WorldWideScience

Sample records for sampled intravenous glucose

  1. Blood Glucose, Insulin and Inorganic Phosphorus in Healthy and Ketotic Dairy Cows after Intravenous Infusion of Glucose Solution

    Directory of Open Access Journals (Sweden)

    Radojica Djoković

    2009-01-01

    Full Text Available The aim of the present study was to determine the degree of blood glucose utilization by peripheral tissue on the basis of changes in blood concentrations of glucose, insulin and inorganic phosphorus in healthy (n = 10 and ketotic cows (n = 10 after intravenous infusion of glucose solution. Blood samples were taken in both groups of examined cows at the following time intervals: just before (time 0 and 30, 60, 120, 180 and 240 min after intravenous infusion of a total of 500 ml of 50% of glucose solution. Glucose and insulin blood serum values in both groups of cows increased significantly within 30 and 60 min of the experiment (p p p < 0.05 in the blood value of inorganic phosphorus in ketotic cows compared to the healthy ones. This is linked with the active entry of glucose into the glucolytic pathway of peripheral tissues. It can thus be concluded that there is a higher degree of blood glucose utilization by peripheral tissues in ketotic cows.

  2. Higher Endogenous Glucose Production during OGTT vs Isoglycemic Intravenous Glucose Infusion

    DEFF Research Database (Denmark)

    Lund, Asger; Bagger, Jonatan I; Christensen, Mikkel Bring

    2016-01-01

    CONTEXT: Oral glucose ingestion elicits a larger insulin response and delayed suppression of glucagon compared to isoglycemic intravenous (iv) glucose infusion (IIGI). OBJECTIVE: We studied whether these differences translate into effects on endogenous glucose production (EGP) and glucose disposal......); HbA1c 53.8 ± 11.0 mmol/mol; duration of diabetes 9.2 ± 5.0 years) and 10 matched non-diabetic control subjects (age 56.0±10.7 years; BMI 29.8 ± 2.9 kg/m(2); HbA1c 33.8 ± 5.5 mmol/mol) Interventions: Three experimental days: 75 g-oral glucose tolerance test (OGTT), IIGI and IIGI+glucagon (IIGI...

  3. Validity of the reduced-sample insulin modified frequently-sampled intravenous glucose tolerance test using the nonlinear regression approach.

    Science.gov (United States)

    Sumner, Anne E; Luercio, Marcella F; Frempong, Barbara A; Ricks, Madia; Sen, Sabyasachi; Kushner, Harvey; Tulloch-Reid, Marshall K

    2009-02-01

    The disposition index, the product of the insulin sensitivity index (S(I)) and the acute insulin response to glucose, is linked in African Americans to chromosome 11q. This link was determined with S(I) calculated with the nonlinear regression approach to the minimal model and data from the reduced-sample insulin-modified frequently-sampled intravenous glucose tolerance test (Reduced-Sample-IM-FSIGT). However, the application of the nonlinear regression approach to calculate S(I) using data from the Reduced-Sample-IM-FSIGT has been challenged as being not only inaccurate but also having a high failure rate in insulin-resistant subjects. Our goal was to determine the accuracy and failure rate of the Reduced-Sample-IM-FSIGT using the nonlinear regression approach to the minimal model. With S(I) from the Full-Sample-IM-FSIGT considered the standard and using the nonlinear regression approach to the minimal model, we compared the agreement between S(I) from the Full- and Reduced-Sample-IM-FSIGT protocols. One hundred African Americans (body mass index, 31.3 +/- 7.6 kg/m(2) [mean +/- SD]; range, 19.0-56.9 kg/m(2)) had FSIGTs. Glucose (0.3 g/kg) was given at baseline. Insulin was infused from 20 to 25 minutes (total insulin dose, 0.02 U/kg). For the Full-Sample-IM-FSIGT, S(I) was calculated based on the glucose and insulin samples taken at -1, 1, 2, 3, 4, 5, 6, 7, 8,10, 12, 14, 16, 19, 22, 23, 24, 25, 27, 30, 40, 50, 60, 70, 80, 90, 100, 120, 150, and 180 minutes. For the Reduced-Sample-FSIGT, S(I) was calculated based on the time points that appear in bold. Agreement was determined by Spearman correlation, concordance, and the Bland-Altman method. In addition, for both protocols, the population was divided into tertiles of S(I). Insulin resistance was defined by the lowest tertile of S(I) from the Full-Sample-IM-FSIGT. The distribution of subjects across tertiles was compared by rank order and kappa statistic. We found that the rate of failure of resolution of S(I) by

  4. Dynamics of morphofunctional erythrocyte properties during intravenous glucose injection in patients with coronary heart disease

    Science.gov (United States)

    Malinova, Lidia I.; Simonenko, Georgy V.; Denisova, Tatyana P.; Tuchin, Valery V.

    2007-02-01

    Dynamics of glucose concentration in human organism is an important diagnostic characteristic for it's parameters correlate significantly with the severity of metabolic, vessel and perfusion disorders. 36 patients with stable angina pectoris of II and III functional classes were involved in this study. All of them were men in age range of 45-59 years old. 7 patients hospitalized with acute myocardial infarction (aged from 49 to 59 years old) form the group of compare. Control group (n = 5) was of practically healthy men in comparable age. To all patients intravenous glucose solution (40%) in standard loading dose was injected. Capillary and vein blood samples were withdrawn before, and 5, 60, 120, 180 and 240 minutes after glucose load. At these time points blood pressure and glucose concentration were measured. In prepared blood smears shape, deformability and sizes of erythrocytes, quantity and degree of shear stress resistant erythrocyte aggregates were studied. Received data were approximated by polynomial of high degree to receive concentration function of studied parameters, which first derivative elucidate velocity characteristics of morphofunctional erythrocyte properties during intravenous glucose injection in patients with coronary heart disease and practically healthy persons. Received data show principle differences in dynamics of morphofunctional erythrocyte properties during intravenous glucose injection in patients with coronary heart disease as a possible mechanism of coronary blood flow destabilization.

  5. Plasma Volume Expansion Resulting from Intravenous Glucose Tolerance Test

    Directory of Open Access Journals (Sweden)

    Robert G. Hahn

    2011-01-01

    Full Text Available Objective. To quantify the degree of plasma volume expansion that occurs during an intravenous glucose tolerance test (IVGTT. Methods. Twenty healthy volunteers (mean age, 28 years underwent IVGTTs in which 0.3 g/kg of glucose 30% was injected as a bolus over 1 min. Twelve blood samples were collected over 75 min. The plasma glucose and blood hemoglobin concentrations were used to calculate the volume distribution (Vd and the clearance (CL of both the exogenous glucose and the injected fluid volume. Results. The IVGTT caused a virtually instant plasma volume expansion of 10%. The half-life of the glucose averaged 15 min and the plasma volume expansion 16 min. Correction of the fluid kinetic model for osmotic effects after injection reduced CL for the infused volume by 85%, which illustrates the strength of osmosis in allocating fluid back to the intracellular fluid space. Simulations indicated that plasma volume expansion can be reduced to 60% by increasing the injection time from 1 to 5 min and reducing the glucose load from 0.3 to 0.2 g/kg. Conclusion. A regular IVGTT induced an acute plasma volume expansion that peaked at 10% despite the fact that only 50–80 mL of fluid were administered.

  6. Hepatic glycogen in humans. II. Gluconeogenetic formation after oral and intravenous glucose

    International Nuclear Information System (INIS)

    Radziuk, J.

    1989-01-01

    The amount of glycogen that is formed by gluconeogenetic pathways during glucose loading was quantitated in human subjects. Oral glucose loading was compared with its intravenous administration. Overnight-fasted subjects received a constant infusion or [3- 3 H]glucose and a marker for gluconeogenesis, [U- 14 C]lactate or sodium [ 14 C]bicarbonate [ 14 C]bicarbonate. An unlabeled glucose load was then administered. Postabsorptively, or after glucose infusion was terminated, a third tracer ([6- 3 H]glucose) infusion was initiated along with a three-step glucagon infusion. Without correcting for background stimulation of [ 14 C]glucose production or for dilution of 14 C with citric acid cycle carbon in the oxaloacetate pool, the amount of glycogen mobilized by the glucagon infusion that was produced by gluconeogenesis during oral glucose loading was 2.9 +/- 0.7 g calculated from [U- 14 C]-lactate incorporation and 7.4 +/- 1.3 g calculated using [ 14 C]bicarbonate as a gluconeogenetic marker. During intravenous glucose administration the latter measurement also yielded 7.2 +/- 1.1 g. When the two corrections above are applied, the respective quantities became 5.3 +/- 1.7 g for [U- 14 C]lactate as tracer and 14.7 +/- 4.3 and 13.9 +/- 3.6 g for oral and intravenous glucose with [ 14 C]bicarbonate as tracer (P less than 0.05, vs. [ 14 C]-lactate as tracer). When [2- 14 C]acetate was infused, the same amount of label was incorporated into mobilized glycogen regardless of which route of glucose administration was used. Comparison with previous data also suggests that 14 CO 2 is a potentially useful marker for the gluconeogenetic process in vivo

  7. Effect of adrenal medullectomy on metabolic responses to chronic intermittent hypoxia in the frequently sampled intravenous glucose tolerance test.

    Science.gov (United States)

    Shin, Mi-Kyung; Han, Woobum; Joo, Hoon; Bevans-Fonti, Shannon; Shiota, Masakazu; Stefanovski, Darko; Polotsky, Vsevolod Y

    2017-04-01

    Obstructive sleep apnea is associated with type 2 diabetes. We have previously developed a mouse model of intermittent hypoxia (IH) mimicking oxyhemoglobin desaturations in patients with sleep apnea and have shown that IH increases fasting glucose, hepatic glucose output, and plasma catecholamines. We hypothesize that adrenal medulla modulates glucose responses to IH and that such responses can be prevented by adrenal medullectomy. We performed adrenal medullectomy or sham surgery in lean C57BL/6J mice, which were exposed to IH or intermittent air (control) for 4 wk followed by the frequently sampled intravenous glucose tolerance test (FSIVGTT) in unanesthetized unrestrained animals. IH was administered during the 12-h light phase (9 AM to 9 PM) by decreasing inspired oxygen from 21 to 6.5% 60 cycles/h. Insulin sensitivity (S I ), insulin independent glucose disposal [glucose effectiveness (S G )], and the insulin response to glucose (AIR G ) were determined using the minimal model method. In contrast to our previous data obtained in restrained mice, IH did not affect fasting blood glucose and plasma insulin levels in sham-operated mice. IH significantly decreased S G but did not affect S I and AIR G Adrenal medullectomy decreased fasting blood glucose and plasma insulin levels and increased glycogen synthesis in the liver in hypoxic mice but did not have a significant effect on the FSIVGTT metrics. We conclude that, in the absence of restraints, IH has no effect on glucose metabolism in lean mice with exception of decreased S G , whereas adrenal medullectomy decreases fasting glucose and insulin levels in the IH environment. NEW & NOTEWORTHY To our knowledge, this is the first study examining the role of adrenal catecholamines in glucose metabolism during intermittent hypoxia (IH) in unanesthetized unrestrained C57BL/6J mice. We report that IH did not affect fasting glucose and insulin levels nor insulin sensitivity and insulin secretion during, whereas glucose

  8. Intravenous immunoglobulin to treat hyperbilirubinemia in neonates with isolated Glucose-6-Phosphate dehydrogenase deficiency

    Directory of Open Access Journals (Sweden)

    Wadah Khriesat

    2017-04-01

    Full Text Available Background Glucose-6-phosphate dehydrogenase deficiency alone or concomitant with ABO isoimmunisation is a widespread indication for neonatal exchange transfusion. Aims To evaluate the effectiveness of Intravenous Immunoglobulin in the treatment of neonatal hyperbilirubinemia due to glucose-6-phosphate dehydrogenase deficiency. Methods A retrospective cohort study was conducted between 2006 and 2014 at the Jordan University of Science and technology. The medical records of 43 infants admitted to the neonatal intensive care unit for isolated glucose-6- phosphate dehydrogenase deficiency hemolytic disease of the newborns were reviewed. Patients were divided into two groups. Group I, a historical cohort, included newborns born between 2006 and 2010, Treatment included phototherapy and exchange transfusion. Group II included newborns born between 2011 and 2014, where, in addition to phototherapy, intravenous immunoglobulin was administered. The duration of phototherapy and number of exchange transfusions were evaluated. Results Of 412 newborns that were admitted with neonatal hyperbilirubinemia, Glucose-6-phosphate dehydrogenase deficiency was present in 43. Of these, 22, did not receive intravenous immunoglobulin and served as a control group. The other 21 newborns received intravenous immunoglobulin. There was no difference in the demographic characteristics between the two groups. Infants in the control group were significantly more likely to receive exchange blood transfusion than infants in the immunoglobulin treatment group, but were significantly less likely to need phototherapy. Conclusion Intravenous immunoglobulin is an effective alternative to exchange transfusion in infants with glucose-6-phosphate dehydrogenase deficiency hemolytic disease of the newborn. It is suggested that intravenous immunoglobulin may be beneficial as a prophylaxis for infants with hyperbilirubinemia.

  9. Characterization of the intravenous glucose tolerance test and the combined glucose-insulin test in donkeys.

    Science.gov (United States)

    Mendoza, F J; Aguilera-Aguilera, R; Gonzalez-De Cara, C A; Toribio, R E; Estepa, J C; Perez-Ecija, A

    2015-12-01

    Glucose-insulin dynamic challenges such as the intravenous glucose tolerance test (IVGTT) and combined glucose-insulin test (CGIT) have not been described in donkeys. The objectives of this study were (1) to characterize the IVGTT and CGIT in healthy adult donkeys, and (2) to establish normal glucose-insulin proxies. Sixteen donkeys were used and body morphometric variables obtained each. For the IVGTT, glucose (300 mg/kg) was given IV. For the CGIT, glucose (150 mg/kg) followed by recombinant insulin (0.1 IU/kg) were administered IV. Blood samples for glucose and insulin determinations were collected over 300 min. In the IVGTT the positive phase lasted 160.9 ± 13.3 min, glucose concentration peaked at 323.1 ± 9.2 mg/dL and declined at a rate of 1.28 ± 0.15 mg/dL/min. The glucose area under the curve (AUC) was 21.4 ± 1.9 × 10(3) mg/dL/min and the insulin AUC was 7.2 ± 0.9 × 10(3) µIU/mL/min. The positive phase of the CGIT curve lasted 44 ± 3 min, with a glucose clearance rate of 2.01 ± 0.18 mg/dL/min. The negative phase lasted 255.9 ± 3 min, decreasing glucose concentration at rate of -0.63 ± 0.06 mg/dL/min, and reaching a nadir (33.1 ± 3.6 mg/dL) at 118.3 ± 6.3 min. The glucose and insulin AUC values were 15.2 ± 0.9 × 10(3) mg/dL/min and 13.2 ± 0.9 × 10(3) µIU/mL/min. This is the first study characterizing CGIT and IVGTT, and glucose-insulin proxies in healthy adult donkeys. Distinct glucose dynamics, when compared with horses, support the use of species-specific protocols to assess endocrine function. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Changes in blood glucose and insulin responses to intravenous glucose tolerance tests and blood biochemical values in adult female Japanese black bears (Ursus thibetanus japonicus).

    Science.gov (United States)

    Kamine, Akari; Shimozuru, Michito; Shibata, Haruki; Tsubota, Toshio

    2012-02-01

    The metabolic mechanisms to circannual changes in body mass of bears have yet to be elucidated. We hypothesized that the Japanese black bear (Ursus thibetanus japonicus) has a metabolic mechanism that efficiently converts carbohydrates into body fat by altering insulin sensitivity during the hyperphagic stage before hibernation. To test this hypothesis, we investigated the changes in blood biochemical values and glucose and insulin responses to intravenous glucose tolerance tests (IVGTT) during the active season (August, early and late November). Four, adult, female bears (5-17 years old) were anesthetized with 6 mg/kg TZ (tiletamine HCl and zolazepam HCl) in combination with 0.1 mg/kg acepromazine maleate. The bears were injected intravenously with glucose (0.5 g/kg of body mass), and blood samples were obtained before, at, and intermittently after glucose injection. The basal triglycerides concentration decreased significantly with increase in body mass from August to November. Basal levels of plasma glucose and serum insulin concentrations were not significantly different among groups. The results of IVGTT demonstrated the increased peripheral insulin sensitivity and glucose tolerance in early November. In contrast, peripheral insulin resistance was indicated by the exaggerated insulin response in late November. Our findings suggest that bears shift their glucose and lipid metabolism from the stage of normal activity to the hyperphagic stage in which they show lipogenic-predominant metabolism and accelerate glucose uptake by increasing the peripheral insulin sensitivity.

  11. Blood glucose control in healthy subject and patients receiving intravenous glucose infusion or total parenteral nutrition using glucagon-like peptide 1

    DEFF Research Database (Denmark)

    Nauck, Michael A; Walberg, Jörg; Vethacke, Arndt

    2004-01-01

    It was the aim of the study to examine whether the insulinotropic gut hormone GLP-1 is able to control or even normalise glycaemia in healthy subjects receiving intravenous glucose infusions and in severely ill patients hyperglycaemic during total parenteral nutrition.......It was the aim of the study to examine whether the insulinotropic gut hormone GLP-1 is able to control or even normalise glycaemia in healthy subjects receiving intravenous glucose infusions and in severely ill patients hyperglycaemic during total parenteral nutrition....

  12. Stable-label intravenous glucose tolerance test minimal model

    International Nuclear Information System (INIS)

    Avogaro, A.; Bristow, J.D.; Bier, D.M.; Cobelli, C.; Toffolo, G.

    1989-01-01

    The minimal model approach to estimating insulin sensitivity (Sl) and glucose effectiveness in promoting its own disposition at basal insulin (SG) is a powerful tool that has been underutilized given its potential applications. In part, this has been due to its inability to separate insulin and glucose effects on peripheral uptake from their effects on hepatic glucose inflow. Prior enhancements, with radiotracer labeling of the dosage, permit this separation but are unsuitable for use in pregnancy and childhood. In this study, we labeled the intravenous glucose tolerance test (IVGTT) dosage with [6,6- 2 H 2 ]glucose, [2- 2 H]glucose, or both stable isotopically labeled glucose tracers and modeled glucose kinetics in six postabsorptive, nonobese adults. As previously found with the radiotracer model, the tracer-estimated S*l derived from the stable-label IVGTT was greater than Sl in each case except one, and the tracer-estimated SG* was less than SG in each instance. More importantly, however, the stable-label IVGTT estimated each parameter with an average precision of +/- 5% (range 3-9%) compared to average precisions of +/- 74% (range 7-309%) for SG and +/- 22% (range 3-72%) for Sl. In addition, because of the different metabolic fates of the two deuterated tracers, there were minor differences in basal insulin-derived measures of glucose effectiveness, but these differences were negligible for parameters describing insulin-stimulated processes. In conclusion, the stable-label IVGTT is a simple, highly precise means of assessing insulin sensitivity and glucose effectiveness at basal insulin that can be used to measure these parameters in individuals of all ages, including children and pregnant women

  13. Changes in Blood Values of Glucose, Insulin and Inorganic Phosphorus in Healthy and Ketotic Dairy Cows after Intravenous Infusion of Propionate Solution

    Directory of Open Access Journals (Sweden)

    R. Djoković

    2007-01-01

    Full Text Available The aim of the present study was to determine the degree of blood glucose utilization by peripheral tissue on the basis of changes in blood concentrations of glucose, insulin and inorganic phosphorus in healthy (n = 10 and ketotic cows (n = 10 after intravenous infusion of propionate solution. Blood samples were taken in both groups of examined cows at the following time intervals: just before (time 0 and 8, 30, 60, 120, 180, 240 and 480 min after the intravenous infusion of 1.84 mol l-1 solution of propionate in the amount of 1 ml kg-1 of body weight. Glucose and insulin blood serum values in both groups of cows increased significantly within 120 min of the experiment (p p p p < 0.05 in blood value of inorganic phosphorus in ketotic cows in comparison with healthy ones. This is linked with the active entry of glucose into glucolytic pathway of peripheral tissues. It can thus be concluded that there is a higher degree of blood glucose utilization by peripheral tissues in ketotic cows.

  14. Effect of intravenous glucose infusion on renal function in normal man and in insulin-dependent diabetics

    DEFF Research Database (Denmark)

    Frandsen, M; Parving, H H; Christiansen, JS

    1981-01-01

    The effect of intravenous glucose infusion on glomerular filtration rate and renal plasma flow (constant infusion technique using 125I-iothalamate and 131I-hippuran) and on urinary excretion of albumin and beta-2-microglobulin were studied in ten normal subjects and seven metabolically well......-controlled insulin-dependent diabetics. Following glucose infusion in normal subjects (n = 10) blood glucose increased from 4.7 +/- 0.1 to 10.9 +/- 0.4 mmol/l (SEM) (p less than or equal to 0.01). Glomerular filtration rate increased from 116 +/- 2 to 123 +/- 3 ml/mi x 1.73 m2 (p less than or equal to 0.01), while...... no change in renal plasma flow was seen - 552 +/- 11 versus 553 +/- 18 ml/min x 1.73 m2. Volume expansion with intravenous saline infusion in six of the normal subjects induced no changes in blood glucose or kidney function. In seven strictly controlled insulin-dependent diabetics, blood glucose values were...

  15. Hepatic glycogen in humans. I. Direct formation after oral and intravenous glucose or after a 24-h fast

    International Nuclear Information System (INIS)

    Radziuk, J.

    1989-01-01

    The formation of hepatic glycogen by the direct pathway is assessed in humans after a 12-h fast and oral loading (100 g) or intravenous infusion (90 g) and after a 24-h fast and the same oral glucose load. The methodology used is based on the double tracer method. [3- 3 H]glucose is infused at a constant rate for the determination of the metabolic clearance of glucose. [1- 14 C]glucose is administered with the glucose load. One hour after absorption or the intravenous glucose infusion is terminated, a glucagon infusion is initiated to mobilize the glycogen labeled with [1- 14 C]glucose and formed during the absorptive period. At this time a third tracer, [6- 3 H]glucose, is administered to measure glucose clearance. It was found that after the 12-h fast and oral glucose loading 7.2 +/- 1.1 g of hepatic glycogen appears to be formed directly from glucose compared with 8.4 +/- 1.0 g after the same load and a 24-h fast and 8.5 +/- 0.4 g after a 12-h fast and an equivalent intravenous glucose infusion. When the amount of label ([ 14 C]glucose) mobilized that was not corrected for metabolic recycling was calculated, the data suggested that the amount of glycogen formed by gluconeogenic pathways was probably at least equal to that formed by direct uptake. It was also approximately 60% greater after a 24-h fast. It can be concluded that the amount of hepatic glycogen formed directly from glucose during glucose loading is not significantly altered by the route of entry or the extension of the fasting period to 24 h. The data suggest, however, that gluconeogenetic formation of glycogen increases with fasting

  16. Effects of sitagliptin and metformin treatment on incretin hormone and insulin secretory responses to oral and "isoglycemic" intravenous glucose

    DEFF Research Database (Denmark)

    Vardarli, Irfan; Arndt, Elisabeth; Deacon, Carolyn F

    2014-01-01

    ,000 mg/day), sitagliptin (100 mg/day), or their combination, on GLP-1 responses and on the incretin effect in 20 patients with type 2 diabetes, comparing an oral glucose challenge (75 g, day 5) and an "isoglycemic" intravenous glucose infusion (day 6). Fasting total GLP-1 was significantly increased...... by metformin and not changed by sitagliptin. After oral glucose, metformin increased and sitagliptin significantly decreased (by 53%) total GLP-1. Fasting and postload intact GLP-1 increased with sitagliptin but not with metformin. After oral glucose, only sitagliptin, but not metformin, significantly...... the numerical contribution of the incretin effect. Insulin secretion with sitagliptin treatment was similarly stimulated with oral and "isoglycemic" intravenous glucose. This points to an important contribution of small changes in incretin concentrations within the basal range or to additional insulinotropic...

  17. Central and peripheral contributions to dynamic changes in nucleus accumbens glucose induced by intravenous cocaine

    Directory of Open Access Journals (Sweden)

    Ken Taro Wakabayashi

    2015-02-01

    Full Text Available The pattern of neural, physiological and behavioral effects induced by cocaine is consistent with metabolic neural activation, yet direct attempts to evaluate central metabolic effects of this drug have produced controversial results. Here, we used enzyme-based glucose sensors coupled with high-speed amperometry in freely moving rats to examine how intravenous cocaine at a behaviorally active dose affects extracellular glucose levels in the nucleus accumbens (NAc, a critical structure within the motivation-reinforcement circuit. In drug-naive rats, cocaine induced a bimodal increase in glucose, with the first, ultra-fast phasic rise appearing during the injection (latency 6-8 s; ~50 µM or ~5% of baseline followed by a larger, more prolonged tonic elevation (~100 µM or 10% of baseline, peak ~15 min. While the rapid, phasic component of the glucose response remained stable following subsequent cocaine injections, the tonic component progressively decreased. Cocaine-methiodide, cocaine’s peripherally acting analog, induced an equally rapid and strong initial glucose rise, indicating cocaine’s action on peripheral neural substrates as its cause. However, this analog did not induce increases in either locomotion or tonic glucose, suggesting direct central mediation of these cocaine effects. Under systemic pharmacological blockade of dopamine transmission, both phasic and tonic components of the cocaine-induced glucose response were only slightly reduced, suggesting a significant role of non-dopamine mechanisms in cocaine-induced accumbal glucose influx. Hence, intravenous cocaine induces rapid, strong inflow of glucose into NAc extracellular space by involving both peripheral and central, non-dopamine drug actions, thus preventing a possible deficit resulting from enhanced glucose use by brain cells.

  18. Inorganic phosphorus decrease after intravenous glucose tolerance test is associated with insulin resistance in dairy cows

    OpenAIRE

    Cincović, Marko R.; Djoković, Radojica; Belić, Branislavav; Potkonjak, Aleksandar; Toholj, Bojan; Stojanac, Nenad; Stevančević, Ognjen; Starič, Jože

    2017-01-01

    Inorganic phosphorus (Pi) concentration in blood decreases during an intravenous glucose tolerance test (IVGTT) due to the increase in the level of insulin and glucose. The objective of the present study was to determine the relationship between the intensity of Pi decrease with a dynamic change of insulin and glucose during IVGTT (AUC - total area under curve, AUC increment - area under curve from start of IVGTT to time of maximal response and glucose CR-clearance rate), as well as RQUICKI (...

  19. Response of plasma glucose, insulin, and nonesterified fatty acids to intravenous glucose tolerance tests in dairy cows during a 670-day lactation.

    Science.gov (United States)

    Marett, L C; Auldist, M J; Moate, P J; Wales, W J; Macmillan, K L; Dunshea, F R; Leury, B J

    2015-01-01

    This experiment investigated the metabolic response of dairy cows undergoing an extended lactation to a frequently sampled intravenous glucose tolerance test. The experiment used 12 multiparous Holstein cows that calved in late winter in a seasonally calving pasture-based system and were managed for a 670-d lactation by delaying rebreeding. In each of four 5-wk experimental periods commencing at approximately 73, 217, 422, and 520 (±9.1) days in milk (DIM), cows were offered a diet of perennial ryegrass (73 and 422 DIM) or pasture hay and silage (217 and 520 DIM) supplemented with 1kg of DM grain (control; CON) or 6kg of DM grain (GRN) as a ration. Daily energy intake was approximately 160 and 215 MJ of metabolizable energy/cow for the CON and GRN treatments, respectively. At all other times, cows were managed as a single herd and grazed pasture supplemented with grain to an estimated minimum daily total intake of 180 MJ of metabolizable energy/cow. Cows were fitted with an indwelling jugular catheter during the final week of each experimental period. The standard intravenous glucose tolerance test using 0.3g of glucose per kilogram of body weight was performed on each cow at approximately 100, 250, 460, and 560 DIM. Plasma concentrations of glucose, insulin, and nonesterified fatty acids (NEFA) responses were measured. Milk yield, milk solids yield, body weight, and basal plasma glucose were greater in the GRN compared with the CON treatment. The area under the plasma response curve relative to baseline (AUC) for glucose, insulin, and NEFA and their apparent fractional clearance rates indicated varied whole body responsiveness to insulin in terms of glucose metabolism throughout the 670-d lactation. The glucose AUC 0 to 20 min postinfusion was increased at 560 DIM, indicating reduced utilization of glucose by the mammary gland at this stage of lactation. The NEFA clearance rate, 6 to 30 min postinfusion, was greater at 460 and 560 DIM. These data indicated an

  20. Proglucagon products in plasma of noninsulin-dependent diabetics and nondiabetic controls in the fasting state and after oral glucose and intravenous arginine

    DEFF Research Database (Denmark)

    Orskov, C; Jeppesen, J; Madsbad, S

    1991-01-01

    We investigated the major products of proglucagon (PG) processing in plasma in the fasting state, after intravenous arginine and after an oral glucose load in noninsulin-dependent diabetics (NIDDM) and in weight matched controls using specific radioimmunoassays and analytical gel filtration...... integrated incremental responses after intravenous arginine were identical in the two groups. After oral glucose the insulin concentrations in plasma were lower and the concentrations of all proglucagon products were higher in the NIDDM group compared to the control group. The gel filtration analysis showed....... In the fasting state the glucagonlike peptide-1 (GLP-1) immunoreactivity was significantly elevated in the NIDDM group compared with the control group. Both after intravenous arginine and after an oral glucose load a rise in the plasma concentrations of all immunoreactive moieties measured was seen. All...

  1. Effect of prolonged intravenous glucose and essential amino acid infusion on nitrogen balance, muscle protein degradation and ubiquitin-conjugating enzyme gene expression in calves

    Directory of Open Access Journals (Sweden)

    Scaife Jes R

    2008-02-01

    Full Text Available Abstract Background Intravenous infusions of glucose and amino acids increase both nitrogen balance and muscle accretion. We hypothesised that co-infusion of glucose (to stimulate insulin and essential amino acids (EAA would act additively to improve nitrogen balance by decreasing muscle protein degradation in association with alterations in muscle expression of components of the ubiquitin-proteasome proteolytic pathway. Methods We examined the effect of a 5 day intravenous infusions of saline, glucose, EAA and glucose + EAA, on urinary nitrogen excretion and muscle protein degradation. We carried out the study in 6 restrained calves since ruminants offer the advantage that muscle protein degradation can be assessed by excretion of 3 methyl-histidine and multiple muscle biopsies can be taken from the same animal. On the final day of infusion blood samples were taken for hormone and metabolite measurement and muscle biopsies for expression of ubiquitin, the 14-kDa E2 ubiquitin conjugating enzyme, and proteasome sub-units C2 and C8. Results On day 5 of glucose infusion, plasma glucose, insulin and IGF-1 concentrations were increased while urea nitrogen excretion and myofibrillar protein degradation was decreased. Co-infusion of glucose + EAA prevented the loss of urinary nitrogen observed with EAA infusions alone and enhanced the increase in plasma IGF-1 concentration but there was no synergistic effect of glucose + EAA on the decrease in myofibrillar protein degradation. Muscle mRNA expression of the ubiquitin conjugating enzyme, 14-kDa E2 and proteasome sub-unit C2 were significantly decreased, after glucose but not amino acid infusions, and there was no further response to the combined infusions of glucose + EAA. Conclusion Prolonged glucose infusion decreases myofibrillar protein degradation, prevents the excretion of infused EAA, and acts additively with EAA to increase plasma IGF-1 and improve net nitrogen balance. There was no evidence of

  2. Effects of intravenous glucose infusion and nutritional balance on serum concentrations of nonesterified fatty acids, glucose, insulin, and progesterone in nonlactating dairy cows.

    Science.gov (United States)

    Vieira, F V R; Lopes, C N; Cappellozza, B I; Scarpa, A B; Cooke, R F; Vasconcelos, J L M

    2010-07-01

    The objective of this study was to evaluate serum concentrations of nonesterified fatty acids, glucose, insulin, and progesterone in nonlactating dairy cows according to nutritional balance and glucose infusion. Ten nonlactating, ovariectomized Gir x Holstein cows were stratified by body weight (BW) and body condition score (BCS) on d -28 of the study, and randomly assigned to 1) negative nutrient balance (NB) or 2) positive nutrient balance (PB). From d -28 to d 0, cows were allocated according to nutritional treatment (5 cows/treatment) into 2 low-quality pastures with reduced forage availability. However, PB cows individually received, on average, 3 kg/cow per day (as-fed) of a concentrate during the study. All cows had an intravaginal progesterone releasing device inserted on d -14, which remained in cows until the end of the study. Cow BW and BCS were assessed again on d 0. On d 0, cows within nutritional treatment were randomly assigned to receive, in a crossover design containing 2 periods of 24h each, 1) intravenous glucose infusion (GLU; 0.5 g of glucose/kg of BW, as a 5% glucose solution administered, on average, at 32 mL/min over a 3-h period), or 2) intravenous saline infusion (SAL; 0.9% solution infused on average at 32 mL/min over a 3-h period). Prior to the beginning of each period, all cows were fasted for 12h. Blood samples were collected, relative to the beginning of the infusion, at -12 and -11.5h (beginning of fasting), and at -0.5, 0, 0.5, 1, 2, 3, 4, 5, and 6h. Following the last blood collection of period 1, cows received (PB) or not (NB) concentrate and were returned to their respective pastures. Changes in BCS and BW were greater in NB cows compared with PB cows (-0.60 and -0.25+/-0.090 for BCS, respectively; -22.4 and 1.2+/-6.58 kg for BW, respectively). Cows receiving GLUC had greater glucose concentrations from 0.5 to 3h relative to infusion compared with SAL cows. Insulin concentrations were greater in PB cows assigned to GLUC compared

  3. Glycemic increase induced by intravenous glucose infusion fails to affect hunger, appetite, or satiety following breakfast in healthy men.

    Science.gov (United States)

    Schultes, Bernd; Panknin, Ann-Kristin; Hallschmid, Manfred; Jauch-Chara, Kamila; Wilms, Britta; de Courbière, Felix; Lehnert, Hendrik; Schmid, Sebastian M

    2016-10-01

    Meal-dependent fluctuations of blood glucose and corresponding endocrine signals such as insulin are thought to provide important regulatory input for central nervous processing of hunger and satiety. Since food intake also triggers the release of numerous gastrointestinal signals, the specific contribution of changes in blood glucose to appetite regulation in humans has remained unclear. Here we tested the hypothesis that inducing glycemic fluctuations by intravenous glucose infusion is associated with concurrent changes in hunger, appetite, and satiety. In a single blind, counter-balanced crossover study 15 healthy young men participated in two experimental conditions on two separate days. 500 ml of a solution containing 50 g glucose or 0.9% saline, respectively, was intravenously infused over a 1-h period followed by a 1-h observation period. One hour before start of the respective infusion subjects had a light breakfast (284 kcal). Blood glucose and serum insulin concentrations as well as self-rated feelings of hunger, appetite, satiety, and fullness were assessed during the entire experiment. Glucose as compared to saline infusion markedly increased glucose and insulin concentrations (peak glucose level: 9.7 ± 0.8 vs. 5.3 ± 0.3 mmol/l; t(14) = -5.159, p hunger, appetite satiety, and fullness did not differ from the control condition throughout the experiment. These findings clearly speak against the notion that fluctuations in glycemia and also insulinemia represent major signals in the short-term regulation of hunger and satiety. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. B-type natriuretic peptide (BNP) affects the initial response to intravenous glucose: a randomised placebo-controlled cross-over study in healthy men.

    Science.gov (United States)

    Heinisch, B B; Vila, G; Resl, M; Riedl, M; Dieplinger, B; Mueller, T; Luger, A; Pacini, G; Clodi, M

    2012-05-01

    B-type natriuretic peptide (BNP) is a hormone released from cardiomyocytes in response to cell stretching and elevated in heart failure. Recent observations indicate a distinct connection between chronic heart failure and diabetes mellitus. This study investigated the role of BNP on glucose metabolism. Ten healthy volunteers (25 ± 1 years; BMI 23 ± 1 kg/m(2); fasting glucose 4.6 ± 0.1 mmol/l) were recruited to a participant-blinded investigator-open placebo-controlled cross-over study, performed at a university medical centre. They were randomly assigned (sequentially numbered opaque sealed envelopes) to receive either placebo or 3 pmol kg(-1) min(-1) BNP-32 intravenously during 4 h on study day 1 or 2. One hour after beginning the BNP/placebo infusion, a 3 h intravenous glucose tolerance test (0.33 g/kg glucose + 0.03 U/kg insulin at 20 min) was performed. Plasma glucose, insulin and C-peptide were frequently measured. Ten volunteers per group were analysed. BNP increased the initial glucose distribution volume (13 ± 1% body weight vs 11 ± 1%, p < 0.002), leading to an overall reduction in glucose concentration (p < 0.001), particularly during the initial 20 min of the test (p = 0.001), accompanied by a reduction in the initial C-peptide levels (1.42 ± 0.13 vs 1.62 ± 0.10 nmol/l, p = 0.015). BNP had no impact on beta cell function, insulin clearance or insulin sensitivity and induced no adverse effects. Intravenous administration of BNP increases glucose initial distribution volume and lowers plasma glucose concentrations following a glucose load, without affecting beta cell function or insulin sensitivity. These data support the theory that BNP has no diabetogenic properties, but improves metabolic status in men, and suggest new questions regarding BNP-induced differences in glucose availability and signalling in various organs/tissues. ClinicalTrials.gov: NCT01324739 The study was funded by Jubilée Fonds of the Austrian National Bank (OeNB-Fonds).

  5. Intravenous glucagon-like peptide 1 normalizes blood glucose after major surgery in patients with type 2 diabetes

    DEFF Research Database (Denmark)

    Meier, Juris J; Weyhe, Dirk; Michaely, Mark

    2004-01-01

    of GLP-1 (1.2 pmol x kg x min) and placebo over 8 hrs, each administered in randomized order in the fasting state. C-reactive protein concentrations of 4.9+/-4.2 mg/dL indicated a systemic inflammation. Blood was drawn in 30-min intervals for glucose (glucose oxidase), insulin, C-peptide, glucagon...... practicability and the risk of hypoglycemia. Therefore, the glucose-lowering effect of the incretin hormone glucagon-like peptide 1 (GLP-1) was investigated in patients with type 2 diabetes after major surgery. DESIGN: Randomised clinical study. SETTING: A surgical unit of a university hospital. PATIENTS......, and GLP-1 (specific immunoassays). Statistics were done with repeated-measures analysis of variance and Duncan's post hoc tests. MAIN RESULTS: During the intravenous infusion of GLP-1, plasma glucose concentrations were significantly lowered, reaching the normoglycemic fasting glucose range within 150...

  6. Accuracy of Capillary and Arterial Whole Blood Glucose Measurements Using a Glucose Meter in Patients under General Anesthesia in the Operating Room.

    Science.gov (United States)

    Karon, Brad S; Donato, Leslie J; Larsen, Chelsie M; Siebenaler, Lindsay K; Wells, Amy E; Wood-Wentz, Christina M; Shirk-Marienau, Mary E; Curry, Timothy B

    2017-09-01

    The aim of this study was to evaluate the use of a glucose meter with surgical patients under general anesthesia in the operating room. Glucose measurements were performed intraoperatively on 368 paired capillary and arterial whole blood samples using a Nova StatStrip (Nova Biomedical, USA) glucose meter and compared with 368 reference arterial whole blood glucose measurements by blood gas analyzer in 196 patients. Primary outcomes were median bias (meter minus reference), percentage of glucose meter samples meeting accuracy criteria for subcutaneous insulin dosing as defined by Parkes error grid analysis for type 1 diabetes mellitus, and accuracy criteria for intravenous insulin infusion as defined by Clinical and Laboratory Standards Institute guidelines. Time under anesthesia, patient position, diabetes status, and other variables were studied to determine whether any affected glucose meter bias. Median bias (interquartile range) was -4 mg/dl (-9 to 0 mg/dl), which did not differ from median arterial meter bias of -5 mg/dl (-9 to -1 mg/dl; P = 0.32). All of the capillary and arterial glucose meter values met acceptability criteria for subcutaneous insulin dosing, whereas only 89% (327 of 368) of capillary and 93% (344 of 368) arterial glucose meter values met accuracy criteria for intravenous insulin infusion. Time, patient position, and diabetes status were not associated with meter bias. Capillary and arterial blood glucose measured using the glucose meter are acceptable for intraoperative subcutaneous insulin dosing. Whole blood glucose on the meter did not meet accuracy guidelines established specifically for more intensive (e.g., intravenous insulin) glycemic control in the acute care environment.

  7. Effects of intravenous glucose on dopaminergic function in the human brain in vivo.

    Science.gov (United States)

    Haltia, Lauri T; Rinne, Juha O; Merisaari, Harri; Maguire, Ralph P; Savontaus, Eriika; Helin, Semi; Någren, Kjell; Kaasinen, Valtteri

    2007-09-01

    Dopamine is known to regulate food intake by modulating food reward via the mesolimbic circuitry of the brain. The objective of this study was to compare the effects of high energy input (i.v. glucose) on striatal and thalamic dopamine release in overweight and lean individuals. We hypothesized that glucose would induce dopamine release and positive ratings (e.g., satiety) in Behavioral Analog Scales, particularly in food-deprived lean subjects. [(11)C]raclopride PET was performed for 12 lean (mean BMI = 22 kg/m(2)) and 12 overweight (mean BMI = 33 kg/m(2)) healthy subjects. Each subject was imaged twice in a blinded counter-balanced setting, after 300 mg/kg i.v. glucose and after i.v. placebo. Dopamine D2 receptor binding potentials (BPs) were estimated. The voxel-based analysis of the baseline scans indicated lower striatal BPs in the overweight group and a negative correlation between BMIs and BPs. Intravenous glucose did not have a significant effect on BPs in overweight or lean subjects (male and female groups combined). However, BP changes were opposite in the two gender groups. In male subjects, significant BP reductions after glucose were seen in the right and left caudate nucleus, left putamen, and right thalamus. In female subjects, increases in BP secondary to glucose were seen in the right caudate nucleus and right and left putamen. The sexually dimorphic effect of glucose was seen in both overweight and lean subjects. Although gender differences were not among the a priori hypotheses of the present study and, therefore, they must be considered to be preliminary findings, we postulate that this observation is a reflection of an interaction between glucose, sex steroids (estrogen), leptin, and dopamine.

  8. Oscillatory dynamics of an intravenous glucose tolerance test model with delay interval

    Science.gov (United States)

    Shi, Xiangyun; Kuang, Yang; Makroglou, Athena; Mokshagundam, Sriprakash; Li, Jiaxu

    2017-11-01

    Type 2 diabetes mellitus (T2DM) has become prevalent pandemic disease in view of the modern life style. Both diabetic population and health expenses grow rapidly according to American Diabetes Association. Detecting the potential onset of T2DM is an essential focal point in the research of diabetes mellitus. The intravenous glucose tolerance test (IVGTT) is an effective protocol to determine the insulin sensitivity, glucose effectiveness, and pancreatic β-cell functionality, through the analysis and parameter estimation of a proper differential equation model. Delay differential equations have been used to study the complex physiological phenomena including the glucose and insulin regulations. In this paper, we propose a novel approach to model the time delay in IVGTT modeling. This novel approach uses two parameters to simulate not only both discrete time delay and distributed time delay in the past interval, but also the time delay distributed in a past sub-interval. Normally, larger time delay, either a discrete or a distributed delay, will destabilize the system. However, we find that time delay over a sub-interval might not. We present analytically some basic model properties, which are desirable biologically and mathematically. We show that this relatively simple model provides good fit to fluctuating patient data sets and reveals some intriguing dynamics. Moreover, our numerical simulation results indicate that our model may remove the defect in well known Minimal Model, which often overestimates the glucose effectiveness index.

  9. Comparison of surrogate indices for insulin sensitivity with parameters of the intravenous glucose tolerance test in early lactation dairy cattle.

    Science.gov (United States)

    Alves-Nores, V; Castillo, C; Hernandez, J; Abuelo, A

    2017-10-01

    The aim of this study was to investigate the correlation between different surrogate indices and parameters of the intravenous glucose tolerance test (IVGTT) in dairy cows at the start of their lactation. Ten dairy cows underwent IVGTT on Days 3 to 7 after calving. Areas under the curve during the 90 min after infusion, peak and nadir concentrations, elimination rates, and times to reach half-maximal and basal concentrations for glucose, insulin, nonesterified fatty acids, and β-hydroxybutyrate were calculated. Surrogate indices were computed using the average of the IVGTT basal samples, and their correlation with the IVGTT parameters studied through the Spearman's rank test. No statistically significant or strong correlation coefficients (P > 0.05; |ρ| insulin sensitivity measures derived from the IVGTT and any of the surrogate indices. Therefore, these results support that the assessment of insulin sensitivity in early lactation cattle cannot rely on the calculation of surrogate indices in just a blood sample, and the more laborious tests (ie, hyperinsulinemic euglycemic clamp test or IVGTT) should be employed to predict the sensitivity of the peripheral tissues to insulin accurately. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Exogenous glucagon-like peptide-1 attenuates glucose absorption and reduces blood glucose concentration after small intestinal glucose delivery in critical illness.

    Science.gov (United States)

    Miller, Asaf; Deane, Adam M; Plummer, Mark P; Cousins, Caroline E; Chapple, Lee-Anne S; Horowitz, Michael; Chapman, Marianne J

    2017-03-01

    To evaluate the effect of exogenous glucagonlike peptide-1 (GLP-1) on small intestinal glucose absorption and blood glucose concentrations during critical illness. A prospective, blinded, placebo-controlled, cross-over, randomised trial in a mixed medical-surgical adult intensive care unit, with 12 mechanically ventilated critically ill patients, who were suitable for receiving small intestinal nutrient. On consecutive days, in a randomised order, participants received intravenous GLP-1 (1.2 pmol/ kg/min) or placebo (0.9% saline) as a continuous infusion over 270 minutes. After 6 hours of fasting, intravenous infusions of GLP-1 or placebo began at T = -30 min (in which T = time), with the infusion maintained at a constant rate until study completion at T = 240 min. At T = 0 min, a 100 mL bolus of mixed liquid nutrient meal (1 kcal/mL) containing 3 g of 3-O-methyl-D-gluco-pyranose (3-OMG), a marker of glucose absorption, was administered directly into the small intestine, via a post-pyloric catheter, over 6 minutes. Blood samples were taken at regular intervals for the measurement of plasma glucose and 3-OMG concentrations. Intravenous GLP-1 attenuated initial small intestinal glucose absorption (mean area under the curve [AUC] 0-30 for 3-OMG: GLP-1 group, 4.4 mmol/L/min [SEM, 0.9 mmol/L/min] v placebo group, 6.5 mmol/L/min [SEM, 1.0 mmol/L/min]; P = 0.01), overall small intestinal glucose absorption (mean AUC 0-240 for 3-OMG: GLP-1, 68.2 mmol/L/ min [SEM, 4.7 mmol/L/min] v placebo, 77.7 mmol/L/min [SEM, 4.4 mmol/lLmin]; P = 0.02), small intestinal glucose absorption and overall blood glucose concentration (mean AUC 0-240 for blood glucose: GLP-1, 2062 mmol/L/min [SEM, 111 mmol/L/min] v placebo 2328 mmol/L/min [SEM, 145 mmol/L/min]; P = 0.005). Short-term administration of exogenous GLP-1 reduces small intestinal glucose absorption for up to 4 hours during critical illness. This is likely to be an additional mechanism for the glucose-lowering effect of this agent.

  11. Changes in serum metabolic hormone levels after glucose infusion during lactation cycles in Holstein cows

    Directory of Open Access Journals (Sweden)

    Aliasghar Chalmeh

    2015-02-01

    Full Text Available Negative energy balance can impair the metabolism of high producing dairy cows and supplying the glucose, as an energy source; can prevent the metabolic disorders in these animals. Hence, we hypothesized that bolus intravenous glucose administration may change the concentrations of metabolic hormones in order to prevent and control of metabolic dysfunctions of dairy cows. Twenty five multiparous Holstein dairy cows were divided to 5 equal groups containing early, mid and late lactations, far-off and close-up dry periods. All cows were received dextrose 50% intravenously at 500 mg/kg, 10 mL/kg/h. Blood samples were collected from all animals prior to and 1, 2, 3 and 4 after dextrose 50% infusion and sera were separated to determine glucose, triiodothyronine (T3, thyroxine (T4, serum free T3 (fT3, free T4 (fT4, cortisol and insulin like growth factor-1 (IGF-1. The decreasing pattern of T3 concentration was detected in all studied animals following intravenous glucose infusion (P<0.05. The significant increasing pattern of T4 levels was seen in early and mid lactation cows after glucose administration (P<0.05. The significant decreasing pattern of IGF-1 was detected in mid and late lactations and far-off dry groups (P<0.05. There were no significant alterations in fT3, fT4 and cortisol concentrations following glucose infusion in all experimental groups. In conclusion, bolus intravenous glucose infusion could influence the metabolic hormones in high producing Holstein dairy cows. Alterations of metabolic hormones following bolus intravenous glucose administration indicated that glucose is an important direct controller of metabolic interactions and responses in dairy cows during different physiological states.

  12. EFFECTS OF GLUCOSE-INFUSION ON HORMONE-SECRETION AND HEPATIC GLUCOSE-PRODUCTION DURING HEAVY EXERCISE

    NARCIS (Netherlands)

    WIERSMA, MML; VISSING, J; STEFFENS, AB; GALBO, H

    1993-01-01

    Blood-borne metabolic feedback vs. neural feedforward regulation of glucose homeostasis during exercise was investigated by infusing glucose and [H-3]glucose for glucose appearance determination intravenously in rats running for 20 min at 28 m/min [almost-equal-to 85% of maximal 02 consumption

  13. Incretin Effect and Glucagon Responses to Oral and Intravenous Glucose in Patients with Maturity Onset Diabetes of the Young - Type 2 and Type 3

    DEFF Research Database (Denmark)

    Ostoft, Signe H; Bagger, Jonatan I; Hansen, Torben

    2014-01-01

    Maturity onset diabetes of the young (MODY) is a clinically and genetically heterogeneous subgroup of non-autoimmune diabetes, constituting 1-2% of all diabetes. Because little is known about incretin function in patients with MODY, we studied the incretin effect and hormone responses to oral...... and intravenous glucose loads in patients with glucokinase (GCK)-diabetes (MODY2) and hepatocyte nuclear factor 1α (HNF1A)-diabetes (MODY3), respectively, and in matched healthy control individuals (CTRLs). Both MODY groups exhibited glucose intolerance after oral glucose (most pronounced in patients with HNF1A-diabetes...... incretin effect and inappropriate glucagon responses, whereas incretin effect and glucagon response to oral glucose remain unaffected in GCK-diabetes, reflecting important pathogenetic differences between the two MODY forms....

  14. Rapid fluctuations in extracellular brain glucose levels induced by natural arousing stimuli and intravenous cocaine: fueling the brain during neural activation

    Science.gov (United States)

    Lenoir, Magalie

    2012-01-01

    Glucose, a primary energetic substrate for neural activity, is continuously influenced by two opposing forces that tend to either decrease its extracellular levels due to enhanced utilization in neural cells or increase its levels due to entry from peripheral circulation via enhanced cerebral blood flow. How this balance is maintained under physiological conditions and changed during neural activation remains unclear. To clarify this issue, enzyme-based glucose sensors coupled with high-speed amperometry were used in freely moving rats to evaluate fluctuations in extracellular glucose levels induced by brief audio stimulus, tail pinch (TP), social interaction with another rat (SI), and intravenous cocaine (1 mg/kg). Measurements were performed in nucleus accumbens (NAcc) and substantia nigra pars reticulata (SNr), which drastically differ in neuronal activity. In NAcc, where most cells are powerfully excited after salient stimulation, glucose levels rapidly (latency 2–6 s) increased (30–70 μM or 6–14% over baseline) by all stimuli; the increase differed in magnitude and duration for each stimulus. In SNr, where most cells are transiently inhibited by salient stimuli, TP, SI, and cocaine induced a biphasic glucose response, with the initial decrease (−20–40 μM or 5–10% below baseline) followed by a reboundlike increase. The critical role of neuronal activity in mediating the initial glucose response was confirmed by monitoring glucose currents after local microinjections of glutamate (GLU) or procaine (PRO). While intra-NAcc injection of GLU transiently increased glucose levels in this structure, intra-SNr PRO injection resulted in rapid, transient decreases in SNr glucose. Therefore, extracellular glucose levels in the brain change very rapidly after physiological and pharmacological stimulation, the response is structure specific, and the pattern of neuronal activity appears to be a critical factor determining direction and magnitude of physiological

  15. MATLAB-implemented estimation procedure for model-based assessment of hepatic insulin degradation from standard intravenous glucose tolerance test data.

    Science.gov (United States)

    Di Nardo, Francesco; Mengoni, Michele; Morettini, Micaela

    2013-05-01

    Present study provides a novel MATLAB-based parameter estimation procedure for individual assessment of hepatic insulin degradation (HID) process from standard frequently-sampled intravenous glucose tolerance test (FSIGTT) data. Direct access to the source code, offered by MATLAB, enabled us to design an optimization procedure based on the alternating use of Gauss-Newton's and Levenberg-Marquardt's algorithms, which assures the full convergence of the process and the containment of computational time. Reliability was tested by direct comparison with the application, in eighteen non-diabetic subjects, of well-known kinetic analysis software package SAAM II, and by application on different data. Agreement between MATLAB and SAAM II was warranted by intraclass correlation coefficients ≥0.73; no significant differences between corresponding mean parameter estimates and prediction of HID rate; and consistent residual analysis. Moreover, MATLAB optimization procedure resulted in a significant 51% reduction of CV% for the worst-estimated parameter by SAAM II and in maintaining all model-parameter CV% MATLAB-based procedure was suggested as a suitable tool for the individual assessment of HID process. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  16. Enzymatic assays for detecting lactose and sucrose in urine to reveal intravenous drug abuse with emphasis on buprenorphine.

    Science.gov (United States)

    Keltanen, T; Mariottini, C; Walta, A M; Rahikainen, A L; Ojanperä, I

    2017-06-01

    Buprenorphine and methadone are commonly used medications for opioid maintenance treatment (OMT), using sublingual and oral administration, respectively. Although beneficial for OMT, these drugs can also be abused by intravenous administration. In intravenous abuse cases, the adjuvants lactose and sucrose are excreted in urine without hydrolysis to monosaccharides, since there are no disaccharidases in the blood. We validated enzymatic methods for the analysis of lactose and sucrose in urine. The analytical performance of both assays was considered appropriate for detecting intravenous drug abuse. The principle was proven by analyzing 93 postmortem (PM) urine samples for lactose, following comprehensive toxicological drug screening. In addition, 32 clinical urine samples from potential drug abusers were analyzed to assess the effect of PM changes on the assay. The mean level of lactose was low in clinical samples and relatively low in PM samples in which no drugs were found. Markedly elevated levels were seen in many of the buprenorphine positive samples, suggesting intravenous administration. Enzymatic methods could provide a simple and cost effective way to assess the intravenous administration of OMT drugs or drugs of abuse. Very high levels of glucose in urine may interfere with the assays. Furthermore, other causes for elevated urine disaccharides, such as hypolactasia and increased intestinal permeability, need to be considered in the interpretation of the results. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  17. Pediatric blood sample collection from a pre-existing peripheral intravenous (PIV) catheter.

    Science.gov (United States)

    Braniff, Heather; DeCarlo, Ann; Haskamp, Amy Corey; Broome, Marion E

    2014-01-01

    Aiming to minimize pain in a hospitalized child, the purpose of this observational study was to describe characteristics of blood samples collected from pre-existing peripheral intravenous (PIV) catheters in pediatric patients. One hundred and fifty blood samples were reviewed for number of unusable samples requiring a specimen to be re-drawn. Success of the blood draw and prevalence of the loss of the PIV following blood collection was also measured. Findings included one clotted specimen, success rate of 91.3%, and 1.3% of PIVs becoming non-functional after collection. Obtaining blood specimens from a pre-existing PIV should be considered in a pediatric patient. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Superior Glycemic Control with a Glucose-Responsive Insulin Analog: Hepatic and Nonhepatic Impacts.

    Science.gov (United States)

    Moore, Mary Courtney; Kelley, David E; Camacho, Raul C; Zafian, Peter; Ye, Tian; Lin, Songnian; Kaarsholm, Niels C; Nargund, Ravi; Kelly, Terri M; Van Heek, Margaret; Previs, Stephen F; Moyes, Christopher; Smith, Marta S; Farmer, Ben; Williams, Phil; Cherrington, Alan D

    2018-03-14

    We evaluated the hepatic and nonhepatic responses to glucose-responsive insulin (GRI). Eight dogs received GRI or regular human insulin (HI) in random order. A primed, continuous intravenous infusion of [3- 3 H]glucose began at -120 min. Basal sampling (-30 to 0 min) was followed by 2 study periods (150 min each), P1 and P2. At 0 min, somatostatin and GRI (36±3 pmol/kg/min) or HI (1.8 pmol/kg/min) were infused IV; basal glucagon was replaced intraportally. Glucose was infused intravenously to clamp plasma glucose at 80 mg/dL (P1) and 240 mg/dL (P2). Whole body insulin clearance (WBIC) and insulin concentrations were not different in P1 vs P2 with HI, but WBIC was 23% higher and arterial insulin 16% lower in P1 vs P2 with GRI. Net hepatic glucose output was similar between treatments in P1. In P2, both treatments induced net hepatic glucose uptake (2.1±0.5 [HI] vs 3.3±0.4 [GRI] mg/kg/min). Nonhepatic glucose uptake (nonHGU, mg/kg/min) in P1 and P2, respectively, differed between treatments (2.6±0.3 and 7.4±0.6 with HI; 2.0±0.2 and 8.1±0.8 with GRI). Thus, glycemia impacted GRI but not HI clearance, with resultant differential effects on HGU and nonHGU. GRI holds promise for decreasing hypoglycemia risk while enhancing glucose uptake under hyperglycemic conditions. © 2018 by the American Diabetes Association.

  19. Paper membrane-based SERS platform for the determination of glucose in blood samples.

    Science.gov (United States)

    Torul, Hilal; Çiftçi, Hakan; Çetin, Demet; Suludere, Zekiye; Boyacı, Ismail Hakkı; Tamer, Uğur

    2015-11-01

    In this report, we present a paper membrane-based surface-enhanced Raman scattering (SERS) platform for the determination of blood glucose level using a nitrocellulose membrane as substrate paper, and the microfluidic channel was simply constructed by wax-printing method. The rod-shaped gold nanorod particles were modified with 4-mercaptophenylboronic acid (4-MBA) and 1-decanethiol (1-DT) molecules and used as embedded SERS probe for paper-based microfluidics. The SERS measurement area was simply constructed by dropping gold nanoparticles on nitrocellulose membrane, and the blood sample was dropped on the membrane hydrophilic channel. While the blood cells and proteins were held on nitrocellulose membrane, glucose molecules were moved through the channel toward the SERS measurement area. Scanning electron microscopy (SEM) was used to confirm the effective separation of blood matrix, and total analysis is completed in 5 min. In SERS measurements, the intensity of the band at 1070 cm(-1) which is attributed to B-OH vibration decreased depending on the rise in glucose concentration in the blood sample. The glucose concentration was found to be 5.43 ± 0.51 mM in the reference blood sample by using a calibration equation, and the certified value for glucose was 6.17 ± 0.11 mM. The recovery of the glucose in the reference blood sample was about 88 %. According to these results, the developed paper-based microfluidic SERS platform has been found to be suitable for use for the detection of glucose in blood samples without any pretreatment procedure. We believe that paper-based microfluidic systems may provide a wide field of usage for paper-based applications.

  20. Application of chronic intravascular blood glucose sensor in dogs.

    Science.gov (United States)

    Armour, J C; Lucisano, J Y; McKean, B D; Gough, D A

    1990-12-01

    An intravenous glucose sensor was implanted in six dogs for 1-15 wk. The glucose sensor is a flexible cylinder, approximately 0.2 cm diam and 30 cm long, with a tip containing immobilized glucose oxidase and catalase coupled to a potentiostatic O2 sensor. The sensor and a similar O2 reference sensor were implanted in the superior vena cava near the entrance of the right atrium. The sensor response was conveyed externally either by a telemetry system implanted nearby, surgically accessed leads, or chronically maintained percutaneous leads. Summing over the six implants, there was a total implantation period of 333 days during which glucose sensors were functional on demand. The sensor response showed agreement with conventionally assayed blood samples after accounting for a response lag. Sensor response to glucose showed little change over the implant period. Biocompatibility, enzyme lifetime, O2 availability, O2 sensor stability, and biochemical interference were not limitations. Results demonstrated that this sensor can function effectively as an implant in dogs for a period of months and has the potential for long-term operation.

  1. Glucose-dependent insulinotropic polypeptide

    DEFF Research Database (Denmark)

    Christensen, Mikkel Bring

    2016-01-01

    was to investigate how the blood glucose level affects the glucagon and insulin responses to GIP in healthy subjects (Study 1) and patients with Type 2 diabetes (Study 2), and more specifically to investigate the effects of GIP and GLP-1 at low blood glucose in patients with Type 1 diabetes without endogenous...... as his own control. Interventions were intravenous administration of hormones GIP, GLP-1 and placebo (saline) during different blood glucose levels maintained (clamped) at a certain level. The end-points were plasma concentrations of glucagon and insulin as well as the amount of glucose used to clamp...... the blood glucose levels. In Study 3, we also used stable glucose isotopes to estimate the endogenous glucose production and assessed symptoms and cognitive function during hypoglycaemia. The results from the three studies indicate that GIP has effects on insulin and glucagon responses highly dependent upon...

  2. [Influence of an infusion of 5- or 20% glucose solution on blood glucose and inorganic phosphate concentrations in dairy cows].

    Science.gov (United States)

    Aldaek, T A A; Failing, K; Wehrend, A; Klymiuk, M C

    2011-01-01

    The study was performed to evaluate the influence of an intravenous infusion of 5% and 20% dextrose solution on the plasma concentration of glucose and inorganic phosphate in healthy, dairy cows. Ten healthy, lactating, nonpregnant 3 to 6 year-old Holstein-Friesian cows were included in this investigation. The daily milk yield was 20.3±2.7 liters. Blood plasma concentrations of inorganic phosphate and glucose were determined before, during, immediately and 60 minutes after infusion of 0.9% physiological saline, 5% or 20% dextrose solution. A statistically significant influence of dextrose infusion on blood glucose concentration was observed. After 20% dextrose infusion (200 g dextrose) the blood glucose concentration increased by approximately 13.26 mmol/l. The administration of 5% dextrose solution (50 g dextrose) yielded an increase of blood glucose concentration by 3.31 mmol/l. There was no significant correlation between plasma inorganic phosphate concentrations and infusion of 0.9% saline, 5% or 20% dextrose solution. Intravenous administration of 1000 ml of 5% or 20% dextrose solution does not induce a lasting plasma phosphate reduction and is suitable for elevating the blood glucose concentration.

  3. Pulsatile hyperglucagonemia fails to increase hepatic glucose production in normal man

    International Nuclear Information System (INIS)

    Paolisso, G.; Scheen, A.J.; Luyckx, A.S.; Lefebvre, P.J.

    1987-01-01

    To study the metabolic effects of pulsatile glucagon administration, six male volunteers were submitted to a 260-min glucose-controlled glucose intravenous infusion using the Biostator. The endogenous secretion of the pancreatic hormones was inhibited by somatostatin, basal insulin secretion was replaced by a continuous insulin infusion, and glucagon was infused intravenously in two conditions at random: either continuously or intermittently. Blood glucose levels and glucose infusion rate were monitored continuously by the Biostator, and classical methodology using a D-[3- 3 H]glucose infusion allowed the authors to study glucose turnover. While basal plasma glucagon levels were similar in both conditions, they plateaued at 189 +/- 38 pg ml -1 during continuous infusion and varied between 95 and 501 pg x ml -1 during pulsatile infusion. When compared with continuous administration, pulsatile glucagon infusion 1) initially induced a similar increase in endogenous (hepatic) glucose production and blood glucose, 2) did not prevent the so-called evanescent effect of glucagon on blood glucose, and 3) after 3 h tended to reduce rather than increase hepatic glucose production. In conclusion, in vivo pulsatile hyperglucanemia in normal man fails to increase hepatic glucose production

  4. Effect of degree of lipomobilization on results of glucose test in dairy cows in heat stress

    Directory of Open Access Journals (Sweden)

    Cincović M.R.

    2012-01-01

    Full Text Available Cows exposed to heat stress exhibit a decreased ability to mobilize lipids due to increased sensitivity to insulin, which is expressed in a decreased concentration of NEFA. However, certain cows can preserve the level of lipid mobilization after adapting to heat stress. We assumed that cows that have a preserved ability to mobilize lipids are less sensitive to insulin and that they have a lower tolerance for glucose. The aim of this work was to compare the results of an intravenous glucose tolerance test in cows that exhibited, in prolonged heat stress, a decreased (NEFA0.30 mmol/l ability for lipid mobilization. Glucose concentration and NEFA concentration were measured following intravenous application of glucose. The mean glycaemic index value did not differ statistically significantly between the two groups of cows at 10, 15 and 20 minutes after glucose application (p>0.05, but there was a tendency at 10 and 15 minutes for the glycaemia to be higher in cows with preserved lipomobilization (p<0.1. At 30, 60 and 90 minutes after glucose application, glycaemia was statistically significantly higher (p<0.01; p<0.05 and p<0.05 in the group of cows with preserved lipomobilization. The glycaemic index values (mmol/l shown in the same order (30, 60 and 90 minutes were as follows 9.91±0.21: 9.23±0.41; 5.41±0.5: 4.67±0.33 and 4.31±0.39: 3.47±0.37. The mean value for NEFA concentration in samples originating from the two experimental groups of cows did not differ statistically significantly following glucose application. The NEFA concentration showed a tendency to be higher in cows with preserved lipid mobilization in comparison with cows with decreased lipomobilization at 20 and 30 minutes after glucose application (p<0.1. Following the intravenous glucose tolerance test, NEFA and glucose concentrations were in a significant negative correlation, and that correlation was more expressed in cows with decreased lipomobilization. Cows with preserved

  5. Monitoring of glucose levels in mouse blood with noninvasive optical methods

    International Nuclear Information System (INIS)

    Ullah, H; Ikram, M; Ahmed, E

    2014-01-01

    We report the quantification/monitoring of glucose levels in a blood sample using optical diffuse reflectance (ODR) underlying variations in optical parameters with a white light source (at peak wavelength ∼600 nm and range 450–850 nm) and in blood in vivo using M-mode optical coherence tomography (OCT) in terms of the translational diffusion coefficient (D T ). In the ODR experiments, we have investigated two types of mono-dispersive particles, i.e. polystyrene microspheres (PMSs) with diameters of 1.4 μm (variable concentrations) and 2.6 μm (fixed concentration) in a water phantom by observing changes in the reduced scattering coefficient. We believe that these differences in optical properties will be helpful for the understanding and optimal use of laser applications in blood glucometry without piercing the skin. In the OCT experiments, this idea of glucose monitoring was applied on an in vivo normal mouse without injection of glucose intravenously to provide the threshold levels by envisioning/identifying a blood vessel by speckle variance (SV-OCT) using a dorsal skinfold mouse windows chamber model. We report an average value of translation decorrelation time τ T = 41.18 ± 1.92 ms and D T = 8.90 × 10 −14  m 2  s −1 underlying the dynamic light scattering (DLS). Our results have a potential application in the quantification of higher glucose levels in vivo administrated intravenously. (paper)

  6. Clinical assessment of blood glucose homeostasis in horses: comparison of a continuous glucose monitoring system with a combined intravenous glucose and insulin test protocol.

    Science.gov (United States)

    Johnson, P J; Wiedmeyer, C E; LaCarrubba, A; Messer, N T; Dingfelder, H A; Cogswell, A M; Amorim, J R R; Ganjam, V K

    2011-01-01

    The combined glucose-insulin test (CGIT) is helpful for evaluating insulin sensitivity. A continuous glucose monitoring system (CGMS) reports changes in interstitial glucose concentrations as they occur in the blood. Use of the CGMS minimizes animal contact and may be useful when performing a CGIT. Results obtained using a CGMS are useful for the evaluation of glucose responses during the evaluation of insulin sensitivity in equids. Seven mature, obese ponies. Ponies were equipped with CGMS for determination of interstitial glucose concentrations. Glucose (150 mg/kg, i.v.) and insulin (0.1 U/kg, i.v.) were administered and blood glucose concentrations determined at (minutes after time zero) 1, 5, 15, 25, 35, 45, 60, 75, 90, 105, and 120 with a hand-held glucometer. Blood chemistry results were compared with simultaneously obtained results using CGMS. Concordance coefficients determined for comparison of blood glucose concentrations determined by a hand-held glucometer and those determined by CGMS after the zero time point were 0.623, 0.764, 0.834, 0.854, and 0.818 (for delays of 0, 5, 10, 15, and 20 minutes, respectively). Interstitial glucose concentrations obtained by the CGMS compared favorably to blood glucose concentrations. CGMS may be useful for assessment of glucose dynamics in the CGIT. Copyright © 2010 by the American College of Veterinary Internal Medicine.

  7. Determination of 24-hour insulin infusion pattern by an artificial endocrine pancreas for intravenous insulin infusion with a miniature pump

    DEFF Research Database (Denmark)

    Kølendorf, K; Christiansen, J S; Bojsen, J

    1981-01-01

    UNLABELLED: Intravenous insulin infusion with a glucose controlled insulin infusion system (GCIIS) is known to restore glucose homeostasis. A simpler approach to improve blood glucose regulation is preprogrammed intravenous insulin infusion with portable pumps without sensor-mediated feedback. We...... report a study designed to evaluate whether the preprogrammed insulin infusion pattern to be used in the miniature insulin infusion pump (MIIP) could be optimized by concomitant employment of the GCIIS for blood glucose control. Six juvenile-onset insulin-dependent diabetics (mean age 31 yrs) were...... studied. Mean blood glucose (MBG) was 6.2 mmol/l +/- 0.5 (SD) during glucose controlled infusion and 5.3 +/- 0.6 during the combined MIIP + GCIIS-day. The insulin requirements calculated from the s.c. regimen (56 U +/- 10 SD) were identical to the GCIIS-measured (51 U +/- 14) and to the amounts delivered...

  8. The glucose oxidase-peroxidase assay for glucose

    Science.gov (United States)

    The glucose oxidase-peroxidase assay for glucose has served as a very specific, sensitive, and repeatable assay for detection of glucose in biological samples. It has been used successfully for analysis of glucose in samples from blood and urine, to analysis of glucose released from starch or glycog...

  9. Intraoperative glucose management in children < 1 year or < 10 kg ...

    African Journals Online (AJOL)

    The intraoperative management of intravenous dextrose administration and blood glucose monitoring was at the discretion of the attending anaesthetists. Data collected included patient demographics, period of starvation, dose of dextrose administered and blood glucose measurements taken. Results: Nine infants had at ...

  10. Stability studies of lincomycin hydrochloride in aqueous solution and intravenous infusion fluids

    Directory of Open Access Journals (Sweden)

    Czarniak P

    2016-03-01

    Full Text Available Petra Czarniak, Michael Boddy, Bruce Sunderland, Jeff D Hughes School of Pharmacy, Curtin University, Perth, WA, Australia Purpose: The purpose of this study was to evaluate the chemical stability of Lincocin® (lincomycin hydrochloride in commonly used intravenous fluids at room temperature (25°C, at accelerated-degradation temperatures and in selected buffer solutions.Materials and methods: The stability of Lincocin® injection (containing lincomycin 600 mg/2 mL as the hydrochloride stored at 25°C±0.1°C in sodium lactate (Hartmann’s, 0.9% sodium chloride, 5% glucose, and 10% glucose solutions was investigated over 31 days. Forced degradation of Lincocin® in hydrochloric acid, sodium hydroxide, and hydrogen peroxide was performed at 60°C. The effect of pH on the degradation rate of lincomycin hydrochloride stored at 80°C was determined.Results: Lincomycin hydrochloride was found to maintain its shelf life at 25°C in sodium lactate (Hartmann’s solution, 0.9% sodium chloride solution, 5% glucose solution, and 10% glucose solution, with less than 5% lincomycin degradation occurring in all intravenous solutions over a 31-day period. Lincomycin hydrochloride showed less rapid degradation at 60°C in acid than in basic solution, but degraded rapidly in hydrogen peroxide. At all pH values tested, lincomycin followed first-order kinetics. It had the greatest stability near pH 4 when stored at 80°C (calculated shelf life of 4.59 days, and was least stable at pH 2 (calculated shelf life of 0.38 days.Conclusion: Lincocin® injection was chemically found to have a shelf life of at least 31 days at 25°C when added to sodium lactate (Hartmann’s solution, 0.9% sodium chloride solution, 5% glucose solution, and 10% glucose solution. Solutions prepared at approximately pH 4 are likely to have optimum stability. Keywords: lincomycin, stability, pH, intravenous fluids, IV additives

  11. Insulin and GH signaling in human skeletal muscle in vivo following exogenous GH exposure: impact of an oral glucose load.

    Directory of Open Access Journals (Sweden)

    Thomas Krusenstjerna-Hafstrøm

    2011-05-01

    Full Text Available GH induces acute insulin resistance in skeletal muscle in vivo, which in rodent models has been attributed to crosstalk between GH and insulin signaling pathways. Our objective was to characterize time course changes in signaling pathways for GH and insulin in human skeletal muscle in vivo following GH exposure in the presence and absence of an oral glucose load.Eight young men were studied in a single-blinded randomized crossover design on 3 occasions: 1 after an intravenous GH bolus 2 after an intravenous GH bolus plus an oral glucose load (OGTT, and 3 after intravenous saline plus OGTT. Muscle biopsies were taken at t = 0, 30, 60, and 120. Blood was sampled at frequent intervals for assessment of GH, insulin, glucose, and free fatty acids (FFA.GH increased AUC(glucose after an OGTT (p<0.05 without significant changes in serum insulin levels. GH induced phosphorylation of STAT5 independently of the OGTT. Conversely, the OGTT induced acute phosphorylation of the insulin signaling proteins Akt (ser(473 and thr(308, and AS160.The combination of OGTT and GH suppressed Akt activation, whereas the downstream expression of AS160 was amplified by GH. WE CONCLUDED THE FOLLOWING: 1 A physiological GH bolus activates STAT5 signaling pathways in skeletal muscle irrespective of ambient glucose and insulin levels 2 Insulin resistance induced by GH occurs without a distinct suppression of insulin signaling proteins 3 The accentuation of the glucose-stimulated activation of AS 160 by GH does however indicate a potential crosstalk between insulin and GH.ClinicalTrials.gov NCT00477997.

  12. Measurement of glucose area under the curve using minimally invasive interstitial fluid extraction technology: evaluation of glucose monitoring concepts without blood sampling.

    Science.gov (United States)

    Sato, Toshiyuki; Okada, Seiki; Hagino, Kei; Asakura, Yoshihiro; Kikkawa, Yasuo; Kojima, Junko; Watanabe, Toshihiro; Maekawa, Yasunori; Isobe, Kazuki; Koike, Reona; Nakajima, Hiromu; Asano, Kaoru

    2011-12-01

    Monitoring postprandial hyperglycemia is crucial in treating diabetes, although its dynamics make accurate monitoring difficult. We developed a new technology for monitoring postprandial hyperglycemia using interstitial fluid (ISF) extraction technology without blood sampling. The glucose area under the curve (AUC) using this system was measured as accumulated ISF glucose (IG) with simultaneous calibration with sodium ions. The objective of this study was to evaluate this technological concept in healthy individuals. Minimally invasive ISF extraction technology (MIET) comprises two steps: pretreatment with microneedles and ISF accumulation over a specific time by contact with a solvent. The correlation between glucose and sodium ion levels using MIET was evaluated in 12 subjects with stable blood glucose (BG) levels during fasting. BG and IG time courses were evaluated in three subjects to confirm their relationship while BG was fluctuating. Furthermore, the accuracy of glucose AUC measurements by MIET was evaluated several hours after a meal in 30 subjects. A high correlation was observed between glucose and sodium ion levels when BG levels were stable (R=0.87), indicating that sodium ion is a good internal standard for calibration. The variation in IG and BG with MIET was similar, indicating that IG is an adequate substitute for BG. Finally, we showed a strong correlation (R=0.92) between IG-AUC and BG-AUC after a meal. These findings validate the adequacy of glucose AUC measurements using MIET. Monitoring glucose using MIET without blood sampling may be beneficial to patients with diabetes.

  13. Influence of partial pressure of oxygen in blood samples on measurement performance in glucose-oxidase-based systems for self-monitoring of blood glucose.

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-11-01

    Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Aliquots of 20 venous samples were adjusted to the following pO2 values: oxygen sensitive. © 2013 Diabetes Technology Society.

  14. The immediate effects of a single bout of aerobic exercise on oral glucose tolerance across the glucose tolerance continuum

    DEFF Research Database (Denmark)

    Knudsen, Sine H; Karstoft, Kristian; Pedersen, Bente K

    2014-01-01

    We investigated glucose tolerance and postprandial glucose fluxes immediately after a single bout of aerobic exercise in subjects representing the entire glucose tolerance continuum. Twenty-four men with normal glucose tolerance (NGT), impaired glucose tolerance (IGT), or type 2 diabetes (T2D; age......: 56 ± 1 years; body mass index: 27.8 ± 0.7 kg/m(2), P > 0.05) underwent a 180-min oral glucose tolerance test (OGTT) combined with constant intravenous infusion of [6,6-(2)H2]glucose and ingestion of [U-(13)C]glucose, following 1 h of exercise (50% of peak aerobic power) or rest. In both trials......OGTT, and Rd (all P value in NGT subjects when compared to IGT and T2D subjects. Accordingly, following exercise, the plasma glucose concentration during the OGTT was increased in NGT subjects (P

  15. Optimal glucose management in the perioperative period.

    Science.gov (United States)

    Evans, Charity H; Lee, Jane; Ruhlman, Melissa K

    2015-04-01

    Hyperglycemia is a common finding in surgical patients during the perioperative period. Factors contributing to poor glycemic control include counterregulatory hormones, hepatic insulin resistance, decreased insulin-stimulated glucose uptake, use of dextrose-containing intravenous fluids, and enteral and parenteral nutrition. Hyperglycemia in the perioperative period is associated with increased morbidity, decreased survival, and increased resource utilization. Optimal glucose management in the perioperative period contributes to reduced morbidity and mortality. To readily identify hyperglycemia, blood glucose monitoring should be instituted for all hospitalized patients. Published by Elsevier Inc.

  16. A comparison between the minimal model and the glucose clamp in the assessment of insulin sensitivity across the spectrum of glucose tolerance. Insulin Resistance Atherosclerosis Study.

    Science.gov (United States)

    Saad, M F; Anderson, R L; Laws, A; Watanabe, R M; Kades, W W; Chen, Y D; Sands, R E; Pei, D; Savage, P J; Bergman, R N

    1994-09-01

    An insulin-modified frequently sampled intravenous glucose tolerance test (FSIGTT) with minimal model analysis was compared with the glucose clamp in 11 subjects with normal glucose tolerance (NGT), 20 with impaired glucose tolerance (IGT), and 24 with non-insulin-dependent diabetes mellitus (NIDDM). The insulin sensitivity index (SI) was calculated from FSIGTT using 22- and 12-sample protocols (SI(22) and SI(12), respectively). Insulin sensitivity from the clamp was expressed as SI(clamp) and SIP(clamp). Minimal model parameters were similar when calculated with SI(22) and SI(12). SI could not be distinguished from 0 in approximately 50% of diabetic patients with either protocol. SI(22) correlated significantly with SI(clamp) in the whole group (r = 0.62), and in the NGT (r = 0.53), IGT (r = 0.48), and NIDDM (r = 0.41) groups (P SIP(clamp) were expressed in the same units, SI(22) was 66 +/- 5% (mean +/- SE) and 50 +/- 8% lower than SI(clamp) and SIP(clamp), respectively. Thus, minimal model analysis of the insulin-modified FSIGTT provides estimates of insulin sensitivity that correlate significantly with those from the glucose clamp. The correlation was weaker, however, in NIDDM. The insulin-modified FSIGTT can be used as a simple test for assessment of insulin sensitivity in population studies involving nondiabetic subjects. Additional studies are needed before using this test routinely in patients with NIDDM.

  17. Blood gas sample spiking with total parenteral nutrition, lipid emulsion, and concentrated dextrose solutions as a model for predicting sample contamination based on glucose result.

    Science.gov (United States)

    Jara-Aguirre, Jose C; Smeets, Steven W; Wockenfus, Amy M; Karon, Brad S

    2018-05-01

    Evaluate the effects of blood gas sample contamination with total parenteral nutrition (TPN)/lipid emulsion and dextrose 50% (D50) solutions on blood gas and electrolyte measurement; and determine whether glucose concentration can predict blood gas sample contamination with TPN/lipid emulsion or D50. Residual lithium heparin arterial blood gas samples were spiked with TPN/lipid emulsion (0 to 15%) and D50 solutions (0 to 2.5%). Blood gas (pH, pCO2, pO2), electrolytes (Na+, K+ ionized calcium) and hemoglobin were measured with a Radiometer ABL90. Glucose concentration was measured in separated plasma by Roche Cobas c501. Chart review of neonatal blood gas results with glucose >300 mg/dL (>16.65 mmol/L) over a seven month period was performed to determine whether repeat (within 4 h) blood gas results suggested pre-analytical errors in blood gas results. Results were used to determine whether a glucose threshold could predict contamination resulting in blood gas and electrolyte results with greater than laboratory-defined allowable error. Samples spiked with 5% or more TPN/lipid emulsion solution or 1% D50 showed glucose concentration >500 mg/dL (>27.75 mmol/L) and produced blood gas (pH, pO 2 , pCO 2 ) results with greater than laboratory-defined allowable error. TPN/lipid emulsion, but not D50, produced greater than allowable error in electrolyte (Na + ,K + ,Ca ++ ,Hb) results at these concentrations. Based on chart review of 144 neonatal blood gas results with glucose >250 mg/dL received over seven months, four of ten neonatal intensive care unit (NICU) patients with glucose results >500 mg/dL and repeat blood gas results within 4 h had results highly suggestive of pre-analytical error. Only 3 of 36 NICU patients with glucose results 300-500 mg/dL and repeat blood gas results within 4 h had clear pre-analytical errors in blood gas results. Glucose concentration can be used as an indicator of significant blood sample contamination with either TPN

  18. Altered glucose kinetics in diabetic rats during Gram-negative infection

    International Nuclear Information System (INIS)

    Lang, C.H.; Dobrescu, C.; Bagby, G.J.; Spitzer, J.J.

    1987-01-01

    The present study examined the purported exacerbating effect of sepsis on glucose metabolism in diabetes. Diabetes was induced in rats by an intravenous injection of 70 or 45 mg/kg streptozotocin. The higher dose produced severe diabetes, whereas the lower dose of streptozotocin produced a miler, latent diabetes. After a chronic diabetic state had developed for 4 wk, rats had catheters implanted and sepsis induced by intraperitoneal injections of live Escherichia coli. After 24 h of sepsis the blood glucose concentration was unchanged in nondiabetics and latent diabetics, but glucose decreased from 15 to 8 mM in the septic severe diabetic group. This decrease in blood glucose was not accompanied by alterations in the plasma insulin concentration. Glucose turnover, assessed by the constant intravenous infusion of [6- 3 H]- and [U- 14 C]glucose, was elevated in the severe diabetic group, compared with either latent diabetics or nondiabetics. Sepsis increased the rate of glucose disappearance in nondiabetic rats but had no effect in either group of diabetic animals. Sepsis also failed to alter the insulinogenic index, used to estimate the insulin secretory capacity, in diabetic rats. Thus the present study suggests that the imposition of nonlethal Gram-negative sepsis on severe diabetic animals does not further impair glucose homeostasis and that the milder latent diabetes was not converted to a more severe diabetic state by the septic challenge

  19. Effects of Cr methionine on glucose metabolism, plasma metabolites, meat lipid peroxidation, and tissue chromium in Mahabadi goat kids.

    Science.gov (United States)

    Emami, A; Ganjkhanlou, M; Zali, A

    2015-03-01

    This study was designed to investigate the effects of chromium methionine (Cr-Met) on glucose metabolism, blood metabolites, meat lipid peroxidation, and tissue chromium (Cr) in Mahabadi goat kids. Thirty-two male kids (16.5 ± 2.8 kg BW, 4-5 months of age) were fed for 90 days in a completely randomized design with four treatments. Treatments were supplemented with 0 (control), 0.5, 1, and 1.5 mg Cr as Cr-Met/animal/daily. Blood samples were collected via heparin tubes from the jugular vein on 0, 21, 42, 63, and 90 days of experiment. On day 70, an intravenous glucose tolerance test (IVGTT) was conducted. At the end of the feeding trial, the kids were slaughtered, and the liver, kidney, and longissimus dorsi (LD) muscle samples were collected. Plasma glucose, insulin, and triglyceride concentrations were decreased by Cr supplementation (P glucose concentrations at 30 and 60 min after glucose infusion were lower in the kids fed 1.5 mg Cr diet than the kids fed control diet (P glucose clearance rate (K) and lower glucose half-life (T½; P Glucose area under the response curve (AUC) from 0 to 180 min after glucose infusion was decreased linearly (P glucose utilization and lipid oxidation of meat in fattening kid.

  20. Parsing glucose entry into the brain: novel findings obtained with enzyme-based glucose biosensors.

    Science.gov (United States)

    Kiyatkin, Eugene A; Wakabayashi, Ken T

    2015-01-21

    Extracellular levels of glucose in brain tissue reflect dynamic balance between its gradient-dependent entry from arterial blood and its use for cellular metabolism. In this work, we present several sets of previously published and unpublished data obtained by using enzyme-based glucose biosensors coupled with constant-potential high-speed amperometry in freely moving rats. First, we consider basic methodological issues related to the reliability of electrochemical measurements of extracellular glucose levels in rats under physiologically relevant conditions. Second, we present data on glucose responses induced in the nucleus accumbens (NAc) by salient environmental stimuli and discuss the relationships between local neuronal activation and rapid glucose entry into brain tissue. Third, by presenting data on changes in NAc glucose induced by intravenous and intragastric glucose delivery, we discuss other mechanisms of glucose entry into the extracellular domain following changes in glucose blood concentrations. Lastly, by showing the pattern of NAc glucose fluctuations during glucose-drinking behavior, we discuss the relationships between "active" and "passive" glucose entry to the brain, its connection to behavior-related metabolic activation, and the possible functional significance of these changes in behavioral regulation. These data provide solid experimental support for the "neuronal" hypothesis of neurovascular coupling, which postulates the critical role of neuronal activity in rapid regulation of vascular tone, local blood flow, and entry of glucose and oxygen to brain tissue to maintain active cellular metabolism.

