WorldWideScience

Sample records for sample derivatization mass

  1. Membrane Assisted Simultaneous Extraction and Derivatization with Triphenylphosphine of Elemental Sulfur in Arabian Crude Samples by Gas Chromatography/Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Ibrahim Al-Zahrani

    2015-01-01

    Full Text Available Determination of trace level elemental sulfur from crude oil samples is a tedious task. Recently, several gas chromatographic methods were reported in which selective triphenylphosphine derivatization of sulfur was used to form triphenylphosphine sulfide. Direct quantitation of elemental sulfur from crude oil requires an efficient sample preparation method. This paper describes how simultaneous extraction derivatization of elemental sulfur was performed for the first time using porous hollow fiber membrane. A thick (0.25 um pore size; 1550 μm wall thickness; and 5500 μm inner diameter hollow fiber membrane filled with triphenylphosphine (dissolved N-methylpyrrolidone is used as a solvent bar. The solvent bar is tumbled freely in the crude oil sample; the elemental sulfur was extracted and derivatized. Finally, the derivatized sulfur was analyzed by gas chromatography/mass spectrometry. Various experimental conditions of solvent bar microextraction (SBME were optimized to achieve higher extraction. The linear range was established between 1 and 50 μg/mL, while a squared regression coefficient was found to be 0.9959 μg/mL. Relative standard deviation (RSD was below 10%. Relative recoveries were calculated for SBME in crude oil samples and were in the range between 98.2% and 101.2%.

  2. One-step derivatization and preconcentration microextraction technique for determination of bisphenol A in beverage samples by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Fontana, Ariel R; Muñoz de Toro, Mónica; Altamirano, Jorgelina C

    2011-04-27

    A simple technique based on ultrasound-assisted emulsification microextraction in situ derivatization (USAEME-ISD) is proposed for the one-step derivatization, extraction, and preconcentration of bisphenol A (BPA) in beverage samples prior to gas chromatography-mass spectrometry (GC-MS) analysis. BPA was in situ derivatized with acetic anhydride and simultaneously extracted and preconcentrated by using USAEME. Variables affecting the extraction efficiency of BPA were evaluated. Under optimal experimental conditions, the detection limit (LOD) was 38 ng L(-1) with a relative standard deviation (RSD) value of 11.6%. The linear working range was 100-1250 ng L(-1), and the coefficient of estimation (r(2)) of the calibration curve was ≥0.9971. The robustness of the proposed methodology was probed by developing a recovery study at two concentrations (125 and 500 ng L(-1)) over different beverage samples. This study led to a satisfactory result achieving recoveries of ≥82%, which showed acceptable robustness for determination of nanograms per liter of BPA in samples of food safety interest.

  3. Review of in situ derivatization techniques for enhanced bioanalysis using liquid chromatography with mass spectrometry.

    Science.gov (United States)

    Baghdady, Yehia Z; Schug, Kevin A

    2016-01-01

    Accurate and specific analysis of target molecules in complex biological matrices remains a significant challenge, especially when ultra-trace detection limits are required. Liquid chromatography with mass spectrometry is often the method of choice for bioanalysis. Conventional sample preparation and clean-up methods prior to the analysis of biological fluids such as liquid-liquid extraction, solid-phase extraction, or protein precipitation are time-consuming, tedious, and can negatively affect target recovery and detection sensitivity. An alternative or complementary strategy is the use of an off-line or on-line in situ derivatization technique. In situ derivatization can be incorporated to directly derivatize target analytes in their native biological matrices, without any prior sample clean-up methods, to substitute or even enhance the extraction and preconcentration efficiency of these traditional sample preparation methods. Designed appropriately, it can reduce the number of sample preparation steps necessary prior to analysis. Moreover, in situ derivatization can be used to enhance the performance of the developed liquid chromatography with mass spectrometry-based bioanalysis methods regarding stability, chromatographic separation, selectivity, and ionization efficiency. This review presents an overview of the commonly used in situ derivatization techniques coupled to liquid chromatography with mass spectrometry-based bioanalysis to guide and to stimulate future research. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Derivatization reagents in liquid chromatography/electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Santa, Tomofumi

    2011-01-01

    Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds. 2010 John Wiley & Sons, Ltd.

  5. Simultaneous identification and quantification of bisphenol A and 12 bisphenol analogues in environmental samples using precolumn derivatization and ultra high performance liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Wang, Zhonghe; Yu, Jing; Yao, Jiaxi; Wu, Linlin; Xiao, Hang; Wang, Jun; Gao, Rong

    2018-02-10

    A method for the identification and quantification of bisphenol A and 12 bisphenol analogues in river water and sediment samples combining liquid-liquid extraction, precolumn derivatization, and ultra high-performance liquid chromatography coupled with tandem mass spectrometry was developed and validated. Analytes were extracted from the river water sample using a liquid-liquid extraction method. Dansyl chloride was selected as a derivatization reagent. Derivatization reaction conditions affecting production of the dansyl derivatives were tested and optimized. All the derivatized target compounds were well separated and eluted in 10 min. Dansyl chloride labeled compounds were analyzed using a high-resolution mass spectrometer with electrospray ionization in the positive mode, and the results were confirmed and quantified in the parallel reaction monitoring mode. The method validation results showed a satisfactory level of sensitivity. Linearity was assessed using matrix-matched standard calibration, and good correlation coefficients were obtained. The limits of quantification for the analytes ranged from 0.005 to 0.02 ng/mL in river water and from 0.15 to 0.80 ng/g in sediment. Good reproducibility of the method in terms of intra- and interday precision was achieved, yielding relative standard deviations of less than 10.1 and 11.6%, respectively. Finally, this method was successfully applied to the analysis of real samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Analysis of Organic Molecules Extracted from Mars Analogues and Influence of Their Mineralogy Using N-Methyl-N-(tert-butyldimethylsilyl)Trifluoroacetamide Derivatization Coupled with Gas Chromatography Mass Spectrometry in Preparation for the Sample Analysis at Mars Derivatization Experiment on the Mars Science Laboratory Mission

