WorldWideScience

Sample records for sample tube holder

  1. The effectiveness of an endotracheal tube holder

    Directory of Open Access Journals (Sweden)

    Byung Gun Lim

    2016-01-01

    Full Text Available The security of the endotracheal tube (ETT is important in the anesthesia and intensive care settings. Recently, an ETT holder instead of an adhesive tape is frequently used to provide the fixation of the ETT. There are some studies that focused on the effectiveness of the ETT holder in preventing displacement of ETT compared to an adhesive tape (1, 2. I have experienced the use of an ETT holder (E-holder, KS medical, Bucheon, Korea in many different anesthesia settings and recognized its usefulness and convenience other than ETT security in the following specific settings.  Firstly, the ETT holder is definitely effective for patients undergoing procedures that frequently require the adjustment of ETT (or double lumen tube location including thoracic surgery. The location of double lumen tube needed for lung separation can be modified for effective ventilation during anesthetic induction or surgery, and after position changes. The tube can be easily relocated to the proper place for lung separation and effective ventilation by unlocking/relocking the button of the ETT holder under flexible bronchoscopic guidance (Fig. 1A, which can facilitate the operative procedure to be performed easily and quickly. Secondly, the ETT holder can be useful in procedures requiring the prone position (3. Especially, it is useful in all circumstances requiring the adjustment of ETT in the prone position. For instance, it is definitely useful for patients with Duchene muscular dystrophy undergoing scoliosis surgery under prone position. Adolescent patients with Duchene muscular dystrophy frequently have tracheobronchial malacia. If so, the airway pressure can be elevated due to the narrowing of the lesion of malacia when changed to the prone position (4. To overcome this problem, a reinforced ETT should be relocated so that it passes the narrowed tracheal lesion under flexible bronchoscopic guidance (Fig. 1B. However, the approach for this management is somewhat

  2. Structural analysis of 177-FA redesigned surveillance specimen holder tube

    International Nuclear Information System (INIS)

    Pryor, C.W.; Thoren, D.E.; Vames, G.J.; Harris, R.J.

    1976-08-01

    Because of in-service operational problems, the surveillance specimen holder tubes described in B and W topical report BAW-10051 have been redesigned. This report describes the new design and structural analysis for normal operation and upset loading conditions. The results of the analysis demonstrate the adequacy of the new surveillance specimen holder tubes for their design life of 40 years

  3. Use of a holder-vacuum tube device to save on-site hands in preparing urine samples for head-space gas-chromatography, and its application to determine the time allowance for sample sealing.

    Science.gov (United States)

    Kawai, Toshio; Sumino, Kimiaki; Ohashi, Fumiko; Ikeda, Masayuki

    2011-01-01

    To facilitate urine sample preparation prior to head-space gas-chromatographic (HS-GC) analysis. Urine samples containing one of the five solvents (acetone, methanol, methyl ethyl ketone, methyl isobutyl ketone and toluene) at the levels of biological exposure limits were aspirated into a vacuum tube via holder, a device commercially available for venous blood collection (the vacuum tube method). The urine sample, 5 ml, was quantitatively transferred to a 20-ml head-space vial prior to HS-GC analysis. The loaded tubes were stored at +4 ℃ in dark for up to 3 d. The vacuum tube method facilitated on-site procedures of urine sample preparation for HS-GC with no significant loss of solvents in the sample and no need of skilled hands, whereas on-site sample preparation time was significantly reduced. Furthermore, no loss of solvents was detected during the 3-d storage, irrespective of hydrophilic (acetone) or lipophilic solvent (toluene). In a pilot application, high performance of the vacuum tube method in sealing a sample in an air-tight space succeeded to confirm that no solvent will be lost when sealing is completed within 5 min after urine voiding, and that the allowance time is as long as 30 min in case of toluene in urine. The use of the holder-vacuum tube device not only saves hands for transfer of the sample to air-tight space, but facilitates sample storage prior to HS-GC analysis.

  4. Transmission electron microscope sample holder with optical features

    Science.gov (United States)

    Milas, Mirko [Port Jefferson, NY; Zhu, Yimei [Stony Brook, NY; Rameau, Jonathan David [Coram, NY

    2012-03-27

    A sample holder for holding a sample to be observed for research purposes, particularly in a transmission electron microscope (TEM), generally includes an external alignment part for directing a light beam in a predetermined beam direction, a sample holder body in optical communication with the external alignment part and a sample support member disposed at a distal end of the sample holder body opposite the external alignment part for holding a sample to be analyzed. The sample holder body defines an internal conduit for the light beam and the sample support member includes a light beam positioner for directing the light beam between the sample holder body and the sample held by the sample support member.

  5. Sample holder for studying temperature dependent particle guiding

    International Nuclear Information System (INIS)

    Bereczky, R.J.; Toekesi, K.; Kowarik, G.; Aumayr, F.

    2011-01-01

    Complete text of publication follows. The so called guiding effect is a complex process involving the interplay of a large number of charged particles with a solid. Although many research groups joined this field and carried out various experiments with insulator capillaries many details of the interactions are still unknown. We investigated the temperature dependence of the guiding since it opens new possibilities both for a fundamental understanding of the guiding phenomenon and for applications. For the temperature dependent guiding experiments a completely new heatable sample holder was designed. We developed and built such a heatable sample holder to make accurate and reproducible studies of the temperature dependence of the ion guiding effect possible. The target holder (for an exploded view see Fig. 1) consists of two main parts, the front and the back plates. The two plates of the sample holder, which function as an oven, are made of copper. These parts surround the capillary in order to guarantee a uniform temperature along the whole tube. The temperature of the copper parts is monitored by a K-Type thermocouple. Stainless steel coaxial heaters surrounding the oven are used for heating. The heating power up to a few watts is regulated by a PID controller. Cooling of the capillary is achieved by a copper feed-through connected to a liquid nitrogen bath outside the UHV chamber. This solution allows us to change the temperature of the sample from -30 deg C up to 90 deg C. Our experiments with this newly developed temperature regulated capillary holder show that the glass temperature (i.e. conductivity) can be used to control the guiding properties of the glass capillary and adjust the conditions from guiding at room temperature to simple geometrical transmission at elevated temperatures. This holds the promise to investigate the effect of conductivity on particle transport (build-up and removal of charge patches) through capillaries in more details

  6. Manipulator for rotating and translating a sample holder

    Science.gov (United States)

    van de Water, Jeroen [Breugel, NL; van den Oetelaar, Johannes [Eindhoven, NL; Wagner, Raymond [Gorinchem, NL; Slingerland, Hendrik Nicolaas [Venlo, NL; Bruggers, Jan Willem [Eindhoven, NL; Ottevanger, Adriaan Huibert Dirk [Malden, NL; Schmid, Andreas [Berkeley, CA; Olson, Eric A [Champaign, IL; Petrov, Ivan G [Champaign, IL; Donchev, Todor I [Urbana, IL; Duden, Thomas [Kensington, CA

    2011-02-08

    A manipulator for use in e.g. a Transmission Electron Microscope (TEM) is described, said manipulator capable of rotating and translating a sample holder (4). The manipulator clasps the round sample holder between two members (3A, 3B), said members mounted on actuators (2A, 2B). Moving the actuators in the same direction results in a translation of the sample holder, while moving the actuators in opposite directions results in a rotation of the sample holder.

  7. Tem holder for sample transfer under reaction conditions

    DEFF Research Database (Denmark)

    Damsgaard, Christian Danvad; Zandbergen, Henny W.; Wagner, Jakob Birkedal

    Environmental transmission electron microscopy (ETEM) studies are usually performed using conventional sample holders in a dedicated ETEM [1] or in a traditional TEM by use of a dedicated high-pressure cell sample holder [2]. In both cases, the setup defines the conditions regarding gas, pressure......]. Furthermore, dedicated transfer holders have been used to transfer catalyst samples between reactor set-ups and TEM at room temperature in inert atmosphere [5]. To take the full advantage of complementary in situ techniques, transfer under reactions conditions is essential. This study introduces the in situ...... transfer concept by use of a dedicated TEM transfer holder capable of enclosing the sample in a gaseous environment at temperatures up to approx. 900C. By oxidation and reduction experiments of Cu nanoparticles it is shown possible to keep the reaction conditions during transfer outside the microscope...

  8. 3D printing scanning electron microscopy sample holders: A quick and cost effective alternative for custom holder fabrication.

    Directory of Open Access Journals (Sweden)

    Gabriel N Meloni

    Full Text Available A simple and cost effective alternative for fabricating custom Scanning Electron Microscope (SEM sample holders using 3D printers and conductive polylactic acid filament is presented. The flexibility of the 3D printing process allowed for the fabrication of sample holders with specific features that enable the high-resolution imaging of nanoelectrodes and nanopipettes. The precise value of the inner semi cone angle of the nanopipettes taper was extracted from the acquired images and used for calculating their radius using electrochemical methods. Because of the low electrical resistivity presented by the 3D printed holder, the imaging of non-conductive nanomaterials, such as alumina powder, was found to be possible. The fabrication time for each sample holder was under 30 minutes and the average cost was less than $0.50 per piece. Despite being quick and economical to fabricate, the sample holders were found to be sufficiently resistant, allowing for multiple uses of the same holder.

  9. Improved sample holders for the PMMA dosimeters

    International Nuclear Information System (INIS)

    Kobayashi, Toshikazu; Sone, Koji; Iso, Katsuaki

    1994-01-01

    PMMA dosimeters are widely used for high dose dosimetry. Dose is determined by measuring the change in optical density of the irradiated PMMA dosimeter element. Measurement precision depends on the mounting method of a dosimeter element in the sample room of a spectrophotometer. We tried to prepare three types of holders, (holders A, B and C in Figs. 1-3), according to the shape of PMMA dosimeter elements. We measured optical density of the irradiated PMMA dosimeter elements by using the three types of holders. It is revealed that the holder of the type A gives more precise results for the Red 4034 or Gammachrome YR dosimeter than that of the type B. The measurements with a spectrophotometer using the type C holder gives better results for the Red acrylic dosimeter than the case of the measurements by the exclusive reader. (author)

  10. Broadband sample holder for microwave spectroscopy of superconducting qubits

    International Nuclear Information System (INIS)

    Averkin, A. S.; Karpov, A.; Glushkov, E.; Abramov, N.; Shulga, K.; Huebner, U.; Il'ichev, E.; Ustinov, A. V.

    2014-01-01

    We present a practical design and implementation of a broadband sample holder suitable for microwave experiments with superconducting integrated circuits at millikelvin temperatures. Proposed design can be easily integrated in standard dilution cryostats, has flat pass band response in a frequency range from 0 to 32 GHz, allowing the RF testing of the samples with substrate size up to 4 × 4 mm 2 . The parasitic higher modes interference in the holder structure is analyzed and prevented via design considerations. The developed setup can be used for characterization of superconducting parametric amplifiers, bolometers, and qubits. We tested the designed sample holder by characterizing of a superconducting flux qubit at 20 mK temperature

  11. Liquid scintillation systems and apparatus for measuring high-energy radiation emitted by samples in standard laboratory test tubes

    International Nuclear Information System (INIS)

    Benvenutti, R.A.

    1976-01-01

    Liquid scintillation detection system employs improved sample holders in which the cap of a glass vial is provided with a well for receiving a standard laboratory test tube containing a radioactive sample. The well is immersed in a liquid scintillator in the vial, the scintillator containing lead acetate solution to enhance its efficiency. A commercially available beta-counting liquid scintillation apparatus is modified to provide gamma-counting with the improved sample holders

  12. Automatic gamma radiation scanning device and feed mechanism for plural sample holders

    International Nuclear Information System (INIS)

    Byrd, W.J.

    1976-01-01

    Apparatus is disclosed for measuring the level of gamma radiation contained in a plurality of biological samples which are located on the fibrous sheet member carried by a sample holder. The apparatus is adapted to count the radiation level of the number of closely spaced samples located in rows and columns on the sheet by automatically sequencing through the individual samples within the rows and to advance the holder to bring successive rows into proximity with the detector. The detector is moved from sample to sample within the rows, although a number of detectors can be employed. A plurality of sample holders are automatically advanced to the detector. 25 claims, 5 drawing figures

  13. Towards a compact and precise sample holder for macromolecular crystallography.

    Science.gov (United States)

    Papp, Gergely; Rossi, Christopher; Janocha, Robert; Sorez, Clement; Lopez-Marrero, Marcos; Astruc, Anthony; McCarthy, Andrew; Belrhali, Hassan; Bowler, Matthew W; Cipriani, Florent

    2017-10-01

    Most of the sample holders currently used in macromolecular crystallography offer limited storage density and poor initial crystal-positioning precision upon mounting on a goniometer. This has now become a limiting factor at high-throughput beamlines, where data collection can be performed in a matter of seconds. Furthermore, this lack of precision limits the potential benefits emerging from automated harvesting systems that could provide crystal-position information which would further enhance alignment at beamlines. This situation provided the motivation for the development of a compact and precise sample holder with corresponding pucks, handling tools and robotic transfer protocols. The development process included four main phases: design, prototype manufacture, testing with a robotic sample changer and validation under real conditions on a beamline. Two sample-holder designs are proposed: NewPin and miniSPINE. They share the same robot gripper and allow the storage of 36 sample holders in uni-puck footprint-style pucks, which represents 252 samples in a dry-shipping dewar commonly used in the field. The pucks are identified with human- and machine-readable codes, as well as with radio-frequency identification (RFID) tags. NewPin offers a crystal-repositioning precision of up to 10 µm but requires a specific goniometer socket. The storage density could reach 64 samples using a special puck designed for fully robotic handling. miniSPINE is less precise but uses a goniometer mount compatible with the current SPINE standard. miniSPINE is proposed for the first implementation of the new standard, since it is easier to integrate at beamlines. An upgraded version of the SPINE sample holder with a corresponding puck named SPINEplus is also proposed in order to offer a homogenous and interoperable system. The project involved several European synchrotrons and industrial companies in the fields of consumables and sample-changer robotics. Manual handling of mini

  14. A sample holder for the study of isothermal heat of hydration of cement

    DEFF Research Database (Denmark)

    Hansen, Per Freiesleben; Jensen, Ole Mejlhede

    1998-01-01

    Different techniques for measuring heat of hydration of cement are discussed, and a sample holder designed specially for measuring isothermal heat of hydration is described. A particular characteristic of the sample holder is the vacuum mixing technique which ensures a momentary and homogeneous...

  15. A sample holder for in-house X-ray powder diffraction studies of protein powders

    DEFF Research Database (Denmark)

    Frankær, Christian Grundahl; Harris, Pernille; Ståhl, Kenny

    2011-01-01

    A sample holder for handling samples of protein for in-house X-ray powder diffraction (XRPD) analysis has been made and tested on lysozyme. The use of an integrated pinhole reduced the background, and good signal-to-noise ratios were obtained from only 7 l of sample, corresponding to approximatel...... 2-3 mg of dry protein. The sample holder is further adaptable to X-ray absorption spectroscopy (XAS) measurements. Both XRPD and XAS at the Zn K-edge were tested with hexameric Zn insulin....

  16. A comparison of tape-tying versus a tube-holding device for securing endotracheal tubes in adults.

    Science.gov (United States)

    Murdoch, E; Holdgate, A

    2007-10-01

    During the transfer of intubated patients, endotracheal tube security is paramount. This study aims to compare two methods of securing an endotracheal tube in adults: tying with a cloth tape versus the Thomas Endotracheal Tube Holder (Laerdal). A manikin-based study was performed using paramedics and critical care doctors (consultants and senior trainees) as participants. Each participant was asked to secure an endotracheal tube that had been placed within the trachea of a manikin a total of six times, the first three times using tied cloth tape and the last three times using a Thomas Endotracheal Tube Holder. Following each 'fixation' and after the participant had left the room, the security of the tube was tested by applying a fixed force laterally and to the right by dropping a 1.25 kg weight a distance of 50 cm. The amount of movement of the tube with respect to the teeth was measured and recorded in millimetres. Two-hundred-and-seventy tube fixations (135 tied vs. 135 tube holder) were performed by 45 participants. The degree of tube movement was significantly higher when the tube was secured with a tie compared with when the tube holder was used (median movement 22 mm vs. 4 mm, P tube holder device minimised tube movement in a manikin model when compared with conventional tape tying. The use of this device when transporting intubated patients may reduce the risk of tube displacement though further clinical studies are warranted.

  17. Evaluation of the uncertainty associated with sample holders in NAA measurements in LAN/IPEN

    Energy Technology Data Exchange (ETDEWEB)

    Zahn, Guilherme S.; Ticianelli, Regina B.; Saiki, Mitiko; Genezini, Frederico A., E-mail: ticianelli@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    In IPEN's Neutron Activation Laboratory (LAN/IPEN), thin stainless steel sample holders are used for gamma spectrometry in NAA measurements. This material is very practical, but its chemical composition may be troublesome, as it presents large amounts of elements with intermediate atomic number, with attenuation factors for low-energy gamma-rays that must not be neglected. In this study, count rates obtained using different sample holders were compared. To accomplish that, an Am-241 source, with 59-keV gamma emission, was used so that low-energy gamma attenuation differences can be determined. Moreover, in order to study the energy dependence of these differences, a Ho-166m source was also used. From these results, it was possible to analyze the experimental error associated to the variations between sample holders, with the aim of introducing an addictive term to the uncertainty analysis of comparative Neutron Activation Analysis results. (author)

  18. Breeding snow: an instrumented sample holder for simultaneous tomographic and thermal studies

    International Nuclear Information System (INIS)

    Pinzer, B; Schneebeli, M

    2009-01-01

    To study the recrystallization processes during temperature gradient metamorphism of snow, we developed a sample holder that allows applying well-defined and stable thermal gradients to a snow sample while it is scanned in an x-ray micro-tomograph. To this end, both the thermal insulation of the sample as well as image contrast and resolution of the tomography had to be optimized. We solved this conflict by using thin aluminum cylinders in combination with highly insulating foam. This design is light, does not corrupt image quality and provides very good thermal decoupling from the environment. The sample holder was instrumented to measure the effective conductivity of the snow sample and calibrated using five materials of known conductivity. Finite element simulations were consistent with the calibration measurements and gave insight into the internal temperature and heat flux fields. With this setup, geometric and thermal evolution of snow under realistic thermal boundary conditions like alternating temperature gradients can be measured

  19. Note: A scanning electron microscope sample holder for bidirectional characterization of atomic force microscope probe tips

    Energy Technology Data Exchange (ETDEWEB)

    Eisenstein, Alon; Goh, M. Cynthia [Department of Chemistry and Institute for Optical Sciences, University of Toronto, 80 St. George Street, Toronto M5S 3H6 (Canada)

    2012-03-15

    A novel sample holder that enables atomic force microscopy (AFM) tips to be mounted inside a scanning electron microscopy (SEM) for the purpose of characterizing the AFM tips is described. The holder provides quick and easy handling of tips by using a spring clip to hold them in place. The holder can accommodate two tips simultaneously in two perpendicular orientations, allowing both top and side view imaging of the tips by the SEM.

  20. Sample summary report for ARG 1 pressure tube sample

    International Nuclear Information System (INIS)

    Belinco, C.

    2006-01-01

    The ARG 1 sample is made from an un-irradiated Zr-2.5% Nb pressure tube. The sample has 103.4 mm ID, 112 mm OD and approximately 500 mm length. A punch mark was made very close to one end of the sample. The punch mark indicates the 12 O'clock position and also identifies the face of the tube for making all the measurements. ARG 1 sample contains flaws on ID and OD surface. There was no intentional flaw within the wall of the pressure tube sample. Once the flaws are machined the pressure tube sample was covered from outside to hide the OD flaws. Approximately 50 mm length of pressure tube was left open at both the ends to facilitate the holding of sample in the fixtures for inspection. No flaw was machined in this zone of 50 mm on either end of the pressure tube sample. A total of 20 flaws were machined in ARG 1 sample. Out of these, 16 flaws were on the OD surface and the remaining 4 on the ID surface of the pressure tube. The flaws were characterized in to various groups like axial flaws, circumferential flaws, etc

  1. A new sample holder for laser-excited pump-probe magnetic measurements on a Focus photoelectron emission microscope

    International Nuclear Information System (INIS)

    Miguel, Jorge; Bernien, Matthias; Kuch, Wolfgang; Bayer, Daniela; Aeschlimann, Martin; Sanchez-Barriga, Jaime; Kronast, Florian; Duerr, Hermann A.

    2008-01-01

    A custom-made Omicron-compatible sample holder for time-resolved photoelectron emission microscopy experiments is presented. It comprises a sample plate with four contacts that hosts a chip carrier where the semiconductor substrate is mounted. Covering the sample holder, a 6 mm diameter mask protects electrostatically the sample from the extractor lens voltage while keeping the imaging quality unperturbed. The improvements are a greater sample lifetime and the ability to withstand much higher currents in the stripline that provides the magnetic pulse to the magnetic microstructure

  2. A 'smart' tube holder enables real-time sample monitoring in a standard lab centrifuge.

    Science.gov (United States)

    Hoang, Tony; Moskwa, Nicholas; Halvorsen, Ken

    2018-01-01

    The centrifuge is among the oldest and most widely used pieces of laboratory equipment, with significant applications that include clinical diagnostics and biomedical research. A major limitation of laboratory centrifuges is their "black box" nature, limiting sample observation to before and after centrifugation. Thus, optimized protocols require significant trial and error, while unoptimized protocols waste time by centrifuging longer than necessary or material due to incomplete sedimentation. Here, we developed an instrumented centrifuge tube receptacle compatible with several commercial benchtop centrifuges that can provide real-time sample analysis during centrifugation. We demonstrated the system by monitoring cell separations during centrifugation for different spin speeds, concentrations, buffers, cell types, and temperatures. We show that the collected data are valuable for analytical purposes (e.g. quality control), or as feedback to the user or the instrument. For the latter, we verified an adaptation where complete sedimentation turned off the centrifuge and notified the user by a text message. Our system adds new functionality to existing laboratory centrifuges, saving users time and providing useful feedback. This add-on potentially enables new analytical applications for an instrument that has remained largely unchanged for decades.

  3. Pneumatic tube-transported blood samples in lithium heparinate gel separator tubes may be more susceptible to haemolysis than blood samples in serum tubes.

    Science.gov (United States)

    Böckel-Frohnhöfer, Nicole; Hübner, Ulrich; Hummel, Björn; Geisel, Jürgen

    2014-10-01

    Pneumatic tube systems are widely used in hospitals. Advantages are high speed and rapid availability of the samples. However, the transportation by pneumatic tube promotes haemolysis. Haemolysis interferes with many spectrophotometric assays and is a common problem in clinical laboratories. The haemolysis index (HI) as a semi-quantitative representation of the level of haemolysis was compared in unpaired tube-transported and hand-delivered routine lithium heparinate plasma samples (n = 1368 and n = 837, respectively). Additionally, the HI distribution was measured in lithium heparinate plasma samples with a HI above the threshold value of 20 and in paired serum samples after transportation by pneumatic tube system. HI values above 20 can interfere with the selected assays: Creatine kinase (CK), creatine kinase-MB (CK-MB) and alanine aminotransferase (ALT) activities. These parameters were determined to demonstrate how haemolysis affects the results. 17.5% of the tube-transported plasma samples and 2.6% of the hand-delivered plasma samples had a HI above 20. The median HI in pneumatic tube-transported lithium heparinate plasma was 85 and 33 in the paired serum samples. The median HI difference between paired plasma and serum was 46. Blood samples in lithium heparinate tubes may be substantially more susceptible to haemolysis by pneumatic tube transportation than serum tube samples. Although our results cannot be universally applied to laboratories with different pneumatic tube systems, it is recommended that each laboratory evaluate carefully the degree of haemolysis after the transportation by the own pneumatic tube system and in terms of the sample type.

  4. PWR steam generator tubing sample library

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    In order to compile the tubing sample library, two approaches were employed: (a) tubing sample replication by either chemical or mechanical means, based on field tube data and metallography reports for tubes already destructively examined; and (b) acquisition of field tubes removed from operating or retired steam generators. In addition, a unique mercury modeling concept is in use to guide the selection of replica samples. A compendium was compiled that summarizes field observations and morphologies of steam generator tube degradation types based on available NDE, destructive examinations, and field reports. This compendium was used in selecting candidate degradation types that were manufactured for inclusion in the tube library

  5. Dose computation of Ti activated products for its qualification as a material for the sample holder in FBTR

    International Nuclear Information System (INIS)

    Ashok Kumar, G.V.S.; Kumar, R.; Venkatasubramani, C.R.; Acharya, R.; Reddy, A.V.R.

    2014-01-01

    Development of a Fast flux experimental facility with a sample holder facility in FBTR has been envisaged to carry out the studies on i) fast neutron activation analysis and ii) fission studies. This paper describes the facility in detail and dose computations that are to be generated due to long irradiation of the material of the sample holder i.e. titanium. (author)

  6. Practical aspects of the use of the X(2) holder for HRTEM-quality TEM sample preparation by FIB.

    Science.gov (United States)

    van Mierlo, Willem; Geiger, Dorin; Robins, Alan; Stumpf, Matthias; Ray, Mary Louise; Fischione, Paul; Kaiser, Ute

    2014-12-01

    The X(2) holder enables the effective production of thin, electron transparent samples for high-resolution transmission electron microscopy (HRTEM). Improvements to the X(2) holder for high-quality transmission electron microscopy (TEM) sample preparation are presented in this paper. We discuss the influence of backscattered electrons (BSE) from the sample holder in determining the lamella thickness in situ and demonstrate that a significant improvement in thickness determination can be achieved by comparatively simple means using the relative BSE intensity. We show (using Monte Carlo simulations) that by taking into account the finite collection angle of the electron backscatter detector, an approximately 20% underestimation of the lamella thickness in a silicon sample can be avoided. However, a correct thickness determination for light-element lamellas still remains a problem with the backscatter method; we introduce a more accurate method using the energy dispersive X-ray spectroscopy (EDX) signal for in situ thickness determination. Finally, we demonstrate how to produce a thin lamella with a nearly damage-free surface using the X(2) holder in combination with sub-kV polishing in the Fischione Instruments׳ NanoMill(®) TEM specimen preparation system. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. A ‘smart’ tube holder enables real-time sample monitoring in a standard lab centrifuge

    Science.gov (United States)

    Hoang, Tony; Moskwa, Nicholas

    2018-01-01

    The centrifuge is among the oldest and most widely used pieces of laboratory equipment, with significant applications that include clinical diagnostics and biomedical research. A major limitation of laboratory centrifuges is their “black box” nature, limiting sample observation to before and after centrifugation. Thus, optimized protocols require significant trial and error, while unoptimized protocols waste time by centrifuging longer than necessary or material due to incomplete sedimentation. Here, we developed an instrumented centrifuge tube receptacle compatible with several commercial benchtop centrifuges that can provide real-time sample analysis during centrifugation. We demonstrated the system by monitoring cell separations during centrifugation for different spin speeds, concentrations, buffers, cell types, and temperatures. We show that the collected data are valuable for analytical purposes (e.g. quality control), or as feedback to the user or the instrument. For the latter, we verified an adaptation where complete sedimentation turned off the centrifuge and notified the user by a text message. Our system adds new functionality to existing laboratory centrifuges, saving users time and providing useful feedback. This add-on potentially enables new analytical applications for an instrument that has remained largely unchanged for decades. PMID:29659624

  8. A cylindrical specimen holder for electron cryo-tomography

    International Nuclear Information System (INIS)

    Palmer, Colin M.; Löwe, Jan

    2014-01-01

    The use of slab-like flat specimens for electron cryo-tomography restricts the range of viewing angles that can be used. This leads to the “missing wedge” problem, which causes artefacts and anisotropic resolution in reconstructed tomograms. Cylindrical specimens provide a way to eliminate the problem, since they allow imaging from a full range of viewing angles around the tilt axis. Such specimens have been used before for tomography of radiation-insensitive samples at room temperature, but never for frozen-hydrated specimens. Here, we demonstrate the use of thin-walled carbon tubes as specimen holders, allowing the preparation of cylindrical frozen-hydrated samples of ribosomes, liposomes and whole bacterial cells. Images acquired from these cylinders have equal quality at all viewing angles, and the accessible tilt range is restricted only by the physical limits of the microscope. Tomographic reconstructions of these specimens demonstrate that the effects of the missing wedge are substantially reduced, and could be completely eliminated if a full tilt range was used. The overall quality of these tomograms is still lower than that obtained by existing methods, but improvements are likely in future. - Highlights: • The missing wedge is a serious problem for electron cryo-tomography. • Cylindrical specimens allow the missing wedge to be eliminated. • Carbon nanopipettes can be used as cylindrical holders for tomography of frozen-hydrated specimens. • Cryo-tomography of cylindrical biological samples demonstrates a reduction of deleterious effects associated with the missing wedge

  9. Advanced pressure tube sampling tools

    International Nuclear Information System (INIS)

    Wittich, K.C.; King, J.M.

    2002-01-01

    Deuterium concentration is an important parameter that must be assessed to evaluate the Fitness for service of CANDU pressure tubes. In-reactor pressure tube sampling allows accurate deuterium concentration assessment to be made without the expenses associated with fuel channel removal. This technology, which AECL has developed over the past fifteen years, has become the standard method for deuterium concentration assessment. AECL is developing a multi-head tool that would reduce in-reactor handling overhead by allowing one tool to sequentially sample at all four axial pressure tube locations before removal from the reactor. Four sets of independent cutting heads, like those on the existing sampling tools, facilitate this incorporating proven technology demonstrated in over 1400 in-reactor samples taken to date. The multi-head tool is delivered by AECL's Advanced Delivery Machine or other similar delivery machines. Further, AECL has developed an automated sample handling system that receives and processes the tool once out of the reactor. This system retrieves samples from the tool, dries, weighs and places them in labelled vials which are then directed into shielded shipping flasks. The multi-head wet sampling tool and the automated sample handling system are based on proven technology and offer continued savings and dose reduction to utilities in a competitive electricity market. (author)

  10. Film holder for radiographing tubing

    International Nuclear Information System (INIS)

    Davis, E.V.; Foster, B.E.

    1976-01-01

    A film cassette is described which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro

  11. Film holder for radiographing tubing

    Science.gov (United States)

    Davis, Earl V.; Foster, Billy E.

    1976-01-01

    A film cassette is provided which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro.

  12. In situ sampling for pressure tube deuterium concentration

    International Nuclear Information System (INIS)

    Harrington, A.J.; Kittmer, C.A.

    1988-01-01

    The present method of assessing the useful life of pressure tubes in CANDU (CANada Deuterium Uranium) reactors requires the periodic removal and examination of a tube. Special tooling was developed at Atomic Energy of Canada Limited (AECL) to obtain a sample of material from a pressure tube without removing the tube from the reactor. The sampling tool concept has been successfully used by Ontario Hydro during scheduled outages at the Pickering Nuclear Generating Station (PNGS). (author)

  13. Failure analysis of burst tested fuel tube samples

    International Nuclear Information System (INIS)

    Padmaprabu, C.; Ramana Rao, S.V.; Srivatsava, R.K.

    2005-01-01

    The Total Circumferential Elongation (TCE) is an important parameter for evaluation of ductility of the Zircaloy-4 fuel tubes for the PHWR reactors. The TCE values of the fuel tubes were obtained using the burst testing technique. In some lots there is a variation in the values of the TCE. To investigate the reasons for such a large variation in the TCE, samples were selected at appropriate intervals and sectioned at the fractured portion. The surface morphology of the fractured surfaces was examined under Scanning Electron Microscope (SEM) equipped with Energy Dispersive Spectrometer (EDS). The morphologies show segregation of elements at specific locations. Energy dispersive spectra was obtained from those segregated particles. According to the magnitude of TCE value the samples were classified into low, intermediate and high ductility. Low ductility samples were found to contain large amount of segregations along the thickness direction of the tube. This forms a brittle region and a path for the easy crack growth along thickness direction. In the case of intermediate samples the segregation occurred in fewer locations compared to low ductile samples and also confined to the circumferential direction of the outside surface of the tube. Due to this, probability of crack formation at the surface of the tube could be high. But crack growth would be slower in the ductile matrix along the thickness direction resulting in the enhancement of TCE value compared to the low ductile sample. In the high ductile samples, the segregations were very scarce and found to be isolated and embedded in the ductile matrix. The mode of failure in these types of samples was found to be purely ductile. Cracks were found to originate solely from the micro voids in the material. As the probability of crack formation and its propagation is low, very high TCE values were observed in these samples. Microstructural observations of fractured surfaces and EDAX analysis was able to identify the

  14. Data analysis for steam generator tubing samples

    International Nuclear Information System (INIS)

    Dodd, C.V.

    1996-07-01

    The objective of the Improved Eddy-Current ISI for Steam Generators program is to upgrade and validate eddy-current inspections, including probes, instrumentation, and data processing techniques for inservice inspection of new, used, and repaired steam generator tubes; to improve defect detection, classification and characterization as affected by diameter and thickness variations, denting, probe wobble, tube sheet, tube supports, copper and sludge deposits, even when defect types and other variables occur in combination; to transfer this advanced technology to NRC's mobile NDE laboratory and staff. This report provides a description of the application of advanced eddy-current neural network analysis methods for the detection and evaluation of common steam generator tubing flaws including axial and circumferential outer-diameter stress-corrosion cracking and intergranular attack. The report describes the training of the neural networks on tubing samples with known defects and the subsequent evaluation results for unknown samples. Evaluations were done in the presence of artifacts. Computer programs are given in the appendix

  15. Sampling of high molecular weight hydrocarbons with adsorbent tubes

    International Nuclear Information System (INIS)

    Stroemberg, B.

    1996-12-01

    Adsorption tubes have been used to determine the content of hydrocarbons in gas samples from small scale combustion and gasification of biomass. Compounds from benzene (mw 78) to indeno (1,2,3-cd) pyrene (mw 276) have been examined. The results show that it is possible to analyze polyaromatic hydrocarbons (PAH) with 4 aromatic rings (mw 202). Detection limits for these compounds are 3 . PAH with higher molecule weight can be identified and quantified in samples with high amounts of PAH e.g. at gasification of biomass. Sampling on adsorption tubes is extremely quick and easy. The tube is inserted in the gas of interest and the sample is sucked through the tube with a pump. Sampling times of 2-10 minutes are often sufficient. High moisture content in the gas may result in losses of the most volatile compounds, when drying. Even very low concentrations of water in the tube may cause ice formation in the cold-trap and the sample will be destroyed. The analysis is unfortunately time-consuming because the desorption oven must be cooled between every analysis. This will reduce the number of samples which can be analyzed per day. The tubes can be stored for several weeks before analysis without deterioration. 4 refs, 5 figs, 3 tabs

  16. Remotised sliver sample removal from irradiated pressure tube

    Energy Technology Data Exchange (ETDEWEB)

    Rupani, B B; Sharma, B S.V.G.; Shyam, T V; Sinha, R K [Bhabha Atomic Research Centre, Bombay (India). Reactor Engineering Div.

    1994-12-31

    The life of irradiated pressure tubes of Pressurised Heavy Water Reactor (PHWR) can be assessed by analysing hydrogen content in sliver samples of pressure tube material. The sample can be obtained in the form of small slivers by scraping at any specified locations within the bore of the pressure tube of operating reactor. A tool namely Hydride Scraping Tool (HST) has been developed to obtain very thin slivers of hydride bearing samples from irradiated pressure tube. In order to save man-rem consumption during scraping operation, a feeding mechanism has also been designed and developed for axial positioning of scraping tool in the channel remotely. This paper covers general details about constructional features of the scraping tool, feeding mechanism and their control system. It also highlights the operational salient features and capabilities of the system. Possible applications of the feeding mechanism in other fields are also indicated. (author). 4 figs.

  17. Remotised sliver sample removal from irradiated pressure tube

    International Nuclear Information System (INIS)

    Rupani, B.B.; Sharma, B.S.V.G.; Shyam, T.V.; Sinha, R.K.

    1994-01-01

    The life of irradiated pressure tubes of Pressurised Heavy Water Reactor (PHWR) can be assessed by analysing hydrogen content in sliver samples of pressure tube material. The sample can be obtained in the form of small slivers by scraping at any specified locations within the bore of the pressure tube of operating reactor. A tool namely Hydride Scraping Tool (HST) has been developed to obtain very thin slivers of hydride bearing samples from irradiated pressure tube. In order to save man-rem consumption during scraping operation, a feeding mechanism has also been designed and developed for axial positioning of scraping tool in the channel remotely. This paper covers general details about constructional features of the scraping tool, feeding mechanism and their control system. It also highlights the operational salient features and capabilities of the system. Possible applications of the feeding mechanism in other fields are also indicated. (author). 4 figs

  18. Radiation damage studies of straw tube and scintillating fiber elements

    International Nuclear Information System (INIS)

    Dunn, W.L.; Elleman, T.S.; Goshaw, A.T.; Oh, S.H.; Robertson, W.J.; Grimes, A.; Leedom, I.; Reucroft, S.

    1990-01-01

    The authors report on the results of mixed-field irradiations of straw-tube, plastic scintillating fiber, and avalanche photodiode components. These irradiations are being carried out at the one-MW PULSTAR research reactor facility at North Carolina State University. A special sample holder was designed that allows relatively uniform irradiation of samples up to 5 ft long, without bending or coiling. A systematic irradiation program is underway that allows study of total fluence, fluence-rate, and neutron spectral effects. Samples have been exposed to neutron fluences as high as 2 x 10 16 cm -2

  19. Bacteriological, biochemical, and immunological modifications in human colostrum after Holder pasteurisation.

    Science.gov (United States)

    Espinosa-Martos, I; Montilla, A; de Segura, A Gómez; Escuder, D; Bustos, G; Pallás, C; Rodríguez, J M; Corzo, N; Fernández, L

    2013-05-01

    The objective of this work was to evaluate the effect of Holder pasteurisation of human colostrum on a variety of microbiological, biochemical, and immunological parameters. Colostrum samples from 10 donors, and 8 samples of mature milk used as controls, were heated at 62.5°C for 30 minutes. Bacterial counts and the concentration of furosine, lactose, myoinositol, glucose, lactulose, cytokines, and immunoglobulins were determined before and after the heat treatment. Mean bacterial counts in nonpasteurised colostrum samples oscillated between 2.72 and 4.13 log10 colony-forming units per millilitre in the agar media tested. Holder pasteurisation led to the destruction of the bacteria originally present in the samples. Furosine was detected in all samples before pasteurisation and increased significantly after the heat treatment (from 6.60 to 20.59 mg/100 g protein). Lactulose content was below the detection limit in nonpasteurised colostrum, but it was detected in all samples and quantified in 7 of them (from 10.68 to 38.02 mg/L) after Holder pasteurisation. Lactose, glucose, and myoinositol concentrations did not change after Holder pasteurisation. The concentrations of most cytokines and immunoglobulins were significantly higher in colostrum than in mature milk samples. Immunoglobulin content, both in colostrum and in milk samples, was reduced during pasteurisation, whereas, among cytokines, only macrophage inflammatory protein-1β, interleukin-7, and granulocyte-macrophage-colony-stimulating factor concentrations were affected by this heat treatment. Lactulose and furosine content could be used as heat treatment indicators in colostrum samples. Holder pasteurisation modified the immunological profile of both colostrum and mature milk.

  20. Compact design of a transmission electron microscope-scanning tunneling microscope holder with three-dimensional coarse motion

    International Nuclear Information System (INIS)

    Svensson, K.; Jompol, Y.; Olin, H.; Olsson, E.

    2003-01-01

    A scanning tunneling microscope (STM) with a compact, three-dimensional, inertial slider design is presented. Inertial sliding of the STM tip, in three dimensions, enables coarse motion and scanning using only one piezoelectric tube. Using the same electronics both for scanning and inertial sliding, step lengths of less than 5% of the piezo range were achieved. The compact design, less than 1 cm3 in volume, ensures a low mechanical noise level and enables us to fit the STM into the sample holder of a transmission electron microscope (TEM), while maintaining atomic scale resolution in both STM and TEM imaging

  1. Preparation and Loading Process of Single Crystalline Samples into a Gas Environmental Cell Holder for In Situ Atomic Resolution Scanning Transmission Electron Microscopic Observation.

    Science.gov (United States)

    Straubinger, Rainer; Beyer, Andreas; Volz, Kerstin

    2016-06-01

    A reproducible way to transfer a single crystalline sample into a gas environmental cell holder for in situ transmission electron microscopic (TEM) analysis is shown in this study. As in situ holders have only single-tilt capability, it is necessary to prepare the sample precisely along a specific zone axis. This can be achieved by a very accurate focused ion beam lift-out preparation. We show a step-by-step procedure to prepare the sample and transfer it into the gas environmental cell. The sample material is a GaP/Ga(NAsP)/GaP multi-quantum well structure on Si. Scanning TEM observations prove that it is possible to achieve atomic resolution at very high temperatures in a nitrogen environment of 100,000 Pa.

  2. Evaluation of sampling schemes for in-service inspection of steam generator tubing

    International Nuclear Information System (INIS)

    Hanlen, R.C.

    1990-03-01

    This report is a follow-on of work initially sponsored by the US Nuclear Regulatory Commission (Bowen et al. 1989). The work presented here is funded by EPRI and is jointly sponsored by the Electric Power Research Institute (EPRI) and the US Nuclear Regulatory Commission (NRC). The goal of this research was to evaluate fourteen sampling schemes or plans. The main criterion used for evaluating plan performance was the effectiveness for sampling, detecting and plugging defective tubes. The performance criterion was evaluated across several choices of distributions of degraded/defective tubes, probability of detection (POD) curves and eddy-current sizing models. Conclusions from this study are dependent upon the tube defect distributions, sample size, and expansion rules considered. As degraded/defective tubes form ''clusters'' (i.e., maps 6A, 8A and 13A), the smaller sample sizes provide a capability of detecting and sizing defective tubes that approaches 100% inspection. When there is little or no clustering (i.e., maps 1A, 20 and 21), sample efficiency is approximately equal to the initial sample size taken. Thee is an indication (though not statistically significant) that the systematic sampling plans are better than the random sampling plans for equivalent initial sample size. There was no indication of an effect due to modifying the threshold value for the second stage expansion. The lack of an indication is likely due to the specific tube flaw sizes considered for the six tube maps. 1 ref., 11 figs., 19 tabs

  3. Acceptance Testing of Thermoluminescent Dosimeter Holders.

    Science.gov (United States)

    Romanyukha, Alexander; Grypp, Matthew D; Sharp, Thad J; DiRito, John N; Nelson, Martin E; Mavrogianis, Stanley T; Torres, Jeancarlo; Benevides, Luis A

    2018-05-01

    The U.S. Navy uses the Harshaw 8840/8841 dosimetric (DT-702/PD) system, which employs LiF:Mg,Cu,P thermoluminescent dosimeters (TLDs), developed and produced by Thermo Fisher Scientific (TFS). The dosimeter consists of four LiF:Mg,Cu,P elements, mounted in Teflon® on an aluminum card and placed in a plastic holder. The holder contains a unique filter for each chip made of copper, acrylonitrile butadiene styrene (ABS), Mylar®, and tin. For accredited dosimetry labs, the ISO/IEC 17025:2005(E) requires an acceptance procedure for all new equipment. The Naval Dosimetry Center (NDC) has developed and tested a new non-destructive procedure, which enables the verification and the evaluation of embedded filters in the holders. Testing is based on attenuation measurements of low-energy radiation transmitted through each filter in a representative sample group of holders to verify that the correct filter type and thickness are present. The measured response ratios are then compared with the expected response ratios. In addition, each element's measured response is compared to the mean response of the group. The test was designed and tested to identify significant nonconformities, such as missing copper or tin filters, double copper or double tin filters, or other nonconformities that may impact TLD response ratios. During the implementation of the developed procedure, testing revealed a holder with a double copper filter. To complete the evaluation, the impact of the nonconformities on proficiency testing was examined. The evaluation revealed failures in proficiency testing categories III and IV when these dosimeters were irradiated to high-energy betas.

  4. ADJUSTABLE CHIP HOLDER

    DEFF Research Database (Denmark)

    2009-01-01

    An adjustable microchip holder for holding a microchip is provided having a plurality of displaceable interconnection pads for connecting the connection holes of a microchip with one or more external devices or equipment. The adjustable microchip holder can fit different sizes of microchips...

  5. The U-tube sampling methodology and real-time analysis of geofluids

    International Nuclear Information System (INIS)

    Freifeld, Barry; Perkins, Ernie; Underschultz, James; Boreham, Chris

    2009-01-01

    The U-tube geochemical sampling methodology, an extension of the porous cup technique proposed by Wood (1973), provides minimally contaminated aliquots of multiphase fluids from deep reservoirs and allows for accurate determination of dissolved gas composition. The initial deployment of the U-tube during the Frio Brine Pilot CO 2 storage experiment, Liberty County, Texas, obtained representative samples of brine and supercritical CO 2 from a depth of 1.5 km. A quadrupole mass spectrometer provided real-time analysis of dissolved gas composition. Since the initial demonstration, the U-tube has been deployed for (1) sampling of fluids down gradient of the proposed Yucca Mountain High-Level Waste Repository, Armagosa Valley, Nevada (2) acquiring fluid samples beneath permafrost in Nunuvut Territory, Canada, and (3) at a CO 2 storage demonstration project within a depleted gas reservoir, Otway Basin, Victoria, Australia. The addition of in-line high-pressure pH and EC sensors allows for continuous monitoring of fluid during sample collection. Difficulties have arisen during U-tube sampling, such as blockage of sample lines from naturally occurring waxes or from freezing conditions; however, workarounds such as solvent flushing or heating have been used to address these problems. The U-tube methodology has proven to be robust, and with careful consideration of the constraints and limitations, can provide high quality geochemical samples.

  6. Penetrameter positioner for bore-side radiography of tubes

    International Nuclear Information System (INIS)

    Davis, E.V.; Foster, B.E.

    1983-01-01

    A positioner is provided for placing plaque or wire penetrameters, as used in radiographic inspection, in close proximity with the inner wall of tubing at any desired location along the tubing. The positioner head carrying the penetrameter is inflatable whereby it is positioned in the deflated condition, inflated to place the penetrameter against a weld to be inspected in the tubing wall, and then deflated during removal. If desired, the penetrameter holder may be used to center the radiographic source on the axis of the tube

  7. The U-tube: A new paradigm in borehole fluid sampling

    Energy Technology Data Exchange (ETDEWEB)

    Freifeld, B. M.

    2009-10-01

    Fluid samples from deep boreholes can provide insights into subsurface physical, chemical, and biological conditions. Recovery of intact, minimally altered aliquots of subsurface fluids is required for analysis of aqueous chemistry, isotopic composition, and dissolved gases, and for microbial community characterization. Unfortunately, for many reasons, collecting geofluids poses a number of challenges, from formation contamination by drilling to maintaining integrity during recovery from depths. Not only are there substantial engineering issues in retrieval of a representative sample, but there is often the practical reality that fluid sampling is just one of many activities planned for deep boreholes. The U-tube geochemical sampling system presents a new paradigm for deep borehole fluid sampling. Because the system is small, its ability to integrate with other measurement systems and technologies opens up numerous possibilities for multifunctional integrated wellbore completions. To date, the U-tube has been successfully deployed at four different field sites, each with a different deployment modality, at depths from 260 m to 2 km. While the U-tube has proven to be highly versatile, these installations have resulted in data that provide additional insights for improving future U-tube deployments.

  8. Preset pivotal tool holder

    Science.gov (United States)

    Asmanes, Charles

    1979-01-01

    A tool fixture is provided for precise pre-alignment of a radiused edge cutting tool in a tool holder relative to a fixed reference pivot point established on said holder about which the tool holder may be selectively pivoted relative to the fixture base member to change the contact point of the tool cutting edge with a workpiece while maintaining the precise same tool cutting radius relative to the reference pivot point.

  9. Inert medium (helium) irradiation testing of pressure tube samples

    International Nuclear Information System (INIS)

    Ancuta, M.; Radu, V.; Stefan, V.; Preda, M.

    2001-01-01

    Irradiation tests currently performed in C-5 capsule aim at obtaining data and information concerning behavior to irradiation of pressure tubes of CANDU type fuel channel, to evidence the factors limiting operation life span. A calculation code for analysis and prediction of pressure tube behavior should be based upon periodical inspection results, post irradiation examination of the removed from reactor pressure tubes as well as on the experimental results obtained with materials subjected to irradiation conditions identical with the operational ones. Mechanical behavior analysis should focus both complex thermal-mechanical type stresses and mechanical properties alteration under irradiation. The experimental results should be applied: - to evaluate the irradiation effects upon mechanical properties of Zr-2.5% Nb exposed to fluences up to 10 21 n·cm -2 ; - to gather data concerning the real stress / real deformation characteristic from which characteristic quantities can be deduced as, for instance, elasticity modulus, plasticity modulus, exponent of stress term in the Tsu-Berteles relation, to be used within the CANTUP simulation code describing pressure tube behavior, currently developed at INR Pitesti; - to develop prediction methods of pressure tube behavior and merging with in-service inspection procedure in order to forecast the life span and the proper timing for replacement before major failures occur. The samples irradiated in C-5 capsule were extracted from the ends of Zr-2.5% Nb pressure tubes resulting from Cernavoda NPP Unit 1. The samples for tensile tests were extracted on longitudinal and transversal directions of the pressure tube. The tests were carried out under following conditions: - test environment temperature, 260 - 280 deg.C; - testing medium, helium at 1 - 6 b pressure; - neutron flux (E n > 1 MeV), 1 - 2 · 10 13 ncm -2 s -1 ; - neutron fluence (E n > 1 MeV), 4 · 10 20 ncm -2 . The following characteristics were obtained from tensile

  10. Quality control and enhancement of microwelds for Ir-192 sample holders

    International Nuclear Information System (INIS)

    Lopez, Alcides; Medina, Max; Cavero, Luis

    2013-01-01

    This study shows the micro quality results of tungsten inert gas welds on stainless steel AISI 304 of 5 sample holders for 30 discs by 3 mm diameter and 0.5 mm thick of Ir-192 sources produced in the Radioisotope Production Plant (RPP) of IPEN, generally used in industrial gammagraphy. Macrographic and conventional metallographic analysis were performed to measure the amplitude, thickness and centering parameters of the weld bead, centered data have helped to determine the parameters for welds with good quality, showing defects due to the misaligned glass lens, low magnification image and high visual angle of incidence across the 200 mm security leaded glass giving a low quality weld image due to the low magnification, large chromatic aberration resulting in a weld outside the seam, this problem was solved by changing the old optical visualization system by an external telescope specially designed for this purpose and raising the workbench so that the optical telescope axis and the weld are horizontally, achieving more rapid processes, reliable and reproducible, this new system has proved more convenient, reliable and reproducible. (authors).

  11. Tube closure device, especially for sample irradiation

    International Nuclear Information System (INIS)

    Klahn, F.C.; Nolan, J.H.; Wills, C.

    1979-01-01

    Device for closing the outlet of a bore and temporarily locking components in this bore. Specifically, it concerns a device for closing a tube containing a set of samples for monitoring irradiation in a nuclear reactor [fr

  12. Determination of self shielding factors and gamma attenuation effects for tree ring samples

    International Nuclear Information System (INIS)

    Dagistan Sahin; Kenan Uenlue

    2012-01-01

    Determination of tree ring chemistry using Neutron Activation Analysis (NAA) is part of an ongoing research between Penn State University (PSU) and Cornell University, The Malcolm and Carolyn Wiener Laboratory for Aegean and Near Eastern Dendrochronology. Tree-ring chemistry yields valuable data for environmental event signatures. These signatures are a complex function of elemental concentration. To be certain about concentration of signature elements, it is necessary to perform the measurements and corrections with the lowest error and maximum accuracy possible. Accurate and precise values of energy dependent neutron flux at dry irradiation tubes and detector efficiency for tree ring sample are calculated for Penn State Breazeale Reactor (PSBR). For the calculation of energy dependent and self shielding corrected neutron flux, detailed model of the TRIGA Mark III reactor at PSU with updated fuel compositions was prepared using the MCNP utility for reactor evolution (MURE) libraries. Dry irradiation tube, sample holder and sample were also included in the model. The thermal flux self-shielding correction factors due to the sample holder and sample for were calculated and verified with previously published values. The Geant-4 model of the gamma spectroscopy system, developed at Radiation Science and Engineering Center (RSEC), was improved and absolute detector efficiency for tree-ring samples was calculated. (author)

  13. An X-ray diffractometer specimen holder for use with reactive and toxic materials

    International Nuclear Information System (INIS)

    Huyton, A.; Munden, A.B.

    1979-04-01

    An X-ray diffractometer specimen holder has been designed for analysis of reactive sodium compounds which will satisfactorily seal the sample from the atmosphere. The holder can be readily filled in a glove-box and is easily transported for mounting on a vertical Philips PW 1051 X-ray diffractometer. It is considered that this holder could also be applied to a wide range of other reactive and toxic materials, e.g. plutonium or its compounds. (author)

  14. Ebola Virus and Marburg Virus in Human Milk Are Inactivated by Holder Pasteurization.

    Science.gov (United States)

    Hamilton Spence, Erin; Huff, Monica; Shattuck, Karen; Vickers, Amy; Yun, Nadezda; Paessler, Slobodan

    2017-05-01

    Potential donors of human milk are screened for Ebola virus (EBOV) using standard questions, but testing for EBOV and Marburg virus (MARV) is not part of routine serological testing performed by milk banks. Research aim: This study tested the hypothesis that EBOV would be inactivated in donor human milk (DHM) by standard pasteurization techniques (Holder) used in all North American nonprofit milk banks. Milk samples were obtained from a nonprofit milk bank. They were inoculated with EBOV (Zaire strain) and MARV (Angola strain) and processed by standard Holder pasteurization technique. Plaque assays for EBOV and MARV were performed to detect the presence of virus after pasteurization. Neither EBOV nor MARV was detectable by viral plaque assay in DHM or culture media samples, which were pasteurized by the Holder process. EBOV and MARV are safely inactivated in human milk by standard Holder pasteurization technique. Screening for EBOV or MARV beyond questionnaire and self-deferral is not needed to ensure safety of DHM for high-risk infants.

  15. Evaluation of sampling plans for in-service inspection of steam generator tubes

    International Nuclear Information System (INIS)

    Kurtz, R.J.; Heasler, P.G.; Baird, D.B.

    1994-02-01

    This report summarizes the results of three previous studies to evaluate and compare the effectiveness of sampling plans for steam generator tube inspections. An analytical evaluation and Monte Carlo simulation techniques were the methods used to evaluate sampling plan performance. To test the performance of candidate sampling plans under a variety of conditions, ranges of inspection system reliability were considered along with different distributions of tube degradation. Results from the eddy current reliability studies performed with the retired-from-service Surry 2A steam generator were utilized to guide the selection of appropriate probability of detection and flaw sizing models for use in the analysis. Different distributions of tube degradation were selected to span the range of conditions that might exist in operating steam generators. The principal means of evaluating sampling performance was to determine the effectiveness of the sampling plan for detecting and plugging defective tubes. A summary of key results from the eddy current reliability studies is presented. The analytical and Monte Carlo simulation analyses are discussed along with a synopsis of key results and conclusions

  16. Preparation and characterization of porous Mg-Zn-Ca alloy by space holder technique

    Science.gov (United States)

    Annur, D.; Lestari, Franciska P.; Erryani, A.; Sijabat, Fernando A.; G. P. Astawa, I. N.; Kartika, I.

    2018-04-01

    Magnesium had been recently researched as a future biodegradable implant material. In the recent study, porous Mg-Zn-Ca alloys were developed using space holder technique in powder metallurgy process. Carbamide (10-20%wt) was added into Mg-6Zn-1Ca (in wt%) alloy system as a space holder to create porous structure material. Sintering process was done in a tube furnace under Argon atmosphere in 610 °C for 5 hours. Porous structure of the resulted alloy was examined using Scanning Electron Microscope (SEM), while the phase formation was characterized by X-ray diffraction analysis (XRD). Further, mechanical properties of porous Mg-Zn-Ca alloy was examined through compression testing. Microstructure characterization showed higher content of Carbamide in the alloy would give different type of pores. However, compression test showed that mechanical properties of Mg-Zn-Ca alloy would decrease significantly when higher content of carbamide was added.

  17. Probing electronic interactions using electron tunneling

    Indian Academy of Sciences (India)

    pratap

    Sample preparation. Chamber. Sample manipulators. Vibration Isolation. Table. Cryostat. Load lock. STM Head. Magnet. Sample holder. Tip. Tip holder. Piezo electric tube. Coarse positioner. Macor. Cu housing for sample holder. PCB. Cu shielding can. Steel studs. Our Toy: The TIFR milli-Kelvin STM. Lowest temperature:.

  18. 19 CFR 10.7 - Substantial containers or holders.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Substantial containers or holders. 10.7 Section 10... Exported and Returned § 10.7 Substantial containers or holders. (a) Substantial containers or holders... domestic products exported and returned. When such containers or holders are imported not containing or...

  19. Considerations on sample holder design and custom-made non-polarizable electrodes for Spectral Induced Polarization measurements on unsaturated soils

    Science.gov (United States)

    Kaouane, C.; Chouteau, M. C.; Fauchard, C.; Cote, P.

    2014-12-01

    Spectral Induced Polarization (SIP) is a geophysical method sensitive to water content, saturation and grain size distribution. It could be used as an alternative to nuclear probes to assess the compaction of soils in road works. To evaluate the potential of SIP as a practical tool, we designed an experiment for complex conductivity measurements on unsaturated soil samples.Literature presents a large variety of sample holders and designs, each depending on the context. Although we might find some precise description about the sample holder, exact replication is not always possible. Furthermore, the potential measurements are often done using custom-made Ag/AgCl electrodes and very few indications are given on their reliability with time and temperature. Our objective is to perform complex conductivity measurements on soil samples compacted in a PVC cylindrical mould (10 cm-long, 5 cm-diameter) according to geotechnical standards. To expect homogeneous current density, electrical current is transmitted through the sample via chambers filled with agar gel. Agar gel is a good non-polarizable conductor within the frequency range (1 mHz -20kHz). Its electrical properties are slightly known. We measured increasing of agar-agar electrical conductivity in time. We modelled the influence of this variation on the measurement. If the electrodes are located on the sample, it is minimized. Because of the dimensions at stake and the need for simple design, potential electrodes are located outside the sample, hence the gel contributes to the measurements. Since the gel is fairly conductive, we expect to overestimate the sample conductivity. Potential electrodes are non-polarizable Ag/AgCl electrodes. To avoid any leakage, the KCl solution in the electrodes is replaced by saturated KCl-agar gel. These electrodes are low cost and show a low, stable, self-potential (<1mV). In addition, the technique of making electrode can be easily reproduced and storage and maintenance are simple

  20. Diffeomorphisms Holder conjugate to Anosov diffeomorphisms

    OpenAIRE

    Gogolev, Andrey

    2008-01-01

    We show by means of a counterexample that a $C^{1+Lip}$ diffeomorphism Holder conjugate to an Anosov diffeomorphism is not necessarily Anosov. The counterexample can bear higher smoothness up to $C^3$. Also we include a result from the 2006 Ph.D. thesis of T. Fisher: a $C^{1+Lip}$ diffeomorphism Holder conjugate to an Anosov diffeomorphism is Anosov itself provided that Holder exponents of the conjugacy and its inverse are sufficiently large.

  1. Controlled chloride cracking of austenitic stainless steel tube samples

    OpenAIRE

    Raseroka, M.S.; Pistorius, P.C.

    2009-01-01

    An experimental rig has been constructed to produce chloride stress corrosion cracks in Type 304L stainless steel tube samples. The samples are to be used to test possible in situ repair methods in future work. The factor which influences the time to failure most strongly is the sample temperature; the distribution of cracks within the sample is affected by local temperature variations and by the position of the water line. Low-frequency oscillations in stress, caused by the on-off temperatur...

  2. Tubing For Sampling Hydrazine Vapor

    Science.gov (United States)

    Travis, Josh; Taffe, Patricia S.; Rose-Pehrsson, Susan L.; Wyatt, Jeffrey R.

    1993-01-01

    Report evaluates flexible tubing used for transporting such hypergolic vapors as those of hydrazines for quantitative analysis. Describes experiments in which variety of tubing materials, chosen for their known compatibility with hydrazine, flexibility, and resistance to heat.

  3. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?

    Science.gov (United States)

    Phelan, Michael P; Reineks, Edmunds Z; Hustey, Fredric M; Berriochoa, Jacob P; Podolsky, Seth R; Meldon, Stephen; Schold, Jesse D; Chamberlin, Janelle; Procop, Gary W

    2016-09-01

    Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest(®)) for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]). Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99]) or mild (10.3% vs 9.8% [p=0.88]) hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%-14.6%). We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material). Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department.

  4. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?

    Directory of Open Access Journals (Sweden)

    Fredric M. Hustey

    2016-09-01

    Full Text Available Introduction: Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. Methods: The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest® for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. Results: During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]. Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99] or mild (10.3% vs 9.8% [p=0.88] hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%–14.6%. Conclusion: We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material. Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department.

  5. Determination of low concentrations of uranium in granite samples by X-ray fluorescence

    International Nuclear Information System (INIS)

    Roca, M.; Diaz-Guerra, J.P.

    1981-01-01

    An x-ray fluorescence method for the determination of uranium in granite samples for concentrations ranging from 3 to 100 ppm U 3 O 8 has been developed. To this purpose a sample holder, specially designed, allowing the irradiation of sample surfaces 42.5 mm in diameter and a molybdenum tube operating with a power of 2700 W (90 kV, 30 mA) are used. The background influence and the spectral interferences from rubidium and strontium have been taken into account and specific correction coefficients have been computed. A Basic program facilitates the report of the analytical results. (author)

  6. National Recordal System IK holder catalogue process

    CSIR Research Space (South Africa)

    Pretorius, R

    2012-10-01

    Full Text Available good, based on IK.? Subsequently, the South African Department of Science and Technology (DST) created a National Indigenous Knowledge Systems Office (NIKSO) that is taking the lead on interfacing IKS with other recognised knowledge holders... is to illustrate the South African National Recordal Systems (NRS) process whereby Indigenous Knowledge (IK) holder?s information is captured in a registry, as specified in South Africa?s Indigenous Knowledge Systems (IKS) Policy, through an IK cataloguing...

  7. Simple and versatile turbidimetric monitoring of bacterial growth in liquid cultures using a customized 3D printed culture tube holder and a miniaturized spectrophotometer: application to facultative and strictly anaerobic bacteria

    Directory of Open Access Journals (Sweden)

    Margarida R. G. Maia

    2016-08-01

    Full Text Available Here we introduce a novel strategy for turbidimetric monitoring of bacterial growth in liquid culture. The instrumentation comprises a light source, a customized 3D printed culture tube holder and a miniaturized spectrophotometer, connected through optical cables. Due to its small footprint and the possibility to operate with external light, bacterial growth was directly monitored from culture tubes in a simple and versatile fashion. This new portable measurement technique was used to monitor the growth of facultative (Escherichia coli ATCC/25922, and Staphylococcus aureus ATCC/29213 and strictly (Butyrivibrio fibrisolvens JW11, Butyrivibrio proteoclasticus P18, and Propionibacterium acnes DSMZ 1897 anaerobic bacteria. For E. coli and S. aureus, the growth rates calculated from normalized optical density values were compared with those ones obtained using a benchtop spectrophotometer without significant differences (P = 0.256. For the strictly anaerobic species, a high precision (RSD < 3.5% was observed between replicates up to 48 h. Regarding its potential for customization, this manifold could accommodate further developments for customized turbidimetric monitoring, such as the use of light-emitting diodes as a light source or flow cells.

  8. Simple and Versatile Turbidimetric Monitoring of Bacterial Growth in Liquid Cultures Using a Customized 3D Printed Culture Tube Holder and a Miniaturized Spectrophotometer: Application to Facultative and Strictly Anaerobic Bacteria.

