. HLM incubations of AKB-48 and 5F-AKB-48 along with 3...

  3. Method for Determination of Neptunium in Large-Sized Urine Samples Using Manganese Dioxide Coprecipitation and 242Pu as Yield Tracer

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2013-01-01

    A novel method for bioassay of large volumes of human urine samples using manganese dioxide coprecipitation for preconcentration was developed for rapid determination of 237Np. 242Pu was utilized as a nonisotopic tracer to monitor the chemical yield of 237Np. A sequential injection extraction chr...... and rapid analysis of neptunium contamination level for emergency preparedness....

  4. A competitive immunoassay for ultrasensitive detection of Hg{sup 2+} in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering

    Energy Technology Data Exchange (ETDEWEB)

    She, Pei; Chu, Yanxin [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Liu, Chunwei; Guo, Xun [OptoTrace (Suzhou) Technologies, Inc., STE 316, Building 4, No. 218, Xinghu Street, bioBAY, Suzhou Industrial Park, Suzhou 215123 (China); Zhao, Kang [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Li, Jianguo, E-mail: lijgsd@suda.edu.cn [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Du, Haijing; Zhang, Xiang [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Wang, Hong [OptoTrace (Suzhou) Technologies, Inc., STE 316, Building 4, No. 218, Xinghu Street, bioBAY, Suzhou Industrial Park, Suzhou 215123 (China); Deng, Anping, E-mail: denganping@suda.edu.cn [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China)

    2016-02-04

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg{sup 2+}. This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg{sup 2+} and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg{sup 2+}. The ICT was able to directly detect Hg{sup 2+} without complexing due to the specific recognition of the mAb with Hg{sup 2+}. The IC{sub 50} and limit of detection (LOD) of the assay for Hg{sup 2+} detection were 0.12 ng mL{sup −1} and 0.45 pg mL{sup −1}, respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg{sup 2+} were in range of 88.3–107.3% with the relative standard deviations (RSD) of 1.5–9.5% (n = 3). The proposed ICT was used for the detection of Hg{sup 2+} in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg{sup 2+} in environmental water samples and biological serum and urine samples. - Highlights: • The proposed ICT was able to directly detect Hg{sup 2+} without formation of Hg{sup 2+}-ligand complex. • The proposed ICT exhibited high sensitivity, specificity, stability, precision and accuracy for Hg{sup 2+} detection. • The proposed ICT was applicable for the detection of trace amount of Hg{sup 2+} in water, human serum and urine samples.

  5. Advantage of multiple spot urine collections for estimating daily sodium excretion: comparison with two 24-h urine collections as reference.

    Science.gov (United States)

    Uechi, Ken; Asakura, Keiko; Ri, Yui; Masayasu, Shizuko; Sasaki, Satoshi

    2016-02-01

    Several estimation methods for 24-h sodium excretion using spot urine sample have been reported, but accurate estimation at the individual level remains difficult. We aimed to clarify the most accurate method of estimating 24-h sodium excretion with different numbers of available spot urine samples. A total of 370 participants from throughout Japan collected multiple 24-h urine and spot urine samples independently. Participants were allocated randomly into a development and a validation dataset. Two estimation methods were established in the development dataset using the two 24-h sodium excretion samples as reference: the 'simple mean method' estimated by multiplying the sodium-creatinine ratio by predicted 24-h creatinine excretion, whereas the 'regression method' employed linear regression analysis. The accuracy of the two methods was examined by comparing the estimated means and concordance correlation coefficients (CCC) in the validation dataset. Mean sodium excretion by the simple mean method with three spot urine samples was closest to that by 24-h collection (difference: -1.62  mmol/day). CCC with the simple mean method increased with an increased number of spot urine samples at 0.20, 0.31, and 0.42 using one, two, and three samples, respectively. This method with three spot urine samples yielded higher CCC than the regression method (0.40). When only one spot urine sample was available for each study participant, CCC was higher with the regression method (0.36). The simple mean method with three spot urine samples yielded the most accurate estimates of sodium excretion. When only one spot urine sample was available, the regression method was preferable.

  6. Estimation of tritium activity in bioassay samples having chemiluminescence

    International Nuclear Information System (INIS)

    Dwivedi, R.K.; Manu, Kumar; Kumar, Vinay; Soni, Ashish; Kaushik, A.K.; Tiwari, S.K.; Gupta, Ashok

    2008-01-01

    Tritium is recognized as major internal dose contributor in PHWR type of reactors. Estimation of internal dose due to tritium is carried out by analyzing urine samples in liquid scintillation analyzer (LSA). Presence of residual biochemical species in urine samples of some individuals under medical administration shows significant amount of chemiluminescence. If appropriate care is not taken the results obtained by liquid scintillation counter may be mistaken as genuine uptake of tritium. The distillation method described in this paper is used at RAPS-3 and 4 to assess correct tritium uptake. (author)

  7. Antibiotic exposure in a low-income country: screening urine samples for presence of antibiotics and antibiotic resistance in coagulase negative staphylococcal contaminants.

    Directory of Open Access Journals (Sweden)

    Anne Mette Lerbech

    Full Text Available Development of antimicrobial resistance has been assigned to excess and misuse of antimicrobial agents. Staphylococci are part of the normal flora but are also potential pathogens that have become essentially resistant to many known antibiotics. Resistances in coagulase negative staphylococci (CoNS are suggested to evolve due to positive selective pressure following antibiotic treatment. This study investigated the presence of the nine most commonly used antimicrobial agents in human urine from outpatients in two hospitals in Ghana in relation to CoNS resistance. Urine and CoNS were sampled (n = 246 and n = 96 respectively from patients in two hospitals in Ghana. CoNS were identified using Gram staining, coagulase test, and MALDI-TOF/MS, and the antimicrobial susceptibility to 12 commonly used antimicrobials was determined by disk diffusion. Moreover an analytical method was developed for the determination of the nine most commonly used antimicrobial agents in Ghana by using solid-phase extraction in combination with HPLC-MS/MS using electron spray ionization. The highest frequency of resistance to CoNS was observed for penicillin V (98%, trimethoprim (67%, and tetracycline (63%. S. haemolyticus was the most common isolate (75%, followed by S. epidermidis (13% and S. hominis (6%. S. haemolyticus was also the species displaying the highest resistance prevalence (82%. 69% of the isolated CoNS were multiple drug resistant (≧ 4 antibiotics and 45% of the CoNS were methicillin resistant. Antimicrobial agents were detected in 64% of the analysed urine samples (n = 121 where the most frequently detected antimicrobials were ciprofloxacin (30%, trimethoprim (27%, and metronidazole (17%. The major findings of this study was that the prevalence of detected antimicrobials in urine was more frequent than the use reported by the patients and the prevalence of resistant S. haemolyticus was more frequent than other resistant CoNS species when antimicrobial

  8. Measurement of trace elements in liver biopsy samples from cattle

    NARCIS (Netherlands)

    Ouweltjes, W.; Zeeuw, de A.C.; Moen, A.; Counotte, G.H.M.

    2007-01-01

    Serum, plasma, or urine samples are usually used for the measurement of the trace elements copper, zinc, iron, selenium, because these samples are easy to obtain; however, these samples are not always appropriate. For example, it is not possible to measure molybdenum, the major antagonist of copper,

  9. Black Urine

    Directory of Open Access Journals (Sweden)

    Rahim Vakili

    2016-06-01

    Full Text Available A 2-year-old boy was born at term of healthy, non-consanguineous Iranian parents. His mother attended in the clinic with the history of sometimes discoloration of diapers after passing urine. She noticed that first at the age of one month with intensified in recent months. His Physical examination and growth parameters were normal. His mother denied taking any medication (sorbitol, nitrofurantoin, metronidazole, methocarbamol, sena and methyldopa (5. Qualitative urine examination showed dark black discoloration. By this history, alkaptonuria was the most clinical suspicious. A 24-hour-urine sample was collected and sent for quantitative measurements. The urine sample was highly positive for homogentisic acid and negative for porphyrin metabolites.

  10. Validation of the method for determination of plutonium isotopes in urine samples and its application in a nuclear facility at Otwock

    Directory of Open Access Journals (Sweden)

    Rzemek Katarzyna

    2015-03-01

    Full Text Available The studies aimed at determining low activities of alpha radioactive elements are widely recognized as essential for the human health, because of their high radiotoxicity in case of internal contamination. Some groups of workers of nuclear facility at Otwock are potentially exposed to contamination with plutonium isotopes. For this reason, the method for determination of plutonium isotopes has been introduced and validated in Radiation Protection Measurements Laboratory (LPD of the National Centre for Nuclear Research (NCBJ. In this method the plutonium is isolated from a sample by coprecipitation with phosphates and separated on a AG 1-X2 Resin. After electrodeposition, the sample is measured by alpha spectrometry. Validation was performed in order to assess parameters such as: selectivity, accuracy (trueness and precision and linearity of the method. The results of plutonium determination in urine samples of persons potentially exposed to internal contamination are presented in this work.

  11. A competitive immunoassay for ultrasensitive detection of Hg(2+) in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering.

    Science.gov (United States)

    She, Pei; Chu, Yanxin; Liu, Chunwei; Guo, Xun; Zhao, Kang; Li, Jianguo; Du, Haijing; Zhang, Xiang; Wang, Hong; Deng, Anping

    2016-02-04

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg(2+). This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg(2+) and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg(2+). The ICT was able to directly detect Hg(2+) without complexing due to the specific recognition of the mAb with Hg(2+). The IC50 and limit of detection (LOD) of the assay for Hg(2+) detection were 0.12 ng mL(-1) and 0.45 pg mL(-1), respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg(2+) were in range of 88.3-107.3% with the relative standard deviations (RSD) of 1.5-9.5% (n = 3). The proposed ICT was used for the detection of Hg(2+) in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg(2+) in environmental water samples and biological serum and urine samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Phase I metabolism of the recently emerged synthetic cannabinoid CUMYL-PEGACLONE and detection in human urine samples.

    Science.gov (United States)

    Mogler, Lukas; Wilde, Maurice; Huppertz, Laura M; Weinfurtner, Georg; Franz, Florian; Auwärter, Volker

    2018-05-01

    Indole-, indazole-, or azaindole-based synthetic cannabinoids (SCs), bearing a cumyl substituent are a widespread, recreationally used subgroup of new psychoactive substances (NPS). The latest cumyl-derivative, CUMYL-PEGACLONE, emerged in December 2016 on the German drug market. The substance features a novel γ-carboline core structure, which is most likely synthesized to bypass generic legislative approaches to control SCs by prohibiting distinct core structures. Using liquid chromatography-tandem mass spectrometry and liquid chromatography-high resolution mass spectrometry techniques, the main in vivo phase I metabolites of this new substance were detected. A pooled human liver microsome assay was applied to generate in vitro reference spectra of CUMYL-PEGACLONE phase I metabolites. Additionally, 30 urine samples were investigated leading to 22 in vivo metabolites. A metabolite mono-hydroxylated at the γ-carbolinone core system and a metabolite with an additional carbonyl group at the pentyl side chain were evaluated as highly specific and sensitive markers to proof CUMYL-PEGACLONE uptake. Moreover, 3 immunochemical assays commonly used for SC screening in urine were tested for their capability of detecting the new drug but failed due to insufficient cross-reactivity. Copyright © 2018 John Wiley & Sons, Ltd.

  13. Sample handling of clinical specimens for ultratrace element analysis

    International Nuclear Information System (INIS)

    Cornelis, R.

    1987-01-01

    Some simple logistics to an improved sample handling of clinical specimens are presented. This comprises clean room conditions, clean laboratory ware, ultra-pure reagents and good analytical practice. Sample handling procedures for blood, urine, soft tissues and pharmaceuticals are briefly discussed. (author) 26 refs

  14. The urine marker test

    DEFF Research Database (Denmark)

    Elbe, Anne-Marie; Jensen, Stine Nylandsted; Elsborg, Peter

    2016-01-01

    BACKGROUND: Urine sample collection for doping control tests is a key component of the World Anti-Doping Agency's fight against doping in sport. However, a substantial number of athletes experience difficulty when having to urinate under supervision. Furthermore, it cannot always be ensured...... that athletes are actually delivering their own urine. A method that can be used to alleviate the negative impact of a supervised urination procedure and which can also identify urine as coming from a specific athlete is the urine marker test. Monodisperse low molecular weight polyethylene glycols (PEGs......) are given orally prior to urination. Urine samples can be traced to the donor by analysis of the PEGs previously given. OBJECTIVE: The objective of this study was to investigate the use of the urine marker during urine doping control testing. METHODS: Two studies investigated athletes' acceptance...

  15. Detection of the diuretic hydrochlorothiazide in a doping control urine sample as the result of a non-steroidal anti-inflammatory drug (NSAID) tablet contamination.

    Science.gov (United States)

    Helmlin, Hans-Jörg; Mürner, André; Steiner, Samuel; Kamber, Matthias; Weber, Christina; Geyer, Hans; Guddat, Sven; Schänzer, Wilhelm; Thevis, Mario

    2016-10-01

    Hydrochlorothiazide (HCTZ, 6-chloro-3,4-dihydro-2H-1,2,4-benzothiadiazine-7-sulfonamide-1,1-dioxide) belongs to the class of diuretic agents that represent one of today's cornerstones of the treatment of hypertensive patients. In addition to its clinical relevance, HCTZ is prohibited in sports according to the regulations of the World Anti-Doping Agency (WADA) at all times and has frequently been detected in sports drug testing urine samples worldwide since its ban was introduced in 1988. Despite these facts, the adverse analytical finding concerning HCTZ in an in-competition routine doping control sample collected in December 2014 was further investigated, particularly motivated by the comparably low urinary concentration of the drug accounting for approximately 5ng/mL. The athlete in question did not declare the use of any nutritional supplement or medication other than the ingestion of a non-steroidal anti-inflammatory drug (NSAID) prior to competition. Hence, the drug (formulated as coated tablet) provided by the athlete as well as the corresponding retention sample of the manufacturer were analyzed. Noteworthy, both samples confirmed the presence of about 2μg of HCTZ per tablet. In order to further probe for the plausibility of the observed urinary HCTZ concentrations with the scenario of drug ingestion and subsequent doping control sample collection, administration studies with produced HCTZ-spiked placebo-tablets (2.5μg of HCTZ/tablet) were conducted. Urine specimens were collected prior to and after ingestion of the drug and subjected to routine doping control analytical procedures employing liquid chromatography/tandem mass spectrometry. While blank urine samples returned negative test results, post-administration specimens were found to contain HCTZ at concentrations of approximately 1-16ng/mL, which supported the athlete's inadvertent intake of HCTZ via contaminated NSAID tablets. Due to the substantial sensitivity of test methods employed today by

  16. Validation and Assessment of Three Methods to Estimate 24-h Urinary Sodium Excretion from Spot Urine Samples in High-Risk Elder Patients of Stroke from the Rural Areas of Shaanxi Province

    Directory of Open Access Journals (Sweden)

    Wenxia Ma

    2017-10-01

    Full Text Available Background: 24-h urine collection is regarded as the “gold standard” for monitoring sodium intake at the population level, but ensuring high quality urine samples is difficult to achieve. The Kawasaki, International Study of Sodium, Potassium, and Blood Pressure (INTERSALT and Tanaka methods have been used to estimate 24-h urinary sodium excretion from spot urine samples in some countries, but few studies have been performed to compare and validate these methods in the Chinese population. Objective: To compare and validate the Kawasaki, INTERSALT and Tanaka formulas in predicting 24-h urinary sodium excretion using spot urine samples in 365 high-risk elder patients of strokefrom the rural areas of Shaanxi province. Methods: Data were collected from a sub-sample of theSalt Substitute and Stroke Study. 365 high-risk elder patients of stroke from the rural areas of Shaanxi province participated and their spot and 24-h urine specimens were collected. The concentrations of sodium, potassium and creatinine in spot and 24-h urine samples wereanalysed. Estimated 24-h sodium excretion was predicted from spot urine concentration using the Kawasaki, INTERSALT, and Tanaka formulas. Pearson correlation coefficients and agreement by Bland-Altman method were computed for estimated and measured 24-h urinary sodium excretion. Results: The average 24-h urinary sodium excretion was 162.0 mmol/day, which representing a salt intake of 9.5 g/day. Three predictive equations had low correlation with the measured 24-h sodium excretion (r = 0.38, p < 0.01; ICC = 0.38, p < 0.01 for the Kawasaki; r = 0.35, p < 0.01; ICC = 0.31, p < 0.01 for the INTERSALT; r = 0.37, p < 0.01; ICC = 0.34, p < 0.01 for the Tanaka. Significant biases between estimated and measured 24-h sodium excretion were observed (all p < 0.01 for three methods. Among the three methods, the Kawasaki method was the least biased compared with the other two methods (mean bias: 31.90, 95% Cl: 23.84, 39

  17. Determination of toxic trace elements in body fluid reference samples

    International Nuclear Information System (INIS)

    Gills, T.E.; McClendon, L.T.; Maienthal, E.J.; Becker, D.A.; Durst, R.A.; LaFleur, P.D.

    1974-01-01

    The measurement of elemental concentration in body fluids has been widely used to give indication of exposures to certain toxic materials and/or a measure of body burden. To understand fully the toxicological effect of these trace elements on our physiological system, meaningful analytical data are required along with accurate standards or reference samples. The National Bureau of Standards has prepared for the National Institute for Occupational Safety and Health (NIOSH) a number of reference samples containing selected toxic trace elements in body fluids. The reference samples produced include mercury in urine at three concentration levels, five elements (Se, Cu, As, Ni and Cr) in freeze-dried urine at two levels, fluorine in freeze-dried urine at two levels and lead in blood at two concentration levels. These reference samples have been found to be extremely useful for the evaluation of field and laboratory analytical methods for the analysis of toxic trace elements. In particular the use of at least two calibration points (i.e., ''normal'' and ''elevated'' levels) for a given matrix provides a more positive calibration for most analytical techniques over the range of interest for occupational toxicological levels of exposure. (U.S.)

  18. A Modified Protocol with Improved Detection Rate for Mis-Matched Donor HLA from Low Quantities of DNA in Urine Samples from Kidney Graft Recipients.

    Directory of Open Access Journals (Sweden)

    Janette Kwok

    Full Text Available Urine from kidney transplant recipient has proven to be a viable source for donor DNA. However, an optimized protocol would be required to determine mis-matched donor HLA specificities in view of the scarcity of DNA obtained in some cases.In this study, fresh early morning urine specimens were obtained from 155 kidney transplant recipients with known donor HLA phenotype. DNA was extracted and typing of HLA-A, B and DRB1 loci by polymerase chain reaction-specific sequence primers was performed using tailor-made condition according to the concentration of extracted DNA.HLA typing of DNA extracted from urine revealed both recipient and donor HLA phenotypes, allowing the deduction of the unknown donor HLA and hence the degree of HLA mis-match. By adopting the modified procedures, mis-matched donor HLA phenotypes were successfully deduced in all of 35 tested urine samples at DNA quantities spanning the range of 620-24,000 ng.This urine-based method offers a promising and reliable non-invasive means for the identification of mis-matched donor HLA antigens in kidney transplant recipients with unknown donor HLA phenotype or otherwise inadequate donor information.

  19. Rapid method for direct identification of bacteria in urine and blood culture samples by matrix-assisted laser desorption ionization time-of-flight mass spectrometry: intact cell vs. extraction method.

    Science.gov (United States)

    Ferreira, L; Sánchez-Juanes, F; Muñoz-Bellido, J L; González-Buitrago, J M

    2011-07-01

    Matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) is a fast and reliable technology for the identification of microorganisms with proteomics approaches. Here, we compare an intact cell method and a protein extraction method before application on the MALDI plate for the direct identification of microorganisms in both urine and blood culture samples from clinical microbiology laboratories. The results show that the intact cell method provides excellent results for urine and is a good initial method for blood cultures. The extraction method complements the intact cell method, improving microorganism identification from blood culture. Thus, we consider that MALDI-TOF MS performed directly on urine and blood culture samples, with the protocols that we propose, is a suitable technique for microorganism identification, as compared with the routine methods used in the clinical microbiology laboratory. © 2010 The Authors. Clinical Microbiology and Infection © 2010 European Society of Clinical Microbiology and Infectious Diseases.

  20. Capillary Electrophoresis Hyphenated with Mass Spectrometry for Determination of Inflammatory Bowel Disease Drugs in Clinical Urine Samples

    Directory of Open Access Journals (Sweden)

    Katarína Maráková

    2017-11-01

    Full Text Available Azathioprine is the main thiopurine drug used in the treatment of immune-based inflammations of gastrointestinal tract. For the purpose of therapy control and optimization, effective and reliable analytical methods for a rapid drug monitoring in biological fluids are essential. Here, we developed a separation method based on the capillary electrophoresis (CE hyphenated with tandem mass spectrometry (MS/MS for the simultaneous determination of azathioprine and its selected metabolites (6-thioguanine, 6-mercaptopurine, and 6-methylmercaptopurine as well as other co-medicated drugs (mesalazine, prednisone, and allopurinol. The optimized CE-MS/MS conditions provided a very efficient and stable system for the separation and sensitive detection of these drugs in human urine matrices. The developed method was successfully applied for the assay of the targeted drugs and their selected metabolites in urine samples collected from patients suffering from inflammatory bowel disease (IBD and receiving azathioprine therapy. The developed CE-MS/MS method, due to its reliability, short analysis time, production of complex clinical profiles, and favorable performance parameters, evaluated according to FDA guidelines for bioanalytical method validation, is proposed for routine clinical laboratories to optimize thiopurine therapy, estimate enzymatic activity, and control patient compliance with medication and co-medication.

  1. Sample handling and chemical procedures for efficacious trace analysis of urine by neutron activation analysis

    International Nuclear Information System (INIS)

    Blotcky, A.J.; Rack, E.P.; Roman, F.R.

    1988-01-01

    Important for the determination of trace elements, ions, or compounds in urine by chemical neutron activation analysis is the optimization of sample handling, preirradiation chemistry, and radioassay procedures necessary for viable analysis. Each element, because of its natural abundance in the earth's crust and, hence, its potential for reagent and environmental contamination, requires specific procedures for storage, handling, and preirradiation chemistry. Radioassay techniques for radionuclides vary depending on their half-lives and decay characteristics. Described in this paper are optimized procedures for aluminum and selenium. While 28 Al (T 1/2 = 2.24 min) and 77m Se(T 1/2 = 17.4s) have short half-lives, their gamma-ray spectra are quite different. Aluminum-28 decays by a 1779-keV gamma and 77m Se by a 162-keV gamma. Unlike selenium, aluminum is a ubiquitous element in the environment requiring special handling to minimize contamination in all phases of its analytical determination

  2. Analytical artefacts in the speciation of arsenic in clinical samples

    International Nuclear Information System (INIS)

    Slejkovec, Zdenka; Falnoga, Ingrid; Goessler, Walter; Elteren, Johannes T. van; Raml, Reingard; Podgornik, Helena; Cernelc, Peter

    2008-01-01

    Urine and blood samples of cancer patients, treated with high doses of arsenic trioxide were analysed for arsenic species using HPLC-HGAFS and, in some cases, HPLC-ICPMS. Total arsenic was determined with either flow injection-HGAFS in urine or radiochemical neutron activation analysis in blood fractions (in serum/plasma, blood cells). The total arsenic concentrations (during prolonged, daily/weekly arsenic trioxide therapy) were in the μg mL -1 range for urine and in the ng g -1 range for blood fractions. The main arsenic species found in urine were As(III), MA and DMA and in blood As(V), MA and DMA. With proper sample preparation and storage of urine (no preservation agents/storage in liquid nitrogen) no analytical artefacts were observed and absence of significant amounts of alleged trivalent metabolites was proven. On the contrary, in blood samples a certain amount of arsenic can get lost in the speciation procedure what was especially noticeable for the blood cells although also plasma/serum gave rise to some disappearance of arsenic. The latter losses may be attributed to precipitation of As(III)-containing proteins/peptides during the methanol/water extraction procedure whereas the former losses were due to loss of specific As(III)-complexing proteins/peptides (e.g. cysteine, metallothionein, reduced GSH, ferritin) on the column (Hamilton PRP-X100) during the separation procedure. Contemporary analytical protocols are not able to completely avoid artefacts due to losses from the sampling to the detection stage so that it is recommended to be careful with the explanation of results, particularly regarding metabolic and pharmacokinetic interpretations, and always aim to compare the sum of species with the total arsenic concentration determined independently

  3. Stability of cannabinoids in urine in three storage temperatures.

    Science.gov (United States)

    Golding Fraga, S; Díaz-Flores Estévez, J; Díaz Romero, C

    1998-01-01

    Stability of cannabinoid compounds in urine samples were evaluated using several storage temperatures. Appreciable losses (> 22.4 percent) were observed in some urine samples, after being stored at room temperature for 10 days. Lower losses (8.1 percent) were observed when the urine samples were refrigerated for 4 weeks. The behavior of urine samples depended on the analyzed urine. This could be due to the different stability of the cannabinoids present in each urine sample. Important losses of 8.0 +/- 10.6, 15.8 +/- 4.2, and 19.6 +/- 6.7 percent were found when the urine samples were frozen during 40 days, 1 year, and 3 years, respectively. Average losses (> > 5 percent) can be observed after one day which could mainly be due to the decrease of the solubility of 11-nor-U9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) or adsorption process of cannabinoid molecules to the plastic storage containers.

  4. Liquid chromatography and ultra-performance liquid chromatography-mass spectrometry fingerprinting of human urine: sample stability under different handling and storage conditions for metabonomics studies.

    Science.gov (United States)

    Gika, Helen G; Theodoridis, Georgios A; Wilson, Ian D

    2008-05-02

    Typically following collection biological samples are kept in a freezer for periods ranging from a few days to several months before analysis. Experience has shown that in LC-MS-based metabonomics research the best analytical practice is to store samples as these are collected, complete the sample set and analyse it in a single run. However, this approach is prudent only if the samples stored in the refrigerator or in the freezer are stable. Another important issue is the stability of the samples following the freeze-thaw process. To investigate these matters urine samples were collected from 6 male volunteers and analysed by LC-MS and ultra-performance liquid chromatography (UPLC)-MS [in both positive and negative electrospray ionization (ESI)] on the day of collection or at intervals of up to 6 months storage at -20 degrees C and -80 degrees C. Other sets of these samples underwent a series of up to nine freeze-thaw cycles. The stability of samples kept at 4 degrees C in an autosampler for up to 6 days was also assessed, with clear differences appearing after 48h. Data was analysed using multivariate statistical analysis (principal component analysis). The results show that sample storage at both -20 and -80 degrees C appeared to ensure sample stability. Similarly up to nine freeze thaw cycles were without any apparent effect on the profile.

  5. Temporal variability in urinary phthalate metabolite excretion based on spot, morning, and 24-h urine samples: Considerations for epidemiological studies

    DEFF Research Database (Denmark)

    Frederiksen, Hanne; Kranich, Selma K.; Jørgensen, Niels

    2013-01-01

    of exposures for these two phthalates in population studies and hence an attenuation of the power to detect possible exposure-outcome associations. The only slightly higher ICCs for 24-h pools compared to first-morning and spot urine samples does not seem to justify the extra effort needed to collect 24-h......Urinary phthalate excretion is used as marker of phthalate exposure in epidemiological studies. Here we examine the reliability of urinary phthalate levels in exposure classification by comparing the inter- and intrasubject variation of urinary phthalate metabolite levels. Thirty-three young...

  6. Effects of diet composition on mutagenic activity in urine.

    Science.gov (United States)

    Ohara, Akihiro; Matsuhisa, Tsugio

    2004-01-01

    The effects of dietary habits on mutagenic activity in urine were investigated using the umu test based on the use of the genetically engineered bacteria Salmonella typhimurium TA 1535 pSK1002. Genotoxic effects in sample urine were detected by measuring the activation of the SOS response in the bacteria and recording the beta- galactosidase activity. Human subjects consisted of smokers and non-smokers. Urine from subjects who consumed fish showed the highest mutagenic activity, followed by the urine samples from subjects who ate pork or beef. Chicken induced a low level of mutagenic activity. When the subjects ate fried or roasted animal foods, the urine samples gave higher mutagenicity than the urine samples from the subject who consumed non-fried or non-roasted animal foods. When the subject ate vegetables along with a diet rich in animal foods, the activity in urine decreased. Herbs and spices gave the same tendency toward decline as vegetables. Non-smoker urine shower mutagenic activity than samples from smokers.

  7. Detection of gonococcal antigens in urine by radioimmunoassay

    International Nuclear Information System (INIS)

    Thornley, M.J.; Wilson, D.V.; Hormaeche, R.D. de; Coombs, R.R.A.; Oates, J.K.

    1979-01-01

    A method of detecting gonococcal antigens by solid-phase radioimmunoassay with radioactively labelled antibody is described. A specificity test has been developed that enables this method to be used to detect gonococcal antigens in urine sediments. When sediments from samples of urine from male patients with gonorrhoea were tested, 31 (74%) of 42 gave positive results, clearly distinguishing them from sediments from urine samples from men with non-specific urethritis, none of which was positive. Ten of 14 urine sediments from urine samples from women with gonorrhoea gave positive results, as did 3 of 18 sediments from urine samples from women patients without gonorrhoea.These experiments demonstrate that gonococcal antigens can be detected in urine by radioimmunoassay; the method could be useful in diagnosis if, after refinement, its sensitivity and specificity were to be increased. (author)

  8. Rapid and sensitive determination of nine bisphenol analogues, three amphenicol antibiotics, and six phthalate metabolites in human urine samples using UHPLC-MS/MS.

    Science.gov (United States)

    Yao, Yuan; Shao, Yijun; Zhan, Ming; Zou, Xiaoli; Qu, Weidong; Zhou, Ying

    2018-06-01

    Bisphenol analogues, amphenicol antibiotics, and phthalate have widely aroused public concerns due to their adverse effects on human health. In this study, a rapid and sensitive method for determination of nine bisphenol analogues, three amphenicol antibiotics, and six phthalate metabolites in the urine based on ultra-high-performance liquid chromatography coupled with triple quadrupole tandem mass spectrometry was developed and validated. The sample pretreatment condition on the base of mixed-mode anion-exchange (Oasis MAX) SPE was optimized to separate bisphenol analogues and amphenicol antibiotics from phthalate metabolites: the former were detected with a mobile phase of 0.1% ammonium water solution/methanol containing 0.1% ammonium water solution in negative mode, whereas the latter were determined with a mobile phase of 0.1% acetic acid solution/acetonitrile containing 0.1% acetic acid in negative mode. The limits of detection were less than 0.26 ng/mL for bisphenol analogues, 0.12 ng/mL for amphenicol antibiotics, and 0.14 ng/mL for phathalate metabolites. The recoveries of all target analytes in three fortification levels ranged from 72.02 to 117.64% with the relative standard deviations of no larger than 14.51%. The matrix effect was adjusted by isotopically labeled internal standards. This proposed method was successfully applied to analyze 40 actual urines and 13 out of 18 studied compounds were detected. Graphical abstract Simultaneous determination of nine bisphenol analogues, three amphenicol antibiotics, and six phthalate metabolites in human urine samples.

  9. Preconcentration and determination of heavy metals in water, sediment and biological samples

    Directory of Open Access Journals (Sweden)

    Shirkhanloo Hamid

    2011-01-01

    Full Text Available In this study, a simple, sensitive and accurate column preconcentration method was developed for the determination of Cd, Cu and Pb ions in river water, urine and sediment samples by flame atomic absorption spectrometry. The procedure is based on the retention of the analytes on a mixed cellulose ester membrane (MCEM column from buffered sample solutions and then their elution from the column with nitric acid. Several parameters, such as pH of the sample solution, volume of the sample and eluent and flow rates of the sample were evaluated. The effects of diverse ions on the preconcentration were also investigated. The recoveries were >95 %. The developed method was applied to the determination of trace metal ions in river water, urine and sediment samples, with satisfactory results. The 3δ detection limits for Cu, Pb and Cd were found to be 2, 3 and 0.2 μg dm−3, respectively. The presented procedure was successfully applied for determination of the copper, lead and cadmium contents in real samples, i.e., river water and biological samples.

  10. Ultralow-level measurement of organically-bound tritium in bioassay samples

    International Nuclear Information System (INIS)

    Kotzer, T.; Trivedi, A.; Waito, G.; Workman, W.

    1998-12-01

    An intercomparison study of urine samples having high levels (5 Bq·L -1 ) of organically-bound tritium (OBT) was conducted, in conjunction with the oxygen combustion-liquid scintillation counting (LSC) method, to evaluate the suitability and sensitivity of the 3 He-ingrowth mass spectrometry (MS) technique for OBT in bioassay samples. The study established that 3 He ingrowth-MS has the required sensitivity to measure ultralow levels of OBT-in-urine (∼0.1 Bq·L -1 ). Cumulative 24 h urine samples from a few members of the general population, living in the vicinity of the heavy-water research reactor facility at Chalk River Laboratories (CRL) at Chalk River, were collected and analyzed for tritiated water (HTO) and OBT. The participants were from Ottawa (200 km east), Deep River (10 km west) and an occasionally occupationally HTO-exposed worker at CRL. HTO-in-urine values were 6.5 Bq·L -1 for the Ottawa resident, 15.8 Bq·L -1 for the Deep River resident, and 1260 Bq·L -1 for the exposed worker. OBT-in-urine levels from these same individuals were 0.06 Bq·L -1 (Ottawa), 0.29 Bq·L -1 (Deep River), and 2.2 Bq·L -1 (exposed worker). With a model developed for calculating OBT dose fraction from the measured ratio of HTO to OBT in urine, we estimated that the dose arising from OBT in the body was about 26% of the total tritium dose for the Ottawa resident and 50% for the Deep River resident. The CRL individual had a 5% dose contribution from OBT, but had higher overall tritium dose due to frequent intakes of HTO. The study indicates that the bulk of the tritium dose to the population is the result of HTO intakes and not due to dietary intake of OBT. (author)

  11. Performance of Urinary Markers for Detection of Upper Tract Urothelial Carcinoma: Is Upper Tract Urine More Accurate than Urine from the Bladder?

    Directory of Open Access Journals (Sweden)

    Simone Bier

    2018-01-01

    Full Text Available Objectives. To assess the performance of urine markers determined in urine samples from the bladder compared to samples collected from the upper urinary tract (UUT for diagnosis of UUT urothelial carcinoma (UC. Patients and Methods. The study comprised 758 urine samples either collected from the bladder (n=373 or UUT (n=385. All patients underwent urethrocystoscopy and UUT imaging or ureterorenoscopy. Cytology, fluorescence in situ hybridization (FISH, immunocytology (uCyt+, and nuclear matrix protein 22 (NMP22 were performed. Results. UUT UC was diagnosed in 59 patients (19.1% (UUT urine and 27 patients (7.2% (bladder-derived urine. For UUT-derived samples, sensitivities for cytology, FISH, NMP22, and uCyt+ were 74.6, 79.0, 100.0, and 100.0, while specificities were 66.6, 50.7, 5.9, and 66.7%, respectively. In bladder-derived samples, sensitivities were 59.3, 52.9, 62.5, and 50.0% whereas specificities were 82.9, 85.0, 31.3, and 69.8%. In UUT-derived samples, concomitant bladder cancer led to increased false-positive rates of cytology and FISH. Conclusions. Urine markers determined in urine collected from the UUT exhibit better sensitivity but lower specificity compared to markers determined in bladder-derived urine. Concomitant or recent diagnosis of UC of the bladder can further influence markers determined in UUT urine.

  12. Determination of the pyrethroid insecticide metabolite 3-PBA in plasma and urine samples from farmer and consumer groups in northern Thailand

    Science.gov (United States)

    THIPHOM, SARUNYA; PRAPAMONTOL, TIPPAWAN; CHANTARA, SOMPORN; MANGKLABRUKS, AMPICA; SUPHAVILAI, CHAISUREE; AHN, KI CHANG; GEE, SHIRLEY J.; HAMMOCK, BRUCE D.

    2014-01-01

    In this study, the enzyme-linked immunosorbent assays (ELISA) were modified to detect 3-PBA in plasma (including the adducted form) and urine among a large group of consumers and farmers in an agricultural area. The samples were collected on the same day in the morning from 100 consumers (50 females, 50 males) and 100 farmers (50 females, 50 males) in the Fang district, Chiang Mai province, northern Thailand. The ELISA was very sensitive having an IC50 value of 26.7 and 15.3 ng/mL, a limit of quantitation of 5 and 2.5 ng/mL and a limit of detection of 1.08 and 1.94 ng/mL for plasma and urine, respectively. These methods had low (< 5%) intra- and inter-assay coefficients of variation. The extraction technique satisfactorily eliminated the matrix effect from samples before ELISA analysis, yielding good recoveries (85.9–99.4% and 87.3–98.0%, respectively). For the volunteer study, the detection rate for plasma 3-PBA was 24% in consumers and 42% in farmers, but the median and range values were similar (median 5.87 ng/mL, range 5.16–8.44 ng/mL in consumers and 6.27 ng/mL, range 4.29–9.57 ng/mL in farmers). The rate of detection in the urine was similar (76% and 69%, in consumers and in farmers), yet the median concentration was significantly higher in farmers (8.86 μg/g creatinine in consumers vs 16.1 μg/g creatinine in farmers) and the range also much wider in farmers (1.62–80.5 μg/g creatinine in consumers and 0.80–256.2 μg/g creatinine in farmers). There was no correlation between plasma 3-PBA and urinary 3-PBA concentrations in the study presumably because plasma 3-PBA is a measure of cumulative exposures while urinary 3-PBA reflects acute exposures. In addition, metabolism and excretion of pyrethroids varies by individual. Nevertheless, this study demonstrated that these volunteers were exposed to pyrethroids. To our knowledge, this is the first report that compared plasma 3-PBA and urinary 3-PBA in a large group of volunteers. The ELISA method

  13. Antibiotic Exposure in a Low-Income Country: Screening Urine Samples for Presence of Antibiotics and Antibiotic Resistance in Coagulase Negative Staphylococcal Contaminants

    DEFF Research Database (Denmark)

    Lerbeck, Anne Mette; Tersbøl, Britt Pinkowski; Styrishave, Bjarne

    2014-01-01

    for the determination of the nine most commonly used antimicrobial agents in Ghana by using solid-phase extraction in combination with HPLC-MS/MS using electron spray ionization. The highest frequency of resistance to CoNS was observed for penicillin V (98%), trimethoprim (67%), and tetracycline (63%). S. haemolyticus......596 respectively) from patients in two hospitals in Ghana. CoNS were identified using Gram staining, coagulase test, and MALDI-TOF/MS, and the antimicrobial susceptibility to 12 commonly used antimicrobials was determined by disk diffusion. Moreover an analytical method was developed...... agents were detected in 64% of the analysed urine samples (n5121) where the most frequently detected antimicrobials were ciprofloxacin (30%), trimethoprim (27%), and metronidazole (17%). The major findings of this study was that the prevalence of detected antimicrobials in urine was more frequent than...

  14. Substitution of human for horse urine disproves an accusation of doping*.

    Science.gov (United States)

    Díaz, Silvina; Kienast, Mariana E; Villegas-Castagnasso, Egle E; Pena, Natalia L; Manganare, Marcos M; Posik, Diego; Peral-García, Pilar; Giovambattista, Guillermo

    2008-09-01

    In order to detect switching and/or manipulation of samples, the owner of a stallion asked our lab to perform a DNA test on a positive doping urine sample. The objective was to compare the urine DNA profile versus blood and hair DNA profiles from the same stallion. At first, 10 microsatellite markers were investigated to determine the horse identity. No results were obtained when horse specific markers were typed in the urine sample. In order to confirm the species origin of this sample we analyzed the mitochondrial cytochrome b gene. This analysis from blood and hair samples produced reproducible and clear PCR-RFLP patterns and DNA sequence match with those expected for horse, while the urine sample results were coincident with human. These results allowed us to exclude the urine sample from the questioned stallion and determine its human species origin, confirming the manipulation of urine sample.

  15. Integrated preservation and sample clean up procedures for studying water ingestion by recreational swimmers via urinary biomarker determination.

    Science.gov (United States)

    Cantú, Ricardo; Shoemaker, Jody A; Kelty, Catherine A; Wymer, Larry J; Behymer, Thomas D; Dufour, Alfred P; Magnuson, Matthew L

    2017-08-22

    The use of cyanuric acid as a biomarker for ingestion of swimming pool water may lead to quantitative knowledge of the volume of water ingested during swimming, contributing to a better understanding of disease resulting from ingestion of environmental contaminants. When swimming pool water containing chlorinated cyanurates is inadvertently ingested, cyanuric acid is excreted quantitatively within 24 h as a urinary biomarker of ingestion. Because the volume of water ingested can be quantitatively estimated by calculation from the concentration of cyanuric acid in 24 h urine samples, a procedure for preservation, cleanup, and analysis of cyanuric acid was developed to meet the logistical demands of large scale studies. From a practical stand point, urine collected from swimmers cannot be analyzed immediately, given requirements of sample collection, shipping, handling, etc. Thus, to maintain quality control to allow confidence in the results, it is necessary to preserve the samples in a manner that ensures as quantitative analysis as possible. The preservation and clean-up of cyanuric acid in urine is complicated because typical approaches often are incompatible with the keto-enol tautomerization of cyanuric acid, interfering with cyanuric acid sample preparation, chromatography, and detection. Therefore, this paper presents a novel integration of sample preservation, clean-up, chromatography, and detection to determine cyanuric acid in 24 h urine samples. Fortification of urine with cyanuric acid (0.3-3.0 mg/L) demonstrated accuracy (86-93% recovery) and high reproducibility (RSD urine suggested sufficient cyanuric acid stability for sample collection procedures, while longer holding times suggested instability of the unpreserved urine. Preserved urine exhibited a loss of around 0.5% after 22 days at refrigerated storage conditions of 4 °C. Published by Elsevier B.V.