  1. Continuous Glucose Monitoring in the Cardiac ICU: Current Use and Future Directions.

    Science.gov (United States)

    Scrimgeour, Laura A; Potz, Brittany A; Sellke, Frank W; Abid, M Ruhul

    2017-11-01

    Perioperative glucose control is highly important, particularly for patients undergoing cardiac surgery. Variable glucose levels before, during and after cardiac surgery lead to increased post-operative complications and patient mortality. [1] Current methods for intensive monitoring and treating hyperglycemia in the Intensive Care Unit (ICU) usually involve hourly glucose monitoring and continuous intravenous insulin infusions. With the advent of more accurate subcutaneous glucose monitoring systems, the role of improved glucose control with newer systems deserves consideration for widespread adoption.

  2. Glucose turnover during insulin-induced hypoglycemia in liver-denervated rats

    DEFF Research Database (Denmark)

    Mikines, K J; Sonne, B; Richter, Erik

    1985-01-01

    The role of hepatic autonomic nerves in glucose production during hypoglycemia was studied. Selective, surgical denervation of the liver was performed in rats, which reduced hepatic norepinephrine concentrations by 96%. Hypoglycemia was induced by 250 mU of insulin intra-arterially in anesthetized...... as well as in chronically catheterized, awake rats. Half of the anesthetized denervated or sham-operated rats had previously been adrenodemedullated. Glucose turnover was measured by primed, constant intravenous infusion of [3-3H]glucose. Before as well as during hypoglycemia the arterial glucose...

  3. Intravenous supplementation of acetate, glucose or essential amino acids to an energy and protein deficient diet in lactating dairy goats

    DEFF Research Database (Denmark)

    Safayi, S.; Nielsen, M. O.

    2013-01-01

    amino acid supply is suboptimal. Goats were fed a basal diet deficient in energy (90% of requirements) and protein (80% of requirements), and were randomly allocated to 4 treatments in a balanced 4 x 4 Latin square design. The treatments consisted of 4-d continuous intravenous infusions of isoosmotic...... and close to significantly by ACE, but not by GLU treatment. GLU reduced milk protein percentage compared to all other treatments. High milk protein yields on EM and ACE treatments were associated with higher arterial AVD for acetate and oxygen (not significant for ACE), and higher AVD also for beta......In the present experiment we aimed to study, if milk synthesis is more sensitive toward deficiency in supply of amino acids in early (EL) versus late lactation (LL), and if energy yielding substrates in the form of acetate (but not glucose) can contribute to sustain milk (protein) synthesis, when...

  4. INFLUENCE OF PREGNANCY AND LACTATION ON GLUCOSE METABOLISM OF NUBIAN GOATS

    Directory of Open Access Journals (Sweden)

    J. Chávez

    2009-06-01

    Full Text Available Two in vivo metabolic challenges were conducted to assess the changes in glucose metabolism during three intervals prepartum (-6, -4, -2 weeks and three postpartum (+2, +4, +6 weeks in six multiparous pregnant Nubian goats. Challenges consisted of intravenous administration of 1 glucose (62.5 g/goat and 2 L-epinephrine (0.7 mg/kg body weight. Blood samples were collected via jugular cannula from 30 min pre-injection (basal concentrations to four hours post-injection. Response variables for glucose challenge were glucose concentration at zero time (to glucose disappearance rate (t½, insulin and NEFA concentrations; for the epinephrine challenge glucose, NEFA and insulin integrated responses were determined through the four hours of sampling. Data were analyzed according to a repeated-measures design. Dry matter intakes (1.8±0.07 kg/d were not different throughout the study (P>0.1. Average milk production (649±69 g/d was not different among periods (P>0.1. Basal glucose and insulin concentrations were not different (P>0.1 between pregnancy and lactation, with means (± standard error of 77.9±3.7mg/dl, and 0.264±.034ng/dl, respectively. Basal NEFA concentrations were greater (P0.1 and for t½ of 31±15 min (P>0.1. Insulin responses were similar for all periods (63.3±8.2 ngml-1min (P>0.1. The epinephrine challenge resulted in similar changes in glucose and insulin integrated responses throughout the periods evaluated (P>0.1, with corresponding means for glucose of 3886.5±318 mgml-1min, and 21.6±7.7 ngml-1min, but elicited a significant (P

  5. Glucose tolerance, insulin release, and insulin binding to monocytes in kidney transplant recipients

    International Nuclear Information System (INIS)

    Briggs, W.A.; Wielechowski, K.S.; Mahajan, S.K.; Migdal, S.D.; McDonald, F.D.

    1982-01-01

    In order to evaluate glucose tolerance following renal transplantation, intravenous glucose tolerance tests (IVGTT), with evaluation of hormonal responses to the intravenous glucose load and percent specific 125 I-insulin binding to peripheral blood monocytes, were studied in eight clinically stable kidney transplant recipients. For comparison purposes, identical studies were done in eight control subjects and seven clinically stable hemodialysis patients. One transplant recipient was glucose intolerant, with fasting hyperglycemia, elevated HbA1C, and abnormal glucose decay constant. Impaired pancreatic insulin release appeared to be the major factor accounting for his glucose intolerance. The seven glucose-tolerant transplant recipients had significantly increased insulin release during IVGTT compared to control subjects, and significant correlations were found among insulin release, glucose decay constant, and fasting blood sugar in those patients. Insulin binding to monocytes was significantly greater in transplant recipients than control subjects due to an increase in insulin binding capacity per cell. A significant correlation was found between percent specific 125 I-insulin binding and steroid dose, expressed as mg/kg body weight/day, in those patients. Thus, chronic steroid administration does not cause glucose intolerance in transplant recipients who manifest steroid-associated increases in pancreatic insulin release and cellular insulin binding capacity

  6. Intravenous injection of ioxilan, iohexol and diatrizoate

    International Nuclear Information System (INIS)

    Thomsen, H.S.; Dorph, S.; Mygind, T.; Sovak, M.; Nielsen, H.; Rygaard, H.; Larsen, S.; Skaarup, P.; Hemmingsen, L.; Holm, J.

    1988-01-01

    Effects of intravenous ioxilan, a new third generation non-ionic contrast medium, diatrizoate, iohexol and saline on urine profiles were compared. Albumin, glucose, sodium, phosphate, and the enzymes NAG, LDH and GGT were followed in 24 normal rats over 7 days. Diatrizoate significantly affected all profile components during the first two hours. Albuminuria was significantly greater after diatrizoate than after iohexol or ioxilan, and excretion of glucose, LDH and GGT was significantly higher than after ioxilan. Both iohexol and ioxilan increased the excretion of albumin, LDH and GGT, while iohexol also significantly increased excretion of glucose and sodium. There was a greater excretion of glucose and GGT after iohexol than after ioxilan. Saline did not induce any changes. At day 7, serum sodium, urea, creatinine, and albumin were normal for all test substances, and kidney histology revealed no difference between the groups of animals. It is thus concluded that both high osmolar ionic and low osmolar non-ionic contrast media may cause temporary glomerular and tubular dysfunction in rats. In this model, the kidney is affected most by diatrizoate, less by iohexol, and least by ioxilan. (orig.)

  7. Effect of Intravenous Small-Volume Hypertonic Sodium Bicarbonate, Sodium Chloride, and Glucose Solutions in Decreasing Plasma Potassium Concentration in Hyperkalemic Neonatal Calves with Diarrhea.

    Science.gov (United States)

    Trefz, F M; Constable, P D; Lorenz, I

    2017-05-01

    Hyperkalemia is a frequently observed electrolyte imbalance in dehydrated neonatal diarrheic calves that can result in skeletal muscle weakness and life-threatening cardiac conduction abnormalities and arrhythmias. Intravenous administration of a small-volume hypertonic NaHCO 3 solution is clinically more effective in decreasing the plasma potassium concentration (cK) in hyperkalemic diarrheic calves than hypertonic NaCl or glucose solutions. Twenty-two neonatal diarrheic calves with cK >5.8 mmol/L. Prospective randomized clinical trial. Calves randomly received either 8.4% NaHCO 3 (6.4 mL/kg BW; n = 7), 7.5% NaCl (5 mL/kg BW; n = 8), or 46.2% glucose (5 mL/kg BW; n = 7) IV over 5 minutes and were subsequently allowed to suckle 2 L of an electrolyte solution. Infusions with NaHCO 3 and NaCl provided an identical sodium load of 6.4 mmol/kg BW. Hypertonic NaHCO 3 infusions produced an immediate and sustained decrease in plasma cK. Hypertonic glucose infusions resulted in marked hyperglycemia and hyperinsulinemia, but cK remained unchanged for 20 minutes. Between 30 and 120 minutes after initiation of treatment, the most marked decrements in cK from baseline occurred in group NaHCO 3 , which were significantly (P < .05) larger during this period of time than in calves in group NaCl, but not group glucose. After 120 minutes, the mean decrease in cK from baseline was -26 ± 10%, -9 ± 8%, and -22 ± 6% in groups NaHCO 3 , NaCl, and glucose, respectively. Small-volume hypertonic NaHCO 3 infusions appear to have clinical advantages for the rapid resuscitation of hyperkalemic diarrheic calves, compared to hypertonic NaCl or glucose solutions. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  8. Correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer and serum glucose concentration measured by an automated biochemical analyzer for canine and feline blood samples.

    Science.gov (United States)

    Tauk, Barbara S; Drobatz, Kenneth J; Wallace, Koranda A; Hess, Rebecka S

    2015-06-15

    To investigate the correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer (POCG) and serum glucose concentration measured by a biochemical analyzer. Prospective clinical study. 96 blood samples from 80 dogs and 90 blood samples from 65 cats. Serum, plasma, and whole blood were obtained from each blood sample. The glucose concentrations in serum, plasma, and whole blood measured by a POCG were compared with the serum glucose concentration measured by a biochemical analyzer by use of the Lin concordance correlation coefficient (ρc) and Bland-Altman plots. For both canine and feline samples, glucose concentrations in serum and plasma measured by the POCG were more strongly correlated with the serum glucose concentration measured by the biochemical analyzer (ρc, 0.98 for both canine serum and plasma; ρc, 0.99 for both feline serum and plasma) than was that in whole blood (ρc, 0.62 for canine samples; ρc, 0.90 for feline samples). The mean difference between the glucose concentrations determined by the biochemical analyzer and the POCG in serum, plasma, and whole blood was 0.4, 0.3, and 31 mg/dL, respectively, for canine samples and 7, 6, and 32 mg/dL, respectively, for feline samples. Results indicated that use of a POCG to measure glucose concentrations in serum or plasma may increase the accuracy and reliability of diagnostic and treatment decisions associated with glucose homeostasis disorders in dogs and cats.

  9. Effect of rapid intravenous administration of 50% dextrose solution on phosphorus homeostasis in postparturient dairy cows.

    Science.gov (United States)

    Grünberg, Walter; Morin, Dawn E; Drackley, James K; Constable, Peter D

    2006-01-01

    Dextrose is commonly administered to postparturient dairy cows, which often have low plasma phosphorus concentration ([P]) as a result of anorexia and sudden onset of lactation. Intravenous (IV) dextrose administration causes hypophosphatemia in other species. Bolus administration of dextrose to postparturient dairy cows results in a transient decrease in plasma [P]. Six healthy postparturient dairy cows. Using a crossover design, cows were administered 500 mL of 50% dextrose solution IV or a sham treatment. Plasma concentrations of glucose ([glucose]), immunoreactive insulin ([IRI]), and phosphorus were monitored for 12 hours after each treatment. Urine [P], [glucose], and volume and salivary [P] were also determined. Plasma [glucose], [IRI], and [P] were stable during sham treatment. Plasma [P] decreased rapidly after dextrose administration, dropping by 35% in 1 hour and remaining below baseline for 90 minutes. Salivary [P], urine [P], and urine volume per hour remained stable after dextrose administration, but glucose was detected in urine for up to 6 hours. The amount of glucose excreted in urine in 12 hours (11.9+/-4.5 g) was less than 5% of the administered dose. Regression analysis revealed a stronger association between plasma [P] and [IRI] than between plasma [P] and [glucose], suggesting that hyperinsulinemia drove the hypophosphatemia. Results indicate that low plasma [P] should be expected in cows that have received IV dextrose within 1 hour before blood sampling. Caution is advised when administering dextrose solution to cows already at risk of hypophosphatemia.

  10. A novel glucose biosensor based on phosphonic acid-functionalized silica nanoparticles for sensitive detection of glucose in real samples

    International Nuclear Information System (INIS)

    Zhao, Wenbo; Fang, Yi; Zhu, Qinshu; Wang, Kuai; Liu, Min; Huang, Xiaohua; Shen, Jian

    2013-01-01

    An effective strategy for preparation amperometric biosensor by using the phosphonic acid-functionalized silica nanoparticles (PFSi NPs) as special modified materials is proposed. In such a strategy, glucose oxidase (GOD) was selected as model protein to fabricate glucose biosensor in the presence of phosphonic acid-functionalized silica nanoparticles (PFSi NPs). The PFSi NPs were first modified on the surface of glassy carbon (GC) electrode, then, GOD was adsorbed onto the PFSi NPs film by drop-coating. The PFSi NPs were characterized by transmission electron microscopy (TEM) and nuclear magnetic resonance (NMR) spectra. The interaction of PFSi NPs with GOD was investigated by the circular dicroism spectroscopy (CD). The results showed PFSi NPs could essentially maintain the native conformation of GOD. The direct electron transfer of GOD on (PFSi NPs)/GCE electrode exhibited excellent electrocatalytic activity for the oxidation of glucose. The proposed biosensor modified with PFSi NPs displayed a fast amperometric response (5 s) to glucose, a good linear current–time relation over a wide range of glucose concentrations from 5.00 × 10 −4 to 1.87 × 10 −1 M, and a low detection limit of 2.44 × 10 −5 M (S/N = 3). Moreover, the biosensor can be used for assessment of the concentration of glucose in many real samples (relative error < 3%). The GOD biosensor modified with PFSi NPs will have essential meaning and practical application in future that attributed to the simple method of fabrication and good performance

  11. Computer Simulation Model to Train Medical Personnel on Glucose Clamp Procedures.

    Science.gov (United States)

    Maghoul, Pooya; Boulet, Benoit; Tardif, Annie; Haidar, Ahmad

    2017-10-01

    A glucose clamp procedure is the most reliable way to quantify insulin pharmacokinetics and pharmacodynamics, but skilled and trained research personnel are required to frequently adjust the glucose infusion rate. A computer environment that simulates glucose clamp experiments can be used for efficient personnel training and development and testing of algorithms for automated glucose clamps. We built 17 virtual healthy subjects (mean age, 25±6 years; mean body mass index, 22.2±3 kg/m 2 ), each comprising a mathematical model of glucose regulation and a unique set of parameters. Each virtual subject simulates plasma glucose and insulin concentrations in response to intravenous insulin and glucose infusions. Each virtual subject provides a unique response, and its parameters were estimated from combined intravenous glucose tolerance test-hyperinsulinemic-euglycemic clamp data using the Bayesian approach. The virtual subjects were validated by comparing their simulated predictions against data from 12 healthy individuals who underwent a hyperglycemic glucose clamp procedure. Plasma glucose and insulin concentrations were predicted by the virtual subjects in response to glucose infusions determined by a trained research staff performing a simulated hyperglycemic clamp experiment. The total amount of glucose infusion was indifferent between the simulated and the real subjects (85±18 g vs. 83±23 g; p=NS) as well as plasma insulin levels (63±20 mU/L vs. 58±16 mU/L; p=NS). The virtual subjects can reliably predict glucose needs and plasma insulin profiles during hyperglycemic glucose clamp conditions. These virtual subjects can be used to train personnel to make glucose infusion adjustments during clamp experiments. Copyright © 2017 Diabetes Canada. Published by Elsevier Inc. All rights reserved.

  12. Use of real time continuous glucose monitoring and intravenous insulin in type 1 diabetic mothers to prevent respiratory distress and hypoglycaemia in infants

    Directory of Open Access Journals (Sweden)

    Passaro Patrizia

    2008-07-01

    Full Text Available Abstract Background Pregnancy in Type 1 diabetic patients is a precarious condition, both for mother and fetus with increased the risk of prematurity and, immediately after delivery with risk of respiratory distress syndrome and hypoglycaemia in newborns. A strict control and monitoring of diabetes throughout pregnancy is important in reducing the impact of the disease on the fetus and newborn. In recent years many new technologies have been introduced to ameliorate diabetes monitoring, where the last is the Real-time Continuous Glucose Monitoring System (RT-CGMS. Methods In the last three years, 72 h continuous glucose monitoring system (RT-CGMS (Medtronic, CA was performed in 18 pregnant women with Type 1 diabetes in two moments of pregnancy: during treatment with betamethasone to prevent respiratory distress and during delivery. In both cases insulin was administered intravenous and the dose was changed on the basis of glycaemia. Results The results present the use of this new technique during two topics moments of pregnancy of type 1 diabetes patients when is very important intensively to monitor diabetes and to obtain the well being of the fetus. No infant experimented hypoglycaemia or respiratory distress syndrome at the moment and in the first hours after the birth. Conclusion We wish to stress the importance reducing glycaemia during administration of betamethasone and during labor. It is conceivable that the scarce attention paid to monitoring glucose levels in diabetic mothers during labor in gynaecological world may be due to the difficulty in glucose monitoring with the devices until now available. Hopefully, our anecdotal account may prompt improvements with RT-CGMS, and may lead to a better approach to the problem, thereby changing the prognosis of infants born to diabetic mothers.

  13. The effects of hypoglycin on glucose metabolism in the rat

    International Nuclear Information System (INIS)

    Osmundsen, H.; Billington, D.; Taylor, J.R.; Sherratt, H.S.A.

    1978-01-01

    The kinetics of glucose metabolism were evaluated in rats deprived of food 15 to 21 h after the administration of hypoglycaemic doses of hypoglycin (100 mg/kg body wt.) by following changes in the specific radioactivities of 14 C and 3 H in blood glucose after an intravenous dose of [U- 14 C,2- 3 H]glucose. During this time, recycling of glucose through the Cori cycle was virtually abolished, the rate of irreversible disposal of glucose and its total body mass were both decreased by about 70%, whereas there was little effect on the mean transit time for glucose. It was concluded that hypoglycaemia is due to inhibition of gluconeogenesis. (author)

  14. Amperometric, screen-printed, glucose biosensor for analysis of human plasma samples using a biocomposite water-based carbon ink incorporating glucose oxidase.

    Science.gov (United States)

    Crouch, Eric; Cowell, David C; Hoskins, Stephen; Pittson, Robin W; Hart, John P

    2005-12-01

    This paper describes the optimisation of a screen-printing water-based carbon ink containing cobalt phthalocyanine (CoPC) and glucose oxidase (GOD) for the fabrication of a glucose biosensor. To optimise the performance of the biosensor, the loadings of the electrocatalyst (CoPC) and enzyme (GOD) were varied. It was found that the maximum linear range was achieved with a CoPC loading of 20% (m/m, relative to the mass of carbon) and a GOD loading of 628 U per gram of carbon. In our studies we chose to employ chronoamperometry, as this technique is commonly used for commercial devices. The optimum operating applied potential was found to be +0.5 V, following an incubation period of 60 s. The optimum supporting electrolyte was found to be 0.05 M phosphate buffer at pH 8.0, which resulted in a linear range of 0.2-5 mM, the former represents the detection limit. The sensitivity was 1.12 microA mM(-1). The effect of temperature was also investigated, and it was found that 40 degrees C gave optimal performance. The resulting amperometric biosensors were evaluated by measuring the glucose concentrations for 10 different human plasma samples containing endogenous glucose and also added glucose. The same samples were analysed by a standard spectrophotometric method, and the results obtained by the two different methods were compared. A good correlation coefficient (R(2) = 0.95) and slope (0.98) were calculated from the experimental data, indicating that the new devices hold promise for biomedical studies.

  15. Glucagon suppression during OGTT worsens while suppression during IVGTT sustains alongside development of glucose intolerance in patients with chronic pancreatitis

    DEFF Research Database (Denmark)

    Knop, F K; Vilsbøll, T; Larsen, Steen

    2010-01-01

    To examine plasma glucagon responses to oral and intravenous (iv) glucose in patients with chronic pancreatitis (CP) and either normal glucose tolerance (NGT), secondary impaired glucose tolerance (IGT) or secondary diabetes mellitus (DM)....

  16. Stability studies of lincomycin hydrochloride in aqueous solution and intravenous infusion fluids.

    Science.gov (United States)

    Czarniak, Petra; Boddy, Michael; Sunderland, Bruce; Hughes, Jeff D

    2016-01-01

    The purpose of this study was to evaluate the chemical stability of Lincocin(®) (lincomycin hydrochloride) in commonly used intravenous fluids at room temperature (25°C), at accelerated-degradation temperatures and in selected buffer solutions. The stability of Lincocin(®) injection (containing lincomycin 600 mg/2 mL as the hydrochloride) stored at 25°C±0.1°C in sodium lactate (Hartmann's), 0.9% sodium chloride, 5% glucose, and 10% glucose solutions was investigated over 31 days. Forced degradation of Lincocin(®) in hydrochloric acid, sodium hydroxide, and hydrogen peroxide was performed at 60°C. The effect of pH on the degradation rate of lincomycin hydrochloride stored at 80°C was determined. Lincomycin hydrochloride w as found to maintain its shelf life at 25°C in sodium lactate (Hartmann's) solution, 0.9% sodium chloride solution, 5% glucose solution, and 10% glucose solution, with less than 5% lincomycin degradation occurring in all intravenous solutions over a 31-day period. Lincomycin hydrochloride showed less rapid degradation at 60°C in acid than in basic solution, but degraded rapidly in hydrogen peroxide. At all pH values tested, lincomycin followed first-order kinetics. It had the greatest stability near pH 4 when stored at 80°C (calculated shelf life of 4.59 days), and was least stable at pH 2 (calculated shelf life of 0.38 days). Lincocin(®) injection was chemically found to have a shelf life of at least 31 days at 25°C when added to sodium lactate (Hartmann's) solution, 0.9% sodium chloride solution, 5% glucose solution, and 10% glucose solution. Solutions prepared at approximately pH 4 are likely to have optimum stability.

  17. A comprehensive compartmental model of blood glucose regulation for healthy and type 2 diabetic subjects.

    Science.gov (United States)

    Vahidi, O; Kwok, K E; Gopaluni, R B; Knop, F K

    2016-09-01

    We have expanded a former compartmental model of blood glucose regulation for healthy and type 2 diabetic subjects. The former model was a detailed physiological model which considered the interactions of three substances, glucose, insulin and glucagon on regulating the blood sugar. The main drawback of the former model was its restriction on the route of glucose entrance to the body which was limited to the intravenous glucose injection. To handle the oral glucose intake, we have added a model of glucose absorption in the gastrointestinal tract to the former model to address the resultant variations of blood glucose concentrations following an oral glucose intake. Another model representing the incretins production in the gastrointestinal tract along with their hormonal effects on boosting pancreatic insulin production is also added to the former model. We have used two sets of clinical data obtained during oral glucose tolerance test and isoglycemic intravenous glucose infusion test from both type 2 diabetic and healthy subjects to estimate the model parameters and to validate the model results. The estimation of model parameters is accomplished through solving a nonlinear optimization problem. The results show acceptable precision of the estimated model parameters and demonstrate the capability of the model in accurate prediction of the body response during the clinical studies.

  18. Impact of PTBP1 rs11085226 on glucose-stimulated insulin release in adult Danes

    DEFF Research Database (Denmark)

    Hansen, Tue Haldor; Vestergaard, Henrik; Jørgensen, Torben

    2015-01-01

    ,641 glucose tolerant controls, respectively. Quantitative trait analyses were performed in up to 13,605 individuals subjected to an OGTT or blood samples obtained after an overnight fast, as well as in 596 individuals subjected to an IVGTT. Results: Analyses of fasting and OGTT-derived quantitative traits did.......024; P=0.01) assuming a dominant model of inheritance, but failed to replicate a previously reported association with area under the curve (AUC) for insulin. Case control analysis did not show an association of the PTBP1 rs11085226 variant with type 2 diabetes. Conclusions: Despite failure to replicate......Background: The variant rs11085226 (G) within the gene encoding polypyrimidine tract binding protein 1 (PTBP1) was reported to associate with reduced insulin release determined by an oral glucose tolerance test (OGTT) as well as an intravenous glucose tolerance test (IVGTT). The aim of the present...

  19. The dipeptidyl peptidase-4 inhibitor vildagliptin improves beta-cell function and insulin sensitivity in subjects with impaired fasting glucose

    DEFF Research Database (Denmark)

    Utzschneider, Kristina M; Tong, Jenny; Montgomery, Brenda

    2007-01-01

    OBJECTIVE: To evaluate the effect of treatment with the dipeptidyl peptidase (DPP)-4 inhibitor vildagliptin on insulin sensitivity and beta-cell function in subjects with impaired fasting glucose (IFG). RESEARCH DESIGN AND METHODS: A total of 22 subjects with IFG (11 female and 11 male, mean +/- SD...... age 59.6 +/- 11.5 years) were treated orally with 100 mg vildagliptin once daily in a single-blind study. Subjects received placebo for 2 weeks (run-in) followed by vildagliptin for 6 weeks (treatment) and then placebo for 2 weeks (washout). A frequently sampled intravenous glucose tolerance test....... RESULTS: Fasting plasma glucose did not change after 6 weeks of vildagliptin treatment. With treatment, mean +/- SEM AIR(g) increased from 224 +/- 44 to 286 +/- 52 pmol/l (P

  20. Experience-dependent escalation of glucose drinking and the development of glucose preference over fructose - association with glucose entry into the brain.

    Science.gov (United States)

    Wakabayashi, Ken T; Spekterman, Laurence; Kiyatkin, Eugene A

    2016-06-01

    Glucose, a primary metabolic substrate for cellular activity, must be delivered to the brain for normal neural functions. Glucose is also a unique reinforcer; in addition to its rewarding sensory properties and metabolic effects, which all natural sugars have, glucose crosses the blood-brain barrier and acts on glucoreceptors expressed on multiple brain cells. To clarify the role of this direct glucose action in the brain, we compared the neural and behavioural effects of glucose with those induced by fructose, a sweeter yet metabolically equivalent sugar. First, by using enzyme-based biosensors in freely moving rats, we confirmed that glucose rapidly increased in the nucleus accumbens in a dose-dependent manner after its intravenous delivery. In contrast, fructose induced a minimal response only after a large-dose injection. Second, we showed that naive rats during unrestricted access consumed larger volumes of glucose than fructose solution; the difference appeared with a definite latency during the initial exposure and strongly increased during subsequent tests. When rats with equal sugar experience were presented with either glucose or fructose in alternating order, the consumption of both substances was initially equal, but only the consumption of glucose increased during subsequent sessions. Finally, rats with equal glucose-fructose experience developed a strong preference for glucose over fructose during a two-bottle choice procedure; the effect appeared with a definite latency during the initial test and greatly amplified during subsequent tests. Our results suggest that direct entry of glucose in the brain and its subsequent effects on brain cells could be critical for the experience-dependent escalation of glucose consumption and the development of glucose preference over fructose. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  1. Intravenous glucose intake independently related to intensive care unit and hospital mortality : an argument for glucose toxicity in critically ill patients

    NARCIS (Netherlands)

    van der Voort, PHJ; Feenstra, RA; Bakker, AJ; de Heide, L; Boerma, EC; van der Horst, ICC

    Objective It is assumed that the toxic effects of glucose play a role in the outcome of critically ill patients. We studied the impact of the amount of infused glucose as a determinant of mortality. Design A retrospective cohort study design was used as blood glucose levels in critically ill

  2. Mathematical modeling of the glucose-insulin system

    DEFF Research Database (Denmark)

    Palumbo, Pasquale; Ditlevsen, Susanne; Bertuzzi, Alessandro

    2013-01-01

    of pancreatic insulin production, with a oarser/finer level of detail ranging over cellular and subcellular scales, to short-term organ/tissue models accounting for the intra-venous and the oral glucose tolerance tests as well as for the euglycemic hyperinsulinemic clamp, to total-body, long-term diabetes...

  3. The Evaluation of a Low-Cost Colorimeter for Glucose Detection in Salivary Samples.

    Science.gov (United States)

    Dominguez, Rocio B; Orozco, Miguel A; Chávez, Giovanny; Márquez-Lucero, Alfredo

    2017-11-01

    Given the limited access to healthcare resources, low-income settings require the development of affordable technology. Here we present the design and evaluation of a low-cost colorimeter applied to the non-invasive monitoring of Diabetes Mellitus through the detection of glucose in salival fluid. Samples were processed by the glucose oxidase-peroxidase enzymatic system and analyzed with the development equipment. A light emission diode of 532.5 nm was used as an excitation source and a RGB module was used as a receptor. A calibration curve to quantify the concentration of salivary glucose (0 to 18 mg/dL) was carried out by relating the RGB components registered with glucose concentrations, achieving a limit of detection of 0.17 mg/dL with a CV of 5% (n = 3). Salivary samples of diabetic and healthy volunteers were processed with the equipment showing an average concentration of 1.5519 ± 0.4511 mg/dL for the first and 4.0479 ± 1.6103 mg/dL for the last, allowing a discrimination between both groups. Results were validated against a UV-Vis-NIR spectrophotometer with a correspondence of R² of 0.98194 between both instruments. Results suggest the potential application of the developed device to the sensitive detection of relevant analytes with a low-cost, user-friendly, low-power and portable instrumentation.

  4. The acute glucose lowering effect of specific GPR120 activation in mice is mainly driven by glucagon-like peptide 1.

    Directory of Open Access Journals (Sweden)

    Linda Sundström

    Full Text Available The mechanism behind the glucose lowering effect occurring after specific activation of GPR120 is not completely understood. In this study, a potent and selective GPR120 agonist was developed and its pharmacological properties were compared with the previously described GPR120 agonist Metabolex-36. Effects of both compounds on signaling pathways and GLP-1 secretion were investigated in vitro. The acute glucose lowering effect was studied in lean wild-type and GPR120 null mice following oral or intravenous glucose tolerance tests. In vitro, in GPR120 overexpressing cells, both agonists signaled through Gαq, Gαs and the β-arrestin pathway. However, in mouse islets the signaling pathway was different since the agonists reduced cAMP production. The GPR120 agonists stimulated GLP-1 secretion both in vitro in STC-1 cells and in vivo following oral administration. In vivo GPR120 activation induced significant glucose lowering and increased insulin secretion after intravenous glucose administration in lean mice, while the agonists had no effect in GPR120 null mice. Exendin 9-39, a GLP-1 receptor antagonist, abolished the GPR120 induced effects on glucose and insulin following an intravenous glucose challenge. In conclusion, GLP-1 secretion is an important mechanism behind the acute glucose lowering effect following specific GPR120 activation.

  5. Short-term glucagon stimulation test of C-peptide effect on glucose utilization in patients with type 1 diabetes mellitus.

    Science.gov (United States)

    Mojto, Viliam; Rausova, Zuzana; Chrenova, Jana; Dedik, Ladislav

    2015-12-01

    This work aimed to evaluate the use of a four-point glucagon stimulation test of C-peptide effect on glucose utilization in type 1 diabetic patients using a new mathematical model. A group of 32 type 1 diabetic patients and a group of 10 healthy control subjects underwent a four-point glucagon stimulation test with blood sampling at 0, 6, 15 and 30 min after 1 mg glucagon bolus intravenous administration. Pharmacokinetic and pharmacokinetic/pharmacodynamic models of C-peptide effect on glucose utilization versus area under curve (AUC) were used. A two-sample t test and ANOVA with Bonferroni correction were used to test the significance of differences between parameters. A significant difference between control and patient groups regarding the coefficient of whole-body glucose utilization and AUC C-peptide/AUC glucose ratio (p ≪ 0.001 and p = 0.002, respectively) was observed. The high correlation (r = 0.97) between modeled coefficient of whole-body glucose utilization and numerically calculated AUC C-peptide/AUC glucose ratio related to entire cohort indicated the stability of used method. The short-term four-point glucagon stimulation test allows the numerically calculated AUC C-peptide/AUC glucose ratio and/or the coefficient of whole-body glucose utilization calculated from model to be used to diagnostically identify type 1 diabetic patients.

  6. Glucose turnover, gluconeogenesis from glycerol, and estimation of net glucose cycling in cancer patients

    International Nuclear Information System (INIS)

    Lundholm, K.; Edstroem, S.; Karlberg, I.; Ekman, L.; Schersten, T.

    1982-01-01

    A double isotope method was used in patients with progressive malignancy and in control patients to measure: glucose turnover, conversion rate of carbon skeleton of glycerol into glucose, and the interorgan cycling of glucose carbons (Cori-cycle plus alanine-glucose cycle). [U- 14 C]glycerol and [6- 3 H]glucose were given intravenously as a single dose injection. The time course of the specific radioactivities of [6- 3 H] and [U- 14 C]glucose was followed in blood. The pool size and the turnover rate of glucose were increased in the cancer group as compared with the control patients. The net recycling of glucose carbons was not increased in the cancer group, despite the increased turnover of glucose. The alterations in the metabolism of glucose did not correlate with the plasma levels of insulin or thyroid hormones (T4, T3, rT3) neither in the entire cancer group nor in those cancer patients who were repeatedly investigated at different intervals of time. The turnover rate of glucose in the cancer patients correlated inversely to their body weight index. The gluconeogenesis rate, given as the fractional conversion rate of the injected radioactive dose of [ 14 C]glycerol, or as mol glucose . kg body weight-1 . day-1, was increased in the cancer group, but still contributed only 3% of the glucose turnover rate in both cancer and control patients. We conclude that an increased gluconeogenesis from glycerol is not significant in terms of energy expenditure in patients with progressive malignancy, as has previously been concluded for the gluconeogenesis from alanine. It seems that increased turnover of glucose may contribute to inappropriately high energy expenditure in cancer patients

  7. Moderate glucose supply reduces hemolysis during systemic inflammation

    Directory of Open Access Journals (Sweden)

    Jägers J

    2018-03-01

    Full Text Available Johannes Jägers,1 Stephan Brauckmann,2 Michael Kirsch,1 Katharina Effenberger-Neidnicht1,3 1Institute of Physiological Chemistry, University Hospital Essen, Essen, Germany; 2Clinic for Anesthesiology and Intensive Care, University Hospital Essen, Essen, Germany; 3Institute of Physiological Chemistry, University Hospital Essen, Essen, Germany Background: Systemic inflammation alters energy metabolism. A sufficient glucose level, however, is most important for erythrocytes, since erythrocytes rely on glucose as sole source of energy. Damage to erythrocytes leads to hemolysis. Both disorders of glucose metabolism and hemolysis are associated with an increased risk of death. The objective of the study was to investigate the impact of intravenous glucose on hemolysis during systemic inflammation.Materials and methods: Systemic inflammation was accomplished in male Wistar rats by continuous lipopolysaccharide (LPS infusion (1 mg LPS/kg and h, 300 min. Sham control group rats received Ringer’s solution. Glucose was supplied moderately (70 mg glucose/kg and h or excessively (210 mg glucose/kg and h during systemic inflammation. Vital parameters (eg, systemic blood pressure as well as blood and plasma parameters (eg, concentrations of glucose, lactate and cell-free hemoglobin, and activity of lactate dehydrogenase were measured hourly. Clot formation was analyzed by thromboelastometry.Results: Continuous infusion of LPS led to a so-called post-aggression syndrome with disturbed electrolyte homeostasis (hypocalcemia, hyperkalemia, and hypernatremia, changes in hemodynamics (tachycardia and hypertension, and a catabolic metabolism (early hyperglycemia, late hypoglycemia, and lactate formation. It induced severe tissue injury (significant increases in plasma concentrations of transaminases and lactate dehydrogenase, alterations in blood coagulation (disturbed clot formation, and massive hemolysis. Both moderate and excessive glucose supply reduced LPS

  8. AICAR administration affects glucose metabolism by upregulating the novel glucose transporter, GLUT8, in equine skeletal muscle.

    Science.gov (United States)

    de Laat, M A; Robinson, M A; Gruntmeir, K J; Liu, Y; Soma, L R; Lacombe, V A

    2015-09-01

    Equine metabolic syndrome is characterized by obesity and insulin resistance (IR). Currently, there is no effective pharmacological treatment for this insidious disease. Glucose uptake is mediated by a family of glucose transporters (GLUT), and is regulated by insulin-dependent and -independent pathways, including 5-AMP-activated protein kinase (AMPK). Importantly, the activation of AMPK, by 5-aminoimidazole-4-carboxamide-1-D-ribofuranoside (AICAR) stimulates glucose uptake in both healthy and diabetic humans. However, whether AICAR promotes glucose uptake in horses has not been established. It is hypothesized that AICAR administration would enhance glucose transport in equine skeletal muscle through AMPK activation. In this study, the effect of an intravenous AICAR infusion on blood glucose and insulin concentrations, as well as on GLUT expression and AMPK activation in equine skeletal muscle (quantified by Western blotting) was examined. Upon administration, plasma AICAR rapidly reached peak concentration. Treatment with AICAR resulted in a decrease (P change in lactate concentration. The ratio of phosphorylated to total AMPK was increased (P managing IR requires investigation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. High heritability and genetic correlation of intravenous glucose- and tolbutamide-induced insulin secretion among non-diabetic family members of type 2 diabetic patients

    DEFF Research Database (Denmark)

    Gjesing, Anette Marianne Prior; Hornbak, Malene; Allin, Kristine H.

    2014-01-01

    ∈±∈SE: 0.49∈±∈0.14) and beta cell responsiveness to glucose (h 2∈±∈SE: 0.66∈±∈0.12). Additionally, strong genetic correlations were found between measures of beta cell response after glucose and tolbutamide stimulation, with correlation coefficients ranging from 0.77 to 0.88. Furthermore, we identified......Aims/hypothesis: The aim of this study was to estimate the heritability of quantitative measures of glucose regulation obtained from a tolbutamide-modified frequently sampled IVGTT (t-FSIGT) and to correlate the heritability of the glucose-stimulated beta cell response to the tolbutamide...... after tolbutamide (DIT), insulin sensitivity (SI), glucose effectiveness (SG) and beta cell responsiveness to glucose were calculated. A polygenic variance component model was used to estimate heritability, genetic correlations and associations. Results: We found high heritabilities for acute insulin...

  10. Influence of Partial Pressure of Oxygen in Blood Samples on Measurement Performance in Glucose-Oxidase-Based Systems for Self-Monitoring of Blood Glucose

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-01-01

    Background Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Methods Aliquots of 20 venous samples were adjusted to the following pO2 values: pO2 ~70 mmHg, which is considered to be similar to pO2 in capillary blood samples, and the mean BG result at pO2 pO2 pO2 ≥150 mmHg. For both pO2 levels, relative differences of all tested GOx systems were significant (p pO2 values pO2 variations lead to clinically relevant BG measurement deviations in GOx systems, even in GOx systems that are not labeled as being oxygen sensitive. PMID:24351177

  11. The Various Forms of Insulin Secretion Response to the Intravenous and Oral Administration of Glucose in Non-Insulin-Dependent Diabetes Mellitus; Les Differentes Modalites de Reponse Insulino-Secretrice Lors de Charges Veineuse et Orale en Glucose dans le Diabete Sucre Non Insulino-Dependant

    Energy Technology Data Exchange (ETDEWEB)

    Mirouze, J.; Orsetti, A.; Lapinski, H. [Clinique des Maladies Metaboliques et Endocriniennes, Hopital St-Eloi, Montpellier (France)

    1970-02-15

    On the basis of 68 observations on advanced diabetes mellitus (20 cases), latent diabetes with obesity (12 cases), chemical diabetes with subjective symptoms (26 cases) and 10 observations of obesity without diabetes, the authors have analysed the various forms of insulin secretion response to the intravenous and oral administration of glucose. The response appeared to be totally withdrawn in advanced diabetes mellitus although the patients were still capable of responding to stimulation with glucagon. In the two other forms of diabetes described, the response to stimulation by intravenous administration was less marked than in normal subjects. With oral administration, on the other hand, the response was greater, although the insulin secreted in this case appeared ineffective in cases of obesity but effective in conditions without obesity due to the hypoglycaemic effect. (author) [French] A l'aide de 68 observations de diabete sucre evolue (20 cas), latent avec obesite (12 cas), chimique avec malaises (26 cas) et de 10 observations d'obesite sans diabete, les auteurs analysent les differentes modalites de riposte insulino- secretrice lors des charges en glucose, veineuse et orale. La riposte s'avere totalement effondree dans le diabete evolue, mais susceptible de repondre encore a la stimulation par le glucagon. Dans les deux autres formes de diabete decrites, la stimulation par charge veineuse est reduite par rapport au sujet normal alors qu'elle est majoree apres charge orale mais l'insuline ainsi secretee parait inefficace dans l'obesite et efficace puisque hypoglycemiante lors de malaises sans obesite. (author)

  12. Survivability of Existing Peripheral Intravenous Access Following Blood Sampling in a Pediatric Population.

    Science.gov (United States)

    O'Neil, Sheree W; Friesen, Mary Ann; Stanger, Debra; Trickey, Amber Williams

    2018-03-07

    Although pediatric patients report venipuncture as their most feared experience during hospitalization, blood sampling from peripheral intravenous accesses (PIVs) is not standard of care. Blood sampling from PIVs has long been considered by healthcare personnel to harm the access. In an effort to minimize painful procedures, pediatric nursing staff conducted a prospective, observational study to determine if blood sampling using existing PIVs resulted in the loss of the access. The ability to obtain the sample from the PIV was measured along with patient and PIV characteristics. Specimen collection using 100 existing PIVs was attempted on pediatric inpatients. Each PIV was observed for functionality, infiltration, occlusion, and dislodgement following collection and again in 4h. Frequencies of PIV loss and successful blood sampling were calculated. Patient age, PIV gauge, access site, and PIV age were evaluated for associations with successful sampling using chi-square tests, Fisher's exact tests, and logistic regression. PIV survivability was reported at 99%. The ability to obtain a complete specimen was reported at 76% and found to be significantly related to PIV age and site. Size of PIV and patient's age were not significantly related to successful sampling. Encouraging rates of PIV survivability and collectability suggest blood sampling from PIVs to be a valuable technique to minimize painful and distressful procedures. Nursing practice was changed in this pediatric department. Patients and families are saved the pain and distress of venipuncture. Nurses reported saving time and personal distress by avoiding the venipuncture procedure. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Pathophysiological Characteristics Underlying Different Glucose Response Curves

    DEFF Research Database (Denmark)

    Hulman, Adam; Witte, Daniel R; Vistisen, Dorte

    2018-01-01

    different glucose curve patterns and studied their stability and reproducibility over 3 years of follow-up. RESEARCH DESIGN AND METHODS: We analyzed data from participants without diabetes from the observational cohort from the European Group for the Study of Insulin Resistance: Relationship between Insulin...... and secretion. The glucose patterns identified at follow-up were similar to those at baseline, suggesting that the latent class method is robust. We integrated our classification model into an easy-to-use online application that facilitates the assessment of glucose curve patterns for other studies. CONCLUSIONS...... Sensitivity and Cardiovascular Disease study; participants had a five-time point OGTT at baseline (n = 1,443) and after 3 years (n = 1,045). Measures of insulin sensitivity and secretion were assessed at baseline with a euglycemic-hyperinsulinemic clamp and intravenous glucose tolerance test. Heterogeneous...

  14. [A comparison of post-surgical plasma glucose levels in patients on fluids with different glucose concentrations].

    Science.gov (United States)

    Martínez Carapeto, Isabel; López Castilla, José Domingo; Fresneda Gutiérrez, Reyes

    2017-11-11

    To compare plasma glucose levels and incidence of hyperglycaemia in the post-operative period after general surgery using fluids with different glucose. A randomised, open-label, non-blind, clinical trial was conducted on patients admitted to Paediatric Intensive Care Unit after elective surgery. The inclusion criteria were from 6 months to 14 years of age, with a weight greater than 6kg, onset glucose level >60mg/dL, and a signed informed consent, with no oral intake and maintenance intravenous fluid therapy using fluids with 3.3% or 5% glucose. Plasma glucose levels were measured before surgery, on admission, and 8, 24, and 48h, with the mean glucose levels and incidence of hyperglycaemia (glucose level >150mg/dL) in both groups being compared. A total of 60 patients received glucose/saline 1/3 (51mEq/L sodium and 33g/L glucose), and 70 glucose/saline 5/0.9% (154mEq/L sodium and 50g/L glucose). Mean glucose levels were higher in the group receiving glucose 5%, with no statistical difference. There was no significant difference in the incidence of hyperglycaemia; 8h: 26% in the 3.3% group vs. 21.3% in the 5% group (P=.63); 24h: 20% vs. 22.7% (P=.8); and 48h: 19% vs. 23.1% (P=.78). The use of fluids with 3.3% glucose in the post-operative period of general surgery maintains mean glucose levels in a similar range to that of patients receiving fluids with 5% glucose, with no difference in the incidence of hyperglycaemia. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  15. Stimulation of gluconeogenesis by intravenous lipids in preterm infants: response depends on fatty acid profile

    NARCIS (Netherlands)

    van Kempen, Anne A. M. W.; van der Crabben, Saskia N.; Ackermans, Mariëtte T.; Endert, Erik; Kok, Joke H.; Sauerwein, Hans P.

    2006-01-01

    In preterm infants, both hypo- and hyperglycemia are a frequent problem. Intravenous lipids can affect glucose metabolism by stimulation of gluconeogenesis by providing glycerol, which is a gluconeogenic precursor, and/or free fatty acids (FFA), which are stimulants of the rate of gluconeogenesis.

  16. Defective glucose and lipid metabolism in human immunodeficiency virus-infected patients with lipodystrophy involve liver, muscle tissue and pancreatic beta-cells

    DEFF Research Database (Denmark)

    Haugaard, Steen B; Andersen, Ove; Dela, Flemming

    2005-01-01

    .01. Disposition index (i.e. first-phase insulin response to intravenous glucose multiplied by incremental glucose disposal) was reduced by 46% (P = 0.05) in LIPO compared with the combined groups of NONLIPO and NAIVE, indicating an impaired adaptation of beta-cell function to insulin resistance in LIPO...... of glucose metabolism, lipid metabolism and beta-cell function in lipodystrophic HIV-infected patients. METHODS: [3-3H]glucose was applied during euglycaemic hyperinsulinaemic clamps in association with indirect calorimetry in 43 normoglycaemic HIV-infected patients (18 lipodystrophic patients on HAART (LIPO......), 18 patients without lipodystrophy on HAART (NONLIPO) and seven patients who were naive to antiretroviral therapy (NAIVE) respectively). beta-cell function was evaluated by an intravenous glucose tolerance test. RESULTS: Compared with NONLIPO and NAIVE separately, LIPO displayed markedly reduced ratio...

  17. Normalization of fasting glycaemia by intravenous GLP-1 ([7-36 amide] or [7-37]) in type 2 diabetic patients

    DEFF Research Database (Denmark)

    Nauck, M A; Weber, I; Bach, I

    1998-01-01

    (glucose-oxidase), insulin and C-peptide (ELISA) was measured during infusion and for 4 h thereafter. Indirect calorimetry was performed. Fasting hyperglycaemia was 11.7+/-0.9 [7-36 amide] and 11.3+/-0.9 mmol l(-1) [7-37]. GLP-1 infusions stimulated insulin secretion approximately 3-fold (insulin peak 168......Intravenous GLP-1 [7-36 amide] can normalize fasting hyperglycaemia in Type 2 diabetic patients. Whether GLP-1 [7-37] has similar effects and how quickly plasma glucose concentrations revert to hyperglycaemia after stopping GLP-1 is not known. Therefore, 8 patients with Type 2 diabetes (5 female, 3...... male; 65+/-6 years; BMI 34.3+/-7.9 kg m(-2); HbA1c 9.6+/-1.2%; treatment with diet alone (n=2), sulphonylurea (n=5), metformin (n=1)) were examined twice in randomized order. GLP-1 [7-36 amide] or [7-37] (1 pmol kg(-1)min(-1) were infused intravenously over 4 h in fasted subjects. Plasma glucose...

  18. Validation of different measures of insulin sensitivity of glucose metabolism in dairy cows using the hyperinsulinemic euglycemic clamp test as the gold standard.

    Science.gov (United States)

    De Koster, J; Hostens, M; Hermans, K; Van den Broeck, W; Opsomer, G

    2016-10-01

    The aim of the present research was to compare different measures of insulin sensitivity in dairy cows at the end of the dry period. To do so, 10 clinically healthy dairy cows with a varying body condition score were selected. By performing hyperinsulinemic euglycemic clamp (HEC) tests, we previously demonstrated a negative association between the insulin sensitivity and insulin responsiveness of glucose metabolism and the body condition score of these animals. In the same animals, other measures of insulin sensitivity were determined and the correlation with the HEC test, which is considered as the gold standard, was calculated. Measures derived from the intravenous glucose tolerance test (IVGTT) are based on the disappearance of glucose after an intravenous glucose bolus. Glucose concentrations during the IVGTT were used to calculate the area under the curve of glucose and the clearance rate of glucose. In addition, glucose and insulin data from the IVGTT were fitted in the minimal model to derive the insulin sensitivity parameter, Si. Based on blood samples taken before the start of the IVGTT, basal concentrations of glucose, insulin, NEFA, and β-hydroxybutyrate were determined and used to calculate surrogate indices for insulin sensitivity, such as the homeostasis model of insulin resistance, the quantitative insulin sensitivity check index, the revised quantitative insulin sensitivity check index and the revised quantitative insulin sensitivity check index including β-hydroxybutyrate. Correlation analysis revealed no association between the results obtained by the HEC test and any of the surrogate indices for insulin sensitivity. For the measures derived from the IVGTT, the area under the curve for the first 60 min of the test and the Si derived from the minimal model demonstrated good correlation with the gold standard. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Discrete Blood Glucose Control in Diabetic Göttingen Minipigs

    Directory of Open Access Journals (Sweden)

    Berno J.E. Misgeld

    2016-07-01

    Full Text Available Despite continuous research effort, patients with type 1 diabetes mellitus (T1D experience difficulties in daily adjustments of their blood glucose concentrations. New technological developments in the form of implanted intravenous infusion pumps and continuous blood glucose sensors might alleviate obstacles for the automatic adjustment of blood glucose concentration. These obstacles consist, for example, of large time-delays and insulin storage effects for the subcutaneous/interstitial route. Towards the goal of an artificial pancreas, we present a novel feedback controller approach that combines classical loop-shaping techniques with gain-scheduling and modern H ∞ -robust control approaches. A disturbance rejection design is proposed in discrete frequency domain based on the detailed model of the diabetic Göttingen minipig. The model is trimmed and linearised over a large operating range of blood glucose concentrations and insulin sensitivity values. Controller parameters are determined for each of these operating points. A discrete H ∞ loop-shaping compensator is designed to increase robustness of the artificial pancreas against general coprime factor uncertainty. The gain scheduled controller uses subcutaneous insulin injection as a control input and determines the controller input error from intravenous blood glucose concentration measurements, where parameter scheduling is achieved by an estimator of the insulin sensitivity parameter. Thus, only one controller stabilises a family of animal models. The controller is validated in silico with a total number of five Göttingen Minipig models, which were previously obtained by experimental identification procedures. Its performance is compared with an experimentally tested switching PI-controller.

  20. Influence of gastrointestinal factors on glucose metabolism in patients with cirrhosis

    DEFF Research Database (Denmark)

    Junker, Anders E; Gluud, Lise L; Holst, Jens Juul

    2015-01-01

    BACKGROUND AND AIMS: The impaired glucose tolerance in cirrhosis is poorly understood. We evaluated the influence of gastrointestinal-mediated glucose disposal and incretin effect in patients with cirrhosis. METHODS: Non-diabetic patients with Child Pugh A or B cirrhosis (n = 10) and matched...... of intravenous glucose in patients with cirrhosis compared to 24 ± 10 g in healthy controls (P = 0.003). The gastrointestinal-mediated glucose disposal was markedly lower in patients with cirrhosis (30 ± 23 vs. 52 ± 20%; P = 0.003). Despite higher levels of the incretin hormones glucagon-like peptide-1 (GLP-1......) and glucose-dependent insulinotropic peptide (GIP) patients with cirrhosis had reduced incretin effect (35 ± 44 vs. 55 ± 30%; P = 0.008). CONCLUSIONS: Impaired gastrointestinal-mediated glucose disposal and reduced incretin effect may contribute to the glucose intolerance seen in patients with cirrhosis....

  1. Glucose effectiveness is a critical pathogenic factor leading to glucose intolerance and type 2 diabetes: An ignored hypothesis.

    Science.gov (United States)

    Alford, F P; Henriksen, J E; Rantzau, C; Beck-Nielsen, H

    2018-02-16

    Although the ability of glucose to mediate its own in vivo metabolism is long documented, the quantitative measurement of whole body glucose-mediated glucose disposal at basal insulin levels (glucose effectiveness [GE]), followed the introduction of the Minimal Model intravenous glucose tolerance test technique. A literature review, combined with our own studies, of the role of GE in glucose metabolism in normal and "at risk" individuals, was undertaken to determine GE's contribution to glucose homeostasis. GE accounts for ~45% to 65% of glucose disposal in man. A negative association between GE and insulin meditated glucose disposal (Si), is present in normal subjects without a family history of type 2 diabetes mellitus but is absent in normoglycaemic "at risk" relatives with a positive family history of diabetes mellitus. Intracellular GE disposal is mediated by mass action of glucose through the skeletal muscle membrane via facilitated Glut 4 transporters. However, GE is frequently forgotten as a significant contributor to the development of glucose intolerance in "at risk" individuals. Only limited studies have examined the role of a lower GE in such normoglycemic subjects with preexisting mild insulin resistance and β-cell dysfunction. These studies demonstrate that in "at risk" individuals, an initial low GE is a key contributor and predictor of future glucose intolerance, whereas an initial raised GE is protective against future glucose intolerance. In "at risk" individuals, a low GE and genetically determined vulnerable β-cell function are more critical determinants of future glucose intolerance than their preexisting insulin-resistant state. Copyright © 2018 John Wiley & Sons, Ltd.

  2. Correlation of Salivary Glucose Level with Blood Glucose Level in Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Arati S. Panchbhai

    2012-07-01

    Full Text Available Objectives: There is alarming rise in number of people with diabetes mellitus over these years. If glucose in saliva is linked to glucose in blood it can be used to detect diabetes mellitus at an early stage. The present study is undertaken with the aim to assess the correlation of salivary glucose level with blood glucose level in people with diabetes mellitus. Material and Methods: For investigations, 2 sets of samples of people with diabetes and the age and sex matched non-diabetic subjects were recruited. The salivary glucose was analyzed in unstimulated whole saliva samples using glucose oxidase method. Pearson’s correlation coefficient test was applied to assess the correlation between salivary glucose level and blood glucose level. Results: The significant (P < 0.05 positive correlation of salivary glucose level and fasting blood glucose level was observed in people with uncontrolled diabetes in both the sets of samples.Conclusions: Although study suggests some potential for saliva as a marker in monitoring of diabetes mellitus, there are many aspects that need clarification before we reach to a conclusion.

  3. Blood glucose level reconstruction as a function of transcapillary glucose transport.

    Science.gov (United States)

    Koutny, Tomas

    2014-10-01

    A diabetic patient occasionally undergoes a detailed monitoring of their glucose levels. Over the course of a few days, a monitoring system provides a detailed track of their interstitial fluid glucose levels measured in their subcutaneous tissue. A discrepancy in the blood and interstitial fluid glucose levels is unimportant because the blood glucose levels are not measured continuously. Approximately five blood glucose level samples are taken per day, and the interstitial fluid glucose level is usually measured every 5min. An increased frequency of blood glucose level sampling would cause discomfort for the patient; thus, there is a need for methods to estimate blood glucose levels from the glucose levels measured in subcutaneous tissue. The Steil-Rebrin model is widely used to describe the relationship between blood and interstitial fluid glucose dynamics. However, we measured glucose level patterns for which the Steil-Rebrin model does not hold. Therefore, we based our research on a different model that relates present blood and interstitial fluid glucose levels to future interstitial fluid glucose levels. Using this model, we derived an improved model for calculating blood glucose levels. In the experiments conducted, this model outperformed the Steil-Rebrin model while introducing no additional requirements for glucose sample collection. In subcutaneous tissue, 26.71% of the calculated blood glucose levels had absolute values of relative differences from smoothed measured blood glucose levels less than or equal to 5% using the Steil-Rebrin model. However, the same difference interval was encountered in 63.01% of the calculated blood glucose levels using the proposed model. In addition, 79.45% of the levels calculated with the Steil-Rebrin model compared with 95.21% of the levels calculated with the proposed model had 20% difference intervals. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Glucose kinetics in infants of diabetic mothers

    International Nuclear Information System (INIS)

    Cowett, R.M.; Susa, J.B.; Giletti, B.; Oh, W.; Schwartz, R.

    1983-01-01

    Glucose kinetic studies were performed to define the glucose turnover rate with 78% enriched D-[U-13C] glucose by the prime constant infusion technique at less than or equal to 6 hours of age in nine infants of diabetic mothers (four insulin-dependent and five chemical diabetic patients) at term. Five normal infants were studied as control subjects. All infants received 0.9% saline intravenously during the study with the tracer. Fasting plasma glucose, insulin, and glucose13/12C ratios were measured during the steady state, and the glucose turnover rate was derived. The average plasma glucose concentration was similar during the steady state in the infants of the diabetic mothers and in the control infants, and the glucose turnover rate was not significantly different among the groups: 2.3 +/- 0.6 mg . kg-1 min-1 in infants of insulin-dependent diabetic patients; 2.4 +/- 0.4 mg . kg-1 min-1 in infants of chemical diabetic patients; and 3.2 +/- 0.3 mg . kg-1 min-1 in the control subjects. Good control of maternal diabetes evidenced by the normal maternal hemoglobin A1c and plasma glucose concentration at delivery and cord plasma glucose concentration resulted in glucose kinetic values in the infants of diabetic mothers that were indistinguishable from those of control subjects. The data further support the importance of good control of the diabetic state in the pregnant woman to minimize or prevent neonatal hypoglycemia

  5. [The association between early blood glucose fluctuation and prognosis in critically ill patients].

    Science.gov (United States)

    Tang, Jian; Gu, Qin

    2012-01-01

    To investigate the association between early blood glucose level fluctuation and prognosis of critically ill patients. A retrospective study involving 95 critically ill patients in intensive care unit (ICU) was conducted. According to the 28-day outcome after admission to ICU, the patients were divided into nonsurvivors (43 cases) and survivors (52 cases), and the blood glucose level in them was monitored in the first 72 hours. Blood glucose concentration at admission (BGadm), mean blood glucose level (MBG), hyperglycemia index (HGI), glycemic lability index (GLI), incidence of hypoglycemia and total dosage of intravenous insulin for each patient were compared. The index as an independent risk factor of mortality was determined by multivariate logistic regression analysis and the predictor value by comparing the area under the receiver operating characteristic curve (ROC curve, AUC) of each index. The BGadm (mmol/L), MBG (mmol/L), HGI and the incidence of hypoglycemia showed no significant differences between nonsurvivors and survivors [BGadm: 9.87 ± 4.48 vs. 9.26 ± 3.07, MBG: 8.59 ± 1.23 vs. 8.47 ± 1.01, HGI(6.0): 2.45 ± 0.94 vs. 1.68 ± 1.05, HGI(8.3): 0.84 ± 0.70 vs. 0.68 ± 0.51, the incidence of hypoglycemia: 9.30% vs. 5.77%, all P > 0.05], but acute physiology and chronic health evaluation II (APACHE II ) score, GLI and the total dosage of intravenous insulin (U) were significantly higher in nonsurvivors than survivors [APACHE II score: 23 ± 6 vs. 19 ± 6, GLI: 56.96 (65.43) vs. 23.87 (41.62), the total dosage of intravenous insulin: 65.5 (130.5) vs. 12.5 (90.0), all P curve was plotted, the AUC of APACHE II score and GLI was respectively 0.69 and 0.71, and there was no significant difference (P > 0.05). Early fluctuation of blood glucose is a significant independent risk factor of mortality in critically ill patients. Control the early fluctuation of blood glucose concentration might improve the patients' outcome.

  6. Preserved glucagon-like peptide-1 responses to oral glucose, but reduced incretin effect, insulin secretion and sensitivity in young Asians with type 2 diabetes mellitus

    DEFF Research Database (Denmark)

    Yeow, Toh Peng; Pacini, Giovanni; Tura, Andrea

    2017-01-01

    are scarce. We examined the insulin resistance, β-cell function (BC), glucagon-like peptide (GLP)-1 hormone and incretin effect in Asian YT2DM. RESEARCH DESIGN AND METHODS: This case-control study recruited 25 Asian YT2DM and 15 healthy controls, matched for gender, ethnicity and body mass index. Serum......OBJECTIVE: Youth onset type 2 diabetes mellitus (YT2DM) is a globally rising phenomenon with substantial Asians representation. The understanding of its pathophysiology is derived largely from studies in the obese African-American and Caucasian populations, while studies on incretin effect...... glucose, insulin, C peptide and GLP-1 were sampled during 2-hour oral glucose tolerance tests (OGTTs) and 1-hour intravenous glucose tolerance tests (IVGTTs). Insulin sensitivity was derived from the Quantitative Insulin Sensitivity Check Index (QUICKI), Oral Glucose Insulin Sensitivity Index (OGIS...

  7. Secretion of incretin hormones (GIP and GLP-1) and incretin effect after oral glucose in first-degree relatives of patients with type 2 diabetes

    DEFF Research Database (Denmark)

    Nauck, Michael A; El-Ouaghlidi, Andrea; Gabrys, Bartholomäus

    2004-01-01

    ) and an "isoglycaemic" intravenous glucose infusion. Blood was drawn over 240 min for plasma glucose (glucose oxidase), insulin, C-peptide, GIP and glucagon-like peptide 1 (GLP-1; specific immunoassays). RESULTS: The pattern of glucose concentrations could precisely be copied by the intravenous glucose infusion (p=0......AIMS/HYPOTHESIS: Since insulin secretion in response to exogenous gastric inhibitory polypeptide (GIP) is diminished not only in patients with type 2 diabetes, but also in their normal glucose-tolerant first-degree relatives, it was the aim to investigate the integrity of the entero-insular axis...... in such subjects. METHODS: Sixteen first-degree relatives of patients with type 2 diabetes (4 male, 12 female, age 50+/-12 years, BMI 26.1+/-3.8 kg/m(2)) and 10 matched healthy controls (negative family history, 6 male, 4 female, 45+/-13 years, 26.1+/-4.2 kg/m(2)) were examined with an oral glucose load (75 g...

  8. Slow ultrafiltration for continuous in vivo sampling : application for glucose and lactate in man

    NARCIS (Netherlands)

    Tiessen, RG; Kaptein, WA; Venema, K; Korf, J

    1999-01-01

    Background: An ultrafiltration (UF) technique was developed for continuous subcutaneous (s.c.) sampling and on-line analysis of absolute glucose and lactate concentrations in tissue. The relation between subcutaneous and blood concentrations was studied in men, because a subcutaneous monitoring

  9. Glucose-stimulated prehepatic insulin secretion is associated with circulating alanine, triglyceride, glucagons, lactate and TNF-alfa in patients with HIV-lipodystrophy

    DEFF Research Database (Denmark)

    Haugaard, Steen B; Andersen, Ove; Pedersen, SB

    2006-01-01

    with the remaining HIV-infected patients (all Ptriglyceride, alanine, glucagon, lactate and TNF-alpha may be associated with alterations in the first-phase prehepatic insulin secretion response to intravenous glucose in normoglycaemic lipodystrophic HIV-infected patients.......OBJECTIVES: We examined whether insulin-resistant lipodystrophic HIV-infected patients with known high fasting prehepatic insulin secretion rates (FISRs) displayed alterations in first-phase prehepatic insulin response to intravenous glucose (ISREG0-10 min). METHODS: Eighteen normoglycaemic...... lipodystrophic HIV-infected (LIPO) patients and 25 normoglycaemic nonlipodystrophic HIV-infected patients (controls) were included in the study. The prehepatic insulin secretion rate was estimated by deconvolution of C-peptide concentrations, and insulin sensitivity (SIRd) was estimated by the glucose clamp...

  10. Glucose-stimulated prehepatic insulin secretion is associated with circulating alanine, triglyceride, glucagon, lactate and TNF-alpha in patients with HIV-lipodystrophy

    DEFF Research Database (Denmark)

    Haugaard, S B; Andersen, O; Pedersen, S B

    2006-01-01

    with the remaining HIV-infected patients (all Ptriglyceride, alanine, glucagon, lactate and TNF-alpha may be associated with alterations in the first-phase prehepatic insulin secretion response to intravenous glucose in normoglycaemic lipodystrophic HIV-infected patients.......OBJECTIVES: We examined whether insulin-resistant lipodystrophic HIV-infected patients with known high fasting prehepatic insulin secretion rates (FISRs) displayed alterations in first-phase prehepatic insulin response to intravenous glucose (ISREG0-10 min). METHODS: Eighteen normoglycaemic...... lipodystrophic HIV-infected (LIPO) patients and 25 normoglycaemic nonlipodystrophic HIV-infected patients (controls) were included in the study. The prehepatic insulin secretion rate was estimated by deconvolution of C-peptide concentrations, and insulin sensitivity (SIRd) was estimated by the glucose clamp...

  11. Histidine Augments the Suppression of Hepatic Glucose Production by Central Insulin Action

    OpenAIRE

    Kimura, Kumi; Nakamura, Yusuke; Inaba, Yuka; Matsumoto, Michihiro; Kido, Yoshiaki; Asahara, Shun-ichiro; Matsuda, Tomokazu; Watanabe, Hiroshi; Maeda, Akifumi; Inagaki, Fuyuhiko; Mukai, Chisato; Takeda, Kiyoshi; Akira, Shizuo; Ota, Tsuguhito; Nakabayashi, Hajime

    2013-01-01

    Glucose intolerance in type 2 diabetes is related to enhanced hepatic glucose production (HGP) due to the increased expression of hepatic gluconeogenic enzymes. Previously, we revealed that hepatic STAT3 decreases the expression of hepatic gluconeogenic enzymes and suppresses HGP. Here, we show that increased plasma histidine results in hepatic STAT3 activation. Intravenous and intracerebroventricular (ICV) administration of histidine-activated hepatic STAT3 reduced G6Pase protein and mRNA le...

  12. Impaired first-phase insulin response predicts postprandial blood glucose increment in patients with recently diagnosed type 2 diabetes

    DEFF Research Database (Denmark)

    Gredal, C; Rosenfalck, A M; Dejgaard, Anders

    2007-01-01

    The aim of the study was to evaluate the relationship between postprandial blood glucose and first-phase insulin response and, furthermore, to assess whether the intravenous glucagon stimulation test can be used as a predictor for increased postprandial glucose in patients with recently diagnosed...... type 2 diabetes....

  13. Effects of administration route, dietary condition, and blood glucose level on kinetics and uptake of 18F-FDG in mice.

    Science.gov (United States)

    Wong, Koon-Pong; Sha, Wei; Zhang, Xiaoli; Huang, Sung-Cheng

    2011-05-01

    The effects of dietary condition and blood glucose level on the kinetics and uptake of (18)F-FDG in mice were systematically investigated using intraperitoneal and tail-vein injection. Dynamic PET was performed for 60 min on 23 isoflurane-anesthetized male C57BL/6 mice after intravenous (n = 11) or intraperitoneal (n = 12) injection of (18)F-FDG. Five and 6 mice in the intravenous and intraperitoneal groups, respectively, were kept fasting overnight (18 ± 2 h), and the others were fed ad libitum. Serial blood samples were collected from the femoral artery to measure (18)F-FDG and glucose concentrations. Image data were reconstructed using filtered backprojection with CT-based attenuation correction. The standardized uptake value (SUV) was estimated from the 45- to 60-min image. The metabolic rate of glucose (MRGlu) and (18)F-FDG uptake constant (K(i)) were derived by Patlak graphical analysis. In the brain, SUV and K(i) were significantly higher in fasting mice with intraperitoneal injection, but MRGlu did not differ significantly under different dietary states and administration routes. Cerebral K(i) was inversely related to elevated blood glucose levels, irrespective of administration route or dietary state. In myocardium, SUV, K(i), and MRGlu were significantly lower in fasting than in nonfasting mice for both routes of injection. Myocardial SUV and K(i) were strongly dependent on the dietary state, and K(i) did not correlate with the blood glucose level. Similar results were obtained for skeletal muscle, although the differences were not as pronounced. Intraperitoneal injection is a valid alternative route, providing pharmacokinetic data equivalent to data from tail-vein injection for small-animal (18)F-FDG PET. Cerebral K(i) varies inversely with blood glucose level, but the measured cerebral MRGlu does not correlate with blood glucose level or dietary condition. Conversely, the K(i) values of the myocardium and skeletal muscle are strongly dependent on

  14. Chemical exchange-sensitive spin-lock MRI of glucose analog 3-O-methyl-d-glucose in normal and ischemic brain.

    Science.gov (United States)

    Jin, Tao; Mehrens, Hunter; Wang, Ping; Kim, Seong-Gi

    2018-05-01

    Glucose transport is important for understanding brain glucose metabolism. We studied glucose transport with a presumably non-toxic and non-metabolizable glucose analog, 3-O-methyl-d-glucose, using a chemical exchange-sensitive spin-lock MRI technique at 9.4 Tesla. 3-O-methyl-d-glucose showed comparable chemical exchange properties with d-glucose and 2-deoxy-d-glucose in phantoms, and higher and lower chemical exchange-sensitive spin-lock sensitivity than Glc and 2-deoxy-d-glucose in in vivo experiments, respectively. The changes of the spin-lattice relaxation rate in the rotating frame (Δ R 1 ρ) in normal rat brain peaked at ∼15 min after the intravenous injection of 1 g/kg 3-O-methyl-d-glucose and almost maintained a plateau for >1 h. Doses up to 4 g/kg 3-O-methyl-d-glucose were linearly correlated with Δ R 1 ρ. In rats with focal ischemic stroke, chemical exchange-sensitive spin-lock with 3-O-methyl-d-glucose injection at 1 h after stroke onset showed reduced Δ R 1 ρ in the ischemic core but higher Δ R 1 ρ in the peri-core region compared to normal tissue, which progressed into the ischemic core at 3 h after stroke onset. This suggests that the hyper-chemical exchange-sensitive spin-lock region observed at 1 h is the ischemic penumbra at-risk of infarct. In summary, 3-O-methyl-d-glucose-chemical exchange-sensitive spin-lock can be a sensitive MRI technique to probe the glucose transport in normal and ischemic brains.

  15. Regional cerebral energy metabolism during intravenous anesthesia with etomidate, ketamine or thiopental

    International Nuclear Information System (INIS)

    Davis, D.W.

    1987-01-01

    Regional brain glucose utilization (rCMRglc) was measured in rats during steady-state levels of intravenous anesthesia to determine if alterations in brain function due to anesthesia could provide information on the mechanisms of anesthesia. Intravenous anesthetics from three different chemical classes were studied: etomidate, ketamine and thiopental. All rCMRglc experiments were conducted in freely moving rats in isolation chambers, with the use of [6- 14 C] glucose and guantitative autoradiography. Etomidate caused a rostral-to-caudal gradient of depression of rCMRglc. The four doses of etomidate did not differ in their effects on energy metabolism. Sub-anesthetic (5 mg kg -1 ) and anesthetic (30 mg kg -1 ) doses of ketamine produced markedly different patterns of behavior. Brain energy metabolism during the sub-anesthetic dose was stimulated in most regions, while the anesthetic dose selectively stimulated the hippocampus, leaving most brain regions unaffected. Thiopental produced a dose-dependent reduction of rCMRglc in all gray matter regions. No brain region was selectively affected. Comparison of the drug-specific alterations of cerebral energy metabolism suggests these anesthetics do not act through a common mechanism. The hypothesis that each acts by binding to specific cell membrane receptors is consistent with these observations

  16. Sequential enzymatic derivatization coupled with online microdialysis sampling for simultaneous profiling of mouse tumor extracellular hydrogen peroxide, lactate, and glucose.

    Science.gov (United States)

    Su, Cheng-Kuan; Tseng, Po-Jen; Chiu, Hsien-Ting; Del Vall, Andrea; Huang, Yu-Fen; Sun, Yuh-Chang

    2017-03-01

    Probing tumor extracellular metabolites is a vitally important issue in current cancer biology. In this study an analytical system was constructed for the in vivo monitoring of mouse tumor extracellular hydrogen peroxide (H 2 O 2 ), lactate, and glucose by means of microdialysis (MD) sampling and fluorescence determination in conjunction with a smart sequential enzymatic derivatization scheme-involving a loading sequence of fluorogenic reagent/horseradish peroxidase, microdialysate, lactate oxidase, pyruvate, and glucose oxidase-for step-by-step determination of sampled H 2 O 2 , lactate, and glucose in mouse tumor microdialysate. After optimization of the overall experimental parameters, the system's detection limit reached as low as 0.002 mM for H 2 O 2 , 0.058 mM for lactate, and 0.055 mM for glucose, based on 3 μL of microdialysate, suggesting great potential for determining tumor extracellular concentrations of lactate and glucose. Spike analyses of offline-collected mouse tumor microdialysate and monitoring of the basal concentrations of mouse tumor extracellular H 2 O 2 , lactate, and glucose, as well as those after imparting metabolic disturbance through intra-tumor administration of a glucose solution through a prior-implanted cannula, were conducted to demonstrate the system's applicability. Our results evidently indicate that hyphenation of an MD sampling device with an optimized sequential enzymatic derivatization scheme and a fluorescence spectrometer can be used successfully for multi-analyte monitoring of tumor extracellular metabolites in living animals. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. The effect of genetically engineered glucagon on glucose recovery after hypoglycaemia in man

    DEFF Research Database (Denmark)

    Hvidberg, A; Jørgensen, S; Hilsted, J

    1992-01-01

    To compare the effect on glucose recovery after insulin-induced hypoglycaemia of intramuscular genetically engineered glucagon, intramuscular glucagon from pancreatic extraction and intravenous glucose, we examined 10 healthy subjects during blockage of glucose counterregulation with somatostatin...... appearance rate were far more protracted after i.m. glucagon than after i.v. glucose. These results suggest that genetically engineered glucagon and glucagon from pancreatic extraction have a similar effect on hepatic glucose production rate. Due to the protracted effect of intramuscular glucagon, a combined......, propranolol and phentolamine. Each subject was studied on three separate occasions. Thirty min after a bolus injection of 0.075 iu soluble insulin per kilogram body weight the subjects received one of the following treatments: 1 mg glucagon from pancreatic extraction intramuscularly; 1 mg genetically...

  18. The effects of incretin hormones on cerebral glucose metabolism in health and disease

    DEFF Research Database (Denmark)

    Nilsson, Malin; Gjedde, Albert; Brock, Birgitte

    2017-01-01

    Incretin hormones, notably glucagon-like peptide-1 (GLP-1), are gluco-regulatory hormones with pleiotropic effects also in the central nervous system. Apart from a local production of GLP-1, systemic administration of the hormone has been shown to influence a number of cerebral pathologies......, including neuroinflammation. Given the brains massive dependence on glucose as its major fuel, we here review the mechanistics of cerebral glucose transport and metabolism, focusing on the deleterious effects of both hypo- and hyperglycaemia. GLP-1, when administered as long-acting analogues...... or intravenously, appears to decrease transport of glucose in normoglycaemic conditions, without affecting the total cerebral glucose content. During hypoglycaemia this effect seems abated, whereas during hyperglycaemia GLP-1 regulates cerebral glucose metabolism towards stable levels resembling normoglycaemia...

  19. Effects of Rapid Intravenous Rehydration in Children With Mild-to-Moderate Dehydration.

    Science.gov (United States)

    Janet, Sophie; Molina, Juan Carlos; Marañón, Rafael; García-Ros, Marta

    2015-08-01

    New guidelines for "rapid or ultrarapid" intravenous rehydration are being developed in different emergency departments. These new guidelines propose a faster administration of fluids and electrolytes than in traditional protocols. However, there is still insufficient evidence to establish a standard protocol. Our objective was to determine the effects of an outpatient rapid intravenous rehydration regimen based on the administration of 0.9% saline + 2.5% dextrose, at a rate of 20 mL/kg per hour for 2 hours, in children with mild-to-moderate isonatremic dehydration resulting from acute gastroenteritis. We performed a 2-institution, prospective, observational, descriptive study. Eighty-three patients were included in the study. All patients underwent a first evaluation, including physical examination, laboratory tests, and assessment of clinical degree of dehydration. After this initial evaluation, all children received our intravenous rehydration regimen. A second evaluation including the same items as in the first one was made after in all the children. Intravenous rehydration was successful in 69 patients (83.1%). It failed in 14 patients (16.8%), who required hospitalization because of persistent vomiting in 9 patients and poor general appearance in 5 patients. After intravenous rehydration, we observed a statistically significant decrease in the levels of ketonemia and uremia and in the Gorelick scale score. However, no significant changes were observed in sodium, chloride, potassium, and osmolarity values. We conclude that, in children with mild-to-moderate dehydration, the administration of 20 mL/kg per hour for 2 hours of 0.9% saline solution + 2.5% glucose improved clinical scores and may be used as an alternative and safe way for intravenous rehydration.

  20. Glucose phosphorylation rate in rat parietal cortex during normoglycemia, hypoglycemia, acute hyperglycemia, and in diabetes-prone rats

    Energy Technology Data Exchange (ETDEWEB)

    Broendsted, H.E.; Gjedde, A. (Department of General Physiology and Biophysics, Panum Institute, University of Copenhagen (Denmark))

    1990-01-01

    Cerebral metabolic rate for glucose (CMRglc) was studied in rats using (6-{sup 14}C)glucose. After intravenous injection the radioactivity of the parietal cortex was corrected for loss of labeled CO{sub 2} and divided by the integral of the arterial plasma glucose concentration, determined during tracer circulation. Treatment with insulin, resulting in plasma glucose concentrations less than 2.6 mmol/l, reduced CMRglc to 64% of the values found in control animals. CMRglc did not change in animals with acute hyper-glycemia produced by intraperiotoneal injection of a glucose solution or in diabetes-prone rats with or withour insulin treatment. (author).

  1. Glucose phosphorylation rate in rat rarietal cortex during normoglycemia, hypoglycemia, acute hyperglycemia, and in diabetes-prone rats

    International Nuclear Information System (INIS)

    Broendsted, H.E.; Gjedde, A.

    1990-01-01

    Cerebral metabolic rate for glucose (CMRglc) was studied in rats using [6- 14 C]glucose. After intravenous injection the radioactivity of the parietal cortex was corrected for loss of labeled CO 2 and divided by the integral of the arterial plasma glucose concentration, determined during tracer circulation. Treatment with insulin, resulting in plasma glucose concentrations less than 2.6 mmol/l, reduced CMRglc to 64% of the values found in control animals. CMRglc did not change in animals with acute hyper-glycemia produced by intraperiotoneal injection of a glucose solution or in diabetes-prone rats with or withour insulin treatment. (author)

  2. A variant in the G6PC2/ABCB11 locus is associated with increased fasting plasma glucose, increased basal hepatic glucose production and increased insulin release after oral and intravenous glucose loads

    DEFF Research Database (Denmark)

    Rose, C S; Grarup, N; Krarup, N T

    2009-01-01

    An association between elevated fasting plasma glucose and the common rs560887 G allele in the G6PC2/ABCB11 locus has been reported. In Danes we aimed to examine rs560887 in relation to plasma glucose and serum insulin responses following oral and i.v. glucose loads and in relation to hepatic...... glucose production during a hyperinsulinaemic-euglycaemic clamp. Furthermore, we examined rs560887 for association with impaired fasting glycaemia (IFG), impaired glucose tolerance (IGT), type 2 diabetes and components of the metabolic syndrome....

  3. Intraperitoneal Glucose Sensing is Sometimes Surprisingly Rapid

    Directory of Open Access Journals (Sweden)

    Anders Lyngvi Fougner

    2016-04-01

    Full Text Available Rapid, accurate and robust glucose measurements are needed to make a safe artificial pancreas for the treatment of diabetes mellitus type 1 and 2. The present gold standard of continuous glucose sensing, subcutaneous (SC glucose sensing, has been claimed to have slow response and poor robustness towards local tissue changes such as mechanical pressure, temperature changes, etc. The present study aimed at quantifying glucose dynamics from central circulation to intraperitoneal (IP sensor sites, as an alternative to the SC location. Intraarterial (IA and IP sensors were tested in three anaesthetized non-diabetic pigs during experiments with intravenous infusion of glucose boluses, enforcing rapid glucose level excursions in the range 70--360 mg/dL (approximately 3.8--20 mmol/L. Optical interferometric sensors were used for IA and IP measurements. A first-order dynamic model with time delay was fitted to the data after compensating for sensor dynamics. Additionally, off-the-shelf Medtronic Enlite sensors were used for illustration of SC glucose sensing. The time delay in glucose excursions from central circulation (IA to IP sensor location was found to be in the range 0--26 s (median: 8.5 s, mean: 9.7 s, SD 9.5 s, and the time constant was found to be 0.5--10.2 min (median: 4.8 min, mean: 4.7 min, SD 2.9 min. IP glucose sensing sites have a substantially faster and more distinctive response than SC sites when sensor dynamics is ignored, and the peritoneal fluid reacts even faster to changes in intravascular glucose levels than reported in previous animal studies. This study may provide a benchmark for future, rapid IP glucose sensors.

  4. Impaired incretin effect is an early sign of glucose dysmetabolism in nondiabetic patients with psoriasis

    DEFF Research Database (Denmark)

    Gyldenløve, M; Lauritsen, Tina Vilsbøll; Zachariae, Claus

    2015-01-01

    BACKGROUND: Patients with psoriasis have an increased risk of type 2 diabetes. The gastrointestinal system plays a major role in normal glucose metabolism, and in healthy individuals, postprandial insulin secretion is largely mediated by the gut incretin hormones. This potentiation is termed...... the incretin effect and is reduced in type 2 diabetes. The impact of psoriasis on gastrointestinal factors involved in glucose metabolism has not previously been examined. OBJECTIVE: To investigate whether the incretin effect, gastrointestinal-mediated glucose disposal (GIGD) and/or secretion of glucagon...... and gut incretin hormones are impaired in normal glucose-tolerant patients with psoriasis. METHODS: Oral glucose tolerance tests and intravenous isoglycaemic glucose infusions were performed in 12 patients with moderate-to-severe psoriasis and 12 healthy matched control subjects. RESULTS: In patients...

  5. Hypothalamic and Striatal Insulin Action Suppresses Endogenous Glucose Production and May Stimulate Glucose Uptake During Hyperinsulinemia in Lean but Not in Overweight Men.

    Science.gov (United States)

    Heni, Martin; Wagner, Robert; Kullmann, Stephanie; Gancheva, Sofiya; Roden, Michael; Peter, Andreas; Stefan, Norbert; Preissl, Hubert; Häring, Hans-Ulrich; Fritsche, Andreas

    2017-07-01

    Intranasal spray application facilitates insulin delivery to the human brain. Although brain insulin modulates peripheral metabolism, the mechanisms involved remain elusive. Twenty-one men underwent two hyperinsulinemic-euglycemic clamps with d-[6,6- 2 H 2 ]glucose infusion to measure endogenous glucose production and glucose disappearance. On two separate days, participants received intranasal insulin or placebo. Insulin spillover into circulation after intranasal insulin application was mimicked by an intravenous insulin bolus on placebo day. On a different day, brain insulin sensitivity was assessed by functional MRI. Glucose infusion rates (GIRs) had to be increased more after nasal insulin than after placebo to maintain euglycemia in lean but not in overweight people. The increase in GIRs was associated with regional brain insulin action in hypothalamus and striatum. Suppression of endogenous glucose production by circulating insulin was more pronounced after administration of nasal insulin than after placebo. Furthermore, glucose uptake into tissue tended to be higher after nasal insulin application. No such effects were detected in overweight participants. By increasing insulin-mediated suppression of endogenous glucose production and stimulating peripheral glucose uptake, brain insulin may improve glucose metabolism during systemic hyperinsulinemia. Obese people appear to lack these mechanisms. Therefore, brain insulin resistance in obesity may have unfavorable consequences for whole-body glucose homeostasis. © 2017 by the American Diabetes Association.

  6. Comparison of palmitic acid kinetics during glucose or ketone body infusions

    Energy Technology Data Exchange (ETDEWEB)

    Birkhahn, R.H.; Block, D.J.; Birkhahn, G.C.; Thomford, N.R.

    1986-03-05

    Ketone body interactions can be observed for extended ketosis by infusion by monoacetoacetin (the monoglyceride of acetoacetic acid). Palmitic acid kinetics were compared on the 5th day of glucose or ketone body-glucose infusions. 20 rats were fed complete diets intravenously at the rate of 50 ml/day. All diets contained vitamins, trace minerals, electrolytes, amino acids and 1 kcal/ml of non-protein energy. Rats were divided by energy source: Group A (n = 10) received energy from glucose and Group B (n = 10) from 72% monoacetoacetin plus 28% glucose. Diets were given at 1/2 and 3/4 rats on days 1 and 2, respectively and at full rate for days 3-5. Urinary nitrogen losses, body weight and dietary intake were measured daily. Palmitate kinetics was measured on day 5 using a continuous infusion of (1-/sup 14/C) palmitate and measuring C-14 in breath and plasma and plasma palmitate by GC. The two groups had similar body weight changes and urinary nitrogen losses over the 3 days of full intake Group A had lower plasma palmitate (88 +/- 7 vs 105 +/- 6 micromol/l) but similar turnover (17.1 +/- 2.4 vs 15.0 +/- 1.9 mmol/hr) and oxidation 2.3 +/- 0.3 vs 2.2 +/- 0.05 mmol/hr) compared to Group B. These data show that feeding monoacetoacetin intravenously does not stimulate fatty acid metabolism in the well nourished rat.

  7. Comparison of palmitic acid kinetics during glucose or ketone body infusions

    International Nuclear Information System (INIS)

    Birkhahn, R.H.; Block, D.J.; Birkhahn, G.C.; Thomford, N.R.