    Science.gov (United States)

    Maia, Margarida R G; Marques, Sara; Cabrita, Ana R J; Wallace, R John; Thompson, Gertrude; Fonseca, António J M; Oliveira, Hugo M

    2016-01-01

    Here we introduce a novel strategy for turbidimetric monitoring of bacterial growth in liquid culture. The instrumentation comprises a light source, a customized 3D printed culture tube holder and a miniaturized spectrophotometer, connected through optical cables. Due to its small footprint and the possibility to operate with external light, bacterial growth was directly monitored from culture tubes in a simple and versatile fashion. This new portable measurement technique was used to monitor the growth of facultative (Escherichia coli ATCC/25922, and Staphylococcus aureus ATCC/29213) and strictly (Butyrivibrio fibrisolvens JW11, Butyrivibrio proteoclasticus P18, and Propionibacterium acnes DSMZ 1897) anaerobic bacteria. For E. coli and S. aureus, the growth rates calculated from normalized optical density values were compared with those ones obtained using a benchtop spectrophotometer without significant differences (P = 0.256). For the strictly anaerobic species, a high precision (relative standard deviation < 3.5%) was observed between replicates up to 48 h. Regarding its potential for customization, this manifold could accommodate further developments for customized turbidimetric monitoring, such as the use of light-emitting diodes as a light source or flow cells.

  9. Successive measurements of streaming potential and electroosmotic pressure with the same core-holder

    Science.gov (United States)

    Yin, Chenggang; Hu, Hengshan; Yu, Chunhao; Wang, Jun

    2018-05-01

    Successive measurements of the streaming potential and electroosmotic pressure of each core sample are important for understanding the mechanisms of electrokinetic effects. In previous studies, one plug of the core-holder needs to be replaced in these two experiments, which causes the change of the fluid parameters and the boundary conditions in the core. We design a new core-holder to permit successive experiments without plug replacement, which ensures the consistency of the measurement environment. A two-direction harmonic pressure-driving source is accordingly designed. Using this new equipment, electrokinetic experiments conducted ten core samples at 0.4 mol/L NaCl solution. The results show good agreement between the electrokinetically deduced permeability and premeasured gas permeability. For high salinity saturated samples, the permeability can be inverted from electroosmotic effect instead of the streaming potential.

  10. Selectivity and limitations of carbon sorption tubes for capturing siloxanes in biogas during field sampling.

    Science.gov (United States)

    Tansel, Berrin; Surita, Sharon C

    2016-06-01

    Siloxane levels in biogas can jeopardize the warranties of the engines used at the biogas to energy facilities. The chemical structure of siloxanes consists of silicon and oxygen atoms, alternating in position, with hydrocarbon groups attached to the silicon side chain. Siloxanes can be either in cyclic (D) or linear (L) configuration and referred with a letter corresponding to their structure followed by a number corresponding to the number of silicon atoms present. When siloxanes are burned, the hydrocarbon fraction is lost and silicon is converted to silicates. The purpose of this study was to evaluate the adequacy of activated carbon gas samplers for quantitative analysis of siloxanes in biogas samples. Biogas samples were collected from a landfill and an anaerobic digester using multiple carbon sorbent tubes assembled in series. One set of samples was collected for 30min (sampling 6-L gas), and the second set was collected for 60min (sampling 12-L gas). Carbon particles were thermally desorbed and analyzed by Gas Chromatography Mass Spectrometry (GC/MS). The results showed that biogas sampling using a single tube would not adequately capture octamethyltrisiloxane (L3), hexamethylcyclotrisiloxane (D3), octamethylcyclotetrasiloxane (D4), decamethylcyclopentasiloxane (D5) and dodecamethylcyclohexasiloxane (D6). Even with 4 tubes were used in series, D5 was not captured effectively. The single sorbent tube sampling method was adequate only for capturing trimethylsilanol (TMS) and hexamethyldisiloxane (L2). Affinity of siloxanes for activated carbon decreased with increasing molecular weight. Using multiple carbon sorbent tubes in series can be an appropriate method for developing a standard procedure for determining siloxane levels for low molecular weight siloxanes (up to D3). Appropriate quality assurance and quality control procedures should be developed for adequately quantifying the levels of the higher molecular weight siloxanes in biogas with sorbent tubes

  11. Harmonising and Matching IPR Holders at IP Australia

    OpenAIRE

    T’Mir D. Julius; Gaétan de Rassenfosse

    2014-01-01

    This document describes the methodology developed by the Melbourne Institute to: (i) harmonise holders of intellectual property rights (IPRs) at IP Australia (applications for patent, designs, trademarks and plant breeder’s rights); (ii) match Australian IPRs holders to the Australian business register; (iii) identify the ultimate owners within Australia; and (iv) identify which holders are small and medium size enterprises.

  12. Development and Application of a Sample Holder for In Situ Gaseous TEM Studies of Membrane Electrode Assemblies for Polymer Electrolyte Fuel Cells.

    Science.gov (United States)

    Kamino, Takeo; Yaguchi, Toshie; Shimizu, Takahiro

    2017-10-01

    Polymer electrolyte fuel cells hold great potential for stationary and mobile applications due to high power density and low operating temperature. However, the structural changes during electrochemical reactions are not well understood. In this article, we detail the development of the sample holder equipped with gas injectors and electric conductors and its application to a membrane electrode assembly of a polymer electrolyte fuel cell. Hydrogen and oxygen gases were simultaneously sprayed on the surfaces of the anode and cathode catalysts of the membrane electrode assembly sample, respectively, and observation of the structural changes in the catalysts were simultaneously carried out along with measurement of the generated voltages.

  13. Stability of Cortisol and Cortisone in Human Breast Milk During Holder Pasteurization.

    Science.gov (United States)

    van der Voorn, Bibian; de Waard, Marita; Dijkstra, Lisette R; Heijboer, Annemieke C; Rotteveel, Joost; van Goudoever, Johannes B; Finken, Martijn J J

    2017-12-01

    Human donor milk is the feeding of choice for preterm infants, when own mother's milk is not available. Holder pasteurization is necessary to secure the safety of donor milk, although it can affect milk quality by reduction of nutritional and bioactive components. Recently, research has focused on the potential role of breast milk glucocorticoids for infant development. At this moment, it is unknown whether pasteurization affects milk glucocorticoid levels. Therefore, we assessed whether Holder pasteurization, the most frequently used method nowadays, reduces breast milk cortisol and cortisone levels, using breast milk samples from 30 women who delivered at term. We found tight correlations between pre- and postpasteurization levels of cortisol (R = 0.99) and cortisone (R = 0.98), and good agreement in Passing and Bablok regression analysis. In conclusion, cortisol and cortisone in human term breast milk are not significantly affected by Holder pasteurization.

  14. Head-positioning scintillation camera and head holder therefor

    International Nuclear Information System (INIS)

    Kay, T.D.

    1976-01-01

    A holder for immobilizing the head of a patient undergoing a vertex brain scan by a Gamma Scintillation Camera is described. The holder has a uniquely designed shape capable of comfortably supporting the head. In addition, this holder can be both adjustably and removably utilized in combination with the scintillation camera so as to enable the brain scan operation to take place while the patient is in the seated position

  15. Effects of Holder pasteurization on the protein profile of human milk.

    Science.gov (United States)

    Peila, Chiara; Coscia, Alessandra; Bertino, Enrico; Cavaletto, Maria; Spertino, Stefano; Icardi, Sara; Tortone, Claudia; Visser, Gerard H A; Gazzolo, Diego

    2016-04-07

    The most widespread method for the treatment of donor milk is the Holder pasteurization (HoP). The available literature data show that HoP may cause degradation of some bioactive components. The aim of this study was to determine the effect of HoP on the protein profile of human milk (HM) using a GeLC-MS method, a proteomic approach and a promising technique able to offer a qualitative HM protein profile. HM samples were collected by standardized methods from 20 mothers carrying both preterm and term newborns. A aliquot of each sample was immediately frozen at -80 °C, whilst another one was Holder pasteurized and then frozen. All samples were then analyzed by GeLC-MS. The protein bands of interest were excised from the gel, digested with trypsin and identified by nano-HPLC-MS/MS analysis. The protein profile before and after HoP showed qualitative differences only in 6 samples out of 20, while in the remaining 14 no detectable differences were found. The differences interested only colostrums and transitional milk samples and regarded the decrease of the electrophoretic bands corresponding to alpha and beta-casein, tenascin, lactoferrin and immunoglobulin. In the majority of samples, HoP did not cause any modification, thereby preserving the biological activity of HM proteins.

  16. Continuous Passive Sampling of Solutes from Agricultural Subsurface Drainage Tubes

    Science.gov (United States)

    Lindblad Vendelboe, Anders; de Jonge, Hubert; Rozemeijer, Joachim; Wollesen de Jonge, Lis

    2015-04-01

    Agricultural subsurface tube drain systems play an important role in water and solute transport. One study, focusing on lowland agricultural catchments, showed that subsurface tube drainage contributed up to 80% of the annual discharge and 90% of the annual NO3 load from agricultural fields to the receiving water bodies. Knowledge of e.g. nutrient loads and drainage volumes, based on measurements and modelling, are important for adequate water quality management. Despite the importance of tube drain transport of solutes, monitoring data are scarce. This scarcity is a result of the existing monitoring techniques for flow and contaminant load from tube drains being expensive and labor-extensive. The study presented here aimed at developing a cheap, simple, and robust method to monitor solute loads from tube drains. The method is based on the newly developed Flowcap, which can be attached to existing tube drain outlets and can measure total flow, contaminant load and flow-averaged concentrations of solutes in the drainage. The Flowcap builds on the existing Sorbicell principle, a passive sampling system that measures average concentrations over longer periods of time (days to months) for various compounds. The Sorbicell consists of two compartments permeable to water. One compartment contains an adsorbent and one contains a tracer. When water passes through the Sorbicell the compound of interest is absorbed while a tracer is released. Using the tracer loss to calculate the volume of water that has passed the Sorbicell it is possible to calculate the average concentration of the compound. When mounting Sorbicells in the Flowcap, a flow-proportional part of the drainage is sampled from the main stream. To accommodate the wide range of drainage flow rates two Flowcaps with different capacities were tested in the laboratory: one with a capacity of 25 L min-1 (Q25) and one with a capacity of 256 L min-1 (Q256). In addition, Sorbicells with two different hydraulic

  17. Apparatus for sectioning demountable semiconductor samples

    Science.gov (United States)

    Sopori, B.L.; Wolf, A.

    1984-01-01

    Apparatus for use during polishing and sectioning operations of a ribbon sample is described. The sample holder includes a cylinder having an axially extending sample cavity terminated in a first funnel-shaped opening and a second slot-like opening. A spring-loaded pressure plunger is located adjacent the second opening of the sample cavity for frictional engagement of the sample cavity. A heat softenable molding medium is inserted in the funnel-shaped opening, to surround the sample. After polishing, the heater is energized to allow draining of the molding medium from the sample cavity. During manual polishing, the second end of the sample holder is inserted in a support ring which provides mechanical support as well as alignment of the sample holder during polishing. A gauge block for measuring the protrusion of a sample beyond the second wall of the holder is also disclosed.

  18. Low conductive support for thermal insulation of a sample holder of a variable temperature scanning tunneling microscope.

    Science.gov (United States)

    Hanzelka, Pavel; Vonka, Jakub; Musilova, Vera

    2013-08-01

    We have designed a supporting system to fix a sample holder of a scanning tunneling microscope in an UHV chamber at room temperature. The microscope will operate down to a temperature of 20 K. Low thermal conductance, high mechanical stiffness, and small dimensions are the main features of the supporting system. Three sets of four glass balls placed in vertices of a tetrahedron are used for thermal insulation based on small contact areas between the glass balls. We have analyzed the thermal conductivity of the contacts between the balls mutually and between a ball and a metallic plate while the results have been applied to the entire support. The calculation based on a simple model of the setup has been verified with some experimental measurements. In comparison with other feasible supporting structures, the designed support has the lowest thermal conductance.

  19. 38 CFR 36.4341 - Death or insolvency of holder.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Death or insolvency of... Death or insolvency of holder. (a) Immediately upon the death of the holder and without the necessity of... applicable in the event of: (1) Insolvency of holder; (2) Initiation of any bankruptcy or reorganization, or...

  20. 21 CFR 882.4460 - Neurosurgical head holder (skull clamp).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical head holder (skull clamp). 882.4460... holder (skull clamp). (a) Identification. A neurosurgical head holder (skull clamp) is a device used to clamp the patient's skull to hold head and neck in a particular position during surgical procedures. (b...

  1. Effect of temperature on the breakthrough of a charcoal tube during vinyl chloride monomer sampling.

    Science.gov (United States)

    Roh, J; Park, Y J; Kim, C N; Lim, N G; Lee, S H; Song, J S; Won, J U; Talaska, G

    2000-01-01

    This study evaluated the effects of temperature on breakthrough of two standard collection media at various concentrations during vinyl chloride monomer (VCM) sampling. The National Institute for Occupational Safety and Health (NIOSH) and Occupational Safety and Health Administration (OSHA) methods were evaluated. To determine whether breakthrough of VCM would occur at the extremes of exposure and temperature that might be encountered in some workplaces, air samples containing 4 ppm (10.24 mg/m3), 8 ppm (20.45 mg/m3), 16 ppm (40.98 mg/m3), and 32 ppm (81.80 mg/m3) of VCM were collected at temperatures of 4, 22, and 40 degrees C. Five liters of air was sampled at the rate of 0.05 L/min for 100 min using the activated charcoal tube recommended by NIOSH. A second tube was added to the sampling train to collect any VCM that might not have been absorbed in the first tube. To collect VCM air samples by the OSHA method, two carbon molecular sieve tubes were connected serially and 3 L of air was sampled at the rate of 0.05 L/min for 60 min. A gas chromatograph with a flame ionization detector and ultra 2 capillary column was used to analyze VCM. Significant breakthrough was found when sampling at higher temperatures with the NIOSH method. No breakthrough was found when samples were collected using the OSHA media at different temperatures and concentrations. Therefore, under hot ambient conditions (>22 degrees C), the possibility of breakthrough should be considered when sampling VCM by the NIOSH method.

  2. A tube seepage meter for in situ measurement of seepage rate and groundwater sampling

    Science.gov (United States)

    Solder, John; Gilmore, Troy E.; Genereux, David P.; Solomon, D. Kip

    2016-01-01

    We designed and evaluated a “tube seepage meter” for point measurements of vertical seepage rates (q), collecting groundwater samples, and estimating vertical hydraulic conductivity (K) in streambeds. Laboratory testing in artificial streambeds show that seepage rates from the tube seepage meter agreed well with expected values. Results of field testing of the tube seepage meter in a sandy-bottom stream with a mean seepage rate of about 0.5 m/day agreed well with Darcian estimates (vertical hydraulic conductivity times head gradient) when averaged over multiple measurements. The uncertainties in q and K were evaluated with a Monte Carlo method and are typically 20% and 60%, respectively, for field data, and depend on the magnitude of the hydraulic gradient and the uncertainty in head measurements. The primary advantages of the tube seepage meter are its small footprint, concurrent and colocated assessments of q and K, and that it can also be configured as a self-purging groundwater-sampling device.

  3. Ergonomic design and evaluation of a diagnostic ultrasound transducer holder.

    Science.gov (United States)

    Ghasemi, Mohamad Sadegh; Hosseinzadeh, Payam; Zamani, Farhad; Ahmadpoor, Hossein; Dehghan, Naser

    2017-12-01

    Work-related musculoskeletal disorders (WMSDs) are injuries and disorders that affect the body's movement and musculoskeletal system. Awkward postures represent one of the major ergonomic risk factors that cause WMSDs among sonographers while working with an ultrasound transducer. This study aimed to design and evaluate a new holder for the ultrasound transducer. In the first phase a new holder was designed for the transducer, considering design principles. Evaluation of the new holder was then carried out by electrogoniometry and a locally perceived discomfort (LPD) scale. The application of design principles to the new holder resulted in an improvement of wrist posture and comfort. Wrist angles in extension, flexion, radial deviation and ulnar deviation were lower with utilization of the new holder. The severity of discomfort based on the LPD method in the two modes of work with and without the new holder was reported with values of 1.3 and 1.8, respectively (p ergonomics design principles was effective in minimizing wrist deviation and increasing comfort while working with the new holder.

  4. Holder pasteurization affects S100B concentrations in human milk.

    Science.gov (United States)

    Peila, Chiara; Coscia, Alessandra; Bertino, Enrico; Li Volti, Giovanni; Galvano, Fabio; Visser, Gerard H A; Gazzolo, Diego

    2018-02-01

    Donor milk (DM) represents an important nutrition source for high-risk newborns. Holder pasteurization (HoP) is the most recommended procedure for DM treatment, providing a good compromise between microbiological safety and biological quality. HoP was previously shown to affect DM cytokines, growth factors and hormones levels, whilst no data concerning the possible effects of HoP on neurobiomarkers (NB) are available. Therefore, our study investigated whether the concentration in DM of a well-known NB involved in brain development/damage, namely S100B, changes due to HoP. We conducted a pretest-test study in 11 mothers, whose DM samples were sub-divided into two parts: the first was immediately frozen (-80 °C); the second was pasteurized with Holder method before freezing. S100B DM levels were measured using a commercially available immunoluminometric assay. S100B protein was detected in all milk samples. Results showed significant differences between groups (p pasteurization stresses and the need to develop new storage techniques to preserve the biological quality of human milk.

  5. 12 CFR 569.3 - Holders of proxies.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Holders of proxies. 569.3 Section 569.3 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY PROXIES § 569.3 Holders of proxies. No proxy of a mutual savings association with a term greater than eleven months or solicited at...

  6. Zaria Universal Oxygenator Holder phase I

    Directory of Open Access Journals (Sweden)

    Sunday Adoga Edaigbini

    2014-01-01

    Full Text Available Introduction: The conduct of cardiopulmonary bypass surgery requires the use of equipment and devices like the oxygenator. The oxygenator comes in different makes and each manufacturer customizes the carrier or ′holder′ of this device specific to their design. Aim: This paper presents an innovation designed to overcome the need to purchase a different holder for every oxygenator thereby cutting the cost. Materials and Methods: A sheet of iron measuring 1.9 cm (width × 0.1 cm (thickness was used to design the holder circular main frame. Another sheet measuring 2 cm (width × 0.6 cm (thickness × 24 cm (length was used to construct a V-shaped handle with the arms of the V attached to the main frame 7 cm apart. At the narrow base of the handle is a latch requiring two 13-gauge screws to attach the holder to the heart-lung machine. Within the circumference of the main frame are four T-shaped side arms which grip the oxygenator; located at 2, 5, 7 and 11 O′clock positions. The stem of the T consist of a 0.6 cm (thickness × 13 cm (length rod drilled through the main frame. The cross of the T consists of variable lengths of the same sheet as the mainframe attached to the stem by a screw mechanism. At the base of the T, is attached a circular handle (4 cm in diameter made of 0.4 cm iron rod. Result: An oxygenator holder which weighs 1.75 kg with a total length of 54 cm (the diameter of the mainframe is 30 cm. Its advantages include (i affordability, (ii materials are locally accessible, (iii versatility (iv reproducibility. The disadvantages include, (i it requires some time to fit, (ii caution is required in fitting the oxygenator to avoid breakage, (iii a spanner is required to lock the latch. Conclusion: The concept of a universal holder is pertinent, especially in resource poor environments to avoid purchasing a new holder whenever the usual oxygenator common to the centre is unavailable. This device is amenable to further modifications to

  7. Lexan Linear Shaped Charge Holder with Magnets and Backing Plate

    Science.gov (United States)

    Maples, Matthew W.; Dutton, Maureen L.; Hacker, Scott C.; Dean, Richard J.; Kidd, Nicholas; Long, Chris; Hicks, Robert C.

    2013-01-01

    A method was developed for cutting a fabric structural member in an inflatable module, without damaging the internal structure of the module, using linear shaped charge. Lexan and magnets are used in a charge holder to precisely position the linear shaped charge over the desired cut area. Two types of charge holders have been designed, each with its own backing plate. One holder cuts fabric straps in the vertical configuration, and the other charge holder cuts fabric straps in the horizontal configuration.

  8. Fatigue testing on samples from Zircaloy-4 tubes type SEU-43

    International Nuclear Information System (INIS)

    Olaru, V.; Ionescu, V.; Nitu, A.; Ionescu, D.; Voicu, F.

    2016-01-01

    The paper presents the testing of samples worked from Zicaloy-4 tubes (as-received.. metallurgical state), utilized in the composition of the CANDU SEU-43 fuel bundle. These tests are intended to simulate their behaviour in a power cycling process inside the reactor. The testing process is of low cycle fatigue type, done outside of the reactor, on ''C-ring'' samples, cut along the transversal direction. These samples are tested at 1%, 2% and 3% amplitude deformation, at room temperature. The calibration curves for both types of tube (small and big diameter) are determined by using the finite element analyses with the ANSYS computer code. The cycling test results are in the form of a fatigue life curve (N-e) for zircaloy-4 used in the SEU-43 fuel bundle. The curve is determined by the experimental dependency between the number of cycles to fracture and the deformation amplitude. The low cycle fatigue mechanical tests done at room temperature together with electronic microscopy analyses have reflected the characteristic behaviour of the zircaloy-4 metal in the given environment conditions. (authors)

  9. Evaluation of stomach tubes and gastric lavage for sampling diets from blue catfish and flathead catfish

    Science.gov (United States)

    Waters, D.S.; Kwak, T.J.; Arnott, J.B.; Pine, William E.

    2004-01-01

    We compared the ability to extract all stomach contents by using stomach tubes or gastric lavage to sample diets from blue catfish Ictalurus furcatus and flathead catfish Pylodictus olivarus. Pulsed gastric lavage (PGL) removed a significantly greater proportion of stomach content mass (95.6%) from blue catfish than did stomach tubes (14.6%). Percent mass of flathead catfish contents removed with PGL (96.0%) was not significantly different from that removed with stomach tubes (86.9%). Based on the greater effectiveness of PGL for blue catfish, combined with a shorter mean time required per sample (69 versus 118 s) and the better preservation of extracted diet material, we recommend using PGL as a nonlethal technique to collect diet samples from large catfishes.

  10. Introduction of sample tubes with sodium azide as a preservative for ethyl glucuronide in urine.

    Science.gov (United States)

    Luginbühl, Marc; Weinmann, Wolfgang; Al-Ahmad, Ali

    2017-09-01

    Ethyl glucuronide (EtG) is a direct alcohol marker, which is widely used for clinical and forensic applications, mainly for abstinence control. However, the instability of EtG in urine against bacterial degradation or the post-collectional synthesis of EtG in contaminated samples may cause false interpretation of EtG results in urine samples. This study evaluates the potential of sodium azide in tubes used for urine collection to hinder degradation of ethyl glucuronide by bacterial metabolism taking place during growth of bacterial colonies. The tubes are part of a commercial oral fluid collection device. The sampling system was tested with different gram-positive and gram-negative bacterial species previously observed in urinary tract infections, such as Escherichia coli, Staphylococcus aureus, Enterecoccus faecalis, Staphylococcus epidermidis, Klebsiella pneumoniae, Enterobacter cloacae, and Pseudomonas aeruginosa. Inhibition of bacterial growth by sodium azide, resulting in lower numbers of colony forming units compared to control samples, was observed for all tested bacterial species. To test the prevention of EtG degradation by the predominant pathogen in urinary tract infection, sterile-filtered urine and deficient medium were spiked with EtG, and inoculated with E. coli prior to incubation for 4 days at 37 °C in tubes with and without sodium azide. Samples were collected every 24 hours, during four consecutive days, whereby the colony forming units (CFU) were counted on Columbia blood agar plates, and EtG was analyzed by LC-MS/MS. As expected, EtG degradation was observed when standard polypropylene tubes were used for the storage of contaminated samples. However, urine specimens collected in sodium azide tubes showed no or very limited bacterial growth and no EtG degradation. As a conclusion, sodium azide is useful to reduce bacterial growth of gram-negative and gram-positive bacteria. It inhibits the degradation of EtG by E. coli and can be used for

  11. Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems.

    Science.gov (United States)

    Mullins, Garrett R; Bruns, David E

    2017-10-01

    Transport of blood samples through pneumatic tube systems (PTSs) generates air bubbles in transported blood samples and, with increasing duration of transport, the appearance of hemolysis. We investigated the role of air-bubble formation in PTS-induced hemolysis. Air was introduced into blood samples for 0, 1, 3 or 5min to form air bubbles. Hemolysis in the blood was assessed by (H)-index, lactate dehydrogenase (LD) and potassium in plasma. In an effort to prevent PTS-induced hemolysis, blood sample tubes were completely filled, to prevent air bubble formation, and compared with partially filled samples after PTS transport. We also compared hemolysis in anticoagulated vs clotted blood subjected to PTS transport. As with transport through PTSs, the duration of air bubble formation in blood by a gentle stream of air predicted the extent of hemolysis as measured by H-index (pair space in a blood sample prevented bubble formation and fully protected the blood from PTS-induced hemolysis (ptransport and was partially protected from hemolysis vs anticoagulated blood as indicated by lower LD (ptransport. Prevention of air bubble formation in blood samples during PTS transport protects samples from hemolysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Hydrogen concentration determination in pressure tube samples using differential scanning calorimetry (dsc)

    International Nuclear Information System (INIS)

    Marinescu, R.; Mincu, M.

    2015-01-01

    Zirconium alloys are widely used as a structural material in nuclear reactors. It is known that zirconium based cladding alloys absorb hydrogen as a result of service in a pressurized water reactor. Hydrogen absorbed (during operation of the reactor) in the zirconium alloy, out of which the pressure tube is made, is one of the major factors determining the life time of the pressure tube. For monitoring the hydrides, samples of the pressure tube are periodically taken and analyzed. At normal reactor operating temperature, hydrogen has limited solubility in the zirconium lattice and precipitates out of solid solution as zirconium hydride when the solid solubility is exceeded. As a consequences material characterization of Zr-2.5Nb CANDU pressure tubes is required after manufacturing but also during the operation to assess its structural integrity and to predict its behavior until the next in-service inspection. Hydrogen and deuterium concentration determination is one of the most important parameters to be evaluated during the experimental tests. Hydrogen present in zirconium alloys has a strong effect of weakening. Following the zirconium-hydrogen reaction, the resulting zirconium hydride precipitates in the mass of material. Weakening of the material, due to the presence of 10 ppm of precipitated hydrogen significantly affects some of its properties. The concentration of hydrogen in a sample can be determined by several methods, one of them being the differential scanning calorimetry (DSC). The principle of the method consists in measuring the difference between the amount of heat required to raise the temperature of a sample and a reference to a certain value. The experiments were made using a TA Instruments DSC Q2000 calorimeter. This paper contains experimental work for hydrogen concentration determination by Differential Scanning Calorimetry (DSC) method. Also, the reproducibility and accuracy of the method used at INR Pitesti are presented. (authors)

  13. Unusual Complication of Suprapubic Cystostomy in a Male Patient with Tetraplegia: Traction on Foley Catheter Leading to Extrusion of Foley Balloon from Urinary Bladder and Suprapubic Urinary Fistula – Importance of Securely Anchoring Suprapubic Catheter with Adhesive Tape or BioDerm Tube Holder

    Directory of Open Access Journals (Sweden)

    Subramanian Vaidyanathan

    2007-01-01

    Full Text Available Suprapubic cystostomy is recommended to patients with neuropathic bladder to prevent complications of long-term urethral catheter drainage. We present a 50-year-old male patient with tetraplegia who had long-term urethral catheter drainage. Following flexible cystoscopy, he developed a urine leak from the right side of the scrotum. Suprapubic cystostomy was performed. After suprapubic cystostomy, the urinary fistula healed completely. A follow-up cystourethrogram confirmed an intact urethra with no leak of contrast. Six weeks later, this patient presented with a hole below the suprapubic cystostomy through which a small amount of urine was leaking. A keyhole dressing had been applied around the suprapubic catheter and the catheter was hanging loosely, thus permitting traction on the catheter, especially when the urine bag was full. Computerised tomography of the pelvis showed extrusion of the Foley balloon from the urinary bladder, but the tip of the catheter was still located within the bladder. The extruded catheter was removed and a Foley catheter was inserted, ensuring that the balloon was inflated within the urinary bladder. The suprapubic catheter was secured firmly to the anterior abdominal wall with a BioDerm Tube Holder, thus preventing any traction on the catheter or Foley balloon. The urine leak through the hole below the suprapubic cystostomy stopped and the sinus healed. This case illustrates the need to anchor the suprapubic catheter securely to the anterior abdominal wall with adhesive tape or BioDerm Tube Holder to prevent traction and consequent displacement of the catheter or Foley balloon.

  14. Influence of endodontic instrument-holder on sterilization efficacy. A pilot in-vitro study.

    Directory of Open Access Journals (Sweden)

    Angelo Carrizo

    2013-08-01

    Full Text Available Infection control is crucial in dentistry and various methods have been designed to assure its efficacy. However, little information exists regarding the influence it could have the instrument-holder of endodontic files. The aim of this research was to determine the influence of three instruments-holders on sterilization efficacy of endodontic files. Methods: A pilot in-vitro study. 60 endodontic files were contaminated by biomechanical preparation of extracted molars with periapical abscess, then processed according to the standard washing method. The endodontic files were divided into 3 groups (n=20 and assigned to 3 instrument-holders: Metallic box (MB, surgical gauze (SG and synthetic sponge (SS. Then, the files were packaged and sterilized by autoclaving (134°C/45min. Microbiological culture was performed in thioglycolate solution for each endodontic file (37ºC/5days. Results: The overall sterilization efficacy was 91.7%, 80% for MB, 100% for SS, and 95% for SG, with no statistically significant differences (p=0.06 between the groups. Conclusions: The lack of differences in the efficacy of sterilization may be due to the reduced sample; therefore, a full-size study is necessary to confirm this outcomes. The results of this study discourage the use of the MB as instrument-holder until a full-size study can confirm this data.

  15. Knife - Holders in Ancient Egyptian Tombs (Religious and Artistic Study

    Directory of Open Access Journals (Sweden)

    dr.Rasha Omran

    2015-01-01

    Full Text Available Studying ancient Egyptian tombs have long been an important source of information regarding many aspects of Egyptian religion. Walls of New Kingdom tombs are often decorated with plenty of painted religious scenes. While they were primarily private structures containing images selected by the person who expected to be housed there for eternity, the funerary monuments also reflect religious beliefs. While numerous researches focused on many of the religious scenes depicted on the walls of ancient Egyptian tombs, no one focused on the knife - holders' scenes. Hence, the current study focused on knife - holders scenes depicted on the walls of both royal and private tombs dating back to the New Kingdom at Thebes. The current study was undertaken to shed light on the meaning and the function of knife in Ancient Egypt. To study the role of the knife-holders in Ancient Egypt. To spot light on the actions and behaviors and locations of the knife-holders in Ancient Egyptian civilization. To spot light on the representations of the knife-holders on the walls of the ancient Egyptians tombs in the Valley of the Kings and Valley of the Queens as well as the private tombs at western Thebes. To focus on the shapes and positions of the Knife-holders in Ancient Egypt. To explain the difference between Knife - Holders and Demons. To achieve the objectives of the study, the required data were collected from periodicals, references presenting Knife Holders scenes. Preserving the scenes of knife - holders on the walls of the royal tombs in the Valley of the Kings and Valley of the Queens dating back to the New Kingdom as well as the private tombs at western Thebes that contributed to the interpretation of all the data gathered from literature. The preliminary results indicated that the term (Knife-Holders is an expression which indicates to tomb-guardians, demons or minor divinities. These minor deities were subordinate to the major gods and goddesses. They

  16. Measurement of Passive Uptake Rates for Volatile Organic Compounds on Commercial Thermal Desorption Tubes and the Effect of Ozone on Sampling

    Energy Technology Data Exchange (ETDEWEB)

    Maddalena, Randy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Parra, Amanda [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Russell, Marion [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Lee, Wen-Yee [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-05-01

    Diffusive or passive sampling methods using commercially filled axial-sampling thermal desorption tubes are widely used for measuring volatile organic compounds (VOCs) in air. The passive sampling method provides a robust, cost effective way to measure air quality with time-averaged concentrations spanning up to a week or more. Sampling rates for VOCs can be calculated using tube geometry and Fick’s Law for ideal diffusion behavior or measured experimentally. There is evidence that uptake rates deviate from ideal and may not be constant over time. Therefore, experimentally measured sampling rates are preferred. In this project, a calibration chamber with a continuous stirred tank reactor design and constant VOC source was combined with active sampling to generate a controlled dynamic calibration environment for passive samplers. The chamber air was augmented with a continuous source of 45 VOCs ranging from pentane to diethyl phthalate representing a variety of chemical classes and physiochemical properties. Both passive and active samples were collected on commercially filled Tenax TA thermal desorption tubes over an 11-day period and used to calculate passive sampling rates. A second experiment was designed to determine the impact of ozone on passive sampling by using the calibration chamber to passively load five terpenes on a set of Tenax tubes and then exposing the tubes to different ozone environments with and without ozone scrubbers attached to the tube inlet. During the sampling rate experiment, the measured diffusive uptake was constant for up to seven days for most of the VOCs tested but deviated from linearity for some of the more volatile compounds between seven and eleven days. In the ozone experiment, both exposed and unexposed tubes showed a similar decline in terpene mass over time indicating back diffusion when uncapped tubes were transferred to a clean environment but there was no indication of significant loss by ozone reaction.

  17. Sample taking device for toxic and/or radioactive substances

    International Nuclear Information System (INIS)

    Finsterwalder, L.; Zeh, H.; Schaarschmidt, U.

    1979-01-01

    An apparatus for taking samples of toxic and/or radioactive liquid substances by introducing such substances into sample vessels includes a holder for holding such a vessel, at least one needle head filling system composed of upwardly pointing hollow needles for introducing a sample of one such substance into such a vessel at a filling position, and inlet and outlet conduits for pneumatically conveying vessels to or from the holder at a transfer position. The holder is composed of a turntable having a sleeve for accommodating such vessel and is mounted to undergo rotary movement to convey a sample vessel held in the sleeve between the filling and transfer positions. The apparatus further includes a stand supporting the filling system below the holder and a lifting device connected for imparting a translational movement to the holder to bring a vessel in the holder to operative association with the filling system. The lifting device is arranged so that the translational movement which it produces is independent of the rotary movement of the turntable

  18. Social Perception of Hydrogen Technologies: The View of Spanish Stake holders

    International Nuclear Information System (INIS)

    Ferri Anglada, S.

    2013-01-01

    This technical report presents an overview of the social perception and vision of a sample of Spanish stake holders on hydrogen technologies. The study is based on the implementation of a survey, combining both quantitative and qualitative data. An ad hoc electronic survey was design to collect views and perceptions on several key factors regarding this innovative energy alternative. The group of experts participating (N=130) in the study, comes mainly from research centers, universities and private companies. The survey addresses three major themes: expert views, social acceptability, and contextual factors of hydrogen technologies. The aim is to capture both the current and the future scene as viewed by the experts on hydrogen technologies, identifying key factors in terms of changes, uncertainties, obstacles and opportunities. The objective is to identify potential key features for the introduction, development, promotion, implementation, and large-scale deployment of a highly successful energy proposal in countries such as Iceland, one of the pioneers in base its economy on hydrogen technologies. To conclude, this report illustrates the positive engagement of a sample of Spanish stake holders towards hydrogen technologies that may prove vital in the transition towards the Hydrogen Economy in Spain. (Author)

  19. The Effect of Pneumatic Tube Systems on the Hemolysis of Biochemistry Blood Samples.

    Science.gov (United States)

    Cakirca, Gokhan; Erdal, Huseyin

    2017-05-01

    Pneumatic tube systems (PTSs) are widely used in many hospitals because they lead to reduced turnaround times and cost efficiency. However, PTSs may affect the quality of the blood samples transported to the laboratory. The aim of this study was to investigate the effect of the PTS used in our hospital on the hemolysis of the biochemical blood samples transported to the laboratory. A total of 148 samples were manually transported to the laboratory by hospital staff, 148 samples were transported with the PTS, and 113 were transported with the PTS without use of sponge-rubber inserts (PTSws). Hemolysis rates and the levels of biochemical analytes for the different transportation methods were compared. No significant difference was found between the samples transported manually and with the PTS with regard to hemolysis rate and the levels of biochemical analytes. However, the samples transported with the PTSws showed a significant difference compared with the samples transported manually and with the PTS with regard to hemolysis rate and potassium and lactate dehydrogenase levels. The percentages of the samples that exceeded the permissible threshold for the hemolysis among the samples transported manually, with the PTS, and with the PTSws were 10%, 8%, and 47%, respectively. A PTS can be used safely for transporting biochemistry blood samples to the laboratory. However, a sponge-rubber insert that holds sample tubes must be used with the PTS to prevent the hemolysis of blood samples. Copyright © 2016 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.

  20. Improvements in appliance holders

    International Nuclear Information System (INIS)

    Chapman, J.E.

    1977-01-01

    Reference is made to appliance holders for locating tools, instruments, etc. in operative relationship to workpieces and accessible through passageways of restricted transverse dimensions. The appliance holder described comprises an elongated external frame provided with transversely, outwardly expanding frictional gripping means in two longitudinally spaced sets and with a ring of spur teeth. An inner elongated frame is held within the external frame in two longitudinally spaced rotary bearings and carries a spur wheel which engages the ring of the spur teeth. A motor is arranged to rotate the spur wheel and hence the inner frame in relation to the external frame. A carriage is carried by the inner frame, longitudinally movable by a motor in relation thereto, and a further carriage is mounted on this first carriage. This second cariage is transversely movable in relation to the inner frame and is provided with a face plate for attachment of tools, instruments, etc. A motor is mounted on the first carriage for moving the second carriage. (U.K.)

  1. Blood Sampling in Newborns: A Systematic Review of YouTube Videos.

    Science.gov (United States)

    Bueno, Mariana; Nishi, Érika Tihemi; Costa, Taine; Freire, Laís Machado; Harrison, Denise

    Objective of this study was to conduct a systematic review of YouTube videos showing neonatal blood sampling, and to evaluate pain management and comforting interventions used. Selected videos were consumer- or professional-produced videos showing human newborns undergoing heel lancing or venipuncture for blood sampling, videos showing the entire blood sampling procedure (from the first attempt or puncture to the time of application of a cotton ball or bandage), publication date prior to October 2014, Portuguese titles, available audio. Search terms included "neonate," "newborn," "neonatal screening," and "blood collection." Two reviewers independently screened the videos and extracted the following data. A total of 13 140 videos were retrieved, of which 1354 were further evaluated, and 68 were included. Videos were mostly consumer produced (97%). Heel lancing was performed in 62 (91%). Forty-nine infants (72%) were held by an adult during the procedure. Median pain score immediately after puncture was 4 (interquartile range [IQR] = 0-5), and median length of cry throughout the procedure was 61 seconds (IQR = 88). Breastfeeding (3%) and swaddling (1.5%) were rarely implemented. Posted YouTube videos in Portuguese of newborns undergoing blood collection demonstrate minimal use of pain treatment, and maximal distress during procedures. Knowledge translation strategies are needed to implement effective measures for neonatal pain relief and comfort.

  2. A technique of taking samples from inside the pressure tube along the axis of the fuel channel

    International Nuclear Information System (INIS)

    Gyongyosi, T.

    2005-01-01

    Full text: The ageing process through its complex mechanisms affects in time more or less the component parts, the systems and the structures of the nuclear power plant. For CANDU type nuclear power plant the main component part in operation is the pressure tube, made from Zr - 2,5% Nb alloy, used in extreme hard operation conditions (static and dynamic loading from high pressure and temperature and high neutron flux). The pressure tube endures, in time, changing of the material and of the geometry. Additionally, the excessive hydrogen uptake initiates the Delayed Hydride Cracking (DHC) mechanism on the pressure tubes. For checking the evolution of the hydride / deuteration phenomena in the material of the pressure tube and especially to establish the real lifetime as compared to design lifetime it is useful to initiate, develop and apply a technology and a complex equipment for taking samples directly from inside the pressure tube, this enabling the determination of the hydrogen content. In the paper are showed briefly: - the evolution in time of the techniques for axial taking of the samples from inside of the pressure tube used in the CANDU 6 NPP; - the reasons that determined us to develop one of these technologies; - the technological facilities needed to apply it. (author)

  3. A technique of taking samples from inside the pressure tube along the axis of the fuel channel

    International Nuclear Information System (INIS)

    Gyongyosi, T.

    2005-01-01

    The ageing process through its complex mechanisms affects in time more or less the component parts, the systems and the structures of the nuclear power plant. For CANDU type nuclear power plant the main component part in operation is the pressure tube, made from Zr - 2,5% Nb alloy, used in extreme hard operation conditions (static and dynamic loading from high pressure and temperature and high neutron flux). The pressure tube endures, in time, changing of the material and of the geometry. Additionally, the excessive hydrogen uptake initiates the Delayed Hydride Cracking (DHC) mechanism on the pressure tubes. For checking the evolution of the hydride/deuteration phenomena in the material of the pressure tube and especially to establish the real lifetime as compared to design lifetime it is useful to initiate, develop and apply a technology and a complex equipment for taking samples directly from inside the pressure tube, this enabling the determination of the hydrogen content. In the paper are showed briefly: - the evolution in time of the techniques for axial taking of the samples from inside of the pressure tube used in the CANDU 6 NPP; - the reasons that determined us to develop one of these technologies; - the technological facilities needed to apply it. (author)

  4. 30 CFR 250.1010 - General requirements for pipeline right-of-way holders.

    Science.gov (United States)

    2010-07-01

    ... United States or its lessees or right-of-way holders, as the case may be, the full value of all damages...). The right-of-way holder shall make available all records relative to the design, construction... site. Furthermore, the holder is responsible for accidents or damages which might occur as a result of...

  5. Pumping time required to obtain tube well water samples with aquifer characteristic radon concentrations

    International Nuclear Information System (INIS)

    Ricardo, Carla Pereira; Oliveira, Arno Heeren de

    2011-01-01

    Radon is an inert noble gas, which comes from the natural radioactive decay of uranium and thorium in soil, rock and water. Radon isotopes emanated from radium-bearing grains of a rock or soil are released into the pore space. Radon that reaches the pore space is partitioned between the gaseous and aqueous phases. Thus, the groundwater presents a radon signature from the rock that is characteristic of the aquifer. The characteristic radon concentration of an aquifer, which is mainly related to the emanation, is also influenced by the degree of subsurface degassing, especially in the vicinity of a tube well, where the radon concentration is strongly reduced. Looking for the required pumping time to take a tube well water sample that presents the characteristic radon concentration of the aquifer, an experiment was conducted in an 80 m deep tube well. In this experiment, after twenty-four hours without extraction, water samples were collected periodically, about ten minutes intervals, during two hours of pumping time. The radon concentrations of the samples were determined by using the RAD7 Electronic Radon Detector from Durridge Company, a solid state alpha spectrometric detector. It was realized that the necessary time to reach the maximum radon concentration, that means the characteristic radon concentration of the aquifer, is about sixty minutes. (author)

  6. Studies and developments for the analysis of products of nuclear reprocessing plants with the help of the X-ray fluorescence analysis on totally reflecting sample holders (TXRF)

    International Nuclear Information System (INIS)

    Diercks, H.; Eggers, I.; Gibau, F.; Haarich, M.; Hastenteufel, S.; Haurand, M.; Knoechel, A.; Salow, H.

    1990-01-01

    Studies with inactive and active simulates of products of nuclear reprocessing plants show the suitability of the X-Ray Fluorescence Analysis on Totally Reflecting Sample Holders (TXRF), to detect the available elements simultaneously by direct measurements of specially prepared thin samples. High dilution enables in the most cases, to avoid working in hot cells and to carry out the analysis in glove boxes. The analysis of uranium products and great amounts of matrix elements containing solutions like LAW and MAW demands the separation of the matrix elements before TXRF measurement. Procedures for this task have been developed. The potential of the new analytical procedure was demonstrated by the analysis of two samples of highly diluted high active wastes. (orig.) With 65 refs., 20 tabs., 81 figs [de

  7. Irradiating cell samples in an x-ray radiation cabinet-the effect of tube filtration

    International Nuclear Information System (INIS)

    Parkin, Adrian; Wright, Ian; Yates, Stuart; Goldstone, Karen E; Russell, Paul; Starr, Christy

    2004-01-01

    The cell irradiation cabinet described is used for creating DNA damage in cell samples in order to study tumourigenesis. The medical research laboratory involved was using the manufacturer's quoted dose rate (32.2 mGy s -1 ) to determine the required exposure time to impart a dose of 10 Gy. The x-ray output was investigated when the exposure failed to produce cell cycle arrest. The x-ray tube was fitted with only a 0.76 mm beryllium filter, and the spectrum therefore contained a high proportion of low energy photons which were being removed by the polystyrene sample flask as demonstrated by dose measurements in air and through the sample flask. Incorporation of a 0.5 mm aluminium filter removed most of these low energy photons but greatly reduced the dose rate to 3.8 mGy s -1 . The manufacturer's quoted dose rates from a lightly filtered tube are misleading: the contribution of the very low energy component of the spectrum to the dose is not relevant since it will be removed by a sample flask. (note)

  8. Multilevel stake holder consensus building in radioactive waste management

    International Nuclear Information System (INIS)

    Dreimanis, Andrejs

    2008-01-01

    Full text: The increased demand of our society to its quality of life, global security and environmental safety as well as to observing a basic ethical principle of equity have advanced our attitude towards the recent proposals to develop shared multinational projects in the use of nuclear energy technologies, in particular, to: a) Siting of shared deep repositories for high-level radioactive waste (RW) and spent nuclear fuel safe disposal. In turn, arrangement of multinational facilities requires to gain more complex consensus between all involved parties. Method: We propose an interdisciplinary synergetic approach to multilevel consensus building for siting and construction of shared multinational repositories for RW deep disposal, based on self-organization (SO) of various stake holders, chaos and fuzziness concepts as well as Ashby principle of requisite variety. In the siting of a multi-national repository there appears an essential novel component of stake holder consensus building, namely: to reach consent - political, social, economic, ecological - among international partners, in addition to solving the whole set of intra-national consensus building items. An entire partnering country is considered as a national stake holder, represented by the national government, being faced to simultaneous seeking an upward (international) and a downward (intra-national) consensus in a psychologically stressed environment, having possibly diverse political, economic and social interests. Main Results: Following inferences about building of multilevel consensus are developed: 1) The basis of synergetic approach to stake holder interaction - informational SO, by forming a knowledge-creating stake holder community via cooperation and competition among individuals, public bodies/groups, companies, institutions; 2) Building of international stake holder consensus could be promoted by activating and diversifying multilateral interactions between intra- and international stake

  9. Freeze Protection in Gas Holders

    DEFF Research Database (Denmark)

    Hjorth, Poul G.; Duursma, Gail

    In cold weather, the water seals of gasholders need protection from freez- ing to avoid compromising the seal. These holders have a large reservoir of “tank water” at the base which is below ground. At present freeze- protection is achieved by external heating of the seal water which...

  10. A triple axes multiple target holder assembly

    International Nuclear Information System (INIS)

    Tribedi, L.C.; Narvekar, S.D.; Pillay, R.G.; Tandon, P.N.

    1993-01-01

    We have designed and fabricated a rotatable target holder assembly capable of accommodating 27 targets. The target foils are mounted along two concentric circles on a ss wheel. On the outer circle 18 targets can be mounted each 20deg apart, and on the inner circle the remaining targets are positioned each 40deg apart. The self supporting or carbon backed targets are mounted on thin frames and are placed concentrically at the targets are mounted on thin frames and are placed concentrically at the target position on the wheel. Three degrees of freedom are provided to the target holder assembly. (author). 1 fig

  11. Multistage open-tube trap for enrichment of part-per-trillion trace components of low-pressure (below 27-kPa) air samples

    Science.gov (United States)

    Ohara, D.; Vo, T.; Vedder, J. F.

    1985-01-01

    A multistage open-tube trap for cryogenic collection of trace components in low-pressure air samples is described. The open-tube design allows higher volumetric flow rates than densely packed glass-bead traps commonly reported and is suitable for air samples at pressures below 27 kPa with liquid nitrogen as the cryogen. Gas blends containing 200 to 2500 parts per trillion by volume each of ethane and ethene were sampled and hydrocarbons were enriched with 100 + or - 4 percent trap efficiency. The multistage design is more efficient than equal-length open-tube traps under the conditions of the measurements.

  12. Research on scholarships holders who studied abroad and returned to Serbia

    Directory of Open Access Journals (Sweden)

    Nena A. Vasojevic

    2017-10-01

    Full Text Available Knowledge has become the most valuable resource of the new era and the resource of the future. The intention of this study is to improve knowledge about the problem of migration of educated people from Serbia from the perspective of scholarship holders who, after being abroad, returned to their country. The aim of this research is to show the profile of the scholarship holders of post-academic and post-graduate students, who studied abroad and then returned to Serbia. Their motives for departure and return, as well as their perception of integration into the work environment in Serbia and utilization of their knowledge is presented. Methods: For the purpose of this research a questionnaire was constructed which was distributed online. Collected data were analysed using statistical tools. Results: This research has shown that the primary motive for education abroad is the desire for personal development. It has also been shown that an important factor for the return of students from abroad is their expectation of comparative advantage in the labour market and their belief of getting a desired job. Apart from this, it is shown that the scholarship holders only partially used the acquired knowledge and thus, do not have enough influence in the development of their organizations.Conclusion: The main research contribution is reflected in the improvement of the knowledge about the motivation of scholars to return from developed countries and highlighted problems which scholarship holders have after returning.Implications and research limitation: the results obtained can be generalised to countries that are passing or have recently moved a transition, and are similar in cultural characteristics. The present contains certain limitations that must be taken into account while interpreting final results. The most significant constraint is the sample size, but the obtained results, especially the motives of the scientific experts for a return to the country

  13. A simple cryo-holder facilitates specimen observation under a conventional scanning electron microscope.

    Science.gov (United States)

    Tang, Chih-Yuan; Huang, Rong-Nan; Kuo-Huang, Ling-Long; Kuo, Tai-Chih; Yang, Ya-Yun; Lin, Ching-Yeh; Jane, Wann-Neng; Chen, Shiang-Jiuun

    2012-02-01

    A pre-cryogenic holder (cryo-holder) facilitating cryo-specimen observation under a conventional scanning electron microscope (SEM) is described. This cryo-holder includes a specimen-holding unit (the stub) and a cryogenic energy-storing unit (a composite of three cylinders assembled with a screw). After cooling, the cryo-holder can continue supplying cryogenic energy to extend the observation time for the specimen in a conventional SEM. Moreover, the cryogenic energy-storing unit could retain appropriate liquid nitrogen that can evaporate to prevent frost deposition on the surface of the specimen. This device is proved feasible for various tissues and cells, and can be applied to the fields of both biology and material science. We have employed this novel cryo-holder for observation of yeast cells, trichome, and epidermal cells in the leaf of Arabidopsis thaliana, compound eyes of insects, red blood cells, filiform papillae on the surface of rat tongue, agar medium, water molecules, penicillium, etc. All results suggested that the newly designed cryo-holder is applicable for cryo-specimen observation under a conventional SEM without cooling system. Most importantly, the design of this cryo-holder is simple and easy to operate and could adapt a conventional SEM to a plain type cryo-SEM affordable for most laboratories. Copyright © 2011 Wiley Periodicals, Inc.

  14. Aquifer Sampling Tube Completion Report: 100 Area and Hanford Townsite Shorelines

    International Nuclear Information System (INIS)

    Peterson, R.E.; Borghese, J.V.; Erb, D.B.

    1998-02-01

    Groundwater contamination is known or suspected along the Hanford Site shoreline of the Columbia River adjacent to the retired reactor areas. Along the shoreline away from the reactor areas, where contamination is presumed to be absent, monitoring sites are frequently widely spaced or unavailable to confirm the presumption. Previous characterizations of contamination near the river have relied on data from a limited number of near-river wells, contaminant plume migration predictions, and river bank seepage sampling to anticipate shoreline conditions. In recent years, new methods have been developed to obtain groundwater samples from the aquifer near the groundwater/river water interface. These methods include using (1) divers to obtain samples of pore water from riverbed sediment and (2) sampling tubes that are driven into the aquifer at the shoreline. The latter method also permits sampling the aquifer at multiple depths, which helps to determine the thickness of the potentially contaminated groundwater layer that discharges into the river

  15. Failure analysis of vise jaw holders for hacksaw machine

    Directory of Open Access Journals (Sweden)

    Essam Ali Al-Bahkali

    2018-01-01

    Full Text Available Failure analysis in mechanical components has been investigated in many studies in the last few years. Failure analysis and prevention are important functions in all engineering disciplines. Materials engineers are often the lead role in the analysis of failures, where a component or product fails in service or if a failure occurs during manufacturing or production processing. In any case, one must determine the cause of the failure to prevent future occurrences and/or to improve the performance of the device, component or structure. For example, the vise jaw holders of hacksaws can break due to accidental heavy loads or machine misuse. The parts that break are the stationary and movable vise jaw holders and the connecter power screw between the holders. To investigate the failure of these components, a three-dimensional finite element model for stress analysis was performed. First, the analysis identified the broken components of the hacksaw machine. In addition, the type of materials of the broken parts was identified, a CAD model was built, and the hacksaw mechanism was analyzed to determine the accurate applied loads on the broken parts. After analyzing the model using Abaqus CAE software, the results showed that the location of the high stresses was identical with the high-stress locations in the original, broken parts. Furthermore, the power screw was subjected to a high load, which deformed the power screw. Also, the stationary vise jaw holder was broken by impact because it was not touched by the power screw until the movable vise jaw holder broke. A conclusion is drawn from the failure analysis and a way to improve the design of the broken parts is suggested.

  16. Research on the tool holder mode in high speed machining

    Science.gov (United States)

    Zhenyu, Zhao; Yongquan, Zhou; Houming, Zhou; Xiaomei, Xu; Haibin, Xiao

    2018-03-01

    High speed machining technology can improve the processing efficiency and precision, but also reduce the processing cost. Therefore, the technology is widely regarded in the industry. With the extensive application of high-speed machining technology, high-speed tool system has higher and higher requirements on the tool chuck. At present, in high speed precision machining, several new kinds of clip heads are as long as there are heat shrinkage tool-holder, high-precision spring chuck, hydraulic tool-holder, and the three-rib deformation chuck. Among them, the heat shrinkage tool-holder has the advantages of high precision, high clamping force, high bending rigidity and dynamic balance, etc., which are widely used. Therefore, it is of great significance to research the new requirements of the machining tool system. In order to adapt to the requirement of high speed machining precision machining technology, this paper expounds the common tool holder technology of high precision machining, and proposes how to select correctly tool clamping system in practice. The characteristics and existing problems are analyzed in the tool clamping system.

  17. A cryogenic tensile testing apparatus for micro-samples cooled by miniature pulse tube cryocooler

    International Nuclear Information System (INIS)

    Chen, L B; Liu, S X; Gu, K X; Zhou, Y; Wang, J J

    2015-01-01

    This paper introduces a cryogenic tensile testing apparatus for micro-samples cooled by a miniature pulse tube cryocooler. At present, tensile tests are widely applied to measure the mechanical properties of materials; most of the cryogenic tensile testing apparatus are designed for samples with standard sizes, while for non-standard size samples, especially for microsamples, the tensile testing cannot be conducted. The general approach to cool down the specimens for tensile testing is by using of liquid nitrogen or liquid helium, which is not convenient: it is difficult to keep the temperature of the specimens at an arbitrary set point precisely, besides, in some occasions, liquid nitrogen, especially liquid helium, is not easily available. To overcome these limitations, a cryogenic tensile testing apparatus cooled by a high frequency pulse tube cryocooler has been designed, built and tested. The operating temperatures of the developed tensile testing apparatus cover from 20 K to room temperature with a controlling precision of ±10 mK. The apparatus configurations, the methods of operation and some cooling performance will be described in this paper. (paper)

  18. Custom sample environments at the ALBA XPEEM

    Energy Technology Data Exchange (ETDEWEB)

    Foerster, Michael, E-mail: mfoerster@cells.es; Prat, Jordi; Massana, Valenti; Gonzalez, Nahikari; Fontsere, Abel; Molas, Bernat; Matilla, Oscar; Pellegrin, Eric; Aballe, Lucia

    2016-12-15

    A variety of custom-built sample holders offer users a wide range of non-standard measurements at the ALBA synchrotron PhotoEmission Electron Microscope (PEEM) experimental station. Some of the salient features are: an ultrahigh vacuum (UHV) suitcase compatible with many offline deposition and characterization systems, built-in electromagnets for uni- or biaxial in-plane (IP) and out-of-plane (OOP) fields, as well as the combination of magnetic fields with electric fields or current injection. Electronics providing a synchronized sinusoidal signal for sample excitation enable time-resolved measurements at the 500 MHz storage ring RF frequency. - Highlights: • Custom sample environment for XPEEM at ALBA. • Sample holders with electromagnets, in-plane dipole, in-plane quadruple and out-of-plane. • Sample holders with printed circuit boards for electric contacts including electromagnets. • UHV suitcase adapter. • Synchronized 500 MHz electrical excitation for time resolved measurements.

  19. Comparison of digoxin concentration in plastic serum tubes with clot activator and heparinized plasma tubes.

    Science.gov (United States)

    Dukić, Lora; Simundić, Ana-Maria; Malogorski, Davorin

    2014-01-01

    Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = -0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration.

  20. Biocompatible in-tube solid phase microextraction coupled with liquid chromatography-fluorescence detection for determination of interferon α in plasma samples.

    Science.gov (United States)

    Chaves, Andréa R; Silva, Bruno J G; Lanças, Fernando M; Queiroz, Maria Eugênia C

    2011-05-27

    The present work demonstrates the successful application of automated biocompatible in-tube solid-phase microextraction coupled with liquid chromatography (in-tube SPME/LC) for determination of interferon alpha(2a) (IFN α(2a)) in plasma samples for therapeutic drug monitoring. A restricted access material (RAM, protein-coated silica) was employed for preparation of a lab-made biocompatible in-tube SPME capillary that enables the direct injection of biological fluids as well as the simultaneous exclusion of macromolecules by chemical diffusion barrier and drug pre-concentration. The in-tube SPME variables, such as sample volume, draw/eject volume, number of draw-eject cycles, and desorption mode were optimized, to improve the sensitivity of the proposed method. The IFN α(2a) analyses in plasma sample were carried out within 25min (sample preparation and LC analyses). The response of the proposed method was linear over a dynamic range, from 0.06 to 3.0MIUmL(-1), with correlation coefficient equal to 0.998. The interday precision of the method presented coefficient of variation lower than 8%. The proposed automated method has adequate analytical sensitivity and selectivity for determination of IFN α(2a) in plasma samples for therapeutic drug monitoring. Copyright © 2010 Elsevier B.V. All rights reserved.

  1. Choosing health: qualitative evidence from the experiences of personal health budget holders.

    Science.gov (United States)

    Davidson, Jacqueline; Baxter, Kate; Glendinning, Caroline; Irvine, Annie

    2013-10-01

    Personal health budgets were piloted in the English National Health Service between 2009 and 2012. Semi-structured interviews with a sub-sample of early budget holders aimed to explore their experiences of receiving and using a budget. Over 2000 people from 20 pilot sites were recruited to a multi-method evaluation of the personal health budget pilots. A sub-sample of 58 people was selected for qualitative interviews three months after the offer of a budget; 52 were re-interviewed six months later. The purposively selected sample reflected a range of health conditions, locality, age and gender. Personal health budgets were reported to have positive impacts on health, health care and relatives/family. Benefits often extended beyond the condition for which the budget had been awarded. However, interviewees rarely knew the level of their budget; some reported difficulty in agreeing acceptable uses for their budget; and delays could occur in procuring chosen services or equipment. Patients' experiences offer valuable insights for the roll-out of personal health budgets beyond the pilot phase. Flexibility in how budgets are used may allow maximum benefits to be derived. Clear information about what budgets can and cannot be used for, with suggestions offered, will be useful. People with newly diagnosed or recent sudden onset conditions may need more help to plan their support, but all budget holders are likely to benefit from regular contact with staff for reassurance and continued motivation.

  2. Lathe tool bit and holder for machining fiberglass materials

    Science.gov (United States)

    Winn, L. E. (Inventor)

    1972-01-01

    A lathe tool and holder combination for machining resin impregnated fiberglass cloth laminates is described. The tool holder and tool bit combination is designed to accommodate a conventional carbide-tipped, round shank router bit as the cutting medium, and provides an infinite number of cutting angles in order to produce a true and smooth surface in the fiberglass material workpiece with every pass of the tool bit. The technique utilizes damaged router bits which ordinarily would be discarded.

  3. 7 CFR 1463.105 - Base quota levels for eligible quota holders.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Base quota levels for eligible quota holders. 1463.105 Section 1463.105 Agriculture Regulations of the Department of Agriculture (Continued) COMMODITY... TRANSITION PROGRAM Tobacco Transition Payment Program § 1463.105 Base quota levels for eligible quota holders...

  4. Effects of Storage and Type of Blood Collection Tubes on Hepatitis C Virus Level in Whole Blood Samples

    Science.gov (United States)

    Kessler, Harald H.; Stelzl, Evelyn; Raggam, Reinhard B.; Haas, Josef; Kirchmeir, Franz; Hegenbarth, Karin; Daghofer, Elisabeth; Santner, Brigitte I.; Marth, Egon; Stauber, Rudolf E.

    2001-01-01

    In this study, we compared serum hepatitis C virus (HCV) RNA concentrations with HCV RNA concentrations in whole blood collection tubes, including two different types of EDTA tubes and nucleic acid stabilization tubes (NASTs). We also investigated the impact of a processing delay on HCV RNA concentration in these tubes. In NASTs, the mean HCV RNA concentration was comparable to the mean serum HCV RNA concentration at “date zero.” In EDTA tubes, mean baseline HCV RNA concentrations were higher. Storage at room temperature up to 96 h did not result in a decline of HCV RNA concentration in any of the whole blood collection tubes. In NASTs, HCV RNA concentrations remained stable during the whole study period, whereas a significant increase of HCV RNA was observed in both types of EDTA tubes at 96 h compared to date zero. We concluded that HCV RNA remains stable in NASTs at room temperature for at least 96 h, allowing greater flexibility in sample collection and transport. PMID:11325991

  5. 21 CFR 892.1920 - Radiographic head holder.

    Science.gov (United States)

    2010-04-01

    ...) Identification. A radiographic head holder is a device intended to position the patient's head during a... device is also exempt from the current good manufacturing practice requirements of the quality system...

  6. Equipment for linking source stand and film holder carriage

    International Nuclear Information System (INIS)

    Fajt, P.; Zeman, M.

    1987-01-01

    A device is described for precision link-up of a source stand provided with a spring-loaded cam and a film holder carriage provided with an arm with catches. The catches are mechanically connected to a control device firmly connected to the bottom part of the film holder carriage arm. The cam whose extended part is slidably mounted in the cover guide is secured in position with springs fitted from both sides. The control device consists of an electromagnet with armature connected to the control device pull-rod. The pull-rod provides mechanical connection of the catches and the control device. Upon pressing the pushbutton, the catches automatically engage the film holder cariage arm so that the motorized source stand operates without connection to the carriage. This significantly facilitates the operation of the equipment and reduces physical effort of the technician. The most significant advantage is the possibility of immediate change in operation mode. (J.B.). 5 figs

  7. Brittle Fracture Behaviors of Large Die Holders Used in Hot Die Forging

    Directory of Open Access Journals (Sweden)

    Weifang Zhang

    2017-05-01

    Full Text Available Brittle fracture of large forging equipment usually leads to catastrophic consequences. To avoid this kind of accident, the brittle fracture behaviors of a large die holder were studied by simulating the practical application. The die holder is used on the large die forging press, and it is made of 55NiCrMoV7 hot-work tool steel. Detailed investigations including mechanical properties analysis, metallographic observation, fractography, transmission electron microscope (TEM analysis and selected area electron diffraction (SAED were conducted. The results reveal that the material generated a large quantity of large size polyhedral M23C6 (M: Fe and Cr mainly and elongated M3C (M: Fe mainly carbides along the martensitic lath boundaries when the die holder was recurrently tempered and water-cooled at 250 °C during the service. The large size carbides lead to the material embrittlement and impact toughness degradation, and further resulted in the brittle fracture of the die holder. Therefore, the operation specification must be emphasized to avoid the die holder being cooled by using water, which is aimed at accelerating the cooling.

