WorldWideScience

Sample records for sample processing procedures

  1. Sample processing procedures and radiocarbon dating

    International Nuclear Information System (INIS)

    Svetlik, Ivo; Tomaskova, Lenka; Dreslerova, Dagmar

    2010-01-01

    The article outlines radiocarbon dating routines and highlights the potential and limitations of this method. The author's institutions have been jointly running a conventional radiocarbon dating laboratory using the international CRL code. A procedure based on the synthesis of benzene is used. Small samples are sent abroad for dating because no AMS instrumentation is available in the Czech Republic so far. Our laboratory plans to introduce routines for the processing of milligram samples and preparation of graphitized targets for AMS

  2. An improved ashing procedure for biologic sample

    Energy Technology Data Exchange (ETDEWEB)

    Zongmei, Wu [Zhejiang Province Enviromental Radiation Monitoring Centre (China)

    1992-07-01

    The classical ashing procedure in muffle was modified for biologic samples. In the modified procedure the door of muffle was open in the duration of ashing process, the ashing was accelerated and the ashing product quality was comparable to that the classical procedure. The modified procedure is suitable for ashing biologic samples in large batches.

  3. An improved ashing procedure for biologic sample

    International Nuclear Information System (INIS)

    Wu Zongmei

    1992-01-01

    The classical ashing procedure in muffle was modified for biologic samples. In the modified procedure the door of muffle was open in the duration of ashing process, the ashing was accelerated and the ashing product quality was comparable to that the classical procedure. The modified procedure is suitable for ashing biologic samples in large batches

  4. Sampling procedure, receipt and conservation of water samples to determine environmental radioactivity

    International Nuclear Information System (INIS)

    Herranz, M.; Navarro, E.; Payeras, J.

    2009-01-01

    The present document informs about essential goals, processes and contents that the subgroups Sampling and Samples Preparation and Conservation believe they should be part of the procedure to obtain a correct sampling, receipt, conservation and preparation of samples of continental, marine and waste water before qualifying its radioactive content.

  5. The effect of sample grinding procedures after processing on gas production profiles and end-product formation in expander processed barley and peas

    NARCIS (Netherlands)

    Azarfar, A.; Poel, van der A.F.B.; Tamminga, S.

    2007-01-01

    Grinding is a technological process widely applied in the feed manufacturing industry and is a prerequisite for obtaining representative samples for laboratory procedures (e.g. gas production analysis). When feeds are subjected to technological processes other than grinding (e.g. expander

  6. Specified assurance level sampling procedure

    International Nuclear Information System (INIS)

    Willner, O.

    1980-11-01

    In the nuclear industry design specifications for certain quality characteristics require that the final product be inspected by a sampling plan which can demonstrate product conformance to stated assurance levels. The Specified Assurance Level (SAL) Sampling Procedure has been developed to permit the direct selection of attribute sampling plans which can meet commonly used assurance levels. The SAL procedure contains sampling plans which yield the minimum sample size at stated assurance levels. The SAL procedure also provides sampling plans with acceptance numbers ranging from 0 to 10, thus, making available to the user a wide choice of plans all designed to comply with a stated assurance level

  7. Sample and data management process description

    International Nuclear Information System (INIS)

    Kessner, J.H.

    2000-01-01

    The sample and data management process was initiated in 1994 as a result of a process improvement workshop. The purpose of the workshop was to develop a sample and data management process that would reduce cycle time and costs, simplify systems and procedures, and improve customer satisfaction for sampling, analytical services, and data management activities

  8. Procedures for sampling radium-contaminated soils

    International Nuclear Information System (INIS)

    Fleischhauer, H.L.

    1985-10-01

    Two procedures for sampling the surface layer (0 to 15 centimeters) of radium-contaminated soil are recommended for use in remedial action projects. Both procedures adhere to the philosophy that soil samples should have constant geometry and constant volume in order to ensure uniformity. In the first procedure, a ''cookie cutter'' fashioned from pipe or steel plate, is driven to the desired depth by means of a slide hammer, and the sample extracted as a core or plug. The second procedure requires use of a template to outline the sampling area, from which the sample is obtained using a trowel or spoon. Sampling to the desired depth must then be performed incrementally. Selection of one procedure over the other is governed primarily by soil conditions, the cookie cutter being effective in nongravelly soils, and the template procedure appropriate for use in both gravelly and nongravelly soils. In any event, a minimum sample volume of 1000 cubic centimeters is recommended. The step-by-step procedures are accompanied by a description of the minimum requirements for sample documentation. Transport of the soil samples from the field is then addressed in a discussion of the federal regulations for shipping radioactive materials. Interpretation of those regulations, particularly in light of their application to remedial action soil-sampling programs, is provided in the form of guidance and suggested procedures. Due to the complex nature of the regulations, however, there is no guarantee that our interpretations of them are complete or entirely accurate. Preparation of soil samples for radium-226 analysis by means of gamma-ray spectroscopy is described

  9. Soil Sampling Operating Procedure

    Science.gov (United States)

    EPA Region 4 Science and Ecosystem Support Division (SESD) document that describes general and specific procedures, methods, and considerations when collecting soil samples for field screening or laboratory analysis.

  10. 42 CFR 431.814 - Sampling plan and procedures.

    Science.gov (United States)

    2010-10-01

    ... reliability of the reduced sample. (4) The sample selection procedure. Systematic random sampling is... sampling, and yield estimates with the same or better precision than achieved in systematic random sampling... 42 Public Health 4 2010-10-01 2010-10-01 false Sampling plan and procedures. 431.814 Section 431...

  11. k-Means: Random Sampling Procedure

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. k-Means: Random Sampling Procedure. Optimal 1-Mean is. Approximation of Centroid (Inaba et al). S = random sample of size O(1/ ); Centroid of S is a (1+ )-approx centroid of P with constant probability.

  12. Soil Gas Sampling Operating Procedure

    Science.gov (United States)

    EPA Region 4 Science and Ecosystem Support Division (SESD) document that describes general and specific procedures, methods, and considerations when collecting soil gas samples for field screening or laboratory analysis.

  13. Continuous quality control of the blood sampling procedure using a structured observation scheme

    DEFF Research Database (Denmark)

    Seemann, T. L.; Nybo, M.

    2015-01-01

    Background: An important preanalytical factor is the blood sampling procedure and its adherence to the guidelines, i.e. CLSI and ISO 15189, in order to ensure a consistent quality of the blood collection. Therefore, it is critically important to introduce quality control on this part of the process....... As suggested by the EFLM working group on the preanalytical phase we introduced continuous quality control of the blood sampling procedure using a structured observation scheme to monitor the quality of blood sampling performed on an everyday basis. Materials and methods: Based on our own routines the EFLM....... Conclusion: It is possible to establish a continuous quality control on blood sampling. It has been well accepted by the staff and we have already been able to identify critical areas in the sampling process. We find that continuous auditing increase focus on the quality of blood collection which ensures...

  14. Comparison of transition-matrix sampling procedures

    DEFF Research Database (Denmark)

    Yevick, D.; Reimer, M.; Tromborg, Bjarne

    2009-01-01

    We compare the accuracy of the multicanonical procedure with that of transition-matrix models of static and dynamic communication system properties incorporating different acceptance rules. We find that for appropriate ranges of the underlying numerical parameters, algorithmically simple yet high...... accurate procedures can be employed in place of the standard multicanonical sampling algorithm....

  15. IXM gas sampling procedure

    International Nuclear Information System (INIS)

    Pingel, L.A.

    1995-01-01

    Ion Exchange Modules (IXMs) are used at the 105-KE and -KW Fuel Storage Basins to control radionuclide concentrations in the water. A potential safety concern relates to production of hydrogen gas by radiolysis of the water trapped in the ion exchange media of spent IXMs. This document provides a procedure for sampling the gases in the head space of the IXM

  16. Sample preparation procedures utilized in microbial metabolomics: An overview.

    Science.gov (United States)

    Patejko, Małgorzata; Jacyna, Julia; Markuszewski, Michał J

    2017-02-01

    Bacteria are remarkably diverse in terms of their size, structure and biochemical properties. Due to this fact, it is hard to develop a universal method for handling bacteria cultures during metabolomic analysis. The choice of suitable processing methods constitutes a key element in any analysis, because only appropriate selection of procedures may provide accurate results, leading to reliable conclusions. Because of that, every analytical experiment concerning bacteria requires individually and very carefully planned research methodology. Although every study varies in terms of sample preparation, there are few general steps to follow while planning experiment, like sampling, separation of cells from growth medium, stopping their metabolism and extraction. As a result of extraction, all intracellular metabolites should be washed out from cell environment. What is more, extraction method utilized cannot cause any chemical decomposition or degradation of the metabolome. Furthermore, chosen extraction method should correlate with analytical technique, so it will not disturb or prolong following sample preparation steps. For those reasons, we observe a need to summarize sample preparation procedures currently utilized in microbial metabolomic studies. In the presented overview, papers concerning analysis of extra- and intracellular metabolites, published over the last decade, have been discussed. Presented work gives some basic guidelines that might be useful while planning experiments in microbial metabolomics. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Differences in metabolite profiles caused by pre-analytical blood processing procedures.

    Science.gov (United States)

    Nishiumi, Shin; Suzuki, Makoto; Kobayashi, Takashi; Yoshida, Masaru

    2018-05-01

    Recently, the use of metabolomic analysis of human serum and plasma for biomarker discovery and disease diagnosis in clinical studies has been increasing. The feasibility of using a metabolite biomarker for disease diagnosis is strongly dependent on the metabolite's stability during pre-analytical blood processing procedures, such as serum or plasma sampling and sample storage prior to centrifugation. However, the influence of blood processing procedures on the stability of metabolites has not been fully characterized. In the present study, we compared the levels of metabolites in matched human serum and plasma samples using gas chromatography coupled with mass spectrometry and liquid chromatography coupled with mass spectrometry. In addition, we evaluated the changes in plasma metabolite levels induced by storage at room temperature or at a cold temperature prior to centrifugation. As a result, it was found that 76 metabolites exhibited significant differences between their serum and plasma levels. Furthermore, the pre-centrifugation storage conditions significantly affected the plasma levels of 45 metabolites. These results highlight the importance of blood processing procedures during metabolome analysis, which should be considered during biomarker discovery and the subsequent use of biomarkers for disease diagnosis. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  18. Recommended practice for process sampling for partial pressure analysis

    International Nuclear Information System (INIS)

    Blessing, James E.; Ellefson, Robert E.; Raby, Bruce A.; Brucker, Gerardo A.; Waits, Robert K.

    2007-01-01

    This Recommended Practice describes and recommends various procedures and types of apparatus for obtaining representative samples of process gases from >10 -2 Pa (10 -4 Torr) for partial pressure analysis using a mass spectrometer. The document was prepared by a subcommittee of the Recommended Practices Committee of the American Vacuum Society. The subcommittee was comprised of vacuum users and manufacturers of mass spectrometer partial pressure analyzers who have practical experience in the sampling of process gas atmospheres

  19. Rapid radiochemical procedures for a process support laboratory

    International Nuclear Information System (INIS)

    Beals, D.M.

    1998-01-01

    An on-site mobile laboratory has been installed near a groundwater treatment facility, and rapid analytical procedures have been deployed for determining sample activity in the process support laboratory. The required analyses to support the remediation project include gross alpha/, gross nonvolatile beta, 90 Sr, 99 Tc, 137 Cs and total Ra (226 + 228). The present mission of the Savannah River Site (SRS), a US Department of Energy nuclear production facility, is one of nuclear waste stabilization and of environmental restoration and remediation. Because of previous practices of disposing low-level radioactive waste to seepage basins, some of the groundwater under the SRS has become contaminated with radioactive species. A water treatment facility has been installed to remediate the groundwater below the old F and H areas' seepage basins. Groundwater is pumped from the contaminated aquifer through a series of filtration, ion exchange, and reverse osmosis steps and when cleaned is reinjected back into the aquifer. Samples are pulled from various points in the treatment facility to ensure that the process is working as designed. In order to minimize turnaround time for these analyses, a process control station (i.e., a mobile on-site laboratory) has been installed at the F area water treatment unit, and rapid radioanalytical procedures have been deployed

  20. Automatic sample changer control software for automation of neutron activation analysis process in Malaysian Nuclear Agency

    Science.gov (United States)

    Yussup, N.; Ibrahim, M. M.; Rahman, N. A. A.; Mokhtar, M.; Salim, N. A. A.; Soh@Shaari, S. C.; Azman, A.; Lombigit, L.; Azman, A.; Omar, S. A.

    2018-01-01

    Most of the procedures in neutron activation analysis (NAA) process that has been established in Malaysian Nuclear Agency (Nuclear Malaysia) since 1980s were performed manually. These manual procedures carried out by the NAA laboratory personnel are time consuming and inefficient especially for sample counting and measurement process. The sample needs to be changed and the measurement software needs to be setup for every one hour counting time. Both of these procedures are performed manually for every sample. Hence, an automatic sample changer system (ASC) that consists of hardware and software is developed to automate sample counting process for up to 30 samples consecutively. This paper describes the ASC control software for NAA process which is designed and developed to control the ASC hardware and call GammaVision software for sample measurement. The software is developed by using National Instrument LabVIEW development package.

  1. Design aspects of automation system for initial processing of fecal samples

    International Nuclear Information System (INIS)

    Sawant, Pramilla D.; Prabhu, Supreetha P.; Suja, A.; Wankhede, Sonal; Chaudhary, Seema; Rao, D.D.; Pradeepkumar, K.S.; Das, A.P.; Badodkar, B.D.

    2014-01-01

    The procedure for initial handling of the fecal samples at Bioassay Lab., Trombay is as follows: overnight fecal samples are collected from the worker in a kit consisting of a polythene bag placed in a wide mouth polythene container closed with an inner lid and a screw cap. Occupational worker collects the sample in the polythene bag. On receiving the sample, the polythene container along with the sample is weighed, polythene bag containing fecal sample is lifted out of the container using a pair of tongs placed inside a crucible and ashed inside a muffle furnace at 450℃. After complete ashing, the crucible containing white ash is taken-up for further radiochemical processing. This paper describes the various steps in developing a prototype automated system for initial handling of fecal samples. The proposed system for handling and processing of fecal samples is proposed to automate the above. The system once developed will help eliminate manual intervention till the ashing stage and reduce the biological hazard involved in handling such samples mentioned procedure

  2. Comparison of VFA titration procedures used for monitoring the biogas process.

    Science.gov (United States)

    Lützhøft, Hans-Christian Holten; Boe, Kanokwan; Fang, Cheng; Angelidaki, Irini

    2014-05-01

    Titrimetric determination of volatile fatty acids (VFAs) contents is a common way to monitor a biogas process. However, digested manure from co-digestion biogas plants has a complex matrix with high concentrations of interfering components, resulting in varying results when using different titration procedures. Currently, no standardized procedure is used and it is therefore difficult to compare the performance among plants. The aim of this study was to evaluate four titration procedures (for determination of VFA-levels of digested manure samples) and compare results with gas chromatographic (GC) analysis. Two of the procedures are commonly used in biogas plants and two are discussed in literature. The results showed that the optimal titration results were obtained when 40 mL of four times diluted digested manure was gently stirred (200 rpm). Results from samples with different VFA concentrations (1-11 g/L) showed linear correlation between titration results and GC measurements. However, determination of VFA by titration generally overestimated the VFA contents compared with GC measurements when samples had low VFA concentrations, i.e. around 1 g/L. The accuracy of titration increased when samples had high VFA concentrations, i.e. around 5 g/L. It was further found that the studied ionisable interfering components had lowest effect on titration when the sample had high VFA concentration. In contrast, bicarbonate, phosphate and lactate had significant effect on titration accuracy at low VFA concentration. An extended 5-point titration procedure with pH correction was best to handle interferences from bicarbonate, phosphate and lactate at low VFA concentrations. Contrary, the simplest titration procedure with only two pH end-points showed the highest accuracy among all titration procedures at high VFA concentrations. All in all, if the composition of the digested manure sample is not known, the procedure with only two pH end-points should be the procedure of

  3. Procedures for cryogenic X-ray ptychographic imaging of biological samples.

    Science.gov (United States)

    Yusuf, M; Zhang, F; Chen, B; Bhartiya, A; Cunnea, K; Wagner, U; Cacho-Nerin, F; Schwenke, J; Robinson, I K

    2017-03-01

    Biological sample-preparation procedures have been developed for imaging human chromosomes under cryogenic conditions. A new experimental setup, developed for imaging frozen samples using beamline I13 at Diamond Light Source, is described. This manuscript describes the equipment and experimental procedures as well as the authors' first ptychographic reconstructions using X-rays.

  4. Stationary and related stochastic processes sample function properties and their applications

    CERN Document Server

    Cramér, Harald

    2004-01-01

    This graduate-level text offers a comprehensive account of the general theory of stationary processes, with special emphasis on the properties of sample functions. Assuming a familiarity with the basic features of modern probability theory, the text develops the foundations of the general theory of stochastic processes, examines processes with a continuous-time parameter, and applies the general theory to procedures key to the study of stationary processes. Additional topics include analytic properties of the sample functions and the problem of time distribution of the intersections between a

  5. Procedures for cryogenic X-ray ptychographic imaging of biological samples

    Directory of Open Access Journals (Sweden)

    M. Yusuf

    2017-03-01

    Full Text Available Biological sample-preparation procedures have been developed for imaging human chromosomes under cryogenic conditions. A new experimental setup, developed for imaging frozen samples using beamline I13 at Diamond Light Source, is described. This manuscript describes the equipment and experimental procedures as well as the authors' first ptychographic reconstructions using X-rays.

  6. Sampling design and procedures for fixed surface-water sites in the Georgia-Florida coastal plain study unit, 1993

    Science.gov (United States)

    Hatzell, H.H.; Oaksford, E.T.; Asbury, C.E.

    1995-01-01

    The implementation of design guidelines for the National Water-Quality Assessment (NAWQA) Program has resulted in the development of new sampling procedures and the modification of existing procedures commonly used in the Water Resources Division of the U.S. Geological Survey. The Georgia-Florida Coastal Plain (GAFL) study unit began the intensive data collection phase of the program in October 1992. This report documents the implementation of the NAWQA guidelines by describing the sampling design and procedures for collecting surface-water samples in the GAFL study unit in 1993. This documentation is provided for agencies that use water-quality data and for future study units that will be entering the intensive phase of data collection. The sampling design is intended to account for large- and small-scale spatial variations, and temporal variations in water quality for the study area. Nine fixed sites were selected in drainage basins of different sizes and different land-use characteristics located in different land-resource provinces. Each of the nine fixed sites was sampled regularly for a combination of six constituent groups composed of physical and chemical constituents: field measurements, major ions and metals, nutrients, organic carbon, pesticides, and suspended sediments. Some sites were also sampled during high-flow conditions and storm events. Discussion of the sampling procedure is divided into three phases: sample collection, sample splitting, and sample processing. A cone splitter was used to split water samples for the analysis of the sampling constituent groups except organic carbon from approximately nine liters of stream water collected at four fixed sites that were sampled intensively. An example of the sample splitting schemes designed to provide the sample volumes required for each sample constituent group is described in detail. Information about onsite sample processing has been organized into a flowchart that describes a pathway for each of

  7. Role of microextraction sampling procedures in forensic toxicology.

    Science.gov (United States)

    Barroso, Mário; Moreno, Ivo; da Fonseca, Beatriz; Queiroz, João António; Gallardo, Eugenia

    2012-07-01

    The last two decades have provided analysts with more sensitive technology, enabling scientists from all analytical fields to see what they were not able to see just a few years ago. This increased sensitivity has allowed drug detection at very low concentrations and testing in unconventional samples (e.g., hair, oral fluid and sweat), where despite having low analyte concentrations has also led to a reduction in sample size. Along with this reduction, and as a result of the use of excessive amounts of potentially toxic organic solvents (with the subsequent environmental pollution and costs associated with their proper disposal), there has been a growing tendency to use miniaturized sampling techniques. Those sampling procedures allow reducing organic solvent consumption to a minimum and at the same time provide a rapid, simple and cost-effective approach. In addition, it is possible to get at least some degree of automation when using these techniques, which will enhance sample throughput. Those miniaturized sample preparation techniques may be roughly categorized in solid-phase and liquid-phase microextraction, depending on the nature of the analyte. This paper reviews recently published literature on the use of microextraction sampling procedures, with a special focus on the field of forensic toxicology.

  8. Marine sediment sample pre-processing for macroinvertebrates metabarcoding: mechanical enrichment and homogenization

    Directory of Open Access Journals (Sweden)

    Eva Aylagas

    2016-10-01

    Full Text Available Metabarcoding is an accurate and cost-effective technique that allows for simultaneous taxonomic identification of multiple environmental samples. Application of this technique to marine benthic macroinvertebrate biodiversity assessment for biomonitoring purposes requires standardization of laboratory and data analysis procedures. In this context, protocols for creation and sequencing of amplicon libraries and their related bioinformatics analysis have been recently published. However, a standardized protocol describing all previous steps (i.e. processing and manipulation of environmental samples for macroinvertebrate community characterization is lacking. Here, we provide detailed procedures for benthic environmental sample collection, processing, enrichment for macroinvertebrates, homogenization, and subsequent DNA extraction for metabarcoding analysis. Since this is the first protocol of this kind, it should be of use to any researcher in this field, having the potential for improvement.

  9. ISOLOK VALVE ACCEPTANCE TESTING FOR DWPF SME SAMPLING PROCESS

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, T.; Hera, K.; Coleman, C.; Jones, M.; Wiedenman, B.

    2011-12-05

    the two locations were compared to determine if the contents of the tank were well mixed. The Coliwasa sampler is a tube with a stopper at the bottom and is designed to obtain grab samples from specific locations within the drum contents. A position paper (4) was issued to address the prototypic flow loop issues and simulant selections. A statistically designed plan (5) was issued to address the total number of samples each sampler needed to pull, to provide the random order in which samples were pulled and to group samples for elemental analysis. The TTR required that the Isolok sampler perform as well as the Hydragard sampler during these tests to ensure the acceptability of the Isolok sampler for use in the DWPF sampling cells. Procedure No.L9.4-5015 was used to document the sample parameters and process steps. Completed procedures are located in R&D Engineering job folder 23269.

  10. Acceptance test procedure for core sample trucks

    International Nuclear Information System (INIS)

    Smalley, J.L.

    1995-01-01

    The purpose of this Acceptance Test Procedure is to provide instruction and documentation for acceptance testing of the rotary mode core sample trucks, HO-68K-4600 and HO-68K-4647. The rotary mode core sample trucks were based upon the design of the second core sample truck (HO-68K-4345) which was constructed to implement rotary mode sampling of the waste tanks at Hanford. Acceptance testing of the rotary mode core sample trucks will verify that the design requirements have been met. All testing will be non-radioactive and stand-in materials shall be used to simulate waste tank conditions. Compressed air will be substituted for nitrogen during the majority of testing, with nitrogen being used only for flow characterization

  11. Secondary School Students' Reasoning about Conditional Probability, Samples, and Sampling Procedures

    Science.gov (United States)

    Prodromou, Theodosia

    2016-01-01

    In the Australian mathematics curriculum, Year 12 students (aged 16-17) are asked to solve conditional probability problems that involve the representation of the problem situation with two-way tables or three-dimensional diagrams and consider sampling procedures that result in different correct answers. In a small exploratory study, we…

  12. Inverse sampled Bernoulli (ISB) procedure for estimating a population proportion, with nuclear material applications

    International Nuclear Information System (INIS)

    Wright, T.

    1982-01-01

    A new sampling procedure is introduced for estimating a population proportion. The procedure combines the ideas of inverse binomial sampling and Bernoulli sampling. An unbiased estimator is given with its variance. The procedure can be viewed as a generalization of inverse binomial sampling

  13. Procedure for determination of alpha emitters in urine and dregs samples

    International Nuclear Information System (INIS)

    Serdeiro, Nelida H.

    2005-01-01

    The purpose of this work is to establish the procedure for the identification and quantification of emitting alpha radionuclides in urine and dregs samples. This procedure are applied to all laboratories of the countries of the Project ARCAL LXXVII that determinate alpha emitting radionuclides in biological samples for biological assessment [es

  14. Partial report and other sampling procedures overestimate the duration of iconic memory.

    Science.gov (United States)

    Appelman, I B

    1980-03-01

    In three experiments, subjects estimated the duration of a brief visual image (iconic memory) either directly by adjusting onset of a click to offset of the visual image, or indirectly with a Sperling partial report (sampling) procedure. The results indicated that partial report and other sampling procedures may reflect other brief phenomena along with iconic memory. First, the partial report procedure yields a greater estimate of the duration of iconic memory than the more direct click method. Second, the partial report estimate of the duration of iconic memory is affected if the subject is required to simultaneously retain a list of distractor items (memory load), while the click method estimate of the duration of iconic memory is not affected by a memory load. Finally, another sampling procedure based on visual cuing yields different estimates of the duration of iconic memory depending on how many items are cued. It was concluded that partial report and other sampling procedures overestimate the duration of iconic memory.

  15. The Alaska Commercial Fisheries Water Quality Sampling Methods and Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Folley, G.; Pearson, L.; Crosby, C. [Alaska Dept. of Environmental Conservation, Soldotna, AK (United States); DeCola, E.; Robertson, T. [Nuka Research and Planning Group, Seldovia, AK (United States)

    2006-07-01

    A comprehensive water quality sampling program was conducted in response to the oil spill that occurred when the M/V Selendang Ayu ship ran aground near a major fishing port at Unalaska Island, Alaska in December 2004. In particular, the sampling program focused on the threat of spilled oil to the local commercial fisheries resources. Spill scientists were unable to confidently model the movement of oil away from the wreck because of limited oceanographic data. In order to determine which fish species were at risk of oil contamination, a real-time assessment of how and where the oil was moving was needed, because the wreck became a continual source of oil release for several weeks after the initial grounding. The newly developed methods and procedures used to detect whole oil during the sampling program will be presented in the Alaska Commercial Fisheries Water Quality Sampling Methods and Procedures Manual which is currently under development. The purpose of the manual is to provide instructions to spill managers while they try to determine where spilled oil has or has not been encountered. The manual will include a meaningful data set that can be analyzed in real time to assess oil movement and concentration. Sections on oil properties and processes will be included along with scientific water quality sampling methods for whole and dissolved phase oil to assess potential contamination of commercial fishery resources and gear in Alaska waters during an oil spill. The manual will present a general discussion of factors that should be considered when designing a sampling program after a spill. In order to implement Alaska's improved seafood safety measures, the spatial scope of spilled oil must be known. A water quality sampling program can provide state and federal fishery managers and food safety inspectors with important information as they identify at-risk fisheries. 11 refs., 7 figs.

  16. Development of a simple extraction procedure for chlorpyrifos determination in food samples by immunoassay.

    Science.gov (United States)

    Gabaldón, J A; Maquieira, A; Puchades, R

    2007-02-28

    The suitability of immunoassay methodology for rapid and accurate determination of chlorpyrifos in vegetables was tested. The optimised ELISA detection limit was 0.32ng/ml, with a working range from 0.69 to 6.21ng/ml and an immunoassay test-mid point (IC(50)) of 2.08ng/ml. A rapid sample preparation procedure considering different parameters such as the amount of sample, volume of extractant, extraction time and dilution factor was optimised. The developed direct extraction (DE) and multiresidue (ME) standard procedures were performed in different fortified fresh and processed vegetable samples (tomato, bonnet pepper, bean, pea, asparagus, broccoli, watermelon, melon, lettuce, cucumber, celery and red pepper). Recoveries were in all cases in the whole range 85.2-108.9% for both DE and ME extracts. Also, the comparison of the results obtained by both immunochemical and chromatographic methods for spiked fruits and vegetables were good with a correlation coefficient (r) of 0.97.

  17. Sampling and sample handling procedures for priority pollutants in surface coal mining wastewaters. [Detailed list to be analyzed for

    Energy Technology Data Exchange (ETDEWEB)

    Hayden, R. S.; Johnson, D. O.; Henricks, J. D.

    1979-03-01

    The report describes the procedures used by Argonne National Laboratory to sample surface coal mine effluents in order to obtain field and laboratory data on 110 organic compounds or classes of compounds and 14 metals and minerals that are known as priority pollutants, plus 5-day biochemical oxygen demand (BOD/sub 5/), total organic carbon (TOC), chemical oxygen demand (COD), total dissolved solids (TDS), and total suspended solids (TSS). Included are directions for preparation of sampling containers and equipment, methods of sampling and sample preservation, and field and laboratory protocols, including chain-of-custody procedures. Actual analytical procedures are not described, but their sources are referenced.

  18. 19 CFR 181.33 - Customs processing procedures.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Customs processing procedures. 181.33 Section 181.33 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF....33 Customs processing procedures. (a) Status determination. After receipt of a post-importation claim...

  19. Procedures for sampling and sample reduction within quality assurance systems for solid biofuels

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    The objective of this experimental study on sampling was to determine the size and number of samples of biofuels required (taken at two sampling points in each case) and to compare two methods of sampling. The first objective of the sample-reduction exercise was to compare the reliability of various sampling methods, and the second objective was to measure the variations introduced as a result of reducing the sample size to form suitable test portions. The materials studied were sawdust, wood chips, wood pellets and bales of straw, and these were analysed for moisture, ash, particle size and chloride. The sampling procedures are described. The study was conducted in Scandinavia. The results of the study were presented in Leipzig in October 2004. The work was carried out as part of the UK's DTI Technology Programme: New and Renewable Energy.

  20. Sampling Strategies and Processing of Biobank Tissue Samples from Porcine Biomedical Models.

    Science.gov (United States)

    Blutke, Andreas; Wanke, Rüdiger

    2018-03-06

    In translational medical research, porcine models have steadily become more popular. Considering the high value of individual animals, particularly of genetically modified pig models, and the often-limited number of available animals of these models, establishment of (biobank) collections of adequately processed tissue samples suited for a broad spectrum of subsequent analyses methods, including analyses not specified at the time point of sampling, represent meaningful approaches to take full advantage of the translational value of the model. With respect to the peculiarities of porcine anatomy, comprehensive guidelines have recently been established for standardized generation of representative, high-quality samples from different porcine organs and tissues. These guidelines are essential prerequisites for the reproducibility of results and their comparability between different studies and investigators. The recording of basic data, such as organ weights and volumes, the determination of the sampling locations and of the numbers of tissue samples to be generated, as well as their orientation, size, processing and trimming directions, are relevant factors determining the generalizability and usability of the specimen for molecular, qualitative, and quantitative morphological analyses. Here, an illustrative, practical, step-by-step demonstration of the most important techniques for generation of representative, multi-purpose biobank specimen from porcine tissues is presented. The methods described here include determination of organ/tissue volumes and densities, the application of a volume-weighted systematic random sampling procedure for parenchymal organs by point-counting, determination of the extent of tissue shrinkage related to histological embedding of samples, and generation of randomly oriented samples for quantitative stereological analyses, such as isotropic uniform random (IUR) sections generated by the "Orientator" and "Isector" methods, and vertical

  1. Research And Establishment Of The Analytical Procedure For/Of Sr-90 In Milk Samples

    International Nuclear Information System (INIS)

    Tran Thi Tuyet Mai; Duong Duc Thang; Nguyen Thi Linh; Bui Thi Anh Duong

    2014-01-01

    Sr-90 is an indicator for the transfer radionuclides from environment to human. This work was setup to build a procedure for Sr-90 determination in main popular foodstuff and focus to fresh milk. The deal of this work was establish procedure for Sr-90 , assessment for chemical yield and test sample of Vietnam fresh milk, also in this work, the QA, QC for the procedure was carried out using standard sample of IAEA. The work has been completed for the procedure of determination Sr-90 in milk. The chemical yield of recovery for Y-90 and Sr-90 were at 46.76 % ±1.25% and 0.78 ± 0.086, respectively. The QA & QC program was carried out using reference material IAEA-373. The result parse is appropriate equally and well agreement with the certificate value. Three reference samples were analyses with 15 measurements. The results of Sr-90 concentration after processing statistics given a value at 3.69 Bq/kg with uncertainty of 0.23 Bq/kg. The certificate of IAEA-154 for Sr-90 (half live 28.8 year) is the 6.9 Bq/kg, with the range 95% Confidence Interval as (6.0 -8.0 ) Bq/kg at 31st August 1987. After adjusting decay, the radioactivity at this time is 3.67 Bq/kg. It means that such the result of this work was perfect matching the value of stock index IAEA. Five Vietnam fresh milk samples were analyzed for Sr-90, the specific radioactivity of Sr-90 in milk were in a range from 0.032 to 0.041 Bq/l. (author)

  2. Procedural Due Process Rights in Student Discipline.

    Science.gov (United States)

    Pressman, Robert; Weinstein, Susan

    To assist administrators in understanding procedural due process rights in student discipline, this manual draws together hundreds of citations and case summaries of federal and state court decisions and provides detailed commentary as well. Chapter 1 outlines the general principles of procedural due process rights in student discipline, such as…

  3. Procedure manual for the estimation of average indoor radon-daughter concentrations using the radon grab-sampling method

    International Nuclear Information System (INIS)

    George, J.L.

    1986-04-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center to provide standardization, calibration, comparability, verification of data, quality assurance, and cost-effectiveness for the measurement requirements of DOE remedial action programs. One of the remedial-action measurement needs is the estimation of average indoor radon-daughter concentration. One method for accomplishing such estimations in support of DOE remedial action programs is the radon grab-sampling method. This manual describes procedures for radon grab sampling, with the application specifically directed to the estimation of average indoor radon-daughter concentration (RDC) in highly ventilated structures. This particular application of the measurement method is for cases where RDC estimates derived from long-term integrated measurements under occupied conditions are below the standard and where the structure being evaluated is considered to be highly ventilated. The radon grab-sampling method requires that sampling be conducted under standard maximized conditions. Briefly, the procedure for radon grab sampling involves the following steps: selection of sampling and counting equipment; sample acquisition and processing, including data reduction; calibration of equipment, including provisions to correct for pressure effects when sampling at various elevations; and incorporation of quality-control and assurance measures. This manual describes each of the above steps in detail and presents an example of a step-by-step radon grab-sampling procedure using a scintillation cell

  4. Sampling procedures for inventory of commercial volume tree species in Amazon Forest.

    Science.gov (United States)

    Netto, Sylvio P; Pelissari, Allan L; Cysneiros, Vinicius C; Bonazza, Marcelo; Sanquetta, Carlos R

    2017-01-01

    The spatial distribution of tropical tree species can affect the consistency of the estimators in commercial forest inventories, therefore, appropriate sampling procedures are required to survey species with different spatial patterns in the Amazon Forest. For this, the present study aims to evaluate the conventional sampling procedures and introduce the adaptive cluster sampling for volumetric inventories of Amazonian tree species, considering the hypotheses that the density, the spatial distribution and the zero-plots affect the consistency of the estimators, and that the adaptive cluster sampling allows to obtain more accurate volumetric estimation. We use data from a census carried out in Jamari National Forest, Brazil, where trees with diameters equal to or higher than 40 cm were measured in 1,355 plots. Species with different spatial patterns were selected and sampled with simple random sampling, systematic sampling, linear cluster sampling and adaptive cluster sampling, whereby the accuracy of the volumetric estimation and presence of zero-plots were evaluated. The sampling procedures applied to species were affected by the low density of trees and the large number of zero-plots, wherein the adaptive clusters allowed concentrating the sampling effort in plots with trees and, thus, agglutinating more representative samples to estimate the commercial volume.

  5. Delineating sampling procedures: Pedagogical significance of analysing sampling descriptions and their justifications in TESL experimental research reports

    Directory of Open Access Journals (Sweden)

    Jason Miin-Hwa Lim

    2011-04-01

    Full Text Available Teaching second language learners how to write research reports constitutes a crucial component in programmes on English for Specific Purposes (ESP in institutions of higher learning. One of the rhetorical segments in research reports that merit attention has to do with the descriptions and justifications of sampling procedures. This genre-based study looks into sampling delineations in the Method-related sections of research articles on the teaching of English as a second language (TESL written by expert writers and published in eight reputed international refereed journals. Using Swales’s (1990 & 2004 framework, I conducted a quantitative analysis of the rhetorical steps and a qualitative investigation into the language resources employed in delineating sampling procedures. This investigation has considerable relevance to ESP students and instructors as it has yielded pertinent findings on how samples can be appropriately described to meet the expectations of dissertation examiners, reviewers, and supervisors. The findings of this study have furnished insights into how supervisors and instructors can possibly teach novice writers ways of using specific linguistic mechanisms to lucidly describe and convincingly justify the sampling procedures in the Method sections of experimental research reports.

  6. A random sampling procedure for anisotropic distributions

    International Nuclear Information System (INIS)

    Nagrajan, P.S.; Sethulakshmi, P.; Raghavendran, C.P.; Bhatia, D.P.

    1975-01-01

    A procedure is described for sampling the scattering angle of neutrons as per specified angular distribution data. The cosine of the scattering angle is written as a double Legendre expansion in the incident neutron energy and a random number. The coefficients of the expansion are given for C, N, O, Si, Ca, Fe and Pb and these elements are of interest in dosimetry and shielding. (author)

  7. Sampling, storage and sample preparation procedures for X ray fluorescence analysis of environmental materials

    International Nuclear Information System (INIS)

    1997-06-01

    X ray fluorescence (XRF) method is one of the most commonly used nuclear analytical technique because of its multielement and non-destructive character, speed, economy and ease of operation. From the point of view of quality assurance practices, sampling and sample preparation procedures are the most crucial steps in all analytical techniques, (including X ray fluorescence) applied for the analysis of heterogeneous materials. This technical document covers recent modes of the X ray fluorescence method and recent developments in sample preparation techniques for the analysis of environmental materials. Refs, figs, tabs

  8. Sampling and sample processing in pesticide residue analysis.

    Science.gov (United States)

    Lehotay, Steven J; Cook, Jo Marie

    2015-05-13

    Proper sampling and sample processing in pesticide residue analysis of food and soil have always been essential to obtain accurate results, but the subject is becoming a greater concern as approximately 100 mg test portions are being analyzed with automated high-throughput analytical methods by agrochemical industry and contract laboratories. As global food trade and the importance of monitoring increase, the food industry and regulatory laboratories are also considering miniaturized high-throughput methods. In conjunction with a summary of the symposium "Residues in Food and Feed - Going from Macro to Micro: The Future of Sample Processing in Residue Analytical Methods" held at the 13th IUPAC International Congress of Pesticide Chemistry, this is an opportune time to review sampling theory and sample processing for pesticide residue analysis. If collected samples and test portions do not adequately represent the actual lot from which they came and provide meaningful results, then all costs, time, and efforts involved in implementing programs using sophisticated analytical instruments and techniques are wasted and can actually yield misleading results. This paper is designed to briefly review the often-neglected but crucial topic of sample collection and processing and put the issue into perspective for the future of pesticide residue analysis. It also emphasizes that analysts should demonstrate the validity of their sample processing approaches for the analytes/matrices of interest and encourages further studies on sampling and sample mass reduction to produce a test portion.

  9. Remarks on the sampling procedures for polycyclic aromatic hydrocarbons from the atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Tomingas, R [Duesseldorf Univ. (Germany, F.R.). Inst. fuer Lufthygiene und Silikoseforschung

    1979-01-01

    Despite all efforts to optimize the sampling procedure for polycyclic aromatic hydrocarbons (PAH) a part of the PAH is lost during the sampling period. The amount of loss depends on the vapour pressure, the air flow rate, the oxidants in the suspended matter and on the sampling time. The sampling time in return is determined by the PAH concentration in the atmosphere and cannot be shortened infinitely, at least not at the expense of the air flow rate. When the concentration of the PAH is extremely low, a repeated change of the filters is advisable. Losses of PAH even occur when filters are stored in the dark. An evaluation of these losses is difficult for many reasons. There is no relationship between the amount of loss and time unit; the decrease of each PAH is different and seems to depend on the composition of the particulate matter collected on the filter. The disappearance of the PAH from the filter is a continual process, therefore a rapid performance of the analysis is inevitable.

  10. 9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.

    Science.gov (United States)

    2010-01-01

    ... samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic... for diagnostic testing. (b) The authorized laboratory must identify each egg as to the breeding flock...

  11. Evaluation procedure for radioactive waste treatment processes

    International Nuclear Information System (INIS)

    Whitty, W.J.

    1979-11-01

    An aspect of the Los Alamos Scientific Laboratory's nuclear waste management R and D programs has been to develop an evaluation procedure for radioactive waste treatment processes. This report describes the process evaluation method. Process worth is expressed as a numerical index called the Figure-of-Merit (FOM), which is computed using a hierarchial, linear, additive, scoring model with constant criteria weights and nonlinear value functions. A numerical example is used to demonstrate the procedure and to point out some of its strengths and weaknesses. Potential modifications and extensions are discussed, and an extensive reference list is included

  12. 10 CFR 765.21 - Procedures for processing reimbursement claims.

    Science.gov (United States)

    2010-01-01

    ... Department shall complete a final review of all relevant information prior to making a reimbursement decision... 10 Energy 4 2010-01-01 2010-01-01 false Procedures for processing reimbursement claims. 765.21... AND THORIUM PROCESSING SITES Procedures for Submitting and Processing Reimbursement Claims § 765.21...

  13. On the assessment of extremely low breakdown probabilities by an inverse sampling procedure [gaseous insulation

    DEFF Research Database (Denmark)

    Thyregod, Poul; Vibholm, Svend

    1991-01-01

    the flashover probability function and the corresponding distribution of first breakdown voltages under the inverse sampling procedure, and show how this relation may be utilized to assess the single-shot flashover probability corresponding to the observed average first breakdown voltage. Since the procedure......First breakdown voltages obtained under the inverse sampling procedure assuming a double exponential flashover probability function are discussed. An inverse sampling procedure commences the voltage application at a very low level, followed by applications at stepwise increased levels until...... is based on voltage applications in the neighbourhood of the quantile under investigation, the procedure is found to be insensitive to the underlying distributional assumptions...

  14. Relations among conceptual knowledge, procedural knowledge, and procedural flexibility in two samples differing in prior knowledge.

    Science.gov (United States)

    Schneider, Michael; Rittle-Johnson, Bethany; Star, Jon R

    2011-11-01

    Competence in many domains rests on children developing conceptual and procedural knowledge, as well as procedural flexibility. However, research on the developmental relations between these different types of knowledge has yielded unclear results, in part because little attention has been paid to the validity of the measures or to the effects of prior knowledge on the relations. To overcome these problems, we modeled the three constructs in the domain of equation solving as latent factors and tested (a) whether the predictive relations between conceptual and procedural knowledge were bidirectional, (b) whether these interrelations were moderated by prior knowledge, and (c) how both constructs contributed to procedural flexibility. We analyzed data from 2 measurement points each from two samples (Ns = 228 and 304) of middle school students who differed in prior knowledge. Conceptual and procedural knowledge had stable bidirectional relations that were not moderated by prior knowledge. Both kinds of knowledge contributed independently to procedural flexibility. The results demonstrate how changes in complex knowledge structures contribute to competence development.

  15. Comparison of two sample preparation procedures for HPLC determination of ochratoxin A

    Directory of Open Access Journals (Sweden)

    Vuković Gorica L.

    2009-01-01

    Full Text Available In preparation of samples for chromatographic determination of ochratoxin A, two types of columns were used for sample cleanup (SPE and immunoaffinity columns. The first method consisted of liquid-liquid extraction with a mixture of chloroform and phosphoric acid, followed by ion-exchange cleanup on Waters Oasis MAX columns. The sec­ond method consisted of extraction with a mixture of water and methanol, followed by LCTech OtaCLEAN immunoaf­finity column cleanup. Recoveries of the methods were determined at three levels in three repetitions for maize flour, and they were 84% (%RSD = 19.2 for the first method of sample preparation and 101% (%RSD = 2.2 for the second method. Values of LOQ for OTA were 0.25 and 1.00 μg/kg for the IAC and SPE clean-up procedures, respectively. Both methods comply with present regulations, but the MAX sample clean-up procedure should be used as an alternative, since the immunoaffinity column clean-up procedure is characterized by better reproducibility, accuracy, and efficiency.

  16. Guidelines for the processing and quality assurance of benthic invertebrate samples collected as part of the National Water-Quality Assessment Program

    Science.gov (United States)

    Cuffney, T.F.; Gurtz, M.E.; Meador, M.R.

    1993-01-01

    Benthic invertebrate samples are collected as part of the U.S. Geological Survey's National Water-Quality Assessment Program. This is a perennial, multidisciplinary program that integrates biological, physical, and chemical indicators of water quality to evaluate status and trends and to develop an understanding of the factors controlling observed water quality. The Program examines water quality in 60 study units (coupled ground- and surface-water systems) that encompass most of the conterminous United States and parts of Alaska and Hawaii. Study-unit teams collect and process qualitative and semi-quantitative invertebrate samples according to standardized procedures. These samples are processed (elutriated and subsampled) in the field to produce as many as four sample components: large-rare, main-body, elutriate, and split. Each sample component is preserved in 10-percent formalin, and two components, large-rare and main-body, are sent to contract laboratories for further processing. The large-rare component is composed of large invertebrates that are removed from the sample matrix during field processing and placed in one or more containers. The main-body sample component consists of the remaining sample materials (sediment, detritus, and invertebrates) and is subsampled in the field to achieve a volume of 750 milliliters or less. The remaining two sample components, elutriate and split, are used for quality-assurance and quality-control purposes. Contract laboratories are used to identify and quantify invertebrates from the large-rare and main-body sample components according to the procedures and guidelines specified within this document. These guidelines allow the use of subsampling techniques to reduce the volume of sample material processed and to facilitate identifications. These processing procedures and techniques may be modified if the modifications provide equal or greater levels of accuracy and precision. The intent of sample processing is to

  17. Establishing a routine procedure for extraction of water from vegetation samples

    International Nuclear Information System (INIS)

    Varlam, Carmen; Stefanescu, Ioan; Faurescu, Ionut; Vagner, Irina; Faurescu, Denisa

    2008-01-01

    Full text: The Cryogenic Pilot is an experimental project within the nuclear energy national research program, which has the aim of developing technologies for tritium and deuterium separation by cryogenic distillation. The process, used in this installation, is based on a combined method for liquid-phase catalytic exchange (LPCE) and cryogenic distillation. There are two ways that Cryogenic Pilot can interact with the environment: by atmospheric release and by sewage. In order to establish the base line of tritium concentration in the environment around the nuclear facilities we investigated the preparation procedure for different type of samples: soil, hay, apple, grass, milk, meat and water. For azeotropic distillation of all types of samples two solvents were used, toluene and cyclohexane, and all measurements for determination of environmental tritium concentration were carry out using liquid scintillation counting (LSC), with ultra-low level liquid scintillation spectrometer Quantulus 1220 specially designed for environmental samples and low radioactivity. Sample scintillation cocktail ratio was 8:12 ml and liquid scintillation cocktail was UltimaGold LLT. The background determined for control samples prepared ranged between 0.926 Cpm and 1.002 Cpm and counting efficiency between 25.3% and 26.1%. The counting time was 1000 minutes (50 minutes/20 cycles) for each sample, and minimum detectable activity according to ISO 9698 was 8.9 TU, and 9.05 TU, respectively, with a confidence coefficient of 3. (authors)

  18. 7 CFR 52.38c - Statistical sampling procedures for lot inspection of processed fruits and vegetables by attributes.

    Science.gov (United States)

    2010-01-01

    ... FRUITS AND VEGETABLES, PROCESSED PRODUCTS THEREOF, AND CERTAIN OTHER PROCESSED FOOD PRODUCTS 1... processed fruits and vegetables by attributes. 52.38c Section 52.38c Agriculture Regulations of the... inspection of processed fruits and vegetables by attributes. (a) General. Single sampling plans shall be used...

  19. Study on auto-plating process time versus recovery for polonium, Po-210 in environmental sample

    International Nuclear Information System (INIS)

    Jalal Sharib; Zaharudin Ahmad; Abdul Kadir Ishak; Norfaizal Mohamed; Ahmad Sanadi Abu Bakar; Yii Mei Wo; Kamarozaman Ishak; Siti Aminah Yusoff

    2008-08-01

    This study was carried out to evaluate time effectiveness and recovery 16 samples of 4 Kuala Muda stations during auto-plating process procedures for determination Polonium, Po 210 activity concentration in environmental sample. The study was performed using Kuala Muda sediment as sample in the same methodology. The auto-plating process runs for 4, 12, 24 and 30 hours on a silver disc for 4 samples each station, and then counted for one (1) day using an alpha spectrometry counting system. The objectives for this study is to justify on time duration for auto-plating process effecting a chemical yield of Po-209.The results showed recovery are increasing versus time and constantly at 24 hour auto-plating. Its mean, 24 hour is an optimum time for auto-plating process for determination of Polonium, Po 210 activity concentration in environmental sample. (Author)

  20. A method for disaggregating clay concretions and eliminating formalin smell in the processing of sediment samples

    DEFF Research Database (Denmark)

    Cedhagen, Tomas

    1989-01-01

    A complete handling procedure for processing sediment samples is described. It includes some improvements of conventional methods. The fixed sediment sample is mixed with a solution of the alkaline detergent AJAX® (Colgate-Palmolive). It is kept at 80-900 C for 20-40 min. This treatment facilitates...

  1. Scientific information processing procedures

    Directory of Open Access Journals (Sweden)

    García, Maylin

    2013-07-01

    Full Text Available The paper systematizes several theoretical view-points on scientific information processing skill. It decomposes the processing skills into sub-skills. Several methods such analysis, synthesis, induction, deduction, document analysis were used to build up a theoretical framework. Interviews and survey to professional being trained and a case study was carried out to evaluate the results. All professional in the sample improved their performance in scientific information processing.

  2. A comparative examination of sample treatment procedures for ICAP-AES analysis of biological tissue

    Science.gov (United States)

    De Boer, J. L. M.; Maessen, F. J. M. J.

    The objective of this study was to contribute to the evaluation of existing sample preparation procedures for ICAP-AES analysis of biological material. Performance characteristics were established of current digestion procedures comprising extraction, solubilization, pressure digestion, and wet and dry ashing methods. Apart from accuracy and precision, a number of criteria of special interest for the analytical practice was applied. As a test sample served SRM bovine liver. In this material six elements were simultaneously determined. Results showed that every procedure has its defects and advantages. Hence, unambiguous recommendation of standard digestion procedures can be made only when taking into account the specific analytical problem.

  3. A review of blood sample handling and pre-processing for metabolomics studies.

    Science.gov (United States)

    Hernandes, Vinicius Veri; Barbas, Coral; Dudzik, Danuta

    2017-09-01

    Metabolomics has been found to be applicable to a wide range of clinical studies, bringing a new era for improving clinical diagnostics, early disease detection, therapy prediction and treatment efficiency monitoring. A major challenge in metabolomics, particularly untargeted studies, is the extremely diverse and complex nature of biological specimens. Despite great advances in the field there still exist fundamental needs for considering pre-analytical variability that can introduce bias to the subsequent analytical process and decrease the reliability of the results and moreover confound final research outcomes. Many researchers are mainly focused on the instrumental aspects of the biomarker discovery process, and sample related variables sometimes seem to be overlooked. To bridge the gap, critical information and standardized protocols regarding experimental design and sample handling and pre-processing are highly desired. Characterization of a range variation among sample collection methods is necessary to prevent results misinterpretation and to ensure that observed differences are not due to an experimental bias caused by inconsistencies in sample processing. Herein, a systematic discussion of pre-analytical variables affecting metabolomics studies based on blood derived samples is performed. Furthermore, we provide a set of recommendations concerning experimental design, collection, pre-processing procedures and storage conditions as a practical review that can guide and serve for the standardization of protocols and reduction of undesirable variation. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Analytical procedures for determining Pb and Sr isotopic compositions in water samples by ID-TIMS

    Directory of Open Access Journals (Sweden)

    Veridiana Martins

    2008-01-01

    Full Text Available Few articles deal with lead and strontium isotopic analysis of water samples. The aim of this study was to define the chemical procedures for Pb and Sr isotopic analyses of groundwater samples from an urban sedimentary aquifer. Thirty lead and fourteen strontium isotopic analyses were performed to test different analytical procedures. Pb and Sr isotopic ratios as well as Sr concentration did not vary using different chemical procedures. However, the Pb concentrations were very dependent on the different procedures. Therefore, the choice of the best analytical procedure was based on the Pb results, which indicated a higher reproducibility from samples that had been filtered and acidified before the evaporation, had their residues totally dissolved, and were purified by ion chromatography using the Biorad® column. Our results showed no changes in Pb ratios with the storage time.

  5. Comparison of sample preparation procedures on metal(loid) fractionation patterns in lichens.

    Science.gov (United States)

    Kroukamp, E M; Godeto, T W; Forbes, P B C

    2017-08-13

    The effects of different sample preparation strategies and storage on metal(loid) fractionation trends in plant material is largely underresearched. In this study, a bulk sample of lichen Parmotrema austrosinense (Zahlbr.) Hale was analysed for its total extractable metal(loid) content by ICP-MS, and was determined to be adequately homogenous (sample were prepared utilising a range of sample preservation techniques and subjected to a modified sequential extraction procedure or to total metal extraction. Both experiments were repeated after 1-month storage at 4 °C. Cryogenic freezing gave the best reproducibility for total extractable elemental concentrations between months, indicating this to be the most suitable method of sample preparation in such studies. The combined extraction efficiencies were >82% for As, Cu, Mn, Pb, Sr and Zn but poor for other elements, where sample preparation strategies 'no sample preparation' and 'dried in a desiccator' had the best extraction recoveries. Cryogenic freezing procedures had a significantly (p sample cleaning and preservation when species fractionation patterns are of interest. This study also shows that the assumption that species stability can be ensured through cryopreservation and freeze drying techniques needs to be revisited.

  6. Development of Radioanalytical and Microanalytical Procedures for the Determination of Actinides in Environmental Samples

    International Nuclear Information System (INIS)

    Macsik, Zsuzsanna; Vajda, Nora; Bene, Balazs; Varga, Zsolt

    2008-01-01

    A radio-analytical procedure has been developed for the simultaneous determination of actinides in swipe samples by alpha-spectrometry after the separation of the actinides by extraction chromatography. The procedure is based on the complete decomposition of the sample by destruction with microwave digestion or ashing in furnace. Actinides are separated on an extraction chromatographic column filled with TRU resin (product of Eichrom Industries Inc.). Alpha sources prepared from the separated fractions of americium, plutonium, thorium and uranium are counted by alpha spectrometry. Micro-analytical procedure is being developed for the location and identification of individual particles containing fissile material using solid state nuclear track detectors. The parameters of alpha and fission track detection have been optimized and a procedure has been elaborated to locate the particles on the sample by defining the coordinates of the tracks created by the particles on the track detector. Development of a procedure is planned to separate the located particles using micromanipulator and these particles will be examined individually by different micro- and radio-analytical techniques. (authors)

  7. Development of Radioanalytical and Microanalytical Procedures for the Determination of Actinides in Environmental Samples

    Energy Technology Data Exchange (ETDEWEB)

    Macsik, Zsuzsanna [Institute of Nuclear Techniques, Moegyetem rakpart 9, H-1111 Budapest (Hungary); Vajda, Nora [RadAnal Ltd., Bimbo ut 119/a, H-1026 Budapest (Hungary); Bene, Balazs [National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Varga, Zsolt [Institute of Isotopes, Konkoly-Thege M. ut 29-33, H-1121 Budapest (Hungary)

    2008-07-01

    A radio-analytical procedure has been developed for the simultaneous determination of actinides in swipe samples by alpha-spectrometry after the separation of the actinides by extraction chromatography. The procedure is based on the complete decomposition of the sample by destruction with microwave digestion or ashing in furnace. Actinides are separated on an extraction chromatographic column filled with TRU resin (product of Eichrom Industries Inc.). Alpha sources prepared from the separated fractions of americium, plutonium, thorium and uranium are counted by alpha spectrometry. Micro-analytical procedure is being developed for the location and identification of individual particles containing fissile material using solid state nuclear track detectors. The parameters of alpha and fission track detection have been optimized and a procedure has been elaborated to locate the particles on the sample by defining the coordinates of the tracks created by the particles on the track detector. Development of a procedure is planned to separate the located particles using micromanipulator and these particles will be examined individually by different micro- and radio-analytical techniques. (authors)

  8. Influence of different processing procedures on the reproductive capacity of Trichinella spiralis in pork meat.

    Science.gov (United States)

    Medina-Lerena, M S; Ramirez-Alvarez, A; Kühne, M; Gómez-Priego, A; de-la-Rosa, J-L

    2009-04-01

    The aim of this work was to determine the influence of different processing procedures and preparations on the viability and infectivity of Trichinella spiralis ML. The muscles of limbs tongue and masseters of pigs experimentally infected were collected, splitted to pieces, and pooled. Five batches were used for the following processing procedures: (1) seasoning with "adobo", commercially acquired chilli and several other spices, (2) "wet-curing" by immersion of meat pieces in 3% brine during 24 hours, (3) cold storage without any further processing or preparation, (4) freezing to -20 degrees C and, (5) drying for 24 hours at 60 degrees C. Samples were stored at 4 degrees C for 15, 45, 60, 75, 90, 105 or 266 days after preparation. At the last-mentioned dates, ML were recovered and used to determine the reproductive capacity by infecting naïve mice. The state of meat conservation or spoilage respectively was tested by visual and tactile examination. In samples treated by freezing or drying no motile larvae were found after artificial digestion and, following inoculation of mice with larvae recovered from these groups, no ML were founded after 40 days of infection. After the artificial digestion of the cold stored samples, the ones seasoned with "adobo" and "wet-cured", a number of motile ML were consistently obtained. Initial reproductive capacity index was as of 80+/-0.5, then rates decreased to 60 - 70 between days 15 and 105 PT and dropped to 40+/-6.7 at day 266 for seasoned, 33+/-2.7 for cold-stored and 33+/-2.5 for cured samples. The influence of storage time (p=0.000005; factorial ANOVA) but not for processing procedure (p=0.724; factorial ANOVA) were statistically significant. The sensorial examination of the meat samples showed severe changes caused by spoilage in odour, texture and colour from day 45 of storage. Data reported from this trial proves that curing or flavoring do not inactivate the Trichinella Mexican strain, although cold storage for more

  9. Pierre Gy's sampling theory and sampling practice heterogeneity, sampling correctness, and statistical process control

    CERN Document Server

    Pitard, Francis F

    1993-01-01

    Pierre Gy's Sampling Theory and Sampling Practice, Second Edition is a concise, step-by-step guide for process variability management and methods. Updated and expanded, this new edition provides a comprehensive study of heterogeneity, covering the basic principles of sampling theory and its various applications. It presents many practical examples to allow readers to select appropriate sampling protocols and assess the validity of sampling protocols from others. The variability of dynamic process streams using variography is discussed to help bridge sampling theory with statistical process control. Many descriptions of good sampling devices, as well as descriptions of poor ones, are featured to educate readers on what to look for when purchasing sampling systems. The book uses its accessible, tutorial style to focus on professional selection and use of methods. The book will be a valuable guide for mineral processing engineers; metallurgists; geologists; miners; chemists; environmental scientists; and practit...

  10. Microstructure based procedure for process parameter control in rolling of aluminum thin foils

    Science.gov (United States)

    Johannes, Kronsteiner; Kabliman, Evgeniya; Klimek, Philipp-Christoph

    2018-05-01

    In present work, a microstructure based procedure is used for a numerical prediction of strength properties for Al-Mg-Sc thin foils during a hot rolling process. For this purpose, the following techniques were developed and implemented. At first, a toolkit for a numerical analysis of experimental stress-strain curves obtained during a hot compression testing by a deformation dilatometer was developed. The implemented techniques allow for the correction of a temperature increase in samples due to adiabatic heating and for the determination of a yield strength needed for the separation of the elastic and plastic deformation regimes during numerical simulation of multi-pass hot rolling. At the next step, an asymmetric Hot Rolling Simulator (adjustable table inlet/outlet height as well as separate roll infeed) was developed in order to match the exact processing conditions of a semi-industrial rolling procedure. At each element of a finite element mesh the total strength is calculated by in-house Flow Stress Model based on evolution of mean dislocation density. The strength values obtained by numerical modelling were found in a reasonable agreement with results of tensile tests for thin Al-Mg-Sc foils. Thus, the proposed simulation procedure might allow to optimize the processing parameters with respect to the microstructure development.

  11. Application of statistical process control and process capability analysis procedures in orbiter processing activities at the Kennedy Space Center

    Science.gov (United States)

    Safford, Robert R.; Jackson, Andrew E.; Swart, William W.; Barth, Timothy S.

    1994-01-01

    Successful ground processing at KSC requires that flight hardware and ground support equipment conform to specifications at tens of thousands of checkpoints. Knowledge of conformance is an essential requirement for launch. That knowledge of conformance at every requisite point does not, however, enable identification of past problems with equipment, or potential problem areas. This paper describes how the introduction of Statistical Process Control and Process Capability Analysis identification procedures into existing shuttle processing procedures can enable identification of potential problem areas and candidates for improvements to increase processing performance measures. Results of a case study describing application of the analysis procedures to Thermal Protection System processing are used to illustrate the benefits of the approaches described in the paper.

  12. Comparison of VFA titration procedures used for monitoring the biogas process

    DEFF Research Database (Denmark)

    Lützhøft, Hans-Christian Holten; Boe, Kanokwan; Fang, Cheng

    2014-01-01

    (GC) analysis. Two of the procedures are commonly used in biogas plants and two are discussed in literature. The results showed that the optimal titration results were obtained when 40mL of four times diluted digested manure was gently stirred (200rpm). Results from samples with different VFA......Titrimetric determination of volatile fatty acids (VFAs) contents is a common way to monitor a biogas process. However, digested manure from co-digestion biogas plants has a complex matrix with high concentrations of interfering components, resulting in varying results when using different...

