WorldWideScience

Sample records for sample preparation prior

  1. Implementation of antimicrobial peptides for sample preparation prior to nucleic acid amplification in point-of-care settings.

    Science.gov (United States)

    Krõlov, Katrin; Uusna, Julia; Grellier, Tiia; Andresen, Liis; Jevtuševskaja, Jekaterina; Tulp, Indrek; Langel, Ülo

    2017-12-01

    A variety of sample preparation techniques are used prior to nucleic acid amplification. However, their efficiency is not always sufficient and nucleic acid purification remains the preferred method for template preparation. Purification is difficult and costly to apply in point-of-care (POC) settings and there is a strong need for more robust, rapid, and efficient biological sample preparation techniques in molecular diagnostics. Here, the authors applied antimicrobial peptides (AMPs) for urine sample preparation prior to isothermal loop-mediated amplification (LAMP). AMPs bind to many microorganisms such as bacteria, fungi, protozoa and viruses causing disruption of their membrane integrity and facilitate nucleic acid release. The authors show that incubation of E. coli with antimicrobial peptide cecropin P1 for 5 min had a significant effect on the availability of template DNA compared with untreated or even heat treated samples resulting in up to six times increase of the amplification efficiency. These results show that AMPs treatment is a very efficient sample preparation technique that is suitable for application prior to nucleic acid amplification directly within biological samples. Furthermore, the entire process of AMPs treatment was performed at room temperature for 5 min thereby making it a good candidate for use in POC applications.

  2. Sample preparation prior to the LC-MS-based metabolomics/metabonomics of blood-derived samples.

    Science.gov (United States)

    Gika, Helen; Theodoridis, Georgios

    2011-07-01

    Blood represents a very important biological fluid and has been the target of continuous and extensive research for diagnostic, or health and drug monitoring reasons. Recently, metabonomics/metabolomics have emerged as a new and promising 'omics' platform that shows potential in biomarker discovery, especially in areas such as disease diagnosis, assessment of drug efficacy or toxicity. Blood is collected in various establishments in conditions that are not standardized. Next, the samples are prepared and analyzed using different methodologies or tools. When targeted analysis of key molecules (e.g., a drug or its metabolite[s]) is the aim, enforcement of certain measures or additional analyses may correct and harmonize these discrepancies. In omics fields such as those performed by holistic analytical approaches, no such rules or tools are available. As a result, comparison or correlation of results or data fusion becomes impractical. However, it becomes evident that such obstacles should be overcome in the near future to allow for large-scale studies that involve the assaying of samples from hundreds of individuals. In this case the effect of sample handling and preparation becomes very serious, in order to avoid wasting months of work from experts and expensive instrument time. The present review aims to cover the different methodologies applied to the pretreatment of blood prior to LC-MS metabolomic/metabonomic studies. The article tries to critically compare the methods and highlight issues that need to be addressed.

  3. Green approaches in sample preparation of bioanalytical samples prior to chromatographic analysis.

    Science.gov (United States)

    Filippou, Olga; Bitas, Dimitrios; Samanidou, Victoria

    2017-02-01

    Sample preparation is considered to be the most challenging step of the analytical procedure, since it has an effect on the whole analytical methodology, therefore it contributes significantly to the greenness or lack of it of the entire process. The elimination of the sample treatment steps, pursuing at the same time the reduction of the amount of the sample, strong reductions in consumption of hazardous reagents and energy also maximizing safety for operators and environment, the avoidance of the use of big amount of organic solvents, form the basis for greening sample preparation and analytical methods. In the last decade, the development and utilization of greener and sustainable microextraction techniques is an alternative to classical sample preparation procedures. In this review, the main green microextraction techniques (solid phase microextraction, stir bar sorptive extraction, hollow-fiber liquid phase microextraction, dispersive liquid - liquid microextraction, etc.) will be presented, with special attention to bioanalytical applications of these environment-friendly sample preparation techniques which comply with the green analytical chemistry principles. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Sample preparation

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Sample preparation prior to HPLC analysis is certainly one of the most important steps to consider in trace or ultratrace analysis. For many years scientists have tried to simplify the sample preparation process. It is rarely possible to inject a neat liquid sample or a sample where preparation may not be any more complex than dissolution of the sample in a given solvent. The last process alone can remove insoluble materials, which is especially helpful with the samples in complex matrices if other interactions do not affect extraction. Here, it is very likely a large number of components will not dissolve and are, therefore, eliminated by a simple filtration process. In most cases, the process of sample preparation is not as simple as dissolution of the component interest. At times, enrichment is necessary, that is, the component of interest is present in very large volume or mass of material. It needs to be concentrated in some manner so a small volume of the concentrated or enriched sample can be injected into HPLC. 88 refs

  5. pH adjustment of human blood plasma prior to bioanalytical sample preparation

    NARCIS (Netherlands)

    Hendriks, G.; Uges, D. R. A.; Franke, J. P.

    2008-01-01

    pH adjustment in bioanalytical sample preparation concerning ionisable compounds is one of the most common sample treatments. This is often done by mixing an aliquot of the sample with a proper buffer adjusted to the proposed pH. The pH of the resulting mixture however, does not necessarily have to

  6. On the development of automatic sample preparation devices

    International Nuclear Information System (INIS)

    Oesselmann, J.

    1987-01-01

    Modern mass spectrometers for stable isotope analysis offer accurate isotope ratio results from gaseous samples (CO 2 , N 2 , H 2 , SO 2 ) in a completely automated fashion. However, most samples of interest either are associated with contaminant gases or the gas has to be liberated by a chemical procedure prior to measurement. In most laboratories this sample preparation step is performed manually. As a consequence, sample throughput is rather low and - despite skilful operation - the preparation procedure varies slightly from one sample to the next affecting mainly the reproducibility of the data. (author)

  7. Sample preparation strategies for food and biological samples prior to nanoparticle detection and imaging

    DEFF Research Database (Denmark)

    Larsen, Erik Huusfeldt; Löschner, Katrin

    2014-01-01

    microscopy (TEM) proved to be necessary for trouble shooting of results obtained from AFFF-LS-ICP-MS. Aqueous and enzymatic extraction strategies were tested for thorough sample preparation aiming at degrading the sample matrix and to liberate the AgNPs from chicken meat into liquid suspension. The resulting...... AFFF-ICP-MS fractograms, which corresponded to the enzymatic digests, showed a major nano-peak (about 80 % recovery of AgNPs spiked to the meat) plus new smaller peaks that eluted close to the void volume of the fractograms. Small, but significant shifts in retention time of AFFF peaks were observed...... for the meat sample extracts and the corresponding neat AgNP suspension, and rendered sizing by way of calibration with AgNPs as sizing standards inaccurate. In order to gain further insight into the sizes of the separated AgNPs, or their possible dissolved state, fractions of the AFFF eluate were collected...

  8. Automated Blood Sample Preparation Unit (ABSPU) for Portable Microfluidic Flow Cytometry.

    Science.gov (United States)

    Chaturvedi, Akhil; Gorthi, Sai Siva

    2017-02-01

    Portable microfluidic diagnostic devices, including flow cytometers, are being developed for point-of-care settings, especially in conjunction with inexpensive imaging devices such as mobile phone cameras. However, two pervasive drawbacks of these have been the lack of automated sample preparation processes and cells settling out of sample suspensions, leading to inaccurate results. We report an automated blood sample preparation unit (ABSPU) to prevent blood samples from settling in a reservoir during loading of samples in flow cytometers. This apparatus automates the preanalytical steps of dilution and staining of blood cells prior to microfluidic loading. It employs an assembly with a miniature vibration motor to drive turbulence in a sample reservoir. To validate performance of this system, we present experimental evidence demonstrating prevention of blood cell settling, cell integrity, and staining of cells prior to flow cytometric analysis. This setup is further integrated with a microfluidic imaging flow cytometer to investigate cell count variability. With no need for prior sample preparation, a drop of whole blood can be directly introduced to the setup without premixing with buffers manually. Our results show that integration of this assembly with microfluidic analysis provides a competent automation tool for low-cost point-of-care blood-based diagnostics.

  9. Optimization of Sample Preparation processes of Bone Material for Raman Spectroscopy.

    Science.gov (United States)

    Chikhani, Madelen; Wuhrer, Richard; Green, Hayley

    2018-03-30

    Raman spectroscopy has recently been investigated for use in the calculation of postmortem interval from skeletal material. The fluorescence generated by samples, which affects the interpretation of Raman data, is a major limitation. This study compares the effectiveness of two sample preparation techniques, chemical bleaching and scraping, in the reduction of fluorescence from bone samples during testing with Raman spectroscopy. Visual assessment of Raman spectra obtained at 1064 nm excitation following the preparation protocols indicates an overall reduction in fluorescence. Results demonstrate that scraping is more effective at resolving fluorescence than chemical bleaching. The scraping of skeletonized remains prior to Raman analysis is a less destructive method and allows for the preservation of a bone sample in a state closest to its original form, which is beneficial in forensic investigations. It is recommended that bone scraping supersedes chemical bleaching as the preferred method for sample preparation prior to Raman spectroscopy. © 2018 American Academy of Forensic Sciences.

  10. Minimizing technical variation during sample preparation prior to label-free quantitative mass spectrometry.

    Science.gov (United States)

    Scheerlinck, E; Dhaenens, M; Van Soom, A; Peelman, L; De Sutter, P; Van Steendam, K; Deforce, D

    2015-12-01

    Sample preparation is the crucial starting point to obtain high-quality mass spectrometry data and can be divided into two main steps in a bottom-up proteomics approach: cell/tissue lysis with or without detergents and a(n) (in-solution) digest comprising denaturation, reduction, alkylation, and digesting of the proteins. Here, some important considerations, among others, are that the reagents used for sample preparation can inhibit the digestion enzyme (e.g., 0.1% sodium dodecyl sulfate [SDS] and 0.5 M guanidine HCl), give rise to ion suppression (e.g., polyethylene glycol [PEG]), be incompatible with liquid chromatography-tandem mass spectrometry (LC-MS/MS) (e.g., SDS), and can induce additional modifications (e.g., urea). Taken together, all of these irreproducible effects are gradually becoming a problem when label-free quantitation of the samples is envisioned such as during the increasingly popular high-definition mass spectrometry (HDMS(E)) and sequential window acquisition of all theoretical fragment ion spectra (SWATH) data-independent acquisition strategies. Here, we describe the detailed validation of a reproducible method with sufficient protein yield for sample preparation without any known LC-MS/MS interfering substances by using 1% sodium deoxycholate (SDC) during both cell lysis and in-solution digest. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  11. Protocol for Cohesionless Sample Preparation for Physical Experimentation

    Science.gov (United States)

    2016-05-01

    Standard test method for consolidated drained triaxial compression test for soils . In Annual book of ASTM standards. West Conshohocken, PA: ASTM...derived wherein uncertainties and laboratory scatter associated with soil fabric-behavior variance during sample preparation are mitigated. Samples of...wherein comparable analysis between different laboratory tests’ results can be made by ensuring a comparable soil fabric prior to laboratory testing

  12. Modern methods of sample preparation for GC analysis

    NARCIS (Netherlands)

    de Koning, S.; Janssen, H.-G.; Brinkman, U.A.Th.

    2009-01-01

    Today, a wide variety of techniques is available for the preparation of (semi-) solid, liquid and gaseous samples, prior to their instrumental analysis by means of capillary gas chromatography (GC) or, increasingly, comprehensive two-dimensional GC (GC × GC). In the past two decades, a large number

  13. LC-MS analysis of the plasma metabolome–a novel sample preparation strategy

    DEFF Research Database (Denmark)

    Skov, Kasper; Hadrup, Niels; Smedsgaard, Jørn

    2015-01-01

    Blood plasma is a well-known body fluid often analyzed in studies on the effects of toxic compounds as physiological or chemical induced changes in the mammalian body are reflected in the plasma metabolome. Sample preparation prior to LC-MS based analysis of the plasma metabolome is a challenge...... as plasma contains compounds with very different properties. Besides, proteins, which usually are precipitated with organic solvent, phospholipids, are known to cause ion suppression in electrospray mass spectrometry. We have compared two different sample preparation techniques prior to LC-qTOF analysis...... of plasma samples: The first is protein precipitation; the second is protein precipitation followed by solid phase extraction with sub-fractionation into three sub-samples; a phospholipid, a lipid and a polar sub-fraction. Molecular feature extraction of the data files from LC-qTOF analysis of the samples...

  14. Quantitating morphological changes in biological samples during scanning electron microscopy sample preparation with correlative super-resolution microscopy.

    Science.gov (United States)

    Zhang, Ying; Huang, Tao; Jorgens, Danielle M; Nickerson, Andrew; Lin, Li-Jung; Pelz, Joshua; Gray, Joe W; López, Claudia S; Nan, Xiaolin

    2017-01-01

    Sample preparation is critical to biological electron microscopy (EM), and there have been continuous efforts on optimizing the procedures to best preserve structures of interest in the sample. However, a quantitative characterization of the morphological changes associated with each step in EM sample preparation is currently lacking. Using correlative EM and superresolution microscopy (SRM), we have examined the effects of different drying methods as well as osmium tetroxide (OsO4) post-fixation on cell morphology during scanning electron microscopy (SEM) sample preparation. Here, SRM images of the sample acquired under hydrated conditions were used as a baseline for evaluating morphological changes as the sample went through SEM sample processing. We found that both chemical drying and critical point drying lead to a mild cellular boundary retraction of ~60 nm. Post-fixation by OsO4 causes at least 40 nm additional boundary retraction. We also found that coating coverslips with adhesion molecules such as fibronectin prior to cell plating helps reduce cell distortion from OsO4 post-fixation. These quantitative measurements offer useful information for identifying causes of cell distortions in SEM sample preparation and improving current procedures.

  15. EFFECT OF ADDING THE INTERNAL STANDARD TO BLOOD SAMPLES, PRIOR TO THE PREPARATION OF BLOOD SPOTS FOR ACYLCARNITINE ANALYSIS

    OpenAIRE

    Osorio, José Henry; Pourfarzam, Morteza

    2010-01-01

    Background: some general factors can influence when determining acylcarnitines through tandem mass spectrometry. Objective: to study the effect of adding the internal standard to blood samples before the preparation of filter paper cards compared with the addition of internal standard after having the filter paper cards prepared for determining acylcarnitines in blood for tandem mass spectrometry. Methodology: two groups of blood samples were prepared: group one without adding internal standa...

  16. Sample preparation optimization in fecal metabolic profiling.

    Science.gov (United States)

    Deda, Olga; Chatziioannou, Anastasia Chrysovalantou; Fasoula, Stella; Palachanis, Dimitris; Raikos, Νicolaos; Theodoridis, Georgios A; Gika, Helen G

    2017-03-15

    Metabolomic analysis of feces can provide useful insight on the metabolic status, the health/disease state of the human/animal and the symbiosis with the gut microbiome. As a result, recently there is increased interest on the application of holistic analysis of feces for biomarker discovery. For metabolomics applications, the sample preparation process used prior to the analysis of fecal samples is of high importance, as it greatly affects the obtained metabolic profile, especially since feces, as matrix are diversifying in their physicochemical characteristics and molecular content. However there is still little information in the literature and lack of a universal approach on sample treatment for fecal metabolic profiling. The scope of the present work was to study the conditions for sample preparation of rat feces with the ultimate goal of the acquisition of comprehensive metabolic profiles either untargeted by NMR spectroscopy and GC-MS or targeted by HILIC-MS/MS. A fecal sample pooled from male and female Wistar rats was extracted under various conditions by modifying the pH value, the nature of the organic solvent and the sample weight to solvent volume ratio. It was found that the 1/2 (w f /v s ) ratio provided the highest number of metabolites under neutral and basic conditions in both untargeted profiling techniques. Concerning LC-MS profiles, neutral acetonitrile and propanol provided higher signals and wide metabolite coverage, though extraction efficiency is metabolite dependent. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Field Sample Preparation Method Development for Isotope Ratio Mass Spectrometry

    International Nuclear Information System (INIS)

    Leibman, C.; Weisbrod, K.; Yoshida, T.

    2015-01-01

    Non-proliferation and International Security (NA-241) established a working group of researchers from Los Alamos National Laboratory (LANL), Pacific Northwest National Laboratory (PNNL) and Savannah River National Laboratory (SRNL) to evaluate the utilization of in-field mass spectrometry for safeguards applications. The survey of commercial off-the-shelf (COTS) mass spectrometers (MS) revealed no instrumentation existed capable of meeting all the potential safeguards requirements for performance, portability, and ease of use. Additionally, fieldable instruments are unlikely to meet the International Target Values (ITVs) for accuracy and precision for isotope ratio measurements achieved with laboratory methods. The major gaps identified for in-field actinide isotope ratio analysis were in the areas of: 1. sample preparation and/or sample introduction, 2. size reduction of mass analyzers and ionization sources, 3. system automation, and 4. decreased system cost. Development work in 2 through 4, numerated above continues, in the private and public sector. LANL is focusing on developing sample preparation/sample introduction methods for use with the different sample types anticipated for safeguard applications. Addressing sample handling and sample preparation methods for MS analysis will enable use of new MS instrumentation as it becomes commercially available. As one example, we have developed a rapid, sample preparation method for dissolution of uranium and plutonium oxides using ammonium bifluoride (ABF). ABF is a significantly safer and faster alternative to digestion with boiling combinations of highly concentrated mineral acids. Actinides digested with ABF yield fluorides, which can then be analyzed directly or chemically converted and separated using established column chromatography techniques as needed prior to isotope analysis. The reagent volumes and the sample processing steps associated with ABF sample digestion lend themselves to automation and field

  18. Reference Priors For Non-Normal Two-Sample Problems

    NARCIS (Netherlands)

    Fernández, C.; Steel, M.F.J.

    1997-01-01

    The reference prior algorithm (Berger and Bernardo, 1992) is applied to locationscale models with any regular sampling density. A number of two-sample problems is analyzed in this general context, extending the dierence, ratio and product of Normal means problems outside Normality, while explicitly

  19. 40 CFR 761.323 - Sample preparation.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Sample preparation. 761.323 Section... Remediation Waste Samples § 761.323 Sample preparation. (a) The comparison study requires analysis of a... concentrations by dilution. Any excess material resulting from the preparation of these samples, which is not...

  20. Electrodeposition as an alternate method for preparation of environmental samples for iodide by AMS

    Energy Technology Data Exchange (ETDEWEB)

    Adamic, M.L., E-mail: Mary.Adamic@inl.gov [Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83402 (United States); Lister, T.E.; Dufek, E.J.; Jenson, D.D.; Olson, J.E. [Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83402 (United States); Vockenhuber, C. [Laboratory of Ion Beam Physics, ETH Zurich, Otto-Stern-Weg 5, 8093 Zurich (Switzerland); Watrous, M.G. [Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83402 (United States)

    2015-10-15

    This paper presents an evaluation of an alternate method for preparing environmental samples for {sup 129}I analysis by accelerator mass spectrometry (AMS) at Idaho National Laboratory. The optimal sample preparation method is characterized by ease of preparation, capability of processing very small quantities of iodide, and ease of loading into a cathode. Electrodeposition of iodide on a silver wire was evaluated using these criteria. This study indicates that the electrochemically-formed silver iodide deposits produce ion currents similar to those from precipitated silver iodide for the same sample mass. Precipitated silver iodide samples are usually mixed with niobium or silver powder prior to loading in a cathode. Using electrodeposition, the silver is already mixed with the sample and can simply be picked up with tweezers, placed in the sample die, and pressed into a cathode. The major advantage of this method is that the silver wire/electrodeposited silver iodide is much easier to load into a cathode.

  1. Electrodeposition as an alternate method for preparation of environmental samples for iodide by AMS

    International Nuclear Information System (INIS)

    Adamic, M.L.; Lister, T.E.; Dufek, E.J.; Jenson, D.D.; Olson, J.E.; Vockenhuber, C.; Watrous, M.G.

    2015-01-01

    This paper presents an evaluation of an alternate method for preparing environmental samples for "1"2"9I analysis by accelerator mass spectrometry (AMS) at Idaho National Laboratory. The optimal sample preparation method is characterized by ease of preparation, capability of processing very small quantities of iodide, and ease of loading into a cathode. Electrodeposition of iodide on a silver wire was evaluated using these criteria. This study indicates that the electrochemically-formed silver iodide deposits produce ion currents similar to those from precipitated silver iodide for the same sample mass. Precipitated silver iodide samples are usually mixed with niobium or silver powder prior to loading in a cathode. Using electrodeposition, the silver is already mixed with the sample and can simply be picked up with tweezers, placed in the sample die, and pressed into a cathode. The major advantage of this method is that the silver wire/electrodeposited silver iodide is much easier to load into a cathode.

  2. Review of sample preparation techniques for the analysis of pesticide residues in soil.

    Science.gov (United States)

    Tadeo, José L; Pérez, Rosa Ana; Albero, Beatriz; García-Valcárcel, Ana I; Sánchez-Brunete, Consuelo

    2012-01-01

    This paper reviews the sample preparation techniques used for the analysis of pesticides in soil. The present status and recent advances made during the last 5 years in these methods are discussed. The analysis of pesticide residues in soil requires the extraction of analytes from this matrix, followed by a cleanup procedure, when necessary, prior to their instrumental determination. The optimization of sample preparation is a very important part of the method development that can reduce the analysis time, the amount of solvent, and the size of samples. This review considers all aspects of sample preparation, including extraction and cleanup. Classical extraction techniques, such as shaking, Soxhlet, and ultrasonic-assisted extraction, and modern techniques like pressurized liquid extraction, microwave-assisted extraction, solid-phase microextraction and QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) are reviewed. The different cleanup strategies applied for the purification of soil extracts are also discussed. In addition, the application of these techniques to environmental studies is considered.

  3. Sample preparation in foodomic analyses.

    Science.gov (United States)

    Martinović, Tamara; Šrajer Gajdošik, Martina; Josić, Djuro

    2018-04-16

    Representative sampling and adequate sample preparation are key factors for successful performance of further steps in foodomic analyses, as well as for correct data interpretation. Incorrect sampling and improper sample preparation can be sources of severe bias in foodomic analyses. It is well known that both wrong sampling and sample treatment cannot be corrected anymore. These, in the past frequently neglected facts, are now taken into consideration, and the progress in sampling and sample preparation in foodomics is reviewed here. We report the use of highly sophisticated instruments for both high-performance and high-throughput analyses, as well as miniaturization and the use of laboratory robotics in metabolomics, proteomics, peptidomics and genomics. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  4. Generalized species sampling priors with latent Beta reinforcements

    Science.gov (United States)

    Airoldi, Edoardo M.; Costa, Thiago; Bassetti, Federico; Leisen, Fabrizio; Guindani, Michele

    2014-01-01

    Many popular Bayesian nonparametric priors can be characterized in terms of exchangeable species sampling sequences. However, in some applications, exchangeability may not be appropriate. We introduce a novel and probabilistically coherent family of non-exchangeable species sampling sequences characterized by a tractable predictive probability function with weights driven by a sequence of independent Beta random variables. We compare their theoretical clustering properties with those of the Dirichlet Process and the two parameters Poisson-Dirichlet process. The proposed construction provides a complete characterization of the joint process, differently from existing work. We then propose the use of such process as prior distribution in a hierarchical Bayes modeling framework, and we describe a Markov Chain Monte Carlo sampler for posterior inference. We evaluate the performance of the prior and the robustness of the resulting inference in a simulation study, providing a comparison with popular Dirichlet Processes mixtures and Hidden Markov Models. Finally, we develop an application to the detection of chromosomal aberrations in breast cancer by leveraging array CGH data. PMID:25870462

  5. Sample preparation for the HAW project and experimental results from the HFR

    International Nuclear Information System (INIS)

    Garcia Celma, A.; Wees, H. van; Miralles, L.

    1990-09-01

    This report deals with the preparation and analysis of samples, during the period May 1989-November 1989, for the High-Active Waste (HAW) project, a large-scale in situ test being performed underground in the Asse salt mine, Remlingen FRG. The development of the technical procedures required, and the scientific results, which regard mostly characterization of Potasas del Llobregat sample, are reported. Prior to using the samples in both the H.A.W. and the H.F.R. experiments they have to be machined to fit their holders. Technical improvements for machining samples of salt are reported. (H.W.). 9 refs.; 68 figs.; 10 tabs

  6. [Sample preparation methods for chromatographic analysis of organic components in atmospheric particulate matter].

    Science.gov (United States)

    Hao, Liang; Wu, Dapeng; Guan, Yafeng

    2014-09-01

    The determination of organic composition in atmospheric particulate matter (PM) is of great importance in understanding how PM affects human health, environment, climate, and ecosystem. Organic components are also the scientific basis for emission source tracking, PM regulation and risk management. Therefore, the molecular characterization of the organic fraction of PM has become one of the priority research issues in the field of environmental analysis. Due to the extreme complexity of PM samples, chromatographic methods have been the chief selection. The common procedure for the analysis of organic components in PM includes several steps: sample collection on the fiber filters, sample preparation (transform the sample into a form suitable for chromatographic analysis), analysis by chromatographic methods. Among these steps, the sample preparation methods will largely determine the throughput and the data quality. Solvent extraction methods followed by sample pretreatment (e. g. pre-separation, derivatization, pre-concentration) have long been used for PM sample analysis, and thermal desorption methods have also mainly focused on the non-polar organic component analysis in PM. In this paper, the sample preparation methods prior to chromatographic analysis of organic components in PM are reviewed comprehensively, and the corresponding merits and limitations of each method are also briefly discussed.

  7. Inverse problems with non-trivial priors: efficient solution through sequential Gibbs sampling

    DEFF Research Database (Denmark)

    Hansen, Thomas Mejer; Cordua, Knud Skou; Mosegaard, Klaus

    2012-01-01

    Markov chain Monte Carlo methods such as the Gibbs sampler and the Metropolis algorithm can be used to sample solutions to non-linear inverse problems. In principle, these methods allow incorporation of prior information of arbitrary complexity. If an analytical closed form description of the prior...... is available, which is the case when the prior can be described by a multidimensional Gaussian distribution, such prior information can easily be considered. In reality, prior information is often more complex than can be described by the Gaussian model, and no closed form expression of the prior can be given....... We propose an algorithm, called sequential Gibbs sampling, allowing the Metropolis algorithm to efficiently incorporate complex priors into the solution of an inverse problem, also for the case where no closed form description of the prior exists. First, we lay out the theoretical background...

  8. Synchrotron/crystal sample preparation

    Science.gov (United States)

    Johnson, R. Barry

    1993-01-01

    The Center for Applied Optics (CAO) of the University of Alabama in Huntsville (UAH) prepared this final report entitled 'Synchrotron/Crystal Sample Preparation' in completion of contract NAS8-38609, Delivery Order No. 53. Hughes Danbury Optical Systems (HDOS) is manufacturing the Advanced X-ray Astrophysics Facility (AXAF) mirrors. These thin-walled, grazing incidence, Wolter Type-1 mirrors, varying in diameter from 1.2 to 0.68 meters, must be ground and polished using state-of-the-art techniques in order to prevent undue stress due to damage or the presence of crystals and inclusions. The effect of crystals on the polishing and grinding process must also be understood. This involves coating special samples of Zerodur and measuring the reflectivity of the coatings in a synchrotron system. In order to gain the understanding needed on the effect of the Zerodur crystals by the grinding and polishing process, UAH prepared glass samples by cutting, grinding, etching, and polishing as required to meet specifications for witness bars for synchrotron measurements and for investigations of crystals embedded in Zerodur. UAH then characterized these samples for subsurface damage and surface roughness and figure.

  9. Standard methods for sampling and sample preparation for gamma spectroscopy

    International Nuclear Information System (INIS)

    Taskaeva, M.; Taskaev, E.; Nikolov, P.

    1993-01-01

    The strategy for sampling and sample preparation is outlined: necessary number of samples; analysis and treatment of the results received; quantity of the analysed material according to the radionuclide concentrations and analytical methods; the minimal quantity and kind of the data needed for making final conclusions and decisions on the base of the results received. This strategy was tested in gamma spectroscopic analysis of radionuclide contamination of the region of Eleshnitsa Uranium Mines. The water samples was taken and stored according to the ASTM D 3370-82. The general sampling procedures were in conformity with the recommendations of ISO 5667. The radionuclides was concentrated by coprecipitation with iron hydroxide and ion exchange. The sampling of soil samples complied with the rules of ASTM C 998, and their sample preparation - with ASTM C 999. After preparation the samples were sealed hermetically and measured. (author)

  10. [Sample preparation and bioanalysis in mass spectrometry].

    Science.gov (United States)

    Bourgogne, Emmanuel; Wagner, Michel

    2015-01-01

    The quantitative analysis of compounds of clinical interest of low molecular weight (sample preparation. Sample preparation is a crucial part of chemical/biological analysis and in a sense is considered the bottleneck of the whole analytical process. The main objectives of sample preparation are the removal of potential interferences, analyte preconcentration, and converting (if needed) the analyte into a more suitable form for detection or separation. Without chromatographic separation, endogenous compounds, co-eluted products may affect a quantitative method in mass spectrometry performance. This work focuses on three distinct parts. First, quantitative bioanalysis will be defined, different matrices and sample preparation techniques currently used in bioanalysis by mass spectrometry of/for small molecules of clinical interest in biological fluids. In a second step the goals of sample preparation will be described. Finally, in a third step, sample preparation strategies will be made either directly ("dilute and shoot") or after precipitation.

  11. METALLOGRAPHIC SAMPLE PREPARATION STATION-CONSTRUCTIVE CONCEPT

    Directory of Open Access Journals (Sweden)

    AVRAM Florin Timotei

    2016-11-01

    Full Text Available In this paper we propose to present the issues involved in the case of the constructive conception of a station for metallographic sample preparation. This station is destined for laboratory work. The metallographic station is composed of a robot ABB IRB1600, a metallographic microscope, a gripping device, a manipulator, a laboratory grinding and polishing machine. The robot will be used for manipulation of the sample preparation and the manipulator take the sample preparation for processing.

  12. Use of a holder-vacuum tube device to save on-site hands in preparing urine samples for head-space gas-chromatography, and its application to determine the time allowance for sample sealing.

    Science.gov (United States)

    Kawai, Toshio; Sumino, Kimiaki; Ohashi, Fumiko; Ikeda, Masayuki

    2011-01-01

    To facilitate urine sample preparation prior to head-space gas-chromatographic (HS-GC) analysis. Urine samples containing one of the five solvents (acetone, methanol, methyl ethyl ketone, methyl isobutyl ketone and toluene) at the levels of biological exposure limits were aspirated into a vacuum tube via holder, a device commercially available for venous blood collection (the vacuum tube method). The urine sample, 5 ml, was quantitatively transferred to a 20-ml head-space vial prior to HS-GC analysis. The loaded tubes were stored at +4 ℃ in dark for up to 3 d. The vacuum tube method facilitated on-site procedures of urine sample preparation for HS-GC with no significant loss of solvents in the sample and no need of skilled hands, whereas on-site sample preparation time was significantly reduced. Furthermore, no loss of solvents was detected during the 3-d storage, irrespective of hydrophilic (acetone) or lipophilic solvent (toluene). In a pilot application, high performance of the vacuum tube method in sealing a sample in an air-tight space succeeded to confirm that no solvent will be lost when sealing is completed within 5 min after urine voiding, and that the allowance time is as long as 30 min in case of toluene in urine. The use of the holder-vacuum tube device not only saves hands for transfer of the sample to air-tight space, but facilitates sample storage prior to HS-GC analysis.

  13. Monolith Chromatography as Sample Preparation Step in Virome Studies of Water Samples.

    Science.gov (United States)

    Gutiérrez-Aguirre, Ion; Kutnjak, Denis; Rački, Nejc; Rupar, Matevž; Ravnikar, Maja

    2018-01-01

    Viruses exist in aquatic media and many of them use this media as transmission route. Next-generation sequencing (NGS) technologies have opened new doors in virus research, allowing also to reveal a hidden diversity of viral species in aquatic environments. Not surprisingly, many of the newly discovered viruses are found in environmental fresh and marine waters. One of the problems in virome research can be the low amount of viral nucleic acids present in the sample in contrast to the background ones (host, eukaryotic, prokaryotic, environmental). Therefore, virus enrichment prior to NGS is necessary in many cases. In water samples, an added problem resides in the low concentration of viruses typically present in aquatic media. Different concentration strategies have been used to overcome such limitations. CIM monoliths are a new generation of chromatographic supports that due to their particular structural characteristics are very efficient in concentration and purification of viruses. In this chapter, we describe the use of CIM monolithic chromatography for sample preparation step in NGS studies targeting viruses in fresh or marine water. The step-by-step protocol will include a case study where CIM concentration was used to study the virome of a wastewater sample using NGS.

  14. Sample preparation guidelines for two-dimensional electrophoresis.

    Science.gov (United States)

    Posch, Anton

    2014-12-01

    Sample preparation is one of the key technologies for successful two-dimensional electrophoresis (2DE). Due to the great diversity of protein sample types and sources, no single sample preparation method works with all proteins; for any sample the optimum procedure must be determined empirically. This review is meant to provide a broad overview of the most important principles in sample preparation in order to avoid a multitude of possible pitfalls. Sample preparation protocols from the expert in the field were screened and evaluated. On the basis of these protocols and my own comprehensive practical experience important guidelines are given in this review. The presented guidelines will facilitate straightforward protocol development for researchers new to gel-based proteomics. In addition the available choices are rationalized in order to successfully prepare a protein sample for 2DE separations. The strategies described here are not limited to 2DE and can also be applied to other protein separation techniques.

  15. Quantitative in-situ TEM nanotensile testing of single crystal Ni facilitated by a new sample preparation approach.

    Science.gov (United States)

    Samaeeaghmiyoni, Vahid; Idrissi, Hosni; Groten, Jonas; Schwaiger, Ruth; Schryvers, Dominique

    2017-03-01

    Twin-jet electro-polishing and Focused Ion Beam (FIB) were combined to produce small size Nickel single crystal specimens for quantitative in-situ nanotensile experiments in the transmission electron microscope. The combination of these techniques allows producing samples with nearly defect-free zones in the centre in contrast to conventional FIB-prepared samples. Since TEM investigations can be performed on the electro-polished samples prior to in-situ TEM straining, specimens with desired crystallographic orientation and initial microstructure can be prepared. The present results reveal a dislocation nucleation-controlled plasticity, in which small loops induced by FIB near the edges of the samples play a central role. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Collection and preparation of samples for gamma spectrometry

    International Nuclear Information System (INIS)

    Pan Jingquan

    1994-01-01

    The paper presents the basic principles of sample collection and preparation: setting up unified sampling program, methods and procedures, sample packing, transportation and storage, determination of sample quantity, sample pretreatment and preparation of samples to be analysed, etc. for gamma spectrometry. And the paper also describes briefly the main methods and special issues of sampling and preparation for the same environmental and biological samples, such as, air, water, grass, soil and foods

  17. Microfluidic Sample Preparation for Diagnostic Cytopathology

    Science.gov (United States)

    Mach, Albert J.; Adeyiga, Oladunni B.; Di Carlo, Dino

    2014-01-01

    The cellular components of body fluids are routinely analyzed to identify disease and treatment approaches. While significant focus has been placed on developing cell analysis technologies, tools to automate the preparation of cellular specimens have been more limited, especially for body fluids beyond blood. Preparation steps include separating, concentrating, and exposing cells to reagents. Sample preparation continues to be routinely performed off-chip by technicians, preventing cell-based point-of-care diagnostics, increasing the cost of tests, and reducing the consistency of the final analysis following multiple manually-performed steps. Here, we review the assortment of biofluids for which suspended cells are analyzed, along with their characteristics and diagnostic value. We present an overview of the conventional sample preparation processes for cytological diagnosis. We finally discuss the challenges and opportunities in developing microfluidic devices for the purpose of automating or miniaturizing these processes, with particular emphases on preparing large or small volume samples, working with samples of high cellularity, automating multi-step processes, and obtaining high purity subpopulations of cells. We hope to convey the importance of and help identify new research directions addressing the vast biological and clinical applications in preparing and analyzing the array of available biological fluids. Successfully addressing the challenges described in this review can lead to inexpensive systems to improve diagnostic accuracy while simultaneously reducing overall systemic healthcare costs. PMID:23380972

  18. Innovative methods for inorganic sample preparation

    Energy Technology Data Exchange (ETDEWEB)

    Essling, A.M.; Huff, E.A.; Graczyk, D.G.

    1992-04-01

    Procedures and guidelines are given for the dissolution of a variety of selected materials using fusion, microwave, and Parr bomb techniques. These materials include germanium glass, corium-concrete mixtures, and zeolites. Emphasis is placed on sample-preparation approaches that produce a single master solution suitable for complete multielement characterization of the sample. In addition, data are presented on the soil microwave digestion method approved by the Environmental Protection Agency (EPA). Advantages and disadvantages of each sample-preparation technique are summarized.

  19. Innovative methods for inorganic sample preparation

    International Nuclear Information System (INIS)

    Essling, A.M.; Huff, E.A.; Graczyk, D.G.

    1992-04-01

    Procedures and guidelines are given for the dissolution of a variety of selected materials using fusion, microwave, and Parr bomb techniques. These materials include germanium glass, corium-concrete mixtures, and zeolites. Emphasis is placed on sample-preparation approaches that produce a single master solution suitable for complete multielement characterization of the sample. In addition, data are presented on the soil microwave digestion method approved by the Environmental Protection Agency (EPA). Advantages and disadvantages of each sample-preparation technique are summarized

  20. Applications of Blue Light-curing Acrylic Resin to Forensic Sample Preparation and Microtomy.

    Science.gov (United States)

    Groves, Ethan; Palenik, Christopher S

    2016-03-01

    This study discusses the results of an evaluation of a one-part blue light-curing acrylic resin for embedding trace evidence prior to the preparation of thin sections with a microtome. Through a comparison to several epoxy resins, the physical properties relevant to both trace evidence examination and analytical microscopy in general, including as viscosity, clarity, color, hardness, and cure speed, were explored. Finally, thin sections from paint samples embedded in this acrylic resin were evaluated to determine if, through smearing or impregnation, the resin contributed to the infrared spectra. The results of this study show that blue light-curing acrylic resins provide the desired properties of an embedding medium, generate high-quality thin sections, and can significantly simplify the preparation of paint chips, fibers and a multitude of other types of microscopic samples in the forensic trace evidence laboratory. © 2015 American Academy of Forensic Sciences.

  1. Novel Sample-handling Approach for XRD Analysis with Minimal Sample Preparation

    Science.gov (United States)

    Sarrazin, P.; Chipera, S.; Bish, D.; Blake, D.; Feldman, S.; Vaniman, D.; Bryson, C.

    2004-01-01

    Sample preparation and sample handling are among the most critical operations associated with X-ray diffraction (XRD) analysis. These operations require attention in a laboratory environment, but they become a major constraint in the deployment of XRD instruments for robotic planetary exploration. We are developing a novel sample handling system that dramatically relaxes the constraints on sample preparation by allowing characterization of coarse-grained material that would normally be impossible to analyze with conventional powder-XRD techniques.

  2. Newly introduced sample preparation techniques: towards miniaturization.

    Science.gov (United States)

    Costa, Rosaria

    2014-01-01

    Sampling and sample preparation are of crucial importance in an analytical procedure, representing quite often a source of errors. The technique chosen for the isolation of analytes greatly affects the success of a chemical determination. On the other hand, growing concerns about environmental and human safety, along with the introduction of international regulations for quality control, have moved the interest of scientists towards specific needs. Newly introduced sample preparation techniques are challenged to meet new criteria: (i) miniaturization, (ii) higher sensitivity and selectivity, and (iii) automation. In this survey, the most recent techniques introduced in the field of sample preparation will be described and discussed, along with many examples of applications.

  3. Sample preparation of environmental samples using benzene synthesis followed by high-performance LSC

    International Nuclear Information System (INIS)

    Filippis, S. De; Noakes, J.E.

    1991-01-01

    Liquid scintillation counting (LSC) techniques have been widely employed as the detection method for determining environmental levels of tritium and 14 C. Since anthropogenic and nonanthropogenic inputs to the environment are a concern, sampling the environment surrounding a nuclear power facility or fuel reprocessing operation requires the collection of many different sample types, including agriculture products, water, biota, aquatic life, soil, and vegetation. These sample types are not suitable for the direct detection of tritium of 14 C for liquid scintillation techniques. Each sample type must be initially prepared in order to obtain the carbon or hydrogen component of interest and present this in a chemical form that is compatible with common chemicals used in scintillation counting applications. Converting the sample of interest to chemically pure benzene as a sample preparation technique has been widely accepted for processing samples for radiocarbon age-dating applications. The synthesized benzene is composed of the carbon or hydrogen atoms from the original sample and is ideal as a solvent for LSC with excellent photo-optical properties. Benzene synthesis followed by low-background scintillation counting can be applied to the preparation and measurement of environmental samples yielding good detection sensitivities, high radionuclide counting efficiency, and shorter preparation time. The method of benzene synthesis provides a unique approach to the preparation of a wide variety of environmental sample types using similar chemistry for all samples

  4. Quantitative sample preparation of some heavy elements

    International Nuclear Information System (INIS)

    Jaffey, A.H.

    1977-01-01

    A discussion is given of some techniques that have been useful in quantitatively preparing and analyzing samples used in the half-life determinations of some plutonium and uranium isotopes. Application of these methods to the preparation of uranium and plutonium samples used in neutron experiments is discussed

  5. 7 CFR 27.21 - Preparation of samples of cotton.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Preparation of samples of cotton. 27.21 Section 27.21... REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.21 Preparation of samples of cotton. The samples from each bale shall be prepared as specified in this section...

  6. Sample preparation in alkaline media

    International Nuclear Information System (INIS)

    Nobrega, Joaquim A.; Santos, Mirian C.; Sousa, Rafael A. de; Cadore, Solange; Barnes, Ramon M.; Tatro, Mark

    2006-01-01

    The use of tetramethylammonium hydroxide, tertiary amines and strongly alkaline reagents for sample treatment involving extraction and digestion procedures is discussed in this review. The preparation of slurries is also discussed. Based on literature data, alkaline media offer a good alternative for sample preparation involving an appreciable group of analytes in different types of samples. These reagents are also successfully employed in tailored speciation procedures wherein there is a critical dependence on maintenance of chemical forms. The effects of these reagents on measurements performed using spectroanalytical techniques are discussed. Several undesirable effects on transport and atomization processes necessitate use of the method of standard additions to obtain accurate results. It is also evident that alkaline media can improve the performance of techniques such as inductively coupled plasma mass spectrometry and accessories, such as autosamplers coupled to graphite furnace atomic absorption spectrometers

  7. Urine sample preparation for proteomic analysis.

    Science.gov (United States)

    Olszowy, Pawel; Buszewski, Boguslaw

    2014-10-01

    Sample preparation for both environmental and more importantly biological matrices is a bottleneck of all kinds of analytical processes. In the case of proteomic analysis this element is even more important due to the amount of cross-reactions that should be taken into consideration. The incorporation of new post-translational modifications, protein hydrolysis, or even its degradation is possible as side effects of proteins sample processing. If protocols are evaluated appropriately, then identification of such proteins does not bring difficulties. However, if structural changes are provided without sufficient attention then protein sequence coverage will be reduced or even identification of such proteins could be impossible. This review summarizes obstacles and achievements in protein sample preparation of urine for proteome analysis using different tools for mass spectrometry analysis. The main aim is to present comprehensively the idea of urine application as a valuable matrix. This article is dedicated to sample preparation and application of urine mainly in novel cancer biomarkers discovery. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Collection and preparation of samples for Agency's programme of intercalibration methods and procedures for measurement of environmental radioactivity

    International Nuclear Information System (INIS)

    Patel, B.

    1975-12-01

    In the period of 1971-1975 several samples of marine sediment and organisms were collected from the Bombay Harbour Bay as well as from the vicinity of the Tarapur nuclear power station in order to supply the materials for preparing intercalibration samples for radionuclides measurements. All samples collected were freeze-dried and homogenized prior to the dispatch to the Monaco Laboratory, where final homogenization and the homogeneity tests were carried out. Altogether 2 marine organisms and 3 marine sediments were supplied during this period. The materials supplied were proved to be useful to prepare intercalibration samples for radionuclide measurements in the levels for monitoring operations. Based on these materials several intercalibration exercises were successfully conducted. This work thus formed a basis for bringing the better comparability of radionuclide measurements in marine environmental samples in an international scale

  9. Recent advances in applications of nanomaterials for sample preparation.

    Science.gov (United States)

    Xu, Linnan; Qi, Xiaoyue; Li, Xianjiang; Bai, Yu; Liu, Huwei

    2016-01-01

    Sample preparation is a key step for qualitative and quantitative analysis of trace analytes in complicated matrix. Along with the rapid development of nanotechnology in material science, numerous nanomaterials have been developed with particularly useful applications in analytical chemistry. Benefitting from their high specific areas, increased surface activities, and unprecedented physical/chemical properties, the potentials of nanomaterials for rapid and efficient sample preparation have been exploited extensively. In this review, recent progress of novel nanomaterials applied in sample preparation has been summarized and discussed. Both nanoparticles and nanoporous materials are evaluated for their unusual performance in sample preparation. Various compositions and functionalizations extended the applications of nanomaterials in sample preparations, and distinct size and shape selectivity was generated from the diversified pore structures of nanoporous materials. Such great variety make nanomaterials a kind of versatile tools in sample preparation for almost all categories of analytes. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Influence of feed provisioning prior to digesta sampling on precaecal amino acid digestibility in broiler chickens.

    Science.gov (United States)

    Siegert, Wolfgang; Ganzer, Christian; Kluth, Holger; Rodehutscord, Markus

    2018-06-01

    A regression approach was applied to determine the influence of feed provisioning prior to digesta sampling on precaecal (pc) amino acid (AA) digestibility in broiler chickens. Soybean meal was used as an example test ingredient. Five feed-provisioning protocols were investigated, four with restricted provision and one with ad libitum provision. When provision was restricted, feed was provided for 30 min after a withdrawal period of 12 h. Digesta were sampled 1, 2, 4 and 6 h after feeding commenced. A diet containing 300 g maize starch/kg was prepared. Half or all the maize starch was replaced with soybean meal in two other diets. Average pc digestibility of all determined AA in the soybean meal was 86% for the 4 and 6-h protocols and 66% and 60% for the 2 and 1-h protocols, respectively. Average pc AA digestibility of soybean meal was 76% for ad libitum feed provision. Feed provisioning also influenced the determined variance. Variance in digestibility ranked in magnitude 1 h > ad libitum > 2 h > 6 h > 4 h for all AA. Owing to the considerable influence of feed-provisioning protocols found in this study, comparisons of pc AA digestibility between studies applying different protocols prior to digesta sampling must be treated with caution. Digestibility experiments aimed at providing estimates for practical feed formulation should use feed-provisioning procedures similar to those used in practice.

  11. Liquid scintillation: Sample preparation and counting atypical emissions

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    Liquid scintillation sample preparation has the most published information but the least amount of definitive technical direction because the chemical and physical nature of the samples from biological investigations varies widely. This chapter discusses the following related topics: Aqueous Samples; Tissue Solubilizers; Absorption of 14 CO 2 ; Sample Combustion Methods; Heterogeneous Systems; Sample Preparation Problems (colored samples, chemiluminescence, photoluminescence, static electricity); Counting Various Types of Emitters; Counting Atypical Emissions. 2 refs., 2 figs

  12. Recent advances in column switching sample preparation in bioanalysis.

    Science.gov (United States)

    Kataoka, Hiroyuki; Saito, Keita

    2012-04-01

    Column switching techniques, using two or more stationary phase columns, are useful for trace enrichment and online automated sample preparation. Target fractions from the first column are transferred online to a second column with different properties for further separation. Column switching techniques can be used to determine the analytes in a complex matrix by direct sample injection or by simple sample treatment. Online column switching sample preparation is usually performed in combination with HPLC or capillary electrophoresis. SPE or turbulent flow chromatography using a cartridge column and in-tube solid-phase microextraction using a capillary column have been developed for convenient column switching sample preparation. Furthermore, various micro-/nano-sample preparation devices using new polymer-coating materials have been developed to improve extraction efficiency. This review describes current developments and future trends in novel column switching sample preparation in bioanalysis, focusing on innovative column switching techniques using new extraction devices and materials.

  13. Advancement of Solidification Processing Technology Through Real Time X-Ray Transmission Microscopy: Sample Preparation

    Science.gov (United States)

    Stefanescu, D. M.; Curreri, P. A.

    1996-01-01

    Two types of samples were prepared for the real time X-ray transmission microscopy (XTM) characterization. In the first series directional solidification experiments were carried out to evaluate the critical velocity of engulfment of zirconia particles in the Al and Al-Ni eutectic matrix under ground (l-g) conditions. The particle distribution in the samples was recorded on video before and after the samples were directionally solidified. In the second series samples of the above two type of composites were prepared for directional solidification runs to be carried out on the Advanced Gradient Heating Facility (AGHF) aboard the space shuttle during the LMS mission in June 1996. X-ray microscopy proved to be an invaluable tool for characterizing the particle distribution in the metal matrix samples. This kind of analysis helped in determining accurately the critical velocity of engulfment of ceramic particles by the melt interface in the opaque metal matrix composites. The quality of the cast samples with respect to porosity and instrumented thermocouple sheath breakage or shift could be easily viewed and thus helped in selecting samples for the space shuttle experiments. Summarizing the merits of this technique it can be stated that this technique enabled the use of cast metal matrix composite samples since the particle location was known prior to the experiment.

  14. The role of sample preparation in interpretation of trace element concentration variability in moss bioindication studies

    Science.gov (United States)

    Migaszewski, Z.M.; Lamothe, P.J.; Crock, J.G.; Galuszka, A.; Dolegowska, S.

    2011-01-01

    Trace element concentrations in plant bioindicators are often determined to assess the quality of the environment. Instrumental methods used for trace element determination require digestion of samples. There are different methods of sample preparation for trace element analysis, and the selection of the best method should be fitted for the purpose of a study. Our hypothesis is that the method of sample preparation is important for interpretation of the results. Here we compare the results of 36 element determinations performed by ICP-MS on ashed and on acid-digested (HNO3, H2O2) samples of two moss species (Hylocomium splendens and Pleurozium schreberi) collected in Alaska and in south-central Poland. We found that dry ashing of the moss samples prior to analysis resulted in considerably lower detection limits of all the elements examined. We also show that this sample preparation technique facilitated the determination of interregional and interspecies differences in the chemistry of trace elements. Compared to the Polish mosses, the Alaskan mosses displayed more positive correlations of the major rock-forming elements with ash content, reflecting those elements' geogenic origin. Of the two moss species, P. schreberi from both Alaska and Poland was also highlighted by a larger number of positive element pair correlations. The cluster analysis suggests that the more uniform element distribution pattern of the Polish mosses primarily reflects regional air pollution sources. Our study has shown that the method of sample preparation is an important factor in statistical interpretation of the results of trace element determinations. ?? 2010 Springer-Verlag.

  15. Modular microfluidic system for biological sample preparation

    Science.gov (United States)

    Rose, Klint A.; Mariella, Jr., Raymond P.; Bailey, Christopher G.; Ness, Kevin Dean

    2015-09-29

    A reconfigurable modular microfluidic system for preparation of a biological sample including a series of reconfigurable modules for automated sample preparation adapted to selectively include a) a microfluidic acoustic focusing filter module, b) a dielectrophoresis bacteria filter module, c) a dielectrophoresis virus filter module, d) an isotachophoresis nucleic acid filter module, e) a lyses module, and f) an isotachophoresis-based nucleic acid filter.

  16. Applications of Liquid-Phase Microextraction in the Sample Preparation of Environmental Solid Samples

    Directory of Open Access Journals (Sweden)

    Helena Prosen

    2014-05-01

    Full Text Available Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc. published in the last decade. Several innovative liquid-phase microextraction (LPME techniques that have emerged recently have also been applied as an aid in sample preparation of these samples: single-drop microextraction (SDME, hollow fiber-liquid phase microextraction (HF-LPME, dispersive liquid-liquid microextraction (DLLME. Besides the common organic solvents, surfactants and ionic liquids are also used. However, these techniques have to be combined with another technique to release the analytes from the solid sample into an aqueous solution. In the present review, the published methods were categorized into three groups: LPME in combination with a conventional solvent extraction; LPME in combination with an environmentally friendly extraction; LPME without previous extraction. The applicability of these approaches to the sample preparation for the determination of pollutants in solid environmental samples is discussed, with emphasis on their strengths, weak points and environmental impact.

  17. Applications of liquid-phase microextraction in the sample preparation of environmental solid samples.

    Science.gov (United States)

    Prosen, Helena

    2014-05-23

    Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc.) published in the last decade. Several innovative liquid-phase microextraction (LPME) techniques that have emerged recently have also been applied as an aid in sample preparation of these samples: single-drop microextraction (SDME), hollow fiber-liquid phase microextraction (HF-LPME), dispersive liquid-liquid microextraction (DLLME). Besides the common organic solvents, surfactants and ionic liquids are also used. However, these techniques have to be combined with another technique to release the analytes from the solid sample into an aqueous solution. In the present review, the published methods were categorized into three groups: LPME in combination with a conventional solvent extraction; LPME in combination with an environmentally friendly extraction; LPME without previous extraction. The applicability of these approaches to the sample preparation for the determination of pollutants in solid environmental samples is discussed, with emphasis on their strengths, weak points and environmental impact.

  18. Indigenous development of automated metallographic sample preparation system

    International Nuclear Information System (INIS)

    Kulkarni, A.P.; Pandit, K.M.; Deshmukh, A.G.; Sahoo, K.C.

    2005-01-01

    Surface preparation of specimens for Metallographic studies on irradiated material involves a lot of remote handling of radioactive material by skilled manpower. These are laborious and man-rem intensive activities and put limitations on number of samples that can be prepared for the metallographic studies. To overcome these limitations, automated systems have been developed for surface preparation of specimens in PIE division. The system includes (i) Grinding and polishing stations (ii) Water jet cleaning station (iii) Ultrasonic cleaning stations (iv) Drying station (v) Sample loading and unloading station (vi) Dispenser for slurries and diluents and (vii) Automated head for movement of the sample holder disc from one station to other. System facilities the operator for programming/changing sequence of the sample preparations including remote changing of grinding/polishing discs from the stations. Two such systems have been installed and commissioned in Hot Cell for PIE Division. These are being used for preparation of irradiated samples from nuclear fuels and structural components. This development has increased the throughput of metallography work and savings in terms of (man-severts) radiation exposure to operators. This presentation will provide details of the challenges in undertaking this developmental work. (author)

  19. Applications of Liquid-Phase Microextraction in the Sample Preparation of Environmental Solid Samples

    OpenAIRE

    Helena Prosen

    2014-01-01

    Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc.) published in the last decade. Several...

  20. New materials for sample preparation techniques in bioanalysis.

    Science.gov (United States)

    Nazario, Carlos Eduardo Domingues; Fumes, Bruno Henrique; da Silva, Meire Ribeiro; Lanças, Fernando Mauro

    2017-02-01

    The analysis of biological samples is a complex and difficult task owing to two basic and complementary issues: the high complexity of most biological matrices and the need to determine minute quantities of active substances and contaminants in such complex sample. To succeed in this endeavor samples are usually subject to three steps of a comprehensive analytical methodological approach: sample preparation, analytes isolation (usually utilizing a chromatographic technique) and qualitative/quantitative analysis (usually with the aid of mass spectrometric tools). Owing to the complex nature of bio-samples, and the very low concentration of the target analytes to be determined, selective sample preparation techniques is mandatory in order to overcome the difficulties imposed by these two constraints. During the last decade new chemical synthesis approaches has been developed and optimized, such as sol-gel and molecularly imprinting technologies, allowing the preparation of novel materials for sample preparation including graphene and derivatives, magnetic materials, ionic liquids, molecularly imprinted polymers, and much more. In this contribution we will review these novel techniques and materials, as well as their application to the bioanalysis niche. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Evaluation of six sample preparation procedures for qualitative and quantitative proteomics analysis of milk fat globule membrane.

    Science.gov (United States)

    Yang, Yongxin; Anderson, Elizabeth; Zhang, Sheng

    2018-04-12

    Proteomic analysis of membrane proteins is challenged by the proteins solubility and detergent incompatibility with MS analysis. No single perfect protocol can be used to comprehensively characterize the proteome of membrane fraction. Here, we used cow milk fat globule membrane (MFGM) proteome analysis to assess six sample preparation procedures including one in-gel and five in-solution digestion approaches prior to LC-MS/MS analysis. The largest number of MFGM proteins were identified by suspension trapping (S-Trap) and filter-aided sample preparation (FASP) methods, followed by acetone precipitation without clean-up of tryptic peptides method. Protein identifications with highest average coverage was achieved by Chloroform/MeOH, in-gel and S-Trap methods. Most distinct proteins were identified by FASP method, followed by S-Trap. Analyses by Venn diagram, principal-component analysis, hierarchical clustering and the abundance ranking of quantitative proteins highlight differences in the MFGM fraction by the all sample preparation procedures. These results reveal the biased proteins/peptides loss occurred in each protocol. In this study, we found several novel proteins that were not observed previously by in-depth proteomics characterization of MFGM fraction in milk. Thus, a combination of multiple procedures with orthologous properties of sample preparation was demonstrated to improve the protein sequence coverage and expression level accuracy of membrane samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Sample Preparation for Electron Probe Microanalysis-Pushing the Limits.

    Science.gov (United States)

    Geller, Joseph D; Engle, Paul D

    2002-01-01

    There are two fundamental considerations in preparing samples for electron probe microanalysis (EPMA). The first one may seem obvious, but we often find it is overlooked. That is, the sample analyzed should be representative of the population from which it comes. The second is a direct result of the assumptions in the calculations used to convert x-ray intensity ratios, between the sample and standard, to concentrations. Samples originate from a wide range of sources. During their journey to being excited under the electron beam for the production of x rays there are many possibilities for sample alteration. Handling can contaminate samples by adding extraneous matter. In preparation, the various abrasives used in sizing the sample by sawing, grinding and polishing can embed themselves. The most accurate composition of a contaminated sample is, at best, not representative of the original sample; it is misleading. Our laboratory performs EPMA analysis on customer submitted samples and prepares over 250 different calibration standards including pure elements, compounds, alloys, glasses and minerals. This large variety of samples does not lend itself to mass production techniques, including automatic polishing. Our manual preparation techniques are designed individually for each sample. The use of automated preparation equipment does not lend itself to this environment, and is not included in this manuscript. The final step in quantitative electron probe microanalysis is the conversion of x-ray intensities ratios, known as the "k-ratios," to composition (in mass fraction or atomic percent) and/or film thickness. Of the many assumptions made in the ZAF (where these letters stand for atomic number, absorption and fluorescence) corrections the localized geometry between the sample and electron beam, or takeoff angle, must be accurately known. Small angular errors can lead to significant errors in the final results. The sample preparation technique then becomes very

  3. Preparation of honey sample for tritium monitoring

    International Nuclear Information System (INIS)

    Chen Bingru; Wang Chenlian; Wang Weihua

    1989-01-01

    The method of preparation of honey sample for tritium monitoring was described. The equipments consist of an air and honey supply system, a quartz combustor with CM-type monolithic combustion catalyst and a condensation system. In the equipments, honey sample was converted into cooling water by the distilling, cracking and carbonizing procedures for tritium counting. The recovery ratio is 99.0 ± 4.5 percent for tritiated water and 96.0 ± 2.0 for tritiated organic compounds. It is a feasible preparing method for the total tritium monitoring in honey sample

  4. An overview of the main foodstuff sample preparation technologies for tetracycline residue determination.

    Science.gov (United States)

    Pérez-Rodríguez, Michael; Pellerano, Roberto Gerardo; Pezza, Leonardo; Pezza, Helena Redigolo

    2018-05-15

    Tetracyclines are widely used for both the treatment and prevention of diseases in animals as well as for the promotion of rapid animal growth and weight gain. This practice may result in trace amounts of these drugs in products of animal origin, such as milk and eggs, posing serious risks to human health. The presence of tetracycline residues in foods can lead to the transmission of antibiotic-resistant pathogenic bacteria through the food chain. In order to ensure food safety and avoid exposure to these substances, national and international regulatory agencies have established tolerance levels for authorized veterinary drugs, including tetracycline antimicrobials. In view of that, numerous sensitive and specific methods have been developed for the quantification of these compounds in different food matrices. One will note, however, that the determination of trace residues in foods such as milk and eggs often requires extensive sample extraction and preparation prior to conducting instrumental analysis. Sample pretreatment is usually the most complicated step in the analytical process and covers both cleaning and pre-concentration. Optimal sample preparation can reduce analysis time and sources of error, enhance sensitivity, apart from enabling unequivocal identification, confirmation and quantification of target analytes. The development and implementation of more environmentally friendly analytical procedures, which involve the use of less hazardous solvents and smaller sample sizes compared to traditional methods, is a rapidly increasing trend in analytical chemistry. This review seeks to provide an updated overview of the main trends in sample preparation for the determination of tetracycline residues in foodstuffs. The applicability of several extraction and clean-up techniques employed in the analysis of foodstuffs, especially milk and egg samples, is also thoroughly discussed. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Platelet-rich fibrin prepared from stored whole-blood samples.

    Science.gov (United States)

    Isobe, Kazushige; Suzuki, Masashi; Watanabe, Taisuke; Kitamura, Yutaka; Suzuki, Taiji; Kawabata, Hideo; Nakamura, Masayuki; Okudera, Toshimitsu; Okudera, Hajime; Uematsu, Kohya; Nakata, Koh; Tanaka, Takaaki; Kawase, Tomoyuki

    2017-12-01

    In regenerative therapy, self-clotted platelet concentrates, such as platelet-rich fibrin (PRF), are generally prepared on-site and are immediately used for treatment. If blood samples or prepared clots can be preserved for several days, their clinical applicability will expand. Here, we prepared PRF from stored whole-blood samples and examined their characteristics. Blood samples were collected from non-smoking, healthy male donors (aged 27-67 years, N = 6), and PRF clots were prepared immediately or after storage for 1-2 days. Fibrin fiber was examined by scanning electron microscopy. Bioactivity was evaluated by means of a bioassay system involving human periosteal cells, whereas PDGF-BB concentrations were determined by an enzyme-linked immunosorbent assay. Addition of optimal amounts of a 10% CaCl 2 solution restored the coagulative ability of whole-blood samples that contained an anticoagulant (acid citrate dextrose) and were stored for up to 2 days at ambient temperature. In PRF clots prepared from the stored whole-blood samples, the thickness and cross-links of fibrin fibers were almost identical to those of freshly prepared PRF clots. PDGF-BB concentrations in the PRF extract were significantly lower in stored whole-blood samples than in fresh samples; however, both extracts had similar stimulatory effects on periosteal-cell proliferation. Quality of PRF clots prepared from stored whole-blood samples is not reduced significantly and can be ensured for use in regenerative therapy. Therefore, the proposed method enables a more flexible treatment schedule and choice of a more suitable platelet concentrate immediately before treatment, not after blood collection.

  6. The effect of sample preparation on uranium hydriding

    International Nuclear Information System (INIS)

    Banos, A.; Stitt, C.A.; Scott, T.B.

    2016-01-01

    Highlights: • Distinct differences in uranium hydride growth rates and characteristics between different surface preparation methods. • The primary difference between the categories of sample preparations is the level of strain present in the surface. • Greater surface-strain, leads to higher nucleation number density, implying a preferred attack of strained vs unstrained metal. • As strain is reduced, surface features such as carbides and grain boundaries become more important in controlling the UH3 location. - Abstract: The influence of sample cleaning preparation on the early stages of uranium hydriding has been examined, by using four identical samples but concurrently prepared using four different methods. The samples were reacted together in the same corrosion cell to ensure identical exposure conditions. From the analysis, it was found that the hydride nucleation rate was proportional to the level of strain exhibiting higher number density for the more strained surfaces. Additionally, microstructure of the metal plays a secondary role regarding initial hydrogen attack on the highly strained surfaces yet starts to dominate the system while moving to more pristine samples.

  7. Efficient sample preparation from complex biological samples using a sliding lid for immobilized droplet extractions.

    Science.gov (United States)

    Casavant, Benjamin P; Guckenberger, David J; Beebe, David J; Berry, Scott M

    2014-07-01

    Sample preparation is a major bottleneck in many biological processes. Paramagnetic particles (PMPs) are a ubiquitous method for isolating analytes of interest from biological samples and are used for their ability to thoroughly sample a solution and be easily collected with a magnet. There are three main methods by which PMPs are used for sample preparation: (1) removal of fluid from the analyte-bound PMPs, (2) removal of analyte-bound PMPs from the solution, and (3) removal of the substrate (with immobilized analyte-bound PMPs). In this paper, we explore the third and least studied method for PMP-based sample preparation using a platform termed Sliding Lid for Immobilized Droplet Extractions (SLIDE). SLIDE leverages principles of surface tension and patterned hydrophobicity to create a simple-to-operate platform for sample isolation (cells, DNA, RNA, protein) and preparation (cell staining) without the need for time-intensive wash steps, use of immiscible fluids, or precise pinning geometries. Compared to other standard isolation protocols using PMPs, SLIDE is able to perform rapid sample preparation with low (0.6%) carryover of contaminants from the original sample. The natural recirculation occurring within the pinned droplets of SLIDE make possible the performance of multistep cell staining protocols within the SLIDE by simply resting the lid over the various sample droplets. SLIDE demonstrates a simple easy to use platform for sample preparation on a range of complex biological samples.

  8. Sample Preparation for Electron Probe Microanalysis—Pushing the Limits

    Science.gov (United States)

    Geller, Joseph D.; Engle, Paul D.

    2002-01-01

    There are two fundamental considerations in preparing samples for electron probe microanalysis (EPMA). The first one may seem obvious, but we often find it is overlooked. That is, the sample analyzed should be representative of the population from which it comes. The second is a direct result of the assumptions in the calculations used to convert x-ray intensity ratios, between the sample and standard, to concentrations. Samples originate from a wide range of sources. During their journey to being excited under the electron beam for the production of x rays there are many possibilities for sample alteration. Handling can contaminate samples by adding extraneous matter. In preparation, the various abrasives used in sizing the sample by sawing, grinding and polishing can embed themselves. The most accurate composition of a contaminated sample is, at best, not representative of the original sample; it is misleading. Our laboratory performs EPMA analysis on customer submitted samples and prepares over 250 different calibration standards including pure elements, compounds, alloys, glasses and minerals. This large variety of samples does not lend itself to mass production techniques, including automatic polishing. Our manual preparation techniques are designed individually for each sample. The use of automated preparation equipment does not lend itself to this environment, and is not included in this manuscript. The final step in quantitative electron probe microanalysis is the conversion of x-ray intensities ratios, known as the “k-ratios,” to composition (in mass fraction or atomic percent) and/or film thickness. Of the many assumptions made in the ZAF (where these letters stand for atomic number, absorption and fluorescence) corrections the localized geometry between the sample and electron beam, or takeoff angle, must be accurately known. Small angular errors can lead to significant errors in the final results. The sample preparation technique then becomes very

  9. 40 CFR 205.160-2 - Test sample selection and preparation.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Test sample selection and preparation... sample selection and preparation. (a) Vehicles comprising the sample which are required to be tested... maintained in any manner unless such preparation, tests, modifications, adjustments or maintenance are part...

  10. FISHprep: A Novel Integrated Device for Metaphase FISH Sample Preparation

    DEFF Research Database (Denmark)

    Shah, Pranjul Jaykumar; Vedarethinam, Indumathi; Kwasny, Dorota

    2011-01-01

    We present a novel integrated device for preparing metaphase chromosomes spread slides (FISHprep). The quality of cytogenetic analysis from patient samples greatly relies on the efficiency of sample pre-treatment and/or slide preparation. In cytogenetic slide preparation, cell cultures...... are routinely used to process samples (for culture, arrest and fixation of cells) and/or to expand limited amount of samples (in case of prenatal diagnostics). Arguably, this expansion and other sample pretreatments form the longest part of the entire diagnostic protocols spanning over 3–4 days. We present here...... with minimal handling for metaphase FISH slide preparation....

  11. Independent assessment of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) sample preparation quality: Effect of sample preparation on MALDI-MS of synthetic polymers.