  8. Implementation of a Light Source in a TEM Sample Holder for In-situ Studies of Photocatalytic Materials

    DEFF Research Database (Denmark)

    Cavalca, Filippo; Hansen, Thomas Willum; Wagner, Jakob Birkedal

    can be used inside an environmental TEM (ETEM) allowing specimens to be analyzed during exposure to a controlled gas atmosphere and illumination. The holder is presently being used to study a variety of photoreactive materials and structures, including photocatalysts, photonic devices and solar cells....... For example, electron holography is being used to study p-n junctions both in the presence and in the absence of light in order to assess electron beam induced charging and discharging effects during laser light exposure [3]. Here, we present results from ETEM studies of light-induced phenomena that include...

  9. 14 CFR 26.33 - Holders of type certificates: Fuel tank flammability.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Holders of type certificates: Fuel tank... Tank Flammability § 26.33 Holders of type certificates: Fuel tank flammability. (a) Applicability. This... part 25 of this chapter. (2) Exception. This paragraph (b) does not apply to— (i) Fuel tanks for which...

  10. Heat Exchanger Tube to Tube Sheet Joints Corrosion Behavior

    Directory of Open Access Journals (Sweden)

    M. Iancu

    2013-03-01

    Full Text Available Paper presents the studies made by the authors above the tube to tube sheet fittings of heat exchanger with fixed covers from hydrofining oil reforming unit. Tube fittings are critical zones for heat exchangers failures. On a device made from material tube and tube sheet at real joints dimensions were establish axial compression force and traction force at which tube is extracted from expanded joint. Were used two shapes joints with two types of fittings surfaces, one with smooth hole of tube sheet and other in which on boring surface we made a groove. From extracted expanded tube zones were made samples for corrosion tests in order to establish the corrosion rate, corrosion potential and corrosion current in working mediums such as hydrofining oil and industrial water at different temperatures. The corrosion rate values and the temperature influence are important to evaluate joints durability and also the results obtained shows that the boring tube sheet shape with a groove on hole tube shape presents a better corrosion behavior then the shape with smooth hole tube sheet.

  11. 77 FR 69650 - Agency Information Collection Activities: Holders or Containers Which Enter the United States...

    Science.gov (United States)

    2012-11-20

    ... Activities: Holders or Containers Which Enter the United States Duty Free AGENCY: U.S. Customs and Border... information collection requirement concerning the Holders or Containers which Enter the United States Duty... concerning the following information collection: Title: Holders or Containers which Enter the United States...

  12. Selective molecularly imprinted polymer combined with restricted access material for in-tube SPME/UHPLC-MS/MS of parabens in breast milk samples

    International Nuclear Information System (INIS)

    Souza, Israel D.; Melo, Lidervan P.; Jardim, Isabel C.S.F.; Monteiro, Juliana C.S.; Nakano, Ana Marcia S.; Queiroz, Maria Eugênia C.

    2016-01-01

    A new molecularly imprinted polymer modified with restricted access material (a hydrophilic external layer), (MIP-RAM) was synthesized via polymerization in situ in an open fused silica capillary. This stationary phase was used as sorbent for in-tube solid phase microextraction (in-tube SPME) to determine parabens in breast milk samples by ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Scanning electron micrographs (SEM) illustrate MIP surface modification after glycerol dimethacrylate (hydrophilic monomer) incorporation. The interaction between parabens and MIP-RAM was investigated by Fourier-transform infrared (FTIR) spectroscopy. The Scatchard plot for MIP-RAM presented two linear parts with different slopes, illustrating binding sites with high- and low-affinity. Endogenous compounds exclusion from the MIP-RAM capillary was demonstrated by in-tube SPME/LC-UV assays carried out with blank milk samples. The in-tube SPME/UHPLC-MS/MS method presented linear range from 10 ng mL"−"1 (LLOQ) to 400 ng mL"−"1 with coefficients of determination higher than 0.99, inter-assay precision with coefficient of variation (CV) values ranging from 2 to 15%, and inter-assay accuracy with relative standard deviation (RSD) values ranging from −1% to 19%. Analytical validation parameters attested that in-tube SPME/UHPLC-MS/MS is an appropriate method to determine parabens in human milk samples to assess human exposure to these compounds. Analysis of breast milk samples from lactating women demonstrated that the proposed method is effective. - Highlights: • Molecularly imprinted polymer modified with a hydrophilic external layer (RAM-MIP) was synthesized in a silica capillary. • RAM-MIP capillary, used as sorbent for in-tube SPME, established specific interaction with parabens present in milk samples. • The matrix components that interacted only with the hydrophilic external layer (non-adsorptive network) were excluded. • The

  13. Selective molecularly imprinted polymer combined with restricted access material for in-tube SPME/UHPLC-MS/MS of parabens in breast milk samples

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Israel D.; Melo, Lidervan P. [Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Jardim, Isabel C.S.F. [Instituto de Química, Universidade Estadual de Campinas, Campinas, SP (Brazil); Monteiro, Juliana C.S.; Nakano, Ana Marcia S. [Escola de Enfermagem de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Queiroz, Maria Eugênia C., E-mail: mariaeqn@ffclrp.usp.br [Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil)

    2016-08-17

    A new molecularly imprinted polymer modified with restricted access material (a hydrophilic external layer), (MIP-RAM) was synthesized via polymerization in situ in an open fused silica capillary. This stationary phase was used as sorbent for in-tube solid phase microextraction (in-tube SPME) to determine parabens in breast milk samples by ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Scanning electron micrographs (SEM) illustrate MIP surface modification after glycerol dimethacrylate (hydrophilic monomer) incorporation. The interaction between parabens and MIP-RAM was investigated by Fourier-transform infrared (FTIR) spectroscopy. The Scatchard plot for MIP-RAM presented two linear parts with different slopes, illustrating binding sites with high- and low-affinity. Endogenous compounds exclusion from the MIP-RAM capillary was demonstrated by in-tube SPME/LC-UV assays carried out with blank milk samples. The in-tube SPME/UHPLC-MS/MS method presented linear range from 10 ng mL{sup −1} (LLOQ) to 400 ng mL{sup −1} with coefficients of determination higher than 0.99, inter-assay precision with coefficient of variation (CV) values ranging from 2 to 15%, and inter-assay accuracy with relative standard deviation (RSD) values ranging from −1% to 19%. Analytical validation parameters attested that in-tube SPME/UHPLC-MS/MS is an appropriate method to determine parabens in human milk samples to assess human exposure to these compounds. Analysis of breast milk samples from lactating women demonstrated that the proposed method is effective. - Highlights: • Molecularly imprinted polymer modified with a hydrophilic external layer (RAM-MIP) was synthesized in a silica capillary. • RAM-MIP capillary, used as sorbent for in-tube SPME, established specific interaction with parabens present in milk samples. • The matrix components that interacted only with the hydrophilic external layer (non-adsorptive network) were excluded.

  14. Development of a magnetic measurement device for thin ribbon samples

    International Nuclear Information System (INIS)

    Sato, Yuta; Todaka, Takashi; Enokizono, Masato

    2008-01-01

    This paper presents a magnetic measurement device for thin ribbon samples, which are produced by rapid cooling technique. This device enables us to measure magnetic properties easily by only inserting a ribbon sample into a sample holder. The sample holder was made by bakelite to fix any width sample. A long solenoid coil was used to generate a uniform magnetic field and the sample holder was placed at the mid part of the solenoid. The magnetic field strength was measured using a shunt resistor and the magnetic flux density and magnetization in sample ribbons were evaluated by using search coils. The accuracy of measurement was verified with an amorphous metal ribbon sample. Next, we have measured magnetic properties of some magnetic shape memory alloys, which have different compositions. The measured results are compared and we clarified the effect of Sm contents on the magnetic properties

  15. Failure analysis of boiler tube

    International Nuclear Information System (INIS)

    Mehmood, K.; Siddiqui, A.R.

    2007-01-01

    Boiler tubes are energy conversion components where heat energy is used to convert water into high pressure superheated steam, which is then delivered to a turbine for electric power generation in thermal power plants or to run plant and machineries in a process or manufacturing industry. It was reported that one of the tubes of a fire-tube boiler used in a local industry had leakage after the formation of pits at the external surface of the tube. The inner side of the fire tube was working with hot flue gasses with a pressure of 10 Kg/cm/sup 2/ and temperature 225 degree C. The outside of the tube was surrounded by feed water. The purpose of this study was to determine the cause of pits developed at the external surface of the failed boiler tube sample. In the present work boiler tube samples of steel grade ASTM AI61/ASTM A192 were analyzed using metallographic analysis, chemical analysis, and mechanical testing. It was concluded that the appearance of defects on the boiler tube sample indicates cavitation type corrosion failure. Cavitation damage superficially resembled pitting, but surface appeared considerably rougher and had many closely spaced pits. (author)

  16. Neutron flux measurements in C-9 capsule pressure tube

    International Nuclear Information System (INIS)

    Barbos, D.; Roth, C. S.; Gugiu, D.; Preda, M.

    2001-01-01

    C-9 capsule is a fuel testing facility in which the testing consists of a daily cycle ranging between the limits 100% power to 50% power. C-9 in-pile section with sample holder an instrumentation are introduced in G-9 and G-10 experimental channels. The experimental fuel channel has a maximum value when the in-pile section (pressure tube) is in G-9 channel and minimum value in G-10 channel. In this paper the main goals are determination or measurements of: - axial thermal neutron flux distribution in C-9 pressure tube both in G-9 and G-10 channel; - ratio of maximum neutron flux value in G-9 and the same value in G-9 channel and the same value in G-10 channel; - neutron flux-spectrum. On the basis of axial neutron flux distribution measurements, the experimental fuel element in sample holder position in set. Both axial neutron flux distribution of thermal neutrons and neutron flux-spectrum were performed using multi- foil activation technique. Activation rates were obtained by absolute measurements of the induced activity using gamma spectroscopy methods. To determine the axial thermal neutron flux distribution in G-9 and G-10, Cu 100% wire was irradiated at the reactor power of 2 MW. Ratio between the two maximum values, in G-9 and G-10 channels, is 2.55. Multi-foil activation method was used for neutron flux spectrum measurements. The neutron spectra and flux were obtained from reaction rate measurements by means of SAND 2 code. To obtain gamma-ray spectra, a HPGe detector connected to a multichannel analyzer was used. The spectrometer is absolute efficiency calibrated. The foils were irradiated at 2 MW reactor power in previously determined maximum flux position resulted from wire measurements. This reaction rates were normalized for 10 MW reactor power. Neutron self shielding corrections for the activation foils were applied. The self-shielding corrections are computed using Monte Carlo simulation methods. The measured integral flux is 1.1·10 14 n/cm 2 s

  17. Fatigue crack initiation at complex flaws in hydrided Zr-2.5%Nb samples from CANDU pressure tubes

    International Nuclear Information System (INIS)

    Stoica, L.; Radu, V.

    2016-01-01

    The paper addresses the phenomena which occur at locations where the oxide layer of the inner surface of CANDU tube pressure is damaged by the contact with the fuel element or due to the action of hard particles at the interface between the tube pressure and bearing pad of fuel element. In such situations generate defects, which most often are defects known as ''bearing pad fretting flaws'' or ''debris fretting flaws''. In this paper the experiments are completed in a series of previous works on the mechanical fatigue phenomenon on samples prepared from the pressure tube Zr-2.5% Nb alloy. The phenomenon of variable mechanical stress (or fatigue) may lead to initiation of cracks at the tip of volumetric flaws, according to the accumulation of hydrides, which then fractures and can propagate through the tube wall pressure due to the mechanism of type DHC (Delayed Hydride Cracking). (authors)

  18. [Complaints by private health insurance policy-holders to the Consumer Protection Bureau in Argentina, 2000-2008].

    Science.gov (United States)

    Luzuriaga, María José; Spinelli, Hugo

    2014-05-01

    This paper analyzes problems experienced by policy-holders of voluntary private health insurance plans in Argentina when insurance companies fail to comply with the Consumer Protection Code. The sample consisted of consumer complaints filed with the Consumer Protection Bureau and rulings by the Bureau from 2000 to 2008. One striking issue was recurrent non-compliance with services included in the Mandatory Medical Program and the companies' attempts to blame policy-holders. According to the study, the lack of an information system hinders scientific studies to adequately address the problem. Thus, a comparison with studies on health insurance in other Latin American countries highlighted the importance of such research, the relationship to health systems, constraints on use and denial of citizens' rights to healthcare, and the increasing judicialization of healthcare provision.

  19. Effect of tubing length on the dispersion correction of an arterially sampled input function for kinetic modeling in PET.

    Science.gov (United States)

    O'Doherty, Jim; Chilcott, Anna; Dunn, Joel

    2015-11-01

    Arterial sampling with dispersion correction is routinely performed for kinetic analysis of PET studies. Because of the the advent of PET-MRI systems, non-MR safe instrumentation will be required to be kept outside the scan room, which requires the length of the tubing between the patient and detector to increase, thus worsening the effects of dispersion. We examined the effects of dispersion in idealized radioactive blood studies using various lengths of tubing (1.5, 3, and 4.5 m) and applied a well-known transmission-dispersion model to attempt to correct the resulting traces. A simulation study was also carried out to examine noise characteristics of the model. The model was applied to patient traces using a 1.5 m acquisition tubing and extended to its use at 3 m. Satisfactory dispersion correction of the blood traces was achieved in the 1.5 m line. Predictions on the basis of experimental measurements, numerical simulations and noise analysis of resulting traces show that corrections of blood data can also be achieved using the 3 m tubing. The effects of dispersion could not be corrected for the 4.5 m line by the selected transmission-dispersion model. On the basis of our setup, correction of dispersion in arterial sampling tubing up to 3 m by the transmission-dispersion model can be performed. The model could not dispersion correct data acquired using a 4.5 m arterial tubing.

  20. FlexED8: the first member of a fast and flexible sample-changer family for macromolecular crystallography.

    Science.gov (United States)

    Papp, Gergely; Felisaz, Franck; Sorez, Clement; Lopez-Marrero, Marcos; Janocha, Robert; Manjasetty, Babu; Gobbo, Alexandre; Belrhali, Hassan; Bowler, Matthew W; Cipriani, Florent

    2017-10-01

    Automated sample changers are now standard equipment for modern macromolecular crystallography synchrotron beamlines. Nevertheless, most are only compatible with a single type of sample holder and puck. Recent work aimed at reducing sample-handling efforts and crystal-alignment times at beamlines has resulted in a new generation of compact and precise sample holders for cryocrystallography: miniSPINE and NewPin [see the companion paper by Papp et al. (2017, Acta Cryst., D73, 829-840)]. With full data collection now possible within seconds at most advanced beamlines, and future fourth-generation synchrotron sources promising to extract data in a few tens of milliseconds, the time taken to mount and centre a sample is rate-limiting. In this context, a versatile and fast sample changer, FlexED8, has been developed that is compatible with the highly successful SPINE sample holder and with the miniSPINE and NewPin sample holders. Based on a six-axis industrial robot, FlexED8 is equipped with a tool changer and includes a novel open sample-storage dewar with a built-in ice-filtering system. With seven versatile puck slots, it can hold up to 112 SPINE sample holders in uni-pucks, or 252 miniSPINE or NewPin sample holders, with 36 samples per puck. Additionally, a double gripper, compatible with the SPINE sample holders and uni-pucks, allows a reduction in the sample-exchange time from 40 s, the typical time with a standard single gripper, to less than 5 s. Computer vision-based sample-transfer monitoring, sophisticated error handling and automatic error-recovery procedures ensure high reliability. The FlexED8 sample changer has been successfully tested under real conditions on a beamline.

  1. Manipulation and functionalization of nano-tubes: application to boron nitride nano-tubes

    International Nuclear Information System (INIS)

    Maguer, A.

    2007-01-01

    This PhD work is divided into two parts dealing with boron nitride (BNNT) and carbon nano-tubes. The first part is about synthesis, purification and chemical functionalization of BNNT. Single-walled BNNT are synthesized by LASER ablation of a hBN target. Improving the synthesis parameters first allowed us to limit the byproducts (hBN, boric acid). A specific purification process was then developed in order to enrich the samples in nano-tubes. Purified samples were then used to develop two new chemical functionalization methods. They both involve chemical molecules that present a high affinity towards the BN network. The use of long chain-substituted quinuclidines and borazines actually allowed the solubilization of BNNT in organic media. Purification and functionalization were developed for single-walled BNNT and were successfully applied to multi-walled BNNT. Sensibility of boron to thermic neutrons finally gave birth to a study about covalent functionalization possibilities of the network. The second part of the PhD work deals with separation of carbon nano-tubes depending on their properties. Microwave irradiation of carbon nano-tubes first allowed the enrichment of initially polydisperse samples in large diameter nano-tubes. A second strategy involving selective interaction between one type of tubes and fullerene micelles was finally envisaged to selectively solubilize carbon nano-tubes with specific electronic properties. (author) [fr

  2. A large deviation principle in H\\"older norm for multiple fractional integrals

    OpenAIRE

    Sanz-Solé, Marta; Torrecilla-Tarantino, Iván

    2007-01-01

    For a fractional Brownian motion $B^H$ with Hurst parameter $H\\in]{1/4},{1/2}[\\cup]{1/2},1[$, multiple indefinite integrals on a simplex are constructed and the regularity of their sample paths are studied. Then, it is proved that the family of probability laws of the processes obtained by replacing $B^H$ by $\\epsilon^{{1/2}} B^H$ satisfies a large deviation principle in H\\"older norm. The definition of the multiple integrals relies upon a representation of the fractional Brownian motion in t...

  3. 26 CFR 1.860C-1 - Taxation of holders of residual interests.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Taxation of holders of residual interests. 1.860C-1 Section 1.860C-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Real Estate Investment Trusts § 1.860C-1 Taxation of holders...

  4. Comparison of blood RNA isolation methods from samples stabilized in Tempus tubes and stored at a large human biobank.

    Science.gov (United States)

    Aarem, Jeanette; Brunborg, Gunnar; Aas, Kaja K; Harbak, Kari; Taipale, Miia M; Magnus, Per; Knudsen, Gun Peggy; Duale, Nur

    2016-09-01

    More than 50,000 adult and cord blood samples were collected in Tempus tubes and stored at the Norwegian Institute of Public Health Biobank for future use. In this study, we systematically evaluated and compared five blood-RNA isolation protocols: three blood-RNA isolation protocols optimized for simultaneous isolation of all blood-RNA species (MagMAX RNA Isolation Kit, both manual and semi-automated protocols; and Norgen Preserved Blood RNA kit I); and two protocols optimized for large RNAs only (Tempus Spin RNA, and Tempus 6-port isolation kit). We estimated the following parameters: RNA quality, RNA yield, processing time, cost per sample, and RNA transcript stability of six selected mRNAs and 13 miRNAs using real-time qPCR. Whole blood samples from adults (n = 59 tubes) and umbilical cord blood (n = 18 tubes) samples collected in Tempus tubes were analyzed. High-quality blood-RNAs with average RIN-values above seven were extracted using all five RNA isolation protocols. The transcript levels of the six selected genes showed minimal variation between the five protocols. Unexplained differences within the transcript levels of the 13 miRNA were observed; however, the 13 miRNAs had similar expression direction and they were within the same order of magnitude. Some differences in the RNA processing time and cost were noted. Sufficient amounts of high-quality RNA were obtained using all five protocols, and the Tempus blood RNA system therefore seems not to be dependent on one specific RNA isolation method.

  5. 16 CFR Figure 3 to Part 1610 - Specimen Holder Supported in Specimen Rack

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Specimen Holder Supported in Specimen Rack 3 Figure 3 to Part 1610 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT... Holder Supported in Specimen Rack ER25MR08.002 ...

  6. Construction and application of a double scanning sample holder; Construction et application d'un porte-echantillon a double balladage

    Energy Technology Data Exchange (ETDEWEB)

    Petit, J; Cabane, G [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1954-07-01

    Crystal growth often interferes in the analysis of orientation textures of annealed sheets; in order to achieve the hitting of a great number of grains by the X-ray beam, the sample must be moved in its own plane, the rolling direction remaining parallel to itself. For the study of rolled uranium annealing, one linear scanning was found insufficient; therefore the authors developed a double scanning sample holder allowing the survey of a surface up to 6 or 8 cm{sup 2}. Thus, for recrystallized samples with a grain diameter up to 1 mm, continuous diffraction lines can be obtained. The first diagrams confirm the dilatometric results relating to the texture changes due to {alpha} annealing hard-rolled sheets or to the {alpha}-{beta} allotropic transformation. (author) [French] L'analyse des textures d'orientation des toles apres recuit est souvent genee par le grossissement des cristaux; pour que le faisceau de rayons X frappe toujours un grand nombre de cristaux, on est alors conduit a deplacer l'echantillon dans son plan, la direction de laminage restant parallele a elle eme. Dans l'etude du recuit de l'uranium lamine, un balladage lineaire est insuffisant; c'est pourquoi on a realise un porte chantillon a double balladage permettant l'exploration d'une surface de 6 a 8 cm{sup 2}; on obtient ainsi des anneaux de diffraction continus avec des echantillons recristallises a grains de diametre inferieur ou egal a 1 mm. Les premiers cliches effectues avec cet appareil ont confirme les resultats dilatometriques concernant le changement de texture par recuit en phase {alpha} des toles laminees a fort taux d'ecrouissage, ainsi que le changement de texture au passage de la transformation allotropique {alpha}-{beta}. (auteur)

  7. 19 CFR 134.22 - General rules for marking of containers or holders.

    Science.gov (United States)

    2010-04-01

    ... required for any good of a NAFTA country which is a usual container. (c) Containers or holders bearing a U.S. address. Containers or holders of imported merchandise bearing the name and address of an... shaped or fitted to contain a specific good or set of goods such as a camera case or an eyeglass case, or...

  8. CFD analysis of a scramjet combustor with cavity based flame holders

    Science.gov (United States)

    Kummitha, Obula Reddy; Pandey, Krishna Murari; Gupta, Rajat

    2018-03-01

    Numerical analysis of a scramjet combustor with different cavity flame holders has been carried out using ANSYS 16 - FLUENT tool. In this research article the internal fluid flow behaviour of the scramjet combustor with different cavity based flame holders have been discussed in detail. Two dimensional Reynolds-Averaged Navier-Stokes governing(RANS) equations and shear stress turbulence (SST) k - ω model along with finite rate/eddy dissipation chemistry turbulence have been considered for modelling chemical reacting flows. Due to the advantage of less computational time, global one step reaction mechanism has been used for combustion modelling of hydrogen and air. The performance of the scramjet combustor with two different cavities namely spherical and step cavity has been compared with the standard DLR scramjet. From the comparison of numerical results, it is found that the development of recirculation regions and additional shock waves from the edge of cavity flame holder is increased. And also it is observed that with the cavity flame holder the residence time of air in the scramjet combustor is also increased and achieved stabilized combustion. From this research analysis, it has been found that the mixing and combustion efficiency of scramjet combustor with step cavity design is optimum as compared to other models.

  9. Effect of Holder pasteurization and frozen storage on macronutrients and energy content of breast milk.

    Science.gov (United States)

    García-Lara, Nadia Raquel; Vieco, Diana Escuder; De la Cruz-Bértolo, Javier; Lora-Pablos, David; Velasco, Noelia Ureta; Pallás-Alonso, Carmen Rosa

    2013-09-01

    The aim of this study was to explore the effect of Holder pasteurization and frozen storage at -20°C after pasteurization on fat, total nitrogen, lactose, and energy content of breast milk. Both procedures are routinely practiced in human milk banks. A total of 34 samples of frozen breast milk, donated by 28 women, were collected. Once thawed, an aliquot of each sample was analyzed before pasteurization; the remaining milk was pasteurized (Holder method) and split into 8 aliquots. One aliquot was analyzed after pasteurization and the remainder frozen at -20°C and analyzed 30, 60, 90, 120, and 180 days later. For every aliquot, fat, total nitrogen, lactose, and energy content were determined using the device human Milk Analyzer. We observed a significant reduction in fat (3.5%; -0.17 (-0.29; -0.04) g/dL) and energy content (2.8%; -2.03 (-3.60; -0.46) g/dL) after pasteurization. A significant decrease over time was observed for fat, lactose and energy content. No significant changes were observed for nitrogen content. Mean differences between day 0 postpasteurization and day 180 were -0.13 (-0.21; -0.06) g/dL for fat, -0.08 (-0.13; -0.03) g/dL for lactose, and -1.55 (-2.38; -0.71) kcal/dL for energy content. The relative decreases were 2.8%, 1.7%, and 2.2%, respectively. Overall (postpasteurization + frozen storage), a 6.2% and 5% decrease were observed for fat and energy, respectively. Holder pasteurization decreased fat and energy content of human milk. Frozen storage at -20°C of pasteurized milk significantly reduced fat, lactose, and energy content of human milk.

  10. SU-E-I-55: The Contribution to Skin Dose Due to Scatter From the Patient Table and the Head Holder During Fluoroscopy

    International Nuclear Information System (INIS)

    Islam, N; Xiong, Z; Vijayan, S; Rudin, S; Bednarek, D

    2015-01-01

    Purpose: To determine contributions to skin dose due to scatter from the table and head holder used during fluoroscopy, and also to explore alternative design material to reduce the scatter dose. Methods: Measurements were made of the primary and scatter components of the xray beam exiting the patient table and a cylindrical head holder used on a Toshiba Infinix c-arm unit as a function of kVp for the various beam filters on the machine and for various field sizes. The primary component of the beam was measured in air with the object placed close to the x-ray tube with an air gap between it and a 6 cc parallel-plate ionization chamber and with the beam collimated to a size just larger than the chamber. The primary plus scatter radiation components were measured with the object moved to a position in the beam next to the chamber for larger field sizes. Both sets of measurements were preformed while keeping the source-to-chamber distance fixed. The scatter fraction was estimated by taking the ratio of the difference between the two measurements and the reading that included both primary and scatter. Similar measurements were also made for a 2.3 cm thick Styrofoam block which could substitute for the patient support. Results: The measured scatter fractions indicate that the patient table as well as the head holder contributes an additional 10–16% to the patient entrance dose depending on field size. Forward scatter was reduced with the Styrofoam block so that the scatter fraction was about 4–5%. Conclusion: The results of this investigation demonstrated that scatter from the table and head holder used in clinical fluoroscopy contribute substantially to the skin dose. The lower contribution of scatter from Styrofoam suggests that there is an opportunity to redesign patient support accessories to reduce the skin dose. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corporation Equipment Grant

  11. SU-E-I-55: The Contribution to Skin Dose Due to Scatter From the Patient Table and the Head Holder During Fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Islam, N; Xiong, Z; Vijayan, S; Rudin, S; Bednarek, D [Toshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY (United States)

    2015-06-15

    Purpose: To determine contributions to skin dose due to scatter from the table and head holder used during fluoroscopy, and also to explore alternative design material to reduce the scatter dose. Methods: Measurements were made of the primary and scatter components of the xray beam exiting the patient table and a cylindrical head holder used on a Toshiba Infinix c-arm unit as a function of kVp for the various beam filters on the machine and for various field sizes. The primary component of the beam was measured in air with the object placed close to the x-ray tube with an air gap between it and a 6 cc parallel-plate ionization chamber and with the beam collimated to a size just larger than the chamber. The primary plus scatter radiation components were measured with the object moved to a position in the beam next to the chamber for larger field sizes. Both sets of measurements were preformed while keeping the source-to-chamber distance fixed. The scatter fraction was estimated by taking the ratio of the difference between the two measurements and the reading that included both primary and scatter. Similar measurements were also made for a 2.3 cm thick Styrofoam block which could substitute for the patient support. Results: The measured scatter fractions indicate that the patient table as well as the head holder contributes an additional 10–16% to the patient entrance dose depending on field size. Forward scatter was reduced with the Styrofoam block so that the scatter fraction was about 4–5%. Conclusion: The results of this investigation demonstrated that scatter from the table and head holder used in clinical fluoroscopy contribute substantially to the skin dose. The lower contribution of scatter from Styrofoam suggests that there is an opportunity to redesign patient support accessories to reduce the skin dose. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corporation Equipment Grant.

  12. Punishability of office-holders in environmental law

    International Nuclear Information System (INIS)

    Papier, H.J.

    1988-01-01

    The author deals with the question of criminal responsibility of office-holders in the field of environmental law. The provisions in secs. 324-330 of the Penal Code do not grant independent or origin protection from violation of the law. They depend on administrative law regulations. (WG) [de

  13. Evaluation of the BD Vacutainer Plus Urine C&S Preservative Tubes compared with nonpreservative urine samples stored at 4°C and room temperature.

    Science.gov (United States)

    Eisinger, Stephen W; Schwartz, Matthew; Dam, Lisa; Riedel, Stefan

    2013-09-01

    The stability of urine specimens submitted for culture remains a challenge for many laboratories because of delays in specimen transport. We evaluated the usefulness of BD Vacutainer Plus Urine C&S Preservative Tube in ensuring specimen stability. Clinical urine specimens collected in sterile collection cups (n = 110) were plated onto sheep blood and MacConkey agar following standard laboratory procedures guidelines. Thereafter, specimens were divided into 3 storage conditions: nonpreservative, refrigerated; nonpreservative, room temperature (RT); BD Vacutainer Plus Urine C&S Preservative Tube, RT. For each sample type, additional cultures were set up at 2, 4, 24, and 48 hours. Initially, 18 specimens had no growth, 32 showed mixed skin flora, and 60 yielded at least 1 uropathogen. Increased colony counts of uropathogens were observed for nonpreserved urine samples stored at RT; these changes were statistically significant. Minor differences between refrigerated urine samples and BD Vacutainer Plus Urine C&S Preservative Tube samples were seen but were not statistically significant. The use of preservative-containing collection tubes is desirable to ensure specimen stability when prompt processing or refrigeration is not feasible.

  14. Highly identified power-holders feel responsible: The interplay between social identification and social power within groups.

    Science.gov (United States)

    Scholl, Annika; Sassenberg, Kai; Ellemers, Naomi; Scheepers, Daan; de Wit, Frank

    2018-01-01

    Power relations affect dynamics within groups. Power-holders' decisions not only determine their personal outcomes, but also the outcomes of others in the group that they control. Yet, power-holders often tend to overlook this responsibility to take care of collective interests. The present research investigated how social identification - with the group to which both the powerful and the powerless belong - alters perceived responsibility among power-holders (and the powerless). Combining research on social power and social identity, we argue that power-holders perceive more responsibility than the powerless when strongly (rather than when weakly) identifying with the group. A study among leaders and an experiment supported this, highlighting that although power-holders are often primarily concerned about personal outcomes, they do feel responsible for considering others' interests when these others are included in the (social) self. © 2017 The British Psychological Society.

  15. Darfur and the flaws of Holder v HLP

    Directory of Open Access Journals (Sweden)

    Christopher Thornton

    2011-03-01

    Full Text Available When US Chief Justice Roberts handed down the judgment in Holder v Humanitarian Law Project, he revealed the Supreme Court’s tragic under-estimation of the potential of engagement with non-state armed groups....

  16. The Outcome of Thoracentesis versus Chest Tube Placement for Hepatic Hydrothorax in Patients with Cirrhosis: A Nationwide Analysis of the National Inpatient Sample

    Directory of Open Access Journals (Sweden)

    Ali Ridha

    2017-01-01

    Full Text Available There are only a few studies with a small sample size of patients that have compared the risks of using chest tubes versus thoracentesis in hepatic hydrothorax. It has been shown that many complications may arise secondary to chest tube placement and is associated with increased morbidity and mortality. In this retrospective study, patients with cirrhosis were identified from the 2009 National Inpatient Sample by using ICD-9 codes; we evaluated the risk of chest tube versus thoracentesis in a largest population with hepatic hydrothorax to date to measure the mortality and the length of stay. A total of 140,573 patients with liver cirrhosis were identified. Of this, 1981 patients had a hepatic hydrothorax and ended up with either thoracentesis (1776 or chest tube (205. The mortality in those who received a chest tube was two times higher than that in thoracentesis group with a P value of ≤0.001 (CI 1.43–312. In addition, the length of hospital stay of the chest tube group was longer than that of the thoracentesis subset (7.2 days versus 3.8 days, resp.. We concluded that chest tube placement has two times higher mortality rate and longer hospital length of stay when compared to patients who underwent thoracentesis.

  17. Selective molecularly imprinted polymer combined with restricted access material for in-tube SPME/UHPLC-MS/MS of parabens in breast milk samples.

    Science.gov (United States)

    Souza, Israel D; Melo, Lidervan P; Jardim, Isabel C S F; Monteiro, Juliana C S; Nakano, Ana Marcia S; Queiroz, Maria Eugênia C

    2016-08-17

    A new molecularly imprinted polymer modified with restricted access material (a hydrophilic external layer), (MIP-RAM) was synthesized via polymerization in situ in an open fused silica capillary. This stationary phase was used as sorbent for in-tube solid phase microextraction (in-tube SPME) to determine parabens in breast milk samples by ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Scanning electron micrographs (SEM) illustrate MIP surface modification after glycerol dimethacrylate (hydrophilic monomer) incorporation. The interaction between parabens and MIP-RAM was investigated by Fourier-transform infrared (FTIR) spectroscopy. The Scatchard plot for MIP-RAM presented two linear parts with different slopes, illustrating binding sites with high- and low-affinity. Endogenous compounds exclusion from the MIP-RAM capillary was demonstrated by in-tube SPME/LC-UV assays carried out with blank milk samples. The in-tube SPME/UHPLC-MS/MS method presented linear range from 10 ng mL(-1) (LLOQ) to 400 ng mL(-1) with coefficients of determination higher than 0.99, inter-assay precision with coefficient of variation (CV) values ranging from 2 to 15%, and inter-assay accuracy with relative standard deviation (RSD) values ranging from -1% to 19%. Analytical validation parameters attested that in-tube SPME/UHPLC-MS/MS is an appropriate method to determine parabens in human milk samples to assess human exposure to these compounds. Analysis of breast milk samples from lactating women demonstrated that the proposed method is effective. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Effect of Holder pasteurization on macronutrients and immunoglobulin profile of pooled donor human milk.

    Science.gov (United States)

    Adhisivam, B; Vishnu Bhat, B; Rao, Krishna; Kingsley, S M; Plakkal, Nishad; Palanivel, C

    2018-03-27

    The objective of this study was to study the effect of Holder pasteurization on macronutrients and immunoglobulin profile of pooled donor human milk. This descriptive study was conducted in a Human Milk Bank of a tertiary care teaching institute in south India. Thirty random paired pooled donor human milk samples (before and after pasteurization) were analyzed for macronutrients (protein, fat, carbohydrates) using infrared spectroscopy. Similarly, immunoglobulin profile (IgA and IgG) before and after pasteurization was quantified using ELISA. The mean values of protein, fat, and carbohydrates in pooled donor milk pre-pasteurization were 1.6, 3.6, and 6.1 g/dl compared with post-pasteurization values 1.4, 2.7, and 5.9 g/dl, respectively. Pasteurization reduced protein, fat, and energy content of pooled donor milk by 12.5%, 25%, and 16%, respectively. However, carbohydrates were not significantly reduced. Pasteurization decreased IgA by 30% and IgG by 60%. Holder pasteurization of pooled donor human milk decreases protein, fat, and energy content and also reduces the levels of IgA and IgG.

  19. STATISTICAL ASSESSMENT OF CAREERS OF DOCTORATE HOLDERS SURVEY BY CORRESPONDENCE ANALYSIS: THE CASE OF TURKEY

    OpenAIRE

    Zerrin AŞAN GREENACRE

    2018-01-01

    Nowadays, doctorate holders are not only academician and researcher, also they play roles across a wide range of working areas within society. These areas are increasing multiway. The aim of this study is to give statistical evaluation careers of doctorate holders survey using  the correspondence analysis with supplementary variables. In this paper  we focused on careers of doctorate holders  in Turkey. It was held a survey by  Turkish   Statistical Institute on this s...

  20. 14 CFR Appendix O to Part 121 - Hazardous Materials Training Requirements For Certificate Holders

    Science.gov (United States)

    2010-01-01

    ... K of this chapter. The training requirements for various categories of persons are defined by job... to persons actually performing the job function. Training requirements for certificate holders.... The method of delivering the training will be determined by the certificate holder. The certificate...

  1. 7 CFR 762.144 - Repurchase of guaranteed portion from a secondary market holder.

    Science.gov (United States)

    2010-01-01

    ... discrepancy is resolved. (iii) In the case of a request for Agency purchase, the Agency will only pay interest... and the amount due the holder. (ii) Any discrepancy between the amount claimed by the holder and the... approved by the Agency. The Agency will not participate in resolution of any such discrepancy. When there...

  2. Thermal Stress FE Analysis of Large-scale Gas Holder Under Sunshine Temperature Field

    Science.gov (United States)

    Li, Jingyu; Yang, Ranxia; Wang, Hehui

    2018-03-01

    The temperature field and thermal stress of Man type gas holder is simulated by using the theory of sunshine temperature field based on ASHRAE clear-sky model and the finite element method. The distribution of surface temperature and thermal stress of gas holder under the given sunshine condition is obtained. The results show that the thermal stress caused by sunshine can be identified as one of the important factors for the failure of local cracked oil leakage which happens on the sunny side before on the shady side. Therefore, it is of great importance to consider the sunshine thermal load in the stress analysis, design and operation of large-scale steel structures such as the gas holder.

  3. Mechanical Conversion for High-Throughput TEM Sample Preparation

    International Nuclear Information System (INIS)

    Kendrick, Anthony B; Moore, Thomas M; Zaykova-Feldman, Lyudmila

    2006-01-01

    This paper presents a novel method of direct mechanical conversion from lift-out sample to TEM sample holder. The lift-out sample is prepared in the FIB using the in-situ liftout Total Release TM method. The mechanical conversion is conducted using a mechanical press and one of a variety of TEM coupons, including coupons for both top-side and back-side thinning. The press joins a probe tip point with attached TEM sample to the sample coupon and separates the complete assembly as a 3mm diameter TEM grid, compatible with commercially available TEM sample holder rods. This mechanical conversion process lends itself well to the high through-put requirements of in-line process control and to materials characterization labs where instrument utilization and sample security are critically important

  4. Position of document holder and work related risk factors for neck pain among computer users: a narrative review.

    Science.gov (United States)

    Ambusam, S; Baharudin, O; Roslizawati, N; Leonard, J

    2015-01-01

    Document holder is used as a remedy to address occupational neck pain among computer users. An understanding on the effects of the document holder along with other work related risk factors while working in computer workstation requires attention. A comprehensive knowledge on the optimal location of the document holder in computer use and associated work related factors that may contribute to neck pain reviewed in this article. A literature search has been conducted over the past 14 years based on the published articles from January 1990 to January 2014 in both Science Direct and PubMed databases. Medical Subject Headings (MeSH) keywords for search were neck muscle OR head posture OR muscle tension' OR muscle activity OR work related disorders OR neck pain AND/OR document location OR document holder OR source document OR copy screen holder.Document holder placed lateral to the screen was most preferred to reduce neck discomfort among occupational typists. Document without a holder was placed flat on the surface is least preferred. The head posture and muscle activity increases when the document is placed flat on the surface compared to when placed on the document holder. Work related factors such as static posture, repetitive movement, prolong sitting and awkward positions were the risk factors for chronic neck pain. This review highlights the optimal location for document holder for computer users to reduce neck pain. Together, the importance of work related risk factors for to neck pain on occupational typist is emphasized for the clinical management.

  5. The YouTube Jihadists: A Social Network Analysis of Al-Muhajiroun’s Propaganda Campaign

    Directory of Open Access Journals (Sweden)

    Jytte Klausen

    2012-03-01

    Full Text Available Producers of Al-Qaeda inspired propaganda have shifted their operations in recent years from closed membership online forums to mainstream social networking platforms. Using social network analysis, we show that behind the apparent proliferation of such sources, YouTube account holders associated with incarnations of the British al-Muhajiroun collude to post propaganda and violent content. European groups commonly use American platforms and domain names registered with American companies. Seeking shelter under speech rights granted by the First Amendment, they evade European laws against incitement and hate speech.

  6. Sampling inspection device

    International Nuclear Information System (INIS)

    Chiba, Keiichi.

    1996-01-01

    A holder is inserted to a holder guide, and is stopped at a position where one end of a hook disposed to the holder is not in contact with the holder guide (a position where hooks do not work). A cap incorporated with wiping paper is pushed up into a holder by a device rod with the wiping paper situated downwardly. The hooks of the holder are engaged to the grooves of the cap to secure the cap. The holder is moved to a predetermined place to wipe off the deposited materials on the surface of a vessel which contains radioactive wastes. Then, the holder is inserted to the holder guide, and is stopped at a position where the one end of the holder is raised. The securement of the gap is released, the cap is forced into a recovering cover by a discharging rod. The hooks of the recovering cover are caught by the grooves of the cap to secure the cap. Then, the cap is transported to a radioactivity measuring chamber. (I.N.)

  7. Gender differentials in market participation among small-holder ...

    African Journals Online (AJOL)

    Gender differentials in market participation among small-holder cassava farmers ... The results showed that the female farmers participated and sold more cassava in the market than their male counterparts. ... facilitate faster delivery of farm produce especially perishable commodities such as ... AJOL African Journals Online.

  8. Investigation of a flame holder geometry effect on flame structure in non-premixed combustion

    International Nuclear Information System (INIS)

    Hashemi, S. A.; Hajialigol, N.; Fattahi, A.; Heydari, R.; Mazaheri, K.

    2013-01-01

    In this paper the effect of flame holder geometry on flame structure is studied. The obtained numerical results using realizable k-ε and β-PDF models show a good agreement with experimental data. The results show that increasing in flame holder length decreases flame length and increases flame temperature. Additionally, it is observed that flame lengths decrease by increasing in flame holder radius and increase for larger radii. Furthermore in various radii, the flame temperature is higher for smaller flame lengths. It was found that behavior of flame structure is mainly affected by the mass flow rate of hot gases that come near the reactant by the recirculation zone.

  9. Investigation of a flame holder geometry effect on flame structure in non-premixed combustion

    Energy Technology Data Exchange (ETDEWEB)

    Hashemi, S. A.; Hajialigol, N.; Fattahi, A.; Heydari, R. [University of Kashan, Kashan (Iran, Islamic Republic of); Mazaheri, K. [University of Tarbiat Moddares, Tehran (Iran, Islamic Republic of)

    2013-11-15

    In this paper the effect of flame holder geometry on flame structure is studied. The obtained numerical results using realizable k-ε and β-PDF models show a good agreement with experimental data. The results show that increasing in flame holder length decreases flame length and increases flame temperature. Additionally, it is observed that flame lengths decrease by increasing in flame holder radius and increase for larger radii. Furthermore in various radii, the flame temperature is higher for smaller flame lengths. It was found that behavior of flame structure is mainly affected by the mass flow rate of hot gases that come near the reactant by the recirculation zone.

  10. Development of a Test to Evaluate Aerothermal Response of Materials to Hypersonic Flow Using a Scramjet Wind Tunnel (Postprint)

    Science.gov (United States)

    2010-05-01

    prevent the possible slip of the sample within the dovetail. The dovetail holder was made of inconel and was attached to the tube by TIG welding . Moni...Composite Materials and Processing Section Composite Materials and Processing Section Composite Branch...dovetail ( welded ) 0.775" 0.156" hole Coolant (water) Set screws 0.625" OD 0.049" wall TBC Cooled metallic holder Ceramic TC Fig. 4. Schematic sketches of

  11. Test sample handling apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    A test sample handling apparatus using automatic scintillation counting for gamma detection, for use in such fields as radioimmunoassay, is described. The apparatus automatically and continuously counts large numbers of samples rapidly and efficiently by the simultaneous counting of two samples. By means of sequential ordering of non-sequential counting data, it is possible to obtain precisely ordered data while utilizing sample carrier holders having a minimum length. (U.K.)

  12. The Effect of Holder Pasteurization on Activin A Levels in Human Milk.

    Science.gov (United States)

    Peila, Chiara; Coscia, Alessandra; Bertino, Enrico; Li Volti, Giovanni; Galvano, Fabio; Barbagallo, Ignazio; Visser, Gerard H A; Gazzolo, Diego

    2016-11-01

    There is evidence that mother's own milk is the best nutrient in terms of multiorgan protection and infection prevention. However, when maternal milk is scarce, the solution can be represented by donor milk (DM), which requires specific storage procedures such as Holder Pasteurization (HoP). HoP is not free from side effects since it is widely known that it causes qualitative/quantitative changes in milk composition, particularly in the protein content. Therefore, the aim of this study is to investigate the effects of HoP on Activin A, a neurobiomarker known to play an important role in the development and protection of the central nervous system. In 24 mothers who delivered preterm (n = 12) and term (n = 12) healthy newborns, we conducted a pretest/test study where the milk donors acted as their own controls. Each sample was divided into two parts: the first was frozen at -80°C (Group 1); the second was Holder-pasteurized before freezing at -80°C (Group 2). Activin A was quantified using an ELISA test. Activin A was detected in all samples. There were no significant differences (p > 0.05) between the two groups, also when the analysis was stratified for gestational age at delivery and milk maturation degree (p > 0.05, for both). The present findings on the absence of any side effects of HoP on the milk concentration of Activin A offer additional support to the efficacy of HoP in DM storage. Our data open up to further investigations on neurobiomarkers' assessment in human milk and their preanalytical stability according to storage procedures.

  13. Research Amplitudo Vibration On Holder Due To The Process Of Lathe Nozzle Rocket RX 450

    Science.gov (United States)

    Ediwan; Budi Djatmiko, Agus; Dody Arisandi, EfFendy; Purnomo, Heri; Ibadi, Mahfud

    2018-04-01

    The main function of the rocket nozzle is to convert the enthalpy efficiency from combustion gas to kinetic energy and also to make high velocity out of the gas. The rocket nozzle usually consists of a converging and diverging part. With a smaller area on the neck and enlarged at the exit area. The velocity flow through the nozzle enlarges into the speed of sound through the neck and then becomes super sonic in the divergent part. Nozzle making or machining using conventional lathes, first performed is drilling on a massive metal that is bonded to the veneer, then after a sufficient gap is done deep-boring. At the time of the process of lathe in the nozzle RX 450 there is an obstacle that is vibrating tool holder chisel or holder so it is worried about not precision of the process of lathe. This should not happen because it can cause failure in the latter for it needs to be studied and studied further so that the lathe process goes accordingly. The holder material of ST 60 with a modulus of elasticity 200 GPa and a nozzle material of AISI 4340 alloy steel with σyield = 470 MPa, Shear Modulus G = 80 GPa. The purpose of this research is to observe the amplitude of vibration on the holder due to RX- 450 nozzle lathe processing for the purpose of amplitude that occurs in accordance with the desired so that the nozzle structure is no damage process. The result of the research was obtained holder with length (L) 80cm, profile width (B) 5 cm, height of profile (H) 10 cm, turning machine ω = 8.98 rad / sec and natural holder frequency ωn = 89.8 rad / second, Amplitude of vibration of δ = 1.21 mm, while the amplitude of the design X = 1.22 mm From the results of this study it can be said that the holder of a chisel or holder can be used as a tool at the time of RX nozzle retrieval process and is quite safe because it works under the condition ω/ω n Rocket Payload "AKPV Engineering University of Wyoming 2009 )

  14. Optimization of a spectrometry for energy-dispersive x-ray fluorescence analysis by x-ray tube in combination with secondary target for multielements determination of sediment samples

    International Nuclear Information System (INIS)

    Zaidi Embong; Husin Wagiran

    1997-01-01

    The design of an energy-dispersive X-ray fluorescence spectrometer equipped with a conventional X-ray tube and secondary target is described. The spectrometer system constructed in our laboratory consists of a semiconductor detector system, irradiation chamber and X-ray tube. Primary source from X-ray tube was used to produced secondary X-ray from selenium, molybdenum and cadmium targets. The fluorescence X-ray from the sample was detected using Si(Li) detector with resolution of 0. 175 keV (Mn-K(x). The spectrometer was used for determination of multi-elements with atomic number between 20 to 44 in river sediment samples. The X-ray spectrum, from the samples were analysed using computer software which was developed based on Marquardt method. Optimal conditions and detection limits are determined experimentally by variation of excitation parameters for each combination of secondary target and tube voltage

  15. Hybrid friction diffusion bonding of 316L stainless steel tube-to-tube sheet joints for coil-wound heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Haneklaus, Nils; Cionea, Cristian; Reuven, Rony; Frazer, David; Hosemann, Peter; Peterson, Per F. [Dept of Nuclear Engineering, University of California, Berkeley (United States)

    2016-11-15

    Hybrid friction diffusion bonding (HFDB) is a solid-state bonding process first introduced by Helmholtz-Zentrum Geesthacht to join aluminum tube-to-tube sheet joints of Coil-wound heat exchangers (CWHE). This study describes how HFDB was successfully used to manufacture 316L test samples simulating tube-to-tube sheet joints of stainless steel CWHE for molten salt coolants as foreseen in several advanced nuclear- and thermal solar power plants. Engineering parameters of the test sample fabrication are presented and results from subsequent non-destructive vacuum decay leak testing and destructive tensile pull-out testing are discussed. The bonded areas of successfully fabricated samples as characterized by tube rupture during pull-out tensile testing, were further investigated using optical microscopy and scanning electron microscopy including electron backscatter diffraction.

  16. A MEMS-based heating holder for the direct imaging of simultaneous in-situ heating and biasing experiments in scanning/transmission electron microscopes.

    Science.gov (United States)

    Mele, Luigi; Konings, Stan; Dona, Pleun; Evertz, Francis; Mitterbauer, Christoph; Faber, Pybe; Schampers, Ruud; Jinschek, Joerg R

    2016-04-01

    The introduction of scanning/transmission electron microscopes (S/TEM) with sub-Angstrom resolution as well as fast and sensitive detection solutions support direct observation of dynamic phenomena in-situ at the atomic scale. Thereby, in-situ specimen holders play a crucial role: accurate control of the applied in-situ stimulus on the nanostructure combined with the overall system stability to assure atomic resolution are paramount for a successful in-situ S/TEM experiment. For those reasons, MEMS-based TEM sample holders are becoming one of the preferred choices, also enabling a high precision in measurements of the in-situ parameter for more reproducible data. A newly developed MEMS-based microheater is presented in combination with the new NanoEx™-i/v TEM sample holder. The concept is built on a four-point probe temperature measurement approach allowing active, accurate local temperature control as well as calorimetry. In this paper, it is shown that it provides high temperature stability up to 1,300°C with a peak temperature of 1,500°C (also working accurately in gaseous environments), high temperature measurement accuracy (in-situ S/TEM imaging experiments, but also elemental mapping at elevated temperatures using energy-dispersive X-ray spectroscopy (EDS). Moreover, it has the unique capability to enable simultaneous heating and biasing experiments. © 2016 Wiley Periodicals, Inc.

  17. Building lab-scale x-ray tube based irradiators

    International Nuclear Information System (INIS)

    Haff, Ron; Jackson, Eric; Gomez, Joseph; Light, Doug; Follett, Peter; Simmons, Greg; Higbee, Brad

    2016-01-01

    Here we report the use of x-ray tube based irradiators as alternatives to gamma sources for laboratory scale irradiation. Irradiators were designed with sample placement in closest possible proximity to the source, allowing high dose rates for small samples. Designs using 1000 W x-ray tubes in single tube, double tube, and four tube configurations are described, as well as various cabinet construction techniques. Relatively high dose rates were achieved for small samples, demonstrating feasibility for laboratory based irradiators for research purposes. Dose rates of 9.76, 5.45, and 1.7 Gy/min/tube were measured at the center of a 12.7 cm container of instant rice at 100 keV, 70 keV, and 40 keV, respectively. Dose uniformity varies dramatically as the distance from source to container. For 2.54 cm diameter sample containers containing adult Navel Orangeworm, dose rates of 50–60 Gy/min were measured in the four tube system. - Highlights: • X-ray is demonstrated as an alternative to gamma for lab-based irradiation. • Cabinets using one, two, and four 1000 W tubes are reported. • Dose rate of 9.8 Gy/min/tube at the center of a 12.7 cm container of instant rice. • Dose uniformity varies dramatically as the distance from source to container.

  18. 78 FR 9720 - Agency Information Collection Activities: Holders or Containers Which Enter the United States...

    Science.gov (United States)

    2013-02-11

    ... Activities: Holders or Containers Which Enter the United States Duty Free AGENCY: U.S. Customs and Border... or Containers which enter the United States Duty Free. This is a proposed extension of an information..., or other technological techniques or other forms of information. Title: Holders or Containers which...

  19. 32 CFR 767.9 - Content of permit holder's final report.

    Science.gov (United States)

    2010-07-01

    ... RULES APPLICATION GUIDELINES FOR ARCHEOLOGICAL RESEARCH PERMITS ON SHIP AND AIRCRAFT WRECKS UNDER THE.... The permit holder's final report shall include the following: (a) A site history and a contextual...

  20. Socio-economic characteristics of small-holder farmers influencing ...

    African Journals Online (AJOL)

    Socio-economic characteristics of small-holder farmers influencing their utilisation of microcredit in the central agricultural zone of Cross River state. ... The findings revealed that about thirty – four percent (33.6%) of the crop farmers fell between 41-50 years while about 51% of the livestock farmers fell between 31-40 years.

  1. Biological sample collector

    Science.gov (United States)

    Murphy, Gloria A [French Camp, CA

    2010-09-07

    A biological sample collector is adapted to a collect several biological samples in a plurality of filter wells. A biological sample collector may comprise a manifold plate for mounting a filter plate thereon, the filter plate having a plurality of filter wells therein; a hollow slider for engaging and positioning a tube that slides therethrough; and a slide case within which the hollow slider travels to allow the tube to be aligned with a selected filter well of the plurality of filter wells, wherein when the tube is aligned with the selected filter well, the tube is pushed through the hollow slider and into the selected filter well to sealingly engage the selected filter well and to allow the tube to deposit a biological sample onto a filter in the bottom of the selected filter well. The biological sample collector may be portable.

  2. Study on the influence of X-ray tube spectral distribution on the analysis of bulk samples and thin films: Fundamental parameters method and theoretical coefficient algorithms

    International Nuclear Information System (INIS)

    Sitko, Rafal

    2008-01-01

    Knowledge of X-ray tube spectral distribution is necessary in theoretical methods of matrix correction, i.e. in both fundamental parameter (FP) methods and theoretical influence coefficient algorithms. Thus, the influence of X-ray tube distribution on the accuracy of the analysis of thin films and bulk samples is presented. The calculations are performed using experimental X-ray tube spectra taken from the literature and theoretical X-ray tube spectra evaluated by three different algorithms proposed by Pella et al. (X-Ray Spectrom. 14 (1985) 125-135), Ebel (X-Ray Spectrom. 28 (1999) 255-266), and Finkelshtein and Pavlova (X-Ray Spectrom. 28 (1999) 27-32). In this study, Fe-Cr-Ni system is selected as an example and the calculations are performed for X-ray tubes commonly applied in X-ray fluorescence analysis (XRF), i.e., Cr, Mo, Rh and W. The influence of X-ray tube spectra on FP analysis is evaluated when quantification is performed using various types of calibration samples. FP analysis of bulk samples is performed using pure-element bulk standards and multielement bulk standards similar to the analyzed material, whereas for FP analysis of thin films, the bulk and thin pure-element standards are used. For the evaluation of the influence of X-ray tube spectra on XRF analysis performed by theoretical influence coefficient methods, two algorithms for bulk samples are selected, i.e. Claisse-Quintin (Can. Spectrosc. 12 (1967) 129-134) and COLA algorithms (G.R. Lachance, Paper Presented at the International Conference on Industrial Inorganic Elemental Analysis, Metz, France, June 3, 1981) and two algorithms (constant and linear coefficients) for thin films recently proposed by Sitko (X-Ray Spectrom. 37 (2008) 265-272)

  3. A new holder and surface MRI coil for the examination of the newborn infant hip

    Energy Technology Data Exchange (ETDEWEB)

    Krasny, R. (Dept. of Diagnostic Radiology, Univ. of Technology, Aachen (Germany)); Casser, H.R. (Dept. of Orthopedics, Univ. of Technology, Aachen (Germany)); Requardt, H. (Siemens AG, Erlangen (Germany)); Botschek, A. (Dept. of Diagnostic Radiology, Univ. of Technology, Aachen (Germany))

    1993-11-01

    A special holder was developed for examination of the infant hip joint using MRI. This holder allows the infant hip joint to be examined both in a neutral position and in various defined functional positions. A special integrated surface coil, also developed for this purpose, provides the high spatial resolution required for assessment of the fine joint structures. Thirty infants were examined and the new device has proved useful in advanced hip dysplasia, therapy-resistant subluxation and luxation, and for operative therapy planning (reconstruction of the acetabular roof, redirectional osteotomies). Interpretation errors due to misprojection can be eliminated to a large extent since the holder allows standardized and reproducible positioning. (orig.)

  4. Preparation and evaluation of a novel molecularly imprinted polymer coating for selective extraction of indomethacin from biological samples by electrochemically controlled in-tube solid phase microextraction

    Energy Technology Data Exchange (ETDEWEB)

    Asiabi, Hamid [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Yamini, Yadollah, E-mail: yyamini@modares.ac.ir [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Seidi, Shahram; Ghahramanifard, Fazel [Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, Tehran (Iran, Islamic Republic of)

    2016-03-24

    In the present work, an automated on-line electrochemically controlled in-tube solid-phase microextraction (EC-in-tube SPME) coupled with HPLC-UV was developed for the selective extraction and preconcentration of indomethacin as a model analyte in biological samples. Applying an electrical potential can improve the extraction efficiency and provide more convenient manipulation of different properties of the extraction system including selectivity, clean-up, rate, and efficiency. For more enhancement of the selectivity and applicability of this method, a novel molecularly imprinted polymer coated tube was prepared and applied for extraction of indomethacin. For this purpose, nanostructured copolymer coating consisting of polypyrrole doped with ethylene glycol dimethacrylate was prepared on the inner surface of a stainless-steel tube by electrochemical synthesis. The characteristics and application of the tubes were investigated. Electron microscopy provided a cross linked porous surface and the average thickness of the MIP coating was 45 μm. Compared with the non-imprinted polymer coated tubes, the special selectivity for indomethacin was discovered with the molecularly imprinted coated tube. Moreover, stable and reproducible responses were obtained without being considerably influenced by interferences commonly existing in biological samples. Under the optimal conditions, the limits of detection were in the range of 0.07–2.0 μg L{sup −1} in different matrices. This method showed good linearity for indomethacin in the range of 0.1–200 μg L{sup −1}, with coefficients of determination better than 0.996. The inter- and intra-assay precisions (RSD%, n = 3) were respectively in the range of 3.5–8.4% and 2.3–7.6% at three concentration levels of 7, 70 and 150 μg L{sup −1}. The results showed that the proposed method can be successfully applied for selective analysis of indomethacin in biological samples. - Graphical abstract: An automated on

  5. Warm Deep Drawing of Rectangular Parts of AZ31 Magnesium Alloy Sheet Adopting Variable Blank Holder Force

    International Nuclear Information System (INIS)

    Peng Yinghong; Chang Qunfeng; Li Dayong; Zeng Xiaoqin

    2007-01-01

    AZ31 magnesium alloy sheet with good shape and formability is fabricated by warm cross rolling. Uniaxial tensile tests are conducted using a Gleeble 3500 thermal - mechanical simulator, and the mechanical properties of AZ31 magnesium alloy sheet are analyzed. A warm deep drawing process of square part is also simulated by the finite element method. The influences of blank holder force on the formability are numerically investigated. A double-action hydraulic press that can realize adjustable blank holder forces is developed and its working principle and control system are introduced. Some warm deep drawing experiments of square parts of AZ31 magnesium alloy sheet are also performed. Different variation schemes of the blank holder force with the stroke of the punch are tested, and the experiment results are compared. Results show that the suitable blank holder force variation scheme is a ladder curve with the punch stroke. Adopting the variable blank holder force technique can improve 13.2% of the drawing depth of square parts of AZ31 magnesium alloy sheet

  6. Humid scraping method to obtain samples for the analysis of D2 incorporated in the pressure tubes of Embalse Nuclear Power Plant

    International Nuclear Information System (INIS)

    Binetti, Edgardo O.; Cerutti, Carlos R.

    1999-01-01

    From ten fuel channels of the CNE reactor four samples of each channel were taken by means of the Humid Scraping method in order to evaluate the equivalent hydrogen content by incorporating deuterium in the pressure tubes. With these data, it is possible to make a list of priorities of channels for future replacement of spacer rings between pressure and calandria tubes, using Slarette equipment. (author)

  7. Development of a dedicated front-end electronics for straw tube trackers in the bar PANDA experiment

    Science.gov (United States)

    Przyborowski, D.; Fiutowski, T.; Idzik, M.; Kajetanowicz, M.; Korcyl, G.; Salabura, P.; Smyrski, J.; Strzempek, P.; Swientek, K.; Terlecki, P.; Tokarz, J.

    2016-08-01

    The design and tests of front-end electronics for straw tube trackers in the bar PANDA experiment at FAIR are presented. The challenges for the front-end electronics, comprising operation at high counting rate up to 1 MHz per straw tube, are discussed and the proposed architecture comprising a switched gain charge sensitive preamplifier (CSP), a pole-zero cancellation circuit (PZC), a second order variable peaking time shaper, a trimming ion tail cancellation circuit, and a baseline holder (BLH), is described. The front-end provides an analogue output and a discriminator with LVDS differential driver for the Time-of-Arrival (ToA) and Time-over-Threshold (ToT) measurements. A prototype readout ASIC featuring four channels was fabricated in 0.35 μm CMOS technology consuming 15.5 mW (analog part) and 12 mW (LVDS) per channel. The results of measurements of peaking time (25-67 ns), gain, noise (ENC 800-2500 el. for various gains), time walk and jitter are presented as well as the first results obtained with prototype straw tubes connected.

  8. Scintillation counter: photomultiplier tube alignment

    International Nuclear Information System (INIS)

    Olson, R.E.

    1975-01-01

    A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into the sample receiving zone. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (auth)

  9. Tissue reactions to bacteria-inoculated rat lead samples .2. Effect of local gentamicin release through surface-modified polyurethane tubing

    NARCIS (Netherlands)

    vanWachem, PB; vanLuyn, MJA; deWit, AW; Raatjes, D; Hendriks, M; Verhoeven, MLPM; Cahalan, PT

    A surface modification technique was developed to achieve controlled release of gentamicin from implanted polyurethane (PU) rat lead samples. PU tubing first was provided with an acrylic acid/acrylamide copolymer surface graft and then loaded with gentamicin. This surface modification technique

  10. Colour coding for blood collection tube closures - a call for harmonisation

    DEFF Research Database (Denmark)

    Simundic, Ana-Maria; Cornes, Michael P; Grankvist, Kjell

    2015-01-01

    including errors in sampling, reporting and decision-making have received much less attention. Proper sampling and additives to the samples are essential. Tubes and additives are identified not only in writing on the tubes but also by the colour of the tube closures. Unfortunately these colours have...... not been standardised, running the risk of error when tubes from one manufacturer are replaced by the tubes from another manufacturer that use different colour coding. EFLM therefore supports the worldwide harmonisation of the colour coding for blood collection tube closures and labels in order to reduce...

  11. Glove holder system for containment shell

    International Nuclear Information System (INIS)

    Picco, B.

    1993-01-01

    A glove holder for an isolated chamber used e.g. for handling toxic or radioactive materials and made with at least one access port in its wall, equipped with a ring to which the glove is attached, has a sleeve which connects the ring to the glove proper and protects the forarm. The sleeve is in at least two sections, a first corrugated section and a second, supple section which is able to fold inside the first section. ADVANTAGE - Reduced costs and quantity of waste produced by enabling glove proper only to be replaced. (author)

  12. [Delayed testing for the diagnosis of fungi in the urines. Evaluation of the BD Vacutainer C&S tubes for the storage of urine samples at room temperature].

    Science.gov (United States)

    Baixench, M T; Al-Sheikh, M; Paugam, A

    2005-01-01

    The study included 37 urine samples which have been artificially infected with low levels (10(3) CFU/mL) of various fungi strains. We compared the effects of sample storage, up to 48 hours, at room temperature, in a urine evacuated tube containing specific additives with storage at + 4 degrees C, for the same length of time, in a urine evacuated tube without any additives. There have been no differences of results (speed of growth and colony size) between the 2 modes of storage. However, the experience has shown that samples needed a careful mixing before seeding to avoid underdetection of the strains. Based on the study results, the BD Vacutainer C&S tubes are suitable for delayed testing for the diagnosis of urine fungal infection.