  13. Configural and component processing in simultaneous and sequential lineup procedures.

    Science.gov (United States)

    Flowe, Heather D; Smith, Harriet M J; Karoğlu, Nilda; Onwuegbusi, Tochukwu O; Rai, Lovedeep

    2016-01-01

    Configural processing supports accurate face recognition, yet it has never been examined within the context of criminal identification lineups. We tested, using the inversion paradigm, the role of configural processing in lineups. Recent research has found that face discrimination accuracy in lineups is better in a simultaneous compared to a sequential lineup procedure. Therefore, we compared configural processing in simultaneous and sequential lineups to examine whether there are differences. We had participants view a crime video, and then they attempted to identify the perpetrator from a simultaneous or sequential lineup. The test faces were presented either upright or inverted, as previous research has shown that inverting test faces disrupts configural processing. The size of the inversion effect for faces was the same across lineup procedures, indicating that configural processing underlies face recognition in both procedures. Discrimination accuracy was comparable across lineup procedures in both the upright and inversion condition. Theoretical implications of the results are discussed.

  14. Representative process sampling - in practice

    DEFF Research Database (Denmark)

    Esbensen, Kim; Friis-Pedersen, Hans Henrik; Julius, Lars Petersen

    2007-01-01

    Didactic data sets representing a range of real-world processes are used to illustrate "how to do" representative process sampling and process characterisation. The selected process data lead to diverse variogram expressions with different systematics (no range vs. important ranges; trends and....../or periodicity; different nugget effects and process variations ranging from less than one lag to full variogram lag). Variogram data analysis leads to a fundamental decomposition into 0-D sampling vs. 1-D process variances, based on the three principal variogram parameters: range, sill and nugget effect...

  15. Operability test procedure for PFP wastewater sampling facility

    International Nuclear Information System (INIS)

    Hirzel, D.R.

    1995-01-01

    Document provides instructions for performing the Operability Test of the 225-WC Wastewater Sampling Station which monitors the discharge to the Treated Effluent Disposal Facility from the Plutonium Finishing Plant. This Operability Test Procedure (OTP) has been prepared to verify correct configuration and performance of the PFP Wastewater sampling system installed in Building 225-WC located outside the perimeter fence southeast of the Plutonium Finishing Plant (PFP). The objective of this test is to ensure the equipment in the sampling facility operates in a safe and reliable manner. The sampler consists of two Manning Model S-5000 units which are rate controlled by the Milltronics Ultrasonic flowmeter at manhole No.C4 and from a pH measuring system with the sensor in the stream adjacent to the sample point. The intent of the dual sampling system is to utilize one unit to sample continuously at a rate proportional to the wastewater flow rate so that the aggregate tests are related to the overall flow and thereby eliminate isolated analyses. The second unit will only operate during a high or low pH excursion of the stream (hence the need for a pH control). The major items in this OTP include testing of the Manning Sampler System and associated equipment including the pH measuring and control system, the conductivity monitor, and the flow meter

  16. Generalized procedures for determining inspection sample sizes (related to quantitative measurements). Vol. 1: Detailed explanations

    International Nuclear Information System (INIS)

    Jaech, J.L.; Lemaire, R.J.

    1986-11-01

    Generalized procedures have been developed to determine sample sizes in connection with the planning of inspection activities. These procedures are based on different measurement methods. They are applied mainly to Bulk Handling Facilities and Physical Inventory Verifications. The present report attempts (i) to assign to appropriate statistical testers (viz. testers for gross, partial and small defects) the measurement methods to be used, and (ii) to associate the measurement uncertainties with the sample sizes required for verification. Working papers are also provided to assist in the application of the procedures. This volume contains the detailed explanations concerning the above mentioned procedures

  17. Theoretical concepts "land management process", "land management procedure" and their relationships

    Directory of Open Access Journals (Sweden)

    Tretiak A.M.

    2017-08-01

    Full Text Available The state significance of land management activities is manifested in those legal consequences that arise after the issuance of land management documentation and are conditioned by the need to secure unsupported land rights and the use and protection of land in a state-guaranteed manner. The procedural activity of land surveyors and other persons authorized by the state to commit land management operations must be carried out in a certain order established by the state and obey the rights and obligations of the persons specified by the legislation at each stage of the development of such relations.The main goal of applying to land management organizations and land surveyors is landuse documentation, which is made in accordance with the requirements of the law and with which the relevant legal properties of the land management procedure are associated. First of all, let's dwell on such basic concepts as "land management process" and "land management procedure". Consideration of the term "land management process" implies a preliminary analysis of the category "process". At the same time, it must be admitted that the development of the procedural form of this category has not been paid attention. Considering the concept of "land management process", its place and role in the system of social relations, emphasis will be placed on the concept of a broad understanding of the legal process, the problem of which exists for decades.Thus, the legal process is a regulated by the procedural rules procedure for the activities of competent state bodies, consisting of the preparation, adoption and documentary consolidation of legal decisions of a general and individual nature. In the land law, the category "process" is specific and serves to designate relationships that provide regulatory and security land-property relationships. Particularly difficult today is the question of the delimitation of the concepts of "process" and "procedure" in general. Regarding

  18. THE SAMPLING PROCESS IN THE FINANCIAL AUDIT .TECHNICAL PRACTICE APPROACH

    Directory of Open Access Journals (Sweden)

    Cardos Vasile-Daniel

    2014-12-01

    “Audit sampling” (sampling assumes appliancing audit procedures for less than 100% of the elements within an account or a trasaction class balance, such that all the samples will be selected. This will allow the auditor to obtain and to evaluate the audit evidence on some features for the selected elements, in purpose to assist or to express a conclusion regardind the population within the sample was extracted. The sampling in audit can use both a statistical or a non-statistical approach. (THE AUDIT INTERNATIONAl STANDARD 530 –THE SAMPLING IN AUDIT AND OTHER SELECTIVE TESTING PROCEDURES

  19. THE SAMPLING PROCESS IN THE FINANCIAL AUDIT .TECHNICAL PRACTICE APPROACH

    Directory of Open Access Journals (Sweden)

    GRIGORE MARIAN

    2014-07-01

    “Audit sampling” (sampling assumes appliancing audit procedures for less than 100% of the elements within an account or a trasaction class balance, such that all the samples will be selected. This will allow the auditor to obtain and to evaluate the audit evidence on some features for the selected elements, in purpose to assist or to express a conclusion regardind the population within the sample was extracted. The sampling in audit can use both a statistical or a non-statistical approach. (THE AUDIT INTERNATIONAl STANDARD 530 –THE SAMPLING IN AUDIT AND OTHER SELECTIVE TESTING PROCEDURES

  20. 32 CFR 1806.3 - Procedures governing acceptance of service of process.

    Science.gov (United States)

    2010-07-01

    ... COUNTERINTELLIGENCE CENTER PROCEDURES GOVERNING ACCEPTANCE OF SERVICE OF PROCESS § 1806.3 Procedures governing acceptance of service of process. (a) Service of Process Upon the NACIC or a NACIC Employee in an Official..., personal service of process may be accepted only by NACIC Counsel, Director, NACIC, or Deputy Director...

  1. Standard operating procedure for combustion of 14C - samples with OX-500 biological material oxidizer

    International Nuclear Information System (INIS)

    Nashriyah Mat.

    1995-01-01

    This procedure is for the purpose of safe operation of OX-500 biological material oxidizer. For ease of operation, the operation flow chart (including testing the system and sample combustion) and end of day maintenance flow chart were simplified. The front view, diagrams and switches are duly copied from operating manual. Steps on sample preparation are also included for biotic and a biotic samples. This operating procedure is subjected to future reviews

  2. Influence of rice sample preparation and milling procedures on milling quality appraisals

    Science.gov (United States)

    The objective of this research was to investigate the effect of sample preparation and milling procedure on milling quality appraisals of rough rice. Samples of freshly harvested medium-grain rice (M202) with different initial moisture contents (MCs) ranging from 20.2% to 25.1% (w.b.) were used for...

  3. Radar Doppler Processing with Nonuniform Sampling.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    Conventional signal processing to estimate radar Doppler frequency often assumes uniform pulse/sample spacing. This is for the convenience of t he processing. More recent performance enhancements in processor capability allow optimally processing nonuniform pulse/sample spacing, thereby overcoming some of the baggage that attends uniform sampling, such as Doppler ambiguity and SNR losses due to sidelobe control measures.

  4. 32 CFR 1904.3 - Procedures governing acceptance of service of process.

    Science.gov (United States)

    2010-07-01

    ... INTELLIGENCE AGENCY PROCEDURES GOVERNING ACCEPTANCE OF SERVICE OF PROCESS § 1904.3 Procedures governing acceptance of service of process. (a) Service of Process Upon the CIA or a CIA Employee in An Official..., personal service of process may be accepted only by attorneys of the Office of General Counsel at CIA...

  5. 32 CFR 1702.3 - Procedures governing acceptance of service of process.

    Science.gov (United States)

    2010-07-01

    ... THE DIRECTOR OF NATIONAL INTELLIGENCE PROCEDURES GOVERNING THE ACCEPTANCE OF SERVICE OF PROCESS § 1702.3 Procedures governing acceptance of service of process. (a) Service of process upon the ODNI or an... authorized by the General Counsel, personal service of process upon the ODNI or an ODNI employee in the...

  6. Influence of Freezing and Storage Procedure on Human Urine Samples in NMR-Based Metabolomics

    Directory of Open Access Journals (Sweden)

    Burkhard Luy

    2013-04-01

    Full Text Available It is consensus in the metabolomics community that standardized protocols should be followed for sample handling, storage and analysis, as it is of utmost importance to maintain constant measurement conditions to identify subtle biological differences. The aim of this work, therefore, was to systematically investigate the influence of freezing procedures and storage temperatures and their effect on NMR spectra as a potentially disturbing aspect for NMR-based metabolomics studies. Urine samples were collected from two healthy volunteers, centrifuged and divided into aliquots. Urine aliquots were frozen either at −20 °C, on dry ice, at −80 °C or in liquid nitrogen and then stored at −20 °C, −80 °C or in liquid nitrogen vapor phase for 1–5 weeks before NMR analysis. Results show spectral changes depending on the freezing procedure, with samples frozen on dry ice showing the largest deviations. The effect was found to be based on pH differences, which were caused by variations in CO2 concentrations introduced by the freezing procedure. Thus, we recommend that urine samples should be frozen at −20 °C and transferred to lower storage temperatures within one week and that freezing procedures should be part of the publication protocol.

  7. Influence of Freezing and Storage Procedure on Human Urine Samples in NMR-Based Metabolomics.

    Science.gov (United States)

    Rist, Manuela J; Muhle-Goll, Claudia; Görling, Benjamin; Bub, Achim; Heissler, Stefan; Watzl, Bernhard; Luy, Burkhard

    2013-04-09

    It is consensus in the metabolomics community that standardized protocols should be followed for sample handling, storage and analysis, as it is of utmost importance to maintain constant measurement conditions to identify subtle biological differences. The aim of this work, therefore, was to systematically investigate the influence of freezing procedures and storage temperatures and their effect on NMR spectra as a potentially disturbing aspect for NMR-based metabolomics studies. Urine samples were collected from two healthy volunteers, centrifuged and divided into aliquots. Urine aliquots were frozen either at -20 °C, on dry ice, at -80 °C or in liquid nitrogen and then stored at -20 °C, -80 °C or in liquid nitrogen vapor phase for 1-5 weeks before NMR analysis. Results show spectral changes depending on the freezing procedure, with samples frozen on dry ice showing the largest deviations. The effect was found to be based on pH differences, which were caused by variations in CO2 concentrations introduced by the freezing procedure. Thus, we recommend that urine samples should be frozen at -20 °C and transferred to lower storage temperatures within one week and that freezing procedures should be part of the publication protocol.

  8. New procedure of selected biogenic amines determination in wine samples by HPLC

    Energy Technology Data Exchange (ETDEWEB)

    Piasta, Anna M.; Jastrzębska, Aneta, E-mail: aj@chem.uni.torun.pl; Krzemiński, Marek P.; Muzioł, Tadeusz M.; Szłyk, Edward

    2014-06-27

    Highlights: • We proposed new procedure for derivatization of biogenic amines. • The NMR and XRD analysis confirmed the purity and uniqueness of derivatives. • Concentration of biogenic amines in wine samples were analyzed by RP-HPLC. • Sample contamination and derivatization reactions interferences were minimized. - Abstract: A new procedure for determination of biogenic amines (BA): histamine, phenethylamine, tyramine and tryptamine, based on the derivatization reaction with 2-chloro-1,3-dinitro-5-(trifluoromethyl)-benzene (CNBF), is proposed. The amines derivatives with CNBF were isolated and characterized by X-ray crystallography and {sup 1}H, {sup 13}C, {sup 19}F NMR spectroscopy in solution. The novelty of the procedure is based on the pure and well-characterized products of the amines derivatization reaction. The method was applied for the simultaneous analysis of the above mentioned biogenic amines in wine samples by the reversed phase-high performance liquid chromatography. The procedure revealed correlation coefficients (R{sup 2}) between 0.9997 and 0.9999, and linear range: 0.10–9.00 mg L{sup −1} (histamine); 0.10–9.36 mg L{sup -1} (tyramine); 0.09–8.64 mg L{sup −1} (tryptamine) and 0.10–8.64 mg L{sup −1} (phenethylamine), whereas accuracy was 97%–102% (recovery test). Detection limit of biogenic amines in wine samples was 0.02–0.03 mg L{sup −1}, whereas quantification limit ranged 0.05–0.10 mg L{sup −1}. The variation coefficients for the analyzed amines ranged between 0.49% and 3.92%. Obtained BA derivatives enhanced separation the analytes on chromatograms due to the inhibition of hydrolysis reaction and the reduction of by-products formation.

  9. Synthetic Multiple-Imputation Procedure for Multistage Complex Samples

    Directory of Open Access Journals (Sweden)

    Zhou Hanzhi

    2016-03-01

    Full Text Available Multiple imputation (MI is commonly used when item-level missing data are present. However, MI requires that survey design information be built into the imputation models. For multistage stratified clustered designs, this requires dummy variables to represent strata as well as primary sampling units (PSUs nested within each stratum in the imputation model. Such a modeling strategy is not only operationally burdensome but also inferentially inefficient when there are many strata in the sample design. Complexity only increases when sampling weights need to be modeled. This article develops a generalpurpose analytic strategy for population inference from complex sample designs with item-level missingness. In a simulation study, the proposed procedures demonstrate efficient estimation and good coverage properties. We also consider an application to accommodate missing body mass index (BMI data in the analysis of BMI percentiles using National Health and Nutrition Examination Survey (NHANES III data. We argue that the proposed methods offer an easy-to-implement solution to problems that are not well-handled by current MI techniques. Note that, while the proposed method borrows from the MI framework to develop its inferential methods, it is not designed as an alternative strategy to release multiply imputed datasets for complex sample design data, but rather as an analytic strategy in and of itself.

  10. Ergonomic analysis of radiopharmaceuticals samples preparation process

    International Nuclear Information System (INIS)

    Gomes, Luciene Betzler C.; Santos, Isaac Luquetti dos; Fonseca, Antonio Carlos C. da; Pellini, Marcos Pinto; Rebelo, Ana Maria

    2005-01-01

    The doses of radioisotopes to be administrated in patients for diagnostic effect or therapy are prepared in the radiopharmacological sector. The preparation process adopts techniques that are aimed to reduce the exposition time of the professionals and the absorption of excessive doses for patients. The ergonomic analysis of this process contributes in the prevention of occupational illnesses and to prevent risks of accidents during the routines, providing welfare and security to the involved users and conferring to the process an adequate working standard. In this context it is perceived relevance of studies that deal with the analysis of factors that point with respect to the solution of problems and for establishing proposals that minimize risks in the exercise of the activities. Through a methodology that considers the application of the concepts of Ergonomics, it is searched the improvement of the effectiveness or the quality and reduction of the difficulties lived for the workers. The work prescribed, established through norms and procedures codified will be faced with the work effectively carried through, the real work, shaped to break the correct appreciation, with focus in the activities. This work has as objective to argue an ergonomic analysis of samples preparation process of radioisotopes in the Setor de Radiofarmacia do Hospital Universitario Clementino Fraga Filho da Universidade Federal do Rio de Janeiro (UFRJ). (author)

  11. Critical evaluation of distillation procedure for the determination of methylmercury in soil samples.

    Science.gov (United States)

    Perez, Pablo A; Hintelman, Holger; Quiroz, Waldo; Bravo, Manuel A

    2017-11-01

    In the present work, the efficiency of distillation process for extracting monomethylmercury (MMHg) from soil samples was studied and optimized using an experimental design methodology. The influence of soil composition on MMHg extraction was evaluated by testing of four soil samples with different geochemical characteristics. Optimization suggested that the acid concentration and the duration of the distillation process were most significant and the most favorable conditions, established as a compromise for the studied soils, were determined to be a 70 min distillation using an 0.2 M acid. Corresponding limits of detection (LOD) and quantification (LOQ) were 0.21 and 0.7 pg absolute, respectively. The optimized methodology was applied with satisfactory results to soil samples and was compared to a reference methodology based on isotopic dilution analysis followed by gas chromatography-inductively coupled plasma mass spectrometry (IDA-GC-ICP-MS). Using the optimized conditions, recoveries ranged from 82 to 98%, which is an increase of 9-34% relative to the previously used standard operating procedure. Finally, the validated methodology was applied to quantify MMHg in soils collected from different sites impacted by coal fired power plants in the north-central zone of Chile, measuring MMHg concentrations ranging from 0.091 to 2.8 ng g -1 . These data are to the best of our knowledge the first MMHg measurements reported for Chile. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Procedural Due Process and Fairness in Student Discipline. A Legal Memorandum.

    Science.gov (United States)

    Johnson, T. Page

    When the Supreme Court decided that the Constitution requires public school principals to follow procedural due process in suspension and expulsion cases, the Justices recognized a link between procedural due process and the fairness of effective discipline. This report reviews the constitutional due process required when public school officials…

  13. Pretreatment procedures applied to samples to be analysed by neutron activation analysis at CDTN/CNEN

    International Nuclear Information System (INIS)

    Francisco, Dovenir; Menezes, Maria Angela de Barros Correia

    2009-01-01

    The neutron activation technique - using several methods - has been applied in 80% of the analytical demand of Division for Reactor and Analytical Techniques at CDTN/CNEN, Belo Horizonte, Minas Gerais. This scenario emphasizes the responsibility of the Laboratory to provide and assure the quality of the measurements. The first step to assure the results quality is the preparation of the samples. Therefore, this paper describes the experimental procedures adopted at CDTN/CNEN in order to uniform conditions of analysis and to avoid contaminations by elements present everywhere. Some of the procedures are based on methods described in the literature; others are based on many years of experience preparing samples from many kinds of matrices. The procedures described are related to geological material - soil, sediment, rock, gems, clay, archaeological ceramics and ore - biological materials - hair, fish, plants, food - water, etc. Analytical results in sediment samples are shown as n example pointing out the efficiency of the experimental procedure. (author)

  14. Sample preparation procedure for PIXE elemental analysis on soft tissues

    International Nuclear Information System (INIS)

    Kubica, B.; Kwiatek, W.M.; Dutkiewicz, E.M.; Lekka, M.

    1997-01-01

    Trace element analysis is one of the most important field in analytical chemistry. There are several instrumental techniques which are applied for determinations of microscopic elemental content. The PIXE (Proton Induced X-ray Emission) technique is one of the nuclear techniques that is commonly applied for such purpose due to its multielemental analysis possibilities. The aim of this study was to establish the optimal conditions for target preparation procedure. In this paper two different approaches to the topic are presented and widely discussed. The first approach was the traditional pellet technique and the second one was mineralization procedure. For the analysis soft tissue such as liver was used. Some results are also presented on water samples. (author)

  15. A Procedure for Splitting Processes and its Application to Coordination (Technical Report)

    NARCIS (Netherlands)

    S.-S.T.Q. Jongmans (Sung-Shik); D.G. Clarke (David); J.M.P. Proença (Jose)

    2012-01-01

    textabstractWe present a procedure for splitting processes in a process algebra with multi-actions (a subset of the specification language mCRL2). This splitting procedure cuts a process into two processes along a set of actions A: roughly, one of these processes contains no actions from A, while

  16. Procedures for central auditory processing screening in schoolchildren.

    Science.gov (United States)

    Carvalho, Nádia Giulian de; Ubiali, Thalita; Amaral, Maria Isabel Ramos do; Santos, Maria Francisca Colella

    2018-03-22

    Central auditory processing screening in schoolchildren has led to debates in literature, both regarding the protocol to be used and the importance of actions aimed at prevention and promotion of auditory health. Defining effective screening procedures for central auditory processing is a challenge in Audiology. This study aimed to analyze the scientific research on central auditory processing screening and discuss the effectiveness of the procedures utilized. A search was performed in the SciELO and PUBMed databases by two researchers. The descriptors used in Portuguese and English were: auditory processing, screening, hearing, auditory perception, children, auditory tests and their respective terms in Portuguese. original articles involving schoolchildren, auditory screening of central auditory skills and articles in Portuguese or English. studies with adult and/or neonatal populations, peripheral auditory screening only, and duplicate articles. After applying the described criteria, 11 articles were included. At the international level, central auditory processing screening methods used were: screening test for auditory processing disorder and its revised version, screening test for auditory processing, scale of auditory behaviors, children's auditory performance scale and Feather Squadron. In the Brazilian scenario, the procedures used were the simplified auditory processing assessment and Zaidan's battery of tests. At the international level, the screening test for auditory processing and Feather Squadron batteries stand out as the most comprehensive evaluation of hearing skills. At the national level, there is a paucity of studies that use methods evaluating more than four skills, and are normalized by age group. The use of simplified auditory processing assessment and questionnaires can be complementary in the search for an easy access and low-cost alternative in the auditory screening of Brazilian schoolchildren. Interactive tools should be proposed, that

  17. Selective extraction of chromium(VI) using a leaching procedure with sodium carbonate from some plant leaves, soil and sediment samples

    Energy Technology Data Exchange (ETDEWEB)

    Elci, Latif, E-mail: elci@pamukkale.edu.tr [Department of Chemistry, Pamukkale University, 20017 Denizli (Turkey); Divrikli, Umit; Akdogan, Abdullah; Hol, Aysen; Cetin, Ayse [Department of Chemistry, Pamukkale University, 20017 Denizli (Turkey); Soylak, Mustafa [Department of Chemistry, Erciyes University, 38039 Kayseri (Turkey)

    2010-01-15

    Speciation of chromium in some plant leaves, soil and sediment samples was carried out by selective leaching of Cr(VI) using a sodium carbonate leaching procedure. Total chromium from the samples was extracted using aqua regia and oxidative acid digestion, respectively. The concentrations of chromium species in the extracts were determined using by graphite furnace atomic absorption spectrometry (GFAAS). Uncoated graphite furnace tubes were used as an atomizer. Due to the presence of relatively high amounts of Na{sub 2}CO{sub 3} in the resulting samples, the possible influences of Na{sub 2}CO{sub 3} on the absorbance signals were checked. There is no interference of Na{sub 2}CO{sub 3} on the chromium absorbance up to 0.1 mol L{sup -1} Na{sub 2}CO{sub 3}. A limit of detection (LOD) for determination of Cr(VI) in 0.1 Na{sub 2}CO{sub 3} solution by GFAAS was found to be 0.93 {mu}g L{sup -1}. The procedure was applied to environmental samples. The relative standard deviation, R.S.D. as precision for 10 replicate measurements of 20 {mu} L{sup -1} Cr in processed soil sample was 4.2%.

  18. Selective extraction of chromium(VI) using a leaching procedure with sodium carbonate from some plant leaves, soil and sediment samples.

    Science.gov (United States)

    Elci, Latif; Divrikli, Umit; Akdogan, Abdullah; Hol, Aysen; Cetin, Ayse; Soylak, Mustafa

    2010-01-15

    Speciation of chromium in some plant leaves, soil and sediment samples was carried out by selective leaching of Cr(VI) using a sodium carbonate leaching procedure. Total chromium from the samples was extracted using aqua regia and oxidative acid digestion, respectively. The concentrations of chromium species in the extracts were determined using by graphite furnace atomic absorption spectrometry (GFAAS). Uncoated graphite furnace tubes were used as an atomizer. Due to the presence of relatively high amounts of Na(2)CO(3) in the resulting samples, the possible influences of Na(2)CO(3) on the absorbance signals were checked. There is no interference of Na(2)CO(3) on the chromium absorbance up to 0.1 mol L(-1) Na(2)CO(3). A limit of detection (LOD) for determination of Cr(VI) in 0.1 Na(2)CO(3) solution by GFAAS was found to be 0.93 microg L(-1). The procedure was applied to environmental samples. The relative standard deviation, R.S.D. as precision for 10 replicate measurements of 20 microL(-1) Cr in processed soil sample was 4.2%.

  19. Procedures for the collection and preservation of groundwater and surface water samples and for the installation of monitoring wells

    International Nuclear Information System (INIS)

    Korte, N.; Kearl, P.

    1984-01-01

    Proper sampling procedures are essential for a successful water-quality monitoring program. It must be emphasized, however, that it is impossible to maintain absolutely in-situ conditions when collecting and preserving a water sample, whether from a flowing stream or an aquifer. Consequently, the most that can reasonably be expected is to collect a best possible sample with minimal disturbance. This document describes procedures for installing monitoring wells and for collecting samples of surface water and groundwater. The discussion of monitoring wells includes mention of multilevel sampling and a general overview of vadose-zone monitoring. Guidelines for well installation are presented in detail. The discussion of water-sample collection contains evaluations of sampling pumps, filtration equipment, and sample containers. Sample-preservation techniques, as published by several government and private sources, are reviewed. Finally, step-by-step procedures for collection of water samples are provided; these procedures address such considerations as necessary equipment, field operations, and written documentation. Separate procedures are also included for the collection of samples for determination of sulfide and for reactive aluminum. The report concludes with a brief discussion of adverse sampling, conditions that may significantly affect the quality of the data. Appendix A presents a rationale for the development and use of statistical considerations in water sampling to ensure a more complete water quality monitoring program. 51 references, 9 figures, 4 tables

  20. A recommended procedure for establishing the source level relationships between heroin case samples of unknown origins

    Directory of Open Access Journals (Sweden)

    Kar-Weng Chan

    2014-06-01

    Full Text Available A recent concern of how to reliably establish the source level relationships of heroin case samples is addressed in this paper. Twenty-two trafficking heroin case samples of unknown origins seized from two major regions (Kuala Lumpur and Penang in Malaysia were studied. A procedure containing six major steps was followed to analyze and classify these samples. Subsequently, with the aid of statistical control samples, reliability of the clustering result was assessed. The final outcome reveals that the samples seized from the two regions in 2013 had highly likely originated from two different sources. Hence, the six-step procedure is sufficient for any chemist who attempts to assess the relative source level relationships of heroin samples.

  1. Sample registration software for process automation in the Neutron Activation Analysis (NAA) Facility in Malaysia nuclear agency

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, Nur Aira Abd, E-mail: nur-aira@nuclearmalaysia.gov.my; Yussup, Nolida; Ibrahim, Maslina Bt. Mohd; Mokhtar, Mukhlis B.; Soh Shaari, Syirrazie Bin Che; Azman, Azraf B. [Technical Support Division, Malaysian Nuclear Agency, 43000, Kajang, Selangor (Malaysia); Salim, Nazaratul Ashifa Bt. Abdullah [Division of Waste and Environmental Technology, Malaysian Nuclear Agency, 43000, Kajang, Selangor (Malaysia); Ismail, Nadiah Binti [Fakulti Kejuruteraan Elektrik, UiTM Pulau Pinang, 13500 Permatang Pauh, Pulau Pinang (Malaysia)

    2015-04-29

    Neutron Activation Analysis (NAA) had been established in Nuclear Malaysia since 1980s. Most of the procedures established were done manually including sample registration. The samples were recorded manually in a logbook and given ID number. Then all samples, standards, SRM and blank were recorded on the irradiation vial and several forms prior to irradiation. These manual procedures carried out by the NAA laboratory personnel were time consuming and not efficient. Sample registration software is developed as part of IAEA/CRP project on ‘Development of Process Automation in the Neutron Activation Analysis (NAA) Facility in Malaysia Nuclear Agency (RC17399)’. The objective of the project is to create a pc-based data entry software during sample preparation stage. This is an effective method to replace redundant manual data entries that needs to be completed by laboratory personnel. The software developed will automatically generate sample code for each sample in one batch, create printable registration forms for administration purpose, and store selected parameters that will be passed to sample analysis program. The software is developed by using National Instruments Labview 8.6.

  2. Sample registration software for process automation in the Neutron Activation Analysis (NAA) Facility in Malaysia nuclear agency

    Science.gov (United States)

    Rahman, Nur Aira Abd; Yussup, Nolida; Salim, Nazaratul Ashifa Bt. Abdullah; Ibrahim, Maslina Bt. Mohd; Mokhtar, Mukhlis B.; Soh@Shaari, Syirrazie Bin Che; Azman, Azraf B.; Ismail, Nadiah Binti

    2015-04-01

    Neutron Activation Analysis (NAA) had been established in Nuclear Malaysia since 1980s. Most of the procedures established were done manually including sample registration. The samples were recorded manually in a logbook and given ID number. Then all samples, standards, SRM and blank were recorded on the irradiation vial and several forms prior to irradiation. These manual procedures carried out by the NAA laboratory personnel were time consuming and not efficient. Sample registration software is developed as part of IAEA/CRP project on `Development of Process Automation in the Neutron Activation Analysis (NAA) Facility in Malaysia Nuclear Agency (RC17399)'. The objective of the project is to create a pc-based data entry software during sample preparation stage. This is an effective method to replace redundant manual data entries that needs to be completed by laboratory personnel. The software developed will automatically generate sample code for each sample in one batch, create printable registration forms for administration purpose, and store selected parameters that will be passed to sample analysis program. The software is developed by using National Instruments Labview 8.6.

  3. A radiochemical procedure for the determination of Po-210 in environmental samples

    International Nuclear Information System (INIS)

    Godoy, J.M.; Schuettelkopf, H.

    1980-07-01

    A radiochemical procedure for the determination of Po-210 in environmental samples was developed. Soil, sediments, filter materials, plants, water and food samples can be analyzed for Po-210. Wet ashing is achieved with HNO 3 + H 2 O 2 or HCl + HNO 3 . To separate disturbing substances, a coprecipitation with Te is used for sample materials containing silica. Po-210 deposition from HCl solution on Ag platelets with other sample materials is possible directly. Deposited Po-210 is counted by α-spectrometry. For chemical yield determination Po-208 is added, yields range between 60% and 100%. A lower detection limit of about 0,002 pCi Po-210/sample is achievable. (orig./HP) [de

  4. Coracoid process x-ray investigation before Latarjet procedure: a radioanatomic study.

    Science.gov (United States)

    Bachy, Manon; Lapner, Peter L C; Goutallier, Daniel; Allain, Jérôme; Hernigou, Phillipe; Bénichou, Jacques; Zilber, Sébastien

    2013-12-01

    The purpose of this study was to determine whether a preoperative radiologic assessment of the coracoid process is predictive of the amount of bone available for coracoid transfer by the Latarjet procedure. Thirty-five patients with anterior instability undergoing a Latarjet procedure were included. A preoperative radiologic assessment was performed with the Bernageau and true anteroposterior (true AP) views. The length of the coracoid process was measured on both radiographic views and the values were compared with the length of the bone block during surgery. Statistical analysis was carried out by ANOVA and Wilcoxon tests (P process length was 29 ± 4 and 33 ± 4 mm on the Bernageau and true AP views, respectively. The mean bone block length during surgery was 21.6 ± 2.7 mm. A significant correlation was found (P = .032) between the coracoid process length on the true AP view and the intraoperative bone block length. Preoperative planning for the Latarjet procedure, including graft orientation and screw placement, requires knowledge of the length of coracoid bone available for transfer. This can be facilitated with the use of preoperative standard radiographs, thus avoiding computed tomography. This planning allows the detection of coracoid process anatomic variations or the analysis of the remaining part of the coracoid process after failure of a first Latarjet procedure to avoid an iliac bone graft. Radiologic preoperative coracoid process measurement is an easy, reliable method to aid preoperative planning of the Latarjet procedure in primary surgery and reoperations. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.

  5. Wavelet data processing of micro-Raman spectra of biological samples

    Science.gov (United States)

    Camerlingo, C.; Zenone, F.; Gaeta, G. M.; Riccio, R.; Lepore, M.

    2006-02-01

    A wavelet multi-component decomposition algorithm is proposed for processing data from micro-Raman spectroscopy (μ-RS) of biological tissue. The μ-RS has been recently recognized as a promising tool for the biopsy test and in vivo diagnosis of degenerative human tissue pathologies, due to the high chemical and structural information contents of this spectroscopic technique. However, measurements of biological tissues are usually hampered by typically low-level signals and by the presence of noise and background components caused by light diffusion or fluorescence processes. In order to overcome these problems, a numerical method based on discrete wavelet transform is used for the analysis of data from μ-RS measurements performed in vitro on animal (pig and chicken) tissue samples and, in a preliminary form, on human skin and oral tissue biopsy from normal subjects. Visible light μ-RS was performed using a He-Ne laser and a monochromator with a liquid nitrogen cooled charge coupled device equipped with a grating of 1800 grooves mm-1. The validity of the proposed data procedure has been tested on the well-characterized Raman spectra of reference acetylsalicylic acid samples.

  6. Sampling procedures and tables

    International Nuclear Information System (INIS)

    Franzkowski, R.

    1980-01-01

    Characteristics, defects, defectives - Sampling by attributes and by variables - Sample versus population - Frequency distributions for the number of defectives or the number of defects in the sample - Operating characteristic curve, producer's risk, consumer's risk - Acceptable quality level AQL - Average outgoing quality AOQ - Standard ISQ 2859 - Fundamentals of sampling by variables for fraction defective. (RW)

  7. A procedure for the determination of Po-210 in water samples by alpha spectrometry

    International Nuclear Information System (INIS)

    2009-01-01

    Reliable, comparable and 'fit for purpose' results are an essential requirement for any decision based on analytical measurements. For the analyst, the availability of tested and validated analytical procedures is a extremely important tool for production of such analytical measurements. For maximum utility, such procedures should be comprehensive, clearly formulated, and readily available to both the analyst and the customer for reference. Since 2004 the Environment programme of the IAEA has included activities aimed at the development of a set of procedures for the determination of radionuclides in terrestrial environmental samples. In the case of 210 Po, this started with the collection and review of about 130 papers from the scientific literature. Based on this review, two candidate methods for the chemical separation of 210 Po from water samples were selected for testing, refinement and validation in accordance with ISO guidelines. A comprehensive methodology for calculation of results including quantification of measurement uncertainty was also developed. This report presents the final procedure which was developed based on that work

  8. Sampling procedure for lake or stream surface water chemistry

    Science.gov (United States)

    Robert Musselman

    2012-01-01

    Surface waters collected in the field for chemical analyses are easily contaminated. This research note presents a step-by-step detailed description of how to avoid sample contamination when field collecting, processing, and transporting surface water samples for laboratory analysis.

  9. Two-step estimation procedures for inhomogeneous shot-noise Cox processes

    DEFF Research Database (Denmark)

    Prokesová, Michaela; Dvorák, Jirí; Jensen, Eva B. Vedel

    In the present paper we develop several two-step estimation procedures for inhomogeneous shot-noise Cox processes. The intensity function is parametrized by the inhomogeneity parameters while the pair-correlation function is parametrized by the interaction parameters. The suggested procedures...

  10. Dimethyl adipimidate/Thin film Sample processing (DTS); A simple, low-cost, and versatile nucleic acid extraction assay for downstream analysis.

    Science.gov (United States)

    Shin, Yong; Lim, Swee Yin; Lee, Tae Yoon; Park, Mi Kyoung

    2015-09-15

    Sample processing, especially that involving nucleic acid extraction, is a prerequisite step for the isolation of high quantities of relatively pure DNA for downstream analyses in many life science and biomedical engineering studies. However, existing methods still have major problems, including labor-intensive time-consuming methods and high costs, as well as requirements for a centrifuge and the complex fabrication of filters and membranes. Here, we first report a versatile Dimethyl adipimidate/Thin film based Sample processing (DTS) procedure without the limitations of existing methods. This procedure is useful for the extraction of DNA from a variety of sources, including 6 eukaryotic cells, 6 bacteria cells, and 2 body fluids in a single step. Specifically, the DTS procedure does not require a centrifuge and has improved time efficiency (30 min), affordability, and sensitivity in downstream analysis. We validated the DTS procedure for the extraction of DNA from human body fluids, as well as confirmed that the quality and quantity of the extracted DNA were sufficient to allow robust detection of genetic and epigenetic biomarkers in downstream analysis.

  11. Modified FlowCAM procedure for quantifying size distribution of zooplankton with sample recycling capacity.

    Directory of Open Access Journals (Sweden)

    Esther Wong

    Full Text Available We have developed a modified FlowCAM procedure for efficiently quantifying the size distribution of zooplankton. The modified method offers the following new features: 1 prevents animals from settling and clogging with constant bubbling in the sample container; 2 prevents damage to sample animals and facilitates recycling by replacing the built-in peristaltic pump with an external syringe pump, in order to generate negative pressure, creates a steady flow by drawing air from the receiving conical flask (i.e. vacuum pump, and transfers plankton from the sample container toward the main flowcell of the imaging system and finally into the receiving flask; 3 aligns samples in advance of imaging and prevents clogging with an additional flowcell placed ahead of the main flowcell. These modifications were designed to overcome the difficulties applying the standard FlowCAM procedure to studies where the number of individuals per sample is small, and since the FlowCAM can only image a subset of a sample. Our effective recycling procedure allows users to pass the same sample through the FlowCAM many times (i.e. bootstrapping the sample in order to generate a good size distribution. Although more advanced FlowCAM models are equipped with syringe pump and Field of View (FOV flowcells which can image all particles passing through the flow field; we note that these advanced setups are very expensive, offer limited syringe and flowcell sizes, and do not guarantee recycling. In contrast, our modifications are inexpensive and flexible. Finally, we compared the biovolumes estimated by automated FlowCAM image analysis versus conventional manual measurements, and found that the size of an individual zooplankter can be estimated by the FlowCAM image system after ground truthing.

  12. Systematic sampling with errors in sample locations

    DEFF Research Database (Denmark)

    Ziegel, Johanna; Baddeley, Adrian; Dorph-Petersen, Karl-Anton

    2010-01-01

    analysis using point process methods. We then analyze three different models for the error process, calculate exact expressions for the variances, and derive asymptotic variances. Errors in the placement of sample points can lead to substantial inflation of the variance, dampening of zitterbewegung......Systematic sampling of points in continuous space is widely used in microscopy and spatial surveys. Classical theory provides asymptotic expressions for the variance of estimators based on systematic sampling as the grid spacing decreases. However, the classical theory assumes that the sample grid...... is exactly periodic; real physical sampling procedures may introduce errors in the placement of the sample points. This paper studies the effect of errors in sample positioning on the variance of estimators in the case of one-dimensional systematic sampling. First we sketch a general approach to variance...

  13. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples

    DEFF Research Database (Denmark)

    Skogstrand, K.; Thorsen, P.; Vogel, I.

    2008-01-01

    of whole blood samples at low temperatures and rapid isolation of plasma and serum. Effects of different handling procedures for all markers studied are given. DBSS proved to be a robust and convenient way to handle samples for immunoassay analysis of inflammatory markers in whole blood Udgivelsesdato......The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected...... and stored for other purposes, justifies the study hereof. Blood samples were stored for 0, 4, 24, and 48 h at 4 degrees C, room temperature (RT), and at 35 degrees C, respectively, before they were separated into serum or plasma and frozen. Dried blood spot samples (DBSS) were stored for 0, 1, 2, 3, 7...

  14. Sampling procedure in a willow plantation for estimation of moisture content

    DEFF Research Database (Denmark)

    Nielsen, Henrik Kofoed; Lærke, Poul Erik; Liu, Na

    2015-01-01

    Heating value and fuel quality of wood is closely connected to moisture content. In this work the variation of moisture content (MC) of short rotation coppice (SRC) willow shoots is described for five clones during one harvesting season. Subsequently an appropriate sampling procedure minimising...... labour costs and sampling uncertainty is proposed, where the MC of a single stem section with the length of 10–50 cm corresponds to the mean shoot moisture content (MSMC) with a bias of maximum 11 g kg−1. This bias can be reduced by selecting the stem section according to the particular clone...

  15. Experimental procedure for the determination of counting efficiency and sampling flow rate of a grab-sampling working level meter

    International Nuclear Information System (INIS)

    Grenier, M.; Bigu, J.

    1982-07-01

    The calibration procedures used for a working level meter (WLM) of the grab-sampling type are presented in detail. The WLM tested is a Pylon WL-1000C working level meter and it was calibrated for radon/thoron daughter counting efficiency (E), for sampling pump flow rate (Q) and other variables of interest. For the instrument calibrated at the Elliot Lake Laboratory, E was 0.22 +- 0.01 while Q was 4.50 +- 0.01 L/min

  16. Rapid Microwave Digestion Procedures for the Elemental Analysis of Alloy and Slag Samples of Smelted Ocean Bed Polymetallic Nodules

    Directory of Open Access Journals (Sweden)

    Kumari Smita

    2013-01-01

    Full Text Available The use of microwave digester for digestion of alloy and slag samples of smelted ocean bed polymetallic nodules has permitted the complete digestion of samples, thereby replacing the tedious classical methods of digestion of samples. The digestion procedure includes two acid-closed digestions of samples in a microwave oven. Owing to the hazardous nature of perchloric acid, it was not used in developed digestion procedure. Digested sample solutions were analyzed for concentrations of various radicals and the effectiveness of the developed digestion methodology was tested using certified reference materials. It was found that the developed method is giving results comparable with that obtained from conventionally digested samples. In this digestion procedure, time required for digestion of samples was reduced to about 1 hour only from 8-9 hours of conventional digestion.

  17. Procedural justice and quality of life in compensation processes.

    Science.gov (United States)

    Elbers, Nieke A; Akkermans, Arno J; Cuijpers, Pim; Bruinvels, David J

    2013-11-01

    There is considerable evidence that being involved in compensation processes has a negative impact on claimants' health. Previous studies suggested that this negative effect is caused by a stressful compensation process: claimants suffered from a lack of communication, a lack of information, and feelings of distrust. However, these rather qualitative findings have not been quantitatively investigated yet. This observational study aimed to fill this gap of knowledge, investigating the claimants' perceived fairness of the compensation process, the provided information, and the interaction with lawyers and insurance companies, in relation to the claimants' quality of life. Participants were individuals injured in traffic accidents, older than 18 years, who were involved in a compensation process in the Netherlands. They were recruited by three claims settlement offices. Outcome measures were procedural, interactional, and informational justice, and quality of life. Participants (n=176) perceived the interaction with lawyers to be fairer than the interaction with insurance companies (pquality of life (rs=.22, p=.004). The finding that the interaction with insurance companies was considered less fair than the interaction with lawyers may imply that insurers could improve their interaction with claimants, e.g. by communicating more directly. The result that claimants with mild injuries and with trunk/back injuries considered the compensation process to be less fair than those with respectively severe injuries and injuries to other body parts suggests that especially the former two require an attentive treatment. Finally, the fact that procedural justice was positively correlated with quality of life could implicate that it is possible to improve claimants' health in compensation processes by enhancing procedural justice, e.g. by increasing the ability for claimants to express their views and feelings and by involving claimants in the decision-making process. Copyright

  18. Direct methylation procedure for converting fatty amides to fatty acid methyl esters in feed and digesta samples.

    Science.gov (United States)

    Jenkins, T C; Thies, E J; Mosley, E E

    2001-05-01

    Two direct methylation procedures often used for the analysis of total fatty acids in biological samples were evaluated for their application to samples containing fatty amides. Methylation of 5 mg of oleamide (cis-9-octadecenamide) in a one-step (methanolic HCl for 2 h at 70 degrees C) or a two-step (sodium methoxide for 10 min at 50 degrees C followed by methanolic HCl for 10 min at 80 degrees C) procedure gave 59 and 16% conversions of oleamide to oleic acid, respectively. Oleic acid recovery from oleamide was increased to 100% when the incubation in methanolic HCl was lengthened to 16 h and increased to 103% when the incubation in methoxide was modified to 24 h at 100 degrees C. However, conversion of oleamide to oleic acid in an animal feed sample was incomplete for the modified (24 h) two-step procedure but complete for the modified (16 h) one-step procedure. Unsaturated fatty amides in feed and digesta samples can be converted to fatty acid methyl esters by incubation in methanolic HCl if the time of exposure to the acid catalyst is extended from 2 to 16 h.

  19. Sample processing device and method

    DEFF Research Database (Denmark)

    2011-01-01

    A sample processing device is disclosed, which sample processing device comprises a first substrate and a second substrate, where the first substrate has a first surface comprising two area types, a first area type with a first contact angle with water and a second area type with a second contact...... angle with water, the first contact angle being smaller than the second contact angle. The first substrate defines an inlet system and a preparation system in areas of the first type which two areas are separated by a barrier system in an area of the second type. The inlet system is adapted to receive...

  20. 10 CFR 451.9 - Procedures for processing applications.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Procedures for processing applications. 451.9 Section 451.9 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION RENEWABLE ENERGY PRODUCTION INCENTIVES § 451.9... or operators of qualified renewable energy facilities using solar, wind, ocean, geothermal, and...

  1. Analysis of plant gums and saccharide materials in paint samples: comparison of GC-MS analytical procedures and databases.

    Science.gov (United States)

    Lluveras-Tenorio, Anna; Mazurek, Joy; Restivo, Annalaura; Colombini, Maria Perla; Bonaduce, Ilaria

    2012-10-10

    Saccharide materials have been used for centuries as binding media, to paint, write and illuminate manuscripts and to apply metallic leaf decorations. Although the technical literature often reports on the use of plant gums as binders, actually several other saccharide materials can be encountered in paint samples, not only as major binders, but also as additives. In the literature, there are a variety of analytical procedures that utilize GC-MS to characterize saccharide materials in paint samples, however the chromatographic profiles are often extremely different and it is impossible to compare them and reliably identify the paint binder. This paper presents a comparison between two different analytical procedures based on GC-MS for the analysis of saccharide materials in works-of-art. The research presented here evaluates the influence of the analytical procedure used, and how it impacts the sugar profiles obtained from the analysis of paint samples that contain saccharide materials. The procedures have been developed, optimised and systematically used to characterise plant gums at the Getty Conservation Institute in Los Angeles, USA (GCI) and the Department of Chemistry and Industrial Chemistry of the University of Pisa, Italy (DCCI). The main steps of the analytical procedures and their optimisation are discussed. The results presented highlight that the two methods give comparable sugar profiles, whether the samples analysed are simple raw materials, pigmented and unpigmented paint replicas, or paint samples collected from hundreds of centuries old polychrome art objects. A common database of sugar profiles of reference materials commonly found in paint samples was thus compiled. The database presents data also from those materials that only contain a minor saccharide fraction. This database highlights how many sources of saccharides can be found in a paint sample, representing an important step forward in the problem of identifying polysaccharide binders in

  2. Robotic system for process sampling

    International Nuclear Information System (INIS)

    Dyches, G.M.

    1985-01-01

    A three-axis cartesian geometry robot for process sampling was developed at the Savannah River Laboratory (SRL) and implemented in one of the site radioisotope separations facilities. Use of the robot reduces personnel radiation exposure and contamination potential by routinely handling sample containers under operator control in a low-level radiation area. This robot represents the initial phase of a longer term development program to use robotics for further sample automation. Preliminary design of a second generation robot with additional capabilities is also described. 8 figs

  3. The Influence of Sample Drying Procedures on Mercury Concentrations Analyzed in Soils

    Czech Academy of Sciences Publication Activity Database

    Hojdová, Maria; Rohovec, Jan; Chrastný, V.; Penížek, V.; Navrátil, Tomáš

    2015-01-01

    Roč. 94, č. 5 (2015), s. 570-576 ISSN 0007-4861 R&D Projects: GA ČR GP526/09/P404; GA ČR(CZ) GAP210/11/1369 Institutional support: RVO:67985831 Keywords : sample preparation * drying procedures * microbial activity * freeze-drying * contamination Subject RIV: DD - Geochemistry Impact factor: 1.191, year: 2015

  4. Measuring automatic retrieval: a comparison of implicit memory, process dissociation, and speeded response procedures.

    Science.gov (United States)

    Horton, Keith D; Wilson, Daryl E; Vonk, Jennifer; Kirby, Sarah L; Nielsen, Tina

    2005-07-01

    Using the stem completion task, we compared estimates of automatic retrieval from an implicit memory task, the process dissociation procedure, and the speeded response procedure. Two standard manipulations were employed. In Experiment 1, a depth of processing effect was found on automatic retrieval using the speeded response procedure although this effect was substantially reduced in Experiment 2 when lexical processing was required of all words. In Experiment 3, the speeded response procedure showed an advantage of full versus divided attention at study on automatic retrieval. An implicit condition showed parallel effects in each study, suggesting that implicit stem completion may normally provide a good estimate of automatic retrieval. Also, we replicated earlier findings from the process dissociation procedure, but estimates of automatic retrieval from this procedure were consistently lower than those from the speeded response procedure, except when conscious retrieval was relatively low. We discuss several factors that may contribute to the conflicting outcomes, including the evidence for theoretical assumptions and criterial task differences between implicit and explicit tests.

  5. EPA perspective on radionuclide aerosol sampling

    Energy Technology Data Exchange (ETDEWEB)

    Karhnak, J.M. [Environmental Protection Agency, Washington, DC (United States)

    1995-02-01

    The Environmental Protection Agency (EPA) is concerned with radionuclide aerosol sampling primarily at Department of Energy (DOE) facilities in order to insure compliance with national air emission standards, known as NESHAPs. Sampling procedures are specified in {open_quotes}National Emission Standards for Emissions of Radionuclides other than Radon from Department of Energy Sites{close_quotes} (Subpart H). Subpart H also allows alternate procedures to be used if they meet certain requirements. This paper discusses some of the mission differences between EPA and Doe and how these differences are reflected in decisions that are made. It then describes how the EPA develops standards, considers alternate sampling procedures, and lists suggestions to speed up the review and acceptance process for alternate procedures. The paper concludes with a discussion of the process for delegation of Radionuclide NESHAPs responsibilities to the States, and responsibilities that could be retained by EPA.

  6. Rapid DNA analysis for automated processing and interpretation of low DNA content samples.

    Science.gov (United States)

    Turingan, Rosemary S; Vasantgadkar, Sameer; Palombo, Luke; Hogan, Catherine; Jiang, Hua; Tan, Eugene; Selden, Richard F

    2016-01-01

    Short tandem repeat (STR) analysis of casework samples with low DNA content include those resulting from the transfer of epithelial cells from the skin to an object (e.g., cells on a water bottle, or brim of a cap), blood spatter stains, and small bone and tissue fragments. Low DNA content (LDC) samples are important in a wide range of settings, including disaster response teams to assist in victim identification and family reunification, military operations to identify friend or foe, criminal forensics to identify suspects and exonerate the innocent, and medical examiner and coroner offices to identify missing persons. Processing LDC samples requires experienced laboratory personnel, isolated workstations, and sophisticated equipment, requires transport time, and involves complex procedures. We present a rapid DNA analysis system designed specifically to generate STR profiles from LDC samples in field-forward settings by non-technical operators. By performing STR in the field, close to the site of collection, rapid DNA analysis has the potential to increase throughput and to provide actionable information in real time. A Low DNA Content BioChipSet (LDC BCS) was developed and manufactured by injection molding. It was designed to function in the fully integrated Accelerated Nuclear DNA Equipment (ANDE) instrument previously designed for analysis of buccal swab and other high DNA content samples (Investigative Genet. 4(1):1-15, 2013). The LDC BCS performs efficient DNA purification followed by microfluidic ultrafiltration of the purified DNA, maximizing the quantity of DNA available for subsequent amplification and electrophoretic separation and detection of amplified fragments. The system demonstrates accuracy, precision, resolution, signal strength, and peak height ratios appropriate for casework analysis. The LDC rapid DNA analysis system is effective for the generation of STR profiles from a wide range of sample types. The technology broadens the range of sample

  7. Operability test procedure for the Rotary Mode Core Sampling System Exhausters 3 and 4

    International Nuclear Information System (INIS)

    WSaldo, E.J.

    1995-01-01

    This document provides a procedure for performing operability testing of the Rotary Mode Core Sampling System Exhausters 3 ampersand 4. Upon completion of testing activities an operability testing report will be issued

  8. A new formulation of the linear sampling method: spatial resolution and post-processing

    International Nuclear Information System (INIS)

    Piana, M; Aramini, R; Brignone, M; Coyle, J

    2008-01-01

    A new formulation of the linear sampling method is described, which requires the regularized solution of a single functional equation set in a direct sum of L 2 spaces. This new approach presents the following notable advantages: it is computationally more effective than the traditional implementation, since time consuming samplings of the Tikhonov minimum problem and of the generalized discrepancy equation are avoided; it allows a quantitative estimate of the spatial resolution achievable by the method; it facilitates a post-processing procedure for the optimal selection of the scatterer profile by means of edge detection techniques. The formulation is described in a two-dimensional framework and in the case of obstacle scattering, although generalizations to three dimensions and penetrable inhomogeneities are straightforward

  9. Remote sampling of process fluids in radiochemical plants

    International Nuclear Information System (INIS)

    Sengar, P.B.; Bhattacharya, R.; Ozarde, P. D.; Rana, D.S.

    1990-01-01

    Sampling of process fluids, continuous or periodic, is an essential requirement in any chemical process plant, so as to keep a control on process variables. In a radiochemical plant the task of taking and conveying the samples is a very tricky affair. This is due to the fact that neither the vessels/equipment containing radioactive effluents can be approached for manual sampling nor sampled fluids can be handled directly. The problems become more accute with higher levels of radioactivity. As such, inovative systems have to be devised to obtain and handle the raioactive samples employing remote operations. The remote sampling system developed in this Division has some of the unique features such as taking only requisite amount of samples in microlitre range, practically maintenance free design, avoidence of excess radioactive fluids coming out of process systems, etc. The paper describes in detail the design of remote sampling system and compares the same with existing systems. The design efforts are towards simplicity in operation, obtaining homogenised representative samples and highly economical on man-rem expenditure. The performance of a prototype system has also been evaluated. (author). 3 refs

  10. Procedure Improvement in Blood Processing for Chromosome Aberration Analyst

    International Nuclear Information System (INIS)

    Noraisyah Mohd Yusof; Juliana Mahamad; Rahimah Abd Rahim; Yahaya Talib; Mohd Rodzi Ali

    2015-01-01

    Detection of chromosome at metaphase of the cell cycle is performed either manually or automatically. Procedure for slide preparation published by the IAEA does not guarantee that the quality of slide is suitable for automatic detection. The detection efficiency reduces if there is cells debris on slides. This paper describes the modifications made to the standard procedure. The period of hypotonic treatment to the cell was lengthened; the slides were pre-treated with RNase and the frequency of rinsing during the chromosomal coloring process was increased. Results show the metaphase images were better and clearer, and numbers of metaphase that can be detected automatically were also increased. In conclusion, modification to the current standard protocol helps to easy the process of chromosome aberration analysis at Nuclear Malaysia. (author)

  11. Study on different pre-treatment procedures for metal determination in Orujo spirit samples by ICP-AES

    International Nuclear Information System (INIS)

    Barciela, Julia; Vilar, Manuela; Garcia-Martin, Sagrario; Pena, Rosa M.; Herrero, Carlos

    2008-01-01

    In this work several pre-treatment methods were studied for metal (Na, K, Mg, Cu and Ca) determination in Orujo spirit samples using inductively coupled plasma atomic emission spectrometry (ICP-AES). Dilution, digestion, evaporation, and cryogenic desolvatation techniques were comparatively evaluated. Because of their analytical characteristics, digestion and evaporation with nitrogen current were found to be appropriate procedures for the determination of metals in alcoholic spirit samples. Yet, if simplicity and application time are to be considered, the latter-evaporation in a water bath with a nitrogen current-stands out as the optimum procedure for any further determinations in Orujo samples by ICP-AES. Low detection levels and wide linear ranges (sufficient to determine these metals in the samples studied) were achieved for each metal. The recoveries (in the 97.5-100.5% range) and the precision (R.S.D. lower than 5.6%) obtained were also satisfactory. The selected procedure was applied to determine the content of metals in 80 representative Galician Orujo spirit samples with and without a Certified Brand of Origin (CBO) which had been produced using different distillation systems. The metal concentrations ranged between 0.37 and 79.7 mg L -1 for Na, -1 for K, 0.02-4.83 mg L -1 for Mg content, -1 for Cu and 0.03-13.10 mg L -1 for Ca

  12. RECOMMENDED OPERATING PROCEDURE NO. 56: COLLECTION OF GASEOUS GRAB SAMPLES FROM COMBUSTION SOURCES FOR NITROUS OXIDE MEASUREMENT

    Science.gov (United States)

    The document is a recommended operating procedure, prepare or use in research activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). The procedure applies to the collection of gaseous grab samples from fossil fuel combustion sources for subsequent a...

  13. Metallization and photolithographic processes and procedures for MC2730 RTG thermopile intraconnections

    International Nuclear Information System (INIS)

    Komarek, E.E.; Wright, R.E.; Knauss, G.L.

    1974-03-01

    Processes and procedures were developed for applying the thin film tungsten electrical intraconnections to the MC2730 RTG ''one-dimensional'' thermopile. After polishing, the surface to be metallized was cleaned with a detergent/organic solvent procedure and then etched with hydrofluoric acid to minimize the oxide. Tungsten contacts were sputtered onto the thermopile and the individual contacts photolithographically defined using a negative acting photoresist in conjunction with a potassium ferricyanide etchant. The processes were used to process 89 thermopiles with an 80 percent effective yield

  14. New experimental procedure for measuring volume magnetostriction on powder samples

    International Nuclear Information System (INIS)

    Rivero, G.; Multigner, M.; Valdes, J.; Crespo, P.; Martinez, A.; Hernando, A.

    2005-01-01

    Conventional techniques used for volume magnetostriction measurements, as strain gauge or cantilever method, are very useful for ribbons or thin films but cannot be applied when the samples are in powder form. To overcome this problem a new experimental procedure has been developed. In this work, the experimental set-up is described, together with the results obtained in amorphous FeCuZr powders, which exhibit a strong dependence of the magnetization on the strength of the applied magnetic field. The magnetostriction measurements presented in this work point out that this dependence is related to a magnetovolume effect

  15. Influence of Freezing and Storage Procedure on Human Urine Samples in NMR-Based Metabolomics

    OpenAIRE

    Rist, Manuela; Muhle-Goll, Claudia; Görling, Benjamin; Bub, Achim; Heissler, Stefan; Watzl, Bernhard; Luy, Burkhard

    2013-01-01

    It is consensus in the metabolomics community that standardized protocols should be followed for sample handling, storage and analysis, as it is of utmost importance to maintain constant measurement conditions to identify subtle biological differences. The aim of this work, therefore, was to systematically investigate the influence of freezing procedures and storage temperatures and their effect on NMR spectra as a potentially disturbing aspect for NMR-based metabolomics studies. Urine sample...

  16. Disc valve for sampling erosive process streams

    Science.gov (United States)

    Mrochek, J.E.; Dinsmore, S.R.; Chandler, E.W.

    1986-01-07

    A four-port disc valve is described for sampling erosive, high temperature process streams. A rotatable disc defining opposed first and second sampling cavities rotates between fired faceplates defining flow passageways positioned to be alternatively in axial alignment with the first and second cavities. Silicon carbide inserts and liners composed of [alpha] silicon carbide are provided in the faceplates and in the sampling cavities to limit erosion while providing lubricity for a smooth and precise operation when used under harsh process conditions. 1 fig.

  17. a Novel Image Acquisition and Processing Procedure for Fast Tunnel Dsm Production

    Science.gov (United States)

    Roncella, R.; Umili, G.; Forlani, G.

    2012-07-01

    In mining operations the evaluation of the stability condition of the excavated front are critic to ensure a safe and correct planning of the subsequent activities. The procedure currently used to this aim has some shortcomings: safety for the geologist, completeness of data collection and objective documentation of the results. In the last decade it has been shown that the geostructural parameters necessary to the stability analysis can be derived from high resolution digital surface models (DSM) of rock faces. With the objective to overcome the limitation of the traditional survey and to minimize data capture times, so reducing delays on mining site operations, a photogrammetric system to generate high resolution DSM of tunnels has been realized. A fast, effective and complete data capture method has been developed and the orientation and restitution phases have been largely automated. The survey operations take no more than required to the traditional ones; no additional topographic measurements other than those available are required. To make the data processing fast and economic our Structure from Motion procedure has been slightly modified to adapt to the peculiar block geometry while, the DSM of the tunnel is created using automatic image correlation techniques. The geomechanical data are sampled on the DSM, by using the acquired images in a GUI and a segmentation procedure to select discontinuity planes. To allow an easier and faster identification of relevant features of the surface of the tunnel, using again an automatic procedure, an orthophoto of the tunnel is produced. A case study where a tunnel section of ca. 130 m has been surveyed is presented.

