WorldWideScience

Sample records for sample storage time

  1. Effects of Long-Term Storage Time and Original Sampling Month on Biobank Plasma Protein Concentrations

    Directory of Open Access Journals (Sweden)

    Stefan Enroth

    2016-10-01

    Full Text Available The quality of clinical biobank samples is crucial to their value for life sciences research. A number of factors related to the collection and storage of samples may affect the biomolecular composition. We have studied the effect of long-time freezer storage, chronological age at sampling, season and month of the year and on the abundance levels of 108 proteins in 380 plasma samples collected from 106 Swedish women. Storage time affected 18 proteins and explained 4.8–34.9% of the observed variance. Chronological age at sample collection after adjustment for storage-time affected 70 proteins and explained 1.1–33.5% of the variance. Seasonal variation had an effect on 15 proteins and month (number of sun hours affected 36 proteins and explained up to 4.5% of the variance after adjustment for storage-time and age. The results show that freezer storage time and collection date (month and season exerted similar effect sizes as age on the protein abundance levels. This implies that information on the sample handling history, in particular storage time, should be regarded as equally prominent covariates as age or gender and need to be included in epidemiological studies involving protein levels.

  2. Air exposure and sample storage time influence on hydrogen release from tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Moshkunov, K.A., E-mail: moshkunov@gmail.co [National Research Nuclear University ' MEPhI' , Kashirskoe sh. 31, 115409 Moscow (Russian Federation); Schmid, K.; Mayer, M. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Boltzmannstrasse 2, D-85748 Garching (Germany); Kurnaev, V.A.; Gasparyan, Yu.M. [National Research Nuclear University ' MEPhI' , Kashirskoe sh. 31, 115409 Moscow (Russian Federation)

    2010-09-30

    In investigations of hydrogen retention in first wall components the influence of the conditions of the implanted target storage prior to analysis and the storage time is often neglected. Therefore we have performed a dedicated set of experiments. The release of hydrogen from samples exposed to ambient air after irradiation was compared to samples kept in vacuum. For air exposed samples significant amounts of HDO and D{sub 2}O are detected during TDS. Additional experiments have shown that heavy water is formed by recombination of releasing D and H atoms with O on the W surface. This water formation can alter hydrogen retention results significantly, in particular - for low retention cases. In addition to the influence of ambient air exposure also the influence of storage time in vacuum was investigated. After implantation at 300 K the samples were stored in vacuum for up to 1 week during which the retained amount decreased significantly. The subsequently measured TDS spectra showed that D was lost from both the high and low energy peaks during storage at ambient temperature of {approx}300 K. An attempt to simulate this release from both peaks during room temperature storage by TMAP 7 calculations showed that this effect cannot be explained by conventional diffusion/trapping models.

  3. Air exposure and sample storage time influence on hydrogen release from tungsten

    International Nuclear Information System (INIS)

    Moshkunov, K.A.; Schmid, K.; Mayer, M.; Kurnaev, V.A.; Gasparyan, Yu.M.

    2010-01-01

    In investigations of hydrogen retention in first wall components the influence of the conditions of the implanted target storage prior to analysis and the storage time is often neglected. Therefore we have performed a dedicated set of experiments. The release of hydrogen from samples exposed to ambient air after irradiation was compared to samples kept in vacuum. For air exposed samples significant amounts of HDO and D 2 O are detected during TDS. Additional experiments have shown that heavy water is formed by recombination of releasing D and H atoms with O on the W surface. This water formation can alter hydrogen retention results significantly, in particular - for low retention cases. In addition to the influence of ambient air exposure also the influence of storage time in vacuum was investigated. After implantation at 300 K the samples were stored in vacuum for up to 1 week during which the retained amount decreased significantly. The subsequently measured TDS spectra showed that D was lost from both the high and low energy peaks during storage at ambient temperature of ∼300 K. An attempt to simulate this release from both peaks during room temperature storage by TMAP 7 calculations showed that this effect cannot be explained by conventional diffusion/trapping models.

  4. Air exposure and sample storage time influence on hydrogen release from tungsten

    Science.gov (United States)

    Moshkunov, K. A.; Schmid, K.; Mayer, M.; Kurnaev, V. A.; Gasparyan, Yu. M.

    2010-09-01

    In investigations of hydrogen retention in first wall components the influence of the conditions of the implanted target storage prior to analysis and the storage time is often neglected. Therefore we have performed a dedicated set of experiments. The release of hydrogen from samples exposed to ambient air after irradiation was compared to samples kept in vacuum. For air exposed samples significant amounts of HDO and D 2O are detected during TDS. Additional experiments have shown that heavy water is formed by recombination of releasing D and H atoms with O on the W surface. This water formation can alter hydrogen retention results significantly, in particular - for low retention cases. In addition to the influence of ambient air exposure also the influence of storage time in vacuum was investigated. After implantation at 300 K the samples were stored in vacuum for up to 1 week during which the retained amount decreased significantly. The subsequently measured TDS spectra showed that D was lost from both the high and low energy peaks during storage at ambient temperature of ˜300 K. An attempt to simulate this release from both peaks during room temperature storage by TMAP 7 calculations showed that this effect cannot be explained by conventional diffusion/trapping models.

  5. Simple DNA extraction of urine samples: Effects of storage temperature and storage time.

    Science.gov (United States)

    Ng, Huey Hian; Ang, Hwee Chen; Hoe, See Ying; Lim, Mae-Lynn; Tai, Hua Eng; Soh, Richard Choon Hock; Syn, Christopher Kiu-Choong

    2018-06-01

    Urine samples are commonly analysed in cases with suspected illicit drug consumption. In events of alleged sample mishandling, urine sample source identification may be necessary. A simple DNA extraction procedure suitable for STR typing of urine samples was established on the Promega Maxwell ® 16 paramagnetic silica bead platform. A small sample volume of 1.7mL was used. Samples were stored at room temperature, 4°C and -20°C for 100days to investigate the influence of storage temperature and time on extracted DNA quantity and success rate of STR typing. Samples stored at room temperature exhibited a faster decline in DNA yield with time and lower typing success rates as compared to those at 4°C and -20°C. This trend can likely be attributed to DNA degradation. In conclusion, this study presents a quick and effective DNA extraction protocol from a small urine volume stored for up to 100days at 4°C and -20°C. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Effect of sample storage time on detection of hybridization signals in Checkerboard DNA-DNA hybridization.

    Science.gov (United States)

    do Nascimento, Cássio; Muller, Katia; Sato, Sandra; Albuquerque Junior, Rubens Ferreira

    2012-04-01

    Long-term sample storage can affect the intensity of the hybridization signals provided by molecular diagnostic methods that use chemiluminescent detection. The aim of this study was to evaluate the effect of different storage times on the hybridization signals of 13 bacterial species detected by the Checkerboard DNA-DNA hybridization method using whole-genomic DNA probes. Ninety-six subgingival biofilm samples were collected from 36 healthy subjects, and the intensity of hybridization signals was evaluated at 4 different time periods: (1) immediately after collecting (n = 24) and (2) after storage at -20 °C for 6 months (n = 24), (3) for 12 months (n = 24), and (4) for 24 months (n = 24). The intensity of hybridization signals obtained from groups 1 and 2 were significantly higher than in the other groups (p  0.05). The Checkerboard DNA-DNA hybridization method was suitable to detect hybridization signals from all groups evaluated, and the intensity of signals decreased significantly after long periods of sample storage.

  7. Effect of Sample Storage Temperature and Time Delay on Blood Gases, Bicarbonate and pH in Human Arterial Blood Samples.

    Science.gov (United States)

    Mohammadhoseini, Elham; Safavi, Enayat; Seifi, Sepideh; Seifirad, Soroush; Firoozbakhsh, Shahram; Peiman, Soheil

    2015-03-01

    Results of arterial blood gas analysis can be biased by pre-analytical factors, such as time interval before analysis, temperature during storage and syringe type. To investigate the effects of samples storage temperature and time delay on blood gases, bicarbonate and PH results in human arterial blood samples. 2.5 mL arterial blood samples were drawn from 45 patients via an indwelling Intraarterial catheter. Each sample was divided into five equal samples and stored in multipurpose tuberculin plastic syringes. Blood gas analysis was performed on one of five samples as soon as possible. Four other samples were divided into two groups stored at 22°C and 0°C. Blood gas analyses were repeated at 30 and 60 minutes after sampling. PaO2 of the samples stored at 0°C was increased significantly after 60 minutes (P = 0.007). The PaCO2 of the samples kept for 30 and 60 minutes at 22°C was significantly higher than primary result (P = 0.04, P samples stored at 22°C, pH decreased significantly after 30 and 60 minutes (P = 0.017, P = 0.001). There were no significant differences in other results of samples stored at 0°C or 22°C after 30 or 60 minutes. In samples stored in plastic syringes, overestimation of PaO2 levels should be noted if samples cooled before analysis. In samples stored in plastic syringes, it is not necessary to store samples in iced water when analysis delayed up to one hour.

  8. Effects of storage time and temperature on pH, specific gravity, and crystal formation in urine samples from dogs and cats.

    Science.gov (United States)

    Albasan, Hasan; Lulich, Jody P; Osborne, Carl A; Lekcharoensuk, Chalermpol; Ulrich, Lisa K; Carpenter, Kathleen A

    2003-01-15

    To determine effects of storage temperature and time on pH and specific gravity of and number and size of crystals in urine samples from dogs and cats. Randomized complete block design. 31 dogs and 8 cats. Aliquots of each urine sample were analyzed within 60 minutes of collection or after storage at room or refrigeration temperatures (20 vs 6 degrees C [68 vs 43 degrees F]) for 6 or 24 hours. Crystals formed in samples from 11 of 39 (28%) animals. Calcium oxalate (CaOx) crystals formed in vitro in samples from 1 cat and 8 dogs. Magnesium ammonium phosphate (MAP) crystals formed in vitro in samples from 2 dogs. Compared with aliquots stored at room temperature, refrigeration increased the number and size of crystals that formed in vitro; however, the increase in number and size of MAP crystals in stored urine samples was not significant. Increased storage time and decreased storage temperature were associated with a significant increase in number of CaOx crystals formed. Greater numbers of crystals formed in urine aliquots stored for 24 hours than in aliquots stored for 6 hours. Storage time and temperature did not have a significant effect on pH or specific gravity. Urine samples should be analyzed within 60 minutes of collection to minimize temperature- and time-dependent effects on in vitro crystal formation. Presence of crystals observed in stored samples should be validated by reevaluation of fresh urine.

  9. Impact of temperature and time storage on the microbial detection of oral samples by Checkerboard DNA-DNA hybridization method.

    Science.gov (United States)

    do Nascimento, Cássio; dos Santos, Janine Navarro; Pedrazzi, Vinícius; Pita, Murillo Sucena; Monesi, Nadia; Ribeiro, Ricardo Faria; de Albuquerque, Rubens Ferreira

    2014-01-01

    Molecular diagnosis methods have been largely used in epidemiological or clinical studies to detect and quantify microbial species that may colonize the oral cavity in healthy or disease. The preservation of genetic material from samples remains the major challenge to ensure the feasibility of these methodologies. Long-term storage may compromise the final result. The aim of this study was to evaluate the effect of temperature and time storage on the microbial detection of oral samples by Checkerboard DNA-DNA hybridization. Saliva and supragingival biofilm were taken from 10 healthy subjects, aliquoted (n=364) and processed according to proposed protocols: immediate processing and processed after 2 or 4 weeks, and 6 or 12 months of storage at 4°C, -20°C and -80°C. Either total or individual microbial counts were recorded in lower values for samples processed after 12 months of storage, irrespective of temperatures tested. Samples stored up to 6 months at cold temperatures showed similar counts to those immediately processed. The microbial incidence was also significantly reduced in samples stored during 12 months in all temperatures. Temperature and time of oral samples storage have relevant impact in the detection and quantification of bacterial and fungal species by Checkerboard DNA-DNA hybridization method. Samples should be processed immediately after collection or up to 6 months if conserved at cold temperatures to avoid false-negative results. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Storage Time and Urine Biomarker Levels in the ASSESS-AKI Study.

    Directory of Open Access Journals (Sweden)

    Kathleen D Liu

    Full Text Available Although stored urine samples are often used in biomarker studies focused on acute and chronic kidney disease, how storage time impacts biomarker levels is not well understood.866 subjects enrolled in the NIDDK-sponsored ASsessment, Serial Evaluation, and Subsequent Sequelae in Acute Kidney Injury (ASSESS-AKI Study were included. Samples were processed under standard conditions and stored at -70°C until analyzed. Kidney injury molecule-1 (KIM-1, neutrophil gelatinase-associated lipocalin (NGAL, interleukin-18 (IL-18, and liver fatty acid binding protein (L-FABP were measured in urine samples collected during the index hospitalization or an outpatient visit 3 months later. Mixed effects models were used to determine the effect of storage time on biomarker levels and stratified by visit.Median storage was 17.8 months (25-75% IQR 10.6-23.7 for samples from the index hospitalization and 14.6 months (IQR 7.3-20.4 for outpatient samples. In the mixed effects models, the only significant association between storage time and biomarker concentration was for KIM-1 in outpatient samples, where each month of storage was associated with a 1.7% decrease (95% CI -3% to -0.3%. There was no relationship between storage time and KIM-1 levels in samples from the index hospitalization.There was no significant impact of storage time over a median of 18 months on urine KIM-1, NGAL, IL-18 or L-FABP in hospitalized samples; a statistically significant effect towards a decrease over time was noted for KIM-1 in outpatient samples. Additional studies are needed to determine whether longer periods of storage at -70°C systematically impact levels of these analytes.

  11. Response of soil aggregate stability to storage time of soil samples

    International Nuclear Information System (INIS)

    Gerzabek, M.H.; Roessner, H.

    1993-04-01

    The aim of the present study was to investigate the well known phenomenon of changing aggregate stability values as result of soil sample storage. In order to evaluate the impact of soil microbial activity, the soil sample was split into three subsamples. Two samples were sterilized by means of chloroform fumigation and gamma irradiation, respectively. However, the aggregate stability measurements at three different dates were not correlated with the microbial activity (dehydrogenase activity). The moisture content of the aggregate samples seems to be of higher significance. Samples with lower moisture content (range: 0.4 to 1.9%) exhibited higher aggregate stabilities. Thus, airdried aggregate samples without further treatment don't seem to be suitable for standardized stability measurements. (authors)

  12. Storage Time and Urine Biomarker Levels in the ASSESS-AKI Study

    Science.gov (United States)

    Liu, Kathleen D.; Siew, Edward D.; Reeves, W. Brian; Himmelfarb, Jonathan; Go, Alan S.; Hsu, Chi-yuan; Bennett, Michael R.; Devarajan, Prasad; Ikizler, T. Alp; Kaufman, James S.; Kimmel, Paul L.; Chinchilli, Vernon M.; Parikh, Chirag R.

    2016-01-01

    Background Although stored urine samples are often used in biomarker studies focused on acute and chronic kidney disease, how storage time impacts biomarker levels is not well understood. Methods 866 subjects enrolled in the NIDDK-sponsored ASsessment, Serial Evaluation, and Subsequent Sequelae in Acute Kidney Injury (ASSESS-AKI) Study were included. Samples were processed under standard conditions and stored at -70°C until analyzed. Kidney injury molecule-1 (KIM-1), neutrophil gelatinase-associated lipocalin (NGAL), interleukin-18 (IL-18), and liver fatty acid binding protein (L-FABP) were measured in urine samples collected during the index hospitalization or an outpatient visit 3 months later. Mixed effects models were used to determine the effect of storage time on biomarker levels and stratified by visit. Results Median storage was 17.8 months (25–75% IQR 10.6–23.7) for samples from the index hospitalization and 14.6 months (IQR 7.3–20.4) for outpatient samples. In the mixed effects models, the only significant association between storage time and biomarker concentration was for KIM-1 in outpatient samples, where each month of storage was associated with a 1.7% decrease (95% CI -3% to -0.3%). There was no relationship between storage time and KIM-1 levels in samples from the index hospitalization. Conclusion There was no significant impact of storage time over a median of 18 months on urine KIM-1, NGAL, IL-18 or L-FABP in hospitalized samples; a statistically significant effect towards a decrease over time was noted for KIM-1 in outpatient samples. Additional studies are needed to determine whether longer periods of storage at -70°C systematically impact levels of these analytes. PMID:27788160

  13. Technical Note: Comparison of storage strategies of sea surface microlayer samples

    Directory of Open Access Journals (Sweden)

    K. Schneider-Zapp

    2013-07-01

    Full Text Available The sea surface microlayer (SML is an important biogeochemical system whose physico-chemical analysis often necessitates some degree of sample storage. However, many SML components degrade with time so the development of optimal storage protocols is paramount. We here briefly review some commonly used treatment and storage protocols. Using freshwater and saline SML samples from a river estuary, we investigated temporal changes in surfactant activity (SA and the absorbance and fluorescence of chromophoric dissolved organic matter (CDOM over four weeks, following selected sample treatment and storage protocols. Some variability in the effectiveness of individual protocols most likely reflects sample provenance. None of the various protocols examined performed any better than dark storage at 4 °C without pre-treatment. We therefore recommend storing samples refrigerated in the dark.

  14. Algae viability over time in a ballast water sample

    Science.gov (United States)

    Gollasch, Stephan; David, Matej

    2018-03-01

    The biology of vessels' ballast water needs to be analysed for several reasons, one of these being performance tests of ballast water management systems. This analysis includes a viability assessment of phytoplankton. To overcome logistical problems to get algae sample processing gear on board of a vessel to document algae viability, samples may be transported to land-based laboratories. Concerns were raised how the storage conditions of the sample may impact algae viability over time and what the most appropriate storage conditions were. Here we answer these questions with a long-term algae viability study with daily sample analysis using Pulse-Amplitude Modulated (PAM) fluorometry. The sample was analysed over 79 days. We tested different storage conditions: fridge and room temperature with and without light. It seems that during the first two weeks of the experiment the viability remains almost unchanged with a slight downwards trend. In the continuing period, before the sample was split, a slightly stronger downwards viability trend was observed, which occurred at a similar rate towards the end of the experiment. After the sample was split, the strongest viability reduction was measured for the sample stored without light at room temperature. We concluded that the storage conditions, especially regarding temperature and light exposure, have a stronger impact on algae viability compared to the storage duration and that inappropriate storage conditions reduce algal viability. A sample storage time of up to two weeks in a dark and cool environment has little influence on the organism viability. This indicates that a two week time duration between sample taking on board a vessel and the viability measurement in a land-based laboratory may not be very critical.

  15. Review of robust measurement of phosphorus in river water: sampling, storage, fractionation and sensitivity

    Directory of Open Access Journals (Sweden)

    H. P. Jarvie

    2002-01-01

    Full Text Available This paper reviews current knowledge on sampling, storage and analysis of phosphorus (P in river waters. Potential sensitivity of rivers with different physical, chemical and biological characteristics (trophic status, turbidity, flow regime, matrix chemistry is examined in terms of errors associated with sampling, sample preparation, storage, contamination, interference and analytical errors. Key issues identified include: The need to tailor analytical reagents and concentrations to take into account the characteristics of the sample matrix. The effects of matrix interference on the colorimetric analysis. The influence of variable rates of phospho-molybdenum blue colour formation. The differing responses of river waters to physical and chemical conditions of storage. The higher sensitivities of samples with low P concentrations to storage and analytical errors. Given high variability of river water characteristics in space and time, no single standardised methodology for sampling, storage and analysis of P in rivers can be offered. ‘Good Practice’ guidelines are suggested, which recommend that protocols for sampling, storage and analysis of river water for P is based on thorough site-specific method testing and assessment of P stability on storage. For wider sampling programmes at the regional/national scale where intensive site-specific method and stability testing are not feasible, ‘Precautionary Practice’ guidelines are suggested. The study highlights key areas requiring further investigation for improving methodological rigour. Keywords: phosphorus, orthophosphate, soluble reactive, particulate, colorimetry, stability, sensitivity, analytical error, storage, sampling, filtration, preservative, fractionation, digestion

  16. Practical reporting times for environmental samples

    International Nuclear Information System (INIS)

    Bayne, C.K.; Schmoyer, D.D.; Jenkins, R.A.

    1993-02-01

    Preanalytical holding times for environmental samples are specified because chemical and physical characteristics may change between sampling and chemical analysis. For example, the Federal Register prescribes a preanalytical holding time of 14 days for volatile organic compounds in soil stored at 4 degrees C. The American Society for Testing Materials (ASTM) uses a more technical definition that the preanalytical holding time is the day when the analyte concentration for an environmental sample falls below the lower 99% confidence interval on the analyte concentration at day zero. This study reviews various holding time definitions and suggest a new preanalytical holding time approach using acceptable error rates for measuring an environmental analyte. This practical reporting time (PRT) approach has been applied to nineteen volatile organic compounds and four explosives in three environmental soil samples. A PRT nomograph of error rates has been developed to estimate the consequences of missing a preanalytical holding time. This nomograph can be applied to a large class of analytes with concentrations that decay linearly or exponentially with time regardless of sample matrices and storage conditions

  17. Practical reporting times for environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Bayne, C.K.; Schmoyer, D.D.; Jenkins, R.A.

    1993-02-01

    Preanalytical holding times for environmental samples are specified because chemical and physical characteristics may change between sampling and chemical analysis. For example, the Federal Register prescribes a preanalytical holding time of 14 days for volatile organic compounds in soil stored at 4{degrees}C. The American Society for Testing Materials (ASTM) uses a more technical definition that the preanalytical holding time is the day when the analyte concentration for an environmental sample falls below the lower 99% confidence interval on the analyte concentration at day zero. This study reviews various holding time definitions and suggest a new preanalytical holding time approach using acceptable error rates for measuring an environmental analyte. This practical reporting time (PRT) approach has been applied to nineteen volatile organic compounds and four explosives in three environmental soil samples. A PRT nomograph of error rates has been developed to estimate the consequences of missing a preanalytical holding time. This nomograph can be applied to a large class of analytes with concentrations that decay linearly or exponentially with time regardless of sample matrices and storage conditions.

  18. Congener Production in Blood Samples During Preparation and Storage

    DEFF Research Database (Denmark)

    Felby, Søren; Nielsen, Erik

    1995-01-01

    Retsmedicin, congener production, preparation, head space GC, acetone, isobutanol, storage, blood samples, n-propanol, methanol, methylethylketone......Retsmedicin, congener production, preparation, head space GC, acetone, isobutanol, storage, blood samples, n-propanol, methanol, methylethylketone...

  19. Sample preparation and storage can change arsenic speciation in human urine.

    Science.gov (United States)

    Feldmann, J; Lai, V W; Cullen, W R; Ma, M; Lu, X; Le, X C

    1999-11-01

    Stability of chemical speciation during sample handling and storage is a prerequisite to obtaining reliable results of trace element speciation analysis. There is no comprehensive information on the stability of common arsenic species, such as inorganic arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid, dimethylarsinic acid, and arsenobetaine, in human urine. We compared the effects of the following storage conditions on the stability of these arsenic species: temperature (25, 4, and -20 degrees C), storage time (1, 2, 4, and 8 months), and the use of additives (HCl, sodium azide, benzoic acid, benzyltrimethylammonium chloride, and cetylpyridinium chloride). HPLC with both inductively coupled plasma mass spectrometry and hydride generation atomic fluorescence detection techniques were used for the speciation of arsenic. We found that all five of the arsenic species were stable for up to 2 months when urine samples were stored at 4 and -20 degrees C without any additives. For longer period of storage (4 and 8 months), the stability of arsenic species was dependent on urine matrices. Whereas the arsenic speciation in some urine samples was stable for the entire 8 months at both 4 and -20 degrees C, other urine samples stored under identical conditions showed substantial changes in the concentration of As(III), As(V), monomethylarsonic acid, and dimethylarsinic acid. The use of additives did not improve the stability of arsenic speciation in urine. The addition of 0.1 mol/L HCl (final concentration) to urine samples produced relative changes in inorganic As(III) and As(V) concentrations. Low temperature (4 and -20 degrees C) conditions are suitable for the storage of urine samples for up to 2 months. Untreated samples maintain their concentration of arsenic species, and additives have no particular benefit. Strong acidification is not appropriate for speciation analysis.

  20. Storage Effects on Sample Integrity of Environmental Surface Sampling Specimens with Bacillus anthracis Spores.

    Science.gov (United States)

    Perry, K Allison; O'Connell, Heather A; Rose, Laura J; Noble-Wang, Judith A; Arduino, Matthew J

    The effect of packaging, shipping temperatures and storage times on recovery of Bacillus anthracis . Sterne spores from swabs was investigated. Macrofoam swabs were pre-moistened, inoculated with Bacillus anthracis spores, and packaged in primary containment or secondary containment before storage at -15°C, 5°C, 21°C, or 35°C for 0-7 days. Swabs were processed according to validated Centers for Disease Control/Laboratory Response Network culture protocols, and the percent recovery relative to a reference sample (T 0 ) was determined for each variable. No differences were observed in recovery between swabs held at -15° and 5°C, (p ≥ 0.23). These two temperatures provided significantly better recovery than swabs held at 21°C or 35°C (all 7 days pooled, p ≤ 0.04). The percent recovery at 5°C was not significantly different if processed on days 1, 2 or 4, but was significantly lower on day 7 (day 2 vs. 7, 5°C, 10 2 , p=0.03). Secondary containment provided significantly better percent recovery than primary containment, regardless of storage time (5°C data, p ≤ 0.008). The integrity of environmental swab samples containing Bacillus anthracis spores shipped in secondary containment was maintained when stored at -15°C or 5°C and processed within 4 days to yield the optimum percent recovery of spores.

  1. Comparison of Microbial Communities in Swine Manure at Various Temperatures and storage times.

    Science.gov (United States)

    Lim, Joung-Soo; Yang, Seung Hak; Kim, Bong-Soo; Lee, Eun Young

    2018-01-26

    This study was designed to investigate the effects of temperature and storage time on the evolution of bacterial communities in swine manure. Manure was stored at -20°C, 4°C, 20°C, or 37°C and sampled at 7-day intervals over 28 days of storage, for a total of 5 time points. To assess the bacterial species present, 16S ribosomal RNA gene sequences were analyzed using pyrosequencing. After normalization, 113,934 sequence reads were obtained, with an average length of 466.6 ± 4.4 bp. The diversity indices of the communities reduced as temperature and storage time increased, and the slopes of rarefaction curves decreased from the second week in samples stored at -20 °C and 4 °C. These results indicate that the richness of the bacterial community in the manure reduced as temperature and storage time increased. Firmicutes were the dominant phylum in all samples examined, ranging from 89.3% to 98.8% of total reads, followed by Actinobacteria, which accounted for 0.6% to 7.9%. A change in community composition was observed in samples stored at 37 °C during the first 7 days, indicating that temperature plays an important role in determining the microbiota of swine manure. Clostridium, Turicibacter, Streptococcus, and Lactobacillus within Firmicutes, and Corynebacterium within Actinobacteria were the most dominant genera in fresh manure and all stored samples. Based on our findings, we propose Clostridium as an indicator genus of swine manure decomposition in an anaerobic environment. The proportions of dominant genera changed in samples stored at 20 °C and 37 °C during the fourth week. Based on these results, it was concluded that the microbial communities of swine manure change rapidly as storage time and temperature increase.

  2. Sampling and decontamination plan for the Transuranic Storage Area--1/-R container storage unit

    International Nuclear Information System (INIS)

    Barry, G.A.

    1992-11-01

    This document describes the sampling and decontamination of the Transuranic Storage Area (TSA)-l/-R container storage area and the earthen-covered portion of the TSA-2 container storage unit at the Radioactive Waste Management Complex. Stored containers from the earthen-covered asphalt pads will be retrieved from the TSA-l/-R and TSA-2 container storage units. Container retrieval will be conducted under the TSA retrieval enclosure, a fabricated steel building to be constructed over the earthen-covered pad to provide containment and weather protection. Following container retrieval, the TSA retrieval enclosure will be decontaminated to remove radioactive and hazardous contamination. The underlying soils will be sampled and analyzed to determine whether any contaminated soils require removal

  3. Fuji apple storage time rapid determination method using Vis/NIR spectroscopy

    Science.gov (United States)

    Liu, Fuqi; Tang, Xuxiang

    2015-01-01

    Fuji apple storage time rapid determination method using visible/near-infrared (Vis/NIR) spectroscopy was studied in this paper. Vis/NIR diffuse reflection spectroscopy responses to samples were measured for 6 days. Spectroscopy data were processed by stochastic resonance (SR). Principal component analysis (PCA) was utilized to analyze original spectroscopy data and SNR eigen value. Results demonstrated that PCA could not totally discriminate Fuji apples using original spectroscopy data. Signal-to-noise ratio (SNR) spectrum clearly classified all apple samples. PCA using SNR spectrum successfully discriminated apple samples. Therefore, Vis/NIR spectroscopy was effective for Fuji apple storage time rapid discrimination. The proposed method is also promising in condition safety control and management for food and environmental laboratories. PMID:25874818

  4. A confirmatory holding time study for purgeable VOCs in water samples

    International Nuclear Information System (INIS)

    West, O.R.; Bayne, C.K.; Siegrist, R.L.; Holden, W.H.; Bottrell, D.W.

    1996-01-01

    Analyte stability during pre-analytical storage is essential to the accurate quantification contaminants in environmental samples. This is particularly true for volatile organic compounds (VOCS) which can easily volatilize and/or degrade during sample storage. Recognizing this, regulatory agencies require water samples be collected in vials without headspace and stored at 4 degrees C, and that analyses be conducted within 14 days, 2048 even if samples are acid-preserved. Since the selection of a 14-day holding time was largely arbitrary, the appropriateness of this requirement must be re-evaluated. The goal of the study described here was to provide regulatory agencies with the necessary data to extend the maximum holding time for properly preserved VOC water samples to 28 days

  5. A novel storage system for cryoEM samples.

    Science.gov (United States)

    Scapin, Giovanna; Prosise, Winifred W; Wismer, Michael K; Strickland, Corey

    2017-07-01

    We present here a new CryoEM grid boxes storage system designed to simplify sample labeling, tracking and retrieval. The system is based on the crystal pucks widely used by the X-ray crystallographic community for storage and shipping of crystals. This system is suitable for any cryoEM laboratory, but especially for large facilities that will need accurate tracking of large numbers of samples coming from different sources. Copyright © 2017. Published by Elsevier Inc.

  6. Evaluation of continued storage of samples at the 325 Laboratory

    International Nuclear Information System (INIS)

    McVey, C.B.

    1996-01-01

    This report provides identification of potential Program users for samples that are archived at Pacific Northwest National Laboratory (PNNL) facilities, establishes cost releated to packaging and transportation of these samples to 222-S, for continued storage at 325 facilities, disposal and transfer costs. The report provides a recommendation to dispose of 20 samples, transfer 99 samples to PNNL and to continue storage of the remaining samples at PNNL's 325 facility

  7. Correlation of the levels of glycosaminoglycans between urine and dried urine in filter paper samples and their stability over time under different storage temperatures.

    Science.gov (United States)

    Breier, Ana Carolina; Cé, Jaqueline; Coelho, Janice Carneiro

    2014-06-10

    Mucopolysaccharidoses (MPSs) are a group of lysosomal storage diseases caused by the deficiency/absence of enzymes which catalyze the degradation of glycosaminoglycans (GAGs). The use of biological samples dried on filter paper has been increasing because it makes it easy to ship them to reference laboratories. Urinary GAGs are the main biomarkers of MPS and, thus, we studied the correlations of determinations to GAGs and creatinine, as well as compared the GAGs' profile on electrophoresis, between urine and dried urine in filter paper (DUFP) samples. We also assessed the GAG stability over time under different storage temperatures. We quantified the GAG concentration in both sample types and compared the results by Pearson correlation. The results were very similar, with r=0.97 for creatinine and with r=0.94 and r=0.98 for GAGs for controls and patients, respectively, with similar electrophoretic profiles. The GAG stability in DUFP was up to 30days at -20, 4, and 25°C and up to 21days at 37°C. Our proposal assessed urinary GAGs in DUFP and concluded that these samples can be used in the investigation of MPS, replacing urine samples in neonatal screening and monitoring of therapies, due to ease of transportation and storage. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. PCR detection of malaria parasites in desiccated Anopheles mosquitoes is uninhibited by storage time and temperature

    Directory of Open Access Journals (Sweden)

    Rider Mark A

    2012-06-01

    Full Text Available Abstract Background Reliable methods to preserve mosquito vectors for malaria studies are necessary for detecting Plasmodium parasites. In field settings, however, maintaining a cold chain of storage from the time of collection until laboratory processing, or accessing other reliable means of sample preservation is often logistically impractical or cost prohibitive. As the Plasmodium infection rate of Anopheles mosquitoes is a central component of the entomological inoculation rate and other indicators of transmission intensity, storage conditions that affect pathogen detection may bias malaria surveillance indicators. This study investigated the effect of storage time and temperature on the ability to detect Plasmodium parasites in desiccated Anopheles mosquitoes by real-time polymerase chain reaction (PCR. Methods Laboratory-infected Anopheles stephensi mosquitoes were chloroform-killed and stored over desiccant for 0, 1, 3, and 6 months while being held at four different temperatures: 28, 37, -20 and -80°C. The detection of Plasmodium DNA was evaluated by real-time PCR amplification of a 111 base pair region of block 4 of the merozoite surface protein. Results Varying the storage time and temperature of desiccated mosquitoes did not impact the sensitivity of parasite detection. A two-way factorial analysis of variance suggested that storage time and temperature were not associated with a loss in the ability to detect parasites. Storage of samples at 28°C resulted in a significant increase in the ability to detect parasite DNA, though no other positive associations were observed between the experimental storage treatments and PCR amplification. Conclusions Cold chain maintenance of desiccated mosquito samples is not necessary for real-time PCR detection of parasite DNA. Though field-collected mosquitoes may be subjected to variable conditions prior to molecular processing, the storage of samples over an inexpensive and logistically

  9. Quality Assessment of Platelet-Rich Fibrin-Like Matrix Prepared from Whole Blood Samples after Extended Storage

    Directory of Open Access Journals (Sweden)

    Hideo Kawabata

    2017-09-01

    Full Text Available The platelet-rich fibrin–like matrix (PRFM is usually prepared onsite and immediately used for regenerative therapy. Nonetheless, to meet the clinical necessity of preserving the PRFM without quality deterioration, we developed a method for preparation of PRFMs from short-term-stored whole blood (WB samples. In this study, to evaluate the practical expiration date of storage, we extended the storage time of WB samples from 2 to 7 days and assessed the quality of the resulting PRFMs. WB samples collected with acid-citrate-dextrose were stored with gentle agitation at ambient temperature. To prepare PRFMs, the stored WB samples were mixed with CaCl2 in glass tubes and centrifuged. Fibrin fiber networks, CD41 and CD62P expression, and Platelet Derived Growth Factor-BB (PDGF-BB levels were examined by scanning electron microscopy (SEM, flow cytometry, and an Enzyme-Linked ImmunoSorbent Assay (ELISA, respectively. Long-term storage had no significant effect on either blood cell counts or platelet functions tested. The resulting PRFMs were visually identical to freshly prepared ones. PDGF-BB levels did not markedly decrease in a time-dependent manner. However, fibrin fibers gradually became thinner after storage. Although the coagulation activity may diminish, we propose that PRFMs can be prepared—without evident loss of quality—from WB samples stored for up to 7 days by our previously developed method.

  10. The UK Biobank sample handling and storage validation studies.

    Science.gov (United States)

    Peakman, Tim C; Elliott, Paul

    2008-04-01

    and aims UK Biobank is a large prospective study in the United Kingdom to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. It involves the collection of blood and urine from 500 000 individuals aged between 40 and 69 years. How the samples are collected, processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. A series of validation studies was recommended to test the robustness of the draft sample handling and storage protocol. Samples of blood and urine were collected from 40 healthy volunteers and either processed immediately according to the protocol or maintained at specified temperatures (4 degrees C for all tubes with the exception of vacutainers containing acid citrate dextrose that were maintained at 18 degrees C) for 12, 24 or 36 h prior to processing. A further sample was maintained for 24 h at 4 degrees C, processed and the aliquots frozen at -80 degrees C for 20 days and then thawed under controlled conditions. The stability of the samples was compared for the different times in a wide variety of assays. The samples maintained at 4 degrees C were stable for at least 24 h after collection for a wide range of assays. Small but significant changes were observed in metabonomic studies in samples maintained at 4 degrees C for 36 h. There was no degradation of the samples for a range of biochemical assays after short-term freezing and thawing under controlled conditions. Whole blood maintained at 18 degrees C for 24 h in vacutainers containing acid citrate dextrose is suitable for viral immortalization techniques. The validation studies reported in this supplement provide justification for the sample handling and storage procedures adopted in the UK Biobank project.

  11. The effect of substrate composition and storage time on urine specific gravity in dogs.

    Science.gov (United States)

    Steinberg, E; Drobatz, K; Aronson, L

    2009-10-01

    The purpose of this study is to evaluate the effects of substrate composition and storage time on urine specific gravity in dogs. A descriptive cohort study of 15 dogs. The urine specific gravity of free catch urine samples was analysed during a 5-hour time period using three separate storage methods; a closed syringe, a diaper pad and non-absorbable cat litter. The urine specific gravity increased over time in all three substrates. The syringe sample had the least change from baseline and the diaper sample had the greatest change from baseline. The urine specific gravity for the litter and diaper samples had a statistically significant increase from the 1-hour to the 5-hour time point. The urine specific gravity from canine urine stored either on a diaper or in a non-absorbable litter increased over time. Although the change was found to be statistically significant over the 5-hour study period it is unlikely to be clinically significant.

  12. Long-time data storage: relevant time scales

    NARCIS (Netherlands)

    Elwenspoek, Michael Curt

    2011-01-01

    Dynamic processes relevant for long-time storage of information about human kind are discussed, ranging from biological and geological processes to the lifecycle of stars and the expansion of the universe. Major results are that life will end ultimately and the remaining time that the earth is

  13. Microbial Condition of Water Samples from Foreign Fuel Storage Facilities

    International Nuclear Information System (INIS)

    Berry, C.J.

    1998-01-01

    In order to assess the microbial condition of foreign spent nuclear fuel storage facilities and their possible impact on SRS storage basins, twenty-three water samples were analyzed from 12 different countries. Fifteen of the water samples were analyzed and described in an earlier report (WSRC-TR-97-00365 [1]). This report describes nine additional samples received from October 1997 through March 1998. The samples include three from Australia, two from Denmark and Germany and one sample from Italy and Greece. Each water sample was analyzed for microbial content and activity as determined by total bacteria, viable aerobic bacteria, viable anaerobic bacteria, viable sulfate-reducing bacteria, viable acid-producing bacteria and enzyme diversity. The results for each water sample were then compared to all other foreign samples analyzed to date and monthly samples pulled from the receiving basin for off-site fuel (RBOF), at SRS. Of the nine samples analyzed, four samples from Italy, Germany and Greece had considerably higher microbiological activity than that historically found in the RBOF. This microbial activity included high levels of enzyme diversity and the presence of viable organisms that have been associated with microbial influenced corrosion in other environments. The three samples from Australia had microbial activities similar to that in the RBOF while the two samples from Denmark had lower levels of microbial activity. These results suggest that a significant number of the foreign storage facilities have water quality standards that allow microbial proliferation and survival

  14. Shielding design of highly activated sample storage at reactor TRIGA PUSPATI

    International Nuclear Information System (INIS)

    Naim Syauqi Hamzah; Julia Abdul Karim; Mohamad Hairie Rabir; Muhd Husamuddin Abdul Khalil; Mohd Amin Sharifuldin Salleh

    2010-01-01

    Radiation protection has always been one of the most important things considered in Reaktor Triga PUSPATI (RTP) management. Currently, demands on sample activation were increased from variety of applicant in different research field area. Radiological hazard may occur if the samples evaluation done were misjudge or miscalculated. At present, there is no appropriate storage for highly activated samples. For that purpose, special irradiated samples storage box should be provided in order to segregate highly activated samples that produce high dose level and typical activated samples that produce lower dose level (1 - 2 mR/ hr). In this study, thickness required by common shielding material such as lead and concrete to reduce highly activated radiotracer sample (potassium bromide) with initial exposure dose of 5 R/ hr to background level (0.05 mR/ hr) were determined. Analyses were done using several methods including conventional shielding equation, half value layer calculation and Micro shield computer code. Design of new irradiated samples storage box for RTP that capable to contain high level gamma radioactivity were then proposed. (author)

  15. Influence of different storage times and temperatures on blood gas ...

    African Journals Online (AJOL)

    The present study was designed to investigate the effects of storage temperature and time on blood gas and acid-base balance of ovine venous blood. Ten clinically healthy sheep were used in this study. A total number of 30 blood samples, were divided into three different groups, and were stored in a refrigerator adjusted ...

  16. Variation in content of macronutrients of guava tree leaves, in function of type and time of storage

    Directory of Open Access Journals (Sweden)

    Henrique Antunes de Souza

    2010-10-01

    Full Text Available Leaf analysis for perennial crops such as the guava tree is an important tool. It was used to evaluate the influence of the type of packaging (with or without refrigerator and storage time after collection on the macronutrient composition of guava tree leaves. The leaf sampling was carried out on a commercial guava tree (cv. Paluma, collecting the third pair of recently matured leaves in full bloom. The experimental design was in randomized blocks, subdivided according to the type of packaging (with or without refrigerator and further subdivided into eight storage times before washing (zero, 6, 12, 24, 48, 72, 96 and 168h after sampling, with four replications. The storage time significantly affected the concentration of leaf nitrogen, calcium and sulfur. Moreover, the type and time of conditioning (with or without refrigerator affected only the magnesium. In general, storage fot up to 12h before washing produced no significant changes in the levels of macronutrients.

  17. Variation in content of macronutrients of guava tree leaves, in function of type and time of storage

    Directory of Open Access Journals (Sweden)

    Henrique Antunes de Souza

    2010-09-01

    Full Text Available Leaf analysis for perennial crops such as the guava tree is an important tool. It was used to evaluate the influence of the type of packaging (with or without refrigerator and storage time after collection on the macronutrient composition of guava tree leaves. The leaf sampling was carried out on a commercial guava tree (cv. Paluma, collecting the third pair of recently matured leaves in full bloom. The experimental design was in randomized blocks, subdivided according to the type of packaging (with or without refrigerator and further subdivided into eight storage times before washing (zero, 6, 12, 24, 48, 72, 96 and 168h after sampling, with four replications. The storage time significantly affected the concentration of leaf nitrogen, calcium and sulfur. Moreover, the type and time of conditioning (with or without refrigerator affected only the magnesium. In general, storage fot up to 12h before washing produced no significant changes in the levels of macronutrients.

  18. Effects of Transport and Storage Conditions on Gene Expression in Blood Samples.

    Science.gov (United States)

    Malentacchi, Francesca; Pizzamiglio, Sara; Wyrich, Ralf; Verderio, Paolo; Ciniselli, Chiara; Pazzagli, Mario; Gelmini, Stefania

    2016-04-01

    Inappropriate handling of blood samples might induce or repress gene expression and/or lead to RNA degradation affecting downstream analysis. In particular, sample transport is a critical step for biobanking or multicenter studies because of uncontrolled variables (i.e., unstable temperature). We report the results of a pilot study implemented within the EC funded SPIDIA project, aimed to investigate the role of transport and storage of blood samples containing and not containing an RNA stabilizer. Blood was collected from a single donor both in EDTA and in PAXgene Blood RNA tubes. Half of the samples were sent to a second laboratory both at room temperature and at 4°C, whereas the remaining samples were stored at room temperature and at 4°C. Gene expression of selected genes (c-FOS, IL-1β, IL-8, and GAPDH) known to be induced or repressed by ex vivo blood handling and of blood-mRNA quality biomarkers identified and validated within the SPIDIA project, which allow for monitoring changes in unstabilized blood samples after collection and during transport and storage, were analyzed by RT-qPCR. If the shipment of blood in tubes not containing RNA stabilizer is not performed under a stable condition, gene profile studies can be affected by the effects of transport. Moreover, also controlled temperature shipment (4°C) can influence the expression of specific genes if blood is collected in tubes not containing a stabilizer. The use of dedicated biomarkers or time course experiments should be performed in order to verify potential bias on gene expression analysis due to sample shipment and storage conditions. Alternatively, the use of RNA stabilizer containing tubes can represent a reliable option to avoid ex vivo RNA changes.

  19. Target Tracking of a Linear Time Invariant System under Irregular Sampling

    Directory of Open Access Journals (Sweden)

    Jin Xue-Bo

    2012-11-01

    Full Text Available Due to event-triggered sampling in a system, or maybe with the aim of reducing data storage, tracking many applications will encounter irregular sampling time. By calculating the matrix exponential using an inverse Laplace transform, this paper transforms the irregular sampling tracking problem to the problem of tracking with time-varying parameters of a system. Using the common Kalman filter, the developed method is used to track a target for the simulated trajectory and video tracking. The results of simulation experiments have shown that it can obtain good estimation performance even at a very high irregular rate of measurement sampling time.

  20. Time-dependent integrity during storage of natural surface water samples for the trace analysis of pharmaceutical products, feminizing hormones and pesticides

    Directory of Open Access Journals (Sweden)

    Prévost Michèle

    2010-04-01

    Full Text Available Abstract Monitoring and analysis of trace contaminants such as pharmaceuticals and pesticides require the preservation of the samples before they can be quantified using the appropriate analytical methods. Our objective is to determine the sample shelf life to insure proper quantification of ultratrace contaminants. To this end, we tested the stability of a variety of pharmaceutical products including caffeine, natural steroids, and selected pesticides under refrigerated storage conditions. The analysis was performed using multi-residue methods using an on-line solid-phase extraction combined with liquid chromatography tandem mass spectrometry (SPE-LC-MS/MS in the selected reaction monitoring mode. After 21 days of storage, no significant difference in the recoveries was observed compared to day 0 for pharmaceutical products, while for pesticides, significant losses occurred for DIA and simazine after 10 days (14% and 17% reduction respectively and a statistically significant decrease in the recovery was noted for cyanazine (78% disappearance. However, the estrogen and progestogen steroids were unstable during storage. The disappearance rates obtained after 21 days of storage vary from 63 to 72% for the feminizing hormones. Overall, pharmaceuticals and pesticides seem to be stable for refrigerated storage for up to about 10 days (except cyanazine and steroidal hormones can be quite sensitive to degradation and should not be stored for more than a few days.

  1. The effects of storage temperature and duration of blood samples on DNA and RNA qualities.

    Science.gov (United States)

    Huang, Lien-Hung; Lin, Pei-Hsien; Tsai, Kuo-Wang; Wang, Liang-Jen; Huang, Ying-Hsien; Kuo, Ho-Chang; Li, Sung-Chou

    2017-01-01

    DNA and RNA samples from blood are the common examination target for non-invasive physical tests and/or biomedical studies. Since high-quality DNA and RNA samples guarantee the correctness of these tests and/or studies, we investigated the effects of storage temperature and storage duration of whole blood on DNA and RNA qualities. Subjects were enrolled to donate blood samples which were stored for different durations and at different temperatures, followed by the examinations on RNA quality, qPCR, DNA quality and DNA methylation. For RNA, we observed obvious quality decline with storage duration longer than 24 hours. Storage at low temperature does not keep RNA samples from degradation. And, storing whole blood samples in freezer dramatically damage RNA. For DNA, quality decline was not observed even with storage duration for 15 days. However, DNA methylation significantly altered with storage duration longer than three days. Storage duration within 24 hours is critical for collecting high-quality RNA samples for next-generation sequencing (NGS) assays (RIN≧8). If microarray assays are expected (RIN≧7), storage duration within 32 hours is acceptable. Although DNA is resistant within 15 days when kept in whole blood, DNA quantity dramatically decreases owing to WBC lysis. In addition, duration for more than three days significantly alter DNA methylation status, globally and locally. Our result provides a reference for dealing with blood samples.

  2. Impact of sample processing on the measurement of circulating microparticles: storage and centrifugation parameters.

    Science.gov (United States)

    Vila-Liante, Virtudes; Sánchez-López, Verónica; Martínez-Sales, Vicenta; Ramón-Nuñez, Luis A; Arellano-Orden, Elena; Cano-Ruiz, Alejandra; Rodríguez-Martorell, Francisco J; Gao, Lin; Otero-Candelera, Remedios

    2016-11-01

    Microparticles (MPs) have been shown to be markers of cellular activation and interactions. Pre-analytical conditions such as the centrifugation protocol and sample storage conditions represent an important source of variability in determining MPs values. The objectives of this study were to evaluate the influence of sample storage conditions and centrifugation speed and temperature on the determination of MPs in plasma. Citrate-anticoagulated blood samples obtained from 21 healthy subjects were centrifuged under four different protocols involving different speeds (2500 g or 1500 g) and temperatures (4 °C or 20 °C) to isolate platelet-poor plasma (PPP). The number of MPs in fresh and frozen-thawed PPP were analyzed by flow cytometry, and MPs-mediated procoagulant activity was determined by a thrombin generation test and phospholipid-dependent procoagulant tests. The number of MPs and their procoagulant activity were affected by freeze-thaw cycling and centrifugation speed but not by centrifugation temperature. Sample freezing increased MPs number (six-fold) and thrombin generation (four-fold), and decreased clotting time (two-fold). Low centrifugation speed caused an increase in MPs number and a parallel increase in MP-mediated procoagulant activity. Sample storage conditions and centrifugation speed are important processing conditions affecting MPs number and activity. Before any study, the protocol for MPs isolation should be optimized to ensure a reliable characterization of MPs, which could provide important information for diagnostic purposes and for understanding the pathogenesis of diseases.

  3. Studies on bacterial community composition are affected by the time and storage method of the rumen content.

    Science.gov (United States)

    Granja-Salcedo, Yury Tatiana; Ramirez-Uscategui, Ricardo Andrés; Machado, Elwi Guillermo; Duarte Messana, Juliana; Takeshi Kishi, Luciano; Lino Dias, Ana Veronica; Berchielli, Telma Teresinha

    2017-01-01

    The objective of this study was to investigate three storage methods and four storage times for rumen sampling in terms of quality and yield of extracted metagenomic DNA as well as the composition of the rumen bacterial community. One Nellore steer fitted with a ruminal silicone-type cannula was used as a donor of ruminal contents. The experiment comprised 11 experimental groups: pellet control (PC), lyophilized control (LC), P-20: pellet stored frozen at -20°C for a period of 3, 6, and 12 months, P-80: pellet stored frozen at -80°C for a period of 3, 6, and 12 months, and L-20: lyophilized sample stored frozen at -20°C for a period of 3, 6, and 12 months. Metagenomic DNA concentrations were measured spectrophotometrically and fluorometrically and ion torrent sequencing was used to assess the bacterial community composition. The L-20 method could not maintain the yield of DNA during storage. In addition, the P-80 group showed a greater yield of metagenomic DNA than the other groups after 6 months of storage. Rumen samples stored as pellets (P-20 and P-80) resulted in lower richness Chao 1, ACE, and Shannon Wiener indices when compared to PC, while LC and PC were only different in richness ACE. The storage method and storage time influenced the proportions of 14 of 17 phyla identified by sequencing. In the P-20 group, the proportion of Cyanobacteria, Elusimicrobia, Fibrobacteres, Lentisphaerae, Proteobacteria, and Spirochaetes phyla identified was lower than 1%. In the P-80 group, there was an increase in the proportion of the Bacteroidetes phylum (p = 0.010); however, the proportion of Actinobacteria, Chloroflexi, SR1, Synergistetes, TM7, and WPS.2 phyla were unchanged compared to the PC group (p > 0.05). The class Clostridium was the most abundant in all stored groups and increased in its proportion, especially in the L-20 group. The rumen sample storage time significantly reduced the yield of metagenomic DNA extracted. Therefore, the storage method can

  4. Control of photon storage time using phase locking.

    Science.gov (United States)

    Ham, Byoung S

    2010-01-18

    A photon echo storage-time extension protocol is presented by using a phase locking method in a three-level backward propagation scheme, where phase locking serves as a conditional stopper of the rephasing process in conventional two-pulse photon echoes. The backward propagation scheme solves the critical problems of extremely low retrieval efficiency and pi rephasing pulse-caused spontaneous emission noise in photon echo based quantum memories. The physics of the storage time extension lies in the imminent population transfer from the excited state to an auxiliary spin state by a phase locking control pulse. We numerically demonstrate that the storage time is lengthened by spin dephasing time.

  5. Multiple sample setup for testing the hydrothermal stability of adsorbents in thermal energy storage applications

    International Nuclear Information System (INIS)

    Fischer, Fabian; Laevemann, Eberhard

    2015-01-01

    Thermal energy storage based on adsorption and desorption of water on an adsorbent can achieve high energy storage densities. Many adsorbents lose adsorption capacity when operated under unfavourable hydrothermal conditions during adsorption and desorption. The stability of an adsorbent against stressing hydrothermal conditions is a key issue for its usability in adsorption thermal energy storage. We built an experimental setup that simultaneously controls the hydrothermal conditions of 16 samples arranged in a matrix of four temperatures and four water vapour pressures. This setup allows the testing of potential adsorbents between temperatures of 50 °C and 350 °C and water vapour pressures of up to 32 kPa. A measurement procedure that allows the detection of the hydrothermal stability of an adsorbent after defined time spans has been designed. We verified the functionality of the multiple sample measurements with a microporous adsorbent, a zeolite NaMSX. The hydrothermal stability of this zeolite is tested by water uptake measurements. A standard deviation lower than 1% of the 16 samples for detecting the hydrothermal stability enables setting different conditions in each sample cell. Further, we compared the water uptake measurements by measuring their adsorption isotherms with the volumetric device BELSORP Aqua 3 from Bel Japan. (paper)

  6. Views of female breast cancer patients who donated biologic samples regarding storage and use of samples for genetic research.

    Science.gov (United States)

    Kaphingst, K A; Janoff, J M; Harris, L N; Emmons, K M

    2006-05-01

    Although social and ethical issues related to the storage and use of biologic specimens for genetic research have been discussed extensively in the medical literature, few empiric data exist describing patients' views. This qualitative study explored the views of 26 female breast cancer patients who had consented to donate blood or tissue samples for breast cancer research. Participants generally did not expect personal benefits from research and had few unprompted concerns. Few participants had concerns about use of samples for studies not planned at the time of consent. Some participants did express concerns about insurance or employment discrimination, while others believed that current privacy protections might actually slow breast cancer research. Participants were generally more interested in receiving individual genetic test results from research studies than aggregate results. Most participants did not want individual results of uncertain clinical significance, although others believed that they should be able to receive such information. These data examined the range of participants' views regarding the storage and use of biologic samples. Further research with different and diverse patient populations is critical to establishing an appropriate balance between protecting the rights of human subjects in genetic research and allowing research to progress.

  7. Spatial distribution of residence time, microbe and storage volume of groundwater in headwater catchments

    Science.gov (United States)

    Tsujimura, Maki; Ogawa, Mahiro; Yamamoto, Chisato; Sakakibara, Koichi; Sugiyama, Ayumi; Kato, Kenji; Nagaosa, Kazuyo; Yano, Shinjiro

    2017-04-01

    Headwater catchments in mountainous region are the most important recharge area for surface and subsurface waters, and time and stock information of the water is principal to understand hydrological processes in the catchments. Also, a variety of microbes are included in the groundwater and spring water, and those varies in time and space, suggesting that information of microbe could be used as tracer for groundwater flow system. However, there have been few researches to evaluate the relationship among the residence time, microbe and storage volume of the groundwater in headwater catchments. We performed an investigation on age dating using SF6 and CFCs, microbe counting in the spring water, and evaluation of groundwater storage volume based on water budget analysis in 8 regions underlain by different lithology, those are granite, dacite, sedimentary rocks, serpentinite, basalt and volcanic lava all over Japan. We conducted hydrometric measurements and sampling of spring water in base flow conditions during the rainless periods 2015 and 2016 in those regions, and SF6, CFCs, stable isotopic ratios of oxygen-18 and deuterium, inorganic solute concentrations and total number of prokaryotes were determined on all water samples. Residence time of spring water ranged from 0 to 16 years in all regions, and storage volume of the groundwater within topographical watershed was estimated to be 0.1 m to 222 m in water height. The spring with the longer residence time tends to have larger storage volume in the watershed, and the spring underlain by dacite tends to have larger storage volume as compared with that underlain by sand stone and chert. Also, total number of prokaryotes in the spring water ranged from 103 to 105 cells/mL, and the spring tends to show clear increasing of total number of prokaryotes with decreasing of residence time. Thus, we observed a certain relationship among residence time, storage volume and total number of prokaryotes in the spring water, and

  8. Stability of arsenic compounds in seafood samples during processing and storage by freezing

    DEFF Research Database (Denmark)

    Dahl, Lisbeth; Molin, Marianne; Amlund, Heidi

    2010-01-01

    was observed after processing or after storage by freezing. The content of tetramethylarsonium ion was generally low in all samples types, but increased significantly in all fried samples of both fresh and frozen seafood. Upon storage by freezing, the arsenobetaine content was reduced significantly, but only...

  9. Time course of surface characteristics of alkali- and heat-treated titanium dental implants during vacuum storage.

    Science.gov (United States)

    Kamo, Michimasa; Kyomoto, Masayuki; Miyaji, Fumiaki

    2017-08-01

    Current efforts to shorten the healing times of life-long dental implants and prevent their fouling by organic impurities have focused on using surface-modification treatments and alternative packaging, respectively. In this study, we investigated the time course of the surface characteristics, including the wettability, a protein-adsorption and apatite-formation abilities, of alkali- and heat-treated (AH-treated) Ti samples during storage in vacuum over a period of 52 weeks. The AH treatment resulted in the formation of a nanometer-scale needle-like rougher surface of the Ti samples. Although the water contact angle of the AH-treated Ti sample increased slightly, it remained as low as approximately 10° even after storage in vacuum for 52 weeks. There was no significant difference in the protein-adsorption and apatite-formation abilities of the AH-treated Ti sample before and after storage. Further, the AH-treated Ti sample exhibited greater protein-adsorption and apatite-formation abilities compared with the untreated one; regardless of the samples stored in vacuum or not. Apatite formed only on the AH-treated Ti surface. Therefore, subjecting Ti dental implants to the AH treatment and storing them in vacuum should help prevent their surfaces from getting contaminated. Further, it is expected that AH-treated Ti dental implants controllably aged during a shelf storage will exhibit high stability and bone-bonding bioactivity. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1453-1460, 2017. © 2016 Wiley Periodicals, Inc.

  10. Reproducibility of NMR analysis of urine samples: impact of sample preparation, storage conditions, and animal health status.

    Science.gov (United States)

    Schreier, Christina; Kremer, Werner; Huber, Fritz; Neumann, Sindy; Pagel, Philipp; Lienemann, Kai; Pestel, Sabine

    2013-01-01

    Spectroscopic analysis of urine samples from laboratory animals can be used to predict the efficacy and side effects of drugs. This employs methods combining (1)H NMR spectroscopy with quantification of biomarkers or with multivariate data analysis. The most critical steps in data evaluation are analytical reproducibility of NMR data (collection, storage, and processing) and the health status of the animals, which may influence urine pH and osmolarity. We treated rats with a solvent, a diuretic, or a nephrotoxicant and collected urine samples. Samples were titrated to pH 3 to 9, or salt concentrations increased up to 20-fold. The effects of storage conditions and freeze-thaw cycles were monitored. Selected metabolites and multivariate data analysis were evaluated after (1)H NMR spectroscopy. We showed that variation of pH from 3 to 9 and increases in osmolarity up to 6-fold had no effect on the quantification of the metabolites or on multivariate data analysis. Storage led to changes after 14 days at 4°C or after 12 months at -20°C, independent of sample composition. Multiple freeze-thaw cycles did not affect data analysis. Reproducibility of NMR measurements is not dependent on sample composition under physiological or pathological conditions.

  11. Reproducibility of NMR Analysis of Urine Samples: Impact of Sample Preparation, Storage Conditions, and Animal Health Status

    Directory of Open Access Journals (Sweden)

    Christina Schreier

    2013-01-01

    Full Text Available Introduction. Spectroscopic analysis of urine samples from laboratory animals can be used to predict the efficacy and side effects of drugs. This employs methods combining 1H NMR spectroscopy with quantification of biomarkers or with multivariate data analysis. The most critical steps in data evaluation are analytical reproducibility of NMR data (collection, storage, and processing and the health status of the animals, which may influence urine pH and osmolarity. Methods. We treated rats with a solvent, a diuretic, or a nephrotoxicant and collected urine samples. Samples were titrated to pH 3 to 9, or salt concentrations increased up to 20-fold. The effects of storage conditions and freeze-thaw cycles were monitored. Selected metabolites and multivariate data analysis were evaluated after 1H NMR spectroscopy. Results. We showed that variation of pH from 3 to 9 and increases in osmolarity up to 6-fold had no effect on the quantification of the metabolites or on multivariate data analysis. Storage led to changes after 14 days at 4°C or after 12 months at −20°C, independent of sample composition. Multiple freeze-thaw cycles did not affect data analysis. Conclusion. Reproducibility of NMR measurements is not dependent on sample composition under physiological or pathological conditions.

  12. Computer system for environmental sample analysis and data storage and analysis

    International Nuclear Information System (INIS)

    Brauer, F.P.; Fager, J.E.

    1976-01-01

    A mini-computer based environmental sample analysis and data storage system has been developed. The system is used for analytical data acquisition, computation, storage of analytical results, and tabulation of selected or derived results for data analysis, interpretation and reporting. This paper discussed the structure, performance and applications of the system

  13. FIELD-DEPLOYABLE SAMPLING TOOLS FOR SPENT NUCLEAR FUEL INTERROGATION IN LIQUID STORAGE

    Energy Technology Data Exchange (ETDEWEB)

    Berry, T.; Milliken, C.; Martinez-Rodriguez, M.; Hathcock, D.; Heitkamp, M.

    2012-09-12

    Methodology and field deployable tools (test kits) to analyze the chemical and microbiological condition of aqueous spent fuel storage basins and determine the oxide thickness on the spent fuel basin materials were developed to assess the corrosion potential of a basin. this assessment can then be used to determine the amount of time fuel has spent in a storage basin to ascertain if the operation of the reactor and storage basin is consistent with safeguard declarations or expectations and assist in evaluating general storage basin operations. The test kit was developed based on the identification of key physical, chemical and microbiological parameters identified using a review of the scientific and basin operations literature. The parameters were used to design bench scale test cells for additional corrosion analyses, and then tools were purchased to analyze the key parameters. The tools were used to characterize an active spent fuel basin, the Savannah River Site (SRS) L-Area basin. The sampling kit consisted of a total organic carbon analyzer, an YSI multiprobe, and a thickness probe. The tools were field tested to determine their ease of use, reliability, and determine the quality of data that each tool could provide. Characterization confirmed that the L Area basin is a well operated facility with low corrosion potential.

  14. The requirement for proper storage of nuclear and related decommissioning samples to safeguard accuracy of tritium data.

    Science.gov (United States)

    Kim, Daeji; Croudace, Ian W; Warwick, Phillip E

    2012-04-30

    Large volumes of potentially tritium-contaminated waste materials are generated during nuclear decommissioning that require accurate characterisation prior to final waste sentencing. The practice of initially determining a radionuclide waste fingerprint for materials from an operational area is often used to save time and money but tritium cannot be included because of its tendency to be chemically mobile. This mobility demands a specific measurement for tritium and also poses a challenge in terms of sampling, storage and reliable analysis. This study shows that the extent of any tritium redistribution during storage will depend on its form or speciation and the physical conditions of storage. Any weakly or moderately bound tritium (e.g. adsorbed water, waters of hydration or crystallisation) may be variably lost at temperatures over the range 100-300 °C whereas for more strongly bound tritium (e.g. chemically bound or held in mineral lattices) the liberation temperature can be delayed up to 800 °C. For tritium that is weakly held the emanation behaviour at different temperatures becomes particularly important. The degree of (3)H loss and cross-contamination that can arise after sampling and before analysis can be reduced by appropriate storage. Storing samples in vapour tight containers at the point of sampling, the use of triple enclosures, segregating high activity samples and using a freezer all lead to good analytical practice. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. The effect of gamma irradiation and frozen storage time on the quality of tiger shrimps (Penaeus Monodon)

    International Nuclear Information System (INIS)

    Mohamad Khan Ayob; Azizah Ali; Jalil Kadir

    1986-01-01

    The effect of gamma irradiation (0, 1, 2, 4 and kGy) and frozen storage (-10 0 C) of 6 months on the microbiological, chemical and organoleptic qualities of whole (WSI) and peeled (PS2) tiger shrimps (Peneaus monodon) were studied. The qualities of the products were compared with blanched shrimps (PSI) ordinarily prepared at a factory. The irradiation dose up to 6 kGy reduced the total bacterial count (TBC) by at least 3 log cycles with D value = 2.13 kGy. The survival of pathogenic microbes was effectively retarded. Although blanching eliminated the pathogenic microbes, the TBC of PSI before storage is still in a range of 10 5 /g. There was an increase in TBC of 1-2 log cycles during storage in all samples. Peeling effectively reduced the TBC of the shrimps. Gamma irradiation and shorter period of storage time did not influence the pH and protein contents of the products. Indole production was slowed down by irradiation at 1-4 kGy, which is comparable to blanching treatment. Organoleptic qualities (colour, ordour and texture) of the products were not effected by irradiation and storage time except for samples irradiated at 6 kGy in which the pink colour faded. There was no significant difference in the organoleptic qualities of irradiated (2 kGy) samples as compared to blanched products. (author)

  16. Effect of sample type, centrifugation and storage conditions on vitamin D concentration.

    Science.gov (United States)

    Colak, Ayfer; Toprak, Burak; Dogan, Nese; Ustuner, Fusun

    2013-01-01

    Studies about vitamin D [25(OH)D] stability in plasma are limited and preanalytical variables such as tube type may affect results. We aimed to evaluate effect of storage conditions, sample type and some preanalytical variables on vitamin D concentration. Blood samples from 15 healthy subjects were centrifuged at different temperatures and stored under different conditions. Serum and plasma 25(OH)D difference, effect of centrifugation temperature and common storage conditions were investigated. There was no difference between serum and plasma vitamin D concentration. Centrifugation temperature had no impact on vitamin D concentration. 25(OH)D is stable under common storage conditions: 4 hours at room temperature, 24 hours at 2-8 degrees C, 7 days at -20 degrees C, 3 months at -80 degrees C. Vitamin D does not require any special storage conditions and refrigeration. Both serum and plasma can be used for measurement.

  17. Optimization of time and location dependent spent nuclear fuel storage capacity

    International Nuclear Information System (INIS)

    Macek, V.

    1977-01-01

    A linear spent fuel storage model is developed to identify cost-effective spent nuclear fuel storage strategies. The purpose of this model is to provide guidelines for the implementation of the optimal time-dependent spent fuel storage capacity expansion in view of the current economic and regulatory environment which has resulted in phase-out of the closed nuclear fuel cycle. Management alternatives of the spent fuel storage backlog, which is created by mismatch between spent fuel generation rate and spent fuel disposition capability, are represented by aggregate decision variables which describe the time dependent on-reactor-site and off-site spent fuel storage capacity additions, and the amount of spent fuel transferred to off-site storage facilities. Principal constraints of the model assure determination of cost optimal spent fuel storage expansion strategies, while spent fuel storage requirements are met at all times. A detailed physical and economic analysis of the essential components of the spent fuel storage problem, which precedes the model development, assures its realism. The effects of technological limitations on the on-site spent fuel storage expansion and timing of reinitiation of the spent fuel reprocessing on optimal spent fuel storage capacity expansion are investigated. The principal results of the study indicate that (a) expansion of storage capacity beyond that of currently planned facilities is necessary, and (b) economics of the post-reactor fuel cycle is extremely sensitive to the timing of reinitiation of spent fuel reprocessing. Postponement of reprocessing beyond mid-1982 may result in net negative economic liability of the back end of the nuclear fuel cycle

  18. Inactivation kinetics of Vibrio vulnificus in phosphate-buffered saline at different freezing and storage temperatures and times.

    Science.gov (United States)

    Seminario, Diana M; Balaban, Murat O; Rodrick, Gary

    2011-03-01

    Vibrio vulnificus (Vv) is a pathogen that can be found in raw oysters. Freezing can reduce Vv and increase the shelf life of oysters. The objective of this study was to develop predictive inactivation kinetic models for pure cultures of Vv at different frozen storage temperatures and times. Vv was diluted in phosphate-buffered saline (PBS) to obtain about 10(7) CFU/mL. Samples were frozen at -10, -35, and -80 °C (different freezing rates), and stored at different temperatures. Survival of Vv was followed after freezing and storage at -10 °C (0, 3, 6, and 9 d) and at -35 and -80 °C (every week for 6 wk). For every treatment, time-temperature data was obtained using thermocouples in blank vials. Predictive models were developed using first-order, Weibull and Peleg inactivation kinetics. Different freezing temperatures did not significantly (α = 0.05) affect survival of Vv immediately after freezing. The combined effect of freezing and 1 wk frozen storage resulted in 1.5, 2.6, and 4.9 log10 reductions for samples stored at -80, -35, and -10 °C, respectively. Storage temperature was the critical parameter in survival of Vv. A modified Weibull model successfully predicted Vv survival during frozen storage: log10 Nt = log 10No - 1.22 - ([t/10{-1.163-0.0466T}][0.00025T(2) + 0.049325]). N(o) and N(t) are initial and time t (d) survival counts, T is frozen storage temperature, Celsius degree. Vibrio vulnificus can be inactivated by freezing. Models to predict survival of V. vulnificus at different freezing temperatures and times were developed. This is the first step towards the prediction of V. vulnificus related safety of frozen oysters.

  19. Molecular solar thermal energy storage in photoswitch oligomers increases energy densities and storage times.

    Science.gov (United States)

    Mansø, Mads; Petersen, Anne Ugleholdt; Wang, Zhihang; Erhart, Paul; Nielsen, Mogens Brøndsted; Moth-Poulsen, Kasper

    2018-05-16

    Molecular photoswitches can be used for solar thermal energy storage by photoisomerization into high-energy, meta-stable isomers; we present a molecular design strategy leading to photoswitches with high energy densities and long storage times. High measured energy densities of up to 559 kJ kg -1 (155 Wh kg -1 ), long storage lifetimes up to 48.5 days, and high quantum yields of conversion of up to 94% per subunit are demonstrated in norbornadiene/quadricyclane (NBD/QC) photo-/thermoswitch couples incorporated into dimeric and trimeric structures. By changing the linker unit between the NBD units, we can at the same time fine-tune light-harvesting and energy densities of the dimers and trimers so that they exceed those of their monomeric analogs. These new oligomers thereby meet several of the criteria to be met for an optimum molecule to ultimately enter actual devices being able to undergo closed cycles of solar light-harvesting, energy storage, and heat release.

  20. The U-tube sampling methodology and real-time analysis of geofluids

    International Nuclear Information System (INIS)

    Freifeld, Barry; Perkins, Ernie; Underschultz, James; Boreham, Chris

    2009-01-01

    The U-tube geochemical sampling methodology, an extension of the porous cup technique proposed by Wood (1973), provides minimally contaminated aliquots of multiphase fluids from deep reservoirs and allows for accurate determination of dissolved gas composition. The initial deployment of the U-tube during the Frio Brine Pilot CO 2 storage experiment, Liberty County, Texas, obtained representative samples of brine and supercritical CO 2 from a depth of 1.5 km. A quadrupole mass spectrometer provided real-time analysis of dissolved gas composition. Since the initial demonstration, the U-tube has been deployed for (1) sampling of fluids down gradient of the proposed Yucca Mountain High-Level Waste Repository, Armagosa Valley, Nevada (2) acquiring fluid samples beneath permafrost in Nunuvut Territory, Canada, and (3) at a CO 2 storage demonstration project within a depleted gas reservoir, Otway Basin, Victoria, Australia. The addition of in-line high-pressure pH and EC sensors allows for continuous monitoring of fluid during sample collection. Difficulties have arisen during U-tube sampling, such as blockage of sample lines from naturally occurring waxes or from freezing conditions; however, workarounds such as solvent flushing or heating have been used to address these problems. The U-tube methodology has proven to be robust, and with careful consideration of the constraints and limitations, can provide high quality geochemical samples.

  1. The zeatin content of tomatoes as a function of the degree of ripeness, irradiation and storage time

    International Nuclear Information System (INIS)

    Kovacs, E.; Voeroes, Zs.

    1975-01-01

    The zeatin content of the San Marzano variety tomatoes was studied as a function of their degree of ripeness (fruitlet, green fruit, pink fruit, red fruit), storage time (at 20-23 deg C and 40-50% RH) and radiation treatment (4 krad). The zeatin content of tomatoes determined by thin-layer chromatography decreased with the advancement of ripening. The zeatin content of freshly picked pink tomatoes increased immediately upon radiation treatment with 4 krad. After 9 day storage the zeatin content of both irradiated and untreated tomato samples decreased during the 9-day storage time. On the 9th day the zeatin content of the irradiated tomatoes was 20% higher than that of the untreated ones. (F.J.)

  2. Degradation of hydrocarbons in soil samples analyzed within accepted analytical holding times

    International Nuclear Information System (INIS)

    Jackson, J.; Thomey, N.; Dietlein, L.F.