    Science.gov (United States)

    Stalport, F.; Glavin, D. P.; Eigenbrode, J. L.; Bish, D.; Blake, D.; Coll, P.; Szopa, C.; Buch, A.; McAdam, A.; Dworkin, J. P.; hide

    2012-01-01

    The search for complex organic molecules on Mars, including important biomolecules such as amino acids and carboxylic acids will require a chemical extraction and derivatization step to transform these organic compounds into species that are sufficiently volatile to be detected by gas chromatography mass spectrometry (GCMS). We have developed, a one-pot extraction and chemical derivatization protocol using N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA) and dimethylformamide (DMF) for the Sample Analysis at Mars (SAM) experiment on the Mars Science Laboratory (MSL). The temperature and duration the derivatization reaction, pre-concentration of chemical derivatives, and gas chromatographic separation parameters have been optimized under SAM instrument design constraints. MTBSTFA/DMF extraction and derivatization at 300 C for several minutes of a variety of terrestrial Mars analogue materials facilitated the detection of amino acids and carboxylic acids in a surface soil sample collected from the Atacama Desert and a carbonate-rich stromatolite sample from Svalbard. However, the rapid reaction of MTBSTFA with water in several analogue materials that contained high abundances of hydrated minerals and the possible deactivation of derivatized compounds by iron oxides, as detected by XRD/XRF using the CheMin field unit Terra, proved to be highly problematic for the direct extraction of organics using MTBSTFA, The combination of pyrolysis and two different chemical derivatization methods employed by SAM should enable a wide range of organic compounds to be detected by GCMS if present on Mars,

  7. Phosphopeptide derivatization signatures to identify serine and threonine phosphorylated peptides by mass spectrometry.

    Science.gov (United States)

    Molloy, M P; Andrews, P C

    2001-11-15

    The development of rapid, global methods for monitoring states of protein phosphorylation would provide greater insight for understanding many fundamental biological processes. Current best practices use mass spectrometry (MS) to profile digests of purified proteins for evidence of phosphorylation. However, this approach is beset by inherent difficulties in both identifying phosphopeptides from within a complex mixture containing many other unmodified peptides and ionizing phosphopeptides in positive-ion MS. We have modified an approach that uses barium hydroxide to rapidly eliminate the phosphoryl group of serine and threonine modified amino acids, creating dehydroamino acids that are susceptible to nucleophilic derivatization. By derivatizing a protein digest with a mixture of two different alkanethiols, phosphopeptide-specific derivatives were readily distinguished by MS due to their characteristic ion-pair signature. The resulting tagged ion pairs accommodate simple and rapid screening for phosphopeptides in a protein digest, obviating the use of isotopically labeled samples for qualitative phosphopeptide detection. MALDI-MS is used in a first pass manner to detect derivatized phosphopeptides, while the remaining sample is available for tandem MS to reveal the site of derivatization and, thus, phosphorylation. We demonstrated the technique by identifying phosphopeptides from beta-casein and ovalbumin. The approach was further used to examine in vitro phosphorylation of recombinant human HSP22 by protein kinase C, revealing phosphorylation of Thr-63.

  8. A Derivatization and Validation Strategy for Determining the Spatial Localization of Endogenous Amine Metabolites in Tissues using MALDI Imaging Mass Spectrometry

    Science.gov (United States)

    Manier, M. Lisa; Spraggins, Jeffrey M.; Reyzer, Michelle L.; Norris, Jeremy L.; Caprioli, Richard M.

    2014-01-01

    Imaging mass spectrometry (IMS) studies increasingly focus on endogenous small molecular weight metabolites and consequently bring special analytical challenges. Since analytical tissue blanks do not exist for endogenous metabolites, careful consideration must be given to confirm molecular identity. Here we present approaches for the improvement in detection of endogenous amine metabolites such as amino acids and neurotransmitters in tissues through chemical derivatization and matrix-assisted laser desorption/ionization (MALDI) IMS. Chemical derivatization with 4-hydroxy-3-methoxycinnamaldehyde (CA) was used to improve sensitivity and specificity. CA was applied to the tissue via MALDI sample targets precoated with a mixture of derivatization reagent and ferulic acid (FA) as a MALDI matrix. Spatial distributions of chemically derivatized endogenous metabolites in tissue were determined by high-mass resolution and MSn imaging mass spectrometry. We highlight an analytical strategy for metabolite validation whereby tissue extracts are analyzed by high-performance liquid chromatography (HPLC)-MS/MS to unambiguously identify metabolites and distinguish them from isobaric compounds. PMID:25044893

  9. Derivatization of Dextran for Multiply Charged Ion Formation and Electrospray Ionization Time-of-Flight Mass Spectrometric Analysis

    Science.gov (United States)

    Tapia, Jesus B.; Hibbard, Hailey A. J.; Reynolds, Melissa M.