  13. The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH Plasma tube

    Science.gov (United States)

    Arslan, Fatma Demet; Karakoyun, Inanc; Basok, Banu Isbilen; Aksit, Merve Zeytinli; Baysoy, Anil; Ozturk, Yasemin Kilic; Guclu, Yusuf Adnan; Duman, Can

    2017-01-01

    Introduction Although serum-providing blood tubes with a barrier are still widely used due to their significant advantages, the use of blood tubes with a barrier to provide plasma is becoming widespread. We compared 22 analytes in a BD Vacutainer® Barricor LH Plasma tube for local clinical validation of this new lithium heparin tube with a barrier. Materials and methods Samples from 44 volunteers were collected in different tubes (Becton Dickinson and Company): Z tube without additive (reference), clot-activator tube with gel (SST), lithium heparin tube without gel (LiH), and lithium heparin tube with barrier (Barricor). Analyte concentrations in different tubes were compared with the reference tube. All tubes were also evaluated according to additional testing (different centrifugation durations, blood-sampling techniques and individual differences). Results Aspartate aminotransferase (AST), glucose (Glc), potassium (K), lactate dehydrogenase (LD), sodium (Na), and total protein (TP) had a significant bias in Barricor (9.19%, - 3.24%, - 4.88%, 21.60%, - 0.40%, 5.03%, respectively) relative to the reference tube. There was no statistical difference between different centrifugation durations and individual differences for AST, K and LD in LiH and/or Barricor (P > 0.05). There was a significant bias for LD between LiH and Barricor in terms of blood-sampling techniques (21.2% and 12.4%, respectively). Conclusions Recently, the use of plasma has become prominent due to some of its advantages. In this study, plasma AST, K, LD, Glc and TP levels in Barricor were clinically different in comparison to serum. The results of additional tests showed that higher levels of LD in Barricor did not result from haemolysis, and they might be related to other factors including number of platelets, cellular fragility, or functional environment. PMID:28900369

  14. The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH Plasma tube.

    Science.gov (United States)

    Arslan, Fatma Demet; Karakoyun, Inanc; Basok, Banu Isbilen; Aksit, Merve Zeytinli; Baysoy, Anil; Ozturk, Yasemin Kilic; Guclu, Yusuf Adnan; Duman, Can

    2017-10-15

    Although serum-providing blood tubes with a barrier are still widely used due to their significant advantages, the use of blood tubes with a barrier to provide plasma is becoming widespread. We compared 22 analytes in a BD Vacutainer® Barricor LH Plasma tube for local clinical validation of this new lithium heparin tube with a barrier. Samples from 44 volunteers were collected in different tubes (Becton Dickinson and Company): Z tube without additive (reference), clot-activator tube with gel (SST), lithium heparin tube without gel (LiH), and lithium heparin tube with barrier (Barricor). Analyte concentrations in different tubes were compared with the reference tube. All tubes were also evaluated according to additional testing (different centrifugation durations, blood-sampling techniques and individual differences). Aspartate aminotransferase (AST), glucose (Glc), potassium (K), lactate dehydrogenase (LD), sodium (Na), and total protein (TP) had a significant bias in Barricor (9.19%, - 3.24%, - 4.88%, 21.60%, - 0.40%, 5.03%, respectively) relative to the reference tube. There was no statistical difference between different centrifugation durations and individual differences for AST, K and LD in LiH and/or Barricor (P > 0.05). There was a significant bias for LD between LiH and Barricor in terms of blood-sampling techniques (21.2% and 12.4%, respectively). Recently, the use of plasma has become prominent due to some of its advantages. In this study, plasma AST, K, LD, Glc and TP levels in Barricor were clinically different in comparison to serum. The results of additional tests showed that higher levels of LD in Barricor did not result from haemolysis, and they might be related to other factors including number of platelets, cellular fragility, or functional environment.

  15. Atomic absorption spectrometry using tungsten and molybdenum tubes as metal atomizer

    International Nuclear Information System (INIS)

    Kaneco, Satoshi; Katsumata, Hideyuki; Ohta, Kiyohisa; Suzuki, Tohru

    2007-01-01

    We have developed a metal tube atomizer for the electrothermal atomization atomic absorption spectrometry (ETA-AAS). Tungsten, molybdenum, platinum tube atomizers were used as the metal atomizer for ETA-AAS. The atomization characteristics of various metals using these metal tube atomizers were investigated. The effects of heating rate of atomizer, atomization temperature, pyrolysis temperature, argon purge gas flow rate and hydrogen addition on the atomic absorption signal were investigated for the evaluation of atomization characteristics. Moreover, ETA-AAS with metal tube atomizer has been combined with the slurry-sampling techniques. Ultrasonic slurry-sampling ETA-AAS with metal tube atomizer were effective for the determination of trace metal elements in biological materials, calcium drug samples, herbal medicine samples, vegetable samples and fish samples. Furthermore, a preconcentration method of trace metals involving adsorption on a metal wire has been applied to ETA-AAS with metal tube atomizer. (author)

  16. 32P-postlabeling assay for carcinogen-DNA adducts: description of beta shielding apparatus and semi-automatic spotting and washing devices that facilitate the handling of multiple samples

    International Nuclear Information System (INIS)

    Reddy, M.V.; Blackburn, G.R.

    1990-01-01

    The utilization of the 32 P-postlabeling assay in combination with TLC for the sensitive detection and estimation of aromatic DNA adducts has been increasing. The procedure consists of 32 P-labeling of carcinogen-adducted 3'-nucleotides in the DNA digests using γ- 32 P ATP and polynucleotide kinase, separation of 32 P-labeled adducts by TLC, and their detection by autoradiography. During both 32 P-labeling and initial phases of TLC, a relatively high amount of γ- 32 P ATP is handled when 30 samples are processed simultaneously. We describe the design of acrylic shielding apparatus, semi-automatic TLC spotting devices, and devices for development and washing of multiple TLC plates, which not only provide substantial protection from exposure to 32 P beta radiation, but also allow quick and easy handling of a large number of samples. Specifically, the equipment includes: (i) a multi-tube carousel rack having 15 wells to hold capless Eppendorf tubes and a rotatable lid with an aperture to access individual tubes; (ii) a pipette shielder; (iii) two semi-automatic spotting devices to apply radioactive solutions to TLC plates; (iv) a multi-plate holder for TLC plates; and (v) a mechanical device for washing multiple TLC plates. Item (i) is small enough to be held in one-hand, vortexed, and centrifuged to mix the solutions in each tube while beta radiation is shielded. Items (iii) to (iv) aid in the automation of the assay. (author)

  17. Innovation in pressure tube life assessment

    International Nuclear Information System (INIS)

    Guler, B.; Kalenchuk, D.; Celovsky, A.

    2003-01-01

    The hydrogen equivalent concentration and the rate of hydrogen ingress (in particular, deuterium) in pressure tubes are important parameters that must be assessed to determine the fitness-for-service of CANDU reactors. This paper presents the latest refinement in a process referred to as 'Pressure Tube Sampling', which is the only fully qualified and proven method that allows accurate determination of both the hydrogen equivalent concentration and the rate deuterium ingress without performing an expensive fuel channel removal. Pressure Tube Sampling has evolved over the past fifteen years during which over 2,300 samples have been obtained from CANDU reactors around the globe. In-reactor sampling is the standard method for determining the hydrogen equivalent concentrations and deuterium ingress rates in CANDU reactors. Over the past fifteen years, continual improvements in the Pressure Tube Sampling process have resulted in: the capability to obtain circumferential and axial samples, reduced 'on-face' time, reduced cost, reduced dose to workers, and improved analysis accuracy. Most recently, the new Multi-Head Sampling Tool (MHST) has been developed that continues this trend by using one tool to sample at all four axial pressure tube locations in a single visit to the fuel channel, thereby further improving efficiency. In 2001 October, the MHST was successfully deployed at Wolsong 1 by AECL for Korea Hydro and Nuclear Power. The tool was delivered using their Advanced Delivery Machine (ADM) and a total of sixteen samples were obtained from four channels. A significant saving in time was achieved with a rate of one channel (four samples) being sampled every 2 1/2 hours. For a typical 10-channel campaign, this could equate to a 2 to 3 days time/saving, which is significant in terms of outage schedule, cost, and worker dose. This paper provides a description of some of the latest innovations, with specific details on site application, performance, and end results

  18. Sampling device for radioactive molten salt

    International Nuclear Information System (INIS)

    Shindo, Masato

    1998-01-01

    The present invention provides a device for accurately sampling molten salts to which various kinds of metals in a molten salt storage tank are mixed for analyzing them during a spent fuel dry type reprocessing. Namely, the device comprises a sampling tube having an opened lower end to be inserted into the radioactive molten salts stored in a tank and keeps reduced pressure from the upper end, and a pressure reducing pipeline having one end connected to the sampling tube and other end connected to an evacuating pump. In this device, the top end of the sampling tube is inserted to a position for sampling the radioactive molten salts (molten salts). The pressure inside the evacuating pipeline connected to the upper portion of the sampling tube is reduced for a while. In this case, the inside of the pressure reducing pipeline is previously evacuated by the evacuating pump so as to keep a predetermined pressure. Since the pressure in the sampling tube is lowered, molten salts are inserted into the sampling tube, the sampling tube is withdrawn, and the molten salts flown in the sampling tube are analyzed. (I.S.)

  19. Intercomparison of techniques for inspection and diagnostics of heavy water reactor pressure tubes: Flaw detection and characterization [Phase 1] [Sample summary reports of pressure tube samples from Argentina, India, Canada, Republic of Korea, and Romania

    International Nuclear Information System (INIS)

    2006-05-01

    Research Institute (KAERI), Republic of Korea; - The National Institute for Research and Development for Technical Physics (NIRDTP), Romania; and - Nuclear Non-Destructive Testing Research and Services (NNDT), Romania. This TECDOC reports the results of the collaboration on flaw detection and characterization (Phase 1). A companion publication reports results of the collaboration on characterizing hydride blisters and determining the hydrogen concentration in Zirconium alloys (Phase 2). This CD-ROM contains sample summary reports of pressure tube samples from Argentina, India, Canada, Republic of Korea, and Romania

  20. Small holder farmers coping strategies to household food insecurity ...

    African Journals Online (AJOL)

    This study has aimed at examining the small holder farmers' coping strategies to sustained household food insecurity and hunger in Southern Ethiopia (Sidama Zone). In order to collect the required input data, a comprehensive interview schedule was developed. The data were collected from 614 households who were ...

  1. Small holder farmers coping strategies to household food insecurity ...

    African Journals Online (AJOL)

    Small holder farmers coping strategies to household food insecurity and hunger in Southern Ethiopia. ... Ethiopian Journal of Environmental Studies and Management ... The study further showed that households in the study area employ a range of coping strategies to respond to the high and sustained food insecurity and ...

  2. Development of a dedicated front-end electronics for straw tube trackers in the P-bar ANDA experiment

    International Nuclear Information System (INIS)

    Przyborowski, D.; Fiutowski, T.; Idzik, M.; Swientek, K.; Terlecki, P.; Tokarz, J.; Kajetanowicz, M.; Korcyl, G.; Salabura, P.; Smyrski, J.; Strzempek, P.

    2016-01-01

    The design and tests of front-end electronics for straw tube trackers in the P-bar ANDA experiment at FAIR are presented. The challenges for the front-end electronics, comprising operation at high counting rate up to 1 MHz per straw tube, are discussed and the proposed architecture comprising a switched gain charge sensitive preamplifier (CSP), a pole-zero cancellation circuit (PZC), a second order variable peaking time shaper, a trimming ion tail cancellation circuit, and a baseline holder (BLH), is described. The front-end provides an analogue output and a discriminator with LVDS differential driver for the Time-of-Arrival (ToA) and Time-over-Threshold (ToT) measurements. A prototype readout ASIC featuring four channels was fabricated in 0.35 μm CMOS technology consuming 15.5 mW (analog part) and 12 mW (LVDS) per channel. The results of measurements of peaking time (25–67 ns), gain, noise (ENC 800–2500 el. for various gains), time walk and jitter are presented as well as the first results obtained with prototype straw tubes connected.

  3. Material selection for the tool holder working under hard milling conditions using different multi criteria decision making methods

    International Nuclear Information System (INIS)

    Çalışkan, Halil; Kurşuncu, Bilal; Kurbanoğlu, Cahit; Güven, Şevki Yılmaz

    2013-01-01

    Highlights: ► The material selection problem for tool holders used in hard milling was solved. ► EXPROM2, TOPSIS and VIKOR methods were used for ranking the alternative materials. ► The weighting of criteria was performed by compromised weighting method. ► The best material for the tool holder was selected as Fe–5Cr–Mo–V aircraft steel. -- Abstract: Nowadays machining of materials in their hardened state, also called hard machining, is a challenge in production of tools and molds. It has some advantages such as lower process time and lower manufacturing cost when compared to conventional machining. In machining of hard workpiece materials, however, very high stresses act on the tool holder through the cutting tool. These stresses necessitate the tool holder to have some specific properties. Especially in hard milling, the tool holder should have high stiffness and should be able to dissipate the energy generated during interrupted cutting. Material cost of the tool holder is also important since lower costs provide a competitive advantage for manufacturers. The material selection for the tool holder should be conducted considering aforementioned requirements. To tackle the difficulty of the material selection with specific properties from a large number of alternatives, multi-criteria decision-making (MCDM) methods have been used. In this paper a decision model including extended PROMETHEE II (EXPROM2) (preference ranking organization method for enrichment evaluation), TOPSIS (technique for order performance by similarity to ideal solution) and VIKOR (VIšekriterijumsko KOmpromisno Rangiranje) methods were used for the selection of the best material for the tool holder used in hard milling. The criteria weighting was performed by compromised weighting method composed of AHP (analytic hierarchy process) and Entropy methods. The candidate materials were ranked by using these methods and the results obtained by each method were compared. It was confirmed

  4. Integrating sphere based reflectance measurements for small-area semiconductor samples

    Science.gov (United States)

    Saylan, S.; Howells, C. T.; Dahlem, M. S.

    2018-05-01

    This article describes a method that enables reflectance spectroscopy of small semiconductor samples using an integrating sphere, without the use of additional optical elements. We employed an inexpensive sample holder to measure the reflectance of different samples through 2-, 3-, and 4.5-mm-diameter apertures and applied a mathematical formulation to remove the bias from the measured spectra caused by illumination of the holder. Using the proposed method, the reflectance of samples fabricated using expensive or rare materials and/or low-throughput processes can be measured. It can also be incorporated to infer the internal quantum efficiency of small-area, research-level solar cells. Moreover, small samples that reflect light at large angles and develop scattering may also be measured reliably, by virtue of an integrating sphere insensitive to directionalities.

  5. Long-term stability of glucose: glycolysis inhibitor vs. gel barrier tubes.

    Science.gov (United States)

    Winter, Theresa; Hannemann, Anke; Suchsland, Juliane; Nauck, Matthias; Petersmann, Astrid

    2018-03-12

    Measuring the glucose concentration in whole blood samples is critical due to unsatisfactory glycolysis inhibition. Previous studies showed that Terumo tubes were superior, but they were taken off the European market in 2016 and alternatives were required. This initiated the present evaluation of glucose stability in five available tube types. Venous blood samples were collected from 61 healthy volunteers to test tubes supplied by Terumo (two sets), Greiner FC-Mix, BD FX-Mixture and BD serum. After sampling, the contents were thoroughly mixed and centrifuged within an hour. The glucose concentrations were determined and the samples resuspended except for BD serum tubes (gel barrier). The first 30 samples were stored at room temperature and the remaining 31 at 4°C. After 24, 48, 72 and 96 h, all tubes were (re)centrifuged, and glucose concentration measurements were repeated. Changes in glucose concentrations over time differed significantly between the investigated tube types and to a certain extent between the two storing conditions. Glycolysis was most evident in the BD FX-mixture tubes. Good glucose stability was observed in samples retrieved form BD serum and Greiner tubes. The stability in both Terumo tubes was comparable to that in other studies. Although Greiner and both Terumo tubes are supposed to contain the same glycolysis inhibitor, glucose stability differed between these tubes. We showed that Greiner is an acceptable alternative to Terumo and that glucose in serum that was rapidly separated from corpuscles by a gel barrier is stable for an extended time.

  6. 17 CFR 240.14a-7 - Obligations of registrants to provide a list of, or mail soliciting material to, security holders.

    Science.gov (United States)

    2010-04-01

    ..., form of proxy or other communication to such holders, including to the extent known or reasonably... provided for under applicable state law identifying the proposal or other corporate action that will be the subject of the security holder's solicitation or communication and attesting that: (i) The security holder...

  7. Report on the Installation and Preparedness of a Protochips Fusion in-situ Heating Holder for TEM

    Energy Technology Data Exchange (ETDEWEB)

    Edmondson, Philip D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-03-01

    This brief report documents the procurement and installation of a Protochips Fusion (formerly Aduro) high-temperature, high stability transmission electron microscopy (TEM) specimen holder that allows for the high spatial resolution characterization of material specimens at high temperature in situ of an electron microscope. This specimen holder was specifically procured for use with The FEI Talos F200X Scanning/Transmission Electron Microscope (STEM) in Oak Ridge National Laboratory’s (ORNL’s) Low Activation Materials Development and Analysis (LAMDA) Laboratory. The Protochips Fusion holder will enable high-resolution structural and chemical analysis of irradiated materials at high temperature, becoming a unique capability worldwide, and would encourage high-quality in situ experiments to be conducted on irradiated materials.

  8. Foot-controlled robotic-enabled endoscope holder for endoscopic sinus surgery: A cadaveric feasibility study.

    Science.gov (United States)

    Chan, Jason Y K; Leung, Iris; Navarro-Alarcon, David; Lin, Weiyang; Li, Peng; Lee, Dennis L Y; Liu, Yun-hui; Tong, Michael C F

    2016-03-01

    To evaluate the feasibility of a unique prototype foot-controlled robotic-enabled endoscope holder (FREE) in functional endoscopic sinus surgery. Cadaveric study. Using human cadavers, we investigated the feasibility, advantages, and disadvantages of the robotic endoscope holder in performing endoscopic sinus surgery with two hands in five cadaver heads, mimicking a single nostril three-handed technique. The FREE robot is relatively easy to use. Setup was quick, taking less than 3 minutes from docking the robot at the head of the bed to visualizing the middle meatus. The unit is also relatively small, takes up little space, and currently has four degrees of freedom. The learning curve for using the foot control was short. The use of both hands was not hindered by the presence of the endoscope in the nasal cavity. The tremor filtration also aided in the smooth movement of the endoscope, with minimal collisions. The FREE endoscope holder in an ex-vivo cadaver test corroborated the feasibility of the robotic prototype, which allows for a two-handed approach to surgery equal to a single nostril three-handed technique without the holder that may reduce operating time. Further studies will be needed to evaluate its safety profile and use in other areas of endoscopic surgery. NA. Laryngoscope, 126:566-569, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  9. Proposal of a Budget-Friendly Camera Holder for Endoscopic Ear Surgery.

    Science.gov (United States)

    Ozturan, Orhan; Yenigun, Alper; Aksoy, Fadlullah; Ertas, Burak

    2018-01-01

    Endoscopic ear surgery (EES) is increasingly a preferred technique in otologic society. It offers excellent visualization of the anatomical structures directly and behind the corners with variable angled telescopes. It also provides reduced operative morbidity due to being able to perform surgical interventions with less invasive approaches. Operative preparation and setup time and cost of endoscopy system are less expensive compared with surgical microscopes. On the other hand, the main disadvantage of EES is that the surgery has to be performed with 1 single hand. It is certainly restrictive for an ear surgeon who has been operating with 2 hands under otologic microscopic views for years and certainly requires a learning period and perseverance. Holding the endoscope by a second surgeon is not executable because of insufficient surgical space.Endoscope/camera holders have been developed for those who need the comfort and convenience afforded by double-handed microscopic ear surgery. An ideal endoscope holder should be easy-to-set up, easily controlled, providing a variety of angled views, allowing the surgeon to operate with 2 hands and, budget-friendly. In this article, a commercially available 11-inch magic arm camera holder is proposed by the authors to be used in EES due to its versatile, convenient, and budget-friendly features. It allows 2-handed EES through existing technology and is affordable for surgeons looking for a low-cost and practical solution.

  10. The single chest tube versus double chest tube application after pulmonary lobectomy: A systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Xuefei Zhang

    2016-01-01

    Conclusion: Compared with the double chest tube, the single chest tube significantly decreases amount of drainage, duration of chest tube drainage, pain score, the number of patients who need thoracentesis, and cost. Although there is convincing evidence to confirm the results mentioned herein, they still need to be confirmed by large-sample, multicenter, randomized, controlled trials.

  11. Repositioning accuracy: Comparison of a noninvasive head holder with thermoplastic mask for fractionated radiotherapy and a case report

    International Nuclear Information System (INIS)

    Sweeney, Reinhart; Bale, Reto; Vogele, Michael; Nevinny-Stickel, Meinhart; Bluhm, Anja; Auer, Thomas; Hessenberger, Gerhart; Lukas, Peter

    1998-01-01

    Purpose: To compare accuracy, clinical feasibility, and subjective patient impression between a noninvasive head holder (Vogele Bale Hohner [VBH]; Wellhoefer Dosimetry, Schwarzenbruck, Germany) developed at the University of Innsbruck and the thermoplastic mask fixation system for use in fractionated external radiotherapy. We present a case report of an actual patient fixated in the VBH head holder during radiation therapy. Materials and Methods: The VBH head holder consists of an individualized vacuum dental cast connected to a head plate via two hydraulic arms allowing noninvasive, reproducible head fixation of even uncooperative patients. Accuracy was tested and compared with that of the thermoplastic mask using the Phillips EasyGuide navigation system on five volunteers. Specific external registration points served as landmarks and their positions were compared after each repositioning. System and operator inaccuracy were also taken into account. The times taken for production and repositioning of the respective fixation devices were compared, and subjective impressions were noted. Results: Mean VBH head holder repositioning accuracy was 1.02 mm while that of the thermoplastic mask was 3.05 mm. 69% of mask repositionings showed a deviation > 2 mm and 41% > 3 mm (as opposed to 8% and 1% respectively for the VBH head holder) Those points located farthest away from the respective plane of fixation showed the largest deviations. Both production and repositioning times were similar between the systems; depending upon the patient, the VBH head holder was generally better tolerated than the mask system. Conclusion: Due to its significantly better repositioning accuracy compared to that of the thermoplastic mask, the VBH head holder is especially suited for external radiation requiring precise repositioning due to critical tissues in immediate surrounding of the area to be irradiated

  12. Gastrostomy Tube (G-Tube)

    Science.gov (United States)

    ... any of these problems: a dislodged tube a blocked or clogged tube any signs of infection (including redness, swelling, or warmth at the tube site; discharge that's yellow, green, or foul-smelling; fever) excessive bleeding or drainage from the tube site severe abdominal pain lasting ...

  13. System for Packaging Planetary Samples for Return to Earth

    Science.gov (United States)

    Badescu, Mircea; Bar-Cohen, Yoseph; Backes, paul G.; Sherrit, Stewart; Bao, Xiaoqi; Scott, James S.

    2010-01-01

    A system is proposed for packaging material samples on a remote planet (especially Mars) in sealed sample tubes in preparation for later return to Earth. The sample tubes (Figure 1) would comprise (1) tubes initially having open tops and closed bottoms; (2) small, bellows-like collapsible bodies inside the tubes at their bottoms; and (3) plugs to be eventually used to close the tops of the tubes. The top inner surface of each tube would be coated with solder. The side of each plug, which would fit snugly into a tube, would feature a solder-filled ring groove. The system would include equipment for storing, manipulating, filling, and sealing the tubes. The containerization system (see Figure 2) will be organized in stations and will include: the storage station, the loading station, and the heating station. These stations can be structured in circular or linear pattern to minimize the manipulator complexity, allowing for compact design and mass efficiency. The manipulation of the sample tube between stations is done by a simple manipulator arm. The storage station contains the unloaded sample tubes and the plugs before sealing as well as the sealed sample tubes with samples after loading and sealing. The chambers at the storage station also allow for plug insertion into the sample tube. At the loading station the sample is poured or inserted into the sample tube and then the tube is topped off. At the heating station the plug is heated so the solder ring melts and seals the plug to the sample tube. The process is performed as follows: Each tube is filled or slightly overfilled with sample material and the excess sample material is wiped off the top. Then, the plug is inserted into the top section of the tube packing the sample material against the collapsible bellowslike body allowing the accommodation of the sample volume. The plug and the top of the tube are heated momentarily to melt the solder in order to seal the tube.

  14. Device for radioactivity measurement of liquid samples

    International Nuclear Information System (INIS)

    Lamaziere, J.

    1983-01-01

    The device for low activity gamma measurements comprises an automatic changer for sample transfer from a conveyor to a measuring chamber. The conveyor includes a horizontal table were are regularly distributed sample holders. A lift allows a vertical motion of a plate for the exposition in front of a detector [fr

  15. Multielement analysis of aerosol samples by X-ray fluorescence analysis with totally reflecting sample holders

    International Nuclear Information System (INIS)

    Ketelsen, P.; Knoechel, A.

    1984-01-01

    Aerosole samples on filter support were analyzed using the X-ray flourescence analytical method (Mo excitation) with totally reflecting sample carrier (TXFA). Wet decomposition of the sample material with HNO 3 in an enclosed system and subsequent sample preparation by evaporating an aliquot of the solution on the sample carrier yields detection limits up to 0.3 ng/cm 2 . The reproducibilities of the measurements of the elements K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Rb, Sr, Ba and Pb lie between 5 and 25%. Similar detection limits and reproducibilities are obtained, when low-temperature oxygen plasma is employed for the direct ashing of the homogenously covered filter on the sample carrier. For the systematic loss of elements both methods were investigated with radiotracers as well as with inactive techniques. A comparison of the results with those obtained by NAA, AAS and PIXE shows good agreement in most cases. For the bromine determination and the fast coverage of the main elements a possibility for measuring the filter membrane has been indicated, which neglects the ashing step. The corresponding detection limits are up to 3 ng/cm 2 . (orig.) [de

  16. Sieve-based device for MALDI sample preparation. I. Influence of sample deposition conditions in oligonucleotide analysis to achieve significant increases in both sensitivity and resolution.

    Science.gov (United States)

    Molin, Laura; Cristoni, Simone; Crotti, Sara; Bernardi, Luigi Rossi; Seraglia, Roberta; Traldi, Pietro

    2008-11-01

    Spraying of oligonucleotide-matrix solutions through a stainless steel (ss) sieve (38 microm, 450 mesh) leads to the formation, on the matrix-assisted laser desorption/ionization (MALDI) sample holder, of uniformly distributed microcrystals, well separated from each other. When the resulting sample holder surface is irradiated by laser, abundant molecular species form, with a clear increase in both intensity and resolution with respect to values obtained by 'Dried Droplet', 'Double Layer', and 'Sandwich' deposition methods. In addition, unlike the usual situation, the sample is perfectly homogeneous, and identical spectra are obtained by irradiating different areas. On one hand, the data indicate that this method is highly effective for oligonucleotide MALDI analysis, and on the other, that it can be validly employed for fully automated MALDI procedures.

  17. Modeling returns to education and labour market outcomes of doctoral degree holders in Bulgaria

    OpenAIRE

    Simeonova-Ganeva, Ralitsa; Panayotova, Nataliya; Ganev, Kaloyan

    2013-01-01

    In this study we present the theoretical framework of the so called Mincerian equations used for modelling returns to education. Then, we construct a conceptual framework which allows us to answer the question “What happens to doctoral degree holders in the labour market?”. We analyse data for about 45,000 PhD graduates in Bulgaria from the NSI survey Career development of PhD degree holders run in 2007, 2009, and 2010. An attempt is made to measure pay gaps in terms of gender and major of st...

  18. Ancylostoma caninum: calibration and comparison of diagnostic accuracy of flotation in tube, McMaster and FLOTAC in faecal samples of dogs.

    Science.gov (United States)

    Cringoli, Giuseppe; Rinaldi, Laura; Maurelli, Maria Paola; Morgoglione, Maria Elena; Musella, Vincenzo; Utzinger, Jürg

    2011-05-01

    We performed a calibration of flotation in tube, McMaster and FLOTAC to determine the optimal flotation solution (FS) and the influence of faecal preservation for the diagnosis of Ancylostoma caninum in dogs, and compared the accuracy of the three copromicroscopic techniques. Among nine different FS, sodium chloride and sodium nitrate performed best for detection and quantification of A. caninum eggs. Faecal samples, either fresh or preserved in formalin 5%, resulted in higher A. caninum egg counts, compared to frozen samples or preserved in formalin 10% or sodium acetate-acetic acid-formalin. FLOTAC consistently resulted in higher A. caninum eggs per gram of faeces (EPG) and lower coefficient of variation (CV) than McMaster and flotation in tube. The best results in terms of mean faecal egg counts (highest value, i.e. 117.0EPG) and CV (lowest value, i.e. 4.8%) were obtained with FLOTAC using sodium chloride and faecal samples preserved in formalin 5%. Our findings suggest that the FLOTAC technique should be considered for the diagnosis of A. caninum in dogs. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Micro-PIXE on thin plant tissue samples in frozen hydrated state: A novel addition to JSI nuclear microprobe

    International Nuclear Information System (INIS)

    Vavpetič, P.; Pelicon, P.; Vogel-Mikuš, K.; Grlj, N.; Pongrac, P.; Jeromel, L.; Ogrinc, N.; Regvar, M.

    2013-01-01

    Recently we completed a construction of a cryostat at Jožef Stefan Institute (JSI) nuclear microprobe enabling us to analyze various types of biological samples in frozen hydrated state using micro-PIXE/STIM/RBS. Sample load-lock system was added to our existing setup to enable us to quickly insert a sample holder with frozen hydrated tissue samples onto a cold goniometer head cooled with liquid nitrogen inside the measuring chamber. Cryotome-cut slices of frozen hydrated plant samples were mounted between two thin silicon nitride foils and then attached to the sample holder. Sufficient thermal contact between silicon nitride foils and sample holder must be achieved, as well as between the sample holder and the cold goniometer head inside the measuring chamber to prevent melting of the samples. Matrix composition of frozen hydrated tissue is consisted mostly of ice. Thinning of the sample as well as water evaporation during high vacuum and proton beam exposure was inspected by the measurements with RBS and STIM method simultaneously with micro-PIXE. For first measuring attempts a standard micro-PIXE configuration for tissue mapping was used with proton beam cross section of 1.2 × 1.2 μm 2 and a beam current of 100 pA. The temperature of the cold goniometer head was kept below 130 K throughout the entire proton beam exposure. First measurements of thin plant tissue samples in frozen hydrated state show minute sample degradation during the 10 h period of micro-PIXE measurements

  20. The Tube on YouTube: TV Series, Media Strategies, and User Tactics in a Transmedia Environment

    OpenAIRE

    Rodríguez Ferrándiz, Raúl; Tur-Viñes, Victoria; Mora Contreras, Francisco Javier

    2015-01-01

    This study analyzes the traffic generated on YouTube around television series. We selected a sample of 314 short YouTube videos about 21 Spanish TV series that premiered in 2013 by Spain’s three most popular mainstream television networks (Telecinco, Antena 3, and La1). These videos, which together received more than 24 million views, were classified according to two key variables: the nature (official or nonofficial) of the YouTube channel on which they were located and the exclusivity of th...

  1. A Study on consensus development through stake holder engagement for the use of nuclear energy in Japan

    International Nuclear Information System (INIS)

    Aoyama, Yoshiko; Sawada, Tetsuo; Fujii, Yasuhiko

    2008-01-01

    In order to alleviate the distrust surrounding the use of nuclear energy and operation of nuclear facilities, as well as to foster trust and find better ways to live in harmony with society, it is essential for the state and electric power utilities not to provide one-sided information, but to formulate adequate bilateral communication and dialogue with stake holders. In this study, we conducted a case study focused on four stake holder meetings with a view to ensuring safety in the use of nuclear energy and operation of nuclear facilities in Japan; the 'Community Meeting for Securing the Transparency of Kashiwazaki-Kariwa Nuclear Power Station (Chiiki-no-kai)'; the 'Monitoring and Evaluation Conference on Environmental Radiation', established by communities where nuclear facilities are installed; the 'Round-Table Conference on Nuclear Power Policy' and the 'Conference for Public Participation and Decision Making for Nuclear Energy Policy' organized by Japan Atomic Energy Commission. As a consequence, it has been observed that in each case varying opinions were summarized through stake holder meetings, but the fact that no system exists to reflect these opinions in design of the nuclear energy policy has emerged as a controversial point. This study suggests future efforts in regard to the requirements in Japan for stake holder meetings that are necessary for fostering trust and mutual understanding among stake holders including the state and local government, electric power utilities and local residents. (author)

  2. 15N tracer technique for studying efficiency of deep placed fertilizer through nutriseed holder in direct seeded rice

    International Nuclear Information System (INIS)

    Asha, V.S.; Arulmozhiselvan, K.

    2006-01-01

    In order to estimate N use efficiency in deep placement of NPK straight fertilizers, two pot experiments were conducted in high clay soil with direct seeded rice. 15 N urea was used as a tracer. A newly designed 'Nutriseed Holder' was used for simultaneous deep placement of fertilizers and sowing of seeds. Each holder had two cavities, one on top for holding seed and another one at bottom for holding fertilizer material. By implanting a holder in puddled soil, a rice hill was established. The length (5 or 10 cm) and width (8 or 12 mm) of nutriseed holder was standardized while evaluating the effect of Azolla, neem and seed inoculants. Appreciably, deep placement of plain NPK fertilizer in 12 mm holder placed at 5 cm depth recorded the highest grain yield with a yield increase of 81.8 per cent during rabi 2002 (cv CO 43) and 84.8 per cent during summer 2003 (cv CO 47) over broadcast application. Further, it increased recovery of added JSN in grain + straw to the tune of 57.1 per cent in rabi and 54.7 per cent in summer as compared to broadcast application (26.1% in rabi, 34.2 in summer). Deep placement enhanced more retention in soil (up to 9.0% in rabi, 14.6% in summer) whereas broadcast application enhanced more retention in Azolla biomass that was grown in floodwater (up to 2.3 % in rabi, 4.3 % in summer). Use of 12 mm width nutriseed holder aiding deep placement at 5 cm depth was found suitable for deriving high yield and N use efficiency. (author)

  3. Visual accumulation tube for size analysis of sands

    Science.gov (United States)

    Colby, B.C.; Christensen, R.P.

    1956-01-01

    The visual-accumulation-tube method was developed primarily for making size analyses of the sand fractions of suspended-sediment and bed-material samples. Because the fundamental property governing the motion of a sediment particle in a fluid is believed to be its fall velocity. the analysis is designed to determine the fall-velocity-frequency distribution of the individual particles of the sample. The analysis is based on a stratified sedimentation system in which the sample is introduced at the top of a transparent settling tube containing distilled water. The procedure involves the direct visual tracing of the height of sediment accumulation in a contracted section at the bottom of the tube. A pen records the height on a moving chart. The method is simple and fast, provides a continuous and permanent record, gives highly reproducible results, and accurately determines the fall-velocity characteristics of the sample. The apparatus, procedure, results, and accuracy of the visual-accumulation-tube method for determining the sedimentation-size distribution of sands are presented in this paper.

  4. Development of an automatic sample changer and a data acquisition system

    International Nuclear Information System (INIS)

    Bianchini, Ricardo M.; Estevez, Jorge; Vollmer, Alberto E.; Iglicki, Flora A.

    1999-01-01

    An automatic electro-pneumatic sample changer with a rotating sample holder is described. The changer is coupled through an electronic interface with the data acquisition station. The software to automate the system has been designed. (author)

  5. The effect of simulated flash heating pasteurisation and Holder pasteurisation on human milk oligosaccharides.

    Science.gov (United States)

    Daniels, Brodie; Coutsoudis, Anna; Autran, Chloe; Amundson Mansen, Kimberly; Israel-Ballard, Kiersten; Bode, Lars

    2017-08-01

    Human milk oligosaccharides (HMOs) have important protective functions in human milk. A low-cost remote pasteurisation temperature-monitoring system has been designed using FoneAstra, a cell phone-based networked sensing system to monitor simulated flash heat pasteurisation. To compare the pasteurisation effect on HMOs of the FoneAstra FH method with the current Sterifeed Holder method used by human milk banks. Donor human milk samples (n = 48) were obtained from a human milk bank and pasteurised using the two pasteurisation methods. HMOs were purified from samples and labelled before separation using high-performance liquid chromatography. Concentrations of total HMOs, sialylated and fucosylated HMOs and individual HMOs using the two pasteurisation methods were compared using repeated-measures ANOVA. The study demonstrated no difference in total concentration of HMOs between the two pasteurisation methods and a small but significant increase in the total concentration of HMOs regardless of pasteurisation methods compared with controls (unpasteurised samples) (pmilk and therefore is a possible alternative for providing safely sterilised human milk for low- and middle-income countries.

  6. Design and burn-up analyses of new type holder for silicon neutron transmutation doping.

    Science.gov (United States)

    Komeda, Masao; Arai, Masaji; Tamai, Kazuo; Kawasaki, Kozo

    2016-07-01

    We have developed a new silicon irradiation holder with a neutron filter to increase the irradiation efficiency. The neutron filter is made of an alloy of aluminum and B4C particles. We fabricated a new holder based on the results of design analyses. This filter has limited use in applications requiring prolonged use due to a decrease in the amount of (10)B in B4C particles. We investigated the influence of (10)B reduction on doping distribution in a silicon ingot by using the Monte Carlo Code MVP. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Trace Analysis in End-Exhaled Air Using Direct Solvent Extraction in Gas Sampling Tubes: Tetrachloroethene in Workers as an Example

    Directory of Open Access Journals (Sweden)

    Chris-Elmo Ziener

    2014-01-01

    Full Text Available Simple and cost-effective analytical methods are required to overcome the barriers preventing the use of exhaled air in routine occupational biological monitoring. Against this background, a new method is proposed that simplifies the automation and calibration of the analytical measurements. End-exhaled air is sampled using valveless gas sampling tubes made of glass. Gaseous analytes are transferred to a liquid phase using a microscale solvent extraction performed directly inside the gas sampling tubes. The liquid extracts are analysed using a gas chromatograph equipped, as usual, with a liquid autosampler, and liquid standards are used for calibration. For demonstration purposes, the method’s concept was applied to the determination of tetrachloroethene in end-exhaled air, which is a biomarker for occupational tetrachloroethene exposure. The method’s performance was investigated in the concentration range 2 to 20 μg tetrachloroethene/L, which corresponds to today’s exposure levels. The calibration curve was linear, and the intra-assay repeatability and recovery rate were sufficient. Analysis of real samples from dry-cleaning workers occupationally exposed to tetrachloroethene and from nonexposed subjects demonstrated the method’s utility. In the case of tetrachloroethene, the method can be deployed quickly, requires no previous experiences in gas analysis, provides sufficient analytical reliability, and addresses typical end-exhaled air concentrations from exposed workers.

  8. Contrastive Analysis and Research on Negative Pressure Beam Tube System and Positive Pressure Beam Tube System for Mine Use

    Science.gov (United States)

    Wang, Xinyi; Shen, Jialong; Liu, Xinbo

    2018-01-01

    Against the technical defects of universally applicable beam tube monitoring system at present, such as air suction in the beam tube, line clogging, long sampling time, etc., the paper analyzes the current situation of the spontaneous combustion fire disaster forecast of mine in our country and these defects one by one. On this basis, the paper proposes a research thought that improving the positive pressure beam tube so as to substitute the negative pressure beam tube. Then, the paper introduces the beam tube monitoring system based on positive pressure technology through theoretical analysis and experiment. In the comparison with negative pressure beam tube, the paper concludes the advantage of the new system and draws the conclusion that the positive pressure beam tube is superior to the negative pressure beam tube system both in test result and test time. At last, the paper proposes prospect of the beam tube monitoring system based on positive pressure technology.

  9. Improved circulating microparticle analysis in acid-citrate dextrose (ACD) anticoagulant tube.

    Science.gov (United States)

    György, Bence; Pálóczi, Krisztina; Kovács, Alexandra; Barabás, Eszter; Bekő, Gabriella; Várnai, Katalin; Pállinger, Éva; Szabó-Taylor, Katalin; Szabó, Tamás G; Kiss, Attila A; Falus, András; Buzás, Edit I

    2014-02-01

    Recently extracellular vesicles (exosomes, microparticles also referred to as microvesicles and apoptotic bodies) have attracted substantial interest as potential biomarkers and therapeutic vehicles. However, analysis of microparticles in biological fluids is confounded by many factors such as the activation of cells in the blood collection tube that leads to in vitro vesiculation. In this study we aimed at identifying an anticoagulant that prevents in vitro vesiculation in blood plasma samples. We compared the levels of platelet microparticles and non-platelet-derived microparticles in platelet-free plasma samples of healthy donors. Platelet-free plasma samples were isolated using different anticoagulant tubes, and were analyzed by flow cytometry and Zymuphen assay. The extent of in vitro vesiculation was compared in citrate and acid-citrate-dextrose (ACD) tubes. Agitation and storage of blood samples at 37 °C for 1 hour induced a strong release of both platelet microparticles and non-platelet-derived microparticles. Strikingly, in vitro vesiculation related to blood sample handling and storage was prevented in samples in ACD tubes. Importantly, microparticle levels elevated in vivo remained detectable in ACD tubes. We propose the general use of the ACD tube instead of other conventional anticoagulant tubes for the assessment of plasma microparticles since it gives a more realistic picture of the in vivo levels of circulating microparticles and does not interfere with downstream protein or RNA analyses. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Colour coding for blood collection tube closures - a call for harmonisation.

    Science.gov (United States)

    Simundic, Ana-Maria; Cornes, Michael P; Grankvist, Kjell; Lippi, Giuseppe; Nybo, Mads; Ceriotti, Ferruccio; Theodorsson, Elvar; Panteghini, Mauro

    2015-02-01

    At least one in 10 patients experience adverse events while receiving hospital care. Many of the errors are related to laboratory diagnostics. Efforts to reduce laboratory errors over recent decades have primarily focused on the measurement process while pre- and post-analytical errors including errors in sampling, reporting and decision-making have received much less attention. Proper sampling and additives to the samples are essential. Tubes and additives are identified not only in writing on the tubes but also by the colour of the tube closures. Unfortunately these colours have not been standardised, running the risk of error when tubes from one manufacturer are replaced by the tubes from another manufacturer that use different colour coding. EFLM therefore supports the worldwide harmonisation of the colour coding for blood collection tube closures and labels in order to reduce the risk of pre-analytical errors and improve the patient safety.

  11. An investigation on SA 213-Tube to SA 387-Tube plate using friction welding process

    Energy Technology Data Exchange (ETDEWEB)

    Rajan, S. Pandia; Kumaraswamidhas, L. A. [Indian Institute of Technology, Jharkhand (India); Kumaran, S. Senthil [RVS School of Engineering and Technology, Tamil Nadu (India); Muthukumaran, S. [National Institute of Technology, Tamil Nadu (India)

    2016-01-15

    Friction welding of tube to tube plate using an external tool (FWTPET) is a relatively newer solid state welding process used for joining tube to tube plate of either similar or dissimilar materials with enhanced mechanical and metallurgical properties. In the present study, FWTPET has been used to weld SA 213 (Grade T12) tube with SA 387 (Grade 22) tube plate. The welded samples are found to have satisfactory joint strength and the Energy dispersive X-ray analysis (EDX), X-ray diffraction (XRD) study showed that inter metallic compound is absent in the weld zone. The different weld joints have been identified and the phase composition is found using EDX and XRD. Microstructures have been analyzed using optical and Scanning electron microscopy (SEM). The mechanical properties such as hardness, compressive shear strength and peel test for different weld conditions are studied and the hardness survey revealed that there is increase in hardness at the weld interface due to grain refinement. The corrosion behavior for different weld conditions have been analyzed and the weld zone is found to have better corrosion resistance due to the influence of the grain refinement after FWTPET welding process. Hence, the present investigation is carried out to study the behavior of friction welded dissimilar joints of SA 213 tube and SA 387 tube plate joints and the results are presented. The present study confirms that a high quality tube to tube plate joint can be achieved using FWTPET process at 1120 rpm.

  12. Assessing the authority of political office-holders : The leadership capital index

    NARCIS (Netherlands)

    Bennister, Mark; t Hart, Paul; Worthy, Benjamin

    2015-01-01

    This article argues that the extent to which political office-holders can effectively attain and wield authority is a function of the stock of ‘leadership capital’. Drawing on the concept of political capital, the article defines leadership capital as aggregate authority composed of three

  13. Microstructural examination of irradiated zircaloy-2 pressure tube material

    International Nuclear Information System (INIS)

    Srivastava, D.; Tewari, R.; Dey, G.K.; Sah, D.N.; Banerjee, S.

    2005-01-01

    Irradiation induced microstructural changes in Zr alloys strongly influence the creep, growth and mechanical properties of pressure tube material. Since dimensional changes and mechanical property degradation can limit the life of pressure tube, it is essential to study and develop an understanding of the microstructure produced by neutron irradiation, by examining samples taken from the irradiated components. In the present work, an effort has been made to examine, microstructure of the Zircaloy-2 pressure tube material irradiated in the Indian Pressurized Heavy Water Reactor (PHWR). The present work is a first step towards a comprehensive program of characterization of microstructure of reactor materials after irradiation to different fluence levels in power reactors. In this study, samples from a Zircaloy-2 pressure tube, which had been in operation in the high flux region of Rajasthan Atomic Power Station Unit 1, for a period for 6.77 effective full power years (EFPYs), have been prepared and examined. The samples selected from the tube are expected to have a cumulative radiation damage of about 3 dpa. Samples prepared from the off cuts of RAPS-1 pressure tubes were also studied for examining the unirradiated microstructure of the material. The samples were examined in a 200kV JEOL 2000 FX microscope. This paper presents the distinct features observed in irradiated sample and a comprehensive comparison of the microstructures of the unirradiated and irradiated material. The effect of annealing on the annihilation of the defects generated during irradiation has been also studied. The bright field micrographs revealed that microstructure of the irradiated samples was different in many respects from the microstructure of the unirradiated samples. The presence of defect structure in the form of loops etc could be seen in the irradiated sample. These loops were mostly c-type loops lying in the basal plane. The dissolution and redistribution of the precipitates were

  14. Standard Procedure for Dose Assessment using the film holder NRPB/AERE and the film AGFA Monitoring 2/10

    International Nuclear Information System (INIS)

    Guillen, J.A.

    1998-07-01

    This paper describes the calculation method to assess dose and energy using the film holder from NRPB/AERE and the film Agfa Monitoring 2/10. Also includes all the steps since preparing the standard curve, fitting of calibration curve, dose assesment, description of filtration of the film holder and the form of the calibration curve

  15. Update of NIST half-life results corrected for ionization chamber source-holder instability

    International Nuclear Information System (INIS)

    Unterweger, M.P.; Fitzgerald, R.

    2014-01-01

    As reported at the ICRM 2011, it was discovered that the source holder used for calibrations in the NIST 4πγ ionization chamber (IC) was not stable. This has affected a large number of half-life measurement results previously reported and used in compilations of nuclear data. Corrections have been made on all of the half-life data based on the assumption that the changes to the ionization chamber response were gradual. The corrections are energy dependent and therefore radionuclide specific. This presentation will review our results and present the recommended changes in half-life values and/or uncertainties. - Highlights: • The NIST half-life data is corrected for sample positioning variations and refitted. • These results are reported and increased errors in the reported values are given. • Longer lived radionuclides are discussed

  16. X-ray diffraction without sample preparation: Proof-of-principle experiments

    International Nuclear Information System (INIS)

    Hansford, Graeme M.

    2013-01-01

    The properties of a novel X-ray diffraction (XRD) technique having very low sensitivity to the sample morphology were previously elucidated through theoretical considerations and model simulations (Hansford, 2011). This technique opens up the possibility of mineralogical analysis by XRD without sample preparation. Here, the results of proof-of-principle experimental tests are presented. Two sets of experiments were performed using a vacuum chamber equipped with an X-ray tube source, sample holder and charge-coupled detector. Firstly, a pressed-powder pellet of α-quartz was placed in three different positions relative to the X-ray source and detector. The changes in position represent gross sample movements which would be inconceivable in conventional XRD analysis. The resulting back-reflection energy-dispersive spectra show a very high degree of correspondence other than an overall intensity factor dependent on the distance between the sample and detector. Secondly, the back-reflection spectrum of an unprepared limestone hand specimen, having mm-scale surface morphology, was compared to the spectrum of a calcite pressed-powder pellet. The correspondence of the diffraction peaks in the spectra demonstrate that the limestone is comprised dominantly of calcite. In both cases, the claims of the earlier paper are fully supported by the results of these experimental tests. -- Highlights: • Proof-of-principle tests of a novel X-ray diffraction (XRD) method were conducted. • Very low sensitivity to sample position and orientation was demonstrated. • Insensitivity to sample morphology is inferred. • A simple analysis of an unprepared limestone hand specimen was performed. • This technique enables mineralogical analysis by XRD without sample preparation

  17. Packed in-tube solid phase microextraction with graphene oxide supported on aminopropyl silica: Determination of target triazines in water samples.

    Science.gov (United States)

    De Toffoli, Ana L; Fumes, Bruno H; Lanças, Fernando M

    2018-02-22

    On-line in-tube solid phase microextraction (in-tube SPME) coupled to high performance liquid chromatography and tandem mass spectrometry (HPLC-MS/MS) was successfully applied to the determination of selected triazines in water samples. The method based on the employment of a packed column containing graphene oxide (GO) supported on aminopropyl silica (Si) showed that the extraction phase has a high potential for triazines extraction aiming to its physical-chemical properties including ultrahigh specific surface area, good mechanical and thermal stability and high fracture strength. Injection volume and loading time were both investigated and optimized. The method validation using Si-GO to extract and concentrate the analytes showed satisfactory results, good sensitivity, good linearity (0.2-4.0 µg L -1 ) and low detection limits (1.1-2.9 ng L -1 ). The high extraction efficiency was determined with enrichment factors ranging from 1.2-2.9 for the lowest level, 1.3-4.9 intermediate level and 1.2-3.0 highest level (n = 3). Although the analytes were not detected in the real samples evaluated, the method has demonstrated to be efficient through its application in the analysis of spiked triazines in ground and mineral water samples.

  18. Sample summary report for KOR1 pressure tube sample

    International Nuclear Information System (INIS)

    Lee, Hee Jong; Nam, Min Woo; Choi, Young Ha

    2006-01-01

    This summary report includes basically the following: - The FLAW CHARACTERIZATION TABLE of KOR1 sample and supporting documentation. - The CROSS REFERENCE TABLES for each investigator, which is the SAMPLE INSPECTION TABLE that cross reference to the FLAW CHARACTERIZATION TABLE. - Each Sample Inspection Report as Appendices

  19. Etching of Niobium Sample Placed on Superconducting Radio Frequency Cavity Surface in Ar/CL2 Plasma

    International Nuclear Information System (INIS)

    Upadhyay, Janardan; Phillips, Larry; Valente, Anne-Marie

    2011-01-01

    Plasma based surface modification is a promising alternative to wet etching of superconducting radio frequency (SRF) cavities. It has been proven with flat samples that the bulk Niobium (Nb) removal rate and the surface roughness after the plasma etchings are equal to or better than wet etching processes. To optimize the plasma parameters, we are using a single cell cavity with 20 sample holders symmetrically distributed over the cell. These holders serve the purpose of diagnostic ports for the measurement of the plasma parameters and for the holding of the Nb sample to be etched. The plasma properties at RF (100 MHz) and MW (2.45 GHz) frequencies are being measured with the help of electrical and optical probes at different pressures and RF power levels inside of this cavity. The niobium coupons placed on several holders around the cell are being etched simultaneously. The etching results will be presented at this conference.

  20. Etching of Niobium Sample Placed on Superconducting Radio Frequency Cavity Surface in Ar/CL2 Plasma

    Energy Technology Data Exchange (ETDEWEB)

    Janardan Upadhyay, Larry Phillips, Anne-Marie Valente

    2011-09-01

    Plasma based surface modification is a promising alternative to wet etching of superconducting radio frequency (SRF) cavities. It has been proven with flat samples that the bulk Niobium (Nb) removal rate and the surface roughness after the plasma etchings are equal to or better than wet etching processes. To optimize the plasma parameters, we are using a single cell cavity with 20 sample holders symmetrically distributed over the cell. These holders serve the purpose of diagnostic ports for the measurement of the plasma parameters and for the holding of the Nb sample to be etched. The plasma properties at RF (100 MHz) and MW (2.45 GHz) frequencies are being measured with the help of electrical and optical probes at different pressures and RF power levels inside of this cavity. The niobium coupons placed on several holders around the cell are being etched simultaneously. The etching results will be presented at this conference.

  1. Increasing the Deep Drawability of Al-1050 Aluminum Sheet using Multi-Point Blank Holder

    Directory of Open Access Journals (Sweden)

    Gavas, M.

    2006-01-01

    Full Text Available Aluminum alloys have been widely used in the fields of automobile and aerospace industries. Due to their bad cold-formability in deep drawing, a lot of forming methods have been implemented to increase the drawing height and the limiting drawing rate (LDR. The conventional deep drawing process is limited to a certain limit drawing ratio beyond which failure will ensue. The purpose of this experimental study is to examine the possibilities of increasing this limitation using the multi-point blank holder. The results from the experiments showed that the multi-point blank holder is effective way to promote deep drawability of Al-1050 sheet.

  2. Patient identification and tube labelling

    DEFF Research Database (Denmark)

    van Dongen-Lases, Edmée C; Cornes, Michael P; Grankvist, Kjell

    2016-01-01

    of phlebotomy procedures with the CLSI H3-A6 guideline was unacceptably low, and that patient identification and tube labelling are amongst the most critical steps in need of immediate attention and improvement. The process of patient identification and tube labelling is an essential safety barrier to prevent...... patient identity mix-up. Therefore, the EFLM Working Group aims to encourage and support worldwide harmonisation of patient identification and tube labelling procedures in order to reduce the risk of preanalytical errors and improve patient safety. With this Position paper we wish to raise awareness...... and provide recommendations for proper patient and sample identification procedures....

  3. Applications of liquid scintillation tubes

    International Nuclear Information System (INIS)

    Broga, D.W.

    1977-01-01

    A new cocktail containing device for liquid scintillation counting, the scintillation tube, consists of a two-layered plastic bag which is heatsealed after the cocktail and sample have been placed in it. It is then placed in a carrying vial and counted in a conventional liquid scintillation counter. These tubes have proved to be a practical and economical alternative to vials. Some of their advantages are elimination of absorption problems, transparency, lower background and higher counting efficiency, low breakage danger and savings in waste disposal costs. Two applications for which the tubes are particularly suitable are the counting of laboratory swipes and urine analysis. (author)

  4. Definition of the dose(tempo)-distribution in the biological irradiation-facility of the RIVM

    International Nuclear Information System (INIS)

    Bader, F.J.M.

    1990-02-01

    The RIVM biological irradiation facility (BBF) for the irradiation of biological samples and small animals is a self shielded device and can be safely operated in an existing laboratory environment. There are two 137 Cs sources (15TBq) in a bilateral geometry to give maximum dose uniformity. The easily accessible irradiation chamber is housed in a rotating lead shielding. The dosimetry of BBF was performed by the Dosimetry Section of the RIVM. Experiments were made to determine the absorbed dose in plastic tubes filled with water and the dose distribution over the tube-holder. Separate experiments were made to determine the absorbed dose during the rotation of the irradiation chamber and to check the irradiation timer. For the experiments LiF:Mg,Ti (TLD-100) extruded ribbons were used. The TLDs were calibrated in a collimated beam of 137 Cs gamma rays. The determination of the absorbed dose in water was based on a users biological irradiation set up. The TLDs were individually sealed in thin plastic foil and put in plastic tubes filled for 1/3 with water. The tubes were vertically placed in the tube-holder and placed in the centre of the irradiation chamber. The results show that the absorbed dose in water (determined on January 1, 1990) is equal to 0.97 Gy/timer-unit, with a total uncertainty of 7 percent (1σ). During the rotation of the irradiation chamber the absorbed dose (determined on January 1, 1990) is equal to 0.38 Gy, with a total uncertainty of 15 percent (1σ). The variation of the dose distribution was determined at 15 different measurement points distributed over the tube-holder. The dosis in the measurement point in the centre of the tube-holder was taken as reference value. The maximum observed deviation over the other 14 measurement points amounts to -16 percent of it. The BBF-timer was checked against a special timer. The results indicate that within a range from 2-11 'timer-units' no differences are present. (author). 6 refs.; 6 figs.; 3 fotos

  5. Precision tool holder with flexure-adjustable, three degrees of freedom for a four-axis lathe

    Science.gov (United States)

    Bono, Matthew J [Pleasanton, CA; Hibbard, Robin L [Livermore, CA

    2008-03-04

    A precision tool holder for precisely positioning a single point cutting tool on 4-axis lathe, such that the center of the radius of the tool nose is aligned with the B-axis of the machine tool, so as to facilitate the machining of precision meso-scale components with complex three-dimensional shapes with sub-.mu.m accuracy on a four-axis lathe. The device is designed to fit on a commercial diamond turning machine and can adjust the cutting tool position in three orthogonal directions with sub-micrometer resolution. In particular, the tool holder adjusts the tool position using three flexure-based mechanisms, with two flexure mechanisms adjusting the lateral position of the tool to align the tool with the B-axis, and a third flexure mechanism adjusting the height of the tool. Preferably, the flexures are driven by manual micrometer adjusters. In this manner, this tool holder simplifies the process of setting a tool with sub-.mu.m accuracy, to substantially reduce the time required to set the tool.

  6. An MR/MRI compatible core holder with the RF probe immersed in the confining fluid

    Science.gov (United States)

    Shakerian, M.; Balcom, B. J.

    2018-01-01

    An open frame RF probe for high pressure and high temperature MR/MRI measurements was designed, fabricated, and tested. The open frame RF probe was installed inside an MR/MRI compatible metallic core holder, withstanding a maximum pressure and temperature of 5000 psi and 80 °C. The open frame RF probe was tunable for both 1H and 19F resonance frequencies with a 0.2 T static magnetic field. The open frame structure was based on simple pillars of PEEK polymer upon which the RF probe was wound. The RF probe was immersed in the high pressure confining fluid during operation. The open frame structure simplified fabrication of the RF probe and significantly reduced the amount of polymeric materials in the core holder. This minimized the MR background signal detected. Phase encoding MRI methods were employed to map the spin density of a sulfur hexafluoride gas saturating a Berea core plug in the core holder. The SF6 was imaged as a high pressure gas and as a supercritical fluid.

  7. Inactivation of high-risk human papillomaviruses by Holder pasteurization: implications for donor human milk banking.

    Science.gov (United States)

    Donalisio, Manuela; Cagno, Valeria; Vallino, Marta; Moro, Guido E; Arslanoglu, Sertac; Tonetto, Paola; Bertino, Enrico; Lembo, David

    2014-01-01

    Several studies have recently reported the detection of oncogenic human papillomaviruses (HPV) in human milk of a minority of lactating mothers. These findings raised safety concerns in the context of human donor milk banking given the potential risk of HPV transmission to recipient infants. The aim of this study was to investigate whether the Holder pasteurization, a procedure currently in use in human donor milk banks for milk pasteurization, completely inactivates high-risk and low-risk HPV. HPV pseudoviruses (PsV) were generated, spiked into cell culture medium or donor human milk and subjected to thermal inactivation. HPV PsV infectivity and morphological integrity was analyzed by cell-based assay and by electron microscopy, respectively. The Holder pasteurization completely inactivated the infectivity of high-risk (types 16 and 18) and low-risk (type 6) HPV both in cell culture medium and in human milk causing PsV particle disassembly. The results presented here indicate that the Holder pasteurization is an efficient procedure to inactivate high-risk and low-risk HPV thus preventing the potential risk of their transmission through human donor milk.

  8. Smart Farming: Including Rights Holders for Responsible Agricultural Innovation

    OpenAIRE

    Kelly Bronson

    2018-01-01

    This article draws on the literature of responsible innovation to suggest concrete processes for including rights holders in the “smart” agricultural revolution. It first draws upon historical agricultural research in Canada to highlight how productivist values drove seed innovations with particular consequences for the distribution of power in the food system. Next, the article uses document analysis to suggest that a similar value framework is motivating public investment in smart farming i...

  9. A combinatory approach for analysis of protein sets in barley sieve-tube samples using EDTA-facilitated exudation and aphid stylectomy.

    Science.gov (United States)

    Gaupels, Frank; Knauer, Torsten; van Bel, Aart J E

    2008-01-01

    This study investigated advantages and drawbacks of two sieve-tube sap sampling methods for comparison of phloem proteins in powdery mildew-infested vs. non-infested Hordeum vulgare plants. In one approach, sieve tube sap was collected by stylectomy. Aphid stylets were cut and immediately covered with silicon oil to prevent any contamination or modification of exudates. In this way, a maximum of 1muL pure phloem sap could be obtained per hour. Interestingly, after pathogen infection exudation from microcauterized stylets was reduced to less than 40% of control plants, suggesting that powdery mildew induced sieve tube-occlusion mechanisms. In contrast to the laborious stylectomy, facilitated exudation using EDTA to prevent calcium-mediated callose formation is quick and easy with a large volume yield. After two-dimensional (2D) electrophoresis, a digital overlay of the protein sets extracted from EDTA solutions and stylet exudates showed that some major spots were the same with both sampling techniques. However, EDTA exudates also contained large amounts of contaminative proteins of unknown origin. A combinatory approach may be most favourable for studies in which the protein composition of phloem sap is compared between control and pathogen-infected plants. Facilitated exudation may be applied for subtractive identification of differentially expressed proteins by 2D/mass spectrometry, which requires large amounts of protein. A reference gel loaded with pure phloem sap from stylectomy may be useful for confirmation of phloem origin of candidate spots by digital overlay. The method provides a novel opportunity to study differential expression of phloem proteins in monocotyledonous plant species.

  10. 17 CFR 270.32a-2 - Exemption for initial period from vote of security holders on independent public accountant for...

    Science.gov (United States)

    2010-04-01

    ... from vote of security holders on independent public accountant for certain registered separate accounts... from vote of security holders on independent public accountant for certain registered separate accounts... 32(a) of the Act that selection of an independent public accountant shall have been submitted for...

  11. Assessment of conditions of the spent nuclear fuel stored in the stainless steel channel-holders

    International Nuclear Information System (INIS)

    Pesic, M.; Sotic, O.; Cupac, S.; Maksin, T.; Dasic, N.

    2003-01-01

    The IAEA technical co-operation project 'Safe Removal of Spent Fuel of the Vinca RA Research Reactor' is carried out at the Vinca Institute of Nuclear Sciences, Belgrade, Serbia and Montenegro, since January 2003. Present activities will provide up-to-date information on the conditions of the spent nuclear fuel, stored in the stainless steel channel-holders ('chekhols') and on the water quality in the storage basins. Water samples taken out from the chekhols and the basins are measured to determine their activity and chemical parameters. Until September 2003, about 1/3 of the chekhols containing spent fuel elements with initial enrichment of 2% and 80% of uranium were inspected. High activity of Cs-137 was found in several water samples taken out from chekhols. All water samples show very high electrical conductivity, while those taken from the basins show the presence of chlorides and aluminium ions, too. Information on established procedures and measuring results are given in this paper. The obtained results, so far, show that the spent nuclear fuel elements are leaking in about 10% of chekhols. (author)

  12. Development and installation of an automatic sample changer for neutron activation analysis

    International Nuclear Information System (INIS)

    Domienikan, Claudio; Lapolli, Andre L.; Schoueri, Roberto M.; Moreira, Edson G.; Vasconcellos, Marina B.A.