    Science.gov (United States)

    Kooijman, Pieter C; Kok, Sander; Honing, Maarten

    2017-02-28

    Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) provides detailed and in-depth information about the molecular characteristics of synthetic polymers. To obtain the most accurate results the sample preparation parameters should be chosen to suit the sample and the aim of the experiment. Because the underlying principles of MALDI are still not fully known, a priori determination of optimal sample preparation protocols is often not possible. Employing an automated sample preparation quality assessment method recently presented by us we quantified the sample preparation quality obtained using various sample preparation protocols. Six conventional matrices with and without added potassium as a cationization agent and six ionic liquid matrices (ILMs) were assessed using poly(ethylene glycol) (PEG), polytetrahydrofuran (PTHF) and poly(methyl methacrylate) (PMMA) as samples. All sample preparation protocols were scored and ranked based on predefined quality parameters and spot-to-spot repeatability. Clearly distinctive preferences were observed in matrix identity and cationization agent for PEG, PTHF and PMMA, as the addition of an excess of potassium cationization agent results in an increased score for PMMA and a contrasting matrix-dependent effect for PTHF and PEG. The addition of excess cationization agent to sample mixtures dissipates any overrepresentation of high molecular weight polymer species. Our results show reduced ionization efficiency and similar sample deposit homogeneity for all tested ILMs, compared with well-performing conventional MALDI matrices. The results published here represent a start in the unsupervised quantification of sample preparation quality for MALDI samples. This method can select the best sample preparation parameters for any synthetic polymer sample and the results can be used to formulate hypotheses on MALDI principles. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Alteration in sample preparation to increase the yield of multiplex Polymerase Chain Reaction assay for diagnosis of genital ulcer disease

    Directory of Open Access Journals (Sweden)

    G Rao

    2013-01-01

    Full Text Available Purpose: Genital Ulcer Disease (GUD is common sexually transmitted infection (STI. Multiple studies have shown that GUDs are strongly associated with the transmission and the acquisition of HIV infection. An accurate diagnosis of common etiology of GUD namely Herpes, syphilis and Chancroid is possible using Multiplex PCR (M-PCR. However, frequent presence of Polymerase Chain Reaction inhibitors in the ulcer swab specimen limits the performance of the assay. In order to overcome this problem, alternative specimen preparation method was used. Materials and Methods: To determine the common etiology, GUD specimens obtained under an STI operations research study were tested with M-PCR after the samples were prepared using Roche Amplicor specimen preparation kit. PCR inhibiting samples were identified from that, which showed negative results. These samples were subjected to phenol-chloroform extraction and ethanol precipitation before the conduct of M-PCR on them. Results: Of the 237 GUD specimens tested, in 145 etiologies could be detected, whereas 92 samples were found negative. Further spiking with one of the target DNA, 128 of the negative samples were found to contain the inhibitors. These 126 samples were then subjected to phenol chloroform extraction and ethanol precipitation followed by M-PCR. Using this method for sample preparation, etiology could be determined in 46 (23% additional samples. This success rate of altered sample preparation method has been lower than that has reported. Conclusion: The results indicate that sample preparation using phenol chloroform extraction and ethanol precipitation, prior to M-PCR helps to eliminate the inhibitors and increase the yield of the assay. However, being a laborious procedure, it may be used for samples giving negative results after the screening by Roche Amplicor specimen preparation kit.

  13. Congener Production in Blood Samples During Preparation and Storage

    DEFF Research Database (Denmark)

    Felby, Søren; Nielsen, Erik

    1995-01-01

    Retsmedicin, congener production, preparation, head space GC, acetone, isobutanol, storage, blood samples, n-propanol, methanol, methylethylketone......Retsmedicin, congener production, preparation, head space GC, acetone, isobutanol, storage, blood samples, n-propanol, methanol, methylethylketone...

  14. Trends in sample preparation 2002. Development and application. Book of abstracts

    International Nuclear Information System (INIS)

    Wenzl, T.; Eberl, M.; Zischka, M.; Knapp, G.

    2002-01-01

    This conference comprised topics dealing with sample preparation such as: sample decomposition, solvent extraction, derivatization techniques and uncertainty in sample preparation. In particular microwave assisted sample preparation techniques and equipment were discussed. The papers were organized under the general topics: trace element analysis, trace analysis of organic compounds, high performance instrumentation in sample preparation, speciation analysis and posters session. Those papers of INIS interest are cited individually. (nevyjel)

  15. Trends in sample preparation 2002. Development and application. Book of abstracts

    Energy Technology Data Exchange (ETDEWEB)

    Wenzl, T; Eberl, M; Zischka, M; Knapp, G [eds.

    2002-07-01

    This conference comprised topics dealing with sample preparation such as: sample decomposition, solvent extraction, derivatization techniques and uncertainty in sample preparation. In particular microwave assisted sample preparation techniques and equipment were discussed. The papers were organized under the general topics: trace element analysis, trace analysis of organic compounds, high performance instrumentation in sample preparation, speciation analysis and posters session. Those papers of INIS interest are cited individually. (nevyjel)

  16. Rapid sampling of molecular motions with prior information constraints.

    Science.gov (United States)

    Raveh, Barak; Enosh, Angela; Schueler-Furman, Ora; Halperin, Dan

    2009-02-01

    Proteins are active, flexible machines that perform a range of different functions. Innovative experimental approaches may now provide limited partial information about conformational changes along motion pathways of proteins. There is therefore a need for computational approaches that can efficiently incorporate prior information into motion prediction schemes. In this paper, we present PathRover, a general setup designed for the integration of prior information into the motion planning algorithm of rapidly exploring random trees (RRT). Each suggested motion pathway comprises a sequence of low-energy clash-free conformations that satisfy an arbitrary number of prior information constraints. These constraints can be derived from experimental data or from expert intuition about the motion. The incorporation of prior information is very straightforward and significantly narrows down the vast search in the typically high-dimensional conformational space, leading to dramatic reduction in running time. To allow the use of state-of-the-art energy functions and conformational sampling, we have integrated this framework into Rosetta, an accurate protocol for diverse types of structural modeling. The suggested framework can serve as an effective complementary tool for molecular dynamics, Normal Mode Analysis, and other prevalent techniques for predicting motion in proteins. We applied our framework to three different model systems. We show that a limited set of experimentally motivated constraints may effectively bias the simulations toward diverse predicates in an outright fashion, from distance constraints to enforcement of loop closure. In particular, our analysis sheds light on mechanisms of protein domain swapping and on the role of different residues in the motion.

  17. Rapid sampling of molecular motions with prior information constraints.

    Directory of Open Access Journals (Sweden)

    Barak Raveh

    2009-02-01

    Full Text Available Proteins are active, flexible machines that perform a range of different functions. Innovative experimental approaches may now provide limited partial information about conformational changes along motion pathways of proteins. There is therefore a need for computational approaches that can efficiently incorporate prior information into motion prediction schemes. In this paper, we present PathRover, a general setup designed for the integration of prior information into the motion planning algorithm of rapidly exploring random trees (RRT. Each suggested motion pathway comprises a sequence of low-energy clash-free conformations that satisfy an arbitrary number of prior information constraints. These constraints can be derived from experimental data or from expert intuition about the motion. The incorporation of prior information is very straightforward and significantly narrows down the vast search in the typically high-dimensional conformational space, leading to dramatic reduction in running time. To allow the use of state-of-the-art energy functions and conformational sampling, we have integrated this framework into Rosetta, an accurate protocol for diverse types of structural modeling. The suggested framework can serve as an effective complementary tool for molecular dynamics, Normal Mode Analysis, and other prevalent techniques for predicting motion in proteins. We applied our framework to three different model systems. We show that a limited set of experimentally motivated constraints may effectively bias the simulations toward diverse predicates in an outright fashion, from distance constraints to enforcement of loop closure. In particular, our analysis sheds light on mechanisms of protein domain swapping and on the role of different residues in the motion.

  18. On-line Automated Sample Preparation-Capillary Gas Chromatography for the Analysis of Plasma Samples.

    NARCIS (Netherlands)

    Louter, A.J.H.; van der Wagt, R.A.C.A.; Brinkman, U.A.T.

    1995-01-01

    An automated sample preparation module, (the automated sample preparation with extraction columns, ASPEC), was interfaced with a capillary gas chromatograph (GC) by means of an on-column interface. The system was optimised for the determination of the antidepressant trazodone in plasma. The clean-up

  19. Cr(VI) generation during sample preparation of solid samples – A ...

    African Journals Online (AJOL)

    Cr(VI) generation during sample preparation of solid samples – A chromite ore case study. R.I Glastonbury, W van der Merwe, J.P Beukes, P.G van Zyl, G Lachmann, C.J.H Steenkamp, N.F Dawson, M.H Stewart ...

  20. Molecularly imprinted polymers for extraction of malachite green from fish samples prior to its determination by HPLC

    International Nuclear Information System (INIS)

    Li, Lu; Chen, Xiao-mei; Zhang, Hong-yuan; Lin, Yi-dong; Lin, Zheng-zhong; Huang, Zhi-yong; Lai, Zhu-zhi

    2015-01-01

    Molecularly imprinted polymer (MIP) particles for malachite green (MG) were prepared by emulsion polymerization using methacrylic acid as the functional monomer, ethylene glycol dimethacrylate as the cross-linker, and a combination of Span-80 and Tween-80 as an emulsifier. The MIP particles were characterized by SEM micrographs and FT-IR spectra. Their binding capacity for MG was evaluated based on kinetic and isothermal adsorption experiments and compared to non-imprinted polymer particles. Analytical figures of merit include an adsorption equilibrium time of 15 min, an adsorption capacity of 1.9 mg∙g -1 in acetonitrile-water (20:80), and an imprinting factor of 1.85. The MIP particles were successfully applied to the extraction of MG from fish samples spiked with MG and the other interfering substances prior to its determination of MG by HPLC. Spiked samples gave recoveries of MG that ranged from 86 to 104 %, much higher than that of the other interfering substance. (author)

  1. Current trends in sample preparation for cosmetic analysis.

    Science.gov (United States)

    Zhong, Zhixiong; Li, Gongke

    2017-01-01

    The widespread applications of cosmetics in modern life make their analysis particularly important from a safety point of view. There is a wide variety of restricted ingredients and prohibited substances that primarily influence the safety of cosmetics. Sample preparation for cosmetic analysis is a crucial step as the complex matrices may seriously interfere with the determination of target analytes. In this review, some new developments (2010-2016) in sample preparation techniques for cosmetic analysis, including liquid-phase microextraction, solid-phase microextraction, matrix solid-phase dispersion, pressurized liquid extraction, cloud point extraction, ultrasound-assisted extraction, and microwave digestion, are presented. Furthermore, the research and progress in sample preparation techniques and their applications in the separation and purification of allowed ingredients and prohibited substances are reviewed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Automated sample preparation station for studying self-diffusion in porous solids with NMR spectroscopy

    Science.gov (United States)

    Hedin, Niklas; DeMartin, Gregory J.; Reyes, Sebastián C.

    2006-03-01

    In studies of gas diffusion in porous solids with nuclear magnetic resonance (NMR) spectroscopy the sample preparation procedure becomes very important. An apparatus is presented here that pretreats the sample ex situ and accurately sets the desired pressure and temperature within the NMR tube prior to its introduction in the spectrometer. The gas manifold that supplies the NMR tube is also connected to a microbalance containing another portion of the same sample, which is kept at the same temperature as the sample in the NMR tube. This arrangement permits the simultaneous measurement of the adsorption loading on the sample, which is required for the interpretation of the NMR diffusion experiments. Furthermore, to ensure a good seal of the NMR tube, a hybrid valve design composed of titanium, a Teflon® seat, and Kalrez® O-rings is utilized. A computer controlled algorithm ensures the accuracy and reproducibility of all the procedures, enabling the NMR diffusion experiments to be performed at well controlled conditions of pressure, temperature, and amount of gas adsorbed on the porous sample.

  3. The Recent Developments in Sample Preparation for Mass Spectrometry-Based Metabolomics.

    Science.gov (United States)

    Gong, Zhi-Gang; Hu, Jing; Wu, Xi; Xu, Yong-Jiang

    2017-07-04

    Metabolomics is a critical member in systems biology. Although great progress has been achieved in metabolomics, there are still some problems in sample preparation, data processing and data interpretation. In this review, we intend to explore the roles, challenges and trends in sample preparation for mass spectrometry- (MS-) based metabolomics. The newly emerged sample preparation methods were also critically examined, including laser microdissection, in vivo sampling, dried blood spot, microwave, ultrasound and enzyme-assisted extraction, as well as microextraction techniques. Finally, we provide some conclusions and perspectives for sample preparation in MS-based metabolomics.

  4. Soil sample preparation using microwave digestion for uranium analysis

    International Nuclear Information System (INIS)

    Mohagheghi, Amir H.; Preston, Rose; Akbarzadeh, Mansoor; Bakthiar, Steven

    2000-01-01

    A new sample preparation procedure has been developed for digestion of soil samples for uranium analysis. The technique employs a microwave oven digestion system to digest the sample and to prepare it for separation chemistry and analysis. The method significantly reduces the volume of acids used, eliminates a large fraction of acid vapor emissions, and speeds up the analysis time. The samples are analyzed by four separate techniques: Gamma Spectrometry, Alpha Spectroscopy using the open digestion method, Kinetic Phosphorescence Analysis (KPA) using open digestion, and KPA by Microwave digestion technique. The results for various analytical methods are compared and used to confirm the validity of the new procedure. The details of the preparation technique along with its benefits are discussed

  5. Modified Activated Carbon Prepared from Acorn Shells as a New Solid-Phase Extraction Sorbent for the Preconcentration and Determination of Trace Amounts of Nickel in Food Samples Prior to Flame Atomic Absorption Spectrometry.

    Science.gov (United States)

    Ebrahimi, Bahram

    2017-03-01

    A new solid-phase extraction (SPE) sorbent was introduced based on acidic-modified (AM) activated carbon (AC) prepared from acorn shells of native oak trees in Kurdistan. Hydrochloric acid (15%, w/w) and nitric acid (32.5%, w/w) were used to condition and modify AC. The IR spectra of AC and AM-AC showed that AM lead to the formation of increasing numbers of acidic functional groups on AM-AC. AM-AC was used in the SPE method for the extraction and preconcentration of Ni+2 prior to flame atomic absorption spectrometric determination at ng/mL levels in model and real food samples. Effective parameters of the SPE procedure, such as the pH of the solutions, sorbent dosage, extraction time, sample volume, type of eluent, and matrix ions, were considered and optimized. An enrichment factor of 140 was obtained. The calibration curve was linear with an R2 of 0.997 in the concentration range of 1-220 ng/mL. The RSD was 5.67% (for n = 7), the LOD was 0.352 ng/mL, and relative recoveries in vegetable samples ranged from 96.7 to 103.7%.

  6. 7 CFR 61.34 - Drawing and preparation of sample.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Drawing and preparation of sample. 61.34 Section 61.34 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... Cottonseed Samplers § 61.34 Drawing and preparation of sample. Each licensed cottonseed sampler shall draw...

  7. New trends in sample preparation techniques for environmental analysis.

    Science.gov (United States)

    Ribeiro, Cláudia; Ribeiro, Ana Rita; Maia, Alexandra S; Gonçalves, Virgínia M F; Tiritan, Maria Elizabeth

    2014-01-01

    Environmental samples include a wide variety of complex matrices, with low concentrations of analytes and presence of several interferences. Sample preparation is a critical step and the main source of uncertainties in the analysis of environmental samples, and it is usually laborious, high cost, time consuming, and polluting. In this context, there is increasing interest in developing faster, cost-effective, and environmentally friendly sample preparation techniques. Recently, new methods have been developed and optimized in order to miniaturize extraction steps, to reduce solvent consumption or become solventless, and to automate systems. This review attempts to present an overview of the fundamentals, procedure, and application of the most recently developed sample preparation techniques for the extraction, cleanup, and concentration of organic pollutants from environmental samples. These techniques include: solid phase microextraction, on-line solid phase extraction, microextraction by packed sorbent, dispersive liquid-liquid microextraction, and QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe).

  8. Tooth enamel sample preparation using alkaline treatment in ESR dosimetry

    International Nuclear Information System (INIS)

    Yongzeng, Zhou; Jiadong, Wang; Xiaomei, Jia; Ke, Wu; Jianbo, Cong

    2002-01-01

    Tooth enamel sample preparation using alkaline treatment was studied and compared with traditional mechanical method in this paper. 20 adult teeth were used. Samples were placed into NaOH solution. This method requires 4-5 weeks and the enamel was separated from dentin. Experimental results show that 8M NaOH was appropriate for separating enamel from dentin and that there is no difference in background signal relative intensity between samples prepared by mechanical and by chemical methods. There is also no difference in radiosensitivity between samples prepared by two methods mentioned above. Dose response curve for tooth enamel samples isolated by 8M NaOH solution was obtained

  9. Sample preparation for special PIE-techniques at ITU

    International Nuclear Information System (INIS)

    Toscano, E.H.; Manzel, R.

    2002-01-01

    Several sample preparation techniques were developed and installed in hot cells. The techniques were conceived to evaluate the performance of highly burnt fuel rods and include: (a) a device for the removal of the fuel, (b) a method for the preparation of the specimen ends for the welding of new end caps and for the careful cleaning of samples for Transmission Electron Microscopy and Glow Discharge Mass Spectroscopy, (c) a sample pressurisation device for long term creep tests, and (d) a diameter measuring device for creep or burst samples. Examples of the determination of the mechanical properties, the behaviour under transient conditions and for the assessment of the corrosion behaviour of high burnup cladding materials are presented. (author)

  10. High-throughput automated microfluidic sample preparation for accurate microbial genomics.

    Science.gov (United States)

    Kim, Soohong; De Jonghe, Joachim; Kulesa, Anthony B; Feldman, David; Vatanen, Tommi; Bhattacharyya, Roby P; Berdy, Brittany; Gomez, James; Nolan, Jill; Epstein, Slava; Blainey, Paul C

    2017-01-27

    Low-cost shotgun DNA sequencing is transforming the microbial sciences. Sequencing instruments are so effective that sample preparation is now the key limiting factor. Here, we introduce a microfluidic sample preparation platform that integrates the key steps in cells to sequence library sample preparation for up to 96 samples and reduces DNA input requirements 100-fold while maintaining or improving data quality. The general-purpose microarchitecture we demonstrate supports workflows with arbitrary numbers of reaction and clean-up or capture steps. By reducing the sample quantity requirements, we enabled low-input (∼10,000 cells) whole-genome shotgun (WGS) sequencing of Mycobacterium tuberculosis and soil micro-colonies with superior results. We also leveraged the enhanced throughput to sequence ∼400 clinical Pseudomonas aeruginosa libraries and demonstrate excellent single-nucleotide polymorphism detection performance that explained phenotypically observed antibiotic resistance. Fully-integrated lab-on-chip sample preparation overcomes technical barriers to enable broader deployment of genomics across many basic research and translational applications.

  11. Consensus guidelines for the use of bowel preparation prior to colonic diagnostic procedures: colonoscopy and small bowel video capsule endoscopy

    NARCIS (Netherlands)

    Mathus-Vliegen, Elisabeth; Pellisé, Maria; Heresbach, Denis; Fischbach, Wolfgang; Dixon, Tricia; Belsey, Jonathan; Parente, Fabrizio; Rio-Tinto, Ricardo; Brown, Alistair; Toth, Ervin; Crosta, Cristiano; Layer, Peter; Epstein, Owen; Boustiere, Christian

    2013-01-01

    Adequate bowel preparation prior to colonic diagnostic procedures is essential to ensure adequate visualisation. This consensus aims to provide guidance as to the appropriate use of bowel preparation for a range of defined clinical circumstances. A consensus group from across Europe was convened and

  12. Sample preparations for spark source mass spectrography

    International Nuclear Information System (INIS)

    Catlett, C.W.; Rollins, M.B.; Griffin, E.B.; Dorsey, J.G.

    1977-10-01

    Methods have been developed for the preparation of various materials for spark source mass spectrography. The essential features of these preparations (all which can provide adequate precision in a cost-effective manner) consist in obtaining spark-stable electrode sample pieces, a common matrix, a reduction of anomolous effects in the spark, the incorporation of a suitable internal standard for plate response normalization, and a reduction in time

  13. Present status of NMCC and sample preparation method for bio-samples

    International Nuclear Information System (INIS)

    Futatsugawa, S.; Hatakeyama, S.; Saitou, S.; Sera, K.

    1993-01-01

    In NMCC(Nishina Memorial Cyclotron Center) we are doing researches on PET of nuclear medicine (Positron Emission Computed Tomography) and PIXE analysis (Particle Induced X-ray Emission) using a small cyclotron of compactly designed. The NMCC facilities have been opened to researchers of other institutions since April 1993. The present status of NMCC is described. Bio-samples (medical samples, plants, animals and environmental samples) have mainly been analyzed by PIXE in NMCC. Small amounts of bio-samples for PIXE are decomposed quickly and easily in a sealed PTFE (polytetrafluoroethylene) vessel with a microwave oven. This sample preparation method of bio-samples also is described. (author)

  14. Finding even more anthropogenic indicators in mildly prepared sediment samples

    DEFF Research Database (Denmark)

    Enevold, Renée; Odgaard, Bent Vad

    2016-01-01

    be worth the effort to prepare the NPP samples with as mild a preparation method as possible. We have mildly prepared NPP samples from a small forest hollow, Tårup Lund, Denmark. From the recovered NPP assemblages we attempt identifying anthropogenic indicators by comparing to the environmental information......NPPs in anthropogenic soils and archaeological samples are often numerous in types as well as in abundance. Preparing these soil samples with methods based on acid digestion holds the potential of severe bias leaving the NPP assemblages devoid of acid vulnerable NPPs. In many cases it might...... derived from sediment, pollen and macrofossil analyses. The sediment from the forest hollow encompasses environmental information from the last 6000 years, including a period of locally intense pastoral and/or agricultural activity during the Iron Age. Keywords: NPP diversity, forest hollow, anthropogenic...

  15. Sampling, storage and sample preparation procedures for X ray fluorescence analysis of environmental materials

    International Nuclear Information System (INIS)

    1997-06-01

    X ray fluorescence (XRF) method is one of the most commonly used nuclear analytical technique because of its multielement and non-destructive character, speed, economy and ease of operation. From the point of view of quality assurance practices, sampling and sample preparation procedures are the most crucial steps in all analytical techniques, (including X ray fluorescence) applied for the analysis of heterogeneous materials. This technical document covers recent modes of the X ray fluorescence method and recent developments in sample preparation techniques for the analysis of environmental materials. Refs, figs, tabs

  16. Influences of different sample preparation methods on tooth enamel ESR signals

    International Nuclear Information System (INIS)

    Zhang Wenyi; Jiao Ling; Zhang Liang'an; Pan Zhihong; Zeng Hongyu

    2005-01-01

    Objective: To study the influences of different sample preparation methods on tooth enamel ESR signals in order to reduce the effect of dentine on their sensitivities to radiation. Methods: The enamel was separated from dentine of non-irradiated adult teeth by mechanical, chemical, or both methods. The samples of different preparations were scanned by an ESR spectrometer before and after irradiation. Results: The response of ESR signals of samples prepared with different methods to radiation dose was significantly different. Conclusion: The selection of sample preparation method is very important for dose reconstruction by tooth enamel ESR dosimetry, especially in the low dose range. (authors)

  17. Global metabolite analysis of yeast: evaluation of sample preparation methods

    DEFF Research Database (Denmark)

    Villas-Bôas, Silas Granato; Højer-Pedersen, Jesper; Åkesson, Mats Fredrik

    2005-01-01

    Sample preparation is considered one of the limiting steps in microbial metabolome analysis. Eukaryotes and prokaryotes behave very differently during the several steps of classical sample preparation methods for analysis of metabolites. Even within the eukaryote kingdom there is a vast diversity...

  18. Fluidics platform and method for sample preparation and analysis

    Science.gov (United States)

    Benner, W. Henry; Dzenitis, John M.; Bennet, William J.; Baker, Brian R.

    2014-08-19

    Herein provided are fluidics platform and method for sample preparation and analysis. The fluidics platform is capable of analyzing DNA from blood samples using amplification assays such as polymerase-chain-reaction assays and loop-mediated-isothermal-amplification assays. The fluidics platform can also be used for other types of assays and analyzes. In some embodiments, a sample in a sealed tube can be inserted directly. The following isolation, detection, and analyzes can be performed without a user's intervention. The disclosed platform may also comprises a sample preparation system with a magnetic actuator, a heater, and an air-drying mechanism, and fluid manipulation processes for extraction, washing, elution, assay assembly, assay detection, and cleaning after reactions and between samples.

  19. Combining Electrochemical Sensors with Miniaturized Sample Preparation for Rapid Detection in Clinical Samples

    Science.gov (United States)

    Bunyakul, Natinan; Baeumner, Antje J.

    2015-01-01

    Clinical analyses benefit world-wide from rapid and reliable diagnostics tests. New tests are sought with greatest demand not only for new analytes, but also to reduce costs, complexity and lengthy analysis times of current techniques. Among the myriad of possibilities available today to develop new test systems, amperometric biosensors are prominent players—best represented by the ubiquitous amperometric-based glucose sensors. Electrochemical approaches in general require little and often enough only simple hardware components, are rugged and yet provide low limits of detection. They thus offer many of the desirable attributes for point-of-care/point-of-need tests. This review focuses on investigating the important integration of sample preparation with (primarily electrochemical) biosensors. Sample clean up requirements, miniaturized sample preparation strategies, and their potential integration with sensors will be discussed, focusing on clinical sample analyses. PMID:25558994

  20. Sample selection, preparation methods, and the apparent tensile properties of silkworm (B. mori) cocoon silk.

    Science.gov (United States)

    Reed, Emily J; Bianchini, Lindsay L; Viney, Christopher

    2012-06-01

    Reported literature values of the tensile properties of natural silk cover a wide range. While much of this inconsistency is the result of variability that is intrinsic to silk, some is also a consequence of differences in the way that silk is prepared for tensile tests. Here we explore how measured mechanical properties of Bombyx mori cocoon silk are affected by two intrinsic factors (the location from which the silk is collected within the cocoon, and the color of the silk), and two extrinsic factors (the storage conditions prior to testing, and different styles of reeling the fiber). We find that extrinsic and therefore controllable factors can affect the properties more than the intrinsic ones studied. Our results suggest that enhanced inter-laboratory collaborations, that lead to standardized sample collection, handling, and storage protocols prior to mechanical testing, would help to decrease unnecessary (and complicating) variation in reported tensile properties. Copyright © 2011 Wiley Periodicals, Inc.

  1. Sample preparation techniques in trace element analysis by X-ray emission spectroscopy

    International Nuclear Information System (INIS)

    Valkovic, V.

    1983-11-01

    The report, written under a research contract with the IAEA, contains a detailed presentation of the most difficult problem encountered in the trace element analysis by methods of the X-ray emission spectroscopy, namely the sample preparation techniques. The following items are covered. Sampling - with specific consideration of aerosols, water, soil, biological materials, petroleum and its products, storage of samples and their handling. Pretreatment of samples - preconcentration, ashing, solvent extraction, ion exchange and electrodeposition. Sample preparations for PIXE - analysis - backings, target uniformity and homogeneity, effects of irradiation, internal standards and specific examples of preparation (aqueous, biological, blood serum and solid samples). Sample preparations for radioactive sources or tube excitation - with specific examples (water, liquid and solid samples, soil, geological, plants and tissue samples). Finally, the problem of standards and reference materials, as well as that of interlaboratory comparisons, is discussed

  2. Sample Preparation for Mass Spectrometry Imaging of Plant Tissues: A Review

    Science.gov (United States)

    Dong, Yonghui; Li, Bin; Malitsky, Sergey; Rogachev, Ilana; Aharoni, Asaph; Kaftan, Filip; Svatoš, Aleš; Franceschi, Pietro

    2016-01-01

    Mass spectrometry imaging (MSI) is a mass spectrometry based molecular ion imaging technique. It provides the means for ascertaining the spatial distribution of a large variety of analytes directly on tissue sample surfaces without any labeling or staining agents. These advantages make it an attractive molecular histology tool in medical, pharmaceutical, and biological research. Likewise, MSI has started gaining popularity in plant sciences; yet, information regarding sample preparation methods for plant tissues is still limited. Sample preparation is a crucial step that is directly associated with the quality and authenticity of the imaging results, it therefore demands in-depth studies based on the characteristics of plant samples. In this review, a sample preparation pipeline is discussed in detail and illustrated through selected practical examples. In particular, special concerns regarding sample preparation for plant imaging are critically evaluated. Finally, the applications of MSI techniques in plants are reviewed according to different classes of plant metabolites. PMID:26904042

  3. Sample Preparation for Mass Spectrometry Imaging of Plant Tissues: A Review.

    Science.gov (United States)

    Dong, Yonghui; Li, Bin; Malitsky, Sergey; Rogachev, Ilana; Aharoni, Asaph; Kaftan, Filip; Svatoš, Aleš; Franceschi, Pietro

    2016-01-01

    Mass spectrometry imaging (MSI) is a mass spectrometry based molecular ion imaging technique. It provides the means for ascertaining the spatial distribution of a large variety of analytes directly on tissue sample surfaces without any labeling or staining agents. These advantages make it an attractive molecular histology tool in medical, pharmaceutical, and biological research. Likewise, MSI has started gaining popularity in plant sciences; yet, information regarding sample preparation methods for plant tissues is still limited. Sample preparation is a crucial step that is directly associated with the quality and authenticity of the imaging results, it therefore demands in-depth studies based on the characteristics of plant samples. In this review, a sample preparation pipeline is discussed in detail and illustrated through selected practical examples. In particular, special concerns regarding sample preparation for plant imaging are critically evaluated. Finally, the applications of MSI techniques in plants are reviewed according to different classes of plant metabolites.

  4. 15N sample preparation for mass spectroscopy analysis

    International Nuclear Information System (INIS)

    Trivelin, P.C.O.; Salati, E.; Matsui, E.

    1973-01-01

    Technics for preparing 15 N samples to be analised is presented. Dumas method and oxidation by sodium hypobromite method are described in order to get the appropriate sample. Method to calculate 15 N ratio from mass spectrometry dates is also discussed [pt

  5. Preparation of archaeological samples for its dating by thermoluminescence

    International Nuclear Information System (INIS)

    Mejia F, D.

    2000-01-01

    The present work shows the results of the preparation of archaeological samples for their dating by thermoluminescence (Tl) using the Fine grain technique established by Zimmerman but with the varying of such preparation was realized in normal daylight conditions, only the taking of the Tl readings were realized in dark room and red light. In the chapter 1 basic concepts are described about: matter constitution, radioactivity, units and radiation magnitudes, and thermoluminescence. In the chapter 2 some theoretical aspects on dating are showed. It is described how realizing the samples collection, the fine grain method, the determination of the accumulated dose through the years or paleodoses (P=Q+I) by mean of the increasing to obtain the dose equivalent dose (Q) and the signal regeneration method to obtain the correction factor by supra linearity (1), the determination of the annual dose rate to apply the age equation and the evaluation of the age uncertainty with the error limits. The development of experimental part with samples from the archaeological site named Edzna in Campeche, Mexico is described in the chapter 3. The results are presented in the chapter 4. It was obtained an age for the sample named CH7 it was obtained an age of 389 ± years. In conclusion the preparation of the archaeological samples for their dating by Tl in the conditions before mentioned is reliable, but they must be realized more studies with samples of well known age, preparing them in normal daylight conditions and simultaneously in dark room with red light. In order to observe how respond the minerals present in the sample at different dose rapidity, the same samples must be radiated with radiation sources with different dose rate. (Author)

  6. Sample preparation and EFTEM of Meat Samples for Nanoparticle Analysis in Food

    International Nuclear Information System (INIS)

    Lari, L; Dudkiewicz, A

    2014-01-01

    Nanoparticles are used in industry for personal care products and the preparation of food. In the latter application, their functions include the prevention of microbes' growth, increase of the foods nutritional value and sensory quality. EU regulations require a risk assessment of the nanoparticles used in foods and food contact materials before the products can reach the market. However, availability of validated analytical methodologies for detection and characterisation of the nanoparticles in food hampers appropriate risk assessment. As part of a research on the evaluation of the methods for screening and quantification of Ag nanoparticles in meat we have tested a new TEM sample preparation alternative to resin embedding and cryo-sectioning. Energy filtered TEM analysis was applied to evaluate thickness and the uniformity of thin meat layers acquired at increasing input of the sample demonstrating that the protocols used ensured good stability under the electron beam, reliable sample concentration and reproducibility

  7. Sample preparation and EFTEM of Meat Samples for Nanoparticle Analysis in Food

    Science.gov (United States)

    Lari, L.; Dudkiewicz, A.

    2014-06-01

    Nanoparticles are used in industry for personal care products and the preparation of food. In the latter application, their functions include the prevention of microbes' growth, increase of the foods nutritional value and sensory quality. EU regulations require a risk assessment of the nanoparticles used in foods and food contact materials before the products can reach the market. However, availability of validated analytical methodologies for detection and characterisation of the nanoparticles in food hampers appropriate risk assessment. As part of a research on the evaluation of the methods for screening and quantification of Ag nanoparticles in meat we have tested a new TEM sample preparation alternative to resin embedding and cryo-sectioning. Energy filtered TEM analysis was applied to evaluate thickness and the uniformity of thin meat layers acquired at increasing input of the sample demonstrating that the protocols used ensured good stability under the electron beam, reliable sample concentration and reproducibility.

  8. Final LDRD report : development of sample preparation methods for ChIPMA-based imaging mass spectrometry of tissue samples.

    Energy Technology Data Exchange (ETDEWEB)

    Maharrey, Sean P.; Highley, Aaron M.; Behrens, Richard, Jr.; Wiese-Smith, Deneille

    2007-12-01

    The objective of this short-term LDRD project was to acquire the tools needed to use our chemical imaging precision mass analyzer (ChIPMA) instrument to analyze tissue samples. This effort was an outgrowth of discussions with oncologists on the need to find the cellular origin of signals in mass spectra of serum samples, which provide biomarkers for ovarian cancer. The ultimate goal would be to collect chemical images of biopsy samples allowing the chemical images of diseased and nondiseased sections of a sample to be compared. The equipment needed to prepare tissue samples have been acquired and built. This equipment includes an cyro-ultramicrotome for preparing thin sections of samples and a coating unit. The coating unit uses an electrospray system to deposit small droplets of a UV-photo absorbing compound on the surface of the tissue samples. Both units are operational. The tissue sample must be coated with the organic compound to enable matrix assisted laser desorption/ionization (MALDI) and matrix enhanced secondary ion mass spectrometry (ME-SIMS) measurements with the ChIPMA instrument Initial plans to test the sample preparation using human tissue samples required development of administrative procedures beyond the scope of this LDRD. Hence, it was decided to make two types of measurements: (1) Testing the spatial resolution of ME-SIMS by preparing a substrate coated with a mixture of an organic matrix and a bio standard and etching a defined pattern in the coating using a liquid metal ion beam, and (2) preparing and imaging C. elegans worms. Difficulties arose in sectioning the C. elegans for analysis and funds and time to overcome these difficulties were not available in this project. The facilities are now available for preparing biological samples for analysis with the ChIPMA instrument. Some further investment of time and resources in sample preparation should make this a useful tool for chemical imaging applications.

  9. Sample preparation composite and replicate strategy for assay of solid oral drug products.

    Science.gov (United States)

    Harrington, Brent; Nickerson, Beverly; Guo, Michele Xuemei; Barber, Marc; Giamalva, David; Lee, Carlos; Scrivens, Garry

    2014-12-16

    In pharmaceutical analysis, the results of drug product assay testing are used to make decisions regarding the quality, efficacy, and stability of the drug product. In order to make sound risk-based decisions concerning drug product potency, an understanding of the uncertainty of the reportable assay value is required. Utilizing the most restrictive criteria in current regulatory documentation, a maximum variability attributed to method repeatability is defined for a drug product potency assay. A sampling strategy that reduces the repeatability component of the assay variability below this predefined maximum is demonstrated. The sampling strategy consists of determining the number of dosage units (k) to be prepared in a composite sample of which there may be a number of equivalent replicate (r) sample preparations. The variability, as measured by the standard error (SE), of a potency assay consists of several sources such as sample preparation and dosage unit variability. A sampling scheme that increases the number of sample preparations (r) and/or number of dosage units (k) per sample preparation will reduce the assay variability and thus decrease the uncertainty around decisions made concerning the potency of the drug product. A maximum allowable repeatability component of the standard error (SE) for the potency assay is derived using material in current regulatory documents. A table of solutions for the number of dosage units per sample preparation (r) and number of replicate sample preparations (k) is presented for any ratio of sample preparation and dosage unit variability.

  10. Use of robotic systems for radiochemical sample changing and for analytical sample preparation

    International Nuclear Information System (INIS)

    Delmastro, J.R.; Hartenstein, S.D.; Wade, M.A.

    1989-01-01

    Two uses of the Perkin-Elmer (PE) robotic system will be presented. In the first, a PE robot functions as an automatic sample changer for up to five low energy photon spectrometry (LEPS) detectors operated with a Nuclear Data ND 6700 system. The entire system, including the robot, is controlled by an IBM PC-AT using software written in compiled BASIC. Problems associated with the development of the system and modifications to the robot will be presented. In the second, an evaluation study was performed to assess the abilities of the PE robotic system for performing complex analytical sample preparation procedures. For this study, a robotic system based upon the PE robot and auxiliary devices was constructed and programmed to perform the preparation of final product samples (UO 3 ) for accountability and impurity specification analyses. These procedures require sample dissolution, dilution, and liquid-liquid extraction steps. The results of an in-depth evaluation of all system components will be presented

  11. Sample preparation of energy materials for X-ray nanotomography with micromanipulation.

    Science.gov (United States)

    Chen-Wiegart, Yu-chen Karen; Camino, Fernando E; Wang, Jun

    2014-06-06

    X-ray nanotomography presents an unprecedented opportunity to study energy storage/conversion materials at nanometer scales in three dimensions, with both elemental and chemical sensitivity. A critical step in obtaining high-quality X-ray nanotomography data is reliable sample preparation to ensure that the entire sample fits within the field of view of the X-ray microscope. Although focused-ion-beam lift-out has previously been used for large sample (few to tens of microns) preparation, a difficult undercut and lift-out procedure results in a time-consuming sample preparation process. Herein, we propose a much simpler and direct sample preparation method to resolve the issues that block the view of the sample base after milling and during the lift-out process. This method is applied on a solid-oxide fuel cell and a lithium-ion battery electrode, before numerous critical 3D morphological parameters are extracted, which are highly relevant to their electrochemical performance. A broad application of this method for microstructure study with X-ray nanotomography is discussed and presented. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Comparison of sample preparation procedures on metal(loid) fractionation patterns in lichens.

    Science.gov (United States)

    Kroukamp, E M; Godeto, T W; Forbes, P B C

    2017-08-13

    The effects of different sample preparation strategies and storage on metal(loid) fractionation trends in plant material is largely underresearched. In this study, a bulk sample of lichen Parmotrema austrosinense (Zahlbr.) Hale was analysed for its total extractable metal(loid) content by ICP-MS, and was determined to be adequately homogenous (sample were prepared utilising a range of sample preservation techniques and subjected to a modified sequential extraction procedure or to total metal extraction. Both experiments were repeated after 1-month storage at 4 °C. Cryogenic freezing gave the best reproducibility for total extractable elemental concentrations between months, indicating this to be the most suitable method of sample preparation in such studies. The combined extraction efficiencies were >82% for As, Cu, Mn, Pb, Sr and Zn but poor for other elements, where sample preparation strategies 'no sample preparation' and 'dried in a desiccator' had the best extraction recoveries. Cryogenic freezing procedures had a significantly (p sample cleaning and preservation when species fractionation patterns are of interest. This study also shows that the assumption that species stability can be ensured through cryopreservation and freeze drying techniques needs to be revisited.

  13. Tolerance and effectiveness of two methods for colonic preparation prior to surgery: Fosfoda® vs Solución Evacuante Bohm®

    Directory of Open Access Journals (Sweden)

    Silvia C. Egea González

    2004-12-01

    Full Text Available An adequate mechanical colon preparation prior to abdominal surgery is mandatory in order to prevent infectious and mechanical complications after surgery. The standard strategies for mechanical bowel preparation are based in the use of oral solutions.Aim: To compare effectiveness, security and tolerance of two methods for mechanical bowel preparation (Fosfosoda® and Solución Evacuante Bohm®.Methodology: Descriptive study of the prospective cohort of patients admitted for surgery requiring previous bowel preparation in the Fundación Hospital Alcorcón (Madrid, between October 01 and June 02 Results: Within patients who received Fosfosoda® as preparative solution (24/47%, 66% did not experience associated symthomatology at all, but 5 (21% experienced vomiting. The bowel cleaning quality was classified as good or excellent in 92% of them according to nursing evaluation and as excellent in 70% according to surgeon evaluation. Due to an inadequate bowel cleaning 2 patients (8% required an enema administration prior to surgery. Within patients who were treated with Solución Evacuante Bohm® (27/53%, 57% experienced no associated symthoms, 2 of them (7,5% experienced vomiting, the bowel cleaning quality was classified as good/excellent in 85% by nurses and as excellent in 73% by surgeons. Within this group 3 (11% patients required an enema administration prior to surgery.Conclusions: Bowel cleaning was slightly better in patients who were treated with Fosfoda®, nevertheless the tolerance was better within patients who received Solution Evacuante Bohm®.

  14. Choice and preparation of standard samples for X-ray spectral microanalysis

    International Nuclear Information System (INIS)

    Gavrilenko, I.S.; Surzhko, V.F.

    1989-01-01

    Choice, preparation and certification of standard samples for X-ray spectral microanalysis are considered. Requirements for standard samples in terms of concentration and volume, porosity, corrosion, conductivity distribution are formulated. Stages of sample preparation process, including composition choice, heat treatment, section production, certification, are considered in detail. The choice of composition is based on studying phase equilibrium diagrams, subdivided into 6 types

  15. Tolerance and effectiveness of two methods for colonic preparation prior to surgery: Fosfoda® vs Solución Evacuante Bohm®

    OpenAIRE

    Silvia C. Egea González; Enriqueta Perales Martínez; Ana Zomeño Delgado; Mónica Domínguez Barriales

    2004-01-01

    An adequate mechanical colon preparation prior to abdominal surgery is mandatory in order to prevent infectious and mechanical complications after surgery. The standard strategies for mechanical bowel preparation are based in the use of oral solutions.Aim: To compare effectiveness, security and tolerance of two methods for mechanical bowel preparation (Fosfosoda® and Solución Evacuante Bohm®).Methodology: Descriptive study of the prospective cohort of patients admitted for surgery requiring p...

  16. Novel strategies for sample preparation in forensic toxicology.

    Science.gov (United States)

    Samanidou, Victoria; Kovatsi, Leda; Fragou, Domniki; Rentifis, Konstantinos

    2011-09-01

    This paper provides a review of novel strategies for sample preparation in forensic toxicology. The review initially outlines the principle of each technique, followed by sections addressing each class of abused drugs separately. The novel strategies currently reviewed focus on the preparation of various biological samples for the subsequent determination of opiates, benzodiazepines, amphetamines, cocaine, hallucinogens, tricyclic antidepressants, antipsychotics and cannabinoids. According to our experience, these analytes are the most frequently responsible for intoxications in Greece. The applications of techniques such as disposable pipette extraction, microextraction by packed sorbent, matrix solid-phase dispersion, solid-phase microextraction, polymer monolith microextraction, stir bar sorptive extraction and others, which are rapidly gaining acceptance in the field of toxicology, are currently reviewed.

  17. TEM sample preparation by FIB for carbon nanotube interconnects

    International Nuclear Information System (INIS)

    Ke, Xiaoxing; Bals, Sara; Romo Negreira, Ainhoa; Hantschel, Thomas; Bender, Hugo; Van Tendeloo, Gustaaf

    2009-01-01

    A powerful method to study carbon nanotubes (CNTs) grown in patterned substrates for potential interconnects applications is transmission electron microscopy (TEM). However, high-quality TEM samples are necessary for such a study. Here, TEM specimen preparation by focused ion beam (FIB) has been used to obtain lamellae of patterned samples containing CNTs grown inside contact holes. A dual-cap Pt protection layer and an extensive 5 kV cleaning procedure are applied in order to preserve the CNTs and avoid deterioration during milling. TEM results show that the inner shell structure of the carbon nanotubes has been preserved, which proves that focused ion beam is a useful technique to prepare TEM samples of CNT interconnects.

  18. TEM sample preparation by FIB for carbon nanotube interconnects

    Energy Technology Data Exchange (ETDEWEB)

    Ke, Xiaoxing, E-mail: xiaoxing.ke@ua.ac.be [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Bals, Sara [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Romo Negreira, Ainhoa [IMEC, Kapeldreef 75, B-3001 Leuven (Belgium); Metallurgy and Materials Engineering Department, KU Leuven, Kasteelpark Arenberg 44, Leuven B-3001 (Belgium); Hantschel, Thomas; Bender, Hugo [IMEC, Kapeldreef 75, B-3001 Leuven (Belgium); Van Tendeloo, Gustaaf [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium)

    2009-10-15

    A powerful method to study carbon nanotubes (CNTs) grown in patterned substrates for potential interconnects applications is transmission electron microscopy (TEM). However, high-quality TEM samples are necessary for such a study. Here, TEM specimen preparation by focused ion beam (FIB) has been used to obtain lamellae of patterned samples containing CNTs grown inside contact holes. A dual-cap Pt protection layer and an extensive 5 kV cleaning procedure are applied in order to preserve the CNTs and avoid deterioration during milling. TEM results show that the inner shell structure of the carbon nanotubes has been preserved, which proves that focused ion beam is a useful technique to prepare TEM samples of CNT interconnects.

  19. Standardised Resting Time Prior to Blood Sampling and Diurnal Variation Associated with Risk of Patient Misclassification

    DEFF Research Database (Denmark)

    Bøgh Andersen, Ida; Brasen, Claus L.; Christensen, Henry

    2015-01-01

    .9×10-7) and sodium (p = 8.7×10-16). Only TSH and albumin were clinically significantly influenced by diurnal variation. Resting time had no clinically significant effect. CONCLUSIONS: We found no need for resting 15 minutes prior to blood sampling. However, diurnal variation was found to have a significant......BACKGROUND: According to current recommendations, blood samples should be taken in the morning after 15 minutes' resting time. Some components exhibit diurnal variation and in response to pressures to expand opening hours and reduce waiting time, the aims of this study were to investigate...... the impact of resting time prior to blood sampling and diurnal variation on biochemical components, including albumin, thyrotropin (TSH), total calcium and sodium in plasma. METHODS: All patients referred to an outpatient clinic for blood sampling were included in the period Nov 2011 until June 2014 (opening...

  20. Supporting Sampling and Sample Preparation Tools for Isotope and Nuclear Analysis

    International Nuclear Information System (INIS)

    2016-03-01

    Nuclear and related techniques can help develop climate-smart agricultural practices by optimizing water and nutrient use efficiency, assessing organic carbon sequestration in soil, and assisting in the evaluation of soil erosion control measures. Knowledge on the behaviour of radioactive materials in soil, water and foodstuffs is also essential in enhancing nuclear emergency preparedness and response. Appropriate sampling and sample preparation are the first steps to ensure the quality and effective use of the measurements and this publication provides comprehensive detail on the necessary steps

  1. Selecting Sample Preparation Workflows for Mass Spectrometry-Based Proteomic and Phosphoproteomic Analysis of Patient Samples with Acute Myeloid Leukemia.

    Science.gov (United States)

    Hernandez-Valladares, Maria; Aasebø, Elise; Selheim, Frode; Berven, Frode S; Bruserud, Øystein

    2016-08-22

    Global mass spectrometry (MS)-based proteomic and phosphoproteomic studies of acute myeloid leukemia (AML) biomarkers represent a powerful strategy to identify and confirm proteins and their phosphorylated modifications that could be applied in diagnosis and prognosis, as a support for individual treatment regimens and selection of patients for bone marrow transplant. MS-based studies require optimal and reproducible workflows that allow a satisfactory coverage of the proteome and its modifications. Preparation of samples for global MS analysis is a crucial step and it usually requires method testing, tuning and optimization. Different proteomic workflows that have been used to prepare AML patient samples for global MS analysis usually include a standard protein in-solution digestion procedure with a urea-based lysis buffer. The enrichment of phosphopeptides from AML patient samples has previously been carried out either with immobilized metal affinity chromatography (IMAC) or metal oxide affinity chromatography (MOAC). We have recently tested several methods of sample preparation for MS analysis of the AML proteome and phosphoproteome and introduced filter-aided sample preparation (FASP) as a superior methodology for the sensitive and reproducible generation of peptides from patient samples. FASP-prepared peptides can be further fractionated or IMAC-enriched for proteome or phosphoproteome analyses. Herein, we will review both in-solution and FASP-based sample preparation workflows and encourage the use of the latter for the highest protein and phosphorylation coverage and reproducibility.

  2. Development of sample preparation method for honey analysis using PIXE

    International Nuclear Information System (INIS)

    Saitoh, Katsumi; Chiba, Keiko; Sera, Koichiro

    2008-01-01

    We developed an original preparation method for honey samples (samples in paste-like state) specifically designed for PIXE analysis. The results of PIXE analysis of thin targets prepared by adding a standard containing nine elements to honey samples demonstrated that the preparation method bestowed sufficient accuracy on quantitative values. PIXE analysis of 13 kinds of honey was performed, and eight mineral components (Si, P, S, K, Ca, Mn, Cu and Zn) were detected in all honey samples. The principal mineral components were K and Ca, and the quantitative value for K accounted for the majority of the total value for mineral components. K content in honey varies greatly depending on the plant source. Chestnuts had the highest K content. In fact, it was 2-3 times that of Manuka, which is known as a high quality honey. K content of false-acacia, which is produced in the greatest abundance, was 1/20 that of chestnuts. (author)

  3. Witness sample preparation for measuring antireflection coatings.

    Science.gov (United States)

    Willey, Ronald R

    2014-02-01

    Measurement of antireflection coating of witness samples from across the worldwide industry has been shown to have excess variability from a sampling taken for the OSA Topical Meeting on Optical Interference Coatings: Measurement Problem. Various sample preparation techniques have been discussed with their limitations, and a preferred technique is recommended with its justification, calibration procedures, and limitations. The common practice of grinding the second side to reduce its reflection is less than satisfactory. One recommended practice is to paint the polished second side, which reduces its reflection to almost zero. A method to evaluate the suitability of given paints is also described.

  4. Sample preparation method for scanning force microscopy

    CERN Document Server

    Jankov, I R; Szente, R N; Carreno, M N P; Swart, J W; Landers, R

    2001-01-01

    We present a method of sample preparation for studies of ion implantation on metal surfaces. The method, employing a mechanical mask, is specially adapted for samples analysed by Scanning Force Microscopy. It was successfully tested on polycrystalline copper substrates implanted with phosphorus ions at an acceleration voltage of 39 keV. The changes of the electrical properties of the surface were measured by Kelvin Probe Force Microscopy and the surface composition was analysed by Auger Electron Spectroscopy.

  5. Is Mars Sample Return Required Prior to Sending Humans to Mars?

    Science.gov (United States)

    Carr, Michael; Abell, Paul; Allwood, Abigail; Baker, John; Barnes, Jeff; Bass, Deborah; Beaty, David; Boston, Penny; Brinkerhoff, Will; Budney, Charles; hide

    2012-01-01

    Prior to potentially sending humans to the surface of Mars, it is fundamentally important to return samples from Mars. Analysis in Earth's extensive scientific laboratories would significantly reduce the risk of human Mars exploration and would also support the science and engineering decisions relating to the Mars human flight architecture. The importance of measurements of any returned Mars samples range from critical to desirable, and in all cases these samples will would enhance our understanding of the Martian environment before potentially sending humans to that alien locale. For example, Mars sample return (MSR) could yield information that would enable human exploration related to 1) enabling forward and back planetary protection, 2) characterizing properties of Martian materials relevant for in situ resource utilization (ISRU), 3) assessing any toxicity of Martian materials with respect to human health and performance, and 4) identifying information related to engineering surface hazards such as the corrosive effect of the Martian environment. In addition, MSR would be engineering 'proof of concept' for a potential round trip human mission to the planet, and a potential model for international Mars exploration.

  6. Status report of AMS sample preparation laboratory at GADAM Centre, Gliwice, Poland

    Energy Technology Data Exchange (ETDEWEB)

    Piotrowska, N., E-mail: natalia.piotrowska@polsl.pl [GADAM Centre of Excellence, Department of Radioisotopes, Institute of Physics, Silesian University of Technology, Gliwice (Poland)

    2013-01-15

    The laboratory for {sup 14}C AMS sample preparation in the Gliwice Radiocarbon Laboratory has gradually evolved since its start in 1999 to cater for an increase in volume and variety of radiocarbon dating samples. To date, nearly 2000 graphite targets have been produced from materials such as plant macrofossils, charcoal, peat, bones, shells and wood. The equipment comprises a station for chemical preparation and high vacuum lines for production, purification and graphitization of sample carbon dioxide. The present capacity allows preparation of up to 400 targets annually for the needs of scientific projects and external orders for radiocarbon dating continuously received by the GADAM Centre of Excellence. The laboratory's sample preparation protocols and recent improvements are described and its performance during the 10 years of activity is discussed in terms of parameters obtained from reference materials prepared in this laboratory and demonstrated with a few science applications.

  7. Sample preparation techniques of biological material for isotope analysis

    International Nuclear Information System (INIS)

    Axmann, H.; Sebastianelli, A.; Arrillaga, J.L.

    1990-01-01

    Sample preparation is an essential step in all isotope-aided experiments but often it is not given enough attention. The methods of sample preparation are very important to obtain reliable and precise analytical data and for further interpretation of results. The size of a sample required for chemical analysis is usually very small (10mg-1500mg). On the other hand the amount of harvested plant material from plots in a field experiment is often bulky (several kilograms) and the entire sample is too large for processing. In addition, while approaching maturity many crops show not only differences in physical consistency but also a non-uniformity in 15 N content among plant parts, requiring a plant fractionation or separation into parts (vegetative and reproductive) e.g. shoots and spikes, in case of small grain cereals, shoots and pods in case of grain legumes and tops and roots or beets (including crown) in case of sugar beet, etc. In any case the ultimate goal of these procedures is to obtain representative subsample harvested from greenhouse or field experiments for chemical analysis. Before harvesting an isotopic-aided experiment the method of sampling has to be selected. It should be based on the type of information required in relation to the objectives of the research and the availability of resources (staff, sample preparation equipment, analytical facilities, chemicals and supplies, etc.). 10 refs, 3 figs, 3 tabs

  8. [Progress in sample preparation and analytical methods for trace polar small molecules in complex samples].

    Science.gov (United States)

    Zhang, Qianchun; Luo, Xialin; Li, Gongke; Xiao, Xiaohua

    2015-09-01

    Small polar molecules such as nucleosides, amines, amino acids are important analytes in biological, food, environmental, and other fields. It is necessary to develop efficient sample preparation and sensitive analytical methods for rapid analysis of these polar small molecules in complex matrices. Some typical materials in sample preparation, including silica, polymer, carbon, boric acid and so on, are introduced in this paper. Meanwhile, the applications and developments of analytical methods of polar small molecules, such as reversed-phase liquid chromatography, hydrophilic interaction chromatography, etc., are also reviewed.

  9. Considerations for Sample Preparation Using Size-Exclusion Chromatography for Home and Synchrotron Sources.

    Science.gov (United States)

    Rambo, Robert P

    2017-01-01

    The success of a SAXS experiment for structural investigations depends on two precise measurements, the sample and the buffer background. Buffer matching between the sample and background can be achieved using dialysis methods but in biological SAXS of monodisperse systems, sample preparation is routinely being performed with size exclusion chromatography (SEC). SEC is the most reliable method for SAXS sample preparation as the method not only purifies the sample for SAXS but also almost guarantees ideal buffer matching. Here, I will highlight the use of SEC for SAXS sample preparation and demonstrate using example proteins that SEC purification does not always provide for ideal samples. Scrutiny of the SEC elution peak using quasi-elastic and multi-angle light scattering techniques can reveal hidden features (heterogeneity) of the sample that should be considered during SAXS data analysis. In some cases, sample heterogeneity can be controlled using a small molecule additive and I outline a simple additive screening method for sample preparation.

  10. A Method for Microalgae Proteomics Analysis Based on Modified Filter-Aided Sample Preparation.

    Science.gov (United States)

    Li, Song; Cao, Xupeng; Wang, Yan; Zhu, Zhen; Zhang, Haowei; Xue, Song; Tian, Jing

    2017-11-01

    With the fast development of microalgal biofuel researches, the proteomics studies of microalgae increased quickly. A filter-aided sample preparation (FASP) method is widely used proteomics sample preparation method since 2009. Here, a method of microalgae proteomics analysis based on modified filter-aided sample preparation (mFASP) was described to meet the characteristics of microalgae cells and eliminate the error caused by over-alkylation. Using Chlamydomonas reinhardtii as the model, the prepared sample was tested by standard LC-MS/MS and compared with the previous reports. The results showed mFASP is suitable for most of occasions of microalgae proteomics studies.

  11. Selecting Sample Preparation Workflows for Mass Spectrometry-Based Proteomic and Phosphoproteomic Analysis of Patient Samples with Acute Myeloid Leukemia

    Directory of Open Access Journals (Sweden)

    Maria Hernandez-Valladares

    2016-08-01

    Full Text Available Global mass spectrometry (MS-based proteomic and phosphoproteomic studies of acute myeloid leukemia (AML biomarkers represent a powerful strategy to identify and confirm proteins and their phosphorylated modifications that could be applied in diagnosis and prognosis, as a support for individual treatment regimens and selection of patients for bone marrow transplant. MS-based studies require optimal and reproducible workflows that allow a satisfactory coverage of the proteome and its modifications. Preparation of samples for global MS analysis is a crucial step and it usually requires method testing, tuning and optimization. Different proteomic workflows that have been used to prepare AML patient samples for global MS analysis usually include a standard protein in-solution digestion procedure with a urea-based lysis buffer. The enrichment of phosphopeptides from AML patient samples has previously been carried out either with immobilized metal affinity chromatography (IMAC or metal oxide affinity chromatography (MOAC. We have recently tested several methods of sample preparation for MS analysis of the AML proteome and phosphoproteome and introduced filter-aided sample preparation (FASP as a superior methodology for the sensitive and reproducible generation of peptides from patient samples. FASP-prepared peptides can be further fractionated or IMAC-enriched for proteome or phosphoproteome analyses. Herein, we will review both in-solution and FASP-based sample preparation workflows and encourage the use of the latter for the highest protein and phosphorylation coverage and reproducibility.

  12. Final Report for X-ray Diffraction Sample Preparation Method Development

    Energy Technology Data Exchange (ETDEWEB)

    Ely, T. M. [Hanford Site (HNF), Richland, WA (United States); Meznarich, H. K. [Hanford Site (HNF), Richland, WA (United States); Valero, T. [Hanford Site (HNF), Richland, WA (United States)

    2018-01-30

    WRPS-1500790, “X-ray Diffraction Saltcake Sample Preparation Method Development Plan/Procedure,” was originally prepared with the intent of improving the specimen preparation methodology used to generate saltcake specimens suitable for XRD-based solid phase characterization. At the time that this test plan document was originally developed, packed powder in cavity supports with collodion binder was the established XRD specimen preparation method. An alternate specimen preparation method less vulnerable, if not completely invulnerable to preferred orientation effects, was desired as a replacement for the method.

  13. Sample Preparation (SS): SE51_SS01 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available e Master NEO, BMS, Tokyo, Japan), and the seed powder was extracted with 1 mL of extraction buffer (0.1% HCO...trifugation (4 ℃, 10,000 rpm, 5 min), the sample tubes were subjected to sample preparation (buffer transfer

  14. Challenges in TEM sample preparation of solvothermally grown CuInS2 films.

    Science.gov (United States)

    Frank, Anna; Changizi, Rasa; Scheu, Christina

    2018-06-01

    Transmission electron microscopy (TEM) is a widely used tool to characterize materials. The required samples need to be electron transparent which should be achieved without changing the microstructure. This work describes different TEM sample preparation techniques of nanostructured CuInS 2 thin films on fluorine-doped tin oxide substrates, synthesized solvothermally using l-cysteine as sulfur source. Focused ion beam lamellae, conventional cross section samples and scratch samples have been prepared and investigated. It was possible to prepare appropriate samples with each technique, however, each technique brings with it certain advantages and disadvantages. FIB preparation of solvothermally synthesized CuInS 2 suffers from two main drawbacks. First, the whole CuInS 2 layer displays a strongly increased Cu content caused by Cu migration and preferential removal of In. Further, electron diffraction shows the formation of an additional CuS phase after Ga + bombardment. Second, diffraction analysis is complicated by a strong contribution of crystalline Pt introduced during the FIB preparation and penetrating into the porous film surface. The conventional cross sectional CuInS 2 sample also shows a Cu signal enhancement which is caused by contribution of the brass tube material used for embedding. Additionally, Cu particles have been observed inside the CuInS 2 which have been sputtered on the film during preparation. Only the scratch samples allow an almost artefact-free and reliable elemental quantification using energy-dispersive X-ray spectroscopy. However, scratch samples suffer from the drawback that it is not possible to determine the layer thickness, which is possible for both cross sectional preparation techniques. Consequently, it is concluded that the type of sample preparation should be chosen dependent on the required information. A full characterization can only be achieved when the different techniques are combined. Copyright © 2018 Elsevier Ltd. All

  15. Automated SEM and TEM sample preparation applied to copper/low k materials

    Science.gov (United States)

    Reyes, R.; Shaapur, F.; Griffiths, D.; Diebold, A. C.; Foran, B.; Raz, E.

    2001-01-01

    We describe the use of automated microcleaving for preparation of both SEM and TEM samples as done by SELA's new MC500 and TEMstation tools. The MC500 is an automated microcleaving tool that is capable of producing cleaves with 0.25 μm accuracy resulting in SEM-ready samples. The TEMstation is capable of taking a sample output from the MC500 (or from SELA's earlier MC200 tool) and producing a FIB ready slice of 25±5 μm, mounted on a TEM-washer and ready for FIB thinning to electron transparency for TEM analysis. The materials selected for the tool set evaluation mainly included the Cu/TaN/HOSP low-k system. The paper is divided into three sections, experimental approach, SEM preparation and analysis of HOSP low-k, and TEM preparation and analysis of Cu/TaN/HOSP low-k samples. For the samples discussed, data is presented to show the quality of preparation provided by these new automated tools.

  16. Polymeric ionic liquid-based portable tip microextraction device for on-site sample preparation of water samples.

    Science.gov (United States)

    Chen, Lei; Pei, Junxian; Huang, Xiaojia; Lu, Min

    2018-06-05

    On-site sample preparation is highly desired because it avoids the transportation of large-volume samples and ensures the accuracy of the analytical results. In this work, a portable prototype of tip microextraction device (TMD) was designed and developed for on-site sample pretreatment. The assembly procedure of TMD is quite simple. Firstly, polymeric ionic liquid (PIL)-based adsorbent was in-situ prepared in a pipette tip. After that, the tip was connected with a syringe which was driven by a bidirectional motor. The flow rates in adsorption and desorption steps were controlled accurately by the motor. To evaluate the practicability of the developed device, the TMD was used to on-site sample preparation of waters and combined with high-performance liquid chromatography with diode array detection to measure trace estrogens in water samples. Under the most favorable conditions, the limits of detection (LODs, S/N = 3) for the target analytes were in the range of 4.9-22 ng/L, with good coefficients of determination. Confirmatory study well evidences that the extraction performance of TMD is comparable to that of the traditional laboratory solid-phase extraction process, but the proposed TMD is more simple and convenient. At the same time, the TMD avoids complicated sampling and transferring steps of large-volume water samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Magnetic separation techniques in sample preparation for biological analysis: a review.

    Science.gov (United States)

    He, Jincan; Huang, Meiying; Wang, Dongmei; Zhang, Zhuomin; Li, Gongke

    2014-12-01

    Sample preparation is a fundamental and essential step in almost all the analytical procedures, especially for the analysis of complex samples like biological and environmental samples. In past decades, with advantages of superparamagnetic property, good biocompatibility and high binding capacity, functionalized magnetic materials have been widely applied in various processes of sample preparation for biological analysis. In this paper, the recent advancements of magnetic separation techniques based on magnetic materials in the field of sample preparation for biological analysis were reviewed. The strategy of magnetic separation techniques was summarized. The synthesis, stabilization and bio-functionalization of magnetic nanoparticles were reviewed in detail. Characterization of magnetic materials was also summarized. Moreover, the applications of magnetic separation techniques for the enrichment of protein, nucleic acid, cell, bioactive compound and immobilization of enzyme were described. Finally, the existed problems and possible trends of magnetic separation techniques for biological analysis in the future were proposed. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. State of the art in sample preparation for trace element analysis (M1)

    International Nuclear Information System (INIS)

    Barnes, R.M.

    2002-01-01

    Full text: The accelerated capabilities of modern trace element analysis techniques, especially inductively coupled plasma mass spectrometry (ICP-MS), have challenged the sample preparation competence of most laboratories. Exceptional analytical sensitivity, remarkable analysis speed, automated sample presentation, and intelligent sample sequencing of modern spectroscopic instrumentation have lead to demanding requirements for appropriate sample preparation steps needed for ultra trace concentration and speciation measurements. Contamination control, reliable digestion and extraction techniques, presentation of chemical forms, sample matrix management, and intelligent sample processing available today are often inadequate for the most demanding measurements. Some commercial instrumentation provides convenient implementation of well-established contamination control measures, and reagent and container purity are steadily being improved. Direct sample introduction approaches offer alternatives to conventional solution samples, but achieving calibration reliability is difficult. Developing new sample preparation chemistry is especially arduous and rare, yet progress exists in characterizing microwave-assisted reactions. This presentation will describe contemporary targets for modern sample preparation approaches for ultra trace elemental analysis and the likelihood that they can be reasonably achieved. (author)

  19. The effect of sample preparation methods on glass performance

    International Nuclear Information System (INIS)

    Oh, M.S.; Oversby, V.M.

    1990-01-01

    A series of experiments was conducted using SRL 165 synthetic waste glass to investigate the effects of surface preparation and leaching solution composition on the alteration of the glass. Samples of glass with as-cast surfaces produced smooth reaction layers and some evidence for precipitation of secondary phases from solution. Secondary phases were more abundant in samples reacted in deionized water than for those reacted in a silicate solution. Samples with saw-cut surfaces showed a large reduction in surface roughness after 7 days of reaction in either solution. Reaction in silicate solution for up to 91 days produced no further change in surface morphology, while reaction in DIW produced a spongy surface that formed the substrate for further surface layer development. The differences in the surface morphology of the samples may create microclimates that control the details of development of alteration layers on the glass; however, the concentrations of elements in leaching solutions show differences of 50% or less between samples prepared with different surface conditions for tests of a few months duration. 6 refs., 7 figs., 1 tab

  20. Preparation of Cytology Samples: Tricks of the Trade.

    Science.gov (United States)

    Moore, A Russell

    2017-01-01

    General principles and techniques for collection, preparation, and staining of cytologic samples in the general practice setting are reviewed. Tips for collection of digital images are also discussed. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Sample preparation procedures utilized in microbial metabolomics: An overview.

    Science.gov (United States)

    Patejko, Małgorzata; Jacyna, Julia; Markuszewski, Michał J

    2017-02-01

    Bacteria are remarkably diverse in terms of their size, structure and biochemical properties. Due to this fact, it is hard to develop a universal method for handling bacteria cultures during metabolomic analysis. The choice of suitable processing methods constitutes a key element in any analysis, because only appropriate selection of procedures may provide accurate results, leading to reliable conclusions. Because of that, every analytical experiment concerning bacteria requires individually and very carefully planned research methodology. Although every study varies in terms of sample preparation, there are few general steps to follow while planning experiment, like sampling, separation of cells from growth medium, stopping their metabolism and extraction. As a result of extraction, all intracellular metabolites should be washed out from cell environment. What is more, extraction method utilized cannot cause any chemical decomposition or degradation of the metabolome. Furthermore, chosen extraction method should correlate with analytical technique, so it will not disturb or prolong following sample preparation steps. For those reasons, we observe a need to summarize sample preparation procedures currently utilized in microbial metabolomic studies. In the presented overview, papers concerning analysis of extra- and intracellular metabolites, published over the last decade, have been discussed. Presented work gives some basic guidelines that might be useful while planning experiments in microbial metabolomics. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Sample preparation techniques for (p, X) spectrometry

    International Nuclear Information System (INIS)

    Whitehead, N.E.