    2017-10-01

    We present the use of a simple, one-pot derivatization to allow the polysaccharide dextran to carry multiple positive charges, shifting its molecular weight distribution to a lower m/ z range. We performed this derivatization because molecular weight measurements of polysaccharides by mass spectrometry are challenging because of their lack of readily ionizable groups. The absence of ionizable groups limits proton abstraction and suppresses proton adduction during the ionization process, producing mass spectra with predominantly singly charged metal adduct ions, thereby limiting the detection of large polysaccharides. To address this challenge, we derivatized dextran T1 (approximately 1 kDa) by attaching ethylenediamine, giving dextran readily ionizable, terminal amine functional groups. The attached ethylenediamine groups facilitated proton adduction during the ionization process in positive ion mode. Using the low molecular weight dextran T1, we tracked the number of ethylenediamine attachments by measuring the mass shift from underivatized to derivatized dextran T1. Using electrospray ionization time-of-flight mass spectrometry, we observed derivatized dextran chains ranging from two to nine glucose residues with between one and four attachments/charges. Our success in shifting derivatized dextran T1 toward the low m/ z range suggests potential for this derivatization as a viable route for analysis of high molecular weight polysaccharides using electrospray ionization time-of-flight mass spectrometry. [Figure not available: see fulltext.

  10. Hollow-fiber-supported liquid phase microextraction with in situ derivatization and gas chromatography-mass spectrometry for determination of chlorophenols in human urine samples.

    Science.gov (United States)

    Ito, Rie; Kawaguchi, Migaku; Honda, Hidehiro; Koganei, Youji; Okanouchi, Noriya; Sakui, Norihiro; Saito, Koichi; Nakazawa, Hiroyuki

    2008-09-01

    A simple and highly sensitive method that involves hollow-fiber-supported liquid phase microextraction (HF-LPME) with in situ derivatization and gas chromatography-mass spectrometry (GC-MS) was developed for the determination of chlorophenols (CPs) such as 2,4-dichlorophenol (DCP), 2,4,6-trichlorophenol (TrCP), 2,3,4,6-tetrachlorophenol (TeCP) and pentachlorophenol (PCP) in human urine samples. Human urine samples were enzymatically de-conjugated with beta-glucuronidase and sulfatase. After de-conjugation, HF-LPME with in situ derivatization was performed. After extraction, 2 microl of extract was carefully withdrawn into a syringe and injected into the GC-MS system. The limits of detection (S/N=3) and quantification (S/N>10) of CPs in the human urine samples are 0.1-0.2 ng ml(-1) and 0.5-1 ng ml(-1), respectively. The calibration curve for CPs is linear with a correlation coefficient of >0.99 in the range of 0.5-500 ng ml(-1) for DCP and TrCP, and of 1-500 ng ml(-1) for TeCP and PCP, respectively. The average recoveries of CPs (n=6) in human urine samples are 81.0-104.0% (R.S.D.: 1.9-6.6%) with correction using added surrogate standards. When the proposed method was applied to human urine samples, CPs were detected at sub-ng ml(-1) level.

  11. Exposure Assessment of Acetamide in Milk, Beef, and Coffee Using Xanthydrol Derivatization and Gas Chromatography/Mass Spectrometry.

    Science.gov (United States)

    Vismeh, Ramin; Haddad, Diane; Moore, Janette; Nielson, Chandra; Bals, Bryan; Campbell, Tim; Julian, Allen; Teymouri, Farzaneh; Jones, A Daniel; Bringi, Venkataraman

    2018-01-10

    Acetamide has been classified as a possible human carcinogen, but uncertainties exist about its levels in foods. This report presents evidence that thermal decomposition of N-acetylated sugars and amino acids in heated gas chromatograph injectors contributes to artifactual acetamide in milk and beef. An alternative gas chromatography/mass spectrometry protocol based on derivatization of acetamide with 9-xanthydrol was optimized and shown to be free of artifactual acetamide formation. The protocol was validated using a surrogate analyte approach based on d 3 -acetamide and applied to analyze 23 pasteurized whole milk, 44 raw sirloin beef, and raw milk samples from 14 different cows, and yielded levels about 10-fold lower than those obtained by direct injection without derivatization. The xanthydrol derivatization procedure detected acetamide in every food sample tested at 390 ± 60 ppb in milk, 400 ± 80 ppb in beef, and 39 000 ± 9000 ppb in roasted coffee beans.

  12. Amino acid analysis in physiological samples by GC-MS with propyl chloroformate derivatization and iTRAQ-LC-MS/MS.

    Science.gov (United States)

    Dettmer, Katja; Stevens, Axel P; Fagerer, Stephan R; Kaspar, Hannelore; Oefner, Peter J

    2012-01-01

    Two mass spectrometry-based methods for the quantitative analysis of free amino acids are described. The first method uses propyl chloroformate/propanol derivatization and gas chromatography-quadrupole mass spectrometry (GC-qMS) analysis in single-ion monitoring mode. Derivatization is carried out directly in aqueous samples, thereby allowing automation of the entire procedure, including addition of reagents, extraction, and injection into the GC-MS. The method delivers the quantification of 26 amino acids. The isobaric tagging for relative and absolute quantification (iTRAQ) method employs the labeling of amino acids with isobaric iTRAQ tags. The tags contain two different cleavable reporter ions, one for the sample and one for the standard, which are detected by fragmentation in a tandem mass spectrometer. Reversed-phase liquid chromatography of the labeled amino acids is performed prior to mass spectrometric analysis to separate isobaric amino acids. The commercial iTRAQ kit allows for the analysis of 42 physiological amino acids with a respective isotope-labeled standard for each of these 42 amino acids.

