WorldWideScience

Sample records for sample radiofrequency identification

  1. Predicting nurses' acceptance of radiofrequency identification technology.

    Science.gov (United States)

    Norten, Adam

    2012-10-01

    The technology of radiofrequency identification allows for the scanning of radiofrequency identification-tagged objects and individuals without line-of-sight requirements. Healthcare organizations use radiofrequency identification to ensure the health and safety of patients and medical personnel and to uncover inefficiencies. Although the successful implementation of a system incorporating radiofrequency identification technologies requires acceptance and use of the technology, some nurses using radiofrequency identification in hospitals feel like "Big Brother" is watching them. This predictive study used a theoretical model assessing the effect of five independent variables: privacy concerns, attitudes, subjective norms, controllability, and self-efficacy, on a dependent variable, nurses' behavioral intention to use radiofrequency identification. A Web-based questionnaire containing previously validated questions was answered by 106 US RNs. Multiple linear regression showed that all constructs together accounted for 60% of the variance in nurses' intention to use radiofrequency identification. Of the predictors in the model, attitudes provided the largest unique contribution when the other predictors in the model were held constant; subjective norms also provided a unique contribution. Privacy concerns, controllability, and self-efficacy did not provide a significant contribution to nurses' behavioral intention to use radiofrequency identification.

  2. 21 CFR 880.6300 - Implantable radiofrequency transponder system for patient identification and health information.

    Science.gov (United States)

    2010-04-01

    ... patient identification and health information. 880.6300 Section 880.6300 Food and Drugs FOOD AND DRUG... radiofrequency transponder system for patient identification and health information. (a) Identification. An implantable radiofrequency transponder system for patient identification and health information is a device...

  3. A prospective clinical study to evaluate the safety and performance of wireless localization of nonpalpable breast lesions using radiofrequency identification technology.

    Science.gov (United States)

    Dauphine, Christine; Reicher, Joshua J; Reicher, Murray A; Gondusky, Christina; Khalkhali, Iraj; Kim, Michelle

    2015-06-01

    The purpose of this study was to evaluate the safety and performance of localizing nonpalpable breast lesions using radiofrequency identification technology. Twenty consecutive women requiring preoperative localization of a breast lesion were recruited. Subjects underwent placement of both a hook wire and a radiofrequency identification tag immediately before surgery. The radiofrequency identification tag was the primary method used by the operating surgeon to localize each lesion during excision, with the hook wire serving as backup in case of tag migration or failed localization. Successful localization with removal of the intended lesion was the primary outcome measured. Tag migration and postoperative infection were also noted to assess safety. Twenty patients underwent placement of a radiofrequency identification tag, 12 under ultrasound guidance and eight with stereotactic guidance. In all cases, the radiofrequency identification tag was successfully localized by the reader at the level of the skin before incision, and the intended lesion was removed along with the radiofrequency identification tag. There were no localization failures and no postoperative infections. Tag migration did not occur before incision, but in three cases, occurred as the lesion was being retracted with fingers to make the final cut along the deep surface of the specimen. In this initial clinical study, radiofrequency tags were safe and able to successfully localize nonpalpable breast lesions. Radiofrequency identification technology may represent an alternative method to hook wire localization.

  4. Effects of radiation from a radiofrequency identification (RFID) microchip on human cancer cells.

    Science.gov (United States)

    Lai, Henry C; Chan, Ho Wing; Singh, Narendra P

    2016-01-01

    Radiofrequency identification (RFID) microchips are used to remotely identify objects, e.g. an animal in which a chip is implanted. A passive RFID microchip absorbs energy from an external source and emits a radiofrequency identification signal which is then decoded by a detector. In the present study, we investigated the effect of the radiofrequency energy emitted by a RFID microchip on human cancer cells. Molt-4 leukemia, BT474 breast cancer, and HepG2 hepatic cancer cells were exposed in vitro to RFID microchip-emitted radiofrequency field for 1 h. Cells were counted before and after exposure. Effects of pretreatment with the spin-trap compound N-tert-butyl-alpha-phenylnitrone or the iron-chelator deferoxamine were also investigated. Results We found that the energy effectively killed/retarded the growth of the three different types of cancer cells, and the effect was blocked by the spin-trap compound or the iron-chelator, whereas an inactive microchip and energy from the external source had no significant effect on the cells. Conclusions Data of the present study suggest that radiofrequency field from the microchip affects cancer cells via the Fenton Reaction. Implantation of RFID microchips in tumors may provide a new method for cancer treatment.

  5. Radiofrequency identification: exploiting an old technology for measuring nurse time and motion.

    Science.gov (United States)

    Jones, Terry L

    2012-09-01

    A national campaign is underway to increase the amount of time staff nurses spend at the bedside of hospitalized patients through redesign of the work environment. This kind of work redesign requires robust data depicting what nurses do and how they spend their time. Historically, these kinds of data have been difficult, costly, and time consuming to collect. Wireless capture of data on the movement of humans within the work environment (ie, time and motion) is now possible through radiofrequency identification technology. When small tracking devices the size of a quarter are affixed to their clothing, the movement of nurses throughout a patient care unit can be monitored. The duration and frequency of patient interaction are captured along with the duration of time spent in other locations of interest to include nurses' station, supply room, medication room, doctors' station, electronic documentation stations, family waiting rooms, and the hallway. Patterns of nurse movement and time allocation can be efficiently identified, and the effects of staffing practices, workflows, and unit layout evaluated. Integration of radiofrequency identification time and motion data with other databases enables nurse leaders to link nursing time to important cost and quality outcomes. Nurse leaders should explore the usefulness of radiofrequency identification technology in addressing data needs for nurse time and motion.

  6. The emergence of radiofrequency identification tags: applications in surgery.

    Science.gov (United States)

    Schwaitzberg, S D

    2006-08-01

    Radiofrequency identification (RFID) is a wireless method of automatic identification. Currently, RFID tags are emerging into our environment in many aspects of our lives. Applications are being developed in a variety of fields, including health care. Aspects of surgical care will lend themselves to this approach. This technology could provide large amounts of data that not only carry the promise of improving health care, but also may have an impact on personal aspects of our daily lives. Each of us must become familiar with the risks and benefits of RFID use.

  7. Development of the method of aggregation to determine the current storage area using computer vision and radiofrequency identification

    Science.gov (United States)

    Astafiev, A.; Orlov, A.; Privezencev, D.

    2018-01-01

    The article is devoted to the development of technology and software for the construction of positioning and control systems in industrial plants based on aggregation to determine the current storage area using computer vision and radiofrequency identification. It describes the developed of the project of hardware for industrial products positioning system in the territory of a plant on the basis of radio-frequency grid. It describes the development of the project of hardware for industrial products positioning system in the plant on the basis of computer vision methods. It describes the development of the method of aggregation to determine the current storage area using computer vision and radiofrequency identification. Experimental studies in laboratory and production conditions have been conducted and described in the article.

  8. Ethical implications of implantable radiofrequency identification (RFID) tags in humans.

    Science.gov (United States)

    Foster, Kenneth R; Jaeger, Jan

    2008-08-01

    This article reviews the use of implantable radiofrequency identification (RFID) tags in humans, focusing on the VeriChip (VeriChip Corporation, Delray Beach, FL) and the associated VeriMed patient identification system. In addition, various nonmedical applications for implanted RFID tags in humans have been proposed. The technology offers important health and nonhealth benefits, but raises ethical concerns, including privacy and the potential for coercive implantation of RFID tags in individuals. A national discussion is needed to identify the limits of acceptable use of implantable RFID tags in humans before their use becomes widespread and it becomes too late to prevent misuse of this useful but ethically problematic technology.

  9. 21 CFR 882.4725 - Radiofrequency lesion probe.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency lesion probe. 882.4725 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4725 Radiofrequency lesion probe. (a) Identification. A radiofrequency lesion probe is a device connected to a radiofrequency (RF...

  10. Adoption of radio-frequency identification to establish traceability in Taiwanese eel exported to the Japanese market.

    Science.gov (United States)

    Jeng, Shu-Ching; Wu, Chun-Lung; Yang, I-Da

    2013-01-01

    Eel culture and export to the Japanese market is an important industry in Taiwan; however, the average amount produced by each farm is small. Eels from different farms might be mixed before export, making it difficult to determine which farm is responsible for eels containing drug residues. Therefore, the Taiwanese government uses a two-stage procedure of inspection and accreditation for validating the use of good practice in aquaculture farming. Nevertheless, it is still difficult to trace any farm that has produced eels containing drug residues. Radio-frequency identification has the potential to establish traceability in eel products. Here we suggest that Japanese eel importers should insist on the use of radio-frequency identification by Taiwanese eel exporters to enable verification of the safety of eel products being exported to the Japanese market.

  11. 21 CFR 882.4400 - Radiofrequency lesion generator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency lesion generator. 882.4400 Section... (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4400 Radiofrequency lesion generator. (a) Identification. A radiofrequency lesion generator is a device used to produce...

  12. Radiofrequency identification for inventory in neurointerventional practice.

    Science.gov (United States)

    Byers, Ernest; Gomez, Max A; Sheridan, Robert M; Orr, Nelson W; Hirsch, Joshua A

    2011-03-01

    Implementations of radiofrequency identification (RFID) systems within hospital settings are not unique or without controversy. To date, little consideration has been given to use of this technology in clinical interventional radiologic practice. The potential financial advantages coupled with benefits to quality and safety and increases in staff satisfaction are considerable. The authors outline these advantages by enabling readers to broadly consider the systemic perspective of implementing RFID technology with an associated vision toward downstream growth. Furthermore, the authors demonstrate the benefits of RFID technology integration in reducing cost and increasing quality assurance and the on-time delivery of services. Implementing RFID requires commitment from frontline technologist staff members to work collaboratively with management and external vendors. Ultimately, the authors believe this technology can positively influence patient care. Copyright © 2011 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. 21 CFR 886.4100 - Radiofrequency electrosurgical cautery apparatus.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency electrosurgical cautery apparatus... SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4100 Radiofrequency electrosurgical cautery apparatus. (a) Identification. A radiofrequency electrosurgical cautery apparatus is an AC...

  14. What are the benefits and risks of fitting patients with radiofrequency identification devices.

    Science.gov (United States)

    Levine, Mark; Adida, Ben; Mandl, Kenneth; Kohane, Isaac; Halamka, John

    2007-11-27

    In 2004, the United States Food and Drug Administration approved a radiofrequency identification (RFID) device that is implanted under the skin of the upper arm of patients and that stores the patient's medical identifier. When a scanner is passed over the device, the identifier is displayed on the screen of an RFID reader. An authorized health professional can then use the identifier to access the patient's clinical information, which is stored in a separate, secure database. Such RFID devices may have many medical benefits--such as expediting identification of patients and retrieval of their medical records. But critics of the technology have raised several concerns, including the risk of the patient's identifying information being used for nonmedical purposes.

  15. 21 CFR 870.2910 - Radiofrequency physiological signal transmitter and receiver.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency physiological signal transmitter... Devices § 870.2910 Radiofrequency physiological signal transmitter and receiver. (a) Identification. A radiofrequency physiological signal transmitter and receiver is a device used to condition a physiological signal...

  16. Precise turnaround time measurement of laboratory processes using radiofrequency identification technology.

    Science.gov (United States)

    Mayer, Horst; Brümmer, Jens; Brinkmann, Thomas

    2011-01-01

    To implement Lean Six Sigma in our central laboratory we conducted a project to measure single pre-analytical steps influencing turnaround time (TAT) of emergency department (ED) serum samples. The traditional approach of extracting data from the Laboratory Information System (LIS) for a retrospective calculation of a mean TAT is not suitable. Therefore, we used radiofrequency identification (RFID) chips for real time tracking of individual samples at any pre-analytical step. 1,200 serum tubes were labelled with RFID chips and were provided to the emergency department. 3 RFID receivers were installed in the laboratory: at the outlet of the pneumatic tube system, at the centrifuge, and in the analyser area. In addition, time stamps of sample entry at the automated sample distributor and communication of results from the analyser were collected from LIS. 1,023 labelled serum tubes arrived at our laboratory. 899 RFID tags were used for TAT calculation. The following transfer times were determined (median 95th percentile in min:sec): pneumatic tube system --> centrifuge (01:25/04:48), centrifuge --> sample distributor (14:06/5:33), sample distributor --> analysis system zone (02:39/15:07), analysis system zone --> result communication (12:42/22:21). Total TAT was calculated at 33:19/57:40 min:sec. Manual processes around centrifugation were identified as a major part of TAT with 44%/60% (median/95th percentile). RFID is a robust, easy to use, and error-free technology and not susceptible to interferences in the laboratory environment. With this study design we were able to measure significant variations in a single manual sample transfer process. We showed that TAT is mainly influenced by manual steps around the centrifugation process and we concluded that centrifugation should be integrated in solutions for total laboratory automation.

  17. What are the benefits and risks of fitting patients with radiofrequency identification devices.

    Directory of Open Access Journals (Sweden)

    Mark Levine

    2007-11-01

    Full Text Available In 2004, the United States Food and Drug Administration approved a radiofrequency identification (RFID device that is implanted under the skin of the upper arm of patients and that stores the patient's medical identifier. When a scanner is passed over the device, the identifier is displayed on the screen of an RFID reader. An authorized health professional can then use the identifier to access the patient's clinical information, which is stored in a separate, secure database. Such RFID devices may have many medical benefits--such as expediting identification of patients and retrieval of their medical records. But critics of the technology have raised several concerns, including the risk of the patient's identifying information being used for nonmedical purposes.

  18. Radiofrequency Identification by using Drones in Railway Accidents and Disaster Situations

    Directory of Open Access Journals (Sweden)

    Géza Károly Kiss Leizer

    2017-06-01

    Full Text Available Today, railway operation procedures include the transportation of large amount of hazardous substances. Our research has been motivated by the desire to find concrete and urgent solutions to the safety issues of handling waste generated manly in case of accidents and disaster situations during the transportation of hazardous substances In order to ensure safety in the transportation of dangerous goods, and to facilitate the fast and efficient waste handling of hazardous substances released into the environment during unexpected events, we have elaborated a new method, in which we suggest the radiofrequency identification of dangerous consignments in case of disaster situations by the use of drones.

  19. A Novel L-Shape Ultra Wideband Chipless Radio-Frequency Identification Tag

    Directory of Open Access Journals (Sweden)

    Khaled Issa

    2017-01-01

    Full Text Available A novel compact dual-polarized-spectral-signature-based chipless radio-frequency identification (RFID tag is presented. Specifically, an L-shape resonator-based structure is optimized to have different spectral signatures in both horizontal and vertical polarizations, in order to double the encoding capacity. Resonators’ slot width and the space between closely placed resonators are also optimized to enhance the mutual coupling, thereby helping in achieving high-data encoding density. The proposed RFID tag operates over 5 GHz to 10 GHz frequency band. As a proof of concept, three different 18-bit dual-polarized RFID tags are simulated, fabricated, and tested in an anechoic chamber environment. The measurement data show reasonable agreement with the simulation results, with respect to resonators’ frequency positions, null depth, and their bandwidth over the operational spectrum.

  20. Implanting inequality: empirical evidence of social and ethical risks of implantable radio-frequency identification (RFID) devices.

    Science.gov (United States)

    Monahan, Torin; Fisher, Jill A

    2010-10-01

    The aim of this study was to assess empirically the social and ethical risks associated with implantable radio-frequency identification (RFID) devices. Qualitative research included observational studies in twenty-three U.S. hospitals that have implemented new patient identification systems and eighty semi-structured interviews about the social and ethical implications of new patient identification systems, including RFID implants. The study identified three primary social and ethical risks associated with RFID implants: (i) unfair prioritization of patients based on their participation in the system, (ii) diminished trust of patients by care providers, and (iii) endangerment of patients who misunderstand the capabilities of the systems. RFID implants may aggravate inequalities in access to care without any clear health benefits. This research underscores the importance of critically evaluating new healthcare technologies from the perspective of both normative ethics and empirical ethics.

  1. Compact printed two dipole array antenna with a high front-back ratio for ultra-high-frequency radio-frequency identification handheld reader applications

    DEFF Research Database (Denmark)

    Liu, Qi; Zhang, Shuai; He, Sailing

    2015-01-01

    A printed two-dipole array antenna with a high front-back ratio is proposed for ultra-high-frequency (UHF) radio-frequency identification handheld readers. The proposed antenna is a parasitic dual-element array with the ends of both elements folded back towards each other for additional coupling....

  2. Applications for radio-frequency identification technology in the perioperative setting.

    Science.gov (United States)

    Zhao, Tiyu; Zhang, Xiaoxiang; Zeng, Lili; Xia, Shuyan; Hinton, Antentor Othrell; Li, Xiuyun

    2014-06-01

    We implemented a two-year project to develop a security-gated management system for the perioperative setting using radio-frequency identification (RFID) technology to enhance the management efficiency of the OR. We installed RFID readers beside the entrances to the OR and changing areas to receive and process signals from the RFID tags that we sewed into surgical scrub attire and shoes. The system also required integrating automatic access control panels, computerized lockers, light-emitting diode (LED) information screens, wireless networks, and an information system. By doing this, we are able to control the flow of personnel and materials more effectively, reduce OR costs, optimize the registration and attire-changing process for personnel, and improve management efficiency. We also anticipate this system will improve patient safety by reducing the risk of surgical site infection. Application of security-gated management systems is an important and effective way to help ensure a clean, convenient, and safe management process to manage costs in the perioperative area and promote patient safety. Copyright © 2014 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  3. Radiofrequency Neurotomy

    Science.gov (United States)

    ... your specific symptoms. What you can expect Before radiofrequency neurotomy Let your doctor know if you take ... tobacco products the day of your procedure. During radiofrequency neurotomy Radiofrequency neurotomy is an outpatient procedure, so ...

  4. Surface Characterization of Nb Samples Electro-polished Together With Real Superconducting Radio-frequency Accelerator Cavities

    International Nuclear Information System (INIS)

    Zhao, Xin; Geng, Rong-Li; Tyagi, P.V.; Hayano, Hitoshi; Kato, Shigeki; Nishiwaki, Michiru; Saeki, Takayuki; Sawabe, Motoaki

    2010-01-01

    We report the results of surface characterizations of niobium (Nb) samples electropolished together with a single cell superconducting radio-frequency accelerator cavity. These witness samples were located in three regions of the cavity, namely at the equator, the iris and the beam-pipe. Auger electron spectroscopy (AES) was utilized to probe the chemical composition of the topmost four atomic layers. Scanning electron microscopy with energy dispersive X-ray for elemental analysis (SEM/EDX) was used to observe the surface topography and chemical composition at the micrometer scale. A few atomic layers of sulfur (S) were found covering the samples non-uniformly. Niobium oxide granules with a sharp geometry were observed on every sample. Some Nb-O granules appeared to also contain sulfur.

  5. Calorimeters for Precision Power Dissipation Measurements on Controlled-Temperature Superconducting Radiofrequency Samples

    International Nuclear Information System (INIS)

    Xiao, Binping P.; Kelley, Michael J.; Reece, Charles E.; Phillips, H. L.

    2012-01-01

    Two calorimeters, with stainless steel and Cu as the thermal path material for high precision and high power versions, respectively, have been designed and commissioned for the surface impedance characterization (SIC) system at Jefferson Lab to provide low temperature control and measurement for CW power up to 22 W on a 5 cm dia. disk sample which is thermally isolated from the RF portion of the system. A power compensation method has been developed to measure the RF induced power on the sample. Simulation and experimental results show that with these two calorimeters, the whole thermal range of interest for superconducting radiofrequency (SRF) materials has been covered. The power measurement error in the interested power range is within 1.2% and 2.7% for the high precision and high power versions, respectively. Temperature distributions on the sample surface for both versions have been simulated and the accuracy of sample temperature measurements have been analysed. Both versions have the ability to accept bulk superconductors and thin film superconducting samples with a variety of substrate materials such as Al, Al 2 O 3 , Cu, MgO, Nb and Si

  6. Assessment of outdoor radiofrequency electromagnetic field exposure through hotspot localization using kriging-based sequential sampling.

    Science.gov (United States)

    Aerts, Sam; Deschrijver, Dirk; Verloock, Leen; Dhaene, Tom; Martens, Luc; Joseph, Wout

    2013-10-01

    In this study, a novel methodology is proposed to create heat maps that accurately pinpoint the outdoor locations with elevated exposure to radiofrequency electromagnetic fields (RF-EMF) in an extensive urban region (or, hotspots), and that would allow local authorities and epidemiologists to efficiently assess the locations and spectral composition of these hotspots, while at the same time developing a global picture of the exposure in the area. Moreover, no prior knowledge about the presence of radiofrequency radiation sources (e.g., base station parameters) is required. After building a surrogate model from the available data using kriging, the proposed method makes use of an iterative sampling strategy that selects new measurement locations at spots which are deemed to contain the most valuable information-inside hotspots or in search of them-based on the prediction uncertainty of the model. The method was tested and validated in an urban subarea of Ghent, Belgium with a size of approximately 1 km2. In total, 600 input and 50 validation measurements were performed using a broadband probe. Five hotspots were discovered and assessed, with maximum total electric-field strengths ranging from 1.3 to 3.1 V/m, satisfying the reference levels issued by the International Commission on Non-Ionizing Radiation Protection for exposure of the general public to RF-EMF. Spectrum analyzer measurements in these hotspots revealed five radiofrequency signals with a relevant contribution to the exposure. The radiofrequency radiation emitted by 900 MHz Global System for Mobile Communications (GSM) base stations was always dominant, with contributions ranging from 45% to 100%. Finally, validation of the subsequent surrogate models shows high prediction accuracy, with the final model featuring an average relative error of less than 2dB (factor 1.26 in electric-field strength), a correlation coefficient of 0.7, and a specificity of 0.96. Copyright © 2013 Elsevier Inc. All rights

  7. Graphene screen-printed radio-frequency identification devices on flexible substrates

    NARCIS (Netherlands)

    Arapov, K.; Jaakkola, K.; Ermolov, V.; Bex, G.; Rubingh, E.; Haque, S.; Sandberg, H.; Abbel, R.; de With, G.; Friedrich, H.

    2016-01-01

    Despite the great promise of printed flexible electronics from 2D crystals, and especially graphene, few scalable applications have been reported so far that can be termed roll-to-roll compatible. Here we combine screen printed graphene with photonic annealing to realize radio-frequency

  8. Using a Radiofrequency Identification System for Improving the Patient Discharge Process: A Simulation Study.

    Science.gov (United States)

    Shim, Sung J; Kumar, Arun; Jiao, Roger

    2016-01-01

    A hospital is considering deploying a radiofrequency identification (RFID) system and setting up a new "discharge lounge" to improve the patient discharge process. This study uses computer simulation to model and compare the current process and the new process, and it assesses the impact of the RFID system and the discharge lounge on the process in terms of resource utilization and time taken in the process. The simulation results regarding resource utilization suggest that the RFID system can slightly relieve the burden on all resources, whereas the RFID system and the discharge lounge together can significantly mitigate the nurses' tasks. The simulation results in terms of the time taken demonstrate that the RFID system can shorten patient wait times, staff busy times, and bed occupation times. The results of the study could prove helpful to others who are considering the use of an RFID system in the patient discharge process in hospitals or similar processes.

  9. Development of corrosion condition sensing and monitoring system using radio-frequency identification devices (RFID)

    Energy Technology Data Exchange (ETDEWEB)

    Gu, G.P.; Zheng, W. [Natural Resources Canada, Ottawa, ON (Canada). CANMET Materials Technology Laboratory

    2008-05-15

    This study discussed the development of a corrosion sensing and monitoring system for military land vehicles. Radio-frequency identification device (RFID) technology uses radio waves to identify individual masses with RFID tags attached. A corrosion-sensing element was integrated with the RFID technology, which incorporated a galvanic corrosion cell designed to trigger RFID tags. Corrosion severity was then related to the galvanic current. The tag recorded the sensor reading and transmitted the data to an RFID reader. The tags consisted of a microchip and an antenna. A software development kit has also been developed to interface RFID data with existing applications. While it is currently not possible to modify the RFID tags to prevent security risks, further research is being conducted to assemble a data-logger system with corrosion probes to measure humidity, electrical resistance, and linear polarization resistance. Studies will also be conducted to assemble an active tag reader system and investigate potential modifications. 4 refs., 1 fig., 1 appendix.

  10. Assessment of outdoor radiofrequency electromagnetic field exposure through hotspot localization using kriging-based sequential sampling

    Energy Technology Data Exchange (ETDEWEB)

    Aerts, Sam, E-mail: sam.aerts@intec.ugent.be; Deschrijver, Dirk; Verloock, Leen; Dhaene, Tom; Martens, Luc; Joseph, Wout

    2013-10-15

    In this study, a novel methodology is proposed to create heat maps that accurately pinpoint the outdoor locations with elevated exposure to radiofrequency electromagnetic fields (RF-EMF) in an extensive urban region (or, hotspots), and that would allow local authorities and epidemiologists to efficiently assess the locations and spectral composition of these hotspots, while at the same time developing a global picture of the exposure in the area. Moreover, no prior knowledge about the presence of radiofrequency radiation sources (e.g., base station parameters) is required. After building a surrogate model from the available data using kriging, the proposed method makes use of an iterative sampling strategy that selects new measurement locations at spots which are deemed to contain the most valuable information—inside hotspots or in search of them—based on the prediction uncertainty of the model. The method was tested and validated in an urban subarea of Ghent, Belgium with a size of approximately 1 km{sup 2}. In total, 600 input and 50 validation measurements were performed using a broadband probe. Five hotspots were discovered and assessed, with maximum total electric-field strengths ranging from 1.3 to 3.1 V/m, satisfying the reference levels issued by the International Commission on Non-Ionizing Radiation Protection for exposure of the general public to RF-EMF. Spectrum analyzer measurements in these hotspots revealed five radiofrequency signals with a relevant contribution to the exposure. The radiofrequency radiation emitted by 900 MHz Global System for Mobile Communications (GSM) base stations was always dominant, with contributions ranging from 45% to 100%. Finally, validation of the subsequent surrogate models shows high prediction accuracy, with the final model featuring an average relative error of less than 2 dB (factor 1.26 in electric-field strength), a correlation coefficient of 0.7, and a specificity of 0.96. -- Highlights: • We present an

  11. Assessment of outdoor radiofrequency electromagnetic field exposure through hotspot localization using kriging-based sequential sampling

    International Nuclear Information System (INIS)

    Aerts, Sam; Deschrijver, Dirk; Verloock, Leen; Dhaene, Tom; Martens, Luc; Joseph, Wout

    2013-01-01

    In this study, a novel methodology is proposed to create heat maps that accurately pinpoint the outdoor locations with elevated exposure to radiofrequency electromagnetic fields (RF-EMF) in an extensive urban region (or, hotspots), and that would allow local authorities and epidemiologists to efficiently assess the locations and spectral composition of these hotspots, while at the same time developing a global picture of the exposure in the area. Moreover, no prior knowledge about the presence of radiofrequency radiation sources (e.g., base station parameters) is required. After building a surrogate model from the available data using kriging, the proposed method makes use of an iterative sampling strategy that selects new measurement locations at spots which are deemed to contain the most valuable information—inside hotspots or in search of them—based on the prediction uncertainty of the model. The method was tested and validated in an urban subarea of Ghent, Belgium with a size of approximately 1 km 2 . In total, 600 input and 50 validation measurements were performed using a broadband probe. Five hotspots were discovered and assessed, with maximum total electric-field strengths ranging from 1.3 to 3.1 V/m, satisfying the reference levels issued by the International Commission on Non-Ionizing Radiation Protection for exposure of the general public to RF-EMF. Spectrum analyzer measurements in these hotspots revealed five radiofrequency signals with a relevant contribution to the exposure. The radiofrequency radiation emitted by 900 MHz Global System for Mobile Communications (GSM) base stations was always dominant, with contributions ranging from 45% to 100%. Finally, validation of the subsequent surrogate models shows high prediction accuracy, with the final model featuring an average relative error of less than 2 dB (factor 1.26 in electric-field strength), a correlation coefficient of 0.7, and a specificity of 0.96. -- Highlights: • We present an

  12. Impact of a radio-frequency identification system and information interchange on clearance processes for cargo at border posts

    Directory of Open Access Journals (Sweden)

    Ernest Bhero

    2015-11-01

    Full Text Available Background: Improved operational efficiency is important to role players in cross-border logistics and trade corridors. Cargo owners and cargo forwarders have been particularly concerned about long delays in the processing and clearing of cargo at border posts. Field studies suggest that these delays are due to a combination of factors, such as a lack of optimum system configurations and non-optimised human-dependent operations, which make the operations prone to corruption and other malpractices. Objectives: This article presents possible strategies for improving some of the operations in this sector. The research hinges on two key questions: (1 what is the impact of information interchange between stakeholders on the cargo transit time and (2 how will cargo transit time be impacted upon by automatic identification of cargo and the status of cargo seals on arriving vehicles at the border? Method: The use of information communication systems enabled by automatic identification systems (incorporating radio-frequency identification technology is suggested. Results: Results obtained by the described simulation model indicate that improvements of up to 82% with regard to transit time are possible using these techniques. Conclusion: The findings therefore demonstrate how operations at border posts can be improved through the use of appropriate technology and configuration of the operations.

  13. The biological effects of quadripolar radiofrequency sequential application: a human experimental study.

    Science.gov (United States)

    Nicoletti, Giovanni; Cornaglia, Antonia Icaro; Faga, Angela; Scevola, Silvia

    2014-10-01

    An experimental study was conducted to assess the effectiveness and safety of an innovative quadripolar variable electrode configuration radiofrequency device with objective measurements in an ex vivo and in vivo human experimental model. Nonablative radiofrequency applications are well-established anti-ageing procedures for cosmetic skin tightening. The study was performed in two steps: ex vivo and in vivo assessments. In the ex vivo assessments the radiofrequency applications were performed on human full-thickness skin and subcutaneous tissue specimens harvested during surgery for body contouring. In the in vivo assessments the applications were performed on two volunteer patients scheduled for body contouring surgery at the end of the study. The assessment methods were: clinical examination and medical photography, temperature measurement with thermal imaging scan, and light microscopy histological examination. The ex vivo assessments allowed for identification of the effective safety range for human application. The in vivo assessments allowed for demonstration of the biological effects of sequential radiofrequency applications. After a course of radiofrequency applications, the collagen fibers underwent an immediate heat-induced rearrangement and were partially denaturated and progressively metabolized by the macrophages. An overall thickening and spatial rearrangement was appreciated both in the collagen and elastic fibers, the latter displaying a juvenile reticular pattern. A late onset in the macrophage activation after sequential radiofrequency applications was appreciated. Our data confirm the effectiveness of sequential radiofrequency applications in obtaining attenuation of the skin wrinkles by an overall skin tightening.

  14. Impact of radio-frequency identification (RFID) technologies on the hospital supply chain: a literature review.

    Science.gov (United States)

    Coustasse, Alberto; Tomblin, Shane; Slack, Chelsea

    2013-01-01

    Supply costs account for more than one-third of the average operating budget and constitute the second largest expenditure in hospitals. As hospitals have sought to reduce these costs, radio-frequency identification (RFID) technology has emerged as a solution. This study reviews existing literature to gauge the recent and potential impact and direction of the implementation of RFID in the hospital supply chain to determine current benefits and barriers of adoption. Findings show that the application of RFID to medical equipment and supplies tracking has resulted in efficiency increases in hospitals with lower costs and increased service quality. RFID technology can reduce costs, improve patient safety, and improve supply chain management effectiveness by increasing the ability to track and locate equipment, as well as monitoring theft prevention, distribution management, and patient billing. Despite ongoing RFID implementation in the hospital supply chain, barriers to widespread and rapid adoption include significant total expenditures, unclear return on investment, and competition with other strategic imperatives.

  15. Impact of Radio-Frequency Identification (RFID) Technologies on the Hospital Supply Chain: A Literature Review

    Science.gov (United States)

    Coustasse, Alberto; Tomblin, Shane; Slack, Chelsea

    2013-01-01

    Supply costs account for more than one-third of the average operating budget and constitute the second largest expenditure in hospitals. As hospitals have sought to reduce these costs, radio-frequency identification (RFID) technology has emerged as a solution. This study reviews existing literature to gauge the recent and potential impact and direction of the implementation of RFID in the hospital supply chain to determine current benefits and barriers of adoption. Findings show that the application of RFID to medical equipment and supplies tracking has resulted in efficiency increases in hospitals with lower costs and increased service quality. RFID technology can reduce costs, improve patient safety, and improve supply chain management effectiveness by increasing the ability to track and locate equipment, as well as monitoring theft prevention, distribution management, and patient billing. Despite ongoing RFID implementation in the hospital supply chain, barriers to widespread and rapid adoption include significant total expenditures, unclear return on investment, and competition with other strategic imperatives. PMID:24159272

  16. Radiofrequency glow discharge time of flight mass spectrometry: pulsed vs. continuous mode

    International Nuclear Information System (INIS)

    Lobo, L.; Pereiro, R.; Sanz-Medel, A.; Bordel, N.; Tempez, A.; Chapon, P.; Hohl, M.; Michler, J.

    2009-01-01

    Full text: Glow discharge (GD) is a well established tool for the direct analysis of solids. The application field of the original direct current GD, restricted to conductive samples, has been extended by radiofrequency powered GDs that can be applied for conductive and non-conductive samples. Moreover, the introduction of pulsed GD has opened the possibility of applying higher instantaneous powers that can improve the atomization-ionization processes and therefore the sensitivity. Furthermore, pulsed-GD may enable temporal separation of discharge gas species from the sample ions. In this work the analytical performances of radiofrequency and pulsed radiofrequency glow discharges are evaluated by using a time of flight mass analyzer (TOFMS). (author)

  17. Benefits and Barriers of Implementation and Utilization of Radio-Frequency Identification (RFID) Systems in Transfusion Medicine.

    Science.gov (United States)

    Coustasse, Alberto; Cunningham, Brian; Deslich, Stacie; Willson, Eric; Meadows, Pamela

    2015-01-01

    Radio-frequency identification (RFID) technology is used by hospital supply chains to track medical products and monitor inventories. Hospitals have also begun incorporating RFID technology as part of their transfusion processes. The purpose of this review was to analyze how healthcare organization supply chains can benefit from the utilization of RFID systems in transfusion service departments. The methodology for this study was a literature review following the steps of a systematic review with a total of 52 sources referenced. RFID technology is used to manage and track blood products from the initial donor phlebotomy to final disposition or product transfusion. RFID-enabled transfusion practices have successfully increased provider productivity and product quality through work-time reduction and error reduction. Findings of this research study suggest that RFID has provided improvements in quality of care and efficiency, while initial costs, security, and privacy appear to be the principal barriers to adoption.

  18. Systematic Review of Radiofrequency Ablation and Pulsed Radiofrequency for Management of Cervicogenic Headaches.

    Science.gov (United States)

    Grandhi, Ravi K; Kaye, Alan David; Abd-Elsayed, Alaa

    2018-02-23

    Cervicogenic headache (CHA) is a secondary headache which has a source in the upper cervical spine. Many traditional analgesic choices lack good efficacy in managing the associated pain. As a result, in management of CHA, radiofrequency ablation (RFA) or pulse radiofrequency (PRF) has been tried with success. Our study investigated the use of RFA and PRF for the management of CHA. In the present investigation, a review of the literature was conducted using PubMed (1966 to February 2017). The quality assessment was determined using The Cochrane Risk of Bias. After initial search and consultation with experts, 34 articles were identified for initial review and 10 articles met inclusion for review. Criteria for inclusion were primarily based on identification of articles discussing cervicogenic headaches which were previously treatment resistant and occurred without any other pathology of the craniofacial region or inciting event such as trauma. This systematic review demonstrated that RFA and PRFA provide very limited benefit in the management of CHA. At present, there is no high-quality RCT and/or strong non-RCTs to support the use of these techniques, despite numerous case reports which have demonstrated benefit. This review is one of the first to provide a comprehensive overview of the use of RFA and PRF in the management of CHA.

  19. WORKSHOPS: Radiofrequency superconductivity

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    In the continual push towards higher energy particle beams, superconducting radiofrequency techniques now play a vital role, highlighted in the fifth workshop on radiofrequency superconductivity, held at DESY from 19 - 24 August 1991

  20. WORKSHOPS: Radiofrequency superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1992-01-15

    In the continual push towards higher energy particle beams, superconducting radiofrequency techniques now play a vital role, highlighted in the fifth workshop on radiofrequency superconductivity, held at DESY from 19 - 24 August 1991.

  1. Radiofrequency Ablation of Lung Tumors

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Radiofrequency Ablation (RFA) / Microwave Ablation (MWA) of Lung Tumors ... and Microwave Ablation of Lung Tumors? What are Radiofrequency and Microwave Ablation of Lung Tumors? Radiofrequency ablation, ...

  2. Development of corrosion condition sensing and monitoring system using radio-frequency identification devices (RFID) : progress report 2

    Energy Technology Data Exchange (ETDEWEB)

    Gu, G.P.; Li, J.; Liu, P.; Bibby, D.; Zheng, W.; Lo, J. [Natural Resources Canada, Ottawa, ON (Canada). CANMET Materials Technology Laboratory

    2008-12-15

    The development of a corrosion severity monitoring system that used radio-frequency identification device (RIFD) technology was discussed. A corrosion monitoring sensor was integrated with a tag modified to partially block the radio frequency signal. The metallic coating caused a frequency shift of the device's reader antenna in order to allow for the accurate characterization of metal coatings. Communications between the tag and the reader were re-established as the corrosion process gradually deteriorated the coating. The method was tested experimentally with 3 RFID systems using both active and passive tags were assembled. A passive tag was covered in aluminum foil. Results of the experiment showed that the metallic coating interfered with RFID signals. A cold-spray technology was used to coat tags with metal alloys. The surface morphology of the coatings was tested to determine optimum coating parameters. Further studies are being conducted to develop software for the technology. 4 refs., 11 figs.

  3. Radiofrequency ablation of osteoid osteoma

    NARCIS (Netherlands)

    Vanderschueren, Geert Maria Joris Michael

    2009-01-01

    The main purpose of this thesis was to evaluate the effectiveness and safety of CT-guided radiofrequency ablation for the treatment of spinal and non-spinal osteoid osteomas. Furthermore, the technical requirements needed for safe radiofrequency ablation and the clinical outcome after radiofrequency

  4. Outdoor stocking density in free-range laying hens: radio-frequency identification of impacts on range use.

    Science.gov (United States)

    Campbell, D L M; Hinch, G N; Dyall, T R; Warin, L; Little, B A; Lee, C

    2017-01-01

    The number and size of free-range laying hen (Gallus gallus domesticus) production systems are increasing within Australia in response to consumer demand for perceived improvement in hen welfare. However, variation in outdoor stocking density has generated consumer dissatisfaction leading to the development of a national information standard on free-range egg labelling by the Australian Consumer Affairs Ministers. The current Australian Model Code of Practice for Domestic Poultry states a guideline of 1500 hens/ha, but no maximum density is set. Radio-frequency identification (RFID) tracking technology was used to measure daily range usage by individual ISA Brown hens housed in six small flocks (150 hens/flock - 50% of hens tagged), each with access to one of three outdoor stocking density treatments (two replicates per treatment: 2000, 10 000, 20 000 hens/ha), from 22 to 26, 27 to 31 and 32 to 36 weeks of age. There was some variation in range usage across the sampling periods and by weeks 32 to 36 individual hens from the lowest stocking density on average used the range for longer each day (Prange with 2% of tagged hens in each treatment never venturing outdoors and a large proportion that accessed the range daily (2000 hens/ha: 80.5%; 10 000 hens/ha: 66.5%; 20 000 hens/ha: 71.4%). On average, 38% to 48% of hens were seen on the range simultaneously and used all available areas of all ranges. These results of experimental-sized flocks have implications for determining optimal outdoor stocking densities for commercial free-range laying hens but further research would be needed to determine the effects of increased range usage on hen welfare.

  5. Percutaneous radiofrequency treatment of osteoid osteoma using cool-tip electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Martel, Jose [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Avda. de Budapest s/n, 28922 Alcorcon, Madrid (Spain)]. E-mail: jmartel@fhalcorcon.es; Bueno, Angel [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Avda. de Budapest s/n, 28922 Alcorcon, Madrid (Spain); Ortiz, Eduardo [Departamento de Cirugia ortopedica, Fundacion Hospital Alcorcon, Madrid (Spain)

    2005-12-15

    Objectives: To report our experience with percutaneous cool-tip radiofrequency ablation of osteoid osteomas and to evaluate clinical outcome. Methods and material: Forty-one patients with clinically and radiologically suspected osteoid osteoma were seen over a 48-month period (27 males and 14 females with a mean age of 18.7 years; range 5-43 years). Thirty-eight patients were treated by computed tomography (CT)-guided percutaneous radiofrequency ablation. The procedure was performed under regional or general anaesthesia. After location of the nidus, a 14G-bone biopsy needle is introduced into the nidus. Sampling is performed with a 17G-bone biopsy needle using a coaxial technique. The radiofrequency needle with a 10 mm active tip (cool-tip) is inserted through the biopsy needle and is connected to the radiofrequency generator for 6-8 min. Results: Primary success was obtained in 37 patients (97%) with a 100% secondary success rate. All patients are currently pain-free. No major complications occurred. Patients could resume unrestricted normal activity within 24 h. Conclusions: Percutaneous radiofrequency ablation of osteoid osteomas is an efficient and safe method that can be considered the procedure of choice for most cases.

  6. Contactless and absolute linear displacement detection based upon 3D printed magnets combined with passive radio-frequency identification

    Science.gov (United States)

    Windl, Roman; Abert, Claas; Bruckner, Florian; Huber, Christian; Vogler, Christoph; Weitensfelder, Herbert; Suess, Dieter

    2017-11-01

    Within this work a passive and wireless magnetic sensor, to monitor linear displacements, is proposed. We exploit recent advances in 3D printing and fabricate a polymer bonded magnet with a spatially linear magnetic field component corresponding to the length of the magnet. Regulating the magnetic compound fraction during printing allows specific shaping of the magnetic field distribution. A giant magnetoresistance magnetic field sensor is combined with a radio-frequency identification tag in order to passively monitor the exerted magnetic field of the printed magnet. Due to the tailored magnetic field, a displacement of the magnet with respect to the sensor can be detected within the sub-mm regime. The sensor design provides good flexibility by controlling the 3D printing process according to application needs. Absolute displacement detection using low cost components and providing passive operation, long term stability, and longevity renders the proposed sensor system ideal for structural health monitoring applications.

  7. Contactless and absolute linear displacement detection based upon 3D printed magnets combined with passive radio-frequency identification

    Directory of Open Access Journals (Sweden)

    Roman Windl

    2017-11-01

    Full Text Available Within this work a passive and wireless magnetic sensor, to monitor linear displacements, is proposed. We exploit recent advances in 3D printing and fabricate a polymer bonded magnet with a spatially linear magnetic field component corresponding to the length of the magnet. Regulating the magnetic compound fraction during printing allows specific shaping of the magnetic field distribution. A giant magnetoresistance magnetic field sensor is combined with a radio-frequency identification tag in order to passively monitor the exerted magnetic field of the printed magnet. Due to the tailored magnetic field, a displacement of the magnet with respect to the sensor can be detected within the sub-mm regime. The sensor design provides good flexibility by controlling the 3D printing process according to application needs. Absolute displacement detection using low cost components and providing passive operation, long term stability, and longevity renders the proposed sensor system ideal for structural health monitoring applications.

  8. 47 CFR 2.801 - Radiofrequency device defined.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Radiofrequency device defined. 2.801 Section 2... MATTERS; GENERAL RULES AND REGULATIONS Marketing of Radio-frequency Devices § 2.801 Radiofrequency device defined. As used in this part, a radiofrequency device is any device which in its operation is capable of...

  9. Utilizing Radiofrequency Identification Technology to Improve Safety and Management of Blood Bank Supply Chains.

    Science.gov (United States)

    Coustasse, Alberto; Meadows, Pamela; Hall, Robert S; Hibner, Travis; Deslich, Stacie

    2015-11-01

    The importance of efficiency in the supply chain of perishable products, such as the blood products used in transfusion services, cannot be overstated. Many problems can occur, such as the outdating of products, inventory management issues, patient misidentification, and mistransfusion. The purpose of this article was to identify the benefits and barriers associated with radiofrequency identification (RFID) usage in improving the blood bank supply chain. The methodology for this study was a qualitative literature review following a systematic approach. The review was limited to sources published from 2000 to 2014 in the English language. Sixty-five sources were found, and 56 were used in this research study. According to the finding of the present study, there are numerous benefits and barriers to RFID utilization in blood bank supply chains. RFID technology offers several benefits with regard to blood bank product management, including decreased transfusion errors, reduction of product loss, and more efficient inventory management. Barriers to RFID implementation include the cost associated with system implementation and patient privacy issues. Implementation of an RFID system can be a significant investment. However, when observing the positive impact that such systems may have on transfusion safety and inventory management, the cost associated with RFID systems can easily be justified. RFID in blood bank inventory management is vital to ensuring efficient product inventory management and positive patient outcomes.

  10. Medium-Sized Mammals around a Radioactive Liquid Waste Lagoon at Los Alamos National Laboratory: Uptake of Contaminants and Evaluation of Radio-Frequency Identification Technology

    Energy Technology Data Exchange (ETDEWEB)

    Leslie A. Hansen; Phil R. Fresquez; Rhonda J. Robinson; John D. Huchton; Teralene S. Foxx

    1999-11-01

    Use of a radioactive liquid waste lagoon by medium-sized mammals and levels of tritium, other selected radionuclides, and metals in biological tissues of the animals were documented at Technical Area 53 (TA-53) of Los Alamos National Laboratory during 1997 and 1998. Rock squirrel (Spermophilus variegates), raccoon (Procyon lotor), striped skunk (Mephitis mephitis), and bobcat (Lynx rufus) were captured at TA-53 and at a control site on the Santa Fe National Forest. Captured animals were anesthetized and marked with radio-frequency identification (RFD) tags and/or ear tags. We collected urine and hair samples for tritium and metals (aluminum, antimony, arsenic, barium, beryllium, cadmium, chromium, copper, lead, mercury, nickel, selenium, silver, and thallium) analyses, respectively. In addition, muscle and bone samples from two rock squirrels collected from each of TA-53, perimeter, and regional background sites were tested for tritium, {sup 137}Cs, {sup 90}Sr, {sup 238}Pu, {sup 239,240}Pu, {sup 241}Am, and total uranium. Animals at TA-53 were monitored entering and leaving the lagoon area using a RFID monitor to read identification numbers from the RFID tags of marked animals and a separate camera system to photograph all animals passing through the monitor. Cottontail rabbit (Sylvilagus spp.), rock squirrel, and raccoon were the species most frequently photographed going through the RFID monitor. Less than half of all marked animals in the lagoon area were detected using the lagoon. Male and female rock squirrels from the lagoon area had significantly higher tritium concentrations compared to rock squirrels from the control area. Metals tested were not significantly higher in rock squirrels from TA-53, although there was a trend toward increased levels of lead in some individuals at TA-53. Muscle and bone samples from squirrels in the lagoon area appeared to have higher levels of tritium, total uranium, and {sup 137}Cs than samples collected from perimeter and

  11. Conventional Radiofrequency Thermocoagulation vs Pulsed Radiofrequency Neuromodulation of Ganglion Impar in Chronic Perineal Pain of Nononcological Origin.

    Science.gov (United States)

    Usmani, Hammad; Dureja, G P; Andleeb, Roshan; Tauheed, Nazia; Asif, Naiyer

    2018-01-10

    Chronic nononcological perineal pain has been effectively managed by ganglion Impar block. Chemical neurolysis, cryoablation, and radiofrequency ablation have been the accepted methods of blockade. Recently, pulsed radiofrequency, a novel variant of conventional radiofrequency, has been used for this purpose. This was a prospective, randomized, double-blind study. Two different interventional pain management centers in India. To compare the efficacy of conventional radiofrequency and pulsed radiofrequency for gangliom Impar block. The patients were randomly allocated to one of two groups. In the conventional radiofrequency (CRF) group (N = 34), conventional radiofrequency ablation was done, and in the PRF pulsed radiofrequency (PRF) group (N = 31), pulsed radiofrequency ablation was done. After informed and written consent, fluoroscopy-guided ganglion Impar block was performed through the first intracoccygeal approach. The extent of pain relief was assessed by visual analog scale (VAS) at 24 hours, and at the first, third, and sixth weeks following the intervention. A questionnaire to evaluate subjective patient satisfaction was also used at each follow-up visit. In the CRF group, the mean VAS score decreased significantly from the baseline value at each follow-up visit. But in the PRF group, this decrease was insignificant except at 24-hour follow-up. Intergroup comparison also showed significantly better pain relief in the CRF group as compared with the PRF group. At the end of follow-up, 28 patients (82%) in the CRF group and four patients (13%) in the PRF group had excellent results, as assessed by the subjective patient satisfaction questionnaire. There was no complication in any patient of either study group, except for short-lived infection at the site of skin puncture in a few. Ganglion Impar block by conventional radiofrequency provided a significantly better quality of pain relief with no major side effects in patients with chronic

  12. Radiofrequency ablation in dermatology

    Directory of Open Access Journals (Sweden)

    Sachdeva Silonie

    2007-01-01

    Full Text Available Radiofreqeuency ablation is a versatile dermatosurgical procedure used for surgical management of skin lesions by using various forms of alternating current at an ultra high frequency. The major modalities in radiofrequency are electrosection, electrocoagulation, electrodessication and fulguration. The use of radiofrequency ablation in dermatosurgical practice has gained importance in recent years as it can be used to treat most of the skin lesions with ease in less time with clean surgical field due to adequate hemostasis and with minimal side effects and complications. This article focuses on the major tissue effects and factors influencing radiofrequency ablation and its application for various dermatological conditions.

  13. CT-guided radiofrequency tumor ablation in children

    International Nuclear Information System (INIS)

    Botsa, Evanthia; Poulou, Loukia S.; Koundouraki, Antonia; Thanos, Loukas; Koutsogiannis, Ioannis; Ziakas, Panayiotis D.; Alexopoulou, Efthimia

    2014-01-01

    Image-guided radiofrequency ablation is a well-accepted technique of interventional oncology in adults. To evaluate the efficacy and safety of CT-guided radiofrequency ablation as a minimally invasive treatment for metastatic neoplasms in children. A total of 15 radiofrequency ablation sessions were performed in 12 children and young adults (median age 9.5; range 5-18 years) with metastatic malignancies. Seven children and young adults had secondary hepatic lesions, three had pulmonary and two had bone lesions. Radiofrequency ablation was performed under conscious sedation. The median lesion size was 1.7 cm (range 1.3-2.8 cm). The median time for ablation was 8 min (range 7-10 min). Radiofrequency procedures were technically successful in all tumors. Postablation imaging immediately after, and 1 month and 3 months after radiofrequency ablation showed total necrosis in all patients. At 6-month follow-up, three patients (all with lesion size >2 cm) had local recurrence and underwent a second radiofrequency ablation session. At 2-year follow-up no patient had recurrence of the treated tumor. Post-ablation syndrome occurred in four children. No major complication occurred. CT-guided radiofrequency tumor ablation was safe and efficient for palliative treatment in our cohort of patients. (orig.)

  14. CT-guided radiofrequency tumor ablation in children

    Energy Technology Data Exchange (ETDEWEB)

    Botsa, Evanthia [National and Kapodistrian University of Athens, First Pediatric Clinic, Agia Sofia Children' s Hospital, Athens (Greece); Poulou, Loukia S.; Koundouraki, Antonia; Thanos, Loukas [Sotiria General Hospital for Chest Diseases, Department of Medical Imaging and Interventional Radiology, Athens (Greece); Koutsogiannis, Ioannis [General Military Hospital NIMTS, Department of Medical Imaging, Athens (Greece); Ziakas, Panayiotis D. [Warren Alpert Medical School of Brown University Rhode Island Hospital, Division of Infectious Diseases, Providence, RI (United States); Alexopoulou, Efthimia [Attikon University Hospital, Second Department of Radiology, Athens University School of Medicine, Athens (Greece)

    2014-11-15

    Image-guided radiofrequency ablation is a well-accepted technique of interventional oncology in adults. To evaluate the efficacy and safety of CT-guided radiofrequency ablation as a minimally invasive treatment for metastatic neoplasms in children. A total of 15 radiofrequency ablation sessions were performed in 12 children and young adults (median age 9.5; range 5-18 years) with metastatic malignancies. Seven children and young adults had secondary hepatic lesions, three had pulmonary and two had bone lesions. Radiofrequency ablation was performed under conscious sedation. The median lesion size was 1.7 cm (range 1.3-2.8 cm). The median time for ablation was 8 min (range 7-10 min). Radiofrequency procedures were technically successful in all tumors. Postablation imaging immediately after, and 1 month and 3 months after radiofrequency ablation showed total necrosis in all patients. At 6-month follow-up, three patients (all with lesion size >2 cm) had local recurrence and underwent a second radiofrequency ablation session. At 2-year follow-up no patient had recurrence of the treated tumor. Post-ablation syndrome occurred in four children. No major complication occurred. CT-guided radiofrequency tumor ablation was safe and efficient for palliative treatment in our cohort of patients. (orig.)

  15. RADIOFREQUENCY SUPERCONDUCTIVITY: Workshop

    International Nuclear Information System (INIS)

    Lengeler, Herbert

    1989-01-01

    Superconducting radiofrequency is already playing an important role in the beam acceleration system for the TRISTAN electron-positron collider at the Japanese KEK Laboratory and new such systems are being prepared for other major machines. Thus the fourth Workshop on Radiofrequency Superconductivity, organized by KEK under the chairmanship of local specialist Yuzo Kojima and held just before the International Conference on High Energy Accelerators, had much progress to review and even more to look forward to

  16. Accuracy of a radiofrequency identification (RFID) badge system to monitor hand hygiene behavior during routine clinical activities.

    Science.gov (United States)

    Pineles, Lisa L; Morgan, Daniel J; Limper, Heather M; Weber, Stephen G; Thom, Kerri A; Perencevich, Eli N; Harris, Anthony D; Landon, Emily

    2014-02-01

    Hand hygiene (HH) is a critical part of infection prevention in health care settings. Hospitals around the world continuously struggle to improve health care personnel (HCP) HH compliance. The current gold standard for monitoring compliance is direct observation; however, this method is time-consuming and costly. One emerging area of interest involves automated systems for monitoring HH behavior such as radiofrequency identification (RFID) tracking systems. To assess the accuracy of a commercially available RFID system in detecting HCP HH behavior, we compared direct observation with data collected by the RFID system in a simulated validation setting and to a real-life clinical setting over 2 hospitals. A total of 1,554 HH events was observed. Accuracy for identifying HH events was high in the simulated validation setting (88.5%) but relatively low in the real-life clinical setting (52.4%). This difference was significant (P RFID system, almost half of the HH events were missed. More research is necessary to further develop these systems and improve accuracy prior to widespread adoption. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  17. Reverse sample genome probing, a new technique for identification of bacteria in environmental samples by DNA hybridization, and its application to the identification of sulfate-reducing bacteria in oil field samples

    International Nuclear Information System (INIS)

    Voordouw, G.; Voordouw, J.K.; Karkhoff-Schweizer, R.R.; Fedorak, P.M.; Westlake, D.W.S.

    1991-01-01

    A novel method for identification of bacteria in environmental samples by DNA hybridization is presented. It is based on the fact that, even within a genus, the genomes of different bacteria may have little overall sequence homology. This allows the use of the labeled genomic DNA of a given bacterium (referred to as a standard) to probe for its presence and that of bacteria with highly homologous genomes in total DNA obtained from an environmental sample. Alternatively, total DNA extracted from the sample can be labeled and used to probe filters on which denatured chromosomal DNA from relevant bacterial standards has been spotted. The latter technique is referred to as reverse sample genome probing, since it is the reverse of the usual practice of deriving probes from reference bacteria for analyzing a DNA sample. Reverse sample genome probing allows identification of bacteria in a sample in a single step once a master filter with suitable standards has been developed. Application of reverse sample genome probing to the identification of sulfate-reducing bacteria in 31 samples obtained primarily from oil fields in the province of Alberta has indicated that there are at least 20 genotypically different sulfate-reducing bacteria in these samples

  18. Radiofrequency Energy and Electrode Proximity Influences Stereoelectroencephalography-Guided Radiofrequency Thermocoagulation Lesion Size: An In Vitro Study with Clinical Correlation.

    Science.gov (United States)

    Staudt, Michael D; Maturu, Sarita; Miller, Jonathan P

    2018-02-16

    Radiofrequency thermocoagulation of epileptogenic foci via stereoelectroencephalography (SEEG) electrodes has been suggested as a treatment for medically intractable epilepsy, but reported outcomes have been suboptimal, possibly because lesions generated using conventional high-energy radiofrequency parameters are relatively small. To describe a technique of delivering low energy across separate SEEG electrodes in order to create large confluent radiofrequency lesions. The size and configuration of radiofrequency lesions using different radiofrequency intensity and interelectrode distance was assessed in egg whites. Magnetic resonance images (MRI) from 3 patients who had undergone radiofrequency lesion creation were evaluated to determine the contribution of lesion intensity and electrode separation on lesion size. Electroencephalography, MRI, and clinical data were assessed before and after lesion creation. Both in Vitro and in Vivo analysis revealed that less energy paradoxically produced larger lesions, with the largest possible lesions produced when radiofrequency power was applied for long duration at less than 3 W. Linear separation of electrodes also contributed to lesion size, with largest lesions produced when electrodes were separated by a linear distance of between 5 and 12 mm. Clinical lesions produced using these parameters were large and resulted in improvement in interictal and ictal activity. Radiofrequency lesions produced using low-energy delivery between SEEG electrodes in close proximity can produce a large lesion. These findings might have advantages for treatment of focal epilepsy.

  19. Radiofrequency ablation of hepatocellular carcinoma: Mono or multipolar?

    Science.gov (United States)

    Cartier, Victoire; Boursier, Jérôme; Lebigot, Jérôme; Oberti, Frédéric; Fouchard-Hubert, Isabelle; Aubé, Christophe

    2016-03-01

    Thermo-ablation by radiofrequency is recognized as a curative treatment for early-stage hepatocellular carcinoma. However, local recurrence may occur because of incomplete peripheral tumor destruction. Multipolar radiofrequency has been developed to increase the size of the maximal ablation zone. We aimed to compare the efficacy of monopolar and multipolar radiofrequency for the treatment of hepatocellular carcinoma and determine factors predicting failure. A total of 171 consecutive patients with 214 hepatocellular carcinomas were retrospectively included. One hundred fifty-eight tumors were treated with an expandable monopolar electrode and 56 with a multipolar technique using several linear bipolar electrodes. Imaging studies at 6 weeks after treatment, then every 3 months, assessed local effectiveness. Radiofrequency failure was defined as persistent residual tumor after two sessions (primary radiofrequency failure) or local tumor recurrence during follow-up. This study received institutional review board approval (number 2014/77). Imaging showed complete tumor ablation in 207 of 214 lesions after the first session of radiofrequency. After a second session, only two cases of residual viable tumor were observed. During follow-up, there were 46 local tumor recurrences. Thus, radiofrequency failure occurred in 48/214 (22.4%) cases. By multivariate analysis, technique (P radiofrequency failure. Failure rate was lower with the multipolar technique for tumors radiofrequency, multipolar radiofrequency improves tumor ablation with a subsequent lower rate of local tumor recurrence. © 2015 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  20. Measurement of radiofrequency fields

    International Nuclear Information System (INIS)

    Leonowich, J.A.

    1992-05-01

    We are literally surrounded by radiofrequency (RFR) and microwave radiation, from both natural and man-made sources. The identification and control of man-made sources of RFR has become a high priority of radiation safety professionals in recent years. For the purposes of this paper, we will consider RFR to cover the frequencies from 3 kHz to 300 MHz, and microwaves from 300 MHz to 300 GHz, and will use the term RFR interchangeably to describe both. Electromagnetic radiation and field below 3 kHz is considered Extremely Low Frequency (ELF) and will not be discussed in this paper. Unlike x- and gamma radiation, RFR is non-ionizing. The energy of any RFR photon is insufficient to produce ionizations in matter. The measurement and control of RFR hazards is therefore fundamentally different from ionizing radiation. The purpose of this paper is to acquaint the reader with the fundamental issues involved in measuring and safely using RFR fields. 23 refs

  1. Pulse-dose radiofrequency treatment in pain management-initial experience.

    Science.gov (United States)

    Ojango, Christine; Raguso, Mario; Fiori, Roberto; Masala, Salvatore

    2018-05-01

    Radiofrequency procedures have been used for treating various chronic pain conditions for decades. These minimally invasive percutaneous treatments employ an alternating electrical current with oscillating radiofrequency wavelengths to eliminate or alter pain signals from the targeted site. The aim of the continuous radiofrequency procedure is to increase the temperature sufficiently to create an irreversible thermal lesion on nerve fibres and thus permanently interrupt pain signals. The pulsed radiofrequency procedure utilises short pulses of radiofrequency current with intervals of longer pauses to avert a temperature increase to the level of permanent tissue damage. The goal of these pulses is to alter the processing of pain signals, but to avoid relevant structural damage to nerve fibres, as seen in the continuous radiofrequency procedure. The pulse-dose radiofrequency procedure is a technical improvement of the pulsed radiofrequency technique in which the delivery mode of the current is adapted. During the pulse-dose radiofrequency procedure thermal damage is avoided. In addition, the amplitude and width of the consecutive pulses are kept the same. The method ensures that each delivered pulse keeps the same characteristics and therefore the dose is similar between patients. The current review outlines the pulse-dose radiofrequency procedure and presents our institution's chronic pain management studies.

  2. A survey on monopolar radiofrequency treatment.

    Science.gov (United States)

    Suh, Dong Hye; Hong, Eun Sun; Kim, Hyun Joo; Lee, Sang Jun; Kim, Hei Sung

    2017-09-01

    This questionnaire-based study was aimed to measure the level of appreciation, awareness of the special tips, and practice patterns of monopolar radiofrequency among Korean dermatologists practicing a specific monopolar radiofrequency device (Thermage® Inc., Hayward, CA). A total of 82 surveys were analyzed to show that the majority of participants (78.8%) were highly satisfied with the outcomes of monopolar radiofrequency treatment. All respondents were aware of the Eye Tip 0.25 cm 2 , and the majority knew the difference between the Face tip (blue) and the Total tip (orange). Most (86.3%) agreed to the statement that 900 shots were appropriate for facial tightening in those between the ages of 35 and 65 years. 66.2% of participants reported to have perform monopolar radiofrequency to extra-facial sites within the past year. As for the tips, the Total tip was most popular for all body sties and the Big tip was favored for the abdomen, thighs and buttock. We hope our data allow dermatologists to better utilize monopolar radiofrequency. © 2017 Wiley Periodicals, Inc.

  3. Patient and Sample Identification. Out of the Maze?

    Directory of Open Access Journals (Sweden)

    Lippi Giuseppe

    2017-04-01

    Full Text Available Background: Patient and sample misidentification may cause significant harm or discomfort to the patients, especially when incorrect data is used for performing specific healthcare activities. It is hence obvious that efficient and quality care can only start from accurate patient identification. There are many opportunities for misidentification in healthcare and laboratory medicine, including homonymy, incorrect patient registration, reliance on wrong patient data, mistakes in order entry, collection of biological specimens from wrong patients, inappropriate sample labeling and inaccurate entry or erroneous transmission of test results through the laboratory information system. Many ongoing efforts are made to prevent this important healthcare problem, entailing streamlined strategies for identifying patients throughout the healthcare industry by means of traditional and innovative identifiers, as well as using technologic tools that may enhance both the quality and efficiency of blood tubes labeling. The aim of this article is to provide an overview about the liability of identification errors in healthcare, thus providing a pragmatic approach for diverging the so-called patient identification crisis.

  4. Temperature-controlled irrigated tip radiofrequency catheter ablation

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, Adrian

    1998-01-01

    INTRODUCTION: In patients with ventricular tachycardias due to structural heart disease, catheter ablation cures radiofrequency ablation. Irrigated tip radiofrequency ablation using power control and high infusion rates enlarges lesion......: We conclude that temperature-controlled radiofrequency ablation with irrigated tip catheters using low target temperature and low infusion rate enlarges lesion size without increasing the incidence of cratering and reduces coagulum formation of the tip....

  5. Radiofrequency Ablation of Hepatic Cysts : Case Report

    International Nuclear Information System (INIS)

    Lee, Ye Ri; Kim, Pyo Nyun

    2005-01-01

    Radiofrequency ablation has been frequently performed on intra-hepatic solid tumor, namely, hepatocellular carcinoma, metastatic tumor and cholangio carcinoma, for take the cure. But, the reports of radiofrequency ablation for intrahepatic simple cysts are few. In vitro experiment of animal and in vivo treatment for intrahepatic cysts of human had been reported in rare cases. We report 4 cases of radiofrequency ablation for symptomatic intrahepatic cysts

  6. Application of digital sampling techniques to particle identification in scintillation detectors

    International Nuclear Information System (INIS)

    Bardelli, L.; Bini, M.; Poggi, G.; Taccetti, N.

    2002-01-01

    In this paper, the use of a fast digitizing system for identification of fast charged particles with scintillation detectors is discussed. The three-layer phoswich detectors developed in the framework of the FIASCO experiment for the detection of light charged particles (LCP) and intermediate mass fragments (IMF) emitted in heavy-ion collisions at Fermi energies are briefly discussed. The standard analog electronics treatment of the signals for particle identification is illustrated. After a description of the digitizer designed to perform a fast digital sampling of the phoswich signals, the feasibility of particle identification on the sampled data is demonstrated. The results obtained with two different pulse shape discrimination analyses based on the digitally sampled data are compared with the standard analog signal treatment. The obtained results suggest, for the present application, the replacement of the analog methods with the digital sampling technique

  7. Ablation of liver metastases by radiofrequency

    International Nuclear Information System (INIS)

    Baere, T. de

    2012-01-01

    Radiofrequency is a thermal ablative technique that is most often used percuteanously under image guidance. Thermal damage is obtained through frictional heating of a high frequency current. The maximal volume of destruction obtained in one radiofrequency delivery is around 4 cm and consequently, best indication for treatment are tumours below 3 cm. When compared, radiofrequency and surgical removal for tumours below 25 mm in diameter demonstrated a rate of incomplete resection/ablation of 6% and 7.3% respectively. Median survival after the first radiofrequency of a liver metastasis of CRC is reported to be 24 to 52 months with a 5 years overall survival of 18 to 44%. The median overall survival increases from 22 to 48 months depending on the use of radiofrequency ablation as rescue treatment after failure of others, or as a first line treatment. For patients with a single tumour, less than 4 cm, the survival rates at 1, 3, and 5 years are respectively 97%, 84% and 40%, with a median survival of 50 months. Follow-up imaging requires to use contrast-enhanced CT or MRI, looking for local recurrences evidenced by local foci of enhancement at the periphery of the ablation zone. (author)

  8. 47 CFR 1.1310 - Radiofrequency radiation exposure limits.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Radiofrequency radiation exposure limits. 1... Procedures Implementing the National Environmental Policy Act of 1969 § 1.1310 Radiofrequency radiation... exposure to radiofrequency (RF) radiation as specified in § 1.1307(b), except in the case of portable...

  9. Saline-enhanced radiofrequency electrocoagulation in bovine liver

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hong Seop; Oh, Joo Hyeong; Yoon, Yup; Kim, Hyun Cheol; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won; Kim, Eui Jong [Kyunghee Univ. Hospital, Seoul (Korea, Republic of)

    1997-08-01

    To determine the effectiveness of saline-enhanced radiofrequency electrocoagulation in bovine liver tissue Saline-enhanced radiofrequency electrocoagulation (group I), hot saline injection induced by radiofrequency electrocoagulation (group II), and radiofrequency electrocoagulation (group III) were performed in ex vivo bovine liver. Radiofrequency power was 100 and 200 watts, and current was applied for 10, 20, and 30 seconds. Tissue was histopathologically examined for thermal injury. The largest diameter of thermal injury was about 41.0 mm in group I, 12.3 mm in group II and 9.3 mm in group III. The mean diameter of the injury increased with higher wattage in group I and II and with longer procedure time in group I (p<0.05). At corresponding wattage and times, group I showed a larger diameter of thermal injury and more increase in than group II or III (p<0.05). The degree of carbonization was more severe in group III than in groups I and II. Grossly, thermal injury showed a well-defined, relatively spherical configuration without extension along parenchymal interstitium. In an animal model, saline-enhanced radiofrequency electrocoagulation may effectively induce thermal injury, and may thus be another effective tool for use in the treatment of hepatic tumors. Further clinical experience is needed.

  10. Saline-enhanced radiofrequency electrocoagulation in bovine liver

    International Nuclear Information System (INIS)

    Shin, Hong Seop; Oh, Joo Hyeong; Yoon, Yup; Kim, Hyun Cheol; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won; Kim, Eui Jong

    1997-01-01

    To determine the effectiveness of saline-enhanced radiofrequency electrocoagulation in bovine liver tissue Saline-enhanced radiofrequency electrocoagulation (group I), hot saline injection induced by radiofrequency electrocoagulation (group II), and radiofrequency electrocoagulation (group III) were performed in ex vivo bovine liver. Radiofrequency power was 100 and 200 watts, and current was applied for 10, 20, and 30 seconds. Tissue was histopathologically examined for thermal injury. The largest diameter of thermal injury was about 41.0 mm in group I, 12.3 mm in group II and 9.3 mm in group III. The mean diameter of the injury increased with higher wattage in group I and II and with longer procedure time in group I (p<0.05). At corresponding wattage and times, group I showed a larger diameter of thermal injury and more increase in than group II or III (p<0.05). The degree of carbonization was more severe in group III than in groups I and II. Grossly, thermal injury showed a well-defined, relatively spherical configuration without extension along parenchymal interstitium. In an animal model, saline-enhanced radiofrequency electrocoagulation may effectively induce thermal injury, and may thus be another effective tool for use in the treatment of hepatic tumors. Further clinical experience is needed

  11. Image-guided radiofrequency ablation of renal cell carcinoma

    International Nuclear Information System (INIS)

    Boss, Andreas; Clasen, Stephan; Pereira, Philippe L.; Kuczyk, Markus; Schick, Fritz

    2007-01-01

    The incidence of renal cell carcinoma is rising with the increased number of incidental detection of small tumours. During the past few years, percutaneous imaging-guided radiofrequency ablation has evolved as a minimally invasive treatment of small unresectable renal tumours offering reduced patient morbidity and overall health care costs. In radiofrequency ablation, thermal energy is deposited into a targeted tumour by means of a radiofrequency applicator. In recent studies, radiofrequency ablation was shown to be an effective and safe modality for local destruction of renal cell carcinoma. Radiofrequency applicator navigation can be performed via ultrasound, computed tomography or magnetic resonance guidance; however, ultrasound seems less favourable because of the absence of monitoring capabilities during ablation. On-line monitoring of treatment outcome can only be performed with magnetic resonance imaging giving the possibility of eventual applicator repositioning to ablate visible residual tumour tissue. Long-term follow-up is crucial to assess completeness of tumour ablation. New developments in ablation technology and radiological equipment will further increase the indication field for radiofrequency ablation of renal cell carcinoma. Altogether, radiofrequency ablation seems to be a promising new modality for the minimally invasive treatment of renal cell carcinoma, which was demonstrated to exhibit high short-term effectiveness. (orig.)

  12. New-generation radiofrequency technology.

    Science.gov (United States)

    Krueger, Nils; Sadick, Neil S

    2013-01-01

    Radiofrequency (RF) technology has become a standard treatment in aesthetic medicine with many indications due to its versatility, efficacy, and safety. It is used worldwide for cellulite reduction; acne scar revision; and treatment of hypertrophic scars and keloids, rosacea, and inflammatory acne in all skin types. However, the most common indication for RF technology is the nonablative tightening of tissue to improve skin laxity and reduce wrinkles. Radiofrequency devices are classified as unipolar, bipolar, or multipolar depending on the number of electrodes used. Additional modalities include fractional RF; sublative RF; phase-controlled RF; and combination RF therapies that apply light, massage, or pulsed electromagnetic fields (PEMFs). This article reviews studies and case series on these devices. Radiofrequency technology for aesthetic medicine has seen rapid advancements since it was used for skin tightening in 2003. Future developments will continue to keep RF technology at the forefront of the dermatologist's armamentarium for skin tightening and rejuvenation.

  13. Could the Pharmaceutical Industry Benefit from Full-Scale Adoption of Radio-Frequency Identification (RFID) Technology with New Regulations?

    Science.gov (United States)

    Coustasse, Alberto; Kimble, Craig A; Stanton, Robert B; Naylor, Mariah

    2016-01-01

    Healthcare regulators are directing attention to the pharmaceutical supply chain with the passage of the Drug Quality and Security Act (DQSA) and the Drug Supply Chain Security Act (DSCSA). Adoption of Radio-Frequency Identification (RFID) technology has the ability to improve compliance, reduce costs, and improve safety in the supply chain but its implementation has been limited; primarily because of hardware and tag costs. The purpose of this research study was to analyze the benefits to the pharmaceutical industry and healthcare system of the adoption of RFID technology as a result of newly implemented supply chain regulations. The methodology was a review following the steps of a systematic review with a total of 96 sources used. With the DSCSA, pharmaceutical companies must track and trace prescription drugs across the supply chain, and RFID can resolve many track-and-trace issues with manufacturer control of data. The practical implication of this study is that pharmaceutical companies must continue to have the potential to increase revenues, decrease associated costs, and increase compliance with new FDA regulations with RFID. Still, challenges related to regulatory statute wording, implementation of two-dimensional barcode technology, and the variety of interfaces within the pharmaceutical supply chain have delayed adoption and its full implementation.

  14. Challenges with the introduction of radio-frequency identification systems into a manufacturer's supply chain - a pilot study

    Science.gov (United States)

    Kumar, Sameer; Kadow, Brooke B.; Lamkin, Melissa K.