  18. A NOVEL IMAGE ACQUISITION AND PROCESSING PROCEDURE FOR FAST TUNNEL DSM PRODUCTION

    Directory of Open Access Journals (Sweden)

    R. Roncella

    2012-07-01

    Full Text Available In mining operations the evaluation of the stability condition of the excavated front are critic to ensure a safe and correct planning of the subsequent activities. The procedure currently used to this aim has some shortcomings: safety for the geologist, completeness of data collection and objective documentation of the results. In the last decade it has been shown that the geostructural parameters necessary to the stability analysis can be derived from high resolution digital surface models (DSM of rock faces. With the objective to overcome the limitation of the traditional survey and to minimize data capture times, so reducing delays on mining site operations, a photogrammetric system to generate high resolution DSM of tunnels has been realized. A fast, effective and complete data capture method has been developed and the orientation and restitution phases have been largely automated. The survey operations take no more than required to the traditional ones; no additional topographic measurements other than those available are required. To make the data processing fast and economic our Structure from Motion procedure has been slightly modified to adapt to the peculiar block geometry while, the DSM of the tunnel is created using automatic image correlation techniques. The geomechanical data are sampled on the DSM, by using the acquired images in a GUI and a segmentation procedure to select discontinuity planes. To allow an easier and faster identification of relevant features of the surface of the tunnel, using again an automatic procedure, an orthophoto of the tunnel is produced. A case study where a tunnel section of ca. 130 m has been surveyed is presented.

  19. Procedural justice in wind facility siting: Recommendations for state-led siting processes

    International Nuclear Information System (INIS)

    Ottinger, Gwen; Hargrave, Timothy J.; Hopson, Eric

    2014-01-01

    Evidence suggests that state control of wind facility siting decisions fosters new project development more effectively than local control, yet the literature suggests that affected citizens tend to be more fairly represented in local siting processes. We argue that successful renewable energy policy must satisfy both the need for new project development and the obligation to procedural justice. To suggest how it can do so, we analyze existing state- and county-level siting processes in Washington state, finding that both fall short on measures of procedural justice. To overcome this limitation and address the tension between procedural justice and project development, we then propose a collaborative governance approach to wind facility siting, in which state governments retain ultimate authority over permitting decisions but encourage and support local-level deliberations as the primary means of making those decisions. Such an approach, we argue, would be more just, facilitate wind development by addressing community concerns constructively and result in better projects through the input of diverse stakeholders. - Highlights: • States have made wind energy development a priority. • Local opposition to new projects could hinder future wind energy development. • Procedural justice is necessary to resolve local issues and ensure timely wind facility siting. • Both state- and county-led siting processes fall short with respect to criteria for procedural justice, though local processes have some advantages. • States could instead induce counties, developers to engage in deliberation

  20. Study on different pre-treatment procedures for metal determination in Orujo spirit samples by ICP-AES

    Energy Technology Data Exchange (ETDEWEB)

    Barciela, Julia; Vilar, Manuela; Garcia-Martin, Sagrario [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain); Pena, Rosa M. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain)], E-mail: qarosa@lugo.usc.es; Herrero, Carlos [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain)], E-mail: cherrero@lugo.usc.es

    2008-10-17

    In this work several pre-treatment methods were studied for metal (Na, K, Mg, Cu and Ca) determination in Orujo spirit samples using inductively coupled plasma atomic emission spectrometry (ICP-AES). Dilution, digestion, evaporation, and cryogenic desolvatation techniques were comparatively evaluated. Because of their analytical characteristics, digestion and evaporation with nitrogen current were found to be appropriate procedures for the determination of metals in alcoholic spirit samples. Yet, if simplicity and application time are to be considered, the latter-evaporation in a water bath with a nitrogen current-stands out as the optimum procedure for any further determinations in Orujo samples by ICP-AES. Low detection levels and wide linear ranges (sufficient to determine these metals in the samples studied) were achieved for each metal. The recoveries (in the 97.5-100.5% range) and the precision (R.S.D. lower than 5.6%) obtained were also satisfactory. The selected procedure was applied to determine the content of metals in 80 representative Galician Orujo spirit samples with and without a Certified Brand of Origin (CBO) which had been produced using different distillation systems. The metal concentrations ranged between 0.37 and 79.7 mg L{sup -1} for Na,

  1. Examining procedural working memory processing in obsessive-compulsive disorder.

    Science.gov (United States)

    Shahar, Nitzan; Teodorescu, Andrei R; Anholt, Gideon E; Karmon-Presser, Anat; Meiran, Nachshon

    2017-07-01

    Previous research has suggested that a deficit in working memory might underlie the difficulty of obsessive-compulsive disorder (OCD) patients to control their thoughts and actions. However, a recent meta-analyses found only small effect sizes for working memory deficits in OCD. Recently, a distinction has been made between declarative and procedural working memory. Working memory in OCD was tested mostly using declarative measurements. However, OCD symptoms typically concerns actions, making procedural working-memory more relevant. Here, we tested the operation of procedural working memory in OCD. Participants with OCD and healthy controls performed a battery of choice reaction tasks under high and low procedural working memory demands. Reaction-times (RT) were estimated using ex-Gaussian distribution fitting, revealing no group differences in the size of the RT distribution tail (i.e., τ parameter), known to be sensitive to procedural working memory manipulations. Group differences, unrelated to working memory manipulations, were found in the leading-edge of the RT distribution and analyzed using a two-stage evidence accumulation model. Modeling results suggested that perceptual difficulties might underlie the current group differences. In conclusion, our results suggest that procedural working-memory processing is most likely intact in OCD, and raise a novel, yet untested assumption regarding perceptual deficits in OCD. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  2. The MacDonald and savage titrimetric procedure for plutonium scaled-down to the milligram level: Automated procedure for routine analysis of safeguards samples containing 2 to 5 mg plutonium

    International Nuclear Information System (INIS)

    Ronesch, K.; Jammet, G.; Berger, J.; Doubek, N.; Bagliano, G.; Deron, S.

    1992-08-01

    A selective titrimetric procedure directly applicable to both input and product solutions from fast reactor fuel reprocessing was set up by MacDonald and Savage and scaled down to 3 mg of plutonium in sample aliquots at the request of the Safeguards Analytical Laboratory (SAL) of the International Atomic Energy Agency (IAEA), which needed to replace its silver (II) oxide titration procedure by a more selective electrochemical method. Although the procedure is very selective the following species still interfere: Vanadates (almost quantitatively), Neptunium (one electron exchange per mole); Nitrites, Fluorosilicates and Iodates present in mg amount yield slight biases. This paper describes the fully automatized procedure presently applied in SAL for the routine determination of 2 to 5 mg plutonium dissolved in nitric acid solution. The method allows the unattended analysis of 20 aliquots within a five hour period. The equipment including the reagent distribution system, the sample changer and the control units are introduced and the principle design of the software is shortly described. Safety requirements have been addressed and are also reviewed in the report. Results obtained on standard reference materials, international intercomparison samples and actual safeguards samples routinely analyzed with the proposed procedure are presented and compared with results achieved with the semiautomatic mode to demonstrate the performance. International requirements to reduce the amount of radioactive materials in waste will certainly lead to a further reduction of the amount of plutonium in one aliquot. Some future perspective to titrate 1 mg samples are presented in the discussion. 12 refs, 10 figs, 8 tabs

  3. Reforming Scottish Criminal Procedure: In Search of Process Values

    Directory of Open Access Journals (Sweden)

    Pamela R. Ferguson

    2017-01-01

    Full Text Available Recent proposals to reform Scottish criminal procedure are motivated by considerations of efficiency and accurate fact-finding, and there is little attempt to offer a normative account. This paper describes these proposals and contends that their emphasis on finding ‘the truth’ is misplaced on two distinct bases: (1 it equates erroneous acquittals to wrongful convictions, thus fails to uphold a fundamental tenet of criminal procedure, namely the particular importance of protecting the innocent against wrongful conviction; and (2 it fails to recognise the importance of non-instrumental process values which are at the heart of the adversarial criminal trial.  The paper suggests that it is only by adhering to these process values that the state maintains – and demonstrates that it maintains – its moral authority to condemn and punish offenders. Key notes: Return Directive, entry ban, illegal migrant, criminal law sanctions, crimmigration, expulsion.

  4. The Macdonald and Savage titrimetric procedure scaled down to 4 mg sized plutonium samples. P. 1

    International Nuclear Information System (INIS)

    Kuvik, V.; Lecouteux, C.; Doubek, N.; Ronesch, K.; Jammet, G.; Bagliano, G.; Deron, S.

    1992-01-01

    The original Macdonald and Savage amperometric method scaled down to milligram-sized plutonium samples was further modified. The electro-chemical process of each redox step and the end-point of the final titration were monitored potentiometrically. The method is designed to determine 4 mg of plutonium dissolved in nitric acid solution. It is suitable for the direct determination of plutonium in non-irradiated fuel with a uranium-to-plutonium ratio of up to 30. The precision and accuracy are ca. 0.05-0.1% (relative standard deviation). Although the procedure is very selective, the following species interfere: vanadyl(IV) and vanadate (almost quantitatively), neptunium (one electron exchange per mole), nitrites, fluorosilicates (milligram amounts yield a slight bias) and iodates. (author). 15 refs.; 8 figs.; 7 tabs

  5. A procedure for the rapid determination of Pu isotopes and Am-241 in soil and sediment samples by alpha spectrometry

    International Nuclear Information System (INIS)

    2009-01-01

    Reliable, comparable and 'fit for purpose' results are an essential requirement for any decision based on analytical measurements. For the analyst, the availability of tested and validated analytical procedures is a extremely important tool for production of such analytical measurements. For maximum utility, such procedures should be comprehensive, clearly formulated, and readily available to both the analyst and the customer for reference. Since 2004 the Environment Programme of the IAEA has included activities aimed at the development of a set of procedures for the determination of radionuclides in terrestrial environmental samples. In this report, a rapid procedure for the determination of Pu and Am radionuclides in soil and sediment samples is described that can be used in emergency situations. The method provides accurate and reliable results for the activity concentrations of elevated levels of 239,240 Pu, 238 Pu and 241 Am in soil and sediment samples over the course of 24 hours. The procedure has been validated in accordance with ISO guidelines

  6. Configural and component processing in simultaneous and sequential lineup procedures

    OpenAIRE

    Flowe, HD; Smith, HMJ; Karoğlu, N; Onwuegbusi, TO; Rai, L

    2015-01-01

    Configural processing supports accurate face recognition, yet it has never been examined within the context of criminal identification lineups. We tested, using the inversion paradigm, the role of configural processing in lineups. Recent research has found that face discrimination accuracy in lineups is better in a simultaneous compared to a sequential lineup procedure. Therefore, we compared configural processing in simultaneous and sequential lineups to examine whether there are differences...

  7. Inferring the demographic history from DNA sequences: An importance sampling approach based on non-homogeneous processes.

    Science.gov (United States)

    Ait Kaci Azzou, S; Larribe, F; Froda, S

    2016-10-01

    In Ait Kaci Azzou et al. (2015) we introduced an Importance Sampling (IS) approach for estimating the demographic history of a sample of DNA sequences, the skywis plot. More precisely, we proposed a new nonparametric estimate of a population size that changes over time. We showed on simulated data that the skywis plot can work well in typical situations where the effective population size does not undergo very steep changes. In this paper, we introduce an iterative procedure which extends the previous method and gives good estimates under such rapid variations. In the iterative calibrated skywis plot we approximate the effective population size by a piecewise constant function, whose values are re-estimated at each step. These piecewise constant functions are used to generate the waiting times of non homogeneous Poisson processes related to a coalescent process with mutation under a variable population size model. Moreover, the present IS procedure is based on a modified version of the Stephens and Donnelly (2000) proposal distribution. Finally, we apply the iterative calibrated skywis plot method to a simulated data set from a rapidly expanding exponential model, and we show that the method based on this new IS strategy correctly reconstructs the demographic history. Copyright © 2016. Published by Elsevier Inc.

  8. Investigation of strong motion processing procedures

    International Nuclear Information System (INIS)

    Rinaldi, D.; Goula, X.; Menu, J.M.

    1988-03-01

    The work which is described here presents preliminary results of an on-going research relating to the accurate recording and quality processing of earthquake strong ground motions. The work is the product of a tripartite co-operation between three European Centres (ENEA, PAS-ISP Laboratorio Ingengneria dei Siti, Rome/CEA, IPSN, Fontenay-aux-Roses, ICST, Department of Civil Engineering, London), which have carried out independently similar research in the recent past. Other European Institutes joined the three mentioned organizations for discussions during a Workshop (June 1985) held in Casaccia (ENEA Research Centre of Rome). The aim of the research is a thorough analysis of various factors affecting the recovery of true ground accelerations recorded with analogue instruments. The separate and cumulative effects of the type of recording accelerometer, the digitization equipment and the correction routines have been analysed. Global comparisons have been achieved to obtain a general insight into various standard processing procedures

  9. X-Ray Computed Tomography: The First Step in Mars Sample Return Processing

    Science.gov (United States)

    Welzenbach, L. C.; Fries, M. D.; Grady, M. M.; Greenwood, R. C.; McCubbin, F. M.; Zeigler, R. A.; Smith, C. L.; Steele, A.

    2017-01-01

    The Mars 2020 rover mission will collect and cache samples from the martian surface for possible retrieval and subsequent return to Earth. If the samples are returned, that mission would likely present an opportunity to analyze returned Mars samples within a geologic context on Mars. In addition, it may provide definitive information about the existence of past or present life on Mars. Mars sample return presents unique challenges for the collection, containment, transport, curation and processing of samples [1] Foremost in the processing of returned samples are the closely paired considerations of life detection and Planetary Protection. In order to achieve Mars Sample Return (MSR) science goals, reliable analyses will depend on overcoming some challenging signal/noise-related issues where sparse martian organic compounds must be reliably analyzed against the contamination background. While reliable analyses will depend on initial clean acquisition and robust documentation of all aspects of developing and managing the cache [2], there needs to be a reliable sample handling and analysis procedure that accounts for a variety of materials which may or may not contain evidence of past or present martian life. A recent report [3] suggests that a defined set of measurements should be made to effectively inform both science and Planetary Protection, when applied in the context of the two competing null hypotheses: 1) that there is no detectable life in the samples; or 2) that there is martian life in the samples. The defined measurements would include a phased approach that would be accepted by the community to preserve the bulk of the material, but provide unambiguous science data that can be used and interpreted by various disciplines. Fore-most is the concern that the initial steps would ensure the pristine nature of the samples. Preliminary, non-invasive techniques such as computed X-ray tomography (XCT) have been suggested as the first method to interrogate and

  10. A DATABASE FOR TRACKING TOXICOGENOMIC SAMPLES AND PROCEDURES WITH GENOMIC, PROTEOMIC AND METABONOMIC COMPONENTS

    Science.gov (United States)

    A Database for Tracking Toxicogenomic Samples and Procedures with Genomic, Proteomic and Metabonomic Components Wenjun Bao1, Jennifer Fostel2, Michael D. Waters2, B. Alex Merrick2, Drew Ekman3, Mitchell Kostich4, Judith Schmid1, David Dix1Office of Research and Developmen...

  11. Evaluation of six sample preparation procedures for qualitative and quantitative proteomics analysis of milk fat globule membrane.

    Science.gov (United States)

    Yang, Yongxin; Anderson, Elizabeth; Zhang, Sheng

    2018-04-12

    Proteomic analysis of membrane proteins is challenged by the proteins solubility and detergent incompatibility with MS analysis. No single perfect protocol can be used to comprehensively characterize the proteome of membrane fraction. Here, we used cow milk fat globule membrane (MFGM) proteome analysis to assess six sample preparation procedures including one in-gel and five in-solution digestion approaches prior to LC-MS/MS analysis. The largest number of MFGM proteins were identified by suspension trapping (S-Trap) and filter-aided sample preparation (FASP) methods, followed by acetone precipitation without clean-up of tryptic peptides method. Protein identifications with highest average coverage was achieved by Chloroform/MeOH, in-gel and S-Trap methods. Most distinct proteins were identified by FASP method, followed by S-Trap. Analyses by Venn diagram, principal-component analysis, hierarchical clustering and the abundance ranking of quantitative proteins highlight differences in the MFGM fraction by the all sample preparation procedures. These results reveal the biased proteins/peptides loss occurred in each protocol. In this study, we found several novel proteins that were not observed previously by in-depth proteomics characterization of MFGM fraction in milk. Thus, a combination of multiple procedures with orthologous properties of sample preparation was demonstrated to improve the protein sequence coverage and expression level accuracy of membrane samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. A sensitive analytical procedure for monitoring acrylamide in environmental water samples by offline SPE-UPLC/MS/MS.

    Science.gov (United States)

    Togola, Anne; Coureau, Charlotte; Guezennec, Anne-Gwenaëlle; Touzé, Solène

    2015-05-01

    The presence of acrylamide in natural systems is of concern from both environmental and health points of view. We developed an accurate and robust analytical procedure (offline solid phase extraction combined with UPLC/MS/MS) with a limit of quantification (20 ng L(-1)) compatible with toxicity threshold values. The optimized (considering the nature of extraction phases, sampling volumes, and solvent of elution) solid phase extraction (SPE) was validated according to ISO Standard ISO/IEC 17025 on groundwater, surface water, and industrial process water samples. Acrylamide is highly polar, which induces a high variability during the SPE step, therefore requiring the use of C(13)-labeled acrylamide as an internal standard to guarantee the accuracy and robustness of the method (uncertainty about 25 % (k = 2) at limit of quantification level). The specificity of the method and the stability of acrylamide were studied for these environmental media, and it was shown that the method is suitable for measuring acrylamide in environmental studies.

  13. 14CO2 analysis of soil gas: Evaluation of sample size limits and sampling devices

    Science.gov (United States)

    Wotte, Anja; Wischhöfer, Philipp; Wacker, Lukas; Rethemeyer, Janet

    2017-12-01

    Radiocarbon (14C) analysis of CO2 respired from soils or sediments is a valuable tool to identify different carbon sources. The collection and processing of the CO2, however, is challenging and prone to contamination. We thus continuously improve our handling procedures and present a refined method for the collection of even small amounts of CO2 in molecular sieve cartridges (MSCs) for accelerator mass spectrometry 14C analysis. Using a modified vacuum rig and an improved desorption procedure, we were able to increase the CO2 recovery from the MSC (95%) as well as the sample throughput compared to our previous study. By processing series of different sample size, we show that our MSCs can be used for CO2 samples of as small as 50 μg C. The contamination by exogenous carbon determined in these laboratory tests, was less than 2.0 μg C from fossil and less than 3.0 μg C from modern sources. Additionally, we tested two sampling devices for the collection of CO2 samples released from soils or sediments, including a respiration chamber and a depth sampler, which are connected to the MSC. We obtained a very promising, low process blank for the entire CO2 sampling and purification procedure of ∼0.004 F14C (equal to 44,000 yrs BP) and ∼0.003 F14C (equal to 47,000 yrs BP). In contrast to previous studies, we observed no isotopic fractionation towards lighter δ13C values during the passive sampling with the depth samplers.

  14. The effect of standard heat and filtration processing procedures on antimicrobial activity and hydrogen peroxide levels in honey.

    Science.gov (United States)

    Chen, Cuilan; Campbell, Leona T; Blair, Shona E; Carter, Dee A

    2012-01-01

    There is increasing interest in the antimicrobial properties of honey. In most honey types, antimicrobial activity is due to the generation of hydrogen peroxide (H(2)O(2)), but this can vary greatly among samples. Honey is a complex product and other components may modulate activity, which can be further affected by commercial processing procedures. In this study we examined honey derived from three native Australian floral sources that had previously been associated with H(2)O(2)-dependent activity. Antibacterial activity was seen in four red stringybark samples only, and ranged from 12 to 21.1% phenol equivalence against Staphylococcus aureus. Antifungal activity ranged from MIC values of 19-38.3% (w/v) against Candida albicans, and all samples were significantly more active than an osmotically equivalent sugar solution. All honey samples were provided unprocessed and following commercial processing. Processing was usually detrimental to antimicrobial activity, but occasionally the reverse was seen and activity increased. H(2)O(2) levels varied from 0 to 1017 μM, and although samples with no H(2)O(2) had little or no antimicrobial activity, some samples had relatively high H(2)O(2) levels yet no antimicrobial activity. In samples where H(2)O(2) was detected, the correlation with antibacterial activity was greater in the processed than in the unprocessed samples, suggesting other factors present in the honey influence this activity and are sensitive to heat treatment. Antifungal activity did not correlate with the level of H(2)O(2) in honey samples, and overall it appeared that H(2)O(2) alone was not sufficient to inhibit C. albicans. We conclude that floral source and H(2)O(2) levels are not reliable predictors of the antimicrobial activity of honey, which currently can only be assessed by standardized antimicrobial testing. Heat processing should be reduced where possible, and honey destined for medicinal use should be retested post-processing to ensure that

  15. Measurement of density distribution of a cracking catalyst in experimental riser with a sampling procedure for gamma ray tomography

    International Nuclear Information System (INIS)

    Dantas, C.C.; Melo, S.B.; Oliveira, E.F.; Simoes, F.P.M.; Santos, M.G. dos; Santos, V.A. dos

    2008-01-01

    By scanning a riser the number of the gamma ray trajectories and the beam width involve temporal, spatial and density resolutions as they are closely correlated parameters. Therefore, evaluation of parameters and their interaction quantification, certainly, are required in the imaging process. Measuring the density distribution of the catalyst from the FCC - fluid cracking catalytic process in an experimental riser in single beam tomographic system, density resolution is evaluated and correlated with spatial resolution. The beam width Δs inside riser is measured and a criterion for determining spatial resolution is proposed. Experiments are carried out to demonstrate resolution effects of three Δs values: 3.30 x 10 -3 , 6.20 x 10 -3 and 12.00 x 10 -3 m. The gamma beam profile is modeled and a sampling rate according to Nyquist criterion is analyzed. The 4.3%, 8.1% and 15.6% ratios of Δs/R to internal riser radius are correlated to counting time in the sampling procedure. Results are discussed by comparison with values from literature

  16. Recommended operating procedure number 56: Collection of gaseous grab samples from combustion sources for nitrous oxide measurement. Final report, Jan-Dec 91

    International Nuclear Information System (INIS)

    Ryan, J.V.; Karns, S.A.

    1992-07-01

    The document is a recommended operating procedure (ROP), prepared for use in research activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). The procedure applies to the collection of gaseous grab samples from fossil fuel combustion sources for subsequent analysis of nitrous oxide. The procedure details only the grab sampling methodology and associated equipment

  17. 9 CFR 318.305 - Equipment and procedures for heat processing systems.

    Science.gov (United States)

    2010-01-01

    ... processing systems. 318.305 Section 318.305 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE AGENCY ORGANIZATION AND TERMINOLOGY; MANDATORY MEAT AND POULTRY PRODUCTS INSPECTION... PREPARATION OF PRODUCTS Canning and Canned Products § 318.305 Equipment and procedures for heat processing...

  18. Asymptotically optimum multialternative sequential procedures for discernment of processes minimizing average length of observations

    Science.gov (United States)

    Fishman, M. M.

    1985-01-01

    The problem of multialternative sequential discernment of processes is formulated in terms of conditionally optimum procedures minimizing the average length of observations, without any probabilistic assumptions about any one occurring process, rather than in terms of Bayes procedures minimizing the average risk. The problem is to find the procedure that will transform inequalities into equalities. The problem is formulated for various models of signal observation and data processing: (1) discernment of signals from background interference by a multichannel system; (2) discernment of pulse sequences with unknown time delay; (3) discernment of harmonic signals with unknown frequency. An asymptotically optimum sequential procedure is constructed which compares the statistics of the likelihood ratio with the mean-weighted likelihood ratio and estimates the upper bound for conditional average lengths of observations. This procedure is shown to remain valid as the upper bound for the probability of erroneous partial solutions decreases approaching zero and the number of hypotheses increases approaching infinity. It also remains valid under certain special constraints on the probability such as a threshold. A comparison with a fixed-length procedure reveals that this sequential procedure decreases the length of observations to one quarter, on the average, when the probability of erroneous partial solutions is low.

  19. Adrenal venous sampling: the learning curve of a single interventionalist with 282 consecutive procedures.

    Science.gov (United States)

    Jakobsson, Hugo; Farmaki, Katerina; Sakinis, Augustinas; Ehn, Olof; Johannsson, Gudmundur; Ragnarsson, Oskar

    2018-01-01

    Primary aldosteronism (PA) is a common cause of secondary hypertension. Adrenal venous sampling (AVS) is the gold standard for assessing laterality of PA, which is of paramount importance to decide adequate treatment. AVS is a technically complicated procedure with success rates ranging between 30% and 96%. The aim of this study was to investigate the success rate of AVS over time, performed by a single interventionalist. This was a retrospective study based on consecutive AVS procedures performed by a single operator between September 2005 and June 2016. Data on serum concentrations of aldosterone and cortisol from right and left adrenal vein, inferior vena cava, and peripheral vein were collected and selectivity index (SI) calculated. Successful AVS was defined as SI > 5. In total, 282 AVS procedures were performed on 269 patients, 168 men (62%) and 101 women (38%), with a mean age of 55±11 years (range, 26-78 years). Out of 282 AVS procedures, 259 were successful, giving an overall success rate of 92%. The most common reason for failure was inability to localize the right adrenal vein (n=16; 76%). The success rates were 63%, 82%, and 94% during the first, second, and third years, respectively. During the last 8 years the success rate was 95%, and on average 27 procedures were performed annually. Satisfactory AVS success rate was achieved after approximately 36 procedures and satisfactory success rate was maintained by performing approximately 27 procedures annually. AVS should be limited to few operators that perform sufficiently large number of procedures to achieve, and maintain, satisfactory AVS success rate.

  20. Procedures for field chemical analyses of water samples

    International Nuclear Information System (INIS)

    Korte, N.; Ealey, D.

    1983-12-01

    A successful water-quality monitoring program requires a clear understanding of appropriate measurement procedures in order to obtain reliable field data. It is imperative that the responsible personnel have a thorough knowledge of the limitations of the techniques being used. Unfortunately, there is a belief that field analyses are simple and straightforward. Yet, significant controversy as well as misuse of common measurement techniques abounds. This document describes procedures for field measurements of pH, carbonate and bicarbonate, specific conductance, dissolved oxygen, nitrate, Eh, and uranium. Each procedure section includes an extensive discussion regarding the limitations of the method as well as brief discussions of calibration procedures and available equipment. A key feature of these procedures is the consideration given to the ultimate use of the data. For example, if the data are to be used for geochemical modeling, more precautions are needed. In contrast, routine monitoring conducted merely to recognize gross changes can be accomplished with less effort. Finally, quality assurance documentation for each measurement is addressed in detail. Particular attention is given to recording sufficient information such that decisions concerning the quality of the data can be easily made. Application of the procedures and recommendations presented in this document should result in a uniform and credible water-quality monitoring program. 22 references, 4 figures, 3 tables

  1. Sampling quality assurance guidance in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-05-01

    This document introduces quality assurance guidance pertaining to the design and implementation of sampling procedures and processes for collecting environmental data for DOE's Office of EM (Environmental Restoration and Waste Management)

  2. Non-Contact Conductivity Measurement for Automated Sample Processing Systems

    Science.gov (United States)

    Beegle, Luther W.; Kirby, James P.

    2012-01-01

    A new method has been developed for monitoring and control of automated sample processing and preparation especially focusing on desalting of samples before analytical analysis (described in more detail in Automated Desalting Apparatus, (NPO-45428), NASA Tech Briefs, Vol. 34, No. 8 (August 2010), page 44). The use of non-contact conductivity probes, one at the inlet and one at the outlet of the solid phase sample preparation media, allows monitoring of the process, and acts as a trigger for the start of the next step in the sequence (see figure). At each step of the muti-step process, the system is flushed with low-conductivity water, which sets the system back to an overall low-conductivity state. This measurement then triggers the next stage of sample processing protocols, and greatly minimizes use of consumables. In the case of amino acid sample preparation for desalting, the conductivity measurement will define three key conditions for the sample preparation process. First, when the system is neutralized (low conductivity, by washing with excess de-ionized water); second, when the system is acidified, by washing with a strong acid (high conductivity); and third, when the system is at a basic condition of high pH (high conductivity). Taken together, this non-contact conductivity measurement for monitoring sample preparation will not only facilitate automation of the sample preparation and processing, but will also act as a way to optimize the operational time and use of consumables

  3. Automated synthesis of image processing procedures using AI planning techniques

    Science.gov (United States)

    Chien, Steve; Mortensen, Helen

    1994-01-01

    This paper describes the Multimission VICAR (Video Image Communication and Retrieval) Planner (MVP) (Chien 1994) system, which uses artificial intelligence planning techniques (Iwasaki & Friedland, 1985, Pemberthy & Weld, 1992, Stefik, 1981) to automatically construct executable complex image processing procedures (using models of the smaller constituent image processing subprograms) in response to image processing requests made to the JPL Multimission Image Processing Laboratory (MIPL). The MVP system allows the user to specify the image processing requirements in terms of the various types of correction required. Given this information, MVP derives unspecified required processing steps and determines appropriate image processing programs and parameters to achieve the specified image processing goals. This information is output as an executable image processing program which can then be executed to fill the processing request.

  4. Optimization of organic contaminant and toxicity testing analytical procedures for estimating the characteristics and environmental significance of natural gas processing plant waste sludges

    International Nuclear Information System (INIS)

    Novak, N.

    1990-10-01

    The Gas Plant Sludge Characterization Phase IIB program is a continuation of the Canadian Petroleum Association's (CPA) initiatives to characterize sludge generated at gas processing plants. The objectives of the Phase IIB project were to develop an effective procedure for screening waste sludges or centrifuge/leachate generated from sludge samples for volatile, solvent-soluble and water-soluble organics; verify the reproducibility of the three aquatic toxicity tests recommended as the battery of tests for determining the environmental significance of sludge centrifugates or leachates; assess the performance of two terrestrial toxicity tests in determining the environmental significance of whole sludge samples applied to soil; and to assess and discuss the reproducibility and cost-effectiveness of the sampling and analytical techniques proposed for the overall sludge characterization procedure. Conclusions and recommendations are provided for sludge collection, preparation and distribution, organic analyses, toxicity testing, project management, and procedure standardization. The three aquatic and two terrestrial toxicity tests proved effective in indicating the toxicity of complex mixtures. 27 refs., 3 figs., 59 tabs

  5. Infrared thermometry and the crop water stress index. II. Sampling procedures and interpretation

    International Nuclear Information System (INIS)

    Gardner, B.R.; Nielsen, D.C.; Shock, C.C.

    1992-01-01

    Infrared thermometry can be a valuable research and production tool for detecting and quantifying water stress in plants, as shown by a large volume of published research. Users of infrared thermometers (IRT) should be aware of the many equipment, environmental, and plant factors influencing canopy temperature measured by an IRT. The purpose of this paper is to describe factors influencing measured plant temperature, outline sampling procedures that will produce reliable Crop Water Stress Index (CWSI) values, and offer interpretations of CWSI and plant temperatures relative to crop production and other water stress parameters by reviewing previously conducted research. Factors that are considered are IRT condition, configuration, and position; psychrometer location; wind speed; solar radiation; time of day; leaf area and orientation; and appropriate non-water-stressed baseline equation. Standard sampling and CWSI calculation procedures are proposed. Use of CWSI with crops varying in type of response to water stress is described. Previously conducted research on plant temperatures or CWSI is tabulated by crop and water stress parameters measured. The paper provides valuable information to assist interested users of IRTs in making reliable water stress measurements. (author)

  6. Infrared thermometry and the crop water stress index. II. Sampling procedures and interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Gardner, B. R. [BP Research, Cleveland, OH (United States); Nielsen, D. C.; Shock, C. C.

    1992-10-15

    Infrared thermometry can be a valuable research and production tool for detecting and quantifying water stress in plants, as shown by a large volume of published research. Users of infrared thermometers (IRT) should be aware of the many equipment, environmental, and plant factors influencing canopy temperature measured by an IRT. The purpose of this paper is to describe factors influencing measured plant temperature, outline sampling procedures that will produce reliable Crop Water Stress Index (CWSI) values, and offer interpretations of CWSI and plant temperatures relative to crop production and other water stress parameters by reviewing previously conducted research. Factors that are considered are IRT condition, configuration, and position; psychrometer location; wind speed; solar radiation; time of day; leaf area and orientation; and appropriate non-water-stressed baseline equation. Standard sampling and CWSI calculation procedures are proposed. Use of CWSI with crops varying in type of response to water stress is described. Previously conducted research on plant temperatures or CWSI is tabulated by crop and water stress parameters measured. The paper provides valuable information to assist interested users of IRTs in making reliable water stress measurements. (author)

  7. 40 CFR 761.283 - Determination of the number of samples to collect and sample collection locations.

    Science.gov (United States)

    2010-07-01

    ...) MANUFACTURING, PROCESSING, DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS Sampling To Verify Completion of Self... cleanup verification conducted in accordance with § 761.61(a)(6), follow the procedures in paragraph (b... verification conducted in accordance with § 761.61(a)(6), follow the procedures in this section for locating...

  8. Quality evaluation of processed clay soil samples.

    Science.gov (United States)

    Steiner-Asiedu, Matilda; Harrison, Obed Akwaa; Vuvor, Frederick; Tano-Debrah, Kwaku

    2016-01-01

    This study assessed the microbial quality of clay samples sold on two of the major Ghanaian markets. The study was a cross-sectional assessing the evaluation of processed clay and effects it has on the nutrition of the consumers in the political capital town of Ghana. The items for the examination was processed clay soil samples. Staphylococcus spp and fecal coliforms including Klebsiella, Escherichia, and Shigella and Enterobacterspp were isolated from the clay samples. Samples from the Kaneshie market in Accra recorded the highest total viable counts 6.5 Log cfu/g and Staphylococcal count 5.8 Log cfu/g. For fecal coliforms, Madina market samples had the highest count 6.5 Log cfu/g and also recorded the highest levels of yeast and mould. For Koforidua, total viable count was highest in the samples from the Zongo market 6.3 Log cfu/g. Central market samples had the highest count of fecal coliforms 4.6 Log cfu/g and yeasts and moulds 6.5 Log cfu/g. "Small" market recorded the highest staphylococcal count 6.2 Log cfu/g. The water activity of the clay samples were low, and ranged between 0.65±0.01 and 0.66±0.00 for samples collected from Koforidua and Accra respectively. The clay samples were found to contain Klebsiella spp. Escherichia, Enterobacter, Shigella spp. staphylococcus spp., yeast and mould. These have health implications when consumed.

  9. Standard operating procedures for collection of soil and sediment samples for the Sediment-bound Contaminant Resiliency and Response (SCoRR) strategy pilot study

    Science.gov (United States)

    Fisher, Shawn C.; Reilly, Timothy J.; Jones, Daniel K.; Benzel, William M.; Griffin, Dale W.; Loftin, Keith A.; Iwanowicz, Luke R.; Cohl, Jonathan A.

    2015-12-17

    An understanding of the effects on human and ecological health brought by major coastal storms or flooding events is typically limited because of a lack of regionally consistent baseline and trends data in locations proximal to potential contaminant sources and mitigation activities, sensitive ecosystems, and recreational facilities where exposures are probable. In an attempt to close this gap, the U.S. Geological Survey (USGS) has implemented the Sediment-bound Contaminant Resiliency and Response (SCoRR) strategy pilot study to collect regional sediment-quality data prior to and in response to future coastal storms. The standard operating procedure (SOP) detailed in this document serves as the sample-collection protocol for the SCoRR strategy by providing step-by-step instructions for site preparation, sample collection and processing, and shipping of soil and surficial sediment (for example, bed sediment, marsh sediment, or beach material). The objectives of the SCoRR strategy pilot study are (1) to create a baseline of soil-, sand-, marsh sediment-, and bed-sediment-quality data from sites located in the coastal counties from Maine to Virginia based on their potential risk of being contaminated in the event of a major coastal storm or flooding (defined as Resiliency mode); and (2) respond to major coastal storms and flooding by reoccupying select baseline sites and sampling within days of the event (defined as Response mode). For both modes, samples are collected in a consistent manner to minimize bias and maximize quality control by ensuring that all sampling personnel across the region collect, document, and process soil and sediment samples following the procedures outlined in this SOP. Samples are analyzed using four USGS-developed screening methods—inorganic geochemistry, organic geochemistry, pathogens, and biological assays—which are also outlined in this SOP. Because the SCoRR strategy employs a multi-metric approach for sample analyses, this

  10. Comparative evaluation of the US Environmental Protection Agency's and the Oak Ridge Institute for Science and Education's environmental survey and site assessment program field sampling procedures

    International Nuclear Information System (INIS)

    Vitkus, T.J.; Bright, T.L.; Roberts, S.A.

    1997-10-01

    At the request of the U.S. Nuclear Regulatory Commission's (NRC's) Headquarters Office, the Environmental Survey and Site Assessment Program (ESSAP) of the Oak Ridge Institute for Science and Education (ORISE) compared the documented procedures that the U.S. Environmental Protection Agency (EPA) and ESSAP use for collecting environmental samples. The project objectives were to review both organizations' procedures applicable to collecting various sample matrices, compare the procedures for similarities and differences, and then to evaluate the reason for any identified procedural differences and their potential impact on ESSAP's sample data quality. The procedures reviewed included those for sampling surface and subsurface soil, surface and groundwater, vegetation, air, and removable surface contamination. ESSAP obtained copies of relevant EPA documents and reviewed and prepared a tabulated summary of each applicable procedure. The methods for collecting and handling each type of sample were evaluated for differences, and where these were identified, the significance and effect of the differences on analytical quality were determined. The results of the comparison showed that, overall, the procedures and methods that EPA and ESSAP use for sample collection are very similar. The number of minor differences noted were the result of restrictions or procedures necessary to ensure sample integrity and prevent the introduction of interfering compounds when samples are to be analyzed for chemical parameters. For most radio nuclide analyses, these additional procedures are not necessary. Another item noted was EPA's inclusion of steps that reduce the potential for sample cross-contamination by preparing (dressing) a location prior to collecting a sample or removing a portion of a sample prior to containerization

  11. Representative process sampling for reliable data analysis

    DEFF Research Database (Denmark)

    Julius, Lars Petersen; Esbensen, Kim

    2005-01-01

    (sampling variances) can be reduced greatly however, and sampling biases can be eliminated completely, by respecting a simple set of rules and guidelines provided by TOS. A systematic approach for description of process heterogeneity furnishes in-depth knowledge about the specific variability of any 1-D lot...

  12. Groundwater sampling in uranium reconnaissance

    International Nuclear Information System (INIS)

    Butz, T.R.

    1977-03-01

    The groundwater sampling program is based on the premise that ground water geochemistry reflects the chemical composition of, and geochemical processes active in the strata from which the sample is obtained. Pilot surveys have shown that wells are the best source of groundwater, although springs are sampled on occasion. The procedures followed in selecting a sampling site, the sampling itself, and the field measurements, as well as the site records made, are described

  13. Automated force volume image processing for biological samples.

    Directory of Open Access Journals (Sweden)

    Pavel Polyakov

    2011-04-01

    Full Text Available Atomic force microscopy (AFM has now become a powerful technique for investigating on a molecular level, surface forces, nanomechanical properties of deformable particles, biomolecular interactions, kinetics, and dynamic processes. This paper specifically focuses on the analysis of AFM force curves collected on biological systems, in particular, bacteria. The goal is to provide fully automated tools to achieve theoretical interpretation of force curves on the basis of adequate, available physical models. In this respect, we propose two algorithms, one for the processing of approach force curves and another for the quantitative analysis of retraction force curves. In the former, electrostatic interactions prior to contact between AFM probe and bacterium are accounted for and mechanical interactions operating after contact are described in terms of Hertz-Hooke formalism. Retraction force curves are analyzed on the basis of the Freely Jointed Chain model. For both algorithms, the quantitative reconstruction of force curves is based on the robust detection of critical points (jumps, changes of slope or changes of curvature which mark the transitions between the various relevant interactions taking place between the AFM tip and the studied sample during approach and retraction. Once the key regions of separation distance and indentation are detected, the physical parameters describing the relevant interactions operating in these regions are extracted making use of regression procedure for fitting experiments to theory. The flexibility, accuracy and strength of the algorithms are illustrated with the processing of two force-volume images, which collect a large set of approach and retraction curves measured on a single biological surface. For each force-volume image, several maps are generated, representing the spatial distribution of the searched physical parameters as estimated for each pixel of the force-volume image.

  14. A Tuning Procedure for ARX-based MPC of Multivariate Processes

    DEFF Research Database (Denmark)

    Olesen, Daniel; Huusom, Jakob Kjøbsted; Jørgensen, John Bagterp

    2013-01-01

    We present an optimization based tuning procedure with certain robustness properties for an offset free Model Predictive Controller (MPC). The MPC is designed for multivariate processes that can be represented by an ARX model. The stochastic model of the ARX model identified from input-output data...... is modified with an ARMA model designed as part of the MPC-design procedure to ensure offset-free control. The MPC is designed and implemented based on a state space model in innovation form. Expressions for the closed-loop dynamics of the unconstrained system is used to derive the sensitivity function...... to a constraint on the maximum of the sensitivity function. The latter constraint provides a robustness measure that is essential for the procedure. The method is demonstrated for two simulated examples: A Wood-Berry distillation column example and a cement mill example....

  15. 40 CFR 63.495 - Back-end process provisions-procedures to determine compliance using stripping technology.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Back-end process provisions-procedures to determine compliance using stripping technology. 63.495 Section 63.495 Protection of Environment...: Group I Polymers and Resins § 63.495 Back-end process provisions—procedures to determine compliance...

  16. Quality-assurance procedures: Method 5G determination of particulate emissions from wood heaters from a dilution tunnel sampling location

    Energy Technology Data Exchange (ETDEWEB)

    Ward, T.E.; Hartman, M.W.; Olin, R.C.; Rives, G.D.

    1989-06-01

    Quality-assurance procedures are contained in this comprehensive document intended to be used as an aid for wood-heater manufacturers and testing laboratories in performing particulate matter sampling of wood heaters according to EPA protocol, Method 5G. These procedures may be used in research and development, and as an aid in auditing and certification testing. A detailed, step-by-step quality assurance guide is provided to aid in the procurement and assembly of testing apparatus, to clearly describe the procedures, and to facilitate data collection and reporting. Suggested data sheets are supplied that can be used as an aid for both recordkeeping and certification applications. Throughout the document, activity matrices are provided to serve as a summary reference. Checklists are also supplied that can be used by testing personnel. Finally, for the purposes of ensuring data quality, procedures are outlined for apparatus operation, maintenance, and traceability. These procedures combined with the detailed description of the sampling and analysis protocol will help ensure the accuracy and reliability of Method 5G emission-testing results.

  17. Laboratory manual on sample preparation procedures for x-ray micro-analysis

    International Nuclear Information System (INIS)

    1997-01-01

    X-ray micro fluorescence is a non-destructive and sensitive method for studying the microscopic distribution of different elements in almost all kinds of samples. Since the beginning of this century, x-rays and electrons have been used for the analysis of many different kinds of material. Techniques which rely on electrons are mainly developed for microscopic studies, and are used in conventional Electron Microscopy (EM) or Scanning Electron Microscopy (SEM), while x-rays are widely used for chemical analysis at the microscopic level. The first chemical analysis by fluorescence spectroscopy using small x-ray beams was conducted in 1928 by Glockner and Schreiber. Since then much work has been devoted to developing different types of optical systems for focusing an x-ray beam, but the efficiency of these systems is still inferior to the conventional electron optical systems. However, even with a poor optical efficiency, the x-ray microbeam has many advantages compared with electron or proton induced x-ray emission methods. These include: The analyses are non-destructive, losses of mass are negligible, and due to the low thermal loading of x-rays, materials which may be thermally degraded can be analysed; Samples can be analysed in air, and no vacuum is required, therefore specimens with volatile components such as water in biological samples, can be imaged at normal pressure and temperature; No charging occurs during analysis and therefore coating of the sample with a conductive layer is not necessary; With these advantages, simpler sample preparation procedures including mounting and preservation can be used

  18. PGDP [Paducah Gaseous Diffusion Plant]-UF6 handling, sampling, analysis and associated QC/QA and safety related procedures

    International Nuclear Information System (INIS)

    Harris, R.L.

    1987-01-01

    This document is a compilation of Paducah Gaseous Diffusion Plant procedures on UF 6 handling, sampling, and analysis, along with associated QC/QA and safety related procedures. It was assembled for transmission by the US Department of Energy to the Korean Advanced Energy Institute as a part of the US-Korea technical exchange program

  19. Management and governance processes in community health coalitions: a procedural justice perspective.

    Science.gov (United States)

    Weiner, Bryan J; Alexander, Jeffrey A; Shortell, Stephen M

    2002-12-01

    Community-based coalitions are a popular strategy for promoting community health despite the fact that coalitions often fail to achieve measurable results. Using a procedural justice framework, this study seeks to advance knowledge about the relationship between coalition governance and management processes and indicators of coalition functioning. Member survey data from 25 coalitions participating in the Community Care Network Demonstration Program were analyzed using two-stage least squares regression. Results show that personal influence in decision making. decision process clarity, and collaborative conflict resolution were significantly associated with procedural fairness perceptions. Procedural fairness perceptions, in turn, were positively associated with member satisfaction with coalition decisions, but not personal engagement in the coalition or organizational integration of coalition goals and activities. Personal influence in decision making and collaborative conflict resolution also exhibited direct relationships with all three indicators of coalition functioning examined in the study.

  20. Metabolic fingerprinting of high-fat plasma samples processed by centrifugation- and filtration-based protein precipitation delineates significant differences in metabolite information coverage.

    Science.gov (United States)

    Barri, Thaer; Holmer-Jensen, Jens; Hermansen, Kjeld; Dragsted, Lars O

    2012-03-09

    Metabolomics and metabolic fingerprinting are being extensively employed for improved understanding of biological changes induced by endogenous or exogenous factors. Blood serum or plasma samples are often employed for metabolomics studies. Plasma protein precipitation (PPP) is currently performed in most laboratories before LC-MS analysis. However, the impact of fat content in plasma samples on metabolite coverage has not previously been investigated. Here, we have studied whether PPP procedures influence coverage of plasma metabolites from high-fat plasma samples. An optimized UPLC-QTOF/MS metabolic fingerprinting approach and multivariate modeling (PCA and OPLS-DA) were utilized for finding characteristic metabolite changes induced by two PPP procedures; centrifugation and filtration. We used 12-h fasting samples and postprandial samples collected at 2h after a standardized high-fat protein-rich meal in obese non-diabetic subjects recruited in a dietary intervention. The two PPP procedures as well as external and internal standards (ISs) were used to track errors in response normalization and quantification. Remarkably and sometimes uniquely, the fPPP, but not the cPPP approach, recovered not only high molecular weight (HMW) lipophilic metabolites, but also small molecular weight (SMW) relatively polar metabolites. Characteristic SMW markers of postprandial samples were aromatic and branched-chain amino acids that were elevated (p<0.001) as a consequence of the protein challenge. In contrast, some HMW lipophilic species, e.g. acylcarnitines, were moderately lower (p<0.001) in postprandial samples. LysoPCs were largely unaffected. In conclusion, the fPPP procedure is recommended for processing high-fat plasma samples in metabolomics studies. While method improvements presented here were clear, use of several ISs revealed substantial challenges to untargeted metabolomics due to large and variable matrix effects. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Application of CWC analytical procedures for safeguards; Analysis of phosphorus-containing organic chemical signatures from environmental samples; Final report on task FIN A844 on the Finnish support programme to IAEA safeguards

    Energy Technology Data Exchange (ETDEWEB)

    Rautio, M; Bjoerk, H; Haekkinen, V; Kostiainen, O; Kuitunen, M L; Lehtonen, P; Mesilaakso, M; Soederstroem, M [Finnish Inst. for Verification of the Chemical Weapons Convention, Helsinki (Finland)

    1995-03-01

    Solvent extraction can be used for the recovery of U and Pu from irradiated fuel. The most potential organic chemical signatures are extractants and solvents used in reprocessing plants. The PUREX process is widely used in reprocessing. It uses tri-n-butyl phosphate (TBP) as extractant in an organic solvent for U and Pu from irradiated fuel and U from its ores. TBP is a strong extractant for tetra and hexavalent actinides from nitric acid media. Stable complexes are formed between actinide nitrate and TBP which are soluble in the organic phase. Sample containing TBP and some radiolysis products can indicate that TBP is used for reprocessing nuclear fuel. The TBP will decompose in the PUREX process to mono-and dibutyl phosphates (MBP and DBP). TBP, DBP and MBP have been analysed from air, water, soil, and sediment samples according to slightly modified procedures presented in Recommended Operating Procedures for Sampling and Analysis in the Verification of Chemical Disarmament. The limits of detection for the phosphates have been determined for air, water and soil samples. (orig.) (12 refs., 8 figs., 4 tabs.).

  2. A task based design procedure and modelling approached for industrial crystallization processes

    NARCIS (Netherlands)

    Menon, A.R.

    2006-01-01

    A synthesis-based approach to the design of crystallizers and industrial crystallization processes is introduced in this thesis. An ontology for a task-based design procedure has been developed which breaks the crystallization process into a subset of basic functions (physical tasks) which transform

  3. Multipurpose ANSYS FE procedure for welding processes simulation

    Energy Technology Data Exchange (ETDEWEB)

    Capriccioli, Andrea [ENEA CR Frascati, Via Enrico Fermi 45, 00044 Frascati (Italy); Frosi, Paolo [ENEA CR Frascati, Via Enrico Fermi 45, 00044 Frascati (Italy)], E-mail: frosi@frascati.enea.it

    2009-06-15

    ANSYS FE procedures and 3D models for thermal and mechanical simulation of both Laser and TIG welding processes are presented. The special features are the applicability to a non uniform gap and the use of a fast iterative procedure that assures the constancy of the fixed maximum temperature along the single pass and between each pass and the following, apart from their shapes and sizes. All the thermal and mechanical material properties of both INCONEL 625 and AISI 316 are described till to liquid phase; convection and radiation effects are considered. The 3D ANSYS models use both brick and non linear contact elements and elastic and elastic-plastic materials. Two full simulation are presented: a laser welding test (taken from ENEA) and a TIG welding one (source W7-X) with the root seam plus 14 passes; thermal and mechanical results are reported in the two cases and for the latter an extensive sensitivity analysis, changing mesh size of the filling material, welding speed and material properties, is explained with results and comparisons. This large sensitivity analysis has been executed for TIG welding because in this case (multi-pass welding) the reduction of CPU time is a strong requirement; but some conclusions are helpful for laser welding too. The mechanical calculation results very sensitive to the mesh shape: this fact implies very fine and regular meshes. The specimens are first restrained and then welded with the foreseen welding procedure; after that it is released and the final linear and angular shrinkages are calculated. The ANSYS birth and death procedure is used and the CPU time was strongly reduced.

  4. Multipurpose ANSYS FE procedure for welding processes simulation

    International Nuclear Information System (INIS)

    Capriccioli, Andrea; Frosi, Paolo

    2009-01-01

    ANSYS FE procedures and 3D models for thermal and mechanical simulation of both Laser and TIG welding processes are presented. The special features are the applicability to a non uniform gap and the use of a fast iterative procedure that assures the constancy of the fixed maximum temperature along the single pass and between each pass and the following, apart from their shapes and sizes. All the thermal and mechanical material properties of both INCONEL 625 and AISI 316 are described till to liquid phase; convection and radiation effects are considered. The 3D ANSYS models use both brick and non linear contact elements and elastic and elastic-plastic materials. Two full simulation are presented: a laser welding test (taken from ENEA) and a TIG welding one (source W7-X) with the root seam plus 14 passes; thermal and mechanical results are reported in the two cases and for the latter an extensive sensitivity analysis, changing mesh size of the filling material, welding speed and material properties, is explained with results and comparisons. This large sensitivity analysis has been executed for TIG welding because in this case (multi-pass welding) the reduction of CPU time is a strong requirement; but some conclusions are helpful for laser welding too. The mechanical calculation results very sensitive to the mesh shape: this fact implies very fine and regular meshes. The specimens are first restrained and then welded with the foreseen welding procedure; after that it is released and the final linear and angular shrinkages are calculated. The ANSYS birth and death procedure is used and the CPU time was strongly reduced.

  5. Uranium tailings sampling manual

    International Nuclear Information System (INIS)

    Feenstra, S.; Reades, D.W.; Cherry, J.A.; Chambers, D.B.; Case, G.G.; Ibbotson, B.G.

    1985-01-01

    The purpose of this manual is to describe the requisite sampling procedures for the application of uniform high-quality standards to detailed geotechnical, hydrogeological, geochemical and air quality measurements at Canadian uranium tailings disposal sites. The selection and implementation of applicable sampling procedures for such measurements at uranium tailings disposal sites are complicated by two primary factors. Firstly, the physical and chemical nature of uranium mine tailings and effluent is considerably different from natural soil materials and natural waters. Consequently, many conventional methods for the collection and analysis of natural soils and waters are not directly applicable to tailings. Secondly, there is a wide range in the physical and chemical nature of uranium tailings. The composition of the ore, the milling process, the nature of tailings depositon, and effluent treatment vary considerably and are highly site-specific. Therefore, the definition and implementation of sampling programs for uranium tailings disposal sites require considerable evaluation, and often innovation, to ensure that appropriate sampling and analysis methods are used which provide the flexibility to take into account site-specific considerations. The following chapters describe the objective and scope of a sampling program, preliminary data collection, and the procedures for sampling of tailings solids, surface water and seepage, tailings pore-water, and wind-blown dust and radon

  6. Implementation of an Enhanced Measurement Control Program for handling nuclear safety samples at WSRC

    International Nuclear Information System (INIS)

    Boler-Melton, C.; Holland, M.K.

    1991-01-01

    In the separation and purification of nuclear material, nuclear criticality safety (NCS) is of primary concern. The primary nuclear criticality safety controls utilized by the Savannah River Site (SRS) Separations Facilities involve administrative and process equipment controls. Additional assurance of NCS is obtained by identifying key process hold points where sampling is used to independently verify the effectiveness of production control. Nuclear safety measurements of samples from these key process locations provide a high degree of assurance that processing conditions are within administrative and procedural nuclear safety controls. An enhanced procedure management system aimed at making improvements in the quality, safety, and conduct of operation was implemented for Nuclear Safety Sample (NSS) receipt, analysis, and reporting. All procedures with nuclear safety implications were reviewed for accuracy and adequate detail to perform the analytical measurements safely, efficiently, and with the utmost quality. Laboratory personnel worked in a ''Deliberate Operating'' mode (a systematic process requiring continuous expert oversight during all phases of training, testing, and implementation) to initiate the upgrades. Thus, the effort to revise and review nuclear safety sample procedures involved a team comprised of a supervisor, chemist, and two technicians for each procedure. Each NSS procedure was upgraded to a ''Use Every Time'' (UET) procedure with sign-off steps to ensure compliance with each step for every nuclear safety sample analyzed. The upgrade program met and exceeded both the long and short term customer needs by improving measurement reliability, providing objective evidence of rigid adherence to program principles and requirements, and enhancing the system for independent verification of representative sampling from designated NCS points

  7. Experiences with preventive procedures application in the process of beer production in Czech Republic

    Directory of Open Access Journals (Sweden)

    Jana Kotovicová

    2011-01-01

    Full Text Available Food-processing industry is an intriguing field regarding prevention procedures application. All food-processing operations have common fundamental spheres of problems – wastewater polluted by organic substances, solid waste of biological origin and losses during source material processing. Beer production process is a representative of food-processing sphere. The brewing industry has an ancient tradition and is still a dynamic sector open to new developments in technology and scientific progress. A case study of beer production in Czech Republic has been performed. During the work on the project, there were utilized methodical procedures of Cleaner Production, best available technologies (BAT utilization and hazard analysis critical control points (HACCP, optimization of final technology operation.

  8. 76 FR 54528 - Standard Operating Procedures (SOP) of the Aircraft Certification Service (AIR) Process for the...

    Science.gov (United States)

    2011-09-01

    ...) of the Aircraft Certification Service (AIR) Process for the Sequencing of Certification and... on the Aircraft Certification Service (AIR) standard operating procedure (SOP) describing the process... comments on the SOP : AIR-100-001; Standard Operating Procedure--Aircraft Certification Service Project...

  9. 1979-80 Budget Process. Phase I: Educational Programs. Procedures Manual.

    Science.gov (United States)

    Los Angeles Community Coll. District, CA. Div. of Educational Planning and Development.

    As Proposition 13 necessitated more drastic curtailment of expenditures than had been anticipated when the modified zero-based operational plan for 1978-79 was devised, the budget development procedure was revised for 1979-80. The process is divided into three phases: educational programs, district fiscal plan, and the operational plan. This…

  10. Green approaches in sample preparation of bioanalytical samples prior to chromatographic analysis.

    Science.gov (United States)

    Filippou, Olga; Bitas, Dimitrios; Samanidou, Victoria

    2017-02-01

    Sample preparation is considered to be the most challenging step of the analytical procedure, since it has an effect on the whole analytical methodology, therefore it contributes significantly to the greenness or lack of it of the entire process. The elimination of the sample treatment steps, pursuing at the same time the reduction of the amount of the sample, strong reductions in consumption of hazardous reagents and energy also maximizing safety for operators and environment, the avoidance of the use of big amount of organic solvents, form the basis for greening sample preparation and analytical methods. In the last decade, the development and utilization of greener and sustainable microextraction techniques is an alternative to classical sample preparation procedures. In this review, the main green microextraction techniques (solid phase microextraction, stir bar sorptive extraction, hollow-fiber liquid phase microextraction, dispersive liquid - liquid microextraction, etc.) will be presented, with special attention to bioanalytical applications of these environment-friendly sample preparation techniques which comply with the green analytical chemistry principles. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Heavy water standards. Qualitative analyses, sample treating, stocking and manipulation

    International Nuclear Information System (INIS)

    Pavelescu, M.; Steflea, D.; Mihancea, I.; Varlam, M.; Irimescu, R.

    1995-01-01

    This paper presents methods and procedures for measuring heavy water concentration, and also sampling, stocking and handling of samples to be analysed. The main concentration analysis methods are: mass spectrometry, for concentrations less then 1%, densitometry, for concentrations within the range 1% - 99% and infrared spectrometry for concentrations above 99%. Procedures of sampling, processing and purification appropriate to these measuring methods were established. 1 Tab

  12. Recommended procedures for performance testing of radiobioassay laboratories: Volume 2, In vitro samples

    International Nuclear Information System (INIS)

    Fenrick, H.W.; MacLellan, J.A.

    1988-11-01

    Draft American National Standards Institute (ANSI) Standard N13.30 (Performance Criteria for Radiobioassay) was developed for the US Department of Energy and the US Nuclear Regulatory Commission to help ensure that bioassay laboratories provide accurate and consistent results. The draft standard specifies the criteria for defining the procedures necessary to establish a bioassay performance-testing laboratory and program. The bioassay testing laboratory will conduct tests to evaluate the performance of service laboratories. Pacific Northwest Laboratory helped develop testing procedures as part of an effort to evaluate the performance criteria by testing the existing measurement capabilities of various bioassay laboratories. This report recommends guidelines for the preparation, handling, storage, distribution, shipping, and documentation of in vitro test samples (artificial urine and fecal matter) for indirect bioassay. The data base and recommended records system for documenting radiobioassay performance at the service laboratories are also presented. 8 refs., 3 tabs

  13. Spiral model of procedural cycle of educational process management

    Directory of Open Access Journals (Sweden)

    Bezrukov Valery I.

    2016-01-01

    Full Text Available The article analyzes the nature and characteristics of the spiral model Procedure educational systems management cycle. The authors identify patterns between the development of information and communication technologies and the transformation of the education management process, give the characteristics of the concept of “information literacy” and “Media Education”. Consider the design function, determine its potential in changing the traditional educational paradigm to the new - information.

  14. Sample Handling and Processing on Mars for Future Astrobiology Missions

    Science.gov (United States)

    Beegle, Luther; Kirby, James P.; Fisher, Anita; Hodyss, Robert; Saltzman, Alison; Soto, Juancarlos; Lasnik, James; Roark, Shane

    2011-01-01

    In most analytical investigations, there is a need to process complex field samples for the unique detection of analytes especially when detecting low concentration organic molecules that may identify extraterrestrial life. Sample processing for analytical instruments is time, resource and manpower consuming in terrestrial laboratories. Every step in this laborious process will have to be automated for in situ life detection. We have developed, and are currently demonstrating, an automated wet chemistry preparation system that can operate autonomously on Earth and is designed to operate under Martian ambient conditions. This will enable a complete wet chemistry laboratory as part of future missions. Our system, namely the Automated Sample Processing System (ASPS) receives fines, extracts organics through solvent extraction, processes the extract by removing non-organic soluble species and delivers sample to multiple instruments for analysis (including for non-organic soluble species).

  15. Selection of blood sampling times for determination of 51Cr-EDTA clearance in a screeening procedure

    International Nuclear Information System (INIS)

    Gullquist, R.; Askergren, A.; Brandt, R.; Silk, B.; Strandell, T.; Huddinge University Hospital

    1983-01-01

    In a group of 44 construction workers various blood sampling protocols were compared with regard to variability of the 51 Cr-EDTA clearance on repeated determinations. A comparison was also made among the different blood sampling protocols with a reference method using Simpson's formula in the area calculation. A double slope method lasting for two and a half hours was finally choosen and suggested as a screening procedure in industrial environment with blood sampling at 5, 15, 90, 120, 135 and 150 minutes after injection and with the patient resting in a semirecumbent position. (orig.) [de

  16. Differentiation of ileostomy from colostomy procedures: assessing the accuracy of current procedural terminology codes and the utility of natural language processing.