    1985-01-01

    Samples are ashed at low temperature, using oxygen plasma; a rotary evaporator, and freeze drying speeded up the ashing. The new design of apparatus manufactured was only 10 watt but was as efficient as a 200 watt commercial machine; a circuit diagram is included. Samples of hair and biopsy samples of skin were analysed by the technique. A wool standard was prepared for interlaboratory comparison exercises. It was based on New Zealand merino sheep wool and was 2.9 kg in weight. A washing protocol was developed, which preserves most of the trace element content. The wool was ground in liquid nitrogen using a plastic pestle and beaker, driven by a rotary drill press. (author)

  3. Traceability and measurement uncertainty in sample preparation (W5)

    International Nuclear Information System (INIS)

    Wegscheider, W.; Walner, U.; Moser, J.

    2002-01-01

    Full text: Very few chemical measurements are being made directly on the object of interest and sample preparation is thus the rule rather than the exception in daily practice. Unfortunately the operations undertaken in the course of sample preparation are prone to rendering a sample useless for the purpose of interpreting a measurement performed on it, as it might not represent the original and relevant status any longer. Sample preparation along with sampling itself constitutes therefore a procedure that leads to a loss of representation of the original specimen or population. On the other hand it is also not sufficient to confine aspects of traceability and measurement uncertainty to the ultimate measurement, as the key purpose of measuring is to supply adequate data for some kind of decision, be it in production, in health, in the environment, or indeed in any other circumstance. These considerations have led to severe confusion in the community as to what traceability really means in chemistry. CITAC and EURACHEM have only recently issued a preliminary document that clarifies these issues and gives a firm handle on the future development of quality assurance in analytical chemistry. In this talk it will be attempted to outline the general ideas and procedures that lead to traceability of analytical chemical results accompanied by valid statements of their uncertainty. It will be argued that the central element in achieving these goals is a well-designed validation study that frequently goes beyond those requirements currently laid out in official documents. (author)

  4. Mechanical Conversion for High-Throughput TEM Sample Preparation

    International Nuclear Information System (INIS)

    Kendrick, Anthony B; Moore, Thomas M; Zaykova-Feldman, Lyudmila

    2006-01-01

    This paper presents a novel method of direct mechanical conversion from lift-out sample to TEM sample holder. The lift-out sample is prepared in the FIB using the in-situ liftout Total Release TM method. The mechanical conversion is conducted using a mechanical press and one of a variety of TEM coupons, including coupons for both top-side and back-side thinning. The press joins a probe tip point with attached TEM sample to the sample coupon and separates the complete assembly as a 3mm diameter TEM grid, compatible with commercially available TEM sample holder rods. This mechanical conversion process lends itself well to the high through-put requirements of in-line process control and to materials characterization labs where instrument utilization and sample security are critically important

  5. 40 CFR 205.171-2 - Test exhaust system sample selection and preparation.

    Science.gov (United States)

    2010-07-01

    ... Systems § 205.171-2 Test exhaust system sample selection and preparation. (a)(1) Exhaust systems... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Test exhaust system sample selection and preparation. 205.171-2 Section 205.171-2 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...

  6. Droplet Size-Aware and Error-Correcting Sample Preparation Using Micro-Electrode-Dot-Array Digital Microfluidic Biochips.

    Science.gov (United States)

    Li, Zipeng; Lai, Kelvin Yi-Tse; Chakrabarty, Krishnendu; Ho, Tsung-Yi; Lee, Chen-Yi

    2017-12-01

    Sample preparation in digital microfluidics refers to the generation of droplets with target concentrations for on-chip biochemical applications. In recent years, digital microfluidic biochips (DMFBs) have been adopted as a platform for sample preparation. However, there remain two major problems associated with sample preparation on a conventional DMFB. First, only a (1:1) mixing/splitting model can be used, leading to an increase in the number of fluidic operations required for sample preparation. Second, only a limited number of sensors can be integrated on a conventional DMFB; as a result, the latency for error detection during sample preparation is significant. To overcome these drawbacks, we adopt a next generation DMFB platform, referred to as micro-electrode-dot-array (MEDA), for sample preparation. We propose the first sample-preparation method that exploits the MEDA-specific advantages of fine-grained control of droplet sizes and real-time droplet sensing. Experimental demonstration using a fabricated MEDA biochip and simulation results highlight the effectiveness of the proposed sample-preparation method.

  7. Error Analysis of Ceramographic Sample Preparation for Coating Thickness Measurement of Coated Fuel Particles

    International Nuclear Information System (INIS)

    Liu Xiaoxue; Li Ziqiang; Zhao Hongsheng; Zhang Kaihong; Tang Chunhe

    2014-01-01

    The thicknesses of four coatings of HTR coated fuel particle are very important parameters. It is indispensable to control the thickness of four coatings of coated fuel particles for the safety of HTR. A measurement method, ceramographic sample-microanalysis method, to analyze the thickness of coatings was developed. During the process of ceramographic sample-microanalysis, there are two main errors, including ceramographic sample preparation error and thickness measurement error. With the development of microscopic techniques, thickness measurement error can be easily controlled to meet the design requirements. While, due to the coated particles are spherical particles of different diameters ranged from 850 to 1000μm, the sample preparation process will introduce an error. And this error is different from one sample to another. It’s also different from one particle to another in the same sample. In this article, the error of the ceramographic sample preparation was calculated and analyzed. Results show that the error introduced by sample preparation is minor. The minor error of sample preparation guarantees the high accuracy of the mentioned method, which indicates this method is a proper method to measure the thickness of four coatings of coated particles. (author)

  8. Miniaturizing EM Sample Preparation: Opportunities, Challenges, and "Visual Proteomics".

    Science.gov (United States)

    Arnold, Stefan A; Müller, Shirley A; Schmidli, Claudio; Syntychaki, Anastasia; Rima, Luca; Chami, Mohamed; Stahlberg, Henning; Goldie, Kenneth N; Braun, Thomas

    2018-03-01

    This review compares and discusses conventional versus miniaturized specimen preparation methods for transmission electron microscopy (TEM). The progress brought by direct electron detector cameras, software developments and automation have transformed transmission cryo-electron microscopy (cryo-EM) and made it an invaluable high-resolution structural analysis tool. In contrast, EM specimen preparation has seen very little progress in the last decades and is now one of the main bottlenecks in cryo-EM. Here, we discuss the challenges faced by specimen preparation for single particle EM, highlight current developments, and show the opportunities resulting from the advanced miniaturized and microfluidic sample grid preparation methods described, such as visual proteomics and time-resolved cryo-EM studies. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Optimized preparation of urine samples for two-dimensional electrophoresis and initial application to patient samples

    DEFF Research Database (Denmark)

    Lafitte, Daniel; Dussol, Bertrand; Andersen, Søren

    2002-01-01

    OBJECTIVE: We optimized of the preparation of urinary samples to obtain a comprehensive map of urinary proteins of healthy subjects and then compared this map with the ones obtained with patient samples to show that the pattern was specific of their kidney disease. DESIGN AND METHODS: The urinary...

  10. Analytical characterization of high-level mixed wastes using multiple sample preparation treatments

    International Nuclear Information System (INIS)

    King, A.G.; Baldwin, D.L.; Urie, M.W.; McKinley, S.G.

    1994-01-01

    The Analytical Chemistry Laboratory at the Pacific Northwest Laboratory in Richland, Washington, is actively involved in performing analytical characterization of high-level mixed waste from Hanford's single shell and double shell tank characterization programs. A full suite of analyses is typically performed on homogenized tank core samples. These analytical techniques include inductively-coupled plasma-atomic emission spectroscopy, total organic carbon methods and radiochemistry methods, as well as many others, all requiring some type of remote sample-preparation treatment to solubilize the tank sludge material for analysis. Most of these analytical methods typically use a single sample-preparation treatment, inherently providing elemental information only. To better understand and interpret tank chemistry and assist in identifying chemical compounds, selected analytical methods are performed using multiple sample-preparation treatments. The sample preparation treatments used at Pacific Northwest Laboratory for this work with high-level mixed waste include caustic fusion, acid digestion, and water leach. The type of information available by comparing results from different sample-prep treatments includes evidence for the presence of refractory compounds, acid-soluble compounds, or water-soluble compounds. Problems unique to the analysis of Hanford tank wastes are discussed. Selected results from the Hanford single shell ferrocyanide tank, 241-C-109, are presented, and the resulting conclusions are discussed

  11. Novel sample preparation for operando TEM of catalysts

    International Nuclear Information System (INIS)

    Miller, Benjamin K.; Barker, Trevor M.; Crozier, Peter A.

    2015-01-01

    A new TEM sample preparation method is developed to facilitate operando TEM of gas phase catalysis. A porous Pyrex-fiber pellet TEM sample was produced, allowing a comparatively large amount of catalyst to be loaded into a standard Gatan furnace-type tantalum heating holder. The increased amount of catalyst present inside the environmental TEM allows quantitative determination of the gas phase products of a catalytic reaction performed in-situ at elevated temperatures. The product gas concentration was monitored using both electron energy loss spectroscopy (EELS) and residual gas analysis (RGA). Imaging of catalyst particles dispersed over the pellet at atomic resolution is challenging, due to charging of the insulating glass fibers. To overcome this limitation, a metal grid is placed into the holder in addition to the pellet, allowing catalyst particles dispersed over the grid to be imaged, while particles in the pellet, which are assumed to experience identical conditions, contribute to the overall catalytic conversion inside the environmental TEM cell. The gas within the cell is determined to be well-mixed, making this assumption reasonable. - Highlights: • High in-situ conversion of CO to CO 2 achieved by a novel TEM sample preparation method. • A 3 mm fiber pellet increases the TEM sample surface area by 50×. • Operando atomic resolution is maintained by also including a 3 mm grid in the sample. • Evidence for a well-mixed gas composition inside the ETEM cell is given

  12. Sample Preparation Strategies for the Effective Quantitation of Hydrophilic Metabolites in Serum by Multi-Targeted HILIC-MS/MS

    Directory of Open Access Journals (Sweden)

    Elisavet Tsakelidou

    2017-03-01

    Full Text Available The effect of endogenous interferences of serum in multi-targeted metabolite profiling HILIC-MS/MS analysis was investigated by studying different sample preparation procedures. A modified QuEChERS dispersive SPE protocol, a HybridSPE protocol, and a combination of liquid extraction with protein precipitation were compared to a simple protein precipitation. Evaluation of extraction efficiency and sample clean-up was performed for all methods. SPE sorbent materials tested were found to retain hydrophilic analytes together with endogenous interferences, thus additional elution steps were needed. Liquid extraction was not shown to minimise matrix effects. In general, it was observed that a balance should be reached in terms of recovery, efficient clean-up, and sample treatment time when a wide range of metabolites are analysed. A quick step for removing phospholipids prior to the determination of hydrophilic endogenous metabolites is required, however, based on the results from the applied methods, further studies are needed to achieve high recoveries for all metabolites.

  13. Collection and preparation of wet and dry stream-sediment samples

    International Nuclear Information System (INIS)

    Puchlik, K.

    1977-03-01

    Lawrence Livermore Laboratory is responsible for the Hydrogeochemistry and Stream Sediment Reconnaissance (HSSR) program for uranium in the seven far western states. The work thus far has concentrated on the arid to semi-arid regions of the West and this paper discusses the collection and preparation of sediment samples in the Basin and Range province. The sample collection and preparation procedures described here may not be applicable to other parts of the far western states or other areas. These procedures also differ somewhat from those used by the other three laboratories involved in the HSSR program

  14. Sampling and sample preparation methods for the analysis of trace elements in biological material

    International Nuclear Information System (INIS)

    Sansoni, B.; Iyengar, V.

    1978-05-01

    The authors attempt to give a most systamtic possible treatment of the sample taking and sample preparation of biological material (particularly in human medicine) for trace analysis (e.g. neutron activation analysis, atomic absorption spectrometry). Contamination and loss problems are discussed as well as the manifold problems of the different consistency of solid and liquid biological materials, as well as the stabilization of the sample material. The process of dry and wet ashing is particularly dealt with, where new methods are also described. (RB) [de

  15. Sample preparation with solid phase microextraction and exhaustive extraction approaches: Comparison for challenging cases.

    Science.gov (United States)

    Boyacı, Ezel; Rodríguez-Lafuente, Ángel; Gorynski, Krzysztof; Mirnaghi, Fatemeh; Souza-Silva, Érica A; Hein, Dietmar; Pawliszyn, Janusz

    2015-05-11

    In chemical analysis, sample preparation is frequently considered the bottleneck of the entire analytical method. The success of the final method strongly depends on understanding the entire process of analysis of a particular type of analyte in a sample, namely: the physicochemical properties of the analytes (solubility, volatility, polarity etc.), the environmental conditions, and the matrix components of the sample. Various sample preparation strategies have been developed based on exhaustive or non-exhaustive extraction of analytes from matrices. Undoubtedly, amongst all sample preparation approaches, liquid extraction, including liquid-liquid (LLE) and solid phase extraction (SPE), are the most well-known, widely used, and commonly accepted methods by many international organizations and accredited laboratories. Both methods are well documented and there are many well defined procedures, which make them, at first sight, the methods of choice. However, many challenging tasks, such as complex matrix applications, on-site and in vivo applications, and determination of matrix-bound and free concentrations of analytes, are not easily attainable with these classical approaches for sample preparation. In the last two decades, the introduction of solid phase microextraction (SPME) has brought significant progress in the sample preparation area by facilitating on-site and in vivo applications, time weighted average (TWA) and instantaneous concentration determinations. Recently introduced matrix compatible coatings for SPME facilitate direct extraction from complex matrices and fill the gap in direct sampling from challenging matrices. Following introduction of SPME, numerous other microextraction approaches evolved to address limitations of the above mentioned techniques. There is not a single method that can be considered as a universal solution for sample preparation. This review aims to show the main advantages and limitations of the above mentioned sample

  16. Automated dried blood spots standard and QC sample preparation using a robotic liquid handler.

    Science.gov (United States)

    Yuan, Long; Zhang, Duxi; Aubry, Anne-Francoise; Arnold, Mark E

    2012-12-01

    A dried blood spot (DBS) bioanalysis assay involves many steps, such as the preparation of standard (STD) and QC samples in blood, the spotting onto DBS cards, and the cutting-out of the spots. These steps are labor intensive and time consuming if done manually, which, therefore, makes automation very desirable in DBS bioanalysis. A robotic liquid handler was successfully applied to the preparation of STD and QC samples in blood and to spot the blood samples onto DBS cards using buspirone as the model compound. This automated preparation was demonstrated to be accurate and consistent. However the accuracy and precision of automated preparation were similar to those from manual preparation. The effect of spotting volume on accuracy was evaluated and a trend of increasing concentrations of buspirone with increasing spotting volumes was observed. The automated STD and QC sample preparation process significantly improved the efficiency, robustness and safety of DBS bioanalysis.

  17. Green sample preparation for liquid chromatography and capillary electrophoresis of anionic and cationic analytes.

    Science.gov (United States)

    Wuethrich, Alain; Haddad, Paul R; Quirino, Joselito P

    2015-04-21

    A sample preparation device for the simultaneous enrichment and separation of cationic and anionic analytes was designed and implemented in an eight-channel configuration. The device is based on the use of an electric field to transfer the analytes from a large volume of sample into small volumes of electrolyte that was suspended into two glass micropipettes using a conductive hydrogel. This simple, economical, fast, and green (no organic solvent required) sample preparation scheme was evaluated using cationic and anionic herbicides as test analytes in water. The analytical figures of merit and ecological aspects were evaluated against the state-of-the-art sample preparation, solid-phase extraction. A drastic reduction in both sample preparation time (94% faster) and resources (99% less consumables used) was observed. Finally, the technique in combination with high-performance liquid chromatography and capillary electrophoresis was applied to analysis of quaternary ammonium and phenoxypropionic acid herbicides in fortified river water as well as drinking water (at levels relevant to Australian guidelines). The presented sustainable sample preparation approach could easily be applied to other charged analytes or adopted by other laboratories.

  18. Independent assessment of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) sample preparation quality : Effect of sample preparation on MALDI-MS of synthetic polymers

    NARCIS (Netherlands)

    Kooijman, Pieter C.; Kok, Sander; Honing, Maarten

    2017-01-01

    Rationale: Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) provides detailed and in-depth information about the molecular characteristics of synthetic polymers. To obtain the most accurate results the sample preparation parameters should be chosen to suit the sample and the

  19. Sample Preparation of Corn Seed Tissue to Prevent Analyte Relocations for Mass Spectrometry Imaging

    Science.gov (United States)

    Kim, Shin Hye; Kim, Jeongkwon; Lee, Young Jin; Lee, Tae Geol; Yoon, Sohee

    2017-08-01

    Corn seed tissue sections were prepared by the tape support method using an adhesive tape, and mass spectrometry imaging (MSI) was performed. The effect of heat generated during sample preparation was investigated by time-of-flight secondary mass spectrometry (TOF-SIMS) imaging of corn seed tissue prepared by the tape support and the thaw-mounted methods. Unlike thaw-mounted sample preparation, the tape support method does not cause imaging distortion because of the absence of heat, which can cause migration of the analytes on the sample. By applying the tape-support method, the corn seed tissue was prepared without structural damage and MSI with accurate spatial information of analytes was successfully performed.

  20. Sample Preparation of Corn Seed Tissue to Prevent Analyte Relocations for Mass Spectrometry Imaging.

    Science.gov (United States)

    Kim, Shin Hye; Kim, Jeongkwon; Lee, Young Jin; Lee, Tae Geol; Yoon, Sohee

    2017-08-01

    Corn seed tissue sections were prepared by the tape support method using an adhesive tape, and mass spectrometry imaging (MSI) was performed. The effect of heat generated during sample preparation was investigated by time-of-flight secondary mass spectrometry (TOF-SIMS) imaging of corn seed tissue prepared by the tape support and the thaw-mounted methods. Unlike thaw-mounted sample preparation, the tape support method does not cause imaging distortion because of the absence of heat, which can cause migration of the analytes on the sample. By applying the tape-support method, the corn seed tissue was prepared without structural damage and MSI with accurate spatial information of analytes was successfully performed. Graphical Abstract ᅟ.

  1. Universal Sample Preparation Module for Molecular Analysis in Space, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Lynntech proposes to develop and demonstrate the ability of a compact, light-weight, and automated universal sample preparation module (USPM) to process samples from...

  2. Tank 12H residuals sample analysis report

    Energy Technology Data Exchange (ETDEWEB)

    Oji, L. N. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Shine, E. P. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Diprete, D. P. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Coleman, C. J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hay, M. S. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-06-11

    The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) to provide sample preparation and analysis of the Tank 12H final characterization samples to determine the residual tank inventory prior to grouting. Eleven Tank 12H floor and mound residual material samples and three cooling coil scrape samples were collected and delivered to SRNL between May and August of 2014.

  3. Recent developments in sample preparation and data pre-treatment in metabonomics research.

    Science.gov (United States)

    Li, Ning; Song, Yi peng; Tang, Huiru; Wang, Yulan

    2016-01-01

    Metabonomics is a powerful approach for biomarker discovery and an effective tool for pinpointing endpoint metabolic effects of external stimuli, such as pathogens and disease development. Due to its wide applications, metabonomics is required to deal with various biological samples of different properties. Hence sample preparation and corresponding data pre-treatment become important factors in ensuring validity of an investigation. In this review, we summarize some recent developments in metabonomics sample preparation and data-pretreatment procedures. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Current advances and strategies towards fully automated sample preparation for regulated LC-MS/MS bioanalysis.

    Science.gov (United States)

    Zheng, Naiyu; Jiang, Hao; Zeng, Jianing

    2014-09-01

    Robotic liquid handlers (RLHs) have been widely used in automated sample preparation for liquid chromatography-tandem mass spectrometry (LC-MS/MS) bioanalysis. Automated sample preparation for regulated bioanalysis offers significantly higher assay efficiency, better data quality and potential bioanalytical cost-savings. For RLHs that are used for regulated bioanalysis, there are additional requirements, including 21 CFR Part 11 compliance, software validation, system qualification, calibration verification and proper maintenance. This article reviews recent advances in automated sample preparation for regulated bioanalysis in the last 5 years. Specifically, it covers the following aspects: regulated bioanalysis requirements, recent advances in automation hardware and software development, sample extraction workflow simplification, strategies towards fully automated sample extraction, and best practices in automated sample preparation for regulated bioanalysis.

  5. Synthesis and application of magnetic molecularly imprinted polymers in sample preparation.

    Science.gov (United States)

    Huang, Shuyao; Xu, Jianqiao; Zheng, Jiating; Zhu, Fang; Xie, Lijun; Ouyang, Gangfeng

    2018-04-12

    Magnetic molecularly imprinted polymers (MMIPs) have superior advantages in sample pretreatment because of their high selectivity for target analytes and the fast and easy isolation from samples. To meet the demand of both good magnetic property and good extraction performance, MMIPs with various structures, from traditional core-shell structures to novel composite structures with a larger specific surface area and more accessible binding sites, are fabricated by different preparation technologies. Moreover, as the molecularly imprinted polymer (MIP) layers determine the affinity, selectivity, and saturated adsorption amount of MMIPs, the development and innovation of the MIP layer are attracting attention and are reviewed here. Many studies that used MMIPs as sorbents in dispersive solid-phase extraction of complex samples, including environmental, food, and biofluid samples, are summarized. Graphical abstract The application of magnetic molecularly imprinted polymers (MIPs) in the sample preparation procedure improves the analytical performances for complex samples. MITs molecular imprinting technologies.

  6. Sample preparation and detection device for infectious agents

    Science.gov (United States)

    Miles, Robin R.; Wang, Amy W.; Fuller, Christopher K.; Lemoff, Asuncion V.; Bettencourt, Kerry A.; Yu, June

    2003-06-10

    A sample preparation and analysis device which incorporates both immunoassays and PCR assays in one compact, field-portable microchip. The device provides new capabilities in fluid and particle control which allows the building of a fluidic chip with no moving parts, thus decreasing fabrication cost and increasing the robustness of the device. The device can operate in a true continuous (not batch) mode. The device incorporates magnetohydrodynamic (MHD) pumps to move the fluid through the system, acoustic mixing and fractionation, dielectropheretic (DEP) sample concentration and purification, and on-chip optical detection capabilities.

  7. Fast Markov chain Monte Carlo sampling for sparse Bayesian inference in high-dimensional inverse problems using L1-type priors

    International Nuclear Information System (INIS)

    Lucka, Felix

    2012-01-01

    Sparsity has become a key concept for solving of high-dimensional inverse problems using variational regularization techniques. Recently, using similar sparsity-constraints in the Bayesian framework for inverse problems by encoding them in the prior distribution has attracted attention. Important questions about the relation between regularization theory and Bayesian inference still need to be addressed when using sparsity promoting inversion. A practical obstacle for these examinations is the lack of fast posterior sampling algorithms for sparse, high-dimensional Bayesian inversion. Accessing the full range of Bayesian inference methods requires being able to draw samples from the posterior probability distribution in a fast and efficient way. This is usually done using Markov chain Monte Carlo (MCMC) sampling algorithms. In this paper, we develop and examine a new implementation of a single component Gibbs MCMC sampler for sparse priors relying on L1-norms. We demonstrate that the efficiency of our Gibbs sampler increases when the level of sparsity or the dimension of the unknowns is increased. This property is contrary to the properties of the most commonly applied Metropolis–Hastings (MH) sampling schemes. We demonstrate that the efficiency of MH schemes for L1-type priors dramatically decreases when the level of sparsity or the dimension of the unknowns is increased. Practically, Bayesian inversion for L1-type priors using MH samplers is not feasible at all. As this is commonly believed to be an intrinsic feature of MCMC sampling, the performance of our Gibbs sampler also challenges common beliefs about the applicability of sample based Bayesian inference. (paper)

  8. Characterization of the Bacterial Community Naturally Present on Commercially Grown Basil Leaves: Evaluation of Sample Preparation Prior to Culture-Independent Techniques

    Directory of Open Access Journals (Sweden)

    Siele Ceuppens

    2015-08-01

    Full Text Available Fresh herbs such as basil constitute an important food commodity worldwide. Basil provides considerable culinary and health benefits, but has also been implicated in foodborne illnesses. The naturally occurring bacterial community on basil leaves is currently unknown, so the epiphytic bacterial community was investigated using the culture-independent techniques denaturing gradient gel electrophoresis (DGGE and next-generation sequencing (NGS. Sample preparation had a major influence on the results from DGGE and NGS: Novosphingobium was the dominant genus for three different basil batches obtained by maceration of basil leaves, while washing of the leaves yielded lower numbers but more variable dominant bacterial genera including Klebsiella, Pantoea, Flavobacterium, Sphingobacterium and Pseudomonas. During storage of basil, bacterial growth and shifts in the bacterial community were observed with DGGE and NGS. Spoilage was not associated with specific bacterial groups and presumably caused by physiological tissue deterioration and visual defects, rather than by bacterial growth.

  9. Preparing learners with partly incorrect intuitive prior knowledge for learning

    Directory of Open Access Journals (Sweden)

    Andrea eOhst

    2014-07-01

    Full Text Available Learners sometimes have incoherent and fragmented intuitive prior knowledge that is (partly ‘incompatible’ with the to-be-learned contents. Such knowledge in pieces can cause conceptual disorientation and cognitive overload while learning. We hypothesized that a pre-training intervention providing a generalized schema as a structuring framework for such knowledge in pieces would support (reorganizing-processes of prior knowledge and thus reduce unnecessary cognitive load during subsequent learning. Fifty-six student teachers participated in the experiment. A framework group underwent a pre-training intervention providing a generalized, categorical schema for categorizing primary learning strategies and related but different strategies as a cognitive framework for (re-organizing their prior knowledge. Our control group received comparable factual information but no framework. Afterwards, all participants learned about primary learning strategies. The framework group claimed to possess higher levels of interest and self-efficacy, achieved higher learning outcomes, and learned more efficiently. Hence, providing a categorical framework can help overcome the barrier of incorrect prior knowledge in pieces.

  10. Preparing learners with partly incorrect intuitive prior knowledge for learning

    Science.gov (United States)

    Ohst, Andrea; Fondu, Béatrice M. E.; Glogger, Inga; Nückles, Matthias; Renkl, Alexander

    2014-01-01

    Learners sometimes have incoherent and fragmented intuitive prior knowledge that is (partly) “incompatible” with the to-be-learned contents. Such knowledge in pieces can cause conceptual disorientation and cognitive overload while learning. We hypothesized that a pre-training intervention providing a generalized schema as a structuring framework for such knowledge in pieces would support (re)organizing-processes of prior knowledge and thus reduce unnecessary cognitive load during subsequent learning. Fifty-six student teachers participated in the experiment. A framework group underwent a pre-training intervention providing a generalized, categorical schema for categorizing primary learning strategies and related but different strategies as a cognitive framework for (re-)organizing their prior knowledge. Our control group received comparable factual information but no framework. Afterwards, all participants learned about primary learning strategies. The framework group claimed to possess higher levels of interest and self-efficacy, achieved higher learning outcomes, and learned more efficiently. Hence, providing a categorical framework can help overcome the barrier of incorrect prior knowledge in pieces. PMID:25071638

  11. High-resolution X-ray diffraction with no sample preparation.

    Science.gov (United States)

    Hansford, G M; Turner, S M R; Degryse, P; Shortland, A J

    2017-07-01

    It is shown that energy-dispersive X-ray diffraction (EDXRD) implemented in a back-reflection geometry is extremely insensitive to sample morphology and positioning even in a high-resolution configuration. This technique allows high-quality X-ray diffraction analysis of samples that have not been prepared and is therefore completely non-destructive. The experimental technique was implemented on beamline B18 at the Diamond Light Source synchrotron in Oxfordshire, UK. The majority of the experiments in this study were performed with pre-characterized geological materials in order to elucidate the characteristics of this novel technique and to develop the analysis methods. Results are presented that demonstrate phase identification, the derivation of precise unit-cell parameters and extraction of microstructural information on unprepared rock samples and other sample types. A particular highlight was the identification of a specific polytype of a muscovite in an unprepared mica schist sample, avoiding the time-consuming and difficult preparation steps normally required to make this type of identification. The technique was also demonstrated in application to a small number of fossil and archaeological samples. Back-reflection EDXRD implemented in a high-resolution configuration shows great potential in the crystallographic analysis of cultural heritage artefacts for the purposes of scientific research such as provenancing, as well as contributing to the formulation of conservation strategies. Possibilities for moving the technique from the synchrotron into museums are discussed. The avoidance of the need to extract samples from high-value and rare objects is a highly significant advantage, applicable also in other potential research areas such as palaeontology, and the study of meteorites and planetary materials brought to Earth by sample-return missions.

  12. Application of immunoaffinity columns for different food item samples preparation in micotoxins determination

    Directory of Open Access Journals (Sweden)

    Ćurčić Marijana

    2016-01-01

    Full Text Available In analytical methods used for monitoring of what special attention is paid to sample preparation. Therefore, the objective of this study was testing the efficiency of immunoaffinity columns (IAC that are based on solid phase extraction principles used for samples preparation in determining aflatoxins and ochratoxins. Aflatoxins and ochratoxins concentrations were determined in totally 56 samples of food items: wheat, corn, rice, barley and other grains (19 samples, flour and flour products from grain and additives for the bakery industry (7 samples, fruits and vegetables (3 samples, hazelnut, walnut, almond, coconut flour (4 samples, roasted cocoa beans, peanuts, tea, coffee (16 samples, spices (4 samples and meat and meat products (4 samples. Obtained results indicate advantage of IAC use for sample preparation based on enhanced specificity due to binding of extracted molecules to incorporated specific antibodies and rinsing the rest molecules from sample which could interfere with further analysis. Additional advantage is the usage of small amount of organic solvents and consequently decreased exposure of staff who conduct micotoxins determination. Of special interest is increase in method sensitivity since limit of quantification for aflatoxins and ochratoxins determination method is lower than maximal allowed concentration of these toxines prescribed by national rule book.

  13. HASE - The Helsinki adaptive sample preparation line

    Energy Technology Data Exchange (ETDEWEB)

    Palonen, V., E-mail: vesa.palonen@helsinki.fi [Department of Physics, University of Helsinki, P.O. Box 43, FI-00014 (Finland); Pesonen, A. [Laboratory of Chronology, Finnish Museum of Natural History, P.O. Box 64, FI-00014 (Finland); Herranen, T.; Tikkanen, P. [Department of Physics, University of Helsinki, P.O. Box 43, FI-00014 (Finland); Oinonen, M. [Laboratory of Chronology, Finnish Museum of Natural History, P.O. Box 64, FI-00014 (Finland)

    2013-01-15

    We have designed and built an adaptive sample preparation line with separate modules for combustion, molecular sieve handling, CO{sub 2} gas cleaning, CO{sub 2} storage, and graphitization. The line is also connected to an elemental analyzer. Operation of the vacuum equipment, a flow controller, pressure sensors, ovens, and graphitization reactors are automated with a reliable NI-cRIO real-time system. Stepped combustion can be performed in two ovens at temperatures up to 900 Degree-Sign C. Depending on the application, CuO or O{sub 2}-flow combustion can be used. A flow controller is used to adjust the O{sub 2} flow and pressure during combustion. For environmental samples, a module for molecular sieve regeneration and sample desorption is attached to the line replacing the combustion module. In the storage module, CO{sub 2} samples can be stored behind a gas-tight diaphragm valve and either stored for later graphitization or taken for measurements with separate equipment (AMS gas ion source or a separate mass spectrometer). The graphitization module consists of four automated reactors, capable of graphitizing samples with masses from 3 mg down to 50 {mu}g.

  14. Gel-aided sample preparation (GASP)--a simplified method for gel-assisted proteomic sample generation from protein extracts and intact cells.

    Science.gov (United States)

    Fischer, Roman; Kessler, Benedikt M

    2015-04-01

    We describe a "gel-assisted" proteomic sample preparation method for MS analysis. Solubilized protein extracts or intact cells are copolymerized with acrylamide, facilitating denaturation, reduction, quantitative cysteine alkylation, and matrix formation. Gel-aided sample preparation has been optimized to be highly flexible, scalable, and to allow reproducible sample generation from 50 cells to milligrams of protein extracts. This methodology is fast, sensitive, easy-to-use on a wide range of sample types, and accessible to nonspecialists. © 2014 The Authors. PROTEOMICS published by Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. A Proteomics Sample Preparation Method for Mature, Recalcitrant Leaves of Perennial Plants

    Science.gov (United States)

    Na, Zhang; Chengying, Lao; Bo, Wang; Dingxiang, Peng; Lijun, Liu

    2014-01-01

    Sample preparation is key to the success of proteomics studies. In the present study, two sample preparation methods were tested for their suitability on the mature, recalcitrant leaves of six representative perennial plants (grape, plum, pear, peach, orange, and ramie). An improved sample preparation method was obtained: Tris and Triton X-100 were added together instead of CHAPS to the lysis buffer, and a 20% TCA-water solution and 100% precooled acetone were added after the protein extraction for the further purification of protein. This method effectively eliminates nonprotein impurities and obtains a clear two-dimensional gel electrophoresis array. The method facilitates the separation of high-molecular-weight proteins and increases the resolution of low-abundance proteins. This method provides a widely applicable and economically feasible technology for the proteomic study of the mature, recalcitrant leaves of perennial plants. PMID:25028960

  16. A proteomics sample preparation method for mature, recalcitrant leaves of perennial plants.

    Directory of Open Access Journals (Sweden)

    Deng Gang

    Full Text Available Sample preparation is key to the success of proteomics studies. In the present study, two sample preparation methods were tested for their suitability on the mature, recalcitrant leaves of six representative perennial plants (grape, plum, pear, peach, orange, and ramie. An improved sample preparation method was obtained: Tris and Triton X-100 were added together instead of CHAPS to the lysis buffer, and a 20% TCA-water solution and 100% precooled acetone were added after the protein extraction for the further purification of protein. This method effectively eliminates nonprotein impurities and obtains a clear two-dimensional gel electrophoresis array. The method facilitates the separation of high-molecular-weight proteins and increases the resolution of low-abundance proteins. This method provides a widely applicable and economically feasible technology for the proteomic study of the mature, recalcitrant leaves of perennial plants.

  17. Advances in modern sample preparation techniques using microwaves assisted chemistry for metal species determination (W1)

    International Nuclear Information System (INIS)

    Ponard, O.F.X.

    2002-01-01

    Full text: Sample preparation has long been the bottleneck of environmental analysis for both total and species specific analysis. Digestion, extraction and preparation of the analytes are relying on a series of chemical reactions. The introduction of microwave assisted sample preparation has first been viewed as a mean to accelerate the kinetics of digestion of the matrix for total elements and fast samples preparation procedures. However, the extensive development and success of microwave digestion procedures in total elemental analysis has now allowed to have a larger insight of the perspectives offered by this technique. Microwave technologies now offer to have a precise control of the temperature and indirectly control the reaction kinetics taking place during the sample preparation procedures. Microwave assisted chemistry permits to perform simultaneously the fundamental steps required for metal species extraction and derivatization. The number of sample preparation steps used for organotin or organomercury species have been reduced to one and the total time of sample preparation brought down for a few hours to some minutes. Further, the developments of GC/ICP/MS techniques allow to routinely use speciated isotopic dilution methods has internal probe of the chemical reactions. These new approaches allow us to use the addition of the labeled species for isotopic dilution as a mean to evaluate and follow the chemical processes taking place during the extraction procedure. These procedures will help us to understand and check for the stability of the analytes during the chemistry of the sample preparation procedure and bring some insights of the chemistry taking place during the extraction. Understanding the different mechanisms involved in the sample preparation steps will allow us in return to further improve all theses procedures and bring us to the horizon of 'on-line sample preparation and detection'. (author)

  18. Relations among conceptual knowledge, procedural knowledge, and procedural flexibility in two samples differing in prior knowledge.

    Science.gov (United States)

    Schneider, Michael; Rittle-Johnson, Bethany; Star, Jon R

    2011-11-01

    Competence in many domains rests on children developing conceptual and procedural knowledge, as well as procedural flexibility. However, research on the developmental relations between these different types of knowledge has yielded unclear results, in part because little attention has been paid to the validity of the measures or to the effects of prior knowledge on the relations. To overcome these problems, we modeled the three constructs in the domain of equation solving as latent factors and tested (a) whether the predictive relations between conceptual and procedural knowledge were bidirectional, (b) whether these interrelations were moderated by prior knowledge, and (c) how both constructs contributed to procedural flexibility. We analyzed data from 2 measurement points each from two samples (Ns = 228 and 304) of middle school students who differed in prior knowledge. Conceptual and procedural knowledge had stable bidirectional relations that were not moderated by prior knowledge. Both kinds of knowledge contributed independently to procedural flexibility. The results demonstrate how changes in complex knowledge structures contribute to competence development.

  19. On the use of ultracentrifugal devices for routine sample preparation in biomolecular magic-angle-spinning NMR.

    Science.gov (United States)

    Mandal, Abhishek; Boatz, Jennifer C; Wheeler, Travis B; van der Wel, Patrick C A

    2017-03-01

    A number of recent advances in the field of magic-angle-spinning (MAS) solid-state NMR have enabled its application to a range of biological systems of ever increasing complexity. To retain biological relevance, these samples are increasingly studied in a hydrated state. At the same time, experimental feasibility requires the sample preparation process to attain a high sample concentration within the final MAS rotor. We discuss these considerations, and how they have led to a number of different approaches to MAS NMR sample preparation. We describe our experience of how custom-made (or commercially available) ultracentrifugal devices can facilitate a simple, fast and reliable sample preparation process. A number of groups have since adopted such tools, in some cases to prepare samples for sedimentation-style MAS NMR experiments. Here we argue for a more widespread adoption of their use for routine MAS NMR sample preparation.

  20. On the use of ultracentrifugal devices for routine sample preparation in biomolecular magic-angle-spinning NMR

    Energy Technology Data Exchange (ETDEWEB)

    Mandal, Abhishek; Boatz, Jennifer C. [University of Pittsburgh School of Medicine, Department of Structural Biology (United States); Wheeler, Travis B. [University of Pittsburgh School of Medicine, Department of Cell Biology (United States); Wel, Patrick C. A. van der, E-mail: vanderwel@pitt.edu [University of Pittsburgh School of Medicine, Department of Structural Biology (United States)

    2017-03-15

    A number of recent advances in the field of magic-angle-spinning (MAS) solid-state NMR have enabled its application to a range of biological systems of ever increasing complexity. To retain biological relevance, these samples are increasingly studied in a hydrated state. At the same time, experimental feasibility requires the sample preparation process to attain a high sample concentration within the final MAS rotor. We discuss these considerations, and how they have led to a number of different approaches to MAS NMR sample preparation. We describe our experience of how custom-made (or commercially available) ultracentrifugal devices can facilitate a simple, fast and reliable sample preparation process. A number of groups have since adopted such tools, in some cases to prepare samples for sedimentation-style MAS NMR experiments. Here we argue for a more widespread adoption of their use for routine MAS NMR sample preparation.

  1. On-chip sample preparation for complete blood count from raw blood.

    Science.gov (United States)

    Nguyen, John; Wei, Yuan; Zheng, Yi; Wang, Chen; Sun, Yu

    2015-03-21

    This paper describes a monolithic microfluidic device capable of on-chip sample preparation for both RBC and WBC measurements from whole blood. For the first time, on-chip sample processing (e.g. dilution, lysis, and filtration) and downstream single cell measurement were fully integrated to enable sample preparation and single cell analysis from whole blood on a single device. The device consists of two parallel sub-systems that perform sample processing and electrical measurements for measuring RBC and WBC parameters. The system provides a modular environment capable of handling solutions of various viscosities by adjusting the length of channels and precisely controlling mixing ratios, and features a new 'offset' filter configuration for increased duration of device operation. RBC concentration, mean corpuscular volume (MCV), cell distribution width, WBC concentration and differential are determined by electrical impedance measurement. Experimental characterization of over 100,000 cells from 10 patient blood samples validated the system's capability for performing on-chip raw blood processing and measurement.

  2. Difficulties in preparing a standard sample of uranium metal having traces of nitrogen

    International Nuclear Information System (INIS)

    Toteja, R.S.D.; Jangida, B.L.; Sundaresan, M.

    1991-01-01

    Normally in the analysis of uranium for nitrogen, the nitrides are hydrolysed to give NH 3 and that for standardisation purposes to approximate the closest conditions of analysis of ammonia, NH 4 Cl is added to the sample and the recovery is tested. An appropriate method will be to have a standard sample of uranium with known amounts of nitrogen to be used as reference sample. The present work describes the efforts made in the preparation of such a reference sample and a general assessment of such methods available. In present work, known microamounts of nitrogen in an enclosed volume were allowed to react at a temperature of 773 K with a fixed amount of uranium metal of nitrogen content determined chemically. As the reaction of nitrogen with uranium is essentially a surface reaction, a sample had to be homogenised by allowing the nitrided sample to melt at about 1500 K and allow the nitrogen to diffuse through so that the concentration gradient along the profile will disappear. Attempts were made to prepare such samples in the range to 40 to 100 ppm of nitrogen. The density differences of uranium nitride and uranium metal made this diffusion and homogenisation process difficult. The prepared samples were analysed by the micro-kjeldahl's method and the recoveries tested. The equipment used for the preparation of the nitrided samples, for homogenisation and analysis of the results obtained are detailed in the paper together with the assessment of the general methods. (author). 2 refs., 1 fig., 1 tab

  3. SLUDGE BATCH 5 ACCEPTANCE EVALUATION RADIONUCLIDE CONCENTRATIONS IN TANK 51 SB5 QUALIFICATION SAMPLE PREPARED AT SRNL

    International Nuclear Information System (INIS)

    Bannochie, C; Ned Bibler, N; David Diprete, D

    2008-01-01

    Presented in this report are radionuclide concentrations required as part of the program of qualifying Sludge Batch Five (SB5) for processing in the Defense Waste Processing Facility (DWPF). Part of this SB5 material is currently in Tank 51 being washed and prepared for transfer to Tank 40. The acceptance evaluation needs to be completed prior to the transfer of the material in Tank 51 to Tank 40 to complete the formation of SB5. The sludge slurry in Tank 40 has already been qualified for DWPF and is currently being processed as SB4. The radionuclide concentrations were measured or estimated in the Tank 51 SB5 Qualification Sample prepared at Savannah River National Laboratory (SRNL). This sample was prepared from the three liter sample of Tank 51 sludge slurry taken on March 21, 2008. The sample was delivered to SRNL where it was initially characterized in the Shielded Cells. Under direction of the Liquid Waste Organization it was then modified by five washes, six decants, an addition of Pu/Be from Canyon Tank 16.4, and an addition of NaNO2. This final slurry now has a composition expected to be similar to that of the slurry in Tank 51 after final preparations have been made for transfer of that slurry to Ta Determining the radionuclide concentrations in this Tank 51 SB5 Qualification Sample is part of the work requested in Technical Task Request (TTR) No. HLW-DWPF-TTR-2008-0010. The work with this qualification sample is covered by a Task Technical and Quality Assurance Plan and an Analytical Study Plan. The radionuclides included in this report are needed for the DWPF Radiological Program Evaluation, the DWPF Waste Acceptance Criteria (TSR/WAC) Evaluation, and the DWPF Solid Waste Characterization Program (TTR Task 2). Radionuclides required to meet the Waste Acceptance Product Specifications (TTR Task 5) will be measured at a later date after the slurry from Tank 51 has been transferred to Tank 40. Then a sample of the as-processed SB5 will be taken and

  4. Skin sample preparation by collagenase digestion for diclofenac quantification using LC-MS/MS after topical application.

    Science.gov (United States)

    Nirogi, Ramakrishna; Padala, Naga Surya Prakash; Boggavarapu, Rajesh Kumar; Kalaikadhiban, Ilayaraja; Ajjala, Devender Reddy; Bhyrapuneni, Gopinadh; Muddana, Nageswara Rao

    2016-06-01

    Skin is the target site to evaluate the pharmacokinetic parameters of topical applications. Sample preparation is one of the influential steps in the bioanalysis of drugs in the skin. Evaluation of dermatopharmacokinetics at preclinical stage is challenging due to lack of proper sample preparation method. There is a need for an efficient sample preparation procedure for quantification of drugs in the skin using LC-MS/MS. The skin samples treated with collagenase followed by homogenization using a bead beater represents a best-fit method resulting in uniform homogenate for reproducible results. A new approach involving enzymatic treatment and mechanical homogenization techniques were evaluated for efficient sample preparation of skin samples in the bioanalysis.

  5. A comparison of two common sample preparation techniques for lipid and fatty acid analysis in three different coral morphotypes reveals quantitative and qualitative differences.

    Science.gov (United States)

    Conlan, Jessica A; Rocker, Melissa M; Francis, David S

    2017-01-01

    Lipids are involved in a host of biochemical and physiological processes in corals. Therefore, changes in lipid composition reflect changes in the ecology, nutrition, and health of corals. As such, accurate lipid extraction, quantification, and identification is critical to obtain comprehensive insight into a coral's condition. However, discrepancies exist in sample preparation methodology globally, and it is currently unknown whether these techniques generate analogous results. This study compared the two most common sample preparation techniques for lipid analysis in corals: (1) tissue isolation by air-spraying and (2) crushing the coral in toto . Samples derived from each preparation technique were subsequently analysed to quantify lipids and their constituent classes and fatty acids in four common, scleractinian coral species representing three distinct morphotypes ( Acropora millepora , Montipora crassotuberculata , Porites cylindrica , and Pocillopora damicornis ). Results revealed substantial amounts of organic material, including lipids, retained in the skeletons of all species following air-spraying, causing a marked underestimation of total lipid concentration using this method. Moreover, lipid class and fatty acid compositions between the denuded skeleton and sprayed tissue were substantially different. In particular, the majority of the total triacylglycerol and total fatty acid concentrations were retained in the skeleton (55-69% and 56-64%, respectively). As such, the isolated, sprayed tissue cannot serve as a reliable proxy for lipid quantification or identification in the coral holobiont. The in toto crushing method is therefore recommended for coral sample preparation prior to lipid analysis to capture the lipid profile of the entire holobiont, permitting accurate diagnoses of coral condition.

  6. A comparison of two common sample preparation techniques for lipid and fatty acid analysis in three different coral morphotypes reveals quantitative and qualitative differences

    Directory of Open Access Journals (Sweden)

    Jessica A. Conlan

    2017-08-01

    Full Text Available Lipids are involved in a host of biochemical and physiological processes in corals. Therefore, changes in lipid composition reflect changes in the ecology, nutrition, and health of corals. As such, accurate lipid extraction, quantification, and identification is critical to obtain comprehensive insight into a coral’s condition. However, discrepancies exist in sample preparation methodology globally, and it is currently unknown whether these techniques generate analogous results. This study compared the two most common sample preparation techniques for lipid analysis in corals: (1 tissue isolation by air-spraying and (2 crushing the coral in toto. Samples derived from each preparation technique were subsequently analysed to quantify lipids and their constituent classes and fatty acids in four common, scleractinian coral species representing three distinct morphotypes (Acropora millepora, Montipora crassotuberculata, Porites cylindrica, and Pocillopora damicornis. Results revealed substantial amounts of organic material, including lipids, retained in the skeletons of all species following air-spraying, causing a marked underestimation of total lipid concentration using this method. Moreover, lipid class and fatty acid compositions between the denuded skeleton and sprayed tissue were substantially different. In particular, the majority of the total triacylglycerol and total fatty acid concentrations were retained in the skeleton (55–69% and 56–64%, respectively. As such, the isolated, sprayed tissue cannot serve as a reliable proxy for lipid quantification or identification in the coral holobiont. The in toto crushing method is therefore recommended for coral sample preparation prior to lipid analysis to capture the lipid profile of the entire holobiont, permitting accurate diagnoses of coral condition.

  7. imFASP: An integrated approach combining in-situ filter-aided sample pretreatment with microwave-assisted protein digestion for fast and efficient proteome sample preparation.

    Science.gov (United States)

    Zhao, Qun; Fang, Fei; Wu, Ci; Wu, Qi; Liang, Yu; Liang, Zhen; Zhang, Lihua; Zhang, Yukui

    2016-03-17

    An integrated sample preparation method, termed "imFASP", which combined in-situ filter-aided sample pretreatment and microwave-assisted trypsin digestion, was developed for preparation of microgram and even nanogram amounts of complex protein samples with high efficiency in 1 h. For imFASP method, proteins dissolved in 8 M urea were loaded onto a filter device with molecular weight cut off (MWCO) as 10 kDa, followed by in-situ protein preconcentration, denaturation, reduction, alkylation, and microwave-assisted tryptic digestion. Compared with traditional in-solution sample preparation method, imFASP method generated more protein and peptide identifications (IDs) from preparation of 45 μg Escherichia coli protein sample due to the higher efficiency, and the sample preparation throughput was significantly improved by 14 times (1 h vs. 15 h). More importantly, when the starting amounts of E. coli cell lysate decreased to nanogram level (50-500 ng), the protein and peptide identified by imFASP method were improved at least 30% and 44%, compared with traditional in-solution preparation method, suggesting dramatically higher peptide recovery of imFASP method for trace amounts of complex proteome samples. All these results demonstrate that the imFASP method developed here is of high potential for high efficient and high throughput preparation of trace amounts of complex proteome samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. A review of sample preparation and its influence on pH determination in concrete samples

    International Nuclear Information System (INIS)

    Manso, S.; Aguado, A.

    2017-01-01

    If we are to monitor the chemical processes in cementitious materials, then pH assays in the pore solutions of cement pastes, mortars, and concretes are of key importance. However, there is no standard method that regulates the sample-preparation method for pH determination. The state-of-the-art of different methods for pH determination in cementitious materials is presented in this paper and the influence of sample preparation in each case. Moreover, an experimental campaign compares three different techniques for pH determination. Its results contribute to establishing a basic criterion to help researchers select the most suitable method, depending on the purpose of the research. A simple tool is described for selecting the easiest and the most economic pH determination method, depending on the objective; especially for researchers and those with limited experience in this field.

  9. A user-friendly robotic sample preparation program for fully automated biological sample pipetting and dilution to benefit the regulated bioanalysis.

    Science.gov (United States)

    Jiang, Hao; Ouyang, Zheng; Zeng, Jianing; Yuan, Long; Zheng, Naiyu; Jemal, Mohammed; Arnold, Mark E

    2012-06-01

    Biological sample dilution is a rate-limiting step in bioanalytical sample preparation when the concentrations of samples are beyond standard curve ranges, especially when multiple dilution factors are needed in an analytical run. We have developed and validated a Microsoft Excel-based robotic sample preparation program (RSPP) that automatically transforms Watson worklist sample information (identification, sequence and dilution factor) to comma-separated value (CSV) files. The Freedom EVO liquid handler software imports and transforms the CSV files to executable worklists (.gwl files), allowing the robot to perform sample dilutions at variable dilution factors. The dynamic dilution range is 1- to 1000-fold and divided into three dilution steps: 1- to 10-, 11- to 100-, and 101- to 1000-fold. The whole process, including pipetting samples, diluting samples, and adding internal standard(s), is accomplished within 1 h for two racks of samples (96 samples/rack). This platform also supports online sample extraction (liquid-liquid extraction, solid-phase extraction, protein precipitation, etc.) using 96 multichannel arms. This fully automated and validated sample dilution and preparation process has been applied to several drug development programs. The results demonstrate that application of the RSPP for fully automated sample processing is efficient and rugged. The RSPP not only saved more than 50% of the time in sample pipetting and dilution but also reduced human errors. The generated bioanalytical data are accurate and precise; therefore, this application can be used in regulated bioanalysis.

  10. Compact low temperature scanning tunneling microscope with in-situ sample preparation capability

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jungdae [Department of Physics, The University of Texas, Austin, Texas 78712 (United States); Department of Physics and EHSRC, University of Ulsan, Ulsan 680-749 (Korea, Republic of); Nam, Hyoungdo; Schroeder, Allan; Shih, Chih-Kang, E-mail: shih@physics.utexas.edu [Department of Physics, The University of Texas, Austin, Texas 78712 (United States); Qin, Shengyong [Department of Physics, The University of Texas, Austin, Texas 78712 (United States); Department of Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China); ICQD, Hefei National Laboratory for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei, Anhui 230026 (China); Kim, Sang-ui [Department of Physics and EHSRC, University of Ulsan, Ulsan 680-749 (Korea, Republic of); Eom, Daejin [Korea Research Institute of Standards and Science, Daejeon 305-340 (Korea, Republic of)

    2015-09-15

    We report on the design of a compact low temperature scanning tunneling microscope (STM) having in-situ sample preparation capability. The in-situ sample preparation chamber was designed to be compact allowing quick transfer of samples to the STM stage, which is ideal for preparing temperature sensitive samples such as ultra-thin metal films on semiconductor substrates. Conventional spring suspensions on the STM head often cause mechanical issues. To address this problem, we developed a simple vibration damper consisting of welded metal bellows and rubber pads. In addition, we developed a novel technique to ensure an ultra-high-vacuum (UHV) seal between the copper and stainless steel, which provides excellent reliability for cryostats operating in UHV. The performance of the STM was tested from 2 K to 77 K by using epitaxial thin Pb films on Si. Very high mechanical stability was achieved with clear atomic resolution even when using cryostats operating at 77 K. At 2 K, a clean superconducting gap was observed, and the spectrum was easily fit using the BCS density of states with negligible broadening.

  11. Compact low temperature scanning tunneling microscope with in-situ sample preparation capability.

    Science.gov (United States)

    Kim, Jungdae; Nam, Hyoungdo; Qin, Shengyong; Kim, Sang-ui; Schroeder, Allan; Eom, Daejin; Shih, Chih-Kang

    2015-09-01

    We report on the design of a compact low temperature scanning tunneling microscope (STM) having in-situ sample preparation capability. The in-situ sample preparation chamber was designed to be compact allowing quick transfer of samples to the STM stage, which is ideal for preparing temperature sensitive samples such as ultra-thin metal films on semiconductor substrates. Conventional spring suspensions on the STM head often cause mechanical issues. To address this problem, we developed a simple vibration damper consisting of welded metal bellows and rubber pads. In addition, we developed a novel technique to ensure an ultra-high-vacuum (UHV) seal between the copper and stainless steel, which provides excellent reliability for cryostats operating in UHV. The performance of the STM was tested from 2 K to 77 K by using epitaxial thin Pb films on Si. Very high mechanical stability was achieved with clear atomic resolution even when using cryostats operating at 77 K. At 2 K, a clean superconducting gap was observed, and the spectrum was easily fit using the BCS density of states with negligible broadening.

  12. Automated cellular sample preparation using a Centrifuge-on-a-Chip.

    Science.gov (United States)

    Mach, Albert J; Kim, Jae Hyun; Arshi, Armin; Hur, Soojung Claire; Di Carlo, Dino

    2011-09-07

    The standard centrifuge is a laboratory instrument widely used by biologists and medical technicians for preparing cell samples. Efforts to automate the operations of concentration, cell separation, and solution exchange that a centrifuge performs in a simpler and smaller platform have had limited success. Here, we present a microfluidic chip that replicates the functions of a centrifuge without moving parts or external forces. The device operates using a purely fluid dynamic phenomenon in which cells selectively enter and are maintained in microscale vortices. Continuous and sequential operation allows enrichment of cancer cells from spiked blood samples at the mL min(-1) scale, followed by fluorescent labeling of intra- and extra-cellular antigens on the cells without the need for manual pipetting and washing steps. A versatile centrifuge-analogue may open opportunities in automated, low-cost and high-throughput sample preparation as an alternative to the standard benchtop centrifuge in standardized clinical diagnostics or resource poor settings.

  13. Ultra-High-Throughput Sample Preparation System for Lymphocyte Immunophenotyping Point-of-Care Diagnostics.

    Science.gov (United States)

    Walsh, David I; Murthy, Shashi K; Russom, Aman

    2016-10-01

    Point-of-care (POC) microfluidic devices often lack the integration of common sample preparation steps, such as preconcentration, which can limit their utility in the field. In this technology brief, we describe a system that combines the necessary sample preparation methods to perform sample-to-result analysis of large-volume (20 mL) biopsy model samples with staining of captured cells. Our platform combines centrifugal-paper microfluidic filtration and an analysis system to process large, dilute biological samples. Utilizing commercialization-friendly manufacturing methods and materials, yielding a sample throughput of 20 mL/min, and allowing for on-chip staining and imaging bring together a practical, yet powerful approach to microfluidic diagnostics of large, dilute samples. © 2016 Society for Laboratory Automation and Screening.

  14. Highly Reproducible Automated Proteomics Sample Preparation Workflow for Quantitative Mass Spectrometry.

    Science.gov (United States)

    Fu, Qin; Kowalski, Michael P; Mastali, Mitra; Parker, Sarah J; Sobhani, Kimia; van den Broek, Irene; Hunter, Christie L; Van Eyk, Jennifer E

    2018-01-05

    Sample preparation for protein quantification by mass spectrometry requires multiple processing steps including denaturation, reduction, alkylation, protease digestion, and peptide cleanup. Scaling these procedures for the analysis of numerous complex biological samples can be tedious and time-consuming, as there are many liquid transfer steps and timed reactions where technical variations can be introduced and propagated. We established an automated sample preparation workflow with a total processing time for 96 samples of 5 h, including a 2 h incubation with trypsin. Peptide cleanup is accomplished by online diversion during the LC/MS/MS analysis. In a selected reaction monitoring (SRM) assay targeting 6 plasma biomarkers and spiked β-galactosidase, mean intraday and interday cyclic voltammograms (CVs) for 5 serum and 5 plasma samples over 5 days were samples repeated on 3 separate days had total CVs below 20%. Similar results were obtained when the workflow was transferred to a second site: 93% of peptides had CVs below 20%. An automated trypsin digestion workflow yields uniformly processed samples in less than 5 h. Reproducible quantification of peptides was observed across replicates, days, instruments, and laboratory sites, demonstrating the broad applicability of this approach.

  15. Focused-microwave-assisted sample preparation (M8)

    International Nuclear Information System (INIS)

    Nobrega, J.A.; Santos, D.M.; Trevizan, L.C.; Costa, L.M.; Nogueira, A.R.A.

    2002-01-01

    Full text: Focused-microwave-assisted sample preparation is a suitable strategy when dealing with high masses of organic samples. However, the final acid concentration of the digestate can difficult routine analytical measurements using spectroscopic techniques. Acids could be evaporated, but this step could be slow even when using microwave-assisted heating and requires a scrubber system for acid vapor collection and neutralization. We are investigating two procedures to decrease the acid concentration of digestates. The first one is based on acid vapor phase digestion of samples contained in PTFE devices' inserted into the microwave flask. The acid solution is heated by absorption of microwave radiation, then the acid vapor partially condenses in the upper part of the reaction flask and it is partially collected in each sample container. Calcium, Fe, Mg, Mn, and Zn were quantitatively recovered in samples of animal and vegetable tissues. Better recoveries were attained when adding a small volume of sodium hypochlorite to the sample. This effect is probably related to the generation of chlorine in the sample container after collecting condensed acid. The second procedure developed is based on the gradual addition of liquid samples to a previously heated acid digestion mixture. This procedure was successfully applied for digestion of milk, fruit juices, and red wine. The main advantage is the possibility of digesting up to four-fold more sample using up to ten-fold lower amounts of concentrated acids. Results obtained using both digestion procedures and measurements by ICP-OES with axial view will be presented. (author)

  16. Preparation of ceramic materials for surface characterization

    International Nuclear Information System (INIS)

    Zipperian, D.C.

    1989-01-01

    This paper discusses how microstructural preparation permits a microscopic analysis of a material's internal structure, which is related to the physical properties of the material. Today, numerous microstructural quantitative and qualitative measurements are commonly utilized. Several of these include phase determination, phase hardness, phase distribution, grain size and shape, and porosity and size distribution. The most widely used surface characterization techniques are optical microscopy, electron microscopy, and x-ray microscopy. Optical microscopy includes both transmitted-and reflected-light techniques and requires a surface preparation prior to analysis. Transmitted-light microscopy samples require thinning and polishing of both sides of the sample, whereas reflected light techniques require polishing of only one side of the sample

  17. Ionic liquids: solvents and sorbents in sample preparation.

    Science.gov (United States)

    Clark, Kevin D; Emaus, Miranda N; Varona, Marcelino; Bowers, Ashley N; Anderson, Jared L

    2018-01-01

    The applications of ionic liquids (ILs) and IL-derived sorbents are rapidly expanding. By careful selection of the cation and anion components, the physicochemical properties of ILs can be altered to meet the requirements of specific applications. Reports of IL solvents possessing high selectivity for specific analytes are numerous and continue to motivate the development of new IL-based sample preparation methods that are faster, more selective, and environmentally benign compared to conventional organic solvents. The advantages of ILs have also been exploited in solid/polymer formats in which ordinarily nonspecific sorbents are functionalized with IL moieties in order to impart selectivity for an analyte or analyte class. Furthermore, new ILs that incorporate a paramagnetic component into the IL structure, known as magnetic ionic liquids (MILs), have emerged as useful solvents for bioanalytical applications. In this rapidly changing field, this Review focuses on the applications of ILs and IL-based sorbents in sample preparation with a special emphasis on liquid phase extraction techniques using ILs and MILs, IL-based solid-phase extraction, ILs in mass spectrometry, and biological applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Development of a sample preparation system for AMS radiocarbon dating at CRICH, Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myung-Jin; Lee, Byeong-Cheol; Lim, Eun-Soo [Cultural Research Institute of Chungcheong Heritage, Gongju (Korea, Republic of); Hong, Duk-Geun [Kangwon National University, Chuncheon (Korea, Republic of); Park, Soon-Bal [Chungnam National University, Daejeon (Korea, Republic of); Youn, Min-Young [Seoul National University, Seoul (Korea, Republic of)

    2010-01-15

    We developed a sample preparation system for radiocarbon dating by using AMS measurement at Cultural Research Institute of Chungcheong Heritage, Korea. From the investigation of the reduction process, the optimum graphitization temperature was chosen as 625 .deg. C. Using Aldrich graphite powder of 0.75 {+-} 0.023 pMC, the background value of our preparation system was controlled at a low level. The robustness against chemical treatment and contamination was also observed from samples of Oxalic acid II and IAEA-C4. The resultant values, 134.04 {+-} 0.99 pMC and 0.38 {+-} 0.043 pMC, were in good agreement with the consensus values. Based on comparison, our conventional ages agreed very well with those of Beta Analytic Co. and SNU-AMS. No memory effect existed in the preparation system. Therefore, we concluded that the sample preparation system was operated in a stable manner and that the basic radiocarbon dating procedures were completely verified.

  19. TCLP Preparation and Analysis of K East Basin Composite Sludge Samples

    International Nuclear Information System (INIS)

    Silvers, K.L.; Wagner, J.J.; Steele, R.T.

    2000-01-01

    Sludge samples from the Hanford K East Basin were analyzed by the Toxicity Characterization Leaching Procedure (TCLP) to assist in the appropriate Resource Conservation and Recovery Act (RCIL4) designation of this material. Sludge samples were collected by Fluor Hanford, Inc. using the consolidated sludge sampling system (system that allows collection of a single sample from multiple sample locations). These samples were shipped to the Postirradiation Testing Laboratory (PTL, 327 Building) and then transferred to the Pacific Northwest National Laboratory (PNNL) Radiochemical Processing Laboratory (RPL, 325 Building) for recovery and testing. Two sludge composites were prepared, using the consolidated sludge samples, to represent K East canister sludge (sample KC Can Comp) and K East floor sludge (sample KC Floor Comp). Each composite was extracted in duplicate and analyzed in duplicate following pre-approved(a) TCLP extraction and analyses procedures. In addition, these samples and duplicates were analyzed for total RCRA metals (via acid digestion preparation). The work was conducted in accordance with the requirements of the Hanford Analytical Quality Assurance Requirements Document (HASQARD). A PNNL Quality Assurance Program compliant with J HASQARD was implemented for this effort. The results from the TCLP analyses showed that all RCRA metal concentrations were less than the TCLP limits for both the canister and floor composite samples and their respective duplicates

  20. Capacitive deionization on-chip as a method for microfluidic sample preparation

    NARCIS (Netherlands)

    Roelofs, Susan Helena; Kim, Bumjoo; Eijkel, Jan C.T.; Han, Jongyoon; van den Berg, Albert; Odijk, Mathieu

    2015-01-01

    Desalination as a sample preparation step is essential for noise reduction and reproducibility of mass spectrometry measurements. A specific example is the analysis of proteins for medical research and clinical applications. Salts and buffers that are present in samples need to be removed before

  1. A review of sample preparation and its influence on pH determination in concrete samples

    Directory of Open Access Journals (Sweden)

    S. Manso

    2017-01-01

    Full Text Available If we are to monitor the chemical processes in cementitious materials, then pH assays in the pore solutions of cement pastes, mortars, and concretes are of key importance. However, there is no standard method that regulates the sample-preparation method for pH determination. The state-of-the-art of different methods for pH determination in cementitious materials is presented in this paper and the influence of sample preparation in each case. Moreover, an experimental campaign compares three different techniques for pH determination. Its results contribute to establishing a basic criterion to help researchers select the most suitable method, depending on the purpose of the research. A simple tool is described for selecting the easiest and the most economic pH determination method, depending on the objective; especially for researchers and those with limited experience in this field.

  2. A developed wedge fixtures assisted high precision TEM samples pre-thinning method: Towards the batch lamella preparation

    Directory of Open Access Journals (Sweden)

    Dandan Wang

    2017-04-01

    Full Text Available Ion milling, wedge cutting or polishing, and focused ion beam (FIB milling are widely-used techniques for the transmission electron microscope (TEM sample preparation. Especially, the FIB milling provides a site-specific analysis, deposition, and ablation of materials in the micrometer and nanometer scale. However, the cost of FIB tools has been always a significant concern. Since it is inevitable to use the FIB technique, the improvement of efficiency is a key point. Traditional TEM sample preparation with FIB was routinely implemented on a single sample each time. Aiming at cost efficiency, a new pre-thinning technique for batch sample preparation was developed in this paper. The present proposal combines the sample preparation techniques with multi-samples thinning, cross-section scanning electron microscopy (SEM, wedge cutting, FIB and other sample pre-thinning techniques. The new pre-thinning technique is to prepare an edge TEM sample on a grinding and polishing fixture with a slant surface. The thickness of the wedges sample can be measured to 1∼2 μm under optical microscope. Therefore, this fixture is superior to the traditional optical method of estimating the membrane thickness. Moreover, by utilizing a multi-sample holding fixture, more samples can be pre-thinned simultaneously, which significantly improved the productivity of TEM sample preparation.

  3. Techniques for preparation prior to embryo transfer

    NARCIS (Netherlands)

    Derks, Roos S.; Farquhar, Cindy; Mol, Ben Willem J.; Buckingham, Karen; Heineman, Maas Jan

    2009-01-01

    BACKGROUND: Embryo transfer (ET) is the final and most vulnerable step in in vitro fertilisation (IVF) treatment. Pregnancy rates after ET may be influenced by several factors including cervical preparation, the performance of a dummy or mock transfer, the choice of catheter, the use of ultrasound

  4. Automated injection of a radioactive sample for preparative HPLC with feedback control

    International Nuclear Information System (INIS)

    Iwata, Ren; Yamazaki, Shigeki

    1990-01-01

    The injection of a radioactive reaction mixture into a preparative HPLC column has been automated with computer control for rapid purification of routinely prepared positron emitting radiopharmaceuticals. Using pneumatic valves, a motor-driven pump and a liquid level sensor, two intelligent injection methods for the automation were compared with regard to efficient and rapid sample loading into a 2 mL loop of the 6-way valve. One, a precise but rather slow method, was demonstrated to be suitable for purification of 18 F-radiopharmaceuticals, while the other, due to its rapid operation, was more suitable for 11 C-radiopharmaceuticals. A sample volume of approx 0.5 mL can be injected onto a preparative HPLC column with over 90% efficiency with the present automated system. (author)

  5. Sample preparation and fractionation for proteome analysis and cancer biomarker discovery by mass spectrometry.

    Science.gov (United States)

    Ahmed, Farid E

    2009-03-01

    Sample preparation and fractionation technologies are one of the most crucial processes in proteomic analysis and biomarker discovery in solubilized samples. Chromatographic or electrophoretic proteomic technologies are also available for separation of cellular protein components. There are, however, considerable limitations in currently available proteomic technologies as none of them allows for the analysis of the entire proteome in a simple step because of the large number of peptides, and because of the wide concentration dynamic range of the proteome in clinical blood samples. The results of any undertaken experiment depend on the condition of the starting material. Therefore, proper experimental design and pertinent sample preparation is essential to obtain meaningful results, particularly in comparative clinical proteomics in which one is looking for minor differences between experimental (diseased) and control (nondiseased) samples. This review discusses problems associated with general and specialized strategies of sample preparation and fractionation, dealing with samples that are solution or suspension, in a frozen tissue state, or formalin-preserved tissue archival samples, and illustrates how sample processing might influence detection with mass spectrometric techniques. Strategies that dramatically improve the potential for cancer biomarker discovery in minimally invasive, blood-collected human samples are also presented.