  16. A nanocomposite consisting of graphene oxide and Fe3O4 magnetic nanoparticles for the extraction of flavonoids from tea, wine and urine samples

    International Nuclear Information System (INIS)

    Wu, Jianrong; Xiao, Deli; Peng, Jun; Wang, Cuixia; Zhang, Chan; He, Jia; Zhao, Hongyan; He, Hua

    2015-01-01

    We describe a single-step solvothermal method for the preparation of nanocomposites consisting of graphene oxide and Fe 3 O 4 nanoparticles (GO/Fe 3 O 4 ). This material is shown to be useful as a magnetic sorbent for the extraction of flavonoids from green tea, red wine, and urine samples. The nanocomposite is taking advantage of the high surface area of GO and the magnetic phase separation feature of the magnetic sorbent. The nanocomposite is recyclable and was applied to the extraction of flavonoids prior to their determination by HPLC. The effects of amount of surfactant, pH value of the sample solution, extraction time, and desorption condition on the extraction efficiency, and the regeneration conditions were optimized. The limits of detection for luteolin, quercetin and kaempferol range from 0.2 to 0.5 ng∙ mL −1 in urine, from 3.0 to 6.0 ng∙mL −1 in green tea, and from 1.0 to 2.5 ng∙mL −1 in red wine. The recoveries are between 82.0 and 101.4 %, with relative standard deviations of <9.3 %. (author)

  17. Determination of uranium in clinical and environmental samples by FIAS-ICPMS

    International Nuclear Information System (INIS)

    Karpas, Z.; Lorber, A.; Halicz, L.; Gavrieli, I.

    1998-01-01

    Uranium may enter the human body through ingestion or inhalation. Ingestion of uranium compounds through the diet, mainly drinking water, is a common occurrence, as these compounds are present in the biosphere. Inhalation of uranium-containing particles is mainly an occupational safety problem, but may also take place in areas where uranium compounds are abundant. The uranium concentration in urine samples may serve as an indication of the total uranium body content. A method based on flow injection and inductively coupled plasma mass spectrometry (FIAS-ICPMS) was found to be most suitable for determination of uranium in clinical samples (urine and serum), environmental samples (seawater, wells and carbonate rocks) and in liquids consumed by humans (drinking water and commercial beverages). Some examples of the application of the FIAS-ICPMS method are reviewed and presented here

  18. The UK Biobank sample handling and storage validation studies.

    Science.gov (United States)

    Peakman, Tim C; Elliott, Paul

    2008-04-01

    and aims UK Biobank is a large prospective study in the United Kingdom to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. It involves the collection of blood and urine from 500 000 individuals aged between 40 and 69 years. How the samples are collected, processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. A series of validation studies was recommended to test the robustness of the draft sample handling and storage protocol. Samples of blood and urine were collected from 40 healthy volunteers and either processed immediately according to the protocol or maintained at specified temperatures (4 degrees C for all tubes with the exception of vacutainers containing acid citrate dextrose that were maintained at 18 degrees C) for 12, 24 or 36 h prior to processing. A further sample was maintained for 24 h at 4 degrees C, processed and the aliquots frozen at -80 degrees C for 20 days and then thawed under controlled conditions. The stability of the samples was compared for the different times in a wide variety of assays. The samples maintained at 4 degrees C were stable for at least 24 h after collection for a wide range of assays. Small but significant changes were observed in metabonomic studies in samples maintained at 4 degrees C for 36 h. There was no degradation of the samples for a range of biochemical assays after short-term freezing and thawing under controlled conditions. Whole blood maintained at 18 degrees C for 24 h in vacutainers containing acid citrate dextrose is suitable for viral immortalization techniques. The validation studies reported in this supplement provide justification for the sample handling and storage procedures adopted in the UK Biobank project.

  19. Accelerator mass spectrometry analysis of 14C-oxaliplatin concentrations in biological samples and 14C contents in biological samples and antineoplastic agents

    Science.gov (United States)

    Toyoguchi, Teiko; Kobayashi, Takeshi; Konno, Noboru; Shiraishi, Tadashi; Kato, Kazuhiro; Tokanai, Fuyuki

    2015-10-01

    Accelerator mass spectrometry (AMS) is expected to play an important role in microdose trials. In this study, we measured the 14C concentration in 14C-oxaliplatin-spiked serum, urine and supernatant of fecal homogenate samples in our Yamagata University (YU) - AMS system. The calibration curves of 14C concentration in serum, urine and supernatant of fecal homogenate were linear (the correlation coefficients were ⩾0.9893), and the precision and accuracy was within the acceptance criteria. To examine a 14C content of water in three vacuum blood collection tubes and a syringe were measured. 14C was not detected from water in these devices. The mean 14C content in urine samples of 6 healthy Japanese volunteers was 0.144 dpm/mL, and the intra-day fluctuation of 14C content in urine from a volunteer was little. The antineoplastic agents are administered to the patients in combination. Then, 14C contents of the antineoplastic agents were quantitated. 14C contents were different among 10 antineoplastic agents; 14C contents of paclitaxel injection and docetaxel hydrate injection were higher than those of the other injections. These results indicate that our quantitation method using YU-AMS system is suited for microdosing studies and that measurement of baseline and co-administered drugs might be necessary for the studies in low concentrations.

  20. Will Women Diagnosed with Breast Cancer Provide Biological Samples for Research Purposes?

    Directory of Open Access Journals (Sweden)

    Shelley A Harris

    Full Text Available Little is known about the response rates for biological sample donation and attitudes towards control recruitment, especially in younger women. The goals of this pilot study were to determine in women recently diagnosed with breast cancer, the proportion of cases willing to provide biological samples and for purposes of control recruitment, contact information for friends or colleagues.A population-based sample of breast cancer cases (n = 417, 25-74 years was recruited from the Ontario Cancer Registry in 2010 and self-administered questionnaires were completed to determine willingness to provide samples (spot or 24-hr urine, saliva, blood and contact information for friends/colleagues for control recruitment. Using Χ2 analyses of contingency tables we evaluated if these proportions varied by age group (<45 and 45+ and other factors such as ethnicity, education, income, body mass index (BMI, smoking status and alcohol consumption.Cases were willing to provide blood samples, by visiting a clinic (62% or by having a nurse visit the home (61%. Moreover, they would provide saliva (73%, and morning or 24-hr urine samples (66% and 52%. Younger cases (≤45 were 3 times (OR more likely more than older cases to agree to collect morning urine (95% CI: 1.15-8.35. Only 26% of cases indicated they would provide contact information of friends or work colleagues to act as controls. Educated cases were more likely to agree to provide samples, and cases who consumed alcohol were more willing to provide contact information. Ethnicity, income, BMI and smoking had little effect on response rates.Reasonable response rates for biological sample collection should be expected in future case controls studies in younger women, but other methods of control selection must be devised.

  1. Sample Preparation Report of the Fourth OPCW Confidence Building Exercise on Biomedical Sample Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Udey, R. N. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Corzett, T. H. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Alcaraz, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2014-07-03

    Following the successful completion of the 3rd biomedical confidence building exercise (February 2013 – March 2013), which included the analysis of plasma and urine samples spiked at low ppb levels as part of the exercise scenario, another confidence building exercise was targeted to be conducted in 2014. In this 4th exercise, it was desired to focus specifically on the analysis of plasma samples. The scenario was designed as an investigation of an alleged use of chemical weapons where plasma samples were collected, as plasma has been reported to contain CWA adducts which remain present in the human body for several weeks (Solano et al. 2008). In the 3rd exercise most participants used the fluoride regeneration method to analyze for the presence of nerve agents in plasma samples. For the 4th biomedical exercise it was decided to evaluate the analysis of human plasma samples for the presence/absence of the VX adducts and aged adducts to blood proteins (e.g., VX-butyrylcholinesterase (BuChE) and aged BuChE adducts using a pepsin digest technique to yield nonapeptides; or equivalent). As the aging of VX-BuChE adducts is relatively slow (t1/2 = 77 hr at 37 °C [Aurbek et al. 2009]), soman (GD), which ages much more quickly (t1/2 = 9 min at 37 °C [Masson et al. 2010]), was used to simulate an aged VX sample. Additional objectives of this exercise included having laboratories assess novel OP-adducted plasma sample preparation techniques and analytical instrumentation methodologies, as well as refining/designating the reporting formats for these new techniques.

  2. Pre-analytical and analytical validations and clinical applications of a miniaturized, simple and cost-effective solid phase extraction combined with LC-MS/MS for the simultaneous determination of catecholamines and metanephrines in spot urine samples.

    Science.gov (United States)

    Li, Xiaoguang Sunny; Li, Shu; Kellermann, Gottfried

    2016-10-01

    It remains a challenge to simultaneously quantify catecholamines and metanephrines in a simple, sensitive and cost-effective manner due to pre-analytical and analytical constraints. Herein, we describe such a method consisting of a miniaturized sample preparation and selective LC-MS/MS detection by the use of second morning spot urine samples. Ten microliters of second morning urine sample were subjected to solid phase extraction on an Oasis HLB microplate upon complexation with phenylboronic acid. The analytes were well-resolved on a Luna PFP column followed by tandem mass spectrometric detection. Full validation and suitability of spot urine sampling and biological variation were investigated. The extraction recovery and matrix effect are 74.1-97.3% and 84.1-119.0%, respectively. The linearity range is 2.5-500, 0.5-500, 2.5-1250, 2.5-1250 and 0.5-1250ng/mL for norepinephrine, epinephrine, dopamine, normetanephrine and metanephrine, respectively. The intra- and inter-assay imprecisions are ≤9.4% for spiked quality control samples, and the respective recoveries are 97.2-112.5% and 95.9-104.0%. The Deming regression slope is 0.90-1.08, and the mean Bland-Altman percentage difference is from -3.29 to 11.85 between a published and proposed method (n=50). A correlation observed for the spot and 24h urine collections is significant (n=20, p<0.0001, r: 0.84-0.95, slope: 0.61-0.98). No statistical differences are found in day-to-day biological variability (n=20). Reference intervals are established for an apparently healthy population (n=88). The developed method, being practical, sensitive, reliable and cost-effective, is expected to set a new stage for routine testing, basic research and clinical applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Direct assay for urine cortisol with cortisol kit TFB

    Energy Technology Data Exchange (ETDEWEB)

    Manaka, Yukiko; Watanabe, Michiko; Hosoya, Takaaki [Yamagata Univ. (Japan). Hospital

    2002-05-01

    We examined Cortisol Kit TFB for direct assay of urine cortisol. And the multiplication by dilution factor of urine cortisol values in this kit was examined. The coefficient of correlation of cortisol levels (46 urine samples) between Cortisol Kit TFB and Chemilumi ACS-Cortisol II, which is another kit for direct assay of urine cortisol, was r=0.858, y=1.86x+38.2 (p<0.001). There were differences between the both cortisol levels of each urine sample in spite of the good coefficient of correlation. The urine cortisol values obtained from the standard curve in addition of 50 {mu}l of zero standard were 50-80% of the values obtained from the standard curve in the package insert. These results suggest that the specificity of the antibodies of both direct assay kits for urine cortisol may be different each other, and the multiplication by 1.09, the dilution factor due to the addition of zero standard to only urine sample, is unnecessary although it is indispensable for urine samples to add zero standard. Cortisol Kit TFB was very convenient for its easy assay procedure and short incubation. (author)

  4. Direct assay for urine cortisol with cortisol kit TFB

    International Nuclear Information System (INIS)

    Manaka, Yukiko; Watanabe, Michiko; Hosoya, Takaaki

    2002-01-01

    We examined Cortisol Kit TFB for direct assay of urine cortisol. And the multiplication by dilution factor of urine cortisol values in this kit was examined. The coefficient of correlation of cortisol levels (46 urine samples) between Cortisol Kit TFB and Chemilumi ACS-Cortisol II, which is another kit for direct assay of urine cortisol, was r=0.858, y=1.86x+38.2 (p<0.001). There were differences between the both cortisol levels of each urine sample in spite of the good coefficient of correlation. The urine cortisol values obtained from the standard curve in addition of 50 μl of zero standard were 50-80% of the values obtained from the standard curve in the package insert. These results suggest that the specificity of the antibodies of both direct assay kits for urine cortisol may be different each other, and the multiplication by 1.09, the dilution factor due to the addition of zero standard to only urine sample, is unnecessary although it is indispensable for urine samples to add zero standard. Cortisol Kit TFB was very convenient for its easy assay procedure and short incubation. (author)

  5. Development of rapid urine analysis method for uranium

    Energy Technology Data Exchange (ETDEWEB)

    Kuwabara, J.; Noguchi, H. [Japan Atomic Energy Research Institute, Tokai, Ibaraki (Japan)

    2000-05-01

    ICP-MS has begun to spread in the field of individual monitoring for internal exposure as a very effective machine for uranium analysis. Although the ICP-MS has very high sensitivity, it requires longer time than conventional analysis, such as fluorescence analysis, because it is necessary to remove matrix from a urine sample sufficiently. To shorten time required for the urine bioassay by ICP-MS, a rapid uranium analysis method using the ICP-MS connected with a flow injection system was developed. Since this method does not involve chemical separation steps, the time required is equivalent to the conventional analysis. A measurement test was carried out using 10 urine solutions prepared from a urine sample. Required volume of urine solution is 5 ml. Main chemical treatment is only the digestion with 5 ml of nitric acid using a microwave oven to decompose organic matter and to dissolve suspended or precipitated matter. The microwave oven can digest 10 samples at once within an hour. Volume of digested sample solution was adjusted to 10 ml. The prepared sample solutions were directly introduced to the ICP-MS without any chemical separation procedure. The ICP-MS was connected with a flow injection system and an auto sampler. The flow injection system can minimize the matrix effects caused from salt dissolved in high matrix solution, such as non chemical separated urine sample, because it can introduce micro volume of sample solution into the ICP-MS. The ICP-MS detected uranium within 2 min/sample using the auto sampler. The 10 solutions prepared from a urine sample showed an average of 7.5 ng/l of uranium concentration in urine with 10 % standard deviation. A detection limit is about 1 ng/l. The total time required was less than 4 hours for 10 sample analysis. In the series of measurement, any memory effect was not observed. The present analysis method using the ICP-MS equipped with the flow injection system demonstrated that the shortening of time required on high

  6. Development of rapid urine analysis method for uranium

    International Nuclear Information System (INIS)

    Kuwabara, J.; Noguchi, H.

    2000-01-01

    ICP-MS has begun to spread in the field of individual monitoring for internal exposure as a very effective machine for uranium analysis. Although the ICP-MS has very high sensitivity, it requires longer time than conventional analysis, such as fluorescence analysis, because it is necessary to remove matrix from a urine sample sufficiently. To shorten time required for the urine bioassay by ICP-MS, a rapid uranium analysis method using the ICP-MS connected with a flow injection system was developed. Since this method does not involve chemical separation steps, the time required is equivalent to the conventional analysis. A measurement test was carried out using 10 urine solutions prepared from a urine sample. Required volume of urine solution is 5 ml. Main chemical treatment is only the digestion with 5 ml of nitric acid using a microwave oven to decompose organic matter and to dissolve suspended or precipitated matter. The microwave oven can digest 10 samples at once within an hour. Volume of digested sample solution was adjusted to 10 ml. The prepared sample solutions were directly introduced to the ICP-MS without any chemical separation procedure. The ICP-MS was connected with a flow injection system and an auto sampler. The flow injection system can minimize the matrix effects caused from salt dissolved in high matrix solution, such as non chemical separated urine sample, because it can introduce micro volume of sample solution into the ICP-MS. The ICP-MS detected uranium within 2 min/sample using the auto sampler. The 10 solutions prepared from a urine sample showed an average of 7.5 ng/l of uranium concentration in urine with 10 % standard deviation. A detection limit is about 1 ng/l. The total time required was less than 4 hours for 10 sample analysis. In the series of measurement, any memory effect was not observed. The present analysis method using the ICP-MS equipped with the flow injection system demonstrated that the shortening of time required on high

  7. Sample preparation automation for dosing plutonium in urine

    International Nuclear Information System (INIS)

    Jeanmaire, Lucien; Ballada, Jean; Ridelle Berger, Ariane

    1969-06-01

    After having indicated that dosing urinary plutonium by using the Henry technique can be divided into three stages (plutonium concentration by precipitation, passing the solution on an anionic resin column and plutonium elution, and eluate evaporation to obtain a source of which the radioactivity is measured), and recalled that the automation of the second stage has been reported in another document, this document describes the automation of the first stage, i.e. obtaining from urine a residue containing the plutonium, and sufficiently mineralized to be analyzed by means of ion exchanging resins. Two techniques are proposed, leading to slightly different devices. The different operations to be performed are indicated. The different components of the apparatus are described: beakers, hot plate stirrers, reagent circuits, a system for supernatant suction, and a control-command circuit. The operation and use are then described, and results are given

  8. New sample preparation method based on task-specific ionic liquids for extraction and determination of copper in urine and wastewater.

    Science.gov (United States)

    Trtić-Petrović, Tatjana; Dimitrijević, Aleksandra; Zdolšek, Nikola; Đorđević, Jelena; Tot, Aleksandar; Vraneš, Milan; Gadžurić, Slobodan

    2018-01-01

    In this study, four hydrophilic ionic liquids (ILs) containing 1-alkyl-3-methylimidazolim cation and either salicylate or chloride anions were synthetized and studied as new task-specific ionic liquids (TSILs) suitable for aqueous biphasic system (ABS) formation and selective one-step extraction of copper(II). TSILs are designed so that the anion is responsible for forming the complex with metal(II) and preventing hydrolysis of metal cations at very strong alkaline pH, whereas the cation is responsible for selective extraction of metal(II)-salicylate complexes. It was found that 1-butyl-3-methylimidazolium salicylate could be used for selective extraction of Cu(II) in the presence of Zn(II), Cd(II), and Pb(II) at very alkaline solution without metal hydroxide formation. It was assumed that formation of metal(II)-salicylate complexes prevents the hydrolysis of the metal ions in alkaline solutions. The determined stability constants for Cu(II)-salicylate complexes, where salicylate was derived from different ionic liquids, indicated that there was no significant influence of the cation of the ionic liquid on the stability of the complexes. The ABS based on 1-butyl-3-methylimidazolium salicylate has been applied as the sample preparation step prior to voltammetric determination of Cu(II). The effect of volume of aqueous sample and IL and extraction time were investigated and optimum extraction conditions were determined. The obtained detection limits were 8 ng dm -3 . The optimized method was applied for the determination of Cu(II) in tap water, wastewater, and urine. The study indicated that application of the ABS based on 1-butyl-3-methylimidazolium salicylate ionic liquid could be successfully applied as the sample preparation method for the determination of Cu(II) from various environmental samples. Graphical abstract Aqueous biphasic system based on task-specific ionic liquid as a sample pretreatment for selective determination of Cu(II) in biological and

  9. Self-Collected versus Clinician-Collected Sampling for Chlamydia and Gonorrhea Screening: A Systemic Review and Meta-Analysis

    Science.gov (United States)

    Lunny, Carole; Taylor, Darlene; Hoang, Linda; Wong, Tom; Gilbert, Mark; Lester, Richard; Krajden, Mel; Ogilvie, Gina

    2015-01-01

    Background The increases in STI rates since the late 1990s in Canada have occurred despite widespread primary care and targeted public health programs and in the setting of universal health care. More innovative interventions are required that would eliminate barriers to STI testing such as internet-based or mail-in home and community service testing for patients that are hard to reach, who refuse to go for clinician-based testing, or who decline an examination. Jurisdictions such as New Zealand and some American states currently use self-collected sampling, but without the required evidence to determine whether self-collected specimens are as accurate as clinician-collected specimens in terms of chlamydia and gonorrhea diagnostic accuracy. The objective of the review is to compare self-collected vaginal, urine, pharyngeal and rectal samples to our reference standard - clinician-collected cervical, urethral, pharyngeal and rectal sampling techniques to identify a positive specimen using nucleic acid amplification test assays. Methods The hierarchical summary receiver operating characteristic and the fixed effect models were used to assess the accuracy of comparable specimens that were collected by patients compared to clinicians. Sensitivity and specificity estimates with 95% confidence intervals (CI) were reported as our main outcome measures. Findings We included 21 studies based on over 6100 paired samples. Fourteen included studies examined chlamydia only, 6 compared both gonorrhea and chlamydia separately in the same study, and one examined gonorrhea. The six chlamydia studies comparing self-collection by vaginal swab to a clinician-collected cervical swab had the highest sensitivity (92%, 95% CI 87-95) and specificity (98%, 95% CI 97-99), compared to other specimen-types (urine/urethra or urine/cervix). Six studies compared urine self-samples to urethra clinician-collected samples in males and produced a sensitivity of 88% (95% CI 83-93) and a specificity of

  10. Determination of U, Th and Nb by ICP-MS in biological samples from a group non-occupationally exposed persons

    International Nuclear Information System (INIS)

    Santos, Maristela S.; Juliao, Ligia; Fernandes, Paulo Cesar; Melo, Dunstana; Godoy, Maria Luiza Duarte Pinto; Azeredo, Adelaide

    2001-01-01

    In order to have a good intake assessment for workers, by in vitro bioassay, appropriate methods to determine trace concentrations in urine and feces samples are required. Since the concentration of the radionuclides in the excretion samples of the workers shall be compared to the ones in the excretion samples of the members of the public. The adoption of this procedure is need to evaluate the contribution of the intake through diet ingestion or inhalation of particles in high background radiation areas, which can result in an increasing of the concentration of radionuclides in urine and feces samples due to environmental exposure independent of the occupational exposure. In Brazil, the radionuclides from the uranium and thorium series can be found associated to the ores. In order to carry out an evaluation of the internal contamination in workers from mine industry, specially niobium mine, the optimization of the methodology of the urine and feces sample preparation for determination of U, Th e Nb content using ICP-MS (Inductively Coupled Plasma - Mass Spectrometer) was need. For the feces sample preparation, the sample ash (400 deg C) was the first step, followed by the addition of the nitric, hydrofluoric and perchloric suprapur acids in PTFE recipient covered. The residue was dissolved with 2% nitric acid. For the urine samples, 1-ml aliquot was diluted in 2% nitric acid. A total of 23 feces samples and 25 urine samples from a group of inhabitants of Rio de Janeiro city, including children and adults, were analyzed. The results will be used as reference values in studies of evaluation of intake due to occupational exposure in Brazil. (author)

  11. High-resolution gel electrophoresis and sodium dodecyl sulphate-agarose gel electrophoresis on urine samples for qualitative analysis of proteinuria in dogs.

    Science.gov (United States)

    Giori, Luca; Tricomi, Flavia Marcella; Zatelli, Andrea; Roura, Xavier; Paltrinieri, Saverio

    2011-07-01

    The aims of the current study were to assess whether sodium dodecyl sulphate-agarose gel electrophoresis (SDS-AGE) and high-resolution electrophoresis (HRE) can identify dogs with a urinary protein-to-creatinine ratio (UPC ratio) >0.2 and whether HRE can provide preliminary information about the type of proteinuria, using SDS-AGE as a reference method. HRE and SDS-AGE were conducted on 87 urine samples classified according to the International Renal Interest Society as non-proteinuric (NP; UPC ratio: 0.51; 40/87). SDS-AGE and HRE were positive in 14 out of 32 and 3 out of 32 NP samples and in 52 out of 55 and 40 out of 55 samples with a UPC ratio >0.20, respectively. The concordance between HRE or SDS and UPC ratio was comparable (κ = 0.59; κ = 0.55). However, specificity (90%) and positive likelihood ratio (7.76) were higher for HRE than for SDS-AGE (56% and 2.16) while sensitivity was lower (73% vs. 94%). The analysis of HRE results revealed that a percentage of albumin >41.4% and an albumin/α(1)-globulin ratio (alb/α(1) ratio) >1.46 can identify samples classified by SDS-AGE as affected by glomerular proteinuria while a percentage of α(1)-globulin >40.8% and an alb/α(1) ratio HRE could misclassify samples with a UPC ratio higher or lower than 0.20. Therefore, UPC ratio must always be determined before conducting these tests. The percentage of albumin and α(1)-globulin or the alb/α(1) ratio determined by HRE can provide preliminary information about the origin of proteinuria.

  12. Phase I metabolism of the carbazole derived synthetic cannabinoids EG-018, EG-2201 and MDMB-CHMCZCA and detection in human urine samples.

    Science.gov (United States)

    Mogler, Lukas; Franz, Florian; Wilde, Maurice; Huppertz, Laura M; Halter, Sebastian; Angerer, Verena; Moosmann, Bjoern; Auwärter, Volker

    2018-05-04

    Synthetic cannabinoids (SCs) are a structurally diverse class of new psychoactive substances. Most SCs used for recreational purposes are based on indole or indazole core structures. EG-018 (naphthalen-1-yl(9-pentyl-9H-carbazol-3-yl)methanone), EG-2201 ((9-(5-fluoropentyl)-9H-carbazol-3-yl)(naphthalen-1-yl)methanone) and MDMB-CHMCZCA (methyl 2-(9-(cyclohexylmethyl)-9H-carbazole-3-carboxamido)-3,3-dimethylbutanoate) are three representatives of a structural subclass of SCs, characterized by a carbazole core system. In vitro and in vivo phase I metabolism studies were conducted to identify the most suitable metabolites for the detection of these substances in urine screening. Detection and characterization of metabolites were performed by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) and liquid chromatography-electrospray ionization-quadrupole time-of-flight mass spectrometry (LC-ESI-QToF-MS). Eleven in vivo metabolites were detected in urine samples positive for metabolites of EG-018 (n=8). A hydroxypentyl metabolite, most probably the 4-hydroxypentyl isomer, and an N-dealkylated metabolite mono-hydroxylated at the carbazole core system were most abundant. In vitro studies of EG-018 and EG-2201 indicated that oxidative defluorination of the 5-fluoropentyl side chain of EG-2201 as well as dealkylation led to common metabolites with EG-018. This has to be taken into account for interpretation of analytical findings. A differentiation between EG-018 and EG-2201 (n=1) uptake is possible by the detection of compound-specific in vivo phase I metabolites evaluated in this study. Out of 30 metabolites detected in urine samples of MDMB-CHMCZCA users (n=20), one metabolite mono-hydroxylated at the cyclohexyl methyl tail is considered the most suitable compound-specific consumption marker while a biotransformation product of mono-hydroxylation in combination with hydrolysis of the terminal methyl ester function provides best sensitivity

  13. Performance of Copan WASP for Routine Urine Microbiology

    Science.gov (United States)

    Quiblier, Chantal; Jetter, Marion; Rominski, Mark; Mouttet, Forouhar; Böttger, Erik C.; Keller, Peter M.

    2015-01-01

    This study compared a manual workup of urine clinical samples with fully automated WASPLab processing. As a first step, two different inocula (1 and 10 μl) and different streaking patterns were compared using WASP and InoqulA BT instrumentation. Significantly more single colonies were produced with the10-μl inoculum than with the 1-μl inoculum, and automated streaking yielded significantly more single colonies than manual streaking on whole plates (P < 0.001). In a second step, 379 clinical urine samples were evaluated using WASP and the manual workup. Average numbers of detected morphologies, recovered species, and CFUs per milliliter of all 379 urine samples showed excellent agreement between WASPLab and the manual workup. The percentage of urine samples clinically categorized as positive or negative did not differ between the automated and manual workflow, but within the positive samples, automated processing by WASPLab resulted in the detection of more potential pathogens. In summary, the present study demonstrates that (i) the streaking pattern, i.e., primarily the number of zigzags/length of streaking lines, is critical for optimizing the number of single colonies yielded from primary cultures of urine samples; (ii) automated streaking by the WASP instrument is superior to manual streaking regarding the number of single colonies yielded (for 32.2% of the samples); and (iii) automated streaking leads to higher numbers of detected morphologies (for 47.5% of the samples), species (for 17.4% of the samples), and pathogens (for 3.4% of the samples). The results of this study point to an improved quality of microbiological analyses and laboratory reports when using automated sample processing by WASP and WASPLab. PMID:26677255

  14. Development of a radioimmunoassay for the determination of buprenorphine in biological samples

    International Nuclear Information System (INIS)

    Debrabandere, L.; Boven, M. Van; Daenens, P.

    1993-01-01

    The development of a specific and sensitive radioimmunoassay for the detection of buprenorphine in urine samples is described. With minor adjustments, the assay was also applied to the analysis for buprenorphine in plasma samples. The 2-diazobenzoic acid derivative of buprenorphine has been prepared as a hapten. The immunization of rabbits with the hapten-bovine serum albumin conjugate resulted in the production of antibodies, which cross-reacted with N-dealkylbuprenophine up to about the 90% level. The antibodies showed very low cross-reactivities with the 3-O-glucuronides and with the structural analogue etorphine. The assay was mainly used to prescreen for buprenorphine in urine samples of persons suspected of Temgesic misuse and to determine buprenorphine in plasma samples. A linear calibration graph for buprenorphine was obtained after logit-log regression. The spiking recovery study showed a linear regression. Intra-and inter-assay relative standard deviations were -1 (Student's t-distribution, p 0.01, degrees of freedom = 8). (Author)

  15. Application of XRF and AAS for the elemental analysis of biological samples as monitors to occupational exposure

    International Nuclear Information System (INIS)

    Abdelrahman, Wafa Salih

    1999-12-01

    In the present study, hair and urine samples were collected from selected group of workers in industrial areas, and control group was collected from individuals resident far from contaminated areas. Air samples were collected form indoors atmosphere of these industries. Sudan Mint Company and Mirghani workshop are selected as a possible contaminated cities in Khartoum and Omdurman cities. X-ray fluorescence and atomic absorption techniques were applied to the analysis of the biological and air samples. AXIL computer program was used for fitting the collected spectra. The concentration of calcium, chromium, iron, cobalt, nickel, copper, zinc, bromine, and lead were evaluated. The result revealed that zinc and copper showed highest concentration in hair and air samples, while zinc was not detected in urine. In Mirghani workshop calcium, chromium, iron and zinc shows the highest values in air and hair samples also, zinc was not detected in urine. The correlation between the elemental content of the biological and environmental samples confirm that these elements can reach to the human body.(Author)

  16. Characterization of pesticide exposure in a sample of pregnant women in Ecuador

    Science.gov (United States)

    Handal, Alexis J.; Hund, Lauren; Páez, Maritza; Bear, Samantha; Greenberg, Carolyn; Fenske, Richard A.; Barr, Dana Boyd

    2015-01-01

    Background Few studies have detailed the prenatal pesticide exposure levels of women employed in or residing near large-scale agricultural industries. This study reports pesticide metabolite levels during and shortly after pregnancy in a pilot study of workers in Ecuador. Methods Urine samples were collected for 16 rose workers and 10 non-agricultural workers enrolled into the study in early pregnancy. We measured six nonspecific organophosphate dialkylphosphate (DAP) pesticide metabolites, two alkylenebis-dithiocarbamate pesticide metabolites (ethylene thiourea [ETU] and propylene thiourea [PTU]), 3,5,6-trichloro-2-pyridinol [TCPy], malathion dicarboxylic acid, and two pyrethroid metabolites (2,2-dimethylcyclopropanecarboxylic acid and 3-phenooxybenzoic acid). Results We collected 141 urine samples (mean: 5.4 per woman). We observed high detection frequencies for five DAP metabolites and ETU, PTU, and TCPy. We report elevated levels of ETU in the entire sample (median 4.24 ng/mL, IQR 2.23, 7.18), suggesting other possible non-occupational pathways of exposure. We found no statistical differences in pesticide levels by current employment status, though the highest pesticide levels were among rose workers. We observed within-woman correlation in TCPy and PTU levels, but not in ETU or DAP levels. Conclusions The present study is the first to characterize prenatal pesticide exposure levels among working women in Ecuador. Limitations include a small sample size and use of a convenience sample. Strengths include a longitudinal design and multiple urine samples per woman. Results provide an initial characterization of prenatal pesticide exposure levels and how these levels vary over pregnancy in a community impacted by agricultural industry and will inform further studies in the region. PMID:26311023

  17. Analytical investigations of toxic p-phenylenediamine (PPD) levels in clinical urine samples with special focus on MALDI-MS/MS.

    Science.gov (United States)

    Hooff, Gero P; van Huizen, Nick A; Meesters, Roland J W; Zijlstra, Eduard E; Abdelraheem, Mohamed; Abdelraheem, Waleed; Hamdouk, Mohamed; Lindemans, Jan; Luider, Theo M

    2011-01-01

    Para-phenylenediamine (PPD) is a common chromophoric ingredient in oxidative hair-dyes. In some African countries like Sudan, Egypt and Morocco but also in India this chemical is used alone or in combination with colouring extracts like Henna for dyeing of the hair or the skin. Excessive dermal exposure to PPD mainly leads to the N-mono- and N,N'-diacetylated products (MAPPD, DAPPD) by N-acetyltransferase 1 and 2 (NAT1 and 2) catalyzed reactions. Metabolites and PPD are mainly excreted via renal clearance. Despite a low risk of intoxication when used in due form, there are numerous cases of acute intoxication in those countries every year. At the ENT Hospital - Khartoum (Sudan) alone more than 300 cases are reported every year (~10% fatal), mostly caused by either an accidental or intended (suicidal) high systemic exposure to pure PPD. Intoxication leads to a severe clinical syndrome including laryngeal edema, rhabdomyolysis and subsequent renal failure, neurotoxicity and acute toxic hepatitis. To date, there is no defined clinical treatment or antidote available and treatment is largely supportive. Herein, we show the development of a quick on-site identification assay to facilitate differential diagnosis in the clinic and, more importantly, the implementation of an advanced analytical platform for future in-depth investigations of PPD intoxication and metabolism is described. The current work shows a sensitive (~25 µM) wet chemistry assay, a validated MALDI-MS/MS and HPLC-UV assay for the determination of PPD and its metabolites in human urine. We show the feasibility of the methods for measuring PPD over a range of 50-1000 µM. The validation criteria included linearity, lower limit of quantification (LLOQ), accuracy and precision, recovery and stability. Finally, PPD concentrations were determined in clinical urine samples of cases of acute intoxication and the applied technique was expanded to identify MAPPD and DAPPD in the identical samples.

  18. Molecularly imprinted polymeric stir bar: Preparation and application for the determination of naftopidil in plasma and urine samples.

    Science.gov (United States)

    Peng, Jun; Xiao, Deli; He, Hua; Zhao, Hongyan; Wang, Cuixia; Shi, Tian; Shi, Kexin

    2016-01-01

    In this study, molecularly imprinting technology and stir bar absorption technology were combined to develop a microextraction approach based on a molecularly imprinted polymeric stir bar. The molecularly imprinted polymer stir bar has a high performance, is specific, economical, and simple to prepare. The obtained naftopidil-imprinted polymer-coated bars could simultaneously agitate and adsorb naftopidil in the sample solution. The ratio of template/monomer/cross-linker and conditions of template removal were optimized to prepare a stir bar with highly efficient adsorption. Fourier transform infrared spectroscopy, scanning electron microscopy, selectivity, and extraction capacity experiments showed that the molecularly imprinted polymer stir bar was prepared successfully. To utilize the molecularly imprinted polymer stir bar for the determination of naftopidil in complex body fluid matrices, the extraction time, stirring speed, eluent, and elution time were optimized. The limits of detection of naftopidil in plasma and urine sample were 7.5 and 4.0 ng/mL, respectively, and the recoveries were in the range of 90-112%. The within-run precision and between-run precision were acceptable (relative standard deviation bar based microextraction with high-performance liquid chromatography was a convenient, rapid, efficient, and specific method for the precise determination of trace naftopidil in clinical analysis. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. The use of laser-induced fluorescence or ultraviolet detectors for sensitive and selective analysis of tobramycin or erythropoietin in complex samples

    Science.gov (United States)

    Ahmed, Hytham M.; Ebeid, Wael B.

    2015-05-01

    Complex samples analysis is a challenge in pharmaceutical and biopharmaceutical analysis. In this work, tobramycin (TOB) analysis in human urine samples and recombinant human erythropoietin (rhEPO) analysis in the presence of similar protein were selected as representative examples of such samples analysis. Assays of TOB in urine samples are difficult because of poor detectability. Therefore laser induced fluorescence detector (LIF) was combined with a separation technique, micellar electrokinetic chromatography (MEKC), to determine TOB through derivatization with fluorescein isothiocyanate (FITC). Borate was used as background electrolyte (BGE) with negative-charged mixed micelles as additive. The method was successively applied to urine samples. The LOD and LOQ for Tobramycin in urine were 90 and 200 ng/ml respectively and recovery was >98% (n = 5). All urine samples were analyzed by direct injection without sample pre-treatment. Another use of hyphenated analytical technique, capillary zone electrophoresis (CZE) connected to ultraviolet (UV) detector was also used for sensitive analysis of rhEPO at low levels (2000 IU) in the presence of large amount of human serum albumin (HSA). Analysis of rhEPO was achieved by the use of the electrokinetic injection (EI) with discontinuous buffers. Phosphate buffer was used as BGE with metal ions as additive. The proposed method can be used for the estimation of large number of quality control rhEPO samples in a short period.

  20. Optimizing Urine Processing Protocols for Protein and Metabolite Detection.

    Science.gov (United States)

    Siddiqui, Nazema Y; DuBois, Laura G; St John-Williams, Lisa; Will, Thompson J; Grenier, Carole; Burke, Emily; Fraser, Matthew O; Amundsen, Cindy L; Murphy, Susan K

    In urine, factors such as timing of voids, and duration at room temperature (RT) may affect the quality of recovered protein and metabolite data. Additives may aid with detection, but can add more complexity in sample collection or analysis. We aimed to identify the optimal urine processing protocol for clinically-obtained urine samples that allows for the highest protein and metabolite yields with minimal degradation. Healthy women provided multiple urine samples during the same day. Women collected their first morning (1 st AM) void and another "random void". Random voids were aliquotted with: 1) no additive; 2) boric acid (BA); 3) protease inhibitor (PI); or 4) both BA + PI. Of these aliquots, some were immediately stored at 4°C, and some were left at RT for 4 hours. Proteins and individual metabolites were quantified, normalized to creatinine concentrations, and compared across processing conditions. Sample pools corresponding to each processing condition were analyzed using mass spectrometry to assess protein degradation. Ten Caucasian women between 35-65 years of age provided paired 1 st morning and random voided urine samples. Normalized protein concentrations were slightly higher in 1 st AM compared to random "spot" voids. The addition of BA did not significantly change proteins, while PI significantly improved normalized protein concentrations, regardless of whether samples were immediately cooled or left at RT for 4 hours. In pooled samples, there were minimal differences in protein degradation under the various conditions we tested. In metabolite analyses, there were significant differences in individual amino acids based on the timing of the void. For comparative translational research using urine, information about void timing should be collected and standardized. For urine samples processed in the same day, BA does not appear to be necessary while the addition of PI enhances protein yields, regardless of 4°C or RT storage temperature.

  1. Silver nanoparticles plasmon resonance-based method for the determination of uric acid in human plasma and urine samples

    International Nuclear Information System (INIS)

    Amjadi, M.; Rahimpour, E.

    2012-01-01

    We have developed a simple and sensitive colorimetric procedure for the quantification of trace amounts of uric acid. It is based on the finding that uric acid in a medium containing ammonia and sodium hydroxide at 65 0 C can reduce silver ions to form yellow silver nanoparticles (Ag NPs). These are stabilized in solution by using poly(vinyl alcohol) as a capping agent. The yellow color of the solution that results from the localized surface plasmon resonance of Ag NPs can be observed by the bare eye. The absorbance at 415 nm is proportional to the concentration of uric acid which therefore can be determined quantitatively. The calibration curve is linear in the concentration range from 10 to 200 nM, with a limit of detection of 3.3 nM. The method was successfully applied to the determination of uric acid in human plasma and urine samples. (author)

  2. Chemical Method of Urine Volume Measurement

    Science.gov (United States)

    Petrack, P.

    1967-01-01

    A system has been developed and qualified as flight hardware for the measurement of micturition volumes voided by crewmen during Gemini missions. This Chemical Urine Volume Measurement System (CUVMS) is used for obtaining samples of each micturition for post-flight volume determination and laboratory analysis for chemical constituents of physiological interest. The system is versatile with respect to volumes measured, with a capacity beyond the largest micturition expected to be encountered, and with respect to mission duration of inherently indefinite length. The urine sample is used for the measurement of total micturition volume by a tracer dilution technique, in which a fixed, predetermined amount of tritiated water is introduced and mixed into the voided urine, and the resulting concentration of the tracer in the sample is determined with a liquid scintillation spectrometer. The tracer employed does not interfere with the analysis for the chemical constituents of the urine. The CUVMS hardware consists of a four-way selector valve in which an automatically operated tracer metering pump is incorporated, a collection/mixing bag, and tracer storage accumulators. The assembled system interfaces with a urine receiver at the selector valve inlet, sample bags which connect to the side of the selector valve, and a flexible hose which carries the excess urine to the overboard drain connection. Results of testing have demonstrated system volume measurement accuracy within the specification limits of +/-5%, and operating reliability suitable for system use aboard the GT-7 mission, in which it was first used.