    Science.gov (United States)

    Vo, Elaine; Davila, Jessica A; Hou, Jason; Hodge, Krystle; Li, Linda T; Suliburk, James W; Kao, Lillian S; Berger, David H; Liang, Mike K

    2013-08-01

    Large databases provide a wealth of information for researchers, but identifying patient cohorts often relies on the use of current procedural terminology (CPT) codes. In particular, studies of stoma surgery have been limited by the accuracy of CPT codes in identifying and differentiating ileostomy procedures from colostomy procedures. It is important to make this distinction because the prevalence of complications associated with stoma formation and reversal differ dramatically between types of stoma. Natural language processing (NLP) is a process that allows text-based searching. The Automated Retrieval Console is an NLP-based software that allows investigators to design and perform NLP-assisted document classification. In this study, we evaluated the role of CPT codes and NLP in differentiating ileostomy from colostomy procedures. Using CPT codes, we conducted a retrospective study that identified all patients undergoing a stoma-related procedure at a single institution between January 2005 and December 2011. All operative reports during this time were reviewed manually to abstract the following variables: formation or reversal and ileostomy or colostomy. Sensitivity and specificity for validation of the CPT codes against the mastery surgery schedule were calculated. Operative reports were evaluated by use of NLP to differentiate ileostomy- from colostomy-related procedures. Sensitivity and specificity for identifying patients with ileostomy or colostomy procedures were calculated for CPT codes and NLP for the entire cohort. CPT codes performed well in identifying stoma procedures (sensitivity 87.4%, specificity 97.5%). A total of 664 stoma procedures were identified by CPT codes between 2005 and 2011. The CPT codes were adequate in identifying stoma formation (sensitivity 97.7%, specificity 72.4%) and stoma reversal (sensitivity 74.1%, specificity 98.7%), but they were inadequate in identifying ileostomy (sensitivity 35.0%, specificity 88.1%) and colostomy (75

  17. Towards Standardization of Sampling Methodology for Evaluation of ...

    African Journals Online (AJOL)

    This article proposes the procedure that may be adopted for comparable, representative and cost effective, soil sampling, and thereafter explores the policy issues regarding standardization of sampling activities and analytical process as it relates to soil pollution in Nigeria. Standardized sampling and analytical data for soil ...

  18. Scenes for Social Information Processing in Adolescence: Item and factor analytic procedures for psychometric appraisal.

    Science.gov (United States)

    Vagos, Paula; Rijo, Daniel; Santos, Isabel M

    2016-04-01

    Relatively little is known about measures used to investigate the validity and applications of social information processing theory. The Scenes for Social Information Processing in Adolescence includes items built using a participatory approach to evaluate the attribution of intent, emotion intensity, response evaluation, and response decision steps of social information processing. We evaluated a sample of 802 Portuguese adolescents (61.5% female; mean age = 16.44 years old) using this instrument. Item analysis and exploratory and confirmatory factor analytic procedures were used for psychometric examination. Two measures for attribution of intent were produced, including hostile and neutral; along with 3 emotion measures, focused on negative emotional states; 8 response evaluation measures; and 4 response decision measures, including prosocial and impaired social behavior. All of these measures achieved good internal consistency values and fit indicators. Boys seemed to favor and choose overt and relational aggression behaviors more often; girls conveyed higher levels of neutral attribution, sadness, and assertiveness and passiveness. The Scenes for Social Information Processing in Adolescence achieved adequate psychometric results and seems a valuable alternative for evaluating social information processing, even if it is essential to continue investigation into its internal and external validity. (c) 2016 APA, all rights reserved.

  19. Nonradioactive Dangerous Waste Landfill sampling and analysis plan and data quality objectives process summary report

    International Nuclear Information System (INIS)

    Smith, R.C.

    1997-08-01

    This sampling and analysis plan defines the sampling and analytical activities and associated procedures that will be used to support the Nonradioactive Dangerous Waste Landfill soil-gas investigation. This SAP consists of three sections: this introduction, the field sampling plan, and the quality assurance project plan. The field sampling plan defines the sampling and analytical methodologies to be performed

  20. Collection and processing of plant, animal and soil samples from Bikini, Enewetak and Rongelap Atolls

    Energy Technology Data Exchange (ETDEWEB)

    Stuart, M.L.

    1995-09-01

    The United States used the Marshall Islands for its nuclear weapons program testing site from 1946 to 1958. The BRAVO test was detonated at Bikini Atoll on March 1, 1954. Due to shifting wind conditions at the time of the nuclear detonation, many of the surrounding Atolls became contaminated with fallout (radionuclides carried by the wind currents). Lawrence Livermore National Laboratory`s (LLNL) Marshall Islands Project has been responsible for the collecting, processing, and analyzing of food crops, vegetation, soil, water, animals, and marine species to characterize the radionuclides in the environment, and to estimate dose at atolls that may have been contaminated. Tropical agriculture experiments reducing the uptake of {sup 137}Cs have been conducted on Bikini Atoll. The Marshall Islands field team and laboratory processing team play an important role in the overall scheme of the Marshall Islands Dose Assessment and Radioecology Project. This report gives a general description of the Marshall Islands field sampling and laboratory processing procedures currently used by our staff.

  1. Collection and processing of plant, animal and soil samples from Bikini, Enewetak and Rongelap Atolls

    International Nuclear Information System (INIS)

    Stuart, M.L.

    1995-09-01

    The United States used the Marshall Islands for its nuclear weapons program testing site from 1946 to 1958. The BRAVO test was detonated at Bikini Atoll on March 1, 1954. Due to shifting wind conditions at the time of the nuclear detonation, many of the surrounding Atolls became contaminated with fallout (radionuclides carried by the wind currents). Lawrence Livermore National Laboratory's (LLNL) Marshall Islands Project has been responsible for the collecting, processing, and analyzing of food crops, vegetation, soil, water, animals, and marine species to characterize the radionuclides in the environment, and to estimate dose at atolls that may have been contaminated. Tropical agriculture experiments reducing the uptake of 137 Cs have been conducted on Bikini Atoll. The Marshall Islands field team and laboratory processing team play an important role in the overall scheme of the Marshall Islands Dose Assessment and Radioecology Project. This report gives a general description of the Marshall Islands field sampling and laboratory processing procedures currently used by our staff

  2. A pre-concentration procedure using coprecipitation for determination of lead and iron in several samples using flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Saracoglu, S.; Soylak, M.; Peker, D.S. Kacar; Elci, L.; Santos, W.N.L. dos; Lemos, V.A.; Ferreira, S.L.C.

    2006-01-01

    The present paper proposes a pre-concentration procedure for determination of lead and iron in several samples by flame atomic absorption spectrometry. In it, lead(II) and iron(III) ions are coprecipitated using the violuric acid-copper(II) system as collector. Afterwards, the precipitate is dissolved with 1 M HNO 3 solution and the metal ions are determined. The optimization step was performed using factorial design involving the variables: pH, violuric acid mass (VA) and copper concentration (Cu). Using the optimized experimental conditions, the proposed procedure allows the determination these metals with detection limits of 0.18 μg L -1 for iron and 0.16 μg L -1 for lead. The effects of foreign ions on the pre-concentration procedure were also evaluated and the results demonstrated that this method could be applied for determination of iron and lead in several real samples. The proposed method was successfully applied to the analysis of seawater, urine, mineral water, soil and physiological solution samples. The concentrations of lead and iron achieved in these samples agree well with others data reported in the literature

  3. Sample handling and chemical procedures for efficacious trace analysis of urine by neutron activation analysis

    International Nuclear Information System (INIS)

    Blotcky, A.J.; Rack, E.P.; Roman, F.R.

    1988-01-01

    Important for the determination of trace elements, ions, or compounds in urine by chemical neutron activation analysis is the optimization of sample handling, preirradiation chemistry, and radioassay procedures necessary for viable analysis. Each element, because of its natural abundance in the earth's crust and, hence, its potential for reagent and environmental contamination, requires specific procedures for storage, handling, and preirradiation chemistry. Radioassay techniques for radionuclides vary depending on their half-lives and decay characteristics. Described in this paper are optimized procedures for aluminum and selenium. While 28 Al (T 1/2 = 2.24 min) and 77m Se(T 1/2 = 17.4s) have short half-lives, their gamma-ray spectra are quite different. Aluminum-28 decays by a 1779-keV gamma and 77m Se by a 162-keV gamma. Unlike selenium, aluminum is a ubiquitous element in the environment requiring special handling to minimize contamination in all phases of its analytical determination

  4. Remote sampling and analysis of highly radioactive samples in shielded boxes

    International Nuclear Information System (INIS)

    Kirpikov, D.A.; Miroshnichenko, I.V.; Pykhteev, O.Yu.

    2010-01-01

    equipped with radiation resistant video cameras provided for additional visual inspection. All the acquired information including visual images is sent to the workstation of an operator who controls handling of highly radioactive samples. Authorized participants of chemical control are able to supervise the sampling procedure and process the obtained results via local area network owing to inclusion of the workstation in the common data acquisition, processing and storage system. The paper describes the developed equipment and solutions and discusses the issues related to development of the local computer-aided chemical control system. (author)

  5. On-line sample processing methods in flow analysis

    DEFF Research Database (Denmark)

    Miró, Manuel; Hansen, Elo Harald

    2008-01-01

    In this chapter, the state of the art of flow injection and related approaches thereof for automation and miniaturization of sample processing regardless of the aggregate state of the sample medium is overviewed. The potential of the various generation of flow injection for implementation of in...

  6. Aviation Safety Reporting System: Process and Procedures

    Science.gov (United States)

    Connell, Linda J.

    1997-01-01

    The Aviation Safety Reporting System (ASRS) was established in 1976 under an agreement between the Federal Aviation Administration (FAA) and the National Aeronautics and Space Administration (NASA). This cooperative safety program invites pilots, air traffic controllers, flight attendants, maintenance personnel, and others to voluntarily report to NASA any aviation incident or safety hazard. The FAA provides most of the program funding. NASA administers the program, sets its policies in consultation with the FAA and aviation community, and receives the reports submitted to the program. The FAA offers those who use the ASRS program two important reporting guarantees: confidentiality and limited immunity. Reports sent to ASRS are held in strict confidence. More than 350,000 reports have been submitted since the program's beginning without a single reporter's identity being revealed. ASRS removes all personal names and other potentially identifying information before entering reports into its database. This system is a very successful, proof-of-concept for gathering safety data in order to provide timely information about safety issues. The ASRS information is crucial to aviation safety efforts both nationally and internationally. It can be utilized as the first step in safety by providing the direction and content to informed policies, procedures, and research, especially human factors. The ASRS process and procedures will be presented as one model of safety reporting feedback systems.

  7. Analysis of Memory Formation during General Anesthesia (Propofol/Remifentanil) for Elective Surgery Using the Process-dissociation Procedure.

    Science.gov (United States)

    Hadzidiakos, Daniel; Horn, Nadja; Degener, Roland; Buchner, Axel; Rehberg, Benno

    2009-08-01

    There have been reports of memory formation during general anesthesia. The process-dissociation procedure has been used to determine if these are controlled (explicit/conscious) or automatic (implicit/unconscious) memories. This study used the process-dissociation procedure with the original measurement model and one which corrected for guessing to determine if more accurate results were obtained in this setting. A total of 160 patients scheduled for elective surgery were enrolled. Memory for words presented during propofol and remifentanil general anesthesia was tested postoperatively by using a word-stem completion task in a process-dissociation procedure. To assign possible memory effects to different levels of anesthetic depth, the authors measured depth of anesthesia using the BIS XP monitor (Aspect Medical Systems, Norwood, MA). Word-stem completion performance showed no evidence of memory for intraoperatively presented words. Nevertheless, an evaluation of these data using the original measurement model for process-dissociation data suggested an evidence of controlled (C = 0.05; 95% confidence interval [CI] 0.02-0.08) and automatic (A = 0.11; 95% CI 0.09-0.12) memory processes (P memory processes was obtained. The authors report and discuss parallel findings for published data sets that were generated by using the process-dissociation procedure. Patients had no memories for auditory information presented during propofol/remifentanil anesthesia after midazolam premedication. The use of the process-dissociation procedure with the original measurement model erroneously detected memories, whereas the extended model, corrected for guessing, correctly revealed no memory.

  8. The Analytical Pragmatic Structure of Procedural Due Process: A Framework for Inquiry in Administrative Decision Making.

    Science.gov (United States)

    Fisher, James E.; Sealey, Ronald W.

    The study describes the analytical pragmatic structure of concepts and applies this structure to the legal concept of procedural due process. This structure consists of form, purpose, content, and function. The study conclusions indicate that the structure of the concept of procedural due process, or any legal concept, is not the same as the…

  9. 9 CFR 381.305 - Equipment and procedures for heat processing systems.

    Science.gov (United States)

    2010-01-01

    ... AND VOLUNTARY INSPECTION AND CERTIFICATION POULTRY PRODUCTS INSPECTION REGULATIONS Canning and Canned... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Equipment and procedures for heat processing systems. 381.305 Section 381.305 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE...

  10. The development of neutron activation, sample transportation and γ-ray counting routine system for numbers of geological samples

    International Nuclear Information System (INIS)

    Shibata Shin-nosuke; Tanaka, Tsuyoshi; Minami, Masayo

    2001-01-01

    A new gamma-ray counting and data processing system for non-destructive neutron activation analysis has been set up in Radioisotope Center in Nagoya University. The system carry out gamma-ray counting, sample change and data processing automatically, and is able to keep us away from parts of complicated operations in INAA. In this study, we have arranged simple analytical procedure that makes practical works easier than previous. The concrete flow is described from the reparation of powder rock samples to gamma-ray counting and data processing by the new INAA system. Then it is run over that the analyses used two Geological Survey of Japan rock reference samples JB-1a and JG-1a in order to evaluate how the new analytical procedure give any speediness and accuracy for analyses of geological materials. Two United States Geological Survey reference samples BCR-1 and G-2 used as the standard respectively. Twenty two elements for JB-1a and 25 elements for JG-1a were analyzed, the uncertainty are <5% for Na, Sc, Fe, Co, La, Ce, Sm, Eu, Yb, Lu, Hf, Ta and Th, and of <10% for Cr, Zn, Cs, Ba, Nd, Tb and U. This system will enable us to analyze more than 1500 geologic samples per year. (author)

  11. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE AND SHIPMENT OF URINE SAMPLES FOR SELECTED METALS AND PESTICIDES (UA-F-20.1)

    Science.gov (United States)

    The purpose of this SOP is to guide the collection, storage, and shipment of urine samples collected for the NHEXAS Arizona project. This SOP provides a brief description of sample, collection, preservation, storage, shipping, and custody procedures. This procedure was followed ...

  12. A statistical rationale for establishing process quality control limits using fixed sample size, for critical current verification of SSC superconducting wire

    International Nuclear Information System (INIS)

    Pollock, D.A.; Brown, G.; Capone, D.W. II; Christopherson, D.; Seuntjens, J.M.; Woltz, J.

    1992-01-01

    This work has demonstrated the statistical concepts behind the XBAR R method for determining sample limits to verify billet I c performance and process uniformity. Using a preliminary population estimate for μ and σ from a stable production lot of only 5 billets, we have shown that reasonable sensitivity to systematic process drift and random within billet variation may be achieved, by using per billet subgroup sizes of moderate proportions. The effects of subgroup size (n) and sampling risk (α and β) on the calculated control limits have been shown to be important factors that need to be carefully considered when selecting an actual number of measurements to be used per billet, for each supplier process. Given the present method of testing in which individual wire samples are ramped to I c only once, with measurement uncertainty due to repeatability and reproducibility (typically > 1.4%), large subgroups (i.e. >30 per billet) appear to be unnecessary, except as an inspection tool to confirm wire process history for each spool. The introduction of the XBAR R method or a similar Statistical Quality Control procedure is recommend for use in the superconducing wire production program, particularly when the program transitions from requiring tests for all pieces of wire to sampling each production unit

  13. Automated radioanalytical system incorporating microwave-assisted sample preparation, chemical separation, and online radiometric detection for the monitoring of total 99Tc in nuclear waste processing streams.

    Science.gov (United States)

    Egorov, Oleg B; O'Hara, Matthew J; Grate, Jay W

    2012-04-03

    An automated fluidic instrument is described that rapidly determines the total (99)Tc content of aged nuclear waste samples, where the matrix is chemically and radiologically complex and the existing speciation of the (99)Tc is variable. The monitor links microwave-assisted sample preparation with an automated anion exchange column separation and detection using a flow-through solid scintillator detector. The sample preparation steps acidify the sample, decompose organics, and convert all Tc species to the pertechnetate anion. The column-based anion exchange procedure separates the pertechnetate from the complex sample matrix, so that radiometric detection can provide accurate measurement of (99)Tc. We developed a preprogrammed spike addition procedure to automatically determine matrix-matched calibration. The overall measurement efficiency that is determined simultaneously provides a self-diagnostic parameter for the radiochemical separation and overall instrument function. Continuous, automated operation was demonstrated over the course of 54 h, which resulted in the analysis of 215 samples plus 54 hly spike-addition samples, with consistent overall measurement efficiency for the operation of the monitor. A sample can be processed and measured automatically in just 12.5 min with a detection limit of 23.5 Bq/mL of (99)Tc in low activity waste (0.495 mL sample volume), with better than 10% RSD precision at concentrations above the quantification limit. This rapid automated analysis method was developed to support nuclear waste processing operations planned for the Hanford nuclear site.

  14. Challenging genosensors in food samples: The case of gluten determination in highly processed samples.

    Science.gov (United States)

    Martín-Fernández, Begoña; de-los-Santos-Álvarez, Noemí; Martín-Clemente, Juan Pedro; Lobo-Castañón, María Jesús; López-Ruiz, Beatriz

    2016-01-01

    Electrochemical genosensors have undergone an enormous development in the last decades, but only very few have achieved a quantification of target content in highly processed food samples. The detection of allergens, and particularly gluten, is challenging because legislation establishes a threshold of 20 ppm for labeling as gluten-free but most genosensors expresses the results in DNA concentration or DNA copies. This paper describes the first attempt to correlate the genosensor response and the wheat content in real samples, even in the case of highly processed food samples. A sandwich-based format, comprising a capture probe immobilized onto the screen-printed gold electrode, and a signaling probe functionalized with fluorescein isothiocyanate (FITC), both hybridizing with the target was used. The hybridization event was electrochemically monitored by adding an anti-FITC peroxidase (antiFITC-HRP) and its substrate, tetramethylbenzidine. Binary model mixtures, as a reference material, and real samples have been analyzed. DNA from food was extracted and a fragment encoding the immunodominant peptide of α2-gliadin amplified by a tailored PCR. The sensor was able to selectively detect toxic cereals for celiac patients, such as different varieties of wheat, barley, rye and oats, from non-toxic plants. As low as 0.001% (10 mg/kg) of wheat flour in an inert matrix was reliably detected, which directly compete with the current method of choice for DNA detection, the real-time PCR. A good correlation with the official immunoassay was found in highly processed food samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Measuring fuel moisture content in Alaska: standard methods and procedures.

    Science.gov (United States)

    Rodney A. Norum; Melanie. Miller

    1984-01-01

    Methods and procedures are given for collecting and processing living and dead plant materials for the purpose of determining their water content. Wild-land fuels in Alaska are emphasized, but the methodology is applicable elsewhere. Guides are given for determining the number of samples needed to attain a chosen precision. Detailed procedures are presented for...

  16. On a Robust MaxEnt Process Regression Model with Sample-Selection

    Directory of Open Access Journals (Sweden)

    Hea-Jung Kim

    2018-04-01

    Full Text Available In a regression analysis, a sample-selection bias arises when a dependent variable is partially observed as a result of the sample selection. This study introduces a Maximum Entropy (MaxEnt process regression model that assumes a MaxEnt prior distribution for its nonparametric regression function and finds that the MaxEnt process regression model includes the well-known Gaussian process regression (GPR model as a special case. Then, this special MaxEnt process regression model, i.e., the GPR model, is generalized to obtain a robust sample-selection Gaussian process regression (RSGPR model that deals with non-normal data in the sample selection. Various properties of the RSGPR model are established, including the stochastic representation, distributional hierarchy, and magnitude of the sample-selection bias. These properties are used in the paper to develop a hierarchical Bayesian methodology to estimate the model. This involves a simple and computationally feasible Markov chain Monte Carlo algorithm that avoids analytical or numerical derivatives of the log-likelihood function of the model. The performance of the RSGPR model in terms of the sample-selection bias correction, robustness to non-normality, and prediction, is demonstrated through results in simulations that attest to its good finite-sample performance.

  17. Surface studies of plasma processed Nb samples

    International Nuclear Information System (INIS)

    Tyagi, Puneet V.; Doleans, Marc; Hannah, Brian S.; Afanador, Ralph; Stewart, Stephen; Mammosser, John; Howell, Matthew P; Saunders, Jeffrey W; Degraff, Brian D; Kim, Sang-Ho

    2015-01-01

    Contaminants present at top surface of superconducting radio frequency (SRF) cavities can act as field emitters and restrict the cavity accelerating gradient. A room temperature in-situ plasma processing technology for SRF cavities aiming to clean hydrocarbons from inner surface of cavities has been recently developed at the Spallation Neutron Source (SNS). Surface studies of the plasma-processed Nb samples by Secondary ion mass spectrometry (SIMS) and Scanning Kelvin Probe (SKP) showed that the NeO_2 plasma processing is very effective to remove carbonaceous contaminants from top surface and improves the surface work function by 0.5 to 1.0 eV.

  18. Atmospheric Deposition: Sampling Procedures, Analytical Methods, and Main Recent Findings from the Scientific Literature

    Directory of Open Access Journals (Sweden)

    M. Amodio

    2014-01-01

    Full Text Available The atmosphere is a carrier on which some natural and anthropogenic organic and inorganic chemicals are transported, and the wet and dry deposition events are the most important processes that remove those chemicals, depositing it on soil and water. A wide variety of different collectors were tested to evaluate site-specificity, seasonality and daily variability of settleable particle concentrations. Deposition fluxes of POPs showed spatial and seasonal variations, diagnostic ratios of PAHs on deposited particles, allowed the discrimination between pyrolytic or petrogenic sources. Congener pattern analysis and bulk deposition fluxes in rural sites confirmed long-range atmospheric transport of PCDDs/Fs. More and more sophisticated and newly designed deposition samplers have being used for characterization of deposited mercury, demonstrating the importance of rain scavenging and the relatively higher magnitude of Hg deposition from Chinese anthropogenic sources. Recently biological monitors demonstrated that PAH concentrations in lichens were comparable with concentrations measured in a conventional active sampler in an outdoor environment. In this review the authors explore the methodological approaches used for the assessment of atmospheric deposition, from the analysis of the sampling methods, the analytical procedures for chemical characterization of pollutants and the main results from the scientific literature.

  19. Cytological preparations for molecular analysis: A review of technical procedures, advantages and limitations for referring samples for testing.

    Science.gov (United States)

    da Cunha Santos, G; Saieg, M A; Troncone, G; Zeppa, P

    2018-04-01

    Minimally invasive procedures such as endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) must yield not only good quality and quantity of material for morphological assessment, but also an adequate sample for analysis of molecular markers to guide patients to appropriate targeted therapies. In this context, cytopathologists worldwide should be familiar with minimum requirements for refereeing cytological samples for testing. The present manuscript is a review with comprehensive description of the content of the workshop entitled Cytological preparations for molecular analysis: pre-analytical issues for EBUS TBNA, presented at the 40th European Congress of Cytopathology in Liverpool, UK. The present review emphasises the advantages and limitations of different types of cytology substrates used for molecular analysis such as archival smears, liquid-based preparations, archival cytospin preparations and FTA (Flinders Technology Associates) cards, as well as their technical requirements/features. These various types of cytological specimens can be successfully used for an extensive array of molecular studies, but the quality and quantity of extracted nucleic acids rely directly on adequate pre-analytical assessment of those samples. In this setting, cytopathologists must not only be familiar with the different types of specimens and associated technical procedures, but also correctly handle the material provided by minimally invasive procedures, ensuring that there is sufficient amount of material for a precise diagnosis and correct management of the patient through personalised care. © 2018 John Wiley & Sons Ltd.

  20. Sample preparation in alkaline media

    International Nuclear Information System (INIS)

    Nobrega, Joaquim A.; Santos, Mirian C.; Sousa, Rafael A. de; Cadore, Solange; Barnes, Ramon M.; Tatro, Mark

    2006-01-01

    The use of tetramethylammonium hydroxide, tertiary amines and strongly alkaline reagents for sample treatment involving extraction and digestion procedures is discussed in this review. The preparation of slurries is also discussed. Based on literature data, alkaline media offer a good alternative for sample preparation involving an appreciable group of analytes in different types of samples. These reagents are also successfully employed in tailored speciation procedures wherein there is a critical dependence on maintenance of chemical forms. The effects of these reagents on measurements performed using spectroanalytical techniques are discussed. Several undesirable effects on transport and atomization processes necessitate use of the method of standard additions to obtain accurate results. It is also evident that alkaline media can improve the performance of techniques such as inductively coupled plasma mass spectrometry and accessories, such as autosamplers coupled to graphite furnace atomic absorption spectrometers

  1. Perfluoroalkyl Acid Concentrations in Blood Samples Subjected to Transportation and Processing Delay

    DEFF Research Database (Denmark)

    Bach, Cathrine Carlsen; Henriksen, Tine Brink; Bossi, Rossana

    2015-01-01

    and transportation prior to processing and samples with immediate processing and freezing. METHODS: Pregnant women recruited at Aarhus University Hospital, Denmark, (n = 88) provided paired blood samples. For each pair of samples, one was immediately processed and plasma was frozen, and the other was delayed...... and transported as whole blood before processing and freezing of plasma (similar to the Danish National Birth Cohort). We measured 12 perfluoroalkyl acids and present results for compounds with more than 50% of samples above the lower limit of quantification. RESULTS: For samples taken in the winter, relative...... differences between the paired samples ranged between -77 and +38% for individual perfluoroalkyl acids. In most cases concentrations were lower in the delayed and transported samples, e.g. the relative difference was -29% (95% confidence interval -30; -27) for perfluorooctane sulfonate. For perfluorooctanoate...

  2. Experiences with preventive procedures application in the process of beer production in Czech Republic

    OpenAIRE

    Jana Kotovicová; František Toman; Magdalena Vaverková

    2011-01-01

    Food-processing industry is an intriguing field regarding prevention procedures application. All food-processing operations have common fundamental spheres of problems – wastewater polluted by organic substances, solid waste of biological origin and losses during source material processing. Beer production process is a representative of food-processing sphere. The brewing industry has an ancient tradition and is still a dynamic sector open to new developments in technology and scientific prog...

  3. Computerized procedures system

    Science.gov (United States)

    Lipner, Melvin H.; Mundy, Roger A.; Franusich, Michael D.

    2010-10-12

    An online data driven computerized procedures system that guides an operator through a complex process facility's operating procedures. The system monitors plant data, processes the data and then, based upon this processing, presents the status of the current procedure step and/or substep to the operator. The system supports multiple users and a single procedure definition supports several interface formats that can be tailored to the individual user. Layered security controls access privileges and revisions are version controlled. The procedures run on a server that is platform independent of the user workstations that the server interfaces with and the user interface supports diverse procedural views.

  4. Development of SRC-I product analysis. Volume 3. Documentation of procedures

    Energy Technology Data Exchange (ETDEWEB)

    Schweighardt, F.K.; Kingsley, I.S.; Cooper, F.E.; Kamzelski, A.Z.; Parees, D.M.

    1983-09-01

    This section documents the BASIC computer program written to simulate Wilsonville's GC-simulated distillation (GCSD) results at APCI-CRSD Trexlertown. The GC conditions used at APCI for the Wilsonville GCSD analysis of coal-derived liquid samples were described in the SRC-I Quarterly Technical Report, April-June 1981. The approach used to simulate the Wilsonville GCSD results is also from an SRC-I Quarterly Technical Report and is reproduced in Appendix VII-A. The BASIC computer program is described in the attached Appendix VII-B. Analysis of gases produced during coal liquefaction generates key information needed to determine product yields for material balance and process control. Gas samples from the coal process development unit (CPDU) and tubing bombs are the primary samples analyzed. A Carle gas chromatographic system was used to analyze coal liquefaction gas samples. A BASIC computer program was written to calculate the gas chromatographic peak area results into mole percent results. ICRC has employed several analytical workup procedures to determine the amount of distillate, oils, asphaltenes, preasphaltenes, and residue in SRC-I process streams. The ASE procedure was developed using Conoco's liquid column fractionation (LC/F) method as a model. In developing the ASE procedure, ICRC was able to eliminate distillation, and therefore quantify the oils fraction in one extraction step. ASE results were shown to be reproducible within +- 2 wt %, and to yield acceptable material balances. Finally, the ASE method proved to be the least affected by sample composition.

  5. Why unbiased computational processes can lead to discriminative decision procedures (Chapter 3)

    NARCIS (Netherlands)

    Calders, T.G.K.; Zliobaite, I.; Custers, B.H.M.; Calders, T.G.K.; Schermer, B.W.; Zarsky, T.Z.

    2013-01-01

    Nowadays, more and more decision procedures are supported or even guided by automated processes. An important technique in this automation is data mining. In this chapter we study how such automatically generated decision support models may exhibit discriminatory behavior towards certain groups

  6. Real-time recursive hyperspectral sample and band processing algorithm architecture and implementation

    CERN Document Server

    Chang, Chein-I

    2017-01-01

    This book explores recursive architectures in designing progressive hyperspectral imaging algorithms. In particular, it makes progressive imaging algorithms recursive by introducing the concept of Kalman filtering in algorithm design so that hyperspectral imagery can be processed not only progressively sample by sample or band by band but also recursively via recursive equations. This book can be considered a companion book of author’s books, Real-Time Progressive Hyperspectral Image Processing, published by Springer in 2016. Explores recursive structures in algorithm architecture Implements algorithmic recursive architecture in conjunction with progressive sample and band processing Derives Recursive Hyperspectral Sample Processing (RHSP) techniques according to Band-Interleaved Sample/Pixel (BIS/BIP) acquisition format Develops Recursive Hyperspectral Band Processing (RHBP) techniques according to Band SeQuential (BSQ) acquisition format for hyperspectral data.

  7. Improved monitoring procedure for Iodine -131 in radiochemical process laboratory

    International Nuclear Information System (INIS)

    Singh, Pratap; Yadav, R.K.B.; Anilkumar, S.; Gopalakrishnan, R.K.; Chakraborty, S.

    2016-01-01

    Radiation Hazard Control Unit at Isotope wing provides radiological safety support and advises for safe processing and production of radiopharmaceuticals. Tellurium Oxide (TeO 2 ), irradiated in a nuclear reactor, is processed in a process laboratory for separating 131 I using dry distillation technique. The workplace environment is being assessed for airborne radioactivity using installed Static Air Samplers (SASs). SASs contains two filter media (glass fibre and charcoal impregnated paper) to collect airborne 131 I radioactivity and laboratory air sampled at 50 litres per minutes (lpm). Personal Air Sampler (PAS) consists of three types of filters viz. a glass fibre, charcoal impregnated paper and cartridges containing activated charcoal granules. Three combinations were studied at a sampling rate of 5 lpm

  8. Sample-size effects in fast-neutron gamma-ray production measurements: solid-cylinder samples

    International Nuclear Information System (INIS)

    Smith, D.L.

    1975-09-01

    The effects of geometry, absorption and multiple scattering in (n,Xγ) reaction measurements with solid-cylinder samples are investigated. Both analytical and Monte-Carlo methods are employed in the analysis. Geometric effects are shown to be relatively insignificant except in definition of the scattering angles. However, absorption and multiple-scattering effects are quite important; accurate microscopic differential cross sections can be extracted from experimental data only after a careful determination of corrections for these processes. The results of measurements performed using several natural iron samples (covering a wide range of sizes) confirm validity of the correction procedures described herein. It is concluded that these procedures are reliable whenever sufficiently accurate neutron and photon cross section and angular distribution information is available for the analysis. (13 figures, 5 tables) (auth)

  9. Recruitment and Selection of Foreign Professionals In the South African Job Market: Procedures and Processes

    Directory of Open Access Journals (Sweden)

    Chao Nkhungulu Mulenga

    2007-07-01

    Full Text Available This study investigated procedures and processes used in the selection of prospective foreign applicants by recruitment agencies in South Africa. An electronic survey was distributed to the accessible population of 244 agencies on a national employment website, yielding 57 respondents. The results indicate that the recruitment industry does not have standard, well articulated procedures for identifying and selecting prospective foreign employees and considered processing foreign applicants difficult. Difficulties with the Department of Home Affairs were a major hindrance to recruiting foreign applicants.

  10. 75 FR 50713 - Procedural Changes to the Fire Management Assistance Declaration Process

    Science.gov (United States)

    2010-08-17

    ... DEPARTMENT OF HOMELAND SECURITY Federal Emergency Management Agency 44 CFR Part 204 [Docket ID FEMA-2010-0036] RIN-1660-AA72 Procedural Changes to the Fire Management Assistance Declaration Process AGENCY: Federal Emergency Management Agency, DHS. ACTION: Final rule. SUMMARY: By this final rule, the...

  11. The interprocess NIR sampling as an alternative approach to multivariate statistical process control for identifying sources of product-quality variability.

    Science.gov (United States)

    Marković, Snežana; Kerč, Janez; Horvat, Matej

    2017-03-01

    We are presenting a new approach of identifying sources of variability within a manufacturing process by NIR measurements of samples of intermediate material after each consecutive unit operation (interprocess NIR sampling technique). In addition, we summarize the development of a multivariate statistical process control (MSPC) model for the production of enteric-coated pellet product of the proton-pump inhibitor class. By developing provisional NIR calibration models, the identification of critical process points yields comparable results to the established MSPC modeling procedure. Both approaches are shown to lead to the same conclusion, identifying parameters of extrusion/spheronization and characteristics of lactose that have the greatest influence on the end-product's enteric coating performance. The proposed approach enables quicker and easier identification of variability sources during manufacturing process, especially in cases when historical process data is not straightforwardly available. In the presented case the changes of lactose characteristics are influencing the performance of the extrusion/spheronization process step. The pellet cores produced by using one (considered as less suitable) lactose source were on average larger and more fragile, leading to consequent breakage of the cores during subsequent fluid bed operations. These results were confirmed by additional experimental analyses illuminating the underlying mechanism of fracture of oblong pellets during the pellet coating process leading to compromised film coating.

  12. Evaluation of a New Automated Processing System (TACAS™ Pro) for Liquid-Based Procedures.

    Science.gov (United States)

    Kuramoto, Hiroyuki; Sugimoto, Naoko; Iwami, Yoshiko; Kato, Chizuyo; Hori, Masuko; Iida, Manichi

    2015-01-01

    To evaluate a fully automated processing system (TACAS™ Pro) for liquid-based procedures (LBPs). Materials were 3,483 and additionally 502 specimens that were taken at Kanagawa Health Service Association. Specimens obtained with a Cervex-Brush® were first smeared to glass slides using one side of the brush and then processed to TACAS Pro. (1) The microscopy watching time per normal case was 3.65 ± 0.85 min in the conventional procedure, whereas in the LBP it was 1.95 ± 0.60 min, and the latter reduced workload to 53%. (2) The handling time of TACAS Pro per day was 2 h and 25.8 min. The workload at a laboratory offset it and revealed the work saving to be 63.8%. (3) Unsatisfactory rates were 0% in the conventional procedure, whereas in the LBP it was 1.88% at first. The latter rate decreased to 0.5% after system improvement. (4) Specimens which may disturb microscopy analysis were found in 1.06%, including 3 cases of possible carry-over of cells to the following slides. An additional study with the revised system confirmed no carry-over. (5) Incidences of abnormal cytology were consistent between the two methods. The revised automated processing system TACAS Pro is a feasible and useful LBP and reduces the workload of cytology laboratories. © 2015 S. Karger AG, Basel.

  13. Establishing Reliable Cognitive Change in Children with Epilepsy: The Procedures and Results for a Sample with Epilepsy

    Science.gov (United States)

    van Iterson, Loretta; Augustijn, Paul B.; de Jong, Peter F.; van der Leij, Aryan

    2013-01-01

    The goal of this study was to investigate reliable cognitive change in epilepsy by developing computational procedures to determine reliable change index scores (RCIs) for the Dutch Wechsler Intelligence Scales for Children. First, RCIs were calculated based on stability coefficients from a reference sample. Then, these RCIs were applied to a…

  14. Membrane biofouling characterization: effects of sample preparation procedures on biofilm structure and the microbial community

    KAUST Repository

    Xue, Zheng

    2014-07-15

    Ensuring the quality and reproducibility of results from biofilm structure and microbial community analysis is essential to membrane biofouling studies. This study evaluated the impacts of three sample preparation factors (ie number of buffer rinses, storage time at 4°C, and DNA extraction method) on the downstream analysis of nitrifying biofilms grown on ultrafiltration membranes. Both rinse and storage affected biofilm structure, as suggested by their strong correlation with total biovolume, biofilm thickness, roughness and the spatial distribution of EPS. Significant variations in DNA yields and microbial community diversity were also observed among samples treated by different rinses, storage and DNA extraction methods. For the tested biofilms, two rinses, no storage and DNA extraction with both mechanical and chemical cell lysis from attached biofilm were the optimal sample preparation procedures for obtaining accurate information about biofilm structure, EPS distribution and the microbial community. © 2014 © 2014 Taylor & Francis.

  15. Gas chromatographic-mass spectrometric analysis of urinary volatile organic metabolites: Optimization of the HS-SPME procedure and sample storage conditions.

    Science.gov (United States)

    Živković Semren, Tanja; Brčić Karačonji, Irena; Safner, Toni; Brajenović, Nataša; Tariba Lovaković, Blanka; Pizent, Alica

    2018-01-01

    Non-targeted metabolomics research of human volatile urinary metabolome can be used to identify potential biomarkers associated with the changes in metabolism related to various health disorders. To ensure reliable analysis of urinary volatile organic metabolites (VOMs) by gas chromatography-mass spectrometry (GC-MS), parameters affecting the headspace-solid phase microextraction (HS-SPME) procedure have been evaluated and optimized. The influence of incubation and extraction temperatures and times, coating fibre material and salt addition on SPME efficiency was investigated by multivariate optimization methods using reduced factorial and Doehlert matrix designs. The results showed optimum values for temperature to be 60°C, extraction time 50min, and incubation time 35min. The proposed conditions were applied to investigate urine samples' stability regarding different storage conditions and freeze-thaw processes. The sum of peak areas of urine samples stored at 4°C, -20°C, and -80°C up to six months showed a time dependent decrease over time although storage at -80°C resulted in a slight non-significant reduction comparing to the fresh sample. However, due to the volatile nature of the analysed compounds, more than two cycles of freezing/thawing of the sample stored for six months at -80°C should be avoided whenever possible. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Procedure for the Management control with process approach at the Dairy Products Company Río Zaza Sancti Spiritus.

    Directory of Open Access Journals (Sweden)

    Madelaine Herrera Carriles

    2013-03-01

    Full Text Available In this research work we propose a procedure for the management control with process approaches to quality continuing improvement approaches at the Dairy Products Company Río Zaza Sancti Spíritus. Improvement opportunities were detected after measuring economical and productive parameters of commercialization process. The procedure includes techniques and tools such as Kendall coefficient, questionnaire, SWOT matrix (Weaknesses, Threats, Strengths, Opportunities, process management, process map, flow diagrams, process chip, Pareto diagram, strategic alignment matrix, balanced scorecard and the Deming cycle. The integration of strategic deployment, the process approaches; balanced scorecard in the procedure of management control contributed to the continuous improvement of quality evaluated by means of the indicators monitoring. It was possible to lower the billing cycle to 45 days and to have an increment of 2.2 MP from the total revenues.

  17. Perfluoroalkyl Acid Concentrations in Blood Samples Subjected to Transportation and Processing Delay.

    Science.gov (United States)

    Bach, Cathrine Carlsen; Henriksen, Tine Brink; Bossi, Rossana; Bech, Bodil Hammer; Fuglsang, Jens; Olsen, Jørn; Nohr, Ellen Aagaard

    2015-01-01

    In studies of perfluoroalkyl acids, the validity and comparability of measured concentrations may be affected by differences in the handling of biospecimens. We aimed to investigate whether measured plasma levels of perfluoroalkyl acids differed between blood samples subjected to delay and transportation prior to processing and samples with immediate processing and freezing. Pregnant women recruited at Aarhus University Hospital, Denmark, (n = 88) provided paired blood samples. For each pair of samples, one was immediately processed and plasma was frozen, and the other was delayed and transported as whole blood before processing and freezing of plasma (similar to the Danish National Birth Cohort). We measured 12 perfluoroalkyl acids and present results for compounds with more than 50% of samples above the lower limit of quantification. For samples taken in the winter, relative differences between the paired samples ranged between -77 and +38% for individual perfluoroalkyl acids. In most cases concentrations were lower in the delayed and transported samples, e.g. the relative difference was -29% (95% confidence interval -30; -27) for perfluorooctane sulfonate. For perfluorooctanoate there was no difference between the two setups [corresponding estimate 1% (0, 3)]. Differences were negligible in the summer for all compounds. Transport of blood samples and processing delay, similar to conditions applied in some large, population-based studies, may affect measured perfluoroalkyl acid concentrations, mainly when outdoor temperatures are low. Attention to processing conditions is needed in studies of perfluoroalkyl acid exposure in humans.

  18. An Automated Sample Processing System for Planetary Exploration

    Science.gov (United States)

    Soto, Juancarlos; Lasnik, James; Roark, Shane; Beegle, Luther

    2012-01-01

    An Automated Sample Processing System (ASPS) for wet chemistry processing of organic materials on the surface of Mars has been jointly developed by Ball Aerospace and the Jet Propulsion Laboratory. The mechanism has been built and tested to demonstrate TRL level 4. This paper describes the function of the system, mechanism design, lessons learned, and several challenges that were overcome.

  19. 15 CFR 400.32 - Procedure for review of request for approval of manufacturing or processing.

    Science.gov (United States)

    2010-01-01

    ... approval of manufacturing or processing. 400.32 Section 400.32 Commerce and Foreign Trade Regulations... REGULATIONS OF THE FOREIGN-TRADE ZONES BOARD Manufacturing and Processing Activity-Reviews § 400.32 Procedure for review of request for approval of manufacturing or processing. (a) Request as part of application...

  20. Continuous quality control of the blood sampling procedure using a structured observation scheme.

    Science.gov (United States)

    Seemann, Tine Lindberg; Nybo, Mads

    2016-10-15

    An observational study was conducted using a structured observation scheme to assess compliance with the local phlebotomy guideline, to identify necessary focus items, and to investigate whether adherence to the phlebotomy guideline improved. The questionnaire from the EFLM Working Group for the Preanalytical Phase was adapted to local procedures. A pilot study of three months duration was conducted. Based on this, corrective actions were implemented and a follow-up study was conducted. All phlebotomists at the Department of Clinical Biochemistry and Pharmacology were observed. Three blood collections by each phlebotomist were observed at each session conducted at the phlebotomy ward and the hospital wards, respectively. Error frequencies were calculated for the phlebotomy ward and the hospital wards and for the two study phases. A total of 126 blood drawings by 39 phlebotomists were observed in the pilot study, while 84 blood drawings by 34 phlebotomists were observed in the follow-up study. In the pilot study, the three major error items were hand hygiene (42% error), mixing of samples (22%), and order of draw (21%). Minor significant differences were found between the two settings. After focus on the major aspects, the follow-up study showed significant improvement for all three items at both settings (P < 0.01, P < 0.01, and P = 0.01, respectively). Continuous quality control of the phlebotomy procedure revealed a number of items not conducted in compliance with the local phlebotomy guideline. It supported significant improvements in the adherence to the recommended phlebotomy procedures and facilitated documentation of the phlebotomy quality.

  1. Rapid Automated Dissolution and Analysis Techniques for Radionuclides in Recycle Process Streams

    International Nuclear Information System (INIS)

    Sudowe, Ralf; Roman, Audrey; Dailey, Ashlee; Go, Elaine

    2013-01-01

    The analysis of process samples for radionuclide content is an important part of current procedures for material balance and accountancy in the different process streams of a recycling plant. The destructive sample analysis techniques currently available necessitate a significant amount of time. It is therefore desirable to develop new sample analysis procedures that allow for a quick turnaround time and increased sample throughput with a minimum of deviation between samples. In particular, new capabilities for rapid sample dissolution and radiochemical separation are required. Most of the radioanalytical techniques currently employed for sample analysis are based on manual laboratory procedures. Such procedures are time- and labor-intensive, and not well suited for situations in which a rapid sample analysis is required and/or large number of samples need to be analyzed. To address this issue we are currently investigating radiochemical separation methods based on extraction chromatography that have been specifically optimized for the analysis of process stream samples. The influence of potential interferences present in the process samples as well as mass loading, flow rate and resin performance is being studied. In addition, the potential to automate these procedures utilizing a robotic platform is evaluated. Initial studies have been carried out using the commercially available DGA resin. This resin shows an affinity for Am, Pu, U, and Th and is also exhibiting signs of a possible synergistic effects in the presence of iron.

  2. Dual Systems Competence [Image Omitted] Procedural Processing: A Relational Developmental Systems Approach to Reasoning

    Science.gov (United States)

    Ricco, Robert B.; Overton, Willis F.

    2011-01-01

    Many current psychological models of reasoning minimize the role of deductive processes in human thought. In the present paper, we argue that deduction is an important part of ordinary cognition and we propose that a dual systems Competence [image omitted] Procedural processing model conceptualized within relational developmental systems theory…

  3. 40 CFR 63.645 - Test methods and procedures for miscellaneous process vents.

    Science.gov (United States)

    2010-07-01

    ... analysis based on accepted chemical engineering principles, measurable process parameters, or physical or... for a new source, Method 18 may be used to determine any non-VOC hydrocarbons that may be deducted to calculate the TOC (minus non-VOC hydrocarbons) concentration and mass flow rate. The following procedures...

  4. Which Procedural Parts of the IEP Process Are the Most Judicially Vulnerable?

    Science.gov (United States)

    Zirkel, Perry A.; Hetrick, Allyse

    2017-01-01

    To provide a missing piece to the legal foundation of professional development and practice for the individualized education program (IEP) process, the authors report the results of a comprehensive systematic analysis of court decisions specific to IEP-related procedural violations after the 2004 amendments of the Individuals With Disabilities…

  5. An integrated approach for multi-level sample size determination

    International Nuclear Information System (INIS)

    Lu, M.S.; Teichmann, T.; Sanborn, J.B.

    1997-01-01

    Inspection procedures involving the sampling of items in a population often require steps of increasingly sensitive measurements, with correspondingly smaller sample sizes; these are referred to as multilevel sampling schemes. In the case of nuclear safeguards inspections verifying that there has been no diversion of Special Nuclear Material (SNM), these procedures have been examined often and increasingly complex algorithms have been developed to implement them. The aim in this paper is to provide an integrated approach, and, in so doing, to describe a systematic, consistent method that proceeds logically from level to level with increasing accuracy. The authors emphasize that the methods discussed are generally consistent with those presented in the references mentioned, and yield comparable results when the error models are the same. However, because of its systematic, integrated approach the proposed method elucidates the conceptual understanding of what goes on, and, in many cases, simplifies the calculations. In nuclear safeguards inspections, an important aspect of verifying nuclear items to detect any possible diversion of nuclear fissile materials is the sampling of such items at various levels of sensitivity. The first step usually is sampling by ''attributes'' involving measurements of relatively low accuracy, followed by further levels of sampling involving greater accuracy. This process is discussed in some detail in the references given; also, the nomenclature is described. Here, the authors outline a coordinated step-by-step procedure for achieving such multilevel sampling, and they develop the relationships between the accuracy of measurement and the sample size required at each stage, i.e., at the various levels. The logic of the underlying procedures is carefully elucidated; the calculations involved and their implications, are clearly described, and the process is put in a form that allows systematic generalization

  6. Reviving Markov processes and applications

    International Nuclear Information System (INIS)

    Cai, H.

    1988-01-01

    In this dissertation we study a procedure which restarts a Markov process when the process is killed by some arbitrary multiplicative functional. The regenerative nature of this revival procedure is characterized through a Markov renewal equation. An interesting duality between the revival procedure and the classical killing operation is found. Under the condition that the multiplicative functional possesses an intensity, the generators of the revival process can be written down explicitly. An intimate connection is also found between the perturbation of the sample path of a Markov process and the perturbation of a generator (in Kato's sense). The applications of the theory include the study of the processes like piecewise-deterministic Markov process, virtual waiting time process and the first entrance decomposition (taboo probability)

  7. Sample processing method for the determination of perchlorate in milk

    International Nuclear Information System (INIS)

    Dyke, Jason V.; Kirk, Andrea B.; Kalyani Martinelango, P.; Dasgupta, Purnendu K.

    2006-01-01

    In recent years, many different water sources and foods have been reported to contain perchlorate. Studies indicate that significant levels of perchlorate are present in both human and dairy milk. The determination of perchlorate in milk is particularly important due to its potential health impact on infants and children. As for many other biological samples, sample preparation is more time consuming than the analysis itself. The concurrent presence of large amounts of fats, proteins, carbohydrates, etc., demands some initial cleanup; otherwise the separation column lifetime and the limit of detection are both greatly compromised. Reported milk processing methods require the addition of chemicals such as ethanol, acetic acid or acetonitrile. Reagent addition is undesirable in trace analysis. We report here an essentially reagent-free sample preparation method for the determination of perchlorate in milk. Milk samples are spiked with isotopically labeled perchlorate and centrifuged to remove lipids. The resulting liquid is placed in a disposable centrifugal ultrafilter device with a molecular weight cutoff of 10 kDa, and centrifuged. Approximately 5-10 ml of clear liquid, ready for analysis, is obtained from a 20 ml milk sample. Both bovine and human milk samples have been successfully processed and analyzed by ion chromatography-mass spectrometry (IC-MS). Standard addition experiments show good recoveries. The repeatability of the analytical result for the same sample in multiple sample cleanup runs ranged from 3 to 6% R.S.D. This processing technique has also been successfully applied for the determination of iodide and thiocyanate in milk

  8. A radiochemical procedure for a low-level measurement of ''241Am in environmental samples using a supported functional organo phosphorus extractant

    International Nuclear Information System (INIS)

    Gasco, C.; Anton, M. P.; Alvarez, A.; Navarro, N.; Salvador, S.

    1994-01-01

    The transuranides analysis in environmental samples is carried out by CIEMAT using standardized methods based on sequential separation with ionic-exchange resins. The americium fraction is purified through a two-layer ion exchange column and lately in an anion-exchange column in nitric acid methanol medium. The technique is time consuming and the results are not completely satisfactory (low recovery and loss of a-resolution) for some samples. The chemical compound CMPO (octyl(phenyl)-N,N-diisobutyl carbomoylmethyiphosphine oxide) dissolved in TPB (tributyl phosphate) and supported on an inert substrate has been tested directly for ''241Am analysis by a large number of laboratories. A new method that combines both procedures has been developed. The details of the improved procedure are described in this paper. The advantages of its application to environmental samples (urine, faeces and sediments) are discussed. The utilization of standard samples, with americium certified concentrations confirms the reliability of our measurements. (Author) 8 refs

  9. HASL procedures manual

    International Nuclear Information System (INIS)

    Harley, J.H.

    1977-08-01

    Additions and corrections to the following sections of the HASL Procedures Manual are provided: General, Sampling, Field Measurements; General Analytical Chemistry, Chemical Procedures, Data Section, and Specifications

  10. 47 CFR 22.921 - 911 call processing procedures; 911-only calling mode.

    Science.gov (United States)

    2010-10-01

    ... programming in the mobile unit that determines the handling of a non-911 call and permit the call to be... CARRIER SERVICES PUBLIC MOBILE SERVICES Cellular Radiotelephone Service § 22.921 911 call processing procedures; 911-only calling mode. Mobile telephones manufactured after February 13, 2000 that are capable of...

  11. Procedure-related risk of miscarriage following amniocentesis and chorionic villus sampling: a systematic review and meta-analysis.

    Science.gov (United States)

    Akolekar, R; Beta, J; Picciarelli, G; Ogilvie, C; D'Antonio, F

    2015-01-01

    To estimate procedure-related risks of miscarriage following amniocentesis and chorionic villus sampling (CVS) based on a systematic review of the literature and a meta-analysis. A search of MEDLINE, EMBASE, CINHAL and The Cochrane Library (2000-2014) was performed to review relevant citations reporting procedure-related complications of amniocentesis and CVS. Only studies reporting data on more than 1000 procedures were included in this review to minimize the effect of bias from smaller studies. Heterogeneity between studies was estimated using Cochran's Q, the I(2) statistic and Egger bias. Meta-analysis of proportions was used to derive weighted pooled estimates for the risk of miscarriage before 24 weeks' gestation. Incidence-rate difference meta-analysis was used to estimate pooled procedure-related risks. The weighted pooled risks of miscarriage following invasive procedures were estimated from analysis of controlled studies including 324 losses in 42 716 women who underwent amniocentesis and 207 losses in 8899 women who underwent CVS. The risk of miscarriage prior to 24 weeks in women who underwent amniocentesis and CVS was 0.81% (95% CI, 0.58-1.08%) and 2.18% (95% CI, 1.61-2.82%), respectively. The background rates of miscarriage in women from the control group that did not undergo any procedures were 0.67% (95% CI, 0.46-0.91%) for amniocentesis and 1.79% (95% CI, 0.61-3.58%) for CVS. The weighted pooled procedure-related risks of miscarriage for amniocentesis and CVS were 0.11% (95% CI, -0.04 to 0.26%) and 0.22% (95% CI, -0.71 to 1.16%), respectively. The procedure-related risks of miscarriage following amniocentesis and CVS are much lower than are currently quoted. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  12. Testing results of Monte Carlo sampling processes in MCSAD

    International Nuclear Information System (INIS)

    Pinnera, I.; Cruz, C.; Abreu, Y.; Leyva, A.; Correa, C.; Demydenko, C.

    2009-01-01

    The Monte Carlo Simulation of Atom Displacements (MCSAD) is a code implemented by the authors to simulate the complete process of atom displacement (AD) formation. This code makes use of the Monte Carlo (MC) method to sample all the processes involved in the gamma and electronic radiation transport through matter. The kernel of the calculations applied to this code relies on a model based on an algorithm developed by the authors, which firstly splits out multiple electron elastic scattering events from those single ones at higher scattering angles and then, from the last one, sampling those leading to AD at high transferred atomic recoil energies. Some tests have been developed to check the sampling algorithms with the help of the corresponding theoretical distribution functions. Satisfactory results have been obtained, which indicate the strength of the methods and subroutines used in the code. (Author)

  13. 39 CFR 230.26 - Do these rules affect the service of process requirements of the Federal Rules of Civil Procedure...

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Do these rules affect the service of process....26 Do these rules affect the service of process requirements of the Federal Rules of Civil Procedure... Rules of Civil Procedure regarding service of process. ...

  14. Integrated preservation and sample clean up procedures for studying water ingestion by recreational swimmers via urinary biomarker determination.

    Science.gov (United States)

    Cantú, Ricardo; Shoemaker, Jody A; Kelty, Catherine A; Wymer, Larry J; Behymer, Thomas D; Dufour, Alfred P; Magnuson, Matthew L

    2017-08-22

    The use of cyanuric acid as a biomarker for ingestion of swimming pool water may lead to quantitative knowledge of the volume of water ingested during swimming, contributing to a better understanding of disease resulting from ingestion of environmental contaminants. When swimming pool water containing chlorinated cyanurates is inadvertently ingested, cyanuric acid is excreted quantitatively within 24 h as a urinary biomarker of ingestion. Because the volume of water ingested can be quantitatively estimated by calculation from the concentration of cyanuric acid in 24 h urine samples, a procedure for preservation, cleanup, and analysis of cyanuric acid was developed to meet the logistical demands of large scale studies. From a practical stand point, urine collected from swimmers cannot be analyzed immediately, given requirements of sample collection, shipping, handling, etc. Thus, to maintain quality control to allow confidence in the results, it is necessary to preserve the samples in a manner that ensures as quantitative analysis as possible. The preservation and clean-up of cyanuric acid in urine is complicated because typical approaches often are incompatible with the keto-enol tautomerization of cyanuric acid, interfering with cyanuric acid sample preparation, chromatography, and detection. Therefore, this paper presents a novel integration of sample preservation, clean-up, chromatography, and detection to determine cyanuric acid in 24 h urine samples. Fortification of urine with cyanuric acid (0.3-3.0 mg/L) demonstrated accuracy (86-93% recovery) and high reproducibility (RSD urine suggested sufficient cyanuric acid stability for sample collection procedures, while longer holding times suggested instability of the unpreserved urine. Preserved urine exhibited a loss of around 0.5% after 22 days at refrigerated storage conditions of 4 °C. Published by Elsevier B.V.

  15. A very sensitive LSC procedure to determine Ni-63 in environmental samples, steel and concrete

    International Nuclear Information System (INIS)

    Scheuerer, C.; Schupfner, R.; Schuettelkopf, H.

    1995-01-01

    This procedure to determine Ni-63 contributes to a safe and economically reasonable decommissioning of nuclear power plants. Co-60, Fe-55 and Ni-63 are the most abundant long-lived radionuclides associated with contaminated piping, hardware and concrete for a period of several decades of years after shutdown. Samples are carefully ashed leached, or dissolved by suitable mixtures of acids. The analysis starts with the absorption Ni 2+ on the chelating resin CHELEX 100. The next purification steps include an anionic exchange column and a precipitation as Ni-dimethyl-glyoxime, which is extracted into chloroform. After reextraction with sulfuric acid the solution containing Ni 2+ is mixed with a scintillation cocktail and counted in an anticoincidence shielded LSC. The decontamination factors are determined for all important artificially and naturally occurring radionuclides ranging form above 10 4 to 10 9 . The chemical yield adopts a value of (95±5)%. Up to maximum sample amounts of 0.4 g steel, 5 g concrete and about 100 g of environmental samples the detection limits are about 5 mBq per sample or 12 mBq/g steel, 1 mBq/g concrete and 0.05 mBq/g environmental sample at a counting time of 1000 minutes. (author) 16 refs.; 2 figs.; 2 tabs

  16. Capillary absorption spectrometer and process for isotopic analysis of small samples

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, M. Lizabeth; Kelly, James F.; Sams, Robert L.; Moran, James J.; Newburn, Matthew K.; Blake, Thomas A.

    2018-04-24

    A capillary absorption spectrometer and process are described that provide highly sensitive and accurate stable absorption measurements of analytes in a sample gas that may include isotopologues of carbon and oxygen obtained from gas and biological samples. It further provides isotopic images of microbial communities that allow tracking of nutrients at the single cell level. It further targets naturally occurring variations in carbon and oxygen isotopes that avoids need for expensive isotopically labeled mixtures which allows study of samples taken from the field without modification. The process also permits sampling in vivo permitting real-time ambient studies of microbial communities.

  17. Development of procedure using plasma welding process to produce 125I seeds

    International Nuclear Information System (INIS)

    Feher, Anselmo

    2006-01-01

    The prostate cancer, which is the second cause of death by cancer in men, overcome only by lung cancer, is a problem of public health in Brazil. Brachytherapy is among the possible available treatments for prostate cancer, in which small seeds containing 125 I radioisotope are implanted in the prostate. The seed consists of a titanium sealed capsule with 0.8 mm external diameter and 4.5 mm length, containing a central silver wire with adsorbed 125 I. The plasma arc welding is one of the viable techniques for the sealing process. The equipment used in this technique is less costly than in other processes. The main objective of this work was the development and the validation of the welding procedure using plasma welding process and the elaboration of a sealing routine according to Good Manufacturing Practices. The development of this work has presented the following phases: cut and cleaning of the titanium material, determination of the welding parameters, development of a device for holding the titanium tube during the welding process, validation of sealed sources according to ISO 2919 Sealed Radioactive Sources - General Requirements and Classification, leakage test according to ISO 9978 Sealed Radioactive Sources - Leakage Test Methods and metallographic assays. The developed procedure, to seal 125 I seeds using plasma welding process, has shown to be efficient, satisfying all the established requirements of ISO 2919. The results obtained in this work have given the possibility to establish a routine production process according to the orientations presented in resolution RDC number 59 - Good Manufacturing Practices do Medical Products of the ANVISA - Brazilian Nacional Agency of Sanitary Surveillance. (author)

  18. Quantitating morphological changes in biological samples during scanning electron microscopy sample preparation with correlative super-resolution microscopy.

    Science.gov (United States)

    Zhang, Ying; Huang, Tao; Jorgens, Danielle M; Nickerson, Andrew; Lin, Li-Jung; Pelz, Joshua; Gray, Joe W; López, Claudia S; Nan, Xiaolin

    2017-01-01

    Sample preparation is critical to biological electron microscopy (EM), and there have been continuous efforts on optimizing the procedures to best preserve structures of interest in the sample. However, a quantitative characterization of the morphological changes associated with each step in EM sample preparation is currently lacking. Using correlative EM and superresolution microscopy (SRM), we have examined the effects of different drying methods as well as osmium tetroxide (OsO4) post-fixation on cell morphology during scanning electron microscopy (SEM) sample preparation. Here, SRM images of the sample acquired under hydrated conditions were used as a baseline for evaluating morphological changes as the sample went through SEM sample processing. We found that both chemical drying and critical point drying lead to a mild cellular boundary retraction of ~60 nm. Post-fixation by OsO4 causes at least 40 nm additional boundary retraction. We also found that coating coverslips with adhesion molecules such as fibronectin prior to cell plating helps reduce cell distortion from OsO4 post-fixation. These quantitative measurements offer useful information for identifying causes of cell distortions in SEM sample preparation and improving current procedures.