    2011-05-01

    As radio-frequency identification (RFID) implementation becomes more widespread it is important for managers to consider if this technology is right for their businesses. This study examines challenges of RFID implementation along with a cost-benefit analysis of a pharmaceuticals manufacturer's supply chain. Research was gathered from a variety of sources on the topic of RFID to provide an in-depth analysis of challenges and benefits found with RFID systems. Furthermore, the study reviews the real case applications of the RFID technology in healthcare and customer services. Many of the challenges with RFID stem from improper planning of the synchronisation of the supply chain and the integration of RFID technology into facilities and software systems. Customer privacy, excess information and obsolete technology are also of concern to companies considering RFID. Benefits such as increased information sharing, product visibility and real-time information help to offset these challenges. In addition, pharmaceuticals manufacturer real case application showed cost savings from reducing labour and decreased opportunities for lost product counteract the expense to implement an RFID system. This study will be of value to managers who are attempting to implement RFID technology in their companies. It is intended that readers, both academics and practitioners, will be able to identify possible challenges and mitigate them as the RFID technology is put into practice.

  15. Sampling and identification of gaseous and particle bounded air pollutants

    International Nuclear Information System (INIS)

    Kettrup, A.

    1993-01-01

    Air pollutants are gaseous, components of aerosols or particle bounded. Sampling, sample preparation, identification and quantification of compounds depend from kind and chemical composition of the air pollutants. Quality assurance of analytical data must be guaranted. (orig.) [de

  16. Identification of continuous-time systems from samples of input ...

    Indian Academy of Sciences (India)

    Abstract. This paper presents an introductory survey of the methods that have been developed for identification of continuous-time systems from samples of input±output data. The two basic approaches may be described as (i) the indirect method, where first a discrete-time model is estimated from the sampled data and then ...

  17. 78 FR 25916 - Authorization of Radiofrequency Equipment

    Science.gov (United States)

    2013-05-03

    ...] Authorization of Radiofrequency Equipment AGENCY: Federal Communications Commission. ACTION: Proposed rule... bodies, and measurement procedures used to determine RF equipment compliance. The Commission believes... Commission is responsible for an equipment authorization program for radiofrequency (RF) devices under part 2...

  18. Radiofrequency initiation and radiofrequency sustainment of laser initiated seeded high pressure plasma

    International Nuclear Information System (INIS)

    Paller, Eric S.; Scharer, John E.; Akhtar, Kamran; Kelly, Kurt; Ding, Guowen

    2001-01-01

    We examine radiofrequency initiation of high pressure(1-70 Torr) inductive plasma discharges in argon, nitrogen, air and organic seed gas mixtures. Millimeter wave interferometry, optical emission and antenna wave impedance measurements for double half-turn helix and helical inductive antennas are used to interpret the rf/plasma coupling, measure the densities in the range of 10 12 cm -3 and analyze the ionization and excited states of the gas mixtures. We have also carried out 193 nm excimer laser initiation of an organic gas seed plasma which is sustained at higher pressures(150 Torr) by radiofrequency coupling at 2.8 kW power levels

  19. Ultrasound-guided radiofrequency ablation of thyroid gland: a preliminary study in dogs

    International Nuclear Information System (INIS)

    Choi, Ji Won; Yoo, Seung Min; Kwak, Seo Hyun

    2005-01-01

    The purpose of this study was to evaluate the possibility of using radiofrequency ablation as the treatment modality for the benign or malignant thyroid nodules in humans. Therefore, we examined the results of using radiofrequency ablation on the thyroid glands in dogs, in respect of the extent of the ablated tissue and the complications. Five dogs (10 lobes of the thyroid glands) were included in this study. US-guided radiofrequency ablation was undertaken with a 10 mm, uncovered 17 gauge cool-tip needle. The power and duration was 20 wattage and 1 minute in five thyroid lobes (group 1) and 20 wattage and 2 minutes in another 5 thyroid lobes (group 2). The ultrasound scans and the pre-and post-enhancement CT scans were undertaken before and immediately after the procedures, and at 24 hours, 72 hours and 1 week later. The US and CT findings of the ablated tissue and complications were evaluated. Blood sampling was done at the pre-procedure time and 1 week later for evaluating the functional status of the thyroid gland. Laryngoscopy was done at the pre-procedure and post-procedure times, and at 24 hours, 72 hours and 1 week later for the evaluation of any recurrent laryngeal nerve palsy. The echo pattern of the ablated thyroid gland at immediately after the radiofrequency ablation appeared as poorly marginated and hyperechoic. On the US obtained 24 hours after radiofrequency ablation, the echo pattern of the ablated thyroid gland was hypoechoic. The maximum diameters after RFA were 9.4 ρ 0.5 mm in group I and 11.4 ρ 0.5 mm in group II. The pre-enhanced CT scan taken at immediately after the radiofrequency ablation showed ill defined hypodense areas in the ablated thyroid gland. Differentiation between the normal and abnormal portions of the thyroid gland was difficult on the contrast enhanced CT scan. Complications induced by radiofrequency ablation were one recurrent laryngeal nerve palsy, two perforations of esophagus and five thickenings of the esophageal wall

  20. Ultrasound-guided radiofrequency ablation of thyroid gland: a preliminary study in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ji Won; Yoo, Seung Min [College of Medicine, Chungang University, Seoul, (Korea, Republic of); Kwak, Seo Hyun [Seoul Veterans Hospital, Seoul (Korea, Republic of)

    2005-07-15

    The purpose of this study was to evaluate the possibility of using radiofrequency ablation as the treatment modality for the benign or malignant thyroid nodules in humans. Therefore, we examined the results of using radiofrequency ablation on the thyroid glands in dogs, in respect of the extent of the ablated tissue and the complications. Five dogs (10 lobes of the thyroid glands) were included in this study. US-guided radiofrequency ablation was undertaken with a 10 mm, uncovered 17 gauge cool-tip needle. The power and duration was 20 wattage and 1 minute in five thyroid lobes (group 1) and 20 wattage and 2 minutes in another 5 thyroid lobes (group 2). The ultrasound scans and the pre-and post-enhancement CT scans were undertaken before and immediately after the procedures, and at 24 hours, 72 hours and 1 week later. The US and CT findings of the ablated tissue and complications were evaluated. Blood sampling was done at the pre-procedure time and 1 week later for evaluating the functional status of the thyroid gland. Laryngoscopy was done at the pre-procedure and post-procedure times, and at 24 hours, 72 hours and 1 week later for the evaluation of any recurrent laryngeal nerve palsy. The echo pattern of the ablated thyroid gland at immediately after the radiofrequency ablation appeared as poorly marginated and hyperechoic. On the US obtained 24 hours after radiofrequency ablation, the echo pattern of the ablated thyroid gland was hypoechoic. The maximum diameters after RFA were 9.4 {rho} 0.5 mm in group I and 11.4 {rho} 0.5 mm in group II. The pre-enhanced CT scan taken at immediately after the radiofrequency ablation showed ill defined hypodense areas in the ablated thyroid gland. Differentiation between the normal and abnormal portions of the thyroid gland was difficult on the contrast enhanced CT scan. Complications induced by radiofrequency ablation were one recurrent laryngeal nerve palsy, two perforations of esophagus and five thickenings of the esophageal

  1. Hyperkalaemia after radiofrequency ablation of hepatocellular carcinoma

    NARCIS (Netherlands)

    Verhoevena, BH; Haagsma, EB; Appeltans, BMG; Slooff, MJH; de Jong, KP

    Radiofrequency ablation of liver tumours is a useful therapy for otherwise unresectable tumours. The complication rate is said to be low. In this case report we describe hyperkalaemia after radiofrequency ablation of a hepatocellular carcinoma in a patient with end-stage renal insufficiency. (C)

  2. Use of Sequenom sample ID Plus® SNP genotyping in identification of FFPE tumor samples.

    Directory of Open Access Journals (Sweden)

    Jessica K Miller

    Full Text Available Short tandem repeat (STR analysis, such as the AmpFlSTR® Identifiler® Plus kit, is a standard, PCR-based human genotyping method used in the field of forensics. Misidentification of cell line and tissue DNA can be costly if not detected early; therefore it is necessary to have quality control measures such as STR profiling in place. A major issue in large-scale research studies involving archival formalin-fixed paraffin embedded (FFPE tissues is that varying levels of DNA degradation can result in failure to correctly identify samples using STR genotyping. PCR amplification of STRs of several hundred base pairs is not always possible when DNA is degraded. The Sample ID Plus® panel from Sequenom allows for human DNA identification and authentication using SNP genotyping. In comparison to lengthy STR amplicons, this multiplexing PCR assay requires amplification of only 76-139 base pairs, and utilizes 47 SNPs to discriminate between individual samples. In this study, we evaluated both STR and SNP genotyping methods of sample identification, with a focus on paired FFPE tumor/normal DNA samples intended for next-generation sequencing (NGS. The ability to successfully validate the identity of FFPE samples can enable cost savings by reducing rework.

  3. Radio-frequency integrated-circuit engineering

    CERN Document Server

    Nguyen, Cam

    2015-01-01

    Radio-Frequency Integrated-Circuit Engineering addresses the theory, analysis and design of passive and active RFIC's using Si-based CMOS and Bi-CMOS technologies, and other non-silicon based technologies. The materials covered are self-contained and presented in such detail that allows readers with only undergraduate electrical engineering knowledge in EM, RF, and circuits to understand and design RFICs. Organized into sixteen chapters, blending analog and microwave engineering, Radio-Frequency Integrated-Circuit Engineering emphasizes the microwave engineering approach for RFICs. Provide

  4. Predictors of Sick Sinus Syndrome in Patients after Successful Radiofrequency Catheter Ablation of Atrial Flutter

    OpenAIRE

    Song, Changho; Jin, Moo-Nyun; Lee, Jung-Hee; Kim, In-Soo; Uhm, Jae-Sun; Pak, Hui-Nam; Lee, Moon-Hyoung; Joung, Boyoung

    2014-01-01

    Purpose The identification of sick sinus syndrome (SSS) in patients with atrial flutter (AFL) is difficult before the termination of AFL. This study investigated the patient characteristics used in predicting a high risk of SSS after AFL ablation. Materials and Methods Out of 339 consecutive patients who had undergone radiofrequency ablation for AFL from 1991 to 2012, 27 (8%) had SSS (SSS group). We compared the clinical characteristics of patients with and without SSS (n=312, no-SSS group). ...

  5. Radiofrequency catheter oblation in atrial flutter

    International Nuclear Information System (INIS)

    Yan Ji; Wang Heping; Xu Jian; Liu Fuyuan; Fan Xizhen; An Chunsheng; Han Xiaoping; Ding Xiaomei; Wang Jiasheng; Gu Tongyuan

    2002-01-01

    Objective: To evaluate the radiofrequency catheter ablation for type I atrial flutter through application of Holo catheter labelling with anatomic imaging localization to ablate the isthmus of IVCTA during complete double-way block. Methods: Eleven cases with type I atrial flutter undergone Holo catheter labelling technique and consecution with conduction time change of coronary venous sinus orifice with-right atrial lower lateral wall pace excitation, were performed with radiofrequency catheter ablation for the isthmus outcoming with complete double-way conduction block. Results: All together 11 cases with 4 of atrial flutter and 7 of sinus rhythm were undergone radiofrequency catheter ablation resulting with double-way conduction block of the isthmus accompanied by prolongation of right atrial conduction time 56.0 ± 2.3 ms and 53.0 ± 4.6 ms respectively. The right atrial excitation appeared to be in clockwise and counter-clockwise of single direction. No recurrence occurred during 3-34 months follow up with only one showing atrial fibrillation. Conclusions: The application of Holo catheter labelling technique with anatomic imaging localization to achieve the double-way conduction block by radiofrequency catheter ablation of TVC-TA isthmus, is a reliable method for treating atrial flutter

  6. Non-surgical radiofrequency facelift.

    Science.gov (United States)

    Narins, David J; Narins, Rhoda S

    2003-10-01

    There has been considerable interest in using non-ablative methods to rejuvenate the skin. The ThermaCool TC (Thermage Inc.) is a radiofrequency (RF) device that has been introduced to induce tightening of the address the problem of skin via a uniform volumetric heating into the deep dermis tightening, resulting in a 'non-surgical facelift'. Radiofrequency produces a uniform volumetric heating into the deep dermis. Twenty treatment areas in 17 patients were treated to evaluate the efficacy and safety of RF treatment to the brow and jowls. The technique was found to produce gradual tightening in most patients, and there were no adverse effects.

  7. RADIO-FREQUENCY MASS SPECTROMETERS AND THEIR APPLICATIONS IN SPACE

    Energy Technology Data Exchange (ETDEWEB)

    Gilmour, Jr., A. S.

    1963-08-15

    The operation of three common radio-frequency mass spectrometers is described, and their performances are compared. Their limitations are pointed out. It is concluded that the quadrupole spectrometer has fewer limitations and is more generally useful in space probes than the other devices. Some present and proposed uses of spectrometers in space are discussed, and the problem of contamination of the atmosphere being sampled by the spectrometer is reviewed. (auth)

  8. High data density and capacity in chipless radiofrequency identification (chipless-RFID) tags based on double-chains of S-shaped split ring resonators (S-SRRs)

    Science.gov (United States)

    Herrojo, Cristian; Mata-Contreras, Javier; Paredes, Ferran; Martín, Ferran

    2017-11-01

    The data density per surface (DPS) is a figure of merit in chipless radiofrequency identification (chipless-RFID) tags. In this paper, it is demonstrated that chipless-RFID tags with high DPS can be implemented by using double-chains of S-shaped split ring resonators (S-SRRs). Tag reading is achieved by near-field coupling between the tag and the reader, a CPW transmission line fed by a harmonic signal tuned to the resonance frequency of the S-SRRs. By transversally displacing the tag over the CPW, the transmission coefficient of the line is modulated by tag motion. This effectively modulates the amplitude of the injected (carrier) signal at the output port of the line, and the identification (ID) code, determined by the presence or absence of S-SRRs at predefined and equidistant positions in the chains, is contained in the envelope function. The DPS is determined by S-SRR dimensions and by the distance between S-SRRs in the chains. However, by using two chains of S-SRRs, the number of bits per unit length that can be accommodated is very high. This chipless-RFID system is of special interest in applications where the reading distance can be sacrificed in favor of data capacity (e.g., security and authentication). Encoding of corporate documents, ballots, exams, etc., by directly printing the proposed tags on the item product to prevent counterfeiting is envisaged.

  9. Development of a new protocol for rapid bacterial identification and susceptibility testing directly from urine samples.

    Science.gov (United States)

    Zboromyrska, Y; Rubio, E; Alejo, I; Vergara, A; Mons, A; Campo, I; Bosch, J; Marco, F; Vila, J

    2016-06-01

    The current gold standard method for the diagnosis of urinary tract infections (UTI) is urine culture that requires 18-48 h for the identification of the causative microorganisms and an additional 24 h until the results of antimicrobial susceptibility testing (AST) are available. The aim of this study was to shorten the time of urine sample processing by a combination of flow cytometry for screening and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for bacterial identification followed by AST directly from urine. The study was divided into two parts. During the first part, 675 urine samples were processed by a flow cytometry device and a cut-off value of bacterial count was determined to select samples for direct identification by MALDI-TOF-MS at ≥5 × 10(6) bacteria/mL. During the second part, 163 of 1029 processed samples reached the cut-off value. The sample preparation protocol for direct identification included two centrifugation and two washing steps. Direct AST was performed by the disc diffusion method if a reliable direct identification was obtained. Direct MALDI-TOF-MS identification was performed in 140 urine samples; 125 of the samples were positive by urine culture, 12 were contaminated and 3 were negative. Reliable direct identification was obtained in 108 (86.4%) of the 125 positive samples. AST was performed in 102 identified samples, and the results were fully concordant with the routine method among 83 monomicrobial infections. In conclusion, the turnaround time of the protocol described to diagnose UTI was about 1 h for microbial identification and 18-24 h for AST. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  10. Active stabilization of ion trap radiofrequency potentials

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, K. G.; Wong-Campos, J. D.; Restelli, A.; Landsman, K. A.; Neyenhuis, B.; Mizrahi, J.; Monroe, C. [Joint Quantum Institute and University of Maryland Department of Physics, College Park, Maryland 20742 (United States)

    2016-05-15

    We actively stabilize the harmonic oscillation frequency of a laser-cooled atomic ion confined in a radiofrequency (rf) Paul trap by sampling and rectifying the high voltage rf applied to the trap electrodes. We are able to stabilize the 1 MHz atomic oscillation frequency to be better than 10 Hz or 10 ppm. This represents a suppression of ambient noise on the rf circuit by 34 dB. This technique could impact the sensitivity of ion trap mass spectrometry and the fidelity of quantum operations in ion trap quantum information applications.

  11. Radiofrequency-thermoablation in malignant liver disease

    International Nuclear Information System (INIS)

    Pichler, L.; Anzboeck, W.; Paertan, G.; Hruby, W.

    2002-01-01

    The clinical application of radiofrequency tumor ablation in primary liver tumors and metastatic liver disease is rapidly growing because this technique has proven to be simple, safe, and effective in first clinical studies. Most of the patients with malignant liver disease are not candidates for surgical resection due localisation or comorbidity, so radiofrequency therapy offers a good alternative for inoperable patients. With this method, high frequency alternating current is delivered to tissue via a needle electrode, the produced heat leads to coagulation necrosis. The largest focus of necrosis that can be induced with the currently available systems is approximately 4-5 cm with a single application. The radiofrequency needle is usually placed with US or CT guidance. For follow up examinations CT and MRI can be used, they proved to be equally accurate in the assessment of treatment response. (orig.) [de

  12. Fractionated bipolar radiofrequency and bipolar radiofrequency potentiated by infrared light for treating striae: A prospective randomized, comparative trial with objective evaluation.

    Science.gov (United States)

    Harmelin, Yona; Boineau, Dominique; Cardot-Leccia, Nathalie; Fontas, Eric; Bahadoran, Philippe; Becker, Anne-Lise; Montaudié, Henri; Castela, Emeline; Perrin, Christophe; Lacour, Jean-Philippe; Passeron, Thierry

    2016-03-01

    Very few treatments for striae are based on prospective randomized trials. The objective of this study was to assess the efficacy of bipolar fractional radiofrequency and bipolar radiofrequency potentiated with infrared light, alone or combined, for treating abdominal stretch marks. Bicentric prospective interventional randomized controlled trial in the department of Dermatology of University Hospital of Nice and Aesthetics Laser Center of Bordeaux, France. Men and women of age 18 years or above, who presented for the treatment of mature or immature abdominal striae were included. The patients' abdomens were divided into four equal quadrants. Bipolar radiofrequency potentiated with infrared light and fractional bipolar radiofrequency were applied, alone or combined, and compared to the remaining untreated quadrant. The main criterion of evaluation was the measurement of depth of striae, using 3D photography at 6 months follow-up. A global assessment was also rated by the physician performing the treatment and by the patients. Histological analysis and confocal laser microscopy were additionally performed. A total of 22 patients were enrolled, and 384 striae were measured. In per protocol analysis mean striae depth was decreased by 21.64%, observed at 6 months follow-up with the combined approach, compared to an increase of 1.73% in the control group (P radiofrequency, combined with bipolar radiofrequency potentiated by infrared light, is an effective treatment of both immature and mature striae of the abdomen. © 2016 Wiley Periodicals, Inc.

  13. Temperature-controlled radiofrequency ablation of cardiac tissue

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, Adrian

    1999-01-01

    BACKGROUND: A variety of basic factors such as electrode tip pressure, flow around the electrode and electrode orientation influence lesion size during radiofrequency ablation, but importantly is dependent on the chosen mode of ablation. However, only little information is available for the frequ......BACKGROUND: A variety of basic factors such as electrode tip pressure, flow around the electrode and electrode orientation influence lesion size during radiofrequency ablation, but importantly is dependent on the chosen mode of ablation. However, only little information is available...... for the frequently used temperature-controlled mode. The purpose of the present experimental study was to evaluate the impact during temperature-controlled radiofrequency ablation of three basic factors regarding electrode-tissue contact and convective cooling on lesion size. METHODS AND RESULTS: In vitro strips......-controlled radiofrequency ablation increased external cooling of the electrode tip due to either flow of the surrounding liquid or poor electrode tissue contact, as exemplified by perpendicular versus parallel electrode orientation, increases lesion size significantly. This is in contrast to the impact of these factors...

  14. Pulsed Radiofrequency Ablation for Treating Sural Neuralgia.

    Science.gov (United States)

    Abd-Elsayed, Alaa; Jackson, Markus; Plovanich, Elizabeth

    2018-01-01

    Sural neuralgia is persistent pain in the distribution of the sural nerve that provides sensation to the lateral posterior corner of the leg, lateral foot, and fifth toe. Sural neuralgia is a rare condition but can be challenging to treat and can cause significant limitation. We present 2 cases of sural neuralgia resistant to conservative management that were effectively treated by pulsed radiofrequency ablation. A 65-year-old female developed sural neuralgia after a foot surgery and failed conservative management. She had successful sural nerve blocks, and pulsed radiofrequency ablation led to an 80% improvement in her pain. A 33-year-old female presented with sural neuralgia secondary to two falls. The patient had tried several conservative modalities with no success. We performed diagnostic blocks and pulsed radiofrequency ablation, and the patient reported 80% improvement in her pain. Pulsed radiofrequency ablation may be a safe and effective treatment for patients with sural neuralgia that does not respond to conservative therapy. However, studies are needed to elucidate its effectiveness and safety profile.

  15. Application of digital sampling techniques to particle identification

    International Nuclear Information System (INIS)

    Bardelli, L.; Poggi, G.; Bini, M.; Carraresi, L.; Pasquali, G.; Taccetti, N.

    2003-01-01

    An application of digital sampling techniques is presented which can greatly simplify experiments involving sub-nanosecond time-mark determinations and energy measurements with nuclear detectors, used for Pulse Shape Analysis and Time of Flight measurements in heavy ion experiments. In this work a 100 M Sample/s, 12 bit analog to digital converter has been used: examples of this technique applied to Silicon and CsI(Tl) detectors in heavy-ions experiments involving particle identification via Pulse Shape analysis and Time of Flight measurements are presented. The system is suited for applications to large detector arrays and to different kinds of detectors. Some preliminary results regarding the simulation of current signals in Silicon detectors are also discussed. (authors)

  16. The radiofrequency frontier: a review of radiofrequency and combined radiofrequency pulsed-light technology in aesthetic medicine.

    Science.gov (United States)

    Sadick, Neil; Sorhaindo, Lian

    2005-05-01

    Radiofrequency (RF) and combined RF light source technologies have established themselves as safe and effective treatment modalities for several dermatologic procedures, including skin tightening, hair and leg vein removal, acne scarring, skin rejuvenation, and wrinkle reduction. This article reviews the technology, clinical applications, and recent advances of RF and combined RF light/laser source technologies in aesthetic medicine.

  17. Treatment of acne vulgaris with fractional radiofrequency microneedling.

    Science.gov (United States)

    Kim, Sang Tae; Lee, Kang Hoon; Sim, Hyung Jun; Suh, Kee Suck; Jang, Min Soo

    2014-07-01

    Fractional radiofrequency microneedling is a novel radiofrequency technique that uses insulated microneedles to deliver energy to the deep dermis at the point of penetration without destruction of the epidermis. It has been used for the treatment of various dermatological conditions including wrinkles, atrophic scars and hypertrophic scars. There have been few studies evaluating the efficacy of fractional radiofrequency microneedling in the treatment of acne, and none measuring objective parameters like the number of inflammatory and non-inflammatory acne lesions or sebum excretion levels. The safety and efficacy of fractional radiofrequency microneedling in the treatment of acne vulgaris was investigated. In a prospective clinical trial, 25 patients with moderate to severe acne were treated with fractional radiofrequency microneedling. The procedure was carried out three times at 1-month intervals. Acne lesion count, subjective satisfaction score, sebum excretion level and adverse effects were assessed at baseline and at 4, 8 and 12 weeks after the first treatment as well as 4, 8 and 12 weeks after the last treatment. Number of acne lesions (inflammatory and non-inflammatory) decreased. Sebum excretion and subjective satisfaction were more favorable at every time point compared with the baseline values (P acne vulgaris. © 2014 Japanese Dermatological Association.

  18. Radiofrequency amplifier based on a DC superconducting quantum interference device

    International Nuclear Information System (INIS)

    Martinis, J.M.; Hilbert, C.; Clarke, J.

    1986-01-01

    A method is described of amplifying a radiofrequency signal consisting of: disposing a single symmetrically biased dc SQUID and an input coil within a superconducting shield, the dc SQUID having a superconducting ring interrupted by two shunted Josephson junctions, and the input coil being inductively coupled solely to the ring of the single SQUID, establishing a constant magnetic flux threading the SQUID ring, applying the radiofrequency signal to the input coil from outside of the superconducting shield, obtaining an amplified radiofrequency signal solely from across the ring of the single SQUID, transmitting the amplified radiofrequency signal from across the SQUID ring to the outside of the superconducting shield

  19. New resonant circuits for the ISOLTRAP radiofrequency quadrupole trap

    CERN Document Server

    SENECAL, Pierre

    2015-01-01

    This report describes my work during my Summer Student Program. My main project was building and testing a resonance-circuit box for a radio-frequency power supply used with the radio-frequency cooler and buncher.

  20. Evaluation of cellular effects of pulsed and continuous wave radiofrequency radiation

    International Nuclear Information System (INIS)

    Pavicic, Ivan; Trosic, Ivancica

    2008-01-01

    Full text: In less than twenty years, the mobile telephone has gone from being rare, expensive equipment of the business elite to a pervasive, low-cost personal item. Since the introduction of mobile phones, concerns have been raised about the potential detrimental impacts on living beings from regular use. The first 'modern' network technology on second generation cellular technology was launched in 1991 in Finland on the Global System for Mobile Communications (GSM) standard. This study evaluates cellular effects of, both, continuous (CW) and pulsed GSM modulated waves (PW). Continuous cell culture of Chinese hamster lung cells, line V79, was used in this study. Cell growth and colony forming ability (CFA) was analyzed after 1, 2 and 3 hours of exposure to the both frequency fields, 935 MHz CW and 915 MHz PW. Selected frequency fields were generated inside gigahertz transversal electromagnetic mode cell (GTEM) equipped with the signal generators. Hewlett Packard HP8657A signal generator was used to generate CW 935 MHz frequency field. Anritzu MS2711B spectrum analyzer with tracking generator and Micro devices RF 3146 power amplifier module generated PW radiofrequency field of 915 MHz. Averaged specific absorption rate (SAR) belonging to the CW 935 MHz frequency field was calculated to be 0.12 W/kg, and for GSM modulated 915 MHz field was 0.23 W/kg. Cell samples were irradiated in triplicate. The sham exposed control cell samples were included in the study. The temperature inside the exposure set-up was recorded in ten-minute intervals through the irradiation treatment. Both, sham-exposed and exposed cell samples were kept in the same condition, except in the time of irradiation for experimental samples when signal generator was switched on. To determine cell growth, V79 samples were plated in concentration of 1x10 4 cells/mL. Cells were maintained in the standard laboratory conditions, which are humidified atmosphere, 37 C degrees, and 5% CO 2 . Cell

  1. Radiofrequency for the Treatment of Lumbar Radicular Pain: Impact on Surgical Indications.

    Science.gov (United States)

    Trinidad, José Manuel; Carnota, Ana Isabel; Failde, Inmaculada; Torres, Luis Miguel

    2015-01-01

    Study Design. Quasiexperimental study. Objective. To investigate whether radiofrequency treatment can preclude the need for spinal surgery in both the short term and long term. Background. Radiofrequency is commonly used to treat lumbosacral radicular pain. Only few studies have evaluated its effects on surgical indications. Methods. We conducted a quasiexperimental study of 43 patients who had been scheduled for spinal surgery. Radiofrequency was indicated for 25 patients. The primary endpoint was the decision of the patient to reject spinal surgery 1 month and 1 year after treatment (pulsed radiofrequency of dorsal root ganglion, 76%; conventional radiofrequency of the medial branch, 12%; combined technique, 12%). The primary endpoint was the decision of the patient to reject spinal surgery 1 month and 1 year after treatment. In addition, we also evaluated adverse effects, ODI, NRS. Results. We observed after treatment with radiofrequency 80% of patients rejected spinal surgery in the short term and 76% in the long term. We conclude that radiofrequency is a useful treatment strategy that can achieve very similar outcomes to spinal surgery. Patients also reported a very high level of satisfaction (84% satisfied/very satisfied). We also found that optimization of the electrical parameters of the radiofrequency improved the outcome of this technique.

  2. Radiofrequency for the Treatment of Lumbar Radicular Pain: Impact on Surgical Indications

    Directory of Open Access Journals (Sweden)

    José Manuel Trinidad

    2015-01-01

    Full Text Available Study Design. Quasiexperimental study. Objective. To investigate whether radiofrequency treatment can preclude the need for spinal surgery in both the short term and long term. Background. Radiofrequency is commonly used to treat lumbosacral radicular pain. Only few studies have evaluated its effects on surgical indications. Methods. We conducted a quasiexperimental study of 43 patients who had been scheduled for spinal surgery. Radiofrequency was indicated for 25 patients. The primary endpoint was the decision of the patient to reject spinal surgery 1 month and 1 year after treatment (pulsed radiofrequency of dorsal root ganglion, 76%; conventional radiofrequency of the medial branch, 12%; combined technique, 12%. The primary endpoint was the decision of the patient to reject spinal surgery 1 month and 1 year after treatment. In addition, we also evaluated adverse effects, ODI, NRS. Results. We observed after treatment with radiofrequency 80% of patients rejected spinal surgery in the short term and 76% in the long term. We conclude that radiofrequency is a useful treatment strategy that can achieve very similar outcomes to spinal surgery. Patients also reported a very high level of satisfaction (84% satisfied/very satisfied. We also found that optimization of the electrical parameters of the radiofrequency improved the outcome of this technique.

  3. Symplicity multi-electrode radiofrequency renal denervation system feasibility study.

    Science.gov (United States)

    Whitbourn, Robert; Harding, Scott A; Walton, Antony

    2015-05-01

    The aim of this study was to test the safety and performance of the Symplicity™ multi-electrode radio-frequency renal denervation system which was designed to reduce procedure time during renal denervation. The multi-electrode radiofrequency renal denervation system feasibility study is a prospective, non-randomised, open label, feasibility study that enrolled 50 subjects with hypertension. The study utilises a new renal denervation catheter which contains an array of four electrodes mounted in a helical configuration at 90 degrees from each other to deliver radiofrequency energy simultaneously to all four renal artery quadrants for 60 seconds. The protocol specified one renal denervation treatment towards the distal end of each main renal artery with radiofrequency energy delivered for 60 seconds per treatment. Total treatment time for both renal arteries was two minutes. The 12-month change in office systolic blood pressure (SBP) and 24-hour SBP was -19.2±25.2 mmHg, prenal artery stenosis or hypertensive emergencies occurred. The Symplicity multi-electrode radiofrequency renal denervation system was associated with a significant reduction in SBP at 12 months and minimal complications whilst it also reduced procedure time. NCT01699529.

  4. Treatment of Benign Thyroid Nodules: Comparison of Surgery with Radiofrequency Ablation.

    Science.gov (United States)

    Che, Y; Jin, S; Shi, C; Wang, L; Zhang, X; Li, Y; Baek, J H

    2015-07-01

    Nodular goiter is one of the most common benign lesions in thyroid nodule. The main treatment of the disease is still the traditional surgical resection, however there are many problems such as general anesthesia, surgical scar, postoperative thyroid or parathyroid function abnormalities, and high nodules recurrence rate in residual gland. The purpose of this study was to compare the efficacy, safety, and cost-effectiveness of 2 treatment methods, surgery and radiofrequency ablation, for the treatment of benign thyroid nodules. From May 2012 to September 2013, 200 patients with nodular goiters who underwent surgery (group A) and 200 patients treated by radiofrequency ablation (group B) were enrolled in this study. Inclusion criteria were the following: 1) cosmetic problem, 2) nodule-related symptoms, 3) hyperfunctioning nodules related to thyrotoxicosis, and 4) refusal of surgery (for group B). An internally cooled radiofrequency ablation system and an 18-ga internally cooled electrode were used. We compared the 2 groups in terms of efficacy, safety, and cost-effectiveness during a 1-year follow-up. After radiofrequency ablation, the nodule volume decreased significantly from 5.4 to 0.4 mL (P = .002) at the 12-month follow-up. The incidence of complications was significantly higher from surgery than from radiofrequency ablation (6.0% versus 1.0%, P = .002). Hypothyroidism was detected in 71.5% of patients after surgery but in none following radiofrequency ablation. The rate of residual nodules (11.9% versus 2.9%, P = .004) and hospitalization days was significantly greater after surgery (6.6 versus 2.1 days, P radiofrequency ablation are both effective treatments of nodular goiter. Compared with surgery, the advantages of radiofrequency ablation include fewer complications, preservation of thyroid function, and fewer hospitalization days. Therefore, radiofrequency ablation should be considered a first-line treatment for benign thyroid nodules. © 2015 by American

  5. Identification of unknown sample using NAA, EDXRF, XRD techniques

    International Nuclear Information System (INIS)

    Dalvi, Aditi A.; Swain, K.K.; Chavan, Trupti; Remya Devi, P.S.; Wagh, D.N.; Verma, R.

    2015-01-01

    Analytical Chemistry Division (ACD), Bhabha Atomic Research Centre (BARC) receives samples from law enforcement agencies such as Directorate of Revenue Intelligence, Customs for analysis. Five unknown grey powdered samples were received for identification and were suspected to be Iridium (Ir). Identification of unknown sample is always a challenging task and suitable analytical techniques have to be judiciously utilized for arriving at the conclusion. Qualitative analysis was carried out using Jordan Valley, EX-3600 M Energy dispersive X-ray fluorescence (EDXRF) spectrometer at ACD, BARC. A SLP series LEO Si (Li) detector (active area: 30 mm 2 ; thickness: 3.5 mm; resolution: 140 eV at 5.9 keV of Mn K X-ray) was used during the measurement and only characteristic X-rays of Ir (Lα: 9.17 keV and Lβ: 10.70 keV) was seen in the X-ray spectrum. X-ray diffraction (XRD) measurement results indicated that the Ir was in the form of metal. To confirm the XRD data, neutron activation analysis (NAA) was carried out by irradiating samples and elemental standards (as comparator) in graphite reflector position of Advanced Heavy Water Reactor Critical Facility (AHWR CF) reactor, BARC, Mumbai. After suitable decay period, gamma activity measurements were carried out using 45% HPGe detector coupled to 8 k multi channel analyzer. Characteristic gamma line at 328.4 keV of the activation product 194 Ir was used for quantification of iridium and relative method of NAA was used for concentration calculations. NAA results confirmed that all the samples were Iridium metal. (author)

  6. Heat Sink Effect on Tumor Ablation Characteristics as Observed in Monopolar Radiofrequency, Bipolar Radiofrequency, and Microwave, Using Ex Vivo Calf Liver Model

    Science.gov (United States)

    Pillai, Krishna; Akhter, Javid; Chua, Terence C.; Shehata, Mena; Alzahrani, Nayef; Al-Alem, Issan; Morris, David L.

    2015-01-01

    Abstract Thermal ablation of liver tumors near large blood vessels is affected by the cooling effect of blood flow, leading to incomplete ablation. Hence, we conducted a comparative investigation of heat sink effect in monopolar (MP) and bipolar (BP) radiofrequency ablation (RFA), and microwave (MW) ablation devices. With a perfused calf liver, the ablative performances (volume, mass, density, dimensions), with and without heat sink, were measured. Heat sink was present when the ablative tip of the probes were 8.0 mm close to a major hepatic vein and absent when >30 mm away. Temperatures (T1 and T2) on either side of the hepatic vein near the tip of the probes, heating probe temperature (T3), outlet perfusate temperature (T4), and ablation time were monitored. With or without heat sink, BP radiofrequency ablated a larger volume and mass, compared with MP RFA or MW ablation, with latter device producing the highest density of tissue ablated. MW ablation produced an ellipsoidal shape while radiofrequency devices produced spheres. Percentage heat sink effect in Bipolar radiofrequency : Mono-polar radiofrequency : Microwave was (Volume) 33:41:22; (mass) 23:56:34; (density) 9.0:26:18; and (relative elipscity) 5.8:12.9:1.3, indicating that BP and MW devices were less affected. Percentage heat sink effect on time (minutes) to reach maximum temperature (W) = 13.28:9.2:29.8; time at maximum temperature (X) is 87:66:16.66; temperature difference (Y) between the thermal probes (T3) and the temperature (T1 + T2)/2 on either side of the hepatic vessel was 100:87:20; and temperature difference between the (T1 + T2)/2 and temperature of outlet circulating solution (T4), Z was 20.33:30.23:37.5. MW and BP radiofrequencies were less affected by heat sink while MP RFA was the most affected. With a single ablation, BP radiofrequency ablated a larger volume and mass regardless of heat sink. PMID:25738477

  7. Fentanyl Iontophoretic Transdermal System (IONSYS(®)) can be Safely used in the Hospital Environment with X-Rays, Computerized Tomography and Radiofrequency Identification Devices.

    Science.gov (United States)

    Lemke, John; Sardariani, Edmond; Phipps, Joseph Bradley; Patel, Niki; Itri, Loretta M; Caravelli, James; Viscusi, Eugene R

    2016-09-01

    Fentanyl iontophoretic transdermal system (fentanyl ITS, IONSYS(®)) is a patient-controlled analgesia system used for the management of acute postoperative pain, designed to be utilized in a hospital setting. The objective of the two studies was to determine if fentanyl ITS could be safely used with X-rays, computerized tomography (CT) scans and radiofrequency identification (RFID) devices. The ITS system has two components: controller and drug unit; the studies utilized ITS systems without fentanyl, referred to as the ITS Placebo system. The first study evaluated the effect of X-radiation on the operation of an ITS Placebo system. Five ITS Placebo systems were exposed to X-rays (20 and 200 mSv total radiation dose-the 200 mSv radiation dose represents a tenfold higher exposure than in clinical practice) while operating in the Ready Mode and five were exposed while operating in the Dose Mode. The second study evaluated the effect of RFID (worst-case scenario of direct contact with an RFID transmitter) on the operation of an ITS Placebo system. During these tests, observations of the user interface and measurements of output voltage confirmed proper function throughout all operational modes (Ready Mode, Dose Mode, End-of-Use Mode, and End-of-Life Mode). The ITS Placebo system met all specifications and no functional anomalies were observed during and following X-ray exposure at two radiation dose levels or exposure at six different combinations of RFID frequencies and field strengths. The performance of the ITS system was unaffected by X-ray exposure levels well beyond those associated with diagnostic X-rays and CT scans, and by exposure to radiofrequency field strengths typically generated by RFID devices. These results provide added confidence to clinicians that the fentanyl ITS system does not need to be removed during diagnostic X-rays and CT scans and can also be utilized in close proximity to RFID devices. The studies and writing of this manuscript were

  8. Occupational exposure to radiofrequency fields in antenna towers

    International Nuclear Information System (INIS)

    Alanko, T.; Hietanen, M.

    2007-01-01

    Exposure of workers to radiofrequency fields was assessed in two medium-sized antenna towers. Towers had transmitting antennas from different networks, e.g. mobile phone networks, radio and digital TV sub-stations and amateur radio. The levels of radiofrequency fields were measured close to the ladders of the towers. All measured values were below ICNIRP occupational reference levels. (authors)

  9. Radiofrequency ablation of liver tumors (II): clinical application and outcomes.

    Science.gov (United States)

    Vanagas, Tomas; Gulbinas, Antanas; Pundzius, Juozas; Barauskas, Giedrius

    2010-01-01

    Radiofrequency ablation is one of the alternatives in the management of liver tumors, especially in patients who are not candidates for surgery. The aim of this article is to review applicability of radiofrequency ablation achieving complete tumor destruction, utility of imaging techniques for patients' follow-up, indications for local ablative procedures, procedure-associated morbidity and mortality, and long-term results in patients with different tumors. The success of local thermal ablation consists in creating adequate volumes of tissue destruction with adequate "clear margin," depending on improved delivery of radiofrequency energy and modulated tissue biophysiology. Different volumes of coagulation necrosis are achieved applying different types of electrodes, pulsing energy sources, utilizing sophisticated ablation schemes. Some additional methods are used to increase the overall deposition of energy through alterations in tissue electrical conductivity, to improve heat retention within the tissue, and to modulate tolerance of tumor tissue to hyperthermia. Contrast-enhanced computed tomography, magnetic resonance imaging, ultrasound or positron emission tomography are applied to control the effectiveness of radiofrequency ablation. The long-term results of radiofrequency ablation are controversial.

  10. 77 FR 43535 - Grantee Codes for Certified Radiofrequency Equipment

    Science.gov (United States)

    2012-07-25

    ... FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 2 [FCC 12-60] Grantee Codes for Certified Radiofrequency Equipment AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: This document... authorization program for radiofrequency (RF) devices under part 2 of its rules. This program is one of the...

  11. Clinical application and developmental trend of radiofrequency ablation technology

    International Nuclear Information System (INIS)

    Chen Dongfeng

    2009-01-01

    For recent two decades, radiofrequency ablation technology has made great progress in the field of the treatment for neoplasm. At the very beginning, radiofrequency ablation was adopted in treating the hepatic carcinoma, and since then it has been gradually practiced in treating malignancies of lung, bone, kidney, breast, prostate and other solid tumors. Statistical report of the year 2008 has indicated that in the aspect of similar therapeutic measures radiofrequency ablation therapy for tumors holds a 9% market share. Moreover, in the coming years the clinical use of this kind of therapy for tumors will be steadily increasing by 13% every year. (authors)

  12. Sample Preparation and Identification of Biological, Chemical and Mid-Spectrum Agents

    National Research Council Canada - National Science Library

    Hancock, J. R; Dragon, D. C

    2005-01-01

    A general survey of sample preparation and identification techniques for biological, chemical and mid-spectrum agents was conducted as part of Canada's contribution to a joint NATO Allied Engineering Publication (AEP) handbook...

  13. Direct measurement of the lethal isotherm for radiofrequency ablation of myocardial tissue.

    Science.gov (United States)

    Wood, Mark; Goldberg, Scott; Lau, Melissa; Goel, Aneesh; Alexander, Daniel; Han, Frederick; Feinstein, Shawn

    2011-06-01

    The lethal isotherm for radiofrequency catheter ablation of cardiac myocardium is widely accepted to be 50°C, but this has not been directly measured. The purpose of this study was to directly measure the tissue temperature at the edge of radiofrequency lesions in real time using infrared thermal imaging. Fifteen radiofrequency lesions of 6 to 240 seconds in duration were applied to the left ventricular surface of isolated perfused pig hearts. At the end of radiofrequency delivery, a thermal image of the tissue surface was acquired with an infrared camera. The lesion was then stained and an optical image of the lesion was obtained. The thermal and optical images were electronically merged to allow determination of the tissue temperature at the edge of the lesion at the end of radiofrequency delivery. By adjusting the temperature overlay display to conform with the edge of the radiofrequency lesion, the lethal isotherm was measured to be 60.6°C (interquartile ranges, 59.7° to 62.4°C; range, 58.1° to 64.2°C). The areas encompassed by the lesion border in the optical image and the lethal isotherm in the thermal image were statistically similar and highly correlated (Spearman ρ=0.99, Pradiofrequency delivery or to lesion size (both P>0.64). The areas circumscribed by 50°C isotherms were significantly larger than the areas of the lesions on optical imaging (P=0.002). By direct measurement, the lethal isotherm for cardiac myocardium is near 61°C for radiofrequency energy deliveries radiofrequency ablation is important to clinical practice as well as mathematical modeling of radiofrequency lesions.

  14. Level of Radiofrequency (RF) Radiations from GSM Base Stations ...

    African Journals Online (AJOL)

    Levels of radiofrequency radiations around two global systems for mobile communication (GSM) base stations located in the vicinity of a residential quarter and workplace complex were measured. The effects of the radiofrequency radiations on albino mice placed in exposure cages and located around the base stations ...

  15. Radiofrequency ablation of osteoid osteomas: five years experience.

    Science.gov (United States)

    Papathanassiou, Zafiria G; Petsas, Theodore; Papachristou, Dionysios; Megas, Panagiotis

    2011-12-01

    The purpose of this study is to retrospectively evaluate the efficacy of radiofrequency ablation as a curative treatment method for benign bone tumours. Twenty-nine osteoid osteomas were treated with radiofrequency ablation. Primary success rate was 89.6% and total secondary success rate was 93.1%. Mean clinical follow-up period was 26.7 months (range: 6-63 months). Statistical analysis of 25 cases of osteoid osteomas with CT follow-up revealed that post-treatment re-ossification does not correlate with clinical outcome (p = 0.14) but is strongly correlated with long-term (> or = 12 months) CT follow-up (p = 0.014). Percutaneous radiofrequency ablation was found to be an effective and safe treatment for osteoid osteomas. CT findings cannot solely differentiate between treatment successes and failures.

  16. Interactions between radiofrequency signals and living organisms

    International Nuclear Information System (INIS)

    Boudin, F.; Hours, M.; Lacronique, J.F.; Conil, E.; Hadjem, A.; El Habachi, A.; Wiart, K.; Mann, S.; Kundi, M.; Marc-Vergnes, J.P.; Roosli, M.; Mohler, E.; Frei, P.; Davis, Ch.C.; Balzano, Q.; Ait-Aissa, S.; Billaudel, B.; Poulletier De Gannes, F.; Hurtier, A.; Haro, E.; Taxile, M.; Veyret, B.; Lagroye, I.; Ait-Aissa, S.; Poulletier De Gannes, F.; Athane, A.; Veyret, B.; Lagroye, I.; Yardin, C.; Perrin, A.; Freire, M.; Bachelet, Ch.; Collin, A.; Pla, S.; Debouzy, J.C.; Leveque, Ph.; Van Nierop, L.E.; Huss, A.; Roosli, M.; Egger, M.; Calvez, M.; Salomon, D.

    2010-01-01

    This dossier is composed of 13 articles dealing with the interactions between radio-frequencies and living organisms. It is an overview of various scientific approaches to the field and is of interest for all citizens as the use of mobile phones is widely spread. In the first article it is shown how a model has been built to assess the distribution of the whole body exposure of the population. The second article reviews the state of the art in personal exposure measurements at radio-frequencies. The third article shows that the knowledge of the mechanism of action by which exposure increases the risk of health hazards is necessary. The fourth article shows that individual neuro-psychic factors take a prominent but maybe not unique, part in electromagnetic hypersensitivity. The fifth article shows that no evidence was found to link health disturbances of electromagnetic hypersensitive individuals with radiofrequency exposure. The sixth article shows that the wireless phone is not an athermal hazard to the brain. The seventh article shows that the in utero and post-natal exposure to Wi-Fi does not damage the brains of young rats. The eighth article concludes that recent studies provide no convincing proof of deleterious effects of radiofrequency exposure on the integrity of the blood-brain barrier for specific absorption rates up to 6 W/kg. The ninth article shows that no co-genotoxic effect of radiofrequency was found at levels of exposure that did not induce heating. The tenth article confirms that industry-sponsored studies were least likely to report results suggesting effects. The last article shows that general practitioners are increasingly questioned by their patients about the issue of electromagnetic waves. (A.C.)

  17. Radio frequency identification of animals, the quality of products in the field.

    NARCIS (Netherlands)

    Hogewerf, P.H.

    2012-01-01

    In several parts of the world livestock animals (sheep, goats and cattle) are identified with radiofrequency identification (RFID) devices. These transponders can be read with handheld and stationary readers. The reading can be performed on the farm, during transport, in the sales yard and in the

  18. Radiofrequency denervation of the hip joint for pain management: case report and literature review.

    Science.gov (United States)

    Gupta, Gaurav; Radhakrishna, Mohan; Etheridge, Paul; Besemann, Markus; Finlayson, Robert J

    2014-01-01

    A 55-year-old male presented with severe pain and functional limitations as a result of left hip osteoarthritis. He had failed multiple treatments while waiting for a hip arthroplasty, including physical therapy, medications, and various intra-articular injections. Thermal radiofrequency lesioning of the obturator and femoral articular branches to the hip joint was offered in the interim. To our knowledge, this is the first report to describe an inferior-lateral approach for lesioning the obturator branch, the clinical application of successive lesions to increase denervation area, and outcomes in a patient receiving a second treatment with previously good results. To discuss relevant and technical factors for this specific case, we reviewed previous literature on hip joint radiofrequency and critically evaluated previous anatomic studies in the context of radiofrequency. The first treatment provided significant benefit for a period of 6 months. A second treatment was employed providing only mild to moderate benefit until his joint replacement surgery 4 months later. Literature review revealed studies of low quality secondary to small sample sizes, patient selection methodology, inclusion of patients with heterogenous etiologies for pain, variable needle placement techniques, and lack of measurement of functional outcomes. Case report and low quality studies in existing literature. Hip joint radiofrequency denervation is a promising avenue for adjunctive treatment of hip pain. Further cadaveric studies are required to clarify a multitude of technical parameters. Once these are well defined, future clinical studies should consider pain, functional, and economic outcomes in their design.

  19. Radiofrequency catheter ablation in the treatment of cardiac arrhythmias (first of two parts)

    International Nuclear Information System (INIS)

    Kou, W.H; Morady, F.

    1997-01-01

    The intravenous radiofrequency catheter inside cardiac s chambers, for inspect signals intracardiac s and to encourage, has been developed as diagnostic tool with the purpose to search arrhythmias physiology and physiopathology.Many energy sources has been used: direct energy, radiofrequency 11-15, laser 6,17, and microwave 18,19. A comparison between radiofrequency and electric energy shock has been described in cardiac arrhythmias treatment, in the present article. It has been tested the radiation biological effects and risk in Wolff Parkinson White patients as well as doctors who handling the fluoroscopy for image during the radiofrequency ablation. Has been described the following techniques: Catheter ablation radiofrequency slow way and fast way

  20. Reconfigurable radio-frequency arbitrary waveforms synthesized in a silicon photonic chip.

    Science.gov (United States)

    Wang, Jian; Shen, Hao; Fan, Li; Wu, Rui; Niu, Ben; Varghese, Leo T; Xuan, Yi; Leaird, Daniel E; Wang, Xi; Gan, Fuwan; Weiner, Andrew M; Qi, Minghao

    2015-01-12

    Photonic methods of radio-frequency waveform generation and processing can provide performance advantages and flexibility over electronic methods due to the ultrawide bandwidth offered by the optical carriers. However, bulk optics implementations suffer from the lack of integration and slow reconfiguration speed. Here we propose an architecture of integrated photonic radio-frequency generation and processing and implement it on a silicon chip fabricated in a semiconductor manufacturing foundry. Our device can generate programmable radio-frequency bursts or continuous waveforms with only the light source, electrical drives/controls and detectors being off-chip. It modulates an individual pulse in a radio-frequency burst within 4 ns, achieving a reconfiguration speed three orders of magnitude faster than thermal tuning. The on-chip optical delay elements offer an integrated approach to accurately manipulating individual radio-frequency waveform features without constraints set by the speed and timing jitter of electronics, and should find applications ranging from high-speed wireless to defence electronics.

  1. Fast beam radiofrequency spectroscopy

    International Nuclear Information System (INIS)

    Pipkin, F.M.

    1983-01-01

    The combination of a fast atom or ion beam derived from a small accelerator with radiofrequency spectroscopy methods provides a powerful method for measuring the fine structure of atomic and molecular systems. The fast beam makes possible measurements in which two separated oscillatory fields are used to obtain resonance lines whose widths are less than the natural line width due to the lifetimes of the states. The separated oscillatory field lines have, in addition, a number of features which make possible measurements with greater precision and less sensitivity to systematic errors. The fast beam also makes accessible multiple photon radiofrequency transitions whose line width is intrinsically narrower than that of the single photon transitions and which offer great potential for high precision measurements. This report focuses on the techniques and their promise. Recent measurements of the fine structure of H and He + are used as illustrations

  2. Semi-blind identification of wideband MIMO channels via stochastic sampling

    OpenAIRE

    Andrieu, Christophe; Piechocki, Robert J.; McGeehan, Joe P.; Armour, Simon M.

    2003-01-01

    In this paper we address the problem of wide-band multiple-input multiple-output (MIMO) channel (multidimensional time invariant FIR filter) identification using Markov chains Monte Carlo methods. Towards this end we develop a novel stochastic sampling technique that produces a sequence of multidimensional channel samples. The method is semi-blind in the sense that it uses a very short training sequence. In such a framework the problem is no longer analytically tractable; hence we resort to s...

  3. Enhanced Radiofrequency Ablation With Magnetically Directed Metallic Nanoparticles.

    Science.gov (United States)

    Nguyen, Duy T; Tzou, Wendy S; Zheng, Lijun; Barham, Waseem; Schuller, Joseph L; Shillinglaw, Benjamin; Quaife, Robert A; Sauer, William H

    2016-05-01

    Remote heating of metal located near a radiofrequency ablation source has been previously demonstrated. Therefore, ablation of cardiac tissue treated with metallic nanoparticles may improve local radiofrequency heating and lead to larger ablation lesions. We sought to evaluate the effect of magnetic nanoparticles on tissue sensitivity to radiofrequency energy. Ablation was performed using an ablation catheter positioned with 10 g of force over prepared ex vivo specimens. Tissue temperatures were measured and lesion volumes were acquired. An in vivo porcine thigh model was used to study systemically delivered magnetically guided iron oxide (FeO) nanoparticles during radiofrequency application. Magnetic resonance imaging and histological staining of ablated tissue were subsequently performed as a part of ablation lesion analysis. Ablation of ex vivo myocardial tissue treated with metallic nanoparticles resulted in significantly larger lesions with greater impedance changes and evidence of increased thermal conductivity within the tissue. Magnet-guided localization of FeO nanoparticles within porcine thigh preps was demonstrated by magnetic resonance imaging and iron staining. Irrigated ablation in the regions with greater FeO, after FeO infusion and magnetic guidance, created larger lesions without a greater incidence of steam pops. Metal nanoparticle infiltration resulted in significantly larger ablation lesions with altered electric and thermal conductivity. In vivo magnetic guidance of FeO nanoparticles allowed for facilitated radiofrequency ablation without direct infiltration into the targeted tissue. Further research is needed to assess the clinical applicability of this ablation strategy using metallic nanoparticles for the treatment of cardiac arrhythmias. © 2016 American Heart Association, Inc.

  4. System Identification of a Non-Uniformly Sampled Multi-Rate System in Aluminium Electrolysis Cells

    Directory of Open Access Journals (Sweden)

    Håkon Viumdal

    2014-07-01

    Full Text Available Standard system identification algorithms are usually designed to generate mathematical models with equidistant sampling instants, that are equal for both input variables and output variables. Unfortunately, real industrial data sets are often disrupted by missing samples, variations of sampling rates in the different variables (also known as multi-rate systems, and intermittent measurements. In industries with varying events based maintenance or manual operational measures, intermittent measurements are performed leading to uneven sampling rates. Such is the case with aluminium smelters, where in addition the materials fed into the cell create even more irregularity in sampling. Both measurements and feeding are mostly manually controlled. A simplified simulation of the metal level in an aluminium electrolysis cell is performed based on mass balance considerations. System identification methods based on Prediction Error Methods (PEM such as Ordinary Least Squares (OLS, and the sub-space method combined Deterministic and Stochastic system identification and Realization (DSR, and its variants are applied to the model of a single electrolysis cell as found in the aluminium smelters. Aliasing phenomena due to large sampling intervals can be crucial in avoiding unsuitable models, but with knowledge about the system dynamics, it is easier to optimize the sampling performance, and hence achieve successful models. The results based on the simulation studies of molten aluminium height in the cells using the various algorithms give results which tally well with the synthetic data sets used. System identification on a smaller data set from a real plant is also implemented in this work. Finally, some concrete suggestions are made for using these models in the smelters.

  5. Radiofrequency cold plasma nitrided carbon steel: Microstructural and micromechanical characterizations

    International Nuclear Information System (INIS)

    Bouanis, F.Z.; Bentiss, F.; Bellayer, S.; Vogt, J.B.; Jama, C.

    2011-01-01

    Highlights: → C38 carbon steel samples were plasma nitrided using a radiofrequency (rf) nitrogen plasma discharge. → RF plasma treatment enables nitriding for non-heated substrates. → The morphological and chemical analyses show the formation of a uniform thickness on the surface of the nitrided C38 steel. → Nitrogen plasma active species diffuse into the samples and lead to the formation of Fe x N. → The increase in microhardness values for nitrided samples with plasma processing time is interpreted by the formation of a thicker nitrided layer on the steel surface. - Abstract: In this work, C38 carbon steel was plasma nitrided using a radiofrequency (rf) nitrogen plasma discharge on non-heated substrates. General characterizations were performed to compare the chemical compositions, the microstructures and hardness of the untreated and plasma treated surfaces. The plasma nitriding was carried out on non-heated substrates at a pressure of 16.8 Pa, using N 2 gas. Surface characterizations before and after N 2 plasma treatment were performed by means of the electron probe microanalysis (EPMA), X-ray photoelectron spectroscopy (XPS) and Vickers microhardness measurements. The morphological and chemical analysis showed the formation of a uniform structure on the surface of the nitrided sample with enrichment in nitrogen when compared to untreated sample. The thickness of the nitride layer formed depends on the treatment time duration and is approximately 14 μm for 10 h of plasma treatment. XPS was employed to obtain chemical-state information of the plasma nitrided steel surfaces. The micromechanical results show that the surface microhardness increases as the plasma-processing time increases to reach, 1487 HV 0.005 at a plasma processing time of 8 h.

  6. Radiofrequency cold plasma nitrided carbon steel: Microstructural and micromechanical characterizations

    Energy Technology Data Exchange (ETDEWEB)

    Bouanis, F.Z. [Universite Lille Nord de France, F-59000 Lille (France); Unite Materiaux et Transformations (UMET), Ingenierie des Systemes Polymeres, CNRS UMR 8207, ENSCL, BP 90108, F-59652 Villeneuve d' Ascq Cedex (France); Bentiss, F. [Laboratoire de Chimie de Coordination et d' Analytique, Faculte des Sciences, Universite Chouaib Doukkali, B.P. 20, M-24000 El Jadida (Morocco); Bellayer, S.; Vogt, J.B. [Universite Lille Nord de France, F-59000 Lille (France); Unite Materiaux et Transformations (UMET), Ingenierie des Systemes Polymeres, CNRS UMR 8207, ENSCL, BP 90108, F-59652 Villeneuve d' Ascq Cedex (France); Jama, C., E-mail: charafeddine.jama@ensc-lille.fr [Universite Lille Nord de France, F-59000 Lille (France); Unite Materiaux et Transformations (UMET), Ingenierie des Systemes Polymeres, CNRS UMR 8207, ENSCL, BP 90108, F-59652 Villeneuve d' Ascq Cedex (France)

    2011-05-16

    Highlights: {yields} C38 carbon steel samples were plasma nitrided using a radiofrequency (rf) nitrogen plasma discharge. {yields} RF plasma treatment enables nitriding for non-heated substrates. {yields} The morphological and chemical analyses show the formation of a uniform thickness on the surface of the nitrided C38 steel. {yields} Nitrogen plasma active species diffuse into the samples and lead to the formation of Fe{sub x}N. {yields} The increase in microhardness values for nitrided samples with plasma processing time is interpreted by the formation of a thicker nitrided layer on the steel surface. - Abstract: In this work, C38 carbon steel was plasma nitrided using a radiofrequency (rf) nitrogen plasma discharge on non-heated substrates. General characterizations were performed to compare the chemical compositions, the microstructures and hardness of the untreated and plasma treated surfaces. The plasma nitriding was carried out on non-heated substrates at a pressure of 16.8 Pa, using N{sub 2} gas. Surface characterizations before and after N{sub 2} plasma treatment were performed by means of the electron probe microanalysis (EPMA), X-ray photoelectron spectroscopy (XPS) and Vickers microhardness measurements. The morphological and chemical analysis showed the formation of a uniform structure on the surface of the nitrided sample with enrichment in nitrogen when compared to untreated sample. The thickness of the nitride layer formed depends on the treatment time duration and is approximately 14 {mu}m for 10 h of plasma treatment. XPS was employed to obtain chemical-state information of the plasma nitrided steel surfaces. The micromechanical results show that the surface microhardness increases as the plasma-processing time increases to reach, 1487 HV{sub 0.005} at a plasma processing time of 8 h.

  7. Percutaneous radiofrequency treatment for refractory anteromedial pain of osteoarthritic knees.

    Science.gov (United States)

    Ikeuchi, Masahiko; Ushida, Takahiro; Izumi, Masashi; Tani, Toshikazu

    2011-04-01

    Although severe knee osteoarthritis with refractory pain is commonly treated surgically, this is often not an option for patients with poor health status or unwillingness to undergo major surgery. We examined the efficacy of radiofrequency application to sensory nerves as a novel alternative treatment for refractory knee pain. This study was an open-label, nonrandomized, and controlled study. Patients complaining of refractory anteromedial knee pain associated with radiological osteoarthritis (moderate or severe) were included. They were assigned to one of two groups: those receiving radiofrequency thermocoagulation (N = 18) or those receiving nerve block (N = 17), depending on the time period that they were referred to the clinic. Radiofrequency current or local anesthetics was applied to the medial retinacular nerve and the infrapatellar branch of the saphenous nerve. Western Ontario McMaster Universities osteoarthritis index score, pain visual analog scale (VAS), and patient's global assessment were assessed with a minimum follow-up of 6 months.   Radiofrequency treatment significantly decreased knee pain as measured by VAS for 12 weeks compared with the control group. In terms of responders, more patients in the RF group responded to the treatment than in the control group. The differences were statistically significant at 4 weeks, 8 weeks, and 12 weeks in pain VAS. Eight patients (44%) treated with radiofrequency rated excellent or good but only three (18%) in the control group rated good, although the difference was not statistically significant. Some patients were able to benefit substantially from radiofrequency treatment. Even if its effective period is limited, radiofrequency application is a promising treatment to alleviate refractory anteromedial knee pain with osteoarthritis. Further experience and technical improvements are needed to establish its role in the management of knee osteoarthritis. Wiley Periodicals, Inc.

  8. Treatment of Refractory Idiopathic Supraorbital Neuralgia Using Percutaneous Pulsed Radiofrequency.

    Science.gov (United States)

    Luo, Fang; Lu, Jingjing; Ji, Nan

    2018-02-26

    No ideal therapeutic method currently exists for refractory idiopathic supraorbital neuralgia patients who do not respond to conservative therapy, including medications and nerve blocks. Pulsed radiofrequency is a neuromodulation technique that does not produce sequelae of nerve damage after treatment. However, the efficacy of percutaneous pulsed radiofrequency for the treatment of refractory idiopathic supraorbital neuralgia is still not clear. The purpose of our study was to evaluate the efficacy and safety of pulsed radiofrequency treatment of the supraorbital nerve for refractory supraorbital neuralgia patients. We prospectively investigated the long-term effects of ultrasound-guided percutaneous pulsed radiofrequency in the treatment of 22 refractory idiopathic supraorbital neuralgia patients. A reduction in the verbal pain numeric rating scale score of more than 50% was used as the standard of effectiveness. The effectiveness rates at different time points within 2 years were calculated. After a single pulsed radiofrequency treatment, the effectiveness rate at 1 and 3 months was 77%, and the rates at 6 months, 1 year, and 2 years were 73%, 64%, and 50%, respectively. Except for a small portion of patients (23%) who experienced mild upper eyelid ecchymosis that gradually disappeared after approximately 2 weeks, no obvious complications were observed. In conclusion, the results of our study demonstrate that for patients with refractory idiopathic supraorbital neuralgia, percutaneous pulsed radiofrequency may be an effective and safe treatment choice. © 2018 World Institute of Pain.

  9. Visualizing radiofrequency-skin interaction using multiphoton microscopy in vivo.

    Science.gov (United States)

    Tsai, Tsung-Hua; Lin, Sung-Jan; Lee, Woan-Ruoh; Wang, Chun-Chin; Hsu, Chih-Ting; Chu, Thomas; Dong, Chen-Yuan

    2012-02-01

    Redundant skin laxity is a major feature of aging. Recently, radiofrequency has been introduced for nonablative tissue tightening by volumetric heating of the deep dermis. Despite the wide range of application based on this therapy, the effect of this technique on tissue and the subsequent tissue remodeling have not been investigated in detail. Our objective is to evaluate the potential of non-linear optics, including multiphoton autofluorescence and second harmonic generation (SHG) microscopy, as a non-invasive imaging modality for the real-time study of radiofrequency-tissue interaction. Electro-optical synergy device (ELOS) was used as the radiofrequency source in this study. The back skin of nude mouse was irradiated with radiofrequency at different passes. We evaluated the effect on skin immediately and 1 month after treatment with multiphoton microscopy. Corresponding histology was performed for comparison. We found that SHG is negatively correlated to radiofrequency passes, which means that collagen structural disruption happens immediately after thermal damage. After 1 month of collagen remodeling, SHG signals increased above baseline, indicating that collagen regeneration has occurred. Our findings may explain mechanism of nonablative skin tightening and were supported by histological examinations. Our work showed that monitoring the dermal heating status of RF and following up the detailed process of tissue reaction can be imaged and quantified with multiphoton microscopy non-invasively in vivo. Copyright © 2011. Published by Elsevier Ireland Ltd.

  10. Effect of radiofrequency on capacitance of low density plasma sheath

    International Nuclear Information System (INIS)

    Carneiro, L.T.; Cunha Rapozo, C. da

    1988-01-01

    It is shown that the influence of induced radiofrequency potential (V RF ) modifies the Bohm theory on ion saturation current, measured with Langmuir probes. The effect of radiofrequency potential on diode type plasma sheath resonance is also investigated. (M.C.K.)

  11. Eye examinations of laser and radiofrequency radiation workers

    International Nuclear Information System (INIS)

    Hocking, B.

    1988-01-01

    There are a growing number of uses of lasers and radiofrequency radiation in industry. Because these radiations may lead to various ocular effects, examinations of the eye are required for laser and radiofrequency workers as part of safe working practices. Various issues concerning these examinations are raised for discussion including: handling personal data, placement criteria, data collection, quality control, control data, the load on service providers, and costs

  12. Bray–Liebhafsky oscillatory reaction in the radiofrequency electromagnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Stanisavljev, Dragomir R., E-mail: dragisa@ffh.bg.ac.rs [Faculty of Physical Chemistry, University of Belgrade, Studentski trg 12-16, P.O. Box 473, 11001 Belgrade (Serbia); Velikić, Zoran [Institute of Physics, University of Belgrade, Pregrevica 118, Zemun (Serbia); Veselinović, Dragan S.; Jacić, Nevena V.; Milenković, Maja C. [Faculty of Physical Chemistry, University of Belgrade, Studentski trg 12-16, P.O. Box 473, 11001 Belgrade (Serbia)

    2014-09-30

    Highlights: • Oscillatory Bray–Liebhafsky reaction is coupled with the radiofrequency radiation. • The effects of radiofrequency field on oscillatory parameters are investigated. • Radiofrequency power of up to the 0.2 W did not produced observable changes. • The explanation related with dissipative and capacitive effects is given. • Open the possibility of investigations of reactive effects on biological systems. - Abstract: Oscillatory Bray–Liebhafsky (BL) reaction is capacitively coupled with the electromagnetic radiation in the frequency range 60–110 MHz. Because of the specific reaction dynamics characterized by several characteristic parameters (induction period, period between chemical oscillations and their amplitude) it served as a good model system for the investigation of the effects of radiofrequent (RF) radiation. RF power of up to 0.2 W did not produce observable changes of the BL reaction parameters in the limit of the experiment reproductivity. Results indicate that, under the given experimental conditions, both dissipative and reactive properties of the solution are not considerably coupled with the RF electrical field.

  13. The Use of Fta Card on Dna Sample Preparation for Molecular of Plant Disease Identification

    OpenAIRE

    Sulistyawati, Purnamila; Rimbawanto, Anto

    2007-01-01

    Accurate and guick identification of pathogen is key to control the spread of plant disesases. Morphological identification is often ineffective because it requires fruit body which often are not presence, rely on characters which may be highly variable within and among species and can be slow and time consuming. Molecular identification of plant disease can overcome most of the shortcomings of morphological identification. Application of FTA Cardn for sample collection is crucial for the su...

  14. Percutaneous radiofrequency ablation for benign nodules of the thyroid gland

    International Nuclear Information System (INIS)

    Baek, Jung Hwan; Jeong, Hyun Jo; Kim, Yoon Suk; Kwak, Min Sook; Chang, Sun Hee; Rhim, Hyun Chul

    2005-01-01

    We wanted to evaluate the efficacy and safety of using ultrasound guided percutaneous radiofrequency ablation for the benign nodules of the thyroid gland. We studied 148 patients with benign thyroid nodules (200 total nodules) that were confirmed histopathologically, and we performed ultrasound guided radiofrequency ablation. The radiofrequency ablation was done 1 to 5 times per one nodule, and follow-up ultrasonography was performed one to nineteen months after the ablation procedures. The physical changes and the decrease of volume of the nodules were evaluated, and the complications related to radiofrequency ablation were observed. The mean initial nodule volume was 0.01-95.61 ml (mean; 6.83 ± SD of 10.63 ml) and the nodule volume after radiofrequency ablation was decreased to 0.00-46.56 ml (mean; 1.83 ± SD of 4.69 ml). The mean volume reduction rate was 73.2%. Reduction of more than 50% was noted in 90% of all cases. For 180 nodules (90%), the decrease was 50% or more, in 20 nodules (10%), the decrease was 49% or less. On gray-scale ultrasonogram obtained after ablation, the echogenicity of the nodules changed to darker, and on the doppler-sonogram, the vascular flow within the nodules disappeared in all cases. Most patients complained pain during or right after the procedure, but the pain was transient and subsided after medication. Two patients developed hoarseness that was improved in 1 week and 2 months, respectively. Sonoguided percutaneous radiofrequency ablation can be one of the treatments for benign nodules of the thyroid gland

  15. Particle identification method in the CsI(Tl) scintillator used for the CHIMERA 4 pi detector

    CERN Document Server

    Alderighi, M; Basssini, R; Berceanu, I; Blicharska, J; Boiano, C; Borderie, B; Bougault, R; Bruno, M; Cali, C; Cardella, G; Cavallaro, S; D'Agostino, M; D'andrea, M; Dayras, R; De Filippo, E; Fichera, F; Geraci, E; Giustolisi, F; Grzeszczuk, A; Guardone, N; Guazzoni, P; Guinet, D; Iacono-Manno, M; Kowalski, S; La Guidara, E; Lanchais, A L; Lanzalone, G; Lanzanò, G; Le Neindre, N; Li, S; Maiolino, C; Majka, Z; Manfredi, G; Nicotra, D; Paduszynski, T; Pagano, A; Papa, M; Petrovici, C M; Piasecki, E; Pirrone, S; Politi, G; Pop, A; Porto, F; Rivet, M F; Rosato, E; Sacca, G; Sechi, G; Simion, V; Sperduto, M L; Steckmeyer, J C; Trifiró, A; Trimarchi, M; Urso, S; Vannini, G; Vigilante, M; Wilczynski, J; Wu, H; Xiao, Z; Zetta, L; Zipper, W

    2002-01-01

    The charged particle identification obtained by the analysis of signals coming from the CsI(Tl) detectors of the CHIMERA 4 pi heavy-ion detector is presented. A simple double-gate integration method, with the use of the cyclotron radiofrequency as reference time, results in low thresholds for isotopic particle identification. The dependence of the identification quality on the gate generation timing is discussed. Isotopic identification of light ions up to Beryllium is clearly seen. For the first time also the identification of Z=5 particles is observed. The identification of neutrons interacting with CsI(Tl) by (n,alpha) and (n,gamma) reactions is also discussed.

  16. Knee cooled radiofrequency vs continuous radiofrequency for genicular neurotomy: preliminary experience - Crio-radiofrequenza vs radiofrequenza continua per neurotomia dei nervi genicolati: esperienza preliminare

    Directory of Open Access Journals (Sweden)

    Alfonso Papa

    2016-09-01

    Full Text Available Radiofrequency neurotomy of genicular nerves has been often used as an efficacious treatment option in all patients suffering from chronic osteoarthritis pain to provide long-term pain relief. After providing informed written consent, 80 patients with severe knee chronic osteoarthritis pain had been enrolled; patients had been divided into two groups (Group C, crioneurolysis, vs Group R, traditional radiofrequency, 40 patients for each group. Pain relief in C group was poorer and with shorter time in duration (median NRS reducing from 8 to 5. Radiofrequency can be considered as an effective, minimally invasive treat­ment for these kinds of conditions, and offers the benefit of being a fast procedure with long-term pain relief.

  17. Mechanisms for enlarging lesion size during irrigated tip radiofrequency ablation

    DEFF Research Database (Denmark)

    Petersen, Helen Høgh; Roman-Gonzalez, Javier; Johnson, Susan B

    2004-01-01

    INTRODUCTION: Irrigated tip radiofrequency ablation of cardiac arrhythmias was developed to increase the size of the radiofrequency-induced lesion, since cooling of the electrode tip allows use of higher power settings. The purpose of this study was to determine if the increased lesion size during...