  6. A high-throughput sample preparation method for cellular proteomics using 96-well filter plates.

    Science.gov (United States)

    Switzar, Linda; van Angeren, Jordy; Pinkse, Martijn; Kool, Jeroen; Niessen, Wilfried M A

    2013-10-01

    A high-throughput sample preparation protocol based on the use of 96-well molecular weight cutoff (MWCO) filter plates was developed for shotgun proteomics of cell lysates. All sample preparation steps, including cell lysis, buffer exchange, protein denaturation, reduction, alkylation and proteolytic digestion are performed in a 96-well plate format, making the platform extremely well suited for processing large numbers of samples and directly compatible with functional assays for cellular proteomics. In addition, the usage of a single plate for all sample preparation steps following cell lysis reduces potential samples losses and allows for automation. The MWCO filter also enables sample concentration, thereby increasing the overall sensitivity, and implementation of washing steps involving organic solvents, for example, to remove cell membranes constituents. The optimized protocol allowed for higher throughput with improved sensitivity in terms of the number of identified cellular proteins when compared to an established protocol employing gel-filtration columns. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Ergonomic analysis of radiopharmaceuticals samples preparation process

    International Nuclear Information System (INIS)

    Gomes, Luciene Betzler C.; Santos, Isaac Luquetti dos; Fonseca, Antonio Carlos C. da; Pellini, Marcos Pinto; Rebelo, Ana Maria

    2005-01-01

    The doses of radioisotopes to be administrated in patients for diagnostic effect or therapy are prepared in the radiopharmacological sector. The preparation process adopts techniques that are aimed to reduce the exposition time of the professionals and the absorption of excessive doses for patients. The ergonomic analysis of this process contributes in the prevention of occupational illnesses and to prevent risks of accidents during the routines, providing welfare and security to the involved users and conferring to the process an adequate working standard. In this context it is perceived relevance of studies that deal with the analysis of factors that point with respect to the solution of problems and for establishing proposals that minimize risks in the exercise of the activities. Through a methodology that considers the application of the concepts of Ergonomics, it is searched the improvement of the effectiveness or the quality and reduction of the difficulties lived for the workers. The work prescribed, established through norms and procedures codified will be faced with the work effectively carried through, the real work, shaped to break the correct appreciation, with focus in the activities. This work has as objective to argue an ergonomic analysis of samples preparation process of radioisotopes in the Setor de Radiofarmacia do Hospital Universitario Clementino Fraga Filho da Universidade Federal do Rio de Janeiro (UFRJ). (author)

  8. Improved sample preparation and counting techniques for enhanced tritium measurement sensitivity

    Science.gov (United States)

    Moran, J.; Aalseth, C.; Bailey, V. L.; Mace, E. K.; Overman, C.; Seifert, A.; Wilcox Freeburg, E. D.

    2015-12-01

    Tritium (T) measurements offer insight to a wealth of environmental applications including hydrologic tracking, discerning ocean circulation patterns, and aging ice formations. However, the relatively short half-life of T (12.3 years) limits its effective age dating range. Compounding this limitation is the decrease in atmospheric T content by over two orders of magnitude (from 1000-2000 TU in 1962 to testing in the 1960's. We are developing sample preparation methods coupled to direct counting of T via ultra-low background proportional counters which, when combined, offer improved T measurement sensitivity (~4.5 mmoles of H2 equivalent) and will help expand the application of T age dating to smaller sample sizes linked to persistent environmental questions despite the limitations above. For instance, this approach can be used to T date ~ 2.2 mmoles of CH4 collected from sample-limited systems including microbial communities, soils, or subsurface aquifers and can be combined with radiocarbon dating to distinguish the methane's formation age from C age in a system. This approach can also expand investigations into soil organic C where the improved sensitivity will permit resolution of soil C into more descriptive fractions and provide direct assessments of the stability of specific classes of organic matter in soils environments. We are employing a multiple step sample preparation system whereby organic samples are first combusted with resulting CO2 and H2O being used as a feedstock to synthesize CH4. This CH4 is mixed with Ar and loaded directly into an ultra-low background proportional counter for measurement of T β decay in a shallow underground laboratory. Analysis of water samples requires only the addition of geologic CO2 feedstock with the sample for methane synthesis. The chemical nature of the preparation techniques enable high sample throughput with only the final measurement requiring T decay with total sample analysis time ranging from 2 -5 weeks

  9. Preparation and application of radioactive soil samples for intercomparison

    International Nuclear Information System (INIS)

    Gao Zequan; Li Zhou; Li Pengxiang; Wang Ruijun; Ren Xiaona

    2014-01-01

    This article summarized the preparation process and intercomparison results of the simulated environmental radioactive soil samples. The components of the matrix were: SiO 2 , Al 2 O 3 , Fe 2 O 3 , MgO, CaO, NaCl, KCl and TiO 2 . All of the components were milled, oven-dried, sieved and then blended together. The homogeneity test was according to GB 15000. 5-1994, and no significant differences were observed. The 3 H analysis soils were spiked natural soils with the moisture content of 15%. Eight laboratories attended this intercomparison. The results proves that the preparation of the simulated soils were suitable for the inter-laboratories comparison. (authors)

  10. Preparation of rock samples for measurement of the thermal neutron macroscopic absorption cross-section

    International Nuclear Information System (INIS)

    Czubek, J.A.; Burda, J.; Drozdowicz, K.; Igielski, A.; Kowalik, W.; Krynicka-Drozdowicz, E.; Woznicka, U.

    1986-03-01

    Preparation of rock samples for the measurement of the thermal neutron macroscopic absorption cross-section in small cylindrical two-region systems by a pulsed technique is presented. Requirements which should be fulfilled during the preparation of the samples due to physical assumptions of the method are given. A cylindrical vessel is filled with crushed rock and saturated with a medium strongly absorbing thermal neutrons. Water solutions of boric acid of well-known macroscopic absorption cross-section are used. Mass contributions of the components in the sample are specified. This is necessary for the calculation of the thermal neutron macroscopic absorption cross-section of the rock matrix. The conditions necessary for assuring the required accuracy of the measurement are given and the detailed procedure of preparation of the rock sample is described. (author)

  11. PREFERENCE OF PRIOR FOR BAYESIAN ANALYSIS OF THE MIXED BURR TYPE X DISTRIBUTION UNDER TYPE I CENSORED SAMPLES

    Directory of Open Access Journals (Sweden)

    Tabassum Naz Sindhu

    2014-05-01

    Full Text Available The paper is concerned with the preference of prior for the Bayesian analysis of the shape parameter of the mixture of Burr type X distribution using the censored data. We modeled the heterogeneous population using two components mixture of the Burr type X distribution. A comprehensive simulation scheme, through probabilistic mixing, has been followed to highlight the properties and behavior of the estimates in terms of sample size, corresponding risks and the proportion of the component of the mixture. The Bayes estimators of the parameters have been evaluated under the assumption of informative and non-informative priors using symmetric and asymmetric loss functions. The model selection criterion for the preference of the prior has been introduced. The hazard rate function of the mixture distribution has been discussed. The Bayes estimates under exponential prior and precautionary loss function exhibit the minimum posterior risks with some exceptions.

  12. Should the mass of a nanoferrite sample prepared by autocombustion method be considered as a realistic preparation parameter?

    Energy Technology Data Exchange (ETDEWEB)

    Wahba, Adel Maher, E-mail: adel.mousa@f-eng.tanta.edu.eg [Department of Engineering Physics and Mathematics, Faculty of Engineering, Tanta University (Egypt); Mohamed, Mohamed Bakr [Ain shams University, Faculty of Science, Physics Department, Cairo (Egypt)

    2017-02-15

    Detectable variations in structural, elastic and magnetic properties have been reported depending on the mass of the cobalt nanoferrite sample prepared by citrate autocombustion method. Heat released during the autocombustion process and its duration are directly proportional to the mass to be prepared, and is thus expected to affect both the crystallite size and the cation distribution giving rise to the reported variations in microstrain, magnetization, and coercivity. Formation of a pure spinel phase has been validated using X-ray diffraction patterns (XRD) and Fourier-transform infrared (FTIR) spectra. Crystallite sizes obtained from Williamson-Hall (W-H) method range from 28–87 nm, being further supported by images of high-resolution transmission electron microscope (HRTEM). Saturation magnetization and coercivity deduced from M-H hysteresis loops show a clear correlation with the cation distribution, which was proposed on the basis of experimentally obtained data of XRD, VSM, and IR. Elastic parameters have been estimated using the cation distribution and FTIR data, with a resulting trend quite opposite to that of the lattice parameter. - Highlights: • Samples with different masses of CoFe{sub 2}O{sub 4} were prepared by autocombustion method. • XRD and IR data confirmed a pure spinel cubic structure for all samples. • Structural and magnetic properties show detectable changes with the mass prepared. • Cation distribution was suggested from experimental data of XRD, IR, and M-H loops.

  13. Experiences from Refurbishment of Metallography Hot Cells and Application of a New Preparation Concept for Materialography Samples

    International Nuclear Information System (INIS)

    Oberlander, B. C.; Espeland, M.; Solum, N. O.

    2001-01-01

    After more than 30 years of operation the lead shielded metallography hot cells needed a basic renewal and modernisation not least of the specimen preparation equipment. Preparation in hot cells of radioactive samples for metallography and ceramography is challenging and time consuming. It demands a special design and quality of all in-cell equipment and skill and patience from the operator. Essentials in the preparation process are: simplicity and reliability of the machines, and a good quality, reproducibility and efficiency in performance. Desirable is process automation, flexibility and an alara amounto of radioactive waste produced per sample prepared. State of the art preparation equipment for materialography seems to meet most of the demands, however, it cannot be used in hot cells without modifications. Therefore. IFE and Struers in Copenhagen modified a standard model of a Strues precision cutting machine and a microprocessor controlled grinding and polishing machine for Hot Cell application. Hot cell utilisation of the microcomputer controlled grinding and polishing machine and the existing automatic dosing equipment made the task of preparing radioactive samples more attractive. The new grinding and polishing system for hot cells provides good sample preparation quality and reproductibility at reduced preparation time and reduced amount of contaminated waste produced per sample prepared. the sample materials examined were irradiated cladding materials and fuels

  14. Radiocarbon accelerator mass spectrometry (AMS) sample preparation laboratory in Brazil

    International Nuclear Information System (INIS)

    Macario, Kita D.; Gomes, Paulo R. S.; Anjos, Roberto M. dos; Linares, Roberto; Queiroz, Eduardo; Oliveira, Fabiana M. de; Cardozo, Laio; Carvalho, Carla R.A.

    2011-01-01

    Full text: For decades Accelerator Mass Spectrometry has been widely used for radiocarbon measurements all over the world with application in several fields of science from archaeology to geosciences. This technique provides ultrasensitive analysis of reduced size samples or even specific compounds since sample atoms are accelerated to high energies and measured using nuclear particle detectors. Sample preparation is extremely important for accurate radiocarbon measurement and includes chemical pre-treatment to remove all possible contaminants. For beam extraction in the accelerator ion source, samples are usually converted to graphite. In this work we report a new radiocarbon sample preparation facility installed at the Physics Institute of Universidade Federal Fluminense (UFF), in Brazil. At the Nuclear Chronology Laboratory (LACRON) samples are chemically treated and converted to carbon dioxide by hydrolysis or combustion. A stainless steel based vacuum line was constructed for carbon dioxide separation and graphitization is performed in sealed quartz tubes in a muffle oven. Successful graphite production is important to provide stable beam currents and to minimize isotopic fractionation. Performance tests for graphite production are currently under way and isotopic analysis will soon be possible with the acquisition of a Single Stage AMS System by our group. The Single Stage Accelerator produced by National Electrostatic Corporation is a 250 kV air insulated accelerator especially constructed to measure the amount of 14 C in small modern graphite samples to a precision of 0.3 % or better. With the installation of such equipment in the first half of 2012, UFF will be ready to perform the 14C -AMS technique. (author)

  15. TruSeq Stranded mRNA and Total RNA Sample Preparation Kits

    Science.gov (United States)

    Total RNA-Seq enabled by ribosomal RNA (rRNA) reduction is compatible with formalin-fixed paraffin embedded (FFPE) samples, which contain potentially critical biological information. The family of TruSeq Stranded Total RNA sample preparation kits provides a unique combination of unmatched data quality for both mRNA and whole-transcriptome analyses, robust interrogation of both standard and low-quality samples and workflows compatible with a wide range of study designs.

  16. Preparation and characterisation of magnetic nanostructured samples for inelastic neutron scattering experiments

    Energy Technology Data Exchange (ETDEWEB)

    Kreuzpaintner, Wolfgang

    2010-06-22

    Recent advances in thin-film structuring techniques have generated significant interest in the dynamics of spin waves in magnetic nanostructures and the possible use of inelastic neutron scattering (INS) for their investigation. This thesis describes the design and implementation, at GKSS Research Centre, of equipment for preparation of large and laterally submicron and nanometre structured magnetic samples for such future INS experiments. After a brief resume on spin waves in nanostructures, the development work on new purpose-designed equipment, including high vacuum (HV) argon ion beam milling and ultra high vacuum (UHV) e-beam evaporation setups, is described. Ni nanodot as well as Ni and novel Gd nanowire samples were prepared using combinations of sputter deposition, laser interference lithography, argon ion beam milling, e-beam evaporation and self organisation techniques. With reference to sample preparation, epitaxial growth studies for Ni on Si(100) substrate were performed, resulting in the development of a new deposition process, which by thermal tuning allows for the direct epitaxial growth of Ni on Si with unprecedented crystalline quality. The results of various characterisation experiments on the prepared nanostructured samples, including Scanning Electron Microscopy (SEM), microprobe analysis, Atomic and Magnetic Force Microscopy (AFM/MFM), Vibrating Sample Magnetometry (VSM), X-ray Diffraction (XRD) and Reflectivity (XRR), unpolarised and Polarised Neutron Scattering (PNR) and off-specular scattering by X-rays and neutrons using rocking scans and Time-Of-Flight Grazing Incidence Small Angle Neutron Scattering (TOF-GISANS), together with various analysis procedures such as Distorted-Wave Born Approximation (DWBA), are reported. The analysis of a Gd nanowire sample by TOF-GISANS led to a novel evaluation technique which in comparison with single wavelength methods allows portions of reciprocal space to be scanned without changing the angle of

  17. Preparation and characterisation of magnetic nanostructured samples for inelastic neutron scattering experiments

    International Nuclear Information System (INIS)

    Kreuzpaintner, Wolfgang

    2010-01-01

    Recent advances in thin-film structuring techniques have generated significant interest in the dynamics of spin waves in magnetic nanostructures and the possible use of inelastic neutron scattering (INS) for their investigation. This thesis describes the design and implementation, at GKSS Research Centre, of equipment for preparation of large and laterally submicron and nanometre structured magnetic samples for such future INS experiments. After a brief resume on spin waves in nanostructures, the development work on new purpose-designed equipment, including high vacuum (HV) argon ion beam milling and ultra high vacuum (UHV) e-beam evaporation setups, is described. Ni nanodot as well as Ni and novel Gd nanowire samples were prepared using combinations of sputter deposition, laser interference lithography, argon ion beam milling, e-beam evaporation and self organisation techniques. With reference to sample preparation, epitaxial growth studies for Ni on Si(100) substrate were performed, resulting in the development of a new deposition process, which by thermal tuning allows for the direct epitaxial growth of Ni on Si with unprecedented crystalline quality. The results of various characterisation experiments on the prepared nanostructured samples, including Scanning Electron Microscopy (SEM), microprobe analysis, Atomic and Magnetic Force Microscopy (AFM/MFM), Vibrating Sample Magnetometry (VSM), X-ray Diffraction (XRD) and Reflectivity (XRR), unpolarised and Polarised Neutron Scattering (PNR) and off-specular scattering by X-rays and neutrons using rocking scans and Time-Of-Flight Grazing Incidence Small Angle Neutron Scattering (TOF-GISANS), together with various analysis procedures such as Distorted-Wave Born Approximation (DWBA), are reported. The analysis of a Gd nanowire sample by TOF-GISANS led to a novel evaluation technique which in comparison with single wavelength methods allows portions of reciprocal space to be scanned without changing the angle of

  18. Infrared biospectroscopy for a fast qualitative evaluation of sample preparation in metabolomics.

    Science.gov (United States)

    Kuligowski, Julia; Pérez-Guaita, David; Escobar, Javier; Lliso, Isabel; de la Guardia, Miguel; Lendl, Bernhard; Vento, Máximo; Quintás, Guillermo

    2014-09-01

    Liquid chromatography-mass spectrometry (LC-MS) has been increasingly used in biomedicine to study the dynamic metabolomic responses of biological systems under different physiological or pathological conditions. To obtain an integrated snapshot of the system, metabolomic methods in biomedicine typically analyze biofluids (e.g. plasma) that require clean-up before being injected into LC-MS systems. However, high resolution LC-MS is costly in terms of resources required for sample and data analysis and care must be taken to prevent chemical (e.g. ion suppression) or statistical artifacts. Because of that, the effect of sample preparation on the metabolomic profile during metabolomic method development is often overlooked. This work combines an Attenuated Total Reflectance-Fourier transform infrared (ATR-FTIR) and a multivariate exploratory data analysis for a cost-effective qualitative evaluation of major changes in sample composition during sample preparation. ATR-FTIR and LC-time of flight mass spectrometry (TOFMS) data from the analysis of a set of plasma samples precipitated using acetonitrile, methanol and acetone performed in parallel were used as a model example. Biochemical information obtained from the analysis of the ATR-FTIR and LC-TOFMS data was thoroughly compared to evaluate the strengths and shortcomings of FTIR biospectroscopy for assessing sample preparation in metabolomics studies. Results obtained show the feasibility of ATR-FTIR for the evaluation of major trends in the plasma composition changes among different sample pretreatments, providing information in terms of e.g., amino acids, proteins, lipids and carbohydrates overall contents comparable to those found by LC-TOFMS. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Application of hydrocyanic acid vapor generation via focused microwave radiation to the preparation of industrial effluent samples prior to free and total cyanide determinations by spectrophotometric flow injection analysis.

    Science.gov (United States)

    Quaresma, Maria Cristina Baptista; de Carvalho, Maria de Fátima Batista; Meirelles, Francis Assis; Santiago, Vânia Maria Junqueira; Santelli, Ricardo Erthal

    2007-02-01

    A sample preparation procedure for the quantitative determination of free and total cyanides in industrial effluents has been developed that involves hydrocyanic acid vapor generation via focused microwave radiation. Hydrocyanic acid vapor was generated from free cyanides using only 5 min of irradiation time (90 W power) and a purge time of 5 min. The HCN generated was absorbed into an accepting NaOH solution using very simple glassware apparatus that was appropriate for the microwave oven cavity. After that, the cyanide concentration was determined within 90 s using a well-known spectrophotometric flow injection analysis system. Total cyanide analysis required 15 min irradiation time (90 W power), as well as chemical conditions such as the presence of EDTA-acetate buffer solution or ascorbic acid, depending on the effluent to be analyzed (petroleum refinery or electroplating effluents, respectively). The detection limit was 0.018 mg CN l(-1) (quantification limit of 0.05 mg CN l(-1)), and the measured RSD was better than 8% for ten independent analyses of effluent samples (1.4 mg l(-1) cyanide). The accuracy of the procedure was assessed via analyte spiking (with free and complex cyanides) and by performing an independent sample analysis based on the standard methodology recommended by the APHA for comparison. The sample preparation procedure takes only 10 min for free and 20 min for total cyanide, making this procedure much faster than traditional methodologies (conventional heating and distillation), which are time-consuming (they require at least 1 h). Samples from oil (sour and stripping tower bottom waters) and electroplating effluents were analyzed successfully.

  20. Highly oriented Bi-system bulk sample prepared by a decomposition-crystallization process

    International Nuclear Information System (INIS)

    Xi Zhengping; Zhou Lian; Ji Chunlin

    1992-01-01

    A decomposition-crystallization method, preparing highly oriented Bi-system bulk sample is reported. The effects of processing parameter, decomposition temperature, cooling rate and post-treatment condition on texture and superconductivity are investigated. The method has successfully prepared highly textured Bi-system bulk samples. High temperature annealing does not destroy the growing texture, but the cooling rate has some effect on texture and superconductivity. Annealing in N 2 /O 2 atmosphere can improve superconductivity of the textured sample. The study on the superconductivity of the Bi(Pb)-Sr-Ca-Cu-O bulk material has been reported in numerous papers. The research on J c concentrates on the tape containing the 2223 phase, with very few studies on the J c of bulk sample. The reason for the lack of studies is that the change of superconducting phases at high temperatures has not been known. The authors have reported that the 2212 phase incongruently melted at about 875 degrees C and proceeded to orient the c-axis perpendicular to the surface in the process of crystallization of the 2212 phase. Based on that result, a decomposition-crystallization method was proposed to prepare highly oriented Bi-system bulk sample. In this paper, the process is described in detail and the effects of processing parameters on texture and superconductivity are reported

  1. X-ray diffraction without sample preparation: Proof-of-principle experiments

    International Nuclear Information System (INIS)

    Hansford, Graeme M.

    2013-01-01

    The properties of a novel X-ray diffraction (XRD) technique having very low sensitivity to the sample morphology were previously elucidated through theoretical considerations and model simulations (Hansford, 2011). This technique opens up the possibility of mineralogical analysis by XRD without sample preparation. Here, the results of proof-of-principle experimental tests are presented. Two sets of experiments were performed using a vacuum chamber equipped with an X-ray tube source, sample holder and charge-coupled detector. Firstly, a pressed-powder pellet of α-quartz was placed in three different positions relative to the X-ray source and detector. The changes in position represent gross sample movements which would be inconceivable in conventional XRD analysis. The resulting back-reflection energy-dispersive spectra show a very high degree of correspondence other than an overall intensity factor dependent on the distance between the sample and detector. Secondly, the back-reflection spectrum of an unprepared limestone hand specimen, having mm-scale surface morphology, was compared to the spectrum of a calcite pressed-powder pellet. The correspondence of the diffraction peaks in the spectra demonstrate that the limestone is comprised dominantly of calcite. In both cases, the claims of the earlier paper are fully supported by the results of these experimental tests. -- Highlights: • Proof-of-principle tests of a novel X-ray diffraction (XRD) method were conducted. • Very low sensitivity to sample position and orientation was demonstrated. • Insensitivity to sample morphology is inferred. • A simple analysis of an unprepared limestone hand specimen was performed. • This technique enables mineralogical analysis by XRD without sample preparation

  2. The role of graphene-based sorbents in modern sample preparation techniques.

    Science.gov (United States)

    de Toffoli, Ana Lúcia; Maciel, Edvaldo Vasconcelos Soares; Fumes, Bruno Henrique; Lanças, Fernando Mauro

    2018-01-01

    The application of graphene-based sorbents in sample preparation techniques has increased significantly since 2011. These materials have good physicochemical properties to be used as sorbent and have shown excellent results in different sample preparation techniques. Graphene and its precursor graphene oxide have been considered to be good candidates to improve the extraction and concentration of different classes of target compounds (e.g., parabens, polycyclic aromatic hydrocarbon, pyrethroids, triazines, and so on) present in complex matrices. Its applications have been employed during the analysis of different matrices (e.g., environmental, biological and food). In this review, we highlight the most important characteristics of graphene-based material, their properties, synthesis routes, and the most important applications in both off-line and on-line sample preparation techniques. The discussion of the off-line approaches includes methods derived from conventional solid-phase extraction focusing on the miniaturized magnetic and dispersive modes. The modes of microextraction techniques called stir bar sorptive extraction, solid phase microextraction, and microextraction by packed sorbent are discussed. The on-line approaches focus on the use of graphene-based material mainly in on-line solid phase extraction, its variation called in-tube solid-phase microextraction, and on-line microdialysis systems. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Preparation and validation of gross alpha/beta samples used in EML's quality assessment program

    International Nuclear Information System (INIS)

    Scarpitta, S.C.

    1997-10-01

    A set of water and filter samples have been incorporated into the existing Environmental Measurements Laboratory's (EML) Quality Assessment Program (QAP) for gross alpha/beta determinations by participating DOE laboratories. The participating laboratories are evaluated by comparing their results with the EML value. The preferred EML method for measuring water and filter samples, described in this report, uses gas flow proportional counters with 2 in. detectors. Procedures for sample preparation, quality control and instrument calibration are presented. Liquid scintillation (LS) counting is an alternative technique that is suitable for quantifying both the alpha ( 241 Am, 230 Th and 238 Pu) and beta ( 90 Sr/ 90 Y) activity concentrations in the solutions used to prepare the QAP water and air filter samples. Three LS counting techniques (Cerenkov, dual dpm and full spectrum analysis) are compared. These techniques may be used to validate the activity concentrations of each component in the alpha/beta solution before the QAP samples are actually prepared

  4. Sample preparation and characterization of technetium metal

    International Nuclear Information System (INIS)

    Minato, Kazuo; Serizawa, Hiroyuki; Fukuda, Kousaku; Itoh, Mitsuo

    1997-10-01

    Technetium-99 is a long-lived fission product with a half-life of about 2.1 x 10 5 years, which decays by β-emission. For the transmutation of 99 Tc, research on solid technetium was started. Technetium metal powder purchased was analyzed by X-ray diffraction, γ-ray spectrometry, and inductively coupled plasma-atomic emission spectrometry and -mass spectrometry. The lattice parameters obtained were agreed with the reported values. The metallic impurity was about 15 ppm, where aluminum and iron contributed mainly. No impurity nuclide with γ-emission was found. Using the technetium metal powder, button-, rod-, and disk-shaped samples of technetium metal were prepared by arc-melting technique. Thermal diffusivity of technetium metal was measured on a disk sample from room temperature to 1173 K by laser flash method. The thermal diffusivity decreased with increasing temperature though it was almost constant above 600 K. (author)

  5. Comparison of leach results from field and laboratory prepared samples

    International Nuclear Information System (INIS)

    Oblath, S.B.; Langton, C.A.

    1985-01-01

    The leach behavior of saltstone prepared in the laboratory agrees well with that from samples mixed in the field using the Littleford mixer. Leach rates of nitrates and cesium from the current reference formulation saltstone were compared. The laboratory samples were prepared using simulated salt solution; those in the field used Tank 50 decontaminated supernate. For both nitrate and cesium, the field and laboratory samples showed nearly identical leach rates for the first 30 to 50 days. For the remaining period of the test, the field samples showed higher leach rates with the maximum difference being less than a factor of three. Ruthenium and antimony were present in the Tank 50 supernate in known amounts. Antimony-125 was observed in the leachate and a fractional leach rate was calculated to be at least a factor of ten less than that of 137 Cs. No 106 Ru was observed in the leachate, and the release rate was not calculated. However, based on the detection limits for the analysis, the ruthenium leach rate must also be at least a factor of ten less than cesium. These data are the first measurements of the leach rates of Ru and Sb from saltstone. The nitrate leach rates for these samples were 5 x 10 -5 grams of nitrate per square cm per day after 100 days for the laboratory samples and after 200 days for the field samples. These values are consistent with the previously measured leach rates for reference formulation saltstone. The relative standard deviation in the leach rate is about 15% for the field samples, which all were produced from one batch of saltstone, and about 35% for the laboratory samples, which came from different batches. These are the first recorded estimates of the error in leach rates for saltstone

  6. The NOSAMS sample preparation laboratory in the next millenium: Progress after the WOCE program

    International Nuclear Information System (INIS)

    Gagnon, Alan R.; McNichol, Ann P.; Donoghue, Joanne C.; Stuart, Dana R.; Reden, Karl von

    2000-01-01

    Since 1991, the primary charge of the National Ocean Sciences AMS (NOSAMS) facility at the Woods Hole Oceanographic Institution has been to supply high throughput, high precision AMS 14 C analyses for seawater samples collected as part of the World Ocean Circulation Experiment (WOCE). Approximately 13,000 samples taken as part of WOCE should be fully analyzed by the end of Y2K. Additional sample sources and techniques must be identified and incorporated if NOSAMS is to continue in its present operation mode. A trend in AMS today is the ability to routinely process and analyze radiocarbon samples that contain tiny amounts ( 14 C analysis has been recognized as a major facility goal. The installation of a new 134-position MC-SNICS ion source, which utilizes a smaller graphite target cartridge than presently used, is one step towards realizing this goal. New preparation systems constructed in the sample preparation laboratory (SPL) include an automated bank of 10 small-volume graphite reactors, an automated system to process organic carbon samples, and a multi-dimensional preparative capillary gas chromatograph (PCGC)

  7. Collection and preparation of bottom sediment samples for analysis of radionuclides and trace elements

    International Nuclear Information System (INIS)

    2003-07-01

    The publication is the first in a series of TECDOCs on sampling and sample handling as part of the IAEA support to improve reliability of nuclear analytical techniques (NATs) in Member State laboratories. The purpose of the document is to provide information on the methods for collecting sediments, the equipment used, and the sample preparation techniques for radionuclide and elemental analysis. The most appropriate procedures for defining the strategies and criteria for selecting sampling locations, for sample storage and transportation are also given. Elements of QA/QC and documentation needs for sampling and sediment analysis are discussed. Collection and preparation of stream and river bottom sediments, lake bottom sediments, estuary bottom sediments, and marine (shallow) bottom sediments are covered. The document is intended to be a comprehensive manual for the collection and preparation of bottom sediments as a prerequisite to obtain representative and meaningful results using NATs. Quality assurance and quality control (QA/QC) is emphasized as an important aspect to ensure proper collection, transportation, preservation, and analysis since it forms the basis for interpretation and legislation. Although there are many approaches and methods available for sediment analyses, the scope of the report is limited to sample preparation for (1) analysis of radionuclides (including sediment dating using radionuclides such as Pb-210 and Cs-137) and (2) analysis of trace, minor and major elements using nuclear and related analytical techniques such as NAA, XRF and PIXE

  8. Collection and preparation of bottom sediment samples for analysis of radionuclides and trace elements

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    The publication is the first in a series of TECDOCs on sampling and sample handling as part of the IAEA support to improve reliability of nuclear analytical techniques (NATs) in Member State laboratories. The purpose of the document is to provide information on the methods for collecting sediments, the equipment used, and the sample preparation techniques for radionuclide and elemental analysis. The most appropriate procedures for defining the strategies and criteria for selecting sampling locations, for sample storage and transportation are also given. Elements of QA/QC and documentation needs for sampling and sediment analysis are discussed. Collection and preparation of stream and river bottom sediments, lake bottom sediments, estuary bottom sediments, and marine (shallow) bottom sediments are covered. The document is intended to be a comprehensive manual for the collection and preparation of bottom sediments as a prerequisite to obtain representative and meaningful results using NATs. Quality assurance and quality control (QA/QC) is emphasized as an important aspect to ensure proper collection, transportation, preservation, and analysis since it forms the basis for interpretation and legislation. Although there are many approaches and methods available for sediment analyses, the scope of the report is limited to sample preparation for (1) analysis of radionuclides (including sediment dating using radionuclides such as Pb-210 and Cs-137) and (2) analysis of trace, minor and major elements using nuclear and related analytical techniques such as NAA, XRF and PIXE.

  9. Microfluidic devices for sample preparation and rapid detection of foodborne pathogens.

    Science.gov (United States)

    Kant, Krishna; Shahbazi, Mohammad-Ali; Dave, Vivek Priy; Ngo, Tien Anh; Chidambara, Vinayaka Aaydha; Than, Linh Quyen; Bang, Dang Duong; Wolff, Anders

    2018-03-10

    Rapid detection of foodborne pathogens at an early stage is imperative for preventing the outbreak of foodborne diseases, known as serious threats to human health. Conventional bacterial culturing methods for foodborne pathogen detection are time consuming, laborious, and with poor pathogen diagnosis competences. This has prompted researchers to call the current status of detection approaches into question and leverage new technologies for superior pathogen sensing outcomes. Novel strategies mainly rely on incorporating all the steps from sample preparation to detection in miniaturized devices for online monitoring of pathogens with high accuracy and sensitivity in a time-saving and cost effective manner. Lab on chip is a blooming area in diagnosis, which exploits different mechanical and biological techniques to detect very low concentrations of pathogens in food samples. This is achieved through streamlining the sample handling and concentrating procedures, which will subsequently reduce human errors and enhance the accuracy of the sensing methods. Integration of sample preparation techniques into these devices can effectively minimize the impact of complex food matrix on pathogen diagnosis and improve the limit of detections. Integration of pathogen capturing bio-receptors on microfluidic devices is a crucial step, which can facilitate recognition abilities in harsh chemical and physical conditions, offering a great commercial benefit to the food-manufacturing sector. This article reviews recent advances in current state-of-the-art of sample preparation and concentration from food matrices with focus on bacterial capturing methods and sensing technologies, along with their advantages and limitations when integrated into microfluidic devices for online rapid detection of pathogens in foods and food production line. Copyright © 2018. Published by Elsevier Inc.

  10. Rapid immunohistochemical diagnosis of tobacco mosaic virus disease by microwave-assisted plant sample preparation

    Science.gov (United States)

    Zellnig, Günther; Möstl, Stefan; Zechmann, Bernd

    2013-01-01

    Immunoelectron microscopy is a powerful method to diagnose viral diseases and to study the distribution of the viral agent within plant cells and tissues. Nevertheless, current protocols for the immunological detection of viral diseases with transmission electron microscopy (TEM) in plants take between 3 and 6 days and are therefore not suited for rapid diagnosis of virus diseases in plants. In this study, we describe a method that allows rapid cytohistochemical detection of tobacco mosaic virus (TMV) in leaves of tobacco plants. With the help of microwave irradiation, sample preparation of the leaves was reduced to 90 min. After sample sectioning, virus particles were stained on the sections by immunogold labelling of the viral coat protein, which took 100 min. After investigation with the TEM, a clear visualization of TMV in tobacco cells was achieved altogether in about half a day. Comparison of gold particle density by image analysis revealed that samples prepared with the help of microwave irradiation yielded significantly higher gold particle density as samples prepared conventionally at room temperature. This study clearly demonstrates that microwave-assisted plant sample preparation in combination with cytohistochemical localization of viral coat protein is well suited for rapid diagnosis of plant virus diseases in altogether about half a day by TEM. PMID:23580761

  11. Protocols for the analytical characterization of therapeutic monoclonal antibodies. II - Enzymatic and chemical sample preparation.

    Science.gov (United States)

    Bobaly, Balazs; D'Atri, Valentina; Goyon, Alexandre; Colas, Olivier; Beck, Alain; Fekete, Szabolcs; Guillarme, Davy

    2017-08-15

    The analytical characterization of therapeutic monoclonal antibodies and related proteins usually incorporates various sample preparation methodologies. Indeed, quantitative and qualitative information can be enhanced by simplifying the sample, thanks to the removal of sources of heterogeneity (e.g. N-glycans) and/or by decreasing the molecular size of the tested protein by enzymatic or chemical fragmentation. These approaches make the sample more suitable for chromatographic and mass spectrometric analysis. Structural elucidation and quality control (QC) analysis of biopharmaceutics are usually performed at intact, subunit and peptide levels. In this paper, general sample preparation approaches used to attain peptide, subunit and glycan level analysis are overviewed. Protocols are described to perform tryptic proteolysis, IdeS and papain digestion, reduction as well as deglycosylation by PNGase F and EndoS2 enzymes. Both historical and modern sample preparation methods were compared and evaluated using rituximab and trastuzumab, two reference therapeutic mAb products approved by Food and Drug Administration (FDA) and European Medicines Agency (EMA). The described protocols may help analysts to develop sample preparation methods in the field of therapeutic protein analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. The NOSAMS sample preparation laboratory in the next millenium: Progress after the WOCE program

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Alan R. E-mail: agagnon@whoi.edu; McNichol, Ann P.; Donoghue, Joanne C.; Stuart, Dana R.; Reden, Karl von

    2000-10-01

    Since 1991, the primary charge of the National Ocean Sciences AMS (NOSAMS) facility at the Woods Hole Oceanographic Institution has been to supply high throughput, high precision AMS {sup 14}C analyses for seawater samples collected as part of the World Ocean Circulation Experiment (WOCE). Approximately 13,000 samples taken as part of WOCE should be fully analyzed by the end of Y2K. Additional sample sources and techniques must be identified and incorporated if NOSAMS is to continue in its present operation mode. A trend in AMS today is the ability to routinely process and analyze radiocarbon samples that contain tiny amounts (<100 {mu}g) of carbon. The capability to mass-produce small samples for {sup 14}C analysis has been recognized as a major facility goal. The installation of a new 134-position MC-SNICS ion source, which utilizes a smaller graphite target cartridge than presently used, is one step towards realizing this goal. New preparation systems constructed in the sample preparation laboratory (SPL) include an automated bank of 10 small-volume graphite reactors, an automated system to process organic carbon samples, and a multi-dimensional preparative capillary gas chromatograph (PCGC)

  13. Sample preparation method for induced mutation on orchid

    International Nuclear Information System (INIS)

    Suhaimi Musa; Sakinah Ariffin

    2005-01-01

    Studies on the induction of mutation in Dendrobium orchid at MINT has produced a number of new orchid mutant cultivars. Tissue culture techniques on orchid seeds and meristem cloning are employed in preparing the samples for the mutation induction. Solid medium based on the Murashige and Skoog (1962) and liquid medium based on Vacin and Went (1949) were found to be suitable in producing protocorm like bodies (PLBs) that are required for the irradiation treatment. (Author)

  14. [Standard sample preparation method for quick determination of trace elements in plastic].

    Science.gov (United States)

    Yao, Wen-Qing; Zong, Rui-Long; Zhu, Yong-Fa

    2011-08-01

    Reference sample was prepared by masterbatch method, containing heavy metals with known concentration of electronic information products (plastic), the repeatability and precision were determined, and reference sample preparation procedures were established. X-Ray fluorescence spectroscopy (XRF) analysis method was used to determine the repeatability and uncertainty in the analysis of the sample of heavy metals and bromine element. The working curve and the metrical methods for the reference sample were carried out. The results showed that the use of the method in the 200-2000 mg x kg(-1) concentration range for Hg, Pb, Cr and Br elements, and in the 20-200 mg x kg(-1) range for Cd elements, exhibited a very good linear relationship, and the repeatability of analysis methods for six times is good. In testing the circuit board ICB288G and ICB288 from the Mitsubishi Heavy Industry Company, results agreed with the recommended values.

  15. Cytotoxicity of Light-Cured Dental Materials according to Different Sample Preparation Methods

    Directory of Open Access Journals (Sweden)

    Myung-Jin Lee

    2017-03-01

    Full Text Available Dental light-cured resins can undergo different degrees of polymerization when applied in vivo. When polymerization is incomplete, toxic monomers may be released into the oral cavity. The present study assessed the cytotoxicity of different materials, using sample preparation methods that mirror clinical conditions. Composite and bonding resins were used and divided into four groups according to sample preparation method: uncured; directly cured samples, which were cured after being placed on solidified agar; post-cured samples were polymerized before being placed on agar; and “removed unreacted layer” samples had their oxygen-inhibition layer removed after polymerization. Cytotoxicity was evaluated using an agar diffusion test, MTT assay, and confocal microscopy. Uncured samples were the most cytotoxic, while removed unreacted layer samples were the least cytotoxic (p < 0.05. In the MTT assay, cell viability increased significantly in every group as the concentration of the extracts decreased (p < 0.05. Extracts from post-cured and removed unreacted layer samples of bonding resin were less toxic than post-cured and removed unreacted layer samples of composite resin. Removal of the oxygen-inhibition layer resulted in the lowest cytotoxicity. Clinicians should remove unreacted monomers on the resin surface immediately after restoring teeth with light-curing resin to improve the restoration biocompatibility.

  16. Recent advances in sample preparation techniques and methods of sulfonamides detection - A review.

    Science.gov (United States)

    Dmitrienko, Stanislava G; Kochuk, Elena V; Apyari, Vladimir V; Tolmacheva, Veronika V; Zolotov, Yury A

    2014-11-19

    Sulfonamides (SAs) have been the most widely used antimicrobial drugs for more than 70 years, and their residues in foodstuffs and environmental samples pose serious health hazards. For this reason, sensitive and specific methods for the quantification of these compounds in numerous matrices have been developed. This review intends to provide an updated overview of the recent trends over the past five years in sample preparation techniques and methods for detecting SAs. Examples of the sample preparation techniques, including liquid-liquid and solid-phase extraction, dispersive liquid-liquid microextraction and QuEChERS, are given. Different methods of detecting the SAs present in food and feed and in environmental, pharmaceutical and biological samples are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Electrodeposition as a sample preparation technique for TXRF analysis

    International Nuclear Information System (INIS)

    Griesel, S.; Reus, U.; Prange, A.

    2000-01-01

    TXRF analysis of trace elements at concentrations in the μg/L range and below in high salt matrices normally requires a number of sample preparation steps that include separation of the salt matrix and preconcentration of the trace elements. A neat approach which allows samples to be prepared straightforwardly in a single step involves the application of electrochemical deposition using the TXRF sample support itself as an electrode. For this work a common three-electrode arrangement (radiometer analytical) with a rotating disc electrode as the working electrode, as is frequently employed in voltametric analysis, has been used. A special electrode tip has been constructed as a holder for the sample carrier which consists of polished glassy carbon. This material has been proven to be suitable for both its electrical and chemical properties. Measurements of the trace elements were performed using the ATOMIKA 8030C TXRF spectrometer, with the option of variable incident angles. In first experiments an artificial sea water matrix containing various trace elements in the μg/L range has been used. Elements such as Cr, Mn, Fe, Co, Ni, Cu, Zn, Ag, Cd, Hg, and Pb deposited on glassy carbon carriers. The deposition can be optimized by controlling the potential of the working electrode with respect to the reference electrode. Metal ions with a suitable standard potential are reduced to the metallic state and plated onto the electrode surface. When deposition is finished the sample carrier is demounted, rinsed with ultra-pure water and measured directly. Deposition yields for the elements under investigation are quite similar, and with an appropriate choice of the reference element, quantification can be achieved directly by internal standardization. The influence of parameters such as time, pH value, and trace element concentration on the deposition yield has been examined, and the results will be presented along with reproducibility studies. (author)

  18. Guidance document for preparing water sampling and analysis plans for UMTRA Project sites. Revision 1

    International Nuclear Information System (INIS)

    1995-09-01

    A water sampling and analysis plan (WSAP) is prepared for each Uranium Mill Tailings Remedial Action (UMTRA) Project site to provide the rationale for routine ground water sampling at disposal sites and former processing sites. The WSAP identifies and justifies the sampling locations, analytical parameters, detection limits, and sampling frequency for the routine ground water monitoring stations at each site. This guidance document has been prepared by the Technical Assistance Contractor (TAC) for the US Department of Energy (DOE). Its purpose is to provide a consistent technical approach for sampling and monitoring activities performed under the WSAP and to provide a consistent format for the WSAP documents. It is designed for use by the TAC in preparing WSAPs and by the DOE, US Nuclear Regulatory Commission, state and tribal agencies, other regulatory agencies, and the public in evaluating the content of WSAPS

  19. Sample preparation for large-scale bioanalytical studies based on liquid chromatographic techniques.

    Science.gov (United States)

    Medvedovici, Andrei; Bacalum, Elena; David, Victor

    2018-01-01

    Quality of the analytical data obtained for large-scale and long term bioanalytical studies based on liquid chromatography depends on a number of experimental factors including the choice of sample preparation method. This review discusses this tedious part of bioanalytical studies, applied to large-scale samples and using liquid chromatography coupled with different detector types as core analytical technique. The main sample preparation methods included in this paper are protein precipitation, liquid-liquid extraction, solid-phase extraction, derivatization and their versions. They are discussed by analytical performances, fields of applications, advantages and disadvantages. The cited literature covers mainly the analytical achievements during the last decade, although several previous papers became more valuable in time and they are included in this review. Copyright © 2017 John Wiley & Sons, Ltd.

  20. Sample Preparation and Identification of Biological, Chemical and Mid-Spectrum Agents

    National Research Council Canada - National Science Library

    Hancock, J. R; Dragon, D. C

    2005-01-01

    A general survey of sample preparation and identification techniques for biological, chemical and mid-spectrum agents was conducted as part of Canada's contribution to a joint NATO Allied Engineering Publication (AEP) handbook...

  1. Advantages of automation in plasma sample preparation prior to HPLC/MS/MS quantification: application to the determination of cilazapril and cilazaprilat in a bioequivalence study.

    Science.gov (United States)

    Kolocouri, Filomila; Dotsikas, Yannis; Apostolou, Constantinos; Kousoulos, Constantinos; Soumelas, Georgios-Stefanos; Loukas, Yannis L

    2011-01-01

    An HPLC/MS/MS method characterized by complete automation and high throughput was developed for the determination of cilazapril and its active metabolite cilazaprilat in human plasma. All sample preparation and analysis steps were performed by using 2.2 mL 96 deep-well plates, while robotic liquid handling workstations were utilized for all liquid transfer steps, including liquid-liquid extraction. The whole procedure was very fast compared to a manual procedure with vials and no automation. The method also had a very short chromatographic run time of 1.5 min. Sample analysis was performed by RP-HPLC/MS/MS with positive electrospray ionization using multiple reaction monitoring. The calibration curve was linear in the range of 0.500-300 and 0.250-150 ng/mL for cilazapril and cilazaprilat, respectively. The proposed method was fully validated and proved to be selective, accurate, precise, reproducible, and suitable for the determination of cilazapril and cilazaprilat in human plasma. Therefore, it was applied to a bioequivalence study after per os administration of 2.5 mg tablet formulations of cilazapril.

  2. Bovine liver sample preparation and micro-homogeneity study for Cu and Zn determination by solid sampling electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Nomura, Cassiana S.; Silva, Cintia S.; Nogueira, Ana R.A.; Oliveira, Pedro V.

    2005-01-01

    This work describes a systematic study for the bovine liver sample preparation for Cu and Zn determination by solid sampling electrothermal atomic absorption spectrometry. The main parameters investigated were sample drying, grinding process, particle size, sample size, microsample homogeneity, and their relationship with the precision and accuracy of the method. A bovine liver sample was prepared using different drying procedures: (1) freeze drying, and (2) drying in a household microwave oven followed by drying in a stove at 60 deg. C until constant mass. Ball and cryogenic mills were used for grinding. Less sensitive wavelengths for Cu (216.5 nm) and Zn (307.6 nm), and Zeeman-based three-field background correction for Cu were used to diminish the sensitivities. The pyrolysis and atomization temperatures adopted were 1000 deg. C and 2300 deg. C for Cu, and 700 deg. C and 1700 deg. C for Zn, respectively. For both elements, it was possible to calibrate the spectrometer with aqueous solutions. The use of 250 μg of W + 200 μg of Rh as permanent chemical modifier was imperative for Zn. Under these conditions, the characteristic mass and detection limit were 1.4 ng and 1.6 ng for Cu, and 2.8 ng and 1.3 ng for Zn, respectively. The results showed good agreement (95% confidence level) for homogeneity of the entire material (> 200 mg) when the sample was dried in microwave/stove and ground in a cryogenic mill. The microsample homogeneity study showed that Zn is more dependent on the sample pretreatment than Cu. The bovine liver sample prepared in microwave/stove and ground in a cryogenic mill presented results with the lowest relative standard deviation for Cu than Zn. Good accuracy and precision were observed for bovine liver masses higher than 40 μg for Cu and 30 μg for Zn. The concentrations of Cu and Zn in the prepared bovine liver sample were 223 mg kg - 1 and 128 mg kg - 1 , respectively. The relative standard deviations were lower than 6% (n = 5). The

  3. Sample preparation: a critical step in the analysis of cholesterol oxidation products.

    Science.gov (United States)

    Georgiou, Christiana A; Constantinou, Michalis S; Kapnissi-Christodoulou, Constantina P

    2014-02-15

    In recent years, cholesterol oxidation products (COPs) have drawn scientific interest, particularly due to their implications on human health. A big number of these compounds have been demonstrated to be cytotoxic, mutagenic, and carcinogenic. The main source of COPs is through diet, and particularly from the consumption of cholesterol-rich foods. This raises questions about the safety of consumers, and it suggests the necessity for the development of a sensitive and a reliable analytical method in order to identify and quantify these components in food samples. Sample preparation is a necessary step in the analysis of COPs in order to eliminate interferences and increase sensitivity. Numerous publications have, over the years, reported the use of different methods for the extraction and purification of COPs. However, no method has, so far, been established as a routine method for the analysis of COPs in foods. Therefore, it was considered important to overview different sample preparation procedures and evaluate the different preparative parameters, such as time of saponification, the type of organic solvents for fat extraction, the stationary phase in solid phase extraction, etc., according to recovery, precision and simplicity. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Preparation of solid-state samples of a transition metal coordination compound for synchrotron radiation photoemission studies

    CERN Document Server

    Crotti, C; Celestino, T; Fontana, S

    2003-01-01

    The aim of this research was to identify a sample preparation method suitable for the study of transition metal complexes by photoemission spectroscopy with synchrotron radiation as the X-ray source, even in the case where the compound is not evaporable. Solid-phase samples of W(CO) sub 4 (dppe) [dppe=1,2-bis(diphenylphosphino)ethane] were prepared according to different methods and their synchrotron radiation XPS spectra measured. The spectra acquired from samples prepared by spin coating show core level peaks only slightly broader than the spectrum recorded from UHV evaporated samples. Moreover, for these samples the reproducibility of the binding energy values is excellent. The dependence of the spin coating technique on parameters such as solvent and solution concentration, spinning speed and support material was studied. The same preparation method also allowed the acquisition of valence band spectra, the main peaks of which were clearly resolved. The results suggest that use of the spin coating techniqu...

  5. Microfluidic devices for sample preparation and rapid detection of foodborne pathogens

    DEFF Research Database (Denmark)

    Kant, Krishna; Shahbazi, Mohammad-Ali; Dave, Vivek Priy

    2018-01-01

    and improve the limit of detections. Integration of pathogen capturing bio-receptors on microfluidic devices is a crucial step, which can facilitate recognition abilities in harsh chemical and physical conditions, offering a great commercial benefit to the food-manufacturing sector. This article reviews...... diagnosis competences. This has prompted researchers to call the current status of detection approaches into question and leverage new technologies for superior pathogen sensing outcomes. Novel strategies mainly rely on incorporating all the steps from sample preparation to detection in miniaturized devices...... recent advances in current state-of-the-art of sample preparation and concentration from food matrices with focus on bacterial capturing methods and sensing technologies, along with their advantages and limitations when integrated into microfluidic devices for online rapid detection of pathogens in foods...

  6. Sample preparation method for the combined extraction of ethyl glucuronide and drugs of abuse in hair.

    Science.gov (United States)

    Meier, Ulf; Briellmann, Thomas; Scheurer, Eva; Dussy, Franz

    2018-04-01

    Often in hair analysis, a small hair sample is available while the analysis of a multitude of structurally diverse substances with different concentration ranges is demanded. The analysis of the different substances often requires different sample preparation methods, increasing the amount of required hair sample. When segmental hair analysis is necessary, the amount of hair sample needed is further increased. Therefore, the required sample amount for a full analysis can quickly exceed what is available. To combat this problem, a method for the combined hair sample preparation using a single extraction procedure for analysis of ethyl glucuronide with liquid chromatography-multistage fragmentation mass spectrometry/multiple reaction monitoring (LC-MS 3 /MRM) and common drugs of abuse with LC-MRM was developed. The combined sample preparation is achieved by separating ethyl glucuronide from the drugs of abuse into separate extracts by fractionation in the solid-phase extraction step during sample clean-up. A full validation for all substances for the parameters selectivity, linearity, limit of detection, limit of quantification, accuracy, precision, matrix effects, and recovery was successfully completed. The following drugs of abuse were included in the method: Amphetamine; methamphetamine; 3,4-methylenedioxy-N-methylamphetamine (MDMA); 3,4-methylenedioxyamphetamine (MDA); 3,4-methylenedioxy-N-ethylamphetamine (MDE); morphine; 6-monoacetylmorphine; codeine; acetylcodeine; cocaine; benzoylecgonine; norcocaine; cocaethylene; methadone; 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) and methylphenidate. In conclusion, as only 1 sample preparation is needed with 1 aliquot of hair, the presented sample preparation allows an optimal analysis of both ethyl glucuronide and of the drugs of abuse, even when the sample amount is a limiting factor. Copyright © 2017 John Wiley & Sons, Ltd.

  7. Study of sample preparation in the measurement of 36Ar(n, p)36Cl reaction cross section

    International Nuclear Information System (INIS)

    Jiang Songsheng; Hemick, T.K.

    1992-01-01

    The preparation of enriched 36 Ar gas samples and 36 Cl samples for the use in the AMS measurement of 36 Ar(n, p) 36 Cl reaction cross section was described. The 36 Ar samples prepared had the volumes of about 0.4 ml and the weights of about 0.5 mg. The uncertainty in atomic numbers of 36 Ar was (0.3∼0.4)%. The reaction product, 36 Cl, in the 36 Ar was collected and the AgCl samples were prepared

  8. Dynamic Headspace Sampling as an Initial Step for Sample Preparation in Chromatographic Analysis.

    Science.gov (United States)

    Wojnowski, Wojciech; Majchrzak, Tomasz; Dymerski, Tomasz; Gębicki, Jacek; Namieśnik, Jacek

    2017-11-01

    This work represents a brief summary of the use of dynamic headspace (DHS) as a technique for sample preparation in chromatographic analysis. Despite numerous developments in the area of analyte isolation and enrichment, DHS remains one of the fundamental methods used with GC. In our opinion, interest in this technique will not diminish significantly because it conforms to stipulations of green analytical chemistry. Moreover, DHS fulfills the need for methods that facilitate detection and determination of analytes present at ultratrace levels in complex matrixes. The main focus of this work was placed on the theoretical fundamentals of this method. Also described herein were DHS development, the advantages and disadvantages of this technique compared with other headspace sampling techniques, and selected examples of its applications in food and environmental analyses.

  9. Ultrasonic assisted extraction - an alternative for sample preparation (M4)

    International Nuclear Information System (INIS)

    Santos Junior, P.; Barbosa Junior, F.; Krug, F.J.; Trevizan, L.C.; Nobrega, J.A.

    2002-01-01

    Full text: In the last years the ultrasound assisted metal extraction has been frequency proposed as a simple and inexpensive alternative for sample preparation of biological and inorganic samples. The extraction effect is considered as being caused by acoustic cavitation, that is, bubble formation and subsequent disruptive action. The collapse of bubbles created by sonication of solutions results in the generation of extremely high local temperature and pressure gradients, which may be regarded as localized 'hot spots'. On a timescale of about 10 -10 s, effective local pressures and temperature of about 10 5 atm and about 5000 K, respectively, are generated under sonochemical conditions. Usually, this method uses a diluted acid medium decreasing blank values and reducing both reagents and time consumption compared to traditional wet digestion systems using conductive or microwave-assisted heating. Furthermore, sonication can also allow the preparation of samples directly within the sample container, thereby preventing sample losses and minimizing sample contamination. Although some controversial results concerning metals extraction behavior have been reported, they could be explained by analyte-matrix interaction and the ability of the ultrasonic processor to generate ultrasound (i.e. the use of an ultrasonic bath or an ultrasonic probe at different power, frequency, and amplitude). This contribution presents a review of ultrasound assisted metal extraction and recent performance data obtained in our laboratory for determination of elements in biological materials, soils and sediments by ICP-OES and ETAAS. The effect of extraction parameters, such as type and concentration of the leaching solution, sonication time and performance of ultrasonic processor (bath or probe) will be presented. (author)

  10. Homogeneous immunosubtraction integrated with sample preparation is enabled by a microfluidic format

    Science.gov (United States)

    Apori, Akwasi A.; Herr, Amy E.

    2011-01-01

    Immunosubtraction is a powerful and resource-intensive laboratory medicine assay that reports both protein mobility and binding specificity. To expedite and automate this electrophoretic assay, we report on advances to the electrophoretic immunosubtraction assay by introducing a homogeneous, not heterogeneous, format with integrated sample preparation. To accomplish homogeneous immunosubtraction, a step-decrease in separation matrix pore-size at the head of a polyacrylamide gel electrophoresis (PAGE) separation channel enables ‘subtraction’ of target analyte when capture antibody is present (as the large immune-complex is excluded from PAGE), but no subtraction when capture antibody is absent. Inclusion of sample preparation functionality via small pore size polyacrylamide membranes is also key to automated operation (i.e., sample enrichment, fluorescence sample labeling, and mixing of sample with free capture antibody). Homogenous sample preparation and assay operation allows on-the-fly, integrated subtraction of one to multiple protein targets and reuse of each device. Optimization of the assay is detailed which allowed for ~95% subtraction of target with 20% non-specific extraction of large species at the optimal antibody-antigen ratio, providing conditions needed for selective target identification. We demonstrate the assay on putative markers of injury and inflammation in cerebrospinal fluid (CSF), an emerging area of diagnostics research, by rapidly reporting protein mobility and binding specificity within the sample matrix. We simultaneously detect S100B and C-reactive protein, suspected biomarkers for traumatic brain injury (TBI), in ~2 min. Lastly, we demonstrate S100B detection (65 nM) in raw human CSF with a lower limit of detection of ~3.25 nM, within the clinically relevant concentration range for detecting TBI in CSF. Beyond the novel CSF assay introduced here, a fully automated immunosubtraction assay would impact a spectrum of routine but labor

  11. The effects of acid treatment and sample preparation on 40Ar/39Ar ages

    Science.gov (United States)

    Morgan, L. E.; Davidheiser, B.; Kuiper, K.; Wijbrans, J. R.

    2011-12-01

    Practitioners of K-Ar and 40Ar/39Ar geochronology regularly use dilute acids (typically 5-10% hydrofluoric acid (HF)) to clean mineral grains prior to irradiation (in the case of 40Ar/39Ar), and analysis (e.g. Evernden and Curtis, 1965; Dalrymple, 1967). This treatment has been shown to reduce contamination from atmospheric Ar, which consists largely of 40Ar and thus must be differentiated from radiogenic 40Ar* (Evernden and Curtis, 1965). Acid treatments can also remove fine grained material attached to mineral grains, such as glass shards or devitrified glass, which can affect analyses and is difficult to remove by other means (Evernden and Curtis, 1965). Such treatments were originally examined for their efficacy in reducing atmospheric argon contamination (Dalrymple, 1967) but were not assessed for the possibility of leaching Ar* or K differentially, which would affect both K-Ar and 40Ar/39Ar ages. Indeed, Evernden and Curtis (1965) state that they are simply removing the "outer portions of the crystals" and apparently do not account for the potential for leaching of 40Ar* or K from the mass of their host mineral. Moreover, the capabilities of the K-Ar system in the 1960s was limited to a precision of ca. 3-4% on samples of 1-3 Ma (Cox and Dalrymple, 1967). Effects of smaller magnitude could not have been detected at the time. As the developments of the 40Ar/39Ar system and modern mass spectrometer technology have allowed for precision to approach 0.1%, the potential effects of acid treatment during sample preparation warrant revisiting. Additionally, the use of Calgon for sample disintegration has not previously been quantitatively assessed but is used extensively in some laboratories. Here we present a series of experiments from co-irradiated Fish Canyon sanidine (FCs) and Mes-4 (Kuiper et al., 2008). FCs is used as the mineral standard following standard procedures. Mes-4 splits were treated with H2O (10 minutes, ultrasonic), Calgon (10%, overnight at 50

  12. Recent Trends in Microextraction Techniques Employed in Analytical and Bioanalytical Sample Preparation

    Directory of Open Access Journals (Sweden)

    Abuzar Kabir

    2017-12-01

    Full Text Available Sample preparation has been recognized as a major step in the chemical analysis workflow. As such, substantial efforts have been made in recent years to simplify the overall sample preparation process. Major focusses of these efforts have included miniaturization of the extraction device; minimizing/eliminating toxic and hazardous organic solvent consumption; eliminating sample pre-treatment and post-treatment steps; reducing the sample volume requirement; reducing extraction equilibrium time, maximizing extraction efficiency etc. All these improved attributes are congruent with the Green Analytical Chemistry (GAC principles. Classical sample preparation techniques such as solid phase extraction (SPE and liquid-liquid extraction (LLE are being rapidly replaced with emerging miniaturized and environmentally friendly techniques such as Solid Phase Micro Extraction (SPME, Stir bar Sorptive Extraction (SBSE, Micro Extraction by Packed Sorbent (MEPS, Fabric Phase Sorptive Extraction (FPSE, and Dispersive Liquid-Liquid Micro Extraction (DLLME. In addition to the development of many new generic extraction sorbents in recent years, a large number of molecularly imprinted polymers (MIPs created using different template molecules have also enriched the large cache of microextraction sorbents. Application of nanoparticles as high-performance extraction sorbents has undoubtedly elevated the extraction efficiency and method sensitivity of modern chromatographic analyses to a new level. Combining magnetic nanoparticles with many microextraction sorbents has opened up new possibilities to extract target analytes from sample matrices containing high volumes of matrix interferents. The aim of the current review is to critically audit the progress of microextraction techniques in recent years, which has indisputably transformed the analytical chemistry practices, from biological and therapeutic drug monitoring to the environmental field; from foods to phyto

  13. Effect of sample preparation methods on photometric determination of the tellurium and cobalt content in the samples of copper concentrates

    Directory of Open Access Journals (Sweden)

    Viktoriya Butenko

    2016-03-01

    Full Text Available Methods of determination of cobalt and nickel in copper concentrates currently used in factory laboratories are very labor intensive and time consuming. The limiting stage of the analysis is preliminary chemical sample preparation. Carrying out the decomposition process of industrial samples with concentrated mineral acids in open systems does not allow to improve the metrological characteristics of the methods, for this reason improvement the methods of sample preparation is quite relevant and has a practical interest. The work was dedicated to the determination of the optimal conditions of preliminary chemical preparation of copper concentrate samples for the subsequent determination of cobalt and tellurium in the obtained solution using tellurium-spectrophotometric method. Decomposition of the samples was carried out by acid dissolving in individual mineral acids and their mixtures by heating in an open system as well as by using ultrasonification and microwave radiation in a closed system. In order to select the optimal conditions for the decomposition of the samples in a closed system the phase contact time and ultrasonic generator’s power were varied. Intensification of the processes of decomposition of copper concentrates with nitric acid (1:1, ultrasound and microwave radiation allowed to transfer quantitatively cobalt and tellurium into solution spending 20 and 30 min respectively. This reduced the amount of reactants used and improved the accuracy of determination by running the process in strictly identical conditions.

  14. Robotic sample preparation for radiochemical plutonium and americium analyses

    International Nuclear Information System (INIS)

    Stalnaker, N.; Beugelsdijk, T.; Thurston, A.; Quintana, J.

    1985-01-01

    A Zymate robotic system has been assembled and programmed to prepare samples for plutonium and americium analyses by radioactivity counting. The system performs two procedures: a simple dilution procedure and a TTA (xylene) extraction of plutonium. To perform the procedures, the robotic system executes 11 unit operations such as weighing, pipetting, mixing, etc. Approximately 150 programs, which require 64 kilobytes of memory, control the system. The system is now being tested with high-purity plutonium metal and plutonium oxide samples. Our studies indicate that the system can give results that agree within 5% at the 95% confidence level with determinations performed manually. 1 ref., 1 fig., 1 tab

  15. Sample preparation composite and replicate strategy case studies for assay of solid oral drug products.

    Science.gov (United States)

    Nickerson, Beverly; Harrington, Brent; Li, Fasheng; Guo, Michele Xuemei

    2017-11-30

    Drug product assay is one of several tests required for new drug products to ensure the quality of the product at release and throughout the life cycle of the product. Drug product assay testing is typically performed by preparing a composite sample of multiple dosage units to obtain an assay value representative of the batch. In some cases replicate composite samples may be prepared and the reportable assay value is the average value of all the replicates. In previously published work by Harrington et al. (2014) [5], a sample preparation composite and replicate strategy for assay was developed to provide a systematic approach which accounts for variability due to the analytical method and dosage form with a standard error of the potency assay criteria based on compendia and regulatory requirements. In this work, this sample preparation composite and replicate strategy for assay is applied to several case studies to demonstrate the utility of this approach and its application at various stages of pharmaceutical drug product development. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Integrated Automation of High-Throughput Screening and Reverse Phase Protein Array Sample Preparation

    DEFF Research Database (Denmark)

    Pedersen, Marlene Lemvig; Block, Ines; List, Markus

    into automated robotic high-throughput screens, which allows subsequent protein quantification. In this integrated solution, samples are directly forwarded to automated cell lysate preparation and preparation of dilution series, including reformatting to a protein spotter-compatible format after the high......-throughput screening. Tracking of huge sample numbers and data analysis from a high-content screen to RPPAs is accomplished via MIRACLE, a custom made software suite developed by us. To this end, we demonstrate that the RPPAs generated in this manner deliver reliable protein readouts and that GAPDH and TFR levels can...

  17. Influence of rice sample preparation and milling procedures on milling quality appraisals

    Science.gov (United States)

    The objective of this research was to investigate the effect of sample preparation and milling procedure on milling quality appraisals of rough rice. Samples of freshly harvested medium-grain rice (M202) with different initial moisture contents (MCs) ranging from 20.2% to 25.1% (w.b.) were used for...

  18. Microextraction sample preparation techniques in biomedical analysis.

    Science.gov (United States)

    Szultka, Malgorzata; Pomastowski, Pawel; Railean-Plugaru, Viorica; Buszewski, Boguslaw

    2014-11-01

    Biologically active compounds are found in biological samples at relatively low concentration levels. The sample preparation of target compounds from biological, pharmaceutical, environmental, and food matrices is one of the most time-consuming steps in the analytical procedure. The microextraction techniques are dominant. Metabolomic studies also require application of proper analytical technique for the determination of endogenic metabolites present in biological matrix on trace concentration levels. Due to the reproducibility of data, precision, relatively low cost of the appropriate analysis, simplicity of the determination, and the possibility of direct combination of those techniques with other methods (combination types on-line and off-line), they have become the most widespread in routine determinations. Additionally, sample pretreatment procedures have to be more selective, cheap, quick, and environmentally friendly. This review summarizes the current achievements and applications of microextraction techniques. The main aim is to deal with the utilization of different types of sorbents for microextraction and emphasize the use of new synthesized sorbents as well as to bring together studies concerning the systematic approach to method development. This review is dedicated to the description of microextraction techniques and their application in biomedical analysis. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. New and conventional evaporative systems in concentrating nitrogen samples prior to isotope-ratio analysis

    International Nuclear Information System (INIS)

    Lober, R.W.; Reeder, J.D.; Porter, L.K.

    1987-01-01

    Studies were conducted to quantify and compare the efficiencies of various evaporative systems used in evaporating 15 N samples prior to mass spectrometric analysis. Two new forced-air systems were designed and compared with a conventional forced-air system and with an open-air dry bath technique for effectiveness in preventing atmospheric contamination of evaporating samples. The forced-air evaporative systems significantly reduced the time needed to evaporate samples as compared to the open-air dry bath technique; samples were evaporated to dryness in 2.5 h with the forced-air systems as compared to 8 to 10 h on the open-air dry bath. The effectiveness of a given forced-air system to prevent atmospheric contamination of evaporating samples was significantly affected by the flow rate of the air stream flowing over the samples. The average atmospheric contaminant N found in samples evaporated on the open-air dry bath was 0.3 μ N, indicating very low concentrations of atmospheric NH 3 during this study. However, in previous studies the authors have experienced significant contamination of 15 N samples evaporated on an open-air dry bath because the level of contaminant N in the laboratory atmosphere varied and could not be adequately controlled. Average cross-contaminant levels of 0.28, 0.20, and 1.01 μ of N were measured between samples evaporated on the open-air dry bath, the newly-designed forced-air system, and the conventional forced-air system, respectively. The cross-contamination level is significantly higher on the conventional forced-air system than on the other two systems, and could significantly alter the atom % 15 N of high-enriched, low [N] evaporating samples

  20. Notes on sample preparation of food: food of plant and animal origins, and daily meals

    International Nuclear Information System (INIS)

    Heilgeist, M.