    1986-01-01

    Ketone body interactions can be observed for extended ketosis by infusion by monoacetoacetin (the monoglyceride of acetoacetic acid). Palmitic acid kinetics were compared on the 5th day of glucose or ketone body-glucose infusions. 20 rats were fed complete diets intravenously at the rate of 50 ml/day. All diets contained vitamins, trace minerals, electrolytes, amino acids and 1 kcal/ml of non-protein energy. Rats were divided by energy source: Group A (n = 10) received energy from glucose and Group B (n = 10) from 72% monoacetoacetin plus 28% glucose. Diets were given at 1/2 and 3/4 rats on days 1 and 2, respectively and at full rate for days 3-5. Urinary nitrogen losses, body weight and dietary intake were measured daily. Palmitate kinetics was measured on day 5 using a continuous infusion of [1- 14 C] palmitate and measuring C-14 in breath and plasma and plasma palmitate by GC. The two groups had similar body weight changes and urinary nitrogen losses over the 3 days of full intake Group A had lower plasma palmitate (88 +/- 7 vs 105 +/- 6 micromol/l) but similar turnover (17.1 +/- 2.4 vs 15.0 +/- 1.9 mmol/hr) and oxidation 2.3 +/- 0.3 vs 2.2 +/- 0.05 mmol/hr) compared to Group B. These data show that feeding monoacetoacetin intravenously does not stimulate fatty acid metabolism in the well nourished rat

  8. Application of rapid-sampling, online microdialysis to the monitoring of brain metabolism during aneurysm surgery.

    Science.gov (United States)

    Bhatia, Robin; Hashemi, Parastoo; Razzaq, Ashfaq; Parkin, Mark C; Hopwood, Sarah E; Boutelle, Martyn G; Strong, Anthony J

    2006-04-01

    To introduce rapid-sampling microdialysis for the early detection of adverse metabolic changes in tissue at risk during aneurysm surgery. A microdialysis catheter was inserted under direct vision into at-risk cortex at the start of surgery. This monitoring was sustained throughout the course of the operation, during which intraoperative events, for example, temporary arterial occlusion or lobe retraction, were precisely documented. A continuous online flow of dialysate was fed into a mobile bedside glucose and lactate analyser. This comprises flow-injection dual-assay enzyme-based biosensors capable of determining values of metabolites every 30 seconds. Eight patients underwent clipping or wrapping of intracranial aneurysms and were monitored. Time between events and detection: 9 minutes. Mean change in metabolite value +/- standard deviation: temporal lobe retraction lactate, +656 +/- 562 micromol/L (n = 7, P glucose, -123 +/- 138 micromol/L (n = 6, P = 0.08). Glucose intravenous bolus infusion glucose, +512 +/- 244 micromol/L (n = 5, P lactate, +731 +/- 346 micromol/L (n = 6, P glucose, -139 +/- 96 micromol/L (n = 5, P glucose and lactate in dialysate, particularly when rapid, transient changes in brain analyte levels need to be determined and the alternative offline methodology would be inadequate.

  9. Determination of the optional time for taking blood samples by single intravenous injection of 3H-leucine

    International Nuclear Information System (INIS)

    Meng Delian; Yao Junhu; Lu Jinyin; Wu Xiaobin; Liu Jun

    2003-01-01

    Twenty four young hens (1.5 kg of body weight, BW) were randomly divided into 4 groups. Every group was diet free (FAS) or force-fed a nitrogen-free diet (NFD) or the diet with 20% crude protein in which soybean meal or cotton seed meal was the sole nitrogen source (30 g DM/kg BW). 30 μCi 3 H-Leu/kg BW was intravenously injected into all birds just after force-fed or on fasting. Venous blood samples were taken at 5, 30 min, 4,24,36 and 48h after injection. The excreta during the whole period of 48h after injection was collected. Special radioactivities of nonprotein plasma at every time point and excreta were measured. The optional time of taking blood samples was 20-24 hours after injected 3 H-Leu

  10. Treatment of post-operative pain in old oncology patients with intravenous application of 50% glucose solution

    Directory of Open Access Journals (Sweden)

    Jovanović Nikola Č.

    2003-01-01

    Full Text Available Postoperative pain is the most important factor od so called "tumor promotive effect of surgery" ie. of endocrine-metabolic changes having the consequence drop in immune, antiinfective and antitumor defense. Due to presence of organic involutive changes, old people (≥ 65 years, often have serious side effects during application of usual analgetics. Since hypertonic glucose (33% given i.v. or per os, works analgesically in small children there is assumption that it can be used in treatment of postoperative pain in old oncology patients. We tested the hypothesis that postoperative pain in old oncology patients can be treated with i.v. application of 50% of glucose solution. 37 oncology patients over 65 years, 26 females and 11 males, operated for breast cancer and soft tissue cancer, werw investigated. Average age of the patients was 72±4 years. 50% Glucose solution was given in two boluses of 20 ml each: the first bolus was given to all patients at the end of anesthesia and the other bolus was given individually after appearance of post-operative pain. Pain intensity (in coefficients of the visual analogue scale VAK = 1-100 and its characteristics were tested by oral testing of operated patients: after weaking from anesthesia, after the first appearance of the pain and 15 minutes after giving of the second glucose bolus. None patient had pain weaking from anesthesia. All tested patients experienced pain during the first 70 minutes and it could be categorized as very strong pain (=82 VAK. The pain was decreased with another glucose bolus by approximately (=56% VAK so it was classifies in category of bearable pains (=36 VAK. In 9 patients (24,3% the pain had neuropatic component (filing of "burning" which could not be eliminated by hypertonic glucose but only with application of tramadol. Activation of the central cholinergic transmission is the most significant mechanism of analgesic glucose effect, but, probably there is another one

  11. Postprandial glucose response to selected tropical fruits in normal glucose-tolerant Nigerians.

    Science.gov (United States)

    Edo, A; Eregie, A; Adediran, O; Ohwovoriole, A; Ebengho, S

    2011-01-01

    The glycemic response to commonly eaten fruits in Nigeria has not been reported. Therefore, this study assessed the plasma glucose response to selected fruits in Nigeria. Ten normal glucose-tolerant subjects randomly consumed 50 g carbohydrate portions of three fruits: banana (Musa paradisiaca), pineapple (Ananus comosus), and pawpaw (Carica papaya), and a 50-g glucose load at 1-week intervals. Blood samples were collected in the fasting state and half-hourly over a 2-h period post-ingestion of the fruits or glucose. The samples were analyzed for plasma glucose concentrations. Plasma glucose responses were assessed by the peak plasma glucose concentration, maximum increase in plasma glucose, 2-h postprandial plasma glucose level, and incremental area under the glucose curve and glycemic index (GI). The results showed that the blood glucose response to these three fruits was similar in terms of their incremental areas under the glucose curve, maximum increase in plasma glucose, and glycemic indices (GIs). The 2-h postprandial plasma glucose level of banana was significantly higher than that of pineapple, P < 0.025. The mean ± SEM GI values were as follows: pawpaw; 86 ± 26.8%; banana, 75.1 ± 21.8%; pineapple, 64.5 ± 11.3%. The GI of glucose is taken as 100. The GI of pineapple was significantly lower than that of glucose (P < 0.05). Banana, pawpaw, and pineapple produced a similar postprandial glucose response. Measured portions of these fruits may be used as fruit exchanges with pineapple having the most favorable glycemic response.

  12. Production of rabbit antibodies against purified Glucose oxidase

    Directory of Open Access Journals (Sweden)

    Muhammad Anjum Zia

    2012-02-01

    Full Text Available Glucose oxidase is an active oxygen species generating enzyme produced from Aspergillus niger grown in submerged fermentation. Disintegration of the mycelium resulted in high glucose oxidase activity that was subjected to ammonium sulfate precipitation at 60-85% saturation rates that resulted to 6.14 U mg -1 specific activity. Purification of enzyme by anion exchange column (DEAE-Cellulose resulted into 22.53 U mg-1 specific activity and 10.27 fold purification. This was applied to sephadex G-200 column for gel filtration chromatography. It was observed that enzyme achieved 59.37 U mg-1of specific activity with 27.08 fold purity and 64.36% recovery. Purified glucose oxidase was injected into rabbits through intravenous route, to raise the glucose oxidase antibodies. After 30 days incubation period, the rabbits were slaughtered and serum was separated from blood. The antibodies were isolated by ammonium sulfate precipitation and confirmed by agar gel precipitation test. This could be a convenient and low cost alternate assay for the estimation of glucose oxidase in biological fluids. Moreover, such antibodies against the said enzyme could be used in various therapeutic and diagnostic applications.

  13. The association between estimated average glucose levels and fasting plasma glucose levels

    Directory of Open Access Journals (Sweden)

    Giray Bozkaya

    2010-01-01

    Full Text Available OBJECTIVE: The level of hemoglobin A1c (HbA1c, also known as glycated hemoglobin, determines how well a patient's blood glucose level has been controlled over the previous 8-12 weeks. HbA1c levels help patients and doctors understand whether a particular diabetes treatment is working and whether adjustments need to be made to the treatment. Because the HbA1c level is a marker of blood glucose for the previous 120 days, average blood glucose levels can be estimated using HbA1c levels. Our aim in the present study was to investigate the relationship between estimated average glucose levels, as calculated by HbA1c levels, and fasting plasma glucose levels. METHODS: The fasting plasma glucose levels of 3891 diabetic patient samples (1497 male, 2394 female were obtained from the laboratory information system used for HbA1c testing by the Department of Internal Medicine at the Izmir Bozyaka Training and Research Hospital in Turkey. These samples were selected from patient samples that had hemoglobin levels between 12 and 16 g/dL. The estimated glucose levels were calculated using the following formula: 28.7 x HbA1c - 46.7. Glucose and HbA1c levels were determined using hexokinase and high performance liquid chromatography (HPLC methods, respectively. RESULTS: A strong positive correlation between fasting plasma glucose levels and estimated average blood glucose levels (r=0.757, p<0.05 was observed. The difference was statistically significant. CONCLUSION: Reporting the estimated average glucose level together with the HbA1c level is believed to assist patients and doctors determine the effectiveness of blood glucose control measures.

  14. Alterations in glucose kinetics induced by pentobarbital anesthesia

    International Nuclear Information System (INIS)

    Lang, C.H.; Bagby, G.J.; Hargrove, D.M.; Hyde, P.M.; Spitzer, J.J.

    1987-01-01

    Because pentobarbital is often used in investigations related to carbohydrate metabolism, the in vivo effect of this drug on glucose homeostasis was studied. Glucose kinetics assessed by the constant intravenous infusion of [6- 3 H]- and [U- 14 C]glucose, were determined in three groups of catheterized fasted rats: conscious, anesthetized and body temperature maintained, and anesthetized but body temperature not maintained. After induction of anesthesia, marked hypothermia developed in rats not provided with external heat. Anesthetized rats that developed hypothermia showed a decrease in mean arterial blood pressure (25%) and heart rate (40%). Likewise, the plasma lactate concentration and the rates of glucose appearance, recycling, and metabolic clearance were reduced by 30-50% in the hypothermic anesthetized rats. Changes in whole-body carbohydrate metabolism were prevented when body temperature was maintained. Because plasma pentobarbital levels were similar between the euthermic and hypothermic rats during the first 2 h of the experiment, the rapid reduction in glucose metabolism in this latter group appears related to the decrease in body temperature. The continuous infusion of epinephrine produced alterations in glucose kinetics that were not different between conscious animals and anesthetized rats with body temperature maintained. Thus pentobarbital-anesthetized rats became hypothermic when kept at room temperature and exhibited marked decreases in glucose metabolism. Such changes were absent when body temperature was maintained during anesthesia

  15. Glucose uptake and pulsatile insulin infusion: euglycaemic clamp and [3-3H]glucose studies in healthy subjects

    International Nuclear Information System (INIS)

    Schmitz, O.; Arnfred, J.; Hother Nielsen, O.; Beck-Nielsen, H.; Oerskov, H.

    1986-01-01

    To test the hypothesis that insulin has a greater effect on glucose metabolism when given as pulsatile than as continuous infusion, a 354-min euglycaemic clamp study was carried out in 8 healthy subjects. At random order soluble insulin was given intravenously either at a constant rate of 0.45mU/kg · min or in identical amounts in pulses of 1 1 / 2 to 2 1 / 4 min followed by intervals of 10 1 / 2 to 9 3 / 4 min. Average serum insulin levels were similar during the two infusion protocols, but pulsatile administration induced oscillations ranging between 15 and 62 μU/ml. Glucose uptake expressed as metabolic clearance rate (MCR) for glucose was significantly increased during pulsatile insulin delivery as compared with continuous administration (270-294 min: 8.7±0.7 vs 6.8±0.9 ml/kg · min, P 3 H]glucose infusion technique was suppressed to insignificant values. Finally, the effect of insulin on endogenous insulin secretion and lipolysis as assessed by changes in serum C-peptide and serum FFA was uninfluenced by the infusion mode. In conclusion, insulin infusion resulting in physiological serum insulin levels enhances glucose uptake in peripheral tissues in healthy subjects to a higher degree when given in a pulsed pattern mimicking that of the normal endocrine pancreas than when given as a continuous infusion. (author)

  16. Impact of Glucose Meter Error on Glycemic Variability and Time in Target Range During Glycemic Control After Cardiovascular Surgery.

    Science.gov (United States)

    Karon, Brad S; Meeusen, Jeffrey W; Bryant, Sandra C

    2015-08-25

    We retrospectively studied the impact of glucose meter error on the efficacy of glycemic control after cardiovascular surgery. Adult patients undergoing intravenous insulin glycemic control therapy after cardiovascular surgery, with 12-24 consecutive glucose meter measurements used to make insulin dosing decisions, had glucose values analyzed to determine glycemic variability by both standard deviation (SD) and continuous overall net glycemic action (CONGA), and percentage glucose values in target glucose range (110-150 mg/dL). Information was recorded for 70 patients during each of 2 periods, with different glucose meters used to measure glucose and dose insulin during each period but no other changes to the glycemic control protocol. Accuracy and precision of each meter were also compared using whole blood specimens from ICU patients. Glucose meter 1 (GM1) had median bias of 11 mg/dL compared to a laboratory reference method, while glucose meter 2 (GM2) had a median bias of 1 mg/dL. GM1 and GM2 differed little in precision (CV = 2.0% and 2.7%, respectively). Compared to the period when GM1 was used to make insulin dosing decisions, patients whose insulin dose was managed by GM2 demonstrated reduced glycemic variability as measured by both SD (13.7 vs 21.6 mg/dL, P meter error (bias) was associated with decreased glycemic variability and increased percentage of values in target glucose range for patients placed on intravenous insulin therapy following cardiovascular surgery. © 2015 Diabetes Technology Society.

  17. A comprehensive compartmental model of blood glucose regulation for healthy and type 2 diabetic subjects

    DEFF Research Database (Denmark)

    Vahidi, O; Kwok, K E; Gopaluni, R B

    2016-01-01

    We have expanded a former compartmental model of blood glucose regulation for healthy and type 2 diabetic subjects. The former model was a detailed physiological model which considered the interactions of three substances, glucose, insulin and glucagon on regulating the blood sugar. The main...... variations of blood glucose concentrations following an oral glucose intake. Another model representing the incretins production in the gastrointestinal tract along with their hormonal effects on boosting pancreatic insulin production is also added to the former model. We have used two sets of clinical data...... obtained during oral glucose tolerance test and isoglycemic intravenous glucose infusion test from both type 2 diabetic and healthy subjects to estimate the model parameters and to validate the model results. The estimation of model parameters is accomplished through solving a nonlinear optimization...

  18. Evaluation of the stability of linezolid in aqueous solution and commonly used intravenous fluids

    Directory of Open Access Journals (Sweden)

    Taylor R

    2017-07-01

    Full Text Available Rachel Taylor, Bruce Sunderland, Giuseppe Luna, Petra Czarniak School of Pharmacy, Faculty of Health Sciences, Curtin University, Bentley, WA, Australia Purpose: The aim was to evaluate the stability of linezolid in commonly used intravenous fluids and in aqueous solution to determine the kinetics of degradation and shelf-life values at alkaline pH values. Methods: Forced degradation studies were performed on linezolid in solution to develop a validated high-performance liquid chromatography analysis. Sodium chloride 0.9%, sodium lactate, and glucose 5% and glucose 10% solution containing 2.0 mg/mL linezolid were stored at 25.0°C (±0.1°C for 34 days. The effect of temperature on the stability of linezolid in 0.1 M sodium hydroxide solution was investigated to determine the activation energy. The degradation rates of linezolid at selected pH values at 70.0°C and the influence of ionic strength were also examined. Activation energy data were applied to determine the shelf-life values at selected pH values, and a pH rate profile was constructed over the pH range of 8.7–11.4. The stability of intravenous linezolid (Zyvox® solution was evaluated by storing at 70.0°C for 72 hours. Results: Linezolid was found to maintain >95.0% of its initial concentration after storage at 25.0°C for 34 days in sodium lactate, 0.9% in sodium chloride, and 5% and 10% in glucose solutions. Linezolid was degraded at alkaline pH values by first-order kinetics. Activation energy data showed that temperature, but not ionic strength, influenced the degradation rate significantly. An activation energy of 58.22 kJ/mol was determined for linezolid in 0.1 M sodium hydroxide solution. Linezolid was least stable at high pH values and at elevated temperatures. It was determined that linezolid has adequate stability for the preparation of intravenous fluids for clinical administration. Conclusion: Linezolid was found to have a shelf life of 34 days at 25°C when added to

  19. Comparison of a Point-of-Care Glucometer and a Laboratory Autoanalyzer for Measurement of Blood Glucose Concentrations in Domestic Pigeons ( Columba livia domestica).

    Science.gov (United States)

    Mohsenzadeh, Mahdieh Sadat; Zaeemi, Mahdieh; Razmyar, Jamshid; Azizzadeh, Mohammad

    2015-09-01

    Biochemical analysis is necessary for diagnosis and monitoring of diseases in birds; however, the small volume of blood that can be safely obtained from small avian species often limits laboratory diagnostic testing. Consequently, a suitable methodology requiring only a small volume of blood must be used. This study was designed to compare blood glucose concentrations in domestic pigeons ( Columba livia domestica) as measured by a commercial, handheld, human glucometer and a standard autoanalyzer. During the first phase of the study, whole blood samples obtained from 30 domestic pigeons were used to measure the blood glucose concentration with a glucometer, the packed cell volume (PCV), and the total erythrocyte count (nRBC). Plasma separated from the each sample was then used to obtain the plasma glucose concentration with the autoanalyzer. During the second phase of the study, 30 pigeons were assigned to 2 equal groups (n = 15). Hypoglycemia or hyperglycemia was induced in each group by intravenous injection of insulin or glucose, respectively. Blood was collected and processed, and glucose concentrations, PCV, and nRBC were measured as previously described. Linear-regression models demonstrated a significant relationship between results measured by the glucometer and autoanalyzer results from normoglycemic (correlation coefficient [R] = 0.43, P = .02), hypoglycemic (R = 0.95; P < .001), and hyperglycemic (R = 0.81; P < .001) birds. The results of this study suggest that we can predict the real blood-glucose concentration of pigeons by using results obtained by a glucometer.

  20. Whole body glucose kinetics in type I diabetes studied with [6,6-2H] and [U-13C]-glucose and the artificial B-cell

    International Nuclear Information System (INIS)

    Darmaun, D.; Cirillo, D.; Koziet, J.; Chauvet, D.; Young, V.R.; Robert, J.J.

    1988-01-01

    Dynamic aspects of whole body glucose metabolism were assessed in ten young adult insulin-dependent (type I) diabetic men. Using a primed, continuous intravenous infusion of [6,6- 2 H]glucose and [U- 13 C]glucose, endogenous production, tissue uptake, carbon recycling, and oxidation of glucose were measured in the postabsorptive state. These studies were undertaken after blood glucose had been maintained overnight at 5.9 +/- 0.4 mmol/L (n = 10), and on another night at 10.5 +/- 0.4 mmol/L (n = 4) or 15.2 +/- 0.6 mmol/L (n = 6). In the normoglycemic state, endogenous glucose production averaged 2.15 +/- 0.13 mg x kg-1 x min-1. This value, as well as the rate of glucose carbon recycling (0.16 +/- 0.04 mg x kg-1 x min-1) and glucose oxidation (1.52 +/- 0.16 mg x kg-1 x min-1) are comparable to those found in nondiabetic controls. In the hyperglycemic states at 10 or 15 mmol/L, endogenous glucose production was increased by 11% (P less than .01) and 60% (P less than .01) compared to the normoglycemic states, respectively. Glucose carbon recycling contributed only a small percentage to this variation in glucose production (15% at the 15 mmol/L glucose level). This suggests that if gluconeogenesis participates in the increased glucose output, it is not dependent on a greater systemic supply of three-carbon precursors. The increased rate of glucose production in the hyperglycemic state was quantitatively offset by a rise in urinary glucose excretion. Glucose tissue uptake, as well as glucose oxidation, did not vary between normoglycemic and hyperglycemic states

  1. Analytical Parameters of an Amperometric Glucose Biosensor for Fast Analysis in Food Samples.

    Science.gov (United States)

    Artigues, Margalida; Abellà, Jordi; Colominas, Sergi

    2017-11-14

    Amperometric biosensors based on the use of glucose oxidase (GOx) are able to combine the robustness of electrochemical techniques with the specificity of biological recognition processes. However, very little information can be found in literature about the fundamental analytical parameters of these sensors. In this work, the analytical behavior of an amperometric biosensor based on the immobilization of GOx using a hydrogel (Chitosan) onto highly ordered titanium dioxide nanotube arrays (TiO₂NTAs) has been evaluated. The GOx-Chitosan/TiO₂NTAs biosensor showed a sensitivity of 5.46 μA·mM -1 with a linear range from 0.3 to 1.5 mM; its fundamental analytical parameters were studied using a commercial soft drink. The obtained results proved sufficient repeatability (RSD = 1.9%), reproducibility (RSD = 2.5%), accuracy (95-105% recovery), and robustness (RSD = 3.3%). Furthermore, no significant interferences from fructose, ascorbic acid and citric acid were obtained. In addition, the storage stability was further examined, after 30 days, the GOx-Chitosan/TiO₂NTAs biosensor retained 85% of its initial current response. Finally, the glucose content of different food samples was measured using the biosensor and compared with the respective HPLC value. In the worst scenario, a deviation smaller than 10% was obtained among the 20 samples evaluated.

  2. Semimechanistic model describing gastric emptying and glucose absorption in healthy subjects and patients with type 2 diabetes

    DEFF Research Database (Denmark)

    Alskär, Oskar; Bagger, Jonatan I; Røge, Rikke M.

    2016-01-01

    The integrated glucose-insulin (IGI) model is a previously published semimechanistic model that describes plasma glucose and insulin concentrations after glucose challenges. The aim of this work was to use knowledge of physiology to improve the IGI model's description of glucose absorption and ga...... model provides a better description and improves the understanding of dynamic glucose tests involving oral glucose....... and gastric emptying after tests with varying glucose doses. The developed model's performance was compared to empirical models. To develop our model, data from oral and intravenous glucose challenges in patients with type 2 diabetes and healthy control subjects were used together with present knowledge...... glucose absorption was superior to linear absorption regardless of the gastric emptying model applied. The semiphysiological model developed performed better than previously published empirical models and allows better understanding of the mechanisms underlying glucose absorption. In conclusion, our new...

  3. Motor function is associated with 1,25(OH)(2)D and indices of insulin-glucose dynamics in non-diabetic older adults.

    Science.gov (United States)

    Justice, Jamie N; Pierpoint, Lauren A; Mani, Diba; Schwartz, Robert S; Enoka, Roger M

    2014-06-01

    Advancing age is accompanied by changes in metabolic characteristics, such as reduced insulin sensitivity and low levels of vitamin D, which may exacerbate age-related declines in physical function. The aim of the present study was to determine the associations between insulin-glucose dynamics, vitamin D metabolites, and performance on a battery of motor tasks in healthy, non-diabetic older adults. Sixty-nine community-dwelling men and women (65-90 years) were recruited. Insulin-glucose dynamics were determined by an intravenous glucose tolerance test, and vitamin D metabolites were measured. Motor function was characterized by the time to walk 500 m, chair-rise time, lower body strength, dorsiflexor steadiness and endurance time, and muscle coactivation. Significant unadjusted correlations were found between insulin-glucose dynamics and 1,25-dihydroxyvitamin D [1,25(OH)2D] with walk time, strength, steadiness, endurance time, and muscle activation (p glucose (R (2) = 0.55, p glucose dynamics and the bio-active vitamin D metabolite 1,25(OH)2D. Walking endurance and strength were explained by 1,25(OH)2D and fasting blood glucose and insulin, even after adjusting for age, sex, and body fat. Motor function in a relatively small sample of non-diabetic older men and women was associated with metabolic factors that increase in prevalence with aging.

  4. Effect of glucocorticoid therapy upon glucose metabolism in COPD patients with acute exacerbation

    International Nuclear Information System (INIS)

    Wu Sihai; Wei Zhenggan; Huang Ming'an; Yao Jianguo; Li Hongsheng

    2002-01-01

    Objective: To study the effect of glucocorticoids therapy upon glucose metabolism in COPD patients with acute exacerbation. Methods: Plasma glucose and insulin levels in COPD patients after intravenous administration of 10 mg dexamethasone daily for 5 days were determined oral with glucose tolerance test (OGTT) and insulin release test (IRT). Results: 1) The levels of basal plasma glucose and insulin were significantly higher in severe hypoxemic group than those in moderate hypoxemic group (p 2 (r = -0.5242, p < 0.05). 2) The levels of plasma glucose in intermediate and severe hypoxemic groups were remarkable higher (p < 0.05) than those in mild group. The two peak times of glucose curve were observed at one and two hour after oral glucose load. 3) After the administration of glucocorticoids, at half an hour and one hour plasma glucose levels were significantly higher than those before, the peak time of glucose levels appeared earlier and the insulin release levels were higher than they were before therapy (p < 0.05). Conclusion: COPD patients with acute exacerbation complicated with hypoxemia had problems of impaired glucose tolerance. The administration of glucocorticoids made the impairment worse

  5. Time course of radiolabeled 2-deoxy-D-glucose 6-phosphate turnover in cerebral cortex of goats

    International Nuclear Information System (INIS)

    Pelligrino, D.A.; Miletich, D.J.; Albrecht, R.F.

    1987-01-01

    The vivo dephosphorylation rate of 2-deoxy-D-glucose 6-phosphate (DGP) in the cerebral cortex of goats injected intravenously with radiolabeled 2-deoxy-D-glucose (DG) was investigated. Serial rapidly frozen samples of parietal cortical gray tissue were obtained at regular intervals over time periods from 45 min to 3 h in awake goats or in paralyzed and artificially ventilated goats maintained under 70% N 2 O or pentobarbital sodium anesthesia. The samples were analyzed for glucose content and separate DG and DGP activities. The rate parameters for phosphorylation (k/sup */ 4 ) and dephosphorylation (k/sup */ 4 ) were estimated in each animal. The glucose phosphorylation rate (PR) was calculated over the intervals 3-5 (or 6), 3-10, 3-20, 3-30, and 3-45 min, assuming k/sup */ 4 = O. As the evaluation period was extended beyond 10 min, the calculated PR became increasingly less when compared with that calculated over the 3- to 5- (or 6) min interval (PR/sub i/). Furthermore, as metabolic activity decreased, the magnitude of the error increased such that at 45 min pentobarbital-anesthetize goats underestimated the PR/sub i/ by 46.5% compared with only 23.1 in N 2 O-anesthetized goats. This was also reflected in the >twofold higher k/sup */ 4 /k/sup */ 3 ratio in the pentobarbital vs. N 2 O-anesthetized group. It is concluded that when using the DG method in the goat, DGP dephosphorylation cannot be ignored when employing >10-min evaluation periods

  6. Glucose-lowering effect of BTS 67 582.

    Science.gov (United States)

    Page, T; Bailey, C J

    1997-12-01

    1. The hypoglycaemic effect of BTS 67 582 (1,1-dimethyl-2(2-morpholinophenyl) guanidine fumarate) was studied in normal rats. 2. BTS 67 582 (100 mg kg(-1), p.o.) acutely lowered basal plasma glucose concentrations: onset within 1 h, maximum decrease of >40% at 2-3 h, and partial return to euglycaemia by 5 h. Plasma insulin concentrations were increased: onset within 30 min, maximum increase 3 fold at 1-2 h; returning to normal by 5 h. 3. BTS 67 582 (100 mg kg(-1)) increased (by 56%) the rate of disappearance of plasma glucose during an intravenous glucose tolerance test, accompanied by a 51% increase in insulin concentrations. 4. During hyperglycaemic clamp studies BTS 67 582 (100 mg kg(-1)) increased glucose utilization 3 fold. This was associated with a 3 fold increase in insulin concentrations, even in the presence of adrenaline at a dosage which inhibits glucose-induced insulin release. 5. When the insulin-releasing effect of BTS 67 582 (100 mg kg(-1)) was inhibited by infusion of somatostatin, there was no effect on glycaemia. 6. Insulin-dependent diabetic BB/S rats, which do not produce endogenous insulin, showed no effect of BTS 67 582 (100 mg kg(-1)) on plasma glucose concentrations in the presence or absence of exogenous insulin. 7. The results demonstrate an acute hypoglycaemic effect of BTS 67 582 which appears to result mainly from its potent insulin-releasing action.

  7. Involvement of glucagon-like peptide-1 in the glucose-lowering effect of metformin

    DEFF Research Database (Denmark)

    Bahne, Emilie; Hansen, Morten; Brønden, Andreas

    2016-01-01

    Metformin is an oral antihyperglycaemic drug used in the first-line treatment of type 2 diabetes. Metformin's classic and most well-known blood glucose-lowering mechanisms include reduction of hepatic gluconeogenesis and increased peripheral insulin sensitivity. Interestingly, intravenously...... administered metformin is ineffective and recently, metformin was shown to increase plasma concentrations of the glucose-lowering gut incretin hormone glucagon-like peptide-1 (GLP-1), which may contribute to metformin's glucose-lowering effect in patients with type 2 diabetes. The mechanisms behind metformin......-induced increments in GLP-1 levels remain unknown, but it has been hypothesized that metformin stimulates GLP-1 secretion directly and/or indirectly and that metformin prolongs the half-life of GLP-1. Also, it has been suggested that metformin may potentiate the glucose-lowering effects of GLP-1 by increasing target...

  8. Ratiometric glucose sensing based on fluorescent oxygen films and glucose oxidase

    Directory of Open Access Journals (Sweden)

    Fengyu Su

    2017-06-01

    Full Text Available A new two-layer sensor film was constructed for sensing glucose based on glucose oxidase and oxygen sensing material. The first layer of film containing the oxygen sensor and intra-reference material was polymerized, then the second layer of glucose oxidase and glutaraldehyde was formed on the oxygen sensor layer. The two-layer sensor film has a resolution up to 0.05 mM and a detection range from 0 to 5 mM to glucose. The effects of pH and temperature on the sensing performance were systematically investigated. The selective detection of glucose among other monosaccharides, such as fructose, mannose and galactose indicated that the sensing film has excellent selectivity. The prepared sensor was successfully applied for glucose sample detection of glucose concentration in artificial tears. Keywords: Glucose sensor, Glucose oxidase, Fluorescence, Oxygen film, Diabetes

  9. Impact of partial pressure of oxygen in blood samples on the performance of systems for self-monitoring of blood glucose.

    Science.gov (United States)

    Schmid, Christina; Baumstark, Annette; Pleus, Stefan; Haug, Cornelia; Tesar, Martina; Freckmann, Guido

    2014-03-01

    The partial pressure of oxygen (pO2) in blood samples can affect glucose measurements with oxygen-sensitive systems. In this study, we assessed the influence of different pO2 levels on blood glucose (BG) measurements with five glucose oxidase (GOD) systems and one glucose dehydrogenase (GDH) system. All selected GOD systems were indicated by the manufacturers to be sensitive to increased oxygen content of the blood sample. Venous blood samples of 16 subjects (eight women, eight men; mean age, 52 years; three with type 1 diabetes, four with type 2 diabetes, and nine without diabetes) were collected. Aliquots of each sample were adjusted to the following pO2 values: ≤45 mm Hg, approximately 70 mm Hg, and ≥150 mm Hg. For each system, five consecutive measurements on each sample were performed using the same test strip lot. Relative differences between the mean BG value at a pO2 level of approximately 70 mm Hg, which was considered to be similar to pO2 values in capillary blood samples, and the mean BG value at pO2 levels ≤45 mm Hg and ≥150 mm Hg were calculated. The GOD systems showed mean relative differences between 11.8% and 44.5% at pO2 values ≤45 mm Hg and between -14.6% and -21.2% at pO2 values ≥150 mm Hg. For the GDH system, the mean relative differences were -0.3% and -0.2% at pO2 values ≤45 mm Hg and ≥150 mm Hg, respectively. The magnitude of the pO2 impact on BG measurements seems to vary among the tested oxygen-sensitive GOD systems. The pO2 range in which oxygen-sensitive systems operate well should be provided in the product information.

  10. Effect of repeated application of 14C-carbaryl and of addition of glucose and cellulose to soil samples

    International Nuclear Information System (INIS)

    Hirata, R.; Luchini, L.C.; Mesquita, T.B.; Ruegg, E.F.

    1984-01-01

    The behaviour of the insecticide carbaryl is studied in samples of Gley Humic and Red-Yellow Latosol soil by means of radiometric techniques. In the Red-Yellow Latosol two carbon sources - glucose and cellulose - and a mixture of glucose plus cellulose were added. Repeated applications of carbaryl in both soils highly increased the rate of degradation, probably due to a rapid increase in the number of microorganisms by using the pesticide as substrate. (M.A.C.) [pt

  11. Central effects of beta-endorphins on glucose homeostasis in the conscious dog

    International Nuclear Information System (INIS)

    Radosevich, P.M.; Lacy, D.B.; Brown, L.L.; Williams, P.E.; Abumrad, N.N.

    1989-01-01

    The effects of centrally administered beta-endorphins on glucose homeostasis in the conscious dog were studied. Intracerebroventricular administration of beta-endorphin (0.2 mg/h) caused a 70% increase in plasma glucose. The mechanism of the hyperglycemia was twofold: there was an early increase in glucose production and a late inhibition of glucose clearance. These changes are explained by marked increases in plasma epinephrine (30-fold) and norepinephrine (6-fold) that occurred during infusion of beta-endorphin. Central administration of beta-endorphin also resulted in increased levels of adrenocorticotropic hormone and cortisol. In addition there was an increase in plasma insulin but no increase in plasma glucagon. Intravenous administration of beta-endorphin did not alter glucose homeostasis. Intracerebroventricular administration of acetylated beta-endorphin did not perturb glucose kinetics or any of the hormones that changed during infusion of the unacetylated peptide. We conclude that beta-endorphin acts centrally to cause hyperglycemia by stimulating sympathetic outflow and the pituitary-adrenal axis. Acetylation of beta-endorphin abolishes the in vivo activity of the peptide

  12. Central effects of beta-endorphins on glucose homeostasis in the conscious dog

    Energy Technology Data Exchange (ETDEWEB)

    Radosevich, P.M.; Lacy, D.B.; Brown, L.L.; Williams, P.E.; Abumrad, N.N.

    1989-02-01

    The effects of centrally administered beta-endorphins on glucose homeostasis in the conscious dog were studied. Intracerebroventricular administration of beta-endorphin (0.2 mg/h) caused a 70% increase in plasma glucose. The mechanism of the hyperglycemia was twofold: there was an early increase in glucose production and a late inhibition of glucose clearance. These changes are explained by marked increases in plasma epinephrine (30-fold) and norepinephrine (6-fold) that occurred during infusion of beta-endorphin. Central administration of beta-endorphin also resulted in increased levels of adrenocorticotropic hormone and cortisol. In addition there was an increase in plasma insulin but no increase in plasma glucagon. Intravenous administration of beta-endorphin did not alter glucose homeostasis. Intracerebroventricular administration of acetylated beta-endorphin did not perturb glucose kinetics or any of the hormones that changed during infusion of the unacetylated peptide. We conclude that beta-endorphin acts centrally to cause hyperglycemia by stimulating sympathetic outflow and the pituitary-adrenal axis. Acetylation of beta-endorphin abolishes the in vivo activity of the peptide.

  13. The response of the pituitary-adrenal and pituitary-thyroidal axes to the plasma glucose perturbations in Babesia canis rossi babesiosis

    Directory of Open Access Journals (Sweden)

    J.P. Schoeman

    2007-06-01

    Full Text Available This prospective, cross-sectional, interventional study was designed to determine the association between the hormones of the pituitary-adrenal and pituitary-thyroid axes and other clinical parameters with the blood glucose perturbations in dogs with naturally occurring Babesia canis rossi babesiosis. Thirty-six dogs with canine babesiosis were studied. Blood samples were obtained from the jugular vein in each dog prior to treatment at admission to hospital and serum endogenous adrenocorticotrophic hormone(ACTH, pre-ACTH cortisol, thyroxine, free thyroxine and TSH concentrations were measured. Immediately thereafter each dog was injected intravenously with 5 µg/kg of ACTH (tetracosactrin. A 2nd blood sample was taken 1 hour later for serumpost-ACTHcortisol measurement. Three patient groups were recruited: hypoglycaemic dogs (glucose 5.5 mmol/ℓ, n = 12. Basal and post-ACTH serum cortisol concentrations were significantly higher in hypoglycaemic dogs, whereas body temperature, serum thyroxine and free thyroxine were significantly lower in hypoglycaemic dogs. Haematocrit was significantly lower in both hypo-and hyperglycaemic dogs compared with normoglycaemic dogs. Low blood glucose concentrations were significantly associated with high basal and post-ACTH cortisol concentrations and with low serum thyroxine and free thyroxine concentrations in dogs suffering from B. canis rossi babesiosis.

  14. Caffeic acid as active principle from the fruit of Xanthium strumarium to lower plasma glucose in diabetic rats.

    Science.gov (United States)

    Hsu, F L; Chen, Y C; Cheng, J T

    2000-04-01

    The antihyperglycemic effect of caffeic acid, one of the phenolic compounds contained in the fruit of Xanthium strumarium, was investigated. After an intravenous injection of caffeic acid into diabetic rats of both streptozotocin-induced and insulin-resistant models, a dose-dependent decrease of plasma glucose was observed. However, a similar effect was not produced in normal rats. An insulin-independent action of caffeic acid can thus be considered. Otherwise, this compound reduced the elevation of plasma glucose level in insulin-resistant rats receiving a glucose challenge test. Also, glucose uptake into the isolated adipocytes was raised by caffeic acid in a concentration-dependent manner. Increase of glucose utilization by caffeic acid seems to be responsible for the lowering of plasma glucose.

  15. Actions of prolonged ghrelin infusion on gastrointestinal transit and glucose homeostasis in humans

    DEFF Research Database (Denmark)

    Falkén, Y; Hellström, P M; Sanger, G J

    2010-01-01

    Ghrelin is produced by enteroendocrine cells in the gastric mucosa and stimulates gastric emptying in healthy volunteers and patients with gastroparesis in short-term studies. The aim of this study was to evaluate effects of intravenous ghrelin on gastrointestinal motility and glucose homeostasis...... during a 6-h infusion in humans....

  16. Intravenous/oral ciprofloxacin therapy versus intravenous ceftazidime therapy for selected bacterial infections.

    Science.gov (United States)

    Gaut, P L; Carron, W C; Ching, W T; Meyer, R D

    1989-11-30

    The efficacy and toxicity of sequential intravenous and oral ciprofloxacin therapy was compared with intravenously administered ceftazidime in a prospective, randomized, controlled, non-blinded trial. Thirty-two patients (16 patients receiving ciprofloxacin and 16 patients receiving ceftazidime) with 38 infections caused by susceptible Pseudomonas aeruginosa, enteric gram-negative rods, Salmonella group B, Serratia marcescens, Pseudomonas cepacia, and Xanthomonas maltophilia at various sites were evaluable for determination of efficacy. Length of therapy varied from seven to 25 days. Concomitant antimicrobials included intravenously administered beta-lactams for gram-positive organisms, intravenous/oral metronidazole and clindamycin for anaerobes, and intravenous/local amphotericin B for Candida albicans. Intravenous administration of 200 mg ciprofloxacin every 12 hours to 11 patients produced peak serum levels between 1.15 and 3.12 micrograms/ml; trough levels ranged between 0.08 and 0.86 micrograms/ml. Overall response rates were similar for patients receiving ciprofloxacin and ceftazidime. Emergence of resistance was similar in both groups--one Enterobacter cloacae and two P. aeruginosa became resistant after ciprofloxacin therapy and two P. aeruginosa became resistant after ceftazidime therapy. The frequency of superinfection with a variety of organisms was also similar in both groups. Adverse events related to ciprofloxacin included transient pruritus at the infusion site and generalized rash leading to drug discontinuation (one patient each), and with ceftazidime adverse effects included pain at the site of infusion and the development of allergic interstitial nephritis (one patient each). Overall, intravenous/oral ciprofloxin therapy appears to be as safe and effective as intravenous ceftazidime therapy in the treatment of a variety of infections due to susceptible aerobic gram-negative organisms.

  17. [Hypoglycaemic coma due to falsely elevated glucose values in a patient with diabetes mellitus and peritoneal dialysis].

    Science.gov (United States)

    Nienhuis, W A; Bruijns, R H J; Vastenburg, G; Wouters, R S M E

    2006-07-15

    A 45-year-old female diabetes-mellitus patient on peritoneal dialysis was admitted because of vertigo. During her stay in hospital she developed a comatose condition with abnormal head posture and deviation ofthe eyes to the left. Capillary blood from the fingertip showed a glucose value of 15.4 mmol/l. However, the automatically obtained glucose value delivered with a blood-gas analysis was found to be 1.2 mmol/l. The neurological state of the patient normalised fully after intravenous glucose administration. The glucose values were falsely elevated because the patient used a peritoneal dialysis fluid at night which contained icodextrin as an osmotic agent. Metabolites of icodextrin can influence blood-glucose measurements taken using analyzers that depend on the enzyme glucose dehydrogenase. To prevent potentially life-threatening situations, the use of an adequate glucose meter is of paramount importance.

  18. Analytical Parameters of an Amperometric Glucose Biosensor for Fast Analysis in Food Samples

    Directory of Open Access Journals (Sweden)

    Margalida Artigues

    2017-11-01

    Full Text Available Amperometric biosensors based on the use of glucose oxidase (GOx are able to combine the robustness of electrochemical techniques with the specificity of biological recognition processes. However, very little information can be found in literature about the fundamental analytical parameters of these sensors. In this work, the analytical behavior of an amperometric biosensor based on the immobilization of GOx using a hydrogel (Chitosan onto highly ordered titanium dioxide nanotube arrays (TiO2NTAs has been evaluated. The GOx–Chitosan/TiO2NTAs biosensor showed a sensitivity of 5.46 μA·mM−1 with a linear range from 0.3 to 1.5 mM; its fundamental analytical parameters were studied using a commercial soft drink. The obtained results proved sufficient repeatability (RSD = 1.9%, reproducibility (RSD = 2.5%, accuracy (95–105% recovery, and robustness (RSD = 3.3%. Furthermore, no significant interferences from fructose, ascorbic acid and citric acid were obtained. In addition, the storage stability was further examined, after 30 days, the GOx–Chitosan/TiO2NTAs biosensor retained 85% of its initial current response. Finally, the glucose content of different food samples was measured using the biosensor and compared with the respective HPLC value. In the worst scenario, a deviation smaller than 10% was obtained among the 20 samples evaluated.

  19. Analytical Parameters of an Amperometric Glucose Biosensor for Fast Analysis in Food Samples

    Science.gov (United States)

    2017-01-01

    Amperometric biosensors based on the use of glucose oxidase (GOx) are able to combine the robustness of electrochemical techniques with the specificity of biological recognition processes. However, very little information can be found in literature about the fundamental analytical parameters of these sensors. In this work, the analytical behavior of an amperometric biosensor based on the immobilization of GOx using a hydrogel (Chitosan) onto highly ordered titanium dioxide nanotube arrays (TiO2NTAs) has been evaluated. The GOx–Chitosan/TiO2NTAs biosensor showed a sensitivity of 5.46 μA·mM−1 with a linear range from 0.3 to 1.5 mM; its fundamental analytical parameters were studied using a commercial soft drink. The obtained results proved sufficient repeatability (RSD = 1.9%), reproducibility (RSD = 2.5%), accuracy (95–105% recovery), and robustness (RSD = 3.3%). Furthermore, no significant interferences from fructose, ascorbic acid and citric acid were obtained. In addition, the storage stability was further examined, after 30 days, the GOx–Chitosan/TiO2NTAs biosensor retained 85% of its initial current response. Finally, the glucose content of different food samples was measured using the biosensor and compared with the respective HPLC value. In the worst scenario, a deviation smaller than 10% was obtained among the 20 samples evaluated. PMID:29135931

  20. Stimulation of the endogenous incretin glucose-dependent insulinotropic peptide by enteral dextrose improves glucose homeostasis and inflammation in murine endotoxemia.

    Science.gov (United States)

    Shah, Faraaz Ali; Singamsetty, Srikanth; Guo, Lanping; Chuan, Byron W; McDonald, Sherie; Cooper, Bryce A; O'Donnell, Brett J; Stefanovski, Darko; Wice, Burton; Zhang, Yingze; O'Donnell, Christopher P; McVerry, Bryan J

    2018-03-01

    Loss of glucose homeostasis during sepsis is associated with increased organ dysfunction and higher mortality. Novel therapeutic strategies to promote euglycemia in sepsis are needed. We have previously shown that early low-level intravenous (IV) dextrose suppresses pancreatic insulin secretion and induces insulin resistance in septic mice, resulting in profound hyperglycemia and worsened systemic inflammation. In this study, we hypothesized that administration of low-level dextrose via the enteral route would stimulate intestinal incretin hormone production, potentiate insulin secretion in a glucose-dependent manner, and thereby improve glycemic control in the acute phase of sepsis. We administered IV or enteral dextrose to 10-week-old male C57BL/6J mice exposed to bacterial endotoxin and measured incretin hormone release, glucose disposal, and proinflammatory cytokine production. Compared with IV administration, enteral dextrose increased circulating levels of the incretin hormone glucose-dependent insulinotropic peptide (GIP) associated with increased insulin release and insulin sensitivity, improved mean arterial pressure, and decreased proinflammatory cytokines in endotoxemic mice. Exogenous GIP rescued glucose metabolism, improved blood pressure, and increased insulin release in endotoxemic mice receiving IV dextrose, whereas pharmacologic inhibition of GIP signaling abrogated the beneficial effects of enteral dextrose. Thus, stimulation of endogenous GIP secretion by early enteral dextrose maintains glucose homeostasis and attenuates the systemic inflammatory response in endotoxemic mice and may provide a therapeutic target for improving glycemic control and clinical outcomes in patients with sepsis. Published by Elsevier Inc.

  1. Effects of intravenous glucose on Dopaminergic function in the human brain in vivo

    NARCIS (Netherlands)

    Haltia, Lauri T.; Rinne, Juha O.; Merisaari, Harri; Maguire, Ralph P.; Savontaus, Eriika; Helin, Semi; Nagren, Kjell; Kaasinen, Valtteri

    Dopamine is known to regulate food intake by modulating food reward via the mesolimbic circuitry of the brain. The objective of this study was to compare the effects of high energy input (i.v. glucose) on striatal and thalamic dopamine release in overweight and lean individuals. We hypothesized that

  2. Ex vivo changes in blood glucose levels seldom change blood glucose control algorithm recommendations

    NARCIS (Netherlands)

    de Groene, L.; Harmsen, R. E.; Binnekade, J. M.; Spronk, P. E.; Schultz, M. J.

    2010-01-01

    Background. Hyperglycemia and glycemic variabilities are associated with adverse outcomes in critically ill patients. Blood glucose control with insulin mandates an adequate and precise assessment of blood glucose levels. Blood glucose levels, however, can change ex vivo after sampling. The aim of

  3. Interrelations between glucose-induced insulin response, metabolic indicators, and time of first ovulation in high-yielding dairy cows.

    Science.gov (United States)

    Bossaert, P; Leroy, J L M R; De Vliegher, S; Opsomer, G

    2008-09-01

    High-yielding dairy cows are more susceptible to metabolic and reproductive disorders than low-yielding cows. Insulin plays a pivotal role in the development of both problems. In the present study, we aimed to assess the glucose-induced insulin responses of dairy cows at different time points relative to calving and to relate this to the metabolic status and the time of first ovulation. Twenty-three healthy, multiparous Holstein-Friesian cows with a high genetic merit for milk yield were studied from 14 d prepartum to 42 d postpartum. Intravenous glucose tolerance tests were performed on -14, 14, and 42 d relative to calving to evaluate the plasma insulin and glucose responses to a glucose load, as estimated by the peak concentration, the area under the curve (AUC), and the clearance rates of insulin and glucose. Blood samples were obtained at 3-d intervals and analyzed for glucose, insulin, and nonesterified fatty acids (NEFA). The time of first ovulation was defined by transrectal ultrasonography and plasma progesterone analysis. Glucose-induced insulin AUC and peak concentration decreased and glucose clearance increased during lactation compared with the dry period. Plasma NEFA concentrations were negatively related to insulin AUC and peak concentrations. Fourteen cows ovulated within 42 d postpartum, and the remaining 9 cows suffered from delayed resumption of ovarian function. Survival analysis demonstrated that cows with lower NEFA concentrations during the dry period tended to have earlier resumption of ovarian activity. In conclusion, our data suggest a decreased plasma insulin response to glucose postpartum in high-yielding dairy cows, possibly contributing to metabolic stress during the early postpartum period. It is hypothesized that NEFA impair glucose-induced insulin secretion in dairy cows. Additionally, our results suggest the importance of lipolysis during the transition period as a risk factor for delayed ovulation.

  4. Glucose turnover, oxidation, and indices of recycling in severely traumatized patients

    Energy Technology Data Exchange (ETDEWEB)

    Jeevanandam, M.; Young, D.H.; Schiller, W.R. (St. Joseph' s Hospital Medical Center, Phoenix, AZ (USA))

    1990-05-01

    Hyperglycemia is often seen in trauma patients and its etiology is not clearly understood. We have determined parameters of glucose metabolism by using simultaneous primed-constant intravenous infusion of both (6-3H) glucose and (U-14C) glucose in ten severely traumatized hypermetabolic subjects during the early flow phase of injury and in six post-absorptive normal volunteers. The mean rate of glucose production (determined by means of (6-3H) glucose) was 3.96 +/- 0.40 mg/kg/min in trauma patients, which was significantly (p = 0.025) higher than the value of 2.75 +/- 0.13 observed in normal volunteers. Glucose turnover rates determined with (U-14C) glucose as tracer were lower in all subjects. The difference between the turnover rates determined by the two tracers represents an index of recycling of glucose through three-carbon fragments. This recycling index was similar in both groups of subjects in amount (0.24 +/- 0.07 vs. 0.26 +/- 0.08 mg glucose/kg/min) but different when expressed as percentage of total glucose turnover (5.6 +/- 1.4% vs. 9.8 +/- 1.7%; p = 0.05). The absolute rates of glucose clearance, oxidation, and recycling were similar in stressed trauma patients and unstressed controls although the rate of production was increased by 44% due to injury. Post-trauma hyperglycemia was mainly due to an increased hepatic output of glucose and not due to a decreased ability of the tissue to extract glucose from the plasma. Hyperglycemia may be the driving force in the metabolic effects of injury.

  5. Glucose turnover, oxidation, and indices of recycling in severely traumatized patients

    International Nuclear Information System (INIS)

    Jeevanandam, M.; Young, D.H.; Schiller, W.R.

    1990-01-01

    Hyperglycemia is often seen in trauma patients and its etiology is not clearly understood. We have determined parameters of glucose metabolism by using simultaneous primed-constant intravenous infusion of both [6-3H] glucose and [U-14C] glucose in ten severely traumatized hypermetabolic subjects during the early flow phase of injury and in six post-absorptive normal volunteers. The mean rate of glucose production (determined by means of [6-3H] glucose) was 3.96 +/- 0.40 mg/kg/min in trauma patients, which was significantly (p = 0.025) higher than the value of 2.75 +/- 0.13 observed in normal volunteers. Glucose turnover rates determined with [U-14C] glucose as tracer were lower in all subjects. The difference between the turnover rates determined by the two tracers represents an index of recycling of glucose through three-carbon fragments. This recycling index was similar in both groups of subjects in amount (0.24 +/- 0.07 vs. 0.26 +/- 0.08 mg glucose/kg/min) but different when expressed as percentage of total glucose turnover (5.6 +/- 1.4% vs. 9.8 +/- 1.7%; p = 0.05). The absolute rates of glucose clearance, oxidation, and recycling were similar in stressed trauma patients and unstressed controls although the rate of production was increased by 44% due to injury. Post-trauma hyperglycemia was mainly due to an increased hepatic output of glucose and not due to a decreased ability of the tissue to extract glucose from the plasma. Hyperglycemia may be the driving force in the metabolic effects of injury

  6. Evaluation of postprandial glucose excursion using a novel minimally invasive glucose area-under-the-curve monitoring system.

    Science.gov (United States)

    Kuranuki, Sachi; Sato, Toshiyuki; Okada, Seiki; Hosoya, Samiko; Seko, Akinobu; Sugihara, Kaya; Nakamura, Teiji

    2013-01-01

    To develop a minimally invasive interstitial fluid extraction technology (MIET) to monitor postprandial glucose area under the curve (AUC) without blood sampling, we evaluated the accuracy of glucose AUC measured by MIET and compared with that by blood sampling after food intake. Interstitial fluid glucose AUC (IG-AUC) following consumption of 6 different types of foods was measured by MIET. MIET consisted of stamping microneedle arrays, placing hydrogel patches on the areas, and calculating IG-AUC based on glucose levels in the hydrogels. Glycemic index (GI) was determined using IG-AUC and reference AUC measured by blood sampling. IG-AUC strongly correlated with reference AUC (R = 0.91), and GI determined using IG-AUC showed good correlation with that determined by reference AUC (R = 0.88). IG-AUC obtained by MIET can accurately predict the postprandial glucose excursion without blood sampling. In addition, feasibility of GI measurement by MIET was confirmed.

  7. Adrenergic blockade does not abolish elevated glucose turnover during bacterial infection

    International Nuclear Information System (INIS)

    Hargrove, D.M.; Bagby, G.J.; Lang, C.H.; Spitzer, J.J.

    1988-01-01

    Infusions of adrenergic antagonists were used to investigate the role of catecholamines in infection-induced elevations of glucose kinetics. Infection was produced in conscious catheterized rats by repeated subcutaneous injections of live Escherichia coli over 24 h. Glucose kinetics were measured by the constant intravenous infusion of [6- 3 H]- and [U- 14 C]glucose. Compared with noninfected rats, infected animals were hyperthermic and showed increased rates of glucose appearance, clearance, and recycling as well as mild hyperlacticacidemia. Plasma catecholamine concentrations were increased by 50-70% in the infected rats, but there were no differences in plasma glucagon, corticosterone, and insulin levels. Adrenergic blockade was produced by primed constant infusion of both propranolol (β-blocker) and phentolamine (α-blocker). A 2-h administration of adrenergic antagonists did not attenuate the elevated glucose kinetics or plasma lactate concentration in the infected rats, although it abolished the hyperthermia. In a second experiment, animals were infused with propranolol and phentolamine beginning 1 h before the first injection of E. coli and throughout the course of infection. Continuous adrenergic blockade failed to attenuate infection-induced elevations in glucose kinetics and plasma lactate. These results indicate that the adrenergic system does not mediate the elevated glucose metabolism observed in this mild model of infection

  8. Glucose feeds the TCA cycle via circulating lactate.

    Science.gov (United States)

    Hui, Sheng; Ghergurovich, Jonathan M; Morscher, Raphael J; Jang, Cholsoon; Teng, Xin; Lu, Wenyun; Esparza, Lourdes A; Reya, Tannishtha; Le Zhan; Yanxiang Guo, Jessie; White, Eileen; Rabinowitz, Joshua D

    2017-11-02

    Mammalian tissues are fuelled by circulating nutrients, including glucose, amino acids, and various intermediary metabolites. Under aerobic conditions, glucose is generally assumed to be burned fully by tissues via the tricarboxylic acid cycle (TCA cycle) to carbon dioxide. Alternatively, glucose can be catabolized anaerobically via glycolysis to lactate, which is itself also a potential nutrient for tissues and tumours. The quantitative relevance of circulating lactate or other metabolic intermediates as fuels remains unclear. Here we systematically examine the fluxes of circulating metabolites in mice, and find that lactate can be a primary source of carbon for the TCA cycle and thus of energy. Intravenous infusions of 13 C-labelled nutrients reveal that, on a molar basis, the circulatory turnover flux of lactate is the highest of all metabolites and exceeds that of glucose by 1.1-fold in fed mice and 2.5-fold in fasting mice; lactate is made primarily from glucose but also from other sources. In both fed and fasted mice, 13 C-lactate extensively labels TCA cycle intermediates in all tissues. Quantitative analysis reveals that during the fasted state, the contribution of glucose to tissue TCA metabolism is primarily indirect (via circulating lactate) in all tissues except the brain. In genetically engineered lung and pancreatic cancer tumours in fasted mice, the contribution of circulating lactate to TCA cycle intermediates exceeds that of glucose, with glutamine making a larger contribution than lactate in pancreatic cancer. Thus, glycolysis and the TCA cycle are uncoupled at the level of lactate, which is a primary circulating TCA substrate in most tissues and tumours.

  9. Influence of ketamine on regional brain glucose use

    International Nuclear Information System (INIS)

    Davis, D.W.; Mans, A.M.; Biebuyck, J.F.; Hawkins, R.A.

    1988-01-01

    The purpose of this study was to determine the effect of different doses of ketamine on cerebral function at the level of individual brain structures as reflected by glucose use. Rats received either 5 or 30 mg/kg ketamine intravenously as a loading dose, followed by an infusion to maintain a steady-state level of the drug. An additional group received 30 mg/kg as a single injection only, and was studied 20 min later, by which time they were recovering consciousness (withdrawal group). Regional brain energy metabolism was evaluated with [6- 14 C]glucose and quantitative autoradiography during a 5-min experimental period. A subhypnotic, steady-state dose (5 mg/kg) of ketamine caused a stimulation of glucose use in most brain areas, with an average increase of 20%. At the larger steady-state dose (30 mg/kg, which is sufficient to cause anesthesia), there was no significant effect on most brain regions; some sensory nuclei were depressed (inferior colliculus, -29%; cerebellar dentate nucleus, -18%; vestibular nucleus, -16%), but glucose use in the ventral posterior hippocampus was increased by 33%. In contrast, during withdrawal from a 30-mg/kg bolus, there was a stimulation of glucose use throughout the brain (21-78%), at a time when plasma ketamine levels were similar to the levels in the 5 mg/kg group. At each steady-state dose, as well as during withdrawal, ketamine caused a notable stimulation of glucose use by the hippocampus

  10. Evaluation of Postprandial Glucose Excursion Using a Novel Minimally Invasive Glucose Area-Under-the-Curve Monitoring System

    Directory of Open Access Journals (Sweden)

    Sachi Kuranuki

    2013-01-01

    Full Text Available Objective: To develop a minimally invasive interstitial fluid extraction technology (MIET to monitor postprandial glucose area under the curve (AUC without blood sampling, we evaluated the accuracy of glucose AUC measured by MIET and compared with that by blood sampling after food intake. Methods: Interstitial fluid glucose AUC (IG-AUC following consumption of 6 different types of foods was measured by MIET. MIET consisted of stamping microneedle arrays, placing hydrogel patches on the areas, and calculating IG-AUC based on glucose levels in the hydrogels. Glycemic index (GI was determined using IG-AUC and reference AUC measured by blood sampling. Results: IG-AUC strongly correlated with reference AUC (R = 0.91, and GI determined using IG-AUC showed good correlation with that determined by reference AUC (R = 0.88. Conclusions: IG-AUC obtained by MIET can accurately predict the postprandial glucose excursion without blood sampling. In addition, feasibility of GI measurement by MIET was confirmed.

  11. Dichloroacetate effects on glucose and lactate oxidation by neurons and astroglia in vitro and on glucose utilization by brain in vivo.

    Science.gov (United States)

    Itoh, Yoshiaki; Esaki, Takanori; Shimoji, Kazuaki; Cook, Michelle; Law, Mona J; Kaufman, Elaine; Sokoloff, Louis

    2003-04-15

    Neuronal cultures in vitro readily oxidized both D-[(14)C]glucose and l-[(14)C]lactate to (14)CO(2), whereas astroglial cultures oxidized both substrates sparingly and metabolized glucose predominantly to lactate and released it into the medium. [(14)C]Glucose oxidation to (14)CO(2) varied inversely with unlabeled lactate concentration in the medium, particularly in neurons, and increased progressively with decreasing lactate concentration. Adding unlabeled glucose to the medium inhibited [(14)C]lactate oxidation to (14)CO(2) only in astroglia but not in neurons, indicating a kinetic preference in neurons for oxidation of extracellular lactate over intracellular pyruvatelactate produced by glycolysis. Protein kinase-catalyzed phosphorylation inactivates pyruvate dehydrogenase (PDH), which regulates pyruvate entry into the tricarboxylic acid cycle. Dichloroacetate inhibits this kinase, thus enhancing PDH activity. In vitro dichloroacetate stimulated glucose and lactate oxidation to CO(2) and reduced lactate release mainly in astroglia, indicating that limitations in glucose and lactate oxidation by astroglia may be due to a greater balance of PDH toward the inactive form. To assess the significance of astroglial export of lactate to neurons in vivo, we attempted to diminish this traffic in rats by administering dichloroacetate (50 mgkg) intravenously to stimulate astroglial lactate oxidation and then examined the effects on baseline and functionally activated local cerebral glucose utilization (lCMR(glc)). Dichloroacetate raised baseline lCMR(glc) throughout the brain and decreased the percent increases in lCMR(glc) evoked by functional activation. These studies provide evidence in support of the compartmentalization of glucose metabolism between astroglia and neurons but indicate that the compartmentalization may be neither complete nor entirely obligatory.

  12. Fluorometric determination of free glucose and glucose 6-phosphate in cows' milk and other opaque matrices

    DEFF Research Database (Denmark)

    Larsen, Torben

    2015-01-01

    Analyses of free glucose and glucose 6-phosphate in milk have until now been dependent upon several time consuming and troublesome procedures. This has limited investigations in the area. The present article presents a new, reliable, analytical procedure, based on enzymatic degradation and fluoro......Analyses of free glucose and glucose 6-phosphate in milk have until now been dependent upon several time consuming and troublesome procedures. This has limited investigations in the area. The present article presents a new, reliable, analytical procedure, based on enzymatic degradation...... and fluorometric detection. Standards and control materials were based on milk that was stripped of intrinsic glucose and glucose 6-phosphate in order to obtain standards and samples based on the same matrix. The analysis works without pre-treatment of the samples, e.g. without centrifugation and precipitation...

  13. Impaired brain energy gain upon a glucose load in obesity.

    Science.gov (United States)

    Wardzinski, Ewelina K; Kistenmacher, Alina; Melchert, Uwe H; Jauch-Chara, Kamila; Oltmanns, Kerstin M

    2018-03-06

    There is evidence that the brain's energy status is lowered in obesity despite of chronic hypercaloric nutrition. The underlying mechanisms are unknown. We hypothesized that the brain of obese people does not appropriately generate energy in response to a hypercaloric supply. Glucose was intravenously infused in 17 normal weights and 13 obese participants until blood glucose concentrations reached the postprandial levels of 7 mmol/L and 10 mmol/L. Changes in cerebral adenosine triphosphate (ATP) and phosphocreatine (PCr) content were measured by 31 phosphorus magnetic resonance spectroscopy and stress hormonal measures regulating glucose homeostasis were monitored. Because vitamin C is crucial for a proper neuronal energy synthesis we determined circulating concentrations during the experimental testing. Cerebral high-energy phosphates were increased at blood glucose levels of 7 mmol/L in normal weights, which was completely missing in the obese. Brain energy content moderately raised only at blood glucose levels of 10 mmol/L in obese participants. Vitamin C concentrations generally correlated with the brain energy content at blood glucose concentrations of 7 mmol/L. Our data demonstrate an inefficient cerebral energy gain upon a glucose load in obese men, which may result from a dysfunctional glucose transport across the blood-brain barrier or a downregulated energy synthesis in mitochondrial oxidation processes. Our finding offers an explanation for the chronic neuroenergetic deficiency and respectively missing satiety perception in obesity. Copyright © 2018. Published by Elsevier Inc.

  14. Correlation of Salivary Glucose Level with Blood Glucose Level in Diabetes Mellitus

    OpenAIRE

    Arati S. Panchbhai

    2012-01-01

    ABSTRACT Objectives There is alarming rise in number of people with diabetes mellitus over these years. If glucose in saliva is linked to glucose in blood it can be used to detect diabetes mellitus at an early stage. The present study is undertaken with the aim to assess the correlation of salivary glucose level with blood glucose level in people with diabetes mellitus. Material and Methods For investigations, 2 sets of samples of people with diabetes and the age and sex matched non-diabetic ...

  15. Plasma kinetics of an LDL-like nanoemulsion and lipid transfer to HDL in subjects with glucose intolerance

    Directory of Open Access Journals (Sweden)

    Marina P Bertato

    2012-01-01

    Full Text Available OBJECTIVE: Glucose intolerance is frequently associated with an altered plasma lipid profile and increased cardiovascular disease risk. Nonetheless, lipid metabolism is scarcely studied in normolipidemic glucose-intolerant patients. The aim of this study was to investigate whether important lipid metabolic parameters, such as the kinetics of LDL free and esterified cholesterol and the transfer of lipids to HDL, are altered in glucose-intolerant patients with normal plasma lipids. METHODS: Fourteen glucose-intolerant patients and 15 control patients were studied; none of the patients had cardiovascular disease manifestations, and they were paired for age, sex, race and co-morbidities. A nanoemulsion resembling a LDL lipid composition (LDE labeled with 14C-cholesteryl ester and ³H-free cholesterol was intravenously injected, and blood samples were collected over a 24-h period to determine the fractional clearance rate of the labels by compartmental analysis. The transfer of free and esterified cholesterol, triglycerides and phospholipids from the LDE to HDL was measured by the incubation of the LDE with plasma and radioactivity counting of the supernatant after chemical precipitation of non-HDL fractions. RESULTS: The levels of LDL, non-HDL and HDL cholesterol, triglycerides, apo A1 and apo B were equal in both groups. The 14C-esterified cholesterol fractional clearance rate was not different between glucose-intolerant and control patients, but the ³H-free-cholesterol fractional clearance rate was greater in glucose-intolerant patients than in control patients. The lipid transfer to HDL was equal in both groups. CONCLUSION: In these glucose-intolerant patients with normal plasma lipids, a faster removal of LDE free cholesterol was the only lipid metabolic alteration detected in our study. This finding suggests that the dissociation of free cholesterol from lipoprotein particles occurs in normolipidemic glucose intolerance and may participate in

  16. Effect of glucose-insulin-potassium infusion on thallium myocardial clearance

    International Nuclear Information System (INIS)

    Wilson, R.A.; Okada, R.D.; Strauss, H.W.; Pohost, G.M.

    1983-01-01

    Factors influencing the rate of 201 Tl clearance from the myocardium have not been clearly defined. This study determined the effect of an intravenous infusion of glucose-insulin-potassium (GIK) on the net 201 Tl clearance rates from myocardium with and without initial 201 Tl loading. Anesthetized open-chest dogs underwent 5 min of left anterior descending coronary artery occlusion and intravenous 201 Tl was injected and the occlusion released 5 min later. Thirty minutes after 201 Tl injection, 30 ml of either GIK (nine dogs) or saline (five dogs) was infused intravenously. The clearance rates of 201 Tl from the anterior wall (without initial 201 Tl loading) and from the posterior wall (with initial 201 Tl loading) were monitored with miniaturized cadmium telluride detectors placed on the myocardium. Calculation of net myocardial clearance rates was performed by linear regression analysis from serial 1 min counts. Compared with saline infusion, GIK increased the net clearance of 201 Tl from both myocardial regions with and without initial loading. The most marked change induced by GIK infusion was in the myocardial region without initial 201 Tl loading; a net increase in 201 Tl activity (72 +/- 42 cpm/30 min) was converted into a net loss (-594 +/- 228 cpm/30 min). There was no significant change in 201 Tl clearance after the saline infusion. Heart rate, aortic and left atrial pressure, sonomicrometer-measured transmural myocardial wall thickness, microsphere-determined myocardial blood flow, and blood glucose and potassium concentrations did not change significantly during GIK or saline infusions. Thus, GIK infusion appears to increase net 201 Tl clearance from myocardial zones with and without initial 201 Tl loading

  17. Effect of Intravenous Infusion Solutions on Bioelectrical Impedance Spectroscopy.

    Science.gov (United States)

    Yap, Jason; Rafii, Mahroukh; Azcue, Maria; Pencharz, Paul

    2017-05-01

    Bioelectrical impedance (BIA) is often used to measure body fluid spaces and thereby body composition. However, in acute animal studies, we found that impedance was driven by the saline content of intravenous (IV) fluids and not by the volume. The aim of the study was to investigate the effect of 3 different fluids acutely administered on the change in impedance, specifically resistance (R). Nine healthy adults participated in 3 treatment (0.9% saline, 5% dextrose, and a mixture of 0.3% saline + 3.3% dextrose) experiments on nonconsecutive days. They all received 1 L of one of the treatments intravenously over a 1-hour period. Repeated BIA measurements were performed prior to IV infusion and then every 5 minutes for the 1-hour infusion period, plus 3 more measurements up to 15 minutes after the completion of the infusion. The change in R in the 0.9% saline infusion experiment was significantly lower than that of the glucose and mixture treatment ( P < .001). Bioelectrical impedance spectroscopy and BIA measure salt rather than the volume changes over the infusion period. Hence, in patients receiving IV fluids, BIA of any kind (single frequency or multifrequency) cannot be used to measure body fluid spaces or body composition.

  18. Analysis of metabolism of 6FDG: a PET glucose transport tracer

    Energy Technology Data Exchange (ETDEWEB)

    Muzic, Raymond F., E-mail: raymond.muzic@case.edu [Department of Radiology, Case Western Reserve University, Cleveland, OH 44106 (United States); Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106 (United States); Chandramouli, Visvanathan [Department of Radiology, Case Western Reserve University, Cleveland, OH 44106 (United States); Huang, Hsuan-Ming [Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106 (United States); Wu Chunying; Wang Yanming [Department of Radiology, Case Western Reserve University, Cleveland, OH 44106 (United States); Ismail-Beigi, Faramarz [Department of Medicine, Case Western Reserve University, Cleveland, OH 44106 (United States)

    2011-07-15

    Introduction: We are developing {sup 18}F-labeled 6-fluoro-6-deoxy-D-glucose ([{sup 18}F]6FDG) as a tracer of glucose transport. As part of this process it is important to characterize and quantify putative metabolites. In contrast to the ubiquitous positron emission tomography (PET) tracer {sup 18}F-labeled 2-fluoro-2-deoxy-D-glucose ([{sup 18}F]2FDG) which is phosphorylated and trapped intracellularly, the substitution of fluorine for a hydroxyl group at carbon-6 in [{sup 18}F]6FDG should prevent its phosphorylation. Consequently, [{sup 18}F]6FDG has the potential to trace the transport step of glucose metabolism without the confounding effects of phosphorylation and subsequent steps of metabolism. Herein the focus is to determine whether, and the degree to which, [{sup 18}F]6FDG remains unchanged following intravenous injection. Methods: Biodistribution studies were performed using 6FDG labeled with {sup 18}F or with the longer-lived radionuclides {sup 3}H and {sup 14}C. Tissues were harvested at 1, 6, and 24 h following intravenous administration and radioactivity was extracted from the tissues and analyzed using a combination of ion exchange columns, high-performance liquid chromatography, and chemical reactivity. Results: At the 1 h time-point, the vast majority of radioactivity in the liver, brain, heart, skeletal muscle, and blood was identified as 6FDG. At the 6-h and 24-h time points, there was evidence of a minor amount of radioactive material that appeared to be 6-fluoro-6-deoxy-D-sorbitol and possibly 6-fluoro-6-deoxy-D-gluconic acid. Conclusion: On the time scale typical of PET imaging studies radioactive metabolites of [{sup 18}F]6FDG are negligible.

  19. Continuous subcutaneous infusion of glucagon-like peptide 1 lowers plasma glucose and reduces appetite in type 2 diabetic patients

    DEFF Research Database (Denmark)

    Toft-Nielsen, M B; Madsbad, Sten; Holst, J J

    1999-01-01

    OBJECTIVE: The gut hormone glucagon-like peptide 1 (GLP-1) has insulinotropic and anorectic effects during intravenous infusion and has been proposed as a new treatment for type 2 diabetes and obesity. The effect of a single subcutaneous injection is brief because of rapid degradation. We therefo....... CONCLUSIONS: We conclude that 48-h continuous subcutaneous infusion of GLP-1 in type 2 diabetic patients 1) lowers fasting as well as meal-related plasma glucose, 2) reduces appetite, 3) has no gastrointestinal side effects, and 4) has no negative effect on blood pressure.......OBJECTIVE: The gut hormone glucagon-like peptide 1 (GLP-1) has insulinotropic and anorectic effects during intravenous infusion and has been proposed as a new treatment for type 2 diabetes and obesity. The effect of a single subcutaneous injection is brief because of rapid degradation. We therefore......, previously shown to lower blood glucose effectively in type 2 diabetic patients. Fasting plasma glucose (day 2) decreased from 14.1 +/- 0.9 (saline) to 12.2 +/- 0.7 mmol/l (GLP-1), P = 0.009, and 24-h mean plasma glucose decreased from 15.4 +/- 1.0 to 13.0 +/- 1.0 mmol/l, P = 0.0009. Fasting and total area...

  20. Gingival crevicular blood for screening of blood glucose level in patients with & without diabetes: a chair-side test.

    Science.gov (United States)

    Bhavsar, M V; Brahmbhatt, N A; Sahayata, V; Bhavsar, N V

    2016-05-01

    Diabetes is a pandemic disease with increasing prevalence and serious complications. Periodontitis being one of its presentation and is its sixth recognized complication. This study compares blood glucose levels in gingival crevicular blood of patients with and without diabetes elicited during routine periodontal probing and venous blood sample. Seventy patients with moderate gingivitis and periodontitis positive for bleeding on probing were chosen. All the subjects were divided in two groups, group I consisted of 35 diabetic and group II of 35 non-diabetic subjects. Blood from the gingiva of the most inflamed site was collected with the test strip of a glucose self-monitoring device, and the blood glucose levels were measured. At the same time, intravenous blood was collected for measurement in a laboratory glucose analyzer. Gingival index and probing pocket depth were evaluated for each subject at same time. The mean GCB levels and VB derived from all samples were 156.07 ± 49.23 mg dl(-1) and 156 ± 49.89 mg dl(-1) , respectively, for diabetic group and 90.80 ± 11.07 and 93.41 ± 9.30 for non-diabetic group. In both the groups, the difference between GCB and VB glucose levels was non-significant (P > 0.005). Highly significant correlation between GCB and VB (r = 0.972 for diabetic and r = 0.721 for non-diabetic) in both the groups was found. The data from this study show that GCB collected during diagnostic periodontal examination can be an excellent source for estimation of blood sugar or glucometric analysis. This technique is also suitable for routine screening of diabetic and early diagnosis of unknown diabetic cases. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Glucose modulates food-related salience coding of midbrain neurons in humans.

    Science.gov (United States)

    Ulrich, Martin; Endres, Felix; Kölle, Markus; Adolph, Oliver; Widenhorn-Müller, Katharina; Grön, Georg

    2016-12-01

    Although early rat studies demonstrated that administration of glucose diminishes dopaminergic midbrain activity, evidence in humans has been lacking so far. In the present functional magnetic resonance imaging study, glucose was intravenously infused in healthy human male participants while seeing images depicting low-caloric food (LC), high-caloric food (HC), and non-food (NF) during a food/NF discrimination task. Analysis of brain activation focused on the ventral tegmental area (VTA) as the origin of the mesolimbic system involved in salience coding. Under unmodulated fasting baseline conditions, VTA activation was greater during HC compared with LC food cues. Subsequent to infusion of glucose, this difference in VTA activation as a function of caloric load leveled off and even reversed. In a control group not receiving glucose, VTA activation during HC relative to LC cues remained stable throughout the course of the experiment. Similar treatment-specific patterns of brain activation were observed for the hypothalamus. The present findings show for the first time in humans that glucose infusion modulates salience coding mediated by the VTA. Hum Brain Mapp 37:4376-4384, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  2. Effects of Insulin on Brain Glucose Metabolism in Impaired Glucose Tolerance

    Science.gov (United States)

    Hirvonen, Jussi; Virtanen, Kirsi A.; Nummenmaa, Lauri; Hannukainen, Jarna C.; Honka, Miikka-Juhani; Bucci, Marco; Nesterov, Sergey V.; Parkkola, Riitta; Rinne, Juha; Iozzo, Patricia; Nuutila, Pirjo

    2011-01-01

    OBJECTIVE Insulin stimulates brain glucose metabolism, but this effect of insulin is already maximal at fasting concentrations in healthy subjects. It is not known whether insulin is able to stimulate glucose metabolism above fasting concentrations in patients with impaired glucose tolerance. RESEARCH DESIGN AND METHODS We studied the effects of insulin on brain glucose metabolism and cerebral blood flow in 13 patients with impaired glucose tolerance and nine healthy subjects using positron emission tomography (PET). All subjects underwent PET with both [18F]fluorodeoxyglucose (for brain glucose metabolism) and [15O]H2O (for cerebral blood flow) in two separate conditions (in the fasting state and during a euglycemic-hyperinsulinemic clamp). Arterial blood samples were acquired during the PET scans to allow fully quantitative modeling. RESULTS The hyperinsulinemic clamp increased brain glucose metabolism only in patients with impaired glucose tolerance (whole brain: +18%, P = 0.001) but not in healthy subjects (whole brain: +3.9%, P = 0.373). The hyperinsulinemic clamp did not alter cerebral blood flow in either group. CONCLUSIONS We found that insulin stimulates brain glucose metabolism at physiological postprandial levels in patients with impaired glucose tolerance but not in healthy subjects. These results suggest that insulin stimulation of brain glucose metabolism is maximal at fasting concentrations in healthy subjects but not in patients with impaired glucose tolerance. PMID:21270256

  3. Oral Dextrose Gel Reduces the Need for Intravenous Dextrose Therapy in Neonatal Hypoglycemia.

    Science.gov (United States)

    Rawat, Munmun; Chandrasekharan, Praveen; Turkovich, Stephen; Barclay, Nancy; Perry, Katherine; Schroeder, Eileen; Testa, Lisa; Lakshminrusimha, Satyan

    2016-01-01

    Newborn infants with risk factors may require intravenous (IV) dextrose for asymptomatic hypoglycemia. Administration of IV dextrose and transfer to the neonatal intensive care unit (NICU) may interfere with parent-infant bonding. To study the effect of implementing dextrose gel supplement with feeds in late preterm/term infants affected by asymptomatic hypoglycemia on reducing IV dextrose therapy. A retrospective study was conducted before and after dextrose gel use: 05/01/2014 to 10/31/2014 and 11/01/2014 to 04/30/2015, respectively. Asymptomatic hypoglycemic (blood glucose level dextrose gel (200 mg/kg of 40% dextrose) along with feeds. Transfer to the NICU for IV dextrose was considered treatment failure. Dextrose gel with feeds increased the blood glucose level in 184/250 (74%) of asymptomatic hypoglycemic infants compared to 144/248 (58%) with feeds only (p dextrose decreased from 35/1,000 to 25/1,000 live births (p dextrose gel with feeds reduced the need for IV fluids, avoided separation from the mother and promoted breastfeeding. Neonates who failed dextrose gel therapy were more likely to be large for gestational age, delivered by cesarean section and had lower baseline blood glucose levels.

  4. 18F-fluorodeoxyglucose accumulation in the heart, brain and skeletal muscle of rats; the influence of time after injection, depressed lipid metabolism and glucose-insulin

    International Nuclear Information System (INIS)

    Kasalicky, J.; Konopkova, M.; Melichar, F.

    2001-01-01

    To study the effect of lipid depressing drugs on 18 FDG myocardial concentration. The changes of 18 FDG uptake in myocardium, brain and skeletal muscle of rats were compared as influenced by acipimox, tyloxapol and glucose with insulin. 5.55 MBq of 18 FDG were administered to Wistar rats. Control rats were killed 15, 30, 45 and 60 minutes following intravenous injection and the radioactivity concentration (cpm/g of tissue) in relation to injected cpm was determined in a well crystal adjusted to 511 KeV in order to check the time of maximal 18 FDG tissue uptake. The radioactivity in myocardium, skeletal muscle and brain in intact animals was compared with that of rats treated with tyloxapol (tritton WR 1339, 125 mg intravenously immediately before 18 FDG injection), acipimox (nicotinic acid derivative, 25 mg by stomach cannula 15 minutes before 18 FDG), or glucose with insulin (intravenous injection of 0.04 g and 0.04 UI immediately before 18 FDG). The animals were killed 45 minutes following 18 FDG injection. Tyloxapol and acipimox significantly elevated myocardial 18 FDG concentration (tyloxapol +37% and acipimox +48%), but the increase in 18 FDG concentration after glucose and insulin was slight and insignificant. The changes in skeletal muscle after lipid depressing agents were quite contrasting; the decrease in 18 FDG concentration was -74% after tyloxapol and -44% following acipimox administration. The accumulation of 18 FDG in brain was not influenced markedly by the drugs used or by glucose with insulin. The highest 18 FDG uptake in myocardium could be achieved by depressing the lipid metabolism and not by administration of glucose with insulin only. A marked increase in glucose accumulation in myocardium is not possible without previous shift from the utilisation of fatty acids. This finding is fully in agreement with present knowledge about energetic metabolism of myocardium. (author)

  5. [Intravenous rehydration for diarrheal dehydration of eutrophic children: survey of protocols provided at Colombian medical schools].

    Science.gov (United States)

    Flórez, Iván Darío; Ramos, Esteban; Bernal, Carlos; Cuéllar, Olga Juliana; Cornejo, José William

    2011-01-01

    In all cases of severe dehydration from diarrhea, WHO recommends rapid rehydration. If oral rehydration in children is contraindicated, intravenous rehydration is recommended for immediate administration. However, methods of intravenous rehydration appear to be inadequately addressed in the medical schools of Colombia. Current approaches to oral rehydration were summarized, and instructors were informed concerning current WHO recommendations. A survey was designed for pediatric instructors in Colombian medical schools. Direct questions about rehydration methods were included as well as presentation of theoretical clinical situations with dehydrated children. The survey also asked for the conditions necessary for intravenous rehydration and method of administration (volume, solution, concentration and speed of infusion). Forty-one surveys were included (82% of medical schools in Colombia). Inadequate contraindications for oral rehydration therapy were made in 41%. Rapid and slow intravenous rehydration was recommended in 71% and 29%, respectively; 57% recommended fluid bolus to rehydrate. Adequate volumes were recommended by less than half of the respondents and adequate sodium concentration was recommended by 85%. In 56% of medical schools, glucose was not included in solutions and 66% use Ringer lactate. Normal saline solution, dextrose solution with electrolytes and polyelectrolytes solutions are also used. Misconceptions are common concerning the contraindications to oral rehydration therapy. One-third of medical schools promote a slow therapy despite the superiority of the rapid therapy. Uniformity for rapid therapy schemes is lacking. Bolus rehydration is commonly advocated despite the fact that this method is unsupported by the literature. Concepts about rehydration must be updated in medical schools and a national guide for intravenous rehydration is recommended.

  6. Evaluation of Postprandial Glucose Excursion Using a Novel Minimally Invasive Glucose Area-Under-the-Curve Monitoring System

    OpenAIRE

    Kuranuki, Sachi; Sato, Toshiyuki; Okada, Seiki; Hosoya, Samiko; Seko, Akinobu; Sugihara, Kaya; Nakamura, Teiji

    2013-01-01

    Objective: To develop a minimally invasive interstitial fluid extraction technology (MIET) to monitor postprandial glucose area under the curve (AUC) without blood sampling, we evaluated the accuracy of glucose AUC measured by MIET and compared with that by blood sampling after food intake. Methods: Interstitial fluid glucose AUC (IG-AUC) following consumption of 6 different types of foods was measured by MIET. MIET consisted of stamping microneedle arrays, placing hydrogel patches on the are...

  7. Reduced cerebral glucose metabolism and increased brain capillary permeability following high-dose methotrexate chemotherapy: a positron emission tomographic study

    International Nuclear Information System (INIS)

    Phillips, P.C.; Dhawan, V.; Strother, S.C.; Sidtis, J.J.; Evans, A.C.; Allen, J.C.; Rottenberg, D.A.

    1987-01-01

    Regional glucose metabolic rate constants and blood-to-brain transport of rubidium were estimated using positron emission tomography in an adolescent patient with a brain tumor, before and after chemotherapy with intravenous high-dose methotrexate. Widespread depression of cerebral glucose metabolism was apparent 24 hours after drug administration, which may reflect reduced glucose phosphorylation, and the influx rate constant for 82 Rb was increased, indicating a drug-induced alteration in blood-brain barrier function. Associated changes in neuropsychological performance, electroencephalogram, and plasma amino acid concentration were identified in the absence of evidence of systemic methotrexate toxicity, suggesting primary methotrexate neurotoxicity

  8. Glucagon-like peptide-2, but not glucose-dependent insulinotropic polypeptide, stimulates glucagon release in patients with type 1 diabetes

    DEFF Research Database (Denmark)

    Christensen, Mikkel; Knop, Filip K; Vilsbøll, Tina

    2010-01-01

    This study investigated the glucagon-releasing properties of the hormones glucagon-like peptide-2 (GLP-2) and glucose-dependent insulinotropic polypeptide (GIP) in 8 patients with type 1 diabetes mellitus (T1DM) without paracrine intraislet influence of insulin (C-peptide negative following a 5 g...... intravenous arginine stimulation; on study days only treated with basal insulin substitution). On 3 study days, 180-minute two-step glucose clamps were performed. Plasma glucose (PG) was clamped at fasting values, with a mean of 7.4+/-0.5 mM in the first 90 min (period 1) and raised 1.5 times the fasting...

  9. Glucose utilisation in the lungs of septic rats

    International Nuclear Information System (INIS)

    Hansson, L.; Jeppsson, B.; Ohlsson, T.; Sandell, A.; Valind, S.; Luts, A.; Wollmer, P.

    1999-01-01

    Sequestration and degranulation of leucocytes in the pulmonary microcirculation is considered to be a key event in the development of acute respiratory distress syndrome in patients with sepsis. Glucose serves as the main source of energy in activated leucocytes. The aim of this study was to assess whether glucose utilisation in the lungs can be used as an indicator of pulmonary leucocyte accumulation in an experimental model of sepsis of intra-abdominal origin. Sepsis was induced in rats by abdominal implantation of a gelatine capsule containing bacteria and rat colonic contents. Empty gelatine capsules were implanted in control animals. Animals were studied 6 and 12 h after sepsis induction. Glucose utilisation was measured as the tissue uptake of fluorine-18-fluorodeoxyglucose ( 18 FDG) 1 h after intravenous injection of the tracer. Micro-autoradiography was also performed after injection of tritiated deoxyglucose. We found increased uptake of 18 FDG in the lungs of septic animals. The uptake also increased with time after sepsis induction. 18 FDG uptake in circulating leucocytes was increased in septic animals compared with controls, and micro-autoradiography showed intense accumulation of deoxyglucose in leucocytes in the lungs of septic animals. We conclude that glucose utilisation is increased in the lungs of septic rats. Measurements of pulmonary glucose utilisation as an index of leucocyte metabolic activity may open new possibilities for studies of the pathophysiology of sepsis and for evaluation of therapeutic interventions. (orig.)