  3. Oral Fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure.

    Science.gov (United States)

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2017-01-01

    Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multipliedimmunoassay- technique and in oral fluid by liquid chromatography tandem mass spectrometry (LCMSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  4. Determination of human albumin in serum and urine samples by constant-energy synchronous fluorescence method.

    Science.gov (United States)

    Madrakian, Tayyebeh; Bagheri, Habibollah; Afkhami, Abbas

    2015-08-01

    A sensitive spectrofluorimetric method using constant-energy synchronous fluorescence technique is proposed for the determination of human albumin without separation. In this method, no reagent was used for enhancement of the fluorescence signal of albumin in the solution. Effects of some parameters, such as energy difference between excitation and emission monochromators (ΔE), emission and excitation slit widths and scan rate of wavelength were studied and the optimum conditions were established. For this purpose factorial design and response surface method were employed for optimization of the effective parameters on the fluorescence signal. The results showed that the scan rate of the wavelength has no significant effect on the analytical signal. The calibration curve was linear in the range 0.1-220.0 µg mL(-1) of albumin with a detection limit of 7.0 × 10(-3)  µg mL(-1). The relative standard deviations (RSD) for six replicate measurements of albumin were calculated as 2.2%, 1.7% and 1.3% for 0.5, 10.0 and 100.0 µg mL(-1) albumin, respectively. Furthermore the proposed method has been employed for the determination of albumin in human serum and urine samples. Copyright © 2014 John Wiley & Sons, Ltd.

  5. Stability studies of amphetamine and ephedrine derivatives in urine.

    Science.gov (United States)

    Jiménez, C; de la Torre, R; Ventura, M; Segura, J; Ventura, R

    2006-10-20

    Knowledge of the stability of drugs in biological specimens is a critical consideration for the interpretation of analytical results. Identification of proper storage conditions has been a matter of concern for most toxicology laboratories (both clinical and forensic), and the stability of drugs of abuse has been extensively studied. This concern should be extended to other areas of analytical chemistry like antidoping control. In this work, the stability of ephedrine derivatives (ephedrine, norephedrine, methylephedrine, pseudoephedrine, and norpseudoephedrine), and amphetamine derivatives (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), and 3,4-methylenedioxymethamphetamine (MDMA)) in urine has been studied. Spiked urine samples were prepared for stability testing. Urine samples were quantified by GC/NPD or GC/MS. The homogeneity of each batch of sample was verified before starting the stability study. The stability of analytes was evaluated in sterilized and non-sterilized urine samples at different storage conditions. For long-term stability testing, analyte concentration in urine stored at 4 degrees C and -20 degrees C was determined at different time intervals for 24 months for sterile urine samples, and for 6 months for non-sterile samples. For short-term stability testing, analyte concentration was evaluated in liquid urine stored at 37 degrees C for 7 days. The effect of repeated freezing (at -20 degrees C) and thawing (at room temperature) was also studied in sterile urine for up to three cycles. No significant loss of the analytes under study was observed at any of the investigated conditions. These results show the feasibility of preparing reference materials containing ephedrine and amphetamine derivatives to be used for quality control purposes.

  6. The Urine Marker Test: An Alternative Approach to Supervised Urine Collection for Doping Control.

    Science.gov (United States)

    Elbe, Anne-Marie; Jensen, Stine Nylansted; Elsborg, Peter; Wetzke, Monika; Woldemariam, Getachew A; Huppertz, Bernd; Keller, Ruprecht; Butch, Anthony W

    2016-01-01

    Urine sample collection for doping control tests is a key component of the World Anti-Doping Agency's fight against doping in sport. However, a substantial number of athletes experience difficulty when having to urinate under supervision. Furthermore, it cannot always be ensured that athletes are actually delivering their own urine. A method that can be used to alleviate the negative impact of a supervised urination procedure and which can also identify urine as coming from a specific athlete is the urine marker test. Monodisperse low molecular weight polyethylene glycols (PEGs) are given orally prior to urination. Urine samples can be traced to the donor by analysis of the PEGs previously given. The objective of this study was to investigate the use of the urine marker during urine doping control testing. Two studies investigated athletes' acceptance of this new method via two questionnaires (n = 253). Furthermore, a third study (n = 91) investigated whether ingestion of the marker can identify the urine as coming from a specific person and whether the marker interferes with the detection of prohibited substances. The results indicate that this new method finds wide acceptance both from athletes who have only heard about the procedure and those who have actually tested the new method. Furthermore, the marker, which can identify urine as coming from a specific person, does not interfere with the detection of prohibited substances.

  7. Systematic Evaluation of Non-Uniform Sampling Parameters in the Targeted Analysis of Urine Metabolites by 1H,1H 2D NMR Spectroscopy.

    Science.gov (United States)

    Schlippenbach, Trixi von; Oefner, Peter J; Gronwald, Wolfram

    2018-03-09

    Non-uniform sampling (NUS) allows the accelerated acquisition of multidimensional NMR spectra. The aim of this contribution was the systematic evaluation of the impact of various quantitative NUS parameters on the accuracy and precision of 2D NMR measurements of urinary metabolites. Urine aliquots spiked with varying concentrations (15.6-500.0 µM) of tryptophan, tyrosine, glutamine, glutamic acid, lactic acid, and threonine, which can only be resolved fully by 2D NMR, were used to assess the influence of the sampling scheme, reconstruction algorithm, amount of omitted data points, and seed value on the quantitative performance of NUS in 1 H, 1 H-TOCSY and 1 H, 1 H-COSY45 NMR spectroscopy. Sinusoidal Poisson-gap sampling and a compressed sensing approach employing the iterative re-weighted least squares method for spectral reconstruction allowed a 50% reduction in measurement time while maintaining sufficient quantitative accuracy and precision for both types of homonuclear 2D NMR spectroscopy. Together with other advances in instrument design, such as state-of-the-art cryogenic probes, use of 2D NMR spectroscopy in large biomedical cohort studies seems feasible.

  8. Development and validation of an UHPLC-MS/MS method for β2-agonists quantification in human urine and application to clinical samples.

    Science.gov (United States)

    Bozzolino, Cristina; Leporati, Marta; Gani, Federica; Ferrero, Cinzia; Vincenti, Marco

    2018-02-20

    A fast analytical method for the simultaneous detection of 24 β 2 -agonists in human urine was developed and validated. The method covers the therapeutic drugs most commonly administered, but also potentially abused β 2 -agonists. The procedure is based on enzymatic deconjugation with β-glucuronidase followed by SPE clean up using mixed-phase cartridges with both ion-exchange and lipophilic properties. Instrumental analysis conducted by UHPLC-MS/MS allowed high peak resolution and rapid chromatographic separation, with reduced time and costs. The method was fully validated according ISO 17025:2005 principles. The following parameters were determined for each analyte: specificity, selectivity, linearity, limit of detection, limit of quantification, precision, accuracy, matrix effect, recovery and carry-over. The method was tested on real samples obtained from patients subjected to clinical treatment under chronic or acute therapy with either formoterol, indacaterol, salbutamol, or salmeterol. The drugs were administered using pressurized metered dose inhalers. All β 2 -agonists administered to the patients were detected in the real samples. The method proved adequate to accurately measure the concentration of these analytes in the real samples. The observed analytical data are discussed with reference to the administered dose and the duration of the therapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Monitoring and comparison of tritium content in urine

    International Nuclear Information System (INIS)

    Su Feng; Hua Wei; Zheng Chuancheng; Wang Xu; Wen Wanxin

    2009-01-01

    Objective: To ensure the health of staff engaged in tritium, the purpose of experiment is to find out a fast, convenient and reliable sample preparation and measurement methods for such routine monitoring. Methods: We use the conventional distillation decolorization and non-decoloration quenching correction methods dealing with urine sample, and then carried out the urine sample liquid scintillation measurements, statistical analysis between the two measurements. Results: By using above two different methods of sample pretreatment, the results that we measure tritium in urine sample are not obviously different in comparison. Conclusion: The above two different methods can be used for nuclear facilities staff and staff related to conventional tritium detection. However, non-decoloration quenching correction method is simpler and less in time and manpower than the conventional distillation method in operation. It is suitable for a large number of samples prepared, measured, and analyzed in a short period of time. (authors)

  10. The migration of drugs-of-abuse from Europe to Denmark – Analysis of pooled anonymous urine from urinals at Roskilde Festival 2016

    DEFF Research Database (Denmark)

    Hoegberg, Lotte Christine Groth; Christiansen, Cecilie; Soe, Jesper

    or through police seizures [2]. We carried out a cross-sectional study of collected pooled anonymous urine, sampled from urinals at the biggest music festival during the year, Roskilde Festival, with the aim to detect classic recreational drugs and NPS. The aim of this study was to identify recreational...... drugs currently used and predict the emergence of NPS by comparing study data with seizure data from the previous year published by EMCDDA [1]. Methods: In total 44 urine samples were collected from three urinals at Roskilde Festival 2016. Two urinals were placed at music stages with late-night concerts...... drugs were identified in pooled urine samples. While the widespread use of these drugs at the festival was confirmed, the prevalence of NPS was not as comprehensive as expected based on the EMCDDA report [1] and the Danish report on illegal drugs [2]. The limited use of NPS and the substantial dilution...

  11. Urine phenobarbital drug screening: potential use for compliance assessment in neonates.

    Science.gov (United States)

    Guillet, Ronnie; Kwon, Jennifer M; Chen, Sixaio; McDermott, Michael P

    2012-02-01

    This study was done to determine if urine phenobarbital measurements provide a reliable indicator of presence of the drug in neonates. Urine was collected from neonates treated with phenobarbital for clinical indications within 4 to 6 hours of clinically indicated collection of serum phenobarbital levels. Urine samples were also collected from control neonates not treated with phenobarbital. One aliquot was assayed fresh, another frozen at -30°C and assayed 1 to 3 months later. Phenobarbital was assayed using the ONLINE TDM Roche/Hitachi automated clinical chemistry analyzer. Serum and urine concentrations were compared as were fresh and frozen urine measurements. Serum phenobarbital ranged from 5.6 to 52.7 μg/mL. Matched urine samples were 56.6 ± 12.5% of the serum level. Frozen samples were 98.3 ± 8.0% of the fresh samples. Urine phenobarbital concentrations, either fresh or frozen, can be used in neonates as a noninvasive estimate of drug levels.

  12. Estimation of trace levels of plutonium in urine samples by fission track technique

    International Nuclear Information System (INIS)

    Sawant, P.D.; Prabhu, S.; Pendharkar, K.A.; Kalsi, P.C.

    2009-01-01

    Individual monitoring of radiation workers handling Pu in various nuclear installations requires the detection of trace levels of plutonium in bioassay samples. It is necessary to develop methods that can detect urinary excretion of Pu in fraction of mBq range. Therefore, a sensitive method such as fission track analysis has been developed for the measurement of trace levels of Pu in bioassay samples. In this technique, chemically separated plutonium from the sample and a Pu standard were electrodeposited on planchettes and covered with Lexan solid state nuclear track detector (SSNTD) and irradiated with thermal neutrons in APSARA reactor of Bhabha Atomic Research Centre, India. The fission track densities in the Lexan films of the sample and the standard were used to calculate the amount of Pu in the sample. The minimum amount of Pu that can be analyzed by this method using doubly distilled electronic grade (E. G.) reagents is about 12 μBq/L. (author)

  13. Mutagens in urine of carbon electrode workers

    Energy Technology Data Exchange (ETDEWEB)

    Pasquini, R; Monarca, S; Sforzolini, G S; Conti, R; Fagioli, F

    1982-01-01

    Following previous work carried out in an Italian factory producing carbon electrodes and evaluating the occupational mutagenic-carcinogenic hazards, the authors studied the presence of mutagen metabolites in the urine of workers in the same factory who were exposed to petroleum coke and pitch and in the urine of a control group of unexposed workers. The urine samples were concentrated by absorption on XAD-2 columns and were tested using the Salmonella/microsome assay (strain TA98, TA100, TA1535, TA1538) with and without the addition of beta-glucuronidase and metabolizing system. The collection of urine samples was carried out twice, with an interval of 2 months; 'before working time', 'after working time', and also during Sunday. The results showed that urine samples collected 'before' occupational exposure (upon waking) or on Sunday revealed no mutagenic activity in either worker groups and that the urine samples collected after or during occupational exposure revealed high mutagenic activity in the exposed workers, with a statistically significant difference between the mean of the revertants/plate values for exposed and unexposed workers. On the basis of the previous and the present research, the authors suggest that application of the Salmonella/microsome test to work environments could offer useful and suitable tool for evaluating the health hazards due to mutagenic/carcinogenic substances from occupational exposure.

  14. Optimization of HPV DNA detection in urine by improving collection, storage, and extraction.

    Science.gov (United States)

    Vorsters, A; Van den Bergh, J; Micalessi, I; Biesmans, S; Bogers, J; Hens, A; De Coster, I; Ieven, M; Van Damme, P

    2014-11-01

    The benefits of using urine for the detection of human papillomavirus (HPV) DNA have been evaluated in disease surveillance, epidemiological studies, and screening for cervical cancers in specific subgroups. HPV DNA testing in urine is being considered for important purposes, notably the monitoring of HPV vaccination in adolescent girls and young women who do not wish to have a vaginal examination. The need to optimize and standardize sampling, storage, and processing has been reported.In this paper, we examined the impact of a DNA-conservation buffer, the extraction method, and urine sampling on the detection of HPV DNA and human DNA in urine provided by 44 women with a cytologically normal but HPV DNA-positive cervical sample. Ten women provided first-void and midstream urine samples. DNA analysis was performed using real-time PCR to allow quantification of HPV and human DNA.The results showed that an optimized method for HPV DNA detection in urine should (a) prevent DNA degradation during extraction and storage, (b) recover cell-free HPV DNA in addition to cell-associated DNA, (c) process a sufficient volume of urine, and (d) use a first-void sample.In addition, we found that detectable human DNA in urine may not be a good internal control for sample validity. HPV prevalence data that are based on urine samples collected, stored, and/or processed under suboptimal conditions may underestimate infection rates.

  15. Comparison between the urine dipstick and the pH-meter to assess urine pH in sheep and dogs.

    Science.gov (United States)

    Athanasiou, Labrini V; Katsoulos, Panagiotis D; Katsogiannou, Eleni G; Polizopoulou, Zoe S; Diamantaki, Myrto; Kamatsos, Constantinos; Christodoulopoulos, Georgios

    2018-02-06

    Urine pH is an integral part of a complete urinalysis, and is commonly measured in veterinary practice using semiquantitative reagent strips. The aim of this study was to compare the urine pH of dogs and sheep, using visual interpretation of dipstick reactions, and using a pH-meter as the reference method. Agreement between the 2 methods was also assessed. An additional objective was to compare the urine pH before and after centrifugation. A total of 50 voided urine samples from sheep and 52 from dogs were collected into sterile containers. For pH measurements, 2 methods were used, a pH-meter and urine dipstick reagent pads. Measurements were performed using urine samples before (whole urine) and after centrifugation (urine supernatant). For comparison of the 2 methods, Passing and Bablok regression analysis and Bland-Altman plots were used. The equation created to assess agreement between the 2 methods in dogs showed a constant bias at -0.14 and a positive proportional bias at 0.98. From a clinical standpoint, total bias was below and above the maximum acceptable bias in sheep and dogs, respectively. Clinically acceptable bias was also found using centrifuged urine samples in sheep, but the urine pH values before and after centrifugation were nearly identical in dogs. Urine dipstick reagent pads and pH-meters can be used interchangeably to determine urine pH in sheep without needing centrifugation. In contrast, pH-meters provide more accurate pH measurements than urine dipstick pads in canine urine, which is not improved by centrifugation. © 2018 American Society for Veterinary Clinical Pathology.

  16. Water-compatible graphene oxide/molecularly imprinted polymer coated stir bar sorptive extraction of propranolol from urine samples followed by high performance liquid chromatography-ultraviolet detection.

    Science.gov (United States)

    Fan, Wenying; He, Man; You, Linna; Zhu, Xuewei; Chen, Beibei; Hu, Bin

    2016-04-22

    Due to the high selectivity and stability, molecularly imprinted polymers (MIPs) have been successfully applied in stir bar sorptive extraction (SBSE) as a special coating to improve the selective extraction capability for target analytes. However, traditional MIPs usually suffer from incompatibility in aqueous media and low adsorption capacity, which limit the application of MIP coated stir bar in aqueous samples. To solve these problems, a water-compatible graphene oxides (GO)/MIP composite coated stir bar was prepared in this work by in situ polymerization. The prepared water-compatible GO/MIP coated stir bar presented good mechanical strength and chemical stability, and its recognition ability in aqueous samples was improved due to the polymerization of MIP in water environment, the adsorption capacity for target analytes was also increased by the addition of GO in MIP pre-polymer solution. Based on it, a method of water-compatible GO/MIP coated stir bar sorptive extraction combined with high performance liquid chromatography-ultraviolet detector (HPLV-UV) was proposed for the analysis of propranolol (PRO) in aqueous solution. The influencing factors of SBSE, such as sample pH, salt effect, stirring rate, extraction time, desorption solvent and desorption time, were optimized, and the analytical performance of the developed SBSE-HPLC-UV method was evaluated under the optimized conditions. The limit of detection (LOD) of the proposed method for PRO was about 0.37 μg L(-1), and the enrichment factor (EF) was 59.7-fold (theoretical EF was 100-fold). The reproducibility was also investigated at concentrations of 5 μg L(-1) and the relative standard deviation (RSD) was found to be 7.3% (n=7). The proposed method of GO/MIP coating-SBSE-HPLC-UV was successfully applied for the assay of the interested PRO drug in urine samples, and further extended to the investigation of the excretion of the drugs by monitoring the variation of the concentration of PRO in urine

  17. Screening and confirmation of steroids and nitroimidazoles in urine, blood, and food matrices: Sample preparation methods and liquid chromatography tandem mass spectrometric separations.

    Science.gov (United States)

    Tölgyesi, Ádám; Barta, Enikő; Simon, Andrea; McDonald, Thomas J; Sharma, Virender K

    2017-10-25

    Veterinary drugs containing synthetic anabolic steroid and nitroimidazole active agents are not allowed for their applications in livestock of the European Union (EU). This paper presents analyses of twelve selected steroids and six nitroimidazole antibiotics at low levels (1.56μg/L-4.95μg/L and 0.17μg/kg-2.14μg/kg, respectively) in body fluids and egg incurred samples. Analyses involved clean-up procedures, high performance liquid chromatography (HPLC) separation, and tandem mass spectrometric screening and confirmatory methods. Target steroids and nitroimidazoles in samples were cleaned by two independent supported liquid extraction and solid phase extraction procedures. Separation of the selected compounds was conducted on Kinetex XB C-18 HPLC column using gradient elution. The screening methods utilised supported liquid extraction that enabled fast and cost effective clean-up. The confirmatory methods were improved by extending the number of matrices and compounds, and by introducing an isotope dilution mass spectrometry for nitroimidazoles. The new methods were validated according to the recommendation of the European Union Reference Laboratories and the performance characteristics evaluated met fully the criteria. The methods were applied to incurred samples in the proficiency tests. The obtained results of Z-scores demonstrated the applicability of developed protocols of the methods to real samples. The confirmatory methods were applied to the national monitoring program and natural contamination of prednisolone could be detected in urine at low concentration in few samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Neutron activation analysis for bulk and trace elements in urine

    International Nuclear Information System (INIS)

    Cornelis, R.; Speecke, A.; Hoste, J.

    1975-01-01

    Problems in sampling urine for trace element analysis by neutron activation are systematically examined. Collection, storage, sample preparation and contamination hazards during irradiation are studied in detail. Three different sizes of urine samples are prepared for analysis, depending on the concentration and nuclear properties of the elements, and suitable multielement doped urine standards are used. As, Br, Ca, Cl, Co, Cr, Cs, Cu, Hg, I, K, Mg, Mn, Na, Rb, Se and Zn are determined. The extreme care given to sample collection, use of ''ultra-clean'' vials, and work in a dust-free room allows consistent values to be obtained over long periods of time. A literature review of the amounts of forty elements present in urine per day is also given

  19. Spectrophotometric determination of dopamine hydrochloride in pharmaceutical, banana, urine and serum samples by potassium ferricyanide-Fe(III).

    Science.gov (United States)

    Guo, Li; Zhang, Yan; Li, Quanmin

    2009-12-01

    In the present work, we developed a simple, sensitive and inexpensive method to determine dopamine hydrochloride using potassium ferricyanide-Fe(III) by spectrophotometry. The results show that Fe(III) is deoxidized to Fe(II) by dopamine hydrochloride at pH 4.0, and then Fe(II) reacts with potassium ferricyanide to form a soluble prussian blue (KFe(III)[Fe(II)(CN)6]). The absorbance of this product was monitored over time using a spectrophotometer at an absorption maximum of 735 nm, and the amount of dopamine hydrochloride could be calculated based on the absorbance. A good linear relationship of the concentration of dopamine hydrochloride versus absorbance was observed, and a linear regression equation of A = 0.022 + 0.16921C (microg mL(-1)) was obtained. Moreover, the apparent molar absorption coefficient for the indirect determination of dopamine hydrochloride was 3.2 x 10(4) L mol(-1) cm(-1). This described method has been used to determine dopamine hydrochloride in pharmaceutical, banana, urine and serum samples with satisfactory results.

  20. Application of cloud point preconcentration and flame atomic absorption spectrometry for the determination of cadmium and zinc ions in urine, blood serum and water samples

    Directory of Open Access Journals (Sweden)

    Ardeshir Shokrollahi

    2013-01-01

    Full Text Available A simple, sensitive and selective cloud point extraction procedure is described for the preconcentration and atomic absorption spectrometric determination of Zn2+ and Cd2+ ions in water and biological samples, after complexation with 3,3',3",3'"-tetraindolyl (terephthaloyl dimethane (TTDM in basic medium, using Triton X-114 as nonionic surfactant. Detection limits of 3.0 and 2.0 µg L-1 and quantification limits 10.0 and 7.0 µg L-1were obtained for Zn2+ and Cd2+ ions, respectively. Relative standard deviation was 2.9 and 3.3, and enrichment factors 23.9 and 25.6, for Zn2+ and Cd2+ ions, respectively. The method enabled determination of low levels of Zn2+ and Cd2+ ions in urine, blood serum and water samples.

  1. Sample size estimation and sampling techniques for selecting a representative sample

    Directory of Open Access Journals (Sweden)

    Aamir Omair

    2014-01-01

    Full Text Available Introduction: The purpose of this article is to provide a general understanding of the concepts of sampling as applied to health-related research. Sample Size Estimation: It is important to select a representative sample in quantitative research in order to be able to generalize the results to the target population. The sample should be of the required sample size and must be selected using an appropriate probability sampling technique. There are many hidden biases which can adversely affect the outcome of the study. Important factors to consider for estimating the sample size include the size of the study population, confidence level, expected proportion of the outcome variable (for categorical variables/standard deviation of the outcome variable (for numerical variables, and the required precision (margin of accuracy from the study. The more the precision required, the greater is the required sample size. Sampling Techniques: The probability sampling techniques applied for health related research include simple random sampling, systematic random sampling, stratified random sampling, cluster sampling, and multistage sampling. These are more recommended than the nonprobability sampling techniques, because the results of the study can be generalized to the target population.

  2. Accelerator mass spectrometry analysis of "1"4C-oxaliplatin concentrations in biological samples and "1"4C contents in biological samples and antineoplastic agents

    International Nuclear Information System (INIS)

    Toyoguchi, Teiko; Kobayashi, Takeshi; Konno, Noboru; Shiraishi, Tadashi; Kato, Kazuhiro; Tokanai, Fuyuki

    2015-01-01

    Accelerator mass spectrometry (AMS) is expected to play an important role in microdose trials. In this study, we measured the "1"4C concentration in "1"4C-oxaliplatin-spiked serum, urine and supernatant of fecal homogenate samples in our Yamagata University (YU) – AMS system. The calibration curves of "1"4C concentration in serum, urine and supernatant of fecal homogenate were linear (the correlation coefficients were ⩾0.9893), and the precision and accuracy was within the acceptance criteria. To examine a "1"4C content of water in three vacuum blood collection tubes and a syringe were measured. "1"4C was not detected from water in these devices. The mean "1"4C content in urine samples of 6 healthy Japanese volunteers was 0.144 dpm/mL, and the intra-day fluctuation of "1"4C content in urine from a volunteer was little. The antineoplastic agents are administered to the patients in combination. Then, "1"4C contents of the antineoplastic agents were quantitated. "1"4C contents were different among 10 antineoplastic agents; "1"4C contents of paclitaxel injection and docetaxel hydrate injection were higher than those of the other injections. These results indicate that our quantitation method using YU-AMS system is suited for microdosing studies and that measurement of baseline and co-administered drugs might be necessary for the studies in low concentrations.

  3. Accelerator mass spectrometry analysis of {sup 14}C-oxaliplatin concentrations in biological samples and {sup 14}C contents in biological samples and antineoplastic agents

    Energy Technology Data Exchange (ETDEWEB)

    Toyoguchi, Teiko, E-mail: tteiko@med.id.yamagata-u.ac.jp [Department of Pharmacy, Yamagata University Hospital, 2-2-2 Iida-Nishi, Yamagata-shi, Yamagata 990-9585 (Japan); Kobayashi, Takeshi; Konno, Noboru; Shiraishi, Tadashi [Department of Pharmacy, Yamagata University Hospital, 2-2-2 Iida-Nishi, Yamagata-shi, Yamagata 990-9585 (Japan); Kato, Kazuhiro; Tokanai, Fuyuki [Department of Physics, Faculty of Science, Yamagata University, 1-4-12 Kojirakawa-machi, Yamagata-shi, Yamagata 990-8560 (Japan)

    2015-10-15

    Accelerator mass spectrometry (AMS) is expected to play an important role in microdose trials. In this study, we measured the {sup 14}C concentration in {sup 14}C-oxaliplatin-spiked serum, urine and supernatant of fecal homogenate samples in our Yamagata University (YU) – AMS system. The calibration curves of {sup 14}C concentration in serum, urine and supernatant of fecal homogenate were linear (the correlation coefficients were ⩾0.9893), and the precision and accuracy was within the acceptance criteria. To examine a {sup 14}C content of water in three vacuum blood collection tubes and a syringe were measured. {sup 14}C was not detected from water in these devices. The mean {sup 14}C content in urine samples of 6 healthy Japanese volunteers was 0.144 dpm/mL, and the intra-day fluctuation of {sup 14}C content in urine from a volunteer was little. The antineoplastic agents are administered to the patients in combination. Then, {sup 14}C contents of the antineoplastic agents were quantitated. {sup 14}C contents were different among 10 antineoplastic agents; {sup 14}C contents of paclitaxel injection and docetaxel hydrate injection were higher than those of the other injections. These results indicate that our quantitation method using YU-AMS system is suited for microdosing studies and that measurement of baseline and co-administered drugs might be necessary for the studies in low concentrations.

  4. New Functionalized Sol-Gel Hybrid Sorbent Coating for Stir Bar Sorptive Extraction of Selected Non-Steroidal Anti Inflammatory Drugs in Human Urine Samples

    International Nuclear Information System (INIS)

    Mashkurah Abd Rahim; Wan Aini Wan Ibrahim; Zainab Ramli; Mohd Marsin Sanagi

    2015-01-01

    A new sol-gel hybrid material, methyltrimethoxysilane-cyanopropyltriethoxysilane (MTMOS-CNPrTEOS) was successfully synthesized and used as a coating material in stir bar sorptive extraction (SBSE) of selected non-steroidal anti-inflammatory drugs (NSAIDs) in urine samples. The MTMOS-CNPrTEOS hybrid was synthesized by hydrolysis and condensation of MTMOS and CNPrTEOS in the presence of trifluoroacetic acid as catalyst via sol-gel method. Several factors influencing the synthesized sol-gel hybrid MTMOS-CNPrTEOS process such as mole ratio of MTMOS-CNPrTEOS, NaOH concentrations as etching solution, etching time, coating time and water content were investigated and optimized in this study. The optimum synthesis conditions obtained were 1:1 mol ratio of MTMOS-CNPrTEOS, 1 M NaOH as etching solution, 60 min etching time, 2 h coating time and 6 mmol water. The sol-gel hybrid MTMOS-CNPrTEOS synthesized under the optimum conditions was used to determine selected NSAIDs in human urine samples using normal stacking mode capillary electrophoresis with ultraviolet detection. MTMOS-CNPrTEOS SBSE method demonstrated good linearity (60 to 20,000 μg L -1 ) with excellent coefficient of determination (r 2 > 0.9990). The sol-gel hybrid MTMOS-CNPrTEOS SBSE method showed low limit of detection (35 - 41 μg L -1 ) with good precision (RSD < 6 %, n = 3) and excellent extraction recoveries (83.5 - 98.9 %) for the selected NSAIDs. The sol-gel hybrid MTMOS-CNPrTEOS SBSE method demonstrated good potential as an alternative sorbent in SBSE method for NSAIDs. (author)

  5. Collection and storage of urine specimens for measurement of urolithiasis risk factors.

    Science.gov (United States)

    Wu, Wenqi; Yang, Dong; Tiselius, Hans-Goran; Ou, Lili; Mai, Zanlin; Chen, Kang; Zhu, Hanliang; Xu, Shaohong; Zhao, Zhijian; Zeng, Guohua

    2015-02-01

    To evaluate how different methods for storage and preservation of urine samples affected the outcome of analysis of risk factors for stone formation. Spot urine samples were collected from 21 healthy volunteers. Each fresh urine sample was divided into ten 10-mL aliquots: 2 without preservative, 2 with thymol, 2 with toluene, 2 with hydrochloric acid (HCl), and 2 with sodium azide. One sample of each pair was stored at 4 °C and the other at room temperature. The concentrations of calcium, magnesium, sodium, phosphate, urate, oxalate, citrate, and pH in each urine sample were analyzed immediately after collection (0 hour) and after 24 and 48 hours. There were no significant differences in calcium, oxalate, magnesium, phosphate, sodium, urate or pH (without acidification) between samples with different preservation methods (P >.05). Urinary citrate, however, was significantly lower in the urine collected with HCl than when other preservatives were used, both at room temperature and at 4 °C. Urine pH was significantly higher after 48 hours than after 24 hours, whether the samples were stored at room temperature or at 4 °C. Antibacterial preservatives (eg, thymol or toluene) can be recommended as preservatives for 24-hour urine collections. Ideally, the samples should be stored at 4 °C. When HCl is used as a preservative, it seems essential to neutralize the samples before analysis. This is particularly obvious with the chromatographic method used for analysis of citrate that was used in this study. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Development and validation of a sensitive liquid chromatographic-tandem mass spectrometric method for the simultaneous analysis of granisetron and 7-hydroxy granisetron in human plasma and urine samples: application in a clinical pharmacokinetic study in pregnant subject.

    Science.gov (United States)

    Zhao, Yang; Chen, Hui-Jun; Caritis, Steve; Venkataramanan, Raman

    2016-02-01

    A liquid chromatography-tandem mass spectrometric method for the quantification of granisetron and its major metabolite, 7-hydroxy granisetron in human plasma and urine samples was developed and validated. Respective stable isotopically labeled granisetron and 7-hydroxy granisetron were used as internal standards (IS). Chromatography was performed using an Xselect HSS T3 analytical column with a mobile phase of 20% acetonitrile in water (containing 0.2 mM ammonium formate and 0.14% formic acid, pH 4) delivered in an isocratic mode. Tandem mass spectrometry operating in positive electrospray ionization mode with multiple reaction monitoring was used for quantification. The standard curves were linear in the concentration ranges of 0.5-100 ng/mL for granisetron and 0.1-100 ng/mL for 7-hydroxy granisetron in human plasma samples, and 2-2000 ng/mL for granisetron and 2-1000 ng/mL for 7-hydroxy granisetron in human urine samples, respectively. The accuracies were >85% and the precision as determined by the coefficient of variations was granisetron or 7-hydroxy granisetron in either plasma or urine samples. Granisetron was stable under various storage and experimental conditions. This validated method was successfully applied to a pharmacokinetic study after intravenous administration of 1 mg granisetron to a pregnant subject. Copyright © 2015 John Wiley & Sons, Ltd.

  7. A Schistosoma haematobium-specific real-time PCR for diagnosis of urogenital schistosomiasis in serum samples of international travelers and migrants.

    Science.gov (United States)

    Cnops, Lieselotte; Soentjens, Patrick; Clerinx, Jan; Van Esbroeck, Marjan

    2013-01-01

    Diagnosis of urogenital schistosomiasis by microscopy and serological tests may be elusive in travelers due to low egg load and the absence of seroconversion upon arrival. There is need for a more sensitive diagnostic test. Therefore, we developed a real-time PCR targeting the Schistosoma haematobium-specific Dra1 sequence. The PCR was evaluated on urine (n = 111), stool (n = 84) and serum samples (n = 135), and one biopsy from travelers and migrants with confirmed or suspected schistosomiasis. PCR revealed a positive result in 7/7 urine samples, 11/11 stool samples and 1/1 biopsy containing S. haematobium eggs as demonstrated by microscopy and in 22/23 serum samples from patients with a parasitological confirmed S. haematobium infection. S. haematobium DNA was additionally detected by PCR in 7 urine, 3 stool and 5 serum samples of patients suspected of having schistosomiasis without egg excretion in urine and feces. None of these suspected patients demonstrated other parasitic infections except one with Blastocystis hominis and Entamoeba cyst in a fecal sample. The PCR was negative in all stool samples containing S. mansoni eggs (n = 21) and in all serum samples of patients with a microscopically confirmed S. mansoni (n = 22), Ascaris lumbricoides (n = 1), Ancylostomidae (n = 1), Strongyloides stercoralis (n = 1) or Trichuris trichuria infection (n = 1). The PCR demonstrated a high specificity, reproducibility and analytical sensitivity (0.5 eggs per gram of feces). The real-time PCR targeting the Dra1 sequence for S. haematobium-specific detection in urine, feces, and particularly serum, is a promising tool to confirm the diagnosis, also during the acute phase of urogenital schistosomiasis.

  8. Pathogens and pharmaceuticals in source-separated urine in eThekwini, South Africa.

    Science.gov (United States)

    Bischel, Heather N; Özel Duygan, Birge D; Strande, Linda; McArdell, Christa S; Udert, Kai M; Kohn, Tamar

    2015-11-15

    In eThekwini, South Africa, the production of agricultural fertilizers from human urine collected from urine-diverting dry toilets is being evaluated at a municipality scale as a way to help finance a decentralized, dry sanitation system. The present study aimed to assess a range of human and environmental health hazards in source-separated urine, which was presumed to be contaminated with feces, by evaluating the presence of human pathogens, pharmaceuticals, and an antibiotic resistance gene. Composite urine samples from households enrolled in a urine collection trial were obtained from urine storage tanks installed in three regions of eThekwini. Polymerase chain reaction (PCR) assays targeted 9 viral and 10 bacterial human pathogens transmitted by the fecal-oral route. The most frequently detected viral pathogens were JC polyomavirus, rotavirus, and human adenovirus in 100%, 34% and 31% of samples, respectively. Aeromonas spp. and Shigella spp. were frequently detected gram negative bacteria, in 94% and 61% of samples, respectively. The gram positive bacterium, Clostridium perfringens, which is known to survive for extended times in urine, was found in 72% of samples. A screening of 41 trace organic compounds in the urine facilitated selection of 12 priority pharmaceuticals for further evaluation. The antibiotics sulfamethoxazole and trimethoprim, which are frequently prescribed as prophylaxis for HIV-positive patients, were detected in 95% and 85% of samples, reaching maximum concentrations of 6800 μg/L and 1280 μg/L, respectively. The antiretroviral drug emtricitabine was also detected in 40% of urine samples. A sulfonamide antibiotic resistance gene (sul1) was detected in 100% of urine samples. By coupling analysis of pathogens and pharmaceuticals in geographically dispersed samples in eThekwini, this study reveals a range of human and environmental health hazards in urine intended for fertilizer production. Collection of urine offers the benefit of

  9. Effect of Processing Delay and Storage Conditions on Urine Albumin-to-Creatinine Ratio.

    Science.gov (United States)

    Herrington, William; Illingworth, Nicola; Staplin, Natalie; Kumar, Aishwarya; Storey, Ben; Hrusecka, Renata; Judge, Parminder; Mahmood, Maria; Parish, Sarah; Landray, Martin; Haynes, Richard; Baigent, Colin; Hill, Michael; Clark, Sarah

    2016-10-07

    Because there is substantial biologic intraindividual variation in albumin excretion, randomized trials of albuminuria-reducing therapies may need multiple urine samples to estimate daily urinary albumin excretion. Mailing spot urine samples could offer a convenient and cost-effective method to collect multiple samples, but urine albumin-to-creatinine ratio stability in samples stored at ambient temperatures for several days is unknown. Patients with kidney disease provided fresh urine samples in two tubes (with and without boric acid preservative). Reference aliquots from each participant were analyzed immediately, whereas remaining aliquots were subject to different handling/storage conditions before analysis, including delayed processing for up to 7 days at three different storage temperatures (4°C, 18°C, and 30°C), multiple freeze-thaw cycles, and long-term frozen storage at -80°C, -40°C, and -20°C. We calculated the mean percentage change in urine albumin-to-creatinine ratio for each condition, and we considered samples stable if the 95% confidence interval was within a ±5% threshold. Ninety-three patients provided samples with detectable albuminuria in the reference aliquot. Median (interquartile range) urine albumin-to-creatinine ratio was 87 (20-499) mg/g. The inclusion of preservative had minimal effect on fresh urine albumin-to-creatinine ratio measurements but reduced the changes in albumin and creatinine in samples subject to processing delay and storage conditions. The urine albumin-to-creatinine ratio was stable for 7 days in samples containing preservative at 4°C and 18°C and 2 days when stored at 30°C. It was also stable in samples with preservative after three freeze-thaw cycles and in frozen storage for 6 months at -80°C or -40°C but not at -20°C. Mailed urine samples collected with preservative and received within 7 days if ambient temperature is ≤18°C, or within 2 days if the temperature is higher but does not exceed 30°C, are

  10. Effect Of Instructions About The Method Of Urine Collection And ...

    African Journals Online (AJOL)

    Despite the explanation, 15(23.1%) of the patients collected the urine samples wrongly and 44(67.7%) stored the samples for longer than one hour. Significant bacteriuria was more prevalent in 74.2% of patients who submitted their urine samples more than one hour after collection. Communication skill is important and ...

  11. Solid-phase microextraction for gas chromatographic/mass spectrometric analysis of dimethoate in human biological samples.

    Science.gov (United States)

    Gallardo, E; Barroso, M; Margalho, C; Cruz, A; Vieira, D N; López-Rivadulla, M

    2006-01-01

    A new, simple and rapid procedure for the determination of dimethoate in urine and blood samples was developed using direct immersion solid-phase microextraction and gas chromatography/mass spectrometry. This technique required only 0.1 mL of sample, and ethion was used as internal standard. Two types of coated fibre were compared (100 microm polydimethylsiloxane, and 65 microm Carbowax/divinylbenzene). Other parameters, such as extraction temperature, adsorption and desorption time, salt addition, agitation and pH, were optimized to enhance the sensitivity of the method. Limits of detection (LODs) and quantitation (LOQs) were 50 and 100 ng/mL for urine and 200 and 500 ng/mL for blood, respectively. The method was found to be linear between the LOQ and 40 microg/mL for urine, and between the LOQ and 50 microg/mL for blood, with correlation coefficients ranging from 0.9923-0.9996. Precision (intra- and interday) and accuracy were in conformity with the criteria normally accepted in bioanalytical method validation. The mean absolute recoveries of dimethoate were 1.24 and 0.50% for urine and blood, respectively. Because of its simplicity and the fact that small volumes of sample are used, the described method can be successfully used in the diagnosis of poisoning by this pesticide, namely in those situations where the sample volume is limited, as frequently occurs in forensic toxicology. Copyright 2006 John Wiley & Sons, Ltd.

  12. The preservation of urine samples for determination of renal stone risk factors

    Science.gov (United States)

    Nicar, M. J.; Hsu, M. C.; Johnson, T.; Pak, C. Y.

    1987-01-01

    A preservation technique for urine specimens before determination of stone risk factors was evaluated. The purpose of these experiments was to prove the effectiveness of the preservatives used to prevent changes in the concentrations of those constituents measured. Measured concentrations in fresh specimens were compared with those in the same specimens after storage with the preservatives. Refrigeration at 4 degrees C up to five days was appropriate in a laboratory setting, as no significant changes in urinary concentrations occurred. Refrigeration, however, did not offer a convenient method for shipping. Chemical preservation was found to be an effective alternative to refrigeration. Thymol prevented changes in concentration of pH, citrate, uric acid, sulfate, sodium, potassium, and cyclic AMP, while a mixture of hydrochloric (HCl) acid and boric acid prevented changes in calcium, magnesium, phosphorus, oxalate, ammonium, and creatinine. Thus, the addition of thymol or HCl/boric acid to urine specimens will prevent significant changes in the concentrations of stone risk factors.