  13. Analysis of radioactive mixed hazardous waste using derivatization gas chromatography/mass spectrometry, liquid chromatography, and liquid chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Campbell, J.A.; Lerner, B.D.; Bean, R.M.; Grant, K.E.; Lucke, R.B.; Mong, G.M.; Clauss, S.A.

    1994-08-01

    Six samples of core segments from Tank 101-SY were analyzed for chelators, chelator fragments, and several carboxylic acids by derivatization gas chromatography/mass spectrometry. The major components detected were ethylenediaminetetraacetic acid, nitroso-iminodiacetic acid, nitrilotriacetic acid, citric acid, succinic acid, and ethylenediaminetriacetic acid. The chelator of highest concentration was ethylenediaminetetraacetic acid in all six samples analyzed. Liquid chromatography was used to quantitate low molecular weight acids including oxalic, formic, glycolic, and acetic acids, which are present in the waste as acid salts. From 23 to 61% of the total organic carbon in the samples analyzed was accounted for by these acids

  14. Automated Online Solid-Phase Derivatization for Sensitive Quantification of Endogenous S-Nitrosoglutathione and Rapid Capture of Other Low-Molecular-Mass S-Nitrosothiols.

    Science.gov (United States)

    Wang, Xin; Garcia, Carlos T; Gong, Guanyu; Wishnok, John S; Tannenbaum, Steven R

    2018-02-06

    S-Nitrosothiols (RSNOs) constitute a circulating endogenous reservoir of nitric oxide and have important biological activities. In this study, an online coupling of solid-phase derivatization (SPD) with liquid chromatography-mass spectrometry (LC-MS) was developed and applied in the analysis of low-molecular-mass RSNOs. A derivatizing-reagent-modified polymer monolithic column was prepared and adapted for online SPD-LC-MS. Analytes from the LC autosampler flowed through the monolithic column for derivatization and then directly into the LC-MS for analysis. This integration of the online derivatization, LC separation, and MS detection facilitated system automation, allowing rapid, laborsaving, and sensitive detection of RSNOs. S-Nitrosoglutathione (GSNO) was quantified using this automated online method with good linearity (R 2 = 0.9994); the limit of detection was 0.015 nM. The online SPD-LC-MS method has been used to determine GSNO levels in mouse samples, 138 ± 13.2 nM of endogenous GSNO was detected in mouse plasma. Besides, the GSNO concentrations in liver (64.8 ± 11.3 pmol/mg protein), kidney (47.2 ± 6.1 pmol/mg protein), heart (8.9 ± 1.8 pmol/mg protein), muscle (1.9 ± 0.3 pmol/mg protein), hippocampus (5.3 ± 0.9 pmol/mg protein), striatum (6.7 ± 0.6 pmol/mg protein), cerebellum (31.4 ± 6.5 pmol/mg protein), and cortex (47.9 ± 4.6 pmol/mg protein) were also successfully quantified. When the derivatization was performed within 8 min, followed by LC-MS detection, samples could be rapidly analyzed compared with the offline manual method. Other low-molecular-mass RSNOs, such as S-nitrosocysteine and S-nitrosocysteinylglycine, were captured by rapid precursor-ion scanning, showing that the proposed method is a potentially powerful tool for capture, identification, and quantification of RSNOs in biological samples.

  15. Determination of alkylphenols in water samples using liquid chromatography-tandem mass spectrometry after pre-column derivatization with dansyl chloride.

    Science.gov (United States)

    Pernica, Marek; Poloucká, Petra; Seifertová, Marta; Šimek, Zdeněk

    2015-10-23

    The present study describes an effect of reaction condition of pre-column derivatization of alkylphenols (APs): bisphenol A (BPA), 4-tert-octylphenol (4-t-OP), 4-octylphenol (4-OP), 4-n-nonylphenol (4-n-NP), and isomers of 4-nonylphenol (iso-NP) with 5-(dimethylamino) naphthalene-1-sulfonyl chloride (dansyl chloride, DNSC) on their LC-ESI-MS/MS determination in water samples. Chemical derivatization improves the sensitivity and selectivity of LC-MS/MS analysis. In principle, alkylphenols can be analyzed by LC-MS/MS without derivatization. However, pre-column derivatization of APs increases the sensitivity up to 1000 times in comparison with the analysis of underivatized alkylphenols. Reaction conditions affecting formation of the DNSC-derivatives, such as various solvent, reaction temperature, reaction time, DNSC concentration and pH values were tested. The most suitable conditions, in terms of achieving a high sensitivity, resulting from this study are: acetonitrile as reaction solvent, 60 min as reaction time, 60 °C as reaction temperature, pH values 10.5, 0.5 mg mL(-1) as DNSC concentration. Calibration curves are linear at least in the range of 1-1000 ng mL(-1), limits of detection (LOD) and limits of quantification (LOQ) ranging from 0.02 to 0.25 pg/injection and from 0.08 to 0.83 pg/injection, respectively. The improved procedure was successfully applied for the analysis of APs and BPA in real water samples. The median concentration of BPA and iso-NP obtained in bottled waters was 4.7 ng L(-1) and 33.5 ng L(-1), respectively. The median concentration of 4-t-OP was 1.3 ng L(-1.) Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Pentafluorobenzyl bromide-A versatile derivatization agent in chromatography and mass spectrometry: I. Analysis of inorganic anions and organophosphates.