  10. 13C NMR for the assessment of human brain glucose metabolism in vivo

    International Nuclear Information System (INIS)

    Beckman, N.; Seelig, J.; Turkalj, I.; Keller, U.

    1991-01-01

    Proton-decoupled 13 C NMR spectra of the human head were obtained during hyperglycemic glucose clamping using intravenous infusions of [1- 13 C]glucose in normal volunteers. In addition to 13 C signals of mobile lipids, a variety of new metabolite resonances could be resolved for the first time in the human brain. At an enrichment level of 20% [1- 13 C]glucose, the signals of α- and β-glucose at 92.7 and 96.6 ppm, respectively, could be detected in the human brain after only an infusion period of 15 minutes. The spatial localization of the different regions of interest was confirmed by 13 C NMR spectroscopic imaging with a time resolution of 9 minutes. Increasing the enrichment level to 99% [1- 13 C]glucose not only improved the time resolution but allowed the detection of metabolic breakdown products of [1- 13 C]glucose. The time course of 13 C label incorporation into the C 2 , C 3 , and C 4 resonances of glutamate/glutamine and into lactate could be recorded in the human brain. These results suggest the possibility of obtaining time-resolved, spatially selective, and chemically specific information on the human body

  11. Glucose metabolism disorder in obese children assessed by continuous glucose monitoring system.

    Science.gov (United States)

    Zou, Chao-Chun; Liang, Li; Hong, Fang; Zhao, Zheng-Yan

    2008-02-01

    Continuous glucose monitoring system (CGMS) can measure glucose levels at 5-minute intervals over a few days, and may be used to detect hypoglycemia, guide insulin therapy, and control glucose levels. This study was undertaken to assess the glucose metabolism disorder by CGMS in obese children. Eighty-four obese children were studied. Interstitial fluid (ISF) glucose levels were measured by CGMS for 24 hours covering the time for oral glucose tolerance test (OGTT). Impaired glucose tolerance (IGT), impaired fasting glucose (IFG), type 2 diabetic mellitus (T2DM) and hypoglycemia were assessed by CGMS. Five children failed to complete CGMS test. The glucose levels in ISF measured by CGMS were highly correlated with those in capillary samples (r=0.775, Pobese children who finished the CGMS, 2 children had IFG, 2 had IGT, 3 had IFG + IGT, and 2 had T2DM. Nocturnal hypoglycemia was noted during the overnight fasting in 11 children (13.92%). Our data suggest that glucose metabolism disorder including hyperglycemia and hypoglycemia is very common in obese children. Further studies are required to improve the precision of the CGMS in children.

  12. First-pass metabolism of ethanol in human beings: effect of intravenous infusion of fructose

    DEFF Research Database (Denmark)

    Parlesak, Alexandr; Billinger, MH; Schäfer, C.

    2004-01-01

    Intravenous infusion of fructose has been shown to enhance reduced form of nicotinamide adenine dinucleotide reoxidation and, thereby, to enhance the metabolism of ethanol. In the current study, the effect of fructose infusion on first-pass metabolism of ethanol was studied in human volunteers....... A significantly higher first-pass metabolism of ethanol was obtained after administration of fructose in comparison with findings for control experiments with an equimolar dose of glucose. Because fructose is metabolized predominantly in the liver and can be presumed to have virtually no effects in the stomach...

  13. Lactate overrides central nervous but not beta-cell glucose sensing in humans.

    Science.gov (United States)

    Schmid, Sebastian M; Jauch-Chara, Kamila; Hallschmid, Manfred; Oltmanns, Kerstin M; Peters, Achim; Born, Jan; Schultes, Bernd

    2008-12-01

    Lactate has been shown to serve as an alternative energy substrate in the central nervous system and to interact with hypothalamic glucose sensors. On the background of marked similarities between central nervous and beta-cell glucose sensing, we examined whether lactate also interacts with pancreatic glucose-sensing mechanisms in vivo. The effects of intravenously infused lactate vs placebo (saline) on central nervous and pancreatic glucose sensing were assessed during euglycemic and hypoglycemic clamp experiments in 10 healthy men. The release of neuroendocrine counterregulatory hormones during hypoglycemia was considered to reflect central nervous glucose sensing, whereas endogenous insulin secretion as assessed by serum C-peptide levels served as an indicator of pancreatic beta-cell glucose sensing. Lactate infusion blunted the counterregulatory hormonal responses to hypoglycemia, in particular, the release of epinephrine (P = .007) and growth hormone (P = .004), so that higher glucose infusion rates (P = .012) were required to maintain the target blood glucose levels. In contrast, the decrease in C-peptide concentrations during the hypoglycemic clamp remained completely unaffected by lactate (P = .60). During euglycemic clamp conditions, lactate infusion did not affect the concentrations of C-peptide and of counterregulatory hormones, with the exception of norepinephrine levels that were lower during lactate than saline infusion (P = .049) independently of the glycemic condition. Data indicate that glucose sensing of beta-cells is specific to glucose, whereas glucose sensing at the central nervous level can be overridden by lactate, reflecting the brain's ability to rely on lactate as an alternative major energy source.

  14. Electron-transfer mediator for a NAD-glucose dehydrogenase-based glucose sensor.

    Science.gov (United States)

    Kim, Dong-Min; Kim, Min-yeong; Reddy, Sanapalli S; Cho, Jaegeol; Cho, Chul-ho; Jung, Suntae; Shim, Yoon-Bo

    2013-12-03

    A new electron-transfer mediator, 5-[2,5-di (thiophen-2-yl)-1H-pyrrol-1-yl]-1,10-phenanthroline iron(III) chloride (FePhenTPy) oriented to the nicotinamide adenine dinucleotide-dependent-glucose dehydrogenase (NAD-GDH) system was synthesized through a Paal-Knorr condensation reaction. The structure of the mediator was confirmed by Fourier-transform infrared spectroscopy, proton and carbon nucler magnetic resonance spectroscopy, and mass spectroscopy, and its electron-transfer characteristic for a glucose sensor was investigated using voltammetry and impedance spectroscopy. A disposable amperometric glucose sensor with NAD-GDH was constructed with FePhenTPy as an electron-transfer mediator on a screen printed carbon electrode (SPCE) and its performance was evaluated, where the addition of reduces graphene oxide (RGO) to the mediator showed the enhanced sensor performance. The experimental parameters to affect the analytical performance and the stability of the proposed glucose sensor were optimized, and the sensor exhibited a dynamic range between 30 mg/dL and 600 mg/dL with the detection limit of 12.02 ± 0.6 mg/dL. In the real sample experiments, the interference effects by acetaminophen, ascorbic acid, dopamine, uric acid, caffeine, and other monosaccharides (fructose, lactose, mannose, and xylose) were completely avoided through coating the sensor surface with the Nafion film containing lead(IV) acetate. The reliability of proposed glucose sensor was evaluated by the determination of glucose in artificial blood and human whole blood samples.

  15. Amino Acid Metabolism in Acute Renal Failure: Influence of Intravenous Essential L-Amino Acid Hyperalimentation Therapy

    Science.gov (United States)

    Abel, Ronald M.; Shih, Vivian E.; Abbott, William M.; Beck, Clyde H.; Fischer, Josef E.

    1974-01-01

    A solution of 8 essential I-amino acids and hypertonic dextrose was administered to 5 patients in acute postoperative renal failure in a program of hyperalimentation designed to decrease the patient's catabolic state and to accrue certain metabolic benefits. A sixth patient receiving intravenous glucose alone served as a control. The pretreatment plasma concentrations of amino acids in all 6 patients did not differ significantly from normal; following intravenous essential amino acids at a dose of approximately 12.6 gm/24 hours, no significant elevations out of the normal range of these substances occurred. Since urinary excretion rates did not dramatically increase, urinary loss was excluded as a possible cause for the failure of increase of plasma concentrations. The results suggest that the administration of an intravenous solution of 1-amino acids and hypertonic dextrose is associated with rapid clearance from the blood of these substances and, with a failure of increased urinary excretion, indirect evidence of amino acid utilization for protein synthesis has been obtained. Histidine supplementation in patients with acute renal failure is probably unnecessary based on the lack of significant decreases in histidine concentrations in these patients. PMID:4850497

  16. Intentional intravenous mercury injection

    African Journals Online (AJOL)

    In this case report, intravenous complications, treatment strategies and possible ... Mercury toxicity is commonly associated with vapour inhalation or oral ingestion, for which there exist definite treatment options. Intravenous mercury ... personality, anxiousness, irritability, insomnia, depression and drowsi- ness.[1] However ...

  17. Normalization of glucose concentrations and deceleration of gastric emptying after solid meals during intravenous glucagon-like peptide 1 in patients with type 2 diabetes

    DEFF Research Database (Denmark)

    Meier, Juris J; Gallwitz, Baptist; Salmen, Stefan

    2003-01-01

    in the fasting state and after a solid test meal (containing [(13)C]octanoic acid). Blood was drawn for glucose, insulin, C-peptide, glucagon, and GLP-1 determinations. The gastric emptying rate was calculated from the (13)CO(2) excretion rates in breath samples. Statistics were determined using repeated......The effects of different i.v. doses of glucagon-like peptide 1 (GLP-1) on glucose homeostasis and gastric emptying were compared in patients with type 2 diabetes. Twelve patients with type 2 diabetes received three different infusion rates of GLP-1 (0.4, 0.8, and 1.2 pmol/kg x min) or placebo...... ingestion (P = 0.0031 and 0.0074, respectively). Glucagon secretion was suppressed with GLP-1. Gastric emptying was decelerated by GLP-1 in a dose-dependent fashion (P

  18. Dry period plane of energy: Effects on glucose tolerance in transition dairy cows.

    Science.gov (United States)

    Mann, S; Leal Yepes, F A; Duplessis, M; Wakshlag, J J; Overton, T R; Cummings, B P; Nydam, D V

    2016-01-01

    Overfeeding energy in the dry period can affect glucose metabolism and the energy balance of transition dairy cows with potential detrimental effects on the ability to successfully adapt to early lactation. The objectives of this study were to investigate the effect of different dry cow feeding strategies on glucose tolerance and on resting concentrations of blood glucose, glucagon, insulin, nonesterified fatty acids (NEFA), and β-hydroxybutyrate (BHB) in the peripartum period. Cows entering second or greater lactation were enrolled at dry-off (57 d before expected parturition) into 1 of 3 treatment groups following a randomized block design: cows that received a total mixed ration (TMR) formulated to meet but not exceed energy requirements during the dry period (n=28, controlled energy); cows that received a TMR supplying approximately 150% of energy requirements during the dry period (n=28, high energy); and cows that were fed the same diet as the controlled energy group for the first 28 d, after which the TMR was formulated to supply approximately 125% of energy requirements until calving (n=28, intermediate energy). Intravenous glucose tolerance tests (IVGTT) with rapid administration of 0.25 g of glucose/kg of body weight were performed 28 and 10d before expected parturition, as well as at 4 and 21 d after calving. Area under the curve for insulin and glucose, maximal concentration and time to half-maximal concentration of insulin and glucose, and clearance rates were calculated. Insulin resistance (IR) indices were calculated from baseline samples obtained during IVGTT and Spearman rank correlations determined between IVGTT parameters and IR indices. Treatment did not affect IVGTT parameters at any of the 4 time points. Correlation between IR indices and IVGTT parameters was generally poor. Overfeeding cows energy in excess of predicted requirements by approximately 50% during the entire dry period resulted in decreased postpartum basal plasma glucose and

  19. Insulin-coated gold nanoparticles as a new concept for personalized and adjustable glucose regulation

    Science.gov (United States)

    Shilo, Malka; Berenstein, Peter; Dreifuss, Tamar; Nash, Yuval; Goldsmith, Guy; Kazimirsky, Gila; Motiei, Menachem; Frenkel, Dan; Brodie, Chaya; Popovtzer, Rachela

    2015-12-01

    Diabetes mellitus is a chronic metabolic disease, characterized by high blood glucose levels, affecting millions of people around the world. Currently, the main treatment for diabetes requires multiple daily injections of insulin and self-monitoring of blood glucose levels, which markedly affect patients' quality of life. In this study we present a novel strategy for controlled and prolonged glucose regulation, based on the administration of insulin-coated gold nanoparticles (INS-GNPs). We show that both intravenous and subcutaneous injection of INS-GNPs into a mouse model of type 1 diabetes decreases blood glucose levels for periods over 3 times longer than free insulin. We further showed that conjugation of insulin to GNPs prevented its rapid degradation by the insulin-degrading-enzyme, and thus allows controlled and adjustable bio-activity. Moreover, we assessed different sizes and concentrations of INS-GNPs, and found that both parameters have a critical effect in vivo, enabling specific adjustment of blood glucose levels. These findings have the potential to improve patient compliance in diabetes mellitus.

  20. Evaluation of Glucose-6-Phosphate Dehydrogenase stability in stored blood samples.

    Science.gov (United States)

    Jalil, Norunaluwar; Azma, Raja Zahratul; Mohamed, Emida; Ithnin, Azlin; Alauddin, Hafiza; Baya, Siti Noor; Othman, Ainoon

    2016-01-01

    Glucose-6-Phosphate Dehydrogenase (G6PD) deficiency is the commonest cause of neonatal jaundice in Malaysia. Recently, OSMMR2000-D G6PD Assay Kit has been introduced to quantitate the level of G6PD activity in newborns delivered in Universiti Kebangsaan Malaysia Medical Centre (UKMMC). As duration of sample storage prior to analysis is one of the matters of concern, this study was conducted to identify the stability of G6PD enzyme during storage. A total of 188 cord blood samples from normal term newborns delivered at UKMMC were selected for this study. The cord bloods samples were collected in ethylene-diamine-tetra-acetic acid (EDTA) tubes and refrigerated at 2-8 °C. In addition, 32 out of 188 cord blood samples were spotted on chromatography paper, air-dried and stored at room temperature. G6PD enzyme activities were measured daily for 7 days using the OSMMR2000-D G6PD Assay Kit on both the EDTA blood and dried blood samples. The mean value for G6PD activity was compared between days of analysis using Student Paired T-Test. In this study, 172 out of 188 cord blood samples showed normal enzyme levels while 16 had levels corresponding to severe enzyme deficiency. The daily mean G6PD activity for EDTA blood samples of newborns with normal G6PD activity showed a significant drop on the fourth day of storage (p samples with severely deficient G6PD activity, significant drop was seen on third day of storage (p = 0.002). Analysis of dried cord blood showed a significant reduction in enzyme activity as early as the second day of storage (p = 0.001). It was also noted that mean G6PD activity for spotted blood samples were lower compared to those in EDTA tubes for all days (p = 0.001). Thus, EDTA blood samples stored at 2-8 °C appeared to have better stability in terms of their G6PD enzyme level as compared to dried blood samples on filter paper, giving a storage time of up to 3 days.

  1. The estrogen hypothesis of schizophrenia implicates glucose metabolism: association study in three independent samples

    DEFF Research Database (Denmark)

    Olsen, Line; Hansen, Thomas; Jakobsen, Klaus D.

    2008-01-01

    networks implicated by the candidate genes resulting from the estrogen selection. We identified ten candidate genes using this approach that are all active in glucose metabolism and particularly in the glycolysis. Thus, we tested the hypothesis that variants of the glycolytic genes are associated...... to nationality or gender. CONCLUSION: Several gene variants in the Glycolysis were associated with schizophrenia in three independent samples. However, the findings are weak and not resistant to correction for multiple testing, which may indicate that they are either spurious or may relate to a particular...

  2. Defective glucose and lipid metabolism in human immunodeficiency virus-infected patients with lipodystrophy involve liver, muscle tissue and pancreatic beta-cells

    DEFF Research Database (Denmark)

    Haugaard, Steen B; Andersen, Ove; Dela, Flemming

    2005-01-01

    ), 18 patients without lipodystrophy on HAART (NONLIPO) and seven patients who were naive to antiretroviral therapy (NAIVE) respectively). beta-cell function was evaluated by an intravenous glucose tolerance test. RESULTS: Compared with NONLIPO and NAIVE separately, LIPO displayed markedly reduced ratio...... of limb to trunk fat (RLF; > 34%, P 40%, P disposal (>50%, P 50%, P ... acids (P disposal (r = 0.71) and incremental exogenous glucose storage (r = 0.40), all P

  3. Effect of in vivo injection of cholera and pertussis toxin on glucose transport in rat skeletal muscle

    DEFF Research Database (Denmark)

    Ploug, Thorkil; Han, X; Petersen, L N

    1997-01-01

    Cholera toxin (CTX) and pertussis toxin (PTX) were examined for their ability to inhibit glucose transport in perfused skeletal muscle. Twenty-five hours after an intravenous injection of CTX, basal transport was decreased approximately 30%, and insulin- and contraction-stimulated transport...... in GLUT-1 protein content was found. In contrast, GLUT-4 mRNA was unchanged, but transcripts for GLUT-1 were increased > or = 150% in all three muscles from CTX-treated rats. The findings suggest that CTX via increased cAMP impairs basal as well as insulin- and contraction-stimulated muscle glucose...

  4. Correlation of salivary glucose level with blood glucose level in diabetes mellitus.

    Science.gov (United States)

    Gupta, Shreya; Nayak, Meghanand T; Sunitha, J D; Dawar, Geetanshu; Sinha, Nidhi; Rallan, Neelakshi Singh

    2017-01-01

    Saliva is a unique fluid, which is important for normal functioning of the oral cavity. Diabetes mellitus (DM) is a disease of absolute or relative insulin deficiency characterized by insufficient secretion of insulin by pancreatic beta-cells. The diagnosis of diabetes through blood is difficult in children, older adults, debilitated and chronically ill patients, so diagnosis by analysis of saliva can be potentially valuable as collection of saliva is noninvasive, easier and technically insensitive, unlike blood. The aim of the study was to correlate blood glucose level (BGL) and salivary glucose level (SGL) in DM patients. A cross-sectional study was conducted in 120 patients, who were categorized as 40 controlled diabetics, 40 uncontrolled diabetics and 40 healthy, age- and sex-matched individuals constituted the controls. The blood and unstimulated saliva samples were collected from the patients at the different intervals for fasting, random and postprandial levels. These samples were then subjected for analysis of glucose in blood and saliva using glucose oxidase/peroxidase reagent in HITACHI 902 (R) Automatic analyzer, and the results were recorded. The mean SGLs were higher in uncontrolled and controlled diabetic groups than in nondiabetic group. A highly statistically significant correlation was found between fasting saliva glucose and fasting blood glucose in all the groups. With increase in BGL, increase in SGL was observed in patients with diabetes suggesting that SGL can be used for monitoring glycemic level in DM.

  5. Novel fungal FAD glucose dehydrogenase derived from Aspergillus niger for glucose enzyme sensor strips.

    Science.gov (United States)

    Sode, Koji; Loew, Noya; Ohnishi, Yosuke; Tsuruta, Hayato; Mori, Kazushige; Kojima, Katsuhiro; Tsugawa, Wakako; LaBelle, Jeffrey T; Klonoff, David C

    2017-01-15

    In this study, a novel fungus FAD dependent glucose dehydrogenase, derived from Aspergillus niger (AnGDH), was characterized. This enzyme's potential for the use as the enzyme for blood glucose monitor enzyme sensor strips was evaluated, especially by investigating the effect of the presence of xylose during glucose measurements. The substrate specificity of AnGDH towards glucose was investigated, and only xylose was found as a competing substrate. The specific catalytic efficiency for xylose compared to glucose was 1.8%. The specific activity of AnGDH for xylose at 5mM concentration compared to glucose was 3.5%. No other sugars were used as substrate by this enzyme. The superior substrate specificity of AnGDH was also demonstrated in the performance of enzyme sensor strips. The impact of spiking xylose in a sample with physiological glucose concentrations on the sensor signals was investigated, and it was found that enzyme sensor strips using AnGDH were not affected at all by 5mM (75mg/dL) xylose. This is the first report of an enzyme sensor strip using a fungus derived FADGDH, which did not show any positive bias at a therapeutic level xylose concentration on the signal for a glucose sample. This clearly indicates the superiority of AnGDH over other conventionally used fungi derived FADGDHs in the application for SMBG sensor strips. The negligible activity of AnGDH towards xylose was also explained on the basis of a 3D structural model, which was compared to the 3D structures of A. flavus derived FADGDH and of two glucose oxidases. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Increases in Intravenous Magnesium Use among Hospitalized Patients: An Institution Cross-Sectional Experience

    Directory of Open Access Journals (Sweden)

    Bryce A. Kiberd

    2015-06-01

    Full Text Available Background: Among hospitalized patients, indications for the measurement of magnesium levels and treatment of hypomagnesemia with intravenous magnesium are not well defined. Recently, there have been reports of worldwide shortages of intravenous magnesium sulphate. Objective: To examine secular trends in the administration of intravenous magnesium on hospital wards at a tertiary care institution. The secondary objective is to identify factors associated with magnesium use among admitted patients. Methods: Retrospective cross-section review of hospitalized patients at a single Canadian tertiary care center. Utilization of non-parental nutrition intravenous magnesium from 2003 to 2013 stratified by hospital ward was examined. In addition, patient level data from select wards (including medical and surgical services was examined at early and more recent time period (4/2006 versus 4/2013. Results: Among the 248,329 hospitalized patients, intravenous magnesium use increased by 2.86 fold from 2003 to 2013. Not all wards had an increase whereas some had nearly a 10 fold increase in use. In the sample ( n = 769, (adjusting for admission magnesium level, presence of an indication for intravenous magnesium, ward location, comorbidity and demographics intravenous magnesium administration was higher (25.8 % versus 5.5 % in 2013 versus 2006 (OR 13.91 (95 % CI, 6.21–31.17, p < 0.001. Despite this increase in intravenous magnesium administration, <3 % of patients were admitted on oral magnesium in 2006 and 2013. For patients receiving intravenous magnesium only a minority were discharged on oral therapy despite low levels. Conclusions: This center has witnessed a considerable increase in the use of in-hospital intravenous magnesium over the last 6 years that cannot be explained for by medical indications. The risks and benefits of this therapy deserve further study. If this change in practice is representative of other North American hospitals, it may be

  7. Exenatide augments first- and second-phase insulin secretion in response to intravenous glucose in subjects with type 2 diabetes

    DEFF Research Database (Denmark)

    Fehse, Frauke; Trautmann, Michael; Holst, Jens Juul

    2005-01-01

    CONTEXT: First-phase insulin secretion (within 10 min after a sudden rise in plasma glucose) is reduced in type 2 diabetes mellitus (DM2). The incretin mimetic exenatide has glucoregulatory activities in DM2, including glucose-dependent enhancement of insulin secretion. OBJECTIVE: The objective...... of the study was to determine whether exenatide can restore a more normal pattern of insulin secretion in subjects with DM2. DESIGN: Fasted subjects received iv insulin infusion to reach plasma glucose 4.4-5.6 mmol/liter. Subjects received iv exenatide (DM2) or saline (DM2 and healthy volunteers), followed...... by iv glucose challenge. PATIENTS: Thirteen evaluable DM2 subjects were included in the study: 11 males, two females; age, 56 +/- 7 yr; body mass index, 31.7 +/- 2.4 kg/m2; hemoglobin A1c, 6.6 +/- 0.7% (mean +/- sd) treated with diet/exercise (n = 1), metformin (n = 10), or acarbose (n = 2). Controls...

  8. Evaluation of the effects of insufficient blood volume samples on the performance of blood glucose self-test meters.

    Science.gov (United States)

    Pfützner, Andreas; Schipper, Christina; Ramljak, Sanja; Flacke, Frank; Sieber, Jochen; Forst, Thomas; Musholt, Petra B

    2013-11-01

    Accuracy of blood glucose readings is (among other things) dependent on the test strip being completely filled with sufficient sample volume. The devices are supposed to display an error message in case of incomplete filling. This laboratory study was performed to test the performance of 31 commercially available devices in case of incomplete strip filling. Samples with two different glucose levels (60-90 and 300-350 mg/dl) were used to generate three different sample volumes: 0.20 µl (too low volume for any device), 0.32 µl (borderline volume), and 1.20 µl (low but supposedly sufficient volume for all devices). After a point-of-care capillary reference measurement (StatStrip, NovaBiomedical), the meter strip was filled (6x) with the respective volume, and the response of the meters (two devices) was documented (72 determinations/meter type). Correct response was defined as either an error message indicating incomplete filling or a correct reading (±20% compared with reference reading). Only five meters showed 100% correct responses [BGStar and iBGStar (both Sanofi), ACCU-CHEK Compact+ and ACCU-CHEK Mobile (both Roche Diagnostics), OneTouch Verio (LifeScan)]. The majority of the meters (17) had up to 10% incorrect reactions [predominantly incorrect readings with sufficient volume; Precision Xceed and Xtra, FreeStyle Lite, and Freedom Lite (all Abbott); GlucoCard+ and GlucoMen GM (both Menarini); Contour, Contour USB, and Breeze2 (all Bayer); OneTouch Ultra Easy, Ultra 2, and Ultra Smart (all LifeScan); Wellion Dialog and Premium (both MedTrust); FineTouch (Terumo); ACCU-CHEK Aviva (Roche); and GlucoTalk (Axis-Shield)]. Ten percent to 20% incorrect reactions were seen with OneTouch Vita (LifeScan), ACCU-CHEK Aviva Nano (Roche), OmniTest+ (BBraun), and AlphaChek+ (Berger Med). More than 20% incorrect reactions were obtained with Pura (Ypsomed), GlucoCard Meter and GlucoMen LX (both Menarini), Elite (Bayer), and MediTouch (Medisana). In summary, partial and

  9. Pharmacokinetics of high-dose intravenous melatonin in humans

    DEFF Research Database (Denmark)

    Andersen, Lars P H; Werner, Mads U; Rosenkilde, Mette Marie

    2016-01-01

    This crossover study investigated the pharmacokinetics and adverse effects of high-dose intravenous melatonin. Volunteers participated in 3 identical study sessions, receiving an intravenous bolus of 10 mg melatonin, 100 mg melatonin, and placebo. Blood samples were collected at baseline and 0, 60......, 120, 180, 240, 300, 360, and 420 minutes after the bolus. Quantitative determination of plasma melatonin concentrations was performed using a radioimmunoassay technique. Pharmacokinetic parameters were estimated by a compartmental pharmacokinetic analysis. Adverse effects included assessments...... of sedation and registration of other symptoms. Sedation, evaluated as simple reaction times, was measured at baseline and 120, 180, 300, and 420 minutes after the bolus. Twelve male volunteers completed the study. Median (IQR) Cmax after the bolus injections of 10 mg and 100 mg of melatonin were 221...

  10. Effects of vanadium supplementation on performance, some plasma metabolites and glucose metabolism in Mahabadi goat kids.

    Science.gov (United States)

    Zarqami, A; Ganjkhanlou, M; Zali, A; Rezayazdi, K; Jolazadeh, A R

    2018-04-01

    This experiment was conducted to investigate the effects of vanadium (V) supplementation on performance, some plasma metabolites (cholesterol and triglycerides) and glucose metabolism in Mahabadi goat kids. Twenty-eight male kids (15 ± 2 kg body weight) were fed for 14 weeks in a completely randomized design with four treatments. Treatments were supplemented with 0 (control), 1, 2, and 3 mg V as vanadyl sulfate/animal/daily. On day 70, an intravenous glucose tolerance test (IVGTT) was conducted. Dry matter intake did not change by V supplementation, but adding V quadraticaly improved feed efficiency (p = .03) and tended to increase average daily gain (Quadratic, p = .09). Blood metabolites were unaffected by V supplementation, except for concentration of glucose in plasma, which decreased linearly as supplemental V level increased (p = .02). Plasma glucose concentrations at 15, 30, 45 and 60 min after glucose infusion were decreased in a quadratic fashion in response to increasing supplemental V level (p kids supplemented with 2 mg V had higher glucose clearance rate (K) and lower glucose half-life (T ½ ; p kids. © 2017 Blackwell Verlag GmbH.

  11. Ultrastructural Changes in the Liver of Intravenous Heroin Addicts

    Directory of Open Access Journals (Sweden)

    Goran Ilić

    2010-02-01

    Full Text Available The ultrastructural research has a decisive role in gathering the knowledge on the liver’s response to the influence of some drugs. The aim of the study was to perform an ultrastructurai analysis of the liver in chronic intravenous heroin addicts.The study involved the autopsy conducted on 40 bodies of intravenous heroin addicts and 10 control autopsies. The liver tissue was fixed in glutaraldehyde and moulded with epon for investigation purposes of ultrastructural changes. The analysis was performed using the method of transmission electron microscopy.In the group of intravenous heroin addicts, the liver autopsy samples showed degenerative vesicular and fat changes, chronic active and persistent hepatitis, cirrhosis, reduction in the amount of glycogen in hepatocytes, as well as the Kupffer cell’s dominant hypertrophy. Various changes occur in organelles, plasma membrane of hepatocytes and biliary channels as well as in the nucleus.The most important ultrastructural findings include: hyperplasia and hypertrophy of the smooth endoplasmic reticulum, which is histologically proven vesicular degeneration of hepatocyte occurring as a result of the increased synthesis of enzymes of smooth endoplasmic reticulum due to chronic intravenous heroin intake, and the presence of continuous basal membrane followed by transformation of the sinusoids into capillaries (in the cases of chronic active hepatitis and cirrhosis which leads to a disorder of microcirculation and further progress of cirrhosis.

  12. Appropriate uptake period for myocardial PET imaging with 18F-FDG after oral glucose loading

    International Nuclear Information System (INIS)

    Brink, I.; Hentschell, M.; Hoegerle, S.; Moser, E.; Nitzsche, E.U.; Mix, M.; Schindler, T.

    2003-01-01

    Aim: Identification of a rationale for the appropriate uptake period for myocardial 18 F-FDG-PET imaging of patients with and without diabetes mellitus. Methods: In a subset of 27 patients, static 2D-PET examination was performed of patients with chronic coronary artery disease and known myocardial infarction. The patients fasted (at least 4 h) before examination. 18 F-FDG (330 ± 20 MBq) was injected intravenously. The image quality was semiquantitativly determined by ROI-analysis and the myocardium-to-blood pool activity ratio (M/B) was calculated. I.) Scans 30, 60, and 90 min p. i. of 10 non-diabetic patients (60 g oral glucose loading one hour before FDG-injection, low-dose intravenous insulin bolus if necessary). II.) Scans 30, 60, and 90 min p. i. of 10 patients with known non-insulin dependent diabetes (20 g glucose, insulin bolus). III.) Scans 90 min p. i. of 7 patients with known non-insulin dependent diabetes and elevated fasting serum glucose level (140-200 mg/dl; insulin bolus, no glucose). Results: I.) The M/B ratio significantly increases in non-diabetic patients with the uptake time (30 min 1.95 ± 0.20; 60 min 2.96 ± 0.36; 90 min 3.78 ± 0.43). II.) In patients with non-insulin dependent diabetes the M/B ratio also significantly increases with uptake time. Compared to non-diabetic patients group II reached smaller M/B values (30 min 1.56 ± 0.10; 60 min 2.15 ± 0.14; 90 min 2.71 ± 0.19). III.) In the group of patients with elevated fasting serum glucose level (who only got insulin but no glucose loading) the M/B activity ratio 90 min p. i. was clearly inferior compared with diabetic patients after oral glucose loading and insulin administration (M/B 2.71 ± 0.19 versus 2.16 ± 0.07). Conclusions: In static myocardial viability PET studies with 18 F-FDG an uptake time of 90 min yields image quality superior to that obtained after shorter uptake time. (orig.) [de

  13. Correlation between blood glucose levels and salivary glucose levels with oral ulcer in diabetic patients

    Directory of Open Access Journals (Sweden)

    Fildzah Rahman

    2016-06-01

    Full Text Available Diabetes Mellitus (DM is a syndrome in metabolism of carbohydrates which indicated by the increased level of blood glucose and also may increase salivary glucose levels. Oral ulcer has been frequently recognized in diabetic patients, which can be due to increased glucose in oral fluids and immune dysfunction. This study aimed to determine the correlation of blood glucose levels and salivary glucose levels with oral ulcer in diabetic patients. Analytic observational study was carried out through the determination of blood glucose levels just by way of strip using a glucometer and salivary glucose levels with the method "GOD-PAP test enzymatic colorimetric". Oral ulcer was determined in presenting ulcer on 30 patients with DM. The results showed r = 0.228, which is higher salivary glucose levels followed by high levels of blood glucose, and intraoral examination of oral ulcer found in the whole sample and the most location commonly found in buccal mucosa and lingual. It was concluded that there is a correlation between blood glucose levels and salivary glucose levels, and glucose levels affect the occurrence of oral ulcer in patients with DM

  14. Secretion, degradation, and elimination of glucagon-like peptide 1 and gastric inhibitory polypeptide in patients with chronic renal insufficiency and healthy control subjects

    DEFF Research Database (Denmark)

    Meier, Juris J; Nauck, Michael A; Kranz, Daniel

    2004-01-01

    occasions, an oral glucose tolerance test (75 g), an intravenous infusion of GLP-1 (0.5 pmol. kg(-1). min(-1) over 30 min), and an intravenous infusion of GIP (1.0 pmol. kg(-1). min(-1) over 30 min) were performed. Venous blood samples were drawn for the determination of glucose (glucose oxidase), insulin......, C-peptide, GLP-1 (total and intact), and GIP (total and intact; specific immunoassays). Plasma levels of GIP (3-42) and GLP-1 (9-36 amide) were calculated. Statistics were performed using repeated-measures and one-way ANOVA. After the oral glucose load, plasma concentrations of intact GLP-1...

  15. Effects of rumen-protected Capsicum oleoresin on productivity and responses to a glucose tolerance test in lactating dairy cows.

    Science.gov (United States)

    Oh, J; Harper, M; Giallongo, F; Bravo, D M; Wall, E H; Hristov, A N

    2017-03-01

    The objective of this experiment was to investigate the effects of rumen-protected Capsicum oleoresin (RPC) supplementation on feed intake, milk yield and composition, nutrient utilization, fecal microbial ecology, and responses to a glucose tolerance test in lactating dairy cows. Nine multiparous Holstein cows were used in a replicated 3 × 3 Latin square design balanced for residual effects with three 28-d periods. Each period consisted of 14 d for adaptation and 14 d for data collection and sampling. Treatments were 0 (control), 100, and 200 mg of RPC/cow per day. They were mixed with a small portion of the total mixed ration and top-dressed. Glucose tolerance test was conducted once during each experimental period by intravenous administration of glucose at a rate of 0.3 g/kg of body weight. Dry matter intake was not affected by RPC. Milk yield tended to increase for RPC treatments compared to the control. Feed efficiency was linearly increased by RPC supplementation. Concentrations of fat, true protein, and lactose in milk were not affected by RPC. Apparent total-tract digestibility of dry matter, organic matter, and crude protein was linearly increased, and fecal nitrogen excretion was linearly decreased by RPC supplementation. Rumen-protected Capsicum oleoresin did not affect the composition of fecal bacteria. Glucose concentration in serum was not affected by RPC supplementation post glucose challenge. However, compared to the control, RPC decreased serum insulin concentration at 5, 10, and 40 min post glucose challenge. The area under the insulin concentration curve was also decreased 25% by RPC. Concentration of nonesterified fatty acids and β-hydroxybutyrate in serum were not affected by RPC following glucose administration. In this study, RPC tended to increase milk production and increased feed efficiency in dairy cows. In addition, RPC decreased serum insulin concentration during the glucose tolerance test, but glucose concentration was not affected

  16. Prediction of Glucose Tolerance without an Oral Glucose Tolerance Test

    Directory of Open Access Journals (Sweden)

    Rohit Babbar

    2018-03-01

    Full Text Available IntroductionImpaired glucose tolerance (IGT is diagnosed by a standardized oral glucose tolerance test (OGTT. However, the OGTT is laborious, and when not performed, glucose tolerance cannot be determined from fasting samples retrospectively. We tested if glucose tolerance status is reasonably predictable from a combination of demographic, anthropometric, and laboratory data assessed at one time point in a fasting state.MethodsGiven a set of 22 variables selected upon clinical feasibility such as sex, age, height, weight, waist circumference, blood pressure, fasting glucose, HbA1c, hemoglobin, mean corpuscular volume, serum potassium, fasting levels of insulin, C-peptide, triglyceride, non-esterified fatty acids (NEFA, proinsulin, prolactin, cholesterol, low-density lipoprotein, HDL, uric acid, liver transaminases, and ferritin, we used supervised machine learning to estimate glucose tolerance status in 2,337 participants of the TUEF study who were recruited before 2012. We tested the performance of 10 different machine learning classifiers on data from 929 participants in the test set who were recruited after 2012. In addition, reproducibility of IGT was analyzed in 78 participants who had 2 repeated OGTTs within 1 year.ResultsThe most accurate prediction of IGT was reached with the recursive partitioning method (accuracy = 0.78. For all classifiers, mean accuracy was 0.73 ± 0.04. The most important model variable was fasting glucose in all models. Using mean variable importance across all models, fasting glucose was followed by NEFA, triglycerides, HbA1c, and C-peptide. The accuracy of predicting IGT from a previous OGTT was 0.77.ConclusionMachine learning methods yield moderate accuracy in predicting glucose tolerance from a wide set of clinical and laboratory variables. A substitution of OGTT does not currently seem to be feasible. An important constraint could be the limited reproducibility of glucose tolerance status during a

  17. Intravenous anaesthesia using detomidine, ketamine and guaiphenesin for laparotomy in pregnant pony mares.

    Science.gov (United States)

    Taylor, Polly M; Luna, Stelio Pl; White, Kate L; Bloomfield, Malcolm; Fowden, Abigail L

    2001-07-01

    Objective To characterize intravenous anaesthesia with detomidine, ketamine and guaiphenesin in pregnant ponies. Animals Twelve pony mares, at 260-320 days gestation undergoing abdominal surgery to implant fetal and maternal vascular catheters. Materials and methods Pre-anaesthetic medication with intravenous (IV) acepromazine (30 µg kg -1 ), butorphanol (20 µg kg -1 ) and detomidine (10 µg kg -1 ) preceded induction of anaesthesia with detomidine (10 µg kg -1 ) and ketamine (2 mg kg -1 ) IV Maternal arterial blood pressure was measured directly throughout anaesthesia and arterial blood samples were taken at 20-minute intervals for measurement of blood gases and plasma concentrations of cortisol, glucose and lactate. Anaesthesia was maintained with an IV infusion of detomidine (0.04 mg mL -1 ), ketamine (4 mg mL -1 ) and guaiphenesin (100 mg mL -1 ) (DKG) for 140 minutes. Oxygen was supplied by intermittent positive pressure ventilation (IPPV) adjusted to maintain PaCO 2 between 5.0 and 6.0 kPa (38 and 45 mm Hg), while PaO 2 was kept close to 20.0 kPa (150 mm Hg) by adding nitrous oxide. Simultaneous fetal and maternal blood samples were withdrawn at 90 minutes. Recovery quality was assessed. Results DKG was infused at 0.67 ± 0.17 mL kg -1 hour -1 for 1 hour then reduced, reaching 0.28 ± 0.14 mL kg -1 hour -1 at 140 minutes. Arterial blood gas values and pH remained within intended limits. During anaesthesia there was no change in heart rate, but arterial blood pressure decreased by 10%. Plasma glucose and lactate increased (10-fold and 2-fold, respectively) and cortisol decreased by 50% during anaesthesia. Fetal umbilical venous pH, PO 2 and PCO 2 were 7.34 ± 0.06, 5.8 ± 0.9 kPa (44 ± 7 mm Hg) and 6.7 ± 0.8 kPa (50 ± 6 mm Hg); and fetal arterial pH, PO 2 and PCO 2 were 7.29 ± 0.06, 4.0 ± 0.7 kPa (30 ± 5 mm Hg) and 7.8 ± 1.7 kPa (59 ± 13 mm Hg), respectively. Surgical conditions were good but four ponies required a single additional dose of ketamine

  18. Blood glucose control in the intensive care unit: benefits and risks.

    Science.gov (United States)

    Gunst, Jan; Van den Berghe, Greet

    2010-01-01

    Abnormal blood glucose levels are common during critical illness and are associated with outcomes that correspond to a J-shaped curve, the lowest risk associated with normoglycemia. Three proof-of-concept randomized-controlled-trials performed in the surgical, medical, and pediatric intensive care units of the Leuven University Hospital in Belgium demonstrated that maintaining strict age-adjusted normal fasting levels of glycemia (80-110 mg/dl in adults, 70-100 mg/dl in children, 50-80 mg/dl in infants) with intensive insulin therapy reduced morbidity and mortality as compared with tolerating stress hyperglycemia as a potentially beneficial response. Recently, concern has risen about the safety of this intervention, as a multicenter adult study reported an, as yet unexplained, increased mortality with targeting normoglycemia as compared with an intermediate blood glucose level of around 140 mg/dl. This apparent contradiction may be explained by several methodological differences among studies, comprising, among others, different glucose target ranges in the control groups, different feeding policies, and variable accuracy of tools used for glucose measurement and insulin infusion. Hence, efficacy and safety of intensive insulin therapy may be affected by patient-related and ICU setting-related variables. Therefore, no single optimal blood glucose target range for ICU patients can be advocated. It appears safe not to embark on targeting "age-normal" levels in intensive care units (ICUs) that are not equipped to accurately and frequently measure blood glucose, and have not acquired extensive experience with intravenous insulin administration using a customized guideline. A simple fallback position could be to control blood glucose levels as close to normal as possible without evoking unacceptable blood glucose fluctuations, hypoglycemia, and hypokalemia.

  19. Quantitative assessment of cerebral glucose metabolic rates after blood-brain barrier disruption induced by focused ultrasound using FDG-MicroPET.

    Science.gov (United States)

    Yang, Feng-Yi; Chang, Wen-Yuan; Chen, Jyh-Cheng; Lee, Lin-Chien; Hung, Yi-Shun

    2014-04-15

    The goal of this study was to evaluate the pharmacokinetics of (18)F-2-fluoro-2-deoxy-d-glucose ((18)F-FDG) and the expression of glucose transporter 1 (GLUT1) protein after blood-brain barrier (BBB) disruption of normal rat brains by focused ultrasound (FUS). After delivery of an intravenous bolus of ~37 MBq (1 mCi) (18)F-FDG, dynamic positron emission tomography scans were performed on rats with normal brains and those whose BBBs had been disrupted by FUS. Arterial blood sampling was collected throughout the scanning procedure. A 2-tissue compartmental model was used to estimate (18)F-FDG kinetic parameters in brain tissues. The rate constants Ki, K1, and k3 were assumed to characterize the uptake, transport, and hexokinase activity, respectively, of (18)F-FDG. The uptake of (18)F-FDG in brains significantly decreased immediately after the blood-brain barrier was disrupted. At the same time, the derived values of Ki, K1, and k3 for the sonicated brains were significantly lower than those for the control brains. In agreement with the reduction in glucose, Western blot analyses confirmed that focused ultrasound exposure significantly reduced the expression of GLUT1 protein in the brains. Furthermore, the effect of focused ultrasound on glucose uptake was transient and reversible 24h after sonication. Our results indicate that focused ultrasound may inhibit GLUT1 expression to decrease the glucose uptake in brain tissue during the period of BBB disruption. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Ultrasonography-guided peripheral intravenous access versus traditional approaches in patients with difficult intravenous access.

    Science.gov (United States)

    Costantino, Thomas G; Parikh, Aman K; Satz, Wayne A; Fojtik, John P

    2005-11-01

    We assess the success rate of emergency physicians in placing peripheral intravenous catheters in difficult-access patients who were unsuccessfully cannulated by emergency nurses. A technique using real-time ultrasonographic guidance by 2 physicians was compared with traditional approaches using palpation and landmark guidance. This was a prospective, systematically allocated study of all patients requiring intravenous access who presented to 2 university hospitals between October 2003 and March 2004. Inclusion criterion was the inability of any available nurse to obtain intravenous access after at least 3 attempts on a subgroup of patients who had a history of difficult intravenous access because of obesity, history of intravenous drug abuse, or chronic medical problems. Exclusion criterion was the need for central venous access. Patients presenting on odd days were allocated to the ultrasonographic-guided group, and those presenting on even days were allocated to the traditional-approach group. Endpoints were successful cannulation, number of sticks, time, and patient satisfaction. Sixty patients were enrolled, 39 on odd days and 21 on even days. Success rate was greater for the ultrasonographic group (97%) versus control (33%), difference in proportions of 64% (95% confidence interval [CI] 39% to 71%). The ultrasonographic group required less overall time (13 minutes versus 30 minutes, for a difference of 17 [95% CI 0.8 to 25.6]), less time to successful cannulation from first percutaneous puncture (4 minutes versus 15 minutes, for a difference of 11 [95% CI 8.2 to 19.4]), and fewer percutaneous punctures (1.7 versus 3.7, for a difference of 2.0 [95% CI 1.27 to 2.82]) and had greater patient satisfaction (8.7 versus 5.7, for a difference of 3.0 [95% CI 1.82 to 4.29]) than the traditional landmark approach. Ultrasonographic-guided peripheral intravenous access is more successful than traditional "blind" techniques, requires less time, decreases the number of

  1. Effects of intranasal insulin on endogenous glucose production in insulin-resistant men.

    Science.gov (United States)

    Xiao, Changting; Dash, Satya; Stahel, Priska; Lewis, Gary F

    2018-03-14

    The effects of intranasal insulin on the regulation of endogenous glucose production (EGP) in individuals with insulin resistance were assessed in a single-blind, crossover study. Overweight or obese insulin-resistant men (n = 7; body mass index 35.4 ± 4.4 kg/m 2 , homeostatic model assessment of insulin resistance 5.6 ± 1.6) received intranasal spray of either 40 IU insulin lispro or placebo in 2 randomized visits. Acute systemic spillover of intranasal insulin into the circulation was matched with a 30-minute intravenous infusion of insulin lispro in the nasal placebo arm. EGP was assessed under conditions of a pancreatic clamp with a primed, constant infusion of glucose tracer. Under these experimental conditions, compared with placebo, intranasal administration of insulin did not significantly affect plasma glucose concentrations, EGP or glucose disposal in overweight/obese, insulin-resistant men, in contrast to our previous study, in which an equivalent dose of intranasal insulin significantly suppressed EGP in lean, insulin-sensitive men. Insulin resistance is probably associated with impairment in centrally mediated insulin suppression of EGP. © 2018 John Wiley & Sons Ltd.

  2. Measuring Blood Glucose Concentrations in Photometric Glucometers Requiring Very Small Sample Volumes.

    Science.gov (United States)

    Demitri, Nevine; Zoubir, Abdelhak M

    2017-01-01

    Glucometers present an important self-monitoring tool for diabetes patients and, therefore, must exhibit high accuracy as well as good usability features. Based on an invasive photometric measurement principle that drastically reduces the volume of the blood sample needed from the patient, we present a framework that is capable of dealing with small blood samples, while maintaining the required accuracy. The framework consists of two major parts: 1) image segmentation; and 2) convergence detection. Step 1 is based on iterative mode-seeking methods to estimate the intensity value of the region of interest. We present several variations of these methods and give theoretical proofs of their convergence. Our approach is able to deal with changes in the number and position of clusters without any prior knowledge. Furthermore, we propose a method based on sparse approximation to decrease the computational load, while maintaining accuracy. Step 2 is achieved by employing temporal tracking and prediction, herewith decreasing the measurement time, and, thus, improving usability. Our framework is tested on several real datasets with different characteristics. We show that we are able to estimate the underlying glucose concentration from much smaller blood samples than is currently state of the art with sufficient accuracy according to the most recent ISO standards and reduce measurement time significantly compared to state-of-the-art methods.

  3. The effect of different treatments for early-lactation hyperketonemia on blood β-hydroxybutyrate, plasma nonesterified fatty acids, glucose, insulin, and glucagon in dairy cattle.

    Science.gov (United States)

    Mann, S; Yepes, F A Leal; Behling-Kelly, E; McArt, J A A

    2017-08-01

    Despite increased efforts in preventing the occurrence of metabolic disorders in transition cows, hyperketonemia remains a frequent early-lactation metabolic disease affecting an average of 40% of cows in herds in the United States. Despite the demonstrated economic effect of this disorder, controlled clinical trials comparing different treatment strategies in affected cows are lacking. The objective of our study was to investigate the effect of treatment with intravenous glucose, oral propylene glycol, or a combination of both on the reduction in blood β-hydroxybutyrate (BHB) concentrations of early-lactation hyperketonemic dairy cows. Multiparous Holstein cows between 3 to 9 d in milk were screened for hyperketonemia using a handheld meter 3 times per week, and enrolled at whole blood BHB concentration ≥1.2 mmol/L to 1 of 4 treatment groups: (1) 500 mL of a 50% dextrose solution i.v. once daily for 3 d (GLU, n = 9), (2) 300 mL of propylene glycol as a drench once daily for 3 d (PG, n = 9), (3) a combination treatment of a 500 mL of 50% dextrose solution i.v. and 300 mL of propylene glycol orally once daily for 3 d (GLU+PG, n = 8), or (4) an untreated control group (CTRL, n = 8). Blood samples were collected immediately before as well as at 1, 2, 4, 8, 12, 24, 36, 48, 60, and 72 h after administration of the first treatment through a jugular catheter and 3 times per week thereafter from coccygeal vessels. Concentrations of BHB were measured in whole blood, and plasma samples were analyzed for glucose, fatty acid (NEFA), insulin, glucagon, and electrolyte concentrations. The EDTA-anticoagulated blood samples were assessed for red blood cell indices, and smears were made for evaluation of red blood cell morphology. Outcomes were analyzed using repeated measures analysis. Overall least squares means (95% CI) of whole blood BHB concentrations between 1 h and d 11 relative to first treatment were 1.11 (0.95 to 1.30), 1.26 (1.07 to 1.47), 0.96 (0.81 to 1.13), and 1

  4. Short-Term Estrogen Replacement Effects on Insulin Sensitivity and Glucose Tolerance in At-Risk Cats for Feline Diabetes Mellitus.

    Directory of Open Access Journals (Sweden)

    Allison Wara

    Full Text Available Male domestic cats that are neutered and overweight are at an increased risk for developing a type-2-like diabetes mellitus. Beneficial effects of 17β-estradiol (E2 on glucose homeostasis may be lost with neutering and thereby account for increased diabetes risk. To evaluate this, adult male neutered overweight cats (n=6 were given daily E2 (1.0 μg/kg or vehicle (Vh; ethanol, 1.0 μL/kg in a single crossover trial of 14-day periods with a 7-day washout. The E2 and Vh were voluntarily ingested on food. The E2 dosage was determined in a pre-trial to significantly and transiently reduce food intake with no measurable change in plasma E2 concentration. During treatments, physical activity was assessed with collar-mounted accelerometers on days 9-11, and tests of intravenous insulin tolerance and intravenous glucose tolerance were conducted on days 13 and 14, respectively. Over the 14 days, E2 compared to Vh treatment reduced (p=0.03 food intake (- 22% but not enough to significantly reduce body weight; activity counts were not significantly changed. With E2 compared to Vh treatment, the late-phase plasma insulin response of the glucose tolerance test was less (p=0.03 by 31%, while glucose tolerance and insulin sensitivity indexes were not significantly changed. The results indicate that oral E2 at a dosage that moderately affects food intake may reduce insulin requirement for achieving glucose homeostasis in neutered male cats. Further investigation is needed to identify the mechanism underlying the E2 effect.

  5. Nanomaterials in glucose sensing

    CERN Document Server

    Burugapalli, Krishna

    2013-01-01

    The smartness of nano-materials is attributed to their nanoscale and subsequently unique physicochemical properties and their use in glucose sensing has been aimed at improving performance, reducing cost and miniaturizing the sensor and its associated instrumentation. So far, portable (handheld) glucose analysers were introduced for hospital wards, emergency rooms and physicians' offices; single-use strip systems achieved nanolitre sampling for painless and accurate home glucose monitoring; advanced continuous monitoring devices having 2 to 7 days operating life are in clinical and home use; and continued research efforts are being made to develop and introduce increasingly advanced glucose monitoring systems for health as well as food, biotechnology, cell and tissue culture industries. Nanomaterials have touched every aspect of biosensor design and this chapter reviews their role in the development of advanced technologies for glucose sensing, and especially for diabetes. Research shows that overall, nanomat...

  6. Intravenous Therapy: Hazards, Complications and Their Prevention ...

    African Journals Online (AJOL)

    Breaks in aseptic techniques, faulty handling of parenteral fluid containers, failure to discard out-dated intravenous solutions and tubings contribute to occurrence of intravenous-associated sepsis. Improper technique and lack of pharmaceutical knowledge when adding drugs into intravenous fluids contribute to ...

  7. Effect of diet on insulin binding and glucose transport in rat sarcolemmal vesicles

    International Nuclear Information System (INIS)

    Grimditch, G.K.; Barnard, R.J.; Sternlicht, E.; Whitson, R.H.; Kaplan, S.A.

    1987-01-01

    The purpose of this study was to compare the effects of a high-fat, high-sucrose diet (HFS) and a low-fat, high-complex carbohydrate diet (LFC) on glucose tolerance, insulin binding, and glucose transport in rat skeletal muscle. During the intravenous glucose tolerance test, peak glucose values at 5 min were significantly higher in the HFS group; 0-, 20-, and 60-min values were similar. Insulin values were significantly higher in the HFS group at all time points (except 60 min), indicating whole-body insulin resistance. Skeletal muscle was responsible, in part, for this insulin resistance, because specific D-glucose transport in isolated sarcolemmal (SL) vesicles under basal conditions was similar between LFC and HFS rats, despite the higher plasma insulin levels. Scatchard analyses of insulin binding curves to sarcolemmal vesicles revealed that the K/sub a/ of the high-affinity binding sites was significantly reduced by the HFS diet; no other binding changes were noted. Specific D-glucose transport in SL vesicles after maximum insulin stimulation (1 U/kg) was significantly depressed in the HFS group, indicating that HFS feeding also caused a postbinding defect. These results indicate that the insulin resistance in skeletal muscle associated with a HFS diet is due to both a decrease in the K/sub a/ of the high-affinity insulin receptors and a postbinding defect

  8. Compatibility of intravenous ibuprofen with lipids and parenteral nutrition, for use as a continuous infusion.

    Science.gov (United States)

    Garcia, Jowell; Garg, Alka; Song, Yunmei; Fotios, Ambados; Andersen, Chad; Garg, Sanjay

    2018-01-01

    There is increasing interest to administer ibuprofen as a continuous infusion instead of a traditional bolus for treating Patent Ductus Arteriosus (PDA). However, its compatibility data with commonly used drugs in the neonatal period, including parenteral nutrition (PN) and lipids is unavailable. The aim is to determine the compatibility of intravenous ibuprofen lysine with various ANZNN parenteral nutrition consensus group standard neonatal PN formulations and lipids. The PN and lipid solutions used in a tertiary neonatal unit were obtained. These included a Starter, Standard Preterm and low carbohydrate PN, and IV SMOF lipid admixture (SMOFLipid 20% 15 mL; Vitalipid N infant 4 mL, Soluvit N 1 mL) plus vitamin mixtures. 10% glucose was used as a control. 1:1 mixtures of different concentrations (1.25 to 5mg/mL) of ibuprofen lysine and each of the PN/glucose/lipid formulations were made. Samples were taken at hourly intervals for a total of 4 hours and tested for both physical (visual assessment, pH and microscopy) and chemical compatibility (High Performance Liquid Chromatography analysis). Zeta potential and particle diameter were measured for SMOF lipid admixture and ibuprofen combination to assess emulsion stability. 24 hour stability of ibuprofen dilution in 5 mL BD Luer-lok polypropylene syringes at 25°C was also assessed. Most PN formed opaque solutions when mixed with ibuprofen 2.5 and 5mg/mL solutions. However, ibuprofen dilution of 1.25mg/mL produced clear, colourless solutions with no microscopic particles when mixed with all PN/glucose/lipid formulations tested. Ibuprofen was chemically stable with all PN and SMOF lipid admixture, for a period of 4 hours. The zeta potential and particle diameter were within acceptable limits. Ibuprofen lysine was stable over 24 hours in Luer-lok polypropylene syringes. Ibuprofen 1.25mg/mL is physically and chemically compatible with 10% glucose, starter PN, standard preterm and low carbohydrate PN, and SMOF lipid

  9. Cutpoints for screening blood glucose concentrations in healthy senior cats.

    Science.gov (United States)

    Reeve-Johnson, Mia K; Rand, Jacquie S; Vankan, Dianne; Anderson, Stephen T; Marshall, Rhett; Morton, John M

    2017-12-01

    Objectives The objectives of this study were to determine the reference interval for screening blood glucose in senior cats, to apply this to a population of obese senior cats, to compare screening and fasting blood glucose, to assess whether screening blood glucose is predicted by breed, body weight, body condition score (BCS), behaviour score, fasting blood glucose and/or recent carbohydrate intake and to assess its robustness to changes in methodology. Methods The study included a total of 120 clinically healthy client-owned cats aged 8 years and older of varying breeds and BCSs. Blood glucose was measured at the beginning of the consultation from an ear/paw sample using a portable glucose meter calibrated for cats, and again after physical examination from a jugular sample. Fasting blood glucose was measured after overnight hospitalisation and fasting for 18-24 h. Results The reference interval upper limit for screening blood glucose was 189 mg/dl (10.5 mmol/l). Mean screening blood glucose was greater than mean fasting glucose. Breed, body weight, BCS, behaviour score, fasting blood glucose concentration and amount of carbohydrate consumed 2-24 h before sampling collectively explained only a small proportion of the variability in screening blood glucose. Conclusions and relevance Screening blood glucose measurement represents a simple test, and cats with values from 117-189 mg/dl (6.5-10.5 mmol/l) should be retested several hours later. Cats with initial screening blood glucose >189 mg/dl (10.5 mmol/l), or a second screening blood glucose >116 mg/dl (6.4 mmol/l) several hours after the first, should have fasting glucose and glucose tolerance measured after overnight hospitalisation.

  10. Conjoint regulation of glucagon concentrations via plasma insulin and glucose in dairy cows.

    Science.gov (United States)

    Zarrin, M; Wellnitz, O; Bruckmaier, R M

    2015-04-01

    Insulin and glucagon are glucoregulatory hormones that contribute to glucose homeostasis. Plasma insulin is elevated during normoglycemia or hyperglycemia and acts as a suppressor of glucagon secretion. We have investigated if and how insulin and glucose contribute to the regulation of glucagon secretion through long term (48 h) elevated insulin concentrations during simultaneous hypoglycemia or euglycemia in mid-lactating dairy cows. Nineteen Holstein dairy cows were randomly assigned to 3 treatment groups: an intravenous insulin infusion (HypoG, n = 5) to decrease plasma glucose concentrations (2.5 mmol/L), a hyperinsulinemic-euglycemic clamp to study effects of insulin at simultaneously normal glucose concentrations (EuG, n = 6) and a 0.9% saline infusion (NaCl, n = 8). Plasma glucose was measured at 5-min intervals, and insulin and glucose infusion rates were adjusted accordingly. Area under the curve of hourly glucose, insulin, and glucagon concentrations on day 2 of infusion was evaluated by analysis of variance with treatments as fixed effect. Insulin infusion caused an increase of plasma insulin area under the curve (AUC)/h in HypoG (41.9 ± 8.1 mU/L) and EuG (57.8 ± 7.8 mU/L) compared with NaCl (13.9 ± 1.1 mU/L; P insulin infusion induces elevated glucagon concentrations during hypoglycemia, although the same insulin infusion reduces glucagon concentrations at simultaneously normal glucose concentrations. Thus, insulin does not generally have an inhibitory effect on glucagon concentrations. If simultaneously glucose is low and insulin is high, glucagon is upregulated to increase glucose availability. Therefore, insulin and glucose are conjoint regulatory factors of glucagon concentrations in dairy cows, and the plasma glucose status is the key factor to decide if its concentrations are increased or decreased. This regulatory effect can be important for the maintenance of glucose homeostasis if insulin secretion is upregulated by other factors than high

  11. INTRAVENOUS IMMUNOGLOBULIN IN PEDIATRIC RHEUMATOLOGY PRACTICE

    Directory of Open Access Journals (Sweden)

    E. I. Alexeeva

    2015-01-01

    Full Text Available Modern successful treatment of rheumatic diseases is impossible without the use of intravenous immunoglobulin. The use of intravenous immunoglobulin is based on strict indications developed as a result of long-term multicenter controlled studies. The article highlights the issues of using immunoglobulin in pediatric rheumatology practice, and provides the review of literature with the results from the evaluation of the efficiency of intravenous immunoglobulin confirming the efficiency of the drug only for certain rheumatic diseases. 

  12. Exenatide improves glucocorticoid-induced glucose intolerance in mice

    Directory of Open Access Journals (Sweden)

    Ruiying Zhao

    2011-01-01

    Full Text Available Ruiying Zhao1,2*, Enrique Fuentes-Mattei1,2*, Guermarie Velazquez-Torres1,3, Chun-Hui Su1,2, Jian Chen1, Mong-Hong Lee1,2, Sai-Ching Jim Yeung4,51Department of Molecular and Cellular Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, USA; 2Program in Genes and Development, 3Program in Cancer Biology, Graduate School of Biomedical Sciences, University of Texas Health Science Center in Houston, Houston, TX, USA; 4Department of Endocrine Neoplasia and Hormonal Disorders, 5Department of Emergency Medicine, University of Texas MD Anderson Cancer Center, Houston, TX, USA *Both authors contributed equally.Abstract: Exenatide is an incretin mimetic that is recently available in the US for the treatment of diabetes. There is a paucity of information on the effects of exenatide in glucocorticoid (GC-induced diabetes. Although the effect of continuous intravenous infusion of exenatide on GC-induced glucose intolerance has been investigated before in healthy human males receiving oral prednisolone, we investigated the efficacy of a single subcutaneous dose of exenatide (3 µg/kg in lowering blood glucose in GC-induced glucose intolerance in C57BL/6 mice. In a longitudinal experiment, the area under the curve (AUC of oral glucose tolerance tests (OGTT significantly increased after dexamethasone (P = 0.004, which was subsequently decreased by exenatide (P < 0.001. A cross-sectional experiment showed that exenatide improved glucose tolerance compared with placebo in a mouse model of dexamethasone-induced glucose intolerance. AUC of OGTT in the exenatide group were significantly (P < 0.001 lower than in the placebo group. Insulin tolerance tests (ITT demonstrated that exenatide decreased the ability of the mice to tolerate insulin compared with placebo. The AUC of ITT in the exenatide group were also significantly (P = 0.006 lower than in the placebo group. In conclusion, a single dose of exenatide was able to decrease glucose intolerance and

  13. Comparison of two blood sampling techniques for the determination of coagulation parameters in the horse: Jugular venipuncture and indwelling intravenous catheter.

    Science.gov (United States)

    Mackenzie, C J; McGowan, C M; Pinchbeck, G; Carslake, H B

    2018-05-01

    Evaluation of coagulation status is an important component of critical care. Ongoing monitoring of coagulation status in hospitalised horses has previously been via serial venipuncture due to concerns that sampling directly from the intravenous catheter (IVC) may alter the accuracy of the results. Adverse effects such as patient anxiety and trauma to the sampled vessel could be avoided by the use of an indwelling IVC for repeat blood sampling. To compare coagulation parameters from blood obtained by jugular venipuncture with IVC sampling in critically ill horses. Prospective observational study. A single set of paired blood samples were obtained from horses (n = 55) admitted to an intensive care unit by direct jugular venipuncture and, following removal of a presample, via an indwelling IVC. The following coagulation parameters were measured on venipuncture and IVC samples: whole blood prothrombin time (PT), fresh plasma PT and activated partial thromboplastin time (aPTT) and stored plasma antithrombin activity (AT) and fibrinogen concentration. D-dimer concentration was also measured in some horses (n = 22). Comparison of venipuncture and IVC results was performed using Lin's concordance correlation coefficient. Agreement between paired results was assessed using Bland Altman analysis. Correlation was substantial and agreement was good between sample methods for all parameters except AT and D-dimers. Each coagulation parameter was tested using only one assay. Sampling was limited to a convenience sample and timing of sample collection was not standardised in relation to when the catheter was flushed with heparinised saline. With the exception of AT and D-dimers, coagulation parameters measured on blood samples obtained via an IVC have clinically equivalent values to those obtained by jugular venipuncture. © 2017 EVJ Ltd.

  14. Verification of intravenous catheter placement by auscultation--a simple, noninvasive technique.

    Science.gov (United States)

    Lehavi, Amit; Rudich, Utay; Schechtman, Moshe; Katz, Yeshayahu Shai

    2014-01-01

    Verification of proper placement of an intravenous catheter may not always be simple. We evaluated the auscultation technique for this purpose. Twenty healthy volunteers were randomized for 18G catheter inserted intravenously either in the right (12) or left arm (8), and subcutaneously in the opposite arm. A standard stethoscope was placed over an area approximately 3 cm proximal to the tip of the catheter in the presumed direction of the vein to grade on a 0-6 scale the murmur heard by rapidly injecting 2 mL of NaCl 0.9% solution. The auscultation was evaluated by a blinded staff anesthesiologist. All 20 intravenous injection were evaluated as flow murmurs, and were graded an average 5.65 (±0.98), whereas all 20 subcutaneous injections were evaluated as either crackles or no sound, and were graded an average 2.00 (±1.38), without negative results. Sensitivity was calculated as 95%. Specificity and Kappa could not be calculated due to an empty false-positive group. Being simple, handy and noninvasive, we recommend to use the auscultation technique for verification of the proper placement of an intravenous catheter when uncertain of its position. Data obtained in our limited sample of healthy subjects need to be confirmed in the clinical setting.

  15. The effects of short term intravenous infusion of a soybean based lipid emulsion on some blood constituents in sheep: A preliminary study

    Directory of Open Access Journals (Sweden)

    Hamid Akbari

    2014-04-01

    Full Text Available To evaluate the effect of intravenous infusion of a soybean based lipid emulsion (Lipovenoes 10% on some blood constituents in sheep, a replicated 2 × 2 Latin square design experiment was conducted in four clinically healthy ewes. Lipid emulsion (LE group or normal saline (NS group was infused intravenously at a rate of 0.025 mL kg-1 per min for 6 hr and the concentrations of blood triglyceride, glucose, insulin, calcium, magnesium, phosphorous, sodium and potassium were measured before (baseline and then at timepoints 2, 4, 6, 12 and 24 hr after infusion. Compared to the baseline values and/or NS infusion, LE infusion resulted in a significant increase in the concentrations of triglyceride (p 0.05. In conclusion, intravenous infusion of Lipovenoes temporarily influenced some blood constituents. Increased triglyceride concentrations were associated with an increase in HOMA-IR values indicating a state of insulin resistance. No remarkable adverse effect was observed following LE infusion and lipid based emulsions can be safely used in ruminants not suffering from extensive lipid mobilization.

  16. Underestimation of glucose turnover corrected with high-performance liquid chromatography purification of [6-3H]glucose

    International Nuclear Information System (INIS)

    Schwenk, W.F.; Butler, P.C.; Haymond, M.W.; Rizza, R.A.

    1990-01-01

    We have recently reported that during infusion of commercially available [6-3H]glucose, a radioactive nonglucose contaminant may accumulate in plasma causing errors in the measurement of glucose turnover. To determine whether purification of this tracer by HPLC (high-performance liquid chromatography) before infusion would eliminate the contaminant in plasma and remove the underestimation of glucose turnover reported during hyperinsulinemia, four normal subjects each underwent two 5-h euglycemic clamps during infusion of insulin (1 mU.kg-1.min-1). Glucose turnover was measured with either commercially available [6-3H]glucose or with HPLC-purified [6-3H]glucose. HPLC analysis of samples from the clamps done with commercially available [6-3H]glucose showed that 9.7% of the infused tracer and 26% of the plasma glucose 3H radioactivity were contaminants. In contrast, no contaminant was observed in the plasma during infusion of HPLC-purified [6-3H]glucose. During the last hour of the clamp, mean glucose turnover using commercially available [6-3H]glucose was less (P less than 0.01) than the mean glucose infusion rate (7.6 +/- 0.3 vs. 10.5 +/- 0.3 mg.kg-1.min-1) yielding apparent negative (P less than 0.001) hepatic glucose release. In contrast, when HPLC-purified [6-3H]glucose was employed, glucose turnover equaled the glucose infusion rate (10.4 +/- 0.9 vs. 10.2 +/- 0.9 mg.kg-1.min-1) and hepatic glucose release was no longer negative. We conclude that removal of a tritiated nonglucose contaminant in [6-3H]glucose by HPLC yields correct estimations of glucose turnover at steady state

  17. The post-occipital spinal venous sinus of the Nile crocodile (Crocodylus niloticus: Its anatomy and use for blood sample collection and intravenous infusions

    Directory of Open Access Journals (Sweden)

    Jan G. Myburgh

    2014-05-01

    Full Text Available The post-occipital sinus of the spinal vein is often used for the collection of blood samples from crocodilians. Although this sampling method has been reported for several crocodilian species, the technique and associated anatomy has not been described in detail in any crocodilian, including the Nile crocodile (Crocodylus niloticus. The anatomy of the cranial neck region was investigated macroscopically, microscopically, radiographically and by means of computed tomography. Latex was injected into the spinal vein and spinal venous sinus of crocodiles to visualise the regional vasculature. The spinal vein ran within the vertebral canal, dorsal to and closely associated with the spinal cord and changed into a venous sinus cranially in the post-occipital region. For blood collection, the spinal venous sinus was accessed through the interarcuate space between the atlas and axis (C1 and C2 by inserting a needle angled just off the perpendicular in the midline through the craniodorsal cervical skin, just cranial to the cranial borders of the first cervical osteoderms. The most convenient method of blood collection was with a syringe and hypodermic needle. In addition, the suitability of the spinal venous sinus for intravenous injections and infusions in live crocodiles was evaluated. The internal diameter of the commercial human epidural catheters used during these investigations was relatively small, resulting in very slow infusion rates. Care should be taken not to puncture the spinal cord or to lacerate the blood vessel wall using this route for blood collection or intravenous infusions.

  18. Novel glucose biosensor based on a glassy carbon electrode modified with hollow gold nanoparticles and glucose oxidase

    International Nuclear Information System (INIS)

    Wang, W.; Ying, S.; Zhang, Z.; Huang, S.

    2011-01-01

    A novel glucose biosensor is presented as that based on a glassy carbon electrode modified with hollow gold nanoparticles (HGNs) and glucose oxidase. The sensor exhibits a better differential pulse voltammetric response towards glucose than the one based on conventional gold nanoparticles of the same size. This is attributed to the good biological conductivity and biocompatibility of HGNs. Under the optimal conditions, the sensor displays a linear range from 2.0 x 10 -6 to 4.6 x 10 -5 M of glucose, with a detection limit of 1.6 x 10 -6 M (S/N = 3). Good reproducibility, stability and no interference make this biosensor applicable to the determination of glucose in samples such as sports drinks. (author)

  19. Pharmacokinetics of oral and intravenous melatonin in healthy volunteers

    DEFF Research Database (Denmark)

    Andersen, Lars Peter Holst; Werner, Mads Utke; Rosenkilde, Mette Marie

    2016-01-01

    BACKGROUND: The aim was to investigate the pharmacokinetics of oral and iv melatonin in healthy volunteers. METHODS: The study was performed as a cohort crossover study. The volunteers received either 10 mg oral melatonin or 10 mg intravenous melatonin on two separate study days. Blood samples were...... collected at different time points following oral administration and short iv infusion, respectively. Plasma melatonin concentrations were determined by RIA technique. Pharmacokinetic analyses were performed by "the method of residuals" and compartmental analysis. The pharmacokinetic variables: k a, t 1....../2 absorption, t max, C max, t 1/2 elimination, AUC 0-∞, and bioavailability were determined for oral melatonin. C max, t 1/2 elimination, V d, CL and AUC 0-∞ were determined for intravenous melatonin. RESULTS: Twelve male volunteers completed the study. Baseline melatonin plasma levels did not differ...

  20. In polycystic ovary syndrome, adrenal steroids are regulated differently in the morning versus in response to nutrient intake

    Science.gov (United States)

    The objective of this study was to investigate adrenal steroid regulation in Polycystic Ovary Syndrome (PCOS). A 5-h oral glucose tolerance test (OGTT) and a 3-h frequently sampled-intravenous glucose tolerance test (FSIVGTT) were administered to 30 patients with PCOS. Anthropometric parameters (hei...

  1. The Acute Effects of Low-Dose TNF-α on Glucose Metabolism and β-Cell Function in Humans

    DEFF Research Database (Denmark)

    Ibfelt, Tobias; Fischer, Christian Philip; Plomgaard, Peter

    2014-01-01

    , nondiabetic young men (n = 10) during a 4-hour basal period followed by an intravenous glucose tolerance test (IVGTT). TNF-α lowered insulin levels by 12% during the basal period (P levels increased markedly in both trials, but there was no difference between trials......Type 2 diabetes is characterized by increased insulin resistance and impaired insulin secretion. Type 2 diabetes is also associated with low-grade inflammation and increased levels of proinflammatory cytokines such as TNF-α. TNF-α has been shown to impair peripheral insulin signaling in vitro...... and in vivo. However, it is unclear whether TNF-α may also affect endogenous glucose production (EGP) during fasting and glucose-stimulated insulin secretion (GSIS) in vivo. We hypothesized that low-dose TNF- α would increase EGP and attenuate GSIS. Recombinant human TNF-α or placebo was infused in healthy...

  2. Long-term stability of glucose: glycolysis inhibitor vs. gel barrier tubes.

    Science.gov (United States)

    Winter, Theresa; Hannemann, Anke; Suchsland, Juliane; Nauck, Matthias; Petersmann, Astrid

    2018-03-12

    Measuring the glucose concentration in whole blood samples is critical due to unsatisfactory glycolysis inhibition. Previous studies showed that Terumo tubes were superior, but they were taken off the European market in 2016 and alternatives were required. This initiated the present evaluation of glucose stability in five available tube types. Venous blood samples were collected from 61 healthy volunteers to test tubes supplied by Terumo (two sets), Greiner FC-Mix, BD FX-Mixture and BD serum. After sampling, the contents were thoroughly mixed and centrifuged within an hour. The glucose concentrations were determined and the samples resuspended except for BD serum tubes (gel barrier). The first 30 samples were stored at room temperature and the remaining 31 at 4°C. After 24, 48, 72 and 96 h, all tubes were (re)centrifuged, and glucose concentration measurements were repeated. Changes in glucose concentrations over time differed significantly between the investigated tube types and to a certain extent between the two storing conditions. Glycolysis was most evident in the BD FX-mixture tubes. Good glucose stability was observed in samples retrieved form BD serum and Greiner tubes. The stability in both Terumo tubes was comparable to that in other studies. Although Greiner and both Terumo tubes are supposed to contain the same glycolysis inhibitor, glucose stability differed between these tubes. We showed that Greiner is an acceptable alternative to Terumo and that glucose in serum that was rapidly separated from corpuscles by a gel barrier is stable for an extended time.

  3. Pharmacokinetics of Oral and Intravenous Paracetamol (Acetaminophen) When Co-Administered with Intravenous Morphine in Healthy Adult Subjects.

    Science.gov (United States)

    Raffa, Robert B; Pawasauskas, Jayne; Pergolizzi, Joseph V; Lu, Luke; Chen, Yin; Wu, Sutan; Jarrett, Brant; Fain, Randi; Hill, Lawrence; Devarakonda, Krishna

    2018-03-01

    Several features favor paracetamol (acetaminophen) administration by the intravenous rather than the oral route in the postoperative setting. This study compared the pharmacokinetics and bioavailability of oral and intravenous paracetamol when given with or without an opioid, morphine. In this randomized, single-blind, parallel, repeat-dose study in healthy adults, subjects received four repeat doses of oral or intravenous 1000 mg paracetamol at 6-h intervals, and morphine infusions (0.125 mg/kg) at the 2nd and 3rd intervals. Comparisons of plasma pharmacokinetic profiles were conducted before, during, and after opioid co-administrations. Twenty-two subjects were included in the pharmacokinetic analysis. Observed paracetamol peak concentration (C max ) and area under the plasma concentration-time curve over the dosing interval (AUC 0-6 ) were reduced when oral paracetamol was co-administered with morphine (reduced from 11.6 to 7.25 µg/mL and from 31.00 to 25.51 µg·h/mL, respectively), followed by an abruptly increased C max and AUC 0-6 upon discontinuation of morphine (to 13.5 µg/mL and 52.38 µg·h/mL, respectively). There was also a significantly prolonged mean time to peak plasma concentration (T max ) after the 4th dose of oral paracetamol (2.84 h) compared to the 1st dose (1.48 h). However, pharmacokinetic parameters of paracetamol were not impacted when intravenous paracetamol was co-administered with morphine. Morphine co-administration significantly impacted the pharmacokinetics of oral but not intravenous paracetamol. The abrupt release of accumulated paracetamol at the end of morphine-mediated gastrointestinal inhibition following oral but not intravenous administration of paracetamol suggests that intravenous paracetamol provides a better option for the management of postoperative pain. CLINICALTRIALS. NCT02848729.

  4. Long-term blood glucose monitoring with implanted telemetry device in conscious and stress-free cynomolgus monkeys.

    Science.gov (United States)

    Wang, B; Sun, G; Qiao, W; Liu, Y; Qiao, J; Ye, W; Wang, H; Wang, X; Lindquist, R; Wang, Y; Xiao, Y-F

    2017-09-01

    Continuous blood glucose monitoring, especially long-term and remote, in diabetic patients or research is very challenging. Nonhuman primate (NHP) is an excellent model for metabolic research, because NHPs can naturally develop Type 2 diabetes mellitus (T2DM) similarly to humans. This study was to investigate blood glucose changes in conscious, moving-free cynomolgus monkeys (Macaca fascicularis) during circadian, meal, stress and drug exposure. Blood glucose, body temperature and physical activities were continuously and simultaneously recorded by implanted HD-XG telemetry device for up to 10 weeks. Blood glucose circadian changes in normoglycemic monkeys significantly differed from that in diabetic animals. Postprandial glucose increase was more obvious after afternoon feeding. Moving a monkey from its housing cage to monkey chair increased blood glucose by 30% in both normoglycemic and diabetic monkeys. Such increase in blood glucose declined to the pre-procedure level in 30 min in normoglycemic animals and >2 h in diabetic monkeys. Oral gavage procedure alone caused hyperglycemia in both normoglycemic and diabetic monkeys. Intravenous injection with the stress hormones, angiotensin II (2 μg/kg) or norepinephrine (0.4 μg/kg), also increased blood glucose level by 30%. The glucose levels measured by the telemetry system correlated significantly well with glucometer readings during glucose tolerance tests (ivGTT or oGTT), insulin tolerance test (ITT), graded glucose infusion (GGI) and clamp. Our data demonstrate that the real-time telemetry method is reliable for monitoring blood glucose remotely and continuously in conscious, stress-free, and moving-free NHPs with the advantages highly valuable to diabetes research and drug discovery.

  5. The effect of glucagon-like peptide I (GLP-I) on glucose elimination in healthy subjects depends on the pancreatic glucoregulatory hormones

    DEFF Research Database (Denmark)

    Toft-Nielson, M; Madsbad, Sten; Holst, J J

    1996-01-01

    Glucagon-like peptide I (GLP-I) decreases plasma glucose in type II diabetic patients and in healthy subjects indirectly by stimulation of insulin and inhibition of glucagon secretion, whereby the hepatic glucose production decreases. However, recent studies indicate that GLP-I may also directly...... min, a 25-g intravenous glucose tolerance test (IVGTT) was carried out, and plasma concentrations of glucose, insulin, glucagon, and GLP-I were measured during the following 2 h. IVGTT together with GLP-I infusion significantly elevated insulin during 500 microgram/h SS but not during 1,000 microgram....../h SS. Plasma glucagon was strongly depressed in all experiments. During 500 microgram/h SS, the glucose disappearance constant, Kg, was 0.49 +/- 0.03% per minute with GLP-I and 0.39 +/- 0.04% per minute with saline (n = 8, P = 0.004). With 1,000 microgram/h SS, Kg was 0.42 +/- 0.03% per minute with GLP...

  6. The effect of intraoperative administration of dexamethasone for PONV prophylaxis on perioperative blood glucose level in obese and normal weight children.

    Science.gov (United States)

    Gnatzy, Richard; Hempel, Gunther; Kaisers, Udo X; Höhne, Claudia

    2015-11-01

    The incidence of postoperative nausea and vomiting (PONV) can be reduced by dexamethasone. Single-dose administration may cause elevated blood glucose levels in obese adults. No data are available for children. The aim was to evaluate perioperative blood glucose changes related to body weight in children who received dexamethasone. This prospective observational study included 62 children. All patients received total intravenous anesthesia and a single dose of dexamethasone (0.15 mg/kg, maximum 8 mg). Blood glucose levels were measured up to 6 h. Standard deviation scores (SDS) were calculated using age- and gender-specific body mass index (BMI) percentiles, pBlood glucose levels increased from 5.52±0.52 to 6.74±0.84 mmol/L 6 h after dexamethasone without correlation to the BMI-SDS. This study showed an increase of perioperative blood glucose (normoglycemic ranges) after single dose of dexamethasone, but no BMI-dependent effect was observed in children. Therefore, low-dose dexamethasone may be used in obese children for PONV prophylaxis.

  7. Coexistence of insulin resistance and increased glucose tolerance in pregnant rats: a physiological mechanism for glucose maintenance.

    Science.gov (United States)

    Carrara, Marcia Aparecida; Batista, Márcia Regina; Saruhashi, Tiago Ribeiro; Felisberto, Antonio Machado; Guilhermetti, Marcio; Bazotte, Roberto Barbosa

    2012-06-06

    The contribution of insulin resistance (IR) and glucose tolerance to the maintenance of blood glucose levels in non diabetic pregnant Wistar rats (PWR) was investigated. PWR were submitted to conventional insulin tolerance test (ITT) and glucose tolerance test (GTT) using blood sample collected 0, 10 and 60 min after intraperitoneal insulin (1 U/kg) or oral (gavage) glucose (1g/kg) administration. Moreover, ITT, GTT and the kinetics of glucose concentration changes in the fed and fasted states were evaluated with a real-time continuous glucose monitoring system (RT-CGMS) technique. Furthermore, the contribution of the liver glucose production was investigated. Conventional ITT and GTT at 0, 7, 14 and 20 days of pregnancy revealed increased IR and glucose tolerance after 20 days of pregnancy. Thus, this period of pregnancy was used to investigate the kinetics of glucose changes with the RT-CGMS technique. PWR (day 20) exhibited a lower (pinsulin sensitivity and/or glucose tolerance during late pregnancy. In contrast to the general view that IR is a pathological process associated with gestational diabetes, a certain degree of IR may represent an important physiological mechanism for blood glucose maintenance during fasting. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. GCMS/MS Analyses of Biological Samples in Support of Evaluation of Toxicity Associated with Intravenous Exposure to VX Stereoisomers in Guinea Pigs

    Science.gov (United States)

    2017-07-01

    ASSOCIATED WITH INTRAVENOUS EXPOSURE TO VX STEREOISOMERS IN GUINEA PIGS ECBC-TR-1465 Disclaimer The findings in this report are not to be...VX Stereoisomers in Guinea Pigs 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) McGuire, Jeffrey M.; Wright...lung, liver, kidney, and brain) that were obtained from guinea pigs intravenously exposed to various concentrations of O-ethyl S-(2

  9. Mycotic aneurysms in intravenous drug abusers: the utility of intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Shetty, P.C.; Krasicky, G.A.; Sharma, R.P.; Vemuri, B.R.; Burke, M.M.

    1985-01-01

    Two-hundred thirteen intravenous digital subtraction angiographic (DSA) examinations were performed on 195 intravenous drug abusers to rule out the possibility of a mycotic aneurysm in a groin, neck, or upper extremity infection. Twenty-three surgically proved cases of mycotic aneurysm were correctly identified with no false positive results. In addition, six cases of major venous occlusion were documented. The authors present the results of their experience and conclude that DSA is an effective and cost-efficient method of examining this high risk patient population

  10. Tale of two sites: capillary versus arterial blood glucose testing in the operating room.

    Science.gov (United States)

    Akinbami, Felix; Segal, Scott; Schnipper, Jeffrey L; Stopfkuchen-Evans, Matthias; Mills, Jonathan; Rogers, Selwyn O

    2012-04-01

    Pre- and intraoperative glycemic control has been identified as a putative target to improve outcomes of surgical patients. Glycemic control requires frequent monitoring of blood glucose levels with appropriate adjustments. However, monitoring standards have been called into question, especially in cases in which capillary samples are used. Point-of-care testing (POCT) using capillary samples and glucometers has been noted to give relatively accurate results for critically ill patients. However, the package inserts of most glucometers warn that they should not be used for patients in shock. This has led clinicians to doubt their accuracy in the operating room. The accuracy of capillary samples when tested in patients undergoing surgical procedures has not been proven. This study aims to determine the accuracy of intraoperative blood glucose values using capillary samples relative to arterial samples. A prospective study was conducted by collecting paired capillary and arterial samples of patients undergoing major operations at a tertiary medical center from August 2009 to May 2011. Subjects were a convenience sample of patients who had arterial lines and needed glucose testing while undergoing the procedure. Precision Xceed Pro (Abbott) handheld glucometers were used to obtain the blood glucose values. Our primary outcome of interest was the degree of correlation between capillary and arterial blood glucose values or the degree to which arterial glucose levels can be predicted by capillary glucose samples. We used linear regression and the Student t tests for statistical analyses. Seventy-two-paired samples were collected. Of the cases, 54% were major abdominal operations, whereas 24% were vascular operations. The mean values ± standard deviation for glucose levels were 146 ± 35 mg/dL (capillary) and 147 ± 36 mg/dL (arterial). The mean time ± standard deviation between the collection of both samples was 3.5 ± 1.3 minutes. The regression coefficient showed a

  11. Orthostatic stability with intravenous levodopa

    Directory of Open Access Journals (Sweden)

    Shan H. Siddiqi

    2015-08-01

    Full Text Available Intravenous levodopa has been used in a multitude of research studies due to its more predictable pharmacokinetics compared to the oral form, which is used frequently as a treatment for Parkinson’s disease (PD. Levodopa is the precursor for dopamine, and intravenous dopamine would strongly affect vascular tone, but peripheral decarboxylase inhibitors are intended to block such effects. Pulse and blood pressure, with orthostatic changes, were recorded before and after intravenous levodopa or placebo—after oral carbidopa—in 13 adults with a chronic tic disorder and 16 tic-free adult control subjects. Levodopa caused no statistically or clinically significant changes in blood pressure or pulse. These data add to previous data that support the safety of i.v. levodopa when given with adequate peripheral inhibition of DOPA decarboxylase.