  13. Comprehensive Molecular Characterization of Escherichia coli Isolates from Urine Samples of Hospitalized Patients in Rio de Janeiro, Brazil

    Directory of Open Access Journals (Sweden)

    Ana Carolina C. Campos

    2018-02-01

    Full Text Available Urinary tract infections (UTIs are often caused by Escherichia coli. Their increasing resistance to broad-spectrum antibiotics challenges the treatment of UTIs. Whereas, E. coli ST131 is often multidrug resistant (MDR, ST69 remains susceptible to antibiotics such as cephalosporins. Both STs are commonly linked to community and nosocomial infections. E. coli phylogenetic groups B2 and D are associated with virulence and resistance profiles making them more pathogenic. Little is known about the population structure of E. coli isolates obtained from urine samples of hospitalized patients in Brazil. Therefore, we characterized E. coli isolated from urine samples of patients hospitalized at the university and three private hospitals in Rio de Janeiro, using whole genome sequencing. A high prevalence of E. coli ST131 and ST69 was found, but other lineages, namely ST73, ST648, ST405, and ST10 were also detected. Interestingly, isolates could be divided into two groups based on their antibiotic susceptibility. Isolates belonging to ST131, ST648, and ST405 showed a high resistance rate to all antibiotic classes tested, whereas isolates belonging to ST10, ST73, ST69 were in general susceptible to the antibiotics tested. Additionally, most ST69 isolates, normally resistant to aminoglycosides, were susceptible to this antibiotic in our population. The majority of ST131 isolates were ESBL-producing and belonged to serotype O25:H4 and the H30-R subclone. Previous studies showed that this subclone is often associated with more complicated UTIs, most likely due to their high resistance rate to different antibiotic classes. Sequenced isolates could be classified into five phylogenetic groups of which B2, D, and F showed higher resistance rates than groups A and B1. No significant difference for the predicted virulence genes scores was found for isolates belonging to ST131, ST648, ST405, and ST69. In contrast, the phylogenetic groups B2, D and F showed a higher

  14. Albumin adsorption onto surfaces of urine collection and analysis containers.

    Science.gov (United States)

    Robinson, Mary K; Caudill, Samuel P; Koch, David D; Ritchie, James; Hortin, Glen; Eckfeldt, John H; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W Greg

    2014-04-20

    Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. We added (125)I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Adsorption of urine albumin (UA) at 5-6 mg/l was containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2-28%) was larger than that from urine. Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Develpoment of a procedure for the determination of chromium in samples of urine and serum by neutron activation analysis

    International Nuclear Information System (INIS)

    Buettner, I.; Hamm, V.; Knoechel, A.; Sen Gupta, R.

    1993-01-01

    Since the mid-fifties the possibility of a causal relationship between deficient chromium and insulin metabolism and the manifestation of certain varieties of diabetes mellitus has been presumed. The determination of the chromium status under pathophysiological conditions may be helpful for the study of this problem. For these purposes an analytical procedure as reference system was developed which allows the determination of chromium in biological matrices down to the concentration of 0.33 ng/ml. It is based on NAA and is used in the framework of a commonly used procedure based on GF-AAS. For its application blood and urine samples are freeze-dried and irradiated. After wet digestion with HNO 3 in a microwave combustion system chromium is separated for measurement from the matrix nuclides with the help of the ion-exchanger Cellex-P. THe individual steps of the procedure were evaluated by means of tracer experiments. (orig.)

  16. Develpoment of a procedure for the determination of chromium in samples of urine and serum by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Buettner, I [Hamburg Univ. (Germany). Inst. for Inorganic and Applied Chemistry; Hamm, V [Hamburg Univ. (Germany). Inst. for Inorganic and Applied Chemistry; Knoechel, A [Hamburg Univ. (Germany). Inst. for Inorganic and Applied Chemistry; Sen Gupta, R [Hamburg Univ. (Germany). Inst. for Inorganic and Applied Chemistry

    1993-06-01

    Since the mid-fifties the possibility of a causal relationship between deficient chromium and insulin metabolism and the manifestation of certain varieties of diabetes mellitus has been presumed. The determination of the chromium status under pathophysiological conditions may be helpful for the study of this problem. For these purposes an analytical procedure as reference system was developed which allows the determination of chromium in biological matrices down to the concentration of 0.33 ng/ml. It is based on NAA and is used in the framework of a commonly used procedure based on GF-AAS. For its application blood and urine samples are freeze-dried and irradiated. After wet digestion with HNO[sub 3] in a microwave combustion system chromium is separated for measurement from the matrix nuclides with the help of the ion-exchanger Cellex-P. THe individual steps of the procedure were evaluated by means of tracer experiments. (orig.)

  17. Proton NMR-based metabolite analyses of archived serial paired serum and urine samples from myeloma patients at different stages of disease activity identifies acetylcarnitine as a novel marker of active disease.

    Directory of Open Access Journals (Sweden)

    Alessia Lodi

    Full Text Available BACKGROUND: Biomarker identification is becoming increasingly important for the development of personalized or stratified therapies. Metabolomics yields biomarkers indicative of phenotype that can be used to characterize transitions between health and disease, disease progression and therapeutic responses. The desire to reproducibly detect ever greater numbers of metabolites at ever diminishing levels has naturally nurtured advances in best practice for sample procurement, storage and analysis. Reciprocally, since many of the available extensive clinical archives were established prior to the metabolomics era and were not processed in such an 'ideal' fashion, considerable scepticism has arisen as to their value for metabolomic analysis. Here we have challenged that paradigm. METHODS: We performed proton nuclear magnetic resonance spectroscopy-based metabolomics on blood serum and urine samples from 32 patients representative of a total cohort of 1970 multiple myeloma patients entered into the United Kingdom Medical Research Council Myeloma IX trial. FINDINGS: Using serial paired blood and urine samples we detected metabolite profiles that associated with diagnosis, post-treatment remission and disease progression. These studies identified carnitine and acetylcarnitine as novel potential biomarkers of active disease both at diagnosis and relapse and as a mediator of disease associated pathologies. CONCLUSIONS: These findings show that samples conventionally processed and archived can provide useful metabolomic information that has important implications for understanding the biology of myeloma, discovering new therapies and identifying biomarkers potentially useful in deciding the choice and application of therapy.

  18. Antibiotic Screening of Urine Culture for Internal Quality Audit at Amrita Hospital, Kochi.

    Science.gov (United States)

    Suresh, Aswathy; Gopinathan, Anusha; Dinesh, Kavitha R; Kumar, Anil

    2017-07-01

    Urine antimicrobial activity is a seldom analysed laboratory test which greatly impacts the quantification of urine specimens. Presence of antimicrobial activity in the urine reduces the bacterial load in these specimens. Hence, the chances of erroneously reporting insignificant bacteriuria can be reduced on analysis of the antimicrobial activity in urine. The aim of the study was to measure the antimicrobial activity of urine samples obtained from patients in a tertiary care hospital. A total of 100 urine specimens were collected from the study group. Tests like wet mount, Gram staining and culture were performed. Antimicrobial susceptibility testing was done on the bacteria isolated from each specimen. The urine specimens were reported as significant bacteriuria (>105 Colony Forming Unit (CFU)/ml) and insignificant bacteriuria (<105 CFU/ml - clean catch midstream urine; <102 CFU/ml - catheterized urine sample) according to the CFU/ml. Staphylococcus aureus ATCC ® 25923 ™ and Escherichia coli ATCC ® 25922 ™ were used to identify the presence of antimicrobial activity in the urine sample by Urine Anti-Bacterial substance Assay (UABA). McNemar test was used for statistical analysis using Statistical Package for the Social Sciences (SPSS) version 21.0. On analysis of the antimicrobial activity of urine sample with the prior antibiotic history of the patients, 17 were true positives and 43 were true negatives. Twenty six of samples with UABA positivity were culture negative and 28 samples with UABA positivity were culture positive. Sensitivity and specificity of the test was 85% and 53.8% respectively. Accuracy of the test was 60%. The p-value of UABA was <0.001. Enterobacteriaceae was the most common bacterial family isolated from the urine specimens. A total of 85% patients responded to treatment. Presence of antimicrobial activity in urine has a great impact on the interpretation of urine culture reports. Identification of urine antimicrobial activity helps

  19. Asymptomatic bacteriuria screened by catheterized samples at pregnancy term in women undergoing cesarean delivery.

    Science.gov (United States)

    Atacag, T; Yayci, E; Guler, T; Suer, K; Yayci, F; Deren, S; Cetin, A

    2015-01-01

    The objective of this study was to assess the frequency of urinary tract infection (UTI) with urine samples obtained via catheterization among women undergoing cesarean delivery at term pregnancy. A cross-sectional study involving 159 women in whom cesarean delivery was conducted at term pregnancy after a regular follow-up from first to third trimester. For screening and diagnosis of UTI during antenatal period, the authors used dipstick test and microscopic urinalysis, and urine culture was used in the presence of symptomatic UTI unresponsive to initial antibiotic therapy. A urine sample was obtained immediately after insertion of Foley catheter for urine dipstick test, microscopic urinalysis, and culture during cesarean delivery. Obstetric and UTI data were recorded. Of 159 pregnant women, 95 (59.8%) did not develop UTI during antenatal care. There was no patient with symptomatic UTI at the admission for cesarean delivery. The authors found UTI with urine dipstick and microscopic urinalysis in 12 patients and of them, four patients had no history of UTI, and all the remaining eight patients had asymptomatic UTI during antenatal follow-up. UTI according to urine culture was encountered in three patients, two of them had one episode of UTI, and one had two episodes of UTI during antenatal follow-up. After regular antenatal follow-up screening with urine dipstick, microscopic urinalysis, and counseling of pregnant women regarding UTIs, the frequency of bacteriuria decreases considerably during cesarean delivery.

  20. Effect of Processing Delay and Storage Conditions on Urine Albumin-to-Creatinine Ratio

    Science.gov (United States)

    Illingworth, Nicola; Staplin, Natalie; Kumar, Aishwarya; Storey, Ben; Hrusecka, Renata; Judge, Parminder; Mahmood, Maria; Parish, Sarah; Landray, Martin; Haynes, Richard; Baigent, Colin; Hill, Michael; Clark, Sarah

    2016-01-01

    Background and objectives Because there is substantial biologic intraindividual variation in albumin excretion, randomized trials of albuminuria-reducing therapies may need multiple urine samples to estimate daily urinary albumin excretion. Mailing spot urine samples could offer a convenient and cost-effective method to collect multiple samples, but urine albumin-to-creatinine ratio stability in samples stored at ambient temperatures for several days is unknown. Design, setting, participants, & measurements Patients with kidney disease provided fresh urine samples in two tubes (with and without boric acid preservative). Reference aliquots from each participant were analyzed immediately, whereas remaining aliquots were subject to different handling/storage conditions before analysis, including delayed processing for up to 7 days at three different storage temperatures (4°C, 18°C, and 30°C), multiple freeze-thaw cycles, and long–term frozen storage at −80°C, −40°C, and −20°C. We calculated the mean percentage change in urine albumin-to-creatinine ratio for each condition, and we considered samples stable if the 95% confidence interval was within a ±5% threshold. Results Ninety-three patients provided samples with detectable albuminuria in the reference aliquot. Median (interquartile range) urine albumin-to-creatinine ratio was 87 (20–499) mg/g. The inclusion of preservative had minimal effect on fresh urine albumin-to-creatinine ratio measurements but reduced the changes in albumin and creatinine in samples subject to processing delay and storage conditions. The urine albumin-to-creatinine ratio was stable for 7 days in samples containing preservative at 4°C and 18°C and 2 days when stored at 30°C. It was also stable in samples with preservative after three freeze-thaw cycles and in frozen storage for 6 months at −80°C or −40°C but not at −20°C. Conclusions Mailed urine samples collected with preservative and received within 7 days if

  1. Study of nominal daily output of urine from workers

    International Nuclear Information System (INIS)

    Lima, Marina F.; Carneiro, Janete C.G. Gaburo; Todo, Alberto S.

    2007-01-01

    A retrospective study of the 24-hour urine volumes from workers selected for the internal individual monitoring compares the average volume collected by sample and the average volume per individual with the nominal daily output of urine from 'Reference Man'. This work considers 134 registers of urine samples from 18 male workers, with semester routine sampling, between the years of 2000 and 2005. For this group, the average volume per collection was (971±371)mL and (962±376)mL per individual. In a cohort group of 9 male workers, which supplied at least 10 samples in this period, it was observed that the average volume per collection decreased to (955±308)mL and the average volume per individual increased to (1027±400)mL. For the female group, composed by 11 individuals, the 29 urine samples supplied between 1999 and 2005 were considered. The average volume per sampling and for worker was, respectively, (1122±337)mL and (1105±337)mL. Another cohort group of only 4 female workers with at least one annual collection during five years, of the seven years considered, the values decreased to (1112±336)mL per collection and the average volume per individual was maintained. The major variability of the volume among all the individuals was 927%, and for the same individual was 562%. This difference can be indicative of the individual differences of retention and excretion, alimentary diet interferences and for lack of awareness by the individual to collect urine during a period of 24-hour. The radionuclides clearance does not occur in constant rates and for the purpose of assessing intakes, in our routine analysis, the total volume of urine from worker is corrected for 1,4 L. Based in the results obtained over the years, and to minimize the errors of the nominal daily excretion rate in urine, actions about the aware of the individual in carrying out an accurately sampling and/or the implementation of the measurements of creatinine levels in urine are suggested

  2. Detection of mycobacterium tuberculosis in clinical samples by smear and culture

    International Nuclear Information System (INIS)

    Aftab, R.; Amjad, F.; Khurshid, R.

    2009-01-01

    A retrospective study was carried out in order to compare the smear stained by ZN and Lowenstein-Jensen (U) medium for the detection of Mycobacterium in clinical samples from different categories. Study Design: Laboratory based, Retrospective. Place and Duration: Sir Ganga Ram Hospital Fatima Jinnah Medical College, Lahore over a 5 year period between Jan 2001 and June 2006. Material and Methods: A total of 798 clinical samples were collected from patients of both sexes and all ages with a provisional diagnosis of tuberculosis. A Ziehl-Neelsen stain (ZN) and culture on U medium was performed for the detection of Mycobacterium. The specimen categories were sputum, pus, lymph node aspirate, urine and endometrial curetting. Results: Out of 5 types of 798 specimens received over a period of five years, only 46.3%) (n=369) were respiratory whereas the remaining 53.7% (n=429) were non respiratory tract category samples including sputum, pus, lymph node aspirate, urine and endometrial curetting. All were examined for the presence of acid-fast-bacilli (AFB) in ZN smear. Among these 3.578% gave a positive ZN stain while 11.65% were positive on culture. Out of a total of 369 respiratory tract category samples, 38 (10.3%) sputum samples were positive for AFB on both ZN and culture. Among the non respiratory tract category, 47 (28.2%) pus, 26 (31%) LN aspirate, 5 (15.6%) urine, 5 (3.42%) endometrial curetting were reported positive. Only 15.16% of clinical samples belonging to 5 different categories of specimens received from patients of both sexes with a provisional diagnosis of tuberculosis, tested positive for Mycobacterium by both ZN stain smear and culture on U medium. Among these, 3.57% were positive for AFB on ZN smear and 11.65% were positive on culture on U medium. Conclusion: These conventional techniques have proved to be reliable testing tools for detection of Mycobacterium tuberculosis in our settings but there is an urgent need to promote the use of Biotic and

  3. Are They Bloody Guilty? Blood Doping with Simulated Samples

    Science.gov (United States)

    Stuart, Parker E.; Lees, Kelsey D.; Milanick, Mark A.

    2014-01-01

    In this practice-based lab, students are provided with four Olympic athlete profiles and simulated blood and urine samples to test for illegal substances and blood-doping practices. Throughout the course of the lab, students design and conduct a testing procedure and use their results to determine which athletes won their medals fairly. All of the…

  4. Ex vivo spontaneous generation of 19-norandrostenedione and nandrolone detected in equine plasma and urine.

    Science.gov (United States)

    Guan, Fuyu; Uboh, Cornelius E; Soma, Lawrence R; You, Youwen; Li, Xiaoqing; McDonnell, Sue

    2012-01-01

    19-Norandrostenedione (NAED) and nandrolone are anabolic-androgenic steroids (AASs). Nandrolone was regarded solely as a synthetic AAS until the 1980s when trace concentrations of apparently endogenous nandrolone were detected in urine samples obtained from intact male horses (stallions). Since then, its endogenous origin has been reported in boars and bulls; endogenous NAED and nandrolone have been identified in plasma and urine samples collected from stallions. More recently, however, it was suggested that NAED and nandrolone detected in urine samples from stallions are primarily artifacts due to the analytical procedure. The present study was undertaken to determine whether NAED and nandrolone detected in plasma and urine samples collected from stallions are truly endogenous or artifacts from sample processing. To answer this question, fresh plasma and urine samples from ≥8 stallions were analyzed for the two AASs, soon after collection, by liquid chromatography hyphenated to tandem mass spectrometry (LC-MS/MS). NAED and nandrolone were not detected in fresh plasma samples but detected in the same samples post storage. Concentrations of both AASs increased with storage time, and the increases were greater at a higher storage temperature (37°C versus 4°C, and ambient temperature versus 4°C). Although NAED was detected in some fresh stallion urine samples, its concentration (samples post storage (at ambient temperature for 15 days). Nandrolone was not detected in most of fresh urine samples but detected in the same samples post storage. Based on these results, it is concluded that all NAED and nandrolone detected in stored plasma samples of stallions and most of them in the stored urine samples are not from endogenous origins but spontaneously generated during sample storage, most likely from spontaneous decarboxylation of androstenedione-19-oic acid and testosterone-19-oic acid. To our knowledge, it is the first time that all NAED and nandrolone detected in

  5. Towards a method of rapid extraction of strontium-90 from urine: urine pretreatment and alkali metal removal

    Energy Technology Data Exchange (ETDEWEB)

    Hawkins, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Dietz, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Kaminski, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Mertz, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Shkrob, I. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-03-01

    A technical program to support the Centers of Disease Control and Prevention is being developed to provide an analytical method for rapid extraction of Sr-90 from urine, with the intent of assessing the general population’s exposure during an emergency response to a radiological terrorist event. Results are presented on the progress in urine sample preparation and chemical separation steps that provide an accurate and quantitative detection of Sr-90 based upon an automated column separation sequence and a liquid scintillation assay. Batch extractions were used to evaluate the urine pretreatment and the column separation efficiency and loading capacity based upon commercial, extractant-loaded resins. An efficient pretreatment process for decolorizing and removing organics from urine without measurable loss of radiostrontium from the sample was demonstrated. In addition, the Diphonix® resin shows promise for the removal of high concentrations of common strontium interferents in urine as a first separation step for Sr-90 analysis.

  6. Evaluation of storage conditions for tritiated thymidine as reference organically-bound tritium in urine

    International Nuclear Information System (INIS)

    Duong, T.; Trivedi, A.

    1997-01-01

    Interlaboratory intercomparison exercises have used tritiated thymidine as a reference material for organically-bound tritium (OBT) measurements in urine. We have examined the effects of storage conditions on the degradation behavior of tritium from OBT to tritiated water (HTO) in artificial and natural human urine samples. Tritiated thymidine decomposed less readily in artificial urine than natural urine samples. The degradation rate of tritiated thymidine in artificial urine, at -20 deg C, is about 10% for the first month. The rate of tritium conversion from OBT to HTO is the same at 4 deg C, but this storage temperature is less preferable, because of the danger of microbial contamination in the reference samples. The storage of the reference urine samples beyond three months after the preparation date is not recommended for quality control measurement data. (author)

  7. Study of urinary 6 beta-hydroxycortisol/cortisol ratio in spot urine sample as a biomarker of 3A4 enzyme activity in healthy and epileptic subjects of Egyptian population.

    Science.gov (United States)

    El Desoky, Ehab S; Mohamed, Hanan O; Farghaly, Wafaa M A; Hamed, Sherifa A; Hedaya, Mohsen A; Siest, Jean-Pascal

    2005-06-01

    The ratio of urinary 6 beta-hydroxycortisol/cortisol (6 beta-OHC/FC) in morning spot urine samples collected from 8:00 a.m. to 12:00 p.m. was studied using ELIZA kits (Stabiligen) in a group of healthy adult Egyptians (control group) of both sex (n=65, age range: 16-48 years). The frequency distribution of urinary 6 beta-OHC/FC ratio was widely distributed among subjects with higher values in males in comparison to females. No bimodality in either sex was observed. Another group of adult epileptic patients (n=16) was studied for the influence of chronic carbamazepine antiepileptic drug administration on urinary 6 beta-OHC/FC ratio in spot urine samples. The induction property of carbamazepine on CYP3A4 was observed through significant increase (p=0.01) in 6 beta-OHC/FC ratio among epileptic patients in comparison with control subjects. In conclusion, the frequency distribution of urinary 6 beta-OHC/FC ratio among Egyptians shows sexual dimorphism. Also, measurement of urinary 6 beta-OHC/FC ratio provides a simple non-invasive method to monitor CYP3A4 enzyme induction during administration of carbamazepine antiepileptic drug.

  8. Molecular Diagnosis of Trichomoniasis in Negative Samples Examined by Direct Smear and Culture

    Directory of Open Access Journals (Sweden)

    Z Valadkhani

    2010-12-01

    Full Text Available Background: Trichomoniasis is an extremely common sexually transmitted infection (STI world­wide and is associated with important public health problems, including amplification of HIV transmission. This disease is in forms of symptomatic and asymptomatic in women and may de­pend on host as well as parasite variables. Most of the studies reported from females are based on examination of vaginal secretions and urine samples by direct smear and culture in modified Dia­mond's media. The aim of this study was checking the samples, which were negative by direct smear and culture, with PCR technique.Methods: The urine samples and vaginal discharge of patients attending Gynecology Clinics of Ma­zandaran Province, Iran with different symptoms rechecked for Trichomonas vaginalis by PCR technique using primers targeting a conserved region of the beta-tubulin genes of the para­site. Data were analyzed by Epi Info software programResults: Out of 161 negative samples by direct smear and culture, seven samples (4.3% were posi­tive by PCR technique.Conclusion: Diagnosis of trichomoniasis by PCR is a sensitive and specific method that could play important role to help the physicians for properly treatment and control of infection.

  9. 24-hour urine protein

    Science.gov (United States)

    ... your provider may be able to order a test that is done on just one urine sample (protein-to-creatinine ratio). Normal Results The normal ... Some labs use different measurements or test different samples. Talk to your provider about the meaning of your specific test ... Abnormal results may be due to: A group ...

  10. Behavior of Phenols and Phenoxyacids on a Bisphenol-A Imprinted Polymer. Application for Selective Solid-Phase Extraction from Water and Urine Samples

    Directory of Open Access Journals (Sweden)

    Eliseo Herrero-Hernández

    2011-05-01

    Full Text Available A molecularly imprinted polymer (MIP, obtained by precipitation polymerisation with 4-vinylpyridine as the functional monomer, ethylene glycol dimethacrylate as cross-linker, and bisphenol-A (BPA as template, was prepared. The binding site configuration of the BPA-MIP was examined using Scatchard analysis. Moreover, the behaviour of the BPA-MIP for the extraction of several phenolic compounds (bisphenol-A, bisphenol-F, 4-nitrophenol, 3-methyl-4-nitrophenol and phenoxyacid herbicides such as 2,4-D, 2,4,5-T and 2,4,5-TP has been studied in organic and aqueous media in the presence of other pesticides in common use. It was possible to carry out the selective preconcentration of the target analytes from the organic medium with recoveries of higher than 70%. In an aqueous medium, hydrophobic interactions were found to exert a remarkably non-specific contribution to the overall binding process. Several parameters affecting the extraction efficiency of the BPA-MIP were evaluated to achieve the selective preconcentration of phenols and phenoxyacids from aqueous samples. The possibility of using the BPA-MIP as a selective sorbent to preconcentrate these compounds from other samples such as urine and river water was also explored.

  11. Feline urine metabolomic signature: characterization of low-molecular-weight substances in urine from domestic cats.

    Science.gov (United States)

    Rivera-Vélez, Sol-Maiam; Villarino, Nicolas F

    2018-02-01

    Objectives This aim of this study was to characterize the composition and content of the feline urine metabolome. Methods Eight healthy domestic cats were acclimated at least 10 days before starting the study. Urine samples (~2 ml) were collected by ultrasound-guided cystocentesis. Samples were centrifuged at 1000 × g for 8 mins, and the supernatant was analyzed by gas chromatography/time-of-flight mass spectrometery. The urine metabolome was characterized using an untargeted metabolomics approach. Results Three hundred and eighteen metabolites were detected in the urine of the eight cats. These molecules are key components of at least 100 metabolic pathways. Feline urine appears to be dominated by carbohydrates, carbohydrate conjugates, organic acid and derivatives, and amino acids and analogs. The five most abundant molecules were phenaceturic acid, hippuric acid, pseudouridine phosphate and 3-(4-hydroxyphenyl) propionic acid. Conclusions and relevance This study is the first to characterize the feline urine metabolome. The results of this study revealed the presence of multiple low-molecular-weight substances that were not known to be present in feline urine. As expected, the origin of the metabolites detected in urine was diverse, including endogenous compounds and molecules biosynthesized by microbes. Also, the diet seemed to have had a relevant role on the urine metabolome. Further exploration of the urine metabolic phenotype will open a window for discovering unknown, or poorly understood, metabolic pathways. In turn, this will advance our understanding of feline biology and lead to new insights in feline physiology, nutrition and medicine.

  12. A Novel and Sensitive Method for the Determination of Vitamin B2 (Riboflavin in Urine and Pharmaceutical Samples Using an Aqueous Two-Phase Extraction

    Directory of Open Access Journals (Sweden)

    Sabah Shiri

    2013-01-01

    Full Text Available A novel, simple, and more sensitive spectrophotometric procedure has been developed for the determination of vitamin B2 (riboflavin by an aqueous two-phase extraction (ATPE. An ATPE is formed mostly by water and does not require an organic solvent. Other ATPE components used in this study were the polymer, polyethylene glycol (PEG, and some salts such as Na2SO4 and Na2CO3. The method is based on the interaction between vitamin B2 (riboflavin and sodium sulfate (Na2SO4 in an acidic medium (pH 6.4. The influences of effective parameters such as salt (type and concentration, polyethylene glycol (molecular weight and concentration, temperature, centrifuging time, and pH of the sample solution were studied and optimized. The linear range was 1.3–320 ng/mL (R2=0.9991; n=10 with the relative standard deviation (RSD for 60 ng/mL 3.68%. The limit of detection (LOD calculated from three times of standard deviation of blank were 0.2 ng/mL and recoveries from analysis of real samples between 94.82% and 103.98% were obtained for the determination of vitamin B2 (riboflavin in urine and pharmaceutical samples.

  13. Mining the human urine proteome for monitoring renal transplant injury

    Energy Technology Data Exchange (ETDEWEB)

    Sigdel, Tara K.; Gao, Yuqian; He, Jintang; Wang, Anyou; Nicora, Carrie D.; Fillmore, Thomas L.; Shi, Tujin; Webb-Robertson, Bobbie-Jo; Smith, Richard D.; Qian, Wei-Jun; Salvatierra, Oscar; Camp, David G.; Sarwal, Minnie M.

    2016-06-01

    The human urinary proteome reflects systemic and inherent renal injury perturbations and can be analyzed to harness specific biomarkers for different kidney transplant injury states. 396 unique urine samples were collected contemporaneously with an allograft biopsy from 396 unique kidney transplant recipients. Centralized, blinded histology on the graft was used to classify matched urine samples into categories of acute rejection (AR), chronic allograft nephropathy (CAN), BK virus nephritis (BKVN), and stable graft (STA). Liquid chromatography–mass spectrometry (LC-MS) based proteomics using iTRAQ based discovery (n=108) and global label-free LC-MS analyses of individual samples (n=137) for quantitative proteome assessment were used in the discovery step. Selected reaction monitoring (SRM) was applied to identify and validate minimal urine protein/peptide biomarkers to accurately segregate organ injury causation and pathology on unique urine samples (n=151). A total of 958 proteins were initially quantified by iTRAQ, 87% of which were also identified among 1574 urine proteins detected in LC-MS validation. 103 urine proteins were significantly (p<0.05) perturbed in injury and enriched for humoral immunity, complement activation, and lymphocyte trafficking. A set of 131 peptides corresponding to 78 proteins were assessed by SRM for their significance in an independent sample cohort. A minimal set of 35 peptides mapping to 33 proteins, were modeled to segregate different injury groups (AUC =93% for AR, 99% for CAN, 83% for BKVN). Urinary proteome discovery and targeted validation identified urine protein fingerprints for non-invasive differentiation of kidney transplant injuries, thus opening the door for personalized immune risk assessment and therapy.

  14. Detection of human papillomavirus DNA in urine. A review of the literature.

    Science.gov (United States)

    Vorsters, A; Micalessi, I; Bilcke, J; Ieven, M; Bogers, J; Van Damme, P

    2012-05-01

    The detection of human papillomavirus (HPV) DNA in urine, a specimen easily obtained by a non-invasive self-sampling method, has been the subject of a considerable number of studies. This review provides an overview of 41 published studies; assesses how different methods and settings may contribute to the sometimes contradictory outcomes; and discusses the potential relevance of using urine samples in vaccine trials, disease surveillance, epidemiological studies, and specific settings of cervical cancer screening. Urine sampling, storage conditions, sample preparation, DNA extraction, and DNA amplification may all have an important impact on HPV DNA detection and the form of viral DNA that is detected. Possible trends in HPV DNA prevalence in urine could be inferred from the presence of risk factors or the diagnosis of cervical lesions. HPV DNA detection in urine is feasible and may become a useful tool but necessitates further improvement and standardization.

  15. A NEW TECHNIQUE FOR FAST AND SAFE COLLECTION OF URINE IN NEW BORNS

    Directory of Open Access Journals (Sweden)

    Pratap

    2016-01-01

    Full Text Available INTRODUCTION Clean urine samples are necessary to accurately diagnose several diseases in new-borns, especially Urinary Tract Infections (UTIs. A wide range of clinical interventions for urine collection is described in the literature including non-invasive and invasive methods. The most common non-invasive technique is urine collection using sterile bags, which is associated with significant patient discomfort and contamination of samples. Obtaining a clean-catch urine sample is the recommended method for urine collection in children able to co-operate. However, in children lacking sphincter control, urine catch is more difficult and time-consuming and invasive methods (catheterization and needle aspiration of urine from the bladder are sometimes needed. There are some stimulation techniques that facilitate emptying of the bladder in situations of bladder dysfunction. We hypothesized that the use of such methods in new-borns could facilitate the collection of a clean-catch urine sample. The aim of this study was to determine the success rate and safety of a new non-invasive technique to obtain clean-catch urine samples in newborns. AIM To describe and test a new technique to obtain midstream urine samples in newborns. MATERIALS AND METHODS This was a prospective, feasible and safety study conducted in Mahatma Gandhi Memorial Hospital, Warangal, (A secondary centre with a 20-bed neonatal unit, a 130-beded pediatric ward. This study was carried out over 7 months (January-July 2015. Patients consisted of 100 consecutively admitted infants aged less than 30 days who needed a urine analysis according to their attending physician. RESULTS This technique was successful in 72% of newborns. Mean time to sample collection was 56.99 Sec. No complications other than controlled crying were observed. CONCLUSION A new, quick and safe technique with a high success rate is described, whereby the discomfort and waste of time usually associated with bag

  16. Rapid determination of nine parabens and seven other environmental phenols in urine samples of German children and adults.

    Science.gov (United States)

    Moos, Rebecca K; Angerer, Jürgen; Wittsiepe, Jürgen; Wilhelm, Michael; Brüning, Thomas; Koch, Holger M

    2014-11-01

    We developed a fast, selective and sensitive on-line LC/LC-MS/MS method for the simultaneous determination of nine parabens and seven environmental phenols in urine. Parabens are widely used as antimicrobial preservatives. Bisphenol A, triclosan, triclocarban, 2-phenylphenol, and benzophenones are used inter alia in disinfectants, sunscreens and in polymers. Some of these substances are suspected endocrine disruptors. Limits of quantification and analytical quality criteria fully met the needs for determining exposure levels occurring in the general population. We analyzed 157 spot urine samples from the general German population (59 females, 39 males and 59 children). For the parabens, we found methyl, ethyl and n-propyl paraben with high detection rates (77-98%), followed by n-butyl (36%), iso-butyl (17%), iso-propyl (3%) and benzyl paraben (3%). We detected no pentyl and heptyl paraben. Urinary concentrations were highest for methyl paraben (median 24.5 μg/L; 95th percentile 379 μg/L) followed by ethyl (1.4 μg/L; 35.2 μg/L) and n-propyl paraben (1.2 μg/L; 68.1 μg/L). Other environmental phenols with high detection rates were BPA (95%), triclosan (45%) and benzophenone 1 and 3 (26%). For most of the parabens/environmental phenols we found higher urinary levels in females than in males or children, probably due to differences in (personal care) product use. However, high levels (in the mg/L range) were also observed in children. Exposure to the above substances is occurring worldwide. Differences between countries do seem to exist and might be caused by different product compositions or different use habits. Human metabolism data is urgently needed to extrapolate from urinary biomarker levels to doses actually taken up. Copyright © 2014 Elsevier GmbH. All rights reserved.

  17. Metabolomic biomarkers in serum and urine in women with preeclampsia.

    Directory of Open Access Journals (Sweden)

    Marie Austdal

    Full Text Available To explore the potential of magnetic resonance (MR metabolomics for study of preeclampsia, for improved phenotyping and elucidating potential clues to etiology and pathogenesis.Urine and serum samples from pregnant women with preeclampsia (n = 10, normal pregnancies (n = 10 and non-pregnant women (n = 10 matched by age and gestational age were analyzed with MR spectroscopy and subjected to multivariate analysis. Metabolites were then quantified and compared between groups.Urine and serum samples revealed clear differences between women with preeclampsia and both control groups (normal pregnant and non-pregnant women. Nine urine metabolites were significantly different between preeclampsia and the normal pregnant group. Urine samples from women with early onset preeclampsia clustered together in the multivariate analysis. The preeclampsia serum spectra showed higher levels of low and very-low density lipoproteins and lower levels of high-density lipoproteins when compared to both non-pregnant and normal pregnant women.The MR determined metabolic profiles in urine and serum from women with preeclampsia are clearly different from normal pregnant women. The observed differences represent a potential to examine mechanisms underlying different preeclampsia phenotypes in urine and serum samples in larger studies. In addition, similarities between preeclampsia and cardiovascular disease in metabolomics are demonstrated.

  18. The effect of substrate composition and storage time on urine specific gravity in dogs.

    Science.gov (United States)

    Steinberg, E; Drobatz, K; Aronson, L

    2009-10-01

    The purpose of this study is to evaluate the effects of substrate composition and storage time on urine specific gravity in dogs. A descriptive cohort study of 15 dogs. The urine specific gravity of free catch urine samples was analysed during a 5-hour time period using three separate storage methods; a closed syringe, a diaper pad and non-absorbable cat litter. The urine specific gravity increased over time in all three substrates. The syringe sample had the least change from baseline and the diaper sample had the greatest change from baseline. The urine specific gravity for the litter and diaper samples had a statistically significant increase from the 1-hour to the 5-hour time point. The urine specific gravity from canine urine stored either on a diaper or in a non-absorbable litter increased over time. Although the change was found to be statistically significant over the 5-hour study period it is unlikely to be clinically significant.

  19. Development and application of carbon nanotubes assisted electromembrane extraction (CNTs/EME) for the determination of buprenorphine as a model of basic drugs from urine samples.

    Science.gov (United States)

    Hasheminasab, Kobra Sadat; Fakhari, Ali Reza

    2013-03-12

    In this work carbon nanotubes assisted electromembrane extraction (CNTs/EME) coupled with capillary electrophoresis (CE) and ultraviolet (UV) detection was developed for the determination of buprenorphine as a model of basic drugs from urine samples. Carbon nanotubes reinforced hollow fiber was used in this research. Here the CNTs serve as a sorbent and provide an additional pathway for solute transport. The presence of CNTs in the hollow fiber wall increased the effective surface area and the overall partition coefficient on the membrane; and lead to an enhancement in the analyte transport. For investigating the influence of the presence of CNTs in the SLM on the extraction efficiency, a comparative study was carried out between EME and CNTs/EME methods. Optimization of the variables affecting these methods was carried out in order to achieve the best extraction efficiency. Optimal extractions were accomplished with NPOE as the SLM, with 200V as the driving force, and with pH 2.0 in the donor and pH 1.0 in the acceptor solutions with the whole assembly agitated at 750rpm after 25min and 15min for EME and CNTs/EME, respectively. Under the optimized conditions, in comparison with the conventional EME method, CNTs/EME provided higher extraction efficiencies in shorter time. This method provided lower limit of detection (1ngmL(-1)), higher preconcentration factor (185) and higher recovery (92). Finally, the applicability of this method was evaluated by the extraction and determination of buprenorphine in patients' urine samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Development of an analytical method for the direct determination of uranium isotopes in occupationally exposed personnel urine samples using Icp-SFMS; Desarrollo de un metodo analitico para la determinacion directa de isotopos de uranio en muestras de orina de personal ocupacionalmente expuesto (POE) usando ICP-SFMS

    Energy Technology Data Exchange (ETDEWEB)

    Torres C, C. O.; Hernandez M, H.; Romero G, E. T. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Vega C, H. R., E-mail: hector.hernandez@inin.gob.mx [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98060 Zacatecas, Zac. (Mexico)

    2016-09-15

    The development of an analytical method for measuring actinides in radioactive waste, environmental and biological samples has been a major challenge in institutions dedicated to the nuclear sector. Is for this reason that the developed and validated methods to measure isotopes of elements belonging to the actinide family have as main objective the characterization of radioactive wastes, the monitoring of radioactive installations and the dosimetric evaluation of occupationally exposed personnel, this for the purpose to prevent incidents or radiological accidents and to safeguard workers. This research work is focused on determining isotopes of uranium (U) and obtaining isotope ratios in urine samples of occupationally exposed personnel using a Magnetic Sector Mass Spectrometer with Inductively Coupled Plasma Source (Icp-SFMS), which is a versatile and promising technique for a large number of applications. The urine samples are acidified in order to favor the dissolution of the analytes in the samples, minimizing as much as possible their loss by sorption in the walls of the sampling bottle. For the determination of U in urine samples, dilution was performed, taking 2 ml of the urine samples and weighing it to 100 ml with 2% ultra pure HNO{sub 3} and finally performing the measurement by Icp-SFMS. The results obtained in the measurements of U show an order of magnitude in terms of sensitivity offered by Icp-SFMS. The isotopic ratios {sup 234}U/{sup 238}U, {sup 235}U/{sup 238}U are very close to the results reported by the literature and the quantification of the isotopes of said element show be within the concentration range of U, indicating that is exposed to depleted U. Additionally, Limit of Detection and Quantification Limit calculations were performed, which are of the order of pg mL{sup -1}. (Author)

  1. Calibration of a liquid scintillation counter to assess tritium levels in various samples

    CERN Document Server

    Al-Haddad, M N; Abu-Jarad, F A

    1999-01-01

    An LKB-Wallac 1217 Liquid Scintillation Counter (LSC) was calibrated with a newly adopted cocktail. The LSC was then used to measure tritium levels in various samples to assess the compliance of tritium levels with the recommended international levels. The counter was calibrated to measure both biological and operational samples for personnel and for an accelerator facility at KFUPM. The biological samples include the bioassay (urine), saliva, and nasal tests. The operational samples of the light ion linear accelerator include target cooling water, organic oil, fomblin oil, and smear samples. Sets of standards, which simulate various samples, were fabricated using traceable certified tritium standards. The efficiency of the counter was obtained for each sample. The typical range of the efficiencies varied from 33% for smear samples down to 1.5% for organic oil samples. A quenching curve for each sample is presented. The minimum detectable activity for each sample was established. Typical tritium levels in bio...

  2. [Molecular epidemiology and antifungal susceptibility of Candida species isolated from urine samples of patients in intensive care unit].