    1992-01-01

    The procedure of food sample preparation to determine their specific radioactivity, analogous to chemical residue analysis, is laid down in the relevant sets of regulations. Several procedural steps of sample preparation of single food and composite food are dealt with. The sample size necessary for gamma spectroscopy and Sr-89/Sr-90 analysis, and the incineration step to enrich radionuclides are explained. Finally, enrichment by freeze drying of the high-volatile radionuclide I-131 is considered. (orig.) [de

  1. Sample collection and preparation of biofluids and extracts for gas chromatography-mass spectrometry.

    Science.gov (United States)

    Emwas, Abdul-Hamid M; Al-Talla, Zeyad A; Kharbatia, Najeh M

    2015-01-01

    To maximize the utility of gas chromatography-mass spectrometry (GC-MS) in metabonomics research, all stages of the experimental design should be standardized, including sample collection, storage, preparation, and sample separation. Moreover, the prerequisite for any GC-MS analysis is that a compound must be volatile and thermally stable if it is to be analyzed using this technique. Since many metabolites are nonvolatile and polar in nature, they are not readily amenable to analysis by GC-MS and require initial chemical derivatization of the polar functional groups in order to reduce the polarity and to increase the thermal stability and volatility of the analytes. In this chapter, an overview is presented of the optimum approach to sample collection, storage, and preparation for gas chromatography-mass spectrometry-based metabonomics with particular focus on urine samples as example of biofluids.

  2. Open focused microwave-assisted sample preparation for rapid total and mercury species determination in environmental solid samples

    OpenAIRE

    Tseng, C. M.; Garraud, H.; Amouroux, D.; Donard, O. F. X.; de Diego, A.

    1998-01-01

    This paper describes rapid, simple microwave-assisted leaching/ digestion procedures for total and mercury species determination in sediment samples and biomaterials. An open focused microwave system allowed the sample preparation time to be dramatically reduced to only 24 min when a power of 40-80 W was applied. Quantitative leaching of methylmercury from sediments by HNO3 solution and complete dissolution of biomaterials by an alkaline solution, such as 25% TMAH solution, were obtained. Met...

  3. Effect of method of sample preparation on ruminal in situ ...

    African Journals Online (AJOL)

    Midmar) was harvested at three and four weeks after cutting and fertilizing with 200 kg nitrogen (N)/ha. Freshly cut herbage was used to investigate the following four sample preparation methods. In trial 1, herbage was (1) chopped with a paper-cutting guillotine into 5-10 mm lengths, representing fresh (FR) herbage; ...

  4. Soybean and lactose in meat products and preparations sampled at retail

    Directory of Open Access Journals (Sweden)

    Filomena Piccolo

    2016-06-01

    Full Text Available Food allergies and intolerances have increased during the last decades and regulatory authorities have taken different measures to prevent and manage consumers’ adverse reactions, including correct labelling of foods. Aim of this work was to search for soybean and lactose in meat products and meat preparations taken from retail in some provinces of Campania Region (Southern Italy and to evaluate the food labels compliance with Regulation (EU n.1169/2011. Soybean and lactose were searched using commercial kits in n. 58 samples of meat products produced in or distributed by 19 establishments, and in n. 55 samples of meat products and n. 8 of meat preparations produced in 21 plants. All samples were selected on the basis of the absence of any information on the labels about the presence of the two searched allergens, with the exception of n. 5 samples tested for lactose. Traces of soybean were detected in 50 out of the 58 examined samples, at concentrations up to 0.93 mg kg–1. Only two samples contained levels above the detection limit of 0.31 mg kg–1. Lactose levels ranging from 0.11 to 2.95 g/100 g, i.e. above the detection limit, were found in all the tested samples (n. 63. The results of the present research underline the need for careful controls and planning by operators as part of the self-control plans, and deserve attention from the competent authorities considering not only the consumers’ health but also the great attention media pay to regulations providing consumers with information on food.

  5. Simplifying the Preparation of Pollen Grains for MALDI-TOF MS Classification

    Directory of Open Access Journals (Sweden)

    Franziska Lauer

    2017-03-01

    Full Text Available Matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF MS is a well-implemented analytical technique for the investigation of complex biological samples. In MS, the sample preparation strategy is decisive for the success of the measurements. Here, sample preparation processes and target materials for the investigation of different pollen grains are compared. A reduced and optimized sample preparation process prior to MALDI-TOF measurement is presented using conductive carbon tape as target. The application of conductive tape yields in enhanced absolute signal intensities and mass spectral pattern information, which leads to a clear separation in subsequent pattern analysis. The results will be used to improve the taxonomic differentiation and identification, and might be useful for the development of a simple routine method to identify pollen based on mass spectrometry.

  6. Influence of sample preparation on the microstructure of tooth enamel apatite

    Czech Academy of Sciences Publication Activity Database

    Kallistová, Anna; Skála, Roman; Horáček, I.; Miyajima, N.; Malíková, R.

    2015-01-01

    Roč. 48, č. 3 (2015), s. 763-768 ISSN 0021-8898 Institutional support: RVO:67985831 Keywords : X-ray powder diffraction * sample preparation * microstructure * dental hydroxyapatite Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 3.720, year: 2014

  7. Comparison of two sample preparation procedures for HPLC determination of ochratoxin A

    Directory of Open Access Journals (Sweden)

    Vuković Gorica L.

    2009-01-01

    Full Text Available In preparation of samples for chromatographic determination of ochratoxin A, two types of columns were used for sample cleanup (SPE and immunoaffinity columns. The first method consisted of liquid-liquid extraction with a mixture of chloroform and phosphoric acid, followed by ion-exchange cleanup on Waters Oasis MAX columns. The sec­ond method consisted of extraction with a mixture of water and methanol, followed by LCTech OtaCLEAN immunoaf­finity column cleanup. Recoveries of the methods were determined at three levels in three repetitions for maize flour, and they were 84% (%RSD = 19.2 for the first method of sample preparation and 101% (%RSD = 2.2 for the second method. Values of LOQ for OTA were 0.25 and 1.00 μg/kg for the IAC and SPE clean-up procedures, respectively. Both methods comply with present regulations, but the MAX sample clean-up procedure should be used as an alternative, since the immunoaffinity column clean-up procedure is characterized by better reproducibility, accuracy, and efficiency.

  8. An electrodeposition method for the preparation of actinides and Ra samples for α spectrometry

    International Nuclear Information System (INIS)

    Garcia-Tenorio, R.; Garcia-Leon, M.; Madurga, G.; Piazza, C.

    1986-01-01

    As it is confirmed in this work, electrodeposition of α radionuclides gives a simple method for preparing α samples of high spectrometric quality, compared to those prepared by evaporation. Then we give the methods for electrodepositon or α emitters use in our Department. Actinides α emitters are electroplated from a 1% H 2 SO 4 medium with a recovery of about 90%. The samples of Ra are prepared by electrodeposition from a HCl + CH 3 -COONH 4 medium at pH approx.= 5. In this case the recovery reaches a value that ranges from 70 to 90%. For these measurements a Si surface barrier detector has been used. Some of its features are discussed in the text. (author)

  9. On the preparation of as-produced and purified single-walled carbon nanotube samples for standardized X-ray diffraction characterization

    International Nuclear Information System (INIS)

    Allaf, Rula M.; Rivero, Iris V.; Spearman, Shayla S.; Hope-Weeks, Louisa J.

    2011-01-01

    The aim of this research was to specify proper sample conditioning for acquiring representative X-ray diffraction (XRD) profiles for single-walled carbon nanotube (SWCNT) samples. In doing so, a specimen preparation method for quantitative XRD characterization of as-produced and purified arc-discharge SWCNT samples has been identified. Series of powder XRD profiles were collected at different temperatures, states, and points of time to establish appropriate conditions for acquiring XRD profiles without inducing much change to the specimen. It was concluded that heating in the 300-450 deg. C range for 20 minutes, preferably vacuum-assisted, and then sealing the sample is an appropriate XRD specimen preparation technique for purified arc-discharge SWCNT samples, while raw samples do not require preconditioning for characterization. - Graphical Abstract: A sample preparation method for XRD characterization of as-produced and purified arc-discharge SWCNT samples is identified. The preparation technique seeks to acquire representative XRD profiles without inducing changes to the samples. Purified samples required 20 minutes of heating at (300-450)deg. C, while raw samples did not require preconditioning for characterization. Highlights: → Purification routines may induce adsorption onto the SWCNT samples. → Heating a SWCNT sample may result in material loss, desorption, and SWCNTs closing. → Raw arc-discharge samples do not require preparation for XRD characterization. → Heating is appropriate specimen preparation for purified and heat-treated samples. → XRD data fitting is required for structural analysis of SWCNT bundles.

  10. Validation of a fully automated robotic setup for preparation of whole blood samples for LC-MS toxicology analysis

    DEFF Research Database (Denmark)

    Andersen, David Wederkinck; Rasmussen, Brian; Linnet, Kristian

    2012-01-01

    A fully automated setup was developed for preparing whole blood samples using a Tecan Evo workstation. By integrating several add-ons to the robotic platform, the flexible setup was able to prepare samples from sample tubes to a 96-well sample plate ready for injection on liquid chromatography...

  11. Sampling, feasibility, and priors in Bayesian estimation

    OpenAIRE

    Chorin, Alexandre J.; Lu, Fei; Miller, Robert N.; Morzfeld, Matthias; Tu, Xuemin

    2015-01-01

    Importance sampling algorithms are discussed in detail, with an emphasis on implicit sampling, and applied to data assimilation via particle filters. Implicit sampling makes it possible to use the data to find high-probability samples at relatively low cost, making the assimilation more efficient. A new analysis of the feasibility of data assimilation is presented, showing in detail why feasibility depends on the Frobenius norm of the covariance matrix of the noise and not on the number of va...

  12. A sample preparation method for recovering suppressed analyte ions in MALDI TOF MS

    NARCIS (Netherlands)

    Lou, X.; Waal, de B.F.M.; Milroy, L.G.; Dongen, van J.L.J.

    2015-01-01

    In matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF MS), analyte signals can be substantially suppressed by other compounds in the sample. In this technical note, we describe a modified thin-layer sample preparation method that significantly reduces the analyte

  13. Evaluation of sample preparation protocols for spider venom profiling by MALDI-TOF MS.

    Science.gov (United States)

    Bočánek, Ondřej; Šedo, Ondrej; Pekár, Stano; Zdráhal, Zbyněk

    2017-07-01

    Spider venoms are highly complex mixtures containing biologically active substances with potential for use in biotechnology or pharmacology. Fingerprinting of venoms by Matrix-Assisted Laser Desorption-Ionization - Time of Flight Mass Spectrometry (MALDI-TOF MS) is a thriving technology, enabling the rapid detection of peptide/protein components that can provide comparative information. In this study, we evaluated the effects of sample preparation procedures on MALDI-TOF mass spectral quality to establish a protocol providing the most reliable analytical outputs. We adopted initial sample preparation conditions from studies already published in this field. Three different MALDI matrixes, three matrix solvents, two sample deposition methods, and different acid concentrations were tested. As a model sample, venom from Brachypelma albopilosa was used. The mass spectra were evaluated on the basis of absolute and relative signal intensities, and signal resolution. By conducting three series of analyses at three weekly intervals, the reproducibility of the mass spectra were assessed as a crucial factor in the selection for optimum conditions. A sample preparation protocol based on the use of an HCCA matrix dissolved in 50% acetonitrile with 2.5% TFA deposited onto the target by the dried-droplet method was found to provide the best results in terms of information yield and repeatability. We propose that this protocol should be followed as a standard procedure, enabling the comparative assessment of MALDI-TOF MS spider venom fingerprints. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. In vitro fermentability of differently digested resistant starch preparations

    NARCIS (Netherlands)

    Fässler, C.; Arrigoni, E.; Venema, K.; Brouns, F.; Amadò, R.

    2006-01-01

    The in vitro fermentability of two resistant starch preparations type 2 (RS2) and type 3 (RS3) was investigated using human colonic microbiota. Prior to the fermentation experiments, samples were digested using two in vitro models, a batch (ba) and a dynamic (dy), as well as an in vivo method (il)

  15. Challenges of sample preparation for cross sectional EBSD analysis of electrodeposited nickel films

    DEFF Research Database (Denmark)

    Alimadadi, Hossein; Pantleon, Karen

    2009-01-01

    Thorough microstructure and crystallographic orientation analysis of thin films by means of electron backscatter diffraction requires cross section preparation of the film-substrate compound. During careful preparation, changes of the rather non-stable as-deposited microstructure must be avoided....... Different procedures for sample preparation including mechanical grinding and polishing, electropolishing and focused ion beam milling have been applied to a nickel film electrodeposited on top of an amorphous Ni-P layer on a Cu-substrate. Reliable EBSD analysis of the whole cross section can be obtained...

  16. Transmission Electron Microscopy (TEM) Sample Preparation of Si(1-x)Gex in c-Plane Sapphire Substrate

    Science.gov (United States)

    Kim, Hyun Jung; Choi, Sang H.; Bae, Hyung-Bin; Lee, Tae Woo

    2012-01-01

    The National Aeronautics and Space Administration-invented X-ray diffraction (XRD) methods, including the total defect density measurement method and the spatial wafer mapping method, have confirmed super hetero epitaxy growth for rhombohedral single crystalline silicon germanium (Si1-xGex) on a c-plane sapphire substrate. However, the XRD method cannot observe the surface morphology or roughness because of the method s limited resolution. Therefore the authors used transmission electron microscopy (TEM) with samples prepared in two ways, the focused ion beam (FIB) method and the tripod method to study the structure between Si1-xGex and sapphire substrate and Si1?xGex itself. The sample preparation for TEM should be as fast as possible so that the sample should contain few or no artifacts induced by the preparation. The standard sample preparation method of mechanical polishing often requires a relatively long ion milling time (several hours), which increases the probability of inducing defects into the sample. The TEM sampling of the Si1-xGex on sapphire is also difficult because of the sapphire s high hardness and mechanical instability. The FIB method and the tripod method eliminate both problems when performing a cross-section TEM sampling of Si1-xGex on c-plane sapphire, which shows the surface morphology, the interface between film and substrate, and the crystal structure of the film. This paper explains the FIB sampling method and the tripod sampling method, and why sampling Si1-xGex, on a sapphire substrate with TEM, is necessary.

  17. Molecularly imprinted polymers for sample preparation and biosensing in food analysis: Progress and perspectives

    DEFF Research Database (Denmark)

    Ashley, Jon; Shahbazi, Mohammad-Ali; Kant, Krishna

    2017-01-01

    Molecularly imprinted polymers (MIPs) are biomimetics which can selectively bind to analytes of interest. One of the most interesting areas where MIPs have shown the biggest potential is food analysis. MIPs have found use as sorbents in sample preparation attributed to the high selectivity and high...... the imprinting methods which are applicable for imprinting food templates, summarize the recent progress in using MIPs for preparing and analysing food samples, and discuss the current limitations in the commercialisation of MIPs technology. Finally, future perspectives will be given....

  18. An On-Target Desalting and Concentration Sample Preparation Protocol for MALDI-MS and MS/MS Analysis

    DEFF Research Database (Denmark)

    Zhang, Xumin; Wang, Quanhui; Lou, Xiaomin

    2012-01-01

    2DE coupled with MALDI-MS is one of the most widely used and powerful analytic technologies in proteomics study. The MALDI sample preparation method has been developed and optimized towards the combination of simplicity, sample-cleaning, and sample concentration since its introduction. Here we...... present a protocol of the so-called Sample loading, Matrix loading, and on-target Wash (SMW) method which fulfills the three criteria by taking advantage of the AnchorChip™ targets. Our method is extremely simple and no pre-desalting or concentration is needed when dealing with samples prepared from 2DE...

  19. Effects of model complexity and priors on estimation using sequential importance sampling/resampling for species conservation

    Science.gov (United States)

    Dunham, Kylee; Grand, James B.

    2016-01-01

    We examined the effects of complexity and priors on the accuracy of models used to estimate ecological and observational processes, and to make predictions regarding population size and structure. State-space models are useful for estimating complex, unobservable population processes and making predictions about future populations based on limited data. To better understand the utility of state space models in evaluating population dynamics, we used them in a Bayesian framework and compared the accuracy of models with differing complexity, with and without informative priors using sequential importance sampling/resampling (SISR). Count data were simulated for 25 years using known parameters and observation process for each model. We used kernel smoothing to reduce the effect of particle depletion, which is common when estimating both states and parameters with SISR. Models using informative priors estimated parameter values and population size with greater accuracy than their non-informative counterparts. While the estimates of population size and trend did not suffer greatly in models using non-informative priors, the algorithm was unable to accurately estimate demographic parameters. This model framework provides reasonable estimates of population size when little to no information is available; however, when information on some vital rates is available, SISR can be used to obtain more precise estimates of population size and process. Incorporating model complexity such as that required by structured populations with stage-specific vital rates affects precision and accuracy when estimating latent population variables and predicting population dynamics. These results are important to consider when designing monitoring programs and conservation efforts requiring management of specific population segments.

  20. A comparison of sample preparation strategies for biological tissues and subsequent trace element analysis using LA-ICP-MS.

    Science.gov (United States)

    Bonta, Maximilian; Török, Szilvia; Hegedus, Balazs; Döme, Balazs; Limbeck, Andreas

    2017-03-01

    Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) is one of the most commonly applied methods for lateral trace element distribution analysis in medical studies. Many improvements of the technique regarding quantification and achievable lateral resolution have been achieved in the last years. Nevertheless, sample preparation is also of major importance and the optimal sample preparation strategy still has not been defined. While conventional histology knows a number of sample pre-treatment strategies, little is known about the effect of these approaches on the lateral distributions of elements and/or their quantities in tissues. The technique of formalin fixation and paraffin embedding (FFPE) has emerged as the gold standard in tissue preparation. However, the potential use for elemental distribution studies is questionable due to a large number of sample preparation steps. In this work, LA-ICP-MS was used to examine the applicability of the FFPE sample preparation approach for elemental distribution studies. Qualitative elemental distributions as well as quantitative concentrations in cryo-cut tissues as well as FFPE samples were compared. Results showed that some metals (especially Na and K) are severely affected by the FFPE process, whereas others (e.g., Mn, Ni) are less influenced. Based on these results, a general recommendation can be given: FFPE samples are completely unsuitable for the analysis of alkaline metals. When analyzing transition metals, FFPE samples can give comparable results to snap-frozen tissues. Graphical abstract Sample preparation strategies for biological tissues are compared with regard to the elemental distributions and average trace element concentrations.

  1. Freezing fecal samples prior to DNA extraction affects the Firmicutes to Bacteroidetes ratio determined by downstream quantitative PCR analysis

    DEFF Research Database (Denmark)

    Bahl, Martin Iain; Bergström, Anders; Licht, Tine Rask

    2012-01-01

    Freezing stool samples prior to DNA extraction and downstream analysis is widely used in metagenomic studies of the human microbiota but may affect the inferred community composition. In this study, DNA was extracted either directly or following freeze storage of three homogenized human fecal...

  2. Freezing fecal samples prior to DNA extraction affects the Firmicutes to Bacteroidetes ratio determined by downstream quantitative PCR analysis

    DEFF Research Database (Denmark)

    Bahl, Martin Iain; Bergström, Anders; Licht, Tine Rask

    Freezing stool samples prior to DNA extraction and downstream analysis is widely used in metagenomic studies of the human microbiota but may affect the inferred community composition. In this study DNA was extracted either directly or following freeze storage of three homogenized human fecal...

  3. Atomic absorption determination of metals in soils using ultrasonic sample preparation

    International Nuclear Information System (INIS)

    Chmilenko, F.A.; Smityuk, N.M.; Baklanov, A.N.

    2002-01-01

    It was shown that ultrasonic treatment accelerates sample preparation of soil extracts from chernozem into different solvents by a factor of 6 to 60. These extracts are used for the atomic absorption determination of soluble species of Cd, Co, Cr, Cu, Ni, Pb, and Zn. The optimum ultrasound parameters (frequency, intensity, and treatment time) were found for preparing soil extracts containing analytes in concentrations required in agrochemical procedures. Different extractants used to extract soluble heavy metals from soils of an ordinary chernozem type in agrochemical procedures using ultrasonic treatment were classified in accordance with the element nature [ru

  4. 9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.

    Science.gov (United States)

    2010-01-01

    ... samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic... for diagnostic testing. (b) The authorized laboratory must identify each egg as to the breeding flock...

  5. Soil an-d nutrient loss following site preparation burning

    Science.gov (United States)

    E.A. Carter; J.P. Field; K.W. Farrish

    2000-01-01

    Sediment loss and nutrient cpncentrations in runoff were evaluated to determine the effects of site preparation burning on a recently harvested loblolly pine (Pinur taeda L.) site in east Texas. Sediment and nutrient losses prior to treatment were approximately the same from control plots and pretreatment burn plots. Nutrient analysis of runoff samples indicated that...

  6. Analytical sample preparation strategies for the determination of antimalarial drugs in human whole blood, plasma and urine

    DEFF Research Database (Denmark)

    Casas, Monica Escolà; Hansen, Martin; Krogh, Kristine A

    2014-01-01

    the available sample preparation strategies combined with liquid chromatographic (LC) analysis to determine antimalarials in whole blood, plasma and urine published over the last decade. Sample preparation can be done by protein precipitation, solid-phase extraction, liquid-liquid extraction or dilution. After...

  7. New sample preparation method based on task-specific ionic liquids for extraction and determination of copper in urine and wastewater.

    Science.gov (United States)

    Trtić-Petrović, Tatjana; Dimitrijević, Aleksandra; Zdolšek, Nikola; Đorđević, Jelena; Tot, Aleksandar; Vraneš, Milan; Gadžurić, Slobodan

    2018-01-01

    In this study, four hydrophilic ionic liquids (ILs) containing 1-alkyl-3-methylimidazolim cation and either salicylate or chloride anions were synthetized and studied as new task-specific ionic liquids (TSILs) suitable for aqueous biphasic system (ABS) formation and selective one-step extraction of copper(II). TSILs are designed so that the anion is responsible for forming the complex with metal(II) and preventing hydrolysis of metal cations at very strong alkaline pH, whereas the cation is responsible for selective extraction of metal(II)-salicylate complexes. It was found that 1-butyl-3-methylimidazolium salicylate could be used for selective extraction of Cu(II) in the presence of Zn(II), Cd(II), and Pb(II) at very alkaline solution without metal hydroxide formation. It was assumed that formation of metal(II)-salicylate complexes prevents the hydrolysis of the metal ions in alkaline solutions. The determined stability constants for Cu(II)-salicylate complexes, where salicylate was derived from different ionic liquids, indicated that there was no significant influence of the cation of the ionic liquid on the stability of the complexes. The ABS based on 1-butyl-3-methylimidazolium salicylate has been applied as the sample preparation step prior to voltammetric determination of Cu(II). The effect of volume of aqueous sample and IL and extraction time were investigated and optimum extraction conditions were determined. The obtained detection limits were 8 ng dm -3 . The optimized method was applied for the determination of Cu(II) in tap water, wastewater, and urine. The study indicated that application of the ABS based on 1-butyl-3-methylimidazolium salicylate ionic liquid could be successfully applied as the sample preparation method for the determination of Cu(II) from various environmental samples. Graphical abstract Aqueous biphasic system based on task-specific ionic liquid as a sample pretreatment for selective determination of Cu(II) in biological and

  8. A Simple and Reproducible Method to Prepare Membrane Samples from Freshly Isolated Rat Brain Microvessels.

    Science.gov (United States)

    Brzica, Hrvoje; Abdullahi, Wazir; Reilly, Bianca G; Ronaldson, Patrick T

    2018-05-07

    The blood-brain barrier (BBB) is a dynamic barrier tissue that responds to various pathophysiological and pharmacological stimuli. Such changes resulting from these stimuli can greatly modulate drug delivery to the brain and, by extension, cause considerable challenges in the treatment of central nervous system (CNS) diseases. Many BBB changes that affect pharmacotherapy, involve proteins that are localized and expressed at the level of endothelial cells. Indeed, such knowledge on BBB physiology in health and disease has sparked considerable interest in the study of these membrane proteins. From a basic science research standpoint, this implies a requirement for a simple but robust and reproducible method for isolation of microvessels from brain tissue harvested from experimental animals. In order to prepare membrane samples from freshly isolated microvessels, it is essential that sample preparations be enriched in endothelial cells but limited in the presence of other cell types of the neurovascular unit (i.e., astrocytes, microglia, neurons, pericytes). An added benefit is the ability to prepare samples from individual animals in order to capture the true variability of protein expression in an experimental population. In this manuscript, details regarding a method that is utilized for isolation of rat brain microvessels and preparation of membrane samples are provided. Microvessel enrichment, from samples derived, is achieved by using four centrifugation steps where dextran is included in the sample buffer. This protocol can easily be adapted by other laboratories for their own specific applications. Samples generated from this protocol have been shown to yield robust experimental data from protein analysis experiments that can greatly aid the understanding of BBB responses to physiological, pathophysiological, and pharmacological stimuli.

  9. Improvement of a sample preparation method assisted by sodium deoxycholate for mass-spectrometry-based shotgun membrane proteomics.

    Science.gov (United States)

    Lin, Yong; Lin, Haiyan; Liu, Zhonghua; Wang, Kunbo; Yan, Yujun

    2014-11-01

    In current shotgun-proteomics-based biological discovery, the identification of membrane proteins is a challenge. This is especially true for integral membrane proteins due to their highly hydrophobic nature and low abundance. Thus, much effort has been directed at sample preparation strategies such as use of detergents, chaotropes, and organic solvents. We previously described a sample preparation method for shotgun membrane proteomics, the sodium deoxycholate assisted method, which cleverly circumvents many of the challenges associated with traditional sample preparation methods. However, the method is associated with significant sample loss due to the slightly weaker extraction/solubilization ability of sodium deoxycholate when it is used at relatively low concentrations such as 1%. Hence, we present an enhanced sodium deoxycholate sample preparation strategy that first uses a high concentration of sodium deoxycholate (5%) to lyse membranes and extract/solubilize hydrophobic membrane proteins, and then dilutes the detergent to 1% for a more efficient digestion. We then applied the improved method to shotgun analysis of proteins from rat liver membrane enriched fraction. Compared with other representative sample preparation strategies including our previous sodium deoxycholate assisted method, the enhanced sodium deoxycholate method exhibited superior sensitivity, coverage, and reliability for the identification of membrane proteins particularly those with high hydrophobicity and/or multiple transmembrane domains. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. M3FT-17OR0301070211 - Preparation of Hot Isostatically Pressed AgZ Waste Form Samples

    Energy Technology Data Exchange (ETDEWEB)

    Jubin, Robert Thomas [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bruffey, Stephanie H. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jordan, Jacob A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-10-01

    The production of radioactive iodine-bearing waste forms that exhibit long-term stability and are suitable for permanent geologic disposal has been the subject of substantial research interest. One potential method of iodine waste form production is hot isostatic pressing (HIP). Recent studies at Oak Ridge National Laboratory (ORNL) have investigated the conversion of iodine-loaded silver mordenite (I-AgZ) directly to a waste form by HIP. ORNL has performed HIP with a variety of sample compositions and pressing conditions. The base mineral has varied among AgZ (in pure and engineered forms), silver-exchanged faujasite, and silverexchanged zeolite A. Two iodine loading methods, occlusion and chemisorption, have been explored. Additionally, the effects of variations in temperature and pressure of the process have been examined, with temperature ranges of 525°C–1,100°C and pressure ranges of 100–300 MPa. All of these samples remain available to collaborators upon request. The sample preparation detailed in this document is an extension of that work. In addition to previously prepared samples, this report documents the preparation of additional samples to support stability testing. These samples include chemisorbed I-AgZ and pure AgI. Following sample preparation, each sample was processed by HIP by American Isostatic Presses Inc. and returned to ORNL for storage. ORNL will store the samples until they are requested by collaborators for durability testing. The sample set reported here will support waste form durability testing across the national laboratories and will provide insight into the effects of varied iodine content on iodine retention by the produced waste form and on potential improvements in waste form durability provided by the zeolite matrix.

  11. Collection and preparation of marine samples for radionuclide analysis

    International Nuclear Information System (INIS)

    Holm, E.

    1997-01-01

    The ultimate goal of research in radioecology is to be able to predict the pathways of radioactive material in the environment and hence estimate possible doses to the population in various regions. Knowledge of levels of contamination are necessary to maintain control of operations of nuclear facilities. Correct methods of sample collection, handling and preparation are among the most important parts for a correct assessment. On basis of the final results of radionuclide concentrations, scientific, medical and political decisions are taken. (author)

  12. Preparing Monodisperse Macromolecular Samples for Successful Biological Small-Angle X-ray and Neutron Scattering Experiments

    Science.gov (United States)

    Jeffries, Cy M.; Graewert, Melissa A.; Blanchet, Clément E.; Langley, David B.; Whitten, Andrew E.; Svergun, Dmitri I

    2017-01-01

    Small-angle X-ray and neutron scattering (SAXS and SANS) are techniques used to extract structural parameters and determine the overall structures and shapes of biological macromolecules, complexes and assemblies in solution. The scattering intensities measured from a sample contain contributions from all atoms within the illuminated sample volume including the solvent and buffer components as well as the macromolecules of interest. In order to obtain structural information, it is essential to prepare an exactly matched solvent blank so that background scattering contributions can be accurately subtracted from the sample scattering to obtain the net scattering from the macromolecules in the sample. In addition, sample heterogeneity caused by contaminants, aggregates, mismatched solvents, radiation damage or other factors can severely influence and complicate data analysis so it is essential that the samples are pure and monodisperse for the duration of the experiment. This Protocol outlines the basic physics of SAXS and SANS and reveals how the underlying conceptual principles of the techniques ultimately ‘translate’ into practical laboratory guidance for the production of samples of sufficiently high quality for scattering experiments. The procedure describes how to prepare and characterize protein and nucleic acid samples for both SAXS and SANS using gel electrophoresis, size exclusion chromatography and light scattering. Also included are procedures specific to X-rays (in-line size exclusion chromatography SAXS) and neutrons, specifically preparing samples for contrast matching/variation experiments and deuterium labeling of proteins. PMID:27711050

  13. Sulfonate-terminated carbosilane dendron-coated nanotubes: a greener point of view in protein sample preparation.

    Science.gov (United States)

    González-García, Estefanía; Gutiérrez Ulloa, Carlos E; de la Mata, Francisco Javier; Marina, María Luisa; García, María Concepción

    2017-09-01

    Reduction or removal of solvents and reagents in protein sample preparation is a requirement. Dendrimers can strongly interact with proteins and have great potential as a greener alternative to conventional methods used in protein sample preparation. This work proposes the use of single-walled carbon nanotubes (SWCNTs) functionalized with carbosilane dendrons with sulfonate groups for protein sample preparation and shows the successful application of the proposed methodology to extract proteins from a complex matrix. SEM images of nanotubes and mixtures of nanotubes and proteins were taken. Moreover, intrinsic fluorescence intensity of proteins was monitored to observe the most significant interactions at increasing dendron generations under neutral and basic pHs. Different conditions for the disruption of interactions between proteins and nanotubes after protein extraction and different concentrations of the disrupting reagent and the nanotube were also tried. Compatibility of extraction and disrupting conditions with the enzymatic digestion of proteins for obtaining bioactive peptides was also studied. Finally, sulfonate-terminated carbosilane dendron-coated SWCNTs enabled the extraction of proteins from a complex sample without using non-environmentally friendly solvents that were required so far. Graphical Abstract Green protein extraction from a complex sample employing carbosilane dendron coated nanotubes.

  14. Preparation Of Deposited Sediment Sample By Casting Method For Environmental Study

    International Nuclear Information System (INIS)

    Hutabarat, Tommy; Ristin PI, Evarista

    2000-01-01

    The preparation of deposited sediment sample by c asting m ethod for environmental study has been carried out. This method comprises separation of size fraction and casting process. The deposited sediment samples were wet sieved to separate the size fraction of >500 mum, (250-500) mum, (125-250) mum and (63-125) mum and settling procedures were followed for the separation of (40-63) mum, (20-40) mum, (10-20) mum and o C, ashed at 450 o C, respectively. In the casting process of sample, it was used polyester rapid cure resin and methyl ethyl ketone peroxide (MEKP) hardener. The moulded sediment sample was poured onto caster, allow for 60 hours long. The aim of this method is to get the casted sample which can be used effectively, efficiently and to be avoided from contamination of each other samples. Before casting, samples were grinded up to be fine. The result shows that casting product is ready to be used for natural radionuclide analysis

  15. Ferromagnetic particles as a rapid and robust sample preparation for the absolute quantification of seven eicosanoids in human plasma by UHPLC-MS/MS.

    Science.gov (United States)

    Suhr, Anna Catharina; Bruegel, Mathias; Maier, Barbara; Holdt, Lesca Miriam; Kleinhempel, Alisa; Teupser, Daniel; Grimm, Stefanie H; Vogeser, Michael

    2016-06-01

    We used ferromagnetic particles as a novel technique to deproteinize plasma samples prior to quantitative UHPLC-MS/MS analysis of seven eicosanoids [thromboxane B2 (TXB2), prostaglandin E2 (PGE2), PGD2, 5-hydroxyeicosatetraenoic acid (5-HETE), 11-HETE, 12-HETE, arachidonic acid (AA)]. A combination of ferromagnetic particle enhanced deproteination and subsequent on-line solid phase extraction (on-line SPE) realized quick and convenient semi-automated sample preparation-in contrast to widely used manual SPE techniques which are rather laborious and therefore impede the investigation of AA metabolism in larger patient cohorts. Method evaluation was performed according to a protocol based on the EMA guideline for bioanalytical method validation, modified for endogenous compounds. Calibrators were prepared in ethanol. The calibration curves were found to be linear in a range of 0.1-80ngmL(-1) (TXB2, PGE2, PGD2), 0.05-40ngmL(-1) (5-HETE, 11-HETE), 0.5-400ngmL(-1) (12-HETE) and 25-9800ngmL(-1) (AA). Regarding all analytes and all quality controls, the resulting precision data (inter-assay 2.6 %-15.5 %; intra-assay 2.5 %-15.1 %, expressed as variation coefficient) as well as the accuracy results (inter-assay 93.3 %-125 %; intra-assay 91.7 %-114 %) were adequate. Further experiments addressing matrix effect, recovery and robustness, yielded also very satisfying results. As a proof of principle, the newly developed LC-MS/MS assay was employed to determine the capacity of AA metabolite release after whole blood stimulation in healthy blood donors. For this purpose, whole blood specimens of 5 healthy blood donors were analyzed at baseline and after a lipopolysaccharide (LPS) induced blood cell activation. In several baseline samples some eicosanoids levels were below the Lower Limit of Quantification. However, in the stimulated samples all chosen eicosanoids (except PGD2) could be quantified. These results, in context with those obtained in validation, demonstrate the

  16. XRF analysis of mineralised samples

    International Nuclear Information System (INIS)

    Ahmedali, T.

    2002-01-01

    Full text: Software now supplied by instrument manufacturers has made it practical and convenient for users to analyse unusual samples routinely. Semiquantitative scanning software can be used for rapid preliminary screening of elements ranging from Carbon to Uranium, prior to assigning mineralised samples to an appropriate quantitative analysis routine. The general quality and precision of analytical results obtained from modern XRF spectrometers can be significantly enhanced by several means: a. Modifications in preliminary sample preparation can result in less contamination from crushing and grinding equipment. Optimised techniques of actual sample preparation can significantly increase precision of results. b. Employment of automatic data recording balances and the use of catch weights during sample preparation reduces technician time as well as weighing errors. * c. Consistency of results can be improved significantly by the use of appropriate stable drift monitors with a statistically significant content of the analyte d. A judicious selection of kV/mA combinations, analysing crystals, primary beam filters, collimators, peak positions, accurate background correction and peak overlap corrections, followed by the use of appropriate matrix correction procedures. e. Preventative maintenance procedures for XRF spectrometers and ancillary equipment, which can also contribute significantly to reducing instrument down times, are described. Examples of various facets of sample processing routines are given from the XRF spectrometer component of a multi-instrument analytical university facility, which provides XRF data to 17 Canadian universities. Copyright (2002) Australian X-ray Analytical Association Inc

  17. Challenges of biological sample preparation for SIMS imaging of elements and molecules at subcellular resolution

    International Nuclear Information System (INIS)

    Chandra, Subhash

    2008-01-01

    Secondary ion mass spectrometry (SIMS) based imaging techniques capable of subcellular resolution characterization of elements and molecules are becoming valuable tools in many areas of biology and medicine. Due to high vacuum requirements of SIMS, the live cells cannot be analyzed directly in the instrument. The sample preparation, therefore, plays a critical role in preserving the native chemical composition for SIMS analysis. This work focuses on the evaluation of frozen-hydrated and frozen freeze-dried sample preparations for SIMS studies of cultured cells with a CAMECA IMS-3f dynamic SIMS ion microscope instrument capable of producing SIMS images with a spatial resolution of 500 nm. The sandwich freeze-fracture method was used for fracturing the cells. The complimentary fracture planes in the plasma membrane were characterized by field-emission secondary electron microscopy (FESEM) in the frozen-hydrated state. The cells fractured at the dorsal surface were used for SIMS analysis. The frozen-hydrated SIMS analysis of individual cells under dynamic primary ion beam (O 2 + ) revealed local secondary ion signal enhancements correlated with the water image signals of 19 (H 3 O) + . A preferential removal of water from the frozen cell matrix in the Z-axis was also observed. These complications render the frozen-hydrated sample type less desirable for subcellular dynamic SIMS studies. The freeze-drying of frozen-hydrated cells, either inside the instrument or externally in a freeze-drier, allowed SIMS imaging of subcellular chemical composition. Morphological evaluations of fractured freeze-dried cells with SEM and confocal laser scanning microscopy (CLSM) revealed well-preserved mitochondria, Golgi apparatus, and stress fibers. SIMS analysis of fractured freeze-dried cells revealed well-preserved chemical composition of even the most highly diffusible ions like K + and Na + in physiologically relevant concentrations. The high K-low Na signature in individual cells

  18. Challenges of biological sample preparation for SIMS imaging of elements and molecules at subcellular resolution

    Science.gov (United States)

    Chandra, Subhash

    2008-12-01

    Secondary ion mass spectrometry (SIMS) based imaging techniques capable of subcellular resolution characterization of elements and molecules are becoming valuable tools in many areas of biology and medicine. Due to high vacuum requirements of SIMS, the live cells cannot be analyzed directly in the instrument. The sample preparation, therefore, plays a critical role in preserving the native chemical composition for SIMS analysis. This work focuses on the evaluation of frozen-hydrated and frozen freeze-dried sample preparations for SIMS studies of cultured cells with a CAMECA IMS-3f dynamic SIMS ion microscope instrument capable of producing SIMS images with a spatial resolution of 500 nm. The sandwich freeze-fracture method was used for fracturing the cells. The complimentary fracture planes in the plasma membrane were characterized by field-emission secondary electron microscopy (FESEM) in the frozen-hydrated state. The cells fractured at the dorsal surface were used for SIMS analysis. The frozen-hydrated SIMS analysis of individual cells under dynamic primary ion beam (O 2+) revealed local secondary ion signal enhancements correlated with the water image signals of 19(H 3O) +. A preferential removal of water from the frozen cell matrix in the Z-axis was also observed. These complications render the frozen-hydrated sample type less desirable for subcellular dynamic SIMS studies. The freeze-drying of frozen-hydrated cells, either inside the instrument or externally in a freeze-drier, allowed SIMS imaging of subcellular chemical composition. Morphological evaluations of fractured freeze-dried cells with SEM and confocal laser scanning microscopy (CLSM) revealed well-preserved mitochondria, Golgi apparatus, and stress fibers. SIMS analysis of fractured freeze-dried cells revealed well-preserved chemical composition of even the most highly diffusible ions like K + and Na + in physiologically relevant concentrations. The high K-low Na signature in individual cells

  19. 14C sample preparation for AMS microdosing studies at Lund University using online combustion and septa-sealed vials

    Science.gov (United States)

    Sydoff, Marie; Stenström, Kristina

    2010-04-01

    The Department of Physics at Lund University is participating in a European Union project called EUMAPP (European Union Microdose AMS Partnership Programme), in which sample preparation and accelerator mass spectrometry (AMS) measurements of biological samples from microdosing studies have been made. This paper describes a simplified method of converting biological samples to solid graphite for 14C analysis with AMS. The method is based on online combustion of the samples, and reduction of CO 2 in septa-sealed vials. The septa-sealed vials and disposable materials are used to eliminate sample cross-contamination. Measurements of ANU and Ox I standards show deviations of 2% and 3%, respectively, relative to reference values. This level of accuracy is sufficient for biological samples from microdosing studies. Since the method has very few handling steps from sample to graphite, the risk of failure during the sample preparation process is minimized, making the method easy to use in routine preparation of samples.

  20. 14C sample preparation for AMS microdosing studies at Lund University using online combustion and septa-sealed vials

    International Nuclear Information System (INIS)

    Sydoff, Marie; Stenstroem, Kristina

    2010-01-01

    The Department of Physics at Lund University is participating in a European Union project called EUMAPP (European Union Microdose AMS Partnership Programme), in which sample preparation and accelerator mass spectrometry (AMS) measurements of biological samples from microdosing studies have been made. This paper describes a simplified method of converting biological samples to solid graphite for 14 C analysis with AMS. The method is based on online combustion of the samples, and reduction of CO 2 in septa-sealed vials. The septa-sealed vials and disposable materials are used to eliminate sample cross-contamination. Measurements of ANU and Ox I standards show deviations of 2% and 3%, respectively, relative to reference values. This level of accuracy is sufficient for biological samples from microdosing studies. Since the method has very few handling steps from sample to graphite, the risk of failure during the sample preparation process is minimized, making the method easy to use in routine preparation of samples.

  1. Separation and enrichment of gold(III) from environmental samples prior to its flame atomic absorption spectrometric determination

    International Nuclear Information System (INIS)

    Senturk, Hasan Basri; Gundogdu, Ali; Bulut, Volkan Numan; Duran, Celal; Soylak, Mustafa; Elci, Latif; Tufekci, Mehmet

    2007-01-01

    A simple and accurate method was developed for separation and enrichment of trace levels of gold in environmental samples. The method is based on the adsorption of Au(III)-diethyldithiocarbamate complex on Amberlite XAD-2000 resin prior to the analysis of gold by flame atomic absorption spectrometry after elution with 1 mol L -1 HNO 3 in acetone. Some parameters including nitric acid concentration, eluent type, matrix ions, sample volume, sample flow rate and adsorption capacity were investigated on the recovery of gold(III). The recovery values for gold(III) and detection limit of gold were greater than 95% and 16.6 μg L -1 , respectively. The preconcentration factor was 200. The relative standard deviation of the method was -1 . The validation of the presented procedure was checked by the analysis of CRM-SA-C Sandy Soil certified reference material. The presented procedure was applied to the determination of gold in some environmental samples

  2. Sample preparation method for ICP-MS measurement of 99Tc in a large amount of environmental samples

    International Nuclear Information System (INIS)

    Kondo, M.; Seki, R.

    2002-01-01

    Sample preparation for measurement of 99 Tc in a large amount of soil and water samples by ICP-MS has been developed using 95m Tc as a yield tracer. This method is based on the conventional method for a small amount of soil samples using incineration, acid digestion, extraction chromatography (TEVA resin) and ICP-MS measurement. Preliminary concentration of Tc has been introduced by co-precipitation with ferric oxide. The matrix materials in a large amount of samples were more sufficiently removed with keeping the high recovery of Tc than previous method. The recovery of Tc was 70-80% for 100 g soil samples and 60-70% for 500 g of soil and 500 L of water samples. The detection limit of this method was evaluated as 0.054 mBq/kg in 500 g soil and 0.032 μBq/L in 500 L water. The determined value of 99 Tc in the IAEA-375 (soil sample collected near the Chernobyl Nuclear Reactor) was 0.25 ± 0.02 Bq/kg. (author)

  3. A critical review of microextraction by packed sorbent as a sample preparation approach in drug bioanalysis.

    Science.gov (United States)

    Alves, Gilberto; Rodrigues, Márcio; Fortuna, Ana; Falcão, Amílcar; Queiroz, João

    2013-06-01

    Sample preparation is widely accepted as the most labor-intensive and error-prone part of the bioanalytical process. The recent advances in this field have been focused on the miniaturization and integration of sample preparation online with analytical instrumentation, in order to reduce laboratory workload and increase analytical performance. From this perspective, microextraction by packed sorbent (MEPS) has emerged in the last few years as a powerful sample preparation approach suitable to be easily automated with liquid and gas chromatographic systems applied in a variety of bioanalytical areas (pharmaceutical, clinical, toxicological, environmental and food research). This paper aims to provide an overview and a critical discussion of recent bioanalytical methods reported in literature based on MEPS, with special emphasis on those developed for the quantification of therapeutic drugs and/or metabolites in biological samples. The advantages and some limitations of MEPS, as well as its comparison with other extraction techniques, are also addressed herein.

  4. Quality Assessment of Platelet-Rich Fibrin-Like Matrix Prepared from Whole Blood Samples after Extended Storage

    Directory of Open Access Journals (Sweden)

    Hideo Kawabata

    2017-09-01

    Full Text Available The platelet-rich fibrin–like matrix (PRFM is usually prepared onsite and immediately used for regenerative therapy. Nonetheless, to meet the clinical necessity of preserving the PRFM without quality deterioration, we developed a method for preparation of PRFMs from short-term-stored whole blood (WB samples. In this study, to evaluate the practical expiration date of storage, we extended the storage time of WB samples from 2 to 7 days and assessed the quality of the resulting PRFMs. WB samples collected with acid-citrate-dextrose were stored with gentle agitation at ambient temperature. To prepare PRFMs, the stored WB samples were mixed with CaCl2 in glass tubes and centrifuged. Fibrin fiber networks, CD41 and CD62P expression, and Platelet Derived Growth Factor-BB (PDGF-BB levels were examined by scanning electron microscopy (SEM, flow cytometry, and an Enzyme-Linked ImmunoSorbent Assay (ELISA, respectively. Long-term storage had no significant effect on either blood cell counts or platelet functions tested. The resulting PRFMs were visually identical to freshly prepared ones. PDGF-BB levels did not markedly decrease in a time-dependent manner. However, fibrin fibers gradually became thinner after storage. Although the coagulation activity may diminish, we propose that PRFMs can be prepared—without evident loss of quality—from WB samples stored for up to 7 days by our previously developed method.

  5. Development of a Novel Self-Enclosed Sample Preparation Device for DNA/RNA Isolation in Space

    Science.gov (United States)

    Zhang, Ye; Mehta, Satish K.; Pensinger, Stuart J.; Pickering, Karen D.

    2011-01-01

    Modern biology techniques present potentials for a wide range of molecular, cellular, and biochemistry applications in space, including detection of infectious pathogens and environmental contaminations, monitoring of drug-resistant microbial and dangerous mutations, identification of new phenotypes of microbial and new life species. However, one of the major technological blockades in enabling these technologies in space is a lack of devices for sample preparation in the space environment. To overcome such an obstacle, we constructed a prototype of a DNA/RNA isolation device based on our novel designs documented in the NASA New Technology Reporting System (MSC-24811-1/3-1). This device is self-enclosed and pipette free, purposely designed for use in the absence of gravity. Our design can also be modified easily for preparing samples in space for other applications, such as flowcytometry, immunostaining, cell separation, sample purification and separation according to its size and charges, sample chemical labeling, and sample purification. The prototype of our DNA/RNA isolation device was tested for efficiencies of DNA and RNA isolation from various cell types for PCR analysis. The purity and integrity of purified DNA and RNA were determined as well. Results showed that our developed DNA/RNA isolation device offers similar efficiency and quality in comparison to the samples prepared using the standard protocol in the laboratory.

  6. Soil and Water – What is Detectable through Microbiological Sample Preparation Techniques

    Science.gov (United States)

    The concerns of a potential terrorist’s use of biological agents in soil and ground water are articulated by comparisons to major illnesses in this Country involving contaminated drinking water sources. Objectives are focused on the importance of sample preparation in the rapid, ...

  7. Fluoroquinolone antibiotics in environmental waters: sample preparation and determination.

    Science.gov (United States)

    Speltini, Andrea; Sturini, Michela; Maraschi, Federica; Profumo, Antonella

    2010-04-01

    The aim of this review is to provide a general overview on the analytical methods proposed in the last decade for trace fluoroquinolone (FQ) determination in environmental waters. A large number of studies have been developed on this topic in reason of the importance of their monitoring in the studies of environmental mobility and potential degradation pathways. Every step of the analysis has been carefully considered, with a particular attention to sample preparation, in relationship with the problems involved in the analysis of real matrices. The different strategies to minimise interference from organic matter and to achieve optimal sensitivity, especially important in those samples with lower FQ concentrations, were also highlighted. Results and progress in this field have been described and critically commented. Moreover, a worldwide overview on the presence of FQs in the environmental waters has been reported.

  8. Lessons Learned from Preparing OSIRIS-REx Spectral Analog Samples for Bennu

    Science.gov (United States)

    Schrader, D. L.; McCoy, T. J.; Cody, G. D.; King, A. J.; Schofield, P. F.; Russell, S. S.; Connolly, H. C., Jr.; Keller, L. P.; Donaldson Hanna, K.; Bowles, N.; hide

    2017-01-01

    NASA's OSIRIS-REx sample return mission launched on September 8th, 2016 to rendezvous with B-type asteroid (101955) Bennu in 2018. Type C and B asteroids have been linked to carbonaceous chondrites because of their similar visible - to - near infrared (VIS-NIR) spectral properties [e.g., 1,2]. The OSIRIS-REx Visible and Infrared Spectrometer (OVIRS) and the Thermal Emission Spectrometer (OTES) will make spectroscopic observations of Bennu during the encounter. Constraining the presence or absence of hydrous minerals (e.g., Ca-carbonate, phyllosilicates) and organic molecules will be key to characterizing Bennu [3] prior to sample site selection. The goal of this study was to develop a suite of analog and meteorite samples and obtain their spectral properties over the wavelength ranges of OVIRS (0.4- 4.3 micrometer) and OTES (5.0-50 micrometer). These spectral data were used to validate the mission science-data processing system. We discuss the reasoning behind the study and share lessons learned.

  9. Solvent-assisted dispersive solid-phase extraction: A sample preparation method for trace detection of diazinon in urine and environmental water samples.

    Science.gov (United States)

    Aladaghlo, Zolfaghar; Fakhari, Alireza; Behbahani, Mohammad

    2016-09-02

    In this research, a sample preparation method termed solvent-assisted dispersive solid-phase extraction (SA-DSPE) was applied. The used sample preparation method was based on the dispersion of the sorbent into the aqueous sample to maximize the interaction surface. In this approach, the dispersion of the sorbent at a very low milligram level was received by inserting a solution of the sorbent and disperser solvent into the aqueous sample. The cloudy solution created from the dispersion of the sorbent in the bulk aqueous sample. After pre-concentration of the diazinon, the cloudy solution was centrifuged and diazinon in the sediment phase dissolved in ethanol and determined by gas chromatography-flame ionization detector. Under the optimized conditions (pH of solution=7.0, Sorbent: benzophenone, 2%, Disperser solvent: ethanol, 500μL, Centrifuge: centrifuged at 4000rpm for 3min), the method detection limit for diazinon was 0.2, 0.3, 0.3 and 0.3μgL(-1) for distilled water, lake water, waste water and urine sample, respectively. Furthermore, the pre-concentration factor was 363.8, 356.1, 360.7 and 353.38 in distilled water, waste water, lake water and urine sample, respectively. SA-DSPE was successfully used for trace monitoring of diazinon in urine, lake and waste water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Sample Preparation Report of the Fourth OPCW Confidence Building Exercise on Biomedical Sample Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Udey, R. N. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Corzett, T. H. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Alcaraz, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2014-07-03

    Following the successful completion of the 3rd biomedical confidence building exercise (February 2013 – March 2013), which included the analysis of plasma and urine samples spiked at low ppb levels as part of the exercise scenario, another confidence building exercise was targeted to be conducted in 2014. In this 4th exercise, it was desired to focus specifically on the analysis of plasma samples. The scenario was designed as an investigation of an alleged use of chemical weapons where plasma samples were collected, as plasma has been reported to contain CWA adducts which remain present in the human body for several weeks (Solano et al. 2008). In the 3rd exercise most participants used the fluoride regeneration method to analyze for the presence of nerve agents in plasma samples. For the 4th biomedical exercise it was decided to evaluate the analysis of human plasma samples for the presence/absence of the VX adducts and aged adducts to blood proteins (e.g., VX-butyrylcholinesterase (BuChE) and aged BuChE adducts using a pepsin digest technique to yield nonapeptides; or equivalent). As the aging of VX-BuChE adducts is relatively slow (t1/2 = 77 hr at 37 °C [Aurbek et al. 2009]), soman (GD), which ages much more quickly (t1/2 = 9 min at 37 °C [Masson et al. 2010]), was used to simulate an aged VX sample. Additional objectives of this exercise included having laboratories assess novel OP-adducted plasma sample preparation techniques and analytical instrumentation methodologies, as well as refining/designating the reporting formats for these new techniques.

  11. Optimized pre-thinning procedures of ion-beam thinning for TEM sample preparation by magnetorheological polishing.

    Science.gov (United States)

    Luo, Hu; Yin, Shaohui; Zhang, Guanhua; Liu, Chunhui; Tang, Qingchun; Guo, Meijian

    2017-10-01

    Ion-beam-thinning is a well-established sample preparation technique for transmission electron microscopy (TEM), but tedious procedures and labor consuming pre-thinning could seriously reduce its efficiency. In this work, we present a simple pre-thinning technique by using magnetorheological (MR) polishing to replace manual lapping and dimpling, and demonstrate the successful preparation of electron-transparent single crystal silicon samples after MR polishing and single-sided ion milling. Dimples pre-thinned to less than 30 microns and with little mechanical surface damage were repeatedly produced under optimized MR polishing conditions. Samples pre-thinned by both MR polishing and traditional technique were ion-beam thinned from the rear side until perforation, and then observed by optical microscopy and TEM. The results show that the specimen pre-thinned by MR technique was free from dimpling related defects, which were still residual in sample pre-thinned by conventional technique. Nice high-resolution TEM images could be acquired after MR polishing and one side ion-thinning. MR polishing promises to be an adaptable and efficient method for pre-thinning in preparation of TEM specimens, especially for brittle ceramics. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Methods of biological fluids sample preparation - biogenic amines, methylxanthines, water-soluble vitamins.

    Science.gov (United States)

    Płonka, Joanna

    2015-01-01

    In recent years demands on the amount of information that can be obtained from the analysis of a single sample have increased. For time and economic reasons it is necessary to examine at the same time larger number of compounds, and compounds from different groups. This can best be seen in such areas as clinical analysis. In many diseases, the best results for patients are obtained when treatment fits the individual characteristics of the patient. Dosage monitoring is important at the beginning of therapy and in the full process of treatment. In the treatment of many diseases biogenic amines (dopamine, serotonin) and methylxanthines (theophylline, theobromine, caffeine) play an important role. They are used as drugs separately or in combination with others to support and strengthen the action of other drugs - for example, the combination of caffeine and paracetamol. Vitamin supplementation may be also an integral part of the treatment process. Specification of complete sample preparation parameters for extraction of the above compounds from biological matrices has been reviewed. Particular attention was given to the preparation stage and extraction methods. This review provides universal guidance on establishing a common procedures across laboratories to facilitate the preparation and analysis of all discussed compounds. Copyright © 2014 John Wiley & Sons, Ltd.

  13. Recent trends in sorption-based sample preparation and liquid chromatography techniques for food analysis.

    Science.gov (United States)

    V Soares Maciel, Edvaldo; de Toffoli, Ana Lúcia; Lanças, Fernando Mauro

    2018-04-20

    The accelerated rising of the world's population increased the consumption of food, thus demanding more rigors in the control of residue and contaminants in food-based products marketed for human consumption. In view of the complexity of most food matrices, including fruits, vegetables, different types of meat, beverages, among others, a sample preparation step is important to provide more reliable results when combined with HPLC separations. An adequate sample preparation step before the chromatographic analysis is mandatory in obtaining higher precision and accuracy in order to improve the extraction of the target analytes, one of the priorities in analytical chemistry. The recent discovery of new materials such as ionic liquids, graphene-derived materials, molecularly imprinted polymers, restricted access media, magnetic nanoparticles, and carbonaceous nanomaterials, provided high sensitivity and selectivity results in an extensive variety of applications. These materials, as well as their several possible combinations, have been demonstrated to be highly appropriate for the extraction of different analytes in complex samples such as food products. The main characteristics and application of these new materials in food analysis will be presented and discussed in this paper. Another topic discussed in this review covers the main advantages and limitations of sample preparation microtechniques, as well as their off-line and on-line combination with HPLC for food analysis. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Molecularly imprinted polymers for sample preparation and biosensing in food analysis: Progress and perspectives.

    Science.gov (United States)

    Ashley, Jon; Shahbazi, Mohammad-Ali; Kant, Krishna; Chidambara, Vinayaka Aaydha; Wolff, Anders; Bang, Dang Duong; Sun, Yi

    2017-05-15

    Molecularly imprinted polymers (MIPs) are biomimetics which can selectively bind to analytes of interest. One of the most interesting areas where MIPs have shown the biggest potential is food analysis. MIPs have found use as sorbents in sample preparation attributed to the high selectivity and high loading capacity. MIPs have been intensively employed in classical solid-phase extraction and solid-phase microextraction. More recently, MIPs have been combined with magnetic bead extraction, which greatly simplifies sample handling procedures. Studies have consistently shown that MIPs can effectively minimize complex food matrix effects, and improve recoveries and detection limits. In addition to sample preparation, MIPs have also been viewed as promising alternatives to bio-receptors due to the inherent molecular recognition abilities and the high stability in harsh chemical and physical conditions. MIPs have been utilized as receptors in biosensing platforms such as electrochemical, optical and mass biosensors to detect various analytes in food. In this review, we will discuss the current state-of-the-art of MIP synthesis and applications in the context of food analysis. We will highlight the imprinting methods which are applicable for imprinting food templates, summarize the recent progress in using MIPs for preparing and analysing food samples, and discuss the current limitations in the commercialisation of MIPs technology. Finally, future perspectives will be given. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Diagnostic PCR: validation and sample preparation are two sides of the same coin

    DEFF Research Database (Denmark)

    Hoorfar, Jeffrey; Wolffs, Petra; Radstrøm, Peter

    2004-01-01

    Increased use of powerful PCR technology for the routine detection of pathogens has focused attention on the need for international validation and preparation of official non-commercial guidelines. Bacteria of epidemiological importance should be the prime focus, although a "validation...... of quantitative reference DNA material and reagents, production of stringent protocols and tools for thermal cycler performance testing, uncomplicated sample preparation techniques, and extensive ring trials for assessment of the efficacy of selected matrix/pathogen detection protocols....

  16. The Proteome of Ulcerative Colitis in Colon Biopsies from Adults - Optimized Sample Preparation and Comparison with Healthy Controls.

    Science.gov (United States)

    Schniers, Armin; Anderssen, Endre; Fenton, Christopher Graham; Goll, Rasmus; Pasing, Yvonne; Paulssen, Ruth Hracky; Florholmen, Jon; Hansen, Terkel

    2017-12-01

    The purpose of the study was to optimize the sample preparation and to further use an improved sample preparation to identify proteome differences between inflamed ulcerative colitis tissue from untreated adults and healthy controls. To optimize the sample preparation, we studied the effect of adding different detergents to a urea containing lysis buffer for a Lys-C/trypsin tandem digestion. With the optimized method, we prepared clinical samples from six ulcerative colitis patients and six healthy controls and analysed them by LC-MS/MS. We examined the acquired data to identify differences between the states. We improved the protein extraction and protein identification number by utilizing a urea and sodium deoxycholate containing buffer. Comparing ulcerative colitis and healthy tissue, we found 168 of 2366 identified proteins differently abundant. Inflammatory proteins are higher abundant in ulcerative colitis, proteins related to anion-transport and mucus production are lower abundant. A high proportion of S100 proteins is differently abundant, notably with both up-regulated and down-regulated proteins. The optimized sample preparation method will improve future proteomic studies on colon mucosa. The observed protein abundance changes and their enrichment in various groups improve our understanding of ulcerative colitis on protein level. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. An Integrated Solution-Based Rapid Sample Preparation Procedure for the Analysis of N-Glycans From Therapeutic Monoclonal Antibodies.

    Science.gov (United States)

    Aich, Udayanath; Liu, Aston; Lakbub, Jude; Mozdzanowski, Jacek; Byrne, Michael; Shah, Nilesh; Galosy, Sybille; Patel, Pramthesh; Bam, Narendra

    2016-03-01

    Consistent glycosylation in therapeutic monoclonal antibodies is a major concern in the biopharmaceutical industry as it impacts the drug's safety and efficacy and manufacturing processes. Large numbers of samples are created for the analysis of glycans during various stages of recombinant proteins drug development. Profiling and quantifying protein N-glycosylation is important but extremely challenging due to its microheterogeneity and more importantly the limitations of existing time-consuming sample preparation methods. Thus, a quantitative method with fast sample preparation is crucial for understanding, controlling, and modifying the glycoform variance in therapeutic monoclonal antibody development. Presented here is a rapid and highly quantitative method for the analysis of N-glycans from monoclonal antibodies. The method comprises a simple and fast solution-based sample preparation method that uses nontoxic reducing reagents for direct labeling of N-glycans. The complete work flow for the preparation of fluorescently labeled N-glycans takes a total of 3 h with less than 30 min needed for the release of N-glycans from monoclonal antibody samples. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  18. Cost-constrained optimal sampling for system identification in pharmacokinetics applications with population priors and nuisance parameters.

    Science.gov (United States)

    Sorzano, Carlos Oscars S; Pérez-De-La-Cruz Moreno, Maria Angeles; Burguet-Castell, Jordi; Montejo, Consuelo; Ros, Antonio Aguilar

    2015-06-01

    Pharmacokinetics (PK) applications can be seen as a special case of nonlinear, causal systems with memory. There are cases in which prior knowledge exists about the distribution of the system parameters in a population. However, for a specific patient in a clinical setting, we need to determine her system parameters so that the therapy can be personalized. This system identification is performed many times by measuring drug concentrations in plasma. The objective of this work is to provide an irregular sampling strategy that minimizes the uncertainty about the system parameters with a fixed amount of samples (cost constrained). We use Monte Carlo simulations to estimate the average Fisher's information matrix associated to the PK problem, and then estimate the sampling points that minimize the maximum uncertainty associated to system parameters (a minimax criterion). The minimization is performed employing a genetic algorithm. We show that such a sampling scheme can be designed in a way that is adapted to a particular patient and that it can accommodate any dosing regimen as well as it allows flexible therapeutic strategies. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.

  19. Speciation of Tl(III and Tl(I in hair samples by dispersive liquid–liquid microextraction based on solidification of floating organic droplet prior to flame atomic absorption spectrometry determination

    Directory of Open Access Journals (Sweden)

    S.Z. Mohammadi

    2016-11-01

    Full Text Available Dispersive liquid–liquid microextraction based on solidification of floating organic droplet was successfully used as a sample preparation method prior to flame atomic absorption determination of trace amounts of Tl(III and Tl(I in hair samples. In the proposed method, 1-(2-pyridylazo-2-naphthol, 1-dodecanol and ethanol were used as chelating agent, extraction and dispersive solvent, respectively. Several factors that may be affected in the extraction process, such as type and volume of extraction and disperser solvents, pH, salting out effect, ionic strength and extraction time were studied. Under the optimal conditions, linearity was maintained between 6.0 and 900.0 ng mL−1 for Tl(III. The relative standard deviation for seven replicate determinations of 0.2 μg mL−1 Tl(III was 2.5%. The detection limit based on 3Sb for Tl(III in the original solution was 2.1 ng mL−1. The proposed method has been applied for the determination of trace amounts of thallium in hair samples and satisfactory results were obtained.

  20. Universal nucleic acids sample preparation method for cells, spores and their mixture

    Science.gov (United States)

    Bavykin, Sergei [Darien, IL

    2011-01-18

    The present invention relates to a method for extracting nucleic acids from biological samples. More specifically the invention relates to a universal method for extracting nucleic acids from unidentified biological samples. An advantage of the presently invented method is its ability to effectively and efficiently extract nucleic acids from a variety of different cell types including but not limited to prokaryotic or eukaryotic cells and/or recalcitrant organisms (i.e. spores). Unlike prior art methods which are focused on extracting nucleic acids from vegetative cell or spores, the present invention effectively extracts nucleic acids from spores, multiple cell types or mixtures thereof using a single method. Important that the invented method has demonstrated an ability to extract nucleic acids from spores and vegetative bacterial cells with similar levels effectiveness. The invented method employs a multi-step protocol which erodes the cell structure of the biological sample, isolates, labels, fragments nucleic acids and purifies labeled samples from the excess of dye.

  1. Sample Preparation for Determination of Biological Thiols by Liquid Chromatography and Electromigration Techniques

    OpenAIRE

    Bald, Edward

    2004-01-01

    Wydrukowano z dostarczonych Wydawnictwu UŁ gotowych materiałów Majority of the bioanalytical or environmental methods do not use just one chromatografie or electrophoretic step, but rather involve several sample pretreatment steps which simplfy the matrix, and often preconcentrate and chemically modify the analytes. This work surveys typical procedures for sample preparation for most commonly analyzed biofluids with particular emphasis placed on chemical derivatization of su...

  2. A METHOD FOR PREPARING A SUBSTRATE BY APPLYING A SAMPLE TO BE ANALYSED

    DEFF Research Database (Denmark)

    2017-01-01

    The invention relates to a method for preparing a substrate (105a) comprising a sample reception area (110) and a sensing area (111). The method comprises the steps of: 1) applying a sample on the sample reception area; 2) rotating the substrate around a predetermined axis; 3) during rotation......, at least part of the liquid travels from the sample reception area to the sensing area due to capillary forces acting between the liquid and the substrate; and 4) removing the wave of particles and liquid formed at one end of the substrate. The sensing area is closer to the predetermined axis than...... the sample reception area. The sample comprises a liquid part and particles suspended therein....

  3. Importance of Sample Preparation for Molecular Diagnosis of Lyme Borreliosis from Urine

    OpenAIRE

    Bergmann, A. R.; Schmidt, B. L.; Derler, A.-M.; Aberer, E.

    2002-01-01

    Urine PCR has been used for the diagnosis of Borrelia burgdorferi infection in recent years but has been abandoned because of its low sensitivity and the irreproducibility of the results. Our study aimed to analyze technical details related to sample preparation and detection methods. Crucial for a successful urine PCR were (i) avoidance of the first morning urine sample; (ii) centrifugation at 36,000 × g; and (iii) the extraction method, with only DNAzol of the seven different extraction met...

  4. Recent advances in metal-organic frameworks and covalent organic frameworks for sample preparation and chromatographic analysis.

    Science.gov (United States)

    Wang, Xuan; Ye, Nengsheng

    2017-12-01

    In the field of analytical chemistry, sample preparation and chromatographic separation are two core procedures. The means by which to improve the sensitivity, selectivity and detection limit of a method have become a topic of great interest. Recently, porous organic frameworks, such as metal-organic frameworks (MOFs) and covalent organic frameworks (COFs), have been widely used in this research area because of their special features, and different methods have been developed. This review summarizes the applications of MOFs and COFs in sample preparation and chromatographic stationary phases. The MOF- or COF-based solid-phase extraction (SPE), solid-phase microextraction (SPME), gas chromatography (GC), high-performance liquid chromatography (HPLC) and capillary electrochromatography (CEC) methods are described. The excellent properties of MOFs and COFs have resulted in intense interest in exploring their performance and mechanisms for sample preparation and chromatographic separation. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. The minimum information required for a glycomics experiment (MIRAGE) project: sample preparation guidelines for reliable reporting of glycomics datasets.

    Science.gov (United States)

    Struwe, Weston B; Agravat, Sanjay; Aoki-Kinoshita, Kiyoko F; Campbell, Matthew P; Costello, Catherine E; Dell, Anne; Ten Feizi; Haslam, Stuart M; Karlsson, Niclas G; Khoo, Kay-Hooi; Kolarich, Daniel; Liu, Yan; McBride, Ryan; Novotny, Milos V; Packer, Nicolle H; Paulson, James C; Rapp, Erdmann; Ranzinger, Rene; Rudd, Pauline M; Smith, David F; Tiemeyer, Michael; Wells, Lance; York, William S; Zaia, Joseph; Kettner, Carsten

    2016-09-01

    The minimum information required for a glycomics experiment (MIRAGE) project was established in 2011 to provide guidelines to aid in data reporting from all types of experiments in glycomics research including mass spectrometry (MS), liquid chromatography, glycan arrays, data handling and sample preparation. MIRAGE is a concerted effort of the wider glycomics community that considers the adaptation of reporting guidelines as an important step towards critical evaluation and dissemination of datasets as well as broadening of experimental techniques worldwide. The MIRAGE Commission published reporting guidelines for MS data and here we outline guidelines for sample preparation. The sample preparation guidelines include all aspects of sample generation, purification and modification from biological and/or synthetic carbohydrate material. The application of MIRAGE sample preparation guidelines will lead to improved recording of experimental protocols and reporting of understandable and reproducible glycomics datasets. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. GeLC-MS: A Sample Preparation Method for Proteomics Analysis of Minimal Amount of Tissue.