  12. Acute effects of the glucagon-like peptide-1 receptor agonist, exenatide, on blood pressure and heart rate responses to intraduodenal glucose infusion in type 2 diabetes.

    Science.gov (United States)

    Thazhath, Sony S; Marathe, Chinmay S; Wu, Tongzhi; Chang, Jessica; Khoo, Joan; Kuo, Paul; Checklin, Helen L; Bound, Michelle J; Rigda, Rachael S; Horowitz, Michael; Jones, Karen L; Rayner, Christopher K

    2017-01-01

    To evaluate the effects of the glucagon-like peptide-1 receptor agonist, exenatide, on blood pressure and heart rate during an intraduodenal glucose infusion in type 2 diabetes. Nine subjects with type 2 diabetes were randomised to receive intravenous exenatide or saline control in a crossover design. Glucose (3 kcal min -1 ) was infused via an intraduodenal manometry catheter for 60 min. Blood pressure, heart rate, and the frequency and amplitude of duodenal pressure waves were measured at regular intervals. Gastrointestinal symptoms were monitored using 100 mm visual analogue scales. During intraduodenal glucose infusion (0-60 min), diastolic (p (0-60)  = 0.03) and mean arterial (p (0-60)  = 0.03) blood pressures and heart rate (p (0-60)  = 0.06; p (0-120)  = 0.03)) were higher with exenatide compared to placebo. The increase in the area under the curve for diastolic blood pressure and mean arterial blood pressure was related directly to the suppression of the duodenal motility index with exenatide compared to control (p = 0.007 and 0.04, respectively). In type 2 diabetes, intravenous exenatide increases mean arterial blood pressure and heart rate during an intraduodenal glucose infusion, supporting the need for further research with exenatide for its potential use in postprandial hypotension. © The Author(s) 2016.

  13. GLP-1-(9-36) amide reduces blood glucose in anesthetized pigs by a mechanism that does not involve insulin secretion

    DEFF Research Database (Denmark)

    Deacon, Carolyn F; Plamboeck, Astrid; Møller, Søren

    2002-01-01

    impossible to assess its true efficacy in vivo. In chloralose-anesthetized pigs given valine-pyrrolidide (to block endogenous DPP IV activity), the independent effects of GLP-1-(7-36) amide on glucose and insulin responses to intravenous glucose were assessed, and the metabolite generated by DPP IV, GLP-1......-(9-36) amide, was investigated for any ability to influence these responses. GLP-1-(7-36) amide enhanced insulin secretion (P amide was without effect, either alone or when coinfused with GLP-1-(7-36) amide. In contrast, GLP-1-(9-36) amide did affect glucose responses (P...... amide (73 +/- 19 mmol x l(-1) x min; P amide (62 +/- 13 mmol x l(-1) x min; P amide + GLP-1-(9-36) amide (50 +/-13 mmol x l(-1) x min; P

  14. Comparison of postinfusion phlebitis in intravenous push versus intravenous piggyback cefazolin.

    Science.gov (United States)

    Biggar, Constance; Nichols, Cynthia

    2012-01-01

    Reducing health care costs without adversely affecting patient safety is a constant challenge for health care institutions. Cefazolin prophylaxis via intravenous push (IVP) is more cost-effective than via intravenous piggyback (IVPB). The purpose of this study was to determine whether patient safety would be compromised (ie, an increased rate of phlebitis) with a change to the IVP method. Rates of phlebitis in orthopedic surgical patients receiving cefazolin prophylaxis via IVP versus IVPB were evaluated in a prospective quasi-experimental design of 240 patients. The first 120 subjects received cefazolin via IVPB, and the second 120 subjects received it via IVP. Results indicated no statistically significant difference in phlebitis rates in the IVPB (3.4%) versus the IVP groups (3.3%).

  15. In women with PCOS, waist circumference is a better surrogate of glucose and lipid metabolism than disease status per se.

    Science.gov (United States)

    Pazderska, Agnieszka; Kyaw Tun, Tommy; Phelan, Niamh; McGowan, Anne; Sherlock, Mark; Behan, LucyAnn; Boran, Gerard; Gibney, James

    2018-04-01

    Cardiometabolic abnormalities are recognized in polycystic ovary syndrome (PCOS). However, over-emphasis on PCOS as a risk factor potentially results in over-investigation and treatment of some women with and under-recognition of cardiometabolic risk in obese women without PCOS. Our objective was to explore the association between waist circumference (WC) and indices of glucose and lipid metabolism in women with and without PCOS. (i) An exploratory cross-sectional study investigating association of potential cardiometabolic risk markers (PCOS status, anthropometric measures, hsCRP, HOMA-IR, SHBG, testosterone) with indices of glucose (frequently sampled intravenous glucose tolerance test) and lipid metabolism (postprandial studies and lipoprotein particle size) in 61 women with (n = 29) and without (n = 32) PCOS; (ii) a cross-sectional study in 103 PCOS women and 102 BMI-matched controls to explore if between-group differences in indices of lipid and glucose metabolism persist after adjusting for WC. NIH criteria were used for PCOS diagnosis. Study 1: Univariate correlations and stepwise regression modelling identified waist circumference (WC), as a better surrogate than PCOS status, independently predicting multiple variables of glucose and lipid metabolism. Study 2: Fasting insulin and triglyceride, hsCRP and insulin resistance (according to HOMA-IR and SiM [Avignon index]) were greater, while fasting HDL was lower in women with PCOS compared to BMI-matched women without PCOS. None of these differences persisted when a subset of 80 women with PCOS was compared with 80 women without PCOS, pair-matched for WC. Some cardiometabolic abnormalities in PCOS are related to central obesity, and following adjustment for WC does not differ from normal subjects. Waist circumference measurement has potential to take precedence over PCOS status as part of the assessment of cardiometabolic risk in reproductive-age women. © 2017 John Wiley & Sons Ltd.

  16. Development of 18F-FDG ([F-18]-2-fluoro-2-deoxy-D-glucose) injection for imaging of tumor reflecting glucose metabolism. Results of preclinical studies

    International Nuclear Information System (INIS)

    Ino, Sento; Shimada, Takayuki; Kanagawa, Masaru; Suzuki, Noriaki; Kondo, Susumu; Shirakami, Yoshifumi; Ito, Osamu; Kato-Azuma, Makoto

    1999-01-01

    Fluorine-18-2-fluoro-2-deoxy-D-glucose ( 18 F-FDG) injection was prepared by a modification of a method originally developed by Hamacher et al. The dosage form is the injectable solution (2 ml) containing 185 MBq of 18 F-FDG at a calibration time. Preclinical studies of the agent were performed. Its radiochemical purity is more than 95% and expiration time is 4 hours after the calibration time at ambient temperature. No toxicity was observed with up to 200 mg/kg and 100 mg/kg of non-radioactive FDG intravenously injected to rats and dogs in single dose toxicity tests, respectively. Biodistribution studies demonstrated that the radioactivity was mainly distributed into brain (3.0 to 3.3% I.D./Organ at 30 minutes) and heart (4.2 to 5.8% I.D./Organ at 1 to 3 hours) after intravenous injection of the agent to normal rats. In a tumor transplanted mouse model (colon 26), tumor uptake was 10.9±3.5% I.D./g at 1 hr after intravenous injection of the agent, the radioactivity was retained until 3 hours. The radiation absorbed dose was estimated according to the MIRD Pamphlet based on the biodistribution data both in humans reported by Mejia et al. and rats described in this report. The radiation absorbed dose was not higher than those of commercially available radiopharmaceuticals. In conclusion, the 18 F-FDG injection is expected to be useful for further clinical application. (author)

  17. [Peripheral intravenous catheter-related phlebitis].

    Science.gov (United States)

    van der Sar-van der Brugge, Simone; Posthuma, E F M Ward

    2011-01-01

    Phlebitis is a very common complication of the use of intravenous catheters. Two patients with an i.v. catheter complicated by thrombophlebitis are described. Patient A was immunocompromised due to chronic lymphatic leukaemia and developed septic thrombophlebitis with positive blood cultures for S. Aureus. Patient B was being treated with flucloxacillin because of an S. Aureus infection and developed chemical phlebitis. Septic phlebitis is rare, but potentially serious. Chemical or mechanical types of thrombophlebitis are usually less severe, but happen very frequently. Risk factors include: female sex, previous episode of phlebitis, insertion at (ventral) forearm, emergency placement and administration of antibiotics. Until recently, routine replacement of peripheral intravenous catheters after 72-96 h was recommended, but randomised controlled trials have not shown any benefit of this routine. A recent Cochrane Review recommends replacement of peripheral intravenous catheters when clinically indicated only.

  18. Osmotic load from glucose polymers.

    Science.gov (United States)

    Koo, W W; Poh, D; Leong, M; Tam, Y K; Succop, P; Checkland, E G

    1991-01-01

    Glucose polymer is a carbohydrate source with variable chain lengths of glucose units which may result in variable osmolality. The osmolality of two commercial glucose polymers was measured in reconstituted powder infant formulas, and the change in osmolality of infant milk formulas at the same increases in energy density (67 kcal/dL to 81 and 97 kcal/dL) from the use of additional milk powder or glucose polymers was compared. All samples were prepared from powders (to nearest 0.1 mg), and osmolality was measured by freezing point depression. For both glucose polymers the within-batch variability of the measured osmolality was less than 3.5%, and between-batch variability of the measured osmolality was less than 9.6%. The measured osmolality varies linearly with energy density (p less than 0.001) and was highest in infant formula reconstituted from milk powder alone. However, there exist significant differences in the measured osmolality between different glucose polymer preparations. At high energy densities (greater than or equal to 97 kcal/dL), infant milk formulas prepared with milk powder alone or with the addition of certain glucose polymer preparation may have high osmolality (greater than or equal to 450 mosm/kg) and theoretically predispose the infant to complications of hyperosmotic feeds.

  19. Protein Adsorption to In-Line Filters of Intravenous Administration Sets.

    Science.gov (United States)

    Besheer, Ahmed

    2017-10-01

    Ensuring compatibility of administered therapeutic proteins with intravenous administration sets is an important regulatory requirement. A low-dose recovery during administration of low protein concentrations is among the commonly observed incompatibilities, and it is mainly due to adsorption to in-line filters. To better understand this phenomenon, we studied the adsorption of 4 different therapeutic proteins (2 IgG1s, 1 IgG4, and 1 Fc fusion protein) diluted to 0.01 mg/mL in 5% glucose (B. Braun EcoFlac; B. Braun Melsungen AG, Melsungen, Germany) or 0.9% sodium chloride (NaCl; Freeflex; Fresenius Kabi, Friedberg, Germany) solutions to 8 in-line filters (5 positively charged and 3 neutral filters made of different polymers and by different suppliers). The results show certain patterns of protein adsorption, which depend to a large extent on the dilution solution and filter material, and to a much lower extent on the proteins' biophysical properties. Investigation of the filter membranes' zeta potential showed a correlation between the observed adsorption pattern in 5% glucose solution and the filter's surface charge, with higher protein adsorption for the strongly negatively charged membranes. In 0.9% NaCl solution, the surface charges are masked, leading to different adsorption patterns. These results contribute to the general understanding of the protein adsorption to IV infusion filters and allow the design of more efficient compatibility studies. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  20. Disposition of nasal, intravenous, and oral methadone in healthy volunteers.

    Science.gov (United States)

    Dale, Ola; Hoffer, Christine; Sheffels, Pamela; Kharasch, Evan D

    2002-11-01

    Nasal administration of many opioids demonstrates rapid uptake and fast onset of action. Nasal administration may be an alternative to intravenous and oral administration of methadone and was therefore studied in human volunteers. The study was approved by the Institutional Review Board of the University of Washington, Seattle. Eight healthy volunteers (6 men and 2 women) aged 19 to 33 years were enrolled after informed written consent was obtained. Subjects received 10 mg methadone hydrochloride nasally, orally, or intravenously on 3 separate occasions in a crossover design. Nasal methadone (50 mg/mL in aqueous solution) was given as a 100-microL spray in each nostril (Pfeiffer BiDose sprayer). Blood samples for liquid chromatography-mass spectrometry analyses of methadone and the metabolite 2-ethyl-1,5-dimethyl-3,3-diphenylpyrrolinium were drawn for up to 96 hours. The methadone effect was measured by noninvasive infrared pupilometry coincident with blood sampling. Nasal uptake of methadone was rapid, with maximum plasma concentrations occurring within 7 minutes. The maximum effects of intravenous, nasal, and oral methadone, on the basis of dark-adapted pupil diameter, were reached in about 15 minutes, 30 minutes, and 2 hours, respectively. The respective durations were 24, 10, and 8 hours. Both nasal and oral bioavailabilities were 0.85. Subjects reported that nasal methadone caused a burning sensation. Nasal administration of methadone results in rapid absorption and onset of effect and high bioavailability, which was greater than that reported for other nasal opioids, with a similar duration of effect. Nasal administration may be an alternative route of methadone administration; however, improved formulations are desirable to reduce nasal irritation.

  1. Optimizing the use of intravenous therapy in internal medicine.

    Science.gov (United States)

    Champion, Karine; Mouly, Stéphane; Lloret-Linares, Celia; Lopes, Amanda; Vicaut, Eric; Bergmann, Jean-François

    2013-10-01

    We aimed to evaluate the impact of physicians' educational programs in the reduction of inappropriate intravenous lines in internal medicine. Fifty-six French internal medicine units were enrolled in a nationwide, prospective, blinded, randomized controlled trial. Forms describing the patients with an intravenous line and internal medicine department characteristics were filled out on 2 separate days in January and April 2007. Following the first visit, all units were randomly assigned to either a specific education program on the appropriate indications of an intravenous line, during February and March 2007, or no training (control group). The Investigators' Committee then blindly evaluated the clinical relevance of the intravenous line according to pre-established criteria. The primary outcome was the percentage of inappropriate intravenous lines. During January 2007, intravenous lines were used in 475 (24.9%) of the 1910 hospitalized patients. Of these, 80 (16.8%) were considered inappropriate. In April 2007, 416 (22.8%) of the 1823 hospitalized patients received an intravenous line, which was considered in 10.2% (21/205) of patients managed by trained physicians, versus 16.6% (35/211) of patients in the control group (relative difference 39%; 95% confidence interval, -0.6-13.3; P = .05). Reduced intravenous administration of fluids, antibiotics, and analgesics accounted for the observed decrease. The use of a simple education program reduced the rate of inappropriate intravenous lines by almost 40% in an internal medicine setting (NCT01633307). Copyright © 2013 Elsevier Inc. All rights reserved.

  2. A widespread amino acid polymorphism at codon 905 of the glycogen-associated regulatory subunit of protein phosphatase-1 is associated with insulin resistance and hypersecretion of insulin

    DEFF Research Database (Denmark)

    Hansen, Lars; Hansen, Torben; Vestergaard, Henrik

    1995-01-01

    with indirect calorimetry in order to elucidate the potential impact of the Tyr905 substitution on the whole body glucose metabolism. Interestingly, the Tyr905 variant was associated with altered routing of glucose: a decreased insulin stimulated non-oxidative glucose metabolism of peripheral tissues (glycogen...... synthesis) (p population-based sample of 380 unrelated young healthy Caucasians was examined during a combined intravenous glucose and tolbutamide test to address whether the Asp905/Tyr905 polymorphism...

  3. Vitamin C: intravenous use by complementary and alternative medicine practitioners and adverse effects.

    Directory of Open Access Journals (Sweden)

    Sebastian J Padayatty

    2010-07-01

    Full Text Available Anecdotal information and case reports suggest that intravenously administered vitamin C is used by Complementary and Alternate Medicine (CAM practitioners. The scale of such use in the U.S. and associated side effects are unknown.We surveyed attendees at annual CAM Conferences in 2006 and 2008, and determined sales of intravenous vitamin C by major U.S. manufacturers/distributors. We also queried practitioners for side effects, compiled published cases, and analyzed FDA's Adverse Events Database. Of 199 survey respondents (out of 550, 172 practitioners administered IV vitamin C to 11,233 patients in 2006 and 8876 patients in 2008. Average dose was 28 grams every 4 days, with 22 total treatments per patient. Estimated yearly doses used (as 25 g/50 ml vials were 318,539 in 2006 and 354,647 in 2008. Manufacturers' yearly sales were 750,000 and 855,000 vials, respectively. Common reasons for treatment included infection, cancer, and fatigue. Of 9,328 patients for whom data is available, 101 had side effects, mostly minor, including lethargy/fatigue in 59 patients, change in mental status in 21 patients and vein irritation/phlebitis in 6 patients. Publications documented serious adverse events, including 2 deaths in patients known to be at risk for IV vitamin C. Due to confounding causes, the FDA Adverse Events Database was uninformative. Total numbers of patients treated in the US with high dose vitamin C cannot be accurately estimated from this study.High dose IV vitamin C is in unexpectedly wide use by CAM practitioners. Other than the known complications of IV vitamin C in those with renal impairment or glucose 6 phosphate dehydrogenase deficiency, high dose intravenous vitamin C appears to be remarkably safe. Physicians should inquire about IV vitamin C use in patients with cancer, chronic, untreatable, or intractable conditions and be observant of unexpected harm, drug interactions, or benefit.

  4. Complex intravenous anesthesia in interventional procedures

    International Nuclear Information System (INIS)

    Xie Zonggui; Hu Yuanming; Huang Yunlong; You Yong; Wu Juan; Huang Zengping; Li Jian

    2006-01-01

    Objective: To evaluate the value and safety of Diprivan and Fentany intravenous administration of analgesia in interventional procedures. Methods: Diprivan with Fentany intravenous administration for analgesia was used in eighty interventional procedures of sixty-five patients, without tracheal tube insertion. Vital signs including HR, BP, arterial oxygen saturation (SpO 2 ) and patients' reaction to operating were recorded. Results: Intravenous anesthesia was cared out successfully in eighty interventional procedures, with patients under sleeping condition during the operation, together with no pain and no agony memory of the procedure. The amount of Diprivan was 500±100 mg and Fentany was 0.2±0.025 mg. Mean arterial pressure and SpO 2 were 11.4±2.2 kPa, 10.6±2.1 kPa and 98±1.0, 96±1.5 respectively before and after ten minutes of the operation, with no significant difference. Conclusions: Diprivan with Fentany intravenous administration for interventional procedure analgesia possess good safety, painless and no agony memory of the procedure; therefor ought to be recommended. (authors)

  5. Effects of dietary glucose and sodium chloride on intestinal glucose absorption of common carp (Cyprinus carpio L.).

    Science.gov (United States)

    Qin, Chaobin; Yang, Liping; Zheng, Wenjia; Yan, Xiao; Lu, Ronghua; Xie, Dizhi; Nie, Guoxing

    2018-01-08

    The co-transport of sodium and glucose is the first step for intestinal glucose absorption. Dietary glucose and sodium chloride (NaCl) may facilitate this physiological process in common carp (Cyprinus carpio L.). To test this hypothesis, we first investigated the feeding rhythm of intestinal glucose absorption. Carps were fed to satiety once a day (09:00 a.m.) for 1 month. Intestinal samples were collected at 01:00, 05:00, 09:00, 13:00, 17:00 and 21:00. Result showed that food intake greatly enhanced sodium/glucose cotransporter 1 (SGLT1) and glucose transporter type 2 (GLUT2) expressions, and improved glucose absorption, with highest levels at 09:00 a.m.. Then we designed iso-nitrogenous and iso-energetic diets with graded levels of glucose (10%, 20%, 30%, 40% and 50%) and NaCl (0%, 1%, 3% and 5%), and submitted to feeding trial for 10 weeks. The expressions of SGLT1 and GLUT2, brush border membrane vesicles (BBMVs) glucose transport and intestinal villus height were determined after the feeding trial. Increasing levels of dietary glucose and NaCl up-regulated mRNA and protein levels of SGLT1 and GLUT2, enhanced BBMVs glucose transport in the proximal, mid and distal intestine. As for histological adaptive response, however, high-glucose diet prolonged while high-NaCl diet shrank intestinal villus height. Furthermore, we also found that higher mRNA levels of SGLT1 and GLUT2, higher glucose transport capacity of BBMVs, and higher intestinal villus were detected in the proximal and mid intestine, compared to the distal part. Taken together, our study indicated that intestinal glucose absorption in carp was primarily occurred in the proximal and mid intestine, and increasing levels of dietary glucose and NaCl enhanced intestinal glucose absorption in carp. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Protein structural development of threadfin bream ( Nemipterus spp.) surimi gels induced by glucose oxidase.

    Science.gov (United States)

    Wang, Lei; Fan, Daming; Fu, Lulu; Jiao, Xidong; Huang, Jianlian; Zhao, Jianxin; Yan, Bowen; Zhou, Wenguo; Zhang, Wenhai; Ye, Weijian; Zhang, Hao

    2018-01-01

    This study investigated the effect of glucose oxidase on the gel properties of threadfin bream surimi. The gel strength of surimi increased with the addition of 0.5‰ glucose oxidase after two-step heating. Based on the results of the chemical interactions, the hydrophobic interaction and disulfide bond of glucose oxidase-treated surimi samples increased compared with the control samples at the gelation temperature and gel modori temperature. The surface hydrophobicity of samples with glucose oxidase and glucose increased significantly ( p glucose oxidase induced more α-helixes to turn into a more elongated random and flocculent structure. Glucose oxidase changes the secondary structure of the surimi protein, making more proteins depolarize and stretch and causing actomyosin to accumulate to each other, resulting in the formation of surimi gel.

  7. Development of {sup 18}F-FDG ([F-18]-2-fluoro-2-deoxy-D-glucose) injection for imaging of tumor reflecting glucose metabolism. Results of preclinical studies

    Energy Technology Data Exchange (ETDEWEB)

    Ino, Sento; Shimada, Takayuki; Kanagawa, Masaru; Suzuki, Noriaki; Kondo, Susumu; Shirakami, Yoshifumi; Ito, Osamu; Kato-Azuma, Makoto [Nihon Medi-Physics Co., Ltd., Sodegaura, Chiba (Japan). Research Center

    1999-07-01

    Fluorine-18-2-fluoro-2-deoxy-D-glucose ({sup 18}F-FDG) injection was prepared by a modification of a method originally developed by Hamacher et al. The dosage form is the injectable solution (2 ml) containing 185 MBq of {sup 18}F-FDG at a calibration time. Preclinical studies of the agent were performed. Its radiochemical purity is more than 95% and expiration time is 4 hours after the calibration time at ambient temperature. No toxicity was observed with up to 200 mg/kg and 100 mg/kg of non-radioactive FDG intravenously injected to rats and dogs in single dose toxicity tests, respectively. Biodistribution studies demonstrated that the radioactivity was mainly distributed into brain (3.0 to 3.3% I.D./Organ at 30 minutes) and heart (4.2 to 5.8% I.D./Organ at 1 to 3 hours) after intravenous injection of the agent to normal rats. In a tumor transplanted mouse model (colon 26), tumor uptake was 10.9{+-}3.5% I.D./g at 1 hr after intravenous injection of the agent, the radioactivity was retained until 3 hours. The radiation absorbed dose was estimated according to the MIRD Pamphlet based on the biodistribution data both in humans reported by Mejia et al. and rats described in this report. The radiation absorbed dose was not higher than those of commercially available radiopharmaceuticals. In conclusion, the {sup 18}F-FDG injection is expected to be useful for further clinical application. (author)

  8. Association Between Exercise and Blood Glucose Levels In Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Eryna Laili Putri

    2017-02-01

    Full Text Available Diabetes Mellitus (DM is a chronic disease with high prevalence, associated with various debilitating complications and can decreases the quality of life in people with it. It is important for people with DM to doing exercise to control the stability of their blood glucose levels. The purpose of this study was to finding out the association between frequency, duration, and intensity of exercise with average blood glucose levels in people with DM. This was an observational study that used case control design. Data obtained from interview with 20 samples from case group and 20 samples from control group, that had been chosen with systematic random sampling technique. Dependent variable of this study was the average blood glucose levels and independents variables were frequency, duration, intensity, and the kind of exercise. This study used Chi Square test 3 × 2 contingency tables to finding out the association and risk of dependent variable with independent variables,. The results showed that exercise factors that associated to average blood glucose levels were duration of exercise (p = 0.022 and intensity of exercise (p = 0.021. The frequency of exercise does not associated to average blood glucose levels (p = 0.340. Diabetic patients who did not do any exercise have the risk of having uncontrolled blood glucose levels. The conclusion was duration and intensity of exercise related significantly to blood glucose levels. By doing exercise three times a week for 30 minutes or more can decreases the risk of uncontrolled blood glucose levels in people with DM. Keywords: Diabetes mellitus, exercise, average blood glucose levels

  9. Spatial relationship between tumor perfusion and endogeneous glucose distribution

    International Nuclear Information System (INIS)

    Schroeder, T.; Larrier, N.; Viglianti, B.; Rabbani, Z.N.; Peltz, C.; Vujascovic, Z.; Dewhirst, M.W.

    2003-01-01

    Earlier studies detecting glucose in tissue and solid tumors by bioluminescence imaging suggested, that glucose distribution patterns may be spatially related to functional vascularity. The purpose of this study was to evaluate this relationship by comparing glucose distribution patterns as determined by bioluminescence imaging to perfusion patterns of endogeneous Hoechst 33342 in rats bearing mammary carcinomas. R 3230 mammary carcinoma cells have been implanted subcutaneously into 7 female Fischer 344 rats. Two months post implantation, after injection of Hoechst 33342 the tumors were removed and snap frozen to conserve metabolite levels. Concomitantly, blood was sampled from the animals for analysis of glucose concentrations using a micodialysis analyzer. Cryosections of the tumors have been prepared, and every slice has been analyzed for both, Hoechst binding by fluorescence microscopy, and for glucose distribution patterns using bioluminescence imaging. In many cases vascular structures could be retrieved by the spatial pattern of glucose distribution. In some cases however, higher glucose concentrations could be found independent from Hoechst signal. On the other hand, regions of high Hoechst signal are not necessarily correlated with high glucose concentrations. When comparing blood and tissue glucose levels, tissue glucose content as measured with bioluminescence imaging (1.9-3.5 mM) is considerably lower than blood glucose (5.6-8.0 mM), demonstrating the expected gradient from blood to tissue. This study demonstrates the feasibility of monitoring glucose gradients in relation to functional vasculature throughout the body, from blood down to tissue or tumor and further, throughout the microenvironment of the solid tumor. Glucose distribution patterns may be an important tool in perfusion studies, e. g. in detecting the direction of blood flow in ex-vivo samples or in estimating glucose consumption rates of tumor cells adjacent to or in between perfused

  10. Glucose in vaginal secretions before and after oral glucose tolerance testing in women with and without recurrent vulvovaginal candidiasis.

    Science.gov (United States)

    Ehrström, Sophia; Yu, Anna; Rylander, Eva

    2006-12-01

    To measure the change of glucose in vaginal secretions during glucose tolerance testing in women with recurrent vulvovaginal candidiasis and in healthy control subjects. Thirty-eight women with recurrent vulvovaginal candidiasis and 45 healthy, age-matched controls completed a health questionnaire regarding general and gynecologic health and food and alcohol habits. They all underwent an oral glucose tolerance test and a vaginal examination. Vaginal secretion was collected from the proximal part of the vagina. Glucose in plasma and in vaginal secretions were measured at fasting and after 2 hours and analyzed with the hexokinase method. A sample size analysis showed that the number of subjects included in the study was sufficient for a beta value of 0.80, at the significance level of alpha=.05, at a difference in glucose in vaginal secretions of 30% after oral glucose tolerance test. In healthy women, the median level of glucose in vaginal secretions was 5.2 mM before and 3.7 mM after oral glucose tolerance test, and plasma glucose was 5.0 mM before and 5.8 mM after oral glucose tolerance test. No significant difference was seen regarding change of glucose level in vaginal secretions and plasma glucose after testing, compared with before oral glucose tolerance testing. There were no differences between women with recurrent vulvovaginal candidiasis and control subjects regarding change in glucose level in vaginal secretions or in plasma during oral glucose tolerance test. II-2.

  11. Evaluation of glucose and insulin response to haylage diets with different content of nonstructural carbohydrates in 2 breeds of horses.

    Science.gov (United States)

    Lindåse, S; Müller, C; Nostell, K; Bröjer, J

    2018-04-09

    Information about the effect of nonstructural carbohydrates (NSCs) in forage on the postprandial glucose and insulin response in horses is scarce. This is of interest as postprandial hyperinsulinemia in horses is a risk factor for laminitis. In addition, insulin sensitivity (IS) differs between breeds. The aim was to evaluate the postprandial glucose and insulin response to haylage diets with different NSC content in horses of 2 different breeds and to evaluate the relationship between the postprandial insulin response and measures of IS derived from a frequently sampled intravenous glucose tolerance test (FSIGTT). Standardbreds (n = 9) and Icelandic horses (n = 9) with a mean body condition score of 5.5 ± 0.6 (scale 1-9) were studied. Horses were clinically healthy at the start of the study and had no history of endocrinopathic laminitis. The experiment was conducted as a replicate 3 × 3 Latin square, in which horses were fed haylage diets with low (4.2%), medium (13.6%), and high (18.2%) NSC content of dry matter. Blood sampling was performed before feeding and every 30 min until 300 min after feeding. An FSIGTT was also performed in all horses. The early (first 60 min) and the total (300 min) postprandial glucose and insulin response (area under the curve [AUC]) was higher after a meal of both medium and high NSC haylage in comparison with low NSC haylage when both breeds were combined (P ≤ 0.02). There was a main effect of breed for the early (P ≤ 0.004) but not for the total (P > 0.12) postprandial glucose and insulin response. The IS index was comparable between breeds (P = 0.75). The natural logarithm of the peak concentration, the AUC for the first 60 min and the total AUC for insulin, after a meal of medium and high NSC haylage, were moderately negatively correlated (P haylage with low NSC content (P > 0.054). This study demonstrates that the postprandial insulin response is affected by both the NSC content of haylage and the horse's IS. However

  12. Improvement in glucose biosensing response of electrochemically grown polypyrrole nanotubes by incorporating crosslinked glucose oxidase.

    Science.gov (United States)

    Palod, Pragya Agar; Singh, Vipul

    2015-10-01

    In this paper a novel enzymatic glucose biosensor has been reported in which platinum coated alumina membranes (Anodisc™s) have been employed as templates for the growth of polypyrrole (PPy) nanotube arrays using electrochemical polymerization. The PPy nanotube arrays were grown on Anodisc™s of pore diameter 100 nm using potentiostatic electropolymerization. In order to optimize the polymerization time, immobilization of glucose oxidase (GOx) was first performed using physical adsorption followed by measuring its biosensing response which was examined amperometrically for increasing concentrations of glucose. In order to further improve the sensing performance of the biosensor fabricated for optimum polymerization duration, enzyme immobilization was carried out using cross-linking with glutaraldehyde and bovine serum albumin (BSA). Approximately six fold enhancement in the sensitivity was observed in the fabricated electrodes. The biosensors also showed a wide range of linear operation (0.2-13 mM), limit of detection of 50 μM glucose concentration, excellent selectivity for glucose, notable reliability for real sample detection and substantially improved shelf life. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Noninvasive glucose monitoring using saliva nano-biosensor

    Directory of Open Access Journals (Sweden)

    Wenjun Zhang

    2015-06-01

    Full Text Available Millions of people worldwide live with diabetes and several millions die from it each year. A noninvasive, painless method of glucose testing would highly improve compliance and glucose control while reducing complications and overall disease management costs. To provide accurate, low cost, and continuous glucose monitoring, we have developed a unique, disposable saliva nano-biosensor. More than eight clinical trials on real-time noninvasive salivary glucose monitoring were carried out on two healthy individuals (a 2–3 h-period for each trial, including both regular food and standard glucose beverage intake with more than 35 saliva samples obtained. Excellent clinical accuracy was revealed as compared to the UV Spectrophotometer. By measuring subjects’ salivary glucose and blood glucose in parallel, we found the two generated profiles share the same fluctuation trend but the correlation between them is individual dependent. There is a time lag between the peak glucose values from blood and from saliva. However, the correlation between the two glucose values at fasting is constant for each person enabling noninvasive diagnosis of diabetes through saliva instead of blood. Furthermore, a good correlation of glucose levels in saliva and in blood before and 2 h after glucose intake was observed. Glucose monitoring before and 2 h after meals is usually prescribed by doctors for diabetic patients. Thus, this disposable biosensor will be an alternative for real-time salivary glucose tracking at any time.

  14. The influence of blood glucose level on distribution of 18F-FDG in mice with tumor

    International Nuclear Information System (INIS)

    Fu Zhanli; Lin Jinghui; Wang Rongfu; Zhu Shaoli; Zhang Chunli; Pan Zhongyun

    2003-01-01

    To explore the influence of blood glucose level on 18 F-FDG uptake in tumor and normal tissues of mice, thirty five mice carrying Ehrlich ascitic cancer (EAC) are fasted 20 h and divided into four groups. The glucose loading group (n=12) and the control group (n=11) is given a solution of 50% glucose and distilled water orally just one hour before the 18 F FDG injection. Another two groups (n=5, n=7) is given a solution of 10%, 30% glucose respectively. Before 18 F-FDG intravenous injection, blood glucose levels are measured. The mice are killed one hour after the 18 F FDG injection. The tumor and normal tissues are excised, weighed, and counted by a γ well counter. The quantity of 18 F-FDG uptake is expressed as standardized uptake value (SUV). Blood glucose levels of the mice with EAC in the glucose loading group are significantly elevated than the control group (11.98 ± 3.01 mmol/L vs. 3.95 ± 1. 11 mmol/L, P 18 F-FDG uptake ratios of tumor and muscle in the glucose-loading group (1.34, 0.86, 0.48, 0.09, 1.38 respectively) are significantly lower than those in the control group (3.02, 2.62, 0.80, 0.16, 5.38 respectively) (P 18 F-FDG uptake ratios of tumor and brain, heart and blood in the glucose loading group (8.31. 1.05, 1.58, 103.00 respectively) are significantly higher than those in the control group (1.57, 0.64, 1.20, 9.73 respectively) (P 18 F-FDG distribution in mice. suggesting the blood glucose level should be controlled during clinically 18 F-FDG imaging

  15. Effects of medetomidine on serum glucose in cattle calves.

    Science.gov (United States)

    Tariq, Muhammad; Kalhoro, Amir Bukhsh; Sarwar, Mian Saeed; Khan, Hamayun; Ahmad, Shakoor; Hassan, Sayed Mubashir; Zahoor, Arshad

    2016-05-01

    An experimental study was carried out to compare physiological effects (serum glucose level) of medetomidine in Red Sindhi cattle calves at three different doses i.e. 8, 10 and 12µg/kg body weight intravenously. Medetomidine produced a dose dependent significant (P<0.01) increase in serum glucose level with a maximum increase observed at 30 minutes with 8µg/kg, 10μg/kg and 12μg/kg body weight respectively. Start of sedation, degree of sedation and total duration of sedation were all dose dependent and the values obtained were significantly (P<0.01) different from each other. It was observed that the sedation was rapid, deep and longer with the higher doses of medetomidine i.e. 12μg/kg. The results of the present study shows that medetomidine is a very effective and safest drug use as sedative for calves which in lower doses (8μg/kg) can be used as a pre-anesthetic and for restraining of the animal, while higher calculated doses (10μg/kg, 12μg/kg) can be used to execute the minor surgical procedures.

  16. Pleocytosis is not fully responsible for low CSF glucose in meningitis.

    Science.gov (United States)

    Baud, Maxime O; Vitt, Jeffrey R; Robbins, Nathaniel M; Wabl, Rafael; Wilson, Michael R; Chow, Felicia C; Gelfand, Jeffrey M; Josephson, S Andrew; Miller, Steve

    2018-01-01

    The mechanism of hypoglycorrhachia-low CSF glucose-in meningitis remains unknown. We sought to evaluate the relative contribution of CSF inflammation vs microorganisms (bacteria and fungi) in lowering CSF glucose levels. We retrospectively categorized CSF profiles into microbial and aseptic meningitis and analyzed CSF leukocyte count, glucose, and protein concentrations. We assessed the relationship between these markers using multivariate and stratified linear regression analysis for initial and repeated CSF sampling. We also calculated the receiver operating characteristics of CSF glucose and CSF-to-serum glucose ratios to presumptively diagnose microbial meningitis. We found that increasing levels of CSF inflammation were associated with decreased CSF glucose levels in the microbial but not aseptic category. Moreover, elevated CSF protein levels correlated more strongly than the leukocyte count with low CSF glucose levels on initial ( R 2 = 36%, p CSF sampling ( R 2 = 46%, p CSF glucose and CSF-to-serum glucose ratios had similar low sensitivity and moderate-to-high specificity in diagnosing microbial meningitis at thresholds commonly used. The main driver of hypoglycorrhachia appears to be a combination of microbial meningitis with moderate to high degrees of CSF inflammation and proteins, suggesting that the presence of microorganisms capable of catabolizing glucose is a determinant of hypoglycorrhachia in meningitis. A major notable exception is neurosarcoidosis. Low CSF glucose and CSF-to-serum glucose ratios are useful markers for the diagnosis of microbial meningitis.

  17. Is the routine use of intravenous contrast justified in the workup of ...

    African Journals Online (AJOL)

    The indications for the administration of intravenous contrast media to adult patients presenting with firsttime seizures and a normal pre-contrast study are not clear. A retrospective audit of such patients was done and compared with the post-contrast study. In our study sample of 205 patients all the post-contrast scans were ...

  18. Antecedent caloric intake and glucose excursion following a subsequent meal in Type 1 diabetes.

    Science.gov (United States)

    Mehra, Rinku; Raman, Ramesh; Bayless, Margaret L; Sivitz, William I

    2009-12-01

    In the present study, we tested the hypothesis that calories consumed at a prior meal (lunch) may impair glycemic control after a subsequent meal (supper) even if the pre-supper glucose did not differ regardless of the size of the lunch meal. Nine subjects with Type 1 diabetes using continuous subcutaneous (s.c.) insulin infusion (CSII) therapy were studied on two separate days. Lunch (1200 h) was randomly assigned as 25% or 50% of the usual daily intake on alternate study days. The CSII was stopped at 1000 h on the day of the study and glucose was controlled until supper by adjusting the rate of intravenous (i.v.) insulin based on glucose measurements every 15 min. The CSII was restarted 1 h before supper and i.v. insulin discontinued 15 min before the first bite of supper. An identical supper meal and pre-supper s.c. bolus of short-acting insulin were administered on both visits. Pre-supper glycemia was nearly identical on each of the two study days. However, the post-supper glucose area under the curve was 27.5% greater on the day of the antecedent large lunch compared with the small lunch (P = 0.0039). For optimal postprandial glucose control, people with Type 1 diabetes may need to consider not only anticipated meal calories, but also prior food intake, a practice not commonly recommended based on currently used insulin dosing algorithms.

  19. Sensing of Salivary Glucose Using Nano-Structured Biosensors.

    Science.gov (United States)

    Du, Yunqing; Zhang, Wenjun; Wang, Ming L

    2016-03-17

    The anxiety and pain associated with frequent finger pricking has always been troublesome for diabetics measuring blood glucose (BG) in their daily lives. For this reason, a reliable glucose monitoring system that allows noninvasive measurements is highly desirable. Our main objective is to develop a biosensor that can detect low-level glucose in saliva (physiological range 0.5-20 mg/dL). Salivary glucose (SG) sensors were built using a layer-by-layer self-assembly of single-walled carbon nanotubes, chitosan, gold nanoparticles, and glucose oxidase onto a screen-printed platinum electrode. An electrochemical method was utilized for the quantitative detection of glucose in both buffer solution and saliva samples. A standard spectrophotometric technique was used as a reference method to validate the glucose content of each sample. The disposable glucose sensors have a detection limit of 0.41 mg/dL, a sensitivity of 0.24 μA·s·dL·mg(-1), a linear range of 0.5-20 mg/dL in buffer solution, and a response time of 30 s. A study of 10 healthy subjects was conducted, and SG levels between 1.1 to 10.1 mg/dL were successfully detected. The results revealed that the noninvasive SG monitoring could be an alternative for diabetes self-management at home. This paper is not intended to replace regular BG tests, but to study SG itself as an indicator for the quality of diabetes care. It can potentially help patients control and monitor their health conditions, enabling them to comply with prescribed treatments for diabetes.

  20. Computed tomography intravenous cholangiography

    International Nuclear Information System (INIS)

    Nascimento, S.; Murray, W.; Wilson, P.

    1997-01-01

    Indications for direct visualization of the bile ducts include bile duct dilatation demonstrated by ultrasound or computed tomography (CT) scanning, where the cause of the bile duct dilatation is uncertain or where the anatomy of bile duct obstruction needs further clarification. Another indication is right upper quadrant pain, particularly in a post-cholecystectomy patient, where choledocholithiasis is suspected. A possible new indication is pre-operative evaluation prior to laparoscopic cholecystectomy. The bile ducts are usually studied by endoscopic retrograde cholangiopancreatography (ERCP), or, less commonly, trans-hepatic cholangiography. The old technique of intravenous cholangiography has fallen into disrepute because of inconsistent bile-duct opacification. The advent of spiral CT scanning has renewed interest in intravenous cholangiography. The CT technique is very sensitive to the contrast agent in the bile ducts, and angiographic and three-dimensional reconstructions of the biliary tree can readily be obtained using the CT intravenous cholangiogram technique (CT IVC). Seven patients have been studied using this CT IVC technique, between February 1995 and June 1996, and are the subject of the present report. Eight further studies have since been performed. The results suggest that CT IVC could replace ERCP as the primary means of direct cholangiography, where pancreatic duct visualization is not required. (authors)

  1. Incretin physiology beyond glucagon-like peptide 1 and glucose-dependent insulinotropic polypeptide: cholecystokinin and gastrin peptides

    DEFF Research Database (Denmark)

    Rehfeld, J F

    2011-01-01

    and neonatal islets express significant amounts of gastrin, and human as well as porcine islet cells express the gastrin/CCK-B receptor abundantly. Therefore, exogenous gastrin and CCK peptides stimulate insulin and glucagon secretion in man. Accordingly, endogenous hypergastrinaemia is accompanied by islet...... cell hyperplasia and increased insulin secretion. Conventionally, the effect of gastrointestinal hormones on insulin secretion (the incretin effect) has been defined and quantified in relation to oral versus intravenous glucose loadings. Under these unphysiological conditions, the release of gastrin...

  2. Radiation absorbed dose estimates for [1-carbon-11]-glucose in adults: The effects of hyperinsulinemia

    International Nuclear Information System (INIS)

    Powers, W.J.

    1996-01-01

    As preparation for studies of blood-brain glucose transport in diabetes mellitus, radiation absorbed dose estimates from intravenous administration of [1- 11 C]-glucose for 24 internal organs, lens, blood and total body were calculated for three physiologic conditions: euinsulinemic euglycemia, hyperinsulinemic euglycemia and hyperinsulinemic hyperglycemia. Cumulated activities in blood, insulin-independent and insulin-dependent compartments were calculated from blood time-activity curves in normal human volunteers and macaques. Apportionment of cumulated activity to individual organs in insulin-dependent and insulin-independent compartments was based on previously published data. Absorbed doses were calculated with the computer program MIRDOSE 3 for the 70-kg adult phantom. S for blood was calculated separately. The heart wall, lungs and spleen were the organs receiving the highest dose. The effect of hyperinsulinemia was demonstrated by the increase in adsorbed dose to the muscle, heart and blood with a decrease to other internal organs. This effect was more pronounced during hyperinsulinemic hyperglycemia. Hyperinsulinemia produced a decrease in effective dose due to the decrease in cumulated activity in organs with specified weighting factors greater than 0.05. The effective dose per study for [1- 11 C]-glucose is comparable to that reported for 2-deoxy-[2- 18 F]-glucose. 43 refs., 1 fig., 4 tabs

  3. Intentional intravenous mercury injection | Yudelowitz | South African ...

    African Journals Online (AJOL)

    Intravenous mercury injection is rarely seen, with few documented cases. Treatment strategies are not clearly defined for such cases, although a few options do show benefit. This case report describes a 29-year-old man suffering from bipolar disorder, who presented following self-inflicted intravenous injection of mercury.

  4. Intravenous iron-containing products: EMA procrastination.

    Science.gov (United States)

    2014-07-01

    A European reassessment has led to identical changes in the summaries of product characteristics (SPCs) for all intravenous iron-containing products: the risk of serious adverse effects is now highlighted, underlining the fact that intravenous iron-containing products should only be used when the benefits clearly outweigh the harms. Unfortunately, iron dextran still remains on the market despite a higher risk of hypersensitivity reactions than with iron sucrose.

  5. Highest Plasma Phenylalanine Levels in (Very Premature Infants on Intravenous Feeding; A Need for Concern.

    Directory of Open Access Journals (Sweden)

    Ernesto Cortés-Castell

    Full Text Available To analyse the association in newborns between blood levels of phenylalanine and feeding method and gestational age.This observational, cross-sectional study included a sample of 11,829 infants between 2008 and 2013 in a Spanish region. Data were recorded on phenylalanine values, feeding method [breast, formula, mixed (breast plus formula, or partial or fully intravenous feeding], gestational age in weeks (<32, 32-37, ≥37, gender and days since birth at the moment of blood collection. Outcomes were [phenylalanine] and [phenylalanine] ≥95th percentile. Associations were analysed using multivariate models [linear (means difference and logistic regression (adjusted odds ratios].Higher phenylalanine values were associated with lower gestational age (p<0.001 and with intravenous feeding (p<0.001.The degree of prematurity and intravenous feeding influenced the plasma concentration of phenylalanine in the newborn. Caution should be taken in [phenylalanine] for newborns with intravenous feeding, monitoring them carefully. Very preterm infants given the recommended amount of amino acids should also be strictly monitored. These findings should be taken into consideration and call for adapting the amounts to the needs of the infant.

  6. Intravenous Magnesium Sulphate for Analgesia after Caesarean Section: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Andrew McKeown

    2017-01-01

    Full Text Available Objective. To summarise the evidence for use of intravenous magnesium for analgesic effect in caesarean section patients. Background. Postcaesarean pain requires effective analgesia. Magnesium, an N-methyl-D-aspartate receptor antagonist and calcium-channel blocker, has previously been investigated for its analgesic properties. Methods. A systematic search was conducted of PubMed, Scopus, MEDLINE, Cochrane Library, and Google Scholar databases for randomised-control trials comparing intravenous magnesium to placebo with analgesic outcomes in caesarean patients. Results. Ten trials met inclusion criteria. Seven were qualitatively compared after exclusion of three for unclear bias risk. Four trials were conducted with general anaesthesia, while three utilised neuraxial anaesthesia. Five of seven trials resulted in decreased analgesic requirement postoperatively and four of seven resulted in lower serial visual analogue scale scores. Conclusions. Adjunct analgesic agents are utilised to improve analgesic outcomes and minimise opioid side effects. Preoperative intravenous magnesium may decrease total postcaesarean rescue analgesia consumption with few side effects; however, small sample size and heterogeneity of methodology in included trials restricts the ability to draw strong conclusions. Therefore, given the apparent safety and efficacy of magnesium, its role as an adjunct analgesic in caesarean section patients should be further investigated with the most current anaesthetic techniques.

  7. Persistence of disturbed thalamic glucose metabolism in a case of Wernicke-Korsakoff syndrome.

    Science.gov (United States)

    Fellgiebel, Andreas; Scheurich, Armin; Siessmeier, Thomas; Schmidt, Lutz G; Bartenstein, Peter

    2003-10-30

    We report the case of a 40-year-old alcoholic male patient, hospitalized with an acute ataxia of stance and gait, ocular muscle weakness with nystagmus and a global apathetic-confusional state. After admission, an amnestic syndrome with confabulation was also observed and diagnosis of Wernicke-Korsakoff syndrome was made. Under treatment with intravenous thiamine, the patient recovered completely from gaze weakness and ataxia, whereas a severe amnestic syndrome persisted. Fluorodeoxyglucose (FDG) positron emission tomography (PET) showed bilateral thalamic and severe bilateral temporal-parietal hypometabolism resembling a pattern typical for Alzheimer's disease. Longitudinal assessment of the alcohol-abstinent and thiamine-substituted patient revealed improvements of clinical state and neuropsychological performance that were paralleled by recovered cerebral glucose metabolism. In contrast to metabolic rates that increased between 7.1% (anterior cingulate, left) and 23.5% (parietal, left) in cortical areas during a 9-month remission period, thalamic glucose metabolism remained severely disturbed over time (change: left +0.2%, right +0.3%).

  8. Dynamic 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography of liver tumours without blood sampling

    DEFF Research Database (Denmark)

    Keiding, S; Munk, O L; Schiøtt, K M

    2000-01-01

    Positron emission tomography (PET) using 2-[18F]fluoro-2-deoxy-D-glucose (FDG) is a useful diagnostic tool for the detection of tumours. Using dynamic FDG PET, net metabolic clearance of FDG, K, can be calculated by Gjedde-Patlak analysis of the time course of the radioactivity concentrations...... in tissue and arterial blood. We examined whether time-activity curves (TACs) based on arterial blood sampling could be replaced by TACs obtained from the descending aorta in dynamic PET scans of patients with liver tumours. The study was performed in two parts, using data from dynamic liver scans......, and 2.1-8.4:1 (mean, 4.6:1) based on blood sample TACs (P>0.3). We conclude that arterial blood sampling can be replaced by the present AORTA-VOI in the calculation of the net metabolic clearance of FDG in dynamic PET studies of liver tumours in human subjects. Udgivelsesdato: 2000-Apr...

  9. The influence of sodium propionate on blood glucose, insulin and cortisol concentrations in calves of different ages

    Directory of Open Access Journals (Sweden)

    Biljana Radojičić

    2016-01-01

    Full Text Available The process of gluconeogenesis in ruminants is under the direct influence of insulin and glucocorticoid hormones. The goal of this study was to determine the effects of added Na-propionate on the neuroendocrine regulation of blood glucose in calves at three specific physiological periods: on exclusive milk nutrition; on mixed milk and forage nutrition; and with established ruminant digestion. The influence of Na-propionate on blood glucose, insulin and cortisol concentrations was examined in the same 20 female Holstein calves at different stages of forestomach development (15 days, 2 months, and 4 months of age of calves. Group 1 of calves (n = 10 received Na-propionate intravenously; group 2 (n = 10 received Na-propionate mixed in milk. Blood sampling was performed 1 and 3 h after Na-propionate administration. After i.v. administration of Na-propionate, a significant increase (P < 0.05 in blood glucose concentration was observed 1 h after administration only in calves aged 2 and 4 months; blood insulin concentration was significantly higher (P < 0.01 1 and 3 h after i.v. administration in 2-month-old calves; and cortisol concentration increased (P < 0.01 1 h after administration in each selected calf in all testing periods. Orally administered Na-propionate led to a significant increase (P < 0.01 of insulin concentration 1 and 3 h after administration in 15-day-old calves, and 3 h after administration in 2-month-old calves. Based on these results it could be assumed that i.v. and p.o. administration of Na-propionate affects the neuroendocrine regulation of glycaemia in calves of different age.

  10. Effect of intravenous administration of dextrose or lactated Ringer's solution on seizure development in dogs after cervical myelography with metrizamide

    International Nuclear Information System (INIS)

    Gray, P.R.; Lowrie, C.T.; Wetmore, L.A.

    1987-01-01

    The effect of fluid (5% dextrose in water or lactated Ringer's solution) administered intravenously on the development of seizures after cervical myelography with metrizamide was studied in 10 dogs. In a crossover experimental design, 8 dogs were used twice. Urine output was measured during the second part of the study to determine whether diuresis was a factor affecting seizure development. Dogs given 5% dextrose in water had significantly (P less than 0.05) fewer seizures than did dogs given lactated Ringer's solution. This was attributed to an increase in CSF glucose concentration and was not associated with diuresis

  11. Biosynthesis and Characterization of Glucose Syrup Derived from ...

    African Journals Online (AJOL)

    In order to characterize the prepared glucose syrups, Fehling test, Biuret test, glucose concentration (GC), dextrose equivalent (DE), relative density (RD), pH, viscosity and surface tension (ST) were determined. Granular size range of 7 – 15 μm and moisture content of 12 % were determined for the untreated starch sample.

  12. Technical note: comparison of 3 methods for analyzing areas under the curve for glucose and nonesterified fatty acids concentrations following epinephrine challenge in dairy cows.

    Science.gov (United States)

    Cardoso, F C; Sears, W; LeBlanc, S J; Drackley, J K

    2011-12-01

    The objective of the study was to compare 3 methods for calculating the area under the curve (AUC) for plasma glucose and nonesterified fatty acids (NEFA) after an intravenous epinephrine (EPI) challenge in dairy cows. Cows were assigned to 1 of 6 dietary niacin treatments in a completely randomized 6 × 6 Latin square with an extra period to measure carryover effects. Periods consisted of a 7-d (d 1 to 7) adaptation period followed by a 7-d (d 8 to 14) measurement period. On d 12, cows received an i.v. infusion of EPI (1.4 μg/kg of BW). Blood was sampled at -45, -30, -20, -10, and -5 min before EPI infusion and 2.5, 5, 10, 15, 20, 30, 45, 60, 90, and 120 min after. The AUC was calculated by incremental area, positive incremental area, and total area using the trapezoidal rule. The 3 methods resulted in different statistical inferences. When comparing the 3 methods for NEFA and glucose response, no significant differences among treatments and no interactions between treatment and AUC method were observed. For glucose and NEFA response, the method was statistically significant. Our results suggest that the positive incremental method and the total area method gave similar results and interpretation but differed from the incremental area method. Furthermore, the 3 methods evaluated can lead to different results and statistical inferences for glucose and NEFA AUC after an EPI challenge. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  13. Molecular Weight Dependent Glucose Lowering Effect of Low Molecular Weight Chitosan Oligosaccharide (GO2KA1 on Postprandial Blood Glucose Level in SD Rats Model

    Directory of Open Access Journals (Sweden)

    Emmanouil Apostolidis

    2013-07-01

    Full Text Available This research investigated the effect of enzymatically digested low molecular weight (MW chitosan oligosaccharide on type 2 diabetes prevention. Three different chitosan oligosaccharide samples with varying MW were evaluated in vitro for inhibition of rat small intestinal α-glucosidase and porcine pancreatic α-amylase (GO2KA1; 10,000 Da. The in vitro results showed that all tested samples had similar rat α-glucosidase inhibitory and porcine α-amylase inhibitory activity. Based on these observations, we decided to further investigate the effect of all three samples at a dose of 0.1 g/kg, on reducing postprandial blood glucose levels in Sprague-Dawley (SD rat model after sucrose loading test. In the animal trial, all tested samples had postprandial blood glucose reduction effect, when compared to control, however GO2KA1 supplementation had the strongest effect. The glucose peak (Cmax for GO2KA1 and control was 152 mg/dL and 193 mg/dL, respectively. The area under the blood glucose-time curve (AUC for GO2KA1 and control was 262 h mg/dL and 305 h mg/dL, respectively. Furthermore, the time of peak plasma concentration of blood glucose (Tmax for GO2KA1 was significantly delayed (0.9 h compared to control (0.5 h. These results suggest that GO2KA1 could have a beneficial effect for blood glucose management relevant to diabetes prevention in normal and pre-diabetic individuals. The suggested mechanism of action is via inhibition of the carbohydrate hydrolysis enzyme α-glucosidase and since GO2KA1 (MW < 1000 Da had higher in vivo effect, we hypothesize that it is more readily absorbed and might exert further biological effect once it is absorbed in the blood stream, relevant to blood glucose management.

  14. Xanthene derivatives increase glucose utilization through activation of LKB1-dependent AMP-activated protein kinase.

    Directory of Open Access Journals (Sweden)

    Yonghoon Kwon

    Full Text Available 5' AMP-activated protein kinase (AMPK is a highly conserved serine-threonine kinase that regulates energy expenditure by activating catabolic metabolism and suppressing anabolic pathways to increase cellular energy levels. Therefore AMPK activators are considered to be drug targets for treatment of metabolic diseases such as diabetes mellitus. To identify novel AMPK activators, we screened xanthene derivatives. We determined that the AMPK activators 9H-xanthene-9-carboxylic acid {2,2,2-trichloro-1-[3-(3-nitro-phenyl-thioureido]-ethyl}-amide (Xn and 9H-xanthene-9-carboxylic acid {2,2,2-trichloro-1-[3-(3-cyano-phenyl-thioureido]-ethyl}-amide (Xc elevated glucose uptake in L6 myotubes by stimulating translocation of glucose transporter type 4 (GLUT4. Treatment with the chemical AMPK inhibitor compound C and infection with dominant-negative AMPKa2-virus inhibited AMPK phosphorylation and glucose uptake in myotubes induced by either Xn or Xc. Of the two major upstream kinases of AMPK, we found that Xn and Xc showed LKB1 dependency by knockdown of STK11, an ortholog of human LKB1. Single intravenous administration of Xn and Xc to high-fat diet-induced diabetic mice stimulated AMPK phosphorylation of skeletal muscle and improved glucose tolerance. Taken together, these results suggest that Xn and Xc regulate glucose homeostasis through LKB1-dependent AMPK activation and that the compounds are potential candidate drugs for the treatment of type 2 diabetes mellitus.

  15. Mediatorless amperometric bienzyme glucose biosensor based on horseradish peroxidase and glucose oxidase cross-linked to multiwall carbon nanotubes

    International Nuclear Information System (INIS)

    Xu, Shuxia; Zhou, Shiyi; Zhang, Xinfeng; Qi, Honglan; Zhang, Chengxiao

    2014-01-01

    We report on a bienzyme-channeling sensor for sensing glucose without the aid of mediator. It was fabricated by cross-linking horseradish peroxidase (HRP) and glucose oxidase (GOx) on a glassy carbon electrode modified with multiwalled carbon nanotubes (MWNTs). The bienzyme was cross-linked with the MWNTs by glutaraldehyde and bovine serum albumin. The MWNTs were employed to accelerate the electron transfer between immobilized HRP and electrode. Glucose was sensed by amperometric reduction of enzymatically generated H 2 O 2 at an applied voltage of −50 mV (vs. Ag/AgCl). Factors influencing the preparation and performance of the bienzyme electrode were investigated in detail. The biosensor exhibited a fast and linear response to glucose in the concentration range from 0.4 to 15 mM, with a detection limit of 0.4 mM. The sensor exhibited good selectivity and durability, with a long-term relative standard deviation of <5 %. Analysis of glucose-spiked human serum samples yielded recoveries between 96 and 101 %. (author)

  16. Continuous subcutaneous infusion of glucagon-like peptide 1 lowers plasma glucose and reduces appetite in type 2 diabetic patients

    DEFF Research Database (Denmark)

    Toft-Nielsen, M B; Madsbad, Sten; Holst, J J

    1999-01-01

    OBJECTIVE: The gut hormone glucagon-like peptide 1 (GLP-1) has insulinotropic and anorectic effects during intravenous infusion and has been proposed as a new treatment for type 2 diabetes and obesity. The effect of a single subcutaneous injection is brief because of rapid degradation. We therefore......, previously shown to lower blood glucose effectively in type 2 diabetic patients. Fasting plasma glucose (day 2) decreased from 14.1 +/- 0.9 (saline) to 12.2 +/- 0.7 mmol/l (GLP-1), P = 0.009, and 24-h mean plasma glucose decreased from 15.4 +/- 1.0 to 13.0 +/- 1.0 mmol/l, P = 0.0009. Fasting and total area...... under the curve for insulin and C-peptide levels were significantly higher during the GLP-1 administration, whereas glucagon levels were unchanged. Neither triglycerides nor free fatty acids were affected. GLP-1 administration decreased hunger and prospective food intake and increased satiety, whereas...

  17. Accuracy evaluation of contour next compared with five blood glucose monitoring systems across a wide range of blood glucose concentrations occurring in a clinical research setting.

    Science.gov (United States)

    Klaff, Leslie J; Brazg, Ronald; Hughes, Kristen; Tideman, Ann M; Schachner, Holly C; Stenger, Patricia; Pardo, Scott; Dunne, Nancy; Parkes, Joan Lee

    2015-01-01

    This study evaluated the accuracy of Contour(®) Next (CN; Bayer HealthCare LLC, Diabetes Care, Whippany, NJ) compared with five blood glucose monitoring systems (BGMSs) across a wide range of clinically occurring blood glucose levels. Subjects (n=146) were ≥ 18 years and had type 1 or type 2 diabetes. Subjects' glucose levels were safely lowered or raised to provide a wide range of glucose values. Capillary blood samples were tested on six BGMSs and a YSI glucose analyzer (YSI Life Sciences, Inc., Yellow Springs, OH) as the reference. Extreme glucose values were achieved by glucose modification of the blood sample. System accuracy was assessed by mean absolute difference (MAD) and mean absolute relative difference (MARD) across several glucose ranges, with glucose range (Abbott Diabetes Care, Inc., Alameda, CA), 2.77 mg/dL; OneTouch(®) Ultra(®) 2 (LifeScan, Inc., Milpitas, CA), 10.20 mg/dL; OneTouch(®) Verio(®) Pro (LifeScan, Inc.), 4.53 mg/dL; and Truetrack(®) (Nipro Diagnostics, Inc., Fort Lauderdale, FL), 11.08 mg/dL. The lowest MAD in the low glucose range, from CN, was statistically significantly lower than those of the other BGMSs with the exception of the FSL. CN also had a statistically significantly lower MARD than all other BGMSs in the low glucose range. In the overall glucose range (21-496 mg/dL), CN yielded the lowest MAD and MARD values, which were statistically significantly lower in comparison with the other BGMSs. When compared with other BGMSs, CN demonstrated the lowest mean deviation from the reference value (by MAD and MARD) across multiple glucose ranges.

  18. Impaired fasting glucose and impaired glucose tolerance in children and adolescents with overweight/obesity.

    Science.gov (United States)

    Di Bonito, P; Pacifico, L; Chiesa, C; Valerio, G; Miraglia Del Giudice, E; Maffeis, C; Morandi, A; Invitti, C; Licenziati, M R; Loche, S; Tornese, G; Franco, F; Manco, M; Baroni, M G

    2017-04-01

    To investigate in a large sample of overweight/obese (OW/OB) children and adolescents the prevalence of prediabetic phenotypes such as impaired fasting glucose (IFG) and impaired glucose tolerance (IGT), and to assess their association with cardiometabolic risk (CMR) factors including hepatic steatosis (HS). Population data were obtained from the CARdiometabolic risk factors in children and adolescents in ITALY study. Between 2003 and 2013, 3088 youths (972 children and 2116 adolescents) received oral glucose tolerance test (OGTT) and were included in the study. In 798 individuals, abdominal ultrasound for identification of HS was available. The prevalence of IFG (3.2 vs. 3.3%) and IGT (4.6 vs. 5.0%) was similar between children and adolescents. Children with isolated IGT had a 2-11 fold increased risk of high LDL-C, non-HDL-C, Tg/HDL-C ratio, and low insulin sensitivity, when compared to those with normal glucose tolerance (NGT). No significant association of IFG with any CMR factor was found in children. Among adolescents, IGT subjects, and to a lesser extent those with IFG, showed a worse CMR profile compared to NGT subgroup. In the overall sample, IGT phenotype showed a twofold increased risk of HS compared to NGT subgroup. Our study shows an unexpected similar prevalence of IFG and IGT between children and adolescents with overweight/obesity. The IGT phenotype was associated with a worse CMR profile in both children and adolescents. Phenotyping prediabetes conditions by OGTT should be done as part of prediction and prevention of cardiometabolic diseases in OW/OB youth since early childhood.

  19. Mediation of Endogenous β-Endorphin by Tetrandrine to Lower Plasma Glucose in Streptozotocin-Induced Diabetic Rats

    Directory of Open Access Journals (Sweden)

    Jen-Hao Hsu

    2004-01-01

    Full Text Available The role of β-endorphin in the plasma glucose-lowering action of tetrandrine in streptozotocin-induced diabetic rats (STZ-diabetic rats was investigated. The plasma glucose concentration was assessed by the glucose oxidase method. The enzyme-linked immunosorbent assay was used to determine the plasma level of β-endorphin-like immunoreactivity (BER. The mRNA levels of glucose transporter subtype 4 (GLUT4 in soleus muscle and phosphoenolpyruvate carboxykinase (PEPCK in the liver of STZ-diabetic rats were detected by Northern blotting analysis. The expressed protein of GLUT4 or PEPCK was characterized by Western blotting analysis. Tetrandrine dose-dependently increased plasma BER in a manner parallel to the decrease of plasma glucose in STZ-diabetic rats. Moreover, the plasma glucose-lowering effect of tetrandrine was inhibited by naloxone and naloxonazine at doses sufficient to block opioid μ-receptors. Further, tetrandrine failed to produce plasma glucose-lowering action in opioid μ-receptor knockout diabetic mice. Bilateral adrenalectomy eliminated the plasma glucose-lowering effect and plasma BER-elevating effect of tetrandrine in STZ-diabetic rats. Both effects were abolished by treatment with hexamethonium or pentolinium at doses sufficient to block nicotinic receptors. Tetrandrine enhanced BER release directly from the isolated adrenal medulla of STZ-diabetic rats and this action was abolished by the blockade of nicotinic receptors. Repeated intravenous administration of tetrandrine (1.0 mg/kg to STZ-diabetic rats for 3 days resulted in an increase in the mRNA and protein levels of the GLUT4 in soleus muscle, in addition to the lowering of plasma glucose. Similar treatment with tetrandrine reversed the elevated mRNA and protein levels of PEPCK in the liver of STZ-diabetic rats. The obtained results suggest that tetrandrine may induce the activation of nicotinic receptors in adrenal medulla to enhance the secretion of

  20. Dynamic glucose enhanced (DGE) MRI for combined imaging of blood-brain barrier break down and increased blood volume in brain cancer.

    Science.gov (United States)

    Xu, Xiang; Chan, Kannie W Y; Knutsson, Linda; Artemov, Dmitri; Xu, Jiadi; Liu, Guanshu; Kato, Yoshinori; Lal, Bachchu; Laterra, John; McMahon, Michael T; van Zijl, Peter C M

    2015-12-01

    Recently, natural d-glucose was suggested as a potential biodegradable contrast agent. The feasibility of using d-glucose for dynamic perfusion imaging was explored to detect malignant brain tumors based on blood brain barrier breakdown. Mice were inoculated orthotopically with human U87-EGFRvIII glioma cells. Time-resolved glucose signal changes were detected using chemical exchange saturation transfer (glucoCEST) MRI. Dynamic glucose enhanced (DGE) MRI was used to measure tissue response to an intravenous bolus of d-glucose. DGE images of mouse brains bearing human glioma showed two times higher and persistent changes in tumor compared with contralateral brain. Area-under-curve (AUC) analysis of DGE delineated blood vessels and tumor and had contrast comparable to the AUC determined using dynamic contrast enhanced (DCE) MRI with GdDTPA, both showing a significantly higher AUC in tumor than in brain (P blood volume and permeability with respect to normal brain. We expect DGE will provide a low-risk and less expensive alternative to DCE MRI for imaging cancer in vulnerable populations, such as children and patients with renal impairment. © 2015 Wiley Periodicals, Inc.

  1. Dynamic Glucose Enhanced (DGE) MRI for Combined Imaging of Blood Brain Barrier Break Down and Increased Blood Volume in Brain Cancer

    Science.gov (United States)

    Xu, Xiang; Chan, Kannie WY; Knutsson, Linda; Artemov, Dmitri; Xu, Jiadi; Liu, Guanshu; Kato, Yoshinori; Lal, Bachchu; Laterra, John; McMahon, Michael T.; van Zijl, Peter C.M.

    2015-01-01

    Purpose Recently, natural d-glucose was suggested as a potential biodegradable contrast agent. The feasibility of using d-glucose for dynamic perfusion imaging was explored to detect malignant brain tumors based on blood brain barrier breakdown. Methods Mice were inoculated orthotopically with human U87-EGFRvIII glioma cells. Time-resolved glucose signal changes were detected using chemical exchange saturation transfer (glucoCEST) MRI. Dynamic glucose enhanced (DGE) MRI was used to measure tissue response to an intravenous bolus of d-glucose. Results DGE images of mouse brains bearing human glioma showed two times higher and persistent changes in tumor compared to contralateral brain. Area-under-curve (AUC) analysis of DGE delineated blood vessels and tumor and had contrast comparable to the AUC determined using dynamic contrast enhanced (DCE) MRI with GdDTPA, both showing a significantly higher AUC in tumor than in brain (pblood volume and permeability with respect to normal brain. We expect DGE will provide a low-risk and less expensive alternative to DCE MRI for imaging cancer in vulnerable populations, such as children and patients with renal impairment. PMID:26404120

  2. Comparison of glucose concentration and glucose absorption from the GI-tract in pigs in whole blood and in plasma

    DEFF Research Database (Denmark)

    Theil, Peter Kappel; Jørgensen, Henry; Larsen, Torben

    2010-01-01

    using a biosensitive electrode (Exp. 1) or a standard colourimetric method (Exp. 2). In general, glucose measured in whole blood was 7-11% lower than in plasma at low glucose levels (3.5-5 mM), whereas the methods agreed well at high glucose levels (10-14 mM). Evaluation of the regression lines between......The present investigation was undertaken to compare glucose absorption from the gastro-intestinal tract quantified in either whole blood or plasma using the arterio-venous differences and portal blood flow measurements. Pigs were surgically modified with catheters in the portal vein...... three different diets with similar contents of starch (470-506 g/kg DM). The diets in both studies differed regarding amount and solubility of fibre. Blood samples were collected repeatedly 0-10 h after morning feeding. Glucose was measured in whole blood using a glucometer (Accu-Chek®) and in plasma...

  3. Green Chemistry Glucose Biosensor Development using Etlingera elatior Extract

    Science.gov (United States)

    Fatoni, A.; Anggraeni, M. D.; Zusfahair; Iqlima, H.

    2018-01-01

    Glucose biosensor development is one of the important strategies for early detection of diabetes mellitus disease. This study was aimed to explore the flower extract of Etlingera elatior for a green-analysis method of glucose biosensor. Flowers were extracted using ethanol: HCl and tested its performances as an indicator of glucose biosensor using glucose oxidase enzyme. The glucose oxidase react with glucose resulted hydrogen peroxide that would change the color of the flower extract. Furthermore, the extract was also studied including their stability to pH, oxidizing and reducing, temperature, and storage. The results showed that the Etlingera elatior extract had high correlation between color change and glucose concentration with regression equation of y = -0.0005x + 0.4724 and R2 of 0.9965. The studied biosensor showed a wide linear range to detect glucose sample of 0 to 500 mM. The extract characterization showed a more stable in low pH (acid), reducing agent addition, heating treatment and storage.

  4. Microbiological quality of some brands of intravenous fluids ...

    African Journals Online (AJOL)

    Microbiological quality of some brands of intravenous fluids produced by some pharmaceutical companies in Nigeria was investigated. Membrane filtration method was used for concentration of contaminating organisms in the intravenous fluids. Thioglycollate medium, Tryptone Soya broth, Brilliant Green Agar ...

  5. Immobilization of Glucose Oxidase on a Carbon Nanotubes/Dendrimer-Ferrocene Modified Electrode for Reagentless Glucose Biosensing.

    Science.gov (United States)

    Zhou, Juan; Li, Huan; Yang, Huasong; Cheng, Hui; Lai, Guosong

    2017-01-01

    Ferrocene-grafted dendrimer was covalently linked to the surface of a carbon nanotubes (CNTs)-chitosan (CS) nanocomposite modified electrode for immobilizing high-content glucose oxidase (GOx), which resulted in the successful development a novel reagentless glucose biosensor. Electrochemical impedance spectroscopy, cyclic voltammetry, and amperometry were used to characterize the preparation process and the enzymatically catalytic response of this biosensor. Due to the excellent electron transfer acceleration of the CNTs and the high-content loading of the GOx biomolecule and ferrocene mediator on the electrode matrix, this biosensor showed excellent analytical performance such as fast response time less than 10 s, wide linear range from 0.02 to 2.91 mM and low detection limit down to 7.5 μM as well as satisfactory stability and reproducibility toward the amperometric glucose determination. In addition, satisfactory result was obtained when it was used for the glucose measurements in human blood samples. Thus this biosensor provides great potentials for practical applications.

  6. Screening of gingival crevicular blood glucose and capillary finger blood glucose in the diagnosis of diabetes

    Directory of Open Access Journals (Sweden)

    Alka S Waghmare

    2011-01-01

    Full Text Available Aim: The study aimed at obtaining glucose readings using gingival crevicular blood (GCB to screen for undiagnosed diabetes during routine dental visits. Materials and Methods: The present study included 50 patients who were divided into two groups, i.e. Group A and Group B, based on bleeding on probing at the site of collection of GCB. Group A participants had blood collected from sites having adequate bleeding on probing, whereas Group B participants had blood collected from sites with little bleeding on probing. GCB and capillary finger-stick blood (CFB] glucose readings were obtained using a self-monitoring glucometer. Statistical Analysis: Correlations between both the samples were done using Pearson′s correlation. Results: Group A patients′ correlations between GCB and CFB glucose readings were high, whereas in Group B patients, correlations between glucose readings were low. Conclusion: GCB can be an excellent source for screening diabetes during routine dental visits.

  7. Administration costs of intravenous biologic drugs for rheumatoid arthritis

    OpenAIRE

    Soini, Erkki J; Leussu, Miina; Hallinen, Taru

    2013-01-01

    Background Cost-effectiveness studies explicitly reporting infusion times, drug-specific administration costs for infusions or real-payer intravenous drug cost are few in number. Yet, administration costs for infusions are needed in the health economic evaluations assessing intravenously-administered drugs. Objectives To estimate the drug-specific administration and total cost of biologic intravenous rheumatoid arthritis (RA) drugs in the adult population and to compare the obtained costs wit...

  8. The association between Western and Prudent dietary patterns and fasting blood glucose levels in type 2 diabetes and normal glucose metabolism in older Australian adults.

    Science.gov (United States)

    Walsh, Erin I; Jacka, Felice N; Butterworth, Peter; Anstey, Kaarin J; Cherbuin, Nicolas

    2017-06-01

    High blood glucose and type 2 diabetes are associated with a range of adverse health and cognitive outcomes. One factor that contributes to high blood glucose and type 2 diabetes is dietary intake. This study investigated the relationship between dietary patterns, fasting blood glucose and diabetes status in a sample of 209 participants aged 60-65. Blood plasma glucose was measured from venous blood samples. Individual Prudent and Western dietary patterns were estimated from a self-completed food frequency questionnaire. The relationship between dietary patterns, diabetes, and blood glucose was assessed via general linear model analyses controlling for age, sex, height, and total caloric intake. Results indicated that there was no association between Prudent diet and fasting blood glucose levels, or type 2 diabetes. In contrast, an individual in the upper tertile for Western dietary score had a significantly higher risk of having diabetes than an individual in the lower tertile for Western dietary score. However, there was no significant association between Western diet and fasting blood glucose. Western diet may be associated with type 2 diabetes through mechanisms beyond impacting blood plasma glucose directly. The fact that the association between Western diet and type 2 diabetes remained even when total caloric intake was controlled for highlights the need for policy and population health interventions targeting the reduction of unhealthy food consumption.

  9. Low-dose intravenous lidocaine as treatment for proctalgia fugax.

    Science.gov (United States)

    Peleg, Roni; Shvartzman, Pesach

    2002-01-01

    Proctalgia fugax is characterized by a sudden internal anal sphincter and anorectic ring attack of pain of a short duration. Description of the influence of intravenous lidocaine treatment for proctalgia fugax. A 28-year-old patient suffering of proctalgia fugax for 8 months. Conventional treatment efforts did not improve his condition. A single dose of an intravenous lidocaine infusion completely stopped his pain attacks. Based on the experience reported in this case and the potential benefit of this treatment for proctalgia fugax, controlled studies comparing intravenous lidocaine with placebo should be conducted to confirm the observation and to provide a more concrete basis for the use of intravenous lidocaine for this indication.

  10. Fasting glucose and cardiovascular risk factors in an urban population.

    Science.gov (United States)

    Gupta, R; Sarna, M; Thanvi, Jyoti; Sharma, Vibha; Gupta, V P

    2007-10-01

    To test the hypothesis that blood glucose levels in the range of normoglycemia are associated with increased cardiovascular risk we performed an epidemiological study in an urban population. Randomly selected adults > or = 20 years were studied using stratified sampling. Target sample was 1800 (men 960, women 840) of which 1123 subjects participated. Blood samples were available in 1091 subjects (60.6%, men 532, women 559). Measurement of anthropometric variables, blood pressure, fasting blood glucose and lipids was performed. Cardiovascular risk factors were determined using US Adult Treatment Panel-3 guidelines. Pearson's correlation coefficients (r) of fasting glucose with various risk factors were determined. Fasting glucose levels were classified into various groups as 126 mg/dl or known diabetes. Prevalence of cardiovascular risk factors was determined in each group. There was a significant positive correlation of fasting glucose in men and women with body mass index (r = 0.20, 0.12), waist-hip ratio (0.17, 0.09), systolic blood pressure (0.07, 0.22), total cholesterol (0.21, 0.15) and triglycerides (0.21, 0.25). Prevalence (%) of cardiovascular risk factors in men and women was smoking/tobacco use in 37.6 and 11.6, hypertension in 37.0 and 37.6, overweight and obesity in 37.8 and 50.3, truncal obesity in 57.3 and 68.0, high cholesterol > or = 200 mg/dl in 37.4 and 45.8, high triglycerides > or = 150 mg/dl in 32.3 and 28.6 and metabolic syndrome in 22.9 and 31.6 percent. In various groups of fasting glucose there was an increasing trend in prevalence of overweight/obesity, hypertension, hypercholesterolaemia, hypertriglyceridaemia, and metabolic syndrome (Mantel-Haenzel X2 for trend, p fasting glucose continuous relationship of fasting glucose levels with many cardiovascular risk factors and level < 75 mg/dl is associated with the lowest prevalence.

  11. Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System.

    Science.gov (United States)

    Kropff, Jort; van Steen, Sigrid C; deGraaff, Peter; Chan, Man W; van Amstel, Rombout B E; DeVries, J Hans

    2017-11-01

    Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. We evaluated 21 individuals with type 1 diabetes using a capillary calibrated CGM system. Venous or arterialized-venous reference glucose samples were taken every 15 min at two separate visits and assessed per YSI 2300 STAT Plus. Arterialization was achieved by heated-hand technique. Capillary samples were collected hourly during the venous reference visit. The investigation sequence (venous or arterialized-venous) was randomized. Effectiveness of arterialization was measured by comparing free venous oxygen pressure (PO2) of both visit days. Primary endpoint was the median absolute relative difference (ARD). Median ARD using arterialized-venous reference samples was not different from venous samples (point estimated difference 0.52%, P = 0.181). When comparing the three reference methods, median ARD was also not different over the full glycemic range (venous 9.0% [n = 681], arterialized-venous 8.3% [n = 684], and capillary 8.1% [n = 205], P = 0.216), nor over the separate glucose ranges. Arterialization was successful (PO2 venous 5.4 kPa vs. arterialized-venous 8.9 kPa, P reference measurements did not significantly impact CGM accuracy. Venous reference seems preferable due to its ease of operation.

  12. Sup(13)C NMR studies of glucose disposal in normal and non-insulin-dependent diabetic humans

    International Nuclear Information System (INIS)

    Shulman, G.I.; Rothman, D.L.; Shulman, R.G.

    1990-01-01

    To examine the extent to which the defect in insulin action in subjects with non-insulin-dependent diabetes mellitus (NIDDM) can be accounted for by impairment of muscle glycogen synthesis, we performed combined hyperglycemic-hyperinsulinemic clamp studies with [ 13 C]glucose in five subjects with NIDDM and in six age- and weight-matched healthy subjects. The rate of incorporation of intravenously infused [1- 13 C]glucose into muscle glycogen was measured directly in the gastrocnemius muscle by means of a nuclear magnetic resonance (NMR) spectrometer with a 15.5 min time resolution and a 13 C surface coil. The steady-state plasma concentrations of insulin and glucose were similar in both study groups. The mean (±SE) rate of glycogen synthesis, as determined by 13 C NMR, was 78±28 and 183±39 μmol-glucosyl units (kg muscle tissue (wet mass)) -1 min -1 in the diabetic and normal subjects, respectively. The mean glucose uptake was markedly reduced in the diabetic as compared with the normal subjects. The mean rate of non-oxidative glucose metabolism was 22±4 μmol kg -1 min -1 in the diabetic subjects and 42±4 μmol kg -1 min -1 in the normal subjects. When these rates are extrapolated to apply to the whole body, the synthesis of muscle glycogen would account for most of the total-body glucose uptake and all of the non-oxidative glucose metabolism in both normal and diabetic subjects. We conclude that muscle glycogen synthesis is the principal pathway of glucose disposal in both normal and diabetic subjects and that defects in muscle glycogen synthesis have a dominant role in the insulin resistance that occurs in persons with NIDDM. (author)

  13. Methods of preparing and using intravenous nutrient compositions

    International Nuclear Information System (INIS)

    Beigler, M.A.; Koury, A.J.

    1983-01-01

    A method for preparing a stable, dry-packaged, sterile, nutrient composition which upon addition of sterile, pyrogen-free water is suitable for intravenous administration to a mammal, including a human, is described. The method comprises providing the nutrients in a specific dry form and state of physical purity acceptable for intravenous administration, sealing the nutrients in a particular type of container adapted to receive and dispense sterile fluids and subjecting the container and its sealed contents to a sterilizing, nondestructive dose of ionizing radiation. The method results in a packaged, sterile nutrient composition which may be dissolved by the addition of sterile pyrogen-free water. The resulting aqueous intravenous solution may be safely administered to a mammal in need of nutrient therapy. The packaged nutrient compositions of the invention exhibit greatly extended storage life and provide an economical method of providing intravenous solutions which are safe and efficacious for use. (author)

  14. Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients

    OpenAIRE

    Uemura, Mei

    2017-01-01

    Background: Continuous glucose monitoring (CGM) is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC) monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET). Here we evaluated the accuracy of interstitial fluid glucose (IG) AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting h...

  15. Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients

    OpenAIRE

    Mei Uemura; Yutaka Yano; Toshinari Suzuki; Taro Yasuma; Toshiyuki Sato; Aya Morimoto; Samiko Hosoya; Chihiro Suminaka; Hiromu Nakajima; Esteban C. Gabazza; Yoshiyuki Takei

    2017-01-01

    Background Continuous glucose monitoring (CGM) is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC) monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET). Here we evaluated the accuracy of interstitial fluid glucose (IG) AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting hy...

  16. Glucose Sensing

    CERN Document Server

    Geddes, Chris D

    2006-01-01

    Topics in Fluorescence Spectroscopy, Glucose Sensing is the eleventh volume in the popular series Topics in Fluorescence Spectroscopy, edited by Drs. Chris D. Geddes and Joseph R. Lakowicz. This volume incorporates authoritative analytical fluorescence-based glucose sensing reviews specialized enough to be attractive to professional researchers, yet also appealing to the wider audience of scientists in related disciplines of fluorescence. Glucose Sensing is an essential reference for any lab working in the analytical fluorescence glucose sensing field. All academics, bench scientists, and industry professionals wishing to take advantage of the latest and greatest in the continuously emerging field of glucose sensing, and diabetes care & management, will find this volume an invaluable resource. Topics in Fluorescence Spectroscopy Volume 11, Glucose Sensing Chapters include: Implantable Sensors for Interstitial Fluid Smart Tattoo Glucose Sensors Optical Enzyme-based Glucose Biosensors Plasmonic Glucose Sens...

  17. USE OF A COMPUTER-GUIDED GLUCOSE MANAGEMENT SYSTEM TO IMPROVE GLYCEMIC CONTROL AND ADDRESS NATIONAL QUALITY MEASURES: A 7-YEAR, RETROSPECTIVE OBSERVATIONAL STUDY AT A TERTIARY CARE TEACHING HOSPITAL.

    Science.gov (United States)

    Tanenberg, Robert J; Hardee, Sandra; Rothermel, Caitlin; Drake, Almond J

    2017-03-01

    Inpatient hyperglycemia, hypoglycemia, and glucose variability are associated with increased mortality. The use of an electronic glucose management system (eGMS) to guide intravenous (IV) insulin infusion has been found to significantly improve blood glucose (BG) control. This retrospective observational study evaluated the 7-year (January 2009-December 2015) impact of the EndoTool ® eGMS in intensive and intermediate units at Vidant Medical Center, a 900-bed tertiary teaching hospital. Patients assigned to eGMS had indications for IV insulin infusion, including uncontrolled diabetes, stress hyperglycemia, and/or postoperative BG levels >140 mg/dL. This study evaluated time required to achieve BG control (180 mg/dL after control attained); and the impact of eGMS on hospital-acquired condition (HAC)-8 rates. Data were available for all treated patients (492,078 BG readings from 16,850 patients). With eGMS, BG levels were brought to target within 1.5 to 2.3 hours (4.5 to 4.8 hours for cardiovascular patients). Minimal hypoglycemia was observed (BG values 180 mg/dL once control was attained). HAC-8 rates were reduced from 0.083 per 1,000 patients (2008) to 0.032 per 1,000 patients (2011). The use of eGMS resulted in rapid, effective control of inpatient BG levels, including significantly reduced hypoglycemia rates. BG = blood glucose CMS = Centers for Medicare and Medicaid Services CV = coefficient of variation CV% = coefficient of variation percentage eGMS = electronic glucose management system GV = glycemic variability HAC = Hospital-Acquired Condition ICU = intensive care unit IU = intermediate unit IV = intravenous LOS = length of stay VMC = Vidant Medical Center.

  18. Cost-minimization of mabthera intravenous versus subcutaneous administration

    NARCIS (Netherlands)

    Bax, P.; Postma, M.J.