    Science.gov (United States)

    Yüksekkaya, Serife; Fındık, Duygu; Arslan, Uğur

    2011-01-01

    The aims of this study were to analyse the amphotericin B and fluconazole susceptibility and molecular epidemiology of Candida strains (Candida albicans, Candida tropicalis and Candida glabrata) isolated from the urine samples of patients hospitalized in the intensive care unit. Identification of the isolates was done according to microscopic morphology (chlamydospor, blastospor, pseudohyphae and true hyphae) on cornmeal agar, germ tube formation and carbohydrate assimilation patterns (API ID 32C bioMérieux, France). Antifungal susceptibilities of the isolates were determined by in vitro broth microdilution method recommended by Clinical and Laboratory Standards Institute (CLSI). To investigate the clonal relationship of the isolates, randomly amplified polymorphic DNA (RAPD) analysis was performed by using Cnd3 primer. Of the 56 Candida isolates minimum inhibitory concentration (MIC) ranges, MIC50 and MIC90 values for amphotericin B were 0.125-1 µg/ml, 0.125 and 0.5 µg/ml for C.albicans, 0.125-1 µg/ml, 0.25 and 1 µg/ml for C.tropicalis and 0.125-1 µg/ml, 0.25 and 1 µg/ml for C.glabrata, respectively. Fluconazole MIC ranges, MIC50 and MIC90 values were 0.25-4 µg/ml, 0.25 and 0.5 µg/ml for C.albicans, 0.25-16 µg/ml, 0.5 and 1 µg/ml for C.tropicalis and 0.5-64 µg/ml, 8 and 16 µg/ml for C.glabrata, respectively. For amphotericin B, none of the isolates had high MIC values (MIC > 1 µg/ml). While one of the C.glabrata isolates was resistant to fluconazole (MIC ≥ 64 µg/ml), one C.tropicalis and two C.glabrata isolates were dose-dependent susceptible (MIC: 16-32 µg/ml). The results of RAPD analysis indicated an exogenous spread from two clones for C.albicans, one clone for C.glabrata and one clone for C.tropicalis. This study underlines the importance of molecular epidemiological analysis of clinical samples together with hospital environmental samples in terms of Candida spp. To determine the exogenous origin for the related strains and to prevent

  3. Optimization of analytical and pre-analytical conditions for MALDI-TOF-MS human urine protein profiles.

    Science.gov (United States)

    Calvano, C D; Aresta, A; Iacovone, M; De Benedetto, G E; Zambonin, C G; Battaglia, M; Ditonno, P; Rutigliano, M; Bettocchi, C

    2010-03-11

    Protein analysis in biological fluids, such as urine, by means of mass spectrometry (MS) still suffers for insufficient standardization in protocols for sample collection, storage and preparation. In this work, the influence of these variables on healthy donors human urine protein profiling performed by matrix assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was studied. A screening of various urine sample pre-treatment procedures and different sample deposition approaches on the MALDI target was performed. The influence of urine samples storage time and temperature on spectral profiles was evaluated by means of principal component analysis (PCA). The whole optimized procedure was eventually applied to the MALDI-TOF-MS analysis of human urine samples taken from prostate cancer patients. The best results in terms of detected ions number and abundance in the MS spectra were obtained by using home-made microcolumns packed with hydrophilic-lipophilic balance (HLB) resin as sample pre-treatment method; this procedure was also less expensive and suitable for high throughput analyses. Afterwards, the spin coating approach for sample deposition on the MALDI target plate was optimized, obtaining homogenous and reproducible spots. Then, PCA indicated that low storage temperatures of acidified and centrifuged samples, together with short handling time, allowed to obtain reproducible profiles without artifacts contribution due to experimental conditions. Finally, interesting differences were found by comparing the MALDI-TOF-MS protein profiles of pooled urine samples of healthy donors and prostate cancer patients. The results showed that analytical and pre-analytical variables are crucial for the success of urine analysis, to obtain meaningful and reproducible data, even if the intra-patient variability is very difficult to avoid. It has been proven how pooled urine samples can be an interesting way to make easier the comparison between

  4. Urine nickel concentrations in nickel-exposed workers.

    Science.gov (United States)

    Bernacki, E J; Parsons, G E; Roy, B R; Mikac-Devic, M; Kennedy, C D; Sunderman, F W

    1978-01-01

    Electrothermal atomic absorption spectrometry was employed for analyses of nickel concentrations in urine samples from nickel-exposed workers in 10 occupational groups and from non-exposed workers in two control groups. Mean concentrations of nickel in urine were greatest in workers who were exposed to inhalation of aerosols of soluble nickel salts (e.g., workers in nickel plating operations and in an electrolytic nickel refinery). Less marked increases in urine nickel concentrations were found in groups of metal sprayers, nickel battery workers, bench mechanics and are welders. No significant increases in mean concentrations of nickel were found in urine samples from workers who performed grinding, buffing and polishing of nickel-containing alloys or workers in a coal gasification plant who employed Raney nickel as a hydrogenation catalyst. Measurements of nickel concentrations in urine are more sensitive and practical than measurements of serum nickel concentrations for evaluation of nickel exposures in industrial workers.

  5. Concentrations of Environmental Chemicals in Urine and Blood Samples of Children from San Luis Potosí, Mexico.

    Science.gov (United States)

    Perez-Maldonado, Ivan N; Ochoa-Martinez, Angeles C; Orta-Garcia, Sandra T; Ruiz-Vera, Tania; Varela-Silva, Jose A

    2017-08-01

    Human biomonitoring (HBM) is an appreciated tool used to evaluate human exposure to environmental, occupational or lifestyle chemicals. Therefore, the aim of this study was to evaluate the exposure levels for environmental chemicals in urine and blood samples of children from San Luis Potosí, Mexico (SLP). This study identifies environmental chemicals of concern such as: arsenic (45.0 ± 15.0 µg/g creatinine), lead (5.40 ± 2.80 µg/dL), t,t-muconic acid (266 ± 220 µg/g creatinine), 1-hydroxypyrene (0.25 ± 0.15 µmol/mol creatinine), PBDEs (28.0 ± 15.0 ng/g lipid), and PCBs (33.0 ± 16.0 ng/g lipid). On the other hand, low mercury (1.25 ± 1.00 µg/L), hippuric acid (0.38 ± 0.15 µg/g creatinine) and total DDT (130 ± 35 ng/g lipid) exposure levels were found. This preliminary study showed the tool's utility, as the general findings revealed chemicals of concern. Moreover, this screening exhibited the need for HBM in the general population of SLP.

  6. Amines as extracting agents for the quantitative determinations of actinides in biological samples

    International Nuclear Information System (INIS)

    Singh, N.P.

    1987-01-01

    The use of amines (primary, secondary and tertiary chains and quaternary ammonium salts) as extracting agents for the quantitative determination of actinides in biological samples is reviewed. Among the primary amines, only Primene JM-T is used to determine Pu in urine and bone. No one has investigated the possibility of using secondary amines to quantitatively extract actinides from biological samples. Among the tertiary amines, tri-n-octylamine, tri-iso-octylamine, tyricaprylamine (Alamine) and trilaurylamine (tridodecylamine) are used extensively to extract and separate the actinides from biological samples. Only one quaternary ammonium salt, methyltricapryl ammonium chloride (Aliquat-336), is used to extract Pu from biological samples. (author) 28 refs

  7. Drop-on-demand sample introduction system coupled with the flowing atmospheric-pressure afterglow for direct molecular analysis of complex liquid microvolume samples.

    Science.gov (United States)

    Schaper, J Niklas; Pfeuffer, Kevin P; Shelley, Jacob T; Bings, Nicolas H; Hieftje, Gary M

    2012-11-06

    One of the fastest developing fields in analytical spectrochemistry in recent years is ambient desorption/ionization mass spectrometry (ADI-MS). This burgeoning interest has been due to the demonstrated advantages of the method: simple mass spectra, little or no sample preparation, and applicability to samples in the solid, liquid, or gaseous state. One such ADI-MS source, the flowing atmospheric-pressure afterglow (FAPA), is capable of direct analysis of solids just by aiming the source at the solid surface and sampling the produced ions into a mass spectrometer. However, direct introduction of significant volumes of liquid samples into this source has not been possible, as solvent loads can quench the afterglow and, thus, the formation of reagent ions. As a result, the analysis of liquid samples is preferably carried out by analyzing dried residues or by desorbing small amounts of liquid samples directly from the liquid surface. In the former case, reproducibility of sample introduction is crucial if quantitative results are desired. In the present study, introduction of liquid samples as very small droplets helps overcome the issues of sample positioning and reduced levels of solvent intake. A recently developed "drop-on-demand" (DOD) aerosol generator is capable of reproducibly producing very small volumes of liquid (∼17 pL). In this paper, the coupling of FAPA-MS and DOD is reported and applications are suggested. Analytes representing different classes of substances were tested and limits of detections were determined. Matrix tolerance was investigated for drugs of abuse and their metabolites by analyzing raw urine samples and quantification without the use of internal standards. Limits of detection below 2 μg/mL, without sample pretreatment, were obtained.

  8. Validation of an analytical method for the determination of total mercury in urine samples using cold vapor atomic absorption spectrometry (CV-AAS)

    International Nuclear Information System (INIS)

    Guilhen, Sabine Neusatz

    2009-01-01

    Mercury (Hg) is a toxic metal applied to a variety of products and processes, representing a risk to the health of occupationally or accidentally exposed subjects. Dental amalgam is a restorative material composed of metallic mercury, which use has been widely debated in the last decades. Due to the dubiety of the studies concerning dental amalgam, many efforts concerning this issue have been conducted. The Tropical Medicine Foundation (Tocantins, Brazil) has recently initiated a study to evaluate the environmental and occupational levels of exposure to mercury in dentistry attendants at public consulting rooms in the city of Araguaina (TO). In collaboration with this study, the laboratory of analysis at IPEN's Chemistry and Environment Center is undertaking the analysis of mercury levels in exposed subjects' urine samples using cold vapor atomic absorption spectrometry. This analysis requires the definition of a methodology capable of generating reliable results. Such methodology can only be implemented after a rigorous validation procedure. As part of this work, a series of tests were conducted in order to confirm the suitability of the selected methodology and to assert that the laboratory addresses all requirements needed for a successful implementation of the methodology. The following parameters were considered in order to test the method's performance: detection and quantitation limits, selectivity, sensitivity, linearity, accuracy and precision. The assays were carried out with certified reference material, which assures the traceability of the results. Taking into account the estimated parameters, the method can be considered suitable for the afore mentioned purpose. The mercury concentration found for the reference material was of (95,12 +- 11,70)mug.L -1 with a recovery rate of 97%. The method was also applied to 39 urine samples, six of which (15%) showing urinary mercury levels above the normal limit of 10μg.L -1 . The obtained results fall into a

  9. Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection

    Directory of Open Access Journals (Sweden)

    Ewa Jaszczak

    2017-01-01

    Full Text Available A simple and accurate ion chromatography (IC method with pulsed amperometric detection (PAD was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1–100 μg/L for urine, 5–100 μg/L for saliva, and 3–100 μg/L for sweat samples with determination coefficients (R>0.992. Low detection limits (LODs in the range of 1.8 μg/L, 5.1 μg/L, and 5.8 μg/L for urine, saliva, and sweat samples, respectively, and good repeatability (CV < 3%, n=3 were obtained. The proposed method has been successfully applied to the analysis of human biological samples.

  10. Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection.

    Science.gov (United States)

    Jaszczak, Ewa; Ruman, Marek; Narkowicz, Sylwia; Namieśnik, Jacek; Polkowska, Żaneta

    2017-01-01

    A simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1-100  μ g/L for urine, 5-100  μ g/L for saliva, and 3-100  μ g/L for sweat samples with determination coefficients ( R ) > 0.992. Low detection limits (LODs) in the range of 1.8  μ g/L, 5.1  μ g/L, and 5.8  μ g/L for urine, saliva, and sweat samples, respectively, and good repeatability (CV < 3%, n = 3) were obtained. The proposed method has been successfully applied to the analysis of human biological samples.

  11. A Modified Catheterization Procedure to Reduce Bladder Damage when Collecting Urine Samples from Holstein Cows

    Science.gov (United States)

    TAMURA, Tetsuo; NAKAMURA, Hiroshi; SATO, Say; SEKI, Makoto; NISHIKI, Hideto

    2014-01-01

    ABSTRACT This study proposed a modified procedure, using a small balloon catheter (SB catheter, 45 ml), for reducing bladder damage in cows. Holstein cows and the following catheters were prepared: smaller balloon catheter (XSB catheter; 30 ml), SB catheter and standard balloon catheter (NB catheter; 70 ml, as the commonly used, standard size). In experiment 1, each cow was catheterized. The occurrence of catheter-associated hematuria (greater than 50 RBC/HPF) was lower in the SB catheter group (0.0%, n=7) than in the NB catheter group (71.4%, n=7; P<0.05). In experiment 2, general veterinary parameters, urine pH, body temperature and blood values in cows were not affected before or after insertion of SB catheters (n=6). The incidence of urinary tract infection (UTI) was 3.0% per catheterized day (n=22). In experiment 3, feeding profiles, daily excretion of urinary nitrogen (P<0.05) and rate from nitrogen intake in urine (P<0.01), were higher with use of the SB catheter (n=13) than with the use of the vulva urine cup (n=18), indicating that using the SB catheter can provide accurate nutritional data. From this study, we concluded that when using an SB catheter, the following results occur; reduction in bladder damage without any veterinary risks and accuracy in regard to feeding parameters, suggesting this modified procedure using an SB catheter is a useful means of daily urine collection. PMID:24561376

  12. Urine Galactomannan-to-Creatinine Ratio for Detection of Invasive Aspergillosis in Patients with Hematological Malignancies

    OpenAIRE

    Reischies, Frederike M. J.; Raggam, Reinhard B.; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin

    2016-01-01

    Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with...

  13. A novel coated silver ketamine(I electrode for potentiometric determination of ketamine hydrochloride in ampoules and urine samples

    Directory of Open Access Journals (Sweden)

    Hazem M. Abu Shawish

    2014-11-01

    Full Text Available A new ketamine coated silver electrode (KCSE based on ketamine hydrochloride with sodium tetraphenylborate (KT-TPB as electroactive material has been described. The influence of membrane composition, type of solvent mediators, kind of electroactive materials and interfering ions on the sensor was investigated. The sensor displays Nernstian response of 55.8 ± 0.3 mV/decade over the concentration range of 2.5 × 10−6 to 1.0 × 10−2 M with limit of detection of 8.5 × 10−7 M. The coated wire electrode has short response time ∼8 s and it can be used in pH range of 2.6–6.4. The selective coefficients were determined in relation to several inorganic, organic ions, sugars and some common drug excipients. The KCSE electrode was successfully used for the determination of the ketamine content in ampoule and urine samples with satisfactory results. Statistical student’s t-test and F test showed insignificant systematic error between proposed and official methods.

  14. Sweat: a sample with limited present applications and promising future in metabolomics.

    Science.gov (United States)

    Mena-Bravo, A; Luque de Castro, M D

    2014-03-01

    Sweat is a biofluid with present scant use as clinical sample. This review tries to demonstrate the advantages of sweat over other biofluids such as blood or urine for routine clinical analyses and the potential when related to metabolomics. With this aim, critical discussion of sweat samplers and equipment for analysis of target compounds in this sample is made. Well established routine analyses in sweat as is that to diagnose cystic fibrosis, and the advantages and disadvantages of sweat versus urine or blood for doping control have also been discussed. Methods for analytes such as essential metals and xenometals, ethanol and electrolytes in sweat in fact constitute target metabolomics approaches or belong to any metabolomics subdiscipline such as metallomics, ionomics or xenometabolomics. The higher development of biomarkers based on genomics or proteomics as omics older than metabolomics is discussed and also the potential role of metabolomics in systems biology taking into account its emergent implementation. Normalization of the volume of sampled sweat constitutes a present unsolved shortcoming that deserves investigation. Foreseeable trends in this area are outlined. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Frequency of Haemophilus spp. in urinary and and genital tract samples

    Directory of Open Access Journals (Sweden)

    Tatjana Marijan,

    2010-02-01

    Full Text Available Aim To determine the prevalence and antibiotic susceptibility of Haemophilus influenzae and H. parainfluenzae isolated from the urinary and genital tracts. Methods Identification of strains bacteria Haemophilus spp. was carried out by using API NH identifi-cation system, and antibiotic susceptibility was performed by Kirby-Bauer disk diffusion method. Results A total number of 50 (0,03% H. influenzae and 14 (0,01% H. parainfluenzae (out of 180, 415 samples were isolated from genitourinary tract. From urine samples of the girls under 15 years of age these bacteria were isolated in 13 (0,88% and two (0,13% cases, respectively, and only in one case(0,11% of the UTI in boys (H. influenzae. In persons of fertile age, it was only H. influenzae bacteria that was found in urine samples of the five women (0,04% and in three men (0,22%. As a cause of vulvovaginitis, H. influenzae was isolated in four (5,63%, and H. parainfluenzae in two (2,82% girls. In persons of fertile age, H. influenzae was isolated from 10 (0,49% smears of the cervix, and in nine (1,74% male samples. H. parainfluenzae was isolated from seven (1,36% male samples. (p<0.01. Susceptibility testing of H. influenzae and H. parainfluenzae revealed that both pathogens were signifi- cantly resistant to cotrimoxasol only (26.0% and 42.9%, respectively. Conclusion In the etiology of genitourinary infections of girls during childhood, genital infections of women in fertile age (especially in pregnant women, and men with cases of epididimytis and/or orchitis,it is important to think about this rare and demanding bacteria in terms of cultivation.

  16. A magnetic bead-based method for concentrating DNA from human urine for downstream detection.

    Science.gov (United States)

    Bordelon, Hali; Russ, Patricia K; Wright, David W; Haselton, Frederick R

    2013-01-01

    Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pipette bulb to a small diameter tube, and captured biomarkers were concentrated using magnetic entrainment of beads through pre-arrayed wash solutions separated by small air gaps. Feasibility was tested using synthetic segments of the 140 bp tuberculosis IS6110 DNA sequence spiked into pooled human urine samples. DNA recovery was evaluated by qPCR. Despite the presence of spiked DNA, no DNA was detectable in unextracted urine samples, presumably due to the presence of PCR inhibitors. However, following extraction with the magnetic bead-based method, we found that ∼50% of spiked TB DNA was recovered from human urine containing roughly 5×10(3) to 5×10(8) copies of IS6110 DNA. In addition, the DNA was concentrated approximately ten-fold into water. The final concentration of DNA in the eluate was 5×10(6), 14×10(6), and 8×10(6) copies/µL for 1, 3, and 5 mL urine samples, respectively. Lyophilized and freshly prepared reagents within the transfer pipette produced similar results, suggesting that long-term storage without refrigeration is possible. DNA recovery increased with the length of the spiked DNA segments from 10±0.9% for a 75 bp DNA sequence to 42±4% for a 100 bp segment and 58±9% for a 140 bp segment. The estimated LOD was 77 copies of DNA/µL of urine. The strategy presented here provides a simple means to achieve high nucleic acid recovery from easily obtained urine samples, which does not contain inhibitors of PCR.

  17. Systematic sampling with errors in sample locations

    DEFF Research Database (Denmark)

    Ziegel, Johanna; Baddeley, Adrian; Dorph-Petersen, Karl-Anton

    2010-01-01

    analysis using point process methods. We then analyze three different models for the error process, calculate exact expressions for the variances, and derive asymptotic variances. Errors in the placement of sample points can lead to substantial inflation of the variance, dampening of zitterbewegung......Systematic sampling of points in continuous space is widely used in microscopy and spatial surveys. Classical theory provides asymptotic expressions for the variance of estimators based on systematic sampling as the grid spacing decreases. However, the classical theory assumes that the sample grid...... is exactly periodic; real physical sampling procedures may introduce errors in the placement of the sample points. This paper studies the effect of errors in sample positioning on the variance of estimators in the case of one-dimensional systematic sampling. First we sketch a general approach to variance...

  18. [A comparison of convenience sampling and purposive sampling].

    Science.gov (United States)

    Suen, Lee-Jen Wu; Huang, Hui-Man; Lee, Hao-Hsien

    2014-06-01

    Convenience sampling and purposive sampling are two different sampling methods. This article first explains sampling terms such as target population, accessible population, simple random sampling, intended sample, actual sample, and statistical power analysis. These terms are then used to explain the difference between "convenience sampling" and purposive sampling." Convenience sampling is a non-probabilistic sampling technique applicable to qualitative or quantitative studies, although it is most frequently used in quantitative studies. In convenience samples, subjects more readily accessible to the researcher are more likely to be included. Thus, in quantitative studies, opportunity to participate is not equal for all qualified individuals in the target population and study results are not necessarily generalizable to this population. As in all quantitative studies, increasing the sample size increases the statistical power of the convenience sample. In contrast, purposive sampling is typically used in qualitative studies. Researchers who use this technique carefully select subjects based on study purpose with the expectation that each participant will provide unique and rich information of value to the study. As a result, members of the accessible population are not interchangeable and sample size is determined by data saturation not by statistical power analysis.

  19. Selenium speciation in urine by ion-pairing chromatography with perfluorinated carboxylic acids and ICP-MS detection

    DEFF Research Database (Denmark)

    Gammelgaard, Bente; Bendahl, L.; Sidenius, U.

    2002-01-01

    Five aqueous standards, selenomethionine (SeMet), methylselenomethionine (MeSeMet), methylselenocysteine (MeSeCys), selenogammaaminobutyric acid (SeGaba) and the trimethylselenonium ion (TMSe), were separated in ion-pairing chromatographic systems based on perfluorinated carboxylic acids in metha...... were major compounds in urine samples-even after massive consumption of selenium-containing supplements. The selenium species in the urine samples showed a limited stability, as they changed during storage at +4 degreesC as well as -18 degreesC...... of between 2.3 and 5.1 pg. Urine samples from different individuals before and during supplementation with selenomethionine were analysed. Several species were separated in the different urine samples. A major component eluting at the beginning of the chromatogram was predominant in many samples, especially...... after selenium consumption. This species was not identified and solid phase extraction experiments suggested that it was neutral. When different urine samples were spiked with the available standards, co-elution of species with TMSe, MeSeMet or SeMet was observed in some samples. None of these species...

  20. Albumin to creatinine ratio in a random urine sample: Correlation with severity of preeclampsia

    Directory of Open Access Journals (Sweden)

    Fady S. Moiety

    2014-06-01

    Conclusions: Random urine ACR may be a reliable method for prediction and assessment of severity of preeclampsia. Using the estimated cut-off may add to the predictive value of such a simple quick test.

  1. An evaluation of an organically bound tritium measurement method in artificial and natural urine

    International Nuclear Information System (INIS)

    Trivedi, A.; Duong, T.

    1993-03-01

    The accurate measurement of tritium in urine in the form of tritiated water (HTO) as well as in organic forms (organically bound tritium (OBT)) is an essential step in assessing tritium exposures correctly. Exchange between HTO and OBT, arising intrinsically in the separation of HTO from urine samples, is a source of error in determining the concentration of OBT using the low-temperature distillation (LTD) bioassay method. The accuracy and precision of OBT measurements using the LTD method was investigated using spiked natural and artificial urine samples. The relative bias for most of the measurements was less than 25%. The choice of testing matrix, artificial urine versus human urine, made little difference: the precisions for each urine type were similar. The appropriateness of the use of artificial urine for testing purposes was judged using a ratio of performance indices. Based on this evaluation, the artificial urine is a suitable test matrix for intercomparisons of OBT in urine measurements. It is further concluded that the LTD method is reliable for measuring OBT in urine samples. (author). 7 refs., 6 tabs

  2. An evaluation of an organically bound tritium measurement method in artificial and natural urine

    Energy Technology Data Exchange (ETDEWEB)

    Trivedi, A; Duong, T

    1993-03-01

    The accurate measurement of tritium in urine in the form of tritiated water (HTO) as well as in organic forms (organically bound tritium (OBT)) is an essential step in assessing tritium exposures correctly. Exchange between HTO and OBT, arising intrinsically in the separation of HTO from urine samples, is a source of error in determining the concentration of OBT using the low-temperature distillation (LTD) bioassay method. The accuracy and precision of OBT measurements using the LTD method was investigated using spiked natural and artificial urine samples. The relative bias for most of the measurements was less than 25%. The choice of testing matrix, artificial urine versus human urine, made little difference: the precisions for each urine type were similar. The appropriateness of the use of artificial urine for testing purposes was judged using a ratio of performance indices. Based on this evaluation, the artificial urine is a suitable test matrix for intercomparisons of OBT in urine measurements. It is further concluded that the LTD method is reliable for measuring OBT in urine samples. (author). 7 refs., 6 tabs.

  3. The optimization of the analysis of chlorine-36 in urine

    International Nuclear Information System (INIS)

    Joseph, S.; Kramer, G.H.

    1982-02-01

    A method has been developed and optimized for the analysis of chlorine-36 in urine. Problems such as sample size, photodecomposition of silver chloride and anion interferences have been solved and are discussed in detail. The analysis is performed by first removing interfering phosphates and sulphates from an untreated urine sample and isolating the chlorine-36 as silver chloride. The precipitate is counted in a planchet counter. Recoveries are estimated to be 90 +- 5% with a detection limit of 3 pCi (0.1 Bq) for a routine sample (counting time 10 minutes, counting efficiency 10%, sample size 100 mL)

  4. Electrochemical Analysis of Antichemotherapeutic Drug Zanosar in Pharmaceutical and Biological Samples by Differential Pulse Polarography

    Directory of Open Access Journals (Sweden)

    Chennupalle Nageswara Reddy

    2013-01-01

    Full Text Available The electrochemical reduction of zanosar was investigated systematically by direct current polarography, cyclic voltammetry, and differential pulse polarography (DPP. A simple DPP technique was proposed for the direct quantitative determination of anticancer drug zanosar in pharmaceutical formulation and spiked human urine samples for the first time. The reduction potential was −0.28 V versus Ag/AgCl with a hanging mercury drop electrode in Britton-Robinson buffer as supporting electrolyte. The dependence of the intensities of currents and potentials on pH, concentration, scan rate, deposition time, and nature of the supporting electrolyte was investigated. The calibration curve was found to be linear with the following equation: y=0.4041x+0.012, with a correlation coefficient of 0.992 (R2 over a concentration range from 1.0×10-7 M to 1.0×10-3 M. In the present investigation, the achieved limit of detection (LOD and limit of quantization (LQD were 7.42×10-8 M and 2.47×10-8 M; respectively. Excipients did not interfere with the determination of zanosar in pharmaceutical formulation and spiked urine samples. Precision and accuracy of the developed method were checked by recovery studies in pharmaceutical formulation and spiked human urine samples.

  5. Electrochemical analysis of antichemotherapeutic drug zanosar in pharmaceutical and biological samples by differential pulse polarography.

    Science.gov (United States)

    Reddy, Chennupalle Nageswara; Reddyprasad, Puthalapattu; Sreedhar, Neelamyughandhar

    2013-01-01

    The electrochemical reduction of zanosar was investigated systematically by direct current polarography, cyclic voltammetry, and differential pulse polarography (DPP). A simple DPP technique was proposed for the direct quantitative determination of anticancer drug zanosar in pharmaceutical formulation and spiked human urine samples for the first time. The reduction potential was -0.28 V versus Ag/AgCl with a hanging mercury drop electrode in Britton-Robinson buffer as supporting electrolyte. The dependence of the intensities of currents and potentials on pH, concentration, scan rate, deposition time, and nature of the supporting electrolyte was investigated. The calibration curve was found to be linear with the following equation: y = 0.4041x + 0.012, with a correlation coefficient of 0.992 (R (2)) over a concentration range from 1.0 × 10(-7) M to 1.0 × 10(-3) M. In the present investigation, the achieved limit of detection (LOD) and limit of quantization (LQD) were 7.42 × 10(-8) M and 2.47 × 10(-8) M; respectively. Excipients did not interfere with the determination of zanosar in pharmaceutical formulation and spiked urine samples. Precision and accuracy of the developed method were checked by recovery studies in pharmaceutical formulation and spiked human urine samples.

  6. Detection and quantification of rituximab in the human urine.

    Science.gov (United States)

    Jacobs, Roland; Langer-Jacobus, Thais; Duong, Michelle; Stahl, Klaus; Haller, Hermann; Schmidt, Reinhold E; Schiffer, Mario

    2017-12-01

    B cell depletion by rituximab treatment might be inefficient in patients suffering from nephrotic syndrome. Due to the impaired glomerular filtration barrier a significant portion of the therapeutic antibody might be lost into the urinary space. In order to determine the amount of rituximab in the urine of such patients, CD20+ Daudi cells were stained with the patients' urine followed by a fluorochrome-labeled secondary antibody. Mean fluorescence intensity of that way labeled Daudi cells was determined by flow cytometry. Control samples with defined rituximab concentrations were used to create standard curves. The analyses revealed that all nephelometric IgG+ urine samples tested also manifested rituximab at concentrations between 100 and 46,707μg/L. The flow cytometry-based approach is an easy and reliable method to assess rituximab in patients' urine samples for monitoring individual rituximab treatment courses in all patients co-presenting impaired renal filtration. Presence of such antibodies in the urine could be considered as criteria to modify the formulation or modality of rituximab delivery in order to prevent the loss of the therapeutic antibodies and thereby ensuring efficacy of the therapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. A simple method for estimation of phosphorous in urine

    International Nuclear Information System (INIS)

    Chaudhary, Seema; Gondane, Sonali; Sawant, Pramilla D.; Rao, D.D.

    2016-01-01

    Following internal contamination of 32 P, it is preferentially eliminated from the body in urine. It is estimated by in-situ precipitation of ammonium molybdo-phosphate (AMP) in urine followed by gross beta counting. The amount of AMP formed in-situ depends on the amount of stable phosphorous (P) present in the urine and hence, it was essential to generate information regarding urinary excretion of stable P. If amount of P excreted is significant then the amount of AMP formed would correspondingly increase leading to absorption of some of the β particles. The present study was taken up for the estimation of daily urinary excretion of P using the phospho-molybdate spectrophotometry method. Few urine samples received from radiation workers were analyzed and based on the observed range of stable P in urine; volume of sample required for 32 P estimation was finalized

  8. Information sampling behavior with explicit sampling costs

    Science.gov (United States)

    Juni, Mordechai Z.; Gureckis, Todd M.; Maloney, Laurence T.

    2015-01-01

    The decision to gather information should take into account both the value of information and its accrual costs in time, energy and money. Here we explore how people balance the monetary costs and benefits of gathering additional information in a perceptual-motor estimation task. Participants were rewarded for touching a hidden circular target on a touch-screen display. The target’s center coincided with the mean of a circular Gaussian distribution from which participants could sample repeatedly. Each “cue” — sampled one at a time — was plotted as a dot on the display. Participants had to repeatedly decide, after sampling each cue, whether to stop sampling and attempt to touch the hidden target or continue sampling. Each additional cue increased the participants’ probability of successfully touching the hidden target but reduced their potential reward. Two experimental conditions differed in the initial reward associated with touching the hidden target and the fixed cost per cue. For each condition we computed the optimal number of cues that participants should sample, before taking action, to maximize expected gain. Contrary to recent claims that people gather less information than they objectively should before taking action, we found that participants over-sampled in one experimental condition, and did not significantly under- or over-sample in the other. Additionally, while the ideal observer model ignores the current sample dispersion, we found that participants used it to decide whether to stop sampling and take action or continue sampling, a possible consequence of imperfect learning of the underlying population dispersion across trials. PMID:27429991

  9. The migration of drugs-of-abuse from Europe to Denmark – Analysis of pooled anonymous urine from urinals at Roskilde Festival 2016

    DEFF Research Database (Denmark)

    Hoegberg, Lotte Christine Groth; Christiansen, Cecilie; Soe, Jesper

    of NPS, traditional treatment guidelines are challenged. Thus, information of the emergence of new arrivals is of great value. Our knowledge on the actual range of drugs used and NPS available in Denmark is limited as identification is possible only when consumers become patients in the healthcare system...... or through police seizures [2]. We carried out a cross-sectional study of collected pooled anonymous urine, sampled from urinals at the biggest music festival during the year, Roskilde Festival, with the aim to detect classic recreational drugs and NPS. The aim of this study was to identify recreational...... drugs currently used and predict the emergence of NPS by comparing study data with seizure data from the previous year published by EMCDDA [1]. Methods: In total 44 urine samples were collected from three urinals at Roskilde Festival 2016. Two urinals were placed at music stages with late-night concerts...

  10. Estimation of Daily Proteinuria in Patients with Amyloidosis by Using the Protein-To-Creatinine ratio in Random Urine Samples.

    Science.gov (United States)

    Talamo, Giampaolo; Mir Muhammad, A; Pandey, Manoj K; Zhu, Junjia; Creer, Michael H; Malysz, Jozef

    2015-02-11

    Measurement of daily proteinuria in patients with amyloidosis is recommended at the time of diagnosis for assessing renal involvement, and for monitoring disease activity. Renal involvement is usually defined by proteinuria >500 mg/day. We evaluated the accuracy of the random urine protein-to-creatinine ratio (Pr/Cr) in predicting 24 hour proteinuria in patient with amyloidosis. We compared results of random urine Pr/Cr ratio and concomitant 24-hour urine collections in 44 patients with amyloidosis. We found a strong correlation (Spearman's ρ=0.874) between the Pr/Cr ratio and the 24 hour urine protein excretion. For predicting renal involvement, the optimal cut-off point of the Pr/Cr ratio was 715 mg/g. The sensitivity and specificity for this point were 91.8% and 95.5%, respectively, and the area under the curve value was 97.4%. We conclude that the random urine Pr/Cr ratio could be useful in the screening of renal involvement in patients with amyloidosis. If validated in a prospective study, the random urine Pr/Cr ratio could replace the 24 hour urine collection for the assessment of daily proteinuria and presence of nephrotic syndrome in patients with amyloidosis.

  11. Samples and Sampling Protocols for Scientific Investigations | Joel ...

    African Journals Online (AJOL)

    ... from sampling, through sample preparation, calibration to final measurement and reporting. This paper, therefore offers useful information on practical guidance on sampling protocols in line with best practice and international standards. Keywords: Sampling, sampling protocols, chain of custody, analysis, documentation ...

  12. Comparison of Depletion Strategies for the Enrichment of Low-Abundance Proteins in Urine.

    Science.gov (United States)

    Filip, Szymon; Vougas, Konstantinos; Zoidakis, Jerome; Latosinska, Agnieszka; Mullen, William; Spasovski, Goce; Mischak, Harald; Vlahou, Antonia; Jankowski, Joachim

    2015-01-01

    Proteome analysis of complex biological samples for biomarker identification remains challenging, among others due to the extended range of protein concentrations. High-abundance proteins like albumin or IgG of plasma and urine, may interfere with the detection of potential disease biomarkers. Currently, several options are available for the depletion of abundant proteins in plasma. However, the applicability of these methods in urine has not been thoroughly investigated. In this study, we compared different, commercially available immunodepletion and ion-exchange based approaches on urine samples from both healthy subjects and CKD patients, for their reproducibility and efficiency in protein depletion. A starting urine volume of 500 μL was used to simulate conditions of a multi-institutional biomarker discovery study. All depletion approaches showed satisfactory reproducibility (n=5) in protein identification as well as protein abundance. Comparison of the depletion efficiency between the unfractionated and fractionated samples and the different depletion strategies, showed efficient depletion in all cases, with the exception of the ion-exchange kit. The depletion efficiency was found slightly higher in normal than in CKD samples and normal samples yielded more protein identifications than CKD samples when using both initial as well as corresponding depleted fractions. Along these lines, decrease in the amount of albumin and other targets as applicable, following depletion, was observed. Nevertheless, these depletion strategies did not yield a higher number of identifications in neither the urine from normal nor CKD patients. Collectively, when analyzing urine in the context of CKD biomarker identification, no added value of depletion strategies can be observed and analysis of unfractionated starting urine appears to be preferable.

  13. Radioimmunoassay of bleomycin in plasma and urine

    International Nuclear Information System (INIS)

    Teale, J.D.; Clough, J.M.; Marks, V.

    1977-01-01

    Antibodies to bleomycin were raised by immunization of sheep and rabbits with bleomycin-albumin conjugates. The combination of a high-titre, high-avidity sheep antiserum and iodinated bleomycin produced a radioimmunoassay sensitive to 8 ng of bleomycin per ml of plasma or urine. Untreated specimens (100 μl) of plasma or urine could be added directly to the assay tubes. The anti-serum was specific for bleomycin and showed no cross-reaction with other anti-cancer agents used in combination chemotherapy. Over a concentration range of 20 to 100 ng/ml. recovery of bleomycin from plasma was 110% and from urine, 93%. Repeated assay of plasma samples showed a decrease in bleomycin levels unless the samples were kept at 4 0 C or below. Assay of bleomycin levels in plasma and urine from patients under treatment with bleomycin showed similarities with results reported using a microbiological assay. The radioimmunoassay offers a more reliable, rapid and sensitive method for the measurement of bleomycin. (author)

  14. Determination of 2-Octanone in Biological Samples Using Liquid–Liquid Microextractions Followed by Gas Chromatography–Flame Ionization Detectio

    Directory of Open Access Journals (Sweden)

    Abolghasem Jouyban, Maryam Abbaspour, Mir Ali Farajzadeh, Maryam Khoubnasabjafari

    2017-06-01

    Full Text Available Background: Analysis of chemicals in biological fluids is required in many areas of medical sciences. Rapid, highly efficient, and reliable dispersive and air assisted liquid–liquid microextraction methods followed by gas chromatography-flame ionization detection were developed for the extraction, preconcentration, and determination of 2-octanone in human plasma and urine samples. Methods: Proteins of plasma samples are precipitated by adding methanol and urine sample is diluted with water prior to performing the microextraction procedure. Fine organic solvent droplets are formed by repeated suction and injection of the mixture of sample solution and extraction solvent into a test tube with a glass syringe. After extraction, phase separation is performed by centrifuging and the enriched analyte in the sedimented organic phase is determined by the separation system. The main factors influencing the extraction efficiency including extraction solvent type and volume, salt addition, pH, and extraction times are investigated. Results: Under the optimized conditions, the proposed method showed good precision (relative standard deviation less than 7%. Limit of detection and lower limit of quantification for 2-octanone were obtained in the range of 0.1–0.5 µg mL−1. The linear ranges were 0.5-500 and 0.5-200 µg mL−1 in plasma and urine, respectively (r2 ≥ 0.9995. Enrichment factors were in the range of 13-37. Good recoveries (55–86% were obtained for the spiked samples. Conclusion: Preconcentration methods coupled with GC analysis were developed and could be used to monitor 2-octanone in biological samples.

  15. A magnetic bead-based method for concentrating DNA from human urine for downstream detection.

    Directory of Open Access Journals (Sweden)

    Hali Bordelon

    Full Text Available Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pipette bulb to a small diameter tube, and captured biomarkers were concentrated using magnetic entrainment of beads through pre-arrayed wash solutions separated by small air gaps. Feasibility was tested using synthetic segments of the 140 bp tuberculosis IS6110 DNA sequence spiked into pooled human urine samples. DNA recovery was evaluated by qPCR. Despite the presence of spiked DNA, no DNA was detectable in unextracted urine samples, presumably due to the presence of PCR inhibitors. However, following extraction with the magnetic bead-based method, we found that ∼50% of spiked TB DNA was recovered from human urine containing roughly 5×10(3 to 5×10(8 copies of IS6110 DNA. In addition, the DNA was concentrated approximately ten-fold into water. The final concentration of DNA in the eluate was 5×10(6, 14×10(6, and 8×10(6 copies/µL for 1, 3, and 5 mL urine samples, respectively. Lyophilized and freshly prepared reagents within the transfer pipette produced similar results, suggesting that long-term storage without refrigeration is possible. DNA recovery increased with the length of the spiked DNA segments from 10±0.9% for a 75 bp DNA sequence to 42±4% for a 100 bp segment and 58±9% for a 140 bp segment. The estimated LOD was 77 copies of DNA/µL of urine. The strategy presented here provides a simple means to achieve high nucleic acid recovery from easily obtained urine samples, which does not contain inhibitors of PCR.

  16. Influence of storage conditions on aluminum concentrations in serum, dialysis fluid, urine, and tap water.

    Science.gov (United States)

    Wilhelm, M; Ohnesorge, F K

    1990-01-01

    The influence of storage temperature, vessel type, and treatment on alterations of aluminum (Al) concentrations in serum, urine, and dialysis fluid samples was studied at three different concentrations for each sample over an 18-month period. Furthermore, the influence of acidification on Al levels in tap water, urine, and dialysis fluid samples was studied over a four-month period. Al was measured by atomic absorption spectrometry. Sample storage in glass vessels was unsuitable, whereas only minor alterations of Al levels were observed with storage in polypropylene tubes, polystyrene tubes, and Monovettes. By using appropriate plastic containers, acid washing of the vessels showed no improvement. Frozen storage was superior compared with 4 degrees C, whereas storage at -80 degrees C offered no advantage compared with storage at -20 degrees C. Acidification of tap water samples was necessary to stabilize Al levels during storage. No striking effect of acidification on Al levels in urine and dialysis fluid samples was found. It is concluded that longterm storage of serum, urine, tap water, and dialysis fluid samples is possible if appropriate conditions are used.