  18. Paying attention to radiofrequency ablation therapy for neoplasms

    International Nuclear Information System (INIS)

    Wang Zhongming; Li Linsun

    2010-01-01

    Radiofrequency ablation is an effective treatment for malignant tumors. With the development of imaging technique, it has been widely used in treating different kinds of malignant tumors, such as liver cancer, lung cancer, kidney carcinoma, etc. Radiofrequency ablation has a lot of advantages. As a minimally-invasive, safe and effective treatment with less sufferings and fewer complications, this technique has attracted more and more attention of the experts both at home and abroad. (authors)

  19. Radiofrequency for the treatment of skin laxity: mith or truth*

    Science.gov (United States)

    de Araújo, Angélica Rodrigues; Soares, Viviane Pinheiro Campos; da Silva, Fernanda Souza; Moreira, Tatiane da Silva

    2015-01-01

    The nonablative radiofrequency is a procedure commonly used for the treatment of skin laxity from an increase in tissue temperature. The goal is to induce thermal damage to thus stimulate neocollagenesis in deep layers of the skin and subcutaneous tissue. However, many of these devices haven't been tested and their parameters are still not accepted by the scientific community. Because of this, it is necessary to review the literature regarding the physiological effects and parameters for application of radiofrequency and methodological quality and level of evidence of studies. A literature search was performed in MEDLINE, PEDro, SciELO, PubMed, LILACS and CAPES and experimental studies in humans, which used radiofrequency devices as treatment for facial or body laxity, were selected. The results showed that the main physiological effect is to stimulate collagen synthesis. There was no homogeneity between studies in relation to most of the parameters used and the methodological quality of studies and level of evidence for using radiofrequency are low. This fact complicates the determination of effective parameters for clinical use of this device in the treatment of skin laxity. The analyzed studies suggest that radiofrequency is effective, however the physiological mechanisms and the required parameters are not clear in the literature. PMID:26560216

  20. Cervical radiofrequency neurotomy reduces central hyperexcitability and improves neck movement in individuals with chronic whiplash.

    Science.gov (United States)

    Smith, Ashley Dean; Jull, Gwendolen; Schneider, Geoff; Frizzell, Bevan; Hooper, Robert Allen; Sterling, Michele

    2014-01-01

    This study aims to determine if cervical medial branch radiofrequency neurotomy reduces psychophysical indicators of augmented central pain processing and improves motor function in individuals with chronic whiplash symptoms. Prospective observational study of consecutive patients with healthy control comparison. Tertiary spinal intervention centre in Calgary, Alberta, Canada. Fifty-three individuals with chronic whiplash associated disorder symptoms (Grade 2); 30 healthy controls. Measures were made at four time points: two prior to radiofrequency neurotomy, and 1- and 3-months post-radiofrequency neurotomy. Measures included: comprehensive quantitative sensory testing (including brachial plexus provocation test), nociceptive flexion reflex, and motor function (cervical range of movement, superficial neck flexor activity during the craniocervical flexion test). Self-report pain and disability measures were also collected. One-way repeated measures analysis of variance and Friedman's tests were performed to investigate the effect of time on the earlier measures. Differences between the whiplash and healthy control groups were investigated with two-tailed independent samples t-test or Mann-Whitney tests. Following cervical radiofrequency neurotomy, there were significant early (within 1 month) and sustained (3 months) improvements in pain, disability, local and widespread hyperalgesia to pressure and thermal stimuli, nociceptive flexor reflex threshold, and brachial plexus provocation test responses as well as increased neck range of motion (all P  0.13) was measured. Attenuation of psychophysical measures of augmented central pain processing and improved cervical movement imply that these processes are maintained by peripheral nociceptive input. Wiley Periodicals, Inc.

  1. One-year results of the use of endovenous radiofrequency ablation utilising an optimised radiofrequency-induced thermotherapy protocol for the treatment of truncal superficial venous reflux.

    Science.gov (United States)

    Badham, George E; Dos Santos, Scott J; Lloyd, Lucinda Ba; Holdstock, Judy M; Whiteley, Mark S

    2018-06-01

    Background In previous in vitro and ex vivo studies, we have shown increased thermal spread can be achieved with radiofrequency-induced thermotherapy when using a low power and slower, discontinuous pullback. We aimed to determine the clinical success rate of radiofrequency-induced thermotherapy using this optimised protocol for the treatment of superficial venous reflux in truncal veins. Methods Sixty-three patients were treated with radiofrequency-induced thermotherapy using the optimised protocol and were followed up after one year (mean 16.3 months). Thirty-five patients returned for audit, giving a response rate of 56%. Duplex ultrasonography was employed to check for truncal reflux and compared to initial scans. Results In the 35 patients studied, there were 48 legs, with 64 truncal veins treated by radiofrequency-induced thermotherapy (34 great saphenous, 15 small saphenous and 15 anterior accessory saphenous veins). One year post-treatment, complete closure of all previously refluxing truncal veins was demonstrated on ultrasound, giving a success rate of 100%. Conclusions Using a previously reported optimised, low power/slow pullback radiofrequency-induced thermotherapy protocol, we have shown it is possible to achieve a 100% ablation at one year. This compares favourably with results reported at one year post-procedure using the high power/fast pullback protocols that are currently recommended for this device.

  2. Comparison of renal artery, soft tissue, and nerve damage after irrigated versus nonirrigated radiofrequency ablation.

    Science.gov (United States)

    Sakakura, Kenichi; Ladich, Elena; Fuimaono, Kristine; Grunewald, Debby; O'Fallon, Patrick; Spognardi, Anna-Maria; Markham, Peter; Otsuka, Fumiyuki; Yahagi, Kazuyuki; Shen, Kai; Kolodgie, Frank D; Joner, Michael; Virmani, Renu

    2015-01-01

    The long-term efficacy of radiofrequency ablation of renal autonomic nerves has been proven in nonrandomized studies. However, long-term safety of the renal artery (RA) is of concern. The aim of our study was to determine if cooling during radiofrequency ablation preserved the RA while allowing equivalent nerve damage. A total of 9 swine (18 RAs) were included, and allocated to irrigated radiofrequency (n=6 RAs, temperature setting: 50°C), conventional radiofrequency (n=6 RAs, nonirrigated, temperature setting: 65°C), and high-temperature radiofrequency (n=6 RAs, nonirrigated, temperature setting: 90°C) groups. RAs were harvested at 10 days, serially sectioned from proximal to distal including perirenal tissues and examined after paraffin embedding, and staining with hematoxylin-eosin and Movat pentachrome. RAs and periarterial tissue including nerves were semiquantitatively assessed and scored. A total of 660 histological sections from 18 RAs were histologically examined by light microscopy. Arterial medial injury was significantly less in the irrigated radiofrequency group (depth of medial injury, circumferential involvement, and thinning) than that in the conventional radiofrequency group (Pradiofrequency group (Pradiofrequency group and conventional radiofrequency group (P=0.36), there was a trend toward less nerve damage in the irrigated compared with conventional. Compared to conventional radiofrequency, circumferential medial damage in highest-temperature nonirrigated radiofrequency group was significantly greater (Pradiofrequency ablation, and there is a trend toward less nerve damage. © 2014 American Heart Association, Inc.

  3. Electromagnetic field sources in radiofrequency

    International Nuclear Information System (INIS)

    Oliveira, C.; Sebastiao, D.; Ladeira, D.; Antunes, M.; Correia, L.M.

    2010-01-01

    In the scope of the monIT Project, several measurements were made of electromagnetic fields in Portugal. This paper presents an analysis of the sources operating in the radiofrequency range, resulting from 2429 measurements in 466 locations.

  4. RADIOFREQUENCY IDENTIFICATION CURRENT AND PROSPECTIVE SCENARIO

    Directory of Open Access Journals (Sweden)

    Félix Larrañaga

    2010-07-01

    Full Text Available Radio Frequency Identification Technology (RFID that arose from World War II developments has become one of the most attractive management tools to the business environment yet has faced scarce current applicability. This study analyses the opinion of specialists engaged in the industry, trade and logistics management of diverse economic segments with views to presenting an amplified perspective of this technologies current and future behaviour, as well as its inclusion within the corporate environment. The subject matter of choice derives from the author’s personal curiosity, as leveraged by numerous publications that failed to reveal coincidental opinions and operational approaches concerning the use of this technology. This seems to have found ground given the lack of technical knowledge within both the business community and the public in general and, undoubtedly, considering its high implementation costs.  The research, of bibliographical nature, concludes that effectively there are favourable and unfavourable opinions concerning this technology’s application at the surveyed industries and organizations, although most acknowledge its high potential business management efficiency and effectiveness. It is understood that only a favourable evolution of economic activities will promote the necessary investments and drive players into furthering in-depth studies concerning the varied RFID possibilities in addition to analysing the strategic convenience of its application. Key-words:  RFID. Logistics. Strategic Management. Supply Chains.

  5. [Catheter ablation in patients with refractory cardiac arrhythmias with radiofrequency techniques].

    Science.gov (United States)

    de Paola, A A; Balbão, C E; Silva Netto, O; Mendonça, A; Villacorta, H; Vattimo, A C; Souza, I A; Guiguer Júnior, N; Portugal, O P; Martinez Filho, E E

    1993-02-01

    evaluate the efficacy of radiofrequency catheter ablation in patients with refractory cardiac arrhythmias. twenty patients with refractory cardiac arrhythmias were undertaken to electrophysiologic studies for diagnosis and radiofrequency catheter ablation of their reentrant arrhythmias. Ten patients were men and 10 women with ages varying from 13 to 76 years (mean = 42.4 years). Nineteen patients had supraventricular tachyarrhythmias: One patient had atrial tachycardia and 1 atrial fibrillation with rapid ventricular rate, 5 patients had reentrant nodal tachycardia, 12 patients had reentrant atrioventricular tachycardia and 1 patient had right ventricular outflow tract tachycardia. the mean time of the procedure was 4.1 hours. The radiofrequency current energy applied was 40-50 V for 30-40 seconds. Ablation was successful in 18/20 (90%) patients; in 15/18 (83%) of successfully treated patients the same study was done for diagnosis and radiofrequency ablation. One patient had femoral arterial occlusion and was treated with no significant sequelae. During a mean follow-up of 4 months no preexcitation or reentrant tachycardia occurred. the results of our experience with radiofrequency catheter ablation of cardiac arrhythmias suggest that this technique can benefit an important number of patients with cardiac arrhythmias.

  6. Radiofrequency ablation of hepatic metastasis: Results of treatment in forty patients

    Directory of Open Access Journals (Sweden)

    Rath G

    2008-01-01

    Full Text Available Aim: To evaluate the local control of hepatic metastasis with radiofrequency ablation treatment. Materials and Methods: We did a retrospective analysis in 40 patients treated with radiofrequency ablation for hepatic metastasis. The tumors ablated included up to two metastatic liver lesions, with primaries in breast, gastrointestinal tract, cervix, etc. Radiofrequency ablation was performed under general anesthesia in all cases, using ultrasound guidance. Radionics Cool-Tip RF System was used to deliver the treatment. Results: The median age of patients treated was 49 years. There were 13 female and 27 male patients. The median tumor size ablated was 1.5 cm (0.75-4.0 cm. A total of 52 radiofrequency ablation cycles were delivered. Successful ablation was achieved in all patients with hepatic metastasis less than 3 cm in size. Pain was the most common complication seen (75%. One patients developed skin burns. At 2-year follow-up 7.5% of patients had locally recurrent disease. Conclusions: Radiofrequency ablation is a minimally invasive treatment modality. It can be useful in a select group of patients with solitary liver metastasis of less than 3 cm size.

  7. 21 CFR 179.30 - Radiofrequency radiation for the heating of food, including microwave frequencies.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Radiofrequency radiation for the heating of food... PRODUCTION, PROCESSING AND HANDLING OF FOOD Radiation and Radiation Sources § 179.30 Radiofrequency radiation for the heating of food, including microwave frequencies. Radiofrequency radiation, including...

  8. The safety and efficacy of a combined diode laser and bipolar radiofrequency compared with combined infrared light and bipolar radiofrequency for skin rejuvenation

    Directory of Open Access Journals (Sweden)

    Yeon Jin Choi

    2012-01-01

    Full Text Available Background: As the demand for noninvasive procedures for skin rejuvenation is increasing, combined diode laser and radiofrequency and combined infrared and radiofrequency devices have recently emerged. Aim: To compare Polaris WRA TM , a combination device of diode light and RF, and ReFirme ST TM , a combination device of infrared and bipolar RF, in terms of safety and efficacy on skin rejuvenation. Methods: Fourteen Korean volunteers of skin type II-IV, with facial laxity and periorbital rhytids, received three treatments at 3-week intervals with combined diode laser and bipolar radiofrequency (laser fluence 30 J/cm 2 , RF fluence 90 J/cm 3 on the right half of their faces and combined infrared light and bipolar radiofrequency (RF fluence 120 J/cm 3 on the left half of their faces. Clinical photos of front and bilateral sides of the subjects′ faces were taken at baseline and at 6, 9, 12 weeks after the treatment initiation. The investigators′ and the subjects′ global assessments were performed. Results: There is no statistically significant difference in the overall outcome between Polaris WRA TM and Refirme ST TM based on pre- and post-treatment objective measurements. Polaris WRA TM was more effective than Refirme ST TM at reducing wrinkles when therapeutic results of the two appliances were compared based on the patient satisfaction measurements. After the treatment with both instruments, histological increase in the production and rearrangement of collagen fibers at the dermal layer was observed. The density of the collagen fibers was more increased with the Polaris WRA TM -treated facial area than that of Refirme ST TM . Treatment was generally well tolerated, and there was no serious complication. Conclusion: In this study, both the lasers appeared to be safe, and effective methods for treating skin laxity and facial wrinkles. Combined diode laser and radiofrequency was more effective than combined infrared and radiofrequency at

  9. The safety and efficacy of a combined diode laser and bipolar radiofrequency compared with combined infrared light and bipolar radiofrequency for skin rejuvenation.

    Science.gov (United States)

    Choi, Yeon Jin; Lee, Jung Yeon; Ahn, Ji Young; Kim, Myeung Nam; Park, Mi Youn

    2012-01-01

    As the demand for noninvasive procedures for skin rejuvenation is increasing, combined diode laser and radiofrequency and combined infrared and radiofrequency devices have recently emerged. To compare Polaris WRA(TM), a combination device of diode light and RF, and ReFirme ST(TM), a combination device of infrared and bipolar RF, in terms of safety and efficacy on skin rejuvenation. Fourteen Korean volunteers of skin type II-IV, with facial laxity and periorbital rhytids, received three treatments at 3-week intervals with combined diode laser and bipolar radiofrequency (laser fluence 30 J/cm2, RF fluence 90 J/cm3) on the right half of their faces and combined infrared light and bipolar radiofrequency (RF fluence 120 J/cm3) on the left half of their faces. Clinical photos of front and bilateral sides of the subjects' faces were taken at baseline and at 6, 9, 12 weeks after the treatment initiation. The investigators' and the subjects' global assessments were performed. There is no statistically significant difference in the overall outcome between Polaris WRA(TM) and Refirme ST(TM) based on pre- and post-treatment objective measurements. Polaris WRA(TM) was more effective than Refirme ST(TM) at reducing wrinkles when therapeutic results of the two appliances were compared based on the patient satisfaction measurements. After the treatment with both instruments, histological increase in the production and rearrangement of collagen fibers at the dermal layer was observed. The density of the collagen fibers was more increased with the Polaris WRA(TM)-treated facial area than that of Refirme ST(TM). Treatment was generally well tolerated, and there was no serious complication. In this study, both the lasers appeared to be safe, and effective methods for treating skin laxity and facial wrinkles. Combined diode laser and radiofrequency was more effective than combined infrared and radiofrequency at reducing wrinkles and pores when the therapeutic results of both the

  10. 12-month efficacy of a single radiofrequency ablation on autonomously functioning thyroid nodules.

    Science.gov (United States)

    Bernardi, Stella; Stacul, Fulvio; Michelli, Andrea; Giudici, Fabiola; Zuolo, Giulia; de Manzini, Nicolò; Dobrinja, Chiara; Zanconati, Fabrizio; Fabris, Bruno

    2017-09-01

    Radiofrequency ablation has been advocated as an alternative to radioiodine and/or surgery for the treatment of autonomously functioning benign thyroid nodules. However, only a few studies have measured radiofrequency ablation efficacy on autonomously functioning benign thyroid nodules. The aim of this work was to evaluate the 12-month efficacy of a single session of radiofrequency ablation (performed with the moving shot technique) on solitary autonomously functioning benign thyroid nodules. Thirty patients with a single, benign autonomously functioning benign thyroid nodules, who were either unwilling or ineligible to undergo surgery and radioiodine, were treated with radiofrequency ablation between April 2012 and May 2015. All the patients underwent a single radiofrequency ablation, performed with the 18-gauge needle and the moving shot technique. Clinical, laboratory, and ultrasound evaluations were scheduled at baseline, and after 1, 3, 6, and 12 months from the procedure. A single radiofrequency ablation reduced thyroid nodule volume by 51, 63, 69, and 75 % after 1, 3, 6, and 12 months, respectively. This was associated with a significant improvement of local cervical discomfort and cosmetic score. As for thyroid function, 33 % of the patients went into remission after 3 months, 43 % after 6 months, and 50 % after 12 months from the procedure. This study demonstrates that a single radiofrequency ablation allowed us to withdraw anti-thyroid medication in 50 % of the patients, who remained euthyroid afterwards. This study shows that a single radiofrequency ablation was effective in 50 % of patients with autonomously functioning benign thyroid nodules. Patients responded gradually to the treatment. It is possible that longer follow-up studies might show greater response rates.

  11. WORKSHOP: Radiofrequency superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1984-10-15

    The Second Workshop on Radiofrequency Superconductivity was held at CERN from 23-27 July, four years after the first, organized at Karlsruhe. 35 invited talks were presented to the about 80 participants from Australia, Brazil, Europe, Japan and the United States. For the first time, ten Laboratories operating or planning superconducting accelerators for heavy ions participated and shared their experience with the community proposing the use of superconducting accelerating sections for electron accelerators.

  12. WORKSHOP: Radiofrequency superconductivity

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    The Second Workshop on Radiofrequency Superconductivity was held at CERN from 23-27 July, four years after the first, organized at Karlsruhe. 35 invited talks were presented to the about 80 participants from Australia, Brazil, Europe, Japan and the United States. For the first time, ten Laboratories operating or planning superconducting accelerators for heavy ions participated and shared their experience with the community proposing the use of superconducting accelerating sections for electron accelerators

  13. Use of dc Ar microdischarge with nonlocal plasma for identification of metal samples

    Energy Technology Data Exchange (ETDEWEB)

    Kudryavtsev, A. A., E-mail: akud@ak2138.spb.edu [St. Petersburg State University, 7-9 Universitetskaya nab., 199034 St. Petersburg (Russian Federation); Stefanova, M. S.; Pramatarov, P. M. [Institute of Solid State Physics, Bulgarian Academy of Sciences, 72 Tzarigradsko Chaussee Blvd., 1784 Sofia (Bulgaria)

    2015-04-07

    The possibility of using the collisional electron spectroscopy (CES) method for the detection of atoms from metal samples is experimentally verified. The detection and identification of metal atoms from a Pt sample in the nonlocal plasma of short (without positive column) dc Ar microdischarge at intermediate pressures (5–30 Torr) is realized in this work. Cathode sputtering is used for atomization of the metal under analysis. The identification of the analyzed metal is made from the energy spectra of groups of fast nonlocal electrons—characteristic electrons released in the Penning ionization of the Pt atoms by Ar metastable atoms and molecules. The acquisition of the electron energy spectra is performed using an additional electrode—a sensor located at the boundary of the discharge volume. The Pt characteristic Penning electrons form the maxima in the electron energy spectra at the energies of their appearance, which are 2.6 eV and 1.4 eV. From the measured energy of the maxima, identification of the metal atoms is accomplished. The characteristic Ar maxima due to pair collisions between Ar metastable atoms and molecules and super-elastic collisions are also recorded. This study demonstrates the possibility of creating a novel microplasma analyzer for atoms from metal samples.

  14. Bipolar Radiofrequency Facet Ablation of the Lumbar Facet Capsule: An Adjunct to Conventional Radiofrequency Ablation for Pain Management.

    Science.gov (United States)

    Jacobson, Robert E; Palea, Ovidiu; Granville, Michelle

    2017-09-01

    Radiofrequency facet ablation (RFA) has been performed using the same technique for over 50 years. Except for variations in electrode size, tip shape, and change in radiofrequency (RF) stimulation parameters, using standard, pulsed, and cooled RF wavelengths, the target points have remained absolutely unchanged from the original work describing RFA for lumbar pain control. Degenerative changes in the facet joint and capsule are the primary location for the majority of lumbar segmental pathology and pain. Multiple studies show that the degenerated facet joint is richly innervated as a result of the inflammatory overgrowth of the synovium. The primary provocative clinical test to justify an RFA is to perform an injection with local anesthetic into the facet joint and the posterior capsule and confirm pain relief. However, after a positive response, the radiofrequency lesion is made not to the facet joint but to the more proximal fine nerve branches that innervate the joint. The accepted target points for the recurrent sensory branch ignore the characteristic rich innervation of the pathologic lumbar facet capsule and assume that lesioning of these recurrent branches is sufficient to denervate the painful pathologic facet joint. This report describes the additional targets and technical steps for further coagulation points along the posterior capsule of the lumbar facet joint and the physiologic studies of the advantage of the bipolar radiofrequency current in this location. Bipolar RF to the facet capsule is a simple, extra step that easily creates a large thermo-coagulated lesion in this capsule region of the pathologic facet joint. Early studies demonstrate bipolar RF to the facet capsule can provide long-term pain relief when used alone for specific localized facet joint pain, to coagulate lumbar facet cysts to prevent recurrence, and to get more extensive pain control by combining it with traditional lumbar RFA, especially when RFA is repeated.

  15. A New Radiofrequency Ablation Procedure to Treat Sacroiliac Joint Pain.

    Science.gov (United States)

    Cheng, Jianguo; Chen, See Loong; Zimmerman, Nicole; Dalton, Jarrod E; LaSalle, Garret; Rosenquist, Richard

    2016-01-01

    Low back pain may arise from disorders of the sacroiliac joint in up to 30% of patients. Radiofrequency ablation (RFA) of the nerves innervating the sacroiliac joint has been shown to be a safe and efficacious strategy. We aimed to develop a new RFA technique to relieve low back pain secondary to sacroiliac joint disorders. Methodology development with validation through prospective observational non-randomized trial (PONRT). Academic multidisciplinary health care system, Ohio, USA. We devised a guide-block to facilitate accurate placement of multiple electrodes to simultaneously ablate the L5 dorsal ramus and lateral branches of the S1, S2, and S3 dorsal rami. This was achieved by bipolar radiofrequency ablation (b-RFA) to create a strip lesion from the lateral border of the base of the sacral superior articular process (L5-S1 facet joint) to the lateral border of the S3 sacral foramen. We applied this technique in 31 consecutive patients and compared the operating time, x-ray exposure time and dose, and clinical outcomes with patients (n = 62) who have been treated with the cooled radiofrequency technique. Patients' level of pain relief was reported as 80% pain relief at one, 3, 6, and 12 months after the procedure. The relationship between RFA technique and duration of pain relief was evaluated using interval-censored multivariable Cox regression. The new technique allowed reduction of operating time by more than 50%, x-ray exposure time and dose by more than 80%, and cost by more than $1,000 per case. The percent of patients who achieved > 50% pain reduction was significantly higher in the b-RFA group at 3, 6, and 12 months follow-up, compared to the cooled radiofrequency group. No complications were observed in either group. Although the major confounding factors were taken into account in the analysis, use of historical controls does not balance observed and unobserved potential confounding variables between groups so that the reported results are potentially

  16. Cooling system for the IFMIF-EVEDA radiofrequency system

    International Nuclear Information System (INIS)

    Perez Pichel, G. D.

    2012-01-01

    The IFMIF-EVEDA project consists on an accelerator prototype that will be installed at Rokkasho (Japan). Through CIEMAT, that is responsible of the development of many systems and components. Empresarios Agrupados get the responsibility of the detailed design of the cooling system for the radiofrequency system (RF system) that must feed the accelerator. the RF water cooling systems is the water primary circuit that provides the required water flow (with a certain temperature, pressure and water quality) and also dissipates the necessary thermal power of all the radiofrequency system equipment. (Author) 4 refs.

  17. Identification of Forensic Samples via Mitochondrial DNA in the Undergraduate Biochemistry Laboratory

    Science.gov (United States)

    Millard, Julie T.; Pilon, André M.

    2003-04-01

    A recent forensic approach for identification of unknown biological samples is mitochondrial DNA (mtDNA) sequencing. We describe a laboratory exercise suitable for an undergraduate biochemistry course in which the polymerase chain reaction is used to amplify a 440 base pair hypervariable region of human mtDNA from a variety of "crime scene" samples (e.g., teeth, hair, nails, cigarettes, envelope flaps, toothbrushes, and chewing gum). Amplification is verified via agarose gel electrophoresis and then samples are subjected to cycle sequencing. Sequence alignments are made via the program CLUSTAL W, allowing students to compare samples and solve the "crime."

  18. Fraxelated radiofrequency device for acne scars

    Science.gov (United States)

    Rao, Babar K.; Khokher, Sairah

    2012-09-01

    Acne scars can be improved with various treatments such as topical creams, chemical peels, dermal fillers, microdermabrasion, laser, and radiofrequency devices. Some of these treatments especially lasers and deep chemical peels can have significant side effects such as post inflammatory hyperpigmentation in darker skin types. Fraxelated RF Laser devices have been reported to have lower incidence of side effects in all skin phototypes. Nine patients between ages 18 and 35 of various skin phototypes were selected from a private practice and treated with a RF fraxelated device (E-matrix) for acne scars. Outcomes were measured by physician observation, subjective feedback received by patients, and comparison of before and after photographs. In this small group of patients with various skin phototypes, fraxelated radiofrequency device improved acne scars with minimal side effects and downtime.

  19. Arthroscopic surgery using radio-frequency electrocautery

    International Nuclear Information System (INIS)

    Takatsuka, Shigeyuki; Yoshida, Kan; Nakagawa, Kiyomasa; Yamamoto, Etsuhide; Kubota, Yoshiyuki; Narinobou, Masayoshi; Terai, Koichi; Hasegawa, Hiroshi

    2008-01-01

    Arthroscopic surgery using radio-frequency electrocautery was carried out on 23 temporomandibular joints (TMJs) in 13 patients. Because these patients did not respond to conservative therapy, surgery was indicated. Preoperative MRI showed anterior disc displacement without reduction in all patients. Disturbed translation was also recognized in all of the discs and mandibular condyles. Intraoperative arthroscopic examination showed severe fibrous adhesion in the upper joint compartment and disc displacement. Four joints showed perforation between the disc and retrodiscal tissue. Postoperative findings included an increased range of vertical maximal mouth opening and decreased pain on mandibular movement. Analyses of postoperative MRI indicated recovery of disc and condylar translation. These results suggested that the introduction of arthroscopic surgery using radiofrequency electrocautery would significantly reduce the number of patients with osteoarthritic TMJ disorders. (author)

  20. Transurethral radiofrequency collagen denaturation for the treatment of women with urinary incontinence.

    Science.gov (United States)

    Kang, Diana; Han, Julia; Neuberger, Molly M; Moy, M Louis; Wallace, Sheila A; Alonso-Coello, Pablo; Dahm, Philipp

    2015-03-18

    Transurethral radiofrequency collagen denaturation is a relatively novel, minimally invasive device-based intervention used to treat individuals with urinary incontinence (UI). No systematic review of the evidence supporting its use has been published to date. To evaluate the efficacy of transurethral radiofrequency collagen denaturation, compared with other interventions, in the treatment of women with UI.Review authors sought to compare the following.• Transurethral radiofrequency collagen denaturation versus no treatment/sham treatment.• Transurethral radiofrequency collagen denaturation versus conservative physical treatment.• Transurethral radiofrequency collagen denaturation versus mechanical devices (pessaries for UI).• Transurethral radiofrequency collagen denaturation versus drug treatment.• Transurethral radiofrequency collagen denaturation versus injectable treatment for UI.• Transurethral radiofrequency collagen denaturation versus other surgery for UI. We conducted a systematic search of the Cochrane Incontinence Group Specialised Register (searched 19 December 2014), EMBASE and EMBASE Classic (January 1947 to 2014 Week 50), Google Scholar and three trials registries in December 2014, along with reference checking. We sought to identify unpublished studies by handsearching abstracts of major gynaecology and urology meetings, and by contacting experts in the field and the device manufacturer. Randomised and quasi-randomised trials of transurethral radiofrequency collagen denaturation versus no treatment/sham treatment, conservative physical treatment, mechanical devices, drug treatment, injectable treatment for UI or other surgery for UI in women were eligible. We screened search results and selected eligible studies for inclusion. We assessed risk of bias and analysed dichotomous variables as risk ratios (RRs) with 95% confidence intervals (CIs) and continuous variables as mean differences (MDs) with 95% CIs. We rated the quality of

  1. Analysis of low-dimensional radio-frequency impedance-based cardio-synchronous waveforms for biometric authentication.

    Science.gov (United States)

    Venugopalan, Shreyas; Savvides, Marios; Griofa, Marc O; Cohen, Ken

    2014-08-01

    Over the past two decades, there have been a lot of advances in the field of pattern analyses for biomedical signals, which have helped in both medical diagnoses and in furthering our understanding of the human body. A relatively recent area of interest is the utility of biomedical signals in the field of biometrics, i.e., for user identification. Seminal work in this domain has already been done using electrocardiograph (ECG) signals. In this paper, we discuss our ongoing work in using a relatively recent modality of biomedical signals-a cardio-synchronous waveform measured using a Radio-Frequency Impedance-Interrogation (RFII) device for the purpose of user identification. Compared to an ECG setup, this device is noninvasive and measurements can be obtained easily and quickly. Here, we discuss the feasibility of reducing the dimensions of these signals by projecting onto various subspaces while still preserving interuser discriminating information. We compare the classification performance using classical dimensionality reduction methods such as principal component analysis (PCA), independent component analysis (ICA), random projections, with more recent techniques such as K-SVD-based dictionary learning. We also report the reconstruction accuracies in these subspaces. Our results show that the dimensionality of the measured signals can be reduced by 60 fold while maintaining high user identification rates.

  2. Ion collection from laser-induced plasma by applying radio-frequency voltage

    International Nuclear Information System (INIS)

    Shibata, Takemasa; Ogura, Koichi

    1995-01-01

    Ions were collected on the electrodes from a laser resonance photoionized plasma by applying 1.8MHz radio-frequency voltage to the electrode. It was demonstrated that the ions are collected in a shorter time at the same kinetic energy of the collected ions compared with ion collection by applying DC voltage to the electrode. A simple one-dimensional model was extended for prediction of ion collection times in the cases of applications of not only the DC voltage but also the radio-frequency voltage. The ion collection times estimated using the simple one-dimensional model agreed with experimental values in both cases of DC and radio-frequency voltages. (author)

  3. Effect of Radiofrequency Endometrial Ablation on Dysmenorrhea.

    Science.gov (United States)

    Wyatt, Sabrina N; Banahan, Taylor; Tang, Ying; Nadendla, Kavita; Szychowski, Jeff M; Jenkins, Todd R

    To examine rates of dysmenorrhea after radiofrequency endometrial ablation in patients with and without known dysmenorrhea symptoms prior to the procedure in a diverse population. Retrospective cohort study (Canadian Task Force classification II-2). Academic gynecology practice. A total of 307 women underwent endometrial ablation between 2007 and 2013 at our institution. Patients who had preoperative and postoperative pain symptom assessments as well as a description of pain timing recorded were included in our analysis. Exclusion criteria were age dysmenorrhea was evaluated. Demographic information and other outcome variables were used to evaluate factors associated with resolution of dysmenorrhea. A total of 307 patients who underwent radiofrequency endometrial ablation were identified. After exclusions, 296 charts were examined, and 144 patients met our enrollment criteria. The mean age of the study cohort was 45.4 ± 6.2 years; 57 patients (40%) were African American, 16 (11%) had a body mass index (BMI) > 40, and 41 (29%) were of normal weight. Preoperative dysmenorrhea was reported by 100 patients (69%); 48 of these patients (48%) experienced resolution of symptoms postoperatively. Only 3 of the 44 patients (7%) without preoperative dysmenorrhea reported new-onset dysmenorrhea postoperatively. Significantly fewer patients had dysmenorrhea after compared to before radiofrequency ablation (55 of 144 [38%] vs 100 of 144 [69%]; p dysmenorrhea after ablation was associated with reduction in bleeding volume (p = .048) but not with a reduction in frequency of bleeding (p = .12). Approximately one-half of women who undergo radiofrequency endometrial ablation to treat heavy menstrual bleeding who also have preoperative dysmenorrhea exhibit documented pain resolution after the procedure. Resolution of dysmenorrhea is more likely if menstrual flow volume is decreased postprocedure. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  4. Clinical and Histologic Effects of Fractional Microneedling Radiofrequency Treatment on Rosacea.

    Science.gov (United States)

    Park, Seon Yong; Kwon, Hyuck Hoon; Yoon, Ji Young; Min, Seonguk; Suh, Dae Hun

    2016-12-01

    Fractional microneedling radiofrequency (FMR) is an emerging treatment modality, but its effect on rosacea has not been studied yet. To investigate the potential impact of FMR treatment on clinical improvement and histologic changes in rosacea patients. A 12-week, prospective, randomized, split-face clinical trial was conducted. Two sessions of FMR were performed on one side of the cheeks with 4-week interval and the other side remained untreated. Erythema index from DermaSpectrometer and a* value from Spectrophotometer CM-2002 were measured at each visit for the objective measurement of erythema. Histologic analysis of skin samples was also carried out. Clinical evaluation and photometric measurement revealed the reduction of redness in the treated side compared with untreated side and baseline. Erythema index decreased 13.6% and a* value decreased 6.8% at Week 12 compared with baseline. Reduced expression of markers related to inflammation, innate immunity, and angiogenesis was observed in immunohistochemical staining of tissue obtained after FMR treatment. Fractional microneedling radiofrequency treatment showed modest clinical and histologic improvement of rosacea, and it might be used as an alternative or in combination with other treatment methods.

  5. Radiofrequency Ablation Effectively Treated Focal Recurrence of Mesothelioma.

    Science.gov (United States)

    Nakamura, Akifumi; Takuwa, Teruhisa; Hashimoto, Masaki; Kondo, Nobuyuki; Takaki, Haruyuki; Fujiwara, Masayuki; Yamakado, Koichiro; Hasegawa, Seiki

    2018-02-01

    A 55-year-old man with malignant pleural mesothelioma underwent multimodality treatment comprising induction chemotherapy followed by extrapleural pneumonectomy and radiation therapy. After 2.5 years, focal recurrence occurred, with computed tomography revealing a tumor in the left cardiophrenic angle. Surgery was considered a problem for the patient because of the previous extrapleural pneumonectomy and difficult tumor location. Radiofrequency ablation was thus performed; the course was uneventful, and there was no recurrence. Radiofrequency ablation should be considered an option to treat recurrence of malignant pleural mesothelioma. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Endoscopic ultrasound-guided radiofrequency ablation of the pancreas

    DEFF Research Database (Denmark)

    Silviu, Ungureanu Bogdan; Daniel, Pirici; Claudiu, Mărgăritescu

    2015-01-01

    ultrasound (EUS)-guided radiofrequency ablation (RFA) probe through a 19G needle in order to achieve a desirable necrosis area in the pancreas. Radiofrequency ablation of the head of the pancreas was performed on 10 Yorkshire pigs with a weight between 25 kg and 35 kg and a length of 40-70 cm. Using an EUS...... analysis revealed increased values of amylase, alkaline phosphatase, and gamma-glutamyl transpeptidase on the 3rd day but a decrease on the 5th day. After necropsy and isolation of the pancreas, the ablated area was easily found, describing a solid necrosis. The pathological examination revealed...

  7. Neuronavigator-guided percutaneous radiofrequency thermocoagulation in the treatment of trigeminal neuralgia.

    Science.gov (United States)

    Zhang, W C; Zhong, W X; Li, S T; Zheng, X S; Yang, M; Shi, J

    2012-03-01

    Although radiofrequency thermocoagulation is considered as a primary treatment for most patients with trigeminal neuralgia, neuronavigator-guided percutaneous radiofrequency thermocoagulation has been rarely reported. The object of this study was to assess the clinical value of neuronavigator-guided percutaneous radiofrequency thermocoagulation in the treatment of trigeminal neuralgia. The radiofrequency thermocoagulation was performed in 100 cases of trigeminal neuralgia. The patients were positioned supine or sitting, under Hartel's technique (reported by Sweet and Wepsic J Neurosurg 40:143-156, 1974), by anterior lateral facial approaches. The Gasserian ganglions were acupunctured, assisted by intraoperative CT scanning (3-digital reconstruction) and electrophysiology in order to accurately locate target. The needles located in oval foramen at the first puncture, the direction and position could be defined according to the electrophysiology examination. The pain alleviated immediately after operation. There occurred no serious complication and other nerve injury in all patients despite face numbness only. 3D-CT and electrophysiology Gasser's ganglion locations can raise the success rate of puncture, enhance the safety and reduce the incidence of complication, showing high academic value and its promising future.

  8. Molecular identification of Coccidioides spp. in soil samples from Brazil

    OpenAIRE

    de Macêdo, Regina CL; Rosado, Alexandre S; da Mota, Fabio F; Cavalcante, Maria AS; Eulálio, Kelsen D; Filho, Antônio D; Martins, Liline MS; Lazéra, Márcia S; Wanke, Bodo

    2011-01-01

    Abstract Background Since 1991 several outbreaks of acute coccidioidomycosis (CM) were diagnosed in the semi-arid Northeast of Brazil, mainly related to disturbance of armadillo burrows caused by hunters while digging them for the capture of these animals. This activity causes dust contaminated with arthroconidia of Coccidioides posadasii, which, once inhaled, cause the mycosis. We report on the identification of C. posadasii in soil samples related to outbreaks of CM. Results Twenty four soi...

  9. Feasibility of Noninvasive Temperature Assessment During Radiofrequency Liver Ablation on Computed Tomography

    NARCIS (Netherlands)

    Pandeya, Ganga D.; Greuter, Marcel J. W.; de Jong, Koert P.; Schmidt, Bernhard; Flohr, Thomas; Oudkerk, Matthijs

    2011-01-01

    Purpose: The purpose of this study was to assess the feasibility of noninvasive thermometry using high-resolution computer tomography (CT) for the monitoring of bovine liver during radiofrequency (RF) ablation. Methods: Radiofrequency probes were used to ablate bovine livers from 20 degrees C to 98

  10. A comparative proteomics method for multiple samples based on a 18O-reference strategy and a quantitation and identification-decoupled strategy.

    Science.gov (United States)

    Wang, Hongbin; Zhang, Yongqian; Gui, Shuqi; Zhang, Yong; Lu, Fuping; Deng, Yulin

    2017-08-15

    Comparisons across large numbers of samples are frequently necessary in quantitative proteomics. Many quantitative methods used in proteomics are based on stable isotope labeling, but most of these are only useful for comparing two samples. For up to eight samples, the iTRAQ labeling technique can be used. For greater numbers of samples, the label-free method has been used, but this method was criticized for low reproducibility and accuracy. An ingenious strategy has been introduced, comparing each sample against a 18 O-labeled reference sample that was created by pooling equal amounts of all samples. However, it is necessary to use proportion-known protein mixtures to investigate and evaluate this new strategy. Another problem for comparative proteomics of multiple samples is the poor coincidence and reproducibility in protein identification results across samples. In present study, a method combining 18 O-reference strategy and a quantitation and identification-decoupled strategy was investigated with proportion-known protein mixtures. The results obviously demonstrated that the 18 O-reference strategy had greater accuracy and reliability than other previously used comparison methods based on transferring comparison or label-free strategies. By the decoupling strategy, the quantification data acquired by LC-MS and the identification data acquired by LC-MS/MS are matched and correlated to identify differential expressed proteins, according to retention time and accurate mass. This strategy made protein identification possible for all samples using a single pooled sample, and therefore gave a good reproducibility in protein identification across multiple samples, and allowed for optimizing peptide identification separately so as to identify more proteins. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Ophthalmic branch radiofrequency thermocoagulation for atypical trigeminal neuralgia:a case report.

    Science.gov (United States)

    Du, Shibin; Ma, Xiaoliang; Li, Xiaoqin; Yuan, Hongjie

    2015-01-01

    Trigeminal neuralgia is an intense neuralgia involving facial areas supplied by trigeminal nerve. The pain is characterized by sudden onset, short persistence, sharp or lancinating. Trigeminal neuralgia commonly affects frontal areas, infraorbital or paranasal areas, mandibular areas and teeth. While Trigeminal neuralgia affecting merely the upper eyelid is rare. Here we report a case of atypical Trigeminal neuralgia confined to the upper eyelid. The patient was pain free during the follow-up period of 6 months after unusual ophthalmic branch radiofrequency thermocoagulation. A 55-year-old female patient was diagnosed as primary trigeminal neuralgia involving the right upper eyelid. As the pain could not be controlled by drug therapy, peripheral nerve branch radiofrequency thermocoagulation was recommended. A combination of infratrochlear, supratrochlear and lacrimal radiofrequency thermocoagulation was implemented in this case. The point where the bridge of the nose abuts the supraorbital ridge and the point slightly above the lateral canthus along outer border of the orbit were selected respectively as the puncture sites. After positive diagnostic test, radiofrequency thermocoagulation of the above-mentioned nerve branches was performed respectively. The patient was pain free immediately after the treatment and during the follow-up period of 6 months. Trigeminal neuralgia is a common severe and chronic facial neuralgia which requires accurate diagnosis and effective therapy. With typical clinical symptoms, normal neurological signs, normal CT and MRI findings, the patient was diagnosed as classic trigeminal neuralgia. As the patient was drug resistant, some invasive treatments were considered. Peripheral branch neurolysis was chosen for its minimal invasiveness, convenience, low risk and not affecting further invasive treatments. According to the anatomic data and the diagnostic test results, infratrochlear, supratrochlear and lacrimal nerve were responsible

  12. Sphenopalatine ganglion: block, radiofrequency ablation and neurostimulation - a systematic review.

    Science.gov (United States)

    Ho, Kwo Wei David; Przkora, Rene; Kumar, Sanjeev

    2017-12-28

    Sphenopalatine ganglion is the largest collection of neurons in the calvarium outside of the brain. Over the past century, it has been a target for interventional treatment of head and facial pain due to its ease of access. Block, radiofrequency ablation, and neurostimulation have all been applied to treat a myriad of painful syndromes. Despite the routine use of these interventions, the literature supporting their use has not been systematically summarized. This systematic review aims to collect and summarize the level of evidence supporting the use of sphenopalatine ganglion block, radiofrequency ablation and neurostimulation. Medline, Google Scholar, and the Cochrane Central Register of Controlled Trials (CENTRAL) databases were reviewed for studies on sphenopalatine ganglion block, radiofrequency ablation and neurostimulation. Studies included in this review were compiled and analyzed for their treated medical conditions, study design, outcomes and procedural details. Studies were graded using Oxford Center for Evidence-Based Medicine for level of evidence. Based on the level of evidence, grades of recommendations are provided for each intervention and its associated medical conditions. Eighty-three publications were included in this review, of which 60 were studies on sphenopalatine ganglion block, 15 were on radiofrequency ablation, and 8 were on neurostimulation. Of all the studies, 23 have evidence level above case series. Of the 23 studies, 19 were on sphenopalatine ganglion block, 1 study on radiofrequency ablation, and 3 studies on neurostimulation. The rest of the available literature was case reports and case series. The strongest evidence lies in using sphenopalatine ganglion block, radiofrequency ablation and neurostimulation for cluster headache. Sphenopalatine ganglion block also has evidence in treating trigeminal neuralgia, migraines, reducing the needs of analgesics after endoscopic sinus surgery and reducing pain associated with nasal packing

  13. Cooled radiofrequency denervation for treatment of sacroiliac joint pain: two-year results from 20 cases

    Science.gov (United States)

    Ho, Kok-Yuen; Hadi, Mohamed Abdul; Pasutharnchat, Koravee; Tan, Kian-Hian

    2013-01-01

    Background Sacroiliac joint pain is a common cause of chronic low back pain. Different techniques for radiofrequency denervation of the sacroiliac joint have been used to treat this condition. However, results have been inconsistent because the variable sensory supply to the sacroiliac joint is difficult to disrupt completely using conventional radiofrequency. Cooled radiofrequency is a novel technique that uses internally cooled radiofrequency probes to enlarge lesion size, thereby increasing the chance of completely denervating the sacroiliac joint. The objective of this study was to evaluate the efficacy of cooled radiofrequency denervation using the SInergy™ cooled radiofrequency system for sacroiliac joint pain. Methods The charts of 20 patients with chronic sacroiliac joint pain who had undergone denervation using the SInergy™ cooled radiofrequency system were reviewed at two years following the procedure. Outcome measures included the Numeric Rating Scale for pain intensity, Patient Global Impression of Change, and Global Perceived Effect for patient satisfaction. Results Fifteen of 20 patients showed a significant reduction in pain (a decrease of at least three points on the Numeric Rating Scale). Mean Numeric Rating Scale for pain decreased from 7.4 ± 1.4 to 3.1 ± 2.5, mean Patient Global Impression of Change was “improved” (1.4 ± 1.5), and Global Perceived Effect was reported to be positive in 16 patients at two years following the procedure. Conclusion Cooled radiofrequency denervation showed long-term efficacy for up to two years in the treatment of sacroiliac joint pain. PMID:23869175

  14. Combination acetabular radiofrequency ablation and cementoplasty using a navigational radiofrequency ablation device and ultrahigh viscosity cement: technical note.

    Science.gov (United States)

    Wallace, Adam N; Huang, Ambrose J; Vaswani, Devin; Chang, Randy O; Jennings, Jack W

    2016-03-01

    Percutaneous radiofrequency ablation and cementoplasty is an alternative palliative therapy for painful metastases involving axial load-bearing bones. This technical report describes the use of a navigational radiofrequency probe to ablate acetabular metastases from an anterior approach followed by instillation of ultrahigh viscosity cement under CT-fluoroscopic guidance. The tumor ablation databases of two institutions were retrospectively reviewed to identify patients who underwent combination acetabular radiofrequency ablation and cementoplasty using the STAR Tumor Ablation and StabiliT Vertebral Augmentation Systems (DFINE; San Jose, CA). Pre-procedure acetabular tumor volume was measured on cross-sectional imaging. Pre- and post-procedure pain scores were measured using the Numeric Rating Scale (10-point scale) and compared. Partial pain improvement was categorically defined as ≥ 2-point pain score reduction. Patients were evaluated for evidence of immediate complications. Electronic medical records were reviewed for evidence of delayed complications. During the study period, 12 patients with acetabular metastases were treated. The median tumor volume was 54.3 mL (range, 28.3-109.8 mL). Pre- and post-procedure pain scores were obtained from 92% (11/12) of the cohort. The median pre-procedure pain score was 8 (range, 3-10). Post-procedure pain scores were obtained 7 days (82%; 9/11), 11 days (9.1%; 1/11) or 21 days (9.1%; 1/11) after treatment. The median post-treatment pain score was 3 (range, 1-8), a statistically significant difference compared with pre-treatment (P = 0.002). Categorically, 73% (8/11) of patients reported partial pain relief after treatment. No immediate symptomatic complications occurred. Three patients (25%; 3/12) were discharged to hospice within 1 week of treatment. No delayed complications occurred in the remaining 75% (9/12) of patients during median clinical follow-up of 62 days (range, 14-178 days). Palliative percutaneous

  15. Osteoid osteoma of the spine: CT-guided monopolar radiofrequency ablation

    Energy Technology Data Exchange (ETDEWEB)

    Martel, Jose [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Alcorcon, Madrid (Spain)], E-mail: jmartel@fhalcorcon.es; Bueno, Angel [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Alcorcon, Madrid (Spain); Nieto-Morales, M Luisa [Servicio de Radiologia, Hospital Universitario de Tenerife (Spain); Ortiz, Eduardo J. [Departamento de Cirugia Ortopedica, Fundacion Hospital Alcorcon, Alcorcon, Madrid (Spain)

    2009-09-15

    CT-guided percutaneous radiofrequency ablation and laser photocoagulation have become the methods of choice for the treatment of all osteoid osteomas except those in contact with neural structures. We report 10 patients with spinal osteoid osteoma adjacent to the neural elements treated with 12 sessions of CT-guided monopolar radiofrequency ablation. The size range of the lesion was 3-14 mm (mean, 7.5 mm) and the distance between the nidus and the adjacent spinal cord or nerve root was 2-12 mm (mean, 5 mm). No intact cortex between the tumor and the spinal cord or nerve roots constituted an exclusion criterion because of a higher risk of undesirable neurotoxic effects. Patients were under general anesthesia. After location of the lesion, a 11G-bone biopsy was introduced into the nidus. The radiofrequency electrode was inserted through the biopsy needle and heated at 90 deg. C for 4 min. Primary success was obtained in eight patients. At follow-up (mean, 19.5 months; range, 6-24 months), pain persisted in two patients after 2 months. Both of them were re-treated. All patients are currently pain-free and complications were not detected. In our opinion, radiofrequency ablation can also be considered the treatment of choice for spinal osteoid osteoma.

  16. Long-wave plasma radiofrequency ablation for treatment of xanthelasma palpebrarum.

    Science.gov (United States)

    Baroni, Adone

    2018-03-01

    Xanthelasma palpebrarum is the most common type of xanthoma affecting the eyelids. It is characterized by asymptomatic soft yellowish macules, papules, or plaques over the upper and lower eyelids. Many treatments are available for management of xanthelasma palpebrarum, the most commonly used include surgical excision, ablative CO 2 or erbium lasers, nonablative Q-switched Nd:YAG laser, trichloroacetic acid peeling, and radiofrequency ablation. This study aims to evaluate the effectiveness of RF ablation in the treatment of xanthelasma palpebrarum, with D.A.S. Medical portable device (Technolux, Italia), a radiofrequency tool working with long-wave plasma energy and without anesthesia. Twenty patients, 15 female and 5 male, affected by xanthelasma palpebrarum, were enrolled for long-wave plasma radiofrequency ablation treatment. The treatment consisted of 3/4 sessions that were carried out at intervals of 30 days. Treatments were well tolerated by all patients with no adverse effects and optimal aesthetic results. The procedure is very fast and can be performed without anesthesia because of the low and tolerable pain stimulation. Long-wave plasma radiofrequency ablation is an effective option for treatment of xanthelasma palpebrarum and adds an additional tool to the increasing list of medical devices for aesthetic treatments. © 2018 Wiley Periodicals, Inc.

  17. Osteoid osteoma of the spine: CT-guided monopolar radiofrequency ablation

    International Nuclear Information System (INIS)

    Martel, Jose; Bueno, Angel; Nieto-Morales, M Luisa; Ortiz, Eduardo J.

    2009-01-01

    CT-guided percutaneous radiofrequency ablation and laser photocoagulation have become the methods of choice for the treatment of all osteoid osteomas except those in contact with neural structures. We report 10 patients with spinal osteoid osteoma adjacent to the neural elements treated with 12 sessions of CT-guided monopolar radiofrequency ablation. The size range of the lesion was 3-14 mm (mean, 7.5 mm) and the distance between the nidus and the adjacent spinal cord or nerve root was 2-12 mm (mean, 5 mm). No intact cortex between the tumor and the spinal cord or nerve roots constituted an exclusion criterion because of a higher risk of undesirable neurotoxic effects. Patients were under general anesthesia. After location of the lesion, a 11G-bone biopsy was introduced into the nidus. The radiofrequency electrode was inserted through the biopsy needle and heated at 90 deg. C for 4 min. Primary success was obtained in eight patients. At follow-up (mean, 19.5 months; range, 6-24 months), pain persisted in two patients after 2 months. Both of them were re-treated. All patients are currently pain-free and complications were not detected. In our opinion, radiofrequency ablation can also be considered the treatment of choice for spinal osteoid osteoma.

  18. Radiofrequency energy in the arthroscopic treatment of knee chondral lesions: a systematic review.

    Science.gov (United States)

    Rocco, Papalia; Lorenzo, Diaz Balzani; Guglielmo, Torre; Michele, Paciotti; Nicola, Maffulli; Vincenzo, Denaro

    2016-03-01

    Cartilage debridement is one of the recommended procedures for the management of chondral defects. Radiofrequency probes allow to debride the cartilage, but may induce subchondral bone necrosis. Medline, Cochrane and Google Scholar were searched to identify studies on arthroscopic debridement of the articular cartilage of the knee using radiofrequency chondroplasty. The methodological quality of the studies was assessed using the Coleman methodology score (CMS). Monopolar and bipolar radiofrequency devices provide significantly better clinical outcomes, especially for patients with high-grade chondral lesions, compared with mechanical shaver only. Despite the original concerns regarding subchondral bone necrosis, low complication rates are reported. Heterogeneity in terms of type of device does not allow sound comparison of the published results. There is lack of evidence on the long-term effects of radiofrequency chondroplasty. Study methodology should be improved: the average Coleman methodology score was 56.2 out of 100. More comparative, well-designed and larger cohort trials are needed to ascertain whether radiofrequency chondroplasty offers long-term benefits over other simpler and more economical alternatives. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Evaluation of radiofrequency dielectric heaters workers exposure

    International Nuclear Information System (INIS)

    Benes, M.; Del Frate, S.; Villalta, R.

    2008-01-01

    Radiofrequency dielectric heaters (RFDH) are widely used in the woodworking industry for gluing laminates by applying pressure and RF heating. The workers operating such equipment remain in the vicinity of the machinery all day and can therefore be exposed to considerable levels of electric and magnetic field at RFs. This work describes the method used to measure the strength of fields generated by this particular machinery. This procedure is based on current methods cited in the literature and introduces the necessary modifications to meet this specific case. In particular, as there is often a scarcity of technical data available relating to such heaters, it is suggested that a spectrum analyser be used for measurements in the frequencies domain. On the basis of the data obtained the norms of reference are established, the instrumentation to be used in successive stages determined as well as the identification of possible sources of interference from spurious signals. Furthermore, a mapping of the field strengths is presented and the means of determining the decay curve as a function of distance. This last type of measurement is done to estimate the effectiveness of grounding the machinery. The report ends with an estimate of the exposure of workers to electromagnetic fields and also some recommendations for reducing risk. (authors)

  20. Stepwise radiofrequency ablation of Barrett's esophagus preserves esophageal inner diameter, compliance, and motility

    NARCIS (Netherlands)

    Beaumont, H.; Gondrie, J. J.; McMahon, B. P.; Pouw, R. E.; Gregersen, H.; Bergman, J. J.; Boeckxstaens, G. E.

    2009-01-01

    Background and aim: Stepwise endoscopic circumferential and focal radiofrequency ablation is safe and effective for the eradication of Barrett's esophagus. In contrast to other techniques, radiofrequency ablation appears to avoid significant esophageal scarring or stenosis. Our aim was to evaluate

  1. Value of serum GP73, AFP, and AFP-L3 in diagnosis of liver cancer and recurrence monitoring after radiofrequency ablation

    Directory of Open Access Journals (Sweden)

    ZHANG Qin

    2015-02-01

    Full Text Available ObjectiveTo explore the clinical value of three serum tumor markers, Golgi protein 73 (GP73, alpha-fetoprotein (AFP, and AFP-L3, in the diagnosis of liver cancer and recurrence monitoring after radio frequency ablation. MethodsA total of 174 patients who visited our hospital from July 2012 to October 2013 were included in the study, consisting of 86 patients with newly diagnosed liver cancer, 39 with liver cirrhosis, 29 with hepatitis, and 20 healthy controls. Among the patients with newly diagnosed liver cancer, 37 were followed up for three months after the radiofrequency ablation. Serum levels of GP73, AFP, and AFP-L3 were measured by ELISA, electrochemiluminescence, and affinity adsorption chromatography, respectively. Nonparametric tests were performed on the results of serum samples from the four groups which showed skewed distribution and were represented by median (quartile interval [M(P25-P75]. Overall comparison was made by Kruskal-Wallis H test, and comparison between groups was made by Mann-Whitney U test. Pair-matching rank-sum test was performed using Wilcoxon Signed Ranks, and categorical data were analyzed by χ2 test. ResultsThe levels of GP73, AFP, and AFP-L3 in the liver cancer group were significantly higher than those in other groups (all P<0.05. The positive rates of GP73 and AFP-L3 in the liver cancer group were significantly higher than those in other groups (all P<0.05, and the positive rates of the two markers were significantly higher than that of AFP among patients with liver cancer (P<0.05. Thirty-seven patients with newly diagnosed liver cancer were reexamined three months after radiofrequency ablation, and the preoperational AFP-L3 level in the patients who had recurrence was significantly higher than that in the patients without recurrence (P<0.05. ConclusionSerum GP73, AFP, and AFP-L3 show great values in the diagnosis of liver cancer. AFP-L3 can be used as an indicator for the identification of

  2. Superconducting Radio-Frequency Cavities

    Science.gov (United States)

    Padamsee, Hasan S.

    2014-10-01

    Superconducting cavities have been operating routinely in a variety of accelerators with a range of demanding applications. With the success of completed projects, niobium cavities have become an enabling technology, offering upgrade paths for existing facilities and pushing frontier accelerators for nuclear physics, high-energy physics, materials science, and the life sciences. With continued progress in basic understanding of radio-frequency superconductivity, the performance of cavities has steadily improved to approach theoretical capabilities.

  3. Mechanical and microstructural characteristics of meat doughs, either heated by a continuous process in a radio-frequency field or conventionally in a waterbath.

    Science.gov (United States)

    van Roon, P S; Houben, J H; Koolmees, P A; van Vliet, T; Krol, B

    1994-01-01

    Meat doughs, all having the same chemical composition, were pasteurised to a comparable heat intensity (calculated as Cook values: target level of 5 min at 100°C): (i) while flowing through a glass tube (inner diameter 50 mm) mounted in a special radio-frequency (27 MHz) heating section; (ii) after flowing unheated through the glass tube at the same rate and heated in a waterbath; and (iii) after sampling immediately after the pump and heated in a waterbath. The cooked products were sampled in the core and at the rim of the product for rheological (oscillation and uniaxial compression tests at small strain), fracture measurements (uniaxial compression tests at high strain) and microstructural evaluation (light microscopy and video image analysis). Additional core samples were used for a sensory evaluation (triangle tests) of the texture of the differently processed doughs. The fast heating rate (25-30 K/min) at a mass flow of the dough of 100 kg/h (mean velocity 0.014 m/s) during dielectrical pasteurisation affected the mechanical character, the microstructure and the triangle test results of core samples from the sausages, compared to heating in a waterbath. Flow of the unheated dough through the tube of the continuous processing equipment, followed by heating in a waterbath, had little effect on the results of the mechanical tests, the microscopical evaluation and the triangle tests. The radio-frequency heated products had both higher storage and loss moduli (were more firm), fractured at higher stress values and were considered more firm in the sensory evaluation. The microstructure of dielectrically heated versus other samples displayed a more open structure of the protein matrix with larger irregularly shaped fat particles that were surrounded by relatively thin and compact protein bridges. The effects of flow and heating method on the behaviour of rim samples were very similar to their effects on the core of the products. A comparison of the mechanical

  4. Influence of radiofrequency surgery on architecture of the palatine tonsils.

    Science.gov (United States)

    Plzak, Jan; Macokova, Pavla; Zabrodsky, Michal; Kastner, Jan; Lastuvka, Petr; Astl, Jaromir

    2014-01-01

    Radiofrequency surgery is a widely used modern technique for submucosal volume reduction of the tonsils. So far there is very limited information on morphologic changes in the human tonsils after radiofrequency surgery. We performed histopathological study of tonsillectomy specimens after previous bipolar radiofrequency induced thermotherapy (RFITT). A total of 83 patients underwent bipolar RFITT for hypertrophy of palatine tonsils. Tonsil volume reduction was measured by 3D ultrasonography. Five patients subsequently underwent tonsillectomy. Profound histopathological examination was performed to determine the effect of RFITT on tonsillar architecture. All tonsillectomy specimens showed the intact epithelium, intact germinal centers, normal vascularization, and no evidence of increased fibrosis. No microscopic morphological changes in tonsillectomy specimens after bipolar RFITT were observed. RFITT is an effective submucosal volume reduction procedure for treatment of hypertrophic palatine tonsils with no destructive effect on microscopic tonsillar architecture and hence most probably no functional adverse effect.

  5. Percutaneous Biopsy and Radiofrequency Ablation of Osteoid Osteoma with Excess Reactive New Bone Formation and Cortical Thickening Using a Battery-Powered Drill for Access: A Technical Note

    Energy Technology Data Exchange (ETDEWEB)

    Filippiadis, D., E-mail: dfilippiadis@yahoo.gr; Gkizas, C., E-mail: chgkizas@gmail.com; Kostantos, C., E-mail: drkarpen@yahoo.gr; Mazioti, A., E-mail: argyromazioti@yahoo.gr; Reppas, L., E-mail: l.reppas@yahoo.com; Brountzos, E., E-mail: ebrountz@med.uoa.gr; Kelekis, N., E-mail: kelnik@med.uoa.gr; Kelekis, A., E-mail: akelekis@med.uoa.gr [University General Hospital “ATTIKON”, 2nd Radiology Department (Greece)

    2016-10-15

    PurposeTo report our experience with the use of a battery-powered drill in biopsy and radiofrequency ablation of osteoid osteoma with excess reactive new bone formation. The battery-powered drill enables obtaining the sample while drilling.Materials and MethodsDuring the last 18 months, 14 patients suffering from painful osteoid osteoma with excess reactive new bone formation underwent CT-guided biopsy and radiofrequency ablation. In order to assess and sample the nidus of the osteoid osteoma, a battery-powered drill was used. Biopsy was performed in all cases. Then, coaxially, a radiofrequency electrode was inserted and ablation was performed with osteoid osteoma protocol. Procedure time (i.e., drilling including local anesthesia), amount of scans, technical and clinical success, and the results of biopsy are reported.ResultsAccess to the nidus through the excess reactive new bone formation was feasible in all cases. Median procedure time was 50.5 min. Histologic verification of osteoid osteoma was performed in all cases. Radiofrequency electrode was coaxially inserted within the nidus and ablation was successfully performed in all lesions. Median amount CT scans, performed to control correct positioning of the drill and precise electrode placement within the nidus was 11. There were no complications or material failure reported in our study.ConclusionsThe use of battery-powered drill facilitates access to the osteoid osteoma nidus in cases where excess reactive new bone formation is present. Biopsy needle can be used for channel creation during the access offering at the same time the possibility to extract bone samples.

  6. Increased Microleakage of Amalgam Restorations after Exposure to 2.4 Ghz Radiofrequency Electromagnetic Fields from Common Wi-Fi Routers

    Directory of Open Access Journals (Sweden)

    Mortazavi SMJ

    2017-09-01

    Full Text Available Statement of Problem: Previous studies have shown that exposure of dental amalgam fillings to MRI and mobile phones can increase microleakage of amalgam restorations. Objectives: The aim of this study was to evaluate the effects of exposure to radiofrequency radiation emitted from indoor Wi-Fi access devices on microleakage of amalgam restorations. Materials and Methods: Standard class V cavities were prepared on the buccal surfaces of 69 extracted human premolar teeth. The samples were divided into two exposure groups and one non-exposed control group of 23 teeth each. The specimens in the experimental groups were exposed to a radiofrequency (RF radiation emitted from a commercial 2.4 GHz Wi Fi router. The distance between the Wi-Fi router and samples was 30 cm and the router was exchanging data with a laptop computer that was placed 20 m away from the router. Teeth samples in the first exposure group (group A were exposed to RF for 3 days while the second exposure group (group B was exposed for 6 days. Then the teeth were sectioned and scored for microleakage under a stereomicroscope. Results: The score of microleakage was significantly higher in the exposure group A compared to that of the control group. However, the score of microleakage was not significantly different between the exposure group B and control group. Furthermore, the scores of microleakage was signifi-cantly higher in the exposure group A than that of the exposure group B. Conclusions: Exposure of patients with amalgam restorations to radiofre-quency waves emitted from commercial Wi-Fi routers can lead to in-creased microleakage of amalgam restorations.

  7. Sampling effects on the identification of roadkill hotspots: Implications for survey design.

    Science.gov (United States)

    Santos, Sara M; Marques, J Tiago; Lourenço, André; Medinas, Denis; Barbosa, A Márcia; Beja, Pedro; Mira, António

    2015-10-01

    Although locating wildlife roadkill hotspots is essential to mitigate road impacts, the influence of study design on hotspot identification remains uncertain. We evaluated how sampling frequency affects the accuracy of hotspot identification, using a dataset of vertebrate roadkills (n = 4427) recorded over a year of daily surveys along 37 km of roads. "True" hotspots were identified using this baseline dataset, as the 500-m segments where the number of road-killed vertebrates exceeded the upper 95% confidence limit of the mean, assuming a Poisson distribution of road-kills per segment. "Estimated" hotspots were identified likewise, using datasets representing progressively lower sampling frequencies, which were produced by extracting data from the baseline dataset at appropriate time intervals (1-30 days). Overall, 24.3% of segments were "true" hotspots, concentrating 40.4% of roadkills. For different groups, "true" hotspots accounted from 6.8% (bats) to 29.7% (small birds) of road segments, concentrating from 60% (lizards, lagomorphs, carnivores) of roadkills. Spatial congruence between "true" and "estimated" hotspots declined rapidly with increasing time interval between surveys, due primarily to increasing false negatives (i.e., missing "true" hotspots). There were also false positives (i.e., wrong "estimated" hotspots), particularly at low sampling frequencies. Spatial accuracy decay with increasing time interval between surveys was higher for smaller-bodied (amphibians, reptiles, small birds, small mammals) than for larger-bodied species (birds of prey, hedgehogs, lagomorphs, carnivores). Results suggest that widely used surveys at weekly or longer intervals may produce poor estimates of roadkill hotspots, particularly for small-bodied species. Surveying daily or at two-day intervals may be required to achieve high accuracy in hotspot identification for multiple species. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Radio Frequency Identification (RFID) in healthcare: a literature review.

    Science.gov (United States)

    Kolokathi, Aikaterini; Rallis, Panagiotis

    2013-01-01

    Creating and maintaining a safe and high-quality health care environment is of great importance for global community. New technologies and their applications can help us achieve this goal. Radio-Frequency Identification (RIFD) technology is considered one of those technologies and even today there are some interesting deployments in the health industry. As a result, this work aims to present the basic idea behind RFID solutions, problems that can be addressed with the adoption of RFID and the benefits of relative applications.

  9. Efficacy and safety of catheter-based radiofrequency renal denervation in stented renal arteries.

    Science.gov (United States)

    Mahfoud, Felix; Tunev, Stefan; Ruwart, Jennifer; Schulz-Jander, Daniel; Cremers, Bodo; Linz, Dominik; Zeller, Thomas; Bhatt, Deepak L; Rocha-Singh, Krishna; Böhm, Michael; Melder, Robert J

    2014-12-01

    In selected patients with hypertension, renal artery (RA) stenting is used to treat significant atherosclerotic stenoses. However, blood pressure often remains uncontrolled after the procedure. Although catheter-based renal denervation (RDN) can reduce blood pressure in certain patients with resistant hypertension, there are no data on the feasibility and safety of RDN in stented RA. We report marked blood pressure reduction after RDN in a patient with resistant hypertension who underwent previous stenting. Subsequently, radiofrequency ablation was investigated within the stented segment of porcine RA, distal to the stented segment, and in nonstented RA and compared with stent only and untreated controls. There were neither observations of thrombus nor gross or histological changes in the kidneys. After radiofrequency ablation of the nonstented RA, sympathetic nerves innervating the kidney were significantly reduced, as indicated by significant decreases in sympathetic terminal axons and reduction of norepinephrine in renal tissue. Similar denervation efficacy was found when RDN was performed distal to a renal stent. In contrast, when radiofrequency ablation was performed within the stented segment of the RA, significant sympathetic nerve ablation was not seen. Histological observation showed favorable healing in all arteries. Radiofrequency ablation of previously stented RA demonstrated that RDN provides equally safe experimental procedural outcomes in a porcine model whether the radiofrequency treatment is delivered within, adjacent, or without the stent struts being present in the RA. However, efficacious RDN is only achieved when radiofrequency ablation is delivered to the nonstented RA segment distal to the stent. © 2014 American Heart Association, Inc.

  10. Pulse-Dose Radiofrequency in Athletic Pubalgia: Preliminary Results.

    Science.gov (United States)

    Masala, Salvatore; Fiori, Roberto; Raguso, Mario; Ojango, Christine; Morini, Marco; Cuzzolino, Alessandro; Calabria, Eros; Simonetti, Giovanni

    2017-05-01

    Chronic pubalgia affects around 10% of athletes. To determine the role of pulse-dose radiofrequency (PDRF) in athletes with chronic pubalgia and investigate the causes with imaging. Prospective nonrandomized single-group study. PDRF was performed on 32 patients with a chronic pain that had been refractory to conservative therapies during the last 3 mo. The genital branches of the genitofemoral, ilioinguinal, and iliohypogastric nerves and the obturator nerve were the goals of treatment. A 10-cm, 20-gauge cannula was inserted with a percutaneous access on the upper and lower edges of the iliopubic branch. After the spindle was removed, a radiofrequency needle with a 10-mm "active tip" was inserted. The radiofrequency technique was performed with 1200 pulses at 45 V and 20-ms duration, followed by a 480-ms silent phase. The follow-up with a clinical examination was performed at 1, 3, 6, and 9 mo after the procedure. During the follow-up visits, the patients were asked to rate their pain on a 0-10 VAS scale. All of the enrolled patients completed the study. Mean VAS score before the treatment was 8.4 ± 0.6. Twenty-four patients had a reduction of pain VAS scores more than 50% during all follow-up visits and started training and physiotherapy in the days after the radiofrequency procedure. Six patients, each treated 2 times, had a reduction more than 50% of VAS scores and could start training and physiotherapy only after the 2nd procedure. One patient had no pain relief with 2 treatments. Pain intensity decreased up to 9 mo in 31 patients (mean VAS scores 3.4 ± 0.5 at 6 mo and 3.8 ± 0.9 at 9 mo). No complications were observed. PDRF is an effective and safe technique in management of chronic pubalgia in athletes.

  11. Perivascular radiofrequency renal denervation lowers blood pressure and ameliorates cardiorenal fibrosis in spontaneously hypertensive rats

    Science.gov (United States)

    Zhang, Yan; Su, Linan; Zhang, Yunrong; Wang, Qiang; Yang, Dachun; Li, De; Yang, Yongjian; Ma, Shuangtao

    2017-01-01

    Background Catheter-based renal denervation (RDN) is a promising approach to treat hypertension, but innervation patterns limit the response to endovascular RDN and the post-procedural renal artery narrowing or stenosis questions the endovascular ablation strategy. This study was performed to investigate the anti-hypertensive and target organ protective effects of perivascular RDN in spontaneously hypertensive rats (SHR). Methods SHR and normotensive Wistar-Kyoto (WKY) rats were divided into sham group (n = 10), radiofrequency ablation group (n = 20) in which rats received bilateral perivascular ablation with radiofrequency energy (2 watts), and chemical (10% phenol in 95% ethanol) ablation group (n = 12). The tail-cuff blood pressure was measured before the ablation and on day 14 and day 28 after the procedure. The plasma levels of creatinine, urea nitrogen, and catecholamines, urinary excretion of electrolytes and protein, and myocardial and glomerular fibrosis were analyzed and compared among the groups on day 28 after the procedure. Results We identified that 2-watt is the optimal radiofrequency power for perivascular RDN in rats. Perivascular radiofrequency and chemical ablation achieved roughly comparable blood pressure reduction in SHR but not in WKY on day 14 and day 28 following the procedure. Radiofrequency-mediated ablation substantially destroyed the renal nerves surrounding the renal arteries of both SHR and WKY without damaging the renal arteries and diminished the expression of tyrosine hydroxylase, the enzyme marker for postganglionic sympathetic nerves. Additionally, perivascular radiofrequency ablation also decreased the plasma catecholamines of SHR. Interestingly, both radiofrequency and chemical ablation decreased the myocardial and glomerular fibrosis of SHR, while neither increased the plasma creatinine and blood urea nitrogen nor affected the urinary excretion of electrolytes and protein when compared to sham group. Conclusions Radiofrequency

  12. Radiofrequency fields in our surroundings

    International Nuclear Information System (INIS)

    2011-01-01

    In 2010, the National Radiation Protection Authority (NRPA) with the Post and Telecommunications Authority carried out a project where it is measured radiofrequency fields from various telecom systems in homes, kindergartens, schools, offices, and urban environments. Close to 99 percent of the measurement points were found values of less than one thousandth of the maximum. No values were near the limits. (AG)

  13. Atorvastatin can ameliorate left atrial stunning induced by radiofrequency ablation for atrial fibrillation.

    Science.gov (United States)

    Xie, Ruiqin; Yang, Yingtao; Cui, Wei; Yin, Hongning; Zheng, Hongmei; Zhang, Jidong; You, Ling

    2017-09-01

    The objective of this study was to study the functional changes of the left atrium after radiofrequency ablation treatment for atrial fibrillation and the therapeutic effect of atorvastatin. Fifty-eight patients undergoing radiofrequency ablation for atrial fibrillation were randomly divided into non-atorvastatin group and atorvastatin group. Patients in the atorvastatin group were treated with atorvastatin 20 mg p.o. per night in addition to the conventional treatment of atrial fibrillation; patients in the non-atorvastatin group received conventional treatment of atrial fibrillation only. Echocardiography was performed before radiofrequency ablation operation and 1 week, 2 weeks, 3 weeks, and 4 weeks after operation. Two-dimensional ultrasound speckle tracking imaging system was used to measure the structural indexes of the left atrium. Results indicated that there was no significant change for indexes representing the structural status of the left atrium within a month after radiofrequency ablation (P > 0.05); however, there were significant changes for indexes representing the functional status of the left atrium. There were also significant changes in indexes reflecting left atrial strain status: the S and SRs of atorvastatin group were higher than those of non-atorvastatin group (P atorvastatin could improve left atrial function and shorten the duration of atrial stunning after radiofrequency ablation of atrial fibrillation.

  14. Radio-frequency wave enhanced runaway production rate

    International Nuclear Information System (INIS)

    Chan, V.S.; McClain, F.W.

    1983-01-01

    Enhancement of runaway electron production (over that of an Ohmic discharge) can be achieved by the addition of radio-frequency waves. This effect is studied analytically and numerically using a two-dimensional Fokker--Planck quasilinear equation

  15. First muon acceleration using a radio-frequency accelerator

    Directory of Open Access Journals (Sweden)

    S. Bae

    2018-05-01

    Full Text Available Muons have been accelerated by using a radio-frequency accelerator for the first time. Negative muonium atoms (Mu^{-}, which are bound states of positive muons (μ^{+} and two electrons, are generated from μ^{+}’s through the electron capture process in an aluminum degrader. The generated Mu^{-}’s are initially electrostatically accelerated and injected into a radio-frequency quadrupole linac (RFQ. In the RFQ, the Mu^{-}’s are accelerated to 89 keV. The accelerated Mu^{-}’s are identified by momentum measurement and time of flight. This compact muon linac opens the door to various muon accelerator applications including particle physics measurements and the construction of a transmission muon microscope.