  19. A column exchange chromatographic procedure for the automated purification of analytical samples in nuclear spent fuel reprocessing and plutonium fuel fabrication

    International Nuclear Information System (INIS)

    Zahradnik, P.; Swietly, H.; Doubek, N.; Bagliano, G.

    1992-11-01

    A Column Exchange Chromatographic procedure using Tri-n-Octyl-Phosphine-Oxide (TOPO) as stationary phase, is in routine use at SAL since 1984 on nuclear spent fuel reprocessing and on Pu product samples, prior to alpha and mass spectrometric analysis. This standard procedure was further on modified in view of its automation in a glove box; the resulting new procedure is described in this paper. Laboratory Robot Compatible (LRC) disposable columns were selected because their dimensions are particularly favorable and reproducible. A less corrosive HNO 3 -HI mixture substituted the former HC1-HI plutonium eluant. The inorganic support of the stationary phase used to test the above mentioned changes was unexpectedly withdrawn from the market so that another support had to be selected and the procedure reoptimized accordingly. The resulting procedure was tested with the robot and validated against the manual procedure taken as reference: the comparison showed that the modified procedure meets the analytical requirements and has the same performance than the original procedure. (author). Refs, figs and tabs

  20. Optimized pre-thinning procedures of ion-beam thinning for TEM sample preparation by magnetorheological polishing.

    Science.gov (United States)

    Luo, Hu; Yin, Shaohui; Zhang, Guanhua; Liu, Chunhui; Tang, Qingchun; Guo, Meijian

    2017-10-01

    Ion-beam-thinning is a well-established sample preparation technique for transmission electron microscopy (TEM), but tedious procedures and labor consuming pre-thinning could seriously reduce its efficiency. In this work, we present a simple pre-thinning technique by using magnetorheological (MR) polishing to replace manual lapping and dimpling, and demonstrate the successful preparation of electron-transparent single crystal silicon samples after MR polishing and single-sided ion milling. Dimples pre-thinned to less than 30 microns and with little mechanical surface damage were repeatedly produced under optimized MR polishing conditions. Samples pre-thinned by both MR polishing and traditional technique were ion-beam thinned from the rear side until perforation, and then observed by optical microscopy and TEM. The results show that the specimen pre-thinned by MR technique was free from dimpling related defects, which were still residual in sample pre-thinned by conventional technique. Nice high-resolution TEM images could be acquired after MR polishing and one side ion-thinning. MR polishing promises to be an adaptable and efficient method for pre-thinning in preparation of TEM specimens, especially for brittle ceramics. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Anxiety-linked attentional bias and its modification: Illustrating the importance of distinguishing processes and procedures in experimental psychopathology research.

    Science.gov (United States)

    MacLeod, Colin; Grafton, Ben

    2016-11-01

    In this review of research concerning anxiety-linked attentional bias, we seek to illustrate a general principle that we contend applies across the breadth of experimental psychopathology. Specifically, we highlight how maintenance of a clear distinction between process and procedure serves to enhance the advancement of knowledge and understanding, while failure to maintain this distinction can foster confusion and misconception. We show how such clear differentiation has permitted the continuous refinement of assessment procedures, in ways that have led to growing confidence in the existence of the putative attentional bias process of interest, and also increasing understanding of its nature. In contrast, we show how a failure to consistently differentiate between process and procedure has contributed to confusion concerning whether or not attentional bias modification reliably alters anxiety vulnerability and dysfunction. As we demonstrate, such confusion can be avoided by distinguishing the process of attentional bias modification from the procedures that have been employed with the intention of evoking this target process. Such an approach reveals that procedures adopted with the intention of eliciting the attentional bias modification process do not always do so, but that successful evocation of the attentional bias modification process quite reliably alters anxiety symptomatology. We consider some of the specific implications for future research concerning attentional bias modification, while also pointing to the broader implications for experimental psychopathology research in general. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Possible overestimation of surface disinfection efficiency by assessment methods based on liquid sampling procedures as demonstrated by in situ quantification of spore viability.

    Science.gov (United States)

    Grand, I; Bellon-Fontaine, M-N; Herry, J-M; Hilaire, D; Moriconi, F-X; Naïtali, M

    2011-09-01

    The standard test methods used to assess the efficiency of a disinfectant applied to surfaces are often based on counting the microbial survivors sampled in a liquid, but total cell removal from surfaces is seldom achieved. One might therefore wonder whether evaluations of microbial survivors in liquid-sampled cells are representative of the levels of survivors in whole populations. The present study was thus designed to determine the "damaged/undamaged" status induced by a peracetic acid disinfection for Bacillus atrophaeus spores deposited on glass coupons directly on this substrate and to compare it to the status of spores collected in liquid by a sampling procedure. The method utilized to assess the viability of both surface-associated and liquid-sampled spores included fluorescence labeling with a combination of Syto 61 and Chemchrome V6 dyes and quantifications by analyzing the images acquired by confocal laser scanning microscopy. The principal result of the study was that the viability of spores sampled in the liquid was found to be poorer than that of surface-associated spores. For example, after 2 min of peracetic acid disinfection, less than 17% ± 5% of viable cells were detected among liquid-sampled cells compared to 79% ± 5% or 47% ± 4%, respectively, when the viability was evaluated on the surface after or without the sampling procedure. Moreover, assessments of the survivors collected in the liquid phase, evaluated using the microscopic method and standard plate counts, were well correlated. Evaluations based on the determination of survivors among the liquid-sampled cells can thus overestimate the efficiency of surface disinfection procedures.

  3. A Procedure for the Sequential Determination of Radionuclides in Environmental Samples. Liquid Scintillation Counting and Alpha Spectrometry for 90Sr, 241Am and Pu Radioisotopes

    International Nuclear Information System (INIS)

    2014-01-01

    Since 2004, IAEA activities related to the terrestrial environment have aimed at the development of a set of procedures to determine radionuclides in environmental samples. Reliable, comparable and ‘fit for purpose’ results are an essential requirement for any decision based on analytical measurements. For the analyst, tested and validated analytical procedures are extremely important tools for the production of analytical data. For maximum utility, such procedures should be comprehensive, clearly formulated and readily available for reference to both the analyst and the customer. This publication describes a combined procedure for the sequential determination of 90 Sr, 241 Am and Pu radioisotopes in environmental samples. The method is based on the chemical separation of strontium, americium and plutonium using ion exchange chromatography, extraction chromatography and precipitation followed by alpha spectrometric and liquid scintillation counting detection. The method was tested and validated in terms of repeatability and trueness in accordance with International Organization for Standardization (ISO) guidelines using reference materials and proficiency test samples. Reproducibility tests were performed later at the IAEA Terrestrial Environment Laboratory. The calculations of the massic activity, uncertainty budget, decision threshold and detection limit are also described in this publication. The procedure is introduced for the determination of 90 Sr, 241 Am and Pu radioisotopes in environmental samples such as soil, sediment, air filter and vegetation samples. It is expected to be of general use to a wide range of laboratories, including the Analytical Laboratories for the Measurement of Environmental Radioactivity (ALMERA) network for routine environmental monitoring purposes

  4. Adaptive multiple importance sampling for Gaussian processes

    Czech Academy of Sciences Publication Activity Database

    Xiong, X.; Šmídl, Václav; Filippone, M.

    2017-01-01

    Roč. 87, č. 8 (2017), s. 1644-1665 ISSN 0094-9655 R&D Projects: GA MŠk(CZ) 7F14287 Institutional support: RVO:67985556 Keywords : Gaussian Process * Bayesian estimation * Adaptive importance sampling Subject RIV: BB - Applied Statistics, Operational Research OBOR OECD: Statistics and probability Impact factor: 0.757, year: 2016 http://library.utia.cas.cz/separaty/2017/AS/smidl-0469804.pdf

  5. ACTINIDE REMOVAL PROCESS SAMPLE ANALYSIS, CHEMICAL MODELING, AND FILTRATION EVALUATION

    Energy Technology Data Exchange (ETDEWEB)

    Martino, C.; Herman, D.; Pike, J.; Peters, T.

    2014-06-05

    Filtration within the Actinide Removal Process (ARP) currently limits the throughput in interim salt processing at the Savannah River Site. In this process, batches of salt solution with Monosodium Titanate (MST) sorbent are concentrated by crossflow filtration. The filtrate is subsequently processed to remove cesium in the Modular Caustic Side Solvent Extraction Unit (MCU) followed by disposal in saltstone grout. The concentrated MST slurry is washed and sent to the Defense Waste Processing Facility (DWPF) for vitrification. During recent ARP processing, there has been a degradation of filter performance manifested as the inability to maintain high filtrate flux throughout a multi-batch cycle. The objectives of this effort were to characterize the feed streams, to determine if solids (in addition to MST) are precipitating and causing the degraded performance of the filters, and to assess the particle size and rheological data to address potential filtration impacts. Equilibrium modelling with OLI Analyzer{sup TM} and OLI ESP{sup TM} was performed to determine chemical components at risk of precipitation and to simulate the ARP process. The performance of ARP filtration was evaluated to review potential causes of the observed filter behavior. Task activities for this study included extensive physical and chemical analysis of samples from the Late Wash Pump Tank (LWPT) and the Late Wash Hold Tank (LWHT) within ARP as well as samples of the tank farm feed from Tank 49H. The samples from the LWPT and LWHT were obtained from several stages of processing of Salt Batch 6D, Cycle 6, Batch 16.

  6. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF URINE SAMPLES FOR METALS AND PESTICIDES ANALYSIS (UA-F-20.1)

    Science.gov (United States)

    The purpose of this SOP is to guide the collection, storage, and shipment of urine samples collected. This SOP provides a brief description of sample, collection, preservation, storage, shipping, and custody procedures. This procedure was followed to ensure consistent data retri...

  7. Computational integration of the phases and procedures of calibration processes for radioprotection

    International Nuclear Information System (INIS)

    Santos, Gleice R. dos; Thiago, Bibiana dos S.; Rocha, Felicia D.G.; Santos, Gelson P. dos; Potiens, Maria da Penha A.; Vivolo, Vitor

    2011-01-01

    This work proceed the computational integration of the processes phases by using only a single computational software, from the entrance of the instrument at the Instrument Calibration Laboratory (LCI-IPEN) to the conclusion of calibration procedures. So, the initial information such as trade mark, model, manufacturer, owner, and the calibration records are digitized once until the calibration certificate emission

  8. Procedures for sampling and sample-reduction within quality assurance systems for solid biofuels

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-04-15

    The bias introduced when sampling solid biofuels from stockpiles or containers instead of from moving streams is assessed as well as the number and size of samples required to represent accurately the bulk sample, variations introduced when reducing bulk samples into samples for testing, and the usefulness of sample reduction methods. Details are given of the experimental work carried out in Sweden and Denmark using sawdust, wood chips, wood pellets, forestry residues and straw. The production of a model European Standard for quality assurance of solid biofuels is examined.

  9. Minimization of the blank values in the neutron activation analysis of biological samples considering the whole procedure

    International Nuclear Information System (INIS)

    Lux, F.; Bereznai, T.; Haeberlin, T.H.

    1986-01-01

    In our determination of trace element contents of animal tissue by neutron activation analysis in the course of structure-activity relationship studies on platinum containing cancer drugs and wound healing we have tried to minimize the blank values that are caused by different sources of contamination during surgery, sampling and the activation analysis procedure. The following topics have been investigated: the abrasions from scalpels made of stainless steel, titanium or quartz; the type of surgery; the homogenisation of the samples before irradiation by use of a ball milll; the surface contaminations of the quartz ampoules that pass into the digestion solution of the irradiated samples. The appropriate measures taken in order to reduce the blank values are described. The results of analyses performed under these conditions indicate the effectiveness of the given measures, especially shown by the low values obtained for the chromium contents of the analysed muscle samples. (author)

  10. Sequential extraction procedure for determination of uranium, thorium, radium, lead and polonium radionuclides by alpha spectrometry in environmental samples

    Science.gov (United States)

    Oliveira, J. M.; Carvalho, F. P.

    2006-01-01

    A sequential extraction technique was developed and tested for common naturally-occurring radionuclides. This technique allows the extraction and purification of uranium, thorium, radium, lead, and polonium radionuclides from the same sample. Environmental materials such as water, soil, and biological samples can be analyzed for those radionuclides without matrix interferences in the quality of radioelement purification and in the radiochemical yield. The use of isotopic tracers (232U, 229Th, 224Ra, 209Po, and stable lead carrier) added to the sample in the beginning of the chemical procedure, enables an accurate control of the radiochemical yield for each radioelement. The ion extraction procedure, applied after either complete dissolution of the solid sample with mineral acids or co-precipitation of dissolved radionuclide with MnO2 for aqueous samples, includes the use of commercially available pre-packed columns from Eichrom® and ion exchange columns packed with Bio-Rad resins, in altogether three chromatography columns. All radioactive elements but one are purified and electroplated on stainless steel discs. Polonium is spontaneously plated on a silver disc. The discs are measured using high resolution silicon surface barrier detectors. 210Pb, a beta emitter, can be measured either through the beta emission of 210Bi, or stored for a few months and determined by alpha spectrometry through the in-growth of 210Po. This sequential extraction chromatography technique was tested and validated with the analysis of certified reference materials from the IAEA. Reproducibility was tested through repeated analysis of the same homogeneous material (water sample).

  11. Sampling and Analysis for Assessment of Body Burdens

    International Nuclear Information System (INIS)

    Harley, J.H.

    1964-01-01

    A review of sampling criteria and techniques and of sample processing methods for indirect assessment of body burdens is presented. The text is limited to the more recent developments in the field of bioassay and to the nuclides which cannot be readily determined in the body directly. A selected bibliography is included. The planning of a bioassay programme should emphasize the detection of high or unusual exposures and the concentrated study of these cases when detected. This procedure gives the maximum amount of data for the dosimetry of individuals at risk and also adds to our scientific background for an understanding of internal emitters. Only a minimum of effort should be spent on sampling individuals having had negligible exposure. The chemical separation procedures required for bioassay also fall into two categories. The first is the rapid method, possibly of low accuracy, used for detection. The second is the more accurate method required for study of the individual after detection of the exposure. Excretion, whether exponential or a power function, drops off rapidly. It is necessary to locate the exposure in time before any evaluation can be made, even before deciding if the exposure is significant. One approach is frequent sampling and analysis by a quick screening technique. More commonly, samples are collected at longer intervals and an arbitrary level of re-sampling is set to assist in the detection of real exposures. It is probable that too much bioassay effort has gone into measurements on individuals at low risk and not enough on those at higher risk. The development of bioassay procedures for overcoming this problem has begun, and this paper emphasizes this facet of sampling and sample processing. (author) [fr

  12. Pre-exposure to food temptation reduces subsequent consumption: A test of the procedure with a South-African sample.

    Science.gov (United States)

    Duh, Helen Inseng; Grubliauskiene, Aiste; Dewitte, Siegfried

    2016-01-01

    It has been suggested that the consumption of unhealthy Westernized diet in a context of poverty and resultant food insecurity may have contributed to South-Africa's status of the third fattest country in the World. Considering that a number of South-Africans are reported to have experienced, or are still experiencing food insecurity, procedures which have been shown to reduce the consumption of unhealthy food in higher income countries may be ineffective in South-Africa. We thus tested the robustness of the so called pre-exposure procedure in South-Africa. We also tested the moderating role of childhood poverty in the pre-exposure procedure. With the pre-exposure procedure, a respondent is exposed to a tempting unhealthy food (e.g. candy) in a context that is designed such that eating the food interferes with a task goal. The typical result is that this procedure spills over and reduces consumption of similar tempting food later on. An experimental study conducted in a South-African laboratory showed that the pre-exposure effect is robust even with a sample, where food insecurity prevails. Childhood poverty did not moderate the effect. This study proves that behavioral procedures aimed at reducing the consumption of unhealthy food would be valuable in less rich non-Western countries. Further testing of the robustness of the pre-exposure effect is however recommended in other poorer food insecure countries. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Development of procedure for measurement of Pb isotope ratios in seawater by application of seaFAST sample pre-treatment system and Sector Field Inductively Coupled Plasma Mass Spectrometry

    Science.gov (United States)

    Vassileva, Emilia; Wysocka, Irena

    2016-12-01

    Anthropogenic Pb in the oceans, derived from high-temperature industrial processes, fuel combustion and incineration can have an isotopic signature distinct from naturally occurring Pb, supplied by rock weathering. To identify the different pollution sources accurately and to quantify their relative contributions, Pb isotope ratios are widely used. Due to the high salt content (approximately 3.5% of total dissolved solids) and very low levels of Pb (typically from 1 to 100 ng L- 1) in seawater the determination of Pb isotope ratios requires preliminary matrix separation and analyte preconcentration. An analytical protocol for the measurements of Pb isotope ratios in seawater combining seaFAST sample pre-treatment system and Sector Field Inductively Coupled Plasma Mass Spectrometry (SF ICP-MS) was developed. The application of seaFAST system was advantageous, because of its completely closed working cycle and small volumes of chemicals introduced in pre-treatment step, resulting in very low detection limits and procedural blanks. The preconcentration/matrix separation step was also of crucial importance for minimizing the isobaric and matrix interferences, coming from the seawater. In order to differentiate between anthropogenic and natural Pb sources, particular attention was paid to the determination of 204Pb isotope because of its implication in some geological interpretations. The validation of the analytical procedure was effectuated according to the recommendations of the ISO/IEC 17025 standard. The method was validated by processing the common Pb isotope reference material NIST SRM 981. All major sources of uncertainty were identified and propagated together following the ISO/GUM guidelines. The estimation of the total uncertainty associated to each measurement result was fundamental tool for sorting the main sources of possible biases. The developed analytical procedure was applied to the coastal and open seawater samples, collected in different regions of

  14. 40 CFR 89.413 - Raw sampling procedures.

    Science.gov (United States)

    2010-07-01

    ... of the exhaust pipe—whichever is the larger—upstream of the exit of the exhaust gas system. (b) In..., such as in a “Vee” engine configuration, it is permissible to: (1) Sample after all exhaust pipes have been connected together into a single exhaust pipe. (2) For each mode, sample from each exhaust pipe...

  15. Influence of volume of sample processed on detection of Chlamydia trachomatis in urogenital samples by PCR

    NARCIS (Netherlands)

    Goessens, W H; Kluytmans, J A; den Toom, N; van Rijsoort-Vos, T H; Niesters, B G; Stolz, E; Verbrugh, H A; Quint, W G

    In the present study, it was demonstrated that the sensitivity of the PCR for the detection of Chlamydia trachomatis is influenced by the volume of the clinical sample which is processed in the PCR. An adequate sensitivity for PCR was established by processing at least 4%, i.e., 80 microliters, of

  16. A radiochemical procedure for a low-level measurement of ''241 Am in environmental samples using a supported functional organo phosphorus extractant

    International Nuclear Information System (INIS)

    Gasco, C.; Anton, M.A.; Alvarez, A.; Navarro, N.; Salvador, S.

    1994-01-01

    The transuranides analysis in environmental samples is carried out by CIEMAT using standardized methods based on sequential separation with ionic-exchange resins. The americium fraction is purified through a two-layer ion exchange column and lately in an anion-exchange column in nitric acid methanol medium. The technique is time-consuming and the results are not completely satisfactory (low recovery and loss of alpha-resolution) for some samples. The chemical compound CMPO (octyl(phenyl).N,N-diisobutyl carbomoylmethyiphosphine oxide) dissolved in TPB (tributyl phosphate) and supported on an inert substrate has been tested directly for ''241 Am analysis by a large number of laboratories. A new method that combines both procedures has been developed. The details of the improved procedure are described in this paper. The advantages of its application to environmental samples (urine, faeces and sediments) are discussed. The utilization of standard, with americium certified concentrations confirms the reliability of our measurements

  17. Comparison of the radiochemical separation procedures od plutonium applied for its determination in the environmental samples using alpha spectrometry

    International Nuclear Information System (INIS)

    Komosa, A.; Michalik, S.

    2006-01-01

    Alpha spectrometry of the plutonium isotopes can be performed only after the perfect plutonium separation from other components of the matrix. So, till now numerous procedures have been elaborated and tested. The communication presents comparison of the plutonium content determination in soil, bones, eggshells and in the reference materials obtained by alpha spectrometry combined with two different separation procedures. The samples were mineralized in the concentrated HCl or HF prior to plutonium electrodeposition or coprecipitation with NdF 3 . Some other details were also tested in various variants. Quality of the spectra is discussed in terms of all these pre-treatment methods

  18. Sample Size for Tablet Compression and Capsule Filling Events During Process Validation.

    Science.gov (United States)

    Charoo, Naseem Ahmad; Durivage, Mark; Rahman, Ziyaur; Ayad, Mohamad Haitham

    2017-12-01

    During solid dosage form manufacturing, the uniformity of dosage units (UDU) is ensured by testing samples at 2 stages, that is, blend stage and tablet compression or capsule/powder filling stage. The aim of this work is to propose a sample size selection approach based on quality risk management principles for process performance qualification (PPQ) and continued process verification (CPV) stages by linking UDU to potential formulation and process risk factors. Bayes success run theorem appeared to be the most appropriate approach among various methods considered in this work for computing sample size for PPQ. The sample sizes for high-risk (reliability level of 99%), medium-risk (reliability level of 95%), and low-risk factors (reliability level of 90%) were estimated to be 299, 59, and 29, respectively. Risk-based assignment of reliability levels was supported by the fact that at low defect rate, the confidence to detect out-of-specification units would decrease which must be supplemented with an increase in sample size to enhance the confidence in estimation. Based on level of knowledge acquired during PPQ and the level of knowledge further required to comprehend process, sample size for CPV was calculated using Bayesian statistics to accomplish reduced sampling design for CPV. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  19. A novel sample preparation procedure for effect-directed analysis of micro-contaminants of emerging concern in surface waters.

    Science.gov (United States)

    Osorio, Victoria; Schriks, Merijn; Vughs, Dennis; de Voogt, Pim; Kolkman, Annemieke

    2018-08-15

    A novel sample preparation procedure relying on Solid Phase Extraction (SPE) combining different sorbent materials on a sequential-based cartridge was optimized and validated for the enrichment of 117 widely diverse contaminants of emerging concern (CECs) from surface waters (SW) and further combined chemical and biological analysis on subsequent extracts. A liquid chromatography coupled to high resolution tandem mass spectrometry LC-(HR)MS/MS protocol was optimized and validated for the quantitative analysis of organic CECs in SW extracts. A battery of in vitro CALUX bioassays for the assessment of endocrine, metabolic and genotoxic interference and oxidative stress were performed on the same SW extracts. Satisfactory recoveries ([70-130]%) and precision ( 0.99) over three orders of magnitude. Instrumental limits of detection and method limits of quantification were of [1-96] pg injected and [0.1-58] ng/L, respectively; while corresponding intra-day and inter-day precision did not exceed 11% and 20%. The developed procedure was successfully applied for the combined chemical and toxicological assessment of SW intended for drinking water supply. Levels of compounds varied from < 10 ng/L to < 500 ng/L. Endocrine (i.e. estrogenic and anti-androgenic) and metabolic interference responses were observed. Given the demonstrated reliability of the validated sample preparation method, the authors propose its integration in an effect-directed analysis procedure for a proper evaluation of SW quality and hazard assessment of CECs. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Application of fast procedures for the real-time processing of multi-parameter events in the γ-spectroscopy

    International Nuclear Information System (INIS)

    Hanewinkel, H.

    1984-01-01

    The construction of a new structurated data acquisition system at the Cologne tandem accelerator should contribute to the further development of the experimental methods in nuclear physics. For this fast procedures for the real-time processing and on-line data reduction of multi-parameter events were development and applied. These procedures allowed in connection with the whole analyzer system an effective processing of the occurring many-parametric data. By this work an important condition for the experimental application of the high-resolution γγ anti-Compton coincidence spectrometer OSIRIS, which is constructed in an collaboration with goups in Berlin, Bonn, and Julich, was created at the Cologne accelerator. The ensued analyzer system offers however also to all other users an extension of their experimental possibilities. The requirements and the structure of the analyzer system as well as the procedures developed and applied for this are described and compared with other procedures proposed in literature. (orig./HSI) [de

  1. Field sampling, preparation procedure and plutonium analyses of large freshwater samples

    International Nuclear Information System (INIS)

    Straelberg, E.; Bjerk, T.O.; Oestmo, K.; Brittain, J.E.

    2002-01-01

    This work is part of an investigation of the mobility of plutonium in freshwater systems containing humic substances. A well-defined bog-stream system located in the catchment area of a subalpine lake, Oevre Heimdalsvatn, Norway, is being studied. During the summer of 1999, six water samples were collected from the tributary stream Lektorbekken and the lake itself. However, the analyses showed that the plutonium concentration was below the detection limit in all the samples. Therefore renewed sampling at the same sites was carried out in August 2000. The results so far are in agreement with previous analyses from the Heimdalen area. However, 100 times higher concentrations are found in the lowlands in the eastern part of Norway. The reason for this is not understood, but may be caused by differences in the concentrations of humic substances and/or the fact that the mountain areas are covered with snow for a longer period of time every year. (LN)

  2. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF URINE SAMPLES FOR METAL, PESTICIDE, AND CREATININE ANALYSIS (F10)

    Science.gov (United States)

    The purpose of this SOP is to describe the procedures for collection, storage, and shipment of urine samples for metal, pesticides, and creatinine analysis. Samples were collected on Days 2 and 8 of each Cycle. The Day 2 sample was analyzed for metals and creatinine. The Day 8...

  3. Development of a radiochemical neutron activation analysis procedure for determination of rhenium in biological and environmental samples at ultratrace level

    International Nuclear Information System (INIS)

    Kucera, J.; Lucanikova, M.; Czech Technical Univ., Prague

    2006-01-01

    Radiochemical neutron activation procedures using liquid-liquid extraction with tetraphenylarsonium chloride in chloroform from 1M HCl and solid extraction with ALIQUAT 336 incorporated in a polyacrylonitrile binding matrix from 0.1M HCl were developed for accurate determination of rhenium in biological and environmental samples at the sub-ng x g -1 level. Concentrations of Re in the range of 0.1 to 2.4 ng x g -1 were determined in several botanical reference materials (RM), while in a RM of road dust a value of ∼ 10 ng x g -1 was found. Significantly elevated values of Re, up to 90 ng x g -1 were found in seaweed (brown algae). Results for Re in the brown algae Fucus vesiculosus in which elevated 99 Tc values had previously been determined suggested possible competition between Re and Tc in the accumulation process. (author)

  4. Detection of toxigenic vibrio cholera from environmental water samples by an enrichment broth cultivation-pit-stop semi-nested PCR procedure

    CSIR Research Space (South Africa)

    Theron, J

    2000-09-01

    Full Text Available V. cholerae. The PCR procedure coupled with an enrichment culture detected as few as four V. cholerae organisms in pure culture. Treated sewage, surface, ground and drinking water samples were seeded with V, cholerae and following enrichment, a...

  5. Nonuniform sampling and non-Fourier signal processing methods in multidimensional NMR.

    Science.gov (United States)

    Mobli, Mehdi; Hoch, Jeffrey C

    2014-11-01

    Beginning with the introduction of Fourier Transform NMR by Ernst and Anderson in 1966, time domain measurement of the impulse response (the free induction decay, FID) consisted of sampling the signal at a series of discrete intervals. For compatibility with the discrete Fourier transform (DFT), the intervals are kept uniform, and the Nyquist theorem dictates the largest value of the interval sufficient to avoid aliasing. With the proposal by Jeener of parametric sampling along an indirect time dimension, extension to multidimensional experiments employed the same sampling techniques used in one dimension, similarly subject to the Nyquist condition and suitable for processing via the discrete Fourier transform. The challenges of obtaining high-resolution spectral estimates from short data records using the DFT were already well understood, however. Despite techniques such as linear prediction extrapolation, the achievable resolution in the indirect dimensions is limited by practical constraints on measuring time. The advent of non-Fourier methods of spectrum analysis capable of processing nonuniformly sampled data has led to an explosion in the development of novel sampling strategies that avoid the limits on resolution and measurement time imposed by uniform sampling. The first part of this review discusses the many approaches to data sampling in multidimensional NMR, the second part highlights commonly used methods for signal processing of such data, and the review concludes with a discussion of other approaches to speeding up data acquisition in NMR. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Evaluation and optimization of DNA extraction and purification procedures for soil and sediment samples.

    Science.gov (United States)

    Miller, D N; Bryant, J E; Madsen, E L; Ghiorse, W C

    1999-11-01

    We compared and statistically evaluated the effectiveness of nine DNA extraction procedures by using frozen and dried samples of two silt loam soils and a silt loam wetland sediment with different organic matter contents. The effects of different chemical extractants (sodium dodecyl sulfate [SDS], chloroform, phenol, Chelex 100, and guanadinium isothiocyanate), different physical disruption methods (bead mill homogenization and freeze-thaw lysis), and lysozyme digestion were evaluated based on the yield and molecular size of the recovered DNA. Pairwise comparisons of the nine extraction procedures revealed that bead mill homogenization with SDS combined with either chloroform or phenol optimized both the amount of DNA extracted and the molecular size of the DNA (maximum size, 16 to 20 kb). Neither lysozyme digestion before SDS treatment nor guanidine isothiocyanate treatment nor addition of Chelex 100 resin improved the DNA yields. Bead mill homogenization in a lysis mixture containing chloroform, SDS, NaCl, and phosphate-Tris buffer (pH 8) was found to be the best physical lysis technique when DNA yield and cell lysis efficiency were used as criteria. The bead mill homogenization conditions were also optimized for speed and duration with two different homogenizers. Recovery of high-molecular-weight DNA was greatest when we used lower speeds and shorter times (30 to 120 s). We evaluated four different DNA purification methods (silica-based DNA binding, agarose gel electrophoresis, ammonium acetate precipitation, and Sephadex G-200 gel filtration) for DNA recovery and removal of PCR inhibitors from crude extracts. Sephadex G-200 spin column purification was found to be the best method for removing PCR-inhibiting substances while minimizing DNA loss during purification. Our results indicate that for these types of samples, optimum DNA recovery requires brief, low-speed bead mill homogenization in the presence of a phosphate-buffered SDS-chloroform mixture, followed

  7. Centrifugation: an important pre-analytic procedure that influences plasma microRNA quantification during blood processing.

    Science.gov (United States)

    Zheng, Xiao-Hui; Cui, Cui; Zhou, Xin-Xi; Zeng, Yi-Xin; Jia, Wei-Hua

    2013-12-01

    Circulating microRNAs are robustly present in plasma or serum and have become a research focus as biomarkers for tumor diagnosis and prognosis. Centrifugation is a necessary procedure for obtaining high-quality blood supernatant. Herein, we investigated one-step and two-step centrifugations, two centrifugal methods routinely used in microRNA study, to explore their effects on plasma microRNA quantification. The microRNAs obtained from one-step and two-step centrifugations were quantified by microarray and TaqMan-based real-time quantitative polymerase chain reaction (Q-PCR). Dynamic light scattering was performed to explore the difference underlying the two centrifugal methods. The results from the microarray containing 1,347 microRNAs showed that the signal detection rate was greatly decreased in the plasma sample prepared by two-step centrifugation. More importantly, the microRNAs missing in this plasma sample could be recovered and detected in the precipitate generated from the second centrifugation. Consistent with the results from microarray, a marked decrease of three representative microRNAs in two-step centrifugal plasma was validated by Q-PCR. According to the size distribution of all nanoparticles in plasma, there were fewer nanoparticles with size >1,000 nm in two-step centrifugal plasma. Our experiments directly demonstrated that different centrifugation methods produced distinct quantities of plasma microRNAs. Thus, exosomes or protein complexes containing microRNAs may be involved in large nanoparticle formation and may be precipitated after two-step centrifugation. Our results remind us that sample processing methods should be first considered in conducting research.

  8. 40 CFR 63.496 - Back-end process provisions-procedures to determine compliance using control or recovery devices.

    Science.gov (United States)

    2010-07-01

    ... boiler or process heater. (iii) The control efficiency of the boiler or process heater shall be calculated using Equation 29. ER05SE96.027 where: R=Control efficiency of boiler or process heater, percent..., the control efficiency of the boiler or process heater shall be determined using the procedures in...

  9. Pollutant Assessments Group procedures manual: Volume 2, Technical procedures

    Energy Technology Data Exchange (ETDEWEB)

    1992-03-01

    This is volume 2 of the manuals that describes the technical procedures currently in use by the Pollution Assessments Group. This manual incorporates new developments in hazardous waste assessment technology and administrative policy. Descriptions of the equipment, procedures and operations of such things as radiation detection, soil sampling, radionuclide monitoring, and equipment decontamination are included in this manual. (MB)

  10. Determination of calcium, potassium, manganese, iron, copper and zinc levels in representative samples of two onion cultivars using total reflection X-ray fluorescence and ultrasound extraction procedure

    International Nuclear Information System (INIS)

    Alvarez, J.; Marco, L.M.; Arroyo, J.; Greaves, E.D.; Rivas, R.

    2003-01-01

    The chemical characterization of onion cultivar samples is an important tool for the enhancement of their productivity due to the fact that chemical composition is closed related to the quality of the products. A new sample preparation procedure for elemental characterization is proposed, involving the acid extraction of the analytes from crude samples by means of an ultrasonic bath, avoiding the required digestion of samples in vegetable tissue analysis. The technique of total reflection X-ray fluorescence (TXRF) was successfully applied for the simultaneous determination of the elements Ca, K, Mn, Fe, Cu and Zn. The procedure was compared with the wet ashing and dry ashing procedures for all the elements using multivariate analysis and the Scheffe test. The technique of flame atomic absorption spectrometry (FAAS) was employed for comparison purposes and accuracy evaluation of the proposed analysis method. A good agreement between the two techniques was found when using the dry ashing and ultrasound leaching procedures. The levels of each element found for representative samples of two onion cultivars (Yellow Granex PRR 502 and 438 Granex) were also compared by the same method. Levels of K, Mn and Zn were significantly higher in the 438 Granex cultivar, while levels of Ca, Fe and Cu were significantly higher in the Yellow Granex PRR 502 cultivar

  11. Automation of sample processing for ICP-MS determination of 90Sr radionuclide at ppq level for nuclear technology and environmental purposes.

    Science.gov (United States)

    Kołacińska, Kamila; Chajduk, Ewelina; Dudek, Jakub; Samczyński, Zbigniew; Łokas, Edyta; Bojanowska-Czajka, Anna; Trojanowicz, Marek

    2017-07-01

    90 Sr is a widely determined radionuclide for environmental purposes, nuclear waste control, and can be also monitored in coolants in nuclear reactor plants. In the developed method, the ICP-MS detection was employed together with sample processing in sequential injection analysis (SIA) setup, equipped with a lab-on-valve with mechanized renewal of sorbent bed for solid-phase extraction. The optimized conditions of determination included preconcentration of 90 Sr on cation-exchange column and removal of different type of interferences using extraction Sr-resin. The limit of detection of the developed procedure depends essentially on the configuration of the employed ICP-MS spectrometer and on the available volume of the sample to be analyzed. For 1L initial sample volume, the method detection limit (MDL) value was evaluated as 2.9ppq (14.5BqL -1 ). The developed method was applied to analyze spiked river water samples, water reference materials, and also simulated and real samples of the nuclear reactor coolant. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. FMRI evidence for the involvement of the procedural memory system in morphological processing of a second language.

    Directory of Open Access Journals (Sweden)

    Christos Pliatsikas

    Full Text Available Behavioural evidence suggests that English regular past tense forms are automatically decomposed into their stem and affix (played  = play+ed based on an implicit linguistic rule, which does not apply to the idiosyncratically formed irregular forms (kept. Additionally, regular, but not irregular inflections, are thought to be processed through the procedural memory system (left inferior frontal gyrus, basal ganglia, cerebellum. It has been suggested that this distinction does not to apply to second language (L2 learners of English; however, this has not been tested at the brain level. This fMRI study used a masked-priming task with regular and irregular prime-target pairs (played-play/kept-keep to investigate morphological processing in native and highly proficient late L2 English speakers. No between-groups differences were revealed. Compared to irregular pairs, regular pairs activated the pars opercularis, bilateral caudate nucleus and the right cerebellum, which are part of the procedural memory network and have been connected with the processing of morphologically complex forms. Our study is the first to provide evidence for native-like involvement of the procedural memory system in processing of regular past tense by late L2 learners of English.

  13. Optimisation (sampling strategies and analytical procedures) for site specific environment monitoring at the areas of uranium production legacy sites in Ukraine - 59045

    International Nuclear Information System (INIS)

    Voitsekhovych, Oleg V.; Lavrova, Tatiana V.; Kostezh, Alexander B.

    2012-01-01

    There are many sites in the world, where Environment are still under influence of the contamination related to the Uranium production carried out in past. Author's experience shows that lack of site characterization data, incomplete or unreliable environment monitoring studies can significantly limit quality of Safety Assessment procedures and Priority actions analyses needed for Remediation Planning. During recent decades the analytical laboratories of the many enterprises, currently being responsible for establishing the site specific environment monitoring program have been significantly improved their technical sampling and analytical capacities. However, lack of experience in the optimal site specific sampling strategy planning and also not enough experience in application of the required analytical techniques, such as modern alpha-beta radiometers, gamma and alpha spectrometry and liquid-scintillation analytical methods application for determination of U-Th series radionuclides in the environment, does not allow to these laboratories to develop and conduct efficiently the monitoring programs as a basis for further Safety Assessment in decision making procedures. This paper gives some conclusions, which were gained from the experience establishing monitoring programs in Ukraine and also propose some practical steps on optimization in sampling strategy planning and analytical procedures to be applied for the area required Safety assessment and justification for its potential remediation and safe management. (authors)

  14. Evaluation of standard methods for collecting and processing fuel moisture samples

    Science.gov (United States)

    Sally M. Haase; José Sánchez; David R. Weise

    2016-01-01

    A variety of techniques for collecting and processing samples to determine moisture content of wildland fuels in support of fire management activities were evaluated. The effects of using a chainsaw or handsaw to collect samples of largediameter wood, containers for storing and transporting collected samples, and quick-response ovens for estimating moisture content...

  15. High peak power processing up to 100 MV/M on various metallic samples

    International Nuclear Information System (INIS)

    Luong, M.; Bonin, B.; Safa, H.

    1996-01-01

    The high peak power processing (HPPP) is a well established way to reduce electronic field emission from radiofrequency (RF) metallic surfaces. The processing occurs because of some kind of instability destroys the emitter, but the basic physical mechanism at work has not yet been clearly identified. RF processing experiments on samples of restricted area, are described with well localized artificial emitting sites (protrusions from scratches on the sample surface). In order to disentangle the role of thermal and mechanical effects, in the processing, the samples were made from metals with different melting temperatures and tensile strengths. (author)

  16. High peak power processing up to 100 MV/m on various metallic samples

    International Nuclear Information System (INIS)

    Luong, M.; Bonin, B.; Safa, H.; Le Goff, A.

    1996-01-01

    The high peak power processing (HPPP) is a well established way to reduce electronic field emission from radiofrequency (RF) metallic surfaces. The processing occurs because of some kind of instability destroys the emitter, but the basic physical mechanism at work has not yet been clearly identified. The present study describes RF processing experiments on samples of restricted area, with well localized artificial emitting sites (protrusions from scratches on the sample surface). In order to disentangle the role of thermal and mechanical effects in the processing, the samples were made from metals with different melting temperatures and tensile strengths. (author)

  17. Rare behavior of growth processes via umbrella sampling of trajectories

    Science.gov (United States)

    Klymko, Katherine; Geissler, Phillip L.; Garrahan, Juan P.; Whitelam, Stephen

    2018-03-01

    We compute probability distributions of trajectory observables for reversible and irreversible growth processes. These results reveal a correspondence between reversible and irreversible processes, at particular points in parameter space, in terms of their typical and atypical trajectories. Thus key features of growth processes can be insensitive to the precise form of the rate constants used to generate them, recalling the insensitivity to microscopic details of certain equilibrium behavior. We obtained these results using a sampling method, inspired by the "s -ensemble" large-deviation formalism, that amounts to umbrella sampling in trajectory space. The method is a simple variant of existing approaches, and applies to ensembles of trajectories controlled by the total number of events. It can be used to determine large-deviation rate functions for trajectory observables in or out of equilibrium.

  18. 75 FR 60171 - Proposed Information Collection (Credit Underwriting Standards and Procedures for Processing VA...

    Science.gov (United States)

    2010-09-29

    ... DEPARTMENT OF VETERANS AFFAIRS [OMB Control No. 2900-0521] Proposed Information Collection (Credit Underwriting Standards and Procedures for Processing VA Guaranteed Loans) Activity: Comment Request AGENCY... comment on the proposed collection of certain information by the agency. Under the Paperwork Reduction Act...

  19. 78 FR 60379 - Proposed Information Collection (Credit Underwriting Standards and Procedures for Processing VA...

    Science.gov (United States)

    2013-10-01

    ... DEPARTMENT OF VETERANS AFFAIRS [OMB Control No. 2900-0521] Proposed Information Collection (Credit Underwriting Standards and Procedures for Processing VA Guaranteed Loans) Activity: Comment Request AGENCY... comment on the proposed collection of certain information by the agency. Under the Paperwork Reduction Act...

  20. Possible Overestimation of Surface Disinfection Efficiency by Assessment Methods Based on Liquid Sampling Procedures as Demonstrated by In Situ Quantification of Spore Viability ▿

    Science.gov (United States)

    Grand, I.; Bellon-Fontaine, M.-N.; Herry, J.-M.; Hilaire, D.; Moriconi, F.-X.; Naïtali, M.

    2011-01-01

    The standard test methods used to assess the efficiency of a disinfectant applied to surfaces are often based on counting the microbial survivors sampled in a liquid, but total cell removal from surfaces is seldom achieved. One might therefore wonder whether evaluations of microbial survivors in liquid-sampled cells are representative of the levels of survivors in whole populations. The present study was thus designed to determine the “damaged/undamaged” status induced by a peracetic acid disinfection for Bacillus atrophaeus spores deposited on glass coupons directly on this substrate and to compare it to the status of spores collected in liquid by a sampling procedure. The method utilized to assess the viability of both surface-associated and liquid-sampled spores included fluorescence labeling with a combination of Syto 61 and Chemchrome V6 dyes and quantifications by analyzing the images acquired by confocal laser scanning microscopy. The principal result of the study was that the viability of spores sampled in the liquid was found to be poorer than that of surface-associated spores. For example, after 2 min of peracetic acid disinfection, less than 17% ± 5% of viable cells were detected among liquid-sampled cells compared to 79% ± 5% or 47% ± 4%, respectively, when the viability was evaluated on the surface after or without the sampling procedure. Moreover, assessments of the survivors collected in the liquid phase, evaluated using the microscopic method and standard plate counts, were well correlated. Evaluations based on the determination of survivors among the liquid-sampled cells can thus overestimate the efficiency of surface disinfection procedures. PMID:21742922

  1. Static sampling of dynamic processes - a paradox?

    Science.gov (United States)

    Mälicke, Mirko; Neuper, Malte; Jackisch, Conrad; Hassler, Sibylle; Zehe, Erwin

    2017-04-01

    Environmental systems monitoring aims at its core at the detection of spatio-temporal patterns of processes and system states, which is a pre-requisite for understanding and explaining their baffling heterogeneity. Most observation networks rely on distributed point sampling of states and fluxes of interest, which is combined with proxy-variables from either remote sensing or near surface geophysics. The cardinal question on the appropriate experimental design of such a monitoring network has up to now been answered in many different ways. Suggested approaches range from sampling in a dense regular grid using for the so-called green machine, transects along typical catenas, clustering of several observations sensors in presumed functional units or HRUs, arrangements of those cluster along presumed lateral flow paths to last not least a nested, randomized stratified arrangement of sensors or samples. Common to all these approaches is that they provide a rather static spatial sampling, while state variables and their spatial covariance structure dynamically change in time. It is hence of key interest how much of our still incomplete understanding stems from inappropriate sampling and how much needs to be attributed to an inappropriate analysis of spatial data sets. We suggest that it is much more promising to analyze the spatial variability of processes, for instance changes in soil moisture values, than to investigate the spatial variability of soil moisture states themselves. This is because wetting of the soil, reflected in a soil moisture increase, is causes by a totally different meteorological driver - rainfall - than drying of the soil. We hence propose that the rising and the falling limbs of soil moisture time series belong essentially to different ensembles, as they are influenced by different drivers. Positive and negative temporal changes in soil moisture need, hence, to be analyzed separately. We test this idea using the CAOS data set as a benchmark

  2. Procedure, algorithm and criterions of determination of a burnup of a irradiated nuclear fuel in process of overloading

    International Nuclear Information System (INIS)

    Bilej, D.V.; Fridman, N.A.; Maslov, O.V.; Maksimov, M.V.

    2001-01-01

    The procedure, algorithm and criterions of determination of a burnup of the irradiated nuclear fuel in process of overloading are described. The feature of the procedure, algorithm and criterions consists in the account of initial enrichment and cooling time nuclear fuel after irradiation

  3. Develpoment of a procedure for the determination of chromium in samples of urine and serum by neutron activation analysis

    International Nuclear Information System (INIS)

    Buettner, I.; Hamm, V.; Knoechel, A.; Sen Gupta, R.

    1993-01-01

    Since the mid-fifties the possibility of a causal relationship between deficient chromium and insulin metabolism and the manifestation of certain varieties of diabetes mellitus has been presumed. The determination of the chromium status under pathophysiological conditions may be helpful for the study of this problem. For these purposes an analytical procedure as reference system was developed which allows the determination of chromium in biological matrices down to the concentration of 0.33 ng/ml. It is based on NAA and is used in the framework of a commonly used procedure based on GF-AAS. For its application blood and urine samples are freeze-dried and irradiated. After wet digestion with HNO 3 in a microwave combustion system chromium is separated for measurement from the matrix nuclides with the help of the ion-exchanger Cellex-P. THe individual steps of the procedure were evaluated by means of tracer experiments. (orig.)

  4. Develpoment of a procedure for the determination of chromium in samples of urine and serum by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Buettner, I [Hamburg Univ. (Germany). Inst. for Inorganic and Applied Chemistry; Hamm, V [Hamburg Univ. (Germany). Inst. for Inorganic and Applied Chemistry; Knoechel, A [Hamburg Univ. (Germany). Inst. for Inorganic and Applied Chemistry; Sen Gupta, R [Hamburg Univ. (Germany). Inst. for Inorganic and Applied Chemistry

    1993-06-01

    Since the mid-fifties the possibility of a causal relationship between deficient chromium and insulin metabolism and the manifestation of certain varieties of diabetes mellitus has been presumed. The determination of the chromium status under pathophysiological conditions may be helpful for the study of this problem. For these purposes an analytical procedure as reference system was developed which allows the determination of chromium in biological matrices down to the concentration of 0.33 ng/ml. It is based on NAA and is used in the framework of a commonly used procedure based on GF-AAS. For its application blood and urine samples are freeze-dried and irradiated. After wet digestion with HNO[sub 3] in a microwave combustion system chromium is separated for measurement from the matrix nuclides with the help of the ion-exchanger Cellex-P. THe individual steps of the procedure were evaluated by means of tracer experiments. (orig.)

  5. 75 FR 76082 - Agency Information Collection (Credit Underwriting Standards and Procedures for Processing VA...

    Science.gov (United States)

    2010-12-07

    ... DEPARTMENT OF VETERANS AFFAIRS [OMB Control No. 2900-0521] Agency Information Collection (Credit Underwriting Standards and Procedures for Processing VA Guaranteed Loans) Activity Under OMB Review AGENCY... information abstracted below to the Office of Management and Budget (OMB) for review and comment. The PRA...

  6. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Science.gov (United States)

    2010-07-01

    ... ADMINISTRATION AIR FORCE FREEDOM OF INFORMATION ACT PROGRAM § 806.27 Samples of Air Force FOIA processing... determination within 20 workdays, we have instituted multitrack processing of requests. Based on the information... source; responsive records were part of the Air Force's decision-making process, and the prerelease...

  7. Processing scarce biological samples for light and transmission electron microscopy

    Directory of Open Access Journals (Sweden)

    P Taupin

    2008-06-01

    Full Text Available Light microscopy (LM and transmission electron microscopy (TEM aim at understanding the relationship structure-function. With advances in biology, isolation and purification of scarce populations of cells or subcellular structures may not lead to enough biological material, for processing for LM and TEM. A protocol for preparation of scarce biological samples is presented. It is based on pre-embedding the biological samples, suspensions or pellets, in bovine serum albumin (BSA and bis-acrylamide (BA, cross-linked and polymerized. This preparation provides a simple and reproducible technique to process biological materials, present in limited quantities that can not be amplified, for light and transmission electron microscopy.

  8. Finite element simulation of the T-shaped ECAP processing of round samples

    Science.gov (United States)

    Shaban Ghazani, Mehdi; Fardi-Ilkhchy, Ali; Binesh, Behzad

    2018-05-01

    Grain refinement is the only mechanism that increases the yield strength and toughness of the materials simultaneously. Severe plastic deformation is one of the promising methods to refine the microstructure of materials. Among different severe plastic deformation processes, the T-shaped equal channel angular pressing (T-ECAP) is a relatively new technique. In the present study, finite element analysis was conducted to evaluate the deformation behavior of metals during T-ECAP process. The study was focused mainly on flow characteristics, plastic strain distribution and its homogeneity, damage development, and pressing force which are among the most important factors governing the sound and successful processing of nanostructured materials by severe plastic deformation techniques. The results showed that plastic strain is localized in the bottom side of sample and uniform deformation cannot be possible using T-ECAP processing. Friction coefficient between sample and die channel wall has a little effect on strain distributions in mirror plane and transverse plane of deformed sample. Also, damage analysis showed that superficial cracks may be initiated from bottom side of sample and their propagation will be limited due to the compressive state of stress. It was demonstrated that the V shaped deformation zone are existed in T-ECAP process and the pressing load needed for execution of deformation process is increased with friction.

  9. Optimization of microwave assisted digestion procedure for the determination of zinc, copper and nickel in tea samples employing flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Soylak, Mustafa; Tuzen, Mustafa; Souza, Anderson Santos; Korn, Maria das Gracas Andrade; Ferreira, Sergio Luis Costa

    2007-01-01

    The present paper describes the development of a microwave assisted digestion procedure for the determination of zinc, copper and nickel in tea samples employing flame atomic absorption spectrometry (FAAS). The optimization step was performed using a full factorial design (2 3 ) involving the factors: composition of the acid mixture (CMA), microwave power (MP) and radiation time (RT). The experiments of this factorial were carried out using a certified reference material of tea GBW 07605 furnished by National Research Centre for Certified Reference Materials, China, being the metal recoveries considered as response. The relative standard deviations of the method were found below 8% for the three elements. The procedure proposed was used for the determination of copper, zinc and nickel in several samples of tea from Turkey. For 10 tea samples analyzed, the concentration achieved for copper, zinc and nickel varied at 6.4-13.1, 7.0-16.5 and 3.1-5.7 (μg g -1 ), respectively

  10. Optimization of a Pre-MEKC Separation SPE Procedure for Steroid Molecules in Human Urine Samples

    Directory of Open Access Journals (Sweden)

    Ilona Olędzka

    2013-11-01

    Full Text Available Many steroid hormones can be considered as potential biomarkers and their determination in body fluids can create opportunities for the rapid diagnosis of many diseases and disorders of the human body. Most existing methods for the determination of steroids are usually time- and labor-consuming and quite costly. Therefore, the aim of analytical laboratories is to develop a new, relatively low-cost and rapid implementation methodology for their determination in biological samples. Due to the fact that there is little literature data on concentrations of steroid hormones in urine samples, we have made attempts at the electrophoretic determination of these compounds. For this purpose, an extraction procedure for the optimized separation and simultaneous determination of seven steroid hormones in urine samples has been investigated. The isolation of analytes from biological samples was performed by liquid-liquid extraction (LLE with dichloromethane and compared to solid phase extraction (SPE with C18 and hydrophilic-lipophilic balance (HLB columns. To separate all the analytes a micellar electrokinetic capillary chromatography (MECK technique was employed. For full separation of all the analytes a running buffer (pH 9.2, composed of 10 mM sodium tetraborate decahydrate (borax, 50 mM sodium dodecyl sulfate (SDS, and 10% methanol was selected. The methodology developed in this work for the determination of steroid hormones meets all the requirements of analytical methods. The applicability of the method has been confirmed for the analysis of urine samples collected from volunteers—both men and women (students, amateur bodybuilders, using and not applying steroid doping. The data obtained during this work can be successfully used for further research on the determination of steroid hormones in urine samples.

  11. U.S. Geological Survey Noble Gas Laboratory’s standard operating procedures for the measurement of dissolved gas in water samples

    Science.gov (United States)

    Hunt, Andrew G.

    2015-08-12

    This report addresses the standard operating procedures used by the U.S. Geological Survey’s Noble Gas Laboratory in Denver, Colorado, U.S.A., for the measurement of dissolved gases (methane, nitrogen, oxygen, and carbon dioxide) and noble gas isotopes (helium-3, helium-4, neon-20, neon-21, neon-22, argon-36, argon-38, argon-40, kryton-84, krypton-86, xenon-103, and xenon-132) dissolved in water. A synopsis of the instrumentation used, procedures followed, calibration practices, standards used, and a quality assurance and quality control program is presented. The report outlines the day-to-day operation of the Residual Gas Analyzer Model 200, Mass Analyzer Products Model 215–50, and ultralow vacuum extraction line along with the sample handling procedures, noble gas extraction and purification, instrument measurement procedures, instrumental data acquisition, and calculations for the conversion of raw data from the mass spectrometer into noble gas concentrations per unit mass of water analyzed. Techniques for the preparation of artificial dissolved gas standards are detailed and coupled to a quality assurance and quality control program to present the accuracy of the procedures used in the laboratory.

  12. Solid-phase extraction and separation procedure for trace aluminum in water samples and its determination by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS).

    Science.gov (United States)

    Ciftci, Harun; Er, Cigdem

    2013-03-01

    In the present study, a separation/preconcentration procedure for determination of aluminum in water samples has been developed by using a new atomic absorption spectrometer concept with a high-intensity xenon short-arc lamp as continuum radiation source, a high-resolution double-echelle monochromator, and a charge-coupled device array detector. Sample solution pH, sample volume, flow rate of sample solution, volume, and concentration of eluent for solid-phase extraction of Al chelates with 4-[(dicyanomethyl)diazenyl] benzoic acid on polymeric resin (Duolite XAD-761) have been investigated. The adsorbed aluminum on resin was eluted with 5 mL of 2 mol L(-1) HNO(3) and its concentration was determined by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). Under the optimal conditions, limit of detection obtained with HR-CS FAAS and Line Source FAAS (LS-FAAS) were 0.49 μg L(-1) and 3.91 μg L(-1), respectively. The accuracy of the procedure was confirmed by analyzing certified materials (NIST SRM 1643e, Trace elements in water) and spiked real samples. The developed procedure was successfully applied to water samples.

  13. Data Set for the manuscript entitled, "Sample Processing Approach for Detection of Ricin in Surface Samples."

    Data.gov (United States)

    U.S. Environmental Protection Agency — Figure. This dataset is associated with the following publication: Shah, S., S. Kane, A.M. Erler, and T. Alfaro. Sample Processing Approach for Detection of Ricin in...

  14. 29 CFR 471.11 - What are the procedures for filing and processing a complaint?

    Science.gov (United States)

    2010-07-01

    ..., DEPARTMENT OF LABOR NOTIFICATION OF EMPLOYEE RIGHTS UNDER FEDERAL LABOR LAWS OBLIGATIONS OF FEDERAL CONTRACTORS AND SUBCONTRACTORS; NOTIFICATION OF EMPLOYEE RIGHTS UNDER FEDERAL LABOR LAWS General Enforcement... 29 Labor 2 2010-07-01 2010-07-01 false What are the procedures for filing and processing a...

  15. A solid phase extraction-ion chromatography with conductivity detection procedure for determining cationic surfactants in surface water samples.

    Science.gov (United States)

    Olkowska, Ewa; Polkowska, Żaneta; Namieśnik, Jacek

    2013-11-15

    A new analytical procedure for the simultaneous determination of individual cationic surfactants (alkyl benzyl dimethyl ammonium chlorides) in surface water samples has been developed. We describe this methodology for the first time: it involves the application of solid phase extraction (SPE-for sample preparation) coupled with ion chromatography-conductivity detection (IC-CD-for the final determination). Mean recoveries of analytes between 79% and 93%, and overall method quantification limits in the range from 0.0018 to 0.038 μg/mL for surface water and CRM samples were achieved. The methodology was applied to the determination of individual alkyl benzyl quaternary ammonium compounds in environmental samples (reservoir water) and enables their presence in such types of waters to be confirmed. In addition, it is a simpler, less time-consuming, labour-intensive, avoiding use of toxic chloroform and significantly less expensive methodology than previously described approaches (liquid-liquid extraction coupled with liquid chromatography-mass spectrometry). Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Sample size calculation in metabolic phenotyping studies.

    Science.gov (United States)

    Billoir, Elise; Navratil, Vincent; Blaise, Benjamin J

    2015-09-01

    The number of samples needed to identify significant effects is a key question in biomedical studies, with consequences on experimental designs, costs and potential discoveries. In metabolic phenotyping studies, sample size determination remains a complex step. This is due particularly to the multiple hypothesis-testing framework and the top-down hypothesis-free approach, with no a priori known metabolic target. Until now, there was no standard procedure available to address this purpose. In this review, we discuss sample size estimation procedures for metabolic phenotyping studies. We release an automated implementation of the Data-driven Sample size Determination (DSD) algorithm for MATLAB and GNU Octave. Original research concerning DSD was published elsewhere. DSD allows the determination of an optimized sample size in metabolic phenotyping studies. The procedure uses analytical data only from a small pilot cohort to generate an expanded data set. The statistical recoupling of variables procedure is used to identify metabolic variables, and their intensity distributions are estimated by Kernel smoothing or log-normal density fitting. Statistically significant metabolic variations are evaluated using the Benjamini-Yekutieli correction and processed for data sets of various sizes. Optimal sample size determination is achieved in a context of biomarker discovery (at least one statistically significant variation) or metabolic exploration (a maximum of statistically significant variations). DSD toolbox is encoded in MATLAB R2008A (Mathworks, Natick, MA) for Kernel and log-normal estimates, and in GNU Octave for log-normal estimates (Kernel density estimates are not robust enough in GNU octave). It is available at http://www.prabi.fr/redmine/projects/dsd/repository, with a tutorial at http://www.prabi.fr/redmine/projects/dsd/wiki. © The Author 2015. Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  17. Reference volumetric samples of gamma-spectroscopic sources

    International Nuclear Information System (INIS)

    Taskaev, E.; Taskaeva, M.; Grigorov, T.

    1993-01-01

    The purpose of this investigation is to determine the requirements for matrices of reference volumetric radiation sources necessary for detector calibration. The first stage of this determination consists in analysing some available organic and nonorganic materials. Different sorts of food, grass, plastics, minerals and building materials have been considered, taking into account the various procedures of their processing (grinding, screening, homogenizing) and their properties (hygroscopy, storage life, resistance to oxidation during gamma sterilization). The procedures of source processing, sample preparation, matrix irradiation and homogenization have been determined. A rotation homogenizing device has been elaborated enabling to homogenize the matrix activity irrespective of the vessel geometry. 33 standard volumetric radioactive sources have been prepared: 14 - on organic matrix and 19 - on nonorganic matrix. (author)

  18. Highly oriented Bi-system bulk sample prepared by a decomposition-crystallization process

    International Nuclear Information System (INIS)

    Xi Zhengping; Zhou Lian; Ji Chunlin

    1992-01-01

    A decomposition-crystallization method, preparing highly oriented Bi-system bulk sample is reported. The effects of processing parameter, decomposition temperature, cooling rate and post-treatment condition on texture and superconductivity are investigated. The method has successfully prepared highly textured Bi-system bulk samples. High temperature annealing does not destroy the growing texture, but the cooling rate has some effect on texture and superconductivity. Annealing in N 2 /O 2 atmosphere can improve superconductivity of the textured sample. The study on the superconductivity of the Bi(Pb)-Sr-Ca-Cu-O bulk material has been reported in numerous papers. The research on J c concentrates on the tape containing the 2223 phase, with very few studies on the J c of bulk sample. The reason for the lack of studies is that the change of superconducting phases at high temperatures has not been known. The authors have reported that the 2212 phase incongruently melted at about 875 degrees C and proceeded to orient the c-axis perpendicular to the surface in the process of crystallization of the 2212 phase. Based on that result, a decomposition-crystallization method was proposed to prepare highly oriented Bi-system bulk sample. In this paper, the process is described in detail and the effects of processing parameters on texture and superconductivity are reported

  19. Tank 241-AP-104 Grab Sampling and Analysis Plan

    International Nuclear Information System (INIS)

    TEMPLETON, A.M.