  17. Electrochemical determination of serotonin in urine samples based on metal oxide nanoparticles/MWCNT on modified glassy carbon electrode

    Directory of Open Access Journals (Sweden)

    Omolola E. Fayemi

    2017-04-01

    Full Text Available The electrochemical response of serotonin on the modified electrode based on multiwalled-carbon-nanotube (MWCNT doped respectively with nickel, zinc and iron oxide nanoparticles coating on glassy carbon electrode (GCE at physiological pH 7 was determined using cyclic voltammetry (CV and square wave voltammetry (SWV. The modified GCE/MWCNT-metal oxide electrodes exhibited excellent electrocatalytic activity towards the detection of serotonin at large peak current and lower oxidation potentials compared to other electrodes investigated. The dynamic range for the serotonin determination was between 5.98 × 10−3 μM to 62.8 μM with detection limits 118, 129 and 166 nM for GCE/MWCNT-NiO, GCE/MWCNT-ZnO and GCE/MWCNT-Fe3O4 sensors respectively. GCE-MWCNT-NiO was the best electrode in terms of serotonin current response, electrode stability, resistance to fouling and limit of detection towards the analyte. The developed sensors were found to be electrochemically stable, reusable, economically effective due to their extremely low operational cost, and have demonstrated good limit of detection, sensitivity and selectivity towards serotonin determination in urine samples. Keywords: Metal oxides nanoparticles, Multiwalled carbon nanotubes, Glassy carbon electrode, Serotonin, Cyclic voltammetry, Square wave voltammetry

  18. Length of time domestic dogs (Canis familiaris) spend smelling urine of gonadectomised and intact conspecifics.

    Science.gov (United States)

    Riach, Anna C; Asquith, Rachel; Fallon, Melissa L D

    2017-09-01

    Domestic dogs (Canis familiaris) use urine to communicate among themselves, however, it is unknown whether the gonadectomy (neutering or spaying) of a dog affects this communication in anyway. Urine samples from 10 intact and 10 gonadectomised, unfamiliar dogs were presented to 12 tester dogs to sniff under controlled conditions in a pilot study. The amount of time the tester dogs spent sniffing each sample was recorded. Overall, tester dogs were recorded smelling the urine of gonadectomised individuals for a longer time. In addition to the type of urine sample, the result is likely to have been influenced by the sex and status (gonadectomised or intact) of the tester dogs. The observed increase in the length of time spent sniffing urine from gonadectomised individuals could be explained by the tester dogs experiencing more difficulty in gaining information from the urine or facing more confusion while analysing the urine compared to the intact urine they have evolved to smell. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Estimation of daily proteinuria in patients with amyloidosis by using the protein-to-creatinine ratio in random urine sample

    Directory of Open Access Journals (Sweden)

    Giampaolo Talamo

    2015-02-01

    Full Text Available Measurement of daily proteinuria in patients with amyloidosis is recommended at the time of diagnosis for assessing renal involvement, and for monitoring disease activity. Renal involvement is usually defined by proteinuria >500 mg/day. We evaluated the accuracy of the random urine protein-to-creatinine ratio (Pr/Cr in predicting 24 hour proteinuria in patient with amyloidosis. We com- pared results of random urine Pr/Cr ratio and concomitant 24-hour urine collections in 44 patients with amyloidosis. We found a strong correlation (Spearman’s ρ=0.874 between the Pr/Cr ratio and the 24 hour urine protein excretion. For predicting renal involvement, the optimal cut-off point of the Pr/Cr ratio was 715 mg/g. The sensitivity and specificity for this point were 91.8% and 95.5%, respectively, and the area under the curve value was 97.4%. We conclude that the random urine Pr/Cr ratio could be useful in the screening of renal involvement in patients with amyloidosis. If validated in a prospective study, the random urine Pr/Cr ratio could replace the 24 hour urine collection for the assessment of daily proteinuria and presence of nephrotic syndrome in patients with amyloidosis.

  20. Effects of processing delay, temperature, and transport tube type on results of quantitative bacterial culture of canine urine.

    Science.gov (United States)

    Patterson, Carly A; Bishop, Micah A; Pack, Julie D; Cook, Audrey K; Lawhon, Sara D

    2016-01-15

    To determine the impact of processing delay, temperature, and transport tube type on results of quantitative bacterial culture (QBC) of canine urine. Diagnostic test evaluation. 60 mL of pooled urine from 4 dogs, divided into six 10-mL aliquots. Urine aliquots were spiked with bacteria from 1 of 6 independent Escherichia coli cultures to achieve a target bacterial concentration of 10(5) CFUs/mL. One milliliter from each aliquot was transferred into 5 silicone-coated clot tubes (SCTs) and 5 urine transport tubes (UTTs). Samples were stored at 4°C (39°F) and 25°C (77°F) for 0, 8, and 24 hours, and then standard QBCs were performed. Median bacterial concentration for urine samples stored in a UTT for 24 hours at 4°C was lower than that for samples stored in an SCT under the same conditions. Conversely, a substantial decrease in median bacterial concentration was identified for samples stored for 24 hours in an SCT at 25°C, compared with the median concentration for samples stored in a UTT under the same conditions. Median bacterial concentration in samples stored in an SCT at 25°C for 24 hours (275 CFUs/mL) was less than the cutoff typically used to define clinically important bacteriuria by use of urine samples obtained via cystocentesis (ie, > 1,000 CFUs/mL). Canine urine samples submitted for immediate QBC should be transported in plain sterile tubes such as SCTs. When prolonged (24-hour) storage at room temperature is anticipated, urine samples should be transported in UTTs.

  1. Absence of bacterial DNA in culture-negative urine from cats with and without lower urinary tract disease.

    Science.gov (United States)

    Lund, Heidi Sjetne; Skogtun, Gaute; Sørum, Henning; Eggertsdóttir, Anna Vigdís

    2015-10-01

    A diagnosis of bacterial cystitis commonly relies on a positive microbiological culture demonstrating the presence of a significant number of colony-forming units/ml urine, as urine within the upper urinary tract, bladder and proximal urethra generally is considered sterile. Recent studies from human and veterinary medicine indicate the presence of non-culturable bacteria in culture-negative urine samples. The aim of the present study was to determine the occurrence of bacterial DNA in culture-negative urine samples from cats with signs of feline lower urinary tract disease (FLUTD) and healthy control cats by 16S ribosomal DNA PCR and subsequent sequencing. The study sample included 38 culture-negative urine samples from cats with FLUTD and 43 culture-negative samples from control cats. Eight culture-positive urine samples from cats with FLUTD were included as external positive controls in addition to negative reaction controls. Of possible methodological limitations, degradation of DNA due to storage, the use of non-sedimented urine for DNA isolation and lack of internal positive reaction controls should be mentioned. The positive controls were recognised, but occurrence of bacterial DNA in culture-negative urine from cats with or without signs of lower urinary tract disease was not demonstrated. However, considering the possible methodological limitations, the presence of bacterial DNA in the urine of culture-negative FLUTD cats cannot be excluded based on the present results alone. Therefore, a prospective study reducing the possibility of degradation of DNA due to storage, in combination with modifications enhancing the chance of detecting even lower levels of bacterial DNA in culture-negative samples, seems warranted. © ISFM and AAFP 2014.

  2. Sampling and chemical analysis in environmental samples around Nuclear Power Plants and some environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Woo; Han, Man Jung; Cho, Seong Won; Cho, Hong Jun; Oh, Hyeon Kyun; Lee, Jeong Min; Chang, Jae Sook [KORTIC, Taejon (Korea, Republic of)

    2002-12-15

    Twelve kinds of environmental samples such as soil, seawater, underground water, etc. around Nuclear Power Plants(NPPs) were collected. Tritium chemical analysis was tried for the samples of rain water, pine-needle, air, seawater, underground water, chinese cabbage, a grain of rice and milk sampled around NPPs, and surface seawater and rain water sampled over the country. Strontium in the soil that sere sampled at 60 point of district in Korea were analyzed. Tritium were sampled at 60 point of district in Korea were analyzed. Tritium were analyzed in 21 samples of surface seawater around the Korea peninsular that were supplied from KFRDI(National Fisheries Research and Development Institute). Sampling and chemical analysis environmental samples around Kori, Woolsung, Youngkwang, Wooljin Npps and Taeduk science town for tritium and strontium analysis was managed according to plans. Succeed to KINS after all samples were tried.

  3. The Use of Chlorhexidine/n-Propyl Gallate (CPG) as an Ambient-Temperature Urine Preservative

    Science.gov (United States)

    Nillen, Jeannie L.; Smith, Scott M.

    2003-01-01

    A safe, effective ambient temperature urine preservative, chlorhexidine/n-propyl gallate (CPG), has been formulated for use during spacefli ght that reduces the effects of oxidation and bacterial contamination on sample integrity while maintaining urine pH. The ability of this preservative to maintain stability of nine key analytes was evaluated for a period of one year. CPG effectively maintained stability of a mmonia, total nitrogen, 3-methylhistidine, chloride, sodium, potassiu m, and urea; however, creatinine and osmolality were not preserved by CPG. These data indicate that CPG offers prolonged room-temperature storage for multiple urine analytes, reducing the requirements for f rozen urine storage on future spaceflights. Iii medical applications on Earth, this technology can allow urine samples to be collected in remote settings and eliminate the need to ship frozen samples.

  4. Study of performance characteristics of a radiochemical method to determine uranium in biological samples

    International Nuclear Information System (INIS)

    Puga, Maria J.; Cerchietti, Maria L.R.; Prudenzo, J.E.; Arguelles, Maria G.

    2005-01-01

    In this paper is described a methodology to calculate detection limit (Ld), quantification level (Lq) and minimum detectable activity (MDA) in a radiochemical method for determination of uranium in urine samples. The concentration is measured by fluorimetry and alpha gross activity using liquid scintillation counting (LSC). The calculation of total propagated uncertainty on a spike sample is presented. Furthermore, the major sources of uncertainty and percentage contribution in both measurements are assessed. (author)

  5. Pierre Gy's sampling theory and sampling practice heterogeneity, sampling correctness, and statistical process control

    CERN Document Server

    Pitard, Francis F

    1993-01-01

    Pierre Gy's Sampling Theory and Sampling Practice, Second Edition is a concise, step-by-step guide for process variability management and methods. Updated and expanded, this new edition provides a comprehensive study of heterogeneity, covering the basic principles of sampling theory and its various applications. It presents many practical examples to allow readers to select appropriate sampling protocols and assess the validity of sampling protocols from others. The variability of dynamic process streams using variography is discussed to help bridge sampling theory with statistical process control. Many descriptions of good sampling devices, as well as descriptions of poor ones, are featured to educate readers on what to look for when purchasing sampling systems. The book uses its accessible, tutorial style to focus on professional selection and use of methods. The book will be a valuable guide for mineral processing engineers; metallurgists; geologists; miners; chemists; environmental scientists; and practit...

  6. Measurement of organically bound tritium in urine and feces

    International Nuclear Information System (INIS)

    Trivedi, A.; Duong, T.; Leon, J.W.; Linauskas, S.H.

    1993-11-01

    A bioassay method was developed for directly measuring organically bound tritium (OBT) in urine and feces. Samples first undergo low-temperature distillation and vacuum separation to isolate tritiated water (HTO) and exchangeable tritium. This is followed by converting the non-exchangeable tritium (i.e., OBT) into HTO through oxygen combustion. The method was investigated to: optimise the sample preparation procedures; establish OBT recovery (64% ± 7% for urine and 71% ± 8% for feces); and, determine the detection limit for OBT in urine (0.3 Bq · g -1 ) and feces (5 Bq · g -1 ). The method was evaluated for error sources that are associated with the exchange between HTO and OBT. It is concluded that this bioassay method can reliably measure OBT in urine and feces within the range of ± 10%

  7. Systematic Sampling and Cluster Sampling of Packet Delays

    OpenAIRE

    Lindh, Thomas

    2006-01-01

    Based on experiences of a traffic flow performance meter this papersuggests and evaluates cluster sampling and systematic sampling as methods toestimate average packet delays. Systematic sampling facilitates for exampletime analysis, frequency analysis and jitter measurements. Cluster samplingwith repeated trains of periodically spaced sampling units separated by randomstarting periods, and systematic sampling are evaluated with respect to accuracyand precision. Packet delay traces have been ...

  8. Validation of protein intake assessed from weighed dietary records against protein estimated from 24 h urine samples in children, adolescents and young adults participating in the Dortmund Nutritional and Longitudinally Designed (DONALD) Study

    DEFF Research Database (Denmark)

    Bokhof, Beate; Günther, Anke L B; Berg-Beckhoff, Gabriele

    2010-01-01

    from a simultaneously collected 24 h urine sample. DESIGN: Cross-sectional analyses including 439 participants of the Dortmund Nutritional and Longitudinally Designed (DONALD) Study from four age groups (3-4, 7-8, 11-13 and 18-23 years). Mean differences, Pearson correlation coefficients (r), cross.......5 (95 % CI -18.7, -8.3) g/d at age 18-23 years. Correlation coefficients were r = 0.7 for the total study sample and ranged from r = 0.5 to 0.6 in the different age groups. Both methods classified 85 % into the same/adjacent quartile for the whole study group (83-86 % for the different age groups) and 2...

  9. Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection

    OpenAIRE

    Jaszczak, Ewa; Ruman, Marek; Narkowicz, Sylwia; Namieśnik, Jacek; Polkowska, Żaneta

    2017-01-01

    A simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1–100 μg/L for urine, 5–100 μg/L for saliva, and 3–100 μg/L for sweat samples with determination coefficients (R) > 0.992. Low detec...

  10. A misleading false-negative result using Neisseria gonorrhoeae opa MGB multiplex PCR assay in patient's rectal sample due to partial mutations of the opa gene.

    Science.gov (United States)

    Vahidnia, Ali; van Empel, Pieter Jan; Costa, Sandra; Oud, Rob T N; van der Straaten, Tahar; Bliekendaal, Harry; Spaargaren, Joke

    2015-07-01

    A 53-year-old homosexual man presented at his general practitioner (GP) practice with a suspicion of sexually transmitted infection. Initial NAAT screening was performed for Chlamydia trachomatis and Neisseria gonorrhoeae. The patient was positive for Neisseria gonorrhoeae both for his urine and rectal sample. The subsequent confirmation test for Neisseria gonorrhoeae by a second laboratory was only confirmed for the urine sample and the rectal sample was negative. We report a case of a potential false-negative diagnosis of Neisseria gonorrhoeae due to mutations of DNA sequence in the probe region of opa-MGB assay of the rectal sample. The patient did not suffer any discomfort as diagnosis of Neisseria gonorrhoeae in his urine sample had already led to treatment by prescribing the patient with Ceftriaxone 500 mg IV dissolved in 1 ml lidocaine 2% and 4 mL saline. The patient also received a prescription for Azithromycin (2x500 mg).

  11. Matrix Metalloproteinase-9/Neutrophil Gelatinase-Associated Lipocalin Complex Activity in Human Glioma Samples Predicts Tumor Presence and Clinical Prognosis

    Directory of Open Access Journals (Sweden)

    Ming-Fa Liu

    2015-01-01

    Full Text Available Matrix metalloproteinase-9/neutrophil gelatinase-associated lipocalin (MMP-9/NGAL complex activity is elevated in brain tumors and may serve as a molecular marker for brain tumors. However, the relationship between MMP-9/NGAL activity in brain tumors and patient prognosis and treatment response remains unclear. Here, we compared the clinical characteristics of glioma patients with the MMP-9/NGAL activity measured in their respective tumor and urine samples. Using gelatin zymography assays, we found that MMP-9/NGAL activity was significantly increased in tumor tissues (TT and preoperative urine samples (Preop-1d urine. Activity was reduced by seven days after surgery (Postop-1w urine and elevated again in cases of tumor recurrence. The MMP-9/NGAL status correlated well with MRI-based tumor assessments. These findings suggest that MMP-9/NGAL activity could be a novel marker to detect gliomas and predict the clinical outcome of patients.

  12. Sampling

    CERN Document Server

    Thompson, Steven K

    2012-01-01

    Praise for the Second Edition "This book has never had a competitor. It is the only book that takes a broad approach to sampling . . . any good personal statistics library should include a copy of this book." —Technometrics "Well-written . . . an excellent book on an important subject. Highly recommended." —Choice "An ideal reference for scientific researchers and other professionals who use sampling." —Zentralblatt Math Features new developments in the field combined with all aspects of obtaining, interpreting, and using sample data Sampling provides an up-to-date treat

  13. Water born pollutants sampling using porous suction samples

    International Nuclear Information System (INIS)

    Baig, M.A.

    1997-01-01

    The common standard method of sampling water born pollutants in the vadoze zone is core sampling and it is followed by extraction of pore fluid. This method does not allow sampling at the same location next time and again later on. There is an alternative approach for sampling fluids (water born pollutants) from both saturated and unsaturated regions of vadose zone using porous suction samplers. There are three types of porous suction samplers, vacuum-operated, pressure-vacuum lysimeters, high pressure vacuum samples. The suction samples are operated in the range of 0-70 centi bars and usually consist of ceramic and polytetrafluorethylene (PTFE). The operation range of PTFE is higher than ceramic cups. These samplers are well suited for in situ and repeated sampling form the same location. This paper discusses the physical properties and operating condition of such samplers to the utilized under our environmental sampling. (author)

  14. Choosing a suitable sample size in descriptive sampling

    International Nuclear Information System (INIS)

    Lee, Yong Kyun; Choi, Dong Hoon; Cha, Kyung Joon

    2010-01-01

    Descriptive sampling (DS) is an alternative to crude Monte Carlo sampling (CMCS) in finding solutions to structural reliability problems. It is known to be an effective sampling method in approximating the distribution of a random variable because it uses the deterministic selection of sample values and their random permutation,. However, because this method is difficult to apply to complex simulations, the sample size is occasionally determined without thorough consideration. Input sample variability may cause the sample size to change between runs, leading to poor simulation results. This paper proposes a numerical method for choosing a suitable sample size for use in DS. Using this method, one can estimate a more accurate probability of failure in a reliability problem while running a minimal number of simulations. The method is then applied to several examples and compared with CMCS and conventional DS to validate its usefulness and efficiency

  15. Comparison of osmolality and refractometric readings of Hispaniolan Amazon parrot (Amazona ventralis) urine.

    Science.gov (United States)

    Brock, A Paige; Grunkemeyer, Vanessa L; Fry, Michael M; Hall, James S; Bartges, Joseph W

    2013-12-01

    To evaluate the relationship between osmolality and specific gravity of urine samples from clinically normal adult parrots and to determine a formula to convert urine specific gravity (USG) measured on a reference scale to a more accurate USG value for an avian species, urine samples were collected opportunistically from a colony of Hispaniolan Amazon parrots (Amazona ventralis). Samples were analyzed by using a veterinary refractometer, and specific gravity was measured on both canine and feline scales. Osmolality was measured by vapor pressure osmometry. Specific gravity and osmolality measurements were highly correlated (r = 0.96). The linear relationship between refractivity measurements on a reference scale and osmolality was determined. An equation was calculated to allow specific gravity results from a medical refractometer to be converted to specific gravity values of Hispaniolan Amazon parrots: USGHAp = 0.201 +0.798(USGref). Use of the reference-canine scale to approximate the osmolality of parrot urine leads to an overestimation of the true osmolality of the sample. In addition, this error increases as the concentration of urine increases. Compared with the human-canine scale, the feline scale provides a closer approximation to urine osmolality of Hispaniolan Amazon parrots but still results in overestimation of osmolality.

  16. A simplified method to recover urinary vesicles for clinical applications, and sample banking.

    Science.gov (United States)

    Musante, Luca; Tataruch, Dorota; Gu, Dongfeng; Benito-Martin, Alberto; Calzaferri, Giulio; Aherne, Sinead; Holthofer, Harry

    2014-12-23

    Urinary extracellular vesicles provide a novel source for valuable biomarkers for kidney and urogenital diseases: Current isolation protocols include laborious, sequential centrifugation steps which hampers their widespread research and clinical use. Furthermore, large individual urine sample volumes or sizable target cohorts are to be processed (e.g. for biobanking), the storage capacity is an additional problem. Thus, alternative methods are necessary to overcome such limitations. We have developed a practical vesicle isolation technique to yield easily manageable sample volumes in an exceptionally cost efficient way to facilitate their full utilization in less privileged environments and maximize the benefit of biobanking. Urinary vesicles were isolated by hydrostatic dialysis with minimal interference of soluble proteins or vesicle loss. Large volumes of urine were concentrated up to 1/100 of original volume and the dialysis step allowed equalization of urine physico-chemical characteristics. Vesicle fractions were found suitable to any applications, including RNA analysis. In the yield, our hydrostatic filtration dialysis system outperforms the conventional ultracentrifugation-based methods and the labour intensive and potentially hazardous step of ultracentrifugations are eliminated. Likewise, the need for trained laboratory personnel and heavy initial investment is avoided. Thus, our method qualifies as a method for laboratories working with urinary vesicles and biobanking.

  17. Reliable laboratory urinalysis results using a new standardised urine collection device

    NARCIS (Netherlands)

    Roelofs-Thijssen, M.A.; Schreuder, M.F.; Hogeveen, M.; Herwaarden, A.E. van

    2013-01-01

    OBJECTIVES: While urine sampling is necessary in the diagnosis of urinary tract infection and electrolyte disturbances, the collection of urine in neonates and non-toilet-trained children is often difficult. A universal urine collection method providing representative urinalyses results is needed.

  18. Level of 90Sr in the urine of a small group of Finnish people

    International Nuclear Information System (INIS)

    Puhakainen, M.; Suomela, M.; Rahola, T.

    1999-01-01

    The aim of the study was to test the feasibility of the applied analysis method for 90 Sr and if possible to estimate the current level of the 90 Sr concentration in the urine. Urine samples were collected from seven Finnish volunteers in connection with studies of 137 Cs body burdens. The activity measurements of urine samples were performed 14 - 18 days after chemical separation of 90 Sr to allow ingrowing of 90 Y. The 90 Sr and 90 Y activities were measured simultaneously using a Quantulus liquid scintillation spectrometer. The detection limit for 90 Sr was 0.0033 Bq per sample, or 0.0007-0.0015 Bq 1 -1 . The 90 Sr activities in urine varied between 0.006 and 0.046 Bq 1 1 . The daily urinary excretion was found to be 0.007-0.018 Bq for the five volunteers that collected three-day urine samples. Assuming that the daily 90 Sr intake was constant and that 18% of the ingested activity was excreted in urine, the mean intake in the investigated group would vary between 0.039 and 0.1 Bq d -1 . Based on these estimated intake values the respective annual effective internal doses from 90 Sr and 90 Y varied from 0.4 to 1 Sv during the sampling period. (au)

  19. Urine Galactomannan-to-Creatinine Ratio for Detection of Invasive Aspergillosis in Patients with Hematological Malignancies.

    Science.gov (United States)

    Reischies, Frederike M J; Raggam, Reinhard B; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin

    2016-03-01

    Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with hematological malignancies. (This study has been registered at ClinicalTrials.gov under registration no. NCT01576653.). Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  20. Manual versus automated streaking system in clinical microbiology laboratory: Performance evaluation of Previ Isola for blood culture and body fluid samples.

    Science.gov (United States)

    Choi, Qute; Kim, Hyun Jin; Kim, Jong Wan; Kwon, Gye Cheol; Koo, Sun Hoe

    2018-01-04

    The process of plate streaking has been automated to improve routine workflow of clinical microbiology laboratories. Although there were many evaluation reports about the inoculation of various body fluid samples, few evaluations have been reported for blood. In this study, we evaluated the performance of automated inoculating system, Previ Isola for various routine clinical samples including blood. Blood culture, body fluid, and urine samples were collected. All samples were inoculated on both sheep blood agar plate (BAP) and MacConkey agar plate (MCK) using Previ Isola and manual method. We compared two methods in aspect of quality and quantity of cultures, and sample processing time. To ensure objective colony counting, an enumeration reading reference was made through a preliminary experiment. A total of 377 nonduplicate samples (102 blood culture, 203 urine, 72 body fluid) were collected and inoculated. The concordance rate of quality was 100%, 97.0%, and 98.6% in blood, urine, and other body fluids, respectively. In quantitative aspect, it was 98.0%, 97.0%, and 95.8%, respectively. The Previ Isola took a little longer to inoculate the specimen than manual method, but the hands-on time decreased dramatically. The shortened hands-on time using Previ Isola was about 6 minutes per 10 samples. We demonstrated that the Previ Isola showed high concordance with the manual method in the inoculation of various body fluids, especially in blood culture sample. The use of Previ Isola in clinical microbiology laboratories is expected to save considerable time and human resources. © 2018 Wiley Periodicals, Inc.

  1. A New Automated Method and Sample Data Flow for Analysis of Volatile Nitrosamines in Human Urine*

    Science.gov (United States)

    Hodgson, James A.; Seyler, Tiffany H.; McGahee, Ernest; Arnstein, Stephen; Wang, Lanqing

    2016-01-01

    Volatile nitrosamines (VNAs) are a group of compounds classified as probable (group 2A) and possible (group 2B) carcinogens in humans. Along with certain foods and contaminated drinking water, VNAs are detected at high levels in tobacco products and in both mainstream and sidestream smoke. Our laboratory monitors six urinary VNAs—N-nitrosodimethylamine (NDMA), N-nitrosomethylethylamine (NMEA), N-nitrosodiethylamine (NDEA), N-nitrosopiperidine (NPIP), N-nitrosopyrrolidine (NPYR), and N-nitrosomorpholine (NMOR)—using isotope dilution GC-MS/MS (QQQ) for large population studies such as the National Health and Nutrition Examination Survey (NHANES). In this paper, we report for the first time a new automated sample preparation method to more efficiently quantitate these VNAs. Automation is done using Hamilton STAR™ and Caliper Staccato™ workstations. This new automated method reduces sample preparation time from 4 hours to 2.5 hours while maintaining precision (inter-run CV < 10%) and accuracy (85% - 111%). More importantly this method increases sample throughput while maintaining a low limit of detection (<10 pg/mL) for all analytes. A streamlined sample data flow was created in parallel to the automated method, in which samples can be tracked from receiving to final LIMs output with minimal human intervention, further minimizing human error in the sample preparation process. This new automated method and the sample data flow are currently applied in bio-monitoring of VNAs in the US non-institutionalized population NHANES 2013-2014 cycle. PMID:26949569

  2. Critical Evaluation of Urine-Based PCR Assay for Diagnosis of Lyme Borreliosis

    OpenAIRE

    Rauter, Carolin; Mueller, Markus; Diterich, Isabel; Zeller, Sabine; Hassler, Dieter; Meergans, Thomas; Hartung, Thomas

    2005-01-01

    Many approaches were made in recent years to establish urine PCR as a diagnostic tool for Lyme borreliosis, but results are contradictory. In the present study, a standardized protocol spiking urine from healthy donors with a defined amount of whole Borrelia or Borrelia DNA was established. The development of a nested real-time PCR targeting ospA enabled a highly sensitive and quantitative analysis of these samples. We show the following. (i) Storage of spiked urine samples for up to 6 months...

  3. Sampling and examination methods used for TMI-2 samples

    International Nuclear Information System (INIS)

    Marley, A.W.; Akers, D.W.; McIsaac, C.V.

    1988-01-01

    The purpose of this paper is to summarize the sampling and examination techniques that were used in the collection and analysis of TMI-2 samples. Samples ranging from auxiliary building air to core debris were collected and analyzed. Handling of the larger samples and many of the smaller samples had to be done remotely and many standard laboratory analytical techniques were modified to accommodate the extremely high radiation fields associated with these samples. The TMI-2 samples presented unique problems with sampling and the laboratory analysis of prior molten fuel debris. 14 refs., 8 figs

  4. Elements concentrations and relationship of whole blood and urine in 40 identical adult men in China

    International Nuclear Information System (INIS)

    Zhu, H.D.; Wu, Q; Fan, T.J.; Liu, Q.F; Wang, J.Y; Wang, N.F; Liu, H.S; Wang, X.Y; Ou-Yang, L.; Liu, Y.Q.; Xie, Q.

    2008-01-01

    Objective: To determine elemental concentrations in whole blood and 24 hr. urine of identical adult men, relative daily urinary excretion and verify relationship between both of concentrations in the blood and urine. Methods: During the same time as sampling organ or tissue samples from autopsy, whole blood and 24 hr. urine samples of identical subjects were obtained from each of 10 healthy adult male volunteers, living in 4 areas with different dietary types in China. The concentrations of 56 elements in both the two kinds of samples were analyzed by using ICP-MS as the principal, assisted with ICP-AES as well GFAAS techniques and necessary QC measures. The concentrations of urinary creatinine in the urine samples were determined by using spectrophotometric method. Results: Concentrations of both the 56 elements in these whole blood and urine samples of identical subjects and urinary creatinine and related daily urinary excretions were obtained. Conclusion: This research obtained the new data on both concentrations of these elements in whole blood and urine samples of identical subjects and their daily urinary excretions for the first time in China. These results have provided preliminary basis for understanding concentrations of these elements in the whole blood, daily urinary excretions of identical subjects as well their differences for different areas, and developing relative background values and parameters for Chinese Reference Man. Furthermore, the obtained results have been compared with both internal and external literature data and discussed. (author)

  5. Internal contamination by natural uranium: monitoring by analysis of urine of individuals exposed by occupational inhalation

    International Nuclear Information System (INIS)

    Ramalho, A.T.

    1982-01-01

    Urine samples from men working at Usina Santo Amaro (USAM - State of Sao Paulo), a monazite refinery, were analysed for uranium concentration, using fluorometric analysis and alpha spectrometry. All samples analysed presented uranium concentration below the lower limit of detection. Theoretical values were calculated for uranium concentration in urine samples from workers at the annual limit of intake (ALI) for inhalation of natural uranium, recommended in Publication 30 of the International Commission on Radiological Protection (ICRP, 1979). The two different methods used for analysis of natural uranium concentration in the urine samples were compared: fluorimetry and alpha spectrometry. (author)

  6. Development and validation of a rapid turboflow LC-MS/MS method for the quantification of LSD and 2-oxo-3-hydroxy LSD in serum and urine samples of emergency toxicological cases.

    Science.gov (United States)

    Dolder, Patrick C; Liechti, Matthias E; Rentsch, Katharina M

    2015-02-01

    Lysergic acid diethylamide (LSD) is a widely used recreational drug. The aim of the present study is to develop a quantitative turboflow LC-MS/MS method that can be used for rapid quantification of LSD and its main metabolite 2-oxo-3-hydroxy LSD (O-H-LSD) in serum and urine in emergency toxicological cases without time-consuming extraction steps. The method was developed on an ion-trap LC-MS/MS instrument coupled to a turbulent-flow extraction system. The validation data showed no significant matrix effects and no ion suppression has been observed in serum and urine. Mean intraday accuracy and precision for LSD were 101 and 6.84%, in urine samples and 97.40 and 5.89% in serum, respectively. For O-H-LSD, the respective values were 97.50 and 4.99% in urine and 107 and 4.70% in serum. Mean interday accuracy and precision for LSD were 100 and 8.26% in urine and 101 and 6.56% in serum, respectively. For O-H-LSD, the respective values were 101 and 8.11% in urine and 99.8 and 8.35% in serum, respectively. The lower limit of quantification for LSD was determined to be 0.1 ng/ml. LSD concentrations in serum were expected to be up to 8 ng/ml. 2-Oxo-3-hydroxy LSD concentrations in urine up to 250 ng/ml. The new method was accurate and precise in the range of expected serum and urine concentrations in patients with a suspected LSD intoxication. Until now, the method has been applied in five cases with suspected LSD intoxication where the intake of the drug has been verified four times with LSD concentrations in serum in the range of 1.80-14.70 ng/ml and once with a LSD concentration of 1.25 ng/ml in urine. In serum of two patients, the O-H-LSD concentration was determined to be 0.99 and 0.45 ng/ml. In the urine of a third patient, the O-H-LSD concentration was 9.70 ng/ml.

  7. Application of bar codes to the automation of analytical sample data collection

    International Nuclear Information System (INIS)

    Jurgensen, H.A.

    1986-01-01

    The Health Protection Department at the Savannah River Plant collects 500 urine samples per day for tritium analyses. Prior to automation, all sample information was compiled manually. Bar code technology was chosen for automating this program because it provides a more accurate, efficient, and inexpensive method for data entry. The system has three major functions: sample labeling is accomplished at remote bar code label stations composed of an Intermec 8220 (Intermec Corp.) interfaced to an IBM-PC, data collection is done on a central VAX 11/730 (Digital Equipment Corp.). Bar code readers are used to log-in samples to be analyzed on liquid scintillation counters. The VAX 11/730 processes the data and generates reports, data storage is on the VAX 11/730 and backed up on the plant's central computer. A brief description of several other bar code applications at the Savannah River Plant is also presented

  8. The Consequence of Delayed Fixation on Subsequent Preservation of Urine Cells

    Directory of Open Access Journals (Sweden)

    Hussain G. Ahmed,

    2011-01-01

    Full Text Available Objectives: Degenerative changes caused by delays in urine preservation contribute to false-negative and false-positive interpretation of urothelial disease in cytology. The aim of this study is to assess whether the delay of fixation of urine samples makes any significant difference to urine cytology and morphology, and the limit of acceptability of delay for routine use in the hospital laboratory.Methods: Three cell collection fluids were evaluated by analyzing the preservation and degeneration of cells in urine samples. In this study, 50 voided urine specimens were taken at random from females complaining of vaginal discharge. Each specimen was divided into three sterile containers. The first was immediately centrifugated and the deposit was smeared onto a cleaned micro slide and immediately fixed into 95�0ethyl alcohol for 15 minutes. The remaining two were prepared in the same manner, however, the second after two hours of collection and the third after four hours of collection. The degree of degeneration and thus the preservation were assessed by a table of chosen criteria, then ranked and analyzed using Friedman's nonparametric test, atp=0.05.Results: The results showed a significant difference between the preservation and the delay in urine fixation, p<0.0001.Conclusion: Any delay in fixation of urine specimen for cytology affects the preservation of cells, which may result in miss diagnosis. It is recommended that urine samples for cytology should be fixed immediately after collection.

  9. Determination of the-230 on urine by means of alpha spectrometry

    International Nuclear Information System (INIS)

    1992-01-01

    The measurements of activity on urine samples are data very important to evaluation the internal doses. We have developed a radiochemistry method with the measure of Th-230 in urine. The method is based in the coprecipitation of the like phosphate the activity of sample is determined by alpha spectrometry. We use like tracer Th-234. The results show a recuperation between 65%-85%

  10. Application of dispersive liquid-liquid microextraction for the preconcentration of eight parabens in real samples and their determination by high-performance liquid chromatography.

    Science.gov (United States)

    Shen, Xiong; Liang, Jian; Zheng, Luxia; Lv, Qianzhou; Wang, Hong

    2017-11-01

    A simple and sensitive method for the simultaneous determination of eight parabens in human plasma and urine samples was developed. The samples were preconcentrated using dispersive liquid-liquid microextraction based on the solidification of floating organic drops and determined by high-performance liquid chromatography with ultraviolet detection. The influence of variables affecting the extraction efficiency was investigated and optimized using Placket-Burman design and Box-Behnken design. The optimized values were: 58 μL of 1-decanol (as extraction solvent), 0.65 mL methanol (as disperser solvent), 1.5% w/v NaCl in 5.0 mL of sample solution, pH 10.6, and 4.0 min centrifugation at 4000 rpm. The extract was injected into the high-performance liquid chromatography system for analysis. Under the optimum conditions, the linear ranges for eight parabens in plasma and urine were 1.0-1000 ng/mL, with correlation coefficients above 0.994. The limit of detection was 0.2-0.4 and 0.1-0.4 ng/mL for plasma and urine samples, respectively. Relative recoveries were between 80.3 and 110.7%, while relative standard deviations were less than 5.4%. Finally, the method was applied to analyze the parabens in 98 patients of primary breast cancer. Results showed that parabens existed widely, at least one paraben detected in 96.9% (95/98) of plasma samples and 98.0% (96/98) of urine samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Sampling and sample processing in pesticide residue analysis.

    Science.gov (United States)

    Lehotay, Steven J; Cook, Jo Marie

    2015-05-13

    Proper sampling and sample processing in pesticide residue analysis of food and soil have always been essential to obtain accurate results, but the subject is becoming a greater concern as approximately 100 mg test portions are being analyzed with automated high-throughput analytical methods by agrochemical industry and contract laboratories. As global food trade and the importance of monitoring increase, the food industry and regulatory laboratories are also considering miniaturized high-throughput methods. In conjunction with a summary of the symposium "Residues in Food and Feed - Going from Macro to Micro: The Future of Sample Processing in Residue Analytical Methods" held at the 13th IUPAC International Congress of Pesticide Chemistry, this is an opportune time to review sampling theory and sample processing for pesticide residue analysis. If collected samples and test portions do not adequately represent the actual lot from which they came and provide meaningful results, then all costs, time, and efforts involved in implementing programs using sophisticated analytical instruments and techniques are wasted and can actually yield misleading results. This paper is designed to briefly review the often-neglected but crucial topic of sample collection and processing and put the issue into perspective for the future of pesticide residue analysis. It also emphasizes that analysts should demonstrate the validity of their sample processing approaches for the analytes/matrices of interest and encourages further studies on sampling and sample mass reduction to produce a test portion.

  12. Boat sampling

    International Nuclear Information System (INIS)

    Citanovic, M.; Bezlaj, H.

    1994-01-01

    This presentation describes essential boat sampling activities: on site boat sampling process optimization and qualification; boat sampling of base material (beltline region); boat sampling of weld material (weld No. 4); problems accompanied with weld crown varieties, RPV shell inner radius tolerance, local corrosion pitting and water clarity. The equipment used for boat sampling is described too. 7 pictures

  13. On-Demand Urine Analyzer

    Science.gov (United States)

    Farquharson, Stuart; Inscore, Frank; Shende, Chetan

    2010-01-01

    A lab-on-a-chip was developed that is capable of extracting biochemical indicators from urine samples and generating their surface-enhanced Raman spectra (SERS) so that the indicators can be quantified and identified. The development was motivated by the need to monitor and assess the effects of extended weightlessness, which include space motion sickness and loss of bone and muscle mass. The results may lead to developments of effective exercise programs and drug regimes that would maintain astronaut health. The analyzer containing the lab-on-a- chip includes materials to extract 3- methylhistidine (a muscle-loss indicator) and Risedronate (a bone-loss indicator) from the urine sample and detect them at the required concentrations using a Raman analyzer. The lab-on- a-chip has both an extractive material and a SERS-active material. The analyzer could be used to monitor the onset of diseases, such as osteoporosis.

  14. Multiplexed Microsphere Suspension-Array Assay for Urine Mitochondrial DNA Typing by C-Stretch Length in Hypervariable Regions.

    Science.gov (United States)

    Aoki, Kimiko; Tanaka, Hiroyuki; Kawahara, Takashi

    2018-07-01

    The standard method for personal identification and verification of urine samples in doping control is short tandem repeat (STR) analysis using nuclear DNA (nDNA). The DNA concentration of urine is very low and decreases under most conditions used for sample storage; therefore, the amount of DNA from cryopreserved urine samples may be insufficient for STR analysis. We aimed to establish a multiplexed assay for urine mitochondrial DNA typing containing only trace amounts of DNA, particularly for Japanese populations. A multiplexed suspension-array assay using oligo-tagged microspheres (Luminex MagPlex-TAG) was developed to measure C-stretch length in hypervariable region 1 (HV1) and 2 (HV2), five single nucleotide polymorphisms (SNPs), and one polymorphic indel. Based on these SNPs and the indel, the Japanese population can be classified into five major haplogroups (D4, B, M7a, A, D5). The assay was applied to DNA samples from urine cryopreserved for 1 - 1.5 years (n = 63) and fresh blood (n = 150). The assay with blood DNA enabled Japanese subjects to be categorized into 62 types, exhibiting a discriminatory power of 0.960. The detection limit for cryopreserved urine was 0.005 ng of nDNA. Profiling of blood and urine pairs revealed that 5 of 63 pairs showed different C-stretch patterns in HV1 or HV2. The assay described here yields valuable information in terms of the verification of urine sample sources employing only trace amounts of recovered DNA. However, blood cannot be used as a reference sample.

  15. A Bayesian Justification for Random Sampling in Sample Survey

    Directory of Open Access Journals (Sweden)

    Glen Meeden

    2012-07-01

    Full Text Available In the usual Bayesian approach to survey sampling the sampling design, plays a minimal role, at best. Although a close relationship between exchangeable prior distributions and simple random sampling has been noted; how to formally integrate simple random sampling into the Bayesian paradigm is not clear. Recently it has been argued that the sampling design can be thought of as part of a Bayesian's prior distribution. We will show here that under this scenario simple random sample can be given a Bayesian justification in survey sampling.

  16. Spectrophotometric Determination of the Trace Amount of Thallium in Water and Urine Samples by Novel Oxidative Coupling Reaction

    Directory of Open Access Journals (Sweden)

    P. Nagaraja

    2009-01-01

    Full Text Available A novel, simple, rapid, sensitive and selective method has been proposed for the trace determination of thallium by spectrophotometric detection. This method is based on the oxidation of MBTH (3-methyl-2-benzothiazolinone hydrazone hydrochloride by thallium(III to form diazonium cation, which couples with IPH (Imipramine hydrochloride in phosphoric acid medium at room temperature giving a blue colored species having a maximum absorption at 635 nm. The reagents and manifold variables influences on the sensitivity were investigated and the optimum reaction conditions have been established. The calibration curve was found to be linear over the range 0.1-5 μg mL-1 with the molar absorptivity and Sandell’s sensitivity of 2.9x104 L mol-1 cm-1, 0.0071 μg cm-2 respectively. The tolerance limit of the method towards various ions usually associated with thallium has been detected. The relative standard deviation for five replicate determination of 2μg mL-1 thallium was 0.47%. The method has been successfully applied for the determination of thallium(ІΙΙ and thallium(I in synthetic, standard reference materials, water and urine samples with satisfactory results. The performance of the proposed method was evaluated in terms of student’s t-test and variance ratio F-test, to find out the significance of proposed method over the reported methods.

  17. Urine Test Strips to Exclude Cerebral Spinal Fluid Blood

    Directory of Open Access Journals (Sweden)

    Marshall, Robin A

    2011-02-01

    Full Text Available Introduction: Determining the presence or absence of red blood cells (RBC or their breakdown products in cerebrospinal fluid (CSF is essential for the evaluation of subarachnoid hemorrhage (SAH in headache patients. Current methodology for finding blood in the CSF is either spectrophotometric detection of pigment, which is time consuming and labor intensive, or visual assesment of samples for color change (xanthochromia, which is inaccurate. Bayer Multistix® urine test strips are designed to test urine for RBC by detecting the presence of hemoglobin. The aim of this pilot study was to evaluate the perfomance of urine reagent test strips for ruling out the presence of RBC in CSF.Methods: We compared color changes on Multistix® urine test strips to the standard of spectrophotometric absorbtion at 415nm and initial RBC counts in 138 visually clear CSF samples.Results: We performed Pearson Chi-Square and likelihood ratios on the results and found a correlation between a negative result on the urine test strip and less than 5 RBC per high power field and a spectrophotometric absorbance of less than 0.02% at 415nm in a CSF sample.Conclusion: These results warrant further investigation in the form of a prospective clinical validation as it may alter the emergency department evaluation for SAH. [West J Emerg Med. 2011;12(1:63-66.