  16. Molecular identification of Coccidioides spp. in soil samples from Brazil.

    Science.gov (United States)

    de Macêdo, Regina C L; Rosado, Alexandre S; da Mota, Fabio F; Cavalcante, Maria A S; Eulálio, Kelsen D; Filho, Antônio D; Martins, Liline M S; Lazéra, Márcia S; Wanke, Bodo

    2011-05-16

    Since 1991 several outbreaks of acute coccidioidomycosis (CM) were diagnosed in the semi-arid Northeast of Brazil, mainly related to disturbance of armadillo burrows caused by hunters while digging them for the capture of these animals. This activity causes dust contaminated with arthroconidia of Coccidioides posadasii, which, once inhaled, cause the mycosis. We report on the identification of C. posadasii in soil samples related to outbreaks of CM. Twenty four soil samples had their DNA extracted and subsequently submitted to a semi-nested PCR technique using specific primers. While only 6 (25%) soil samples were positive for C. posadasii by mice inoculation, all (100%) were positive by the molecular tool. This methodology represents a simple, sensitive and specific molecular technique to determine the environmental distribution of Coccidioides spp. in endemic areas, but cannot distinguish the species. Moreover, it may be useful to identify culture isolates. Key-words: 1. Coccidioidomycosis. 2. Coccidioides spp. 3. C. posadasii. 4. Semi-arid. 5. Semi-nested PCR.

  17. The efficacy of conventional radiofrequency denervation in patients with chronic low back pain originating from the facet joints: a meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Lee, Chang-Hyun; Chung, Chun Kee; Kim, Chi Heon

    2017-11-01

    Radiofrequency denervation is commonly used for the treatment of chronic facet joint pain that has been refractory to more conservative treatments, although the evidence supporting this treatment has been controversial. We aimed to elucidate the precise effects of radiofrequency denervation in patients with low back pain originating from the facet joints relative to those obtained using control treatments, with particular attention to consistency in the denervation protocol. A meta-analysis of randomized controlled trials was carried out. Adult patients undergoing radiofrequency denervation or control treatments (sham or epidural block) for facet joint disease of the lumbar spine comprised the patient sample. Visual analog scale (VAS) pain scores were measured and stratified by response of diagnostic block procedures. We searched PubMed, Embase, Web of Science, and the Cochrane Database for randomized controlled trials regarding radiofrequency denervation and control treatments for back pain. Changes in VAS pain scores of the radiofrequency group were compared with those of the control group as well as the minimal clinically important difference (MCID) for back pain VAS. Meta-regression model was developed to evaluate the effect of radiofrequency treatment according to responses of diagnostic block while controlling for other variables. We then calculated mean differences and 95% confidence intervals (CIs) using random-effects models. We included data from seven trials involving 454 patients who had undergone radiofrequency denervation (231 patients) and control treatments such as sham or epidural block procedures (223 patients). The radiofrequency group exhibited significantly greater improvements in back pain score when compared with the control group for 1-year follow-up. Although the average improvement in VAS scores exceeded the MCID, the lower limit of the 95% CI encompassed the MCID. A subgroup of patients who responded very well to diagnostic block

  18. Non-invasive ultrasound-based temperature imaging for monitoring radiofrequency heating-phantom results

    International Nuclear Information System (INIS)

    Daniels, M J; Varghese, T; Madsen, E L; Zagzebski, J A

    2007-01-01

    Minimally invasive therapies (such as radiofrequency ablation) are becoming more commonly used in the United States for the treatment of hepatocellular carcinomas and liver metastases. Unfortunately, these procedures suffer from high recurrence rates of hepatocellular carcinoma (∼34-55%) or metastases following ablation therapy. The ability to perform real-time temperature imaging while a patient is undergoing radiofrequency ablation could provide a significant reduction in these recurrence rates. In this paper, we demonstrate the feasibility of ultrasound-based temperature imaging on a tissue-mimicking phantom undergoing radiofrequency heating. Ultrasound echo signals undergo time shifts with increasing temperature, which are tracked using 2D correlation-based speckle tracking methods. Time shifts or displacements in the echo signal are accumulated, and the gradient of these time shifts are related to changes in the temperature of the tissue-mimicking phantom material using a calibration curve generated from experimental data. A tissue-mimicking phantom was developed that can undergo repeated radiofrequency heating procedures. Both sound speed and thermal expansion changes of the tissue-mimicking material were measured experimentally and utilized to generate the calibration curve relating temperature to the displacement gradient. Temperature maps were obtained, and specific regions-of-interest on the temperature maps were compared to invasive temperatures obtained using fiber-optic temperature probes at the same location. Temperature elevation during a radiofrequency ablation procedure on the phantom was successfully tracked to within ±0.5 0 C

  19. International radiofrequency standards

    International Nuclear Information System (INIS)

    Lincoln, J.

    2001-01-01

    Of the various radiofrequency standards in use around the world, many are based on or similar to the Guidelines published by ICNIRP (The International Commission on Non-ionising Radiation Protection). This organisation is a working group operating in co-operation with the Environmental Health division of the World Health Organisation (WHO). This paper presents a very brief overview of current international standards, beginning with a summary of the salient points of the ICNIRP Guidelines. It should be remembered that these are guidelines only and do not exist as a separate standard. Copyright (2001) Australasian Radiation Protection Society Inc

  20. Identification of Homophily and Preferential Recruitment in Respondent-Driven Sampling.

    Science.gov (United States)

    Crawford, Forrest W; Aronow, Peter M; Zeng, Li; Li, Jianghong

    2018-01-01

    Respondent-driven sampling (RDS) is a link-tracing procedure used in epidemiologic research on hidden or hard-to-reach populations in which subjects recruit others via their social networks. Estimates from RDS studies may have poor statistical properties due to statistical dependence in sampled subjects' traits. Two distinct mechanisms account for dependence in an RDS study: homophily, the tendency for individuals to share social ties with others exhibiting similar characteristics, and preferential recruitment, in which recruiters do not recruit uniformly at random from their network alters. The different effects of network homophily and preferential recruitment in RDS studies have been a source of confusion and controversy in methodological and empirical research in epidemiology. In this work, we gave formal definitions of homophily and preferential recruitment and showed that neither is identified in typical RDS studies. We derived nonparametric identification regions for homophily and preferential recruitment and showed that these parameters were not identified unless the network took a degenerate form. The results indicated that claims of homophily or recruitment bias measured from empirical RDS studies may not be credible. We applied our identification results to a study involving both a network census and RDS on a population of injection drug users in Hartford, Connecticut (2012-2013). © The Author(s) 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. Management of trigeminal neuralgia by radiofrequency ...

    African Journals Online (AJOL)

    The outcome depends on the type of TN with best results with classical idiopathic type. Also better results occurred with isolated V3 affection. The radiofrequency thermocoagulation of trigeminal nerve is a low risk, highly effective and minimally invasive procedure that should be started with in all cases of TN.

  2. INTRAOPERATIVE RADIOFREQUENCY AND CRYOABLATION FOR ATRIAL FIBRILLATION IN PATIENTS WITH VALVULAR HEART DISEASE

    Directory of Open Access Journals (Sweden)

    N. Maghamipour N. Safaie

    2007-05-01

    Full Text Available Patients with valvular heart disease and suffering atrial fibrillation of more than 12 months duration have a low probability of remaining in sinus rhythm after valve surgery alone. We performed intra-operative radiofrequency ablation or cryoablation as an alternative to surgical maze ІІІ procedure to create linear lesion lines for conversion of this arrhythmia to sinus rhythm. A total of 30 patients with valvular heart disease and chronic persistent atrial fibrillation underwent different combinations of valve surgery and concomitant maze procedure with radiofrequency or cryo probes. These patients aged 48.10 ± 9.84 years in radiofrequency ablation group and 51.10 ± 13.93 years in cryoablation group. Both atrial ablation with radiofrequency probes, needed 26.15 ± 3.67 min extra ischemic time and ablation by mean of cryo-probes needed an extra ischemic time of 29.62 ± 4.27 min. There was one in hospital death postoperatively because of respiratory failure but no other complication. 6 months after the operation, among 30 patients with both atrial ablations, 25 patients were in sinus rhythm, no patient had junctional rhythm and 5 patients had persistent atrial fibrillation. At 12 months follow up, freedom from atrial fibrillation was 85% in radiofrequency group and 80% in cryo group. Doppler echocardiography in these patients demonstrated atrial contractility in 70% of the patients. Intraoperative radiofrequency or cryo-ablation of both atriums are effective and less invasive alternatives for the original maze procedure to eliminate the atrial fibrillation, and can be done in patients with valvular heart disease without increasing the risk of operation.

  3. Intraarticular Pulsed Radiofrequency to Treat Refractory Lumbar Facet Joint Pain in Patients with Low Back Pain.

    Science.gov (United States)

    Chang, Min Cheol; Cho, Yun-Woo; Ahn, Da Hyun; Do, Kyung Hee

    2018-04-01

    Many treatment techniques have been used for refractory lumbar facet joint pain; however, their efficacy has been controversial. In this study, we investigated the clinical efficacy and safety of intra-articular pulsed radiofrequency for the treatment of refractory lumbar facet joint pain in patients with low back pain. Twenty patients with refractory lumbar facet joint pain were recruited, and each patient was treated via intra-articular pulsed radiofrequency. The treatment effects were measured with a numerical rating scale, and the technical accuracy of intra-articular pulsed radiofrequency treatment was evaluated independently by 2 radiologists. Any adverse events or complications also were checked. We performed intra-articular pulsed radiofrequency treatment at 48 levels of the lumbar facet joints in 20 patients (5 men and 15 women; mean age, 64.50 ± 10.65 years) with refractory lumbar facet joint pain. Pain scores were significantly reduced at 1 month, 3 months, and 6 months after treatment (P radiofrequency results in all 20 patients, without any serious adverse effects. Treatment using intra-articular pulsed radiofrequency is an alternative to other techniques in patients with refractory lumbar facet joint pain. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Ion-storage in radiofrequency electric quadrupole field

    International Nuclear Information System (INIS)

    Gheorghe, V.

    1976-01-01

    The confinement of charged particles in a quadrupole radiofrequency electric field are presented. The stability diagrams and phase space trajectories for the quadrupole mass spectrometer and for the ion trap are represented and their main characteristics are discussed. (author)

  5. Massive hematemesis after radiofrequency ablation of metastatic liver tumor with successful hemostasis achieved through transarterial embolization.

    Science.gov (United States)

    Liu, Chien-An; Chiu, Nai-Chi; Chiou, Yi-You

    2018-03-03

    Hemorrhagic complications are the most common major complications that occur after radiofrequency ablation, but hematemesis as a complication after radiofrequency ablation for hepatic tumor has not been mentioned before. A hepatogastric fistula as a delayed complication is also rare. We present the case of a 77-year-old man with severe hematemesis that occurred 2 months after radiofrequency ablation of a liver metastasis of gastric cancer. A ruptured hepatic artery pseudoaneurysm and a hepatogastric fistula were confirmed through serial imaging examinations. The current case is reported in combination with 2 rare major complications after radiofrequency ablation of a liver tumor. Copyright © 2018. Published by Elsevier Inc.

  6. Radio-frequency energy in fusion power generation

    International Nuclear Information System (INIS)

    Lawson, J.Q.; Becraft, W.R.; Hoffman, D.J.

    1983-01-01

    The history of radio-frequency (rf) energy in fusion experiments is reviewed, and the status of current efforts is described. Potential applications to tasks other than plasma heating are described, as are the research and development needs of rf energy technology

  7. Modes of oscillation in radiofrequency Paul traps

    DEFF Research Database (Denmark)

    Landa, H.; Reznik, B.; Drewsen, M.

    2012-01-01

    We examine the time-dependent dynamics of ion crystals in radiofrequency traps. The problem of stable trapping of general threedimensional crystals is considered and the validity of the pseudopotential approximation is discussed. We analytically derive the micromotion amplitude of the ions...

  8. Experiences with an identification and quantification program for inhibitor-positive milk samples.

    Science.gov (United States)

    Kress, Claudia; Seidler, Caroline; Kerp, Bianca; Schneider, Elisabeth; Usleber, Ewald

    2007-03-14

    Beta-lactam antibiotics (penicillins, cephalosporins) are still the most commonly used antibiotics for dairy cows in Germany. In routine milk testing, according to the German milk quality regulation, a positive result obtained for bulk tank milk by microbiological inhibitor tests needs no further confirmation, but results in reduced milk payment of 0.05 euros kg(-1) for one month. In some cases, however, further identification of the causative agent can be of interest, either if antimicrobial drugs have not knowingly been used recently, or if improper use of such drugs is denied. As a service for milk producers, our laboratory offers further analyses of violative milk samples, aiming at the identification and quantification of the inhibitor(s). In this program, a panel of microbiological inhibitor tests, receptor tests, and enzyme immunoassays (EIA) is used in a step-by-step analysis, which primarily focusses on beta-lactams, but also includes other compounds such as sulfonamides or tetracyclines, respectively. Here we report results for violative milk samples (n=63) analysed between 2003 and 2005. In most cases (95%), beta-lactam antibiotics could be identified, although not always at levels exceeding the respective MRL values. Penicillin G (mostly together with benzylpenicilloyl metabolites) could be identified in 74.6% of all samples. Other compounds identified were, in decreasing order, ceftiofur (11%), ampicillin/amoxicillin (6.3%), isoxazolyl penicillins (3.2%), and sulfonamides (1.6%). The results indicate that penicillin G is still the predominant antibiotic responsible for violative bulk tank milk samples as detected during regulatory control.

  9. Pulsed Dose Radiofrequency Before Ablation of Medial Branch of the Lumbar Dorsal Ramus for Zygapophyseal Joint Pain Reduces Post-procedural Pain.

    Science.gov (United States)

    Arsanious, David; Gage, Emmanuel; Koning, Jonathon; Sarhan, Mazin; Chaiban, Gassan; Almualim, Mohammed; Atallah, Joseph

    2016-01-01

    One of the potential side effects with radiofrequency ablation (RFA) includes painful cutaneous dysesthesias and increased pain due to neuritis or neurogenic inflammation. This pain may require the prescription of opioids or non-opioid analgesics to control post-procedural pain and discomfort. The goal of this study is to compare post-procedural pain scores and post-procedural oral analgesic use in patients receiving continuous thermal radiofrequency ablation versus patients receiving pulsed dose radiofrequency immediately followed by continuous thermal radiofrequency ablation for zygopophaseal joint disease. This is a prospective, double-blinded, randomized, controlled trial. Patients who met all the inclusion criteria and were not subject to any of the exclusion criteria were required to have two positive diagnostic medial branch blocks prior to undergoing randomization, intervention, and analysis. University hospital. Eligible patients were randomized in a 1:1 ratio to either receive thermal radiofrequency ablation alone (standard group) or pulsed dose radiofrequency (PDRF) immediately followed by thermal radiofrequency ablation (investigational group), all of which were performed by a single Board Certified Pain Medicine physician. Post-procedural pain levels between the two groups were assessed using the numerical pain Scale (NPS), and patients were contacted by phone on post-procedural days 1 and 2 in the morning and afternoon regarding the amount of oral analgesic medications used in the first 48 hours following the procedure. Patients who received pulsed dose radiofrequency followed by continuous radiofrequency neurotomy reported statistically significantly lower post-procedural pain scores in the first 24 hours compared to patients who received thermal radiofrequency neurotomy alone. These patients also used less oral analgesic medication in the post-procedural period. These interventions were carried out by one board accredited pain physician at one

  10. Thermal Protection with 5% Dextrose Solution Blanket During Radiofrequency Ablation

    International Nuclear Information System (INIS)

    Chen, Enn Alexandria; Neeman, Ziv; Lee, Fred T.; Kam, Anthony; Wood, Brad

    2006-01-01

    A serious complication for any thermal radiofrequency ablation is thermal injury to adjacent structures, particularly the bowel, which can result in additional major surgery or death. Several methods using air, gas, fluid, or thermometry to protect adjacent structures from thermal injury have been reported. In the cases presented in this report, 5% dextrose water (D5W) was instilled to prevent injury to the bowel and diaphragm during radiofrequency ablation. Creating an Insulating envelope or moving organs with D5W might reduce risk for complications such as bowel perforation

  11. Exposure of Ontario workers to radiofrequency fields from dielectric heaters

    International Nuclear Information System (INIS)

    Bitran, M.E.; Nishio, J.M.; Charron, D.E.

    1992-01-01

    As part of a program to assess and reduce the exposure of Ontario workers to non-ionizing radiations, stray electric and magnetic fields from 383 dielectric heaters were measured in 71 industrial establishments from 1988 to 1990. This represents a population of over 800 workers potentially exposed to radiofrequency (RE) electromagnetic fields. Electric and magnetic field strengths at the head, waist, and thigh levels of the operators, corrected by duty cycle, are presented for the different heater types surveyed. Worker exposure data and compliance with Ontario radiofrequency exposure guidelines are discussed. (author)

  12. Renal denervation for resistant hypertension using an irrigated radiofrequency balloon: 12-month results from the Renal Hypertension Ablation System (RHAS) trial.

    Science.gov (United States)

    Ormiston, John A; Watson, Timothy; van Pelt, Niels; Stewart, Ralph; Stewart, James T; White, Jonathon M; Doughty, Robert N; Stewart, Fiona; Macdonald, Rhona; Webster, Mark W I

    2013-05-20

    Renal denervation using the point-by-point application of radiofrequency energy delivered by the first-generation Symplicity system is effective in lowering office blood pressure but may be time-consuming. The OneShot Renal Denervation System with a balloon-mounted spiral electrode potentially shortens and simplifies the procedure. This study is a hypothesis-generating first-in-human study to assess feasibility, and to provide preliminary efficacy and safety data. Eligible patients had a baseline office systolic blood pressure ≥160 mmHg (or ≥150 mmHg for diabetics) and were on two or more antihypertensive medications. Nine patients were enrolled. The primary endpoint, the insertion of the OneShot balloon into each renal artery and the delivery of radiofrequency energy, was achieved in 8/9 (89%) of patients. The one failure (the first patient) was due to generator high-impedance safety shut-off threshold set too low for humans. Adverse events were minor. No patient developed renal artery stenosis. Baseline BP was 185.67 ± 18.7 mmHg and the reductions at 1, 3, 6 and 12 months were 30.1 ± 13.6 (p=0.0004), 34.2 ± 20.2 (p=0.002), 33.6 ± 32.2 (p=0.021) and 30.6 ± 22.0 (p=0.019). The OneShot renal denervation system successfully delivered radiofrequency energy to the renal arteries in a short and straightforward procedure. Australian New Zealand Clinical Trials Registry - URL: anzctr.org.au. Trial identification: ACTRN12611000987965.

  13. Radiofrequency Denervation Improves Health-Related Quality of Life in Patients with Thoracic Zygapophyseal Joint Pain.

    Science.gov (United States)

    Hambraeus, Johan; Hambraeus, Kjerstin S; Persson, Jan

    2018-05-01

    To describe a practical approach for the diagnosis and treatment of thoracic zygapophyseal joint pain and to present preliminary clinical data on the effects of this treatment approach on health-related quality of life. An observational study. Specialist outpatient pain clinic in northern Sweden. Patients with long-term thoracic pain. We describe a method of radiofrequency denervation of thoracic zygapophyseal joints. We compared health-related quality of life between patients who underwent radiofrequency denervation of thoracic zygapophyseal joints and patients who underwent radiofrequency denervation for lumbar and cervical zygapophyseal joint pain. Treatment according to the Spine Intervention Society Guidelines was performed on the lumbar region in 178 patients and in the cervical region in 55 patients. Another 82 patients were treated in the thoracic region with our proposed technique. A survival plot of improvements in health-related quality of life revealed that all three treatments were effective in 65% or more of patients. The improvement in health-related quality of life was maintained for 12 or more months after treatment in 47% to 51% of patients. Our results suggest that radiofrequency denervation of thoracic zygapophyseal joint pain is as effective as radiofrequency denervation, the standard treatment, for lumbar and cervical zygapophyseal joint pain. If these results can be confirmed by other centers, radiofrequency denervation is likely to become more widely available for the treatment of thoracic zygapophyseal joint pain.

  14. Molecular Identification of Gambierdiscus and Fukuyoa (Dinophyceae from Environmental Samples

    Directory of Open Access Journals (Sweden)

    Kirsty F. Smith

    2017-08-01

    Full Text Available Ciguatera Fish Poisoning (CFP is increasing across the Pacific and the distribution of the causative dinoflagellates appears to be expanding. Subtle differences in thecal plate morphology are used to distinguish dinoflagellate species, which are difficult to determine using light microscopy. For these reasons we sought to develop a Quantitative PCR assay that would detect all species from both Gambierdiscus and Fukuyoa genera in order to rapidly screen environmental samples for potentially toxic species. Additionally, a specific assay for F. paulensis was developed as this species is of concern in New Zealand coastal waters. Using the assays we analyzed 31 samples from three locations around New Zealand and the Kingdom of Tonga. Fourteen samples in total were positive for Gambierdiscus/Fukuyoa and two samples were also positive using the F. paulensis assay. Samples from the Kermadec Islands were further characterized using high-throughput sequencing metabarcoding. The majority of reads corresponded to Gambierdiscus species with three species identified at all sites (G. australes, G. honu and G. polynesiensis. This is the first confirmed identification of G. polynesiensis, a known ciguatoxin producer, in New Zealand waters. Other known toxin-producing genera were also detected, included Alexandrium, Amphidinium, Azadinium, Dinophysis, Ostreopsis, and Prorocentrum.

  15. Particle identification by means of fine sampling dE/dX measurements

    Energy Technology Data Exchange (ETDEWEB)

    Imanishi, A; Ishii, T; Ohshima, T; Okuno, H; Shiino, K [Tokyo Univ., Tanashi (Japan). Inst. for Nuclear Study; Naito, F [Tokyo Univ. of Agriculture and Technology, Koganei (Japan). Faculty of Technology; Matsuda, T [Osaka Univ., Toyonaka (Japan). Faculty of Engineering Science

    1983-04-01

    Identification of relativistic charged particles by means of fine sampling d E/d X measurements with a longitudinal drift chamber has been studied. Using a fast-sampling ADC (25 MHz), dE/dX was measured in a 1.4 mm gas thickness over an electron drift space of 51 mm. For the simulated 1 m long tracks of pions and electrons of 500 MeV/c, a particle separation of 10sigma - 12sigma has been obtained, where sigma is the r.m.s. resolution of the dE/dX measurement. This result with fine sampling is better by a factor of 1.7 compared to the dE/dX measurement, with 21 mm sampling thickness. Further improvement achievable by reducing the correlation between neighbouring samples and simplification of electronics by use of the delta-ray clipping method are also discussed.

  16. Radiofrequency/infrared double resonance spectroscopy of the HD+ ion

    International Nuclear Information System (INIS)

    Carrington, Alan; McNab, I.R.; Montgomerie, C.A.

    1989-01-01

    We describe a double resonance technique for obtaining radiofrequency spectra of the HD + ion in vibration-rotation levels close to the dissociation limit. Infrared transitions are driven by Doppler tuning an HD + ion beam into resonance with a carbon dioxide infrared laser, and are detected by measuring H + fragment ions produced by electric field dissociation of the upper vibration-rotation level. Radiofrequency transitions between nuclear hyperfine components of the lower vibration-rotation level are then detected through resonant increases in the H + fragment ion current. The high spectroscopic resolution obtained, and the ability to measure magnetic dipole hyperfine transitions, will enable the hyperfine constants to be determined accurately. (author)

  17. Effect of Mobile Phone Radiofrequency Electromagnetic Fields on ...

    African Journals Online (AJOL)

    olayemitoyin

    Summary: Since cell phones emit radiofrequency electromagnetic fields (EMFs), this study tested the hypothesis that cell phones placed ... mobile phones on autonomic modulation of the heart. ..... Electrocardiogram and Its Technology. J. Am.

  18. [Percutaneous radiofrequency ablation of hepatic metastases. Preliminary experience].

    Science.gov (United States)

    De Baere, T; Elias, D; Ducreux, M; Dromain, C; Kuach, V; Gamal El Din, M; Sobotka, A; Lasser, P; Roche, A

    1999-11-01

    To evaluate the efficiency of percutaneous radiofrequency ablation in the treatment of liver metastases. Eighteen patients with 31 liver metastases, mainly from colorectal cancer, 10 - 35 mm in diameter (m = 23), underwent 26 courses of percutaneous radiofrequency ablation. Fifteen patients had previously undergone hepatectomy, and 3 patients had contra-indications to surgery. Imaging guidance was ultrasound in 21 patients, CT in 4 (tumors not seen with ultrasound), and both in 1. A generator working at 450 KHz with a maximum output power of 150 W was used to treat each lesion for 18 - 20 min. Treatment was monitored with real time ultrasound. Among the 12 patients followed more than 3 months, only one of the 24 treated lesions recurred after a mean follow up of 259 ¿ 109 days. Liver disease was controlled in 8 of the 12 patients after 90 - 509 days (m = 306). Among these 8 patients, 3 were tumor free after 559, 378 and 90 days, respectively; 2 died tumor free of non-tumoral disease (pulmonary embolism, digestive bleeding); 3 developed lung metastases treated with chemotherapy (n = 2) or surgery (n = 1). Three of the 12 patients had widespread hepatic tumor occurrence, and one patient died of these metastases. Six patients experienced mild skin burns, but no major complication was observed. Radiofrequency ablation of hepatic metastases appears safe and promising in this preliminary experience. Further investigation is needed.

  19. Eight hours of nocturnal 915 MHz radiofrequency identification (RFID) exposure reduces urinary levels of melatonin and its metabolite via pineal arylalkylamine N-acetyltransferase activity in male rats.

    Science.gov (United States)

    Kim, Hye Sun; Paik, Man-Jeong; Lee, Yu Hee; Lee, Yun-Sil; Choi, Hyung Do; Pack, Jeong-Ki; Kim, Nam; Ahn, Young Hwan

    2015-01-01

    We investigated the effects of whole-body exposure to the 915 MHz radiofrequency identification (RFID) on melatonin biosynthesis and the activity of rat pineal arylalkylamine N-acetyltransferase (AANAT). Rats were exposed to RFID (whole-body specific absorption rate, 4 W/kg) for 8 h/day, 5 days/week, for weeks during the nighttime. Total volume of urine excreted during a 24-h period was collected after RFID exposure. Urinary melatonin and 6-hydroxymelatonin sulfate (6-OHMS) was measured by gas chromatography-mass spectrometry (GC-MS) and enzyme-linked immunosorbent assay (ELISA), respectively. AANAT enzyme activity was measured using liquid biphasic dif-13 fusion assay. Protein levels and mRNA expression of AANAT was 14 measured by Western blot and reverse transcription polymerase 15 chain reaction (RT-PCR) analysis, respectively. Eight hours of nocturnal RFID exposure caused a significant reduction in both urinary melatonin (p = 0. 003) and 6-OHMS (p = 0. 026). Activity, protein levels, and mRNA expression of AANAT were suppressed by exposure to RFID (p RFID exposure can cause reductions in the levels of both urinary melatonin and 6-OHMS, possibly due to decreased melatonin biosynthesis via suppression of Aanat gene transcription in the rat pineal gland.

  20. Radiofrequency Coblation Versus Intramural Bipolar Cautery for the Treatment of Inferior Turbinate Hypertrophy.

    Science.gov (United States)

    Shah, Anil N; Brewster, Douglas; Mitzen, Kelly; Mullin, David

    2015-09-01

    Compare intramural bipolar electrocautery and radiofrequency coblation in the treatment of inferior turbinate hypertrophy with regards to objective and subjective improvement in nasal obstruction, rate and type of complications, experience during the procedure, and rate of recovery. Prospective, single-blinded study. Single tertiary medical center from 2008 to 2010. Forty-one adult patients with inferior turbinate hypertrophy refractory to medical management were treated with radiofrequency coblation in one nostril and intramural bipolar cautery in the other. Subjective and objective data, including use of a Visual Analog Scale (VAS) for subjective outcomes, acoustic rhinometry, and nasal endoscopy, were then obtained from each patient comparing the 2 techniques. Radiofrequency coblation was significantly less painful than intramural bipolar cautery during the procedure (P = .03) and during the early postoperative period (P measured by acoustic rhinometry and subjective VAS outcomes. Radiofrequency coblation seems to offer an equivalent alternative to bipolar electrocautery for the treatment of inferior turbinate hypertrophy with less discomfort during the procedure and early post-operative period. © The Author(s) 2015.

  1. Single strip lesions radiofrequency denervation for treatment of sacroiliac joint pain: two years' results.

    Science.gov (United States)

    Bellini, Martina; Barbieri, Massimo

    2016-01-01

    Sacroiliac joint pain can be managed by intra-articular injections or radiofrequency of its innervation. Single strip lesions radiofrequency denervation is a new system. The objective of this study was to present one of the first utilizations of this innovative technique. 60 patients who met the diagnostic criteria for sacroiliac joint syndrome were enrolled in the study. In total, 102 single strip lesions radiofrequency denervations were performed. Pain intensity was measured with the Oswestry low back pain disability questionnaire and the Oswestry Disability Index whose scores were assessed at 1, 3, 6 and 12 months after the procedure. 91.8 % of the 102 radiofrequency treatments resulted in a reduction of more than 50% pain intensity relief at 1 month, 81.6% at 3 months and 59.16% at 6 months. In 35.7% of cases, the relief was continuative up to 1 year. No relief was observed in 12.24% of cases. The ODI scores improved significantly 1 month after the procedure, compared with the baseline scores. The ODI scores after 6 months improved very clearly compared with the baseline scores and with the 3-month scores. Single strip lesions radiofrequency denervation using the Simplicity III probe is a potential modality for intermediate term relief for patients with sacroiliac pain.

  2. [Personal identification with biometric and genetic methods].

    Science.gov (United States)

    Cabanis, Emmanuel-Alain; Le Gall, Jean-Yves; Ardaillou, Raymond

    2007-11-01

    The need for personal identification is growing in many avenues of society. To "identify" a person is to establish a link between his or her observed characteristics and those previously stored in a database. To "authenticate" is to decide whether or not someone is the person he or she claims to be. These two objectives can now be achieved by analysing biometric data and genetic prints. All biometric techniques proceed in several stages: acquisition of an image or physical parameters, encoding them with a mathematical model, comparing the results of this model with those contained in the database, and calculating the error risk. These techniques must be usable worldwide and must examine specific and permanent personal data. The most widely used are facial recognition, digital prints (flexion folds and dermatoglyphs, that offer the advantage of leaving marks), and the surface and texture of the iris. Other biometric techniques analyse behaviours such as walking, signing, typing, or speaking. Implanted radio-transmitters are another means of identification. All these systems are evaluated on the basis of the same parameters, namely the false rejection rate, the false acceptance rate, and the failure-to-enrol rate. The uses of biometrics are increasing and diversifying, and now include national and international identification systems, control of access to protected sites, criminal and victim identification, and transaction security. Genetic methods can identify individuals almost infallibly, based on short tandem repeats of 2-5 nucleotides, or microsatellites. The most recent kits analyze 11-16 independent autosomal markers. Mitochondrial DNA and Y chromosome DNA can also be analyzed. These genetic tests are currently used to identify suspected criminals or their victims from biological samples, and to establish paternity. Personal identification raises many ethical questions, however, such as when to create and how to use a database while preserving personal freedom

  3. Pulmonary venous thrombosis secondary to radiofrequency ablation of the pulmonary veins

    Directory of Open Access Journals (Sweden)

    Raquel López-Reyes

    Full Text Available Background: Pulmonary Vein Thrombosis (PVT is a rare and underdiagnosed entity produced by local mechanical nature mechanisms, vascular torsion or direct injury to the vein. PVT has been described in clinical cases or small multicenter series mainly in relation to pulmonary vein stenosis, metastatic carcinoma, fibrosing mediastinitis, as an early surgical complication of lung transplantation lobectomy and radiofrequency ablation performed in patients with atrial fibrillation, although in some cases the cause is not known. Case: We report the case of a 57 years old male with history of atrial fibrillation treated by radiofrequency ablation who was admitted in our center because of a two-week history of consistent pleuritic pain in the left hemithorax and low-grade hemoptysis and a lung consolidation treated as a pneumonia with antibiotic but not responding to medical therapy. In view of the poor evolution of the patient, computed tomography angiography was performed with findings of PVT and secondary venous infarction and anticoagulation therapy was optimized. At the end, pulmonary resection was performed due to hemorrhagic recurrence. Conclusion: PVT remains a rare complication of radiofrequency ablation and other procedures involving pulmonary veins. Clinical suspicion and early diagnosis is crucial because is a potentially life-threatening entity. Keywords: Venous thrombosis, Atrial fibrilation, Radiofrequency ablation, Hemoptysis, Lung consolidation, Lung infarction, Lung resection surgery

  4. Lesion size in relation to ablation site during radiofrequency ablation

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, A

    1998-01-01

    This study was designed to investigate the effect of the convective cooling of the tip of the ablation electrode during temperature controlled radiofrequency ablation. In vivo two different application sites in the left ventricle of anaesthetised pigs were ablated and in vitro ablation was perfor......This study was designed to investigate the effect of the convective cooling of the tip of the ablation electrode during temperature controlled radiofrequency ablation. In vivo two different application sites in the left ventricle of anaesthetised pigs were ablated and in vitro ablation...... was performed during two different flow-velocities in a tissue bath, while electrode contact pressure and position were unchanged. Target temperature was 80 degrees C. Obtained tip temperature, power consumption and lesion dimensions were measured. In vivo lesion volume, depth and width were found significantly.......61 in vitro). We conclude that during temperature controlled radiofrequency ablation lesion size differs for septal and apical left ventricular applications. Differences in convective cooling might play an important role in this respect. This is supported by our in vitro experiments, where increased...

  5. Molecular identification of Coccidioides spp. in soil samples from Brazil

    Directory of Open Access Journals (Sweden)

    Filho Antônio D

    2011-05-01

    Full Text Available Abstract Background Since 1991 several outbreaks of acute coccidioidomycosis (CM were diagnosed in the semi-arid Northeast of Brazil, mainly related to disturbance of armadillo burrows caused by hunters while digging them for the capture of these animals. This activity causes dust contaminated with arthroconidia of Coccidioides posadasii, which, once inhaled, cause the mycosis. We report on the identification of C. posadasii in soil samples related to outbreaks of CM. Results Twenty four soil samples had their DNA extracted and subsequently submitted to a semi-nested PCR technique using specific primers. While only 6 (25% soil samples were positive for C. posadasii by mice inoculation, all (100% were positive by the molecular tool. Conclusion This methodology represents a simple, sensitive and specific molecular technique to determine the environmental distribution of Coccidioides spp. in endemic areas, but cannot distinguish the species. Moreover, it may be useful to identify culture isolates. Key-words: 1. Coccidioidomycosis. 2. Coccidioides spp. 3. C. posadasii. 4. Semi-arid. 5. Semi-nested PCR

  6. Robust identification of noncoding RNA from transcriptomes requires phylogenetically-informed sampling.

    Directory of Open Access Journals (Sweden)

    Stinus Lindgreen

    2014-10-01

    Full Text Available Noncoding RNAs are integral to a wide range of biological processes, including translation, gene regulation, host-pathogen interactions and environmental sensing. While genomics is now a mature field, our capacity to identify noncoding RNA elements in bacterial and archaeal genomes is hampered by the difficulty of de novo identification. The emergence of new technologies for characterizing transcriptome outputs, notably RNA-seq, are improving noncoding RNA identification and expression quantification. However, a major challenge is to robustly distinguish functional outputs from transcriptional noise. To establish whether annotation of existing transcriptome data has effectively captured all functional outputs, we analysed over 400 publicly available RNA-seq datasets spanning 37 different Archaea and Bacteria. Using comparative tools, we identify close to a thousand highly-expressed candidate noncoding RNAs. However, our analyses reveal that capacity to identify noncoding RNA outputs is strongly dependent on phylogenetic sampling. Surprisingly, and in stark contrast to protein-coding genes, the phylogenetic window for effective use of comparative methods is perversely narrow: aggregating public datasets only produced one phylogenetic cluster where these tools could be used to robustly separate unannotated noncoding RNAs from a null hypothesis of transcriptional noise. Our results show that for the full potential of transcriptomics data to be realized, a change in experimental design is paramount: effective transcriptomics requires phylogeny-aware sampling.

  7. Radiofrequency and microwave interactions between biomolecular systems

    Czech Academy of Sciences Publication Activity Database

    Kučera, Ondřej; Cifra, Michal

    2016-01-01

    Roč. 42, č. 1 (2016), s. 1-8 ISSN 0092-0606 R&D Projects: GA ČR(CZ) GA15-17102S Institutional support: RVO:67985882 Keywords : Cell signaling * Radiofrequency * Bioelectrodynamics Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.241, year: 2016

  8. Wireless Chalcogenide Nanoionic-Based Radio-Frequency Switch

    Science.gov (United States)

    Nessel, James; Miranda, Felix

    2013-01-01

    suitable for applications such as integration into garments, RFID (radio-frequency identification) tags, and conformal structures (e.g., aircraft wings, sounding rockets contours, etc). In the case of RFID tags the innovation will provide countermeasures to attempts for identity theft and other uninvited attempts for retrieval of information. It could also be applicable to the automotive industry as well as the aerospace industry for collision avoidance and phased array radar systems, respectively

  9. Radiofrequency generation by coherently moving fluxons

    Science.gov (United States)

    Dobrovolskiy, O. V.; Sachser, R.; Huth, M.; Shklovskij, V. A.; Vovk, R. V.; Bevz, V. M.; Tsindlekht, M. I.

    2018-04-01

    A lattice of Abrikosov vortices in type II superconductors is characterized by a periodic modulation of the magnetic induction perpendicular to the applied magnetic field. For a coherent vortex motion under the action of a transport current, the magnetic induction at a given point of the sample varies in time with a washboard frequency fWB = v/d, where v is the vortex velocity and d is the distance between the vortices in the direction of motion. Here, by using a spectrum analyzer connected to a 50 nm-wide Au nanowire meander near the surface of a superconducting Nb film, we detect an ac voltage induced by coherently moving fluxons. The voltage is peaked at the washboard frequency, fWB, and its subharmonics, fTOF = fWB/5, determined by the antenna width. By sweeping the dc current value, we reveal that fWB can be tuned from 100 MHz to 1.5 GHz, thereby demonstrating that patterned normal metal/superconductor nanostructures can be used as dc-tunable generators operating in the radiofrequency range.

  10. The Biological Effects of Quadripolar Radiofrequency Sequential Application: A Human Experimental Study

    OpenAIRE

    Nicoletti, Giovanni; Cornaglia, Antonia Icaro; Faga, Angela; Scevola, Silvia

    2014-01-01

    Objective: An experimental study was conducted to assess the effectiveness and safety of an innovative quadripolar variable electrode configuration radiofrequency device with objective measurements in an ex vivo and in vivo human experimental model. Background data: Nonablative radiofrequency applications are well-established anti-ageing procedures for cosmetic skin tightening. Methods: The study was performed in two steps: ex vivo and in vivo assessments. In the ex vivo assessments the radio...

  11. The relationship between smell identification and neuropsychological domains: Results from a sample of community-dwelling adults suspected of dementia.

    Science.gov (United States)

    Goette, William F; Werry, Amy E; Schmitt, Andrew L

    2018-08-01

    This study aimed to test the theoretical relationships between smell identification and cognitive tasks based on existing neuroimaging and anatomical findings. Utilizing data collected from a memory assessment clinic, theory-derived mediation and moderation models were tested. The sample used in this study consisted of 103 (39 male, 64 female) individuals referred for memory assessments. The sample's mean education was 12.4 years (SD = 3.2), and the mean age of the sample was 77.2 years (SD = 6.3). The University of Pennsylvania Smell Identification Test (UPSIT) was a significant, partial mediator of the relationship between the Repeatable Battery for the Assessment of Neuropsychological Status (RBANS) Immediate and Delayed Memory indexes. Olfactory identification did not mediate list learning and retrieval; however, olfactory identification was a significant partial mediator of the relationship between story encoding and later memory retrieval of the story. Olfactory identification also fully mediated the relationship between a visuospatial construction task and its reconstruction from memory after a short delay. The relationship between processing speed and the olfactory identification was significantly mediated by semantic memory. Finally, the UPSIT moderated the relationship between a measure of premorbid ability, the Wechsler Test of Adult Reading, and current global cognitive functioning. Our results support theoretical relationships between olfaction and neuropsychological domains. Additionally, our results suggest that the UPSIT may serve as a proxy for cerebral integrity and is likely related to the duration of neurodegeneration.

  12. Temperature-Controlled Delivery of Radiofrequency Energy in Fecal Incontinence: A Randomized Sham-Controlled Clinical Trial.

    Science.gov (United States)

    Visscher, Arjan P; Lam, Tze J; Meurs-Szojda, Maria M; Felt-Bersma, Richelle J F

    2017-08-01

    Controlled delivery of radiofrequency energy has been suggested as treatment for fecal incontinence. The aim of this study was to determine whether the clinical response to the radiofrequency energy procedure is superior to sham in patients with fecal incontinence. This was a randomized sham-controlled clinical trial from 2008 to 2015. This study was conducted in an outpatient clinic. Forty patients with fecal incontinence in whom maximal conservative management had failed were randomly assigned to receiving either radiofrequency energy or sham procedure. Fecal incontinence was measured using the Vaizey incontinence score (range, 0-24). The impact of fecal incontinence on quality of life was measured by using the fecal incontinence quality-of-life score (range, 1-4). Measurements were performed at baseline and at 6 months. Anorectal function was evaluated using anal manometry and anorectal endosonography at baseline and at 3 months. At baseline, Vaizey incontinence score was 16.8 (SD 2.9). At t = 6 months, the radiofrequency energy group improved by 2.5 points on the Vaizey incontinence score compared with the sham group (13.2 (SD 3.1), 15.6 (SD 3.3), p = 0.02). The fecal incontinence quality-of-life score at t = 6 months was not statistically different. Anorectal function did not show any alteration. Patients with severe fecal incontinence were included in the study, thus making it difficult to generalize the results. Both radiofrequency energy and sham procedure improved the fecal incontinence score, the radiofrequency energy procedure more than sham. Although statistically significant, the clinical impact for most of the patients was negligible. Therefore, the radiofrequency energy procedure should not be recommended for patients with fecal incontinence until patient-related factors associated with treatment success are known. See Video Abstract at http://links.lww.com/DCR/A373.

  13. Longitudinal outcomes of radiofrequency ablation versus surveillance endoscopy for Barrett's esophagus with low-grade dysplasia.

    Science.gov (United States)

    Kahn, A; Al-Qaisi, M; Kommineni, V T; Callaway, J K; Boroff, E S; Burdick, G E; Lam-Himlin, D M; Temkit, M; Vela, M F; Ramirez, F C

    2018-04-01

    Radiofrequency ablation of Barrett's esophagus with low-grade dysplasia is recommended in recent American College of Gastroenterology guidelines, with endoscopic surveillance considered a reasonable alternative. Few studies have directly compared outcomes of radiofrequency ablation to surveillance and those that have are limited by short duration of follow-up. This study aims to compare the long-term effectiveness of radiofrequency ablation versus endoscopic surveillance in a large, longitudinal cohort of patients with Barrett's esophagus, and low-grade dysplasia.We conducted a retrospective analysis of patients with confirmed low-grade dysplasia at a single academic medical center from 1991 to 2014. Patients progressing to high-grade dysplasia or esophageal adenocarcinoma within one year of index LGD endoscopy were defined as missed dysplasia and excluded. Risk factors for progression were assessed via Cox proportional hazards model. Comparison of progression risk was conducted using a Kaplan-Meier analysis. Subset analyses were conducted to examine the effect of reintroducing early progressors and excluding patients diagnosed prior to the advent of ablative therapy. Of 173 total patients, 79 (45.7%) underwent radiofrequency ablation while 94 (54.3%) were untreated, with median follow up of 90 months. Seven (8.9%) patients progressed to high-grade dysplasia or adenocarcinoma despite ablation, compared with 14 (14.9%) undergoing surveillance (P = 0.44). This effect was preserved when patients diagnosed prior to the introduction of radiofrequency ablation were excluded (8.9% vs 13%, P = 0.68). Reintroduction of patients progressing within the first year of follow-up resulted in a trend toward significance for ablation versus surveillance (11.1% vs 23.8%, P = 0.053).In conclusion, progression to high-grade dysplasia or adenocarcinoma was not significantly reduced in the radiofrequency ablation cohort when compared to surveillance. Despite recent studies

  14. Large magnitude gridded ionization chamber for impurity identification in alpha emitting radioactive samples

    International Nuclear Information System (INIS)

    Santos, R.N. dos.

    1992-01-01

    This paper refers to a large magnitude gridded ionization chamber with high resolution used in the identification of α radioactive samples. The chamber and the electrode have been described in terms of their geometry and dimensions, as well as the best results listed accordingly. Several α emitting radioactive samples were used with a gas mixture of 90% Argon plus 10% Methane. We got α energy spectrum with resolution around 22,14 KeV in agreement to the best results available in the literature. The spectrum of α energy related to 92 U 233 was gotten using the ionization chamber mentioned in this work; several values were found which matched perfectly well adjustment curve of the chamber. Many other additional measures using different kinds of adjusted detectors were successfully obtained in order to confirm the results gotten in the experiments, thus leading to the identification of some elements of the 92 U 233 radioactive series. Such results show the possibility of using the chamber mentioned for measurements of α low activity contamination. (author)

  15. Phase identification of quasi-periodic flow measured by particle image velocimetry with a low sampling rate

    International Nuclear Information System (INIS)

    Pan, Chong; Wang, Hongping; Wang, Jinjun

    2013-01-01

    This work mainly deals with the proper orthogonal decomposition (POD) time coefficient method used for extracting phase information from quasi-periodic flow. The mathematical equivalence between this method and the traditional cross-correlation method is firstly proved. A two-dimensional circular cylinder wake flow measured by time-resolved particle image velocimetry within a range of Reynolds numbers is then used to evaluate the reliability of this method. The effect of both the sampling rate and Reynolds number on the identification accuracy is finally discussed. It is found that the POD time coefficient method provides a convenient alternative for phase identification, whose feasibility in low-sampling-rate measurement has additional advantages for experimentalists. (paper)

  16. Radiofrequency Ablation in Coccydynia: A Case Series and Comprehensive, Evidence-Based Review.

    Science.gov (United States)

    Chen, Yian; Huang-Lionnet, Julie H Y; Cohen, Steven P

    2017-06-01

    Coccydynia is a condition with a multitude of different causes, characterized by ill-defined management. There are multiple prospective studies, including several controlled trials, that have evaluated conservative therapies. Additionally, a plethora of observational studies have assessed coccygectomy, but few studies have reported results for nonsurgical interventional procedures. In this report, we describe the treatment results of 12 patients who received conventional or pulsed radiofrequency for coccydynia and systematically review the literature on management. We performed a retrospective data analysis evaluating patients who underwent pulsed or conventional radiofrequency treatment at Johns Hopkins Hospital and Walter Reed National Military Medical Center. A comprehensive literature review was also performed to contextualize these results. The mean age of patients treated was 50.25 years (SD = 11.20 years, range = 32-72 years), with the mean duration of symptoms being 3.6 years (SD = 3.36 years, range 1-10 years). There were 10 males and two females in this cohort. Among patients who received radiofrequency treatment, the average benefit was 55.5% pain relief (SD = 30.33%, range = 0-100%). Those who underwent conventional (vs pulsed radiofrequency) and who received prognostic blocks were more likely to experience a positive outcome. There were two cases of neuritis, which resolved spontaneously after several weeks. Radiofrequency ablation of the sacrococcygeal nerves may serve as a useful treatment option for patients with coccydynia who have failed more conservative measures. Further research into this therapeutic approach and its benefit for coccydynia should incorporate a control group for comparison. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  17. Sparse feature learning for instrument identification: Effects of sampling and pooling methods.

    Science.gov (United States)

    Han, Yoonchang; Lee, Subin; Nam, Juhan; Lee, Kyogu

    2016-05-01

    Feature learning for music applications has recently received considerable attention from many researchers. This paper reports on the sparse feature learning algorithm for musical instrument identification, and in particular, focuses on the effects of the frame sampling techniques for dictionary learning and the pooling methods for feature aggregation. To this end, two frame sampling techniques are examined that are fixed and proportional random sampling. Furthermore, the effect of using onset frame was analyzed for both of proposed sampling methods. Regarding summarization of the feature activation, a standard deviation pooling method is used and compared with the commonly used max- and average-pooling techniques. Using more than 47 000 recordings of 24 instruments from various performers, playing styles, and dynamics, a number of tuning parameters are experimented including the analysis frame size, the dictionary size, and the type of frequency scaling as well as the different sampling and pooling methods. The results show that the combination of proportional sampling and standard deviation pooling achieve the best overall performance of 95.62% while the optimal parameter set varies among the instrument classes.

  18. Pulsed radiofrequency on radial nerve under ultrasound guidance for treatment of intractable lateral epicondylitis.

    Science.gov (United States)

    Oh, Dae Seok; Kang, Tae Hyung; Kim, Hyae Jin

    2016-06-01

    Lateral epicondylitis is a painful and functionally limiting disorder. Although lateral elbow pain is generally self-limiting, in a minority of people symptoms persist for a long time. When various conservative treatments fail, surgical approach is recommended. Surgical denervation of several nerves that innervate the lateral humeral epicondyle could be considered in patients with refractory pain because it denervates the region of pain. Pulsed radiofrequency is a minimally invasive procedure that improves chronic pain when applied to various neural tissues without causing any significant destruction and painful complication. This procedure is safe, minimally invasive, and has less risk of complications relatively compared to the surgical approach. The radial nerve can be identified as a target for pulsed radiofrequency lesioning in lateral epicondylitis. This innovative method of pulsed radiofrequency applied to the radial nerve has not been reported before. We reported on two patients with intractable lateral epicondylitis suffering from elbow pain who did not respond to nonoperative treatments, but in whom the ultrasound-guided pulsed radiofrequency neuromodulation of the radial nerve induced symptom improvement. After a successful diagnostic nerve block, radiofrequency probe adjustment around the radial nerve was performed on the lateral aspect of the distal upper arm under ultrasound guidance and multiple pulsed treatments were applied. A significant reduction in pain was reported over the follow-up period of 12 weeks.

  19. Sample Identification at Scale - Implementing IGSN in a Research Agency

    Science.gov (United States)

    Klump, J. F.; Golodoniuc, P.; Wyborn, L. A.; Devaraju, A.; Fraser, R.

    2015-12-01

    Earth sciences are largely observational and rely on natural samples, types of which vary significantly between science disciplines. Sharing and referencing of samples in scientific literature and across the Web requires the use of globally unique identifiers essential for disambiguation. This practice is very common in other fields, e.g. ISBN in publishing, doi in scientific literature, etc. In Earth sciences however, this is still often done in an ad-hoc manner without the use of unique identifiers. The International Geo Sample Number (IGSN) system provides a persistent, globally unique label for identifying environmental samples. As an IGSN allocating agency, CSIRO implements the IGSN registration service at the organisational scale with contributions from multiple research groups. Capricorn Distal Footprints project is one of the first pioneers and early adopters of the technology in Australia. For this project, IGSN provides a mechanism for identification of new and legacy samples, as well as derived sub-samples. It will ensure transparency and reproducibility in various geochemical sampling campaigns that will involve a diversity of sampling methods. Hence, diverse geochemical and isotopic results can be linked back to the parent sample, particularly where multiple children of that sample have also been analysed. The IGSN integration for this project is still in early stages and requires further consultations on the governance mechanisms that we need to put in place to allow efficient collaboration within CSIRO and collaborating partners on the project including naming conventions, service interfaces, etc. In this work, we present the results of the initial implementation of IGSN in the context of the Capricorn Distal Footprints project. This study has so far demonstrated the effectiveness of the proposed approach, while maintaining the flexibility to adapt to various media types, which is critical in the context of a multi-disciplinary project.

  20. Ultrafast electron diffraction with megahertz MeV electron pulses from a superconducting radio-frequency photoinjector

    Energy Technology Data Exchange (ETDEWEB)

    Feng, L. W.; Lin, L.; Huang, S. L.; Quan, S. W.; Hao, J. K.; Zhu, F.; Wang, F.; Liu, K. X., E-mail: kxliu@pku.edu.cn [Institute of Heavy Ion Physics and State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871 (China); Jiang, T.; Zhu, P. F.; Fu, F.; Wang, R.; Zhao, L.; Xiang, D., E-mail: dxiang@sjtu.edu.cn [Key Laboratory for Laser Plasmas (Ministry of Education), Department of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai 200240 (China); IFSA Collaborative Innovation Center, Shanghai Jiao Tong University, Shanghai 200240 (China)

    2015-11-30

    We report ultrafast relativistic electron diffraction operating at the megahertz repetition rate where the electron beam is produced in a superconducting radio-frequency (rf) photoinjector. We show that the beam quality is sufficiently high to provide clear diffraction patterns from gold and aluminium samples. With the number of electrons, several orders of magnitude higher than that from a normal conducting photocathode rf gun, such high repetition rate ultrafast MeV electron diffraction may open up many new opportunities in ultrafast science.

  1. Effect of radiofrequency radiation from Wi-Fi devices on mercury release from amalgam restorations.

    Science.gov (United States)

    Paknahad, Maryam; Mortazavi, S M J; Shahidi, Shoaleh; Mortazavi, Ghazal; Haghani, Masoud

    2016-01-01

    Dental amalgam is composed of approximately 50% elemental mercury. Despite concerns over the toxicity of mercury, amalgam is still the most widely used restorative material. Wi-Fi is a rapidly using local area wireless computer networking technology. To the best of our knowledge, this is the first study that evaluates the effect of exposure to Wi-Fi signals on mercury release from amalgam restorations. Standard class V cavities were prepared on the buccal surfaces of 20 non-carious extracted human premolars. The teeth were randomly divided into 2 groups (n = 10). The control group was stored in non-environment. The specimens in the experimental groups were exposed to a radiofrequency radiation emitted from standard Wi Fi devices at 2.4 GHz for 20 min. The distance between the Wi-Fi router and samples was 30 cm and the router was exchanging data with a laptop computer that was placed 20 m away from the router. The concentration of mercury in the artificial saliva in the groups was evaluated by using a cold-vapor atomic absorption Mercury Analyzer System. The independent t test was used to evaluate any significant differences in mercury release between the two groups. The mean (±SD) concentration of mercury in the artificial saliva of the Wi-Fi exposed teeth samples was 0.056 ± .025 mg/L, while it was only 0.026 ± .008 mg/L in the non-exposed control samples. This difference was statistically significant (P =0.009). Exposure of patients with amalgam restorations to radiofrequency radiation emitted from conventional Wi-Fi devices can increase mercury release from amalgam restorations.

  2. Association between success rate and citation count of studies of radiofrequency catheter ablation for atrial fibrillation: possible evidence of citation bias.

    Science.gov (United States)

    Perino, Alexander C; Hoang, Donald D; Holmes, Tyson H; Santangeli, Pasquale; Heidenreich, Paul A; Perez, Marco V; Wang, Paul J; Turakhia, Mintu P

    2014-09-01

    The preferential citation of studies with the highest success rates could exaggerate perceived effectiveness, particularly for treatments with widely varying published success rates such as radiofrequency catheter ablation for atrial fibrillation. We systematically identified observational studies and clinical trials of radiofrequency catheter ablation of atrial fibrillation between 1990 and 2012. Generalized Poisson regression was used to estimate association between study success rate and total citation count, adjusting for sample size, journal impact factor, time since publication, study design, and whether first or last author was a consensus-defined pre-eminent expert. We identified 174 articles meeting our inclusion criteria (36 289 subjects). After adjustment only for time since publication, a 10-point increase above the mean in pooled reported success rates was associated with a 17.8% increase in citation count at 5 years postpublication (95% confidence interval, 7.1-28.4%; Pcitation count; 95% confidence interval, 7.6-29.6%; Pcitation count, which may indicate citation bias. To readers of the literature, radiofrequency catheter ablation of atrial fibrillation could be perceived to be more effective than the data supports. These findings may have implications for a wide variety of novel cardiovascular therapies. © 2014 American Heart Association, Inc.

  3. TU-H-BRA-01: The Physics of High Power Radiofrequency Isolation in a Novel Compact Linear Accelerator Based MRI Guided Radiation Therapy System

    Energy Technology Data Exchange (ETDEWEB)

    Lamb, J; Low, D [University of California, Los Angeles, Los Angeles, CA (United States); Mutic, S [Washington University School of Medicine, Saint Louis, MO (United States); Shvartsman, S; Chmielewski, T; Fought, G; Sharma, A; Dempsey, J [ViewRay, Inc., Oakwood Village, OH (United States)

    2016-06-15

    Purpose: To develop a method for isolating the radiofrequency waves emanating from linear accelerator components from the magnetic resonance imaging (MRI) system of an integrated MRI-linac. Methods: An MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. The radiofrequency waves created by the accelerating process would degrade MR image quality, so a method for containing the radiofrequency waves and isolating the MR imager from them was developed. The linear accelerator radiofrequency modulator was placed outside the room, so a filter was designed to eliminate the radiofrequency corresponding to the proton Larmour frequency of 14.7 MHz. Placing the radiofrequency emitting components in a typical Faraday cage would have reduced the radiofrequency emissions, but the design would be susceptible to small gaps in the shield due to the efficiency of the Faraday cage reflecting internal radiofrequency emissions. To reduce internal radiofrequency reflections, the Faraday cage was lined with carbon fiber sheets. Carbon fiber has the property of attenuating the radiofrequency energy so that the overall radiofrequency field inside the Faraday cage is reduced, decreasing any radiofrequency energy emitted from small gaps in the cage walls. Results: Within a 1.2 MHz band centered on the Larmor frequency, the radiofrequency (RF) leakage from the Faraday cage was measured to be −90 dB with no RF on, −40 dB with the RF on and no shield, returning to −90 dB with the RF on and shields in place. The radiofrequency filter attenuated the linear accelerator modulator emissions in the 14.7 MHz band by 70 dB. Conclusions: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of isolating the high power RF system from the MRI, has been solved. The measured radiofrequency emissions are sufficiently small to enable system integration. This research was

  4. TU-H-BRA-01: The Physics of High Power Radiofrequency Isolation in a Novel Compact Linear Accelerator Based MRI Guided Radiation Therapy System

    International Nuclear Information System (INIS)

    Lamb, J; Low, D; Mutic, S; Shvartsman, S; Chmielewski, T; Fought, G; Sharma, A; Dempsey, J

    2016-01-01

    Purpose: To develop a method for isolating the radiofrequency waves emanating from linear accelerator components from the magnetic resonance imaging (MRI) system of an integrated MRI-linac. Methods: An MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. The radiofrequency waves created by the accelerating process would degrade MR image quality, so a method for containing the radiofrequency waves and isolating the MR imager from them was developed. The linear accelerator radiofrequency modulator was placed outside the room, so a filter was designed to eliminate the radiofrequency corresponding to the proton Larmour frequency of 14.7 MHz. Placing the radiofrequency emitting components in a typical Faraday cage would have reduced the radiofrequency emissions, but the design would be susceptible to small gaps in the shield due to the efficiency of the Faraday cage reflecting internal radiofrequency emissions. To reduce internal radiofrequency reflections, the Faraday cage was lined with carbon fiber sheets. Carbon fiber has the property of attenuating the radiofrequency energy so that the overall radiofrequency field inside the Faraday cage is reduced, decreasing any radiofrequency energy emitted from small gaps in the cage walls. Results: Within a 1.2 MHz band centered on the Larmor frequency, the radiofrequency (RF) leakage from the Faraday cage was measured to be −90 dB with no RF on, −40 dB with the RF on and no shield, returning to −90 dB with the RF on and shields in place. The radiofrequency filter attenuated the linear accelerator modulator emissions in the 14.7 MHz band by 70 dB. Conclusions: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of isolating the high power RF system from the MRI, has been solved. The measured radiofrequency emissions are sufficiently small to enable system integration. This research was

  5. Evaluation of microneedling fractional radiofrequency device for treatment of acne scars

    Directory of Open Access Journals (Sweden)

    Byalekere Shivanna Chandrashekar

    2014-01-01

    Full Text Available Background: Various treatment modalities including non-invasive methods such as chemical peels, topical retinoids, microdermabrasion, minimally invasive techniques such as microneedling, fractional lasers, microneedling radiofrequency devices and invasive procedures such as acne scar surgeries and ablative lasers are used for acne scars, each with its own unique advantages and disadvantages. This study is a retrospective assessment of efficacy and safety of microneedling fractional radiofrequency in the treatment of acne scars. Methods: Thirty one patients of skin types III-V with moderate and severe facial acne scarring received four sequential fractional radiofrequency treatments over a period of 6 months with an interval of 6 weeks between each session. Goodman & Baron′s acne scar grading system was used for assessment by a side by side comparison of preoperative and post- operative photographs taken at their first visit and at the end of 3 months after the last session. Results: Estimation of improvement with Goodman and Baron′s Global Acne Scarring System showed that by qualitative assessment of 31 patients with grade 3 and grade 4 acne scars, 80.64% showed improvement by 2 grades and 19.35% showed improvement by 1 grade. Quantitative assessment showed that 58% of the patients had moderate, 29% had minimal, 9% had good and 3% showed very good improvement. Adverse effects were limited to transient pain, erythema, edema and hyperpigmentation. Conclusion: Microneedling fractional radiofrequency is efficacious for the treatment of moderate and severe acne scars.

  6. Vacuum pumping system for the JT-60 radio-frequency heating system

    International Nuclear Information System (INIS)

    Yokokura, Kenji; Ikeda, Yoshitaka; Imai, Tuyoshi; Suganuma, Kazuaki; Nagashima, Takashi

    1988-01-01

    The basic design requirements set up for the JT-60 radio-frequency heating system included: (1) rapid pumping of gas released upon application of a radio-frequency power to maintain the pressure in the launchers at 10 -2 - 10 -3 Pa or less, (2) incorporation of a gas analysis system that can operate under a strong field and high pressure (>10 -2 Pa) to permit remote controlled data collection and processing, and (3) low cost, multiple functions and high reliability. The vacuum pumping system, consisting of three units for low hybrid radio-frequency (LHRF) and one unit for ion cyclotron radio-frequency (ICRF), is connected to each launcher provided at the four ports of JT-60. The LHRF unit is composed of a main pump, an alumina joint for electrical insulation from the launcher, a metallic gate valve for isolation from the JT-60 vacuum region, and various vacuum gauges. Only a turbo-molecular pump is used for the ICRF system because a large-scale differential pumping is not required. A gas measuring system is incorporated which consists of a mass filter, personal computer, turbo-molecular pump, and variable flow valve equipped with an APG control. This system is designed to identify and make use of gas impurities released during the launcher aging process. The control system employed consists of a personal computer, interlock control board, data logger and other devices such as vacuum gages. (Nogami, K.)

  7. Aspirin in Preventing Disease Recurrence in Patients With Barrett Esophagus After Successful Elimination by Radiofrequency Ablation | Division of Cancer Prevention

    Science.gov (United States)

    This randomized phase II trial studies the safety of and how well aspirin works in preventing Barrett's esophagus from returning after it has been successfully eliminated by radiofrequency ablation. Studying samples of tissue from patients with Barrett's esophagus for the levels of a specific protein that is linked to developing Barrett's esophagus may help doctors learn

  8. Novel high-resolution temperature probe for radiofrequency dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Schuderer, Juergen [Foundation for Research on Information Technologies in Society (IT' IS), Integrated Systems Laboratory IIS, Swiss Federal Institute of Technology (ETH), CH-8092 Zurich (Switzerland); Schmid, Thomas [Schmid and Partner Engineering AG, 8004 Zurich (Switzerland); Urban, Gerald [IMTEK, Albert-Ludwigs University Freiburg, 79110 Freiburg (Germany); Samaras, Theodoros [Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Kuster, Niels [Foundation for Research on Information Technologies in Society (IT' IS), Integrated Systems Laboratory IIS, Swiss Federal Institute of Technology (ETH), CH-8092 Zurich (Switzerland)

    2004-03-21

    A novel integrated thermistor probe for temperature evaluations in radiofrequency-heated environments was realized. The probe's sensitive area is based on a highly resistive 50 {mu}m x 100 {mu}m layer of amorphous germanium processed on a glass tip. The small dimensions allow measurements with a distance as close as 150 {mu}m from solid boundaries. Due to its high temperature resolution of 4 mK and its short response time of the order of 10 ms, the sensor is very well suited for dosimetric measurements in strong absorption gradients. The influence of radiofrequency (RF) electric fields on the signal is minimized due to the high resistance of the sensor and the leads. The probe was successfully used to determine the highly nonuniform absorption distribution resulting from the RF exposure of cell cultures placed in Petri dishes. (note)

  9. Novel high-resolution temperature probe for radiofrequency dosimetry

    International Nuclear Information System (INIS)

    Schuderer, Juergen; Schmid, Thomas; Urban, Gerald; Samaras, Theodoros; Kuster, Niels

    2004-01-01

    A novel integrated thermistor probe for temperature evaluations in radiofrequency-heated environments was realized. The probe's sensitive area is based on a highly resistive 50 μm x 100 μm layer of amorphous germanium processed on a glass tip. The small dimensions allow measurements with a distance as close as 150 μm from solid boundaries. Due to its high temperature resolution of 4 mK and its short response time of the order of 10 ms, the sensor is very well suited for dosimetric measurements in strong absorption gradients. The influence of radiofrequency (RF) electric fields on the signal is minimized due to the high resistance of the sensor and the leads. The probe was successfully used to determine the highly nonuniform absorption distribution resulting from the RF exposure of cell cultures placed in Petri dishes. (note)

  10. The efficacy of intraperitoneal saline infusion for percutaneous radiofrequency ablation for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Park, Soo Young; Tak, Won Young; Jeon, Seong Woo; Cho, Chang Min; Kweon, Young Oh; Kim, Sung Kook; Choi, Yong Hwan

    2010-01-01

    Objective: To evaluated the efficacy and safety of radiofrequency ablation (RFA) with intraperitoneal saline infusion. Background: Ultrasound-guided RFA is not always feasible due to the tumor location, possible adjacent tissue damage or poor sonographic identification. Patients and methods: Ultrasound-guided RFA with intraperitoneal saline infusion was performed in 116 patients between June 2001 and March 2008. Results: The overall technical feasibility of the intraperitoneal saline infusions was 90.5% (105 patients). The purposes of the intraperitoneal saline infusion were achieved in 100 patients (86.2%) by visualizing the tumor located in hepatic dome (47 patients), prevent adjacent organ damage (42 patients) and withdrawing overlying omentum (10 patients). Complete ablation of tumor was accomplished in 102 patients (87.9%). Complications associated with the treatment occurred in seven patients (6.0%). There was no case of adverse event directly related to intraperitoneal saline infusion. Conclusions: Intraperitoneal saline infusion is an effective and safe procedure that can be used to overcome the current limitations of ultrasound-guided RFA.

  11. Potential health risks due to telecommunications radiofrequency ...

    African Journals Online (AJOL)

    Background: The global system mobile telecommunications system (GSM) which was recently introduced in Nigeria is now being used by over 40 million people in Nigeria. The use of GSM is accompanied with exposure of the users to radiofrequency radiation (RFR), which if significant, may produce health hazards. This is ...

  12. Non-exponential decoherence of radio-frequency resonance rotation of spin in storage rings

    Science.gov (United States)

    Saleev, A.; Nikolaev, N. N.; Rathmann, F.; Hinder, F.; Pretz, J.; Rosenthal, M.

    2017-08-01

    Precision experiments, such as the search for electric dipole moments of charged particles using radio-frequency spin rotators in storage rings, demand for maintaining the exact spin resonance condition for several thousand seconds. Synchrotron oscillations in the stored beam modulate the spin tune of off-central particles, moving it off the perfect resonance condition set for central particles on the reference orbit. Here, we report an analytic description of how synchrotron oscillations lead to non-exponential decoherence of the radio-frequency resonance driven up-down spin rotations. This non-exponential decoherence is shown to be accompanied by a nontrivial walk of the spin phase. We also comment on sensitivity of the decoherence rate to the harmonics of the radio-frequency spin rotator and a possibility to check predictions of decoherence-free magic energies.

  13. Molecular species identification with rich floristic sampling: DNA barcoding the pteridophyte flora of Japan.

    Directory of Open Access Journals (Sweden)

    Atsushi Ebihara

    Full Text Available BACKGROUND: DNA barcoding is expected to be an effective identification tool for organisms with heteromorphic generations such as pteridophytes, which possess a morphologically simple gametophyte generation. Although a reference data set including complete coverage of the target local flora/fauna is necessary for accurate identification, DNA barcode studies including such rich taxonomic sampling on a countrywide scale are lacking. METHODOLOGY/PRINCIPAL FINDINGS: The Japanese pteridophyte flora (733 taxa including subspecies and varieties was used to test the utility of two plastid DNA barcode regions (rbcL and trnH-psbA with the intention of developing an identification system for native gametophytes. DNA sequences were obtained from each of 689 (94.0% taxa for rbcL and 617 (84.2% taxa for trnH-psbA. Mean interspecific divergence values across all taxon pairs (K2P genetic distances did not reveal a significant difference in rate between trnH-psbA and rbcL, but mean K2P distances of each genus showed significant heterogeneity according to systematic position. The minimum fail rate of taxon discrimination in an identification test using BLAST (12.52% was obtained when rbcL and trnH-psbA were combined, and became lower in datasets excluding infraspecific taxa or apogamous taxa, or including sexual diploids only. CONCLUSIONS/SIGNIFICANCE: This study demonstrates the overall effectiveness of DNA barcodes for species identification in the Japanese pteridophyte flora. Although this flora is characterized by a high occurrence of apogamous taxa that pose a serious challenge to identification using DNA barcodes, such taxa are limited to a small number of genera, and only minimally detract from the overall success rate. In the case that a query sequence is matched to a known apogamous genus, routine species identification may not be possible. Otherwise, DNA barcoding is a practical tool for identification of most Japanese pteridophytes, and is especially

  14. Comparison of microbubble presence in the right heart during mechanochemical and radiofrequency ablation for varicose veins.

    Science.gov (United States)

    Moon, K H; Dharmarajah, B; Bootun, R; Lim, C S; Lane, Tra; Moore, H M; Sritharan, K; Davies, A H

    2017-07-01

    Objective Mechanochemical ablation is a novel technique for ablation of varicose veins utilising a rotating catheter and liquid sclerosant. Mechanochemical ablation and radiofrequency ablation have no reported neurological side-effect but the rotating mechanism of mechanochemical ablation may produce microbubbles. Air emboli have been implicated as a cause of cerebrovascular events during ultrasound-guided foam sclerotherapy and microbubbles in the heart during ultrasound-guided foam sclerotherapy have been demonstrated. This study investigated the presence of microbubbles in the right heart during varicose vein ablation by mechanochemical abaltion and radiofrequency abaltion. Methods Patients undergoing great saphenous vein ablation by mechanochemical abaltion or radiofrequency ablation were recruited. During the ablative procedure, the presence of microbubbles was assessed using transthoracic echocardiogram. Offline blinded image quantification was performed using International Consensus Criteria grading guidelines. Results From 32 recruited patients, 28 data sets were analysed. Eleven underwent mechanochemical abaltion and 17 underwent radiofrequency abaltion. There were no neurological complications. In total, 39% (11/28) of patients had grade 1 or 2 microbubbles detected. Thirty-six percent (4/11) of mechanochemical abaltion patients and 29% (5/17) of radiofrequency ablation patients had microbubbles with no significant difference between the groups ( p=0.8065). Conclusion A comparable prevalence of microbubbles between mechanochemical abaltion and radiofrequency ablation both of which are lower than that previously reported for ultrasound-guided foam sclerotherapy suggests that mechanochemical abaltion may not confer the same risk of neurological events as ultrasound-guided foam sclerotherapy for treatment of varicose veins.

  15. Discerning cultural identification from a thinly sliced behavioral sample.

    Science.gov (United States)

    Hamamura, Takeshi; Li, Liman Man Wai

    2012-12-01

    This research examined whether individual differences in cultural identification can be discerned at zero acquaintance. This issue was examined in Hong Kong, where the idiosyncrasy of cultural identification is a salient social-psychological issue. The participants were able to perceive accurately the targets' identification with Western culture from a video clip and from a still image. Findings also indicated that a stereotype of Western cultural identity (i.e., extraversion and particular hairstyle) facilitated these perceptions. Specifically, (a) the participants with a stronger stereotype were more accurate in perceiving Western cultural identification, (b) the targets who were experimentally manipulated to appear extraverted were rated as more strongly identifying with Western culture, and (c) the participants relatively unfamiliar with these stereotypes did not correctly perceive Western cultural identification. Implications of these findings on research on multiculturalism are also discussed.

  16. Efficacy of inferior turbinoplasty with the use of CO(2) laser, radiofrequency, and electrocautery.

    Science.gov (United States)

    Prokopakis, Emmanuel P; Koudounarakis, Eleftherios I; Velegrakis, George A

    2014-01-01

    Inferior turbinate surgery is one of the most commonly performed methods for the treatment of rhinitis symptoms, especially nasal obstruction. This is a comparative study of CO2 laser, electrocautery, and radiofrequency turbinoplasty in the treatment of rhinitis symptoms. From 1994 to 2011, 3219 patients were enrolled in the study. Two hundred eighty-three patients were lost during follow-.up. Of the remaining 2936 patients, 1066 were managed using the CO2 laser, whereas 664 and 1206 were managed with the use of radiofrequency and electrocautery, respectively. All procedures were performed under local anesthesia. Patients were asked to evaluate their symptoms with the visual analog scale (VAS) preoperatively, as well as 1 month and 1 year postoperatively. Rhinomanometry was used to objectively evaluate the effect on nasal obstruction. Mean VAS values preoperatively, regarding nasal obstruction, were 7.43 ± 0.96, 7.33 ± 0.87, and 7.64 ± 0.95 in the CO2 laser, radiofrequency, and electrocautery group, respectively. One month postoperatively, the score was significantly improved in all groups (CO2 laser, 3.44 ± 0.99; radiofrequency, 3.26 ± 0.76; electrocautery, 3.19 ± 0.79), which was almost stable in the 1st year of follow-up. Similar results were also observed in the evaluation of sneezing and rhinorrhea. Outcome did not statistically differ between the three methods. The CO2 laser, radiofrequency and electrocautery offer excellent postoperative results in turbinoplasty cases under local anesthesia.