    2013-01-01

    A Programmable and Automatic Sample Changer was built and installed at the Neutron Activation Analysis Laboratory of the Nuclear and Energy Research Institute - IPEN-CNEN/SP, Brazil. This Automatic Sample Changer allows the fully automated measurement of up to 25 samples in one run. Basically it consists of an electronic circuit and C++ program that controls the positioning of a sample holder in two axes of motion (X and Y). Each sample is transported and positioned, one by one, inside the shielding coupled to a high-purity germanium (HPGe) radiation detector. A Canberra DSA-1000 Multichannel Analyzer coupled to the Genie 2000 software performs the data acquisition for analysis of the samples. When the counting is finished the results are saved in a hard disk of a PC computer. The sample is brought back by the sample holder to its initial position, and the next sample is carried to the shielding. The Sample Changer was designed and constructed at IPEN-CNEN/SP by employing national components and expertise. (author)

  13. Evaluation of the maxillary premolar roots dissociation using radiographic holders with conventional and digital radiography

    Directory of Open Access Journals (Sweden)

    Marcia Regina Ramalho da Silva Bardauil

    2010-09-01

    Full Text Available This in vivo study evaluated the dissociation quality of maxillary premolar roots combining variations of vertical and horizontal angulations by using X-ray holders (Rinn -XCP, and made a comparison between two types of intraoral radiography systems - conventional film (Kodak Insight, Rochester, USA and digital radiography (Kodak RVG 6100, Kodak, Rochester, USA. The study sample was comprised of 20 patients with a total of 20 maxillary premolars that were radiographed, using the paralleling angle technique (GP, with a 20º variation of the horizontal angle (GM and 25º variation of the horizontal angle combined with 15º vertical angle (GMV. Each image was independently analyzed by two experienced examiners. These examiners assigned a score to the diagnostic capability of root dissociation and the measurement of the distance between the apexes. Statistical data was derived using the Wilcoxon Signed Rank test, Friedman and T test. The means of the measured distances between buccal and lingual root apexes were greater for the GMV, which ranged from 2.3 mm to 3.3 mm. A statistically significant difference was found between GM and GMV when compared to GP with p < 0.01. An established best diagnostic dissociation roots image was found in the GMV. These results support the use of the anterior X-ray holders which offer a better combined deviation (GMV to dissociate maxillary premolar roots in both radiography systems.

  14. Custom fit 3D-printed brain holders for comparison of histology with MRI in marmosets.

    Science.gov (United States)

    Guy, Joseph R; Sati, Pascal; Leibovitch, Emily; Jacobson, Steven; Silva, Afonso C; Reich, Daniel S

    2016-01-15

    MRI has the advantage of sampling large areas of tissue and locating areas of interest in 3D space in both living and ex vivo systems, whereas histology has the ability to examine thin slices of ex vivo tissue with high detail and specificity. Although both are valuable tools, it is currently difficult to make high-precision comparisons between MRI and histology due to large differences inherent to the techniques. A method combining the advantages would be an asset to understanding the pathological correlates of MRI. 3D-printed brain holders were used to maintain marmoset brains in the same orientation during acquisition of ex vivo MRI and pathologic cutting of the tissue. The results of maintaining this same orientation show that sub-millimeter, discrete neuropathological features in marmoset brain consistently share size, shape, and location between histology and ex vivo MRI, which facilitates comparison with serial imaging acquired in vivo. Existing methods use computational approaches sensitive to data input in order to warp histologic images to match large-scale features on MRI, but the new method requires no warping of images, due to a preregistration accomplished in the technique, and is insensitive to data formatting and artifacts in both MRI and histology. The simple method of using 3D-printed brain holders to match brain orientation during pathologic sectioning and MRI acquisition enables rapid and precise comparison of small features seen on MRI to their underlying histology. Published by Elsevier B.V.

  15. Social Perception of Hydrogen Technologies: The View of Spanish Stake holders; Percepcion Social de las Tecnologias del Hidrogeno. La Vision de los Stakeholders Espanoles

    Energy Technology Data Exchange (ETDEWEB)

    Ferri Anglada, S.

    2013-07-01

    This technical report presents an overview of the social perception and vision of a sample of Spanish stake holders on hydrogen technologies. The study is based on the implementation of a survey, combining both quantitative and qualitative data. An ad hoc electronic survey was design to collect views and perceptions on several key factors regarding this innovative energy alternative. The group of experts participating (N=130) in the study, comes mainly from research centers, universities and private companies. The survey addresses three major themes: expert views, social acceptability, and contextual factors of hydrogen technologies. The aim is to capture both the current and the future scene as viewed by the experts on hydrogen technologies, identifying key factors in terms of changes, uncertainties, obstacles and opportunities. The objective is to identify potential key features for the introduction, development, promotion, implementation, and large-scale deployment of a highly successful energy proposal in countries such as Iceland, one of the pioneers in base its economy on hydrogen technologies. To conclude, this report illustrates the positive engagement of a sample of Spanish stake holders towards hydrogen technologies that may prove vital in the transition towards the Hydrogen Economy in Spain. (Author)

  16. 48 CFR 252.205-7000 - Provision of information to cooperative agreement holders.

    Science.gov (United States)

    2010-10-01

    ... has an agreement with the Defense Logistics Agency to furnish procurement technical assistance to business entities. (b) The Contractor shall provide cooperative agreement holders, upon their request, with... defense contracts. The list shall include the business address, telephone number, and area of...

  17. Planetary Sample Caching System Design Options

    Science.gov (United States)

    Collins, Curtis; Younse, Paulo; Backes, Paul

    2009-01-01

    Potential Mars Sample Return missions would aspire to collect small core and regolith samples using a rover with a sample acquisition tool and sample caching system. Samples would need to be stored in individual sealed tubes in a canister that could be transfered to a Mars ascent vehicle and returned to Earth. A sample handling, encapsulation and containerization system (SHEC) has been developed as part of an integrated system for acquiring and storing core samples for application to future potential MSR and other potential sample return missions. Requirements and design options for the SHEC system were studied and a recommended design concept developed. Two families of solutions were explored: 1)transfer of a raw sample from the tool to the SHEC subsystem and 2)transfer of a tube containing the sample to the SHEC subsystem. The recommended design utilizes sample tool bit change out as the mechanism for transferring tubes to and samples in tubes from the tool. The SHEC subsystem design, called the Bit Changeout Caching(BiCC) design, is intended for operations on a MER class rover.

  18. Recent validation tests of the Edelweiss II detector holders

    International Nuclear Information System (INIS)

    Schwamm, F.; Chapellier, M.; Herve, S.; Karolak, M.; Navick, X.-F.

    2006-01-01

    A very good understanding of noise sources is highly important for the sensitivity of a dark matter search experiment. One of these noise contributions in the Edelweiss experiment could be the microphonics and temperature variations caused by vibrations of the cryostat. Recent studies complement an earlier work in describing the effect of the Edelweiss II detector holders on the amplitude of the vibrations seen by the detector. The results of these studies will be presented in this article

  19. Insider patent holder licensing in an oligopoly market with different cost structures: Fixed-fee, royalty, and auction

    OpenAIRE

    Ming-Chung Chang

    2010-01-01

    The issue of the optimal licensing contract in firms having different cost structures is studied when the innovator is a producing patent holder who has three alternative licensing strategies, namely, the fixed-fee, royalty rate, and auction strategies. We conclude that the auction licensing strategy is not the best strategy when the innovator is a producing patent holder. This finding differs from that of Kabiraj (2004) where the auction licensing method is the optimal licensing strategy whe...

  20. Adherence of volatile propofol to various types of plastic tubing.

    Science.gov (United States)

    Maurer, F; Lorenz, D J; Pielsticker, G; Volk, T; Sessler, D I; Baumbach, J I; Kreuer, S

    2017-01-23

    Propofol is an intravenous anesthetic. Currently, it is not possible to routinely measure blood concentration of the drug in real time. However, multi-capillary column ion-mobility spectrometry of exhaled gas can estimate blood propofol concentration. Unfortunately, adhesion of volatile propofol on plastic materials complicates measurements. Therefore, it is necessary to consider the extent to which volatile propofol adheres to various plastics used in sampling tubing. Perfluoralkoxy (PFA), polytetrafluorethylene (PTFE), polyurethane (PUR), silicone, and Tygon tubing were investigated in an experimental setting using a calibration gas generator (HovaCAL). Propofol gas was measured for one hour at 26 °C, 50 °C, and 90 °C tubing temperature. Test tubing segments were then flushed with N 2 to quantify desorption. PUR and Tygon sample tubing absorbed all volatile propofol. The silicone tubing reached the maximum propofol concentration after 119 min which was 29 min after propofol gas exposure stopped. The use of PFA or PTFE tubing produced comparable and reasonably accurate propofol measurements. The desaturation time for the PFA was 10 min shorter at 26 °C than for PTFE. PFA tubing thus seems most suitable for measurement of volatile propofol, with PTFE as an alternative.

  1. Steam generator tubing development for commercial fast breeder reactors

    International Nuclear Information System (INIS)

    Sessions, C.E.; Uber, C.F.

    1981-01-01

    The development work to design, manufacture, and evaluate pre-stressed double-wall 2/one quarter/ Cr-1 Mo steel tubing for commercial fast breeder reactor steam generator application is discussed. The Westinghouse plan for qualifying tubing vendors to produce this tubing is described. The results achieved to date show that a long length pre-stressed double-wall tube is both feasible and commercially available. The evaluation included structural analysis and experimental measurement of the pre-stress within tubes, as well as dimensional, metallurgical, and interface wear tests of tube samples produced. This work is summarized and found to meet the steam generator design requirements. 10 refs

  2. Landscape effects on pollinator communities and pollination services in small-holder agroecosystems

    NARCIS (Netherlands)

    Zou, Yi; Bianchi, Felix J.J.A.; Jauker, Frank; Xiao, Haijun; Chen, Junhui; Cresswell, James; Luo, Shudong; Huang, Jikun; Deng, Xiangzheng; Hou, Lingling; Werf, van der Wopke

    2017-01-01

    Pollination by insects is key for the productivity of many fruit and non-graminous seed crops, but little is known about the response of pollinators to landscapes dominated by small-holder agriculture. Here we assess the relationships between landscape context, pollinator communities (density and

  3. Development of a short sample test facility for evaluating superconducting wires

    International Nuclear Information System (INIS)

    Singh, M.R.; Kulkarni, D.G.; Sahni, V.C.; Ravikumar, G.; Patel, K.L.

    2002-01-01

    In this paper we describe a short sample test facility we have set up at Bhabha Atomic Research Centre (BARC). This facility has been used to measure critical currents of NbTi/Cu composite superconducting wires by recording V versus I data at 4.2 K. It offers sample current as large as 1500 A and a transverse magnetic field up to 7.4 T. A power law, V ∼I n( H) is fitted to the resistive transition region to estimate the exponent n, which is a measure of the uniformity of superconducting filaments in composite wires. It is observed that inadequate thermal stabilization of sample wire results in thermal runaway, which limits the V-I data to∼ 2μ V . This in turn affects the reliability of estimated filament uniformity. To mitigate this problem, we have used a sample holder made of OFHC-Cu which enhances thermal stabilization of the sample. With this sample holder, the results of measurements carried out on wires developed by the Atomic Fuel Division, BARC show a high filament uniformity (n ∼ 58). (author)

  4. Metal diffusion from furnace tubes depends on location

    International Nuclear Information System (INIS)

    Albright, L.F.

    1988-01-01

    Studies of metal samples from an ethylene furnace on the Texas Gulf Coast, using a scanning electron microscope (SEM) and an energy dispersive X-ray analyzer (EDAX), reveal preferential diffusion of chromium, titanium, and aluminum in the coil wall to the surfaces of the tube where they form metal oxides. These elements are gradually depleted from the tube wall. Complicated surface reactions that include the formation of several metal oxides, metal sulfides, and metal-catalyzed coke also occur. Several mechanisms can be postulated as to how metal fines or compounds are formed and transferred in the coil and transfer lines exchanger (TLX) of ethylene units. These surface reactions directly or indirectly affect coke formation in the tube. Finally, creep in the coils is likely a factor in promoting corrosion. Such creep is promoted by variable temperature-time patterns to which a coil is exposed during pyrolysis, and then decoking. Periods of stress and compression occur in the coil walls. Knowledge of the diffusion and reactions that take place can result in better furnace operations and decoking procedures to extend the life of the furnace tubes. In this second installment of a four-part series, photomicrographs of four pyrolysis tube samples from the ethylene furnace indicate that significant differences existed between the outer surfaces, inner surfaces, and cross-sectional areas of the samples. The first installment of the series dealt with coke

  5. Positioning X-Ray Film Inside A Flow Splitter

    Science.gov (United States)

    Darter, Charles; Pierce, Darryl

    1990-01-01

    Simple and inexpensive tool ensures secure placement for radiographic inspection. Holder places film positively and securely for x-ray inspection inside sections of tube with splitter welds. V-shaped piece of film fits on arms of holder. With arms squeezed together, holder inserted in opening of neck. Arms of holder cut from 0.020-in. (0.51-mm) thick stock of unspecified material.

  6. Do people really want freedom of choice? : Assessing preferences of pension holders

    NARCIS (Netherlands)

    van Dalen, Harry; Henkens, Kene

    2018-01-01

    Reforms of private pension plans across the world are involving the introduction of more options for pension holders to make choices to suit their preferences. Freedom of choice is not, however, a unidimensional concept despite being commonly perceived as such by policy makers. Using a unique panel

  7. Stability of Cortisol and Cortisone in Human Breast Milk During Holder Pasteurization

    NARCIS (Netherlands)

    van der Voorn, Bibian; de Waard, Marita; Dijkstra, Lisette R.; Heijboer, Annemieke C.; Rotteveel, Joost; van Goudoever, Johannes B.; Finken, Martijn J. J.

    2017-01-01

    Human donor milk is the feeding of choice for preterm infants, when own mother's milk is not available. Holder pasteurization is necessary to secure the safety of donor milk, although it can affect milk quality by reduction of nutritional and bioactive components. Recently, research has focused on

  8. The second eddy current testing of zircaloy tube samples from the OECD Halden reactor project at Reactor Fuel Examination Facility, Tokai, JAERI

    International Nuclear Information System (INIS)

    Ohwada, Isao; Nishino, Yasuharu

    1986-07-01

    The Reactor Fuel Examination Facility in Tokai/JAERI (Japan Atomic Energy Research Institute) joined to the second round robin programme on eddy current test of the Halden/IFE. In the programme, two zircaloy tube samples with some artificial defects were provided for measurements. To clarify the locations in axial and azimuthal directions, types and dimensions of the provided artificial defects, measured signals from eddy current test were analysed in comparison with the known defects on the calibration tube. As a result, fourteen defects were determined from the measurements. Then, the location, the type and the relative dimension of them were also revealed. The results of those eddy current test are described in this paper. (author)

  9. Automatic measuring system of zirconium thickness for zirconium liner cladding tubes

    International Nuclear Information System (INIS)

    Matsui, K.; Yamaguchi, H.; Hiroshima, T.; Sakamoto, T.; Murayama, R.

    1985-01-01

    An automatic system of pure zirconium liner thickness for zirconium-zircaloy cladding tubes has been successfully developed. The system consists of three parts. (1) An ultrasonic thickness measuring method for mother tubes before cold rolling. (2) An electromagnetic thickness measuring method for the manufactured tubes. (3) An image processing method for the cross sectional view of the manufactured cut tube samples. In Japanese nuclear industry, zirconium-zircaloy cladding tubes have been tested in order to realize load following operation in the atomic power plant. In order to provide for the practical use in the near future, Sumitomo Metal Industries, Ltd. has been studied and established the practical manufacturing process of the zirconium liner cladding tubes. The zirconium-liner cladding tube is a duplex tube comprising an inner layer of pure zirconium bonded to zircaloy metallurgically. The thickness of the pure zirconium is about 10 % of the total wall thickness. Several types of the automatic thickness measuring methods have been investigated instead of the usual microscopic viewing method in which the liner thickness is measured by the microscopic cross sectional view of the cut tube samples

  10. Shielded scanning electron microscope for radioactive samples

    International Nuclear Information System (INIS)

    Crouse, R.S.; Parsley, W.B.

    1977-01-01

    A small commercial SEM had been successfully shielded for examining radioactive materials transferred directly from a remote handling facility. Relatively minor mechanical modifications were required to achieve excellent operation. Two inches of steel provide adequate shielding for most samples encountered. However, samples reading 75 rad/hr γ have been examined by adding extra shielding in the form of tungsten sample holders and external lead shadow shields. Some degradation of secondary electron imaging was seen but was adequately compensated for by changing operating conditions

  11. New tool holder design for cryogenic machining of Ti6Al4V

    Science.gov (United States)

    Bellin, Marco; Sartori, Stefano; Ghiotti, Andrea; Bruschi, Stefania

    2017-10-01

    The renewed demand of increasing the machinability of the Ti6Al4V titanium alloy to produce biomedical and aerospace parts working at high temperature has recently led to the application of low-temperature coolants instead of conventional cutting fluids to increase both the tool life and the machined surface integrity. In particular, the liquid nitrogen directed to the tool rake face has shown a great capability of reducing the temperature at the chip-tool interface, as well as the chemical interaction between the tool coating and the titanium to be machined, therefore limiting the tool crater wear, and improving, at the same time, the chip breakability. Furthermore, the nitrogen is a safe, non-harmful, non-corrosive, odorless, recyclable, non-polluting and abundant gas, characteristics that further qualify it as an environmental friendly coolant to be applied to machining processes. However, the behavior of the system composed by the tool and the tool holder, exposed to the cryogenics temperatures may represent a critical issue in order to obtain components within the required geometrical tolerances. On this basis, the paper aims at presenting the design of an innovative tool holder installed on a CNC lathe, which includes the cryogenic coolant provision system, and which is able to hinder the part possible distortions due to the liquid nitrogen adduction by stabilizing its dimensions through the use of heating cartridges and appropriate sensors to monitor the temperature evolution of the tool holder.

  12. Assessment of need for transport tubes when continuously monitoring for radioactive aerosols.

    Science.gov (United States)

    Whicker, J J; Rodgers, J C; Lopez, R C

    1999-09-01

    Aerosol transport tubes are often used to draw aerosol from desirable sampling locations to nearby air sampling equipment that cannot be placed at that location. In many plutonium laboratories at Los Alamos National Laboratory, aerosol transport tubes are used to transport aerosol from the front of room ventilation exhaust registers to continuous air monitors (CAMs) that are mounted on nearby walls. Transport tubes are used because past guidance suggests that extraction of aerosol samples from exhaust locations provides the most sensitive and reliable detection under conditions where the rooms have unpredictable release locations and significant spatial variability in aerosol concentrations after releases, and where CAMs cannot be located in front of exhaust registers without blocking worker walkways. Despite designs to minimize particle loss in tubes, aerosol transport model predictions suggest losses occur lowering the sensitivity of CAMs to accidentally released plutonium aerosol. The goal of this study was to test the hypotheses that the reliability, speed, and sensitivity of aerosol detection would be equal whether the sample was extracted from the front of the exhaust register or from the wall location of CAMs. Polydisperse oil aerosols were released from multiple locations in two plutonium laboratories to simulate plutonium aerosol releases. Networked laser particle counters (LPCs) were positioned to simultaneously measure time-resolved aerosol concentrations at each exhaust register (representative of sampling with transport tubes) and at each wall-mounted CAM location (representative of sampling without transport tubes). Results showed no significant differences in detection reliability, speed, or sensitivity for LPCs positioned at exhaust locations when compared to LPCs positioned at the CAM wall location. Therefore, elimination of transport tubes would likely improve CAM performance.

  13. Initial experience using a robotic-driven laparoscopic needle holder with ergonomic handle: assessment of surgeons' task performance and ergonomics.

    Science.gov (United States)

    Sánchez-Margallo, Juan A; Sánchez-Margallo, Francisco M

    2017-12-01

    The objective of this study is to assess the surgeons' performance and ergonomics during the use of a robotic-driven needle holder in laparoscopic suturing tasks. Six right-handed laparoscopic surgeons with different levels of experience took part in this study. Participants performed a set of three different intracorporeal suturing tasks organized in ten trials during a period of five weeks. Surgeons used both conventional (Conv) and robotic (Rob) laparoscopic needle holders. Precision using the surgical needle, quality of the intracorporeal suturing performance, execution time and leakage pressure for the urethrovesical anastomosis, as well as the ergonomics of the surgeon's hand posture, were analyzed during the first, fifth and last trials. No statistically significant differences in precision and quality of suturing performance were obtained between both groups of instruments. Surgeons required more time using the robotic instrument than using the conventional needle holder to perform the urethrovesical anastomosis, but execution time was significantly reduced after training ([Formula: see text] 0.05). There were no differences in leakage pressure for the anastomoses carried out by both instruments. After training, novice surgeons significantly improved the ergonomics of the wrist ([Formula: see text] 0.05) and index finger (Conv: 36.381[Formula: see text], Rob: 30.389[Formula: see text]; p = 0.024) when using the robotic instrument compared to the conventional needle holder. Results have shown that, although both instruments offer similar technical performance, the robotic-driven instrument results in better ergonomics for the surgeon's hand posture compared to the use of a conventional laparoscopic needle holder in intracorporeal suturing.

  14. Custom Fit 3D-Printed Brain Holders for Comparison of Histology with MRI in Marmosets

    Science.gov (United States)

    Guy, Joseph R.; Sati, Pascal; Leibovitch, Emily; Jacobson, Steven; Silva, Afonso C.; Reich, Daniel S.

    2015-01-01

    Background MRI has the advantage of sampling large areas of tissue and locating areas of interest in 3D space in both living and ex vivo systems, whereas histology has the ability to examine thin slices of ex vivo tissue with high detail and specificity. Although both are valuable tools, it is currently difficult to make high-precision comparisons between MRI and histology due to large differences inherent to the techniques. A method combining the advantages would be an asset to understanding the pathological correlates of MRI. New Method 3D-printed brain holders were used to maintain marmoset brains in the same orientation during acquisition of ex vivo MRI and pathologic cutting of the tissue. Results The results of maintaining this same orientation show that sub-millimeter, discrete neuropathological features in marmoset brain consistently share size, shape, and location between histology and ex vivo MRI, which facilitates comparison with serial imaging acquired in vivo. Comparison with Existing Methods Existing methods use computational approaches sensitive to data input in order to warp histologic images to match large-scale features on MRI, but the new method requires no warping of images, due to a preregistration accomplished in the technique, and is insensitive to data formatting and artifacts in both MRI and histology. Conclusions The simple method of using 3D-printed brain holders to match brain orientation during pathologic sectioning and MRI acquisition enables rapid and precise comparison of small features seen on MRI to their underlying histology. PMID:26365332

  15. Ultrafine-grained porous titanium and porous titanium/magnesium composites fabricated by space holder-enabled severe plastic deformation

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Yuanshen, E-mail: yuanshen.qi@monash.edu [Centre for Advanced Hybrid Materials, Department of Materials Engineering, Monash University, Clayton, Victoria 3800 (Australia); Contreras, Karla G. [Monash Institute of Medical Engineering, Faculty of Engineering, Monash University, Clayton, Victoria 3800 (Australia); Jung, Hyun-Do [Liquid Processing & Casting Technology R& D Group, Korea Institute of Industrial Technology, Incheon 406-840 (Korea, Republic of); Department of Materials Science and Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of); Kim, Hyoun-Ee [Department of Materials Science and Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of); Advanced Institutes of Convergence Technology, Seoul National University, Gwanggyo, Yeongtong-gu, Suwon-si, Gyeonggi-do 443-270 (Korea, Republic of); Lapovok, Rimma [Centre for Advanced Hybrid Materials, Department of Materials Engineering, Monash University, Clayton, Victoria 3800 (Australia); Estrin, Yuri, E-mail: yuri.estrin@monash.edu [Centre for Advanced Hybrid Materials, Department of Materials Engineering, Monash University, Clayton, Victoria 3800 (Australia); Laboratory of Hybrid Nanostructured Materials, NUST MISiS, Moscow 119490 (Russian Federation)

    2016-02-01

    Compaction of powders by equal channel angular pressing (ECAP) using a novel space holder method was employed to fabricate metallic scaffolds with tuneable porosity. Porous Ti and Ti/Mg composites with 60% and 50% percolating porosity were fabricated using powder blends with two kinds of sacrificial space holders. The high compressive strength and good ductility of porous Ti and porous Ti/Mg obtained in this way are believed to be associated with the ultrafine grain structure of the pore walls. To understand this, a detailed electron microscopy investigation was employed to analyse the interface between Ti/Ti and Ti/Mg particles, the grain structures in Ti particles and the topography of pore surfaces. It was found that using the proposed compaction method, high quality bonding between particles was obtained. Comparing with other powder metallurgy methods to fabricate Ti with an open porous structure, where thermal energy supplied by a laser beam or high temperature sintering is essential, the ECAP process conducted at a relatively low temperature of 400 °C was shown to produce unique properties. - Highlights: • Porous Ti and porous Ti/Mg composite scaffolds were fabricated successfully. • Space holder-enabled severe plastic deformation was first used in this application. • Silicon particles as sacrificial space holders were used for the first time. • Ultrafine-grained microstructure and good bonding between particles were obtained. • Good preosteoblast cell response to as-manufactured porous Ti was achieved.

  16. An investigation on mechanical property of commercial copper tube to aluminium 2025 tube plate by FWTPET process

    Energy Technology Data Exchange (ETDEWEB)

    Kannan, S., E-mail: kannan.dgl201127@gmail.com [Department of Mechanical Engineering and Mining Machinery Engineering, Indian Institute of Technology (ISM), Dhanbad, Jharkhand 826004 (India); Senthil Kumaran, S., E-mail: sskumaran@ymail.com [Research and Development Center, Department of Mechanical Engineering, RVS Educational Trust' s Group of Institutions, RVS School of Engineering and Technology, Dindigul, Tamilnadu 624005 (India); Kumaraswamidhas, L.A., E-mail: lakdhas1978@gmail.com [Department of Mechanical Engineering and Mining Machinery Engineering, Indian Institute of Technology (ISM), Dhanbad, Jharkhand 826004 (India)

    2016-07-05

    Frictional welding of tube to tube plate by external tool (FWTPET) posses wide spread industrial in mass production process for joint similar and dissimilar materials. Frictional welding process allows welding of some materials that are exceptionally hard to fusion weld. The good quality joint between the tube and tube plate is achieved by selecting the proper process parameter. In this present research, the frictional welding is done between the Aluminium 2025 tube plate and commercial copper tube possessing a clearance fit of 0.1 mm between tube and hole. In this study, two conditions were considered while handing out this experiment. The condiction1 is tube without holes [WOH] and condition 2 is tube with holes [WH] on the tube circumference. In total, twenty seven work pieces have been considered separately for both conditions and the mechanical property such as compression strength and hardness value has been measured for the both set of work piece in two conditions to analysis the joint strength of the welding process. Taguchi L{sub 27} orthogonal array has been used in this process to identify the process parameter which influences the joint strength of the welded samples. ANOVA method is used to calculate the percentage of contribution by each process parameter which influences the better joint strength. Genetic algorithm is used to authenticate the outcome obtained from the both experimental value and optimization value. Scanning Electron Microscope (SEM) and Energy-dispersive X-ray analysis (EDX) has been performed to probe microstructures and chemical compositions for work piece without holes which has higher mechanical property. - Highlights: • FWTPET for dissimilar metals commercial copper tube and Al 2025 tube plate. • The hardness value for tube without holes are 180.988 Hv. • The compression strength for tube without holes are 376.05 MPa. • SEM confirm heat production is done to melt parent metal by diffusion process. • EDX prove no trace

  17. 21 CFR 868.5800 - Tracheostomy tube and tube cuff.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tracheostomy tube and tube cuff. 868.5800 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5800 Tracheostomy tube and tube cuff. (a) Identification. A tracheostomy tube and tube cuff is a device intended to be placed into a...

  18. Tagging of Test Tubes with Electronic p-Chips for Use in Biorepositories.

    Science.gov (United States)

    Mandecki, Wlodek; Kopacka, Wesley M; Qian, Ziye; Ertwine, Von; Gedzberg, Katie; Gruda, Maryann; Reinhardt, David; Rodriguez, Efrain

    2017-08-01

    A system has been developed to electronically tag and track test tubes used in biorepositories. The system is based on a light-activated microtransponder, also known as a "p-Chip." One of the pressing problems with storing and retrieving biological samples at low temperatures is the difficulty of reliably reading the identification (ID) number that links each storage tube with the database containing sample details. Commonly used barcodes are not always reliable at low temperatures because of poor adhesion of the label to the test tube and problems with reading under conditions of frost and ice accumulation. Traditional radio frequency identification (RFID) tags are not cost effective and are too large for this application. The system described herein consists of the p-Chip, p-Chip-tagged test tubes, two ID readers (for single tubes or for racks of tubes), and software. We also describe a robot that is configured for retrofitting legacy test tubes in biorepositories with p-Chips while maintaining the temperature of the sample below -50°C at all times. The main benefits of the p-Chip over other RFID devices are its small size (600 × 600 × 100 μm) that allows even very small tubes or vials to be tagged, low cost due to the chip's unitary construction, durability, and the ability to read the ID through frost and ice.

  19. Tube plug

    International Nuclear Information System (INIS)

    Zafred, P. R.

    1985-01-01

    The tube plug comprises a one piece mechanical plug having one open end and one closed end which is capable of being inserted in a heat exchange tube and internally expanded into contact with the inside surface of the heat exchange tube for preventing flow of a coolant through the heat exchange tube. The tube plug also comprises a groove extending around the outside circumference thereof which has an elastomeric material disposed in the groove for enhancing the seal between the tube plug and the tube

  20. Ultrasonic inspection of tube to tube plate welds

    International Nuclear Information System (INIS)

    Telford, D.W.; Peat, T.S.

    1985-01-01

    To monitor the deterioration of a weld between a tube and tube plate which has been repaired by a repair sleeve inside the tube and brazed at one end to the tube, ultrasound from a crystal at the end of a rod is launched, in the form of Lamb-type waves, into the tube through the braze and allowed to travel along the tube to the weld and be reflected back along the tube. The technique may also be used for the type of heat exchanger in which, during construction, the tubes are welded to the tube plate via external sleeves in which case the ultrasound is used in a similar manner to inspect the sleeve/tube plate weld. an electromagnetic transducer may be used to generate the ultrasound. The ultrasonic head comprising the crystal and an acoustic baffle is mounted on a Perspex (RTM) rod which may be rotated by a stepping motor. Echo signals from the region of deterioration may be isolated by use of a time gate in the receiver. The device primarily detects circumferentially orientated cracks, and may be used in heat exchangers in nuclear power plants. (author)

  1. Surface sampling concentration and reaction probe

    Science.gov (United States)

    Van Berkel, Gary J; Elnaggar, Mariam S

    2013-07-16

    A method of analyzing a chemical composition of a specimen is described. The method can include providing a probe comprising an outer capillary tube and an inner capillary tube disposed co-axially within the outer capillary tube, where the inner and outer capillary tubes define a solvent capillary and a sampling capillary in fluid communication with one another at a distal end of the probe; contacting a target site on a surface of a specimen with a solvent in fluid communication with the probe; maintaining a plug volume proximate a solvent-specimen interface, wherein the plug volume is in fluid communication with the probe; draining plug sampling fluid from the plug volume through the sampling capillary; and analyzing a chemical composition of the plug sampling fluid with an analytical instrument. A system for performing the method is also described.

  2. TEM examination of irradiated zircaloy-2 pressure tube material

    International Nuclear Information System (INIS)

    Srivastava, D.; Tewari, R.; Dey, G.K.; Sharma, B.P.; Sah, D.N.; Banerjee, Suparna; Sahoo, K.C.

    2005-09-01

    In the present work, microstructure of the zircaloy-2 pressure tube material irradiated in the Indian Pressurized Heavy Water RAPP-1. Reactor (PHWR) has been examined for the first time using transmission electron microscope (TEM). The samples were obtained from a zircaloy-2 pressure tube, which had been in operation in the high flux region of Rajasthan Atomic Power Station Unit -1, for a period for 6.77 effective full power years (EFPYs) and expected to have a cumulative radiation damage of about 3 dpa. In this study irradiated microstructure has been characterized and compared it with the microstructure of the unirradiated pressure tube samples. The effect of irradiation on the hydriding behaviour is also studied. (author)

  3. Delayed hydrogen cracking test design for pressure tubes

    International Nuclear Information System (INIS)

    Haddad, Roberto; Loberse, Antonio N.; Yawny, Alejandro A.; Riquelme, Pablo

    1999-01-01

    CANDU nuclear power stations pressure tubes of alloy Zr-2,5 % Nb present a cracking phenomenon known as delayed hydrogen cracking (DHC). This is a brittle fracture of zirconium hydrides that are developed by hydrogen due to aqueous corrosion on the metal surface. This hydrogen diffuses to the crack tip where brittle zirconium hydrides develops and promotes the crack propagation. A direct current potential decay (DCPD) technique has been developed to measure crack propagation rates on compact test (CT) samples machined from a non irradiated pressure tube. Those test samples were hydrogen charged by cathodic polarization in an acid solution and then pre cracked in a fatigue machine. This technique proved to be useful to measure crack propagation rates with at least 1% accuracy for DHC in pressure tubes. (author)

  4. Investigation of holder pressure and size effects in micro deep drawing of rectangular work pieces driven by piezoelectric actuator.

    Science.gov (United States)

    Aminzahed, Iman; Mashhadi, Mahmoud Mosavi; Sereshk, Mohammad Reza Vaziri

    2017-02-01

    Micro forming is a manufacturing process to fabricate micro parts with high quality and a cost effective manner. Deep drawing could be a favorable method for production of complicated parts in macro and micro sizes. In this paper piezoelectric actuator is used as a novel approach in the field of micro manufacturing. Also, in current work, investigations are conducted with four rectangular punches and blanks with various thicknesses. Blank holder pressure effects on thickness distributions, punch force, and springback are studied. According to the results of this work, increasing of blank holder pressure in scaled deep drawing, in contrast to thickness of drawn part, leads to decrease in the punch forces and springback. Furthermore, it is shown that in micro deep drawing, the effects of holder pressure on mentioned parameters can be ignored. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Influence of the collection tube on metabolomic changes in serum and plasma.

    Science.gov (United States)

    López-Bascón, M A; Priego-Capote, F; Peralbo-Molina, A; Calderón-Santiago, M; Luque de Castro, M D

    2016-04-01

    Major threats in metabolomics clinical research are biases in sampling and preparation of biological samples. Bias in sample collection is a frequently forgotten aspect responsible for uncontrolled errors in metabolomics analysis. There is a great diversity of blood collection tubes for sampling serum or plasma, which are widely used in metabolomics analysis. Most of the existing studies dealing with the influence of blood collection on metabolomics analysis have been restricted to comparison between plasma and serum. However, polymeric gel tubes, which are frequently proposed to accelerate the separation of serum and plasma, have not been studied. In the present research, samples of serum or plasma collected in polymeric gel tubes were compared with those taken in conventional tubes from a metabolomics perspective using an untargeted GC-TOF/MS approach. The main differences between serum and plasma collected in conventional tubes affected to critical pathways such as the citric acid cycle, metabolism of amino acids, fructose and mannose metabolism and that of glycerolipids, and pentose and glucuronate interconversion. On the other hand, the polymeric gel only promoted differences at the metabolite level in serum since no critical differences were observed between plasma collected with EDTA tubes and polymeric gel tubes. Thus, the main changes were attributable to serum collected in gel and affected to the metabolism of amino acids such as alanine, proline and threonine, the glycerolipids metabolism, and two primary metabolites such as aconitic acid and lactic acid. Therefore, these metabolite changes should be taken into account in planning an experimental protocol for metabolomics analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Liquid waste sampling device

    International Nuclear Information System (INIS)

    Kosuge, Tadashi

    1998-01-01

    A liquid pumping pressure regulator is disposed on the midway of a pressure control tube which connects the upper portion of a sampling pot and the upper portion of a liquid waste storage vessel. With such a constitution, when the pressure in the sampling pot is made negative, and liquid wastes are sucked to the liquid pumping tube passing through the sampling pot, the difference between the pressure on the entrance of the liquid pumping pressure regulator of the pressure regulating tube and the pressure at the bottom of the liquid waste storage vessel is made constant. An opening degree controlling meter is disposed to control the degree of opening of a pressure regulating valve for sending actuation pressurized air to the liquid pumping pressure regulator. Accordingly, even if the liquid level of liquid wastes in the liquid waste storage vessel is changed, the height for the suction of the liquid wastes in the liquid pumping tube can be kept constant. With such procedures, sampling can be conducted correctly, and the discharge of the liquid wastes to the outside can be prevented. (T.M.)

  7. Investigation of the effects of process and geometrical parameters on formability in tube hydroforming using a modular hydroforming tool

    Science.gov (United States)

    Joghan, Hamed Dardaei; Staupendahl, Daniel; Hassan, Hamad ul; Henke, Andreas; Keesser, Thorsten; Legat, Francois; Tekkaya, A. Erman

    2018-05-01

    Tube hydroforming is one of the most important manufacturing processes for the production of exhaust systems. Tube hydroforming allows generating parts with highly complex geometries with the forming accuracies needed in the automotive sector. This is possible due to the form-closed nature of the production process. One of the main cost drivers is tool manufacturing, which is expensive and time consuming, especially when forming large parts. To cope with the design trend of individuality, which is gaining more and more importance and leads to a high number of product variants, a new flexible tool design was developed. The designed tool offers a high flexibility in manufacturing different shapes and geometries of tubes with just local alterations and relocation of tool segments. The tolerancing problems that segmented tools from the state of the art have are overcome by an innovative and flexible die holder design. The break-even point of this initially more expensive tool design is already overcome when forming more than 4 different tube shapes. Together with an additionally designed rotary hydraulic tube feeding system, a highly adaptable forming setup is generated. To investigate the performance of the developed tool setup, a study on geometrical and process parameters during forming of a spherical dome was done. Austenitic stainless steel (grade 1.4301) tube with a diameter of 40 mm and a thickness of 1.5 mm was used for the investigations. The experimental analyses were supported by finite element simulations and statistical analyses. The results show that the flexible tool setup can efficiently be used to analyze the interaction of the inner pressure, friction, and the location of the spherical dome and demonstrate the high influence of the feeding rate on the formed part.

  8. Gasket-holder to put in place gaskets for connection of pipes with clamp fittings

    International Nuclear Information System (INIS)

    Fiori, R.

    1989-01-01

    Gasket-holder comprising 2 arms with tongues holding the gasket and fixing devices on a pipe clamp fitting and centering means. Application is made to fit circular gaskets on pipe with conic end in adverse environment [fr

  9. Manipulator for inspection or repair of heat exchanger tubes, in particular in steam generators for nuclear reactors

    International Nuclear Information System (INIS)

    Gugel, G.

    1979-01-01

    The manipulator used to inspect or repair pipes in the steam generator chamber of a PWR can be introduced and removed through a penetration nozzle which can be sealed tightly by means of a blind flange. The front end of the manipulator carries a swivel arm which can be operated remotely to be moved in a plane parallel to the tube plate. The end of the swivel arm carries a holder for a mouthpiece which can be extended and retracted. This carrier can also be operated remotely so as to be aligned to the pipe orifices in a direction normal to the swivel plane of the swivel arm. The manipulator is supported in antifriction bearings in the penetration nozzle so as to be movable longitudinally. (DG) [de

  10. Advances in the sample preparation and the detector for a combined solvent extraction-liquid scintillation method of low-level plutonium measurement

    International Nuclear Information System (INIS)

    Perdue, P.T.; Christian, D.J.; Thorngate, J.H.; McDowell, W.J.; Case, G.N.

    1976-07-01

    A combined solvent extraction-liquid scintillation technique, developed at Oak Ridge National Laboratory (ORNL), has many possible applications to the determination of low levels of plutonium and other alpha-emitting nuclides. Using these procedures, plutonium can be extracted from biological or environmental samples and introduced directly into a liquid scintillator. Quenching of the scintillator is thus minimized so that spectroscopic techniques may be employed. Existing chemical procedures and counting equipment were reviewed and improved. Purification of the di(2-ethylhexyl)phosphoric acid (used as the actinide extractant) was found necessary. Destruction of organic material in the sample and control of the valence state of plutonium were found to be major sources of irreproducibility. Methods were developed to allow samples separated with commonly used ion exchange techniques to be extracted into the scintillator. Comparisons were made of a wide variety of the components and parameters of the detector system to find the best combination of pulse-height resolution and pulse-shape discrimination. When a single phototube was used, optimum performance was obtained using a hemispherical reflector-sample holder viewed sideways by an RCA 8575 photomultiplier tube used in conjunction with a special integrating preamplifier and a good quality linear amplifier that used delay lines to shape the pulses

  11. Tube spacer grid for a heat-exchanger tube bundle

    International Nuclear Information System (INIS)

    Scheidl, H.

    1976-01-01

    A tube spacer grid for a heat-exchanger tube bundle is formed by an annular grid frame having a groove formed in its inner surface in which the interspaced grid bars have their ends positioned and held in interspaced relationship by short sections of tubes passed through holes axially formed in the grid frame so that the tubes are positioned between the ends of the grid bars in the grooves. The tube sections may be cut from the same tubes used to form the tube bundle. 5 claims, 3 drawing figures

  12. CFD modeling of a boiler's tubes rupture

    International Nuclear Information System (INIS)

    Rahimi, Masoud; Khoshhal, Abbas; Shariati, Seyed Mehdi

    2006-01-01

    This paper reports the results of a study on the reason for tubes damage in the superheater Platen section of the 320 MW Bisotoun power plant, Iran. The boiler has three types of superheater tubes and the damage occurs in a series of elbows belongs to the long tubes. A three-dimensional modeling was performed using an in-house computational fluid dynamics (CFD) code in order to explore the reason. The code has ability of simultaneous solving of the continuity, the Reynolds-Averaged Navier-Stokes (RANS) equations and employing the turbulence, combustion and radiation models. The whole boiler including; walls, burners, air channels, three types of tubes, etc., was modeled in the real scale. The boiler was meshed into almost 2,000,000 tetrahedral control volumes and the standard k-ε turbulence model and the Rosseland radiation model were used in the model. The theoretical results showed that the inlet 18.9 MPa saturated steam becomes superheated inside the tubes and exit at a pressure of 17.8 MPa. The predicted results showed that the temperature of the steam and tube's wall in the long tubes is higher than the short and medium size tubes. In addition, the predicted steam mass flow rate in the long tube was lower than other ones. Therefore, it was concluded that the main reason for the rupture in the long tubes elbow is changing of the tube's metal microstructure due to working in a temperature higher than the design temperature. In addition, the structural fatigue tension makes the last elbow of the long tube more ready for rupture in comparison with the other places. The concluded result was validated by observations from the photomicrograph of the tube's metal samples taken from the damaged and undamaged sections

  13. Validating YouTube Factors Affecting Learning Performance

    Science.gov (United States)

    Pratama, Yoga; Hartanto, Rudy; Suning Kusumawardani, Sri

    2018-03-01

    YouTube is often used as a companion medium or a learning supplement. One of the educational places that often uses is Jogja Audio School (JAS) which focuses on music production education. Music production is a difficult material to learn, especially at the audio mastering. With tutorial contents from YouTube, students find it easier to learn and understand audio mastering and improved their learning performance. This study aims to validate the role of YouTube as a medium of learning in improving student’s learning performance by looking at the factors that affect student learning performance. The sample involves 100 respondents from JAS at audio mastering level. The results showed that student learning performance increases seen from factors that have a significant influence of motivation, instructional content, and YouTube usefulness. Overall findings suggest that YouTube has a important role to student learning performance in music production education and as an innovative and efficient learning medium.

  14. Gamma irradiation effect on thermo shrink polyethylene tube: Case study

    International Nuclear Information System (INIS)

    Naurah Mat Isa; Siti Zulaiha Hairaldin; Mohd Yusof Hamzah; Zulkafli Ghazali

    2010-01-01

    The production technology of heat shrinkable tubes is based on the industrial usage of so-called memory effect in some polymers. Many polymers can be rendered heat shrinkable, particularly polyolefins by introducing crosslinking in the polymer backbone. Heat shrinkable tubes and moulded parts provide mechanical and/or chemical and/or electrical protection. . In this work, irradiation from Co-60 was used to impart crosslinking in polymer and thus modify their mechanical and thermal properties. Heat shrinkable or thermo shrink polyethylene (PE) tube with diameter 6.4 mm was selected to evaluate crosslinking behaviour from the gamma irradiation exposure at 5 different doses (120, 140, 160, 200 and 220 kGy). The gel content (%), tensile properties and thermal behavior and stability of the tubes were measured using DSC and TGA. Tubes irradiated at 140 kGy and 160 kGy showed better tensile properties than those at 120, 200 and 220 kGy doses. Maximum percent of crystallization was observed at 160 kGy and temperature required to crystallize is lower than melting temperature due to changes in molecular orientation. Thermal decomposition of the irradiated tubes occurred at 430-450 degree Celsius which is lower than the unirradiated sample. Gel content analysis for samples irradiated at 180-220 kGy yield up to 30 to 40 % gel fraction. Although the gel fractions are higher than other dose, the samples are expected to experience chain scission presumably due to localized gel formation. (author)

  15. Lack of association between folate-receptor autoantibodies and neural-tube defects.

    LENUS (Irish Health Repository)

    Molloy, Anne M

    2009-07-09

    BACKGROUND: A previous report described the presence of autoantibodies against folate receptors in 75% of serum samples from women with a history of pregnancy complicated by a neural-tube defect, as compared with 10% of controls. We sought to confirm this finding in an Irish population, which traditionally has had a high prevalence of neural-tube defects. METHODS: We performed two studies. Study 1 consisted of analysis of stored frozen blood samples collected from 1993 through 1994 from 103 mothers with a history of pregnancy complicated by a neural-tube defect (case mothers), 103 mothers with a history of pregnancy but no complication by a neural-tube defect (matched with regard to number of pregnancies and sampling dates), 58 women who had never been pregnant, and 36 men. Study 2, conducted to confirm that the storage of samples did not influence the folate-receptor autoantibodies, included fresh samples from 37 case mothers, 22 control mothers, 10 women who had never been pregnant, and 9 men. All samples were assayed for blocking and binding autoantibodies against folate receptors. RESULTS: In Study 1, blocking autoantibodies were found in 17% of case mothers, as compared with 13% of control mothers (odds ratio, 1.54; 95% confidence interval [CI], 0.70 to 3.39), and binding autoantibodies in 29%, as compared with 32%, respectively (odds ratio, 0.82; 95% CI, 0.44 to 1.50). Study 2 showed similar results, indicating that sample degradation was unlikely. CONCLUSIONS: The presence and titer of maternal folate-receptor autoantibodies were not significantly associated with a neural-tube defect-affected pregnancy in this Irish population.

  16. Evaluation of a single-tube fluorogenic RT-PCR assay for detection of bovine respiratory syncytial virus in clinical samples

    DEFF Research Database (Denmark)

    Hakhverdyan, Mikhayil; Hägglund, Sara; Larsen, Lars Erik

    2005-01-01

    understanding of the virus. In this study, a BRSV fluorogenic reverse transcription PCR (fRT-PCR) assay, based on TaqMan principle, was developed and evaluated on a large number of clinical samples, representing various cases of natural and experimental BRSV infections. By using a single-step closed-tube format......, the turn-around time was shortened drastically and results were obtained with minimal risk for cross-contamination. According to comparative analyses, the detection limit of the fRT-PCR was on the same level as that of a nested PCR and the sensitivity relatively higher than that of a conventional PCR......, antigen ELISA (Ag-ELISA) and virus isolation (VI). Interspersed negative control samples, samples from healthy animals and eight symptomatically or genetically related viruses were all negative, confirming a high specificity of the assay. Taken together, the data indicated that the fRT-PCR assay can...

  17. Pseudohyperkalaemia in leukaemic patients: the effect of test tube type and form of transport to the laboratory.

    Science.gov (United States)

    Dastych, Milan; Cermáková, Zdenka

    2014-01-01

    The present study was aimed at determining the effect of the tube type used for primary sample collection and the manner of transport prior to assessment (either manual or by pneumatic tube) on the degree of pseudohyperkalaemia in leukaemic patients. Blood from six leukaemic patients was collected into seven primary sample tubes (Monovette®, Sarstedt): sample A, heparinized blood gas syringe (potassium reference value); sample B, plasma Li-heparin without separator gel; sample C, plasma Li-heparin with separator gel; and sample D, serum with separator gel. The primary sample tubes designated B, C and D were transported to the laboratory manually. Duplicates of the same sample tubes, B(PT), C(PT) and D(PT), were sent to the laboratory by pneumatic tube. In patients with chronic lymphocytic leukaemia (CLL), there was no increase in the concentration of potassium in samples B, C and D when compared to the reference value. Transport of the samples by pneumatic tube led to a pronounced increase in potassium concentration in samples B(PT) and C(PT), whereas there was no increase in sample D(PT) when compared to the reference value. In the patient with chronic myeloid leukaemia (CML), an increase in potassium concentration occurred in sample D and in samples B(PT), C(PT) and D(PT). A similar finding was observed in the patient with acute lymphocytic leukaemia (ALL), furthermore with an extremely high concentration of potassium in samples C and C(PT). Manual transport of non-coagulable blood (plasma Li-heparin without separator gel) to the laboratory results in the least possible artificial increase in potassium concentration in the sample.

  18. Stress corrosion testing of irradiated cladding tubes

    International Nuclear Information System (INIS)

    Lunde, L.; Olshausen, K.D.

    1980-01-01

    Samples from two fuel rods with different cladding have been stress corrosion tested by closed-end argon-iodine pressurization at 320 0 C. The fuel rods with stress relieved and recrystallized Zircaloy-2 had received burnups of 10.000 and 20.000 MWd/ton UO 2 , respectively. It was found that the SCC failure stress was unchanged or slightly higher for the irradiated than for the unirradiated control tubes. The tubes failed consistently in the end with the lowest irradiation dose. The diameter increase of the irradiated cladding during the test was 1.1% for the stress-relieved samples and 0.24% for the recrystallized samples. SEM examination revealed no major differences between irradiated and unirradiated cladding. A ''semi-ductile'' fracture zone in recrystallized material is described in some detail. (author)

  19. 13 CFR 120.651 - Claim to FTA by Registered Holder to replace Certificate.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Claim to FTA by Registered Holder to replace Certificate. 120.651 Section 120.651 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Secondary Market Miscellaneous Provisions § 120.651 Claim to FTA by Registered...

  20. Fatigue behavior of highly porous titanium produced by powder metallurgy with temporary space holders.

    Science.gov (United States)

    Özbilen, Sedat; Liebert, Daniela; Beck, Tilmann; Bram, Martin

    2016-03-01

    Porous titanium cylinders were produced with a constant amount of temporary space holder (70 vol.%). Different interstitial contents were achieved by varying the starting powders (HDH vs. gas atomized) and manufacturing method (cold compaction without organic binders vs. warm compaction of MIM feedstocks). Interstitial contents (O, C, and N) as a function of manufacturing were measured by chemical analysis. Samples contained 0.34-0.58 wt.% oxygen, which was found to have the greatest effect on mechanical properties. Quasi-static mechanical tests under compression at low strain rate were used for reference and to define parameters for cyclic compression tests. Not unexpectedly, increased oxygen content increased the yield strength of the porous titanium. Cyclic compression fatigue tests were conducted using sinusoidal loading in a servo-hydraulic testing machine. Increased oxygen content was concomitant with embrittlement of the titanium matrix, resulting in significant reduction of compression cycles before failure. For samples with 0.34 wt.% oxygen, R, σ(min) and σ(max) were varied systematically to estimate the fatigue limit (~4 million cycles). Microstructural changes induced by cyclic loading were then characterized by optical microscopy, SEM and EBSD. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. RIA simulation tests using driver tube for ATF cladding

    Energy Technology Data Exchange (ETDEWEB)

    Cinbiz, Mahmut N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Brown, N. R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Lowden, R. R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Linton, K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Terrani, K. A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-07-01

    Pellet-cladding mechanical interaction (PCMI) is a potential failure mechanism for accident-tolerant fuel (ATF) cladding candidates during a reactivity-initiated accident (RIA). This report summarizes Fiscal Year (FY) 2017 research activities that were undertaken to evaluate the PCMI-like hoop-strain-driven mechanical response of ATF cladding candidates. To achieve various RIA-like conditions, a modified-burst test (MBT) device was developed to produce different mechanical pulses. The calibration of the MBT instrument was accomplished by performing mechanical tests on unirradiated Generation-I iron-chromium-aluminum (FeCrAl) alloy samples. Shakedown tests were also conducted in both FY 2016 and FY 2017 using unirradiated hydrided ZIRLO™ tube samples. This milestone report focuses on testing of ATF materials, but the benchmark tests with hydrided ZIRLO™ tube samples are documented in a recent journal article.a For the calibration and benchmark tests, the hoop strain was monitored using strain gauges attached to the sample surface in the hoop direction. A novel digital image correlation (DIC) system composed of a single high-speed camera and an array of six mirrors was developed for the MBT instrument to better resolve the failure behavior of samples and to provide useful data for validation of high-fidelity modeling and simulation tools. The DIC system enable a 360° view of a sample’s outer surface. This feature was added to the instrument to determine the precise failure location on a sample’s surface for strain predictions. The DIC system was tested on several silicon carbide fiber/silicon carbide matrix (SiC/SiC) composite tube samples at various pressurization rates of the driver tube (which correspond to the strain rates for the samples). The hoop strains for various loading conditions were determined for the SiC/SiC composite tube samples. Future work is planned to enhance understanding of the failure behavior of the ATF cladding candidates of age

  2. Prototype vibration measurement program for reactor internals (177-fuel assembly plant). Supplement 1

    International Nuclear Information System (INIS)

    Simonis, J.C.; Post, R.C.; Thoren, D.E.

    1976-08-01

    The surveillance specimen holder tubes installed in the Babcock and Wilcox 177-fuel assembly plants have been redesigned. The structural adequacy of this design has been verified through extensive analysis. The design adequacy will be further confirmed by measuring the vibrational response of the surveillance specimen holder tube during normal and transient flow operation. This report describes the vibration measurement program that will be conducted at Toledo Edison's Davis Besse 1 site

  3. Incorrect order of draw could be mitigate the patient safety: a phlebotomy management case report

    Science.gov (United States)

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Picheth, Geraldo; Guidi, Gian Cesare

    2013-01-01

    Procedures involving phlebotomy are critical for obtaining diagnostic blood specimens and represent a well known and recognized problem, probably among the most important issues in laboratory medicine. The aim of this report is to show spurious hyperkalemia and hypocalcemia due to inadequate phlebotomy procedure. The diagnostic blood specimens were collected from a male outpatient 45 years old, with no clinical complaints. The tubes drawing order were as follows: i) clot activator and gel separator (serum vacuum tube), ii) K3EDTA, iii) a needleless blood gas dedicated-syringe with 80 I.U. lithium heparin, directly connected to the vacuum tube holder system. The laboratory testing results from serum vacuum tube and dedicated syringe were 4.8 and 8.5 mmol/L for potassium, 2.36 and 1.48 mmol/L for total calcium, respectively. Moreover 0.15 mmol/L of free calcium was observed in dedicated syringe. A new blood collection was performed without K3EDTA tube. Different results were found for potassium (4.7 and 4.5 mmol/L) and total calcium (2.37 and 2.38 mmol/L) from serum vacuum tube and dedicated syringe, respectively. Also free calcium showed different concentration (1.21 mmol/L) in this new sample when compared with the first blood specimen. Based on this case we do not encourage the laboratory managers training the phlebotomists to insert the dedicated syringes in needle-holder system at the end of all vacuum tubes. To avoid double vein puncture the dedicated syringe for free calcium determination should be inserted immediately after serum tubes before EDTA vacuum tubes. PMID:23894868

  4. 12 CFR 611.1210 - Advance notices-commencement resolution and notice to equity holders.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Advance notices-commencement resolution and notice to equity holders. 611.1210 Section 611.1210 Banks and Banking FARM CREDIT ADMINISTRATION FARM..., within 10 days of adopting the commencement resolution, your bank and the other Farm Credit banks must...

  5. Electron emission of cathode holder of vacuum diode of an intense electron-beam accelerator and its effect on the output voltage

    Directory of Open Access Journals (Sweden)

    Xin-Bing Cheng

    2011-04-01

    Full Text Available The vacuum diode which is used to generate relativistic electron beams is one of the most important parts of a pulsed-power modulator. In this paper, the electron emission of cathode holder of a vacuum diode and its effect on the output voltage is investigated by experiments on an intense electron-beam accelerator with 180 ns full width at half maximum and 200–500 kV output voltage. First, the field emission is analyzed and the electric field of the vacuum chamber is calculated. Then, the flatness of the output voltage is discussed before and after adding an insulation plate when a water load is used. It is found that the electron emission at the edges of the cathode holder is the main reason to cause the change of the flatness. Last, a piece of polyester film is used as a target to further show the electron emission of the cathode holder. This analysis shows that decreasing the electron emission of the cathode holder in such a pulse power modulator could be a good way to improve the quality of the output voltage.

  6. Design and construction of a holder to the safety handling of Cs-137 to be used in cervix cancer treatments using intracavitary brachytherapy by afterloading

    International Nuclear Information System (INIS)

    Gonzales, E.; Lea, D.

    1996-01-01

    In venezuelan public hospitals where cervix cancer treatments are performed by means of Cs-137 manual afterloading systems, the handling of the sources is done with two type of holders, metallic and plastic, the plastic holders are pieces of induced serious radio-sanitary problem such as loser of the Cs-137 source and radioactive contamination in the treatment area, this has caused the interruption of the treatments in many hospitals. This interruption had a high social cost because of the thousands women waiting for intracavitary therapy. To start again with the treatments, the metallic holders were required but there were not enough funds in the budget, because of this problem in a short time IVIS'S health physics drew and made a low price source holder. (authors). 2 figs., 2 tabs

  7. Experimental verification of a deep drawing tool system for adaptive blank holder pressure distribution

    DEFF Research Database (Denmark)

    Tommerup, Søren; Endelt, Benny Ørtoft

    2012-01-01

    In deep drawing, the strain path in the blank during the forming process can be significantly affected by application of temporal and spatial variation of the blank holder force. In this study, an active tool system capable of controlling the distribution of the blank holder force is presented...... which can be integrated into existing stacked deep drawing tools without need for modification of the press. A working system is presented consisting of a controller, designated volume displacement cavity pressure supply units and a shimming plate. It is applied to the deep drawing of a rectangular...... to the conventional shimming method using paper or metal shims between the tool plates. The tool system’s ability to influence the material flow is investigated by performing a series of deep drawing experiments. Eight different cavity pressure schemes are applied during the punch stroke and the scheme’s effects...

  8. Disinfection of Pseudomonas aeruginosa biofilm contaminated tube lumens with ultraviolet C light emitting diodes

    DEFF Research Database (Denmark)

    Bak, Jimmy; Ladefoged, Søren D; Tvede, Michael

    2010-01-01

    with biofilm was investigated. It was shown that UVC light propagation was possible through both Teflon and catheter tubes (silicone). The disinfection efficiency of the diodes was demonstrated on tubes contaminated artificially with a Pseudomonas aeruginosa biofilm. The tubes were connected to a flow system...... and biofilms were produced during a 3 day period. Tubes in lengths of 10 (Teflon, silicone) and 20 cm (Teflon) were contaminated. Tubes for control and for UVC treatment were contaminated in parallel. Biofilms were sampled from the total inner surface of the tubes. Colony counts on the control samples were...... in the range of 5 x 10(5)-1.3 x 10(9) CFU ml(-1), with disinfection rates in the range 96-100%. The applied UVC doses corresponded to treatment times between 15 and 300 min. Disinfection (100%) was obtained in 10 cm Teflon tubes exposed for 30 min (detection limit...

  9. Disinfection of Pseudomonas aeruginosa biofilm contaminated tube lumens with ultraviolet C light emitting diodes

    DEFF Research Database (Denmark)

    Bak, Jimmy; Ladefoged, S.D.; Tvede, M.

    2010-01-01

    with biofilm was investigated. It was shown that UVC light propagation was possible through both Teflon and catheter tubes ( silicone). The disinfection efficiency of the diodes was demonstrated on tubes contaminated artificially with a Pseudomonas aeruginosa biofilm. The tubes were connected to a flow system...... and biofilms were produced during a 3 day period. Tubes in lengths of 10 ( Teflon, silicone) and 20 cm ( Teflon) were contaminated. Tubes for control and for UVC treatment were contaminated in parallel. Biofilms were sampled from the total inner surface of the tubes. Colony counts on the control samples were...... in the range of 5 x 10(5)-1.3 x 10(9) CFU ml(-1), with disinfection rates in the range 96-100%. The applied UVC doses corresponded to treatment times between 15 and 300 min. Disinfection (100%) was obtained in 10 cm Teflon tubes exposed for 30 min (detection limit...

  10. Design and Fabrication of Carbon Nano tube for Medical Application

    International Nuclear Information System (INIS)

    Azniza Abas; Nuzaihan, M.N.; Hafiza, N.; Nazwa, T.

    2011-01-01

    Carbon nano tubes or known as CNTs are allotropes of carbon with a cylindrical nano structure. They exhibit extraordinary strength and unique electrical properties, and are efficient thermal conductors [1]. Due to its ordinary properties this research will based on BIOSENSOR device. Normally these CNTs biosensor are based on an enzyme catalyzed reaction that will produce either electrons or protons. In particular, it is useful in genetic profiling of human diseases, which includes in identifying genes that are expressed in certain diseases such as cancer [2]. This research will based on design and fabricate sensor or device using carbon nano tube and integrate carbon nano tube (CNTs) onto wafer using combination of dichlorophosphate and nano manipulation. Carbon nano tubes device mask are design using AUTOCAD software; there is four mask involved, first mask is Gate Formation,second mask is insulation layer third mask is source and drain and final mask forth mask is used as test channel. For fabrication and optimization of biosensor using carbon nano tube CNT that will be involve both microfabrication and nano fabrication. This process will involve conventional photolithography process, electron beam evaporator, thermal oxidation and wet etching process. To inspect and characterize carbon nano tube electrical properties it will involve tools such as SEM, AFM, Dielectric Analyzer, IV-CV and Semiconductor Parametric Analyzer system. This inspection is very important to produce a perfect profile to produce a good biosensor based on carbon nano tube structure. Preparation of various samples for testing functionality of the device this various samples and conditions will be done to ensure the detection is precise. Conductivity and capacitance effect will be tested electrically to detect the hybridization of the sample. (author)

  11. Tube holding system

    International Nuclear Information System (INIS)

    Cunningham, R.C.

    1978-01-01

    A tube holding rig is described for the lateral support of tubes arranged in tight parcels in a heat exchanger. This tube holding rig includes not less than two tube supporting assemblies, with a space between them, located crosswise with respect to the tubes, each supporting assembly comprising a first set of parallel components in contact with the tubes, whilst a second set of components is also in contact with the tubes. These two sets of parts together define apertures through which the tubes pass [fr

  12. Gene expression differences between PAXgene and Tempus blood RNA tubes are highly reproducible between independent samples and biobanks.

    Science.gov (United States)

    Skogholt, Anne Heidi; Ryeng, Einar; Erlandsen, Sten Even; Skorpen, Frank; Schønberg, Svanhild A; Sætrom, Pål

    2017-03-23

    Gene expression profiling from blood is sensitive to technology choices. For example, the main blood RNA collection systems-the PAXgene and Tempus tubes-differently influence RNA expression signatures. The aim of this study was to establish a common RNA isolation protocol for these two systems and investigate if it could reduce the differences in gene expression between them. We collected identical blood samples on the PAXgene and Tempus systems and retrieved blood samples from two independent biobanks-NOWAC and HUNT3-which are based on PAXgene and Tempus, respectively. High-quality RNA was extracted from both sampling systems by using their original protocols and our common modified protocol, and were profiled on Illumina microarrays. Regardless of the protocol used, we found most of the measured transcripts to be differently affected by the two sampling systems. However, our modified protocol reduced the number of transcripts that were significantly differentially expressed between PAXgene and Tempus by approximately 50%. Expression differences between PAXgene and Tempus were highly reproducible both between protocols and between different independent sample sets (Pearson correlation 0.563-0.854 across 47323 probes). Moreover, the modified protocol increased the microRNA output of the system with lowest microRNA yield, the PAXgene system. Most transcripts are affected by the choice of sampling system, but these effects are highly reproducible between independent samples. We propose that by running a control experiment with samples on both systems in parallel with biologically relevant samples, researchers may adjust for technical differences between the sampling systems.