    2013-01-01

    Objectives: To identify and compare all costs related to preparing and administrating MabThera for the intravenous and subcutaneous formulations in Dutch hematological patients. The a priori notion is that the costs of subcutaneous MabThera injections are lower compared to intravenous infusion due

  19. Phlebitis associated with peripheral intravenous catheters in adults admitted to hospital in the Western Brazilian Amazon

    Directory of Open Access Journals (Sweden)

    Sandra Maria Sampaio Enes

    2016-04-01

    Full Text Available Abstract OBJECTIVE To identify the presence of phlebitis and the factors that influence the development of this complication in adult patients admitted to hospital in the western Brazilian Amazon. METHOD Exploratory study with a sample of 122 peripheral intravenous catheters inserted in 122 patients in a medical unit. Variables related to the patient and intravenous therapy were analyzed. For the analysis, we used chi-square tests of Pearson and Fisher exact test, with 5% significance level. RESULTS Complication was the main reason for catheter removal (67.2%, phlebitis was the most frequent complication (31.1%. The mean duration of intravenous therapy use was 8.81 days in continuous and intermittent infusion (61.5%, in 20G catheter (39.3%, inserted in the dorsal hand vein arc (36.9 %, with mean time of usage of 68.4 hours. The type of infusion (p=0.044 and the presence of chronic disease (p=0.005 and infection (p=0.007 affected the development of phlebitis. CONCLUSION There was a high frequency of phlebitis in the sample, being influenced by concomitant use of continuous and intermittent infusion of drugs and solutions, and more frequent in patients with chronic diseases and infection.

  20. Single-dose intravenous iron infusion versus red blood cell transfusion for the treatment of severe postpartum anaemia

    DEFF Research Database (Denmark)

    Holm, C; Thomsen, L L; Norgaard, A

    2017-01-01

    BACKGROUND AND OBJECTIVES: There are no randomized trials comparing intravenous iron to RBC transfusion for the treatment of severe postpartum anaemia. The objectives of this study were to evaluate the feasibility of randomizing women with severe postpartum anaemia secondary to postpartum...... haemorrhage to RBC transfusion or intravenous iron, and to describe patient-reported outcomes, and haematological and iron parameters. MATERIALS AND METHODS: Women with a postpartum haemorrhage exceeding 1000 ml and an Hb between 5·6 and 8·1 g/dl were randomized to 1500 mg of intravenous iron (n = 7......) isomaltoside or RBC transfusion (n = 6). Participants completed the Multidimensional Fatigue Inventory and Edinburgh Postnatal Depression Scale, and blood samples were drawn at inclusion, daily during the first week and at weeks 3, 8 and 12. RESULTS: We screened 162 women and included 13 (8...

  1. Luminol, horseradish peroxidase, and glucose oxidase ternary functionalized graphene oxide for ultrasensitive glucose sensing.

    Science.gov (United States)

    Li, Fang; Ma, Wenjing; Liu, Jiachang; Wu, Xiang; Wang, Yan; He, Jianbo

    2018-01-01

    Luminol, horseradish peroxidase (HRP), and glucose oxidase (GOx) ternary functionalized graphene oxide (HRP/GOx-luminol-GO) with excellent chemiluminescence (CL) activity and specific enzymatic property was prepared via a simple and general strategy for the first time. In this approach, luminol functionalized GO (luminol-GO) was prepared by gently stirring GO with luminol. Then HRP and GOx were further co-immobilized onto the surface of luminol-GO by storing HRP and GOx with luminol-GO at 4 °C overnight, to form HRP/GOx-luminol-GO bionanocomposites. The synthesized HRP/GOx-luminol-GO could react with H 2 O 2 generated from GOx catalyzed glucose oxidization reaction, to produce strong CL emission in the presence of co-immobilized HRP. Thus, we developed an ultrasensitive, homogeneous, reagentless, selective, and simple CL sensing system for glucose detection. The resulting biosensors exhibited ultra-wide linear range from 5.0 nM to 5.0 mM, and an ultra-low detection limit of 1.2 nM, which was more than 3 orders of magnitude lower than previously reported methods. Furthermore, the sensing system was successfully applied for the detection of glucose in human blood samples.

  2. Challenges and perspectives in continuous glucose monitoring.

    Science.gov (United States)

    van Enter, Benjamin Jasha; von Hauff, Elizabeth

    2018-04-24

    Diabetes is a global epidemic that threatens the health and well-being of hundreds of millions of people. The first step in patient treatment is to monitor glucose levels. Currently this is most commonly done using enzymatic strips. This approach suffers from several limitations, namely it requires a blood sample and is therefore invasive, the quality and the stability of the enzymatic strips vary widely, and the patient is burdened by performing the measurement themselves. This results in dangerous fluctuations in glucose levels often going undetected. There is currently intense research towards new approaches in glucose detection that would enable non-invasive continuous glucose monitoring (CGM). In this review, we explore the state-of-the-art in glucose detection technologies. In particular, we focus on the physical mechanisms behind different approaches, and how these influence and determine the accuracy and reliability of glucose detection. We begin by reviewing the basic physical and chemical properties of the glucose molecule. Although these play a central role in detection, especially the anomeric ratio, they are surprisingly often overlooked in the literature. We then review state-of-the art and emerging detection methods. Finally, we survey the current market for glucometers. Recent results show that past challenges in glucose detection are now being overcome, thereby enabling the development of smart wearable devices for non-invasive continuous glucose monitoring. These new directions in glucose detection have enormous potential to improve the quality of life of millions of diabetics, as well as offer insight into the development, treatment and even prevention of the disease.

  3. Design of Amperometric Biosensors for the Detection of Glucose Prepared by Immobilization of Glucose Oxidase on Conducting (PolyThiophene Films

    Directory of Open Access Journals (Sweden)

    Maria Pilo

    2018-01-01

    Full Text Available Enzyme-based sensors have emerged as important analytical tools with application in diverse fields, and biosensors for the detection of glucose using the enzyme glucose oxidase have been widely investigated. In this work, the preparation of biosensors by electrochemical polymerization of (polythiophenes, namely 2,2′-bithiophene (2,2′-BT and 4,4′-bis(2-methyl-3-butyn-2-ol-2,2′-bithiophene (4,4′-bBT, followed by immobilization of glucose oxidase on the films, is described. N-cyclohexyl-N′-(2-morpholinoethylcarbodiimide metho-p-toluenesulfonate (CMC was used as a condensing agent, and p-benzoquinone (BQ was used as a redox mediator in solution. The glucose oxidase electrodes with films of 2,2′-BT and 4,4′-bBT were then tested for their ability in detecting glucose from synthetic and real samples (pear, apricot, and peach fruit juices.

  4. Timing of hypertonic glucose and thermochemotherapy with 1-(4-amino-2-methylpyrimidine-5-yl) methyl-3-(2-chloroethyl)-3-nitrosourea (ACNU) in the BT4An rat glioma: relation to intratumoral pH reduction and circulatory changes after glucose supply

    International Nuclear Information System (INIS)

    Schem, Baard-Christian; Roszinski, Stefan; Krossnes, Baard Kronen; Mella, Olav

    1995-01-01

    Purpose: Intraperitoneal hypertonic glucose has previously been shown to induce hyperglycemia, hemoconcentration, and to influence systemic and tumor circulation, and, thus, enhance the effect of thermochemotherapy with 1-(4-amino-2-methylpyrimidine-5-yl)methyl-3-(2-chloroethyl)-3-nitrosourea (ACNU) and 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU). However, the optimal timing and the precise mechanisms responsible are not known. The effect of different time intervals between glucose load and thermochemotherapy with ACNU in the treatment of BT 4 An tumors, therefore, was investigated. Changes of serum glucose (Se-glucose), hemoglobin, systemic circulation parameters, tumor pH, and tumor temperature, induced by intraperitoneal glucose and/or hyperthermia, were measured to assess their effect on tumor growth. Methods and Materials: (a): Inbred BD IX rats with BT 4 An tumors on the hind leg were treated with ACNU 7 mg/kg intravenously just before waterbath hyperthermia, and intraperitoneal hypertonic glucose (6 g/kg) at different time intervals before (240-0 min) or immediately after thermochemotherapy. (b): Intratumoral pH and temperature were measured at different intervals after intraperitoneal glucose, and during hyperthermia with or without previous glucose. (c): Hemoglobin, hematocrit, and Se-glucose were measured at different times after intraperitoneal glucose. (d): Mean arterial pressure, pulse pressure, and heart rate were measured for 120 min after intraperitoneal glucose. Results: (a): The number of tumor controls and the growth delay was greatest with glucose 45 min before thermochemotherapy, and least with a time interval of 240 min. Glucose after thermochemotherapy delayed tumor growth. (b): After intraperitoneal glucose alone, intratumoral pH decreased gradually from 6.76 to 5.86 after 240 min. Hyperthermia 120 min after glucose induced a rapid further pH drop, while hyperthermia alone had no significant influence on pH. Intratumoral temperature was

  5. Validity of a portable glucose, total cholesterol, and triglycerides multi-analyzer in adults.

    Science.gov (United States)

    Coqueiro, Raildo da Silva; Santos, Mateus Carmo; Neto, João de Souza Leal; Queiroz, Bruno Morbeck de; Brügger, Nelson Augusto Jardim; Barbosa, Aline Rodrigues

    2014-07-01

    This study investigated the accuracy and precision of the Accutrend Plus system to determine blood glucose, total cholesterol, and plasma triglycerides in adults and evaluated its efficiency in measuring these blood variables. The sample consisted of 53 subjects (≥ 18 years). For blood variable laboratory determination, venous blood samples were collected and processed in a Labmax 240 analyzer. To measure blood variables with the Accutrend Plus system, samples of capillary blood were collected. In the analysis, the following tests were included: Wilcoxon and Student's t-tests for paired samples, Lin's concordance coefficient, Bland-Altman method, receiver operating characteristic curve, McNemar test, and k statistics. The results show that the Accutrend Plus system provided significantly higher values (p ≤ .05) of glucose and triglycerides but not of total cholesterol (p > .05) as compared to the values determined in the laboratory. However, the system showed good reproducibility (Lin's coefficient: glucose = .958, triglycerides = .992, total cholesterol = .940) and high concordance with the laboratory method (Lin's coefficient: glucose = .952, triglycerides = .990, total cholesterol = .944) and high sensitivity (glucose = 80.0%, triglycerides = 90.5%, total cholesterol = 84.4%) and specificity (glucose = 100.0%, triglycerides = 96.9%, total cholesterol = 95.2%) in the discrimination of high values of the three blood variables analyzed. It could be concluded that despite the tendency to overestimate glucose and triglyceride levels, a portable multi-analyzer is a valid alternative for the monitoring of metabolic disorders and cardiovascular risk factors. © The Author(s) 2013.

  6. The prevalence of diabetes mellitus and impaired glucose tolerance ...

    African Journals Online (AJOL)

    The prevalence of diabetes mellitus and impaired glucose tolerance (IGT) was determined in 479 urbanised South African blacks (141 men and 338 women) of Zulu descent selected by cluster sampling in a suburb of Durban. All subjects underwent a modified glucose tolerance test whereby fasting and 2-hour postglucose ...

  7. Interference studies with two hospital-grade and two home-grade glucose meters.

    Science.gov (United States)

    Lyon, Martha E; Baskin, Leland B; Braakman, Sandy; Presti, Steven; Dubois, Jeffrey; Shirey, Terry

    2009-10-01

    Interference studies of four glucose meters (Nova Biomedical [Waltham, MA] StatStrip [hospital grade], Roche Diagnostics [Indianapolis, IN] Accu-Chek Aviva [home grade], Abbott Diabetes Care [Alameda, CA] Precision FreeStyle Freedom [home grade], and LifeScan [Milpitas, CA] SureStep Flexx [hospital grade]) were evaluated and compared to the clinical laboratory plasma hexokinase reference method (Roche Hitachi 912 chemistry analyzer). These meters were chosen to reflect the continuum of care from hospital to home grade meters commonly seen in North America. Within-run precision was determined using a freshly prepared whole blood sample spiked with concentrated glucose to give three glucose concentrations. Day-to-day precision was evaluated using aqueous control materials supplied by each vendor. Common interferences, including hematocrit, maltose, and ascorbate, were tested alone and in combination with one another on each of the four glucose testing devices at three blood glucose concentrations. Within-run precision for all glucose meters was glucose meters. Ascorbate caused differences (percentage change from a sample without added interfering substances) of >5% with pyrroloquinolinequinone (PQQ)-glucose dehydrogenase-based technologies (Aviva and Freestyle) and the glucose oxidase-based Flexx meter. Maltose strongly affected the PQQ-glucose dehydrogenase-based meter systems. When combinations of interferences (ascorbate, maltose, and hematocrit mixtures) were tested, the extent of the interference was up to 193% (Aviva), 179% (FreeStyle), 25.1% (Flexx), and 5.9% (StatStrip). The interference was most pronounced at low glucose (3.9-4.4 mmol/L). All evaluated glucose meter systems demonstrated varying degrees of interference by hematocrit, ascorbate, and maltose mixtures. PQQ-glucose dehydrogenase-based technologies showed greater susceptibility than glucose oxidase-based systems. However, the modified glucose oxidase-based amperometric method (Nova StatStrip) was

  8. Analytical model for real time, noninvasive estimation of blood glucose level.

    Science.gov (United States)

    Adhyapak, Anoop; Sidley, Matthew; Venkataraman, Jayanti

    2014-01-01

    The paper presents an analytical model to estimate blood glucose level from measurements made non-invasively and in real time by an antenna strapped to a patient's wrist. Some promising success has been shown by the RIT ETA Lab research group that an antenna's resonant frequency can track, in real time, changes in glucose concentration. Based on an in-vitro study of blood samples of diabetic patients, the paper presents a modified Cole-Cole model that incorporates a factor to represent the change in glucose level. A calibration technique using the input impedance technique is discussed and the results show a good estimation as compared to the glucose meter readings. An alternate calibration methodology has been developed that is based on the shift in the antenna resonant frequency using an equivalent circuit model containing a shunt capacitor to represent the shift in resonant frequency with changing glucose levels. Work under progress is the optimization of the technique with a larger sample of patients.

  9. Preliminary Study of Intravenous Amantadine Treatment for Ataxia Management in Patients with Probable Multiple System Atrophy with Predominant Cerebellar Ataxia

    Directory of Open Access Journals (Sweden)

    Jinyoung Youn

    2012-05-01

    Full Text Available Background and Purpose: Multiple system atrophy with predominant cerebellar ataxia is a disabling neurologic disease. However, effective management has not yet been established. We conducted a short-term, open-label preliminary study to assess the benefits of intravenous amantadine treatment in patients with probable multiple system atrophy with predominant cerebellar ataxia. Methods: Twenty patients (10 male, 10 female with probable multiple system atrophy with predominant cerebellar ataxia received 400 mg of amantadine by intravenous per day for 5 days. Ataxia severity was evaluated by the International Cooperative Ataxia Rating Scale before and after intravenous amantadine therapy and all subjects reported subjective improvement after intravenous amantadine treatment using a patient global impression scale. We analyzed the total and subscale scores by the ataxia scale and patient global impression scale. Results: The mean age was 57.4 years (range: 47–72 and the mean disease duration was 30.8 months (range: 11–79. The ataxia severity significantly decreased after intravenous amantadine therapy from 42.5 to 37.3 (p < 0.001. The mean patient global impression scale for improvement was 2.9 and there were no side effects of intravenous amantadine treatment observed. When we assessed responders, the duration of intravenous amantadine effect was more than 1 month in 4 subjects of 7 responders. Conclusions: Our findings suggest that intravenous amantadine treatment can be a safe management option in cerebellar ataxia, although the mechanism is unclear. Thus, further double-blind, long-term studies with a larger sample size are needed.

  10. An acute rat in vivo screening model to predict compounds that alter blood glucose and/or insulin regulation.

    Science.gov (United States)

    Brott, David A; Diamond, Melody; Campbell, Pam; Zuvich, Andy; Cheatham, Letitia; Bentley, Patricia; Gorko, Mary Ann; Fikes, James; Saye, JoAnne

    2013-01-01

    Drug-induced glucose dysregulation and insulin resistance have been associated with weight gain and potential induction and/or exacerbation of diabetes mellitus in the clinic suggesting they may be safety biomarkers when developing antipsychotics. Glucose and insulin have also been suggested as potential efficacy biomarkers for some oncology compounds. The objective of this study was to qualify a medium throughput rat in vivo acute Intravenous Glucose Tolerance Test (IVGTT) for predicting compounds that will induce altered blood glucose and/or insulin levels. Acute and sub-chronic studies were performed to qualify an acute IVGTT model. Double cannulated male rats (Han-Wistar and Sprague-Dawley) were administered vehicle, olanzapine, aripiprazole or other compounds at t=-44min for acute studies and at time=-44min on the last day of dosing for sub-chronic studies, treated with dextrose (time=0min; i.v.) and blood collected using an automated Culex® system for glucose and insulin analysis (time=-45, -1, 2, 10, 15, 30, 45, 60, 75, 90, 120, 150 and 180min). Olanzapine significantly increased glucose and insulin area under the curve (AUC) values while aripiprazole AUC values were similar to control, in both acute and sub-chronic studies. All atypical antipsychotics evaluated were consistent with literature references of clinical weight gain. As efficacy biomarkers, insulin AUC but not glucose AUC values were increased with a compound known to have insulin growth factor-1 (IGF-1) activity, compared to control treatment. These studies qualified the medium throughput acute IVGTT model to more quickly screen compounds for 1) safety - the potential to elicit glucose dysregulation and/or insulin resistance and 2) efficacy - as a surrogate for compounds affecting the glucose and/or insulin regulatory pathways. These data demonstrate that the same in vivo rat model and assays can be used to predict both clinical safety and efficacy of compounds. © 2013.

  11. The Interplay between Fasting Glucose, Echocardiography, and Biomarkers

    DEFF Research Database (Denmark)

    Pareek, Manan

    preventive setting, remains incomplete. Phenotypical heterogeneity may be even greater among subjects with hyperglycemic conditions, i.e., prediabetes and diabetes, which is worrisome, given the dramatic global rise in mean fasting glucose levels, and the strong association with adverse cardiovascular...... subclinical changes to manifest disease include echocardiography and circulating biomarkers. Objectives 1) To examine whether greater fasting plasma glucose (FPG) levels were associated with left ventricular mass (LVM), geometric pattern, diastolic function, and concentrations of N-terminal prohormone...... from the three categories defined by baseline FPG, i.e., normal fasting glucose, impaired fasting glucose, and diabetes, including use of anti-diabetic medication. Blood samples for cardiovascular biomarker assessments were drawn at the time of echocardiography and kept frozen until analysis. Outcome...

  12. Statistical transformation and the interpretation of inpatient glucose control data.

    Science.gov (United States)

    Saulnier, George E; Castro, Janna C; Cook, Curtiss B

    2014-03-01

    To introduce a statistical method of assessing hospital-based non-intensive care unit (non-ICU) inpatient glucose control. Point-of-care blood glucose (POC-BG) data from hospital non-ICUs were extracted for January 1 through December 31, 2011. Glucose data distribution was examined before and after Box-Cox transformations and compared to normality. Different subsets of data were used to establish upper and lower control limits, and exponentially weighted moving average (EWMA) control charts were constructed from June, July, and October data as examples to determine if out-of-control events were identified differently in nontransformed versus transformed data. A total of 36,381 POC-BG values were analyzed. In all 3 monthly test samples, glucose distributions in nontransformed data were skewed but approached a normal distribution once transformed. Interpretation of out-of-control events from EWMA control chart analyses also revealed differences. In the June test data, an out-of-control process was identified at sample 53 with nontransformed data, whereas the transformed data remained in control for the duration of the observed period. Analysis of July data demonstrated an out-of-control process sooner in the transformed (sample 55) than nontransformed (sample 111) data, whereas for October, transformed data remained in control longer than nontransformed data. Statistical transformations increase the normal behavior of inpatient non-ICU glycemic data sets. The decision to transform glucose data could influence the interpretation and conclusions about the status of inpatient glycemic control. Further study is required to determine whether transformed versus nontransformed data influence clinical decisions or evaluation of interventions.

  13. The validation of the Z-Scan technique for the determination of plasma glucose

    Science.gov (United States)

    Alves, Sarah I.; Silva, Elaine A. O.; Costa, Simone S.; Sonego, Denise R. N.; Hallack, Maira L.; Coppini, Ornela L.; Rowies, Fernanda; Azzalis, Ligia A.; Junqueira, Virginia B. C.; Pereira, Edimar C.; Rocha, Katya C.; Fonseca, Fernando L. A.

    2013-11-01

    Glucose is the main energy source for the human body. The concentration of blood glucose is regulated by several hormones including both antagonists: insulin and glucagon. The quantification of glucose in the blood is used for diagnosing metabolic disorders of carbohydrates, such as diabetes, idiopathic hypoglycemia and pancreatic diseases. Currently, the methodology used for this determination is the enzymatic colorimetric with spectrophotometric. This study aimed to validate the use of measurements of nonlinear optical properties of plasma glucose via the Z-Scan technique. For this we used samples of calibrator patterns that simulate commercial samples of patients (ELITech ©). Besides calibrators, serum glucose levels within acceptable reference values (normal control serum - Brazilian Society of Clinical Pathology and Laboratory Medicine) and also overestimated (pathological control serum - Brazilian Society of Clinical Pathology and Laboratory Medicine) were used in the methodology proposal. Calibrator dilutions were performed and determined by the Z-Scan technique for the preparation of calibration curve. In conclusion, Z-Scan method can be used to determinate glucose levels in biological samples with enzymatic colorimetric reaction and also to apply the same quality control parameters used in biochemistry clinical.

  14. Increased Incretin But Not Insulin Response after Oral versus Intravenous Branched Chain Amino Acids.

    Science.gov (United States)

    Gojda, Jan; Straková, Radka; Plíhalová, Andrea; Tůma, Petr; Potočková, Jana; Polák, Jan; Anděl, Michal

    2017-01-01

    Branched chain amino acids (BCAAs) are known to exert an insulinotropic effect. Whether this effect is mediated by incretins (glucagon like peptide 1 [GLP-1] or glucose-dependent insulinotropic peptide [GIP]) is not known. The aim of this study was to show whether an equivalent dose of BCAA elicits a greater insulin and incretin response when administered orally than intravenously (IV). Eighteen healthy, male subjects participated in 3 tests: IV application of BCAA solution, oral ingestion of BCAA and placebo in an equivalent dose (30.7 ± 1.1 g). Glucose, insulin, C-peptide, glucagon, GLP-1, GIP, valine, leucine and isoleucine concentrations were measured. Rise in serum BCAA was achieved in both BCAA tests, with incremental areas under the curve (iAUC) being 2.1 times greater for IV BCAA compared with those of the oral BCAA test (p BCAA induced comparable insulin response greater than placebo (240 min insulin iAUC: oral 3,411 ± 577 vs. IV 2,361 ± 384 vs. placebo 961.2 ± 175 pmol/L, p = 0.0006). Oral BCAA induced higher GLP-1 (p BCAA tests with no change in the placebo group. An equivalent dose of BCAA elicited a comparable insulin and greater incretin response when administered orally and not when administered through IV. We conclude that insulinotropic effects of BCAA are partially incretin dependent. © 2017 S. Karger AG, Basel.

  15. Evaluation of Blood Glucose Meter Efficacy in an Antenatal Diabetes Clinic.

    Science.gov (United States)

    McGrath, Rachel T; Donnelly, Vanessa C; Glastras, Sarah J; Preda, Veronica A; Sheriff, Nisa; Ward, Peter; Hocking, Samantha L; Fulcher, Gregory R

    2016-02-01

    The optimal treatment of diabetes in pregnancy requires accurate measurement of blood glucose levels, in order to minimize adverse outcomes for both mother and neonate. Self-monitoring of blood glucose is routinely used to measure glycemic control and to assess whether treatment targets are being met; however, the accuracy of blood glucose meters in pregnancy is unclear. Pregnant women with gestational, type 1, or type 2 diabetes mellitus were eligible to participate. Nonfasting capillary blood glucose levels were measured in duplicate using the BGStar(®) (Sanofi, Sydney, Australia) and FreeStyle Lite(®) (Abbott, Sydney) blood glucose meters. Venous blood samples were collected and analyzed for plasma glucose, hematocrit, and glycated hemoglobin. Capillary blood glucose was compared with plasma glucose and further assessed according to International Organization for Standardization (ISO) 15197:2013 standards. One hundred ten women were recruited, providing 96 samples suitable for analysis. The mean ± SD laboratory plasma glucose level was 4.6 ± 1.4 mmol/L; the BGStar and FreeStyle Lite capillary blood glucose values were 5.3 ± 1.4 mmol/L and 5.0 ± 1.3 mmol/L, respectively. Both meters showed a positive bias (0.42 mmol/L for the FreeStyle Lite and 0.65 mmol/L for the BGStar). Furthermore, neither meter fulfilled the ISO 15197:2013 standards, and there was a nonsignificant improvement in meter performance at blood glucose levels of ≤4.2 mmol/L. Hematocrit did not affect the results of either blood glucose meter. Clarke Error Grid analysis demonstrated that approximately 70% of the results of both meters would lead to appropriate clinical action. The BGStar and FreeStyle Lite blood glucose meters did not meet ISO 15197:2013 recommendations for blood glucose monitoring systems when assessed in a population of women with diabetes in pregnancy. Clinicians should consider this difference in blood glucose readings when making diabetes

  16. Advances in the use of intravenous techniques in ambulatory anesthesia

    Directory of Open Access Journals (Sweden)

    Eng MR

    2015-07-01

    Full Text Available Matthew R Eng,1 Paul F White1,2 1Department of Anesthesiology, Cedars-Sinai Medical Center, Los Angeles, CA, USA; 2White Mountain Institute, The Sea Ranch, CA, USA Summary statement: Advances in the use of intravenous techniques in ambulatory anesthesia has become important for the anesthesiologist as the key perioperative physician in outpatient surgery. Key techniques and choices of anesthetics are important in accomplishing fast track goals of ambulatory surgery. Purpose of review: The anesthesiologist in the outpatient environment must focus on improving perioperative efficiency and reducing recovery times while accounting for patients' well-being and safety. This review article focuses on recent intravenous anesthetic techniques to accomplish these goals. Recent findings: This review is an overview of techniques in intravenous anesthesia for ambulatory anesthesia. Intravenous techniques may be tailored to accomplish outpatient surgery goals for the type of surgical procedure and individual patient needs. Careful anesthetic planning and the application of the plans are critical to an anesthesiologist's success with fast-track ambulatory surgery. Conclusion: Careful planning and application of intravenous techniques are critical to an anesthesiologist's success with fast-track ambulatory surgery. Keywords: intravenous anesthesia, outpatient anesthesia, fast-track surgery

  17. Comparison of blood glucose test strips in the detection of neonatal hypoglycaemia

    OpenAIRE

    Wilkins, B H; Kalra, D

    1982-01-01

    Blood glucose levels were estimated in 101 neonatal blood samples using three glucose test strip methods and the results compared with those from a laboratory. BM-test-glycemie 20-800 test strips and Reflotest-hypoglycemie test strips gave a rapid and reliable estimate of blood glucose level in the range 0-8 mmol/l (0-140 mg/100 ml). Dextrostix test strips tended to overestimate all blood glucose levels.

  18. Magnetic Resonance Imaging-DRAGON score: 3-month outcome prediction after intravenous thrombolysis for anterior circulation stroke.

    Science.gov (United States)

    Turc, Guillaume; Apoil, Marion; Naggara, Olivier; Calvet, David; Lamy, Catherine; Tataru, Alina M; Méder, Jean-François; Mas, Jean-Louis; Baron, Jean-Claude; Oppenheim, Catherine; Touzé, Emmanuel

    2013-05-01

    The DRAGON score, which includes clinical and computed tomographic scan parameters, showed a high specificity to predict 3-month outcome in patients with acute ischemic stroke treated by intravenous tissue plasminogen activator. We adapted the score for patients undergoing MRI as the first-line diagnostic tool. We reviewed patients with consecutive anterior circulation ischemic stroke treated ≤ 4.5 hour by intravenous tissue plasminogen activator between 2003 and 2012 in our center, where MRI is systematically implemented as first-line diagnostic work-up. We derived the MRI-DRAGON score keeping all clinical parameters of computed tomography-DRAGON (age, initial National Institutes of Health Stroke Scale and glucose level, prestroke handicap, onset to treatment time), and considering the following radiological variables: proximal middle cerebral artery occlusion on MR angiography instead of hyperdense middle cerebral artery sign, and diffusion-weighted imaging Alberta Stroke Program Early Computed Tomography Score (DWI ASPECTS) ≤ 5 instead of early infarct signs on computed tomography. Poor 3-month outcome was defined as modified Rankin scale >2. We calculated c-statistics as a measure of predictive ability and performed an internal cross-validation. Two hundred twenty-eight patients were included. Poor outcome was observed in 98 (43%) patients and was significantly associated with all parameters of the MRI-DRAGON score in multivariate analysis, except for onset to treatment time (nonsignificant trend). The c-statistic was 0.83 (95% confidence interval, 0.78-0.88) for poor outcome prediction. All patients with a MRI-DRAGON score ≤ 2 (n=22) had a good outcome, whereas all patients with a score ≥ 8 (n=11) had a poor outcome. The MRI-DRAGON score is a simple tool to predict 3-month outcome in acute stroke patients screened by MRI then treated by intravenous tissue plasminogen activator and may help for therapeutic decision.

  19. The intravenous injection of illicit drugs and needle sharing: an historical perspective.

    Science.gov (United States)

    Zule, W A; Vogtsberger, K N; Desmond, D P

    1997-01-01

    This study reviewed the literature on the history of needle sharing and intravenous drug abuse. Reports suggest that needle sharing was practiced by drug abusers as early as 1902 in China and 1914 in the United States. Intravenous drug abuse was first mentioned in the literature in 1925. However other references suggest that some opioid users were injecting intravenously prior to 1920. Outbreaks of malaria in Egypt, the United States, and China between 1929 and 1937 were attributed to needle sharing and intravenous injection of opioids. These reports suggest that both needle sharing and intravenous drug use were common by 1937. Factors such as medical use of intravenous injections, enactment and zealous enforcement of antinarcotic laws, and interactions among drug users in institutional settings such as regional hospitals and prisons may have contributed to the spread of both needle sharing and the intravenous technique among drug abusers.

  20. Efficacy and safety of non-intravenous midazolam for the treatment of status epilepticus in children: a Meta-analysis

    Directory of Open Access Journals (Sweden)

    Yan LIN

    2016-02-01

    Full Text Available Objective To evaluate the clinical efficacy and safety of non-intravenous midazolam for treating status epilepticus (SE in children.  Methods Taking midazolam, status epilepticus and children both in Chinese and English as search terms, retrieve in databases such as PubMed, ScienceDirect, China National Knowledge Infrastructure (CNKI, VIP and Wanfang Data, assisted by manual searching and Google Scholar, in order to collect randomized controlled trials (RCTs about non-intravenous midazolam for treating SE in children from January 2000 to January 2015. Jadad Scale was used to evaluate the quality of literatures. Meta-analysis was performed by using RevMan 5.3 software. Results There were a total of 258 records after preliminary searching, and 6 RCTs involving 766 episodes were finally included after excluding duplicate ones and those which did not meet the inclusion criteria. The results were as follows: 1 midazolam via intranasal administration was as effective as intravenous diazepam in achieving seizure control in children (RD = -0.070, 95%CI: -0.200—0.060, P = 0.290. However, non-intravenous (intranasal or buccal midazolam showed better effects on seizure control than rectal diazepam (RD = 0.170, 95% CI: 0.030—0.320; P = 0.020. 2 The mean time from arrival at hospital to cessation was not significantly different between intranasal midazolam and intravenous diazepam (SMD = -1.570, 95%CI: -3.280—0.140; P = 0.070. 3 There was no statistical difference between intranasal midazolam and intravenous diazepam for the time from giving drug to cessation (SMD = 0.240, 95%CI: -0.110—0.590; P = 0.170. 4 There was no statistical difference on the occurrence rate of adverse drug reactions between non-intravenous midazolam and intravenous or non-intravenous diazepam (RD = -0.010, 95% CI: -0.030—0.200; P = 0.500.  Conclusions Non-intravenous midazolam is safe and effective in the treatment for status epilepticus in children. However, the

  1. Glucose kinetics in gluconeogenesis-inhibited rats during rest and exercise

    International Nuclear Information System (INIS)

    Turcotte, L.P.; Rovner, A.S.; Roark, R.R.; Brooks, G.A.

    1990-01-01

    To evaluate the role played by gluconeogenesis in blood glucose homeostasis, female Sprague-Dawley rats were injected with mercaptopicolinic acid (MPA), a gluconeogenic inhibitor. Glucose kinetics were assessed by primed, continuous infusion of [U-14C]- and [6(-3)H]glucose via an indwelling jugular catheter at rest and during submaximal exercise at 13.4 m/min on level grade. Blood samples were taken from carotid catheters and analyzed for glucose and lactate concentrations and specific activities. Tissue glycogen samples were obtained from rats after exercise as well as from unexercised animals. When compared with the sham-injected animals, MPA-treated animals had 22% lower (5.92 +/- 0.36 vs. 7.62 +/- 0.21 mM) and 44% higher (1.90 +/- 0.11 vs. 1.32 +/- 0.09 mM) resting arterial glucose and lactate concentrations, respectively. Resting glucose appearance (Ra) rates were 20% lower in the MPA-treated animals (57.2 +/- 7.5 mumol.kg-1.min-1) than in the sham-injected animals (71.1 +/- 12.1 mumol.kg-1.min-1). During exercise, Ra increased to 174.7 +/- 32.8 mumol.kg-1.min-1 in sham-injected animals. In the MPA-treated animals, there was a 35% increase during the first 15 min of exercise, followed by a decrease to the resting values. MPA-treated animals had no measurable glucose recycling at rest or during exercise. Exercise decreased blood glucose concentration (35%) and increased blood lactate concentration (160%) in the MPA-treated animals. Exercising sham-injected animals had increased blood glucose (9.8%) but no change in blood lactate concentration. Moderate depletions in liver and skeletal muscle glycogen contents were observed after exercise

  2. Study of potential utility of new radiopharmaceuticals based on technetium-99m labeled derivative of glucose

    Science.gov (United States)

    Zeltchan, R.; Medvedeva, A.; Sinilkin, I.; Chernov, V.; Stasyuk, E.; Rogov, A.; Il'ina, E.; Larionova, L.; Skuridin, V.

    2016-08-01

    Purpose: to study the potential utility of 1-thio-D-glucose labeled with 99mTc for cancer imaging in laboratory animals. Materials and method: the study was carried out in cell cultures of normal CHO (Chinese hamster ovary cells CHO) and malignant tissues MCF-7 (human breast adenocarcinoma MCF-7). To evaluate the uptake of 99mTc-1-thio-D-glucose in normal and tumor tissue cells, 25 MBq of 1-thio-D-glucose labeled with 99mTc was added to the vials with 3 million cells and incubated for 30 min at room temperature. After centrifugation of the vials with cells, the supernatant was removed. The radioactivity in vials with normal and tumor cells was then measured. In addition, the study included 40 mice of C57B1/6j lines with tumor lesion of the right femur. For neoplastic lesions, Lewis lung carcinoma model was used. Following anesthesia, mice were injected intravenously with 25 MBq of 99mTc-1-thio-D-glucose. Planar scintigraphy was performed 15 minutes later in a matrix of 512x512 pixels for 5 min. Results: when measuring the radioactivity of normal and malignant cells after incubation with 99mTc-1-thio-D-glucose, it was found that the radioactivity of malignant cells was higher than that of normal cells. The mean values of radioactivity levels in normal and malignant cells were 0.3 ± 0.15 MBq and 1.07 ± 0.6 MBq, respectively. All examined animals had increased accumulation of 99mTc-1-thio-D-glucose at the tumor site. The accumulation of 99mTc-1-thio-D-glucose in the tumor was on average twice as high as compared to the symmetric region. Conclusion: The present study demonstrated that 99mTc-1-thio-D-glucose is a prospective radiopharmaceutical for cancer visualization. In addition, high accumulation of 99mTc-1-thio-D-glucose in the culture of cancer cells and in tumor tissue of animals demonstrates tumor tropism of the radiopharmaceutical.

  3. Experimental study of radiopharmaceuticals based on technetium-99m labeled derivative of glucose for tumor diagnosis

    Science.gov (United States)

    Zeltchan, R.; Medvedeva, A.; Sinilkin, I.; Bragina, O.; Chernov, V.; Stasyuk, E.; Rogov, A.; Il'ina, E.; Larionova, L.; Skuridin, V.; Dergilev, A.

    2016-06-01

    Purpose: to study the potential utility of 1-thio-D-glucose labeled with 99mTc for cancer imaging in laboratory animals. Materials and method: the study was carried out in cell cultures of normal CHO (Chinese hamster ovary cells CHO) and malignant tissues MCF-7 (human breast adenocarcinoma MCF-7). To evaluate the uptake of 99mTc-1-thio-D-glucose in normal and tumor tissue cells, 25 MBq of 1-thio-D-glucose labeled with 99mTc was added to the vials with 3 million cells and incubated for 30 minutes at room temperature. After centrifugation of the vials with cells, the supernatant was removed. Radioactivity in vials with normal and tumor cells was then measured. In addition, the study included 40 mice of C57B 1/6j lines with tumor lesion of the right femur. For neoplastic lesions, Lewis lung carcinoma model was used. Following anesthesia, mice were injected intravenously with 25MBq of 99mTc-1-thio-D-glucose. Planar scintigraphy was performed 15 minutes later in a matrix of 512x512 pixels for 5 minutes. Results: when measuring the radioactivity of normal and malignant cells after incubation with 99mTc-1-thio-D- glucose, it was found that the radioactivity of malignant cells was higher than that of normal cells. The mean values of radioactivity levels in normal and malignant cells were 0.3±0.15MBq and 1.07±0.6MBq, respectively. All examined animals had increased accumulation of 99mTc-1-thio- D-glucose at the tumor site. The accumulation of 99mTc-1-thio-D-glucose in the tumor was on average twice as high as compared to the symmetric region. Conclusion: The present study demonstrated that 99mTc-1-thio-D-glucose is a prospective radiopharmaceutical for cancer visualization. In addition, high accumulation of 99mTc-1-thio-D-glucose in the culture of cancer cells and in tumor tissue of animals demonstrates tumor tropism of the radiopharmaceutical.

  4. First step toward near-infrared continuous glucose monitoring: in vivo evaluation of antibody coupled biomaterials

    Science.gov (United States)

    Gellynck, Karolien; Kodeck, Valérie; Van De Walle, Elke; Kersemans, Ken; De Vos, Filip; Declercq, Heidi; Dubruel, Peter; Vlaminck, Lieven

    2015-01-01

    Continuous glucose monitoring (CGM) is crucial in diabetic care. Long-term CGM systems however require an accurate sensor as well as a suitable measuring environment. Since large intravenous sensors are not feasible, measuring inside the interstitial fluid is considered the best alternative. This option, unfortunately, has the drawback of a lag time with blood glucose values. A good strategy to circumvent this is to enhance tissue integration and enrich the peri-implant vasculature. Implants of different optically transparent biomaterials (poly(methyl-methacrylate) [PMMA] and poly(dimethylsiloxane) [PDMS]) – enabling glucose monitoring in the near-infrared (NIR) spectrum – were surface-treated and subsequently implanted in goats at various implantation sites for up to 3 months. The overall in vivo biocompatibility, tissue integration, and vascularization at close proximity of the surfaces of these materials were assessed. Histological screening showed similar tissue reactions independent of the implantation site. No significant inflammation reaction was observed. Tissue integration and vascularization correlated, to some extent, with the biomaterial composition. A modification strategy, in which a vascular endothelial-cadherin antibody was coupled to the biomaterials surface through a dopamine layer, showed significantly enhanced vascularization 3 months after subcutaneous implantation. Our results suggest that the developed strategy enables the creation of tissue interactive NIR transparent packaging materials, opening the possibility of continuous glucose monitoring. PMID:25304314

  5. Continuous glucose monitoring, oral glucose tolerance, and insulin - glucose parameters in adolescents with simple obesity.

    Science.gov (United States)

    El Awwa, A; Soliman, A; Al-Ali, M; Yassin, M; De Sanctis, V

    2012-09-01

    In obese adolescents pancreatic beta-cells may not be able to cope with insulin resistance leading to hyperglycemia and type2 diabetes (T2DM To assess oral glucose tolerance, 72-h continuous blood glucose concentrations (CGM) and calculate homeostatic model assessment (HOMA), and the quantitative insulin sensitivity check index (QUICKI) in 13 adolescents with simple obesity (BMI SDS=4 ± 1.06). OGTT performed in 13 obese adolescents (13.47 ± 3 years) revealed 3 cases (23%) with impaired fasting glucose (IFG: fasting glucose >5.6 mmol/L), 4 cases (30%) with impaired glucose tolerance (IGT: 2h blood glucose >7.8 continuous glucose monitoring system ( CGMS), IFG was detected in 4 cases, the maximum serum blood glucose (BG : 2h or more after meal) was >7.8 and 11.1 mmol/L (diabetes) in one case (7.6%). Five cases had a minimum BG recorded of 2.6 and QUICKI values obese adolescents, CGMS is superior to OGTT and HbA1C in detecting glycemic abnormalities, which appears to be secondary to insulin resistance.

  6. Insulin delivery route for the artificial pancreas: subcutaneous, intraperitoneal, or intravenous? Pros and cons.

    Science.gov (United States)

    Renard, Eric

    2008-07-01

    Insulin delivery is a crucial component of a closed-loop system aiming at the development of an artificial pancreas. The intravenous route, which has been used in the bedside artificial pancreas model for 30 years, has clear advantages in terms of pharmacokinetics and pharmacodynamics, but cannot be used in any ambulatory system so far. Subcutaneous (SC) insulin infusion benefits from the broad expansion of insulin pump therapy that promoted the availability of constantly improving technology and fast-acting insulin analog use. However, persistent delays of insulin absorption and action, variability and shortterm stability of insulin infusion from SC-inserted catheters generate effectiveness and safety issues in view of an ambulatory, automated, glucose-controlled, artificial beta cell. Intraperitoneal insulin delivery, although still marginally used in diabetes care, may offer an interesting alternative because of its more-physiological plasma insulin profiles and sustained stability and reliability of insulin delivery.

  7. A Robust, Enzyme-Free Glucose Sensor Based on Lysine-Assisted CuO Nanostructures

    Directory of Open Access Journals (Sweden)

    Qurrat-ul-Ain Baloach

    2016-11-01

    Full Text Available The production of a nanomaterial with enhanced and desirable electrocatalytic properties is of prime importance, and the commercialization of devices containing these materials is a challenging task. In this study, unique cupric oxide (CuO nanostructures were synthesized using lysine as a soft template for the evolution of morphology via a rapid and boiled hydrothermal method. The morphology and structure of the synthesized CuO nanomaterial were characterized using scanning electron microscopy (SEM and X-ray diffraction (XRD, respectively. The prepared CuO nanostructures showed high potential for use in the electrocatalytic oxidation of glucose in an alkaline medium. The proposed enzyme-free glucose sensor demonstrated a robust response to glucose with a wide linear range and high sensitivity, selectivity, stability, and reproducibility. To explore its practical feasibility, the glucose content of serum samples was successfully determined using the enzyme-free sensor. An analytical recovery method was used to measure the actual glucose from the serum samples, and the results were satisfactory. Moreover, the presented glucose sensor has high chemical stability and can be reused for repetitive measurements. This study introduces an enzyme-free glucose sensor as an alternative tool for clinical glucose quantification.

  8. Diagnostic utility of intravenous contrast for MR imaging in pediatric appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Lyons, Gray R.; Renjen, Pooja; Kovanlikaya, Arzu [New York-Presbyterian Hospital/Weill Cornell Medicine, Department of Radiology, New York, NY (United States); Askin, Gulce; Giambrone, Ashley E. [New York-Presbyterian Hospital/Weill Cornell Medicine, Department of Biostatistics and Epidemiology, New York, NY (United States); Beneck, Debra [New York-Presbyterian Hospital/Weill Cornell Medicine, Department of Pathology, New York, NY (United States)

    2017-04-15

    Magnetic resonance imaging (MRI) is increasingly employed as a diagnostic modality for suspected appendicitis in children. However, there is uncertainty as to which MRI sequences are sufficient for safe, timely and accurate diagnosis. Several recent studies have described different MRI protocols, including exams both with and without the use of intravenous contrast. We hypothesized that intravenous contrast may be useful in some patients but could be safely omitted in others. All MRI examinations (n=112) performed at our institution for evaluating appendicitis in children were retrospectively reevaluated. Exams were reread by pediatric radiologists under three conditions: With postcontrast images, Without postcontrast images, and Without/With - selective use of postcontrast sequences only when needed for diagnostic certainty. Samples were scored as positive, negative or equivocal for appendicitis. Findings were compared to pathological or clinical follow-up in the medical record. Without the use of intravenous contrast yielded more equivocal results (12.4%) compared to With contrast (3.4%). By selectively using postcontrast sequences, the Without/With group yielded fewer equivocal results (1.1%) compared to Without while also reducing contrast use 79.8% compared to the With contrast group. No significant differences in conditional sensitivity or conditional specificity were detected among the three groups. MRI diagnosis of acute appendicitis can be performed without contrast for most patients; injection of contrast can be reserved for only those patients with equivocal non-contrast imaging. (orig.)

  9. Brain metabolism is significantly impaired at blood glucose below 6 mM and brain glucose below 1 mM in patients with severe traumatic brain injury

    OpenAIRE

    Meierhans, Roman; B?chir, Markus; Ludwig, Silke; Sommerfeld, Jutta; Brandi, Giovanna; Haberth?r, Christoph; Stocker, Reto; Stover, John F

    2010-01-01

    Introduction The optimal blood glucose target following severe traumatic brain injury (TBI) must be defined. Cerebral microdialysis was used to investigate the influence of arterial blood and brain glucose on cerebral glucose, lactate, pyruvate, glutamate, and calculated indices of downstream metabolism. Methods In twenty TBI patients, microdialysis catheters inserted in the edematous frontal lobe were dialyzed at 1 ?l/min, collecting samples at 60 minute intervals. Occult metabolic alteratio...

  10. Brain metabolism is significantly impaired at blood glucose below 6 mM and brain glucose beneath 1 mM in patients with severe traumatic brain injury.

    OpenAIRE

    Meierhans, R; Bechir, M; Ludwig, S; Sommerfeld, J; Brandi, G; Haberthur, C; Stocker, R; Stover, J F

    2010-01-01

    ABSTRACT: INTRODUCTION: The optimal blood glucose target following severe traumatic brain injury (TBI) must be defined. Cerebral microdialysis was used to investigate the influence of arterial blood and brain glucose on cerebral glucose, lactate, pyruvate, glutamate, and calculated indices of downstream metabolism. METHODS: In twenty TBI patients, microdialysis catheters inserted in the edematous frontal lobe were dialyzed at 1 mul/ min, collecting samples at 60 minute intervals. Occult metab...

  11. Photoacoustic determination of glucose concentration in whole blood by a near-infrared laser diode

    Science.gov (United States)

    Zhao, Zuomin; Myllylae, Risto A.

    2001-06-01

    The near-infrared photoacoustic technique is recognized as a potential method for the non-invasive determination of human glucose, because near-infrared light can incident a few millimeters into human tissue, where it produces an acoustic wave capable of carrying information about the composition of the tissue. This paper demonstrates a photoacoustic glucose measurement in a blood sample as a step toward a non-invasive measurement. The experimental apparatus consists of a near-infrared laser diode operating with 4 micro joules pulse energy at 905 nm, a roller pump connected to a silicon plastic tube and a cuvette for circulating the blood sample. In addition, the apparatus comprises a PZT piezoelectric transducer integrated with a battery-powered preamplifier to receive the photoacoustic signal. During the experiment, a glucose solution is mixed into a human blood sample to change its concentration. Although the absorption coefficient of glucose is much smaller than that of blood in the near-infrared region, the osmotic and hydrophilic properties of glucose decrease the reduced scattering coefficient of blood caused by the dissolved glucose surrounding the blood cells. This changes the distribution of the absorbed optical energy in blood, which, in turn, produces a change in the photoacoustic signal. Our experiment demonstrates that signal amplitudes in fresh and stored blood samples in crease about 7% and 10%, respectively, when the glucose concentration reaches the upper limit of the physiological region (500 mg/dl).

  12. Amperometric glucose biosensor based on glucose oxidase dispersed in multiwalled carbon nanotubes/graphene oxide hybrid biocomposite

    International Nuclear Information System (INIS)

    Palanisamy, Selvakumar; Cheemalapati, Srikanth; Chen, Shen-Ming

    2014-01-01

    An amperometric glucose biosensor based on enhanced and fast direct electron transfer (DET) of glucose oxidase (GOx) at enzyme dispersed multiwalled carbon nanotubes/graphene oxide (MWCNT/GO) hybrid biocomposite was developed. The fabricated hybrid biocomposite was characterized by transmission electron microscopy (TEM), Raman and infrared spectroscopy (IR). The TEM image of hybrid biocomposite reveals that a thin layer of GOx was covered on the surface of MWCNT/GO hybrid composite. IR results validate that the hybrid biocomposite was formed through the electrostatic interactions between GOx and MWCNT/GO hybrid composite. Further, MWCNT/GO hybrid composite has also been characterized by TEM and UV–visible spectroscopy. A pair of well-defined redox peak was observed for GOx immobilized at the hybrid biocomposite electrode than that immobilized at the MWCNT modified electrode. The electron transfer rate constant (K s ) of GOx at the hybrid biocomposite was calculated to be 11.22 s −1 . The higher K s value revealed that fast DET of GOx occurred at the electrode surface. Moreover, fabricated biosensor showed a good sensitivity towards glucose oxidation over a linear range 0.05–23.2 mM. The limit of detection (LOD) was estimated to be 28 μM. The good features of the proposed biosensor could be used for the accurate detection of glucose in the biological samples. - Highlights: • An amperometric glucose biosensor has been developed at MWCNT/GO hybrid biocomposite. • Enhanced and fast direct electron transfer kinetics of glucose oxidase has been achieved at hybrid biocomposite. • Hybrid biocomposite has been characterized by TEM, IR and Raman spectroscopy. • Highly sensitive and selective for glucose determination

  13. Amperometric glucose biosensor based on glucose oxidase dispersed in multiwalled carbon nanotubes/graphene oxide hybrid biocomposite

    Energy Technology Data Exchange (ETDEWEB)

    Palanisamy, Selvakumar; Cheemalapati, Srikanth; Chen, Shen-Ming, E-mail: smchen78@ms15.hinet.net

    2014-01-01

    An amperometric glucose biosensor based on enhanced and fast direct electron transfer (DET) of glucose oxidase (GOx) at enzyme dispersed multiwalled carbon nanotubes/graphene oxide (MWCNT/GO) hybrid biocomposite was developed. The fabricated hybrid biocomposite was characterized by transmission electron microscopy (TEM), Raman and infrared spectroscopy (IR). The TEM image of hybrid biocomposite reveals that a thin layer of GOx was covered on the surface of MWCNT/GO hybrid composite. IR results validate that the hybrid biocomposite was formed through the electrostatic interactions between GOx and MWCNT/GO hybrid composite. Further, MWCNT/GO hybrid composite has also been characterized by TEM and UV–visible spectroscopy. A pair of well-defined redox peak was observed for GOx immobilized at the hybrid biocomposite electrode than that immobilized at the MWCNT modified electrode. The electron transfer rate constant (K{sub s}) of GOx at the hybrid biocomposite was calculated to be 11.22 s{sup −1}. The higher K{sub s} value revealed that fast DET of GOx occurred at the electrode surface. Moreover, fabricated biosensor showed a good sensitivity towards glucose oxidation over a linear range 0.05–23.2 mM. The limit of detection (LOD) was estimated to be 28 μM. The good features of the proposed biosensor could be used for the accurate detection of glucose in the biological samples. - Highlights: • An amperometric glucose biosensor has been developed at MWCNT/GO hybrid biocomposite. • Enhanced and fast direct electron transfer kinetics of glucose oxidase has been achieved at hybrid biocomposite. • Hybrid biocomposite has been characterized by TEM, IR and Raman spectroscopy. • Highly sensitive and selective for glucose determination.

  14. Euglycemic Diabetic Ketoacidosis with Elevated Acetone in a Patient Taking a Sodium-Glucose Cotransporter-2 (SGLT2) Inhibitor.

    Science.gov (United States)

    Andrews, Tory J; Cox, Robert D; Parker, Christina; Kolb, James

    2017-02-01

    Sodium-glucose cotransporter-2 (SGLT2) inhibitor medications are a class of antihyperglycemic agents that increase urinary glucose excretion by interfering with the reabsorption of glucose in the proximal renal tubules. In May of 2015, the U.S. Food and Drug Administration released a warning concerning a potential increased risk of ketoacidosis and ketosis in patients taking these medications. We present a case of a 57-year-old woman with type 2 diabetes mellitus taking a combination of canagliflozin and metformin who presented with progressive altered mental status over the previous 2 days. Her work-up demonstrated a metabolic acidosis with an anion gap of 38 and a venous serum pH of 7.08. The serum glucose was 168 mg/dL. The urinalysis showed glucose > 500 mg/dL and ketones of 80 mg/dL. Further evaluation demonstrated an elevated serum osmolality of 319 mOsm/kg and an acetone concentration of 93 mg/dL. She was treated with intravenous insulin and fluids, and the metabolic abnormalities and her altered mental status resolved within 36 h. This was the first episode of diabetic ketoacidosis (DKA) for this patient. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Diabetic patients on SGLT2 inhibitor medications are at risk for ketoacidosis. Due to the renal glucose-wasting properties of these drugs, they may present with ketoacidosis with only mild elevations in serum glucose, potentially complicating the diagnosis. Acetone is one of the three main ketone bodies formed during DKA and it may be present at considerable concentrations, contributing to the serum osmolality. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Optical coherence tomography for blood glucose monitoring in vitro through spatial and temporal approaches

    Science.gov (United States)

    De Pretto, Lucas Ramos; Yoshimura, Tania Mateus; Ribeiro, Martha Simões; Zanardi de Freitas, Anderson

    2016-08-01

    As diabetes causes millions of deaths worldwide every year, new methods for blood glucose monitoring are in demand. Noninvasive approaches may increase patient adherence to treatment while reducing costs, and optical coherence tomography (OCT) may be a feasible alternative to current invasive diagnostics. This study presents two methods for blood sugar monitoring with OCT in vitro. The first, based on spatial statistics, exploits changes in the light total attenuation coefficient caused by different concentrations of glucose in the sample using a 930-nm commercial OCT system. The second, based on temporal analysis, calculates differences in the decorrelation time of the speckle pattern in the OCT signal due to blood viscosity variations with the addition of glucose with data acquired by a custom built Swept Source 1325-nm OCT system. Samples consisted of heparinized mouse blood, phosphate buffer saline, and glucose. Additionally, further samples were prepared by diluting mouse blood with isotonic saline solution to verify the effect of higher multiple scattering components on the ability of the methods to differentiate glucose levels. Our results suggest a direct relationship between glucose concentration and both decorrelation rate and attenuation coefficient, with our systems being able to detect changes of 65 mg/dL in glucose concentration.

  16. Comparison of the Effectiveness of a Virtual Simulator With a Plastic Arm Model in Teaching Intravenous Catheter Insertion Skills.

    Science.gov (United States)

    Günay İsmailoğlu, Elif; Zaybak, Ayten

    2018-02-01

    The objective of this study was to compare the effectiveness of a virtual intravenous simulator with a plastic arm model in teaching intravenous catheter insertion skills to nursing students. We used a randomized controlled quasi-experimental trial design and recruited 65 students who were assigned to the experimental (n = 33) and control (n = 32) groups using the simple random sampling method. The experimental group received intravenous catheterization skills training on the virtual intravenous simulator, and the control group received the same training on a plastic model of a human arm. Data were collected using the personal information form, intravenous catheterization knowledge assessment form, Intravenous Catheterization Skill Test, Self-Confidence and Satisfaction Scale, and Fear Symptoms Scale. In the study, the mean scores in the control group were 20.44 for psychomotor skills, 15.62 for clinical psychomotor skills, 31.78 for self-confidence, and 21.77 for satisfaction. The mean scores in the experimental group were 45.18 for psychomotor skills, 16.28 for clinical psychomotor skills, 34.18 for self-confidence, and 43.89 for satisfaction. The results indicated that psychomotor skills and satisfaction scores were higher in the experimental group, while the clinical psychomotor skills and self-confidence scores were similar in both groups. More students in the control group reported experiencing symptoms such as cold and sweaty hands, significant restlessness, and tense muscles than those in the experimental group.

  17. Evaluation of the agreement among three handheld blood glucose meters and a laboratory blood analyzer for measurement of blood glucose concentration in Hispaniolan Amazon parrots (Amazona ventralis).

    Science.gov (United States)

    Acierno, Mark J; Mitchell, Mark A; Schuster, Patricia J; Freeman, Diana; Sanchez-Migallon Guzman, David; Tully, Thomas N

    2009-02-01

    To determine the degree of agreement between 3 commercially available point-of-care blood glucose meters and a laboratory analyzer for measurement of blood glucose concentrations in Hispaniolan Amazon parrots (Amazona ventralis). 20 healthy adult Hispaniolan Amazon parrots. A 26-gauge needle and 3-mL syringe were used to obtain a blood sample (approx 0.5 mL) from a jugular vein of each parrot. Small volumes of blood (0.6 to 1.5 microL) were used to operate each of the blood glucose meters, and the remainder was placed into lithium heparin microtubes and centrifuged. Plasma was harvested and frozen at -30 degrees C. Within 5 days after collection, plasma samples were thawed and plasma glucose concentrations were measured by means of the laboratory analyzer. Agreement between pairs of blood glucose meters and between each blood glucose meter and the laboratory analyzer was evaluated by means of the Bland-Altman method, and limits of agreement (LOA) were calculated. None of the results of the 3 blood glucose meters agreed with results of the laboratory analyzer. Each point-of-care blood glucose meter underestimated the blood glucose concentration, and the degree of negative bias was not consistent (meter A bias, -94.9 mg/dL [LOA, -148.0 to -41.7 mg/dL]; meter B bias, -52 mg/dL [LOA, -107.5 to 3.5 mg/dL]; and meter C bias, -78.9 mg/dL [LOA, -137.2 to -20.6 mg/dL]). On the basis of these results, use of handheld blood glucose meters in the diagnosis or treatment of Hispaniolan Amazon parrots and other psittacines cannot be recommended.

  18. Regional cerebral glucose metabolism in patients with alcoholic Korsakoff's syndrome

    International Nuclear Information System (INIS)

    Kessler, R.M.; Parker, E.S.; Clark, C.M.; Martin, P.R.; George, D.T.; Weingartner, H.; Sokoloff, L.; Ebert, M.H.; Mishkin, M.

    1985-01-01

    Seven alcoholic male subjects diagnosed as having Korsakoff's syndrome and eight age-matched male normal volunteers were studied with /sup 18/F 2-fluoro-2-deoxy-D-glucose (2/sup 18/FDG). All subjects were examined at rest with eyes covered in a quiet, darkened room. Serial plasma samples were obtained following injection of 4 to 5 mCi of 2/sup 18/FDG. Tomographic slices spaced at 10mm axial increments were obtained (in-plane resolution = 1.75 cm, axial resolution = 1.78 cm). Four planes were selected from each subject, and a total of 46 regions of interest were sampled and glucose metabolic rates for each region calculated. The mean glucose metalbolic rate for the 46 regions in the Korsakoff subjects was significantly lower than that in the normal controls (5.17 +- .43 versus 6.6 +- 1.31). A Q-component analysis, which examined each subject's regional rates relative to his mean rate, revealed two distinct patterns in the Korsakoff group. Glucose metabolism was significantly reduced in 37 of the 46 regions sampled. Reduced cerebral glucose metabolism in a nondemented group of subjects has not previously been reported. The reduction in cortical metabolism may be the result of damage to sub-cortical projecting systems. The differing patterns of cerebral metabolism in Korsakoff's syndrome suggests subgroups with differing neuropathology. Regions implicated in memory function, medial temporal, thalamic and medial prefrontal were among the regions reduced in metabolism

  19. Dexamethasone increases glucose cycling, but not glucose production, in healthy subjects

    International Nuclear Information System (INIS)

    Wajngot, A.; Khan, A.; Giacca, A.; Vranic, M.; Efendic, S.

    1990-01-01

    We established that measurement of glucose fluxes through glucose-6-phosphatase (G-6-Pase; hepatic total glucose output, HTGO), glucose cycling (GC), and glucose production (HGP), reveals early diabetogenic changes in liver metabolism. To elucidate the mechanism of the diabetogenic effect of glucocorticoids, we treated eight healthy subjects with oral dexamethasone (DEX; 15 mg over 48 h) and measured HTGO with [2-3H]glucose and HGP with [6-3H]glucose postabsorptively and during a 2-h glucose infusion (11.1 mumol.kg-1.min-1). [2-3H]- minus [6-3H]glucose equals GC. DEX significantly increased plasma glucose, insulin, C peptide, and HTGO, while HGP was unchanged. In controls and DEX, glucose infusion suppressed HTGO (82 vs. 78%) and HGP (87 vs. 91%). DEX increased GC postabsorptively (three-fold) P less than 0.005 and during glucose infusion (P less than 0.05) but decreased metabolic clearance and glucose uptake (Rd), which eventually normalized, however. Because DEX increased HTGO (G-6-Pase) and not HGP (glycogenolysis + gluconeogenesis), we assume that DEX increases HTGO and GC in humans by activating G-6-Pase directly, rather than by expanding the glucose 6-phosphate pool. Hyperglycemia caused by peripheral effects of DEX can also contribute to an increase in GC by activating glucokinase. Therefore, measurement of glucose fluxes through G-6-Pase and GC revealed significant early effects of DEX on hepatic glucose metabolism, which are not yet reflected in HGP

  20. Increased glucose dependence in resting, iron-deficient rats

    International Nuclear Information System (INIS)

    Brooks, G.A.; Henderson, S.A.; Dallman, P.R.

    1987-01-01

    Rates of blood glucose and lactate turnover were assessed in resting iron-deficient and iron-sufficient (control) rats to test the hypothesis that dependence on glucose metabolism is increased in iron deficiency. Male Sprague-Dawley rats, 21 days old, were fed a diet containing either 6 mg iron/kg feed (iron-deficient group) or 50 mg iron/kg feed (iron-sufficient group) for 3-4 wk. The iron-deficient group became anemic, with hemoglobin levels of 6.4 ± 0.2 compared with 13.8 ± 0.3 g/dl for controls. Rats received a 90-min primed continuous infusion of D-[6- 3 H]glucose and sodium L-[U- 14 C]lactate via a jugular catheter. Serial samples were taken from a carotid catheter for concentration and specific activity determinations. Iron-deficient rats had significantly higher blood glucose and lactate concentrations than controls. The iron-deficient group had a significantly higher glucose turnover rate than the control group. Significantly more metabolite recycling in iron-deficient rats was indicated by greater incorporation of 14 C into blood glucose. Assuming a carbon crossover correction factor of 2, half of blood glucose arose from lactate in deficient animals. By comparison, only 25% of glucose arose from lactate in controls. Lack of a difference in lactate turnover rates between deficient rats and controls was attributed to 14 C recycling. The results indicate a greater dependence on glucose metabolism in iron-deficient rats

  1. Glucose turnover in 48-hour-fasted running rats

    International Nuclear Information System (INIS)

    Sonne, B.; Mikines, K.J.; Galbo, H.

    1987-01-01

    In fed rats, hyperglycemia develops during exercise. This contrasts with the view based on studies of fasted human and dog that euglycemia is maintained in exercise and glucose production (R/sub a/) controlled by feedback mechanisms. Forty-eight-hour-fasted rats (F) were compared to fed rats (C) and overnight food-restricted (FR) rats. [3- 3 H]- and [U- 14 C]glucose were infused and blood and tissue sampled. During running (21 m/min, 0% grade) R/sub a/ increased most in C and least in F and only in F did R/sub a/ not significantly exceed glucose disappearance. Plasma glucose increased more in C (3.3 mmol/1) than in FR (1.6 mmol/l) and only modestly (0.6 mmol/l) and transiently in F. Resting liver glycogen and exercise glycogenolysis were highest in C and similar in FR and F. Resting muscle glycogen and exercise glycogenolysis were highest in C and lowest in F. During running, lactate production and gluconeogenesis were higher in FR than in F. At least in rats, responses of production and plasma concentration of glucose to exercise depend on size of liver and muscle glycogen stores; glucose production matches increase in clearance better in fasted than in fed states. Probably glucose production is stimulated by feedforward mechanisms and feedback mechanisms are added if plasma glucose decreases

  2. Effects of simulated altitude on blood glucose meter performance: implications for in-flight blood glucose monitoring.

    Science.gov (United States)

    Olateju, Tolu; Begley, Joseph; Flanagan, Daniel; Kerr, David

    2012-07-01

    Most manufacturers of blood glucose monitoring equipment do not give advice regarding the use of their meters and strips onboard aircraft, and some airlines have blood glucose testing equipment in the aircraft cabin medical bag. Previous studies using older blood glucose meters (BGMs) have shown conflicting results on the performance of both glucose oxidase (GOX)- and glucose dehydrogenase (GDH)-based meters at high altitude. The aim of our study was to evaluate the performance of four new-generation BGMs at sea level and at a simulated altitude equivalent to that used in the cabin of commercial aircrafts. Blood glucose measurements obtained by two GDH and two GOX BGMs at sea level and simulated altitude of 8000 feet in a hypobaric chamber were compared with measurements obtained using a YSI 2300 blood glucose analyzer as a reference method. Spiked venous blood samples of three different glucose levels were used. The accuracy of each meter was determined by calculating percentage error of each meter compared with the YSI reference and was also assessed against standard International Organization for Standardization (ISO) criteria. Clinical accuracy was evaluated using the consensus error grid method. The percentage (standard deviation) error for GDH meters at sea level and altitude was 13.36% (8.83%; for meter 1) and 12.97% (8.03%; for meter 2) with p = .784, and for GOX meters was 5.88% (7.35%; for meter 3) and 7.38% (6.20%; for meter 4) with p = .187. There was variation in the number of time individual meters met the standard ISO criteria ranging from 72-100%. Results from all four meters at both sea level and simulated altitude fell within zones A and B of the consensus error grid, using YSI as the reference. Overall, at simulated altitude, no differences were observed between the performance of GDH and GOX meters. Overestimation of blood glucose concentration was seen among individual meters evaluated, but none of the results obtained would have resulted in

  3. Hydrogel-based electrochemical sensor for non-invasive and continuous glucose monitoring

    Science.gov (United States)

    Park, Habeen; Lee, Ji-Young; Kim, Dong-Chul; Koh, Younggook; Cha, Junhoe

    2017-07-01

    Monitoring blood glucose level of diabetic patients is crucial in diabetes care from life threating complications. Selfmonitoring blood glucose (SMBG) that involves finger prick to draw blood samples into the measurement system is a widely-used method of routine measurement of blood glucose levels to date. SMBG includes, however, unavoidable pain problems resulting from the repetitive measurements. We hereby present a hydrogel-based electrochemical (H-EC) sensor to monitor the glucose level, non-invasively. Glucose oxidase (GOx) was immobilized in the disc-type hydroxyethyl methacrylate (HEMA) based hydrogel and kept intact in the hydrogel. Fast electron transfer mediated by Prussian blue (PB, hexacyanoferrate) generated efficient signal amplifications to facilitate the detection of the extracted glucose from the interstitial fluid. The linear response and the selectivity against glucose of the H-EC sensor were validated by chronoamperometry. For the practical use, the outcomes from the correlation of the extracted glucose concentration and the blood glucose value by on-body extraction, as well as the validation of the hydrogel-based electrochemical (H-EC) device, were applied to the on-body glucose monitoring.

  4. Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients.

    Science.gov (United States)

    Uemura, Mei; Yano, Yutaka; Suzuki, Toshinari; Yasuma, Taro; Sato, Toshiyuki; Morimoto, Aya; Hosoya, Samiko; Suminaka, Chihiro; Nakajima, Hiromu; Gabazza, Esteban C; Takei, Yoshiyuki

    2017-08-01

    Continuous glucose monitoring (CGM) is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC) monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET). Here we evaluated the accuracy of interstitial fluid glucose (IG) AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting hyperglycemia using CGM data as a reference. Thirty-eight inpatients with diabetes undergoing CGM were enrolled. MIET comprised a pretreatment step using a plastic microneedle array and glucose accumulation step with a hydrogel patch, which was placed on two sites from 9:00 AM to 5:00 PM or from 10:00 PM to 6:00 AM. IG AUC was calculated by accumulated glucose extracted by hydrogel patches using sodium ion as standard. A significant correlation was observed between the predicted AUC by MIET and CGM in daytime (r=0.76) and nighttime (r=0.82). The optimal cutoff for the IG AUC value of MIET to predict hyperglycemia over 200 mg/dL measured by CGM for 8 hours was 1,067.3 mg·hr/dL with 88.2% sensitivity and 81.5% specificity. We showed that 8-hour IG AUC levels using MIET were valuable in estimating the blood glucose AUC without blood sampling. The results also supported the concept of using this technique for evaluating glucose excursion and for screening hyperglycemia during 8 hours in patients with diabetes at any time of day. Copyright © 2017 Korean Diabetes Association

  5. Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Mei Uemura

    2017-07-01

    Full Text Available BackgroundContinuous glucose monitoring (CGM is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET. Here we evaluated the accuracy of interstitial fluid glucose (IG AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting hyperglycemia using CGM data as a reference.MethodsThirty-eight inpatients with diabetes undergoing CGM were enrolled. MIET comprised a pretreatment step using a plastic microneedle array and glucose accumulation step with a hydrogel patch, which was placed on two sites from 9:00 AM to 5:00 PM or from 10:00 PM to 6:00 AM. IG AUC was calculated by accumulated glucose extracted by hydrogel patches using sodium ion as standard. ResultsA significant correlation was observed between the predicted AUC by MIET and CGM in daytime (r=0.76 and nighttime (r=0.82. The optimal cutoff for the IG AUC value of MIET to predict hyperglycemia over 200 mg/dL measured by CGM for 8 hours was 1,067.3 mg·hr/dL with 88.2% sensitivity and 81.5% specificity.ConclusionWe showed that 8-hour IG AUC levels using MIET were valuable in estimating the blood glucose AUC without blood sampling. The results also supported the concept of using this technique for evaluating glucose excursion and for screening hyperglycemia during 8 hours in patients with diabetes at any time of day.

  6. comparative study of glucose homeostasis, lipids and lipoproteins, HDL functionality, and cardiometabolic parameters in modestly severely obese African Americans and White Americans with prediabetes: implications for the metabolic paradoxes.

    Science.gov (United States)

    Healy, Sara J; Osei, Kwame; Gaillard, Trudy

    2015-02-01

    To determine whether modestly severe obesity modifies glucose homeostasis, levels of cardiometabolic markers, and HDL function in African Americans (AAs) and white Americans (WAs) with prediabetes. We studied 145 subjects with prediabetes (N = 61 WAs, N = 84 AAs, mean age 46.5 ± 11.2 years, mean BMI 37.8 ± 6.3 kg/m(2)). We measured fasting levels of lipids, lipoproteins, and an inflammatory marker (C-reactive protein [CRP]); HDL functionality (i.e., levels of paraoxonase 1 [PON1]); and levels of oxidized LDL, adiponectin, and interleukin-6 (IL-6). We measured serum levels of glucose, insulin, and C-peptide during an oral glucose tolerance test. Values for insulin sensitivity index (Si), glucose effectiveness index (Sg), glucose effectiveness at zero insulin (GEZI), and acute insulin response to glucose (AIRg) were derived using a frequently sampled intravenous glucose tolerance test (using MINMOD software). Mean levels of fasting and incremental serum glucose, insulin, and C-peptide tended to be higher in WAs versus AAs. The mean Si was not different in WAs versus AAs (2.6 ± 2.3 vs. 2.9 ± 3.0 × 10(-4) × min(-1) [μU/mL](-1)). Mean values for AIRg and disposition index as well as Sg and GEZI were lower in WAs than AAs. WAs had higher serum triglyceride levels than AAs (116.1 ± 55.5 vs. 82.7 ± 44.2 mg/dL, P = 0.0002). Mean levels of apolipoprotein (apo) A1, HDL cholesterol, PON1, oxidized LDL, CRP, adiponectin, and IL-6 were not significantly different in obese AAs versus WAs with prediabetes. Modestly severe obesity attenuated the ethnic differences in Si, but not in Sg and triglyceride levels in WAs and AAs with prediabetes. Despite the lower Si and PON1 values, AAs preserved paradoxical relationships between the Si and HDL/apoA1/triglyceride ratios. We conclude that modestly severe obesity has differential effects on the pathogenic mechanisms underlying glucose homeostasis and atherogenesis in obese AAs and WAs with prediabetes. © 2015 by the American

  7. Relationships between the pituitary-adrenal hormones, insulin, and glucose in middle-aged men: moderating influence of psychosocial stress.

    Science.gov (United States)

    Keltikangas-Järvinen, L; Ravaja, N; Räikkönen, K; Hautanen, A; Adlercreutz, H

    1998-12-01

    We examined whether the relationships between the pituitary-adrenal hormones (corticotropin [ACTH) and cortisol), insulin, and glucose differ as a function of psychosocial stress defined in terms of vital exhaustion (VE) and depressive behavior (DB). The participants were 69 normotensive and 21 unmedicated borderline hypertensive (BH) middle-aged men whose work is stressful. Hormonal and metabolic variables were measured during an oral glucose tolerance test (OGTT), and the cortisol response to dexamethasone (DXM) suppression and intravenous ACTH stimulation was also measured. We found that the basal ACTH level during the OGTT was positively associated with the cortisol response to ACTH at 60 minutes, the fasting insulin level, and the insulin to glucose ratio among exhausted and high DB men, while the reverse was true for nonexhausted and low DB men. Also, a high cortisol response to ACTH, a low cortisol level during the OGTT, and a high ratio of these cortisol determinations (cortisol ratio) were associated with high fasting insulin and glucose levels, the summed insulin values, and the insulin to glucose ratio only among nonexhausted and low DB men; among exhausted and high DB men, these associations were less pronounced, absent, or in the opposite direction. The findings suggest that VE and DB have a moderating influence on the relationships among the hormonal and metabolic parameters studied. Psychosocial stress may affect the pituitary-adrenocortical system in complex ways, contributing thereby to insulin resistance, hyperinsulinemia, and coronary heart disease (CHD) risk.

  8. Effects of CDP-choline on neurologic deficits and cerebral glucose metabolism in a rat model of cerebral ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Kakihana, M.; Fukuda, N.; Suno, M.; Nagaoka, A.

    1988-02-01

    The effects of cytidine 5'-diphosphocholine (CDP-choline) on neurologic deficits and cerebral glucose metabolism were studied in a rat model of transient cerebral ischemia. Cerebral ischemia was induced by occluding both common carotid arteries for 20 or 30 minutes 24 hours after the vertebral arteries were permanently occluded by electrocautery. CDP-choline was administered intraperitoneally twice daily for 4 days after reestablishing carotid blood flow. CDP-choline at two dosages (50 and 250 mg/kg) shortened the time required for recovery of spontaneous motor activity in a dose-related manner; recovery time was measured early after reperfusion. Neurologic signs were observed for 10 days. High-dose CDP-choline improved neurologic signs in the rats within 20-30 minutes of ischemia. When cerebral glucose metabolism was assessed on Day 4, increases in the levels of glucose and pyruvate were accompanied by decreases in the synthesis of labeled acetylcholine from uniformly labeled (/sup 14/C)glucose measured in the cerebral cortex of rats with 30 minutes of ischemia. High-dose CDP-choline also attenuated changes in these variables. CDP-(1,2-/sup 14/C)choline injected intravenously 10 minutes after reperfusion was used for membrane lipid biosynthesis. These results indicate that CDP-choline has beneficial effects on brain dysfunction induced by cerebral ischemia, which may be due in part to the restorative effects of CDP-choline on disturbed cerebral glucose metabolism, probably by stimulating phospholipid biosynthesis.

  9. Effects of CDP-choline on neurologic deficits and cerebral glucose metabolism in a rat model of cerebral ischemia

    International Nuclear Information System (INIS)

    Kakihana, M.; Fukuda, N.; Suno, M.; Nagaoka, A.

    1988-01-01

    The effects of cytidine 5'-diphosphocholine (CDP-choline) on neurologic deficits and cerebral glucose metabolism were studied in a rat model of transient cerebral ischemia. Cerebral ischemia was induced by occluding both common carotid arteries for 20 or 30 minutes 24 hours after the vertebral arteries were permanently occluded by electrocautery. CDP-choline was administered intraperitoneally twice daily for 4 days after reestablishing carotid blood flow. CDP-choline at two dosages (50 and 250 mg/kg) shortened the time required for recovery of spontaneous motor activity in a dose-related manner; recovery time was measured early after reperfusion. Neurologic signs were observed for 10 days. High-dose CDP-choline improved neurologic signs in the rats within 20-30 minutes of ischemia. When cerebral glucose metabolism was assessed on Day 4, increases in the levels of glucose and pyruvate were accompanied by decreases in the synthesis of labeled acetylcholine from uniformly labeled [ 14 C]glucose measured in the cerebral cortex of rats with 30 minutes of ischemia. High-dose CDP-choline also attenuated changes in these variables. CDP-[1,2- 14 C]choline injected intravenously 10 minutes after reperfusion was used for membrane lipid biosynthesis. These results indicate that CDP-choline has beneficial effects on brain dysfunction induced by cerebral ischemia, which may be due in part to the restorative effects of CDP-choline on disturbed cerebral glucose metabolism, probably by stimulating phospholipid biosynthesis

  10. Imaging of chest disease due to intravenous heroin abuse

    International Nuclear Information System (INIS)

    Lian Xuhui; Chen Zhong; Ye Wenqin

    2002-01-01

    Objective: To study the imaging findings of the chest disease due to intravenous heroin abuse. Methods: Twenty-five cases of clinically confirmed chest disease due to intravenous heroin abuse were retrospectively analyzed. 25 cases had conventional X-ray film, 6 cases had CT scanning, and 6 cases had echocardiography scanning. Results: On X-ray and CT, the following signs were found: lung making manifold (n = 5), small patchy shadow (n = 15), pneumatocele (n = 16), small cavity (n = 16), small node (n = 7), pleural effusion (n = 8 ), pneumothorax (n = 2), hydropneumothorax (n = 6), pulmonary edema (n = 2), megacardia (n = 11), multiple-shaped lesion (n = 20). On echocardiography, tricuspid vegetation (n = 4) and tricuspid insufficiency (n = 4) were found. Conclusion: The X-ray and CT manifestations of chest inflammation due to intravenous heroin abuse are multiple. The multiple small cavities and pneumatoceles sign are of some value in the diagnosis of lung inflammation due to intravenous heroin abuse among young patients

  11. Catheter indwell time and phlebitis development during peripheral intravenous catheter administration.

    Science.gov (United States)

    Pasalioglu, Kadriye Burcu; Kaya, Hatice

    2014-07-01

    Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance.

  12. Thermogenic Effect of Glucose in Hypothyroid Subjects

    Directory of Open Access Journals (Sweden)

    Agnieszka Kozacz

    2014-01-01

    Full Text Available The importance of thyroid hormone, catecholamines, and insulin in modification of the thermogenic effect of glucose (TEG was examined in 34 healthy and 32 hypothyroid subjects. We calculated the energy expenditure at rest and during oral glucose tolerance test. Blood samples for determinations of glucose, plasma insulin, adrenaline (A, and noradrenaline (NA were collected. It was found that TEG was lower in hypothyroid than in control group (19.68±3.90 versus 55.40±7.32 kJ, resp., P<0.0004. Mean values of glucose and insulin areas under the curve were higher in women with hypothyroidism than in control group (286.79±23.65 versus 188.41±15.84 mmol/L·min, P<0.003 and 7563.27±863.65 versus 4987.72±583.88 mU/L·min, P<0.03 resp.. Maximal levels of catecholamines after glucose ingestion were higher in hypothyroid patients than in control subjects (Amax—0.69±0.08 versus 0.30±0.07 nmol/L, P<0.0001, and NAmax—6.42±0.86 versus 2.54±0.30 nmol/L, P<0.0002. It can be concluded that in hypothyroidism TEG and glucose tolerance are decreased while the adrenergic response to glucose administration is enhanced. Presumably, these changes are related to decreased insulin sensitivity and responsiveness to catecholamine action.

  13. Intravenous nitroglycerin for external cephalic version: a randomized controlled trial.

    Science.gov (United States)

    Hilton, Jennifer; Allan, Bruce; Swaby, Cheryl; Wahba, Raouf; Wah, Raouf; Jarrell, John; Wood, Stephen; Ross, Sue; Tran, Quynh

    2009-09-01

    To estimate whether treatment with intravenous nitroglycerin for uterine relaxation increases the chance of successful external cephalic version. Two double-blind, randomized clinical trials were undertaken: one in nulliparous women and a second in multiparous women. Women presenting for external cephalic version at term were eligible to participate. The primary outcome was immediate success of external cephalic version. Other outcomes were presentation at delivery, cesarean delivery rate, and side effects and complications. Sample size calculations were based on a 100% increase in success of external cephalic version with a one-sided analysis and alpha=0.05 (80% power). In total, 126 women were recruited-82 in the nulliparous trial and 44 in the multiparous trial. Seven patients did not have external cephalic version before delivery but were included in the analysis of success of external cephalic version. One patient was lost to follow-up. The external cephalic version success rate for nulliparous patients was 24% (10 of 42) in patients who received nitroglycerin compared with 8% (3 of 40) in those who receive placebo (P=.04, one-sided Fisher exact test, odds ratio 3.85, lower bound 1.22). In multiparous patients, the external cephalic version success rate did not differ significantly between groups: 44% (10 of 23) in the nitroglycerin group compared with 43% (9 of 21) in the placebo group (P=.60). Treatment with intravenous nitroglycerin increased the rate of successful external cephalic version in nulliparous, but not in multiparous, women. Treatment with intravenous nitroglycerin appeared to be safe, but our numbers were too small to rule out rare serious adverse effects. I.

  14. Distribution and pharmacokinetics of radiolabeled monoclonal antibody OC 125 after intravenous and intraperitoneal administration in gynecologic tumors

    International Nuclear Information System (INIS)

    Haisma, H.J.; Moseley, K.R.; Battaile, A.; Griffiths, T.C.; Knapp, R.C.

    1988-01-01

    Radiolabeled monoclonal antibodies may be useful for radioimmunotherapy of gynecologic tumors. Iodine 131-labeled F(ab')2 fragments of a monoclonal antibody, OC 125, with specificity for ovarian carcinoma, were used to study the distribution and pharmacokinetics of this antibody in patients with gynecologic tumors. The radiolabeled antibody was injected intravenously or intraperitoneally into 10 patients suspected of having ovarian cancer. Blood and urine samples were used for pharmacokinetic studies, and biopsy specimens were examined for the uptake of antibody. The serum half-life of the labeled antibody was 30 hours after intravenous administration, with 20% of the injected dose per liter detected at 24 hours. After intraperitoneal injection, the appearance of antibody in serum was slow, with a maximum level of 1.4% of the injected dose per liter at 24 hours. Urinary excretion of the radiolabeled antibody was similar for intravenous and intraperitoneal administration, with approximately 50% of the injected dose excreted after 48 hours. Intraperitoneal administration of the radiolabeled antibody resulted in a higher uptake of antibody in the tumor and a lower uptake of antibody in normal tissues. On the basis of this limited study, intraperitoneal administration of radiolabeled antibody is preferred over intravenous administration for radioimmunotherapy of ovarian cancer

  15. High reproducibility and sensitivity of bifacial copper nanowire array for detection of glucose

    Directory of Open Access Journals (Sweden)

    Hanqing Zhang

    2017-06-01

    Full Text Available The ordered bifacial copper nanowire array (Cu BNWA was synthesized by a template assisted electrochemical deposition method. The morphology and structure of the as-prepared samples were investigated by field emission scanning electron microscope (FESEM and X-ray diffraction (XRD. The results show that the ordered Cu nanowire array with uniform geometrical dimensions covered both side of the Cu substrate. When used as the electrode for glucose detection, the minimum detectable concentration of glucose can be reached as low as 0.2 mM. Impressively, the sample still showed high sensitivity and stability for glucose detection after two months placement in ambient environment. These excellent performances of the Cu BNWA make it a promising non-enzyme glucose detection sensor for various applications.

  16. Non-Enzymatic Glucose Sensing Using Carbon Quantum Dots Decorated with Copper Oxide Nanoparticles

    Directory of Open Access Journals (Sweden)

    Houcem Maaoui

    2016-10-01

    Full Text Available Perturbations in glucose homeostasis is critical for human health, as hyperglycemia (defining diabetes leads to premature death caused by macrovascular and microvascular complications. However, the simple and accurate detection of glucose in the blood at low cost remains a challenging task, although it is of great importance for the diagnosis and therapy of diabetic patients. In this work, carbon quantum dots decorated with copper oxide nanostructures (CQDs/Cu2O are prepared by a simple hydrothermal approach, and their potential for electrochemical non-enzymatic glucose sensing is evaluated. The proposed sensor exhibits excellent electrocatalytic activity towards glucose oxidation in alkaline solutions. The glucose sensor is characterized by a wide concentration range from 6 µM to 6 mM, a sensitivity of 2.9 ± 0.2 µA·µM−1·cm−2, and a detection limit of 6 µM at a signal-to-noise ratio S/N = 3. The sensors are successfully applied for glucose determination in human serum samples, demonstrating that the CQDs/Cu2O-based glucose sensor satisfies the requirements of complex sample detection with adapted potential for therapeutic diagnostics.

  17. Measuring brain glucose phosphorylation with labeled glucose

    International Nuclear Information System (INIS)

    Brondsted, H.E.; Gjedde, A.

    1988-01-01

    This study tested whether glucose labeled at the C-6 position generates metabolites that leave brain so rapidly that C-6-labeled glucose cannot be used to measure brain glucose phosphorylation (CMRGlc). In pentobarbital-anesthetized rats, the parietal cortex uptake of [ 14 C]glucose labeled in the C-6 position was followed for times ranging from 10 s to 60 min. We subtracted the observed radioactivity from the radioactivity expected with no loss of labeled metabolites from brain by extrapolation of glucose uptake in an initial period when loss was negligible. The observed radioactivity was a monoexponentially declining function of the total radioactivity expected in the absence of metabolite loss. The constant of decline was 0.0077.min-1 for parietal cortex. Metabolites were lost from the beginning of the experiment. However, with correction for the loss of labeled metabolites, it was possible to determine an average CMRGlc between 4 and 60 min of circulation of 64 +/- 4 (SE; n = 49) mumol.hg-1.min-1

  18. Rationale and design of the Aquapheresis Versus Intravenous Diuretics and Hospitalization for Heart Failure (AVOID-HF) trial.