  17. Use of Radiofrequency Ablation in Benign Thyroid Nodules: A Literature Review and Updates

    OpenAIRE

    Wong, KP; Lang, HHB

    2013-01-01

    Successful thermal ablation using radiofrequency has been reported in various tumors including liver or kidney tumors. Nonsurgical minimally invasive ablative therapy such as radiofrequency ablation (RFA) has been reported to be a safe and efficient treatment option in managing symptomatic cold thyroid nodules or hyperfunctioning thyroid nodules. Pressure and cosmetic symptoms have been shown to be significantly improved both in the short and long terms after RFA. For hyperfunctioning thyroid...

  18. Length of Barrett's segment predicts failure of eradication in radiofrequency ablation for Barrett's esophagus: a retrospective cohort study.

    Science.gov (United States)

    Luckett, Tyler; Allamneni, Chaitanya; Cowley, Kevin; Eick, John; Gullick, Allison; Peter, Shajan

    2018-05-21

    We aim to investigate factors that may contribute to failure of eradication of dysplastic Barrett's Esophagus among patients undergoing radiofrequency ablation treatment. A retrospective review of patients undergoing radiofrequency ablation for treatment of Barrett's Esophagus was performed. Data analyzed included patient demographics, medical history, length of Barrett's Esophagus, number of radiofrequency ablation sessions, and histopathology. Subsets of patients achieving complete eradication were compared with those not achieving complete eradication. A total of 107 patients underwent radiofrequency ablation for Barrett's Esophagus, the majority white, overweight, and male. Before treatment, 63 patients had low-grade dysplasia, and 44 patients had high-grade dysplasia or carcinoma. Complete eradication was achieved in a majority of patients (57% for metaplasia, and 76.6% for dysplasia). Failure of eradication occurred in 15.7% of patients. The median number of radiofrequency ablation treatments in patients achieving complete eradication was 3 sessions, compared to 4 sessions for failure of eradication (p = 0.06). Barrett's esophagus length of more than 5 cm was predictive of failure of eradication (p Radiofrequency ablation for dysplastic Barrett's Esophagus is a proven and effective treatment modality, associated with a high rate of complete eradication. Our rates of eradication from a center starting an ablation program are comparable to previously published studies. Length of Barrett's segment > 5 cm was found to be predictive of failure of eradication in patients undergoing radiofrequency ablation.

  19. Treatment of Décolletage Photoaging With Fractional Microneedling Radiofrequency.

    Science.gov (United States)

    Lyons, Alexis; Roy, Jillian; Herrmann, Jennifer; Chipps, Lisa

    2018-01-01

    The objective of this study was to examine the efficacy and safety of a novel fractional microneedling radiofrequency device to improve the appearance of rhytides and skin laxity of the décolletage. Twelve subjects received a total of three fractional microneedling radiofrequency treatments with Endymed Intensif (EndyMed Ltd., Cesarea, Israel) at least three weeks apart. Primary outcome measure was clinical efficacy quantified by a patient survey to assess treatment satisfaction as well as a physician Global Aesthetic Improvement Scale (GAIS). Photos were taken before every treatment and at a follow-up appointment. Assessments by two board-certified dermatologists revealed an overall improvement in 67% of patients. Seventy percent of subjects rated their post-treatment skin laxity and rhytides as improved, while 60% of patients rated their skin texture as improved. Eighty percent of subjects were at least slightly satisfied with their treatment. Forty percent of subjects would recommend this treatment to others. Subjects in this study demonstrated an overall improvement in décolletage appearance in regard to skin tightening, wrinkles, and skin texture suggested by overall patient satisfaction (80%) and physician-rated GAIS improvement (67%). This study suggests that fractional microneedling radiofrequency devices are a safe and efficacious way to improve overall décolletage appearance with little down time. J Drugs Dermatol. 2018;17(1):74-76..

  20. Radiofrequency radiation

    International Nuclear Information System (INIS)

    Elder, J.A.; Czerski, P.A.; Stuchly, M.A.; Mild, K.H.; Sheppard, A.R.

    1989-01-01

    High-level radiofrequency radiation is a source of thermal energy that carries all of the known implications of heating for biological systems, including burns, temporary and permanent changes in reproduction, cataracts, and death. In general, no changes in chromosomes, DNA or the reproductive potential of animals exposed to RF radiation have been reported in the absence of significant rises in temperature, though there are limited data on DNA and chromosomal changes at non-thermal levels. Human data are currently limited and do not provide adequate information about the relationship between prolonged low-level RF radiation exposure and increased mortality or morbidity, including cancer incidence. In epidemiological studies and clinical reports of RF effects in man, the problems of quantification are numerous and include uncertainties about ''dose'', health effects, latent periods, dose-response relationships, and interactions with other physical or chemical agents. 228 refs, 6 figs, 2 tabs

  1. Mitral valve perforation appearing years after radiofrequency ablation

    DEFF Research Database (Denmark)

    Fisch-Thomsen, Marie; Jensen, Jesper K; Egeblad, Henrik

    2011-01-01

    The case is reported of a young adult with Wolff-Parkinson-White (WPW) syndrome who, three years after a complicated radiofrequency (RF) catheter ablation procedure, developed dyspnea on exertion. Echocardiography revealed severe mitral valve regurgitation caused by a perforation of the posterior...

  2. Radiofrequency solutions in clinical high field magnetic resonance

    NARCIS (Netherlands)

    Andreychenko, A.

    2013-01-01

    Magnetic resonance imaging (MRI) and spectroscopy (MRS) benefit from the sensitivity gain at high field (≥7T). However, high field brings also certain challenges associated with growing frequency and spectral dispersion. Frequency growth results in degraded performance of large volume radiofrequency

  3. Endovascular ultrasound for renal sympathetic denervation in patients with therapy-resistant hypertension not responding to radiofrequency renal sympathetic denervation.

    Science.gov (United States)

    Stiermaier, Thomas; Okon, Thomas; Fengler, Karl; Mueller, Ulrike; Hoellriegel, Robert; Schuler, Gerhard; Desch, Steffen; Lurz, Philipp

    2016-06-12

    Recent studies have reported a considerable number of non-responders after renal sympathetic de-nervation (RSD) with radiofrequency technology. Here we report our results of repeat RSD using ultrasound in these patients. A cohort study was performed in patients who underwent ultrasound RSD after non-response to RSD with radiofrequency. Non-response was defined as mean daytime systolic blood pressure ≥140 mmHg and/or a reduction of ≤10 mmHg in ambulatory blood pressure measurement (ABPM) ≥6 months after radiofrequency denervation. ABPM was recorded at baseline, post radiofrequency RSD as well as at three and six months post ultrasound RSD. A total of 24 non-responders underwent retreatment with the ultrasound device at a mean 15.3±8.2 months after radiofrequency RSD. Ultrasound RSD was performed successfully in all patients without severe adverse events. Mean daytime systolic blood pressure changed from 161.7±14.6 mmHg at baseline to 158.5±9.5 mmHg post radiofrequency RSD and to 150.5±10.4 mmHg and 151.6±11.0 mmHg at three and six months, respectively, post ultrasound RSD (pmeasures analysis of variance). The main results of post hoc testing were as follows: baseline versus post radiofrequency RSD, p=0.83; baseline versus three months post ultrasound RSD, p=0.01; and baseline versus six months post ultrasound RSD, p=0.04. Ultrasound RSD appears to be safe and an effective therapeutic approach in patients not responding to previous RSD with radiofrequency technology.

  4. Comparison of QuadrapolarTM radiofrequency lesions produced by standard versus modified technique: an experimental model

    Directory of Open Access Journals (Sweden)

    Safakish R

    2017-06-01

    Full Text Available Ramin Safakish Allevio Pain Management Clinic, Toronto, ON, Canada Abstract: Lower back pain (LBP is a global public health issue and is associated with substantial financial costs and loss of quality of life. Over the years, different literature has provided different statistics regarding the causes of the back pain. The following statistic is the closest estimation regarding our patient population. The sacroiliac (SI joint pain is responsible for LBP in 18%–30% of individuals with LBP. Quadrapolar™ radiofrequency ablation, which involves ablation of the nerves of the SI joint using heat, is a commonly used treatment for SI joint pain. However, the standard Quadrapolar radiofrequency procedure is not always effective at ablating all the sensory nerves that cause the pain in the SI joint. One of the major limitations of the standard Quadrapolar radiofrequency procedure is that it produces small lesions of ~4 mm in diameter. Smaller lesions increase the likelihood of failure to ablate all nociceptive input. In this study, we compare the standard Quadrapolar radiofrequency ablation technique to a modified Quadrapolar ablation technique that has produced improved patient outcomes in our clinic. The methodology of the two techniques are compared. In addition, we compare results from an experimental model comparing the lesion sizes produced by the two techniques. Taken together, the findings from this study suggest that the modified Quadrapolar technique provides longer lasting relief for the back pain that is caused by SI joint dysfunction. A randomized controlled clinical trial is the next step required to quantify the difference in symptom relief and quality of life produced by the two techniques. Keywords: lower back pain, radiofrequency ablation, sacroiliac joint, Quadrapolar radiofrequency ablation

  5. Detection and identification of Leishmania spp.: application of two hsp70-based PCR-RFLP protocols to clinical samples from the New World.

    Science.gov (United States)

    Montalvo, Ana M; Fraga, Jorge; Tirado, Dídier; Blandón, Gustavo; Alba, Annia; Van der Auwera, Gert; Vélez, Iván Darío; Muskus, Carlos

    2017-07-01

    Leishmaniasis is highly prevalent in New World countries, where several methods are available for detection and identification of Leishmania spp. Two hsp70-based PCR protocols (PCR-N and PCR-F) and their corresponding restriction fragment length polymorphisms (RFLP) were applied for detection and identification of Leishmania spp. in clinical samples recruited in Colombia, Guatemala, and Honduras. A total of 93 cases were studied. The samples were classified into positive or suspected of leishmaniasis according to parasitological criteria. Molecular amplification of two different hsp70 gene fragments and further RFLP analysis for identification of Leishmania species was done. The detection in parasitologically positive samples was higher using PCR-N than PCR-F. In the total of samples studied, the main species identified were Leishmania panamensis, Leishmania braziliensis, and Leishmania infantum (chagasi). Although RFLP-N was more efficient for the identification, RFLP-F is necessary for discrimination between L. panamensis and Leishmania guyanesis, of great importance in Colombia. Unexpectedly, one sample from this country revealed an RFLP pattern corresponding to Leishmania naiffi. Both molecular variants are applicable for the study of clinical samples originated in Colombia, Honduras, and Guatemala. Choosing the better tool for each setting depends on the species circulating. More studies are needed to confirm the presence of L. naiffi in Colombian territory.

  6. Complications associated with radiofrequency ablation of pulmonary veins.

    Science.gov (United States)

    Madrid Pérez, J M; García Barquín, P M; Villanueva Marcos, A J; García Bolao, J I; Bastarrika Alemañ, G

    Radiofrequency ablation is an efficacious alternative in patients with symptomatic atrial fibrillation who do not respond to or are intolerant to at least one class I or class III antiarrhythmic drug. Although radiofrequency ablation is a safe procedure, complications can occur. Depending on the location, these complications can be classified into those that affect the pulmonary veins themselves, cardiac complications, extracardiac intrathoracic complications, remote complications, and those that result from vascular access. The most common complications are hematomas, arteriovenous fistulas, and pseudoaneurysms at the puncture site. Some complications are benign and transient, such as gastroparesis or diaphragmatic elevation, whereas others are potentially fatal, such as cardiac tamponade. Radiologists must be familiar with the complications that can occur secondary to pulmonary vein ablation to ensure early diagnosis and treatment. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories.

    Science.gov (United States)

    Wallin, Olof; Söderberg, Johan; Van Guelpen, Bethany; Stenlund, Hans; Grankvist, Kjell; Brulin, Christine

    2010-09-01

    Scand J Caring Sci; 2010; 24; 581-591 
 Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories   Most errors in venous blood testing result from human mistakes occurring before the sample reach the laboratory.   To survey venous blood sampling (VBS) practices in hospital wards and to compare practices with hospital laboratories.   Staff in two hospitals (all wards) and two hospital laboratories (314 respondents, response rate 94%), completed a questionnaire addressing issues relevant to the collection of venous blood samples for clinical chemistry testing.   The findings suggest that instructions for patient identification and the collection of venous blood samples were not always followed. For example, 79% of the respondents reported the undesirable practice (UDP) of not always using wristbands for patient identification. Similarly, 87% of the respondents noted the UDP of removing venous stasis after the sampling is finished. Compared with the ward staff, a significantly higher proportion of the laboratory staff reported desirable practices regarding the collection of venous blood samples. Neither education nor the existence of established sampling routines was clearly associated with VBS practices among the ward staff.   The results of this study, the first of its kind, suggest that a clinically important risk of error is associated with VBS in the surveyed wards. Most important is the risk of misidentification of patients. Quality improvement of blood sample collection is clearly needed, particularly in hospital wards. © 2009 The Authors. Journal compilation © 2009 Nordic College of Caring Science.

  8. A hybrid polarization-selective atomic sensor for radio-frequency field detection with a passive resonant-cavity field amplifier

    OpenAIRE

    Anderson, David A.; Paradis, Eric G.; Raithel, Georg

    2018-01-01

    We present a hybrid atomic sensor that realizes radio-frequency electric field detection with intrinsic field amplification and polarization selectivity for robust high-sensitivity field measurement. The hybrid sensor incorporates a passive resonator element integrated with an atomic vapor cell that provides amplification and polarization selectivity for detection of incident radio-frequency fields. The amplified intra-cavity radio-frequency field is measured by atoms using a quantum-optical ...

  9. Endoscopic release of congenital muscular torticollis with radiofrequency in teenagers.

    Science.gov (United States)

    Wang, Jun-Liang; Qi, Wei; Liu, Yu-Jie

    2018-05-03

    Congenital muscular torticollis (CMT) is due to contracture of the sternocleidomastoid muscle which may cause activity limitations of the neck, tilt of the head, craniofacial asymmetry, and deformity of the skull. The authors present their experience of arthroscopic tight fibrous band release with radiofrequency in teenagers under local anesthesia and evaluate the clinical results. A total of 69 patients who underwent arthroscopic release of CMT with radiofrequency under local anesthesia by a single surgeon could participate in this study. Before operation, surface landmarks of sternocleidomastoid muscle, bone, and neurovascular structures were marked. Local infiltrating anesthesia of the surgical region was then performed. Through a working space created by blunt dissection, the arthroscopy and radiofrequency devices were introduced. Then, the clavicular and sternal heads of the sternocleidomastoid muscle were identified and gradually transected. The patients were followed up postoperatively with Cheng's scoring system. There were 31 male patients and 38 female patients. The mean age of the patients was 16.1 years. The mean length of follow-up in this series was 36.7 months (range, 28 to 67 months). During the operation, 62 patients (89.9%) had no pain, 6 patients (8.7%) felt mild pain, and only 1 patient (1.4%) regarded the procedure as very painful. At all follow-up periods, there were no repeat arthroscopies for any of these patients. At the final follow-up, the average rotation deficit improved from 22.5° to 4.1° postoperatively, and the average lateral bending deficit improved from 14.6° to 3.3° (p radiofrequency under local anesthesia provides surgeons with an alternative to traditional open techniques for the management of congenital muscular torticollis (CMT). Our date shows that this method is minimally invasive and provides good functional recovery with a lower risk of complications.

  10. Measurement of intrahepatic pressure during radiofrequency ablation in porcine liver.

    Science.gov (United States)

    Kawamoto, Chiaki; Yamauchi, Atsushi; Baba, Yoko; Kaneko, Keiko; Yakabi, Koji

    2010-04-01

    To identify the most effective procedures to avoid increased intrahepatic pressure during radiofrequency ablation, we evaluated different ablation methods. Laparotomy was performed in 19 pigs. Intrahepatic pressure was monitored using an invasive blood pressure monitor. Radiofrequency ablation was performed as follows: single-step standard ablation; single-step at 30 W; single-step at 70 W; 4-step at 30 W; 8-step at 30 W; 8-step at 70 W; and cooled-tip. The array was fully deployed in single-step methods. In the multi-step methods, the array was gradually deployed in four or eight steps. With the cooled-tip, ablation was performed by increasing output by 10 W/min, starting at 40 W. Intrahepatic pressure was as follows: single-step standard ablation, 154.5 +/- 30.9 mmHg; single-step at 30 W, 34.2 +/- 20.0 mmHg; single-step at 70 W, 46.7 +/- 24.3 mmHg; 4-step at 30 W, 42.3 +/- 17.9 mmHg; 8-step at 30 W, 24.1 +/- 18.2 mmHg; 8-step at 70 W, 47.5 +/- 31.5 mmHg; and cooled-tip, 114.5 +/- 16.6 mmHg. The radiofrequency ablation-induced area was spherical with single-step standard ablation, 4-step at 30 W, and 8-step at 30 W. Conversely, the ablated area was irregular with single-step at 30 W, single-step at 70 W, and 8-step at 70 W. The ablation time was significantly shorter for the multi-step method than for the single-step method. Increased intrahepatic pressure could be controlled using multi-step methods. From the shapes of the ablation area, 30-W 8-step expansions appear to be most suitable for radiofrequency ablation.

  11. Simplified method for esophagus protection during radiofrequency catheter ablation of atrial fibrillation - prospective study of 704 cases

    Science.gov (United States)

    Mateos, José Carlos Pachón; Mateos, Enrique I Pachón; Peña, Tomas G Santillana; Lobo, Tasso Julio; Mateos, Juán Carlos Pachón; Vargas, Remy Nelson A; Pachón, Carlos Thiene C; Acosta, Juán Carlos Zerpa

    2015-01-01

    Introduction Although rare, the atrioesophageal fistula is one of the most feared complications in radiofrequency catheter ablation of atrial fibrillation due to the high risk of mortality. Objective This is a prospective controlled study, performed during regular radiofrequency catheter ablation of atrial fibrillation, to test whether esophageal displacement by handling the transesophageal echocardiography transducer could be used for esophageal protection. Methods Seven hundred and four patients (158 F/546M [22.4%/77.6%]; 52.8±14 [17-84] years old), with mean EF of 0.66±0.8 and drug-refractory atrial fibrillation were submitted to hybrid radiofrequency catheter ablation (conventional pulmonary vein isolation plus AF-Nests and background tachycardia ablation) with displacement of the esophagus as far as possible from the radiofrequency target by transesophageal echocardiography transducer handling. The esophageal luminal temperature was monitored without and with displacement in 25 patients. Results The mean esophageal displacement was 4 to 9.1cm (5.9±0.8 cm). In 680 of the 704 patients (96.6%), it was enough to allow complete and safe radiofrequency delivery (30W/40ºC/irrigated catheter or 50W/60ºC/8 mm catheter) without esophagus overlapping. The mean esophageal luminal temperature changes with versus without esophageal displacement were 0.11±0.13ºC versus 1.1±0.4ºC respectively, P<0.01. The radiofrequency had to be halted in 68% of the patients without esophageal displacement because of esophageal luminal temperature increase. There was no incidence of atrioesophageal fistula suspected or confirmed. Only two superficial bleeding caused by transesophageal echocardiography transducer insertion were observed. Conclusion Mechanical esophageal displacement by transesophageal echocardiography transducer during radiofrequency catheter ablation was able to prevent a rise in esophageal luminal temperature, helping to avoid esophageal thermal lesion. In most

  12. Administrative norms on radiofrequency radiation for occupationally exposed persons

    International Nuclear Information System (INIS)

    Saxeboel, G.

    1982-01-01

    The report presents a proposal for administrative norms on radiofrequency (RF) radiation for occupationally exposed persons. The norms establish maximum allowable field exposure in a frequency range from 1 MHz too 300 GHz. (RF)

  13. Bilateral occipital lobe infarction with altitudinal field loss following radiofrequency cardiac catheter ablation

    Directory of Open Access Journals (Sweden)

    Chen Celia S

    2010-03-01

    Full Text Available Abstract Background Bilateral stroke following radiofrequency catheter ablation is an unusual complication and may result in bilateral altitudinal visual field defects. Bilateral altitudinal visual field defects usually result from prechiasmal pathology causing damage to both retinas or optic nerves and rarely from bilateral symmetric damage to the post chiasmal visual pathways. Case presentation A 48-year-old man complained of visual disturbance on wakening following radiofrequency catheter ablation. The patient had a CHADS score of 1 pre-operatively and no complications were noted intra-operatively. Examination revealed a bilateral superior altitudinal defect and MRI of the brain showed multifocal areas of infarction predominantly involving the occipital lobes which correlated to with the visual deficits. Conclusion While the risk of thromboembolism and perioperative stroke during radiofrequency catheter ablation is small, it is not insignificant.

  14. Neurohumoral indicators of efficacy radiofrequency cardiac denervation

    Energy Technology Data Exchange (ETDEWEB)

    Evtushenko, A. V., E-mail: ave@cardio-tomsk.ru; Evtushenko, V. V. [National Research Tomsk State University, Tomsk (Russian Federation); Federal State Budgetary Scientific Institution “Research Institute for Cardiology”, Tomsk (Russian Federation); Saushkina, Yu. V.; Gusakova, A. M.; Suslova, T. E.; Dymbrylova, O. N.; Smyshlyaev, K. A.; Kurlov, I. O. [Federal State Budgetary Scientific Institution “Research Institute for Cardiology”, Tomsk (Russian Federation); Lishmanov, Yu. B.; Anfinogenova, Ya. D. [National Research Tomsk Polytechnic University, Tomsk (Russian Federation); Federal State Budgetary Scientific Institution “Research Institute for Cardiology”, Tomsk (Russian Federation); Sergeevichev, D. S. [Academician E.N. Meshalkin State Research Institute of Circulation Pathology, Novosibirsk (Russian Federation); Bykov, A. N.; Syryamkin, V. I.; Kistenev, Yu. V. [National Research Tomsk State University, Tomsk (Russian Federation); Lotkov, A. I. [Institute of Strength Physics and Materials Science of the Siberian Branch of the RAS, Tomsk (Russian Federation); Pokushalov, E. A.

    2015-11-17

    In this study, we compared pre- and postoperative parameters of the cardiac sympathetic innervation. The aim of the study was to examine the approaches to evaluating the quality of radiofrequency (RF)-induced cardiac denervation by using non-invasive and laboratory methods. The study included 32 people with long-lasting persistent atrial fibrillation (AF). The patients were divided into 2 groups according to the objectives of the study: group 1 (main) - 21 patients with mitral valve diseases, which simultaneously with radiofrequency ablation (RFA) AF carried out on the effects of the paraganglionic nervous plexuses by C. Pappone (2004) and N. Doll (2008) schemes. The second group (control) contained 11 patients with heart diseases in sinus rhythm (the RF denervation not been performed). All patients, who underwent surgical treatment, were received examination of cardiac sympathetic tone by using {sup 123}I-MIBG. All of them made blood analysis from ascending aorta and coronary sinus to determine the level of norepinephrine and its metabolites before and after cardiac denervation. Data of radionuclide examination are correlating with laboratory data.

  15. Health Impacts Of Radiofrequency Exposure From Mobile Phone ...

    African Journals Online (AJOL)

    Background: The widespread use of mobile phones and indiscriminate siting of transmitter base stations near residential buildings in our environment may have serious health impacts. Objective: To investigate the possible health risks associated with radiofrequency (RF) exposure from mobile phones and other transmitter ...

  16. Poloidally asymmetric potential increases in tokamak scrape-off layer plasmas by radiofrequency power

    International Nuclear Information System (INIS)

    Diebold, D.A.; Majeski, R.; Tanaka, T.

    1992-01-01

    Langmuir probe data are presented which show poloidally asymmetric increases in floating potential, electron temperature and, hence, plasma potential on magnetic field lines which map to the Faraday shield of an ICRF antenna in a medium size tokamak, Phaedrus-T, during radiofrequency power injection. These data are consistent with and suggestive of the existence of radiofrequency generated sheath voltages on those field lines. (author). Letter-to-the-editor. 20 refs, 3 figs

  17. Non-destructive radio-frequency and microwave measurement of moisture content in agricultural commodities

    International Nuclear Information System (INIS)

    Nelson, S.O.

    1994-01-01

    The importance of moisture content in agricultural commodities, the usefulness of the dielectric properties of such products for sensing moisture content by radiofrequency and microwave measurements, and factors affecting these properties are briefly discussed. Recent developments in the understanding of principles for online moisture sensing and the sensing of individual kernel, seed, nut and fruit moisture contents by radiofrequency and microwave techniques are reviewed. A brief discussion is included on aspects of practical application

  18. Arrhythmia-free survival and pulmonary vein reconnection patterns after second-generation cryoballoon and contact-force radiofrequency pulmonary vein isolation.

    Science.gov (United States)

    Buist, Thomas J; Adiyaman, Ahmet; Smit, Jaap Jan J; Ramdat Misier, Anand R; Elvan, Arif

    2018-06-01

    The aim of this study was to compare second-generation cryoballoon and contact-force radiofrequency point-by-point pulmonary vein isolation (PVI) in atrial fibrillation (AF) patients with regard to pulmonary vein reconnection and arrhythmia-free survival. Altogether, 269 consecutive patients with drug-refractory AF undergoing PVI were included and randomly allocated to second-generation cryoballoon or contact-force point-by-point radiofrequency ablation. Median follow-up duration was 389 days (interquartile range 219-599). Mean age was 59 years (71% male); 136 patients underwent cryoballoon and 133 patients underwent radiofrequency ablation. Acute electrical PVI was 100% for both techniques. Procedure duration was significantly shorter in cryoballoon vs radiofrequency (166.5 vs 184.13 min P = 0.016). Complication rates were similar (6.0 vs 6.7%, P = 1.00). Single procedure freedom of atrial arrhythmias was significantly higher in cryoballoon as compared to radiofrequency (75.2 vs 57.4%, P = 0.013). In multivariate analysis, persistent AF, AF duration, and cryoballoon ablation were associated with freedom of atrial tachyarrhythmias. The number of repeat ablation procedures was significantly lower in the cryoballoon compared to radiofrequency (15.0 vs 24.3%, P = 0.045). At repeat ablation, pulmonary vein reconnection rate was significantly lower after cryoballoon as compared to radiofrequency ablation (36.8 vs 58.1%, P = 0.003). Improved arrhythmia-free survival and more durable pulmonary vein isolation is seen after PVI using second-generation cryoballoon as compared to contact-force radiofrequency, in patients with drug-refractory paroxysmal AF. Complication rates for both ablation techniques are low.

  19. Identification of herbarium whole-leaf samples of Epilobium species by ATR-IR spectroscopy.

    Science.gov (United States)

    Strgulc Krajsek, Simona; Buh, Primoz; Zega, Anamarija; Kreft, Samo

    2008-02-01

    A simple, high-accuracy FT-IR method based on attenuated total reflection (ATR) was developed for the rapid determination of leaf samples of Epilobium species. The method is superior to other analytical techniques, since there is no need of laborious sample preparation such as grinding or extraction and solvent removal. A total of 70 herbarium specimens, belonging to all 13 Epilobium and to 2 Chamerion species growing in Slovenia, were analyzed. With the 100 most-informative wavenumbers in the range 700-1800 cm(-1), we obtained over 90% accuracy of species identification, with discriminant multivariate statistical analysis on the measurements made on whole dried leaves.

  20. Effect of Mobile Phone Radiofrequency Electromagnetic Fields on ...

    African Journals Online (AJOL)

    Summary: Since cell phones emit radiofrequency electromagnetic fields (EMFs), this study tested the hypothesis that cell phones placed near the heart may interfere with the electrical rhythm of the heart or affect the blood pressure. Following informed consent, eighteen randomly selected apparently healthy male volunteers ...

  1. [Patient identification errors and biological samples in the analytical process: Is it possible to improve patient safety?].

    Science.gov (United States)

    Cuadrado-Cenzual, M A; García Briñón, M; de Gracia Hills, Y; González Estecha, M; Collado Yurrita, L; de Pedro Moro, J A; Fernández Pérez, C; Arroyo Fernández, M

    2015-01-01

    Patient identification errors and biological samples are one of the problems with the highest risk factor in causing an adverse event in the patient. To detect and analyse the causes of patient identification errors in analytical requests (PIEAR) from emergency departments, and to develop improvement strategies. A process and protocol was designed, to be followed by all professionals involved in the requesting and performing of laboratory tests. Evaluation and monitoring indicators of PIEAR were determined, before and after the implementation of these improvement measures (years 2010-2014). A total of 316 PIEAR were detected in a total of 483,254 emergency service requests during the study period, representing a mean of 6.80/10,000 requests. Patient identification failure was the most frequent in all the 6-monthly periods assessed, with a significant difference (Perrors. However, we must continue working with this strategy, promoting a culture of safety for all the professionals involved, and trying to achieve the goal that 100% of the analytical and samples are properly identified. Copyright © 2015 SECA. Published by Elsevier Espana. All rights reserved.

  2. Radiofrequency power deposition during magnetic resonance diagnostic examinations

    International Nuclear Information System (INIS)

    Grandolfo, M.; Vecchia, P.

    1988-01-01

    Magnetic Resonance Imaging and Spectroscopy (MRI, MRS) require that subjects be exposed to radiofrequency field, and the corresponding energy absorption leads to tissue heating. The main question, thus, to be considered in connection to safety and health aspects is related to the specific absorption rate (SAR) in the imaged subject and the exposure durations which might put a practical limit on the pulse sequence which can be used. In this paper some models and experimental results for radiofrequency power deposition in MRI and MRS machines are reviewed. Models show that energy dissipation is a function of the frequency, RF incident power density, exposure duration, coupling between the RF coil and the subject, and several properties of the exposed tissue, including conductivity, dielectric constant, specific gravity, size, and orientation relative to the field polarization. The ability of the body's normal thermoregulatory responses to cope with high levels of RF energy deposition must be also taken into account

  3. Process for selected gas oxide removal by radiofrequency catalysts

    Science.gov (United States)

    Cha, Chang Y.

    1993-01-01

    This process to remove gas oxides from flue gas utilizes adsorption on a char bed subsequently followed by radiofrequency catalysis enhancing such removal through selected reactions. Common gas oxides include SO.sub.2 and NO.sub.x.

  4. Radiofrequency in cosmetic dermatology.

    Science.gov (United States)

    Beasley, Karen L; Weiss, Robert A

    2014-01-01

    The demand for noninvasive methods of facial and body rejuvenation has experienced exponential growth over the last decade. There is a particular interest in safe and effective ways to decrease skin laxity and smooth irregular body contours and texture without downtime. These noninvasive treatments are being sought after because less time for recovery means less time lost from work and social endeavors. Radiofrequency (RF) treatments are traditionally titrated to be nonablative and are optimal for those wishing to avoid recovery time. Not only is there minimal recovery but also a high level of safety with aesthetic RF treatments. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Prospective, pilot evaluation of the performance of nanofractional radiofrequency for improvement of skin texture via skin resurfacing.

    Science.gov (United States)

    Bohnert, Krista; Dorizas, Andrew; Sadick, Neil

    2018-02-01

    The latest generation of radiofrequency, nanofractional radiofrequency, allows the heat energy to be delivered through the use of pins or needles as electrodes, facilitating increased efficacy and reduced pain, downtime, and side effects. The objective of this prospective pilot clinical study was to evaluate the efficacy of nanofractional radiofrequency in skin resurfacing. Seventeen subjects were enrolled in the study, and each received three nanofractional radiofrequency (160-pin tip) treatments in the facial area at 3-week intervals. Follow-up visits were scheduled at 1 and 2 months after the final treatment. Clinical photography, patient, and investigator assessments were conducted during the treatment visits and follow-up. All subjects completed the study. At the 1- and 2-month follow-up, there was a moderate to significant improvement (2.6 and 3.5, respectively, P = .01) according to the investigator global esthetic improvement scale rating. Most subjects reported that they were satisfied or very satisfied with the outcome and level of comfort. Nanofractional radiofrequency is a safe and effective strategy for improving texture, tone, and skin laxity with high patient satisfaction and tolerable safety profile. © 2017 Wiley Periodicals, Inc.

  6. Adaptive Response in Animals Exposed to Non-Ionizing Radiofrequency Fields: Some Underlying Mechanisms

    Directory of Open Access Journals (Sweden)

    Yi Cao

    2014-04-01

    Full Text Available During the last few years, our research group has been investigating the phenomenon of adaptive response in animals exposed to non-ionizing radiofrequency fields. The results from several separate studies indicated a significant increase in survival, decreases in genetic damage as well as oxidative damage and, alterations in several cellular processes in mice pre-exposed to radiofrequency fields and subsequently subjected to sub-lethal or lethal doses of γ-radiation or injected with bleomycin, a radiomimetic chemical mutagen. These observations indicated the induction of adaptive response providing the animals the ability to resist subsequent damage. Similar studies conducted by independent researchers in mice and rats have supported our observation on increased survival. In this paper, we have presented a brief review of all of our own and other independent investigations on radiofrequency fields-induced adaptive response and some underlying mechanisms discussed.

  7. Percutaneous treatment of hepatocellular carcinoma in patients with cirrhosis: A comparison of the safety of cryoablation and radiofrequency ablation

    International Nuclear Information System (INIS)

    Dunne, Ruth M.; Shyn, Paul B.; Sung, Jeffrey C.; Tatli, Servet; Morrison, Paul R.; Catalano, Paul J.; Silverman, Stuart G.

    2014-01-01

    Purpose: To compare the safety of image-guided percutaneous cryoablation and radiofrequency ablation in the treatment of hepatocellular carcinoma in patients with cirrhosis. Materials and methods: This retrospective HIPAA-compliant study received institutional review board approval. Forty-two adult patients with cirrhosis underwent image-guided percutaneous ablation of hepatocellular carcinoma from 2003 to 2011. Twenty-five patients underwent 33 cryoablation procedures to treat 39 tumors, and 22 underwent 30 radiofrequency ablation procedures to treat 39 tumors. Five patients underwent both cryoablation and radiofrequency ablation procedures. Complication rates and severity per procedure were compared between the ablation groups. Potential confounding patient, procedure, and tumor-related variables were also compared. Statistical analyses included Kruskal–Wallis, Wilcoxon rank sum, and Fisher's exact tests. Two-sided P-values <0.05 were considered significant. Results: The overall complication rates, 13 (39.4%) of 33 cryoablation procedures versus eight (26.7%) of 30 radiofrequency ablation procedures and severe/fatal complication rates, two (6.1%) of 33 cryoablation procedures versus one (3.3%) of 30 radiofrequency ablation procedures, were not significantly different between the ablation groups (both P = 0.26). Severe complications included pneumothoraces requiring chest tube insertion during two cryoablation procedures. One death occurred within 90 days of a radiofrequency ablation procedure; all other complications were managed successfully. Conclusion: No significant difference was seen in the overall safety of image-guided percutaneous cryoablation and radiofrequency ablation in the treatment of hepatocellular carcinoma in patients with cirrhosis

  8. Treatment of Osteoid Osteomas Using a Navigational Bipolar Radiofrequency Ablation System

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, Adam N., E-mail: wallacea@mir.wustl.edu; Tomasian, Anderanik, E-mail: tomasiana@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States); Chang, Randy O., E-mail: changr@wusm.wustl.edu [Washington University School of Medicine (United States); Jennings, Jack W., E-mail: jenningsj@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States)

    2016-05-15

    BackgroundPercutaneous CT-guided radiofrequency ablation is a safe and effective minimally invasive treatment for osteoid osteomas. This technical case series describes the use of a recently introduced ablation system with a probe that can be curved in multiple directions, embedded thermocouples for real-time monitoring of the ablation volume, and a bipolar design that obviates the need for a grounding pad.MethodsMedical records of all patients who underwent radiofrequency ablation of an osteoid osteoma with the STAR Tumor Ablation System (DFINE; San Jose, CA) were reviewed. The location of each osteoid osteoma, nidus volume, and procedural details were recorded. Treatment efficacy and long-term complications were assessed at clinical follow-up.ResultsDuring the study period, 18 osteoid osteomas were radiofrequency ablated with the multidirectional bipolar system. Lesion locations included the femur (50 %; 9/18), tibia (22 %; 4/18), cervical spine (11 %; 2/18), calcaneus (5.5 %; 1/18), iliac bone (5.5 %; 1/18), and fibula (5.5 %; 1/18). The median nidus volume of these cases was 0.33 mL (range 0.12–2.0 mL). All tumors were accessed via a single osseous channel. Median cumulative ablation time was 5 min and 0 s (range 1 min and 32 s–8 min and 50 s). All patients with clinical follow-up reported complete symptom resolution. No complications occurred.ConclusionSafe and effective CT-guided radiofrequency ablation of osteoid osteomas can be performed in a variety of locations using a multidirectional bipolar system.

  9. Treatment of Osteoid Osteomas Using a Navigational Bipolar Radiofrequency Ablation System

    International Nuclear Information System (INIS)

    Wallace, Adam N.; Tomasian, Anderanik; Chang, Randy O.; Jennings, Jack W.

    2016-01-01

    BackgroundPercutaneous CT-guided radiofrequency ablation is a safe and effective minimally invasive treatment for osteoid osteomas. This technical case series describes the use of a recently introduced ablation system with a probe that can be curved in multiple directions, embedded thermocouples for real-time monitoring of the ablation volume, and a bipolar design that obviates the need for a grounding pad.MethodsMedical records of all patients who underwent radiofrequency ablation of an osteoid osteoma with the STAR Tumor Ablation System (DFINE; San Jose, CA) were reviewed. The location of each osteoid osteoma, nidus volume, and procedural details were recorded. Treatment efficacy and long-term complications were assessed at clinical follow-up.ResultsDuring the study period, 18 osteoid osteomas were radiofrequency ablated with the multidirectional bipolar system. Lesion locations included the femur (50 %; 9/18), tibia (22 %; 4/18), cervical spine (11 %; 2/18), calcaneus (5.5 %; 1/18), iliac bone (5.5 %; 1/18), and fibula (5.5 %; 1/18). The median nidus volume of these cases was 0.33 mL (range 0.12–2.0 mL). All tumors were accessed via a single osseous channel. Median cumulative ablation time was 5 min and 0 s (range 1 min and 32 s–8 min and 50 s). All patients with clinical follow-up reported complete symptom resolution. No complications occurred.ConclusionSafe and effective CT-guided radiofrequency ablation of osteoid osteomas can be performed in a variety of locations using a multidirectional bipolar system.

  10. Pulmonary venous thrombosis secondary to radiofrequency ablation of the pulmonary veins.

    Science.gov (United States)

    López-Reyes, Raquel; García-Ortega, Alberto; Torrents, Ana; Feced, Laura; Calvillo, Pilar; Libreros-Niño, Eugenia Alejandra; Escrivá-Peiró, Juan; Nauffal, Dolores

    2018-01-01

    Pulmonary Vein Thrombosis (PVT) is a rare and underdiagnosed entity produced by local mechanical nature mechanisms, vascular torsion or direct injury to the vein. PVT has been described in clinical cases or small multicenter series mainly in relation to pulmonary vein stenosis, metastatic carcinoma, fibrosing mediastinitis, as an early surgical complication of lung transplantation lobectomy and radiofrequency ablation performed in patients with atrial fibrillation, although in some cases the cause is not known. We report the case of a 57 years old male with history of atrial fibrillation treated by radiofrequency ablation who was admitted in our center because of a two-week history of consistent pleuritic pain in the left hemithorax and low-grade hemoptysis and a lung consolidation treated as a pneumonia with antibiotic but not responding to medical therapy. In view of the poor evolution of the patient, computed tomography angiography was performed with findings of PVT and secondary venous infarction and anticoagulation therapy was optimized. At the end, pulmonary resection was performed due to hemorrhagic recurrence. PVT remains a rare complication of radiofrequency ablation and other procedures involving pulmonary veins. Clinical suspicion and early diagnosis is crucial because is a potentially life-threatening entity.

  11. Indication of the radiofrequency induced lesion size by pre-ablation measurements

    DEFF Research Database (Denmark)

    Stagegaard, Niels; Petersen, Helen Høgh; Chen, Xu

    2005-01-01

    BACKGROUND: During radiofrequency ablation of arrhythmias tissue heating and hence lesion size depend on electrode-tissue contact and cooling of the electrode tip caused by cavitary blood flow. These factors are unique and unknown for each catheter placement in the beating heart. A tool for asses......BACKGROUND: During radiofrequency ablation of arrhythmias tissue heating and hence lesion size depend on electrode-tissue contact and cooling of the electrode tip caused by cavitary blood flow. These factors are unique and unknown for each catheter placement in the beating heart. A tool...... for assessing these factors prior to ablation may indicate the lesion size which will be obtained for any given catheter position. METHODS AND RESULTS: Radiofrequency ablation was performed in vitro on strips of left ventricular porcine myocardium during two different levels of convective cooling (0 or 0.1 m....../s), two different contact pressures (10 or 30 g) and parallel or perpendicular electrode-tissue orientation using 7F 4 mm tip catheters. Prior to ablation the impedance rise (DeltaIMP) caused by the obtained contact and the temperature rise with a 0.6 W 5 s test pulse (DeltaT) were measured. Subsequently...

  12. Characterization of radiofrequency field emissions from smart meters.

    Science.gov (United States)

    Tell, Richard A; Kavet, Robert; Mezei, Gabor

    2013-01-01

    This study presents measurement data that describe radiofrequency emission levels and patterns from smart meters (rated nominally at 1 W) currently deployed in Pacific Gas and Electric Company's service territory in northern California. The smart meters in our investigation could not be set to operate continuously and required a Field Service Unit to induce short periods of emitted fields. To obtain peak field data under both laboratory and ambient conditions, a spectrum analyzer scanned across the 83 transmitting channels between 902 and 928 MHz used by the smart meter on a random frequency-hopping basis. To obtain data describing temporal emission patterns, the analyzer operated in scope mode. Duty cycle was estimated using transmit data acquired by the system operator from over 88,000 m. Instantaneous peak fields at 0.3 m in front of the meters were no more than 15% of the US Federal Communications Commission (FCC) exposure limit for the general public, and 99.9% of the meters operated with a duty cycle of 1.12% or less during the sampling period. In a sample of measurements in six single-detached residences equipped with individual smart meters, no interior measurement of peak field exceeded 1% of the FCC's general public exposure limit.

  13. Combined kinetic and transport modeling of radiofrequency current drive

    International Nuclear Information System (INIS)

    Dumont, R.; Giruzzi, G.; Barbato, E.

    2000-07-01

    A numerical model for predictive simulations of radiofrequency current drive in magnetically confined plasmas is developed. It includes the minimum requirements for a self consistent description of such regimes, i.e., a 3-D ,kinetic equation for the electron distribution function, 1-D heat and current transport equations, and resonant coupling between velocity space and configuration space dynamics, through suitable wave propagation equations. The model finds its full application in predictive studies of complex current profile control scenarios in tokamaks, aiming at the establishment of internal transport barriers by the simultaneous use of various radiofrequency current drive methods. The basic properties of this non-linear numerical system are investigated and illustrated by simulations applied to reversed magnetic shear regimes obtained by Lower Hybrid and Electron Cyclotron current drive for parameters typical of the Tore Supra tokamak. (authors)

  14. The Precautionary Principle in the Context of Mobile Phone and Base Station Radiofrequency Exposures

    OpenAIRE

    Dolan, Mike; Rowley, Jack

    2009-01-01

    Background No health hazard has been established from exposure to radiofrequency fields up to the levels recommended by the International Commission on Non-Ionizing Radiation Protection. However, in response to public concern and the perceived level of scientific uncertainty, there are continuing calls for the application of the precautionary principle to radiofrequency exposures from mobile phones and base stations. Objective We examined the international evolution of calls for precautionary...

  15. Noninvasive in vivo oximetric imaging by radiofrequency FT EPR

    NARCIS (Netherlands)

    Subramanian, S; Yamada, K; Irie, A; Murugesan, R; Cook, JA; Devasahayam, N; Van Dam, GM; Mitchell, JB; Krishna, MC

    A novel method, called relaxo-oximetry, for rapid spatially resolved in vivo measurements of oxygen concentration using time-domain radiofrequency (RF) electron paramagnetic resonance (EPR) is described. Time-domain data from triaryl methyl (TAM)-based single-electron contrast agents were processed

  16. Genetic identification of Iberian rodent species using both mitochondrial and nuclear loci: application to noninvasive sampling.

    Science.gov (United States)

    Barbosa, S; Pauperio, J; Searle, J B; Alves, P C

    2013-01-01

    Species identification through noninvasive sampling is increasingly used in animal conservation genetics, given that it obviates the need to handle free-living individuals. Noninvasive sampling is particularly valuable for elusive and small species such as rodents. Although rodents are not usually assumed to be the most obvious target for conservation, of the 21 species or near-species present in Iberia, three are considered endangered and declining, while several others are poorly studied. Here, we develop a genetic tool for identifying all rodent species in Iberia by noninvasive genetic sampling. To achieve this purpose, we selected one mitochondrial gene [cytochrome b (cyt-b)] and one nuclear gene [interphotoreceptor retinoid-binding protein (IRBP)], which we first sequenced using tissue samples. Both genes allow for the phylogenetic distinction of all species except the sibling species Microtus lusitanicus and Microtus duodecimcostatus. Overall, cyt-b showed higher resolution than IRBP, revealing a clear barcoding gap. To allow these markers to be applied to noninvasive samples, we selected a short highly diagnostic fragment from each gene, which we used to obtain sequences from faeces and bones from owl pellets. Amplification success for the cyt-b and IRBP fragment was 85% and 43% in faecal and 88% and 64% in owl-pellet DNA extractions, respectively. The method allows the unambiguous identification of the great majority of Iberian rodent species from noninvasive samples, with application in studies of distribution, spatial ecology and population dynamics, and for conservation. © 2012 Blackwell Publishing Ltd.

  17. Efficacy of percutaneous intraductal radiofrequency ablation combined with biliary stenting in treatment of malignant biliary obstruction

    Directory of Open Access Journals (Sweden)

    ZHANG Kai

    2015-05-01

    Full Text Available ObjectiveTo investigate the safety and feasibility of percutaneous intraductal radiofrequency ablation (palliative therapy in the treatment of malignant obstructive jaundice. MethodsThis study included 20 patients with unresectable malignant obstructive jaundice, who were treated in the First Affiliated Hospital of Zhengzhou University from January 2013 to March 2014. Nine of them (test group underwent percutaneous intraductal radiofrequency ablation plus metallic biliary stent placement. The other 11 similar cases (control group underwent metallic biliary stent placement alone after successful percutaneous transhepatic cholangiography. Operative complications and remission of jaundice were observed, and the stent patency after at 3 and 6 months after operation was evaluated and compared between the two groups. ResultsAll patients were followed completely by outpatient or telephone. The stent patency rate at 3 months after operation was 9/9 in the test group and 8/11 in the control group (χ2=2.888, P=0.218, and the stent patency rates at 6 months were 7/8 and 3/11, respectively (χ2=6.739, P=0.02. During follow-up, one case in the test group died of gastrointestinal bleeding at 113 d after operation; one case in the control group died of liver failure at 57 d after operation and one case died of disseminated intravascular coagulation at 142 d. ConclusionPercutaneous intraductal radiofrequency ablation is safe and feasible in the treatment of malignant biliary obstruction, and the preliminary efficacy in prolonging the patency of self-expanding metallic stent is satisfactory. However, this therapy needs to be further verified via large-sample randomized controlled studies.

  18. Benign thyroid nodule unresponsive to radiofrequency ablation treated with laser ablation: a case report.

    Science.gov (United States)

    Oddo, Silvia; Balestra, Margherita; Vera, Lara; Giusti, Massimo

    2018-05-11

    Radiofrequency ablation and laser ablation are safe and effective techniques for reducing thyroid nodule volume, neck symptoms, and cosmetic complaints. Therapeutic success is defined as a nodule reduction > 50% between 6 and 12 months after the procedure, but a percentage of nodules inexplicably do not respond to thermal ablation. We describe the case of a young Caucasian woman with a solid benign thyroid nodule who refused surgery and who had undergone radiofrequency ablation in 2013. The nodule did not respond in terms of either volume reduction or improvement in neck symptoms. After 2 years, given the patient's continued refusal of thyroidectomy, we proposed laser ablation. The nodule displayed a significant volume reduction (- 50% from radiofrequency ablation baseline volume, - 57% from laser ablation baseline), and the patient reported a significant improvement in neck symptoms (from 6/10 to 1/10 on a visual analogue scale). We conjecture that some benign thyroid nodules may be intrinsically resistant to necrosis when one specific ablation technique is used, but may respond to another technique. To the best of our knowledge, this is the first description of the effect of performing a different percutaneous ablation technique in a nodule that does not respond to radiofrequency ablation.

  19. IDENTIFICATION AND AUTHENTICATION OF DRY SAMPLES OF SOME MEDICINAL PLANTS USING LEAF EPIDERMAL FEATURES AS MARKER

    Directory of Open Access Journals (Sweden)

    Abdullahi Alanamu ABDULRAHAMAN

    2016-06-01

    Full Text Available Herbal medicine is the oldest and still the most widely used system of medicine in the world today and they are made exclusively from plants. However, most of these medicines or drugs are adulterated due to lack of proper identification of the plant samples. Method of checking adulteration of drug plants is the main focus of this study. The identification and authentication of dry samples of some medicinal plants were carried out using anatomical features. Twenty-five (25 plants materials were collected in Ibadan and Ilorin, Nigeria. The plants studied include Azardiracta indica, Newboudia leavis, Polyalthia longifolia, Cymbopogon citratus, Anarcardium occidentalis, Nicotiana tobbaccum, Jatropha curcas, Chromoleana odorata, Mangifera indica, Terminalia catappa, Ocimum gratisimum, Morus messosygia, Morinda lucida, Psidium guajava, Vitellaria paradoxa, Annona senegalensis, Vernonia amygdalina, Gliricidium sepium, Ravoulvia vomitora, Telferia occindentalis Citrus aurantifolia, C. limon, C. paradisi and C. sinensis. Leaf epidermal anatomy of these selected plants showed no major variations in stomatal complex types, frequency, size and shape of stomatal cells, epidermal cell wall and trichomes between fresh and dry samples. The variations that occur were between different species but not within species. Leaf epidermal anatomy, therefore, proved to be a significant tool for resolution of taxonomic confusion of dried samples of these plants.

  20. Radiofrequency assisted pancreaticoduodenectomy for palliative surgical resection of locally advanced pancreatic adenocarcinoma.

    Science.gov (United States)

    Kumar, Jayant; Reccia, Isabella; Sodergren, Mikael H; Kusano, Tomokazu; Zanellato, Artur; Pai, Madhava; Spalding, Duncan; Zacharoulis, Dimitris; Habib, Nagy

    2018-03-20

    Despite careful patient selection and preoperative investigations curative resection rate (R0) in pancreaticoduodenectomy ranges from 15% to 87%. Here we describe a new palliative approach for pancreaticoduodenectomy using a radiofrequency energy device to ablate tumor in situ in patients undergoing R1/R2 resections for locally advanced pancreatic ductal adenocarcinoma where vascular reconstruction was not feasible. There was neither postoperative mortality nor significant morbidity. Each time the ablation lasted less than 15 minutes. Following radiofrequency ablation it was observed that the tumor remnant attached to the vessel had shrunk significantly. In four patients this allowed easier separation and dissection of the ablated tumor from the adherent vessel leading to R1 resection. In the other two patients, the ablated tumor did not separate from vessel due to true tumor invasion and patients had an R2 resection. The ablated remnant part of the tumor was left in situ. Whenever pancreaticoduodenectomy with R0 resection cannot be achieved, this new palliative procedure could be considered in order to facilitate resection and enable maximum destruction in remnant tumors. Six patients with suspected tumor infiltration and where vascular reconstruction was not warranted underwent radiofrequency-assisted pancreaticoduodenectomy for locally advanced pancreatic ductal adenocarcinoma. Radiofrequency was applied across the tumor vertically 5-10 mm from the edge of the mesenteric and portal veins. Following ablation, the duodenum and the head of pancreas were removed after knife excision along the ablated line. The remaining ablated tissue was left in situ attached to the vessel.

  1. Radiofrequency and health. Expertise update. Opinion of the ANSES. Collective expertise report

    International Nuclear Information System (INIS)

    Cardis, Elisabeth; Dore, Jean-Francois; Marc-Vergnes, Jean-Pierre; Agnani, Jean-Benoit; Bruguiere, Pierre; Crouzier, David; Debaz, Josquin; Debuire, Brigitte; Deltour, Isabelle; LE Drean, Yves; Ledoigt, Gerard; Letertre, Thierry; Marchand, Dorothee; Massardier-Pilonchery, Amelie; Nadi, Mustapha; Pereira De Vasconcelos, Anne; Hours, Martine; Fite, Johanna; Merckel, Olivier; Roth, Olivia; Vergriette, Benoit; Saddoki, Sophia

    2013-10-01

    In a context of development of new technologies of wireless communications, and therefore of radio-electric signals used to transmit information, this voluminous document reports a detailed study on the effects of radiofrequency on health. It is notably based on a large literature survey and on an assessment of the level of proof of these effects by experts (proved, possible, probable, insufficiently proved, or no effect on mankind). These effects can be either biological or on health. The report presents the context, scope and modalities of the expertise study, presents the main artificial and natural sources of radiofrequency radiation, gives a detailed presentation of new exposure sources (new signals, new radio-electric networks and their applications like mobile phones, pads, mobile television, local wireless networks, RFID, so on). It describes metrology and dose measurement techniques for electromagnetic fields (exposure characterization in laboratory, characterization of the electromagnetic environment, individual exposure measurement devices, digital dosimetry). It addresses the efficiency of anti-wave devices. The next part presents the literature survey (method, analysis, results). The authors then report an assessment of the risk level related to radio-frequencies for the central nervous system (neurotoxicity mechanisms, cognitive functions, memory and behaviour, sleep and circadian rhythms, hearing functions, neurological and neuro-degenerative diseases), and an assessment of the risk level of radio-frequencies for other non-carcinogenic effects (possible mechanisms, reproduction, immunology, endocrine system, and so on). They discuss the researches on potential carcinogenic mechanisms. They give an overview of the evolutions of regulations and management measures in France, and propose a set of recommendations

  2. A sheath model for arbitrary radiofrequency waveforms

    Science.gov (United States)

    Turner, M. M.; Chabert, Pascal

    2012-10-01

    The sheath is often the most important region of a rf plasma, because discharge impedance, power absorption and ion acceleration are critically affected by the behaviour of the sheath. Consequently, models of the sheath are central to any understanding of the physics of rf plasmas. Lieberman has supplied an analytical model for a radio-frequency sheath driven by a single frequency, but in recent years interest has been increasing in radio-frequency discharges excited by increasingly complex wave forms. There has been limited success in generalizing the Lieberman model in this direction, because of mathematical complexities. So there is essentially no sheath model available to describe many modern experiments. In this paper we present a new analytical sheath model, based on a simpler mathematical framework than that of Lieberman. For the single frequency case, this model yields scaling laws that are identical in form to those of Lieberman, differing only by numerical coefficients close to one. However, the new model may be straightforwardly solved for arbitrary current waveforms, and may be used to derive scaling laws for such complex waveforms. In this paper, we will describe the model and present some illustrative examples.

  3. Explanation for Cancer in Rats, Mice and Humans due to Cell Phone Radiofrequency Radiation

    OpenAIRE

    Feldman, Bernard J.

    2016-01-01

    Very recently, the National Toxicology Program reported a correlation between exposure to whole body 900 MHz radiofrequency radiation and cancer in the brains and hearts of Sprague Dawley male rats. This paper proposes the following explanation for these results. The neurons around the rat's brain and heart form closed electrical circuits and, following Faraday's Law, 900 MHz radiofrequency radiation induces 900 MHz electrical currents in these neural circuits. In turn, these 900 MHz currents...

  4. Optical Measurements of Strong Radio-Frequency Fields Using Rydberg Atoms

    Science.gov (United States)

    Miller, Stephanie Anne

    There has recently been an initiative toward establishing atomic measurement standards for field quantities, including radio-frequency, millimeter-wave, and micro-wave electric fields. Current measurement standards are obtained using dipole antennas, which are fundamentally limited in frequency bandwidth (set by the physical size of the antenna) and accuracy (due to the metal perturbing the field during the measurement). Establishing an atomic standard rectifies these problems. My thesis work contributes to an ongoing effort towards establishing the viability of using Rydberg electromagnetically induced transparency (EIT) to perform atom-based measurements of radio-frequency (RF) fields over a wide range of frequencies and field strengths, focusing on strong-field measurements. Rydberg atoms are atoms with an electron excited to a high principal quantum number, resulting in a high sensitivity to an applied field. A model based on Floquet theory is implemented to accurately describe the observed atomic energy level shifts from which information about the field is extracted. Additionally, the effects due to the different electric field domains within the measurement volume are accurately modeled. Absolute atomic measurements of fields up to 296 V/m within a +/-0.35% relative uncertainty are demonstrated. This is the strongest field measured at the time of data publication. Moreover, the uncertainty is over an order of magnitude better than that of current standards. A vacuum chamber setup that I implemented during my graduate studies is presented and its unique components are detailed. In this chamber, cold-atom samples are generated and Rydberg atoms are optically excited within the ground-state sample. The Rydberg ion detection and imaging procedure are discussed, particularly the high magnification that the system provides. By analyzing the position of the ions, the spatial correlation g(2) (r) of Rydberg-atom distributions can be extracted. Aside from ion

  5. Percutaneous osteoid osteoma treatment with combination of radiofrequency and alcohol ablation

    Energy Technology Data Exchange (ETDEWEB)

    Akhlaghpoor, S. [Noor Medical Imaging Center, Tehran (Iran, Islamic Republic of)]. E-mail: akhlaghpoor@nmri-ir.com; Tomasian, A. [Noor Medical Imaging Center, Tehran (Iran, Islamic Republic of); Arjmand Shabestari, A. [Noor Medical Imaging Center, Tehran (Iran, Islamic Republic of); Ebrahimi, M. [Noor Medical Imaging Center, Tehran (Iran, Islamic Republic of); Alinaghizadeh, M.R. [Noor Medical Imaging Center, Tehran (Iran, Islamic Republic of)

    2007-03-15

    Aim: To assess the efficacy of percutaneous osteoid osteoma treatment using a combination of radiofrequency ablation (RFA) and alcohol ablation with regard to technical and long-term clinical success. Materials and methods: From December 2001 to November 2004, RFA and subsequent alcohol ablation was performed on 54 patients with osteoid osteoma, diagnosed clinically using radiography, computed tomography (CT) and symptoms. Under general anaesthesia, treatment was performed via percutaneous access under thin section (2 mm) spiral CT guidance in all cases with an 11 G radiofrequency-compatible coaxial needle and 2 mm coaxial drill system and 1.0 cm active tip 17 G non-cooled radiofrequency needle. RFA was performed at 90 {sup o}C for a period of 6 min. After needle removal, 0.5-1.0 ml absolute alcohol (99.8% concentration) was injected directly into the nidus using a 20 G needle. Patients were discharged within 24 h and followed up clinically (at 1 week, 1 month and every 3 months thereafter). Results: The technical success rate was 100%. Complications occurred in two patients consisting of local mild cellulitis in entry site and peripheral small zone paresthesia on the anterior part of leg. The follow-up period range was 13-48 months (mean {+-} SD, 28.2 {+-} 7.4 months). Prompt pain relief and return to normal activities were observed in 52 of 54 patients. Recurrent pain occurred in two patients after a 1 and 3 months period of being pain free, respectively; a second RFA and alcohol ablation was performed achieving successful results. Primary and secondary clinical success rates were 96.3% (52/54 patients) and 100% (2/2 patients), respectively. Conclusion: Percutaneous osteoid osteoma treatment with combination of radiofrequency and alcohol ablation is safe, effective and minimally invasive with high primary and secondary success rates. Persistent or recurrent lesions can be effectively re-treated.

  6. Percutaneous osteoid osteoma treatment with combination of radiofrequency and alcohol ablation

    International Nuclear Information System (INIS)

    Akhlaghpoor, S.; Tomasian, A.; Arjmand Shabestari, A.; Ebrahimi, M.; Alinaghizadeh, M.R.

    2007-01-01

    Aim: To assess the efficacy of percutaneous osteoid osteoma treatment using a combination of radiofrequency ablation (RFA) and alcohol ablation with regard to technical and long-term clinical success. Materials and methods: From December 2001 to November 2004, RFA and subsequent alcohol ablation was performed on 54 patients with osteoid osteoma, diagnosed clinically using radiography, computed tomography (CT) and symptoms. Under general anaesthesia, treatment was performed via percutaneous access under thin section (2 mm) spiral CT guidance in all cases with an 11 G radiofrequency-compatible coaxial needle and 2 mm coaxial drill system and 1.0 cm active tip 17 G non-cooled radiofrequency needle. RFA was performed at 90 o C for a period of 6 min. After needle removal, 0.5-1.0 ml absolute alcohol (99.8% concentration) was injected directly into the nidus using a 20 G needle. Patients were discharged within 24 h and followed up clinically (at 1 week, 1 month and every 3 months thereafter). Results: The technical success rate was 100%. Complications occurred in two patients consisting of local mild cellulitis in entry site and peripheral small zone paresthesia on the anterior part of leg. The follow-up period range was 13-48 months (mean ± SD, 28.2 ± 7.4 months). Prompt pain relief and return to normal activities were observed in 52 of 54 patients. Recurrent pain occurred in two patients after a 1 and 3 months period of being pain free, respectively; a second RFA and alcohol ablation was performed achieving successful results. Primary and secondary clinical success rates were 96.3% (52/54 patients) and 100% (2/2 patients), respectively. Conclusion: Percutaneous osteoid osteoma treatment with combination of radiofrequency and alcohol ablation is safe, effective and minimally invasive with high primary and secondary success rates. Persistent or recurrent lesions can be effectively re-treated

  7. Issues in epidemiological studies of radiofrequency workers

    International Nuclear Information System (INIS)

    Hocking, B.

    1985-01-01

    The paper reviews some of the issues in a proposed epidemiological study of radiofrequency workers. First a few other epidemiological studies are discussed to illustrate some of the common problems such as inadequate definition of effects and/or exposure. Then technical problems in determining dosage and responses as well as study design are reviewed, and finally the administrative aspects of ethics, industrial relations and costs are considered

  8. ROLE OF RADIOFREQUENCY ABLATION IN ADENOMA SEBACEUM

    Directory of Open Access Journals (Sweden)

    Ch. Madh

    2016-03-01

    Full Text Available Adenoma sebaceum, pathognomonic of tuberous sclerosis, are tiny angiofibromas which commonly occur over central part of face. Recurrence after treatment is common and hence a need for inexpensive, safe and efficient treatment is required. Radiofrequency ablation is a safe and an economical procedure and has been known to cause less scarring with good aesthetic results compared to other ablative methods such as electrocautery.

  9. Radiofrequency sensory ablation as a treatment for symptomatic unilateral lumbosacral junction pseudarticulation (Bertolotti's syndrome): a case report.

    Science.gov (United States)

    Burnham, Robert

    2010-06-01

    Describe the clinical presentation, diagnostic evaluation, and successful treatment of a case of symptomatic unilateral lumbosacral junction pseudarticulation using a novel radiofrequency nerve ablation technique. A 56-year-old female patient who had suffered with low back and right upper buttock pain for 16 years experienced incomplete relief with L4/5 facet joint radiofrequency ablation. She was found to have an elongated right L5 transverse process that articulated with the sacral ala (Bertolotti's syndrome). Fluoroscopically guided local anesthetic/corticosteroid injection into the pseudarthrosis eliminated her residual right buttock pain for the duration of the local anesthetic only. Complete pain relief was achieved by injecting local anesthetic circumferentially around the posterior pseudarthrosis articular margin. Accordingly, bipolar radiofrequency strip thermal lesions were created at the same locations. Complete pain relief and full restoration of function was achieved for 16 months postprocedure. This case report describes a novel radiofrequency technique for treating symptomatic lumbosacral junction pseudarticulation that warrants further evaluation.

  10. Comparison of Voice Quality Between Patients Who Underwent Inferior Turbinoplasty or Radiofrequency Cauterization.

    Science.gov (United States)

    Göker, Ayşe Enise; Aydoğdu, İmran; Saltürk, Ziya; Berkiten, Güler; Atar, Yavuz; Kumral, Tolgar Lütfi; Uyar, Yavuz

    2017-01-01

    The aim of this study was to analyze and compare the vocal quality in patients who underwent either submucosal turbinectomy or radiofrequency cauterization. In this study, we enrolled 60 patients diagnosed with inferior concha hypertrophy. These patients were divided into two groups by using computer program "Research Randomizer." Of the 60 patients, 30 underwent submucosal inferior turbinoplasty and 30 underwent radiofrequency cauterization. The control group was composed of 30 healthy adults with no nasal or upper aerodigestive system pathology. The patients were checked at weeks 1, 2, and 4. Voice records were taken before the procedure and at week 4 postprocedure. The mean age of patients in the inferior turbinoplasty group was 29.4 years (range: 19-42 years); in the radiofrequency group, it was 30.30 years (range: 18-50 years). There was no statistical difference in age between groups. In the inferior turbinoplasty group, there were 16 male and 14 female patients, and in the radiofrequency group, there were 13 male and 17 female patients. There was no significant difference in the number of males and females between groups. Voice professionals, especially singers, actors, and actresses, should be informed about possible voice changes before undergoing endonasal surgery because these individuals are more sensitive to changes in resonance organs. We believe that voice quality should be regarded as a highly important parameter when measuring the success of endonasal surgery. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  11. Investigation of beech wood modified by radio-frequency discharge plasma

    Czech Academy of Sciences Publication Activity Database

    Novák, I.; Popelka, A.; Špitalský, Z.; Mičušík, M.; Omastová, M.; Valentin, M.; Sedliačik, J.; Janigová, I.; Kleinová, A.; Šlouf, Miroslav

    2015-01-01

    Roč. 119, September (2015), s. 88-94 ISSN 0042-207X Institutional support: RVO:61389013 Keywords : radio-frequency plasma * beech wood * adhesive properties Subject RIV: CD - Macromolecular Chemistry Impact factor: 1.558, year: 2015

  12. Radiofrequency neurolysis in a clinical model. Neuropathological correlation

    International Nuclear Information System (INIS)

    Smith, H.P.; McWhorter, J.M.; Challa, V.R.

    1981-01-01

    Reports differ on which nerve fibers are affected by radiofrequency lesions made in peripheral nerves, some stating that primarily the myelinated delta and unmyelinated C fibers are destroyed, others stating that the destruction affects all sizes of nerve fibers and both myelinated and unmyelinated fibers. This study was designed to confirm one of those two findings, and to study the role that different temperatures might play in determining which fibers are affected. Radiofrequency lesions (85 degrees C for 2 minutes) were made in dogs by placing a temperature-monitored electrode into the lumber intervertebral foramina. The dogs were killed at intervals up to 6 weeks after rhizotomy, and the lesions were studied by light and electron microscopy. In all lesions, there was a total loss of unmyelinated fibers and a nearly total loss of myelinated fibers. In other dogs, 2-minute lesions were made at 45 degrees, 55 degrees, 65 degrees, and 75 degrees C, and the lesions examined 1 week later. Again, all sizes and all types of fibers were destroyed

  13. Evaluation of three sample preparation methods for the direct identification of bacteria in positive blood cultures by MALDI-TOF.

    Science.gov (United States)

    Tanner, Hannah; Evans, Jason T; Gossain, Savita; Hussain, Abid

    2017-01-18

    Patient mortality is significantly reduced by rapid identification of bacteria from sterile sites. MALDI-TOF can identify bacteria directly from positive blood cultures and multiple sample preparation methods are available. We evaluated three sample preparation methods and two MALDI-TOF score cut-off values. Positive blood culture bottles with organisms present in Gram stains were prospectively analysed by MALDI-TOF. Three lysis reagents (Saponin, SDS, and SepsiTyper lysis bufer) were applied to each positive culture followed by centrifugation, washing and protein extraction steps. Methods were compared using the McNemar test and 16S rDNA sequencing was used to assess discordant results. In 144 monomicrobial cultures, using ≥2.000 as the cut-off value, species level identifications were obtained from 69/144 (48%) samples using Saponin, 86/144 (60%) using SDS, and 91/144 (63%) using SepsiTyper. The difference between SDS and SepsiTyper was not statistically significant (P = 0.228). Differences between Saponin and the other two reagents were significant (P direct MALDI-TOF identification were observed in monomicrobial cultures. In 32 polymicrobial cultures, MALDI-TOF identified one organism in 34-75% of samples depending on the method. This study demonstrates two inexpensive in-house detergent lysis methods are non-inferior to a commercial kit for analysis of positive blood cultures by direct MALDI-TOF in a clinical diagnostic microbiology laboratory.

  14. Pulsed radiofrequency microwave fields around a quadrupole particle accelerator: measurement and safety evaluation

    International Nuclear Information System (INIS)

    Sachdev, R.N.; Swarup, G.; Rajan, K.K.; Joseph, L.

    1996-01-01

    Pulsed radiofrequency microwave radiation (RFMR) fields occur during the use of high power microwaves in plasma heating in fusion research, plasma and solid state diagnostics, particle accelerators and colliders, pump sources in lasers, material processing as well as in high power radars. This paper describes the experimental work done at Trombay for measurement of pulsed RFMR fields in the working area of a radiofrequency quadrupole (RFQ) accelerator with the use of a meter calibrated in continuous field and interprets the observed fields in the light of existing protection criteria for pulsed RFMR fields. (author)

  15. Identification and estimation of nonlinear models using two samples with nonclassical measurement errors

    KAUST Repository

    Carroll, Raymond J.

    2010-05-01

    This paper considers identification and estimation of a general nonlinear Errors-in-Variables (EIV) model using two samples. Both samples consist of a dependent variable, some error-free covariates, and an error-prone covariate, for which the measurement error has unknown distribution and could be arbitrarily correlated with the latent true values; and neither sample contains an accurate measurement of the corresponding true variable. We assume that the regression model of interest - the conditional distribution of the dependent variable given the latent true covariate and the error-free covariates - is the same in both samples, but the distributions of the latent true covariates vary with observed error-free discrete covariates. We first show that the general latent nonlinear model is nonparametrically identified using the two samples when both could have nonclassical errors, without either instrumental variables or independence between the two samples. When the two samples are independent and the nonlinear regression model is parameterized, we propose sieve Quasi Maximum Likelihood Estimation (Q-MLE) for the parameter of interest, and establish its root-n consistency and asymptotic normality under possible misspecification, and its semiparametric efficiency under correct specification, with easily estimated standard errors. A Monte Carlo simulation and a data application are presented to show the power of the approach.

  16. Painless, safe, and efficacious noninvasive skin tightening, body contouring, and cellulite reduction using multisource 3DEEP radiofrequency.

    Science.gov (United States)

    Harth, Yoram

    2015-03-01

    In the last decade, Radiofrequency (RF) energy has proven to be safe and highly efficacious for face and neck skin tightening, body contouring, and cellulite reduction. In contrast to first-generation Monopolar/Bipolar and "X -Polar" RF systems which use one RF generator connected to one or more skin electrodes, multisource radiofrequency devices use six independent RF generators allowing efficient dermal heating to 52-55°C, with no pain or risk of other side effects. In this review, the basic science and clinical results of body contouring and cellulite treatment using multisource radiofrequency system (Endymed PRO, Endymed, Cesarea, Israel) will be discussed and analyzed. © 2015 Wiley Periodicals, Inc.

  17. Theoretical resolving power of a radiofrequency mass spectrometer

    International Nuclear Information System (INIS)

    Coc, A.; Le Gac, R.; Saint Simon, M. de; Thibault, C.; Touchard, F.

    1988-01-01

    Radiofrequency mass spectrometers of L.G. Smith's type can reach a resolving power of 10 6 -10 7 and a precision of 10 -9 -10 -10 . The resolving power, shape of peaks and limitations are described. As an example, the spectrometer to be used in an experiment aimed at measuring the anti p/p mass ratio is considered. (orig.)

  18. Interaction of cold radiofrequency plasma with seeds of beans (Phaseolus vulgaris)

    Science.gov (United States)

    Bormashenko, Edward; Shapira, Yekaterina; Grynyov, Roman; Whyman, Gene; Bormashenko, Yelena; Drori, Elyashiv

    2015-01-01

    The impact of cold radiofrequency air plasma on the wetting properties and water imbibition of beans (Phaseolus vulgaris) was studied. The influence of plasma on wetting of a cotyledon and seed coat (testa) was elucidated. It was established that cold plasma treatment leads to hydrophilization of the cotyledon and tissues constituting the testa when they are separately exposed to plasma. By contrast, when the entire bean is exposed to plasma treatment, only the external surface of the bean is hydrophilized by the cold plasma. Water imbibition by plasma-treated beans was studied. Plasma treatment markedly accelerates the water absorption. The crucial role of a micropyle in the process of water imbibition was established. It was established that the final percentage of germination was almost the same in the cases of plasma-treated, untreated, and vacuum-pumped samples. However, the speed of germination was markedly higher for the plasma-treated samples. The influence of the vacuum pumping involved in the cold plasma treatment on the germination was also clarified. PMID:25948708

  19. Radio-frequency transparent demodulation for broadband hybrid wireless-optical links

    DEFF Research Database (Denmark)

    Zibar, Darko; Sambaraju, Rakesh; Alemany, Ruben

    2010-01-01

    A novel demodulation technique which is transparent to radio-frequency (RF) carrier frequency is presented and experimentally demonstrated for multigigabit wireless signals. The presented demodulation technique employs optical single-sideband filtering, coherent detection, and baseband digital si...