  13. Effect of fin pitch and number of tube rows on the air side performance of herringbone wavy fin and tube heat exchangers

    International Nuclear Information System (INIS)

    Wongwises, Somchai; Chokeman, Yutasak

    2005-01-01

    An experimental study is conducted to investigate the effects of a fin pitch and number of tube rows on the air side performance of fin and tube heat exchangers having herringbone wavy fin configuration at various fin thicknesses. A total of 10 samples of fin and tube heat exchanger with a tube outside diameter of 9.53mm, transverse tube pitch of 25.4mm and longitudinal tube pitch of 19.05mm, having various fin pitches, number of tube rows and fin thicknesses, are tested in a well insulated open wind tunnel. The heat exchangers are made from aluminium plate finned, copper tube. Ambient air is used as a working fluid in the air side while hot water is used for the tube side. The results are presented as the variation of the Colburn factor and the friction factor with the Reynolds number based on the fin collar outside diameter (Re D c ). The experimental results reveal that the fin pitch has an insignificant effect on the heat transfer characteristic. The friction factor increases with increasing fin pitch when Re D c >2500, approximately. The Colburn factor and the friction factor decrease with increasing number of tube rows when Re D c <4000, approximately. These results remain the same when the fin thickness is changed

  14. HF electronic tubes. Technologies, grid tubes and klystrons

    International Nuclear Information System (INIS)

    Lemoine, Th.

    2009-01-01

    This article gives an overview of the basic technologies of electronic tubes: cathodes, electronic optics, vacuum and high voltage. Then the grid tubes, klystrons and inductive output tubes (IOT) are introduced. Content: 1 - context and classification; 2 - electronic tube technologies: cathodes, electronic optics, magnetic confinement (linear tubes), periodic permanent magnet (PPM) focussing, collectors, depressed collectors; 3 - vacuum technologies: vacuum quality, surface effects and interaction with electrostatic and RF fields, secondary emission, multipactor effect, thermo-electronic emission; 4 - grid tubes: operation of a triode, tetrodes, dynamic operation and classes of use, 'common grid' and 'common cathode' operation, ranges of utilisation and limitations, operation of a tetrode on unadjusted load, lifetime of a tetrode, uses of grid tubes; 5 - klystrons: operation, impact of space charge, multi-cavity klystrons, interaction efficiency, extended interaction klystrons, relation between interaction efficiency, perveance and efficiency, ranges of utilization and power limitations, multi-beam klystrons and sheet beam klystrons, operation on unadjusted load, klystron band pass and lifetime, uses; 6 - IOT: principle of operation, ranges of utilisation and limitations, interaction efficiency and depressed collector IOT, IOT lifetime and uses. (J.S.)

  15. Groundwater sampling from shallow boreholes (PP and PR) and groundwater observation tubes (PVP) at Olkiluoto in 2004

    Energy Technology Data Exchange (ETDEWEB)

    Hirvonen, H. [Teollisuuden Voima Oyj, Eurajoki (Finland)

    2005-11-15

    Groundwater sampling from the shallow boreholes and groundwater observation tubes was performed in summer 2004 (PP2, PP3, PP7, PP8, PRl, PVPl, PVP3A, PVP3B, PVP4A and PVP4B) and in autumn 2004 (PP2, PP3, PP5, PP7, PP8, PP9, PP36, PP37, PP39, PR1, PR2, PVP1, PVP3A, PVP3B, PVP4A, PVP8A, PVP9A, PVP9B, PVP10B, PVP11, PVP12, PVP13, PVP14 and PVP20). The results from previous samplings have been used in the hydrogeochemical baseline characterization at Olkiluoto and some of the latest results have also been part of the ONKALO monitoring program. This study contains data on preliminary pumping of the sampling points and pumping for groundwater sampling and chemical analyses in the laboratory. This study also includes comparison with analytical results obtained between 1995-2004. The total dissolved solids (TDS) of groundwater samples were mainly below 1000 mg/L. According to Davis's TDS classification, these waters were fresh waters. The only exception was the water sample from shallow borehole PP7 (1400mg/L and 1450mg/L), which was brackish. Several different groundwater types were observed, but the most common water type was Ca-HCO{sub 3} (five samples). Analytical results from 1995-2003 were compared. During 2001-2003 in groundwater samples from sampling points PVP1, PVP9A and PP7 all measured main parameters changed considerably, but from summer 2003 to autumn 2004 the greatest alterations occurred in PR2, PVP1, PVP3A and PVP3B waters. These changes can be seen in almost all parameters. For other samples only minor changes in results were observed during the reference period. (orig.)

  16. Delayed hydride cracking in irradiated Zr-2.5 % Nb pressure tubes

    International Nuclear Information System (INIS)

    Cirimello, Pablo; Coronel, Pascual; Haddad, Roberto; Lafont, Claudio; Mizrahi, Rafael

    2003-01-01

    Pressure tubes in CANDU nuclear power plants are made of Zr-2.5 % Nb alloy, which is susceptible to a cracking process called Delayed Hydride Cracking (DHC). Measurement of DHC velocity on irradiated pressure tubes is essential to assure the validity of the Leak Before Break criterion. This work was performed on samples from two pressure tubes taken out of the Embalse NPP in 1995, belonging to fuel channels A-14 and L-12. DHC velocity in the axial direction was measured at 211 C degrees for samples taken from different axial positions, which allowed to study its dependence on fast neutron fluency and irradiation temperature. Non-irradiated material was also tested. It was found that DHC velocity results for the tested material were similar to those obtained for a great number of tubes irradiated in other CANDU plants. (author)

  17. Extending laboratory automation to the wards: effect of an innovative pneumatic tube system on diagnostic samples and transport time.

    Science.gov (United States)

    Suchsland, Juliane; Winter, Theresa; Greiser, Anne; Streichert, Thomas; Otto, Benjamin; Mayerle, Julia; Runge, Sören; Kallner, Anders; Nauck, Matthias; Petersmann, Astrid

    2017-02-01

    The innovative pneumatic tube system (iPTS) transports one sample at a time without the use of cartridges and allows rapid sending of samples directly into the bulk loader of a laboratory automation system (LAS). We investigated effects of the iPTS on samples and turn-around time (TAT). During transport, a mini data logger recorded the accelerations in three dimensions and reported them in arbitrary area under the curve (AUC) units. In addition representative quantities of clinical chemistry, hematology and coagulation were measured and compared in 20 blood sample pairs transported by iPTS and courier. Samples transported by iPTS were brought to the laboratory (300 m) within 30 s without adverse effects on the samples. The information retrieved from the data logger showed a median AUC of 7 and 310 arbitrary units for courier and iPTS transport, respectively. This is considerably below the reported limit for noticeable hemolysis of 500 arbitrary units. iPTS reduces TAT by reducing the hands-on time and a fast transport. No differences in the measurement results were found for any of the investigated 36 analytes between courier and iPTS transport. Based on these findings the iPTS was cleared for clinical use in our hospital.

  18. The research on the failure regularity of GM counter tubes

    International Nuclear Information System (INIS)

    Li Jiyuan; Huai Guangli; Xie Bo; Zhang Hao

    2002-01-01

    The reliability of GM counter tubes should be described by useful time before failure-life and failure rate during life. A new method to study the failure regularity of GM counter tubes is advanced and adopted. The essential point of the method is that after the GM counter tubes of the instruments in use is tested, both the performance parameters and other information of the GM counter tubes and the instruments collected are recorded. Then database is created. Failure criterion is ascertained. The GM counter tubes are inspected to determine whether they are failure. Failure mode should be decided if the GM counter tubes failure. The GM counter tubes with the same useful year come together to make up a subsample. According to the relevant information, the number of the subsample is restored to the number of the sample that initially put into use. Then the number of failure sample is counted and at the same time the distribution of failure mode is got. The parameter m, γ, t 0 of Weibull distribution function are calculated with method of linear fit. Thus mean life, failure rate and other character values are obtained. Using this method, useful life and failure rate are determined. The conclusion is that the useful life is 18-20 years and the failure rate is 5 x 10 -6 and 4 x 10 -6 /h respectively during the course

  19. Smart Farming: Including Rights Holders for Responsible Agricultural Innovation

    Directory of Open Access Journals (Sweden)

    Kelly Bronson

    2018-02-01

    Full Text Available This article draws on the literature of responsible innovation to suggest concrete processes for including rights holders in the “smart” agricultural revolution. It first draws upon historical agricultural research in Canada to highlight how productivist values drove seed innovations with particular consequences for the distribution of power in the food system. Next, the article uses document analysis to suggest that a similar value framework is motivating public investment in smart farming innovations. The article is of interest to smart farming’s decision makers (from farmers to governance actors and a broader audience – anyone interested in engendering equity through innovation-led societal transitions.

  20. Tube to tube excursive instability - sensitivities and transients

    International Nuclear Information System (INIS)

    Brown, M.; Layland, M.W.

    1980-01-01

    A simple basic analysis of excursive instability in a boiler tube shows how it depends upon operating conditions and physical properties. A detailed mathematical model of an AGR boiler is used to conduct a steady state parameter sensitivity survey. It is possible from this basis to anticipate the effects of changes in operating conditions and changes in design parameters upon tube to tube stability. Dynamic responses of tubes operating near the stability threshold are examined using a mathematical model. Simulated excursions are triggered by imparting small abrupt pressure changes on the boiler inlet pressure. The influences of the magnitude of the pressure change, waterside friction factor and gas side coupling between tubes are examined. (author)

  1. Tube-support response to tube-denting evaluation. Volume 1. Final report

    International Nuclear Information System (INIS)

    Anderson, P.L.; Hall, J.F.; Shah, P.K.; Wills, R.L.

    1983-05-01

    The response of the tube supports is one of the important considerations of tube denting in a steam generator. Investigations have indicated that damaged tube supports have the potential to distort and damage tubes. This investigation considers the response to tube denting of the Combustion Engineering type tube supports. Drilled support plates and eggcrate tube supports are tested in a model steam generator in which tube denting is induced. The experimental data is used to verify and refine analytical predictor models developed using finite element techniques. It was found that analytical models underpredicted the deformations of the tube supports and appropriate modifications to enhance the predictive capability are identified. Non-destructive examination methods are evaluated for application to operating steam generators. It was found that the standard eddy current and profilometry techniques are acceptable methods for determining tube deformations, but these techniques are not adequate to assess tube support damage. Radiography is judged to be the best available means of determining the extent and progression of damage in tube supports

  2. Condenser tube buckling within tube-tubesheet joints

    International Nuclear Information System (INIS)

    Willertz, L.E.; Kalnins, A.; Updike, D.P.

    1991-01-01

    The problem of the appearance of protrusions, or bumps, in the interior of roller-expanded tubes within a tubesheet is addressed. Such bumps have been observed in condensers of power plants. A brief history of the reported occurrences of the bumps is given. The hypothesis is advanced that the mechanics of the formation of the bumps is similar to a buckling problem that has 'bifurcation at infinity'. Following this hypothesis, a two-dimensional physical model is developed, and the application of this model to study a three-dimensional bump is proposed. It is proposed in this paper that an initial deviation from the circular shape of the tube required to produce a bump. It is shown that without such a deviation the tubes cannot buckle. An experiment with short tube segments has been performed that verifies some of the features of the observed condenser tube bumps. Exactly what force produced the initial deviation for the observed bumps is still unknown. Available evidence implicates the hydro-laser jet that is used in the cleaning of tubes and tubesheets. A scenario of how a bump could have been produced by the hydro-laser jet is proposed. (author)

  3. Novel sample preparation for operando TEM of catalysts

    International Nuclear Information System (INIS)

    Miller, Benjamin K.; Barker, Trevor M.; Crozier, Peter A.

    2015-01-01

    A new TEM sample preparation method is developed to facilitate operando TEM of gas phase catalysis. A porous Pyrex-fiber pellet TEM sample was produced, allowing a comparatively large amount of catalyst to be loaded into a standard Gatan furnace-type tantalum heating holder. The increased amount of catalyst present inside the environmental TEM allows quantitative determination of the gas phase products of a catalytic reaction performed in-situ at elevated temperatures. The product gas concentration was monitored using both electron energy loss spectroscopy (EELS) and residual gas analysis (RGA). Imaging of catalyst particles dispersed over the pellet at atomic resolution is challenging, due to charging of the insulating glass fibers. To overcome this limitation, a metal grid is placed into the holder in addition to the pellet, allowing catalyst particles dispersed over the grid to be imaged, while particles in the pellet, which are assumed to experience identical conditions, contribute to the overall catalytic conversion inside the environmental TEM cell. The gas within the cell is determined to be well-mixed, making this assumption reasonable. - Highlights: • High in-situ conversion of CO to CO 2 achieved by a novel TEM sample preparation method. • A 3 mm fiber pellet increases the TEM sample surface area by 50×. • Operando atomic resolution is maintained by also including a 3 mm grid in the sample. • Evidence for a well-mixed gas composition inside the ETEM cell is given

  4. A simple method for preparing superconducting FeSe pellets without sealing in evacuated silica tubes

    DEFF Research Database (Denmark)

    Grivel, Jean-Claude

    2017-01-01

    Superconducting tetragonal FeSe pellets were made by reacting mixtures of elemental Fe and Se powders in argon atmosphere without sealing in evacuated silica tubes. A simple tube furnace has been used. Although the tube's material consisted of quartz, an alumina tube could be used as well. X......-ray pure samples with onset of superconducting transition between 8.0K and 8.5K were obtained under specific heat treatment conditions. Residual, unreacted Fe particles could be virtually eliminated through prolonged annealing. A key factor for the synthesis of good samples consists in using processing...

  5. Water tubing-related injuries treated in US emergency departments, 1991-2009.

    Science.gov (United States)

    Heinsimer, Kevin R; Nelson, Nicolas G; Roberts, Kristin J; McKenzie, Lara B

    2013-02-01

    The objective was to describe the patterns and mechanisms of water tubing-related injuries treated in U.S. emergency departments. The National Electronic Injury Surveillance System was used to examine cases of water tubing-related injuries. Sample weights were used to calculate national estimates of water tubing-related injuries. Analyses were conducted in 2010. From 1991-2009 an estimated 69,471 injuries were treated in US emergency departments for water tubing-related injuries. The annual number of cases increased 250% over the 19-year study period (P tubing-related injuries differ for children and adults. Research is needed to determine how best to reduce these injuries.

  6. SPECIAL PURPOSE SHOCK TUBE for BLAST ASSESSMENT

    Data.gov (United States)

    Federal Laboratory Consortium — This device is a specially designed shock tube for testing fabric samples in a controlled environment. The device determines the appropriate types of sensors to be...

  7. Design and technology parameters influence on durability for heat exchangers tube to tubesheet joints

    Science.gov (United States)

    Ripeanu, R. G.

    2017-02-01

    The main failures of heat exchangers are: corrosion of tubes and jacket, tubes blockage and failures of tube to tubesheet joints also by corrosion. The most critical zone is tube to tubesheet joints. Depending on types of tube to tubesheet joints, in order to better respect conditions of tension and compression, this paper analyses the tubesheet holes shapes, smooth and with a grove, on corrosion behavior. In the case of welding tubes with tubesheet, welding parameters modify corrosion behavior. Were realized welded joints by three welding regimes and tested at corrosion in two media, tap water and industrial water. Were tested also samples made of smooth tubes, finned tubes and tubes coated with a passive product as applied by a heat exchanger manufacturer. For all samples, the roughness parameters were measured, before and after the corrosion tests. The obtained corrosion rates show that stress values and their distribution along the joint modify the corrosion behavior. The optimum welding parameters were established in order to increase the joint durability. The paper has shown that passive product used is not proper chosen and the technology of obtaining rolled thread pipes diminishes tubes’ durability by increasing the corrosion rate.

  8. A fluid density sensor based on a resonant tube

    International Nuclear Information System (INIS)

    Zhu, Yong; Dao, Dzung Viet; Woodfield, Peter

    2014-01-01

    A fluid density sensor based on resonance frequency change of a metallic tube is presented. The sensor has been developed without using a complex micro-fabrication process. The sensor is able to identify fluid types/contaminations and improve the performance by reducing testing time, decreasing complexity of testing equipment and reducing sample sizes. The sensor can measure the resonance frequency of its own structure and determine the change in resonance frequency due to the subsequent sample inside the tube. Numerical modelling, analytical modelling and physical testing of a prototype sensor showed comparable results for both the magnitude and resonance frequency shift. The modelling results yielded a resonance frequency shift of 200 Hz from 9.87 kHz to 9.67 kHz after the water was filled into the tube. The actual testing illustrated a resonance frequency change of 280 Hz from 9.11 kHz to 8.83 kHz. The ultimate aim of the work is to determine resonance frequencies of desired samples at a level that could detect genetic disease on a cellular level. (paper)

  9. A simple coated-tube assay for alpha-foeto protein for clinical use

    International Nuclear Information System (INIS)

    Dakubu, S.; Ahene, I.S.; Foli, A.K.

    1977-01-01

    A standard method for coating plastic tubes with antiserum has been applied to coat tubes with rabbit antiserum to human alpha-foeto protein. The coated plastic tubes have been used to set up a radioimmunoassay system which is sensitive and convenient for use on the occasional clinical sample. For a successful coated-tube assay, it was found necessary to modify the final incubation mixture from what was suitable in a standard double antibody assay system. (orig.) [de

  10. Online in-tube microextractor coupled with UV-Vis spectrophotometer for bisphenol A detection.

    Science.gov (United States)

    Poorahong, Sujittra; Thammakhet, Chongdee; Thavarungkul, Panote; Kanatharana, Proespichaya

    2013-01-01

    A simple and high extraction efficiency online in-tube microextractor (ITME) was developed for bisphenol A (BPA) detection in water samples. The ITME was fabricated by a stepwise electrodeposition of polyaniline, polyethylene glycol and polydimethylsiloxane composite (CPANI) inside a silico-steel tube. The obtained ITME coupled with UV-Vis detection at 278 nm was investigated. By this method, the extraction and pre-concentration of BPA in water were carried out in a single step. Under optimum conditions, the system provided a linear dynamic range of 0.1 to 100 μM with a limit of detection of 20 nM (S/N ≥3). A single in-tube microextractor had a good stability of more than 60 consecutive injections for 10.0 μM BPA with a relative standard deviation of less than 4%. Moreover, a good tube-to-tube reproducibility and precision were obtained. The system was applied to detect BPA in water samples from six brands of baby bottles and the results showed good agreement with those obtained from the conventional GC-MS method. Acceptable percentage recoveries from the spiked water samples were obtained, ranging from 83-102% for this new method compared with 73-107% for the GC-MS standard method. This new in-tube CPANI microextractor provided an excellent extraction efficiency and a good reproducibility. In addition, it can also be easily applied for the analysis of other polar organic compounds contaminated in water sample.

  11. An optimum source neutron spectrum and holder shape for extra-corporal treatment of liver cancer by BNCT

    International Nuclear Information System (INIS)

    Nievaart, Sander; Moss, Ray; Sauerwein, Wolfgang; Malago, Massimo; Kloosterman, Jan Leen; Hagen, Tim van der; Dam, Hugo van

    2006-01-01

    In extra-corporal treatment of liver cancer by BNCT, it is desired to have an as homogeneous as possible thermal neutron field throughout the organ. Previous work has shown that when using an epithermal neutron beam, the shape of the holder in which the liver is placed is the critical factor. This study develops the notion further as to what is the optimum neutron spectrum to perform such treatments. In the design calculations, when using Monte Carlo techniques, it is shown that when the expected contributions of the source neutrons in every part of the liver is calculated, a linear optimization scheme such as the Simplex method results in a mix of thermal and epithermal source neutrons to get the highest homogeneity for the thermal neutron field. This optimisation method is demonstrated in 3 holder shapes: cuboid, cylindrical and spherical with each 3 volumes of 2, 4 and 6 litres. A 10 cm thick cuboid model, irradiated from both sides gives the highest homogeneity. The spherical (rotating) holder has the lowest homogeneity but the highest contribution of every source neutron to the thermal neutrons in the liver. This can be advantageous when using a relatively small sized neutron beam with a low strength. (author)

  12. Novel Design for Centrifugal Countercurrent Chromatography: II. Studies on Novel Geometries of Zigzag Toroidal Tubing

    Science.gov (United States)

    Yang, Yi; Aisa, Haji Akber; Ito, Yoichiro

    2009-01-01

    The toroidal column using a zigzag pattern has been improved in both retention of the stationary phase and peak resolution. To further improve the retention of stationary phase and peak resolution, a series of novel geometric designs of tubing (plain, mid-clamping, flattened and flat-twisted tubing) was evaluated their performance in CCC. The results showed that the tubing which was flattened vertically against centrifugal force (vert-flattened tubing) produced the best peak resolution among them. Using vert-flattened tubing a series of experiments was performed to study the effects of column capacity and sample size. The results indicated that a 0.25 ml capacity column is ideal for analysis of small amount samples. PMID:20454530

  13. Effect of layerwise structural inhomogeneity on stress- corrosion cracking of steel tubes

    Science.gov (United States)

    Perlovich, Yu A.; Krymskaya, O. A.; Isaenkova, M. G.; Morozov, N. S.; Fesenko, V. A.; Ryakhovskikh, I. V.; Esiev, T. S.

    2016-04-01

    Based on X-ray texture and structure analysis data of the material of main gas pipelines it was shown that the layerwise inhomogeneity of tubes is formed during their manufacturing. The degree of this inhomogeneity affects on the tendency of tubes to stress- corrosion cracking under exploitation. Samples of tubes were cut out from gas pipelines located under various operating conditions. Herewith the study was conducted both for sections with detected stress-corrosion defects and without them. Distributions along tube wall thickness for lattice parameters and half-width of X-ray lines were constructed. Crystallographic texture analysis of external and internal tube layers was also carried out. Obtained data testifies about considerable layerwise inhomogeneity of all samples. Despite the different nature of the texture inhomogeneity of gas pipeline tubes, the more inhomogeneous distribution of texture or structure features causes the increasing of resistance to stress- corrosion. The observed effect can be explained by saturation with interstitial impurities of the surface layer of the hot-rolled sheet and obtained therefrom tube. This results in rising of lattice parameters in the external layer of tube as compared to those in underlying metal. Thus, internal layers have a compressive effect on external layers in the rolling plane that prevents cracks opening at the tube surface. Moreover, the high mutual misorientation of grains within external and internal layers of tube results in the necessity to change the moving crack plane, so that the crack growth can be inhibited when reaching the layer with a modified texture.

  14. Changes in pediatric tracheostomy tubes exposed to home dishwashing.

    Science.gov (United States)

    Smolar, David E; Ho, Brian; Kent, Steven M; Hughes, C Anthony; Mettenburg, Donald; Rueggeberg, Fredrick A; Groves, Michael W

    2017-09-01

    Determine the effects of household dishwashing on Tracheostomy Tube safety. Tracheostomy tubes accumulate biofilms, which may limit their lifespan. Frequent cleaning of the tubes is a method for biofilm prevention. Cleaning practices vary widely. Some families prefer dishwashing of tubes, but its effects are currently unknown. We hypothesize that dishwashing has no significant effect on the physical properties of tracheostomy tubes and can be recommended as a safe way to clean tracheostomy tubes. Twenty 4.0 Shiley™ pediatric tracheostomy tubes were randomly assigned into dishwashed (DW) and non-dishwashed (NDW) groups, 10/group. DW tubes were subjected to 12 wash cycles. Each tube's hardness along with the surface spectra were analyzed to assess for chemical composition changes. Three cannula samples from each group were also randomly assessed with scanning-electron microscopy and scored by blinded examiners to assess for changes in surface heterogeneity. Hardness testing revealed a statistically significant difference (p = 0.0009) between the NDW and the DW group indicating increased fragility in the dishwashed tubes. Spectral analysis revealed loss of plasticizers, indicating decreased flexibility. Blinded electron microscopy scoring revealed increased surface heterogeneity in the DW group (p = 0.00007). A significant decrease in tube hardness and increased surface heterogeneity were found with dishwashing. The spectral analysis demonstrated increasing fragility. We believe these effects could potentially lead to decreased mechanical safety. With increased surface heterogeneity there is a greater potential for biofilm formation. At this time, dishwashing cannot be recommended as a tracheostomy tube cleaning method. Copyright © 2017. Published by Elsevier B.V.

  15. Optimization of Sealed Tube Graphitization Method for Environmental C-14 Studies Using MICADAS

    Energy Technology Data Exchange (ETDEWEB)

    Rinyu, Laszlo, E-mail: rinyu@atomki.hu [Hertelendi Laboratory of Environmental Studies, Institute of Nuclear Research of the Hungarian Academy of Sciences (ATOMKI), H-4026 Debrecen (Hungary); Isotoptech Zrt., H-4025 Debrecen (Hungary); Molnar, Mihaly [Hertelendi Laboratory of Environmental Studies, Institute of Nuclear Research of the Hungarian Academy of Sciences (ATOMKI), H-4026 Debrecen (Hungary); Ion Beam Physics, ETH Zuerich, CH-8093 Zuerich (Switzerland); Major, Istvan [Hertelendi Laboratory of Environmental Studies, Institute of Nuclear Research of the Hungarian Academy of Sciences (ATOMKI), H-4026 Debrecen (Hungary); Nagy, Tamas; Veres, Mihaly [Isotoptech Zrt., H-4025 Debrecen (Hungary); Kimak, Adam [University of Debrecen, H-4032 Debrecen (Hungary); Wacker, Lukas; Synal, Hans-Arno [Ion Beam Physics, ETH Zuerich, CH-8093 Zuerich (Switzerland)

    2013-01-15

    The original sealed tube zinc reduction graphitization process was first developed for rapid low-precision measurements of biomedical tracer samples and later also applied for high precision measurements of not too old samples. In this study we tested the MICADAS (mini radiocarbon dating system [1]) radiocarbon measurements of targets prepared by sealed tube graphitization process. We found the optimal iron catalyst and reagents (TiH{sub 2} and Zn) amount whereby we can reach a relatively low background level, and minimized the overall {delta}{sup 13}C fractionation during the graphitization. Repeated measurements of normalization standards and real samples with known {sup 14}C activities were very well reproduced. Finally, we demonstrated the applicability of the sealed tube graphitization on real environmental samples covering a wide range of {sup 14}C concentrations.

  16. Chest tube insertion

    Science.gov (United States)

    Chest drainage tube insertion; Insertion of tube into chest; Tube thoracostomy; Pericardial drain ... Be careful there are no kinks in your tube. The drainage system should always sit upright and be placed ...

  17. Vibro-impact responses of a tube with tube--baffle interaction

    International Nuclear Information System (INIS)

    Shin, Y.S.; Sass, D.E.; Jendrzejczyk, J.A.

    1978-01-01

    The relatively small, inherent tube-to-baffle hole clearances associated with manufacturing tolerances in heat exchangers affect the vibrational characteristics and the response of the tube. Numerical studies were made to predict the vibro-impact response of a tube with tube-baffle interaction. The finite element method has been employed with a non-linear elastic contact spring-dashpot to model the effect of the relative approach between the tube and the baffle plate. The coupled equations of motion are directly integrated with a proportional system damping represented by a linear combination of mass and stiffness. Lumped mass approach with explicit time integration scheme was found to be a suitable choice for tube-baffle impacting analysis. Fourier analyses indicate that the higher mode contributions to the tube response are significant for strong tube-baffle impacting. The contact damping forces are negligible compared with the contact spring forces. The numerical analysis results are in reasonably good agreement with those of the experiments

  18. Residual indicator bacteria in autosampler tubing: a field and laboratory assessment.

    Science.gov (United States)

    Hathaway, J M; Hunt, W F; Guest, R M; McCarthy, D T

    2014-01-01

    Microbial contamination in surface waters has become a worldwide cause for concern. As efforts are made to reduce this contamination, monitoring is integral to documenting and evaluating water quality improvements. Autosamplers are beneficial in such monitoring efforts, as large data sets can be generated with minimized effort. The extent to which autosamplers can be utilized for microbial monitoring is largely unknown due to concerns over contamination. Strict sterilization regimes for components contacting the water being sampled are difficult, and sometimes logistically implausible, when utilizing autosamplers. Field experimentation showed contamination of fecal coliform in autosamplers to be more of a concern than that of Escherichia coli. Further study in a controlled laboratory environment suggested that tubing configuration has a significant effect on residual E. coli concentrations in sampler tubing. The amount of time that passed since the last sample was collected from a given sampler (antecedent dry weather period - DWP) tubing was also a significant factor. At a DWP of 7 days, little to no contamination was found. Thus, simple protocols such as providing positive drainage of tubing between sample events and programming samplers to include rinses will reduce concerns of contamination in autosamplers.

  19. Optimization of sampling parameters for standardized exhaled breath sampling.

    Science.gov (United States)

    Doran, Sophie; Romano, Andrea; Hanna, George B

    2017-09-05

    The lack of standardization of breath sampling is a major contributing factor to the poor repeatability of results and hence represents a barrier to the adoption of breath tests in clinical practice. On-line and bag breath sampling have advantages but do not suit multicentre clinical studies whereas storage and robust transport are essential for the conduct of wide-scale studies. Several devices have been developed to control sampling parameters and to concentrate volatile organic compounds (VOCs) onto thermal desorption (TD) tubes and subsequently transport those tubes for laboratory analysis. We conducted three experiments to investigate (i) the fraction of breath sampled (whole vs. lower expiratory exhaled breath); (ii) breath sample volume (125, 250, 500 and 1000ml) and (iii) breath sample flow rate (400, 200, 100 and 50 ml/min). The target VOCs were acetone and potential volatile biomarkers for oesophago-gastric cancer belonging to the aldehyde, fatty acids and phenol chemical classes. We also examined the collection execution time and the impact of environmental contamination. The experiments showed that the use of exhaled breath-sampling devices requires the selection of optimum sampling parameters. The increase in sample volume has improved the levels of VOCs detected. However, the influence of the fraction of exhaled breath and the flow rate depends on the target VOCs measured. The concentration of potential volatile biomarkers for oesophago-gastric cancer was not significantly different between the whole and lower airway exhaled breath. While the recovery of phenols and acetone from TD tubes was lower when breath sampling was performed at a higher flow rate, other VOCs were not affected. A dedicated 'clean air supply' overcomes the contamination from ambient air, but the breath collection device itself can be a source of contaminants. In clinical studies using VOCs to diagnose gastro-oesophageal cancer, the optimum parameters are 500mls sample volume

  20. Novel sample preparation for operando TEM of catalysts.

    Science.gov (United States)

    Miller, Benjamin K; Barker, Trevor M; Crozier, Peter A

    2015-09-01

    A new TEM sample preparation method is developed to facilitate operando TEM of gas phase catalysis. A porous Pyrex-fiber pellet TEM sample was produced, allowing a comparatively large amount of catalyst to be loaded into a standard Gatan furnace-type tantalum heating holder. The increased amount of catalyst present inside the environmental TEM allows quantitative determination of the gas phase products of a catalytic reaction performed in-situ at elevated temperatures. The product gas concentration was monitored using both electron energy loss spectroscopy (EELS) and residual gas analysis (RGA). Imaging of catalyst particles dispersed over the pellet at atomic resolution is challenging, due to charging of the insulating glass fibers. To overcome this limitation, a metal grid is placed into the holder in addition to the pellet, allowing catalyst particles dispersed over the grid to be imaged, while particles in the pellet, which are assumed to experience identical conditions, contribute to the overall catalytic conversion inside the environmental TEM cell. The gas within the cell is determined to be well-mixed, making this assumption reasonable. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. SIMS analysis using a new novel sample stage

    International Nuclear Information System (INIS)

    Miwa, Shiro; Nomachi, Ichiro; Kitajima, Hideo

    2006-01-01

    We have developed a novel sample stage for Cameca IMS-series instruments that allows us to adjust the tilt of the sample holder and to vary the height of the sample surface from outside the vacuum chamber. A third function of the stage is the capability to cool sample to -150 deg. C using liquid nitrogen. Using this stage, we can measure line profiles of 10 mm in length without any variation in the secondary ion yields. By moving the sample surface toward the input lens, the primary ion beam is well focused when the energy of the primary ions is reduced. Sample cooling is useful for samples such as organic materials that are easily damaged by primary ions or electrons

  2. SIMS analysis using a new novel sample stage

    Energy Technology Data Exchange (ETDEWEB)

    Miwa, Shiro [Materials Analysis Lab., Sony Corporation, 4-16-1 Okata, Atsugi 243-0021 (Japan)]. E-mail: Shiro.Miwa@jp.sony.com; Nomachi, Ichiro [Materials Analysis Lab., Sony Corporation, 4-16-1 Okata, Atsugi 243-0021 (Japan); Kitajima, Hideo [Nanotechnos Corp., 5-4-30 Nishihashimoto, Sagamihara 229-1131 (Japan)

    2006-07-30

    We have developed a novel sample stage for Cameca IMS-series instruments that allows us to adjust the tilt of the sample holder and to vary the height of the sample surface from outside the vacuum chamber. A third function of the stage is the capability to cool sample to -150 deg. C using liquid nitrogen. Using this stage, we can measure line profiles of 10 mm in length without any variation in the secondary ion yields. By moving the sample surface toward the input lens, the primary ion beam is well focused when the energy of the primary ions is reduced. Sample cooling is useful for samples such as organic materials that are easily damaged by primary ions or electrons.

  3. Stress-Assisted Corrosion in Boiler Tubes

    Energy Technology Data Exchange (ETDEWEB)

    Preet M Singh; Steven J Pawel

    2006-05-27

    A number of industrial boilers, including in the pulp and paper industry, needed to replace their lower furnace tubes or decommission many recovery boilers due to stress-assisted corrosion (SAC) on the waterside of boiler tubes. More than half of the power and recovery boilers that have been inspected reveal SAC damage, which portends significant energy and economic impacts. The goal of this project was to clarify the mechanism of stress-assisted corrosion (SAC) of boiler tubes for the purpose of determining key parameters in its mitigation and control. To accomplish this in-situ strain measurements on boiler tubes were made. Boiler water environment was simulated in the laboratory and effects of water chemistry on SAC initiation and growth were evaluated in terms of industrial operations. Results from this project have shown that the dissolved oxygen is single most important factor in SAC initiation on carbon steel samples. Control of dissolved oxygen can be used to mitigate SAC in industrial boilers. Results have also shown that sharp corrosion fatigue and bulbous SAC cracks have similar mechanism but the morphology is different due to availability of oxygen during boiler shutdown conditions. Results are described in the final technical report.

  4. A TLD reader for wide range in situ dose measurement

    International Nuclear Information System (INIS)

    Deme, S; Apathy, I.; Bodnar, L.; Csoeke, A.; Hejja, I.

    1998-01-01

    A portable thermoluminescent dosemeter reader suitable for reading at the site of exposure is described. The instrument consists of a glass bulb containing the CaSO 4 :Dy thermoluminescent material laminated to the surface of an electrically heated resistive metal plate. The bulb is encapsulated in a cylindrical, pen-like metal holder made of aluminium. A one-wire-port integrated electronic programmable memory chip mounted inside the holder contains the identification code and the individual calibration parameters of the dosemeter. The aperture of the holder is normally covered by a stainless steel tube to protect the bulb from light and mechanical shocks. The tube slips backwards automatically when the dosemeter is inserted into the reader. The system is used by the Hungarian nuclear power plant. (M.D.)

  5. Pressure tube reactor

    International Nuclear Information System (INIS)

    Susuki, Akira; Murata, Shigeto; Minato, Akihiko.

    1993-01-01

    In a pressure tube reactor, a reactor core is constituted by arranging more than two units of a minimum unit combination of a moderator sealing pipe containing a calandria tube having moderators there between and a calandria tube and moderators. The upper header and a lower header of the calandria tank containing moderators are communicated by way of the moderator sealing tube. Further, a gravitationally dropping mechanism is disposed for injecting neutron absorbing liquid to a calandria gas injection portion. A ratio between a moderator volume and a fuel volume is defined as a function of the inner diameter of the moderator sealing tube, the outer diameter of the calandria tube and the diameter of fuel pellets, and has no influence to intervals of a pressure tube lattice. The interval of the pressure tube lattice is enlarged without increasing the size of the pressure tube, to improve production efficiency of the reactor and set a coolant void coefficient more negative, thereby enabling to improve self controllability and safety. Further, the reactor scram can be conducted by injecting neutron absorbing liquid. (N.H.)

  6. CFD modeling of a boiler's tubes rupture

    Energy Technology Data Exchange (ETDEWEB)

    Rahimi, Masoud; Khoshhal, Abbas; Shariati, Seyed Mehdi [Chemical Engineering Department, Faculty of Engineering, Razi University, Kermanshah (Iran)

    2006-12-15

    This paper reports the results of a study on the reason for tubes damage in the superheater Platen section of the 320MW Bisotoun power plant, Iran. The boiler has three types of superheater tubes and the damage occurs in a series of elbows belongs to the long tubes. A three-dimensional modeling was performed using an in-house computational fluid dynamics (CFD) code in order to explore the reason. The code has ability of simultaneous solving of the continuity, the Reynolds-Averaged Navier-Stokes (RANS) equations and employing the turbulence, combustion and radiation models. The whole boiler including; walls, burners, air channels, three types of tubes, etc., was modeled in the real scale. The boiler was meshed into almost 2,000,000 tetrahedral control volumes and the standard k-{epsilon} turbulence model and the Rosseland radiation model were used in the model. The theoretical results showed that the inlet 18.9MPa saturated steam becomes superheated inside the tubes and exit at a pressure of 17.8MPa. The predicted results showed that the temperature of the steam and tube's wall in the long tubes is higher than the short and medium size tubes. In addition, the predicted steam mass flow rate in the long tube was lower than other ones. Therefore, it was concluded that the main reason for the rupture in the long tubes elbow is changing of the tube's metal microstructure due to working in a temperature higher than the design temperature. In addition, the structural fatigue tension makes the last elbow of the long tube more ready for rupture in comparison with the other places. The concluded result was validated by observations from the photomicrograph of the tube's metal samples taken from the damaged and undamaged sections. (author)

  7. Vertical steam generator with slab-type tube-plate with even tube bundle washing

    International Nuclear Information System (INIS)

    Manek, O.; Masek, V.; Motejl, V.; Quitta, R.

    1980-01-01

    A shielding plate supporting the tubes attached to the tube plate of a vertical steam generator is mounted above the tube plate. Tube sleeves are designed with a dimensional tolerance relative to the heat transfer tubes and the sleeve end and the tube plate end. A separate space is thus formed above the tube plate in which circulation or feed water is introduced to flow between the branch and the heat transfer tube. This provides intensive washing of heat transfer tubes at a critical point and prevents deposit formation, thus excluding heat transfer tube failures. (J.B.)

  8. Nuclear Forensic Lab Interoperability and Criminal Investigation

    Science.gov (United States)

    2014-08-01

    to the decay-corrected disintegrations per second (Bq) from the certified specific activity and the aliquot mass. Count rates for each peak were...balance, five- place • Anti-static holder for plastic bottles • Anti-static “gun” or equivalent Bottles for reagents Teflon or HDPE Test tubes...for GPEC wash solutions plastic Vials or bottles for sample collection Teflon or HDPE (or other non-leachable plastic ) Pipets, pipet tips

  9. Raising awareness about protection and control of nuclear materials held by 'small-scale holders'

    International Nuclear Information System (INIS)

    Ladsous, D.; Coulie, E.; Giorgio, M.

    2013-01-01

    In France, the activities carried out by the 'small-scale holders' of nuclear materials are organized by a specific regulatory system which defines in a detailed way their obligations and the means of control of the government. The first part of the article presents the legal framework relating to the use of nuclear materials by small-scale holders in civilian fields. The importance of the declaration of the nuclear material inventory is clearly emphasized and must be prepared and transmitted to the Institute for Radiological Protection and Nuclear Safety (IRSN) every year. The second part describes how this declaration is used to provide basic information for the competent Ministry and the inspectors to check the correct application of the regulatory requirements relating to physical protection and to the control of nuclear materials. Finally, the last part presents the on-site inspections carried out by sworn and accredited inspectors under the authority of the competent Authority, which provide an overall picture and allow an evaluation of the risks of theft, loss or diversion of these materials. (authors)

  10. Impact of the Flame-Holder Heat-Transfer Characteristics on the Onset of Combustion Instability

    KAUST Repository

    Hong, Seunghyuck

    2013-10-03

    In this article, we investigate the impact of heat transfer between the flame and the flameholder on the dynamic stability characteristics of a 50-kW backward-facing step combustor. We conducted a series of tests where two backward step blocks were used, made of ceramic and stainless steel, whose thermal conductivities are 1.06 and 12 W/m/K, respectively. Stability characteristics of the two flame-holder materials were examined using measurements of the dynamic pressure and flame chemiluminescence over a range of operating conditions. Results show that with the ceramic flameholder, the onset of instability is significantly delayed in time and, for certain operating conditions, disappears altogether, whereas with the higher conductivity material, the combustor becomes increasingly unstable over a range of operating conditions. We explain these trends using the heat flux through the flameholder and the change in the burning velocity near the step wall. Results suggest a potential approach using low-thermal-conductivity material near the flame-holder as passive dynamics suppression methods. Copyright © Taylor & Francis Group, LLC.

  11. Head holder using negative pressure bag packed with plastic beads in xenon CT CBF study

    International Nuclear Information System (INIS)

    Araki, Yuzo; Sakai, Noboru

    2003-01-01

    Employing analysis of cerebral blood flow (CBF) confidence maps, we investigated the usefulness of a head holder using a negative pressure bag packed with plastic beads in a xenon CT CBF study. A total of 272 consecutive patients for the CBF study were enrolled and classified into 3 groups: 88 patients with a negative pressure bag (M group), 87 patients with an air pillow (A group), and 97 patients with a sponge pillow (S group). The degree of effect of head movements on the CBF measurement in each patient was expressed as a confidence value (mean of the confidence values at one CT slice). The mean of confidence value in the M group (0.461) was statistically lower than that in the A group (0.866) and that in the S group (1.043). These findings showed that the head holder described here was useful for obtaining CBF maps of high quality in a xenon CT CBF study. (author)

  12. Compounded Apixaban Suspensions for Enteral Feeding Tubes.

    Science.gov (United States)

    Caraballo, Maria L; Donmez, Seda; Nathan, Kobi; Zhao, Fang

    2017-07-01

    Objective: There is limited information on compounded apixaban formulations for administration via enteral feeding tubes. This study was designed to identify a suitable apixaban suspension formulation that is easy to prepare in a pharmacy setting, is compatible with commonly used feeding tubes, and has a beyond-use date of 7 days. Methods: Apixaban suspensions were prepared from commercially available 5-mg Eliquis tablets. Several vehicles and compounding methods were screened for ease of preparation, dosage accuracy, and tube compatibility. Two tubing types, polyurethane and polyvinyl chloride, with varying lengths and diameters, were included in the study. They were mounted on a peg board during evaluation to mimic the patient body position. A 7-day stability study of the selected formulation was also conducted. Results: Vehicles containing 40% to 60% Ora-Plus in water all exhibited satisfactory flowability through the tubes. The mortar/pestle compounding method was found to produce more accurate and consistent apixaban suspensions than the pill crusher or crushing syringe method. The selected formulation, 0.25 mg/mL apixaban in 50:50 Ora-Plus:water, was compatible with both tubing types, retaining >98% drug in posttube samples. The stability study also confirmed that this formulation was stable physically and chemically over 7 days of storage at room temperature. Conclusions: A suitable apixaban suspension formulation was identified for administration via enteral feeding tubes. The formulation consisted of 0.25 mg/mL apixaban in 50:50 Ora-Plus:water. The stability study results supported a beyond-use date of 7 days at room temperature.

  13. Flow-through immunomagnetic separation system for waterborne pathogen isolation and detection: Application to Giardia and Cryptosporidium cell isolation

    Energy Technology Data Exchange (ETDEWEB)

    Ramadan, Qasem, E-mail: qasem.alramadan@epfl.ch [Bioelectronics Program, Institute of Microelectronics, 11 Science Park Road, Singapore 117685 (Singapore); Christophe, Lay; Teo, William; ShuJun, Li; Hua, Feng Han [Bioelectronics Program, Institute of Microelectronics, 11 Science Park Road, Singapore 117685 (Singapore)

    2010-07-12

    Simultaneous sample washing and concentration of two waterborne pathogen samples were demonstrated using a rotational magnetic system under continuous flow conditions. The rotation of periodically arranged small permanent magnets close to a fluidic channel carrying magnetic particle suspension allows the trapping and release of particles along the fluidic channel in a periodic manner. Each trapping and release event resembles one washing cycle. The performance of the magnetic separation system (MSS) was evaluated in order to test its functionality to isolate magnetic-labelled protozoan cells from filtered, concentrated tap water, secondary effluent water, and purified water. Experimental protocols described in US Environmental Protection Agency method 1623 which rely on the use of a magnetic particle concentrator, were applied to test and compare our continuous flow cell separation system to the standard magnetic bead-based isolation instruments. The recovery efficiencies for Giardia cysts using the magnetic tube holder and our magnetic separation system were 90.5% and 90.1%, respectively, from a tap water matrix and about 31% and 18.5%, respectively, from a spiked secondary effluent matrix. The recovery efficiencies for Cryptosporidium cells using the magnetic tube holder and our magnetic separation system were 90% and 83.3%, respectively, from a tap water matrix and about 38% and 36%, respectively, from a spiked secondary effluent matrix. Recoveries from all matrices with the continuous flow system were typically higher in glass tubing conduits than in molded plastic conduits.

  14. Ceramic waste form qualification using results from witness tubes

    International Nuclear Information System (INIS)

    O'Holleran, T.P.; Johnson, S.G.; Bateman, K.J.

    2002-01-01

    A ceramic waste form has been developed to immobilize the salt waste stream from electrometallurgical treatment of spent nuclear fuel. The ceramic waste form is prepared in a hot isostatic press (HIP). The use of small, easily fabricated HIP capsules called witness tubes has been proposed as a practical way to obtain representative samples of ceramic waste form material for process monitoring, waste form qualification, and archiving. Witness tubes are filled with the same material used to fill the corresponding HIP can, and are HIPed along with the HIP can. Relevant physical, chemical, and performance (leach test) data are analyzed and compared. Differences between witness tube and HIP can materials are shown to be statistically insignificant, demonstrating that witness tubes do provide ceramic waste form material representative of the material in the corresponding HIP can.

  15. Use of CATHENA to model calandria-tube/moderator heat transfer after pressure-tube/calandria-tube ballooning contact

    International Nuclear Information System (INIS)

    Fan, H.Z.; Bilanovic, Z.; Nitheanandan, T.

    2004-01-01

    A study was performed to assess the effect of the calandria-tube/moderator heat transfer after pressure-tube/calandria tube ballooning contact using CATHENA. Results of this study indicated that the analytical tool, CATHENA, can be applied for pool boiling heat transfer on the external surface of a large diameter tube, such as the calandria tube used in CANDU reactors. The methodology in such CANDU-generic study can be used to simulate the tube surface with multiple boiling regimes and to assess the benefits of closely coupling thermalhydraulics modelling and fuel/fuel channel behaviour modelling. CATHENA (Canadian Algorithm for THErmalhydraulic Network Analysis) is a one-dimensional, two-fluid thermalhydraulic simulation code designed by AECL to analyse two-phase flow and heat transfer in piping networks. The detailed heat transfer package in CATHENA allows a connection to be established from the multiple solid surfaces of tubes to the surrounding large amount of moderator water, which acts as a heat sink during a postulated loss of coolant event. The generalized heat transfer package within CATHENA allows the tube walls to be divided into several layers in the radial direction and several sectors in the circumferential direction, to account for heat transfer conditions in these two directions. The CATHENA code with the generalized heat transfer package is capable of capturing key pool-boiling phenomena such as nucleate, transition and film boiling heat transfer as well as an ability to model the rewet phenomenon to some extent. A CATHENA input model was generated and used in simulations of selected contact boiling experiment test cases. The transient wall temperatures have been calculated in different portions of the calandria tube. By using this model an adequate agreement was achieved between CATHENA calculation and experimental measurement The CATHENA code enables one to investigate the transient and local thermal-mechanical behaviour of the calandria tube

  16. Biocide-mediated corrosion of coiled tubing.

    Science.gov (United States)

    Sharma, Mohita; An, Dongshan; Liu, Tao; Pinnock, Tijan; Cheng, Frank; Voordouw, Gerrit

    2017-01-01

    Coiled tubing corrosion was investigated for 16 field water samples (S5 to S20) from a Canadian shale gas field. Weight loss corrosion rates of carbon steel beads incubated with these field water samples averaged 0.2 mm/yr, but injection water sample S19 had 1.25±0.07 mm/yr. S19 had a most probable number of zero acid-producing bacteria and incubation of S19 with carbon steel beads or coupons did not lead to big changes in microbial community composition. In contrast other field water samples had most probable numbers of APB of 102/mL to 107/mL and incubation of these field water samples with carbon steel beads or coupons often gave large changes in microbial community composition. HPLC analysis indicated that all field water samples had elevated concentrations of bromide (average 1.6 mM), which may be derived from bronopol, which was used as a biocide. S19 had the highest bromide concentration (4.2 mM) and was the only water sample with a high concentration of active bronopol (13.8 mM, 2760 ppm). Corrosion rates increased linearly with bronopol concentration, as determined by weight loss of carbon steel beads, for experiments with S19, with filtered S19 and with bronopol dissolved in defined medium. This indicated that the high corrosion rate found for S19 was due to its high bronopol concentration. The corrosion rate of coiled tubing coupons also increased linearly with bronopol concentration as determined by electrochemical methods. Profilometry measurements also showed formation of multiple pits on the surface of coiled tubing coupon with an average pit depth of 60 μm after 1 week of incubation with 1 mM bronopol. At the recommended dosage of 100 ppm the corrosiveness of bronopol towards carbon steel beads was modest (0.011 mm/yr). Higher concentrations, resulting if biocide is added repeatedly as commonly done in shale gas operations, are more corrosive and should be avoided. Overdosing may be avoided by assaying the presence of residual biocide by HPLC

  17. Improvement of pump tubes for gas guns and shock tube drivers

    Science.gov (United States)

    Bogdanoff, D. W.

    1990-01-01

    In a pump tube, a gas is mechanically compressed, producing very high pressures and sound speeds. The intensely heated gas produced in such a tube can be used to drive light gas guns and shock tubes. Three concepts are presented that have the potential to allow substantial reductions in the size and mass of the pump tube to be achieved. The first concept involves the use of one or more diaphragms in the pump tube, thus replacing a single compression process by multiple, successive compressions. The second concept involves a radical reduction in the length-to-diameter ratio of the pump tube and the pump tube piston. The third concept involves shock heating of the working gas by high explosives in a cyclindrical geometry reusable device. Preliminary design analyses are performed on all three concepts and they appear to be quite feasible. Reductions in the length and mass of the pump tube by factors up to about 11 and about 7, respectively, are predicted, relative to a benchmark conventional pump tube.

  18. Measured thermal and fast neutron fluence rates for ATF-1 holders during ATR cycle 160A

    International Nuclear Information System (INIS)

    Walker, B. J.; Miller, D. T.

    2017-01-01

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 160A which were measured by the Radiation Measurements Laboratory (RML).

  19. Measured thermal and fast neutron fluence rates for ATF-1 holders during ATR cycle 160A

    Energy Technology Data Exchange (ETDEWEB)

    Walker, B. J. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Miller, D. T. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-06-06

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 160A which were measured by the Radiation Measurements Laboratory (RML).

  20. Study of tritium permeation through Peach Bottom Steam Generator tubes

    International Nuclear Information System (INIS)

    Yang, L.; Baugh, W.A.; Baldwin, N.L.

    1977-06-01

    The report describes the equipment developed, samples tested, procedures used, and results obtained in the tritium permeation tests conducted on steam generator tubing samples which were removed from the Peach Bottom Unit No. 1 reactor

  1. Benchmarking sample preparation/digestion protocols reveals tube-gel being a fast and repeatable method for quantitative proteomics.

    Science.gov (United States)

    Muller, Leslie; Fornecker, Luc; Van Dorsselaer, Alain; Cianférani, Sarah; Carapito, Christine

    2016-12-01

    Sample preparation, typically by in-solution or in-gel approaches, has a strong influence on the accuracy and robustness of quantitative proteomics workflows. The major benefit of in-gel procedures is their compatibility with detergents (such as SDS) for protein solubilization. However, SDS-PAGE is a time-consuming approach. Tube-gel (TG) preparation circumvents this drawback as it involves directly trapping the sample in a polyacrylamide gel matrix without electrophoresis. We report here the first global label-free quantitative comparison between TG, stacking gel (SG), and basic liquid digestion (LD). A series of UPS1 standard mixtures (at 0.5, 1, 2.5, 5, 10, and 25 fmol) were spiked in a complex yeast lysate background. TG preparation allowed more yeast proteins to be identified than did the SG and LD approaches, with mean numbers of 1979, 1788, and 1323 proteins identified, respectively. Furthermore, the TG method proved equivalent to SG and superior to LD in terms of the repeatability of the subsequent experiments, with mean CV for yeast protein label-free quantifications of 7, 9, and 10%. Finally, known variant UPS1 proteins were successfully detected in the TG-prepared sample within a complex background with high sensitivity. All the data from this study are accessible on ProteomeXchange (PXD003841). © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Vibro-impact responses of a tube with tube--baffle interaction. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Y S; Sass, D E; Jendrzejczyk, J A

    1978-01-01

    The relatively small, inherent tube-to-baffle hole clearances associated with manufacturing tolerances in heat exchangers affect the vibrational characteristics and the response of the tube. Numerical studies were made to predict the vibro-impact response of a tube with tube-baffle interaction. The finite element method has been employed with a non-linear elastic contact spring-dashpot to model the effect of the relative approach between the tube and the baffle plate. The coupled equations of motion are directly integrated with a proportional system damping represented by a linear combination of mass and stiffness. Lumped mass approach with explicit time integration scheme was found to be a suitable choice for tube-baffle impacting analysis. Fourier analyses indicate that the higher mode contributions to the tube response are significant for strong tube-baffle impacting. The contact damping forces are negligible compared with the contact spring forces. The numerical analysis results are in reasonably good agreement with those of the experiments.

  3. 42 CFR 60.43 - Limitation, suspension, or termination of the eligibility of a HEAL lender or holder.

    Science.gov (United States)

    2010-10-01

    ... notice, sent by certified mail, specifying his or her intention to terminate the lender or holder's... that a HEAL lender fails to meet the statutory definition of an “eligible lender.” (d) This section...

  4. Continuous 'Passive' Registration of Non-Point Contaminant Loads Via Agricultural Subsurface Drain Tubes

    Science.gov (United States)

    Rozemeijer, J.; Jansen, S.; de Jonge, H.; Lindblad Vendelboe, A.

    2014-12-01

    Considering their crucial role in water and solute transport, enhanced monitoring and modeling of agricultural subsurface tube drain systems is important for adequate water quality management. For example, previous work in lowland agricultural catchments has shown that subsurface tube drain effluent contributed up to 80% of the annual discharge and 90-92% of the annual NO3 loads from agricultural fields towards the surface water. However, existing monitoring techniques for flow and contaminant loads from tube drains are expensive and labor-intensive. Therefore, despite the unambiguous relevance of this transport route, tube drain monitoring data are scarce. The presented study aimed developing a cheap, simple, and robust method to monitor loads from tube drains. We are now ready to introduce the Flowcap that can be attached to the outlet of tube drains and is capable of registering total flow, contaminant loads, and flow-averaged concentrations. The Flowcap builds on the existing SorbiCells, a modern passive sampling technique that measures average concentrations over longer periods of time (days to months) for various substances. By mounting SorbiCells in our Flowcap, a flow-proportional part of the drain effluent is sampled from the main stream. Laboratory testing yielded good linear relations (R-squared of 0.98) between drainage flow rates and sampling rates. The Flowcap was tested in practice for measuring NO3 loads from two agricultural fields and one glasshouse in the Netherlands. The Flowcap registers contaminant loads from tube drains without any need for housing, electricity, or maintenance. This enables large-scale monitoring of non-point contaminant loads via tube drains, which would facilitate the improvement of contaminant transport models and would yield valuable information for the selection and evaluation of mitigation options to improve water quality.

  5. Bender/Coiler for Tubing

    Science.gov (United States)

    Stoltzfus, J. M.

    1983-01-01

    Easy-to-use tool makes coils of tubing. Tubing to be bend clamped with stop post. Die positioned snugly against tubing. Operator turns handle to slide die along tubing, pushing tubing into spiral groove on mandrel.

  6. Sensitivity of the improved Dutch tube diffusion test for detection of ...

    African Journals Online (AJOL)

    The sensitivity of the improved two-tube test for detection of antimicrobial residues in Kenyan milk was investigated by comparison with the commercial Delvo test SP. Suspect positive milk samples (n =244) from five milk collection centers, were analyzed with the improved two-tube and the commercial Delvo SP test as per ...

  7. Running Mechanics and Metabolic Responses with Water Bottles and Bottle Belt Holders.

    Science.gov (United States)

    Vincent, Heather K; Zdziarski, Laura A; Fallgatter, Kyle; Negron, Giorgio; Chen, Cong; Leavitt, Trevor; Horodyski, MaryBeth; Wasser, Joseph G; Vincent, Kevin R

    2018-01-18

    This study determined whether differential kinematics, kinetics, rates of energy use and cardiopulmonary responses occurred during running with water bottles and bottle belt holders compared to running only. Trained runners (N=42; 27.2±6.4 yr) ran on an instrumented treadmill for four conditions in a randomized order: 1) control run (CON); 2) hand-held full water bottle (FULL, 16.9 fluid oz; 454 g); 3) hand-held half-full water bottle (HALF, 8.4 fluid oz.; 227 g); and 4) waist-worn bottle belt holder (BELT; hydration belt; 676 g). Gas exchange was measured using a portable gas analyzer. Kinetic and kinematic responses were determined via standard 3D videographic techniques. Interactions of limb side (right, left) by study condition (CON, FULL, HALF, BELT) were tested for rates of oxygen use and energy expenditure, and kinematic and kinetic parameters. No significant limb side × condition interactions existed for rates of oxygen use or energy expenditure. A significant interaction occurred with sagittal elbow flexion (pwater by hand or on the waist does not significantly change kinematics of running motion, rates of oxygen use and energy expenditure or cardiopulmonary measures over short durations. Runners are likely making adjustments to joint moments and powers that preserve balance and protect the lower extremity joints while maintaining the rates of oxygen use and energy expenditure.

  8. Salvaging of service exposed cast alloy 625 cracker tubes of ammonia based Heavy Water Plants

    International Nuclear Information System (INIS)

    Kumar, Niraj; Misra, B.; Mahajan, M.P.; Mittra, J.; Sundararaman, M.; Chakravartty, J.K.

    2006-01-01

    In ammonia based heavy water plants, cracking of ammonia vapour, enriched in deuterium is carried out inside a cracker tube, packed with catalyst. These cracker tubes are made of alloy 625 (either wrought or cast) having dimensions of about 12.5 metres long, 88 mm outer diameter and 7.9 mm wall thickness. Seventy such tubes are housed in a typical ammonia cracker unit. The anticipated design life of such tube is 1,00,000 hrs. when operated at 720 degC based on creep as main degradation mechanism. Presently, these tubes are being operated at 680 degC skin temperature. Alloy 625 tubes are costly and normally not manufactured in India and are being imported. The cast alloy 625 cracker tubes have outlived their design life of 100,000 hrs. Therefore it has been decided to salvage the cast cracker tubes and extend the life further as it had already been done for wrought tubes. Similar to the earlier attempt of resolutionising of wrought alloy 625 tubes, efforts are in progress to salvage these cast tubes. In this study, cast tubes samples were subjected to solution-annealing treatment at two different temperatures, 1100degC and 1160degC respectively for two hrs. Mechanical properties along with the microstructure of the samples, which were resolutionized at 1160degC were comparable with that of virgin material. The 12.5 metres long cast alloy 625 cracker tubes will also be shortly solution-annealed in a specially designed resistance heating furnace after completing some more tests. (author)

  9. Steam generator tube extraction

    International Nuclear Information System (INIS)

    Delorme, H.

    1985-05-01

    To enable tube examination on steam generators in service, Framatome has now developed a process for removing sections of steam generator tubes. Tube sections can be removed without being damaged for treating the tube section expanded in the tube sheet

  10. Quick Detection of Contaminants Leaching from Polypropylene Centrifuge Tube with Surface Enhanced Raman Spectroscopy and Ultra Violet Absorption Spectroscopy

    OpenAIRE

    Xu, Zhida; Liu, Logan

    2014-01-01

    Anomalous surface enhanced Raman scattering (SERS) peaks are identified for liquid sample stored in polypropylene centrifuge tubes (PP tube) for months. We observed the unexpected Raman peaks during experiments for Thiamine Hydrochloride aqueous solution stored in PP tube for two months. In order to identify the contaminants we have performed SERS experiments for de-ionized water (DI water) stored in polypropylene centrifuge tube for two months and compared them with fresh DI water sample. We...

  11. Naval Reserve Force: Cost and Benefit Analysis of Reducing the Number of Naval Surface Reserve Force Operating Budget Holders

    National Research Council Canada - National Science Library

    Young, Eric

    1997-01-01

    .... This thesis examines one of Commander Naval Surface Reserve Force's initiatives for reducing the current number of Operating Budget holder's Comptroller Departments without sacrificing efficiency...

  12. The biofilm-controlling functions of rechargeable antimicrobial N-halamine dental unit waterline tubing.

    Science.gov (United States)

    Porteous, Nuala; Schoolfield, John; Luo, Jie; Sun, Yuyu

    2011-01-01

    A study was conducted to test the biofilm-controlling functions of N-halamine tubing over an eight-month period. A laboratory system, simulating a teaching dental clinic, was used to test rechargeable N-halamine tubing (T) compared to an untreated control (C) using the unit manufacturer's tubing. For the long-term study, a recharged tubing (RC) treated with bleach was used to compare with the test (T) and the control (C) tubing. Source tap water was cycled through the lines at 1.4 mL/minute, five minutes on and 25 minutes off, eight hours/day, five days/week. Every three weeks, samples of effluent, recovered adherent bacteria from inside tubing surfaces, and SEM images were examined for bacterial and biofilm growth. After sampling, a recharging solution of chlorine bleach (1 : 10 dilution) was run through T and RC lines, left overnight, and rinsed out the next morning. One-way ANOVAs and Spearman correlations were performed to detect significant differences for T, RC, and C, and determine significance with time period and source water, respectively. Mean log CFU/mL for C effluent > T (p = 0.028), and C tubing > T (p = 0.035). Spearman correlations were significant between effluent and source water level for T (rho = 0.817), and T tubing (0.750); between RC tubing and source water level (rho = 0.836), and time (rho = 0.745); and between C and time (rho = 0.873). SEM imaging confirmed the presence of biofilm inside RC and C, but not inside T. N-halamine tubing completely inhibited biofilm formation without negatively affecting the physical properties of the effluent water. Further research on N-halamine tubing using a pure water source is recommended, as T effluent bacterial levels reflected the source tap water quality and proliferation of planktonic bacteria with no biofilm activity.

  13. The Two-Year College as a First Choice, Second Chance Institution for Baccalaureate-Degree Holders

    Science.gov (United States)

    Townsend, Barbara K.

    2009-01-01

    This study focused on degree-seeking baccalaureate-degree holders at one two-year technical institute in the Midsouth to determine why they chose to study at the two-year college and how they compared their two-year college experience with their baccalaureate educational experience. Findings indicated the technical college was their first choice…

  14. The influence of tube voltage and phantom size in computed tomography on the dose-response relationship of dicentrics in human blood samples

    International Nuclear Information System (INIS)

    Jost, G; Pietsch, H; Lengsfeld, P; Voth, M; Schmid, E

    2010-01-01

    The aim of this study was to investigate the dose response relationship of dicentrics in human lymphocytes after CT scans at tube voltages of 80 and 140 kV. Blood samples from a healthy donor placed in tissue equivalent abdomen phantoms of standard, pediatric and adipose sizes were exposed at dose levels up to 0.1 Gy using a 64-slice CT scanner. It was found that both the tube voltage and the phantom size significantly influenced the CT scan-induced linear dose-response relationship of dicentrics in human lymphocytes. Using the same phantom (standard abdomen), 80 kV CT x-rays were biologically more effective than 140 kV CT x-rays. However, it could also be determined that the applied phantom size had much more influence on the biological effectiveness. Obviously, the increasing slopes of the CT scan-induced dose response relationships of dicentrics in human lymphocytes obtained in a pediatric, a standard and an adipose abdomen have been induced by scattering effects of photons, which strongly increase with increasing phantom size.