    1992-01-01

    Samples which are collected in conjunction with subsurface investigations at leaking petroleum storage tank sites and petroleum refineries are routinely analyzed for benzene, toluene, ethylbenzene, xylenes (BTEX), and total petroleum hydrocarbons (TPH). Water samples are preserved by the addition of hydrochloric acid and maintained at four degrees centigrade prior to analysis. This is done to prevent bacterial degradation of hydrocarbons. Chemical preservation is not presently performed on soil samples. Instead, the samples are cooled and maintained at four degrees centigrade. This study was done to measure the degree of degradation of hydrocarbons in soil samples which are analyzed within accepted holding times. Soil samples were collected and representative subsamples were prepared from the initial sample. Subsamples were analyzed in triplicate for BTEX and TPH throughout the length of the approved holding times to measure the extent of sample constituent degradation prior to analysis. Findings imply that for sandy soils, BTEX and TPH concentrations can be highly dependent upon the length of time which elapses between sample collection and analysis

  3. Monitoring of quality and storage time of unsealed pasteurized milk by voltammetric electronic tongue

    International Nuclear Information System (INIS)

    Wei, Zhenbo; Wang, Jun; Zhang, Xi

    2013-01-01

    A voltammetric electronic tongue (VE-tongue) was self-developed and applied to monitor the quality and storage time of unsealed pasteurized milk. The VE-tongue comprised four working electrodes: gold, silver, platinum, and palladium electrode. Two potential waveforms: Multi-frequency rectangle pulse voltammetry (MRPV) and multi-frequency staircase pulse voltammetry (MSPV) were applied to working electrodes in the study, and both of MRPV and MSPV consisted of three frequency segments: 1 Hz, 10 Hz, and 100 Hz. The total areas under the corresponding curves obtained by VE-tongue in the three frequencies were applied as characteristic data, which were evaluated by the principal component analysis (PCA) and cluster analysis (CA). The results of PCA and CA indicate that the milk samples of different storage time could be successfully classified by the VE-tongue based on MRPV and MSPV, respectively. Combining the areas obtained by the VE-tongue based on MRPV and MSPV, the classification results of PCA and CA were improved evidently. The total bacterial count, acidity and viscosity of the milk samples were also measured during the storage, and those physicochemical characteristics showed regular configuration in PCA and CA plots. Furthermore, the total bacterial count and viscosity properties were predicted by partial least squares regression (PLSR) and least squares-support vector machines (LS-SVM), and the combination of the areas obtained by the VE-tongue based on the MRPV and MSPV were applied as the input data of PLSR and LS-SVM. Both the prediction techniques performed well in predicting viscosity and total bacterial count, and the prediction results of LS-SVM were better than that of PLSR. Those results demonstrate that the VE-tongue could be applied to monitor the quality storage time of unsealed pasteurized milk

  4. Post-cold-storage conditioning time affects soil denitrifying enzyme activity

    DEFF Research Database (Denmark)

    Chirinda, Ngonidzashe; Olesen, Jørgen Eivind; Porter, John Roy

    2011-01-01

    Soil denitrifying enzyme activity (DEA) is often assessed after cold storage. Previous studies using the short-term acetylene inhibition method have not considered conditioning time (post-cold-storage warm-up time prior to soil analysis) as a factor influencing results. We observed fluctuations...

  5. Influence of Freezing and Storage Procedure on Human Urine Samples in NMR-Based Metabolomics

    OpenAIRE

    Rist, Manuela; Muhle-Goll, Claudia; Görling, Benjamin; Bub, Achim; Heissler, Stefan; Watzl, Bernhard; Luy, Burkhard

    2013-01-01

    It is consensus in the metabolomics community that standardized protocols should be followed for sample handling, storage and analysis, as it is of utmost importance to maintain constant measurement conditions to identify subtle biological differences. The aim of this work, therefore, was to systematically investigate the influence of freezing procedures and storage temperatures and their effect on NMR spectra as a potentially disturbing aspect for NMR-based metabolomics studies. Urine sample...

  6. Irradiation control of pathogenic bacteria and their growth during storage time in cooled chicken

    International Nuclear Information System (INIS)

    Ha Yiming; Wang Feng; Fan Bei; Liu Shuliang; Ju Hua

    2009-01-01

    The growth of pathogenic bacteria during storage time and their D 10 values by irradiation in cooled chicken were evaluated. The total numbers of colony, E.coli 10003, Campylobacter jejuni33560 and CY04 of the D 10 values were 1.434 kGy, 0.408 kGy, 0.175 kGy, 0.2 kGy respectively in cooled chicken. The results show that total bacteria count in vacuum packaged cooled chicken sample is 5.66 lg(CFU/g) and 4.90 lg (CFU/g) after 3 kGy and 5 kGy irradiation. And in storage at 0∼4 degree C the storage shelf-life of irradiated vacuum packaged cooled chicken could extend to 21 d and 28 d. It can be deduced that pathogenic bacteria can be controlled effectively by irradiation. (authors)

  7. Time to rethink nuclear waste storage

    International Nuclear Information System (INIS)

    Flynn, J.; Kasperson, R.; Kunreuther, H.; Slovic, P.

    1992-01-01

    The authors feel that given the levels of public opposition and distrust, congress should scrap the current nuclear waste storage program and reconsider the options. They observe that no compelling reason currently exists for siting a permanent repository at an early date. Technology developed in the past decade, especially dry-cask storage, provides assurance that wastes from commercial reactors can be stored safely for a lengthy period at current sites. In the longer term, reprocessing may reduce the volume of high-level wastes; storage elsewhere than in a geological repository may prove attractive; and experimental techniques such as transmutation - aimed at radically reducing the amount of time that wastes remain highly radioactive - could help solve the problem. In the meantime, the authors suggest that the US must begin a long-term effort to engage the public in a process of active collaboration. In doing so, the US has much to learn from other countries, where innovative approaches and techniques have began to establish public confidence

  8. Long-Time Data Storage: Relevant Time Scales

    Directory of Open Access Journals (Sweden)

    Miko C. Elwenspoek

    2011-02-01

    Full Text Available Dynamic processes relevant for long-time storage of information about human kind are discussed, ranging from biological and geological processes to the lifecycle of stars and the expansion of the universe. Major results are that life will end ultimately and the remaining time that the earth is habitable for complex life is about half a billion years. A system retrieved within the next million years will be read by beings very closely related to Homo sapiens. During this time the surface of the earth will change making it risky to place a small number of large memory systems on earth; the option to place it on the moon might be more favorable. For much longer timescales both options do not seem feasible because of geological processes on the earth and the flux of small meteorites to the moon.

  9. Comparison of three media for transport and storage of the samples collected for detection of avian influenza virus.

    Science.gov (United States)

    Zhang, Xiao-Chun; Liu, Shuo; Hou, Guang-Yu; Zhuang, Qing-Ye; Wang, Kai-Cheng; Jiang, Wen-Ming; Wang, Su-Chun; Li, Jin-Ping; Yu, Jian-Min; Du, Xiang; Huang, Bao-Xu; Chen, Ji-Ming

    2015-09-15

    Detection of avian influenza viruses (AIVs) is important for diagnosis, surveillance and control of avian influenza which is of great economic and public health significance. Proper transport and storage of samples is critical for the detection when the samples cannot be detected immediately. As recommended by some international or national authoritative entities and some publications, phosphate buffered saline (PBS), PBS-glycerol and brain heart infusion broth (BHIB) are frequently used for transport and storage of the samples collected for detection of AIVs worldwide. In this study, we compared these three media for transport and storage of simulated and authentic swab and feces samples collected for detection of AIVs using virus isolation and reverse transcription-PCR. The results suggest that PBS-glycerol is superior to PBS and BHIB as the sample transport and storage media. The results also suggest that the samples collected for detection of AIVs should be detected as soon as possible because the virus concentration of the samples may decline rapidly during storage within days at 4 or -20°C. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Gas chromatographic-mass spectrometric analysis of urinary volatile organic metabolites: Optimization of the HS-SPME procedure and sample storage conditions.

    Science.gov (United States)

    Živković Semren, Tanja; Brčić Karačonji, Irena; Safner, Toni; Brajenović, Nataša; Tariba Lovaković, Blanka; Pizent, Alica

    2018-01-01

    Non-targeted metabolomics research of human volatile urinary metabolome can be used to identify potential biomarkers associated with the changes in metabolism related to various health disorders. To ensure reliable analysis of urinary volatile organic metabolites (VOMs) by gas chromatography-mass spectrometry (GC-MS), parameters affecting the headspace-solid phase microextraction (HS-SPME) procedure have been evaluated and optimized. The influence of incubation and extraction temperatures and times, coating fibre material and salt addition on SPME efficiency was investigated by multivariate optimization methods using reduced factorial and Doehlert matrix designs. The results showed optimum values for temperature to be 60°C, extraction time 50min, and incubation time 35min. The proposed conditions were applied to investigate urine samples' stability regarding different storage conditions and freeze-thaw processes. The sum of peak areas of urine samples stored at 4°C, -20°C, and -80°C up to six months showed a time dependent decrease over time although storage at -80°C resulted in a slight non-significant reduction comparing to the fresh sample. However, due to the volatile nature of the analysed compounds, more than two cycles of freezing/thawing of the sample stored for six months at -80°C should be avoided whenever possible. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. 21 CFR 203.32 - Drug sample storage and handling requirements.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Drug sample storage and handling requirements. 203.32 Section 203.32 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... contamination, deterioration, and adulteration. (b) Compliance with compendial and labeling requirements...

  12. Long-term storage of samples for flow cytometric DNA analysis

    DEFF Research Database (Denmark)

    Vindeløv, L L; Christensen, I J; Keiding, N

    1983-01-01

    estimation by deconvolution, there was significant intraday and interday variation. Hence the most accurate results are obtained if different aliquots of a sample are measured on different days rather than on the same day. Use of the storage method thus has the potential of increasing the accuracy...

  13. Evaluation of storage and filtration protocols for alpine/subalpine lake water quality samples

    Science.gov (United States)

    John L. Korfmacher; Robert C. Musselman

    2007-01-01

    Many government agencies and other organizations sample natural alpine and subalpine surface waters using varying protocols for sample storage and filtration. Simplification of protocols would be beneficial if it could be shown that sample quality is unaffected. In this study, samples collected from low ionic strength waters in alpine and subalpine lake inlets...

  14. Effect of harvest time on storage loss and sprouting in onion

    Directory of Open Access Journals (Sweden)

    T. SUOJALA

    2008-12-01

    Full Text Available Storability of onion is affected by timing of harvest. However, the optimal time for maximum yield and maximum storability do not necessarily coincide. This study aimed to determine the most suitable harvest time for obtaining a high bulb yield with high quality and storability. Storage experiments were conducted on onions produced in field experiments at a research field and on farms in four years. Results indicate that harvesting could be delayed to 100% maturity, or even longer, without a marked increase in storage loss. In rainy years, late harvest is likely to impair the quality. The incidence of sprouting in shelf life tests varied considerably between years. An early harvest before 50% maturity and a delayed harvest increased the risk of sprouting. It may be concluded that the harvesting of onions for long-term storage can be timed to take place between 50% maturity and even some weeks after complete maturity without a loss in storage quality. Therefore, it is possible to combine high yield and good storage quality.

  15. Managing high-bandwidth real-time data storage

    Energy Technology Data Exchange (ETDEWEB)

    Bigelow, David D. [Los Alamos National Laboratory; Brandt, Scott A [Los Alamos National Laboratory; Bent, John M [Los Alamos National Laboratory; Chen, Hsing-Bung [Los Alamos National Laboratory

    2009-09-23

    There exist certain systems which generate real-time data at high bandwidth, but do not necessarily require the long-term retention of that data in normal conditions. In some cases, the data may not actually be useful, and in others, there may be too much data to permanently retain in long-term storage whether it is useful or not. However, certain portions of the data may be identified as being vitally important from time to time, and must therefore be retained for further analysis or permanent storage without interrupting the ongoing collection of new data. We have developed a system, Mahanaxar, intended to address this problem. It provides quality of service guarantees for incoming real-time data streams and simultaneous access to already-recorded data on a best-effort basis utilizing any spare bandwidth. It has built in mechanisms for reliability and indexing, can scale upwards to meet increasing bandwidth requirements, and handles both small and large data elements equally well. We will show that a prototype version of this system provides better performance than a flat file (traditional filesystem) based version, particularly with regard to quality of service guarantees and hard real-time requirements.

  16. Effects of storage time and straw content of cattle slurry on the mineralization of nitrogen and carbon in soil

    DEFF Research Database (Denmark)

    Sørensen, P.

    1998-01-01

    Animal slurries are stored for a variable period of time before application in the field. The effect of cattle slurry storage time and temperature on the subsequent mineralization of C and N in soil was studied under laboratory conditions. Urine and faeces from a dairy cow were sampled separately...... and mixed to a slurry. After 4 weeks of storage under anaerobic conditions at 15 degrees C, the NH4+ N content exceeded the original urinary N content of the slurry; the NH4+ content increased only slightly during the following 16 weeks of storage. After 4 weeks of storage, the proportion of slurry C...... in volatile fatty acids (VFA) amounted to 10% and increased to 15% after 20 weeks. Straw addition to the slurry caused an increase of VFA-C in stored slurry, but had a negligible influence on the proportion of slurry N in the form of NH4+. Slurries subjected to different storage conditions were added...

  17. Effect of gamma irradiation and storage on lutein and zeaxanthin in liquid, frozen and dried egg yolk samples

    International Nuclear Information System (INIS)

    Mine Uygun-Saribay; Ece Ergun; Turhan Koeseoglu

    2014-01-01

    The aim of this study was to monitor the effects of gamma irradiation and storage on the content of lutein and zeaxanthin in egg yolk samples. Liquid, frozen and dried egg samples were subjected to gamma irradiation doses of 0, 1, 2 and 3 kGy followed by storage of liquid samples at +4 ± 1 deg C for 21 days, frozen samples at -18 ± 1 deg C and dried samples at room temperature for 1 year. The xanthophyll concentrations were determined by high-performance liquid chromatography-diode array detector. It was observed that concentrations of both lutein and zeaxanthin were decreased significantly (P < 0.05) after irradiation and during storage. The mechanism for radiation-induced degradation was proposed as radical formation which initiate chain reactions. It was suggested that during storage active radical species and oxygen caused the degradation. (author)

  18. A flexible system to capture sample vials in a storage box - the box vial scanner.

    Science.gov (United States)

    Nowakowski, Steven E; Kressin, Kenneth R; Deick, Steven D

    2009-01-01

    Tracking sample vials in a research environment is a critical task and doing so efficiently can have a large impact on productivity, especially in high volume laboratories. There are several challenges to automating the capture process, including the variety of containers used to store samples. We developed a fast and robust system to capture the location of sample vials being placed in storage that allows the laboratories the flexibility to use sample containers of varying dimensions. With a single scan, this device captures the box identifier, the vial identifier and the location of each vial within a freezer storage box. The sample vials are tracked through a barcode label affixed to the cap while the boxes are tracked by a barcode label on the side of the box. Scanning units are placed at the point of use and forward data to a sever application for processing the scanned data. Scanning units consist of an industrial barcode reader mounted in a fixture positioning the box for scanning and providing lighting during the scan. The server application transforms the scan data into a list of storage locations holding vial identifiers. The list is then transferred to the laboratory database. The box vial scanner captures the IDs and location information for an entire box of sample vials into the laboratory database in a single scan. The system accommodates a wide variety of vials sizes by inserting risers under the sample box and a variety of storage box layouts are supported via the processing algorithm on the server.

  19. Effect of storage conditions on the weight and appearance of dried blood spot samples on various cellulose-based substrates.

    Science.gov (United States)

    Denniff, Philip; Spooner, Neil

    2010-11-01

    Before shipping and storage, dried blood spot (DBS) samples must be dried in order to protect the integrity of the spots. In this article, we examine the time required to dry blood spot samples and the effects of different environmental conditions on their integrity. Under ambient laboratory conditions, DBS samples on Whatman 903(®), FTA(®) and FTA(®) Elute substrates are dry within 90 min of spotting. An additional 5% of moisture is lost during subsequent storage with desiccant. When exposed to elevated conditions of temperature and relative humidity, the DBS samples absorb moisture. DBS samples on FTA lose this moisture on being returned to ambient conditions. DBS samples on 903 show no visible signs of deterioration when stored at elevated conditions. However, these conditions cause the DBS to diffuse through the FTA Elute substrate. Blood spots are dry within 90 min of spotting. However, the substrates examined behave differently when exposed to conditions of high relative humidity and temperature, in some cases resulting in the integrity of the substrate and DBS sample being compromised. It is recommended that these factors be investigated as part of method development and validation.

  20. Soil Sampling Plan for the transuranic storage area soil overburden and final report: Soil overburden sampling at the RWMC transuranic storage area

    International Nuclear Information System (INIS)

    Stanisich, S.N.

    1994-12-01

    This Soil Sampling Plan (SSP) has been developed to provide detailed procedural guidance for field sampling and chemical and radionuclide analysis of selected areas of soil covering waste stored at the Transuranic Storage Area (TSA) at the Idaho National Engineering Laboratory's (INEL) Radioactive Waste Management Complex (RWMC). The format and content of this SSP represents a complimentary hybrid of INEL Waste Management--Environmental Restoration Program, and Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) Remedial Investigation/Feasibility Study (RI/FS) sampling guidance documentation. This sampling plan also functions as a Quality Assurance Project Plan (QAPP). The QAPP as a controlling mechanism during sampling to ensure that all data collected are valid, reliabile, and defensible. This document outlines organization, objectives and quality assurance/quality control (QA/QC) activities to achieve the desired data quality goals. The QA/QC requirements for this project are outlined in the Data Collection Quality Assurance Plan (DCQAP) for the Buried Waste Program. The DCQAP is a program plan and does not outline the site specific requirements for the scope of work covered by this SSP

  1. Effect of storage time at -20°C on markers used for assessment of renal damage in children: albumin, γ-glutamyl transpeptidase, N-acetyl-β-D-glucosaminidase and α1-microglobulin.

    Science.gov (United States)

    Trachtenberg, Felicia; Barregard, Lars

    2010-11-01

    The objective of this study is to examine the influence of storage time at -20°C on the concentration of albumin, γ-glutamyl transpeptidase (γ-GT), N-acetyl-β-D-glucosaminidase (NAG), α(1)-microglobulin (A1M) and creatinine in a large sample of healthy children. The New England Children's Amalgam Trial followed 534 children, aged 6-10 at baseline, for 5 years, with annual urine collections. Urine samples were analysed for creatinine, albumin, γ-GT, NAG and A1M concentrations. Repeated measures analysis of covariance was used to model the effect of storage time on these concentrations. The γ-GT concentration decreased significantly with storage time at -20°C. There was also a limited decrease in NAG. Albumin, A1M and creatinine concentrations did not appear to be affected by storage time at -20°C. If it is necessary to interpret results from samples stored for a long time at -20°C, it is advisable to account for storage time in statistical models.

  2. Portable ultrahigh-vacuum sample storage system for polarization-dependent total-reflection fluorescence x-ray absorption fine structure spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Yoshihide, E-mail: e0827@mosk.tytlabs.co.jp; Nishimura, Yusaku F.; Suzuki, Ryo; Beniya, Atsushi; Isomura, Noritake [Toyota Central R& D Labs., Inc., Yokomichi 41-1, Nagakute, Aichi 480-1192 (Japan); Uehara, Hiromitsu; Asakura, Kiyotaka; Takakusagi, Satoru [Catalysis Research Center, Hokkaido University, Kita 21-10, Sapporo, Hokkaido 001-0021 (Japan); Nimura, Tomoyuki [AVC Co., Ltd., Inada 1450-6, Hitachinaka, Ibaraki 312-0061 (Japan)

    2016-03-15

    A portable ultrahigh-vacuum sample storage system was designed and built to investigate the detailed geometric structures of mass-selected metal clusters on oxide substrates by polarization-dependent total-reflection fluorescence x-ray absorption fine structure spectroscopy (PTRF-XAFS). This ultrahigh-vacuum (UHV) sample storage system provides the handover of samples between two different sample manipulating systems. The sample storage system is adaptable for public transportation, facilitating experiments using air-sensitive samples in synchrotron radiation or other quantum beam facilities. The samples were transferred by the developed portable UHV transfer system via a public transportation at a distance over 400 km. The performance of the transfer system was demonstrated by a successful PTRF-XAFS study of Pt{sub 4} clusters deposited on a TiO{sub 2}(110) surface.

  3. Effect of pressing and combination of three storage temperatures and times on chemical composition and fatty acid profile of canola expellers

    Directory of Open Access Journals (Sweden)

    Matteo Guadagnin

    2013-05-01

    Full Text Available This experiment investigated the effects of combinations of three temperatures and storage times on chemical composition, fatty acid profile, and oxidative stability of canola expellers obtained from the cold-pressing extraction of oil. Canola seeds were single-crushed at moderate temperatures (60°C during 3 pressing sessions. Nine samples (100±1 g of each session were collected, inserted into sealed bags, stored at three temperatures (12, 24, 36°C over 3 periods of time (10, 20, 30 d. Then, samples (100±1 g of canola seeds collected before each pressing session and canola expellers collected before and after each storage time were analyzed for chemical composition, fatty acid profile, peroxide number and Kreis test. Before storage, the fatty acid profile of canola seeds and expellers differed significantly, except for myristic (P=0.18, palmitic (P=0.57, oleic (P=0.07, and α-linolenic acids (P=0.45. Compared to canola seeds, expellers showed greater content of saturated, poly-unsaturated, and n-6 fatty acids (P<0.01, but a lower content of mono-unsaturated fatty acids (P<0.01. Peroxide values were definitely (P<0.01 greater for expellers and averaged 4.22 and 4.11 mEq/kg fat before and after storage, respectively. The Kreis test was negative for all samples. Under different temperatures and times of storage, canola expellers showed to maintain a good oxidative stability, as highlighted by low peroxide values (<10 mEq/kg fat and negative response for Kreis test. Canola expellers obtained by on-farm cold extraction, despite great oil residual (from 17 to 19% ether extracts on dry matter basis, can be stored at farm without significant chemical and nutritional changes.

  4. Effect of storage time and temperature of equine feces on the subsequent enumeration of lactobacilli and cellulolytic bacteria

    Science.gov (United States)

    Cellulolytic bacteria and lactobacilli are beneficial microbes in the equine hindgut. There are several existing methodologies for the enumeration of these bacteria, which vary based on selective and differential media and sample handling procedures including storage time and temperature. The object...

  5. Storage capacity and retrieval time of small-world neural networks

    International Nuclear Information System (INIS)

    Oshima, Hiraku; Odagaki, Takashi

    2007-01-01

    To understand the influence of structure on the function of neural networks, we study the storage capacity and the retrieval time of Hopfield-type neural networks for four network structures: regular, small world, random networks generated by the Watts-Strogatz (WS) model, and the same network as the neural network of the nematode Caenorhabditis elegans. Using computer simulations, we find that (1) as the randomness of network is increased, its storage capacity is enhanced; (2) the retrieval time of WS networks does not depend on the network structure, but the retrieval time of C. elegans's neural network is longer than that of WS networks; (3) the storage capacity of the C. elegans network is smaller than that of networks generated by the WS model, though the neural network of C. elegans is considered to be a small-world network

  6. Effect of temperature and time of pasteurization on the milk quality during storage

    Directory of Open Access Journals (Sweden)

    Abubakar

    2001-03-01

    Full Text Available A study on the effect of temperature and time of pasteurization on the milk quality during storage was carried out using fresh milk. The aim of the experiment was to asses the storage time of pasteurized milk for consumption without nutrient losses. A completely randomized factorial design, 2 x 8 was used, with pasteurization temperature (T, consisted of 2 levels, the low temperature long time (LTLT, i.e. fresh milk was warmed at 65oC for 30 minutes (T1 and the high temperature short time (HTST, i.e. fresh milk was warmed at 71oC for 15 seconds (T2; and storage time (S, consisted of 8 levels, i.e. 0, 3, 6, 9, 12, 15, 18, and 21 hours respectively, as the factors, with 3 replicates. Parameters measured were alcohol test, water, fat, and protein concentrations, and microbial population of pasteurized milk during storage. Data were analyzed using analysis of variance and simple linear regression. The result showed that water and fat concentrations and microbial population was not significantly different (P>0.05 in pasteurization temperature treatment, but was significantly different (P<0.05 due to storage time treatment. Meanwhile, the protein concentration was significantly different (P<0.05 either in pasteurization temperature or storage time. It was concluded that pasteurized milk was still suitable for consumption at 15-21 hours storage, while protein concentration tended to be better when was pasteurized at 65oC.

  7. Influence of Freezing and Storage Procedure on Human Urine Samples in NMR-Based Metabolomics

    Directory of Open Access Journals (Sweden)

    Burkhard Luy

    2013-04-01

    Full Text Available It is consensus in the metabolomics community that standardized protocols should be followed for sample handling, storage and analysis, as it is of utmost importance to maintain constant measurement conditions to identify subtle biological differences. The aim of this work, therefore, was to systematically investigate the influence of freezing procedures and storage temperatures and their effect on NMR spectra as a potentially disturbing aspect for NMR-based metabolomics studies. Urine samples were collected from two healthy volunteers, centrifuged and divided into aliquots. Urine aliquots were frozen either at −20 °C, on dry ice, at −80 °C or in liquid nitrogen and then stored at −20 °C, −80 °C or in liquid nitrogen vapor phase for 1–5 weeks before NMR analysis. Results show spectral changes depending on the freezing procedure, with samples frozen on dry ice showing the largest deviations. The effect was found to be based on pH differences, which were caused by variations in CO2 concentrations introduced by the freezing procedure. Thus, we recommend that urine samples should be frozen at −20 °C and transferred to lower storage temperatures within one week and that freezing procedures should be part of the publication protocol.

  8. Influence of Freezing and Storage Procedure on Human Urine Samples in NMR-Based Metabolomics.

    Science.gov (United States)

    Rist, Manuela J; Muhle-Goll, Claudia; Görling, Benjamin; Bub, Achim; Heissler, Stefan; Watzl, Bernhard; Luy, Burkhard

    2013-04-09

    It is consensus in the metabolomics community that standardized protocols should be followed for sample handling, storage and analysis, as it is of utmost importance to maintain constant measurement conditions to identify subtle biological differences. The aim of this work, therefore, was to systematically investigate the influence of freezing procedures and storage temperatures and their effect on NMR spectra as a potentially disturbing aspect for NMR-based metabolomics studies. Urine samples were collected from two healthy volunteers, centrifuged and divided into aliquots. Urine aliquots were frozen either at -20 °C, on dry ice, at -80 °C or in liquid nitrogen and then stored at -20 °C, -80 °C or in liquid nitrogen vapor phase for 1-5 weeks before NMR analysis. Results show spectral changes depending on the freezing procedure, with samples frozen on dry ice showing the largest deviations. The effect was found to be based on pH differences, which were caused by variations in CO2 concentrations introduced by the freezing procedure. Thus, we recommend that urine samples should be frozen at -20 °C and transferred to lower storage temperatures within one week and that freezing procedures should be part of the publication protocol.

  9. Measurement of the time of storage of ultracold neutrons in a magnetic trap

    International Nuclear Information System (INIS)

    Abov, Y.G.; Borovlev, S.P.; Vasil'ev, V.V.; Vladimirskii, V.V.; Mospan, E.N.

    1983-01-01

    The storage time of ultracold neutrons in an axial magnetic trap with a simple singly connected confinement region is measured. It is shown that the storage of the neutrons is due just to the magnetic field. The storage time achieved is tau = 303 +- 37 sec. In a working cycle 3.6 neutrons are accumulated

  10. 40 CFR 273.53 - Storage time limits.

    Science.gov (United States)

    2010-07-01

    ...) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT Standards for Universal Waste Transporters § 273.53 Storage time limits. (a) A universal waste transporter may only store the universal waste at a universal waste transfer facility for ten days or less. (b) If a universal waste transporter stores universal waste for...

  11. Effect of packaging and storage time on survival of Listeria monocytogenes on kippered beef steak and turkey tenders.

    Science.gov (United States)

    Uppal, Kamaldeep K; Getty, Kelly J K; Boyle, Elizabeth A E; Harper, Nigel M; Lobaton-Sulabo, April Shayne S; Barry, Bruce

    2012-01-01

    The objective of our study was to determine effect of packaging method and storage time on reducing Listeria monocytogenes in shelf-stable meat snacks. Commercially available kippered beef steak strips and turkey tenders were dipped into a 5-strain L. monocytogenes cocktail, and dried at 23 °C until a water activity of 0.80 was achieved. Inoculated samples were packaged with 4 treatments: (1) vacuum, (2) nitrogen flushed with oxygen scavenger, (3) heat sealed with oxygen scavenger, and (4) heat sealed without oxygen scavenger. Samples were stored at 23 °C and evaluated for L. monocytogenes levels at 0, 24, 48, and 72 h. Initial levels (time 0) of L. monocytogenes were approximately 5.7 log CFU/cm² for steak and tenders. After 24 h of storage time, a 1 log CFU/cm² reduction of L. monocytogenes was observed for turkey tenders for all packaging treatments. After 48 h, turkey tenders showed >1 log CFU/cm² reduction of L. monocytogenes for all packaging treatments except for vacuum, where only 0.9 log CFU/cm² reduction was observed. After 72 h, reductions for all packaging treatments for turkey tenders ranged from 1.5 to 2.4 log CFU/cm². For kippered beef steak, there was no interaction between the packaging treatments and all storage times (P > 0.05) whereas, time was different (P packaging treatments and a 2.1 log CFU/ cm² L. monocytogenes reduction at 72 h of storage time. Processors of kippered beef steak and turkey tenders could use a combination of vacuum or nitrogen-flushing or heat sealed with an oxygen scavenger packaging methods and a holding time of 24 h prior to shipping to reduce potential L. monocytogenes numbers by ≥1 log. However, processors should be encouraged to hold packaged product a minimum of 72 h to enhance the margin of safety for L. monocytogenes control. © 2011 Institute of Food Technologists®

  12. CHANGE OF BIOCHEMICAL COMPOSITION OF PUMPKIN FRUITS DEPENDING ON STORAGE TIME

    Directory of Open Access Journals (Sweden)

    A. S. Karapetyan

    2015-01-01

    Full Text Available Pumpkin fruits are the source of carbohydrates, mineral salts and vitamins during wintertime. The change of the biochemical compositions of pumpkin fruits depending on storage time has been studied. The results of chemical analysis revealed that during four months of storage the content of quality indicators increased followed by its reduction after five and more month of storage

  13. [Delayed testing for the diagnosis of fungi in the urines. Evaluation of the BD Vacutainer C&S tubes for the storage of urine samples at room temperature].

    Science.gov (United States)

    Baixench, M T; Al-Sheikh, M; Paugam, A

    2005-01-01

    The study included 37 urine samples which have been artificially infected with low levels (10(3) CFU/mL) of various fungi strains. We compared the effects of sample storage, up to 48 hours, at room temperature, in a urine evacuated tube containing specific additives with storage at + 4 degrees C, for the same length of time, in a urine evacuated tube without any additives. There have been no differences of results (speed of growth and colony size) between the 2 modes of storage. However, the experience has shown that samples needed a careful mixing before seeding to avoid underdetection of the strains. Based on the study results, the BD Vacutainer C&S tubes are suitable for delayed testing for the diagnosis of urine fungal infection.

  14. Urine storage under refrigeration preserves the sample in chemical, cellularity and bacteriuria analysis of ACS

    Directory of Open Access Journals (Sweden)

    Karen Cristina Barcellos Ribeiro

    2013-12-01

    Full Text Available INTRODUCTION: The analysis of urine abnormal constituents and sediment (ACS comprises tests of great diagnostic and prognostic value in clinical practice. When the analysis of ACS cannot be performed within two hours after collection, the sample must be preserved in order to avoid pre-analytical interferences. Refrigeration is the most applied technique due to its cost effectiveness. Moreover, it presents fewer inconveniences when compared to chemical preservation. However, changes in ACS may also occur in samples under refrigeration. OBJECTIVE: To analyze the influence of refrigeration at 2 to 8ºC on the storage of urine samples within 24 hours. MATERIAL AND METHOD: A total of 80 urine samples were selected from patients admitted at Universidade Federal de Juiz de Fora (UFJF university hospital, which were tested for ACS at room temperature and stored under refrigeration for 6, 12 and 24 hours. RESULTS: The results showed that refrigeration proved to be effective when compared to samples kept at room temperature, inasmuch as the physical, chemical, microbial and cellularity features were preserved. Nevertheless, crystalluria was present after a 6- hour storage period. CONCLUSION: The tests revealed that cooling preserved cellularity and chemical characteristics of urine samples for up to 12 hours. Nonetheless, the precipitation of crystals was evident in this storage method. Thus, the possible consequences of storing urine samples for ACS test under these conditions should be included in the analysis report.

  15. Assessment of the influence of different sample processing and cold storage duration on plant free proline content analyses.

    Science.gov (United States)

    Teklić, Tihana; Spoljarević, Marija; Stanisavljević, Aleksandar; Lisjak, Miroslav; Vinković, Tomislav; Parađiković, Nada; Andrić, Luka; Hancock, John T

    2010-01-01

    A method which is widely accepted for the analysis of free proline content in plant tissues is based on the use of 3% sulfosalicylic acid as an extractant, followed by spectrophotometric quantification of a proline-ninhydrin complex in toluene. However, sample preparation and storage may influence the proline actually measured. This may give misleading or difficult to compare data. To evaluate free proline levels fresh and frozen strawberry (Fragaria × ananassa Duch.) leaves and soybean [Glycine max (L.) Merr.] hypocotyl tissues were used. These were ground with or without liquid nitrogen and proline extracted with sulfosalicylic acid. A particular focus was the influence of plant sample cold storage duration (1, 4 and 12 weeks at -20°C) on tissue proline levels measured. The free proline content analyses, carried out in leaves of Fragaria × ananassa Duch. as well as in hypocotyls of Glycine max (L.) Merr., showed a significant influence of the sample preparation method and cold storage period. Long-term storage of up to 12 weeks at -20°C led to a significant increase in the measured proline in all samples analysed. The observed changes in proline content in plant tissue samples stored at -20°C indicate the likelihood of the over-estimation of the proline content if the proline analyses are delayed. Plant sample processing and cold storage duration seem to have an important influence on results of proline analyses. Therefore it is recommended that samples should be ground fresh and analysed immediately. Copyright © 2010 John Wiley & Sons, Ltd.

  16. Physicochemical and microbiological changes during the refrigerated storage of lamb loins sous-vide cooked at different combinations of time and temperature.

    Science.gov (United States)

    Roldán, Mar; Antequera, Teresa; Hernández, Alejandro; Ruiz, Jorge

    2015-10-01

    This study aimed to determine the influence of cooking temperature (either 60 ℃ or 80 ℃) and time (6 h or 24 h) on the physicochemical (weight loss, moisture content, instrumental color, instrumental texture, lipid and protein oxidation) and microbiological changes underwent by sous-vide cooked lamb loins during refrigerated storage for 30 days. There was a slight trend to decreasing weight losses in some of the cooking treatments, but only in samples cooked at 60 ℃ for 6 h it was paralleled with an increase in moisture content. The only noteworthy oxidative change was a marked decrease in conjugated dienes after two weeks of storage in samples cooked at 80 ℃ for 24 h. Neither instrumental texture nor color showed noticeable variations during the storage. Microbial population remained quite low during the whole refrigerated storage. Overall, most of the studied parameters showed only scarce changes throughout 30 days of refrigerated storage that most likely would not influence the quality of sous-vide cooked loin lambs. © The Author(s) 2014.

  17. The impact of COI-based storage on order-picking times

    Directory of Open Access Journals (Sweden)

    Grzegorz Tarczyński

    2017-09-01

    Full Text Available Background: The increasing competitiveness on the global markets enforces the need for a fast and reliable delivery. This task is possible to perform by improving the order-picking systems. The implementation of automated storage and retrieval systems (AS/RS is not always profitable. In the warehouses where the order-picking is performed in accordance with the principle of picker-to-part rule, the picking efficiency optimization includes among others: the warehouse layout, the storage policy, the routing heuristic, the way of zoning, the order-batching method, and the sequencing of pick-lists. In the paper the impact of the storage policy on the order-picking times is checked. Methods: The influence of storage based on Heskett’s cube-per-order index (COI on the average order-picking times is analyzed. The items based on increasing values of COI index are divided on classes. To determine the demand for items the analytical function proposed by Caron is used. Results: In the paper the benefits of storage based on COI index are compared with random storage and storage based only on picking frequency. It is assumed that the bin, to which the picker collects items has limited capacity – some orders has to be divided on smaller pick-lists. The analysis was performed using simulation tools. Additionally, the algorithm (taking into account different sizes of picker’s bin for order-batching is presented. Conclusions: The analysis shows that the COI-based storage is particularly effective when the size of items increases. The COI-based curve is less skewed than the curve based only on picking frequency. The choice of storage policy should be carried out together with routing heuristic. The use of batching algorithm significantly increases the effectiveness of the order-picking process, but the optimal size of picker’s bin (and batch should be optimized with consideration the sorting process.

  18. Importance of storage time in mesophilic anaerobic digestion of food waste.

    Science.gov (United States)

    Lü, Fan; Xu, Xian; Shao, Liming; He, Pinjing

    2016-07-01

    Storage was used as a pretreatment to enhance the methanization performance of mesophilic anaerobic digestion of food waste. Food wastes were separately stored for 0, 1, 2, 3, 4, 5, 7, and 12days, and then fed into a methanogenic reactor for a biochemical methane potential (BMP) test lasting up to 60days. Relative to the methane production of food waste stored for 0-1day (285-308mL/g-added volatile solids (VSadded)), that after 2-4days and after 5-12days of storage increased to 418-530 and 618-696mL/g-VSadded, respectively. The efficiency of hydrolysis and acidification of pre-stored food waste in the methanization reactors increased with storage time. The characteristics of stored waste suggest that methane production was not correlated with the total hydrolysis efficiency of organics in pre-stored food waste but was positively correlated with the storage time and acidification level of the waste. From the results, we recommend 5-7days of storage of food waste in anaerobic digestion treatment plants. Copyright © 2016. Published by Elsevier B.V.

  19. Effect of storage media and time on fin explants culture in the ...

    African Journals Online (AJOL)

    The effect of storage media and time was investigated on fin explants culture in the goldfish (Carassius auratus). Fin explants under sterile conditions were able to produce cells at different storage media and time. On the outgrowth of cells, fin explants stored for seven days before culturing showed significantly higher growth ...

  20. Review of Analytes of Concern and Sample Methods for Closure of DOE High Level Waste Storage Tanks

    International Nuclear Information System (INIS)

    Thomas, T.R.

    2002-01-01

    Sampling residual waste after tank cleaning and analysis for analytes of concern to support closure and cleaning targets of large underground tanks used for storage of legacy high level radioactive waste (HLW) at Department of Energy (DOE) sites has been underway since about 1995. The DOE Tanks Focus Area (TFA) has been working with DOE tank sites to develop new sampling plans, and sampling methods for assessment of residual waste inventories. This paper discusses regulatory analytes of concern, sampling plans, and sampling methods that support closure and cleaning target activities for large storage tanks at the Hanford Site, the Savannah River Site (SRS), the Idaho National Engineering and Environmental Laboratory (INEEL), and the West Valley Demonstration Project (WVDP)

  1. Studying unsaturated epikarst water storage properties by time lapse surface to depth gravity measurements

    Science.gov (United States)

    Deville, S.; Champollion, C.; chery, J.; Doerflinger, E.; Le Moigne, N.; Bayer, R.; Vernant, P.

    2011-12-01

    The assessment of water storage in the unsaturated zone in karstic areas is particularly challenging. Indeed, water flow path and water storage occur in quite heterogeneous ways through small scale porosity, fractures, joints and large voids. Due to this large heterogeneity, it is therefore difficult to estimate the amount of water circulating in the vadose zone by hydrological means. One indirect method consists to measure the gravity variation associated to water storage and withdrawal. Here, we apply a gravimetric method in which the gravity is measured at the surface and at depth on different sites. Then the time variations of the surface to depth (STD) gravity differences are compared for each site. In this study we attempt to evaluate the magnitude of epikarstic water storage variation in various karst settings using a CG5 portable gravimeter. Surface to depth gravity measurements are performed two times a year since 2009 at the surface an inside caves at different depths on three karst aquifers in southern France : 1. A limestone site on the Larzac plateau with a vadose zone thickness of 300m On this site measurements are done on five locations at different depths going from 0 to 50 m; 2. A dolomitic site on the Larzac plateau (Durzon karst aquifer) with a vadose zone thickness of 200m; Measurements are taken at the surface and at 60m depth 3. A limestone site on the Hortus karst aquifer and "Larzac Septentrional karst aquifer") with a vadose zone thickness of only 35m. Measurements are taken at the surface and at 30m depth Therefore, our measurements are used in two ways : First, the STD differences between dry and wet seasons are used to estimate the capacity of differential storage of each aquifer. Surprisingly, the differential storage capacity of all the sites is relatively invariant despite their variable geological of hydrological contexts. Moreover, the STD gravity variations on site 1 show that no water storage variation occurs beneath 10m depth

  2. Stability Comparison of Free and Encapsulated Lactobacilus casei ATCC 393 in Yoghurt for Long Time Storage

    Directory of Open Access Journals (Sweden)

    Oana Lelia POP

    2016-11-01

    Full Text Available An innovative method of L. casei ATCC 393 encapsulation has been reported in the present study using pectin combined with alginate. The aim of this study was to investigate the effect of encapsulation on the survival of L. casei ATCC 393 in yoghurt during long time storage, free or encapsulated in alginate and alginate pectin microspheres, and influence over yoghurt properties, particularly acidification. Over 35 days of storage in yoghurt, the encapsulated probiotic cells proved a higher viability compared with free probiotic cells. An even higher viability and stability was observed for the samples where pectin was used. Pectin acts as prebiotic during encapsulation of L. casei ATCC 393.

  3. Comparison of physiochemical changes in two popular strawberry cultivars grown in Iran (cvs. Kurdistan & Selva during storage time at 4°C

    Directory of Open Access Journals (Sweden)

    Jouki Mohammad

    2012-01-01

    Full Text Available In this study the effect of storage time on some quality parameters of two strawberry cultivars fruits storage at 4°C have been evaluated. Several quality parameters were monitored during the storage period. The samples were analyzed 1, 7, 14 and 21days during storage. Fruits were analyzed about fruit weight, sugar content, chromatic parameters L*, a*, b*, fruit firmness, total titrable acidity, pH, and sensory evaluation. The Kurdistan strawberries retained their weight throughout the experiment as opposed to the Selva strawberries which lost 0.6% of their weight per day because of dehydration. The Selva cultivar was exceptionally firmer than Kurdistan strawberries. Two cultivars were rich in vitamin C and sugar but these values were more in Kurdistan cultivar. As expected, Chroma decreased and over the storage time in two cultivars. The results of this study showed that packaged Kurdistan strawberries could prove suitable for 7 days at 4°C compare with 4 days for selva strawberries.

  4. Evaluation of Vitamin D3 and D2 Stability in Fortified Flat Bread Samples During Dough Fermentation, Baking and Storage.

    Science.gov (United States)

    Tabibian, Mehrnaz; Torbati, Mohammadali; Afshar Mogaddam, Mohammad Reza; Mirlohi, Maryam; Sadeghi, Malihe; Mohtadinia, Javad

    2017-06-01

    Purpose: Vitamin D, a fat-soluble secosteroid, has a significant role in bone metabolism and helps calcium absorption in the body. Since vitamin D concentration is altered in fortified foods and dietary supplements, the actual amount of vitamin D may differ from the label value. Methods: In this study, the concentrations of vitamin D 2 and D 3 of fortified bread sample were analytically determined. For this purpose, dough or homogenized bread sample was saponified using potassium hydroxide solution (30%, w/v) at 80°C, and the saponified analytes were extracted into n -heptane followed by liquid-liquid extraction. Then n -heptane fraction was evaporated to dryness and the sample was reconstituted in methanol. The effect of different parameters was evaluated by one variable at one-time strategy. Results: The analytes concentrations were evaluated in dough fermentation, baking and storage steps. The effect of temperature in dough fermentation and baking was evaluated at the range of 5-30 and 200-250°C, respectively. Also, the fermentation time was studied in the range of 0-120 min. The analytes concentrations were followed for 1 to 5 days after baking. The results indicated that dough fermentation temperature has no significant effect on the concentration of the analytes. On the other hand, when the dough fermentation time and baking temperature are increased, the analytes concentrations are decreased. Also, the storage duration of the spiked bread samples decreased the analytes concentrations after one day. Conclusion: Based on the obtained results, baking the dough at high temperatures lead to decrease in vitamin levels.

  5. Evaluation of a low-cost procedure for sampling, long-term storage, and extraction of RNA from blood for qPCR analyses

    DEFF Research Database (Denmark)

    Mærkedahl, Rasmus Baadsgaard; Frøkiær, Hanne; Lauritzen, Lotte

    2015-01-01

    Abstract Background: In large clinical trials, where RNA cannot be extracted immediately after sampling, preserving RNA in whole blood is a crucial initial step in obtaining robust qPCR data. The current golden standard for RNA preservation is costly and designed for time-consuming column-based RNA....../binding solution over time and between samples stored and extracted by the two systems. Conclusions: The MagMAX system can be used for storage of human blood for up to 4 months and is equivalent to the PAXgene system for RNA extraction. It furthermore, provides a means for significant cost reduction in large...

  6. Data compilation report: Gas and liquid samples from K West Basin fuel storage canisters

    International Nuclear Information System (INIS)

    Trimble, D.J.

    1995-01-01

    Forty-one gas and liquid samples were taken from spent fuel storage canisters in the K West Basin during a March 1995 sampling campaign. (Spent fuel from the N Reactor is stored in sealed canisters at the bottom of the K West Basin.) A description of the sampling process, gamma energy analysis data, and quantitative gas mass spectroscopy data are documented. This documentation does not include data analysis

  7. Comparison of hydroxy naphthoquinone from North Qinglongyi with different storage times

    Science.gov (United States)

    Xin, G. S.; Ji, Y. B.; Wei, C.

    2017-12-01

    Objective: To determine the appropriate solvent for the extraction of hydroxy naphthoquinone, and to establish a method for the determination of the content of hydroxy naphthoquinone in the North Qinglongyi, and compare the changes of the content of hydroxy naphthoquinone in North Qinglongyi with different storage times. Methods: According to the nature of hydroxy naphthoquinone in alkaline solution will be discolored, so this experiment for Juglone as the standard reagent, 5% KOH solution as a developer, and the absorbance was measured by UV-spectrophotometry at the wavelength of 515 nm. The content of hydroxy naphthoquinone in North Qinglongyi was determined by colorimetric method, and the contents of hydroxy naphthoquinone in North Qinglongyi of different storage times were compared. Results: The optimum extraction solvent was ethyl acetate. The recoveries were 97.73%±1.11% and the RSD was 1.14% (n = 6). The contents of hydroxy naphthoquinone in the North Qinglunyi were 0.0141%, 0.0104% and 0.0073%, respectively, for one year, two years and three years. The content of hydroxy naphthoquinone decreased with the storage time prolonged. Conclusion This experimental method was stability, high recovery rate, simple and reliable. According to the results of this experiment, we can see that the storage time of North Qinglunyi should not be too long. Should try to choose this year’s North Qinglunyi for experimental research.

  8. Effect of semen extender and storage temperature on ram sperm motility over time

    Science.gov (United States)

    Storage of ram semen for long period of time depends on a number of factors, including type of extender and storage temperature. A study compared the effect of semen extender and storage temperature on motility of ram semen stored for 72 h. Semen collected via electroejaculator from 5 mature Katahd...

  9. Histopathologic evaluation of postmortem autolytic changes in bluegill (Lepomis macrohirus and crappie (Pomoxis anularis at varied time intervals and storage temperatures

    Directory of Open Access Journals (Sweden)

    Jami George

    2016-04-01

    Full Text Available Information is lacking on preserving fish carcasses to minimize postmortem autolysis artifacts when a necropsy cannot be performed immediately. The purpose of this study was to qualitatively identify and score histologic postmortem changes in two species of freshwater fish (bluegill—Lepomis macrochirus; crappie—Pomoxis annularis, at varied time intervals and storage temperatures, to assess the histologic quality of collected samples. A pooled sample of 36 mix sex individuals of healthy bluegill and crappie were euthanized, stored either at room temperature, refrigerated at 4 °C, or frozen at −20 °C, and then necropsied at 0, 4, 24, and 48 h intervals. Histologic specimens were evaluated by light microscopy. Data showed that immediate harvesting of fresh samples provides the best quality and refrigeration would be the preferred method of storage if sample collection had to be delayed for up to 24 h. When sample collection must be delayed more than 24 h, the preferred method of storage to minimize autolysis artifacts is freezing if evaluation of the gastrointestinal tract is most important, or refrigeration if gill histology is most important. The gill arch, intestinal tract, followed by the liver and kidney were the most sensitive organs to autolysis.

  10. FAME Storage Time in an Optimized Natural Antioxidant Mixture

    Directory of Open Access Journals (Sweden)

    Rodolfo Lopes Coppo

    2013-01-01

    Full Text Available The study of B100 biodiesel oxidation stability, and its conservation, is extremely important to control its quality, especially regarding storage. Many spices have shown antioxidant effect and are the targets of study. Knowing the oxidation process in greater detail allows a reliable storage period to be stipulated for the biodiesel without its degradation until the time of use. Results have shown that according to the accelerated stove method, the optimal mixture, composed of 100% of oregano extract, can confer a 535-day shelf life to biodiesel without evident oxidation. According to the results obtained by the Rancimat method, the ideal mixture consists of 100% rosemary, resulting in 483 days of storage. The application of the process variable showed that the accelerated stove method was more suitable to determine oxidative stability of biodiesel.

  11. Hot sample archiving. Revision 3

    International Nuclear Information System (INIS)

    McVey, C.B.

    1995-01-01

    This Engineering Study revision evaluated the alternatives to provide tank waste characterization analytical samples for a time period as recommended by the Tank Waste Remediation Systems Program. The recommendation of storing 40 ml segment samples for a period of approximately 18 months (6 months past the approval date of the Tank Characterization Report) and then composite the core segment material in 125 ml containers for a period of five years. The study considers storage at 222-S facility. It was determined that the critical storage problem was in the hot cell area. The 40 ml sample container has enough material for approximately 3 times the required amount for a complete laboratory re-analysis. The final result is that 222-S can meet the sample archive storage requirements. During the 100% capture rate the capacity is exceeded in the hot cell area, but quick, inexpensive options are available to meet the requirements

  12. Effects of Storage Time on the Quality of Local Chicken Meat

    African Journals Online (AJOL)

    Addressing factors that affect meat quality ... pH values were measured for each sample followed by storage at -20oC to arrest further changes in meat. .... nutritional value in addition to other physical .... Meat and meat products in human.

  13. Freeze core sampling to validate time-lapse resistivity monitoring of the hyporheic zone.

    Science.gov (United States)

    Toran, Laura; Hughes, Brian; Nyquist, Jonathan; Ryan, Robert

    2013-01-01

    A freeze core sampler was used to characterize hyporheic zone storage during a stream tracer test. The pore water from the frozen core showed tracer lingered in the hyporheic zone after the tracer had returned to background concentration in collocated well samples. These results confirmed evidence of lingering subsurface tracer seen in time-lapse electrical resistivity tomographs. The pore water exhibited brine exclusion (ion concentrations in ice lower than source water) in a sediment matrix, despite the fast freezing time. Although freeze core sampling provided qualitative evidence of lingering tracer, it proved difficult to quantify tracer concentration because the amount of brine exclusion during freezing could not be accurately determined. Nonetheless, the additional evidence for lingering tracer supports using time-lapse resistivity to detect regions of low fluid mobility within the hyporheic zone that can act as chemically reactive zones of importance in stream health. © 2012, The Author(s). GroundWater © 2012, National Ground Water Association.

  14. Reproducibility of NMR Analysis of Urine Samples: Impact of Sample Preparation, Storage Conditions, and Animal Health Status

    OpenAIRE

    Schreier, Christina; Kremer, Werner; Huber, Fritz; Neumann, Sindy; Pagel, Philipp; Lienemann, Kai; Pestel, Sabine

    2013-01-01

    Introduction. Spectroscopic analysis of urine samples from laboratory animals can be used to predict the efficacy and side effects of drugs. This employs methods combining 1H NMR spectroscopy with quantification of biomarkers or with multivariate data analysis. The most critical steps in data evaluation are analytical reproducibility of NMR data (collection, storage, and processing) and the health status of the animals, which may influence urine pH and osmolarity. Methods. We treated rats wit...

  15. Spatial and temporal variation of residence time and storage volume of subsurface water evaluated by multi-tracers approach in mountainous headwater catchments

    Science.gov (United States)

    Tsujimura, Maki; Yano, Shinjiro; Abe, Yutaka; Matsumoto, Takehiro; Yoshizawa, Ayumi; Watanabe, Ysuhito; Ikeda, Koichi

    2015-04-01

    Headwater catchments in mountainous region are the most important recharge area for surface and subsurface waters, additionally time and stock information of the water is principal to understand hydrological processes in the catchments. However, there have been few researches to evaluate variation of residence time and storage volume of subsurface water in time and space at the mountainous headwaters especially with steep slope. We performed an investigation on age dating and estimation of storage volume using simple water budget model in subsurface water with tracing of hydrological flow processes in mountainous catchments underlain by granite, Paleozoic and Tertiary, Yamanashi and Tsukuba, central Japan. We conducted hydrometric measurements and sampling of spring, stream and ground waters in high-flow and low-flow seasons from 2008 through 2012 in the catchments, and CFCs, stable isotopic ratios of oxygen-18 and deuterium, inorganic solute constituent concentrations were determined on all water samples. Residence time of subsurface water ranged from 11 to 60 years in the granite catchments, from 17 to 32 years in the Paleozoic catchments, from 13 to 26 years in the Tertiary catchments, and showed a younger age during the high-flow season, whereas it showed an older age in the low-flow season. Storage volume of subsurface water was estimated to be ranging from 10 ^ 4 to 10 ^ 6 m3 in the granite catchments, from 10 ^ 5 to 10 ^ 7 m3 in the Paleozoic catchments, from 10 ^ 4 to 10 ^ 6 m3 in the Tertiary catchments. In addition, seasonal change of storage volume in the granite catchments was the highest as compared with those of the Paleozoic and the Tertiary catchments. The results suggest that dynamic change of hydrological process seems to cause a larger variation of the residence time and storage volume of subsurface water in time and space in the granite catchments, whereas higher groundwater recharge rate due to frequent fissures or cracks seems to cause larger

  16. L-carnitine is a survival factor for chilled storage of rooster semen for a long time.

    Science.gov (United States)

    Fattah, A; Sharafi, M; Masoudi, R; Shahverdi, A; Esmaeili, V

    2017-02-01

    Rooster sperm is sensitive to cooling, which restricts procedures to store sperms for extended periods of time for artificial insemination of commercial flocks. This study was conducted to evaluate the suitability of adding L-carnitine (LC) to chilled-storage of rooster sperm and its effects on sperm quality parameters and its fertility potential during storage at 5 °C. Pooled semen from roosters were divided into six equal aliquots and diluted with media supplemented with different concentrations of LC (0, 0.5, 1, 2, 4 and 8 mM LC). Diluted semen samples were cooled to 5 °C and stored over 48 h. Motility, viability, membrane functionality, lipid peroxidation and mitochondria activity of the sperm were assessed at 0, 24 and 48 h of storage. Moreover, fertility potential of chilled stored sperm was considered at 24 h of storage. While sperm quality was not affected by LC at the beginning of storage (0 h), supplementation of extender with 1 and 2 mM of LC significantly improved the percentage of sperm motility, viability, membrane integrity and mitochondria activity at 24 h and 48 h compared to other groups. Lipid peroxidation was significantly reduced in sperm samples diluted with 1 and 2 mM LC at 24 h (2.15 ± 0.52 nmol/ml and 2.21 ± 0.52 nmol/ml) and 48 h (3.42 ± 0.49 nmol/ml and 3.38 ± 0.49 nmol/ml) compared to other groups. Furthermore, fertility rates during artificial insemination using sperms cooled for 24 h in the presence of 1 and 2 mM LC were significantly higher (78%) than in the control group (64%). These findings suggest that optimum doses of LC could protect rooster sperm against cool storage-induced functional and structural damages. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Influence of different storage times and temperatures on blood gas and acid-base balance in ovine venous blood.

    Science.gov (United States)

    Hussein, H A; Aamer, A A

    2013-01-01

    The present study was designed to investigate the effects of storage temperature and time on blood gas and acid-base balance of ovine venous blood. Ten clinically healthy sheep were used in this study. A total number of 30 blood samples, were divided into three different groups, and were stored in a refrigerator adjusted to +4 ºC (Group I, n = 10), at RT of about 22-25 ºC (Group II, n = 10) and in an incubator adjusted to 37 ºC (Group III, n = 10) for up to 48 h. Blood samples were analysed for blood gas and acid-base indices at 0, 1, 2, 3, 4, 5, 6, 12, 24 and 48 h of storage. In comparison to the baseline value (0), there were significant decreases of blood pH of samples stored at RT and in the incubator after 1 h (ppO2 values were significantly higher for Group I after 2 h and for Groups II and III after 1 h (preference range and it may be of clinical diagnostic use for up to 6 h.

  18. Sensory stability of whole mango juice: influence of temperature and storage time

    Directory of Open Access Journals (Sweden)

    Anderson do Nascimento Oliveira

    2012-12-01

    Full Text Available This study investigated the degradation kinetics of the sensory attributes of commercial whole mango (cv. Ubá juice and evaluated its sensory acceptability during storage. Samples of the product were stored in a BOD incubator at 25, 35, and 45 ºC under 24 hours light (650 lux for 120 days. Sensory analyses (Quantitative Descriptive Analysis - QDA were conducted with trained panel and consumers. The correlations between sensory and physicochemical characteristics (instrumental color and vitamin C content were also assessed. Flavor, aroma, and color vary with temperature and time of storage. Aroma and flavor were most affected by temperature with values of Q10 and Ea equal to 4.16 and 25.31 kcal.mol-1; and 3.61 and 22.80 kcal.mol-1, respectively. The sensory changes observed by the trained panel are related to the degradation of vitamin C and changes in the color coordinates (L* and ΔE* of mango juice. However, consumers were unable to detect changes in the overall quality of the juices. It was observed that the QDA can be a useful tool to assess shelf-life.

  19. Microbial profiling of cpn60 universal target sequences in artificial mixtures of vaginal bacteria sampled by nylon swabs or self-sampling devices under different storage conditions.

    Science.gov (United States)

    Schellenberg, John J; Oh, Angela Yena; Hill, Janet E

    2017-05-01

    The vaginal microbiome is increasingly characterized by deep sequencing of universal genes. However, there are relatively few studies of how different specimen collection and sample storage and processing influence these molecular profiles. Here, we evaluate molecular microbial community profiles of samples collected using the HerSwab™ self-sampling device, compared to nylon swabs and under different storage conditions. In order to minimize technical variation, mixtures of 11 common vaginal bacteria in simulated vaginal fluid medium were sampled and DNA extracts prepared for massively parallel sequencing of the cpn60 universal target (UT). Three artificial mixtures imitating commonly observed vaginal microbiome profiles were easily distinguished and proportion of sequence reads correlated with the estimated proportion of the organism added to the artificial mixtures. Our results indicate that cpn60 UT amplicon sequencing quantifies the proportional abundance of member organisms in these artificial communities regardless of swab type or storage conditions, although some significant differences were observed between samples that were stored frozen and thawed prior to DNA extraction, compared to extractions from samples stored at room temperature for up to 7days. Our results indicate that an on-the-market device developed for infectious disease diagnostics may be appropriate for vaginal microbiome profiling, an approach that is increasingly facilitated by rapidly dropping deep sequencing costs. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Correction of Sample-Time Error for Time-Interleaved Sampling System Using Cubic Spline Interpolation

    Directory of Open Access Journals (Sweden)

    Qin Guo-jie

    2014-08-01

    Full Text Available Sample-time errors can greatly degrade the dynamic range of a time-interleaved sampling system. In this paper, a novel correction technique employing a cubic spline interpolation is proposed for inter-channel sample-time error compensation. The cubic spline interpolation compensation filter is developed in the form of a finite-impulse response (FIR filter structure. The correction method of the interpolation compensation filter coefficients is deduced. A 4GS/s two-channel, time-interleaved ADC prototype system has been implemented to evaluate the performance of the technique. The experimental results showed that the correction technique is effective to attenuate the spurious spurs and improve the dynamic performance of the system.

  1. The Effect of Storage Time, Temperature and Type of Packaging on the Release of Phthalate Esters into Packed
Acidic Liquids.

    Science.gov (United States)

    Rastkari, Noushin; Zare Jeddi, Maryam; Yunesian, Masud; Ahmadkhaniha, Reza

    2017-12-01

    Acidic liquids such as verjuice, lemon juice and vinegar are frequently consumed in Iran. Different kinds of acidic liquids are packaged in polyethylene terephthalate (PET) and high-density polyethylene (HDPE) bottles. There is evidence indicating that phthalates can leach from PET and HDPE bottles into their contents. In this work the effect of storage time, temperature and bottle type on the migration of phthalates from packaging materials into acidic liquids is studied by analyzing the samples stored under different conditions, before storage and after 2, 4 and 6 months of storage. The determined mean phthalate concentrations in µg/L were: liquids. The possible migration of phthalic acid esters from plastic packaging materials into the contents was indicated by the results of the present study.

  2. Storage time of transfused blood and disease recurrence after colorectal cancer surgery

    DEFF Research Database (Denmark)

    Mynster, T; Nielsen, Hans Jørgen

    2001-01-01

    of the transfused blood. Therefore, we studied the relationship between blood storage time and the development of disease recurrence and long-term survival after colorectal cancer surgery. METHODS: Preoperative and postoperative data were prospectively recorded in 740 patients undergoing elective resection...... for primary colorectal cancer. None of the patients received preoperative or postoperative chemotherapy or radiation therapy. Endpoints were overall survival and disease recurrence in the subgroup of patients operated on with curative intention who also survived the first 30 days after operation. Storage......BACKGROUND: Perioperative blood transfusion and subsequent development of postoperative infectious complications may lead to poor prognosis of patients with colorectal cancer. It has been suggested that the development of postoperative infectious complications may be related to the storage time...

  3. Proteolysis in salmon ( Salmo salar ) during cold storage : Effects of storage time and smoking process

    DEFF Research Database (Denmark)

    Lund, K.E.; Nielsen, Henrik Hauch

    2001-01-01

    Changes in free amino acids (FAAs), small peptides and myofibrillar proteins were investigated in salmon (Salmo salar) muscle stored at OC for up to 23 days and after the stored salmon was smoked. Storage time and smoking process did not increase the formation of FAAs and small peptides indicating...

  4. Genotyping for DQA1 and PM loci in urine using PCR-based amplification: effects of sample volume, storage temperature, preservatives, and aging on DNA extraction and typing.

    Science.gov (United States)

    Vu, N T; Chaturvedi, A K; Canfield, D V

    1999-05-31

    Urine is often the sample of choice for drug screening in aviation/general forensic toxicology and in workplace drug testing. In some instances, the origin of the submitted samples may be challenged because of the medicolegal and socioeconomic consequences of a positive drug test. Methods for individualization of biological samples have reached a new boundary with the application of the polymerase chain reaction (PCR) in DNA profiling, but a successful characterization of the urine specimens depends on the quantity and quality of DNA present in the samples. Therefore, the present study investigated the influence of storage conditions, sample volume, concentration modes, extraction procedures, and chemical preservations on the quantity of DNA recovered, as well as the success rate of PCR-based genotyping for DQA1 and PM loci in urine. Urine specimens from male and female volunteers were divided and stored at various temperatures for up to 30 days. The results suggested that sample purification by dialfiltration, using 3000-100,000 molecular weight cut-off filters, did not enhance DNA recovery and typing rate as compared with simple centrifugation procedures. Extraction of urinary DNA by the organic method and by the resin method gave comparable typing results. Larger sample volume yielded a higher amount of DNA, but the typing rates were not affected for sample volumes between 1 and 5 ml. The quantifiable amounts of DNA present were found to be greater in female (14-200 ng/ml) than in male (4-60 ng/ml) samples and decreased with the elapsed time under both room temperature (RT) and frozen storage. Typing of the male samples also demonstrated that RT storage samples produced significantly higher success rates than that of frozen samples, while there was only marginal difference in the DNA typing rates among the conditions tested using female samples. Successful assignment of DQA1 + PM genotype was achieved for all samples of fresh urine, independent of gender

  5. Factors affecting red blood cell storage age at the time of transfusion.

    Science.gov (United States)

    Dzik, Walter H; Beckman, Neil; Murphy, Michael F; Delaney, Meghan; Flanagan, Peter; Fung, Mark; Germain, Marc; Haspel, Richard L; Lozano, Miguel; Sacher, Ronald; Szczepiorkowski, Zbigniew; Wendel, Silvano

    2013-12-01

    Clinical trials are investigating the potential benefit resulting from a reduced maximum storage interval for red blood cells (RBCs). The key drivers that determine RBC age at the time of issue vary among individual hospitals. Although progressive reduction in the maximum storage period of RBCs would be expected to result in smaller hospital inventories and reduced blood availability, the magnitude of the effect is unknown. Data on current hospital blood inventories were collected from 11 hospitals and three blood centers in five nations. A general predictive model for the age of RBCs at the time of issue was developed based on considerations of demand for RBCs in the hospital. Age of RBCs at issue is sensitive to the following factors: ABO group, storage age at the time of receipt by the hospital, the restock interval, inventory reserve, mean demand, and variation in demand. A simple model, based on hospital demand, may serve as the basis for examining factors affecting the storage age of RBCs in hospital inventories. The model suggests that the age of RBCs at the time of their issue to the patient depends on factors external to the hospital transfusion service. Any substantial change in the expiration date of stored RBCs will need to address the broad variation in demand for RBCs while attempting to balance considerations of availability and blood wastage. © 2013 American Association of Blood Banks.

  6. Identification of sixteen peptides reflecting heat and/or storage induced processes by profiling of commercial milk samples.

    Science.gov (United States)

    Ebner, Jennifer; Baum, Florian; Pischetsrieder, Monika

    2016-09-16

    Peptide profiles of different drinking milk samples were examined to study how the peptide fingerprint of milk reflects processing conditions. The combination of a simple and fast method for peptide extraction using stage tips and MALDI-TOF-MS enabled the fast and easy generation and relative quantification of peptide fingerprints for high-temperature short-time (HTST), extended shelf life (ESL) and ultra-high temperature (UHT) milk of the same dairies. The relative quantity of 16 peptides changed as a function of increasing heat load. Additional heating experiments showed that among those, the intensity of peptide β-casein 196-209 (m/z 1460.9Da) was most heavily influenced by heat treatment indicating a putative marker peptide for milk processing conditions. Storage experiments with HTST- and UHT milk revealed that the differences between different types of milk samples were not only caused by the heating process. Relevant was also the proteolytic activity of enzymes during storage, which were differently influenced by the heat treatment. These results indicate that the peptide profile may be suitable to monitor processing as well as storage conditions of milk. In the present study, peptide profiling of different types of milk was carried out by MALDI-TOF-MS after stage-tip extraction and relative quantification using an internal reference peptide. Although MALDI-TOF-MS covers only part of the peptidome, the method is easy and quick and is, therefore, suited for routine analysis to address several aspects of food authenticity. Using this method, 16 native peptides were detected in milk that could be modulated by different industrial processes. Subsequent heating and storage experiments with pasteurized and UHT milk confirmed that these peptides are indeed related to the production or storage conditions of the respective products. Furthermore, the heating experiments revealed one peptide, namely the β-casein-derived sequence β-casein 196-209, which underwent

  7. Factors affecting genotyping success in giant panda fecal samples

    Directory of Open Access Journals (Sweden)

    Ying Zhu

    2017-05-01

    Full Text Available Fecal samples play an important role in giant panda conservation studies. Optimal preservation conditions and choice of microsatellites for giant panda fecal samples have not been established. In this study, we evaluated the effect of four factors (namely, storage type (ethanol (EtOH, EtOH −20 °C, 2-step storage medium, DMSO/EDTA/Tris/salt buffer (DETs and frozen at −20 °C, storage time (one, three and six months, fragment length, and repeat motif of microsatellite loci on the success rate of microsatellite amplification, allelic dropout (ADO and false allele (FA rates from giant panda fecal samples. Amplification success and ADO rates differed between the storage types. Freezing was inferior to the other four storage methods based on the lowest average amplification success and the highest ADO rates (P < 0.05. The highest microsatellite amplification success was obtained from either EtOH or the 2-step storage medium at three storage time points. Storage time had a negative effect on the average amplification of microsatellites and samples stored in EtOH and the 2-step storage medium were more stable than the other three storage types. We only detected the effect of repeat motif on ADO and FA rates. The lower ADO and FA rates were obtained from tri- and tetra-nucleotide loci. We suggest that freezing should not be used for giant panda fecal preservation in microsatellite studies, and EtOH and the 2-step storage medium should be chosen on priority for long-term storage. We recommend candidate microsatellite loci with longer repeat motif to ensure greater genotyping success for giant panda fecal studies.

  8. Analysis of Dust Samples Collected from an In-Service Interim Storage System at the Maine Yankee Nuclear Site.

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Charles R.; Enos, David

    2016-10-01

    In July, 2016, the Electric Power Research Institute and industry partners performed a field test at the Maine Yankee Nuclear Site, located near Wiscasset, Maine. The primary goal of the field test was to evaluate the use of robots in surveying the surface of an in-service interim storage canister within an overpack; however, as part of the demonstration, dust and soluble salt samples were collected from horizontal surfaces within the interim storage system. The storage system is a vertical system made by NAC International, consisting of a steel-lined concrete overpack containing a 304 stainless steel (SS) welded storage canister. The canister did not contain spent fuel but rather greater-than-class-C waste, which did not generate significant heat, limiting airflow through the storage system. The surfaces that were sampled for deposits included the top of the shield plug, the side of the canister, and a shelf at the bottom of the overpack, just below the level of the pillar on which the canister sits. The samples were sent to Sandia National Laboratories for analysis. This report summarizes the results of those analyses. Because the primary goal of the field test was to evaluate the use of robots in surveying the surface of the canister within the overpack, collection of dust samples was carried out in a qualitative fashion, using paper filters and sponges as the sampling media. The sampling focused mostly on determining the composition of soluble salts present in the dust. It was anticipated that a wet substrate would more effectively extract soluble salts from the surface that was sampled, so both the sponges and the filter paper were wetted prior to being applied to the surface of the metal. Sampling was accomplished by simply pressing the damp substrate against the metal surface for two minutes, and then removing it. It is unlikely that the sampling method quantitatively collected dust or salts from the metal surface; however, both substrates did extract a

  9. Clenbuterol storage stability in the bovine urine and liver samples used for European official control in the azores islands (portugal).

    Science.gov (United States)

    Pinheiro, Isabel; Jesuino, Bruno; Barbosa, Jorge; Ferreira, Humberto; Ramos, Fernando; Matos, José; da Silveira, Maria Irene Noronha

    2009-02-11

    Clenbuterol is a well-known growth promoter, illegally used in farm animals, especially in cattle. Samples collected for the screening of beta(2)-agonist residues in Portuguese Azores Islands must travel through all the nine islands until they reach Azores Central Laboratory. If any suspicious sample is detected, it must be further transported to the National Reference Laboratory in Lisbon for confirmation. As a consequence of these circumstances, samples are submitted to different transport and storage times, as well as different temperature conditions and in some cases successive freezing and thawing cycles. As clenbuterol is the most detected beta(2)-agonist growth promoter in the Portuguese Residue Monitoring Plan, studies were conducted on the stability of this compound in incurred samples (bovine liver and urine) at +4, -20 and -60 degrees C over time. Samples kept at -20 degrees C were also analyzed over time after successive freezing and thawing cycles. The analyses of clenbuterol over time were performed by gas chromatography-mass spectrometry (GC-MS) with selected ion monitoring (SIM). Clenbuterol in incurred urine and liver samples was significantly stable up to 20 weeks at -20 and -60 degrees C and after, at least, six consecutive freezings and thawings. At +4 degrees C, clenbuterol remained stable, at least until 12 weeks in urine and up to 20 weeks in liver.

  10. Effect of storage time and temperature on the rheological and microstructural properties of gluten

    NARCIS (Netherlands)

    Nicolas, Y.; Smit, R.J.M.; van Aalst, H.; Esselink, F.J.; Weegels, P.L.; Agterof, W.G.M.