  20. In vivo imaging of a stable paramagnetic probe by pulsed-radiofrequency electron paramagnetic resonance spectroscopy

    DEFF Research Database (Denmark)

    Murugesan; Cook; Devasahayam

    1997-01-01

    , Recent advances in radiofrequency (RF) electronics have enabled the generation of pulses of the order of 10-50 ns. Such short pulses provide adequate spectral coverage for EPR studies at 300 MHz resonant frequency. Acquisition of free induction decays (FID) of paramagnetic species possessing...... inhomogeneously broadened narrow lines after pulsed excitation is feasible with an appropriate digitizer/averager. This report describes the use of time-domain RF EPR spectrometry and imaging for in vivo applications. FID responses were collected from a water-soluble, narrow line width spin probe within phantom...... samples in solution and also when infused intravenously in an anesthetized mouse. Using static magnetic field gradients and back-projection methods of image reconstruction, two-dimensional images of the spin-probe distribution were obtained in phantom samples as well as in a mouse. The resolution...

  1. Radiofrequency electromagnetic fields in the Cookridge area of Leeds

    CERN Document Server

    Fuller, K; Judd, P M; Lowe, A J; Shaw, J

    2002-01-01

    On the 8 and 9 May 2002 representatives of the National Radiological Protection Board (NRPB) performed a radiofrequency electromagnetic field survey in the Cookridge area of Leeds in order to assess exposure to radio signals from transmitters mounted on a water tower/a lattice tower and a radio station tower. Guidelines on limiting exposure to radio signals have been published by NRPB and the International Commission on Non-Ionizing Radiation Protection (ICNIRP). These guidelines are designed to prevent established adverse effects on human health. During this survey, the total exposures due to all radio signals from 30 MHz to 18000 MHz (18 GHz) were measured. This frequency range was chosen as it includes mobile phone base station transmissions, which are at around 900 and 1800 MHz and super high frequency (SHF) transmissions from most of the large microwave dish antennas mounted on the towers. In addition, other major sources of radiofrequency electromagnetic fields in the environment such as broadcast radio...

  2. Cell oxidation-reduction imbalance after modulated radiofrequency radiation.

    Science.gov (United States)

    Marjanovic, Ana Marija; Pavicic, Ivan; Trosic, Ivancica

    2015-01-01

    Aim of this study was to evaluate an influence of modulated radiofrequency field (RF) of 1800 MHz, strength of 30 V/m on oxidation-reduction processes within the cell. The assigned RF field was generated within Gigahertz Transversal Electromagnetic Mode cell equipped by signal generator, modulator, and amplifier. Cell line V79, was irradiated for 10, 30, and 60 min, specific absorption rate was calculated to be 1.6 W/kg. Cell metabolic activity and viability was determined by MTT assay. In order to define total protein content, colorimetric method was used. Concentration of oxidised proteins was evaluated by enzyme-linked immunosorbent assay. Reactive oxygen species (ROS) marked with fluorescent probe 2',7'-dichlorofluorescin diacetate were measured by means of plate reader device. In comparison with control cell samples, metabolic activity and total protein content in exposed cells did not differ significantly. Concentrations of carbonyl derivates, a product of protein oxidation, insignificantly but continuously increase with duration of exposure. In exposed samples, ROS level significantly (p < 0.05) increased after 10 min of exposure. Decrease in ROS level was observed after 30-min treatment indicating antioxidant defence mechanism activation. In conclusion, under the given laboratory conditions, modulated RF radiation might cause impairment in cell oxidation-reduction equilibrium within the growing cells.

  3. Sphenopalatine ganglion treatment with radiofrequency in a Sluder syndrome young patient

    Directory of Open Access Journals (Sweden)

    Carmelo Costa

    2014-12-01

    Full Text Available Sluder's neuralgia or sphenopalatine ganglion neuralgia is a pain syndrome first described by Sluder in 1908. The clinical picture is characterised by pain starting around the eye and the route of nose. Typically the pain is accompanied by parasympathetic disautonomic signs such as lacrimation and/or rhinorrhea. However, many official headache classifications do not mention the Sluder's neuralgia at all, which is instead classified as a cluster headache (CH. In case of resistance to pharmacological management pain the physician could recur to sphenopalatine ganglion (GSP neurolytic block with continuous radiofrequency (CRF or its no ablative alternative with pulsed radiofrequency (PRF. We are presenting a case of a 16-year-old woman who suffered from a typical Sluder's neuralgia successfully treated with GSP PRF.

  4. Influence of transcatheter hepatic artery embolization using iodized oil on radiofrequency ablation of hepatic neoplasms

    International Nuclear Information System (INIS)

    Du Xilin; Ma Qingjiu; Wang Yiqing; Wang Zhimin; Zhang Hongxin

    2004-01-01

    Objective: To observe the effect of iodized oil on radiofrequency thermal ablation (RFA) of hepatic neoplasms by using a cluster array of ten separate electrodes. Methods: The patients were divided into 2 groups, group A with transcatheter hepatic artery embolization, group B without transcatheter hepatic artery embolization. All patients were undergone radiofrequency ablation of hepatic neoplasms. Results: The time of RFA for group A was (9 ± 2.1) minutes, showing the diameter of necrosis of (5.3 ± 1.4) cm. The time of RFA for group B was (16 ± 4. 6) minutes demonstrating the diameter of necrosis of (3.5 ± 1.8) cm (P<0.01). Conclusions: These findings suggest that radiofrequency thermal ablation of hepatic neoplasms with transcatheter hepatic artery embolization using iodized oil might improve the safety and synergic effect

  5. Radiofrequency attenuator and method

    Science.gov (United States)

    Warner, Benjamin P [Los Alamos, NM; McCleskey, T Mark [Los Alamos, NM; Burrell, Anthony K [Los Alamos, NM; Agrawal, Anoop [Tucson, AZ; Hall, Simon B [Palmerston North, NZ

    2009-01-20

    Radiofrequency attenuator and method. The attenuator includes a pair of transparent windows. A chamber between the windows is filled with molten salt. Preferred molten salts include quarternary ammonium cations and fluorine-containing anions such as tetrafluoroborate (BF.sub.4.sup.-), hexafluorophosphate (PF.sub.6.sup.-), hexafluoroarsenate (AsF.sub.6.sup.-), trifluoromethylsulfonate (CF.sub.3SO.sub.3.sup.-), bis(trifluoromethylsulfonyl)imide ((CF.sub.3SO.sub.2).sub.2N.sup.-), bis(perfluoroethylsulfonyl)imide ((CF.sub.3CF.sub.2SO.sub.2).sub.2N.sup.-) and tris(trifluoromethylsulfonyl)methide ((CF.sub.3SO.sub.2).sub.3C.sup.-). Radicals or radical cations may be added to or electrochemically generated in the molten salt to enhance the RF attenuation.

  6. Radiofrequency spark chambers and delay line resonators

    International Nuclear Information System (INIS)

    Sayag, Jacques

    1971-01-01

    According to a suggestion of A. Kastler, a spark chamber was excited by an undamped radiofrequency pulse and tracks about 1 mm wide obtained; the result was interpreted by computation of the coefficients of electronic amplification and partial ambipolar diffusion. This work led us to the construction of a new fast triggering undamped wave-train generator of very high tension (patent taken out by the C.E.A. under the no.: EN 7 134 650 the 27.9.1971). Since this apparatus uses a resonant storage line, its design implied a precise knowledge of high impedance delay lines. The experimental radiofrequency spectra of the input impedance of opened or short-circuited lines were plotted completely and analysed by the circuits theory, new measuring methods were established, dispersion relations accurately checked and the equivalence of the formulas, within the third order, with theses of Debye's Dipolar Absorption demonstrated. General properties of Hilbert's transform were also investigated. From the experimental point of view, the electromagnetic energy storage process was extended to the case of a liquid nitrogen-immersed resonant delay line. The good behavior of the cryogenic experiment, where the main difficulty of icing was overcame by the construction of special electrodes, offers great promise for extrapolation to superconductivity. (author) [fr

  7. Capacitively coupled radio-frequency discharges in nitrogen at low pressures

    KAUST Repository

    Alves, Luí s Lemos; Marques, Luí s S A; Pintassilgo, Carlos D.; Wattieaux, Gaë tan; Es-sebbar, Et-touhami; Berndt, Johannes; Kovačević, Eva; Carrasco, Nathalie; Boufendi, Laï fa; Cernogora, Guy

    2012-01-01

    This paper uses experiments and modelling to study capacitively coupled radio-frequency (rf) discharges in pure nitrogen, at 13.56MHz frequency, 0.11 mbar pressures and 230W coupled powers. Experiments performed on two similar (not twin) setups

  8. Radiofrequency fields in MAS solid state NMR probes

    Science.gov (United States)

    Tošner, Zdeněk; Purea, Armin; Struppe, Jochem O.; Wegner, Sebastian; Engelke, Frank; Glaser, Steffen J.; Reif, Bernd

    2017-11-01

    We present a detailed analysis of the radiofrequency (RF) field over full volume of a rotor that is generated in a solenoid coil. On top of the usually considered static distribution of amplitudes along the coil axis we describe dynamic radial RF inhomogeneities induced by sample rotation. During magic angle spinning (MAS), the mechanical rotation of the sample about the magic angle, a spin packet travels through areas of different RF fields and experiences periodical modulations of both the RF amplitude and the phase. These modulations become particularly severe at the end regions of the coil where the relative RF amplitude varies up to ±25% and the RF phase changes within ±30°. Using extensive numerical simulations we demonstrate effects of RF inhomogeneity on pulse calibration and for the ramped CP experiment performed at a wide range of MAS rates. In addition, we review various methods to map RF fields using a B0 gradient along the sample (rotor axis) for imaging purposes. Under such a gradient, a nutation experiment provides directly the RF amplitude distribution, a cross polarization experiment images the correlation of the RF fields on the two channels according to the Hartmann-Hahn matching condition, while a spin-lock experiment allows to calibrate the RF amplitude employing the rotary resonance recoupling condition. Knowledge of the RF field distribution in a coil provides key to understand its effects on performance of a pulse sequence at the spectrometer and enables to set robustness requirements in the experimental design.

  9. First experience using navigation-guided radiofrequency kyphoplasty for sacroplasty in sacral insufficiency fractures

    Energy Technology Data Exchange (ETDEWEB)

    Klingler, J.H.; Kluge, P.; Sircar, R.; Kogias, E.; Scholz, C.; Krueger, M.T.; Scheiwe, C.; Hubbe, U. [Freiburg Univ. Medical Center, Freiburg (Germany). Dept. of Neurosurgery

    2013-08-15

    Purpose: To evaluate the efficacy and safety of navigation-guided radiofrequency kyphoplasty for sacroplasty in patients with sacral insufficiency fractures. Methods: In this single-center retrospective observational study, four consecutive patients with sacral insufficiency fractures were treated with navigation-guided radiofrequency kyphoplasty for sacroplasty between April 2010 and May 2012. Symptom characteristics, pain duration and pain intensity were recorded for each patient. Cement extravasation was evaluated in thin-sliced and triplanar reconstructed CT scans of the sacrum. Results: Four female patients with painful sacral insufficiency fractures and extensive osteopenic areas significantly improved from an average pre-treatment VAS score of 8.3 {+-} 0.5 to 2.3 {+-} 1.0 (p < 0.001) on the first postoperative day and to 1.3 {+-} 1.9 (p < 0.004) at follow-up (mean, 20.1 weeks). Slight cement extravasations were observed without evidence of being symptomatic. No major complications or procedure-related morbidity were noted. Conclusion: From the limited experience in four patients, navigation-guided radiofrequency kyphoplasty appears to be a safe and effective treatment option for sacral insufficiency fractures even though asymptomatic cement extravasation was noted. The use of navigation based on intraoperative 3 D images simplifies the positioning of the navigated bone needles via the long axis approach. The radiofrequency kyphoplasty system provides the possibility to administer a sufficient amount of bone cement with a well-defined viscosity over the entire period of the procedure leading to high security and low cement extravasation. Sacroplasty provides rapid and enduring pain relief and facilitates prompt mobilization. (orig.)

  10. A new catheter design for combined radiofrequency ablation and optoacoustic treatment monitoring using copper-coated light-guides

    Science.gov (United States)

    Rebling, Johannes; Oyaga Landa, Francisco Javier; Deán-Ben, Xosé Luis; Razansky, Daniel

    2018-02-01

    Electrosurgery, i.e. the application of radiofrequency current for tissue ablation, is a frequently used treatment for many cardiac arrhythmias. Electrophysiological and anatomic mapping, as well as careful radiofrequency power control typically guide the radiofrequency ablation procedure. Despite its widespread application, accurate monitoring of the lesion formation with sufficient spatio-temporal resolution remains challenging with the existing imaging techniques. We present a novel integrated catheter for simultaneous radiofrequency ablation and optoacoustic monitoring of the lesion formation in real time and 3D. The design combines the delivery of both electric current and optoacoustic excitation beam in a single catheter consisting of copper-coated multimode light-guides and its manufacturing is described in detail. The electrical current causes coagulation and desiccation while the excitation light is locally absorbed, generating OA responses from the entire treated volume. The combined ablation-monitoring capabilities were verified using ex-vivo bovine tissue. The formed ablation lesions showed a homogenous coagulation while the ablation was monitored in realtime with a volumetric frame rate of 10 Hz over 150 seconds.

  11. Effect of cell-phone radiofrequency on angiogenesis and cell invasion in human head and neck cancer cells.

    Science.gov (United States)

    Alahmad, Yaman M; Aljaber, Mohammed; Saleh, Alaaeldin I; Yalcin, Huseyin C; Aboulkassim, Tahar; Yasmeen, Amber; Batist, Gerald; Moustafa, Ala-Eddin Al

    2018-05-13

    Today, the cell phone is the most widespread technology globally. However, the outcome of cell-phone radiofrequency on head and neck cancer progression has not yet been explored. The chorioallantoic membrane (CAM) and human head and neck cancer cell lines, FaDu and SCC25, were used to explore the outcome of cell-phone radiofrequency on angiogenesis, cell invasion, and colony formation of head and neck cancer cells, respectively. Western blot analysis was used to investigate the impact of the cell phone on the regulation of E-cadherin and Erk1/Erk2 genes. Our data revealed that cell-phone radiofrequency promotes angiogenesis of the CAM. In addition, the cell phone enhances cell invasion and colony formation of human head and neck cancer cells; this is accompanied by a downregulation of E-cadherin expression. More significantly, we found that the cell phone can activate Erk1/Erk2 in our experimental models. Our investigation reveals that cell-phone radiofrequency could enhance head and neck cancer by stimulating angiogenesis and cell invasion via Erk1/Erk2 activation. © 2018 Wiley Periodicals, Inc.

  12. Split-face histological and biochemical evaluation of tightening efficacy using temperature- and impedance-controlled continuous non-invasive radiofrequency energy.

    Science.gov (United States)

    Boisnic, Sylvie; Divaris, Marc; Branchet, Marie-Christine; Nelson, Andrew A

    2017-06-01

    Bipolar radiofrequency (RF) is capable of heating dermal collagen fibers and inducing skin tightening by collagen remodeling. To substantiate safety and improvement of skin laxity following skin heating with a novel temperature- and impedance-controlled non-invasive radiofrequency (RF) device by histological and biochemical evaluations. A split-face study was performed on 4 subjects who underwent 8 weekly RF sessions on one side of their face, leaving the other side an untreated control and then underwent facelift procedure. Clinical evaluation by photographs was done prior to the surgical procedure. Ex vivo fragments were harvested from both sides and compared. Morphometric analysis of dermal collagen fibers, collagen synthesis, and elastin synthesis evaluations were compared in triplicates. Facial skin tightening was apparent in split-face photographs. A significant increase of 7.9% in dermal collagen content, and a significant increase of 34.7% in collagen synthesis were demonstrated in the treated samples. No statistically significant effect on elastin synthesis was detected. Skin tightening following treatment with non-invasive RF has proven histologically and biochemically to derive from increase in dermal collagen synthesis and content.

  13. Simple Sample Preparation Method for Direct Microbial Identification and Susceptibility Testing From Positive Blood Cultures.

    Science.gov (United States)

    Pan, Hong-Wei; Li, Wei; Li, Rong-Guo; Li, Yong; Zhang, Yi; Sun, En-Hua

    2018-01-01

    Rapid identification and determination of the antibiotic susceptibility profiles of the infectious agents in patients with bloodstream infections are critical steps in choosing an effective targeted antibiotic for treatment. However, there has been minimal effort focused on developing combined methods for the simultaneous direct identification and antibiotic susceptibility determination of bacteria in positive blood cultures. In this study, we constructed a lysis-centrifugation-wash procedure to prepare a bacterial pellet from positive blood cultures, which can be used directly for identification by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF MS) and antibiotic susceptibility testing by the Vitek 2 system. The method was evaluated using a total of 129 clinical bacteria-positive blood cultures. The whole sample preparation process could be completed in identification was 96.49% for gram-negative bacteria and 97.22% for gram-positive bacteria. Vitek 2 antimicrobial susceptibility testing of gram-negative bacteria showed an agreement rate of antimicrobial categories of 96.89% with a minor error, major error, and very major error rate of 2.63, 0.24, and 0.24%, respectively. Category agreement of antimicrobials against gram-positive bacteria was 92.81%, with a minor error, major error, and very major error rate of 4.51, 1.22, and 1.46%, respectively. These results indicated that our direct antibiotic susceptibility analysis method worked well compared to the conventional culture-dependent laboratory method. Overall, this fast, easy, and accurate method can facilitate the direct identification and antibiotic susceptibility testing of bacteria in positive blood cultures.

  14. Radiofrequency Wire Recanalization of Chronically Thrombosed TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Majdalany, Bill S., E-mail: bmajdala@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States); Elliott, Eric D., E-mail: eric.elliott@osumc.edu [The Ohio State University Wexner Medical Center, Division of Interventional Radiology, Department of Radiology (United States); Michaels, Anthony J., E-mail: Anthony.michaels@osumc.edu; Hanje, A. James, E-mail: James.Hanje@osumc.edu [The Ohio State University Wexner Medical Center, Division of Gastroenterology and Hepatology, Department of Medicine (United States); Saad, Wael E. A., E-mail: wsaad@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States)

    2016-07-15

    Radiofrequency (RF) guide wires have been applied to cardiac interventions, recanalization of central venous thromboses, and to cross biliary occlusions. Herein, the use of a RF wire technique to revise chronically occluded transjugular intrahepatic portosystemic shunts (TIPS) is described. In both cases, conventional TIPS revision techniques failed to revise the chronically thrombosed TIPS. RF wire recanalization was successfully performed through each of the chronically thrombosed TIPS, demonstrating initial safety and feasibility in this application.

  15. Cluster chemical ionization for improved confidence level in sample identification by gas chromatography/mass spectrometry.

    Science.gov (United States)

    Fialkov, Alexander B; Amirav, Aviv

    2003-01-01

    Upon the supersonic expansion of helium mixed with vapor from an organic solvent (e.g. methanol), various clusters of the solvent with the sample molecules can be formed. As a result of 70 eV electron ionization of these clusters, cluster chemical ionization (cluster CI) mass spectra are obtained. These spectra are characterized by the combination of EI mass spectra of vibrationally cold molecules in the supersonic molecular beam (cold EI) with CI-like appearance of abundant protonated molecules, together with satellite peaks corresponding to protonated or non-protonated clusters of sample compounds with 1-3 solvent molecules. Like CI, cluster CI preferably occurs for polar compounds with high proton affinity. However, in contrast to conventional CI, for non-polar compounds or those with reduced proton affinity the cluster CI mass spectrum converges to that of cold EI. The appearance of a protonated molecule and its solvent cluster peaks, plus the lack of protonation and cluster satellites for prominent EI fragments, enable the unambiguous identification of the molecular ion. In turn, the insertion of the proper molecular ion into the NIST library search of the cold EI mass spectra eliminates those candidates with incorrect molecular mass and thus significantly increases the confidence level in sample identification. Furthermore, molecular mass identification is of prime importance for the analysis of unknown compounds that are absent in the library. Examples are given with emphasis on the cluster CI analysis of carbamate pesticides, high explosives and unknown samples, to demonstrate the usefulness of Supersonic GC/MS (GC/MS with supersonic molecular beam) in the analysis of these thermally labile compounds. Cluster CI is shown to be a practical ionization method, due to its ease-of-use and fast instrumental conversion between EI and cluster CI, which involves the opening of only one valve located at the make-up gas path. The ease-of-use of cluster CI is analogous

  16. Papillary thyroid carcinoma treated with radiofrequency ablation in a patient with hypertrophic cardiomyopathy: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Jian Yi; Liu, Xiao Sun; Zhang, Qing; Hong, Yan Yun; Song, Bin; Teng, Xiao Dong; Yu, Ji Ren [The First Affiliated Hospital, Medical College, Zhejiang University, Hangzhou (China)

    2016-07-15

    Standard therapy has not been established for thyroid cancer when a thyroidectomy is contraindicated due to systemic disease. Herein, we reported a patient who had hypertrophic cardiomyopathy and papillary thyroid carcinoma treated by radiofrequency ablation because of inability to tolerate a thyroidectomy. Radiofrequency ablation can be used to treat thyroid cancer when surgery is not feasible, although the long-term outcome needs further observation.

  17. Papillary Thyroid Carcinoma Treated with Radiofrequency Ablation in a Patient with Hypertrophic Cardiomyopathy: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Jianyi; Liu, Xiaosun; Zhang, Qing; Hong, Yanyun; Song, Bin [Department of Gastrointestinal and Thyroid Surgery, The First Affiliated Hospital, Medical College, Zhejiang University, Hangzhou 310003 (China); Teng, Xiaodong [Department of Pathology, The First Affiliated Hospital, Medical College, Zhejiang University, Hangzhou 310003 (China); Yu, Jiren [Department of Gastrointestinal and Thyroid Surgery, The First Affiliated Hospital, Medical College, Zhejiang University, Hangzhou 310003 (China)

    2016-11-01

    Standard therapy has not been established for thyroid cancer when a thyroidectomy is contraindicated due to systemic disease. Herein, we reported a patient who had hypertrophic cardiomyopathy and papillary thyroid carcinoma treated by radiofrequency ablation because of inability to tolerate a thyroidectomy. Radiofrequency ablation can be used to treat thyroid cancer when surgery is not feasible, although the long-term outcome needs further observation.

  18. Experimental and clinical studies with radiofrequency-induced thermal endometrial ablation for functional menorrhagia

    Energy Technology Data Exchange (ETDEWEB)

    Phipps, J.H.; Lewis, B.V.; Prior, M.V.; Roberts, T. (Watford General Hospital, Herts (England))

    1990-11-01

    A method of ablating the endometrium has been introduced into clinical practice that uses radiofrequency electromagnetic energy to heat the endometrium, using a probe inserted through the cervix. Preliminary studies suggest that over 80% of patients treated will develop either amenorrhea or a significant reduction in flow. The advantages of radiofrequency endometrial ablation over laser ablation or resection are the avoidance of intravascular fluid absorption, simplicity (no special operative hysteroscopic skills are required), speed of operation, and reduced cost compared with the Nd:YAG laser. In this paper, we describe the experimental studies performed during development of this new technique.

  19. Tunable radio-frequency photonic filter based on an actively mode-locked fiber laser.

    Science.gov (United States)

    Ortigosa-Blanch, A; Mora, J; Capmany, J; Ortega, B; Pastor, D

    2006-03-15

    We propose the use of an actively mode-locked fiber laser as a multitap optical source for a microwave photonic filter. The fiber laser provides multiple optical taps with an optical frequency separation equal to the external driving radio-frequency signal of the laser that governs its repetition rate. All the optical taps show equal polarization and an overall Gaussian apodization, which reduces the sidelobes. We demonstrate continuous tunability of the filter by changing the external driving radio-frequency signal of the laser, which shows good fine tunability in the operating range of the laser from 5 to 10 GHz.

  20. Thermistor guided radiofrequency ablation of atrial insertion sites in patients with accessory pathways.

    Science.gov (United States)

    Tracy, C M; Moore, H J; Solomon, A J; Rodak, D J; Fletcher, R D

    1995-11-01

    Radiofrequency ablation has gained acceptance in the treatment of patients with symptomatic Wolff-Parkinson-White syndrome. The purpose of this study was to characterize the relation between temperature and other electroconductive parameters in patients undergoing atrial insertion accessory pathway ablation utilizing a thermistor equipped catheter. The mean temperature and power at sites of atrial insertion ablation are lower than has been previously associated with creation of radiofrequency lesions in the ventricle. While high cavitary blood flow in the atrium may result in cooling, the thinner atrial tissue may require less energy to achieve adequate heating than ventricular myocardium.

  1. Outcomes of Radiofrequency Ablation for Dysplastic Barrett's Esophagus: A Comprehensive Review

    Science.gov (United States)

    Iabichino, Giuseppe; Arena, Monica; Consolo, Pierluigi; Morace, Carmela; Opocher, Enrico; Mangiavillano, Benedetto

    2016-01-01

    Barrett's esophagus is a condition in which the normal squamous lining of the esophagus has been replaced by columnar epithelium containing intestinal metaplasia induced by recurrent mucosal injury related to gastroesophageal reflux disease. Barrett's esophagus is a premalignant condition that can progress through a dysplasia-carcinoma sequence to esophageal adenocarcinoma. Multiple endoscopic ablative techniques have been developed with the goal of eradicating Barrett's esophagus and preventing neoplastic progression to esophageal adenocarcinoma. For patients with high-grade dysplasia or intramucosal neoplasia, radiofrequency ablation with or without endoscopic resection for visible lesions is currently the most effective and safe treatment available. Recent data demonstrate that, in patients with Barrett's esophagus and low-grade dysplasia confirmed by a second pathologist, ablative therapy results in a statistically significant reduction in progression to high-grade dysplasia and esophageal adenocarcinoma. Treatment of dysplastic Barrett's esophagus with radiofrequency ablation results in complete eradication of both dysplasia and of intestinal metaplasia in a high proportion of patients with a low incidence of adverse events. A high proportion of treated patients maintain the neosquamous epithelium after successful treatment without recurrence of intestinal metaplasia. Following successful endoscopic treatment, endoscopic surveillance should be continued to detect any recurrent intestinal metaplasia and/or dysplasia. This paper reviews all relevant publications on the endoscopic management of Barrett's esophagus using radiofrequency ablation. PMID:28070182

  2. Automated Estimation of Melanocytic Skin Tumor Thickness by Ultrasonic Radiofrequency Data.

    Science.gov (United States)

    Andrekute, Kristina; Valiukeviciene, Skaidra; Raisutis, Renaldas; Linkeviciute, Gintare; Makstiene, Jurgita; Kliunkiene, Renata

    2016-05-01

    High-frequency (>20-MHz) ultrasound (US) is a noninvasive preoperative tool for assessment of melanocytic skin tumor thickness. Ultrasonic melanocytic skin tumor thickness estimation is not always easy and is related to the experience of the clinician. In this article, we present an automated thickness measurement method based on time-frequency analysis of US radiofrequency signals. The study was performed on 52 thin (≤1-mm) melanocytic skin tumors (46 melanocytic nevi and 6 melanomas). Radiofrequency signals were obtained with a single-element focused transducer (fundamental frequency, 22 MHz; bandwidth, 12-28 MHz). The radiofrequency data were analyzed in the time-frequency domain to make the tumor boundaries more noticeable. The thicknesses of the tumors were evaluated by 3 different metrics: histologically measured Breslow thickness, manually measured US thickness, and automatically measured US thickness. The results showed a higher correlation coefficient between the automatically measured US thickness and Breslow thickness (r= 0.83; Pmeasured US thickness (r = 0.68; P measurement algorithm was 96.55%, and the specificity was 78.26% compared with histologic measurement. The sensitivity of the manually measured US thickness was 75.86%, and the specificity was 73.91%. The efficient automated tumor thickness measurement method developed could be used as a tool for preoperative assessment of melanocytic skin tumor thickness. © 2016 by the American Institute of Ultrasound in Medicine.

  3. Identification of uranium signatures in swipe samples on verification of nuclear activities for nuclear safeguards purposes

    International Nuclear Information System (INIS)

    Pestana, Rafael Cardoso Baptistini

    2013-01-01

    The use of environmental sampling for safeguards purposes, has been applied by the International Atomic Energy Agency–IAEA since 1996 and are routinely used as a complementary measure to strengthen the traditional nuclear safeguards procedures. The aim is verify if the states signatory to the safeguards agreements are not diverging their peaceful nuclear activities for undeclared nuclear activities. This work describes a new protocol of collect and analysis of the swipe samples for identification of nuclear signatures that may be related to the nuclear activities developed in the inspected facility. This work was used as a case of study a real uranium conversion plant of the nuclear fuel cycle of IPEN. The strategy proposed uses different analytical techniques, such as alpha radiation meter, SEM-EDX and ICP-MS to identify signatures of uranium adhered to the swipe samples. In the swipe samples analysis, it was possible to identify particles of UO 2 F 2 and UF4 through the morphological comparison and semi-quantitative analyses performed by SEM-EDX technique. In this work, methods were used that as a result has the average isotopic composition of the sample, in which the enrichment ranged from 1.453 ± 0.023 to 18.24 % ± 0.15 % in the 235 U isotope. Through these externally collections, a non-intrusive sampling, it was possible to identify enriched material handling activities with enrichment of 1.453 % ± 0.023 % to 6.331 ± 0.055 % in the isotope 235 U, as well as the use of reprocessed material, through the identification of the 236 U isotope. The uncertainties obtained for the n( 235 U)/n( 238 U) ratio varied from 0.40% to 0.86 % for the internal swipe samples. (author)

  4. Comparison of GSM Modulated and CW Radiofrequency Radiation on Cells

    International Nuclear Information System (INIS)

    Pavicic, I.; Marjanovic, A.M.; Trosic, I.

    2011-01-01

    The aim of our study was to evaluate and compare effect of global system of mobile (GSM) modulation and continuous wave (CW) radiofrequency radiation (RF) on proliferation ability and viability of V79 Chinese hamster lung cells. Previously prepared samples of cells in culture were exposed for 1, 2 and 3 hours both to 915 MHz GSM modulated and to 935 MHz CW RF field in gigahertz transversal electromagnetic mode cell (GTEM-cell). Electric field strength for cells exposed to GSM modulation was set at 10 V/m and for CW exposed cells was 8.2 V/m. Average specific absorption rate (SAR) was calculated to be for GSM 0.23 W/kg and for CW 0.12 W/kg. V79 samples were plated in concentration of 1x10 4 cells/mL. Cell proliferation was determined by cell counts for each hour of exposure during five post-exposure days. Trypan blue exclusion test was used to determine cell viability. In comparison to control cell samples, proliferation of GSM irradiated cells showed significant decrease after 3 hours of exposure on the second and third post-exposure day. CW exposed cell samples showed significant decrease after 3 hours of exposure on the third post-exposure day. Viability of GSM and CW exposed cells did not significantly differ from matched control cell samples. Both applied RF fields have shown similar effect on cell culture growth, and cell viability of V79 cell line. In addition, applied GSM modulated RF radiation demonstrate bigger influence on proliferation of cells. (author)

  5. Effect of percutaneous renal sympathetic nerve radiofrequency ablation in patients with severe heart failure.

    Science.gov (United States)

    Dai, Qiming; Lu, Jing; Wang, Benwen; Ma, Genshan

    2015-01-01

    This study aimed to investigate the clinical feasibility and effects of percutaneous renal sympathetic nerve radiofrequency ablation in patients with heart failure. A total of 20 patients with heart failure were enrolled, aged from 47 to 75 years (63±10 years). They were divided into the standard therapy (n = 10), and renal nerve radiofrequency ablation groups (n = 10). There were 15 males and 5 female patients, including 8 ischemic cardiomyopathy, 8 dilated cardiomyopathy, and 8 hypertensive cardiopathy. All of the patients met the criteria of New York Heart Association classes III-IV cardiac function. Patients with diabetes and renal failure were excluded. Percutaneous renal sympathetic nerve radiofrequency ablation was performed on the renal artery wall under X-ray guidance. Serum electrolytes, neurohormones, and 24 h urine volume were recorded 24 h before and after the operation. Echocardiograms were performed to obtain left ventricular ejection fraction at baseline and 6 months. Heart rate, blood pressure, symptoms of dyspnea and edema were also monitored. After renal nerve ablation, 24 h urine volume was increased, while neurohormone levels were decreased compared with those of pre-operation and standard therapy. No obvious change in heart rate or blood pressure was recorded. Symptoms of heart failure were improved in patients after the operation. No complications were recorded in the study. Percutaneous renal sympathetic nerve radiofrequency ablation may be a feasible, safe, and effective treatment for the patients with severe congestive heart failure.

  6. Radiofrequency Ablation versus Cryoablation in the Treatment of Paroxysmal Atrial Fibrillation: A Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Ali H. Hachem

    2018-01-01

    Full Text Available Background. Pulmonary vein isolation is commonly performed using radiofrequency energy with cryoablation gaining acceptance. We performed a meta-analysis of randomized controlled trials which compared radiofrequency versus cryoablation for patients with atrial fibrillation. Methods. A systematic search strategy identified both published and unpublished articles from inception to November 10, 2016, in multiple databases. The primary outcomes for this meta-analysis were long-term freedom from atrial fibrillation at 12-month follow-up and overall postoperative complication rates. For all included studies, the methodological quality was assessed through the Cochrane Collaboration’s tool for risk of bias. Results. A total of 247 articles were identified with eight being included in this review as they satisfied the prespecified inclusion criteria. Overall, there was no significant difference in freedom from atrial fibrillation at ≥12-month follow-up between those receiving cryoballoon and radiofrequency ablation, respectively (OR = 0.98, CI = 0.67–1.43, I2 = 56%, p=0.90. Additionally, the secondary outcomes of duration of ablation, fluoroscopy time, and ablation time failed to reach significance. Cryoballoon ablation had significantly greater odds of postoperative phrenic nerve injury at 12-month follow-up. Conclusions. Our meta-analysis suggests that cryoballoon ablation provides comparable benefits with regard to freedom from atrial fibrillation at medium-term follow-up, fluoroscopy time, ablation time, operative duration, and overall complication rate in comparison to radiofrequency ablation.

  7. Optimization of Sample Preparation for the Identification and Quantification of Saxitoxin in Proficiency Test Mussel Sample using Liquid Chromatography-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Kirsi Harju

    2015-11-01

    Full Text Available Saxitoxin (STX and some selected paralytic shellfish poisoning (PSP analogues in mussel samples were identified and quantified with liquid chromatography-tandem mass spectrometry (LC-MS/MS. Sample extraction and purification methods of mussel sample were optimized for LC-MS/MS analysis. The developed method was applied to the analysis of the homogenized mussel samples in the proficiency test (PT within the EQuATox project (Establishment of Quality Assurance for the Detection of Biological Toxins of Potential Bioterrorism Risk. Ten laboratories from eight countries participated in the STX PT. Identification of PSP toxins in naturally contaminated mussel samples was performed by comparison of product ion spectra and retention times with those of reference standards. The quantitative results were obtained with LC-MS/MS by spiking reference standards in toxic mussel extracts. The results were within the z-score of ±1 when compared to the results measured with the official AOAC (Association of Official Analytical Chemists method 2005.06, pre-column oxidation high-performance liquid chromatography with fluorescence detection (HPLC-FLD.

  8. Radiofrequency catheter ablation for electrical storm in a patient with dilated cardiomyopathy.

    Science.gov (United States)

    Kolettis, Theofilos M; Naka, Katerina K; Katsouras, Christos S

    2005-01-01

    We report a case of successful radiofrequency catheter ablation in a patient with dilated cardiomyopathy, who presented with multiple, haemodynamically poorly tolerated episodes of monomorphic ventricular tachycardia, resistant to antiarrhythmic drug treatment. The ablation procedure consisted of focal ablation of three mapped left ventricular sites, using pace and activation mapping. Additional linear ablation lesions were created across these sites. After the procedure, the patient remained free of tachycardia episodes and seven days post-ablation he underwent implantation of a cardioverter-defibrillator. During a twelve-month follow-up period, the patient has remained free of monomorphic ventricular tachycardia episodes. Radiofrequency catheter ablation is feasible in electrical storm, using conventional mapping techniques, even in haemodynamically unstable tachycardias.

  9. Effect of power modulation on properties of pulsed capacitively coupled radiofrequency discharges

    International Nuclear Information System (INIS)

    Samara, V; Bowden, M D; Braithwaite, N St J

    2010-01-01

    We describe measurements of plasma properties of pulsed, low pressure, capacitively coupled discharges operated in argon. The study aims to determine the effect of modulating the radiofrequency power during the discharge part of the pulse cycle. Measurements of local electron density and optical emission were made in capacitively coupled rf discharges generated in a Gaseous Electronics Conference (GEC) reference reactor. Gas pressure was in the range 7-70 Pa, rf power in the range 1-100 W and pulse durations in the range 10 μs-100 ms. The results indicate that the ignition and afterglow decay processes in pulsed discharges can be controlled by modulating the shape of applied radiofrequency pulse.

  10. Spectroscopic photoacoustic imaging of radiofrequency ablation in the left atrium

    NARCIS (Netherlands)

    S. Iskander-Rizk (Sophinese); P. Kruizinga (Pieter); A.F.W. van der Steen (Ton); G. van Soest (Gijs)

    2018-01-01

    textabstractCatheter-based radiofrequency ablation for atrial fibrillation has long-term success in 60-70% of cases. A better assessment of lesion quality, depth, and continuity could improve the procedure’s outcome. We investigate here photoacoustic contrast between ablated and healthy atrial-wall

  11. Klebsiella pneumonia, a Microorganism that Approves the Non-linear Responses to Antibiotics and Window Theory after Exposure to Wi-Fi 2.4 GHz Electromagnetic Radiofrequency Radiation

    Directory of Open Access Journals (Sweden)

    Taheri M.

    2015-09-01

    Full Text Available Background: Drug resistance is widely believed to be an increasingly serious threat to global public health. We have previously reported that short term exposure of microorganisms to diagnostic ultrasound waves could significantly alter their sensitivity to antibiotics. In our previous studies, Klebsiella pneumoniae showed major differences in the sensitivity to antibiotics in exposed and non-exposed samples. This study was aimed at investigating the alteration of antibiotic resistance of Klebsiella pneumonia, after exposure to Wi-Fi 2.4 GHz electromagnetic radiofrequency radiation. Materials and Methods: In this in vitro study, three replicate agar plates were used for each test. The antibiotic susceptibility test was carried out using disc diffusion method on Mueller Hinton agar plates and the inhibition zones in both control and exposed groups were measured. A common Wi-Fi router was used in this study as the radiofrequency exposure source. Irradiated samples were exposed to Wi-Fi radiofrequency radiation for 3, 4.5 and 8 hours. Results: Statistically significant variations of sensitivity to antibiotics were found for all studied antibiotics after 4.5 hours of RF exposure, compared to non-exposed bacteria. Interestingly, the mean diameters of the inhibition zones after 3 hours of exposure were less than those exposed for 4.5 hours. Following this rise in the sensitivity to antibiotics, a fall was observed in the bacteria exposed for 8 hours for all studied antibiotics. Conclusion: The findings of this study show a statistically significant rise in the sensitivity of Klebsiella pneumoniae to different antibiotics after 4.5 hours of exposure to 2.4 GHz Wi-Fi radiation, followed by a fall after 8 hours of exposure. These observations can be interpreted by the concept of non-linearity in the responses of Klebsiella pneumoniae to different antibiotics after exposure to electromagnetic radiofrequency radiation. As in this study a minimum level of

  12. Clinical application of radiofrequency ablation combined with bronchial artery infusion of docetaxel in treating non-small cell lung cancer

    International Nuclear Information System (INIS)

    Lu Xiong; Chen Fang; Lin Yun; Tan Taikang; Wei Wei

    2010-01-01

    Objective: To discuss the clinical application of radiofrequency ablation combined with bronchial artery infusion of docetaxel in treating non-small cell lung cancer and to summarize the experience of using this therapy in clinical practice. Methods: Radiofrequency ablation was performed in twenty-one patients with lung cancer. The diagnosis was confirmed by CT-guided percutaneous needle biopsy or bronchoscopic biopsy in all patients. One week after radiofrequency ablation treatment, bronchial artery infusion of docetaxel was conducted. The therapeutic results were observed and evaluated. Results: After the treatment, the lesion's size was markedly reduced and the clinical symptoms were dramatically improved in all patients. Conclusion: Radiofrequency ablation combined with bronchial artery infusion of docetaxel is a safe, effective and simple technique with excellent therapeutic results for the treatment of non-small cell lung cancer. It is really worth popularizing this technique in clinical practice. (authors)

  13. Occupational exposure of NRM spectrometrists to static and radiofrequency fields

    International Nuclear Information System (INIS)

    Berlana, Tania; Ubeda, Alejandro

    2017-01-01

    Occupational exposure to static and radiofrequency fields emitted by nuclear magnetic resonance spectrometers was assessed through systematic field metering during operation of 19 devices in nine research centers. Whereas no measurable levels of radiofrequency radiation were registered outside the spectrometers, significant exposure to static field was detected, with maximum values recorded at the user s hand (B = 683.00 mT) and head thorax (B = 135.70 mT) during spectrometer manipulation. All values were well below the exposure limits set by the European standard for workers protection against the effects of acute field exposure only. As for potential effects of chronic exposure, waiting for more complete knowledge, adoption of technical and operational strategies for exposure minimizing is advisable. In this respect, the data revealed that compared with standard magnetic shielding, ultra-shield technology allows a 20-65-fold reduction of the field strength received by the operator. (authors)

  14. Ion source with radiofrequency mass filter for sputtering purposes

    International Nuclear Information System (INIS)

    Sielanko, J.; Sowa, M.

    1990-01-01

    The Kaufman ion source with radiofrequency mass filter is described. The construction as well as operating characteristics of ion source are presented. The arrangement is suitable for range distribution measurements of implanted layers, where the sputtering rate has to be constant over the wide range of sputtering time. 4 figs., 17 refs. (author)

  15. Identification of hydrologic and geochemical pathways using high frequency sampling, REE aqueous sampling and soil characterization at Koiliaris Critical Zone Observatory, Crete

    Energy Technology Data Exchange (ETDEWEB)

    Moraetis, Daniel, E-mail: moraetis@mred.tuc.gr [Department of Environmental Engineering, Technical University of Crete, 73100 Chania (Greece); Stamati, Fotini; Kotronakis, Manolis; Fragia, Tasoula; Paranychnianakis, Nikolaos; Nikolaidis, Nikolaos P. [Department of Environmental Engineering, Technical University of Crete, 73100 Chania (Greece)

    2011-06-15

    Highlights: > Identification of hydrological and geochemical pathways within a complex watershed. > Water increased N-NO{sub 3} concentration and E.C. values during flash flood events. > Soil degradation and impact on water infiltration within the Koiliaris watershed. > Analysis of Rare Earth Elements in water bodies for identification of karstic water. - Abstract: Koiliaris River watershed is a Critical Zone Observatory that represents severely degraded soils due to intensive agricultural activities and biophysical factors. It has typical Mediterranean soils under the imminent threat of desertification which is expected to intensify due to projected climate change. High frequency hydro-chemical monitoring with targeted sampling for Rare Earth Elements (REE) analysis of different water bodies and geochemical characterization of soils were used for the identification of hydrologic and geochemical pathways. The high frequency monitoring of water chemical data highlighted the chemical alterations of water in Koiliaris River during flash flood events. Soil physical and chemical characterization surveys were used to identify erodibility patterns within the watershed and the influence of soils on surface and ground water chemistry. The methodology presented can be used to identify the impacts of degraded soils to surface and ground water quality as well as in the design of methods to minimize the impacts of land use practices.

  16. [Clinical study of liver resection with bipolar radiofrequency device: Habib 4X].

    Science.gov (United States)

    Chen, Jian; Dong, Xin; Tang, Zhe; Gao, Shun-liang; Wu, Yu-lian; Fang, He-qing

    2013-08-27

    To assess the application value of a new radiofrequency device Habib 4X in liver resection. A retrospective study was performed during March 2010 to July 2011.Forty-four patients underwent liver resection with radiofrequency device Habib 4X and another 54 patients traditional liver resection.Intraoperative blood loss, blood transfusion, Pringle's maneuver requirement, liver parenchyma transaction time, liver function recovery, complications, mortality and recurrence were recorded. The mean resection time was (67 ± 22) min for Habib 4X group versus (93 ± 23) min for traditional group (P = 0.000). Pringle's maneuver was required in 10 patients (22.7%) for Habib 4X group and 31 (57.4%) for traditional group (P = 0.001). The mean blocking time was (7 ± 2) vs (18 ± 6) min (P = 0.001), mean blood loss volume (243 ± 132) vs (500 ± 421) ml (P = 0.002). Postoperative recovery of liver function was better in Habib 4X group than traditional group. None developed mortality in Habib 4X group. And no resection margin recurred during a 18-month follow-up. Bipolar radiofrequency device Habib 4X is recommended for pre-coagulation in hepatectomy. And the advantages of minimized blood loss and reduced resection time result in its lower rates of morbidity and mortality.

  17. Safety of lumbar spine radiofrequency procedures in the presence of posterior pedicle screws: technical report of a cadaver study.

    Science.gov (United States)

    Gazelka, Halena M; Welch, Tasha L; Nassr, Ahmad; Lamer, Tim J

    2015-05-01

    To determine whether the thermal energy associated with lumbar spine radiofrequency neurotomy (RFN) performed near titanium and stainless steel pedicle screws is conducted to the pedicle screws or adjacent tissues, or both, thus introducing potential for thermal damage to those tissues. Cadaver study. Cadaver laboratory equipped with fluoroscopy, surgical spine implements, and radiofrequency generator. No live human subject; a fresh frozen (and thawed) cadaver torso was used for the study. Titanium and stainless steel pedicle screws were placed in the lumbar spine of a fresh frozen cadaver torso with real-time fluoroscopic guidance. Conventional RFN cannula placement was performed at the level of pedicle screws and a control (nonsurgically altered) lumbar level. Neurotomy was performed with conventional radiofrequency lesioning parameters. Temperatures were recorded at multiple sites through thermistor probes. Direct contact of the radiofrequency cannula with the pedicle screws during conventional RFN produced a substantial increase in temperature in the surrounding soft tissues. A small increase in temperature occurred at the same sites at the control level. Titanium and stainless steel pedicle screws are capable of sustaining large increases in temperature when the radiofrequency probe comes in contact with the screw. These results are suggestive that pedicle screws could serve as a possible source of tissue heating and thermal injury during RFN. Wiley Periodicals, Inc.

  18. Management of pain on hallux valgus with percutaneous intra-articular Pulse-Dose Radiofrequency.

    Science.gov (United States)

    Masala, Salvatore; Fiori, Roberto; Calabria, Eros; Raguso, Mario; de Vivo, Dominique; Cuzzolino, Alessandro; Simonetti, Giovanni

    2017-01-01

    The purpose of our study was to investigate the role of intra-articular pulse-dose radiofrequency in management of painful hallux valgus refractory to conservative therapies. Between November 2010 and April 2012, 51 patients (15 male, 36 female) with a median age of 71.4 years were included in our clinical trial. Under fluoroscopic guidance we introduced a 22 gauge 10 cm length cannula by a percutaneous access in the first metatarsophalangeal joint and its tip was placed intra-articularly. After removing the spindle, a radiofrequency needle with a 5 mm active tip was introduced. The following parameters were used: 1200 pulses at high voltage (45 V) with 20 msec duration followed by 480 msec silent phases. A great reduction in pain intensity was documented at 1 week, 1 month and 3 months after procedures. Pain intensity increased between 5 and 8 months after treatments, so we performed a second procedure in all patients between 7 months and 9 months since the first treatment. Also in this case we obtained a great reduction of pain intensity in the first 3 months after the procedure. Pain intensity returned at preprocedural values after 9 months after second procedure. No complications were observed. Our experience shows pulse-dose radiofrequency is a safe, repeatable and effective technique for managing patients with symptomatic hallux valgus in the short and medium term. Pulse-dose radiofrequency may improve pain control and quality of life in patients with hallux valgus refractory to conservative therapies. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  19. Radiofrequency ablation of atrial tachyarrhythmias in adults with tetralogy of Fallot - predictors of success and outcome.

    Science.gov (United States)

    Ezzat, Vivienne A; Ryan, Matthew J; O'Leary, Justin; Ariti, Cono; Deanfield, John; Pandya, Bejal; Cullen, Shay; Walker, Fiona; Khan, Fakhar; Abrams, Dominic J; Lambiase, Pier D; Lowe, Martin D

    2017-03-01

    Adults with tetralogy of Fallot experience atrial tachyarrhythmias; however, there are a few data on the outcomes of radiofrequency ablation. We examined the characteristics, outcome, and predictors of recurrence of atrial tachyarrhythmias after radiofrequency ablation in tetralogy of Fallot patients. Methods/results Retrospective data were collected from 2004 to 2013. In total, 56 ablations were performed on 37 patients. We identified two matched controls per case: patients with tetralogy of Fallot but no radiofrequency ablation and not known to have atrial tachyarrhythmias. Acute success was 98%. Left atrial arrhythmias increased in frequency over time. The mean follow-up was 41 months; 78% were arrhythmia-free. Number of cardiac surgeries, age, and presence of atrial fibrillation were predictors of recurrence. Lone cavo-tricuspid isthmus-dependent flutter reduced the likelihood of atrial fibrillation. Right and left atria in patients with tetralogy of Fallot were larger in ablated cases than controls. NYHA class was worse in cases and improved after ablation; baseline status predicted death. Of matched non-ablated controls, a number of them had atrial fibrillation. These patients were excluded from the case-control study but analysed separately. Most of them had died during follow-up, whereas of the matched ablated cases all were alive and the majority in sinus rhythm. Patients with tetralogy of Fallot and atrial tachyarrhythmias have more dilated atria than those without atrial tachyarrhythmias. Radiofrequency ablation improves functional status. Left atrial ablation is more commonly required with repeat procedures. There is a high prevalence of atrial tachyarrhythmias, particularly atrial fibrillation, in patients with tetralogy of Fallot; early radiofrequency ablation may have a protective effect against this.

  20. Radionuclide determination in environmental samples by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Lariviere, Dominic; Taylor, Vivien F.; Evans, R. Douglas; Cornett, R. Jack

    2006-01-01

    The determination of naturally occurring and anthropogenic radionuclides in the environment by inductively coupled plasma mass spectrometry has gained recognition over the last fifteen years, relative to radiometric techniques, as the result of improvement in instrumental performance, sample introduction equipment, and sample preparation. With the increase in instrumental sensitivity, it is now possible to measure ultratrace levels (fg range) of many radioisotopes, including those with half-lives between 1 and 1000 years, without requiring very complex sample pre-concentration schemes. However, the identification and quantification of radioisotopes in environmental matrices is still hampered by a variety of analytical issues such as spectral (both atomic and molecular ions) and non-spectral (matrix effect) interferences and instrumental limitations (e.g., abundance sensitivity). The scope of this review is to highlight recent analytical progress and issues associated with the determination of radionuclides by inductively coupled plasma mass spectrometry. The impact of interferences, instrumental limitations (e.g., degree of ionization, abundance sensitivity, detection limits) and low sample-to-plasma transfer efficiency on the measurement of radionuclides by inductively coupled plasma mass spectrometry will be described. Solutions that overcome these issues will be discussed, highlighting their pros and cons and assessing their impact on the measurement of environmental radioactivity. Among the solutions proposed, mass and chemical resolution through the use of sector-field instruments and chemical reactions/collisions in a pressurized cell, respectively, will be described. Other methods, such as unique sample introduction equipment (e.g., laser ablation, electrothermal vaporisation, high efficiency nebulization) and instrumental modifications/optimizations (e.g., instrumental vacuum, radiofrequency power, guard electrode) that improve sensitivity and performance

  1. Simple Sample Preparation Method for Direct Microbial Identification and Susceptibility Testing From Positive Blood Cultures

    Directory of Open Access Journals (Sweden)

    Hong-wei Pan

    2018-03-01

    Full Text Available Rapid identification and determination of the antibiotic susceptibility profiles of the infectious agents in patients with bloodstream infections are critical steps in choosing an effective targeted antibiotic for treatment. However, there has been minimal effort focused on developing combined methods for the simultaneous direct identification and antibiotic susceptibility determination of bacteria in positive blood cultures. In this study, we constructed a lysis-centrifugation-wash procedure to prepare a bacterial pellet from positive blood cultures, which can be used directly for identification by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF MS and antibiotic susceptibility testing by the Vitek 2 system. The method was evaluated using a total of 129 clinical bacteria-positive blood cultures. The whole sample preparation process could be completed in <15 min. The correct rate of direct MALDI-TOF MS identification was 96.49% for gram-negative bacteria and 97.22% for gram-positive bacteria. Vitek 2 antimicrobial susceptibility testing of gram-negative bacteria showed an agreement rate of antimicrobial categories of 96.89% with a minor error, major error, and very major error rate of 2.63, 0.24, and 0.24%, respectively. Category agreement of antimicrobials against gram-positive bacteria was 92.81%, with a minor error, major error, and very major error rate of 4.51, 1.22, and 1.46%, respectively. These results indicated that our direct antibiotic susceptibility analysis method worked well compared to the conventional culture-dependent laboratory method. Overall, this fast, easy, and accurate method can facilitate the direct identification and antibiotic susceptibility testing of bacteria in positive blood cultures.

  2. Effects of Radiofrequency Waves on the Catalase Content in Triticum Aestivum

    International Nuclear Information System (INIS)

    Goiceanu, C.; Artenie, A.; Artenie, V.; Creanga, D.E.

    2001-01-01

    Full text: The aim of the present study is to investigate the possible effects on enzyme biosynthesis in Triticum aestivum cariopsydes due to exposure to traveling radiofrequency (RF) waves. Triticum cariopsydes have been exposed to traveling RF waves inside a transverse electromagnetic (TEM) cell fed by a RF Power Generator. The frequency of the exposure field was 400 MHz. The TEM cell was excited with 2W RF power in order to obtain a power density of about 1 mW/cm2. Four sets of Triticum aestivum samples were placed in four Petri dishes. For each set of Triticum cariopsydes there has been chosen a daily exposure duration of 1, 2, 4 and 8 hours respectively. Experimental exposure was carried out for five consecutive days. After the electromagnetic treatment cariopsydes were let to germinate in Petri dishes on porous filter paper support. A couple of days later the catalase assay was performed. In comparison to the control samples, exposed samples revealed modified catalase content, significantly over the error level (five replays of every sample were assayed in identical experimental conditions in order to provide a reliable statistic result). All exposed samples presented higher catalase levels in comparison to the control samples. However, the experimental data do not suggest an evident analytical dependence between the catalase content and the exposure time duration. We presume that exposure to traveling RF waves seems to be a stimulatory factor of the enzyme biosynthesis being able to improve Triticum capacity of enzyme biosynthesis in the described experimental conditions. (author)

  3. A Stretchable Radio-Frequency Strain Sensor Using Screen Printing Technology.

    Science.gov (United States)

    Jeong, Heijun; Lim, Sungjoon

    2016-11-02

    In this paper, we propose a stretchable radio-frequency (RF) strain sensor fabricated with screen printing technology. The RF sensor is designed using a half-wavelength patch that resonates at 3.7 GHz. The resonant frequency is determined by the length of the patch, and it therefore changes when the patch is stretched. Polydimethylsiloxane (PDMS) is used to create the substrate, because of its stretchable and screen-printable surface. In addition, Dupont PE872 (Dupont, NC, American) silver conductive ink is used to create the stretchable conductive patterns. The sensor performance is demonstrated both with full-wave simulations and with measurements carried out on a fabricated sample. When the length of the patch sensor is increased by a 7.8% stretch, the resonant frequency decreases from 3.7 GHz to 3.43 GHz, evidencing a sensitivity of 3.43 × 10⁷ Hz/%. Stretching the patch along its width does not change the resonant frequency.

  4. Bottom–up protein identifications from microliter quantities of individual human tear samples. Important steps towards clinical relevance.

    Directory of Open Access Journals (Sweden)

    Peter Raus

    2015-12-01

    With 375 confidently identified proteins in the healthy adult tear, the obtained results are comprehensive and in large agreement with previously published observations on pooled samples of multiple patients. We conclude that, to a limited extent, bottom–up tear protein identifications from individual patients may have clinical relevance.

  5. Osteoid Osteoma: Experience with Laser- and Radiofrequency-Induced Ablation

    International Nuclear Information System (INIS)

    Gebauer, Bernhard; Tunn, Per-Ulf; Gaffke, Gunnar; Melcher, Ingo; Felix, Roland; Stroszczynski, Christian

    2006-01-01

    The purpose of this study was to analyze the clinical outcome of osteoid osteoma treated by thermal ablation after drill opening. A total of 17 patients and 20 procedures were included. All patients had typical clinical features (age, pain) and a typical radiograph showing a nidus. In 5 cases, additional histological specimens were acquired. After drill opening of the osteoid osteoma nidus, 12 thermal ablations were induced by laser interstitial thermal therapy (LITT) (9F Power-Laser-Set; Somatex, Germany) and 8 ablations by radiofrequency ablation (RFA) (RITA; StarBurst, USA). Initial clinical success with pain relief has been achieved in all patients after the first ablation. Three patients had an osteoid osteoma recurrence after 3, 9, and 10 months and were successfully re-treated by thermal ablation. No major complication and one minor complication (sensible defect) were recorded. Thermal ablation is a safe and minimally invasive therapy option for osteoid osteoma. Although the groups are too small for a comparative analysis, we determined no difference between laser- and radiofrequency-induced ablation in clinical outcome after ablation

  6. Anatomical characteristics of pulmonary veins for the prediction of postoperative recurrence after radiofrequency catheter ablation of atrial fibrillation.

    Directory of Open Access Journals (Sweden)

    Wei Wei

    Full Text Available BACKGROUND: The relationship between focal pulmonary vein potential and atrial fibrillation (AF has been confirmed. Pulmonary vein (PV isolation and circumferential pulmonary vein ablation have been the most commonly used procedures of radiofrequency ablation. However, few studies have investigated the relationship between anatomical characteristics of PV and AF recurrences after radiofrequency ablation. METHODOLOGY: For 267 AF patients treated by radiofrequency catheter ablation, the anatomic structure characteristics of pulmonary veins were assessed by multi-slice spiral computed tomography while the values of left atrial diameter (LAD were measured with transesophageal ultrasonic cardiogram. After radiofrequency catheter ablation, postoperative recurrence was evaluated during a 10-month term follow-up. PRINCIPAL FINDINGS: During follow-up, postoperative recurrence occurred in 44 patients. The mean diameters of LAD, left superior PV, right superior PV, all left PV, and all superior PV were significantly larger in patients with postoperative recurrence (Recurrence vs. Non-recurrence group; 43.9 ± 6.4 mm vs. 40.7 ± 5.6 mm; 18.4 ± 2.1 mm vs. 17.1 ± 3.1 mm; 18.2 ± 2.8 mm vs. 17.2 mm ± 3.9 mm; 16.4 ± 1.5 mm vs. 15.6 ± 2.5 mm; 18.3 ± 2.1 mm vs. 17.1 ± 3.0 mm; respectively; all P < 0.05. Multivariable survival analysis showed that the type and the course of AF, LAD, and the diameters of all superior PV were the independent risk factors for the postoperative recurrence after radiofrequency catheter ablation. CONCLUSIONS: The enlargements of all superior PV and LAD, long course of diseases, and persistent AF were the independent risk factors for the postoperative recurrence after radiofrequency catheter ablation.

  7. Six years of evidence-based adult dissection tonsillectomy with ultrasonic scalpel, bipolar electrocautery, bipolar radiofrequency or 'cold steel' dissection.

    Science.gov (United States)

    Ragab, S M

    2012-10-01

    To conduct an adequately powered, prospective, randomised, controlled trial comparing adult dissection tonsillectomy using either ultrasonic scalpel, bipolar electrocautery, bipolar radiofrequency or 'cold steel' dissection. Three hundred patients were randomised into four tonsillectomy technique groups. The operative time, intra-operative bleeding, post-operative pain, tonsillar fossa healing, return to full diet, return to work and post-operative complications were recorded. The bipolar radiofrequency group had a shorter mean operative time. The mean intra-operative blood loss during bipolar radiofrequency tonsillectomy was significantly less compared with cold dissection and ultrasonic scalpel tonsillectomy. Pain scores were significantly higher after bipolar electrocautery tonsillectomy. Patients undergoing bipolar electrocautery tonsillectomy required significantly more days to return to full diet and work. The bipolar electrocautery group showed significantly reduced tonsillar fossa healing during the first and second post-operative weeks. In this adult series, bipolar radiofrequency tonsillectomy was superior to ultrasonic, bipolar electrocautery and cold dissection tonsillectomies. This method combines the advantages of 'hot' and 'cold' tonsillectomy.

  8. Black-box modeling to estimate tissue temperature during radiofrequency catheter cardiac ablation: feasibility study on an agar phantom model

    International Nuclear Information System (INIS)

    Blasco-Gimenez, Ramón; Lequerica, Juan L; Herrero, Maria; Hornero, Fernando; Berjano, Enrique J

    2010-01-01

    The aim of this work was to study linear deterministic models to predict tissue temperature during radiofrequency cardiac ablation (RFCA) by measuring magnitudes such as electrode temperature, power and impedance between active and dispersive electrodes. The concept involves autoregressive models with exogenous input (ARX), which is a particular case of the autoregressive moving average model with exogenous input (ARMAX). The values of the mode parameters were determined from a least-squares fit of experimental data. The data were obtained from radiofrequency ablations conducted on agar models with different contact pressure conditions between electrode and agar (0 and 20 g) and different flow rates around the electrode (1, 1.5 and 2 L min −1 ). Half of all the ablations were chosen randomly to be used for identification (i.e. determination of model parameters) and the other half were used for model validation. The results suggest that (1) a linear model can be developed to predict tissue temperature at a depth of 4.5 mm during RF cardiac ablation by using the variables applied power, impedance and electrode temperature; (2) the best model provides a reasonably accurate estimate of tissue temperature with a 60% probability of achieving average errors better than 5 °C; (3) substantial errors (larger than 15 °C) were found only in 6.6% of cases and were associated with abnormal experiments (e.g. those involving the displacement of the ablation electrode) and (4) the impact of measuring impedance on the overall estimate is negligible (around 1 °C)

  9. A Retrospective Evaluation of Subsurface Monopolar Radiofrequency for Lifting of the Face, Neck, and Jawline.

    Science.gov (United States)

    Dendle, Julia; Wu, Douglas C; Fabi, Sabrina G; Melo, Diana; Goldman, Mitchel P

    2016-11-01

    Subsurface monopolar radiofrequency (SMRF) has emerged as a new method for reducing skin laxity via the controlled delivery of thermal energy below the skin using a radiofrequency probe. To evaluate the overall efficacy of the treatment and satisfaction ratings of subjects who underwent a single SMRF treatment to the face, neck, or jawline (or some combination). A retrospective, single-center study was conducted in which data were obtained via subject follow-ups at 90 and 180 days posttreatment. A total of 35 subjects, 6 men and 29 women, underwent a single SMRF treatment. Overall, 77% of subjects reported improvement, and 64% reported satisfaction with the treatment site at Day 180 posttreatment. Subsurface monopolar radiofrequency represents an effective modality to achieve skin tightening of the face, neck, and jawline. The data suggest that there is an energy delivery threshold, above which a higher percentage of subjects report satisfaction. Analysis of treatments parameters suggests an optimal treatment time and tissue temperature that should be achieved to maximize results.

  10. The relative importance of perceptual and memory sampling processes in determining the time course of absolute identification.

    Science.gov (United States)

    Guest, Duncan; Kent, Christopher; Adelman, James S

    2018-04-01

    In absolute identification, the extended generalized context model (EGCM; Kent & Lamberts, 2005, 2016) proposes that perceptual processing determines systematic response time (RT) variability; all other models of RT emphasize response selection processes. In the EGCM-RT the bow effect in RTs (longer responses for stimuli in the middle of the range) occurs because these middle stimuli are less isolated, and as perceptual information is accumulated, the evidence supporting a correct response grows more slowly than for stimuli at the ends of the range. More perceptual information is therefore accumulated in order to increase certainty in response for middle stimuli, lengthening RT. According to the model reducing perceptual sampling time should reduce the size of the bow effect in RT. We tested this hypothesis in 2 pitch identification experiments. Experiment 1 found no effect of stimulus duration on the size of the RT bow. Experiment 2 used multiple short stimulus durations as well as manipulating set size and stimulus spacing. Contrary to EGCM-RT predictions, the bow effect on RTs was large for even very short durations. A new version of the EGCM-RT could only capture this, alongside the effect of stimulus duration on accuracy, by including both a perceptual and a memory sampling process. A modified version of the selective attention, mapping, and ballistic accumulator model (Brown, Marley, Donkin, & Heathcote, 2008) could also capture the data, by assuming psychophysical noise diminishes with increased exposure duration. This modeling suggests systematic variability in RT in absolute identification is largely determined by memory sampling and response selection processes. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  11. Influence of the radio-frequency power on the physical and optical properties of plasma polymerized cyclohexane thin films

    Energy Technology Data Exchange (ETDEWEB)

    Manaa, C., E-mail: chadlia.el.manaa@gmail.com [Laboratoire de Physique de la Matière Condensée, Université de Picardie Jules Verne, UFR des Sciences d' Amiens, 33 rue Saint Leu, 80039 Amiens CEDEX 2 (France); Laboratoire des Matériaux Avancés et Phénomènes Quantiques, Université de Tunis El-Manar, Faculté des Sciences de Tunis, Campus universitaire El-Manar, 1068 Tunis (Tunisia); Lejeune, M. [Laboratoire de Physique de la Matière Condensée, Université de Picardie Jules Verne, UFR des Sciences d' Amiens, 33 rue Saint Leu, 80039 Amiens CEDEX 2 (France); Kouki, F. [Laboratoire des Matériaux Avancés et Phénomènes Quantiques, Université de Tunis El-Manar, Faculté des Sciences de Tunis, Campus universitaire El-Manar, 1068 Tunis (Tunisia); Durand-Drouhin, O. [Laboratoire de Physique de la Matière Condensée, Université de Picardie Jules Verne, UFR des Sciences d' Amiens, 33 rue Saint Leu, 80039 Amiens CEDEX 2 (France); Bouchriha, H. [Laboratoire des Matériaux Avancés et Phénomènes Quantiques, Université de Tunis El-Manar, Faculté des Sciences de Tunis, Campus universitaire El-Manar, 1068 Tunis (Tunisia); and others

    2014-06-02

    We investigate in the present study the effects of the radio-frequency plasma power on the opto-electronical properties of the polymeric amorphous hydrogenated carbon thin films deposited at room temperature and different radio-frequency powers by plasma-enhanced chemical vapor deposition method using cyclohexane as precursor. A combination of U.V.–Visible and infrared transmission measurements is applied to characterize the bonding and electronic properties of these films. Some film properties namely surface roughness, contact angle, surface energy, and optical properties are found to be significantly influenced by the radio-frequency power. The changes in these properties are analyzed within the microstructural modifications occurring during growth. - Highlights: • Effects of the radio-frequency power on the optoelectronic properties of thin films • Elaboration of plasma polymerized thin films using cyclohexane as precursor gas • The use of U.V.–Visible-infrared transmission, and optical gap • Study of the surface topography of the films by using Atomic Force microscopy • The use of a capacitively coupled plasma enhanced chemical vapor deposition method.

  12. Influence of the radio-frequency power on the physical and optical properties of plasma polymerized cyclohexane thin films

    International Nuclear Information System (INIS)

    Manaa, C.; Lejeune, M.; Kouki, F.; Durand-Drouhin, O.; Bouchriha, H.

    2014-01-01

    We investigate in the present study the effects of the radio-frequency plasma power on the opto-electronical properties of the polymeric amorphous hydrogenated carbon thin films deposited at room temperature and different radio-frequency powers by plasma-enhanced chemical vapor deposition method using cyclohexane as precursor. A combination of U.V.–Visible and infrared transmission measurements is applied to characterize the bonding and electronic properties of these films. Some film properties namely surface roughness, contact angle, surface energy, and optical properties are found to be significantly influenced by the radio-frequency power. The changes in these properties are analyzed within the microstructural modifications occurring during growth. - Highlights: • Effects of the radio-frequency power on the optoelectronic properties of thin films • Elaboration of plasma polymerized thin films using cyclohexane as precursor gas • The use of U.V.–Visible-infrared transmission, and optical gap • Study of the surface topography of the films by using Atomic Force microscopy • The use of a capacitively coupled plasma enhanced chemical vapor deposition method

  13. The efficacy of two electrodes radiofrequency technique: comparison study using a cadaveric interspinous ligament and temperature measurement using egg white.

    Science.gov (United States)

    Lee, Chang-Hyung; Derby, Richard; Choi, Hyun-Seok; Lee, Sang-Heon; Kim, Se Hoon; Kang, Yoon Kyu

    2010-01-01

    One technique in radiofrequency neurotomies uses 2 electrodes that are simultaneously placed to lie parallel to one another. Comparing lesions on cadaveric interspinous ligament tissue and measuring the temperature change in egg white allows us to accurately measure quantitatively the area of the lesion. Fresh cadaver spinal tissue and egg white tissue were used. A series of samples were prepared with the electrodes placed 1 to 7 mm apart. Using radiofrequency, the needle electrodes were heated in sequential or simultaneous order and the distance of the escaped lesion area and temperature were measured. Samples of cadaver interspinous ligament showed sequential heating of the needles limits the placement of the needle electrodes up to 2 mm apart from each other and up to 4 mm apart when heated simultaneously. The temperature at the escaped lesion area decreased according to the distance for egg white. There was a significant difference in temperature at the escaped lesion area up to 6 mm apart and the temperature was above 50 degrees celsius up to 5 mm in simultaneous lesion and 3 mm in the sequential lesion. The limitations of this study include cadaveric experimentation and use of intraspinous ligament rather than medial branch of the dorsal ramus which is difficult to identify. Heating the 2 electrodes simultaneously appears to coagulate a wider area and potentially produce better results in less time.

  14. The identification of type 1 Gaucher disease patients, asymptomatic cases and carriers in The Netherlands using urine samples: an evaluation

    NARCIS (Netherlands)

    Aerts, J. M.; Sa Miranda, M. C.; Wanzeller de Lacerda, L.; van Weely, S.; Donker-Koopman, W.; Brouwer-Kelder, B.; Jansen, D. C.; van Leeuwen, M.; Schram, A. W.; Tsiapara, A.

    1991-01-01

    The feasibility of using urine samples for the identification of patients with Gaucher disease and carriers has been investigated. It was found that the pH of a urine sample should be pH 6.0 or lower to ensure stability of lysosomal hydrolases. Two parameters of glucocerebrosidase, which is

  15. Radiofrequency therapy in back pain and complex regional pain syndrome (CRPS

    Directory of Open Access Journals (Sweden)

    Norina Bergamin

    2011-01-01

    Full Text Available Percutaneous radiofrequency procedures are frequently used in the management of chronic pain. Continuous radiofrequency (CRF has been established as a safe and effective treatment for pain originating from facet and sacroiliac joints by way of co-agulation of their nerve supply. Different methods have been proposed to account for the complex nerve supply of the sacroiliac joint. Due to its neurodestructive property, CRF was limited to the treatment of neuropathic pain. When applied to the dorsal root ganglion (DRG for spinal pain or to the sympathetic ganglia in treatment of CRPS, heat related side effects have been reported. With the development of pulsed radiofrequency (PRF, a less destructive alternative to CRF became available, that is more suitable to treat neuropathic pain. PRF was adopted in the treatment of several pain conditions with different success. The results with PRF adjacent to the DRG are promising, whereas for facet and sacroiliac joint pain PRF could not yet be proven equally effective as CRF. As for PRF in CRPS there is almost no evidence available. The potential of PRF seems to lie in those areas where CRF is of limited value. Con-versely, it is questionable if PRF will ever be equally effective in indications, where CRF is already well established. Despite its active use in clinical practice, PRF is not validated yet nor is its mode of action. The literature in both cases is accumulating but further studies are urgently needed.

  16. Plasma heating by radiofrequency in the electron cyclotron resonance (ECR)

    International Nuclear Information System (INIS)

    Cunha Raposo, C. da; Aihara, S.; Universidade Estadual de Campinas

    1982-01-01

    The characteristics of the experimental set-up mounted in the Physical Institute of UFF (Brazil) to produce the gas ionization by radio-frequency are shown and its behaviour when confined by a mirror-geometry magnetic field is studied. The diagnostic is made by a langmuir probe and a prisme spectrogaph is used in order to verify the nature of the ionized helium gas and the degree of purity through its spectral lines. The argon ionization by R.f. is produced in the 'LISA' machine obtain a plasma column of approximatelly 60 cm length and with the Langmuir probe the study of the profile distribution of the plasma parameters such as: electron temperature and density and floating potencial in function of the magnetic field variation is made. The main focus is given to the fundamental electron cyclotron resonance (ECR). A new expression on the ion saturation current (I sub(is)) produced by radiofrequency is developed. (L.C.) [pt

  17. Radio-frequency quadrupole linear accelerator

    International Nuclear Information System (INIS)

    Wangler, T.P.; Stokes, R.H.

    1980-01-01

    The radio-frequency quadrupole (RFQ) is a new linear accelerator concept in which rf electric fields are used to focus, bunch, and accelerate the beam. Because the RFQ can provide strong focusing at low velocities, it can capture a high-current dc ion beam from a low-voltage source and accelerate it to an energy of 1 MeV/nucleon within a distance of a few meters. A recent experimental test at the Los Alamos Scientific Laboratory (LASL) has confirmed the expected performance of this structure and has stimulated interest in a wide variety of applications. The general properties of the RFQ are reviewed and examples of applications of this new accelerator are presented

  18. Effects of 1.84 GHz radio-frequency electromagnetic field on sperm ...

    African Journals Online (AJOL)

    sunny t

    Key words: 1.84 GHz, radio-frequency electromagnetic field (RF-EMF), epididymis, ... Author(s) agree that this article remains permanently open access under the terms of the ..... mouse testis after the long-term administration of nickel in feed.