    Science.gov (United States)

    Tsikas, Dimitrios

    2017-02-01

    Pentafluorobenzyl bromide (PFB-Br) is a versatile derivatization agent. It is widely used in chromatography and mass spectrometry since several decades. The bromide atom is largely the single leaving group of PFB-Br. It is substituted by wide a spectrum of nucleophiles in aqueous and non-aqueous systems to form electrically neutral, in most organic solvents soluble, generally thermally stable, volatile, strongly electron-capturing and ultraviolet light-absorbing derivatives. Because of these greatly favoured physicochemical properties, PFB-Br emerged an ideal derivatization agent for highly sensitive analysis of endogenous and exogenous substances including various inorganic and organic anions by electron capture detection or after electron-capture negative-ion chemical ionization in GC-MS. The present article attempts an appraisal of the utility of PFB-Br in analytical chemistry. It reviews and discusses papers dealing with the use of PFB-Br as the derivatization reagent in the qualitative and quantitative analysis of endogenous and exogenous inorganic anions in various biological samples, notably plasma, urine and saliva. These analytes include nitrite, nitrate, cyanide and dialkyl organophosphates. Special emphasis is given to mass spectrometry-based approaches and stable-isotope dilution techniques. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Picomolar concentrations of morphine in human urine determined by dansyl derivatization and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Lamshöft, Marc; Grobe, Nadja; Spiteller, Michael

    2011-04-15

    Morphine is present in varying amounts as an endogenous product in human urine. Derivatization of morphine contained in urine with dansyl chloride yields a known product, which can be quantified by liquid chromatography mass spectrometry with high selectivity and sensitivity. Urine samples of 51 healthy individuals were spiked with stable-isotope labeled morphine, hydrolyzed and subjected to solid phase extraction followed by derivatization of morphine with dansyl chloride. The dansyl derivatives of naturally occurring morphine and deuterated internal standard were then detected by liquid chromatography-triple quadrupole mass spectrometry. Using the [N-CD(3)]-labeled internal standard and solid-phase extraction, a limit of detection of 35 fmol/ml (10 pg/ml) and a limit of quantification of 87.5 fmol/ml (25 pg/ml) was determined for morphine in human urine. This new LC-MS/MS method allowed the detection of endogenous morphine in human urine of 51 volunteers with an average value of 156.4 fmol/ml (44.7 ng/ml). Copyright © 2011 Elsevier B.V. All rights reserved.

  18. [Determination of bisphenol A from toys and food contact materials by derivatization and gas chromatography-mass spectrometry].

    Science.gov (United States)

    Gao, Yonggang; Zhang, Yanyan; Gao, Jianguo; Zhang, Huiling; Zheng, Lisha; Chen, Jing

    2012-10-01

    A method was developed for the determination of bisphenol A (BPA) in toys and food contact materials. The BPA was extracted with Soxhlet extraction method from the sample and reacted with acetic anhydride. The final product was determined by gas chromatography-mass spectrometry (GC-MS). To achieve the optimum derivatization performance, the derivatization time and dosage of derivatization reagent etc. were investigated. Under the optimized experimental conditions, the final product was stable and the peak shape was good. The linearity of the derivative was good in the range of 0.05 to 50 mg/L with the correlation coefficient (r2) above 0.999. The recoveries ranged from 80% to 93% at the spiked levels of 0.05, 1.00, 10.00 mg/kg with the relative standard deviations (RSDs) less than 3.7%. The limit of detection (S/N = 3) was 10 microg/kg. The method is accurate and has high recovery. The method is suitable for the inspection of bisphenol A in toys and food contact materials.

  19. Comparison of derivatization/ionization techniques for liquid chromatography tandem mass spectrometry analysis of oxylipins.

    Science.gov (United States)

    Meckelmann, Sven W; Hellhake, Stefan; Steuck, Maryvonne; Krohn, Michael; Schebb, Nils Helge

    2017-05-01

    The performance of two derivatization and ionization techniques for the quantitative reversed phase liquid chromatography (LC)- mass spectrometry (MS) analysis of hydroxy fatty acids (OH-PUFA) in plasma was evaluated: One used AMPP (N-(4-aminomethylphenyl)pyridinium chloride) leading to a positive charged amid-derivate which can be detected by electrospray ionization (ESI)-MS. Second yielded penta fluorobenzyl bromide (PFB) ester derivates allowing detection in electron capture atmospheric pressure chemical ionization (ecAPCI)-MS. The sensitivity of detection of a comprehensive set of hydroxy fatty acids of n6- and n3- poly unsaturated fatty acids was investigated. On the SCIEX3200 MS the applied PFB derivatization led to poor limits of detection (LOD) of 10-100nM (0.1-1pmol/0.03-0.3ng on column). By contrast, AMPP derivatization led to a similar sensitivity compared to the standard ESI(-) of non derivatized analytes (LOD about 1nM (10fmol/3pg on column)). For several analytes, including 9-HETE, 11-HETE and 17-HDHA the AMPP derivatization improved sensitivity enabling their detection in human plasma. However, precision was reduced by AMPP derivatization and variation in IS recovery indicated a strong matrix influence on the MS-signal. In sum, with the instrumentation used, neither of these derivatization methods improves in our hands the LC-MS based quantification of oxylipins. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Reagent Precoated Targets for Rapid In-Tissue Derivatization of the Anti-Tuberculosis Drug Isoniazid Followed by MALDI Imaging Mass Spectrometry

    Science.gov (United States)

    Manier, M. Lisa; Reyzer, Michelle L.; Goh, Anne; Dartois, Veronique; Via, Laura E.; Barry, Clifton E.; Caprioli, Richard M.