  18. Graph sampling

    OpenAIRE

    Zhang, L.-C.; Patone, M.

    2017-01-01

    We synthesise the existing theory of graph sampling. We propose a formal definition of sampling in finite graphs, and provide a classification of potential graph parameters. We develop a general approach of Horvitz–Thompson estimation to T-stage snowball sampling, and present various reformulations of some common network sampling methods in the literature in terms of the outlined graph sampling theory.

  19. Detection of West Nile virus lineage 2 in the urine of acute human infections.

    Science.gov (United States)

    Papa, Anna; Testa, Theodolinda; Papadopoulou, Elpida

    2014-12-01

    West Nile virus (WNV) lineage 2 emerged in Greece in 2010 and since then outbreaks in humans have been reported for four consecutive years. Laboratory diagnosis is based mainly on serology. A real-time RT-PCR was applied on urine samples obtained from 35 patients with acute WNV infection. WNV RNA was detected in 40% of the samples with cycle threshold (CT) values ranging from 26.95 to 39.89 (mean 33.11). WNV was isolated from two of four urine samples with low CT (sample shipment and storage conditions are very important for virus detection and isolation. The usefulness of the WNV RNA detection in urine as a diagnostic tool of acute WNV infections is discussed. © 2014 Wiley Periodicals, Inc.

  20. Acceptance sampling using judgmental and randomly selected samples

    Energy Technology Data Exchange (ETDEWEB)

    Sego, Landon H.; Shulman, Stanley A.; Anderson, Kevin K.; Wilson, John E.; Pulsipher, Brent A.; Sieber, W. Karl

    2010-09-01

    We present a Bayesian model for acceptance sampling where the population consists of two groups, each with different levels of risk of containing unacceptable items. Expert opinion, or judgment, may be required to distinguish between the high and low-risk groups. Hence, high-risk items are likely to be identifed (and sampled) using expert judgment, while the remaining low-risk items are sampled randomly. We focus on the situation where all observed samples must be acceptable. Consequently, the objective of the statistical inference is to quantify the probability that a large percentage of the unsampled items in the population are also acceptable. We demonstrate that traditional (frequentist) acceptance sampling and simpler Bayesian formulations of the problem are essentially special cases of the proposed model. We explore the properties of the model in detail, and discuss the conditions necessary to ensure that required samples sizes are non-decreasing function of the population size. The method is applicable to a variety of acceptance sampling problems, and, in particular, to environmental sampling where the objective is to demonstrate the safety of reoccupying a remediated facility that has been contaminated with a lethal agent.

  1. A chemiluminescence reagent free method for the determination of captopril in medicine and urine samples by using trivalent silver

    Directory of Open Access Journals (Sweden)

    Zhaofu Fu

    2017-08-01

    Full Text Available A novel flow-injection chemiluminescence (FI-CL method free of CL reagent was developed for the determination of captopril based on its enhancing effect on the CL derived from diperiodatoargentate(III-sulfuric acid system. Compared with the conventional CL system, the CL system based on trivalent silver was characterized of good selectivity for the absence of CL reagent. The CL mechanism was discussed through CL spectra and UV–vis absorption spectra. The conditions of the FI-CL system were investigated and optimized. Under the optimal conditions, the relative CL intensity was linear with the captopril concentration in the range of 0.3–15.0 μg/mL. The detection limit for captopril was 0.05 μg/mL, and the relative standard deviation (n=11 was 2.0% for 5.0 μg/mL captopril. The proposed method was applied to the analysis of captopril in tablet and human urine with the recoveries of 83.1%–112.5%, and the relative standard deviations of 0.5%–4.4%. The results obtained by the proposed method agreed well with those obtained from HPLC method. The proposed method is fast, convenient, and cost-effective for the determination of captopril in medicine and biological samples.

  2. Critical study of common conditions of storage of glucocorticoids and catecholamines in 24-h urine collected during resting and exercising conditions.

    Science.gov (United States)

    Gouarne, C; Foury, A; Duclos, M

    2004-10-01

    Except immediate freezing of the samples, no practical method has been validated for preservation of glucocorticoids and catecholamines in 24-h urine collection. Furthermore, the influence of urine storage at bladder temperature during periods of different lengths and the effect of prior exercise on preservation of these hormones in the bladder have not been investigated until now. Ten healthy volunteers collected their urine both after a resting and after an exercise session. Urine was aliquoted into tubes which were stored during 24 h in the presence or in the absence of preservatives and at different temperatures. Two samples were stored either 3 or 9 h at 37 degrees C (bladder temperature) without additive. When collecting 24-h urine samples for glucocorticoids determination, sample can be stored at room temperature during the 24-h collection period without compromising glucocorticoids preservation. When collecting 24-h urine samples for catecholamines determination, samples have to be chilled without preservative during the whole of the collection period. If the samples have to be stored at room temperature, HCl should be used. Moreover, we report for the first time that catecholamines can be degraded in the bladder and therefore that subjects should urinate every 3 h during either a resting or an exercising day.

  3. Sample collection and preparation of biofluids and extracts for gas chromatography-mass spectrometry.

    Science.gov (United States)

    Emwas, Abdul-Hamid M; Al-Talla, Zeyad A; Kharbatia, Najeh M

    2015-01-01

    To maximize the utility of gas chromatography-mass spectrometry (GC-MS) in metabonomics research, all stages of the experimental design should be standardized, including sample collection, storage, preparation, and sample separation. Moreover, the prerequisite for any GC-MS analysis is that a compound must be volatile and thermally stable if it is to be analyzed using this technique. Since many metabolites are nonvolatile and polar in nature, they are not readily amenable to analysis by GC-MS and require initial chemical derivatization of the polar functional groups in order to reduce the polarity and to increase the thermal stability and volatility of the analytes. In this chapter, an overview is presented of the optimum approach to sample collection, storage, and preparation for gas chromatography-mass spectrometry-based metabonomics with particular focus on urine samples as example of biofluids.

  4. A new method for quasi-reagent-free biomonitoring of mercury in human urine.

    Science.gov (United States)

    Schlathauer, Maria; Reitsam, Verena; Schierl, Rudolf; Leopold, Kerstin

    2017-05-01

    A novel analytical method for sampling and extraction of mercury (Hg) from human urine is presented in this work. The method is based on selective accumulation and separation of Hg from fresh urine sample onto active nanogold-coated silica material by highly efficient solid-phase extraction. After thermal desorption of Hg from the extractant, detection is performed by atomic fluorescence spectrometry (AFS). The feasibility and validity of the optimized, quasi-reagent-free approach was confirmed by recovery experiments in spiked real urine (recovery rate 96.13 ± 5.34%) and by comparison of found Hg concentrations in real urine samples - originating from occupationally exposed persons - with values obtained from reference methods cold vapor - atomic absorption spectrometry (CVAAS) and cold vapor - atomic fluorescence spectrometry (CV-AFS). A very good agreement of the found values reveals the validity of the proposed approach. The limit of detection (LOD) was found to be as low as 0.004 μg Hg L -1 and a high reproducibility with a relative standard deviations ≤4.2% (n = 6) is given. Moreover, storage of the samples for up to one week at an ambient temperature of 30 °C reveals no analyte losses or contamination. In conclusion, the proposed method enables easy-to-handle on-site extraction of total Hg from human urine ensuring at the same time reagent-free sample stabilization, providing quick and safe sampling, which can be performed by untrained persons. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Determination of 1-hydroxypyrene in human urine by high-performance liquid chromatography

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Poulsen, O M; Christensen, J M

    1993-01-01

    A high-performance liquid chromatography (HPLC)/fluorescence method for quantitative analysis of 1-hydroxypyrene in urine was developed. The method validation analysis showed the method to be in analytical control. No significant systematical errors could be demonstrated. The entire run time....... The developed method is presently used for measurement of 1-hydroxypyrene in urine samples from workers exposed to a low airborne level of polycyclic aromatic hydrocarbons, generally less than 25 micrograms/m3. The urine samples of exposed workers (n = 122) showed a range of 1-hydroxypyrene from the limit...

  6. 40 CFR 1065.245 - Sample flow meter for batch sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Sample flow meter for batch sampling... Sample flow meter for batch sampling. (a) Application. Use a sample flow meter to determine sample flow... difference between a diluted exhaust sample flow meter and a dilution air meter to calculate raw exhaust flow...

  7. Generation of induced pluripotent stem cell line (ZZUi011-A from urine sample of a normal human

    Directory of Open Access Journals (Sweden)

    Huifang Sun

    2018-05-01

    Full Text Available Urine cells collected from 200 mL clean midsection urine of a 25-year-old healthy man were reprogrammed into pluripotent stem cells via Sendai virus delivery system. The induced pluripotent stem cells showed a normal karyotype and exhibited the potential to differentiate into three germ layers in a teratoma assay. This cell line may serve as a useful control for comparison with other pluripotent stem cell lines induced from somatic cells of patients with genetic neurodegenerative disorders.

  8. Balanced sampling

    NARCIS (Netherlands)

    Brus, D.J.

    2015-01-01

    In balanced sampling a linear relation between the soil property of interest and one or more covariates with known means is exploited in selecting the sampling locations. Recent developments make this sampling design attractive for statistical soil surveys. This paper introduces balanced sampling

  9. Microbiological test results using three urine pretreatment regimes with 316L stainless steel

    Science.gov (United States)

    Huff, Timothy L.

    1993-01-01

    Three urine pretreatments, (1) Oxone (Dupont) and sulfuric acid, (2) sodium hypochlorite and sulfuric acid, (3) and ozone, were studied for their ability to reduce microbial levels in urine and minimize surface attachment to 316L stainless steel coupons. Urine samples inoculated with Bacillus insolitus and a filamentous mold, organisms previously recovered from the vapor compression distillation subsystem of NASA Space Station Freedom water recovery test were tested in glass corrosion cells containing base or weld metal coupons. Microbial levels, changes in pH, color, turbidity, and odor of the fluid were monitored over the course of the 21-day test. Specimen surfaces were examined by scanning electron microscopy at completion of the test for microbial attachment. Ozonated urine samples were less turbid and had lower microbial levels than controls or samples receiving other pretreatments. Base metal coupons receiving pretreatment were relatively free of attached bacteria. However, well-developed biofilms were found in the heat-affected regions of welded coupons receiving Oxone and hypochlorite pretreatments. Few bacteria were observed in the same regions of the ozone pretreatment sample.

  10. Estimation of uranium in bioassay samples of occupational workers by laser fluorimetry

    International Nuclear Information System (INIS)

    Suja, A.; Prabhu, S.P.; Sawant, P.D.; Sarkar, P.K.; Tiwari, A.K.; Sharma, R.

    2012-01-01

    A newly established uranium processing facility has been commissioned at BARC, Trombay. Monitoring of occupational workers is essential to assess intake of uranium in this facility. A group of 21 workers was selected for bioassay monitoring to assess the existing urinary excretion levels of uranium before the commencement of actual work. Bioassay samples collected from these workers were analyzed by ion-exchange technique followed by laser fluorimetry. Standard addition method was followed for estimation of uranium concentration in the samples. The minimum detectable activity by this technique is about 0.2 ng. The range of uranium observed in these samples varies from 19 to 132 ng/L. Few of these samples were also analyzed by fission track analysis technique and the results were found to be comparable to those obtained by laser fluorimetry. The urinary excretion rate observed for the individual can be regarded as a 'personal baseline' and will be treated as the existing level of uranium in urine for these workers at the facility. (author)

  11. Isotope analytics for the evaluation of the feeding influence on the isotope ratio in beef samples

    International Nuclear Information System (INIS)

    Herwig, Nadine

    2010-01-01

    Information about the origin of food and associated production systems has a high significance for food control. An extremely promising approach to obtain such information is the determination of isotope ratios of different elements. In this study the correlation of the isotope ratios C-13/C-12, N-15/N-14, Mg-25/Mg-24, and Sr-87/Sr-86 in bovine samples (milk and urine) and the corresponding isotope ratios in feed was investigated. It was shown that in the bovine samples all four isotope ratios correlate with the isotope composition of the feed. The isotope ratios of strontium and magnesium have the advantage that they directly reflect the isotope ratios of the ingested feed since there is no isotope fractionation in the bovine organism which is in contrast to the case of carbon and nitrogen isotope ratios. From the present feeding study it is evident, that a feed change leads to a significant change in the delta C-13 values in milk and urine within 10 days already. For the deltaN-15 values the feed change was only visible in the bovine urine after 49 days. Investigations of cows from two different regions (Berlin/Germany and Goestling/Austria) kept at different feeding regimes revealed no differences in the N-15/N-14 and Mg-26/Mg-24 isotope ratios. The strongest correlation between the isotope ratio of the bovine samples and the kind of ingested feed was observed for the carbon isotope ratio. With this ratio even smallest differences in the feed composition were traceable in the bovine samples. Since different regions usually coincide with different feeding regimes, carbon isotope ratios can be used to distinguish bovine samples from different regions if the delta C-13 values of the ingested feed are different. Furthermore, the determination of strontium isotope ratios revealed significant differences between bovine and feed samples of Berlin and Goestling due to the different geologic realities. Hence the carbon and strontium isotope ratios allow the best

  12. Ensemble Sampling

    OpenAIRE

    Lu, Xiuyuan; Van Roy, Benjamin

    2017-01-01

    Thompson sampling has emerged as an effective heuristic for a broad range of online decision problems. In its basic form, the algorithm requires computing and sampling from a posterior distribution over models, which is tractable only for simple special cases. This paper develops ensemble sampling, which aims to approximate Thompson sampling while maintaining tractability even in the face of complex models such as neural networks. Ensemble sampling dramatically expands on the range of applica...

  13. Modern survey sampling

    CERN Document Server

    Chaudhuri, Arijit

    2014-01-01

    Exposure to SamplingAbstract Introduction Concepts of Population, Sample, and SamplingInitial RamificationsAbstract Introduction Sampling Design, Sampling SchemeRandom Numbers and Their Uses in Simple RandomSampling (SRS)Drawing Simple Random Samples with and withoutReplacementEstimation of Mean, Total, Ratio of Totals/Means:Variance and Variance EstimationDetermination of Sample SizesA.2 Appendix to Chapter 2 A.More on Equal Probability Sampling A.Horvitz-Thompson EstimatorA.SufficiencyA.LikelihoodA.Non-Existence Theorem More Intricacies Abstract Introduction Unequal Probability Sampling StrategiesPPS Sampling Exploring Improved WaysAbstract Introduction Stratified Sampling Cluster SamplingMulti-Stage SamplingMulti-Phase Sampling: Ratio and RegressionEstimationviiviii ContentsControlled SamplingModeling Introduction Super-Population ModelingPrediction Approach Model-Assisted Approach Bayesian Methods Spatial SmoothingSampling on Successive Occasions: Panel Rotation Non-Response and Not-at-Homes Weighting Adj...

  14. Impact of urine preservation methods and duration of storage on measured levels of environmental contaminants.

    Science.gov (United States)

    Hoppin, Jane A; Ulmer, Ross; Calafat, Antonia M; Barr, Dana B; Baker, Susan V; Meltzer, Helle M; Rønningen, Kjersti S

    2006-01-01

    Collection of urine samples in human studies involves choices regarding shipping, sample preservation, and storage that may ultimately influence future analysis. As more studies collect and archive urine samples to evaluate environmental exposures in the future, we were interested in assessing the impact of urine preservative, storage temperature, and time since collection on nonpersistent contaminants in urine samples. In spiked urine samples stored in three types of urine vacutainers (no preservative, boric acid, and chlorhexidine), we measured five groups of contaminants to assess the levels of these analytes at five time points (0, 24, 48, and 72 h, and 1 week) and at two temperatures (room temperature and 4 degrees C). The target chemicals were bisphenol A (BPA), metabolites of organophosphate (OP), carbamate, and pyrethroid insecticides, chlorinated phenols, and phthalate monoesters, and were measured using five different mass spectrometry-based methods. Three samples were analyzed at each time point, with the exception of BPA. Repeated measures analysis of variance was used to evaluate effects of storage time, temperature, and preservative. Stability was summarized with percent change in mean concentration from time 0. In general, most analytes were stable under all conditions with changes in mean concentration over time, temperature, and preservative being generally less than 20%, with the exception of the OP metabolites in the presence of boric acid. The effect of storage temperature was less important than time since collection. The precision of the laboratory measurements was high allowing us to observe small differences, which may not be important when categorizing individuals into broader exposure groups.

  15. Respondent-Driven Sampling – Testing Assumptions: Sampling with Replacement

    Directory of Open Access Journals (Sweden)

    Barash Vladimir D.

    2016-03-01

    Full Text Available Classical Respondent-Driven Sampling (RDS estimators are based on a Markov Process model in which sampling occurs with replacement. Given that respondents generally cannot be interviewed more than once, this assumption is counterfactual. We join recent work by Gile and Handcock in exploring the implications of the sampling-with-replacement assumption for bias of RDS estimators. We differ from previous studies in examining a wider range of sampling fractions and in using not only simulations but also formal proofs. One key finding is that RDS estimates are surprisingly stable even in the presence of substantial sampling fractions. Our analyses show that the sampling-with-replacement assumption is a minor contributor to bias for sampling fractions under 40%, and bias is negligible for the 20% or smaller sampling fractions typical of field applications of RDS.

  16. Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks

    Energy Technology Data Exchange (ETDEWEB)

    Nischkauer, Winfried [Institute of Chemical Technologies and Analytics, Vienna University of Technology, Vienna (Austria); Department of Analytical Chemistry, Ghent University, Ghent (Belgium); Vanhaecke, Frank [Department of Analytical Chemistry, Ghent University, Ghent (Belgium); Bernacchi, Sébastien; Herwig, Christoph [Institute of Chemical Engineering, Vienna University of Technology, Vienna (Austria); Limbeck, Andreas, E-mail: Andreas.Limbeck@tuwien.ac.at [Institute of Chemical Technologies and Analytics, Vienna University of Technology, Vienna (Austria)

    2014-11-01

    Nebulising liquid samples and using the aerosol thus obtained for further analysis is the standard method in many current analytical techniques, also with inductively coupled plasma (ICP)-based devices. With such a set-up, quantification via external calibration is usually straightforward for samples with aqueous or close-to-aqueous matrix composition. However, there is a variety of more complex samples. Such samples can be found in medical, biological, technological and industrial contexts and can range from body fluids, like blood or urine, to fuel additives or fermentation broths. Specialized nebulizer systems or careful digestion and dilution are required to tackle such demanding sample matrices. One alternative approach is to convert the liquid into a dried solid and to use laser ablation for sample introduction. Up to now, this approach required the application of internal standards or matrix-adjusted calibration due to matrix effects. In this contribution, we show a way to circumvent these matrix effects while using simple external calibration for quantification. The principle of representative sampling that we propose uses radial line-scans across the dried residue. This compensates for centro-symmetric inhomogeneities typically observed in dried spots. The effectiveness of the proposed sampling strategy is exemplified via the determination of phosphorus in biochemical fermentation media. However, the universal viability of the presented measurement protocol is postulated. Detection limits using laser ablation-ICP-optical emission spectrometry were in the order of 40 μg mL{sup −1} with a reproducibility of 10 % relative standard deviation (n = 4, concentration = 10 times the quantification limit). The reported sensitivity is fit-for-purpose in the biochemical context described here, but could be improved using ICP-mass spectrometry, if future analytical tasks would require it. Trueness of the proposed method was investigated by cross-validation with

  17. Urine sample used for detection of toxoplasma gondii infection by loop-mediated isothermal amplification (LAMP).

    Science.gov (United States)

    Hu, Xin; Pan, Chang-Wang; Li, Ya-Fei; Wang, Han; Tan, Feng

    2012-02-01

    In this study, a loop-mediated isothermal amplification (LAMP) assay was established to detect Toxoplasma gondii DNA in mice infected with T. gondii PRU strain. This LAMP assay was based on the sequence of highly repetitive B1 gene. The detection limit of T. gondii LAMP assay was 1 pg of T. gondii DNA, which was evaluated using 10-fold serially diluted DNA of cultured parasites. The LAMP assay was also highly specific for T. gondii and able to detect T. gondii DNA in urine of mice treated with dexamethasone at 90 day post infection (p.i.), although this assay could not detect the DNA in mice urine 2-6 days p.i. These results demonstrated that LAMP is effective for evaluation of therapy effectiveness for T. gondii infection. The established LAMP assay may represent a useful and practical tool for the routine diagnosis and therapeutic evaluation of human toxoplasmosis.

  18. Determination of Deoxynivalenol in the Urine of Pregnant Women in the UK

    Directory of Open Access Journals (Sweden)

    Liz Wells

    2016-10-01

    Full Text Available Deoxynivalenol (DON is one of the most commonly occurring trichothecenes, produced mainly by Fusarium graminearum. Little is known about the effect of DON exposure or the levels of DON exposure that occur during pregnancy. The project aimed to provide data on levels of total DON and de-epoxi Deoxynivalenol (DOM-1 in pregnant human urine samples analysed by liquid chromatography-mass spectrometry (LC-MS. Morning urine samples were collected over two consecutive days from 42 volunteers and associated food consumption was recorded for the 24 h prior to the sample. Spearman’s rho non-parametric test for correlation was used to assess the data. Levels of DON did not differ significantly between day 1 (mean 29.7 ng/mL urine or 40.1 ng DON/mg creatinine and day 2 (mean 28.7 ng/mL urine or 38.8 ng DON/mg creatinine ng/mL/day urine samples. The only significant positive correlation was found between total ng DON/mg creatinine and parity (rho = 0.307, n = 42, p < 0.005 two-tailed and total ng DON/mg creatinine with baked goods on day 1 (rho = 0.532, n = 42, p < 0.0005 two-tailed. This study provides data on the DON levels in pregnancy in this suburban population and reassurance that those levels are within acceptable limits.

  19. Quantification of Hg excretion and distribution in biological samples of mercury-dental-amalgam users and its correlation with biological variables.

    Science.gov (United States)

    Gul, Nayab; Khan, Sardar; Khan, Abbas; Nawab, Javed; Shamshad, Isha; Yu, Xinwei

    2016-10-01

    This is the first study conducted to quantify the excretion and distribution of mercury (Hg) with time (days) in the biological samples collected from Hg dental amalgam users (MDA). The individuals, with Hg-based dental filling were selected, and their biological samples (red blood cells (RBCs), plasma, urine, hair, and nails) were collected on first, third, and 12th day of fillings. The concentrations of Hg observed in the biological samples of MDA were also correlated with the biological variables such as age, weight, restoration, fish consumption, number, and surface area of fillings. The concentrations of Hg in the biological samples of MDA were found 6-8 times higher than the non-amalgam users (control). The concentrations of Hg in the RBCs (4.39 μg/L), plasma (3.02 μg/L), and urine (22.5 μg/L) on first day of filling were found comparatively higher than the concentrations observed on third day (2.15, 1.46, and 12.3 μg/L for RBCs, plasma, urine, respectively) and 12th day (3.05, 2.5, 9.12 μg/L for RBCs, plasma, urine, respectively), while Hg concentrations were found lower in the hair and nails on third day of fillings (1.53 μg/g for hair and 2.35 μg/g for nails) as compared to the 12th day (2.95 μg/g for hair and 3.5 μg/g for nails). The correlations were found significant (p ˂ 0.05) between Hg concentrations in the biological samples of MDA and biological variables (the number of restoration, fish consumption, number, and surface area of fillings), while no significant (p ˃ 0.05) correlations were observed for Hg concentrations in the biological samples with age and weight of MDA. These observations unveil the fact that the use of Hg-based dental filling is the undesirable exposure to Hg which should be replaced by composite (a safer filling material).

  20. Pre-symptomatic increase in urine-orosomucoid excretion in pre-eclamptic women

    DEFF Research Database (Denmark)

    Kronborg, Camilla Skovhus; Allen, Jim; Vittinghus, Erik

    2007-01-01

    , 32 women developed pre-eclampsia, and 5 controls for every case of pre-eclampsia were found. Blood samples were collected 4 times and urine samples 6 times from the 18/19th week and throughout pregnancy. Orosomucoid and albumin in plasma were analysed by standard methods, and in urine by sandwich...... in orosomucoid. In the plasma samples, orosomucoid was significantly higher late in pre-eclamptic pregnancies (>or=36th week, p=0.0275). CONCLUSIONS: Pre-eclampsia is associated with a pre-symptomatic increase in the urine excretion of orosomucoid, and orosomucoid excretion precedes that of albumin. Orosomucoid...... excretion can probably be used as a prognostic tool in combination with other screening methods, and seems to be a more sensitive marker for evolving pre-eclampsia than albumin. Plasma orosomucoid is significantly increased late in pre-eclampsia. Thus, the increased excretion of orosomucoid must primarily...

  1. Qualitative screening of new psychoactive substances in pooled urine samples from Belgium and United Kingdom

    NARCIS (Netherlands)

    Kinyua, J.; Negreira, N.; Miserez, B.; Causanilles, A.; Gremeaux, L.; Emke, E.; de Voogt, P.; Ramsey, J.; Covaci, A.; van Nuijs, A.L.N.

    2016-01-01

    Concerns about new psychoactive substances (NPS) are increasing due to the rising frequency of serious intoxications. Analysis of biological fluids (urine) is necessary to get reliable information about the use of these substances. However, it is a challenging task due to the lack of analytical

  2. Analysis of urinary neurotransmitters by capillary electrophoresis: Sensitivity enhancement using field-amplified sample injection and molecular imprinted polymer solid phase extraction

    International Nuclear Information System (INIS)

    Claude, Berengere; Nehme, Reine; Morin, Philippe

    2011-01-01

    Highlights: → Field-amplified sample injection (FASI) improves the sensitivity of capillary electrophoresis through the online pre-concentration samples. → The cationic analytes are stacked at the capillary inlet between a zone of low conductivity - sample and pre-injection plug - and a zone of high conductivity - running buffer. → The limits of quantification are 500 times lower than those obtained with hydrodynamic injection. → The presence of salts in the matrix greatly reduces the sensitivity of the FASI/CE-UV method. - Abstract: Capillary electrophoresis (CE) has been investigated for the analysis of some neurotransmitters, dopamine (DA), 3-methoxytyramine (3-MT) and serotonin (5-hydroxytryptamine, 5-HT) at nanomolar concentrations in urine. Field-amplified sample injection (FASI) has been used to improve the sensitivity through the online pre-concentration samples. The cationic analytes were stacked at the capillary inlet between a zone of low conductivity - sample and pre-injection plug - and a zone of high conductivity - running buffer. Several FASI parameters have been optimized (ionic strength of the running buffer, concentration of the sample protonation agent, composition of the sample solvent and nature of the pre-injection plug). Best results were obtained using H 3 PO 4 -LiOH (pH 4, ionic strength of 80 mmol L -1 ) as running buffer, 100 μmol L -1 of H 3 PO 4 in methanol-water 90/10 (v/v) as sample solvent and 100 μmol L -1 of H 3 PO 4 in water for the pre-injection plug. In these conditions, the linearity was verified in the 50-300 nmol L -1 concentration range for DA, 3-MT and 5-HT with a determination coefficient (r 2 ) higher than 0.99. The limits of quantification (10 nmol L -1 for DA and 3-MT, 5.9 nmol L -1 for 5-HT) were 500 times lower than those obtained with hydrodynamic injection. However, if this method is applied to the analysis of neurotransmitters in urine, the presence of salts in the matrix greatly reduces the sensitivity

  3. Analysis of urinary neurotransmitters by capillary electrophoresis: Sensitivity enhancement using field-amplified sample injection and molecular imprinted polymer solid phase extraction

    Energy Technology Data Exchange (ETDEWEB)

    Claude, Berengere, E-mail: berengere.claude@univ-orleans.fr [Institut de Chimie Organique et Analytique, CNRS FR 2708 UMR 6005, Universite d' Orleans, 45067 Orleans (France); Nehme, Reine; Morin, Philippe [Institut de Chimie Organique et Analytique, CNRS FR 2708 UMR 6005, Universite d' Orleans, 45067 Orleans (France)

    2011-08-12

    Highlights: {yields} Field-amplified sample injection (FASI) improves the sensitivity of capillary electrophoresis through the online pre-concentration samples. {yields} The cationic analytes are stacked at the capillary inlet between a zone of low conductivity - sample and pre-injection plug - and a zone of high conductivity - running buffer. {yields} The limits of quantification are 500 times lower than those obtained with hydrodynamic injection. {yields} The presence of salts in the matrix greatly reduces the sensitivity of the FASI/CE-UV method. - Abstract: Capillary electrophoresis (CE) has been investigated for the analysis of some neurotransmitters, dopamine (DA), 3-methoxytyramine (3-MT) and serotonin (5-hydroxytryptamine, 5-HT) at nanomolar concentrations in urine. Field-amplified sample injection (FASI) has been used to improve the sensitivity through the online pre-concentration samples. The cationic analytes were stacked at the capillary inlet between a zone of low conductivity - sample and pre-injection plug - and a zone of high conductivity - running buffer. Several FASI parameters have been optimized (ionic strength of the running buffer, concentration of the sample protonation agent, composition of the sample solvent and nature of the pre-injection plug). Best results were obtained using H{sub 3}PO{sub 4}-LiOH (pH 4, ionic strength of 80 mmol L{sup -1}) as running buffer, 100 {mu}mol L{sup -1} of H{sub 3}PO{sub 4} in methanol-water 90/10 (v/v) as sample solvent and 100 {mu}mol L{sup -1} of H{sub 3}PO{sub 4} in water for the pre-injection plug. In these conditions, the linearity was verified in the 50-300 nmol L{sup -1} concentration range for DA, 3-MT and 5-HT with a determination coefficient (r{sup 2}) higher than 0.99. The limits of quantification (10 nmol L{sup -1} for DA and 3-MT, 5.9 nmol L{sup -1} for 5-HT) were 500 times lower than those obtained with hydrodynamic injection. However, if this method is applied to the analysis of

  4. Comparison of sodium, potassium, calcium, magnesium, zinc, copper and iron concentrations of elements in 24-h urine and spot urine in hypertensive patients with healthy renal function.

    Science.gov (United States)

    Zhang, Tianjing; Chang, Xiaoyu; Liu, Wanlu; Li, Xiaoxia; Wang, Faxuan; Huang, Liping; Liao, Sha; Liu, Xiuying; Zhang, Yuhong; Zhao, Yi

    2017-12-01

    Sodium, potassium, calcium, magnesium, zinc, copper and iron are associated with the sequela of hypertension. The most reliable method for testing those elements is by collecting 24-h urine samples. However, this is cumbersome and collection of spot urine is more convenient in some circumstance. The aim of this study was to compare the concentrations of different elements in 24-h urine and spot urine. Data was collected from a sub-study of China Salt Substitute and Stroke Study. 240 participants were recruited randomly from 12 villages in two counties in Ningxia, China. Both spot and 24-h urine specimens were collected from each patient. Routine urine test was conducted, and concentration of elements was measured using microwave digestion and Inductively Coupled Plasma-Optical Emission Spectrometry. Partial correlation analysis and Spearman correlation analysis were used to investigate the concentration of different elements and the relationship between 24- h urine and spot urine. A partial correlation in sodium, potassium, calcium, magnesium and iron was found between paired 24-h urine and spot urine samples except copper and zinc: 0.430, 0.426, 0.550, 0.221 and 0.191 respectively. Spot urine can replace 24-h urine for estimating some of the elements in hypertensive patients with normal renal function. Copyright © 2017 Elsevier GmbH. All rights reserved.

  5. High performance of a new PCR-based urine assay for HPV-DNA detection and genotyping.

    Science.gov (United States)

    Tanzi, Elisabetta; Bianchi, Silvia; Fasolo, Maria Michela; Frati, Elena R; Mazza, Francesca; Martinelli, Marianna; Colzani, Daniela; Beretta, Rosangela; Zappa, Alessandra; Orlando, Giovanna

    2013-01-01

    Human papillomavirus (HPV) testing has been proposed as a means of replacing or supporting conventional cervical screening (Pap test). However, both methods require the collection of cervical samples. Urine sample is easier and more acceptable to collect and could be helpful in facilitating cervical cancer screening. The aim of this study was to evaluate the sensitivity and specificity of urine testing compared to conventional cervical smear testing using a PCR-based method with a new, designed specifically primer set. Paired cervical and first voided urine samples collected from 107 women infected with HIV were subjected to HPV-DNA detection and genotyping using a PCR-based assay and a restriction fragment length polymorphism method. Sensitivity, specificity, Positive Predictive Value (PPV), and Negative Predictive Value (NPV) were calculated using the McNemar's test for differences. Concordance between tests was assessed using the Cohen's unweighted Kappa (k). HPV DNA was detected in 64.5% (95% CI: 55.1-73.1%) of both cytobrush and urine samples. High concordance rates of HPV-DNA detection (k = 0.96; 95% CI: 0.90-1.0) and of high risk-clade and low-risk genotyping in paired samples (k = 0.80; 95% CI: 0.67-0.92 and k = 0.74; 95% CI: 0.60-0.88, respectively) were observed. HPV-DNA detection in urine versus cervix testing revealed a sensitivity of 98.6% (95% CI: 93.1-99.9%) and a specificity of 97.4% (95% CI: 87.7-99.9%), with a very high NPV (97.4%; 95% CI: 87.7-99.9%). The PCR-based assay utilized in this study proved highly sensitive and specific for HPV-DNA detection and genotyping in urine samples. These data suggest that a urine-based assay would be a suitable and effective tool for epidemiological surveillance and, most of all, screening programs. Copyright © 2012 Wiley Periodicals, Inc.

  6. Identification of microRNAs in blood and urine as tumour markers for the detection of urinary bladder cancer.

    Science.gov (United States)

    Tölle, Angelika; Jung, Monika; Rabenhorst, Silke; Kilic, Ergin; Jung, Klaus; Weikert, Steffen

    2013-10-01

    Since differential expression of microRNAs (miRNAs) has been found to be highly associated with several types of cancer, the goal of the present study was to identify an miRNA fingerprint as a non‑invasive diagnostic tool to detect urinary bladder cancer using the easily accessible samples of whole blood and urine. Blood and urine samples from 4 controls and from patients suffering from superficial and invasive bladder cancer were analyzed using miRNA microarray consisting of 754 human miRNAs from the Sanger database v14. Using RT‑qPCR technique, 6 of the differentially expressed miRNAs were validated in the controls (20 blood, 19 urine samples) and patients with superficial (18 blood, 16 urine samples) or invasive (20 blood and urine samples each) tumours. Three blood miRNAs (miR‑26b‑5p, miR‑144‑5p, miR‑374‑5p) were found to be significantly upregulated in invasive bladder tumour patients (Pbladder tumours with 94% specificity and 65% sensitivity. The urine miR‑1255b‑5p reached 68% specificity and 85% sensitivity in the diagnosis of invasive tumours. This pilot study represents the first characterization of an miRNA profile for urinary bladder tumours in whole blood samples. In addition, it was shown that invasive bladder tumours could be identified by differentially expressed urine miRNAs. Further studies are needed to test the clinical usefulness for bladder cancer detection and surveillance.

  7. Sample preparation for liquid chromatographic analysis of phytochemicals in biological fluids.

    Science.gov (United States)

    Oh, Ju-Hee; Lee, Young-Joo

    2014-01-01

    Natural products have been used traditionally for the treatment and prevention of diseases for thousands of years and are nowadays consumed as dietary supplements and herbal medicine. To ensure the safe and effective use of these herbal products, information about bioavailability of active compounds in plasma or target tissues should be provided via validated analytical methods combined with appropriate sampling methods. To provide comprehensive and abridged information about sample preparation methods for the quantification of phytochemicals in biological samples using liquid chromatography analysis. Sample pre-treatment procedures used in analytical methods for in vivo pharmacokinetic studies of natural compounds or herbal medicines were reviewed. These were categorised according to the biological matrices (plasma, bile, urine, faeces and tissues) and sample clean-up processes (protein precipitation, liquid-liquid extraction and solid-phase extraction). Although various kinds of sample pre-treatment methods have been developed, liquid-liquid extraction is still widely used and solid-phase extraction is becoming increasingly popular because of its efficiency for extensive clean up of complex matrix samples. However, protein precipitation is still favoured due to its simplicity. Sample treatment for phytochemical analysis in biological fluids is an indispensable and critical step to obtain high quality results. This step could dominate the overall analytical process because both the duration of the process as well as the reliability of the data depend in large part on its efficiency. Thus, special attention should be given to the choice of a proper sample treatment method that targets analytes and their biomatrix. Copyright © 2013 John Wiley & Sons, Ltd.

  8. Sample preparation

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Sample preparation prior to HPLC analysis is certainly one of the most important steps to consider in trace or ultratrace analysis. For many years scientists have tried to simplify the sample preparation process. It is rarely possible to inject a neat liquid sample or a sample where preparation may not be any more complex than dissolution of the sample in a given solvent. The last process alone can remove insoluble materials, which is especially helpful with the samples in complex matrices if other interactions do not affect extraction. Here, it is very likely a large number of components will not dissolve and are, therefore, eliminated by a simple filtration process. In most cases, the process of sample preparation is not as simple as dissolution of the component interest. At times, enrichment is necessary, that is, the component of interest is present in very large volume or mass of material. It needs to be concentrated in some manner so a small volume of the concentrated or enriched sample can be injected into HPLC. 88 refs

  9. A sensitive determination of terbutaline in pharmaceuticals and urine samples using a composite electrode based on zirconium oxide nanoparticles

    International Nuclear Information System (INIS)

    Baytak, Aysegul Kutluay; Teker, Tugce; Duzmen, Sehriban; Aslanoglu, Mehmet

    2016-01-01

    An accurate and precise determination of terbutaline has been carried out using a glassy carbon electrode (GCE) modified with a composite of multi-walled carbon nanotubes (MWCNTs) and nanoparticles of zirconium oxide (ZrO_2NPs). Energy dispersive X-ray and scanning electron microscopic techniques were utilized for the characterization of the composite layer. Terbutaline exhibited a broad oxidation peak at 770 mV on a GCE. However, MWCNTs/GCE presented an electrocatalytic effect toward the oxidation of terbutaline with a better anodic peak at 660 mV. Furthermore, the electrochemical behavior of terbutaline has greatly been improved at a GCE modified with a composite of MWCNTs and nanoparticles of ZrO_2. The ZrO_2NPs/MWCNTs/GCE exhibited a sharp anodic wave at 645 mV with a large enhancement of the current response for terbutaline. Square wave voltammetry (SWV) was performed for the determination of terbutaline at ZrO_2NPs/MWCNTs/GCE. A linear plot was obtained for the current responses of terbutaline against concentrations in the range of 10–160 nM yielding a detection limit of 2.25 nM (based on 3S_b/m). Improved voltammetric behavior, long-time stability and good reproducibility were obtained for terbutaline at the proposed electrode. A mean recovery of 101.2% with an RSD% of 1.9 was obtained for the analysis of the drug formulation. The accurate and precise quantification of terbutaline makes the ZrO_2NPs/MWCNTs/GCE system of great interest for monitoring its therapeutic use. - Graphical abstract: A sensitive determination of terbutaline in pharmaceuticals and urine samples using a composite electrode based on zirconium oxide nanoparticles. Display Omitted - Highlights: • A composite electrode was prepared using nanoparticles of ZrO_2 and MWCNTs. • The ZrO_2NPs/MWCNTs/GCE has greatly improved the voltammetry of terbutaline • The proposed electrode enabled a detection limit of 2.25 nM. • The proposed electrode exhibited good reproducibility and long

  10. Fluctuations of nickel concentrations in urine of electroplating workers

    International Nuclear Information System (INIS)

    Bernacki, E.J.; Zygowicz, E.; Sunderman, F.W. Jr.