  15. The influence of tube voltage and phantom size in computed tomography on the dose-response relationship of dicentrics in human blood samples

    Energy Technology Data Exchange (ETDEWEB)

    Jost, G; Pietsch, H [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Lengsfeld, P; Voth, M [Global Medical Affairs Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Schmid, E, E-mail: Ernst.Schmid@lrz.uni-muenchen.d [Institute for Cell Biology, Center for Integrated Protein Science, University of Munich (Germany)

    2010-06-07

    The aim of this study was to investigate the dose response relationship of dicentrics in human lymphocytes after CT scans at tube voltages of 80 and 140 kV. Blood samples from a healthy donor placed in tissue equivalent abdomen phantoms of standard, pediatric and adipose sizes were exposed at dose levels up to 0.1 Gy using a 64-slice CT scanner. It was found that both the tube voltage and the phantom size significantly influenced the CT scan-induced linear dose-response relationship of dicentrics in human lymphocytes. Using the same phantom (standard abdomen), 80 kV CT x-rays were biologically more effective than 140 kV CT x-rays. However, it could also be determined that the applied phantom size had much more influence on the biological effectiveness. Obviously, the increasing slopes of the CT scan-induced dose response relationships of dicentrics in human lymphocytes obtained in a pediatric, a standard and an adipose abdomen have been induced by scattering effects of photons, which strongly increase with increasing phantom size.

  16. Evaluation of single and double centrifugation tube methods for concentrating equine platelets.

    Science.gov (United States)

    Argüelles, D; Carmona, J U; Pastor, J; Iborra, A; Viñals, L; Martínez, P; Bach, E; Prades, M

    2006-10-01

    The aim of this study was to evaluate single and double centrifugation tube methods for concentrating equine platelets. Whole blood samples were collected from clinically normal horses and processed by use of single and double centrifugation tube methods to obtain four platelet concentrates (PCs): PC-A, PC-B, PC-C, and PC-D, which were analyzed using a flow cytometry hematology system for hemogram and additional platelet parameters (mean platelet volume, platelet distribution width, mean platelet component concentration, mean platelet component distribution width). Concentrations of transforming growth factor beta 1 (TGF-beta(1)) were determined in all the samples. Platelet concentrations for PC-A, PC-B, PC-C, and PC-D were 45%, 44%, 71%, and 21% higher, respectively, compared to the same values for citrated whole blood samples. TGF-beta(1) concentrations for PC-A, PC-B, PC-C, and PC-D were 38%, 44%, 44%, and 37% higher, respectively, compared to citrated whole blood sample values. In conclusion, the single and double centrifugation tube methods are reliable methods for concentrating equine platelets and for obtaining potentially therapeutic TGF-beta(1) levels.

  17. Feeding tube - infants

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007235.htm Feeding tube - infants To use the sharing features on this page, please enable JavaScript. A feeding tube is a small, soft, plastic tube placed ...

  18. SMART Tubing Presents an Increased Risk of Disconnection During Extracorporeal Circulation

    Science.gov (United States)

    Newling, Ross; Morris, Richard

    2005-01-01

    Abstract: A number of products exhibiting biocompatible features have been developed for use in extracorporeal blood circuits during cardiopulmonary bypass procedures. While attention has been focused on biocompatibility features of the blood-circuit interface, a number of issues applicable in clinical use of these circuits have arisen. Surface Modifying Additive Technology (SMART; Cobe Cardiovascular, Arvarda, CO) is one such technology. In this product, the structure of normal polyvinylchloride (PVC) tubing is altered through the blending of two copolymers to give a more biocompatible blood to plastic interface. In this study, we examined the in vitro mechanical ability of random samples (n = 10) of SMART and standard PVC tubing to withstand axial tension when the tubing was placed over a single barb of a connector. The tension required to remove the SMART tubing from the connector (83.3 ± 7.3 [SD] N), was significantly less than standard PVC tubing (115.6 ± 15.9 N; p tubing exhibited a 28% reduction in tubing to connector adhesion, which may have a significant effect on extracorporeal circuit disconnection and overall patient safety. PMID:16524161

  19. Ecological Diversity of Soil Fauna as Ecosystem Engineers in Small-Holder Cocoa Plantation in South Konawe

    Directory of Open Access Journals (Sweden)

    Laode Muhammad Harjoni Kilowasid

    2012-05-01

    Full Text Available Taxa diversity within soil fauna functional groups can affected ecosystem functioning such as ecosystem engineers,which influence decomposition and nutrient cycling. The objective of this study is to describe ecological diversityvariation within soil fauna as ecosystem engineers in soil ecosystem of cocoa (Theobroma cacao L. plantation.Sampling was conducted during one year period from five different ages of plantation. Soil fauna removed from soilcore using hand sorting methods. A total of 39 genera of soil fauna as ecosystem engineers were found during thesestudies. Thirty five genera belong to the group of Formicidae (ants, three genera of Isoptera (termites, and onegenera of Oligochaeta (earthworms. Ecological diversity variation within ecosystem engineers was detected withSimpson indices for dominance and evenness. The highest diversity of ecosystem engineers was in the young ageof plantation. This study reinforces the importance biotic interaction which contributed to the distribution andabundance within soil fauna community as ecosystem engineers in small-holder cocoa plantation.

  20. A Modeling approach for analysis and improvement of spindle-holder-tool assembly dynamics

    OpenAIRE

    Budak, Erhan; Ertürk, A.; Erturk, A.; Özgüven, H. N.; Ozguven, H. N.

    2006-01-01

    The most important information required for chatter stability analysis is the dynamics of the involved structures, i.e. the frequency response functions (FRFs) which are usually determined experimentally. In this study, the tool point FRF of a spindle-holder-tool assembly is analytically determined by using the receptance coupling and structural modification techniques. Timoshenko’s beam model is used for increased accuracy. The spindle is also modeled analytically with elastic supports repre...

  1. Adhesion of volatile propofol to breathing circuit tubing.

    Science.gov (United States)

    Lorenz, Dominik; Maurer, Felix; Trautner, Katharina; Fink, Tobias; Hüppe, Tobias; Sessler, Daniel I; Baumbach, Jörg Ingo; Volk, Thomas; Kreuer, Sascha

    2017-08-21

    Propofol in exhaled breath can be measured and may provide a real-time estimate of plasma concentration. However, propofol is absorbed in plastic tubing, thus estimates may fail to reflect lung/blood concentration if expired gas is not extracted directly from the endotracheal tube. We evaluated exhaled propofol in five ventilated ICU patients who were sedated with propofol. Exhaled propofol was measured once per minute using ion mobility spectrometry. Exhaled air was sampled directly from the endotracheal tube and at the ventilator end of the expiratory side of the anesthetic circuit. The circuit was disconnected from the patient and propofol was washed out with a separate clean ventilator. Propofol molecules, which discharged from the expiratory portion of the breathing circuit, were measured for up to 60 h. We also determined whether propofol passes through the plastic of breathing circuits. A total of 984 data pairs (presented as median values, with 95% confidence interval), consisting of both concentrations were collected. The concentration of propofol sampled near the patient was always substantially higher, at 10.4 [10.25-10.55] versus 5.73 [5.66-5.88] ppb (p tubing was 4.58 [4.48-4.68] ppb, 3.46 [3.21-3.73] in the first hour, 4.05 [3.77-4.34] in the second hour, and 4.01 [3.36-4.40] in the third hour. Out-gassing propofol from the breathing circuit remained at 2.8 ppb after 60 h of washing out. Diffusion through the plastic was not observed. Volatile propofol binds or adsorbs to the plastic of a breathing circuit with saturation kinetics. The bond is reversible so propofol can be washed out from the plastic. Our data confirm earlier findings that accurate measurements of volatile propofol require exhaled air to be sampled as close as possible to the patient.

  2. Plasma immersion ion implantation (and deposition) inside metallic tubes of different dimensions and configurations

    Science.gov (United States)

    Ueda, M.; Silva, C.; Santos, N. M.; Souza, G. B.

    2017-10-01

    There is a strong need for developing methods to coat or implant ions inside metallic tubes for many practical contemporary applications, both for industry and science. Therefore, stainless steel tubes with practical diameters of 4, 11 and 16 cm, but short lengths of 20 cm, were internally treated by nitrogen plasma immersion ion implantation (PIII). Different configurations as tube with lid in one of the ends or both sides open were tested for better PIII performance, in the case of smallest diameter tube. Among these PIII tests in tubes, using the 4 cm diameter one with a lid, it was possible to achieve tube temperatures of more than 700 °C in 15 min and maintain it during the whole treatment time (typically 2 h). Samples made of different materials were placed at the interior of the tube, as the monitors for posterior analysis, and the tube was solely pulsed by high voltage pulser producing high voltage glow discharge and hollow cathode discharge both driven by a moderate power source. In this experiment, samples of SS 304, pure Ti, Ti6Al4V and Si were used for the tests of the above methods. Results on the analysis of the surface of these nitrogen PIII treated materials, as well as on their processing methods, are presented and discussed in the paper.

  3. Non-contact Measurement of Remaining Thickness of Corroding Superheater Tubes. Phase 1

    Energy Technology Data Exchange (ETDEWEB)

    Borggreen, Kjeld; Storesund, Jan

    2006-10-15

    Corrosion of superheaters has become a severe problem in many biomass boilers and incineration plants. This new situation calls for frequent tube wall thickness testing of the superheaters during very short shut-downs. To meet this demand Electro Magnetic Acoustic Transducer (EMAT) candidates as substitute for conventional manually operated contact UT-transducers. The EMAT can contactlessly generate an ultrasonic wave in the interphase between the external oxide and the metal. This means that measurements can be undertaken much quicker and with a much higher coverage simultaneously, without preceding blast operations. It is the aim of the project to demonstrate the usefulness of two simple EMAT systems, Panametrics and Sonatest, for fast and reliable tube thickness inspections in difficult-to-access superheater sections. The present Phase 1 of the project involves testing of the performance of the two systems in laboratory with the following results: 1. Both instruments work well on plate, tube, and pipe samples assuming the presence of an external oxide layer formed at a temperature above approximately 400 deg C. 2. Both instruments work well on all types of ferritic and martensitic steels but not on austenitic steels. 3. Both instruments work well independent of the thickness of the active oxide layer. 4. Both instruments work well independent of tube diameter, wall thickness, and sample width. 5. Both instruments work well over a very large range of wall thicknesses. Minimum tube wall thickness is less than 1.8 mm. 6. The tolerable lift-off (free distance between transducer and tube surface) is 2.4 - 3.0 mm for Panametrics system and 3.6 - 4.8 mm for Sonatest's system. The tolerable lift-off is a measure of the thickness of ash deposits, which can be tolerated on the tube surface as well as the misplacement, which can be tolerated in case of remote tube testing. 7. The tolerable off-set between tube axis and probe axis is very large for both instruments (10

  4. A programmable air sampler with adsorption tubes

    International Nuclear Information System (INIS)

    Riesing, J.; Roetzer, H.; Hick, H.

    1997-01-01

    The Air Sampler AS3 was utilized for the European Tracer Experiment (ETEX) to measure the concentrations of the perfluorocarbon tracers. At thirty-two sampling points these devices were placed to collect the tracer substances in adsorption tubes for subsequent laboratory analysis in the Environment Institute of the JRC Ispra. The Air Sampler is also suitable for monitoring the environment, particularly of industrial emitters or landfills, by sampling of volatile substances. The Air Sampler AS3 is a portable, user-friendly instrument due to light weight, ruggedness and reliable operation. It is capable of fully automatic sampling of air and gas with 24 adsorption tubes and program-controlled gas flow. Collection times can be programmed freely between 1 sec and 8 days and waiting times between 1 sec and 30 days. Programming is possible via keyboard, memory card or serial interface. A protocol of sampling control data is stored on a memory card giving documentation of sampling conditions. On the memory card there is space for the storage of 10 sampling programs and 10 sets of sampling control data. Before the start of ETEX the AS3 was used in a measurement campaign to measure the background concentrations of the perfluorocarbon tracers in Austria. In the provinces of Upper Austria and Salzburg the Air Sampler is used by the departments for environmental protection for the monitoring of BTX-concentrations in air. (author)

  5. Monetizing a Meme: YouTube, Content ID, and the Harlem Shake

    Directory of Open Access Journals (Sweden)

    Michael Soha

    2016-01-01

    Full Text Available This article analyzes the creation, evolution, and monetization of the Harlem Shake meme on YouTube to explore contemporary implementation of copyright and understanding of authorship in regard to monetization of works with distributed authorship. This article has three main findings: first, we highlight the collection of digital labor that comprises the “Harlem Shake” meme, its rise in popularity, and the subsequent rise in popularity of Baauer, the composer of the song which forms the backbone of the meme; second, we examine how YouTube’s “new bargain” of Content ID, as a departure from the site’s origins creates coercive control mechanisms, shedding new light on the concept of and debate over “digital sharecropping.” Finally, we argue for a “Fair(er use” system by exploring how memes might be understood outside of the contemporary copyright system, rethinking the rights of users engaged in collective production. The article is significant in that it challenges the current distribution of Content ID payments solely to copyright holders in an attempt to rethink a system that acknowledges the creative labor of memetic phenomena and collective authorship.

  6. Eustachian tube patency

    Science.gov (United States)

    Eustachian tube patency refers to how much the eustachian tube is open. The eustachian tube runs between the middle ear and the throat. It controls the pressure behind the eardrum and middle ear space. This helps keep ...

  7. Effect of tube-support interaction on the dynamic responses of heat exchanger tubes

    International Nuclear Information System (INIS)

    Shin, Y.S.; Jendrzejczyk, J.A.; Wambsganss, M.W.

    1977-01-01

    Operating heat exchangers have experienced tube damages due to excessive flow-induced vibration. The relatively small inherent tube-to-baffle hole clearances associated with manufacturing tolerances in heat exchangers affect the tube vibrational characteristics. In attempting a theoretical analysis, questions arise as to the effects of tube-baffle impacting on dynamic responses. Experiments were performed to determine the effects of tube-baffle impacting in vertical/horizontal tube orientation, and in air/water medium on the vibrational characteristics (resonant frequencies, mode shapes, and damping) and displacement response amplitudes of a seven-span tube model. The tube and support conditions were prototypic, and overall length approximately one-third that of a straight tube segment of the steam generator designed for the CRBR. The test results were compared with the analytical results based on the multispan beam with ''knife-edge'' supports

  8. Description of a double centrifugation tube method for concentrating canine platelets.

    Science.gov (United States)

    Perazzi, Anna; Busetto, Roberto; Martinello, Tiziana; Drigo, Michele; Pasotto, Daniela; Cian, Francesco; Patruno, Marco; Iacopetti, Ilaria

    2013-07-22

    To evaluate the efficiency of platelet-rich plasma preparations by means of a double centrifugation tube method to obtain platelet-rich canine plasma at a concentration at least 4 times higher than the baseline value and a concentration of white blood cells not exceeding twice the reference range. A complete blood count was carried out for each sample and each concentrate. Whole blood samples were collected from 12 clinically healthy dogs (consenting blood donors). Blood was processed by a double centrifugation tube method to obtain platelet concentrates, which were then analyzed by a flow cytometry haematology system for haemogram. Platelet concentration and white blood cell count were determined in all samples. Platelet concentration at least 4 times higher than the baseline value and a white blood cell count not exceeding twice the reference range were obtained respectively in 10 cases out of 12 (83.3%) and 11 cases out of 12 (91.6%). This double centrifugation tube method is a relatively simple and inexpensive method for obtaining platelet-rich canine plasma, potentially available for therapeutic use to improve the healing process.

  9. Annular gap measurement between pressure tube and calandria tube by eddy current technique

    International Nuclear Information System (INIS)

    Bhole, V.M.; Rastogi, P.K.; Kulkarni, P.G.

    1992-01-01

    In pressurised heavy water reactor (PHWR) major distinguishing feature is that there are number of identical fuel channels in the reactor core. Each channel consists of pressure tube of Zr-2.5 Nb or zircaloy-2 through which high temperature, high pressure primary coolant is passing. The pressure tube contains fuel. Surrounding the pressure tube there is low pressure, cool heavy water (moderator). The moderator is thermally separated from coolant by the tube which is nominally concentric with pressure tube called calandria tube. There are four garter springs in the annular gap between pressure tube and calandria tube. During the life of the reactor there are number of factors by which the pressure tube sags, most important factors are irradiation creep, thermal creep, fuel load etc. Because of the sag of pressure tube it can touch the calandria tube resulting in formation of cold spot. This leads to hydrogen concentration at that spot by which the material at that place becomes brittle and can lead to catastrophic failure of pressure tube. There is no useful access for measurement of annular gap either through the gas annular space or from exterior of calandria tube. So the annular gap was measured from inside surface of pressure tube which is accessible. Eddy current technique was used for finding the gap. The paper describe the details of split coil design of bobbin probe, selection of operating point on normalised impedance diagram by choosing frequency. Experimental results on full scale mock up, and actual gap measurement in reactor channel, are also given. (author). 7 figs

  10. Categorising YouTube

    DEFF Research Database (Denmark)

    Simonsen, Thomas Mosebo

    2011-01-01

    This article provides a genre analytical approach to creating a typology of the User Generated Content (UGC) of YouTube. The article investigates the construction of navigation processes on the YouTube website. It suggests a pragmatic genre approach that is expanded through a focus on YouTube......’s technological affordances. Through an analysis of the different pragmatic contexts of YouTube, it is argued that a taxonomic understanding of YouTube must be analysed in regards to the vacillation of a user-driven bottom-up folksonomy and a hierarchical browsing system that emphasises a culture of competition...... and which favours the already popular content of YouTube. With this taxonomic approach, the UGC videos are registered and analysed in terms of empirically based observations. The article identifies various UGC categories and their principal characteristics. Furthermore, general tendencies of the UGC within...

  11. An investigation on compression strength analysis of commercial aluminium tube to aluminium 2025 tube plate by using TIG welding process

    Energy Technology Data Exchange (ETDEWEB)

    Kannan, S., E-mail: kannan.dgl201127@gmail.com [Department of Mechanical Engineering and Mining Machinery Engineering, Indian Institute of Technology (ISM), Dhanbad, Jharkhand, India, 826004 (India); Senthil Kumaran, S., E-mail: sskumaran@ymail.com [Research and Development Center, Department of Mechanical Engineering, RVS Educational Trust' s Group of Institutions, RVS School of Engineering and Technology, Dindigul, Tamilnadu, India, 624005 (India); Kumaraswamidhas, L.A., E-mail: lakdhas1978@gmail.com [Department of Mechanical Engineering and Mining Machinery Engineering, Indian School of Mines University, Dhanbad, Jharkhand, India, 826004 (India)

    2016-05-05

    In this present study, Tungsten inert gas (TIG) welding was applied to weld the dissimilar materials and authenticate the mechanical and metallurgical properties of tube to tube plate made up of commercial aluminium and Al 2025 respectively using an Zirconiated tungsten electrode along with filler material aluminium ER 2219. In total, twenty five pieces has been subjected to compression strength and hardness value to evaluate the optimal joint strength. The three optimization technique has been used in this experiment. Taguchi L{sub 25} orthogonal array is used to identify the most influencing process parameter which affects the joint strength. ANOVA method is measured for both compression strength and hardness to calculate the percentage of contribution for each process parameter. Genetic algorithm is used to validate the results obtained from the both experimental value and optimization value. The micro structural study is depicted the welding joints characterization in between tube to tube plate joints. The radiograph test is conducted to prove the welds are non-defective and no flaws are found during the welding process. The mechanical property of compression strength and hardness has been measured to obtain the optimal joint strength of the welded sample was about 174.846 MPa and 131.364 Hv respectively. - Highlights: • Commercial Al tube and Al 2025 tube plate successfully welded by TIG welding. • Compression strength and hardness value proves to obtain optimal joint strength. • The maximum compression and hardness was achieved in various input parameters.

  12. An investigation on compression strength analysis of commercial aluminium tube to aluminium 2025 tube plate by using TIG welding process

    International Nuclear Information System (INIS)

    Kannan, S.; Senthil Kumaran, S.; Kumaraswamidhas, L.A.

    2016-01-01

    In this present study, Tungsten inert gas (TIG) welding was applied to weld the dissimilar materials and authenticate the mechanical and metallurgical properties of tube to tube plate made up of commercial aluminium and Al 2025 respectively using an Zirconiated tungsten electrode along with filler material aluminium ER 2219. In total, twenty five pieces has been subjected to compression strength and hardness value to evaluate the optimal joint strength. The three optimization technique has been used in this experiment. Taguchi L_2_5 orthogonal array is used to identify the most influencing process parameter which affects the joint strength. ANOVA method is measured for both compression strength and hardness to calculate the percentage of contribution for each process parameter. Genetic algorithm is used to validate the results obtained from the both experimental value and optimization value. The micro structural study is depicted the welding joints characterization in between tube to tube plate joints. The radiograph test is conducted to prove the welds are non-defective and no flaws are found during the welding process. The mechanical property of compression strength and hardness has been measured to obtain the optimal joint strength of the welded sample was about 174.846 MPa and 131.364 Hv respectively. - Highlights: • Commercial Al tube and Al 2025 tube plate successfully welded by TIG welding. • Compression strength and hardness value proves to obtain optimal joint strength. • The maximum compression and hardness was achieved in various input parameters.

  13. Electronic setup for fluorescence emission measurements and long-time constant-temperature maintenance of Single-Walled Carbon Nano-Tubes in water solutions

    Directory of Open Access Journals (Sweden)

    De Rosa Matteo

    2017-03-01

    Full Text Available In our previous research we have observed that the fluorescence emission from water solutions of Single-Walled Carbon Nano-Tubes (SWCNT, excited by a laser with a wavelength of 830nm, diminishes with the time. We have already proved that such a fading is a function of the storage time and the storage temperature. In order to study the emission of the SWCNT as a function of these two parameters we have designed and realized a special measurement compartment with a cuvette holder where the SWCNT solutions can be measured and stored at a fixed constant temperature for periods of time as long as several weeks. To maintain the measurement setup under a constant temperature we have designed special experimental setup based on two Peltier cells with electronic temperature control.

  14. Pressure tube type reactors

    International Nuclear Information System (INIS)

    Komada, Masaoki.

    1981-01-01

    Purpose: To increase the safety of pressure tube type reactors by providing an additional ECCS system to an ordinary ECCS system and injecting heavy water in the reactor core tank into pressure tubes upon fractures of the tubes. Constitution: Upon fractures of pressure tubes, reduction of the pressure in the fractured tubes to the atmospheric pressure in confirmed and the electromagnetic valve is operated to completely isolate the pressure tubes from the fractured portion. Then, the heavy water in the reactor core tank flows into and spontaneously recycles through the pressure tubes to cool the fuels in the tube to prevent their meltdown. By additionally providing the separate ECCS system to the ordinary ECCS system, fuels can be cooled upon loss of coolant accidents to improve the safety of the reactors. (Moriyama, K.)

  15. Fundamental study on temperature estimation of steam generator tubes at sodium-water reaction

    International Nuclear Information System (INIS)

    Furukawa, Tomohiro; Yoshida, Eiichi

    2008-11-01

    In case of the tube failure in the steam generator of the sodium cooled fast breeder reactor, its adjoined tubes are rapidly heated up by the chemical reaction between sodium and water/steam. And it is known that the tubes have the damage called 'wastage' by the disclosure steam jet. This research is a fundamental study based on the metallography about temperature estimation of the damaged tubes at the sodium-water reaction for the establishment of mechanism analysis technique of the behavior. In the examination, the material which gave the rapid thermal history which imitated sodium-water reaction was produced. And it was investigated whether the thermal history (i.e. maximum temperature and the holding time) of the samples could be presumed from the metallurgical examination of the samples. The major results are as follows: (1) The microstructure of the sample which was given the rapid thermal heating has reserved the influence of the maximum temperature and the time, and the structure can explain by referring to the equilibrium diagram and the continuous cooling transformation diagram. (2) Results of the electrolytic extraction of the samples, the ratio of the remained volume to the electrolyzed volume degreased with the increase of the maximum temperature and the time. Furthermore, it was observed the correlation between the remained volume of each element (Cr, Mo, Fe, V and Nb) and the thermal history. (3) It was obtained that the thermal history of the tubes damaged by sodium-water reaction might be able to be estimated from the metallurgical examinations. (author)

  16. Rotor for processing liquids using movable capillary tubes

    Science.gov (United States)

    Johnson, W.F.; Burtis, C.A.; Walker, W.A.

    1987-07-17

    A rotor assembly for processing liquids, especially whole blood samples, is disclosed. The assembly includes apparatus for separating non-liquid components of whole blood samples from liquid components, apparatus for diluting the separated liquid component with a diluent and apparatus for transferring the diluted sample to an external apparatus for analysis. The rotor assembly employs several movable capillary tubes to handle the sample and diluents. A method for using the rotor assembly to process liquids is also described. 5 figs.

  17. Tube-in-shell heat exchangers

    International Nuclear Information System (INIS)

    Richardson, J.

    1976-01-01

    Tube-in-shell heat exchangers normally comprise a bundle of parallel tubes within a shell container, with a fluid arranged to flow through the tubes in heat exchange with a second fluid flowing through the shell. The tubes are usually end supported by the tube plates that separate the two fluids, and in use the tube attachments to the tube plates and the tube plates can be subject to severe stress by thermal shock and frequent inspection and servicing are required. Where the heat exchangers are immersed in a coolant such as liquid Na such inspection is difficult. In the arrangement described a longitudinally extending central tube is provided incorporating axially spaced cylindrical tube plates to which the opposite ends of the tubes are attached. Within this tube there is a tubular baffle that slidably seals against the wall of the tube between the cylindrical tube plates to define two co-axial flow ducts. These ducts are interconnected at the closed end of the tube by the heat exchange tubes and the baffle comprises inner and outer spaced walls with the interspace containing Ar. The baffle is easily removable and can be withdrawn to enable insertion of equipment for inspecting the wall of the tube and tube attachments and to facilitate plugging of defective tubes. Cylindrical tube plates are believed to be superior for carrying pressure loads and resisting the effects of thermal shock. Some protection against thermal shock can be effected by arranging that the secondary heat exchange fluid is on the tube side, and by providing a thermal baffle to prevent direct impingement of hot primary fluid on to the cylindrical tube plates. The inner wall of the tubular baffle may have flexible expansible region. Some nuclear reactor constructions incorporating such an arrangement are described, including liquid metal reactors. (U.K.)

  18. Heat exchanger tube tool

    International Nuclear Information System (INIS)

    Gugel, G.

    1976-01-01

    Certain types of heat-exchangers have tubes opening through a tube sheet to a manifold having an access opening offset from alignment with the tube ends. A tool for inserting a device, such as for inspection or repair, is provided for use in such instances. The tool is formed by a flexible guide tube insertable through the access opening and having an inner end provided with a connector for connection with the opening of the tube in which the device is to be inserted, and an outer end which remains outside of the chamber, the guide tube having adequate length for this arrangement. A flexible transport hose for internally transporting the device slides inside of the guide tube. This hose is long enough to slide through the guide tube, into the heat-exchanger tube, and through the latter to the extent required for the use of the device. The guide tube must be bent to reach the end of the heat-exchanger tube and the latter may be constructed with a bend, the hose carrying anit-friction elements at interspaced locations along its length to make it possible for the hose to negotiate such bends while sliding to the location where the use of the device is required

  19. Evaluation of the effect of a laparoscopic robotized needle holder on ergonomics and skills.

    Science.gov (United States)

    Bensignor, Thierry; Morel, Guillaume; Reversat, David; Fuks, David; Gayet, Brice

    2016-02-01

    Laparoscopy generates technical and ergonomics difficulties due to limited degrees of freedom (DOF) of forceps. To reduce this limitation, a new 5-mm robotized needle holder with two intracorporeal DOF, Jaimy(®), has been developed. The aim of this study was to evaluate its effects on ergonomics and skills. Fourteen surgeons including eight senior and six residents were crossover randomized and stratified based on experience. Three suturing tasks were performed with both Jaimy(®) and a classic needle holder (NH): task 1: Peg-Board; task 2: hexagonal suture; task 3: frontal suture. Postural ergonomics of the dominant arm were evaluated with an ergonomics score (RULA score) thanks to motion capture, and muscular ergonomics with electromyography of six muscular groups (flexor and extensor carpis, biceps, triceps, deltoid, trapeze). Performance outcomes are a quantitative and qualitative score, and skills outcomes are the measurement of the number of movements and the path length travelled by the instrument. The RULA score showed a statistically improved posture with Jaimy(®) (p < 0.001). The cumulative muscular workload (CMW) of four muscles was not different. However, the CMW was in favor of the NH for the flexor carpi ulnaris (p < 0.001) and the triceps (p = 0.027). The number of movements was not different (p = 0.39) although the path length was shorter with Jaimy(®) (p = 0.012). The score for task 1 was in favor of the NH (p = 0.006) with a higher quantity score. Task 2 score was not different (p = 0.086): The quality part of the score was in favor of Jaimy(®) (p = 0.009) and the quantity part was higher with the NH (p = 0.04). The score for task 3 was higher with Jaimy(®) (p = 0.001). This study suggests that the use of a robotized needle holder improves both posture and the quality of laparoscopic sutures.

  20. Observation of "YouTube" Language Learning Videos ("YouTube" LLVS)

    Science.gov (United States)

    Alhamami, Munassir

    2013-01-01

    This paper navigates into the "YouTube" website as one of the most usable online tools to learn languages these days. The paper focuses on two issues in creating "YouTube" language learning videos: pedagogy and technology. After observing the existing "YouTube" LLVs, the study presents a novel rubric that is directed…

  1. Observations and insights into Pb-assisted stress corrosion cracking of alloy 600 steam generator tubes

    International Nuclear Information System (INIS)

    Thomas, L.; Bruemmer, Stephen M.

    2005-01-01

    Pb-assisted stress-corrosion cracking (PbSCC) of Alloy 600 steam-generator tubing in high-temperature-water service and laboratory tests were studied by analytical transmission electron microscopy of cross-sectioned samples. Examinations of pulled tubes from many pressurized water reactors revealed lead in cracks from 11 of 17 samples. Comparisons of the degraded intergranular structures with ones produced in simple laboratory tests with PbO in near-neutral AVT water showed that the PbSCC characteristics in service tubing could be reproduced without complex chemistries and heat-flow conditions that can occur during plant operation. Observations of intergranular and transgranular cracks promoted by Pb in the test samples also provided new insights into the mechanisms of PbSCC in mill-annealed and thermally treated Alloy 600

  2. Helically coiled tube heat exchanger

    International Nuclear Information System (INIS)

    Harris, A.M.

    1981-01-01

    In a heat exchanger such as a steam generator for a nuclear reactor, two or more bundles of helically coiled tubes are arranged in series with the tubes in each bundle integrally continuing through the tube bundles arranged in series therewith. Pitch values for the tubing in any pair of tube bundles, taken transverse to the path of the reactor coolant flow about the tubes, are selected as a ratio of two unequal integers to permit efficient operation of each tube bundle while maintaining the various tube bundles of the heat exchanger within a compact envelope. Preferably, the helix angle and tube pitch parallel to the path of coolant flow are constant for all tubes in a single bundle so that the tubes are of approximately the same length within each bundle

  3. Categorising YouTube

    OpenAIRE

    Simonsen, Thomas Mosebo

    2011-01-01

    This article provides a genre analytical approach to creating a typology of the User Generated Content (UGC) of YouTube. The article investigates the construction of navigation processes on the YouTube website. It suggests a pragmatic genre approach that is expanded through a focus on YouTube’s technological affordances. Through an analysis of the different pragmatic contexts of YouTube, it is argued that a taxonomic understanding of YouTube must be analysed in regards to the vacillation of a...

  4. Re-examination of demonstration gas discharge tubes

    International Nuclear Information System (INIS)

    Maharaj, H.P.

    1991-01-01

    Gas discharge tubes in which electrons or ions are accelerated at voltages on the order of kilovolts to produce observable atomic effects are potential x-ray sources. These tubes come in various shapes, sizes and designs, and are still in use in science classrooms despite the decline predicted in the 1970s. Because of current applications, a representative sample consisting of fifteen tubes marketed over a recent 2-year period was reexamined for regulatory compliance, product identification and advertising. The results revealed that: poor quality control and design can affect x-ray emissions; and deficiencies exist in product identification, safe use guidelines and operating instructions. This paper reports that these findings, together with the dose estimates, implications and subjective indicators, strongly suggest a user group of unknown size is at increased risk. A combination of enhanced surveillance and promotion of user awareness strategies is adopted to reduce and possible eliminate the potential health risks

  5. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... YouTube Videos » NEI YouTube Videos: Amblyopia Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration ... Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: ...

  6. Effect of Tube Pitch on Pool Boiling Heat Transfer of Vertical Tube Bundle

    International Nuclear Information System (INIS)

    Kang, Myeong Gie

    2016-01-01

    Summarizing the previous results it can be stated that heat transfer coefficients are highly dependent on the tube pitch and the heat flux of the relevant tube. The published results are mostly about the horizontal tubes. However, there are many heat exchangers consisting of vertical tubes like AP600. Therefore, the focus of the present study is an identification of the effects of a tube pitch as well as the heat flux of a relevant tube on the heat transfer of a tube bundle installed vertically. When the heat flux is increased many bubbles are generating due to the increase of the nucleation sites. The bubbles become coalescing with the nearby bubbles and generates big bunches of bubbles on the tube surface. This prevents the access of the liquid to the surface and deteriorates heat transfer. The bubble coalescence is competing with the mechanisms enhancing heat transfer. The pitch was varied from 28.5 mm to 95 mm and the heat flux of the nearby tube was changed from 0 to 90kW/m"2. The enhancement of the heat transfer is clearly observed when the heat flux of the nearby tube becomes larger and the heat flux of the upper tube is less than 40kW/m"2. The effect of the tube pitch on heat transfer is negligible as the value of DP/ is increased more than 4.

  7. Optimizing Tube Precurvature to Enhance Elastic Stability of Concentric Tube Robots.

    Science.gov (United States)

    Ha, Junhyoung; Park, Frank C; Dupont, Pierre E

    2017-02-01

    Robotic instruments based on concentric tube technology are well suited to minimally invasive surgery since they are slender, can navigate inside small cavities and can reach around sensitive tissues by taking on shapes of varying curvature. Elastic instabilities can arise, however, when rotating one precurved tube inside another. In contrast to prior work that considered only tubes of piecewise constant precurvature, we allow precurvature to vary along the tube's arc length. Stability conditions for a planar tube pair are derived and used to formulate an optimal design problem. An analytic formulation of the optimal precurvature function is derived that achieves a desired tip orientation range while maximizing stability and respecting bending strain limits. This formulation also includes straight transmission segments at the proximal ends of the tubes. The result, confirmed by both numerical and physical experiment, enables designs with enhanced stability in comparison to designs of constant precurvature.

  8. Probabilistic integrity assessment of pressure tubes in an operating pressurized heavy water reactor

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Young-Jin; Park, Heung-Bae [KEPCO E and C, 188 Gumi-dong, Bundang-gu, Seongnam-si, Gyeonggi-do 463-870 (Korea, Republic of); Lee, Jung-Min; Kim, Young-Jin [School of Mechanical Engineering, Sungkyunkwan University, 300 Chunchun-dong, Jangan-gu, Suwon-si, Gyeonggi-do 440-746 (Korea, Republic of); Ko, Han-Ok [Korea Institute of Nuclear Safety, 34 Gwahak-ro, Yuseong-gu, Daejeon-si 305-338 (Korea, Republic of); Chang, Yoon-Suk, E-mail: yschang@khu.ac.kr [Department of Nuclear Engineering, Kyung Hee University, 1 Seocheon-dong, Giheung-gu, Yongin-si, Gyeonggi-do 446-701 (Korea, Republic of)

    2012-02-15

    Even though pressure tubes are major components of a pressurized heavy water reactor (PHWR), only small proportions of pressure tubes are sampled for inspection due to limited inspection time and costs. Since the inspection scope and integrity evaluation have been treated by using a deterministic approach in general, a set of conservative data was used instead of all known information related to in-service degradation mechanisms because of inherent uncertainties in the examination. Recently, in order that pressure tube degradations identified in a sample of inspected pressure tubes are taken into account to address the balance of the uninspected ones in the reactor core, a probabilistic approach has been introduced. In the present paper, probabilistic integrity assessments of PHWR pressure tubes were carried out based on accumulated operating experiences and enhanced technology. Parametric analyses on key variables were conducted, which were periodically measured by in-service inspection program, such as deuterium uptake rate, dimensional change rate of pressure tube and flaw size distribution. Subsequently, a methodology to decide optimum statistical distribution by using a robust method adopting a genetic algorithm was proposed and applied to the most influential variable to verify the reliability of the proposed method. Finally, pros and cons of the alternative distributions comparing with corresponding ones derived from the traditional method as well as technical findings from the statistical assessment were discussed to show applicability to the probabilistic assessment of pressure tubes.

  9. Effect of boric acid on intergranular corrosion in tube support plate crevices

    International Nuclear Information System (INIS)

    Brunet, J.P.; Campan, J.L.

    1993-10-01

    Intergranular attack on steam generator tubing is one important phenomenon involved in availability of Pressurized Water Reactors. Boric acid appears to be a possible candidate for inhibiting the corrosion process. The program performed in Cadarache was supposed to give statistical informations on the boric acid effect. It was based on a large number of samples initially attacked during a program performed by BABCOCK ampersand WILCOX. These samples were sleeved onto Alloy 690 tubes, in order to prevent premature cracking. Unfortunately it was not possible to find chemical conditions able to produce significant additional corrosion; we postulated mainly due to a drastic reduction of the thermal flux resulting from the increase of the tube wall thickness under the tube support plates (TSP). The tests demonstrate that such sleeve could be a possible remedy of the corrosion when introduced under the TSP. The tests show indications of a possible beneficial effect of the boric acid, a large variability of the heats sensitivity to the IGA and a predominant effect of Na 2 CO 3 on IGA production

  10. Power Holders and Social Dynamics of Participatory Development and Reconstruction: Cases from the Democratic Republic of Congo

    NARCIS (Netherlands)

    Kyamusugulwa, P.M.; Hilhorst, D.

    2015-01-01

    One of the challenges of participatory development and reconstruction programs is how and where to engage with power holders. This paper analyses the dynamics of power relations within a community-driven reconstruction program in the Democratic Republic of Congo. It shows that, in some

  11. A Method to Establishing Tube Plugging Criterion for Heat Exchangers with Straight Tubes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyungnam [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    The difference of thermal expansion coefficients between the shell and tube materials causes the stress in axial direction of tube. Because of the axial stress due to thermal load, the straight tubes are used for heat exchangers operated in low temperature such as CCW (Component Cooling Water) heat exchangers and condensers. It is inevitable for the materials of the components to be degraded as the power plants become older. The degradation accompanies increasing maintenance cost as well as creating safety issues. The materials and wall thickness of heat exchanger tubes in nuclear power plants are selected to withstand system temperature, pressure, and corrosion. There are many codes and standards to be referred for calculating the minimum thickness of the heat exchanger tube in the designing stage. However, the codes and standards related to show the tube plugging criteria may not exist currently. In this paper, a method to establish the tube plugging criteria of BOP heat exchangers, which is based on the USNRC Regulatory Guide 1.121, is introduced and the tube plugging criteria for the TPCCW heat exchanger of Yonggwang NPP No. 1 and 2. A method to establish the tube plugging criteria of heat exchangers with straight tubes are introduced based on the USNRC Regulatory Guide 1.121. As an example, the tube plugging criterion for the CCW heat exchanger of a nuclear power plant is provided.

  12. Inner surface modification of a tube by magnetic glow-arc plasma source ion implantation

    International Nuclear Information System (INIS)

    Zhang Guling; Chinese Academy of Sciences, Beijing; Wang Jiuli; Feng Wenran; Chen Guangliang; Gu Weichao; Niu Erwu; Fan Songhua; Liu Chizi; Yang Size; Wu Xingfang

    2006-01-01

    A new method named the magnetic glow-arc plasma source ion implantation (MGA-PSII) is proposed for inner surface modification of tubes. In MGA-PSII, under the control of an axial magnetic field, which is generated by an electric coil around the tube sample, glow arc plasma moves spirally into the tube from its two ends. A negative voltage applied on the tube realized its inner surface implantation. Titanium nitride (TiN) films are prepared on the inner surface of a stainless steel tube in diameter 90 mm and length 600 mm. Hardness tests show that the hardness at the tube centre is up to 20 GPa. XRD, XPS and AES analyses demonstrate that good quality of TiN films can be achieved. (authors)

  13. Inner Surface Modification of a Tube by Magnetic Glow-Arc Plasma Source Ion Implantation

    Science.gov (United States)

    Zhang, Gu-Ling; Wang, Jiu-Li; Wu, Xing-Fang; Feng, Wen-Ran; Chen, Guang-Liang; Gu, Wei-Chao; Niu, Er-Wu; Fan, Song-Hua; Liu, Chi-Zi; Yang, Si-Ze

    2006-05-01

    A new method named the magnetic glow-arc plasma source ion implantation (MGA-PSII) is proposed for inner surface modification of tubes. In MGA-PSII, under the control of an axial magnetic field, which is generated by an electric coil around the tube sample, glow arc plasma moves spirally into the tube from its two ends. A negative voltage applied on the tube realized its inner surface implantation. Titanium nitride (TiN) films are prepared on the inner surface of a stainless steel tube in diameter 90 mm and length 600 mm. Hardness tests show that the hardness at the tube centre is up to 20 GPa. XRD, XPS and AES analyses demonstrate that good quality of TiN films can be achieved.

  14. Development of automated lance systems for removing deposited sludge around heat transfer tubes with a trianglar pattern in a steam

    International Nuclear Information System (INIS)

    Hwang, K. S.; Sung, H. J.; Jeong, W. T.; Hong, S. Y.; Park, Y. S.

    2003-01-01

    Automated lance systems have been developed to remove sludge deposits filed up around the heat transfer tubes of a triangular pattern in a steam generator. The accessible ways of the lance systems inside the steam generator are the annulus region which occupies the space between the outermost tubes and the inner wall of the steam generator, and the Blowdown Lane region (BdL) without tubes along the centerline of the steam generator. The lance system along the annulus employes a slidable guide support rail and a lance body. The guide support rail, which is composed of two parallel circular rods with a vertical distance, is tightly fixed inside the hand holes. The guide support rail extends from a hand hole at 0 degree to the other hand hole at 180 degree. The lance body is slideably held on the guide support rail by means of supporting holders which are attached on both the bottom and the upper plates of the lance body. The lance body is comprised of a nozzle block with a nozzle cylinder and a first drive means which makes sweeping motion of the nozzle cylinder, a second drive means which aligns the direction of nozzle jets from the nozzle cylinder toward the desired tube lanes by rotating the nozzle block in the horizontal plane, and two side wall supporting wheel assemblies attached to the outer surface of the lance body, rolling along the inner wall of the steam generator. For the transportation of the lance, two control cables which extend outward through the hand holes are attached to both ends of the lance body and are driven by a drive means with a powered drum. The lance system along the blowdown lane adopts a horizontal guide support rail and a lance body which can convey three nozzle blocks for emitting high pressure water in the 30, 90 and 150 degree directions. By utilizing the above two lance systems, the shadow zones around the tubes where the high pressure water does not reach are highly reduced

  15. Effects of Two Purification Pretreatments on Electroless Copper Coating over Single-Walled Carbon Nano tubes

    International Nuclear Information System (INIS)

    Zheng, Z.; Li, L.; Dong, Sh.; Li, Sh.; Xiao, A.; Sun, Sh.

    2014-01-01

    To achieve the reinforcement of copper matrix composite by single-walled carbon nano tubes, a three-step-refluxing purification of carbon nano tubes sample with HNO 3 -NaOH-HCl was proposed and demonstrated. A previously reported purification process using an electromagnetic stirring with H 2 O 2 /HCl mixture was also repeated. Then, the purified carbon nano tubes were coated with copper by the same electroless plating process. At the end, the effects of the method on carbon nano tubes themselves and on copper coating were determined by transmission electron microscope spectroscopy, scanning electron microscope spectroscopy, X-ray diffractometry, thermogravimetric analysis, Fourier transformed infrared spectroscopy, and energy dispersive spectrometry. It was clearly confirmed that both of the two processes could remove most of iron catalyst particles and carbonaceous impurities without significant damage to carbon nano tubes. The thermal stability of the sample purified by H 2 O 2 /HCl treatment was slightly higher than that purified by HNO 3 -NaOH-HCl treatment. Nevertheless, the purification by HNO 3 -NaOH-HCl treatment was more effective for carboxyl functionalization on nano tubes than that by H 2 O 2 /HCl treatment. The Cu-coating on carbon nano tubes purified by both purification processes was complete, homogenous, and continuous. However, the Cu-coating on carbon nano tubes purified by H 2 O 2 /HCl was oxidized more seriously than those on carbon nano tubes purified by HNO 3 -NaOH-HCl treatment.

  16. A comparison of the test tube and the dialysis tubing in vitro methods for estimating the bioavailability of phosphorus in feed ingredients for swine.

    Science.gov (United States)

    Bollinger, David W; Tsunoda, Atsushi; Ledoux, David R; Ellersieck, Mark R; Veum, Trygve L

    2005-05-04

    The validity of a simplified in vitro test tube (TT) method was compared with a more complicated dialysis tubing (DT) method to estimate the percentage of available phosphorus (P) in 41 plant origin and five animal origin feed ingredients for swine. The TT method using 1.0 or 0.25 g samples was compared with the DT method using 1.0 g samples at two pancreatic incubation times (2 vs 4 h) in a 3 x 2 factorial arrangement of treatments. Each DT and TT method treatment was replicated three and six times, respectively. Both methods utilize three enzymatic digestions: (i) predigestion with endoxylanase and beta-glucanase for 1 h, (ii) pepsin digestion for 2 h, and (iii) pancreatin digestion for 2 or 4 h. For the TT method, the entire procedure was conducted in a 50 mL conical centrifuge tube and replicated six times. For the DT method, the first two digestions were conducted in a 10 mL plastic syringe before the contents were quantitatively transferred into a segment of DT for the pancreatic digestion. The percentages of hydrolyzed P for plant origin ingredients measured by the DT method using 1.0 g samples and the TT method using 0.25 g samples were highly correlated (r = 0.94-0.97, P or = 0.4) with published in vivo available P values. In conclusion, the accuracy and validity of the TT method using 0.25 g samples with a 2 h pancreatic digestion time was equal to or superior to the DT method using 1.0 g samples with a 4 h pancreatic digestion time for estimating P availability in plant origin feed ingredients.

  17. Fatigue behavior of highly porous titanium produced by powder metallurgy with temporary space holders

    Energy Technology Data Exchange (ETDEWEB)

    Özbilen, Sedat [Forschungszentrum Jülich, Institute of Energy and Climate Research (IEK), 52425 Jülich (Germany); Gazi University, Faculty of Technology, Department of Metallurgical and Materials Engineering, Teknikokullar, Ankara (Turkey); Liebert, Daniela [Forschungszentrum Jülich, Institute of Energy and Climate Research (IEK), 52425 Jülich (Germany); Beck, Tilmann [Forschungszentrum Jülich, Institute of Energy and Climate Research (IEK), 52425 Jülich (Germany); University of Kaiserslautern, Lehrstuhl für Werkstoffkunde (WKK), D-67663 Kaiserslautern (Germany); Bram, Martin, E-mail: m.bram@fz-juelich.de [Forschungszentrum Jülich, Institute of Energy and Climate Research (IEK), 52425 Jülich (Germany)

    2016-03-01

    Porous titanium cylinders were produced with a constant amount of temporary space holder (70 vol.%). Different interstitial contents were achieved by varying the starting powders (HDH vs. gas atomized) and manufacturing method (cold compaction without organic binders vs. warm compaction of MIM feedstocks). Interstitial contents (O, C, and N) as a function of manufacturing were measured by chemical analysis. Samples contained 0.34–0.58 wt.% oxygen, which was found to have the greatest effect on mechanical properties. Quasi-static mechanical tests under compression at low strain rate were used for reference and to define parameters for cyclic compression tests. Not unexpectedly, increased oxygen content increased the yield strength of the porous titanium. Cyclic compression fatigue tests were conducted using sinusoidal loading in a servo-hydraulic testing machine. Increased oxygen content was concomitant with embrittlement of the titanium matrix, resulting in significant reduction of compression cycles before failure. For samples with 0.34 wt.% oxygen, R, σ{sub min} and σ{sub max} were varied systematically to estimate the fatigue limit (~ 4 million cycles). Microstructural changes induced by cyclic loading were then characterized by optical microscopy, SEM and EBSD. - Highlights: • Systematic variation of the oxygen content from 0.34 to 0.58 wt.%. • Systematic study of the relationship between fatigue limit and oxygen content. • Critical oxygen equivalent seems to be 0.35 wt.% to avoid embrittlement. • Identification of the failure modes by light microscopy, SEM and EBSD.

  18. Rapid surface sampling and archival record system (RSSAR)

    International Nuclear Information System (INIS)

    Barren, E.; Bracco, A.; Dorn, S.B.

    1997-01-01

    Purpose is to develop a rapid surface (concrete, steel) contamination measurement system that will provide a ''quick-look'' indication of contamination areas, an archival record, and an automated analysis. A bulk sampling oven is also being developed. The sampling device consists of a sampling head, a quick look detector, and an archiving system (sorbent tube). The head thermally desorbs semi-volatiles, such as PCBs, oils, etc., from concrete and steel surfaces; the volatilized materials are passed through a quick-look detector. Sensitivity of the detector can be attenuated for various contaminant levels. Volatilized materials are trapped in a tube filled with adsorbent. The tubes are housed in a magazine which also archives information about sampling conditions. Analysis of the tubes can be done at a later date. The concrete sampling head is fitted with a tungsten-halogen lamp; in laboratory experiments it has extracted model contaminants by heating the top 4mm of the surface to 250 C within 100-200 s. The steel sampling head has been tested on different types of steels and has extracted model contaminants within 30 s. A mathematical model of heat and mass transport in concrete has been developed. Rate of contaminant removal is at maximum when the moisture content is about 100 kg/m 3 . The system will be useful during decontamination and decommissioning operations

  19. Automation in tube finishing bay

    International Nuclear Information System (INIS)

    Bhatnagar, Prateek; Satyadev, B.; Raghuraman, S.; Syama Sundara Rao, B.

    1997-01-01

    Automation concept in tube finishing bay, introduced after the final pass annealing of PHWR tubes resulted in integration of number of sub-systems in synchronisation with each other to produce final cut fuel tubes of specified length, tube finish etc. The tube finishing bay which was physically segregated into four distinct areas: 1. tube spreader and stacking area, 2. I.D. sand blasting area, 3. end conditioning, wad blowing, end capping and O.D. wet grinding area, 4. tube inspection, tube cutting and stacking area has been studied

  20. Storing of Extracts in Polypropylene Microcentrifuge Tubes Yields Contaminant Peak During Ultra-flow Liquid Chromatographic Analysis.

    Science.gov (United States)

    Kshirsagar, Parthraj R; Hegde, Harsha; Pai, Sandeep R

    2016-05-01

    This study was designed to understand the effect of storage in polypropylene microcentrifuge tubes and glass vials during ultra-flow liquid chromatographic (UFLC) analysis. One ml of methanol was placed in polypropylene microcentrifuge tubes (PP material, Autoclavable) and glass vials (Borosilicate) separately for 1, 2, 4, 8, 10, 20, 40, and 80 days intervals stored at -4°C. Contaminant peak was detected in methanol stored in polypropylene microcentrifuge tubes using UFLC analysis. The contaminant peak detected was prominent, sharp detectable at 9.176 ± 0.138 min on a Waters 250-4.6 mm, 4 μ, Nova-Pak C18 column with mobile phase consisting of methanol:water (70:30). It was evident from the study that long-term storage of biological samples prepared using methanol in polypropylene microcentrifuge tubes produce contaminant peak. Further, this may mislead in future reporting an unnatural compound by researchers. Long-term storage of biological samples prepared using methanol in polypropylene microcentrifuge tubes produce contaminant peakContamination peak with higher area under the curve (609993) was obtained in ultra-flow liquid chromatographic run for methanol stored in PP microcentrifuge tubesContamination peak was detected at retention time 9.113 min with a lambda max of 220.38 nm and 300 mAU intensity on the given chromatographic conditionsGlass vials serve better option over PP microcentrifuge tubes for storing biological samples. Abbreviations used: UFLC: Ultra Flow Liquid Chromatography; LC: Liquid Chromatography; MS: Mass spectrometry; AUC: Area Under Curve.

  1. CRL X-ray tube

    International Nuclear Information System (INIS)

    Kolchevsky, N.N.; Petrov, P.V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed. (authors)

  2. Advanced UXO Discrimination using Magnetometry: Understanding Remanent Magnetization

    Science.gov (United States)

    2009-09-01

    moments of steel samples. The MRIP comprises six three-component fluxgate magnetometers symmetrically distributed around a rotating sample holder. Samples...comprises six three- component fluxgate magnetometers symmetrically distributed around a rotating sample holder. Samples are placed on the holder... fluxgate magnetometers symmetrically distributed around a rotating sample holder. Samples are placed on the holder and are slowly spun through two

  3. 40 CFR 141.21 - Coliform sampling.

    Science.gov (United States)

    2010-07-01

    ... the sample produces a turbid culture in the absence of gas production using an analytical method where gas formation is examined (e.g., the Multiple-Tube Fermentation Technique), produces a turbid culture... °C for 24 ±2 hours. Gas production of any amount in the inner fermentation tube of the EC medium...

  4. Pediatric cuffed endotracheal tubes

    Directory of Open Access Journals (Sweden)

    Neerja Bhardwaj

    2013-01-01

    Full Text Available Endotracheal intubation in children is usually performed utilizing uncuffed endotracheal tubes for conduct of anesthesia as well as for prolonged ventilation in critical care units. However, uncuffed tubes may require multiple changes to avoid excessive air leak, with subsequent environmental pollution making the technique uneconomical. In addition, monitoring of ventilatory parameters, exhaled volumes, and end-expiratory gases may be unreliable. All these problems can be avoided by use of cuffed endotracheal tubes. Besides, cuffed endotracheal tubes may be of advantage in special situations like laparoscopic surgery and in surgical conditions at risk of aspiration. Magnetic resonance imaging (MRI scans in children have found the narrowest portion of larynx at rima glottides. Cuffed endotracheal tubes, therefore, will form a complete seal with low cuff pressure of <15 cm H 2 O without any increase in airway complications. Till recently, the use of cuffed endotracheal tubes was limited by variations in the tube design marketed by different manufacturers. The introduction of a new cuffed endotracheal tube in the market with improved tracheal sealing characteristics may encourage increased safe use of these tubes in clinical practice. A literature search using search words "cuffed endotracheal tube" and "children" from 1980 to January 2012 in PUBMED was conducted. Based on the search, the advantages and potential benefits of cuffed ETT are reviewed in this article.

  5. Volatile Constituents, Inorganic Elements and Primary Screening of Bioactivity of Black Coral Cigarette Holders

    Directory of Open Access Journals (Sweden)

    Ganggang Shi

    2011-05-01

    Full Text Available Black corals (BC have been used for a long time in Chinese medicine, and may have some pharmaceutical functions when used as material for cigarette holders in southeast China. This study is aimed to investigate the bioactivities of volatile constituents in BC and to explore the folklore behind the use of BC cigarette holders (BCCHs. We extracted the volatile constituents of BC by supercritical fluid extraction (SFE with carbon dioxide (CO2-SFE, then identified and analyzed the constituents by gas chromatography-mass spectrometry (GC-MS. In total, 15 components were reliably identified in BC and found to be biologically active. These included triethyl phosphate, butylated hydroxytoluene, cedrol, n-hexadecanoic acid, squalene, and cholesterol. Meanwhile 13 inorganic elements (P, Ca, Mg, S, B, Si, Fe, Cu, Zn, Ba, etc. were determined by inductively coupled plasma spectrometer (ICPS. In the bioactivity tests, the BC extract (BCE showed a scavenging activity of 2,2-diphenyl-1-picrylhydrazyl free radicals and hydroxyl radicals by phenanthroline-Fe (II oxidation and moderate inhibition of Gram-positive microorganisms. The antioxidant and antimicrobial activities of BC, which are related to the active chemical composition, may explain the perceived benefit for cigarette smokers who use BCCHs.

  6. Electrophoretic deposition of graphene oxide onto carbon fibers for in-tube solid-phase microextraction.

    Science.gov (United States)

    Feng, Juanjuan; Wang, Xiuqin; Tian, Yu; Bu, Yanan; Luo, Chuannan; Sun, Min

    2017-09-29

    Carbon fibers (CFs) were functionalized with graphene oxide (GO) by an electrophoretic deposition (EPD) method for in-tube solid-phase microextraction (SPME). GO-CFs were filled into a poly(ether ether ketone) (PEEK) tube to obtain a fibers-in-tube SPME device, which was connected with high performance liquid chromatography (HPLC) equipment to build online SPME-HPLC system. Compared with CFs, GO-CFs presented obviously better extraction performance, due to excellent adsorption property and large surface area of GO. Using ten polycyclic aromatic hydrocarbons (PAHs) as model analytes, the important extraction conditions were optimized, such as sample flow rate, extraction time, organic solvent content and desorption time. An online analysis method was established with wide linear range (0.01-50μgL -1 ) and low detection limits (0.001-0.004μgL -1 ). Good sensitivity resulted from high enrichment factors (1133-3840) of GO-CFs in-tube device towards PAHs. The analysis method was used to online determination of PAHs in wastewater samples. Some target analytes were detected and relative recoveries were in the range of 90.2-112%. It is obvious that the proposed GO-CFs in-tube device was an efficient extraction device, and EPD could be used to develop nanomaterials functionalized sorbents for sample preparation. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Simple tube centrifugation for processing platelet-rich plasma in the horse.

    Science.gov (United States)

    Fontenot, Robin L; Sink, Carolyn A; Werre, Stephen R; Weinstein, Nicole M; Dahlgren, Linda A

    2012-12-01

    This study evaluated the quality and bacteriologic safety of platelet-rich plasma (PRP) produced by 3 simple, inexpensive tube centrifugation methods and a commercial system. Citrated equine blood collected from 26 normal horses was processed by 4 methods: blood collection tubes centrifuged at 1200 and 2000 × g, 50-mL conical tube, and a commercial system. White blood cell (WBC), red blood cell (RBC), and platelet counts and mean platelet volume (MPV) were determined for whole blood and PRP, and aerobic and anaerobic cultures were performed. Mean platelet concentrations ranged from 1.55- to 2.58-fold. The conical method yielded the most samples with platelet concentrations greater than 2.5-fold and within the clinically acceptable range of > 250,000 platelets/μL. White blood cell counts were lowest with the commercial system and unacceptably high with the blood collection tubes. The conical tube method may offer an economically feasible and comparatively safe alternative to commercial PRP production systems.

  8. First characterization of the Hamamatsu R11265 multi-anode photomultiplier tube

    International Nuclear Information System (INIS)

    Calvi, M.; Cassina, L.; Giachero, A.; Gotti, C.; Maino, M.; Matteuzzi, C.; Pessina, G.

    2014-01-01

    The characterization of the new Hamamatsu R11265-103-M64 multi-anode photomultiplier tube is presented. The sample available in our laboratory was tested and in particular the response to single photon was extensively studied. The gain, the anode uniformity and the dark current were measured. The tube behaviour in a longitudinal magnetic field up to 100 G was studied and the gain loss due to the ageing was quantified. The characteristics and performance of the photomultiplier tube make the R11265-103-M64 particularly tailored for an application in high energy physics experiments, such as in the LHCb Ring Imaging Cherenkov (RICH) detector at LHC. - Highlights: • We tested the new Hamamatsu R11265-103-M64 multi-anode photomultiplier tube. • We studied the response to single photon, the gain and the anode uniformity. • The tube behaviour in a longitudinal magnetic field up to 100 G was studied. • The gain loss due to the aging was quantified

  9. Manufacturing process optimization of nuclear fuel guide tube using HANA alloys

    International Nuclear Information System (INIS)

    Jeong, Yong Hwan; Park, S. Y.; Choi, B. K.; Park, J. Y.; Kim, H. G.; Jeong, Y. I.; Park, D. J.; Lim, J. K.

    2010-08-01

    From this project, the advanced manufacturing parameters which were contained of heat-treatment, reduction rate, and new process (2 step) were considered to increase the guide tube performance of HANA material. It was obtained that the strength and corrosion resistance of HANA material were improved by applying the improve manufacturing parameters when compared to the commercial guide tube material. · Manufacturing parameter study to increase mechanical property -Tensile strength increase of 30% by manufacturing parameter setup when compared to the guide tube specification · Manufacturing parameter study to decrease irradiation growth -Theoretical study of the texture effect on sample specimens related to the irradiation growth · Manufacturing parameter study to increase corrosion resistance -Corrosion resistance increase of 30% by manufacturing parameter setup when compared to the commercial guide tube

  10. 48 CFR 339.7001 - Request for approval to make an award to other than a GSA BPA holder.

    Science.gov (United States)

    2010-10-01

    ... Use of General Services Administration Blanket Purchase Agreements for Independent Risk Analysis... micro-purchase threshold, that obtaining the required services from a source other than a GSA BPA holder... include additional supporting rationale to document the best value decision, as appropriate. ...

  11. The extent of unwanted infrared photoacoustic signals from polymer sampling tubings exposed to ultraviolet radiation

    NARCIS (Netherlands)

    Bicanic, D.; Solyom, A.; Angeli, G.; Wegh, H.; Postumus, M.; Jalink, H.

    1995-01-01

    The extent of unwanted photoacoustic (PA) signals due to volatiles released from various polymer tubing materials [transparent, red and black polyethylene (PE), polymer of tetrafluorethylene (PTFE) and copolymer of tetrafluorethylene and hexafluorethylene (FEP)] when exposed to 245 nm radiation was

  12. Assessment of need for transport tubes when continuously monitoring for radioactive aerosols

    Energy Technology Data Exchange (ETDEWEB)

    Whicker, J.J.; Rodgers, J.C.; Lopez, R.C.

    1999-09-01

    Aerosol transport tubes are often used to draw aerosol from desirable sampling locations to nearby air sampling equipment that cannot be placed at that location. In many plutonium laboratories at Los Alamos National Laboratory, aerosol transport tubes are used to transport aerosol from the front of room ventilation exhaust registers to continuous air monitors (CAMs) that are mounted on nearby walls. Despite designs to minimize particle loss in tubes, aerosol transport model predictions suggest losses occur lowering the sensitivity of CAMs to accidentally released plutonium aerosol. The goal of this study was to test the hypotheses that the reliability, speed, and sensitivity of aerosol detection would be equal whether the sample was extracted from the front of the exhaust register or from the wall location of CAMs. Polydisperse oil aerosols were released from multiple locations in two plutonium laboratories to simulate plutonium aerosol releases. Networked laser particle counters (LPCs) were positioned to simultaneously measure time-resolved aerosol concentrations at each exhaust register and at each wall-mounted CAM location.

  13. Pressure tube type research reactor

    International Nuclear Information System (INIS)

    Ueda, Hiroshi.

    1976-01-01

    Object: To prevent excessive heat generation due to radiation of a pressure tube vessel. Structure: A pressure tube encasing therein a core comprises a dual construction comprising inner and outer tubes coaxially disposed. High speed cooling water is passed through the inner tube for cooling. In addition, in the outer periphery of said outer tube there is provided a forced cooling tube disposed coaxially thereto, into which cooling fluid, for example, such as moderator or reflector is forcibly passed. This forced cooling tube has its outer periphery surrounded by the vessel into which moderator or reflector is fed. By the provision of the dual construction of the pressure tube and the forced cooling tube, the vessel may be prevented from heat generation. (Ikeda, J.)

  14. Streak tube development

    International Nuclear Information System (INIS)

    Hinrichs, C.K.; Estrella, R.M.