    2011-08-01

    Isoniazid (INH) is an important component of front-line anti-tuberculosis therapy with good serum pharmacokinetics but unknown ability to penetrate tuberculous lesions. However, endogenous background interferences hinder our ability to directly analyze INH in tissues. Chemical derivatization has been successfully used to measure isoniazid directly from tissue samples using matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry (IMS). MALDI targets were pretreated with trans-cinnamaldehyde (CA) prior to mounting tissue slices. Isoniazid present in the tissues was efficiently derivatized and the INH-CA product measured by MS/MS. Precoating of MALDI targets allows the tissues to be directly thaw-mounted and derivatized, thus simplifying the preparation. A time-course series of tissues from tuberculosis infected/INH dosed animals were assayed and the MALDI MS/MS response correlates well with the amount of INH determined to be in the tissues by high-performance liquid chromatography (HPLC)-MS/MS.

  1. A rapid gas chromatographic injection-port derivatization method for the tandem mass spectrometric determination of patulin and 5-hydroxymethylfurfural in fruit juices.

    Science.gov (United States)

    Marsol-Vall, Alexis; Balcells, Mercè; Eras, Jordi; Canela-Garayoa, Ramon

    2016-07-01

    A novel method consisting of injection-port derivatization coupled to gas chromatography-tandem mass spectrometry is described. The method allows the rapid assessment of 5-hydroxymethylfurfural (HMF) and patulin content in apple and pear derivatives. The chromatographic separation of the compounds was achieved in a short chromatographic run (12.2min) suitable for routine controls of these compounds in the fruit juice industry. The optimal conditions for the injection-port derivatization were at 270°C, 0.5min purge-off, and a 1:2 sample:derivatization reagent ratio (v/v). These conditions represent an important saving in terms of derivatization reagent consumption and sample preparation time. Quality parameters were assessed for the target compounds, giving LOD of 0.7 and 1.6μg/kg and LOQ of 2 and 5μg/kg for patulin and HMF, respectively. These values are below the maximum patulin concentration in food products intended for infants and young children. Repeatability (%RSD n=5) was below 12% for both compounds. In addition, the method linearity ranged between 25 and 1000μg/kg and between 5 and 192μg/kg for HMF and patulin, respectively. Finally, the method was applied to study HMF and patulin content in various fruit juice samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Bulk derivatization and cation exchange restricted access media-based trap-and-elute liquid chromatography–mass spectrometry method for determination of trace estrogens in serum

    International Nuclear Information System (INIS)

    Beinhauer, Jana; Bian, Liangqiao; Fan, Hui; Šebela, Marek; Kukula, Maciej; Barrera, Jose A.

    2015-01-01

    Highlights: • Analysis of estrogens in small volume samples at low parts-per-trillion concentration. • Charged bulk derivatization facilitates on-line ion exchange sample preparation. • On-line WCX restricted access media traps analytes, but not proteins and lipids. • Complete preparation and LC–MS/MS analysis completed in 30 min/sample. - Abstract: Estrone (E1), estradiols (α/β-E2), and estriol (E3) are four major metabolically active estrogens exerting strong biological activities at very low circulating concentrations. This paper reports a sensitive and efficient method with automated, on-line clean-up and detection to determine trace estrogens in a small volume of serum samples using liquid chromatography–electrospray ionization–tandem mass spectrometry directly, without off-line liquid–liquid or solid-phase extraction pretreatments. Serum aliquots (charcoal stripped fetal bovine serum, 100 μL) were spiked with four estrogen standards and their corresponding isotope-labeled internal standards, then bulk derivatized with 2-fluoro-1-methyl-pyridium p-toluenesulfonate (2-FMP) to establish the calibration curves and perform method validation. Calibration was established in the concentration ranges of 5–1000 pg mL −1 , and demonstrated good linearity of R 2 from 0.9944 to 0.9997 for the four derivatized estrogens. The lower detection limits obtained were 3–7 pg mL −1 . Good accuracy and precision in the range of 86–112% and 2.3–11.9%, respectively, were observed for the quality control (QC) samples at low, medium, and high concentration levels. The stability tests showed that the derivatized serum samples were stable 8 h after derivatization at room temperature and at least to 48 h if stored at −20 °C. The method was applied to measure trace estrogens in real human and bovine serum samples, and three of four estrogen compounds studied were observed and quantified

  3. Determination of low-molecular-weight dicarboxylic acids in atmospheric aerosols by injection-port derivatization and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Hsu, Ching-Lin; Ding, Wang-Hsien

    2009-12-15

    A rapid and environmental-friendly injection-port derivatization with gas chromatography-mass spectrometry (GC-MS) method was developed to determine selected low-molecular weight (LMW) dicarboxylic acids (from C2 to C10) in atmospheric aerosol samples. The parameters related to the derivatization process (i.e., type of ion-pair reagent, injection-port temperature and concentration of ion-pair reagent) were optimized. Tetrabutylammonium hydroxide (TBA-OH) 20 mM in methanol gave excellent yield for di-butyl ester dicarboxylate derivatives at injection-port temperature at 300 degrees C. Solid-phase extraction (SPE) method instead of rotary evaporation was used to concentrate analytes from filter extracts. The recovery from filter extracts ranged from 78 to 95% with relative standard deviation (RSD) less than 12%. Limits of quantitation (LOQs) ranged from 25 to 250 pg/m(3). The concentrations of di-carboxylated C2-C5 and total C6-C10 in particles of atmospheric aerosols ranged from 91.9 to 240, 11.3 to 56.7, 9.2 to 49.2, 8.7 to 35.3 and n.d. to 37.8 ng/m(3), respectively. Oxalic acid (C2) was the dominant LMW-dicarboxylic acids detected in aerosol samples. The quantitative results were comparable to the results obtained by the off-line derivatization.