    Science.gov (United States)

    Makridakis, Manousos; Vlahou, Antonia

    2017-10-10

    Application of various proteomics methodologies have been implemented for the global and targeted proteome analysis of many different types of biological samples such as tissue, urine, plasma, serum, blood, and cell lines. Among the aforementioned biological samples, tissue has an exceptional role into clinical research and practice. Disease initiation and progression is usually located at the tissue level of different organs, making the analysis of this material very important for the understanding of the disease pathophysiology. Despite the significant advances in the mass spectrometry instrumentation, tissue proteomics still faces several challenges mainly due to increased sample complexity and heterogeneity. However, the most prominent challenge is attributed to the invasive procedure of tissue sampling which restricts the availability of fresh frozen tissue to minimal amounts and limited number of samples. Application of GeLC-MS sample preparation protocol for tissue proteomics analysis can greatly facilitate making up for these difficulties. In this chapter, a step by step guide for the proteomics analysis of minute amounts of tissue samples using the GeLC-MS sample preparation protocol, as applied by our group in the analysis of multiple different types of tissues (vessels, kidney, bladder, prostate, heart) is provided.

  7. Preparation of in-house calibration source for the use in radioactivity analysis of the environmental samples. Consideration of homogeneity

    International Nuclear Information System (INIS)

    Aba, A.; Ismaeel, A.

    2013-01-01

    An in-house reference material has been prepared in Kuwait Institute for Scientific Research radioecology laboratory, for quality control purposes of gamma spectrometer systems. The material contains a known amount of uranium ore reference material (prepared by the International Atomic Energy Agency and coded as IAEA-RGU-1) which is mixed with marine sediment collected from Kuwait bay. The IAEA-RGU-1 has been certified that it is in equilibrium state with the decay daughters, and stable to be used for quality control purposes. Nevertheless, the homogeneous distribution of the doped material with the prepared source should be verified. This has been examined using gamma spectrometry measurements in conjunction with analysis of variance statistical tools, Dixon, box plots and Grubbs tests. The calculated total uncertainty has been utilized to establish the recommended specific activity ranges of 226 Ra, 224 Th, 214 Pb, 214 Bi and 210 Pb radioisotopes in the prepared source. The obtained results showed that the estimated uncertainty arising from the sample inhomogeneity has a significant contribution in the total uncertainty. The stability control charts of the ultra-low background gamma spectrometry system demonstrated the suitability of the prepared material for the purpose of quality control. However, the emitted gamma-rays from the prepared source covers the required energy range for determination of natural and artificial radionuclides in different species of environmental samples such as marine sediment, soil samples, and samples contaminated by naturally occurring radioactive material produced by oil industry. In addition, the material might be used for system calibration in case its traceability is proven. The experimental data revealed the significance of the homogeneity in preparing environmental samples for radioactivity measurements; in particular when small sample quantities of environmental samples are required to be analyzed. (author)

  8. Inverse supercritical fluid extraction as a sample preparation method for the analysis of the nanoparticle content in sunscreen agents.

    Science.gov (United States)

    Müller, David; Cattaneo, Stefano; Meier, Florian; Welz, Roland; de Vries, Tjerk; Portugal-Cohen, Meital; Antonio, Diana C; Cascio, Claudia; Calzolai, Luigi; Gilliland, Douglas; de Mello, Andrew

    2016-04-01

    We demonstrate the use of inverse supercritical carbon dioxide (scCO2) extraction as a novel method of sample preparation for the analysis of complex nanoparticle-containing samples, in our case a model sunscreen agent with titanium dioxide nanoparticles. The sample was prepared for analysis in a simplified process using a lab scale supercritical fluid extraction system. The residual material was easily dispersed in an aqueous solution and analyzed by Asymmetrical Flow Field-Flow Fractionation (AF4) hyphenated with UV- and Multi-Angle Light Scattering detection. The obtained results allowed an unambiguous determination of the presence of nanoparticles within the sample, with almost no background from the matrix itself, and showed that the size distribution of the nanoparticles is essentially maintained. These results are especially relevant in view of recently introduced regulatory requirements concerning the labeling of nanoparticle-containing products. The novel sample preparation method is potentially applicable to commercial sunscreens or other emulsion-based cosmetic products and has important ecological advantages over currently used sample preparation techniques involving organic solvents. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. {sup 14}C sample preparation for AMS microdosing studies at Lund University using online combustion and septa-sealed vials

    Energy Technology Data Exchange (ETDEWEB)

    Sydoff, Marie, E-mail: marie.sydoff@med.lu.s [Department of Clinical Sciences, Medical Radiation Physics, Malmo University Hospital, SE-205 02 Malmoe (Sweden); Lund University, Department of Physics, Division of Nuclear Physics, P.O. Box 118, SE-221 00 Lund (Sweden); Stenstroem, Kristina [Lund University, Department of Physics, Division of Nuclear Physics, P.O. Box 118, SE-221 00 Lund (Sweden)

    2010-04-15

    The Department of Physics at Lund University is participating in a European Union project called EUMAPP (European Union Microdose AMS Partnership Programme), in which sample preparation and accelerator mass spectrometry (AMS) measurements of biological samples from microdosing studies have been made. This paper describes a simplified method of converting biological samples to solid graphite for {sup 14}C analysis with AMS. The method is based on online combustion of the samples, and reduction of CO{sub 2} in septa-sealed vials. The septa-sealed vials and disposable materials are used to eliminate sample cross-contamination. Measurements of ANU and Ox I standards show deviations of 2% and 3%, respectively, relative to reference values. This level of accuracy is sufficient for biological samples from microdosing studies. Since the method has very few handling steps from sample to graphite, the risk of failure during the sample preparation process is minimized, making the method easy to use in routine preparation of samples.

  10. Electromembrane extraction as a rapid and selective miniaturized sample preparation technique for biological fluids

    DEFF Research Database (Denmark)

    Gjelstad, Astrid; Pedersen-Bjergaard, Stig; Seip, Knut Fredrik

    2015-01-01

    This special report discusses the sample preparation method electromembrane extraction, which was introduced in 2006 as a rapid and selective miniaturized extraction method. The extraction principle is based on isolation of charged analytes extracted from an aqueous sample, across a thin film....... Technical aspects of electromembrane extraction, important extraction parameters as well as a handful of examples of applications from different biological samples and bioanalytical areas are discussed in the paper....

  11. Separation and enrichment of gold(III) from environmental samples prior to its flame atomic absorption spectrometric determination

    Energy Technology Data Exchange (ETDEWEB)

    Senturk, Hasan Basri; Gundogdu, Ali [Department of Chemistry, Faculty of Arts and Sciences, Karadeniz Technical University, 61080 Trabzon (Turkey); Bulut, Volkan Numan [Department of Chemistry, Faculty of Arts and Sciences, Karadeniz Technical University, 28049 Giresun (Turkey); Duran, Celal [Department of Chemistry, Faculty of Arts and Sciences, Karadeniz Technical University, 61080 Trabzon (Turkey); Soylak, Mustafa [Department of Chemistry, Faculty of Arts and Sciences, Erciyes University, 38039 Kayseri (Turkey)], E-mail: soylak@erciyes.edu.tr; Elci, Latif [Department of Chemistry, Faculty of Arts and Sciences, Pamukkale University, 20020 Denizli (Turkey); Tufekci, Mehmet [Department of Chemistry, Faculty of Arts and Sciences, Karadeniz Technical University, 61080 Trabzon (Turkey)

    2007-10-22

    A simple and accurate method was developed for separation and enrichment of trace levels of gold in environmental samples. The method is based on the adsorption of Au(III)-diethyldithiocarbamate complex on Amberlite XAD-2000 resin prior to the analysis of gold by flame atomic absorption spectrometry after elution with 1 mol L{sup -1} HNO{sub 3} in acetone. Some parameters including nitric acid concentration, eluent type, matrix ions, sample volume, sample flow rate and adsorption capacity were investigated on the recovery of gold(III). The recovery values for gold(III) and detection limit of gold were greater than 95% and 16.6 {mu}g L{sup -1}, respectively. The preconcentration factor was 200. The relative standard deviation of the method was <6%. The adsorption capacity of the resin was 12.3 mg g{sup -1}. The validation of the presented procedure was checked by the analysis of CRM-SA-C Sandy Soil certified reference material. The presented procedure was applied to the determination of gold in some environmental samples.

  12. Review of online coupling of sample preparation techniques with liquid chromatography.

    Science.gov (United States)

    Pan, Jialiang; Zhang, Chengjiang; Zhang, Zhuomin; Li, Gongke

    2014-03-07

    Sample preparation is still considered as the bottleneck of the whole analytical procedure, and efforts has been conducted towards the automation, improvement of sensitivity and accuracy, and low comsuption of organic solvents. Development of online sample preparation techniques (SP) coupled with liquid chromatography (LC) is a promising way to achieve these goals, which has attracted great attention. This article reviews the recent advances on the online SP-LC techniques. Various online SP techniques have been described and summarized, including solid-phase-based extraction, liquid-phase-based extraction assisted with membrane, microwave assisted extraction, ultrasonic assisted extraction, accelerated solvent extraction and supercritical fluids extraction. Specially, the coupling approaches of online SP-LC systems and the corresponding interfaces have been discussed and reviewed in detail, such as online injector, autosampler combined with transport unit, desorption chamber and column switching. Typical applications of the online SP-LC techniques have been summarized. Then the problems and expected trends in this field are attempted to be discussed and proposed in order to encourage the further development of online SP-LC techniques. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Author Contribution to the Pu Handbook II: Chapter 37 LLNL Integrated Sample Preparation Glovebox (TEM) Section

    Energy Technology Data Exchange (ETDEWEB)

    Wall, Mark A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-10-25

    The development of our Integrated Actinide Sample Preparation Laboratory (IASPL) commenced in 1998 driven by the need to perform transmission electron microscopy studies on naturally aged plutonium and its alloys looking for the microstructural effects of the radiological decay process (1). Remodeling and construction of a laboratory within the Chemistry and Materials Science Directorate facilities at LLNL was required to turn a standard radiological laboratory into a Radiological Materials Area (RMA) and Radiological Buffer Area (RBA) containing type I, II and III workplaces. Two inert atmosphere dry-train glove boxes with antechambers and entry/exit fumehoods (Figure 1), having a baseline atmosphere of 1 ppm oxygen and 1 ppm water vapor, a utility fumehood and a portable, and a third double-walled enclosure have been installed and commissioned. These capabilities, along with highly trained technical staff, facilitate the safe operation of sample preparation processes and instrumentation, and sample handling while minimizing oxidation or corrosion of the plutonium. In addition, we are currently developing the capability to safely transfer small metallographically prepared samples to a mini-SEM for microstructural imaging and chemical analysis. The gloveboxes continue to be the most crucial element of the laboratory allowing nearly oxide-free sample preparation for a wide variety of LLNL-based characterization experiments, which includes transmission electron microscopy, electron energy loss spectroscopy, optical microscopy, electrical resistivity, ion implantation, X-ray diffraction and absorption, magnetometry, metrological surface measurements, high-pressure diamond anvil cell equation-of-state, phonon dispersion measurements, X-ray absorption and emission spectroscopy, and differential scanning calorimetry. The sample preparation and materials processing capabilities in the IASPL have also facilitated experimentation at world-class facilities such as the

  14. Author Contribution to the Pu Handbook II: Chapter 37 LLNL Integrated Sample Preparation Glovebox (TEM) Section

    International Nuclear Information System (INIS)

    Wall, Mark A.

    2016-01-01

    The development of our Integrated Actinide Sample Preparation Laboratory (IASPL) commenced in 1998 driven by the need to perform transmission electron microscopy studies on naturally aged plutonium and its alloys looking for the microstructural effects of the radiological decay process (1). Remodeling and construction of a laboratory within the Chemistry and Materials Science Directorate facilities at LLNL was required to turn a standard radiological laboratory into a Radiological Materials Area (RMA) and Radiological Buffer Area (RBA) containing type I, II and III workplaces. Two inert atmosphere dry-train glove boxes with antechambers and entry/exit fumehoods (Figure 1), having a baseline atmosphere of 1 ppm oxygen and 1 ppm water vapor, a utility fumehood and a portable, and a third double-walled enclosure have been installed and commissioned. These capabilities, along with highly trained technical staff, facilitate the safe operation of sample preparation processes and instrumentation, and sample handling while minimizing oxidation or corrosion of the plutonium. In addition, we are currently developing the capability to safely transfer small metallographically prepared samples to a mini-SEM for microstructural imaging and chemical analysis. The gloveboxes continue to be the most crucial element of the laboratory allowing nearly oxide-free sample preparation for a wide variety of LLNL-based characterization experiments, which includes transmission electron microscopy, electron energy loss spectroscopy, optical microscopy, electrical resistivity, ion implantation, X-ray diffraction and absorption, magnetometry, metrological surface measurements, high-pressure diamond anvil cell equation-of-state, phonon dispersion measurements, X-ray absorption and emission spectroscopy, and differential scanning calorimetry. The sample preparation and materials processing capabilities in the IASPL have also facilitated experimentation at world-class facilities such as the

  15. On the preparation of electron sensor using LiRbSO4 samples

    Science.gov (United States)

    El-Muraikhi, M.; Kassem, M. E.; Gaafar, M.; Abdel Gawad, M. M. H.; Ragab, I. M.

    2005-01-01

    The dielectric spectroscopy of metal-metal sulfate LiRbSO4 samples are described with particular emphasis on sensor performance to be used in the field of radiation. The obtained results as the effect of different electron energy beams at fixed dose, 0.5 Gy, showed abrupt change of the electrical properties (electrical conductivity, capacitance, and loss tangent). The results can be explained on the basis of radiation-induced defects followed by radiation quenching. The prepared samples can be used in the field of radiation dosimeter.

  16. Preparation of higher-actinide burnup and cross section samples

    International Nuclear Information System (INIS)

    Adair, H.L.; Kobisk, E.H.; Quinby, T.C.; Thomas, D.K.; Dailey, J.M.

    1981-01-01

    A joint research program involving the United States and the United Kingdom was instigated about four years ago for the purpose of studying burnup of higher actinides using in-core irradiation in the fast reactor at Dounreay, Scotland. Simultaneously, determination of cross sections of a wide variety of higher actinide isotopes was proposed. Coincidental neutron flux and energy spectral measurements were to be made using vanadium encapsulated dosimetry materials in the immediate region of the burnup and cross section samples. The higher actinide samples chosen for the burnup study were 241 Am and 244 Cm in the forms of Am 2 O 3 , Cm 2 O 3 , and Am 6 Cm(RE) 7 O 21 , where (RE) represents a mixture of lanthanide sesquioxides. It is the purpose of this paper to describe technology development and its application in the preparation of the fuel specimens and the cross section specimens that are being used in this cooperative program

  17. Novel sample preparation for operando TEM of catalysts.

    Science.gov (United States)

    Miller, Benjamin K; Barker, Trevor M; Crozier, Peter A

    2015-09-01

    A new TEM sample preparation method is developed to facilitate operando TEM of gas phase catalysis. A porous Pyrex-fiber pellet TEM sample was produced, allowing a comparatively large amount of catalyst to be loaded into a standard Gatan furnace-type tantalum heating holder. The increased amount of catalyst present inside the environmental TEM allows quantitative determination of the gas phase products of a catalytic reaction performed in-situ at elevated temperatures. The product gas concentration was monitored using both electron energy loss spectroscopy (EELS) and residual gas analysis (RGA). Imaging of catalyst particles dispersed over the pellet at atomic resolution is challenging, due to charging of the insulating glass fibers. To overcome this limitation, a metal grid is placed into the holder in addition to the pellet, allowing catalyst particles dispersed over the grid to be imaged, while particles in the pellet, which are assumed to experience identical conditions, contribute to the overall catalytic conversion inside the environmental TEM cell. The gas within the cell is determined to be well-mixed, making this assumption reasonable. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. New Sample Preparation Method for Quantification of Phenolic Compounds of Tea (Camellia sinensis L. Kuntze: A Polyphenol Rich Plant

    Directory of Open Access Journals (Sweden)

    P. A. Nimal Punyasiri

    2015-01-01

    Full Text Available Chemical analysis of the Sri Lankan tea (Camellia sinensis, L. germplasm would immensely contribute to the success of the tea breeding programme. However, the polyphenols, particularly catechins (flavan-3-ols, are readily prone to oxidation in the conventional method of sample preparation. Therefore, optimization of the present sample preparation methodology for the profiling of metabolites is much important. Two sample preparation methodologies were compared, fresh leaves (as in the conventional procedures and freeze-dried leaves (a new procedure, for quantification of major metabolites by employing two cultivars, one is known to be high quality black tea and the other low quality black tea. The amounts of major metabolites such as catechins, caffeine, gallic acid, and theobromine, recorded in the new sampling procedure via freeze-dried leaves, were significantly higher than those recorded in the conventional sample preparation procedure. Additionally new method required less amount of leaf sample for analysis of major metabolites and facilitates storage of samples until analysis. The freeze-dried method would be useful for high throughput analysis of large number of samples in shorter period without chemical deterioration starting from the point of harvest until usage. Hence, this method is more suitable for metabolite profiling of tea as well as other phenol rich plants.

  19. Preparation of tissue samples for X-ray fluorescence microscopy

    International Nuclear Information System (INIS)

    Chwiej, Joanna; Szczerbowska-Boruchowska, Magdalena; Lankosz, Marek; Wojcik, Slawomir; Falkenberg, Gerald; Stegowski, Zdzislaw; Setkowicz, Zuzanna

    2005-01-01

    As is well-known, trace elements, especially metals, play an important role in the pathogenesis of many disorders. The topographic and quantitative elemental analysis of pathologically changed tissues may shed some new light on processes leading to the degeneration of cells in the case of selected diseases. An ideal and powerful tool for such purpose is the Synchrotron Microbeam X-ray Fluorescence technique. It enables the carrying out of investigations of the elemental composition of tissues even at the single cell level. The tissue samples for histopathological investigations are routinely fixed and embedded in paraffin. The authors try to verify the usefulness of such prepared tissue sections for elemental analysis with the use of X-ray fluorescence microscopy. Studies were performed on rat brain samples. Changes in elemental composition caused by fixation in formalin or paraformaldehyde and embedding in paraffin were examined. Measurements were carried out at the bending magnet beamline L of the Hamburger Synchrotronstrahlungslabor HASYLAB in Hamburg. The decrease in mass per unit area of K, Br and the increase in P, S, Fe, Cu and Zn in the tissue were observed as a result of the fixation. For the samples embedded in paraffin, a lower level of most elements was observed. Additionally, for these samples, changes in the composition of some elements were not uniform for different analyzed areas of rat brain

  20. Preparation of tissue samples for X-ray fluorescence microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Chwiej, Joanna [Faculty of Physics and Applied Computer Science, AGH-University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland)]. E-mail: jchwiej@novell.ftj.agh.edu.pl; Szczerbowska-Boruchowska, Magdalena [Faculty of Physics and Applied Computer Science, AGH-University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland); Lankosz, Marek [Faculty of Physics and Applied Computer Science, AGH-University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland); Wojcik, Slawomir [Faculty of Physics and Applied Computer Science, AGH-University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland); Falkenberg, Gerald [Hamburger Synchrotronstrahlungslabor at Deutsches Elektronen-Synchrotron, Notkestr. 85, Hamburg (Germany); Stegowski, Zdzislaw [Faculty of Physics and Applied Computer Science, AGH-University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland); Setkowicz, Zuzanna [Department of Neuroanatomy, Institute of Zoology, Jagiellonian University, Ingardena 6, 30-060 Cracow (Poland)

    2005-12-15

    As is well-known, trace elements, especially metals, play an important role in the pathogenesis of many disorders. The topographic and quantitative elemental analysis of pathologically changed tissues may shed some new light on processes leading to the degeneration of cells in the case of selected diseases. An ideal and powerful tool for such purpose is the Synchrotron Microbeam X-ray Fluorescence technique. It enables the carrying out of investigations of the elemental composition of tissues even at the single cell level. The tissue samples for histopathological investigations are routinely fixed and embedded in paraffin. The authors try to verify the usefulness of such prepared tissue sections for elemental analysis with the use of X-ray fluorescence microscopy. Studies were performed on rat brain samples. Changes in elemental composition caused by fixation in formalin or paraformaldehyde and embedding in paraffin were examined. Measurements were carried out at the bending magnet beamline L of the Hamburger Synchrotronstrahlungslabor HASYLAB in Hamburg. The decrease in mass per unit area of K, Br and the increase in P, S, Fe, Cu and Zn in the tissue were observed as a result of the fixation. For the samples embedded in paraffin, a lower level of most elements was observed. Additionally, for these samples, changes in the composition of some elements were not uniform for different analyzed areas of rat brain.

  1. State of the art of environmentally friendly sample preparation approaches for determination of PBDEs and metabolites in environmental and biological samples: A critical review.

    Science.gov (United States)

    Berton, Paula; Lana, Nerina B; Ríos, Juan M; García-Reyes, Juan F; Altamirano, Jorgelina C

    2016-01-28

    Green chemistry principles for developing methodologies have gained attention in analytical chemistry in recent decades. A growing number of analytical techniques have been proposed for determination of organic persistent pollutants in environmental and biological samples. In this light, the current review aims to present state-of-the-art sample preparation approaches based on green analytical principles proposed for the determination of polybrominated diphenyl ethers (PBDEs) and metabolites (OH-PBDEs and MeO-PBDEs) in environmental and biological samples. Approaches to lower the solvent consumption and accelerate the extraction, such as pressurized liquid extraction, microwave-assisted extraction, and ultrasound-assisted extraction, are discussed in this review. Special attention is paid to miniaturized sample preparation methodologies and strategies proposed to reduce organic solvent consumption. Additionally, extraction techniques based on alternative solvents (surfactants, supercritical fluids, or ionic liquids) are also commented in this work, even though these are scarcely used for determination of PBDEs. In addition to liquid-based extraction techniques, solid-based analytical techniques are also addressed. The development of greener, faster and simpler sample preparation approaches has increased in recent years (2003-2013). Among green extraction techniques, those based on the liquid phase predominate over those based on the solid phase (71% vs. 29%, respectively). For solid samples, solvent assisted extraction techniques are preferred for leaching of PBDEs, and liquid phase microextraction techniques are mostly used for liquid samples. Likewise, green characteristics of the instrumental analysis used after the extraction and clean-up steps are briefly discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Collection and preparation of water samples for hydrogeochemical reconnaissance

    International Nuclear Information System (INIS)

    Baucom, E.I.; Ferguson, R.B.; Wallace, R.M.

    1977-01-01

    A method based on ion exchange and neutron activation analysis (NAA) was developed and field-tested to determine uranium over the range 0.02 to 10,000 ppb in natural water using a single procedure. Water samples are filtered in the field using a specially-designed one-liter filter apparatus pressurized to 40 psig with an inert gas. The filtered water is treated with a high purity, mixed cation-anion resin in the hydronium-hydroxide form. All ions are removed from solution under the strong driving force of the neutralization reaction. Anionic, cationic, and natural complexes of uranium can be concentrated with this method. Field tests showed greater than 95 percent recovery of 13 elements analyzed (including greater than 99 percent recovery of uranium) and greater than or equal to 90 percent recovery of 4 other elements. Uranium collected on the resin was quantitatively determined by NAA. Coefficient of variation for sampling plus analysis was less than 20 percent for samples containing more than 0.1 ppb uranium. Advantages of this method include: (1) wide dynamic range, (2) low detection limit for uranium (0.02 ppb), (3) high precision and accuracy, (4) relatively low cost, (5) high-yield recovery from low-level aqueous samples without risk of loss to containers, (6) decreased risk of significant sample contamination compared with other low-level methods, (7) production of stable samples suitable for retrievable storage, and(8) concentration of other ions that can be determined by NAA. This paper presents (1) background regarding development of procedures for sample collection and preparation, (2) results of development programs, (3) description of equipment and field procedures, and (4) preliminary conclusions regarding use of this technology for hydrogeochemical reconnaissance for uranium

  3. Comparison of Different Sample Preparation Protocols Reveals Lysis Buffer-Specific Extraction Biases in Gram-Negative Bacteria and Human Cells.

    Science.gov (United States)

    Glatter, Timo; Ahrné, Erik; Schmidt, Alexander

    2015-11-06

    We evaluated different in-solution and FASP-based sample preparation strategies for absolute protein quantification. Label-free quantification (LFQ) was employed to compare different sample preparation strategies in the bacterium Pseudomonas aeruginosa and human embryonic kidney cells (HEK), and organismal-specific differences in general performance and enrichment of specific protein classes were noted. The original FASP protocol globally enriched for most proteins in the bacterial sample, whereas the sodium deoxycholate in-solution strategy was more efficient with HEK cells. Although detergents were found to be highly suited for global proteome analysis, higher intensities were obtained for high-abundant nucleic acid-associated protein complexes, like the ribosome and histone proteins, using guanidine hydrochloride. Importantly, we show for the first time that the observable total proteome mass of a sample strongly depends on the sample preparation protocol, with some protocols resulting in a significant underestimation of protein mass due to incomplete protein extraction of biased protein groups. Furthermore, we demonstrate that some of the observed abundance biases can be overcome by incorporating a nuclease treatment step or, alternatively, a correction factor for complementary sample preparation approaches.

  4. The Effect of Prior Knowledge and Gender on Physics Achievement

    Science.gov (United States)

    Stewart, John; Henderson, Rachel

    2017-01-01

    Gender differences on the Conceptual Survey in Electricity and Magnetism (CSEM) have been extensively studied. Ten semesters (N=1621) of CSEM data is presented showing male students outperform female students on the CSEM posttest by 5 % (p qualitative in-semester test questions by 3 % (p = . 004), but no significant difference between male and female students was found on quantitative test questions. Male students enter the class with superior prior preparation in the subject and score 4 % higher on the CSEM pretest (p questions correctly (N=822), male and female differences on the CSEM and qualitative test questions cease to be significant. This suggests no intrinsic gender bias exists in the CSEM itself and that gender differences are the result of prior preparation measured by CSEM pretest score. Gender differences between male and female students increase with pretest score. Regression analyses are presented to further explore interactions between preparation, gender, and achievement.

  5. Sample preparation for accelerator mass spectrometry at the University of Washington

    International Nuclear Information System (INIS)

    Grootes, P.M.; Stuiver, M.; Farwell, G.W.; Schmidt, F.H.

    1981-01-01

    The adaptation of the University of Washington FN tandem Van de Graaff to accelerator mass spectrometry (AMS), as well as some of the results obtained, are described in another paper in this volume (Farwell et al., 1981). Here we discuss our experiences in preparing carbon and beryllium samples that give large and stable ion beams when used in our Extrion cesium sputter source with an inverted cesium beam geometry

  6. Robotic, MEMS-based Multi Utility Sample Preparation Instrument for ISS Biological Workstation, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This project will develop a multi-functional, automated sample preparation instrument for biological wet-lab workstations on the ISS. The instrument is based on a...

  7. Methodology for sample preparation and size measurement of commercial ZnO nanoparticles

    Directory of Open Access Journals (Sweden)

    Pei-Jia Lu

    2018-04-01

    Full Text Available This study discusses the strategies on sample preparation to acquire images with sufficient quality for size characterization by scanning electron microscope (SEM using two commercial ZnO nanoparticles of different surface properties as a demonstration. The central idea is that micrometer sized aggregates of ZnO in powdered forms need to firstly be broken down to nanosized particles through an appropriate process to generate nanoparticle dispersion before being deposited on a flat surface for SEM observation. Analytical tools such as contact angle, dynamic light scattering and zeta potential have been utilized to optimize the procedure for sample preparation and to check the quality of the results. Meanwhile, measurements of zeta potential values on flat surfaces also provide critical information and save lots of time and efforts in selection of suitable substrate for particles of different properties to be attracted and kept on the surface without further aggregation. This simple, low-cost methodology can be generally applied on size characterization of commercial ZnO nanoparticles with limited information from vendors. Keywords: Zinc oxide, Nanoparticles, Methodology

  8. Chromosomal differences between acute nonlymphocytic leukemia in patients with prior solid tumors and prior hematologic malignancies. A study of 14 cases with prior breast cancer

    International Nuclear Information System (INIS)

    Mamuris, Z.; Dumont, J.; Dutrillaux, B.; Aurias, A.

    1989-01-01

    A cytogenetic study of 14 patients with secondary acute nonlymphocytic leukemia (S-ANLL) with prior treatment for breast cancer is reported. The chromosomes recurrently involved in numerical or structural anomalies are chromosomes 7, 5, 17, and 11, in decreasing order of frequency. The distribution of the anomalies detected in this sample of patients is similar to that observed in published cases with prior breast or other solid tumors, though anomalies of chromosome 11 were not pointed out, but it significantly differs from that of the S-ANLL with prior hematologic malignancies. This difference is principally due to a higher involvement of chromosome 7 in patients with prior hematologic malignancies and of chromosomes 11 and 17 in patients with prior solid tumors. A genetic determinism involving abnormal recessive alleles located on chromosomes 5, 7, 11, and 17 uncovered by deletions of the normal homologs may be a cause of S-ANLL. The difference between patients with prior hematologic malignancies or solid tumors may be explained by different constitutional mutations of recessive genes in the two groups of patients

  9. Sample preparation methods for scanning electron microscopy of homogenized Al-Mg-Si billets: A comparative study

    International Nuclear Information System (INIS)

    Österreicher, Johannes Albert; Kumar, Manoj; Schiffl, Andreas; Schwarz, Sabine; Hillebrand, Daniel; Bourret, Gilles Remi

    2016-01-01

    Characterization of Mg-Si precipitates is crucial for optimizing the homogenization heat treatment of Al-Mg-Si alloys. Although sample preparation is key for high quality scanning electron microscopy imaging, most common methods lead to dealloying of Mg-Si precipitates. In this article we systematically evaluate different sample preparation methods: mechanical polishing, etching with various reagents, and electropolishing using different electrolytes. We demonstrate that the use of a nitric acid and methanol electrolyte for electropolishing a homogenized Al-Mg-Si alloy prevents the dissolution of Mg-Si precipitates, resulting in micrographs of higher quality. This preparation method is investigated in depth and the obtained scanning electron microscopy images are compared with transmission electron micrographs: the shape and size of Mg-Si precipitates appear very similar in either method. The scanning electron micrographs allow proper identification and measurement of the Mg-Si phases including needles with lengths of roughly 200 nm. These needles are β″ precipitates as confirmed by high resolution transmission electron microscopy. - Highlights: •Secondary precipitation in homogenized 6xxx Al alloys is crucial for extrudability. •Existing sample preparation methods for SEM are improvable. •Electropolishing with nitric acid/methanol yields superior quality in SEM. •The obtained micrographs are compared to TEM micrographs.

  10. Sample preparation methods for scanning electron microscopy of homogenized Al-Mg-Si billets: A comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Österreicher, Johannes Albert; Kumar, Manoj [LKR Light Metals Technologies Ranshofen, Austrian Institute of Technology, Postfach 26, 5282 Ranshofen (Austria); Schiffl, Andreas [Hammerer Aluminium Industries Extrusion GmbH, Lamprechtshausener Straße 69, 5282 Ranshofen (Austria); Schwarz, Sabine [University Service Centre for Transmission Electron Microscopy, Vienna University of Technology, Wiedner Hauptstr. 8-10, 1040 Wien (Austria); Hillebrand, Daniel [Hammerer Aluminium Industries Extrusion GmbH, Lamprechtshausener Straße 69, 5282 Ranshofen (Austria); Bourret, Gilles Remi, E-mail: gilles.bourret@sbg.ac.at [Department of Materials Science and Physics, University of Salzburg, Hellbrunner Straße 34, 5020 Salzburg (Austria)

    2016-12-15

    Characterization of Mg-Si precipitates is crucial for optimizing the homogenization heat treatment of Al-Mg-Si alloys. Although sample preparation is key for high quality scanning electron microscopy imaging, most common methods lead to dealloying of Mg-Si precipitates. In this article we systematically evaluate different sample preparation methods: mechanical polishing, etching with various reagents, and electropolishing using different electrolytes. We demonstrate that the use of a nitric acid and methanol electrolyte for electropolishing a homogenized Al-Mg-Si alloy prevents the dissolution of Mg-Si precipitates, resulting in micrographs of higher quality. This preparation method is investigated in depth and the obtained scanning electron microscopy images are compared with transmission electron micrographs: the shape and size of Mg-Si precipitates appear very similar in either method. The scanning electron micrographs allow proper identification and measurement of the Mg-Si phases including needles with lengths of roughly 200 nm. These needles are β″ precipitates as confirmed by high resolution transmission electron microscopy. - Highlights: •Secondary precipitation in homogenized 6xxx Al alloys is crucial for extrudability. •Existing sample preparation methods for SEM are improvable. •Electropolishing with nitric acid/methanol yields superior quality in SEM. •The obtained micrographs are compared to TEM micrographs.

  11. Preparation and analysis of standardized waste samples for Controlled Ecological Life Support Systems (CELSS)

    Science.gov (United States)

    Carden, J. L.; Browner, R.

    1982-01-01

    The preparation and analysis of standardized waste samples for controlled ecological life support systems (CELSS) are considered. Analysis of samples from wet oxidation experiments, the development of ion chromatographic techniques utilizing conventional high pressure liquid chromatography (HPLC) equipment, and an investigation of techniques for interfacing an ion chromatograph (IC) with an inductively coupled plasma optical emission spectrometer (ICPOES) are discussed.

  12. Contamination risk of stable isotope samples during milling.

    Science.gov (United States)

    Isaac-Renton, M; Schneider, L; Treydte, K

    2016-07-15

    Isotope analysis of wood is an important tool in dendrochronology and ecophysiology. Prior to mass spectrometry analysis, wood must be homogenized, and a convenient method involves a ball mill capable of milling samples directly in sample tubes. However, sample-tube plastic can contaminate wood during milling, which could lead to biological misinterpretations. We tested possible contamination of whole wood and cellulose samples during ball-mill homogenization for carbon and oxygen isotope measurements. We used a multi-factorial design with two/three steel milling balls, two sample amounts (10 mg, 40 mg), and two milling times (5 min, 10 min). We further analyzed abrasion by milling empty tubes, and measured the isotope ratios of pure contaminants. A strong risk exists for carbon isotope bias through plastic contamination: the δ(13) C value of polypropylene deviated from the control by -6.77‰. Small fibers from PTFE filter bags used during cellulose extraction also present a risk as the δ(13) C value of this plastic deviated by -5.02‰. Low sample amounts (10 mg) showed highest contamination due to increased abrasion during milling (-1.34‰), which is further concentrated by cellulose extraction (-3.38‰). Oxygen isotope measurements were unaffected. A ball mill can be used to homogenize samples within test tubes prior to oxygen isotope analysis, but not prior to carbon or radiocarbon isotope analysis. There is still a need for a fast, simple and contamination-free sample preparation procedure. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  13. Evaluating patients' preferences for type of bowel preparation prior to screening CT colonography: Convenience and comfort versus sensitivity and specificity

    International Nuclear Information System (INIS)

    Ghanouni, A.; Halligan, S.; Taylor, S.A.; Boone, D.; Plumb, A.; Wardle, J.; Wagner, C. von

    2013-01-01

    Aims: To explore the relative value patients place on comfort and convenience versus test sensitivity and specificity in the context of computed tomographic colonography (CTC) screening. Materials and methods: Twenty semi-structured interviews were carried out with patients attending hospital for radiological tests unrelated to CTC. Preferences for CTC with different types of bowel preparation for CTC screening were examined and interviews were analysed thematically. The discussion guide included separate sections on CTC, bowel preparation methods (non-, reduced- and full-laxative), and sensitivity and specificity. Patients were given information on each topic in turn and asked about their views and preferences during each section. Results: Following information about the test, patients' attitudes towards CTC were positive. Following information on bowel preparation, full-laxative purgation was anticipated to cause more adverse physical and lifestyle effects than using reduced- or non-laxative preparation. However, stated preferences were approximately equally divided, largely due to patients anticipating that non-laxative preparations would reduce test accuracy (because the bowel was not thoroughly cleansed). Following information on sensitivity and specificity (which supported patients' expectations), the predominant stated preference was for full-laxative preparation. Conclusions: Patients are likely to value test sensitivity and specificity over a more comfortable and convenient preparation. Future research should test this hypothesis on a larger sample

  14. Characterisation of Authentic Lignin Biorefinery Samples by Fourier Transform Infrared Spectroscopy and Determination of the Chemical Formula for Lignin

    DEFF Research Database (Denmark)

    Le, Duy Michael; Damgaard Nielsen, Anders; Sørensen, Hanne

    2017-01-01

    samples in situ with no prior purification and minimal sample preparation. Lignin chemical formulas and lignin Fourier transform infrared (FTIR) spectra were extracted from mixed spectra by filtering out signals from residual carbohydrates and minerals. From estimations of C, H and O and adjustment...

  15. Present state of tandem accelerator analysis facility of the National Institute for Environmental Studies. 2. Sample preparation

    Energy Technology Data Exchange (ETDEWEB)

    Kumamoto, Yuichiro; Shibata, Yasuyuki; Kume, Hiroshi; Tanaka, Atsushi; Yoneda, Minoru; Uehiro, Takashi; Morita, Masatoshi [National Inst. for Environmental Studies, Tsukuba, Ibaraki (Japan)

    1996-12-01

    An AMS exclusive apparatus constituted for a center of 5 MV of tandem accelerator (15SDH-2) was introduced to the National Institute for Environmental Studies on September, 1995. The incidental part of the apparatus is constituted by combining negative ion source for solid sample (MC-SNICS) with successive incidental system and combining negative ion source for gas sample (MGF-SNICS) with simultaneous incidental system. In this study, preparation of graphite target for testing of {sup 14}C at a temporary aim of supplying solid sample for MC-SNICS necessary to modulate the apparatus has been conducted. As a result, it was found that most of isotope fractionation on graphite formation from oxalic acid could be neglected. However, as it was said that efficiency of the graphite formation was largely changed with mixing with traced volume of gas such as sulfur dioxide and so on, future presumption is laid at investigation of such isotope fractionation effect on some samples except oxalic acid. In order to conduct contamination evaluation of 14-C at sample preparation, graphite preparation from organic matters and carbon dioxide obtained the fossil fuels without containing 14-C are exchanged in present research. (G.K.)

  16. A high-throughput robotic sample preparation system and HPLC-MS/MS for measuring urinary anatabine, anabasine, nicotine and major nicotine metabolites.

    Science.gov (United States)

    Wei, Binnian; Feng, June; Rehmani, Imran J; Miller, Sharyn; McGuffey, James E; Blount, Benjamin C; Wang, Lanqing

    2014-09-25

    Most sample preparation methods characteristically involve intensive and repetitive labor, which is inefficient when preparing large numbers of samples from population-scale studies. This study presents a robotic system designed to meet the sampling requirements for large population-scale studies. Using this robotic system, we developed and validated a method to simultaneously measure urinary anatabine, anabasine, nicotine and seven major nicotine metabolites: 4-Hydroxy-4-(3-pyridyl)butanoic acid, cotinine-N-oxide, nicotine-N-oxide, trans-3'-hydroxycotinine, norcotinine, cotinine and nornicotine. We analyzed robotically prepared samples using high-performance liquid chromatography (HPLC) coupled with triple quadrupole mass spectrometry in positive electrospray ionization mode using scheduled multiple reaction monitoring (sMRM) with a total runtime of 8.5 min. The optimized procedure was able to deliver linear analyte responses over a broad range of concentrations. Responses of urine-based calibrators delivered coefficients of determination (R(2)) of >0.995. Sample preparation recovery was generally higher than 80%. The robotic system was able to prepare four 96-well plate (384 urine samples) per day, and the overall method afforded an accuracy range of 92-115%, and an imprecision of labor-saving for sample preparation, making it efficient and practical for routine measurements in large population-scale studies such as the National Health and Nutrition Examination Survey (NHANES) and the Population Assessment of Tobacco and Health (PATH) study. Published by Elsevier B.V.

  17. Application of a Dual-Arm Robot in Complex Sample Preparation and Measurement Processes.

    Science.gov (United States)

    Fleischer, Heidi; Drews, Robert Ralf; Janson, Jessica; Chinna Patlolla, Bharath Reddy; Chu, Xianghua; Klos, Michael; Thurow, Kerstin

    2016-10-01

    Automation systems with applied robotics have already been established in industrial applications for many years. In the field of life sciences, a comparable high level of automation can be found in the areas of bioscreening and high-throughput screening. Strong deficits still exist in the development of flexible and universal fully automated systems in the field of analytical measurement. Reasons are the heterogeneous processes with complex structures, which include sample preparation and transport, analytical measurements using complex sensor systems, and suitable data analysis and evaluation. Furthermore, the use of nonstandard sample vessels with various shapes and volumes results in an increased complexity. The direct use of existing automation solutions from bioscreening applications is not possible. A flexible automation system for sample preparation, analysis, and data evaluation is presented in this article. It is applied for the determination of cholesterol in biliary endoprosthesis using gas chromatography-mass spectrometry (GC-MS). A dual-arm robot performs both transport and active manipulation tasks to ensure human-like operation. This general robotic concept also enables the use of manual laboratory devices and equipment and is thus suitable in areas with a high standardization grade. © 2016 Society for Laboratory Automation and Screening.

  18. Preparation of highly multiplexed small RNA sequencing libraries.

    Science.gov (United States)

    Persson, Helena; Søkilde, Rolf; Pirona, Anna Chiara; Rovira, Carlos

    2017-08-01

    MicroRNAs (miRNAs) are ~22-nucleotide-long small non-coding RNAs that regulate the expression of protein-coding genes by base pairing to partially complementary target sites, preferentially located in the 3´ untranslated region (UTR) of target mRNAs. The expression and function of miRNAs have been extensively studied in human disease, as well as the possibility of using these molecules as biomarkers for prognostication and treatment guidance. To identify and validate miRNAs as biomarkers, their expression must be screened in large collections of patient samples. Here, we develop a scalable protocol for the rapid and economical preparation of a large number of small RNA sequencing libraries using dual indexing for multiplexing. Combined with the use of off-the-shelf reagents, more samples can be sequenced simultaneously on large-scale sequencing platforms at a considerably lower cost per sample. Sample preparation is simplified by pooling libraries prior to gel purification, which allows for the selection of a narrow size range while minimizing sample variation. A comparison with publicly available data from benchmarking of miRNA analysis platforms showed that this method captures absolute and differential expression as effectively as commercially available alternatives.

  19. A novel sample preparation method to avoid influence of embedding medium during nano-indentation

    Science.gov (United States)

    Meng, Yujie; Wang, Siqun; Cai, Zhiyong; Young, Timothy M.; Du, Guanben; Li, Yanjun

    2013-02-01

    The effect of the embedding medium on the nano-indentation measurements of lignocellulosic materials was investigated experimentally using nano-indentation. Both the reduced elastic modulus and the hardness of non-embedded cell walls were found to be lower than those of the embedded samples, proving that the embedding medium used for specimen preparation on cellulosic material during nano-indentation can modify cell-wall properties. This leads to structural and chemical changes in the cell-wall constituents, changes that may significantly alter the material properties. Further investigation was carried out to detect the influence of different vacuum times on the cell-wall mechanical properties during the embedding procedure. Interpretation of the statistical analysis revealed no linear relationships between vacuum time and the mechanical properties of cell walls. The quantitative measurements confirm that low-viscosity resin has a rapid penetration rate early in the curing process. Finally, a novel sample preparation method aimed at preventing resin diffusion into lignocellulosic cell walls was developed using a plastic film to wrap the sample before embedding. This method proved to be accessible and straightforward for many kinds of lignocellulosic material, but is especially suitable for small, soft samples.

  20. MALDI (matrix assisted laser desorption ionization) Imaging Mass Spectrometry (IMS) of skin: Aspects of sample preparation.

    Science.gov (United States)

    de Macedo, Cristiana Santos; Anderson, David M; Schey, Kevin L

    2017-11-01

    MALDI (matrix assisted laser desorption ionization) Imaging Mass Spectrometry (IMS) allows molecular analysis of biological materials making possible the identification and localization of molecules in tissues, and has been applied to address many questions on skin pathophysiology, as well as on studies about drug absorption and metabolism. Sample preparation for MALDI IMS is the most important part of the workflow, comprising specimen collection and preservation, tissue embedding, cryosectioning, washing, and matrix application. These steps must be carefully optimized for specific analytes of interest (lipids, proteins, drugs, etc.), representing a challenge for skin analysis. In this review, critical parameters for MALDI IMS sample preparation of skin samples will be described. In addition, specific applications of MALDI IMS of skin samples will be presented including wound healing, neoplasia, and infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Effect of sample preparation method on quantification of polymorphs using PXRD.

    Science.gov (United States)

    Alam, Shahnwaz; Patel, Sarsvatkumar; Bansal, Arvind Kumar

    2010-01-01

    The purpose of this study was to improve the sensitivity and accuracy of quantitative analysis of polymorphic mixtures. Various techniques such as hand grinding and mixing (in mortar and pestle), air jet milling and ball milling for micronization of particle and mixing were used to prepare binary mixtures. Using these techniques, mixtures of form I and form II of clopidogrel bisulphate were prepared in various proportions from 0-5% w/w of form I in form II and subjected to x-ray powder diffraction analysis. In order to obtain good resolution in minimum time, step time and step size were varied to optimize scan rate. Among the six combinations, step size of 0.05 degrees with step time of 5 s demonstrated identification of maximum characteristic peaks of form I in form II. Data obtained from samples prepared using both grinding and mixing in ball mill showed good analytical sensitivity and accuracy compared to other methods. Powder x-ray diffraction method was reproducible, precise with LOD of 0.29% and LOQ of 0.91%. Validation results showed excellent correlation between actual and predicted concentration with R2 > 0.9999.

  2. Improved sample preparation for CE-LIF analysis of plant N-glycans.

    Science.gov (United States)

    Nagels, Bieke; Santens, Francis; Weterings, Koen; Van Damme, Els J M; Callewaert, Nico

    2011-12-01

    In view of glycomics studies in plants, it is important to have sensitive tools that allow one to analyze and characterize the N-glycans present on plant proteins in different species. Earlier methods combined plant-based sample preparations with CE-LIF N-glycan analysis but suffered from background contaminations, often resulting in non-reproducible results. This publication describes a reproducible and sensitive protocol for the preparation and analysis of plant N-glycans, based on a combination of the 'in-gel release method' and N-glycan analysis on a multicapillary DNA sequencer. Our protocol makes it possible to analyze plant N-glycans starting from low amounts of plant material with highly reproducible results. The developed protocol was validated for different plant species and plant cells. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Sample preparation for combined chemical analysis and bioassay application in water quality assessment

    NARCIS (Netherlands)

    Kolkman, A.; Schriks, M.; Brand, W; Bäuerlein, P.S.; van der Kooi, M.M.E.; van Doorn, R.H.; Emke, E.; Reus, A.; van der Linden, S.; de Voogt, P.; Heringa, M.B.

    2013-01-01

    The combination of in vitro bioassays and chemical screening can provide a powerful toolbox to determine biologically relevant compounds in water extracts. In this study, a sample preparation method is evaluated for the suitability for both chemical analysis and in vitro bioassays. A set of 39

  4. Quantitative Analysis of Heavy Metals in Water Based on LIBS with an Automatic Device for Sample Preparation

    International Nuclear Information System (INIS)

    Hu Li; Zhao Nanjing; Liu Wenqing; Meng Deshuo; Fang Li; Wang Yin; Yu Yang; Ma Mingjun

    2015-01-01

    Heavy metals in water can be deposited on graphite flakes, which can be used as an enrichment method for laser-induced breakdown spectroscopy (LIBS) and is studied in this paper. The graphite samples were prepared with an automatic device, which was composed of a loading and unloading module, a quantitatively adding solution module, a rapid heating and drying module and a precise rotating module. The experimental results showed that the sample preparation methods had no significant effect on sample distribution and the LIBS signal accumulated in 20 pulses was stable and repeatable. With an increasing amount of the sample solution on the graphite flake, the peak intensity at Cu I 324.75 nm accorded with the exponential function with a correlation coefficient of 0.9963 and the background intensity remained unchanged. The limit of detection (LOD) was calculated through linear fitting of the peak intensity versus the concentration. The LOD decreased rapidly with an increasing amount of sample solution until the amount exceeded 20 mL and the correlation coefficient of exponential function fitting was 0.991. The LOD of Pb, Ni, Cd, Cr and Zn after evaporating different amounts of sample solution on the graphite flakes was measured and the variation tendency of their LOD with sample solution amounts was similar to the tendency for Cu. The experimental data and conclusions could provide a reference for automatic sample preparation and heavy metal in situ detection. (paper)

  5. The automated sample preparation system MixMaster for investigation of volatile organic compounds with mid-infrared evanescent wave spectroscopy.

    Science.gov (United States)

    Vogt, F; Karlowatz, M; Jakusch, M; Mizaikoff, B

    2003-04-01

    For efficient development assessment, and calibration of new chemical analyzers a large number of independently prepared samples of target analytes is necessary. Whereas mixing units for gas analysis are readily available, there is a lack of instrumentation for accurate preparation of liquid samples containing volatile organic compounds (VOCs). Manual preparation of liquid samples containing VOCs at trace concentration levels is a particularly challenging and time consuming task. Furthermore, regularly scheduled calibration of sensors and analyzer systems demands for computer controlled automated sample preparation systems. In this paper we present a novel liquid mixing device enabling extensive measurement series with focus on volatile organic compounds, facilitating analysis of water polluted by traces of volatile hydrocarbons. After discussing the mixing system and control software, first results obtained by coupling with an FT-IR spectrometer are reported. Properties of the mixing system are assessed by mid-infrared attenuated total reflection (ATR) spectroscopy of methanol-acetone mixtures and by investigation of multicomponent samples containing volatile hydrocarbons such as 1,2,4-trichlorobenzene and tetrachloroethylene. Obtained ATR spectra are evaluated by principal component regression (PCR) algorithms. It is demonstrated that the presented sample mixing device provides reliable multicomponent mixtures with sufficient accuracy and reproducibility at trace concentration levels.

  6. Preparation and calibration by liquid scintillation of a sample of Cl 36

    International Nuclear Information System (INIS)

    Grau Malonda, A.; Los Arcos, J.M.; Rodriguez Barquero, L.; Suarez, C.

    1989-01-01

    A procedure to prepare a sample of Clorine 36, as Li 36 Cl, able to be measured by liquid scintillation counting, is described. The sample is chemically stable, with no variation of the quenching parameter up to 4 mg of LiCl per 15 ml of scintillator, keeps constant the counting efficiency for concentration higher than 40 μg of Li 36 Cl in that volume, and shows no deterioration over a 3 weed period. The Li 36 Cl solution has been standarized using the free parameter method with different volumes of toluene, PCS and Instagel, to an uncertainty of 0,3% (Author)

  7. Simple and Reproducible Sample Preparation for Single-Shot Phosphoproteomics with High Sensitivity

    DEFF Research Database (Denmark)

    Jersie-Christensen, Rosa R.; Sultan, Abida; Olsen, Jesper V

    2016-01-01

    The traditional sample preparation workflow for mass spectrometry (MS)-based phosphoproteomics is time consuming and usually requires multiple steps, e.g., lysis, protein precipitation, reduction, alkylation, digestion, fractionation, and phosphopeptide enrichment. Each step can introduce chemical...... artifacts, in vitro protein and peptide modifications, and contaminations. Those often result in sample loss and affect the sensitivity, dynamic range and accuracy of the mass spectrometric analysis. Here we describe a simple and reproducible phosphoproteomics protocol, where lysis, denaturation, reduction......, and alkylation are performed in a single step, thus reducing sample loss and increasing reproducibility. Moreover, unlike standard cell lysis procedures the cell harvesting is performed at high temperatures (99 °C) and without detergents and subsequent need for protein precipitation. Phosphopeptides are enriched...

  8. Ultrasound: a subexploited tool for sample preparation in metabolomics.

    Science.gov (United States)

    Luque de Castro, M D; Delgado-Povedano, M M

    2014-01-02

    Metabolomics, one of the most recently emerged "omics", has taken advantage of ultrasound (US) to improve sample preparation (SP) steps. The metabolomics-US assisted SP step binomial has experienced a dissimilar development that has depended on the area (vegetal or animal) and the SP step. Thus, vegetal metabolomics and US assisted leaching has received the greater attention (encompassing subdisciplines such as metallomics, xenometabolomics and, mainly, lipidomics), but also liquid-liquid extraction and (bio)chemical reactions in metabolomics have taken advantage of US energy. Also clinical and animal samples have benefited from US assisted SP in metabolomics studies but in a lesser extension. The main effects of US have been shortening of the time required for the given step, and/or increase of its efficiency or availability for automation; nevertheless, attention paid to potential degradation caused by US has been scant or nil. Achievements and weak points of the metabolomics-US assisted SP step binomial are discussed and possible solutions to the present shortcomings are exposed. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Efficient sample preparation method based on solvent-assisted dispersive solid-phase extraction for the trace detection of butachlor in urine and waste water samples.

    Science.gov (United States)

    Aladaghlo, Zolfaghar; Fakhari, Alireza; Behbahani, Mohammad

    2016-10-01

    In this work, an efficient sample preparation method termed solvent-assisted dispersive solid-phase extraction was applied. The used sample preparation method was based on the dispersion of the sorbent (benzophenone) into the aqueous sample to maximize the interaction surface. In this approach, the dispersion of the sorbent at a very low milligram level was achieved by inserting a solution of the sorbent and disperser solvent into the aqueous sample. The cloudy solution created from the dispersion of the sorbent in the bulk aqueous sample. After pre-concentration of the butachlor, the cloudy solution was centrifuged and butachlor in the sediment phase dissolved in ethanol and determined by gas chromatography with flame ionization detection. Under the optimized conditions (solution pH = 7.0, sorbent: benzophenone, 2%, disperser solvent: ethanol, 500 μL, centrifuged at 4000 rpm for 3 min), the method detection limit for butachlor was 2, 3 and 3 μg/L for distilled water, waste water, and urine sample, respectively. Furthermore, the preconcentration factor was 198.8, 175.0, and 174.2 in distilled water, waste water, and urine sample, respectively. Solvent-assisted dispersive solid-phase extraction was successfully used for the trace monitoring of butachlor in urine and waste water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Preparation of hard-to-make TEM samples using the FIB microscope; Praeparation von kompliziert herstellbaren TEM-Proben mit dem FIB-Mikroskop

    Energy Technology Data Exchange (ETDEWEB)

    Volkert, C.A. [Forschungszentrum Karlsruhe, Karlsruhe (Germany); Heiland, B.; Kauffmann, F. [Max-Planck-Inst. fuer Metallforschung, Stuttgart (Germany)

    2003-04-01

    The focused ion beam (FIB) microscope has become an important tool for the preparation of TEM samples over the last few years. Preparation of samples with the FIB has some specific advantages over conventional preparation methods which make it possible to prepare samples that would otherwise be difficult to prepare. The advantages that will be illustrated in this paper include: (1) precise selection of the sample volume to be prepared, (2) preparation of brittle materials, (3) preparation of highly stressed materials, and (4) preparation of composites composed of materials with widely differing properties. These advantages will be illustrated through several examples including cross-sectional preparation of nanocrystalline Ti-Si-N films, thermal barrier coatings, fatigued Al films, pecan shells, apatite, and metal whiskers. [German] Das Focused Ion Beam (FIB)-Mikroskop ist in den letzten Jahren zu einem wichtigen Werkzeug fuer die Praeparation von TEM-Proben geworden. Die Probenpraeparation mittels FIB hat gegenueber den konventionellen Praeparationsmethoden eine Reihe spezifischer Vorteile, die es ermoeglichen, Proben herzustellen, die ansonsten schwierig zu praeparieren waeren. Die in diesem Beitrag veranschaulichten Vorteile sind: (1) praezise Auswahl des zu praeparierenden Probenvolumens, (2) Praeparation von sproeden Materialien, (3) Praeparation von Materialien mit hohen Eigenspannungen, und (4) die Praeparation von Verbundwerkstoffen, die aus Komponenten mit stark unterschiedlichen Eigenschaften bestehen. Diese Vorteile werden anhand verschiedener Beispiele wie der Querschnittspraeparation von nanokristallinen Ti-Si-N-Schichten, thermischen Barriereschichten, Al-Schichten nach Ermuedung, Pekan-Nussschalen, Apatiten und Metallwhiskern veranschaulicht.

  11. Proteoglycan and proteome profiling of central human pulmonary fibrotic tissue utilizing miniaturized sample preparation

    DEFF Research Database (Denmark)

    Malmström, Johan; Larsen, Kristoffer; Hansson, Lennart

    2002-01-01

    -dimensional electrophoresis was interfaced to miniaturized sample preparation techniques using microcapillary extraction. Four protein groups were identified; cytoskeletal, adhesion, scavenger and metabolic proteins. These patient's proteomes showed a high degree of heterogeneity between patients but larger homogeneity...

  12. Membrane biofouling characterization: effects of sample preparation procedures on biofilm structure and the microbial community

    KAUST Repository

    Xue, Zheng

    2014-07-15

    Ensuring the quality and reproducibility of results from biofilm structure and microbial community analysis is essential to membrane biofouling studies. This study evaluated the impacts of three sample preparation factors (ie number of buffer rinses, storage time at 4°C, and DNA extraction method) on the downstream analysis of nitrifying biofilms grown on ultrafiltration membranes. Both rinse and storage affected biofilm structure, as suggested by their strong correlation with total biovolume, biofilm thickness, roughness and the spatial distribution of EPS. Significant variations in DNA yields and microbial community diversity were also observed among samples treated by different rinses, storage and DNA extraction methods. For the tested biofilms, two rinses, no storage and DNA extraction with both mechanical and chemical cell lysis from attached biofilm were the optimal sample preparation procedures for obtaining accurate information about biofilm structure, EPS distribution and the microbial community. © 2014 © 2014 Taylor & Francis.

  13. Degradation of hydrocarbons in soil samples analyzed within accepted analytical holding times

    International Nuclear Information System (INIS)

    Jackson, J.; Thomey, N.; Dietlein, L.F.

    1992-01-01

    Samples which are collected in conjunction with subsurface investigations at leaking petroleum storage tank sites and petroleum refineries are routinely analyzed for benzene, toluene, ethylbenzene, xylenes (BTEX), and total petroleum hydrocarbons (TPH). Water samples are preserved by the addition of hydrochloric acid and maintained at four degrees centigrade prior to analysis. This is done to prevent bacterial degradation of hydrocarbons. Chemical preservation is not presently performed on soil samples. Instead, the samples are cooled and maintained at four degrees centigrade. This study was done to measure the degree of degradation of hydrocarbons in soil samples which are analyzed within accepted holding times. Soil samples were collected and representative subsamples were prepared from the initial sample. Subsamples were analyzed in triplicate for BTEX and TPH throughout the length of the approved holding times to measure the extent of sample constituent degradation prior to analysis. Findings imply that for sandy soils, BTEX and TPH concentrations can be highly dependent upon the length of time which elapses between sample collection and analysis

  14. Error baseline rates of five sample preparation methods used to characterize RNA virus populations.

    Directory of Open Access Journals (Sweden)

    Jeffrey R Kugelman

    Full Text Available Individual RNA viruses typically occur as populations of genomes that differ slightly from each other due to mutations introduced by the error-prone viral polymerase. Understanding the variability of RNA virus genome populations is critical for understanding virus evolution because individual mutant genomes may gain evolutionary selective advantages and give rise to dominant subpopulations, possibly even leading to the emergence of viruses resistant to medical countermeasures. Reverse transcription of virus genome populations followed by next-generation sequencing is the only available method to characterize variation for RNA viruses. However, both steps may lead to the introduction of artificial mutations, thereby skewing the data. To better understand how such errors are introduced during sample preparation, we determined and compared error baseline rates of five different sample preparation methods by analyzing in vitro transcribed Ebola virus RNA from an artificial plasmid-based system. These methods included: shotgun sequencing from plasmid DNA or in vitro transcribed RNA as a basic "no amplification" method, amplicon sequencing from the plasmid DNA or in vitro transcribed RNA as a "targeted" amplification method, sequence-independent single-primer amplification (SISPA as a "random" amplification method, rolling circle reverse transcription sequencing (CirSeq as an advanced "no amplification" method, and Illumina TruSeq RNA Access as a "targeted" enrichment method. The measured error frequencies indicate that RNA Access offers the best tradeoff between sensitivity and sample preparation error (1.4-5 of all compared methods.

  15. Error baseline rates of five sample preparation methods used to characterize RNA virus populations

    Science.gov (United States)

    Kugelman, Jeffrey R.; Wiley, Michael R.; Nagle, Elyse R.; Reyes, Daniel; Pfeffer, Brad P.; Kuhn, Jens H.; Sanchez-Lockhart, Mariano; Palacios, Gustavo F.

    2017-01-01

    Individual RNA viruses typically occur as populations of genomes that differ slightly from each other due to mutations introduced by the error-prone viral polymerase. Understanding the variability of RNA virus genome populations is critical for understanding virus evolution because individual mutant genomes may gain evolutionary selective advantages and give rise to dominant subpopulations, possibly even leading to the emergence of viruses resistant to medical countermeasures. Reverse transcription of virus genome populations followed by next-generation sequencing is the only available method to characterize variation for RNA viruses. However, both steps may lead to the introduction of artificial mutations, thereby skewing the data. To better understand how such errors are introduced during sample preparation, we determined and compared error baseline rates of five different sample preparation methods by analyzing in vitro transcribed Ebola virus RNA from an artificial plasmid-based system. These methods included: shotgun sequencing from plasmid DNA or in vitro transcribed RNA as a basic “no amplification” method, amplicon sequencing from the plasmid DNA or in vitro transcribed RNA as a “targeted” amplification method, sequence-independent single-primer amplification (SISPA) as a “random” amplification method, rolling circle reverse transcription sequencing (CirSeq) as an advanced “no amplification” method, and Illumina TruSeq RNA Access as a “targeted” enrichment method. The measured error frequencies indicate that RNA Access offers the best tradeoff between sensitivity and sample preparation error (1.4−5) of all compared methods. PMID:28182717

  16. A "three-in-one" sample preparation method for simultaneous determination of B-group water-soluble vitamins in infant formula using VitaFast(®) kits.

    Science.gov (United States)

    Zhang, Heng; Lan, Fang; Shi, Yupeng; Wan, Zhi-Gang; Yue, Zhen-Feng; Fan, Fang; Lin, Yan-Kui; Tang, Mu-Jin; Lv, Jing-Zhang; Xiao, Tan; Yi, Changqing

    2014-06-15

    VitaFast(®) test kits designed for the microbiological assay in microtiter plate format can be applied to quantitative determination of B-group water-soluble vitamins such as vitamin B12, folic acid and biotin, et al. Compared to traditional microbiological methods, VitaFast(®) kits significantly reduce sample processing time and provide greater reliability, higher productivity and better accuracy. Recently, simultaneous determination of vitamin B12, folic acid and biotin in one sample is urgently required when evaluating the quality of infant formulae in our practical work. However, the present sample preparation protocols which are developed for individual test systems, are incompatible with simultaneous determination of several analytes. To solve this problem, a novel "three-in-one" sample preparation method is herein developed for simultaneous determination of B-group water-soluble vitamins using VitaFast(®) kits. The performance of this novel "three-in-one" sample preparation method was systematically evaluated through comparing with individual sample preparation protocols. The experimental results of the assays which employed "three-in-one" sample preparation method were in good agreement with those obtained from conventional VitaFast(®) extraction methods, indicating that the proposed "three-in-one" sample preparation method is applicable to the present three VitaFast(®) vitamin test systems, thus offering a promising alternative for the three independent sample preparation methods. The proposed new sample preparation method will significantly improve the efficiency of infant formulae inspection. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Determination of some organophosphorus pesticides in water and watermelon samples by microextraction prior to high-performance liquid chromatography.

    Science.gov (United States)

    Wang, Chun; Wu, Qiuhua; Wu, Chunxia; Wang, Zhi

    2011-11-01

    A novel method based on simultaneous liquid-liquid microextraction and carbon nanotube reinforced hollow fiber microporous membrane solid-liquid phase microextraction has been developed for the determination of six organophosphorus pesticides, i.e. isocarbophos, phosmet, parathion-methyl, triazophos, fonofos and phoxim, in water and watermelon samples prior to high-performance liquid chromatography (HPLC). Under the optimum conditions, the method shows a good linearity within a range of 1-200 ng/mL for water samples and 5-200 ng/g for watermelon samples, with the correlation coefficients (r) varying from 0.9990 to 0.9997 and 0.9986 to 0.9995, respectively. The limits of detection (LODs) were in the range between 0.1 and 0.3 ng/mL for water samples and between 1.0 and 1.5 ng/g for watermelon samples. The recoveries of the method at spiking levels of 5.0 and 50.0 ng/mL for water samples were between 85.4 and 100.8%, and at spiking levels of 5.0 and 50.0 ng/g for watermelon samples, they were between 82.6 and 92.4%, with the relative standard deviations (RSDs) varying from 4.5-6.9% and 5.2-7.4%, respectively. The results suggested that the developed method represents a simple, low-cost, high analytes preconcentration and excellent sample cleanup procedure for the determination of organophosphorus pesticides in water and watermelon samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Emanation thermal analysis. Principle of the method, preparation of samples and apparatus

    International Nuclear Information System (INIS)

    Balek, V.; Pentinghaus, H.J.

    1993-12-01

    Principles of the title method are outlined and the sample preparation procedures and instrumental designs are described. The publication is divided into chapters as follows: (I) Introduction; (II) Sample labelling: (II.1) Introducing parent nuclides as a source of inert gas in solid; Distribution of inert gas in the sample; (II.2) Introducing inert gases without parent nuclides (using the recoil effect of nuclear reactions and using ion bombardment); (II.3) Choice of the suitable labelling technique; (III) Equipment for emanation thermal analysis: (III.1) Inert gas detection and measurement of inert gas release rate; (III.2) System of carrier gas flow and stabilization; (IV) Determination of the optimal conditions for radon release rate measurement; (V) Example of ETA measurement. (P.A.). 1 tab., 10 figs. 5 refs

  19. Enhancing sample preparation capabilities for accelerator mass spectrometry radiocarbon and radiocalcium studies

    International Nuclear Information System (INIS)

    Taylor, R.E.

    1991-01-01

    With support provided by the LLNL Accelerator Mass Spectrometry Laboratory, the UCR Radiocarbon Laboratory continued its studies involving sample pretreatment and target preparation for both AMS radiocarbon ( 14 C) and radiocalcium ( 41 Ca) involving applications to archaeologically -- and paleoanthropologically- related samples. With regard to AMS 14 C-related studies, we have extended the development of a series of procedures which have, as their initial goal, the capability to combust several hundred microgram amounts of a chemically-pretreated organic sample and convert the resultant CO 2 to graphitic carbon which will consistently yield relatively high 13 C - ion currents and blanks which will yield, on a consistent basis, 14 C count rates at or below 0.20% modern, giving an 2 sigma age limit of >50,000 yr BP

  20. A redox equilibrator for the preparation of cytochrome oxidase of mixed valence states and intermediate compounds for x-ray synchrotron studies

    International Nuclear Information System (INIS)

    Chance, B.; Moore, J.; Powers, L.; Ching, Y.

    1982-01-01

    A redox titrator for the preparation of small volumes of highly concentrated biological samples of X-ray synchrotron studies provides for the redox equilibration at temperatures of 40 to -30 0 C. Anaerobic transfer directly to the X-ray sample chamber and mixing of an additional reagent just prior to freeze-trapping of the redox-equilibrated sample are provided

  1. Solid phase extraction for sample preparation in trace analysis of ionogenic compounds by capillary isotachophoresis

    International Nuclear Information System (INIS)

    Hutta, M.; Kaniansky, D.; Simunicova, E.; Zelenska, V.; Madajova, V.; Siskova, A.