    2000-01-01

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for samples obtained from tank 241-AP-104. The purpose of this sampling event is to obtain information about the characteristics of the contents of 241-AP-104 required to provide sample material to the Waste Treatment Contractor. Grab samples will be obtained from riser 001 to provide sufficient material for the chemical analyses and tests required to satisfy these data quality objectives and ICD-23. The 222-S Laboratory will receive samples; composite the samples; perform chemical analyses on composite samples; and provide samples to the Waste Treatment Contractor and the Process Chemistry Laboratory. The Process Chemistry Laboratory at the 222-S Laboratory Complex will perform process tests to evaluate the behavior of the 241-AP-104 waste undergoing the retrieval and treatment scenarios defined in the applicable DQOs. The Waste Treatment Contractor will perform process verification and waste form qualification tests. Requirements for analyses of samples originating in the L and H DQO process tests will be documented in the corresponding test plan (Person 2000) and are not within the scope of this SAP. This report provides the general methodology and procedures to be used in the preparation, retrieval, transport, analysis, and reporting of results from grab samples retrieved from tank 241-AP-104

  20. Clinical procedure for colon carcinoma tissue sampling directly affects the cancer marker-capacity of VEGF family members

    International Nuclear Information System (INIS)

    Pringels, Sarah; Van Damme, Nancy; De Craene, Bram; Pattyn, Piet; Ceelen, Wim; Peeters, Marc; Grooten, Johan

    2012-01-01

    mRNA levels of members of the Vascular Endothelial Growth Factor family (VEGF-A, -B, -C, -D, Placental Growth Factor/PlGF) have been investigated as tissue-based markers of colon cancer. These studies, which used specimens obtained by surgical resection or colonoscopic biopsy, yielded contradictory results. We studied the effect of the sampling method on the marker accuracy of VEGF family members. Comparative RT-qPCR analysis was performed on healthy colon and colon carcinoma samples obtained by biopsy (n = 38) or resection (n = 39) to measure mRNA expression levels of individual VEGF family members. mRNA levels of genes encoding the eicosanoid enzymes cyclooxygenase 2 (COX2) and 5-lipoxygenase (5-LOX) and of genes encoding the hypoxia markers glucose transporter 1 (GLUT-1) and carbonic anhydrase IX (CAIX) were included as markers for cellular stress and hypoxia. Expression levels of COX2, 5-LOX, GLUT-1 and CAIX revealed the occurrence in healthy colon resection samples of hypoxic cellular stress and a concurrent increment of basal expression levels of VEGF family members. This increment abolished differential expression of VEGF-B and VEGF-C in matched carcinoma resection samples and created a surgery-induced underexpression of VEGF-D. VEGF-A and PlGF showed strong overexpression in carcinoma samples regardless of the sampling method. Sampling-induced hypoxia in resection samples but not in biopsy samples affects the marker-reliability of VEGF family members. Therefore, biopsy samples provide a more accurate report on VEGF family mRNA levels. Furthermore, this limited expression analysis proposes VEGF-A and PlGF as reliable, sampling procedure insensitive mRNA-markers for molecular diagnosis of colon cancer

  1. Relationships between processing delay and microbial load of broiler neck skin samples.

    Science.gov (United States)

    Lucianez, A; Holmes, M A; Tucker, A W

    2010-01-01

    The measurable microbial load on poultry carcasses during processing is determined by a number of factors including farm or origin, processing hygiene, and external temperature. This study investigated associations between carcass microbial load and progressive delays to processing. A total of 30 carcasses were delayed immediately after defeathering and before evisceration in a commercial abattoir in groups of five, and were held at ambient temperature for 1, 2, 3, 4, 6, and 8 h. Delayed carcasses were reintroduced to the processing line, and quantitative assessment of total viable count, coliforms, Staphylococcus aureus, and Pseudomonas spp. was undertaken on neck skin flap samples collected after carcass chilling and then pooled for each group. Sampling was repeated on 5 separate days, and the data were combined. Significant increases in total viable count (P = 0.001) and coliforms (P = 0.004), but not for S. aureus or Pseudomonas loads, were observed across the 8-h period of delay. In line with previous studies, there was significant variation in microbiological data according to sampling day. In conclusion, there is a significant and measurable decline in microbiological status of uneviscerated but defeathered poultry carcasses after an 8-h delay, but the variability of sampling results, reflecting the wide range of factors that impact microbial load, means that it is not possible to determine maximum or minimum acceptable periods of processing delay based on this criterion alone.

  2. Statistical sampling method for releasing decontaminated vehicles

    International Nuclear Information System (INIS)

    Lively, J.W.; Ware, J.A.

    1996-01-01

    Earth moving vehicles (e.g., dump trucks, belly dumps) commonly haul radiologically contaminated materials from a site being remediated to a disposal site. Traditionally, each vehicle must be surveyed before being released. The logistical difficulties of implementing the traditional approach on a large scale demand that an alternative be devised. A statistical method (MIL-STD-105E, open-quotes Sampling Procedures and Tables for Inspection by Attributesclose quotes) for assessing product quality from a continuous process was adapted to the vehicle decontamination process. This method produced a sampling scheme that automatically compensates and accommodates fluctuating batch sizes and changing conditions without the need to modify or rectify the sampling scheme in the field. Vehicles are randomly selected (sampled) upon completion of the decontamination process to be surveyed for residual radioactive surface contamination. The frequency of sampling is based on the expected number of vehicles passing through the decontamination process in a given period and the confidence level desired. This process has been successfully used for 1 year at the former uranium mill site in Monticello, Utah (a CERCLA regulated clean-up site). The method forces improvement in the quality of the decontamination process and results in a lower likelihood that vehicles exceeding the surface contamination standards are offered for survey. Implementation of this statistical sampling method on Monticello Projects has resulted in more efficient processing of vehicles through decontamination and radiological release, saved hundreds of hours of processing time, provided a high level of confidence that release limits are met, and improved the radiological cleanliness of vehicles leaving the controlled site

  3. Mediation and Due Process Procedures in Special Education: An Analysis of State Policies. Final Report. Project FORUM.

    Science.gov (United States)

    Ahearn, Eileen M.

    This survey of 50 states and 3 of 10 non-state U.S. jurisdictions concerning state due process procedures focuses mainly on the use of mediation as a form of dispute resolution that offers an alternative to due process hearings in special education. A background section discusses the definition of mediation and the mediation process. Survey…

  4. Sampling phased array a new technique for signal processing and ultrasonic imaging

    OpenAIRE

    Bulavinov, A.; Joneit, D.; Kröning, M.; Bernus, L.; Dalichow, M.H.; Reddy, K.M.

    2006-01-01

    Different signal processing and image reconstruction techniques are applied in ultrasonic non-destructive material evaluation. In recent years, rapid development in the fields of microelectronics and computer engineering lead to wide application of phased array systems. A new phased array technique, called "Sampling Phased Array" has been developed in Fraunhofer Institute for non-destructive testing. It realizes unique approach of measurement and processing of ultrasonic signals. The sampling...

  5. Assessment of the effects of different sample perfusion procedures on phase-contrast tomographic images of mouse spinal cord

    Science.gov (United States)

    Stefanutti, E.; Sierra, A.; Miocchi, P.; Massimi, L.; Brun, F.; Maugeri, L.; Bukreeva, I.; Nurmi, A.; Begani Provinciali, G.; Tromba, G.; Gröhn, O.; Giove, F.; Cedola, A.; Fratini, M.

    2018-03-01

    Synchrotron X-ray Phase Contrast micro-Tomography (SXrPCμT) is a powerful tool in the investigation of biological tissues, including the central nervous system (CNS), and it allows to simultaneously detect the vascular and neuronal network avoiding contrast agents or destructive sample preparations. However, specific sample preparation procedures aimed to optimize the achievable contrast- and signal-to-noise ratio (CNR and SNR, respectively) are required. Here we report and discuss the effects of perfusion with two different fixative agents (ethanol and paraformaldehyde) and with a widely used contrast medium (MICROFIL®) on mouse spinal cord. As a main result, we found that ethanol enhances contrast at the grey/white matter interface and increases the contrast in correspondence of vascular features and fibres, thus providing an adequate spatial resolution to visualise the vascular network at the microscale. On the other hand, ethanol is known to induce tissue dehydration, likely reducing cell dimensions below the spatial resolution limit imposed by the experimental technique. Nonetheless, neurons remain well visible using either perfused paraformaldehyde or MICROFIL® compound, as these latter media do not affect tissues with dehydration effects. Paraformaldehyde appears as the best compromise: it is not a contrast agent, like MICROFIL®, but it is less invasive than ethanol and permits to visualise well both cells and blood vessels. However, a quantitative estimation of the relative grey matter volume of each sample has led us to conclude that no significant alterations in the grey matter extension compared to the white matter occur as a consequence of the perfusion procedures tested in this study.

  6. XRF analysis of mineralised samples

    International Nuclear Information System (INIS)

    Ahmedali, T.

    2002-01-01

    Full text: Software now supplied by instrument manufacturers has made it practical and convenient for users to analyse unusual samples routinely. Semiquantitative scanning software can be used for rapid preliminary screening of elements ranging from Carbon to Uranium, prior to assigning mineralised samples to an appropriate quantitative analysis routine. The general quality and precision of analytical results obtained from modern XRF spectrometers can be significantly enhanced by several means: a. Modifications in preliminary sample preparation can result in less contamination from crushing and grinding equipment. Optimised techniques of actual sample preparation can significantly increase precision of results. b. Employment of automatic data recording balances and the use of catch weights during sample preparation reduces technician time as well as weighing errors. * c. Consistency of results can be improved significantly by the use of appropriate stable drift monitors with a statistically significant content of the analyte d. A judicious selection of kV/mA combinations, analysing crystals, primary beam filters, collimators, peak positions, accurate background correction and peak overlap corrections, followed by the use of appropriate matrix correction procedures. e. Preventative maintenance procedures for XRF spectrometers and ancillary equipment, which can also contribute significantly to reducing instrument down times, are described. Examples of various facets of sample processing routines are given from the XRF spectrometer component of a multi-instrument analytical university facility, which provides XRF data to 17 Canadian universities. Copyright (2002) Australian X-ray Analytical Association Inc

  7. Sampling and Timing: A Task for the Environmetal Process

    NARCIS (Netherlands)

    Hilderink, G.H.; Broenink, Johannes F.

    2003-01-01

    Sampling and timing is considered a responsibility of the environment of controller software. In this paper we will illustrate a concept whereby an environmental process and multi-way events play an important role in applying timing for untimed CSP software architectures. We use this timing concept

  8. The characteristics and mechanisms of Au nanoparticles processed by functional centrifugal procedures

    Science.gov (United States)

    Shiau, Bo-Wen; Lin, Chien-Hung; Liao, Ying-Yen; Lee, Ya-Rong; Liu, Shih-Hao; Ding, Wei-Cheng; Lee, Jia-Ren

    2018-05-01

    In this work, the optical properties of Au nanoparticles processed by centrifugation techniques are studied. Most of the literature related to the control of nanoparticle size has focused on different preparation parameters; however, the wide size distribution is commonly an issue for follow-up investigations and further applications. Therefore, we developed a method in which specific-diameter particles can be effectively separated using different centrifugal procedures. The initial nanoparticle solution with a primary absorption peak at 534 nm is separated into discernible resonance wavelengths from 526 to 537 nm, with corresponding particle sizes from 30 to 55 nm. For the atomic force microscopy analysis of nanoparticle size, a dry cetyltrimethylammonium bromide (CTAB) film often covers the particles and interferes with the measurement; thus, CTAB has to be removed. However, if too much CTAB is removed, the surface of the Au nanoparticle becomes unstable, and the particles aggregate. Accordingly, we used UV spectroscopy to monitor the CTAB content; properly adjust the rotational speed and the number of centrifugation stages; and design a method that can effectively remove impurities, avoid clustering, and enable particle size measurement. The usually complicated procedures and high cost of preparation of specific-size Au nanoparticles are greatly simplified and reduced by the convenient extraction process proposed in this work, which would benefit related research and applications.

  9. Concurrent Data Elicitation Procedures, Processes, and the Early Stages of L2 Learning: A Critical Overview

    Science.gov (United States)

    Leow, Ronald P.; Grey, Sarah; Marijuan, Silvia; Moorman, Colleen

    2014-01-01

    Given the current methodological interest in eliciting direct data on the cognitive processes L2 learners employ as they interact with L2 data during the early stages of the learning process, this article takes a critical and comparative look at three concurrent data elicitation procedures currently employed in the SLA literature: Think aloud (TA)…

  10. 40 CFR 90.413 - Exhaust sample procedure-gaseous components.

    Science.gov (United States)

    2010-07-01

    ...-analysis values. (3) Measure and record HC, CO, CO2, and NOX concentrations in the exhaust sample bag(s...-analysis values. (7) Collect background HC, CO, CO2, and NOX in a sample bag (for dilute exhaust sampling...: (1) For dilute grab (“bag”) sample analysis, the analyzer response must be stable at greater than 99...

  11. Down sampled signal processing for a B Factory bunch-by-bunch feedback system

    International Nuclear Information System (INIS)

    Hindi, H.; Hosseini, W.; Briggs, D.; Fox, J.; Hutton, A.

    1992-03-01

    A bunch-by-bunch feedback scheme is studied for damping coupled bunch synchrotron oscillations in the proposed PEP II B Factory. The quasi-linear feedback systems design incorporates a phase detector to provide a quantized measure of bunch phase, digital signal processing to compute an error correction signal and a kicker system to correct the energy of the bunches. A farm of digital processors, operating in parallel, is proposed to compute correction signals for the 1658 bunches of the B Factory. This paper studies the use of down sampled processing to reduce the computational complexity of the feedback system. We present simulation results showing the effect of down sampling on beam dynamics. Results show that down sampled processing can reduce the scale of the processing task by a factor of 10

  12. DEFENSE WASTE PROCESSING FACILITY ANALYTICAL METHOD VERIFICATION FOR THE SLUDGE BATCH 5 QUALIFICATION SAMPLE

    International Nuclear Information System (INIS)

    Click, D; Tommy Edwards, T; Henry Ajo, H

    2008-01-01

    For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) performs confirmation of the applicability of the digestion method to be used by the DWPF lab for elemental analysis of Sludge Receipt and Adjustment Tank (SRAT) receipt samples and SRAT product process control samples. DWPF SRAT samples are typically dissolved using a room temperature HF-HNO3 acid dissolution (i.e., DWPF Cold Chem Method, see Procedure SW4-15.201) and then analyzed by inductively coupled plasma - atomic emission spectroscopy (ICP-AES). This report contains the results and comparison of data generated from performing the Aqua Regia (AR), Sodium Peroxide/Hydroxide Fusion (PF) and DWPF Cold Chem (CC) method digestion of Sludge Batch 5 (SB5) SRAT Receipt and SB5 SRAT Product samples. The SB5 SRAT Receipt and SB5 SRAT Product samples were prepared in the SRNL Shielded Cells, and the SRAT Receipt material is representative of the sludge that constitutes the SB5 Batch composition. This is the sludge in Tank 51 that is to be transferred into Tank 40, which will contain the heel of Sludge Batch 4 (SB4), to form the SB5 Blend composition. The results for any one particular element should not be used in any way to identify the form or speciation of a particular element in the sludge or used to estimate ratios of compounds in the sludge. A statistical comparison of the data validates the use of the DWPF CC method for SB5 Batch composition. However, the difficulty that was encountered in using the CC method for SB4 brings into question the adequacy of CC for the SB5 Blend. Also, it should be noted that visible solids remained in the final diluted solutions of all samples digested by this method at SRNL (8 samples total), which is typical for the DWPF CC method but not seen in the other methods. Recommendations to the DWPF for application to SB5 based on studies to date: (1) A dissolution study should be performed on the WAPS

  13. Adaptation and innovation: a grounded theory study of procedural variation in the academic surgical workplace.

    Science.gov (United States)

    Apramian, Tavis; Watling, Christopher; Lingard, Lorelei; Cristancho, Sayra

    2015-10-01

    Surgical research struggles to describe the relationship between procedural variations in daily practice and traditional conceptualizations of evidence. The problem has resisted simple solutions, in part, because we lack a solid understanding of how surgeons conceptualize and interact around variation, adaptation, innovation, and evidence in daily practice. This grounded theory study aims to describe the social processes that influence how procedural variation is conceptualized in the surgical workplace. Using the constructivist grounded theory methodology, semi-structured interviews with surgeons (n = 19) from four North American academic centres were collected and analysed. Purposive sampling targeted surgeons with experiential knowledge of the role of variations in the workplace. Theoretical sampling was conducted until a theoretical framework representing key processes was conceptually saturated. Surgical procedural variation was influenced by three key processes. Seeking improvement was shaped by having unsolved procedural problems, adapting in the moment, and pursuing personal opportunities. Orienting self and others to variations consisted of sharing stories of variations with others, taking stock of how a variation promoted personal interests, and placing trust in peers. Acting under cultural and material conditions was characterized by being wary, positioning personal image, showing the logic of a variation, and making use of academic resources to do so. Our findings include social processes that influence how adaptations are incubated in surgical practice and mature into innovations. This study offers a language for conceptualizing the sociocultural influences on procedural variations in surgery. Interventions to change how surgeons interact with variations on a day-to-day basis should consider these social processes in their design. © 2015 John Wiley & Sons, Ltd.

  14. Gaussian process based intelligent sampling for measuring nano-structure surfaces

    Science.gov (United States)

    Sun, L. J.; Ren, M. J.; Yin, Y. H.

    2016-09-01

    Nanotechnology is the science and engineering that manipulate matters at nano scale, which can be used to create many new materials and devices with a vast range of applications. As the nanotech product increasingly enters the commercial marketplace, nanometrology becomes a stringent and enabling technology for the manipulation and the quality control of the nanotechnology. However, many measuring instruments, for instance scanning probe microscopy, are limited to relatively small area of hundreds of micrometers with very low efficiency. Therefore some intelligent sampling strategies should be required to improve the scanning efficiency for measuring large area. This paper presents a Gaussian process based intelligent sampling method to address this problem. The method makes use of Gaussian process based Bayesian regression as a mathematical foundation to represent the surface geometry, and the posterior estimation of Gaussian process is computed by combining the prior probability distribution with the maximum likelihood function. Then each sampling point is adaptively selected by determining the position which is the most likely outside of the required tolerance zone among the candidates and then inserted to update the model iteratively. Both simulationson the nominal surface and manufactured surface have been conducted on nano-structure surfaces to verify the validity of the proposed method. The results imply that the proposed method significantly improves the measurement efficiency in measuring large area structured surfaces.

  15. 23 CFR 630.1008 - State-level processes and procedures.

    Science.gov (United States)

    2010-04-01

    ..., data and information resources, training, and periodic evaluation enable a systematic approach for... management procedures. States should develop and implement systematic procedures to assess work zone impacts... resources that are necessary to support these activities. (d) Training. States shall require that personnel...

  16. Validation of natural language processing to extract breast cancer pathology procedures and results

    Directory of Open Access Journals (Sweden)

    Arika E Wieneke

    2015-01-01

    Full Text Available Background: Pathology reports typically require manual review to abstract research data. We developed a natural language processing (NLP system to automatically interpret free-text breast pathology reports with limited assistance from manual abstraction. Methods: We used an iterative approach of machine learning algorithms and constructed groups of related findings to identify breast-related procedures and results from free-text pathology reports. We evaluated the NLP system using an all-or-nothing approach to determine which reports could be processed entirely using NLP and which reports needed manual review beyond NLP. We divided 3234 reports for development (2910, 90%, and evaluation (324, 10% purposes using manually reviewed pathology data as our gold standard. Results: NLP correctly coded 12.7% of the evaluation set, flagged 49.1% of reports for manual review, incorrectly coded 30.8%, and correctly omitted 7.4% from the evaluation set due to irrelevancy (i.e. not breast-related. Common procedures and results were identified correctly (e.g. invasive ductal with 95.5% precision and 94.0% sensitivity, but entire reports were flagged for manual review because of rare findings and substantial variation in pathology report text. Conclusions: The NLP system we developed did not perform sufficiently for abstracting entire breast pathology reports. The all-or-nothing approach resulted in too broad of a scope of work and limited our flexibility to identify breast pathology procedures and results. Our NLP system was also limited by the lack of the gold standard data on rare findings and wide variation in pathology text. Focusing on individual, common elements and improving pathology text report standardization may improve performance.

  17. A rapid sample decomposition procedure for bromo-heavies containing ferruginous material: determination of REEs and thorium by ICP-AES

    International Nuclear Information System (INIS)

    Khorge, C.R.; Murugesan, P.; Chakrapani, G.

    2013-01-01

    A rapid method of sample decomposition and dissolution for bromoform heavies is described for the determination of REEs and thorium by inductively coupled plasma- optical emission spectrometry. For application to geochemical exploration to achieve the high sample throughput; a simple and rapid analytical procedure is a prerequisite. In order to speed-up the existing methodology, phosphate fusion was introduced for decomposition of samples. In the proposed method, bromoform-heavies material are fused with 1:1 mixture of sodium dihydrogen orthophosphate and tetra-sodium pyrophosphate and dissolved in distilled water. After disintegration of melt, the solution was subjected to oxalate precipitation followed by R 2 O 3 separation for separating the REEs from major matrix interfering elements. The rare earth elements and thorium in the resultant solution were determined by ICP-OES. The results are compared with the results obtained by well-established existing dissolution procedures involving HF-HCl-HClO 4 acid treatment and NaF/KHF 2 fusion followed by H 2 SO 4 acid fuming. The accuracy of the method was evaluated by doping the phosphate blank with known amount of REEs and comparing the recoveries obtained using the present method. The method is simple, rapid and is suitable for the routine determination of REEs and Th in bromoform-heavies. The RSD of the method was found to be within 1-3% for Th and REEs by ICP-AES. (author)

  18. A single-centre experience of the implementation of adrenal vein sampling procedure: the impact on the diagnostic work-up in primary aldosteronism

    NARCIS (Netherlands)

    Kadziela, J.; Prejbisz, A.; Michalowska, I.; Kolodziejczyk-Kruk, S.; Schultze Kool, L.J.; Kabat, M.; Janaszek-Sitkowska, H.; Toutounchi, S.; Galazka, Z.; Ambroziak, U.; Bednarczuk, T.; Ptasinska-Wnuk, D.; Hoffmann, M.; Januszewicz, M.; Januszewicz, A.; Witkowski, A.

    2017-01-01

    BACKGROUND: Primary aldosteronism is one of the most common causes of secondary hypertension. Adrenal vein sampling (AVS) remains a "gold standard" procedure in differentiation between unilateral (adenoma) and bilateral (hyperplasia) disease. AIM: The aim of this study was to present our

  19. Soil Gas Sampling

    Science.gov (United States)

    Field Branches Quality System and Technical Procedures: This document describes general and specific procedures, methods and considerations to be used and observed when collecting soil gas samples for field screening or laboratory analysis.

  20. Double Shell Tank (DST) Process Waste Sampling Subsystem Definition Report

    International Nuclear Information System (INIS)

    RASMUSSEN, J.H.

    2000-01-01

    This report defines the Double-Shell Tank (DST) Process Waste Sampling Subsystem (PWSS). This subsystem definition report fully describes and identifies the system boundaries of the PWSS. This definition provides a basis for developing functional, performance, and test requirements (i.e., subsystem specification), as necessary, for the PWSS. The resultant PWSS specification will include the sampling requirements to support the transfer of waste from the DSTs to the Privatization Contractor during Phase 1 of Waste Feed Delivery

  1. Capillary absorption spectrometer and process for isotopic analysis of small samples

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, M. Lizabeth; Kelly, James F.; Sams, Robert L.; Moran, James J.; Newburn, Matthew K.; Blake, Thomas A.

    2016-03-29

    A capillary absorption spectrometer and process are described that provide highly sensitive and accurate stable absorption measurements of analytes in a sample gas that may include isotopologues of carbon and oxygen obtained from gas and biological samples. It further provides isotopic images of microbial communities that allow tracking of nutrients at the single cell level. It further targets naturally occurring variations in carbon and oxygen isotopes that avoids need for expensive isotopically labeled mixtures which allows study of samples taken from the field without modification. The method also permits sampling in vivo permitting real-time ambient studies of microbial communities.

  2. Environmental sampling accounting at the Savannah River Plant

    International Nuclear Information System (INIS)

    Zeigler, C.C.; Wood, M.B.

    1978-06-01

    At the Savannah River Plant Environmental Monitoring Laboratories, a computer-based systematic accounting method was developed to ensure that all scheduled samples are collected, processed through the laboratory, and counted without delay. The system employs an IBM 360/195 computer with a magnetic tape master file, an on-line disk file, and cathode ray tube (CRT) terminals. Scheduling and accounting are accomplished by using computer-generated schedules, collection labels, and output/input cards. For each scheduled sample and analysis, a printed card is issued for collection, laboratory analysis, and counting. The cards also contain information needed by personnel performing the jobs, such as sample location, aliquot to be processed, or procedure number. Manual entries are made on the cards when each step in the process is completed. Additional pertinent data are also manually entered on the cards; e.g., entries are made explaining why a sample is not collected, the sample aliquot in the event a nonstandard aliquot is processed, field measurement results, and analytical results. These manually entered data are keypunched and read into the computer files. The computer files are audited daily, and summaries of samples not processed in pre-established normal time intervals are issued. The progress of sample analyses can also be readily determined at any time using the CRT terminal. Historic data are also maintained on magnetic tape and workload summaries are issued showing the number of samples and number of determinations per month

  3. Cluster analysis of commercial samples of Bauhinia spp. using HPLC-UV/PDA and MCR-ALS/PCA without peak alignment procedure.

    Science.gov (United States)

    Ardila, Jorge Armando; Funari, Cristiano Soleo; Andrade, André Marques; Cavalheiro, Alberto José; Carneiro, Renato Lajarim

    2015-01-01

    Bauhinia forficata Link. is recognised by the Brazilian Health Ministry as a treatment of hypoglycemia and diabetes. Analytical methods are useful to assess the plant identity due the similarities found in plants from Bauhinia spp. HPLC-UV/PDA in combination with chemometric tools is an alternative widely used and suitable for authentication of plant material, however, the shifts of retention times for similar compounds in different samples is a problem. To perform comparisons between the authentic medicinal plant (Bauhinia forficata Link.) and samples commercially available in drugstores claiming to be "Bauhinia spp. to treat diabetes" and to evaluate the performance of multivariate curve resolution - alternating least squares (MCR-ALS) associated to principal component analysis (PCA) when compared to pure PCA. HPLC-UV/PDA data obtained from extracts of leaves were evaluated employing a combination of MCR-ALS and PCA, which allowed the use of the full chromatographic and spectrometric information without the need of peak alignment procedures. The use of MCR-ALS/PCA showed better results than the conventional PCA using only one wavelength. Only two of nine commercial samples presented characteristics similar to the authentic Bauhinia forficata spp., considering the full HPLC-UV/PDA data. The combination of MCR-ALS and PCA is very useful when applied to a group of samples where a general alignment procedure could not be applied due to the different chromatographic profiles. This work also demonstrates the need of more strict control from the health authorities regarding herbal products available on the market. Copyright © 2015 John Wiley & Sons, Ltd.

  4. Procedure for Process Management in supply chain of fisheries products. Application in the "Empresa Pesquera Sancti Spíritus".

    Directory of Open Access Journals (Sweden)

    Yenisel Machín León

    2013-03-01

    Full Text Available The general procedure for managing supply chains by processes of fishery products in steak chain of Claria, increases levels of reliability of its component processes and its effectiveness, and impacts on the level of customer service. With the diagnosis, is defined and identified logistics processes and maturity profiles of these, with the use of Quality Function Deployment, Analysis and Failure Mode Effects and principles of the SCOR model. Surveys were used, brainstorming and interviews to gather information. The research gives a priority for process management of supply chain and logistics management, according to the reliability and criticality of the processes associated with certain level of maturity, quality customer service and decision making, depending on the nature process of being analyzed. The paper shows the feasibility of implementing the first phase of the general procedure to manage supply chains by processes of flow production, and the gradual deterioration of technology. It is made an improvement proposal.

  5. Quality evaluation of processed clay soil samples | Steiner-Asiedu ...

    African Journals Online (AJOL)

    Introduction: This study assessed the microbial quality of clay samples sold on two of the major Ghanaian markets. Methods: The study was a cross-sectional assessing the evaluation of processed clay and effects it has on the nutrition of the consumers in the political capital town of Ghana. The items for the examination was ...

  6. Patient radiation dose audits for fluoroscopically guided interventional procedures

    International Nuclear Information System (INIS)

    Balter, Stephen; Rosenstein, Marvin; Miller, Donald L.; Schueler, Beth; Spelic, David

    2011-01-01

    Purpose: Quality management for any use of medical x-ray imaging should include monitoring of radiation dose. Fluoroscopically guided interventional (FGI) procedures are inherently clinically variable and have the potential for inducing deterministic injuries in patients. The use of a conventional diagnostic reference level is not appropriate for FGI procedures. A similar but more detailed quality process for management of radiation dose in FGI procedures is described. Methods: A method that takes into account both the inherent variability of FGI procedures and the risk of deterministic injuries from these procedures is suggested. The substantial radiation dose level (SRDL) is an absolute action level (with regard to patient follow-up) below which skin injury is highly unlikely and above which skin injury is possible. The quality process for FGI procedures collects data from all instances of a given procedure from a number of facilities into an advisory data set (ADS). An individual facility collects a facility data set (FDS) comprised of all instances of the same procedure at that facility. The individual FDS is then compared to the multifacility ADS with regard to the overall shape of the dose distributions and the percent of instances in both the ADS and the FDS that exceed the SRDL. Results: Samples of an ADS and FDS for percutaneous coronary intervention, using the dose metric of reference air kerma (K a,r ) (i.e., the cumulative air kerma at the reference point), are used to illustrate the proposed quality process for FGI procedures. Investigation is warranted whenever the FDS is noticeably different from the ADS for the specific FGI procedure and particularly in two circumstances: (1) When the facility's local median K a,r exceeds the 75th percentile of the ADS and (2) when the percent of instances where K a,r exceeds the facility-selected SRDL is greater for the FDS than for the ADS. Conclusions: Analysis of the two data sets (ADS and FDS) and of the

  7. An Interactive Procedure to Preserve the Desired Edges during the Image Processing of Noise Reduction

    Directory of Open Access Journals (Sweden)

    Lin-Tsang Lee

    2010-01-01

    Full Text Available The paper propose a new procedure including four stages in order to preserve the desired edges during the image processing of noise reduction. A denoised image can be obtained from a noisy image at the first stage of the procedure. At the second stage, an edge map can be obtained by the Canny edge detector to find the edges of the object contours. Manual modification of an edge map at the third stage is optional to capture all the desired edges of the object contours. At the final stage, a new method called Edge Preserved Inhomogeneous Diffusion Equation (EPIDE is used to smooth the noisy images or the previously denoised image at the first stage for achieving the edge preservation. The Optical Character Recognition (OCR results in the experiments show that the proposed procedure has the best recognition result because of the capability of edge preservation.

  8. Sources of variability in the determination by evaporation method of gross alpha activity in water samples

    Energy Technology Data Exchange (ETDEWEB)

    Baeza, A.; Corbacho, J.A. [LARUEX, Caceres (Spain). Environmental Radioactivity Lab.

    2013-07-01

    Determining the gross alpha activity concentration of water samples is one way to screen for waters whose radionuclide content is so high that its consumption could imply surpassing the Total Indicative Dose as defined in European Directive 98/83/EC. One of the most commonly used methods to prepare the sources to measure gross alpha activity in water samples is desiccation. Its main advantages are the simplicity of the procedure, the low cost of source preparation, and the possibility of simultaneously determining the gross beta activity. The preparation of the source, the construction of the calibration curves, and the measurement procedure itself involve, however, various factors that may introduce sufficient variability into the results to significantly affect the screening process. We here identify the main sources of this variability, and propose specific procedures to follow in the desiccation process that will reduce the uncertainties, and ensure that the result is indeed representative of the sum of the activities of the alpha emitters present in the sample. (orig.)

  9. DSMC multicomponent aerosol dynamics: Sampling algorithms and aerosol processes

    Science.gov (United States)

    Palaniswaamy, Geethpriya

    The post-accident nuclear reactor primary and containment environments can be characterized by high temperatures and pressures, and fission products and nuclear aerosols. These aerosols evolve via natural transport processes as well as under the influence of engineered safety features. These aerosols can be hazardous and may pose risk to the public if released into the environment. Computations of their evolution, movement and distribution involve the study of various processes such as coagulation, deposition, condensation, etc., and are influenced by factors such as particle shape, charge, radioactivity and spatial inhomogeneity. These many factors make the numerical study of nuclear aerosol evolution computationally very complicated. The focus of this research is on the use of the Direct Simulation Monte Carlo (DSMC) technique to elucidate the role of various phenomena that influence the nuclear aerosol evolution. In this research, several aerosol processes such as coagulation, deposition, condensation, and source reinforcement are explored for a multi-component, aerosol dynamics problem in a spatially homogeneous medium. Among the various sampling algorithms explored the Metropolis sampling algorithm was found to be effective and fast. Several test problems and test cases are simulated using the DSMC technique. The DSMC results obtained are verified against the analytical and sectional results for appropriate test problems. Results show that the assumption of a single mean density is not appropriate due to the complicated effect of component densities on the aerosol processes. The methods developed and the insights gained will also be helpful in future research on the challenges associated with the description of fission product and aerosol releases.

  10. Determination of Pesticides Residues in Cucumbers Grown in Greenhouse and the Effect of Some Procedures on Their Residues.

    Science.gov (United States)

    Leili, Mostafa; Pirmoghani, Amin; Samadi, Mohammad Taghi; Shokoohi, Reza; Roshanaei, Ghodratollah; Poormohammadi, Ali

    2016-11-01

    The objective of this study was to determine the residual concentrations of ethion and imidacloprid in cucumbers grown in greenhouse. The effect of some simple processing procedures on both ethion and imidacloprid residues were also studied. Ten active greenhouses that produce cucumber were randomly selected. Ethion and imidacloprid as the most widely used pesticides were measured in cucumber samples of studied greenhouses. Moreover, the effect of storing, washing, and peeling as simple processing procedures on both ethion and imidacloprid residues were investigated. One hour after pesticide application; the maximum residue levels (MRLs) of ethion and imidacloprid were higher than that of Codex standard level. One day after pesticide application, the levels of pesticides were decreased about 35 and 31% for ethion and imidacloprid, respectively, which still were higher than the MRL. Washing procedure led to about 51 and 42.5% loss in ethion and imidacloprid residues, respectively. Peeling procedure also led to highest loss of 93.4 and 63.7% in ethion and imidacloprid residues, respectively. The recovery for both target analytes was in the range between 88 and 102%. The residue values in collected samples one hour after pesticides application were higher than standard value. The storing, washing, and peeling procedures lead to the decrease of pesticide residues in greenhouse cucumbers. Among them, the peeling procedure has the greatest impact on residual reduction. Therefore, these procedures can be used as simple and effective processing techniques for reducing and removing pesticides from greenhouse products before their consumption.

  11. Evaluating strategic environmental assessment in the Netherlands: Content, process and procedure as indissoluble criteria for effectiveness

    NARCIS (Netherlands)

    M.W. van Buuren (Arwin); S.G. Nooteboom (Sibout)

    2009-01-01

    textabstractTo assess the effectiveness of strategic environmental assessment (SEA) we distinguish between its contribution to the quality of the ultimate policy choice (usefulness, applicability), the procedural quality of the planning process (transparency, timeliness) and the quality of

  12. The origins of levels-of-processing effects in a conceptual test: evidence for automatic influences of memory from the process-dissociation procedure.

    Science.gov (United States)

    Bergerbest, Dafna; Goshen-Gottstein, Yonatan

    2002-12-01

    In three experiments, we explored automatic influences of memory in a conceptual memory task, as affected by a levels-of-processing (LoP) manipulation. We also explored the origins of the LoP effect by examining whether the effect emerged only when participants in the shallow condition truncated the perceptual processing (the lexical-processing hypothesis) or even when the entire word was encoded in this condition (the conceptual-processing hypothesis). Using the process-dissociation procedure and an implicit association-generation task, we found that the deep encoding condition yielded higher estimates of automatic influences than the shallow condition. In support of the conceptual processing hypothesis, the LoP effect was found even when the shallow task did not lead to truncated processing of the lexical units. We suggest that encoding for meaning is a prerequisite for automatic processing on conceptual tests of memory.

  13. A Monte Carlo Sampling Technique for Multi-phonon Processes

    Energy Technology Data Exchange (ETDEWEB)

    Hoegberg, Thure

    1961-12-15

    A sampling technique for selecting scattering angle and energy gain in Monte Carlo calculations of neutron thermalization is described. It is supposed that the scattering is separated into processes involving different numbers of phonons. The number of phonons involved is first determined. Scattering angle and energy gain are then chosen by using special properties of the multi-phonon term.

  14. Summative Mass Analysis of Algal Biomass - Integration of Analytical Procedures: Laboratory Analytical Procedure (LAP)

    Energy Technology Data Exchange (ETDEWEB)

    Laurens, Lieve M. L.

    2016-01-13

    This procedure guides the integration of laboratory analytical procedures to measure algal biomass constituents in an unambiguous manner and ultimately achieve mass balance closure for algal biomass samples. Many of these methods build on years of research in algal biomass analysis.

  15. Standard practices for sampling uranium-Ore concentrate

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 These practices are intended to provide the nuclear industry with procedures for obtaining representative bulk samples from uranium-ore concentrates (UOC) (see Specification C967). 1.2 These practices also provide for obtaining a series of representative secondary samples from the original bulk sample for the determination of moisture and other test purposes, and for the preparation of pulverized analytical samples (see Test Methods C1022). 1.3 These practices consist of a number of alternative procedures for sampling and sample preparation which have been shown to be satisfactory through long experience in the nuclear industry. These procedures are described in the following order. Stage Procedure Section Primary Sampling One-stage falling stream 4 Two-stage falling stream 5 Auger 6 Secondary Sampling Straight-path (reciprocating) 7 Rotating (Vezin) 8, 9 Sample Preparation 10 Concurrent-drying 11-13 Natural moisture 14-16 Calcination 17, 18 Sample Packaging 19 Wax s...

  16. A New Image Processing Procedure Integrating PCI-RPC and ArcGIS-Spline Tools to Improve the Orthorectification Accuracy of High-Resolution Satellite Imagery

    Directory of Open Access Journals (Sweden)

    Hongying Zhang

    2016-10-01

    Full Text Available Given the low accuracy of the traditional remote sensing image processing software when orthorectifying satellite images that cover mountainous areas, and in order to make a full use of mutually compatible and complementary characteristics of the remote sensing image processing software PCI-RPC (Rational Polynomial Coefficients and ArcGIS-Spline, this study puts forward a new operational and effective image processing procedure to improve the accuracy of image orthorectification. The new procedure first processes raw image data into an orthorectified image using PCI with RPC model (PCI-RPC, and then the orthorectified image is further processed using ArcGIS with the Spline tool (ArcGIS-Spline. We used the high-resolution CBERS-02C satellite images (HR1 and HR2 scenes with a pixel size of 2 m acquired from Yangyuan County in Hebei Province of China to test the procedure. In this study, when separately using PCI-RPC and ArcGIS-Spline tools directly to process the HR1/HR2 raw images, the orthorectification accuracies (root mean square errors, RMSEs for HR1/HR2 images were 2.94 m/2.81 m and 4.65 m/4.41 m, respectively. However, when using our newly proposed procedure, the corresponding RMSEs could be reduced to 1.10 m/1.07 m. The experimental results demonstrated that the new image processing procedure which integrates PCI-RPC and ArcGIS-Spline tools could significantly improve image orthorectification accuracy. Therefore, in terms of practice, the new procedure has the potential to use existing software products to easily improve image orthorectification accuracy.

  17. Special study for the manual transfer of process samples from CPP [Chemical Processing Plant] 601 to RAL [Remote Analytical Laboratory

    International Nuclear Information System (INIS)

    Marts, D.J.

    1987-05-01

    A study of alternate methods to manually transport radioactive samples from their glove boxes to the Remote Analytical Laboratory (RAL) was conducted at the Idaho National Engineering Laboratory. The study was performed to mitigate the effects of a potential loss of sampling capabilities that could take place if a malfunction in the Pneumatic Transfer System (PTS) occurred. Samples are required to be taken from the cell glove boxes and analyzed at the RAL regardless of the operational status of the PTS. This paper documents the conclusions of the study and how a decision was reached that determined the best handling scenarios for manually transporting 15 mL vials of liquid process samples from the K, W, U, WG, or WH cell glove boxes in the Chemical Processing Plant (CPP) 601 to the RAL. This study of methods to manually remove the samples from the glove boxes, package them for safe shipment, transport them by the safest route, receive them at the RAL, and safely unload them was conducted by EG and G Idaho, Inc., for Westinghouse Idaho Nuclear Company as part of the Glove Box Sampling and Transfer System Project for the Fuel Processing Facilities Upgrade, Task 10, Subtask 2. The study focused on the safest and most reliable scenarios that could be implemented using existing equipment. Hardware modifications and new hardware proposals were identified, and their impact on the handling scenario has been evaluated. A conclusion was reached that by utilizing the existing facility hardware, these samples can be safely transported manually from the sample stations in CPP 601 to the RAL, and that additional hardware could facilitate the transportation process even further

  18. Procedure of trace element analysis in oyster tissues by using X-ray fluorescence

    International Nuclear Information System (INIS)

    Vo Thi Tuong Hanh; Dinh Thi Bich Lieu; Dinh Thien Lam and Nguyen Manh Hung

    2004-01-01

    The procedure of trace element analysis such as Ca, Mn, Fe, Zn, Cu, Pb in molluscs (oyster tissues) was established by using X-ray fluorescence techniques. The procedure was investigated from the sample collection, drying, ashing ratio to the analytical techniques by using Cd-109, detector Si (Li) and the peak processing MCAPLUS program was applied for this study. The procedure is based on direct comparison with certified concentrations of international standard reference SRM 1566b Oyster Tissue of National Institute of Standards and Technology, Department of commerce, United States of America for Ca, Mn, Fe, Zn, Cu and the Standard Addition Methods for Pb. The accuracy of the Standard Addition Methods was estimated by CRM281 Rye Grass of Community Bureau of Reference-BCR, European Commission. The results of 10 samples which were collected from several markets in Hanoi are shown. (author)

  19. Sampling and analysis plan for the consolidated sludge samples from the canisters and floor of the 105-K East basin

    International Nuclear Information System (INIS)

    BAKER, R.B.

    1999-01-01

    This Sampling and Analysis Plan (SAP) provides direction for sampling of fuel canister and floor Sludge from the K East Basin to complete the inventory of samples needed for Sludge treatment process testing. Sample volumes and sources consider recent reviews made by the Sludge treatment subproject. The representative samples will be characterized to the extent needed for the material to be used effectively for testing. Sampling equipment used allows drawing of large volume sludge samples and consolidation of sample material from a number of basin locations into one container. Once filled, the containers will be placed in a cask and transported to Hanford laboratories for recovery and evaluation. Included in the present SAP are the logic for sample location selection, laboratory analysis procedures required, and reporting needed to meet the Data Quality Objectives (DQOs) for this initiative

  20. Environmental sample accounting at the Savannah River Plant

    International Nuclear Information System (INIS)

    Zeigler, C.C.; Wood, M.B.

    1978-01-01

    At the Savannah River Plant Environmental Monitoring Laboratories, a computer-based systematic accounting method was developed to ensure that all scheduled samples are collected, processed through the laboratory, and counted without delay. The system employs an IBM 360/195 computer with a magnetic tape master file, an online disk file, and cathode ray tube (CRT) terminals. Scheduling and accounting are accomplished using computer-generated schedules, bottle labels, and output/ input cards. A printed card is issued for the collecting, analyzing, and counting of each scheduled sample. The card also contains information for the personnel who are to perform the work, e.g., sample location, aliquot to be processed, and procedure to be used. Manual entries are made on the card when each step in the process is completed. Additional pertinent data such as the reason a sample is not collected, the need for a nonstandard aliquot, and field measurement results are keypunched and then read into the computer files as required. The computer files are audited daily and summaries showing samples not processed in pre-established normal schedules are provided. The progress of sample analyses is readily determined at any time using the CRT terminal. Historic data are maintained on magnetic tape, and workload summaries showing the number of samples and number of determinations per month are issued. (author)

  1. Different Analytical Procedures for the Study of Organic Residues in Archeological Ceramic Samples with the Use of Gas Chromatography-mass Spectrometry.

    Science.gov (United States)

    Kałużna-Czaplińska, Joanna; Rosiak, Angelina; Kwapińska, Marzena; Kwapiński, Witold

    2016-01-01

    The analysis of the composition of organic residues present in pottery is an important source of information for historians and archeologists. Chemical characterization of the materials provides information on diets, habits, technologies, and original use of the vessels. This review presents the problem of analytical studies of archeological materials with a special emphasis on organic residues. Current methods used in the determination of different organic compounds in archeological ceramics are presented. Particular attention is paid to the procedures of analysis of archeological ceramic samples used before gas chromatography-mass spectrometry. Advantages and disadvantages of different extraction methods and application of proper quality assurance/quality control procedures are discussed.

  2. Storage method, drying processes and extraction procedures strongly affect the phenolic fraction of rosemary leaves: an HPLC/DAD/MS study.

    Science.gov (United States)

    Mulinacci, N; Innocenti, M; Bellumori, M; Giaccherini, C; Martini, V; Michelozzi, M

    2011-07-15

    The Rosmarinus officinalis L. is widely known for its numerous applications in the food field but also for the increasing interest in its pharmaceutical properties. Two groups of compounds are mainly responsible for the biological activities of the plant: the volatile fraction and the phenolic constituents. The latter group is mainly constituted by rosmarinic acid, by a flavonoidic fraction and by some diterpenoid compounds structurally derived from the carnosic acid. The aim of our work was to optimize the extractive and analytical procedure for the determination of all the phenolic constituents. Moreover the chemical stability of the main phenols, depending on the storage condition, the different drying procedures and the extraction solvent, have been evaluated. This method allowed to detect up to 29 different constituents at the same time in a relatively short time. The described procedure has the advantage to being able to detect and quantify several classes of compounds, among them numerous minor flavonoids, thus contributing to improving knowledge of the plant. The findings from this study have demonstrated that storing the raw fresh material in the freezer is not appropriate for rosemary, mainly due to the rapid disappearing of the rosmarinic acid during the freezing/thawing process. Regarding the flavonoidic fraction, consistent decrements, were highlighted in the dried samples at room temperature if compared with the fresh leaf. Rosmarinic acid, appeared very sensitive also to mild drying processes. The total diterpenoidic content undergoes to little changes when the leaves are freeze dried or frozen and limited losses are observed working on dried leaves at room temperature. Nevertheless it can be taken in account that this fraction is very sensitive to the water presence during the extraction that favors the conversion of carnosic acid toward it oxidized form carnosol. From our findings, it appear evident that when evaluating the phenolic content in

  3. In-process weld sampling during hot end welds of type W overpacks

    International Nuclear Information System (INIS)

    Barnes, G.A.

    1998-01-01

    Establish the criteria and process controls to be used in obtaining, testing, and evaluating in-process weld sample during the hot end welding of Type W Overpack capsules used to overpack CsCl capsules for storage at WESF

  4. Sampling method of environmental radioactivity monitoring

    International Nuclear Information System (INIS)

    1984-01-01

    This manual provides sampling methods of environmental samples of airborne dust, precipitated dust, precipitated water (rain or snow), fresh water, soil, river sediment or lake sediment, discharged water from a nuclear facility, grains, tea, milk, pasture grass, limnetic organisms, daily diet, index organisms, sea water, marine sediment, marine organisms, and that for tritium and radioiodine determination for radiation monitoring from radioactive fallout or radioactivity release by nuclear facilities. This manual aims at the presentation of standard sampling procedures for environmental radioactivity monitoring regardless of monitoring objectives, and shows preservation method of environmental samples acquired at the samplingpoint for radiation counting for those except human body. Sampling techniques adopted in this manual is decided by the criteria that they are suitable for routine monitoring and any special skillfulness is not necessary. Based on the above-mentioned principle, this manual presents outline and aims of sampling, sampling position or object, sampling quantity, apparatus, equipment or vessel for sampling, sampling location, sampling procedures, pretreatment and preparation procedures of a sample for radiation counting, necessary recording items for sampling and sample transportation procedures. Special attention is described in the chapter of tritium and radioiodine because these radionuclides might be lost by the above-mentioned sample preservation method for radiation counting of less volatile radionuclides than tritium or radioiodine. (Takagi, S.)

  5. Development of Process Automation in the Neutron Activation Analysis Facility in Malaysian Nuclear Agency

    International Nuclear Information System (INIS)

    Yussup, N.; Azman, A.; Ibrahim, M.M.; Rahman, N.A.A.; Che Sohashaari, S.; Atan, M.N.; Hamzah, M.A.; Mokhtar, M.; Khalid, M.A.; Salim, N.A.A.; Hamzah, M.S.

    2018-01-01

    Neutron Activation Analysis (NAA) has been established in Malaysian Nuclear Agency (Nuclear Malaysia) since 1980s. Most of the procedures established from sample registration to analysis are performed manually. These manual procedures carried out by the NAA laboratory personnel are time consuming and inefficient. Hence, system automation is developed in order to provide an effective method to replace redundant manual data entries and produce faster sample analysis and calculation process. This report explains NAA process in Nuclear Malaysia and describes the automation development in detail which includes sample registration software, automatic sample changer system which consists of hardware and software; and sample analysis software. (author)

  6. Microfabricated Devices for Sample Extraction, Concentrations, and Related Sample Processing Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Gang; Lin, Yuehe

    2006-12-01

    This is an invited book chapter. As with other analytical techniques, sample pretreatments, sample extraction, sample introduction, and related techniques are of extreme importance for micro-electro-mechanical systems (MEMS). Bio-MEMS devices and systems start with a sampling step. The biological sample then usually undergoes some kinds of sample preparation steps before the actual analysis. These steps may involve extracting the target sample from its matrix, removing interferences from the sample, derivatizing the sample to detectable species, or performing a sample preconcentration step. The integration of the components for sample pretreatment into microfluidic devices represents one of the remaining the bottle-neck towards achieving true miniaturized total analysis systems (?TAS). This chapter provides a thorough state-of-art of the developments in this field to date.

  7. The new Administrative Procedure and Administrative Process Law (Law 1.437 of 2011)

    OpenAIRE

    Expósito Vélez, Juan Carlos

    2011-01-01

    The new Administrative Procedure and Administrative Process Law (Law 1.437 of 2011) require a deep analysis, because it brings a new perception of old models of the Administrative Colombian Law: nullity, nullity and reestablishment of rights and the controversies relative to public contracts. El Nuevo Código de Procedimiento Administrativo y de lo Contencioso Administrativo (Ley 1.437 de 2.011) requiere de un análisis profundo, debido al nuevo alcance que trae a figuras tradicionales del ...

  8. Soil washing physical separations test procedure - 300-FF-1 operable unit

    Energy Technology Data Exchange (ETDEWEB)

    Belden, R.D.

    1993-10-08

    This procedure provides the operations approach, a field sampling plan, and laboratory procedures for a soil washing test to be conducted by Alternative Remedial Technologies, Inc. (ART) in the 300-FF-1 area at the Hanford site. The {open_quotes}Quality Assurance Project Plan for the Soil Washing Physical Separations Test, 300-FF-1 Operable Unit,{close_quotes} Hanford, Washington, Alternative Remedial Technologies, Inc., February 1994 (QAPP) is provided in a separate document that presents the procedural and organizational guidelines for this test. This document describes specifications, responsibilities, and general procedures to be followed to conduct physical separation soil treatability tests in the North Process Pond of the 300-FF-1 Operable Unit (OU) at the Hanford Site. These procedures are based on the {open_quotes}300-FF-1 Physical Separations CERCLA Treatability Test Plan, DOE/RL 92-2l,{close_quotes} (DOE-RL 1993).

  9. Soil washing physical separations test procedure - 300-FF-1 operable unit

    International Nuclear Information System (INIS)

    Belden, R.D.

    1993-01-01

    This procedure provides the operations approach, a field sampling plan, and laboratory procedures for a soil washing test to be conducted by Alternative Remedial Technologies, Inc. (ART) in the 300-FF-1 area at the Hanford site. The open-quotes Quality Assurance Project Plan for the Soil Washing Physical Separations Test, 300-FF-1 Operable Unit,close quotes Hanford, Washington, Alternative Remedial Technologies, Inc., February 1994 (QAPP) is provided in a separate document that presents the procedural and organizational guidelines for this test. This document describes specifications, responsibilities, and general procedures to be followed to conduct physical separation soil treatability tests in the North Process Pond of the 300-FF-1 Operable Unit (OU) at the Hanford Site. These procedures are based on the open-quotes 300-FF-1 Physical Separations CERCLA Treatability Test Plan, DOE/RL 92-2l,close quotes (DOE-RL 1993)

  10. Examination of the Triarchic Assessment Procedure for Inconsistent Responding in six non-English language samples.

    Science.gov (United States)

    Kelley, Shannon E; van Dongen, Josanne D M; Donnellan, M Brent; Edens, John F; Eisenbarth, Hedwig; Fossati, Andrea; Howner, Katarina; Somma, Antonella; Sörman, Karolina

    2018-05-01

    The Triarchic Assessment Procedure for Inconsistent Responding (TAPIR; Mowle et al., 2016) was recently developed to identify inattentiveness or comprehension difficulties that may compromise the validity of responses on the Triarchic Psychopathy Measure (TriPM; Patrick, 2010). The TAPIR initially was constructed and cross-validated using exclusively English-speaking participants from the United States; however, research using the TriPM has been increasingly conducted internationally, with numerous foreign language translations of the measure emerging. The present study examined the cross-language utility of the TAPIR in German, Dutch, Swedish, and Italian translations of the TriPM using 6 archival samples of community members, university students, forensic psychiatric inpatients, forensic detainees, and adolescents residing outside the United States (combined N = 5,404). Findings suggest that the TAPIR effectively detects careless responding across these 4 translated versions of the TriPM without the need for language-specific modifications. The TAPIR total score meaningfully discriminated genuine participant responses from both fully and partially randomly generated data in every sample, and demonstrated further utility in detecting fixed "all true" or "all false" response patterns. In addition, TAPIR scores were reliably associated with inconsistent responding scores from another psychopathy inventory. Specificity for a range of tentative cut scores for assessing profile validity was modestly reduced among our samples relative to rates previously obtained with the English version of the TriPM; however, overall the TAPIR appears to demonstrate satisfactory cross-language generalizability. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  11. Minimization of the blank values in the neutron activation analysis of biological samples considering the whole procedure

    International Nuclear Information System (INIS)

    Lux, F.; Bereznai, T.; Trebert Haeberlin, S.

    1987-01-01

    During the determination of trace element contents of animal tissue by neutron activation analysis in the course of structure-activity relationship studies on platinum containing cancer drugs and wound healing the authors tried to minimize the blank values that are caused by different sources of contamination during surgery, sampling and the activation analysis procedure. The following topics were investigated: abrasions from scalpels made of stainless steel, titanium or quartz, the type of surgery, the surface contaminations of the quartz ampoules, etc. The measures to be taken to reduce tha blank values are described. (author) 19 refs.; 4 tables

  12. New image-processing and noise-reduction software reduces radiation dose during complex endovascular procedures.

    Science.gov (United States)

    Kirkwood, Melissa L; Guild, Jeffrey B; Arbique, Gary M; Tsai, Shirling; Modrall, J Gregory; Anderson, Jon A; Rectenwald, John; Timaran, Carlos

    2016-11-01

    A new proprietary image-processing system known as AlluraClarity, developed by Philips Healthcare (Best, The Netherlands) for radiation-based interventional procedures, claims to lower radiation dose while preserving image quality using noise-reduction algorithms. This study determined whether the surgeon and patient radiation dose during complex endovascular procedures (CEPs) is decreased after the implementation of this new operating system. Radiation dose to operators, procedure type, reference air kerma, kerma area product, and patient body mass index were recorded during CEPs on two Philips Allura FD 20 fluoroscopy systems with and without Clarity. Operator dose during CEPs was measured using optically stimulable, luminescent nanoDot (Landauer Inc, Glenwood, Ill) detectors placed outside the lead apron at the left upper chest position. nanoDots were read using a microStar ii (Landauer Inc) medical dosimetry system. For the CEPs in the Clarity group, the radiation dose to surgeons was also measured by the DoseAware (Philips Healthcare) personal dosimetry system. Side-by-side measurements of DoseAware and nanoDots allowed for cross-calibration between systems. Operator effective dose was determined using a modified Niklason algorithm. To control for patient size and case complexity, the average fluoroscopy dose rate and the dose per radiographic frame were adjusted for body mass index differences and then compared between the groups with and without Clarity by procedure. Additional factors, for example, physician practice patterns, that may have affected operator dose were inferred by comparing the ratio of the operator dose to procedural kerma area product with and without Clarity. A one-sided Wilcoxon rank sum test was used to compare groups for radiation doses, reference air kermas, and operating practices for each procedure type. The analysis included 234 CEPs; 95 performed without Clarity and 139 with Clarity. Practice patterns of operators during

  13. Can an inadequate cervical cytology sample in ThinPrep be converted to a satisfactory sample by processing it with a SurePath preparation?

    Science.gov (United States)

    Sørbye, Sveinung Wergeland; Pedersen, Mette Kristin; Ekeberg, Bente; Williams, Merete E Johansen; Sauer, Torill; Chen, Ying

    2017-01-01

    The Norwegian Cervical Cancer Screening Program recommends screening every 3 years for women between 25 and 69 years of age. There is a large difference in the percentage of unsatisfactory samples between laboratories that use different brands of liquid-based cytology. We wished to examine if inadequate ThinPrep samples could be satisfactory by processing them with the SurePath protocol. A total of 187 inadequate ThinPrep specimens from the Department of Clinical Pathology at University Hospital of North Norway were sent to Akershus University Hospital for conversion to SurePath medium. Ninety-one (48.7%) were processed through the automated "gynecologic" application for cervix cytology samples, and 96 (51.3%) were processed with the "nongynecological" automatic program. Out of 187 samples that had been unsatisfactory by ThinPrep, 93 (49.7%) were satisfactory after being converted to SurePath. The rate of satisfactory cytology was 36.6% and 62.5% for samples run through the "gynecology" program and "nongynecology" program, respectively. Of the 93 samples that became satisfactory after conversion from ThinPrep to SurePath, 80 (86.0%) were screened as normal while 13 samples (14.0%) were given an abnormal diagnosis, which included 5 atypical squamous cells of undetermined significance, 5 low-grade squamous intraepithelial lesion, 2 atypical glandular cells not otherwise specified, and 1 atypical squamous cells cannot exclude high-grade squamous intraepithelial lesion. A total of 2.1% (4/187) of the women got a diagnosis of cervical intraepithelial neoplasia 2 or higher at a later follow-up. Converting cytology samples from ThinPrep to SurePath processing can reduce the number of unsatisfactory samples. The samples should be run through the "nongynecology" program to ensure an adequate number of cells.

  14. Systematic Procedure for Integrated Process Operation: Reverse Electro-Enhanced Dialysis (REED) during Lactic Acid Fermentation

    DEFF Research Database (Denmark)

    Prado Rubio, Oscar Andres; Jørgensen, Sten Bay; Jonsson, Gunnar Eigil

    2011-01-01

    The integration of lactic acid fermentation and Reverse Electro-Enhanced Dialysis (REED) is investigated based upon previously developed mathematical models. A goal driven process and operation design procedure is proposed and partially investigated. The conceptual analysis of the processes...... integration shows the need for an additional pH controller in the fermenten A PI controller is implemented and tested. The complete control structure for the integrated system consists of this PI controller in the fermenter plus a previously developed (Prado-Rubio et al., 2010) input resetting control...

  15. EML procedures manual

    International Nuclear Information System (INIS)

    Volchok, H.L.; de Planque, G.

    1982-01-01

    This manual contains the procedures that are used currently by the Environmental Measurements Laboratory of the US Department of Energy. In addition a number of analytical methods from other laboratories have been included. These were tested for reliability at the Battelle, Pacific Northwest Laboratory under contract with the Division of Biomedical and Environmental Research of the AEC. These methods are clearly distinguished. The manual is prepared in loose leaf form to facilitate revision of the procedures and inclusion of additional procedures or data sheets. Anyone receiving the manual through EML should receive this additional material automatically. The contents are as follows: (1) general; (2) sampling; (3) field measurements; (4) general analytical chemistry; (5) chemical procedures; (6) data section; (7) specifications

  16. Rapid filtration separation-based sample preparation method for Bacillus spores in powdery and environmental matrices.

    Science.gov (United States)

    Isabel, Sandra; Boissinot, Maurice; Charlebois, Isabelle; Fauvel, Chantal M; Shi, Lu-E; Lévesque, Julie-Christine; Paquin, Amélie T; Bastien, Martine; Stewart, Gale; Leblanc, Eric; Sato, Sachiko; Bergeron, Michel G

    2012-03-01

    Authorities frequently need to analyze suspicious powders and other samples for biothreat agents in order to assess environmental safety. Numerous nucleic acid detection technologies have been developed to detect and identify biowarfare agents in a timely fashion. The extraction of microbial nucleic acids from a wide variety of powdery and environmental samples to obtain a quality level adequate for these technologies still remains a technical challenge. We aimed to develop a rapid and versatile method of separating bacteria from these samples and then extracting their microbial DNA. Bacillus atrophaeus subsp. globigii was used as a simulant of Bacillus anthracis. We studied the effects of a broad variety of powdery and environmental samples on PCR detection and the steps required to alleviate their interference. With a benchmark DNA extraction procedure, 17 of the 23 samples investigated interfered with bacterial lysis and/or PCR-based detection. Therefore, we developed the dual-filter method for applied recovery of microbial particles from environmental and powdery samples (DARE). The DARE procedure allows the separation of bacteria from contaminating matrices that interfere with PCR detection. This procedure required only 2 min, while the DNA extraction process lasted 7 min, for a total of sample preparation procedure allowed the recovery of cleaned bacterial spores and relieved detection interference caused by a wide variety of samples. Our procedure was easily completed in a laboratory facility and is amenable to field application and automation.