    1980-01-01

    Nickel analyses were performed by electrothermal atomic absorption spectrometry upon urine specimens obtained from electroplating workers at the beginning, middle and end of the work-shift. The means (+- S.D.) for nickel concentrations in urine specimens from seven electroplating workers on three regular workdays were: 34 +- 32 μg/L (pre-shift); 64 +- μg/L (mid-shift) and 46 +- μg/L (end-shift), compared to 2.7 +- 1.6 μg/L (pre-shift) in 19 controls (hospital workers). Nickel concentrations in urine specimens from six electroplating workers on the first workday after a two-week vacation averaged: 5 +- 3 μg/L (pre-shift); 9 +- 6 μg/L (mid-shift), and 12 +- 6 μg/L (end-shift). Nickel concentrations in personal air samples (seven hours) collected from the breathing zones of five electroplating workers on three regular workdays averaged 9.3 +- 4.4 μg/m 3 . Nickel concentrations in the air samples were correlated with nickel concentrations in end-shift urine specimens (corr. coef. = 0.70; P < 0.05), but were not correlated with nickel concentrations in pre-shift or mid-shift urine specimens. In view of the fluctuations of urine nickel concentrations that occur during the work-shift, the authors recommend that nickel analyses of eight hour urine specimens be used routinely to monitor occupational exposures to nickel. In situations where timed urine collections are impractical, analyses of end-shift urine specimens are the best alternative

  11. Determination of radium in urine; Dosage du radium dans l'urine

    Energy Technology Data Exchange (ETDEWEB)

    Fourniguet, H; Jeanmaire, L; Jammet, H [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    A procedure for the quantitative analysis of radium in urine is described. The radium is carried by a barium sulfate precipitate. The precipitate is mixed with zinc sulfide and the activity measured by scintillation counting. It is thus possible to detect an amount of radium less than 1 pico-curie in the sample. (author) [French] Cet article decrit une technique de dosage du radium dans l'urine. Le radium entraine par un precipite de sulfate de baryum est compte par scintillation apres melange du precipite avec du sulfure de zinc. Cette methode permet de deceler moins de 1 picocurie de radium dans l'echantillon. (auteur)

  12. Uranium analysis in urine by inductively coupled plasma dynamic reaction cell mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ejnik, John W. [Northern Michigan University, Chemistry Department, Marquette, MI (United States); Todorov, Todor I.; Mullick, Florabel G.; Centeno, Jose A. [Armed Forces Institute of Pathology (AFIP), Division of Biophysical Toxicology, Washington, DC (United States); Squibb, Katherine; McDiarmid, Melissa A. [University of Maryland, School of Medicine, Baltimore, MD (United States)

    2005-05-01

    Urine uranium concentrations are the best biological indicator for identifying exposure to depleted uranium (DU). Internal exposure to DU causes an increased amount of urine uranium and a decreased ratio of {sup 235}U/{sup 238}U in urine samples, resulting in measurements that vary between 0.00725 and 0.002 (i.e., natural and depleted uranium's {sup 235}U/{sup 238}U ratios, respectively). A method based on inductively coupled plasma dynamic reaction cell mass spectrometry (ICP-DRC-MS) was utilized to identify DU in urine by measuring the quantity of total U and the {sup 235}U/{sup 238}U ratio. The quantitative analysis was achieved using {sup 233}U as an internal standard. The analysis was performed both with and without the reaction gas oxygen. The reaction gas converted ionized {sup 235}U{sup +} and {sup 238}U{sup +} into {sup 235}UO{sub 2}{sup +} (m/z=267) and {sup 238}UO{sub 2}{sup +} (m/z=270). This conversion was determined to be over 90% efficient. A polyatomic interference at m/z 234.8 was successfully removed from the {sup 235}U signal under either DRC operating conditions (with or without oxygen as a reaction gas). The method was validated with 15 urine samples of known uranium compositions. The method detection limit for quantification was determined to be 0.1 pg U mL{sup -1} urine and an average coefficient of variation (CV) of 1-2% within the sample measurements. The method detection limit for determining {sup 235}U/{sup 238}U ratio was 3.0 pg U mL{sup -1} urine. An additional 21 patient samples were analyzed with no information about medical history. The measured {sup 235}U/{sup 238}U ratio within the urine samples correctly identified the presence or absence of internal DU exposure in all 21 patients. (orig.)

  13. Comparison of overnight, morning and 24-hour urine collections in the assessment of diabetic microalbuminuria

    DEFF Research Database (Denmark)

    Eshøj, O; Feldt-Rasmussen, B; Larsen, M L

    1987-01-01

    With the aim of comparing different urine collection periods in the assessment of micro-albuminuria, urinary albumin excretion rates (AERs) were measured in samples from 24 h, overnight, and morning urine collections in 54 patients aged 17 to 62 years with insulin-dependent diabetes mellitus...... overnight and morning urine samples. These values were slightly improved by relating AER to the excretion of creatinine and it is concluded that overnight as well as morning urine collections can be used when diagnosing microalbuminuria in insulin-dependent diabetics. Furthermore the results show...

  14. Sample summary report for ARG 1 pressure tube sample

    International Nuclear Information System (INIS)

    Belinco, C.

    2006-01-01

    The ARG 1 sample is made from an un-irradiated Zr-2.5% Nb pressure tube. The sample has 103.4 mm ID, 112 mm OD and approximately 500 mm length. A punch mark was made very close to one end of the sample. The punch mark indicates the 12 O'clock position and also identifies the face of the tube for making all the measurements. ARG 1 sample contains flaws on ID and OD surface. There was no intentional flaw within the wall of the pressure tube sample. Once the flaws are machined the pressure tube sample was covered from outside to hide the OD flaws. Approximately 50 mm length of pressure tube was left open at both the ends to facilitate the holding of sample in the fixtures for inspection. No flaw was machined in this zone of 50 mm on either end of the pressure tube sample. A total of 20 flaws were machined in ARG 1 sample. Out of these, 16 flaws were on the OD surface and the remaining 4 on the ID surface of the pressure tube. The flaws were characterized in to various groups like axial flaws, circumferential flaws, etc

  15. Prions in the Urine of Patients with Variant Creutzfeldt–Jakob Disease

    Science.gov (United States)

    Moda, Fabio; Gambetti, Pierluigi; Notari, Silvio; Concha-Marambio, Luis; Catania, Marcella; Park, Kyung-Won; Maderna, Emanuela; Suardi, Silvia; Haïk, Stéphane; Brandel, Jean-Philippe; Ironside, James; Knight, Richard; Tagliavini, Fabrizio; Soto, Claudio

    2014-01-01

    BACKGROUND Prions, the infectious agents responsible for transmissible spongiform encephalopathies, consist mainly of the misfolded prion protein (PrPSc). The unique mechanism of transmission and the appearance of a variant form of Creutzfeldt–Jakob disease, which has been linked to consumption of prion-contaminated cattle meat, have raised concerns about public health. Evidence suggests that variant Creutzfeldt–Jakob disease prions circulate in body fluids from people in whom the disease is silently incubating. METHODS To investigate whether PrPSc can be detected in the urine of patients with variant Creutzfeldt–Jakob disease, we used the protein misfolding cyclic amplification (PMCA) technique to amplify minute quantities of PrPSc, enabling highly sensitive detection of the protein. We analyzed urine samples from several patients with various transmissible spongiform encephalopathies (variant and sporadic Creutzfeldt–Jakob disease and genetic forms of prion disease), patients with other degenerative or nondegenerative neurologic disorders, and healthy persons. RESULTS PrPSc was detectable only in the urine of patients with variant Creutzfeldt–Jakob disease and had the typical electrophoretic profile associated with this disease. PrPSc was detected in 13 of 14 urine samples obtained from patients with variant Creutzfeldt–Jakob disease and in none of the 224 urine samples obtained from patients with other neurologic diseases and from healthy controls, resulting in an estimated sensitivity of 92.9% (95% confidence interval [CI], 66.1 to 99.8) and a specificity of 100.0% (95% CI, 98.4 to 100.0). The PrPSc concentration in urine calculated by means of quantitative PMCA was estimated at 1×10−16 g per milliliter, or 3×10−21 mol per milliliter, which extrapolates to approximately 40 to 100 oligomeric particles of PrPSc per milliliter of urine. CONCLUSIONS Urine samples obtained from patients with variant Creutzfeldt–Jakob disease contained minute

  16. Prions in the urine of patients with variant Creutzfeldt-Jakob disease.

    Science.gov (United States)

    Moda, Fabio; Gambetti, Pierluigi; Notari, Silvio; Concha-Marambio, Luis; Catania, Marcella; Park, Kyung-Won; Maderna, Emanuela; Suardi, Silvia; Haïk, Stéphane; Brandel, Jean-Philippe; Ironside, James; Knight, Richard; Tagliavini, Fabrizio; Soto, Claudio

    2014-08-07

    Prions, the infectious agents responsible for transmissible spongiform encephalopathies, consist mainly of the misfolded prion protein (PrP(Sc)). The unique mechanism of transmission and the appearance of a variant form of Creutzfeldt-Jakob disease, which has been linked to consumption of prion-contaminated cattle meat, have raised concerns about public health. Evidence suggests that variant Creutzfeldt-Jakob disease prions circulate in body fluids from people in whom the disease is silently incubating. To investigate whether PrP(Sc) can be detected in the urine of patients with variant Creutzfeldt-Jakob disease, we used the protein misfolding cyclic amplification (PMCA) technique to amplify minute quantities of PrP(Sc), enabling highly sensitive detection of the protein. We analyzed urine samples from several patients with various transmissible spongiform encephalopathies (variant and sporadic Creutzfeldt-Jakob disease and genetic forms of prion disease), patients with other degenerative or nondegenerative neurologic disorders, and healthy persons. PrP(Sc) was detectable only in the urine of patients with variant Creutzfeldt-Jakob disease and had the typical electrophoretic profile associated with this disease. PrP(Sc) was detected in 13 of 14 urine samples obtained from patients with variant Creutzfeldt-Jakob disease and in none of the 224 urine samples obtained from patients with other neurologic diseases and from healthy controls, resulting in an estimated sensitivity of 92.9% (95% confidence interval [CI], 66.1 to 99.8) and a specificity of 100.0% (95% CI, 98.4 to 100.0). The PrP(Sc) concentration in urine calculated by means of quantitative PMCA was estimated at 1×10(-16) g per milliliter, or 3×10(-21) mol per milliliter, which extrapolates to approximately 40 to 100 oligomeric particles of PrP(Sc) per milliliter of urine. Urine samples obtained from patients with variant Creutzfeldt-Jakob disease contained minute quantities of PrP(Sc). (Funded by the

  17. Preparation of Biological Samples Containing Metoprolol and Bisoprolol for Applying Methods for Quantitative Analysis

    Directory of Open Access Journals (Sweden)

    Corina Mahu Ştefania

    2015-12-01

    Full Text Available Arterial hypertension is a complex disease with many serious complications, representing a leading cause of mortality. Selective beta-blockers such as metoprolol and bisoprolol are frequently used in the management of hypertension. Numerous analytical methods have been developed for the determination of these substances in biological fluids, such as liquid chromatography coupled with mass spectrometry, gas chromatography coupled with mass spectrometry, high performance liquid chromatography. Due to the complex composition of biological fluids a biological sample pre-treatment before the use of the method for quantitative determination is required in order to remove proteins and potential interferences. The most commonly used methods for processing biological samples containing metoprolol and bisoprolol were identified through a thorough literature search using PubMed, ScienceDirect, and Willey Journals databases. Articles published between years 2005-2015 were reviewed. Protein precipitation, liquid-liquid extraction and solid phase extraction are the main techniques for the extraction of these drugs from plasma, serum, whole blood and urine samples. In addition, numerous other techniques have been developed for the preparation of biological samples, such as dispersive liquid-liquid microextraction, carrier-mediated liquid phase microextraction, hollow fiber-protected liquid phase microextraction, on-line molecularly imprinted solid phase extraction. The analysis of metoprolol and bisoprolol in human plasma, urine and other biological fluids provides important information in clinical and toxicological trials, thus requiring the application of appropriate extraction techniques for the detection of these antihypertensive substances at nanogram and picogram levels.

  18. Radioimmunoassay screening and GC/MS confirmation of whole blood samples for drugs of abuse

    Energy Technology Data Exchange (ETDEWEB)

    Spiehler, V.R.; Sedgwick, P.

    From 1981 to 1984, an average of 300 radioimmunoassay screens on whole blood were performed each week in the authors laboratory. Most samples were screened for opiates phencyclidine and its analogs, barbiturates, and cocaine or its metabolite benzoylecgonine. A commercially available radioimmunoassay was used with modifications to facilitate screening of whole blood. Increasing sample size increased the sensitivity of the assay. Changing reagent concentration (1:1 dilution), incubation time, sample matrix (water, urine, or blood), or fraction counted (precipitate or supernatant) did not affect the utility of the standard curve or the sensitivity of the assay. All positive results for phencyclidine, opiates, cocaine, and related compounds were confirmed by GC/MA. Barbiturate positives were confirmed by UV spectrophotometry.

  19. Identification of serotypes and virulence markers of Escherichia coli isolated from human stool and urine samples in Egypt

    Directory of Open Access Journals (Sweden)

    K M Osman

    2012-01-01

    Full Text Available Purpose: Haemorrhagic colitis and haemolytic-uremic syndrome are associated with Shiga-toxin producing Escherichia coli (STEC. There are others DEC (Diarrhoeagenic E. coli pathotypes responsible for outbreaks and others toxins associated to these. Most clinical signs of disease arise as a consequence of the production of Shiga toxin 1 (Stx1, Stx2 or combinations of these toxins. Other major virulence factors include E. coli haemolysin (hlyA, and intimin, the product of the eaeA gene that is involved in the attaching and effacing adherence phenotype. Materials and Methods: In this study, the PCR assay was used to detect 12 E. coli genes associated with virulence (stx1, stx2, hylA, Flic h7 , stb, F41, K99, sta, F17, LT-I, LT-II and eaeA. Results: A total of 108 E. coli strains were serotyped into 64 typable strains. The investigated strains from the stool, 8/80 (10% strains were O 164:K, while the 56/110 strains isolated from the urine were O126:K71 (44/110, 40% and O 86:K 61 (12/110, 11%. The distribution pattern of the detected virulence genes was observed to be in the following order: F17 (10% from the stool and 44% from the urine, Sta (10% from the stool, hylA (10% from the stool and 44% from the urine, Stb (44% from the urine and stx1 (27% from the urine. The 8 faecal strains encoded a combination of the F17, Sta and hylA genes, while the 56 urine strains encoded a combination of the F17 0+ Stb + hylA (44/110, 40% and Stx1 only (12/60, 20%. Conclusion: This is the first report on the molecular characterization of E. coli diarrhoeagenic strains in Egypt and the first report on the potential role of E. coli in diarrhoea and urinary tract infections in a localized geographic area where the people engage in various occupational activities.

  20. Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks.

    Science.gov (United States)

    Nischkauer, Winfried; Vanhaecke, Frank; Bernacchi, Sébastien; Herwig, Christoph; Limbeck, Andreas

    2014-11-01

    Nebulising liquid samples and using the aerosol thus obtained for further analysis is the standard method in many current analytical techniques, also with inductively coupled plasma (ICP)-based devices. With such a set-up, quantification via external calibration is usually straightforward for samples with aqueous or close-to-aqueous matrix composition. However, there is a variety of more complex samples. Such samples can be found in medical, biological, technological and industrial contexts and can range from body fluids, like blood or urine, to fuel additives or fermentation broths. Specialized nebulizer systems or careful digestion and dilution are required to tackle such demanding sample matrices. One alternative approach is to convert the liquid into a dried solid and to use laser ablation for sample introduction. Up to now, this approach required the application of internal standards or matrix-adjusted calibration due to matrix effects. In this contribution, we show a way to circumvent these matrix effects while using simple external calibration for quantification. The principle of representative sampling that we propose uses radial line-scans across the dried residue. This compensates for centro-symmetric inhomogeneities typically observed in dried spots. The effectiveness of the proposed sampling strategy is exemplified via the determination of phosphorus in biochemical fermentation media. However, the universal viability of the presented measurement protocol is postulated. Detection limits using laser ablation-ICP-optical emission spectrometry were in the order of 40 μg mL - 1 with a reproducibility of 10 % relative standard deviation (n = 4, concentration = 10 times the quantification limit). The reported sensitivity is fit-for-purpose in the biochemical context described here, but could be improved using ICP-mass spectrometry, if future analytical tasks would require it. Trueness of the proposed method was investigated by cross-validation with

  1. Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks

    Science.gov (United States)

    Nischkauer, Winfried; Vanhaecke, Frank; Bernacchi, Sébastien; Herwig, Christoph; Limbeck, Andreas

    2014-11-01

    Nebulising liquid samples and using the aerosol thus obtained for further analysis is the standard method in many current analytical techniques, also with inductively coupled plasma (ICP)-based devices. With such a set-up, quantification via external calibration is usually straightforward for samples with aqueous or close-to-aqueous matrix composition. However, there is a variety of more complex samples. Such samples can be found in medical, biological, technological and industrial contexts and can range from body fluids, like blood or urine, to fuel additives or fermentation broths. Specialized nebulizer systems or careful digestion and dilution are required to tackle such demanding sample matrices. One alternative approach is to convert the liquid into a dried solid and to use laser ablation for sample introduction. Up to now, this approach required the application of internal standards or matrix-adjusted calibration due to matrix effects. In this contribution, we show a way to circumvent these matrix effects while using simple external calibration for quantification. The principle of representative sampling that we propose uses radial line-scans across the dried residue. This compensates for centro-symmetric inhomogeneities typically observed in dried spots. The effectiveness of the proposed sampling strategy is exemplified via the determination of phosphorus in biochemical fermentation media. However, the universal viability of the presented measurement protocol is postulated. Detection limits using laser ablation-ICP-optical emission spectrometry were in the order of 40 μg mL- 1 with a reproducibility of 10 % relative standard deviation (n = 4, concentration = 10 times the quantification limit). The reported sensitivity is fit-for-purpose in the biochemical context described here, but could be improved using ICP-mass spectrometry, if future analytical tasks would require it. Trueness of the proposed method was investigated by cross-validation with

  2. Classification of bacterial samples as negative or positive for a UTI and antibiogram using surface enhanced Raman spectroscopy

    Science.gov (United States)

    Kastanos, Evdokia; Hadjigeorgiou, Katerina; Kyriakides, Alexandros; Pitris, Costas

    2011-03-01

    Urinary tract infection (UTI) diagnosis requires an overnight culture to identify a sample as positive or negative for a UTI. Additional cultures are required to identify the pathogen responsible for the infection and to test its sensitivity to antibiotics. A rise in ineffective treatments, chronic infections, rising health care costs and antibiotic resistance are some of the consequences of this prolonged waiting period of UTI diagnosis. In this work, Surface Enhanced Raman Spectroscopy (SERS) is used for classifying bacterial samples as positive or negative for UTI. SERS spectra of serial dilutions of E.coli bacteria, isolated from a urine culture, were classified as positive (105-108 cells/ml) or negative (103-104 cells/ml) for UTI after mixing samples with gold nanoparticles. A leave-one-out cross validation was performed using the first two principal components resulting in the correct classification of 82% of all samples. Sensitivity of classification was 88% and specificity was 67%. Antibiotic sensitivity testing was also done using SERS spectra of various species of gram negative bacteria collected 4 hours after exposure to antibiotics. Spectral analysis revealed clear separation between the spectra of samples exposed to ciprofloxacin (sensitive) and amoxicillin (resistant). This study can become the basis for identifying urine samples as positive or negative for a UTI and determining their antibiogram without requiring an overnight culture.

  3. Determination of iodine in human milk and urine | Ayodele | Ife ...

    African Journals Online (AJOL)

    Physiological concentrations of iodine were determined in milk and urine. Recovery studies are reported along with results for the analysis of milk and urine samples. Iodine contents ranged from 10 - 110 (mean 52.88 ± 22.60mg/l) and 10 - 90 (mean 27.64 ±16.70) g/l in milk and urine respectively. A significant difference is ...

  4. Comparison of sample preparation methods for reliable plutonium and neptunium urinalysis using automatic extraction chromatography

    DEFF Research Database (Denmark)

    Qiao, Jixin; Xu, Yihong; Hou, Xiaolin

    2014-01-01

    This paper describes improvement and comparison of analytical methods for simultaneous determination of trace-level plutonium and neptunium in urine samples by inductively coupled plasma mass spectrometry (ICP-MS). Four sample pre-concentration techniques, including calcium phosphate, iron......), it endows urinalysis methods with better reliability and repeatability compared with co-precipitation techniques. In view of the applicability of different pre-concentration techniques proposed previously in the literature, the main challenge behind relevant method development is pointed to be the release...

  5. The Cutoff Level for Urine Protein in Urine Immunofixation Electrophoresis.

    Science.gov (United States)

    Ellidag, Hamit Yasar; Curek, Gulten; Eren, Esin; Aydin, Ozgur; Yilmaz, Necat

    2015-01-01

    Immunofixation electrophoresis (IFE) maintains its importance in diagnosing monoclonal gammopathies. In particular, urine IFE detects free light chains (FLC) in urine samples even at low concentrations and offers higher sensitivity compared to serum electrophoresis and serum IFE. The aim of the present study was to determine the place and significance of quantitative urinary protein measurement before IFE in interpreting the results of subsequent IFE and to determine the most appropriate protein concentrations for the appearance of bands. The records of a total of 600 patients, who underwent screening for Bence Jones proteinuria using IFE on 24-hour urine, were retrospectively reviewed. Urine IFE was performed using Helena SAS-I and SAS-I devices. The total protein concentration in the urine was quantitatively determined by the Pyrogallol red method, and the urine albumin level was determined using the immunoturbidimetric method. These analyses were measured on an Olympus/Beckmann AU5800. The evaluation of IFE results revealed that 311 patients had normal results, 108 patients had monoclonal bands, five patients had biclonal bands, 28 had polyclonal bands, and 148 patients had various degrees of proteinuria. ROC curves were created in order to determine the most appropriate urinary protein and albumin levels to observe bands in IFE. Accordingly, urine baseline protein level (mg/dL) showed the highest AUC value (cutoff value: 19.4 mg/dL, sensitivity: 92%, specificity: 98.2%, AUC: 0.972). The present study showed that quantitative protein measurement before IFE eliminated the disadvantages associated with the IFE method and its interpretation.

  6. CMV genotyping using different samples in post renal transplant recipients with CMV disease

    Directory of Open Access Journals (Sweden)

    Ramya Barani

    2017-10-01

    Full Text Available CMV is the most common viral infection which occurs in post renal transplant recipients (PTR. There are four different gB genotypes (gB1 to gB4 which exist in CMV. Studies have reported that mixed infection with different genotypes will cause severe clinical manifestations as well as co-infection with other herpesvirus including Epstein-Barr virus (EBV [1]. CMV can cause compartmentalized disease involving different organs with different genotypes. There are reports in immuno compromised individuals with different genotypes [2, 3]. Institutional ethics committee approval was obtained prior to conduct of the study (IEC-NI/08/DEC/07/46. Whole blood, saliva and urine were collected from PTR. DNA were extracted (Qiagen DNA mini kit and CMV quantitative PCR targeting ppUL83 gene was performed with CMV R-gene™ using an ABI 7900 Fast real time PCR (SDS Version: 2.4. PTR who had high viral load (>1000 copies/ml in any three or two samples were included for CMV genotyping PCR targeting gB region (410-bp [2]. DNA sequencing was performed in ABI 3730 GA platform by Sanger method and sequences were analyzed by reference strains. A total of 24 samples were collected from 9 PTR. Among these four PTR had high viral load in all three samples (whole blood, urine & saliva and those with high viral load (n=5 in 2 samples (Whole blood & urine/saliva were screened for CMV genotyping. Majority of the strains belonged to genotype B1 and only one PTR was infected with genotype B2 in three samples. In PTR with genotype B1, gastro intestinal infection (GI was predominantly found in 78% (n=7 followed by graft dysfunction (GDF in 56% (n=5 of the PTR. PTR who detected with genotype B2 was associated with fever, leukopenia (CMV syndrome, GDF and also found with EBV infection. Co-infection with EBV was observed in 44% (n=4; VZV and HSV type 1 was also observed. Genotypes are associated with the severity of the disease and co-infection with other herpes virus infections. In

  7. Determination of 131I and thorium in urine

    International Nuclear Information System (INIS)

    Tomida, Rute Miwa

    1978-01-01

    Methods for the determination of 131 I and Thorium in urine have been developed taking into account the monitoring needs for people who handle with these radioisotopes. The method for determining 131 I is based in the use of silver chloride to separate iodine by precipitation from the sample; the detection was carried out in a Nal (Tl) well type scintillator connected to a single channel analyser. This method has the following advantages; it is easy and relatively fast as well as selective, showing a separation yield higher than 80%. Thorium in urine was determined by colorimetry after the mineralization of the sample using nitric acid, and sulphuric acid, and then oxygen peroxide. The chromophore reagent used was Thoron (disodium salt of 2-(2-hydroxy-3,6-disulfo-l-naphthylazo) benzenearsonic acid).The absorbance was measured in a spectro colorimeter at a fixed wavelength (530 nm). The method proved to be simple allowing a separation yield of about 80%. The most representative sample for a monitoring program in a 131 I production laboratory has been established. The 131 I concentration in urine of individuals with chronic contamination have also been measured; an interpretation of these results is discussed. (author)

  8. Antibiotics susceptibility patterns of urine bacterial isolates in Zaria ...

    African Journals Online (AJOL)

    Purpose: The prevalence of E. coli, Ps. aeruginosa and Staph aureus isolates from urine of selected residents in Zaria was investigated. This was an attempt to elucidate the antibiotic susceptibility profiles of these bacteria commonly implicated in urinary tact infection. Methods: Urine samples collected from students of ...

  9. Enhanced conformational sampling using enveloping distribution sampling.

    Science.gov (United States)

    Lin, Zhixiong; van Gunsteren, Wilfred F

    2013-10-14

    To lessen the problem of insufficient conformational sampling in biomolecular simulations is still a major challenge in computational biochemistry. In this article, an application of the method of enveloping distribution sampling (EDS) is proposed that addresses this challenge and its sampling efficiency is demonstrated in simulations of a hexa-β-peptide whose conformational equilibrium encompasses two different helical folds, i.e., a right-handed 2.7(10∕12)-helix and a left-handed 3(14)-helix, separated by a high energy barrier. Standard MD simulations of this peptide using the GROMOS 53A6 force field did not reach convergence of the free enthalpy difference between the two helices even after 500 ns of simulation time. The use of soft-core non-bonded interactions in the centre of the peptide did enhance the number of transitions between the helices, but at the same time led to neglect of relevant helical configurations. In the simulations of a two-state EDS reference Hamiltonian that envelops both the physical peptide and the soft-core peptide, sampling of the conformational space of the physical peptide ensures that physically relevant conformations can be visited, and sampling of the conformational space of the soft-core peptide helps to enhance the transitions between the two helices. The EDS simulations sampled many more transitions between the two helices and showed much faster convergence of the relative free enthalpy of the two helices compared with the standard MD simulations with only a slightly larger computational effort to determine optimized EDS parameters. Combined with various methods to smoothen the potential energy surface, the proposed EDS application will be a powerful technique to enhance the sampling efficiency in biomolecular simulations.

  10. Asymptomatic bacteriuria in pregnant women attending Boo-Ali Hospital Tehran Iran: Urine analysis vs. urine culture.

    Science.gov (United States)

    Etminan-Bakhsh, Mina; Tadi, Sima; Darabi, Roksana

    2017-11-01

    Asymptomatic bacteriuria is one of the common problems in pregnancy. Asymptomatic bacteriuria is associated with pyelonephritis, preterm labor and low birth weight infants. The physiological and anatomical changes in pregnancy facilitate urinary tract infection (UTI) during pregnancy. Several tests are available for diagnosis of asymptomatic bacteriuria. The urine culture is a gold standard diagnostic test for asymptomatic bacteriuria but it is expensive and time-consuming. Screening methods may be useful in detecting high-risk pregnant women for asymptomatic bacteriuria. The aim of the present study was to compare urine analysis as a rapid screening test to urine culture in diagnosis of asymptomatic bacteriuria. A total of 123 pregnant women attending the obstetrics clinic of Boo-Ali hospital in Tehran, Iran from March 2013 to September 2014 were included in the present diagnostic cross-sectional study. One hundred twenty three mid-stream urine samples were inoculated into cultures and were processed by dipstick (nitrite test and leucocyte esterase test) and microscopic pus cell count. The sensitivity, specificity, positive predictive value and negative predictive value of nitrite test, leucocyte esterase test and microscopic pus cell count were compared with urine culture in diagnosis of asymptomatic bacteriuria by using SPSS version 19. Of 123 urine samples, significant asymptomatic bacteriuria (≥10 4 cfu/Ml) was detected in 8 (6.5%) subjects. The sensitivity and specificity of nitrite test were 37% and 100% respectively. The sensitivity of pus cell count alone and leucocyte esterase test alone were 100% but the specificity of them were 64% and 65% respectively. We found high negative predictive value by Pus cell count and the leucocyte esterase test (100%) and low positive predictive value by them (16% and 17% respectively). Urine culture is the most useful test for diagnosis of asymptomatic bacteriuria. None of our screening tests had a sensitivity and

  11. Standard methods for sampling and sample preparation for gamma spectroscopy

    International Nuclear Information System (INIS)

    Taskaeva, M.; Taskaev, E.; Nikolov, P.

    1993-01-01

    The strategy for sampling and sample preparation is outlined: necessary number of samples; analysis and treatment of the results received; quantity of the analysed material according to the radionuclide concentrations and analytical methods; the minimal quantity and kind of the data needed for making final conclusions and decisions on the base of the results received. This strategy was tested in gamma spectroscopic analysis of radionuclide contamination of the region of Eleshnitsa Uranium Mines. The water samples was taken and stored according to the ASTM D 3370-82. The general sampling procedures were in conformity with the recommendations of ISO 5667. The radionuclides was concentrated by coprecipitation with iron hydroxide and ion exchange. The sampling of soil samples complied with the rules of ASTM C 998, and their sample preparation - with ASTM C 999. After preparation the samples were sealed hermetically and measured. (author)

  12. Sequential determination of important ecotoxic radionuclides in nuclear waste samples

    International Nuclear Information System (INIS)

    Bilohuscin, J.

    2016-01-01

    In the dissertation thesis we focused on the development and optimization of a sequential determination method for radionuclides 93 Zr, 94 Nb, 99 Tc and 126 Sn, employing extraction chromatography sorbents TEVA (R) Resin and Anion Exchange Resin, supplied by Eichrom Industries. Prior to the attestation of sequential separation of these proposed radionuclides from radioactive waste samples, a unique sequential procedure of 90 Sr, 239 Pu, 241 Am separation from urine matrices was tried, using molecular recognition sorbents of AnaLig (R) series and extraction chromatography sorbent DGA (R) Resin. On these experiments, four various sorbents were continually used for separation, including PreFilter Resin sorbent, which removes interfering organic materials present in raw urine. After the acquisition of positive results of this sequential procedure followed experiments with a 126 Sn separation using TEVA (R) Resin and Anion Exchange Resin sorbents. Radiochemical recoveries obtained from samples of radioactive evaporate concentrates and sludge showed high efficiency of the separation, while values of 126 Sn were under the minimum detectable activities MDA. Activity of 126 Sn was determined after ingrowth of daughter nuclide 126m Sb on HPGe gamma detector, with minimal contamination of gamma interfering radionuclides with decontamination factors (D f ) higher then 1400 for 60 Co and 47000 for 137 Cs. Based on the acquired experiments and results of these separation procedures, a complex method of sequential separation of 93 Zr, 94 Nb, 99 Tc and 126 Sn was proposed, which included optimization steps similar to those used in previous parts of the dissertation work. Application of the sequential separation method for sorbents TEVA (R) Resin and Anion Exchange Resin on real samples of radioactive wastes provided satisfactory results and an economical, time sparing, efficient method. (author)

  13. The Internet of Samples in the Earth Sciences (iSamples)

    Science.gov (United States)

    Carter, M. R.; Lehnert, K. A.

    2015-12-01

    Across most Earth Science disciplines, research depends on the availability of samples collected above, at, and beneath Earth's surface, on the moon and in space, or generated in experiments. Many domains in the Earth Sciences have recently expressed the need for better discovery, access, and sharing of scientific samples and collections (EarthCube End-User Domain workshops, 2012 and 2013, http://earthcube.org/info/about/end-user-workshops), as has the US government (OSTP Memo, March 2014). The Internet of Samples in the Earth Sciences (iSamples) is an initiative funded as a Research Coordination Network (RCN) within the EarthCube program to address this need. iSamples aims to advance the use of innovative cyberinfrastructure to connect physical samples and sample collections across the Earth Sciences with digital data infrastructures to revolutionize their utility for science. iSamples strives to build, grow, and foster a new community of practice, in which domain scientists, curators of sample repositories and collections, computer and information scientists, software developers and technology innovators engage in and collaborate on defining, articulating, and addressing the needs and challenges of physical samples as a critical component of digital data infrastructure. A primary goal of iSamples is to deliver a community-endorsed set of best practices and standards for the registration, description, identification, and citation of physical specimens and define an actionable plan for implementation. iSamples conducted a broad community survey about sample sharing and has created 5 different working groups to address the different challenges of developing the internet of samples - from metadata schemas and unique identifiers to an architecture of a shared cyberinfrastructure for collections, to digitization of existing collections, to education, and ultimately to establishing the physical infrastructure that will ensure preservation and access of the physical

  14. Sample vial inserts: A better approach for sampling heterogeneous slurry samples in the SRS Defense Waste Processing Facility

    International Nuclear Information System (INIS)

    Coleman, C.J.; Goode, S.R.

    1996-01-01

    A convenient and effective new approach for analyzing DWPF samples involves the use of inserts with volumes of 1.5--3 ml placed in the neck of 14 ml sample vials. The inserts have rims that conform to the rim of the vials so that they sit straight and stable in the vial. The DWPF tank sampling system fills the pre-weighed insert rather than the entire vial, so the vial functions only as the insert holder. The shielded cell operator then removes the vial cap and decants the insert containing the sample into a plastic bottle, crucible, etc., for analysis. Inert materials such as Teflon, plastic, and zirconium are used for the insert so it is unnecessary to separate the insert from the sample for most analyses. The key technique advantage of using inserts to take DWPF samples versus filling sample vials is that it provides a convenient and almost foolproof way of obtaining and handling small volumes of slurry samples in a shielded cell without corrupting the sample. Since the insert allows the entire sample to be analyzed, this approach eliminates the errors inherent with subsampling heterogeneous slurries that comprise DWPF samples. Slurry samples can then be analyzed with confidence. Analysis times are dramatically reduced by eliminating the drying and vitrification steps normally used to produce a homogeneous solid sample. Direct dissolution and elemental analysis of slurry samples are achieved in 8 hours or less compared with 40 hours for analysis of vitrified slurry samples. Comparison of samples taken in inserts versus full vials indicate that the insert does not significantly affect sample composition

  15. Short-term emissions of ammonia and carbon dioxide from cattle urine contaminated tropical grassland microcosm.

    Science.gov (United States)

    Majumdar, Deepanjan; Patel, Manoj; Drabar, Reena; Vyas, Manish

    2006-11-01

    The study was designed to understand the emissions of ammonia (NH(3)) and carbon dioxide (CO(2)) from a single cattle urination event on a tropical grassland and underline the significance of the emissions in the context of huge animal population grazing on large pasture areas in some countries. Emissions of ammonia (NH(3)) and carbon dioxide (CO(2)) were monitored for three weeks from a tropical grassland (dominated by Cynodon dactylon Pers.) microcosm contaminated with cow and buffalo urine. The grassland microcosms were treated with urine (50 and 100 ml of each) only once and irrigated with water once every week. Ammonia was sampled by an automatic sampling system comprising of a vacuum pump, three-way stopcocks and rubber tubing and an impinger containing suitable absorbing solution (H(2)SO(4)), connected to the tubing suitably. The sampled gas, after sucked by the vacuum pump and absorbed in H(2)SO(4), was allowed to enter the closed microcosm again maintaining internal pressure of the microcosm. Carbon dioxide was sampled by absorption in an alkali (NaOH) trap inside the microcosm. Both NH(3) and CO(2) emissions were highly variable temporally and there was no continuous increasing or decreasing emission trend with time. Respectively, 45 and 46% of total NH(3)-N were emitted within first 48 h from 50 and 100 ml cow urine application while the corresponding values for buffalo urine were 34 and 32%. Total NH(3)-N emissions, integrated for sampling days (i.e. 1, 2, 3, 4, 6, 15, 18 and 21st) were 11 and 6% in cow and 8 and 5% in buffalo urine, of the total-N added through 50 and 100 ml urine samples. Carbon dioxide emissions were standardized at 25 degrees C by using a suitable formula which were lower than actual emissions at actual soil temperature (> 25 degrees C). Carbon dioxide emission rates were classified on the basis of soil repiratory classification and classes ranged from moderately low soil activity up to unusually high soil activity, the latter

  16. Detection of novel visible-light region absorbance peaks in the urine after alkalization in patients with alkaptonuria.

    Science.gov (United States)

    Tokuhara, Yasunori; Shukuya, Kenichi; Tanaka, Masami; Mouri, Mariko; Ohkawa, Ryunosuke; Fujishiro, Midori; Takahashi, Tomoo; Okubo, Shigeo; Yokota, Hiromitsu; Kurano, Makoto; Ikeda, Hitoshi; Yamaguchi, Seiji; Inagaki, Shinobu; Ishige-Wada, Mika; Usui, Hiromi; Yatomi, Yutaka; Shimosawa, Tatsuo

    2014-01-01

    Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA) in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2) and compared them with those of urine specimens obtained from healthy volunteers (n = 5) and patients with phenylketonuria (n = 3), and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added) as compared with those in weakly alkaline samples (NH4OH-added). In addition, the peaks disappeared following the addition of ascorbic acid to the samples. We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the diagnosis of alkaptonuria.

  17. Detection of novel visible-light region absorbance peaks in the urine after alkalization in patients with alkaptonuria.

    Directory of Open Access Journals (Sweden)

    Yasunori Tokuhara

    Full Text Available BACKGROUND: Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. METHODS: We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2 and compared them with those of urine specimens obtained from healthy volunteers (n = 5 and patients with phenylketonuria (n = 3, and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. RESULTS: Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added as compared with those in weakly alkaline samples (NH4OH-added. In addition, the peaks disappeared following the addition of ascorbic acid to the samples. CONCLUSIONS: We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the

  18. Direct radioimmunoassay for the detection of barbiturates in blood and urine

    International Nuclear Information System (INIS)

    Mason, P.A.; Law, B.; Pocock, K.; Moffat, A.C.

    1982-01-01

    A radioimmunoassay has been developed for the detection of barbiturates in blood and urine without any pre-treatment of the sample. It is based on a radioiodinated derivative of 4-hydroxyphenobarbitone which allows use of relatively simple gamma-counting procedures. The assay can detect therapeutic levels of barbiturates in very small amounts (50 μl) of blood and urine samples. It is cheap, rapid, simple to perform and is broadly specific for the barbiturate class of drugs to the exclusion of related drugs. The assay is, therefore, very well suited to the task of screening large numbers of samples for the presence of barbiturates. (author)

  19. Evaluation of a PCR Assay for Detection of Streptococcus pneumoniae in Respiratory and Nonrespiratory Samples from Adults with Community-Acquired Pneumonia

    Science.gov (United States)

    Murdoch, David R.; Anderson, Trevor P.; Beynon, Kirsten A.; Chua, Alvin; Fleming, Angela M.; Laing, Richard T. R.; Town, G. Ian; Mills, Graham D.; Chambers, Stephen T.; Jennings, Lance C.

    2003-01-01

    Streptococcus pneumoniae is the most common cause of community-acquired pneumonia, but it is undoubtedly underdiagnosed. We used a nested PCR assay (targeting the pneumolysin gene) to detect S. pneumoniae DNA in multiple sample types from 474 adults with community-acquired pneumonia and 183 control patients who did not have pneumonia. Plasma or buffy coat samples were PCR positive in only 6 of the 21 patients with positive blood cultures for S. pneumoniae and in 12 other patients (4 of whom had no other laboratory evidence of S. pneumoniae infection). Buffy coat samples from two control patients (neither having evidence of S. pneumoniae infection), but no control plasma samples, were PCR positive. Although pneumococcal antigen was detected in the urine from 120 of 420 (29%) patients, only 4 of 227 (2%) urine samples tested were PCR positive. Overall, 256 of 318 (81%) patients had PCR-positive sputum samples, including 58 of 59 samples from which S. pneumoniae was cultured. Throat swab samples from 229 of 417 (55%) patients were PCR positive and, in those who produced sputum, 96% also had positive PCR results from sputum. Throat swabs from 73 of 126 (58%) control patients were also PCR positive. We conclude that the pneumolysin PCR assay adds little to existing diagnostic tests for S. pneumoniae and is unable to distinguish colonization from infection when respiratory samples are tested. PMID:12517826

  20. Accuracy of recommended sampling and assay methods for the determination of plasma-free and urinary fractionated metanephrines in the diagnosis of pheochromocytoma and paraganglioma: a systematic review.

    Science.gov (United States)

    Därr, Roland; Kuhn, Matthias; Bode, Christoph; Bornstein, Stefan R; Pacak, Karel; Lenders, Jacques W M; Eisenhofer, Graeme

    2017-06-01

    To determine the accuracy of biochemical tests for the diagnosis of pheochromocytoma and paraganglioma. A search of the PubMed database was conducted for English-language articles published between October 1958 and December 2016 on the biochemical diagnosis of pheochromocytoma and paraganglioma using immunoassay methods or high-performance liquid chromatography with coulometric/electrochemical or tandem mass spectrometric detection for measurement of fractionated metanephrines in 24-h urine collections or plasma-free metanephrines obtained under seated or supine blood sampling conditions. Application of the Standards for Reporting of Diagnostic Studies Accuracy Group criteria yielded 23 suitable articles. Summary receiver operating characteristic analysis revealed sensitivities/specificities of 94/93% and 91/93% for measurement of plasma-free metanephrines and urinary fractionated metanephrines using high-performance liquid chromatography or immunoassay methods, respectively. Partial areas under the curve were 0.947 vs. 0.911. Irrespective of the analytical method, sensitivity was significantly higher for supine compared with seated sampling, 95 vs. 89% (p sampling compared with 24-h urine, 95 vs. 90% (p sampling, seated sampling, and urine. Test accuracy increased linearly from 90 to 93% for 24-h urine at prevalence rates of 0.0-1.0, decreased linearly from 94 to 89% for seated sampling and was constant at 95% for supine conditions. Current tests for the biochemical diagnosis of pheochromocytoma and paraganglioma show excellent diagnostic accuracy. Supine sampling conditions and measurement of plasma-free metanephrines using high-performance liquid chromatography with coulometric/electrochemical or tandem mass spectrometric detection provides the highest accuracy at all prevalence rates.