    1992-01-01

    Various sorbents recommended for solid phase extraction (SPE) in sample preparation procedures were studied for use in combination with capillary isotachophoresis (ITP). They were very efficient in achieving trace concentration levels (low ppb, i.e., low parts per 10 9 ) for different types of ITP analytes present in environmental and biological matrices. A macroporous carbon sorbent was convenient for sample preparation in ITP analysis of short chain fatty acids (C 4 -C 9 ) in drinking water. Chelating sorbents based on hydroxyalkyl methacrylate matrix with salicylate, thioglycolate and 8-hydroxyquinolinate functionalities were found to be very suitable for preconcentration of heavy metals with an inherent sample clean-up. An octadecyl-bonded silica sorbent enabled in ITP a photometric detection of γ-aminobutyrate (labeled with a 2,4,6-trinitrophenyl group) at concentrations considerably lower than required for the determination of this amino acid in cerebrospinal fluid (∼5*10 -8 mol/l). (author) 34 refs.; 3 figs.; 1 tab

  2. Optimized cryo-focused ion beam sample preparation aimed at in situ structural studies of membrane proteins.

    Science.gov (United States)

    Schaffer, Miroslava; Mahamid, Julia; Engel, Benjamin D; Laugks, Tim; Baumeister, Wolfgang; Plitzko, Jürgen M

    2017-02-01

    While cryo-electron tomography (cryo-ET) can reveal biological structures in their native state within the cellular environment, it requires the production of high-quality frozen-hydrated sections that are thinner than 300nm. Sample requirements are even more stringent for the visualization of membrane-bound protein complexes within dense cellular regions. Focused ion beam (FIB) sample preparation for transmission electron microscopy (TEM) is a well-established technique in material science, but there are only few examples of biological samples exhibiting sufficient quality for high-resolution in situ investigation by cryo-ET. In this work, we present a comprehensive description of a cryo-sample preparation workflow incorporating additional conductive-coating procedures. These coating steps eliminate the adverse effects of sample charging on imaging with the Volta phase plate, allowing data acquisition with improved contrast. We discuss optimized FIB milling strategies adapted from material science and each critical step required to produce homogeneously thin, non-charging FIB lamellas that make large areas of unperturbed HeLa and Chlamydomonas cells accessible for cryo-ET at molecular resolution. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Highly simplified lateral flow-based nucleic acid sample preparation and passive fluid flow control

    Science.gov (United States)

    Cary, Robert E.

    2015-12-08

    Highly simplified lateral flow chromatographic nucleic acid sample preparation methods, devices, and integrated systems are provided for the efficient concentration of trace samples and the removal of nucleic acid amplification inhibitors. Methods for capturing and reducing inhibitors of nucleic acid amplification reactions, such as humic acid, using polyvinylpyrrolidone treated elements of the lateral flow device are also provided. Further provided are passive fluid control methods and systems for use in lateral flow assays.

  4. Highly simplified lateral flow-based nucleic acid sample preparation and passive fluid flow control

    Energy Technology Data Exchange (ETDEWEB)

    Cary, Robert B.

    2018-04-17

    Highly simplified lateral flow chromatographic nucleic acid sample preparation methods, devices, and integrated systems are provided for the efficient concentration of trace samples and the removal of nucleic acid amplification inhibitors. Methods for capturing and reducing inhibitors of nucleic acid amplification reactions, such as humic acid, using polyvinylpyrrolidone treated elements of the lateral flow device are also provided. Further provided are passive fluid control methods and systems for use in lateral flow assays.

  5. Sample preparation for liquid chromatographic analysis of phytochemicals in biological fluids.

    Science.gov (United States)

    Oh, Ju-Hee; Lee, Young-Joo

    2014-01-01

    Natural products have been used traditionally for the treatment and prevention of diseases for thousands of years and are nowadays consumed as dietary supplements and herbal medicine. To ensure the safe and effective use of these herbal products, information about bioavailability of active compounds in plasma or target tissues should be provided via validated analytical methods combined with appropriate sampling methods. To provide comprehensive and abridged information about sample preparation methods for the quantification of phytochemicals in biological samples using liquid chromatography analysis. Sample pre-treatment procedures used in analytical methods for in vivo pharmacokinetic studies of natural compounds or herbal medicines were reviewed. These were categorised according to the biological matrices (plasma, bile, urine, faeces and tissues) and sample clean-up processes (protein precipitation, liquid-liquid extraction and solid-phase extraction). Although various kinds of sample pre-treatment methods have been developed, liquid-liquid extraction is still widely used and solid-phase extraction is becoming increasingly popular because of its efficiency for extensive clean up of complex matrix samples. However, protein precipitation is still favoured due to its simplicity. Sample treatment for phytochemical analysis in biological fluids is an indispensable and critical step to obtain high quality results. This step could dominate the overall analytical process because both the duration of the process as well as the reliability of the data depend in large part on its efficiency. Thus, special attention should be given to the choice of a proper sample treatment method that targets analytes and their biomatrix. Copyright © 2013 John Wiley & Sons, Ltd.

  6. "On-off" switchable tool for food sample preparation: merging molecularly imprinting technology with stimuli-responsive blocks. Current status, challenges and highlighted applications.

    Science.gov (United States)

    Garcia, Raquel; Gomes da Silva, Marco D R; Cabrita, Maria João

    2018-01-01

    Sample preparation still remains a great challenge in the analytical workflow representing the most time-consuming and laborious step in analytical procedures. Ideally, sample pre-treatment procedures must be more selective, cheap, quick and environmental friendly. Molecular imprinting technology is a powerful tool in the development of highly selective sample preparation methodologies enabling to preconcentrate the analytes from a complex food matrix. Actually, the design and development of molecularly imprinted polymers-based functional materials that merge an enhancement of selectivity with a controllable and switchable mode of action by means of specific stimulus constitutes a hot research topic in the field of food analysis. Thus, combining the stimuli responsive mechanism and imprinting technology a new generation of materials are emerging. The application of these smart materials in sample preparation is in early stage of development, nevertheless new improvements will promote a new driven in the demanding field of food sample preparation. The new trends in the advancement of food sample preparation using these smart materials will be presented in this review and highlighted the most relevant applications in this particular area of knowledge. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Effects of sample preparation conditions on biomolecular solid-state NMR lineshapes

    Energy Technology Data Exchange (ETDEWEB)

    Jakeman, David L.; Mitchell, Dan J.; Shuttleworth, Wendy A.; Evans, Jeremy N.S. [Washington State University, Department of Biochemistry and Biophysics (United States)

    1998-10-15

    Sample preparation conditions with the 46 kDa enzyme complex of 5-enolpyruvyl-shikimate-3-phosphate (EPSP) synthase, shikimate-3-phosphate (S3P) and glyphosate (GLP) have been examined in an attempt to reduce linewidths in solid-state NMR spectra. The linewidths of {sup 13}P resonances associated with enzyme bound S3P and GLP in the lyophilized ternary complex have been reduced to 150 {+-} 12 Hz and 125 {+-} 7 Hz respectively, by a variety of methods involving additives and freezing techniques.

  8. Analysis of aroma compounds of Roselle by Dynamic Headspace Sampling using different preparation methods

    DEFF Research Database (Denmark)

    Juhari, Nurul Hanisah Binti; Varming, Camilla; Petersen, Mikael Agerlin

    2015-01-01

    The influence of different methods of sample preparation on the aroma profiles of dried Roselle (Hibiscus sabdariffa) was studied. Least amounts of aroma compounds were recovered by analysis of whole dry calyxes (WD) followed by ground dry (GD), blended together with water (BTW), and ground...

  9. A Bayesian Justification for Random Sampling in Sample Survey

    Directory of Open Access Journals (Sweden)

    Glen Meeden

    2012-07-01

    Full Text Available In the usual Bayesian approach to survey sampling the sampling design, plays a minimal role, at best. Although a close relationship between exchangeable prior distributions and simple random sampling has been noted; how to formally integrate simple random sampling into the Bayesian paradigm is not clear. Recently it has been argued that the sampling design can be thought of as part of a Bayesian's prior distribution. We will show here that under this scenario simple random sample can be given a Bayesian justification in survey sampling.

  10. Preparation of edible wild fruit and plant samples for analysis and some difficulties encountered in such analyses

    CSIR Research Space (South Africa)

    Strydom, ESP

    1969-12-01

    Full Text Available Freeze-dried samples are used for analysis and the methods of preparation of samples for freeze-drying are discussed. Freeze-drying has obvious advantages but has also a few minor disadvantages. Difficulties encountered in the determination of some...

  11. Use of high-intensity sonication for pre-treatment of biological tissues prior to multielemental analysis by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    De La Calle, Inmaculada; Costas, Marta; Cabaleiro, Noelia; Lavilla, Isela; Bendicho, Carlos

    2012-01-01

    In this work, two ultrasound-based procedures are developed for sample preparation prior to determination of P, K, Ca, Cr, Mn, Fe, Ni, Cu, Zn, As, Se and Sr in biological tissues by total reflection X-ray fluorescence spectrometry. Ultrasound-assisted extraction by means of a cup-horn sonoreactor and ultrasonic-probe slurry sampling were compared with a well-established procedure such as magnetic agitation slurry sampling. For that purpose, seven certified reference materials and different real samples of animal tissue were used. Similar accuracy and precision is obtained with the three sample preparation approaches tried. Limits of detection were dependent on both the sample matrix and the sample pre-treatment used, best values being achieved with ultrasound-assisted extraction. Advantages of ultrasound-assisted extraction include reduced sample handling, decreased contamination risks (neither addition of surfactants nor use of foreign objects inside the extraction vial), simpler background (no solid particles onto the sample carrier) and improved recovery for some elements such as P. A mixture of 10% v/v HNO 3 + 20–40% v/v HCl was suitable for extraction from biological tissues. - Highlights: ► We implement high-intensity sonication for pre-treatment of biological tissues. ► Multielemental analysis is performed by total reflection X-ray spectrometry. ► Ultrasound-based procedures are developed and compared to conventional slurry preparation. ► Features such as background, recovery and sample handling are favored by using ultrasonic extraction.

  12. Optimizing Frozen Sample Preparation for Laser Microdissection: Assessment of CryoJane Tape-Transfer System®.

    Directory of Open Access Journals (Sweden)

    Yelena G Golubeva

    Full Text Available Laser microdissection is an invaluable tool in medical research that facilitates collecting specific cell populations for molecular analysis. Diversity of research targets (e.g., cancerous and precancerous lesions in clinical and animal research, cell pellets, rodent embryos, etc. and varied scientific objectives, however, present challenges toward establishing standard laser microdissection protocols. Sample preparation is crucial for quality RNA, DNA and protein retrieval, where it often determines the feasibility of a laser microdissection project. The majority of microdissection studies in clinical and animal model research are conducted on frozen tissues containing native nucleic acids, unmodified by fixation. However, the variable morphological quality of frozen sections from tissues containing fat, collagen or delicate cell structures can limit or prevent successful harvest of the desired cell population via laser dissection. The CryoJane Tape-Transfer System®, a commercial device that improves cryosectioning outcomes on glass slides has been reported superior for slide preparation and isolation of high quality osteocyte RNA (frozen bone during laser dissection. Considering the reported advantages of CryoJane for laser dissection on glass slides, we asked whether the system could also work with the plastic membrane slides used by UV laser based microdissection instruments, as these are better suited for collection of larger target areas. In an attempt to optimize laser microdissection slide preparation for tissues of different RNA stability and cryosectioning difficulty, we evaluated the CryoJane system for use with both glass (laser capture microdissection and membrane (laser cutting microdissection slides. We have established a sample preparation protocol for glass and membrane slides including manual coating of membrane slides with CryoJane solutions, cryosectioning, slide staining and dissection procedure, lysis and RNA extraction

  13. Membrane biofouling characterization: effects of sample preparation procedures on biofilm structure and the microbial community

    KAUST Repository

    Xue, Zheng; Lu, Huijie; Liu, Wen-Tso

    2014-01-01

    Ensuring the quality and reproducibility of results from biofilm structure and microbial community analysis is essential to membrane biofouling studies. This study evaluated the impacts of three sample preparation factors (ie number of buffer rinses

  14. Effect of Preparation Method on Phase Formation Process and Structural and Magnetic Properties of Mn2.5Ge Samples

    Directory of Open Access Journals (Sweden)

    R. Sobhani

    2016-12-01

    Full Text Available In this paper, the phase formation process of Mn2.5Ge samples, prepared by mechanical alloying of Mn and Ge metal powders and annealing, has been studied. Results showed that in the milled samples the stable phase is Mn11Ge8 compound with orthorhombic structure and Pnam space group. The value of saturation magnetization increases by increasing milling time from 0.2 up to 1.95 (Am2Kg-1. The remanece of the samples increases by increasing the milling time while the coercivity decreases. Annealing of 15-hour milled sample results in disappearance of Mn and Ge and the formation of new phases of Mn3Ge, Mn5Ge2, Mn5Ge3 and Mn2.3Ge. Mn3Ge is the main phase with Do22 tetragonal structure and I4/mmm space group which is stable and dominant. The enhancement of saturation magnetization in the annealed sample is related to the formation of three new magnetic phases and the increase of coercivity is due to the presence of Mn3Ge compound with tetragonal structure. Studies were replicated on samples made by arc melting method to compare the results and to investigate the effect of the preparation method on phase formation and structural and magnetic properties of the materials. In these samples the saturation value was in range of 0.2 up to 1.95 (Am2Kg-1 depending on preparation methods. Rietveld refinement shows that Mn2.3Ge sample prepared from arc melted under 620oC anealing is single phase. Magnetic analysis of this sample show a saturation magnetization of 5.252(Am2Kg-1 and 0.005 T coercive field.

  15. Abstracts book of 4. Poznan Analytical Seminar on Modern Methods of Sample Preparation and Trace Amounts Determination of Elements

    International Nuclear Information System (INIS)

    1995-01-01

    The 4. Poznan Analytical Seminar on Modern Methods of Sample Preparation and Trace Amounts Determination of Elements has been held in Poznan 27-28 April 1995. The new versions of analytical methods have been presented for quantitative determination of trace elements in biological, environmental and geological materials. Also the number of special techniques for sample preparation enables achievement the best precision of analytical results have been shown and discussed

  16. Instrument and method for X-ray diffraction, fluorescence, and crystal texture analysis without sample preparation

    Science.gov (United States)

    Gendreau, Keith (Inventor); Martins, Jose Vanderlei (Inventor); Arzoumanian, Zaven (Inventor)

    2010-01-01

    An X-ray diffraction and X-ray fluorescence instrument for analyzing samples having no sample preparation includes a X-ray source configured to output a collimated X-ray beam comprising a continuum spectrum of X-rays to a predetermined coordinate and a photon-counting X-ray imaging spectrometer disposed to receive X-rays output from an unprepared sample disposed at the predetermined coordinate upon exposure of the unprepared sample to the collimated X-ray beam. The X-ray source and the photon-counting X-ray imaging spectrometer are arranged in a reflection geometry relative to the predetermined coordinate.

  17. Benchmarking sample preparation/digestion protocols reveals tube-gel being a fast and repeatable method for quantitative proteomics.

    Science.gov (United States)

    Muller, Leslie; Fornecker, Luc; Van Dorsselaer, Alain; Cianférani, Sarah; Carapito, Christine

    2016-12-01

    Sample preparation, typically by in-solution or in-gel approaches, has a strong influence on the accuracy and robustness of quantitative proteomics workflows. The major benefit of in-gel procedures is their compatibility with detergents (such as SDS) for protein solubilization. However, SDS-PAGE is a time-consuming approach. Tube-gel (TG) preparation circumvents this drawback as it involves directly trapping the sample in a polyacrylamide gel matrix without electrophoresis. We report here the first global label-free quantitative comparison between TG, stacking gel (SG), and basic liquid digestion (LD). A series of UPS1 standard mixtures (at 0.5, 1, 2.5, 5, 10, and 25 fmol) were spiked in a complex yeast lysate background. TG preparation allowed more yeast proteins to be identified than did the SG and LD approaches, with mean numbers of 1979, 1788, and 1323 proteins identified, respectively. Furthermore, the TG method proved equivalent to SG and superior to LD in terms of the repeatability of the subsequent experiments, with mean CV for yeast protein label-free quantifications of 7, 9, and 10%. Finally, known variant UPS1 proteins were successfully detected in the TG-prepared sample within a complex background with high sensitivity. All the data from this study are accessible on ProteomeXchange (PXD003841). © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Adapting RNAseq sample preparation for ISS

    Data.gov (United States)

    National Aeronautics and Space Administration — The primary innovation for this CIF will be the ability to accomplish library preparation of isolated RNA that will enable transcriptional (RNA instead of DNA)...

  19. Effort versus Reward: Preparing Samples for Fungal Community Characterization in High-Throughput Sequencing Surveys of Soils.

    Directory of Open Access Journals (Sweden)

    Zewei Song

    Full Text Available Next generation fungal amplicon sequencing is being used with increasing frequency to study fungal diversity in various ecosystems; however, the influence of sample preparation on the characterization of fungal community is poorly understood. We investigated the effects of four procedural modifications to library preparation for high-throughput sequencing (HTS. The following treatments were considered: 1 the amount of soil used in DNA extraction, 2 the inclusion of additional steps (freeze/thaw cycles, sonication, or hot water bath incubation in the extraction procedure, 3 the amount of DNA template used in PCR, and 4 the effect of sample pooling, either physically or computationally. Soils from two different ecosystems in Minnesota, USA, one prairie and one forest site, were used to assess the generality of our results. The first three treatments did not significantly influence observed fungal OTU richness or community structure at either site. Physical pooling captured more OTU richness compared to individual samples, but total OTU richness at each site was highest when individual samples were computationally combined. We conclude that standard extraction kit protocols are well optimized for fungal HTS surveys, but because sample pooling can significantly influence OTU richness estimates, it is important to carefully consider the study aims when planning sampling procedures.

  20. Glycan characterization of the NIST RM monoclonal antibody using a total analytical solution: From sample preparation to data analysis.

    Science.gov (United States)

    Hilliard, Mark; Alley, William R; McManus, Ciara A; Yu, Ying Qing; Hallinan, Sinead; Gebler, John; Rudd, Pauline M

    Glycosylation is an important attribute of biopharmaceutical products to monitor from development through production. However, glycosylation analysis has traditionally been a time-consuming process with long sample preparation protocols and manual interpretation of the data. To address the challenges associated with glycan analysis, we developed a streamlined analytical solution that covers the entire process from sample preparation to data analysis. In this communication, we describe the complete analytical solution that begins with a simplified and fast N-linked glycan sample preparation protocol that can be completed in less than 1 hr. The sample preparation includes labelling with RapiFluor-MS tag to improve both fluorescence (FLR) and mass spectral (MS) sensitivities. Following HILIC-UPLC/FLR/MS analyses, the data are processed and a library search based on glucose units has been included to expedite the task of structural assignment. We then applied this total analytical solution to characterize the glycosylation of the NIST Reference Material mAb 8761. For this glycoprotein, we confidently identified 35 N-linked glycans and all three major classes, high mannose, complex, and hybrid, were present. The majority of the glycans were neutral and fucosylated; glycans featuring N-glycolylneuraminic acid and those with two galactoses connected via an α1,3-linkage were also identified.

  1. Sample preparation of waste water to determine metallic contaminants by X-ray fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Gonzalez Olivos, Javier.

    1987-01-01

    Trace X-ray fluorescence spectroscopy analysis in liquid samples is preceded by sample preparation, which usually consists in the precipitation of the metallic ions and concentration over a thin cellulose filter. The samples preparation of waste water by this method is not efficient, due to the great amount of organic and insoluble matter that they contain. The purpose of this work was to determine the optimal value of pH in order to adsorbe all the insoluble matter contained in a waste water sample in the activated charcoal, so that the metallic ions could be precipitated and concentrated on a thin filter and determinated by X-ray fluorescence spectroscopy. A survey about the adsorption of some ions in activated charcoal in function of the pH was made for the following: Cr 3+ , Fe 3+ , Ni 2+ , Cu 2+ , Zn 2+ , Se 2+ , Hg 2+ , and Pb 2+ . It was observed that at pH 0, the ions are not adsorbed, but Cu 2+ and Zn 2+ are adsorbed in small amount; at pH 14, the ions are adsorbed, excluding Se, which is not adsorbed at any value of pH. If a waste water sample is treated at pH 0 with activated charcoal to adsorbe the organic and insoluble matter, most of the metallic ions are not adsorbed by the activated charcoal and could be precipitated with APDC (ammonium 1-pirrolidine dithio carbamate salt) and concentrated on a thin filter. The analysis of the metallic ions contained on the filter and those adsorbed in the activated charcoal by X-ray fluorescence spectroscopy, gave the total amount of the ions in the sample. (author)

  2. Example-driven manifold priors for image deconvolution.

    Science.gov (United States)

    Ni, Jie; Turaga, Pavan; Patel, Vishal M; Chellappa, Rama

    2011-11-01

    Image restoration methods that exploit prior information about images to be estimated have been extensively studied, typically using the Bayesian framework. In this paper, we consider the role of prior knowledge of the object class in the form of a patch manifold to address the deconvolution problem. Specifically, we incorporate unlabeled image data of the object class, say natural images, in the form of a patch-manifold prior for the object class. The manifold prior is implicitly estimated from the given unlabeled data. We show how the patch-manifold prior effectively exploits the available sample class data for regularizing the deblurring problem. Furthermore, we derive a generalized cross-validation (GCV) function to automatically determine the regularization parameter at each iteration without explicitly knowing the noise variance. Extensive experiments show that this method performs better than many competitive image deconvolution methods.

  3. HPLC/DAD determination of rosmarinic acid in Salvia officinalis: sample preparation optimization by factorial design

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Karina B. de [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Dept. de Farmacia; Oliveira, Bras H. de, E-mail: bho@ufpr.br [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Dept. de Quimica

    2013-01-15

    Sage (Salvia officinalis) contains high amounts of the biologically active rosmarinic acid (RA) and other polyphenolic compounds. RA is easily oxidized, and may undergo degradation during sample preparation for analysis. The objective of this work was to develop and validate an analytical procedure for determination of RA in sage, using factorial design of experiments for optimizing sample preparation. The statistically significant variables for improving RA extraction yield were determined initially and then used in the optimization step, using central composite design (CCD). The analytical method was then fully validated, and used for the analysis of commercial samples of sage. The optimized procedure involved extraction with aqueous methanol (40%) containing an antioxidant mixture (ascorbic acid and ethylenediaminetetraacetic acid (EDTA)), with sonication at 45 deg C for 20 min. The samples were then injected in a system containing a C{sub 18} column, using methanol (A) and 0.1% phosphoric acid in water (B) in step gradient mode (45A:55B, 0-5 min; 80A:20B, 5-10 min) with flow rate of 1.0 mL min-1 and detection at 330 nm. Using this conditions, RA concentrations were 50% higher when compared to extractions without antioxidants (98.94 {+-} 1.07% recovery). Auto-oxidation of RA during sample extraction was prevented by the use of antioxidants resulting in more reliable analytical results. The method was then used for the analysis of commercial samples of sage. (author)

  4. HPLC/DAD determination of rosmarinic acid in Salvia officinalis: sample preparation optimization by factorial design

    International Nuclear Information System (INIS)

    Oliveira, Karina B. de; Oliveira, Bras H. de

    2013-01-01

    Sage (Salvia officinalis) contains high amounts of the biologically active rosmarinic acid (RA) and other polyphenolic compounds. RA is easily oxidized, and may undergo degradation during sample preparation for analysis. The objective of this work was to develop and validate an analytical procedure for determination of RA in sage, using factorial design of experiments for optimizing sample preparation. The statistically significant variables for improving RA extraction yield were determined initially and then used in the optimization step, using central composite design (CCD). The analytical method was then fully validated, and used for the analysis of commercial samples of sage. The optimized procedure involved extraction with aqueous methanol (40%) containing an antioxidant mixture (ascorbic acid and ethylenediaminetetraacetic acid (EDTA)), with sonication at 45 deg C for 20 min. The samples were then injected in a system containing a C 18 column, using methanol (A) and 0.1% phosphoric acid in water (B) in step gradient mode (45A:55B, 0-5 min; 80A:20B, 5-10 min) with flow rate of 1.0 mL min−1 and detection at 330 nm. Using this conditions, RA concentrations were 50% higher when compared to extractions without antioxidants (98.94 ± 1.07% recovery). Auto-oxidation of RA during sample extraction was prevented by the use of antioxidants resulting in more reliable analytical results. The method was then used for the analysis of commercial samples of sage. (author)

  5. Application of acetone acetals as water scavengers and derivatization agents prior to the gas chromatographic analysis of polar residual solvents in aqueous samples.

    Science.gov (United States)

    van Boxtel, Niels; Wolfs, Kris; Van Schepdael, Ann; Adams, Erwin

    2015-12-18

    The sensitivity of gas chromatography (GC) combined with the full evaporation technique (FET) for the analysis of aqueous samples is limited due to the maximum tolerable sample volume in a headspace vial. Using an acetone acetal as water scavenger prior to FET-GC analysis proved to be a useful and versatile tool for the analysis of high boiling analytes in aqueous samples. 2,2-Dimethoxypropane (DMP) was used in this case resulting in methanol and acetone as reaction products with water. These solvents are relatively volatile and were easily removed by evaporation enabling sample enrichment leading to 10-fold improvement in sensitivity compared to the standard 10μL FET sample volumes for a selection of typical high boiling polar residual solvents in water. This could be improved even further if more sample is used. The method was applied for the determination of residual NMP in an aqueous solution of a cefotaxime analogue and proved to be considerably better than conventional static headspace (sHS) and the standard FET approach. The methodology was also applied to determine trace amounts of ethylene glycol (EG) in aqueous samples like contact lens fluids, where scavenging of the water would avoid laborious extraction prior to derivatization. During this experiment it was revealed that DMP reacts quantitatively with EG to form 2,2-dimethyl-1,3-dioxolane (2,2-DD) under the proposed reaction conditions. The relatively high volatility (bp 93°C) of 2,2-DD makes it possible to perform analysis of EG using the sHS methodology making additional derivatization reactions superfluous. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Evaluation of three sample preparation methods for the direct identification of bacteria in positive blood cultures by MALDI-TOF

    OpenAIRE

    Tanner, Hannah; Evans, Jason T.; Gossain, Savita; Hussain, Abid

    2017-01-01

    Background Patient mortality is significantly reduced by rapid identification of bacteria from sterile sites. MALDI-TOF can identify bacteria directly from positive blood cultures and multiple sample preparation methods are available. We evaluated three sample preparation methods and two MALDI-TOF score cut-off values. Positive blood culture bottles with organisms present in Gram stains were prospectively analysed by MALDI-TOF. Three lysis reagents (Saponin, SDS, and SepsiTyper lysis bufer) w...

  7. Waste minimization in analytical chemistry through innovative sample preparation techniques

    International Nuclear Information System (INIS)

    Smith, L. L.

    1998-01-01

    Because toxic solvents and other hazardous materials are commonly used in analytical methods, characterization procedures result in significant and costly amount of waste. We are developing alternative analytical methods in the radiological and organic areas to reduce the volume or form of the hazardous waste produced during sample analysis. For the radiological area, we have examined high-pressure, closed-vessel microwave digestion as a way to minimize waste from sample preparation operations. Heated solutions of strong mineral acids can be avoided for sample digestion by using the microwave approach. Because reactivity increases with pressure, we examined the use of less hazardous solvents to leach selected contaminants from soil for subsequent analysis. We demonstrated the feasibility of this approach by extracting plutonium from a NET reference material using citric and tartaric acids with microwave digestion. Analytical results were comparable to traditional digestion methods, while hazardous waste was reduced by a factor often. We also evaluated the suitability of other natural acids, determined the extraction performance on a wider variety of soil types, and examined the extraction efficiency of other contaminants. For the organic area, we examined ways to minimize the wastes associated with the determination of polychlorinated biphenyls (PCBs) in environmental samples. Conventional methods for analyzing semivolatile organic compounds are labor intensive and require copious amounts of hazardous solvents. For soil and sediment samples, we have a method to analyze PCBs that is based on microscale extraction using benign solvents (e.g., water or hexane). The extraction is performed at elevated temperatures in stainless steel cells containing the sample and solvent. Gas chromatography-mass spectrometry (GC/MS) was used to quantitate the analytes in the isolated extract. More recently, we developed a method utilizing solid-phase microextraction (SPME) for natural

  8. The utilisation of virtual images in patient information giving sessions for prostate cancer patients prior to radiotherapy

    International Nuclear Information System (INIS)

    Stewart-Lord, A.; Brown, M.; Noor, S.; Cook, J.; Jallow, O.

    2016-01-01

    The aim of the study was to explore the prostate patients' perceptions of a Virtual Environment for Radiotherapy Training (VERT) as an information giving resource prior to radiotherapy delivery. A survey design was used to determine the level of knowledge of those patients who attended VERT for a pre-treatment talk and identify the benefits and limitations of using VERT as pre-treatment information giving resource. Participants were invited to attend a VERT patient information session four weeks prior to their planning CT scan, and then complete a questionnaire two weeks after start of radiotherapy treatment. A sample of n = 38 patients were recruited over a five month data collection period. Results showed that patient perceptions on the use of VERT as information giving tool prior to radiotherapy treatment were very positive. The sessions enable patients to understand the potential impact of treatment volumes if the internal organ shape and location differed from that originally planned, enabling them to comply with radiotherapy treatment instructions. Additional key findings have demonstrated excellent levels of communication associated with the use of VERT emphasising the need for future patient preparation strategies to consider the use of virtual technology. - Highlights: • VERT pre-treatment information sessions were very helpful to patients. • Patients had a better understanding of what to expect during treatment. • The importance of following bowel and bladder treatment preparation was made clear. • The session helped to reduced patient anxiety and stress associated with treatment.

  9. Independent assessment of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) sample preparation quality: A novel statistical approach for quality scoring.

    Science.gov (United States)

    Kooijman, Pieter C; Kok, Sander J; Weusten, Jos J A M; Honing, Maarten

    2016-05-05

    Preparation of samples according to an optimized method is crucial for accurate determination of polymer sample characteristics by Matrix-Assisted Laser Desorption Ionization (MALDI) analysis. Sample preparation conditions such as matrix choice, cationization agent, deposition technique or even the deposition volume should be chosen to suit the sample of interest. Many sample preparation protocols have been developed and employed, yet finding the optimal sample preparation protocol remains a challenge. Because an objective comparison between the results of diverse protocols is not possible, "gut-feeling" or "good enough" is often decisive in the search for an optimum. This implies that sub-optimal protocols are used, leading to a loss of mass spectral information quality. To address this problem a novel analytical strategy based on MALDI imaging and statistical data processing was developed in which eight parameters were formulated to objectively quantify the quality of sample deposition and optimal MALDI matrix composition and finally sum up to an overall quality score of the sample deposition. These parameters can be established in a fully automated way using commercially available mass spectrometry imaging instruments without any hardware adjustments. With the newly developed analytical strategy the highest quality MALDI spots were selected, resulting in more reproducible and more valuable spectra for PEG in a variety of matrices. Moreover, our method enables an objective comparison of sample preparation protocols for any analyte and opens up new fields of investigation by presenting MALDI performance data in a clear and concise way. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Reproducibility of Serum Potassium Values in Serum From Blood Samples Stored for Increasing Times Prior to Centrifugation and Analysis.

    Science.gov (United States)

    Harper, Aaron; Lu, Chuanyong; Sun, Yi; Garcia, Rafael; Rets, Anton; Alexis, Herol; Saad, Heba; Eid, Ikram; Harris, Loretta; Marshall, Barbara; Tafani, Edlira; Pincus, Matthew R

    2016-05-01

    The goal of this work was to determine if immediate versus postponed centrifugation of samples affects the levels of serum potassium. Twenty participants donated normal venous blood that was collected in four serum separator tubes per donor, each of which was analyzed at 0, 1, 2, or 4 hr on the Siemens Advia 1800 autoanalyzer. Coefficients of variation (CVs) for potassium levels ranged from 0% to 7.6% with a mean of 3 ± 2%. ANOVA testing of the means for all 20 samples showed a P-value of 0.72 (>0.05) indicating that there was no statistically significant difference between the means of the samples at the four time points. Sixteen samples were found to have CVs that were ≤5%. Two samples showed increases of potassium from the reference range to levels higher than the upper reference limit, one of which had a 4-hr value that was within the reference or normal range (3.5-5 mEq/l). Overall, most samples were found to have reproducible levels of serum potassium. Serum potassium levels from stored whole blood collected in serum separator tubes are, for the most part, stable at room temperature for at least 4 hr prior to analysis. However, some samples can exhibit significant fluctuations of values. © 2015 Wiley Periodicals, Inc.

  11. Importance of sample preparation for molecular diagnosis of lyme borreliosis from urine.

    Science.gov (United States)

    Bergmann, A R; Schmidt, B L; Derler, A-M; Aberer, E

    2002-12-01

    Urine PCR has been used for the diagnosis of Borrelia burgdorferi infection in recent years but has been abandoned because of its low sensitivity and the irreproducibility of the results. Our study aimed to analyze technical details related to sample preparation and detection methods. Crucial for a successful urine PCR were (i) avoidance of the first morning urine sample; (ii) centrifugation at 36,000 x g; and (iii) the extraction method, with only DNAzol of the seven different extraction methods used yielding positive results with patient urine specimens. Furthermore, storage of frozen urine samples at -80 degrees C reduced the sensitivity of a positive urine PCR result obtained with samples from 72 untreated erythema migrans (EM) patients from 85% in the first 3 months to samples was proven by hybridization with a GEN-ETI-K-DEIA kit and for a 10 further positive amplicons by sequencing. By using all of these steps to optimize the urine PCR technique, B. burgdorferi infection could be diagnosed by using urine samples from EM patients with a sensitivity (85%) substantially better than that of serological methods (50%). This improved method could be of future importance as an additional laboratory technique for the diagnosis of unclear, unrecognized borrelia infections and diseases possibly related to Lyme borreliosis.

  12. Sample preparation procedure for PIXE elemental analysis on soft tissues

    International Nuclear Information System (INIS)

    Kubica, B.; Kwiatek, W.M.; Dutkiewicz, E.M.; Lekka, M.

    1997-01-01

    Trace element analysis is one of the most important field in analytical chemistry. There are several instrumental techniques which are applied for determinations of microscopic elemental content. The PIXE (Proton Induced X-ray Emission) technique is one of the nuclear techniques that is commonly applied for such purpose due to its multielemental analysis possibilities. The aim of this study was to establish the optimal conditions for target preparation procedure. In this paper two different approaches to the topic are presented and widely discussed. The first approach was the traditional pellet technique and the second one was mineralization procedure. For the analysis soft tissue such as liver was used. Some results are also presented on water samples. (author)

  13. An overview of sample preparation procedures for LC-MS multiclass antibiotic determination in environmental and food samples.

    Science.gov (United States)

    Moreno-Bondi, María Cruz; Marazuela, María Dolores; Herranz, Sonia; Rodriguez, Erika

    2009-10-01

    Antibiotics are a class of pharmaceuticals that are of great interest due to the large volumes of these substances that are consumed in both human and veterinary medicine, and due to their status as the agents responsible for bacterial resistance. They can be present in foodstuffs and in environmental samples as multicomponent chemical mixtures that exhibit a wide range of mechanisms of action. Moreover, they can be transformed into different metabolites by the action of microorganisms, as well as by other physical or chemical means, resulting in mixtures with higher ecotoxicities and risks to human health than those of the individual compounds. Therefore, there is growing interest in the availability of multiclass methods for the analysis of antimicrobial mixtures in environmental and food samples at very low concentrations. Liquid chromatography (LC) has become the technique of choice for multiclass analysis, especially when coupled to mass spectrometry (LC-MS) and tandem MS (LC-MS(2)). However, due to the complexity of the matrix, in most cases an extraction step for sample clean-up and preconcentration is required before analysis in order to achieve the required sensitivities. This paper reviews the most recent developments and applications of multiclass antimicrobial determination in environmental and food matrices, emphasizing the practical aspects of sample preparation for the simultaneous extraction of antimicrobials from the selected samples. Future trends in the application of LC-MS-based techniques to multiclass antibiotic analysis are also presented.

  14. A novel PFIB sample preparation protocol for correlative 3D X-ray CNT and FIB-TOF-SIMS tomography

    Energy Technology Data Exchange (ETDEWEB)

    Priebe, Agnieszka, E-mail: agnieszka.priebe@gmail.com [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France); Audoit, Guillaume; Barnes, Jean-Paul [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France)

    2017-02-15

    We present a novel sample preparation method that allows correlative 3D X-ray Computed Nano-Tomography (CNT) and Focused Ion Beam Time-Of-Flight Secondary Ion Mass Spectrometry (FIB-TOF-SIMS) tomography to be performed on the same sample. In addition, our invention ensures that samples stay unmodified structurally and chemically between the subsequent experiments. The main principle is based on modifying the topography of the X-ray CNT experimental setup before FIB-TOF-SIMS measurements by incorporating a square washer around the sample. This affects the distribution of extraction field lines and therefore influences the trajectories of secondary ions that are now guided more efficiently towards the detector. As the result, secondary ion detection is significantly improved and higher, i.e. statistically better, signals are obtained. - Highlights: • Novel sample preparation for correlative 3D X-ray CNT and FIB-TOF-SIMS is presented. • Two experiments are conducted on exactly the same sample without any modifications. • Introduction of a square washer around the sample leads to increased ion detection.

  15. Status report on sample preparation facilities for 14C analysis at the new CologneAMS center

    International Nuclear Information System (INIS)

    Rethemeyer, J.; Fülöp, R.-H.; Höfle, S.; Wacker, L.; Heinze, S.; Hajdas, I.; Patt, U.; König, S.; Stapper, B.; Dewald, A.

    2013-01-01

    The new AMS facility at University of Cologne (CologneAMS), Germany, was established in 2010 with the delivery of the HVE 6 MV Tandetron AMS, which will be used for 14 C, 26 Al, 36 Cl, 41 Ca, 129 I, 239 U and 244 Pu analyses. Parallel to the AMS installation the radiocarbon group has started to set up and test sample preparation methods and instruments for different materials. We present first results of reference and standard materials that have been processed and graphitized in our lab and measured at the ETH and CologneAMS facilities. The graphitization blank and its influence on small samples sizes processed with an automated graphitization system have been determined. Work on isolation of individual organic compounds with a preparative gas chromatography system has been started. The focus of our future work will be on reducing process blank levels and sample sizes as well as on the application of compound-specific radiocarbon analyses in (paleo-) environmental research.

  16. Solution preparation

    International Nuclear Information System (INIS)

    Seitz, M.G.

    1982-01-01

    Reviewed in this statement are methods of preparing solutions to be used in laboratory experiments to examine technical issues related to the safe disposal of nuclear waste from power generation. Each approach currently used to prepare solutions has advantages and any one approach may be preferred over the others in particular situations, depending upon the goals of the experimental program. These advantages are highlighted herein for three approaches to solution preparation that are currently used most in studies of nuclear waste disposal. Discussion of the disadvantages of each approach is presented to help a user select a preparation method for his particular studies. Also presented in this statement are general observations regarding solution preparation. These observations are used as examples of the types of concerns that need to be addressed regarding solution preparation. As shown by these examples, prior to experimentation or chemical analyses, laboratory techniques based on scientific knowledge of solutions can be applied to solutions, often resulting in great improvement in the usefulness of results

  17. Determination of protein carbonyls in plasma, cell extracts, tissue homogenates, isolated proteins: Focus on sample preparation and derivatization conditions.

    Science.gov (United States)

    Weber, Daniela; Davies, Michael J; Grune, Tilman

    2015-08-01

    Protein oxidation is involved in regulatory physiological events as well as in damage to tissues and is thought to play a key role in the pathophysiology of diseases and in the aging process. Protein-bound carbonyls represent a marker of global protein oxidation, as they are generated by multiple different reactive oxygen species in blood, tissues and cells. Sample preparation and stabilization are key steps in the accurate quantification of oxidation-related products and examination of physiological/pathological processes. This review therefore focuses on the sample preparation processes used in the most relevant methods to detect protein carbonyls after derivatization with 2,4-dinitrophenylhydrazine with an emphasis on measurement in plasma, cells, organ homogenates, isolated proteins and organelles. Sample preparation, derivatization conditions and protein handling are presented for the spectrophotometric and HPLC method as well as for immunoblotting and ELISA. An extensive overview covering these methods in previously published articles is given for researchers who plan to measure protein carbonyls in different samples. © 2015 Published by Elsevier Ltd.

  18. Novel sample preparation method for surfactant containing suppositories: effect of micelle formation on drug recovery.

    Science.gov (United States)

    Kalmár, Éva; Ueno, Konomi; Forgó, Péter; Szakonyi, Gerda; Dombi, György

    2013-09-01

    Rectal drug delivery is currently at the focus of attention. Surfactants promote drug release from the suppository bases and enhance the formulation properties. The aim of our work was to develop a sample preparation method for HPLC analysis for a suppository base containing 95% hard fat, 2.5% Tween 20 and 2.5% Tween 60. A conventional sample preparation method did not provide successful results as the recovery of the drug failed to fulfil the validation criterion 95-105%. This was caused by the non-ionic surfactants in the suppository base incorporating some of the drug, preventing its release. As guidance for the formulation from an analytical aspect, we suggest a well defined surfactant content based on the turbidimetric determination of the CMC (critical micelle formation concentration) in the applied methanol-water solvent. Our CMC data correlate well with the results of previous studies. As regards the sample preparation procedure, a study was performed of the effects of ionic strength and pH on the drug recovery with the avoidance of degradation of the drug during the procedure. Aminophenazone and paracetamol were used as model drugs. The optimum conditions for drug release from the molten suppository base were found to be 100 mM NaCl, 20-40 mM NaOH and a 30 min ultrasonic treatment of the final sample solution. As these conditions could cause the degradation of the drugs in the solution, this was followed by NMR spectroscopy, and the results indicated that degradation did not take place. The determined CMCs were 0.08 mM for Tween 20, 0.06 mM for Tween 60 and 0.04 mM for a combined Tween 20, Tween 60 system. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Investigation of CPD and HMDS Sample Preparation Techniques for Cervical Cells in Developing Computer-Aided Screening System Based on FE-SEM/EDX

    Science.gov (United States)

    Ng, Siew Cheok; Abu Osman, Noor Azuan

    2014-01-01

    This paper investigated the effects of critical-point drying (CPD) and hexamethyldisilazane (HMDS) sample preparation techniques for cervical cells on field emission scanning electron microscopy and energy dispersive X-ray (FE-SEM/EDX). We investigated the visualization of cervical cell image and elemental distribution on the cervical cell for two techniques of sample preparation. Using FE-SEM/EDX, the cervical cell images are captured and the cell element compositions are extracted for both sample preparation techniques. Cervical cell image quality, elemental composition, and processing time are considered for comparison of performances. Qualitatively, FE-SEM image based on HMDS preparation technique has better image quality than CPD technique in terms of degree of spread cell on the specimen and morphologic signs of cell deteriorations (i.e., existence of plate and pellet drying artifacts and membrane blebs). Quantitatively, with mapping and line scanning EDX analysis, carbon and oxygen element compositions in HMDS technique were higher than the CPD technique in terms of weight percentages. The HMDS technique has shorter processing time than the CPD technique. The results indicate that FE-SEM imaging, elemental composition, and processing time for sample preparation with the HMDS technique were better than CPD technique for cervical cell preparation technique for developing computer-aided screening system. PMID:25610902

  20. A novel sample preparation method to avoid influence of embedding medium during nano-indentation

    Science.gov (United States)

    Yujie Meng; Siqun Wang; Zhiyong Cai; Timothy M. Young; Guanben Du; Yanjun Li

    2012-01-01

    The effect of the embedding medium on the nano-indentation measurements of lignocellulosic materials was investigated experimentally using nano-indentation. Both the reduced elastic modulus and the hardness of nonembedded cell walls were found to be lower than those of the embedded samples, proving that the embedding medium used for specimen preparation on cellulosic...

  1. Evaluation of various techniques for the pretreatment of sewage sludges prior to trace metal analysis by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Smith, R.

    1983-01-01

    Six techniques were evaluated for their suitability for the pretreatment of dried sewage sludge prior to trace metal analysis by atomic absorption spectrophotometry. The evaluation comprised analysis of two prepared samples of dried sludge for aluminium, cadmium, chromium, copper, iron, lead, manganese, nickel and zinc, after the following pretreatment: dry ashing at 500 degrees Celsius followed by extraction with dilute hydrochloric acid; dry ashing at 500 degrees Celsius followed by extraction with aqua regia; nitric acid digestion followed by extraction with hydrochloric acid; extraction with aqua regia; ashing with magnesium nitrate solution at 550 degrees Celsius followed by digestion with hydrochloric acid and extraction with nitric acid; extraction with nitric acid. Procedures involving the use of perchloric acid, hydrofluoric acid and hydrogen peroxide were not considered for reasons of safety. Except in the case of aluminium the direct mineral acid digestion and/or extraction methods generally gave higher recoveries than the procedures incorporating an ashing step. Direct extraction of the sample with aqua regia was recommended as a rapid and simple general method of sample pretreatment prior to analysis for all the metals investigated except aluminium. For this metal, more drastic sample pretreatment will be required, for example fusion or hydrofluoric acid digestion

  2. Highly Simple Deep Eutectic Solvent Extraction of Manganese in Vegetable Samples Prior to Its ICP-OES Analysis.

    Science.gov (United States)

    Bağda, Esra; Altundağ, Hüseyin; Soylak, Mustafa

    2017-10-01

    In the present work, simple and sensitive extraction methods for selective determination of manganese have been successfully developed. The methods were based on solubilization of manganese in deep eutectic solvent medium. Three deep eutectic solvents with choline chloride (vitamin B4) and tartaric/oxalic/citric acids have been prepared. Extraction parameters were optimized with using standard reference material (1573a tomato leaves). The quantitative recovery values were obtained with 1.25 g/L sample to deep eutectic solvent (DES) volume, at 95 °C for 2 h. The limit of detection was found as 0.50, 0.34, and 1.23 μg/L for DES/tartaric, DES/oxalic, and DES/citric acid, respectively. At optimum conditions, the analytical signal was linear for the range of 10-3000 μg/L for all studied DESs with the correlation coefficient >0.99. The extraction methods were applied to different real samples such as basil herb, spinach, dill, and cucumber barks. The known amount of manganese was spiked to samples, and good recovery results were obtained.

  3. Use of alkaline or enzymatic sample pretreatment prior to characterization of gold nanoparticles in animal tissue by single-particle ICPMS

    DEFF Research Database (Denmark)

    Löschner, Katrin; Brabrand, Myung Suk Jung; Sloth, Jens Jørgen

    2014-01-01

    , not much is known about the applicability of spICPMS for determination of NPs in complex matrices such as biological tissues. In the present study, alkaline and enzymatic treatments were applied to solubilize spleen samples from rats, which had been administered 60-nm gold nanoparticles (Au......NPs) intravenously. The results showed that similar size distributions of AuNPs were obtained independent of the sample preparation method used. Furthermore, the quantitative results for AuNP mass concentration obtained with spICPMS following alkaline sample pretreatment coincided with results for total gold...... concentration obtained by conventional ICPMS analysis of acid-digested tissue. The recovery of AuNPs from enzymatically digested tissue, however, was approximately four times lower. Spiking experiments of blank spleen samples with AuNPs showed that the lower recovery was caused by an inferior transport...

  4. Trichlorosilane and silicon tetrachloride sample preparation for determination of boron, phosphorus and arsenic microelements

    International Nuclear Information System (INIS)

    Stolyarova, I.V.; Orlova, V.A.

    1995-01-01

    The conditions of sample preparation ensuring virtually complete elimination of boron, phosphorus, and arsenic losses are elaborated. Analysis procedures are proposed that involve hydrolysis in an autoclave for exothermic reactions and/or in an open reaction reservoir on frozen twice-distilled water with complexing-agent and oxidant solutionsd applied layer-by-layer, with the possible subsequent atomic-emission, extraction-spectrophotometric, or extraction-colorimetric determination of boron, phosphorus, and arsenic. The procedures improve the accuracy and precision of the results and reduce the duration of chemical preparation due to the quantitative preconcentration of boron, phosphorus, and arsenic; they almost completely eliminate the possibility of the formation of volatile fluoride forms of these elements. 11 refs.; 3 tabs

  5. Matrix removal in state of the art sample preparation methods for serum by charged aerosol detection and metabolomics-based LC-MS.

    Science.gov (United States)

    Schimek, Denise; Francesconi, Kevin A; Mautner, Anton; Libiseller, Gunnar; Raml, Reingard; Magnes, Christoph

    2016-04-07

    Investigations into sample preparation procedures usually focus on analyte recovery with no information provided about the fate of other components of the sample (matrix). For many analyses, however, and particularly those using liquid chromatography-mass spectrometry (LC-MS), quantitative measurements are greatly influenced by sample matrix. Using the example of the drug amitriptyline and three of its metabolites in serum, we performed a comprehensive investigation of nine commonly used sample clean-up procedures in terms of their suitability for preparing serum samples. We were monitoring the undesired matrix compounds using a combination of charged aerosol detection (CAD), LC-CAD, and a metabolomics-based LC-MS/MS approach. In this way, we compared analyte recovery of protein precipitation-, liquid-liquid-, solid-phase- and hybrid solid-phase extraction methods. Although all methods provided acceptable recoveries, the highest recovery was obtained by protein precipitation with acetonitrile/formic acid (amitriptyline 113%, nortriptyline 92%, 10-hydroxyamitriptyline 89%, and amitriptyline N-oxide 96%). The quantification of matrix removal by LC-CAD showed that the solid phase extraction method (SPE) provided the lowest remaining matrix load (48-123 μg mL(-1)), which is a 10-40 fold better matrix clean-up than the precipitation- or hybrid solid phase extraction methods. The metabolomics profiles of eleven compound classes, comprising 70 matrix compounds showed the trends of compound class removal for each sample preparation strategy. The collective data set of analyte recovery, matrix removal and matrix compound profile was used to assess the effectiveness of each sample preparation method. The best performance in matrix clean-up and practical handling of small sample volumes was showed by the SPE techniques, particularly HLB SPE. CAD proved to be an effective tool for revealing the considerable differences between the sample preparation methods. This detector can

  6. Miniaturized Sample Preparation and Rapid Detection of Arsenite in Contaminated Soil Using a Smartphone

    Directory of Open Access Journals (Sweden)

    Mohd Farhan Siddiqui

    2018-03-01

    Full Text Available Conventional methods for analyzing heavy metal contamination in soil and water generally require laboratory equipped instruments, complex procedures, skilled personnel and a significant amount of time. With the advancement in computing and multitasking performances, smartphone-based sensors potentially allow the transition of the laboratory-based analytical processes to field applicable, simple methods. In the present work, we demonstrate the novel miniaturized setup for simultaneous sample preparation and smartphone-based optical sensing of arsenic As(III in the contaminated soil. Colorimetric detection protocol utilizing aptamers, gold nanoparticles and NaCl have been optimized and tested on the PDMS-chip to obtain the high sensitivity with the limit of detection of 0.71 ppm (in the sample and a correlation coefficient of 0.98. The performance of the device is further demonstrated through the comparative analysis of arsenic-spiked soil samples with standard laboratory method, and a good agreement with a correlation coefficient of 0.9917 and the average difference of 0.37 ppm, are experimentally achieved. With the android application on the device to run the experiment, the whole process from sample preparation to detection is completed within 3 hours without the necessity of skilled personnel. The approximate cost of setup is estimated around 1 USD, weight 55 g. Therefore, the presented method offers the simple, rapid, portable and cost-effective means for onsite sensing of arsenic in soil. Combined with the geometric information inside the smartphones, the system will allow the monitoring of the contamination status of soils in a nation-wide manner.

  7. Miniaturized Sample Preparation and Rapid Detection of Arsenite in Contaminated Soil Using a Smartphone.

    Science.gov (United States)

    Siddiqui, Mohd Farhan; Kim, Soocheol; Jeon, Hyoil; Kim, Taeho; Joo, Chulmin; Park, Seungkyung

    2018-03-04

    Conventional methods for analyzing heavy metal contamination in soil and water generally require laboratory equipped instruments, complex procedures, skilled personnel and a significant amount of time. With the advancement in computing and multitasking performances, smartphone-based sensors potentially allow the transition of the laboratory-based analytical processes to field applicable, simple methods. In the present work, we demonstrate the novel miniaturized setup for simultaneous sample preparation and smartphone-based optical sensing of arsenic As(III) in the contaminated soil. Colorimetric detection protocol utilizing aptamers, gold nanoparticles and NaCl have been optimized and tested on the PDMS-chip to obtain the high sensitivity with the limit of detection of 0.71 ppm (in the sample) and a correlation coefficient of 0.98. The performance of the device is further demonstrated through the comparative analysis of arsenic-spiked soil samples with standard laboratory method, and a good agreement with a correlation coefficient of 0.9917 and the average difference of 0.37 ppm, are experimentally achieved. With the android application on the device to run the experiment, the whole process from sample preparation to detection is completed within 3 hours without the necessity of skilled personnel. The approximate cost of setup is estimated around 1 USD, weight 55 g. Therefore, the presented method offers the simple, rapid, portable and cost-effective means for onsite sensing of arsenic in soil. Combined with the geometric information inside the smartphones, the system will allow the monitoring of the contamination status of soils in a nation-wide manner.

  8. SUSPENSION OF THE PRIOR DISCIPLINARY INVESTIGATION ACCORDING TO LABOR LAW

    Directory of Open Access Journals (Sweden)

    Nicolae, GRADINARU

    2014-11-01

    Full Text Available In order to conduct the prior disciplinary investigation, the employee shall be convoked in writing by the person authorized by the employer to carry out the research, specifying the subject, date, time and place of the meeting. For this purpose the employer shall appoint a committee charged with conducting the prior disciplinary investigation. Prior disciplinary research cannot be done without the possibility of the accused person to defend himself. It would be an abuse of the employer to violate these provisions. Since the employee is entitled to formulate and sustain defence in proving innocence or lesser degree of guilt than imputed, it needs between the moment were disclosed to the employee and the one of performing the prior disciplinary investigation to be a reasonable term for the employee to be able to prepare a defence in this regard. The employee's failure to present at the convocation, without an objective reason entitles the employer to dispose the sanctioning without making the prior disciplinary investigation. The objective reason which makes the employee, that is subject to prior disciplinary investigation, unable to present to the preliminary disciplinary investigation, should be at the time of the investigation in question.

  9. Evaluation of FASP, SP3, and iST Protocols for Proteomic Sample Preparation in the Low Microgram Range.

    Science.gov (United States)

    Sielaff, Malte; Kuharev, Jörg; Bohn, Toszka; Hahlbrock, Jennifer; Bopp, Tobias; Tenzer, Stefan; Distler, Ute

    2017-11-03

    Efficient and reproducible sample preparation is a prerequisite for any robust and sensitive quantitative bottom-up proteomics workflow. Here, we performed an independent comparison between single-pot solid-phase-enhanced sample preparation (SP3), filter-aided sample preparation (FASP), and a commercial kit based on the in-StageTip (iST) method. We assessed their performance for the processing of proteomic samples in the low μg range using varying amounts of HeLa cell lysate (1-20 μg of total protein). All three workflows showed similar performances for 20 μg of starting material. When handling sample sizes below 10 μg, the number of identified proteins and peptides as well as the quantitative reproducibility and precision drastically dropped in case of FASP. In contrast, SP3 and iST provided high proteome coverage even in the low μg range. Even when digesting 1 μg of starting material, both methods still enabled the identification of over 3000 proteins and between 25 000 and 30 000 peptides. On average, the quantitative reproducibility between experimental replicates was slightly higher in case of SP3 (R 2 = 0.97 (SP3); R 2 = 0.93 (iST)). Applying SP3 toward the characterization of the proteome of FACS-sorted tumor-associated macrophages in the B16 tumor model enabled the quantification of 2965 proteins and revealed a "mixed" M1/M2 phenotype.

  10. Crystal orientation and sample preparation effects on sputtering and lattice damage in 100 keV self-irradiated copper

    International Nuclear Information System (INIS)

    Sprague, J.A.; Malmberg, P.R.; Reynolds, G.W.; Lambert, J.M.; Treado, P.A.; Vincenz, A.M.

    1987-01-01

    Sputtering yields and angular distributions have been measured as functions of sample preparation techniques and incident ion-beam orientation with respect to the crystal axes for 100 keV Cu-ion beams on Cu crystals and polycrystalline samples. The angular distributions have structure requiring an nth order cosine with two Gaussians superimposed to fit the data; strong peaking is observed near the backscatter direction. The yield is dependent on the beam to crystal and beam to polycrystalline-rod axis orientation, on the grain size of the polycrystals and on sample-preparation techniques. Yield measurements vary by as much as a factor of 4. Lattice-damage differences, measured with alpha particle channeling, are much smaller and seem to be saturated by fluences of the order of 1x10 16 /cm 2 . (orig.)

  11. Optimization of sample preparation variables for wedelolactone from Eclipta alba using Box-Behnken experimental design followed by HPLC identification.

    Science.gov (United States)

    Patil, A A; Sachin, B S; Shinde, D B; Wakte, P S

    2013-07-01

    Coumestan wedelolactone is an important phytocomponent from Eclipta alba (L.) Hassk. It possesses diverse pharmacological activities, which have prompted the development of various extraction techniques and strategies for its better utilization. The aim of the present study is to develop and optimize supercritical carbon dioxide assisted sample preparation and HPLC identification of wedelolactone from E. alba (L.) Hassk. The response surface methodology was employed to study the optimization of sample preparation using supercritical carbon dioxide for wedelolactone from E. alba (L.) Hassk. The optimized sample preparation involves the investigation of quantitative effects of sample preparation parameters viz. operating pressure, temperature, modifier concentration and time on yield of wedelolactone using Box-Behnken design. The wedelolactone content was determined using validated HPLC methodology. The experimental data were fitted to second-order polynomial equation using multiple regression analysis and analyzed using the appropriate statistical method. By solving the regression equation and analyzing 3D plots, the optimum extraction conditions were found to be: extraction pressure, 25 MPa; temperature, 56 °C; modifier concentration, 9.44% and extraction time, 60 min. Optimum extraction conditions demonstrated wedelolactone yield of 15.37 ± 0.63 mg/100 g E. alba (L.) Hassk, which was in good agreement with the predicted values. Temperature and modifier concentration showed significant effect on the wedelolactone yield. The supercritical carbon dioxide extraction showed higher selectivity than the conventional Soxhlet assisted extraction method. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  12. Blood plasma sample preparation method to determine thyroid hormone-disrupting compounds in Effect-Directed Analysis

    NARCIS (Netherlands)

    Simon, E.; Bytingsvik, J.; Jonker, W.; Leonards, P.E.G.; de Boer, J.; Jenssen, B.M.; Lie, E.; Aars, J.; Hamers, T.H.M.; Lamoree, M.H.

    2011-01-01

    A sample preparation method combining solid-phase extraction (SPE) and liquid-liquid extraction (LLE) was developed to be used in Effect-Directed Analysis (EDA) of blood plasma. Until now such a method was not available. It can be used for extraction of a broad range of thyroid hormone

  13. Sample Preparation Methodologies for In Situ Liquid and Gaseous Cell Analytical Transmission Electron Microscopy of Electropolished Specimens.

    Science.gov (United States)

    Zhong, Xiang Li; Schilling, Sibylle; Zaluzec, Nestor J; Burke, M Grace

    2016-12-01

    In recent years, an increasing number of studies utilizing in situ liquid and/or gaseous cell scanning/transmission electron microscopy (S/TEM) have been reported. Because of the difficulty in the preparation of suitable specimens, these environmental S/TEM studies have been generally limited to studies of nanoscale structured materials such as nanoparticles, nanowires, or sputtered thin films. In this paper, we present two methodologies which have been developed to facilitate the preparation of electron-transparent samples from conventional bulk metals and alloys for in situ liquid/gaseous cell S/TEM experiments. These methods take advantage of combining sequential electrochemical jet polishing followed by focused ion beam extraction techniques to create large electron-transparent areas for site-specific observation. As an example, we illustrate the application of this methodology for the preparation of in situ specimens from a cold-rolled Type 304 austenitic stainless steel sample, which was subsequently examined in both 1 atm of air as well as fully immersed in a H2O environment in the S/TEM followed by hyperspectral imaging. These preparation techniques can be successfully applied as a general procedure for a wide range of metals and alloys, and are suitable for a variety of in situ analytical S/TEM studies in both aqueous and gaseous environments.

  14. Sets of priors reflecting prior-data conflict and agreement

    NARCIS (Netherlands)

    Walter, G.M.; Coolen, F.P.A.; Carvalho, J.P.; Lesot, M.-J.; Kaymak, U.; Vieira, S.; Bouchon-Meunier, B.; Yager, R.R.

    2016-01-01

    Bayesian inference enables combination of observations with prior knowledge in the reasoning process. The choice of a particular prior distribution to represent the available prior knowledge is, however, often debatable, especially when prior knowledge is limited or data are scarce, as then

  15. Laboratory manual on sample preparation procedures for x-ray micro-analysis

    International Nuclear Information System (INIS)

    1997-01-01

    X-ray micro fluorescence is a non-destructive and sensitive method for studying the microscopic distribution of different elements in almost all kinds of samples. Since the beginning of this century, x-rays and electrons have been used for the analysis of many different kinds of material. Techniques which rely on electrons are mainly developed for microscopic studies, and are used in conventional Electron Microscopy (EM) or Scanning Electron Microscopy (SEM), while x-rays are widely used for chemical analysis at the microscopic level. The first chemical analysis by fluorescence spectroscopy using small x-ray beams was conducted in 1928 by Glockner and Schreiber. Since then much work has been devoted to developing different types of optical systems for focusing an x-ray beam, but the efficiency of these systems is still inferior to the conventional electron optical systems. However, even with a poor optical efficiency, the x-ray microbeam has many advantages compared with electron or proton induced x-ray emission methods. These include: The analyses are non-destructive, losses of mass are negligible, and due to the low thermal loading of x-rays, materials which may be thermally degraded can be analysed; Samples can be analysed in air, and no vacuum is required, therefore specimens with volatile components such as water in biological samples, can be imaged at normal pressure and temperature; No charging occurs during analysis and therefore coating of the sample with a conductive layer is not necessary; With these advantages, simpler sample preparation procedures including mounting and preservation can be used

  16. Influence of DC plasma modification on the selected properties and the geometrical surface structure of polylactide prior to autocatalytic metallization

    Energy Technology Data Exchange (ETDEWEB)

    Moraczewski, Krzysztof, E-mail: kmm@ukw.edu.pl [Kazimierz Wielki University, Chodkiewicza 30, 85-064 Bydgoszcz (Poland); Rytlewski, Piotr [Kazimierz Wielki University, Chodkiewicza 30, 85-064 Bydgoszcz (Poland); Malinowski, Rafał [Institute for Engineering of Polymer Materials and Dyes, Marii Skłodowskiej-Curie 55, 87-100 Toruń (Poland); Tracz, Adam [Centre for Molecular and Macromolecular Studies of the Polish Academy of Sciences, Sienkiewicza 112, 90-363 Łódź (Poland); Żenkiewicz, Marian [Institute for Engineering of Polymer Materials and Dyes, Marii Skłodowskiej-Curie 55, 87-100 Toruń (Poland)

    2015-03-01

    The paper presents the results of studies to determine the applicability of plasma modification in the process of polylactide (PLA) surface preparation prior to the autocatalytic metallization. The polylactide plasma modification was carried out in an oxygen or nitrogen chemistry. The samples were tested with the following methods: scanning electron microscopy (SEM), atomic force microscopy (AFM), goniometry and electron spectrophotometry (XPS). Scanning electron microscopy and atomic force microscopy images were demonstrated. The results of surface free energy calculations, performed based on the results of the contact angle measurements have been presented. The results of the qualitative (degree of oxidation or nitridation) and quantitative analysis of the chemical composition of the polylactide surface layer have also been described. The results of the studies show that the DC plasma modification performed in the proposed condition is a suitable as a method of surface preparation for the polylactide metallization. - Highlights: • We modified polylactide surface layer with plasma generated in oxygen or nitrogen. • We tested selected properties and surface structure of modified samples. • DC plasma modification can be used to prepare the PLA surface for metallization. • For better results metallization should be preceded by sonication process.

  17. Cyclization of the N-Terminal X-Asn-Gly Motif during Sample Preparation for Bottom-Up Proteomics

    DEFF Research Database (Denmark)

    Zhang, Xumin; Højrup, Peter

    2010-01-01

    We, herein, report a novel -17 Da peptide modification corresponding to an N-terminal cyclization of peptides possessing the N-terminal motif of X-Asn-Gly. The cyclization occurs spontaneously during sample preparation for bottom-up proteomics studies. Distinct from the two well-known N-terminal ......We, herein, report a novel -17 Da peptide modification corresponding to an N-terminal cyclization of peptides possessing the N-terminal motif of X-Asn-Gly. The cyclization occurs spontaneously during sample preparation for bottom-up proteomics studies. Distinct from the two well-known N......-terminal cyclizations, cyclization of N-terminal glutamine and S-carbamoylmethylcysteine, it is dependent on pH instead of [NH(4)(+)]. The data set from our recent study on large-scale N(α)-modified peptides revealed a sequence requirement for the cyclization event similar to the well-known deamidation of Asn to iso...

  18. An integrated sample preparation to determine coccidiostats and emerging Fusarium-mycotoxins in various poultry tissues with LC-MS/MS.

    Science.gov (United States)

    Jestoi, Marika; Rokka, Mervi; Peltonen, Kimmo

    2007-05-01

    The usefulness of an existing sample preparation technique used for ionophoric coccidiostats (lasalocid, monensin, salinomycin and narasin) was applied in the analysis of emerging Fusarium-mycotoxins beauvericin (BEA) and enniatins (ENNs) in poultry tissues (liver and meat). Also, maduramicin and liver as a new sample matrix was introduced. The developed methods were validated and applied for the determination of coccidiostats and BEA/ENNs in Finnish poultry tissues in 2004-2005. The validation parameters demonstrated that the integrated sample preparation technique is applicable to the parallel determination of these contaminants in poultry tissues. Of the samples analysed (276 meat and 43 liver), only trace levels of LAS, MON, SAL, NAR and MAD were detected in 7, 3, 5, 6 and 4% of the samples, respectively. Interestingly, for the first time, traces of BEA and ENNs could also be detected in animal tissues. BEA and ENNs A, A1, B and B1 were found in 2, 0.3, 0.6, 4 and 3% of the samples, respectively. The simultaneous presence of coccidiostats and mycotoxins was detected in three turkey samples in 2004.

  19. Preparation of modified magnetic nanoparticles as a sorbent for the preconcentration and determination of cadmium ions in food and environmental water samples prior to flame atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mirabi, Ali; Dalirandeh, Zeinab [Department of Chemistry, Qaemshahr Branch, Islamic Azad University, Qaemshahr (Iran, Islamic Republic of); Rad, Ali Shokuhi, E-mail: a.shokuhi@qaemshahriau.ac.ir [Department of Chemical Engineering, Qaemshahr Branch, Islamic Azad University, Qaemshahr (Iran, Islamic Republic of)

    2015-05-01

    A new method has been developed for the separation/preconcentration of trace level cadmium ions using diphenyl carbazone/sodium dodecyl sulfate immobilized on magnetic nanoparticle Fe{sub 3}O{sub 4} as a new sorbent SPE and their determination by flame atomic absorption spectrometry (FAAS). Synthesized nanoparticle was characterized by scanning electron microscope (SEM) and transmission electron microscope (TEM). Various influencing parameters on the separation and preconcentration of trace level cadmium ions such as, pH value, amount of nanoparticles, amount of diphenyl carbazone, condition of eluting solution, the effects of matrix ions were examined. The cadmium ions can be eluted from the modified magnetic nanoparticle using 1 mol L{sup −1} HCl as a desorption reagent. The detection limit of this method for cadmium was 3.71 ng ml{sup −1} and the R.S.D. was 0.503% (n=6). The advantages of this new method include rapidity, easy preparation of sorbents and a high concentration factor. The proposed method has been applied to the determination of Cd ions at trace levels in real samples such as, green tea, rice, tobacco, carrot, lettuce, ginseng, spice, tap water, river water, sea water with satisfactory results. - Highlights: • MNPs method is economical, simple, rapid and sensitive for trace analysis of Cd. • High preconcentration factor was obtained easily through this method. • A detection limit at ng mL{sup −1} level was achieved with 100.0 mL of sample. • This method provides good repeatability and extraction efficiency in a short time.