    2003-01-01

    To investigate the effects of frozen storage on the rheological and microstructural properties of gluten, two model systems were investigated: System A, gluten and water; System B, gluten, water, and NaCl. The storage time was varied from 1 to 16 weeks and the storage temperature was varied from -5

  11. Monitoring storage time and quality attribute of egg based on electronic nose

    International Nuclear Information System (INIS)

    Wang Yongwei; Jun Wang; Bo Zhou; Qiujun Lu

    2009-01-01

    The objective of this study was to investigate the potential of an electronic nose (E-nose) technique for monitoring egg storage time and quality attributes. An electronic nose was used to distinguish eggs under cool and room-temperature storage by means of principal component analysis (PCA), linear discriminant analysis (LDA), BP neural network (BPNN) and the combination of a genetic algorithm and BP neural network (GANN). Results showed that the E-nose could distinguish eggs of different storage time under cool and room-temperature storage by LDA, PCA, BPNN and GANN; better prediction values were obtained by GANN than by BPNN. Relationships were established between the E-nose signal and egg quality indices (Haugh unit and yolk factor) by quadratic polynomial step regression (QPSR). The prediction models for Haugh unit and yolk factor indicated a good prediction performance. The Haugh unit model had a standard error of prediction of 3.74 and correlation coefficient 0.91; the yolk factor model had a 0.02 SEP and 0.93 correlation coefficient between predicted and measured values respectively.

  12. Human urine as test material in 1H NMR-based metabonomics: recommendations for sample preparation and storage.

    Science.gov (United States)

    Lauridsen, Michael; Hansen, Steen H; Jaroszewski, Jerzy W; Cornett, Claus

    2007-02-01

    Metabonomic approaches are believed to have the capability of revolutionizing diagnosis of diseases and assessment of patient conditions after medical interventions. In order to ensure comparability of metabonomic 1H NMR data from different studies, we suggest validated sample preparation guidelines for human urine based on a stability study that evaluates effects of storage time and temperature, freeze-drying, and the presence of preservatives. The results indicated that human urine samples should be stored at or below -25 degrees C, as no changes in the 1H NMR fingerprints have been observed during storage at this temperature for 26 weeks. Formation of acetate, presumably due to microbial contamination, was occasionally observed in samples stored at 4 degrees C without addition of a preservative. Addition of a preserving agent is not mandatory provided that the samples are stored at -25 degrees C. Thus, no differences were observed between 1H NMR spectra of nonpreserved urines and urines with added sodium azide and stored at -25 degrees C, whereas the presence of sodium fluoride caused a shift of especially citrate resonances. Freeze-drying of urine and reconstitution in D2O at pH 7.4 resulted in the disappearance of the creatinine CH2 signal at delta 4.06 due to deuteration. A study evaluating the effects of phosphate buffer concentration on signal variability and assessment of the probability of citrate or creatinine resonances crossing bucket border (a boundary between adjacent integrated regions) led to the conclusion that a minimum buffer concentration of 0.3 M is adequate for normal urines used in this study. However, final buffer concentration of 1 M will be required for very concentrated urines.

  13. Comparison of methods, storage conditions, and time to analysis of serum and urine creatinine measured from microsamples by liquid chromatography mass spectrometery (LC/MS) vs. Jaffe.

    Science.gov (United States)

    Askenazi, David J; Moore, John F; Fineberg, Naomi; Koralkar, Rajesh; Clevenger, Stephanie; Sharer, Jon Daniel

    2014-09-01

    Measurement of serum creatinine (SCr) and urine creatinine (UCr) is regularly used in clinical and research settings. For small animal experiments and for studies in which sample collection is spare (i.e. neonatal cohorts), measuring SCr and UCr using tiny amounts of sample (as low as 10 mcl) would maximize exploration and minimize iatrogenic blood loss. We performed an evaluation in six healthy adults to determine differences between SCr and UCr values in different methodologies and storage environments and time. Study was conducted using 20 mcl of sample. Analyses were done using two-way repeated measures of ANOVA. Scr values showed no significant differences between LC/MS vs. Jaffe. However, the SCr using LC/MS method was lowest when measured immediately compared to other time points (F = 7.2; Psamples measured by LC/MS. UCr measurements by LC/MS vary more over time, mostly due to the sample measured after 1 year; therefore, storage of urine for more than 90 days measured by LC/MS may provide altered results. © 2014 Wiley Periodicals, Inc.

  14. The influence of storage time and temperature on the measurement of serum, plasma and urine osmolality.

    Science.gov (United States)

    Bezuidenhout, Karla; Rensburg, Megan A; Hudson, Careen L; Essack, Younus; Davids, M Razeen

    2016-07-01

    Many clinical laboratories require that specimens for serum and urine osmolality determination be processed within 3 h of sampling or need to arrive at the laboratory on ice. This protocol is based on the World Health Organization report on sample storage and stability, but the recommendation lacks good supporting data. We studied the effect of storage temperature and time on osmolality measurements. Blood and urine samples were obtained from 16 patients and 25 healthy volunteers. Baseline serum, plasma and urine osmolality measurements were performed within 30 min. Measurements were then made at 3, 6, 12, 24 and 36 h on samples stored at 4-8℃ and room temperature. We compared baseline values with subsequent measurements and used difference plots to illustrate changes in osmolality. At 4-8℃, serum and plasma osmolality were stable for up to 36 h. At room temperature, serum and plasma osmolality were very stable for up to 12 h. At 24 and 36 h, changes from baseline osmolality were statistically significant and exceeded the total allowable error of 1.5% but not the reference change value of 4.1%. Urine osmolality was extremely stable at room temperature with a mean change of less than 1 mosmol/kg at 36 h. Serum and plasma samples can be stored at room temperature for up to 36 h before measuring osmolality. Cooling samples to 4-8℃ may be useful when delays in measurement beyond 12 h are anticipated. Urine osmolality is extremely stable for up to 36 h at room temperature. © The Author(s) 2015.

  15. Use of a holder-vacuum tube device to save on-site hands in preparing urine samples for head-space gas-chromatography, and its application to determine the time allowance for sample sealing.

    Science.gov (United States)

    Kawai, Toshio; Sumino, Kimiaki; Ohashi, Fumiko; Ikeda, Masayuki

    2011-01-01

    To facilitate urine sample preparation prior to head-space gas-chromatographic (HS-GC) analysis. Urine samples containing one of the five solvents (acetone, methanol, methyl ethyl ketone, methyl isobutyl ketone and toluene) at the levels of biological exposure limits were aspirated into a vacuum tube via holder, a device commercially available for venous blood collection (the vacuum tube method). The urine sample, 5 ml, was quantitatively transferred to a 20-ml head-space vial prior to HS-GC analysis. The loaded tubes were stored at +4 ℃ in dark for up to 3 d. The vacuum tube method facilitated on-site procedures of urine sample preparation for HS-GC with no significant loss of solvents in the sample and no need of skilled hands, whereas on-site sample preparation time was significantly reduced. Furthermore, no loss of solvents was detected during the 3-d storage, irrespective of hydrophilic (acetone) or lipophilic solvent (toluene). In a pilot application, high performance of the vacuum tube method in sealing a sample in an air-tight space succeeded to confirm that no solvent will be lost when sealing is completed within 5 min after urine voiding, and that the allowance time is as long as 30 min in case of toluene in urine. The use of the holder-vacuum tube device not only saves hands for transfer of the sample to air-tight space, but facilitates sample storage prior to HS-GC analysis.

  16. Stabilization of Neem Oil Biodiesel with Corn Silk Extract during Long-term Storage.

    Science.gov (United States)

    Ali, Rehab Farouk M; El-Anany, Ayman M

    2017-02-01

    The current study aimed to evaluate the antioxidant efficiency of different extracts of corn silk. In addition, the impact of corn silk extract on oxidative stability of neem biodiesel during storage was studied. The highest phenolics, DPPH radical scavenging and reducing power activities were recorded for methanol-water extract. The longest oxidation stability (10 h) was observed for biodiesel samples blended with 1000 ppm of corn silk extract (CSE). At the end of storage period the induction time of biodiesel samples mixed with 1000 ppm of CSE or butylated hydroxytoluene (BHT) were about 6.72 and 5.63 times as high as in biodiesel samples without antioxidants. Biodiesel samples blended with 1000 ppm of CSE had the lowest acidity at the end of storage period. Peroxide value of biodiesel samples containing 1000 ppm of CSE was about 4.28 times as low as in control sample without antioxidants.

  17. The UK Biobank sample handling and storage protocol for the collection, processing and archiving of human blood and urine.

    Science.gov (United States)

    Elliott, Paul; Peakman, Tim C

    2008-04-01

    UK Biobank is a large prospective study in the UK to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. Extensive data and biological samples are being collected from 500,000 participants aged between 40 and 69 years. The biological samples that are collected and how they are processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. The aim of the UK Biobank sample handling and storage protocol is to specify methods for the collection and storage of participant samples that give maximum scientific return within the available budget. Processing or storage methods that, as far as can be predicted, will preclude current or future assays have been avoided. The protocol was developed through a review of the literature on sample handling and processing, wide consultation within the academic community and peer review. Protocol development addressed which samples should be collected, how and when they should be processed and how the processed samples should be stored to ensure their long-term integrity. The recommended protocol was extensively tested in a series of validation studies. UK Biobank collects about 45 ml blood and 9 ml of urine with minimal local processing from each participant using the vacutainer system. A variety of preservatives, anti-coagulants and clot accelerators is used appropriate to the expected end use of the samples. Collection of other material (hair, nails, saliva and faeces) was also considered but rejected for the full cohort. Blood and urine samples from participants are transported overnight by commercial courier to a central laboratory where they are processed and aliquots of urine, plasma, serum, white cells and red cells stored in ultra-low temperature archives. Aliquots of whole blood are also stored for potential future production of immortalized cell lines. A standard panel of haematology assays is

  18. Effects of Storage Temperature, pH and Time on Urinary Albumin ...

    African Journals Online (AJOL)

    Dr Olaleye

    ABSTRACT: The storage of urine samples at 2-8oC and at -20oC for several weeks is a common laboratory practice in research and epidemiological studies to facilitate batch analysis. Despite numerous studies, there is no agreement on how stable albumin is in urine and the best way to store such urine specimen.

  19. SPENT NUCLEAR FUEL (SNF) PROJECT CANISTER STORAGE BUILDING (CSB) MULTI CANISTER OVERPACK (MCO) SAMPLING SYSTEM VALIDATION (OCRWM)

    International Nuclear Information System (INIS)

    BLACK, D.M.; KLEM, M.J.

    2003-01-01

    Approximately 400 Multi-canister overpacks (MCO) containing spent nuclear fuel are to be interim stored at the Canister Storage Building (CSB). Several MCOs (monitored MCOs) are designated to be gas sampled periodically at the CSB sampling/weld station (Bader 2002a). The monitoring program includes pressure, temperature and gas composition measurements of monitored MCOs during their first two years of interim storage at the CSB. The MCO sample cart (CART-001) is used at the sampling/weld station to measure the monitored MCO gas temperature and pressure, obtain gas samples for laboratory analysis and refill the monitored MCO with high purity helium as needed. The sample cart and support equipment were functionally and operationally tested and validated before sampling of the first monitored MCO (H-036). This report documents the results of validation testing using training MCO (TR-003) at the CSB. Another report (Bader 2002b) documents the sample results from gas sampling of the first monitored MCO (H-036). Validation testing of the MCO gas sampling system showed the equipment and procedure as originally constituted will satisfactorily sample the first monitored MCO. Subsequent system and procedural improvements will provide increased flexibility and reliability for future MCO gas sampling. The physical operation of the sampling equipment during testing provided evidence that theoretical correlation factors for extrapolating MCO gas composition from sample results are unnecessarily conservative. Empirically derived correlation factors showed adequate conservatism and support use of the sample system for ongoing monitored MCO sampling

  20. Fermentation and storage of probiotic yoghurt from goat’s milk

    Directory of Open Access Journals (Sweden)

    Rajka Božanić

    2002-04-01

    Full Text Available Cow’s and goat’s milk supplemented with inulin were fermented withABT4 culture. The population growth of Streptococcus thermophilus,Lactobacillus acidophilus and Bifidobacterium ssp. in plain and inulinsupplemented goat’s milk during fermentation was evaluated. The survival of strains during 28 d of storage was followed in comparison with that of cow’s milk. The time required to reach the desired pH of 4.6 during fermentation was 6 h for both types of milk. At that time the proportion of viable cells of Streptococcus thermophilus, Lactobacillus acidophilus and Bifidobacterium ssp. in all fermented samples was comparable 40 : 33 : 27, respectively. During the storage viable count of streptococci and bifidobacteria have not decreased. In supplemented samples viable counts of bifidobacteria were increased and during 28th day of storage were higher for 0.6 logarithms compared to the non supplemented samples. Surviving of lactobacilli was poorer in fermented goat's milk than in fermented cow's milk during storage. The addition of inulin improved the firmness of fermented goat’s and cow’s milks products. Inulin addition partly masked the goat’s flavour of produced yoghurt. During storage the fermented goat's samples were scored better in comparison with cow's samples. Goat’s milk fermented with probiotic bacteria and fortified with inulin complies with the requirements of functional food.

  1. The Effect of Storage Time, Temperature and Type of Packaging on the Release of Phthalate Esters into Packed Acidic Liquids

    Directory of Open Access Journals (Sweden)

    Noushin Rastkari

    2017-01-01

    Full Text Available Acidic liquids such as verjuice, lemon juice and vinegar are frequently consumed in Iran. Different kinds of acidic liquids are packaged in polyethylene terephthalate (PET and high-density polyethylene (HDPE bottles. There is evidence indicating that phthalates can leach from PET and HDPE bottles into their contents. In this work the effect of storage time, temperature and bottle type on the migration of phthalates from packaging materials into acidic liquids is studied by analyzing the samples stored under different conditions, before storage and after 2, 4 and 6 months of storage. The determined mean phthalate concentrations in μg/L were: <0.04 to 0.501 in verjuice, <0.04 to 0.231 in lemon juice and <0.04 to 0.586 in vinegar. The highest concentrations of diethyl phthalate (DEP and diethyl hexyl phthalate (DEHP were found in PET and HDPE bottles, respectively. Results of analyses before and after storage indicate that under some storage conditions, the concentrations of DEP, DEHP and dibutyl phthalate (DBP increased in acidic liquids. The possible migration of phthalic acid esters from plastic packaging materials into the contents was indicated by the results of the present study.

  2. Impact of collection container material and holding times on sample integrity for mercury and methylmercury in water

    Energy Technology Data Exchange (ETDEWEB)

    Riscassi, Ami L [ORNL; Miller, Carrie L [ORNL; Brooks, Scott C [ORNL

    2014-01-01

    Mercury (Hg) and methylmercury (MeHg) concentrations in streamwater can vary on short timescales (hourly or less) during storm flow and on a diel cycle; the frequency and timing of sampling required to accurately characterize these dynamics may be difficult to accomplish manually. Automated sampling can assist in sample collection; however use has been limited for Hg and MeHg analysis due to stability concerns of trace concentrations during extended storage times. We examined the viability of using automated samplers with disposable low-density polyethylene (LDPE) sample bags to collect industrially contaminated streamwater for unfiltered and filtered Hg and MeHg analysis. Specifically we investigated the effect of holding times ranging from hours to days on streamwater collected during baseflow and storm flow. Unfiltered and filtered Hg and MeHg concentrations decreased with increases in time prior to sample processing; holding times of 24 hours or less resulted in concentration changes (mean 11 7% different) similar to variability in duplicates collected manually during analogous field conditions (mean 7 10% different). Comparisons of samples collected with manual and automated techniques throughout a year for a wide range of stream conditions were also found to be similar to differences observed between duplicate grab samples. These results demonstrate automated sampling into LDPE bags with holding times of 24 hours or less can be effectively used to collect streamwater for Hg and MeHg analysis, and encourage the testing of these materials and methods for implementation in other aqueous systems where high-frequency sampling is warranted.

  3. The Genome-Wide DNA Methylation Profile of Peripheral Blood Is Not Systematically Changed by Short-Time Storage at Room Temperature

    Directory of Open Access Journals (Sweden)

    Nicklas Heine Staunstrup

    2017-12-01

    Full Text Available Background: Epigenetic epidemiology has proven an important research discipline in the delineation of diseases of complex etiology. The approach, in such studies, is often to use bio-banked clinical material, however, many such samples were collected for purposes other than epigenetic studies and, thus, potentially not processed and stored appropriately. The Danish National Birth Cohort (DNBC includes more than 100,000 peripheral and umbilical cord blood samples shipped from maternity wards by ordinary mail in EDTA tubes. While this and other similar cohorts hold great promises for DNA methylation studies the potential systematic changes prompted by storage at ambient temperatures have never been assessed on a genome-wide level. Methods and Results: In this study, matched EDTA whole blood samples were stored up to three days at room temperature prior to DNA extraction and methylated DNA immunoprecipitation coupled with deep sequencing (MeDIP-seq. We established that the quality of the MeDIP-seq libraries was high and comparable across samples; and that the methylation profiles did not change systematically during the short-time storage at room temperature. Conclusion: The global DNA methylation profile is stable in whole blood samples stored for up to three days at room temperature in EDTA tubes making genome-wide methylation studies on such material feasible.

  4. Sensory evaluation of orange juice concentrate as affected by irradiation and storage

    International Nuclear Information System (INIS)

    Spoto, M.H.F.; Domarco, R.E.; Walder, J.M.M.; Scarminio, I.S.; Bruns, R.E.

    1997-01-01

    Effects of storage temperature and time on orange juice concentrates were studied for samples irradiated with 2.5, 5.0 and 7.5 kGy doses from a gamma-ray source as well as for untreated samples. Samples were stored at 0, 5 and 25C for periods of 1, 30, 60 and 90 days. ''Quantitative Descriptive Analysis'' was used to measure concentrate juice quality. Samples stored for more than one day lost quality as indicated by increases in ratings for ''bitterness'', ''medicinal'' and ''cooked'' attributes. Storage at 0 and 5C seemed to have lesser effect on ''sweetness'', ''oily'', ''acidic'' and ''medicinal'' characteristic than those evaluated for samples stores at 25C. Effect of radiation dose on flavor and aroma attributes depended on storage temperature and time. In most cases, higher doses resulted in lower ''orange'' and higher ''bitter'', ''medicinal'' and ''cooked'' ratings. These results indicated that 2.5 kGy combined with 0 and 5C of storage conditions, provided a feasible approach for preserving juice concentrate

  5. Direct Observation of Heavy-Tailed Storage Times of Bed Load Tracer Particles Causing Anomalous Superdiffusion

    Science.gov (United States)

    Bradley, D. Nathan

    2017-12-01

    A consensus has formed that the step length distribution of fluvial bed load is thin tailed and that the observed anomalous superdiffusion of bed load tracer particles must arise from heavy-tailed resting times. However, heavy-tailed resting times have never been directly observed in the field over multiple floods. Using 9 years of data from a large bed load tracer experiment, I show that the spatial variance of the tracer plume scales faster than linearly with integrated excess stream power, indicating anomalous superdiffusion. The superdiffusion is caused by a heavy-tailed distribution of observed storage times that is fit with a truncated Pareto distribution with a tail parameter that is predicted by anomalous diffusion theory. The heavy-tailed distribution of storage times causes the tracer virtual velocity to slow over time, indicated by a sublinear increase in the mean displacement that is predicted by the storage time distribution tail parameter.

  6. Prediction of egg freshness during storage using electronic nose.

    Science.gov (United States)

    Yimenu, Samuel M; Kim, J Y; Kim, B S

    2017-10-01

    The aim of the present study was to investigate the potential of a fast gas chromatography (GC) e-nose for freshness discrimination and for prediction of storage time as well as sensory and internal quality changes during storage of hen eggs. All samples were obtained from the same egg production farm and stored at 20 °C for 20 d. Egg sampling was conducted every 0, 3, 6, 9, 12, 16, and 20 d. During each sampling time, 4 egg cartons (each containing 10 eggs) were randomly selected: one carton for Haugh units, one carton for sensory evaluation and 2 cartons for the e-nose experiment. The e-nose study included 2 independent test sets; calibration (35 samples) and validation (28 samples). Every sampling time, 5 replicates were prepared from one egg carton for calibration samples and 4 replicates were prepared from the remaining egg carton for validation samples. Sensors (peaks) were selected prior to multivariate chemometric analysis; qualitative sensors for principal component analysis (PCA) and discriminant factor analysis (DFA) and quantitative sensors for partial least square (PLS) modeling. PCA and DFA confirmed the difference in volatile profiles of egg samples from 7 different storage times accounting for a total variance of 95.7% and 93.71%, respectively. Models for predicting storage time, Haugh units, odor score, and overall acceptability score from e-nose data were developed using calibration samples by PLS regression. The results showed that these quality indices were well predicted from the e- nose signals, with correlation coefficients of R2 = 0.9441, R2 = 0.9511, R2 = 0.9725, and R2 = 0.9530 and with training errors of 0.887, 1.24, 0.626, and 0.629, respectively. As a result of ANOVA, most of the PLS model results were not significantly (P > 0.05) different from the corresponding reference values. These results proved that the fast GC electronic nose has the potential to assess egg freshness and feasibility to predict multiple egg freshness indices

  7. Physiochemical and antioxidant properties of roselle-mango juice blends; effects of packaging material, storage temperature and time

    Science.gov (United States)

    Mgaya-Kilima, Beatrice; Remberg, Siv Fagertun; Chove, Bernard Elias; Wicklund, Trude

    2015-01-01

    A study was conducted to determine the effects of packaging materials, seasonality, storage temperature and time on physiochemical and antioxidant properties of roselle-mango juice blends. Roselle extract (20%, 40%, 60%, and 80%) was mixed with mango juice and stored in glass and plastic bottles at 4°C and 28°C. Total soluble solids, pH, titratable acidity, reducing sugar, color, vitamin C, total monomeric anthocyanins, total phenols, and antioxidant activity (FRAP) were evaluated in freshly prepared juice, and after, 2, 4, and 6 months of storage. The results showed that total soluble solids, reducing sugars, and pH increased with storage times under different storage time, irrespective of packaging materials. The acidity, color, total monomeric anthocyanin, vitamin C, total phenols, and antioxidant activity decreased during storage irrespective of storage temperature and packaging material. Loss of anthocyanins, total phenols, and vitamin C content were higher in blends stored at 28°C than 4°C. PMID:25838888

  8. Retrieval-travel-time model for free-fall-flow-rack automated storage and retrieval system

    Science.gov (United States)

    Metahri, Dhiyaeddine; Hachemi, Khalid

    2018-03-01

    Automated storage and retrieval systems (AS/RSs) are material handling systems that are frequently used in manufacturing and distribution centers. The modelling of the retrieval-travel time of an AS/RS (expected product delivery time) is practically important, because it allows us to evaluate and improve the system throughput. The free-fall-flow-rack AS/RS has emerged as a new technology for drug distribution. This system is a new variation of flow-rack AS/RS that uses an operator or a single machine for storage operations, and uses a combination between the free-fall movement and a transport conveyor for retrieval operations. The main contribution of this paper is to develop an analytical model of the expected retrieval-travel time for the free-fall flow-rack under a dedicated storage assignment policy. The proposed model, which is based on a continuous approach, is compared for accuracy, via simulation, with discrete model. The obtained results show that the maximum deviation between the continuous model and the simulation is less than 5%, which shows the accuracy of our model to estimate the retrieval time. The analytical model is useful to optimise the dimensions of the rack, assess the system throughput, and evaluate different storage policies.

  9. Coherence time of over a second in a telecom-compatible quantum memory storage material

    Science.gov (United States)

    Rančić, Miloš; Hedges, Morgan P.; Ahlefeldt, Rose L.; Sellars, Matthew J.

    2018-01-01

    Quantum memories for light will be essential elements in future long-range quantum communication networks. These memories operate by reversibly mapping the quantum state of light onto the quantum transitions of a material system. For networks, the quantum coherence times of these transitions must be long compared to the network transmission times, approximately 100 ms for a global communication network. Due to a lack of a suitable storage material, a quantum memory that operates in the 1,550 nm optical fibre communication band with a storage time greater than 1 μs has not been demonstrated. Here we describe the spin dynamics of 167Er3+: Y2SiO5 in a high magnetic field and demonstrate that this material has the characteristics for a practical quantum memory in the 1,550 nm communication band. We observe a hyperfine coherence time of 1.3 s. We also demonstrate efficient spin pumping of the entire ensemble into a single hyperfine state, a requirement for broadband spin-wave storage. With an absorption of 70 dB cm-1 at 1,538 nm and Λ transitions enabling spin-wave storage, this material is the first candidate identified for an efficient, broadband quantum memory at telecommunication wavelengths.

  10. The effect of water storage, elapsed time and contaminants on the bond strength and interfacial polymerization of a nanohybrid composite.

    Science.gov (United States)

    Perriard, Jean; Lorente, Maria Cattani; Scherrer, Susanne; Belser, Urs C; Wiskott, H W Anselm

    2009-12-01

    To systematically characterize the effect of time lapse, water storage, and selected contaminants on the bond strength of a nanofilled dental composite. Half-dumbbell-shaped samples were fabricated out of light-polymerizing composite resin. To function as substrates they were aged for 30 days in water. Prior to bonding, the substrates' surfaces were subjected to the following treatments: 1) Removing a 0.2- to 0.4-mm layer using a fluted carbide bur; 2) grit blasting with 50 microm alumina particles; 3) etching with phosphoric acid gel; 4) grit blasting followed by etching; 5) blasting with tribochemical particles followed by silane application; 6) sanding with 400-grit paper, air aging of the adherent half-sample before bonding; 7) surface contamination with saliva; 8) surface contamination with blood. In each group (n = 30), freshly polymerized (except in group 6) adherent half-samples were bonded to the substrate half-samples by a layer of unfilled adhesive resin. Fifteen full dumbbell-shaped specimens were subjected to tensile testing after 1 h and 15 after 7 days water storage. In a positive control group, freshly cured half-samples were bonded shortly after fabrication. The tensile strength was analyzed using Weibull statistics and presented in terms of the material's characteristic strength and shape parameter. Fractographs of the two weakest and strongest samples of each group were produced. The surfaces were searched to locate hackle, wake hackle and the origin of the fracture. Surface roughness and time lapse increased the bond strength of the repaired specimens. All groups in which surface roughness was produced before bonding increased in repair strength. Post-bonding aging improved strength. Fractographs yielded interpretable data whenever larger surfaces of single phase bonding resin were present. 1) Roughening and etching an aged composite's surface prior to applying a coat of unfilled resin and the filled material increases repair bond strength by up

  11. Diagnostic performance of Schistosoma real-time PCR in urine samples from Kenyan children infected with Schistosoma haematobium

    DEFF Research Database (Denmark)

    Vinkeles Melchers, Natalie V. S.; van Dam, Govert J.; Shaproski, David

    2014-01-01

    treatment. METHODOLOGY: Previously collected urine samples (N = 390) from 114 preselected proven parasitological and/or clinical S. haematobium positive Kenyan schoolchildren were analyzed by a Schistosoma internal transcribed spacer-based real-time PCR after 14 years of storage. Pre-treatment day......, respectively. Based on the 'gold standard', PCR showed high sensitivity (>92%) as compared to >31% sensitivity for microscopy, both pre- and post-treatment. CONCLUSIONS/SIGNIFICANCE: Detection and quantification of Schistosoma DNA in urine by real-time PCR was shown to be a powerful and specific diagnostic...

  12. Capacity retention in hydrogen storage alloys

    Science.gov (United States)

    Anani, A.; Visintin, A.; Srinivasan, S.; Appleby, A. J.; Reilly, J. J.; Johnson, J. R.

    1992-01-01

    Results of our examination of the properties of several candidate materials for hydrogen storage electrodes and their relation to the decrease in H-storage capacity upon open-circuit storage over time are reported. In some of the alloy samples examined to date, only about 10 percent of the hydrogen capacity was lost upon storage for 20 days, while in others, this number was as high as 30 percent for the same period of time. This loss in capacity is attributed to two separate mechanisms: (1) hydrogen desorbed from the electrode due to pressure differences between the cell and the electrode sample; and (2) chemical and/or electrochemical degradation of the alloy electrode upon exposure to the cell environment. The former process is a direct consequence of the equilibrium dissociation pressure of the hydride alloy phase and the partial pressure of hydrogen in the hydride phase in equilibrium with that in the electrolyte environment, while the latter is related to the stability of the alloy phase in the cell environment. Comparison of the equilibrium gas-phase dissociation pressures of these alloys indicate that reversible loss of hydrogen capacity is higher in alloys with P(eqm) greater than 1 atm than in those with P(eqm) less than 1 atm.

  13. Field Sampling Plan for the HWMA/RCRA Closure Certification of the TRA-731 Caustic and Acid Storage Tank System - 1997 Notice of Violation Consent Order

    International Nuclear Information System (INIS)

    Evans, S.K.

    2002-01-01

    This Field Sampling Plan for the HWMA/RCRA Closure Certification of the TRA-731 Caustic and Acid Storage Tank System is one of two documents that comprise the Sampling and Analysis Plan for the HWMA/RCRA closure certification of the TRA-731 caustic and acid storage tank system at the Idaho National Engineering and Environmental Laboratory. This plan, which provides information about sampling design, required analyses, and sample collection and handling procedures, is to be used in conjunction with the Quality Assurance Project Plan for the HWMA/RCRA Closure Certification of the TRA-731 Caustic and Acid Storage Tank System

  14. Study on the influence of temperature, storage time and packaging type on di-n-butylphthalate and di(2-ethylhexyl)phthalate release into packed meals.

    Science.gov (United States)

    Cirillo, Teresa; Fasano, Evelina; Esposito, Francesco; Del Prete, Ernesto; Cocchieri, Renata Amodio

    2013-01-01

    Ready-to-eat meals packed in polyethylene terephthalate (PET) and aluminium dishes, supplied to patients in two hospitals in the Campania region (Italy), were studied to evaluate the probable migration of di-n-butylphthalate (DBP) and di(2-ethylhexyl)phthalate (DEHP) from the packaging into the food. The influence of temperature, storage time and type of package on the migration process was considered, analysing the meals according to three time ranges, before the packaging (T(0)) and after 60 min (T(1)) and 120 min (T(2)) from packaging during the storage in thermostatic delivery carts. At T(0) in the meals sampled before packaging in PET dishes, mean levels of DBP and DEHP were 0.023 ± 0.002 µg/g and 0.069 ± 0.041 µg/g, respectively; the DBP level increased 230% and that of DEHP increased 208% by time T(0) versus T(2). In the meals sampled before packaging (T(0)) in aluminium dishes, the mean levels of DBP and DEHP were 0.030 ± 0.001 µg/g and 0.057 ± 0.015 µg/g, respectively. The significant increase in contaminant levels over storage times for meals packed in PET dishes demonstrates that from packages made of plastic materials the migration of phthalic acid esters into foods is possible. In meals packed in PET dishes, the highest DBP and DEHP increases were observed in the T(0) to T(1) range, which represented the time interval over which meals were kept hot, and mainly in the first ones, where the highest temperatures have been recorded.

  15. The effect of sample storage on the performance and reproducibility of the galactomannan EIA test.

    Science.gov (United States)

    Kimpton, George; White, P Lewis; Barnes, Rosemary A

    2014-08-01

    Galactomannan enzyme immune assay (GM EIA) is a nonculture test for detecting invasive aspergillosis (IA) forming a key part of diagnosis and management. Recent reports have questioned the reproducibility of indices after sample storage. To investigate this, 198 serum samples (72 from cases and 126 from controls) and 61 plasma samples (24 from cases and 37 from controls), initially tested between 2010 and 2013, were retested to determine any change in index. Data were also collected on circulatory protein levels for false-positive serum samples. Serum indices significantly declined on retesting (median: initial, 0.50, retest, 0.23; P < 0.0001). This was shown to be diagnosis dependent as the decline was apparent on retesting of control samples (median: initial 0.50, retest 0.12; P < 0.0001), but was not evident with case samples (median: initial, 0.80, retest, 0.80; P = 0.724). Plasma samples showed little change on reanalysis after long-term storage at 4°C. Retesting after freezing showed a decrease in index values for controls (median: initial 0.40, retest 0.26; P = 0.0505), but no significant change in cases. Circulatory proteins showed a correlation between serum albumin concentration and difference in index value on retesting. Overall, this study suggests that a lack of reproducibility in GM EIA positivity is only significant when disease is absent. Retesting after freezing helps to differentiate false-positive GM EIA results and, with consecutive positivity, could help to improve accuracy in predicting disease status. The freezing of samples prior to testing could potentially reduce false-positivity rates and the need to retest. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. Integrity of the Human Faecal Microbiota following Long-Term Sample Storage.

    Directory of Open Access Journals (Sweden)

    Elahe Kia

    Full Text Available In studies of the human microbiome, faecal samples are frequently used as a non-invasive proxy for the study of the intestinal microbiota. To obtain reliable insights, the need for bacterial DNA of high quality and integrity following appropriate faecal sample collection and preservation steps is paramount. In a study of dietary mineral balance in the context of type 2 diabetes (T2D, faecal samples were collected from healthy and T2D individuals throughout a 13-day residential trial. These samples were freeze-dried, then stored mostly at -20°C from the trial date in 2000/2001 until the current research in 2014. Given the relative antiquity of these samples (~14 years, we sought to evaluate DNA quality and comparability to freshly collected human faecal samples. Following the extraction of bacterial DNA, gel electrophoresis indicated that our DNA extracts were more sheared than extracts made from freshly collected faecal samples, but still of sufficiently high molecular weight to support amplicon-based studies. Likewise, spectrophotometric assessment of extracts revealed that they were of high quality and quantity. A subset of bacterial 16S rRNA gene amplicons were sequenced using Illumina MiSeq and compared against publicly available sequence data representing a similar cohort analysed by the American Gut Project (AGP. Notably, our bacterial community profiles were highly consistent with those from the AGP data. Our results suggest that when faecal specimens are stored appropriately, the microbial profiles are preserved and robust to extended storage periods.

  17. [Sampling, storage and transport of biological materials collected from living and deceased subjects for determination of concentration levels of ethyl alcohol and similarly acting substances. A proposal of updating the blood and urine sampling protocol].

    Science.gov (United States)

    Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew

    2007-01-01

    The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.

  18. Effect of liquid nitrogen storage time on the survival and ...

    African Journals Online (AJOL)

    Investigations were undertaken on the effect of liquid nitrogen (LN) storage time on survival and regeneration of somatic embryos of cocoa (Theobroma cacao l.). Somatic embryos from different cocoa genotypes (AMAZ 3-2, AMAZ 10-1, AMAZ 12, SIAL 93, and IMC 14) at 15.45% moisture content were cryopreserved in LN ...

  19. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE AND SHIPMENT OF URINE SAMPLES FOR SELECTED METALS AND PESTICIDES (UA-F-20.1)

    Science.gov (United States)

    The purpose of this SOP is to guide the collection, storage, and shipment of urine samples collected for the NHEXAS Arizona project. This SOP provides a brief description of sample, collection, preservation, storage, shipping, and custody procedures. This procedure was followed ...

  20. Microparticles variability in fresh frozen plasma: preparation protocol and storage time effects.

    Science.gov (United States)

    Kriebardis, Anastasios G; Antonelou, Marianna H; Georgatzakou, Hara T; Tzounakas, Vassilis L; Stamoulis, Konstantinos E; Papassideri, Issidora S

    2016-05-01

    Extracellular vesicles or microparticles exhibiting procoagulant and thrombogenic activity may contribute to the haemostatic potential of fresh frozen plasma. Fresh frozen plasma was prepared from platelet-rich plasma at 20 °C (Group-1 donors) or directly from whole blood at 4 °C (Group-2 donors). Each unit was aseptically divided into three parts, stored frozen for specific periods of time, and analysed by flow cytometry for procoagulant activity immediately after thaw or following post-thaw storage for 24 h at 4 °C. Donors' haematologic, biochemical and life-style profiles as well as circulating microparticles were analysed in parallel. Circulating microparticles exhibited a considerable interdonor but not intergroup variation. Fresh frozen plasma units were enriched in microparticles compared to plasma in vivo. Duration of storage significantly affected platelet- and red cell-derived microparticles. Fresh frozen plasma prepared directly from whole blood contained more residual platelets and more platelet-derived microparticles compared to fresh frozen plasma prepared from platelet-rich plasma. Consequently, there was a statistically significant difference in total, platelet- and red cell-derived microparticles between the two preparation protocols over storage time in the freezer. Preservation of the thawed units for 24 h at 4 °C did not significantly alter microparticle accumulation. Microparticle accumulation and anti-oxidant capacity of fresh frozen plasma was positively or negatively correlated, respectively, with the level of circulating microparticles in individual donors. The preparation protocol and the duration of storage in the freezer, independently and in combination, influenced the accumulation of microparticles in fresh frozen plasma units. In contrast, storage of thawed units for 24 h at 4 °C had no significant effect on the concentration of microparticles.

  1. Effect of storage time on the characteristics of corn and efficiency of its utilization in broiler chickens

    Directory of Open Access Journals (Sweden)

    Dafei Yin

    2017-09-01

    Full Text Available Corn is one of the staple food and feed ingredients in China, therefore its storage is of particular importance. Corn is typically stored for 2 or more years in national barns before it is sold as a food or feed ingredient. However, the effects of stored corn in national barns on the animal performance and nutrient utilization have not been investigated thus far. This study attempted to determine the effects of storage time on the chemical and physical characteristics of corn and its nutritional value, broiler growth performance, and meat quality. Corn grains used in the present study were stored for 4 different periods, from 2 to 5 yr, under the same conditions in a building at the Beijing National Grain Storage Facility. A total of 240 birds in Exp. 1 and 90 birds in Exp. 2 were used to compare the effects of storage time on the utilization of nutrients of corn, the performance, and meat quality of broilers. The content of starch, crude protein, amino acids, fatty acids, and test weight generally decreased with increasing storage time. Corn stored for over 4 yr showed decreased catalase (CAT and peroxidase (POD activities and increased fat acidity. Body weight gain (BWG and European production index (EPI of broilers from 0 to 3 wk tended to decrease linearly with storage time (0.05  0.05. The digestibility of histidine and arginine, and C18:2 and C18:3 changed quadratically with storage time (P < 0.05. Collectively, the results suggest that the use of corn stored for 4 yr in animal feed decreased the performance and meat quality of broilers. Fat acidity, CAT, and POD activities can be used as indexes for evaluating the storage quality of corn.

  2. Effects of storage methods on time-related changes of titanium surface properties and cellular response

    International Nuclear Information System (INIS)

    Lu Haibin; Zhou Lei; Wan Lei; Li Shaobing; Rong Mingdeng; Guo Zehong

    2012-01-01

    Titanium implants are sold in the market as storable medical devices. All the implants have a certain shelf life during which they maintain their sterility, but variations of the surface properties through this duration have not been subject to a comprehensive assessment. The aim of this study was to investigate the effects of storage methods on time-related changes of titanium surface properties. Acid-etched titanium discs (Sa = 0.82 µm) were placed in a sealed container (tradition method) or submerged in the ddH 2 O/NaCl solution (0.15 mol L −1 )/CaCl 2 solution (0.15 mol L −1 ), and new titanium discs were used as a control group. SEM and optical profiler showed that surface morphology and roughness did not change within different groups, but the XPS analysis confirmed that the surface chemistry altered by different storage protocols as the storage duration increased, and the contact angle also varied with storage methods. The storage method also affected the protein adsorption capacity and cellular response on the titanium surface. All titanium discs stored in the solution maintained their excellent bioactivity even after four weeks storage time, but titanium discs stored in a traditional manner decreased substantially in an age-dependent manner. Much effort is needed to improve the storage methods in order to maintain the bioactivity of a titanium dental implant. (paper)

  3. Gamma irradiation effect and time of storage on the beta-carotene rate of dehydrated parsley

    International Nuclear Information System (INIS)

    Sebastiao, K.I.; Romanelli, M.F.; Leite, Q.R.; Koseki, P.M.; Hamasaki, K.; Villavicencio, A.L.C.H.; Almeida-Muradian, L.B.

    2000-01-01

    The A vitamin is an essential nutrient for men. Therefore, this vitamin or one of its precursors must be ingested for a healthful diet. The carotenoids are also called pro-vitamin A. As any another carotenoid, the β-carotene has a structure with many unsaturations, conferring certain instability. It can be modified and even destroyed for acid, light, heat, oxygen; the formation of cis-trans isomers, reduction of its color and its pro-vitacimin A activity reduction can happen. Those alterations can occur during the processing or storage of the food. The use of the ionizing radiation is a kind of food processing that consists of the use of the high energy of the gamma ray or accelerates electrons, capable to ionize molecules. The carotenoids are considered by literature little sensible to the irradiation. It is suggested doses of 1 to 10 kGy in the irradiation of spices, dehydrated condiments and vegetables. These doses are enough to eliminate or to reduce pathogenic microorganisms and insects, to magnify the time of useful life and still substitute the use of chemical fumigants. They also reveal adequate to the organoleptic aspect, not affecting its flavor and smell. This study had as objective to search the different β-carotene levels in samples of dehydrated parsley submitted to the radiation of 60 Co and stored by 6 months. The results gotten in first analysis had not indicated difference significant statistics in β-carotene rate between the controlled sample and the radiated one. After 6 months of storage, were verified that the β-carotene rate had fallen for the half in both samples

  4. Soil sampling and analysis plan for the 3718-F Alkali Metal Treatment and Storage Facility closure activities

    Energy Technology Data Exchange (ETDEWEB)

    Sonnichsen, J.C.

    1997-05-01

    Amendment V.13.B.b to the approved closure plan (DOE-RL 1995a) requires that a soil sampling and analysis plan be prepared and submitted to the Washington State Department of Ecology (Ecology) for review and approval. Amendment V.13.B.c requires that a diagram of the 3718-F Alkali Metal Treatment and Storage Facility unit (the treatment, storage, and disposal [TSD] unit) boundary that is to be closed, including the maximum extent of operation, be prepared and submitted as part is of the soil sampling and analysis plan. This document describes the sampling and analysis that is to be performed in response to these requirements and amends the closure plan. Specifically, this document supersedes Section 6.2, lines 43--46, and Section 7.3.6 of the closure plan. Results from the analysis will be compared to cleanup levels identified in the closure plan. These cleanup levels will be established using residential exposure assumptions in accordance with the Model Toxics Control Act (MTCA) Cleanup Regulation (Washington Administrative Code [WAC] 173-340) as required in Amendment V.13.B.I. Results of all sampling, including the raw analytical data, a summary of analytical results, a data validation package, and a narrative summary with conclusions will be provided to Ecology as specified in Amendment V.13.B.e. The results and process used to collect and analyze the soil samples will be certified by a licensed professional engineer. These results and a certificate of closure for the balance of the TSD unit, as outlined in Chapter 7.0 of the approved closure plan (storage shed, concrete pad, burn building, scrubber, and reaction tanks), will provide the basis for a closure determination.

  5. Soil sampling and analysis plan for the 3718-F Alkali Metal Treatment and Storage Facility closure activities

    International Nuclear Information System (INIS)

    Sonnichsen, J.C.

    1997-01-01

    Amendment V.13.B.b to the approved closure plan (DOE-RL 1995a) requires that a soil sampling and analysis plan be prepared and submitted to the Washington State Department of Ecology (Ecology) for review and approval. Amendment V.13.B.c requires that a diagram of the 3718-F Alkali Metal Treatment and Storage Facility unit (the treatment, storage, and disposal [TSD] unit) boundary that is to be closed, including the maximum extent of operation, be prepared and submitted as part is of the soil sampling and analysis plan. This document describes the sampling and analysis that is to be performed in response to these requirements and amends the closure plan. Specifically, this document supersedes Section 6.2, lines 43--46, and Section 7.3.6 of the closure plan. Results from the analysis will be compared to cleanup levels identified in the closure plan. These cleanup levels will be established using residential exposure assumptions in accordance with the Model Toxics Control Act (MTCA) Cleanup Regulation (Washington Administrative Code [WAC] 173-340) as required in Amendment V.13.B.I. Results of all sampling, including the raw analytical data, a summary of analytical results, a data validation package, and a narrative summary with conclusions will be provided to Ecology as specified in Amendment V.13.B.e. The results and process used to collect and analyze the soil samples will be certified by a licensed professional engineer. These results and a certificate of closure for the balance of the TSD unit, as outlined in Chapter 7.0 of the approved closure plan (storage shed, concrete pad, burn building, scrubber, and reaction tanks), will provide the basis for a closure determination

  6. Geological storage of CO2 : time frames, monitoring and verification

    International Nuclear Information System (INIS)

    Chalaturnyk, R.; Gunter, W.D.

    2005-01-01

    In order to ensure that carbon dioxide (CO 2 ) injection and storage occurs in an environmentally sound and safe manner, many organizations pursuing the development of a CO 2 geological storage industry are initiating monitoring programs that include operational monitoring; verification monitoring; and environmental monitoring. Each represents an increase in the level of technology used and the intensity and duration of monitoring. For each potential site, the project conditions must be defined, the mechanisms that control the fluid flow must be predicted and technical questions must be addressed. This paper reviewed some of the relevant issues in establishing a monitoring framework for geological storage and defined terms that indicate the fate of injected CO 2 . Migration refers to movement of fluids within the injection formation, while leakage refers to movement of fluids outside the injection formation, and seepage refers to movement of fluids from the geosphere to the biosphere. Currently, regulatory agencies focus mostly on the time period approved for waste fluid injection, including CO 2 , into depleted hydrocarbon reservoirs or deep saline aquifers, which is in the order of 25 years. The lifetime of the injection operation is limited by reservoir capacity and the injection rate. Monitoring periods can be divided into periods based on risk during injection-operation (10 to 25 years), at the beginning of the storage period during pressure equilibration (up to 100 years), and over the long-term (from 100 to 1000 years). The 42 commercial acid gas injection projects currently in operation in western Canada can be used to validate the technology for the short term, while validation of long-term storage can be based on natural geological analogues. It was concluded that a monitored decision framework recognizes uncertainties in the geological storage system and allows design decisions to be made with the knowledge that planned long-term observations and their

  7. Storage time of transfused blood and disease recurrence after colorectal cancer surgery

    DEFF Research Database (Denmark)

    Mynster, T; Nielsen, Hans Jørgen

    2001-01-01

    of the transfused blood. Therefore, we studied the relationship between blood storage time and the development of disease recurrence and long-term survival after colorectal cancer surgery. METHODS: Preoperative and postoperative data were prospectively recorded in 740 patients undergoing elective resection......BACKGROUND: Perioperative blood transfusion and subsequent development of postoperative infectious complications may lead to poor prognosis of patients with colorectal cancer. It has been suggested that the development of postoperative infectious complications may be related to the storage time...... transfused patients (P = 0.004). The survival of patients receiving blood exclusively stored blood stored > or = 21 days, survival was 3.7 years (P = 0.12). Among patients with curative resection (n = 532), the hazard ratio of disease recurrence was 1.5 (95...

  8. Modelling methane emission mitigation by anaerobic digestion: effect of storage conditions and co-digestion.

    Science.gov (United States)

    Moset, Veronica; Wahid, R; Ward, A; Møller, H B

    2018-03-13

    In this work the methane conversion factor (MCF) of untreated and anaerobically digested cattle manure (CM) as a function of storage temperature, time and co-digestion was measured in an in vitro experiment and modelled based on IPCC (2006) methodology (Tier 2). For this, one sample of untreated CM, one sample of mono-digested CM and three samples of CM co-digested with grass were incubated at seven different temperatures (from 5°C to 50°C) over 346 days. The main results showed that ultimate methane yield (B 0 ) of CM is higher than the B 0 reported by the IPCC (2006). Two temperature ranges should be considered for MCF evolution, below 15°C very low MCF was measured in this work for untreated CM, mono and co-digested samples. At higher temperatures, MCF obtained in this work and that provided by the IPCC could be comparable depending on storage time. Anaerobic mono-digestion decreased MCF compared to untreated CM at all temperatures and times, except in the temperature range between 20°C and 25°C if storage time is low, due to a lag phase observed in CM. This lag phase would probably not happen in real storage conditions depending on the proportion of old manure remaining in the storage tank. Co-digestion with grass-decreased MCF compared to mono-digestion, but increased CH 4 production in terms of fresh matter due to the higher B 0 of the mixture. Storage time, temperature and co-digestion should be considered in the quantification of CH 4 emission from digested material.

  9. Low-sampling-rate ultra-wideband digital receiver using equivalent-time sampling

    KAUST Repository

    Ballal, Tarig

    2014-09-01

    In this paper, we propose an all-digital scheme for ultra-wideband symbol detection. In the proposed scheme, the received symbols are sampled many times below the Nyquist rate. It is shown that when the number of symbol repetitions, P, is co-prime with the symbol duration given in Nyquist samples, the receiver can sample the received data P times below the Nyquist rate, without loss of fidelity. The proposed scheme is applied to perform channel estimation and binary pulse position modulation (BPPM) detection. Results are presented for two receivers operating at two different sampling rates that are 10 and 20 times below the Nyquist rate. The feasibility of the proposed scheme is demonstrated in different scenarios, with reasonable bit error rates obtained in most of the cases.

  10. Low-sampling-rate ultra-wideband digital receiver using equivalent-time sampling

    KAUST Repository

    Ballal, Tarig; Al-Naffouri, Tareq Y.

    2014-01-01

    In this paper, we propose an all-digital scheme for ultra-wideband symbol detection. In the proposed scheme, the received symbols are sampled many times below the Nyquist rate. It is shown that when the number of symbol repetitions, P, is co-prime with the symbol duration given in Nyquist samples, the receiver can sample the received data P times below the Nyquist rate, without loss of fidelity. The proposed scheme is applied to perform channel estimation and binary pulse position modulation (BPPM) detection. Results are presented for two receivers operating at two different sampling rates that are 10 and 20 times below the Nyquist rate. The feasibility of the proposed scheme is demonstrated in different scenarios, with reasonable bit error rates obtained in most of the cases.

  11. High density FTA plates serve as efficient long-term sample storage for HLA genotyping.

    Science.gov (United States)

    Lange, V; Arndt, K; Schwarzelt, C; Boehme, I; Giani, A S; Schmidt, A H; Ehninger, G; Wassmuth, R

    2014-02-01

    Storage of dried blood spots (DBS) on high-density FTA(®) plates could constitute an appealing alternative to frozen storage. However, it remains controversial whether DBS are suitable for high-resolution sequencing of human leukocyte antigen (HLA) alleles. Therefore, we extracted DNA from DBS that had been stored for up to 4 years, using six different methods. We identified those extraction methods that recovered sufficient high-quality DNA for reliable high-resolution HLA sequencing. Further, we confirmed that frozen whole blood samples that had been stored for several years can be transferred to filter paper without compromising HLA genotyping upon extraction. Concluding, DNA derived from high-density FTA(®) plates is suitable for high-resolution HLA sequencing, provided that appropriate extraction protocols are employed. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Impact of urine preservation methods and duration of storage on measured levels of environmental contaminants.

    Science.gov (United States)

    Hoppin, Jane A; Ulmer, Ross; Calafat, Antonia M; Barr, Dana B; Baker, Susan V; Meltzer, Helle M; Rønningen, Kjersti S

    2006-01-01

    Collection of urine samples in human studies involves choices regarding shipping, sample preservation, and storage that may ultimately influence future analysis. As more studies collect and archive urine samples to evaluate environmental exposures in the future, we were interested in assessing the impact of urine preservative, storage temperature, and time since collection on nonpersistent contaminants in urine samples. In spiked urine samples stored in three types of urine vacutainers (no preservative, boric acid, and chlorhexidine), we measured five groups of contaminants to assess the levels of these analytes at five time points (0, 24, 48, and 72 h, and 1 week) and at two temperatures (room temperature and 4 degrees C). The target chemicals were bisphenol A (BPA), metabolites of organophosphate (OP), carbamate, and pyrethroid insecticides, chlorinated phenols, and phthalate monoesters, and were measured using five different mass spectrometry-based methods. Three samples were analyzed at each time point, with the exception of BPA. Repeated measures analysis of variance was used to evaluate effects of storage time, temperature, and preservative. Stability was summarized with percent change in mean concentration from time 0. In general, most analytes were stable under all conditions with changes in mean concentration over time, temperature, and preservative being generally less than 20%, with the exception of the OP metabolites in the presence of boric acid. The effect of storage temperature was less important than time since collection. The precision of the laboratory measurements was high allowing us to observe small differences, which may not be important when categorizing individuals into broader exposure groups.

  13. Heavy metal content of tinned soup as a function of storage time

    Energy Technology Data Exchange (ETDEWEB)

    Stelte, W.

    1983-01-01

    Samples were taken from soups prior to their preservation in tins. None of the samples showed an increased content of the investigated heavy metals lead and mercury exceeding the amounts normally found in food. Thus it may be considered as certain that the heavy metal content of soups is not adversely affected by technical processes during their preparation. Increase in heavy metal content by metallic residues from tin manufacture is slight and mainly due to tin, whose content is on average increased in the soup by 0.4 mg/kg. For lead the influence is smaller and for mercury it is not significantly demonstrable. The metallic residues from tin manufacture are an irrelevant quantity in terms of nutrition physiology. Within the investigated 4-year storage-period the lead content shows a tendency to increase towards saturation. Cadmium remains essentially constant, the content of mercury has a downward tendency and reaches zero after 2 to 4 years. Consumers' exposure is in a range known for the consumption of other foodstuffs as well. The use of varnished tins to package industrial soups involves no exposure of consumers to heavy metals justifying any apprehension even after prolonged storage.

  14. CD3-positive B cells: a storage-dependent phenomenon.

    Directory of Open Access Journals (Sweden)

    Angela Nagel

    Full Text Available The majority of clinical studies requires extensive management of human specimen including e.g. overnight shipping of blood samples in order to convey the samples in a central laboratory or to simultaneously analyze large numbers of patients. Storage of blood samples for periods of time before in vitro/ex vivo testing is known to influence the antigen expression on the surface of lymphocytes. In this context, the present results show for the first time that the T cell antigen CD3 can be substantially detected on the surface of human B cells after ex vivo storage and that the degree of this phenomenon critically depends on temperature and duration after blood withdrawal. The appearance of CD3 on the B cell surface seems to be a result of contact-dependent antigen exchange between T and B lymphocytes and is not attributed to endogenous production by B cells. Since cellular subsets are often classified by phenotypic analyses, our results indicate that ex vivo cellular classification in peripheral blood might result in misleading interpretations. Therefore, in order to obtain results reflecting the in vivo situation, it is suggested to minimize times of ex vivo blood storage after isolation of PBMC. Moreover, to enable reproducibility of results between different research groups and multicenter studies, we would emphasize the necessity to specify and standardize the storage conditions, which might be the basis of particular findings.

  15. Factors affecting genotyping success in giant panda fecal samples.

    Science.gov (United States)

    Zhu, Ying; Liu, Hong-Yi; Yang, Hai-Qiong; Li, Yu-Dong; Zhang, He-Min

    2017-01-01

    Fecal samples play an important role in giant panda conservation studies. Optimal preservation conditions and choice of microsatellites for giant panda fecal samples have not been established. In this study, we evaluated the effect of four factors (namely, storage type (ethanol (EtOH), EtOH -20 °C, 2-step storage medium, DMSO/EDTA/Tris/salt buffer (DETs) and frozen at -20 °C), storage time (one, three and six months), fragment length, and repeat motif of microsatellite loci) on the success rate of microsatellite amplification, allelic dropout (ADO) and false allele (FA) rates from giant panda fecal samples. Amplification success and ADO rates differed between the storage types. Freezing was inferior to the other four storage methods based on the lowest average amplification success and the highest ADO rates ( P panda fecal preservation in microsatellite studies, and EtOH and the 2-step storage medium should be chosen on priority for long-term storage. We recommend candidate microsatellite loci with longer repeat motif to ensure greater genotyping success for giant panda fecal studies.

  16. Detecting chaos in irregularly sampled time series.

    Science.gov (United States)

    Kulp, C W

    2013-09-01

    Recently, Wiebe and Virgin [Chaos 22, 013136 (2012)] developed an algorithm which detects chaos by analyzing a time series' power spectrum which is computed using the Discrete Fourier Transform (DFT). Their algorithm, like other time series characterization algorithms, requires that the time series be regularly sampled. Real-world data, however, are often irregularly sampled, thus, making the detection of chaotic behavior difficult or impossible with those methods. In this paper, a characterization algorithm is presented, which effectively detects chaos in irregularly sampled time series. The work presented here is a modification of Wiebe and Virgin's algorithm and uses the Lomb-Scargle Periodogram (LSP) to compute a series' power spectrum instead of the DFT. The DFT is not appropriate for irregularly sampled time series. However, the LSP is capable of computing the frequency content of irregularly sampled data. Furthermore, a new method of analyzing the power spectrum is developed, which can be useful for differentiating between chaotic and non-chaotic behavior. The new characterization algorithm is successfully applied to irregularly sampled data generated by a model as well as data consisting of observations of variable stars.

  17. Detection of methaemoglobinaemia and its application in 'poppers' abuse: maintaining the right balance between reduction and autooxidation during storage.

    Science.gov (United States)

    Domingo, Olwen; Stöver, Andreas; Roider, Gabriele; Graw, Matthias

    2017-03-01

    In our study, we analysed the effect of a variety of storage conditions on the methaemoglobin (MetHb) content of blood samples obtained from altogether 110 deceased subjects with diverse causes of death, including three 'poppers'-related fatalities. The obtained results were compared to data from blood samples of six living, healthy subjects. Results obtained from the spectrophotometric measurement of blood MetHb content suggest that storage at room temperature (RT) and storage at -20 °C result in either highly fluctuating values, as was the case for the RT samples, or values much higher than the initial MetHb concentrations when stored at -20 °C. Blood samples at 4 °C showed more stable MetHb levels, which, however, increased with up to 4 % of the initial value after only 3 weeks of storage. These factors pose a problem in forensic toxicology, especially in nitrite abuse cases, where the involvement of such substance abuse is often unknown at the time of blood sampling and thus often requires longer storage times. Nevertheless, even after the storage of blood samples over several months at 4 and -20 °C, 'poppers' cases still show a significantly higher MetHb concentration as compared to non-'poppers' samples that were stored for the same time period under identical conditions.

  18. Preservation of Biological Activity of Plasma and Platelet-Derived Eye Drops After Their Different Time and Temperature Conditions of Storage.

    Science.gov (United States)

    Anitua, Eduardo; de la Fuente, María; Riestra, Ana; Merayo-Lloves, Jesús; Muruzábal, Francisco; Orive, Gorka

    2015-09-01

    To analyze whether plasma rich in growth factors (PRGF) eye drops preserve their biological characteristics and activity after storage for 3 and 6 months at -20°C, at 4°C, and at room temperature for 72 hours, compared with fresh samples (t0). Blood from 6 healthy donors was harvested and centrifuged to obtain PRGF free of leukocytes. Resulting PRGF eye drops were stored for 3 and 6 months at -20°C. At each time, 2 aliquots were maintained at room temperature or at 4°C for 72 hours. Platelet-derived growth factor-AB, transforming growth factor-β1, vascular endothelial growth factor, epidermal growth factor, insulin-like growth factor-1, angiopoietin-1, and thrombospondin-1 were quantified at each time and temperature of storage. Also, the effect of PRGF eye drops on proliferation of primary human keratocytes was evaluated. All the analyzed growth factor levels remained constant at each time and storage condition. No differences were observed in the proliferative activity of keratocytes after treatment with PRGF eye drops at any studied time or temperature. Finally, there was no microbial contamination in any of the PRGF eye drops. The preservation of the PRGF eye drops at -20°C for up to 3 and 6 months does not mean reduction of the main growth factors and proteins implicated in ocular surface wound healing. Eye drop characteristics and in vitro biological activity were not affected by their usage and conservation for 72 hours at 4°C or at room temperature.

  19. Storage Policies and Optimal Shape of a Storage System

    NARCIS (Netherlands)

    Zaerpour, N.; De Koster, René; Yu, Yugang

    2013-01-01

    The response time of a storage system is mainly influenced by its shape (configuration), the storage assignment and retrieval policies, and the location of the input/output (I/O) points. In this paper, we show that the optimal shape of a storage system, which minimises the response time for single

  20. Effects of fat content, pasteurization method, homogenization pressure, and storage time on the mechanical and sensory properties of bovine milk.

    Science.gov (United States)

    Li, Y; Joyner, H S; Carter, B G; Drake, M A

    2018-04-01

    Fluid milk may be pasteurized by high-temperature short-time pasteurization (HTST) or ultrapasteurization (UP). Literature suggests that UP increases milk astringency, but definitive studies have not demonstrated this effect. Thus, the objective of this study was to determine the effects of pasteurization method, fat content, homogenization pressure, and storage time on milk sensory and mechanical behaviors. Raw skim (fat), 2%, and 5% fat milk was pasteurized in duplicate by indirect UP (140°C, 2.3 s) or by HTST pasteurization (78°C, 15 s), homogenized at 20.7 MPa, and stored at 4°C for 8 wk. Additionally, 2% fat milk was processed by indirect UP and homogenized at 13.8, 20.7, and 27.6 MPa and stored at 4°C for 8 wk. Sensory profiling, instrumental viscosity, and friction profiles of all milk were evaluated at 25°C after storage times of 1, 4, and 8 wk. Sodium dodecyl sulfate PAGE and confocal laser scanning microscopy were used to determine protein structural changes in milk at these time points. Fresh HTST milk was processed at wk 7 for wk 8 evaluations. Ultrapasteurization increased milk sensory and instrumental viscosity compared with HTST pasteurization. Increased fat content increased sensory and instrumental viscosity, and decreased astringency and friction profiles. Astringency, mixed regimen friction profiles, and sensory viscosity also increased for UP versus HTST. Increased storage time showed no effect on sensory viscosity or mechanical viscosity. However, increased storage time generally resulted in increased friction profiles and astringency. Sodium dodecyl sulfate PAGE and confocal laser scanning microscopy showed increased denatured whey protein in UP milk compared with HTST milk. The aggregates or network formed by these proteins and casein micelles likely caused the increase in viscosity and friction profiles during storage. Homogenization pressure did not significantly affect friction behaviors, mechanical viscosity, or astringency; however

  1. Calibrated photostimulated luminescence is an effective approach to identify irradiated orange during storage

    Science.gov (United States)

    Jo, Yunhee; Sanyal, Bhaskar; Chung, Namhyeok; Lee, Hyun-Gyu; Park, Yunji; Park, Hae-Jun; Kwon, Joong-Ho

    2015-06-01

    Photostimulated luminescence (PSL) has been employed as a fast screening method for various irradiated foods. In this study the potential use of PSL was evaluated to identify oranges irradiated with gamma ray, electron beam and X-ray (0-2 kGy) and stored under different conditions for 6 weeks. The effects of light conditions (natural light, artificial light, and dark) and storage temperatures (4 and 20 °C) on PSL photon counts (PCs) during post-irradiation periods were studied. Non-irradiated samples always showed negative values of PCs, while irradiated oranges exhibited intermediate results after first PSL measurements. However, the irradiated samples had much higher PCs. The PCs of all the samples declined as the storage time increased. Calibrated second PSL measurements showed PSL ratio <10 for the irradiated samples after 3 weeks of irradiation confirming their irradiation status in all the storage conditions. Calibrated PSL and sample storage in dark at 4 °C were found out to be most suitable approaches to identify irradiated oranges during storage.

  2. Real - time Optimization of Distributed Energy Storage System Operation Strategy Based on Peak Load Shifting

    Science.gov (United States)

    Wang, Qian; Lu, Guangqi; Li, Xiaoyu; Zhang, Yichi; Yun, Zejian; Bian, Di

    2018-01-01

    To take advantage of the energy storage system (ESS) sufficiently, the factors that the service life of the distributed energy storage system (DESS) and the load should be considered when establishing optimization model. To reduce the complexity of the load shifting of DESS in the solution procedure, the loss coefficient and the equal capacity ratio distribution principle were adopted in this paper. Firstly, the model was established considering the constraint conditions of the cycles, depth, power of the charge-discharge of the ESS, the typical daily load curves, as well. Then, dynamic programming method was used to real-time solve the model in which the difference of power Δs, the real-time revised energy storage capacity Sk and the permission error of depth of charge-discharge were introduced to optimize the solution process. The simulation results show that the optimized results was achieved when the load shifting in the load variance was not considered which means the charge-discharge of the energy storage system was not executed. In the meantime, the service life of the ESS would increase.

  3. Influence of different storage times and temperatures on blood gas and acid-base balance in ovine venous blood

    Directory of Open Access Journals (Sweden)

    H.A. Hussein

    2013-01-01

    Full Text Available The present study was designed to investigate the effects of storage temperature and time on blood gas and acid-base balance of ovine venous blood. Ten clinically healthy sheep were used in this study. A total number of 30 blood samples, were divided into three different groups, and were stored in a refrigerator adjusted to +4 ºC (Group I, n = 10, at RT of about 22-25 ºC (Group II, n = 10 and in an incubator adjusted to 37 ºC (Group III, n = 10 for up to 48 h. Blood samples were analysed for blood gas and acid-base indices at 0, 1, 2, 3, 4, 5, 6, 12, 24 and 48 h of storage. In comparison to the baseline value (0, there were significant decreases of blood pH of samples stored at RT and in the incubator after 1 h (p<0.05, the pH value of refrigerated blood samples exhibited insignificant changes during the study (p<0.05. Mean values of pCO2 showed a significant increase in Group I and Group III after 1 h then a progressive decrease after 12 h in all Groups. Mean pO2 values were significantly higher for Group I after 2 h and for Groups II and III after 1 h (p<0.05. In general, base excess decreased significantly for all the groups during the study especially in Groups II and III. In comparison with baseline values, in all groups, bicarbonate (HCO3 increased between 1 h and 6 h (p<0.05, and later decreased at the end of the study (p<0.05. In conclusion, status of acid-base indices of the samples stored at refrigerator and RT were found within normal reference range and it may be of clinical diagnostic use for up to 6 h.

  4. Sample handling for mass spectrometric proteomic investigations of human urine.

    Science.gov (United States)

    Petri, Anette Lykke; Høgdall, Claus; Christensen, Ib Jarle; Simonsen, Anja Hviid; T'jampens, Davy; Hellmann, Marja-Leena; Kjaer, Susanne Krüger; Fung, Eric T; Høgdall, Estrid

    2008-09-01

    Because of its non-invasive sample collection method, human urine is an attractive biological material both for discovering biomarkers and for use in future screening trials for different diseases. Before urine can be used for these applications, standardized protocols for sample handling that optimize protein stability are required. In this explorative study, we examine the influence of different urine collection methods, storage temperatures, storage times, and repetitive freeze-thaw procedures on the protein profiles obtained by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Prospectively collected urine samples from 11 women were collected as either morning or midday specimens. The effects of storage temperature, time to freezing, and freeze-thaw cycles were assessed by calculating the number, intensity, and reproducibility of peaks visualized by SELDI-TOF-MS. On the CM10 array, 122 peaks were detected and 28 peaks were found to be significantly different between urine types, storage temperature and time to freezing. On the IMAC-Cu array, 65 peaks were detected and 1 peak was found to be significantly different according to time to freezing. No significant differences were demonstrated for freeze-thaw cycles. Optimal handling and storage conditions are necessary in clinical urine proteomic investigations. Collection of urine with a single and consistently performed protocol is needed to reduce analytical bias. Collecting only one urine type, which is stored for a limited period at 4°C until freezing at -80°C prior to analysis will provide the most stable profiles. Copyright © 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Use of FTA cards for the storage of breast carcinoma nucleic acid on fine-needle aspiration samples.

    Science.gov (United States)

    Peluso, Anna Lucia; Cascone, Anna Maria; Lucchese, Lucrezia; Cozzolino, Immacolata; Ieni, Antonio; Mignogna, Chiara; Pepe, Stefano; Zeppa, Pio

    2015-10-01

    The preservation and storage of nucleic acids is important for DNA molecular techniques. The material obtained by fine-needle aspiration (FNA) is often scanty and can not be wasted. FTA cards are filter papers that immobilize and stabilize nucleic acids and can be stored at room temperature. The current study evaluated whether nucleic acids of breast carcinoma cells, obtained by FNA in a clinical setting, may be collected, stored, and preserved on FTA cards. Thirty breast carcinoma, 5 non-Hodgkin lymphoma (NHL), and 5 benign reactive lymph node (RLN) cell samples obtained by FNA were stored at -80 °C and on FTA cards. DNA extraction and polymerase chain reaction were performed on cells at -80 °C and on 2 punched disks of FTA cards. Fifty nanograms of extracted DNA from both sample types were used to amplify the Janus Kinase 2 (JAK2) gene. The mean value of DNA extracted from breast carcinoma cells was 28.19 ng/µL for that stored at -80 °C and 3.28 ng/µL for that stored on FTA cards. Agarose gel analysis demonstrated expected bands of DNA in 29 cases (97%) with both methods. The mean value of DNA extracted from NHL and RLN samples was 37.54 ng/µL and 4.28 ng/µL, respectively, and agarose gel analysis demonstrated bands of high molecular weight DNA in both methods. Significant differences in DNA yield were found between storage at -80 °C and FTA cards (PFTA cards can be conveniently used for the storage of breast carcinoma cells obtained by FNA, thus providing a reliable alternative to traditional methods. © 2015 American Cancer Society.

  6. Effects of Holding Time, Storage, and the Preservation of ...

    Science.gov (United States)

    The purpose of this project was to answer questions related to storage of samples to be analyzed by the quantitative polymerase chain reaction (qPCR)-based assays for fecal indicator bacteria. The project was divided into two parts. The first part was to determine if filters that were used to collect fecal indicators could be stored frozen and analyzed at a later date and the second part was to determine if refrigerated water samples could be held for 24 to 48 hours prior to analysis by qPCR. Both of these studies answer questions that were important in the analysis of fresh and marine surface water samples for beach monitoring purposes. 1) Develop and evaluate qPCR assays and test methods for the detection and quantification of genetic markers from indicator bacteria that are associated with human fecal waste and from two new groups of general fecal indicator bacteria (E. coli and Clostridia) that historically have been widely used or are favored in specific regions 2) Determine the occurrence and densities of genetic markers detected by new qPCR assays developed under objective 1 and compare with occurrence and densities of genetic markers detected by previously developed qPCR assays for enterococci and total Bacterioidalesin waste waters and fecal material from different animal sources. 3) Determine stability of fecal indicator bacteria target DNA sequences in freezer archived filter retentates of ambient surface water samples 4) Determine the densitie

  7. Long storage stability of biodiesel from vegetable and used frying oils

    Energy Technology Data Exchange (ETDEWEB)

    Abderrahim Bouaid; Mercedes Martinez; Jose Aracil [Complutense University, Madrid (Spain). Department of Chemical Engineering

    2007-11-15

    Biodiesel is defined as the mono-alkyl esters of vegetable oils. Production of biodiesel has grown tremendously in European Union in the last years. Though the commercial prospects for biodiesel have also grown, there remains some concern with respect to its resistance to oxidative degradation during storage. Due to the chemical structure of biodiesel the presence of the double bond in the molecule produce a high level of reactivity with the oxygen, especially when it placed in contact with air. Consequently, storage of biodiesel over extended periods may lead to degradation of fuel properties that can compromise fuel quality. This study used samples of biodiesel prepared by the process of transesterification from different vegetable oils: high oleic sunflower oil (HOSO), high and low erucic Brassica carinata oil (HEBO and LEBO) respectively and used frying oil (UFO). These biodiesels, produced from different sources, were used to determine the effects of long storage under different conditions on oxidation stability. Samples were stored in white (exposed) and amber (not exposed) glass containers at room temperature. The study was conducted for a period of 30-months. At regular intervals, samples were taken to measure the following physicochemical quality parameters: acid value (AV), peroxide value (PV), viscosity {nu}, iodine value (IV) and insoluble impurities (II). Results showed that AV, PV, {nu} and II increased, while IV decreased with increasing storage time of biodiesel samples. However, slight differences were found between biodiesel samples exposed and not exposed to daylight before a storage time of 12 months. But after this period the differences were significant. 22 refs., 5 figs., 3 tabs.

  8. Thermal energy storage apparatus, controllers and thermal energy storage control methods

    Science.gov (United States)

    Hammerstrom, Donald J.

    2016-05-03

    Thermal energy storage apparatus, controllers and thermal energy storage control methods are described. According to one aspect, a thermal energy storage apparatus controller includes processing circuitry configured to access first information which is indicative of surpluses and deficiencies of electrical energy upon an electrical power system at a plurality of moments in time, access second information which is indicative of temperature of a thermal energy storage medium at a plurality of moments in time, and use the first and second information to control an amount of electrical energy which is utilized by a heating element to heat the thermal energy storage medium at a plurality of moments in time.

  9. Evaluation of volatile profiles obtained for minimally-processed pineapple fruit samples during storage by headspace-solid phase microextraction gas chromatography-mass spectrometry

    Directory of Open Access Journals (Sweden)

    Francielle Crocetta TURAZZI

    Full Text Available Abstract This paper describes the application of the solid-phase microextraction (SPME technique for the determination and monitoring of the volatile profile of minimally-processed pineapple fruit stored at various temperatures (-12 °C, 4 °C and 25 °C for different periods (1, 4 and 10 days. The SPME fiber coating composed of Car/PDMS presented the best performance. The optimal extraction conditions obtained through a Doehlert design were 60 min at 35 °C. The profiles for the volatile compounds content of the fruit at each stage of storage were determined by gas chromatography-mass spectrometry (GC-MS. The variation in the volatile profile over time was greater when the fruit samples were stored at 25 °C and at -12 °C compared to 4 °C. Thus, according to the volatile profiles associated with the storage conditions evaluated in this study, packaged pineapple retains best its fresh fruit aroma when stored at 4 °C.