  4. The Influence of Mineralogy on Recovering Organic Acids from Mars Analogue Materials Using the One-Pot Derivatization Experiment on the Sample Analysis at Mars(SAM) Instrument Suite

    Science.gov (United States)

    Stalport, Fabien; Glavin, Daniel P.; Eigenbrode, J. L.; Bish, D.; Blake, D.; Coll, P.; Szopa, C.; Buch, A.; McAdam, A.; Dworkin, J. P.; hide

    2012-01-01

    The search for complex organic molecules on Mars, including important biomolecules such as amino acids and carboxylic acids, will require a chemical extraction and a derivatization step to transform these organic compounds into species that are sufficiently volatile to be detected by gas chromatography mass spectrometry (GCMS). We have developed a ''one-pot'' extraction and chemical derivatization protocol using N-methyl-N-(tert-butyldimethylsilyl) trifluoroacetamide (MTBSTFA) and dimethylformamide (DMF) for the Sample Analysis at Mars (SAM) experiment instrument suite on NASA's the Mars Science Laboratory (MSL) mission. The temperature and duration of the derivatization reaction, pre-concentration of chemical derivatives, and gas chromatographic separation parameters have been optimized under SAM instrument design constraints. MTBSTFA/DMF extraction and derivatization at 300 1C for several minutes of a variety of terrestrial Mars analog materials facilitated the detection of amino acids and carboxylic acids in a surface soil sample collected from the Atacama Desert and a carbonate-rich stromatolite sample from Svalbard. However, the rapid reaction of MTBSTFA with water in several analog materials that contained high abundances of hydrated minerals, and the possible deactivation of derivatized compounds by iron oxides, as detected by XRD/XRF using the CheMin field unit Terra, proved to be highly problematic for the direct extraction of organics using MTBSTFA. The combination of pyrolysis and two different wet-chemical derivatization methods employed by SAM should enable a wide range of organic compounds to be detected by GCMS if present on Mars.

  5. A novel method of liquid chromatography–tandem mass spectrometry combined with chemical derivatization for the determination of ribonucleosides in urine

    Energy Technology Data Exchange (ETDEWEB)

    Li, Shangfu [State Key Laboratory of Environmental and Biological Analysis, Department of Chemistry, Hong Kong Baptist University, Hong Kong (China); Jin, Yibao [Shenzhen Institute for Drug Control, Shenzhen 518055 (China); State Key Laboratory Breeding Base-Shenzhen Key Laboratory of Chemical Biology, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055 (China); Tang, Zhi; Lin, Shuhai [State Key Laboratory of Environmental and Biological Analysis, Department of Chemistry, Hong Kong Baptist University, Hong Kong (China); Liu, Hongxia [State Key Laboratory Breeding Base-Shenzhen Key Laboratory of Chemical Biology, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055 (China); Key Laboratory of Metabolomics at Shenzhen, Shenzhen 518055 (China); Jiang, Yuyang [State Key Laboratory Breeding Base-Shenzhen Key Laboratory of Chemical Biology, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055 (China); Cai, Zongwei, E-mail: zwcai@hkbu.edu.hk [State Key Laboratory of Environmental and Biological Analysis, Department of Chemistry, Hong Kong Baptist University, Hong Kong (China)

    2015-03-15

    Highlights: • A simple, robust and low-cost derivatization method was reported for ribonucleoside determination for the first time. • Improvement of separation and enhancement of sensitivity were achieved by using the derivatization approach. • Isotope labeling method with acetone-d{sub 6} and multivariate statistical analysis facilitated ribonucleoside identification. • Application of the method enabled the positive identification of 56 ribonucleosides. - Abstract: Ribonucleosides are the end products of RNA metabolism. These metabolites, especially the modified ribonucleosides, have been extensively evaluated as cancer-related biomarkers. However, the determination of urinary ribonucleosides is still a challenge due to their low abundance, high polarity and serious matrix interferences in urine samples. In this study, a derivatization method based on a chemical reaction between ribonucleosides and acetone to form acetonides was developed for the determination of urinary ribonucleosides. The derivative products, acetonides, were detected by using liquid chromatography–tandem mass spectrometry (LC–MS/MS). The methodological evaluation was performed by quantifying four nucleosides for linear range, average recovery, precision, accuracy and stability. The validated procedures were applied to screen modified ribonucleosides in urine samples. Improvement of separation and enhancement of sensitivity were obtained in the analysis. To identify ribonucleosides, inexpensive isotope labeling acetone (acetone-d{sub 6}) and label-free acetone were applied to form ordinary and deuterated acetonides, respectively. The two groups of samples were separated with orthogonal partial least squares (OPLS). The ordinary and deuterated pairs of acetonides were symmetrically distributed in the S-plot for easy and visual signal identification. After structural confirmation, a total of 56 ribonucleosides were detected, 52 of which were modified ribonucleosides. The application

  6. 1-(3-aminopropyl)-3-butylimidazolium bromide for carboxyl group derivatization: potential applications in high sensitivity peptide identification by mass spectrometry.