  20. Preparation of modified magnetic nanoparticles as a sorbent for the preconcentration and determination of cadmium ions in food and environmental water samples prior to flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Mirabi, Ali; Dalirandeh, Zeinab; Rad, Ali Shokuhi

    2015-01-01

    A new method has been developed for the separation/preconcentration of trace level cadmium ions using diphenyl carbazone/sodium dodecyl sulfate immobilized on magnetic nanoparticle Fe 3 O 4 as a new sorbent SPE and their determination by flame atomic absorption spectrometry (FAAS). Synthesized nanoparticle was characterized by scanning electron microscope (SEM) and transmission electron microscope (TEM). Various influencing parameters on the separation and preconcentration of trace level cadmium ions such as, pH value, amount of nanoparticles, amount of diphenyl carbazone, condition of eluting solution, the effects of matrix ions were examined. The cadmium ions can be eluted from the modified magnetic nanoparticle using 1 mol L −1 HCl as a desorption reagent. The detection limit of this method for cadmium was 3.71 ng ml −1 and the R.S.D. was 0.503% (n=6). The advantages of this new method include rapidity, easy preparation of sorbents and a high concentration factor. The proposed method has been applied to the determination of Cd ions at trace levels in real samples such as, green tea, rice, tobacco, carrot, lettuce, ginseng, spice, tap water, river water, sea water with satisfactory results. - Highlights: • MNPs method is economical, simple, rapid and sensitive for trace analysis of Cd. • High preconcentration factor was obtained easily through this method. • A detection limit at ng mL −1 level was achieved with 100.0 mL of sample. • This method provides good repeatability and extraction efficiency in a short time

  1. Study of exhaled breath condensate sample preparation for metabolomics analysis by LC-MS/MS in high resolution mode.

    Science.gov (United States)

    Fernández-Peralbo, M A; Calderón Santiago, M; Priego-Capote, F; Luque de Castro, M D

    2015-11-01

    Metabolomic analysis of exhaled breath condensate (EBC) requires an unavoidable sample preparation step because of the low concentration of its components, and potential cleanup for possible interferents. Sample preparation based on protein precipitation (PP), solid-phase extraction (SPE) by hydrophilic and lipophilic sorbents or lyophilization has demonstrated that the analytical sample from the last is largely the best because lyophilization allows reconstitution in a volume as small as required (preconcentration factors up to 80-times with respect to the original sample), thus doubling the number of detected compounds as compared with the other alternatives (47 versus 25). In addition, PP and/or SPE cleanup are unnecessary as no effect from the EBC components removed by these steps appears in the chromatograms. The total 49 EBC compounds tentatively identified and confirmed by MS/MS in this research include amino acids, fatty acids, fatty amides, fatty aldehydes, sphingoid bases, oxoanionic compounds, imidazoles, hydroxy acids and aliphatic acyclic acids. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Sensorimotor oscillations prior to speech onset reflect altered motor networks in adults who stutter

    Directory of Open Access Journals (Sweden)

    Anna-Maria Mersov

    2016-09-01

    Full Text Available Adults who stutter (AWS have demonstrated atypical coordination of motor and sensory regions during speech production. Yet little is known of the speech-motor network in AWS in the brief time window preceding audible speech onset. The purpose of the current study was to characterize neural oscillations in the speech-motor network during preparation for and execution of overt speech production in AWS using magnetoencephalography (MEG. Twelve AWS and twelve age-matched controls were presented with 220 words, each word embedded in a carrier phrase. Controls were presented with the same word list as their matched AWS participant. Neural oscillatory activity was localized using minimum-variance beamforming during two time periods of interest: speech preparation (prior to speech onset and speech execution (following speech onset. Compared to controls, AWS showed stronger beta (15-25Hz suppression in the speech preparation stage, followed by stronger beta synchronization in the bilateral mouth motor cortex. AWS also recruited the right mouth motor cortex significantly earlier in the speech preparation stage compared to controls. Exaggerated motor preparation is discussed in the context of reduced coordination in the speech-motor network of AWS. It is further proposed that exaggerated beta synchronization may reflect a more strongly inhibited motor system that requires a stronger beta suppression to disengage prior to speech initiation. These novel findings highlight critical differences in the speech-motor network of AWS that occur prior to speech onset and emphasize the need to investigate further the speech-motor assembly in the stuttering population.

  3. Sample preparation techniques based on combustion reactions in closed vessels - A brief overview and recent applications

    International Nuclear Information System (INIS)

    Flores, Erico M.M.; Barin, Juliano S.; Mesko, Marcia F.; Knapp, Guenter

    2007-01-01

    In this review, a general discussion of sample preparation techniques based on combustion reactions in closed vessels is presented. Applications for several kinds of samples are described, taking into account the literature data reported in the last 25 years. The operational conditions as well as the main characteristics and drawbacks are discussed for bomb combustion, oxygen flask and microwave-induced combustion (MIC) techniques. Recent applications of MIC techniques are discussed with special concern for samples not well digested by conventional microwave-assisted wet digestion as, for example, coal and also for subsequent determination of halogens

  4. Reference Priors for the General Location-Scale Model

    NARCIS (Netherlands)

    Fernández, C.; Steel, M.F.J.

    1997-01-01

    The reference prior algorithm (Berger and Bernardo 1992) is applied to multivariate location-scale models with any regular sampling density, where we establish the irrelevance of the usual assumption of Normal sampling if our interest is in either the location or the scale. This result immediately

  5. Structure and soft magnetic properties of the bulk samples prepared by compaction of the mixtures of Co-based and Fe-based powders

    International Nuclear Information System (INIS)

    Fuezer, J.; Bednarcik, J.; Kollar, P.; Roth, S.

    2007-01-01

    Ball milling of CoFeZrB ribbons and subsequent compaction of the resulting powders were used to prepare bulk amorphous samples. Further, two sets of powder samples were prepared by cryomilling of FeCuNbMoSiB alloy in amorphous and nanocrystalline state. Amorphous and nanocrystalline FeCuNbMoSiB powders were blended with CoFeZrB powder at different concentrations. Such powder mixtures were consolidated and several bulk nanocomposites have been synthesized. An addition of nanocrystalline or amorphous FeCuNbMoSiB powder to amorphous CoFeZrB powder caused a decrease of the magnetostriction of the resultant bulk samples, while the coercivity shows an opposite behavior. Our results show that the powder consolidation by hot pressing is an alternative method for the preparation of bulk metallic glasses, which are difficult to prepare by casting methods

  6. Simplified sample preparation in the simultaneous measurement of whole blood antimony, bismuth, manganese, and zinc by inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Haglock-Adler, Carrie J; Strathmann, Frederick G

    2015-02-01

    We developed and validated a simplified sample preparation for the analysis of antimony (Sb), bismuth (Bi), manganese (Mn), and zinc (Zn) in whole blood. This simplification included a reduction in sample volume, removal of a lengthy acidic digestion, and optimization of the internal standard. Measurement of Sb, Bi, Mn and Zn in whole blood was conducted using inductively coupled-plasma mass spectrometry. Method performance characteristics, including intra- and inter-assay imprecision, accuracy, linearity, AMR, sensitivity, carryover, sample stability and assay stability were determined in accordance with clinical laboratory standards. In addition, analytical and clinical recoveries were assessed to investigate comparability between goat blood matrix and pooled patient blood. Established assay performance characteristics included inter- and intra-assay imprecision samples, proficiency testing samples, and comparison to an outside reference laboratory. This method overcomes the laborious acidic heat digestion previously used and replaces it with a simplified sample preparation involving an alkaline dilution. The method requires minimal sample preparation with the dilution of alkaline diluent and is validated to quantify Sb and Bi from 1 to 25 μg/L, Mn from 1 to 80 μg/L, and Zn from 50 to 1500 μg/dL in whole blood. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. Spectrophotometric Determination of Lamotrigine in Pharmaceutical Preparations and Urine Samples Using Bromothymol Blue and Bromophenol Blue

    International Nuclear Information System (INIS)

    Najib, F.M.; Aziz, K.H.H.

    2013-01-01

    Two simple and sensitive spectrophotometric methods have been developed for the determination of the antiepileptic drug lamotrigine (LMT) in pharmaceutical preparations and urine samples. The methods are based on the interaction of LMT with two sulphonphthalein dyes, namely, bromothymol blue (BTB) and bromophenol blue (BPB) in dichloromethane (DCM) medium to form stable and yellow-colored ion-pairs with λ max 410 and 413 nm respectively. The ion-pair LMT-BPB has been extracted from aqueous solutions at pH 3.25±0.25 using DCM; while LMT-BTB ion-pair was directly prepared in DCM. Interferences from the compounds of the urine samples, in case of LMT-BPB were removed using a suppressing solution (S.S.) prepared from the salts of the interfering ions. In LMT-BTB method, the urine of normal person not taking LMT, was used as a blank to remove the effect of interferences. Under optimum conditions, the calibration curve of LMT-BTB was linear over the range of 1-12 μg.ml -1 , ε=1.97x10 4 L.mole -1 .cm -1 , r 2 = 0.9983, and D.L of 0.13 μg.ml -1 . The corresponding values for (LMT-BPB) ion-pair were 0.5-12 μg.ml -1 linear range, ε=1.92x10 4 , r 2 = 0.9980, and D.L= 0.24 μg.ml -1 . The stoichiometry of the ion-pairs were found to be 1:1, based on Jobs, mole ratio and slope ratio methods. The recoveries (%R) for both methods were in the range of 97-101.8 % and 95-97.1 % with RSD≤1.68 and 3.1 % respectively. For LMT- spiked urine samples, the recoveries were 98.5-106.6 % with RSD≤1.66 %. Interferences from phenobarbital and carbamazepine were in the range of 25-40 folds. Statistical comparison of the results with a published method using F and t-tests showed no significant differences between each of the two methods and the reported one at 95 % confidence level. A standard addition method, gave high accuracy with LMT-BPB method. The proposed methods were successfully applied for the determination of LMT in pharmaceutical preparation and urine samples. (author)

  8. On-site sampling and sample-preparation approach with a portable sampler based on hollow-fiber/graphene bars for the microextraction of nitrobenzene compounds in lake water.

    Science.gov (United States)

    Xing, Rongrong; Hu, Shuang; Chen, Xuan; Bai, Xiaohong; Feng, Meiqin

    2015-02-01

    A novel on-site sampling and sample-preparation approach was developed and evaluated in the present work. In this procedure, hollow-fiber/graphene bars (HF/GBs) were used for sampling and sample preparation. A handheld battery-operated electric egg beater was utilized to support the HF/GBs and stir the sample solution to facilitate extraction at the sampling site. Four nitrobenzene compounds (nitrobenzene, o-nitrophenol, m-nitrophenol, and p-nitrophenol) were used as model compounds. Several factors affecting performance, including types and amount of graphene used and extraction and desorption times, were investigated and optimized in the laboratory. Under optimized conditions, the enrichment factors of the four nitrobenzene compounds ranged from 46 to 69. Good linearities of 0.01-10 μg/mL with regression coefficients between 0.9917 and 0.9973 were obtained for all analytes. The LOD of the method was 0.3 ng/mL. Satisfactory recoveries (98-102%) and precision (1.0-5.8%) were also achieved. The ultrastructures and extraction mechanism of the HF/GBs were characterized and analyzed. The proposed approach coupled with high-performance liquid chromatography was successfully applied in the extraction and determination of trace nitrobenzene compounds in lake water. Experimental results showed that the approach is simple, convenient, rapid, and practical for routine environmental monitoring. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Solving probabilistic inverse problems rapidly with prior samples

    NARCIS (Netherlands)

    Käufl, Paul; Valentine, Andrew P.; de Wit, Ralph W.; Trampert, Jeannot

    2016-01-01

    Owing to the increasing availability of computational resources, in recent years the probabilistic solution of non-linear, geophysical inverse problems by means of sampling methods has become increasingly feasible. Nevertheless, we still face situations in which a Monte Carlo approach is not

  10. Comparison of Three Sample Preparation Procedures for the Quantification of L-Arginine, Asymmetric Dimethylarginine, and Symmetric Dimethylarginine in Human Plasma Using HPLC-FLD

    DEFF Research Database (Denmark)

    Schou-Pedersen, Anne Marie Voigt; Lykkesfeldt, Jens

    2018-01-01

    Increased asymmetric dimethylarginine (ADMA) in human plasma has been associated with reduced generation of nitric oxide, leading to atherosclerotic diseases. ADMA may therefore be an important biomarker for cardiovascular disease. In the present study, three sample preparation techniques were co...... sample preparation of human plasma samples before HPLC-FLD in providing important information regarding elevated ADMA concentrations.......Increased asymmetric dimethylarginine (ADMA) in human plasma has been associated with reduced generation of nitric oxide, leading to atherosclerotic diseases. ADMA may therefore be an important biomarker for cardiovascular disease. In the present study, three sample preparation techniques were...... compared regarding the quantification of L-arginine and ADMA in human plasma: (A) protein precipitation (PP) based on aqueous trichloroacetic acid (TCA), (B) PP using a mixture of ammonia and acetonitrile, and (C) solid-phase extraction (SPE). The samples were analysed by using high-performance liquid...

  11. Preparation and characterization of clay bonded high strength silica refractory by utilizing agriculture waste

    International Nuclear Information System (INIS)

    Bhardwaj, A.; Hossain, S.K.S.; Majh, M.R.

    2017-01-01

    Clay bonded silica refractory was prepared by utilizing agriculture waste called rice husk ash (RHA) and refractory grog. Various samples were prepared with different compositions based upon partial replacement of quartz by RHA. Rectangular samples were prepared by following semi dry process prior to pressing in a uniaxial hydraulic press and sintering at a temperature of 1200°C in air atmosphere. Various physical, mechanical and thermal characterizations were done like X-ray diffraction (XRD), scanning electron microscope (SEM), apparent porosity (AP), bulk density (BD), cold crushing strength (CCS), refractoriness and thermal conductivity measurement. The sample utilizing 30% of RHA was considered most optimum composition which produced cold crushing strength of 38MPa and thermal conductivity of 2.08W/mK at 800°C with a considerable good refractoriness. Enhancement in the mechanical as well as thermal properties may be considered as attributed to the amorphous silica which has reacted more easily and efficiently with other material surrounding giving rise to the densification and produced stable crystalline phase to the refractory material. These promising characteristics suggests that the RHA may lead to be used as a potential material for the preparation of clay bonded high strength silica refractories. [es

  12. Pressure-driven one-step solid phase-based on-chip sample preparation on a microfabricated plastic device and integration with flow-through polymerase chain reaction (PCR).

    Science.gov (United States)

    Tran, Hong Hanh; Trinh, Kieu The Loan; Lee, Nae Yoon

    2013-10-01

    In this study, we fabricate a monolithic poly(methylmethacrylate) (PMMA) microdevice on which solid phase-based DNA preparation and flow-through polymerase chain reaction (PCR) units were functionally integrated for one-step sample preparation and amplification operated by pressure. Chelex resin, which is used as a solid support for DNA preparation, can capture denatured proteins but releases DNA, and the purified DNA can then be used as a template in a subsequent amplification process. Using the PMMA microdevices, DNA was successfully purified from both Escherichia coli and human hair sample, and the plasmid vector inserted in E. coli and the D1S80 locus in human genomic DNA were successfully amplified from on-chip purified E. coli and human hair samples. Furthermore, the integration potential of the proposed sample preparation and flow-through PCR units was successfully demonstrate on a monolithic PMMA microdevice with a seamless flow, which could pave the way for a pressure-driven, simple one-step sample preparation and amplification with greatly decreased manufacture cost and enhanced device disposability. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Selectivity in the sample preparation for the analysis of drug residues in products of animal origin using LC-MS

    NARCIS (Netherlands)

    Berendsen, B.J.A.; Stolker, A.A.M.; Nielen, M.W.F.

    2013-01-01

    Sample preparation is critical in relation to analysis time, sample throughput and therefore analysis costs. Due to recent advances in liquid chromatography-mass spectrometry (LC-MS) instrumentation, the detection of many compounds within one run became possible, and methods for the simultaneous

  14. Sample preparation technique for transmission electron microscopy anodized Al-Li-SiC metal matrix composite

    International Nuclear Information System (INIS)

    Shahid, M.; Thomson, G.E.

    1997-01-01

    Along with improved mechanical properties, metal matrix composites (MMC) have a disadvantage of enhanced corrosion susceptibility in aggressive environments. Recent studies on corrosion behaviour of an Al-alloy 8090/SiC MMC, revealed considerably high corrosion rates of the MMC in near neutral solutions containing chloride ions. Anodizing is one of the potential surface treatment for the MMC to provide protective coating against corrosion. The surface and cross section of the anodized MMC can easily be observed using scanning electron microscope. The anodizing behaviour of the MMC can be understood further if the anodized cross section in examined under transmission electron microscope (TEM). However, it is relatively difficult to prepare small (3 mm diameter) electron transparent specimens of the MMC supporting an anodic film. In the present study a technique has been developed for preparing thin electron transparent specimens of the anodized MMC. This technique employed conventional ion beam thinning process but the preparation of small discs was a problem. A MMMC consisting of Al-alloy 8090 with 20 % (by weight) SiC particulate with an average size of 5 Mu m, was anodized and observed in TEM after preparing the samples using the above mentioned techniques. (author)

  15. Random template placement and prior information

    International Nuclear Information System (INIS)

    Roever, Christian

    2010-01-01

    In signal detection problems, one is usually faced with the task of searching a parameter space for peaks in the likelihood function which indicate the presence of a signal. Random searches have proven to be very efficient as well as easy to implement, compared e.g. to searches along regular grids in parameter space. Knowledge of the parameterised shape of the signal searched for adds structure to the parameter space, i.e., there are usually regions requiring to be densely searched while in other regions a coarser search is sufficient. On the other hand, prior information identifies the regions in which a search will actually be promising or may likely be in vain. Defining specific figures of merit allows one to combine both template metric and prior distribution and devise optimal sampling schemes over the parameter space. We show an example related to the gravitational wave signal from a binary inspiral event. Here the template metric and prior information are particularly contradictory, since signals from low-mass systems tolerate the least mismatch in parameter space while high-mass systems are far more likely, as they imply a greater signal-to-noise ratio (SNR) and hence are detectable to greater distances. The derived sampling strategy is implemented in a Markov chain Monte Carlo (MCMC) algorithm where it improves convergence.

  16. Comparison of Dilution, Filtration, and Microwave Digestion Sample Pretreatments in Elemental Profiling of Wine by ICP-MS.

    Science.gov (United States)

    Godshaw, Joshua; Hopfer, Helene; Nelson, Jenny; Ebeler, Susan E

    2017-09-25

    Wine elemental composition varies by cultivar, geographic origin, viticultural and enological practices, and is often used for authenticity validation. Elemental analysis of wine by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is challenging due to the potential for non-spectral interferences and plasma instability arising from organic matrix components. Sample preparation mitigates these interferences, however, conflicting recommendations of best practices in ICP-MS analysis of wine have been reported. This study compared direct dilution, microwave-assisted acid digestion, and two filtration sample pretreatments, acidification prior to filtration and filtration followed by acidification, in elemental profiling of one white and three red table wines by ICP-MS. Of 43 monitored isotopes, 37 varied by sample preparation method, with significantly higher results of 17 isotopes in the microwave-digested samples. Both filtration treatments resulted in lower results for 11 isotopes compared to the other methods. Finally, isotope dilution determination of copper based on natural abundances and the 63 Cu: 65 Cu instrument response ratio agreed with external calibration and confirmed a significant sample preparation effect. Overall, microwave digestion did not compare favorably, and direct dilution was found to provide the best compromise between ease of use and result accuracy and precision, although all preparation strategies were able to differentiate the wines.

  17. A comparison of sample preparation methods for extracting volatile organic compounds (VOCs) from equine faeces using HS-SPME.

    Science.gov (United States)

    Hough, Rachael; Archer, Debra; Probert, Christopher

    2018-01-01

    Disturbance to the hindgut microbiota can be detrimental to equine health. Metabolomics provides a robust approach to studying the functional aspect of hindgut microorganisms. Sample preparation is an important step towards achieving optimal results in the later stages of analysis. The preparation of samples is unique depending on the technique employed and the sample matrix to be analysed. Gas chromatography mass spectrometry (GCMS) is one of the most widely used platforms for the study of metabolomics and until now an optimised method has not been developed for equine faeces. To compare a sample preparation method for extracting volatile organic compounds (VOCs) from equine faeces. Volatile organic compounds were determined by headspace solid phase microextraction gas chromatography mass spectrometry (HS-SPME-GCMS). Factors investigated were the mass of equine faeces, type of SPME fibre coating, vial volume and storage conditions. The resultant method was unique to those developed for other species. Aliquots of 1000 or 2000 mg in 10 ml or 20 ml SPME headspace were optimal. From those tested, the extraction of VOCs should ideally be performed using a divinylbenzene-carboxen-polydimethysiloxane (DVB-CAR-PDMS) SPME fibre. Storage of faeces for up to 12 months at - 80 °C shared a greater percentage of VOCs with a fresh sample than the equivalent stored at - 20 °C. An optimised method for extracting VOCs from equine faeces using HS-SPME-GCMS has been developed and will act as a standard to enable comparisons between studies. This work has also highlighted storage conditions as an important factor to consider in experimental design for faecal metabolomics studies.

  18. Status report on sample preparation facilities for {sup 14}C analysis at the new CologneAMS center

    Energy Technology Data Exchange (ETDEWEB)

    Rethemeyer, J., E-mail: janet.rethemeyer@uni-koeln.de [Institute of Geology and Mineralogy, University of Cologne, 50674 Cologne (Germany); Fueloep, R.-H.; Hoefle, S. [Institute of Geology and Mineralogy, University of Cologne, 50674 Cologne (Germany); Wacker, L. [Ion Beam Physics, ETH Zuerich, 8093 Zuerich (Switzerland); Heinze, S. [Institute of Nuclear Physics, University of Cologne, 50674 Cologne (Germany); Hajdas, I. [Ion Beam Physics, ETH Zuerich, 8093 Zuerich (Switzerland); Patt, U.; Koenig, S.; Stapper, B. [Institute of Geology and Mineralogy, University of Cologne, 50674 Cologne (Germany); Dewald, A. [Institute of Nuclear Physics, University of Cologne, 50674 Cologne (Germany)

    2013-01-15

    The new AMS facility at University of Cologne (CologneAMS), Germany, was established in 2010 with the delivery of the HVE 6 MV Tandetron AMS, which will be used for {sup 14}C, {sup 26}Al, {sup 36}Cl, {sup 41}Ca, {sup 129}I, {sup 239}U and {sup 244}Pu analyses. Parallel to the AMS installation the radiocarbon group has started to set up and test sample preparation methods and instruments for different materials. We present first results of reference and standard materials that have been processed and graphitized in our lab and measured at the ETH and CologneAMS facilities. The graphitization blank and its influence on small samples sizes processed with an automated graphitization system have been determined. Work on isolation of individual organic compounds with a preparative gas chromatography system has been started. The focus of our future work will be on reducing process blank levels and sample sizes as well as on the application of compound-specific radiocarbon analyses in (paleo-) environmental research.

  19. Guideline for Sampling and Analysis of Tar and Particles in Biomass Producer Gases. Version 3.3

    Energy Technology Data Exchange (ETDEWEB)

    Neeft, J.P.A.; Knoef, H.A.M.; Zielke, U.; Sjoestroem, K.; Hasler, P.; Simell, P.A.; Dorrington, M.A.; Thomas, L.; Abatzoglou, N.; Deutch, S.; Greil, C.; Buffinga, G.J.; Brage, C.; Suomalainen, M.

    2002-07-01

    This Guideline provides a set of procedures for the measurement of organic contaminants and particles in producer gases from biomass gasifiers. The procedures are designed to cover different gasifier types (updraft or downdraft fixed bed or fluidised bed gasifiers), operating conditions (0 - 900C and 0.6-60 bars) and concentration ranges (1 mg/m{sub n}{sup 3} to 300 g/m{sub n}{sup 3}). The Guideline describes a modular sampling train, and a set of procedures, which include: planning and preparation of the sampling, sampling and post-sampling, analysis, calculations, error analysis and reporting. The modular sampling train consists of 4 modules. Module 1 is a preconditioning module for isokinetic sampling and gas cooling. Module 2 is a particle collection module including a heated filter. Module 3 is a tar collection module with a gas quench (optionally by circulating a liquid), impinger bottles and a backup adsorber. Module 4 is a volume-sampling module consisting of a pump, a rotameter, a gas flow meter and pressure and temperature indicators. The equipment and materials that are required for procuring this modular sampling train are given in the Guideline. The sampling procedures consist of a description for isokinetic sampling, a leakage test prior to sampling, the actual sampling and its duration, how the equipment is cleaned after the sampling, and how the samples are prepared and stored. Analysis of the samples is performed via three procedures. Prior to these procedures, the sample is prepared by Soxhlet extraction of the tars on the particle filter and by collection of all tars in one bulk solution. The first procedure describes the weighing of the particle filter to obtain the concentration of particles in the biomass producer gas. The bulk tar solution is used for two purposes: for determination of gravimetric tar and for analysis of individual compounds. The second procedure describes how to determine the gravimetric tar mass from the bulk solution. The

  20. Prior Elicitation, Assessment and Inference with a Dirichlet Prior

    Directory of Open Access Journals (Sweden)

    Michael Evans

    2017-10-01

    Full Text Available Methods are developed for eliciting a Dirichlet prior based upon stating bounds on the individual probabilities that hold with high prior probability. This approach to selecting a prior is applied to a contingency table problem where it is demonstrated how to assess the prior with respect to the bias it induces as well as how to check for prior-data conflict. It is shown that the assessment of a hypothesis via relative belief can easily take into account what it means for the falsity of the hypothesis to correspond to a difference of practical importance and provide evidence in favor of a hypothesis.

  1. Thin layer chromatographic analysis of some common over the counter (OTC cough–cold preparations

    Directory of Open Access Journals (Sweden)

    Manpreet Kaur Chahal

    2016-12-01

    Full Text Available In the present study, potential utility of thin layer chromatography to differentiate some common OTC cough–cold preparations was evaluated. Twenty solvent systems were examined from which a solvent systems A comprising methanol:ammonia in the ratio of 100:1.5 (v/v and B comprising chloroform:methanol in the ratio of 90:10 (v/v were found to be most suitable as it showed a high degree of separation of different components of these preparations. It was also found that iodine fuming technique is the best visualizing method for examining the TLC chromatograms of these drug samples prior to subsequent instrumental analysis.

  2. Testability evaluation using prior information of multiple sources

    Institute of Scientific and Technical Information of China (English)

    Wang Chao; Qiu Jing; Liu Guanjun; Zhang Yong

    2014-01-01

    Testability plays an important role in improving the readiness and decreasing the life-cycle cost of equipment. Testability demonstration and evaluation is of significance in measuring such testability indexes as fault detection rate (FDR) and fault isolation rate (FIR), which is useful to the producer in mastering the testability level and improving the testability design, and helpful to the consumer in making purchase decisions. Aiming at the problems with a small sample of testabil-ity demonstration test data (TDTD) such as low evaluation confidence and inaccurate result, a test-ability evaluation method is proposed based on the prior information of multiple sources and Bayes theory. Firstly, the types of prior information are analyzed. The maximum entropy method is applied to the prior information with the mean and interval estimate forms on the testability index to obtain the parameters of prior probability density function (PDF), and the empirical Bayesian method is used to get the parameters for the prior information with a success-fail form. Then, a parametrical data consistency check method is used to check the compatibility between all the sources of prior information and TDTD. For the prior information to pass the check, the prior credibility is calculated. A mixed prior distribution is formed based on the prior PDFs and the corresponding credibility. The Bayesian posterior distribution model is acquired with the mixed prior distribution and TDTD, based on which the point and interval estimates are calculated. Finally, examples of a flying control system are used to verify the proposed method. The results show that the proposed method is feasible and effective.

  3. Sources of variability in collection and preparation of paint and lead-coating samples.

    Science.gov (United States)

    Harper, S L; Gutknecht, W F

    2001-06-01

    Chronic exposure of children to lead (Pb) can result in permanent physiological impairment. Since surfaces coated with lead-containing paints and varnishes are potential sources of exposure, it is extremely important that reliable methods for sampling and analysis be available. The sources of variability in the collection and preparation of samples were investigated to improve the performance and comparability of methods and to ensure that data generated will be adequate for its intended use. Paint samples of varying sizes (areas and masses) were collected at different locations across a variety of surfaces including metal, plaster, concrete, and wood. A variety of grinding techniques were compared. Manual mortar and pestle grinding for at least 1.5 min and mechanized grinding techniques were found to generate similar homogenous particle size distributions required for aliquots as small as 0.10 g. When 342 samples were evaluated for sample weight loss during mortar and pestle grinding, 4% had 20% or greater loss with a high of 41%. Homogenization and sub-sampling steps were found to be the principal sources of variability related to the size of the sample collected. Analysis of samples from different locations on apparently identical surfaces were found to vary by more than a factor of two both in Pb concentration (mg cm-2 or %) and areal coating density (g cm-2). Analyses of substrates were performed to determine the Pb remaining after coating removal. Levels as high as 1% Pb were found in some substrate samples, corresponding to more than 35 mg cm-2 Pb. In conclusion, these sources of variability must be considered in development and/or application of any sampling and analysis methodologies.

  4. Drunkorexia: Calorie Restriction Prior to Alcohol Consumption among College Freshman

    Science.gov (United States)

    Burke, Sloane C.; Cremeens, Jennifer; Vail-Smith, Karen; Woolsey, Conrad

    2010-01-01

    Using a sample of 692 freshmen at a southeastern university, this study examined caloric restriction among students prior to planned alcohol consumption. Participants were surveyed for self-reported alcohol consumption, binge drinking, and caloric intake habits prior to drinking episodes. Results indicated that 99 of 695 (14%) of first year…

  5. Military Base Closures: Updated Status of Prior Base Realignments and Closures

    Science.gov (United States)

    As the Department of Defense (DOD) prepares for the 2005 base realignment and closure (BRAC) round, questions continue to be raised about the transfer and environmental cleanup of unneeded property arising from the prior four BRAC rounds and their impact on cost and savings and on local economies.

  6. Preparation and Loading Process of Single Crystalline Samples into a Gas Environmental Cell Holder for In Situ Atomic Resolution Scanning Transmission Electron Microscopic Observation.

    Science.gov (United States)

    Straubinger, Rainer; Beyer, Andreas; Volz, Kerstin

    2016-06-01

    A reproducible way to transfer a single crystalline sample into a gas environmental cell holder for in situ transmission electron microscopic (TEM) analysis is shown in this study. As in situ holders have only single-tilt capability, it is necessary to prepare the sample precisely along a specific zone axis. This can be achieved by a very accurate focused ion beam lift-out preparation. We show a step-by-step procedure to prepare the sample and transfer it into the gas environmental cell. The sample material is a GaP/Ga(NAsP)/GaP multi-quantum well structure on Si. Scanning TEM observations prove that it is possible to achieve atomic resolution at very high temperatures in a nitrogen environment of 100,000 Pa.

  7. Novel Sample Preparation Method for Safe and Rapid Detection of Bacillus anthracis Spores in Environmental Powders and Nasal Swabs

    OpenAIRE

    Luna, Vicki A.; King, Debra; Davis, Carisa; Rycerz, Tony; Ewert, Matthew; Cannons, Andrew; Amuso, Philip; Cattani, Jacqueline

    2003-01-01

    Bacillus anthracis spores have been used as a biological weapon in the United States. We wanted to develop a safe, rapid method of sample preparation that provided safe DNA for the detection of spores in environmental and clinical specimens. Our method reproducibly detects B. anthracis in samples containing

  8. Reproducibility of measurement of the environmental carbon-14 samples prepared by the gel suspension method

    International Nuclear Information System (INIS)

    Ohura, Hirotaka; Wakabayashi, Genichiro; Nakamura, Kouji; Okai, Tomio; Matoba, Masaru; Kakiuchi, Hideki; Momoshima, Noriyuki; Kawamura, Hidehisa.

    1997-01-01

    Simple liquid scintillation counting technique for the assay of 14 C in the environment was developed. This technique was done by using gel suspension method, in which sample preparation is very simple and requires no special equipments. The reproducibility of this technique was considered and it was shown that the gel suspension method had enough reproducibility to monitor the environmental 14 C. (author)

  9. Prior Sensitivity Analysis in Default Bayesian Structural Equation Modeling.

    Science.gov (United States)

    van Erp, Sara; Mulder, Joris; Oberski, Daniel L

    2017-11-27

    Bayesian structural equation modeling (BSEM) has recently gained popularity because it enables researchers to fit complex models and solve some of the issues often encountered in classical maximum likelihood estimation, such as nonconvergence and inadmissible solutions. An important component of any Bayesian analysis is the prior distribution of the unknown model parameters. Often, researchers rely on default priors, which are constructed in an automatic fashion without requiring substantive prior information. However, the prior can have a serious influence on the estimation of the model parameters, which affects the mean squared error, bias, coverage rates, and quantiles of the estimates. In this article, we investigate the performance of three different default priors: noninformative improper priors, vague proper priors, and empirical Bayes priors-with the latter being novel in the BSEM literature. Based on a simulation study, we find that these three default BSEM methods may perform very differently, especially with small samples. A careful prior sensitivity analysis is therefore needed when performing a default BSEM analysis. For this purpose, we provide a practical step-by-step guide for practitioners to conducting a prior sensitivity analysis in default BSEM. Our recommendations are illustrated using a well-known case study from the structural equation modeling literature, and all code for conducting the prior sensitivity analysis is available in the online supplemental materials. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  10. Automated microfluidic sample-preparation platform for high-throughput structural investigation of proteins by small-angle X-ray scattering

    DEFF Research Database (Denmark)

    Lafleur, Josiane P.; Snakenborg, Detlef; Nielsen, Søren Skou

    2011-01-01

    A new microfluidic sample-preparation system is presented for the structural investigation of proteins using small-angle X-ray scattering (SAXS) at synchrotrons. The system includes hardware and software features for precise fluidic control, sample mixing by diffusion, automated X-ray exposure...... control, UV absorbance measurements and automated data analysis. As little as 15 l of sample is required to perform a complete analysis cycle, including sample mixing, SAXS measurement, continuous UV absorbance measurements, and cleaning of the channels and X-ray cell with buffer. The complete analysis...

  11. Preparation of quality control samples in radioimmunoassay for thyroid stimulating hormone (TSH)

    International Nuclear Information System (INIS)

    Ali, O.M.

    2006-03-01

    To days, the radioimmunoassay is becomes the best technique to analysis different concentrations of substance, especially in medical and research laboratories. Although the specificity of RIA techniques, the quality controls must takes place to give good results as possible. In this dissertation i prepared quality control samples of thyroid stimulating hormone (TSH), to use it in RIA techniques and to control the reliability results of those laboratories which used these methods. We used China production kits of RIA method to determine the level of hormone (low-normal-high) concentration. Statistical parameters were used to drown the control chart of the mean to these data.(Author)

  12. Advantages of infrared transflection micro spectroscopy and paraffin-embedded sample preparation for biological studies

    Science.gov (United States)

    Yao, Jie; Li, Qian; Zhou, Bo; Wang, Dan; Wu, Rie

    2018-04-01

    Fourier-Transform Infrared micro-spectroscopy is an excellent method for biological analyses. In this paper, series metal coating films on ITO glass were prepared by the electrochemical method and the different thicknesses of paraffin embedding rat's brain tissue on the substrates were studied by IR micro-spetroscopy in attenuated total reflection (ATR) mode and transflection mode respectively. The Co-Ni-Cu alloy coating film with low cost is good reflection substrates for the IR analysis. The infrared microscopic transflection mode needs not to touch the sample at all and can get the IR spectra with higher signal to noise ratios. The Paraffin-embedding method allows tissues to be stored for a long time for re-analysis to ensure the traceability of the sample. Also it isolates the sample from the metal and avoids the interaction of biological tissue with the metals. The best thickness of the tissues is 4 μm.

  13. Beer as colon lavage preparation

    International Nuclear Information System (INIS)

    Kinnunen, J.; Linden, H.; Pietilae, J.; Juutilainen, T.

    1987-01-01

    Six patients received beer preparation prior to double contrast barium enema. The beer group scored slightly better (though not statistically significantly) both in the cleanliness and in the mucosal coating of the bowel than the control group with standard preparation. The fluid balance was unaltered. The patients in the beer group felt surprisingly well, likely due to the good fluid and energy balance provided by the beer. The beer preparation could be used in cases, when the patients are ready to intake beer and want to maintain a good nutritional status. (orig.) [de

  14. Bayesian inference from count data using discrete uniform priors.

    Directory of Open Access Journals (Sweden)

    Federico Comoglio

    Full Text Available We consider a set of sample counts obtained by sampling arbitrary fractions of a finite volume containing an homogeneously dispersed population of identical objects. We report a Bayesian derivation of the posterior probability distribution of the population size using a binomial likelihood and non-conjugate, discrete uniform priors under sampling with or without replacement. Our derivation yields a computationally feasible formula that can prove useful in a variety of statistical problems involving absolute quantification under uncertainty. We implemented our algorithm in the R package dupiR and compared it with a previously proposed Bayesian method based on a Gamma prior. As a showcase, we demonstrate that our inference framework can be used to estimate bacterial survival curves from measurements characterized by extremely low or zero counts and rather high sampling fractions. All in all, we provide a versatile, general purpose algorithm to infer population sizes from count data, which can find application in a broad spectrum of biological and physical problems.

  15. Testability evaluation using prior information of multiple sources

    Directory of Open Access Journals (Sweden)

    Wang Chao

    2014-08-01

    Full Text Available Testability plays an important role in improving the readiness and decreasing the life-cycle cost of equipment. Testability demonstration and evaluation is of significance in measuring such testability indexes as fault detection rate (FDR and fault isolation rate (FIR, which is useful to the producer in mastering the testability level and improving the testability design, and helpful to the consumer in making purchase decisions. Aiming at the problems with a small sample of testability demonstration test data (TDTD such as low evaluation confidence and inaccurate result, a testability evaluation method is proposed based on the prior information of multiple sources and Bayes theory. Firstly, the types of prior information are analyzed. The maximum entropy method is applied to the prior information with the mean and interval estimate forms on the testability index to obtain the parameters of prior probability density function (PDF, and the empirical Bayesian method is used to get the parameters for the prior information with a success-fail form. Then, a parametrical data consistency check method is used to check the compatibility between all the sources of prior information and TDTD. For the prior information to pass the check, the prior credibility is calculated. A mixed prior distribution is formed based on the prior PDFs and the corresponding credibility. The Bayesian posterior distribution model is acquired with the mixed prior distribution and TDTD, based on which the point and interval estimates are calculated. Finally, examples of a flying control system are used to verify the proposed method. The results show that the proposed method is feasible and effective.

  16. Characteristics of prepared gamma-ray calibration sources for radioactivity measurement of environmental and radiation control samples

    International Nuclear Information System (INIS)

    Samat, S.B.; Oi, Yoshihiro; Taki, Mitsumasa; Manabe, Iwao; Yoshida, Makoto; Minami, Kentaro

    1995-03-01

    Several types of calibration source having different density were prepared using one or combinations of those materials, namely foam cement, liquid, glass beads, polystyrene foam bead and hard plastic bead for gamma-ray spectrometry of the samples with different densities and shapes(variable height with constant base area). For each type of the source, a few sources were prepared to examine characteristics in such cases as (a) different heights but constant density, and (b) constant height and constant density. For the foam cement source, several sources with different densities and a constant height were prepared. All the sources were measured with a gamma-ray spectrometry system and the results were discussed. This report also presents the results obtained from the experiments for the evaluation of (1) the variation of detector efficiency-energy with gamma-ray energy, and (2) the variation of detector efficiency with density of the sources. (author)

  17. Practical aspects of the use of the X(2) holder for HRTEM-quality TEM sample preparation by FIB.

    Science.gov (United States)

    van Mierlo, Willem; Geiger, Dorin; Robins, Alan; Stumpf, Matthias; Ray, Mary Louise; Fischione, Paul; Kaiser, Ute

    2014-12-01

    The X(2) holder enables the effective production of thin, electron transparent samples for high-resolution transmission electron microscopy (HRTEM). Improvements to the X(2) holder for high-quality transmission electron microscopy (TEM) sample preparation are presented in this paper. We discuss the influence of backscattered electrons (BSE) from the sample holder in determining the lamella thickness in situ and demonstrate that a significant improvement in thickness determination can be achieved by comparatively simple means using the relative BSE intensity. We show (using Monte Carlo simulations) that by taking into account the finite collection angle of the electron backscatter detector, an approximately 20% underestimation of the lamella thickness in a silicon sample can be avoided. However, a correct thickness determination for light-element lamellas still remains a problem with the backscatter method; we introduce a more accurate method using the energy dispersive X-ray spectroscopy (EDX) signal for in situ thickness determination. Finally, we demonstrate how to produce a thin lamella with a nearly damage-free surface using the X(2) holder in combination with sub-kV polishing in the Fischione Instruments׳ NanoMill(®) TEM specimen preparation system. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Preparation of shaped bodies

    International Nuclear Information System (INIS)

    Sutcliffe, P.W.; Isaacs, J.W.; Lyon, C.E.

    1979-01-01

    A method for the preparation of a shaped body includes pressing a powder to give a 'green' shaped body, the powder having been made by comminuting a material prepared by means of a gelation process, the material prior to comminuting being of a selected physical configuration (e.g. spherical). Thus, a material prepared by means of a gelation process can be transported and handled in an environmentally desirable, substantially dust-free form (e.g. spherical particles) and then comminuted to produce a powder for pressing into e.g. a shaped nuclear fuel body (e.g. pellets of (70%U/30%Pu)O 2 ), which can be sintered. (author)

  19. ArF photo resist pattern sample preparation method using FIB without protective coating

    Science.gov (United States)

    Okushima, Hirohisa; Onozuka, Toshihiko; Kuroda, Yasushi; Yaguchi, Toshie; Umemura, Kaoru; Tamochi, Ryuichiro; Watanabe, Kenji; Hasegawa, Norio; Kawata, Isao; Rijpers, Bart

    2006-03-01

    This paper presents a novel method of FIB (FIB: focused ion beam) sample preparation to accurately evaluate critical dimensions and profiles of ArF photo resist patterns without the use of a protective coating on the photo resist. In order to accomplish this, the FIB micro-sampling method that is one of effective FIB milling and fabrication method was employed. First a Si cap is picked up from a silicon wafer and fixed to ArF photo resist patterns to protect against ion beam irradiation. Then, a micro-sample, a piece of Si-capped ArF photo resist, was extracted from the bulk ArF photo resist. In this procedure, this silicon cap always protects ArF photo resist patterns against ion beam irradiation. For the next step, the micro-sample is fixed to a needle stub of the FIB-STEM (STEM: scanning transmission electron microscopy) compatible rotation holder. This sample on the needle stub was rotated 180 degrees and milled from the side of Si substrate. Lastly, the sample is milled to the thickness of 2μm. In this process, the ion beam is irradiating from the silicon substrate side to minimize the ion beam irradiation damages on the ArF photo resist patterns. EDX (EDX: Energy dispersive X-ray spectroscopy) analysis proved that no gallium ions were detected on the surface of the ArF photo resist patterns. The feasibility of high accelerating voltage observation of STEM to observe line edge roughness of a thick sample like 2μm without shrinkage has been demonstrated.

  20. Optimized sample preparation for two-dimensional gel electrophoresis of soluble proteins from chicken bursa of Fabricius

    Directory of Open Access Journals (Sweden)

    Zheng Xiaojuan

    2009-10-01

    Full Text Available Abstract Background Two-dimensional gel electrophoresis (2-DE is a powerful method to study protein expression and function in living organisms and diseases. This technique, however, has not been applied to avian bursa of Fabricius (BF, a central immune organ. Here, optimized 2-DE sample preparation methodologies were constructed for the chicken BF tissue. Using the optimized protocol, we performed further 2-DE analysis on a soluble protein extract from the BF of chickens infected with virulent avibirnavirus. To demonstrate the quality of the extracted proteins, several differentially expressed protein spots selected were cut from 2-DE gels and identified by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS. Results An extraction buffer containing 7 M urea, 2 M thiourea, 2% (w/v 3-[(3-cholamidopropyl-dimethylammonio]-1-propanesulfonate (CHAPS, 50 mM dithiothreitol (DTT, 0.2% Bio-Lyte 3/10, 1 mM phenylmethylsulfonyl fluoride (PMSF, 20 U/ml Deoxyribonuclease I (DNase I, and 0.25 mg/ml Ribonuclease A (RNase A, combined with sonication and vortex, yielded the best 2-DE data. Relative to non-frozen immobilized pH gradient (IPG strips, frozen IPG strips did not result in significant changes in the 2-DE patterns after isoelectric focusing (IEF. When the optimized protocol was used to analyze the spleen and thymus, as well as avibirnavirus-infected bursa, high quality 2-DE protein expression profiles were obtained. 2-DE maps of BF of chickens infected with virulent avibirnavirus were visibly different and many differentially expressed proteins were found. Conclusion These results showed that method C, in concert extraction buffer IV, was the most favorable for preparing samples for IEF and subsequent protein separation and yielded the best quality 2-DE patterns. The optimized protocol is a useful sample preparation method for comparative proteomics analysis of chicken BF tissues.

  1. Evaluation of sample preparation methods and optimization of nickel determination in vegetable tissues

    Directory of Open Access Journals (Sweden)

    Rodrigo Fernando dos Santos Salazar

    2011-02-01

    Full Text Available Nickel, although essential to plants, may be toxic to plants and animals. It is mainly assimilated by food ingestion. However, information about the average levels of elements (including Ni in edible vegetables from different regions is still scarce in Brazil. The objectives of this study were to: (a evaluate and optimize a method for preparation of vegetable tissue samples for Ni determination; (b optimize the analytical procedures for determination by Flame Atomic Absorption Spectrometry (FAAS and by Electrothermal Atomic Absorption (ETAAS in vegetable samples and (c determine the Ni concentration in vegetables consumed in the cities of Lorena and Taubaté in the Vale do Paraíba, State of São Paulo, Brazil. By means of the analytical technique for determination by ETAAS or FAAS, the results were validated by the test of analyte addition and recovery. The most viable method tested for quantification of this element was HClO4-HNO3 wet digestion. All samples but carrot tissue collected in Lorena contained Ni levels above the permitted by the Brazilian Ministry of Health. The most disturbing results, requiring more detailed studies, were the Ni concentrations measured in carrot samples from Taubaté, where levels were five times higher than permitted by Brazilian regulations.

  2. The MEGAPIE PIE sample preparation

    International Nuclear Information System (INIS)

    Wohlmuther, M.; Boutellier, V.; Dai, Y.; Gavillet, D.; Geissmann, K.; Hahl, S.; Hammer, B.; Lagotzki, A.; Leu, H.; Linder, H.P.; Kalt, A.; Kuster, D.; Neuhausen, J.; Schumann, D.; Schwarz, R.; Schweikert, H.; Spahr, A.; Suter, P.; Teichmann, S.; Thomsen, K.; Wiese, H.; Wagner, W.; Zimmermann, U.; Zumbach, C.

    2015-01-01

    On the way towards Accelerator-driven Systems (ADS), the MEGAPIE (Mega-Watt Pilot Experiment) project is one of the key milestones. The MEGAPIE project aimed to prove that a liquid Lead-Bismuth-Eutectic (LBE) spallation target can be licensed, planned, built, operated, dismantled, examined and disposed. The project has finished the phase of producing the samples for Post-irradiation Examination (PIE). Samples to study structural material property changes due to the harsh environment of high temperatures, contact with flowing liquid metal (LBE), proton and neutron irradiation will be investigated by all partner laboratories (CEA, CNRS, ENEA, KIT, PSI and SCK-CEN). (authors)

  3. 21 CFR 510.440 - Injectable iron preparations.

    Science.gov (United States)

    2010-04-01

    ...) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS NEW ANIMAL DRUGS Requirements for Specific New Animal Drugs... preparations have been shown to be safe, such articles are regarded as new animal drugs within the meaning of... required prior to the marketing of such preparations within the jurisdiction of the act. In addition to the...

  4. Influence of sample preparation on the transformation of low-density to high-density amorphous ice: An explanation based on the potential energy landscape

    Science.gov (United States)

    Giovambattista, Nicolas; Starr, Francis W.; Poole, Peter H.

    2017-07-01

    Experiments and computer simulations of the transformations of amorphous ices display different behaviors depending on sample preparation methods and on the rates of change of temperature and pressure to which samples are subjected. In addition to these factors, simulation results also depend strongly on the chosen water model. Using computer simulations of the ST2 water model, we study how the sharpness of the compression-induced transition from low-density amorphous ice (LDA) to high-density amorphous ice (HDA) is influenced by the preparation of LDA. By studying LDA samples prepared using widely different procedures, we find that the sharpness of the LDA-to-HDA transformation is correlated with the depth of the initial LDA sample in the potential energy landscape (PEL), as characterized by the inherent structure energy. Our results show that the complex phenomenology of the amorphous ices reported in experiments and computer simulations can be understood and predicted in a unified way from knowledge of the PEL of the system.

  5. Reagentless mechanical cell lysis by nanoscale barbs in microchannels for sample preparation.

    Science.gov (United States)

    Di Carlo, Dino; Jeong, Ki-Hun; Lee, Luke P

    2003-11-01

    A highly effective, reagentless, mechanical cell lysis device integrated in microfluidic channels is reported. Sample preparation, specifically cell lysis, is a critical element in 'lab-on-chip' applications. However, traditional methods of cell lysis require purification steps or complicated fabrication steps that a simple mechanical method of lysis may avoid. A simple and effective mechanical cell lysis system is designed, microfabricated, and characterized to quantify the efficiency of cell lysis and biomolecule accessibility. The device functionality is based on a microfluidic filter region with nanostructured barbs created using a modified deep reactive ion etching process. Mechanical lysis is characterized by using a membrane impermeable dye. Three main mechanisms of micro-mechanical lysis are described. Quantitative measurements of accessible protein as compared to a chemically lysed sample are acquired with optical absorption measurements at 280 and 414 nm. At a flow rate of 300 microL min(-1) within the filter region total protein and hemoglobin accessibilities of 4.8% and 7.5% are observed respectively as compared to 1.9% and 3.2% for a filter without nanostructured barbs.

  6. Sample preparation for phosphoproteomic analysis of circadian time series in Arabidopsis thaliana.

    Science.gov (United States)

    Krahmer, Johanna; Hindle, Matthew M; Martin, Sarah F; Le Bihan, Thierry; Millar, Andrew J

    2015-01-01

    Systems biological approaches to study the Arabidopsis thaliana circadian clock have mainly focused on transcriptomics while little is known about the proteome, and even less about posttranslational modifications. Evidence has emerged that posttranslational protein modifications, in particular phosphorylation, play an important role for the clock and its output. Phosphoproteomics is the method of choice for a large-scale approach to gain more knowledge about rhythmic protein phosphorylation. Recent plant phosphoproteomics publications have identified several thousand phosphopeptides. However, the methods used in these studies are very labor-intensive and therefore not suitable to apply to a well-replicated circadian time series. To address this issue, we present and compare different strategies for sample preparation for phosphoproteomics that are compatible with large numbers of samples. Methods are compared regarding number of identifications, variability of quantitation, and functional categorization. We focus on the type of detergent used for protein extraction as well as methods for its removal. We also test a simple two-fraction separation of the protein extract. © 2015 Elsevier Inc. All rights reserved.

  7. Parameter estimation of multivariate multiple regression model using bayesian with non-informative Jeffreys’ prior distribution

    Science.gov (United States)

    Saputro, D. R. S.; Amalia, F.; Widyaningsih, P.; Affan, R. C.

    2018-05-01

    Bayesian method is a method that can be used to estimate the parameters of multivariate multiple regression model. Bayesian method has two distributions, there are prior and posterior distributions. Posterior distribution is influenced by the selection of prior distribution. Jeffreys’ prior distribution is a kind of Non-informative prior distribution. This prior is used when the information about parameter not available. Non-informative Jeffreys’ prior distribution is combined with the sample information resulting the posterior distribution. Posterior distribution is used to estimate the parameter. The purposes of this research is to estimate the parameters of multivariate regression model using Bayesian method with Non-informative Jeffreys’ prior distribution. Based on the results and discussion, parameter estimation of β and Σ which were obtained from expected value of random variable of marginal posterior distribution function. The marginal posterior distributions for β and Σ are multivariate normal and inverse Wishart. However, in calculation of the expected value involving integral of a function which difficult to determine the value. Therefore, approach is needed by generating of random samples according to the posterior distribution characteristics of each parameter using Markov chain Monte Carlo (MCMC) Gibbs sampling algorithm.

  8. Cytological preparations for molecular analysis: A review of technical procedures, advantages and limitations for referring samples for testing.

    Science.gov (United States)

    da Cunha Santos, G; Saieg, M A; Troncone, G; Zeppa, P

    2018-04-01

    Minimally invasive procedures such as endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) must yield not only good quality and quantity of material for morphological assessment, but also an adequate sample for analysis of molecular markers to guide patients to appropriate targeted therapies. In this context, cytopathologists worldwide should be familiar with minimum requirements for refereeing cytological samples for testing. The present manuscript is a review with comprehensive description of the content of the workshop entitled Cytological preparations for molecular analysis: pre-analytical issues for EBUS TBNA, presented at the 40th European Congress of Cytopathology in Liverpool, UK. The present review emphasises the advantages and limitations of different types of cytology substrates used for molecular analysis such as archival smears, liquid-based preparations, archival cytospin preparations and FTA (Flinders Technology Associates) cards, as well as their technical requirements/features. These various types of cytological specimens can be successfully used for an extensive array of molecular studies, but the quality and quantity of extracted nucleic acids rely directly on adequate pre-analytical assessment of those samples. In this setting, cytopathologists must not only be familiar with the different types of specimens and associated technical procedures, but also correctly handle the material provided by minimally invasive procedures, ensuring that there is sufficient amount of material for a precise diagnosis and correct management of the patient through personalised care. © 2018 John Wiley & Sons Ltd.

  9. Use of the electrodeposition technique in the preparation of samples of 237Np and its determination by alpha spectrometry

    International Nuclear Information System (INIS)

    Mertzig, W.; Matsuda, H.T.; Araujo, B.F. de; Araujo, J.A. de.

    1981-05-01

    The electroplating technique to prepare 237 Np source and its determination by alpha spectrometry is presented. The samples were prepared using a lucite-eletrolitic cell manufactured at IPEN, specially to trace amounts of actinides. A polished brass disk coated with Ni film has been used as cathodo and a fixed Pt wire as anode. The electroplated samples were alpha counted using a surface barrier detector. The optimum conditions to obtain the quantitative deposition of 237 Np have been achieved by studying the effects of some parameters as current density, pH and concentration of eletrolitic solution and time of eletrodeposition, using a carrier technique. After preliminary purification, the method is applied to control trace amounts of 237 Np in the Purex process solutions. (Author) [pt

  10. Sample preparation and biomass determination of SRF model mixture using cryogenic milling and the adapted balance method

    Energy Technology Data Exchange (ETDEWEB)

    Schnöller, Johannes, E-mail: johannes.schnoeller@chello.at; Aschenbrenner, Philipp; Hahn, Manuel; Fellner, Johann; Rechberger, Helmut

    2014-11-15

    Highlights: • An alternative sample comminution procedure for SRF is tested. • Proof of principle is shown on a SRF model mixture. • The biogenic content of the SRF is analyzed with the adapted balance method. • The novel method combines combustion analysis and a data reconciliation algorithm. • Factors for the variance of the analysis results are statistically quantified. - Abstract: The biogenic fraction of a simple solid recovered fuel (SRF) mixture (80 wt% printer paper/20 wt% high density polyethylene) is analyzed with the in-house developed adapted balance method (aBM). This fairly new approach is a combination of combustion elemental analysis (CHNS) and a data reconciliation algorithm based on successive linearisation for evaluation of the analysis results. This method shows a great potential as an alternative way to determine the biomass content in SRF. However, the employed analytical technique (CHNS elemental analysis) restricts the probed sample mass to low amounts in the range of a few hundred milligrams. This requires sample comminution to small grain sizes (<200 μm) to generate representative SRF specimen. This is not easily accomplished for certain material mixtures (e.g. SRF with rubber content) by conventional means of sample size reduction. This paper presents a proof of principle investigation of the sample preparation and analysis of an SRF model mixture with the use of cryogenic impact milling (final sample comminution) and the adapted balance method (determination of biomass content). The so derived sample preparation methodology (cutting mills and cryogenic impact milling) shows a better performance in accuracy and precision for the determination of the biomass content than one solely based on cutting mills. The results for the determination of the biogenic fraction are within 1–5% of the data obtained by the reference methods, selective dissolution method (SDM) and {sup 14}C-method ({sup 14}C-M)

  11. 40 CFR 141.703 - Sampling locations.

    Science.gov (United States)

    2010-07-01

    ... samples prior to the point of filter backwash water addition. (d) Bank filtration. (1) Systems that... applicable, must collect source water samples in the surface water prior to bank filtration. (2) Systems that use bank filtration as pretreatment to a filtration plant must collect source water samples from the...

  12. Lights Will Guide You : Sample Preparation and Applications for Integrated Laser and Electron Microscopy

    Science.gov (United States)

    Karreman, M. A.

    2013-03-01

    Correlative microscopy is the combined use of two different forms of microscopy in the study of a specimen, allowing for the exploitation of the advantages of both imaging tools. The integrated Laser and Electron Microscope (iLEM), developed at Utrecht University, combines a fluorescence microscope (FM) and a transmission electron microscope (TEM) in a single set-up. The region of interest in the specimen is labeled or tagged with a fluorescent probe and can easily be identified within a large field of view with the FM. Next, this same area is retraced in the TEM and can be studied at high resolution. The iLEM demands samples that can be imaged with both FM and TEM. Biological specimen, typically composed of light elements, generate low image contrast in the TEM. Therefore, these samples are often ‘contrasted’ with heavy metal stains. FM, on the other hand, images fluorescent samples. Sample preparation for correlative microscopy, and iLEM in particular, is complicated by the fact that the heavy metals stains employed for TEM quench the fluorescent signal of the probe that is imaged with FM. The first part of this thesis outlines preparation procedures for biological material yielding specimen that can be imaged with the iLEM. Here, approaches for the contrasting of thin sections of cells and tissue are introduced that do not affect the fluorescence signal of the probe that marks the region of interest. Furthermore, two novel procedures, VIS2FIXH and VIS2FIX­FS are described that allow for the chemical fixation of thin sections of cryo-immobilized material. These procedures greatly expedite the sample preparation process, and open up novel possibilities for the immuno-labeling of difficult antigens, eg. proteins and lipids that are challenging to preserve. The second part of this thesis describes applications of iLEM in research in the field of life and material science. The iLEM was employed in the study of UVC induced apoptosis (programmed cell death) of

  13. Initial Study on Thin Film Preparation of Carbon Nanodots Composites as Luminescence Material

    Science.gov (United States)

    Iskandar, F.; Aimon, A. H.; Akmaluddin, A. R.; Nuryadin, B. W.; Abdullah, M.

    2016-08-01

    Nowadays, the developments of phosphors materials require elements without noble metals and simple production process. Carbon nanodots (C-dots) are one of phosphor materials with wide range of emission band, and high biocompatibility. In this research thin film carbon nanodots composite have been prepared by spin coating method. Prior deposition, powder carbon nanodots were synthesized from a mixture of commercial urea as the nitrogen sources and citric acid as a carbon source by using hydrothermal and microwave-assisted heating method. The prepared powder was dispersed in transparent epoxy resin and then coated on glass substrate. The photoluminescence result for sample with 0.035 g citric acid exhibited an intense, single, homogeneous and broad spectrum with yellowish emission upon excitation at 365 nm. The Fourier Transform Infrared Spectroscopy (FTIR) result showed the existences of C=C, C-H, C=O, N-H and O-H functional groups which confirmed the quality of the sample. Further, based on UV-Vis measurement, the prepared thin film was highly transparent (transmittance 90%) with estimated film thickness around 764 nm. This result may open an opportunity for optoelectronic devices.

  14. Initial Study on Thin Film Preparation of Carbon Nanodots Composites as Luminescence Material

    International Nuclear Information System (INIS)

    Iskandar, F; Aimon, A H; Akmaluddin, A R; Abdullah, M; Nuryadin, B W

    2016-01-01

    Nowadays, the developments of phosphors materials require elements without noble metals and simple production process. Carbon nanodots (C-dots) are one of phosphor materials with wide range of emission band, and high biocompatibility. In this research thin film carbon nanodots composite have been prepared by spin coating method. Prior deposition, powder carbon nanodots were synthesized from a mixture of commercial urea as the nitrogen sources and citric acid as a carbon source by using hydrothermal and microwave-assisted heating method. The prepared powder was dispersed in transparent epoxy resin and then coated on glass substrate. The photoluminescence result for sample with 0.035 g citric acid exhibited an intense, single, homogeneous and broad spectrum with yellowish emission upon excitation at 365 nm. The Fourier Transform Infrared Spectroscopy (FTIR) result showed the existences of C=C, C-H, C=O, N-H and O-H functional groups which confirmed the quality of the sample. Further, based on UV-Vis measurement, the prepared thin film was highly transparent (transmittance 90%) with estimated film thickness around 764 nm. This result may open an opportunity for optoelectronic devices. (paper)

  15. Study on the preparation and stability of uranium carbide samples for the determination of oxygen, hydrogen and nitrogen by fusion under high vacuum

    International Nuclear Information System (INIS)

    Perez Garcia, M.

    1966-01-01

    In view of the high reactivity of uranium carbide, the method employed for the preparation of the sample for the analysis of its gas content: oxygen, hydrogen and nitrogen, has a decisive influence on the analytical results. The variation in the O 2 , H 2 and N 2 content of the uranium carbide has been studied in this paper with the methods utilized for the sample preparation (grinding and cutting). (Author) 9 refs

  16. Study of sample preparation for quantitative analysis of amino acids in human sweat by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Delgado-Povedano, M M; Calderón-Santiago, M; Priego-Capote, F; Luque de Castro, M D

    2016-01-01

    The determination of physiological levels of amino acids is important to aid in the diagnosis and treatment of several diseases and nutritional status of individuals. Amino acids are frequently determined in biofluids such as blood (serum or plasma) and urine; however, there are less common biofluids with different concentration profiles of amino acids that could be of interest. One of these biofluids is sweat that can be obtained in a non-invasive manner and is characterized by low complex composition. The analysis of amino acids in human sweat requires the development of sample preparation strategies according to the sample matrix and small collected volume. The influence of sample preparation on the quantitative analysis of amino acids in sweat by LC-MS/MS has been assessed through a comparison between two strategies: dilution of sweat and centrifugal microsolid-phase extraction (c-μSPE). In both cases, several dilution factors were assayed for in-depth knowledge of the matrix effects, and the use of c-μSPE provided the best results in terms of accuracy. The behavior of the target analytes was a function of the dilution factor, thus providing a pattern for sample preparation that depended on the amino acid to be determined. The concentration of amino acids in sweat ranges between 6.20 ng mL(-1) (for homocysteine) and 259.77 µg mL(-1) (for serine) with precision, expressed as relative standard deviation, within 1.1-21.4%. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Application of Bayesian Decision Theory Based on Prior Information in the Multi-Objective Optimization Problem

    Directory of Open Access Journals (Sweden)

    Xia Lei

    2010-12-01

    Full Text Available General multi-objective optimization methods are hard to obtain prior information, how to utilize prior information has been a challenge. This paper analyzes the characteristics of Bayesian decision-making based on maximum entropy principle and prior information, especially in case that how to effectively improve decision-making reliability in deficiency of reference samples. The paper exhibits effectiveness of the proposed method using the real application of multi-frequency offset estimation in distributed multiple-input multiple-output system. The simulation results demonstrate Bayesian decision-making based on prior information has better global searching capability when sampling data is deficient.

  18. Assessment of different sample preparation routes for mass spectrometric monitoring and imaging of lipids in bone cells via ToF-SIMS

    Science.gov (United States)

    Schaepe, Kaija; Kokesch-Himmelreich, Julia; Rohnke, Marcus; Wagner, Alena-Svenja; Schaaf, Thimo; Wenisch, Sabine; Janek, Jürgen

    2015-01-01

    In ToF-SIMS analysis, the experimental outcome from cell experiments is to a great extent influenced by the sample preparation routine. In order to better judge this critical influence in the case of lipid analysis, a detailed comparison of different sample preparation routines is performed—aiming at an optimized preparation routine for systematic lipid imaging of cell cultures. For this purpose, human mesenchymal stem cells were analyzed: (a) as chemically fixed, (b) freeze-dried, and (c) frozen-hydrated. For chemical fixation, different fixatives, i.e., glutaraldehyde, paraformaldehyde, and a mixture of both, were tested with different postfixative handling procedures like storage in phosphate buffered saline, water or critical point drying. Furthermore, secondary lipid fixation via osmium tetroxide was taken into account and the effect of an ascending alcohol series with and without this secondary lipid fixation was evaluated. Concerning freeze-drying, three different postprocessing possibilities were examined. One can be considered as a pure cryofixation technique while the other two routes were based on chemical fixation. Cryofixation methods known from literature, i.e., freeze-fracturing and simple frozen-hydrated preparation, were also evaluated to complete the comparison of sample preparation techniques. Subsequent data evaluation of SIMS spectra in both, positive and negative, ion mode was performed via principal component analysis by use of peak sets representative for lipids. For freeze-fracturing, these experiments revealed poor reproducibility making this preparation route unsuitable for systematic investigations and statistic data evaluation. Freeze-drying after cryofixation showed improved reproducibility and well preserved lipid contents while the other freeze-drying procedures showed drawbacks in one of these criteria. In comparison, chemical fixation techniques via glutar- and/or paraformaldehyde proved most suitable in terms of reproducibility

  19. KOH catalysed preparation of activated carbon aerogels for dye adsorption.

    Science.gov (United States)

    Ling, Sie King; Tian, H Y; Wang, Shaobin; Rufford, Thomas; Zhu, Z H; Buckley, C E

    2011-05-01

    Organic carbon aerogels (CAs) were prepared by a sol-gel method from polymerisation of resorcinol, furfural, and hexamethylenetetramine catalysed by KOH at around pH 9 using ambient pressure drying. The effect of KOH in the sol-gel on CA synthesis was studied. It was found that addition of KOH prior to the sol-gel polymerisation process improved thermal stability of the gel, prevented the crystallinity of the gel to graphite, increased the microporosity of CA and promoted activation of CA. The CAs prepared using the KOH catalyst exhibited higher porosity than uncatalysed prepared samples. Activation in CO(2) at higher temperature also enhanced the porosity of CAs. Adsorption tests indicated that the CAs were effective for both basic and acid dye adsorption and the adsorption increased with increasing surface area and pore volume. The kinetic adsorption of dyes was diffusion control and could be described by the second-order kinetic model. The equilibrium adsorption of dyes was higher than activated carbon. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. A novel method for sample preparation of fresh lung cancer tissue for proteomics analysis by tumor cell enrichment and removal of blood contaminants

    Directory of Open Access Journals (Sweden)

    Orre Lotta

    2010-02-01

    Full Text Available Abstract Background In-depth proteomics analyses of tumors are frequently biased by the presence of blood components and stromal contamination, which leads to large experimental variation and decreases the proteome coverage. We have established a reproducible method to prepare freshly collected lung tumors for proteomics analysis, aiming at tumor cell enrichment and reduction of plasma protein contamination. We obtained enriched tumor-cell suspensions (ETS from six lung cancer cases (two adenocarcinomas, two squamous-cell carcinomas, two large-cell carcinomas and from two normal lung samples. The cell content of resulting ETS was evaluated with immunocytological stainings and compared with the histologic pattern of the original specimens. By means of a quantitative mass spectrometry-based method we evaluated the reproducibility of the sample preparation protocol and we assessed the proteome coverage by comparing lysates from ETS samples with the direct lysate of corresponding fresh-frozen samples. Results Cytological analyses on cytospin specimens showed that the percentage of tumoral cells in the ETS samples ranged from 20% to 70%. In the normal lung samples the percentage of epithelial cells was less then 10%. The reproducibility of the sample preparation protocol was very good, with coefficient of variation at the peptide level and at the protein level of 13% and 7%, respectively. Proteomics analysis led to the identification of a significantly higher number of proteins in the ETS samples than in the FF samples (244 vs 109, respectively. Albumin and hemoglobin were among the top 5 most abundant proteins identified in the FF samples, showing a high contamination with blood and plasma proteins, whereas ubiquitin and the mitochondrial ATP synthase 5A1 where among the top 5 most abundant proteins in the ETS samples. Conclusion The method is feasible and reproducible. We could obtain a fair enrichment of cells but the major benefit of the method