  10. Recovery of Pu from PVC vials and bottles used for sample storage

    International Nuclear Information System (INIS)

    Purohit, Paru; Bhide, M.K.; Kulkarni, M.J.; Kumar, Mithlesh; Adya, V.C.; Hon, N.S.; Kadam, R.M.; Nathaniel, Newton; Natarajan, V.

    2011-01-01

    Plutonium in the form of oxide is stored in plastic vials and bottles during its analysis for trace metal as say. Due to radiation damage and moisture, small amount of oxide samples were found to be adhering to surface of vials/ bottles. This required methods for safe disposal. Methods involving wet chemical and dry cleaning procedures were evaluated for effective removal of sticking α active plutonium oxide powder from these vials for their safe disposal. Dry cleaning method for removal of plutonium activity was found to be effective method for disposal of storage vial, while wet chemical method was found to be more suitable for removal of plutonium from damaged PVC bottles. (author)

  11. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF URINE SAMPLES FOR METALS AND PESTICIDES ANALYSIS (UA-F-20.1)

    Science.gov (United States)

    The purpose of this SOP is to guide the collection, storage, and shipment of urine samples collected. This SOP provides a brief description of sample, collection, preservation, storage, shipping, and custody procedures. This procedure was followed to ensure consistent data retri...

  12. Long-term frozen storage of urine samples: a trouble to get PCR results in Schistosoma spp. DNA detection?

    Science.gov (United States)

    Fernández-Soto, Pedro; Velasco Tirado, Virginia; Carranza Rodríguez, Cristina; Pérez-Arellano, José Luis; Muro, Antonio

    2013-01-01

    Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples' storage or conditions for handling and DNA preservation and extraction methods. We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patients urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template. Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA method of extraction used.

  13. Importance Sampling for Stochastic Timed Automata

    DEFF Research Database (Denmark)

    Jegourel, Cyrille; Larsen, Kim Guldstrand; Legay, Axel

    2016-01-01

    We present an importance sampling framework that combines symbolic analysis and simulation to estimate the probability of rare reachability properties in stochastic timed automata. By means of symbolic exploration, our framework first identifies states that cannot reach the goal. A state-wise cha......We present an importance sampling framework that combines symbolic analysis and simulation to estimate the probability of rare reachability properties in stochastic timed automata. By means of symbolic exploration, our framework first identifies states that cannot reach the goal. A state...

  14. Hydrogen storage in sonicated carbon materials

    NARCIS (Netherlands)

    Hirscher, M.; Becher, M.; Haluska, M.; Dettlaff-Weglikowska, U.; Quintel, A.; Duesberg, G.S.; Choi, Y.J.; Downes, P.; Hulman, M.; Roth, S.; Stepanek, I.; Bernier, P.

    2001-01-01

    The hydrogen storage in purified single-wall carbon nanotubes (SWNTs), graphite and diamond powder was investigated at room temperature and ambient pressure. The samples were sonicated in 5 M HNO3 for various periods of time using an ultrasonic probe of the alloy Ti-6Al-4V. The goal of this

  15. Radioactive waste on-site storage alternative

    International Nuclear Information System (INIS)

    Dufrane, K.H.

    1983-01-01

    The first, most frequently evaluated approach for the large producer is the construction of a relatively expensive storage building. However, with the likely possibility that at least one disposal site will remain available and the building never used, such expenditures are difficult to justify. A low cost, but effective alternative, is the use of ''On-Site Storage Containers'' (OSSC) when and if required. Radwaste is only stored in the OSSC if a disposal site is not available. A small number of OSSC's would be purchased initially just to assure immediate access to storage. Only in the unlikely event of total disposal sites closure would additional OSSC's have to be obtained and even this is cost effective. With two or three months of storage available on site, production lead time is sufficient for the delivery of additional units at a rate faster than the waste can be produced. The recommended OSSC design would be sized and shielding optimized to meet the needs of the waste generator. Normally, this would duplicate the shipping containers (casks or vans) currently in use. The reinforced concrete design presented is suitable for outside storage, contains a leakproof polyethylene liner and has remote sampling capability. Licensing would be under 10CFR50.59 for interim storage with long-term storage under 10CFR30 not an impossibility. Cost comparisons of this approach vs. building construction show that for a typical reactor plant installation, the OSSC offers direct savings even under the worst case assumption that no disposal sites are available and the time value of money is zero

  16. Sampling method, storage and pretreatment of sediment affect AVS concentrations with consequences for bioassay responses.

    Science.gov (United States)

    De Lange, H J; Van Griethuysen, C; Koelmans, A A

    2008-01-01

    Sediment treatment and sediment storage may alter sediment toxicity, and consequently biotic response. Purpose of our study was to combine these three aspects (treatment-toxicity-biotic response) in one integrated approach. We used Acid Volatile Sulfide (AVS) concentrations as a proxy of the disturbance of the sediment. AVS and Simultaneously Extracted Metal (SEM) concentrations were compared to bioassay responses with the freshwater benthic macroinvertebrate Asellus aquaticus. Storage conditions and sediment treatment affected AVS but not SEM levels. AVS can be used as a proxy for sediment disturbance. The best way to pretreat the sediment for use in a bioassay in order to maintain initial AVS conditions was to sample the sediment with an Ekman grab, immediately store it in a jar without headspace, and freeze it as soon as possible. In a survey using seven different sediments, bioassay responses of A. aquaticus were correlated with SEM and AVS characteristics.

  17. Influence of bottle storage time on colour, phenolic composition and sensory properties of sweet red wines.

    Science.gov (United States)

    Marquez, Ana; Serratosa, Maria P; Merida, Julieta

    2014-03-01

    Changes in colour and phenolic composition in sweet red wines made from Merlot, Syrah and Tempranillo grapes were studied in order to assess the influence of bottle storage over a period of 12months. For this purpose, wine colour parameters, sensory analysis and concentrations of monomeric anthocyanins, pyranoanthocyanins, methylmethine-mediated condensation adducts, flavan3-ol derivatives and flavonols were measured. Hue increased and red colours decreased with the storage time, particularly over the first 3months. The concentrations of low molecular weight flavan-3-ol derivatives decreased with time due to the effect of their conversion into tannins of high molecular weight. In addition, the glycosylated flavonols decreased through hydrolysis to give the corresponding aglycones. Overall, the concentration of phenolic compounds decreased markedly with storage time, whereas the antioxidant activity in the wines remained constant throughout. A panel of expert tasters judged the colour, aroma and flavour of all initial and final wines to be acceptable. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. THE QUALITY OFSUMBAWAHORSE MILKATROOM TEMPERATURE STORAGE

    Directory of Open Access Journals (Sweden)

    I Nengah Kerta Besung

    2017-07-01

    Full Text Available Research has been conducted to determine the quality of Sumbawa horse milk at room temperature storage. Each sample (of 5 horse was divided into 5 cups Beaker and then stored at room temperature. Observations were made as many as 6 times to checked and tested on parameters including pH, alcohol, smell and a flavor test. This study uses a randomized block design (RBD, using 5 horses as a group, and time observations on days 0, 1st, 2nd, 3rd, 4th, and 5th as a treatment, so tested 30 samples. The results showed that the pH of milk has significantly (P>0,05 lower quality. On the alcohol test showed positive results and the test on the smell and flavor test shaved changes quality after the 2nd day. Of observations Sumbawa horse milk quality decrease very markedly decreased pH (P0.05 decreased from day 2 to day 3 during storage. Alcohol test resistance at Sumbawa horse milk increasingly distorted and react positively. On the smell and flavor test Sumbawa horse milk taste very significant (P<0.01 deviates smells during storage at room temperature begins 2nd day. To maintain the quality of Sumbawa horse milk should be stored no more than 2 days at room.

  19. Time-Scale and Time-Frequency Analyses of Irregularly Sampled Astronomical Time Series

    Directory of Open Access Journals (Sweden)

    S. Roques

    2005-09-01

    Full Text Available We evaluate the quality of spectral restoration in the case of irregular sampled signals in astronomy. We study in details a time-scale method leading to a global wavelet spectrum comparable to the Fourier period, and a time-frequency matching pursuit allowing us to identify the frequencies and to control the error propagation. In both cases, the signals are first resampled with a linear interpolation. Both results are compared with those obtained using Lomb's periodogram and using the weighted waveletZ-transform developed in astronomy for unevenly sampled variable stars observations. These approaches are applied to simulations and to light variations of four variable stars. This leads to the conclusion that the matching pursuit is more efficient for recovering the spectral contents of a pulsating star, even with a preliminary resampling. In particular, the results are almost independent of the quality of the initial irregular sampling.

  20. Calibrated photostimulated luminescence is an effective approach to identify irradiated orange during storage

    International Nuclear Information System (INIS)

    Jo, Yunhee; Sanyal, Bhaskar; Chung, Namhyeok; Lee, Hyun-Gyu; Park, Yunji; Park, Hae-Jun; Kwon, Joong-Ho

    2015-01-01

    Photostimulated luminescence (PSL) has been employed as a fast screening method for various irradiated foods. In this study the potential use of PSL was evaluated to identify oranges irradiated with gamma ray, electron beam and X-ray (0–2 kGy) and stored under different conditions for 6 weeks. The effects of light conditions (natural light, artificial light, and dark) and storage temperatures (4 and 20 °C) on PSL photon counts (PCs) during post-irradiation periods were studied. Non-irradiated samples always showed negative values of PCs, while irradiated oranges exhibited intermediate results after first PSL measurements. However, the irradiated samples had much higher PCs. The PCs of all the samples declined as the storage time increased. Calibrated second PSL measurements showed PSL ratio <10 for the irradiated samples after 3 weeks of irradiation confirming their irradiation status in all the storage conditions. Calibrated PSL and sample storage in dark at 4 °C were found out to be most suitable approaches to identify irradiated oranges during storage. - Highlights: • Photostimulatedluminescence (PSL) was studied to identify irradiated orange for quarantine application. • PSL detection efficiency was compared amonggamma,electron, and X irradiation during shelf-life of oranges • PSL properties of samples were characterized by standard samples • Calibrated PSL gave a clear verdict on irradiation extending potential of PSL technique

  1. Tools for Inspecting and Sampling Waste in Underground Radioactive Storage Tanks with Small Access Riser Openings

    International Nuclear Information System (INIS)

    Nance, T.A.

    1998-01-01

    Underground storage tanks with 2 inches to 3 inches diameter access ports at the Department of Energy's Savannah River Site have been used to store radioactive solvents and sludge. In order to close these tanks, the contents of the tanks need to first be quantified in terms of volume and chemical and radioactive characteristics. To provide information on the volume of waste contained within the tanks, a small remote inspection system was needed. This inspection system was designed to provide lighting and provide pan and tilt capabilities in an inexpensive package with zoom abilities and color video. This system also needed to be utilized inside of a plastic tent built over the access port to contain any contamination exiting from the port. This system had to be build to travel into the small port opening, through the riser pipe, into the tank evacuated space, and out of the riser pipe and access port with no possibility of being caught and blocking the access riser. Long thin plates were found in many access riser pipes that blocked the inspection system from penetrating into the tank interiors. Retrieval tools to clear the plates from the tanks using developed sampling devices while providing safe containment for the samples. This paper will discuss the inspection systems, tools for clearing access pipes, and solvent sampling tools developed to evaluate the tank contents of the underground solvent storage tanks

  2. Determination of atmospheric nitrogen dioxide by sampling with impregnated filters

    International Nuclear Information System (INIS)

    Galiano, J.A.; Palomares, F.

    1978-01-01

    The performance of filters impregnated with triethanolamine for the collection and subsequent determination of atmospheric nitrogen dioxide is studied taking into account the influence of several parameters: storage of filters, reagents, elapsed time, sampling efficiency, etc. The results obtained for sampling times of 24 hours are satisfactory. (author) [es

  3. Study on the storage properties of irradiated ginger

    International Nuclear Information System (INIS)

    Wang Shoujing; Yu Zihou; Sun Shouyi; Zou Jiwan; Zhang Qizhi; Sun Hongchun; Lv Tiexin; Liu Xiaoyong

    2004-01-01

    The γ-ray irradiation could cause the loss of Vc during the early stage of storage, however, after 150 days' storage there were no significant differences of Vc content between irradiated and non-irradiated samples. The content of reduced sugar was increased by irradiation especially with 150 and 250 Gy. When ginger were irradiated with 250 Gy and stored at room temperature for 120 days, the content of Met and Arg decreased obviously, but the contents of other 16 amino acids were not affected. The respiration rate of irradiated ginger reached its peak at 7-9 days of storage, and from then it kept lower level for the rest storage time. The electrolyte permeability increased slightly after γ-irradiation. Irradiation with 80-400 Gy had no effects on lipid isoenzyme zymogram

  4. Effect of gamma irradiation and storage time on microbial growth and physicochemical characteristics of pumpkin (Cucurbita Moschata Duchesne ex Poiret) puree.

    Science.gov (United States)

    Gliemmo, María F; Latorre, María E; Narvaiz, Patricia; Campos, Carmen A; Gerschenson, Lía N

    2014-01-01

    The effect of gamma irradiation (0-2 kGy) and storage time (0-28 days) on microbial growth and physicochemical characteristics of a packed pumpkin puree was studied. For that purpose, a factorial design was applied. The puree contained potassium sorbate, glucose and vanillin was stored at 25°C . Gamma irradiation diminished and storage time increased microbial growth. A synergistic effect between both variables on microbial growth was observed. Storage time decreased pH and color of purees. Sorbate content decreased with storage time and gamma irradiation. Mathematical models of microbial growth generated by the factorial design allowed estimating that a puree absorbing 1.63 kGy would have a shelf-life of 4 days. In order to improve this time, some changes in the applied hurdles were assayed. These included a thermal treatment before irradiation, a reduction of irradiation dose to 0.75 kGy and a decrease in storage temperature at 20°C . As a result, the shelf-life of purees increased to 28 days.

  5. Storage Rings

    International Nuclear Information System (INIS)

    Fischer, W.

    2010-01-01

    Storage rings are circular machines that store particle beams at a constant energy. Beams are stored in rings without acceleration for a number of reasons (Tab. 1). Storage rings are used in high-energy, nuclear, atomic, and molecular physics, as well as for experiments in chemistry, material and life sciences. Parameters for storage rings such as particle species, energy, beam intensity, beam size, and store time vary widely depending on the application. The beam must be injected into a storage ring but may not be extracted (Fig. 1). Accelerator rings such as synchrotrons are used as storage rings before and after acceleration. Particles stored in rings include electrons and positrons; muons; protons and anti-protons; neutrons; light and heavy, positive and negative, atomic ions of various charge states; molecular and cluster ions, and neutral polar molecules. Spin polarized beams of electrons, positrons, and protons were stored. The kinetic energy of the stored particles ranges from 10 -6 eV to 3.5 x 10 12 eV (LHC, 7 x 10 12 eV planned), the number of stored particles from one (ESR) to 1015 (ISR). To store beam in rings requires bending (dipoles) and transverse focusing (quadrupoles). Higher order multipoles are used to correct chromatic aberrations, to suppress instabilities, and to compensate for nonlinear field errors of dipoles and quadrupoles. Magnetic multipole functions can be combined in magnets. Beams are stored bunched with radio frequency systems, and unbunched. The magnetic lattice and radio frequency system are designed to ensure the stability of transverse and longitudinal motion. New technologies allow for better storage rings. With strong focusing the beam pipe dimensions became much smaller than previously possible. For a given circumference superconducting magnets make higher energies possible, and superconducting radio frequency systems allow for efficient replenishment of synchrotron radiation losses of large current electron or positron beams

  6. Locally Minimum Storage Regenerating Codes in Distributed Cloud Storage Systems

    Institute of Scientific and Technical Information of China (English)

    Jing Wang; Wei Luo; Wei Liang; Xiangyang Liu; Xiaodai Dong

    2017-01-01

    In distributed cloud storage sys-tems, inevitably there exist multiple node fail-ures at the same time. The existing methods of regenerating codes, including minimum storage regenerating (MSR) codes and mini-mum bandwidth regenerating (MBR) codes, are mainly to repair one single or several failed nodes, unable to meet the repair need of distributed cloud storage systems. In this paper, we present locally minimum storage re-generating (LMSR) codes to recover multiple failed nodes at the same time. Specifically, the nodes in distributed cloud storage systems are divided into multiple local groups, and in each local group (4, 2) or (5, 3) MSR codes are constructed. Moreover, the grouping method of storage nodes and the repairing process of failed nodes in local groups are studied. The-oretical analysis shows that LMSR codes can achieve the same storage overhead as MSR codes. Furthermore, we verify by means of simulation that, compared with MSR codes, LMSR codes can reduce the repair bandwidth and disk I/O overhead effectively.

  7. Effect of storage time on microbial quality of some spices and dried ...

    African Journals Online (AJOL)

    The effect of storage time on the microbial quality of some spices and dried seasonings (SDS) (dawadawa, pepper, ginger, shrimp and fish powders) was studied over a 12-month period. Microbial load and profile of irradiated and unirradiated SDS were assessed at 0, 6 and 12-month periods. The range of total variable ...

  8. The impact of baking time and bread storage temperature on bread crumb properties.

    Science.gov (United States)

    Bosmans, Geertrui M; Lagrain, Bert; Fierens, Ellen; Delcour, Jan A

    2013-12-15

    Two baking times (9 and 24 min) and storage temperatures (4 and 25 °C) were used to explore the impact of heat exposure during bread baking and subsequent storage on amylopectin retrogradation, water mobility, and bread crumb firming. Shorter baking resulted in less retrogradation, a less extended starch network and smaller changes in crumb firmness and elasticity. A lower storage temperature resulted in faster retrogradation, a more rigid starch network with more water inclusion and larger changes in crumb firmness and elasticity. Crumb to crust moisture migration was lower for breads baked shorter and stored at lower temperature, resulting in better plasticized biopolymer networks in crumb. Network stiffening, therefore, contributed less to crumb firmness. A negative relation was found between proton mobilities of water and biopolymers in the crumb gel network and crumb firmness. The slope of this linear function was indicative for the strength of the starch network. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. A novel apparatus for the investigation of material properties for the storage of ultracold neutrons

    International Nuclear Information System (INIS)

    Brys, T.; Daum, M.; Fierlinger, P.; Geltenbort, P.; George, D.; Gupta, M.; Henneck, R.; Heule, S.; Horvat, M.; Kasprzak, M.; Kirch, K.; Kohlik, K.; Negrazus, M.; Pichlmaier, A.; Straumann, U.; Vrankovic, V.; Wermelinger, C.

    2005-01-01

    We have built a novel apparatus for the investigation of materials for the storage of ultracold neutrons. Neutrons are filled into a storage volume, confined at the bottom by a magnetic field, at the top by gravity and at the sides by the slit-less sample surface under investigation. For different beryllium and diamond-like carbon samples, storage times up to 200s were obtained at room temperature. The corresponding loss parameters η for ultracold neutrons varied between 4.2 and 6.8x10 -4 per wall collision

  10. [Fatty acids in mature breast milk from low socioeconomic levels of Venezuelan women: influence of temperature and time of storage].

    Science.gov (United States)

    Bosch, Virgilio; Golfetto, Iván; Alonso, Hilda; Laurentin, Zuly; Materan, Mercedes; García, Ninoska

    2009-03-01

    Fatty acids in mature breast milk from low socioeconomic levels of Venezuelan women: influence of temperature and time of storage. Breast milk is the main food in infants from birth until six months old. It is important to know if precarious life conditions could limit some nutrients in mother's milk. The objective of this study is to evaluate the total fat and essential long chain fatty acids in mature breast milk from low socioeconomic levels in Venezuelan women. The values of total fat (3.56 +/- 1.18 g/%) are similar that reported in the literature, however the sume of LC-PUFA n-3 was 0.3 +/- 0.04% which is related whith low n-3 fatty acid maternal diet.The sume LC-PUFA n-3 contained in this study is below most of the reviewed publications. The average amount of 22:6 n-3 in breast milk offered to newborn one month old (750 ml/day) is below estimated requirements (70 mg/day). The majority of these samples provide to the infants, the amount of DHA estimated as convenient to sustain normal growth. Also it was explored how the time (8h to 24 h) and temperatura (+4 degrees C, +15 degrees C, and +25 degrees C) can affect its composition. This data will permit to select the best condiitions of sampling and storage of mother's milk in future investigations in different regions of Venezuela. Most of the breast milk fatty acids tolerate some hours at room temperature (25 degrees C) but essential long chain fatty acids are very vulnerable. We propose that, in consequence, that samples should be transported in sterile conditions in dry ice to the laboratory in a few hours and should be kept at -70 degrees C until their analysis.

  11. Sample-interpolation timing: an optimized technique for the digital measurement of time of flight for γ rays and neutrons at relatively low sampling rates

    International Nuclear Information System (INIS)

    Aspinall, M D; Joyce, M J; Mackin, R O; Jarrah, Z; Boston, A J; Nolan, P J; Peyton, A J; Hawkes, N P

    2009-01-01

    A unique, digital time pick-off method, known as sample-interpolation timing (SIT) is described. This method demonstrates the possibility of improved timing resolution for the digital measurement of time of flight compared with digital replica-analogue time pick-off methods for signals sampled at relatively low rates. Three analogue timing methods have been replicated in the digital domain (leading-edge, crossover and constant-fraction timing) for pulse data sampled at 8 GSa s −1 . Events arising from the 7 Li(p, n) 7 Be reaction have been detected with an EJ-301 organic liquid scintillator and recorded with a fast digital sampling oscilloscope. Sample-interpolation timing was developed solely for the digital domain and thus performs more efficiently on digital signals compared with analogue time pick-off methods replicated digitally, especially for fast signals that are sampled at rates that current affordable and portable devices can achieve. Sample interpolation can be applied to any analogue timing method replicated digitally and thus also has the potential to exploit the generic capabilities of analogue techniques with the benefits of operating in the digital domain. A threshold in sampling rate with respect to the signal pulse width is observed beyond which further improvements in timing resolution are not attained. This advance is relevant to many applications in which time-of-flight measurement is essential

  12. Wind power impacts and electricity storage - a time scale perspective

    DEFF Research Database (Denmark)

    Hedegaard, Karsten; Meibom, Peter

    2012-01-01

    Integrating large amounts of wind power in energy systems poses balancing challenges due to the variable and only partly predictable nature of wind. The challenges cover different time scales from intra-hour, intra-day/day-ahead to several days and seasonal level. Along with flexible electricity...... demand options, various electricity storage technologies are being discussed as candidates for contributing to large-scale wind power integration and these also differ in terms of the time scales at which they can operate. In this paper, using the case of Western Denmark in 2025 with an expected 57% wind...... power penetration, wind power impacts on different time scales are analysed. Results show consecutive negative and high net load period lengths indicating a significant potential for flexibility measures capable of charging/activating demand and discharging/inactivating demand in periods of 1 h to one...

  13. Effect of gamma irradiation on the storage and vitamin C concentration of allium cepa onion samples

    International Nuclear Information System (INIS)

    Saleh, M. A. M.

    2013-07-01

    This study was done to investigate the effect of gamma irradiation on storage, germination and vitamin C concentration of local onion (Allium cepa). 5 onion samples were irradiated with 5 different radiation doses (0.1, 0.2, 0.3, 0.4, and 0.5 k Gray) using cobalt-60 irradiator (Nor din) compared to non irradiated samples as controls. The irradiated and control onions were stored at room temperature for three months. The results of this study showed that the non irradiated samples were either deteriorated or grown while all the irradiated samples were not. Regarding the concentration of vitamin C it was clear that it decreased with the dose increase from 30.53 to 14.44 mg/100 g. This study concluded that the irradiation is very effective in prevention of spoilage, elongation of germination period and decrease of vitamin C concentration.(Author)

  14. Monitored Retrievable Storage conceptual system study: metal storage casks

    International Nuclear Information System (INIS)

    Unterzuber, R.; Cross, T.E.; Krasicki, B.R.

    1983-08-01

    A description of the metal cask storage facility concept is presented with the operations required to handle the spent fuel or high-level wastes and transuranic wastes. A generic Receiving and Handling Facility, provided by PNL, has been used for this study. Modifications to the storage delivery side of the handling facility, necessary to couple the Receiving and Handling Facility with the storage facility, are described. The equipment and support facilities needed for the storage facility are also described. Two separate storage facilities are presented herein: one for all spent fuel storage, and one for storage of high-level waste (HLW) and transuranic waste (TRU). Each facility is described for the capacities and rates defined by PNL in the Concept Technical Performance Criteria and Base Assumptions (see Table 1.3-1). Estimates of costs and time-distributions of expenditures have been developed to construct, operate, and decommission the conceptual MRS facilities in mid-1983 dollars, for the base cases given using the cost categories and percentages provided by PNL. Cost estimates and time-distributions of expenditures have also been developed to expand the facility throughput rate from 1800 MTU to 3000 MTU, and to expand the facility storage capacity from 15,000 MTU to 72,00 MTU. The life cycle cost of the facility for the bounding cases of all spent fuel and all HLW and TRU, using the time-distributions of costs developed above and assuming a two percent per year discount rate, are also presented. 3 references, 16 figures, 18 tables

  15. Sampled-data and discrete-time H2 optimal control

    NARCIS (Netherlands)

    Trentelman, Harry L.; Stoorvogel, Anton A.

    1993-01-01

    This paper deals with the sampled-data H2 optimal control problem. Given a linear time-invariant continuous-time system, the problem of minimizing the H2 performance over all sampled-data controllers with a fixed sampling period can be reduced to a pure discrete-time H2 optimal control problem. This

  16. Sampling and analysis plan for Wayne Interim Storage Site (WISS), Wayne, New Jersey

    International Nuclear Information System (INIS)

    Brown, K.S.; Murray, M.E.; Rodriguez, R.E.

    1998-10-01

    This field sampling plan describes the methodology to perform an independent radiological verification survey and chemical characterization of a remediated area of the subpile at the Wayne Interim Storage Site, Wayne, New Jersey.Data obtained from collection and analysis of systematic and biased soil samples will be used to assess the status of remediation at the site and verify the final radiological status. The objective of this plan is to describe the methods for obtaining sufficient and valid measurements and analytical data to supplement and verify a radiological profile already established by the Project Remediation Management Contractor (PMC). The plan describes the procedure for obtaining sufficient and valid analytical data on soil samples following remediation of the first layer of the subpile. Samples will be taken from an area of the subpile measuring approximately 30 m by 80 m from which soil has been excavated to a depth of approximately 20 feet to confirm that the soil beneath the excavated area does not exceed radiological guidelines established for the site or chemical regulatory limits for inorganic metals. After the WISS has been fully remediated, the Department of Energy will release it for industrial/commercial land use in accordance with the Record of Decision. This plan provides supplemental instructions to guidelines and procedures established for sampling and analysis activities. Procedures will be referenced throughout this plan as applicable, and are available for review if necessary

  17. Metabolomic analysis of platelets during storage

    DEFF Research Database (Denmark)

    Paglia, Giuseppe; Sigurjónsson, Ólafur E; Rolfsson, Óttar

    2015-01-01

    BACKGROUND: Platelet concentrates (PCs) can be prepared using three methods: platelet (PLT)-rich plasma, apheresis, and buffy coat. The aim of this study was to obtain a comprehensive data set that describes metabolism of buffy coat-derived PLTs during storage and to compare it with a previously...... published parallel data set obtained for apheresis-derived PLTs. STUDY DESIGN AND METHODS: During storage we measured more than 150 variables in 8 PLT units, prepared by the buffy coat method. Samples were collected at seven different time points resulting in a data set containing more than 8000...... after their collection. The transition was evident in PLT produced by both production methods. Apheresis-derived PLTs showed a clearer phenotype of PLT activation during early days of storage. The activated phenotype of apheresis PLTs was accompanied by a higher metabolic activity, especially related...

  18. Long-term frozen storage of urine samples: a trouble to get PCR results in Schistosoma spp. DNA detection?

    Directory of Open Access Journals (Sweden)

    Pedro Fernández-Soto

    Full Text Available BACKGROUND: Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples' storage or conditions for handling and DNA preservation and extraction methods. METHODOLOGY/PRINCIPAL FINDINGS: We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patients urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template. CONCLUSIONS/SIGNIFICANCE: Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA

  19. Six-month storage-time evaluation of one-bottle adhesive systems to dentin.

    Science.gov (United States)

    Giannini, Marcelo; Seixas, Carla Alessandra Marcelino; Reis, Andre Figueiredo; Pimenta, Luiz André Freire

    2003-01-01

    The goal of this study was to evaluate the 1-week, 3-month, and 6-month performance of eight commercially available one-bottle adhesive systems to dentin. Lingual and buccal surfaces from human third molars were ground wet on 600-grit SiC paper to obtain a flat dentinal surface. The specimens were randomly divided into 24 groups (n = 10), which were established to measure the shear bond strengths of Bond-1 (B1), ONE-STEP (OS), OptiBond SOLO (OP), Prime & Bond 2.1 (PB), Single Bond (SB), STAE (ST), Syntac Sprint (SS), and Tenure Quick (TQ) after 1-week, 3-month, and 6-month water storage at 37 degrees C. One-bottle adhesives were applied according to manufacturers' instructions and Z100 composite cylinders were applied on the bonded dentinal surfaces. The 3-month water-storage groups were thermocycled for 1500 cycles at 5 degrees C and 55 degrees C and 6-month groups for 3000 cycles. After storage periods, specimens were tested in shear in a universal testing machine (0.5 mm/min). were statistically analyzed by analysis of variance and Tukey test. Results: The changes in shear bond strengths were not uniform over time. Over the test period, OS, PB, SB, and SS exhibited bond strength stability, however, SS presented low bond strengths on all tested periods. A significant decrease in bond strength was observed for B1, OP, ST, and TQ after the 6-month storage period.

  20. Time-dependent importance sampling in semiclassical initial value representation calculations for time correlation functions.

    Science.gov (United States)

    Tao, Guohua; Miller, William H

    2011-07-14

    An efficient time-dependent importance sampling method is developed for the Monte Carlo calculation of time correlation functions via the initial value representation (IVR) of semiclassical (SC) theory. A prefactor-free time-dependent sampling function weights the importance of a trajectory based on the magnitude of its contribution to the time correlation function, and global trial moves are used to facilitate the efficient sampling the phase space of initial conditions. The method can be generally applied to sampling rare events efficiently while avoiding being trapped in a local region of the phase space. Results presented in the paper for two system-bath models demonstrate the efficiency of this new importance sampling method for full SC-IVR calculations.

  1. Changes in the carbohydrate and organic acid contents of tomatoes as a function of radiation dose and storage time

    Energy Technology Data Exchange (ETDEWEB)

    Kovacs, E [Kozponti Elelmiszeripari Kutato Intezet, Budapest (Hungary)

    1974-01-01

    Sugars and organic acids of tomatoes, variety Original Fruehrot, in different stages of development were examined by gas chromatography after silylation. Changes in the carbohydrate and organic acid content of half-ripe and ripe tomatoes were determined after treatment with different radiation doses (5, 15, 30, 60, 250 and 500 krad). Fructose, glucose, saccharose and malic acid could be detected in the tomato samples. The saccharose and malic acid contents of half-ripe tomatoes decreased as a result of irradiation with doses above 250 krad. In ripe tomatoes, the malic acid content fell most markedly under the influence of irradiation. The sugar content tended to decrease as a function of storage time, except for samples treated with 15 krad which usually delayed decomposition of the components tested. The effect of irradiation was more extensive in half-ripe tomatoes than in ripe ones.

  2. A multiple-orbit time-of-flight mass spectrometer based on a low energy electrostatic storage ring

    Science.gov (United States)

    Sullivan, M. R.; Spanjers, T. L.; Thorn, P. A.; Reddish, T. J.; Hammond, P.

    2012-11-01

    The results are presented for an electrostatic storage ring, consisting of two hemispherical deflector analyzers (HDA) connected by two separate sets of cylindrical lenses, used as a time-of-flight mass spectrometer. Based on the results of charged particle simulations and formal matrix model, the Ion Storage Ring is capable of operating with multiple stable orbits, for both single and multiply charged ions simultaneously.

  3. Changes in cod muscle proteins during frozen storage revealed by proteome analysis and multivariate data analysis

    DEFF Research Database (Denmark)

    Kjærsgård, Inger Vibeke Holst; Nørrelykke, M.R.; Jessen, Flemming

    2006-01-01

    Multivariate data analysis has been combined with proteomics to enhance the recovery of information from 2-DE of cod muscle proteins during different storage conditions. Proteins were extracted according to 11 different storage conditions and samples were resolved by 2-DE. Data generated by 2-DE...... was subjected to principal component analysis (PCA) and discriminant partial least squares regression (DPLSR). Applying PCA to 2-DE data revealed the samples to form groups according to frozen storage time, whereas differences due to different storage temperatures or chilled storage in modified atmosphere...... light chain 1, 2 and 3, triose-phosphate isomerase, glyceraldehyde-3-phosphate dehydrogenase, aldolase A and two ?-actin fragments, and a nuclease diphosphate kinase B fragment to change in concentration, during frozen storage. Application of proteomics, multivariate data analysis and MS/MS to analyse...

  4. Application of gamma irradiation for storage potato

    International Nuclear Information System (INIS)

    Rezaee, M.; Almasi, M.

    2009-01-01

    Since deficiency of controlled store in Iran and environmental problems of chemical material the use of gamma irradiation to control sprouting and increase the length of storage time of potatoes has been proposed as an alternative to cold storage or the use of chemical sprout suppressants. In this study potatoes of Agria Variety were irradiated at a dose of 0.10 KGY and stored along with the unirradiated controls at 12±3°C for a period of more than 6 month from October to April .After 4 month of storage the sprouting ranged from 5 to 12% in irradiated potatoes and 45 to 74% in unirradiated samples and after 6 month the unirradiated potatoes were discarded because of heavy sprouting and rotting. The rot attack was approximately double in unirradiated samples. It was found that losses through dehydration were 10.3 to 15.1 % in the irradiated potatoes. Also a comparative study of reducing and non-reducing sugars, vitamin-C content, total sugar, starch and protein was carried out between unirradiated and irradiated samples. The results suggested the efficacy of Gamma irradiation for ensuring availability of the storing quality of potato during lean periods from October to April. (author)

  5. Mahanaxar: quality of service guarantees in high-bandwidth, real-time streaming data storage

    Energy Technology Data Exchange (ETDEWEB)

    Bigelow, David [Los Alamos National Laboratory; Bent, John [Los Alamos National Laboratory; Chen, Hsing-Bung [Los Alamos National Laboratory; Brandt, Scott [UCSC

    2010-04-05

    Large radio telescopes, cyber-security systems monitoring real-time network traffic, and others have specialized data storage needs: guaranteed capture of an ultra-high-bandwidth data stream, retention of the data long enough to determine what is 'interesting,' retention of interesting data indefinitely, and concurrent read/write access to determine what data is interesting, without interrupting the ongoing capture of incoming data. Mahanaxar addresses this problem. Mahanaxar guarantees streaming real-time data capture at (nearly) the full rate of the raw device, allows concurrent read and write access to the device on a best-effort basis without interrupting the data capture, and retains data as long as possible given the available storage. It has built in mechanisms for reliability and indexing, can scale to meet arbitrary bandwidth requirements, and handles both small and large data elements equally well. Results from our prototype implementation shows that Mahanaxar provides both better guarantees and better performance than traditional file systems.

  6. Chemical Properties and Characteristics of Cow Milk Yogurt with Different Additional Fruit and Storage Time

    Directory of Open Access Journals (Sweden)

    Putri Dian Wulansari

    2016-05-01

    Full Text Available This research was aimed to evaluate the composition (total solids, water content, fat and protein, qualitative properties (color, aroma, and texture and quantitative properties (free fatty acid and lactic acid of cow milk yogurt with different fruits addition and storage time. Experimental method applied Completely Randomized Design with five treatments namely control, dragon fruit, mango, apple and banana (20% v/v, each with 5 replicates. Qualitative characteristic assessment was conducted on 0, 5, 10 and 15 days of storage. Result showed that fruit addition significantly affected the composition and characteristics, while storage time significantly affected quantitative characteristics of yogurt. Apple and banana increased 13% total solids of plain yogurt, while the highest fat content (4,516% was observed in control yogurt which had the lowest protein content (2,564. The highest free fatty acid  was in control yogurt ripen for 15 days (22,885% while the lowest free fatty acid was in mango yogurt ripen for 10 days (13,915%. Fruit addition in yogurt ripen for 15 days at 5C resulted in a safe consumed product.

  7. Function and platelet count in thrombocyte concentrate (TC during the storage

    Directory of Open Access Journals (Sweden)

    Elida Marpaung

    2016-01-01

    Full Text Available AbstrakLatar belakang: Evaluasi terhadap pemberian transfusi belum dilakukan secara optimal baik di hulumaupun di hilir. Tujuan penelitian ini untuk mengetahui pengaruh waktu penyimpanan terhadap perubahanpH, jumlah trombosit, dan fungsi agregasi yang terjadi pada trombosit pada beberapa hari penyimpanan.Metode: Disain penelitian potong lintang terhadap sample kantong konsentrat trombosit yang yang telahlolos skrining infeksi penyakit menular melalui transfusi darah. Pengujian yang dilakukan ialah terhadappH, jumlah trombosit dan fungsi agregasi terhadap sampel pada tiga waktu pengujian pada hari ke-0, ketiga, dan ke lima penyimpanan.Hasil: Pada 50 sampel kantong konsentrat trombosit didapatkan kenaikan pH pada hari ke tigapenyimpanan kantong trombosit yang disertai penurunan pada hari ke lima. Hal serupa ditemui pulapada jumlah trombosit. Sementara penurunan fungsi agregasi trombosit ditemukan lebih awal pada harike tiga penyimpanan dan didapatkan nilai rendah pada hampir semua sampel.Kesimpulan: Ketiga parameter yaitu pH, jumlah trombosit, dan fungsi agregasi mengalami penurunanpada hari kelima. (Health Science Journal of Indonesia;2015;6:48-51Kata kunci: thrombocyte, concentrate, pH, agregasi, waktu penyimpanan. AbstractBackground: Evaluation for platelet transfusion is not optimal for this moment even in upstream at theblood center or in downstream at the hospital. The purpose of this study was to determine the effect ofstorage time to changes in pH, platelet count and function that occurs on platelet aggregation duringdifferent time storage.Methods: The study design was cross-sectional on selected bags of platelet concentrates that have passedthe screening for infection transmitted through blood transfusions. The regular assessment in UTDD forPC has been done every month by random sampling with three parameters pH, platelets count and volumein the bag of blood. The testing for pH, platelet count, and aggregation functions for 50 samples

  8. The influence of storage duration on the setting time of type 1 alginate impression material

    Science.gov (United States)

    Rahmadina, A.; Triaminingsih, S.; Irawan, B.

    2017-08-01

    Alginate is one of the most commonly used dental impression materials; however, its setting time is subject to change depending on storage conditions and duration. This creates problems because consumer carelessness can affect alginate shelf life and quality. In the present study, the setting times of two groups of type I alginate with different expiry dates was tested. The first group consisted of 11 alginate specimens that had not yet passed the expiry date, and the second group consisted of alginates that had passed the expiry date. The alginate powder was mixed with distilled water, poured into a metal ring, and tested with a polished rod of poly-methyl methacrylate. Statistical analysis showed a significant difference (p<0.05) between the setting times of the alginate that had not passed the expiry date (157 ± 3 seconds) and alginate that had passed the expiry date (144 ± 2 seconds). These findings indicate that storage duration can affect alginate setting time.

  9. Effects of modified atmosphere, associated with masterpack transport packaging, and refrigerated storage time on the quality characteristics of pork loin cuts

    Directory of Open Access Journals (Sweden)

    Alessandra F. Rosa

    2013-10-01

    Full Text Available The objective of this research was to study the effects of modified atmosphere, associated with masterpack transport packaging, and refrigerated storage time on the quality characteristics of pork loin cuts. Cuts of pork loin were packaged in trays, covered with poly(vinyl chloride film. The trays were placed in a masterpack (MP, containing three gas compositions:  A 75% O2 : 25% CO2, B 50% O2 : 50% CO2 or C 100% CO2, and stored at 2 °C. Samples were taken after 1, 8, 15, and 22 days of storage, and evaluated for numerous shelf life traits. The development of Psychrotrophic aerobic bacteria and Pseudomonas spp. was found from the 15th day of storage. There was a significant treatment effect for some of the considered parameters, such as pH (P < 0.05 and color [L* (P < 0.07, a* (P < 0.07 and b* (P < 0.01]. There was a significant interaction (P < 0.01 for the TBARS values. It can be concluded, from the microbiological point of view, that the use of modified atmospheres containing 25% to 100% CO2 promotes the conservation of meat for up to 15 days of storage under refrigeration. From the point of view of color, atmospheres containing 75% O2 : 25% CO2 and 50% O2 : 50% CO2 ensure the color of packaged pork meat when stored at 2 °C for up to 15 days. From the point of view of lipid oxidation, packages with 100% CO2 are recommended for storage periods of more than 15 days, whereas those with 75% O2 : 25% CO2 are recommended for storage periods of up to 8 days.

  10. Sampling returns for realized variance calculations: tick time or transaction time?

    NARCIS (Netherlands)

    Griffin, J.E.; Oomen, R.C.A.

    2008-01-01

    This article introduces a new model for transaction prices in the presence of market microstructure noise in order to study the properties of the price process on two different time scales, namely, transaction time where prices are sampled with every transaction and tick time where prices are

  11. Water-induced morphology changes in BaO/?-Al2O3 NOx storage materials: an FTIR, TPD, and time-resolved synchrotron XRD study

    International Nuclear Information System (INIS)

    Szanyi, Janos; Kwak, Ja Hun; Kim, Do Heui; Wang, Xianqin; Chimentao, Ricardo J.; Hanson, Jonathan; Epling, William S.; Peden, Charles HF

    2007-01-01

    The effect of water on the morphology of BaO/Al2O3-based NOx storage materials was investigated using Fourier transform infrared spectroscopy, temperature programmed desorption, and time-resolved synchrotron X-ray diffraction techniques. The results of this multi-spectroscopy study reveal that, in the presence of water, surface Ba-nitrates convert to bulk nitrates, and water facilitates the formation of large Ba(NO3)2 particles. This process is completely reversible, i.e. after the removal of water from the storage material a significant fraction of the bulk nitrates re-convert to surface nitrates. NO2 exposure of a H2O-containing (wet) BaO/Al2O3 sample results in the formation of nitrites and bulk nitrates exclusively, i.e. no surface nitrates form. After further exposure to NO2, the nitrites completely convert to bulk nitrates. The amount of NOx taken up by the storage material is, however, essentially unaffected by the presence of water, regardless of whether the water was dosed prior to or after NO2 exposure. Based on the results of this study we are now able to explain most of the observations reported in the literature on the effect of water on NOx uptake on similar storage materials

  12. Effect of Storage Time of Extended-Pour and Conventional Alginate Impressions on Dimensional Accuracy of Casts

    OpenAIRE

    Rohanian, Ahmad; Ommati Shabestari, Ghasem; Zeighami, Somayeh; Samadi, Mohammad Javad; Shamshiri, Ahmad Reza

    2014-01-01

    Objectives: Some manufacturers claim to have produced new irreversible hydro-colloids that are able to maintain their dimensional stability during storage. The present study evaluated the effect of storage time on dimensional stability of three alginates: Hydrogum 5, Tropicalgin and Alginoplast. Materials and Methods: In this experimental in-vitro trial, a total of 90 alginate impressions were made from a Dentoform model using Hydrogum 5, Tropicalgin and Alginoplast alginates. The impressions...

  13. [DNA quantification of blood samples pre-treated with pyramidon].

    Science.gov (United States)

    Zhu, Chuan-Hong; Zheng, Dao-Li; Ni, Rao-Zhi; Wang, Hai-Sheng; Ning, Ping; Fang, Hui; Liu, Yan

    2014-06-01

    To study DNA quantification and STR typing of samples pre-treated with pyramidon. The blood samples of ten unrelated individuals were anticoagulated in EDTA. The blood stains were made on the filter paper. The experimental groups were divided into six groups in accordance with the storage time, 30 min, 1 h, 3 h, 6 h, 12 h and 24h after pre-treated with pyramidon. DNA was extracted by three methods: magnetic bead-based extraction, QIAcube DNA purification method and Chelex-100 method. The quantification of DNA was made by fluorescent quantitative PCR. STR typing was detected by PCR-STR fluorescent technology. In the same DNA extraction method, the sample DNA decreased gradually with times after pre-treatment with pyramidon. In the same storage time, the DNA quantification in different extraction methods had significant differences. Sixteen loci DNA typing were detected in 90.56% of samples. Pyramidon pre-treatment could cause DNA degradation, but effective STR typing can be achieved within 24 h. The magnetic bead-based extraction is the best method for STR profiling and DNA extraction.

  14. Influence of acidification, pasteurization, centrifugation and storage time and temperature on watermelon juice quality.

    Science.gov (United States)

    Tarazona-Díaz, Martha Patricia; Aguayo, Encarna

    2013-12-01

    Watermelon juice has gained increasing popularity among consumers as a rich natural source of functional compounds such as lycopene and citrulline. However, the final quality of the juice depends significantly on its acidification, pasteurization, centrifugation and storage time and temperature. In this study, these characteristics were assessed in watermelon juice pasteurized at 87.7 °C for 20 s and stored for up to 30 days at 4 or 8 °C. The acidifier citric acid provided an adequate sensory quality, similar to natural watermelon juice. Centrifugation and pasteurization significantly reduced the red color, bioactive compounds (lycopene, antioxidant capacity and total polyphenols) and sensory quality of the juice, particularly when the storage time was extended and a temperature of 8 °C was used (P ≤ 0.05). All treated juices were microbiologically safe for up to 30 days when stored at 4 or 8 °C. In terms of sensory acceptability, only non-centrifuged juices stored for up to 20 days at 4 °C remained above the commercial limit. The present results suggest that using a non-centrifugation process and a storage temperature of 4 °C yields a watermelon juice that better retains its sensory and functional qualities. © 2013 Society of Chemical Industry.

  15. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF URINE SAMPLES FOR METAL, PESTICIDE, AND CREATININE ANALYSIS (F10)

    Science.gov (United States)

    The purpose of this SOP is to describe the procedures for collection, storage, and shipment of urine samples for metal, pesticides, and creatinine analysis. Samples were collected on Days 2 and 8 of each Cycle. The Day 2 sample was analyzed for metals and creatinine. The Day 8...

  16. Sampling method, storage and pretreatment of sediment affect AVS concentrations with consequences for bioassay responses

    Energy Technology Data Exchange (ETDEWEB)

    Lange, H.J. de [Aquatic Ecology and Water Quality Management Group, Wageningen University, Wageningen University and Research Centre, P.O. Box 8080, 6700 DD, Wageningen (Netherlands); Centre for Ecosystem Studies, Alterra, Wageningen University and Research Centre, P.O. Box 47, 6700 AA, Wageningen (Netherlands)], E-mail: marieke.delange@wur.nl; Griethuysen, C. van; Koelmans, A.A. [Aquatic Ecology and Water Quality Management Group, Wageningen University, Wageningen University and Research Centre, P.O. Box 8080, 6700 DD, Wageningen (Netherlands)

    2008-01-15

    Sediment treatment and sediment storage may alter sediment toxicity, and consequently biotic response. Purpose of our study was to combine these three aspects (treatment-toxicity-biotic response) in one integrated approach. We used Acid Volatile Sulfide (AVS) concentrations as a proxy of the disturbance of the sediment. AVS and Simultaneously Extracted Metal (SEM) concentrations were compared to bioassay responses with the freshwater benthic macroinvertebrate Asellus aquaticus. Storage conditions and sediment treatment affected AVS but not SEM levels. AVS can be used as a proxy for sediment disturbance. The best way to pretreat the sediment for use in a bioassay in order to maintain initial AVS conditions was to sample the sediment with an Ekman grab, immediately store it in a jar without headspace, and freeze it as soon as possible. In a survey using seven different sediments, bioassay responses of A. aquaticus were correlated with SEM and AVS characteristics. - Change in AVS is a good proxy for sediment disturbance and combined with SEM it can be used as a suitable predictor for biotic effects of sediment contamination.

  17. Spent fuel storage requirements: the need for away-from-reactor storage

    International Nuclear Information System (INIS)

    1980-01-01

    The analyses of on-site storage capabilities of domestic utilities and estimates of timing and magnitude of away-from-reactor (AFR) storage requirements were presented in the report DOE/ET-0075 entitled Spent Fuel Storage Requirements: The Need For Away-From-Reactor Storage published in February 1979 by the US Department of Energy. Since utility plans and requirements continue to change with time, a need exists to update the AFR requirements estimates as appropriate. This short report updates the results presented in DOE/ET-0075 to reflect recent data on reactor operations and spent fuel storage. In addition to the updates of cases representing the range of AFR requirements in DOE/ET-0075, new cases of interest reflecting utility and regulatory trends are presented

  18. Analog storage integrated circuit

    Science.gov (United States)

    Walker, J.T.; Larsen, R.S.; Shapiro, S.L.

    1989-03-07

    A high speed data storage array is defined utilizing a unique cell design for high speed sampling of a rapidly changing signal. Each cell of the array includes two input gates between the signal input and a storage capacitor. The gates are controlled by a high speed row clock and low speed column clock so that the instantaneous analog value of the signal is only sampled and stored by each cell on coincidence of the two clocks. 6 figs.

  19. Gamma-hydroxybutyric acid endogenous production and post-mortem behaviour - the importance of different biological matrices, cut-off reference values, sample collection and storage conditions.

    Science.gov (United States)

    Castro, André L; Dias, Mário; Reis, Flávio; Teixeira, Helena M

    2014-10-01

    Gamma-Hydroxybutyric Acid (GHB) is an endogenous compound with a story of clinical use, since the 1960's. However, due to its secondary effects, it has become a controlled substance, entering the illicit market for recreational and "dance club scene" use, muscle enhancement purposes and drug-facilitated sexual assaults. Its endogenous context can bring some difficulties when interpreting, in a forensic context, the analytical values achieved in biological samples. This manuscript reviewed several crucial aspects related to GHB forensic toxicology evaluation, such as its post-mortem behaviour in biological samples; endogenous production values, whether in in vivo and in post-mortem samples; sampling and storage conditions (including stability tests); and cut-off reference values evaluation for different biological samples, such as whole blood, plasma, serum, urine, saliva, bile, vitreous humour and hair. This revision highlights the need of specific sampling care, storage conditions, and cut-off reference values interpretation in different biological samples, essential for proper practical application in forensic toxicology. Copyright © 2014 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  20. A comprehensive proteomics study on platelet concentrates: Platelet proteome, storage time and Mirasol pathogen reduction technology.

    Science.gov (United States)

    Salunkhe, Vishal; De Cuyper, Iris M; Papadopoulos, Petros; van der Meer, Pieter F; Daal, Brunette B; Villa-Fajardo, María; de Korte, Dirk; van den Berg, Timo K; Gutiérrez, Laura

    2018-03-19

    Platelet concentrates (PCs) represent a blood transfusion product with a major concern for safety as their storage temperature (20-24°C) allows bacterial growth, and their maximum storage time period (less than a week) precludes complete microbiological testing. Pathogen inactivation technologies (PITs) provide an additional layer of safety to the blood transfusion products from known and unknown pathogens such as bacteria, viruses, and parasites. In this context, PITs, such as Mirasol Pathogen Reduction Technology (PRT), have been developed and are implemented in many countries. However, several studies have shown in vitro that Mirasol PRT induces a certain level of platelet shape change, hyperactivation, basal degranulation, and increased oxidative damage during storage. It has been suggested that Mirasol PRT might accelerate what has been described as the platelet storage lesion (PSL), but supportive molecular signatures have not been obtained. We aimed at dissecting the influence of both variables, that is, Mirasol PRT and storage time, at the proteome level. We present comprehensive proteomics data analysis of Control PCs and PCs treated with Mirasol PRT at storage days 1, 2, 6, and 8. Our workflow was set to perform proteomics analysis using a gel-free and label-free quantification (LFQ) approach. Semi-quantification was based on LFQ signal intensities of identified proteins using MaxQuant/Perseus software platform. Data are available via ProteomeXchange with identifier PXD008119. We identified marginal differences between Mirasol PRT and Control PCs during storage. However, those significant changes at the proteome level were specifically related to the functional aspects previously described to affect platelets upon Mirasol PRT. In addition, the effect of Mirasol PRT on the platelet proteome appeared not to be exclusively due to an accelerated or enhanced PSL. In summary, semi-quantitative proteomics allows to discern between proteome changes due to

  1. Immunoreactive LH in long-term frozen human urine samples.

    Science.gov (United States)

    Singh, Gurmeet Kaur Surindar; Jimenez, Mark; Newman, Ron; Handelsman, David J

    2014-04-01

    Urine provides a convenient non-invasive alternative to blood sampling for measurement of certain hormones. Urinary luteinizing hormone (LH) measurements have been used for endocrinology research and anti-doping testing. However, the commercially available LH immunoassays are developed and validated for human blood samples but not urine so that LH assays intended for use with urine samples need thorough validation. Therefore, the present study evaluated the measurement of urinary LH immunoreactivity using previously validated immunofluorometric (IF) and immunochemiluminometric (ICL) LH assays after prolonged frozen storage. LH was measured in serial urine samples following administration of a single injection of one of two doses of recombinant human chorionic hormone (rhCG) with assays run at the end of study (2008) and again after four years of frozen (-20 °C) storage where samples were stored without adding preservatives. The ICL assay showed quantitatively reproducible LH measurements after prolonged -20 °C storage. However, the IF immunoassay gave consistently lower LH levels relative to ICL (2008) with a further proportionate reduction after four years of sample storage (2012). Yet, both the assays displayed similar patterns of the time-course of urine LH measurement both before and after four years of frozen storage. In conclusion, we found that both immunoassays are suitable for urinary LH measurements with ICL assay being more robust for quantitative urinary LH measurement such as for anti-doping purposes, whereas the IF could be applicable for research studies where urine LH levels are compared within-study but not in absolute terms. Copyright © 2013 John Wiley & Sons, Ltd.

  2. Changes in the carbohydrate and organic acid contents of tomatoes as a function of radiation dose and storage time

    International Nuclear Information System (INIS)

    Kovacs, E.

    1974-01-01

    Sugars and organic acids of tomatoes, variety Original Fruehrot, in different stages of development were examined by gas chromatography after silylation. Changes in the carbohydrate and organic acid content of half-ripe and ripe tomatoes were determined after treatment with different radiation doses (5, 15, 30, 60, 250 and 500 krad). Fructose, glucose, saccharose and malic acid could be detected in the tomato samples. The saccharose and malic acid contents of half-ripe tomatoes decreased as a result of irradiation with doses above 250 krad. In ripe tomatoes, the malic acid content fell most markedly under the influence of irradiation. The sugar content tended to decrease as a function of storage time, except for samples treated with 15 krad which usually delayed decomposition of the components tested. The effect of irradiation was more extensive in half-ripe tomatoes than in ripe ones. (F.J.)

  3. Development of Methodology and Field Deployable Sampling Tools for Spent Nuclear Fuel Interrogation in Liquid Storage

    International Nuclear Information System (INIS)

    Berry, T.; Milliken, C.; Martinez-Rodriguez, M.; Hathcock, D.; Heitkamp, M.

    2012-01-01

    This project developed methodology and field deployable tools (test kits) to analyze the chemical and microbiological condition of the fuel storage medium and determine the oxide thickness on the spent fuel basin materials. The overall objective of this project was to determine the amount of time fuel has spent in a storage basin to determine if the operation of the reactor and storage basin is consistent with safeguard declarations or expectations. This project developed and validated forensic tools that can be used to predict the age and condition of spent nuclear fuels stored in liquid basins based on key physical, chemical and microbiological basin characteristics. Key parameters were identified based on a literature review, the parameters were used to design test cells for corrosion analyses, tools were purchased to analyze the key parameters, and these were used to characterize an active spent fuel basin, the Savannah River Site (SRS) L-Area basin. The key parameters identified in the literature review included chloride concentration, conductivity, and total organic carbon level. Focus was also placed on aluminum based cladding because of their application to weapons production. The literature review was helpful in identifying important parameters, but relationships between these parameters and corrosion rates were not available. Bench scale test systems were designed, operated, harvested, and analyzed to determine corrosion relationships between water parameters and water conditions, chemistry and microbiological conditions. The data from the bench scale system indicated that corrosion rates were dependent on total organic carbon levels and chloride concentrations. The highest corrosion rates were observed in test cells amended with sediment, a large microbial inoculum and an organic carbon source. A complete characterization test kit was field tested to characterize the SRS L-Area spent fuel basin. The sampling kit consisted of a TOC analyzer, a YSI

  4. DEVELOPMENT OF METHODOLOGY AND FIELD DEPLOYABLE SAMPLING TOOLS FOR SPENT NUCLEAR FUEL INTERROGATION IN LIQUID STORAGE

    Energy Technology Data Exchange (ETDEWEB)

    Berry, T.; Milliken, C.; Martinez-Rodriguez, M.; Hathcock, D.; Heitkamp, M.

    2012-06-04

    This project developed methodology and field deployable tools (test kits) to analyze the chemical and microbiological condition of the fuel storage medium and determine the oxide thickness on the spent fuel basin materials. The overall objective of this project was to determine the amount of time fuel has spent in a storage basin to determine if the operation of the reactor and storage basin is consistent with safeguard declarations or expectations. This project developed and validated forensic tools that can be used to predict the age and condition of spent nuclear fuels stored in liquid basins based on key physical, chemical and microbiological basin characteristics. Key parameters were identified based on a literature review, the parameters were used to design test cells for corrosion analyses, tools were purchased to analyze the key parameters, and these were used to characterize an active spent fuel basin, the Savannah River Site (SRS) L-Area basin. The key parameters identified in the literature review included chloride concentration, conductivity, and total organic carbon level. Focus was also placed on aluminum based cladding because of their application to weapons production. The literature review was helpful in identifying important parameters, but relationships between these parameters and corrosion rates were not available. Bench scale test systems were designed, operated, harvested, and analyzed to determine corrosion relationships between water parameters and water conditions, chemistry and microbiological conditions. The data from the bench scale system indicated that corrosion rates were dependent on total organic carbon levels and chloride concentrations. The highest corrosion rates were observed in test cells amended with sediment, a large microbial inoculum and an organic carbon source. A complete characterization test kit was field tested to characterize the SRS L-Area spent fuel basin. The sampling kit consisted of a TOC analyzer, a YSI

  5. Optimal Real-Time Scheduling for Hybrid Energy Storage Systems and Wind Farms Based on Model Predictive Control

    Directory of Open Access Journals (Sweden)

    Meng Xiong

    2015-08-01

    Full Text Available Energy storage devices are expected to be more frequently implemented in wind farms in near future. In this paper, both pumped hydro and fly wheel storage systems are used to assist a wind farm to smooth the power fluctuations. Due to the significant difference in the response speeds of the two storages types, the wind farm coordination with two types of energy storage is a problem. This paper presents two methods for the coordination problem: a two-level hierarchical model predictive control (MPC method and a single-level MPC method. In the single-level MPC method, only one MPC controller coordinates the wind farm and the two storage systems to follow the grid scheduling. Alternatively, in the two-level MPC method, two MPC controllers are used to coordinate the wind farm and the two storage systems. The structure of two level MPC consists of outer level and inner level MPC. They run alternatively to perform real-time scheduling and then stop, thus obtaining long-term scheduling results and sending some results to the inner level as input. The single-level MPC method performs both long- and short-term scheduling tasks in each interval. The simulation results show that the methods proposed can improve the utilization of wind power and reduce wind power spillage. In addition, the single-level MPC and the two-level MPC are not interchangeable. The single-level MPC has the advantage of following the grid schedule while the two-level MPC can reduce the optimization time by 60%.

  6. Effect of gamma radiation and storage time on the volatile constituents, pirerine, piperettine and sensory quality of pepper

    Energy Technology Data Exchange (ETDEWEB)

    Bahari, I; Ishak, S; Ayub, M K [National Univ. of Malaysia, Bangi, Selangor

    1983-12-01

    The use of gamma radiation in prolonging the storage life of black and white peppers is promising. Doses up to 9 kGy and storage period up to 6 months did not significantly change (P<0.05) the volatile constituents of the peppers. Besides the increase in piperine content of unirradiated pepper there was no change in piperettine and piperine contents of both pepper with respect to increase in dose and storage time. No sensory change was detected for the treatments used (author).

  7. Accurate Sample Time Reconstruction of Inertial FIFO Data

    Directory of Open Access Journals (Sweden)

    Sebastian Stieber

    2017-12-01

    Full Text Available In the context of modern cyber-physical systems, the accuracy of underlying sensor data plays an increasingly important role in sensor data fusion and feature extraction. The raw events of multiple sensors have to be aligned in time to enable high quality sensor fusion results. However, the growing number of simultaneously connected sensor devices make the energy saving data acquisition and processing more and more difficult. Hence, most of the modern sensors offer a first-in-first-out (FIFO interface to store multiple data samples and to relax timing constraints, when handling multiple sensor devices. However, using the FIFO interface increases the negative influence of individual clock drifts—introduced by fabrication inaccuracies, temperature changes and wear-out effects—onto the sampling data reconstruction. Furthermore, additional timing offset errors due to communication and software latencies increases with a growing number of sensor devices. In this article, we present an approach for an accurate sample time reconstruction independent of the actual clock drift with the help of an internal sensor timer. Such timers are already available in modern sensors, manufactured in micro-electromechanical systems (MEMS technology. The presented approach focuses on calculating accurate time stamps using the sensor FIFO interface in a forward-only processing manner as a robust and energy saving solution. The proposed algorithm is able to lower the overall standard deviation of reconstructed sampling periods below 40 μ s, while run-time savings of up to 42% are achieved, compared to single sample acquisition.

  8. Synthesis of long live storage studies surface storage of MA-VL wastes

    International Nuclear Information System (INIS)

    Hollender, F.; Jourdain, F.; Piault, E.; Blanchet, Y.; Avakian, G.; Goger, F.; Caillaud, J.; Devictor, N.; Bary, B.; Moitier, C.; Breton, E.; Ranc, G.; Gaillard, J.P.; Lagrave, H.

    2004-01-01

    This document is realized in the framework of the axis 3 of the law of 1991 on the radioactive wastes management. It presents a long time surface storage installation of medium activity long life wastes. The long time of the installation would reach 300 years at the maximum. The feasibility is demonstrated and the design choices are presented and justified. The specific points of the long time storage installation, which are different from a classical industrial storage installation, are also discussed. (A.L.B.)

  9. Thermal energy storage devices, systems, and thermal energy storage device monitoring methods

    Science.gov (United States)

    Tugurlan, Maria; Tuffner, Francis K; Chassin, David P.

    2016-09-13

    Thermal energy storage devices, systems, and thermal energy storage device monitoring methods are described. According to one aspect, a thermal energy storage device includes a reservoir configured to hold a thermal energy storage medium, a temperature control system configured to adjust a temperature of the thermal energy storage medium, and a state observation system configured to provide information regarding an energy state of the thermal energy storage device at a plurality of different moments in time.

  10. Spent LWR fuel-storage costs

    International Nuclear Information System (INIS)

    Clark, H.J.

    1981-01-01

    Expanded use of existing storage basins is clearly the most economic solution to the spent fuel storage problem. The use of high-density racks followed by fuel disassembly and rod storage is an order of magnitude cheaper than building new facilities adjacent to the reactor. The choice of a new storage facility is not as obvious; however, if the timing of expenditures and risk allowance are to be considered, then modular concepts such as silos, drywells, and storage casks may cost less than water basins and air-cooled vaults. A comparison of the costs of the various storage techniques without allowances for timing or risk is shown. The impact of allowances for discounting and early resumption of reprocessing is also shown. Economics is not the only issue to be considered in selecting a storage facility. The licensing, environmental impact, timing, and social responses must also be considered. Each utility must assess all of these issues for their particular reactors before the best storage solution can be selected

  11. The effect of long-term storage on nanoleakage.

    Science.gov (United States)

    Li, H P; Burrow, M F; Tyas, M J

    2001-01-01

    To evaluate the durability of dentin bonding over time, the nanoleakage of four dentin bonding systems (Single Bond, Stae, Clearfil SE Bond and PermaQuik) over 24 hours, three months, six months and 12 months, was investigated. Flat occlusal dentin surfaces from extracted human molars were finished with wet 600-grit silicon carbide paper and bonded with one of the dentin bonding systems following manufacturers' instructions. The bonded surface was covered with < 1 mm thick layer of Silux Plus resin composite and light cured for 40 seconds. The specimens in each dentin-bonding group were randomly assigned to four sub-groups and kept in phosphate buffered saline solution (pH 7.4) containing 0.01% sodium azide at 37 degrees C for 24 hours, three, six or 12 months. The margins of all specimens were finished and polished with Sof-Lex disks after initial 24-hour storage. At the end of each storage time, the surrounding tooth surfaces except for 1 mm adjacent to the restoration were coated with nail varnish. The samples were immersed in a 50% w/v solution of silver nitrate for 24 hours, placed in photodeveloping solution and exposed to fluorescent light for eight hours. The samples were cut longitudinally and buccoligually, polished, mounted on stubs, carbon coated and observed in a Field Emission-SEM using backscattered electron mode. The results showed that systems using phosphoric acid as the etchant had a line of silver deposition at the base of the hybrid layer. Silver deposition increased in all systems over 12-months storage, with PermaQuik changing the least. Nanoleakage of the dentin bonding systems increased slightly during the 12-month storage period, indicating that they may be subject to hydrolytic attack over time.

  12. Influence of parasite density and sample storage time on the reliability of Entamoeba histolytica-specific PCR from formalin-fixed and paraffin-embedded tissues.

    Science.gov (United States)

    Frickmann, Hagen; Tenner-Racz, Klara; Eggert, Petra; Schwarz, Norbert G; Poppert, Sven; Tannich, Egbert; Hagen, Ralf M

    2013-12-01

    We report on the reliability of polymerase chain reaction (PCR) for the detection of Entamoeba histolytica from formalin-fixed, paraffin-embedded tissue in comparison with microscopy and have determined predictors that may influence PCR results. E. histolytica-specific and Entamoeba dispar-specific real-time PCR and microscopy from adjacent histologic sections were performed using a collection of formalin-fixed, paraffin-embedded tissue specimens obtained from patients with invasive amebiasis. Specimens had been collected during the previous 4 decades. Association of sample age, parasite density, and reliability of PCR was analyzed. E. histolytica PCR was positive in 20 of 34 biopsies (58.8%); 2 of these 20 were microscopically negative for amebae in neighboring tissue sections. PCR was negative in 9 samples with visible amebae in neighboring sections and in 5 samples without visible parasites in neighboring sections. PCR was negative in all specimens that were older than 3 decades. Low parasite counts and sample ages older than 20 years were predictors for false-negative PCR results. All samples were negative for E. dispar DNA. PCR is suitable for the detection of E. histolytica in formalin-fixed, paraffin-embedded tissue samples that are younger than 2 decades and that contain intermediate to high parasite numbers. Negative results in older samples were due to progressive degradation of DNA over time as indicated by control PCRs targeting the human 18S rRNA gene. Moreover, our findings support previous suggestions that only E. histolytica but not E. dispar is responsible for invasive amebiasis.

  13. Effects of Extended Freezer Storage on the Integrity of Human Milk.

    Science.gov (United States)

    Ahrabi, Ali Faraghi; Handa, Deepali; Codipilly, Champa N; Shah, Syed; Williams, Janet E; McGuire, Mark A; Potak, Debra; Aharon, Grace Golda; Schanler, Richard J

    2016-10-01

    To examine the integrity (pH, bacterial counts, host defense factors, nutrient contents, and osmolality) of freshly expressed and previously refrigerated human milk subjected to long-term freezer storage. Mothers donated 100 mL of freshly expressed milk. Samples were divided into baseline, storage at -20°C (fresh frozen) for 1, 3, 6, and 9 months, and prior storage at +4°C for 72 hours (refrigerated frozen) before storage at -20°C for 1 to 9 months. Samples were analyzed for pH, total bacterial colony count, gram-positive and gram-negative colony counts, and concentrations of total protein, fat, nonesterified fatty acids, lactoferrin, secretory IgA, and osmolality. Milk pH, total bacterial colony count, and Gram-positive colony counts decreased significantly with freezer storage (P negative colony count decreased significantly over time (P human milk for 9 months at -20°C is associated with decreasing pH and bacterial counts, but preservation of key macronutrients and immunoactive components, with or without prior refrigeration for 72 hours. These data support current guidelines for freezer storage of human milk for up to 9 months for both freshly expressed and refrigerated milk. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Conservation of strawberries (fragaria vesca l.) by gamma radiation storaged by refrigeration

    International Nuclear Information System (INIS)

    Paredes R, D.A.

    1995-01-01

    Fresh strawberries were irradiated with gamma radiation. The optimum dose of irradiation, chemical, microbiological, and sensorial stability of treated product and the conservation time of product during its storage were determined. Dosimetry was calculated according to standardized ASTM method 'Fricke'. Conditioned and pocket in semipermeable polyethylene pocket samples were exposed to 1,0, 2,0, and 3.0 kGy irradiation dose in a gamma-cell irradiator using 60 Co as source. Samples-witness (unirradiated) were prepared with comparatives purpose. Irradiated products and samples were storaged at 5 0 C - 10 0 C temperature, with 90% relative humidity. The physical-organoleptic, chemical-bromatologic and microbiological controls of products were carried out each 7 days. The optimum parameter of irradiation process was 2,0 kGy/h, dose that kept the product in good conditions until 23 days after treatment, storaged at 5 0 C to 10 0 C and 90% relative humidity while alterations in samples-witness were evident from the 5 th day of storage. The irradiated product did not suffer any important loss of its nutritional value; it increased its content of soluble solids and showed less tendency to humidity, organic acids and specially vitamin C diminution. (author). 49 refs.,11 tabs.; 6 figs

  15. Optimal time points sampling in pathway modelling.

    Science.gov (United States)

    Hu, Shiyan

    2004-01-01

    Modelling cellular dynamics based on experimental data is at the heart of system biology. Considerable progress has been made to dynamic pathway modelling as well as the related parameter estimation. However, few of them gives consideration for the issue of optimal sampling time selection for parameter estimation. Time course experiments in molecular biology rarely produce large and accurate data sets and the experiments involved are usually time consuming and expensive. Therefore, to approximate parameters for models with only few available sampling data is of significant practical value. For signal transduction, the sampling intervals are usually not evenly distributed and are based on heuristics. In the paper, we investigate an approach to guide the process of selecting time points in an optimal way to minimize the variance of parameter estimates. In the method, we first formulate the problem to a nonlinear constrained optimization problem by maximum likelihood estimation. We then modify and apply a quantum-inspired evolutionary algorithm, which combines the advantages of both quantum computing and evolutionary computing, to solve the optimization problem. The new algorithm does not suffer from the morass of selecting good initial values and being stuck into local optimum as usually accompanied with the conventional numerical optimization techniques. The simulation results indicate the soundness of the new method.

  16. Analysis of Samples Collected from the Surface of Interim Storage Canisters at Calvert Cliffs in June 2017: Revision 01.

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Charles R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schindelholz, Eric John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-11-01

    In June 2017, dust and salt samples were collected from the surface of Spent Nuclear Fuel (SNF) dry storage canisters at the Calvert Cliffs Nuclear Power Plant. The samples were delivered to Sandia National laboratories for analysis. Two types of samples were collected: filter-backed Scotch-Brite TM pads were used to collect dry dust samples for characterization of salt and dust morphologies and distributions; and Saltsmart TM test strips were used to collect soluble salts for determining salt surface loadings per unit area. After collection, the samples were sealed into plastic sleeves for shipping. Condensation within the sleeves containing the Scotch-Brite TM samples remobilized the salts, rendering them ineffective for the intended purpose, and also led to mold growth, further compromising the samples; for these reasons, the samples were not analyzed. The SaltSmart TM samples were unaffected and were analyzed by ion chromatography for major anions and cations. The results of those analyses are presented here.

  17. Effect of storage time on microbial quality of some spices and dried seasonings

    International Nuclear Information System (INIS)

    Adu-Gyamfi, A.

    2006-01-01

    The effect of storage time on the microbial quality of some spices and dried seasonings (SOS) (dawadawa, pepper, ginger, shrimp and fish powders) was studied over a 12-month period. Microbial load and profile of irradiated and unirradiated SOS were assessed at 0, 6 and 12-month periods. The range of total variable counts (TVCs) were initially determined at 0.81-4.53 and 4.658.51 log 10 cfu g -1 for irradiated and un irradiated SDS, respectively; those for mould and yeast counts (MYCs) were determined at 0-1.74 and 1.55-3.35 log 10 cfu g -1 , respectively. Generally, TVCs were not significantly affected (P<0.05) by the 6 and 12-month periods, but MYCs were significantly reduced (P<0.05) after the storage periods in some SDS. Microbial profile, mainly dominated by Bacillus spp., Laclobacillus spp., Clostridium spp., Aspergillus spp. and Penicillium spp., was stable after the 6 and 12-month periods for all the SDS. However, the profile was consistently more diverse on dawadawa. pepper and ginger powders. No adverse change in microbial quality of irradiated and unirradiated SDS was observed at the end of the storage periods

  18. Effects of red blood cell storage time on transfused patients in the ICU-protocol for a systematic review

    DEFF Research Database (Denmark)

    Rygård, S L; Jonsson, A B; Madsen, M B

    2017-01-01

    BACKGROUND: Patients in the intensive care unit (ICU) are often anaemic due to blood loss, impaired red blood cell (RBC) production and increased RBC destruction. In some studies, more than half of the patients were treated with RBC transfusion. During storage, the RBC and the storage medium...... evidence to assess the effects of shorter vs. longer storage time of transfused RBCs for ICU patients. METHODS: We will conduct a systematic review with meta-analyses and trial sequential analyses of randomised clinical trials, and also include results of severe adverse events from large observational...