  19. Patient identification in blood sampling.

    Science.gov (United States)

    Davidson, Anne; Bolton-Maggs, Paula

    The majority of adverse reports relating to blood transfusions result from human error, including misidentification of patients and incorrect labelling of samples. This article outlines best practice in blood sampling for transfusion (but is recommended for all pathology samples) and the role of patient empowerment in improving safety.

  20. Therapeutic effect of radiofrequency ablation on children with supraventricular tachycardia and the risk factors for postoperative recurrence.

    Science.gov (United States)

    Li, Chunli; Jia, Libo; Wang, Zhenzhou; Niu, Ling; An, Xinjiang

    2018-05-01

    The present study investigated the therapeutic effect of radiofrequency ablation on children with supraventricular tachycardia (SVT), and explored the risk factors for postoperative recurrence. A total of 312 patients with pediatric SVT were selected in the Affiliated Children's Hospital of Xuzhou Medical University from April, 2011 to March, 2017. All the patients were subjected to radiofrequency ablation, and clinical data were retrospectively analyzed. Tilt table test was performed before and after treatment, and heart rate, systolic and diastolic blood pressure before and after treatment were compared. Plasma levels of D-dimer (D-D), platelet α-granule membrane protein (GMP-140) and thrombin-antithrombin III complex (TAT) were detected by enzyme-linked immunosorbent assay before treatment, immediately after radiofrequency oblation, and at 1, 3 and 7 days after treatment. Treatment outcomes were compared between the atrioventricular reentrant tachycardia (AVRT) and atrioventricular nodal reentrant tachycardia (AVNRT) groups. Risk factors for postoperative recurrence were analyzed. Supine position heart rate after treatment was not significantly different from that before treatment (P>0.05), while the upright position heart rate was significantly increased after treatment (P0.05). No significant difference in radiofrequency ablation rate, recurrence rate and incidence of complications were found between the AVRT and AVNRT groups (P>0.05). After radiofrequency, the levels of D-D, GMP-140 and TAT ablation showed an upward trend, but decreased at day 7 to reach preoperative levels. Logistic regression analysis revealed that residual slow pathway (OR=6.718, P=0.005) and inaccurate targeting (OR=2.815, P=0.007) were independent risk factors for postoperative recurrence (Pradiofrequency ablation can damage the cardiac vagal nerve, resulting in an increase in the heart rate after ablation during the course of the tilt table test and changed hemagglutination state

  1. Radiofrequency catheter ablation: A study concerning electrode configuration, lesion size and potential complications

    International Nuclear Information System (INIS)

    Anfinsen, Ole-Gunnar

    1999-01-01

    The study was performed to evaluate different methods of increasing the lesion size in radiofrequency catheter ablation, which is an important issue as the clinical indications for RF ablation are extended. The safety aspects of RF ablation are also studied, both with standard catheters and with experimental ones. The studies have been performed in vitro, in an animal model and in patients. The results are presented in 5 papers with titles of: 1) 'Radiofrequency catheter ablation of procine right atrium: Increased lesion size with bipolar two-catheter technique compared to unipolar application in vitro and in vivo. 2) Bipolar radiofrequency catheter ablation creates confluent lesions at a larger interelectrode spacing than does unipolar ablation from two electrodes in porcine heart. 3) Temperature-controlled radiofrequency catheter ablation with a 10 mm tip electrode creates larger lesions without charring in the porcine heart. 4) Radiofrequency catheter ablation in vitro: The difference between tissue and catheter tip temperature depends on location of the temperature sensor. 5) The activation of platelet function, coagulation and fibrinolysis during radiofrequency catheter ablation in heparin zed patients. The main conclusions are: 1) Large RF lesions may be created either by using larger electrodes and more power in the unipolar mode, or by changing the electrode configuration and thereby the geometry of the electrical field during RF current delivery. Both the 10 mm unipolar, the dielectrode and the bipolar mode showed feasible in porcine IVC-TV isthmus and right atrial free wall ablations, but the gain in lesion length was most pronounced in the bipolar mode. 2) Crater formation and intramural haemorrhages may complicate RF ablation using high current density in the right atrial free wall. In our study this was observed with 10 mm unipolar and bipolar two-catheter ablation. Phrenic nerve injury and lesions of the adjacent pulmonary tissue are risks related to

  2. Radiofrequency catheter ablation: A study concerning electrode configuration, lesion size and potential complications

    Energy Technology Data Exchange (ETDEWEB)

    Anfinsen, Ole-Gunnar

    1999-07-01

    The study was performed to evaluate different methods of increasing the lesion size in radiofrequency catheter ablation, which is an important issue as the clinical indications for RF ablation are extended. The safety aspects of RF ablation are also studied, both with standard catheters and with experimental ones. The studies have been performed in vitro, in an animal model and in patients. The results are presented in 5 papers with titles of: 1) 'Radiofrequency catheter ablation of procine right atrium: Increased lesion size with bipolar two-catheter technique compared to unipolar application in vitro and in vivo. 2) Bipolar radiofrequency catheter ablation creates confluent lesions at a larger interelectrode spacing than does unipolar ablation from two electrodes in porcine heart. 3) Temperature-controlled radiofrequency catheter ablation with a 10 mm tip electrode creates larger lesions without charring in the porcine heart. 4) Radiofrequency catheter ablation in vitro: The difference between tissue and catheter tip temperature depends on location of the temperature sensor. 5) The activation of platelet function, coagulation and fibrinolysis during radiofrequency catheter ablation in heparin zed patients. The main conclusions are: 1) Large RF lesions may be created either by using larger electrodes and more power in the unipolar mode, or by changing the electrode configuration and thereby the geometry of the electrical field during RF current delivery. Both the 10 mm unipolar, the dielectrode and the bipolar mode showed feasible in porcine IVC-TV isthmus and right atrial free wall ablations, but the gain in lesion length was most pronounced in the bipolar mode. 2) Crater formation and intramural haemorrhages may complicate RF ablation using high current density in the right atrial free wall. In our study this was observed with 10 mm unipolar and bipolar two-catheter ablation. Phrenic nerve injury and lesions of the adjacent pulmonary tissue are risks

  3. Pregnancy outcomes after paternal radiofrequency field exposure aboard fast patrol boats.

    Science.gov (United States)

    Baste, Valborg; Moen, Bente E; Oftedal, Gunnhild; Strand, Leif Age; Bjørge, Line; Mild, Kjell Hansson

    2012-04-01

    To investigate adverse reproductive outcomes among male employees in the Royal Norwegian Navy exposed to radiofrequency electromagnetic fields aboard fast patrol boats. Cohort study of Royal Norwegian Navy servicemen linked to the Medical Birth Registry of Norway, including singleton offspring born between 1967 and 2008 (n = 37,920). Exposure during the last 3 months before conception (acute) and exposure more than 3 months before conception (nonacute) were analyzed. Perinatal mortality and preeclampsia increased after service aboard fast patrol boats during an acute period and also after increased estimated radiofrequency exposure during an acute period, compared with service aboard other vessels. No associations were found between nonacute exposure and any of the reproductive outcomes. Paternal work aboard fast patrol boats during an acute period was associated with perinatal mortality and preeclampsia, but the cause is not clear.

  4. Radiofrequency thermal ablation of a metastatic lung nodule

    Energy Technology Data Exchange (ETDEWEB)

    Highland, Adrian M. [Department of Clinical Radiology, Hull Royal Infirmary, Anlaby Road, Hull, HU3 2JZ (United Kingdom); Mack, Paul [Diana Princess of Wales Hospital, Scartho Road, Grimsby, DN33 2BA (United Kingdom); Breen, David J. [Department of Radiology, Southampton University Hospitals, Tremona Road, Southampton, SO16 6YD (United Kingdom)

    2002-07-01

    Pulmonary metastases are a common finding in patients with colonic adenocarcinoma. We report the treatment of a metastatic lung nodule with radiofrequency (RF) ablation under CT guidance. This case illustrates the use of RF ablation in a patient in whom surgical resection was no longer possible and where chemotherapy was unlikely to produce benefit. This technique may offer a viable method of cytoreduction when other treatments have not succeeded. (orig.)

  5. Radiofrequency thermal ablation of a metastatic lung nodule

    International Nuclear Information System (INIS)

    Highland, Adrian M.; Mack, Paul; Breen, David J.

    2002-01-01

    Pulmonary metastases are a common finding in patients with colonic adenocarcinoma. We report the treatment of a metastatic lung nodule with radiofrequency (RF) ablation under CT guidance. This case illustrates the use of RF ablation in a patient in whom surgical resection was no longer possible and where chemotherapy was unlikely to produce benefit. This technique may offer a viable method of cytoreduction when other treatments have not succeeded. (orig.)

  6. Diaphragmatic Hernia After Radiofrequency Ablation for Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Yoshimatsu, Rika; Matsushima, Shigenori; Tanaka, Osamu; Miura, Hiroshi; Nishimura, Tsunehiko

    2011-01-01

    We describe a 71-year-old woman with a hepatocellular carcinoma who underwent percutaneous radiofrequency ablation (RF) with a single internally cooled electrode under computed tomography (CT) fluoroscopic guidance. Nine months after the procedure, CT images showed herniation of the large intestine into the right pleural cavity. To our knowledge this complication of RF performed with a single internally cooled electrode under CT guidance has not been previously reported.

  7. On plate graphite supported sample processing for simultaneous lipid and protein identification by matrix assisted laser desorption ionization mass spectrometry.

    Science.gov (United States)

    Calvano, Cosima Damiana; van der Werf, Inez Dorothé; Sabbatini, Luigia; Palmisano, Francesco

    2015-05-01

    The simultaneous identification of lipids and proteins by matrix assisted laser desorption ionization-mass spectrometry (MALDI-MS) after direct on-plate processing of micro-samples supported on colloidal graphite is demonstrated. Taking advantages of large surface area and thermal conductivity, graphite provided an ideal substrate for on-plate proteolysis and lipid extraction. Indeed proteins could be efficiently digested on-plate within 15 min, providing sequence coverages comparable to those obtained by conventional in-solution overnight digestion. Interestingly, detection of hydrophilic phosphorylated peptides could be easily achieved without any further enrichment step. Furthermore, lipids could be simultaneously extracted/identified without any additional treatment/processing step as demonstrated for model complex samples such as milk and egg. The present approach is simple, efficient, of large applicability and offers great promise for protein and lipid identification in very small samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Diverse radiofrequency sensitivity and radiofrequency effects of mobile or cordless phone near fields exposure in Drosophila melanogaster.

    Science.gov (United States)

    Geronikolou, Styliani; Zimeras, Stelios; Davos, Constantinos H; Michalopoulos, Ioannis; Tsitomeneas, Stephanos

    2014-01-01

    The impact of electromagnetic fields on health is of increasing scientific interest. The aim of this study was to examine how the Drosophila melanogaster animal model is affected when exposed to portable or mobile phone fields. Two experiments have been designed and performed in the same laboratory conditions. Insect cultures were exposed to the near field of a 2G mobile phone (the GSM 2G networks support and complement in parallel the 3G wide band or in other words the transmission of information via voice signals is served by the 2G technology in both mobile phones generations) and a 1880 MHz cordless phone both digitally modulated by human voice. Comparison with advanced statistics of the egg laying of the second generation exposed and non-exposed cultures showed limited statistical significance for the cordless phone exposed culture and statistical significance for the 900 MHz exposed insects. We calculated by physics, simulated and illustrated in three dimensional figures the calculated near fields of radiation inside the experimenting vials and their difference. Comparison of the power of the two fields showed that the difference between them becomes null when the experimental cylinder radius and the height of the antenna increase. Our results suggest a possible radiofrequency sensitivity difference in insects which may be due to the distance from the antenna or to unexplored intimate factors. Comparing the near fields of the two frequencies bands, we see similar not identical geometry in length and height from the antenna and that lower frequencies tend to drive to increased radiofrequency effects.

  9. Radiofrequency-assisted Liposuction for Arm Contouring: Technique under Local Anesthesia

    Directory of Open Access Journals (Sweden)

    Spero Theodorou, MD

    2013-08-01

    Conclusions: In appropriately selected patients, RFAL arm contouring under local anesthesia represents an alternative procedure with acceptably low morbidity and high patient satisfaction. To achieve consistent results while minimizing complications, consideration to anatomic details, infiltration of the local anesthetic, and application of the radiofrequency energy must be given.

  10. Radiofrequency ablation of liver tumors by using monopolar perfusion electrode:an analysis of therapeutic results

    International Nuclear Information System (INIS)

    Luo Rongguang; Gu Yangkui; Gao Fei; Zhang Liang; Zhao Ming; Fan Weijun; Wu Peihong; Huang Jinhua

    2010-01-01

    Objective: To investigate the clinical value of CT-guided radiofrequency ablation by using monopolar perfusion electrode in treating liver tumors. Methods: From January 2008 to December 2008, 24 patients with 37 lesions of liver tumors were treated with radiofrequency ablation by using monopolar perfusion electrode (RITA UniBlate). Of the 24 patients,solitary lesion was seen in 14, two lesions in 7 and three lesions in 3. Among 37 lesions,the maximum diameter of the lesion ≤ 3 cm, 3.1∼5 cm and > 5 cm was determined in 24, 8 and 5, respectively. The changes of the tumor size and the AFP level were observed. A follow-up lasting for 12 months was conducted. Results: After radiofrequency ablation twenty-two lesions (22/37, 59.5%) were completely ablated, of which nineteen tumors (19/24, 79.2%) were smaller than 3 cm in diameter, two tumors (2 / 8, 25%) had a diameter between 3.1 cm and 5 cm, one tumor (1 / 5, 20%) was larger than 5 cm. Fifteen tumors (15 / 37, 40.5%) were not completely ablated. During the follow-up period of 12 months, fifteen patients (15 / 24, 62.5%) remained alive and nine patients died, of whom the survival time was less than 6 months in six and was 6 -12 months in 4. After radiofrequency ablation, the AFP level decreased to normal level in 5 patients (5 / 10, 50%), and mild decrease of AFP, but still higher than normal,was seen in 3 patients (3 / 10, 30%). Of 10 patients who had a positive AFP test, 2 (2 / 10, 10%) showed a continuous rise in the AFP level. After radiofrequency ablation, one patient developed a minor hepatic subcapsular bleeding,and all patients complained of different degrees of fever and upper abdominal pain. Conclusion: CT-guided radiofrequency ablation by using monopolar perfusion electrode is a minimally-invasive technique with reliable short-term results and fewer complications. Therefore, it is a safe and effective local treatment for liver cancer. For tumors smaller than 3 cm in diameter complete ablation can be

  11. The T-lock: automated compensation of radio-frequency induced sample heating

    International Nuclear Information System (INIS)

    Hiller, Sebastian; Arthanari, Haribabu; Wagner, Gerhard

    2009-01-01

    Modern high-field NMR spectrometers can stabilize the nominal sample temperature at a precision of less than 0.1 K. However, the actual sample temperature may differ from the nominal value by several degrees because the sample heating caused by high-power radio frequency pulses is not readily detected by the temperature sensors. Without correction, transfer of chemical shifts between different experiments causes problems in the data analysis. In principle, the temperature differences can be corrected by manual procedures but this is cumbersome and not fully reliable. Here, we introduce the concept of a 'T-lock', which automatically maintains the sample at the same reference temperature over the course of different NMR experiments. The T-lock works by continuously measuring the resonance frequency of a suitable spin and simultaneously adjusting the temperature control, thus locking the sample temperature at the reference value. For three different nuclei, 13 C, 17 O and 31 P in the compounds alanine, water, and phosphate, respectively, the T-lock accuracy was found to be <0.1 K. The use of dummy scan periods with variable lengths allows a reliable establishment of the thermal equilibrium before the acquisition of an experiment starts

  12. Is radiofrequency ablation of varicose veins a valuable option? A systematic review of the literature with a cost analysis.

    Science.gov (United States)

    Poder, Thomas G; Fisette, Jean-François; Bédard, Suzanne K; Despatis, Marc-Antoine

    2018-04-01

    Since the 1990s, new techniques for the treatment of varicose veins have emerged, including radiofrequency ablation (RFA) and laser treatment. We performed a study to compare the safety, efficacy and outcomes of RFA compared to those of open surgery and laser ablation for the treatment of varicose veins. We also carried out a cost analysis of RFA compared to open surgery to assess whether RFA could help free up operating room time by being performed in an outpatient context. We conducted a systematic literature review (publication date May 2010-September 2013 for articles in English, January 1991-September 2013 for those in French). We used several checklists to measure the quality of the studies. We also collected data on costing. The literature search identified 924 publications, of which 38 were retained for analysis: 15 literature reviews, 1 good-practice guideline and 22 new primary studies. The overall level of evidence was low to moderate owing to the limited sample sizes, lack of information on patient characteristics and lack of standardization of the outcome measures. However, the results obtained are consistent from study to study. In the short and medium term, RFA is considered as effective as open surgery or laser treatment (moderate level of evidence) and presents fewer major and minor complications than open surgery (low level of evidence). Radiofrequency ablation can be performed on an outpatient basis. We calculated that RFA would be about $110-$220 more expensive per patient than open surgery. Radiofrequency ablation is a valuable alternative to open surgery and would free up operating room time in a context of low accessibility.

  13. Is radiofrequency ablation of varicose veins a valuable option? A systematic review of the literature with a cost analysis

    Science.gov (United States)

    Fisette, Jean-François; Bédard, Suzanne K.; Despatis, Marc-Antoine

    2018-01-01

    Background Since the 1990s, new techniques for the treatment of varicose veins have emerged, including radiofrequency ablation (RFA) and laser treatment. We performed a study to compare the safety, efficacy and outcomes of RFA compared to those of open surgery and laser ablation for the treatment of varicose veins. We also carried out a cost analysis of RFA compared to open surgery to assess whether RFA could help free up operating room time by being performed in an outpatient context. Methods We conducted a systematic literature review (publication date May 2010–September 2013 for articles in English, January 1991–September 2013 for those in French). We used several checklists to measure the quality of the studies. We also collected data on costing. Results The literature search identified 924 publications, of which 38 were retained for analysis: 15 literature reviews, 1 good-practice guideline and 22 new primary studies. The overall level of evidence was low to moderate owing to the limited sample sizes, lack of information on patient characteristics and lack of standardization of the outcome measures. However, the results obtained are consistent from study to study. In the short and medium term, RFA is considered as effective as open surgery or laser treatment (moderate level of evidence) and presents fewer major and minor complications than open surgery (low level of evidence). Radiofrequency ablation can be performed on an outpatient basis. We calculated that RFA would be about $110–$220 more expensive per patient than open surgery. Conclusion Radiofrequency ablation is a valuable alternative to open surgery and would free up operating room time in a context of low accessibility. PMID:29582749

  14. Three Cycles of Radiofrequency Ablation Are More Efficacious Than Two in the Management of Morton's Neuroma.

    Science.gov (United States)

    Brooks, David; Parr, Adam; Bryceson, William

    2018-04-01

    Morton's neuroma is a common cause of forefoot pain. Outcomes of conservative therapy are mixed and many patients undergo operative intervention. Radiofrequency ablation has recently gained favor as a treatment option, although the optimal regime is unknown. This study investigates the effectiveness of 2 versus 3 cycles of radiofrequency ablation for the treatment of Morton's neuroma. We surveyed a cohort of patients with Morton's neuroma who had progressed to radiofrequency ablation after failed conservative treatment. Patients received either 2 or 3 cycles of radiofrequency ablation by a single surgeon. We assessed patients based on their change in numerical pain rating scale, symptom improvement, complications, and progression to surgical excision through a series of telephone interviews. Outcomes between the 2 treatment arms were compared by parametric tests. Twenty-eight patients were included in the study. Eighteen patients with 21 neuromas received 2 cycles and 10 patients with 11 neuromas received 3 cycles. Mean time of follow-up was 12.9 months. Overall, 88% of patients were either very or moderately satisfied with their outcome. In patients who received 2 cycles mean numerical pain scores decreased from 7.9 ± 1.1 to 3.4 ± 2.4 postprocedure. Three patients progressed to operative excision. In patients who received 3 cycles, numerical pain scores decreased from 8.0 ± 1.0 to 1.5 ± 2.0 postprocedure. One patient progressed to operative excision. Patients who received 3 cycles had reduced medium-term pain postoperatively compared with 2 cycles (3.4 ± 2.4 vs 1.5 ± 2.0, P = .011). Radiofrequency ablation provides a high rate of patient satisfaction in the treatment of Morton's neuroma with few side effects. It appears that 3 cycles may be superior to 2 cycles but a randomized controlled trial will be required to confirm these results. Intervention, Level III: Comparative study without concurrent controls.

  15. Temperature responsive porous silicon nanoparticles for cancer therapy - spatiotemporal triggering through infrared and radiofrequency electromagnetic heating.

    Science.gov (United States)

    Tamarov, Konstantin; Xu, Wujun; Osminkina, Liubov; Zinovyev, Sergey; Soininen, Pasi; Kudryavtsev, Andrey; Gongalsky, Maxim; Gaydarova, Azha; Närvänen, Ale; Timoshenko, Victor; Lehto, Vesa-Pekka

    2016-11-10

    One critical functionality of the carrier system utilized in targeted drug delivery is its ability to trigger the release of the therapeutic cargo once the carrier has reached its target. External triggering is an alluring approach as it can be applied in a precise spatiotemporal manner. In the present study, we achieved external triggering through the porous silicon (PSi) nanoparticles (NPs) by providing a pulse of infrared or radiofrequency radiation. The NPs were grafted with a temperature responsive polymer whose critical temperature was tailored to be slightly above 37°C. The polymer coating improved the biocompatibility of the NPs significantly in comparison with their uncoated counterparts. Radiation induced a rapid temperature rise, which resulted in the collapse of the polymer chains facilitating the cargo release. Both infrared and radiofrequency radiation were able to efficiently trigger the release of the encapsulated drug in vitro and induce significant cell death in comparison to the control groups. Radiofrequency radiation was found to be more efficient in vitro, and the treatment efficacy was verified in vivo in a lung carcinoma (3LL) mice model. After a single intratumoral administration of the carrier system combined with radiofrequency radiation, there was clear suppression of the growth of the carcinoma and a prolongation of the survival time of the animals. The temperature responsive (TR) polymer grafted on the surface of porous silicon nanoparticles (PSi NPs) changes its conformation in response to the heating induced by infrared or radiofrequency radiation. The conformation change allows the loaded doxorubicin to escape from the pores, achieving controlled drug release from TR PSi NPs, which displayed efficacy against malignant cells both in vitro and in vivo. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Accurate Depth of Radiofrequency-Induced Lesions in Renal Sympathetic Denervation Based on a Fine Histological Sectioning Approach in a Porcine Model.

    Science.gov (United States)

    Sakaoka, Atsushi; Terao, Hisako; Nakamura, Shintaro; Hagiwara, Hitomi; Furukawa, Toshihito; Matsumura, Kiyoshi; Sakakura, Kenichi

    2018-02-01

    Ablation lesion depth caused by radiofrequency-based renal denervation (RDN) was limited to radiofrequency-RDN cannot ablate a substantial percentage of renal sympathetic nerves. We aimed to define the true lesion depth achieved with radiofrequency-RDN using a fine sectioning method and to investigate biophysical parameters that could predict lesion depth. Radiofrequency was delivered to 87 sites in 14 renal arteries from 9 farm pigs at various ablation settings: 2, 4, 6, and 9 W for 60 seconds and 6 W for 120 seconds. Electric impedance and electrode temperature were recorded during ablation. At 7 days, 2470 histological sections were obtained from the treated arteries. Maximum lesion depth increased at 2 to 6 W, peaking at 6.53 (95% confidence interval, 4.27-8.78) mm under the 6 W/60 s condition. It was not augmented by greater power (9 W) or longer duration (120 seconds). There were statistically significant tendencies at 6 and 9 W, with higher injury scores in the media, nerves, arterioles, and fat. Maximum lesion depth was positively correlated with impedance reduction and peak electrode temperature (Pearson correlation coefficients were 0.59 and 0.53, respectively). Lesion depth was 6.5 mm for radiofrequency-RDN at 6 W/60 s. The impedance reduction and peak electrode temperature during ablation were closely associated with lesion depth. Hence, these biophysical parameters could provide prompt feedback during radiofrequency-RDN procedures in the clinical setting. © 2018 The Authors.

  17. Results of Cryoenergy and Radiofrequency-Based Catheter Ablation for Treating Ventricular Arrhythmias Arising From the Papillary Muscles of the Left Ventricle, Guided by Intracardiac Echocardiography and Image Integration.

    Science.gov (United States)

    Rivera, Santiago; Ricapito, Maria de la Paz; Tomas, Leandro; Parodi, Josefina; Bardera Molina, Guillermo; Banega, Rodrigo; Bueti, Pablo; Orosco, Agustin; Reinoso, Marcelo; Caro, Milagros; Belardi, Diego; Albina, Gaston; Giniger, Alberto; Scazzuso, Fernando

    2016-04-01

    Catheter radiofrequency ablation of ventricular arrhythmias (VAs) arising from the left ventricle's papillary muscles has been associated with inconsistent results. The use of cryoenergy versus radiofrequency has not been compared yet. This study compares outcomes and complications of catheter ablation of VA from the papillary muscles of the left ventricle with either cryoenergy or radiofrequency. Twenty-one patients (40±12 years old; 47% males; median ejection fraction 59±7.3%) with drug refractory premature ventricular contractions or ventricular tachycardia underwent catheter cryoablation or radiofrequency ablation. VAs were localized using 3-dimensional mapping, multidetector computed tomography, and intracardiac echocardiography, with arrhythmia foci being mapped at either the anterolateral papillary muscle or posteromedial papillary muscles of the left ventricle. Focal ablation was performed using an 8-mm cryoablation catheter or a 4-mm open-irrigated radiofrequency catheter, via transmitral approach. Acute success rate was 100% for cryoenergy (n=12) and 78% for radiofrequency (n=9; P=0.08). Catheter stability was achieved in all patients (100%) treated with cryoenergy, and only in 2 (25%) patients treated with radiofrequency (P=0.001). Incidence of multiple VA morphologies was observed in 7 patients treated with radiofrequency (77.7%), whereas none was observed in those treated with cryoenergy (P=0.001). VA recurrence at 6 months follow-up was 0% for cryoablation and 44% for radiofrequency (P=0.03). Cryoablation was associated with higher success rates and lower recurrence rates than radiofrequency catheter ablation, better catheter stability, and lesser incidence of polymorphic arrhythmias. © 2016 American Heart Association, Inc.

  18. Giving Students Control over Their Learning; from Self-guided Museum Visits and Field Trips to Using Scanning Technology to Link Content to Earth Samples

    Science.gov (United States)

    Kirkby, K. C.; Phipps, M.

    2011-12-01

    While it may seem counterintuitive, sometimes stepping back is one of the more effective pedagogical approaches instructors can make. On museum visits, an instructor's presence fundamentally alters students' experiences and can curtail student learning by limiting questions or discouraging students from exploring their own interests. Students often rely on the instructor and become passive observers, rather than engaged learners. As an alternative to instructor-led visits, self-guided student explorations of museum exhibits proved to be both popular and pedagogically effective. On pre-instruction and post-instruction surveys, these ungraded, self-guided explorations match or exceed the efficacy of traditional graded lab instruction and completely eclipse gains normally achieved by traditional lecture instruction. In addition, these explorations achieve the remarkable goal of integrating undergraduate earth science instruction into students' social lives. Based on the success of the self-guided museum explorations, this fall saw the debut of an attempt to expand this concept to field experiences. A self-guided student field exploration of Saint Anthony Falls focuses on the intersections of geological processes with human history. Students explore the waterfalls' evolution, its early interpretation by 18th and 19th century Dakota and Euro-America societies, and its subsequent social and economic impacts on Upper Midwest societies. Self-guided explorations allow students to explore field settings on their own or with friends and family in a more relaxed manner. At the same time, these explorations give students control over, and responsibility for, their own learning - a powerful pedagogical approach. Student control over their learning is also the goal of an initiative to use scanning technologies, such as linear bar codes, 2D barcodes and radio-frequency identification (RFID), to revolutionize sample identification and study. Scanning technology allows students to

  19. Identification and quantification of cardiac glycosides in blood and urine samples by HPLC/MS/MS.

    Science.gov (United States)

    Guan, F; Ishii, A; Seno, H; Watanabe-Suzuki, K; Kumazawa, T; Suzuki, O

    1999-09-15

    Cardiac glycosides (CG) are of forensic importance because of their toxicity and the fact that very limited methods are available for identification of CG in biological samples. In this study, we have developed an identification and quantification method for digoxin, digitoxin, deslanoside, digoxigenin, and digitoxigenin by high-performance liquid chromatography tandem mass spectrometry (HPLC/MS/MS). CG formed abundant [M + NH4]+ ions and much less abundant [M + H]+ ions as observed with electrospray ionization (ESI) source and ammonium formate buffer. Under mild conditions for collision-induced dissociation (CID), each [M + NH4]+ ion fragmented to produce a dominant daughter ion, which was essential to the sensitive method of selected reaction monitoring (SRM) quantification of CG achieved in this study. SRM was compared with selected ion monitoring (SIM) regarding the effects of sample matrixes on the methodology. SRM produced lower detection limits with biological samples than SIM, while both methods produced equal detection limits with CG standards. On the basis of the HPLC/MS/MS results for CG, we have proposed some generalized points for conducting sensitive SRM measurements, in view of the property of analytes as well as instrumental conditions such as the type of HPLC/MS interface and CID parameters. Analytes of which the molecular ion can produce one abundant daughter ion with high yield under CID conditions may be sensitively measured by SRM. ESI is the most soft ionization source developed so far and can afford formation of the fragile molecular ions that are necessary for sensitive SRM detection. Mild CID conditions such as low collision energy and low pressure of collision gas favor production of an abundant daughter ion that is essential to sensitive SRM detection. This knowledge may provide some guidelines for conducting sensitive SRM measurements of very low concentrations of drugs or toxicants in biological samples.

  20. Comparing different post-mortem human samples as DNA sources for downstream genotyping and identification.

    Science.gov (United States)

    Calacal, Gayvelline C; Apaga, Dame Loveliness T; Salvador, Jazelyn M; Jimenez, Joseph Andrew D; Lagat, Ludivino J; Villacorta, Renato Pio F; Lim, Maria Cecilia F; Fortun, Raquel D R; Datar, Francisco A; De Ungria, Maria Corazon A

    2015-11-01

    The capability of DNA laboratories to perform genotyping procedures from post-mortem remains, including those that had undergone putrefaction, continues to be a challenge in the Philippines, a country characterized by very humid and warm conditions all year round. These environmental conditions accelerate the decomposition of human remains that were recovered after a disaster and those that were left abandoned after a crime. When considerable tissue decomposition of human remains has taken place, there is no other option but to extract DNA from bone and/or teeth samples. Routinely, femur shafts are obtained from recovered bodies for human identification because the calcium matrix protects the DNA contained in the osteocytes. In the Philippines, there is difficulty in collecting femur samples after natural disasters or even human-made disasters, because these events are usually characterized by a large number of fatalities. Identification of casualties is further delayed by limitation in human and material resources. Hence, it is imperative to test other types of biological samples that are easier to collect, transport, process and store. We analyzed DNA that were obtained from body fluid, bone marrow, muscle tissue, clavicle, femur, metatarsal, patella, rib and vertebral samples from five recently deceased untreated male cadavers and seven male human remains that were embalmed, buried for ∼ 1 month and then exhumed. The bodies had undergone different environmental conditions and were in various stages of putrefaction. A DNA extraction method utilizing a detergent-washing step followed by an organic procedure was used. The utility of bone marrow and vitreous fluid including bone marrow and vitreous fluid that was transferred on FTA(®) cards and subjected to autosomal STR and Y-STR DNA typing were also evaluated. DNA yield was measured and the presence or absence of PCR inhibitors in DNA extracts was assessed using Plexor(®)HY. All samples were amplified using

  1. Ion transmission in a linear radiofrequency spectrometer

    International Nuclear Information System (INIS)

    Gomet, J.-C.

    1975-01-01

    A linear radiofrequency spectrometer is used for the purpose of experimental determination of the absolute ionization cross sections of various ions obtained by electron impact on polyatomic molecules. The transmission of the apparatus is studied: it does not only depend on the mass resolution of the spectrometer, but also on the nature of ions. It is affected by charge transfers, especially for the parent ions. An empiric way of correction of the apparatus function is given which allows the use at 10 -6 Torr [fr

  2. Radio-frequency characteristic variation of interdigital capacitor having multilayer graphene of various widths

    Science.gov (United States)

    Lee, Hee-Jo; Hong, Young-Pyo

    2018-03-01

    In this paper, a radio-frequency circuit model of an interdigital capacitor (IDC) with a multilayer graphene (MLG) width variation is proposed. The circuit model with three sample configurations, i.e., a bare IDC, IDC-MLG with a width of 5 μm, and IDC-MLG with a width of 20 μm, is constructed via a fitted method based on the measured samples. The simulated results of the circuit model are validated through the RF characteristics, e.g., the capacitance and the self-resonance frequency, of the measured samples. From the circuit model, all samples show not only a similar capacitance behavior but also an identical self-resonance frequency of 10 GHz. Moreover, the R, L, and C values of MLG with a 5 μm width (MLG with a 20 μm width) alone are approximately 0.8 kΩ (0.5 kΩ), 0.5 nH (0.9 nH), and 0.3 pF (0.1 pF), respectively. As a result, we find that the simulated results are in good agreement with RF characteristics of the measured samples. In the future, we expect that the proposed circuit model of an IDC with MLG will offer assistance with performance predictions of diverse IDC-based 2D material applications, such as biosensors and gas sensors, as well as supercapacitors.

  3. Adverse effects of radiofrequency ablation of liver tumours in the Netherlands

    NARCIS (Netherlands)

    Jansen, M. C.; van Duijnhoven, F. H.; van Hillegersberg, R.; Rijken, A.; van Coevorden, F.; van der Sijp, J.; Prevoo, W.; van Gulik, T. M.

    2005-01-01

    Background: Radiofrequency ablation (RFA) is a new treatment for liver tumours. Complications encountered after RFA in the Netherlands were evaluated in the present study. Methods: Between June 1999 and November 2003 patients undergoing RFA of irresectable liver tumours in eight medical centres were

  4. Radiofrequency ablation of fast ventricular tachycardia causing an ICD storm in an infant with hypertrophic cardiomyopathy.

    Science.gov (United States)

    Ergul, Yakup; Ozyilmaz, Isa; Bilici, Meki; Ozturk, Erkut; Haydin, Sertaç; Guzeltas, Alper

    2018-04-01

    An implantable cardioverter defibrillator (ICD) storm involves very frequent arrhythmia episodes and ICD shocks, and it is associated with poor short-term and long-term prognosis. Radiofrequency catheter ablation can be used as an effective rescue treatment for patients with an ICD storm. To our knowledge, this is the first report of an infant with hypertrophic cardiomyopathy presenting with an ICD storm and undergoing successful radiofrequency catheter ablation salvage treatment for the fast left posterior fascicular ventricular tachycardia. © 2017 Wiley Periodicals, Inc.

  5. Anthropogenic radiofrequency electromagnetic fields as an emerging threat to wildlife orientation.

    Science.gov (United States)

    Balmori, Alfonso

    2015-06-15

    The rate of scientific activity regarding the effects of anthropogenic electromagnetic radiation in the radiofrequency (RF) range on animals and plants has been small despite the fact that this topic is relevant to the fields of experimental biology, ecology and conservation due to its remarkable expansion over the past 20 years. Current evidence indicates that exposure at levels that are found in the environment (in urban areas and near base stations) may particularly alter the receptor organs to orient in the magnetic field of the earth. These results could have important implications for migratory birds and insects, especially in urban areas, but could also apply to birds and insects in natural and protected areas where there are powerful base station emitters of radiofrequencies. Therefore, more research on the effects of electromagnetic radiation in nature is needed to investigate this emerging threat. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Bipolar and monopolar radiofrequency treatment of osteoarthritic knee articular cartilage: acute and temporal effects on cartilage compressive stiffness, permeability, cell synthesis, and extracellular matrix composition.

    Science.gov (United States)

    Cook, James L; Kuroki, Keiichi; Kenter, Keith; Marberry, Kevin; Brawner, Travis; Geiger, Timothy; Jayabalan, Prakash; Bal, B Sonny

    2004-04-01

    The cellular, biochemical, biomechanical, and histologic effects of radiofrequency-generated heat on osteoarthritic cartilage were assessed. Articular cartilage explants (n=240) from 26 patients undergoing total knee arthroplasty were divided based on Outerbridge grade (I or II/III) and randomly assigned to receive no treatment (controls) or monopolar or bipolar radiofrequency at 15 or 30 W. Both potentially beneficial and harmful effects of radiofrequency treatment of articular cartilage were noted. It will be vital to correlate data from in vitro and in vivo study of radiofrequency thermal chondroplasty to determine the clinical usefulness of this technique.

  7. Radiofrequency (thermal) ablation versus no intervention or other interventions for hepatocellular carcinoma

    DEFF Research Database (Denmark)

    Weis, Sebastian; Franke, Annegret; Mössner, Joachim

    2013-01-01

    Hepatocellular carcinoma is the fifth most common cancer worldwide. Percutaneous interventional therapies, such as radiofrequency (thermal) ablation (RFA), have been developed for early hepatocellular carcinoma. RFA competes with other interventional techniques such as percutaneous ethanol...

  8. Sacroiliac joint pain: Prospective, randomised, experimental and comparative study of thermal radiofrequency with sacroiliac joint block.

    Science.gov (United States)

    Cánovas Martínez, L; Orduña Valls, J; Paramés Mosquera, E; Lamelas Rodríguez, L; Rojas Gil, S; Domínguez García, M

    2016-05-01

    To compare the analgesic effects between the blockade and bipolar thermal radiofrequency in the treatment of sacroiliac joint pain. Prospective, randomised and experimental study conducted on 60 patients selected in the two hospitals over a period of nine months, who had intense sacroiliac joint pain (Visual Analogue Scale [VAS]>6) that lasted more than 3 months. Patients were randomised into three groups (n=20): Group A (two intra-articular sacroiliac injections of local anaesthetic/corticosteroid guided by ultrasound in 7 days). Group B: conventional bipolar radiofrequency "palisade". Target points were the lateral branch nerves of S1, S2, and S3, distance needles 1cm. Group C: modified bipolar radiofrequency "palisade" (needle distance >1cm). Patients were evaluated at one month, three months, and one year. Demographic data, VAS reduction, and side effects of the techniques were assessed. One month after the treatment, pain reduction was >50% in the three groups PDolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Performance of an iodine-fueled radio-frequency ion-thruster

    Science.gov (United States)

    Holste, Kristof; Gärtner, Waldemar; Zschätzsch, Daniel; Scharmann, Steffen; Köhler, Peter; Dietz, Patrick; Klar, Peter J.

    2018-01-01

    Two sets of performance data of the same radio-frequency ion-thruster (RIT) have been recorded using iodine and xenon, respectively, as propellant. To characterize the thruster's performance, we have recorded the radio-frequency DC-power, required for yielding preset values of the extracted ion-beam currents, as a function of mass flow. For that purpose, an iodine mass flow system had to be developed, calibrated, and integrated into a newly-built test facility for studying corrosive propellants. The performance mappings for iodine and xenon differ significantly despite comparable operation conditions. At low mass flows, iodine exhibits the better performance. The situation changes at higher mass flows where the performance of iodine is significantly poorer than that of xenon. The reason is very likely related to the molecular nature of iodine. Our results show that iodine as propellant is compatible with RIT technology. Furthermore, it is a viable alternative as propellant for dedicated space missions. In particular, when taking into account additional benefits such as possible storage as a solid and its low price the use of iodine as propellant in ion thrusters is competitive.

  10. Identification and characterization of unrecognized viruses in stool samples of non-polio acute flaccid paralysis children by simplified VIDISCA

    NARCIS (Netherlands)

    Shaukat, Shahzad; Angez, Mehar; Alam, Muhammad Masroor; Jebbink, Maarten F.; Deijs, Martin; Canuti, Marta; Sharif, Salmaan; de Vries, Michel; Khurshid, Adnan; Mahmood, Tariq; van der Hoek, Lia; Zaidi, Syed Sohail Zahoor

    2014-01-01

    The use of sequence independent methods combined with next generation sequencing for identification purposes in clinical samples appears promising and exciting results have been achieved to understand unexplained infections. One sequence independent method, Virus Discovery based on cDNA Amplified

  11. Breakdown criteria due to radio-frequency fields in vacuum. Final report

    International Nuclear Information System (INIS)

    Reid, D.W.; Lohsen, R.A.

    1982-01-01

    The factors that affect the voltage at which vacuum gaps break down are analyzed. Based on the literature and some simplifying assumptions, a functional dependence is hypothesized. The hypothesis is related to a proposed experiment using radio-frequency power to generate the breakdown voltage

  12. Computed tomography findings after radiofrequency ablation in locally advanced pancreatic cancer

    NARCIS (Netherlands)

    Rombouts, Steffi J. E.; Derksen, Tyche C.; Nio, Chung Y.; van Hillegersberg, Richard; van Santvoort, Hjalmar C.; Walma, Marieke S.; Molenaar, Izaak Q.; van Leeuwen, Maarten S.

    2018-01-01

    The purpose of the study was to provide a systematic evaluation of the computed tomography(CT) findings after radiofrequency ablation (RFA) in locally advanced pancreatic cancer(LAPC). Eighteen patients with intra-operative RFA-treated LAPC were included in a prospective case series. All CT-scans

  13. Modulated Raman spectroscopy for enhanced identification of bladder tumor cells in urine samples.

    Science.gov (United States)

    Canetta, Elisabetta; Mazilu, Michael; De Luca, Anna Chiara; Carruthers, Antonia E; Dholakia, Kishan; Neilson, Sam; Sargeant, Harry; Briscoe, Tina; Herrington, C Simon; Riches, Andrew C

    2011-03-01

    Standard Raman spectroscopy (SRS) is a noninvasive technique that is used in the biomedical field to discriminate between normal and cancer cells. However, the presence of a strong fluorescence background detracts from the use of SRS in real-time clinical applications. Recently, we have reported a novel modulated Raman spectroscopy (MRS) technique to extract the Raman spectra from the background. In this paper, we present the first application of MRS to the identification of human urothelial cells (SV-HUC-1) and bladder cancer cells (MGH) in urine samples. These results are compared to those obtained by SRS. Classification using the principal component analysis clearly shows that MRS allows discrimination between Raman spectra of SV-HUC-1 and MGH cells with high sensitivity (98%) and specificity (95%). MRS is also used to distinguish between SV-HUC-1 and MGH cells after exposure to urine for up to 6 h. We observe a marked change in the MRS of SV-HUC-1 and MGH cells with time in urine, indicating that the conditions of sample collection will be important for the application of this methodology to clinical urine samples.

  14. Diverse Radiofrequency Sensitivity and Radiofrequency Effects of Mobile or Cordless Phone near Fields Exposure in Drosophila melanogaster

    Science.gov (United States)

    Geronikolou, Styliani; Zimeras, Stelios; Davos, Constantinos H.; Michalopoulos, Ioannis; Tsitomeneas, Stephanos

    2014-01-01

    Introduction The impact of electromagnetic fields on health is of increasing scientific interest. The aim of this study was to examine how the Drosophila melanogaster animal model is affected when exposed to portable or mobile phone fields. Methods/Results Two experiments have been designed and performed in the same laboratory conditions. Insect cultures were exposed to the near field of a 2G mobile phone (the GSM 2G networks support and complement in parallel the 3G wide band or in other words the transmission of information via voice signals is served by the 2G technology in both mobile phones generations) and a 1880 MHz cordless phone both digitally modulated by human voice. Comparison with advanced statistics of the egg laying of the second generation exposed and non-exposed cultures showed limited statistical significance for the cordless phone exposed culture and statistical significance for the 900 MHz exposed insects. We calculated by physics, simulated and illustrated in three dimensional figures the calculated near fields of radiation inside the experimenting vials and their difference. Comparison of the power of the two fields showed that the difference between them becomes null when the experimental cylinder radius and the height of the antenna increase. Conclusions/Significance Our results suggest a possible radiofrequency sensitivity difference in insects which may be due to the distance from the antenna or to unexplored intimate factors. Comparing the near fields of the two frequencies bands, we see similar not identical geometry in length and height from the antenna and that lower frequencies tend to drive to increased radiofrequency effects. PMID:25402465

  15. Diverse radiofrequency sensitivity and radiofrequency effects of mobile or cordless phone near fields exposure in Drosophila melanogaster.

    Directory of Open Access Journals (Sweden)

    Styliani Geronikolou

    Full Text Available INTRODUCTION: The impact of electromagnetic fields on health is of increasing scientific interest. The aim of this study was to examine how the Drosophila melanogaster animal model is affected when exposed to portable or mobile phone fields. METHODS/RESULTS: Two experiments have been designed and performed in the same laboratory conditions. Insect cultures were exposed to the near field of a 2G mobile phone (the GSM 2G networks support and complement in parallel the 3G wide band or in other words the transmission of information via voice signals is served by the 2G technology in both mobile phones generations and a 1880 MHz cordless phone both digitally modulated by human voice. Comparison with advanced statistics of the egg laying of the second generation exposed and non-exposed cultures showed limited statistical significance for the cordless phone exposed culture and statistical significance for the 900 MHz exposed insects. We calculated by physics, simulated and illustrated in three dimensional figures the calculated near fields of radiation inside the experimenting vials and their difference. Comparison of the power of the two fields showed that the difference between them becomes null when the experimental cylinder radius and the height of the antenna increase. CONCLUSIONS/SIGNIFICANCE: Our results suggest a possible radiofrequency sensitivity difference in insects which may be due to the distance from the antenna or to unexplored intimate factors. Comparing the near fields of the two frequencies bands, we see similar not identical geometry in length and height from the antenna and that lower frequencies tend to drive to increased radiofrequency effects.

  16. Skin tightening with a combined unipolar and bipolar radiofrequency device.

    Science.gov (United States)

    Mayoral, Flor A

    2007-02-01

    Monopolar radiofrequency (RF) devices are well established treatment modalities for tightening facial skin. A 60-year-old woman presented with a desire to tighten the lax skin and improve the appearance of both upper arms. A combination unipolar and bipolar RF device may provide volume reduction as well as skin tightening in the upper arm.

  17. Effects of Pulsed Versus Conventional Versus Combined Radiofrequency for the Treatment of Trigeminal Neuralgia: A Prospective Study.

    Science.gov (United States)

    Elawamy, Abdelraheem; Abdalla, Esam Eldein Mohamed; Shehata, Ghaydaa A

    2017-09-01

    During radiofrequency bursts of energy are applied to nervous tissue. The clinical advantages of this treatment remain unclear. We compared the effectiveness and pain relief for idiopathic trigeminal neuralgia (TN) after continuous radiofrequency (CRF), pulsed radiofrequency (PRF), and combined continuous and pulsed radiofrequency (CCPRF) treatment of the Gasserian ganglion (GG). We conducted a randomized prospective study. Forty-three patients were included. Eleven patients were treated with PRF at 42°C for 10 minutes (PRF group), 12 patients received CRF for 270 seconds at 75 °C (CRF group), and 20 patients received PRF for 10 minutes at 42°C followed by CRF for at 60°C for 270 seconds (CCPRF group). Assuit University Hospital, Pain and Neurology outpatient clinics. Patients were assessed for pain, satisfaction, and consumption of analgesics at baseline and 7 days, one month, 6 months, 12 months, and 24 months after the procedure. The incidence of complications, anesthesia dolorosa, weakness of muscles of mastication, numbness, and technical complications, was evaluated after the procedure. Excellent pain relief was achieved after 6, 12, and 24 months, respectively in 95%, 85%, and 70% of patients with CCPRF; 75%, 75%, and reduced to 50% among patients with CRF; and 82%, reduced to 9.1%, and 0% of patients with PRF. No complications were recorded in 75% of patients in the CCPRF and PRF groups. There was one case of anesthesia dolorosa, 4 cases of masseter muscle weakness, and 5 cases of severe numbness recorded in the CRF group. There was a small number of patients in each group. The best results were observed in the CCPRF group, followed by the CRF group, and then the PRF group.Key words: Pulsed, continuous, radiofrequency, trigeminal neuralgia, Gasserian ganglion.

  18. Probing the fundamental limit of niobium in high radiofrequency fields by dual mode excitation in superconducting radiofrequency cavities

    International Nuclear Information System (INIS)

    Eremeev, Grigory; Geng, Rongli; Palczewski, Ari

    2011-01-01

    We have studied thermal breakdown in several multicell superconducting radiofrequency cavity by simultaneous excitation of two TM 010 passband modes. Unlike measurements done in the past, which indicated a clear thermal nature of the breakdown, our measurements present a more complex picture with interplay of both thermal and magnetic effects. JLab LG-1 that we studied was limited at 40.5 MV/m, corresponding to B peak = 173 mT, in 89 mode. Dual mode measurements on this quench indicate that this quench is not purely magnetic, and so we conclude that this field is not the fundamental limit in SRF cavities

  19. Results of radiofrequency ablation of liver tumors: experience of 134 cases

    Directory of Open Access Journals (Sweden)

    Marcelo Augusto Fontenelle Ribeiro Junior

    2008-12-01

    Full Text Available Objective: To study radiofrequency ablation of primary and metastatic livertumors. Methods: The authors present a series of 134 cases, 63 femalesand 71 males with a mean age of 61.2 years, in whom radiofrequencyablation was used either by laparotomy or percutaneously to treat 203lesions. The group was composed of 51 cases of hepatocellular carcinoma,four cases of cholangiocarcinoma, and cases of hepatic metastases, asfollows: 64 of colorectal cancer, 6 of neuroendocrine tumors, 5 of breastcancer, 1 case of pancreas cancer, 1 of kidney cancer, 1 of endometrialcancer and 1 of leiomyosarcoma. Results: Procedure-associatedmorbidity/mortality was 24.8 and 3.7%, respectively. Recurrence wasobserved in 12.7% within a mean time of 10.5 months. Conclusions:Radiofrequency ablation is a safe procedure and can be used in patientswith impaired hepatic function. For metastatic diseases, it does notreplace surgery but it can be associated with other procedures, such assurgery and transarterial chemoembolization, or after recurrence, leadingto greater probability of remaining disease-free.

  20. Nonsurgical Transurethral Radiofrequency Collagen Denaturation: Results at Three Years after Treatment

    Directory of Open Access Journals (Sweden)

    Denise M. Elser

    2011-01-01

    Full Text Available Objective. To assess treatment efficacy and quality of life in women with stress urinary incontinence 3 years after treatment with nonsurgical transurethral radiofrequency collagen denaturation. Methods. This prospective study included 139 women with stress urinary incontinence due to bladder outlet hypermobility. Radiofrequency collagen denaturation was performed using local anesthesia in an office setting. Assessments included incontinence quality of life (I-QOL and urogenital distress inventory (UDI-6 instruments. Results. In total, 139 women were enrolled and 136 women were treated (mean age, 47 years. At 36 months, intent-to-treat analysis (n=139 revealed significant improvements in quality of life. Mean I-QOL score improved 17 points from baseline (P=.0004, while mean UDI-6 score improved (decreased 19 points (P=.0005. Conclusions. Transurethral collagen denaturation is a low-risk, office-based procedure that results in durable quality-of-life improvements in a significant proportion of women for as long as 3 years.

  1. 3.0 T MR diffusion weighted imaging in the evaluation of radio-frequency ablation of the liver VX2 tumors

    International Nuclear Information System (INIS)

    Liu Yubao; Liang Changhong; Wang Qiushi; Xie Shufei; Yu Yuanxin; Liu Zaiyi; Zhang Zhonglin

    2010-01-01

    Objective: To evaluate 3.0 T MR DWI techniques in detecting the lesions of pre and post-radiofrequency ablation of the rabbit liver VX2 tumors. Methods: Twenty two New Zealand white rabbits were used in this experiment. Twenty tumor fragments were implanted into the livers of 20 rabbits respectively. Two normal rabbits were used as controls for radiofrequency ablation of the normal liver. 3. 0 T MR DWI was performed 14 to 21 days after tumor implantation (mean, 17 days) in the tumor-bearing animals. Radiofrequency ablation was performed in the 18 tumor-bearing animals and in the two healthy animals. 3.0 T MRI and DWI were performed 7 to 10 days after radiofrequency ablation (mean, 8 days). Pathology was obtained immediately after the completion of post radiofrequency ablation MR imaging. The MRI features and ADC values of pre- and post -radiofrequency ablation lesions in the livers with VX2 tumors and normal rabbits were analyzed and correlation was made with histopathologic findings. Analysis of variance repeated measures were performed in analyzing the differences among the ADC values of different tissues with the same b value. Results: All 20 rabbit liver models of VX2 tumors were constructed successfully. One rabbit died of anesthetic overdose, another one showed necrosis within the implanted tumor. All 18 untreated VX2 tumors had predominantly low or iso-signal intensity on T 1 WI and high signal intensity on T 2 WI. All 18 VX2 tumors and 2 normal rabbits were treated by radiofrequency ablation successfully. Lesions treated by Radiofrequency ablation displayed low signal intensity on T 1 WI, and high signal intensity on T 2 WI. Seven to 10 days after radiofrequency ablation, lesions varied from having low signal intensity to slightly increased signal intensity on T 1 WI, with areas of mixed (high, intermediate, and low) signal intensity. A peripheral rim of high signal intensity with varying thickness on T 2 WI correlated with granulation tissue, which

  2. Evaluation of three sample preparation methods for the direct identification of bacteria in positive blood cultures by MALDI-TOF

    OpenAIRE

    Tanner, Hannah; Evans, Jason T.; Gossain, Savita; Hussain, Abid

    2017-01-01

    Background Patient mortality is significantly reduced by rapid identification of bacteria from sterile sites. MALDI-TOF can identify bacteria directly from positive blood cultures and multiple sample preparation methods are available. We evaluated three sample preparation methods and two MALDI-TOF score cut-off values. Positive blood culture bottles with organisms present in Gram stains were prospectively analysed by MALDI-TOF. Three lysis reagents (Saponin, SDS, and SepsiTyper lysis bufer) w...

  3. Scheme to funnel ion beams with a radio-frequency quadrupole

    International Nuclear Information System (INIS)

    Stokes, R.H.; Minerbo, G.N.

    1985-01-01

    We describe a proposed method to funnel ion beams using a new form of the radio-frequency quadrupole (RFQ) structure. This RFQ accepts two bunched ion beams and combines them into a single final beam with interlaced microstructure pulses. It also provides uninterrupted periodic transverse focusing to facilitate the funneling of beams with high current and low emittance

  4. Novel, improved sample preparation for rapid, direct identification from positive blood cultures using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry.

    Science.gov (United States)

    Schubert, Sören; Weinert, Kirsten; Wagner, Chris; Gunzl, Beatrix; Wieser, Andreas; Maier, Thomas; Kostrzewa, Markus

    2011-11-01

    Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is widely used for rapid and reliable identification of bacteria and yeast grown on agar plates. Moreover, MALDI-TOF MS also holds promise for bacterial identification from blood culture (BC) broths in hospital laboratories. The most important technical step for the identification of bacteria from positive BCs by MALDI-TOF MS is sample preparation to remove blood cells and host proteins. We present a method for novel, rapid sample preparation using differential lysis of blood cells. We demonstrate the efficacy and ease of use of this sample preparation and subsequent MALDI-TOF MS identification, applying it to a total of 500 aerobic and anaerobic BCs reported to be positive by a Bactec 9240 system. In 86.5% of all BCs, the microorganism species were correctly identified. Moreover, in 18/27 mixed cultures at least one isolate was correctly identified. A novel method that adjusts the score value for MALDI-TOF MS results is proposed, further improving the proportion of correctly identified samples. The results of the present study show that the MALDI-TOF MS-based method allows rapid (directly from positive BCs and with high accuracy. Copyright © 2011 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  5. Percutaneous radiofrequency ablation of lung metastases from colorectal carcinoma under C-arm cone beam CT guidance.

    Science.gov (United States)

    Amouyal, G; Pernot, S; Déan, C; Cholley, B; Scotté, F; Sapoval, M; Pellerin, O

    2017-11-01

    The aim of this study was to assess the feasibility, safety and efficacy of percutaneous radiofrequency ablation of lung metastases from colorectal carcinoma using C-arm cone beam computed tomography (CBCT) guidance. This single-center prospective observational study was performed from August 2013 to August 2016, and included consecutive patients referred for radiofrequency ablation of lung metastases from colorectal cancer. Radiofrequency ablation procedures were performed under C-arm CBCT guidance. Feasibility was assessed by probe accuracy placement, time to accurate placement and number of C-arm CBCT acquisitions to reach the target lesion. Safety was assessed by the report of adverse event graded using the common terminology criteria for adverse events (CTCAE-V4.0). Efficacy was assessed by metastases response rate using RECIST 1.1 and 18 FDG-PET-CT tumor uptake at 6months. Fifty-four consecutive patients (32 men, 22 women) with a mean age of 63±8 (SD) years (range: 51-81years) with a total of 56 lung metastasis from colorectal metastases were treated in a single session. The mean tumor diameter was 25.6±4.5 (SD)mm (range: 17-31mm). Median time to insert the needle into the target lesion was 10min (range: 5-25min). Median number of needles repositioning and C-arm CBCT acquisition per patient was 1 (range: 0-3) and 4 (range: 3-6) respectively. The accuracy for radiofrequency ablation probe placement was 2±0.2 (SD)mm (range: 0-9mm). Pneumothorax requiring chest tube placement occurred in one patient (CTCAE-V4.0 grade 3). At 6months, all patients were alive with tumor response rate of -27% and had no significant activity on the 18 FDG-PET CT follow-up. Percutaneous radiofrequency ablation of lung metastases from colorectal cancer under C-arm CBCT guidance is feasible and safe, with immediate and short-term results similar to those obtained using conventional CT guidance. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS

  6. Pulsed Radiofrequency in the Treatment of Persistent Pain After Inguinal Herniotomy

    DEFF Research Database (Denmark)

    Werner, Mads U; Bischoff, Joakim Mutahi; Rathmell, James P

    2012-01-01

    . The use of pulsed radiofrequency (PFR), leading to nondestructive lesions of nerve structures, has been proposed as a treatment option. To examine the evidence of treatment efficacy, a systematic literature search was made. From the databases PubMed, Embase, and CINAHL, 4 case reports were retrieved and 8...

  7. From mini-invasive to non-invasive treatment using monopolar radiofrequency: the next orthopaedic frontier.

    Science.gov (United States)

    Whipple, Terry L

    2009-10-01

    Tendinopathy arises from a failed tendon healing process. Current non-invasive therapeutic alternatives are anti-inflammatory in nature, and outcomes are unpredictable. The benefit of invasive alternatives resides in the induction of the healing response. A new technology that uses non-invasive monopolar capacitive coupled radiofrequency has demonstrated the ability to raise temperatures in tendons and ligaments above 50 degrees C, the threshold for collagen modulation, tissue shrinkage and recruitment of macrophages, fibroblasts, and heat shock protein factors, without damaging the overlying structures, resulting in activation of the wound healing response. Monopolar capacitive-coupled radiofrequency offers a new non-invasive choice for tendinopathies and sprained ligaments. It does not interfere with subsequent surgical procedures should they become necessary.

  8. Selective percutaneous radiofrequency thermocoagulation in the treatment of trigeminal neuralgia:report on 1860 cases

    Institute of Scientific and Technical Information of China (English)

    吴承远; 孟凡刚; 徐淑军; 刘玉光; 王宏伟

    2004-01-01

    @@Trigeminal neuralgia (TN) is defined by the International Association for the Study of Pain as "a sudden, usually unilateral, severe, brief, stabbing, recurrent pain in the distribution of one or more branches of the fifth cranial nerve".1 The incidence rate is about three to five cases per year per 100000 persons and increases with age.2 In our hospital, percutaneous radiofrequency therapy was performed on 1860 patients with TN from June 1986 to April 2003, and percutaneous trigeminal ganglion radiofrequency therapy on 579 cases. Among this group of patients, X-ray, 3-D CT, and navigational localization of the oval foramen were performed on 42 cases. The indications, techniques, and results are reported here.

  9. Adaptation of a radiofrequency glow discharge optical emission spectrometer (RF-GD-OES) to the analysis of light elements (carbon, nitrogen, oxygen and hydrogen) in solids: glove box integration for the analysis of nuclear samples

    International Nuclear Information System (INIS)

    Hubinois, J.-C.

    2001-01-01

    The purpose of this work is to use the radiofrequency glow discharge optical emission spectrometry in order to quantitatively determine carbon, nitrogen, oxygen and hydrogen at low concentration (in the ppm range) in nuclear materials. In this study, and before the definitive contamination of the system, works are carried out on non radioactive materials (steel, pure iron, copper and titanium). As the initial apparatus could not deliver a RF power inducing a reproducible discharge and was not adapted to the analysis of light elements: 1- The radiofrequency system had to be changed, 2- The systems controlling gaseous atmospheres had to be improved in order to obtain analytical signals stemming strictly from the sample, 3- Three discharge lamps had to be tested and compared in terms of performances, 4- The system of collection of light had to be optimized. The modifications that were brought to the initial system improved intensities and stabilities of signals which allowed lower detection limits (1000 times lower for carbon). These latter are in the ppm range for carbon and about a few tens of ppm for nitrogen and oxygen in pure irons. Calibration curves were plotted in materials presenting very different sputtering rates in order to check the existence of a 'function of analytical transfer' with the purpose of palliating the lack of reference materials certified in light elements at low concentration. Transposition of this type of function to other matrices remains to be checked. Concerning hydrogen, since no usable reference material with our technique is available, certified materials in deuterium (chosen as a surrogate for hydrogen) were studied in order to exhibit the feasibility the analysis of hydrogen. Parallel to these works, results obtained by modeling a RF discharge show that the performances of the lamp can be improved and that the optical system must be strictly adapted to the glow discharge. (author) [fr

  10. Radiofrequency ablation for unresectable locally advanced pancreatic cancer: a systematic review

    Science.gov (United States)

    Fegrachi, Samira; Besselink, Marc G; van Santvoort, Hjalmar C; van Hillegersberg, Richard; Molenaar, Izaak Quintus

    2014-01-01

    Background: Median survival in patients with unresectable locally advanced pancreatic cancer lies in the range of 9–15 months. Radiofrequency ablation (RFA) may prolong survival, but data on its safety and efficacy are scarce. Methods: A systematic literature search was performed in PubMed, EMBASE and the Cochrane Library with the syntax ‘(radiofrequency OR RFA) AND (pancreas OR pancreatic)’ for studies published until 1 January 2012. In addition, a search of the proceedings of conferences on pancreatic disease that took place during 2009–2011 was performed. Studies with fewer than five patients were excluded as they were considered to be case reports. The primary endpoint was survival. Secondary endpoints included morbidity and mortality. Results: Five studies involving a total of 158 patients with pancreatic cancer treated with RFA fulfilled the eligibility criteria. These studies reported median survival after RFA of 3–33 months, morbidity related to RFA of 4–37%, mortality of 0–19% and overall morbidity of 10–43%. Pooling of data was not appropriate as the study populations and reported outcomes were heterogeneous. Crucial safety aspects included ensuring a maximum RFA tip temperature of < 90 °C and ensuring minimum distances between the RFA probe and surrounding structures. Conclusions: Radiofrequency ablation seems to be feasible and safe when it is used with the correct temperature and at an appropriate distance from vital structures. It appears to have a positive impact on survival. Multicentre randomized trials are necessary to determine the true effect size of RFA and to minimize the impacts of selection and publication biases. PMID:23600801

  11. Radiotelemetry and wildlife: Highlighting a gap in the knowledge on radiofrequency radiation effects

    International Nuclear Information System (INIS)

    Balmori, Alfonso

    2016-01-01

    Radio transmitters and associated devices may induce negative effects that can bias the results of ongoing research. The main documented effects of radio transmitters on animals include reduced survival, decreased productivity, changes in behaviour and movement patterns and a biased sex ratio. The only factors that have claimed responsibility for these possible damages are the weight of the radio transmitter and associated devices, and the attachment type. The electromagnetic radiation produced by radio transmitters has not been considered so far in research. There have been no studies evaluating the effects of non-ionising electromagnetic radiation (radiofrequency signals) necessary for tracking, although the problems found were significantly associated with the length of time that animals had been carrying their radio transmitters. Similar problems as those in radiotracked animals have been found in numerous studies with animals exposed to radiofrequency radiation for a sufficient amount of time. Laboratory scientists investigating the orientation of animals know they have to shield the place where experiments are performed to prevent interference from man-made radiation, as anthropogenic signals may distort the results. It is paradoxical that, at the same time, field scientists investigating the movements and other aspects of animal biology are providing animals with radio transmitters that emit the same type of radiation, since this may affect the results concerning their orientation and movement. This paper identifies gaps in the knowledge that should be investigated in-depth. The possibility that the radiofrequency radiation from radiotracking devices is responsible for the findings should be considered. Considering this factor may allow researchers to best understand the long-term effects found. - Highlights: • Radiotracking may induce negative effects that can bias the results. • Effects have been documented on survival, reproduction and behaviour.

  12. Radiotelemetry and wildlife: Highlighting a gap in the knowledge on radiofrequency radiation effects

    Energy Technology Data Exchange (ETDEWEB)

    Balmori, Alfonso, E-mail: balmaral@jcyl.es

    2016-02-01

    Radio transmitters and associated devices may induce negative effects that can bias the results of ongoing research. The main documented effects of radio transmitters on animals include reduced survival, decreased productivity, changes in behaviour and movement patterns and a biased sex ratio. The only factors that have claimed responsibility for these possible damages are the weight of the radio transmitter and associated devices, and the attachment type. The electromagnetic radiation produced by radio transmitters has not been considered so far in research. There have been no studies evaluating the effects of non-ionising electromagnetic radiation (radiofrequency signals) necessary for tracking, although the problems found were significantly associated with the length of time that animals had been carrying their radio transmitters. Similar problems as those in radiotracked animals have been found in numerous studies with animals exposed to radiofrequency radiation for a sufficient amount of time. Laboratory scientists investigating the orientation of animals know they have to shield the place where experiments are performed to prevent interference from man-made radiation, as anthropogenic signals may distort the results. It is paradoxical that, at the same time, field scientists investigating the movements and other aspects of animal biology are providing animals with radio transmitters that emit the same type of radiation, since this may affect the results concerning their orientation and movement. This paper identifies gaps in the knowledge that should be investigated in-depth. The possibility that the radiofrequency radiation from radiotracking devices is responsible for the findings should be considered. Considering this factor may allow researchers to best understand the long-term effects found. - Highlights: • Radiotracking may induce negative effects that can bias the results. • Effects have been documented on survival, reproduction and behaviour.

  13. Mathematical 3D modelling and sensitivity analysis of multipolar radiofrequency ablation in the spine.

    Science.gov (United States)

    Matschek, Janine; Bullinger, Eric; von Haeseler, Friedrich; Skalej, Martin; Findeisen, Rolf

    2017-02-01

    Radiofrequency ablation is a valuable tool in the treatment of many diseases, especially cancer. However, controlled heating up to apoptosis of the desired target tissue in complex situations, e.g. in the spine, is challenging and requires experienced interventionalists. For such challenging situations a mathematical model of radiofrequency ablation allows to understand, improve and optimise the outcome of the medical therapy. The main contribution of this work is the derivation of a tailored, yet expandable mathematical model, for the simulation, analysis, planning and control of radiofrequency ablation in complex situations. The dynamic model consists of partial differential equations that describe the potential and temperature distribution during intervention. To account for multipolar operation, time-dependent boundary conditions are introduced. Spatially distributed parameters, like tissue conductivity and blood perfusion, allow to describe the complex 3D environment representing diverse involved tissue types in the spine. To identify the key parameters affecting the prediction quality of the model, the influence of the parameters on the temperature distribution is investigated via a sensitivity analysis. Simulations underpin the quality of the derived model and the analysis approach. The proposed modelling and analysis schemes set the basis for intervention planning, state- and parameter estimation, and control. Copyright © 2016. Published by Elsevier Inc.

  14. Bimodal electric tissue ablation (BETA) - in-vivo evaluation of the effect of applying direct current before and during radiofrequency ablation of porcine liver

    International Nuclear Information System (INIS)

    Cockburn, J.F.; Maddern, G.J.; Wemyss-Holden, S.A.

    2007-01-01

    Aim: To examine the effect of applying increasing amounts of direct current (DC) before and during alternating current radiofrequency ablation of porcine liver. Materials and methods: Using a Radiotherapeutics RF3000 generator, a 9 V AC/DC transformer and a 16 G plain aluminium tube as an electrode, a control group of 24 porcine hepatic radiofrequency ablation zones was compared with 24 zones created using a bimodal electric tissue ablation (BETA) technique in three pigs. All ablations were terminated when tissue impedance rose to greater than 999 Ω or radiofrequency energy input fell below 5 W on three successive measurements taken at 1 min intervals. BETA ablations were performed in two phases: an initial phase of variable duration DC followed by a second phase during which standard radiofrequency ablation was applied simultaneously with DC. During this second phase, radiofrequency power input was regulated by the feedback circuitry of the RF3000 generator according to changes in tissue impedance. The diameters (mm) of each ablation zone were measured by two observers in two planes perpendicular to the plane of needle insertion. The mean short axis diameter of each ablation zone was subjected to statistical analysis. Results: With increased duration of prior application of DC, there was a progressive increase in the diameter of the ablation zone (p < 0.001). This effect increased sharply up to 300 s of pre-treatment after which a further increase in diameter occurred, but at a much lesser rate. A maximum ablation zone diameter of 32 mm was produced (control diameters 10-13 mm). Conclusion: Applying a 9 V DC to porcine liver in vivo, and continuing this DC application during subsequent radiofrequency ablation, results in larger ablation zone diameters compared with radiofrequency ablation alone

  15. Bi-modal radiofrequency treatment for coexisting neuralgia and neuropathy in adjacent divisions of the trigeminal nerve.

    Science.gov (United States)

    Bhatjiwale, M; Bhatjiwale, M; Naik, L D; Chopade, P

    2018-05-29

    Trigeminal neuralgia and deafferentation neuropathic pain, or trigeminal neuropathy, are different symptomatologies, rarely reported to present together. The case of a 65-year-old gentleman suffering from trigeminal neuralgia of the maxillary and mandibular division is reported. He first underwent an infraorbital neurectomy that was complicated by deafferentation neuropathic pain, whilst his mandibular neuralgia continued. He was treated successfully for both the neuropathic and neuralgic symptoms in the same session using ultra-extended euthermic pulsed radiofrequency treatment for the maxillary division (V2) and radiofrequency thermocoagulation for the mandibular division (V3). This report is novel in describing the use of dual modalities in the same session for two distinct coexisting clinical entities in two different divisions of the same cranial nerve. The use of ultra-extended pulsed radiofrequency treatment for neuropathic pain in this case is also unique. Nearly 2years after the procedure, the patient continues to have complete pain relief. Copyright © 2018 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  16. Numerical research of a 2D axial symmetry hybrid model for the radio-frequency ion thruster

    Science.gov (United States)

    Chenchen, WU; Xinfeng, SUN; Zuo, GU; Yanhui, JIA

    2018-04-01

    Since the high efficiency discharge is critical to the radio-frequency ion thruster (RIT), a 2D axial symmetry hybrid model has been developed to study the plasma evolution of RIT. The fluid method and the drift energy correction of the electron energy distribution function (EEDF) are applied to the analysis of the RIT discharge. In the meantime, the PIC-MCC method is used to investigate the ion beam current extraction character for the plasma plume region. The beam current simulation results, with the hybrid model, agree well with the experimental results, and the error is lower than 11%, which shows the validity of the model. The further study shows there is an optimal ratio for the radio-frequency (RF) power and the beam current extraction power under the fixed RIT configuration. And the beam extraction efficiency will decrease when the discharge efficiency beyond a certain threshold (about 87 W). As the input parameters of the hybrid model are all the design values, it can be directly used to the optimum design for other kinds of RITs and radio-frequency ion sources.

  17. Manual B-mode versus automated radio-frequency carotid intima-media thickness measurements

    NARCIS (Netherlands)

    Dogan, Soner; Plantinga, Yvonne; Dijk, Joke M.; van der Graaf, Yolanda; Grobbee, Diederick E.; Bots, Michiel L.; Algra, N. N.; Doevendans, P. A.; Eikelboom, C.; van der Graaf, Y.; Grobbee, E.; Kappelle, L. J.; Mali, W. P. Th M.; Moll, F. L.; Rutten, G. E. H. M.; Visseren, F. L. J.

    2009-01-01

    Carotid intima-media thickness (CIMT) serves as an indicator of atherosclerosis and cardiovascular risk. Manual measurements of B-mode ultrasound images are the most applied method. Automated measurements with radiofrequency (RF) ultrasound have been suggested as an alternative. The aim of this

  18. LAPAROSCOPIC NEPHRECTOMY USING RADIOFREQUENCY THERMAL ABLATION

    Directory of Open Access Journals (Sweden)

    B. Ya. Alekseev

    2012-01-01

    Full Text Available The wide use of current diagnostic techniques, such as ultrasound study, computed tomography, and magnetic resonance imaging, has led to significantly increased detection rates for disease in its early stages. This gave rise to a change in the standards for the treatment of locally advanced renal cell carcinoma (RCC. Laparoscopic nephrectomy (LN has recently become the standard treatment of locally advanced RCC in the clinics having much experience with laparoscopic surgery. The chief drawback of LN is difficulties in maintaining intraoperative hemostasis and a need for creating renal tissue ischemia. The paper gives the intermediate results of application of the new procedure of LN using radiofrequency thermal ablation in patients with non-ischemic early-stage RCC.