    Science.gov (United States)

    Costanzo, Maria Rosa; Negoianu, Daniel; Fonarow, Gregg C; Jaski, Brian E; Bart, Bradley A; Heywood, J Thomas; Nabut, Jose L; Schollmeyer, Michael P

    2015-09-01

    In patients hospitalized with acutely decompensated heart failure, unresolved signs and symptoms of fluid overload have been consistently associated with poor outcomes. Regardless of dosing and type of administration, intravenous loop diuretics have not reduced heart failure events or mortality in patients with acutely decompensated heart failure. The results of trials comparing intravenous loop diuretics to mechanical fluid removal by isolated venovenous ultrafiltration have yielded conflicting results. Studies evaluating early decongestive strategies have shown that ultrafiltration removed more fluid and was associated with fewer heart failure-related rehospitalization than intravenous loop diuretics. In contrast, when used in the setting of worsening renal function, ultrafiltration was associated with poorer renal outcomes and no reduction in heart failure events. The AVOID-HF trial seeks to determine if an early strategy of ultrafiltration in patients with acutely decompensated heart failure is associated with fewer heart failure events at 90 days compared with a strategy based on intravenous loop diuretics. Study subjects from 40 highly experienced institutions are randomized to either early ultrafiltration or intravenous loop diuretics. In both treatment arms, fluid removal therapies are adjusted according to the patients' hemodynamic condition and renal function. The study was unilaterally terminated by the sponsor in the absence of futility and safety concerns after the enrollment of 221 subjects, or 27% of the originally planned sample size of 810 patients. The AVOID-HF trial's principal aim is to compare the safety and efficacy of ultrafiltration vs that of intravenous loop diuretics in patients hospitalized with acutely decompensated heart failure. Because stepped treatment approaches are applied in both ultrafiltration and intravenous loop diuretics groups and the primary end point is time to first heart failure event within 90 days, it is hoped that

  19. Intravenous to oral conversion of fluoroquinolones: knowledge versus clinical practice patterns.

    Science.gov (United States)

    Conort, Ornella; Gabardi, Steven; Didier, Marie-Pauline; Hazebroucq, Georges; Cariou, Alain

    2002-04-01

    To assess the knowledge of prescribers regarding intravenous to oral conversions of fluoroquinolones, the frequency and time until conversion, and to compare prescriber knowledge with the data collected concerning the reasons stated for continuation of intravenous fluoroquinolones. Prospective chart review and questionnaire. Large teaching hospital in Paris, France. Fifty-one males and females. Data were collected on in-patients receiving intravenous fluoroquinolone for at least three days and hospitalized in one of six in-patient units. Patients receiving intravenous fluoroquinolone for less than three days were excluded. A questionnaire to assess the awareness of a potential conversion was distributed to those practitioners who had patients reviewed during the data-collection phase. The questionnaire revealed the ten most common reasons for continuing intravenous administration for more than three days. However, the physicians agreed that most patients should be converted as soon as possible. Practice patterns differed, with only 17 of 51 patients actually converted to oral therapy. In theory, the clinicians were aware of when to perform the conversion. However, in practice, the frequency of conversion was lower than optimum. Changes in clinical practice are needed to decrease the costs of intravenous therapy, without jeopardizing quality of care.

  20. Profiling and Quantification of Regioisomeric Caffeoyl Glucoses in Berry Fruits.

    Science.gov (United States)

    Patras, Maria A; Jaiswal, Rakesh; McDougall, Gordon J; Kuhnert, Nikolai

    2018-02-07

    On the basis of a recently developed tandem mass spectrometry-based hierarchical scheme for the identification of regioisomeric caffeoyl glucoses, selected berry fruits were profiled for their caffeoyl glucose ester content. Fresh edible berries profiled, including strawberries, raspberries, blueberries, blackberries, red currant, black currant, lingonberries, gooseberries, and juices of elderberries, goji berries, chokeberries, cranberries, açai berries, sea buckthorn berries, Montmorency sour cherries, and pomegranates, were investigated. 1-Caffeoyl glucose was found to be the predominant isomer in the majority of samples, with further profiling revealing the presence of additional hydroxycinnamoyl glucose esters and O-glycosides with p-coumaroyl, feruloyl, and sinapoyl substituents. A quantitative liquid chromatography-mass spectrometry-based method was developed and validated, and all caffeoyl glucose isomers were quantified for the first time in edible berries.

  1. Optimal timing for intravenous administration set replacement.

    Science.gov (United States)

    Gillies, D; O'Riordan, L; Wallen, M; Morrison, A; Rankin, K; Nagy, S

    2005-10-19

    Administration of intravenous therapy is a common occurrence within the hospital setting. Routine replacement of administration sets has been advocated to reduce intravenous infusion contamination. If decreasing the frequency of changing intravenous administration sets does not increase infection rates, a change in practice could result in considerable cost savings. The objective of this review was to identify the optimal interval for the routine replacement of intravenous administration sets when infusate or parenteral nutrition (lipid and non-lipid) solutions are administered to people in hospital via central or peripheral venous catheters. We searched The Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, CINAHL, EMBASE: all from inception to February 2004; reference lists of identified trials, and bibliographies of published reviews. We also contacted researchers in the field. We did not have a language restriction. We included all randomized or quasi-randomized controlled trials addressing the frequency of replacing intravenous administration sets when parenteral nutrition (lipid and non-lipid containing solutions) or infusions (excluding blood) were administered to people in hospital via a central or peripheral catheter. Two authors assessed all potentially relevant studies. We resolved disagreements between the two authors by discussion with a third author. We collected data for the outcomes; infusate contamination; infusate-related bloodstream infection; catheter contamination; catheter-related bloodstream infection; all-cause bloodstream infection and all-cause mortality. We identified 23 references for review. We excluded eight of these studies; five because they did not fit the inclusion criteria and three because of inadequate data. We extracted data from the remaining 15 references (13 studies) with 4783 participants. We conclude that there is no evidence that changing intravenous administration sets more often than every 96 hours

  2. Acute effect of oral, intraperitoneal, and intravenous 1 alpha-hydroxycholecalciferol on markers of bone metabolism

    DEFF Research Database (Denmark)

    Joffe, P; Ladefoged, S D; Cintin, C

    1994-01-01

    ,25-(OH)2D3 was measured. DESIGN: Single doses of 1 alpha-OHD3 (80 ng/kg body wt) were given in randomized cross-over fashion, orally, intraperitoneally (i.p.) and intravenously (i.v.) on three occasions. Blood was sampled at 0, 1, 6, 12, and 24 h after administration of 1 alpha-OHD3. MAIN RESULTS...

  3. A signal processing application for evaluating self-monitoring blood glucose strategies in a software agent model.

    Science.gov (United States)

    Wang, Zhanle; Paranjape, Raman

    2015-07-01

    We propose the signal processing technique of calculating a cross-correlation function and an average deviation between the continuous blood glucose and the interpolation of limited blood glucose samples to evaluate blood glucose monitoring frequency in a self-aware patient software agent model. The diabetic patient software agent model [1] is a 24-h circadian, self-aware, stochastic model of a diabetic patient's blood glucose levels in a software agent environment. The purpose of this work is to apply a signal processing technique to assist patients and physicians in understanding the extent of a patient's illness using a limited number of blood glucose samples. A second purpose of this work is to determine an appropriate blood glucose monitoring frequency in order to have a minimum number of samples taken that still provide a good understanding of the patient's blood glucose levels. For society in general, the monitoring cost of diabetes is an extremely important issue, and these costs can vary tremendously depending on monitoring approaches and monitoring frequencies. Due to the cost and discomfort associated with blood glucose monitoring, today, patients expect monitoring frequencies specific to their health profile. The proposed method quantitatively assesses various monitoring protocols (from 6 times per day to 1 time per week) in nine predefined categories of patient agents in terms of risk factors of health status and age. Simulation results show that sampling 6 times per day is excessive, and not necessary for understanding the dynamics of the continuous signal in the experiments. In addition, patient agents in certain conditions only need to sample their blood glucose 1 time per week to have a good understanding of the characteristics of their blood glucose. Finally, an evaluation scenario is developed to visualize this concept, in which appropriate monitoring frequencies are shown based on the particular conditions of patient agents. This base line can

  4. Dietary fructose and glucose differentially affect lipid and glucose homeostasis.

    Science.gov (United States)

    Schaefer, Ernst J; Gleason, Joi A; Dansinger, Michael L

    2009-06-01

    Absorbed glucose and fructose differ in that glucose largely escapes first-pass removal by the liver, whereas fructose does not, resulting in different metabolic effects of these 2 monosaccharides. In short-term controlled feeding studies, dietary fructose significantly increases postprandial triglyceride (TG) levels and has little effect on serum glucose concentrations, whereas dietary glucose has the opposite effects. When dietary glucose and fructose have been directly compared at approximately 20-25% of energy over a 4- to 6-wk period, dietary fructose caused significant increases in fasting TG and LDL cholesterol concentrations, whereas dietary glucose did not, but dietary glucose did increase serum glucose and insulin concentrations in the postprandial state whereas dietary fructose did not. When fructose at 30-60 g ( approximately 4-12% of energy) was added to the diet in the free-living state, there were no significant effects on lipid or glucose biomarkers. Sucrose and high-fructose corn syrup (HFCS) contain approximately equal amounts of fructose and glucose and no metabolic differences between them have been noted. Controlled feeding studies at more physiologic dietary intakes of fructose and glucose need to be conducted. In our view, to decrease the current high prevalence of obesity, dyslipidemia, insulin resistance, and diabetes, the focus should be on restricting the intake of excess energy, sucrose, HFCS, and animal and trans fats and increasing exercise and the intake of vegetables, vegetable oils, fish, fruit, whole grains, and fiber.

  5. Intravenous Iron Carboxymaltose as a Potential Therapeutic in Anemia of Inflammation.

    Directory of Open Access Journals (Sweden)

    Niklas Lofruthe

    Full Text Available Intravenous iron supplementation is an effective therapy in iron deficiency anemia (IDA, but controversial in anemia of inflammation (AI. Unbound iron can be used by bacteria and viruses for their replication and enhance the inflammatory response. Nowadays available high molecular weight iron complexes for intravenous iron substitution, such as ferric carboxymaltose, might be useful in AI, as these pharmaceuticals deliver low doses of free iron over a prolonged period of time. We tested the effects of intravenous iron carboxymaltose in murine AI: Wild-type mice were exposed to the heat-killed Brucella abortus (BA model and treated with or without high molecular weight intravenous iron. 4h after BA injection followed by 2h after intravenous iron treatment, inflammatory cytokines were upregulated by BA, but not enhanced by iron treatment. In long term experiments, mice were fed a regular or an iron deficient diet and then treated with intravenous iron or saline 14 days after BA injection. Iron treatment in mice with BA-induced AI was effective 24h after iron administration. In contrast, mice with IDA (on iron deficiency diet prior to BA-IA required 7d to recover from AI. In these experiments, inflammatory markers were not further induced in iron-treated compared to vehicle-treated BA-injected mice. These results demonstrate that intravenous iron supplementation effectively treated the murine BA-induced AI without further enhancement of the inflammatory response. Studies in humans have to reveal treatment options for AI in patients.

  6. Enhancing the accuracy of subcutaneous glucose sensors: a real-time deconvolution-based approach.

    Science.gov (United States)

    Guerra, Stefania; Facchinetti, Andrea; Sparacino, Giovanni; Nicolao, Giuseppe De; Cobelli, Claudio

    2012-06-01

    Minimally invasive continuous glucose monitoring (CGM) sensors can greatly help diabetes management. Most of these sensors consist of a needle electrode, placed in the subcutaneous tissue, which measures an electrical current exploiting the glucose-oxidase principle. This current is then transformed to glucose levels after calibrating the sensor on the basis of one, or more, self-monitoring blood glucose (SMBG) samples. In this study, we design and test a real-time signal-enhancement module that, cascaded to the CGM device, improves the quality of its output by a proper postprocessing of the CGM signal. In fact, CGM sensors measure glucose in the interstitium rather than in the blood compartment. We show that this distortion can be compensated by means of a regularized deconvolution procedure relying on a linear regression model that can be updated whenever a pair of suitably sampled SMBG references is collected. Tests performed both on simulated and real data demonstrate a significant accuracy improvement of the CGM signal. Simulation studies also demonstrate the robustness of the method against departures from nominal conditions, such as temporal misplacement of the SMBG samples and uncertainty in the blood-to-interstitium glucose kinetic model. Thanks to its online capabilities, the proposed signal-enhancement algorithm can be used to improve the performance of CGM-based real-time systems such as the hypo/hyper glycemic alert generators or the artificial pancreas.

  7. Glucose (xylose) isomerase production from thermotolerant and ...

    African Journals Online (AJOL)

    Owner

    2012-11-13

    Nov 13, 2012 ... in the production of the high fructose corn syrup (HFCS) from corn starch. ... Key words: Glucose isomerase, xylose isomerase, enzyme activity, Klebsiella, ... Soil, water, and manure (five samples each) were collected from.

  8. Brain Glucose Metabolism Controls Hepatic Glucose and Lipid Production

    OpenAIRE

    Lam, Tony K.T.

    2007-01-01

    Brain glucose-sensing mechanisms are implicated in the regulation of feeding behavior and hypoglycemic-induced hormonal counter-regulation. This commentary discusses recent findings indicating that the brain senses glucose to regulate both hepatic glucose and lipid production.

  9. Microdialysis combined blood sampling technique for the determination of rosiglitazone and glucose in brain and blood of gerbils subjected to cerebral ischemia.

    Science.gov (United States)

    Sheu, Wayne H-H; Chuang, Hsiu-Chun; Cheng, Shiu-Min; Lee, Maw-Rong; Chou, Chi-Chi; Cheng, Fu-Chou

    2011-03-25

    Rosiglitazone is a potent synthetic peroxisome proliferator-activated receptor-gamma (PPAR-γ) agonist which improves glucose control in the plasma and reduces ischemic brain injury. However, the pharmacokinetics of rosiglitazone in the brain is still unclear. In this study, a method using liquid chromatography-mass spectrometry coupled with microdialysis and an auto-blood sampling system was developed to determine rosiglitazone and glucose concentration in the brain and blood of gerbils subjected to treatment with rosiglitazone (3.0 mg kg(-1), i.p.). The results showed the limit of detection was 0.04 μg L(-1) and the correlation coefficient was 0.9997 for the determination of rosiglitazone in the brain. The mean parameters, maximum drug concentration (C(max)) and the area under the concentration-time curve from time zero to time infinity (AUC(inf)), following rosiglitazone administration were 1.06±0.28 μg L(-1) and 296.82±44.67 μg min L(-1), respectively. The time to peak concentration (C(max) or T(max)) of rosiglitazone occurred at 105±17.10 min, and the mean elimination half-life (t(1/2)) from brain was 190.81±85.18 min after administration of rosiglitazone. The brain glucose levels decreased to 71% of the basal levels in the rosiglitazone-treated group when compared with those in the control (pblood glucose levels to 80% at 1h after pretreatment of rosiglitazone (pglucose concentrations in brain and plasma. Rosiglitazone was effective at penetrating the blood-brain barrier as evidenced by the rapid appearance of rosiglitazone in the brain, and rosiglitazone may contribute to a reduction in the extent of injuries related to cerebral ischemic stroke via its hypoglycemic effect. Copyright © 2010 Elsevier B.V. All rights reserved.

  10. Effects of a transmitted light device for pediatric peripheral venipuncture and intravenous cannulation

    Directory of Open Access Journals (Sweden)

    Yamazaki S

    2011-10-01

    Full Text Available Shinya Yamazaki1, Shu Tomita1, Masahiro Watanabe1, Hiroyoshi Kawaai1, Kazuhiro Shimamura2 1Department of Dental Anesthesiology; 2Department of Pediatric Dentistry, Ohu University Dental Hospital, Koriyama City, Fukushima Prefecture, Japan Abstract: Pediatric peripheral venipuncture and intravenous cannulation are difficult. However, successful venipuncture and intravenous cannulation are absolutely required for pediatric clinical risk management. This study assessed the success rate of venipuncture and intravenous cannulation when transmitted light was applied to the pediatric dorsum manus. The subjects included 100 young children who were scheduled for dental treatment or oral surgery under general anesthesia. Anesthesia was induced, and insertion of an intravenous catheter into the dorsum manus was attempted with or without using transmitted light. The patients were evaluated to determine whether the venipuncture was successful, and whether the intravenous cannulation of the external catheter was successful. The success rate of venipuncture was 100% when transmitted light was used, and 83% when the transmitted light was not used (P = 0.000016. In addition, the success rate of intravenous cannulation was 88% when transmitted light was used, and 55% when the transmitted light was not used (P = 0.0000002. The shape of the vein in the dorsum manus can be clearly recognized when transmitted light is used. The use of light significantly increased the success rate of intravenous cannulation, because it allowed direct confirmation of the direction to push the intravenous catheter forward. The use of transmitted light allows for more successful venipuncture and intravenous cannulation in young children. Keywords: transmitted light, pediatric peripheral venipuncture, pediatric peripheral intravenous cannulation

  11. Effect of glucose on the biomechanical function of arterial elastin.

    Science.gov (United States)

    Wang, Yunjie; Zeinali-Davarani, Shahrokh; Davis, Elaine C; Zhang, Yanhang

    2015-09-01

    Elastin is essential to provide elastic support for blood vessels. As a remarkably long-lived protein, elastin can suffer from cumulative effects of exposure to biochemical damages, which can greatly compromise its biomechanical properties. Non-enzymatic glycation is one of the main mechanisms of aging and its effect is magnified in diabetic patients. The purpose of this study is to investigate the effects of glucose on mechanical properties of isolated porcine aortic elastin. Elastin samples were incubated in 2 M glucose solution and were allowed to equilibrate for 4, 7, 14, 21 or 28 days at 37 °C. Equibiaxial tensile tests were performed to study the changes of elastic properties of elastin due to glycation. Significant decreases in tissue dimension were observed after 7 days glucose incubation. Elastin samples treated for 14, 21 or 28 days demonstrate a significant increase in hysteresis in the stress-stretch curves, indicating a greater energy loss due to glucose treatment. Both the longitudinal and the circumferential directions show significant increases in tangent modulus with glucose treatment, however only significant increases are observed after 7 days for the circumferential direction. An eight-chain statistical mechanics based microstructural model was used to study the hyperelastic and orthotropic behavior of the glucose-treated elastin and the material parameters were estimated using a nonlinear least squares method. Material parameters in the model were related to elastin density and fiber orientation, and, hence, the possible microstructural changes in glucose-treated elastin. Estimated material parameters show a general increasing trend in elastin density per unit volume with glucose incubation. The simulation results also indicate that more elastic fibers are aligned in the longitudinal and circumferential directions, rather than in the radial direction. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Evaluation of Prescriptions and Use of Intravenous Pantoprazole in General Wards and Intensive Care Unit of Shahid Sadoughi Hospital in Yazd

    Directory of Open Access Journals (Sweden)

    Seyed-Mojtaba Sohrevardi

    2016-05-01

    Full Text Available Background: Proton pump inhibitors (PPIs are currently the most effective agents for acid related disorders. However, studies show that 25-75% of patients receiving intravenous Pantoprazole had no appropriate justification, indicating high rate of inappropriate prescribing in hospitals. The aim of this study is to examine the appropriate use of intravenous Pantoprazole in accordance with guidelines at Shahid Sadoughi hospital.Methods: From January to April 2015, sample of 100 prescriptions who received Intravenous (IV Pantoprazole were collected with observational and sectional model in Intensive care unit (ICU and general wards of “Shahid Sadoughi” Hospital of Yazd, Iran. Clinical data from patient records are obtained and these data were mapped to establish clinical criteria and appropriate use of Intravenous Pantoprazole.Results: The majority (63% of Intravenous Pantoprazole prescriptions were deemed inappropriate in terms of either indication for use, dose or duration of therapy. 51.5% of the patients were above 55 years old. Endoscopy did not performed in most of the Non UGIB (Non upper gastrointestinal bleeding cases. Most Intravenous Pantoprazole prescriptions were ordered by junior doctors (Intern, and again this group were significantly less likely to prescribe the drug for appropriate reasons when compared with more experienced clinicians.Conclusion: This study suggests that the majority of IV PPI prescriptions in our hospital are inappropriate. Awareness of the result of this article through medical staff could result in more judicious use of intravenous pantoprazole and dose optimization. Physicians and pharmacists can work together to create solutions to inappropriate drug use.

  13. Extended stability of intravenous 0.9% sodium chloride solution after prolonged heating or cooling.

    Science.gov (United States)

    Puertos, Enrique

    2014-03-01

    The primary objective of this study was to evaluate the stability and sterility of an intravenous 0.9% sodium chloride solution that had been cooled or heated for an extended period of time. Fifteen sterile 1 L bags of 0.9% sodium chloride solution were randomly selected for this experiment. Five bags were refrigerated at an average temperature of 5.2°C, 5 bags were heated at an average temperature of 39.2°C, and 5 bags were stored at an average room temperature of 21.8°C to serve as controls. All samples were protected from light and stored for a period of 199 days prior to being assayed and analyzed for microbial and fungal growth. There was no clinically significant difference in the mean sodium values between the refrigerated samples, the heated samples, and the control group. There were no signs of microbial or fungal growth for the duration of the study. A sterile intravenous solution of 0.9% sodium chloride that was heated or cooled remained stable and showed no signs of microbial or fungal growth for a period of 199 days. This finding will allow hospitals and emergency medical technicians to significantly extend the expiration date assigned to these fluids and therefore obviate the need to change out these fluids every 28 days as recommended by the manufacturer.

  14. A new mouse model for renal lesions produced by intravenous injection of diphtheria toxin A-chain expression plasmid

    Directory of Open Access Journals (Sweden)

    Nakamura Shingo

    2004-04-01

    Full Text Available Abstract Background Various animal models of renal failure have been produced and used to investigate mechanisms underlying renal disease and develop therapeutic drugs. Most methods available to produce such models appear to involve subtotal nephrectomy or intravenous administration of antibodies raised against basement membrane of glomeruli. In this study, we developed a novel method to produce mouse models of renal failure by intravenous injection of a plasmid carrying a toxic gene such as diphtheria toxin A-chain (DT-A gene. DT-A is known to kill cells by inhibiting protein synthesis. Methods An expression plasmid carrying the cytomegalovirus enhancer/chicken β-actin promoter linked to a DT-A gene was mixed with lipid (FuGENE™6 and the resulting complexes were intravenously injected into adult male B6C3F1 mice every day for up to 6 days. After final injection, the kidneys of these mice were sampled on day 4 and weeks 3 and 5. Results H-E staining of the kidney specimens sampled on day 4 revealed remarkable alterations in glomerular compartments, as exemplified by mesangial cell proliferation and formation of extensive deposits in glomerular basement membrane. At weeks 3 and 5, gradual recovery of these tissues was observed. These mice exhibited proteinuria and disease resembling sub-acute glomerulonephritis. Conclusions Repeated intravenous injections of DT-A expression plasmid DNA/lipid complex caused temporary abnormalities mainly in glomeruli of mouse kidney. The disease in these mice resembles sub-acute glomerulonephritis. These DT-A gene-incorporated mice will be useful as animal models in the fields of nephrology and regenerative medicine.

  15. Endogenous stem cell proliferation induced by intravenous hedgehog agonist administration after contusion in the adult rat spinal cord.

    Science.gov (United States)

    Bambakidis, Nicholas C; Horn, Eric M; Nakaji, Peter; Theodore, Nicholas; Bless, Elizabeth; Dellovade, Tammy; Ma, Chiyuan; Wang, Xukui; Preul, Mark C; Coons, Stephen W; Spetzler, Robert F; Sonntag, Volker K H

    2009-02-01

    Sonic hedgehog (Shh) is a glycoprotein molecule that upregulates the transcription factor Gli1. The Shh protein plays a critical role in the proliferation of endogenous neural precursor cells when directly injected into the spinal cord after a spinal cord injury in adult rodents. Small-molecule agonists of the hedgehog (Hh) pathway were used in an attempt to reproduce these findings through intravenous administration. The expression of Gli1 was measured in rat spinal cord after the intravenous administration of an Hh agonist. Ten adult rats received a moderate contusion and were treated with either an Hh agonist (10 mg/kg, intravenously) or vehicle (5 rodents per group) 1 hour and 4 days after injury. The rats were killed 5 days postinjury. Tissue samples were immediately placed in fixative. Samples were immunohistochemically stained for neural precursor cells, and these cells were counted. Systemic dosing with an Hh agonist significantly upregulated Gli1 expression in the spinal cord (p < 0.005). After spinal contusion, animals treated with the Hh agonist had significantly more nestin-positive neural precursor cells around the rim of the lesion cavity than in vehicle-treated controls (means +/- SDs, 46.9 +/- 12.9 vs 20.9 +/- 8.3 cells/hpf, respectively, p < 0.005). There was no significant difference in the area of white matter injury between the groups. An intravenous Hh agonist at doses that upregulate spinal cord Gli1 transcription also increases the population of neural precursor cells after spinal cord injury in adult rats. These data support previous findings based on injections of Shh protein directly into the spinal cord.

  16. Efficacy and safety of intravenous fentanyl administered by ambulance personnel

    DEFF Research Database (Denmark)

    Friesgaard, Kristian Dahl; Nikolajsen, Lone; Giebner, Matthias

    2016-01-01

    BACKGROUND: Management of pain in the pre-hospital setting is often inadequate. In 2011, ambulance personnel were authorized to administer intravenous fentanyl in the Central Denmark Region. The aim of this study was to evaluate the efficacy and safety of intravenous fentanyl administered...... by ambulance personnel. METHODS: Pre-hospital medical charts from 2348 adults treated with intravenous fentanyl by ambulance personnel during a 6-month period were reviewed. The primary outcome was the change in pain intensity on a numeric rating scale (NRS) from before fentanyl treatment to hospital arrival...... patients (1.3%) and hypotension observed in 71 patients (3.0%). CONCLUSION: Intravenous fentanyl caused clinically meaningful pain reduction in most patients and was safe in the hands of ambulance personnel. Many patients had moderate to severe pain at hospital arrival. As the protocol allowed higher doses...

  17. Green tea extract does not affect exogenous glucose appearance but reduces insulinemia with glucose ingestion in exercise recovery.

    Science.gov (United States)

    Martin, Brian J; McGlory, Chris; MacInnis, Martin J; Allison, Mary K; Phillips, Stuart M; Gibala, Martin J

    2016-12-01

    We reported that supplementation with green tea extract (GTE) lowered the glycemic response to an oral glucose load following exercise, but via an unknown mechanism (Martin BJ, MacInnis MJ, Gillen JB, Skelly LE, Gibala MJ. Appl Physiol Nutr Metab 41: 1057-1063, 2016. Here we examined the effect of supplementation with GTE on plasma glucose kinetics on ingestion of a glucose beverage during exercise recovery. Eleven healthy, sedentary men (21 ± 2 yr old; body mass index = 23 ± 4 kg/m 2 , peak O 2 uptake = 38 ± 7 ml·kg -1 ·min -1 ; means ± SD) ingested GTE (350 mg) or placebo (PLA) thrice daily for 7 days in a double-blind, crossover design. In the fasted state, a primed constant infusion of [U- 13 C 6 ]glucose was started, and 1 h later, subjects performed a graded exercise test (25 W/3 min) on a cycle ergometer. Immediately postexercise, subjects ingested a 75-g glucose beverage containing 2 g of [6,6- 2 H 2 ]glucose, and blood samples were collected every 10 min for 3 h of recovery. The rate of carbohydrate oxidation was lower during exercise after GTE vs. PLA (1.26 ± 0.34 vs. 1.48 ± 0.51 g/min, P = 0.04). Glucose area under the curve (AUC) was not different between treatments after drink ingestion (GTE = 1,067 ± 133 vs. PLA = 1,052 ± 91 mM/180 min, P = 0.91). Insulin AUC was lower after GTE vs. PLA (5,673 ± 2,153 vs. 7,039 ± 2,588 µIU/180 min, P = 0.05), despite similar rates of glucose appearance (GTE = 0.42 ± 0.16 vs. PLA = 0.43 ± 0.13 g/min, P = 0.74) and disappearance (GTE = 0.43 ± 0.14 vs. PLA = 0.44 ± 0.14 g/min, P = 0.57). We conclude that short-term GTE supplementation did not affect glucose kinetics following ingestion of an oral glucose load postexercise; however, GTE was associated with attenuated insulinemia. These findings suggest GTE lowers the insulin required for a given glucose load during postexercise recovery, which warrants further mechanistic studies in humans. Copyright © 2016 the American Physiological Society.

  18. Effect of the use of a safety intravenous catheters to prevent needle stick injuries

    Directory of Open Access Journals (Sweden)

    Fuladvandi M

    2016-07-01

    Full Text Available The damage caused by sharp objects is one of the most important biological hazards among health care workers. Due to the importance of occupational injury, this study aimed to investigate the efficiency of using safety intravenous catheters with the safety Chamber features in reducing the damage caused by the needle during veni puncture in Afzali pour hospital wards in Kerman. This was a Quasi-experimental study. The sample was consisted of all nurses who worked at Kerman Afzali pour Training hospital during the course of the study.After training was provided to the staff, the available intravenous catheters were distributed among them by hospital medical equipment units. The data were gathered six months before and after the use of safety intravenous catheters, and were analyzed by using SPSS and descriptive statistics tests.The average age at the time of NSI (4.7 ± was 30. People who were in the range of 25-29years oldhad40%injuries.There was a significant correlation between the NSI in the second half of2011 and first half of2012before and after the use of safety angicuts. (p<0.001Considering the results, the use of safety needles is recommended to reduce injury.

  19. Catheter fracture of intravenous ports and its management.

    Science.gov (United States)

    Wu, Ching-Yang; Fu, Jui-Ying; Feng, Po-Hao; Kao, Tsung-Chi; Yu, Sheng-Yueh; Li, Hao-Jui; Ko, Po-Jen; Hsieh, Hung-Chang

    2011-11-01

    Intravenous ports are widely used for oncology patients. However, catheter fractures may lead to the need for re-intervention. We aimed to identify the risk factors associated with catheter fractures. Between January 1 and December 31, 2006, we retrospectively reviewed the clinical data and plain chest films of 1,505 patients implanted with an intravenous port at Chang Gung Memorial Hospital. Different vascular sites were compared using the chi-square or Fisher's exact test for categorical variables, and the t test was used for continuous variables with normal distribution; P port type Arrow French (Fr.) 8.1 (P port and catheter removal is recommended. Female gender, intravenous port implantation via the subclavian route, and the Arrow Fr. 8.1 port were found to be risk factors. Patients with these risk factors should be monitored closely to avoid catheter fractures.

  20. Successful outcome after intravenous gasoline injection.

    Science.gov (United States)

    Domej, Wolfgang; Mitterhammer, Heike; Stauber, Rudolf; Kaufmann, Peter; Smolle, Karl Heinz

    2007-12-01

    Gasoline, ingested intentionally or accidentally, is toxic. The majority of reported cases of gasoline intoxication involve oral ingestion or inhalation. Data are scarce on complications and outcomes following hydrocarbon poisoning by intravenous injection. Following a suicide attempt by intravenous self-injection of 10 ml of gasoline, a 26-year-old medical student was admitted to the intensive care unit (ICU) with hemoptysis, symptoms of acute respiratory failure, chest pain, and severe abdominal cramps. Gas exchange was severely impaired and a chest x-ray indicated chemical pneumonitis. Initial treatment consisted of mechanical ventilation, supportive hyperventilation, administration of nitrogen oxide (NO), and prednisone. Unfortunately, the patient developed multi-organ dysfunction syndrome (MODS) complicated by life-threatening severe vasoplegia within 24 hours after gasoline injection. High doses of vasopressors along with massive amounts of parenteral fluids were necessary. Despite fluid replacement, renal function worsened and required hemofiltration on 5 sequential days. After 12 days of intensive care management, the patient recovered completely and was discharged to a psychiatric care facility. Intravenous gasoline injection causes major injury to the lungs, the organ bearing the first capillary bed encountered. Treatment of gasoline poisoning is symptomatic because no specific antidote is available. Early and aggressive supportive care may be conducive to a favorable outcome with minimal residual pulmonary sequelae.

  1. Smartphone based non-invasive salivary glucose biosensor.

    Science.gov (United States)

    Soni, Anuradha; Jha, Sandeep Kumar

    2017-12-15

    The present work deals with the development of a non-invasive optical glucose biosensor using saliva samples and a smartphone. The sensor was fabricated with a simple methodology by immobilization of Glucose oxidase enzyme along with a pH responsive dye on a filter paper based strip. The strip changes color upon reaction with glucose present in saliva and the color changes were detected using a smartphone camera through RGB profiling. This standalone biosensor showed good sensitivity and low interference while operating within 20 s response time. We used various means for improvements such as the use of slope method instead of differential response; use of a responsive pH indicator and made numerous tweaks in the smartphone app. Calibration with spiked saliva samples with slopes for (R + G + B) pixels revealed an exponentially increasing calibration curve with a linear detection range of 50-540 mg/dL, sensitivity of 0.0012 pixels sec -1 /mg dL -1 and LOD of 24.6 mg/dL. The biosensor was clinically validated on both healthy and diabetic subjects divided into several categories based on sex, age, diabetic status etc. and correlation between blood and salivary glucose has been established for better standardization of the sensor. Correlation of 0.44 was obtained between blood and salivary glucose in healthy individuals whereas it was 0.64 and 0.94 in case of prediabetic and diabetic patients respectively. The developed biosensor has the potential to be used for mass diagnosis of diabetes especially in such areas where people remain prohibited from routine analysis due to high healthcare cost. Apart from that, a smartphone would be the only device the user needs for this measurement, along with a disposable low cost test strip. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. A review of metabolism of labeled glucoses for use in measuring glucose recycling

    International Nuclear Information System (INIS)

    Russell, R.W.; Young, J.W.

    1990-01-01

    The fate of tritium from each carbon of D-glucose and the metabolism of L-glucose and 2-deoxy-D-glucose are known. Differences in metabolism of labeled glucoses can be used to quantify physical and chemical recycling of glucose. Only physical recycling is measured by [1- 3 H]-L-glucose, whereas [U- 14 C]-D-glucose measures total recycling. The difference between [1- 3 H]-L-glucose and [U- 14 C]-D-glucose, therefore, is chemical recycling. Recycling from extracellular binding sites and hepatic glucose 6-phosphate can be measured by difference between [1,2- 3 H]-2-deoxy-D-glucose and [1- 3 H]-L-glucose, and the difference in irreversible loss of the two will measure extrahepatic uptake of D-glucose. Recycling via Cori-alanine cycle plus CO 2 is the difference in irreversible loss measured by using [6- 3 H]-glucose and [U- 14 C]-D-glucose. Recycling via the hexose monophosphate pathway can be determined by difference in irreversible loss between [1- 3 H]-D-glucose and [6- 3 H]-D-glucose. Recycling via CO 2 and glycerol must be measured directly with [U- 14 C]glucose, bicarbonate, and glycerol. Recycling via hepatic glycogen can be estimated by subtracting all other measured chemical recycling from total chemical recycling. This review describes means to quantify glucose recycling in vivo, enabling studies of mechanisms for conservation and utilization of glucose. 54 references

  3. Amperometric glucose biosensor based on layer-by-layer films of microperoxidase-11 and liposome-encapsulated glucose oxidase.

    Science.gov (United States)

    Graça, J S; de Oliveira, R F; de Moraes, M L; Ferreira, M

    2014-04-01

    An important step in several bioanalytical applications is the immobilization of biomolecules. Accordingly, this procedure must be carefully chosen to preserve their biological structure and fully explore their properties. For this purpose, we combined the versatility of the layer-by-layer (LbL) method for the immobilization of biomolecules with the protective behavior of liposome-encapsulated systems to fabricate a novel amperometric glucose biosensor. To obtain the biosensing unit, an LbL film of the H2O2 catalyst polypeptide microperoxidase-11 (MP-11) was assembled onto an indium-tin oxide (ITO) electrode followed by the deposition of a liposome-encapsulated glucose oxidase (GOx) layer. The biosensor response toward glucose detection showed a sensitivity of 0.91±0.09 (μA/cm2)/mM and a limit of detection (LOD) of 8.6±1.1 μM, demonstrating an improved performance compared to similar biosensors with a single phospholipid-liposome or even containing a non-encapsulated GOx layer. Finally, glucose detection was also performed in a zero-lactose milk sample to demonstrate the potential of the biosensor for food analysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Study of potential utility of new radiopharmaceuticals based on technetium-99m labeled derivative of glucose

    Energy Technology Data Exchange (ETDEWEB)

    Zeltchan, R., E-mail: r.zelchan@yandex.ru; Medvedeva, A.; Sinilkin, I.; Chernov, V. [Tomsk Cancer Research Institute, Tomsk, 634050 (Russian Federation); Tomsk Polytechnic University, Tomsk, 634050 (Russian Federation); Stasyuk, E.; Rogov, A.; Il’ina, E.; Larionova, L.; Skuridin, V. [Tomsk Polytechnic University, Tomsk, 634050 (Russian Federation)

    2016-08-02

    Purpose: to study the potential utility of 1-thio-D-glucose labeled with {sup 99m}Tc for cancer imaging in laboratory animals. Materials and method: the study was carried out in cell cultures of normal CHO (Chinese hamster ovary cells CHO) and malignant tissues MCF-7 (human breast adenocarcinoma MCF-7). To evaluate the uptake of {sup 99m}Tc-1-thio-D-glucose in normal and tumor tissue cells, 25 MBq of 1-thio-D-glucose labeled with {sup 99m}Tc was added to the vials with 3 million cells and incubated for 30 min at room temperature. After centrifugation of the vials with cells, the supernatant was removed. The radioactivity in vials with normal and tumor cells was then measured. In addition, the study included 40 mice of C57B1/6j lines with tumor lesion of the right femur. For neoplastic lesions, Lewis lung carcinoma model was used. Following anesthesia, mice were injected intravenously with 25 MBq of {sup 99m}Tc-1-thio-D-glucose. Planar scintigraphy was performed 15 minutes later in a matrix of 512x512 pixels for 5 min. Results: when measuring the radioactivity of normal and malignant cells after incubation with {sup 99m}Tc-1-thio-D-glucose, it was found that the radioactivity of malignant cells was higher than that of normal cells. The mean values of radioactivity levels in normal and malignant cells were 0.3 ± 0.15 MBq and 1.07 ± 0.6 MBq, respectively. All examined animals had increased accumulation of {sup 99m}Tc-1-thio-D-glucose at the tumor site. The accumulation of {sup 99m}Tc-1-thio-D-glucose in the tumor was on average twice as high as compared to the symmetric region. Conclusion: The present study demonstrated that {sup 99m}Tc-1-thio-D-glucose is a prospective radiopharmaceutical for cancer visualization. In addition, high accumulation of {sup 99m}Tc-1-thio-D-glucose in the culture of cancer cells and in tumor tissue of animals demonstrates tumor tropism of the radiopharmaceutical.

  5. Intravenous Transplantation of Mesenchymal Stromal Cells to Enhance Peripheral Nerve Regeneration

    Directory of Open Access Journals (Sweden)

    Stella M. Matthes

    2013-01-01

    Full Text Available Peripheral nerve injury is a common and devastating complication after trauma and can cause irreversible impairment or even complete functional loss of the affected limb. While peripheral nerve repair results in some axonal regeneration and functional recovery, the clinical outcome is not optimal and research continues to optimize functional recovery after nerve repair. Cell transplantation approaches are being used experimentally to enhance regeneration. Intravenous infusion of mesenchymal stromal cells (MSCs into spinal cord injury and stroke was shown to improve functional outcome. However, the repair potential of intravenously transplanted MSCs in peripheral nerve injury has not been addressed yet. Here we describe the impact of intravenously infused MSCs on functional outcome in a peripheral nerve injury model. Rat sciatic nerves were transected followed, by intravenous MSCs transplantation. Footprint analysis was carried out and 21 days after transplantation, the nerves were removed for histology. Labelled MSCs were found in the sciatic nerve lesion site after intravenous injection and regeneration was improved. Intravenously infused MSCs after acute peripheral nerve target the lesion site and survive within the nerve and the MSC treated group showed greater functional improvement. The results of study suggest that nerve repair with cell transplantation could lead to greater functional outcome.

  6. Continued glucose output after re-feeding contributes to glucose intolerance in hyperthyroidism.

    OpenAIRE

    Holness, M J; Sugden, M C

    1987-01-01

    The effects of hyperthyroidism to elicit glucose intolerance after glucose administration were decreased under conditions where hepatic glucose output was suppressed. It is concluded that continued hepatic glucose output contributes to abnormal glucose tolerance in hyperthyroidism.

  7. [Cardiac risk profile in diabetes mellitus and impaired fasting glucose].

    Science.gov (United States)

    Schaan, Beatriz D'Agord; Harzheim, Erno; Gus, Iseu

    2004-08-01

    Mortality of diabetic patients is higher than that of the population at large, and mainly results from cardiovascular diseases. The purpose of the present study was to identify the prevalence of cardiovascular risk factors in subjects with diabetes mellitus (DM) or abnormal fasting glucose (FG) in order to guide health actions. A population-based cross-sectional study was carried out in a representative random cluster sampling of 1,066 adult urban population (> or =20 years) in the state of Rio Grande do Sul between 1999 and 2000. A structured questionnaire on coronary risk factors was applied and sociodemographic characteristics of all adults older than 20 years living in the same dwelling were collected. Subjects were clinically evaluated and blood samples were obtained for measuring total cholesterol and fasting glycemia. Statistical analysis was performed using Stata 7 and a 5% significance level was set. Categorical variables were compared by Pearson's chi-square and continuous variables were compared using Student's t-test or Anova and multivariate analysis, all controlled for the cluster effect. Of 992 subjects, 12.4% were diabetic and 7.4% had impaired fasting glucose. Among the risk factors evaluated, subjects who presented any kind of glucose homeostasis abnormality were at a higher prevalence of obesity (17.8, 29.2 and 35.3% in healthy subjects, impaired fasting glucose and DM respectively, pfasting glucose and DM, respectively, pfasting glucose and DM respectively, p=0.01). Subjects with any kind of glucose homeostasis abnormality represent a group, which preventive individual and population health policies should target since they have higher prevalence of coronary artery disease risk factors.

  8. Pseudo-bi-enzyme glucose sensor: ZnS hollow spheres and glucose oxidase concerted catalysis glucose.

    Science.gov (United States)

    Shuai, Ying; Liu, Changhua; Wang, Jia; Cui, Xiaoyan; Nie, Ling

    2013-06-07

    This work creatively uses peroxidase-like ZnS hollow spheres (ZnS HSs) to cooperate with glucose oxidase (GOx) for glucose determinations. This approach is that the ZnS HSs electrocatalytically oxidate the enzymatically generated H2O2 to O2, and then the O2 circularly participates in the previous glucose oxidation by glucose oxidase. Au nanoparticles (AuNPs) and carbon nanotubes (CNTs) are used as electron transfer and enzyme immobilization matrices, respectively. The biosensor of glucose oxidase-carbon nanotubes-Au nanoparticles-ZnS hollow spheres-gold electrode (GOx-CNT-AuNPs-ZnS HSs-GE) exhibits a rapid response, a low detection limit (10 μM), a wide linear range (20 μM to 7 mM) as well as good anti-interference, long-term longevity and reproducibility.

  9. Human adipose tissue blood flow during prolonged exercise, III. Effect of beta-adrenergic blockade, nicotinic acid and glucose infusion

    DEFF Research Database (Denmark)

    Bülow, J

    1981-01-01

    acid, during acute i.v. beta-adrenergic blockade by propranolol, and during continuous i.v. infusion of glucose. The most pronounced lipid mobilization and utilization during work was seen in the control experiments where ATBF rose 3-fold on average from the initial rest period to the third hour...... of work. No increase in lipolysis and no increase in ATBF were found when lipolysis was blocked by nicotinic acid (0.3 g/h). Propranolol treatment (0.15 mg/kg) reduced lipolysis and nearly abolished the increase in ATBF during exercise. Intravenous administration of glucose (about 0.25 g/min) did......Subcutaneous adipose tissue blood flow (ATBF) was measured in six male subjects by the 133Xe-washout technique during 3-4 h of exercise at a work load corresponding to an oxygen uptake of about 1.71/min. The measurements were done during control conditions, during blockade of lipolysis by nicotinic...

  10. Fabrication of tunable microreactor with enzyme modified magnetic nanoparticles for microfluidic electrochemical detection of glucose

    Energy Technology Data Exchange (ETDEWEB)

    Sheng Jin; Zhang Lei; Lei Jianping [State Key Laboratory of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing 210093 (China); Ju Huangxian, E-mail: hxju@nju.edu.cn [State Key Laboratory of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing 210093 (China)

    2012-01-04

    Highlights: Black-Right-Pointing-Pointer An enzyme microreactor is prepared using an enzyme-nanoparticles packed microchannel. Black-Right-Pointing-Pointer The optimal performance can be obtained by the tunable length of the microreactor. Black-Right-Pointing-Pointer Baseline separation from interferents can be achieved with a microfluidic device. Black-Right-Pointing-Pointer A pretreatment-free determination method for glucose is proposed. - Abstract: A microfluidic device was designed for amperometric determination of glucose by packing enzyme modified magnetic nanoparticles (MNPs) in its microchannel as an enzyme microreactor. Glucose oxidase was covalently attached to the surface of MNPs and localized in the microchannel by the help of an external magnetic field, leading to a tunable packing length. By changing the length of microreactor from 3 to 10 mm, the performance for glucose detection was optimized. The optimal linear range to glucose was from 25 {mu}M to 15 mM with a detection limit of 11 {mu}M at a length of 6 mm. The inter- and intra-day precisions for determination of 1.0 mM glucose were 0.8% and 1.7%, respectively, and the device-to-device reproducibility was 95.6%. The enzyme reactor remained its 81% activity after three-week storage. Due to the advantages of the device and fracture sampling technique, serum samples could be directly sampled through the fracture to achieve baseline separation from ascorbic acid, and proteins in the samples did not interfere with the detection. This work provided a promising way for pretreatment-free determination of glucose with low cost and excellent performance.

  11. Fabrication of tunable microreactor with enzyme modified magnetic nanoparticles for microfluidic electrochemical detection of glucose

    International Nuclear Information System (INIS)

    Sheng Jin; Zhang Lei; Lei Jianping; Ju Huangxian

    2012-01-01

    Highlights: ► An enzyme microreactor is prepared using an enzyme-nanoparticles packed microchannel. ► The optimal performance can be obtained by the tunable length of the microreactor. ► Baseline separation from interferents can be achieved with a microfluidic device. ► A pretreatment-free determination method for glucose is proposed. - Abstract: A microfluidic device was designed for amperometric determination of glucose by packing enzyme modified magnetic nanoparticles (MNPs) in its microchannel as an enzyme microreactor. Glucose oxidase was covalently attached to the surface of MNPs and localized in the microchannel by the help of an external magnetic field, leading to a tunable packing length. By changing the length of microreactor from 3 to 10 mm, the performance for glucose detection was optimized. The optimal linear range to glucose was from 25 μM to 15 mM with a detection limit of 11 μM at a length of 6 mm. The inter- and intra-day precisions for determination of 1.0 mM glucose were 0.8% and 1.7%, respectively, and the device-to-device reproducibility was 95.6%. The enzyme reactor remained its 81% activity after three-week storage. Due to the advantages of the device and fracture sampling technique, serum samples could be directly sampled through the fracture to achieve baseline separation from ascorbic acid, and proteins in the samples did not interfere with the detection. This work provided a promising way for pretreatment-free determination of glucose with low cost and excellent performance.

  12. Glucose-induced insulin resistance of skeletal-muscle glucose transport and uptake

    DEFF Research Database (Denmark)

    Richter, Erik; Hansen, B F; Hansen, S A

    1988-01-01

    in the presence of glucose and insulin. The data indicate that exposure to a moderately increased glucose concentration (12 mM) leads to rapidly developing resistance of skeletal-muscle glucose transport and uptake to maximal insulin stimulation. The effect of glucose is enhanced by simultaneous insulin exposure......, whereas exposure for 5 h to insulin itself does not cause measurable resistance to maximal insulin stimulation.......The ability of glucose and insulin to modify insulin-stimulated glucose transport and uptake was investigated in perfused skeletal muscle. Here we report that perfusion of isolated rat hindlimbs for 5 h with 12 mM-glucose and 20,000 microunits of insulin/ml leads to marked, rapidly developing...

  13. Neuroscience of glucose homeostasis

    NARCIS (Netherlands)

    La Fleur, S E; Fliers, E; Kalsbeek, A

    2014-01-01

    Plasma glucose concentrations are homeostatically regulated and maintained within strict boundaries. Several mechanisms are in place to increase glucose output when glucose levels in the circulation drop as a result of glucose utilization, or to decrease glucose output and increase tissue glucose

  14. Pre-analytical variation in glucose concentration due to atmospheric temperature and clot in blood specimens

    International Nuclear Information System (INIS)

    Butt, T.; Masud, K.; Khan, J.A.; Bhatti, M.S.

    2016-01-01

    Objective: To determine the effect of temperature and contact of clot with serum on laboratory results of glucose concentration in blood. Study Design: Quasi-experimental study. Place and Duration of Study: December 2014 to August 2015 at the laboratory of Shoaib Hospital, Fateh Jang, Attock Pakistan. Material and Methods: Samples were collected for estimation of blood glucose (Random) concentration from patients reporting to the hospital. Blood specimens (n=94) of such volunteers were analyzed for glucose level. Each sample was put up in five tubes. When the blood clotted the serum from tube-1 was analyzed for glucose level within 30 minutes. In tube-2 and tube-3 serum was kept for 24 hours at room temperature and refrigerator temperature respectively before glucose estimation. In tube-4 and tube-5 serum was not separated from clot and kept at room temperature and refrigerator temperature respectively before glucose estimation. The value of tube 1 was taken as reference value for comparison with other parts of the specimen. The equipment used for blood glucose level estimation was semi auto chemistry analyzer (Rayto, China). The kit used for analysis was Glucose - Liquizyme (Germany). Results: The difference between the mean reference value (tube-1) and refrigerated serum without clot (tube-3) was 4.63 mg/100 ml while that of unrefrigerated portion (tube-2) had a difference of 10.68 mg/100 ml. The mean of unrefrigerated (tube-4) and refrigerated (tube-5) portions of serum kept with the clot had difference of 42.05 mg/100 ml and 25.84 mg/100 ml respectively. The fall in the blood glucose level in all (n=94) the samples in the tube number 3 (serum separated and kept at refrigerated temperature) was 4.63 mg/100 ml +- 3.68 (Mean +- SD) and it ranged from 0 to 20 mg/100 ml whereas fall was maximum in the tube number 4 (serum with clotted blood and kept at room temperature) was 42.04 mg/100 ml +- 10.61 (Mean +- SD) and it ranged from 13 to 82 mg/100 ml. The sample in

  15. Use of intravenous immunoglobulin in neonates with haemolytic disease and immune thrombocytopenia

    Directory of Open Access Journals (Sweden)

    Marković-Sovtić Gordana

    2013-01-01

    Full Text Available Background/Aim. Intravenous immunoglobulin is a blood product made of human polyclonal immunoglobulin G. The mode of action of intravenous immunoglobulin is very complex. It is indicated in treatment of neonatal immune thrombocytopenia and haemolytic disease of the newborn. The aim of the study was to present our experience in the use of intravenous immunoglobulin in a group of term neonates. Methods. We analysed all relevant clinical and laboratory data of 23 neonates who recieved intravenous immunoglobulin during their hospitalization in Neonatal Intensive Care Unit of Mother and Child Health Care Institute over a five year period, from 2006. to 2010. Results. There were 11 patients with haemolytic disease of the newborn and 12 neonates with immune thrombocytopenia. All of them recieved 1-2 g/kg intravenous immunoglobulin in the course of their treatment. There was no adverse effects of intravenous immunoglobulin use. The use of intravenous immunoglobulin led to an increase in platelet number in thrombocytopenic patients, whereas in those with haemolytic disease serum bilirubin level decreased significantly, so that some patients whose bilirubin level was very close to the exchange transfusion criterion, avoided this procedure. Conclusion. The use of intravenous immunoglobulin was shown to be an effective treatment in reducing the need for exchange transfusion, duration of phototherapy and the length of hospital stay in neonates with haemolytic disease. When used in treatment of neonatal immune thrombocytopenia, it leads to an increase in the platelet number, thus decreasing the risk of serious complications of thrombocytopenia.

  16. Effect of buspirone: An anxiolytic drug on blood glucose in humans

    OpenAIRE

    Ojha, S. K.; Nandave, M.; Sharma, C.

    2006-01-01

    The present study investigated the effect of an antianxiety drug, buspirone on blood glucose and plasma insulin level concerning the role of 5-HT1A receptors in blood glucose regulation in healthy humans. Twelve healthy male volunteers were administered single oral doses of buspirone (10 mg) or placebo, in a randomized, crossover way, followed by oral glucose load (75 gm in 200 ml) at reported Tmax i.e. the time of peak plasma concentration of the respective administered drug. The blood sampl...

  17. A highly performing electrochemiluminescent biosensor for glucose based on a polyelectrolyte-chitosan modified electrode

    International Nuclear Information System (INIS)

    Dai Hong; Wu Xiaoping; Xu Huifeng; Wang Youmei; Chi Yuwu; Chen Guonan

    2009-01-01

    A highly performing ECL glucose biosensor was developed by immobilizing glucose oxidase (GOD) onto a membrane modified glassy carbon electrode, which was prepared by using poly(diallyldimethylammonium chloride) (PDDA) doped with chitosan. In order to obtain the optimal performance of the ECL biosensor, the composition of modified membranes and a series of measurement conditions were investigated. Under the optimal conditions, this ECL biosensor was able to detect glucose in the range of 0.5-4.0 x 10 4 nM with a detection limit of 0.1 nM (defined as the concentration that could be detected at the signal-to-noise ratio of 3). The relative standard deviation was 0.99% for 5 x 10 -8 mol/L glucose in repetitive measurements in the primary 12 potential cycles. This ECL biosensor offered the effectively improved stability of the electron transfer mediator and exhibited excellent properties for the ultrasensitive and selective determination of glucose with good reproducibility and stability. The present biosensor has also been used to determine the glucose concentrations in real serum samples. The recovery value for the assay of glucose ranged from 96.2 to 107% in the serum samples. The present biosensor displayed both specificity for glucose and retention of signal response even in a complex environment. Therefore, it provided an approach to the sensitive determination of glucose.

  18. Use of intravenous immunoglobulins in clinical practice

    Directory of Open Access Journals (Sweden)

    E.K. Donyush

    2011-01-01

    Full Text Available Immunoglobulins are main component of immune defense; they take part in anti-infectious resistance of organism and regulate processes of different immune reactions. Intravenous immunoglobulins are the most frequently used products made from donor blood plasma. The need in these drugs is steadily increasing during last 15–20 years, and indications are widening due to modern hightechnology methods of production and cleaning. The article presents modern data on formula, mechanisms of action and indications for different groups of intravenous immunoglobulins (standard, hyperimmune, fortified and description of possible adverse events.Key words: immuglobulines, prophylaxis, treatment, unfavorable reaction, children.

  19. Usefulness of modified intravenous analgesia: initial experience in uterine artery embolization for leiomyomata

    International Nuclear Information System (INIS)

    Yang, Seung Boo; Jung, Young Jin; Goo, Dong Erk; Jang, Yun Woo

    2006-01-01

    We wanted to evaluate the usefulness of modified intravenous analgesia for the management of pain during uterine artery embolization for leiomyomata. Between April 2004 and July 2004, 15 patients with symptomatic fibroids underwent uterine artery embolization and pain management. Except the three patients for whom the Visual Analogue Scale (VAS) score was not obtained, twelve patients were included in this study. For pain management, epidural PCA (Patient Controlled Analgesia) was used in two patients, intravenous PCA was used in two patients and modified intravenous analgesia injection was used in eight patients. For all the patients, we used the 2.8 Fr coaxial microcatheter and 500-710 μ m PVA particles for the embolic materials. The protocol of the modified intravenous analgesia injection was as follow, 1) prior to femoral artery puncture, 30 mg of ketorolac tromethamine (Tarasyn)was injected via an intravenous route. 2) At the time that the one side uterine artery embolization was finished, normal saline mixed 150 mg meperidine (Demerol) was administered through the side port of the intravenous line that was used for hydration. 3) Additional ketorolac tromethamine 30 mg was injected after 6 hour. The VAS score and side effects were then checked. After 12 hours, the VAS score was rechecked. If the VAS score was above 4, this was considered as failure of pain management. The VAS scores, complications and side effects for the modified intravenous analgesia injection were compared with that of IV PCA and epidural PCA. The average VAS score of the modified intravenous analgesia injection, intravenous PCA and epidural PCA was 1.4, 1 and 0, respectively; the number of additional intramuscular injections of analgesia was 0.5, 0.5 and 0, respectively. All the patients who underwent epidural PCA had back pain at the puncture site and 1 patient who underwent modified intravenous analgesia injection experienced mild dyspnea, but they easily recovered with such

  20. Usefulness of modified intravenous analgesia: initial experience in uterine artery embolization for leiomyomata

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Seung Boo; Jung, Young Jin [Soonchunhyang University, Gumi Hospital, Gumi (Korea, Republic of); Goo, Dong Erk; Jang, Yun Woo [Soonchunhyang University Hospital, Seoul (Korea, Republic of)

    2006-04-15

    We wanted to evaluate the usefulness of modified intravenous analgesia for the management of pain during uterine artery embolization for leiomyomata. Between April 2004 and July 2004, 15 patients with symptomatic fibroids underwent uterine artery embolization and pain management. Except the three patients for whom the Visual Analogue Scale (VAS) score was not obtained, twelve patients were included in this study. For pain management, epidural PCA (Patient Controlled Analgesia) was used in two patients, intravenous PCA was used in two patients and modified intravenous analgesia injection was used in eight patients. For all the patients, we used the 2.8 Fr coaxial microcatheter and 500-710 {mu} m PVA particles for the embolic materials. The protocol of the modified intravenous analgesia injection was as follow, 1) prior to femoral artery puncture, 30 mg of ketorolac tromethamine (Tarasyn)was injected via an intravenous route. 2) At the time that the one side uterine artery embolization was finished, normal saline mixed 150 mg meperidine (Demerol) was administered through the side port of the intravenous line that was used for hydration. 3) Additional ketorolac tromethamine 30 mg was injected after 6 hour. The VAS score and side effects were then checked. After 12 hours, the VAS score was rechecked. If the VAS score was above 4, this was considered as failure of pain management. The VAS scores, complications and side effects for the modified intravenous analgesia injection were compared with that of IV PCA and epidural PCA. The average VAS score of the modified intravenous analgesia injection, intravenous PCA and epidural PCA was 1.4, 1 and 0, respectively; the number of additional intramuscular injections of analgesia was 0.5, 0.5 and 0, respectively. All the patients who underwent epidural PCA had back pain at the puncture site and 1 patient who underwent modified intravenous analgesia injection experienced mild dyspnea, but they easily recovered with such

  1. Sleep duration and sleep quality are associated differently with alterations of glucose homeostasis

    DEFF Research Database (Denmark)

    Byberg, Stine; Hansen, Anne-Louise Smidt; Christensen, Dirk Lund

    2012-01-01

    Abstract Aims  Studies suggest that inadequate sleep duration and poor sleep quality increase the risk of impaired glucose regulation and diabetes. However, associations with specific markers of glucose homeostasis are less well explained. The objective of this study was to explore possible...... associations of sleep duration and sleep quality with markers of glucose homeostasis and glucose tolerance status in a healthy population-based study sample. Methods  The study comprised 771 participants from the Danish, population-based cross-sectional ‘Health2008’ study. Sleep duration and sleep quality were...... measured by self-report. Markers of glucose homeostasis were derived from a 3-point oral glucose tolerance test and included fasting plasma glucose, 2-h plasma glucose, HbA1c, two measures of insulin sensitivity (the insulin sensitivity index0,120 and homeostasis model assessment of insulin sensitivity...

  2. Breast abscess after intravenous methamphetamine injection into the breast.

    Science.gov (United States)

    Kistler, Amanda; Ajkay, Nicolas

    2018-05-01

    Intravenous drug use is a problem plaguing our society. We present a case of a young female who injected methamphetamine into her mammary vein, resulting in the formation of a breast abscess. This case demonstrates a rare but dangerous complication of intravenous drug use and a possible differential diagnosis in a patient presenting with a breast abscess. © 2017 Wiley Periodicals, Inc.

  3. Glucose allostasis

    DEFF Research Database (Denmark)

    Stumvoll, Michael; Tataranni, P Antonio; Stefan, Norbert

    2003-01-01

    individuals with normal glucose tolerance, normoglycemia can always be maintained by compensatorily increasing AIR in response to decreasing M (and vice versa). This has been mathematically described by the hyperbolic relationship between AIR and M and referred to as glucose homeostasis, with glucose......In many organisms, normoglycemia is achieved by a tight coupling of nutrient-stimulated insulin secretion in the pancreatic beta-cell (acute insulin response [AIR]) and the metabolic action of insulin to stimulate glucose disposal (insulin action [M]). It is widely accepted that in healthy...... concentration assumed to remain constant along the hyperbola. Conceivably, glucose is one of the signals stimulating AIR in response to decreasing M. Hypothetically, as with any normally functioning feed-forward system, AIR should not fully compensate for worsening M, since this would remove the stimulus...

  4. Ventromedial hypothalamic glucose sensing and glucose homeostasis vary throughout the estrous cycle.

    Science.gov (United States)

    Santiago, Ammy M; Clegg, Deborah J; Routh, Vanessa H

    2016-12-01

    17β-Estradiol (17βE) regulates glucose homeostasis in part by centrally mediated mechanisms. In female rodents, the influence of the ovarian cycle on hypoglycemia counterregulation and glucose tolerance is unclear. We found previously that in prepubertal females, 17βE modulates glucose sensing in nonadapting glucose-inhibited (GI) and adapting GI (AdGI) neurons within the ventrolateral portion of the ventromedial nucleus (VL-VMN). Nonadapting GI neurons persistently decrease their activity as glucose increases while AdGI neurons transiently respond to a glucose increase. To begin to understand if endogenous fluctuations in estrogen levels across the estrous cycle impact hypothalamic glucose sensing and glucose homeostasis, we assessed whether hypoglycemia counterregulation and glucose tolerance differed across the phases of the estrous cycle. We hypothesized that the response to insulin-induced hypoglycemia (IIH) and/or glucose tolerance would vary throughout the estrous cycle according to changes in 17βE availability. Moreover, that these changes would correlate with estrous-dependent changes in the glucose sensitivity of VL-VMN glucose-sensing neurons (GSNs). These hypotheses were tested in female mice by measuring the response to IIH, glucose tolerance and the glucose sensitivity of VL-VMN GSNs during each phase of the estrous cycle. Furthermore, a physiological brain concentration of 17βE seen during proestrus was acutely applied to brain slices isolated on the day of diestrous and the response to low glucose in VL-VMN GSNs was assayed. The response to IIH was strongest during diestrous. The response of nonadapting GI and AdGI neurons to a glucose decrease from 2.5 to 0.5mM also peaked during diestrous; an effect which was blunted by the addition of 17βE. In contrast, the glucose sensitivity of the subpopulation of GSNs which are excited by glucose (GE) was not affected by estrous phase or exogenous 17βE application. These data suggest that physiological

  5. Ventromedial hypothalamic glucose sensing and glucose homeostasis vary throughout the estrous cycle

    Science.gov (United States)

    Santiago, Ammy M.; Clegg, Deborah J.; Routh, Vanessa H.

    2016-01-01

    Objective 17β-Estradiol (17βE) regulates glucose homeostasis in part by centrally mediated mechanisms. In female rodents, the influence of the ovarian cycle on hypoglycemia counterregulation and glucose tolerance is unclear. We found previously that in prepubertal females, 17βE modulates glucose sensing in nonadapting glucose-inhibited (GI) and adapting GI (AdGI) neurons within the ventrolateral portion of the ventromedial nucleus (VL-VMN). Nonadapting GI neurons persistently decrease their activity as glucose increases while AdGI neurons transiently respond to a glucose increase. To begin to understand if endogenous fluctuations in estrogen levels across the estrous cycle impact hypothalamic glucose sensing and glucose homeostasis, we assessed whether hypoglycemia counterregulation and glucose tolerance differed across the phases of the estrous cycle. We hypothesized that the response to insulin-induced hypoglycemia (IIH) and/or glucose tolerance would vary throughout the estrous cycle according to changes in 17βE availability. Moreover, that these changes would correlate with estrous-dependent changes in the glucose sensitivity of VL-VMN glucose-sensing neurons (GSNs). Methods These hypotheses were tested in female mice by measuring the response to IIH, glucose tolerance and the glucose sensitivity of VL-VMN GSNs during each phase of the estrous cycle. Furthermore, a physiological brain concentration of 17βE seen during proestrus was acutely applied to brain slices isolated on the day of diestrous and the response to low glucose in VL-VMN GSNs was assayed. Results The response to IIH was strongest during diestrous. The response of nonadapting GI and AdGI neurons to a glucose decrease from 2.5 to 0.5mM also peaked during diestrous; an effect which was blunted by the addition of 17βE. In contrast, the glucose sensitivity of the subpopulation of GSNs which are excited by glucose (GE) was not affected by estrous phase or exogenous 17βE application. Conclusion

  6. Effectiveness of intravenous levetiracetam as an adjunctive treatment in pediatric refractory status epilepticus.

    Science.gov (United States)

    Kim, Jon Soo; Lee, Jeong Ho; Ryu, Hye Won; Lim, Byung Chan; Hwang, Hee; Chae, Jong-Hee; Choi, Jieun; Kim, Ki Joong; Hwang, Yong Seung; Kim, Hunmin

    2014-08-01

    Intravenous levetiracetam (LEV) has been shown to be effective and safe in treating adults with refractory status epilepticus (SE). We sought to investigate the efficacy and safety of intravenous LEV for pediatric patients with refractory SE. We performed a retrospective medical-record review of pediatric patients who were treated with intravenous LEV for refractory SE. Clinical information regarding age, sex, seizure type, and underlying neurological status was collected. We evaluated other anticonvulsants that were used prior to administration of intravenous LEV and assessed loading dose, response to treatment, and any adverse events from intravenous LEV administration. Fourteen patients (8 boys and 6 girls) received intravenous LEV for the treatment of refractory SE. The mean age of the patients was 4.4 ± 5.5 years (range, 4 days to 14.6 years). Ten of the patients were neurologically healthy prior to the refractory SE, and the other 4 had been previously diagnosed with epilepsy. The mean loading dose of intravenous LEV was 26 ± 4.6 mg/kg (range, 20-30 mg/kg). Seizure termination occurred in 6 (43%) of the 14 patients. In particular, 4 (57%) of the 7 patients younger than 2 years showed seizure termination. No immediate adverse events occurred during or after infusions. The current study demonstrated that the adjunctive use of intravenous LEV was effective and well tolerated in pediatric patients with refractory SE, even in patients younger than 2 years. Intravenous LEV should be considered as an effective and safe treatment option for refractory SE in pediatric patients.

  7. Heterotrophic utilization of acetate and glucose in Swartvlei, South Africa

    International Nuclear Information System (INIS)

    Robarts, R.D.

    1979-01-01

    The utilization of dissolved organic compounds in Swartvlei was measured by the addition of single concentrations of 14 C-labelled acetate and glucose to water samples. The results indicated acetate uptake was greatest in the aerobic zone while glucose was predominantly utilized in the anaerobic zone. With the exception of two months, integral glucose uptake was usually greater than the uptake of acetate. In August and September 1971 acetate was indicated as being utilized predominantly by flagellates and in December 1971 by dinoflagellates. During the remainder of the study, bacteria were assumed to be responsible for the uptake of acetate. The extensive weed beds which surround the upper reaches of Swartvlei may be a major source of acetate and glucose in the pelagic water column

  8. Usefulness of MR cholangiopancreatography after intravenous morphine administration

    International Nuclear Information System (INIS)

    Lee, So Jung; Ko, Ji Ho; Cho, Young Duk; Jung, Mi Hee; Yoon, Byung Chull

    2007-01-01

    We wanted to assess the usefulness of MRCP after intravenous morphine administration in the evaluation of the hepatopancreatic pancreatico-biliary ductal system. We studied 15 patients who were suspected of having disease of hepatopancreatic ductal system and they did not have any obstructive lesion on ultrasonography and/or CT. MRCP was acquired before and after morphine administration (0.04 mg/kg, intravenously). Three radiologists scored the quality of the images of the anatomic structures in the hepatopancreatic ductal system. We directly compared the quality of the images obtained with using the two methods and the improvement of the artifacts by pulsatile vascular compression. The MRCP images obtained after intravenous morphine administration were better than those obtained before morphine administration for visualizing the hepatopancreatic ductal system. On direct comparison, the MRCP images obtained after morphine administration were better in 12 cases, equivocal in two cases, and the images before morphine administration were better in only one case. In three patients, MRCP before morphine injection showed signal loss at the duct across the pulsatile hepatic artery. In two of three patients, MRCP after morphine injection showed no signal loss in this ductal area. MRCP after intravenous morphine administration enables physicians to see the hepatopancreatic ductal system significantly better and the artifacts caused by pulsation of the hepatic artery can be avoided

  9. [Efficacy of intravenous phenobarbital treatment for status epilepticus].

    Science.gov (United States)

    Muramoto, Emiko; Mizobuchi, Masahiro; Sumi, Yoshihiro; Sako, Kazuya; Nihira, Atsuko; Takeuchi, Akiko; Nakamura, Hirohiko

    2013-08-01

    Intravenous phenobarbital (IV-PB) therapy was launched in Japan in October 2008. We retrospectively investigated its efficacy and tolerability in patients with status epilepticus. Forty-three consecutive patients received IV-PB for status epilepticus between June 2009 and April 2011. Among them, 39 patients had underlying diseases, which included acute diseases in 19 patients and chronic conditions in 20 patients. Although 18 patients had been taking antiepileptic drugs (AEDs) before the occurrence of status epilepticus, the blood AED concentrations in 8 patients was below the therapeutic levels. Before the administration of IV-PB, 39 patients were treated with intravenous benzodiazepine, 17 patients were treated with intravenous phenytoin, and 15 patients with intravenous infusion of lidocaine. The initial doses of IV-PB ranged from 125 to 1,250 mg (1.9-20.0 mg/kg). Additional doses of IV-PB were required in 12 patients. Seizures were controlled in 35 patients (81%) after IV-PB administration. Cessation of status epilepticus was attained in 24 patients after the initial dose and in 11 patients after additional doses. There were no serious adverse effects, although respiratory suppression was observed in 3 patients and drug eruption was observed in 1 patient. IV-PB is relatively safe and effective for controlling status epilepticus. If the first dose is not effective, additional doses are required up to the recommended maximum dose.

  10. Predictive models of glucose control: roles for glucose-sensing neurones

    Science.gov (United States)

    Kosse, C.; Gonzalez, A.; Burdakov, D.

    2018-01-01

    The brain can be viewed as a sophisticated control module for stabilizing blood glucose. A review of classical behavioural evidence indicates that central circuits add predictive (feedforward/anticipatory) control to the reactive (feedback/compensatory) control by peripheral organs. The brain/cephalic control is constructed and engaged, via associative learning, by sensory cues predicting energy intake or expenditure (e.g. sight, smell, taste, sound). This allows rapidly measurable sensory information (rather than slowly generated internal feedback signals, e.g. digested nutrients) to control food selection, glucose supply for fight-or-flight responses or preparedness for digestion/absorption. Predictive control is therefore useful for preventing large glucose fluctuations. We review emerging roles in predictive control of two classes of widely projecting hypothalamic neurones, orexin/hypocretin (ORX) and melanin-concentrating hormone (MCH) cells. Evidence is cited that ORX neurones (i) are activated by sensory cues (e.g. taste, sound), (ii) drive hepatic production, and muscle uptake, of glucose, via sympathetic nerves, (iii) stimulate wakefulness and exploration via global brain projections and (iv) are glucose-inhibited. MCH neurones are (i) glucose-excited, (ii) innervate learning and reward centres to promote synaptic plasticity, learning and memory and (iii) are critical for learning associations useful for predictive control (e.g. using taste to predict nutrient value of food). This evidence is unified into a model for predictive glucose control. During associative learning, inputs from some glucose-excited neurones may promote connections between the ‘fast’ senses and reward circuits, constructing neural shortcuts for efficient action selection. In turn, glucose-inhibited neurones may engage locomotion/exploration and coordinate the required fuel supply. Feedback inhibition of the latter neurones by glucose would ensure that glucose fluxes they

  11. Predictive models of glucose control: roles for glucose-sensing neurones.

    Science.gov (United States)

    Kosse, C; Gonzalez, A; Burdakov, D

    2015-01-01

    The brain can be viewed as a sophisticated control module for stabilizing blood glucose. A review of classical behavioural evidence indicates that central circuits add predictive (feedforward/anticipatory) control to the reactive (feedback/compensatory) control by peripheral organs. The brain/cephalic control is constructed and engaged, via associative learning, by sensory cues predicting energy intake or expenditure (e.g. sight, smell, taste, sound). This allows rapidly measurable sensory information (rather than slowly generated internal feedback signals, e.g. digested nutrients) to control food selection, glucose supply for fight-or-flight responses or preparedness for digestion/absorption. Predictive control is therefore useful for preventing large glucose fluctuations. We review emerging roles in predictive control of two classes of widely projecting hypothalamic neurones, orexin/hypocretin (ORX) and melanin-concentrating hormone (MCH) cells. Evidence is cited that ORX neurones (i) are activated by sensory cues (e.g. taste, sound), (ii) drive hepatic production, and muscle uptake, of glucose, via sympathetic nerves, (iii) stimulate wakefulness and exploration via global brain projections and (iv) are glucose-inhibited. MCH neurones are (i) glucose-excited, (ii) innervate learning and reward centres to promote synaptic plasticity, learning and memory and (iii) are critical for learning associations useful for predictive control (e.g. using taste to predict nutrient value of food). This evidence is unified into a model for predictive glucose control. During associative learning, inputs from some glucose-excited neurones may promote connections between the 'fast' senses and reward circuits, constructing neural shortcuts for efficient action selection. In turn, glucose-inhibited neurones may engage locomotion/exploration and coordinate the required fuel supply. Feedback inhibition of the latter neurones by glucose would ensure that glucose fluxes they stimulate

  12. Hydrothorax, hydromediastinum and pericardial effusion: a complication of intravenous alimentation.

    Science.gov (United States)

    Damtew, B; Lewandowski, B

    1984-01-01

    Complications secondary to intravenous alimentation are rare but potentially lethal. Massive bilateral pleural effusions and a pericardial effusion developed in a patient receiving prolonged intravenous alimentation. Severe respiratory distress and renal failure ensued. He recovered with appropriate treatment. Images Fig. 1 Fig. 2 Fig. 3 PMID:6428731

  13. Synchrotron-based intravenous cerebral angiography in a small animal model

    International Nuclear Information System (INIS)

    Kelly, Michael E; Schueltke, Elisabeth; Fiedler, Stephan; Nemoz, Christian; Guzman, Raphael; Corde, Stephanie; Esteve, Francois; LeDuc, Geraldine; Juurlink, Bernhard H J; Meguro, Kotoo

    2007-01-01

    K-edge digital subtraction angiography (KEDSA), a recently developed synchrotron-based technique, utilizes monochromatic radiation and allows acquisition of high-quality angiography images after intravenous administration of contrast agent. We tested KEDSA for its suitability for intravenous cerebral angiography in an animal model. Adult male New Zealand rabbits were subjected to either angiography with conventional x-ray equipment or synchrotron-based intravenous KEDSA, using an iodine-based contrast agent. Angiography with conventional x-ray equipment after intra-arterial administration of contrast agent demonstrated the major intracranial vessels but no smaller branches. KEDSA was able to visualize the major intracranial vessels as well as smaller branches in both radiography mode (planar images) and tomography mode. Visualization was achieved with as little as 0.5 ml kg -1 of iodinated contrast material. We were able to obtain excellent visualization of the cerebral vasculature in an animal model using intravenous injection of contrast material, using synchrotron-based KEDSA

  14. Experience in using intravenous thrombolysis in ischemic stroke in Tatarstan

    Directory of Open Access Journals (Sweden)

    Dina Rustemovna Khasanova

    2011-01-01

    Full Text Available The paper describes experience with intravenous thrombolysis used in a few vascular centers of the Republic of Tatarstan in the past 5 years. Intravenous thrombolysis with alteplase (actilise was carried in 300 patients (188 men and 112 women aged 21 to 79 years (mean age 59.8±13.7 years who had ischemic stroke (IS. Significant positive changes (a neurological deficit decrease on the NIHSS score by ≥ 4 points were observed in 67.3% of cases; mortality was 6.7%. Hemorrhagic events as asymptomatic hemorrhagic transformations were found in 19.3% of cases with the neurological disorders being progressive in 4.6%. Recanalization of internal carotid artery occlusion was recorded only in 24.0% of the patients and that of occlusion of the proximal segments of the middle cerebral artery was in 50.1%. Examples of effective intravenous thrombolysis in IS in the carotid and vertebrobasilar beds are given. Whether intravenous thrombolysis can be more extensively used in IS is discussed.

  15. Hemoglobin A1c, fasting plasma glucose, and 2-hour plasma glucose distributions in U.S. population subgroups: NHANES 2005-2010.

    Science.gov (United States)

    Menke, Andy; Rust, Keith F; Savage, Peter J; Cowie, Catherine C

    2014-02-01

    Although mean concentrations of hemoglobin A1c (A1C), fasting plasma glucose, and 2-hour plasma glucose differ by demographics, it is unclear what other characteristics of the distributions may differ, such as the amount of asymmetry of the distribution (skewness) and shift left or right compared with another distribution (shift). Using kernel density estimation, we created smoothed plots of the distributions of fasting plasma glucose (N = 7250), 2-hour plasma glucose (N = 5851), and A1C (N = 16,209) by age, race-ethnicity, and sex in the 2005-2010 National Health and Nutrition Examination Survey, a nationally representative sample of U.S. adults including people with and without diabetes. We tested differences in distributions using cumulative logistic regression. The distributions were generally unimodal and right-skewed. All distributions were shifted higher and more right-skewed for older age groups (P Mexican-Americans (P = .01), whereas the distribution of A1C was shifted higher for non-Hispanic blacks (P rights reserved.

  16. Precision and accuracy of blood glucose measurements using three different instruments.

    Science.gov (United States)

    Nowotny, B; Nowotny, P J; Strassburger, K; Roden, M

    2012-02-01

    Assessment of insulin sensitivity by dynamic metabolic tests such as the hyperinsulinemic euglycemic clamp critically relies on the reproducible and fast measurement of blood glucose concentrations. Although various instruments have been developed over the last decades, little is known as to the accuracy and comparability. We therefore compared the best new instrument with the former gold standard instruments to measure glucose concentrations in metabolic tests. Fasting blood samples of 15 diabetic and 10 healthy subjects were collected into sodium-fluoride tubes, spiked with glucose (0, 2.8, 6.9 and 11.1 mmol/l) and measured either as whole blood (range 3.3-26.3 mmol/l) or following centrifugation as plasma (range 3.9-32.0 mmol/l). Plasma samples were analyzed in the YSI-2300 STAT plus (YSI), EKF Biosen C-Line (EKF) and the reference method, Beckman Glucose analyzer-II (BMG), whole blood samples in EKF instruments with YSI as reference method. The average deviation of the EKF from the reference, BMG, was 3.0 ± 3.5% without any concentration-dependent variability. Glucose measurements by YSI were in good agreement with that by BMG (plasma) and EKF (plasma and whole blood) up to concentrations of 13.13 mmol/l (0.5 ± 3.7%), but deviation increased to -6.2 ± 3.8% at higher concentrations. Precision (n = 6) was ±2.2% (YSI), ±3.9% (EKF) and ±5.2% (BMG). The EKF instrument is comparable regarding accuracy and precision to the reference method BMG and can be used in metabolic tests, while the YSI showed a systematic shift at higher glucose concentrations. Based on these results we decided to replace BMG with EKF instrument in metabolic tests. © 2012 The Authors. Diabetic Medicine © 2012 Diabetes UK.

  17. Hepatitis C seroprevalence among intravenous drug users in Tehran

    Directory of Open Access Journals (Sweden)

    Mohammad Mahdi Mir-Nasseri

    2008-12-01

    Full Text Available

    • BACKGROUND: Hepatitis C (HCV is increasing worldwide including Iran. HCV is more prevalent among intravenous drug abusers (IDU, especially if imprisoned, mostly due to needle sharing. We determined the rate of HCV seropositivity among IDU prisoners and compared it with those of non-prisoners.
    • METHODS: A cross-sectional study was conducted on consenting IDUs inhabiting two prisons and attending three rehabilitation centers in Tehran, Iran. A questionnaire was completed for each subject and 5 ml blood was drawn. The samples were kept at 2-8°C until the sera were separated and stored at -70°C. HCVAb (ELISA was checked by a single technician. Chi-square, Fisher's exact test and multivariate analysis were used where appropriate.
    • RESULTS: Five-hundred and eighteen subjects were enrolled. About 74.5% were prisoners and 89.6% were male. Overall, 59.5% were positive for HCVAb (93.2% males and 6.8% females, P < 0.02. HCV seropositivity was higher among prisoners compared to non-prisoners (78.3% vs. 30.6%, respectively, P < 0.001. Also, it was higher in IUD older than 45 year-old compared to those younger than 30 year-old (77.8% vs.54.2%, respectively, P = 0.002. Multivariate analysis showed significant association of HCV seropositivity with imprisonment (OR: 9.32, 95% CI: 5.60-15.51, sharing syringes (OR: 2.00, 95% CI: 1.26-3.17 and duration of intravenous drug use (OR: 0.86, 95% CI: 0.80-0.92.
    • CONCLUSIONS: HCV is rather common among IDU prisoners. Imprisonment is an independent risk factor for HCV and the infected IDUs going back to the society could be an important source of HCV. Taking effective strategies (education of high risk groups, provision of sterile syringes, identification and treatment of infected IDUs to reduce the risk of this public health problem is needed urgently.
    • KEYWORDS: Hepatitis C, intravenous drug

    • Immobilization of glucose oxidase on graphene and cobalt phthalocyanine composite and its application for the determination of glucose.

      Science.gov (United States)

      Mani, Veerappan; Devasenathipathy, Rajkumar; Chen, Shen-Ming; Huang, Sheng-Tung; Vasantha, V S

      2014-11-01

      We described a simple and facile chemical reduction strategy for the preparation of graphene (GR)-cobalt phthalocyanine (CoPc) composite and explored it for the enzymatic determination of glucose. CoPc is an active mediator and electrocatalysts for the immobilization of GOx and determination of glucose. However, it is not stable on the electrode surface and also suffers from lack of conductivity. Here, we have employed GR as the suitable support to stabilize CoPc through simple chemical reduction method and the resulting composite has been used for the glucose biosensor application. Scanning electron microscopy, X-ray diffraction and Energy-dispersive X-ray spectroscopy studies confirmed the successful formation of composite. Direct electron transfer of glucose oxidase (GOx) was observed with well defined redox peaks at the formal potential of -0.44 V. The amount of electroactive GOx (Г) and electron transfer rate constant (ks) were calculated to be 3.77×10(-10) mol cm(-2) and 3.57 s(-1), respectively. The fabricated amperometric biosensor detects glucose in wide linear concentration range from 10 μM to 14.8 mM with high sensitivity of 5.0 9μA mM(-1) cm(-2). The sensor offered very low detection limit (LOD) of 1.6 μM. In addition, practical feasibility of the sensor has been explored in screen printing carbon electrode with accurate determination of glucose present in human blood serum and urine samples. Furthermore, the sensor exhibited appreciable stability, repeatability and reproducibility results. Copyright © 2014 Elsevier Inc. All rights reserved.

    • Synthesis of high specific activity [1-3H]-D-glucose

      International Nuclear Information System (INIS)

      Saljoughian, M.; Morimoto, Hiromi; Williams, P.G.; Lee, Hakno

      1991-01-01

      Specifically labeled [1- 3 H]-D-glucose has been used for metabolic and mechanistic studies in erythrocytes. In vitro metabolism of the a and b anomers of the tritiated glucose was readily traced by 3 H NMR spectroscopy. Initial studies used labeled glucose obtained by catalytic exchange labeling (at 4.5-9 Ci/mmole, or 15-30% tritiated at the C-1 position), and this necessitated sample glucose concentrations of 2-4 times physiological. The availability of glucose at maximum specific activity (28.7 Ci/mmole, 100% at the C-1 position) would allow the authors to observe metabolic behavior using 1 mM levels of glucose. Accordingly, they have devised a new route for the synthesis of C-1 tritiated glucose, involving the synthesis of 4,6-O-benzylidene-D-gluconolactone followed by reduction with supertritide. Preliminary work with commercial superdeuteride is complete, and chromatographic and NMR analyses are promising. The analogous tritium reactions are currently underway, and experimental results are presented for all stages of investigation. This strategy should be generally applicable to the labeling of many reducing sugars, with the substrates 2-deoxyglucose and maltotriose being of particular interest to their research

    • Reagent-less amperometric glucose biosensor based on a graphite rod electrode layer-by-layer modified with 1,10-phenanthroline-5,6-dione and glucose oxidase.

      Science.gov (United States)

      Kausaite-Minkstimiene, Asta; Simanaityte, Ruta; Ramanaviciene, Almira; Glumbokaite, Laura; Ramanavicius, Arunas

      2017-08-15

      A reagent-less amperometric glucose biosensor operating in not-stirred sample solution was developed. A working electrode of the designed biosensor was based on a graphite rod (GR) electrode, which was modified with 1,10-phenanthroline-5,6-dione (PD) and glucose oxidase (GOx). The PD and the GOx were layer-by-layer adsorbed on the GR electrode surface with subsequent drying followed by chemical cross-linking of the adsorbed GOx with glutaraldehyde (GA). Optimal preparation conditions of the working electrode (GR/PD/GOx) were achieved with 12.6μg and 0.24mg loading amount of PD and GOx, respectively and 25min lasting cross-linking of the GOx with GA. A current response to glucose of the GR/PD/GOx electrode was measured at +200mV potential vs Ag/AgCl reference electrode. Maximum current response was registered when the pH of the buffer solution was 6.0. The registered current response to glucose was linear in the concentration range of 0.1-76mmolL -1 (R 2 =0.9985) and a detection limit was 0.025mmolL -1 . The GR/PD/GOx electrode demonstrated good reproducibility and repeatability with the relative standard deviation of 6.2% and 1.8% (at 4.0mmolL -1 of glucose), respectively, high anti-interference ability to uric and ascorbic acids. It was highly selective to glucose and demonstrated good accuracy in the analysis of human serum samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Glucose oxidase-functionalized fluorescent gold nanoclusters as probes for glucose

    International Nuclear Information System (INIS)

    Xia, Xiaodong; Long, Yunfei; Wang, Jianxiu

    2013-01-01

    Highlights: ► A glucose oxidase/gold nanocluster conjugates formed by etching chemistry. ► Integration of the bioactivities and fluorescence properties within a single unit. ► These conjugates serve as novel fluorescent probe for glucose. -- Abstract: Creation and application of noble metal nanoclusters have received continuous attention. By integrating enzyme activity and fluorescence for potential applications, enzyme-capped metal clusters are more desirable. This work demonstrated a glucose oxidase (an enzyme for glucose)-functionalized gold cluster as probe for glucose. Under physiological conditions, such bioconjugate was successfully prepared by an etching reaction, where tetrakis (hydroxylmethyl) phosphonium-protected gold nanoparticle and thioctic acid-modified glucose oxidase were used as precursor and etchant, respectively. These bioconjugates showed unique fluorescence spectra (λ em max = 650 nm, λ ex max = 507 nm) with an acceptable quantum yield (ca. 7%). Moreover, the conjugated glucose oxidase remained active and catalyzed reaction of glucose and dissolved O 2 to produce H 2 O 2 , which quenched quantitatively the fluorescence of gold clusters and laid a foundation of glucose detection. A linear range of 2.0 × 10 −6 –140 × 10 −6 M and a detection limit of 0.7 × 10 −6 M (S/N = 3) were obtained. Also, another horseradish peroxidase/gold cluster bioconjugate was produced by such general synthesis method. Such enzyme/metal cluster bioconjugates represented a promising class of biosensors for biologically important targets in organelles or cells

  2. Beneficial effect of nitrates on myocardial glucose utilization in unstable angina pectoris

    International Nuclear Information System (INIS)

    Araujo, L.I.; Camici, P.; Spinks, T.; Jones, T.; Maseri, A.