  19. Influence of alginate impression materials and storage time on surface detail reproduction and dimensional accuracy of stone models.

    Science.gov (United States)

    Guiraldo, Ricardo D; Moreti, Ana F F; Martinelli, Julia; Berger, Sandrine B; Meneghel, Luciana L; Caixeta, Rodrigo V; Sinhoreti, Mário A C

    2015-01-01

    This study compared the surface detail reproduction and dimensional accuracy of stone models obtained from molds prepared using different alginate impression materials (Cavex ColorChange, Hydrogum 5, or Jeltrate Plus) and with different storage times (1, 3, and 5 days) to models from molds that were filled immediately with no storage time. The molds were prepared over a matrix containing 50-μm line, (ISO 1563 standard) under pressure with a perforated metal tray. The molds were removed 2 minutes after loss of sticky consistency and either filled immediately or stored in closed jars at 100% relative humidity and 37°C for 1, 3, or 5 days. The molds were filled with dental plaster (Durone IV). Surface detail reproduction and dimensional accuracy were evaluated using optical microscopy on the 50-μm wide line, which was 25 mm in length, according to ISO 1563 standard. The dimensional accuracy results (%) were subjected to analysis of variance. The 50-μm wide line (ISO 1563 standard) was completely reproduced by all alginate impression materials regardless of the storage time. There was no statistically significant difference in the mean dimensional accuracy values of stone models made from molds composed of different alginate impression materials and with different storage times (p = 0.989). In conclusion, storing the mold for five days prior to filling did not change the surface detail reproduction or dimensional accuracy of the alginates examined in this study.

  20. High temperature, short time pasteurization temperatures inversely affect bacterial numbers during refrigerated storage of pasteurized fluid milk.

    Science.gov (United States)

    Ranieri, M L; Huck, J R; Sonnen, M; Barbano, D M; Boor, K J

    2009-10-01

    The grade A Pasteurized Milk Ordinance specifies minimum processing conditions of 72 degrees C for at least 15 s for high temperature, short time (HTST) pasteurized milk products. Currently, many US milk-processing plants exceed these minimum requirements for fluid milk products. To test the effect of pasteurization temperatures on bacterial numbers in HTST pasteurized milk, 2% fat raw milk was heated to 60 degrees C, homogenized, and treated for 25 s at 1 of 4 different temperatures (72.9, 77.2, 79.9, or 85.2 degrees C) and then held at 6 degrees C for 21 d. Aerobic plate counts were monitored in pasteurized milk samples at d 1, 7, 14, and 21 postprocessing. Bacterial numbers in milk processed at 72.9 degrees C were lower than in milk processed at 85.2 degrees C on each sampling day, indicating that HTST fluid milk-processing temperatures significantly affected bacterial numbers in fluid milk. To assess the microbial ecology of the different milk samples during refrigerated storage, a total of 490 psychrotolerant endospore-forming bacteria were identified using DNA sequence-based subtyping methods. Regardless of processing temperature, >85% of the isolates characterized at d 0, 1, and 7 postprocessing were of the genus Bacillus, whereas more than 92% of isolates characterized at d 14 and 21 postprocessing were of the genus Paenibacillus, indicating that the predominant genera present in HTST-processed milk shifted from Bacillus spp. to Paenibacillus spp. during refrigerated storage. In summary, 1) HTST processing temperatures affected bacterial numbers in refrigerated milk, with higher bacterial numbers in milk processed at higher temperatures; 2) no significant association was observed between genus isolated and pasteurization temperature, suggesting that the genera were not differentially affected by the different processing temperatures; and 3) although typically present at low numbers in raw milk, Paenibacillus spp. are capable of growing to numbers that can

  1. Effect of Storage Time and Temperature on Dimensional Stability of Impressions Made with Zinc Oxide Impression Paste

    Directory of Open Access Journals (Sweden)

    Sareh Habibzadeh

    2016-10-01

    Full Text Available Objectives: This study aimed to assess the effect of storage time and temperature on dimensional stability of impressions made with Cavex Outline zinc oxide impression paste.Materials and Methods: A round stainless steel mold with five grooves (three horizontal and two vertical was used in this in-vitro experimental study. Cavex Outline impression paste was prepared according to the manufacturer’s instructions and applied to the mold. The mold was placed on a block and stored at 35°C and 100% humidity for setting. The impressions were poured with stone immediately and also after 30, 120, 240 and 420 minutes and 24 hours. The distance between the vertical lines on the casts was measured and compared with that in the immediately poured cast.Results: Storage in a refrigerator and at room temperature for zero to seven hours had no significant effect on dimensional stability of the impressions; however, 24 hours of storage in a refrigerator or at room temperature decreased the dimensional stability of Cavex Outline (P=0.001. Also, a significant association was found between dimensional changes following 24 hours of storage in a refrigerator (4°C and at room temperature (23°C; P<0.01.Conclusions: The optimal pouring time of Cavex Outline impressions with stone is between zero to seven hours, and 24 hours of storage significantly decreases the dimensional stability.Keywords: Dental Impression Materials; Zinc Oxide; Cavex

  2. Digital timing: sampling frequency, anti-aliasing filter and signal interpolation filter dependence on timing resolution

    International Nuclear Information System (INIS)

    Cho, Sanghee; Grazioso, Ron; Zhang Nan; Aykac, Mehmet; Schmand, Matthias

    2011-01-01

    The main focus of our study is to investigate how the performance of digital timing methods is affected by sampling rate, anti-aliasing and signal interpolation filters. We used the Nyquist sampling theorem to address some basic questions such as what will be the minimum sampling frequencies? How accurate will the signal interpolation be? How do we validate the timing measurements? The preferred sampling rate would be as low as possible, considering the high cost and power consumption of high-speed analog-to-digital converters. However, when the sampling rate is too low, due to the aliasing effect, some artifacts are produced in the timing resolution estimations; the shape of the timing profile is distorted and the FWHM values of the profile fluctuate as the source location changes. Anti-aliasing filters are required in this case to avoid the artifacts, but the timing is degraded as a result. When the sampling rate is marginally over the Nyquist rate, a proper signal interpolation is important. A sharp roll-off (higher order) filter is required to separate the baseband signal from its replicates to avoid the aliasing, but in return the computation will be higher. We demonstrated the analysis through a digital timing study using fast LSO scintillation crystals as used in time-of-flight PET scanners. From the study, we observed that there is no significant timing resolution degradation down to 1.3 Ghz sampling frequency, and the computation requirement for the signal interpolation is reasonably low. A so-called sliding test is proposed as a validation tool checking constant timing resolution behavior of a given timing pick-off method regardless of the source location change. Lastly, the performance comparison for several digital timing methods is also shown.

  3. Characterization of Tifton 85 bermudagrass haylage with different layers of polyethylene film and storage time.

    Science.gov (United States)

    Nath, Caroline Daiane; Neres, Marcela Abbado; Scheidt, Kácia Carine; Bersot, Luciano Dos Santos; Sunahara, Samantha Mariana Monteiro; Sarto, Jaqueline Rocha Wobeto; Stangarlin, José Renato; Gomes, Simone Damasceno; Sereno, Mallu Jagnow; Perin, Ana Paula

    2018-03-02

    The objective was to characterize the fermentative and microbiological profile of Tifton 85 bermudagrass haylage with different layers of polyethylene film and storage time. The experimental design consisted of a randomized block design with four and six wrapping layers (100 and 150 microns in total. respectively) allocated in the main plots, through repeated measures analysis (30, 60, and 90 days of storage) with four replicates. The storage time and number of wrapping layers did not show changes in the population of Clostridium and lactic acid bacteria. A decrease was observed in the enterobacteria population with an increase in the storage period in the two wrapping layers studied. Upon opening of the haylage at 30 days, the population of Bacillus was lower in haylages made with six layers of wrapping (3.63 log colony forming units (CFU) g-1). No growth of Listeria sp. or Salmonella sp. was observed during the experimental period. The fungal genera with greater occurrence were Penicillium sp. and Fusarium sp. The following mycotoxins were not detected: ochratoxin A, fumonisins, and zearalenone. Relative to the organic butyric, propionic, and acetic acids, the haylages presented a low concentration of lactic acid; this may have prevented a drop in the pH, which was high when the silos were opened (5.4). The levels of ammoniacal nitrogen and soluble carbohydrates presented no variation among the number of wrapping layers, with an overall average of 35.55 and 38.04 g kg-1. Tifton 85 bermudagrass haylage wrapped with four and six layers presented adequate fermentation and microbiological characteristics in the evaluated periods.

  4. Sampling the contents of High-Level Waste tanks

    International Nuclear Information System (INIS)

    Gray, P.L.; Skidmore, V.L.; Bragg, T.K.; Kerrigan, T.

    1993-01-01

    Samples were recently retrieved from a HLW storage tank at the DOE Savannah River Site using simple tools developed for this task. The tools are inexpensive and manually operated, require brief tank open times, and minimize radiation doses

  5. Investigation of physical detection markers in irradiated foods under different radiation sources and post-irradiation storage conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Joong Ho; Kim, Gui Ran; Ahn, Jae Jun; Kim, Dong Gil; Jin, Qiong Wen; Park, Ju Hwan; Lee, Ji Hyun [Kyungpook National University, Daegu (Korea, Republic of)

    2010-04-15

    In PSL analysis, all unirradiated samples showed less than 700 (negative) photon counts (PCs). At 5 kGy, spice samples showed PCs in range of 700-5,000 (intermediate), while grains, legumes, root-crops, and seasonings samples showed PCs over 5,000 (positive). This PSL based-detection of radiation treatment was possible even after 24 months of storage. In TL analysis, TL glow curve was characteristically different between unirradiated and irradiated samples. Glow curves were observed in temperature ranges of 150-250 .deg. C for irradiated and over 300 .deg. C for unirradiated samples. TL ratio (TL{sub 1}/TL{sub 2}) provided valuable additional confirmations as unirradiated sample showed values less than 0.1, while irradiated sample showed more than 0.1. However, with storage time, TL intensity and TL ratio decreased but discrimination was still possible even after storage of 24 months. Samples stored at room temperature with exposure to direct or indirect light enhanced the mentioned decrease of TL intensity and TL ratio as compared to low temperature storage in dark room. In ESR analysis, legumes and spices showed radiation-induced cellulose radicals, while seasonings showed multi-component signals of radiation-induced crystalline sugar radical. These radiation-induced radicals could be potential markers for the detection of radiation treatments in subjected samples. The decreasing trend was also found for radiation-specific ESR signals of cellulose and crystalline sugar radicals during storage. However, radiation-induced radicals in legumes, powdered pepper and seasonings were detectable even after 6 months of storage

  6. Adaptive Sampling of Time Series During Remote Exploration

    Science.gov (United States)

    Thompson, David R.

    2012-01-01

    This work deals with the challenge of online adaptive data collection in a time series. A remote sensor or explorer agent adapts its rate of data collection in order to track anomalous events while obeying constraints on time and power. This problem is challenging because the agent has limited visibility (all its datapoints lie in the past) and limited control (it can only decide when to collect its next datapoint). This problem is treated from an information-theoretic perspective, fitting a probabilistic model to collected data and optimizing the future sampling strategy to maximize information gain. The performance characteristics of stationary and nonstationary Gaussian process models are compared. Self-throttling sensors could benefit environmental sensor networks and monitoring as well as robotic exploration. Explorer agents can improve performance by adjusting their data collection rate, preserving scarce power or bandwidth resources during uninteresting times while fully covering anomalous events of interest. For example, a remote earthquake sensor could conserve power by limiting its measurements during normal conditions and increasing its cadence during rare earthquake events. A similar capability could improve sensor platforms traversing a fixed trajectory, such as an exploration rover transect or a deep space flyby. These agents can adapt observation times to improve sample coverage during moments of rapid change. An adaptive sampling approach couples sensor autonomy, instrument interpretation, and sampling. The challenge is addressed as an active learning problem, which already has extensive theoretical treatment in the statistics and machine learning literature. A statistical Gaussian process (GP) model is employed to guide sample decisions that maximize information gain. Nonsta tion - ary (e.g., time-varying) covariance relationships permit the system to represent and track local anomalies, in contrast with current GP approaches. Most common GP models

  7. Effect of curd freezing and packaging methods on the organic acid contents of goat cheeses during storage

    Directory of Open Access Journals (Sweden)

    Pınar Balkir

    2011-09-01

    Full Text Available Effects of freezing and packaging methods on organic acid content of goat cheese during 12 weeks of storage were determined. Goat cheese milk curds were divided into two batches; one of the batches was directly processed in to goat cheese while the other was frozen at -18 °C and stored for six months and processed into cheese after being thawed. Cheese samples were packed in three parts and stored at 4 °C refrigerated control sample and at -18 °C for six months frozen experimental samples. Cheese samples were packed in three different packaging methods: aerobic, vacuum or modified atmosphere. Citric, malic, fumaric, acetic, lactic, pyruvic and propionic acids were analyzed using HPLC method after 1st, 3rd, 6th, 9th and 12th week of storage period. Lactic acid was the main organic acids while pyruvic acid had the lowest content in all cheese samples. Citric and fumaric acid levels of frozen samples increased during storage whereas malic, acetic, pyruvic and propionic acid amounts were decreased compared to the beginning of storage. Packaging methods and freezing process also effected lactic acid levels statistically (p<0.05. Fumaric, acetic and lactic acid concentration of refrigerated samples were increased but citric, malic and propionic acids decreased during storage. Pyruvic acid level did not change significantly. It was determined that organic acid concentrations were effected by freezing process, storage time and packaging methods significantly (p<0.05.

  8. Assessment of frozen storage duration effect on quality characteristics of various horse muscles

    Directory of Open Access Journals (Sweden)

    Pil Nam Seong

    2017-12-01

    Full Text Available Objective The study aimed at assessing the effects of frozen storage duration on quality characteristics, lipid oxidation and sensory quality of various horse muscles. Methods Five representative muscles: longissimus dorsi (LD, gluteus medius (GM, semimembranosus (SM, biceps femoris (BF, and triceps brachii (TB at 24 h post-mortem obtained from 28-mo-old Jeju female breed horses (n = 8 were used in the present investigation. The muscles were vacuum-packaged and frozen at −20°C for 120, 240, and 360 days. All the samples were analyzed for thawing and cooking losses, pH, Warner–Bratzler shear forces (WBSF, color traits, total volatile basic nitrogen (TVBN, thiobarbituric acid reactive substances (TBARS and sensory traits. The muscle samples analyzed on day 0 of frozen storage (fresh, non-frozen were used for comparison. Results Results revealed that thawing and cooking losses significantly (p<0.05 increased in all the muscles after 120 days and then remained unchanged up to 360 days of frozen storage. The TBARS and TVBN contents significantly increased as increasing frozen storage time up to 360 days (p<0.05. While, significant decreases in WBSF values were observed for all the muscles with increased frozen storage time (p<0.05. Frozen storage variously affected the color traits of the muscles for instance; the redness of LD, GM, and BF muscles showed a decreasing tendency during frozen storage while it was not changed in TB and SM muscles. Furthermore, the frozen storage did not produce detrimental effects on sensory quality as it did not cause flavor and juiciness defects whereas it partially improved the tenderness of all the muscles studied. Conclusion Based on the results obtained from our work, it is concluded that frozen storage could be applied to increase the long-term shelf life of horsemeat while still retaining its sensory quality.

  9. Stability of flavoured phytosterol-enriched drinking yogurts during storage as affected by different packaging materials.

    Science.gov (United States)

    Semeniuc, Cristina Anamaria; Cardenia, Vladimiro; Mandrioli, Mara; Muste, Sevastiţa; Borsari, Andrea; Rodriguez-Estrada, Maria Teresa

    2016-06-01

    The aim of this study was to investigate the influence of different packaging materials on storage stability of flavoured phytosterol-enriched drinking yogurts. White vanilla (WV) and blood orange (BO) phytosterol-enriched drinking yogurts conditioned in mono-layer and triple-layer co-extruded plastic bottles were stored at +6 ± 1 °C for 35 days (under alternating 12 h light and 12 h darkness) to simulate shelf-life conditions. Samples were collected at three different storage times and subjected to determination of total sterol content (TSC), peroxide value (PV) and thiobarbituric acid reactive substances (TBARs). TSC was not significantly affected by packaging material or storage time and met the quantity declared on the label. PV was significantly influenced by yogurt type × packaging material × storage time interaction and TBARs by packaging material × storage time interaction. Between the two packaging materials, the triple-layer plastic mini bottle with black coloured and completely opaque intermediate layer offered the best protection against lipid oxidation. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.

  10. The effect of gamma radiation and storage time on the volatile constituents, pirerine, piperettine and sensory quality of pepper

    International Nuclear Information System (INIS)

    Bahari, I.; Ishak, S.; Ayub, M.K.

    1983-01-01

    The use of gamma radiation in prolonging the storage life of black and white peppers is promising. Doses up to 9 kGy and storage period up to 6 months did not significantly change (P<0.05) the volatile constituents of the peppers. Besides the increase in piperine content of unirradiated pepper there was no change in piperettine and piperine contents of both pepper with respect to increase in dose and storage time. No sensory change was detected for the treatments used (author)

  11. Keeping carrots quality during storage by irradiation

    International Nuclear Information System (INIS)

    El-Nashaby, F.M.; Hafez, S.A.

    2000-01-01

    Fresh carrots were gamma irradiated at 0, 0.1, 0.2, 0.5 and 1.0 KGy doses using cobalt-60 source. A portion of the irradiated carrots was stored at ambient temperature (20-25 degree C) and the rest was packed in polyethylene bags and stored in refrigerator temperature (5± 1 degree C). The results indicated that the sprouting of carrots were completely inhibited by radiation dose of 0.2 KGy either at ambient temperature or cold storage, while the non-irradiated samples started to sprout after 2 and 4 weeks of storage at ambient temperature and cold storage respectively. Furthermore, samples treated with gamma rays showed lower values of weight loss compared to the untreated ones during storage. Concerning storage temperature, it was found that the rate of weight loss during storage was higher at ambient temperature than in refrigerator. Micro-organisms were greatly affected by gamma rays, their counts were found to be decreased by increasing irradiation dose as compared with the control sample. Moreover, during storage period, refrigerated samples showed lower bacterial and molds counts than samples stored at ambient temperature. On the other hand, it was also observed that irradiated samples at the higher dose i.e. 1.0 KGy stored either at ambient temperature or in refrigerator showed higher bacterial and molds counts than unirradiated ones. The lowest dose (0.1 KGy) had no effect on carotene and sugars contents of carrots while increasing the dose above 0.2 KGy led to gradual decrease in carotene contents and gradual increase in total soluble sugars contents of the samples with increasing the irradiation dose compared with the nonirradiated ones. The results proved that gamma irradiation dose of 0.2 Gy was effective for sprout inhibition of carrots and increase their shelf-life to 10 weeks at ambient temperature without adverse effects on carotene and sugars contents of treated carrots

  12. Cytochrome oxidase as an indicator of ice storage and frozen storage

    DEFF Research Database (Denmark)

    Godiksen, Helene; Jessen, Flemming

    2001-01-01

    in different cods was 21%, and the coefficient of variation of different analyses on the same homogenate was 5%. It was shown that ice storage of muscle samples before they were frozen and thawed resulted in a major freezing-induced activation of cytochrome oxidase activity. The enzyme may therefore be used...... as an indicator of frozen fish to determine if the fish has been stored on ice before freezing. Cytochrome oxidase activity showed also potential as an indicator of frozen storage, as it was possible to distinguish between the frozen storage temperatures -9, -20, and -40 degreesC....

  13. Effect of storage of shelled Moringa oleifera seeds from reaping time on turbidity removal.

    Science.gov (United States)

    Golestanbagh, M; Ahamad, I S; Idris, A; Yunus, R

    2011-09-01

    Moringa oleifera is an indigenous plant to Malaysia whose seeds are used for water purification. Many studies on Moringa oleifera have shown that it is highly effective as a natural coagulant for turbidity removal. In this study, two different methods for extraction of Moringa's active ingredient were investigated. Results of sodium chloride (NaCl) and distilled water extraction of Moringa oleifera seeds showed that salt solution extraction was more efficient than distilled water in extracting Moringa's active coagulant ingredient. The optimum dosage of shelled Moringa oleifera seeds extracted by the NaCl solution was comparable with that of the conventional chemical coagulant alum. Moreover, the turbidity removal efficiency was investigated for shelled Moringa oleifera seeds before drying in the oven under different storage conditions (i.e. open and closed containers at room temperature, 27 °C) and durations (fresh, and storage for 2, 4, 6 and 8 weeks from the time the seeds were picked from the trees). Our results indicate that there are no significant differences in coagulation efficiencies and, accordingly, turbidity removals between the examined storage conditions and periods.

  14. Evaluation of the Effect of Storage Temperature, Atmosphere and Packaging Materials on Some Properties of Carum copticum Fruits during Nine Months Storage

    Directory of Open Access Journals (Sweden)

    gonai baghdadi

    2018-03-01

    (at four levels: 0, 3, 6 and 9 months as sub plots were considered. Seed samples were taken randomly from each package at four times period. Essential oil percentage, seed weight, gas composition in packages with modified atmosphere and seed germination factors (seed germination percentage (SGP, germination rate (GR, mean germination time (MGT, and germination Index (GI were evaluated during this nine months Storage. Results and Discussion: The highest weight loss was 2/43% in the paper bags stored at 30°C at the fourth to sixth months especially in the fifth month. Aluminum foil package under vacuum condition stored at 30°C had the lowest weight and minimum weight changes during nine months of storage, so it was the best packages compared to others. The results show that Polyethylene-polyamide packages and Aluminum foil packages under vacuum condition are almost impermeable to air and moisture. Increasing weight at 20°C may be due to accumulation of water vapor from the respiration during early period of storage. Seed germination test provides an indication about seedling vigor as well as performance of seed in the field. In most cases, performance relates to the ability of seeds to germinate and produce a seedling that will emerge from the soil and development into a healthy vigorous plant. Packages with different combinations of gas (2% and 10% oxygen at 30°C,aluminum foil under vacuum condition and Polyethylene-polyamide packages with a gas composition of [98%N2 + 2%O2] at 20°C were packages with higher germination percentage after nine months storage. Based on this results, it appears that packaging materials and storage temperature did not show any significant difference on essential oil percentage and further changes in the amount of oil related to duration of storage. Kumar et al. (2013 showed that the essential oil content and composition were affected by harvest time and storage conditions. Kazaz et al. (2009 investigated the effect of different storage

  15. Investigation of rheological properties of winter wheat varieties during storage

    Directory of Open Access Journals (Sweden)

    Móré M.

    2015-01-01

    Full Text Available The paper shows the results of some experimental researches on the rheological characteristics of the dough obtained from the flour of three winter wheat varieties. We used valorigraph test to determine the rheological properties of wheat flour dough, because it determines the quality of the end-products. Winter wheat varieties (Lupus, Mv Toldi and GK Csillag were produced and their samples were collected on Látókép Research Farm of the University of Debrecen in the crop year of 2011/2012. We have carried out a short-term storage experiment (from July to August, 2012. We analysed the changes in water absorption capacity, dough stability time and valorigraph quality number for 3 times (24.07.2012, 31.07.2012, 21.08.2012 during short-term storage. Our results showed that the baking quality of Lupus, Mv Toldi and GK Csillag improved during the storage period.

  16. Hydrogen storage in carbon nanostruc

    NARCIS (Netherlands)

    Hirscher, M.; Becher, M.; Haluska, M.; Quintel, A.; Skakalova, V.; Choi, M.; Dettlaff-Weglikowska, U.; Roth, S.; Stepanek, I.; Bernier, P.; Leonhardt, A.; Fink, J.

    2002-01-01

    The paper gives a critical review of the literature on hydrogen storage in carbon nanostructures. Furthermore, the hydrogen storage of graphite, graphite nanofibers (GNFs), and single-walled carbon nanotubes (SWNTs) was measured by thermal desorption spectroscopy (TDS). The samples were ball milled

  17. Changes in the content of water-soluble vitamins in Actinidia chinensis during cold storage

    Directory of Open Access Journals (Sweden)

    Zhu Xian-Bo

    2016-01-01

    Full Text Available We assessed the effects of cold storage on nine water-soluble vitamins in 7 cultivars of Actinidia chinensis (kiwifruit using high-performance liquid chromatography. Samples were collected at three time points during cold storage: one day, 30 days, and when edible. We found that vitamin C in most cultivars was raised with cold storage, but there was no consistent increased or decreased trend for other water-soluble vitamins across cultivars in storage. After one day of cold storage, vitamins B1 and B2 were the most prevalent vitamins in Control (wild fruit, while vitamins B5 and B6 were most prevalent in the Hongyang and Qihong cultivars. However, B12 was the most prevalent vitamin in the Qihong cultivar after 30 days of cold storage. Vitamins B3, B7, B9, and C were detected at the edible time point in Huayou, Hongyang, Jinnong-2, and Control fruit. Vitamin contents varied significantly among cultivars of kiwifruit following different durations of cold storage. Out of the three durations tested, a period of 30 days in cold storage was the most suitable for the absorption of water-soluble vitamins by A. chinensis.

  18. Effect of Pouring Time and Storage Temperature on Dimensional Stability of Casts Made from Irreversible Hydrocolloid

    Directory of Open Access Journals (Sweden)

    M. Farzin

    2010-12-01

    Full Text Available Objective: The aim of this study was to evaluate the dimensional stability of casts made from an alginate impression material poured immediately and stored after specific periods.Materials and Methods: The common alginate used in Iran (Super; Iralgin, Golchai Co.,Tehran, Iran was tested. A master model was mounted on a special device and used to obtain the impressions. These impressions were stored at 23°C (SD=1 and 4°C (SD=1 in100% relative humidity, then poured with gypsum immediately and again after 12, 25, 45 and 60 minutes. The casts were measured with a traveling microscope with the precision of 0.5 micrometer.Results: The dimensional stability of the alginate and impressions were both significantly time and temperature dependent. The impressions were dimensionally stable significantly until 12 minutes of storage at room temperature and until 45 minutes of storage at 4°C(SD=1.Conclusion: The dimensional stability of the alginate impressions was influenced by the storage time and environment temperature, but a humid environment and 4°C (SD=1temperature may delay the pouring.

  19. Liquid chromatography and ultra-performance liquid chromatography-mass spectrometry fingerprinting of human urine: sample stability under different handling and storage conditions for metabonomics studies.

    Science.gov (United States)

    Gika, Helen G; Theodoridis, Georgios A; Wilson, Ian D

    2008-05-02

    Typically following collection biological samples are kept in a freezer for periods ranging from a few days to several months before analysis. Experience has shown that in LC-MS-based metabonomics research the best analytical practice is to store samples as these are collected, complete the sample set and analyse it in a single run. However, this approach is prudent only if the samples stored in the refrigerator or in the freezer are stable. Another important issue is the stability of the samples following the freeze-thaw process. To investigate these matters urine samples were collected from 6 male volunteers and analysed by LC-MS and ultra-performance liquid chromatography (UPLC)-MS [in both positive and negative electrospray ionization (ESI)] on the day of collection or at intervals of up to 6 months storage at -20 degrees C and -80 degrees C. Other sets of these samples underwent a series of up to nine freeze-thaw cycles. The stability of samples kept at 4 degrees C in an autosampler for up to 6 days was also assessed, with clear differences appearing after 48h. Data was analysed using multivariate statistical analysis (principal component analysis). The results show that sample storage at both -20 and -80 degrees C appeared to ensure sample stability. Similarly up to nine freeze thaw cycles were without any apparent effect on the profile.

  20. Bacteriological quality of raw human milk: effect of storage in a refrigerator.

    Science.gov (United States)

    Olowe, S A; Ahmed, I; Lawal, S F; Ransome-Kuti, S

    1987-12-01

    Eighty-seven breast milk samples were obtained from 63 mothers of infants on the neonatal intensive care unit of the Lagos University Teaching Hospital. The samples were cultured for bacteria immediately after collection (0 h) and then stored in a domestic refrigerator from where cultures were repeated at 6-hourly intervals for 24 h. At 0 h, three (3.4%) of the samples were sterile; 56 (64%) grew coagulase negative staphylococci, and one (1.1%) Streptococcus viridans. Thus, 60 (69%) of the samples were either sterile or contained only skin commensals. Twenty-nine (31%) grew potential pathogens--coagulase positive staphylococci in two (2.3%) and mixed growth of staphylococci, coliforms and klebsiella in 25 (28.3%). During the 24 h storage in the refrigerator, bacteria multiplied in 50 and their growth was inhibited in 32 of the samples. But the mean bacterial count at any time during the 24 h was not significantly different from that at the beginning of the storage in the refrigerator. It is proposed that expressed breast milk stored in a domestic refrigerator can be given safely to infants within 24 h of collection if heavy contamination is prevented at the time of collection.

  1. Effect of gamma irradiation on storage time of tomatoes in three different stages of ripending

    International Nuclear Information System (INIS)

    Ozbek, N.; Ozbilgin, S.; Aysan, P.; Celen, H.

    1985-01-01

    Effect of g-irradiation on storage time of tomatoes was studied and tomatoes of Diego variety in three different stages of ripening were used for the experiment. Green-mature tomatoes were treated with 100 and 200 krad, pink (half-mature) tomatoes were treated with 50, 100, 200, 300, 400 and 500 krad doses of gamma rays respectively. After irradiation the tomatoes were stored in a room where the temperature was kept at 22 C with a humidity of 65%. During storage period color changes, softening, spoilage and molding of the fruits were controlled daily, weight loss measurements and all necessary chemical analysis were made periodically. (author)

  2. Defining and measuring the mean residence time of lateral surface transient storage zones in small streams

    Science.gov (United States)

    T.R. Jackson; R. Haggerty; S.V. Apte; A. Coleman; K.J. Drost

    2012-01-01

    Surface transient storage (STS) has functional significance in stream ecosystems because it increases solute interaction with sediments. After volume, mean residence time is the most important metric of STS, but it is unclear how this can be measured accurately or related to other timescales and field-measureable parameters. We studied mean residence time of lateral...

  3. Analysis of dust samples collected from spent nuclear fuel interim storage containers at Hope Creek, Delaware, and Diablo Canyon, California

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Charles R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Enos, David George [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-07-01

    Potentially corrosive environments may form on the surface of spent nuclear fuel dry storage canisters by deliquescence of deposited dusts. To assess this, samples of dust were collected from in-service dry storage canisters at two near-marine sites, the Hope Creek and Diablo Canyon storage installations, and have been characterized with respect to mineralogy, chemistry, and texture. At both sites, terrestrially-derived silicate minerals, including quartz, feldspars, micas, and clays, comprise the largest fraction of the dust. Also significant at both sites were particles of iron and iron-chromium metal and oxides generated by the manufacturing process. Soluble salt phases were minor component of the Hope Creek dusts, and were compositionally similar to inland salt aerosols, rich in calcium, sulfate, and nitrate. At Diablo Canyon, however, sea-salt aerosols, occurring as aggregates of NaCl and Mg-sulfate, were a major component of the dust samples. The seasalt aerosols commonly occurred as hollow spheres, which may have formed by evaporation of suspended aerosol seawater droplets, possibly while rising through the heated annulus between the canister and the overpack. The differences in salt composition and abundance for the two sites are attributed to differences in proximity to the open ocean and wave action. The Diablo Canyon facility is on the shores of the Pacific Ocean, while the Hope Creek facility is on the shores of the Delaware River, several miles from the open ocean.

  4. Comparison of storage stability of odorous VOCs in polyester aluminum and polyvinyl fluoride Tedlar® bags.

    Science.gov (United States)

    Kim, Yong-Hyun; Kim, Ki-Hyun; Jo, Sang-Hee; Jeon, Eui-Chan; Sohn, Jong Ryeul; Parker, David B

    2012-01-27

    Whole air sampling using containers such as flexible bags or rigid canisters is commonly used to collect samples of volatile organic compounds (VOC) in air. The objective of this study was to compare the stability of polyester aluminum (PEA) and polyvinyl fluoride (PVF, brand name Tedlar(®)) bags for gaseous VOC sampling. Eight VOC standards (benzene, toluene, p-xylene, styrene, methyl ethyl ketone, methyl isobutyl ketone, butyl acetate, and isobutyl alcohol) were placed into each bag at storage times of 0, 2, and 3 days prior to analyses by gas chromatography/mass spectrometry (GC/MS). From each bag representing each storage day, samples of 3 different mass loadings were withdrawn and analyzed to derive response factors (RF) of each chemical between the slope of the GC response (y-axis) vs. loaded mass (x-axis). The relative recoveries (RR) of VOC, if derived by dividing RF value of a given storage day by that of 0 day, varied by time, bag type, and VOC type. If the RR values after three days are compared, those of methyl isobutyl ketone were the highest with 96 (PVF) and 99% (PEA); however, the results of isobutyl alcohol were highly contrasting between the two bags with 31 and 94%, respectively. Differences in RR values between the two bag types increased with storage time, such that RR of PEA bags (88±10%) were superior to those of PVF bags (73±22%) after three days, demonstrating that VOC in PEA bags were more stable than in PVF bags. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. The effect of anaerobic digestion and storage on indicator microorganisms in swine and dairy manure.

    Science.gov (United States)

    Costa, Annamaria; Gusmara, Claudia; Gardoni, Davide; Zaninelli, Mauro; Tambone, Fulvia; Sala, Vittorio; Guarino, Marcella

    2017-11-01

    The aim of this experimental study was to evaluate the influence of anaerobic digestion and storage on indicator microorganisms in swine and dairy excreta. Samples were collected every 90 days for 15 months at eight farms, four pig, and four dairy farms, four of them having a biogas plant. Moreover, to evaluate storage effects on samples, 20 l of manure and slurry taken at each farm (digested manure only in farms with a biogas plant) were stored in a controlled climatic chamber at 18 °C, for 6 months. The bacterial load and the chemical-physical characteristics of excreta were evaluated at each sampling time, stored slurry, and manure were sampled and analyzed every 2 months. A high variability of the concentration of bacteria in the different excreta types was observed during the experiment, mainly depending on the type and time of treatment. No sample revealed either the presence of Escherichia coli O157:H7 or of Salmonella, usually linked to the temporary rearing of infected animals in facilities. Anaerobic digestion and storage affected in a significant way the reduction of indicator bacteria like lactobacilli, coliforms, and streptococci. Anaerobic digestion lowered coliforms in pig slurry (- 2.80 log, P manure (- 2.44 log, P < 0.001) and in pig slurry (- 1.43 log, P < 0.05), and lactobacilli in pig slurry (- 3.03 log, P < 0.05). Storage lowered coliforms and the other indicators counts, in particular in fresh wastes, while clostridia did not show a reduction in concentration.

  6. Aggregation and sampling in deterministic chaos: implications for chaos identification in hydrological processes

    Directory of Open Access Journals (Sweden)

    J. D. Salas

    2005-01-01

    Full Text Available A review of the literature reveals conflicting results regarding the existence and inherent nature of chaos in hydrological processes such as precipitation and streamflow, i.e. whether they are low dimensional chaotic or stochastic. This issue is examined further in this paper, particularly the effect that certain types of transformations, such as aggregation and sampling, may have on the identification of the dynamics of the underlying system. First, we investigate the dynamics of daily streamflows for two rivers in Florida, one with strong surface and groundwater storage contributions and the other with a lesser basin storage contribution. Based on estimates of the delay time, the delay time window, and the correlation integral, our results suggest that the river with the stronger basin storage contribution departs significantly from the behavior of a chaotic system, while the departure is less significant for the river with the smaller basin storage contribution. We pose the hypothesis that the chaotic behavior depicted on continuous precipitation fields or small time-step precipitation series becomes less identifiable as the aggregation (or sampling time step increases. Similarly, because streamflows result from a complex transformation of precipitation that involves accumulating and routing excess rainfall throughout the basin and adding surface and groundwater flows, the end result may be that streamflows at the outlet of the basin depart from low dimensional chaotic behavior. We also investigate the effect of aggregation and sampling using series derived from the Lorenz equations and show that, as the aggregation and sampling scales increase, the chaotic behavior deteriorates and eventually ceases to show evidence of low dimensional determinism.

  7. Storage of nuclear wastes

    International Nuclear Information System (INIS)

    Ahlstroem, P.E.

    1988-01-01

    The Swedish system of handling and storage of nuclear wastes is well-developed. Existing plants and systems provide great freedom of action and flexibility regarding future development and decisions of ultimate storage of the spent fuel. The interim storage in CLAB - Central interim storage facility for spent nuclear fuel - could continue without any safety related problems for more than 40 years. In practice the choice of ultimate treatment system is not locked until the encapsulation of the fuel starts. At the same time it is of importance that the generation benefiting by the nuclear power production also be responsible for the development of the ultimate storage system and not unnecessarily postpones important decisions. The ultimate storage system for spent fuel could and should be developed within existing schedule. At the same time is should be worked out to provide coming generations with possibilities to do the type of supervision they like without maintenance and supervision requiring to become a prerequisite for a safe function. (O.S.)

  8. Archival policies and collections database for the Woods Hole Science Center's marine sediment samples

    Science.gov (United States)

    Buczkowski, Brian J.; Kelsey, Sarah A.

    2007-01-01

    The Woods Hole Science Center of the U.S. Geological Survey (USGS) has been an active member of the Woods Hole research community, Woods Hole, Massachusetts, for over 40 years. In that time there have been many projects that involved the collection of sediment samples conducted by USGS scientists and technicians for the research and study of seabed environments and processes. These samples were collected at sea or near shore and then brought back to the Woods Hole Science Center (WHSC) for analysis. While at the center, samples are stored in ambient temperature, refrigerated and freezing conditions ranging from +2º Celsius to -18º Celsius, depending on the best mode of preparation for the study being conducted or the duration of storage planned for the samples. Recently, storage methods and available storage space have become a major concern at the WHSC. The core and sediment archive program described herein has been initiated to set standards for the management, methods, and duration of sample storage. A need has arisen to maintain organizational consistency and define storage protocol. This handbook serves as a reference and guide to all parties interested in using and accessing the WHSC's sample archive and also defines all the steps necessary to construct and maintain an organized collection of geological samples. It answers many questions as to the way in which the archive functions.

  9. Effect of probiotic and storage time of thiamine and riboflavin content in the milk drinks fermented by Lactobacillus casei KNE-1.

    Science.gov (United States)

    Drywień, Małgorzata; Frąckiewicz, Joanna; Górnicka, Magdalena; Gadek, Joanna; Jałosińska, Małgorzata

    2015-01-01

    Fermented milk drinks are unique products due to content of Lactobacillus and Bifidobacterium that are recognized as probiotics. They are a natural component of the colon microbiota as well as commonly used probiotics in functional food. The effects of the storage time and prebiotic type (inuline or oligofructose) were studied in banana-milk drink after fermentation by Lactobacillus casei KNE-1 on the thiamine and riboflavin concentrations. The material for the study was fermented fruit milk drinks: banana-milk prepared in laboratory conditions and fruit milk drinks purchased in a local shop, as a comparative material. The thiamine was determined by thiochrome method and the riboflavin was determined by fluorometric method. The storage time after the end of the fermentation process did not increase the content of thiamine and riboflavin in fermented banana-milk drink more than the output level. The addition of oligofructose significantly affected the synthesis of thiamine by Lactobacillus casei KNE-1 irrespectively of the storage time. The storage time but not the type of prebiotic affected the riboflavin concentration. Taking into account the highest content of both vitamins, the banana-milk drink fermented by Lactobacillus casei KNE-1 should be consumed immediately or 24 days after fermentation. This information could be used by manufacturers for the planning of technological process. The content of thiamine and riboflavin in the fermented milk drinks is the result of the type of prebiotic, the individual bacterial strain properties as well as the storage time. These factors should be investigated to optimize the content of B vitamins in fermented milk drinks in the future.

  10. Improving hydrogen storage in Ni-doped carbon nanospheres

    Energy Technology Data Exchange (ETDEWEB)

    Zubizarreta, L.; Menendez, J.A.; Pis, J.J.; Arenillas, A. [Instituto Nacional del Carbon, CSIC, Apartado 73, 33080 Oviedo (Spain)

    2009-04-15

    The effect of nickel distribution and content in Ni-doped carbon nanospheres on hydrogen storage capacity under conditions of moderate temperature and pressure was studied. It was found that the nickel distribution, obtained by using different doping techniques and conditions, has a noticeable influence on hydrogen storage capacity. The samples with the most homogeneous nickel distribution, obtained by pre-oxidising the carbon nanospheres, displayed the highest storage capacity. In addition, storage capacity is influenced by the amount of nickel. It was found a higher storage capacity in samples containing 5 wt.% of Ni. This is due to the greater interactions between the nickel and the support that produce a higher activation of the solid through a spillover effect. (author)

  11. Investigations of freezing and cold storage for the analysis of peatland dissolved organic carbon (DOC) and absorbance properties.

    Science.gov (United States)

    Peacock, Mike; Freeman, Chris; Gauci, Vincent; Lebron, Inma; Evans, Chris D

    2015-07-01

    Although measured rates of biological degradation of DOC are typically low under dark conditions, it is assumed that water samples must be analysed soon after collection to provide an accurate measure of DOC concentration and UV-visible absorbance. To examine the impact of storage on DOC quality and quantity, we took water samples from an ombrotrophic peatland, and stored them in the dark at 4 °C for 138-1082 days. A median of 29% of DOC was lost during storage, but losses of absorbance at 254 nm were less. DOC loss followed a first-order exponential decay function, and was dependent on storage time. DOC half-life was calculated as 1253 days. Specific absorbance at 254 nm suggested that samples containing more aromatic DOC were more resistant to degradation, although time functioned as the primary control. Samples from two fens showed that loss of absorbance was greater at 400 nm rather than 254 nm, after 192 days storage, suggesting that non-aromatic DOC is preferentially degraded. These results suggest that samples can be stored for several months before losses of DOC become detectable, and that it is possible to back-calculate initial DOC concentrations in long-term stored samples based on known decay rates. Freeze/thaw experiments using samples from a range of peatlands suggested that DOC concentration was mostly unaffected by the process, but DOC increased 37% in one sample. Freezing had unpredictable and sometimes strong effects on absorbance, SUVA and E ratios, therefore freezing is not recommended as a method of preservation for these analyses.

  12. Identification of continuous-time systems from samples of input ...

    Indian Academy of Sciences (India)

    Abstract. This paper presents an introductory survey of the methods that have been developed for identification of continuous-time systems from samples of input±output data. The two basic approaches may be described as (i) the indirect method, where first a discrete-time model is estimated from the sampled data and then ...

  13. Effects of low-level gamma irradiation on the characteristics of fermented pork sausage during storage

    International Nuclear Information System (INIS)

    Kim, I.S.; Jo, C.; Lee, K.H.; Lee, E.J.; Ahn, D.U.; Kang, S.N.

    2012-01-01

    The effect of gamma irradiation (0.5, 1, 2, and 4 kGy) on the quality of vacuum-packaged dry fermented sausages during refrigerated storage was evaluated. At Day 0 of irradiation, the pH, redness (CIE a ⁎ ), yellowness (CIE b ⁎ ), 2-thiobarbituric acid-reactive substances (TBARS) and volatile basic nitrogen (VBN) values of samples irradiated at 2 and 4 kGy were higher (p ⁎ values (lightness) were lower than those of the non-irradiated control (p ⁎ , CIE a ⁎ and CIE b ⁎ -value of samples were not significantly influenced by irradiation. The CIE a ⁎ , and CIE b ⁎ -values of samples irradiated at 2 and 4 kGy decreased with the increase of storage time. The VBN, TBARS, and CIE L ⁎ -values of samples irradiated at 4 kGy were not changed significantly during refrigerated storage for 90 days (p>0.05). The total plate counts (TPC) and lactic acid bacteria (LAB) in the samples irradiated at 4 kGy were significantly lower (p<0.01) than those with lower irradiation doses. At the end of storage, the TPC, coliform, and LAB in the samples were not increased after irradiation at 1, 0.5 and 1 kGy, respectively. TPC and LAB were not detected in samples irradiated at 4 kGy at Day 90. In addition, no coliform bacteria were found in samples irradiated at 1 kGy during refrigerated storage. Sensory evaluation indicated that the rancid flavor of samples irradiated at 4 kGy was significantly higher, but aroma and taste scores were lower than those of the control at Day 3 of storage. Irradiation of dry fermented sausages at 2 kGy was the best conditions to prolong the shelf-life and decrease the rancid flavor without significant quality deterioration. - Highlights: ► Effect of gamma irradiation on the quality of vacuum-packaged dry fermented sausages during refrigerated storage was evaluated. ► At Day 90, the TPC, coliform, and LAB in the dry fermented sausages were not increased after irradiation at 2, 0.5 and 4 kGy, respectively. ► TPC and LAB were not detected in

  14. Hydrogen storage properties for Mg–Zn–Y quasicrystal and ternary alloys

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Xuanli, E-mail: Xuanli.Luo@nottingham.ac.uk; Grant, David M., E-mail: David.Grant@nottingham.ac.uk; Walker, Gavin S., E-mail: Gavin.Walker@nottingham.ac.uk

    2015-10-05

    Highlights: • Quasicrystal (QC) and H-phase alloys were detected in the Zn–Mg–Y samples. • Hydrogen storage properties of Zn–Mg–Y samples were investigated. • Zn{sub 50}Mg{sub 42}Y{sub 8} showed a capacity of 0.9 wt.% and decomposition temperature of 445 °C. - Abstract: Three Zn–Mg–Y alloys with nominal compositions of Zn{sub 50}Mg{sub 42}Y{sub 8} and Zn{sub 60}Mg{sub 30}Y{sub 10} were prepared by induction melting or gas atomisation. XRD and SEM analysis shows samples ZMY-1 and ZMY-2 consisted of multiple phases including icosahedral quasicrystal (QC) i-phase, hexagonal H-phase and Mg{sub 7}Zn{sub 3}, whilst ZMY-3 contained QC only. The hydrogen storage properties of the Zn–Mg–Y quasicrystal and ternary alloys were investigated for the first time. The quasicrystal sample ZMY-3 hydrogenated at 300 °C had 0.3 wt.% capacity and the DSC decomposition peak temperature was 503 °C. Amongst the three samples, the highest hydrogen storage capacity (0.9 wt.%) and the lowest decomposition peak temperature (445 °C) was achieved by sample ZMY-1. The pressure–composition–isotherm (PCI) curve of ZMY-1 sample showed a flat plateau gave a plateau pressure of 3.5 bar at 300 °C, which indicates a lower dehydrogenation enthalpy than MgH{sub 2}.

  15. Keeping quality of raisins as affected by irradiation, storage environments and combination treatments

    International Nuclear Information System (INIS)

    Hussain, B.; Afridi, S.; Durrani, M.J.

    1989-01-01

    Influence of irradiation and storage environments on the quality of raisins was investigated during storage at room temperature for six months. Storage environment included: packaging in clear polyethylene bags in the presence of normal air, nitrogen and vacuum. Insect infestation appeared after two months storage and reached to 5.8, 8.6, 11.7 and 25.8% in the control samples stored in normal air for 3, 4, 5 and 6 months storage, respectively. No infestation was observed in vacuum nitrogen and packed samples. In irradiated samples no infestation was observed during storage in normal air and also vacuum and nitrogen packed samples. Raisin samples packed under vacuum were better in quality than other treatments. (author)

  16. STORAGE STABILITY OF PESTICIDES IN EXTRACT SOLVENTS AND SAMPLING MEDIA

    Science.gov (United States)

    Demonstrating that pesticides are stable in field media and their extracts over extended storage periods allows operational flexibility and cost efficiency. Stability of the 31 neutral pesticides and 2 acid herbicides of the Agricultural Health Study exposure pilot was evaluate...

  17. Germination and storage of caranda seeds (Copernicia alba

    Directory of Open Access Journals (Sweden)

    Tathiana Elisa Masetto

    2012-12-01

    Full Text Available Caranda is a Brazilian native palm tree, belonging to Arecaceae family and occurring, predominan,t in the Brazilian Swampland. This work studied the germination and the caranda seeds storage behavior. The germination study was carried out in the temperatures of 25ºC and 30ºC in constant white light and the alternate temperature of 20/30ºC with 10 hours of darkness for the lowest temperature and 14 hours of light for the highest temperature, using paper and paper roll as substratum. At the end of test, the germination percentage, germination speed index, germination medium time and the primary root length were evaluated. After the seeds improvement, it was obtained two sub-samples destined for 30 days storage in two invironments: cold and dry chamber (16ºC/55% UR and freezer (-18ºC. The following tests, water content, germination, germination medium time and primary root length were evaluated. The caranda seeds germination in paper roll and on paper is favored by the temperature of 20/30ºC in paper roll and on paper and paper roll on 30ºC. The freezing and cold camera storage during 30 days are efficient to reduce the germination medium time of caranda seeds and to keep the germination percentage.

  18. Variation of nephrotoxicity biomarkers by urinary storage condition in rats.

    Science.gov (United States)

    Le, Jung-Min; Han, Young-Hwan; Choi, Su-Jeong; Park, Ju-Seong; Jang, Jeong-Jun; Bae, Re-Ji-Na; Lee, Mi Ju; Kim, Myoung Jun; Lee, Yong-Hoon; Kim, Duyeol; Lee, Hye-Young; Park, Sun-Hee; Park, Cheol-Beom; Kang, Jin Seok; Kang, Jong-Koo

    2014-12-01

    Recently, there has been an increase in the use of several nephrotoxicity biomarkers in preclinical experiments. In addition, it has been indicated that the result may have been influenced by secondary factors, such as sample storage condition or storage period. In this study, we have assessed the variation in urinary nephrotoxicity biomarkers as a result of urine storage conditions and storage period of the urine. Urine was sampled from specific pathogen-free Sprague-Dawley rats (19 weeks old), which were housed individually in hanged stainless steel wire mesh cages. Urine was stored at 20℃, at 4℃, or at -70℃ after sampling. The levels of the biomarkers such as beta-2 microglobulin (B2M), cystatin-C (Cys-C), N-acetyl-β- D-glucosaminidase (NAG), micro albumin (MA), micro protein (MP) were measured at 6, 24, 48 and 144 hr after sampling. The B2M level was significantly decreased at 6, 24, 48, and 144 hr compared to 0 hr at -70℃ (p storage conditions. Taken together, B2M and Cys-C levels were modulated by storage temperature and period. For the enhancement of test accuracy, it is suggested that strict protocols be established for samples to minimize the effects of the storage conditions on the detected levels of biomarkers.

  19. Effects of sterilization, packaging, and storage on vitamin C degradation, protein denaturation, and glycation in fortified milks.

    Science.gov (United States)

    Gliguem, H; Birlouez-Aragon, I

    2005-03-01

    Monitoring the nutritional quality of dietetic milk throughout its shelf life is particularly important due to the high susceptibility of some vitamins to oxidation, and the continuous development of the Maillard reaction during storage. The objective of this paper was to evaluate the vitamin C content and protein modification by denaturation and glycation on fortified milk samples (growth milks) destined for 1- to 3-yr-old children. The influences of the sterilization process, formulation, packaging, and storage duration at ambient temperature in the dark were studied. Vitamin C degradation was particularly influenced by type of packaging. The use of a 3-layered opaque bottle was associated with complete oxidation of vitamin C after 1 mo of storage, whereas in the 6-layered opaque bottle, which has an oxygen barrier, the vitamin C content slowly decreased to reach 25% of the initial concentration after 4 mo of storage. However, no significant effect of vitamin C degradation during storage could be observed in terms of Maillard reaction, despite the fact that a probable impact occurred during sterilization. Furosine content and the FAST (fluorescence of advanced Maillard products and soluble tryptophan) index-indicators of the early and advanced Maillard reaction, respectively-were significantly higher in the in-bottle sterilized milk samples compared with UHT samples, and in fortified milk samples compared with cow milk. However, after 1 mo, the impact of storage was predominant, increasing the furosine level and the FAST index at similar levels for the differently processed samples. The early Maillard reaction developed continuously throughout the storage period.In conclusion, only packaging comprising an oxygen and light barrier is compatible with vitamin C fortification of milk. Furthermore, short storage time or low storage temperature is needed to retard vitamin C degradation, protein denaturation, and development of the Maillard reaction.

  20. Effects of storage and processing on residue levels of chlorpyrifos in soybeans.

    Science.gov (United States)

    Zhao, Liuwei; Ge, Jing; Liu, Fengmao; Jiang, Naiwen

    2014-05-01

    The residue levels of chlorpyrifos in soybeans during storage and processing were investigated. Soybeans were treated with chlorpyrifos aqueous solution and placed in a sealed plastic container. The residue of chlorpyrifos was determined in soybeans at six time points within 0 and 112days during storage and oil processing of the soybeans was conducted. The analysis of the residues of chlorpyrifos was carried out by gas chromatography-mass spectrometry (GC-MS). Results show that the dissipation of chlorpyrifos in soybeans is about 62% during the storage period. Moreover, the carryover of the residues from soybeans into oil is found to be related to the processing methods. Processing factor, which is defined as the ratio of chlorpyrifos residue concentration in oil sample to that in the soybean samples, was 11 and 0.25 after cold and hot pressing, respectively. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. A muon storage ring for neutrino beams

    International Nuclear Information System (INIS)

    Lee, W.; Neuffer, D.

    1988-01-01

    A muon storage ring can provide electron and muon neutrino beams of precisely knowable flux. Constraints on muon collection and storage-ring design are discussed. Sample muon storage rings are presented and muon and neutrino intensities are estimated. Experimental use of the ν-beams, detector properties, and possible variations are described. Future directions for conceptual designs are outlined. 11 refs., 4 figs., 3 tabs

  2. Influence of Storage on Briquettes Mechanical Properties

    Directory of Open Access Journals (Sweden)

    Brožek M.

    2014-09-01

    Full Text Available The effects of the storage place, placing manner, and storage time on mechanical properties of briquettes made from birch chips were laboratorily tested. A unique methodology developed by the present author enabling a relatively easy assessment of mechanical properties of the briquettes is described. The briquettes properties were evaluated by their density and rupture force determination. From the test results it follows that if the briquettes are stored in a well closed plastic bag, neither the place nor the storage time influence significantly their life time. When stored in a net plastic bag, the briquettes get seriously damaged, namely depending on their storage place and storage time.

  3. High Density Digital Data Storage System

    Science.gov (United States)

    Wright, Kenneth D., II; Gray, David L.; Rowland, Wayne D.

    1991-01-01

    The High Density Digital Data Storage System was designed to provide a cost effective means for storing real-time data from the field-deployable digital acoustic measurement system. However, the high density data storage system is a standalone system that could provide a storage solution for many other real time data acquisition applications. The storage system has inputs for up to 20 channels of 16-bit digital data. The high density tape recorders presently being used in the storage system are capable of storing over 5 gigabytes of data at overall transfer rates of 500 kilobytes per second. However, through the use of data compression techniques the system storage capacity and transfer rate can be doubled. Two tape recorders have been incorporated into the storage system to produce a backup tape of data in real-time. An analog output is provided for each data channel as a means of monitoring the data as it is being recorded.

  4. Low-sampling-rate ultra-wideband channel estimation using equivalent-time sampling

    KAUST Repository

    Ballal, Tarig

    2014-09-01

    In this paper, a low-sampling-rate scheme for ultra-wideband channel estimation is proposed. The scheme exploits multiple observations generated by transmitting multiple pulses. In the proposed scheme, P pulses are transmitted to produce channel impulse response estimates at a desired sampling rate, while the ADC samples at a rate that is P times slower. To avoid loss of fidelity, the number of sampling periods (based on the desired rate) in the inter-pulse interval is restricted to be co-prime with P. This condition is affected when clock drift is present and the transmitted pulse locations change. To handle this case, and to achieve an overall good channel estimation performance, without using prior information, we derive an improved estimator based on the bounded data uncertainty (BDU) model. It is shown that this estimator is related to the Bayesian linear minimum mean squared error (LMMSE) estimator. Channel estimation performance of the proposed sub-sampling scheme combined with the new estimator is assessed in simulation. The results show that high reduction in sampling rate can be achieved. The proposed estimator outperforms the least squares estimator in almost all cases, while in the high SNR regime it also outperforms the LMMSE estimator. In addition to channel estimation, a synchronization method is also proposed that utilizes the same pulse sequence used for channel estimation. © 2014 IEEE.

  5. Pseudo-single-bunch mode for a 100 MHz storage ring serving soft X-ray timing experiments

    Science.gov (United States)

    Olsson, T.; Leemann, S. C.; Georgiev, G.; Paraskaki, G.

    2018-06-01

    At many storage rings for synchrotron light production there is demand for serving both high-flux and timing users simultaneously. Today this is most commonly achieved by operating inhomogeneous fill patterns, but this is not preferable for rings that employ passive harmonic cavities to damp instabilities and increase Touschek lifetime. For these rings, inhomogeneous fill patterns could severely reduce the effect of the harmonic cavities. It is therefore of interest to develop methods to serve high-flux and timing users simultaneously without requiring gaps in the fill pattern. One such method is pseudo-single-bunch (PSB), where one bunch in the bunch train is kicked onto another orbit by a fast stripline kicker. The light emitted from the kicked bunch can then be separated by an aperture in the beamline. Due to recent developments in fast kicker design, PSB operation in multibunch mode is within reach for rings that operate with a 100 MHz RF system, such as the MAX IV and Solaris storage rings. This paper describes machine requirements and resulting performance for such a mode at the MAX IV 1.5 GeV storage ring. A solution for serving all beamlines is discussed as well as the consequences of beamline design and operation in the soft X-ray energy range.

  6. 303-K Storage Facility: Report on FY98 closure activities

    International Nuclear Information System (INIS)

    Adler, J.G.

    1998-01-01

    This report summarizes and evaluates the decontamination activities, sampling activities, and sample analysis performed in support of the closure of the 303-K Storage Facility. The evaluation is based on the validated data included in the data validation package (98-EAP-346) for the 303-K Storage Facility. The results of this evaluation will be used for assessing contamination for the purpose of closing the 303-K Storage Facility as described in the 303-K Storage Facility Closure Plan, DOE/RL-90-04. The closure strategy for the 303-K Storage Facility is to decontaminate the interior of the north half of the 303-K Building to remove known or suspected dangerous waste contamination, to sample the interior concrete and exterior soils for the constituents of concern, and then to perform data analysis, with an evaluation to determine if the closure activities and data meet the closure criteria. The closure criteria for the 303-K Storage Facility is that the concentrations of constituents of concern are not present above the cleanup levels. Based on the evaluation of the decontamination activities, sampling activities, and sample data, determination has been made that the soils at the 303-K Storage Facility meet the cleanup performance standards (WMH 1997) and can be clean closed. The evaluation determined that the 303-K Building cannot be clean closed without additional closure activities. An additional evaluation will be needed to determine the specific activities required to clean close the 303-K Storage Facility. The radiological contamination at the 303-K Storage Facility is not addressed by the closure strategy

  7. On the sample transport time of a pneumatic transfer system

    International Nuclear Information System (INIS)

    Kondo, Yoshihide

    1983-01-01

    The counts accumulated in measuring system are affected by the variations in transport time of the sample on cyclic activation experiments with a mechanical sample transfer system. In use of the pneumatic transfer system, which has been set up, the transport time is variable according to the differences as follows: The form, size and weight of samples, the pneumatic pressure and so on. Comprehending the relationships between the transpot time and these variable factors is essentially important to make experiments with this transfer system. (author)

  8. Effects of retail style or food service style packaging type and storage time on sensory characteristics of bacon manufactured from commercially sourced pork bellies.

    Science.gov (United States)

    Lowe, B K; Bohrer, B M; Holmer, S F; Boler, D D; Dilger, A C

    2014-06-01

    Objectives were to characterize differences in pork bellies that were stored frozen for different durations prior to processing and characterize sensory properties of the bacon derived from those bellies when stored in either retail or food service style packaging. Bellies (n = 102) were collected from 4 different time periods, fresh bellies (never frozen) and bellies frozen for 2, 5, or 7 mo, and manufactured into bacon under commercial conditions. Food service bacon was packaged in oxygen-permeable polyvinyl lined boxes layered on wax-covered lined paper and blast frozen (-33 °C) for 45 or 90 d after slicing. Retail bacon was vacuum-packaged in retail packages and refrigerated (2 °C) in the dark for 60 or 120 d after slicing. At the end of respective storage times after slicing, bacon was analyzed for sensory attributes and lipid oxidation. Off-flavor and oxidized odor of bacon increased (P food service packaged bacon from frozen bellies, but was unchanged (P ≥ 0.07) with time in food service packaged bacon from fresh bellies. Lipid oxidation was also unchanged (P ≥ 0.21) over time in retail packaged bacon, with the exception of bellies frozen for 5 mo, which was increased from day 0 to day 90. Overall, off-flavor, oxidized odor, and lipid oxidation increased as storage time after processing increased. Freezing bellies before processing may exacerbate lipid oxidation as storage time after processing was extended. Bacon can be packaged and managed several different ways before it reaches the consumer. This research simulated food service (frozen) and retail packaged (refrigerated) bacon over a range of storage times after slicing. Off-flavor and oxidized odor increased as storage time after processing increased in both packaging types. Lipid oxidation increased as storage time after slicing increased to a greater extent in food service packaging. © 2014 Institute of Food Technologists®

  9. Time dependence of the pH of rain

    Science.gov (United States)

    John A. Kadlecek; Volkar A. Mohnen

    1976-01-01

    Standard procedures for determining the pH of rain samples usually involve substantial delays from the time of rainfall to the time of analysis. This assumes that no change in pH occurs during the storage period. We have found that this is not always true. We have determined that individual rain water samples possess a time dependent pH which can be correlated with the...

  10. Flow and Residence Times of Dynamic River Bank Storage and Sinuosity-Driven Hyporheic Exchange

    Science.gov (United States)

    Gomez-Velez, J. D.; Wilson, J. L.; Cardenas, M. B.; Harvey, J. W.

    2017-10-01

    Hydrologic exchange fluxes (HEFs) vary significantly along river corridors due to spatiotemporal changes in discharge and geomorphology. This variability results in the emergence of biogeochemical hot-spots and hot-moments that ultimately control solute and energy transport and ecosystem services from the local to the watershed scales. In this work, we use a reduced-order model to gain mechanistic understanding of river bank storage and sinuosity-driven hyporheic exchange induced by transient river discharge. This is the first time that a systematic analysis of both processes is presented and serves as an initial step to propose parsimonious, physics-based models for better predictions of water quality at the large watershed scale. The effects of channel sinuosity, alluvial valley slope, hydraulic conductivity, and river stage forcing intensity and duration are encapsulated in dimensionless variables that can be easily estimated or constrained. We find that the importance of perturbations in the hyporheic zone's flux, residence times, and geometry is mainly explained by two-dimensionless variables representing the ratio of the hydraulic time constant of the aquifer and the duration of the event (Γd) and the importance of the ambient groundwater flow (Δh∗). Our model additionally shows that even systems with small sensitivity, resulting in small changes in the hyporheic zone extent, are characterized by highly variable exchange fluxes and residence times. These findings highlight the importance of including dynamic changes in hyporheic zones for typical HEF models such as the transient storage model.

  11. Evaluation of Glucose-6-Phosphate Dehydrogenase stability in stored blood samples.

    Science.gov (United States)

    Jalil, Norunaluwar; Azma, Raja Zahratul; Mohamed, Emida; Ithnin, Azlin; Alauddin, Hafiza; Baya, Siti Noor; Othman, Ainoon

    2016-01-01

    Glucose-6-Phosphate Dehydrogenase (G6PD) deficiency is the commonest cause of neonatal jaundice in Malaysia. Recently, OSMMR2000-D G6PD Assay Kit has been introduced to quantitate the level of G6PD activity in newborns delivered in Universiti Kebangsaan Malaysia Medical Centre (UKMMC). As duration of sample storage prior to analysis is one of the matters of concern, this study was conducted to identify the stability of G6PD enzyme during storage. A total of 188 cord blood samples from normal term newborns delivered at UKMMC were selected for this study. The cord bloods samples were collected in ethylene-diamine-tetra-acetic acid (EDTA) tubes and refrigerated at 2-8 °C. In addition, 32 out of 188 cord blood samples were spotted on chromatography paper, air-dried and stored at room temperature. G6PD enzyme activities were measured daily for 7 days using the OSMMR2000-D G6PD Assay Kit on both the EDTA blood and dried blood samples. The mean value for G6PD activity was compared between days of analysis using Student Paired T-Test. In this study, 172 out of 188 cord blood samples showed normal enzyme levels while 16 had levels corresponding to severe enzyme deficiency. The daily mean G6PD activity for EDTA blood samples of newborns with normal G6PD activity showed a significant drop on the fourth day of storage (p samples with severely deficient G6PD activity, significant drop was seen on third day of storage (p = 0.002). Analysis of dried cord blood showed a significant reduction in enzyme activity as early as the second day of storage (p = 0.001). It was also noted that mean G6PD activity for spotted blood samples were lower compared to those in EDTA tubes for all days (p = 0.001). Thus, EDTA blood samples stored at 2-8 °C appeared to have better stability in terms of their G6PD enzyme level as compared to dried blood samples on filter paper, giving a storage time of up to 3 days.

  12. Sensory Quality of Standard and Light Mayonnaise during Storage

    Directory of Open Access Journals (Sweden)

    Romana Karas

    2002-01-01

    Full Text Available The effects of ingredients on the quality and stability of two kinds of mayonnaise after it has been stored in a refrigerator (t = 5–8 °C and at room temperature (t = 20–25 °C were examined in this research. Fresh mayonnaise samples were examined by sensory analysis (analytical descriptive test and physico-chemical analyses (pH, acid and peroxide values first after being stored for one month and then after two months. The effects of individual factors were examined and the results were statistically valued. The results show that fresh standard mayonnaise containing 75 % of oil as opposed to low-fat mayonnaise (light mayonnaise containing 49 % of oil gained higher grades for most sensory attributes. Storage temperature, storage time and type of mayonnaise influence significantly (P≤0.001 the stability, homogeneity, mouth feeling, acid odour and flavour, rancidity, pH, acid and peroxide values. At any point of storage and under both temperature regimes, the samples of light mayonnaise had lower pH value and higher acid value in comparison with standard mayonnaise. Regardless of storage conditions irrespective of the recipe for their preparation, pH value was declining, whereas acid and peroxide values increased in all types of mayonnaise. Some meaningful statistically significant correlations (r > 0.70 exist between sensory and physico-chemical parametres of mayonnaise.

  13. Effect of gamma-irradiation and extended storage on chemical quality in onion (Allium cepa L.)

    International Nuclear Information System (INIS)

    Croci, C.A.; Banek, S.A.; Curzio, O.A.

    1995-01-01

    The effects of gamma-irradiation and long-term storage on the chemical quality of the Valenciana sintética 14 onion variety were determined under warehouse conditions in two sets of bulbs grown consecutively in 1988 and 1989. In both years irradiated and non-irradiated bulbs showed similar behaviour in terms of carbohydrate and ascorbic acid contents throughout the 300 days of storage. It was found that the carbohydrate content significantly decreased in irradiated and non-irradiated samples up to 180 days of storage. The storage time was found not to have a significant effect on the ascorbic acid content of bulbs. The carbohydrate and ascorbic acid contents were found to be higher in the irradiated and non-irradiated bulbs grown in 1988. Neither storage time nor gamma-irradiation nor the specific year significantly affected dry matter or acidity. Gamma-irradiation did not significantly affect flavour strength in terms of total pyruvate content

  14. Cold storage as a method for the long-term preservation of tropical dissolved organic carbon (DOC

    Directory of Open Access Journals (Sweden)

    S. Cook

    2016-11-01

    Full Text Available Fluvial fluxes of dissolved organic carbon (DOC may represent an important loss for terrestrial carbon stores in the tropics. However, there is currently limited guidance on the preservation of tropical water samples for DOC analysis. Commonly employed preservation techniques such as freezing or acidification can limit degradation but may also alter sample properties, complicating DOC analysis. We examined the effects of cold storage at 4 °C on DOC concentration and quality in water samples collected from a tropical peat catchment. Samples were stored in the dark at 4 °C for periods of 6–12 weeks. Freeze/thaw experiments were also made. Mean DOC concentrations in samples stored for six weeks at 4 °C were 6.1 % greater than in samples stored at ambient room temperature (33 °C over the same period. Changes in DOC concentrations, in two sample sets, during cold storage were 2.25 ± 2.9 mg L-1 (8 % to 2.69 ± 1.4 mg L-1 (11 % over a 12-week period. Freeze/thaw resulted in alterations in the optical properties of samples, and this in turn altered the calculated DOC concentrations by an average of 10.9 %. We conclude that cold storage at 4 °C is an acceptable preservation method for tropical DOC water samples, for moderate time periods, and is preferable to freezing or storage at ambient temperatures.

  15. NV Energy Electricity Storage Valuation

    Energy Technology Data Exchange (ETDEWEB)

    Ellison, James F.; Bhatnagar, Dhruv; Samaan, Nader A.; Jin, Chunlian

    2013-06-30

    This study examines how grid-level electricity storage may benet the operations of NV Energy in 2020, and assesses whether those benets justify the cost of the storage system. In order to determine how grid-level storage might impact NV Energy, an hourly production cost model of the Nevada Balancing Authority (\\BA") as projected for 2020 was built and used for the study. Storage facilities were found to add value primarily by providing reserve. Value provided by the provision of time-of-day shifting was found to be limited. If regulating reserve from storage is valued the same as that from slower ramp rate resources, then it appears that a reciprocating engine generator could provide additional capacity at a lower cost than a pumped storage hydro plant or large storage capacity battery system. In addition, a 25-MW battery storage facility would need to cost $650/kW or less in order to produce a positive Net Present Value (NPV). However, if regulating reserve provided by storage is considered to be more useful to the grid than that from slower ramp rate resources, then a grid-level storage facility may have a positive NPV even at today's storage system capital costs. The value of having storage provide services beyond reserve and time-of-day shifting was not assessed in this study, and was therefore not included in storage cost-benefit calculations.

  16. Duddingtonia flagrans chlamydospores in nutritional pellets: effect of storage time and conditions on the trapping ability against Haemonchus contortus larvae.

    Science.gov (United States)

    Fitz-Aranda, J A; Mendoza-de-Gives, P; Torres-Acosta, J F J; Liébano-Hernández, E; López-Arellano, M E; Sandoval-Castro, C A; Quiroz-Romero, H

    2015-01-01

    The study evaluated the effect of storage time and conditions of nutritional pellets (NP) containing Duddingtonia flagrans chlamydospores on its in vitro trapping ability against Haemonchus contortus L3 larvae. The treated batch (200 NP) contained 4 × 106 chlamydospores of the FTH0-8 strain, whereas the control batch (200 NP) was produced without spores. Both NP batches were exposed to four experimental storage conditions: (T1) shelves (indoors); (T2) refrigeration (4°C); (T3) outdoors under a roof; and (T4) 100% outdoors. Each group comprised 48 NP with spores and 48 NP without spores (control). The ability of D. flagrans spores to trap H. contortus L3 larvae was evaluated for 8 weeks for each storage condition. For that purpose, six randomly selected NP with spores were compared to their respective control NP. Each NP was individually crushed. The crushed material (1 g) was placed on the surface of a 2% water agar plate with 200 H. contortus L3 larvae. Plates were sealed and were incubated at room temperature for 8 days. The whole content of every plate was transferred to a Baermann apparatus to recover the remaining larvae. There was a clear larval reduction in the NP with spores, compared to the respective control NP in the four storage conditions (PT2), 77 ± 6.1 (T1), 81.5 ± 3.8 (T4) and 82.1 ± 2.5 (T3). Larval reductions were similar at all times and were not affected by storage conditions or storage time (R 20.05). The long-term shelf-life of the chlamydospores in the NP suggests that this spore dosage technology is a viable option.

  17. Adaptive control of theophylline therapy: importance of blood sampling times.

    Science.gov (United States)

    D'Argenio, D Z; Khakmahd, K

    1983-10-01

    A two-observation protocol for estimating theophylline clearance during a constant-rate intravenous infusion is used to examine the importance of blood sampling schedules with regard to the information content of resulting concentration data. Guided by a theory for calculating maximally informative sample times, population simulations are used to assess the effect of specific sampling times on the precision of resulting clearance estimates and subsequent predictions of theophylline plasma concentrations. The simulations incorporated noise terms for intersubject variability, dosing errors, sample collection errors, and assay error. Clearance was estimated using Chiou's method, least squares, and a Bayesian estimation procedure. The results of these simulations suggest that clinically significant estimation and prediction errors may result when using the above two-point protocol for estimating theophylline clearance if the time separating the two blood samples is less than one population mean elimination half-life.