  19. Optical generation of radio-frequency power

    International Nuclear Information System (INIS)

    Hietala, V.M.; Vawter, G.A.; Brennan, T.M.; Hammons, B.E.; Meyer, W.J.

    1994-11-01

    An optical technique for high-power radio-frequency (RF) signal generation is described. The technique uses a unique photodetector based on a traveling-wave design driven by an appropriately modulated light source. The traveling-wave photodetector (TWPD) exhibits simultaneously a theoretical quantum efficiency approaching 100 % and a very large electrical bandwidth. Additionally, it is capable of dissipating the high-power levels required for the RF generation technique. The modulated light source is formed by either the beating together of two lasers or by the direct modulation of a light source. A system example is given which predicts RF power levels of 100's of mW's at millimeter wave frequencies with a theoretical ''wall-plug'' efficiency approaching 34%

  20. Species-specific identification from incomplete sampling: applying DNA barcodes to monitoring invasive solanum plants.

    Science.gov (United States)

    Zhang, Wei; Fan, Xiaohong; Zhu, Shuifang; Zhao, Hong; Fu, Lianzhong

    2013-01-01

    Comprehensive sampling is crucial to DNA barcoding, but it is rarely performed because materials are usually unavailable. In practice, only a few rather than all species of a genus are required to be identified. Thus identification of a given species using a limited sample is of great importance in current application of DNA barcodes. Here, we selected 70 individuals representing 48 species from each major lineage of Solanum, one of the most species-rich genera of seed plants, to explore whether DNA barcodes can provide reliable specific-species discrimination in the context of incomplete sampling. Chloroplast genes ndhF and trnS-trnG and the nuclear gene waxy, the commonly used markers in Solanum phylogeny, were selected as the supplementary barcodes. The tree-building and modified barcode gap methods were employed to assess species resolution. The results showed that four Solanum species of quarantine concern could be successfully identified through the two-step barcoding sampling strategy. In addition, discrepancies between nuclear and cpDNA barcodes in some samples demonstrated the ability to discriminate hybrid species, and highlights the necessity of using barcode regions with different modes of inheritance. We conclude that efficient phylogenetic markers are good candidates as the supplementary barcodes in a given taxonomic group. Critically, we hypothesized that a specific-species could be identified from a phylogenetic framework using incomplete sampling-through this, DNA barcoding will greatly benefit the current fields of its application.

  1. CT-guided percutaneous radiofrequency denervation of the sacroiliac joint

    Energy Technology Data Exchange (ETDEWEB)

    Gevargez, A.; Schirp, S.; Braun, M. [Department of Radiology and Microtherapy, University of Witten/Herdecke, Bochum (Germany); Groenemeyer, D. [Department of Radiology and Microtherapy, University of Witten/Herdecke, Bochum (Germany); EFMT Development and Research Center for Microtherapy, Bochum (Germany)

    2002-06-01

    Defining the origin of low back pain is a challenging task. Among a variety of factors the sacroiliac joint (SIJ) is a possible pain generator, although precise diagnosis is difficult. Joint blocks may reduce pain, but are, in cases, of only temporary effect. This study was conducted to evaluate CT-guided percutaneous radiofrequency denervation of the sacroiliac joint in patients with low back pain. The procedure was performed on 38 patients who only temporarily responded to CT-guided SIJ blocks. The denervation was carried out in the posterior interosseous sacroiliac ligaments and on the dorsal rami of the fifth spinal nerve. All interventions were carried out under CT guidance as out-patient therapies. Three months after the therapy, 13 patients (34.2%) were completely free of pain. Twelve patients (31.6%) reported on a substantial pain reduction, 7 patients (18.4%) had obtained a slight and 3 patients (7.9%) no pain reduction. The data of 3 patients (7.9%) was missing. There were no intra- or postoperative complications. Computed tomography-guided percutaneous radiofrequency denervation of the sacroiliac joint appears safe and effective. The procedure may be a useful therapeutic modality, especially in patients with chronic low back pain, who only temporarily respond to therapeutic blocks. (orig.)

  2. CT-guided percutaneous radiofrequency denervation of the sacroiliac joint

    International Nuclear Information System (INIS)

    Gevargez, A.; Schirp, S.; Braun, M.; Groenemeyer, D.

    2002-01-01

    Defining the origin of low back pain is a challenging task. Among a variety of factors the sacroiliac joint (SIJ) is a possible pain generator, although precise diagnosis is difficult. Joint blocks may reduce pain, but are, in cases, of only temporary effect. This study was conducted to evaluate CT-guided percutaneous radiofrequency denervation of the sacroiliac joint in patients with low back pain. The procedure was performed on 38 patients who only temporarily responded to CT-guided SIJ blocks. The denervation was carried out in the posterior interosseous sacroiliac ligaments and on the dorsal rami of the fifth spinal nerve. All interventions were carried out under CT guidance as out-patient therapies. Three months after the therapy, 13 patients (34.2%) were completely free of pain. Twelve patients (31.6%) reported on a substantial pain reduction, 7 patients (18.4%) had obtained a slight and 3 patients (7.9%) no pain reduction. The data of 3 patients (7.9%) was missing. There were no intra- or postoperative complications. Computed tomography-guided percutaneous radiofrequency denervation of the sacroiliac joint appears safe and effective. The procedure may be a useful therapeutic modality, especially in patients with chronic low back pain, who only temporarily respond to therapeutic blocks. (orig.)

  3. Radiofrequency fields in our surroundings; Radiofrekvente felt i vaare omgivelser

    Energy Technology Data Exchange (ETDEWEB)

    2011-07-01

    In 2010, the National Radiation Protection Authority (NRPA) with the Post and Telecommunications Authority carried out a project where it is measured radiofrequency fields from various telecom systems in homes, kindergartens, schools, offices, and urban environments. Close to 99 percent of the measurement points were found values of less than one thousandth of the maximum. No values were near the limits. (AG)

  4. Radiofrequency ablation of pancreas and optimal cooling of peripancreatic tissue in an ex-vivo porcine model

    Directory of Open Access Journals (Sweden)

    Michal Crha

    2011-01-01

    Full Text Available Radiofrequency ablation is a possible palliative treatment for patients suffering from pancreatic neoplasia. However, radiofrequency-induced damage to the peripancreatic tissues during pancreatic ablation might cause fatal complications. The aim of this experimental ex vivo study on pigs was to verify ablation protocols and evaluate whether or not the cooling of peripancereatic tissues during pancreatic ablation has any benefit for their protection against thermal injury. Radiofrequency ablation was performed on 52 pancreatic specimens obtained from pigs. During each pancreatic ablation, continuous measurements of the temperature in the portal vein and duodenal lumen were performed. Peripancreatic tissues were either not cooled or were cooled by being submerged in 14 °C water, or by a perfusion of the portal vein and duodenum with 14 °C saline. The effects of variation in target temperature of the ablated area (90 °C and 100 °C, duration of ablation (5 and 10 min and the effect of peripancreatic tissues cooling were studied. We proved that optimal radiofrequency ablation of the porcine pancreas can be reached with the temperature of 90  °C for 5 min in the ablated area. The perfusion of the duodenal and portal vein by 14 °C saline was found to be the most effective cooling method for minimizing damage to the walls. Continuous measurement of temperatures in peripancreatic tissues will provide useful feedback to assist in their protection against thermal injury. This therapy could be used in the treatment of pancreatic tumours.

  5. Evaluation of ferromagnetic fluids and suspensions for the site-specific radiofrequency-induced hyperthermia of MX11 sarcoma cells in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Brusentsov, Nikolai A.; Gogosov, V.V.; Brusentsova, T.N.; Sergeev, A.V.; Jurchenko, N.Y.; Kuznetsov, Anatoly A.; Kuznetsov, Oleg A. E-mail: oleg@louisiana.edu; Shumakov, L.I

    2001-07-01

    Seventeen different ferromagnetic fluids and suspensions were prepared and evaluated for application in radiofrequency-induced hyperthermia. Specific power absorption rates were measured at 0.88 MHz to range from 0 to 240 W per gram of iron for different preparations. Survival of MX11 cells mixed with ferrofluids and subjected to radiofrequency was much lower than with RF without ferrofluid or ferrofluid alone.

  6. Evaluation of ferromagnetic fluids and suspensions for the site-specific radiofrequency-induced hyperthermia of MX11 sarcoma cells in vitro

    International Nuclear Information System (INIS)

    Brusentsov, Nikolai A.; Gogosov, V.V.; Brusentsova, T.N.; Sergeev, A.V.; Jurchenko, N.Y.; Kuznetsov, Anatoly A.; Kuznetsov, Oleg A.; Shumakov, L.I.

    2001-01-01

    Seventeen different ferromagnetic fluids and suspensions were prepared and evaluated for application in radiofrequency-induced hyperthermia. Specific power absorption rates were measured at 0.88 MHz to range from 0 to 240 W per gram of iron for different preparations. Survival of MX11 cells mixed with ferrofluids and subjected to radiofrequency was much lower than with RF without ferrofluid or ferrofluid alone

  7. Identification of alcohol and cocaine derivatives in pregnacy in meconium samples.

    Directory of Open Access Journals (Sweden)

    Mario Moraes Castro

    2014-12-01

    The investigation consisted on an observational analytic cross-sectional study of 240 puerperal women and their children born at the Hospital Pereira Rossell from November 2010 to March 2011. The method used for the identification of free fatty acid ethyl esters in meconium of newborns was developed at the Polo Tecnológico de Pando, Facultad de Química, Universidad de la República for this investigation. The media of maternal age was 25; Alcohol consumption during pregnancy was admitted by 81 women, and the presence of free fatty acids ethyl esters was confirmed in 113 cases (49.78%; the consumption of cocaine hydrochloride and freebase cocaine was positive in 9.25% cases. Alcohol consumption was identified in half of pregnant women. The consumption of cocaine derivatives in the population studied was high. Exposed fetus can be identified with the analysis of meconium samples, with more certainty than by reports of patients.

  8. Effects of GSM modulated radio-frequency electromagnetic radiation on permeability of blood-brain barrier in male & female rats.

    Science.gov (United States)

    Sırav, Bahriye; Seyhan, Nesrin

    2016-09-01

    With the increased use of mobile phones, their biological and health effects have become more important. Usage of mobile phones near the head increases the possibility of effects on brain tissue. This study was designed to investigate the possible effects of pulse modulated 900MHz and 1800MHz radio-frequency radiation on the permeability of blood-brain barrier of rats. Study was performed with 6 groups of young adult male and female wistar albino rats. The permeability of blood-brain barrier to intravenously injected evans blue dye was quantitatively examined for both control and radio-frequency radiarion exposed groups. For male groups; Evans blue content in the whole brain was found to be 0.08±0.01mg% in the control, 0.13±0.03mg% in 900MHz exposed and 0.26±0.05mg% in 1800MHz exposed animals. In both male radio-frequency radiation exposed groups, the permeability of blood-brain barrier found to be increased with respect to the controls (pradiation exposure was found more effective on the male animals (p0.01). However 900MHz pulse modulated radio-frequency exposure was found effective on the permeability of blood-brain barrier of female animals. Results have shown that 20min pulse modulated radio-frequency radiation exposure of 900MHz and 1800MHz induces an effect and increases the permeability of blood-brain barrier of male rats. For females, 900MHz was found effective and it could be concluded that this result may due to the physiological differences between female and male animals. The results of this study suggest that mobile phone radation could lead to increase the permeability of blood-brain barrier under non-thermal exposure levels. More studies are needed to demonstrate the mechanisms of that breakdown. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Measurement uncertainty in broadband radiofrequency radiation level measurements

    Directory of Open Access Journals (Sweden)

    Vulević Branislav D.

    2014-01-01

    Full Text Available For the evaluation of measurement uncertainty in the measurement of broadband radio frequency radiation, in this paper we propose a new approach based on the experience of the authors of the paper with measurements of radiofrequency electric field levels conducted in residential areas of Belgrade and over 35 municipalities in Serbia. The main objective of the paper is to present practical solutions in the evaluation of broadband measurement uncertainty for the in-situ RF radiation levels. [Projekat Ministarstva nauke Republike Srbije, br. III43009

  10. Loop radiofrequency coils for clinical magnetic resonance imaging at 7 tesla

    NARCIS (Netherlands)

    Kraff, O.

    2011-01-01

    To date, the 7 T magnetic resonance imaging (MRI) scanner remains a pure research system and there is still a long way ahead till full clinical integration. Key challenges are the absence of a body transmit radiofrequency (RF) coil as well as of dedicated RF coils in general, short RF wavelengths of

  11. Diagrams of ion stability in radio-frequency mass spectrometry

    International Nuclear Information System (INIS)

    Sudakov, M.Yu.

    1994-01-01

    For solving radio-frequency mass spectrometry problems and dynamic ion containment are studied and systematized different ways for constructing the ion stability diagrams. A new universal set of parameters is proposed for diagram construction-angular variables, which are the phase raid of ion oscillational motion during positive and negative values of the supplying voltage. An effective analytical method is proposed for optimization of the parameters of the pulsed supplying voltage, in particular its repetition rate

  12. Thermal Ablation for Benign Thyroid Nodules: Radiofrequency and Laser

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jung Hwan; Lee, Jeong Hyun [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Valcavi, Roberto [Endocrinology Division and Thyroid Disease Center, Arcispedale Santa Maria Nuova, Reggio Emilia (Italy); Pacella, Claudio M. [Diagnostic Imaging and Interventional Radiology Department, Ospedale Regina Apostolorum, Albano Laziale-Rome (IT); Rhim, Hyun Chul [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Na, Dong Kyu [Human Medical Imaging and Intervention Center, Seoul (Korea, Republic of)

    2011-10-15

    Although ethanol ablation has been successfully used to treat cystic thyroid nodules, this procedure is less effective when the thyroid nodules are solid. Radiofrequency (RF) ablation, a newer procedure used to treat malignant liver tumors, has been valuable in the treatment of benign thyroid nodules regardless of the extent of the solid component. This article reviews the basic physics, techniques, applications, results, and complications of thyroid RF ablation, in comparison to laser ablation.

  13. Novel, Improved Sample Preparation for Rapid, Direct Identification from Positive Blood Cultures Using Matrix-Assisted Laser Desorption/Ionization Time-of-Flight (MALDI-TOF) Mass Spectrometry

    OpenAIRE

    Schubert, Sören; Weinert, Kirsten; Wagner, Chris; Gunzl, Beatrix; Wieser, Andreas; Maier, Thomas; Kostrzewa, Markus

    2011-01-01

    Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is widely used for rapid and reliable identification of bacteria and yeast grown on agar plates. Moreover, MALDI-TOF MS also holds promise for bacterial identification from blood culture (BC) broths in hospital laboratories. The most important technical step for the identification of bacteria from positive BCs by MALDI-TOF MS is sample preparation to remove blood cells and host proteins. We present a m...

  14. Ablation of hypertrophic septum using radiofrequency energy: an alternative for gradient reduction in patient with hypertrophic obstructive cardiomyopathy?

    Science.gov (United States)

    Riedlbauchová, Lucie; Janoušek, Jan; Veselka, Josef

    2013-06-01

    Alcohol septal ablation and surgical myectomy represent accepted therapeutic options for treatment of symptomatic patients with hypertrophic obstructive cardiomyopathy. Long-term experience with radiofrequency ablation of arrhythmogenic substrates raised a question if this technique might be effective for left ventricular outflow tract (LVOT) gradient reduction. We report on a 63-year-old patient with recurrence of symptoms 1 year after alcohol septal ablation (ASA) leading originally to a significant reduction of both symptoms and gradient. Due to a new increase of gradient in the LVOT up to 200 mm Hg with corresponding worsening of symptoms and due to refusal of surgical myectomy by the patient, endocardial radiofrequency ablation of the septal hypertrophy (ERASH) was indicated. Radiofrequency ablation was performed in the LVOT using irrigated-tip ablation catheter; the target site was identified using intracardiac echocardiography and electroanatomical CARTO mapping. ERASH caused an immediate gradient reduction due to hypokinesis of the ablated septum. At 2-month follow-up exam, significant clinical improvement was observed, together with persistent gradient reduction assessed with Doppler echocardiography. Echocardiography and magnetic resonance revealed persistent septal hypokinesis and slight thinning of the ablated region. Septal ablation using radiofrequency energy may be a promising alternative or adjunct to the treatment of hypertrophic obstructive cardiomyopathy. Intracardiac echocardiography and electroanatomical CARTO mapping enable exact lesion placement and preservation of atrioventricular conduction.

  15. Detailed investigation of optoelectronic and microstructural properties of plasma polymerized cyclohexane thin films: Dependence on the radiofrequency power

    International Nuclear Information System (INIS)

    Manaa, C.; Bouaziz, L.; Lejeune, M.; Zellama, K.; Benlahsen, M.; Kouki, F.; Mejatty, M.; Bouchriha, H.

    2015-01-01

    Optical properties of polymerized cyclohexane films deposited by radiofrequency plasma enhanced chemical vapor deposition technique at different radiofrequency powers onto glass and silicon substrates, are studied and correlated with the microstructure of the films, using a combination of atomic force microscopy, Raman and Fourier Transformer Infrared spectroscopy and optical measurements. The optical constants such as refractive index n, dielectric permittivity ε and extinction k and absorption α coefficients, are extracted from transmission and reflection spectra through the commercial software CODE. These constants lead, by using common theoretical models as Cauchy, Lorentz, Tauc and single effective oscillator, to the determination of the static refractive index n s and permittivity ε s , the plasma frequency ω p , the carrier density to effective mass ratio N/m e * , the optical conductivity σ oc , the optical band gap E g and the oscillation and dispersion energies E 0 and E d , respectively. We find that n, ε s , ω p , N/m e * , E d , increase with radiofrequency power, while E g and E 0 decrease in the same range of power. These results are well correlated with those obtained from atomic force microscopy, Raman and infrared measurements. They also indicate that the increase of the radiofrequency power promotes the fragmentation of the precursor and increases the carbon C-sp 2 hybridization proportion, which results in an improvement of the optoelectronic properties of the films

  16. Comparison of wet radiofrequency ablation with dry radiofrequency ablation and radiofrequency ablation using hypertonic saline preinjection: ex vivo bovine liver

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Han, Joon Koo; Kim, Se Hyung; Lee, Jae Young; Park, Hee Sun; Hur, Hurn; Choi, Byung Ihn; Shin, Kyung Sook

    2004-01-01

    We wished to compare the in-vitro efficiency of wet radiofrequency (RF) ablation with the efficiency of dry RF ablation and RF ablation with preinjection of NaCl solutions using excised bovine liver. Radiofrequency was applied to excised bovine livers in a monopolar mode for 10 minutes using a 200 W generator and a perfused-cooled electrode with or without injection or slow infusion of NaCl solutions. After placing the perfused-cooled electrode in the explanted liver, 50 ablation zones were created with five different regimens: group A; standard dry RF ablation, group B; RF ablation with 11 mL of 5% NaCl solution preinjection, group C; RF ablation with infusion of 11 mL of 5% NaCl solution at a rate of 1 mL/min, group D; RFA with 6 mL of 36% NaCl solution preinjection, group E; RF ablation with infusion of 6 mL of 36% NaCl solution at a rate of 0.5 mL/min. In groups C and E, infusion of the NaCl solutions was started 1 min before RF ablation and then maintained during RF ablation (wet RF ablation). During RF ablation, we measured the tissue temperature at 15 mm from the electrode. The dimensions of the ablation zones and changes in impedance, current and liver temperature during RF ablation were then compared between the groups. With injection or infusion of NaCl solutions, the mean initial tissue impedance prior to RF ablation was significantly less in groups B, C, D, and E (43-75 Ω) than for group A (80 Ω) (ρ 3 in group A; 12.4 ± 3.8 cm 3 in group B; 80.9 ± 9.9 cm 3 in group C; 45.3 ± 11.3 cm 3 in group D and 81.6 ± 8.6 cm 3 in group E. The tissue temperature measured at 15 mm from the electrode was higher in groups C, D and E than other groups (ρ < 0.05): 53 ± 12 .deg. C in group A, 42 ± 2 .deg. C in group B, 93 ± 8 .deg. C in group C; 79 ± 12 .deg. C in group D and 83 ± 8 .deg.C in group E. Wet RF ablation with 5% or 36% NaCl solutions shows better efficiency in creating a large ablation zone than does dry RF ablation or RF ablation with

  17. DNA-based species identification for faecal samples: An application ...

    African Journals Online (AJOL)

    ... An application on the mammalian survey in Mountain Huangshan Scenic Spot. ... Noninvasive methods using genetic markers have been suggested as ways to ... molecular identification are the useful supplements for traditional field survey.

  18. Use of radiofrequency in cosmetic dermatology: focus on nonablative treatment of acne scars

    Directory of Open Access Journals (Sweden)

    Simmons BJ

    2014-12-01

    Full Text Available Brian J Simmons, Robert D Griffith, Leyre A Falto-Aizpurua, Keyvan Nouri Department of Dermatology and Cutaneous Surgery, University of Miami Miller School of Medicine, University of Miami, Miami, FL, USA Abstract: Acne is a common affliction among many teens and some adults that usually resolves over time. However, the severe sequela of acne scarring can lead to long-term psychological and psychiatric problems. There exists a multitude of modalities to treat acne scars such as more invasive surgical techniques, subcision, chemical peels, ablative lasers, fractional lasers, etc. A more recent technique for the treatment of acne scars is nonablative radiofrequency (RF that works by passing a current through the dermis at a preset depth to produce small thermal wounds in the dermis which, in turn, stimulates dermal remodeling to produce new collagen and soften scar defects. This review article demonstrates that out of all RF modalities, microneedle bipolar RF and fractional bipolar RF treatments offers the best results for acne scarring. An improvement of 25%–75% can be expected after three to four treatment sessions using one to two passes per session. Treatment results are optimal approximately 3 months after final treatment. Common side effects can include transient pain, erythema, and scabbing. Further studies are needed to determine what RF treatment modalities work best for specific scar subtypes, so that further optimization of RF treatments for acne scars can be determined. Keywords: acne scarring, radiofrequency treatments, nonablative radiofrequency treatments, scars

  19. Effect of the Size of the Left Atrium on Sustained Sinus Rhythm in Patients Undergoing Mitral Valve Surgery and Concomitant Bipolar Radiofrequency Ablation for Atrial Fibrillation.

    Science.gov (United States)

    Avdagić, Harun; Sijerčić Avdagić, Selma; Pirić Avdagić, Melika; Antonič, Miha

    2017-12-01

    Atrial fibrillation is associated with systemic embolization and complications due to anticoagulant therapy. Radiofrequency ablation has been established as an effective and safe method for the treatment of atrial fibrillation. The aim of this study was to evaluate the effect of the size of the left atrium on the outcome of surgical radiofrequency ablation. Forty patients scheduled for elective mitral valve surgery and radiofrequency ablation were enrolled in the study. Group 1 consisted of patients with a left atrium diameter ≤5 cm and group 2 of patients with left atrium diameter >5 cm. The primary endpoint of the study was stable sinus rhythm 6 months postoperatively. At 6 months postoperatively, sinus rhythm was present in significantly more group 1 patients as compared with group 2 patients, i.e. 15 (75%) vs. 8 (40%), p=0.025. Multivariate analysis proved the size of the left atrium to be an independent predictor of the radiofrequency ablation outcome. Accordingly, the size of the left atrium was demonstrated to be an important predictor of the outcome of radiofrequency ablation for atrial fibrillation. A lower cut-off value of surgical reduction of the atria than previously reported should be considered in order to improve the radiofrequency ablation outcome.

  20. A touch probe method of operating an implantable RFID tag for orthopedic implant identification.

    Science.gov (United States)

    Liu, Xiaoyu; Berger, J Lee; Ogirala, Ajay; Mickle, Marlin H

    2013-06-01

    The major problem in operating an implantable radio-frequency identification (RFID) tag embedded on an orthopedic implant is low efficiency because of metallic interference. To improve the efficiency, this paper proposes a method of operating an implantable passive RFID tag using a touch probe at 13.56 MHz. This technology relies on the electric field interaction between two pairs of electrodes, one being a part of the touch probe placed on the surface of tissue and the other being a part of the tag installed under the tissue. Compared with using a conventional RFID antenna such as a loop antenna, this method has a better performance in the near field operation range to reduce interference with the orthopedic implant. Properly matching the touch probe and the tag to the tissue and the implant reduces signal attenuation and increases the overall system efficiency. The experiments have shown that this method has a great performance in the near field transcutaneous operation and can be used for orthopedic implant identification.

  1. Radiofrequency ablation vs. surgery for perivascular hepatocellular carcinoma: Propensity score analyses of long-term outcomes.

    Science.gov (United States)

    Lee, Sunyoung; Kang, Tae Wook; Cha, Dong Ik; Song, Kyoung Doo; Lee, Min Woo; Rhim, Hyunchul; Lim, Hyo Keun; Sinn, Dong Hyun; Kim, Jong Man; Kim, Kyunga

    2018-07-01

    The therapeutic outcomes of surgical resection (SR) or radiofrequency ablation (RFA) for perivascular hepatocellular carcinoma (HCC) have not been compared. The aim of this study was to compare SR with RFA as first-line treatment in patients with perivascular HCC and to evaluate the long-term outcomes of both therapies. This retrospective study was approved by the institutional review board. The requirement for informed consent was waived. Between January 2006 and December 2010, a total of 283 consecutive patients with small perivascular HCCs (≤3 cm, Barcelona Clinic Liver Cancer stage 0 or A) underwent SR (n = 182) or RFA (n = 101) as a first-line treatment. The progression-free survival (PFS) and overall survival (OS) rates were compared by propensity score matching. Subgroup analysis of these outcomes was conducted according to the type of hepatic vessels. The median follow-up was 7.8 years. Matching yielded 62 pairs of patients. In the two matched groups, the PFS rates at 5 and 10 years were 58.0% and 17.8%, respectively, in the SR group, and 25.4% and 14.1%, respectively, in the RFA group (p radiofrequency ablation are both treatment options for perivascular hepatocellular carcinoma. We compared outcomes in patients treated with either method. Surgical resection provided better long-term tumor control and overall survival than radiofrequency ablation for patients with a small perivascular hepatocellular carcinoma (≤3 cm) as a first-line treatment, particularly for periportal tumors. The location of the tumor and the type of peritumoral hepatic vessels need to be considered when choosing between surgical resection and radiofrequency ablation for small HCCs. Copyright © 2018 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  2. Towards a compact and precise sample holder for macromolecular crystallography.

    Science.gov (United States)

    Papp, Gergely; Rossi, Christopher; Janocha, Robert; Sorez, Clement; Lopez-Marrero, Marcos; Astruc, Anthony; McCarthy, Andrew; Belrhali, Hassan; Bowler, Matthew W; Cipriani, Florent

    2017-10-01

    Most of the sample holders currently used in macromolecular crystallography offer limited storage density and poor initial crystal-positioning precision upon mounting on a goniometer. This has now become a limiting factor at high-throughput beamlines, where data collection can be performed in a matter of seconds. Furthermore, this lack of precision limits the potential benefits emerging from automated harvesting systems that could provide crystal-position information which would further enhance alignment at beamlines. This situation provided the motivation for the development of a compact and precise sample holder with corresponding pucks, handling tools and robotic transfer protocols. The development process included four main phases: design, prototype manufacture, testing with a robotic sample changer and validation under real conditions on a beamline. Two sample-holder designs are proposed: NewPin and miniSPINE. They share the same robot gripper and allow the storage of 36 sample holders in uni-puck footprint-style pucks, which represents 252 samples in a dry-shipping dewar commonly used in the field. The pucks are identified with human- and machine-readable codes, as well as with radio-frequency identification (RFID) tags. NewPin offers a crystal-repositioning precision of up to 10 µm but requires a specific goniometer socket. The storage density could reach 64 samples using a special puck designed for fully robotic handling. miniSPINE is less precise but uses a goniometer mount compatible with the current SPINE standard. miniSPINE is proposed for the first implementation of the new standard, since it is easier to integrate at beamlines. An upgraded version of the SPINE sample holder with a corresponding puck named SPINEplus is also proposed in order to offer a homogenous and interoperable system. The project involved several European synchrotrons and industrial companies in the fields of consumables and sample-changer robotics. Manual handling of mini

  3. Use of radiofrequency ablation in benign thyroid nodules: a literature review and updates.

    Science.gov (United States)

    Wong, Kai-Pun; Lang, Brian Hung-Hin

    2013-01-01

    Successful thermal ablation using radiofrequency has been reported in various tumors including liver or kidney tumors. Nonsurgical minimally invasive ablative therapy such as radiofrequency ablation (RFA) has been reported to be a safe and efficient treatment option in managing symptomatic cold thyroid nodules or hyperfunctioning thyroid nodules. Pressure and cosmetic symptoms have been shown to be significantly improved both in the short and long terms after RFA. For hyperfunctioning thyroid nodules, RFA is indicated for whom surgery or radioiodine are not indicated or ineffective or for those who refuse surgery or radio-iodine. Improvement of thyroid function with decreased need for antithyroid medications has been reported. Complication rate is relatively low. By reviewing the current literature, we reported its efficacy and complications and compared the efficacy of RFA relative to other ablative options such as ethanol ablation and laser ablation.

  4. Use of Radiofrequency Ablation in Benign Thyroid Nodules: A Literature Review and Updates

    Directory of Open Access Journals (Sweden)

    Kai-Pun Wong

    2013-01-01

    Full Text Available Successful thermal ablation using radiofrequency has been reported in various tumors including liver or kidney tumors. Nonsurgical minimally invasive ablative therapy such as radiofrequency ablation (RFA has been reported to be a safe and efficient treatment option in managing symptomatic cold thyroid nodules or hyperfunctioning thyroid nodules. Pressure and cosmetic symptoms have been shown to be significantly improved both in the short and long terms after RFA. For hyperfunctioning thyroid nodules, RFA is indicated for whom surgery or radioiodine are not indicated or ineffective or for those who refuse surgery or radio-iodine. Improvement of thyroid function with decreased need for antithyroid medications has been reported. Complication rate is relatively low. By reviewing the current literature, we reported its efficacy and complications and compared the efficacy of RFA relative to other ablative options such as ethanol ablation and laser ablation.

  5. Measuring changes of radio-frequency dielectric properties of chicken meat during storage

    Science.gov (United States)

    Changes in dielectric properties of stored chicken meat were tracked by using a radio-frequency dielectric spectroscopy method. For this purpose, the dielectric properties were measured with an open-ended coaxial-line probe and vector network analyzer over a broad frequency range from 200 MHz to 20...

  6. Novel Percutaneous Radiofrequency Ablation of Portal Vein Tumor Thrombus: Safety and Feasibility

    Energy Technology Data Exchange (ETDEWEB)

    Mizandari, Malkhaz [High Technology Medical Center, Tbilisi State Medical University (Georgia); Ao, Guokun [The 309 Hospital of People' s Liberation Army, Department on Oncology (China); Zhang Yaojun; Feng Xi [Imperial College London, Department of Surgery and Cancer (United Kingdom); Shen Qiang [The First Minimally Invasive Department of Eastern Hepatobiliary Surgery Hospital (China); Chen Minshan [Cancer Centre of Sun Yat-Sen University, Department of Hepatobiliary Surgery (China); Lau, Wan Yee [Chinese University of Hong Kong, Department of Surgery, Faculty of Medicine (Hong Kong); Nicholls, Joanna; Jiao Long; Habib, Nagy, E-mail: nagy.habib@imperial.ac.uk [Imperial College London, Department of Surgery and Cancer (United Kingdom)

    2013-02-15

    We report our experience of the safety of partial recanalization of the portal vein using a novel endovascular radiofrequency (RF) catheter for portal vein tumor thrombosis. Six patients with liver cancer and tumor thrombus in the portal vein underwent percutaneous intravascular radiofrequency ablation (RFA) using an endovascular bipolar RF device. A 0.035-inch guidewire was introduced into a tributary of the portal vein and through which a 5G guide catheter was introduced into the main portal vein. After manipulation of the guide catheter over the thrombus under digital subtraction angiography, the endovascular RF device was inserted and activated around the thrombus. There were no observed technique specific complications, such as hemorrhage, vessel perforation, or infection. Post-RFA portography showed partial recanalization of portal vein. RFA of portal vein tumor thrombus in patients with hepatocellular carcinoma is technically feasible and warrants further investigation to assess efficacy compared with current recanalization techniques.

  7. Radiofrequency ablation of accessory pathways in patients with the Wolff-Parkinson-White syndrome: the long-term mortality and risk of atrial fibrillation.

    Science.gov (United States)

    Borregaard, Rune; Lukac, Peter; Gerdes, Christian; Møller, Dorthe; Mortensen, Peter Thomas; Pedersen, Lars; Nielsen, Jens Cosedis; Jensen, Henrik Kjærulf

    2015-01-01

    To assess the long-term mortality and occurrence of post-ablation atrial fibrillation in patients undergoing a radiofrequency ablation for the Wolff-Parkinson-White (WPW) syndrome. A retrospective cohort study of patients (N = 362) subjected to radiofrequency ablation of the WPW syndrome at Aarhus University Hospital from 1990 to 2011. A comparison cohort (N = 3619) was generated from the Danish National Board of Health Central Population Registry. We found no significant difference in all-cause mortality when comparing the WPW group with the control group [hazard ratio (HR): 0.77 and confidence interval (CI): 0.47-1.25]. After radiofrequency ablation, the WPW group had a significantly higher risk of atrial fibrillation than the control group (HR: 4.77 and CI: 3.05-7.43). Atrial fibrillation prior to ablation (HR: 4.66 and CI: 2.09-10.41) and age over 50 years (HR: 9.79 and CI: 4.29-22.36) at the time of ablation were independent risk factors for post-ablation atrial fibrillation in the WPW group. Patients with radiofrequency ablation-treated WPW syndrome have a post-ablation mortality that is similar to the background population. The risk of atrial fibrillation remains high after radiofrequency ablation of the WPW syndrome. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  8. The development of a new analytical model for the identification of saccharide binders in paint samples.

    Science.gov (United States)

    Lluveras-Tenorio, Anna; Mazurek, Joy; Restivo, Annalaura; Colombini, Maria Perla; Bonaduce, Ilaria

    2012-01-01

    This paper describes a method for reliably identifying saccharide materials in paintings. Since the 3(rd) millennium B.C., polysaccharide materials such as plant gums, sugar, flour, and honey were used as binding media and sizing agents in paintings, illuminated manuscripts, and polychrome objects. Although it has been reported that plant gums have a stable composition, their identification in paint samples is often doubtful and rarely discussed. Our research was carried out independently at two different laboratories: the Getty Conservation Institute in Los Angeles, USA (GCI) and the Department of Chemistry and Industrial Chemistry of the University of Pisa, Italy (DCCI). It was shown in a previous stage of this research that the two methods give highly comparable data when analysing both reference paint samples and paint layers from art objects, thus the combined data was used to build a large database. In this study, the simultaneous presence of proteinaceous binders and pigments in fresh and artificially aged paint replicas was investigated, and it highlighted how these can affect the sugar profile of arabic, tragacanth, and fruit tree gums. The environmental contamination due to sugars from various plant tissues is also discussed. The results allowed the development of a new model for the reliable identification of saccharide binders in paintings based on the evaluation of markers that are stable to ageing and unaffected by pigments. This new model was applied to the sugar profiles obtained from the analysis of a large number of samples from murals, easel paintings, manuscripts, and polychrome objects from different geographical areas and dating from the 13(th) century BC to the 20(th) century AD, thus demonstrating its reliability.

  9. The development of a new analytical model for the identification of saccharide binders in paint samples.

    Directory of Open Access Journals (Sweden)

    Anna Lluveras-Tenorio

    Full Text Available This paper describes a method for reliably identifying saccharide materials in paintings. Since the 3(rd millennium B.C., polysaccharide materials such as plant gums, sugar, flour, and honey were used as binding media and sizing agents in paintings, illuminated manuscripts, and polychrome objects. Although it has been reported that plant gums have a stable composition, their identification in paint samples is often doubtful and rarely discussed. Our research was carried out independently at two different laboratories: the Getty Conservation Institute in Los Angeles, USA (GCI and the Department of Chemistry and Industrial Chemistry of the University of Pisa, Italy (DCCI. It was shown in a previous stage of this research that the two methods give highly comparable data when analysing both reference paint samples and paint layers from art objects, thus the combined data was used to build a large database. In this study, the simultaneous presence of proteinaceous binders and pigments in fresh and artificially aged paint replicas was investigated, and it highlighted how these can affect the sugar profile of arabic, tragacanth, and fruit tree gums. The environmental contamination due to sugars from various plant tissues is also discussed. The results allowed the development of a new model for the reliable identification of saccharide binders in paintings based on the evaluation of markers that are stable to ageing and unaffected by pigments. This new model was applied to the sugar profiles obtained from the analysis of a large number of samples from murals, easel paintings, manuscripts, and polychrome objects from different geographical areas and dating from the 13(th century BC to the 20(th century AD, thus demonstrating its reliability.

  10. The Development of a New Analytical Model for the Identification of Saccharide Binders in Paint Samples

    Science.gov (United States)

    Restivo, Annalaura; Colombini, Maria Perla; Bonaduce, Ilaria

    2012-01-01

    This paper describes a method for reliably identifying saccharide materials in paintings. Since the 3rd millennium B.C., polysaccharide materials such as plant gums, sugar, flour, and honey were used as binding media and sizing agents in paintings, illuminated manuscripts, and polychrome objects. Although it has been reported that plant gums have a stable composition, their identification in paint samples is often doubtful and rarely discussed. Our research was carried out independently at two different laboratories: the Getty Conservation Institute in Los Angeles, USA (GCI) and the Department of Chemistry and Industrial Chemistry of the University of Pisa, Italy (DCCI). It was shown in a previous stage of this research that the two methods give highly comparable data when analysing both reference paint samples and paint layers from art objects, thus the combined data was used to build a large database. In this study, the simultaneous presence of proteinaceous binders and pigments in fresh and artificially aged paint replicas was investigated, and it highlighted how these can affect the sugar profile of arabic, tragacanth, and fruit tree gums. The environmental contamination due to sugars from various plant tissues is also discussed. The results allowed the development of a new model for the reliable identification of saccharide binders in paintings based on the evaluation of markers that are stable to ageing and unaffected by pigments. This new model was applied to the sugar profiles obtained from the analysis of a large number of samples from murals, easel paintings, manuscripts, and polychrome objects from different geographical areas and dating from the 13th century BC to the 20th century AD, thus demonstrating its reliability. PMID:23166654

  11. Radiofrequency radiation injures trees around mobile phone base stations.

    Science.gov (United States)

    Waldmann-Selsam, Cornelia; Balmori-de la Puente, Alfonso; Breunig, Helmut; Balmori, Alfonso

    2016-12-01

    In the last two decades, the deployment of phone masts around the world has taken place and, for many years, there has been a discussion in the scientific community about the possible environmental impact from mobile phone base stations. Trees have several advantages over animals as experimental subjects and the aim of this study was to verify whether there is a connection between unusual (generally unilateral) tree damage and radiofrequency exposure. To achieve this, a detailed long-term (2006-2015) field monitoring study was performed in the cities of Bamberg and Hallstadt (Germany). During monitoring, observations and photographic recordings of unusual or unexplainable tree damage were taken, alongside the measurement of electromagnetic radiation. In 2015 measurements of RF-EMF (Radiofrequency Electromagnetic Fields) were carried out. A polygon spanning both cities was chosen as the study site, where 144 measurements of the radiofrequency of electromagnetic fields were taken at a height of 1.5m in streets and parks at different locations. By interpolation of the 144 measurement points, we were able to compile an electromagnetic map of the power flux density in Bamberg and Hallstadt. We selected 60 damaged trees, in addition to 30 randomly selected trees and 30 trees in low radiation areas (n=120) in this polygon. The measurements of all trees revealed significant differences between the damaged side facing a phone mast and the opposite side, as well as differences between the exposed side of damaged trees and all other groups of trees in both sides. Thus, we found that side differences in measured values of power flux density corresponded to side differences in damage. The 30 selected trees in low radiation areas (no visual contact to any phone mast and power flux density under 50μW/m 2 ) showed no damage. Statistical analysis demonstrated that electromagnetic radiation from mobile phone masts is harmful for trees. These results are consistent with the fact

  12. Efficacy evaluation of laparoscopy assisted ultrasound guided radiofrequency ablation in the treatment of hepatocellular carcinoma beneath the diaphragm

    Directory of Open Access Journals (Sweden)

    Song WANG

    2017-06-01

    Full Text Available Objective To explore the feasibility, safety and efficacy of laparoscopy assisted ultrasound guided radiofrequency ablation (RFA in the treatment of hepatocellular carcinoma (HCC beneath the diaphragm. Methods Twenty- three consecutive patients with solitary HCC beneath the diaphragm were treated by laparoscopy assisted ultrasound guided RFA in the Chinese PLA General Hospital from January 2013 to March 2016. We observed the perioperative complications and followed- up long-term effect. Results All the 23 patients successfully underwent laparoscopy assisted ultrasound guided radiofrequency ablation. No serious complications such as massive hemorrhage, biliary fistula and severe pleural effusion, hemopneumothorax occurred in the patients during perioperative period. CT examination 2-3 days after the operation revealed that the tumor was completely covered by the ablation area. Besides, the survival condition was satisfactory during follow-up period of 9-38 months. Conclusion Laparoscopy-assisted ultrasound-guided radiofrequency ablation is effective and safe for HCC beneath the diaphragm. DOI: 10.11855/j.issn.0577-7402.2017.05.16

  13. Automatic sample changers maintenance manual

    International Nuclear Information System (INIS)

    Myers, T.A.

    1978-10-01

    This manual describes and provides trouble-shooting aids for the Automatic Sample Changer electronics on the automatic beta counting system, developed by the Los Alamos Scientific Laboratory Group CNC-11. The output of a gas detector is shaped by a preamplifier, then is coupled to an amplifier. Amplifier output is discriminated and is the input to a scaler. An identification number is associated with each sample. At a predetermined count length, the identification number, scaler data plus other information is punched out on a data card. The next sample to be counted is automatically selected. The beta counter uses the same electronics as the prior count did, the only difference being the sample identification number and sample itself. This manual is intended as a step-by-step aid in trouble-shooting the electronics associated with positioning the sample, counting the sample, and getting the needed data punched on an 80-column data card

  14. Radio-frequency quadrupole: general properties and specific applications

    International Nuclear Information System (INIS)

    Stokes, R.H.; Crandall, K.R.; Hamm, R.W.

    1980-01-01

    The radio-frequency quadrupole (RFQ) linac structure is being developed for the acceleration of low-velocity ions. Recent experimental tests have confirmed its expected performance and have led to an increased interest in a wide range of possible applications. The general properties of RFQ accelerators are reviewed and beam dynamics simulation results are presented for their use in a variety of accelerating systems. These include the low-beta sections of the Fusion Materials Irradiation Test Accelerator, a 200-MHz proton linear accelerator, and a xenon accelerator for heavy ion fusion

  15. Measurement and modelling of a radiofrequency micro-thruster

    International Nuclear Information System (INIS)

    Charles, C; Boswell, R W

    2012-01-01

    A capacitively coupled radiofrequency (rf) (13.56 MHz) cylindrical argon micro-discharge expanding into a larger glass tube is studied by performing optical and electrical measurements over a pressure range 0.3–5 Torr and a rf power range 5–40 W. Measurements of the axial and radial plasma density profiles at the Paschen minimum near 1.5 Torr are used to develop a global model of the discharge and estimate neutral heating from ion–neutral charge exchange collisions for micro-propulsion applications. (fast track communication)

  16. Role of regional radiofrequency hyperthermia after hepatic artery block in the normal pit liver

    International Nuclear Information System (INIS)

    Luo Jingwei; Xu Guozhen; Xiong Jinghong; Liu Xiaoyun; Wang Weihu; Li Yexiong

    2003-01-01

    Objective: To study the temperature difference, tolerated high temperature, pathological changes between normal and blocked hepatic artery in radiofrequency hyperthermia for pig liver. Methods: Mature pig was used with iodine blocked right hepatic artery. Heat of the whole liver was given for 1 hour by SR-1000 radiofrequency hyperthermia with four thermocouple probes to measure the temperature of the right hepatic artery, right and left normal liver and rectum. Results: Temperature of blocked right liver increased by 10.2 degree C from 39.1 degree C to 49.3 degree C as compared with the left liver of which the temperature rose by 6.8 degree C from 39.7 degree C to 46.5 degree C but the temperature of right hepatic artery and rectum rose only by 3.3 degree C, 3.2 degree C respectively. After sacrificing the pig one week later, on lobe exploration, severe necrosis was observed in the right lobe but the left lobe was normal with a clear demarcation between the two lobes. Conclusions: Hepatic arterial iodine embolization potentiates radiofrequency hyperthermia in the liver. Liver with blocked artery showed conspicuous necrosis but liver with normal un-blocked artery was able to tolerate 46.5 degree C. This provides some evidence for the combination of regional hyperthermia and hepatic artery block in the treatment of advanced liver cancer

  17. Structural properties of nitrogenated amorphous carbon films: Influence of deposition temperature and radiofrequency discharge power

    International Nuclear Information System (INIS)

    Lazar, G.; Bouchet-Fabre, B.; Zellama, K.; Clin, M.; Ballutaud, D.; Godet, C.

    2008-01-01

    The structural properties of nitrogenated amorphous carbon deposited by radiofrequency magnetron sputtering of graphite in pure N 2 plasma are investigated as a function of the substrate temperature and radiofrequency discharge power. The film composition is derived from x-ray photoemission spectroscopy, nuclear reaction analysis and elastic recoil detection measurements and the film microstructure is discussed using infrared, Raman, x-ray photoemission and near edge x-ray absorption fine structure spectroscopic results. At low deposition temperature and low radiofrequency power, the films are soft, porous, and easily contaminated with water vapor and other atmospheric components. The concentration of nitrogen in the films is very large for low deposition temperatures (∼33.6 at. % N at 150 deg. C) but decreases strongly when the synthesis temperature increases (∼15 at. % N at 450 deg. C). With increasing deposition temperature and discharge power values, the main observed effects in amorphous carbon nitride alloys are a loss of nitrogen atoms, a smaller hydrogen and oxygen contamination related to the film densification, an increased order of the aromatic sp 2 phase, and a strong change in the nitrogen distribution within the carbon matrix. Structural changes are well correlated with modifications of the optical and transport properties

  18. Parallel simulation of radio-frequency plasma discharges

    International Nuclear Information System (INIS)

    Fivaz, M.; Howling, A.; Ruegsegger, L.; Schwarzenbach, W.; Baeumle, B.

    1994-01-01

    The 1D Particle-In-Cell and Monte Carlo collision code XPDP1 is used to model radio-frequency argon plasma discharges. The code runs faster on a single-user parallel system called MUSIC than on a CRAY-YMP. The low cost of the MUSIC system allows a 24-hours-per-day use and the simulation results are available one to two orders of magnitude quicker than with a super computer shared with other users. The parallelization strategy and its implementation are discussed. Very good agreement is found between simulation results and measurements done in an experimental argon discharge. (author) 2 figs., 3 refs

  19. Quantitative measurement of radiofrequency volumetric tissue reduction by multidetector CT in patients with inferior turbinate hypertrophy.

    Science.gov (United States)

    Bahadir, Osman; Kosucu, Polat

    2012-12-01

    To objectively assess the efficacy of radiofrequency thermal ablation of inferior turbinate hypertrophy. Thirty-five patients with nasal obstruction secondary to inferior turbinate hypertrophy were prospectively enrolled. Radiofrequency energy was delivered to four sites in each inferior turbinate. Patients were evaluated before and 8 weeks after intervention. Subjective evaluation of nasal obstruction was performed using a visual analogue scale (VAS), and objective evaluation of the turbinate volume reduction was calculated using multidetector CT. Volumetric measurements of the preoperative inferior turbinate were compared with postoperative values on both sides. The great majority of patients (91.4%) exhibited subjective postoperative improvement. Mean obstruction (VAS) improved significantly from 7.45±1.48 to 3.54±1.96. Significant turbinate volume reduction was achieved by the surgery on both right and left sides [(preoperative vs. postoperative, right: 6.55±1.62cm(3) vs. 5.10±1.47cm(3), (PRadiofrequency is a safe and effective surgical procedure in reducing turbinate volume in patients with inferior turbinate hypertrophy. Multidetector CT is an objective method of assessment in detecting radiofrequency turbinate volume reduction. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  20. Using Web2.0 social network technology for sampling framework identification and respondent recruitment: experiences with a small-scale experiment

    NARCIS (Netherlands)

    Grigolon, A.B.; Kemperman, A.D.A.M.; Timmermans, H.J.P.

    2011-01-01

    In this paper, we report the results of a small–scale experiment to explore the potential of using social network technology for respondent recruitment. Of particular interest are the following questions (i) can social media be used for the identification of sampling frames, (ii) what response rates

  1. High radiofrequency radiation at Stockholm Old Town: An exposimeter study including the Royal Castle, Supreme Court, three major squares and the Swedish Parliament

    OpenAIRE

    Hardell, Lennart; Carlberg, Michael; Koppel, Tarmo; Hedendahl, Lena

    2017-01-01

    Exposure to radiofrequency (RF) radiation was classified as a possible human carcinogen, Group 2B, by the International Agency for Research on Cancer at WHO in 2011. The exposure pattern is changing due to the rapid development of technology. Outdoor RF radiation level was measured during five tours in Stockholm Old Town in April, 2016 using the EME Spy 200 exposimeter with 20 predefined frequencies. The results were based on 10,437 samples in total. The mean level of the total RF radiation w...

  2. Dielectric-filled radiofrequency linacs

    Energy Technology Data Exchange (ETDEWEB)

    Faehl, R J; Keinigs, R K; Pogue, E W [Los Alamos National Lab., NM (United States)

    1997-12-31

    High current, high brightness electron beam accelerators promise to open up dramatic new applications. Linear induction accelerators are currently viewed as the appropriate technology for these applications. A concept by Humphries and Hwang may permit radiofrequency accelerators to fulfill the same functions with greater simplicity and enhanced flexibility. This concept involves the replacement of vacuum rf cavities with dielectric filled ones. Simple analysis indicates that the resonant frequencies are reduced by a factor of ({epsilon}{sub 0}/{epsilon}){sup 1/2} while the stored energy is increased by {epsilon}/{epsilon}{sub 0}. For a high dielectric constant like water, this factor can approach 80. A series of numerical calculations of simple pill-box cavities was performed. Eigenfunctions and resonant frequencies for a full system configuration, including dielectric material, vacuum beamline, and a ceramic window separating the two have been computed. These calculations are compared with the results of a small experimental cavity which have been constructed and operated. Low power tests show excellent agreement. (author). 4 figs., 8 refs.

  3. [Clinical effect of bipolar radiofrequency thermotherapy on allergic rhinitis].

    Science.gov (United States)

    Oyake, Daisuke; Ochi, Kentaro; Takatsu, Mitsuharu; Shintani, Toshiharu; Umehara, Tsuyoshi; Koizuka, Izumi

    2004-07-01

    The clinical effect of bipolar radiofrequency thermotherapy on allergic rhinitis was evaluated. A bipolar radiofrequency system (CelonLab ENT) was used to treat 16 patients suffering from allergic rhinitis between February 2003 and August 2003. The thermotherapy was performed under local anesthesia at the otolaryngology outpatient clinic of St. Marianna University Toyoko Hospital. Data were collected by questionnaire and rhinomanometry preoperatively and 2 months postoperatively. The mean visual analogue scale (VAS) score for intraoperative pain was 31 mm (range, 0-100), and nearly all the patients felt no or a subtle pain during the thermotherapy. Postoperative pain was also well tolerated, with nearly all the patients not requiring analgesic drugs. Postoperative bleeding was minor, and none of the patients required additional treatment for bleeding. Nearly all the patients reported an improvement in their nasal patency, rhinorrhea, headaches, and sleeping. Statistically significant improvements were observed for all the measured VAS scores: nasal patency, rhinorrhea, headache, and olfactory function. Nasal resistance, as measured by anterior rhinomanometry, significantly improved after treatment. The effect of decongestion was also measured using anterior rhinomanometry. The ratio of nasal resistance before and after decongestion was significantly higher after thermotherapy, suggesting that nasal decongestion had a smaller effect on nasal patency after treatment. The current results suggest that the CelonLab ENT device is an effective and safe treatment for allergic rhinitis.

  4. Performance Assessment of the CapitalBio Mycobacterium Identification Array System for Identification of Mycobacteria

    Science.gov (United States)

    Liu, Jingbo; Yan, Zihe; Han, Min; Han, Zhijun; Jin, Lingjie; Zhao, Yanlin

    2012-01-01

    The CapitalBio Mycobacterium identification microarray system is a rapid system for the detection of Mycobacterium tuberculosis. The performance of this system was assessed with 24 reference strains, 486 Mycobacterium tuberculosis clinical isolates, and 40 clinical samples and then compared to the “gold standard” of DNA sequencing. The CapitalBio Mycobacterium identification microarray system showed highly concordant identification results of 100% and 98.4% for Mycobacterium tuberculosis complex (MTC) and nontuberculous mycobacteria (NTM), respectively. The sensitivity and specificity of the CapitalBio Mycobacterium identification array for identification of Mycobacterium tuberculosis isolates were 99.6% and 100%, respectively, for direct detection and identification of clinical samples, and the overall sensitivity was 52.5%. It was 100% for sputum, 16.7% for pleural fluid, and 10% for bronchoalveolar lavage fluid, respectively. The total assay was completed in 6 h, including DNA extraction, PCR, and hybridization. The results of this study confirm the utility of this system for the rapid identification of mycobacteria and suggest that the CapitalBio Mycobacterium identification array is a molecular diagnostic technique with high sensitivity and specificity that has the capacity to quickly identify most mycobacteria. PMID:22090408

  5. Measurement of sample temperatures under magic-angle spinning from the chemical shift and spin-lattice relaxation rate of 79Br in KBr powder.

    Science.gov (United States)

    Thurber, Kent R; Tycko, Robert

    2009-01-01

    Accurate determination of sample temperatures in solid state nuclear magnetic resonance (NMR) with magic-angle spinning (MAS) can be problematic, particularly because frictional heating and heating by radio-frequency irradiation can make the internal sample temperature significantly different from the temperature outside the MAS rotor. This paper demonstrates the use of (79)Br chemical shifts and spin-lattice relaxation rates in KBr powder as temperature-dependent parameters for the determination of internal sample temperatures. Advantages of this method include high signal-to-noise, proximity of the (79)Br NMR frequency to that of (13)C, applicability from 20 K to 320 K or higher, and simultaneity with adjustment of the MAS axis direction. We show that spin-lattice relaxation in KBr is driven by a quadrupolar mechanism. We demonstrate a simple approach to including KBr powder in hydrated samples, such as biological membrane samples, hydrated amyloid fibrils, and hydrated microcrystalline proteins, that allows direct assessment of the effects of frictional and radio-frequency heating under experimentally relevant conditions.

  6. Radiofrequency ablation versus resection for Barcelona clinic liver cancer very early/early stage hepatocellular carcinoma: a systematic review.

    Science.gov (United States)

    He, Zhen-Xin; Xiang, Pu; Gong, Jian-Ping; Cheng, Nan-Sheng; Zhang, Wei

    2016-01-01

    To compare the long-term survival outcomes of radiofrequency ablation and liver resection for single very early/early stage hepatocellular carcinoma (HCC). The Cochrane Library (Issue 3, 2015), Embase (1974 to March 15, 2015), PubMed (1950 to March 15, 2015), Web of Science (1900 to March 15, 2015), and Chinese Biomedical Literature Database (1978 to March 15, 2015) were searched to identify relevant trials. Only trials that compared radiofrequency ablation and liver resection for single very early stage (≤2 cm) or early stage (≤3 cm) HCC according to the Barcelona clinic liver cancer (BCLC) staging system were considered for inclusion in this review. The primary outcomes that we analyzed were the 3-year and 5-year overall survival (OS) rates, and the secondary outcomes that we analyzed were the 3-year and 5-year disease-free survival (DFS) rates. Review Manager 5.3 was used to perform a cumulative meta-analysis. Possible publication bias was examined using a funnel plot. A random-effects model was applied to summarize the various outcomes. Six studies involving 947 patients were identified that compared radiofrequency ablation (n=528) to liver resection (n=419) for single BCLC very early HCC. In these six studies, the rates of 3-year OS, 5-year OS, 3-year DFS, and 5-year DFS were significantly lower in the radiofrequency ablation group than in the liver resection group (risk ratio [RR] =0.90, 95% confidence interval [CI]: 0.83-0.98, P=0.01; RR =0.84, 95% CI: 0.75-0.95, P=0.004; RR =0.77, 95% CI: 0.60-0.98, P=0.04; and RR =0.70, 95% CI: 0.52-0.94, P=0.02, respectively). Ten studies involving 2,501 patients were identified that compared radiofrequency ablation (n=1,476) to liver resection (n=1,025) for single BCLC early HCC. In these ten studies, the rates of 3-year OS, 5-year OS, 3-year DFS, and 5-year DFS were also significantly lower in the radiofrequency ablation group than in the liver resection group (RR =0.93, 95% CI: 0.88-0.98, P=0.003; RR =0.84, 95% CI

  7. High peak power processing up to 100 MV/M on various metallic samples

    International Nuclear Information System (INIS)

    Luong, M.; Bonin, B.; Safa, H.

    1996-01-01

    The high peak power processing (HPPP) is a well established way to reduce electronic field emission from radiofrequency (RF) metallic surfaces. The processing occurs because of some kind of instability destroys the emitter, but the basic physical mechanism at work has not yet been clearly identified. RF processing experiments on samples of restricted area, are described with well localized artificial emitting sites (protrusions from scratches on the sample surface). In order to disentangle the role of thermal and mechanical effects, in the processing, the samples were made from metals with different melting temperatures and tensile strengths. (author)

  8. High peak power processing up to 100 MV/m on various metallic samples

    International Nuclear Information System (INIS)

    Luong, M.; Bonin, B.; Safa, H.; Le Goff, A.

    1996-01-01

    The high peak power processing (HPPP) is a well established way to reduce electronic field emission from radiofrequency (RF) metallic surfaces. The processing occurs because of some kind of instability destroys the emitter, but the basic physical mechanism at work has not yet been clearly identified. The present study describes RF processing experiments on samples of restricted area, with well localized artificial emitting sites (protrusions from scratches on the sample surface). In order to disentangle the role of thermal and mechanical effects in the processing, the samples were made from metals with different melting temperatures and tensile strengths. (author)

  9. Perioperative outcomes of zero ischemia radiofrequency ablation-assisted tumor enucleation for renal cell carcinoma: results of 182 patients.

    Science.gov (United States)

    Zhang, Chengwei; Zhao, Xiaozhi; Guo, Suhan; Ji, Changwei; Wang, Wei; Guo, Hongqian

    2018-05-15

    To evaluate the perioperative outcomes of zero ischemia radiofrequency ablation-assisted tumor enucleation. Patients undergoing zero ischemia radiofrequency ablation-assisted tumor enucleation were retrospectively identified from July 2008 to March 2013. The tumor was enucleated after RFA treatment. R.E.N.A.L., PADUA and centrality index (C-index) score systems were used to assess each tumor case. We analyzed the correlation of perioperative outcomes with these scores. Postoperative complications were graded with Clavien-Dindo system. Multivariate logistic regression analyses were used to assess risk of complications. Among 182 patients assessed, median tumor size, estimated blood loss, hospital stay and operative time were 3.2 cm (IQR 2.8-3.4), 80 ml (IQR 50-120), 7 days (IQR 6-8) and 100 min (IQR 90-120), respectively. All three scoring systems were strongly correlated with estimated blood loss, hospital stay and operative time. We found 3 (1.6%) intraoperative and 23 (12.6%, 13 [7.1%] Grade 1 and 10 [5.5%] Grade 2 & 3a) postoperative complications. The median follow-up was 55.5 months (IQR 45-70). Additionally, the complexities of R.E.N.A.L., PADUA and C-index scores were significantly correlated with complication grades (P radiofrequency ablation-assisted tumor enucleation is considered an effective nephron-sparing treatment. Scoring systems could be useful for predicting perioperative outcomes of radiofrequency ablation-assisted tumor enucleation.

  10. Measurements of energetic helium-3 minority distributions during ion cyclotron radiofrequency heating in the Princeton large torus

    International Nuclear Information System (INIS)

    Hammett, G.W.; Kaita, R.; Wilson, J.R.

    1988-01-01

    Ion cyclotron radiofrequency heating experiments were performed with a 3 He minority ion species in a 4 He majority plasma in the Princeton Large Torus. The energetic 3 He ion 'tail' was measured directly with a charge exchange neutral analyser for the first time. Comparisons with bounce averaged quasi-linear calculations suggest a modestly peaked radiofrequency power deposition profile. The double charge exchange process 3 He ++ + 4 He o -> 3 He o + 4 He ++ demonstrated in these measurements may be useful as part of an alpha particle diagnostic in a fusion reactor experiment. (author). 21 refs, 4 figs

  11. Bile Duct Disruption Following Radiofrequency Ablation: Successful Repair Using a Covered Stent

    International Nuclear Information System (INIS)

    Thompson, Philip M.; Hare, Christopher M.B.; Lees, William R.

    2004-01-01

    Persistent biliary leaks, whether iatrogenic or secondary to malignancy, often present a difficult management problem. Recent reports have suggested a role for covered metallic stents in this context. We describe the successful use of a covered stent to seal a persistent biliary leak following radiofrequency ablation of colorectal liver metastases

  12. Contribution to the study of accelerating structure for electrons and respective radiofrequency couplers

    International Nuclear Information System (INIS)

    Franco, M.A.R.

    1991-01-01

    In this work, the experimental results pertaining to the construction and evaluation of a constant gradient accelerating structure and of the radiofrequency couplers are presented. The theoretical methods to determine the initial dimensions of the iris-loaded accelerating structure are presented. The final dimensions have been experimentally determined utilizing four three-cavity sections representing the 4 sup(th), 12 sup(th), 20 sup(th) and 27 sup(th) cavities of the final structure. The diameters of the cavities were corrected for variations of temperature, pressure and humidity. A v sub(p) = c, constant gradient, twelve-cavity prototype of the accelerating structure have been constructed and its principal parameters were experimentally determined according to methods also described in this work. Two prototypes of door-knob type radiofrequency couplers have been constructed and experimental procedures to match and tune the couplers and the accelerating structure were implemented. (author)

  13. Cooling system for the IFMIF-EVEDA radiofrequency system; Sistema de refrigeracion del sistema de radiofrecuencia del IFMIF-EVEDA

    Energy Technology Data Exchange (ETDEWEB)

    Perez Pichel, G. D.

    2012-07-01

    The IFMIF-EVEDA project consists on an accelerator prototype that will be installed at Rokkasho (Japan). Through CIEMAT, that is responsible of the development of many systems and components. Empresarios Agrupados get the responsibility of the detailed design of the cooling system for the radiofrequency system (RF system) that must feed the accelerator. the RF water cooling systems is the water primary circuit that provides the required water flow (with a certain temperature, pressure and water quality) and also dissipates the necessary thermal power of all the radiofrequency system equipment. (Author) 4 refs.

  14. Treatment of abdominal cellulite and circumference reduction with radiofrequency and dynamic muscle activation.

    Science.gov (United States)

    Wanitphakdeedecha, Rungsima; Iamphonrat, Thanawan; Thanomkitti, Kanchalit; Lektrakul, Nittaya; Manuskiatti, Woraphong

    2015-01-01

    Cellulite is a frequent skin condition for which treatment remains a challenge. A wide variety of treatments are available but most procedures offer suboptimal clinical effect and/or delayed therapeutic outcome. Only few therapeutic options have proven efficacy in the treatment of cellulite. To determine the efficacy and the safety profiles of radiofrequency and dynamic muscle activation technology in treatment of abdominal cellulite and circumference reduction. Twenty-five females with abdominal cellulite received 6 weekly radiofrequency and dynamic muscle activation treatments. Treatment areas included the abdomen and both sides of flanks. Subjects were evaluated using standardized photographs, and measurements of body weight and abdominal circumference at baseline, before every treatment visit, and 1 week and four weeks after the final treatment. Subcutaneous tissue thickness was recorded by ultrasound at baseline and 4 weeks after completion of treatment protocol. Physicians' evaluation and patient's satisfaction of clinical improvement were also measured. All subjects completed the treatment protocol and attended every follow-up visits. There was significant abdominal circumference reduction of 2.96 and 2.52 cm at 1-, and 4-week follow-up visits (p last treatment, the average circumferential reduction was sustained. Most of the patients were rated to have 25-49% improvement at 5th treatment, and 1- and 4-week follow-up visits. Ninety-two percent of the patients were satisfied with the treatment outcome. Radiofrequency provided beneficial effects on the reduction of abdomen and cellulite appearance. The benefit of muscle activation is yet to be determined.

  15. An experimental study on hepatic ablation using an expandable radio-frequency needle electrode

    International Nuclear Information System (INIS)

    Choi, Dong Il; Lim, Hyo Keun; Park, Jong Min; Kang, Bo Kyung; Woo, Ji Young; Jang, Hyun Jung; Kim, Seung Hoon; Lee, Won Jae; Park, Cheol Keun; Heo, Jin Seok

    1999-01-01

    The purpose of this study was to determine the factors influencing on the size of thermal lesions after ablation using an expendable radio-frequency needle electrode in porcine liver. Ablation procedures involved the use of a monopolar radio-frequency generator and 15-G needle electrodes with four and seven retractable hooks (RITA Medical System, Mountain View, Cal., U.S.A.). The ablation protocol in fresh porcine liver comprised of combinations of varying hook deployment, highest set temperature, and ablation time. Following ablation, the maximum diameter of all thermal lesions was measured on a longitudinal section of the specimen. Ten representive lesions were examined by an experienced pathologist. At 3-cm hook deployment of the needle electrode with four lateral hooks, the size of spherical thermal lesions increased substantially with increases in the highest set temperature and ablation time until 11 minutes. After 11 minutes lesion size remained similar, with a maximum diameter of 3.3 cm. At 2-cm hook deployment, sizes decreased to about 2/3 of those at 3 cm , and at 1-cm hook deployment lesions were oblong. At 3-cm hook deployment of a needle electrode with seven hooks, the size of thermal lesions increased with increasing ablation time until 14 minutes, and the maximum diameter was 4.1 cm. Microscopic examination showed a wide zone of degeneration and focal coagulation necrosis. The size of thermal lesions produced by the use of an expandable radio-frequency needle electrode were predictable, varying according to degree of hook deployment, highest set temperature, and ablation time

  16. CT-guided radiofrequency ablation of osteoid osteoma using a novel battery-powered drill

    Energy Technology Data Exchange (ETDEWEB)

    Schnapauff, Dirk; Streitparth, Florian; Wieners, Gero; Collettini, Federico; Hamm, Bernd; Gebauer, Bernhard [Charite Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany); Joehrens, Korinna [Charite Universitaetsmedizin Berlin, Department of Pathology, Berlin (Germany)

    2015-05-01

    To evaluate the use of a novel battery-powered drill, enabling specimen requirement while drilling, in radiofrequency ablation of osteoid osteoma as an alternative to conventional orthopedic drills. Between 2009 and 2013, altogether 33 patients underwent CT-guided radiofrequency ablation of an osteoid osteoma at our institution. To access the nidus of the clinically and radiologically suspected osteoid osteoma, a channel was drilled using the OnControl Bone Marrow Biopsy System (OBM, Arrow OnControl, Teleflex, Shavano Park, TX, USA) and a biopsy was taken. Procedure time (i.e., drilling including local anesthesia), amount of scans (i.e., single-shot fluoroscopy), radiation exposure, and the results of biopsy were investigated and compared retrospectively to a classical approach using either a manual bone biopsy system or a conventional orthopedic drill (n = 10) after ethical review board approval. Drilling the tract into the nidus was performed without problems in 22 of the 23 OBM cases. Median procedure time was 7 min compared to 13 min using the classical approach (p < 0.001). Median amount CT scans, performed to control correct positioning of the drill was comparable with 26 compared to 24.5 (p = NS) scans. Histologically, the diagnosis of osteoid osteomas could be determined in all 17 cases where a biopsy was taken. Radiofrequency ablation could be performed without problems in any case. The use of the battery-powered drill was feasible and facilitated the access to the osteoid osteoma's nidus offering the possibility to extract a specimen in the same step. (orig.)

  17. Percutaneous ultrasound-guided radiofrequency ablation for kidney tumors in patients with surgical risk

    International Nuclear Information System (INIS)

    Salagierski, Marek; Salagierski, Maciej; Sosnowski, Marek; Salagierska-Barwinska, Anna

    2006-01-01

    The aim of this study was to describe our experience with percutaneous ultrasound-guided radiofrequency ablation of kidney tumors. From July 2002 to August 2005, 45 radiofrequency ablations (RFA) in 42 selected patients with kidney tumor were performed. The patients had either contraindications to surgery procedures or had a solitary kidney. The average tumor size was 37.5 mm (range, 18-59 mm) with the mean age of 68 years (range, 28-83 years). RFA were performed based on radiographic findings. Needle biopsy was made only twice. Monopolar Cool-tip Tyco or bipolar Celon Olympus radiofrequency devices were used. The procedure was performed under conscious sedation with local anesthesia. Treatment efficacy was assessed by computed tomography and by Doppler ultrasound. The absence of contrast enhancement on computed tomography was considered to be a successful treatment. The average follow up was 14 months (range, 3-36 months). In 42 tumors (93%), total absence of contrast enhancement was obtained after the initial RFA and in three tumors (7%) after the second ablation session. There were no complications following 41 procedures, including all ablations in small (<35 mm) renal masses. In four procedures, minor complications were observed. All patients are alive. There has been no need for chronic hemodialysis and, until now, we have not observed any local recurrences with the exception of one metastasis to an ipsilateral adrenal gland. RFA of kidney tumors is a promising alternative treatment which could be considered for patients who are not suitable for surgery. (author)

  18. ECG changes in factory workers exposed to 27.2  MHz radiofrequency radiation.

    Science.gov (United States)

    Chen, Qingsong; Xu, Guoyong; Lang, Li; Yang, Aichu; Li, Shilin; Yang, Liwen; Li, Chaolin; Huang, Hanlin; Li, Tao

    2013-05-01

    To research the effect of 27.2 MHz radiofrequency radiation on electrocardiograms (ECG), 225 female workers operating radiofrequency machines at a shoe factory were chosen as the exposure group and 100 female workers without exposure from the same factory were selected as the control group. The 6 min electric field strength that the female workers were exposed to was 64.0 ± 25.2 V/m (mean ± SD), which exceeded 61 V/m, the International Commission on Non-Ionizing Radiation Protection reference root mean square levels for occupational exposure. A statistical difference was observed between the exposed group and the control group in terms of the rate of sinus bradycardia (χ(2)  = 11.48, P = 0.003). When several known risk factors for cardiovascular disease were considered, including smoking, age, alcohol ingestion habit, and so on, the exposure duration was not an effective factor for ECG changes, sinus arrhythmia, or sinus bradycardia according to α = 0.05, while P = 0.052 for sinus arrhythmia was very close to 0.05. We did not find any statistical difference in heart rate, duration of the QRS wave (ventricular depolarization), or corrected QT intervals (between the start of the Q wave and end of the T wave) between the exposed and control groups. Occupational exposure to radiofrequency radiation was not found to be a cause of ECG changes after consideration of the confounding factors. Copyright © 2012 Wiley Periodicals, Inc.

  19. Radiofrequency thermocoagulation of the thoracic splanchnic nerve in functional abdominal pain syndrome -A case report-.

    Science.gov (United States)

    Choi, Ji-Won; Joo, Eun-Young; Lee, Sang-Hyun; Lee, Chul-Joong; Kim, Tae-Hyeong; Sim, Woo-Seok

    2011-07-01

    The thoracic splanchnic nerve block has been used in managing abdominal pain, especially for pains arising from abdominal cancers. A 27-year-old male patient who had a constant abdominal pain was referred to our clinic for pain management but had no organic disease. The numeric rating scale (NRS) for pain scored 7/10. We applied a diagnostic thoracic splanchnic nerve block under the diagnosis of functional abdominal pain syndrome. Since the block reduced the pain, we applied a radiofrequency thermocoagulation at the T11 and T12 vertebral level. Thereafter, his symptoms improved markedly with pain decreasing to an NRS score of 2-3/10. Hereby, we report a successful management of functional abdominal pain via radiofrequency thermocoagulation of the thoracic splanchnic nerves.

  20. Image-guided radiofrequency ablation (RFA) of spinal tumors

    International Nuclear Information System (INIS)

    Gevargez, Athour; Groenemeyer, Dietrich H.W.

    2008-01-01

    Purpose: To evaluate retrospectively the efficacy and safety of radiofrequency ablation (RFA) in patients with spinal tumors. Materials and methods: Forty-one patients (25 men, 16 women; age range, 46-82 years) with nonresectable primary or secondary tumor involvement of the spine unresponsive to chemo- and radiotherapy received RFA treatment. Two radiofrequency ablation systems, one with a cool-tip electrode and one with an expandable electrode catheter, were used. Both systems work impedance controlled with a power output of 150- 200 W. Each coagulation cycle lasted 12-15 min depending on tumor impedance. Several single RFA cycles of 15 min each were used for overlapping RFAs in tumors with diameters of more than 3 cm. Temperature was kept between 50 deg. C and 120 deg. C and was chosen according to spinal cord distance and patient heat tolerance during the ablation. Multi-slice computed tomography (CT) combined with C-arm fluoroscopy guided the intervention. Efficacy outcomes were assessed after about 6 weeks, 6 months, and more than 6 months using standardized questionnaires and indices regarding tumor pain, pain disability, functional activities, quality of life, neurological status, and tumor progression. Results: RFA significantly reduced tumor-induced pain within 6 weeks, improved daily activities, and maintained quality of life. Mean time to tumor progression was 730 ± 54 days (Kaplan-Meier estimate). No RFA-associated complications were reported. Conclusion: RFA of primary and secondary spinal tumors, which were unresponsive to chemo- and radiotherapy and prone to progression, is a safe, resource-saving, and highly effective percutaneous technique in patients with nonresectable spinal tumors