  17. Microwave-assisted extraction and mild saponification for determination of organochlorine pesticides in oyster samples.

    Science.gov (United States)

    Carro, N; García, I; Ignacio, M-C; Llompart, M; Yebra, M-C; Mouteira, A

    2002-10-01

    A sample-preparation procedure (extraction and saponification) using microwave energy is proposed for determination of organochlorine pesticides in oyster samples. A Plackett-Burman factorial design has been used to optimize the microwave-assisted extraction and mild saponification on a freeze dried sample spiked with a mixture of aldrin, endrin, dieldrin, heptachlor, heptachorepoxide, isodrin, transnonachlor, p, p'-DDE, and p, p'-DDD. Six variables: solvent volume, extraction time, extraction temperature, amount of acetone (%) in the extractant solvent, amount of sample, and volume of NaOH solution were considered in the optimization process. The results show that the amount of sample is statistically significant for dieldrin, aldrin, p, p'-DDE, heptachlor, and transnonachlor and solvent volume for dieldrin, aldrin, and p, p'-DDE. The volume of NaOH solution is statistically significant for aldrin and p, p'-DDE only. Extraction temperature and extraction time seem to be the main factors determining the efficiency of extraction process for isodrin and p, p'-DDE, respectively. The optimized procedure was compared with conventional Soxhlet extraction.

  18. A novel solid phase extraction procedure on Amberlite XAD-1180 for speciation of Cr(III), Cr(VI) and total chromium in environmental and pharmaceutical samples

    International Nuclear Information System (INIS)

    Narin, Ibrahim; Kars, Ayse; Soylak, Mustafa

    2008-01-01

    Due to the toxicity of chromium, species depend on their chemical properties and bioavailabilities, speciation of chromium is very important in environmental samples. A speciation procedure for chromium(III), chromium(VI) and total chromium in environmental samples is presented in this work, prior to flame atomic absorption spectrometric determination of chromium. The procedure is based on the adsorption of Cr(III)-diphenylcarbazone complex on Amberlite XAD-1180 resin. After oxidation of Cr(III), the developed solid phase extraction system was applied to determinate the total chromium. Cr(III) was calculated as the difference between the total Cr content and the Cr(VI) content. The analytical conditions for the quantitative recoveries of Cr(VI) on Amberlite XAD-1180 resin were investigated. The effects of some alkaline, earth alkaline, metal ions and also some anions were also examined. Preconcentration factor was found to be 75. The detection limits (LOD) based on three times sigma of the blank (N: 21) for Cr(VI) and total chromium were 7.7 and 8.6 μg/L, respectively. Satisfactory results for the analysis of total chromium in the stream sediment (GBW7310) certified reference material for the validation of the presented method was obtained. The procedure was applied to food, water and pharmaceutical samples successfully

  19. Order–disorder–reorder process in thermally treated dolomite samples

    DEFF Research Database (Denmark)

    Zucchini, Azzurra; Comodi, Paola; Katerinopoulou, Anna

    2012-01-01

    A combined powder and single-crystal X-ray diffraction analysis of dolomite [CaMg(CO3)2] heated to 1,200oC at 3 GPa was made to study the order–disorder–reorder process. The order/disorder transition is inferred to start below 1,100oC, and complete disorder is attained at approximately 1,200o......C. Twinned crystals characterized by high internal order were found in samples annealed over 1,100oC, and their fraction was found to increase with temperature. Evidences of twinning domains combined with probable remaining disordered portions of the structure imply that reordering processes occur during...

  20. Direct analysis of biological samples by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Lue M, Marco P.; Hernandez-Caraballo, Edwin A.

    2004-01-01

    The technique of total reflection X-ray fluorescence (TXRF) is well suited for the direct analysis of biological samples due to the low matrix interferences and simultaneous multi-element nature. Nevertheless, biological organic samples are frequently analysed after digestion procedures. The direct determination of analytes requires shorter analysis time, low reactive consumption and simplifies the whole analysis process. On the other hand, the biological/clinical samples are often available in minimal amounts and routine studies require the analysis of large number of samples. To overcome the difficulties associated with the analysis of organic samples, particularly of solid ones, different procedures of sample preparation and calibration to approach the direct analysis have been evaluated: (1) slurry sampling, (2) Compton peak standardization, (3) in situ microwave digestion, (4) in situ chemical modification and (5) direct analysis with internal standardization. Examples of analytical methods developed by our research group are discussed. Some of them have not been previously published, illustrating alternative strategies for coping with various problems that may be encountered in the direct analysis by total reflection X-ray fluorescence spectrometry

  1. Chain sampling plan (ChSP-1) for desired acceptable quality level (AQL) and limiting quality level (LQL)

    Science.gov (United States)

    Raju, C.; Vidya, R.

    2017-11-01

    Chain Sampling Plan is widely used whenever a small sample attributes plan is required to be used for situations involving destructive products coming out of continuous production process [1, 2]. This paper presents a procedure for the construction and selection of a ChSP-1 by attributes inspection based on membership functions [3]. A procedure using search technique is developed for obtaining the parameters of single sampling plan for a given set of AQL and LQL values. A sample of tables providing ChSP-1 plans for various combinations of AQL and LQL values are presented [4].

  2. A fast network solution by the decoupled procedure during short-term dynamic processes in power systems

    Energy Technology Data Exchange (ETDEWEB)

    Popovic, D P; Stefanovic, M D [Nikola Tesla Inst., Belgrade (YU). Power System Dept.

    1990-01-01

    A simple, fast and reliable decoupled procedure for solving the network problems during short-term dynamic processes in power systems is presented. It is based on the Newton-Raphson method applied to the power balance equations, which include the effects of generator saliency and non-impedance loads, with further modifications resulting from the physical properties of the phenomena under study. The good convergence characteristics of the developed procedure are demonstrated, and a comparison is made with the traditional method based on the current equation and the triangularized admittance matrix, using the example of stability analysis of the Yugoslav power grid. (author).

  3. 40 CFR 63.1104 - Process vents from continuous unit operations: applicability assessment procedures and methods.

    Science.gov (United States)

    2010-07-01

    ...) Necessitating that the owner or operator make product in excess of demand. (e) TOC or Organic HAP concentration....306×10 −2 a Use according to procedures outlined in this section. MJ/scm = Mega Joules per standard cubic meter. scm/min = Standard cubic meters per minute. (2) Nonhalogenated process vents. The owner or...

  4. Welding qualification procedure for fuel rods tubes of Zr-Sn alloys by the TIG automatic process

    International Nuclear Information System (INIS)

    1984-11-01

    It is presented the requirements to be used in the Welding qualification procedure for tubes of Zr-Sn alloys, specified in the ASTM B353 regulatory guide, used in the fabrication of fuel rods PWR reactors by the automatic TIG process. (E.G.) [pt

  5. A Guide for Developing Standard Operating Job Procedures for the Screening & Grinding Process Wastewater Treatment Facility. SOJP No. 1.

    Science.gov (United States)

    Deal, Gerald A.; Montgomery, James A.

    This guide describes standard operating job procedures for the screening and grinding process of wastewater treatment facilities. The objective of this process is the removal of coarse materials from the raw waste stream for the protection of subsequent equipment and processes. The guide gives step-by-step instructions for safety inspection,…

  6. Processes and Procedures for Application of CFD to Nuclear Reactor Safety Analysis

    International Nuclear Information System (INIS)

    Richard W. Johnson; Richard R. Schultz; Patrick J. Roache; Ismail B. Celik; William D. Pointer; Yassin A. Hassan

    2006-01-01

    of the flow and energy transport as applied to nuclear reactor safety. However, it is expected that these practices and procedures will require updating from time to time as research and development affect them or replace them with better procedures. The practices and procedures are categorized into five groups. These are: (1) Code Verification; (2) Code and Calculation Documentation; (3) Reduction of Numerical Error; (4) Quantification of Numerical Uncertainty (Calculation Verification); and (5) Calculation Validation. These five categories have been identified from procedures currently required of CFD simulations such as those required for publication of a paper in the ASME Journal of Fluids Engineering and from the literature such as Roache [1998]. Code verification refers to the demonstration that the equations of fluid and energy transport have been correctly coded in the CFD code. Code and calculation documentation simply means that the equations and their discretizations, etc., and boundary and initial conditions used to pose the fluid flow problem are fully described in available documentation. Reduction of numerical error refers to practices and procedures to lower numerical errors to negligible or very low levels as is reasonably possible (such as avoiding use of first-order discretizations). The quantification of numerical uncertainty is also known as calculation verification. This means that estimates are made of numerical error to allow the characterization of the numerical results with a certain confidence level. Numerical error in this case does not include error due to models such as turbulence models. Calculation validation is the process of comparing simulation results to experimental data to demonstrate level of agreement. Validation does include the effects of modeling errors as well as numerical and experimental errors. A key issue in the validation process of numerical results is the existence of appropriate experimental data to use for

  7. Recent results of the investigation of a micro-fluidic sampling chip and sampling system for hot cell aqueous processing streams

    International Nuclear Information System (INIS)

    Tripp, J.; Smith, T.; Law, J.

    2013-01-01

    A Fuel Cycle Research and Development project has investigated an innovative sampling method that could evolve into the next generation sampling and analysis system for metallic elements present in aqueous processing streams. Initially sampling technologies were evaluated and micro-fluidic sampling chip technology was selected and tested. A conceptual design for a fully automated microcapillary-based system was completed and a robotic automated sampling system was fabricated. The mechanical and sampling operation of the completed sampling system was investigated. Different sampling volumes have been tested. It appears that the 10 μl volume has produced data that had much smaller relative standard deviations than the 2 μl volume. In addition, the production of a less expensive, mass produced sampling chip was investigated to avoid chip reuse thus increasing sampling reproducibility/accuracy. The micro-fluidic-based robotic sampling system's mechanical elements were tested to ensure analytical reproducibility and the optimum robotic handling of micro-fluidic sampling chips. (authors)

  8. Sampling methodology and PCB analysis

    International Nuclear Information System (INIS)

    Dominelli, N.

    1995-01-01

    As a class of compounds PCBs are extremely stable and resist chemical and biological decomposition. Diluted solutions exposed to a range of environmental conditions will undergo some preferential degradation and the resulting mixture may differ considerably from the original PCB used as insulating fluid in electrical equipment. The structure of mixtures of PCBs (synthetic compounds prepared by direct chlorination of biphenyl with chlorine gas) is extremely complex and presents a formidable analytical problem, further complicated by the presence of PCBs as contaminants in oils to soils to water. This paper provides some guidance into sampling and analytical procedures; it also points out various potential problems encountered during these processes. The guidelines provided deal with sample collection, storage and handling, sample stability, laboratory analysis (usually gas chromatography), determination of PCB concentration, calculation of total PCB content, and quality assurance. 1 fig

  9. Theory of sampling and its application in tissue based diagnosis

    Directory of Open Access Journals (Sweden)

    Kayser Gian

    2009-02-01

    Full Text Available Abstract Background A general theory of sampling and its application in tissue based diagnosis is presented. Sampling is defined as extraction of information from certain limited spaces and its transformation into a statement or measure that is valid for the entire (reference space. The procedure should be reproducible in time and space, i.e. give the same results when applied under similar circumstances. Sampling includes two different aspects, the procedure of sample selection and the efficiency of its performance. The practical performance of sample selection focuses on search for localization of specific compartments within the basic space, and search for presence of specific compartments. Methods When a sampling procedure is applied in diagnostic processes two different procedures can be distinguished: I the evaluation of a diagnostic significance of a certain object, which is the probability that the object can be grouped into a certain diagnosis, and II the probability to detect these basic units. Sampling can be performed without or with external knowledge, such as size of searched objects, neighbourhood conditions, spatial distribution of objects, etc. If the sample size is much larger than the object size, the application of a translation invariant transformation results in Kriege's formula, which is widely used in search for ores. Usually, sampling is performed in a series of area (space selections of identical size. The size can be defined in relation to the reference space or according to interspatial relationship. The first method is called random sampling, the second stratified sampling. Results Random sampling does not require knowledge about the reference space, and is used to estimate the number and size of objects. Estimated features include area (volume fraction, numerical, boundary and surface densities. Stratified sampling requires the knowledge of objects (and their features and evaluates spatial features in relation to

  10. Analysis procedure for americium in environmental samples

    International Nuclear Information System (INIS)

    Holloway, R.W.; Hayes, D.W.

    1982-01-01

    Several methods for the analysis of 241 Am in environmental samples were evaluated and a preferred method was selected. This method was modified and used to determine the 241 Am content in sediments, biota, and water. The advantages and limitations of the method are discussed. The method is also suitable for 244 Cm analysis

  11. The principles, procedures and pitfalls in identifying archaeological and historical wood samples.

    Science.gov (United States)

    Cartwright, Caroline R

    2015-07-01

    The science of wood anatomy has evolved in recent decades to add archaeological and historical wood to its repertoire of documenting and characterizing modern and fossil woods. The increasing use of online wood anatomy databases and atlases has fostered the adoption of an international consensus regarding terminology, largely through the work of the International Association of Wood Anatomists (IAWA). This review presents an overview for the general reader of the current state of principles and procedures involved in the study of the wood anatomy of archaeological and historical specimens, some of which may be preserved through charring, waterlogging, desiccation or mineral replacement. By means of selected case studies, the review evaluates to what extent varying preservation of wood anatomical characteristics limits the level of identification to taxon. It assesses the role played by increasingly accessible scanning electron microscopes and complex optical microscopes, and whether these, on the one hand, provide exceptional opportunities for high-quality imaging and analysis of difficult samples, but, on the other hand, might be misleading the novice into thinking that advanced technology can be a substitute for specialized botanical training in wood anatomy. © The Author 2015. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Development of an analytical procedure for plutonium in the concentration range of femtogram/gram and its application to environmental samples

    International Nuclear Information System (INIS)

    Schuettelkopf, H.

    1981-09-01

    To study the behaviour of plutonium in the environment and to measure plutonium in the vicinity of nuclear facilities, a quick, sensitive analytical method is required which can be applied to all sample materials found in the environment. For a sediment contaminated with plutonium a boiling out method using first HNO 3 /HF and subsequently HNO 3 /Al(NO 3 ) 3 was found to be successful. The leaching solution was then extracted by TOPO and the plutonium backextracted by ascorbic acid/HCl. Some different purification steps and finally electroplating using ammonium oxalate led to an optimum sample for α- spectroscopic determination of plutonium. An analytical method was worked out for plutonium which can be applied to all materials found in the environment. The sample size is 100 g but it might also be much greater. The average chemical yield is 70 and 80%. The detection limit for soil samples is 0.1 fCi/g and for plant samples 0.5 fCi/g. One technician can perform eight analyses per working day. The analytical procedure was applied to a large number of environmental samples and the results of these analyses are indicated. (orig./RB) [de

  13. Microbial ecology laboratory procedures manual NASA/MSFC

    Science.gov (United States)

    Huff, Timothy L.

    1990-01-01

    An essential part of the efficient operation of any microbiology laboratory involved in sample analysis is a standard procedures manual. The purpose of this manual is to provide concise and well defined instructions on routine technical procedures involving sample analysis and methods for monitoring and maintaining quality control within the laboratory. Of equal importance is the safe operation of the laboratory. This manual outlines detailed procedures to be followed in the microbial ecology laboratory to assure safety, analytical control, and validity of results.

  14. Role of food safety in procedures adopted for the purchase of minimally processed and fresh vegetables by foodservices

    Directory of Open Access Journals (Sweden)

    Kátia Regina Martini Rodrigues

    2010-12-01

    Full Text Available This research was designed to analyze whether the procedures adopted by foodservice establishments for the purchase of minimally processed and fresh vegetables favor the acquisition of safe products. This research investigated the purchasing policies of such establishments, whether self-managed or administered by foodservice contractors, in the municipality of Campinas and its outlying districts. A random sample of thirty-nine establishments participated in the research. The instruments for data collection were pre-tested, and the actual interviews were conducted by trained personnel. Comparative analyses were made using various statistical tests. All of the participating establishments purchase fresh vegetables, although only six of them use minimally processed ones. For most of the establishments, price is at least one of the most important criteria for the selection of a supplier, and they do not normally monitor the safety of the fresh products purchased (51.3%, nor do they make regular technical visits to guarantee quality (46.2%; moreover, most do not carry out a supplier development program. It is suggested that routine technical visits to suppliers should be adopted, as well as the creation of courses, such as those dealing with the safety of vegetables and supplier development, to be offered to foodservices.

  15. Recovery of extracellular vesicles from human breast milk is influenced by sample collection and vesicle isolation procedures

    Directory of Open Access Journals (Sweden)

    Marijke I. Zonneveld

    2014-08-01

    Full Text Available Extracellular vesicles (EV in breast milk carry immune relevant proteins and could play an important role in the instruction of the neonatal immune system. To further analyze these EV and to elucidate their function it is important that native populations of EV can be recovered from (stored breast milk samples in a reproducible fashion. However, the impact of isolation and storage procedures on recovery of breast milk EV has remained underexposed. Here, we aimed to define parameters important for EV recovery from fresh and stored breast milk. To compare various protocols across different donors, breast milk was spiked with a well-defined murine EV population. We found that centrifugation of EV down into density gradients largely improved density-based separation and isolation of EV, compared to floatation up into gradients after high-force pelleting of EV. Using cryo-electron microscopy, we identified different subpopulations of human breast milk EV and a not previously described population of lipid tubules. Additionally, the impact of cold storage on breast milk EV was investigated. We determined that storing unprocessed breast milk at −80°C or 4°C caused death of cells present in breast milk, leading to contamination of the breast milk EV population with storage-induced EV. Here, an alternative method is proposed to store breast milk samples for EV analysis at later time points. The proposed adaptations to the breast milk storage and EV isolation procedures can be applied for EV-based biomarker profiling of breast milk and functional analysis of the role of breast milk EV in the development of the neonatal immune system.

  16. Advances in modern sample preparation techniques using microwaves assisted chemistry for metal species determination (W1)

    International Nuclear Information System (INIS)

    Ponard, O.F.X.

    2002-01-01

    Full text: Sample preparation has long been the bottleneck of environmental analysis for both total and species specific analysis. Digestion, extraction and preparation of the analytes are relying on a series of chemical reactions. The introduction of microwave assisted sample preparation has first been viewed as a mean to accelerate the kinetics of digestion of the matrix for total elements and fast samples preparation procedures. However, the extensive development and success of microwave digestion procedures in total elemental analysis has now allowed to have a larger insight of the perspectives offered by this technique. Microwave technologies now offer to have a precise control of the temperature and indirectly control the reaction kinetics taking place during the sample preparation procedures. Microwave assisted chemistry permits to perform simultaneously the fundamental steps required for metal species extraction and derivatization. The number of sample preparation steps used for organotin or organomercury species have been reduced to one and the total time of sample preparation brought down for a few hours to some minutes. Further, the developments of GC/ICP/MS techniques allow to routinely use speciated isotopic dilution methods has internal probe of the chemical reactions. These new approaches allow us to use the addition of the labeled species for isotopic dilution as a mean to evaluate and follow the chemical processes taking place during the extraction procedure. These procedures will help us to understand and check for the stability of the analytes during the chemistry of the sample preparation procedure and bring some insights of the chemistry taking place during the extraction. Understanding the different mechanisms involved in the sample preparation steps will allow us in return to further improve all theses procedures and bring us to the horizon of 'on-line sample preparation and detection'. (author)

  17. The state of the art of the impact of sampling uncertainty on measurement uncertainty

    Science.gov (United States)

    Leite, V. J.; Oliveira, E. C.

    2018-03-01

    The measurement uncertainty is a parameter that marks the reliability and can be divided into two large groups: sampling and analytical variations. Analytical uncertainty is a controlled process, performed in the laboratory. The same does not occur with the sampling uncertainty, which, because it faces several obstacles and there is no clarity on how to perform the procedures, has been neglected, although it is admittedly indispensable to the measurement process. This paper aims at describing the state of the art of sampling uncertainty and at assessing its relevance to measurement uncertainty.

  18. Random sampling of evolution time space and Fourier transform processing

    International Nuclear Information System (INIS)

    Kazimierczuk, Krzysztof; Zawadzka, Anna; Kozminski, Wiktor; Zhukov, Igor

    2006-01-01

    Application of Fourier Transform for processing 3D NMR spectra with random sampling of evolution time space is presented. The 2D FT is calculated for pairs of frequencies, instead of conventional sequence of one-dimensional transforms. Signal to noise ratios and linewidths for different random distributions were investigated by simulations and experiments. The experimental examples include 3D HNCA, HNCACB and 15 N-edited NOESY-HSQC spectra of 13 C 15 N labeled ubiquitin sample. Obtained results revealed general applicability of proposed method and the significant improvement of resolution in comparison with conventional spectra recorded in the same time

  19. A Pipeline for Large Data Processing Using Regular Sampling for Unstructured Grids

    Energy Technology Data Exchange (ETDEWEB)

    Berres, Anne Sabine [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Adhinarayanan, Vignesh [Virginia Polytechnic Inst. and State Univ. (Virginia Tech), Blacksburg, VA (United States); Turton, Terece [Univ. of Texas, Austin, TX (United States); Feng, Wu [Virginia Polytechnic Inst. and State Univ. (Virginia Tech), Blacksburg, VA (United States); Rogers, David Honegger [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-12

    Large simulation data requires a lot of time and computational resources to compute, store, analyze, visualize, and run user studies. Today, the largest cost of a supercomputer is not hardware but maintenance, in particular energy consumption. Our goal is to balance energy consumption and cognitive value of visualizations of resulting data. This requires us to go through the entire processing pipeline, from simulation to user studies. To reduce the amount of resources, data can be sampled or compressed. While this adds more computation time, the computational overhead is negligible compared to the simulation time. We built a processing pipeline at the example of regular sampling. The reasons for this choice are two-fold: using a simple example reduces unnecessary complexity as we know what to expect from the results. Furthermore, it provides a good baseline for future, more elaborate sampling methods. We measured time and energy for each test we did, and we conducted user studies in Amazon Mechanical Turk (AMT) for a range of different results we produced through sampling.

  20. Operability test procedure for 211BA flow proportional sampler

    International Nuclear Information System (INIS)

    Weissenfels, R.D.

    1994-01-01

    The purpose of this operability test procedure (OTP) is to verify the 211-BA flow proportional sampler system and components function correctly as intended by design. System test will include the sampling system, all associated instrumentation, and Facility Process Monitor and Control System (FPMCS). The combined chemical sewer stream from B Plant flows through sump 211BA-SMP-01 located in 211-BA and is continuously monitored for gamma and beta radiation and pH. 211-BA has been upgraded to include a flow proportional sampler. A specified sample volume will be withdrawn at programmed intervals from the 211BA sump and deposited in a 19 liter plastic carboy. The sampler will be programmed per the vendor installation and operations manual by B Plant instrument maintenance personnel. Samples will be taken during five consecutive sample cycles with the sample volumes and sample frequencies recorded for comparison purposes. Additional tests related to the sampler include the alarm circuitry for loss of power and failure to obtain sample

  1. Computer assisted procedure maintenance

    International Nuclear Information System (INIS)

    Bisio, R.; Hulsund, J. E.; Nilsen, S.

    2004-04-01

    The maintenance of operating procedures in a NPP is a tedious and complicated task. Through the whole life cycle of the procedures they will be dynamic, 'living' documents. Several aspects of the procedure must be considered in a revision process. Pertinent details and attributes of the procedure must be checked. An organizational structure must be created and responsibilities allotted for drafting, revising, reviewing and publishing procedures. Available powerful computer technology provides solutions within document management and computerisation of procedures. These solutions can also support the maintenance of procedures. Not all parts of the procedure life cycle are equally amenable to computerized support. This report looks at the procedure life cycle in todays NPPs and discusses the possibilities associated with introduction of computer technology to assist the maintenance of procedures. (Author)

  2. Study on infrasonic characteristics of coal samples in failure process under uniaxial loading

    Directory of Open Access Journals (Sweden)

    Bing Jia

    Full Text Available To study the precursory failure infrasonic characteristics of coal samples, coal rock stress loading system and infrasonic wave acquisition system were adopted, and infrasonic tests in uniaxial loading process were made for the coal samples in the studied area. Wavelet filtering, fast Fourier transform, and relative infrasonic energy methods were used to analyze the characteristics of the infrasonic waves in the loading process, including time domain characteristics, and relative energy. The analysis results demonstrated that the frequencies of the infrasonic signals in the loading process mainly distribute within 5–10 Hz, which are significantly different from noise signals. The changes of the infrasonic signals show clear periodic characters in time domain. Meanwhile, the relative energy changes of the infrasonic wave also show periodic characters, which are divided into two stages by the yield limit of coal samples, and are clear and easy to be recognized, so that they can be used as the precursory characteristics for recognizing coal sample failures. Moreover, the infrasonic waves generated by coal samples have low frequency and low attenuation, which can be collected without coupling and transmitted in long distance. This study provides an important support for the further in-situ prediction of coal rock failures. Keywords: Infrasound, Relative energy, Time-frequency analysis, Failure prediction, Identification feature

  3. How can usability measurement affect the re-engineering process of clinical software procedures?

    Science.gov (United States)

    Terazzi, A; Giordano, A; Minuco, G

    1998-01-01

    As a consequence of the dramatic improvements achieved in information technology standards in terms of single hardware and software components, efforts in the evaluation processes have been focused on the assessment of critical human factors, such as work-flow organisation, man-machine interaction and, in general, quality of use, or usability. This trend is particularly valid when applied to medical informatics, since the human component is the basis of the information processing system in health care context. With the aim to establish an action-research project on the evaluation and assessment of clinical software procedures which constitute an integrated hospital information system, the authors adopted this strategy and considered the measurement of perceived usability as one of the main goals of the project itself: the paper reports the results of this experience.

  4. Procedural Due Process for Students at Public Colleges and Universities.

    Science.gov (United States)

    Golden, Edward J.

    1982-01-01

    Reports the findings of a study to determine what procedural protections are afforded students at public colleges and universities who are faced with disciplinary or academic dismissal. The data are from 62 of the 85 public postsecondary institutions asked to provide published procedural guidelines. (Author/MLF)

  5. A microscale protein NMR sample screening pipeline

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Paolo; Swapna, G. V. T.; Huang, Yuanpeng J.; Aramini, James M. [State University of New Jersey, Center for Advanced Biotechnology and Medicine, Department of Molecular Biology and Biochemistry, Rutgers (United States); Anklin, Clemens [Bruker Biospin Corporation (United States); Conover, Kenith; Hamilton, Keith; Xiao, Rong; Acton, Thomas B.; Ertekin, Asli; Everett, John K.; Montelione, Gaetano T., E-mail: guy@cabm.rutgers.ed [State University of New Jersey, Center for Advanced Biotechnology and Medicine, Department of Molecular Biology and Biochemistry, Rutgers (United States)

    2010-01-15

    As part of efforts to develop improved methods for NMR protein sample preparation and structure determination, the Northeast Structural Genomics Consortium (NESG) has implemented an NMR screening pipeline for protein target selection, construct optimization, and buffer optimization, incorporating efficient microscale NMR screening of proteins using a micro-cryoprobe. The process is feasible because the newest generation probe requires only small amounts of protein, typically 30-200 {mu}g in 8-35 {mu}l volume. Extensive automation has been made possible by the combination of database tools, mechanization of key process steps, and the use of a micro-cryoprobe that gives excellent data while requiring little optimization and manual setup. In this perspective, we describe the overall process used by the NESG for screening NMR samples as part of a sample optimization process, assessing optimal construct design and solution conditions, as well as for determining protein rotational correlation times in order to assess protein oligomerization states. Database infrastructure has been developed to allow for flexible implementation of new screening protocols and harvesting of the resulting output. The NESG micro NMR screening pipeline has also been used for detergent screening of membrane proteins. Descriptions of the individual steps in the NESG NMR sample design, production, and screening pipeline are presented in the format of a standard operating procedure.

  6. A new procedure for making TEM specimens of superconductor devices

    International Nuclear Information System (INIS)

    Huang, Y.; Merkle, K.L.

    1997-04-01

    A new procedure is developed for making TEM specimens of thin film devices. In this procedure the sample is flatly polished to an overall ion-mill-ready thickness so that any point in the 2-D sample pane can be thinned to an electron-transparent thickness by subsequent ion-milling. Using this procedure, small regions of interest can be easily reached in both cross-section and plan-view samples. This is especially useful in device studies. Applications of this procedure to the study of superconductor devices yield good results. This procedure, using commercially available equipment and relatively cheap materials, is simple and easy to realize

  7. Evaluation of some procedures relevant to the determination of trace elemental components in biological materials by destructive neutron activation analysis

    International Nuclear Information System (INIS)

    Berry, D.L.

    1979-01-01

    The development of a simplified procedure for the analysis of biological materials by destructive neutron activation analysis (DNAA) is described. The sample manipulations preceding gamma ray assay were investigated as five specific stages of processing: (1) pre-irradiation treatment; (2) sample irradiation; (3) removal of the organic matrix; (4) removal of interfering radioactivities; and (5) concentration and separation of analyte activities. Each stage was evaluated with respect to susceptibility to sample contamination, loss of trace elemental components, and compatibility with other operations in the overall DNAA procedures. A complete DNAA procedure was proposed and evaluated for the analysis of standard bovine liver and blood samples. The DNAA system was effective for the determination of As, Cu, Fe, Hg, Mo, Rb, Sb, Se, and Zn without yield determinations and with a minimum turn-around time of approximately 3 days

  8. Evaluation of some procedures relevant to the determination of trace elemental components in biological materials by destructive neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Berry, D.L.

    1979-01-01

    The development of a simplified procedure for the analysis of biological materials by destructive neutron activation analysis (DNAA) is described. The sample manipulations preceding gamma ray assay were investigated as five specific stages of processing: (1) pre-irradiation treatment; (2) sample irradiation; (3) removal of the organic matrix; (4) removal of interfering radioactivities; and (5) concentration and separation of analyte activities. Each stage was evaluated with respect to susceptibility to sample contamination, loss of trace elemental components, and compatibility with other operations in the overall DNAA procedures. A complete DNAA procedure was proposed and evaluated for the analysis of standard bovine liver and blood samples. The DNAA system was effective for the determination of As, Cu, Fe, Hg, Mo, Rb, Sb, Se, and Zn without yield determinations and with a minimum turn-around time of approximately 3 days.

  9. Determination of thiobencarb in water samples by gas chromatography using a homogeneous liquid-liquid microextraction via flotation assistance procedure

    Directory of Open Access Journals (Sweden)

    H.A. Mashayekhi

    2013-09-01

    Full Text Available Homogeneous liquid-liquid microextraction via flotation assistance (HLLME-FA coupled with gas chromatography-flame ionization detection (GC-FID was applied for the extraction and determination of thiobencarb in water samples. In this study, a special extraction cell was designed to facilitate collection of the low-density solvent extraction. No centrifugation was required in this procedure. The water sample solution was added into the extraction cell which contained an appropriate mixture of toluene (as an extraction solvent and acetone (as a homogeneous solvent. By using air flotation, the organic solvent was collected at the conical part of the designed cell. The effect of the different parameters on the efficiency of extraction such as type and volume of extraction and homogeneous solvents, ionic strength and extraction time were studied and optimized. Under the optimal conditions, linearity of the method was in the range of 1.0-200 µg L-1. The relative standard deviations in the real samples varied from 7.8-11.7 % (n = 3. The proposed method was successfully applied to analysis of thiobencarb in the water samples and satisfactory results were obtained.DOI: http://dx.doi.org/10.4314/bcse.v27i3.4

  10. Manure sampling procedures and nutrient estimation by the hydrometer method for gestation pigs.

    Science.gov (United States)

    Zhu, Jun; Ndegwa, Pius M; Zhang, Zhijian

    2004-05-01

    Three manure agitation procedures were examined in this study (vertical mixing, horizontal mixing, and no mixing) to determine the efficacy of producing a representative manure sample. The total solids content for manure from gestation pigs was found to be well correlated with the total nitrogen (TN) and total phosphorus (TP) concentrations in the manure, with highly significant correlation coefficients of 0.988 and 0.994, respectively. Linear correlations were observed between the TN and TP contents and the manure specific gravity (correlation coefficients: 0.991 and 0.987, respectively). Therefore, it may be inferred that the nutrients in pig manure can be estimated with reasonable accuracy by measuring the liquid manure specific gravity. A rapid testing method for manure nutrient contents (TN and TP) using a soil hydrometer was also evaluated. The results showed that the estimating error increased from +/-10% to +/-30% with the decrease in TN (from 1000 to 100 ppm) and TP (from 700 to 50 ppm) concentrations in the manure. Data also showed that the hydrometer readings had to be taken within 10 s after mixing to avoid reading drift in specific gravity due to the settling of manure solids.

  11. Neutron-activation analysis of routine mineral-processing samples

    International Nuclear Information System (INIS)

    Watterson, J.; Eddy, B.; Pearton, D.

    1974-01-01

    Instrumental neutron-activation analysis was applied to a suite of typical mineral-processing samples to establish which elements can be rapidly determined in them by this technique. A total of 35 elements can be determined with precisions (from the counting statistics) ranging from better than 1 per cent to approximately 20 per cent. The elements that can be determined have been tabulated together with the experimental conditions, the precision from the counting statistics, and the estimated number of analyses possible per day. With an automated system, this number can be as high as 150 in the most favourable cases [af

  12. Pippi — Painless parsing, post-processing and plotting of posterior and likelihood samples

    Science.gov (United States)

    Scott, Pat

    2012-11-01

    Interpreting samples from likelihood or posterior probability density functions is rarely as straightforward as it seems it should be. Producing publication-quality graphics of these distributions is often similarly painful. In this short note I describe pippi, a simple, publicly available package for parsing and post-processing such samples, as well as generating high-quality PDF graphics of the results. Pippi is easily and extensively configurable and customisable, both in its options for parsing and post-processing samples, and in the visual aspects of the figures it produces. I illustrate some of these using an existing supersymmetric global fit, performed in the context of a gamma-ray search for dark matter. Pippi can be downloaded and followed at http://github.com/patscott/pippi.

  13. A novel procedure for Rubidium separation and its isotope measurements on geological samples by MC-ICP-MS

    Science.gov (United States)

    Ma, J.; Zhang, Z.; Wei, G.; Zhang, L.

    2017-12-01

    A method including a novel column Rb separation procedure and high-precision Rb isotope measurement in geological materials by using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) in standard-sample-bracketing (SSB) mode has been developed. Sr-Spec resin was employed, in which the distribution coefficients for Rb, K, Ba and Sr are different in nitric acid, to sequentially separate them from the matrix. The dissolved samples were loaded on the column in 3 M HNO3, the main matrix such as Al, Ca, Fe, Mg, Mn and Na were removed by rinsing with 4.5 mL HNO3, Rb and K were then sequentially eluted by 3 M HNO3 in different volumes. After that, Ba was eluted by 8 M HNO3, and Sr was finally eluted by Milli-Q water. This enable us to collect the pure Rb, K, Ba and Sr one by one with recovery close to 100% for their isotopic compositions measurement on MC-ICP-MS. We here focus on Rb isotope measurement. The measurement using MC-ICP-MS yielded an internal precision for δ87Rb of external precision was generally better than ± 0.06‰ (2SD) based on the long-term results of the Rb standard solutions NIST SRM 984. A series of geological rock standards, were analyzed using this method, and the results indicate significant Rb isotope differences in different geologic materials. This will provide a powerful tool to investigate Rb isotope fractionation during geological processes.Based on this method, Rb isotope compositions from a basaltic weathering profile were carried out. The data show the lighter Rb (85Rb) isotope is preferentially leached from the weathering profile and remains heavy Rb isotope (87Rb) in the weathered residues during the incipient weathering stage. From the moderate to advanced weathering stage, the significant variations of Rb isotope were observed and multiple factors, such as leaching, adsorption, desorption, and precipitation, should play important role in fractionating Rb isotope.

  14. A novel heterogeneous training sample selection method on space-time adaptive processing

    Science.gov (United States)

    Wang, Qiang; Zhang, Yongshun; Guo, Yiduo

    2018-04-01

    The performance of ground target detection about space-time adaptive processing (STAP) decreases when non-homogeneity of clutter power is caused because of training samples contaminated by target-like signals. In order to solve this problem, a novel nonhomogeneous training sample selection method based on sample similarity is proposed, which converts the training sample selection into a convex optimization problem. Firstly, the existing deficiencies on the sample selection using generalized inner product (GIP) are analyzed. Secondly, the similarities of different training samples are obtained by calculating mean-hausdorff distance so as to reject the contaminated training samples. Thirdly, cell under test (CUT) and the residual training samples are projected into the orthogonal subspace of the target in the CUT, and mean-hausdorff distances between the projected CUT and training samples are calculated. Fourthly, the distances are sorted in order of value and the training samples which have the bigger value are selective preference to realize the reduced-dimension. Finally, simulation results with Mountain-Top data verify the effectiveness of the proposed method.

  15. Determination of tritium in wine yeast samples

    International Nuclear Information System (INIS)

    Cotarlea, Monica-Ionela; Paunescu Niculina; Galeriu, D; Mocanu, N.; Margineanu, R.; Marin, G.

    1998-01-01

    Analytical procedures were developed to determine tritium in wine and wine yeast samples. The content of organic compounds affecting the LSC measurement is reduced by fractioning distillation for wine samples and azeotropic distillation/fractional distillation for wine yeast samples. Finally, the water samples were normally distilled with K MO 4 . The established procedures were successfully applied for wine and wine samples from Murfatlar harvests of the years 1995 and 1996. (authors)

  16. Probabilistic Round Trip Contamination Analysis of a Mars Sample Acquisition and Handling Process Using Markovian Decompositions

    Science.gov (United States)

    Hudson, Nicolas; Lin, Ying; Barengoltz, Jack

    2010-01-01

    A method for evaluating the probability of a Viable Earth Microorganism (VEM) contaminating a sample during the sample acquisition and handling (SAH) process of a potential future Mars Sample Return mission is developed. A scenario where multiple core samples would be acquired using a rotary percussive coring tool, deployed from an arm on a MER class rover is analyzed. The analysis is conducted in a structured way by decomposing sample acquisition and handling process into a series of discrete time steps, and breaking the physical system into a set of relevant components. At each discrete time step, two key functions are defined: The probability of a VEM being released from each component, and the transport matrix, which represents the probability of VEM transport from one component to another. By defining the expected the number of VEMs on each component at the start of the sampling process, these decompositions allow the expected number of VEMs on each component at each sampling step to be represented as a Markov chain. This formalism provides a rigorous mathematical framework in which to analyze the probability of a VEM entering the sample chain, as well as making the analysis tractable by breaking the process down into small analyzable steps.

  17. Analogous selection processes in declarative and procedural working memory: N-2 list-repetition and task-repetition costs.

    Science.gov (United States)

    Gade, Miriam; Souza, Alessandra S; Druey, Michel D; Oberauer, Klaus

    2017-01-01

    Working memory (WM) holds and manipulates representations for ongoing cognition. Oberauer (Psychology of Learning and Motivation, 51, 45-100, 2009) distinguishes between two analogous WM sub-systems: a declarative WM which handles the objects of thought, and a procedural WM which handles the representations of (cognitive) actions. Here, we assessed whether analogous effects are observed when participants switch between memory sets (declarative representations) and when they switch between task sets (procedural representations). One mechanism assumed to facilitate switching in procedural WM is the inhibition of previously used, but currently irrelevant task sets, as indexed by n-2 task-repetition costs (Mayr & Keele, Journal of Experimental Psychology: General, 129(1), 4-26, 2000). In this study we tested for an analogous effect in declarative WM. We assessed the evidence for n-2 list-repetition costs across eight experiments in which participants switched between memory lists to perform speeded classifications, mental arithmetic, or a local recognition test. N-2 list-repetition costs were obtained consistently in conditions assumed to increase interference between memory lists, and when lists formed chunks in long-term memory. Further analyses across experiments revealed a substantial contribution of episodic memory to n-2 list-repetition costs, thereby questioning the interpretation of n-2 repetition costs as reflecting inhibition. We reanalyzed the data of eight task-switching experiments, and observed that episodic memory also contributes to n-2 task-repetition costs. Taken together, these results show analogous processing principles in declarative and procedural WM, and question the relevance of inhibitory processes for efficient switching between mental sets.

  18. Program Baseline Change Control Procedure

    International Nuclear Information System (INIS)

    1993-02-01

    This procedure establishes the responsibilities and process for approving initial issues of and changes to the technical, cost, and schedule baselines, and selected management documents developed by the Office of Civilian Radioactive Waste Management (OCRWM) for the Civilian Radioactive Waste Management System. This procedure implements the OCRWM Baseline Management Plan and DOE Order 4700.1, Chg 1. It streamlines the change control process to enhance integration, accountability, and traceability of Level 0 and Level I decisions through standardized Baseline Change Proposal (BCP) forms to be used by the Level 0, 1, 2, and 3 Baseline Change Control Boards (BCCBs) and to be tracked in the OCRWM-wide Configuration Information System (CIS) Database.This procedure applies to all technical, cost, and schedule baselines controlled by the Energy System Acquisition Advisory Board (ESAAB) BCCB (Level 0) and, OCRWM Program Baseline Control Board (PBCCB) (Level 1). All baseline BCPs initiated by Level 2 or lower BCCBs, which require approval from ESAAB or PBCCB, shall be processed in accordance with this procedure. This procedure also applies to all Program-level management documents controlled by the OCRWM PBCCB

  19. Preparation Of Deposited Sediment Sample By Casting Method For Environmental Study

    International Nuclear Information System (INIS)

    Hutabarat, Tommy; Ristin PI, Evarista

    2000-01-01

    The preparation of deposited sediment sample by c asting m ethod for environmental study has been carried out. This method comprises separation of size fraction and casting process. The deposited sediment samples were wet sieved to separate the size fraction of >500 mum, (250-500) mum, (125-250) mum and (63-125) mum and settling procedures were followed for the separation of (40-63) mum, (20-40) mum, (10-20) mum and o C, ashed at 450 o C, respectively. In the casting process of sample, it was used polyester rapid cure resin and methyl ethyl ketone peroxide (MEKP) hardener. The moulded sediment sample was poured onto caster, allow for 60 hours long. The aim of this method is to get the casted sample which can be used effectively, efficiently and to be avoided from contamination of each other samples. Before casting, samples were grinded up to be fine. The result shows that casting product is ready to be used for natural radionuclide analysis

  20. Dry sample storage system for an analytical laboratory supporting plutonium processing

    International Nuclear Information System (INIS)

    Treibs, H.A.; Hartenstein, S.D.; Griebenow, B.L.; Wade, M.A.

    1990-01-01

    The Special Isotope Separation (SIS) plant is designed to provide removal of undesirable isotopes in fuel grade plutonium by the atomic vapor laser isotope separation (AVLIS) process. The AVLIS process involves evaporation of plutonium metal, and passage of an intense beam of light from a laser through the plutonium vapor. The laser beam consists of several discrete wavelengths, tuned to the precise wavelength required to ionize the undesired isotopes. These ions are attracted to charged plates, leaving the bulk of the plutonium vapor enriched in the desired isotopes to be collected on a cold plate. Major portions of the process consist of pyrochemical processes, including direct reduction of the plutonium oxide feed material with calcium metal, and aqueous processes for purification of plutonium in residues. The analytical laboratory for the plant is called the Material and Process Control Laboratory (MPCL), and provides for the analysis of solid and liquid process samples

  1. An improved procedure for subcellular spatial alignment during live-cell CLEM.

    Directory of Open Access Journals (Sweden)

    Benjamin S Padman

    Full Text Available Live-cell correlative light and electron microscopy (CLEM offers unique insights into the ultrastructure of dynamic cellular processes. A critical and technically challenging part of CLEM is the 3-dimensional relocation of the intracellular region of interest during sample processing. We have developed a simple CLEM procedure that uses toner particles from a laser printer as orientation marks. This facilitates easy tracking of a region of interest even by eye throughout the whole procedure. Combined with subcellular fluorescence markers for the plasma membrane and nucleus, the toner particles allow for precise subcellular spatial alignment of the optical and electron microscopy data sets. The toner-based reference grid is printed and transferred onto a polymer film using a standard office printer and laminator. We have also designed a polymer film holder that is compatible with most inverted microscopes, and have validated our strategy by following the ultrastructure of mitochondria that were selectively photo-irradiated during live-cell microscopy. In summary, our inexpensive and robust CLEM procedure simplifies optical imaging, without limiting the choice of optical microscope.

  2. Stability of arsenic compounds in seafood samples during processing and storage by freezing

    DEFF Research Database (Denmark)

    Dahl, Lisbeth; Molin, Marianne; Amlund, Heidi

    2010-01-01

    was observed after processing or after storage by freezing. The content of tetramethylarsonium ion was generally low in all samples types, but increased significantly in all fried samples of both fresh and frozen seafood. Upon storage by freezing, the arsenobetaine content was reduced significantly, but only...

  3. Procedure for rapid determination of δ15N and δ18O values of nitrate: development and application to an irrigated rice paddy watershed.

    Science.gov (United States)

    Yada, Saeko; Nakajima, Yasuhiro; Itahashi, Sunao; Asada, Kei; Yoshikawa, Seiko; Eguchi, Sadao

    2016-01-01

    The dual isotope approach using the stable isotope ratios of nitrate nitrogen (δ(15)N(NO3)) and oxygen (δ(18)O(NO3)) is a strong tool for identifying the history of nitrate in various environments. Basically, a rapid procedure for determining δ(15)N(NO3) and δ(18)O(NO3) values is required to analyze many more samples quickly and thus save on the operational costs of isotope-ratio mass spectrometry (IRMS). We developed a new rapid procedure to save time by pre-treating consecutive samples of nitrous oxide microbially converted from nitrate before IRMS determination. By controlling two six-port valves of the pre-treatment system separately, IRMS determination of the current sample and backflush during the next sample pre-treatment period could be conducted simultaneously. A set of 89 samples was analyzed precisely during a 25-h continuous run (17 min per sample), giving the fastest reported processing time, and simultaneously reducing liquid nitrogen and carrier helium gas consumption by 35%. Application of the procedure to an irrigated rice paddy watershed suggested that nitrate concentrations in river waters decreased in a downstream direction, mainly because of the mixing of nitrate from different sources, without distinct evidence of denitrification. Our procedure should help with more detailed studies of nitrate formation processes in watersheds.

  4. How to develop a Standard Operating Procedure for sorting unfixed cells

    Science.gov (United States)

    Schmid, Ingrid

    2012-01-01

    Written Standard Operating Procedures (SOPs) are an important tool to assure that recurring tasks in a laboratory are performed in a consistent manner. When the procedure covered in the SOP involves a high-risk activity such as sorting unfixed cells using a jet-in-air sorter, safety elements are critical components of the document. The details on sort sample handling, sorter set-up, validation, operation, troubleshooting, and maintenance, personal protective equipment (PPE), and operator training, outlined in the SOP are to be based on careful risk assessment of the procedure. This review provides background information on the hazards associated with sorting of unfixed cells and the process used to arrive at the appropriate combination of facility design, instrument placement, safety equipment, and practices to be followed. PMID:22381383

  5. How to develop a standard operating procedure for sorting unfixed cells.

    Science.gov (United States)

    Schmid, Ingrid

    2012-07-01

    Written standard operating procedures (SOPs) are an important tool to assure that recurring tasks in a laboratory are performed in a consistent manner. When the procedure covered in the SOP involves a high-risk activity such as sorting unfixed cells using a jet-in-air sorter, safety elements are critical components of the document. The details on sort sample handling, sorter set-up, validation, operation, troubleshooting, and maintenance, personal protective equipment (PPE), and operator training, outlined in the SOP are to be based on careful risk assessment of the procedure. This review provides background information on the hazards associated with sorting of unfixed cells and the process used to arrive at the appropriate combination of facility design, instrument placement, safety equipment, and practices to be followed. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Study for process and equipment design of wet gelation stages in vibropacking process

    International Nuclear Information System (INIS)

    Tanimoto, Ryoji; Kikuchi, Toshiaki; Tanaka, Hirokazu; Amino, Masaki; Yanai, Minoru

    2004-02-01

    Process and layout design of external wet gelation stages in vibropacking process was examined for the feasibility study of commercialized FBR cycle system. In this study, following process stages for the oxide core fuel production line were covered, that is, solidification, washing, drying, calcination, reduction, sintering stages including interim storage of sintering particles and reagent recovery stage. The main results obtained by this study are as follows: (1) Based on the process examination results conducted previously, process-flow, mass-balance and number of production line/equipment were clarified. The process is covered from the receive tank of feed solution to the interim storage equipment. Reagent recovery process-flow, mass-balance were also clarified. And preliminary design of the main equipment was reexamined. (2) Normal operation procedure and the procedure after process failure were summarized along with a remote automated operation procedure. Operation sequence of each production line was mapped out by using a time-chart. (3) Design outline of reagent recovery equipments, installed to recover waste liquid from the wet gelation stages in the view of environmental impact were examined. Effective techniques such as collection of solvent, residue waste treatment method were examined its applicability and selected. Schematic block diagram was presented. (4) Analytical items and analyzing apparatus were extracted taking into account of quality control and process management. Analytical sample taking position and frequency of sampling were also examined. (5) A schematic layout drawing of main manufacturing process and reagent recovery process was presented taking into account of material handling. (6) A feature of the operating rate at each process stage was examined by analyzing failure rate reliability of each component. applying the reliability-centred method. (RCM), the operating rate was evaluated and annual maintenance period was estimated using

  7. Sampling analytical tests and destructive tests for quality assurance

    International Nuclear Information System (INIS)

    Saas, A.; Pasquini, S.; Jouan, A.; Angelis, de; Hreen Taywood, H.; Odoj, R.

    1990-01-01

    In the context of the third programme of the European Communities on the monitoring of radioactive waste, various methods have been developed for the performance of sampling and measuring tests on encapsulated waste of low and medium level activity, on the one hand, and of high level activity, on the other hand. The purpose was to provide better quality assurance for products to be stored on an interim or long-term basis. Various testing sampling means are proposed such as: - sampling of raw waste before conditioning and determination of the representative aliquot, - sampling of encapsulated waste on process output, - sampling of core specimens subjected to measurement before and after cutting. Equipment suitable for these sampling procedures have been developed and, in the case of core samples, a comparison of techniques has been made. The results are described for the various analytical tests carried out on the samples such as: - mechanical tests, - radiation resistance, - fire resistance, - lixiviation, - determination of free water, - biodegradation, - water resistance, - chemical and radiochemical analysis. Every time it was possible, these tests were compared with non-destructive tests on full-scale packages and some correlations are given. This word has made if possible to improve and clarify sample optimization, with fine sampling techniques and methodologies and draw up characterization procedures. It also provided an occasion for a first collaboration between the laboratories responsible for these studies and which will be furthered in the scope of the 1990-1994 programme

  8. Surface Environmental Surveillance Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Hanf, RW; Dirkes, RL

    1990-02-01

    This manual establishes the procedures for the collection of environmental samples and the performance of radiation surveys and other field measurements. Responsibilities are defined for those personnel directly involved in the collection of samples and the performance of field measurements.

  9. Environmental Measurements Laboratory (EML) procedures manual

    International Nuclear Information System (INIS)

    Chieco, N.A.; Bogen, D.C.; Knutson, E.O.

    1990-11-01

    Volume 1 of this manual documents the procedures and existing technology that are currently used by the Environmental Measurements Laboratory. A section devoted to quality assurance has been included. These procedures have been updated and revised and new procedures have been added. They include: sampling; radiation measurements; analytical chemistry; radionuclide data; special facilities; and specifications. 228 refs., 62 figs., 37 tabs. (FL)

  10. Additional Samples: Where They Should Be Located

    International Nuclear Information System (INIS)

    Pilger, G. G.; Costa, J. F. C. L.; Koppe, J. C.

    2001-01-01

    Information for mine planning requires to be close spaced, if compared to the grid used for exploration and resource assessment. The additional samples collected during quasimining usually are located in the same pattern of the original diamond drillholes net but closer spaced. This procedure is not the best in mathematical sense for selecting a location. The impact of an additional information to reduce the uncertainty about the parameter been modeled is not the same everywhere within the deposit. Some locations are more sensitive in reducing the local and global uncertainty than others. This study introduces a methodology to select additional sample locations based on stochastic simulation. The procedure takes into account data variability and their spatial location. Multiple equally probable models representing a geological attribute are generated via geostatistical simulation. These models share basically the same histogram and the same variogram obtained from the original data set. At each block belonging to the model a value is obtained from the n simulations and their combination allows one to access local variability. Variability is measured using an uncertainty index proposed. This index was used to map zones of high variability. A value extracted from a given simulation is added to the original data set from a zone identified as erratic in the previous maps. The process of adding samples and simulation is repeated and the benefit of the additional sample is evaluated. The benefit in terms of uncertainty reduction is measure locally and globally. The procedure showed to be robust and theoretically sound, mapping zones where the additional information is most beneficial. A case study in a coal mine using coal seam thickness illustrates the method

  11. Implementation guide for turbidity threshold sampling: principles, procedures, and analysis

    Science.gov (United States)

    Jack Lewis; Rand Eads

    2009-01-01

    Turbidity Threshold Sampling uses real-time turbidity and river stage information to automatically collect water quality samples for estimating suspended sediment loads. The system uses a programmable data logger in conjunction with a stage measurement device, a turbidity sensor, and a pumping sampler. Specialized software enables the user to control the sampling...

  12. 40 CFR 68.52 - Operating procedures.

    Science.gov (United States)

    2010-07-01

    ...) CHEMICAL ACCIDENT PREVENTION PROVISIONS Program 2 Prevention Program § 68.52 Operating procedures. (a) The... for safely conducting activities associated with each covered process consistent with the safety information for that process. Operating procedures or instructions provided by equipment manufacturers or...

  13. Neural changes associated to procedural learning and automatization process in Developmental Coordination Disorder and/or Developmental Dyslexia.

    Science.gov (United States)

    Biotteau, Maëlle; Péran, Patrice; Vayssière, Nathalie; Tallet, Jessica; Albaret, Jean-Michel; Chaix, Yves

    2017-03-01

    Recent theories hypothesize that procedural learning may support the frequent overlap between neurodevelopmental disorders. The neural circuitry supporting procedural learning includes, among others, cortico-cerebellar and cortico-striatal loops. Alteration of these loops may account for the frequent comorbidity between Developmental Coordination Disorder (DCD) and Developmental Dyslexia (DD). The aim of our study was to investigate cerebral changes due to the learning and automatization of a sequence learning task in children with DD, or DCD, or both disorders. fMRI on 48 children (aged 8-12) with DD, DCD or DD + DCD was used to explore their brain activity during procedural tasks, performed either after two weeks of training or in the early stage of learning. Firstly, our results indicate that all children were able to perform the task with the same level of automaticity, but recruit different brain processes to achieve the same performance. Secondly, our fMRI results do not appear to confirm Nicolson and Fawcett's model. The neural correlates recruited for procedural learning by the DD and the comorbid groups are very close, while the DCD group presents distinct characteristics. This provide a promising direction on the neural mechanisms associated with procedural learning in neurodevelopmental disorders and for understanding comorbidity. Published by Elsevier Ltd.

  14. Impact of implementing ISO 9001:2008 standard on the Spanish Renal Research Network biobank sample transfer process.

    Science.gov (United States)

    Cortés, M Alicia; Irrazábal, Emanuel; García-Jerez, Andrea; Bohórquez-Magro, Lourdes; Luengo, Alicia; Ortiz-Arduán, Alberto; Calleros, Laura; Rodríguez-Puyol, Manuel

    2014-01-01

    Biobank certification ISO 9001:2008 aims to improve the management of processes performed. This has two objectives: customer satisfaction and continuous improvement. This paper presents the impact of certification ISO 9001:2008 on the sample transfer process in a Spanish biobank specialising in kidney patient samples. The biobank experienced a large increase in the number of samples between 2009 (12,582 vials) and 2010 (37,042 vials). The biobank of the Spanish Renal Research Network (REDinREN), located at the University of Alcalá, has implemented ISO standard 9001:2008 for the effective management of human material given to research centres. Using surveys, we analysed two periods in the “sample transfer” process. During the first period between 1-10-12 and 26-11-12 (8 weeks), minimal changes were made to correct isolated errors. In the second period, between 7-01-13 and 18-02-13 (6 weeks), we carried out general corrective actions. The identification of problems and implementation of corrective actions for certification allowed: a 70% reduction in the process execution time, a significant increase (200%) in the number of samples processed and a 25% improvement in the process. The increase in the number of samples processed was directly related to process improvement. The certification of ISO standard 9001:2008, obtained in July 2013, allowed an improvement of the REDinREN biobank processes to be achieved, which increased quality and customer satisfaction.

  15. The impact of a medical procedure service on patient safety, procedure quality and resident training opportunities.

    Science.gov (United States)

    Tukey, Melissa H; Wiener, Renda Soylemez

    2014-03-01

    At some academic hospitals, medical procedure services are being developed to provide supervision for residents performing bedside procedures in hopes of improving patient safety and resident education. There is limited knowledge of the impact of such services on procedural complication rates and resident procedural training opportunities. To determine the impact of a medical procedure service (MPS) on patient safety and resident procedural training opportunities. Retrospective cohort analysis comparing characteristics and outcomes of procedures performed by the MPS versus the primary medical service. Consecutive adults admitted to internal medicine services at a large academic hospital who underwent a bedside medical procedure (central venous catheterization, thoracentesis, paracentesis, lumbar puncture) between 1 July 2010 and 31 December 2011. The primary outcome was a composite rate of major complications. Secondary outcomes included resident participation in bedside procedures and use of "best practice" safety process measures. We evaluated 1,707 bedside procedures (548 by the MPS, 1,159 by the primary services). There were no differences in the composite rate of major complications (1.6 % vs. 1.9 %, p = 0.71) or resident participation in bedside procedures (57.0 % vs. 54.3 %, p = 0.31) between the MPS and the primary services. Procedures performed by the MPS were more likely to be successfully completed (95.8 % vs. 92.8 %, p = 0.02) and to use best practice safety process measures, including use of ultrasound guidance when appropriate (96.8 % vs. 90.0 %, p = 0.0004), avoidance of femoral venous catheterization (89.5 vs. 82.7 %, p = 0.02) and involvement of attending physicians (99.3 % vs. 57.0 %, p < 0.0001). Although use of a MPS did not significantly affect the rate of major complications or resident opportunities for training in bedside procedures, it was associated with increased use of best practice safety process measures.

  16. Robust weak measurements on finite samples

    International Nuclear Information System (INIS)

    Tollaksen, Jeff

    2007-01-01

    A new weak measurement procedure is introduced for finite samples which yields accurate weak values that are outside the range of eigenvalues and which do not require an exponentially rare ensemble. This procedure provides a unique advantage in the amplification of small nonrandom signals by minimizing uncertainties in determining the weak value and by minimizing sample size. This procedure can also extend the strength of the coupling between the system and measuring device to a new regime

  17. Procedural Rationality in the Decision-Making of Internationalizing SMEs

    DEFF Research Database (Denmark)

    Hsieh, Linda; Elbanna, Said; Narooz, Rose

    This paper contributes to the growing body of empirical work on how SME decision-makers decide to internationalize in two ways: first, it responds to recent calls for incorporating strategic decision-making literature into understanding SME internationalization decisions. Second, it provides a be...... a more rational decision-making procedure when they perceive a high level of international risk. The evidence also suggest that internationalization performance, planned internationalization, credit check, and decision team size are positively related to procedural rationality....... a better understanding of under what circumstances, SME decision-makers tend to follow a more rational approach toward internationalization decisions. Specifically, this paper examines a set of contextual variables (the level of perceived international risk, internationalization performance, planned versus...... ad hoc internationalization, credit check, distribution adaptation, and decision team size) and their influence on the extent of procedural rationality in SME internationalization decision-making process. The findings from a sample of 176 export-active SMEs show that decision-makers tend to follow...

  18. Design/Operations review of core sampling trucks and associated equipment

    International Nuclear Information System (INIS)

    Shrivastava, H.P.

    1996-01-01

    A systematic review of the design and operations of the core sampling trucks was commissioned by Characterization Equipment Engineering of the Westinghouse Hanford Company in October 1995. The review team reviewed the design documents, specifications, operating procedure, training manuals and safety analysis reports. The review process, findings and corrective actions are summarized in this supporting document

  19. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks

    Energy Technology Data Exchange (ETDEWEB)

    Bernini, Patrizia; Bertini, Ivano, E-mail: bertini@cerm.unifi.it; Luchinat, Claudio [University of Florence, Magnetic Resonance Center (CERM) (Italy); Nincheri, Paola; Staderini, Samuele [FiorGen Foundation (Italy); Turano, Paola [University of Florence, Magnetic Resonance Center (CERM) (Italy)

    2011-04-15

    {sup 1}H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0-4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  20. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks.