  18. Time and dose assessment of barge shipment and at-reactor handling of a CASTOR V/21 spent fuel storage cask

    Energy Technology Data Exchange (ETDEWEB)

    Hostick, C.J. (Pacific Northwest Lab., Richland, WA (United States)); Lavender, J.C. (Westinghouse Hanford Co., Richland, WA (United States)); Wakeman, B.H. (Virginia Electric and Power Co., Richmond, VA (United States))

    1992-04-01

    This report contains the results of a time/motion analysis and a radiation dose assessment made during the receipt from barge transport and the loading of CAst iron cask for Storage and Transport Of Radioactive material (CASTOR) V/21 storage casks with spent nuclear fuel at the Surry Power Station in Virginia during 1987. The study was a cooperative effort between Pacific Northwest Laboratory (PNL) and Virginia Electric and Power Company (Virginia Power), and was funded by the US Department of Energy (DOE) Transportation Program Office. In this study, cask handling activities were tracked at the Surry Power Station, tracing the transfer of the empty spent fuel storage cask from an ocean-going vessel to a barge for river transport through the activities required to place the loaded storage cask at an at-reactor storage location.

  19. SECON - A tool for estimation of storage costs and storage project revenue

    International Nuclear Information System (INIS)

    Hall, O.

    1997-01-01

    The SECON model Storage ECONomics is useful for gas suppliers, storage operators, gas distributors and consumers when investigating new storage possibilities. SECON has been used within the Sydkraft group to compare cost for different types of storage and to identify the market niche for lined rock cavern (LRC) storage. In the model cost for the different storage types, salt caverns, LNG, and LRC can be compared. By using input according to market needs each storage type can be validated for a specific service e.g. peak shaving, seasonal storage or balancing. The project revenue can also be calculated. SECON includes three models for income calculation; US storage service, Trading and Avoided Supply Contract Costs. The income models calculates annual turnover, pay of time, net present value, internal rate of return and max. liquidity shortfall for the project. The SECON will facilitate sensitivity analysis both regarding cost for different services and different storage types and on the income side by using different scenarios. At the poster session SECON will be presented live and the delegates will have the opportunity to test the model. (au)

  20. Evaluation of FTA cards as a laboratory and field sampling device for the detection of foot-and-mouth disease virus and serotyping by RT-PCR and real-time RT-PCR.

    Science.gov (United States)

    Muthukrishnan, Madhanmohan; Singanallur, Nagendrakumar B; Ralla, Kumar; Villuppanoor, Srinivasan A

    2008-08-01

    Foot-and-mouth disease virus (FMDV) samples transported to the laboratory from far and inaccessible areas for serodiagnosis pose a major problem in a tropical country like India, where there is maximum temperature fluctuation. Inadequate storage methods lead to spoilage of FMDV samples collected from clinically positive animals in the field. Such samples are declared as non-typeable by the typing laboratories with the consequent loss of valuable epidemiological data. The present study evaluated the usefulness of FTA Classic Cards for the collection, shipment, storage and identification of the FMDV genome by RT-PCR and real-time RT-PCR. The stability of the viral RNA, the absence of infectivity and ease of processing the sample for molecular methods make the FTA cards a useful option for transport of FMDV genome for identification and serotyping. The method can be used routinely for FMDV research as it is economical and the cards can be transported easily in envelopes by regular document transport methods. Live virus cannot be isolated from samples collected in FTA cards, which is a limitation. This property can be viewed as an advantage as it limits the risk of transmission of live virus.

  1. Membrane biofouling characterization: effects of sample preparation procedures on biofilm structure and the microbial community

    KAUST Repository

    Xue, Zheng

    2014-07-15

    Ensuring the quality and reproducibility of results from biofilm structure and microbial community analysis is essential to membrane biofouling studies. This study evaluated the impacts of three sample preparation factors (ie number of buffer rinses, storage time at 4°C, and DNA extraction method) on the downstream analysis of nitrifying biofilms grown on ultrafiltration membranes. Both rinse and storage affected biofilm structure, as suggested by their strong correlation with total biovolume, biofilm thickness, roughness and the spatial distribution of EPS. Significant variations in DNA yields and microbial community diversity were also observed among samples treated by different rinses, storage and DNA extraction methods. For the tested biofilms, two rinses, no storage and DNA extraction with both mechanical and chemical cell lysis from attached biofilm were the optimal sample preparation procedures for obtaining accurate information about biofilm structure, EPS distribution and the microbial community. © 2014 © 2014 Taylor & Francis.

  2. Quantification of Campylobacter spp. in chicken rinse samples by using flotation prior to real-time PCR.

    Science.gov (United States)

    Wolffs, Petra; Norling, Börje; Hoorfar, Jeffrey; Griffiths, Mansel; Rådström, Peter

    2005-10-01

    Real-time PCR is fast, sensitive, specific, and can deliver quantitative data; however, two disadvantages are that this technology is sensitive to inhibition by food and that it does not distinguish between DNA originating from viable, viable nonculturable (VNC), and dead cells. For this reason, real-time PCR has been combined with a novel discontinuous buoyant density gradient method, called flotation, in order to allow detection of only viable and VNC cells of thermotolerant campylobacters in chicken rinse samples. Studying the buoyant densities of different Campylobacter spp. showed that densities changed at different time points during growth; however, all varied between 1.065 and 1.109 g/ml. These data were then used to develop a flotation assay. Results showed that after flotation and real-time PCR, cell concentrations as low as 8.6 x 10(2) CFU/ml could be detected without culture enrichment and amounts as low as 2.6 x 10(3) CFU/ml could be quantified. Furthermore, subjecting viable cells and dead cells to flotation showed that viable cells were recovered after flotation treatment but that dead cells and/or their DNA was not detected. Also, when samples containing VNC cells mixed with dead cells were treated with flotation after storage at 4 or 20 degrees C for 21 days, a similar percentage resembling the VNC cell fraction was detected using real-time PCR and 5-cyano-2,3-ditolyl tetrazolium chloride-4',6'-diamidino-2-phenylindole staining (20% +/- 9% and 23% +/- 4%, respectively, at 4 degrees C; 11% +/- 4% and 10% +/- 2%, respectively, at 20 degrees C). This indicated that viable and VNC Campylobacter cells could be positively selected and quantified using the flotation method.

  3. Selective reduction of arsenic species by hydride generation - atomic absorption spectrometry. Part 2 - sample storage and arsenic determination in natural waters

    Directory of Open Access Journals (Sweden)

    Quináia Sueli P.

    2001-01-01

    Full Text Available Total arsenic, arsenite, arsinate and dimethylarsinic acid (DMA were selectively determined in natural waters by hydride generation - atomic absorption spectrometry, using sodium tetrahydroborate(III as reductant but in different reduction media. River water samples from the north region of Paraná State, Brazil, were analysed and showed arsenate as the principal arsenical form. Detection limits found for As(III (citrate buffer, As(III + DMA (acetic acid and As(III + As(V (hydrochloric acid were 0.6, 1.1 and 0.5 mg As L-1, respectively. Sample storage on the proper reaction media revealed to be a useful way to preserve the water sample.

  4. Using forbidden ordinal patterns to detect determinism in irregularly sampled time series.

    Science.gov (United States)

    Kulp, C W; Chobot, J M; Niskala, B J; Needhammer, C J

    2016-02-01

    It is known that when symbolizing a time series into ordinal patterns using the Bandt-Pompe (BP) methodology, there will be ordinal patterns called forbidden patterns that do not occur in a deterministic series. The existence of forbidden patterns can be used to identify deterministic dynamics. In this paper, the ability to use forbidden patterns to detect determinism in irregularly sampled time series is tested on data generated from a continuous model system. The study is done in three parts. First, the effects of sampling time on the number of forbidden patterns are studied on regularly sampled time series. The next two parts focus on two types of irregular-sampling, missing data and timing jitter. It is shown that forbidden patterns can be used to detect determinism in irregularly sampled time series for low degrees of sampling irregularity (as defined in the paper). In addition, comments are made about the appropriateness of using the BP methodology to symbolize irregularly sampled time series.

  5. A protocol for storage and long-distance shipment of Mediterranean fruit fly (Diptera: Tephritidae) eggs. 1. Effect of temperature, embryo age , and storage time on survival and quality

    International Nuclear Information System (INIS)

    Caceres, C.; Wornoayporn, V.; Islam, S.M.; Ahmad, S.; Ramirez, E.

    2007-01-01

    The operational use of Mediterranean fruit fly (medfly) Ceratitis capitata (Wiedemann), genetic sexing strains in Sterile Insect Technique applications can be maximized by developing methods for effective shipment of eggs. This would enable a central production facility to maintain the relevant mother stocks and large colonies to supply eggs to satellite centers that would mass produce only males for irradiation and release. In order to achieve this, the survival of medfly embryos of different ages was assessed after storage at 5, 10, 15, 20, and 25 deg. C in water for different periods of time. Survival was affected by all 3 variables, i.e., embryo age, water temperature, and length of storage. Storage of embryos at any temperature for 120 h resulted in almost no survival. Controlling the age of the embryo at the time of the temperature treatment is crucial for the success of this procedure. Embryos collected between 0 to 12 h after oviposition and pre-incubated at 25 deg. C for 12 h provide a suitable 72 h window for shipment when maintained between 10 to 15 deg. C. Under these conditions, no significant reductions in survival during all the developmental stages were observed. (author) [es

  6. Technical study gas storage. Final report

    International Nuclear Information System (INIS)

    Borowka, J.; Moeller, A.; Zander, W.; Koischwitz, M.A.

    2001-01-01

    This study will answer the following questions: (a) For what uses was the storage facility designed and for what use is it currently applied? Provide an overview of the technical data per gas storage facility: for instance, what is its capacity, volume, start-up time, etc.; (b) How often has this facility been used during the past 10 years? With what purpose was the facility brought into operation at the time? How much gas was supplied at the time from the storage facility?; (c) Given the characteristics and the use of the storage facility during the past 10 years and projected gas consumption in the future, how will the storage facility be used in the future?; (d) Are there other uses for which the gas storage facility can be deployed, or can a single facility be deployed for numerous uses? What are the technical possibilities in such cases? Questions (a) and (b) are answered separately for every storage facility. Questions (c) and (d) in a single chapter each (Chapter 2 and 3). An overview of the relevant storage data relating to current use, use in the last 10 years and use in future is given in the Annex

  7. Effect of slaughter methods on the quality of Chilean jack mackerel (Trachurus murphyi) during refrigerated storage.

    Science.gov (United States)

    Lyu, Fei; Huang, Rui-Ji; Liu, Lin; Zhou, Xuxia; Ding, Yu-Ting

    2015-03-01

    The main objective of this study was to assess the influence of slaughter methods on the quality of Chilean jack mackerel (Trachurus murphyi) during refrigerated storage on board. Fishes were slaughtered by asphyxia in air (AA), asphyxia in ice water (AI) or stunning fish heads (SH), and the rigor mortis, pH, total volatile basic nitrogen (TVB-N), trimethylamine (TMA), 2-thiobarbituric acid reactive substances (TBARS) and sensory properties for the fishes were analyzed. On day 0, Chilean jack mackerel samples of AI group displayed higher pH values than those of AA and SH groups. TVB-N, TMA and TBARS values of all samples increased with the storage time, and these values of AI had a lower increase than AA and SH. Moreover, samples of AI had a better sensory score than AA and SH during storage. It can be concluded that slaughter method of asphyxia in ice water for Chilean jack mackerel exhibit the better efficiency on maintaining the fish quality during refrigerated storage on board.

  8. Effect of processing and storage time on the contents of organosulfur compounds in pickled blanched garlic.

    Science.gov (United States)

    Beato, Victor Manuel; Sánchez, Antonio Higinio; de Castro, Antonio; Montaño, Alfredo

    2012-04-04

    The influence of processing, with and without fermentation, on the contents of organosulfur compounds, namely, γ-glutamyl peptides, S-alk(en)yl-L-cysteine sulfoxides (ACSOs), and S-allyl-L-cysteine (SAC), in pickled blanched garlic was evaluated. For each processing type, the effect of the preservation method and storage time was also analyzed. Blanching in hot water (90 °C for 5 min) hardly affected the individual organosulfur compound content. The fermentation and packing steps negatively affected the levels of all compounds except for SAC. The content of this compound increased during storage at room temperature whereas γ-glutamyl peptides and ACSOs were degraded to various extents. The pasteurization treatment itself had no significant effect on the concentrations of organosulfur compounds. Use of the corresponding fermentation brine in the case of the fermented product in conjunction with refrigerated storage was found to be the best method to preserve the levels of organosulfur compounds in pickled garlic stored for up to one year.

  9. Synthesis long life storage studies surface storage of vitrified wastes

    International Nuclear Information System (INIS)

    Beziat, A.; Breton, E.; Ranc, G.; Gaillard, J.P.; Lagrave, H.; Hollender, F.; Jourdain, F.; Piault, E.; Garnier, J.; Lamare, V.; Duret, B.; Helie, M.; Ferry, C.; Mijuin, D.; Gagnier, E.

    2004-01-01

    This document is realized in the framework of the axis 3 of the law of 1991 on the radioactive wastes management. It justifies the choices concerning long time surface storage installation of vitrified wastes, called high activity wastes. The long time of the installation would reach 300 years at the maximum. These wastes represent 1 % at the maximum, of radioactive wastes in France but 95 % of the whole radioactivity. Three main objectives were followed: provide a permanent containment of radionuclides; give the possibility of wastes containers retrieval at all the time; minimize the maintenance and the control. The results allow to conclude that the long time surface storage of high activity wastes is feasible. (A.L.B.)

  10. Storage duration effect on deformation recovery of repacked alginates

    Directory of Open Access Journals (Sweden)

    Siti Sunarintyas

    2009-09-01

    Full Text Available Background: Manufacturers supply alginate impression materials as a powder that is packaged in bulk and in individual container. Some Indonesian dental suppliers often repackage the bulk alginate into individual plastic packages which are not tied tightly and stored in the display room without air conditioner. It is known that critical factors to the shelf life of alginate includer avoidance of moisture contamination which may lead to premature setting of the alginate and avoidance of high temperature which may cause depolymerization of the alginate. Purpose: The aim of this study was to determine storage duration effect of repacked alginates on deformation recovery. Methods: Two brands of alginates (Tulip®TU, and Aroma Fine DF III®AF were repacked into 120 plastic containers. The samples were stored in room condition (temperature 29° C ± 1° C, relative humidity 60% ± 10% for 1, 2, 3, 4 and 5 weeks. The alginates setting time and recovery from deformation were measured according to the ANSI/ADA specification number 18 (ISO 1563. result: The results revealed that there was decreased setting time during 5 weeks but there was slight decreased in deformation recovery after 3 weeks storage. The ANOVA showed there was no significant difference of alginates deformation recovery among the storage times (p > 0.05. Conclusion: Storage duration of repacked alginates in plastic containers during 5 weeks in room condition do not influence the alginate deformation recovery.

  11. Effects of storage and gamma irradiation on (japonica) waxy rice

    International Nuclear Information System (INIS)

    Sung, W.-C.; Hong, Mei-Chu; Chang, T.-S.

    2008-01-01

    Japonica cultivar, Taichung waxy 70 (TCW 70), was exposed to gamma radiation with doses ranging from 0 to 2.0 kGy. The effects of gamma irradiation on waxy rice pasting properties and the qualities of its food product, mochi, were compared to the effects of storage over 12 months. Doses ranging from 0.5 to 2 kGy can decrease the paste viscosity of waxy rice as those obtained after 6 months of storage. Radiation treatments were less effective to decrease the hardness of mochi than waxy rice samples stored over 6 months. It was shown the effects of gamma irradiation on shortening the japonica waxy rice aging time and improving the quality of rice products, like mochi, were not as good as the effects of storage

  12. Effects of storage and gamma irradiation on (japonica) waxy rice

    Energy Technology Data Exchange (ETDEWEB)

    Sung, W.-C. [Department of Hotel and Restaurant Management, Chia Nan University of Pharmacy and Science, 60 Erh-Jen Road, Sec. 1, Pao-An, Jen-Te Hsiang, Tainan 717, Taiwan (China)], E-mail: sungwilliam2001@yahoo.com.tw; Hong, Mei-Chu [TaiChung District Agricultural Research and Extension Station Council of Agriculture Executive Yuan, Taichung, Taiwan (China); Chang, T.-S. [Department of Biological Sciences and Technology, National University of Tainan, Tainan, Taiwan (China)

    2008-01-15

    Japonica cultivar, Taichung waxy 70 (TCW 70), was exposed to gamma radiation with doses ranging from 0 to 2.0 kGy. The effects of gamma irradiation on waxy rice pasting properties and the qualities of its food product, mochi, were compared to the effects of storage over 12 months. Doses ranging from 0.5 to 2 kGy can decrease the paste viscosity of waxy rice as those obtained after 6 months of storage. Radiation treatments were less effective to decrease the hardness of mochi than waxy rice samples stored over 6 months. It was shown the effects of gamma irradiation on shortening the japonica waxy rice aging time and improving the quality of rice products, like mochi, were not as good as the effects of storage.

  13. HASE - The Helsinki adaptive sample preparation line

    Energy Technology Data Exchange (ETDEWEB)

    Palonen, V., E-mail: vesa.palonen@helsinki.fi [Department of Physics, University of Helsinki, P.O. Box 43, FI-00014 (Finland); Pesonen, A. [Laboratory of Chronology, Finnish Museum of Natural History, P.O. Box 64, FI-00014 (Finland); Herranen, T.; Tikkanen, P. [Department of Physics, University of Helsinki, P.O. Box 43, FI-00014 (Finland); Oinonen, M. [Laboratory of Chronology, Finnish Museum of Natural History, P.O. Box 64, FI-00014 (Finland)

    2013-01-15

    We have designed and built an adaptive sample preparation line with separate modules for combustion, molecular sieve handling, CO{sub 2} gas cleaning, CO{sub 2} storage, and graphitization. The line is also connected to an elemental analyzer. Operation of the vacuum equipment, a flow controller, pressure sensors, ovens, and graphitization reactors are automated with a reliable NI-cRIO real-time system. Stepped combustion can be performed in two ovens at temperatures up to 900 Degree-Sign C. Depending on the application, CuO or O{sub 2}-flow combustion can be used. A flow controller is used to adjust the O{sub 2} flow and pressure during combustion. For environmental samples, a module for molecular sieve regeneration and sample desorption is attached to the line replacing the combustion module. In the storage module, CO{sub 2} samples can be stored behind a gas-tight diaphragm valve and either stored for later graphitization or taken for measurements with separate equipment (AMS gas ion source or a separate mass spectrometer). The graphitization module consists of four automated reactors, capable of graphitizing samples with masses from 3 mg down to 50 {mu}g.

  14. Effect of storage time of extended-pour and conventional alginate impressions on dimensional accuracy of casts.

    Directory of Open Access Journals (Sweden)

    Ahmad Rohanian

    2014-12-01

    Full Text Available Some manufacturers claim to have produced new irreversible hydro-colloids that are able to maintain their dimensional stability during storage. The present study evaluated the effect of storage time on dimensional stability of three alginates: Hydrogum 5, Tropicalgin and Alginoplast.In this experimental in-vitro trial, a total of 90 alginate impressions were made from a Dentoform model using Hydrogum 5, Tropicalgin and Alginoplast alginates. The impressions were stored in a sealed plastic bag without a damp paper towel for 0, 24, 48, 72 and 120 hours and then poured with type III dental stone. Cross-arch (facial of 6 to facial of 6 on the opposite side and antero-posterior (distal of right first molar to the ipsilateral central incisor measurements were made with a digital caliper on the casts. Data were analyzed by two-way and one-way ANOVA and Tukey's post-hoc test (P<0.05.Alginate type and the pouring time significantly affected the dimensional stability of alginate impressions (both Ps<0.001. Pouring of Hydrogum 5 impressions can be delayed for up to 120 hours without significant dimensional changes. Alginoplast impressions may be poured after 72 hours, but Tropicalgin should be poured immediately and the storage time should not be more than 24 hours.Immediate pouring of alginate impressions provides the highest accuracy in reproducing the teeth and adjacent tissues; however, this study demonstrated that pouring may be delayed for up to five days using extended-pour (Hydrogum 5 alginates.

  15. Effects of Agitation and Storage Temperature on Measurements of Hydration Status.

    Science.gov (United States)

    Adams, Heather M; Eberman, Lindsey E; Yeargin, Susan W; Niemann, Andrew J; Mata, Heather L; Dziedzicki, David J

    2015-12-01

    Hypohydration can have significant implications on normal physiological functions of the body. This study aimed to determine the impact of agitation, storage temperature, and storage time on urine osmolality compared to the criterion control. We used a descriptive diagnostic validity test design. To investigate agitation, we recruited 75 healthy individuals (males = 41, females = 34; mean age = 22 ± 5 years; mean self-reported height = 172 ± 23 cm and mass = 77 ± 17 kg) who provided one or more samples (total = 81). The independent variables were agitation (vortex, hand shaken, no agitation) and temperature (room temperature, freezer, and refrigerator) type. Participants completed informed consent, a health questionnaire and were asked to provide a urine sample, which was split and labeled according to agitation type or storage temperature. Urine osmolality was used to determine hydration status at two time points (within 2 hours [control], 48 hours). We used t-tests to determine the difference between each condition and the control and calculated percent error for each condition. No significant differences for no agitation (t79 = -0.079, P = 0.937), hand shaken (t79 = 1.395, P = 0.167) or vortex mixed (t79 = -0.753, P = 0.453) were identified when compared to the criterion control. No significant differences for room temperature (t82 = -0.720, P = 0.474), refrigerator (t82 = -2.697, P = 0.008) or freezer (t82 = 2.576, P = 0.012) were identified when compared to the criterion control. Our findings suggest agitation of urine specimen is not necessary and samples do not require refrigeration or freezing if assessed within 48 hours. Analysis within two hours of collection is not necessary and samples can be stored for up to 48 hours without impacting the hydration status of the sample.

  16. Optimum community energy storage system for PV energy time-shift

    International Nuclear Information System (INIS)

    Parra, David; Gillott, Mark; Norman, Stuart A.; Walker, Gavin S.

    2015-01-01

    Highlights: • The performance and economic benefits of Pb-acid and Li-ion batteries are compared. • The business case during the decarbonisation pathway is assessed. • The aggregation from a community approach reduced the levelised cost by 37% by 2020. • For a forecast price of 16.3 p/kW h Li-ion battery cost must be less than 275 £/kW h. • A 10% subsidy will be needed for Li-ion batteries to achieve the 2020 forecast. - Abstract: A novel method has been designed to obtain the optimum community energy storage (CES) systems for end user applications. The method evaluates the optimum performance (including the round trip efficiency and annual discharge), levelised cost (LCOES), the internal rate of return and the levelised value of suitable energy storage technologies. A complimentary methodology was developed including three reference years (2012, 2020 and zero carbon year) to show the evolution of the business case during the low carbon transition. The method follows a community approach and the optimum CES system was calculated as a function of the size of the community. In this work, this method was put in practice with lead-acid (PbA) and lithium-ion battery (Li-ion) technologies when performing PV energy time-shift using real demand data from a single home to a 100-home community. The community approach reduced the LCOES down to 0.30 £/kW h and 0.11 £/kW h in 2020 and the zero carbon year respectively. These values meant a cost reduction by 37% and 66% regarding a single home. Results demonstrated that PbA batteries needs from 1.5 to 2.5 times more capacity than Li-ion chemistry to reduce the LCOES, the worst case scenario being for the smallest communities, because the more spiky demand profile required proportionately larger PbA battery capacities

  17. Quality assurance in the pre-analytical phase of human urine samples by (1)H NMR spectroscopy.

    Science.gov (United States)

    Budde, Kathrin; Gök, Ömer-Necmi; Pietzner, Maik; Meisinger, Christine; Leitzmann, Michael; Nauck, Matthias; Köttgen, Anna; Friedrich, Nele

    2016-01-01

    Metabolomic approaches investigate changes in metabolite profiles, which may reflect changes in metabolic pathways and provide information correlated with a specific biological process or pathophysiology. High-resolution (1)H NMR spectroscopy is used to identify metabolites in biofluids and tissue samples qualitatively and quantitatively. This pre-analytical study evaluated the effects of storage time and temperature on (1)H NMR spectra from human urine in two settings. Firstly, to evaluate short time effects probably due to acute delay in sample handling and secondly, the effect of prolonged storage up to one month to find markers of sample miss-handling. A number of statistical procedures were used to assess the differences between samples stored under different conditions, including Projection to Latent Structure Discriminant Analysis (PLS-DA), non-parametric testing as well as mixed effect linear regression analysis. The results indicate that human urine samples can be stored at 10 °C for 24 h or at -80 °C for 1 month, as no relevant changes in (1)H NMR fingerprints were observed during these time periods and temperature conditions. However, some metabolites most likely of microbial origin showed alterations during prolonged storage but without facilitating classification. In conclusion, the presented protocol for urine sample handling and semi-automatic metabolite quantification is suitable for large-scale epidemiological studies. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. EVALUATION OF THE EFFECT OF SPUTUM STORAGE CONDITIONS ON THE VITAL PROPERTIES OF TUBERCULOUS MYCOBACTERIA

    Directory of Open Access Journals (Sweden)

    Yu. D. Rodionova

    2017-01-01

    Full Text Available Goal of the study: to enhance efficiency of laboratory diagnostics of tuberculous infection through investigating the effect of various storage conditions of samples on the growth properties of Tuberculosis complex mycobacteria.Materials and Methods. 2058 samples of sputum collected by coughing were examined. All sputum samples were aliquoted into 5 parts stored under various conditions: in the fridge under +7°С for 2 hours; frozen for 7 days; by room indoor temperature for 48-72 hours; with the use preservative 10% solution of triple-substituted natrium phosphate for 48 hours; in the fridge under +7°С for 2 hours with consequent treatment by 1% solution of N-acetyl-L-cysteine.Results. The most optimal sputum storage conditions are freezing by -20°С, providing maximum safety of mycobacteria and minimum contamination of the samples with foreign bacteria. Sputum storage by indoor room temperature for 2-3 days reduces the number of positive results of cultures on nutritive media. Using 10% solution of triple-substituted natrium phosphate provides high positive results of bacterioscopic and cultural testing techniques. Time prolongation for biomaterials storage in the preservative solution for more than 72 hours results in the death tuberculous mycobacteria. 

  19. INAA applied to halogen (Br and I) stability in long-term storage of lyophilized biological materials

    International Nuclear Information System (INIS)

    Zaichick, V.; Zaichick, S.

    2000-01-01

    Instrumental neutron activation analysis (INAA) was used to determine the Br and I concentration in the same ten lyophilized and homogenized human thyroid samples prior and after a 20-year storage at room temperature. It was found that long-term storage had no effect on the iodine content. At the same time, the bromine content was about 2-fold lower (p<0.01). It was assumed that possible losses of other halogens can occur under long-term storage of lyophilized biological materials at room temperature. (author)

  20. Effect of sourdough addition and storage time on in vitro starch digestibility and estimated glycemic index of tef bread.

    Science.gov (United States)

    Shumoy, Habtu; Van Bockstaele, Filip; Devecioglu, Dilara; Raes, Katleen

    2018-10-30

    The effect of sourdough amount and storage time on starch digestibility and estimated glycemic index (eGI) of tef bread was investigated. The rapidly digestible starch (RDS), slowly digestible starch (SDS) and resistant starch (RS) of 0-30% sourdough fresh tef breads ranged from 49 to 58, 16 to 29 and 20 to 26 g/100 g starch, respectively. Storage of tef breads up to 5 days decreased the RDS by more than 2-fold while SDS and RS increased by 2 and 3 fold, respectively. The eGI for fresh and stored breads ranged from 39 to 89. Addition of sourdough increased the eGI of fresh breads while no uniform pattern was seen in the stored breads. As the storage time increased, all the breads showed a decrease in eGI. In vivo study is necessary to further investigate the effect of sourdough on GI of tef bread. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Effect of irradiation and storage on physico-chemical characteristics of garlic

    International Nuclear Information System (INIS)

    Wahid, M.; Mazullah; Khan, S.; Shah, A.H.

    1990-01-01

    Garlic bulbs (cv. G.S.I.) were irradiated at 0.05, 0.10, 0.15 or 0.20 kGy using 60 Co and stored in wooden crates for 4 months at ambient temperature (20-37°C, 50-80% RH) or low temperature (10°, 80-90% RH). Samples were monitored for sprouting, rot and weight loss. Consumer acceptability and acid value were determined throughout storage. Sprouting was apparent in control (non-irradiated) samples after 4 and 10 weeks' storage at low and ambient temperature, respectively, and reached 100 and 69% after 16 weeks' storage at low and ambient temperature, respectively. Irradiation inhibited sprouting at both temperatures. Percentage decay [unspecified] was lower in irradiated samples than in controls, which showed 31.7% and 52.9% decay, respectively, after 16 weeks' storage at ambient and low temperature. Weight loss increased from 0.2 to 28.3% and from 0.3 to 31.5% in control samples at low and ambient temperature, respectively, between 2 and 16 weeks' storage. Weight loss was less in irradiated samples. Sensory tests showed that irradiated samples retained colour, texture and odour compared with controls. There was a gradual and significant increase (from 0.448 to 2.246 mg KOH/100 g edible portion of sample) in the acid value of controls during storage. Lower doses of irradiation and storage temperature had an irregular effect on the acid value but the highest dose increased the acid value. It was concluded that irradiation had no deleterious effects on the storage properties of garlic and that a dose of 0.05 kGy could be considered cost-effective. (author)

  2. Method for Hot Real-Time Sampling of Gasification Products

    Energy Technology Data Exchange (ETDEWEB)

    Pomeroy, Marc D [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-29

    The Thermochemical Process Development Unit (TCPDU) at the National Renewable Energy Laboratory (NREL) is a highly instrumented half-ton/day pilot scale plant capable of demonstrating industrially relevant thermochemical technologies from lignocellulosic biomass conversion, including gasification. Gasification creates primarily Syngas (a mixture of Hydrogen and Carbon Monoxide) that can be utilized with synthesis catalysts to form transportation fuels and other valuable chemicals. Biomass derived gasification products are a very complex mixture of chemical components that typically contain Sulfur and Nitrogen species that can act as catalysis poisons for tar reforming and synthesis catalysts. Real-time hot online sampling techniques, such as Molecular Beam Mass Spectrometry (MBMS), and Gas Chromatographs with Sulfur and Nitrogen specific detectors can provide real-time analysis providing operational indicators for performance. Sampling typically requires coated sampling lines to minimize trace sulfur interactions with steel surfaces. Other materials used inline have also shown conversion of sulfur species into new components and must be minimized. Sample line Residence time within the sampling lines must also be kept to a minimum to reduce further reaction chemistries. Solids from ash and char contribute to plugging and must be filtered at temperature. Experience at NREL has shown several key factors to consider when designing and installing an analytical sampling system for biomass gasification products. They include minimizing sampling distance, effective filtering as close to source as possible, proper line sizing, proper line materials or coatings, even heating of all components, minimizing pressure drops, and additional filtering or traps after pressure drops.

  3. Effect of storage time of extended-pour and conventional alginate impressions on dimensional accuracy of casts.

    Science.gov (United States)

    Rohanian, Ahmad; Ommati Shabestari, Ghasem; Zeighami, Somayeh; Samadi, Mohammad Javad; Shamshiri, Ahmad Reza

    2014-11-01

    Some manufacturers claim to have produced new irreversible hydro-colloids that are able to maintain their dimensional stability during storage. The present study evaluated the effect of storage time on dimensional stability of three alginates: Hydrogum 5, Tropicalgin and Alginoplast. In this experimental in-vitro trial, a total of 90 alginate impressions were made from a Dentoform model using Hydrogum 5, Tropicalgin and Alginoplast alginates. The impressions were stored in a sealed plastic bag without a damp paper towel for 0, 24, 48, 72 and 120 hours and then poured with type III dental stone. Cross-arch (facial of 6 to facial of 6 on the opposite side) and antero-posterior (distal of right first molar to the ipsilateral central incisor) measurements were made with a digital caliper on the casts. Data were analyzed by two-way and one-way ANOVA and Tukey's post-hoc test (Pimpressions (both Psimpressions can be delayed for up to 120 hours without significant dimensional changes. Alginoplast impressions may be poured after 72 hours, but Tropicalgin should be poured immediately and the storage time should not be more than 24 hours. Immediate pouring of alginate impressions provides the highest accuracy in reproducing the teeth and adjacent tissues; however, this study demonstrated that pouring may be delayed for up to five days using extended-pour (Hydrogum 5) alginates.

  4. Study of the influence of storage conditions on the quality and migration levels of antimony in polyethylene terephthalate-bottled water.

    Science.gov (United States)

    Payán, Luis; Poyatos, M Teresa; Muñoz, Lucía; La Rubia, M Dolores; Pacheco, Rafael; Ramos, Natividad

    2017-06-01

    The main objectives of this study are to determine the presence of antimony in water stored in polyethylene terephthalate bottles and the influence of temperature and time over the migration levels. For this purpose, Sb determination was carried out in water at different experimental conditions: storage for one to three weeks at 25 to 80 ℃; long-term (six months) storage at room temperature between 16 and 24 ℃ and storage in car during summer which is a common consumer's habit. In addition, water quality analysis was developed after different time-temperature storage conditions. All the samples at the end of their storage conditions were analyzed by inductively coupled plasma mass spectrometry. The limit of detection and quantification were 0.50 and 0.80 µg/L, respectively. The results for the bottled water stored during six months indicated that the average Sb concentration was 0.332 ± 0.015 µg/L. This value is below the European maximum permissible migration level of 5 µg/L. With regard to the newly bottled water, no Sb was detected at the initial time for all temperatures studied. However, the Sb concentration in water increased with both time and temperature. The levels of Sb started exceeding the European limits when the samples were stored at 60 ℃ for two weeks.

  5. Ground-water sampling of the NNWSI (Nevada Nuclear Waste Storage Investigation) water table test wells surrounding Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Matuska, N.A.

    1988-12-01

    The US Geological Survey (USGS), as part of the Nevada Nuclear Waste Storage Investigation (NNWSI) study of the water table in the vicinity of Yucca Mountain, completed 16 test holes on the Nevada Test Site and Bureau of Land Management-administered lands surrounding Yucca Mountain. These 16 wells are monitored by the USGS for water-level data; however, they had not been sampled for ground-water chemistry or isotropic composition. As part of the review of the proposed Yucca Mountain high-level nuclear waste repository, the Desert Research Institute (DRI) sampled six of these wells. The goal of this sampling program was to measure field-dependent parameters of the water such as electrical conductivity, pH, temperature and dissolved oxygen, and to collect samples for major and minor element chemistry and isotopic analysis. This information will be used as part of a program to geochemically model the flow direction between the volcanic tuff aquifers and the underlying regional carbonate aquifer

  6. Influence of storage conditions on aluminum concentrations in serum, dialysis fluid, urine, and tap water.

    Science.gov (United States)

    Wilhelm, M; Ohnesorge, F K

    1990-01-01

    The influence of storage temperature, vessel type, and treatment on alterations of aluminum (Al) concentrations in serum, urine, and dialysis fluid samples was studied at three different concentrations for each sample over an 18-month period. Furthermore, the influence of acidification on Al levels in tap water, urine, and dialysis fluid samples was studied over a four-month period. Al was measured by atomic absorption spectrometry. Sample storage in glass vessels was unsuitable, whereas only minor alterations of Al levels were observed with storage in polypropylene tubes, polystyrene tubes, and Monovettes. By using appropriate plastic containers, acid washing of the vessels showed no improvement. Frozen storage was superior compared with 4 degrees C, whereas storage at -80 degrees C offered no advantage compared with storage at -20 degrees C. Acidification of tap water samples was necessary to stabilize Al levels during storage. No striking effect of acidification on Al levels in urine and dialysis fluid samples was found. It is concluded that longterm storage of serum, urine, tap water, and dialysis fluid samples is possible if appropriate conditions are used.

  7. Effects of Pressure, Temperature, Treatment Time, and Storage on Rheological, Textural, and Structural Properties of Heat-Induced Chickpea Gels

    Directory of Open Access Journals (Sweden)

    María Dolores Alvarez

    2015-04-01

    Full Text Available Pressure-induced gelatinization of chickpea flour (CF was studied in combination with subsequent temperature-induced gelatinization. CF slurries (with 1:5 flour-to-water ratio and CF in powder form were treated with high hydrostatic pressure (HHP, temperature (T, and treatment time (t at three levels (200, 400, 600 MPa; 10, 25, 50 °C; 5, 15, 25 min. In order to investigate the effect of storage (S, half of the HHP-treated CF slurries were immediately analyzed for changes in oscillatory rheological properties under isothermal heating at 75 °C for 15 min followed by cooling to 25 °C. The other half of the HHP-treated CF slurries were refrigerated (at 4 °C for one week and subsequently analyzed for changes in oscillatory properties under the same heating conditions as the unrefrigerated samples. HHP-treated CF in powder form was analyzed for changes in textural properties of heat-induced CF gels under isothermal heating at 90 °C for 5 min and subsequent cooling to 25 °C. Structural changes during gelatinization were investigated using microscopy. Pressure had a more significant effect on rheological and textural properties, followed by T and treatment t (in that order. Gel aging in HHP-treated CF slurries during storage was supported by rheological measurements.

  8. Pulping Variables, Storage Time and Pitch Deposit | Ogunwusi ...

    African Journals Online (AJOL)

    Pulp resin is also influenced by effective alkali concentration of the pulping medium. With increase in effective alkali concentration from 13% to 15%, pulp pitch is reduced. The interaction effect of storage and effective alkali concentration was not significant indicating that reduction in pulp pitch caused by effective alkali ...

  9. Long-time dynamics of laser-cooled ions in the TSR storage ring

    International Nuclear Information System (INIS)

    Mudrich, M.

    2000-01-01

    This diploma thesis studies experimentally the long-time dynamics of laser-cooled 9 Be + -beams at the TSR under different cooling conditions. The goal is to enlarge the understanding of ultra-cold, non-neutral plasma at high center-of-mass energies. By means of improved measurement capabilities one can now for the first time monitor the entire phase-space over a long time. This makes it possible to quantitatively analyse the possibilities and limitations of laser cooling at a storage ring. Under optimum cooling conditions a regime of high phase-space density is reached, close to the region where influences of Coulomb coupling are expected. Furthermore, a Monte-Carlo model is worked out that qualitatively describes the beam dynamics. The model includes the influence of transverse-longitudinal coupling due to intra beam scattering on the longitudinal phase-space distribution. At high phase-space density a sudden disappearance of intra beam collisions is observed experimentally and possible interpretations are given. (orig.)

  10. Biogenic Amine Production in Olomouc Curd Cheese (Olomoucké tvarůžky at Various Storage Conditions

    Directory of Open Access Journals (Sweden)

    Eva Standarová

    2010-01-01

    Full Text Available The aim of this study was to evaluate the effects of temperature and storage time on the formation of biogenic amines (BAs in the traditional Czech curd cheese (Olomoucké tvarůžky. Samples were stored for 7 weeks at 5 °C and 20 °C. BAs were studied as dansyl derivatives by the RP-HPLC method with fluorescence detection, histamine was determined using a photodiode array detector. Physical and chemical properties were analyzed as specified by the Czech National Standard, as were the sensory characteristics (colour, odour, texture and flavour. The major amines found were cadaverine (124–2413 mg kg-1 and tyramine (117–1058 mg kg-1, followed by putrescine (75–767 mg kg-1 and histamine (74–411 mg kg-1. Low concentrations of tryptamine, spermine and spermidine were present. Total concentrations of BAs significantly increased with storage time (P P -1 at the end of storage. The toxicologically critical value of 900 mg kg-1 for the sum of histamine + tyramine + putrescine + cadaverine was reached 17 days later in the cheese stored at 5 °C compared to 20 °C. When stored at 5 °C, the samples retained adequate sensory characteristics for the entire safe storage time. The effects of storage conditions on BAs formation are relevant to reducing the risk associated with consumption of cheese high in BAs.

  11. Transformation-cost time-series method for analyzing irregularly sampled data.

    Science.gov (United States)

    Ozken, Ibrahim; Eroglu, Deniz; Stemler, Thomas; Marwan, Norbert; Bagci, G Baris; Kurths, Jürgen

    2015-06-01

    Irregular sampling of data sets is one of the challenges often encountered in time-series analysis, since traditional methods cannot be applied and the frequently used interpolation approach can corrupt the data and bias the subsequence analysis. Here we present the TrAnsformation-Cost Time-Series (TACTS) method, which allows us to analyze irregularly sampled data sets without degenerating the quality of the data set. Instead of using interpolation we consider time-series segments and determine how close they are to each other by determining the cost needed to transform one segment into the following one. Using a limited set of operations-with associated costs-to transform the time series segments, we determine a new time series, that is our transformation-cost time series. This cost time series is regularly sampled and can be analyzed using standard methods. While our main interest is the analysis of paleoclimate data, we develop our method using numerical examples like the logistic map and the Rössler oscillator. The numerical data allows us to test the stability of our method against noise and for different irregular samplings. In addition we provide guidance on how to choose the associated costs based on the time series at hand. The usefulness of the TACTS method is demonstrated using speleothem data from the Secret Cave in Borneo that is a good proxy for paleoclimatic variability in the monsoon activity around the maritime continent.

  12. Transformation-cost time-series method for analyzing irregularly sampled data

    Science.gov (United States)

    Ozken, Ibrahim; Eroglu, Deniz; Stemler, Thomas; Marwan, Norbert; Bagci, G. Baris; Kurths, Jürgen

    2015-06-01

    Irregular sampling of data sets is one of the challenges often encountered in time-series analysis, since traditional methods cannot be applied and the frequently used interpolation approach can corrupt the data and bias the subsequence analysis. Here we present the TrAnsformation-Cost Time-Series (TACTS) method, which allows us to analyze irregularly sampled data sets without degenerating the quality of the data set. Instead of using interpolation we consider time-series segments and determine how close they are to each other by determining the cost needed to transform one segment into the following one. Using a limited set of operations—with associated costs—to transform the time series segments, we determine a new time series, that is our transformation-cost time series. This cost time series is regularly sampled and can be analyzed using standard methods. While our main interest is the analysis of paleoclimate data, we develop our method using numerical examples like the logistic map and the Rössler oscillator. The numerical data allows us to test the stability of our method against noise and for different irregular samplings. In addition we provide guidance on how to choose the associated costs based on the time series at hand. The usefulness of the TACTS method is demonstrated using speleothem data from the Secret Cave in Borneo that is a good proxy for paleoclimatic variability in the monsoon activity around the maritime continent.

  13. A cryogenic electrostatic trap for long-time storage of keV ion beams

    Science.gov (United States)

    Lange, M.; Froese, M.; Menk, S.; Varju, J.; Bastert, R.; Blaum, K.; López-Urrutia, J. R. Crespo; Fellenberger, F.; Grieser, M.; von Hahn, R.; Heber, O.; Kühnel, K.-U.; Laux, F.; Orlov, D. A.; Rappaport, M. L.; Repnow, R.; Schröter, C. D.; Schwalm, D.; Shornikov, A.; Sieber, T.; Toker, Y.; Ullrich, J.; Wolf, A.; Zajfman, D.

    2010-05-01

    We report on the realization and operation of a fast ion beam trap of the linear electrostatic type employing liquid helium cooling to reach extremely low blackbody radiation temperature and residual gas density and, hence, long storage times of more than 5 min which are unprecedented for keV ion beams. Inside a beam pipe that can be cooled to temperatures <15 K, with 1.8 K reached in some locations, an ion beam pulse can be stored at kinetic energies of 2-20 keV between two electrostatic mirrors. Along with an overview of the cryogenic trap design, we present a measurement of the residual gas density inside the trap resulting in only 2×103 cm-3, which for a room temperature environment corresponds to a pressure in the 10-14 mbar range. The device, called the cryogenic trap for fast ion beams, is now being used to investigate molecules and clusters at low temperatures, but has also served as a design prototype for the cryogenic heavy-ion storage ring currently under construction at the Max-Planck Institute for Nuclear Physics.

  14. Is it acceptable to use coagulation plasma samples stored at room temperature and 4°C for 24 hours for additional prothrombin time, activated partial thromboplastin time, fibrinogen, antithrombin, and D-dimer testing?

    Science.gov (United States)

    Rimac, V; Coen Herak, D

    2017-10-01

    Coagulation laboratories are faced on daily basis with requests for additional testing in already analyzed fresh plasma samples. This prompted us to examine whether plasma samples stored at room temperature (RT), and 4°C for 24 hours can be accepted for additional prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen (Fbg), antithrombin (AT), and D-dimer testing. We measured PT, aPTT, Fbg in 50 and AT in 30 plasma samples with normal and pathological values, within 4 hours of blood collection (baseline results) and after 24-hours storage at RT (primary tubes), and 4°C (aliquots). D-dimer stability was investigated in 20 samples stored in primary tubes at 4°C. No statistically significant difference between baseline results and results in samples stored at RT and 4°C was observed for PT (P=.938), aPTT (P=.186), Fbg (P=.962), AT (P=.713), and D-dimers (P=.169). The highest median percentage changes were found for aPTT, being more pronounced for samples stored at 4°C (13.0%) than at RT (8.7%). Plasma samples stored both at RT and 4°C for 24 hours are acceptable for additional PT, Fbg, and AT testing. Plasma samples stored 24 hours in primary tubes at 4°C are suitable for D-dimer testing. © 2017 John Wiley & Sons Ltd.

  15. Custom sample environments at the ALBA XPEEM

    Energy Technology Data Exchange (ETDEWEB)

    Foerster, Michael, E-mail: mfoerster@cells.es; Prat, Jordi; Massana, Valenti; Gonzalez, Nahikari; Fontsere, Abel; Molas, Bernat; Matilla, Oscar; Pellegrin, Eric; Aballe, Lucia

    2016-12-15

    A variety of custom-built sample holders offer users a wide range of non-standard measurements at the ALBA synchrotron PhotoEmission Electron Microscope (PEEM) experimental station. Some of the salient features are: an ultrahigh vacuum (UHV) suitcase compatible with many offline deposition and characterization systems, built-in electromagnets for uni- or biaxial in-plane (IP) and out-of-plane (OOP) fields, as well as the combination of magnetic fields with electric fields or current injection. Electronics providing a synchronized sinusoidal signal for sample excitation enable time-resolved measurements at the 500 MHz storage ring RF frequency. - Highlights: • Custom sample environment for XPEEM at ALBA. • Sample holders with electromagnets, in-plane dipole, in-plane quadruple and out-of-plane. • Sample holders with printed circuit boards for electric contacts including electromagnets. • UHV suitcase adapter. • Synchronized 500 MHz electrical excitation for time resolved measurements.

  16. Transuranic Storage Area (TSA)-3 container storage unit RCRA closure plan

    International Nuclear Information System (INIS)

    Barry, G.A.; Lodman, D.L.; Spry, M.J.; Poor, K.J.

    1992-11-01

    This document describes the proposed plan for closure of the Transuranic Storage Area (TSA)-3 container storage unit at the Idaho National Engineering Laboratory in accordance with the Resource Conservation and Recovery Act closure requirements. The location, size, capacity, history, and current status of the unit are described. The unit will be closed by decontaminating structures and equipment that may have contacted waste. Sufficient sampling and documentation of all activities will be performed to demonstrate clean closure. A tentative schedule is provided in the form of a milestone chart

  17. Sampling and Timing: A Task for the Environmetal Process

    NARCIS (Netherlands)

    Hilderink, G.H.; Broenink, Johannes F.

    2003-01-01

    Sampling and timing is considered a responsibility of the environment of controller software. In this paper we will illustrate a concept whereby an environmental process and multi-way events play an important role in applying timing for untimed CSP software architectures. We use this timing concept

  18. A New Battery Energy Storage Charging/Discharging Scheme for Wind Power Producers in Real-Time Markets

    Directory of Open Access Journals (Sweden)

    Minh Y Nguyen

    2012-12-01

    Full Text Available Under a deregulated environment, wind power producers are subject to many regulation costs due to the intermittence of natural resources and the accuracy limits of existing prediction tools. This paper addresses the operation (charging/discharging problem of battery energy storage installed in a wind generation system in order to improve the value of wind power in the real-time market. Depending on the prediction of market prices and the probabilistic information of wind generation, wind power producers can schedule the battery energy storage for the next day in order to maximize the profit. In addition, by taking into account the expenses of using batteries, the proposed charging/discharging scheme is able to avoid the detrimental operation of battery energy storage which can lead to a significant reduction of battery lifetime, i.e., uneconomical operation. The problem is formulated in a dynamic programming framework and solved by a dynamic programming backward algorithm. The proposed scheme is then applied to the study cases, and the results of simulation show its effectiveness.

  19. Real-Time Dynamic Simulation of Korean Power Grid for Frequency Regulation Control by MW Battery Energy Storage System

    Directory of Open Access Journals (Sweden)

    Tae-Hwan Jin

    2016-12-01

    Full Text Available The aim of this study was to develop a real-time dynamic simulator of a power grid with power plant and battery model. The simulator was used to investigate the frequency control characteristics of a megawatt-scale high-capacity energy storage system connected to the electric power grid. In this study, a lithium-ion secondary battery was chosen as one of the batteries for a grid-connected model. The dynamics of the model was analysed in both steady and transient states. The frequency control system of the battery model plays a role in regulating the grid frequency by controlling the power of energy storage systems according to process variables and grid frequencies. The power grid model based on the current power network of South Korea, included power plants, substations and power demands. The power supply is classified by the type of turbine generator as thermal, nuclear, hydro power, pumped power storage, combined power plants, and batteries, including high-capacity energy storage systems rated for a maximum of 500 MW. This study deals with an installed capacity of 87.17 GW and peak load of 77.30 GW in the Korean power grid. For 24 hours of operation, the maximum and minimum power outputs were simulated as 61.59 GW and 46.32 GW, respectively. The commercialized real-time dynamic simulation software ProTRAX was used. The simulation was conducted to observe the operation characteristics of the frequency control system during a breakdown of power plants, as well as under governor-free operation, auto generation control operation, and with the battery energy storage system connected. The results show that the model is valid for each power plant breakdown simulation. They also confirm that the output power and frequency controls of the battery operated well during simulations.

  20. Effect of cement/wood ratios and wood storage conditions on hydration temperature, hydration time, and compressive strength of wood-cement mixtures

    Science.gov (United States)

    Andy W.C. Lee; Zhongli Hong; Douglas R. Phillips; Chung-Yun Hse

    1987-01-01

    This study investigated the effect of cement/wood ratios and wood storage conditions on hydration temperature, hydration time, and compressive strength of wood-cement mixtures made from six wood species: southern pine, white oak, southern red oak, yellow-poplar, sweetgum, and hickory. Cement/wood ratios varied from 13/1 to 4/1. Wood storage conditions consisted of air-...

  1. The influence of freezer storage of urine samples on the BONN-Risk-Index for calcium oxalate crystallization.

    Science.gov (United States)

    Laube, Norbert; Zimmermann, Diana J

    2004-01-01

    This study was performed to quantify the effect of a 1-week freezer storage of urine on its calcium oxalate crystallization risk. Calcium oxalate is the most common urinary stone material observed in urolithiasis patients in western and affluent countries. The BONN-Risk-Index of calcium oxalate crystallization risk in human urine is determined from a crystallization experiment performed on untreated native urine samples. We tested the influence of a 1-week freezing on the BONN-Risk-Index value as well as the effect of the sample freezing on the urinary osmolality. In vitro crystallization experiments in 49 native urine samples from stone-forming and non-stone forming individuals were performed in order to determine their calcium oxalate crystallization risk according to the BONN-Risk-Index approach. Comparison of the results derived from original sample investigations with those obtained from the thawed aliquots by statistical evaluation shows that i) no significant deviation from linearity between both results exists and ii) both results are identical by statistical means. This is valid for both, the BONN-Risk-Index and the osmolality data. The differences in the BONN-Risk-Index results of both procedures of BONN-Risk-Index determination, however, exceed the clinically acceptable difference. Thus, determination of the urinary calcium oxalate crystallization risk from thawed urine samples cannot be recommended.

  2. Effect of storage time and framework design on the accuracy of maxillary cobalt-chromium cast removable partial dentures

    Science.gov (United States)

    Viswambaran, M.; Sundaram, R. K.

    2015-01-01

    Statement of Problem: Inaccuracies in the fit of palatal major connectors may be related to distortion of the wax pattern due to prolonged storage time and faulty major connector design. Purpose: This in vitro study was carried out to find out the effect of storage time and major connector design on the accuracy of cobalt-chromium cast removable partial dentures (RPDs). Materials and Methods: A brass metal die with a Kennedy Class III, modification 1, the partially edentulous arch was used as a master die. Thirty-six refractory casts were fabricated from the master die. The refractory casts were divided into three groups (Group I: Anterior-posterior palatal bar, Group II: Palatal strap and Group III: Palatal plate) based on the design of maxillary major connector and subdivided into four groups (sub Group A: 01 h, sub Group B: 03 h, Sub Group C: 06 h, and sub Group D: 24 h) based on the storage time. For each group, 12 frameworks were fabricated. The influence of wax pattern storage time and the accuracy of the fit palatal major connector designs on the master die were compared. Casting defects (nodules/incompleteness) of the frameworks were also evaluated before finishing and polishing. Repeated measures analysis of variance was used to analyze the data. Results: The gap discrepancy was least in sub Group A (01 h) followed by sub Group B (03 h) and C (06 h) and most in sub Group D (24 h). Statistically significant differences (P < 0.05 in all locations L1–L5) in the fit of the framework were related to the design of the major connector. The gap discrepancy was least in Group I (anterior-posterior palatal bar) followed by Group II (palatal strap) and most in Group II (palatal plate). Conclusions: It is recommended that the wax patterns for RPD to be invested immediately on completion of the wax procedure. The selection of a major connector design is crucial for an accurate fit of RPD. PMID:26681850

  3. Effect of storage time and framework design on the accuracy of maxillary cobalt-chromium cast removable partial dentures

    Directory of Open Access Journals (Sweden)

    M Viswambaran

    2015-01-01

    Full Text Available Statement of Problem: Inaccuracies in the fit of palatal major connectors may be related to distortion of the wax pattern due to prolonged storage time and faulty major connector design. Purpose: This in vitro study was carried out to find out the effect of storage time and major connector design on the accuracy of cobalt-chromium cast removable partial dentures (RPDs. Materials and Methods: A brass metal die with a Kennedy Class III, modification 1, the partially edentulous arch was used as a master die. Thirty-six refractory casts were fabricated from the master die. The refractory casts were divided into three groups (Group I: Anterior-posterior palatal bar, Group II: Palatal strap and Group III: Palatal plate based on the design of maxillary major connector and subdivided into four groups (sub Group A: 01 h, sub Group B: 03 h, Sub Group C: 06 h, and sub Group D: 24 h based on the storage time. For each group, 12 frameworks were fabricated. The influence of wax pattern storage time and the accuracy of the fit palatal major connector designs on the master die were compared. Casting defects (nodules/incompleteness of the frameworks were also evaluated before finishing and polishing. Repeated measures analysis of variance was used to analyze the data. Results: The gap discrepancy was least in sub Group A (01 h followed by sub Group B (03 h and C (06 h and most in sub Group D (24 h. Statistically significant differences (P < 0.05 in all locations L1–L5 in the fit of the framework were related to the design of the major connector. The gap discrepancy was least in Group I (anterior-posterior palatal bar followed by Group II (palatal strap and most in Group II (palatal plate. Conclusions: It is recommended that the wax patterns for RPD to be invested immediately on completion of the wax procedure. The selection of a major connector design is crucial for an accurate fit of RPD.

  4. Maintaining continuity of knowledge on safeguards samples

    International Nuclear Information System (INIS)

    Franssen, F.; Islam, A.B.M.N.; Sonnier, C.; Schoeneman, J.L.; Baumann, M.

    1992-01-01

    The conclusions of the vulnerability test on VOPAN (verification of Operator's Analysis) as conducted at Safeguards Analytical Laboratory (ASA) at Seibersdorf, Austria in October 1990 and documented in STR-266, indicate that ''whenever samples are taken for safeguards purposes extreme care must be taken to ensure that they have not been interfered with during the sample taking, transportation, storage or sample preparation process.'' Indeed there exist a number of possibilities to alter the content of a safeguards sample vial from the moment of sampling up to the arrival of the treated (or untreated) sample at SAL. The time lapse between these two events can range from a few days up to months. The sample history over this period can be subdivided into three main sub-periods: (1) the period from when the sampling activities are commenced up to the treatment in the operator's laboratory, (2) during treatment of samples in the operator's laboratory, and finally, (3) the period between that treatment and the arrival of the sample at SAL. A combined effort between the Agency and the United States Support Program to the Agency (POTAS) has resulted in two active tasks and one proposed task to investigate improving the maintenance of continuity of knowledge on safeguards samples during the entire period of their existence. This paper describes the use of the Sample Vial Secure Container (SVSC), of the Authenticated Secure Container System (ASCS), and of the Secure Container for Storage and Transportation of samples (SCST) to guarantee that a representative portion of the solution sample will be received at SAL

  5. On the Traceability of Commercial Saffron Samples Using 1H-NMR and FT-IR Metabolomics

    Directory of Open Access Journals (Sweden)

    Roberto Consonni

    2016-02-01

    Full Text Available In previous works on authentic samples of saffron of known history (harvest and processing year, storage conditions, and length of time some biomarkers were proposed using both FT-IR and NMR metabolomics regarding the shelf life of the product. This work addresses the difficulties to trace back the “age” of commercial saffron samples of unknown history, sets a limit value above which these products can be considered substandard, and offers a useful tool to combat saffron mislabeling and fraud with low-quality saffron material. Investigations of authentic and commercial saffron samples of different origin and harvest year, which had been stored under controlled conditions for different lengths of time, allowed a clear-cut clustering of samples in two groups according to the storage period irrespectively of the provenience. In this respect, the four-year cut off point proposed in our previous work assisted to trace back the “age” of unknown samples and to check for possible mislabeling practices.

  6. Storage in alluvial deposits controls the timing of particle delivery from large watersheds, filtering upland erosional signals and delaying benefits from watershed best management practices

    Science.gov (United States)

    Pizzuto, J. E.; Skalak, K.; Karwan, D. L.

    2017-12-01

    Transport of suspended sediment and sediment-borne constituents (here termed fluvial particles) through large river systems can be significantly influenced by episodic storage in floodplains and other alluvial deposits. Geomorphologists quantify the importance of storage using sediment budgets, but these data alone are insufficient to determine how storage influences the routing of fluvial particles through river corridors across large spatial scales. For steady state systems, models that combine sediment budget data with "waiting time distributions" (to define how long deposited particles remain stored until being remobilized) and velocities during transport events can provide useful predictions. Limited field data suggest that waiting time distributions are well represented by power laws, extending from 104 years, while the probability of storage defined by sediment budgets varies from 0.1 km-1 for small drainage basins to 0.001 km-1 for the world's largest watersheds. Timescales of particle delivery from large watersheds are determined by storage rather than by transport processes, with most particles requiring 102 -104 years to reach the basin outlet. These predictions suggest that erosional "signals" induced by climate change, tectonics, or anthropogenic activity will be transformed by storage before delivery to the outlets of large watersheds. In particular, best management practices (BMPs) implemented in upland source areas, designed to reduce the loading of fluvial particles to estuarine receiving waters, will not achieve their intended benefits for centuries (or longer). For transient systems, waiting time distributions cannot be constant, but will vary as portions of transient sediment "pulses" enter and are later released from storage. The delivery of sediment pulses under transient conditions can be predicted by adopting the hypothesis that the probability of erosion of stored particles will decrease with increasing "age" (where age is defined as the

  7. Monitoring plan for routine organic air emissions at the Radioactive Waste Management Complex Waste Storage Facilities

    International Nuclear Information System (INIS)

    Galloway, K.J.; Jolley, J.G.

    1994-06-01

    This monitoring plan provides the information necessary to perform routine organic air emissions monitoring at the Waste Storage Facilities located at the Transuranic Storage Area of the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. The Waste Storage Facilities include both the Type I and II Waste Storage Modules. The plan implements a dual method approach where two dissimilar analytical methodologies, Open-Path Fourier Transform Infrared Spectroscopy (OP-FTIR) and ancillary SUMMA reg-sign canister sampling, following the US Environmental Protection Agency (EPA) analytical method TO-14, will be used to provide qualitative and quantitative volatile organic concentration data. The Open-Path Fourier Transform Infrared Spectroscopy will provide in situ, real time monitoring of volatile organic compound concentrations in the ambient air of the Waste Storage Facilities. To supplement the OP-FTIR data, air samples will be collected using SUMMA reg-sign, passivated, stainless steel canisters, following the EPA Method TO-14. These samples will be analyzed for volatile organic compounds with gas chromatograph/mass spectrometry analysis. The sampling strategy, procedures, and schedules are included in this monitoring plan. The development of this monitoring plan is driven by regulatory compliance to the Resource Conservation and Recovery Act, State of Idaho Toxic Air Pollutant increments, Occupational Safety and Health Administration. The various state and federal regulations address the characterization of the volatile organic compounds and the resultant ambient air emissions that may originate from facilities involved in industrial production and/or waste management activities

  8. Different types of intermediate storages

    International Nuclear Information System (INIS)

    Spilker, H.

    1982-01-01

    Spent nuclear fuel elements require a period of ''cooling'' after withdrawal from a nuclear reactor. This is done in water storage pools located at the reactor facility. The minimum storage time prior to subsequent operations with the spent fuel is recognized as six to twelve months. After the initial storage period for cooling, the subsequent storage time in water pools could vary from a few years to several decades. Up to 1980, about 15.700 MTHM of spent LWR and HWR fuel have been discharged from nuclear stations. Since only a small fraction thereof has been already reprocessed. The spent fuel assemblies are stored at the reactor-side (AR) in reactor basins in normal or compact racks and away from reactor (AFR) in water pool storages awaiting either reprocessing or final disposal depending on the fuel cycle concept chosen by the individual countries. (orig.)

  9. Development project of an automatic sampling system for part time unmanned pipeline terminals

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Gullherme O.; De Almelda, Marcio M. G.; Ramos, Ricardo R. [Petrobas, (Brazil); Potten, Gary [Cameron Measurement Systems, (United States)

    2010-07-01

    The Sao Paulo - Brasilia Pipeline (OSBRA) is a highly automated pipeline using a SCADA system which operates from a control room. A new quality management system standard was established for transportation and storage operations. The products had to be sampled on an automatic basis. This paper reports the development of an automatic sampling system (ASS) in accordance with the new quality control standard. The prototype was developed to be implemented through a human-machine interface (HMI) from the control room SCADA screens. A technical cooperation agreement(TCA) was drawn up for development of this new ASS product. The TCA was a joint cooperation between the Holding, the Operator and the cooperators. The prototype will be on-field tested at Senador Canedo tank farm to SPEC requirements. The current performance of the ASS establishes reasonable expectations for further successful development.

  10. High resolution isotope data and ensemble modelling reveal ecohydrological controls on catchment storage-discharge relationships and flux travel time distributions

    Science.gov (United States)

    Soulsby, C.; Kuppel, S.; Smith, A.; Tetzlaff, D.

    2017-12-01

    The dynamics of water storage in a catchment provides a fundamental insight into the interlinkages between input and output fluxes, and how these are affected by environmental change. Such dynamics also mediate, and help us understand, the fundamental difference of the rapid celerity of the rainfall-runoff (minutes to hours) response of catchments and the much slower velocity of water particles (months to decades) as they are transported through catchment systems. In this contribution we report an intensive, long-term (>10year), multi-scale isotope study in the Scottish Highlands that has sought to better understand these issues. We have integrated empirical data collection with diverse modelling approaches to quantify the dynamics and residence times of storage in different compartments of the hydrological system (vegetation canopies, soils, ground waters etc.) and their relationship between the magnitude and travel time distributions of output fluxes (stream flow, transpiration and evaporation). Use of conceptual, physically-based and probabilistic modelling approaches give broadly consistent perspectives on the storage-discharge relationships and the preferential selection of younger waters in runoff, evaporation and transpiration; while older waters predominate in groundwater. The work also highlighted the importance role vegetation plays in regulating fluxes in evaporation and transpiration and how this contributes to the differential ageing of water in mobile and bulk waters in the soil compartment. A separate case study shows how land use change can affect storage distributions in a catchment and radically change travel time distributions in output fluxes.

  11. Equivalent electricity storage capacity of domestic thermostatically controlled loads

    International Nuclear Information System (INIS)

    Sossan, Fabrizio

    2017-01-01

    A method to quantify the equivalent storage capacity inherent the operation of thermostatically controlled loads (TCLs) is developed. Equivalent storage capacity is defined as the amount of power and electricity consumption which can be deferred or anticipated in time with respect to the baseline consumption (i.e. when no demand side event occurs) without violating temperature limits. The analysis is carried out for 4 common domestic TCLs: an electric space heating system, freezer, fridge, and electric water heater. They are simulated by applying grey-box thermal models identified from measurements. They describe the heat transfer of the considered TCLs as a function of the electric power consumption and environment conditions. To represent typical TCLs operating conditions, Monte Carlo simulations are developed, where models inputs and parameters are sampled from relevant statistical distributions. The analysis provides a way to compare flexible demand against competitive storage technologies. It is intended as a tool for system planners to assess the TCLs potential to support electrical grid operation. In the paper, a comparison of the storage capacity per unit of capital investment cost is performed considering the selected TCLs and two grid-connected battery storage systems (a 720 kVA/500 kWh lithium-ion unit and 15 kVA/120 kWh Vanadium flow redox) is performed. - Highlights: • The equivalent storage capacity of domestic TCLs is quantified • A comparison with battery-based storage technologies is performed • We derive metrics for system planners to plan storage in power system networks • Rule-of-thumb cost indicators for flexible demand and battery-based storage

  12. Testing odorants recovery from a novel metallized fluorinated ethylene propylene gas sampling bag.

    Science.gov (United States)

    Zhu, Wenda; Koziel, Jacek A; Cai, Lingshuang; Wright, Donald; Kuhrt, Fred

    2015-12-01

    Industry-standard Tedlar bags for odor sample collection from confined animal feeding operations (CAFOs) have been challenged by the evidence of volatile organic compound (VOC) losses and background interferences. Novel impermeable aluminum foil with a thin layer of fluorinated ethylene propylene (FEP) film on the surface that is in contact with a gas sample was developed to address this challenge. In this research, Tedlar and metallized FEP bags were compared for (a) recoveries of four characteristic CAFO odorous VOCs (ethyl mercaptan, butyric acid, isovaleric acid and p-cresol) after 30 min and 24 hr sample storage time and for (b) chemical background interferences. All air sampling and analyses were performed with solid-phase microextraction (SPME) followed by gas chromatography-mass spectroscopy (GC-MS). Mean target gas sample recoveries from metallized FEP bags were 25.9% and 28.0% higher than those in Tedlar bags, for 30 min and 24 hr, respectively. Metallized FEP bags demonstrated the highest p-cresol recoveries after 30-min and 24-hr storage, 96.1±44.5% and 44.8±10.2%, respectively, among different types of sampling bags reported in previous studies. However, a higher variability was observed for p-cresol recovery with metallized FEP bags. A 0% recovery of ethyl mercaptan was observed with Tedlar bags after 24-hr storage, whereas an 85.7±7.4% recovery was achieved with metallized FEP bags. Recoveries of butyric and isovaleric acids were similar for both bag types. Two major impurities in Tedlar bags' background were identified as N,N-dimethylacetamide and phenol, while backgrounds of metallized FEP bags were significantly cleaner. Reusability of metallized FEP bags was tested. Caution is advised when using polymeric materials for storage of livestock-relevant odorous volatile organic compounds. The odorants loss with storage time confirmed that long-term storage in whole-air form is ill advised. A focused short-term odor sample containment should be

  13. Battery Energy Storage Sizing When Time of Use Pricing Is Applied

    Science.gov (United States)

    Khormali, Shahab

    2014-01-01

    Battery energy storage systems (BESSs) are considered a key device to be introduced to actuate the smart grid paradigm. However, the most critical aspect related to the use of such device is its economic feasibility as it is a still developing technology characterized by high costs and limited life duration. Particularly, the sizing of BESSs must be performed in an optimized way in order to maximize the benefits related to their use. This paper presents a simple and quick closed form procedure for the sizing of BESSs in residential and industrial applications when time-of-use tariff schemes are applied. A sensitivity analysis is also performed to consider different perspectives in terms of life span and future costs. PMID:25295309

  14. Battery Energy Storage Sizing When Time of Use Pricing Is Applied

    Directory of Open Access Journals (Sweden)

    Guido Carpinelli

    2014-01-01

    Full Text Available Battery energy storage systems (BESSs are considered a key device to be introduced to actuate the smart grid paradigm. However, the most critical aspect related to the use of such device is its economic feasibility as it is a still developing technology characterized by high costs and limited life duration. Particularly, the sizing of BESSs must be performed in an optimized way in order to maximize the benefits related to their use. This paper presents a simple and quick closed form procedure for the sizing of BESSs in residential and industrial applications when time-of-use tariff schemes are applied. A sensitivity analysis is also performed to consider different perspectives in terms of life span and future costs.

  15. Assessing the precision of a time-sampling-based study among GPs: balancing sample size and measurement frequency.

    Science.gov (United States)

    van Hassel, Daniël; van der Velden, Lud; de Bakker, Dinny; van der Hoek, Lucas; Batenburg, Ronald

    2017-12-04

    Our research is based on a technique for time sampling, an innovative method for measuring the working hours of Dutch general practitioners (GPs), which was deployed in an earlier study. In this study, 1051 GPs were questioned about their activities in real time by sending them one SMS text message every 3 h during 1 week. The required sample size for this study is important for health workforce planners to know if they want to apply this method to target groups who are hard to reach or if fewer resources are available. In this time-sampling method, however, standard power analyses is not sufficient for calculating the required sample size as this accounts only for sample fluctuation and not for the fluctuation of measurements taken from every participant. We investigated the impact of the number of participants and frequency of measurements per participant upon the confidence intervals (CIs) for the hours worked per week. Statistical analyses of the time-use data we obtained from GPs were performed. Ninety-five percent CIs were calculated, using equations and simulation techniques, for various different numbers of GPs included in the dataset and for various frequencies of measurements per participant. Our results showed that the one-tailed CI, including sample and measurement fluctuation, decreased from 21 until 3 h between one and 50 GPs. As a result of the formulas to calculate CIs, the increase of the precision continued and was lower with the same additional number of GPs. Likewise, the analyses showed how the number of participants required decreased if more measurements per participant were taken. For example, one measurement per 3-h time slot during the week requires 300 GPs to achieve a CI of 1 h, while one measurement per hour requires 100 GPs to obtain the same result. The sample size needed for time-use research based on a time-sampling technique depends on the design and aim of the study. In this paper, we showed how the precision of the

  16. Non-Cartesian MRI scan time reduction through sparse sampling

    NARCIS (Netherlands)

    Wajer, F.T.A.W.

    2001-01-01

    Non-Cartesian MRI Scan-Time Reduction through Sparse Sampling Magnetic resonance imaging (MRI) signals are measured in the Fourier domain, also called k-space. Samples of the MRI signal can not be taken at will, but lie along k-space trajectories determined by the magnetic field gradients. MRI

  17. A comparative study of two approaches to analyse groundwater recharge, travel times and nitrate storage distribution at a regional scale

    Science.gov (United States)

    Turkeltaub, T.; Ascott, M.; Gooddy, D.; Jia, X.; Shao, M.; Binley, A. M.

    2017-12-01

    Understanding deep percolation, travel time processes and nitrate storage in the unsaturated zone at a regional scale is crucial for sustainable management of many groundwater systems. Recently, global hydrological models have been developed to quantify the water balance at such scales and beyond. However, the coarse spatial resolution of the global hydrological models can be a limiting factor when analysing regional processes. This study compares simulations of water flow and nitrate storage based on regional and global scale approaches. The first approach was applied over the Loess Plateau of China (LPC) to investigate the water fluxes and nitrate storage and travel time to the LPC groundwater system. Using raster maps of climate variables, land use data and soil parameters enabled us to determine fluxes by employing Richards' equation and the advection - dispersion equation. These calculations were conducted for each cell on the raster map in a multiple 1-D column approach. In the second approach, vadose zone travel times and nitrate storage were estimated by coupling groundwater recharge (PCR-GLOBWB) and nitrate leaching (IMAGE) models with estimates of water table depth and unsaturated zone porosity. The simulation results of the two methods indicate similar spatial groundwater recharge, nitrate storage and travel time distribution. Intensive recharge rates are located mainly at the south central and south west parts of the aquifer's outcrops. Particularly low recharge rates were simulated in the top central area of the outcrops. However, there are significant discrepancies between the simulated absolute recharge values, which might be related to the coarse scale that is used in the PCR-GLOBWB model, leading to smoothing of the recharge estimations. Both models indicated large nitrate inventories in the south central and south west parts of the aquifer's outcrops and the shortest travel times in the vadose zone are in the south central and east parts of the

  18. Changes of microbial spoilage, lipid-protein oxidation and physicochemical properties during post mortem refrigerated storage of goat meat.