    1987-01-01

    Myocardial uptake of the glucose analog F-18-2-fluoro-2-deoxy-D-glucose (FDG) was assessed by positron emission tomography in 6 normal volunteers, 7 patients with chronic stable angina and 22 patients with unstable angina at rest in fasting conditions. Regional myocardial perfusion was assessed by rubidium-82. The study was repeated a few days later after intravenous infusion of isosorbide dinitrate. FDG uptake was similar in control subjects and patients with stable angina (0.023 +/- 0.032 vs 0.012 +/- 0.008 mol/ml/min, p less than 0.42) but was about 4-fold higher on the average in patients with unstable angina (0.084 +/- 0.047, p less than 0.01). The severity of coronary obstructions in stable and unstable angina patients was similar. The increased uptake involved the whole heart, including areas not distal to critically stenosed vessels; it was not associated with reduced myocardial perfusion and was not related to a recent episode of transient ischemia as assessed by symptoms and by Holter monitoring. After continuous infusion of nitrates, FDG uptake was consistently and significantly reduced toward normal levels both in areas perfused by critically stenosed coronary arteries and by noncritically stenosed vessels

  3. Effects of dietary carbohydrates on glucose and lipid metabolism in golden Syrian hamsters.

    Science.gov (United States)

    Kasim-Karakas, S E; Vriend, H; Almario, R; Chow, L C; Goodman, M N

    1996-08-01

    Frequent coexistence of insulin resistance, central obesity, and hypertriglyceridemia in the same individual suggests an underlying common pathogenesis. Insulin resistance and hypertriglyceridemia can be induced by carbohydrate feeding in rats. Golden Syrian hamsters are believed to be resistant to the metabolic effects of dietary carbohydrates. We investigated the effects of diets containing 60% fructose or sucrose on glucose and lipid metabolism in hamsters, both in the fasting state and during an intravenous glucose tolerance test. Fructose caused obesity (weight after treatment: 131 +/- 7 gm in the control group, 155 +/- 5 gm in the fructose group, 136 +/- 7 gm in sucrose group, p < 0.04). Fructose also reduced glucose disappearance rate (KG: 2.69% +/- 0.39% in the control group, 1.45% +/- 0.18% in the fructose group, p < 0.02). Sucrose caused a marginal decrease in glucose disappearance (KG: 1.93% +/- 0.21%, p = 0.08 vs the control group). Only fructose feeding increased fasting plasma nonesterified fatty acids (0.645 +/- 0.087 mEq/L in the control group, 1.035 +/- 0.083 mEq/L in the fructose group, 0.606 +/- 0.061 mEq/L in the sucrose group, p < 0.002), plasma triglycerides (84 +/- 6 mg/dl in the control group, 270 +/- 65 mg/dl in the fructose group, 94 +/- 16 mg/dl in the sucrose group, p < 0.0002), and liver triglycerides (1.88 +/- 0.38 mg/gm liver weight in the control group, 2.35 =/- 0.24 mg/gm in the fructose group, 1.41 +/- 0.13 mg/gm in the sucrose group, p < 0.04). Previous studies in the rat have suggested that dietary carbohydrates induce insulin resistance by increasing plasma nonesterified fatty acids and triglycerides, which are preferentially used by the muscles. The present report shows that sucrose also can cause some decrease in glucose disappearance in the hamster without causing hypertriglyceridemia or increasing plasma nonesterified fatty acids. Thus other mechanisms may also contribute to the insulin resistance in the hamster. These

  4. Towards a continuous glucose monitoring system using tunable quantum cascade lasers

    Science.gov (United States)

    Haase, Katharina; Müller, Niklas; Petrich, Wolfgang

    2018-02-01

    We present a reagent-free approach for long-term continuous glucose monitoring (cgm) of liquid samples using midinfrared absorption spectroscopy. This method could constitute an alternative to enzymatic glucose sensors in order to manage the widespread disease of Diabetes. In order to acquire spectra of the liquid specimen, we use a spectrally tunable external-cavity (EC-) quantum cascade laser (QCL) as radiation source in combination with a fiber-based in vitro sensor setup. Hereby we achieve a glucose sensitivity in pure glucose solutions of 3 mg/dL (RMSEP). Furthermore, the spectral tunability of the EC-QCL enables us to discriminate glucose from other molecules. We exemplify this by detecting glucose among other saccharides with an accuracy of 8 mg/dL (within other monosaccharides, RMSEVC) and 14 mg/dL (within other mono- and disaccharides, RMSECV). Moreover, we demonstrate a characterization of the significance of each wavenumber for an accurate prediction of glucose among other saccharides using an evolutionary algorithm. We show, that by picking 10 distinct wavenumbers we can achieve comparable accuracies to the use of a complete spectrum.

  5. Assistance algorithm of nursing for amiodarone intravenous infusion

    Directory of Open Access Journals (Sweden)

    Francimar Tinoco de Oliveira

    2014-12-01

    Full Text Available This study aimed at identifying scientific publication on phlebitis caused by amiodarone and proposes a nursing care algorithm for interventions in intravenous amiodarone administration grounded in the Infusion Nursing Society and the Center for Disease Control and Prevention. It is a descriptive study mediated by integrative review in MedLine, LILACS, IBECS, BDENF, Cochrane Library and Scielo bases, published from 2006 to 2013. The sample consisted of nine articles. The evidence pointed the incidence of phlebitis due to the infusion of amiodarone and the need to control this event. The algorithm proposed shows the materials to be used and the procedure of drug administration in order to minimize injury. Besides subsidizing the development of future studies, this algorithm also promotes the incorporation of the best recommendation for the interventionist clinical practice.

  6. Regional cerebral glucose metabolism in patients with alcoholic Korsakoff's syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Kessler, R.M.; Parker, E.S.; Clark, C.M.; Martin, P.R.; George, D.T.; Weingartner, H.; Sokoloff, L.; Ebert, M.H.; Mishkin, M.

    1985-05-01

    Seven alcoholic male subjects diagnosed as having Korsakoff's syndrome and eight age-matched male normal volunteers were studied with /sup 18/F 2-fluoro-2-deoxy-D-glucose (2/sup 18/FDG). All subjects were examined at rest with eyes covered in a quiet, darkened room. Serial plasma samples were obtained following injection of 4 to 5 mCi of 2/sup 18/FDG. Tomographic slices spaced at 10mm axial increments were obtained (in-plane resolution = 1.75 cm, axial resolution = 1.78 cm). Four planes were selected from each subject, and a total of 46 regions of interest were sampled and glucose metabolic rates for each region calculated. The mean glucose metalbolic rate for the 46 regions in the Korsakoff subjects was significantly lower than that in the normal controls (5.17 +- .43 versus 6.6 +- 1.31). A Q-component analysis, which examined each subject's regional rates relative to his mean rate, revealed two distinct patterns in the Korsakoff group. Glucose metabolism was significantly reduced in 37 of the 46 regions sampled. Reduced cerebral glucose metabolism in a nondemented group of subjects has not previously been reported. The reduction in cortical metabolism may be the result of damage to sub-cortical projecting systems. The differing patterns of cerebral metabolism in Korsakoff's syndrome suggests subgroups with differing neuropathology. Regions implicated in memory function, medial temporal, thalamic and medial prefrontal were among the regions reduced in metabolism.

  7. The enteroinsular axis and endocrine pancreatic function in chronic alcohol consumers: evidence for early beta-cell hypofunction.

    Science.gov (United States)

    Patto, R J; Russo, E K; Borges, D R; Neves, M M

    1993-09-01

    Chronic alcohol consumers may have, as judged by functional criteria, exocrine as well as endocrine pancreatic dysfunction, the latter represented by a decreased insulin response to an oral glucose load. To investigate whether this decreased insulin response was due to an ethanol-induced beta-cell dysfunction or to an ethanol-induced dysfunction of the enteroinsular axis, we determined glucose, insulin, and C-peptide plasma concentrations following an oral and an intravenous glucose load in 16 healthy volunteer nonalcohol consumers and in 10 chronic alcohol consumers. In each group, total integrated response for glucose did not significantly change whether glucose was given orally or intravenously, indicating isoglycemic glucose loads. The total integrated response values for insulin in the alcoholic group following both glucose loads as well as C-peptide plasma concentrations were significantly lower than in the control group. Moreover, in both groups the insulin TIR values following the oral glucose load were significantly greater than the values obtained following the intravenous glucose load, indicating an incretin effect. These results indicate that the decreased insulin response observed in alcoholics was not caused by a dysfunction of the enteroinsular axis because it also occurred following an intravenous glucose load, but by an ethanol-induced beta-cell dysfunction because C-peptide and insulin were proportionally decreased in this group.

  8. Comparative study on the results of consecutive oral cholecystography and intravenous cholangiography

    International Nuclear Information System (INIS)

    Lee, Sung Hee; Park, Yang Ok; Yoo, Ho Joon

    1974-01-01

    Since its introduction in 1924, oral cholecystography has been used as a screening method in the diagnosis of the gallbladder disease. Recently, intravenous cholangiography has become a most valuable method in the diagnosis of biliary tract pathology because of its advantage of simultaneous visualization of the gallbladder and bile ducts in a short time. However, opinions vary considerably as to the significance of nonvisualization of the gallbladder with oral cholecystography. In attempt to evaluate how much intravenous cholangiography does contribute to the diagnosis in the cases that the gallbladder cannot be opacified or can only faintly visualized by the oral method, we have made a clinical observation in 168 patients, in whom intravenous cholangiography had been performed within a week following oral cholecystography, at Korea General Hospital during the last three years from January 1969 to December 1971. The results obtained are summarized as follows; 1. The results of oral cholecystography in 168 cases were as follow; well opacification of the gallbladder in 10 cases, faint opacification in 46 cases and nonopacification in 112 cases. 2. In 37.5% (42 cases) of 112 gallbladder not opacified by the oral method, the gallbladder was subsequently opacified by the intravenous method, and 11.6% (14 cases) turned out to be normal when examined by the intravenous method. 3. Further demonstration of abnormalities could be obtained with the aid intravenous cholangiography in 28 cases (16.6%); cholelithiasis in 12 cases and choledocholithiasis in 16 cases. 4. In every cases of 14 patients whose gallbladder were virtually not opacified by both oral and intravenous methods bit the common bile ducts could be opacified by intravenous cholangiography, definite abnormalities were identified in the gallbladder at surgery

  9. The importance of active learning and practice on the students' mastery of pharmacokinetic calculations for the intermittent intravenous infusion dosing of antibiotics

    Directory of Open Access Journals (Sweden)

    Mehvar Reza

    2012-11-01

    Full Text Available Abstract Background Estimation of pharmacokinetic parameters after intermittent intravenous infusion (III of antibiotics, such as aminoglycosides or vancomycin, has traditionally been a difficult subject for students in clinical pharmacology or pharmacokinetic courses. Additionally, samples taken at different intervals during repeated dose therapy require manipulation of sampling times before accurate calculation of the patient-specific pharmacokinetic parameters. The main goal of this study was to evaluate the effectiveness of active learning tools and practice opportunities on the ability of students to estimate pharmacokinetic parameters from the plasma samples obtained at different intervals following intermittent intravenous infusion. Methods An extensive reading note, with examples, and a problem case, based on a patient’s chart data, were created and made available to students before the class session. Students were required to work through the case before attending the class. The class session was devoted to the discussion of the case requiring active participation of the students using a random participation program. After the class, students were given additional opportunities to practice the calculations, using online modules developed by the instructor, before submitting an online assignment. Results The performance of students significantly (P P  Conclusions Despite being a difficult subject, students achieve mastery of pharmacokinetic calculations for the topic of intermittent intravenous infusion when appropriate active learning strategies and practice opportunities are employed.

  10. Effects of dietary energy allowance and decline in dry matter intake during the dry period on responses to glucose and insulin in transition dairy cows.

    Science.gov (United States)

    Salin, S; Vanhatalo, A; Elo, K; Taponen, J; Boston, R C; Kokkonen, T

    2017-07-01

    We assessed whether high energy intake during the early dry period [144% of metabolizable energy (ME) requirements/d] followed by a gradual restriction of energy intake in the close-up dry period (119% of ME/d; HEI) impaired whole-body insulin sensitivity compared with a controlled energy intake (100% of ME/d; CEI) throughout the 6-wk dry period. Multiparous Ayrshire dairy cows (n = 16) were blocked by body weight, body condition score, and expected date of parturition and were used in a randomized complete block design until 10 d after parturition. Cows were fed either HEI or CEI diets based on grass silage during the first 3 wk of the dry period and grass silage supplemented with a commercial concentrate (30% of ME intake) during the final 3 wk of gestation. After calving, all cows were fed grass silage ad libitum and an increasing amount of commercial concentrate (maximum 9 kg at d 10 postpartum). Intravenous glucose tolerance tests (IVGTT) and intravenous insulin challenges were performed -10 ± 5 d (n = 15) and +10 ± 1 d (n = 14) relative to parturition. Following glucose injection, we did not find any treatment effects on glucose and insulin responses. The prepartal nonesterified fatty acid (NEFA) response of the HEI group was blunted, basal NEFA and the decrement of NEFA were smaller, and the area under the response curve (AUC) of NEFA was less negative in HEI cows than in CEI cows. The NEFA response reversed after parturition; the NEFA AUC of the HEI group was more negative than that of the CEI group. We did not find similar responses after insulin injection. Across the treatments, NEFA AUC correlated strongly with the basal NEFA concentration during the IVGTT pre- and postpartum. Calculated and model-based indices characterizing the overall glucose tolerance and β-cell function and the insulin sensitivity were higher after parturition than during the dry period. Consistent with the lower basal insulin, the acute insulin release after the glucose infusion

  11. Glucose oxidase-functionalized fluorescent gold nanoclusters as probes for glucose

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Xiaodong [College of Chemistry and Chemical Engineering, Central South University, Changsha 410083 (China); School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan 411201 (China); Long, Yunfei, E-mail: l_yunfei927@163.com [School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan 411201 (China); Wang, Jianxiu, E-mail: jxiuwang@csu.edu.cn [College of Chemistry and Chemical Engineering, Central South University, Changsha 410083 (China)

    2013-04-15

    Highlights: ► A glucose oxidase/gold nanocluster conjugates formed by etching chemistry. ► Integration of the bioactivities and fluorescence properties within a single unit. ► These conjugates serve as novel fluorescent probe for glucose. -- Abstract: Creation and application of noble metal nanoclusters have received continuous attention. By integrating enzyme activity and fluorescence for potential applications, enzyme-capped metal clusters are more desirable. This work demonstrated a glucose oxidase (an enzyme for glucose)-functionalized gold cluster as probe for glucose. Under physiological conditions, such bioconjugate was successfully prepared by an etching reaction, where tetrakis (hydroxylmethyl) phosphonium-protected gold nanoparticle and thioctic acid-modified glucose oxidase were used as precursor and etchant, respectively. These bioconjugates showed unique fluorescence spectra (λ{sub em} {sub max} = 650 nm, λ{sub ex} {sub max} = 507 nm) with an acceptable quantum yield (ca. 7%). Moreover, the conjugated glucose oxidase remained active and catalyzed reaction of glucose and dissolved O{sub 2} to produce H{sub 2}O{sub 2}, which quenched quantitatively the fluorescence of gold clusters and laid a foundation of glucose detection. A linear range of 2.0 × 10{sup −6}–140 × 10{sup −6} M and a detection limit of 0.7 × 10{sup −6} M (S/N = 3) were obtained. Also, another horseradish peroxidase/gold cluster bioconjugate was produced by such general synthesis method. Such enzyme/metal cluster bioconjugates represented a promising class of biosensors for biologically important targets in organelles or cells.

  12. intravenous infusion of chlorimipramine (anafranil)

    African Journals Online (AJOL)

    the already extensive outpatient facilities at Johannesburg. Hospital as well as the Tara Neuro-Psychiatric Hospital for long-term therapy. Technique of Chlorimipramine Infusion. Initially 1 ampoule of chlorimipramine 25 mg in 250 mg of 5°~ dextrose saline was administered intravenously at the rate of 60 drops per minute.

  13. Human adipose tissue blood flow during prolonged exercise, III. Effect of beta-adrenergic blockade, nicotinic acid and glucose infusion

    DEFF Research Database (Denmark)

    Bülow, J

    1981-01-01

    Subcutaneous adipose tissue blood flow (ATBF) was measured in six male subjects by the 133Xe-washout technique during 3-4 h of exercise at a work load corresponding to an oxygen uptake of about 1.71/min. The measurements were done during control conditions, during blockade of lipolysis by nicotinic...... of work. No increase in lipolysis and no increase in ATBF were found when lipolysis was blocked by nicotinic acid (0.3 g/h). Propranolol treatment (0.15 mg/kg) reduced lipolysis and nearly abolished the increase in ATBF during exercise. Intravenous administration of glucose (about 0.25 g/min) did...

  14. Amperometric glucose biosensor based on glucose oxidase dispersed in multiwalled carbon nanotubes/graphene oxide hybrid biocomposite.

    Science.gov (United States)

    Palanisamy, Selvakumar; Cheemalapati, Srikanth; Chen, Shen-Ming

    2014-01-01

    An amperometric glucose biosensor based on enhanced and fast direct electron transfer (DET) of glucose oxidase (GOx) at enzyme dispersed multiwalled carbon nanotubes/graphene oxide (MWCNT/GO) hybrid biocomposite was developed. The fabricated hybrid biocomposite was characterized by transmission electron microscopy (TEM), Raman and infrared spectroscopy (IR). The TEM image of hybrid biocomposite reveals that a thin layer of GOx was covered on the surface of MWCNT/GO hybrid composite. IR results validate that the hybrid biocomposite was formed through the electrostatic interactions between GOx and MWCNT/GO hybrid composite. Further, MWCNT/GO hybrid composite has also been characterized by TEM and UV-visible spectroscopy. A pair of well-defined redox peak was observed for GOx immobilized at the hybrid biocomposite electrode than that immobilized at the MWCNT modified electrode. The electron transfer rate constant (Ks) of GOx at the hybrid biocomposite was calculated to be 11.22s(-1). The higher Ks value revealed that fast DET of GOx occurred at the electrode surface. Moreover, fabricated biosensor showed a good sensitivity towards glucose oxidation over a linear range 0.05-23.2mM. The limit of detection (LOD) was estimated to be 28μM. The good features of the proposed biosensor could be used for the accurate detection of glucose in the biological samples. © 2013.

  15. Acute effects of light and dark roasted coffee on glucose tolerance

    DEFF Research Database (Denmark)

    Rakvaag, Elin; Dragsted, Lars Ove

    2016-01-01

    PURPOSE: Epidemiological evidence suggests that coffee consumption is associated with a lower risk of type 2 diabetes. Coffee contains caffeine and several other components that may modulate glucose regulation. The chlorogenic acids (CGA) in coffee have been indicated as constituents that may help...... to normalize the acute glucose response after a carbohydrate challenge. The aim of this study was to investigate whether two coffee beverages that differ in CGA content due to different roasting degrees will differentially affect glucose regulation. METHODS: In a controlled crossover trial, 11 healthy fasted...... volunteers consumed 300 mL of either light (LIR) or dark (DAR) roasted coffee, or water, followed 30 min later by a 75-g oral glucose tolerance test (OGTT). Blood samples were drawn at baseline, 30, 60, and 120 min. Differences in glucose and insulin responses and insulin sensitivity index (ISI) were...

  16. GLUCOSE-FRUCTOSE INDEX IN THE GRAPES

    Directory of Open Access Journals (Sweden)

    N. V. Gnilomedova

    2016-01-01

    Full Text Available Results summarize literature and experimental data on the content of glucose and fructose of different varieties in grapes belonging to different botanical species of Vitis. The ratio of glucose and fructose indicator can be used for fermentation control and prevention of under fermentation in the production of dry wines, as well as an identification parameter to assess the authenticity of grape juice and concentratedmust. The object of the study were grapes of red and white winemaking European and autochthonous varieties, belonging to Vitis, as well as varieties of new selection (Aligote, Albilio, Verdelho, Sersial, Rkatsiteli, White Muscat, Cabernet-Sauvignon, Bastardo of Magarach, Kephesiya, Ekim kara, Golubok. Sugar content in grape samples was inthe range of 180-260 g/l. Total hexoses were determined by HPLC method according to a modified methodology developed by the Department of Chemistry and Biochemistry of Wine of "FSBSI "Magarach ". It was established that the value range of the glucose-fructose index in the grapes cultivated in different viniviticultural regions of the world makes 0.74-1.19. It has been revealed that the glucose-fructose index decreases with the ripening of berries. Low index values are characteristic for the grape that ripens at high temperatures and was cultivated in regions with hot climate. High index valuesare characteristic of table grapes and winemaking grape varieties of the species Vitis labrusca, Vitis amurensis and interspecific hybrids. Within the botanical species we canidentify varieties that tend to accumulate higher volumes of either glucose or fructose. These patterns are equally characteristic of white and red grape varieties. The analytical analyzes of the Crimean winemaking grape varieties resulted in the establishment of the glucose-fructose index for the first time, varying within the range of 0.9-1.06.

  17. The accuracy of home glucose meters in hypoglycemia.

    Science.gov (United States)

    Sonmez, Alper; Yilmaz, Zeynep; Uckaya, Gokhan; Kilic, Selim; Tapan, Serkan; Taslipinar, Abdullah; Aydogdu, Aydogan; Yazici, Mahmut; Yilmaz, Mahmut Ilker; Serdar, Muhittin; Erbil, M Kemal; Kutlu, Mustafa

    2010-08-01

    Home glucose meters (HGMs) may not be accurate enough to sense hypoglycemia. We evaluated the accuracy and the capillary and venous comparability of five different HGMs (Optium Xceed [Abbott Diabetes Care, Alameda, CA, USA], Contour TS [Bayer Diabetes Care, Basel, Switzerland], Accu-Chek Go [Roche Ltd., Basel, Switzerland], OneTouch Select [Lifescan, Milpitas, CA, USA], and EZ Smart [Tyson Bioresearch Inc., Chu-Nan, Taiwan]) in an adult population. The insulin hypoglycemia test was performed to 59 subjects (56 males; 23.6 +/- 3.2 years old). Glucose was measured from forearm venous blood and finger capillary samples both before and after regular insulin (0.1 U/kg) was injected. Venous samples were analyzed in the reference laboratory by the hexokinase method. In vitro tests for method comparison and precision analyses were also performed by spiking the glucose-depleted venous blood. All HGMs failed to sense hypoglycemia to some extend. EZ Smart was significantly inferior in critical error Zone D, and OneTouch Select was significantly inferior in the clinically unimportant error Zone B. Accu-Chek Go, Optium Xceed, and Contour TS had similar performances and were significantly better than the other two HGMs according to error grid analysis or International Organization for Standardization criteria. The in vitro tests were consistent with the above clinical data. The capillary and venous consistencies of Accu-Chek Go and OneTouch Select were better than the other HGMs. The present results show that not all the HGMs are accurate enough in low blood glucose levels. The patients and the caregivers should be aware of these restrictions of the HGMs and give more credit to the symptoms of hypoglycemia than the values obtained by the HGMs. Finally, these results indicate that there is a need for the revision of the accuracy standards of HGMs in low blood glucose levels.

  18. Intravenous digital subtraction angiography of transplanted kidney artery

    International Nuclear Information System (INIS)

    Tessier, J.P; Teyssou, H.; Verdier, J.P.; Tison, E.; Meyblum, J.; Marchal, M.

    1986-01-01

    Results of 351 intravenous digital subtraction angiographs (AN) of transplanted kidneys emphasized reliability of this examination for detection of renal artery stenosis. A prospective study of 219 patients (188 interpretable AN) showed significant stenosis of grafted artery in 22% of cases: 17% of the 126 patients with normal blood pressure and 34% of the 62 cases of hypertension. Digital subtraction allows, with a single injection, assessment of renal artery, nephrogram and excretory cavities, but it is not a substitute for conventional intravenous urography 1 to 2 months after grafting [fr

  19. Effect of feeding glucose, fructose, and inulin on blood glucose and insulin concentrations in normal ponies and those predisposed to laminitis.

    Science.gov (United States)

    Borer, K E; Bailey, S R; Menzies-Gow, N J; Harris, P A; Elliott, J

    2012-09-01

    Identification of ponies (Equus caballus) at increased risk of pasture-associated laminitis would aid in the prevention of the disease. Insulin resistance has been associated with laminitis and could be used to identify susceptible individuals. Insulin resistance may be diagnosed by feeding supplementary water-soluble carbohydrate (WSC) and measuring blood glucose and insulin concentrations. The aim of this study was to assess the glycemic and insulinemic responses of 7 normal (NP) and 5 previously laminitic (PLP), mixed breed, native UK ponies fed glucose, fructose, and inulin [1 g/(kg·d) for 3 d] or no supplementary WSC (control) in spring and fall after a 7-d adaptation to a pasture or hay diet. Blood samples were taken for 12 h after feeding on each day, and baseline and peak concentrations and area under the curve (AUC) for glucose and insulin were recorded. Linear mixed models were used for statistical analysis. Differences between PLP and NP groups were most marked after glucose feeding with differences in peak glucose (P = 0.02) and peak insulin (P = 0.016) concentrations. Season and diet adaptation also affected results. Peak concentrations of glucose and insulin occurred 2 to 4 h after WSC feeding. Peak insulin concentration was greater and more variable in fall, particularly in PLP adapted to fall pasture. Baseline glucose and insulin concentrations varied between individuals and with season and diet adaptation but were not greater in PLP than NP. Insulin AUC was greater in PLP than NP after feeding both glucose and fructose (P = 0.017), but there were no differences between PLP and NP in glucose AUC. Glycemic and insulinemic changes were less (P ≤ 0.05) after feeding fructose than glucose, although differences between PLP and NP were still evident. Minimal changes in glucose and insulin concentrations occurred after inulin feeding. Measurement of peak insulin 2 h after feeding of a single dose of glucose (1 g/kg) may be a simple and practical way to

  20. Effects of acute exposure to increased plasma branched-chain amino acid concentrations on insulin-mediated plasma glucose turnover in healthy young subjects.

    Science.gov (United States)

    Everman, Sarah; Mandarino, Lawrence J; Carroll, Chad C; Katsanos, Christos S

    2015-01-01

    Plasma branched-chain amino acids (BCAA) are inversely related to insulin sensitivity of glucose metabolism in humans. However, currently, it is not known whether there is a cause-and-effect relationship between increased plasma BCAA concentrations and decreased insulin sensitivity. To determine the effects of acute exposure to increased plasma BCAA concentrations on insulin-mediated plasma glucose turnover in humans. Ten healthy subjects were randomly assigned to an experiment where insulin was infused at 40 mU/m2/min (40U) during the second half of a 6-hour intravenous infusion of a BCAA mixture (i.e., BCAA; N = 5) to stimulate plasma glucose turnover or under the same conditions without BCAA infusion (Control; N = 5). In a separate experiment, seven healthy subjects were randomly assigned to receive insulin infusion at 80 mU/m2/min (80U) in association with the above BCAA infusion (N = 4) or under the same conditions without BCAA infusion (N = 3). Plasma glucose turnover was measured prior to and during insulin infusion. Insulin infusion completely suppressed the endogenous glucose production (EGP) across all groups. The percent suppression of EGP was not different between Control and BCAA in either the 40U or 80U experiments (P > 0.05). Insulin infusion stimulated whole-body glucose disposal rate (GDR) across all groups. However, the increase (%) in GDR was not different [median (1st quartile - 3rd quartile)] between Control and BCAA in either the 40U ([199 (167-278) vs. 186 (94-308)] or 80 U ([491 (414-548) vs. 478 (409-857)] experiments (P > 0.05). Likewise, insulin stimulated the glucose metabolic clearance in all experiments (P BCAA in either of the experiments (P > 0.05). Short-term exposure of young healthy subjects to increased plasma BCAA concentrations does not alter the insulin sensitivity of glucose metabolism.

  1. Effects of acute exposure to increased plasma branched-chain amino acid concentrations on insulin-mediated plasma glucose turnover in healthy young subjects.

    Directory of Open Access Journals (Sweden)

    Sarah Everman

    Full Text Available Plasma branched-chain amino acids (BCAA are inversely related to insulin sensitivity of glucose metabolism in humans. However, currently, it is not known whether there is a cause-and-effect relationship between increased plasma BCAA concentrations and decreased insulin sensitivity.To determine the effects of acute exposure to increased plasma BCAA concentrations on insulin-mediated plasma glucose turnover in humans.Ten healthy subjects were randomly assigned to an experiment where insulin was infused at 40 mU/m2/min (40U during the second half of a 6-hour intravenous infusion of a BCAA mixture (i.e., BCAA; N = 5 to stimulate plasma glucose turnover or under the same conditions without BCAA infusion (Control; N = 5. In a separate experiment, seven healthy subjects were randomly assigned to receive insulin infusion at 80 mU/m2/min (80U in association with the above BCAA infusion (N = 4 or under the same conditions without BCAA infusion (N = 3. Plasma glucose turnover was measured prior to and during insulin infusion.Insulin infusion completely suppressed the endogenous glucose production (EGP across all groups. The percent suppression of EGP was not different between Control and BCAA in either the 40U or 80U experiments (P > 0.05. Insulin infusion stimulated whole-body glucose disposal rate (GDR across all groups. However, the increase (% in GDR was not different [median (1st quartile - 3rd quartile] between Control and BCAA in either the 40U ([199 (167-278 vs. 186 (94-308] or 80 U ([491 (414-548 vs. 478 (409-857] experiments (P > 0.05. Likewise, insulin stimulated the glucose metabolic clearance in all experiments (P 0.05.Short-term exposure of young healthy subjects to increased plasma BCAA concentrations does not alter the insulin sensitivity of glucose metabolism.

  2. Postarthroscopy analgesia using intraarticular levobupivacaine and intravenous dexketoprofen trometamol.

    Science.gov (United States)

    Sahin, Sevtap Hekimoglu; Memiş, Dilek; Celik, Erkan; Sut, Necdet

    2015-12-01

    The aim of this prospective study was to determine the efficacy of intraarticular levobupivacaine with and without intravenous dexketoprofen trometamol for postarthroscopy analgesia. Sixty patients who underwent arthroscopic knee surgery were randomly assigned to three treatment groups. When the surgical procedure was completed, patients received the following treatments: group I (n = 20) patients received 20 mL intraarticular normal saline and 2 mL intravenous dexketoprofen trometamol (50 mg); group II (n = 20) patients received 20 mL intraarticular 0.5 % levobupivacaine (100 mg) and 2 mL intravenous normal saline; and group III (n = 20) patients received 20 mL intraarticular 0.5 % levobupivacaine (100 mg) and 2 mL intravenous dexketoprofen trometamol (50 mg). The visual analogue scale (VAS) was used, and the total analgesic consumption was assessed at 1, 2, 4, 6, 12, and 24 h post-operatively. The VAS scores at 1, 2, 4, 6, 12, and 24 h post-operatively were significantly increased in group I and group II compared with group III (p dexketoprofen trometamol administration provided better pain relief and less analgesic requirement after arthroscopic knee surgery during the first 24 h than that induced by dexketoprofen alone or levobupivacaine intraarticular alone. II.

  3. Closed-loop controlled noninvasive ultrasonic glucose sensing and insulin delivery

    Science.gov (United States)

    Park, Eun-Joo; Werner, Jacob; Jaiswal, Devina; Smith, Nadine Barrie

    2010-03-01

    To prevent complications in diabetes, the proper management of blood glucose levels is essential. Previously, ultrasonic transdermal methods using a light-weight cymbal transducer array has been studied for noninvasive methods of insulin delivery for Type-1 diabetes and glucose level monitoring. In this study, the ultrasound systems of insulin delivery and glucose sensing have been combined by a feedback controller. This study was designed to show the feasibility of the feedback controlled ultrasound system for the noninvasive glucose control. For perspective human application, in vivo experiments were performed on large animals that have a similar size to humans. Four in vivo experiments were performed using about 200 lbs pigs. The cymbal array of 3×3 pattern has been used for insulin delivery at 30 kHz with the spatial-peak temporal-peak intensity (Isptp) of 100 mW/cm2. For glucose sensing, a 2×2 array was operated at 20 kHz with Isptp = 100 mW/cm2. Based on the glucose level determined by biosensors after the ultrasound exposure, the ultrasound system for the insulin delivery was automatically operated. The glucose level of 115 mg/dl was set as a reference value for operating the insulin delivery system. For comparison, the glucose levels of blood samples collected from the ear vein were measured by a commercial glucose meter. Using the ultrasound system operated by the close-loop, feed-back controller, the glucose levels of four pigs were determined every 20 minutes and continuously controlled for 120 minutes. In comparison to the commercial glucose meter, the glucose levels determined by the biosensor were slightly higher. The results of in vivo experiments indicate the feasibility of the feedback controlled ultrasound system using the cymbal array for noninvasive glucose sensing and insulin delivery. Further studies on the extension of the glucose control will be continued for the effective method of glucose control.

  4. Organizational and technological correlates of nurses' trust in a smart intravenous pump.

    Science.gov (United States)

    Montague, Enid; Asan, Onur; Chiou, Erin

    2013-03-01

    The aim of this study was to understand technology and system characteristics that contribute to nurses' ratings of trust in a smart intravenous pump. Nurses' trust in new technologies can influence how technologies are used. Trust in technology is defined as a person's belief that a technology will not fail them. Potential outcomes of trust in technology are appropriate trust, overtrust, distrust, and mistrust. Trust in technology is also related to several use-specific outcomes, including appropriate use and inappropriate use such as overreliance, disuse or rejection, or misuse. Understanding trust in relation to outcomes can contribute to designs that facilitate appropriate trust in new technologies. A survey was completed by 391 nurses a year after the implementation of a new smart intravenous pump. The survey assessed trust in the intravenous pump and other elements of the sociotechnical system, individual characteristics, technology characteristics, and organizational characteristics. Results show that perceptions of usefulness, safety, ease of use, and usability are related to ratings of trust in smart intravenous pumps. Other work systemfactors such as perception of work environment, age, experience, quality of work, and perception of work performance are also related to ratings of trust. Nurses' trust in smart intravenous pumps is influenced by both characteristics of the technology and the sociotechnical system. Findings from this research have implications for the design of future smart intravenous pumps and health systems. Recommendations for appropriately trustworthy smart intravenous pumps are discussed. Findings also have implications for how trust in health technologies can be measured and conceptualized in complex sociotechnical systems.

  5. Are intravenous injections of contrast media really less nephrotoxic than intra-arterial injections?

    Energy Technology Data Exchange (ETDEWEB)

    Nyman, Ulf [University of Lund, Department of Diagnostic Radiology, Trelleborg (Sweden); Almen, Torsten [Skaane University Hospital, Department of Clinical Sciences/Medical Radiology, University of Lund, Malmoe (Sweden); Jacobsson, Bo [University of Gothenburg and the Sahlgrenska Academy, Department of Diagnostic Radiology, The Queen Silvia Children' s Hospital, Goeteborg (Sweden); Aspelin, Peter [Karolinska Institute and University Hospital, Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Stockholm (Sweden)

    2012-06-15

    We oppose the opinion that the intra-arterial administration of iodine-based contrast media (CM) appears to pose a greater risk of contrast medium-induced nephropathy (CIN) than intravenous administration since (1) in intra-arterial coronary procedures and most other intra-arterial angiographic examinations, CM injections are also intravenous relative to the kidneys, (2) there is a lack of comparative trials studying the risk of CIN between intra-arterial and intravenous procedures with matched risk factors and CM doses, (3) a bias selection of patients with fewer risk factors may explain the seemingly lower rate of CIN after CT in comparison with coronary interventions, (4) the rate of CIN following intra-arterial coronary procedures may also be exaggerated owing to other causes of acute kidney failure, such as haemodynamic instability and microembolisation, (5) roughly the same gram-iodine/GFR ratio ({approx}1:1) as a limit of relatively safe CM doses has preliminarily been found for both intravenous CT and intra-arterial coronary procedures and (6) the substantially higher injected intravenous CM dose rate during CT relative to an intra-arterial coronary procedure might actually pose a higher risk of CIN following CT. Key Points circle Most intra-arterial injections of contrast media are intravenous relative to the kidneys. circle No evidence that intravenous CM injections should be less nephrotoxic than intra-arterial. circle Considerably higher dose rates of CM are used for CT relative to intra-arterial procedures. circle Higher dose rates may pose higher nephrotoxic risk for intravenous based CT studies. (orig.)

  6. Glucose tolerance in two unacculturated Indian tribes of Brazil.

    Science.gov (United States)

    Spielman, R S; Fajans, S S; Neel, J V; Pek, S; Floyd, J C; Oliver, W J

    1982-08-01

    Plasma levels of glucose, insulin, growth hormone, and pancreatic polypeptide in response to a standard oral glucose load were studied in the Yanomama and the Marubo, two relatively unacculturated Amerindian tribes of the Brazilian Amazon. The findings in the two tribes differed significantly from each other and in the degree of deviation from control subjects. The average responses in both tribes differed significantly from those of age- and sex-matched Caucasoid control subjects studied in Ann Arbor, Michigan; however, of the two tribes, the Marubo, the more acculturated group, resembled the controls more closely. Plasma concentrations of glucose and the hormones at three time points (fasting, 1 h, 2 h) were compared by means of a multivariate analysis. When the Marubo were compared with the control subjects, the only highly significant difference was in the plasma glucose concentrations (all three points were higher in the Marubo); however, the Yanomama differed significantly from the control subjects with respect to all four plasma indicators (p less than 0.05). Unlike the Marubo, the Yanomama showed no significant rise in plasma glucose at 1 h and no decrease at 2 h. Neither tribe exhibited the bimodality of the 2 h glucose value characteristic of acculturated Amerindians, such as the Pima, but the samples studied were small.

  7. Comparison of analgesic efficacy of intravenous Paracetamol and intravenous dexketoprofen trometamol in multimodal analgesia after hysterectomy.

    Science.gov (United States)

    Unal, Ciğdem; Cakan, Türkay; Baltaci, Bülent; Başar, Hülya

    2013-10-01

    [corrected] We aimed to evaluate analgesic efficacy, opioid-sparing, and opioid-related adverse effects of intravenous paracetamol and intravenous dexketoprofen trometamol in combination with iv morphine after total abdominal hysterectomy. Sixty American Society of Anesthesiologist Physical Status Classification I-II patients scheduled for total abdominal hysterectomy were enrolled to this double-blinded, randomized, placebo controlled, and prospective study. Patients were divided into three groups as paracetamol, dexketoprofen trometamol, and placebo (0.9% NaCl) due to their post-operative analgesic usage. Intravenous patient controlled analgesia morphine was used as a rescue analgesic in all groups. Pain scores, hemodynamic parameters, morphine consumption, patient satisfaction, and side-effects were evaluated. Visual Analog Scale (VAS) scores were not statistically significantly different among the groups in all evaluation times, but decrease in VAS scores was statistically significant after the evaluation at 12(th) h in all groups. Total morphine consumption (morphine concentration = 0.2 mg/ml) in group paracetamol (72.3 ± 38.0 ml) and dexketoprofen trometamol (69.3 ± 24.1 ml) was significantly lower than group placebo (129.3 ± 22.6 ml) (P dexketoprofen trometamol after surgery and the increase in global satisfaction score was significant only in group placebo. Dexketoprofen trometamol and Paracetamol didn't cause significant change on pain scores, but increased patients' comfort. Although total morphine consumption was significantly decreased by both drugs, the incidence of nausea and vomiting were similar among the groups. According to results of the present study routine addition of dexketoprofen trometamol and paracetamol to patient controlled analgesia morphine after hysterectomies is not recommended.

  8. Predisposing factors for peripheral intravenous puncture failure in children

    OpenAIRE

    Negri,Daniela Cavalcante de; Avelar,Ariane Ferreira Machado; Andreoni,Solange; Pedreira,Mavilde da Luz Gonçalvez

    2012-01-01

    OBJECTIVE: To identify predisposing factors for peripheral intravenous puncture failure in children. METHODS: Cross-sectional cohort study conducted with 335 children in a pediatric ward of a university hospital after approval of the ethics committee. The Wald Chi-squared, Prevalence Ratio (PR) and backward procedure (p≤0.05) tests were applied. RESULTS: Success of peripheral intravenous puncture was obtained in 300 (89.5%) children and failure in 35 (10.4%). The failure rates were sign...

  9. A glucose oxidase-coupled DNAzyme sensor for glucose detection in tears and saliva.

    Science.gov (United States)

    Liu, Chengcheng; Sheng, Yongjie; Sun, Yanhong; Feng, Junkui; Wang, Shijin; Zhang, Jin; Xu, Jiacui; Jiang, Dazhi

    2015-08-15

    Biosensors have been widely investigated and utilized in a variety of fields ranging from environmental monitoring to clinical diagnostics. Glucose biosensors have triggered great interest and have been widely exploited since glucose determination is essential for diabetes diagnosis. In here, we designed a novel dual-enzyme biosensor composed of glucose oxidase (GOx) and pistol-like DNAzyme (PLDz) to detect glucose levels in tears and saliva. First, GOx, as a molecular recognition element, catalyzes the oxidation of glucose forming H2O2; then PLDz recognizes the produced H2O2 as a secondary signal and performs a self-cleavage reaction promoted by Mn(2+), Co(2+) and Cu(2+). Thus, detection of glucose could be realized by monitoring the cleavage rate of PLDz. The slope of the cleavage rate of PLDz versus glucose concentration curve was fitted with a Double Boltzmann equation, with a range of glucose from 100 nM to 10mM and a detection limit of 5 μM. We further applied the GOx-PLDz 1.0 biosensor for glucose detection in tears and saliva, glucose levels in which are 720±81 μM and 405±56 μM respectively. Therefore, the GOx-PLDz 1.0 biosensor is able to determine glucose levels in tears and saliva as a noninvasive glucose biosensor, which is important for diabetic patients with frequent/continuous glucose monitoring requirements. In addition, induction of DNAzyme provides a new approach in the development of glucose biosensors. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Glucose determination in fish plasma by two different moderate methods

    Directory of Open Access Journals (Sweden)

    Jana Bartoňková

    2016-01-01

    Full Text Available Teleost fish include many different species, having a large economic and environmental impact. Glucose is a key source of energy for most vertebrate organisms. Fish as well as mammals maintain a specific level of blood sugar – glycaemia, which is influenced by multiple factors such as hormone production, diet, and temperature. Therefore, it is a useful indicator for scientists who need to check the immediate state of an organism. The most frequently used method of measuring glycaemia in farmed fish is spectrophotometry; however, this method is often inconvenient for field experiments. Here we report that basic spectrophotometry using oxidation of blood beta D-glucose by glucose oxidase (used in laboratory conditions can be easily substituted with portable glucometer measurements, primarily designed for human samples. The possibility of use outside the laboratory and its small sample volume demands make this method very useful. Field studies often require fast sample processing and conditions of measurement are limited. Using the glucometer is a simple and elegant option. We tested 74 blood plasma samples (29 males, 45 females of tench (Tinca tinca both spectrophotometrically and using the human glucometer. Our results show a significant linear correlation (P < 0.001 between both methods. The main contribution of this study consists in comparability and interchangeability of results obtained from both presented methods.

  11. Conversion from intravenous to oral medications: assessment of a computerized intervention for hospitalized patients.

    Science.gov (United States)

    Fischer, Michael A; Solomon, Daniel H; Teich, Jonathan M; Avorn, Jerry

    2003-11-24

    Many hospitalized patients continue to receive intravenous medications longer than necessary. Earlier conversion from the intravenous to the oral route could increase patient safety and comfort, reduce costs, and facilitate earlier discharge from the hospital without compromising clinical care. We examined the effect of a computer-based intervention to prompt physicians to switch appropriate patients from intravenous to oral medications. This study was performed at Brigham and Women's Hospital, an academic tertiary care hospital at which all medications are ordered online. We targeted 5 medications with equal oral and intravenous bioavailability: fluconazole, levofloxacin, metronidazole, ranitidine, and amiodarone. We used the hospital's computerized order entry system to prompt physicians to convert appropriate intravenous medications to the oral route. We measured the total use of the targeted medications via each route in the 4 months before and after the implementation of the intervention. We also measured the rate at which physicians responded to the intervention when prompted. The average intravenous defined daily dose declined by 11.1% (P =.002) from the preintervention to the postintervention period, while the average oral defined daily dose increased by 3.7% (P =.002). Length of stay, case-mix index, and total drug use at the hospital increased during the study period. The average total monthly use of the intravenous preparation of all of the targeted medications declined in the 4 months after the intervention began, compared with the 4 months before. In 35.6% of 1045 orders for which a prompt was generated, the physician either made a conversion from the intravenous to the oral version or canceled the order altogether. Computer-generated reminders can produce a substantial reduction in excessive use of targeted intravenous medications. As online prescribing becomes more common, this approach can be used to reduce excess use of intravenous medications

  12. Integration of a highly ordered gold nanowires array with glucose oxidase for ultra-sensitive glucose detection

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Jiewu [NanoScience and Sensor Technology Research Group, School of Applied Sciences and Engineering, Monash University, Gippsland Campus, Churchill 3842, VIC Australia (Australia); Laboratory of Functional Nanomaterials and Devices, School of Materials Science and Engineering, Hefei University of Technology, Hefei 230009, Anhui (China); Adeloju, Samuel B., E-mail: sam.adeloju@monash.edu [NanoScience and Sensor Technology Research Group, School of Applied Sciences and Engineering, Monash University, Gippsland Campus, Churchill 3842, VIC Australia (Australia); Wu, Yucheng, E-mail: ycwu@hfut.edu.cn [Laboratory of Functional Nanomaterials and Devices, School of Materials Science and Engineering, Hefei University of Technology, Hefei 230009, Anhui (China)

    2014-01-27

    Graphical abstract: -- Highlights: •Successfully synthesised highly-ordered gold nanowires array with an AAO template. •Fabricated an ultra-sensitive glucose nanobiosensor with the gold nanowires array. •Achieved sensitivity as high as 379.0 μA cm{sup −2} mM{sup −1} and detection limit as low as 50 nM. •Achieved excellent anti-interference with aid of Nafion membrane towards UA and AA. •Enabled successful detection and quantification of glucose in human blood serum. -- Abstract: A highly sensitive amperometric nanobiosensor has been developed by integration of glucose oxidase (GO{sub x}) with a gold nanowires array (AuNWA) by cross-linking with a mixture of glutaraldehyde (GLA) and bovine serum albumin (BSA). An initial investigation of the morphology of the synthesized AuNWA by field emission scanning electron microscopy (FESEM) and field emission transmission electron microscopy (FETEM) revealed that the nanowires array was highly ordered with rough surface, and the electrochemical features of the AuNWA with/without modification were also investigated. The integrated AuNWA–BSA–GLA–GO{sub x} nanobiosensor with Nafion membrane gave a very high sensitivity of 298.2 μA cm{sup −2} mM{sup −1} for amperometric detection of glucose, while also achieving a low detection limit of 0.1 μM, and a wide linear range of 5–6000 μM. Furthermore, the nanobiosensor exhibited excellent anti-interference ability towards uric acid (UA) and ascorbic acid (AA) with the aid of Nafion membrane, and the results obtained for the analysis of human blood serum indicated that the device is capable of glucose detection in real samples.

  13. Preliminary evaluation of optical glucose sensing in red cell concentrations using near-infrared diffuse-reflectance spectroscopy

    Science.gov (United States)

    Suzuki, Yusuke; Maruo, Katsuhiko; Zhang, Alice W.; Shimogaki, Kazushige; Ogawa, Hideto; Hirayama, Fumiya

    2012-01-01

    Bacterial contamination of blood products is one of the most frequent infectious complications of transfusion. Since glucose levels in blood supplies decrease as bacteria proliferate, it should be possible to detect the presence of bacterial contamination by measuring the glucose concentrations in the blood components. Hence this study is aimed to serve as a preliminary study for the nondestructive measurement of glucose level in transfusion blood. The glucose concentrations in red blood cell (RBC) samples were predicted using near-infrared diffuse-reflectance spectroscopy in the 1350 to 1850 nm wavelength region. Furthermore, the effects of donor, hematocrit level, and temperature variations among the RBC samples were observed. Results showed that the prediction performance of a dataset which contained samples that differed in all three parameters had a standard error of 29.3 mg/dL. Multiplicative scatter correction (MSC) preprocessing method was also found to be effective in minimizing the variations in scattering patterns created by various sample properties. The results suggest that the diffuse-reflectance spectroscopy may provide another avenue for the detection of bacterial contamination in red cell concentrations (RCC) products.

  14. Efficacy and Tolerability of Intravenous Levetiracetam in Children

    Directory of Open Access Journals (Sweden)

    Jose eAceves

    2013-08-01

    Full Text Available Intractable epilepsy in children poses a serious medical challenge. Acute repetitive seizures and status epilepticus leads to frequent emergency room visits and hospital admissions. Permanent neurological damage can occur if there is delay in treatment. It has been shown that these children continue to remain intractable even after acute seizure management with approved FDA agents. Intravenous levetiracetam, a second-generation anticonvulsant was approved by the FDA in 2006 in patients 16 years and older as an alternative when oral treatment is not an option. It has been shown that oral levetiracetam can be used in the treatment of status epilepticus and acute repetitive seizures. Data have been published showing that intravenous levetiracetam is safe and efficacious, and can be used in an acute inpatient setting. This current review will discuss the recent data about the safety and tolerability of intravenous levetiracetam in children and neonates, and emphasize the need for a larger prospective multicenter trial to prove the efficacy of this agent in acute seizure management.

  15. Plasma glucose level in elective surgical patients administered with 5% dextrose in 0.45% NaCl in comparison with those receiving lactated Ringer's solution.

    Science.gov (United States)

    Saringcarinkul, Ananchanok; Kotrawera, Kriengsak

    2009-09-01

    To determine the effect of dextrose containing solution (5% dextrose in 0.45% NaCl) compared to non-dextrose containing solution (lactated Ringer's solution) on plasma glucose level in elective surgical patients. A prospective randomized double-blind control trial was conducted on 60 patients aged 18-60, with ASA physical status I to II, who were scheduled for elective surgery at Maharaj Nakorn Chiang Mai Hospital, Thailand between October; 2007 and September; 2008. The patients received either lactated Ringer's solution (Group L), or 5% dextrose in 0.45% NaCl (Group D) in the morning of the operation day. Blood glucose levels were determined before intravenous fluid administration (T0), at the beginning (T1), after the 1st hr (T2), and at the end of surgery (T3). Mean duration of preoperative fast was almost 11 hrs in both groups; however, none of the patients had preoperative hypoglycemia. The blood sugar levels were significantly higher in the patients receiving 5% dextrose solution compared to the patients receiving lactated Ringer's solution at the beginning, after the 1st hr and at the end of surgery (p-value = 0.06, 0.018 and 0.036 respectively). There were some patients having hyperglycemia after receiving 5% dextrose in 0.45% NaCl during surgery. However, none of the average plasma glucose values in either group was considered as hyperglycemia. Though they fasted many hours before surgery, no patients were found to have hypoglycemia. The large volume of lactate Ringer's solution had minimal effect on the blood sugar levels compared to the levels in 5% dextrose in 0.45% NaCl group. Therefore, lactate Ringer's solution is probably the alternative choice of intravenous fluid for perioperative maintenance and can be used as replacement in healthy patients undergoing elective surgery.

  16. Adipocyte glucose transport regulation by eicosanoid precursors and inhibitors

    International Nuclear Information System (INIS)

    Lee, H.C.C.

    1987-01-01

    Glucose uptake and free fatty acid release by adipocytes are increased by catecholamines. The mechanism of the stimulatory action of catecholamines on glucose uptake may be via eicosanoid production from release fatty acids. Rats were fed iso-nutrient diets with high or low safflower oil. After one month, 5 rats per diet group were fed diets with aspirin or without aspirin for 2 days. Isolated adipocytes from epididymal fat pads were incubated at 37 0 C, gassed with 95% O 2 -5% CO 2 in KRB buffer with 3% bovine serum albumin and with or without eicosanoid modifiers; a stimulator (10 -5 M norepinephrine, N), or inhibitors (167 μl of antiserum to prostaglandin E (AntiE) per 1600 μl or 23mM Asp), or combinations of these. At 2-, 5-, and 10-min incubation, samples of incubation mixtures were taken to measure 2-deoxy glucose transport using 3 H-2-deoxy glucose, 14 C-inulin, and liquid scintillation counter

  17. Intravenous voriconazole after toxic oral administration

    NARCIS (Netherlands)

    Alffenaar, J.W.C.; Van Assen, S.; De Monchy, J.G.R.; Uges, D.R.A.; Kosterink, J.G.W.; Van Der Werf, T.S.

    In a male patient with rhinocerebral invasive aspergillosis, prolonged high-dosage oral administration of voriconazole led to hepatotoxicity combined with a severe cutaneous reaction while intravenous administration in the same patient did not. High concentrations in the portal blood precipitate

  18. Coping with an exogenous glucose overload: glucose kinetics of rainbow trout during graded swimming.

    Science.gov (United States)

    Choi, Kevin; Weber, Jean-Michel

    2016-03-15

    This study examines how chronically hyperglycemic rainbow trout modulate glucose kinetics in response to graded exercise up to critical swimming speed (Ucrit), with or without exogenous glucose supply. Our goals were 1) to quantify the rates of hepatic glucose production (Ra glucose) and disposal (Rd glucose) during graded swimming, 2) to determine how exogenous glucose affects the changes in glucose fluxes caused by exercise, and 3) to establish whether exogenous glucose modifies Ucrit or the cost of transport. Results show that graded swimming causes no change in Ra and Rd glucose at speeds below 2.5 body lengths per second (BL/s), but that glucose fluxes may be stimulated at the highest speeds. Excellent glucoregulation is also achieved at all exercise intensities. When exogenous glucose is supplied during exercise, trout suppress hepatic production from 16.4 ± 1.6 to 4.1 ± 1.7 μmol·kg(-1)·min(-1) and boost glucose disposal to 40.1 ± 13 μmol·kg(-1)·min(-1). These responses limit the effects of exogenous glucose to a 2.5-fold increase in glycemia, whereas fish showing no modulation of fluxes would reach dangerous levels of 114 mM of blood glucose. Exogenous glucose reduces metabolic rate by 16% and, therefore, causes total cost of transport to decrease accordingly. High glucose availability does not improve Ucrit because the fish are unable to take advantage of this extra fuel during maximal exercise and rely on tissue glycogen instead. In conclusion, trout have a remarkable ability to adjust glucose fluxes that allows them to cope with the cumulative stresses of a glucose overload and graded exercise. Copyright © 2016 the American Physiological Society.

  19. Optical determination of glucose and hydrogen peroxide using a nanocomposite prepared from glucose oxidase and magnetite nanoparticles immobilized on graphene oxide

    International Nuclear Information System (INIS)

    Chang, Qing; Tang, Heqing

    2014-01-01

    Fe 3 O 4 nanoparticles were deposited on sheets of graphene oxide (GO) by a precipitation method, and glucose oxidase (GOx) was then immobilized on this material to produce a GOx/Fe 3 O 4 /GO magnetic nanocomposite containing crosslinked enzyme clusters. The 3-component composite functions as a binary enzyme that was employed in a photometric method for the determination of glucose and hydrogen peroxide where the GOx/Fe 3 O 4 /GO nanoparticles cause the generation of H 2 O 2 which, in turn, oxidize the substrate N,N-diethyl-p-phenylenediamine to form a purple product with an absorption maximum at 550 nm. The absorbance at 550 nm can be correlated to the concentration of glucose and/or hydrogen peroxide. Under optimized conditions, the calibration plot is linear in the 0.5 to 600 μM glucose concentration range, and the detection limit is 0.2 μM. The respective plot for H 2 O 2 ranges from 0.1 to 10 μM, and the detection limit is 0.04 μM. The method was successfully applied to the determination of glucose in human serum samples. The GOx/Fe 3 O 4 /GO nanoparticles are reusable. (author)

  20. Ambient Air Pollutants Have Adverse Effects on Insulin and Glucose Homeostasis in Mexican Americans

    Science.gov (United States)

    Chen, Zhanghua; Salam, Muhammad T.; Toledo-Corral, Claudia; Watanabe, Richard M.; Xiang, Anny H.; Buchanan, Thomas A.; Habre, Rima; Bastain, Theresa M.; Lurmann, Fred; Wilson, John P.; Trigo, Enrique

    2016-01-01

    OBJECTIVE Recent studies suggest that air pollution plays a role in type 2 diabetes (T2D) incidence and mortality. The underlying physiological mechanisms have yet to be established. We hypothesized that air pollution adversely affects insulin sensitivity and secretion and serum lipid levels. RESEARCH DESIGN AND METHODS Participants were selected from BetaGene (n = 1,023), a study of insulin resistance and pancreatic β-cell function in Mexican Americans. All participants underwent DXA and oral and intravenous glucose tolerance tests and completed dietary and physical activity questionnaires. Ambient air pollutant concentrations (NO2, O3, and PM2.5) for short- and long-term periods were assigned by spatial interpolation (maximum interpolation radius of 50 km) of data from air quality monitors. Traffic-related air pollution from freeways (TRAP) was estimated using the dispersion model as NOx. Variance component models were used to analyze individual and multiple air pollutant associations with metabolic traits. RESULTS Short-term (up to 58 days cumulative lagged averages) exposure to PM2.5 was associated with lower insulin sensitivity and HDL-to-LDL cholesterol ratio and higher fasting glucose and insulin, HOMA-IR, total cholesterol, and LDL cholesterol (LDL-C) (all P ≤ 0.036). Annual average PM2.5 was associated with higher fasting glucose, HOMA-IR, and LDL-C (P ≤ 0.043). The effects of short-term PM2.5 exposure on insulin sensitivity were largest among obese participants. No statistically significant associations were found between TRAP and metabolic outcomes. CONCLUSIONS Exposure to ambient air pollutants adversely affects glucose tolerance, insulin sensitivity, and blood lipid concentrations. Our findings suggest that ambient air pollutants may contribute to the pathophysiology in the development of T2D and related sequelae. PMID:26868440

  1. Glucokinase, the pancreatic glucose sensor, is not the gut glucose sensor

    DEFF Research Database (Denmark)

    Murphy, R; Tura, A; Clark, P M

    2008-01-01

    AIMS/HYPOTHESIS: The incretin hormones glucagon-like peptide-1 (GLP-1) and glucose-dependent insulinotrophic peptide (GIP) are released from intestinal endocrine cells in response to luminal glucose. Glucokinase is present in these cells and has been proposed as a glucose sensor. The physiological...... role of glucokinase can be tested using individuals with heterozygous glucokinase gene (GCK) mutations. If glucokinase is the gut glucose sensor, GLP-1 and GIP secretion during a 75 g OGTT would be lower in GCK mutation carriers compared with controls. METHODS: We compared GLP-1 and GIP concentrations...... measured at five time-points during a 75 g OGTT in 49 participants having GCK mutations with those of 28 familial controls. Mathematical modelling of glucose, insulin and C-peptide was used to estimate basal insulin secretion rate (BSR), total insulin secretion (TIS), beta cell glucose sensitivity...

  2. Performance of strip-based glucose meters and cassette-based blood gas analyzer for monitoring glucose levels in a surgical intensive care setting.

    Science.gov (United States)

    Claerhout, Helena; De Prins, Martine; Mesotten, Dieter; Van den Berghe, Greet; Mathieu, Chantal; Van Eldere, Johan; Vanstapel, Florent

    2016-01-01

    We verified the analytical performance of strip-based handheld glucose meters (GM) for prescription use, in a comparative split-sample protocol using blood gas samples from a surgical intensive care unit (ICU). Freestyle Precision Pro (Abbott), StatStrip Connectivity Meter (Nova), ACCU-CHEK Inform II (Roche) were evaluated for recovery/linearity, imprecision/repeatability. The GMs and the ABL90 (Radiometer) blood gas analyzer (BGA) were tested for relative accuracy vs. the comparator hexokinase glucose-6-phosphate-dehydrogenase (HK/G6PDH) assay on a Cobas c702 analyzer (Roche). Recovery of spiked glucose was linear up to 19.3 mmol/L (347 mg/dL) with a slope of 0.91-0.94 for all GMs. Repeatability estimated by pooling duplicate measurements on samples below (n=9), in (n=51) or above (n=80) the 4.2-5.9 mM (74-106 mg/dL) range were for Freestyle Precision Pro: 4.2%, 4.0%, 3.6%; StatStrip Connectivity Meter: 4.0%, 4.3%, 4.5%; and ACCU-CHEK Inform II: 1.4%, 2.5%, 3.5%. GMs were in agreement with the comparator method. The BGA outperformed the GMs, with a MARD of 3.9% compared to 6.5%, 5.8% and 4.4% for the FreeStyle, StatStrip and ACCU-CHEK, respectively. Zero % of the BGA results deviated more than the FDA 10% criterion as compared to 9.4%, 3.7% and 2.2% for the FreeStyle, StatStrip and ACCU-CHEK, respectively. For all GMs, icodextrin did not interfere. Variation in the putative influence factors hematocrit and O2 tension could not explain observed differences with the comparator method. GMs quantified blood glucose in whole blood at about the 10% total error criterion, proposed by the FDA for prescription use.

  3. Starfruit Leaves as Glucose Absorption Inhibitor in Mice’s Small Intestinal Epithelial Cells

    Directory of Open Access Journals (Sweden)

    Rifqi Y Muhammad

    2016-12-01

    Full Text Available Background: Starfruit (Averrhoa carambola leaves contain flavone derivatives that exhibit anti-hyperglycemic effects. This study aims to determine the effect of starfruit leaves in reducing glucose absorption in intestinal epithelial cells of mice. Methods: This study was done by performing perfusion on the small intestines of mice. The mice that were used in this study were divided into four groups. The control group was given glucose solution without infused starfruit leaves whereas, the remaining 3 groups were given 3 mmol (540 mg/dL glucose solution with infused starfruit leaves of varying concentrations; 200, 400, and 600 mg/kg. Samples were collected at 0, 15th, 30th, 45th, and 60th minute. The sample was tested for glucose levels using spectrophotometry. Results: Test of significance showed a significant difference between the control group and the test group with p < 0.05. Conclusions: Starfruit leaves have a reduction effect towards glucose absorption in the small intestines in Wistar strains where the group using 600 mg/kg of infused starfruit leaves have the most significant effect as compared to other groups.

  4. Nonparametric Identification of Glucose-Insulin Process in IDDM Patient with Multi-meal Disturbance

    Science.gov (United States)

    Bhattacharjee, A.; Sutradhar, A.

    2012-12-01

    Modern close loop control for blood glucose level in a diabetic patient necessarily uses an explicit model of the process. A fixed parameter full order or reduced order model does not characterize the inter-patient and intra-patient parameter variability. This paper deals with a frequency domain nonparametric identification of the nonlinear glucose-insulin process in an insulin dependent diabetes mellitus patient that captures the process dynamics in presence of uncertainties and parameter variations. An online frequency domain kernel estimation method has been proposed that uses the input-output data from the 19th order first principle model of the patient in intravenous route. Volterra equations up to second order kernels with extended input vector for a Hammerstein model are solved online by adaptive recursive least square (ARLS) algorithm. The frequency domain kernels are estimated using the harmonic excitation input data sequence from the virtual patient model. A short filter memory length of M = 2 was found sufficient to yield acceptable accuracy with lesser computation time. The nonparametric models are useful for closed loop control, where the frequency domain kernels can be directly used as the transfer function. The validation results show good fit both in frequency and time domain responses with nominal patient as well as with parameter variations.

  5. Adherence of radiopharmaceuticals and labeled cells to intravenous tubing

    International Nuclear Information System (INIS)

    Segall, G.M.; Gurevich, N.; McDougall, I.R.

    1986-01-01

    A survey of 67 nuclear medicine departments revealed no agreement on which radiolabeled agents could be injected through intravenous lines (IVs) and which required direct venipuncture. Labeled cells and several common radiopharmaceuticals were tested for adherence to intravenous tubing. Residual activity remaining in the tubing after an adequate flush was less than 1% of the injected dose in each case. Administration of radiolabeled agents through existing IVs is an acceptable alternative to direct venipuncture in many cases

  6. Modes of Action of Intravenous Immunoglobulin in Bullous Pemphigoid.

    Science.gov (United States)

    Li, Ning; Culton, Donna; Diaz, Luis A; Liu, Zhi

    2018-06-01

    Bullous pemphigoid is an autoantibody-mediated skin blistering disease. Previous studies revealed that intravenous Ig is therapeutic in animal models of bullous pemphigoid by saturating the IgG-protective receptor FcRn, thereby accelerating degradation of pathogenic IgG. Sasaoka et al. demonstrate that the inhibitory effects of intravenous Ig on bullous pemphigoid are also associated with negative modulation of cytokine production by keratinocytes. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  7. Morning cortisol is lower in obese individuals with normal glucose tolerance

    Directory of Open Access Journals (Sweden)

    Praveen EP

    2011-09-01

    Full Text Available Edavan P Praveen1, Jaya Prakash Sahoo1, Bindu Kulshreshtha2, Madan L Khurana3, Nandita Gupta1, Sada Nand Dwivedi3, Guresh Kumar3, Ariachery C Ammini11Department of Endocrinology, All India Institute of Medical Sciences, 2Ram Manohar Lohia Hospital, 3Department of Biostatistics, All India Institute of Medical Sciences, New Delhi, IndiaBackground: There is no consensus on the role of cortisol in the pathogenesis of obesity and metabolic syndrome (MS. This cross-sectional study aimed to analyze the relationship of morning plasma cortisol and adrenocorticotropic hormone (ACTH levels with body mass index (BMI and glucose tolerance.Subjects and methods: The sample frame was the “Offspring of individuals with diabetes study” database. A total of 358 offspring of individuals with type 2 diabetes mellitus (T2DM and 287 individuals without a known family history of T2DM were recruited for the study. Subjects who were ≥10 years of age were selected from the database for analysis. Subjects with T2DM were excluded. All participants underwent a 75 g oral glucose tolerance test (OGTT, and blood samples were collected at 0, 30, 60, and 120 minutes for glucose, insulin and C-peptide. Plasma cortisol, ACTH, and lipid profile were estimated from the fasting sample.Results: Four hundred and ninety-five participants (305 males [62%] and 190 females [38%] were included in the analysis. ACTH and cortisol levels were higher in normal-weight subjects than in overweight/obese subjects. Both ACTH and cortisol increased as fasting plasma glucose increased. Cortisol levels were significantly lower in offspring of T2DM subjects with MS than in offspring of T2DM subjects without MS. When adjusted for BMI, the significance was marginal. In males, cortisol levels were negatively correlated with early insulin secretion during OGTT (insulinogenic index [0–30] and positively with waist circumference and serum high-density lipoprotein cholesterol. In females, fasting

  8. Estimation of endogenous glucose production during hyperinsulinemic-euglycemic glucose clamps. Comparison of unlabeled and labeled exogenous glucose infusates

    International Nuclear Information System (INIS)

    Finegood, D.T.; Bergman, R.N.; Vranic, M.

    1987-01-01

    Tracer methodology has been applied extensively to the estimation of endogenous glucose production (Ra) during euglycemic glucose clamps. The accuracy of this approach has been questioned due to the observation of significantly negative estimates for Ra when insulin levels are high. We performed hyperinsulinemic (300 microU/ml)-euglycemic glucose clamps for 180 min in normal dogs and compared the standard approach, an unlabeled exogenous glucose infusate (cold GINF protocol, n = 12), to a new approach in which a tracer (D-[3- 3 H]glucose) was added to the exogenous glucose used for clamping (hot GINF protocol, n = 10). Plasma glucose, insulin and glucagon concentrations, and glucose infusion rates were similar for the two protocols. Plasma glucose specific activity was 20 +/- 1% of basal (at 120-180 min) in the cold GINF studies, and 44 +/- 3 to 187 +/- 5% of basal in the hot GINF studies. With the one-compartment, fixed pool volume model of Steele, Ra for the cold GINF studies was -2.4 +/- 0.7 mg X min-1 X kg-1 at 25 min and remained significantly negative until 110 min (P less than .05). For the hot GINF studies, Ra was never significantly less than zero (P greater than .05) and was greater than in the cold GINF studies at 20-90 min (P less than .05). There was substantially less between-(78%) and within- (40%) experiment variation for the hot GINF studies compared with the cold GINF studies. An alternate approach (regression method) to the application of the one-compartment model, which allows for a variable and estimable effective distribution volume, yielded Ra estimates that were suppressed 60-100% from basal

  9. Intravenous Laser Therapy in Young Children with Thermal Injuries

    Directory of Open Access Journals (Sweden)

    R. V. Bocharov

    2014-01-01

    Full Text Available Objective: to evaluate the laboratory and clinical effects of combined intravenous laser therapy in young children with thermalinjuries in the acute period of burn disease.Subjects and methods. Forty children whose mean age was 2.67±0.35 years were examined; thermal injuries accounted for 25.05±1.01% of the total body surface area; of them degrees IIIaIIIb was 19.04±0.85%. A comparison group (n=15 received conventional therapy without taking into account and correcting baseline and current hemostasiological disorders. On day 1, a study group (n=25 had programmed anticoagulant therapy and intravenous laser therapy at different radiation frequencies with a Mustang 20002+ laser therapy apparatus (patent for invention No. 2482894 in addition to the conventional therapy. The laser therapy cycle was 6 to 16 sessions. The investigators estimated and compared the following examined parameters: white blood cell count; leukocytic index of intoxication; plasma average mass molecules at a wavelength of 254 nm; toxogenic granularity of neutrophils; wound exudate discharge time; surgical plasty area; and hospitalization time.Results. The positive laboratory and clinical effects of the performed combined intravenous laser therapy in the combined therapy of burn disease in young children were comparatively shown in the study group patients. The significant decrease in the level of an inflammatory response and endogenous intoxication led to a rapider burn wound cleansing, active epithelization, and reduced surgical plasty volumes.Conclusion. Combined intravenous laser therapy signif icantly exerts antiinflammatory and detoxifying effects in young children with 40% thermal injuries in the acute period of burn disease. Abolishing a systemic inflammatory response by combined intravenous laser therapy initiated early regenerative processes in the burn wound and caused reductions in surgical plasty volumes and hospitalization time, which optimizes ther

  10. Differential effects of vildagliptin and glimepiride on glucose fluctuations in patients with type 2 diabetes mellitus assessed using continuous glucose monitoring.

    Science.gov (United States)

    He, Y L; Foteinos, G; Neelakantham, S; Mattapalli, D; Kulmatycki, K; Forst, T; Taylor, A

    2013-12-01

    To assess whether there is a difference in the effects of vildagliptin and glimepiride on glucose fluctuation in patients with type 2 diabetes mellitus (T2DM) using continuous glucose monitoring (CGM). This was an open-label, randomized cross-over study conducted in T2DM patients. A total of 24 patients (age: 58.3 ± 5.56 years, baseline HbA1c: 7.6 ± 0.50%) who were on stable metformin monotherapy (500-3000 mg) were enrolled, and all completed the study. Each patient received two 5-day treatments (vildagliptin 50 mg b.i.d. or glimepiride 2 mg q.d.) in a cross-over manner. Various biomarkers and blood glucose concentrations were measured following breakfast. The 24-h glucose profiles were also measured using the CGM device at baseline and after 5 days of treatment, and fluctuations in glucose levels were estimated from CGM data. Both vildagliptin and glimepiride reduced postprandial glucose levels, based on both CGM data (15% vs. 16%) and measured plasma glucose (13% vs.17%). Vildagliptin showed lower glucose fluctuations than glimepiride as measured by mean amplitude of glycaemic excursions (MAGE, p = 0.1076), standard deviation (s.d., p = 0.1346) of blood glucose rate of change, but did not reach statistical significance attributed to the small sample size. MAGE was reduced by ∼20% with vildagliptin versus glimepiride. Vildagliptin led to statistically significant lowering of the rate of change in the median curve (RCMC) and interquartile range (IQR) of glucose. Treatment with vildagliptin significantly increased the levels of active glucagon-like peptide-1 by 2.36-fold (p ≤ 0.0001) and suppressed glucagon by 8% (p = 0.01), whereas glimepiride significantly increased the levels of insulin and C-peptide by 21% (p = 0.012) and 12% (p = 0.003), respectively. Vildagliptin treatment was associated with less fluctuation of glucose levels than glimepiride treatment as assessed by 24-h CGM device, suggesting vildagliptin may

  11. Screening for hypoglycemia at the bedside in the neonatal intensive care unit (NICU) with the Abbott PCx glucose meter.

    Science.gov (United States)

    Balion, Cynthia; Grey, Vijaylaxmi; Ismaila, Afisi; Blatz, Susan; Seidlitz, Wendy

    2006-11-03

    Point of care (POC) glucose meters are routinely used as a screening tool for hypoglycemia in a neonatal setting. Glucose meters however, lack the same accuracy as laboratory instruments for glucose measurement. In this study we investigated potential reasons for this inaccuracy and established a cut off value for confirmatory testing. In this prospective study, all patients in the neonatal intensive care unit who had a plasma glucose test ordered were eligible to participate. Demographic information, sample collection information (nine variables) and a recent hematocrit value were recorded for each sample. Glucose measurements were taken at the bedside on the glucose meter (RN PCx) as well as in the laboratory on both the glucose meter (LAB PCx) and the laboratory analyzer (PG). Data were analyzed by simple and mixed-effects regression analysis and by analysis of a receiver operator characteristics (ROC) curve. There were 475 samples analyzed from 132 patients. RN PCx values were higher than PG values (mean = 4.9%), while LAB PCx results were lower (mean = -5.2%) than PG values. Only 31% of the difference between RN PCx--PG and 46% of the difference for LAB PCx--PG could be accounted for by the variables tested. The largest proportion of variance between PCx and PG measurements was explained by hematocrit (about 30%) with a greater effect seen at glucose concentrations LAB PCx, respectively). The ROC analysis showed that for detection of all cases of hypoglycemia (PG < 2.6 mmol/L)(PG < 47 mg/dL) the PCx screening cut off value would need to be set at 3.8 mmol/L (68 mg/dL) requiring 20% of all samples to have confirmatory analysis by the laboratory method. The large difference between glucose results obtained by PCx glucose meter compared to the laboratory analyzer can be explained in part by hematocrit and low glucose concentration. These results emphasize that the glucose meter is useful only as a screening device for neonatal hypoglycemia and that a screening

  12. Glucose ingestion stimulates atherothrombotic inflammation in polycystic ovary syndrome

    Science.gov (United States)

    Kirwan, John P.; Rote, Neal S.; Minium, Judi

    2013-01-01

    Women with polycystic ovary syndrome (PCOS) have chronic low-grade inflammation that can increase the risk of atherothrombosis. We performed a cross-sectional study to examine the effect of glucose ingestion on markers of atherothrombotic inflammation in mononuclear cells (MNC) of 16 women with PCOS (8 lean, 8 obese) and 16 weight-matched controls. Activator protein-1 (AP-1) activation and the protein content of early growth response-1 (EGR-1), matrix matalloproteinases-2 (MMP2), and tissue factor (TF) were quantified from MNC obtained from blood drawn fasting and 2 h after glucose ingestion. Plasma MMP9 and C-reactive protein (CRP) were measured from fasting blood samples. Truncal fat was determined by DEXA. Lean women with PCOS exhibited greater AP-1 activation and MMP2 protein content after glucose ingestion and higher plasma MMP9 and CRP levels than lean controls. Obese women with PCOS exhibited greater EGR-1 and TF protein content after glucose ingestion, and plasma CRP levels were even higher compared with lean subjects regardless of PCOS status. Truncal fat correlated with MMP9 and CRP levels and glucose-stimulated increases in AP-1 activation and EGR-1 and TF protein content. Testosterone correlated with glucose-stimulated AP-1 activation, and androstenedione correlated with MMP9 and CRP levels and glucose-stimulated AP-1 activation. Thus, both PCOS and obesity contribute to an atherothrombotic state in which excess abdominal adiposity and hyperandrogenism may be specific risk factors for developing atherothrombosis. PMID:23249695

  13. Use of general practice by intravenous heroin users on a methadone programme.

    OpenAIRE

    Leaver, E J; Elford, J; Morris, J K; Cohen, J

    1992-01-01

    Users of intravenous heroin represent a major challenge for general practice. A study was undertaken in a general practice in central London in 1990 to investigate the use of general practice made by intravenous heroin users who were on a methadone programme. Using information recorded in the patients' notes, 29 intravenous heroin users on a methadone programme were identified; 58 non-drug users (two controls per case) were matched for age, sex and general practitioner. A study of the number ...

  14. Why intravenous moderate sedation should be taught in graduate endodontic programs.

    Science.gov (United States)

    Montagnese, Thomas Anthony

    2012-03-01

    The purpose of this opinion article is to present reasons why intravenous moderate sedation should be taught in graduate endodontic programs. Access to oral health care is an area of much interest and concern, but some patients are unable to get endodontic care because they have special needs. Special needs can refer to patients who fear dentistry itself and other aspects of dental treatment. A variety of phobias and medical, developmental, and physical conditions can make it difficult for some patients to tolerate the endodontic care they need and want. Moderate sedation can help many of these patients. Endodontists in general are not trained to provide intravenous moderate sedation. By incorporating intravenous moderate sedation into endodontic practice, many of these patients can be treated. The first step in achieving this goal is to add intravenous moderate sedation training to graduate endodontic programs. The long-term effect will be to make specialty endodontic care available to more people.

  15. The Effect of Selenium Supplementation on Glucose Homeostasis and the Expression of Genes Related to Glucose Metabolism

    Directory of Open Access Journals (Sweden)

    Ewa Jablonska

    2016-12-01

    Full Text Available The aim of the study was to evaluate the effect of selenium supplementation on the expression of genes associated with glucose metabolism in humans, in order to explain the unclear relationship between selenium and the risk of diabetes. For gene expression analysis we used archival samples of cDNA from 76 non-diabetic subjects supplemented with selenium in the previous study. The supplementation period was six weeks and the daily dose of selenium was 200 µg (as selenium yeast. Blood for mRNA isolation was collected at four time points: before supplementation, after two and four weeks of supplementation, and after four weeks of washout. The analysis included 15 genes encoding selected proteins involved in insulin signaling and glucose metabolism. In addition, HbA1c and fasting plasma glucose were measured at three and four time points, respectively. Selenium supplementation was associated with a significantly decreased level of HbA1c but not fasting plasma glucose (FPG and significant down-regulation of seven genes: INSR, ADIPOR1, LDHA, PDHA, PDHB, MYC, and HIF1AN. These results suggest that selenium may affect glycemic control at different levels of regulation, linked to insulin signaling, glycolysis, and pyruvate metabolism. Further research is needed to investigate mechanisms of such transcriptional regulation and its potential implication in direct metabolic effects.

  16. Potential intravenous drug interactions in intensive care

    Directory of Open Access Journals (Sweden)

    Maiara Benevides Moreira

    Full Text Available Abstract OBJECTIVE To analyze potential intravenous drug interactions, and their level of severity associated with the administration of these drugs based on the prescriptions of an intensive care unit. METHOD Quantitative study, with aretrospective exploratory design, and descriptive statistical analysis of the ICU prescriptions of a teaching hospital from March to June 2014. RESULTS The sample consisted of 319 prescriptions and subsamples of 50 prescriptions. The mean number of drugs per patient was 9.3 records, and a higher probability of drug interaction inherent to polypharmacy was evidenced. The study identified severe drug interactions, such as concomitant administration of Tramadol with selective serotonin reuptake inhibitor drugs (e.g., Metoclopramide and Fluconazole, increasing the risk of seizures due to their epileptogenic actions, as well as the simultaneous use of Ranitidine-Fentanyl®, which can lead to respiratory depression. CONCLUSION A previous mapping of prescriptions enables the characterization of the drug therapy, contributing to prevent potential drug interactions and their clinical consequences.

  17. Responses of plasma glucose and nonesterified fatty acids to intravenous insulin tolerance tests in dairy cows during a 670-day lactation.

    Science.gov (United States)

    Marett, L C; Auldist, M J; Wales, W J; Macmillan, K L; Dunshea, F R; Leury, B J

    2017-04-01

    The metabolic response of dairy cows undergoing an extended lactation to an insulin tolerance test (ITT) was investigated. Twelve multiparous Holstein-Friesian cows that calved in late winter in a pasture-based system were managed for a 670-d lactation by delaying rebreeding. Four 5-wk experimental periods commenced at approximately 73, 217, 422, and 520 d in milk (DIM). Cows were offered a diet of perennial ryegrass (73 and 422 DIM) or pasture hay and silage (217 and 520 DIM) supplemented with 1 kg dry matter (DM) of grain (control; CON) or 6 kg DM of grain (GRN). Daily energy intake was approximately 160 and 215 MJ of metabolizable energy/cow for CON and GRN, respectively. At all other times, cows were managed as a single herd and grazed pasture supplemented with grain to an estimated daily intake of 180 MJ of metabolizable energy/cow. Cows were fitted with a jugular catheter during the final week of each experimental period. An ITT using 0.12 IU of insulin/kg of body weight (BW) was conducted on each cow at approximately 100, 250, 460, and 560 DIM. Cows in the GRN treatment had greater milk yield, milk solids yield, and BW than cows in the CON treatment. Within treatment, individual cow responses to the ITT were highly variable. Plasma glucose and nonesterified fatty acid (NEFA) concentrations declined at all stages of lactation. The clearance rate of plasma glucose was slower before 300 DIM than after 300 DIM, which indicates greater inhibition of hepatic glucose synthesis and uptake of glucose by insulin-dependent tissues later in the lactation. The clearance rate, area under the curve, and recovery of plasma NEFA were greatest at 100 DIM, indicating greater responsiveness to the antilipolytic effect of insulin in early lactation, but also greater lipolytic responsiveness. The variation in response to the ITT was mostly a result of DIM rather than diet. However, the plasma NEFA response showed interactions between diet and DIM, indicating that energy intake

  18. The priming effect of glucose in soil sterilized by γ-radiation and reinoculated with Cellulomonas sp

    International Nuclear Information System (INIS)

    Kunc, F.

    1980-01-01

    The mineralization of native organic matter and U- 14 C-glucose was studied by measuring the formation of CO 2 and its radioactivity in chernozem soil samples presterilized by γ-radiation and inoculated with a washed suspension of Cellulomonas sp. cells. The introduced bacteria mineralized the soil organic component to a higher extent in variants enriched with glucose. This so-called priming effect of glucose was observed also in the presence of chloramphenicol inhibiting the growth of the bacteria. An increased mineralization of the native soil organic fraction was also detected in samples that were not enriched with glucose when the bacterial suspension was first disintegrated ultrasonically and the material then used for inoculation. The possible participation of phenomena of the type of cometabolism and activation of cell membrane transport mechanisms on the occurrence of the priming effect of glucose in the soil is discussed. (author)

  19. Estimation of gluconeogenesis and glucose utilization in carbohydate deficient growing rats

    International Nuclear Information System (INIS)

    Hill, F.W.; Egtesadi, S.; Rucker, R.B.

    1986-01-01

    A carbohydrate deficient diet based on food grade oleic acid and soybean oil and a minimally adequate level of casein protein was supplemented with graded levels of glucose (0, 4, 10, 65%), and casein protein (12% basal level plus 4, 6, 20%). Weanling rats were fed the respective diets for 28 days. Under anesthesia in fed state, the right jugular vein and left carotid artery were cannulated. NaH 14 CO 3 and 3 H-glucose labelled on C 6 were injected into aorta via carotid and blood samples taken from vena cava via jugular over a period of 30 minutes. Rate of increase of blood 14 C-glucose was the indicator of gluconeogenesis (GLNG). Disappearance of blood 3 H-glucose was the measure of glucose flux. Relative rate of GLNG was very high in basal unsupplemented rats, and glucose flux was very low. Rats growing rapidly with minimum supplementation (4% glucose or 6% casein) showed the lowest relative rate of GLNG and maximum glucose flux, of the order of 10 mg min -1 kg -1 . GLNG increased with higher levels of glucose and casein, but flux did not increase. The fed state glucose flux extrapolated to 24 hour basis was approximately 2X greater than the dietary intake of glucose and its equivalent of glucogenic precursors in rats fed the basal diet and low levels of supplements. Adjustment for lower flux in post absorptive state, based on flux in fasted rats, reduced the differences between observed flux and intake

  20. Integration of a highly ordered gold nanowires array with glucose oxidase for ultra-sensitive glucose detection.

    Science.gov (United States)

    Cui, Jiewu; Adeloju, Samuel B; Wu, Yucheng

    2014-01-27

    A highly sensitive amperometric nanobiosensor has been developed by integration of glucose oxidase (GO(x)) with a gold nanowires array (AuNWA) by cross-linking with a mixture of glutaraldehyde (GLA) and bovine serum albumin (BSA). An initial investigation of the morphology of the synthesized AuNWA by field emission scanning electron microscopy (FESEM) and field emission transmission electron microscopy (FETEM) revealed that the nanowires array was highly ordered with rough surface, and the electrochemical features of the AuNWA with/without modification were also investigated. The integrated AuNWA-BSA-GLA-GO(x) nanobiosensor with Nafion membrane gave a very high sensitivity of 298.2 μA cm(-2) mM(-1) for amperometric detection of glucose, while also achieving a low detection limit of 0.1 μM, and a wide linear range of 5-6000 μM. Furthermore, the nanobiosensor exhibited excellent anti-interference ability towards uric acid (UA) and ascorbic acid (AA) with the aid of Nafion membrane, and the results obtained for the analysis of human blood serum indicated that the device is capable of glucose detection in real samples. Copyright © 2013 Elsevier B.V. All rights reserved.