    1979-01-01

    A research program for the development of a high-speed, high-resolution streak image tube is described. This is one task in the development of a streak camera system with digital electronic readout, whose primary application is for diagnostics in underground nuclear testing. This program is concerned with the development of a high-resolution streak image tube compatible with x-ray input and electronic digital output. The tube must be capable of time resolution down to 100 psec and spatial resolution to provide greater than 1000 resolution elements across the cathode (much greater than presently available). Another objective is to develop the capability to make design changes in tube configurations to meet different experimental requirements. A demountable prototype streak tube was constructed, mounted on an optical bench, and placed in a vacuum system. Initial measurements of the tube resolution with an undeflected image show a resolution of 32 line pairs per millimeter over a cathode diameter of one inch, which is consistent with the predictions of the computer simulations. With the initial set of unoptmized deflection plates, the resolution pattern appeared to remain unchanged for static deflections of +- 1/2-inch, a total streak length of one inch, also consistent with the computer simulations. A passively mode-locked frequency-doubled dye laser is being developed as an ultraviolet pulsed light source to measure dynamic tube resolution during streaking. A sweep circuit to provide the deflection voltage in the prototype tube has been designed and constructed and provides a relatively linear ramp voltage with ramp durations adjustable between 10 and 1000 nsec

  15. Análise de fármacos em material biológico: acoplamento microextração em fase sólida "no tubo" e cromatografia líquida de alta eficiência Analysis of drugs in biological samples: automated "in-tube" solid-phase microextraction and high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Maria Eugênia C. Queiroz

    2005-10-01

    Full Text Available A new solid phase microextraction (SPME system, known as in-tube SPME, was recently developed using an open tubular fused-silica capilary column, instead of an SPME fiber, as the SPME device. On-line in-tube SPME is usually used in combination with high performance liquid chromatography. Drugs in biological samples are directly extracted and concentrated in the stationary phase of capillary columns by repeated draw/eject cycles of sample solution, and then directly transferred to the liquid chromatographic column. In-tube SPME is suitable for automation. Automated sample handling procedures not only shorten the total analysis time, but also usually provide better accuracy and precision relative to manual techniques. In-tube SPME has been demonstrated to be a very effective and highly sensitive technique to determine drugs in biological samples for various purposes such as therapeutic drug monitoring, clinical toxicology, bioavailability and pharmacokinetics.

  16. Preparation of tubular urease immobilized on the inner wall of glass tube by radiation-polymerization

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Y; Hayashi, T; Kawashima, K [National Food Research Inst., Yatabe, Ibaraki (Japan); Oka, O

    1981-03-01

    A method to prepare immobilized urease on the inner wall of a glass tube by radiation-polymerization under frozen state was investigated. As a part of a continuous flow analyzer, i.w.. Technicon Auto Analyzer II, the immobilized urease tube of 1 cm length was set and used for the routine determination of urea. This flow-through system could measure urea concentration of up to 30 mM at rate of 30 samples per hour. The system were possible to assay 2000 to 3000 samples, continuously in practice. The activity of the urease tube stored in a refrigerator maintained 94% of the initial activity after 115 days.

  17. Preparation of tubular urease immobilized on the inner wall of glass tube by radiation-polymerization

    International Nuclear Information System (INIS)

    Tanaka, Yoshikazu; Hayashi, Toru; Kawashima, Koji; Oka, Osamu.

    1981-01-01

    A method to prepare immobilized urease on the inner wall of a glass tube by radiation-polymerization under frozen state was investigated. As a part of a continuous flow analyzer, i.w.. Technicon Auto Analyzer II, the immobilized urease tube of 1 cm length was set and used for the routine determination of urea. This flow-through system could measure urea concentration of up to 30 mM at rate of 30 samples per hour. The system were possible to assay 2000 to 3000 samples, continuously in practice. The activity of the urease tube stored in a refrigirator maintained 94% of the initial activity after 115 days. (author)

  18. Extracorporeal tubing in the roller pump raceway: physical changes and particulate generation.

    Science.gov (United States)

    Spiwak, Allison J Bednarski; Horbal, Alexander; Leatherbury, Robert; Hansford, Derek J

    2008-09-01

    Plasticized polyvinyl chloride tubing is used as the blood conduit in the heart lung bypass circuit. The section in the roller pump undergoes rigorous compression. Fatigue leads to material changes in weight and length of the bulk material. Particles are released during normal pump operation. This study evaluates the time course of particle loss. Three segments of 1/2" ID tubing run in the raceway for 30-minute, 1-hour, or 2-hour. The fluid path of each segment includes an oxygenator; a castor oil blend was used for the prime. The 5 mL sample was acquired at 10 minute intervals. Raceway tubing segments were measured for a change in weight and length. The same procedure repeated with 1/4" ID and 3/8" ID tubing. All tubing increased at least 5 mm by the 2-hour trial. There were no remarkable changes in weight. Particles were measured for size and percent volume. Tubing with 1/2" ID performed most consistently for particle release during all trials. Particles were observed as small as 1 nm. Particles as large as 3 micron could be confirmed. For all tubing there was particle release by 30 minutes. Perfusionists must consider tubing inner diameter and wall thickness in choosing the pPVC for the raceway in order to minimize particulate emboli. This research suggests that 3/8" ID tubing produces spalls inconsistently compared to 2" ID tubing. Thinner wall thickness tubing also has the potential to limit spall formation.

  19. Contamination risk of stable isotope samples during milling.

    Science.gov (United States)

    Isaac-Renton, M; Schneider, L; Treydte, K

    2016-07-15

    Isotope analysis of wood is an important tool in dendrochronology and ecophysiology. Prior to mass spectrometry analysis, wood must be homogenized, and a convenient method involves a ball mill capable of milling samples directly in sample tubes. However, sample-tube plastic can contaminate wood during milling, which could lead to biological misinterpretations. We tested possible contamination of whole wood and cellulose samples during ball-mill homogenization for carbon and oxygen isotope measurements. We used a multi-factorial design with two/three steel milling balls, two sample amounts (10 mg, 40 mg), and two milling times (5 min, 10 min). We further analyzed abrasion by milling empty tubes, and measured the isotope ratios of pure contaminants. A strong risk exists for carbon isotope bias through plastic contamination: the δ(13) C value of polypropylene deviated from the control by -6.77‰. Small fibers from PTFE filter bags used during cellulose extraction also present a risk as the δ(13) C value of this plastic deviated by -5.02‰. Low sample amounts (10 mg) showed highest contamination due to increased abrasion during milling (-1.34‰), which is further concentrated by cellulose extraction (-3.38‰). Oxygen isotope measurements were unaffected. A ball mill can be used to homogenize samples within test tubes prior to oxygen isotope analysis, but not prior to carbon or radiocarbon isotope analysis. There is still a need for a fast, simple and contamination-free sample preparation procedure. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  20. Reliability of eddy current examination of steam generator tubes

    International Nuclear Information System (INIS)

    Birks, A.S.; Ferris, R.H.; Doctor, P.G.; Clark, R.A.; Spanner, G.E.

    1985-04-01

    A unique study of nondestructive examination reliability is underway at the Pacific Northwest Laboratory under US Nuclear Regulatory Commission sponsorship. Project participants include the Electric Power Research Institute and consortiums from France, Italy, and Japan. This study group has conducted a series of NDE examinations of tubes from a retired-from-service steam generator, using commercially available multifrequency eddy current equipment and ASME procedures. The examination results have been analyzed to identify factors contributing to variations in NDE inspection findings. The reliability of these examinations will then be validated by destructive analyses of the steam generator tubes. The program is expected to contribute to development of a model for steam generator inservice inspection sampling plans and inspection periods, as well as to improved regulatory guidelines for tube plugging

  1. Study of the sealing performance of tubing adapters in gas-tight deep-sea water sampler

    Directory of Open Access Journals (Sweden)

    Huang Haocai

    2014-09-01

    Full Text Available Tubing adapter is a key connection device in Gas-Tight Deep-Sea Water Sampler (GTWS. The sealing performance of the tubing adapter directly affects the GTWS’s overall gas tightness. Tubing adapters with good sealing performance can ensure the transmission of seawater samples without gas leakage and can be repeatedly used. However, the sealing performance of tubing adapters made of different materials was not studied sufficiently. With the research discussed in this paper, the materials match schemes of the tubing adapters were proposed. With non-linear finite element contact analysis and sea trials in the South China Sea, it is expected that the recommended materials match schemes not only meet the requirements of tubing adapters' sealing performance but also provide the feasible options for the following research on tubing adapters in GTWS

  2. Study of the sealing performance of tubing adapters in gas-tight deep-sea water sampler

    Directory of Open Access Journals (Sweden)

    Haocai Huang

    2014-09-01

    Full Text Available Tubing adapter is a key connection device in Gas-Tight Deep-Sea Water Sampler (GTWS. The sealing performance of the tubing adapter directly affects the GTWS's overall gas tightness. Tubing adapters with good sealing performance can ensure the transmission of seawater samples without gas leakage and can be repeatedly used. However, the sealing performance of tubing adapters made of different materials was not studied sufficiently. With the research discussed in this paper, the materials match schemes of the tubing adapters were proposed. With non-linear finite element contact analysis and sea trials in the South China Sea, it is expected that the recommended materials match schemes not only meet the requirements of tubing adapters’ sealing performance but also provide the feasible options for the following research on tubing adapters in GTWS.

  3. Technique employed to seal a tube leaking in a heat exchanger of the tube type by explosives with supporting means for the adjacent tubes

    International Nuclear Information System (INIS)

    Larson, G.C.

    1978-01-01

    This invention concerns the technique employed to seal a tube leaking in a heat exchanger of the tube and tube plate type by detonating metal plugs activated by an explosive and inserted in both ends of the tube. It refers in particular to an apparatus and process in which the deformation or distortion of the adjacent tubes and tube plate ties under the effect of the explosive forces is significantly reduced [fr

  4. A flow-through amperometric sensor based on dialysis tubing and free enzyme reactors

    NARCIS (Netherlands)

    Bohm, S.; Pijanowska, D.G.; Pijanowska, D.; Olthuis, Wouter; Bergveld, Piet

    2001-01-01

    A generic flow-through amperometric microenzyme sensor is described, which is based on semi-permeable dialysis tubing carrying the sample to be analyzed. This tubing (300 μm OD) is led through a small cavity, containing the working and reference electrode. By filling this cavity with a few μl of an

  5. Portrayal of smokeless tobacco in YouTube videos.

    Science.gov (United States)

    Bromberg, Julie E; Augustson, Erik M; Backinger, Cathy L

    2012-04-01

    Videos of smokeless tobacco (ST) on YouTube are abundant and easily accessible, yet no studies have examined the content of ST videos. This study assesses the overall portrayal, genre, and messages of ST YouTube videos. In August 2010, researchers identified the top 20 search results on YouTube by "relevance" and "view count" for the following search terms: "ST," "chewing tobacco," "snus," and "Skoal." After eliminating videos that were not about ST (n = 26), non-English (n = 14), or duplicate (n = 42), a final sample of 78 unique videos was coded for overall portrayal, genre, and various content measures. Among the 78 unique videos, 15.4% were anti-ST, while 74.4% were pro-ST. Researchers were unable to determine the portrayal of ST in the remaining 10.3% of videos because they involved excessive or "sensationalized" use of the ST, which could be interpreted either positively or negatively, depending on the viewer. The most common ST genre was positive video diaries (or "vlogs"), which made up almost one third of the videos (29.5%), followed by promotional advertisements (20.5%) and anti-ST public service announcements (12.8%). While YouTube is intended for user-generated content, 23.1% of the videos were created by professional organizations. These results demonstrate that ST videos on YouTube are overwhelmingly pro-ST. More research is needed to determine who is viewing these ST YouTube videos and how they may affect people's knowledge, attitudes, and behaviors regarding ST use.

  6. Human blood RNA stabilization in samples collected and transported for a large biobank

    Science.gov (United States)

    2012-01-01

    Background The Norwegian Mother and Child Cohort Study (MoBa) is a nation-wide population-based pregnancy cohort initiated in 1999, comprising more than 108.000 pregnancies recruited between 1999 and 2008. In this study we evaluated the feasibility of integrating RNA analyses into existing MoBa protocols. We compared two different blood RNA collection tube systems – the PAXgene™ Blood RNA system and the Tempus™ Blood RNA system - and assessed the effects of suboptimal blood volumes in collection tubes and of transportation of blood samples by standard mail. Endpoints to characterize the samples were RNA quality and yield, and the RNA transcript stability of selected genes. Findings High-quality RNA could be extracted from blood samples stabilized with both PAXgene and Tempus tubes. The RNA yields obtained from the blood samples collected in Tempus tubes were consistently higher than from PAXgene tubes. Higher RNA yields were obtained from cord blood (3 – 4 times) compared to adult blood with both types of tubes. Transportation of samples by standard mail had moderate effects on RNA quality and RNA transcript stability; the overall RNA quality of the transported samples was high. Some unexplained changes in gene expression were noted, which seemed to correlate with suboptimal blood volumes collected in the tubes. Temperature variations during transportation may also be of some importance. Conclusions Our results strongly suggest that special collection tubes are necessary for RNA stabilization and they should be used for establishing new biobanks. We also show that the 50,000 samples collected in the MoBa biobank provide RNA of high quality and in sufficient amounts to allow gene expression analyses for studying the association of disease with altered patterns of gene expression. PMID:22988904

  7. Measured thermal and fast neutron fluence rates for ATF-1 holders during ATR cycle 158B/159A

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Larry Don [Idaho National Lab. (INL), Idaho Falls, ID (United States); Miller, David Torbet [Idaho National Lab. (INL), Idaho Falls, ID (United States); Walker, Billy Justin [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-11-01

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 158B/159A which were measured by the Radiation Measurements Laboratory (RML).

  8. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1983-08-01

    A review of the performance of steam generator tubes in 110 water-cooled nuclear power reactors showed that tubes were plugged at 46 (42 percent) of the reactors. The number of tubes removed from service increased from 1900 (0.14 percent) in 1980 to 4692 (0.30 percent) in 1981. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that used all-volatile treatment since start-up. At one reactor a large number of degraded tubes were repaired by sleeving which is expected to become an important method of tube repair in the future

  9. Development and performance of inspection equipment for pressure tubes in Fugen

    International Nuclear Information System (INIS)

    Naruo, Kazuteru; Tanimoto, Ken-ichi; Ohta, Takeo; Nakamura, Takahisa; Imaizumi, Kiyoshi.

    1984-01-01

    The pressure tubes of Fugen are the important equipment as the many tubes compose the core, and since they are made of Zr-2.5% Nb alloy which has been used for the first time in Japan, they have become the object of monitoring (the follow-up investigation of the change of inside diameter, the presence of defects and so on) in addition to the in-service inspection. In this paper, on the inspection equipment for pressure tubes, that has been developed independently by the Power Reactor and Nuclear Fuel Development Corp. in order to carry out the ISI and monitoring, the course of development and the construction and the performance are reported, and the results of having used it for the fourth regular inspection of Fugen are described. The 10-year plan of the ISI and monitoring of pressure tubes is shown. The core of Fugen is composed of 224 pressure tubes, therefore, the inspection is carried out by sampling inspection. The monitoring is carried out on four tubes for the follow-up investigation and one tube that shows the severest operation history at the time of inspection. The equipment performs ultrasonic flaw detection, the measurement of inside diameter and the visual inspection of internal surface. (Kako, I.)

  10. Study on antioxidant experiment on forged steel tube sheet and tube hole for steam generator

    International Nuclear Information System (INIS)

    Zong Hai; Wang Detai; Ding Yang

    2012-01-01

    Antioxidant experiment on forged steel tube sheet and tube hole for steam generator was studied and the influence of different simulated heat treatments on the antioxidant performance of tube sheet and tube hole was made. The influence of different antioxidant methods on the size of tube hole was drawn. Furthermore, the change of size and weight of 18MnD5 forged steel tube sheet on the condition of different simulated heat treatments was also studied. The analytical results have proved reference information for the use of 18MnD5 material and for key processes of processing tube hole and wearing and expanding U-style tube. (authors)

  11. SEAMIST trademark soil sampling for tritiated water: First year's results

    International Nuclear Information System (INIS)

    Mallon, B.; Martins, S.A.; Houpis, J.L.; Lowry, W.; Cremer, C.D.

    1992-01-01

    SEAMIST trademark is a recently developed sampling system that enables one to measure various soil parameters by means of an inverted, removable, impermeable membrane tube inserted in a borehole. This membrane tube can have various measuring devices installed on it, such as gas ports, adsorbent pads, and electrical sensors. These membrane tubes are made of a laminated polymer. The Lawrence Livermore National Laboratory in Livermore, California, has installed two of these systems to monitor tritium in soil resulting from a leak in an underground storage tank. One tube is equipped with gas ports to sample soil vapor and the other with adsorbent pads to sample soil moisture. Borehole stability was maintained using either sand-filled or air-inflated tubes. Both system implementations yielded concentrations or activities that compared well with the measured concentrations of tritium in the soil taken during borehole construction. In addition, an analysis of the data suggest that both systems prevented the vertical migration of tritium in the boreholes. Also, a neutron probe was successfully used in a blank membrane inserted in one of the boreholes to monitor the moisture in the soil without exposing the probe to the tritium. The neutron log showed excellent agreement with the soil moisture content measured in soil samples taken during borehole construction. This paper describes the two SEAMIST trademark systems used and presents sampling results and comparisons

  12. Characterization of Friction Stir Welded Tubes by Means of Tube Bulge Test

    International Nuclear Information System (INIS)

    D'Urso, G.; Longo, M.; Giardini, C.

    2011-01-01

    Mechanical properties of friction stir welded joints are generally evaluated by means of conventional tensile test. This testing method might provide insufficient information because maximum strain obtained in tensile test before necking is small; moreover, the application of tensile test is limited when the joint path is not linear or even when the welds are executed on curved surfaces. Therefore, in some cases, it would be preferable to obtain the joints properties from other testing methods. Tube bulge test can be a valid solution for testing circumferential or longitudinal welds executed on tubular workpieces. The present work investigates the mechanical properties and the formability of friction stir welded tubes by means of tube bulge tests. The experimental campaign was performed on tubular specimens having a thickness of 3 mm and an external diameter of 40 mm, obtained starting from two semi-tubes longitudinally friction stir welded. The first step, regarding the fabrication of tubes, was performed combining a conventional forming process and friction stir welding. Sheets in Al-Mg-Si-Cu alloy AA6060 T6 were adopted for this purpose. Plates having a dimension of 225x60 mm were bent (with a bending axis parallel to the main dimension) in order to obtain semi-tubes. A particular care was devoted to the fabrication of forming devices (punch and die) in order to minimize the springback effects. Semi-tubes were then friction stir welded by means of a CNC machine tool. Some preliminary tests were carried out by varying the welding parameters, namely feed rate and rotational speed. A very simple tool having flat shoulder and cylindrical pin was used. The second step of the research was based on testing the welded tubes by means of tube bulge test. A specific equipment having axial actuators with a conical shape was adopted for this study. Some analyses were carried out on the tubes bulged up to a certain pressure level. In particular, the burst pressure and the

  13. Heat exchanger with layers of helical tubes provided with improved tube supports

    International Nuclear Information System (INIS)

    Carnoy, M.; Mathieu, B.; Renaux, C.

    1986-01-01

    The present heat exchanger comprises coaxial layers of helically wound tubes; these tubes are supported by support plates, each comprising a row of perforations through which the tubes of a same layer pass. Truncated sleeves are in compression around the tubes within the perforations and mounted on the support plates. Pins fix the plates of different layers together against transverse movement but allowing radial movement. The present invention finds an application with nuclear reactor steam generators [fr

  14. Safeguards-relevant information collection from small holders – experiences and challenges

    International Nuclear Information System (INIS)

    Sundén, Erika; Dufva, Martina; Dahlberg, Joakim

    2015-01-01

    A number of universities, research institutions, hospitals, and other businesses are in possession of relatively small amounts of nuclear material. In some cases the material is in activities related to the nuclear fuel cycle, but there is also a wide variety of other applications. Regardless of application, material accountancy must be reported to the European Commission (EC) and, in Sweden, to the Swedish Radiation Safety Authority (SSM). However, checking the completeness and correctness of the reports from operators with very small amounts of nuclear material can easily be forgotten or viewed as being less important. Starting in the beginning of 2013 SSM increased its effort in this area and began working more actively gathering information and checking its correctness. Informing the operators in possession of nuclear material of the rules and regulations is a major part of this work, as it has been noted that the knowledge level of safeguarding nuclear material in many locations is very low. This paper will give a description of the work being performed by SSM to ensure that information related to the possession of nuclear material are gathered and correctly declared. It will give an overview of the different procedures that are applied to different categories of small holders in Sweden (where the differences are mostly due to historical reasons). It will also entail some of the challenges met along the way; such as explaining to radiographers that for nuclear non-proliferation purposes it is the shielding uranium container which is of interest, not the isotope emitting the radiation. What we have experienced being the major differences between collecting information from small holders as compared to larger nuclear facilities will also be outlined. The paper ends with an outline for future work.

  15. Pressure tube reactor

    International Nuclear Information System (INIS)

    Seki, Osamu; Kumasaka, Katsuyuki.

    1988-01-01

    Purpose: To remove the heat of reactor core using a great amount of moderators at the periphery of the reactor core as coolants. Constitution: Heat of a reactor core is removed by disposing a spontaneous recycling cooling device for cooling moderators in a moderator tank, without using additional power driven equipments. That is, a spontaneous recycling cooling device for cooling the moderators in the moderator tank is disposed. Further, the gap between the inner wall of a pressure tube guide pipe disposed through the vertical direction of a moderator tank and the outer wall of a pressure tube inserted through the guide pipe is made smaller than the rupture distortion caused by the thermal expansion upon overheating of the pressure tube and greater than the minimum gap required for heat shiels between the pressure tube and the pressure tube guide pipe during usual operation. In this way, even if such an accident as can not using a coolant cooling device comprising power driven equipment should occur in the pressure tube type reactor, the rise in the temperature of the reactor core can be retarded to obtain a margin with time. (Kamimura, M.)

  16. Methods for Sampling and Measurement of Compressed Air Contaminants

    Energy Technology Data Exchange (ETDEWEB)

    Stroem, L

    1976-10-15

    In order to improve the technique for measuring oil and water entrained in a compressed air stream, a laboratory study has been made of some methods for sampling and measurement. For this purpose water or oil as artificial contaminants were injected in thin streams into a test loop, carrying dry compressed air. Sampling was performed in a vertical run, down-stream of the injection point. Wall attached liquid, coarse droplet flow, and fine droplet flow were sampled separately. The results were compared with two-phase flow theory and direct observation of liquid behaviour. In a study of sample transport through narrow tubes, it was observed that, below a certain liquid loading, the sample did not move, the liquid remaining stationary on the tubing wall. The basic analysis of the collected samples was made by gravimetric methods. Adsorption tubes were used with success to measure water vapour. A humidity meter with a sensor of the aluminium oxide type was found to be unreliable. Oil could be measured selectively by a flame ionization detector, the sample being pretreated in an evaporation- condensation unit

  17. Methods for Sampling and Measurement of Compressed Air Contaminants

    International Nuclear Information System (INIS)

    Stroem, L.

    1976-10-01

    In order to improve the technique for measuring oil and water entrained in a compressed air stream, a laboratory study has been made of some methods for sampling and measurement. For this purpose water or oil as artificial contaminants were injected in thin streams into a test loop, carrying dry compressed air. Sampling was performed in a vertical run, down-stream of the injection point. Wall attached liquid, coarse droplet flow, and fine droplet flow were sampled separately. The results were compared with two-phase flow theory and direct observation of liquid behaviour. In a study of sample transport through narrow tubes, it was observed that, below a certain liquid loading, the sample did not move, the liquid remaining stationary on the tubing wall. The basic analysis of the collected samples was made by gravimetric methods. Adsorption tubes were used with success to measure water vapour. A humidity meter with a sensor of the aluminium oxide type was found to be unreliable. Oil could be measured selectively by a flame ionization detector, the sample being pretreated in an evaporation- condensation unit

  18. An in-tube radar for detecting cracks in metal tubing

    International Nuclear Information System (INIS)

    Caffey, Thurlow W. H.; Nassersharif, Bahram; Garcia, Gabe V.; Smith, Phillip R.; Jedlicka, Russell P.; Hensel, Edward C.

    2000-01-01

    A major cause of failures in heat exchangers and steam generators in nuclear power plants is degradation of the tubes within them. The tube failure is often caused by the development of cracks that begin on the outer surface of the tube and propagate both inwards and laterally. A new technique will be described for detection of defects using a continuous-wave radar device within metal tubing. The technique is 100% volumetric, and may find smaller defects, find them more rapidly, and find them less expensively than present methods. Because this project was started only recently, there is no demonstrated performance to report so far. However, the basic engineering concepts will be presented together with a description of the milestone tasks and dates

  19. The role of stake holders in the Italian debate on the national radioactive waste deposit

    International Nuclear Information System (INIS)

    Cantone, Marie C.

    2008-01-01

    Full text: In early 2003, following an increased concern about the international terrorist threat, the Italian Government declared an emergency status for national nuclear installations, and in particular for radioactive waste deposits. A working group of experts - mainly from the Society for the Management of Nuclear Installations (SOGIN) and the Agency for New Technologies, Energy and Environment (ENEA) - was appointed and charged with the analysis of the technical aspects implied in the creation of a repository to host permanently LLRW and MLRW as well as to host temporarily HLRW. In November 2003 the Italian Government passed a decree to authorize the creation of a national nuclear waste repository within a geological salt deposit in the territory of Scanzano Jonico, in the Basilicata Region. The decision was made without any negotiation with the local population and the authorities of Scanzano Jonico. The lack of transparent communication and the attempt to impose the project 'from the top' was perceived as a 'deceptive strategy'. The population of the entire region spontaneously organized a mass protest movement against the project; blockades were carried out on the major highway connecting Northern to Southern Italy and the controversy gained the attention of the national mass media. Two weeks later, the Italian government withdrew the decree. Presently, the Italian nuclear waste is distributed over more than 20 locations in 11 different Regions, and the creation of a national disposal site has been postponed. The present study aims at highlighting the reasons behind social conflicts on nuclear waste risks. We will examine the attitudes and the communication strategies of the different stake holders which took part in the public debate on the Italian nuclear waste dump. Drawing on methodologies used in media studies, we are carrying out a quantitative and qualitative analysis of the main national and local newspapers in order to draw a 'map' of the

  20. Expansion lyre-shaped tube

    International Nuclear Information System (INIS)

    Andro, Jean.

    1973-01-01

    The invention relates the expansion lyre-shaped tube portions formed in dudgeoned tubular bundles between two bottom plates. An expansion lyre comprises at least two sets of tubes of unequal lengths coplanar and symmetrical with respect to the main tube axis, with connecting portions between the tubes forming said sets. The invention applies to apparatus such as heat exchangers, heaters, superheaters or breeders [fr

  1. Steam generator tube failures

    International Nuclear Information System (INIS)

    MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

    1996-04-01

    A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service

  2. Investigation into the suitability of capillary tubes for microcrystalline testing.

    Science.gov (United States)

    Elie, Leonie E; Baron, Mark G; Croxton, Ruth S; Elie, Mathieu P

    2013-07-01

    A comparison between microcrystalline tests performed on microscope slides and flat capillary tubes with inner diameters ranging from 0.1 to 0.7 mm was carried out to explore the appropriateness of tubes for rapid testing of suspected drugs of abuse in the laboratory as well as in the field. Tests for mephedrone, cocaine, and phencyclidine were chosen as examples to investigate the handling of the capillary tubes, the influence on crystal habit, size, and the effects on the limit of detection. Image stacking software was used to increase the depth of field of micrographs taken from developed microcrystals greatly enhancing the interpretability even months after carrying out the microcrystalline test. Additionally, the potential of seeding capillary tubes with a reagent was studied. Pre-treatment of tubes would allow microcrystalline tests to be carried out quicker and anywhere without the necessity of taking along expensive and hazardous reagents. The sealing of capillary tubes containing developed microcrystalline tests in order to preserve results for a long period of time was successfully done by applying paraffin wax to the open ends. Finally, it was concluded that capillary tubes are suitable vessels for performing microcrystalline tests. The increased portability of the improved set-up allows tests to be safely executed outside laboratories without impairing the quality of the result. Findings were applied to six legal high samples purchased online between May and August 2011. The active ingredients like MDAI as well as cutting agents like caffeine were successfully identified using the microcrystalline test technique in capillary tubes. Copyright © 2012 John Wiley & Sons, Ltd.

  3. Prospects for stronger calandria tubes

    International Nuclear Information System (INIS)

    Ells, C.E.; Coleman, C.E.; Hosbons, R.R.; Ibrahim, E.F.; Doubt, G.L.

    1990-12-01

    The CANDU calandria tubes, made of seam welded and annealed Zircaloy-2, have given exemplary service in-reactor. Although not designed as a system pressure containment, calandria tubes may remain intact even in the face of pressure tube rupture. One such incident at Pickering Unit 2 demonstrated the economic advantage of such an outcome, and a case can be made for increasing the probability that other calandria tubes would perform in a similar fashion. Various methods of obtaining stronger calandria tubes are available, and reviewed here. When the tubes are internally pressurized, the weld is the weak section of the tube. Increasing the oxygen concentration in the starting sheet, and thickening the weld, are promising routes to a stronger tube

  4. Method and apparatus for sampling atmospheric mercury

    Science.gov (United States)

    Trujillo, Patricio E.; Campbell, Evan E.; Eutsler, Bernard C.

    1976-01-20

    A method of simultaneously sampling particulate mercury, organic mercurial vapors, and metallic mercury vapor in the working and occupational environment and determining the amount of mercury derived from each such source in the sampled air. A known volume of air is passed through a sampling tube containing a filter for particulate mercury collection, a first adsorber for the selective adsorption of organic mercurial vapors, and a second adsorber for the adsorption of metallic mercury vapor. Carbon black molecular sieves are particularly useful as the selective adsorber for organic mercurial vapors. The amount of mercury adsorbed or collected in each section of the sampling tube is readily quantitatively determined by flameless atomic absorption spectrophotometry.

  5. Sample vial inserts: A better approach for sampling heterogeneous slurry samples in the SRS Defense Waste Processing Facility

    International Nuclear Information System (INIS)

    Coleman, C.J.; Goode, S.R.

    1996-01-01

    A convenient and effective new approach for analyzing DWPF samples involves the use of inserts with volumes of 1.5--3 ml placed in the neck of 14 ml sample vials. The inserts have rims that conform to the rim of the vials so that they sit straight and stable in the vial. The DWPF tank sampling system fills the pre-weighed insert rather than the entire vial, so the vial functions only as the insert holder. The shielded cell operator then removes the vial cap and decants the insert containing the sample into a plastic bottle, crucible, etc., for analysis. Inert materials such as Teflon, plastic, and zirconium are used for the insert so it is unnecessary to separate the insert from the sample for most analyses. The key technique advantage of using inserts to take DWPF samples versus filling sample vials is that it provides a convenient and almost foolproof way of obtaining and handling small volumes of slurry samples in a shielded cell without corrupting the sample. Since the insert allows the entire sample to be analyzed, this approach eliminates the errors inherent with subsampling heterogeneous slurries that comprise DWPF samples. Slurry samples can then be analyzed with confidence. Analysis times are dramatically reduced by eliminating the drying and vitrification steps normally used to produce a homogeneous solid sample. Direct dissolution and elemental analysis of slurry samples are achieved in 8 hours or less compared with 40 hours for analysis of vitrified slurry samples. Comparison of samples taken in inserts versus full vials indicate that the insert does not significantly affect sample composition

  6. Fabrication of seamless calandria tubes

    International Nuclear Information System (INIS)

    Saibaba, N.; Phanibabu, C.; Bhaskara Rao, C.V.; Kalidas, R.; Ganguly, C.

    2002-01-01

    Full text: Calandria tube is a large diameter, thin walled zircaloy-4 tube and is an important structural component of PHWR type of reactors. These tubes are lifetime components and remain during the full life of the reactor. Calandria tubes are classified as extremely thin walled tubes with a diameter to wall thickness ratio of around 96. Such thin walled tubes are conventionally produced by seam welded route comprising of extrusion of slabs followed by a series of hot and rolling passes, shaping into O-shape and eventual welding. An alternative and superior method of fabricating the calandria tubes, the seamless route, has been developed, which involves hot extrusion of mother blanks followed by three successive cold pilger reductions. Eccentricity correction of the extruded blanks is carried out on a special purpose grinding equipment to bring the wall thickness variation within permissible limits. Predominant wall thickness reductions are given during cold pilgering to ensure high Q-factor values. The texture in the finished tubes could be closely, controlled with an average f r value of 0.65. Pilgering parameters and tube guiding system have been specially designed to facilities rolling of thin walled tubes. Seamless calandria tubes have distinct advantages over welded tubes. In addition to the absence of weld, they are dimensionally more stable, lighter in weight and possess uniform grains with superior grain size. The cycle time from billet to finished product is substantially reduced and the product is amenable to high level of quality assurance. The most significant feature of the seamless route is its material recovery over welded route. Residual stresses measured in the tubes indicate that these are negligible and uniform along the length of the tube. In view of their superior quality, the first charge of seamless calandria tubes will be rolled into the first 500 MWe Pressurised Heavy Water Reactor at Tarapur

  7. Method for shaping polyethylene tubing

    Science.gov (United States)

    Kramer, R. C.

    1981-01-01

    Method forms polyethylene plastic tubing into configurations previously only possible with metal tubing. By using polyethylene in place of copper or stain less steel tubing inlow pressure systems, fabrication costs are significantly reduced. Polyethylene tubing can be used whenever low pressure tubing is needed in oil operations, aircraft and space applications, powerplants, and testing laboratories.

  8. Design for a low temperature ion implantation and luminescence cryostat

    International Nuclear Information System (INIS)

    Noonan, J.R.; Kirkpatrick, C.G.; Myers, D.R.; Streetman, B.G.

    1976-01-01

    Several simple design changes of a conventional liquid helium optical Dewar can significantly improve the cryostat's versatility for use in low temperature particle irradiation. A bellows assembly provides precise sample positioning and allows convenient access for electrical connections. A heat exchanger consisting of thin walled tubing with a 'goose neck' bend provides a simple, effective means of cooling the sample as well as excellent thermal isolation of the sample holder from the coolant reservoir during controlled anneals. The addition of a vane-type vacuum valve, optical windows, and a rotatable tailpiece facilitates the study of optical properties of materials following low temperature ion implantation. (author)

  9. Pcl/Chitosan Blended Nanofibrous Tubes Made by Dual Syringe Electrospinning

    Directory of Open Access Journals (Sweden)

    Hild Martin

    2015-03-01

    Full Text Available 3D tubular scaffolds made from Poly-(Ɛ-caprolactone (PCL/chitosan (CS nanofibres are very promising candidate as vascular grafts in the field of tissue engineering. In this work, the fabrication of PCL/CS-blended nanofibrous tubes with small diameters by electrospinning from separate PCL and CS solutions is studied. The influence of different CS solutions (CS/polyethylene glycol (PEO/glacial acetic acid (AcOH, CS/trifluoroacetic acid (TFA, CS/ AcOH on fibre formation and producibility of nanofibrous tubes is investigated. Attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR is used to verify the presence of CS in the blended samples. Tensile testing and pore size measurements are done to underline the good prerequisites of the fabricated blended PCL/ CS nanofibrous tubes as potential scaffolds for vascular grafts. Tubes fabricated from the combination of PCL and CS dissolved in AcOH possesses properties, which are favourable for future cell culture studies.

  10. Field Air Sampling and Simultaneous Chemical and Sensory Analysis of Livestock Odorants with Sorbent Tube GC-MS/Olfactometry

    International Nuclear Information System (INIS)

    Zhang Shicheng; Cai Lingshuang; Koziel, Jacek A.; Hoff, Steven; Clanton, Charles; Schmidt, David; Jacobson, Larry; Parker, David; Heber, Albert

    2009-01-01

    Characterization and quantification of livestock odorants is one of the most challenging analytical tasks because odor-causing gases are very reactive, polar and often present at very low concentrations in a complex matrix of less important or irrelevant gases. The objective of this research was to develop a novel analytical method for characterization of the livestock odorants including their odor character, odor intensity, and hedonic tone and to apply this method for quantitative analysis of the key odorants responsible for livestock odor. Sorbent tubes packed with Tenax TA were used for field sampling. The automated one-step thermal desorption module coupled with multidimensional gas chromatography-mass spectrometry/olfactometry system was used for simultaneous chemical and odor analysis. Fifteen odorous VOCs and semi-VOCs identified from different livestock species operations were quantified. Method detection limits ranges from 40 pg for skatole to 3590 pg for acetic acid. In addition, odor character, odor intensity and hedonic tone associated with each of the target odorants are also analyzed simultaneously. We found that the mass of each VOCs in the sample correlates well with the log stimulus intensity. All of the correlation coefficients (R 2 ) are greater than 0.74, and the top 10 correlation coefficients were greater than 0.90.

  11. Whether power holders construe their power as responsibility or opportunity influences their tendency to take advice from others

    NARCIS (Netherlands)

    de Wit, F.R.C.; Scheepers, D.; Ellemers, N.; Sassenberg, Kai; Scholl, Annika

    Empirical evidence suggests that power elicits a generic tendency to disregard advice. We examined different responses power holders may show in their tendency to take advice depending on the construal of power. We report a field study and an experiment among managers and other powerful

  12. Heat Transfer Analysis of an Optimized, Flexible Holder System for Freeze-Drying in Dual Chamber Cartridges Using Different State-of-the-Art PAT Tools.

    Science.gov (United States)

    Korpus, Christoph; Pikal, Michael; Friess, Wolfgang

    2016-11-01

    The aim of this study was to determine the heat transfer characteristics of an optimized flexible holder device, using Tunable Diode Laser Absorption Spectroscopy, the Pressure Rise Test, and the gravimetric procedure. Two different controlled nucleation methods were tested, and an improved sublimation process, "preheated plate," was developed. Tunable Diode Laser Absorption Spectroscopy identified an initial sublimation burst phase. Accordingly, steady-state equations were adapted for the gravimetric procedure, to account for this initial non-steady-state period. The heat transfer coefficient, K DCC , describing the transfer from the holder to the DCC, was the only heat transfer coefficient showing a clear pressure dependence with values ranging from 3.81E-04 cal/(g·cm 2 ·K) at 40 mTorr to 7.38E-04 cal/(g·cm 2 ·K) at 200 mTorr. The heat transfer coefficient, K tot , reflecting the overall energy transfer via the holder, increased by around 24% from 40 to 200 mTorr. This resulted in a pressure-independent sublimation rate of around 42 ± 1.06 mg/h over the whole pressure range. Hence, this pressure-dependent increase in energy transfer completely compensated the decrease in driving force of sublimation. The "flexible holder" shows a substantially reduced impact of atypical radiation, improved drying homogeneity, and ultimately a better transferability of the freeze-drying cycle for process optimization. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  13. Spring/dimple instrument tube restraint

    International Nuclear Information System (INIS)

    DeMario, E.E.; Lawson, C.N.

    1993-01-01

    A nuclear fuel assembly for a pressurized water nuclear reactor has a spring and dimple structure formed in a non-radioactive insert tube placed in the top of a sensor receiving instrumentation tube thimble disposed in the fuel assembly and attached at a top nozzle, a bottom nozzle, and intermediate grids. The instrumentation tube thimble is open at the top, where the sensor or its connection extends through the cooling water for coupling to a sensor signal processor. The spring and dimple insert tube is mounted within the instrumentation tube thimble and extends downwardly adjacent the top. The springs and dimples restrain the sensor and its connections against lateral displacement causing impact with the instrumentation tube thimble due to the strong axial flow of cooling water. The instrumentation tube has a stainless steel outer sleeve and a zirconium alloy inner sleeve below the insert tube adjacent the top. The insert tube is relatively non-radioactivated inconel alloy. The opposed springs and dimples are formed on diametrically opposite inner walls of the insert tube, the springs being formed as spaced axial cuts in the insert tube, with a web of the insert tube between the cuts bowed radially inwardly for forming the spring, and the dimples being formed as radially inward protrusions opposed to the springs. 7 figures

  14. Tube bundle system: for monitoring of coal mine atmosphere.

    Science.gov (United States)

    Zipf, R Karl; Marchewka, W; Mohamed, K; Addis, J; Karnack, F

    2013-05-01

    A tube bundle system (TBS) is a mechanical system for continuously drawing gas samples through tubes from multiple monitoring points located in an underground coal mine. The gas samples are drawn via vacuum pump to the surface and are typically analyzed for oxygen, methane, carbon dioxide and carbon monoxide. Results of the gas analyses are displayed and recorded for further analysis. Trends in the composition of the mine atmosphere, such as increasing methane or carbon monoxide concentration, can be detected early, permitting rapid intervention that prevents problems, such as a potentially explosive atmosphere behind seals, fire or spontaneous combustion. TBS is a well-developed technology and has been used in coal mines around the world for more than 50 years. Most longwall coal mines in Australia deploy a TBS, usually with 30 to 40 monitoring points as part of their atmospheric monitoring. The primary uses of a TBS are detecting spontaneous combustion and maintaining sealed areas inert. The TBS might also provide mine atmosphere gas composition data after a catastrophe occurs in an underground mine, if the sampling tubes are not damaged. TBSs are not an alternative to statutory gas and ventilation airflow monitoring by electronic sensors or people; rather, they are an option to consider in an overall mine atmosphere monitoring strategy. This paper describes the hardware, software and operation of a TBS and presents one example of typical data from a longwall coal mine.

  15. Performance of pressure tubes in CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Rodgers, D.; Griffiths, M.; Bickel, G.; Buyers, A.; Coleman, C.; Nordin, H.; St Lawrence, S. [Canadian Nuclear Laboratories, Chalk River, Ontario (Canada)

    2016-06-15

    The pressure tubes in CANDU reactors typically operate for times up to about 30 years prior to refurbishment. The in-reactor performance of Zr-2.5Nb pressure tubes has been evaluated by sampling and periodic inspection. This paper describes the behavior and discusses the factors controlling the behaviour of these components. The Zr–2.5Nb pressure tubes are nominally extruded at 815{sup o}C, cold worked nominally 27%, and stress relieved at 400 {sup o}C for 24 hours, resulting in a structure consisting of elongated grains of hexagonal close-packed alpha-Zr, partially surrounded by a thin network of filaments of body-centred-cubic beta-Zr. These beta-Zr filaments are meta-stable and contain about 20% Nb after extrusion. The stress-relief treatment results in partial decomposition of the beta-Zr filaments with the formation of hexagonal close-packed alpha-phase particles that are low in Nb, surrounded by a Nb-enriched beta-Zr matrix. The material properties of pressure tubes are determined by variations in alpha-phase texture, alpha-phase grain structure, network dislocation density, beta-phase decomposition, and impurity concentration that are a function of manufacturing variables. The pressure tubes operate at temperatures between 250 {sup o}C and 310 {sup o}C with coolant pressures up to about 11 MPa in fast neutron fluxes up to 4 x 10{sup 17} n·m{sup -2}·s{sup -1} (E > 1 MeV) and the properties are modified by these conditions. The properties of the pressure tubes in an operating reactor are therefore a function of both manufacturing and operating condition variables. The ultimate tensile strength, fracture toughness, and delayed hydride-cracking properties (velocity (V) and threshold stress intensity factor (K{sub IH})) change with irradiation, but all reach a nearly limiting value at a fluence of less than 10{sup 25} n·m{sup -2} (E > 1 MeV). At this point the ultimate tensile strength is raised about 200 MPa, toughness is reduced by about 50%, V increases

  16. Astrobiology Training in Lava Tubes (ATiLT): Characterizing coralloid speleothems in basaltic lava tubes as a Mars analogue

    Science.gov (United States)

    Ni, J.; Leveille, R. J.; Douglas, P.

    2017-12-01

    Coralloid speleothems or cave corals are small mineralised nodes that can take a variety of forms, and which develop through groundwater seepage and water-rock interaction in caves. They are found commonly on Earth in a plethora of caves, including lava tubes. Since lava tubes have been identified on the surface of Mars from remotely sensed images, there has been interest in studying Earth's lava tube systems as an analogue for understanding Martian lava environments. If cave minerals were found on Mars, they could indicate past or present water-rock interaction in the Martian subsurface. Martian lava tubes could also provide insights into habitable subsurface environments as well as conditions favourable for the synthesis and preservation of biosignatures. One of the aims of the Astrobiology Training in Lava Tubes (ATiLT) project is to analyze biosignatures and paleoenvironmental indicators in secondary cave minerals, which will be looked at in-situ and compared to collected field samples. In this study, secondary mineralization in lava cave systems from Lava Beds National Monument, CA is examined. In the field, coralloid speleothems have been observed growing on all surfaces of the caves, including cave ceilings, floors, walls and overhangs. They are also observed growing adjacent to biofilms, which sometimes fill in the cracks of the coralloid nodes. Preliminary results show the presence of opal, calcite, quartz and other minor minerals in the speleothems. This study seeks to understand the formation mechanism and source of these secondary minerals, as well as determine their possible relation to the biofilms. This will be done through the analysis of the water chemistry, isotope geochemistry and microscale mineralogy.

  17. Design optimization of hydraulic turbine draft tube based on CFD and DOE method

    Science.gov (United States)

    Nam, Mun chol; Dechun, Ba; Xiangji, Yue; Mingri, Jin

    2018-03-01

    In order to improve performance of the hydraulic turbine draft tube in its design process, the optimization for draft tube is performed based on multi-disciplinary collaborative design optimization platform by combining the computation fluid dynamic (CFD) and the design of experiment (DOE) in this paper. The geometrical design variables are considered as the median section in the draft tube and the cross section in its exit diffuser and objective function is to maximize the pressure recovery factor (Cp). Sample matrixes required for the shape optimization of the draft tube are generated by optimal Latin hypercube (OLH) method of the DOE technique and their performances are evaluated through computational fluid dynamic (CFD) numerical simulation. Subsequently the main effect analysis and the sensitivity analysis of the geometrical parameters of the draft tube are accomplished. Then, the design optimization of the geometrical design variables is determined using the response surface method. The optimization result of the draft tube shows a marked performance improvement over the original.

  18. Development of a versatile TEM specimen holder for the characterization of photocatalytic materials

    DEFF Research Database (Denmark)

    Cavalca, Filippo; Langhammer, C.; Hansen, Thomas Willum

    2011-01-01

    conventional TEM analysis on photocatalysts with several in situ TEM techniques including environmental TEM (ETEM), in situ photo activation and localized surface plasmon resonance (LSPR) spectroscopy [3-4]. These experiments are facilitated by the construction of a specimen holder capable of illuminating....../on nanomaterials and thin films. We present results from combined ETEM-LSPR studies of thermally-induced catalytic phenomena and on metal nanoparticle sintering, an important process in catalysis, which we study in situ in both real and model systems by means of indirect nanoplasmonic sensing and ETEM....

  19. Intercostal drainage tube or intracardiac drainage tube?

    Science.gov (United States)

    Anitha, N; Kamath, S Ganesh; Khymdeit, Edison; Prabhu, Manjunath

    2016-01-01

    Although insertion of chest drain tubes is a common medical practice, there are risks associated with this procedure, especially when inexperienced physicians perform it. Wrong insertion of the tube has been known to cause morbidity and occasional mortality. We report a case where the left ventricle was accidentally punctured leading to near-exsanguination. This report is to highlight the need for experienced physicians to supervise the procedure and train the younger physician in the safe performance of the procedure.

  20. Sample preparation for the HAW project and experimental results from the HFR

    International Nuclear Information System (INIS)

    Garcia Celma, A.; Wees, H. van; Miralles, L.

    1990-09-01

    This report deals with the preparation and analysis of samples, during the period May 1989-November 1989, for the High-Active Waste (HAW) project, a large-scale in situ test being performed underground in the Asse salt mine, Remlingen FRG. The development of the technical procedures required, and the scientific results, which regard mostly characterization of Potasas del Llobregat sample, are reported. Prior to using the samples in both the H.A.W. and the H.F.R. experiments they have to be machined to fit their holders. Technical improvements for machining samples of salt are reported. (H.W.). 9 refs.; 68 figs.; 10 tabs

  1. Optimization and evaluation of multi-bed adsorbent tube method in collection of volatile organic compounds

    Science.gov (United States)

    Ho, Steven Sai Hang; Wang, Liqin; Chow, Judith C.; Watson, John G.; Xue, Yonggang; Huang, Yu; Qu, Linli; Li, Bowei; Dai, Wenting; Li, Lijuan; Cao, Junji

    2018-04-01

    The feasibility of using adsorbent tubes to collect volatile organic compounds (VOCs) has been demonstrated since the 1990's and standardized as Compendium Method TO-17 by the U.S. Environmental Protection Agency (U.S EPA). This paper investigates sampling and analytical variables on concentrations of 57 ozone (O3) precursors (C2-C12 aliphatic and aromatic VOCs) specified for the Photochemical Assessment Monitoring Station (PAMS). Laboratory and field tests examined multi-bed adsorbent tubes containing a sorbate combination of Tenax TA, Carbograph 1 TD, and Carboxen 1003. Analyte stabilities were influenced by both collection tube temperature and ambient O3 concentrations. Analytes degraded during storage, while blank levels were elevated by passive adsorption. Adsorbent tube storage under cold temperatures (- 10 °C) in a preservation container filled with solid silica gel and anhydrous calcium sulfate (CaSO4) ensured sample integrity. A high efficiency (> 99%) O3 scrubber (i.e., copper coil tube filled with saturated potassium iodide [KI]) removed O3 (i.e., air stream with a sampling capacity of 30 h. Water vapor scrubbers interfered with VOC measurements. The optimal thermal desorption-gas chromatography/mass spectrometry (TD-GC/MS) desorption time of 8 min was found at 330 °C. Good linearity (R2 > 0.995) was achieved for individual analyte calibrations (with the exception of acetylene) for mixing ratios of 0.08-1.96 ppbv. The method detection limits (MDLs) were below 0.055 ppbv for a 3 L sample volume. Replicate analyses showed relative standard deviations (RSDs) of < 10%, with the majority of the analytes within < 5%.

  2. Thermal characterization of rods, tubes and spheres using pulsed infrared thermography

    International Nuclear Information System (INIS)

    Apinaniz, E; Mendioroz, A; Madariaga, N; Oleaga, A; Celorrio, R; Salazar, A

    2008-01-01

    In this work we analyse the accuracy of an extension of the flash method to measure the thermal diffusivity of rods, tubes and spheres, which was recently proposed by the authors. We have performed measurements in a wide set of calibrated samples of different sizes and we have found that a lower limiting size of the radius can be established for the validity of the method. On the other hand, a procedure to retrieve the thermal conductivity of tubes, based on filling them with a contrast liquid (water), is proposed. Moreover, the thermal contact resistance between the two layers of coated cylinders is also obtained. Measurements on calibrated samples confirm the validity of the two latest methods

  3. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home >> NEI YouTube Videos >> NEI YouTube Videos: Amblyopia Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract ...

  4. Specimen holder for an electron microscope and device and method for mounting a specimen in an electron microscope

    NARCIS (Netherlands)

    Zandbergen, H.W.; Latenstein van Voorst, A.; Westra, C.; Hoveling, G.H.

    1996-01-01

    A specimen holder for an electron microscope, comprising a bar-shaped body provided adjacent one end with means for receiving a specimen, with means being present for screening the specimen from the environment at least temporarily in airtight and moisture-proof manner in a first position, which

  5. Impact of Small Holder Dairy Farm on the Air Quality in Gunungpati District, Semarang Municipality

    Science.gov (United States)

    Widiastuti, E.; Kustono; Adiarto; Nurliyani; Sugiharto, S.

    2018-02-01

    The study aimed to investigate the impact of small holder dairy farm on the air quality in the farm and surrounding area. The study was conducted in three farmer groups in the District of Gunungpati, including the farmer groups in the villages of Nangkasawit, Plalangan and Sumurejo. Samplings of air quality were conducted in four points (locations), i.e., inside the barn, 100 m, 200 m and 300 m from the area of farm. Parameters observed were emission of NH3 CO2, H2S and CH4. Results showed that the levels of NH3 in the barn, 100 m, 200 m and 300 m from the farm area in Nangkasawit village were 0.211, 0.107, 0.104 and 0,035 ppm, respectively. The levels of NH3 in Plalangan village were 0.289, 0.231, 0.13 and 0.108 ppm, respectively, and in Sumurejo village were 0.109, 0.110, 0.082 and 0.046 ppm, respectively. The levels of H2S in Nangkasawit, Plalangan and Sumurejo villages at the entire points of observations were air quality was better (lower contamination) with the farther distance of locations from the barn.

  6. Portrayal of Smokeless Tobacco in YouTube Videos

    Science.gov (United States)

    Augustson, Erik M.; Backinger, Cathy L.

    2012-01-01

    Objectives: Videos of smokeless tobacco (ST) on YouTube are abundant and easily accessible, yet no studies have examined the content of ST videos. This study assesses the overall portrayal, genre, and messages of ST YouTube videos. Methods: In August 2010, researchers identified the top 20 search results on YouTube by “relevance” and “view count” for the following search terms: “ST,” “chewing tobacco,” “snus,” and “Skoal.” After eliminating videos that were not about ST (n = 26), non-English (n = 14), or duplicate (n = 42), a final sample of 78 unique videos was coded for overall portrayal, genre, and various content measures. Results: Among the 78 unique videos, 15.4% were anti-ST, while 74.4% were pro-ST. Researchers were unable to determine the portrayal of ST in the remaining 10.3% of videos because they involved excessive or “sensationalized” use of the ST, which could be interpreted either positively or negatively, depending on the viewer. The most common ST genre was positive video diaries (or “vlogs”), which made up almost one third of the videos (29.5%), followed by promotional advertisements (20.5%) and anti-ST public service announcements (12.8%). While YouTube is intended for user-generated content, 23.1% of the videos were created by professional organizations. Conclusions: These results demonstrate that ST videos on YouTube are overwhelmingly pro-ST. More research is needed to determine who is viewing these ST YouTube videos and how they may affect people’s knowledge, attitudes, and behaviors regarding ST use. PMID:22080585

  7. Double wall steam generator tubing

    International Nuclear Information System (INIS)

    Padden, T.R.; Uber, C.F.

    1983-01-01

    Double-walled steam generator tubing for the steam generators of a liquid metal cooled fast breeder reactor prevents sliding between the surfaces due to a mechanical interlock. Forces resulting from differential thermal expansion between the outer tube and the inner tube are insufficient in magnitude to cause shearing of base metal. The interlock is formed by jointly drawing the tubing, with the inside wall of the outer tube being already formed with grooves. The drawing causes the outer wall of the inner tube to form corrugations locking with the grooves. (author)

  8. Learning from YouTube [Video Book

    Science.gov (United States)

    Juhasz, Alexandra

    2011-01-01

    YouTube is a mess. YouTube is for amateurs. YouTube dissolves the real. YouTube is host to inconceivable combos. YouTube is best for corporate-made community. YouTube is badly baked. These are a few of the things Media Studies professor Alexandra Juhasz (and her class) learned about YouTube when she set out to investigate what actually happens…

  9. [Effect of Parasep® feces centrifuge tube method on detecting schistosome eggs].

    Science.gov (United States)

    Ma, Nian; Zhang, Hua-ming; Liu, Xiong; Xiao, Chuan-yun; Wen, Xiao-hong; Li, Xia; Dong, Li-chun; Cui, Cai-xia; Tu, Zu-wu

    2014-08-01

    To evaluate the effect of the Parasep® feces centrifuge tube method on detecting schistosome eggs. A total of 803 residents aged from 6-65 years were selected in 2 schistosomiasis endemic villages, Jiangling County, Hubei Province, and their stool samples were collected and detected parallelly by the Kato-Katz technique, nylon silk egg hatching method, and Parasep® feces centrifuge tube method at the same time. Among the 803 people, 15 cases were found of schistosome egg positive, and the positive rate was 1.87%. The positive rates of the Kato-Katz technique, nylon silk egg hatching method, and Parasep® feces centrifuge tube method were 0.75%, 1.49% and 1.12%, respectively. The schistosome eggs got with the Parasep® feces centrifuge tube method were clear and easy to identify. In low endemic areas of schistosomiasis, the Parasep® feces centrifuge tube method can be used as schistosomiasis japonica etiology diagnosis method.

  10. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home » NEI YouTube Videos » NEI YouTube Videos: Amblyopia Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract ...

  11. Heat transfer performance during in-tube condensation in horizontal smooth, micro-fin and herringbone tubes

    OpenAIRE

    2008-01-01

    M.Ing. An experimental investigation was conducted into the heat transfer characteristics of horizontal smooth, micro-fin and herringbone tubes during in-tube condensation. The study focused on the heat transfer coefficients of refrigerants R-22, R-134a and R-407C inside the three tubes. The herringbone tube results were compared to the smooth and micro-fin tube results. The average increase in the heat transfer coefficient when compared to the smooth tube was found to be as high as 322% w...

  12. Plugging criteria for steam generator tubes with axial cracks near tube support plates

    International Nuclear Information System (INIS)

    Mattar Neto, Miguel

    2000-01-01

    Stress corrosion cracking with intergranular attack occurs on the secondary side of steam generator (SG) tubes where impurities concentrate due to boiling under restricted flow conditions. In the most of cases, it can be called ODSCC (Outer Diameter Stress Corrosion Cracking). The typical locations are areas near support plates, in sludge piles and at top of tubesheet crevices. Though it can also occur on free spans under the relatively thin deposits that build up on the tube surfaces. ODSCC near tube plate supports have been the cause of plugging of many tubes. Thus, studies on SG tubes plugging criteria related to this degradation mechanism are presented in this paper. Th purpose is to avoid unnecessary tube plugging from either safety or reliability standpoint. Based on these studies some conclusions on the plugging criteria and on the difficulties to apply them are addressed. (author)

  13. Brittle-fracture potential of irradiated Zircaloy-2 pressure tubes

    Science.gov (United States)

    Huang, F. H.

    1993-12-01

    Neutron irradiation can degrade the fracture toughness of Zircaloy-2 and may cause highly irradiated reactor components of this material to fail in a brittle manner. The effects of radiation embrittlement on the structural integrity of N Reactor pressure tubes are studied by performing KIc and JIc fracture toughness testing on samples cut from the Zircaloy-2 tubes periodically removed from the reactor. A fluence of 6 × 10 25n/ m2 ( E > 1 MeV) reduced the fracture toughness of the material by 40 to 50%. The fracture toughness values appear to saturate at 260°C with fluences above 3 × 10 25n/ m2 ( E > 1 MeV), but continue to decline with increasing fluence at temperatures below 177°C. Present and previous results obtained from irradiated pressure tubes indicate that the brittle-fracture potential of Zircaloy-2 increases with decreasing temperature and increasing fluence. Fractographic examinations of the fracture surfaces of irradiated samples reveal that circumferential hydride formation significantly influenced fracture morphology by providing sites for easy crack nucleation and leaving deep cracks. However, the deep cracks created at the hydride platelets in specimens containing less than 220 ppm hydrogen are not believed to be the major cause of degradation in postirradiation fracture toughness.

  14. Iodine induced stress corrosion cracking of zircaloy cladding tubes

    International Nuclear Information System (INIS)

    Brunisholz, L.; Lemaignan, C.

    1984-01-01

    Iodine is considered as one of the major fission products responsible for PCI failure of Zry cladding by stress corrosion cracking (SCC). Usual analysis of SCC involves both initiation and growth as sequential processes. In order to analyse initiation and growth independently and to be able to apply the procedures of fracture mechanics to the design of cladding, with respect to SCC, stress corrosion tests of Zry cladding tubes were undertaken with a small fatigue crack (approx. 200 μm) induced in the inner wall of each tube before pressurization. Details are given on the techniques used to induce the fatigue crack, the pressurization test procedure and the results obtained on stress releaved or recrystallized Zry 4 tubings. It is shown that the Ksub(ISCC) values obtained during these experiments are in good agreement with those obtained from large DCB fracture mechanics samples. Conclusions will be drawn on the applicability of linear elastic fracture mechanics (LEFM) to cladding design and related safety analysis. The work now underway is aimed at obtaining better understanding of the initiation step. It includes the irradiation of Zry samples with heavy ions to simulate the effect of recoil fragments implanted in the inner surface of the cladding, that could create a brittle layer of about 10 μm

  15. Intercostal drainage tube or intracardiac drainage tube?

    Directory of Open Access Journals (Sweden)

    N Anitha

    2016-01-01

    Full Text Available Although insertion of chest drain tubes is a common medical practice, there are risks associated with this procedure, especially when inexperienced physicians perform it. Wrong insertion of the tube has been known to cause morbidity and occasional mortality. We report a case where the left ventricle was accidentally punctured leading to near-exsanguination. This report is to highlight the need for experienced physicians to supervise the procedure and train the younger physician in the safe performance of the procedure.

  16. Determinants of Increasing Duration of First Unemployment among First Degree Holders in Rwanda: A Logistic Regression Analysis

    Science.gov (United States)

    Niragire, François; Nshimyiryo, Alphonse

    2017-01-01

    Unexpectedly, the duration of first unemployment among first degree holders has quickly increased in Rwanda after considerable loss of the skilled labour during the war and Genocide perpetrated against Tutsi in 1994. The time it takes a higher education graduate to land a first employment is a key indicator for the evaluation of and optimal…

  17. A comparison of fluoride-oxalate and plain (serum gel) tube on ...

    African Journals Online (AJOL)

    A continuing problem in the accurate measurement of glucose is its decline in concentration due to erythrocytic glycolysis after sampling, transport and processing. Eliminating this problem requires the use of an anti-glycolytic agent that can be added to the sampling tubes without altering cellular integrity while measuring ...

  18. Condensate subcooling near tube exit during horizontal in-tube condensation

    International Nuclear Information System (INIS)

    Hashizume, K.; Abe, N.; Ozeki, T.

    1992-01-01

    In-tube condensation is encountered in various applications for heat exchangers, such as domestic air-conditioning equipment, industrial air-cooled condensers, and moisture separator reheaters (MSRs) for nuclear power pants. Numerous research work has been conducted to predict the condensation heat transfer coefficient, and we have now enough information for thermal design of heat exchangers with horizontal in-tube condensation. Most of the research is analytical and/or experimental work in the annular or stratified flow regime, or experimental work on bulk condensation, i.e., from saturated vapor to complete condensation. On the other hand, there exist few data about the heat transfer phenomena in the very lower-quality region near the tube exit. The purpose of this paper is to clarify the condensation heat transfer phenomena near the tube exit experimentally and analytically, and to predict the degree of condensate subcooling

  19. Electroplating of nanostructured polyaniline-polypyrrole composite coating in a stainless-steel tube for on-line in-tube solid phase microextraction.

    Science.gov (United States)

    Asiabi, Hamid; Yamini, Yadollah; Seidi, Shahram; Esrafili, Ali; Rezaei, Fatemeh

    2015-06-05

    In this work, a novel and efficient on-line in-tube solid phase microextraction method followed by high performance liquid chromatography was developed for preconcentration and determination of trace amounts of parabens. A nanostructured polyaniline-polypyrrole composite was electrochemically deposited on the inner surface of a stainless steel tube and used as the extraction phase. Several important factors that influence the extraction efficiency, including type of solid-phase coating, extraction and desorption times, flow rates of the sample solution and eluent, pH, and ionic strength of the sample solution were investigated and optimized. Under the optimal conditions, the limits of detection were in the range of 0.02-0.04 μg L(-1). This method showed good linearity for parabens in the range of 0.07-50 μg L(-1), with coefficients of determination better than 0.998. The intra- and inter-assay precisions (RSD%, n=3) were in the range of 5.9-7.0% and 4.4-5.7% at three concentration levels of 2, 10, and 20 μg L(-1), respectively. The extraction recovery values for the spiked samples were in the acceptable range of 80.3-90.2%. The validated method was successfully applied for analysis of methyl-, ethyl-, and propyl parabens in some water, milk, and juice samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Microdischarges in DC accelerator tubes

    International Nuclear Information System (INIS)

    Eastham, D.A.; Thorn, R.

    1978-07-01

    Voltage tests on the Daresbury ceramic/titanium accelerator tube have shown that microdischarges play an important role in the conditioning process. It has been found that the voltage onset for microdischarges in a tube is dependent on the surface contamination of the electrodes and the tube geometry (in particular the tube length). This geometrical effect can be related to the trajectories of secondary ions emitted from the electrode surfaces. Sensitive diagnostic techniques have been developed to study the mass and energy distribution of ions emitted along the axis of the tube during these predischarges. The energy distribution of protons (and H - ions) can be related to the origins of the discharges in the tube. Detailed results are presented for a particular tube geometry. (author)