    Science.gov (United States)

    Sabow, Azad Behnan; Sazili, Awis Qurni; Aghwan, Zeiad Amjad; Zulkifli, Idrus; Goh, Yong Meng; Ab Kadir, Mohd Zainal Abidin; Nakyinsige, Khadijah; Kaka, Ubedullah; Adeyemi, Kazeem Dauda

    2016-06-01

    Examined was the effect of post mortem refrigerated storage on microbial spoilage, lipid-protein oxidation and physicochemical traits of goat meat. Seven Boer bucks were slaughtered, eviscerated and aged for 24 h. The Longissimus lumborum (LL) and Semitendinosus (ST) muscles were excised and subjected to 13 days post mortem refrigerated storage. The pH, lipid and protein oxidation, tenderness, color and drip loss were determined in LL while microbiological analysis was performed on ST. Bacterial counts generally increased with increasing aging time and the limit for fresh meat was reached at day 14 post mortem. Significant differences were observed in malondialdehyde (MDA) content at day 7 of storage. The thiol concentration significantly reduced as aging time increased. The band intensities of myosin heavy chain (MHC) and troponin-T significantly decreased as storage progressed, while actin remained relatively stable. After 14 days of aging, tenderness showed significant improvement while muscle pH and drip loss reduced with increase in storage time. Samples aged for 14 days had higher lightness (P goat meat. © 2016 Japanese Society of Animal Science.

  19. Pricing and Application of Electric Storage

    Science.gov (United States)

    Zhao, Jialin

    Electric storage provides a vehicle to store power for future use. It contributes to the grids in multiple aspects. For instance, electric storage is a more effective approach to provide electricity ancillary services than conventional methods. Additionally, electric storage, especially fast-responding units, allows owners to implement high-frequency power transactions in settings such as the 5-min real-time trading market. Such high-frequency power trades were limited in the past. However, as technology advances, the power markets have evolved. For instance, the California Independent System Operator now supports the 5-min real-time trading and the hourly day-ahead ancillary services bidding. Existing valuation models of electric storage were not designed to accommodate these recent market developments. To fill this gap, I focus on the fast-responding grid-level electric storage that provides both the real-time trading and the day-ahead ancillary services bidding. To evaluate such an asset, I propose a Monte Carlo Simulation-based valuation model. The foundation of my model is simulations of power prices. This study develops a new simulation model of electric prices. It is worth noting that, unlike existing models, my proposed simulation model captures the dependency of the real-time markets on the day-ahead markets. Upon such simulations, this study investigates the pricing and the application of electric storage at a 5-min granularity. Essentially, my model is a Dynamic Programming system with both endogenous variables (i.e., the State-of-Charge of electric storage) and exogenous variables (i.e., power prices). My first numerical example is the valuation of a fictitious 4MWh battery. Similarly, my second example evaluates the application of two units of 2MWh batteries. By comparing these two experiments, I investigate the issues related to battery configurations, such as the impacts of splitting storage capability on the valuation of electric storage.

  20. Digital device for synchronous storage

    International Nuclear Information System (INIS)

    Kobzar', Yu.M.; Kovtun, V.G.; Pashechko, N.I.

    1991-01-01

    Synchronous storage digital device for IR electron-photon emission spectrometer operating with analogue-to-digital converter F4223 or monocrystal converter K572PV1 is described. The device accomplished deduction of noise-background in each storage cycle. Summation and deduction operational time equals 90 ns, device output code discharge - 20, number of storages -2 23

  1. Elimination of heparin interference during microarray processing of fresh and biobank-archived blood samples.

    Science.gov (United States)

    Hebels, Dennie G A J; van Herwijnen, Marcel H M; Brauers, Karen J J; de Kok, Theo M C M; Chalkiadaki, Georgia; Kyrtopoulos, Soterios A; Kleinjans, Jos C S

    2014-07-01

    In the context of environmental health research, biobank blood samples have recently been identified as suitable for high-throughput omics analyses enabling the identification of new biomarkers of exposure and disease. However, blood samples containing the anti-coagulant heparin could complicate transcriptomic analysis because heparin may inhibit RNA polymerase causing inefficient cRNA synthesis and fluorophore labelling. We investigated the inhibitory effect of heparin and the influence of storage conditions (0 or 3 hr bench times, storage at room temperature or -80°C) on fluorophore labelling in heparinized fresh human buffy coat and whole blood biobank samples during the mRNA work-up protocol for microarray analysis. Subsequently, we removed heparin by lithium chloride (LiCl) treatment and performed a quality control analysis of LiCl-treated biobank sample microarrays to prove their suitability for downstream data analysis. Both fresh and biobank samples experienced varying degrees of heparin-induced inhibition of fluorophore labelling, making most samples unusable for microarray analysis. RNA derived from EDTA and citrate blood was not inhibited. No effect of bench time was observed but room temperature storage gave slightly better results. Strong correlations were observed between original blood sample RNA yield and the amount of synthesized cRNA. LiCl treatment restored sample quality to normal standards in both fresh and biobank samples and the previously identified correlations disappeared. Microarrays hybridized with LiCl-treated biobank samples were of excellent quality with no identifiable influence of heparin. We conclude that, to obtain high quality results, in most cases heparin removal is essential in blood-derived RNA samples intended for microarray analysis. Copyright © 2014 Wiley Periodicals, Inc.

  2. Modular vault dry storage system for interim storage of irradiated fuel

    International Nuclear Information System (INIS)

    Cundill, B.R.; Ealing, C.J.; Agarwal, B.K.

    1988-01-01

    The Foster Wheeler Energy Application (FWEA) Modular Vault Dry Store (MVDS) is a dry storage concept for the storage of all types of irradiated reactor fuel. For applications in the US, FWEA submitted an MVDS Topical Report to the US NRC during 1986. Following NRC approval of the MVDS Topical Report concept for unconsolidated LWR fuel, US utilities have available a new, compact, economic and flexible system for the storage of irradiated fuel at the reactor site for time periods of at least 20 years (the period of the first license). The MVDS concept jointly developed by FWEA and GEC in the U.K., has other applications for large central away from reactor storage facilities such as a Monitorable Retrievable Storage (MRS) installation. This paper describes the licensed MVDS design, aspects of performance are discussed and capital costs compared with alternative concepts. Alternative configurations of MVDS are outlined

  3. Influence of storage in the texture and viscoelasticity of buns of corn variety white Cariaco

    Directory of Open Access Journals (Sweden)

    José David Torres-González

    2016-09-01

    Full Text Available The objective was to determine the influence of storage time on the variation of texture and visco-elasticity of buns of corn of the white Cariaco variety. The samples were stored refrigerated at 15 °C during 15 days. Textural parameters were determined every two days, using a texture analyzer; viscoelastic properties were set by a test of relaxation and com-pression effort, adjusting the experimental data to the generalized Maxwell model. Also, to determine the model parameters described, an iterative process was performed by non-linear regression using least squares techniques damped by the Solver add-on in Excel 2013. The storage time influenced the texture profile of buns, and the increase of hardness from the eleventh day, which was attributed to moisture loss of the product during cooling. Chewiness was higher for longer storage time. Cohesiveness, adhesiveness and elasticity reported no significant differences with respect to storage time. Statistical differences were presented at initial and final relaxation speeds expressed in the Maxwell model. The experimental data were successfully fitted to the model (R2 > 0.95 which was statistically significant (p < 0.05 and the performance of the elastic module indicated that buns from the white Cariaco variety showed a characteristic behavior of a viscoelastic material, increasing its hardness during the days of storage.

  4. Antilisterial properties of marinades during refrigerated storage and microwave oven reheating against post-cooking inoculated chicken breast meat.

    Science.gov (United States)

    Fouladkhah, Aliyar; Geornaras, Ifigenia; Nychas, George-John; Sofos, John N

    2013-02-01

    This study evaluated growth of Listeria monocytogenes inoculated on cooked chicken meat with different marinades and survival of the pathogen as affected by microwave oven reheating. During aerobic storage at 7 °C, on days 0, 1, 2, 4, and 7, samples were reheated by microwave oven (1100 W) for 45 or 90 s and analyzed microbiologically. L. monocytogenes counts on nonmarinated (control) samples increased (P 2.4 to 5.0 (90 s) log CFU/g. With similar trends across different marinates, the high levels of L. monocytogenes survivors found after microwave reheating, especially after storage for more than 2 d, indicate that length of storage and reheating time need to be considered for safe consumption of leftover cooked chicken. © 2013 Institute of Food Technologists®

  5. Inventory extension considerations for long-term storage at the nuclear materials storage facility

    International Nuclear Information System (INIS)

    Olinger, C.T.; Stanbro, W.D.; Longmire, V.; Argo, P.E.; Nielson, S.M.

    1996-01-01

    Los Alamos National Laboratory is in the process of modifying its nuclear materials storage facility to a long-term storage configuration. In support of this effort, we examined technical and administrative means to extend periods between physical inventories. Both the frequency and sample size during a physical inventory could significantly impact required sizing of the non-destructive assay (NDA) laboratory as well as material handling capabilities. Several options are being considered, including (1) treating each storage location as a separate vault, (2) minimizing the number of items returned for quantitative analysis by optimizing the use of in situ confirmatory measurements, and (3) utilizing advanced monitoring technologies. Careful consideration of these parameters should allow us to achieve and demonstrate safe and secure storage while minimizing the impact on facility operations and without having to increase the size of the NDA laboratory beyond that required for anticipated shipping and receiving activities

  6. Effect of liquid nitrogen storage on seed germination of 51 tree species

    Science.gov (United States)

    Jill R. Barbour; Bernard R. Parresol

    2003-01-01

    Two liquid nitrogen storage experiments were performed on 51 tree species. In experiment 1, seeds of 9western tree species were placed in a liquid nitrogen tank for 3 time periods: 24 hours, 4 weeks, and 222 days. A corresponding control sample accompanied each treatment. For three species,Calocedrus decurrens, Pinus jefferyi, and ...

  7. Storage and distribution/Linear programming for storage operations

    Energy Technology Data Exchange (ETDEWEB)

    Coleman, D

    1978-07-15

    The techniques of linear programing to solve storage problems as applied in a tank farm tie-in with refinery throughput operation include: (1) the time-phased model which works on storage and refinery operations input parameters, e.g., production, distribution, cracking, etc., and is capable of representing product stockpiling in slack periods to meet future peak demands, and investigating alternative strategies such as exchange deals and purchase and leasing of additional storage, and (2) the Monte Carlo simulation method, which inputs parameters, e.g., arrival of crude products at refinery, tankage size, likely demand for products, etc., as probability distributions rather than single values, and is capable of showing the average utilization of facilities, potential bottlenecks, investment required to achieve an increase in utilization, and to enable the user to predict total investment, cash flow, and profit emanating from the original financing decision. The increasing use of computer techniques to solve refinery and storage problems is attributed to potential savings resulting from more effective planning, reduced computer costs, ease of access and more usable software. Diagrams.

  8. Effect of storage temperature on Streptococcus mutans viability

    Directory of Open Access Journals (Sweden)

    Ana Lídia Soares COTA

    2018-04-01

    Full Text Available Abstract Introduction Proper storage conditions and maintenance of viable biological material plays an important role in microbiological research, allowing for the opportunity to conduct future studies. Objective To evaluate the viability of Streptococcus mutans strains that were previously grown and stored under different temperatures for approximately eight years. Material and method In this study, we evaluated 393 bacterial isolates that were stored in a freezer at -80°C (G1 and 200 isolates stored in a freezer at -20°C (G2. Aliquots of each sample were plated on blood agar and mitis-salivarius bacitracin sucrose agar-solidified medium. After incubating under microaerophilic conditions in an incubator at 37°C for 72 hours, the presence, morphology and purity of bacterial growth was observed. The data were analyzed by means of descriptive statistics. Result Microbial viability was observed in almost all samples (99.7% in G1, whereas all isolates stored at -20°C were considered inviable. Conclusion The viability of S. mutans is influenced by the storage temperature of the samples, and the strains remain viable when stored under ideal temperature conditions (-80°C, even when stored for a long period of time.

  9. Evaluation of BBL™ Sensi-Discs™ and FTA® cards as sampling devices for detection of rotavirus in stool samples.

    Science.gov (United States)

    Tam, Ka Ian; Esona, Mathew D; Williams, Alice; Ndze, Valantine N; Boula, Angeline; Bowen, Michael D

    2015-09-15

    Rotavirus is the most important cause of severe childhood gastroenteritis worldwide. Rotavirus vaccines are available and rotavirus surveillance is carried out to assess vaccination impact. In surveillance studies, stool samples are stored typically at 4°C or frozen to maintain sample quality. Uninterrupted cold storage is a problem in developing countries because of power interruptions. Cold-chain transportation of samples from collection sites to testing laboratories is costly. In this study, we evaluated the use of BBL™ Sensi-Discs™ and FTA(®) cards for storage and transportation of samples for virus isolation, EIA, and RT-PCR testing. Infectious rotavirus was recovered after 30 days of storage on Sensi-Discs™ at room temperature. We were able to genotype 98-99% of samples stored on Sensi-Discs™ and FTA(®) cards at temperatures ranging from -80°C to 37°C up to 180 days. A field sampling test using samples prepared and shipped from Cameroon, showed that both matrices yielded 100% genotyping success compared with whole stool and Sensi-Discs™ demonstrated 95% concordance with whole stool in EIA testing. The utilization of BBL™ Sensi-Discs™ and FTA(®) cards for stool sample storage and shipment has the potential to have great impact on global public health by facilitating surveillance and epidemiological investigations of rotavirus strains worldwide at a reduced cost. Published by Elsevier B.V.

  10. Evaluation of BBL™ Sensi-Discs™ and FTA® cards as sampling devices for detection of rotavirus in stool samples

    Science.gov (United States)

    Tam, Ka Ian; Esona, Mathew D.; Williams, Alice; Ndze, Valentine N.; Boula, Angeline; Bowen, Michael D.

    2015-01-01

    Rotavirus is the most important cause of severe childhood gastroenteritis worldwide. Rotavirus vaccines are available and rotavirus surveillance is carried out to assess vaccination impact. In surveillance studies, stool samples are stored typically at 4°C or frozen to maintain sample quality. Uninterrupted cold storage is a problem in developing countries because of power interruptions. Cold-chain transportation of samples from collection sites to testing laboratories is costly. In this study, we evaluated the use of BBL™ Sensi-Discs™ and FTA® cards for storage and transportation of samples for virus isolation, EIA, and RT-PCR testing. Infectious rotavirus was recovered after 30 days of storage on Sensi-Discs™ at room temperature. We were able to genotype 98–99% of samples stored on Sensi-Discs™ and FTA® cards at temperatures ranging from −80°C to 37°C up to 180 days. A field sampling test using samples prepared and shipped from Cameroon, showed that both matrices yielded 100% genotyping success compared with whole stool and Sensi-Discs™ demonstrated 95% concordance with whole stool in EIA testing. The utilization of BBL™ Sensi-Discs™ and FTA® cards for stool sample storage and shipment has the potential to have great impact on global public health by facilitating surveillance and epidemiological investigations of rotavirus strains worldwide at a reduced cost. PMID:26022083

  11. Storage time of platelet concentrates and risk of a positive blood culture

    DEFF Research Database (Denmark)

    Kreuger, Aukje L; Rostgaard, Klaus; Middelburg, Rutger A

    2018-01-01

    BACKGROUND: Concern of transfusion-transmitted bacterial infections has been the major hurdle to extend shelf life of platelet (PLT) concentrates. We aimed to investigate the association between storage time and risk of positive blood cultures at different times after transfusion. STUDY DESIGN...... AND METHODS: We performed a nationwide cohort study among PLT transfusion recipients in Denmark between 2010 and 2012, as recorded in the Scandinavian Donations and Transfusions (SCANDAT2) database. Linking with a nationwide database on blood cultures (MiBa), we compared the incidence of a positive blood......) of a positive blood culture the day after transfusion of at least one old PLT concentrate was 0.77 (95% confidence interval [CI], 0.54-1.09) compared to transfusion of fresh PLT concentrates. The incidence rate of a positive blood culture was lower the day after receiving one old compared to one fresh PLT...

  12. Effect of packaging during storage time on retail display shelf life of longissimus muscle from two different beef production systems.

    Science.gov (United States)

    Luzardo, S; Woerner, D R; Geornaras, I; Engle, T E; Delmore, R J; Hess, A M; Belk, K E

    2016-06-01

    Two studies were conducted to evaluate the influence of packaging and production system (PS) on retail display life color (L*, a*, and b*), fatty acid profile (% of total fatty acids), lipid oxidation (thiobarbituric acid reactive substances; mg malondialdehyde/kg of muscle), vitamin E content (µg/g of muscle), and odor (trained panelists) during storage of LM. Four (or 3) different packaging treatments were applied to LM from steers fattened on grazing systems (Uruguayan) or on high-concentrate diets (U.S.). From fabrication to application of treatments, Uruguayan LM were vacuum packaged for air shipment and U.S. LM were also vacuum packaged and kept in a cooler until Uruguayan samples arrived. Treatments were applied 7 d after slaughter. In Exp. 1, treatments were vacuum packaging (VP), low-oxygen (O) modified atmosphere packaging (MAP) with nitrogen (N2) and carbon dioxide (MAP/CO), low-O MAP with N2 plus CO and carbon monoxide (MAP/CO), and VP plus an application of peroxyacetic acid (VP/PAA). In Exp. 2 block 1, treatments were VP, MAP/CO, and VP with ethyl-arginate HCl incorporated into the film as an antimicrobial agent (VP/AM). In Exp. 2 block 2, treatments were VP, MAP/CO, MAP/CO, and VP/AM. After 35 d storage, steaks were evaluated during simulated retail display for up to 6 d. In Exp. 1, Uruguayan steaks under MAP/CO had greater ( packaging treatments on d 6 of display in Exp. 1. Packaging × PS × time interaction was significant ( 0.05) were detected among both VP and MAP/CO in U.S. steaks at this time. No significant ( > 0.05) packaging × PS × time interaction was observed in Exp. 2. Only PS (both experiments) and time (Exp. 1) affected ( Packaging × PS, PS × time, and packaging × PS × time interactions were not significant ( > 0.05) for any of the fatty acids. Beef from Uruguayan had lower ( < 0.05) SFA and MUFA and greater ( < 0.05) PUFA and n-6 and n-3 fatty acid percentages than U.S. beef. Complexity of fresh meat postmortem chemistry

  13. In-Sample Confidence Bands and Out-of-Sample Forecast Bands for Time-Varying Parameters in Observation Driven Models

    NARCIS (Netherlands)

    Blasques, F.; Koopman, S.J.; Lasak, K.A.; Lucas, A.

    2016-01-01

    We study the performances of alternative methods for calculating in-sample confidence and out-of-sample forecast bands for time-varying parameters. The in-sample bands reflect parameter uncertainty, while the out-of-sample bands reflect not only parameter uncertainty, but also innovation

  14. Comprehensive metabolomic study of platelets reveals the expression of discrete metabolic phenotypes during storage

    DEFF Research Database (Denmark)

    Paglia, Giuseppe; Sigurjónsson, Ólafur E; Rolfsson, Óttar

    2014-01-01

    performed on both the extracellular and the intracellular environments. During storage we measured 174 different variables in 6 PLT units, collected by apheresis. Samples were collected at eight different time points resulting in a data set containing more than 8000 measurements. RESULTS: Stored PLTs did...

  15. Exploratory tests of washing radioactive sludge samples from the Melton Valley and evaporator facility storage tanks at ORNL

    International Nuclear Information System (INIS)

    Sears, M.B.; Botts, J.L.; Keller, J.M.

    1991-09-01

    Exploratory tests were initiated to wash radioactive sludge samples from the waste storage tanks at the Oak Ridge National Laboratory (ORNL). The purpose was to provide preliminary information about (1) the anions in the sludge phase that are soluble in water or dilute acid (e.g., the anions in the interstitial liquid) and (2) the solubilities of sludge constituents in water under process conditions. The experiments were terminated before completion due to changing priorities by the Department of Energy (DOE). This memorandum was prepared primarily for documentation purposes and presents the incomplete data. 3 refs., 13 tabs

  16. A cryogenic electrostatic trap for long-time storage of keV ion beams.

    Science.gov (United States)

    Lange, M; Froese, M; Menk, S; Varju, J; Bastert, R; Blaum, K; López-Urrutia, J R Crespo; Fellenberger, F; Grieser, M; von Hahn, R; Heber, O; Kühnel, K-U; Laux, F; Orlov, D A; Rappaport, M L; Repnow, R; Schröter, C D; Schwalm, D; Shornikov, A; Sieber, T; Toker, Y; Ullrich, J; Wolf, A; Zajfman, D

    2010-05-01

    We report on the realization and operation of a fast ion beam trap of the linear electrostatic type employing liquid helium cooling to reach extremely low blackbody radiation temperature and residual gas density and, hence, long storage times of more than 5 min which are unprecedented for keV ion beams. Inside a beam pipe that can be cooled to temperatures <15 K, with 1.8 K reached in some locations, an ion beam pulse can be stored at kinetic energies of 2-20 keV between two electrostatic mirrors. Along with an overview of the cryogenic trap design, we present a measurement of the residual gas density inside the trap resulting in only 2 x 10(3) cm(-3), which for a room temperature environment corresponds to a pressure in the 10(-14) mbar range. The device, called the cryogenic trap for fast ion beams, is now being used to investigate molecules and clusters at low temperatures, but has also served as a design prototype for the cryogenic heavy-ion storage ring currently under construction at the Max-Planck Institute for Nuclear Physics.

  17. Sampling study in milk storage tanks by INAA

    International Nuclear Information System (INIS)

    Santos, L.G.C.; Nadai Fernandes de, E.A.; Bacchi, M.A.; Tagliaferro, F.S.

    2008-01-01

    This study investigated the representativeness of samples for assessing chemical elements in milk bulk tanks. Milk samples were collected from a closed tank in a dairy plant and from an open top tank in a dairy farm. Samples were analyzed for chemical elements by instrumental neutron activation analysis (INAA). For both experiments, Br, Ca, Cs, K, Na, Rb and Zn did not present significant differences between samples thereby indicating the appropriateness of the sampling procedure adopted to evaluate the analytes of interest. (author)

  18. Gas Exchanges and Dehydration in Different Intensities of Conditioning in Tifton 85 Bermudagrass: Nutritional Value during Hay Storage

    Directory of Open Access Journals (Sweden)

    M. Pasqualotto

    2015-06-01

    Full Text Available The present study aimed at evaluating the intensity of Tifton 85 conditioning using a mower conditioner with free-swinging flail fingers and storage times on dehydration curve, fungi presence, nutritional value and in vitro digestibility of Tifton 85 bermudagrass hay dry matter (DM. The dehydration curve was determined in the whole plant for ten times until the baling. The zero time corresponded to the plant before cutting, which occurred at 11:00 and the other collections were carried out at 8:00, 10:00, 14:00, and 16:00. The experimental design was randomised blocks with two intensities of conditioning (high and low and ten sampling times, with five replications. The high and low intensities related to adjusting the deflector plate of the free iron fingers (8 and 18 cm. In order to determine gas exchanges during Tifton 85 bermudagrass dehydration, there were evaluations of mature leaves, which were placed in the upper middle third of each branch before the cutting, at every hour for 4 hours. A portable gas analyser was used by an infrared IRGA (6400xt. The analysed variables were photosynthesis (A, stomatal conductance (gs, internal CO2 concentration (Ci, transpiration (T, water use efficiency (WUE, and intrinsic water use efficiency (WUEi. In the second part of this study, the nutritional value of Tifton 85 hay was evaluated, so randomised blocks were designed in a split plot through time, with two treatments placed in the following plots: high and low intensity of cutting and five different time points as subplots: cutting (additional treatment, baling and after 30, 60, and 90 days of storage. Subsequently, fungi that were in green plants as well as hay were determined and samples were collected from the grass at the cutting period, during baling, and after 30, 60, and 90 days of storage. It was observed that Tifton 85 bermudagrass dehydration occurred within 49 hours, so this was considered the best time for drying hay. Gas exchanges were

  19. Beam position monitor system for storage rings

    International Nuclear Information System (INIS)

    Nakamura, M.; Hinkson, J.A.

    1985-05-01

    Beam position monitors (BPM) for synchrotron light storage rings usually consist of beam pickup electrodes, coaxial relays and a narrowband receiver. While accurate, these systems are slow and of limited use in the commissioning of an accelerator. A beam position monitor is described which is intended to be a principal diagnostic during debug and routine running of a storage ring. It is capable of measuring the position of a single bunch on the first or nth orbit to an accuracy of a few percent. Stored beam position is more accurately measured with averaging techniques. Beam position changes can be studied in a bandwidth from DC to a few MHz. The beam monitor electronics consist of a separate amplification, detection, and sampling channel for each beam pickup electrode. Fast switches in each channel permit selection of the nth turn for measurement (single bunch mode). A calibration pulse is injected into each channel after beam measurement to permit gain offsets to be measured and removed from the final data. While initially more costly than the usual beam position monitor system, this sytem will pay for itself in reduced storage ring debug and trouble shooting time. 5 refs., 5 figs

  20. Ethical issues in the export, storage and reuse of human biological samples in biomedical research: perspectives of key stakeholders in Ghana and Kenya.

    Science.gov (United States)

    Tindana, Paulina; Molyneux, Catherine S; Bull, Susan; Parker, Michael

    2014-10-18

    For many decades, access to human biological samples, such as cells, tissues, organs, blood, and sub-cellular materials such as DNA, for use in biomedical research, has been central in understanding the nature and transmission of diseases across the globe. However, the limitations of current ethical and regulatory frameworks in sub-Saharan Africa to govern the collection, export, storage and reuse of these samples have resulted in inconsistencies in practice and a number of ethical concerns for sample donors, researchers and research ethics committees. This paper examines stakeholders' perspectives of and responses to the ethical issues arising from these research practices. We employed a qualitative strategy of inquiry for this research including in-depth interviews and focus group discussions with key research stakeholders in Kenya (Nairobi and Kilifi), and Ghana (Accra and Navrongo). The stakeholders interviewed emphasised the compelling scientific importance of sample export, storage and reuse, and acknowledged the existence of some structures governing these research practices, but they also highlighted the pressing need for a number of practical ethical concerns to be addressed in order to ensure high standards of practice and to maintain public confidence in international research collaborations. These concerns relate to obtaining culturally appropriate consent for sample export and reuse, understanding cultural sensitivities around the use of blood samples, facilitating a degree of local control of samples and sustainable scientific capacity building. Drawing on these findings and existing literature, we argue that the ethical issues arising in practice need to be understood in the context of the interactions between host research institutions and local communities and between collaborating institutions. We propose a set of 'key points-to-consider' for research institutions, ethics committees and funding agencies to address these issues.

  1. Liquid waste sampling device

    International Nuclear Information System (INIS)

    Kosuge, Tadashi

    1998-01-01

    A liquid pumping pressure regulator is disposed on the midway of a pressure control tube which connects the upper portion of a sampling pot and the upper portion of a liquid waste storage vessel. With such a constitution, when the pressure in the sampling pot is made negative, and liquid wastes are sucked to the liquid pumping tube passing through the sampling pot, the difference between the pressure on the entrance of the liquid pumping pressure regulator of the pressure regulating tube and the pressure at the bottom of the liquid waste storage vessel is made constant. An opening degree controlling meter is disposed to control the degree of opening of a pressure regulating valve for sending actuation pressurized air to the liquid pumping pressure regulator. Accordingly, even if the liquid level of liquid wastes in the liquid waste storage vessel is changed, the height for the suction of the liquid wastes in the liquid pumping tube can be kept constant. With such procedures, sampling can be conducted correctly, and the discharge of the liquid wastes to the outside can be prevented. (T.M.)

  2. Effect of different packaging methods and storage temperature on microbiological and physicochemical quality characteristics of meatball.

    Science.gov (United States)

    Yilmaz, I; Demirci, M

    2010-06-01

    The objective of this research was to determine physicochemical changes and microbiological quality of the different packaged meatball samples. Meatball samples in polystyrene tray were closed with polyethylene film (PS packs), vacuumed and modified atmosphere packaged, (MAP) (65% N(2), 35% CO(2)), and held under refrigerated display (4 °C) for 8, 16 and 16 days for PS packs, vacuum and MAP, respectively. Microbial load, free fatty acids and thiobarbituric acid values of the samples tended to increase with storage time. Bacteria counts of the raw meatball samples increased 2 log cycles at the end of storage compared with initial values. Meatball samples can be stored without any microbiological problem for 7 days at 4 °C. Results from this study suggested that shelf-life assigned to modified-MAP and vacuum-packed meatballs may be appropriate. Meatball samples underwent physical deformation when they were packed before vacuum process. With these negative factors considered, MAP is superior to other two packs methods.

  3. Utilizing cloud storage architecture for long-pulse fusion experiment data storage

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Ming; Liu, Qiang [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Wuhan, Hubei (China); School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, Hubei (China); Zheng, Wei, E-mail: zhenghaku@gmail.com [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Wuhan, Hubei (China); School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, Hubei (China); Wan, Kuanhong; Hu, Feiran; Yu, Kexun [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Wuhan, Hubei (China); School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, Hubei (China)

    2016-11-15

    Scientific data storage plays a significant role in research facility. The explosion of data in recent years was always going to make data access, acquiring and management more difficult especially in fusion research field. For future long-pulse experiment like ITER, the extremely large data will be generated continuously for a long time, putting much pressure on both the write performance and the scalability. And traditional database has some defects such as inconvenience of management, hard to scale architecture. Hence a new data storage system is very essential. J-TEXTDB is a data storage and management system based on an application cluster and a storage cluster. J-TEXTDB is designed for big data storage and access, aiming at improving read–write speed, optimizing data system structure. The application cluster of J-TEXTDB is used to provide data manage functions and handles data read and write operations from the users. The storage cluster is used to provide the storage services. Both clusters are composed with general servers. By simply adding server to the cluster can improve the read–write performance, the storage space and redundancy, making whole data system highly scalable and available. In this paper, we propose a data system architecture and data model to manage data more efficient. Benchmarks of J-TEXTDB performance including read and write operations are given.

  4. Utilizing cloud storage architecture for long-pulse fusion experiment data storage

    International Nuclear Information System (INIS)

    Zhang, Ming; Liu, Qiang; Zheng, Wei; Wan, Kuanhong; Hu, Feiran; Yu, Kexun

    2016-01-01

    Scientific data storage plays a significant role in research facility. The explosion of data in recent years was always going to make data access, acquiring and management more difficult especially in fusion research field. For future long-pulse experiment like ITER, the extremely large data will be generated continuously for a long time, putting much pressure on both the write performance and the scalability. And traditional database has some defects such as inconvenience of management, hard to scale architecture. Hence a new data storage system is very essential. J-TEXTDB is a data storage and management system based on an application cluster and a storage cluster. J-TEXTDB is designed for big data storage and access, aiming at improving read–write speed, optimizing data system structure. The application cluster of J-TEXTDB is used to provide data manage functions and handles data read and write operations from the users. The storage cluster is used to provide the storage services. Both clusters are composed with general servers. By simply adding server to the cluster can improve the read–write performance, the storage space and redundancy, making whole data system highly scalable and available. In this paper, we propose a data system architecture and data model to manage data more efficient. Benchmarks of J-TEXTDB performance including read and write operations are given.

  5. Stability of cactus-pear powder during storage

    Directory of Open Access Journals (Sweden)

    Plúvia O. Galdino

    2016-02-01

    Full Text Available ABSTRACT The stability of cactus-pear powder, obtained by the process of spray drying for 40 days, was evaluated under controlled conditions of relative air humidity (83% and temperature (25 and 40 °C. The whole pulp was characterized with regard to its physico-chemical parameters: pH, total titratable acidity, soluble solids, water content, total solids, ashes, reducing sugars, total sugars, non-reducing sugars, luminosity, redness, yellowness and water activity. The stored samples in powder were evaluated every 10 days for water content, water activity, total titratable acidity and color (luminosity, redness and yellowness. The whole pulp was slightly acidic and perishable, due to the high water content. During storage, the packages did not prevent water absorption, thus increasing water content and, consequently, water activity. Yellowness oscillated along the storage time, but the predominance of the yellow color was not affected.

  6. Effect of low-pressure plasma treatment on the color and oxidative stability of raw pork during refrigerated storage.

    Science.gov (United States)

    Ulbin-Figlewicz, Natalia; Jarmoluk, Andrzej

    2016-06-01

    The effect of low-pressure plasma on quality attributes of meat is an important aspect, which must be considered before application in food. The aim of this study was to determine the color, fatty acid composition, lipid oxidation expressed as thiobarbituric acid reactive substances and total antioxidant capacity of raw pork samples exposed to helium low-pressure plasma treatment (20 kPa) for 0, 2, 5, and 10 min during the storage period. The thiobarbituric acid reactive substance concentrations of all plasma-treated samples during storage were in the range from 0.26 to 0.61 mg malondialdehyde/kg. Exposure time caused significant changes only in total color difference, hue angle, and chroma after 10 min of treatment. Ferric reducing ability of plasma values of meat samples decreased from 1.93 to 1.40 mmol Trolox Eq/kg after 14 days of storage. The storage period significantly affected proportion of polyunsaturated fatty acids, with an increase about 3% after 14 days of refrigeration storage while the content of saturated fatty acids was at the same level. Helium low-pressure plasma does not induce oxidative processes. Application of this decontamination technique while maintaining product quality is possible in food industry. © The Author(s) 2015.

  7. Optimal Time to Invest Energy Storage System under Uncertainty Conditions

    Directory of Open Access Journals (Sweden)

    Yongma Moon

    2014-04-01

    Full Text Available This paper proposes a model to determine the optimal investment time for energy storage systems (ESSs in a price arbitrage trade application under conditions of uncertainty over future profits. The adoption of ESSs can generate profits from price arbitrage trade, which are uncertain because the future marginal prices of electricity will change depending on supply and demand. In addition, since the investment is optional, an investor can delay adopting an ESS until it becomes profitable, and can decide the optimal time. Thus, when we evaluate this investment, we need to incorporate the investor’s option which is not captured by traditional evaluation methods. In order to incorporate these aspects, we applied real option theory to our proposed model, which provides an optimal investment threshold. Our results concerning the optimal time to invest show that if future profits that are expected to be obtained from arbitrage trade become more uncertain, an investor needs to wait longer to invest. Also, improvement in efficiency of ESSs can reduce the uncertainty of arbitrage profit and, consequently, the reduced uncertainty enables earlier ESS investment, even for the same power capacity. Besides, when a higher rate of profits is expected and ESS costs are higher, an investor needs to wait longer. Also, by comparing a widely used net present value model to our real option model, we show that the net present value method underestimates the value for ESS investment and misleads the investor to make an investment earlier.

  8. Activation of hydrogen storage materials in the Li-Mg-N-H system: Effect on storage properties

    International Nuclear Information System (INIS)

    Yang, Jun; Sudik, Andrea; Wolverton, C.

    2007-01-01

    We investigate the thermodynamics, kinetics, and capacity of the hydrogen storage reaction: Li 2 Mg(NH) 2 + 2H 2 ↔ Mg(NH 2 ) 2 + 2LiH. Starting with LiNH 2 and MgH 2 , two distinct procedures have been previously proposed for activating samples to induce the reversible storage reaction. We clarify here the impact of these two activation procedures on the resulting capacity for the Li-Mg-N-H reaction. Additionally, we measure the temperature-dependent kinetic absorption data for this hydrogen storage system. Finally, our experiments confirm the previously reported formation enthalpy (ΔH), hydrogen capacity, and pressure-composition-isotherm (PCI) data, and suggest that this system represents a kinetically (but not thermodynamically) limited system for vehicular on-board storage applications

  9. Eigenvalue sensitivity of sampled time systems operating in closed loop

    Science.gov (United States)

    Bernal, Dionisio

    2018-05-01

    The use of feedback to create closed-loop eigenstructures with high sensitivity has received some attention in the Structural Health Monitoring field. Although practical implementation is necessarily digital, and thus in sampled time, work thus far has center on the continuous time framework, both in design and in checking performance. It is shown in this paper that the performance in discrete time, at typical sampling rates, can differ notably from that anticipated in the continuous time formulation and that discrepancies can be particularly large on the real part of the eigenvalue sensitivities; a consequence being important error on the (linear estimate) of the level of damage at which closed-loop stability is lost. As one anticipates, explicit consideration of the sampling rate poses no special difficulties in the closed-loop eigenstructure design and the relevant expressions are developed in the paper, including a formula for the efficient evaluation of the derivative of the matrix exponential based on the theory of complex perturbations. The paper presents an easily reproduced numerical example showing the level of error that can result when the discrete time implementation of the controller is not considered.

  10. Weighted statistical parameters for irregularly sampled time series

    Science.gov (United States)

    Rimoldini, Lorenzo

    2014-01-01

    Unevenly spaced time series are common in astronomy because of the day-night cycle, weather conditions, dependence on the source position in the sky, allocated telescope time and corrupt measurements, for example, or inherent to the scanning law of satellites like Hipparcos and the forthcoming Gaia. Irregular sampling often causes clumps of measurements and gaps with no data which can severely disrupt the values of estimators. This paper aims at improving the accuracy of common statistical parameters when linear interpolation (in time or phase) can be considered an acceptable approximation of a deterministic signal. A pragmatic solution is formulated in terms of a simple weighting scheme, adapting to the sampling density and noise level, applicable to large data volumes at minimal computational cost. Tests on time series from the Hipparcos periodic catalogue led to significant improvements in the overall accuracy and precision of the estimators with respect to the unweighted counterparts and those weighted by inverse-squared uncertainties. Automated classification procedures employing statistical parameters weighted by the suggested scheme confirmed the benefits of the improved input attributes. The classification of eclipsing binaries, Mira, RR Lyrae, Delta Cephei and Alpha2 Canum Venaticorum stars employing exclusively weighted descriptive statistics achieved an overall accuracy of 92 per cent, about 6 per cent higher than with unweighted estimators.

  11. Volatile Discrimination of Irradiated and Fumigated White Ginseng Powders at Different Storage Times and Temperatures Using the Electronic Nose

    International Nuclear Information System (INIS)

    Kwon, J.H.; Shin, J.A.; Lee, K.T.

    2006-01-01

    The pattern of volatile emissions from white ginseng powders (WGP) that were treated with selected preservatives was investigated during 5-months of storage (at-10 and 25℃) by an electronic nose system equipped with 12 metal-oxide sensors. WGP were treated with gamma radiation at 5 kGy, commercial methyl bromide (MeBr), and phosphine fumigations. Electronic nose differentiated the volatile patterns of the WGP with each different preservative treatment. In addition, each volatile pattern was affected by both storage time (1, 2 and 5 months) and temperature (-10 and 25℃)

  12. Lactated Ringer-based storage solutions are equally well suited for the storage of fresh osteochondral allografts as cell culture medium-based storage solutions.

    Science.gov (United States)

    Harb, Afif; von Horn, Alexander; Gocalek, Kornelia; Schäck, Luisa Marilena; Clausen, Jan; Krettek, Christian; Noack, Sandra; Neunaber, Claudia

    2017-07-01

    Due to the rising interest in Europe to treat large cartilage defects with osteochondrale allografts, research aims to find a suitable solution for long-term storage of osteochondral allografts. This is further encouraged by the fact that legal restrictions currently limit the use of the ingredients from animal or human sources that are being used in other regions of the world (e.g. in the USA). Therefore, the aim of this study was A) to analyze if a Lactated Ringer (LR) based solution is as efficient as a Dulbecco modified Eagle's minimal essential medium (DMEM) in maintaining chondrocyte viability and B) at which storage temperature (4°C vs. 37°C) chondrocyte survival of the osteochondral allograft is optimally sustained. 300 cartilage grafts were collected from knees of ten one year-old Black Head German Sheep. The grafts were stored in four different storage solutions (one of them DMEM-based, the other three based on Lactated Ringer Solution), at two different temperatures (4 and 37°C) for 14 and 56days. At both points in time, chondrocyte survival as well as death rate, Glycosaminoglycan (GAG) content, and Hydroxyproline (HP) concentration were measured and compared between the grafts stored in the different solutions and at the different temperatures. Independent of the storage solutions tested, chondrocyte survival rates were higher when stored at 4°C compared to storage at 37°C both after short-term (14days) and long-term storage (56days). At no point in time did the DMEM-based solution show a superior chondrocyte survival compared to lactated Ringer based solution. GAG and HP content were comparable across all time points, temperatures and solutions. LR based solutions that contain only substances that are approved in Germany may be just as efficient for storing grafts as the USA DMEM-based solution gold standard. Moreover, in the present experiment storage of osteochondral allografts at 4°C was superior to storage at 37°C. Copyright © 2017

  13. Filter paper saturated by urine sample in metabolic disorders detection by proton magnetic resonance spectroscopy.

    Science.gov (United States)

    Blasco, Hélène; Garrigue, Marie-Ange; De Vos, Aymeric; Antar, Catherine; Labarthe, François; Maillot, François; Andres, Christian R; Nadal-Desbarats, Lydie

    2010-02-01

    NMR spectroscopy of urine samples is able to diagnose many inborn errors of metabolism (IEM). However, urinary metabolites have a poor stability, requiring special care for routine analysis (storage of urine at -20 or -80 degrees C, fast transport). The aim of our study was to investigate the reliability of dried urine filter paper for urine storage and transport and to evaluate the ability of NMR to detect several IEM using this method. Urine samples from five healthy subjects were analyzed by (1)H NMR following different storage conditions (-20 vs 4 degrees C vs dried on filter paper) and at different time points (24 h, 48 h, 96 h, and 7 days). Urine pattern of fresh urine was considered as a reference. We analyzed the conservation of some amino acids and organic acids using Bland and Altman plot with intraclass correlation coefficient determination. Then, we evaluated the use of filter paper to detect four different IEM (methylmalonic and isovaleric acidurias, ornithine transcarbamylase deficiency, and cystinuria). Analysis of urine samples from healthy subjects revealed a high stability of studied molecules (ICC > 0.8) even after 7 days of storage on filter paper. Moreover, an excellent preservation of metabolites specifically accumulated in IEM was observed when analysis of dried urine filter paper was compared to fresh urine (coefficient of variation storage of dried urine on filter paper is reliable for (1)H NMR spectroscopy analysis. Preservation of urine molecules over time using that method is convenient for routine clinical practice.

  14. A Dynamic Programming Model for Optimizing Frequency of Time-Lapse Seismic Monitoring in Geological CO2 Storage

    Science.gov (United States)

    Bhattacharjya, D.; Mukerji, T.; Mascarenhas, O.; Weyant, J.

    2005-12-01

    Designing a cost-effective and reliable monitoring program is crucial to the success of any geological CO2 storage project. Effective design entails determining both, the optimal measurement modality, as well as the frequency of monitoring the site. Time-lapse seismic provides the best spatial coverage and resolution for reservoir monitoring. Initial results from Sleipner (Norway) have demonstrated effective monitoring of CO2 plume movement. However, time-lapse seismic is an expensive monitoring technique especially over the long term life of a storage project and should be used judiciously. We present a mathematical model based on dynamic programming that can be used to estimate site-specific optimal frequency of time-lapse surveys. The dynamics of the CO2 sequestration process are simplified and modeled as a four state Markov process with transition probabilities. The states are M: injected CO2 safely migrating within the target zone; L: leakage from the target zone to the adjacent geosphere; R: safe migration after recovery from leakage state; and S: seepage from geosphere to the biosphere. The states are observed only when a monitoring survey is performed. We assume that the system may go to state S only from state L. We also assume that once observed to be in state L, remedial measures are always taken to bring it back to state R. Remediation benefits are captured by calculating the expected penalty if CO2 seeped into the biosphere. There is a trade-off between the conflicting objectives of minimum discounted costs of performing the next time-lapse survey and minimum risk of seepage and its associated costly consequences. A survey performed earlier would spot the leakage earlier. Remediation methods would have been utilized earlier, resulting in savings in costs attributed to excessive seepage. On the other hand, there are also costs for the survey and remedial measures. The problem is solved numerically using Bellman's optimality principal of dynamic

  15. Stability of heparin blood samples during transport based on defined pre-analytical quality goals

    DEFF Research Database (Denmark)

    Jensen, Esther A; Stahl, Marta; Brandslund, Ivan

    2008-01-01

    BACKGROUND: In many countries and especially in Scandinavia, blood samples drawn in primary healthcare are sent to a hospital laboratory for analysis. The samples are exposed to various conditions regarding storage time, storage temperature and transport form. As these factors can have a severe...... impact on the quality of results, we wanted to study which combination of transport conditions could fulfil our pre-defined goals for maximum allowable error. METHODS: Samples from 406 patients from nine general practitioners (GPs) in two Danish counties were sent to two hospitals for analyses, during......, centrifuged and separated at the doctor's office within 45-60 min. This sample was considered as the best estimate of a comparison value. RESULTS: The pre-set quality goals were fulfilled for all the investigated components for samples transported to hospital by courier either as whole blood or as "on gel...

  16. Metabolomic approach: postharvest storage stability of red radish (raphanus sativus l.)

    International Nuclear Information System (INIS)

    Jahangir, M.; Farid, J.B.A.

    2014-01-01

    Post harvest storage of vegetables at different temperature for consumption is commonly practiced that need standardization. Among vegetables, red radish (Raphanus sativus L.) is a well known and commonly consumed vegetable all over the world. Its bioactive or nutritional constituents include a wide range of metabolites including, glucosinolates, phenolics, amino acids, organic acids, and sugars. However, many of these metabolites are not stable and can easily be degraded or modified during storage. In order to investigate the metabolomic changes during post harvest storage, radish samples (intact roots and aerial parts) were subjected to four different storage temperatures above and below 0 degree C (20 degree C, 4 degree C, -20 degree C, and -80 degree C), for a maximum of 28 days. 1H-NMR and two-dimensional NMR spectra data resulting from the analysis of the different samples were subjected to principal component analysis (PCA) to investigate any possible metabolomic changes. A profound chemical alteration was observed in primary and secondary metabolites. Glucosinolates, phenylpropanoids, organic acids, amino acids, and sugars were found to be the discriminating metabolites for the storage effect. Initially, an increase in secondary metabolites (phenolics and glucosinolates) was observed, but levels of these compounds decreased in later stages, probably due to the breakdown of these products. Whereas late storage samples contained high amounts of amino acids (alanine, valine, threonine, (gama-amino-butyric acid / GABA)) and some glucosinolates (glucobrassicin, neoglucobrassicin). This phenomenon was pronounced at room temperature as compared to other storage temperatures. Interestingly even at lower and freezing temperatures metabolomic changes in these biological samples were observed. The least metabolomic changes were observed at samples stored at -80 degree C. While studying temperature dependent metabolomic changes, high levels of glucose, adenine, alanine

  17. Effects of sample drying and storage, and choice of extraction solvent and analysis method on the yield of birch leaf hydrolyzable tannins.

    Science.gov (United States)

    Salminen, Juha-Pekka

    2003-06-01

    In this study, I investigated the effects of different methods of sample drying and storage, and the choice of extraction solvent and analysis method on the concentrations of 14 individual hydrolyzable tannins (HTs), and insoluble ellagitannins in birch (Betula pubescens) leaves. Freeze- and vacuum-drying of birch leaves were found to provide more reliable results than air- or oven-drying. Storage of leaves at -20 degrees C for 3 months before freeze-drying did not cause major changes in tannin content, although levels of 1,2,3,4,6-penta-O-galloylglucose and isostrictinin were altered. Storage of dried leaf material at -20 degrees C is preferred because 1 year storage of freeze-dried leaves at 4 degrees C and at room temperature decreased the concentration of the pedunculagin derivative, one of the main ellagitannins of birch. Furthermore, storage at room temperature increased the levels of isostrictinin and 2,3-(S)-HHDP-glucose, indicating possible HT catabolism. Of the extraction solvents tested, aqueous acetone was superior to pure acetone, or aqueous or pure methanol. The addition of 0.1% ascorbic acid into 70% acetone significantly increased the yield of ellagitannins. presumably by preventing their oxidation. By comparing the conventional rhodanine assay and the HPLC-ESI-MS assay for quantification of leaf galloylglucoses, the former tends to underestimate total concentrations of galloylglucoses in birch leaf extract. On the basis of the outcomes of all the method and solvent comparisons, their suitability for qualitative and quantitative analysis of plant HTs is discussed, emphasizing that each plant species, with its presumably unique HT composition, is likely to have a unique combination of ideal conditions for tissue preservation and extraction.

  18. Activity of water content and storage temperature on the seed-borne mycoflora of lens culinaris

    International Nuclear Information System (INIS)

    Rahim, S.; Dawar, S.

    2014-01-01

    Storage of seeds with high water content and temperatures favors the growth of mould fungi which in turn affect the germination of seeds while low temperature with low water content prevent the growth of storage fungi and help in maintaining seed viability for longer duration of time. Seed sample from Sukkur district was stored at 4 degree C and room temperature (25-30 degree C) with water content of 8, 13 and 17% for about 80 days. The fungi were isolated at 0, 20, 40, 60 and 80 days intervals. Highest infection percentage of fungi was observed at 13 and 17% water contents at room temperature after 20 days of storage. High infection percentage of storage fungi affected the germination of seeds. Aspergillus spp were the most dominant fungi. (author)

  19. Flywheel energy storage; Schwungmassenspeicher

    Energy Technology Data Exchange (ETDEWEB)

    Bornemann, H.J. [Forschungszentrum Karlsruhe GmbH Technik und Umwelt (Germany)

    1996-12-31

    Energy storages may be chemical systems such as batteries, thermal systems such as hot-water tanks, electromagnetic systems such as capacitors and coils, or mechanical systems such as pumped storage power systems or flywheel energy storages. In flywheel energy storages the energy is stored in the centrifugal mass in the form of kinetic energy. This energy can be converted to electricity via a motor/generator unit and made available to the consumer. The introduction of magnetic bearings has greatly enhanced the potential of flywheel energy storages. As there is no contact between the moving parts of magnetic bearings, this technology provides a means of circumventing the engineering and operational problems involved in the we of conventional bearings (ball, roller, plain, and gas bearings). The advantages of modern flywheel energy storages over conventional accumulators are an at least thousandfold longer service life, low losses during long-time storage, greater power output in the case of short-time storage, and commendable environmental benignity. (orig./HW) [Deutsch] Als Enegiespeicher kommen chemische Systeme, z.B. Batterien, thermische Systeme, z.B. Warmwassertanks, elektromagnetische Systeme, z.B. Kondensatoren und Spulen, sowie mechanische Systeme, z.B. Pumpspeicherwerke und Schwungmassenspeicher in Frage. In einem Schwungmassenspeicher wird Energie in Form von kinetischer Energie in der Schwungmasse gespeichert. Ueber eine Moter/Generator Einheit wird diese Energie in elektrischen Strom umgewandelt und dem Verbraucher zugefuehrt. Mit der Einfuehrung von magnetischen Lagern konnte die Leistungsfaehigkeit von Schwungmassenspeichern erheblich gesteigert werden. Da in einem Magnetlager keine Beruehrung zwischen sich bewegenden Teilen besteht, wird ein Grossteil der mit dem Einsatz konventioneller Lager (Kugel- und Rollenlager, Gleitlager und Gaslager) verbundenen ingenieurtechnischen und betriebstechnischen Probleme vermieden. Die Vorteile von modernen

  20. Sample handling factors affecting the enumeration of lactobacilli and cellulolytic bacteria in equine feces

    Science.gov (United States)

    The objectives were to compare media types and evaluate the effects of fecal storage time and temperature on the enumeration of cellulolytic bacteria and lactobacilli from horses. Fecal samples were collected from horses (n = 3) and transported to the lab (CO2, 37 ºC, 0.5 h). The samples were assign...

  1. Terrestrial carbon storage dynamics: Chasing a moving target

    Science.gov (United States)

    Luo, Y.; Shi, Z.; Jiang, L.; Xia, J.; Wang, Y.; Kc, M.; Liang, J.; Lu, X.; Niu, S.; Ahlström, A.; Hararuk, O.; Hastings, A.; Hoffman, F. M.; Medlyn, B. E.; Rasmussen, M.; Smith, M. J.; Todd-Brown, K. E.; Wang, Y.

    2015-12-01

    Terrestrial ecosystems have been estimated to absorb roughly 30% of anthropogenic CO2 emissions. Past studies have identified myriad drivers of terrestrial carbon storage changes, such as fire, climate change, and land use changes. Those drivers influence the carbon storage change via diverse mechanisms, which have not been unified into a general theory so as to identify what control the direction and rate of terrestrial carbon storage dynamics. Here we propose a theoretical framework to quantitatively determine the response of terrestrial carbon storage to different exogenous drivers. With a combination of conceptual reasoning, mathematical analysis, and numeric experiments, we demonstrated that the maximal capacity of an ecosystem to store carbon is time-dependent and equals carbon input (i.e., net primary production, NPP) multiplying by residence time. The capacity is a moving target toward which carbon storage approaches (i.e., the direction of carbon storage change) but usually does not attain. The difference between the capacity and the carbon storage at a given time t is the unrealized carbon storage potential. The rate of the storage change is proportional to the magnitude of the unrealized potential. We also demonstrated that a parameter space of NPP, residence time, and carbon storage potential can well characterize carbon storage dynamics quantified at six sites ranging from tropical forests to tundra and simulated by two versions (carbon-only and coupled carbon-nitrogen) of the Australian Community Atmosphere-Biosphere Land Ecosystem (CABLE) Model under three climate change scenarios (CO2 rising only, climate warming only, and RCP8.5). Overall this study reveals the unified mechanism unerlying terrestrial carbon storage dynamics to guide transient traceability analysis of global land models and synthesis of empirical studies.

  2. Long term storage of dry versus frozen RNA for next generation molecular studies.

    Directory of Open Access Journals (Sweden)

    Eric Seelenfreund

    Full Text Available The standard method for the storage and preservation of RNA has been at ultra-low temperatures. However, reliance on liquid nitrogen and freezers for storage of RNA has multiple downsides. Recently new techniques have been developed for storing RNA at room temperature utilizing desiccation and are reported to be an effective alternative for preserving RNA integrity. In this study we compared frozen RNA samples stored for up to one year to those which had been desiccated using RNAstable (Biomatrica, Inc., San Diego, CA and stored at room temperature. RNA samples were placed in aliquots and stored after desiccation or frozen (at -80°C, and were analyzed for RNA Integrity Number (RIN, and by qPCR, and RNA sequencing. Our study shows that RNAstable is able to preserve desiccated RNA samples at room temperature for up to one year, and that RNA preserved by desiccation is comparable to cryopreserved RNA for downstream analyses including real-time-PCR and RNA sequencing.

  3. Effects of Storage Time on the Quality of Local Chicken Meat ...

    African Journals Online (AJOL)

    An experiment was carried out to investigate the proximate composition and effects of aging time on local chicken meat quality. For proximate analysis, 24 male and 24 female breast, thigh and drumstick samples from one half of the carcass were skinned, de-boned and frozen at -20oC. The samples were minced through a ...

  4. Compact nuclear fuel storage

    International Nuclear Information System (INIS)

    Kiselev, V.V.; Churakov, Yu.A.; Danchenko, Yu.V.; Bylkin, B.K.; Tsvetkov, S.V.

    1983-01-01

    Different constructions of racks for compact storage of spent fuel assemblies (FA) in ''coolin''g pools (CP) of NPPs with the BWR and PWR type reactors are described. Problems concerning nuclear and radiation safety and provision of necessary thermal conditions arising in such rack design are discussed. It is concluded that the problem of prolonged fuel storage at NPPs became Very actual for many countries because of retapdation of the rates of fuel reprocessing centers building. Application of compact storage racks is a promising solution of the problem of intermediate FA storage at NPPs. Such racks of stainless boron steel and with neutron absorbers in the from of boron carbide panels enable to increase the capacity of the present CP 2-2.6 times, and the period of FA storage in them up to 5-10 years

  5. The impact of storage time of transfused blood on postoperative infectious complications in rectal cancer surgery. Danish RANX05 Colorectal Cancer Study Group

    DEFF Research Database (Denmark)

    Mynster, T; Nielsen, Hans Jørgen

    2000-01-01

    BACKGROUND: We have studied the impact of storage time of transfused allogeneic blood together with other known risk factors on postoperative infectious complications after operation for rectal cancer. METHODS: Intra-abdominal abscess, anastomotic leakage, septicaemia, wound infection, and pneumo......BACKGROUND: We have studied the impact of storage time of transfused allogeneic blood together with other known risk factors on postoperative infectious complications after operation for rectal cancer. METHODS: Intra-abdominal abscess, anastomotic leakage, septicaemia, wound infection...... and storage time of saline-adenine-glucose-mannitol (SAGM) blood, administered to each patient, were recorded retrospectively. RESULTS: The overall infection rate was 24% in 78 non-transfused and 40% in 225 transfused patients (P = 0.011). The proportion of SAGM blood stored for > or = 21 days administered...... to each transfused patient was a median of 60% in patients developing postoperative infections versus 25% (P = 0.037) in patients without infections. A multivariate analysis of significant risk variables showed weight > 75 kg (odds ratio, 2.0 versus blood stored > or = 21...

  6. Evaluation of the antioxidant potential of royal jelly during storage

    Directory of Open Access Journals (Sweden)

    Renata Galhardo Borguini

    2012-09-01

    Full Text Available Royal jelly is a creamy substance produced by young nurse worker bees, which has a color that ranges from white to slightly yellow, and is secreted by the hypopharingeal and mandibular glands of the bees. The objective of this work was to assess the in vitro antioxidant potential of royal jelly while in storage. The physical-chemical parameters analyzed were moisture, ascorbic acid and total phenolic content. Alcohol extracts were made and used to evaluate the 1.1-diphenyl-2-picrylhydrazyl (DPPH radical scavenging activity. The ascorbic acid (to 0.75 from 1.31mg.100g-1wet base and total phenolic content (to 14.26 from 28.30mg GAE.100g-1 wet base of the royal jelly were low. The percentages of DPPH discoloration of the samples were above 50%, except for the samples stored for 90 days. Considering the reduced ascorbic acid and total phenolic content, and the low alcohol DPPH scavenging activity of the samples, it can be concluded that royal jelly presents relatively low antioxidant potential. The storage time did not determine the changes found.

  7. The effect of storage time of human red cells on intestinal microcirculatory oxygenation in a rat isovolemic exchange model

    NARCIS (Netherlands)

    Raat, N. J.; Verhoeven, A. J.; Mik, E. G.; Gouwerok, C. W.; Verhaar, R.; Goedhart, P. T.; de Korte, D.; Ince, C.

    2005-01-01

    Objective: To determine whether the storage time of human leukodepleted red blood cell concentrates compromises intestinal microvascular oxygen concentration oxygen (muPo(2)) during isovolemic exchange transfusion at low hematocrit. Design: Prospective, randomized, controlled study. Setting:

  8. Quantifying the benefit of wellbore leakage potential estimates for prioritizing long-term MVA well sampling at a CO2 storage site.

    Science.gov (United States)

    Azzolina, Nicholas A; Small, Mitchell J; Nakles, David V; Glazewski, Kyle A; Peck, Wesley D; Gorecki, Charles D; Bromhal, Grant S; Dilmore, Robert M

    2015-01-20

    This work uses probabilistic methods to simulate a hypothetical geologic CO2 storage site in a depleted oil and gas field, where the large number of legacy wells would make it cost-prohibitive to sample all wells for all measurements as part of the postinjection site care. Deep well leakage potential scores were assigned to the wells using a random subsample of 100 wells from a detailed study of 826 legacy wells that penetrate the basal Cambrian formation on the U.S. side of the U.S./Canadian border. Analytical solutions and Monte Carlo simulations were used to quantify the statistical power of selecting a leaking well. Power curves were developed as a function of (1) the number of leaking wells within the Area of Review; (2) the sampling design (random or judgmental, choosing first the wells with the highest deep leakage potential scores); (3) the number of wells included in the monitoring sampling plan; and (4) the relationship between a well’s leakage potential score and its relative probability of leakage. Cases where the deep well leakage potential scores are fully or partially informative of the relative leakage probability are compared to a noninformative base case in which leakage is equiprobable across all wells in the Area of Review. The results show that accurate prior knowledge about the probability of well leakage adds measurable value to the ability to detect a leaking well during the monitoring program, and that the loss in detection ability due to imperfect knowledge of the leakage probability can be quantified. This work underscores the importance of a data-driven, risk-based monitoring program that incorporates uncertainty quantification into long-term monitoring sampling plans at geologic CO2 storage sites.

  9. DNA degrades during storage in formalin-fixed and paraffin-embedded tissue blocks.

    Science.gov (United States)

    Guyard, Alice; Boyez, Alice; Pujals, Anaïs; Robe, Cyrielle; Tran Van Nhieu, Jeanne; Allory, Yves; Moroch, Julien; Georges, Odette; Fournet, Jean-Christophe; Zafrani, Elie-Serge; Leroy, Karen

    2017-10-01

    Formalin-fixed paraffin-embedded (FFPE) tissue blocks are widely used to identify clinically actionable molecular alterations or perform retrospective molecular studies. Our goal was to quantify degradation of DNA occurring during mid to long-term storage of samples in usual conditions. We selected 46 FFPE samples of surgically resected carcinomas of lung, colon, and urothelial tract, of which DNA had been previously extracted. We performed a second DNA extraction on the same blocks under identical conditions after a median period of storage of 5.5 years. Quantitation of DNA by fluorimetry showed a 53% decrease in DNA quantity after storage. Quantitative PCR (qPCR) targeting KRAS exon 2 showed delayed amplification of DNA extracted after storage in all samples but one. The qPCR/fluorimetry quantification ratio decreased from 56 to 15% after storage (p DNA analyzable by qPCR represented only 11% of the amount obtained at first extraction. Maximal length of amplifiable DNA fragments assessed with a multiplex PCR was reduced in DNA extracted from stored tissue, indicating that DNA fragmentation had increased in the paraffin blocks during storage. Next-generation sequencing was performed on 12 samples and showed a mean 3.3-fold decrease in library yield and a mean 4.5-fold increase in the number of single-nucleotide variants detected after storage. In conclusion, we observed significant degradation of DNA extracted from the same FFPE block after 4 to 6 years of storage. Better preservation strategies should be considered for storage of FFPE biopsy specimens.

  10. Carbon storage and sequestration by trees in VIT University campus

    Science.gov (United States)

    Saral, A. Mary; SteffySelcia, S.; Devi, Keerthana

    2017-11-01

    The present study addresses carbon storage and sequestration by trees grown in VIT University campus, Vellore. Approximately twenty trees were selected from Woodstockarea. The above ground biomass and below ground biomass were calculated. The above ground biomass includes non-destructive anddestructive sampling. The Non-destructive method includes the measurement of height of thetree and diameter of the tree. The height of the tree is calculated using Total Station instrument and diameter is calculated using measuring tape. In the destructive method the weight of samples (leaves) and sub-samples (fruits, flowers) of the tree were considered. To calculate the belowground biomass soil samples are taken and analyzed. The results obtained were used to predict the carbon storage. It was found that out of twenty tree samples Millingtonia hortensis which is commonly known as Cork tree possess maximum carbon storage (14.342kg/tree) and carbon sequestration (52.583kg/tree) respectively.

  11. Astaxanthin degradation and lipid oxidation of Pacific white shrimp oil: kinetics study and stability as affected by storage conditions

    Directory of Open Access Journals (Sweden)

    Sirima Takeungwongtrakul

    2016-02-01

    Full Text Available Abstract The kinetics of astaxanthin degradation and lipid oxidation in shrimp oil from hepatopancreas of Pacific white shrimp (Litopenaeus vannamei as affected by storage temperature were studied. When shrimp oil was incubated at different temperatures (4, 30, 45 and 60 °C for 16 h, the rate constants (k of astaxanthin degradation and lipid oxidation in shrimp oil increased with increasing temperatures (p < 0.05. Thus, astaxanthin degradation and lipid oxidation in shrimp oil were augmented at high temperature. When shrimp oils with different storage conditions (illumination, oxygen availability and temperature were stored for up to 40 days, astaxanthin contents in all samples decreased throughout storage (p < 0.05. All factors were able to enhance astaxanthin degradation during 40 days of storage. With increasing storage time, the progressive formation of primary and secondary oxidation products were found in all samples as evidenced by the increases in both peroxide values (PV and thiobarbituric acid reactive substances (TBARS (p < 0.05. Light, air and temperatures therefore had the marked effect on astaxanthin degradation and lipid oxidation in shrimp oils during the extended storage.

  12. Criticality studies for dry storage cask

    International Nuclear Information System (INIS)

    Krishnani, P.D.; Srinivasan, K.R.

    1993-01-01

    Spent nuclear fuel from Tarapur Atomic Power Station (TAPS) is stored in a storage pool located inside the reactor building. The capacity of this pool was initially to meet storage requirements of 528 bundles which was later augmented from time to time. Since the enhanced capacity was also getting exhausted, setting up of a storage pool away from reactor was envisaged. As an interim measure, the dry storage casks were designed to store the spent fuel already cooled for a few years in the storage pools. If water enters the cask, the cask interior may be covered with steam water or air-water mixture. This paper gives the results of criticality calculations for storage cask under various conditions of steam water mixture, using the computer code LWRBOX. In these calculations, it has been assumed that the cask contains the most reactive fuel assemblies of reload-1 at zero burnup. It also gives the comparison of some of the results with General Electric (GE) calculations. (author). 3 refs., 1 fig., 2 tabs

  13. Microbial Life in an Underground Gas Storage Reservoir

    Science.gov (United States)

    Bombach, Petra; van Almsick, Tobias; Richnow, Hans H.; Zenner, Matthias; Krüger, Martin

    2015-04-01

    While underground gas storage is technically well established for decades, the presence and activity of microorganisms in underground gas reservoirs have still hardly been explored today. Microbial life in underground gas reservoirs is controlled by moderate to high temperatures, elevated pressures, the availability of essential inorganic nutrients, and the availability of appropriate chemical energy sources. Microbial activity may affect the geochemical conditions and the gas composition in an underground reservoir by selective removal of anorganic and organic components from the stored gas and the formation water as well as by generation of metabolic products. From an economic point of view, microbial activities can lead to a loss of stored gas accompanied by a pressure decline in the reservoir, damage of technical equipment by biocorrosion, clogging processes through precipitates and biomass accumulation, and reservoir souring due to a deterioration of the gas quality. We present here results from molecular and cultivation-based methods to characterize microbial communities inhabiting a porous rock gas storage reservoir located in Southern Germany. Four reservoir water samples were obtained from three different geological horizons characterized by an ambient reservoir temperature of about 45 °C and an ambient reservoir pressure of about 92 bar at the time of sampling. A complementary water sample was taken at a water production well completed in a respective horizon but located outside the gas storage reservoir. Microbial community analysis by Illumina Sequencing of bacterial and archaeal 16S rRNA genes indicated the presence of phylogenetically diverse microbial communities of high compositional heterogeneity. In three out of four samples originating from the reservoir, the majority of bacterial sequences affiliated with members of the genera Eubacterium, Acetobacterium and Sporobacterium within Clostridiales, known for their fermenting capabilities. In

  14. Storage mite contamination of commercial dry dog food in south-eastern Australia.

    Science.gov (United States)

    Hibberson, C E; Vogelnest, L J

    2014-06-01

    To evaluate contamination of unopened and opened stored sources of commercial dry dog food by viable storage mites. Prospective laboratory and field study. Samples were collected from nine brands of previously unopened bags (new bags) of dry food and 20 field sources of stored dry food in homes in Sydney and Canberra, Australia. All samples were initially examined for the presence of mites using a stereo-binocular microscope and then placed in separate filter-paper-sealed containers. Field samples were incubated at an average temperature of 29°C and 78% relative humidity (RH) for 5 weeks and then at average 26°C/83% RH for 8 weeks. Paired new-bag samples were stored under room conditions (average 23°C/47% RH) and controlled incubator conditions (average 26°C/80% RH) for 6 weeks. All samples were thoroughly examined for mites, mite eggs and visible mould once weekly using a stereo-binocular microscope. Storage mites were not visualised in any of the field samples or in new-bag samples stored at room temperature. Storage mites, identified as Tyrophagus putrescentiae, were visualised in increasing numbers in seven of nine new-bag samples after incubation, with first mites and then eggs evident after 3 weeks of incubation. We confirmed the presence of viable storage mites in a range of previously unopened commercial dry dog foods in Australia and confirmed the possibility of heavy storage mite contamination for dry food stored under conditions of moderate temperature and high humidity. These findings have relevance to storage mite and/or dust mite sensitivity in canine atopic dermatitis. © 2014 Australian Veterinary Association.

  15. Stability of selected serum hormones and lipids after long-term storage in the Janus Serum Bank.

    Science.gov (United States)

    Gislefoss, Randi E; Grimsrud, Tom K; Mørkrid, Lars

    2015-04-01

    The potential value of a biobank depends on the quality of the samples, i.e. how well they reflect the biological or biochemical state of the donors at the time of sampling. Documentation of sample quality has become a particularly important issue for researchers and users of biobank studies. The aim of this study was to investigate the long-term stability of selected components: cholesterol, high density cholesterol (HDLC), low density cholesterol (LDLC), apolipoprotein A1 (apo-A1), apolipoprotein B (apo B), follicle stimulating hormone (FSH), luteinizing hormone (LH), prolactin (PRL), thyroid stimulating hormone (TSH) and free thyroxin (FT4). Samples, stored at -25°C, from 520 men aged 40-49 years at blood sampling distributed in equally sized groups (n=130) according to length of storage, 0, 4, 17 and 29 years, respectively, were used in a cross sectional design. The freshly collected serum samples were used as a reference group to calculate storage related changes. The differences between fresh samples and samples stored for 29 years were substantial for apo-A1 (+12%), apo-B (+22.3%), HDLC (-69.2%), LDLC (+31.3%), and PRL (-33.5%), while total cholesterol, FSH, LH, TSH and FT4 did not show any significant difference. The study showed large differences in serum level of the selected components. The lipids and apolipoproteins were all changed except for total cholesterol. Most hormones investigated (FSH, LH, TSH and FT4) proved to be stable after 29 years of storage while PRL showed sign of degradation. The observed differences are probably due to long-term storage effects and/or external factors (i.e. diet and smoking). Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  16. Effect of Frozen Storage Temperature on the Quality of Premium Ice Cream.

    Science.gov (United States)

    Park, Sung Hee; Jo, Yeon-Ji; Chun, Ji-Yeon; Hong, Geun-Pyo; Davaatseren, Munkhtugs; Choi, Mi-Jung

    2015-01-01

    The market sales of premium ice cream have paralleled the growth in consumer desire for rich flavor and taste. Storage temperature is a major consideration in preserving the quality attributes of premium ice cream products for both the manufacturer and retailers during prolonged storage. We investigated the effect of storage temperature (-18℃, -30℃, -50℃, and -70℃) and storage times, up to 52 wk, on the quality attributes of premium ice cream. Quality attributes tested included ice crystal size, air cell size, melting resistance, and color. Ice crystal size increased from 40.3 μm to 100.1 μm after 52 wk of storage at -18℃. When ice cream samples were stored at -50℃ or -70℃, ice crystal size slightly increased from 40.3 μm to 57-58 μm. Initial air cell size increased from 37.1 μm to 87.7 μm after storage at -18℃ for 52 wk. However, for storage temperatures of -50℃ and -70℃, air cell size increased only slightly from 37.1 μm to 46-47 μm. Low storage temperature (-50℃ and -70℃) resulted in better melt resistance and minimized color changes in comparison to high temperature storage (-18℃ and -30℃). In our study, quality changes in premium ice cream were gradually minimized according to decrease in storage temperature up to-50℃. No significant beneficial effect of -70℃ storage was found in quality attributes. In the scope of our experiment, we recommend a storage temperature of -50℃ to preserve the quality attributes of premium ice cream.

  17. The significance of sampling time in therapeutic drug monitoring of clozapine

    DEFF Research Database (Denmark)

    Jakobsen, M I; Larsen, J R; Svensson, C K

    2017-01-01

    OBJECTIVE: Therapeutic drug monitoring (TDM) of clozapine is standardized to 12-h postdose samplings. In clinical settings, sampling time often deviates from this time point, although the importance of the deviation is unknown. To this end, serum concentrations (s-) of clozapine and its metabolite...... N-desmethyl-clozapine (norclozapine) were measured at 12 ± 1 and 2 h postdose. METHOD: Forty-six patients with a diagnosis of schizophrenia, and on stable clozapine treatment, were enrolled for hourly, venous blood sampling at 10-14 h postdose. RESULTS: Minor changes in median percentage values were...