    Science.gov (United States)

    Bernini, Patrizia; Bertini, Ivano; Luchinat, Claudio; Nincheri, Paola; Staderini, Samuele; Turano, Paola

    2011-04-01

    (1)H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0-4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  1. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks

    International Nuclear Information System (INIS)

    Bernini, Patrizia; Bertini, Ivano; Luchinat, Claudio; Nincheri, Paola; Staderini, Samuele; Turano, Paola

    2011-01-01

    1 H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0−4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  2. Solubility of airborne uranium samples from uranium processing plant

    International Nuclear Information System (INIS)

    Kravchik, T.; Oved, S.; Sarah, R.; Gonen, R.; Paz-Tal, O.; Pelled, O.; German, U.; Tshuva, A.

    2005-01-01

    Full text: During the production and machining processes of uranium metal, aerosols might be released to the air. Inhalation of these aerosols is the main route of internal exposure of workers. To assess the radiation dose from the intake of these uranium compounds it is necessary to know their absorption type, based on their dissolution rate in extracellular aqueous environment of lung fluid. The International Commission on Radiological Protection (ICRP) has assigned UF4 and U03 to absorption type M (blood absorption which contains a 10 % fraction with an absorption rate of 10 minutes and 90 % fraction with an absorption rate of 140 fays) and UO2 and U3O8 to absorption type S (blood absorption rate with a half-time of 7000 days) in the ICRP-66 model.The solubility classification of uranium compounds defined by the ICRP can serve as a general guidance. At specific workplaces, differences can be encountered, because of differences in compounds production process and the presence of additional compounds, with different solubility characteristics. According to ICRP recommendations, material-specific rates of absorption should be preferred to default parameters whenever specific experimental data exists. Solubility profiles of uranium aerosols were determined by performing in vitro chemical solubility tests on air samples taken from uranium production and machining facilities. The dissolution rate was determined over 100 days in a simultant solution of the extracellular airway lining fluid. The filter sample was immersed in a test vial holding 60 ml of simultant fluid, which was maintained at a 37 o C inside a thermostatic bath and at a physiological pH of 7.2-7.6. The test vials with the solution were shaken to simulate the conditions inside the extracellular aqueous environment of the lung as much as possible. The tests indicated that the uranium aerosols samples taken from the metal production and machining facilities at the Nuclear Research Center Negev (NRCN

  3. Sample preparation combined with electroanalysis to improve simultaneous determination of antibiotics in animal derived food samples.

    Science.gov (United States)

    da Silva, Wesley Pereira; de Oliveira, Luiz Henrique; Santos, André Luiz Dos; Ferreira, Valdir Souza; Trindade, Magno Aparecido Gonçalves

    2018-06-01

    A procedure based on liquid-liquid extraction (LLE) and phase separation using magnetically stirred salt-induced high-temperature liquid-liquid extraction (PS-MSSI-HT-LLE) was developed to extract and pre-concentrate ciprofloxacin (CIPRO) and enrofloxacin (ENRO) from animal food samples before electroanalysis. Firstly, simple LLE was used to extract the fluoroquinolones (FQs) from animal food samples, in which dilution was performed to reduce interference effects to below a tolerable threshold. Then, adapted PS-MSSI-HT-LLE protocols allowed re-extraction and further pre-concentration of target analytes in the diluted acid samples for simultaneous electrochemical quantification at low concentration levels. To improve the peak separation, in simultaneous detection, a baseline-corrected second-order derivative approach was processed. These approaches allowed quantification of target FQs from animal food samples spiked at levels of 0.80 to 2.00 µmol L -1 in chicken meat, with recovery values always higher than 80.5%, as well as in milk samples spiked at 4.00 µmol L -1 , with recovery values close to 70.0%. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Procedures for mastitis diagnosis and control.

    Science.gov (United States)

    Sears, P M; González, R N; Wilson, D J; Han, H R

    1993-11-01

    Procedures for mastitis diagnosis and control include culturing individual cow and bulk tank milk samples, antibiotic susceptibility testing, and evaluation of somatic cell count reports and clinical mastitis treatment records. Integrated use of such procedures is necessary for effective mastitis diagnosis and control.

  5. Evaluation of mercury retention during the lyophilization process

    International Nuclear Information System (INIS)

    Monteiro, Lucilena R.; Costa, Manuel Q. da

    1997-01-01

    Shrimp and fish samples were studied by comparing the mercury retention during the freeze drying process. Advantages and disadvantages of this technique, a preview procedure, were identified. The food response concerning water mass los and stability on storage are evaluated after freeze drying process. (author). 10 refs., 4 figs., 2 tabs

  6. Highly Reproducible Automated Proteomics Sample Preparation Workflow for Quantitative Mass Spectrometry.

    Science.gov (United States)

    Fu, Qin; Kowalski, Michael P; Mastali, Mitra; Parker, Sarah J; Sobhani, Kimia; van den Broek, Irene; Hunter, Christie L; Van Eyk, Jennifer E

    2018-01-05

    Sample preparation for protein quantification by mass spectrometry requires multiple processing steps including denaturation, reduction, alkylation, protease digestion, and peptide cleanup. Scaling these procedures for the analysis of numerous complex biological samples can be tedious and time-consuming, as there are many liquid transfer steps and timed reactions where technical variations can be introduced and propagated. We established an automated sample preparation workflow with a total processing time for 96 samples of 5 h, including a 2 h incubation with trypsin. Peptide cleanup is accomplished by online diversion during the LC/MS/MS analysis. In a selected reaction monitoring (SRM) assay targeting 6 plasma biomarkers and spiked β-galactosidase, mean intraday and interday cyclic voltammograms (CVs) for 5 serum and 5 plasma samples over 5 days were samples repeated on 3 separate days had total CVs below 20%. Similar results were obtained when the workflow was transferred to a second site: 93% of peptides had CVs below 20%. An automated trypsin digestion workflow yields uniformly processed samples in less than 5 h. Reproducible quantification of peptides was observed across replicates, days, instruments, and laboratory sites, demonstrating the broad applicability of this approach.

  7. Fractionation of metals in street sediment samples by using the BCR sequential extraction procedure and multivariate statistical elucidation of the data

    International Nuclear Information System (INIS)

    Kartal, Senol; Aydin, Zeki; Tokalioglu, Serife

    2006-01-01

    The concentrations of metals (Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, and Zn) in street sediment samples were determined by flame atomic absorption spectrometry (FAAS) using the modified BCR (the European Community Bureau of Reference) sequential extraction procedure. According to the BCR protocol for extracting the metals from the relevant target phases, 1.0 g of specimen of the sample was treated with 0.11 M acetic acid (exchangeable and bound to carbonates), 0.5 M hydroxylamine hydrochloride (bound to iron- and manganese-oxides), and 8.8 M hydrogen peroxide plus 1 M ammonium acetate (bound to sulphides and organics), sequentially. The residue was treated with aqua regia solution for recovery studies, although this step is not part of the BCR procedure. The mobility sequence based on the sum of the BCR sequential extraction stages was: Cd ∼ Zn (∼90%) > Pb (∼84%) > Cu (∼75%) > Mn (∼70%) > Co (∼57%) > Ni (∼43%) > Cr (∼40%) > Fe (∼17%). Enrichment factors as the criteria for examining the impact of the anthropogenic emission sources of heavy metals were calculated, and it was observed that the highest enriched elements were Cd, Pb, and Zn in the dust samples, average 190, 111, and 20, respectively. Correlation analysis (CA) and principal component analysis (PCA) were applied to the data matrix to evaluate the analytical results and to identify the possible pollution sources of metals. PCA revealed that the sampling area was mainly influenced from three pollution sources, namely; traffic, industrial, and natural sources. The results show that chemical sequential extraction is a precious operational tool. Validation of the analytical results was checked by both recovery studies and analysis of the standard reference material (NIST SRM 2711 Montana Soil)

  8. REMOTE IN-CELL SAMPLING IMPROVEMENTS PROGRAM AT THESAVANNAH RIVER SITE (SRS) DEFENSE WASTE PROCESSING FACILITY (DWPF)

    International Nuclear Information System (INIS)

    Marzolf, A

    2007-01-01

    Remote Systems Engineering (RSE) of the Savannah River National Lab (SRNL) in combination with the Defense Waste Processing Facility(DWPF) Engineering and Operations has evaluated the existing equipment and processes used in the facility sample cells for 'pulling' samples from the radioactive waste stream and performing equipment in-cell repairs/replacements. RSE has designed and tested equipment for improving remote in-cell sampling evolutions and reducing the time required for in-cell maintenance of existing equipment. The equipment within the present process tank sampling system has been in constant use since the facility start-up over 17 years ago. At present, the method for taking samples within the sample cells produces excessive maintenance and downtime due to frequent failures relative to the sampling station equipment and manipulator. Location and orientation of many sampling stations within the sample cells is not conducive to manipulator operation. The overextension of manipulators required to perform many in-cell operations is a major cause of manipulator failures. To improve sampling operations and reduce downtime due to equipment maintenance, a Portable Sampling Station (PSS), wireless in-cell cameras, and new commercially available sampling technology has been designed, developed and/or adapted and tested. The uniqueness of the design(s), the results of the scoping tests, and the benefits relative to in-cell operation and reduction of waste are presented

  9. Data Validation Package - April and July 2015 Groundwater and Surface Water Sampling at the Gunnison, Colorado, Processing Site

    Energy Technology Data Exchange (ETDEWEB)

    Linard, Joshua [Dept. of Energy (DOE), Washington, DC (United States). Office of Legacy Management; Campbell, Sam [Navarro Research and Engineering, Inc., Oak Ridge, TN (United States)

    2016-02-01

    This event included annual sampling of groundwater and surface water locations at the Gunnison, Colorado, Processing Site. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites. Samples were collected from 28 monitoring wells, three domestic wells, and six surface locations in April at the processing site as specified in the 2010 Ground Water Compliance Action Plan for the Gunnison, Colorado, Processing Site. Domestic wells 0476 and 0477 were sampled in July because the homes were unoccupied in April, and the wells were not in use. Duplicate samples were collected from locations 0113, 0248, and 0477. One equipment blank was collected during this sampling event. Water levels were measured at all monitoring wells that were sampled. No issues were identified during the data validation process that requires additional action or follow-up.

  10. Special nuclear material inventory sampling plans

    International Nuclear Information System (INIS)

    Vaccaro, H.; Goldman, A.

    1987-01-01

    Since their introduction in 1942, sampling inspection procedures have been common quality assurance practice. The U.S. Department of Energy (DOE) supports such sampling of special nuclear materials inventories. The DOE Order 5630.7 states, Operations Offices may develop and use statistically valid sampling plans appropriate for their site-specific needs. The benefits for nuclear facilities operations include reduced worker exposure and reduced work load. Improved procedures have been developed for obtaining statistically valid sampling plans that maximize these benefits. The double sampling concept is described and the resulting sample sizes for double sample plans are compared with other plans. An algorithm is given for finding optimal double sampling plans that assist in choosing the appropriate detection and false alarm probabilities for various sampling plans

  11. Global Threat Reduction Initiative Fuel Thermo-Physical Characterization Project: Sample Management Plan

    Energy Technology Data Exchange (ETDEWEB)

    Casella, Amanda J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Pereira, Mario M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Steen, Franciska H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-01-01

    This sample management plan provides guidelines for sectioning, preparation, acceptance criteria, analytical path, and end-of-life disposal for the fuel element segments utilized in the Global Threat Reduction Initiative (GTRI), Fuel Thermo-Physical Characterization Project. The Fuel Thermo-Physical Characterization Project is tasked with analysis of irradiated Low Enriched Uranium (LEU) Molybdenum (U-Mo) fuel element samples to support the GTRI conversion program. Sample analysis may include optical microscopy (OM), scanning electron microscopy (SEM) fuel-surface interface analysis, gas pycnometry (density) measurements, laser flash analysis (LFA), differential scanning calorimetry (DSC), thermogravimetry and differential thermal analysis with mass spectroscopy (TG /DTA-MS), Inductively Coupled Plasma Spectrophotometry (ICP), alpha spectroscopy, and Thermal Ionization Mass Spectroscopy (TIMS). The project will utilize existing Radiochemical Processing Laboratory (RPL) operating, technical, and administrative procedures for sample receipt, processing, and analyses. Test instructions (TIs), which are documents used to provide specific details regarding the implementation of an existing RPL approved technical or operational procedure, will also be used to communicate to staff project specific parameters requested by the Principal Investigator (PI). TIs will be developed, reviewed, and issued in accordance with the latest revision of the RPL-PLN-700, RPL Operations Plan. Additionally, the PI must approve all project test instructions and red-line changes to test instructions.

  12. Progressive sample processing of band selection for hyperspectral imagery

    Science.gov (United States)

    Liu, Keng-Hao; Chien, Hung-Chang; Chen, Shih-Yu

    2017-10-01

    Band selection (BS) is one of the most important topics in hyperspectral image (HSI) processing. The objective of BS is to find a set of representative bands that can represent the whole image with lower inter-band redundancy. Many types of BS algorithms were proposed in the past. However, most of them can be carried on in an off-line manner. It means that they can only be implemented on the pre-collected data. Those off-line based methods are sometime useless for those applications that are timeliness, particular in disaster prevention and target detection. To tackle this issue, a new concept, called progressive sample processing (PSP), was proposed recently. The PSP is an "on-line" framework where the specific type of algorithm can process the currently collected data during the data transmission under band-interleavedby-sample/pixel (BIS/BIP) protocol. This paper proposes an online BS method that integrates a sparse-based BS into PSP framework, called PSP-BS. In PSP-BS, the BS can be carried out by updating BS result recursively pixel by pixel in the same way that a Kalman filter does for updating data information in a recursive fashion. The sparse regression is solved by orthogonal matching pursuit (OMP) algorithm, and the recursive equations of PSP-BS are derived by using matrix decomposition. The experiments conducted on a real hyperspectral image show that the PSP-BS can progressively output the BS status with very low computing time. The convergence of BS results during the transmission can be quickly achieved by using a rearranged pixel transmission sequence. This significant advantage allows BS to be implemented in a real time manner when the HSI data is transmitted pixel by pixel.

  13. Nevada Applied Ecology Group procedures handbook for environmental transuranics

    International Nuclear Information System (INIS)

    White, M.G.; Dunaway, P.B.

    1976-10-01

    The activities of the Nevada Applied Ecology Group (NAEG) integrated research studies of environmental plutonium and other transuranics at the Nevada Test Site have required many standardized field and laboratory procedures. These include sampling techniques, collection and preparation, radiochemical and wet chemistry analysis, data bank storage and reporting, and statistical considerations for environmental samples of soil, vegetation, resuspended particles, animals, and other biological material. This document, printed in two volumes, includes most of the Nevada Applied Ecology Group standard procedures, with explanations as to the specific applications involved in the environmental studies. Where there is more than one document concerning a procedure, it has been included to indicate special studies or applications more complex than the routine standard sampling procedures utilized

  14. Nevada Applied Ecology Group procedures handbook for environmental transuranics

    International Nuclear Information System (INIS)

    White, M.G.; Dunaway, P.B.

    1976-10-01

    The activities of the Nevada Applied Ecology Group (NAEG) integrated research studies of environmental plutonium and other transuranics at the Nevada Test Site have required many standardized field and laboratory procedures. These include sampling techniques, collection and preparation, radiochemical and wet chemistry analysis, data bank storage and reporting, and statistical considerations for environmental samples of soil, vegetation, resuspended particles, animals, and others. This document, printed in two volumes, includes most of the Nevada Applied Ecology Group standard procedures, with explanations as to the specific applications involved in the environmental studies. Where there is more than one document concerning a procedure, it has been included to indicate special studies or applications perhaps more complex than the routine standard sampling procedures utilized

  15. Sampling and monitoring for the mine life cycle

    Science.gov (United States)

    McLemore, Virginia T.; Smith, Kathleen S.; Russell, Carol C.

    2014-01-01

    Sampling and Monitoring for the Mine Life Cycle provides an overview of sampling for environmental purposes and monitoring of environmentally relevant variables at mining sites. It focuses on environmental sampling and monitoring of surface water, and also considers groundwater, process water streams, rock, soil, and other media including air and biological organisms. The handbook includes an appendix of technical summaries written by subject-matter experts that describe field measurements, collection methods, and analytical techniques and procedures relevant to environmental sampling and monitoring.The sixth of a series of handbooks on technologies for management of metal mine and metallurgical process drainage, this handbook supplements and enhances current literature and provides an awareness of the critical components and complexities involved in environmental sampling and monitoring at the mine site. It differs from most information sources by providing an approach to address all types of mining influenced water and other sampling media throughout the mine life cycle.Sampling and Monitoring for the Mine Life Cycle is organized into a main text and six appendices that are an integral part of the handbook. Sidebars and illustrations are included to provide additional detail about important concepts, to present examples and brief case studies, and to suggest resources for further information. Extensive references are included.

  16. Enantioselective behaviour of tetraconazole during strawberry wine-making process.

    Science.gov (United States)

    Liu, Na; Pan, Xinglu; Zhang, Shuang; Ji, Mingshan; Zhang, Zhihong

    2018-05-01

    The fate of tetraconazole enantiomers in strawberries during wine-making process was studied. The residues were determined by ultra-performance convergence chromatography tandem triple quadrupole mass spectrometry after each process steps. Results indicated that there was significant enantioselective dissipation of tetraconazole enantiomers during the fermentation process. And (-)-tetraconazole degraded faster than (+)-tetraconazole. The half-lives of (-)-tetraconazole and (+)-tetraconazole were 3.12, 3.76 days with washing procedure and 3.18, 4.05 days without washing procedure. The processing factors of strawberry wine samples after each step were generally less than 1. In particular, the processing factors of the fermentation process were the lowest. The results could help facilitate more accurate risk assessments of tetraconazole during wine-making process. © 2018 Wiley Periodicals, Inc.

  17. The PDS-based Data Processing, Archiving and Management Procedures in Chang'e Mission

    Science.gov (United States)

    Zhang, Z. B.; Li, C.; Zhang, H.; Zhang, P.; Chen, W.

    2017-12-01

    PDS is adopted as standard format of scientific data and foundation of all data-related procedures in Chang'e mission. Unlike the geographically distributed nature of the planetary data system, all procedures of data processing, archiving, management and distribution are proceeded in the headquarter of Ground Research and Application System of Chang'e mission in a centralized manner. The RAW data acquired by the ground stations is transmitted to and processed by data preprocessing subsystem (DPS) for the production of PDS-compliant Level 0 Level 2 data products using established algorithms, with each product file being well described using an attached label, then all products with the same orbit number are put together into a scheduled task for archiving along with a XML archive list file recoding all product files' properties such as file name, file size etc. After receiving the archive request from DPS, data management subsystem (DMS) is provoked to parse the XML list file to validate all the claimed files and their compliance to PDS using a prebuilt data dictionary, then to exact metadata of each data product file from its PDS label and the fields of its normalized filename. Various requirements of data management, retrieving, distribution and application can be well met using the flexible combination of the rich metadata empowered by the PDS. In the forthcoming CE-5 mission, all the design of data structure and procedures will be updated from PDS version 3 used in previous CE-1, CE-2 and CE-3 missions to the new version 4, the main changes would be: 1) a dedicated detached XML label will be used to describe the corresponding scientific data acquired by the 4 instruments carried, the XML parsing framework used in archive list validation will be reused for the label after some necessary adjustments; 2) all the image data acquired by the panorama camera, landing camera and lunar mineralogical spectrometer should use an Array_2D_Image/Array_3D_Image object to store

  18. Grid - a fast threshold tracking procedure

    DEFF Research Database (Denmark)

    Fereczkowski, Michal; Dau, Torsten; MacDonald, Ewen

    2016-01-01

    A new procedure, called “grid”, is evaluated that allows rapid acquisition of threshold curves for psychophysics and, in particular, psychoacoustic, experiments. In this method, the parameterresponse space is sampled in two dimensions within a single run. This allows the procedure to focus more e...

  19. 21 CFR 211.110 - Sampling and testing of in-process materials and drug products.

    Science.gov (United States)

    2010-04-01

    ... PHARMACEUTICALS Production and Process Controls § 211.110 Sampling and testing of in-process materials and drug... capsule weight variation; (2) Disintegration time; (3) Adequacy of mixing to assure uniformity and... production process, e.g., at commencement or completion of significant phases or after storage for long...

  20. Quality assurance and quality control procedures in river water radioecological monitoring

    International Nuclear Information System (INIS)

    Nalbandyan, A.; Stepanyan, A.

    2006-01-01

    For recent decades the issue of radioactive pollution of environmental components has acquired a global character as a result of nuclear weapon testing, accidents in NPPs, development of nuclear technologies and so on. A study object of this research is river water as it is known to be radionuclide transport and accumulation mediums and radioactive elements in river water are available as radioactive salts and mechanic and biological pollutants. Moreover, river water is widely used for various economic and commercial purposes and serves a drinking water supply source as well. The ongoing research is performed in the frame of a NATO/OSCE project 'South Caucasus River Monitoring'. The topicality of the problem dictates a necessity of getting credible and compatible results. For adequate radioactive pollution assessment, decisive are the application and keeping standard QA/QC procedures at all the stages of radioecological monitoring. In our research we apply the following ISO standard-based QA/QC procedures: sampling (emphasizing sample identification: sample collection site, date and method), sample transportation (keeping sample conservation and storing requirements), sample treatment and preparation in the lab, radiometric measurements of samples with regard for the time that past from sampling moment to analysis, control and calibration of analytic instruments, control analysis of samples. The obtained data are processed through standard statistic methods of QC to check measurement errors. Gamma-spectrometric measurements are maid using a Genie-2000 (Canberra) software that includes a separate program for measurement QC. The ultimate outcomes are arranged in special protocols (analysis and sampling tasks protocols, sampling task form, field measurement protocol, sample chain of custody form, sample analysis protocol) and compiled in appropriate databases

  1. TCLP Preparation and Analysis of K East Basin Composite Sludge Samples

    International Nuclear Information System (INIS)

    Silvers, K.L.; Wagner, J.J.; Steele, R.T.

    2000-01-01

    Sludge samples from the Hanford K East Basin were analyzed by the Toxicity Characterization Leaching Procedure (TCLP) to assist in the appropriate Resource Conservation and Recovery Act (RCIL4) designation of this material. Sludge samples were collected by Fluor Hanford, Inc. using the consolidated sludge sampling system (system that allows collection of a single sample from multiple sample locations). These samples were shipped to the Postirradiation Testing Laboratory (PTL, 327 Building) and then transferred to the Pacific Northwest National Laboratory (PNNL) Radiochemical Processing Laboratory (RPL, 325 Building) for recovery and testing. Two sludge composites were prepared, using the consolidated sludge samples, to represent K East canister sludge (sample KC Can Comp) and K East floor sludge (sample KC Floor Comp). Each composite was extracted in duplicate and analyzed in duplicate following pre-approved(a) TCLP extraction and analyses procedures. In addition, these samples and duplicates were analyzed for total RCRA metals (via acid digestion preparation). The work was conducted in accordance with the requirements of the Hanford Analytical Quality Assurance Requirements Document (HASQARD). A PNNL Quality Assurance Program compliant with J HASQARD was implemented for this effort. The results from the TCLP analyses showed that all RCRA metal concentrations were less than the TCLP limits for both the canister and floor composite samples and their respective duplicates

  2. Critical evaluation of sample pretreatment techniques.

    Science.gov (United States)

    Hyötyläinen, Tuulia

    2009-06-01

    Sample preparation before chromatographic separation is the most time-consuming and error-prone part of the analytical procedure. Therefore, selecting and optimizing an appropriate sample preparation scheme is a key factor in the final success of the analysis, and the judicious choice of an appropriate procedure greatly influences the reliability and accuracy of a given analysis. The main objective of this review is to critically evaluate the applicability, disadvantages, and advantages of various sample preparation techniques. Particular emphasis is placed on extraction techniques suitable for both liquid and solid samples.

  3. A new tool for the evaluation of the analytical procedure: Green Analytical Procedure Index.

    Science.gov (United States)

    Płotka-Wasylka, J

    2018-05-01

    A new means for assessing analytical protocols relating to green analytical chemistry attributes has been developed. The new tool, called GAPI (Green Analytical Procedure Index), evaluates the green character of an entire analytical methodology, from sample collection to final determination, and was created using such tools as the National Environmental Methods Index (NEMI) or Analytical Eco-Scale to provide not only general but also qualitative information. In GAPI, a specific symbol with five pentagrams can be used to evaluate and quantify the environmental impact involved in each step of an analytical methodology, mainly from green through yellow to red depicting low, medium to high impact, respectively. The proposed tool was used to evaluate analytical procedures applied in the determination of biogenic amines in wine samples, and polycyclic aromatic hydrocarbon determination by EPA methods. GAPI tool not only provides an immediately perceptible perspective to the user/reader but also offers exhaustive information on evaluated procedures. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Processing a Complex Architectural Sampling with Meshlab: the Case of Piazza della Signoria

    Science.gov (United States)

    Callieri, M.; Cignoni, P.; Dellepiane, M.; Ranzuglia, G.; Scopigno, R.

    2011-09-01

    The paper presents a recent 3D scanning project performed with long range scanning technology showing how a complex sampled dataset can be processed with the features available in MeshLab, an open source tool. MeshLab is an open source mesh processing system. It is a portable and extensible system aimed to help the processing of the typical not-so-small unstructured models that arise in 3D scanning, providing a set of tools for editing, cleaning, processing, inspecting, rendering and converting meshes. The MeshLab system started in late 2005 as a part of a university course, and considerably evolved since then thanks to the effort of the Visual Computing Lab and of the support of several funded EC projects. MeshLab gained so far an excellent visibility and distribution, with several thousands downloads every month, and a continuous evolution. The aim of this scanning campaign was to sample the façades of the buildings located in Piazza della Signoria (Florence, Italy). This digital 3D model was required, in the framework of a Regional Project, as a basic background model to present a complex set of images using a virtual navigation metaphor (following the PhotoSynth approach). Processing of complex dataset, such as the ones produced by long range scanners, often requires specialized, difficult to use and costly software packages. We show in the paper how it is possible to process this kind of data inside an open source tool, thanks to the many new features recently introduced in MeshLab for the management of large sets of sampled point.

  5. A mixed signal ECG processing platform with an adaptive sampling ADC for portable monitoring applications.

    Science.gov (United States)

    Kim, Hyejung; Van Hoof, Chris; Yazicioglu, Refet Firat

    2011-01-01

    This paper describes a mixed-signal ECG processing platform with an 12-bit ADC architecture that can adapt its sampling rate according to the input signals rate of change. This enables the sampling of ECG signals with significantly reduced data rate without loss of information. The presented adaptive sampling scheme reduces the ADC power consumption, enables the processing of ECG signals with lower power consumption, and reduces the power consumption of the radio while streaming the ECG signals. The test results show that running a CWT-based R peak detection algorithm using the adaptively sampled ECG signals consumes only 45.6 μW and it leads to 36% less overall system power consumption.

  6. A Guide for Developing Standard Operating Job Procedures for the Tertiary Chemical Treatment - Lime Precipitation Process Wastewater Treatment Facility. SOJP No. 6.

    Science.gov (United States)

    Petrasek, Al, Jr.

    This guide describes the standard operating job procedures for the tertiary chemical treatment - lime precipitation process of wastewater treatment plants. Step-by-step instructions are given for pre-start up, start-up, continuous operation, and shut-down procedures. In addition, some theoretical material is presented along with some relevant…

  7. Soil sampling

    International Nuclear Information System (INIS)

    Fortunati, G.U.; Banfi, C.; Pasturenzi, M.

    1994-01-01

    This study attempts to survey the problems associated with techniques and strategies of soil sampling. Keeping in mind the well defined objectives of a sampling campaign, the aim was to highlight the most important aspect of representativeness of samples as a function of the available resources. Particular emphasis was given to the techniques and particularly to a description of the many types of samplers which are in use. The procedures and techniques employed during the investigations following the Seveso accident are described. (orig.)

  8. Long Term Resource Monitoring Program procedures: fish monitoring

    Science.gov (United States)

    Ratcliff, Eric N.; Glittinger, Eric J.; O'Hara, T. Matt; Ickes, Brian S.

    2014-01-01

    This manual constitutes the second revision of the U.S. Army Corps of Engineers’ Upper Mississippi River Restoration-Environmental Management Program (UMRR-EMP) Long Term Resource Monitoring Program (LTRMP) element Fish Procedures Manual. The original (1988) manual merged and expanded on ideas and recommendations related to Upper Mississippi River fish sampling presented in several early documents. The first revision to the manual was made in 1995 reflecting important protocol changes, such as the adoption of a stratified random sampling design. The 1995 procedures manual has been an important document through the years and has been cited in many reports and scientific manuscripts. The resulting data collected by the LTRMP fish component represent the largest dataset on fish within the Upper Mississippi River System (UMRS) with more than 44,000 collections of approximately 5.7 million fish. The goal of this revision of the procedures manual is to document changes in LTRMP fish sampling procedures since 1995. Refinements to sampling methods become necessary as monitoring programs mature. Possible refinements are identified through field experiences (e.g., sampling techniques and safety protocols), data analysis (e.g., planned and studied gear efficiencies and reallocations of effort), and technological advances (e.g., electronic data entry). Other changes may be required because of financial necessity (i.e., unplanned effort reductions). This version of the LTRMP fish monitoring manual describes the most current (2014) procedures of the LTRMP fish component.

  9. Radiochemical procedures and techniques

    International Nuclear Information System (INIS)

    Flynn, K.

    1975-04-01

    A summary is presented of the radiochemical procedures and techniques currently in use by the Chemistry Division Nuclear Chemistry Group at Argonne National Laboratory for the analysis of radioactive samples. (U.S.)

  10. A novel approach to process carbonate samples for radiocarbon measurements with helium carrier gas

    Energy Technology Data Exchange (ETDEWEB)

    Wacker, L., E-mail: wacker@phys.ethz.ch [Laboratory of Ion Beam Physics, ETH Zurich, 8093 Zurich (Switzerland); Fueloep, R.-H. [Institute of Geology and Mineralogy, University of Cologne, 50674 Cologne (Germany); Hajdas, I. [Laboratory of Ion Beam Physics, ETH Zurich, 8093 Zurich (Switzerland); Molnar, M. [Laboratory of Ion Beam Physics, ETH Zurich, 8093 Zurich (Switzerland); Institute of Nuclear Research, Hungarian Academy of Sciences, 4026 Debrecen (Hungary); Rethemeyer, J. [Institute of Geology and Mineralogy, University of Cologne, 50674 Cologne (Germany)

    2013-01-15

    Most laboratories prepare carbonates samples for radiocarbon analysis by acid decomposition in evacuated glass tubes and subsequent reduction of the evolved CO{sub 2} to graphite in self-made reduction manifolds. This process is time consuming and labor intensive. In this work, we have tested a new approach for the preparation of carbonate samples, where any high-vacuum system is avoided and helium is used as a carrier gas. The liberation of CO{sub 2} from carbonates with phosphoric acid is performed in a similar way as it is often done in stable isotope ratio mass spectrometry where CO{sub 2} is released with acid in septum sealed tube under helium atmosphere. The formed CO{sub 2} is later flushed in a helium flow by means of a double-walled needle mounted from the tubes to the zeolite trap of the automated graphitization equipment (AGE). It essentially replaces the elemental analyzer normally used for the combustion of organic samples. The process can be fully automated from sampling the released CO{sub 2} in the septum-sealed tubes with a commercially available auto-sampler to the graphitization with the automated graphitization. The new method yields in low sample blanks of about 50000 years. Results of processed reference materials (IAEA-C2, FIRI-C) are in agreement with their consensus values.

  11. Attributional and relational processing in pigeons

    Directory of Open Access Journals (Sweden)

    Dennis eGarlick

    2011-02-01

    Full Text Available Six pigeons were trained using a matching-to-sample procedure where sample and rewarded comparisons matched on both attributional (color and relational (horizontal or vertical orientation dimensions. Probes then evaluated the pigeons’ preference to comparisons that varied in these dimensions. A strong preference was found for the attribute of color. The discrimination was not found to transfer to novel colors, however, suggesting that a general color rule had not been learned. Further, when color could not be used to guide responding, some influence of other attributional cues such as shape, but not relational cues, was found. We conclude that pigeons based their performance on attributional properties of but not on relational properties between elements in our matching-to-sample procedure.. Future studies should look at examining other attributes to compare attributional versus relational processing.

  12. Handling of radiopharmaceuticals drugs in hot cell: Implementation and validation of new hygiene procedures

    International Nuclear Information System (INIS)

    Levigoureux, E.; Hoffman, A.; Bolot, C.; Aulagner, G.; Brun, J.

    2012-01-01

    Exigencies associated with radiopharmaceutical drugs require validation of hygiene procedures. Different bio-cleaning processes were applied. For each, samples were collected from work surface, from preparation field and from the cap of multi-doses vial on agar contact. Twenty-two radiopharmaceutical preparations were inoculated in different liquid media. Results show that modification of bio-cleaning process enables a microbiological contamination reduction (p ≡ 0.0196). All preparations passed the sterility tests. Thus these results enabled the validation of new hygiene process in the radiopharmacy unit. (authors) [fr

  13. Electrochemical detection of a powerful estrogenic endocrine disruptor: ethinylestradiol in water samples through bioseparation procedure.

    Science.gov (United States)

    Martínez, Noelia A; Pereira, Sirley V; Bertolino, Franco A; Schneider, Rudolf J; Messina, Germán A; Raba, Julio

    2012-04-20

    The synthetic estrogen ethinylestradiol (EE2) is an active component of oral contraceptives (OCs), considered as an endocrine disrupting compound (EDC). It is excreted from humans and released via sewage treatment plant effluents into aquatic environments. EDCs are any environmental pollutant chemical that, once incorporated into an organism, affects the hormonal balance of various species including humans. Its presence in the environment is becoming of great importance in water quality. This paper describes the development of an accurate, sensitive and selective method for capture, preconcentration and determination of EE2 present in water samples using: magnetic particles (MPs) as bioaffinity support for the capture and preconcentration of EE2 and a glassy carbon electrode modified with multi-walled carbon nanotubes (MWCNTs/GCE) as detection system. The capture procedure was based on the principle of immunoaffinity, the EE2 being extracted from the sample using the anti-EE2 antibodies (anti-EE2 Ab) which were previously immobilized on MPs. Subsequently the analyte desorption was done employing a sulfuric acid solution and the determination of the EE2 in the pre-concentrated solution was carried out by square wave voltammetry (SWV). This method can be used to determine EE2 in the range of 0.035-70 ng L(-1) with a detection limit (LOD) of 0.01 ng L(-1) and R.S.D.levels. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Automated processing of forensic casework samples using robotic workstations equipped with nondisposable tips: contamination prevention.

    Science.gov (United States)

    Frégeau, Chantal J; Lett, C Marc; Elliott, Jim; Yensen, Craig; Fourney, Ron M

    2008-05-01

    An automated process has been developed for the analysis of forensic casework samples using TECAN Genesis RSP 150/8 or Freedom EVO liquid handling workstations equipped exclusively with nondisposable tips. Robot tip cleaning routines have been incorporated strategically within the DNA extraction process as well as at the end of each session. Alternative options were examined for cleaning the tips and different strategies were employed to verify cross-contamination. A 2% sodium hypochlorite wash (1/5th dilution of the 10.8% commercial bleach stock) proved to be the best overall approach for preventing cross-contamination of samples processed using our automated protocol. The bleach wash steps do not adversely impact the short tandem repeat (STR) profiles developed from DNA extracted robotically and allow for major cost savings through the implementation of fixed tips. We have demonstrated that robotic workstations equipped with fixed pipette tips can be used with confidence with properly designed tip washing routines to process casework samples using an adapted magnetic bead extraction protocol.

  15. Developing Water Sampling Standards

    Science.gov (United States)

    Environmental Science and Technology, 1974

    1974-01-01

    Participants in the D-19 symposium on aquatic sampling and measurement for water pollution assessment were informed that determining the extent of waste water stream pollution is not a cut and dry procedure. Topics discussed include field sampling, representative sampling from storm sewers, suggested sampler features and application of improved…

  16. Procedures for Efficient and Economic Recovery of Heat for Reuse in Batch Processes for Cleaning

    DEFF Research Database (Denmark)

    Qvale, Einar Bjørn

    2005-01-01

    The expenditure of primary energy can be reduced and the economics of process plants in the food industry can be improved by intelligent application of Process Integration (PI). Since a greater part of the products in the food industry is processed in batches, the use of Thermal- Energy Storage...... are often encountered in the food industry. However, the extent to which PI is utilized is much smaller than the number of potential applications. The present paper will address this topic, give some reasons for the underuse of PI, and indicate some principles, methods, and directions that, when applied......, could increase the use and usefulness of PI by incorporating TES, thus fulfilling PI’s promises of improved operation, reduced energy consumption, reduced environmental impact, and improved economics. The application of these procedures is illustrated through the description of two cases. Keywords: Heat...

  17. Procedural generation of aesthetic patterns from dynamics and iteration processes

    Directory of Open Access Journals (Sweden)

    Gdawiec Krzysztof

    2017-12-01

    Full Text Available Aesthetic patterns are widely used nowadays, e.g., in jewellery design, carpet design, as textures and patterns on wallpapers, etc. Most of the work during the design stage is carried out by a designer manually. Therefore, it is highly useful to develop methods for aesthetic pattern generation. In this paper, we present methods for generating aesthetic patterns using the dynamics of a discrete dynamical system. The presented methods are based on the use of various iteration processes from fixed point theory (Mann, S, Noor, etc. and the application of an affine combination of these iterations. Moreover, we propose new convergence tests that enrich the obtained patterns. The proposed methods generate patterns in a procedural way and can be easily implemented on the GPU. The presented examples show that using the proposed methods we are able to obtain a variety of interesting patterns. Moreover, the numerical examples show that the use of the GPU implementation with shaders allows the generation of patterns in real time and the speed-up (compared with a CPU implementation ranges from about 1000 to 2500 times.

  18. How the Monte Carlo production of a wide variety of different samples is centrally handled in the LHCb experiment

    CERN Document Server

    Corti, G; Clemencic, M; Closier, J; Couturier, B; Kreps, M; Mathe, Z; O'Hanlon, D; Robbe, P; Romanovsky, V; Stagni, F; Zhelezov, A

    2015-01-01

    In the LHCb experiment a wide variety of Monte Carlo simulated samples needs to be produced for the experiment's physics program. Monte Carlo productions are handled centrally similarly to all massive processing of data in the experiment. In order to cope with the large set of different types of simulation samples, necessary procedures based on common infrastructures have been set up with a numerical event type identification code used throughout. The various elements in the procedure, from writing a configuration for an event type to deploying them on the production environment, from submitting and processing a request to retrieving the sample produced as well as the conventions established to allow their interplay will be described. The choices made have allowed a high level of automation of Monte Carlo productions that are handled centrally in a transparent way with experts concentrating on their specific tasks. As a result the massive Monte Carlo production of the experiment is efficiently processed on a ...

  19. Large sample hydrology in NZ: Spatial organisation in process diagnostics

    Science.gov (United States)

    McMillan, H. K.; Woods, R. A.; Clark, M. P.

    2013-12-01

    A key question in hydrology is how to predict the dominant runoff generation processes in any given catchment. This knowledge is vital for a range of applications in forecasting hydrological response and related processes such as nutrient and sediment transport. A step towards this goal is to map dominant processes in locations where data is available. In this presentation, we use data from 900 flow gauging stations and 680 rain gauges in New Zealand, to assess hydrological processes. These catchments range in character from rolling pasture, to alluvial plains, to temperate rainforest, to volcanic areas. By taking advantage of so many flow regimes, we harness the benefits of large-sample and comparative hydrology to study patterns and spatial organisation in runoff processes, and their relationship to physical catchment characteristics. The approach we use to assess hydrological processes is based on the concept of diagnostic signatures. Diagnostic signatures in hydrology are targeted analyses of measured data which allow us to investigate specific aspects of catchment response. We apply signatures which target the water balance, the flood response and the recession behaviour. We explore the organisation, similarity and diversity in hydrological processes across the New Zealand landscape, and how these patterns change with scale. We discuss our findings in the context of the strong hydro-climatic gradients in New Zealand, and consider the implications for hydrological model building on a national scale.

  20. The Development of Metabolomic Sampling Procedures for Pichia pastoris, and Baseline Metabolome Data

    Science.gov (United States)

    Tredwell, Gregory D.; Edwards-Jones, Bryn; Leak, David J.; Bundy, Jacob G.

    2011-01-01

    Metabolic profiling is increasingly being used to investigate a diverse range of biological questions. Due to the rapid turnover of intracellular metabolites it is important to have reliable, reproducible techniques for sampling and sample treatment. Through the use of non-targeted analytical techniques such as NMR and GC-MS we have performed a comprehensive quantitative investigation of sampling techniques for Pichia pastoris. It was clear that quenching metabolism using solutions based on the standard cold methanol protocol caused some metabolite losses from P. pastoris cells. However, these were at a low level, with the NMR results indicating metabolite increases in the quenching solution below 5% of their intracellular level for 75% of metabolites identified; while the GC-MS results suggest a slightly higher level with increases below 15% of their intracellular values. There were subtle differences between the four quenching solutions investigated but broadly, they all gave similar results. Total culture extraction of cells + broth using high cell density cultures typical of P. pastoris fermentations, was an efficient sampling technique for NMR analysis and provided a gold standard of intracellular metabolite levels; however, salts in the media affected the GC-MS analysis. Furthermore, there was no benefit in including an additional washing step in the quenching process, as the results were essentially identical to those obtained just by a single centrifugation step. We have identified the major high-concentration metabolites found in both the extra- and intracellular locations of P. pastoris cultures by NMR spectroscopy and GC-MS. This has provided us with a baseline metabolome for P. pastoris for future studies. The P. pastoris metabolome is significantly different from that of Saccharomyces cerevisiae, with the most notable difference being the production of high concentrations of arabitol by P. pastoris. PMID:21283710

  1. Water column velocimeter for NSRR experiment. Characteristics and data processing procedure

    International Nuclear Information System (INIS)

    Sugiyama, Tomoyuki; Fuketa, Toyoshi

    2000-11-01

    In order to clarify fuel behavior under reactivity initiated accident (RIA) conditions, pulse irradiation experiments on fuel rods are carried out in the Nuclear Safety Research Reactor (NSRR). One of concerns at fuel failure is mechanical energy generation in the reactor vessel. The mechanical energy is generated by a water hammer or a pressure impact occurred at fuel failure, and has possibility to damage reactor structures. Thus, the amount of generated mechanical energy is critical information for the safety evaluation of power reactor. In the NSRR experiments, the mechanical energy due to the water hammer is evaluated as the kinetic energy of the jumping water column at fuel failure, and the velocity of the water column is measured by the float type water column velocimeter. This report presents characteristics of the water column velocimeter and the procedure of data processing in the NSRR experiments. (author)

  2. Surface Environmental Surveillance Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    RW Hanf; TM Poston

    2000-09-20

    Environmental surveillance data are used in assessing the impact of current and past site operations on human health and the environment, demonstrating compliance with applicable local, state, and federal environmental regulations, and verifying the adequacy of containment and effluent controls. SESP sampling schedules are reviewed, revised, and published each calendar year in the Hanford Site Environmental Surveillance Master Sampling Schedule. Environmental samples are collected by SESP staff in accordance with the approved sample collection procedures documented in this manual.

  3. An Alternative View of Some FIA Sample Design and Analysis Issues

    Science.gov (United States)

    Paul C. Van Deusen

    2005-01-01

    Sample design and analysis decisions are the result of compromises and inputs from many sources. The end result would likely change if different individuals or groups were involved in the planning process. Discussed here are some alternatives to the procedures that are currently being used for the annual inventory. The purpose is to indicate that alternatives exist and...

  4. Sample preparation for semivolatile organics analysis of Hanford single-shell tank waste with high nitrate/nitrite and water content

    International Nuclear Information System (INIS)

    Stromatt, R.W.; Hoppe, E.W.; Steele, M.J.

    1993-11-01

    This report describes research work carried out to solve sample preparation problems associated with applying gas chromatography with mass spectrometric detection (GC/MS) to the analysis of single shell tank (SST) samples from Hanford for semivolatile organic compounds. Poor performance was found when applying the procedures based on the U.S. Environmental Protection Agency (EPA), Contract Laboratory Program, Statement of Work (CLP SOW). Analysis work was carried out on simulated drainable liquid modeled after the SST core samples which had evidenced analysis problems. Some work was also conducted on true SST samples. It was found that the pH range was too broad in the original procedure. It was also found that by decreasing the amount of methanol used in the extraction process, problems associated with the formation of an azeotrope phase could be avoided. The authors suggest a new procedure, whose eventual application to a wide array of SST samples will lend itself to better quality control limits

  5. Event Processing and Variable Part of Sample Period Determining in Combined Systems Using GA

    Science.gov (United States)

    Strémy, Maximilián; Závacký, Pavol; Jedlička, Martin

    2011-01-01

    This article deals with combined dynamic systems and usage of modern techniques in dealing with these systems, focusing particularly on sampling period design, cyclic processing tasks and related processing algorithms in the combined event management systems using genetic algorithms.

  6. Human factoring administrative procedures

    International Nuclear Information System (INIS)

    Grider, D.A.; Sturdivant, M.H.

    1991-01-01

    In nonnuclear business, administrative procedures bring to mind such mundane topics as filing correspondence and scheduling vacation time. In the nuclear industry, on the other hand, administrative procedures play a vital role in assuring the safe operation of a facility. For some time now, industry focus has been on improving technical procedures. Significant efforts are under way to produce technical procedure requires that a validated technical, regulatory, and administrative basis be developed and that the technical process be established for each procedure. Producing usable technical procedures requires that procedure presentation be engineered to the same human factors principles used in control room design. The vital safety role of administrative procedures requires that they be just as sound, just a rigorously formulated, and documented as technical procedures. Procedure programs at the Tennessee Valley Authority and at Boston Edison's Pilgrim Station demonstrate that human factors engineering techniques can be applied effectively to technical procedures. With a few modifications, those same techniques can be used to produce more effective administrative procedures. Efforts are under way at the US Department of Energy Nuclear Weapons Complex and at some utilities (Boston Edison, for instance) to apply human factors engineering to administrative procedures: The techniques being adapted include the following

  7. The Neural Correlates of Implicit and Explicit Sequence Learning: Interacting Networks Revealed by the Process Dissociation Procedure

    Science.gov (United States)

    Laureys, Steven; Degueldre, Christian; Del Fiore, Guy; Aerts, Joel; Luxen, Andre; Van Der Linden, Martial; Cleeremans, Axel; Maquet, Pierre; Destrebecqz, Arnaud; Peigneux, Philippe

    2005-01-01

    In two H[subscript 2] [superscript 15]O PET scan experiments, we investigated the cerebral correlates of explicit and implicit knowledge in a serial reaction time (SRT) task. To do so, we used a novel application of the Process Dissociation Procedure, a behavioral paradigm that makes it possible to separately assess conscious and unconscious…

  8. Sampling phased array - a new technique for ultrasonic signal processing and imaging

    OpenAIRE

    Verkooijen, J.; Boulavinov, A.

    2008-01-01

    Over the past 10 years, the improvement in the field of microelectronics and computer engineering has led to significant advances in ultrasonic signal processing and image construction techniques that are currently being applied to non-destructive material evaluation. A new phased array technique, called 'Sampling Phased Array', has been developed in the Fraunhofer Institute for Non-Destructive Testing([1]). It realises a unique approach of measurement and processing of ultrasonic signals. Th...

  9. Developing Conceptual Understanding and Procedural Skill in Mathematics: An Iterative Process.

    Science.gov (United States)

    Rittle-Johnson, Bethany; Siegler, Robert S.; Alibali, Martha Wagner

    2001-01-01

    Proposes that conceptual and procedural knowledge develop in an iterative fashion and improved problem representation is one mechanism underlying the relations between them. Two experiments were conducted with 5th and 6th grade students learning about decimal fractions. Results indicate conceptual and procedural knowledge do develop, iteratively,…

  10. Improved Detection of Extended Spectrum Beta-Lactamase (ESBL)-Producing Escherichia coli in Input and Output Samples of German Biogas Plants by a Selective Pre-Enrichment Procedure

    Science.gov (United States)

    Schauss, Thorsten; Glaeser, Stefanie P.; Gütschow, Alexandra; Dott, Wolfgang; Kämpfer, Peter

    2015-01-01

    The presence of extended-spectrum beta-lactamase (ESBL)-producing Escherichia coli was investigated in input (manure from livestock husbandry) and output samples of six German biogas plants in 2012 (one sampling per biogas plant) and two German biogas plants investigated in an annual cycle four times in 2013/2014. ESBL-producing Escherichia coli were cultured by direct plating on CHROMagar ESBL from input samples in the range of 100 to 104 colony forming units (CFU) per g dry weight but not from output sample. This initially indicated a complete elimination of ESBL-producing E. coli by the biogas plant process. Detected non target bacteria were assigned to the genera Acinetobacter, Pseudomonas, Bordetella, Achromobacter, Castellaniella, and Ochrobactrum. A selective pre-enrichment procedure increased the detection efficiency of ESBL-producing E. coli in input samples and enabled the detection in five of eight analyzed output samples. In total 119 ESBL-producing E. coli were isolated from input and 46 from output samples. Most of the E. coli isolates carried CTX-M-type and/or TEM-type beta lactamases (94%), few SHV-type beta lactamase (6%). Sixty-four bla CTX-M genes were characterized more detailed and assigned mainly to CTX-M-groups 1 (85%) and 9 (13%), and one to group 2. Phylogenetic grouping of 80 E. coli isolates showed that most were assigned to group A (71%) and B1 (27%), only one to group D (2%). Genomic fingerprinting and multilocus sequence typing (MLST) showed a high clonal diversity with 41 BOX-types and 19 ST-types. The two most common ST-types were ST410 and ST1210. Antimicrobial susceptibility testing of 46 selected ESBL-producing E. coli revealed that several isolates were additionally resistant to other veterinary relevant antibiotics and some grew on CHROMagar STEC but shiga-like toxine (SLT) genes were not detected. Resistance to carbapenems was not detected. In summary the study showed for the first time the presence of ESBL-producing E. coli in

  11. Improved detection of extended spectrum beta-lactamase (ESBL-producing Escherichia coli in input and output samples of German biogas plants by a selective pre-enrichment procedure.

    Directory of Open Access Journals (Sweden)

    Thorsten Schauss

    Full Text Available The presence of extended-spectrum beta-lactamase (ESBL-producing Escherichia coli was investigated in input (manure from livestock husbandry and output samples of six German biogas plants in 2012 (one sampling per biogas plant and two German biogas plants investigated in an annual cycle four times in 2013/2014. ESBL-producing Escherichia coli were cultured by direct plating on CHROMagar ESBL from input samples in the range of 100 to 104 colony forming units (CFU per g dry weight but not from output sample. This initially indicated a complete elimination of ESBL-producing E. coli by the biogas plant process. Detected non target bacteria were assigned to the genera Acinetobacter, Pseudomonas, Bordetella, Achromobacter, Castellaniella, and Ochrobactrum. A selective pre-enrichment procedure increased the detection efficiency of ESBL-producing E. coli in input samples and enabled the detection in five of eight analyzed output samples. In total 119 ESBL-producing E. coli were isolated from input and 46 from output samples. Most of the E. coli isolates carried CTX-M-type and/or TEM-type beta lactamases (94%, few SHV-type beta lactamase (6%. Sixty-four blaCTX-M genes were characterized more detailed and assigned mainly to CTX-M-groups 1 (85% and 9 (13%, and one to group 2. Phylogenetic grouping of 80 E. coli isolates showed that most were assigned to group A (71% and B1 (27%, only one to group D (2%. Genomic fingerprinting and multilocus sequence typing (MLST showed a high clonal diversity with 41 BOX-types and 19 ST-types. The two most common ST-types were ST410 and ST1210. Antimicrobial susceptibility testing of 46 selected ESBL-producing E. coli revealed that several isolates were additionally resistant to other veterinary relevant antibiotics and some grew on CHROMagar STEC but shiga-like toxine (SLT genes were not detected. Resistance to carbapenems was not detected. In summary the study showed for the first time the presence of ESBL-producing E

  12. Robowell: An automated process for monitoring ground water quality using established sampling protocols

    Science.gov (United States)

    Granato, G.E.; Smith, K.P.

    1999-01-01

    Robowell is an automated process for monitoring selected ground water quality properties and constituents by pumping a well or multilevel sampler. Robowell was developed and tested to provide a cost-effective monitoring system that meets protocols expected for manual sampling. The process uses commercially available electronics, instrumentation, and hardware, so it can be configured to monitor ground water quality using the equipment, purge protocol, and monitoring well design most appropriate for the monitoring site and the contaminants of interest. A Robowell prototype was installed on a sewage treatment plant infiltration bed that overlies a well-studied unconfined sand and gravel aquifer at the Massachusetts Military Reservation, Cape Cod, Massachusetts, during a time when two distinct plumes of constituents were released. The prototype was operated from May 10 to November 13, 1996, and quality-assurance/quality-control measurements demonstrated that the data obtained by the automated method was equivalent to data obtained by manual sampling methods using the same sampling protocols. Water level, specific conductance, pH, water temperature, dissolved oxygen, and dissolved ammonium were monitored by the prototype as the wells were purged according to U.S Geological Survey (USGS) ground water sampling protocols. Remote access to the data record, via phone modem communications, indicated the arrival of each plume over a few days and the subsequent geochemical reactions over the following weeks. Real-time availability of the monitoring record provided the information needed to initiate manual sampling efforts in response to changes in measured ground water quality, which proved the method and characterized the screened portion of the plume in detail through time. The methods and the case study described are presented to document the process for future use.

  13. A headspace solid-phase microextraction procedure coupled with gas chromatography-mass spectrometry for the analysis of volatile polycyclic aromatic hydrocarbons in milk samples

    Energy Technology Data Exchange (ETDEWEB)

    Aguinaga, N.; Campillo, N.; Vinas, P.; Hernandez-Cordoba, M. [University of Murcia, Department of Analytical Chemistry, Faculty of Chemistry, Murcia (Spain)

    2008-06-15

    A sensitive and solvent-free method for the determination of ten polycyclic aromatic hydrocarbons, namely, naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo[a]anthracene and chrysene, with up to four aromatic rings, in milk samples using headspace solid-phase microextraction and gas chromatography-mass spectrometry detection has been developed. A polydimethylsiloxane-divinylbenzene fiber was chosen and used at 75 C for 60 min. Detection limits ranging from 0.2 to 5 ng L{sup -1} were attained at a signal-to-noise ratio of 3, depending on the compound and the milk sample under analysis. The proposed method was applied to ten different milk samples and the presence of six of the analytes studied in a skimmed milk with vegetal fiber sample was confirmed. The reliability of the procedure was verified by analyzing two different certified reference materials and by recovery studies. (orig.)

  14. Implementation of procedures to NPP Krsko INTRANEK

    International Nuclear Information System (INIS)

    Gradisar, D.; Krajnc, M.; Kocnar, R.; Spiler, J.

    1999-01-01

    Part of NEK documentation has already been presented on NEK Intranet such as USAR, Technical Specifications, QA Plan as well as some frequently used series of drawings. At the time being the process of presentation of all procedures (thereinafter INTRANEK procedures) is in progress. The purpose of this project is the presentation of 1600 procedures with average size of 30 pages what is more than 48000 pages altogether. ADOBE PDF (Portable Document Format) has been chosen as the most suitable format for the presentation of procedures on INTRANEK. PDF format meets the following criteria: the outlook of a document page is always the same as an original one and cannot be changed without control. In addition to this, full text search is available as well as easy jump from procedure to procedure. Some changes of working process on internal procedures have to be made before the project start, which determine the responsibility of individual users in the process. The work flow, which enables easy daily maintenance, has been prepared, the rules of both procedure numbering as well as folder contents/name have been set and the server selected. The project was managed and implemented with the extensive use of compute-aided management, document distribution and control, databases, electronics mail and Intranet tools. The results of practical implementation of NEK procedures and our experience with INTRANEK are presented in this paper.(author)

  15. Quality demonstration of analytica procedure for quantification of 134Cesium and 137Cesium in water samples

    International Nuclear Information System (INIS)

    Santos, T.O.; Farias, E.E.G.; Filho, C.A.S.; França, E.J. de

    2017-01-01

    Intercomparison programs are extremely important in attesting the metrological quality of laboratories, contributing to the improvement of the quality of the analytical procedures adopted and the validation of new analytical methodologies. The objective of this work is to demonstrate the quality of the analyzes of radionuclides Cs-134 and Cs-137 by High Resolution Gamma Spectrometry in water samples of the PNI (National Intercomparison Program). Prior to the start of the analyzes, the vials containing the concentrated samples are shaken for about 10 minutes to ensure homogeneity. A 500 ml aliquot of the concentrated solution is transferred to a beaker for dilution with 1% (v / v) HNO 3 to 4 liters. After being shaken for 30 minutes, 2 liters of this diluted solution are transferred to a Marinelli vessel and then analyzed by High Resolution Gamma Spectrometry (EGAR) using germanium Hyperpure-HPGe detectors. The results obtained are reported to the IRD for analytical performance evaluation. Based on the intercomparison rounds as of year 2011, the SEAMB/CRCN/NE (Environmental Monitoring Service of the Regional Center of Nuclear Sciences of the Northeast) participated in eight rounds of the PNI. All results were within the range of standard deviation evaluation parameter calculated by the IRD. The results obtained demonstrate the analytical capacity of the CRCN-NE for radiometric analyzes in water

  16. The Conciliation in the State Demands as an Alternative for the Economy in the Process in New Civil Procedure Code

    Directory of Open Access Journals (Sweden)

    Eduardo Augusto Salomão Camb

    2016-12-01

    Full Text Available The present study deals with the possibility of conciliation in the demands that involve the Public Power, having as main objective the procedural economy, both as regards the faster process, as to reduction of expenses with the structure of the Judiciary. Despite of the unavailability of the public interest, seeks out the adequacy of this principle with the principles in the New Civil Procedure Code, which encourages conciliation as a means of settling disputes.

  17. Determination of drugs in biological fluids by high-performance liquid chromatography with on-line sample processing.

    Science.gov (United States)

    Oertel, R; Richter, K; Gramatté, T; Kirch, W

    1998-02-27

    An automated two column HPLC system with the new packing material LiChrospher RP-18 ADS (alkyl-diol-silica) was tested for the determination of several drugs and metabolites (talinolol, celiprolol, metoprolol, oxprenolol, triamterene, trimethoprim, tiracizine, articaine, detajmium, ajmaline, lamotrigine) in various biological fluids (serum, urine, intestinal aspirates, supernatants of cell cultures and supernatants after protein denaturation). The method allows the direct injection of biological fluids into a reversed-phase HPLC system and on-line clean-up and sample enrichment by a column-switching technique. Precision, accuracy and sensitivity were similar to conventional assays as described in the literature. With this new method it was possible to measure drug concentrations in various biological fluids without changing the sample preparation procedure. In some cases an additional sample preparation like protein denaturation or solid-phase extraction was advantageous to enhance the sensitivity of the method and the life-time of the ADS column.

  18. 40 CFR 53.43 - Test procedures.

    Science.gov (United States)

    2010-07-01

    ... sampling zone (see § 53.42(d)). To meet the maximum blockage limit of § 53.42(a) or for convenience, part... PM10 § 53.43 Test procedures. (a) Sampling effectiveness—(1) Technical definition. The ratio (expressed... evenly spaced isokinetic samplers in the sampling zone (see § 53.42(d)) of the wind tunnel. Collect...

  19. 40 CFR 1065.150 - Continuous sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Continuous sampling. 1065.150 Section... ENGINE-TESTING PROCEDURES Equipment Specifications § 1065.150 Continuous sampling. You may use continuous sampling techniques for measurements that involve raw or dilute sampling. Make sure continuous sampling...

  20. Bilateral capacity for speech sound processing in auditory comprehension: evidence from Wada procedures.

    Science.gov (United States)

    Hickok, G; Okada, K; Barr, W; Pa, J; Rogalsky, C; Donnelly, K; Barde, L; Grant, A

    2008-12-01

    Data from lesion studies suggest that the ability to perceive speech sounds, as measured by auditory comprehension tasks, is supported by temporal lobe systems in both the left and right hemisphere. For example, patients with left temporal lobe damage and auditory comprehension deficits (i.e., Wernicke's aphasics), nonetheless comprehend isolated words better than one would expect if their speech perception system had been largely destroyed (70-80% accuracy). Further, when comprehension fails in such patients their errors are more often semantically-based, than-phonemically based. The question addressed by the present study is whether this ability of the right hemisphere to process speech sounds is a result of plastic reorganization following chronic left hemisphere damage, or whether the ability exists in undamaged language systems. We sought to test these possibilities by studying auditory comprehension in acute left versus right hemisphere deactivation during Wada procedures. A series of 20 patients undergoing clinically indicated Wada procedures were asked to listen to an auditorily presented stimulus word, and then point to its matching picture on a card that contained the target picture, a semantic foil, a phonemic foil, and an unrelated foil. This task was performed under three conditions, baseline, during left carotid injection of sodium amytal, and during right carotid injection of sodium amytal. Overall, left hemisphere injection led to a significantly higher error rate than right hemisphere injection. However, consistent with lesion work, the majority (75%) of these errors were semantic in nature. These findings suggest that auditory comprehension deficits are predominantly semantic in nature, even following acute left hemisphere disruption. This, in turn, supports the hypothesis that the right hemisphere is capable of speech sound processing in the intact brain.