  18. In vitro toxicity of infusion sets depends on their composition, storage time and storage conditions.

    Science.gov (United States)

    Kozlovskaya, Luba; Popilski, Hen; Gorenbein, Pavel; Stepensky, David

    2015-07-15

    Disposable medical devices release toxic leachables during their clinical use. Specifically, the individual parts of the infusion sets (the drip chamber, tube, flashball and injection site) are composed of numerous chemical compounds that can reach the patients' systemic circulation and induce local and systemic toxic effects. We aimed to reveal the relative in vitro toxicity of infusion sets from the leading vendors that are used in Israel, and to determine its dependence on their design and storage time/conditions. We found that leachates of the rubber parts were more toxic than those of the other parts of the infusion sets. The measured toxicity was affected by the experimental settings: the cells, medium composition, exposure duration, and the type of assay applied for toxicity assessment. We recommend to use the capillary endothelium cells for in vitro toxicity testing of the infusion sets, and refrain from the use of the MTT test which is insufficiently reliable, and can lead to artefacts and incorrect conclusions. Further investigation is needed to identify the toxic leachables from the individual parts of the infusion sets, and to reveal the risk of their toxicity during the clinical use of the infusion sets. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. The effect of the storage time of the matrix precursor on the mechanical properties of the fiber composite

    Czech Academy of Sciences Publication Activity Database

    Rýglová, Šárka; Sucharda, Zbyněk; Balík, Karel

    2007-01-01

    Roč. 51, č. 2 (2007), s. 89-93 ISSN 0862-5468 R&D Projects: GA MPO FT-TA3/131 Institutional research plan: CEZ:AV0Z30460519 Keywords : polysiloxane resins * curing process * storage time Subject RIV: JI - Composite Materials Impact factor: 0.488, year: 2007

  20. Stability Analysis of Buffer Storage Large Basket and Temporary Storage Pre-packaging Basket Used in the Type B Radwaste Process Area

    International Nuclear Information System (INIS)

    Kim, Sung Kyun; Lee, Kune Woo; Moon, Jei Kwon

    2011-01-01

    The ITER radioactive waste (radwaste) treatment and storage systems are currently being designed to manage Type B, Type A and dust radwastes generated during the ITER machine operation. The Type B management system is to be in the hot cell building basement with temporary storage and the modular type storages outside the hot cell building for the pre-packed Type B radwaste during the ITER operation of 20 years. In order to store Type B radwaste components in onsite storage, the waste treatment chain process for Type B radwastes was developed as follows. First, Type B full components filled in a large basket are imported from Tokamak to the hot cell basement and they are stored in the buffer storage before treatment. Second, they are cut properly with a laser cutting machine or band saw machine and sliced waste parts are filled in a pre-packaging basket. Third, the sampling of Type B components is performed and then the tritium removal treatment is done in an oven to remove tritium from the waste surface and then the sampling is performed again. Forth, the characterization is performed by using a gamma spectrometry. Fifth, the pre-packaging operation is done to ensure the final packaging of the radwaste. Sixth, the pre-packaging baskets are stored in the temporary storage for 6 months and then they are sent to the extension storage and stored until export to host country. One of issues in the waste treatment scheme is to analyze the stacking stability of a stack of large baskets and pre-packaging baskets in the storage system. The baseline plan is to stack the large baskets in two layers in the buffer storage and to stack the pre-packaging baskets in three layers in the temporary storage and extension storage. In this study, the stacking stability analysis for the buffer storage large basket and temporary storage pre-packaging basket was performed for various stack failure modes

  1. Fast multichannel analog storage system

    International Nuclear Information System (INIS)

    Freytag, D.R.

    1982-11-01

    A Multichannel Analog Storage System based on a commercial 32-channel parallel in/serial out (PISO) analog shift register is described. The basic unit is a single width CAMAC module containing 512 analog cells and the associated logic for data storage and subsequent readout. At sampling rates of up to 30 MHz the signals are strobed directly into the PISO. At higher rates signals are strobed into a fast presampling stage and subsequently transferred in block form into an array of PISO's. Sampling rates of 300 MHz have been achieved with the present device and 1000 MHz are possible with improved signal drivers. The system is well suited for simultaneous handling of many signal channels with moderate numbers of samples in each channel. RMS noise over full scale signal has been measured as 1:3000 (approx. = 11 bit). However, nonlinearities in the response and differences in sensitivity of the analog cells require an elaborate calibration system in order to realize 11 bit accuracy for the analog information

  2. Effects of Starter Culture and Storage Temperature on Functional, Microbial and Sensory Characteristics of Kefir during Storage

    Directory of Open Access Journals (Sweden)

    Tayyebeh Sarlak

    2017-03-01

    Full Text Available The aim of this study was to investigate the effects of starters and storage temperature (4 ºC, 25 ºC on microbiological and physicochemical properties, volatile compounds and sensory evaluation of kefir. Kefirs produced by KFA and Chr. Hansen starters were stored at 4 ºC and 25 ºC for 40 days. pH and acidity at 4 ºC did not change (p ≥ 0.05, while at 25 ºC pH and total solid decreased as well as acidity. Concentrations of acetaldehyde and ethanol increased (p < 0.05. No significant differences (p ≥ 0.05 were observed in protein and non-protein-nitrogen for both samples. Sensory evaluation revealed that storage did not affect texture and color of samples at 4 ºC. Kefir produced by Chr. Hansen starter stored at 4 ºC had the highest acceptability until 40-day storage and was preferred by the panelists.

  3. Fast storage of nuclear quadrupole resonance signals

    International Nuclear Information System (INIS)

    Anferov, V.P.; Molchanov, S.V.; Levchun, O.D.

    1988-01-01

    Fast multichannel storage of nuclear quadrupole resonance (NQR) signals is described. Analog-to-digital converter, arithmetic-logical unit, internal memory device (IMD) selection-storage unit and control unit are the storage main units. The storage is based on 43 microcircuits and provides for record and storage of NQR-signals at the contributed operation with Mera-60 microcomputer. Time of analog-to-digital conversion and signal recording into IMD is ∼ 1 mks. Capacity of analog-to-digital converter constitutes 8-10 bits. IMD capacity is 4 K bitsx16. Number of storage channels is 4

  4. Storage tank materials for biodiesel blends; the analysis of fuel property changes

    Directory of Open Access Journals (Sweden)

    Nurul Komariah Leily

    2017-01-01

    Full Text Available Fuel stability is one of major problem in biodiesel application. Some of the physical properties of biodiesel are commonly changed during storage. The change in physico-chemical properties is strongly correlated to the stability of the fuel. This study is objected to observe the potential materials for biodiesel storage. The test was conducted in three kinds of tank materials, such as glass, HDPE, and stainless steel. The fuel properties are monitored in 12 weeks, while the sample was analyzed every week. Biodiesel used is palm oil based. The storage tanks were placed in a confined indoor space with range of temperature 27–34 °C. The relative humidity and sunshine duration on the location was also evaluated. The observed properties of the fuel blends were density, viscosity and water content. During 12 weeks of storage, the average density of B20 was changed very slightly in all tanks, while the viscosity was tend to increase sharply, especially in polimerics tank. Water content of B20 was increased by the increase of storage time especially in HDPE tank. In short period of storage, the biodiesel blends is found more stable in glass tank due to its versatility to prohibit oxidation, degradation, and its chemical resistance.

  5. Establishing conditions for the storage and elution of rabies virus RNA using FTA® cards

    Science.gov (United States)

    SAKAI, Takeo; ISHII, Ayako; SEGAWA, Takao; TAKAGI, Yukihiko; KOBAYASHI, Yuki; ITOU, Takuya

    2014-01-01

    The Flinders Technology Associates filter paper cards (FTA® cards) can be used to store nucleic acid from various samples and are easily portable. However, RNA is physicochemically unstable compared with DNA, and appropriate methods have not been established for storage and extraction of RNA from FTA® cards. The present study investigated the optimum conditions for storage and elution of viral RNA (vRNA) using rabies virus (RABV) applied to FTA® cards. When TE buffer was used, the elution rates of vRNA increased with the length of the elution time. When the cards were stored at −80°C or −20°C, vRNA was stable over 3 months. Degradation of vRNAs occurred following storage at 4°C and room temperature, suggesting that RNA should be extracted from cards as soon as possible if no freezer is available. When we tried to amplify vRNA from RABV-infected animal brains applied to FTA® cards and stored at −80°C for 6 months, we did not detect any amplified products with the primer set for 964 bp of RABV N gene. However, we were able to detect amplified products by increasing the elution time of vRNA from FTA® cards from 30 min to 24 hr or by changing the primer sets to amplify 290 bp of N gene. Thus, we recommend extending the elution time for damaged or low concentration samples in FTA® cards. PMID:25648208

  6. Testing a groundwater sampling tool: Are the samples representative?

    International Nuclear Information System (INIS)

    Kaback, D.S.; Bergren, C.L.; Carlson, C.A.; Carlson, C.L.

    1989-01-01

    A ground water sampling tool, the HydroPunch trademark, was tested at the Department of Energy's Savannah River Site in South Carolina to determine if representative ground water samples could be obtained without installing monitoring wells. Chemical analyses of ground water samples collected with the HydroPunch trademark from various depths within a borehole were compared with chemical analyses of ground water from nearby monitoring wells. The site selected for the test was in the vicinity of a large coal storage pile and a coal pile runoff basin that was constructed to collect the runoff from the coal storage pile. Existing monitoring wells in the area indicate the presence of a ground water contaminant plume that: (1) contains elevated concentrations of trace metals; (2) has an extremely low pH; and (3) contains elevated concentrations of major cations and anions. Ground water samples collected with the HydroPunch trademark provide in excellent estimate of ground water quality at discrete depths. Groundwater chemical data collected from various depths using the HydroPunch trademark can be averaged to simulate what a screen zone in a monitoring well would sample. The averaged depth-discrete data compared favorably with the data obtained from the nearby monitoring wells

  7. Toward a New Test of the Relativistic Time Dilation Factor by Laser Spectroscopy of Fast Ions in a Storage Ring

    International Nuclear Information System (INIS)

    Saathoff, G.; Eisenbarth, U.; Hannemann, S.; Hoog, I.; Huber, G.; Karpuk, S.; Krohn, S.; Lassen, J.; Schwalm, D.; Weidemueller, M.; Wolf, A.; Gwinner, G.

    2003-01-01

    The frequency measurement of Doppler-shifted optical lines of ions circulating in a storage ring at high speed permits a sensitive test of the relativistic Doppler-formula and, hence, the time dilation factor γ SR of special relativity. Previous measurements at the storage ring TSR with 7 Li + at v=0.065c gave a new, improved limit, but were hampered by the large observed linewidth, exceeding the natural width 15-fold. Recently we have identified the broadening to be caused by velocity-changing processes in the storage ring. Saturation spectroscopy has proven to be largely immune against these effects and has yielded linewidths only a few MHz larger than the natural one. This is the major ingredient for an improved test of γ SR , which is now under way.

  8. Toward a New Test of the Relativistic Time Dilation Factor by Laser Spectroscopy of Fast Ions in a Storage Ring

    Energy Technology Data Exchange (ETDEWEB)

    Saathoff, G.; Eisenbarth, U.; Hannemann, S. [Max-Planck-Institut fuer Kernphysik (Germany); Hoog, I.; Huber, G.; Karpuk, S. [Universitaet Mainz, Institut fuer Physik (Germany); Krohn, S. [Max-Planck-Institut fuer Kernphysik (Germany); Lassen, J. [Universitaet Mainz, Institut fuer Physik (Germany); Schwalm, D.; Weidemueller, M.; Wolf, A.; Gwinner, G. [Max-Planck-Institut fuer Kernphysik (Germany)

    2003-03-15

    The frequency measurement of Doppler-shifted optical lines of ions circulating in a storage ring at high speed permits a sensitive test of the relativistic Doppler-formula and, hence, the time dilation factor {gamma}{sub SR} of special relativity. Previous measurements at the storage ring TSR with {sup 7}Li{sup +} at v=0.065c gave a new, improved limit, but were hampered by the large observed linewidth, exceeding the natural width 15-fold. Recently we have identified the broadening to be caused by velocity-changing processes in the storage ring. Saturation spectroscopy has proven to be largely immune against these effects and has yielded linewidths only a few MHz larger than the natural one. This is the major ingredient for an improved test of {gamma}{sub SR}, which is now under way.

  9. Improved synthesis and hydrogen storage of a microporous metal-organic framework material

    International Nuclear Information System (INIS)

    Cheng Shaojuan; Liu Shaobing; Zhao Qiang; Li Jinping

    2009-01-01

    A microporous metal-organic framework MOF-5 [Zn 4 O(BDC) 3 , BDC = 1,4-benzenedicarboxylic] was synthesized with and without H 2 O 2 by improved methods based on the previous studies. The obtained materials were characterized by X-ray diffraction, scanning electron microscopy and nitrogen adsorption, and their hydrogen storage capacities were measured. The synthesis experiments showed that H 2 O 2 favored the growth of high quality sample, large pore volume and high specific surface area. The measurements of hydrogen storage indicated that the sample with higher specific surface area and large pore volume showed better hydrogen storage behavior than other samples. It was suggested that specific surface area and pore volume influenced the capacity of hydrogen storage for MOF-5 material.

  10. Trial production of ceramic heat storage unit and study on thermal properties and thermal characteristics of the heat storage unit. Mixed salts of Na2CO3, MgCl2 and CaCl2 as heat storage medium

    International Nuclear Information System (INIS)

    Shiina, Yasuaki

    1998-12-01

    Heat storage technique of high temperature and high density latent heat can be applied to an accumulator of heat generated by nuclear power plant in the night and to a thermal load absorber. For the practical use of the heat storage technique, it is important to improve heat exchange characteristics between heat storage medium, such as molten salts, and heat transfer fluid because of low thermal conductivity of the molten salts, to improve durability among molten salt and structure materials and to develop the molten salt with stable thermal properties for a long period. Considering the possibility for the improvement of heat exchange characteristics of phase change heat storage system by absorbing molten salt in porous ceramics with high thermal conductivity, high temperature proof and high resistance to corrosion, several samples of the ceramics heat storage unit were made. Basic characteristics of the samples (strength, thermal properties, temperature characteristics during phase change) were measured experimentally and analytically to study the utility and applicability of the samples for the heat storage system. The results show that the heat storage unit should be used in inactive gas condition because water in the air absorbed in the molten salts would yield degeneration of properties and deterioration of strength and that operation temperature should be confined near fusion temperature because some molten salts would be vaporized and mass would be decreased in considerable high temperature. The results also show that when atmospheric temperature changes around the melting temperature, change in ceramic temperature becomes small. This result suggests the possibility that ceramic heat storage unit could be used as thermal load absorber. (J.P.N.)

  11. Influence of cooking methods and storage time on lipid and protein oxidation and heterocyclic aromatic amines production in bacon.

    Science.gov (United States)

    Soladoye, O P; Shand, P; Dugan, M E R; Gariépy, C; Aalhus, J L; Estévez, M; Juárez, M

    2017-09-01

    This study aimed to examine the influence of cooking methods and pre-determined refrigerated storage days on the production of lipid oxidation (TBARS), protein oxidation (PROTOX) and heterocyclic aromatic amines (HAA) in bacon. Forty-four pork bellies selected from pigs varying in breed, sex and diets to introduce variability in composition were processed as bacon. Sliced-bacon was stored at 4°C either for 2 or 28days and these storage groups were cooked either with microwave or frying pan. Microwave led to significantly higher PROTOX (P0.05) by the cooking methods and storage times. Similarly, the fatty acid composition of pork belly did not significantly influence the production of HAA, TBARS and PROTOX produced in bacon during cooking. Overall, microwave cooking had lesser impact on the production of carcinogenic compounds in bacon with only minor impact on sensory attributes. Copyright © 2017. Published by Elsevier Ltd.

  12. INVESTIGATION OF THE PROPERTIES OF MARMALADE WITH PLANT CRYOADDITIVES DURING STORAGE

    Directory of Open Access Journals (Sweden)

    N. Shmatchenko

    2018-04-01

    Full Text Available This article presents the results of studies of the properties of marmalade with natural plant cryoadditives during storage for 3 months (90 days. To improve the organoleptic characteristics and antioxidant properties of marmalade, plant additives of cryogenic origin were used, namely cryopastes from quince, apple, carrot, pumpkin, grapes, and cryopowders from rose hips, sea buckthorn, and grapes. It is shown that the use of plant cryoadditives makes it possible to increase the biological value and antioxidant properties of new types of marmalade. For new types of marmalade with cryoadditives, during its shelf life, these properties have not been studied earlier. However, it should be noted that such studies are necessary and relevant for solving the problem of preserving the quality indicators and antioxidant capacity of marmalade with cryoadditives. New kinds of marmalade have high organoleptic characteristics during the whole storage period. It is shown that the storage conditions of marmalade, according to current regulatory documentation, are suitable for new marmalade products, since the physico-chemical and microbiological indicators vary, but remain within acceptable limits. Thus, the moisture content decreases to almost 31%, the acidity rises by 12–16%, compared to freshly prepared samples. The content of reducing substances increases by 30–64%. It is determined that the value of the antioxidant capacity of all the samples developed is much higher – almost 2.3–8 times than the same figure for the control sample. After the storage period, the antioxidant capacity is reduced by 15–35%, but this data also significantly exceeds the antioxidant capacity of the control sample. Storage of marmalade with cryopastes and cryopowders for 90 days is possible, since all the basic physico-chemical, microbiological, and organoleptic indicators at the end of shelf life meet the requirements. Indicators of antioxidant capacity for them also

  13. Spent fuel storage

    International Nuclear Information System (INIS)

    Huppert

    1976-01-01

    To begin with, the author explains the reasons for intermediate storage of fuel elements in nuclear power stations and in a reprocessing plant and gives the temperature and radioactivity curves of LWR fuel elements after removal from the reactor. This is followed by a description of the facilities for fuel element storage in a reprocessing plant and of their functions. Futher topics are criticality and activity control, the problem of cooling time and safety systems. (HR) [de

  14. Electric energy storage - Overview of technologies

    International Nuclear Information System (INIS)

    Boye, Henri

    2013-01-01

    Energy storage is a challenging and costly process, as electricity can only be stored by conversion into other forms of energy (e.g. potential, thermal, chemical or magnetic energy). The grids must be precisely balanced in real time and it must be made sure that the cost of electricity is the lowest possible. Storage of electricity has many advantages, in centralized mass storages used for the management of the transmission network, or in decentralized storages of smaller dimensions. This article presents an overview of the storage technologies: mechanical storage in hydroelectric and pumped storage power stations, compressed air energy storage (CAES), flywheels accumulating kinetic energy, electrochemical batteries with various technologies, traditional lead acid batteries, lithium ion, sodium sulfur (NaS) and others, including vehicle to grid, sensible heat thermal storage, superconducting magnetic energy storage (SMES), super-capacitors, conversion into hydrogen... The different technologies are compared in terms of cost and level of maturity. The development of intermittent renewable energies will result in a growing need for mechanisms to regulate energy flow and innovative energy storage solutions seem well positioned to develop. (author)

  15. Intransience of functional components and distinctive properties of amla (Indian gooseberry) ice cream during short-term storage.

    Science.gov (United States)

    Goraya, Rajpreet Kaur; Bajwa, Usha

    2018-05-01

    Inclusion of processed amla have been found to enhance the functional properties and nutritional value of ice cream by augmenting the fiber content, total phenols, tannins, ascorbic acid and antioxidant activity. The present investigation assessed the changes in these constituents, color values (L, a* and b*), melting rate, sensory scores and microbiological quality of ice cream containing amla shreds, pulp, preserve, candy and powder during 60 days' storage at - 18 to - 20 °C. The total solids increased slightly whereas the antioxidant activity, total phenols, ascorbic acid and tannins decreased on storage. The L values declined whereas a* and b* values amplified, the rate of change being highest in candy containing sample followed by preserve. The first drip time of all the samples increased whereas melting rate decreased. The overall acceptability scores declined non significantly. Standard plate count of all the ice cream samples decreased significantly whereas yeast and molds were not detected throughout the storage. The psychrophiles were not spotted up to 30 days, thereafter, a small increase was observed.

  16. Final work plan : indoor air and ambient air sampling near the former CCC/USDA grain storage facility in Everest, Kansas.

    Energy Technology Data Exchange (ETDEWEB)

    LaFreniere, L. M. (Environmental Science Division)

    2010-05-24

    The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) operated a grain storage facility at the western edge of Everest, Kansas, from the early 1950s to the early 1970s. Sampling by the Kansas Department of Health and Environment (KDHE) in 1997 resulted in the detection of carbon tetrachloride in one domestic well (the Nigh well) northwest of the former facility. On behalf of the CCC/USDA, Argonne National Laboratory subsequently conducted a series of investigations to characterize the contamination (Argonne 2003, 2006a,b,c). Automatic, continuous monitoring of groundwater levels began in 2002 and is ongoing at six locations. The results have consistently indicated groundwater flow toward the north-northwest from the former CCC/USDA property to the Nigh property, then west-southwest from the Nigh property to the intermittent creek. Sitewide periodic groundwater and surface water sampling with analysis for volatile organic compounds (VOCs) began in 2008. Argonne's combined data indicate no significant downgradient extension of contamination since 2000. At present, the sampling is annual, as approved by the KDHE (2009) in response to a plan developed for the CCC/USDA (Argonne 2009). This document presents a plan for collecting indoor air samples in homes located along and adjacent to the defined extent of the carbon tetrachloride contamination. The plan was requested by the KDHE. Ambient air samples to represent the conditions along this pathway will also be taken. The purpose of the proposed work is to satisfy KDHE requirements and to collect additional data for assessing the risk to human health due to the potential upward migration of carbon tetrachloride and its primary degradation product (chloroform) into homes located in close proximity to the former grain storage facility, as well as along and within 100 ft laterally from the currently defined plume emanating from the former Everest facility. Investigation of the indoor air

  17. The design of data storage system based on Lustre for EAST

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Feng, E-mail: wangfeng@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Chen, Ying; Li, Shi [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Yang, Fei [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Department of Computer Science, Anhui Medical University, Hefei, Anhui (China); Xiao, Bingjia [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); School of Nuclear Science and Technology, University of Science and Technology of China, Hefei, Anhui (China)

    2016-11-15

    Highlights: • A high performance data storage system based on Lustre and InfiniBand network has been designed and implemented on EAST tokamak. • The acquired data are stored into MDSplus database continuously on Lustre storage system during discharge. • The high performance computing clusters are interconnected with data acquisition and storage system by Lustre and InfiniBand network. - Abstract: The quasi-steady state operation is one of the main purposes of EAST tokamak, and more than 400 s discharge pulse has been achieved in the past campaigns. The acquired data amount increases continuously with the discharge length. At the same time to meet the requirement of the upgrade and improvement of the diagnostic systems, more and more data acquisition channels have come into service. Some new diagnostic systems require high sampling rate data acquisition more than 10MSPS. In the last campaign 2014, the data streaming is about 2000MB/s and the total data amount is more than 100TB. How to store the huge data continuously becomes a big problem. A new data storage system based on Lustre has been designed to solve the problem. All the storage nodes and servers are connected to InfiniBand FDR 56Gbps network. The maximum parallel throughput of the total storage system is about 10GB/s. It is easy to expand the storage system by adding I/O nodes when more capacity and performance are required in the future. The new data storage system will be applied in the next campaign of EAST. The system details are given in the paper.

  18. The design of data storage system based on Lustre for EAST

    International Nuclear Information System (INIS)

    Wang, Feng; Chen, Ying; Li, Shi; Yang, Fei; Xiao, Bingjia

    2016-01-01

    Highlights: • A high performance data storage system based on Lustre and InfiniBand network has been designed and implemented on EAST tokamak. • The acquired data are stored into MDSplus database continuously on Lustre storage system during discharge. • The high performance computing clusters are interconnected with data acquisition and storage system by Lustre and InfiniBand network. - Abstract: The quasi-steady state operation is one of the main purposes of EAST tokamak, and more than 400 s discharge pulse has been achieved in the past campaigns. The acquired data amount increases continuously with the discharge length. At the same time to meet the requirement of the upgrade and improvement of the diagnostic systems, more and more data acquisition channels have come into service. Some new diagnostic systems require high sampling rate data acquisition more than 10MSPS. In the last campaign 2014, the data streaming is about 2000MB/s and the total data amount is more than 100TB. How to store the huge data continuously becomes a big problem. A new data storage system based on Lustre has been designed to solve the problem. All the storage nodes and servers are connected to InfiniBand FDR 56Gbps network. The maximum parallel throughput of the total storage system is about 10GB/s. It is easy to expand the storage system by adding I/O nodes when more capacity and performance are required in the future. The new data storage system will be applied in the next campaign of EAST. The system details are given in the paper.

  19. Superconducting magnetic energy storage

    International Nuclear Information System (INIS)

    Rogers, J.D.

    1976-01-01

    Fusion power production requires energy storage and transfer on short time scales to create confining magnetic fields and for heating plasmas. The theta-pinch Scyllac Fusion Test Reactor (SFTR) requires 480 MJ of energy to drive the 5-T compression field with a 0.7-ms rise time. Tokamak Experimental Power Reactors (EPR) require 1 to 2 GJ of energy with a 1 to 2-s rise time for plasma ohmic heating. The design, development, and testing of four 300-kJ energy storage coils to satisfy the SFTR needs are described. Potential rotating machinery and homopolar energy systems for both the Reference Theta-Pinch Reactor (RTPR) and tokamak ohmic-heating are presented

  20. Lipid oxidation, color changes and volatiles production in irradiated pork sausage with different fat content and packaging during storage

    International Nuclear Information System (INIS)

    Jo, C.; Lee, J.I.; Ahn, D.U.

    1999-01-01

    Effects of irradiation on lipid oxidation, color and volatiles production in pork sausages with different fat content and packaging were determined. Sausages (with 4.7, 10.5 and 15.8% fat content) were sliced and vacuum-packaged either in oxygen-permeable or impermeable bags, irradiated (0 or 4.5 kGy) and stored at 4°C for 7 days. Lipid oxidation, color and volatiles productions were analyzed at 0, 3 and 7 days of storage. TBARS (2-thiobarbituric acid reactive substances) values of cooked pork sausages increased with the increase of fat content regardless of storage, irradiation or packaging types. Irradiated samples had higher TBARS than nonirradiated at 0 day but the difference disappeared during storage in both packaging types. Lightness of sausages (Hunter L-value) increased with the increase of fat content and storage time but was not affected by irradiation. In aerobic packaging, irradiation reduced Hunter a-values of pork sausages at 0 day but irradiation effect on a-value disappeared during storage. In vacuum packaging, however, irradiated samples had higher Hunter a-values than nonirradiated samples. Irradiation increased 1-heptene and total volatiles, but the amount of 1-heptene was not associated well with TBARS values of pork sausages. In both irradiated and nonirradiated pork sausages, aerobic packaging produced more volatiles than vacuum packaging during storage. It was concluded that irradiation and fat content had significant effects on lipid oxidation, color and volatiles production of cooked pork sausages during storage but that oxygen availability had a stronger effect than irradiation and fat content

  1. Troubleshooting vSphere storage

    CERN Document Server

    Preston, Mike

    2013-01-01

    This is a step-by-step example-oriented tutorial aimed at showing the reader how to troubleshoot a variety of vSphere storage problems, and providing the reader with solutions that can be completed with minimal effort and time in order to limit damage to work.If you are a vSphere administrator, this is the book for you. This book will provide you with 'need to know' information about the various storage transports that ESXi utilizes, the tools and techniques we can use to identify problems, and the fundamental knowledge and steps to take to troubleshoot storage-related issues. Prior knowledge

  2. Sampling methods for rumen microbial counts by Real-Time PCR techniques

    Directory of Open Access Journals (Sweden)

    S. Puppo

    2010-02-01

    Full Text Available Fresh rumen samples were withdrawn from 4 cannulated buffalo females fed a fibrous diets in order to quantify bacteria concentration in the rumen by Real-Time PCR techniques. To obtain DNA of a good quality from whole rumen fluid, eight (M1-M8 different pre-filtration methods (cheese cloths, glass-fibre and nylon filter in combination with various centrifugation speeds (1000, 5000 and 14,000 rpm were tested. Genomic DNA extraction was performed either on fresh or frozen samples (-20°C. The quantitative bacteria analysis was realized according to Real-Time PCR procedure for Butyrivibrio fibrisolvens reported in literature. M5 resulted the best sampling procedure allowing to obtain a suitable genomic DNA. No differences were revealed between fresh and frozen samples.

  3. Application of EPR spectroscopy to examine free radicals evolution during storage of the thermally sterilized Ungentum ophthalmicum.

    Science.gov (United States)

    Ramos, Paweł; Pilawa, Barbara

    2016-06-24

    Free radicals formed during thermal sterilization of the Ungentum ophthalmicum were examined by an X-band EPR spectroscopy. The influence of storage time (15 min; 1, 2 and 3 days after heating) on free radical properties and concentrations in this sample was determined. Thermal sterilization was done according to the pharmaceutical norms. The first-derivative EPR spectra with g-values about 2 were measured with magnetic modulation of 100 kHz in the range of microwave power 2.2-70 mW. The changes of amplitudes (A) and linewidths (ΔB pp ) with microwave powers were evaluated. Free radicals in concentration ∼10 17 spin/g were formed during heating of the tested Ungentum. Free radical concentration decreased with increase in storage time, and reached values ∼10 17 spin/g after 3 days from sterilization. The tested U. ophthalmicum should not be sterilized at a temperature of 160 °C because of the free radicals formation, or it should be used 3 days after heating, when free radicals were considerably quenched. Free radical properties remain unchanged during storage of the Ungentum. The EPR lines of the U. ophthalmicum were homogeneously broadened and their linewidths (ΔB pp ) increased with increase in microwave power. EPR spectroscopy is useful to examine free radicals to optimize sterilization process and storage conditions of ophthalmologic samples.

  4. 14C measurement: effect of variations in sample preparation and storage on the counting efficiency for 14C using a carbo-sorb/permafluor E+ liquid scintillation cocktail

    International Nuclear Information System (INIS)

    Kramer, S.J.; Milton, G.M.; Repta, C.J.W.

    1995-06-01

    The effect of variations in sample preparation and storage on the counting efficiency for 14 C using a Carbo-Sorb/PermafluorE+ liquid scintillation cocktail has been studied, and optimum conditions are recommended. (author). 2 refs., 2 tabs., 4 figs

  5. Reduction of pasteurization temperature leads to lower bacterial outgrowth in pasteurized fluid milk during refrigerated storage: a case study.

    Science.gov (United States)

    Martin, N H; Ranieri, M L; Wiedmann, M; Boor, K J

    2012-01-01

    Bacterial numbers over refrigerated shelf-life were enumerated in high-temperature, short-time (HTST) commercially pasteurized fluid milk for 15 mo before and 15 mo after reducing pasteurization temperature from 79.4°C (175°F) [corrected] to 76.1°C (169°F). Total bacterial counts were measured in whole fat, 2% fat, and fat-free milk products on the day of processing as well as throughout refrigerated storage (6°C) at 7, 14, and 21 d postprocessing. Mean total bacterial counts were significantly lower immediately after processing as well as at 21 d postprocessing in samples pasteurized at 76.1°C versus samples pasteurized at 79.4°C. In addition to mean total bacterial counts, changes in bacterial numbers over time (i.e., bacterial growth) were analyzed and were lower during refrigerated storage of products pasteurized at the lower temperature. Lowering the pasteurization temperature for unflavored fluid milk processed in a commercial processing facility significantly reduced bacterial growth during refrigerated storage. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  6. Effect of Mixing Time and Storage Condition on Characterization of Heparinoid Admixtures with Corticosteroids.

    Science.gov (United States)

    Sugiyama, Ikumi; Takahashi, Namiki; Sadzuka, Yasuyuki

    2016-01-01

    In dermatologic therapy, several external preparations formulated as ointments or creams are prescribed. And they are often admixture to improve patient compliance. In this study, we prepared admixtures of moisturizer with steroids and examined their usability and the amount of principal agent in formulations, particularly focusing on the moisturizer content. Four heparinoid semisolid formulations were selected: Hirudoid ® soft ointment 0.3% (Formulation A) and 3 generic agents [(Besoften ® oil-based cream 0.3% (Formulation B), Kuradoido ® ointment 0.3% (Formulation C), and Hepadaerm ointment 0.3% (Formulation D)], and Antebate ® ointment 0.05% (Formulation E) were used as steroids. Formulation A and B are water-in-oil emulsions, and Formulation C and D are oil-in-water emulsions. Admixtures looked like to be mixed uniformly by visual observation. In the examination of heparinoid amount, admixture A+E and B+E were mixed uniformly. On the other hand, admixture C+E was remarkable un-uniformly. It was speculated that the emulsification of formulation C was broken. The phenomenon was supported by the result of malleability. After 8 weeks storage, the heparinoid ratio in each formulation could be expressed as follows: Admixture B≥Admixture A>Admixture C=Admixture D. A suitable storage temperature was 4°C. The results of physicochemical data analysis reveal the formulations composed of water-in-oil cream, i.e., Formulation A and Formulation B, to be the optimal choices for mixing with steroid ointments. Mixing time and storage conditions may be optimized to solve pharmaceutical problems. Moreover, understanding the emulsion type and character of semisolid formulations can expand the range of formulation options.

  7. Pre-analytical sample quality: metabolite ratios as an intrinsic marker for prolonged room temperature exposure of serum samples.

    Directory of Open Access Journals (Sweden)

    Gabriele Anton

    Full Text Available Advances in the "omics" field bring about the need for a high number of good quality samples. Many omics studies take advantage of biobanked samples to meet this need. Most of the laboratory errors occur in the pre-analytical phase. Therefore evidence-based standard operating procedures for the pre-analytical phase as well as markers to distinguish between 'good' and 'bad' quality samples taking into account the desired downstream analysis are urgently needed. We studied concentration changes of metabolites in serum samples due to pre-storage handling conditions as well as due to repeated freeze-thaw cycles. We collected fasting serum samples and subjected aliquots to up to four freeze-thaw cycles and to pre-storage handling delays of 12, 24 and 36 hours at room temperature (RT and on wet and dry ice. For each treated aliquot, we quantified 127 metabolites through a targeted metabolomics approach. We found a clear signature of degradation in samples kept at RT. Storage on wet ice led to less pronounced concentration changes. 24 metabolites showed significant concentration changes at RT. In 22 of these, changes were already visible after only 12 hours of storage delay. Especially pronounced were increases in lysophosphatidylcholines and decreases in phosphatidylcholines. We showed that the ratio between the concentrations of these molecule classes could serve as a measure to distinguish between 'good' and 'bad' quality samples in our study. In contrast, we found quite stable metabolite concentrations during up to four freeze-thaw cycles. We concluded that pre-analytical RT handling of serum samples should be strictly avoided and serum samples should always be handled on wet ice or in cooling devices after centrifugation. Moreover, serum samples should be frozen at or below -80°C as soon as possible after centrifugation.

  8. Storage Conditions of Conjugated Reagents Can Impact Results of Immunogenicity Assays

    Directory of Open Access Journals (Sweden)

    Robert J. Kubiak

    2016-01-01

    Full Text Available Consistent performance of anti-drug antibody (ADA assays through all stages of clinical development is critical for the assessment of immunogenicity and interpretation of PK, PD, safety, and efficacy. The electrochemiluminescent assays commonly employed for ADA measurement use drug conjugated with ruthenium and biotin to bind ADA in samples. Here we report an association between high nonspecific ADA responses in certain drug-naïve individuals and the storage buffer of the conjugated reagents used in a monoclonal antibody ADA assay. Ruthenylated reagents stored in phosphate-buffered saline (PBS buffer had increased levels of aggregate and produced variable and high baseline responses in some subjects. Reagents stored in a histidine-sucrose buffer (HSB had lower aggregate levels and produced low sample responses. In contrast to PBS, conjugated reagents formulated in HSB remained low in aggregate content and in sample response variability after 5 freeze/thaw cycles. A reagent monitoring control (RMC serum was prepared for the real-time evaluation of conjugated reagent quality. Using appropriate buffers for storage of conjugated reagents together with RMCs capable of monitoring of reagent aggregation status can help ensure consistent, long-term performance of ADA methods.

  9. Random sampling of evolution time space and Fourier transform processing

    International Nuclear Information System (INIS)

    Kazimierczuk, Krzysztof; Zawadzka, Anna; Kozminski, Wiktor; Zhukov, Igor

    2006-01-01

    Application of Fourier Transform for processing 3D NMR spectra with random sampling of evolution time space is presented. The 2D FT is calculated for pairs of frequencies, instead of conventional sequence of one-dimensional transforms. Signal to noise ratios and linewidths for different random distributions were investigated by simulations and experiments. The experimental examples include 3D HNCA, HNCACB and 15 N-edited NOESY-HSQC spectra of 13 C 15 N labeled ubiquitin sample. Obtained results revealed general applicability of proposed method and the significant improvement of resolution in comparison with conventional spectra recorded in the same time

  10. Influence of packaging and storage conditions on quality parameters and shelf life of solar-dried banana

    Directory of Open Access Journals (Sweden)

    Nina Phothapaeree

    2017-04-01

    Full Text Available Effects of packaging materials (metalized or polylactic acid, PLA, based pouches, storage temperatures (30-50°C and time (up to 6 months on quality of solar-dried banana were investigated. At 30°C in both packaging materials, change in moisture content, water activity (a w and hardness were minimal while darkening of the surface color progressed. No microbial spoilage was found. Hedonic scores of color, flavor, taste, texture and overall acceptance of the 6th month aged samples were lowest (p≤0.05. Based on the sensory test, product packed in both packaging materials had shelf life of 5 months at 30°C. Higher storage temperature greatly induced time-dependent decrease in moisture content and a w with an increase in hardness, especially for the samples in PLA-based pouches. Fractional conversion model was used to predicted time-dependent change in total color difference (ΔE (R2 ≥ 0.84. Temperature dependence of the rate constant followed Arrhenius-type relationship (R2 ≥ 0.99.

  11. Influence of the addition and storage time of crude extract of tea leaves (camellia sinensis l.) toward value of free fatty acid in crude palm oil

    Science.gov (United States)

    Erwin; Wahifiyah, E.; Hairani, R.; Panggabean, A. S.

    2018-04-01

    The purpose of this study was to determine the effect of the crude extract of tea leaves (Camellia sinensis L.) and storage time on the content of free fatty acid in palm oil. The dried tea leaves were macerated and concentrated by rotary evaporator. The extract obtained was added to crude palm oil with various added mass of the extract and various storage times. Phytochemical tests indicated the presence of secondary metabolites including alkaloids, triterpenoids, steroids, phenolics and flavonoids. The ANOVA test showed a decrease in free fatty acid content in crude palm oil with the addition of tea leaves extract. The LSD (Least Significant Difference) test showed the best influence on ALB of palm oil is on the total extract mass of 2 grams and the storage time of 20 days.

  12. Cyclic high temperature heat storage using borehole heat exchangers

    Science.gov (United States)

    Boockmeyer, Anke; Delfs, Jens-Olaf; Bauer, Sebastian

    2016-04-01

    The transition of the German energy supply towards mainly renewable energy sources like wind or solar power, termed "Energiewende", makes energy storage a requirement in order to compensate their fluctuating production and to ensure a reliable energy and power supply. One option is to store heat in the subsurface using borehole heat exchangers (BHEs). Efficiency of thermal storage is increasing with increasing temperatures, as heat at high temperatures is more easily injected and extracted than at temperatures at ambient levels. This work aims at quantifying achievable storage capacities, storage cycle times, injection and extraction rates as well as thermal and hydraulic effects induced in the subsurface for a BHE storage site in the shallow subsurface. To achieve these aims, simulation of these highly dynamic storage sites is performed. A detailed, high-resolution numerical simulation model was developed, that accounts for all BHE components in geometrical detail and incorporates the governing processes. This model was verified using high quality experimental data and is shown to achieve accurate simulation results with excellent fit to the available experimental data, but also leads to large computational times due to the large numerical meshes required for discretizing the highly transient effects. An approximate numerical model for each type of BHE (single U, double U and coaxial) that reduces the number of elements and the simulation time significantly was therefore developed for use in larger scale simulations. The approximate numerical model still includes all BHE components and represents the temporal and spatial temperature distribution with a deviation of less than 2% from the fully discretized model. Simulation times are reduced by a factor of ~10 for single U-tube BHEs, ~20 for double U-tube BHEs and ~150 for coaxial BHEs. This model is then used to investigate achievable storage capacity, injection and extraction rates as well as induced effects for

  13. Temperature dependence of the calibration factor of radon and radium determination in water samples by SSNTD

    CERN Document Server

    Hunyadi, I; Hakl, J; Baradacs, E; Dezso, Z

    1999-01-01

    The sensitivity of a sup 2 sup 2 sup 6 Ra determination method of water samples by SSNTD was measured as a function of storage temperature during exposure. The method is based on an etched track type radon monitor, which is closed into a gas permeable foil and is immersed in the water sample. The sample is sealed in a glass vessel and stored for an exposure time of 10-30 days. The sensitivity increased more than a factor of two when the storage temperature was raised from 2 deg. C to 30 deg. C. Temperature dependence of the partition coefficient of radon between water and air provides explanation for this dependence. For practical radio- analytical application the temperature dependence of the calibration factor is given by fitting the sensitivity data obtained by measuring sup 2 sup 2 sup 6 Ra standard solutions (in the activity concentration range of 0.1-48.5 kBq m sup - sup 3) at different storage temperatures.

  14. Comparison of control systems for the optimisation of ice storage in a dynamic real time electricity pricing environment

    International Nuclear Information System (INIS)

    Murphy, M.D.; O’Mahony, M.J.; Upton, J.

    2015-01-01

    Highlights: • A cold thermal energy storage system model was created and validated. • Pseudo real time electricity pricing was derived to represent the smart grid. • A demand side management optimisation algorithm was developed. • Demand side management algorithm performance was compared to a standard controller. • Overall the demand side management algorithm produced modest cost savings. - Abstract: The objective of this study was to assess the benefits of introducing a demand side management optimisation controller to a cold thermal storage ice bank. This controller consisted of an ice bank model, an air temperature forecast model and an optimisation algorithm. The financial and grid utilisation benefits produced by implementation of this controller over the current state of the art in ice bank load shifting control was tested in a day ahead real time electricity pricing forecast environment. This hypothetical real time electricity price was based on the cost of electricity in the Irish wholesale market. Multiple ice bank charge levels were simulated in order to quantify the performance of two control methods for varying operating conditions. First, the “standard controller” was based on the current modus operandi for ice bank systems where ice was generated for food cooling at night when the off-peak electricity tariff is available (00:00–08:00 h). Second, the “upgraded controller” was developed as a bespoke Demand Side Management control system for food refrigeration in a future electricity pricing environment. It consisted of a dual function load shifting optimisation algorithm, an ice bank model, and a predictive air temperature model. A preliminary study was also carried out to test the robustness of the controller’s performance in an uncertain real time electricity pricing forecast scenario. Both economic and grid management benefits were found by simulating the operation of the cold thermal storage load shifting controller in a

  15. Helium effects on tritium storage materials

    International Nuclear Information System (INIS)

    Moysan, I.; Contreras, S.; Demoment, J.

    2008-01-01

    For ten years French Tritium laboratories have been using metal hydride storage beds with LaNi 4 Mn for process gas (HDT mixture) absorption, desorption and for both short and long term storage. This material has been chosen because of its low equilibrium pressure and of its ability to retain decay helium 3 in its lattice. Aging effects on the thermodynamic behavior of LaNi 4 Mn have been investigated. Aging, due to formation of helium 3 in the lattice, decreases the desorption isotherm plateau pressure and shifts the α phase to the higher stoichiometries. Life time of the two kinds of tritium (and isotopes) storage vessels managed in the laboratory depends on these aging changes. The Tritium Long Term Storage (namely STLT) and the hydride storage vessel (namely FSH 400) are based on LaNi 4 Mn even though they are not used for the same applications. STLT contains LaNi 4 Mn in an aluminum vessel and is designed for long term pure tritium storage. The FSH 400 is composed of LaNi 4 Mn included within a stainless steel container. This design is aimed at storing low tritium content mixtures (less than 3% of tritium) and for supplying processes with HDT gas. Life time of the STLT can reach 12 years. Life time of the FSH 400 varies from 1.2 years to more than 25 years depending on the application. (authors)

  16. Helium effects on tritium storage materials

    Energy Technology Data Exchange (ETDEWEB)

    Moysan, I.; Contreras, S.; Demoment, J. [CEA Valduc, Service HDT, 21 - Is-sur-Tille (France)

    2008-07-15

    For ten years French Tritium laboratories have been using metal hydride storage beds with LaNi{sub 4}Mn for process gas (HDT mixture) absorption, desorption and for both short and long term storage. This material has been chosen because of its low equilibrium pressure and of its ability to retain decay helium 3 in its lattice. Aging effects on the thermodynamic behavior of LaNi{sub 4}Mn have been investigated. Aging, due to formation of helium 3 in the lattice, decreases the desorption isotherm plateau pressure and shifts the {alpha} phase to the higher stoichiometries. Life time of the two kinds of tritium (and isotopes) storage vessels managed in the laboratory depends on these aging changes. The Tritium Long Term Storage (namely STLT) and the hydride storage vessel (namely FSH 400) are based on LaNi{sub 4}Mn even though they are not used for the same applications. STLT contains LaNi{sub 4}Mn in an aluminum vessel and is designed for long term pure tritium storage. The FSH 400 is composed of LaNi{sub 4}Mn included within a stainless steel container. This design is aimed at storing low tritium content mixtures (less than 3% of tritium) and for supplying processes with HDT gas. Life time of the STLT can reach 12 years. Life time of the FSH 400 varies from 1.2 years to more than 25 years depending on the application. (authors)

  17. Time-dependent importance sampling in semiclassical initial value representation calculations for time correlation functions. II. A simplified implementation.

    Science.gov (United States)

    Tao, Guohua; Miller, William H

    2012-09-28

    An efficient time-dependent (TD) Monte Carlo (MC) importance sampling method has recently been developed [G. Tao and W. H. Miller, J. Chem. Phys. 135, 024104 (2011)] for the evaluation of time correlation functions using the semiclassical (SC) initial value representation (IVR) methodology. In this TD-SC-IVR method, the MC sampling uses information from both time-evolved phase points as well as their initial values, and only the "important" trajectories are sampled frequently. Even though the TD-SC-IVR was shown in some benchmark examples to be much more efficient than the traditional time-independent sampling method (which uses only initial conditions), the calculation of the SC prefactor-which is computationally expensive, especially for large systems-is still required for accepted trajectories. In the present work, we present an approximate implementation of the TD-SC-IVR method that is completely prefactor-free; it gives the time correlation function as a classical-like magnitude function multiplied by a phase function. Application of this approach to flux-flux correlation functions (which yield reaction rate constants) for the benchmark H + H(2) system shows very good agreement with exact quantum results. Limitations of the approximate approach are also discussed.

  18. Irradiation and Post-Irradiation Storage of Chicken: Effects on Fat and Proteins

    International Nuclear Information System (INIS)

    Abou-Tarboush, H.M.; Al-Kahtani, H.A.; Abou-Arab, A.A.; Atia, M.; Bajaber, A.S.; Ahmed, M.A.; El-Mojaddidi, M.A.

    1997-01-01

    Chicken were subjected to gamma irradiation doses of 2.5, 5.0, 7.5 and 10.0 KGy and post-irradiation storage of 21 days at 4±2º. The effects on fat and protein of chicken were studied. Rate of formation of total volatile basic-nitrogen was less in irradiated samples particularly in samples treated with 5.0KGy during the entire storage. Fatty acid profiles of chicken lipids were not significantly (P≤ 0.05) affected by irradiation especially at doses of 5.0 KGy. However, irradiation caused a large increase in thiobarbituric acid (TBA) values which continued gradually during storage. Changes in amino acids were minimal. Irradiated and unirradiated samples showed the appearance of protein subunits with molecular weights in the range of 10.0 to 88.0 and 10.0 to 67.0 KD, respectively. No changes were observed in the sarcoplasmic protein but the intensity of bands in all irradiated samples decreased after 21 days of storage

  19. Effect of Packaging Method and Storage Time on Physicochemical Characteristics of Dry-Cured Pork Neck Products at 10°C

    Directory of Open Access Journals (Sweden)

    Il-Suk Kim

    2014-11-01

    Full Text Available Dry-cured pork neck samples were stored at 10°C for 90 days under vacuum packaging (VP or modified atmosphere packaging (MAP; 25% CO2+75% N2 conditions. The pH, moisture, water activity, total aerobic bacteria, and Enterobacteriaceae counts of dry-cured pork neck products with MAP were significantly lower than those with VP (p60 days of storage were lower than those at Day 1. In conclusion, despite presenting higher lipid oxidation, the samples stored in packages containing 25% CO2 for 90 days at 10°C have lower bacterial counts than vacuum-packed samples. Therefore, further studies should be performed on the packaging of dry-cured meat at adjusted concentrations of CO2.

  20. Status of US storage efforts

    International Nuclear Information System (INIS)

    Leasburg, R.H.

    1984-01-01

    Tasks involved in the implementation of the Nuclear Waste Policy Act are discussed. The need for speedy action on applications to deal with spent fuel storage problems is stressed. The problems faced by the Virginia Electric and Power Company, where full core discharge capability at the 1600-megawatt Surry power station is expected to be reached in early 1986, are reviewed. It is pointed out that although the Nuclear Waste Policy Act does not apply in this case, the problems illustrate the situation that may be faced after the Act is implemented. Problems involved in intro-utility transhipments and dry cask storage of spent fuel from Surry, including transportation ordinances at state and local levels and approval for the use of dry casks for storage, are reported. The suggestion that dry casks be used for interim storage and eventual transport to monitored retrievable storage facilities or permanent storage sites is considered. It is pointed out that data from a proposed 3-utility demonstration program of dry cask storage of consolidated fuels and the storage of fuels in air should give information applicable to the timely implementation of the Nuclear Waste Policy Act

  1. Impact of Harvesting Time and Length of Cold Storage Period On Physiological and Quality Traits of Four Quince Genotypes (Cydonia Oblonga Mill.

    Directory of Open Access Journals (Sweden)

    Tatari Maryam

    2017-06-01

    Full Text Available The investigation was conducted to determine the best harvesting time and the storage period of some quince cultivars and promising genotypes from the collection of quince germplasm in the Horticultural Research Station of Isfahan, Iran. For this study, fruits of ‘Vidoja’ and ‘Isfahan’ cultivars as well as promising genotypes PH2 and NB4 were harvested on 6, 14 and 21 October 2015 and 2016 and then stored at 0 ± 1 °C with 90 ± 5% R.H. for five months. Weight loss, firmness, total soluble solids (TSS, titrable acids (TA, taste index, pectin, total phenols, and percent of decay and surface browning of fruits were measured immediately after harvest and one-month intervals after storage in a factorial experiment based on a completely randomized design with three replications and 10 fruits per each replication. The results showed that ‘Isfahan’ cultivar had the highest TSS (18.83%, total phenols and weight loss. The least weight loss was observed in the ‘Vidoja’ cultivar. NB4 genotype showed the least taste index and pectin, while the most pectin and firmness was related to PH2 genotype. Generally, the delay in harvesting and prolongation of storage led to increasing of TSS and weight loss and declining of firmness and phenols, TA, and pectins. Until the third month of storage, there was no surface browning. Browning symptoms were observed from the fourth month of storage and increased in the fifth month up to 1.72%. Generally, the best harvesting time for ‘Vidoja’ was 185 days and for the rest of the genotypes, it was 193 days after full bloom. Fruit storage for four months in cold is advisable for these cultivars and genotypes.

  2. Shaping of the fungal communities isolated from yellow lupin seeds (Lupinus luteus L. throughout storage time

    Directory of Open Access Journals (Sweden)

    Bożena Cwalina-Ambroziak

    2012-12-01

    Full Text Available The object of the experiment were seeds of two traditional cultivars of yellow lupin (Juno and Amulet cultivated in 1999 in two crop-rotation with 20% and 33% yellow lupine contribution. The quantitative and qualitative composition of the fungal community colonizing the seeds were determined in the laboratory conditions after 0.5-, 1.5- and 2.5-year of storage time. In total 1077 fungal colonies were isolated from the lupin seeds. Fungi representing the species of Penicillium - 29.3%, Alternaria alternata - 26.7% and Rhizopus nigricans - 12.7% were isolated most widely. Among the fungi pathogenic to lupin, the species of Colletotrichum gloeosporioides (16.3% isolates was dominant. The crop rotation with 20% lupin reduced the number of fungal colonies colonizing the seeds including the pathogens from the species of C. gloeosporioides. Seed disinfection decreased the total number of fungal colonies isolated from both cultivars. Higher number of C. gloeosporioides isolates was found in the combination with disinfected seeds. More fungal colonies were obtained from seeds of cv. Amulet than from those of cv. Juno. The storage duration had an effect on the population and the composition of species of fungi isolated from seeds of yellow lupine. With longer storage population of Penicillium spp. and Rhizopus spp. increased, whereas the population of C. gloeosporioides decreased.

  3. Storage, a stake for renewable energies integration

    International Nuclear Information System (INIS)

    Grabette, Olivier

    2013-01-01

    Development of renewable energy sources is challenging the power system operation. Balancing consumption and generation at different times, from real time up to 10 years, with an increasing part of intermittent and fatal sources should indicate a clear route to storage development Up to now on opposite situation occurs. New storage project in Europe has been stopped because of missing business model, and there is no long term economical signal showing it could change in the near future. The capability to predict with a good accuracy, and share through the European transmission system the renewable production places storage in direct competition with other sources of flexibility. However, use case of storage is not limited to energy balancing. Ancillary services, connexion cost optimization, quality of supply are among other possible services offered by storage installation. For all of those, understanding technical requirements and economical issues is an initial condition to open a favourable game area for storage. Exploring new multi-service models through demonstrators, redesigning the electricity market in Europe are key initiatives to approach a new era for storage development. It doesn't prevent innovation to improve performance and reduce cost, an essential condition to give a chance for storage solution compared to other flexibility sources. (author)

  4. Effects of Dry Storage and Resubmersion of Oysters on Total Vibrio vulnificus and Total and Pathogenic (tdh+/trh+) Vibrio parahaemolyticus Levels.

    Science.gov (United States)

    Kinsey, Thomas P; Lydon, Keri A; Bowers, John C; Jones, Jessica L

    2015-08-01

    Vibrio vulnificus (Vv) and Vibrio parahaemolyticus (Vp) are the two leading causes of bacterial illnesses associated with raw shellfish consumption. Levels of these pathogens in oysters can increase during routine antifouling aquaculture practices involving dry storage in ambient air conditions. After storage, common practice is to resubmerge these stored oysters to reduce elevated Vv and Vp levels, but evidence proving the effectiveness of this practice is lacking. This study examined the changes in Vv and in total and pathogenic (thermostable direct hemolysin gene and the tdh-related hemolysin gene, tdh+ and trh+) Vp levels in oysters after 5 or 24 h of dry storage (28 to 32°C), followed by resubmersion (27 to 32°C) for 14 days. For each trial, replicate oyster samples were collected at initial harvest, after dry storage, after 7 days, and after 14 days of resubmersion. Oysters not subjected to dry storage were collected and analyzed to determine natural undisturbed vibrio levels (background control). Vibrio levels were measured using a most-probable-number enrichment followed by real-time PCR. After storage, vibrio levels (excluding tdh+ and trh+ Vp during 5-h storage) increased significantly (P oysters stored for 5 h) were not significantly different (P oysters. Vv and total and pathogenic Vp levels were not significantly different (P > 0.1) from levels in background oysters after 14 days of resubmersion, regardless of dry storage time. These data demonstrate that oyster resubmersion after dry storage at elevated ambient temperatures allows vibrio levels to return to those of background control samples. These results can be used to help minimize the risk of Vv and Vp illnesses and to inform the oyster industry on the effectiveness of routine storing and resubmerging of aquaculture oysters.

  5. Study on elemental analysis of metal and ceramic samples by using laser ablation ion trap mass spectrometry(LAITMS)

    International Nuclear Information System (INIS)

    Cha, Hyung Ki; Park, Hyun Kook; Lee, Sang Chun; SONG, Kyu Seok

    2002-01-01

    Laser ablation ion trap mass spectrometry (LAITMS) was developed for the analysis of metal and ceramic samples. For this study, XeCl excimer laser (308 nm) was used for ablating the samples and ITMS was used as a detector. Samples were introduced from outside of a ring electrode and this way of sample introduction was very effective for solid samples when laser ablation was employed. Helium gas was used as a buffer gas, and its effect on sensitivity and some parameters (buffer gas pressure, ion storage time, and cut-off RF voltage) were studied. The optimized conditions were 1 x 10 - 4 Torr of buffer gas pressure, 100 ms of ion storage time and 1150 V p- p of cut-off RF voltage. From that results, copper (Cu) and molybdenum(Mo) metals were tested with LAITMS and the mass spectra of these pure metals were compared with the natural abundance of isotope ratio. We also examined ceramic samples (Al 2 O 3 , ZrO 2 ) and represented the result of elements analysis

  6. Efficient numerical simulation of heat storage in subsurface georeservoirs

    Science.gov (United States)

    Boockmeyer, A.; Bauer, S.

    2015-12-01

    The transition of the German energy market towards renewable energy sources, e.g. wind or solar power, requires energy storage technologies to compensate for their fluctuating production. Large amounts of energy could be stored in georeservoirs such as porous formations in the subsurface. One possibility here is to store heat with high temperatures of up to 90°C through borehole heat exchangers (BHEs) since more than 80 % of the total energy consumption in German households are used for heating and hot water supply. Within the ANGUS+ project potential environmental impacts of such heat storages are assessed and quantified. Numerical simulations are performed to predict storage capacities, storage cycle times, and induced effects. For simulation of these highly dynamic storage sites, detailed high-resolution models are required. We set up a model that accounts for all components of the BHE and verified it using experimental data. The model ensures accurate simulation results but also leads to large numerical meshes and thus high simulation times. In this work, we therefore present a numerical model for each type of BHE (single U, double U and coaxial) that reduces the number of elements and the simulation time significantly for use in larger scale simulations. The numerical model includes all BHE components and represents the temporal and spatial temperature distribution with an accuracy of less than 2% deviation from the fully discretized model. By changing the BHE geometry and using equivalent parameters, the simulation time is reduced by a factor of ~10 for single U-tube BHEs, ~20 for double U-tube BHEs and ~150 for coaxial BHEs. Results of a sensitivity study that quantify the effects of different design and storage formation parameters on temperature distribution and storage efficiency for heat storage using multiple BHEs are then shown. It is found that storage efficiency strongly depends on the number of BHEs composing the storage site, their distance and

  7. Establishing conditions for the storage and elution of rabies virus RNA using FTA(®) cards.

    Science.gov (United States)

    Sakai, Takeo; Ishii, Ayako; Segawa, Takao; Takagi, Yukihiko; Kobayashi, Yuki; Itou, Takuya

    2015-04-01

    The Flinders Technology Associates filter paper cards (FTA(®) cards) can be used to store nucleic acid from various samples and are easily portable. However, RNA is physicochemically unstable compared with DNA, and appropriate methods have not been established for storage and extraction of RNA from FTA(®) cards. The present study investigated the optimum conditions for storage and elution of viral RNA (vRNA) using rabies virus (RABV) applied to FTA(®) cards. When TE buffer was used, the elution rates of vRNA increased with the length of the elution time. When the cards were stored at -80 °C or -20 °C, vRNA was stable over 3 months. Degradation of vRNAs occurred following storage at 4 °C and room temperature, suggesting that RNA should be extracted from cards as soon as possible if no freezer is available. When we tried to amplify vRNA from RABV-infected animal brains applied to FTA(®) cards and stored at -80 °C for 6 months, we did not detect any amplified products with the primer set for 964 bp of RABV N gene. However, we were able to detect amplified products by increasing the elution time of vRNA from FTA(®) cards from 30 min to 24 hr or by changing the primer sets to amplify 290 bp of N gene. Thus, we recommend extending the elution time for damaged or low concentration samples in FTA(®) cards.

  8. Penicillin improves the milt quality of Persian sturgeon, Acipenser persicus during short-term storage

    Directory of Open Access Journals (Sweden)

    Mostafa Halimi

    2014-04-01

    Full Text Available This study was conducted to examine the effects of antibiotic (5000 units of penicillin on sperm quality of Persian sturgeon, Acipenser persicus during 9 days in vitro storage of milt. For this purpose, the milt samples were stored in the presence and absence of 5000 units of penicillin. Freshwater was used as sperm activator. The milt samples were stored at 4°C and the motility indices were measured 0, 3, 6 and 9 days after storage. The sperm duration and percentage of sperm motility decreased after 6 days of storage both in the presence and absence of antibiotic, although this decrease was more significant in the absence of antibiotic. After 9 days of storage, the lowest values of sperm motility indices was recorded for antibiotic receiving milt samples while no motile spermatozoa observed for antibiotic-free milt samples. In conclusion, our results demonstrated that 5000 units of penicillin improve the Persian sturgeon milt quality during short-term storage.

  9. Effect of irradiation, active and modified atmosphere packaging, container oxygen barrier and storage conditions on the physicochemical and sensory properties of raw unpeeled almond kernels (Prunus dulcis).

    Science.gov (United States)

    Mexis, Stamatios F; Riganakos, Kyriakos A; Kontominas, Michael G

    2011-03-15

    The present study investigated the effect of irradiation, active and modified atmosphere packaging, and storage conditions on quality retention of raw, whole, unpeeled almonds. Almond kernels were packaged in barrier and high-barrier pouches, under N(2) or with an O(2) absorber and stored either under fluorescent lighting or in the dark at 20 °C for 12 months. Quality parameters monitored were peroxide value, hexanal content, colour, fatty acid composition and volatile compounds. Of the sensory attributes colour, texture, odour and taste were evaluated. Peroxide value and hexanal increased with dose of irradiation and storage time. Irradiation resulted in a decrease of polyunsaturated and monounsaturated fatty acids during storage with a parallel increase of saturated fatty acids. Volatile compounds were not affected by irradiation but increased with storage time indicating enhanced lipid oxidation. Colour parameters of samples remained unaffected immediately after irradiation. For samples packaged under a N(2) , atmosphere L and b values decreased during storage with a parallel increase of value a resulting to gradual product darkening especially in irradiated samples. Non-irradiated almonds retained acceptable quality for ca. 12 months stored at 20 °C with the O(2) absorber irrespective of lighting conditions and packaging material oxygen barrier. The respective shelf life for samples irradiated at 1.0 kGy was 12 months packaged in PET-SiOx//LDPE irrespective of lighting conditions and 12 months for samples irradiated at 3 kGy packaged in PET-SiOx//LDPE stored in the dark. Copyright © 2010 Society of Chemical Industry.

  10. CHANGES IN THE QUALITY OF DRESSED CHICKEN OBTAINED FROM DIFFERENT SOURCES DURING FROZEN STORAGE

    Directory of Open Access Journals (Sweden)

    Santosh Kumar HT

    2014-06-01

    Full Text Available This present study examines the preservation quality of dressed chicken procured from different sources of processing during storage at –18±1ºC. Breast portion of the dressed birds obtained from three different sources, viz. market/road side slaughtered chicken (MSC, retail slaughtered chicken (RSC, and scientifically slaughtered chicken (SSC, were cut into chunks, divided into 250 g portions, packed in polyethylene bags, stored at –18±1ºC and evaluated at 30 days intervals for changes in quality attributes. Frozen storage had no marked influence on pH change of the samples. SSC samples had higher extract release volume (15.34±0.08 to 13.45±0.93 ml than MSC (13.00±0.19 to 9.91±0.97 ml and RSC samples (13.65±0.24 to 11.70±1.21ml. There was significant increase (P<0.05 in thiobarbituric acid of all three sample types during storage but values were well below the threshold level of spoilage. SSC samples showed lower tyrosine content throughout frozen storage compared to MSC and RSC samples. A significant decline in microbial load, viz. total viable count, coliform count, psychrophilic count and yeast and moulds count were noticed during frozen storage. Organoleptic attributes, viz. appearance, flavour, texture and overall palatability were not affected due to frozen storage except juiciness in MSC samples which decreased (P<0.05 from 6.53±0.13 to 5.96±0.11 on 90 days of storage. Although the scientifically slaughtered chicken had better quality, all the sample types could be stored at –18±1ºC till 90 days without much deterioration in their quality.

  11. Application of a Surimi-Based Coating to Improve the Quality Attributes of Shrimp during Refrigerated Storage.

    Science.gov (United States)

    Sharaf Eddin, Abdulhakim; Tahergorabi, Reza

    2017-09-05

    Shrimp is a popular seafood throughout the world. However, shrimp is highly perishable due to biochemical, microbiological, or physical changes during postmortem storage. In this study, the effect of a surimi-based coating with and without montmorillonite (MMT) nanoclay on shrimp quality was evaluated during eight days of refrigerator storage. Use of a surimi-based coating resulted in reductions of aerobic plate counts (APC) up to 2 log units. The combined effect of the MMT and coating was observed. Surimi-based coating with MMT resulted in lower APC ( p coating with MMT to the shrimp samples improved sensory quality and delayed lipid oxidation and color deterioration during storage time. In general, better texture was observed when coating was applied either with or without MMT. This study suggests that surimi-based coating may improve the quality of shrimp during refrigerated storage.

  12. Energy storage

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This chapter discusses the role that energy storage may have on the energy future of the US. The topics discussed in the chapter include historical aspects of energy storage, thermal energy storage including sensible heat storage, latent heat storage, thermochemical heat storage, and seasonal heat storage, electricity storage including batteries, pumped hydroelectric storage, compressed air energy storage, and superconducting magnetic energy storage, and production and combustion of hydrogen as an energy storage option

  13. Simulation of Porous Medium Hydrogen Storage - Estimation of Storage Capacity and Deliverability for a North German anticlinal Structure

    Science.gov (United States)

    Wang, B.; Bauer, S.; Pfeiffer, W. T.

    2015-12-01

    Large scale energy storage will be required to mitigate offsets between electric energy demand and the fluctuating electric energy production from renewable sources like wind farms, if renewables dominate energy supply. Porous formations in the subsurface could provide the large storage capacities required if chemical energy carriers such as hydrogen gas produced during phases of energy surplus are stored. This work assesses the behavior of a porous media hydrogen storage operation through numerical scenario simulation of a synthetic, heterogeneous sandstone formation formed by an anticlinal structure. The structural model is parameterized using data available for the North German Basin as well as data given for formations with similar characteristics. Based on the geological setting at the storage site a total of 15 facies distributions is generated and the hydrological parameters are assigned accordingly. Hydraulic parameters are spatially distributed according to the facies present and include permeability, porosity relative permeability and capillary pressure. The storage is designed to supply energy in times of deficiency on the order of seven days, which represents the typical time span of weather conditions with no wind. It is found that using five injection/extraction wells 21.3 mio sm³ of hydrogen gas can be stored and retrieved to supply 62,688 MWh of energy within 7 days. This requires a ratio of working to cushion gas of 0.59. The retrievable energy within this time represents the demand of about 450000 people. Furthermore it is found that for longer storage times, larger gas volumes have to be used, for higher delivery rates additionally the number of wells has to be increased. The formation investigated here thus seems to offer sufficient capacity and deliverability to be used for a large scale hydrogen gas storage operation.

  14. Quality and sensory characteristics of hard red wheat after residential storage for up to 32 y.

    Science.gov (United States)

    Rose, Devin J; Ogden, Lynn V; Dunn, Michael L; Jamison, Rachel G; Lloyd, Michelle A; Pike, Oscar A

    2011-01-01

    Samples of hard red wheat packaged for long-term storage, ranging in age from 0 to 32 y, were obtained from donors in residential households. All samples had been stored under nonabusive conditions (7% to 10% moisture, 13 to 27 °C). Selected quality parameters of the wheat (moisture, thiamin, free fatty acids, flour extraction rate, bread loaf volume, and bread firmness) and sensory properties of bread made from the stored wheat (aroma, appearance, texture, flavor, overall liking, acceptance for use as part of the regular diet, and acceptance for use in emergency situations) were evaluated. Free fatty acids increased significantly from 0.897 to 11.8 μmol/g, and flour extraction rate decreased significantly from 76.5% to 69.9% over time. None of the other quality parameters measured (moisture, thiamin, bread loaf volume, and bread firmness) were significantly correlated with wheat storage time. Panelists who frequently or occasionally consume whole wheat bread rated all breads made from the stored wheat with hedonic scores (9-point scale) of at least 6.4 (like slightly to moderately). Consumer ratings of bread texture, flavor, and overall acceptability were negatively correlated with storage time (P baking quality. Therefore, we tested wheat that had been stored under residential conditions for up to 32 y to determine its functional quality and consumer acceptability. Our results indicate that wheat of low moisture (7% to 10%) packaged in sealed cans and stored for up to 32 y at or below typical room temperature retains quality and can be made into bread that is well accepted by consumers. Thus, whole wheat has good long-term storage stability and can be recommended for emergency food supplies.

  15. Influence of Different Light Sources, Illumination Intensities and Storage Times on the Vitamin C Content in Pasteurized Milk

    OpenAIRE

    ÇAKMAKÇI, Songül; TURGUT, Tamer

    2005-01-01

    The effect of various light sources and illumination intensities on the destruction of vitamin C was determined during the storage of pasteurized milk. For this purpose, raw cow's milk was pasteurized at 72 oC for 15 s, and then stored in 2 different refrigerators (4 ± 1oC) illuminated by fluorescent and tungsten light (normal light) sources with intensities of 1100, 2400 and 5800 lux. As a control group, a pasteurized milk sample was stored at the same temperature under dark conditi...

  16. Characteristic mega-basin water storage behavior using GRACE.

    Science.gov (United States)

    Reager, J T; Famiglietti, James S

    2013-06-01

    [1] A long-standing challenge for hydrologists has been a lack of observational data on global-scale basin hydrological behavior. With observations from NASA's Gravity Recovery and Climate Experiment (GRACE) mission, hydrologists are now able to study terrestrial water storage for large river basins (>200,000 km 2 ), with monthly time resolution. Here we provide results of a time series model of basin-averaged GRACE terrestrial water storage anomaly and Global Precipitation Climatology Project precipitation for the world's largest basins. We address the short (10 year) length of the GRACE record by adopting a parametric spectral method to calculate frequency-domain transfer functions of storage response to precipitation forcing and then generalize these transfer functions based on large-scale basin characteristics, such as percent forest cover and basin temperature. Among the parameters tested, results show that temperature, soil water-holding capacity, and percent forest cover are important controls on relative storage variability, while basin area and mean terrain slope are less important. The derived empirical relationships were accurate (0.54 ≤  E f  ≤ 0.84) in modeling global-scale water storage anomaly time series for the study basins using only precipitation, average basin temperature, and two land-surface variables, offering the potential for synthesis of basin storage time series beyond the GRACE observational period. Such an approach could be applied toward gap filling between current and future GRACE missions and for predicting basin storage given predictions of future precipitation.

  17. Photovoltaic power systems energy storage

    International Nuclear Information System (INIS)

    Buldini, P.L.

    1991-01-01

    Basically, the solar photovoltaic power system consists of: Array of solar panels; Charge/voltage stabilizer; Blocking diode and Storage device. The storage device is a very important part of the system due to the necessity to harmonize the inevitable time shift between energy supply and demand. As energy storage, different devices can be utilized, such as hydropumping, air or other gas compression, flywheel, superconducting magnet, hydrogen generation and so on, but actually secondary (rechargeable) electrochemical cells appear to be the best storage device, due to the direct use for recharge of the d.c. current provided by the solar panels, without any intermediate step of energy transformation and its consequent loss of efficiency

  18. physico-chemical changes in UHT treated and whole milk powder during storage at ambient temperature

    International Nuclear Information System (INIS)

    Akhtar, S.; Zahoor, T.; Hashmi, A.M.

    2003-01-01

    We studied the changes in pH, acidity and viscosity of ultra high temperature (UHT) treated and reconstituted whole milk powder (WMP) during storage of 90 days at room temperature. The samples were analyzed at 0,30,60 and 90 days intervals for these physico-chemical properties of the milk types. Values indicated an increase in acidity and viscosity with a decrease in pH with the storage time increased both in UHT treated and reconstituted whole milk powder. Apart from many enzymatic changes to deteriorate the milk, these apparent changes in milk characteristics may be one of the reasons that UHT milk cannot be kept unspoiled above 90 days and the quality of WMP is influenced within this time period. (author)

  19. Comparison of correlation analysis techniques for irregularly sampled time series

    Directory of Open Access Journals (Sweden)

    K. Rehfeld

    2011-06-01

    Full Text Available Geoscientific measurements often provide time series with irregular time sampling, requiring either data reconstruction (interpolation or sophisticated methods to handle irregular sampling. We compare the linear interpolation technique and different approaches for analyzing the correlation functions and persistence of irregularly sampled time series, as Lomb-Scargle Fourier transformation and kernel-based methods. In a thorough benchmark test we investigate the performance of these techniques.

    All methods have comparable root mean square errors (RMSEs for low skewness of the inter-observation time distribution. For high skewness, very irregular data, interpolation bias and RMSE increase strongly. We find a 40 % lower RMSE for the lag-1 autocorrelation function (ACF for the Gaussian kernel method vs. the linear interpolation scheme,in the analysis of highly irregular time series. For the cross correlation function (CCF the RMSE is then lower by 60 %. The application of the Lomb-Scargle technique gave results comparable to the kernel methods for the univariate, but poorer results in the bivariate case. Especially the high-frequency components of the signal, where classical methods show a strong bias in ACF and CCF magnitude, are preserved when using the kernel methods.

    We illustrate the performances of interpolation vs. Gaussian kernel method by applying both to paleo-data from four locations, reflecting late Holocene Asian monsoon variability as derived from speleothem δ18O measurements. Cross correlation results are similar for both methods, which we attribute to the long time scales of the common variability. The persistence time (memory is strongly overestimated when using the standard, interpolation-based, approach. Hence, the Gaussian kernel is a reliable and more robust estimator with significant advantages compared to other techniques and suitable for large scale application to paleo-data.

  20. Neuroimaging of Lipid Storage Disorders

    Science.gov (United States)

    Rieger, Deborah; Auerbach, Sarah; Robinson, Paul; Gropman, Andrea

    2013-01-01

    Lipid storage diseases, also known as the lipidoses, are a group of inherited metabolic disorders in which there is lipid accumulation in various cell types, including the central nervous system, because of the deficiency of a variety of enzymes. Over time, excessive storage can cause permanent cellular and tissue damage. The brain is particularly…