    Science.gov (United States)

    Qiao, Xiaoqiang; Zhou, Yuan; Hou, Chunyan; Zhang, Xiaodan; Yang, Kaiguang; Zhang, Lihua; Zhang, Yukui

    2013-03-01

    The cationic reagent 1-(3-aminopropyl)-3-butylimidazolium bromide (BAPI) was exploited for the derivatization of carboxyl groups on peptides. Nearly 100% derivatization efficiency was achieved with the synthetic peptide RVYVHPI (RI-7). Furthermore, the peptide derivative was stable in a 0.1% TFA/water solution or a 0.1% (v/v) TFA/acetonitrile/water solution for at least one week. The effect of BAPI derivatization on the ionization of the peptide RI-7 was further investigated, and the detection sensitivity was improved >42-fold via matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS), thus outperforming the commercial piperazine derivatization approach. Moreover, the charge states of the peptide were largely increased via BAPI derivatization by electrospray ionization (ESI) MS. The results indicate the potential merits of BAPI derivatization for high sensitivity peptide analysis by MS.

  7. Bulk derivatization and cation exchange restricted access media-based trap-and-elute liquid chromatography–mass spectrometry method for determination of trace estrogens in serum

    Energy Technology Data Exchange (ETDEWEB)

    Beinhauer, Jana [Department of Biochemistry, Faculty of Science, Palacký University, Šlechtitelů 11, CZ-783 71 Olomouc (Czech Republic); Centre of the Region Haná for Biotechnological and Agricultural Research - Department of Protein Biochemistry and Proteomics, Faculty of Science, Palacký University, Šlechtitelů 11, CZ-783 71 Olomouc (Czech Republic); Bian, Liangqiao [Shimadzu Center for Advanced Analytical Chemistry, The University of Texas at Arlington, Arlington, TX (United States); Shimadzu Institute for Research Technologies, The University of Texas at Arlington, Arlington, TX (United States); Fan, Hui [Department of Chemistry and Biochemistry, The University of Texas at Arlington, Arlington, TX (United States); Šebela, Marek [Department of Biochemistry, Faculty of Science, Palacký University, Šlechtitelů 11, CZ-783 71 Olomouc (Czech Republic); Centre of the Region Haná for Biotechnological and Agricultural Research - Department of Protein Biochemistry and Proteomics, Faculty of Science, Palacký University, Šlechtitelů 11, CZ-783 71 Olomouc (Czech Republic); Kukula, Maciej [Shimadzu Center for Advanced Analytical Chemistry, The University of Texas at Arlington, Arlington, TX (United States); Shimadzu Institute for Research Technologies, The University of Texas at Arlington, Arlington, TX (United States); Barrera, Jose A. [Shimadzu Institute for Research Technologies, The University of Texas at Arlington, Arlington, TX (United States); and others

    2015-02-09

    Highlights: • Analysis of estrogens in small volume samples at low parts-per-trillion concentration. • Charged bulk derivatization facilitates on-line ion exchange sample preparation. • On-line WCX restricted access media traps analytes, but not proteins and lipids. • Complete preparation and LC–MS/MS analysis completed in 30 min/sample. - Abstract: Estrone (E1), estradiols (α/β-E2), and estriol (E3) are four major metabolically active estrogens exerting strong biological activities at very low circulating concentrations. This paper reports a sensitive and efficient method with automated, on-line clean-up and detection to determine trace estrogens in a small volume of serum samples using liquid chromatography–electrospray ionization–tandem mass spectrometry directly, without off-line liquid–liquid or solid-phase extraction pretreatments. Serum aliquots (charcoal stripped fetal bovine serum, 100 μL) were spiked with four estrogen standards and their corresponding isotope-labeled internal standards, then bulk derivatized with 2-fluoro-1-methyl-pyridium p-toluenesulfonate (2-FMP) to establish the calibration curves and perform method validation. Calibration was established in the concentration ranges of 5–1000 pg mL{sup −1}, and demonstrated good linearity of R{sup 2} from 0.9944 to 0.9997 for the four derivatized estrogens. The lower detection limits obtained were 3–7 pg mL{sup −1}. Good accuracy and precision in the range of 86–112% and 2.3–11.9%, respectively, were observed for the quality control (QC) samples at low, medium, and high concentration levels. The stability tests showed that the derivatized serum samples were stable 8 h after derivatization at room temperature and at least to 48 h if stored at −20 °C. The method was applied to measure trace estrogens in real human and bovine serum samples, and three of four estrogen compounds studied were observed and quantified.

  8. Determination of BMAA and three alkaloid cyanotoxins in lake water using dansyl chloride derivatization and high-resolution mass spectrometry.

    Science.gov (United States)

    Roy-Lachapelle, Audrey; Solliec, Morgan; Sauvé, Sébastien

    2015-07-01

    A new analytical method was developed for the detection of alkaloid cyanotoxins in harmful algal blooms. The detection of the nonproteinogenic amino acid β-N-methylamino-L-alanine (BMAA) and two of its conformation isomers, 2,4-diaminobutyric acid (DAB) and N-(2-aminoethyl) glycine (AEG), as well as three alkaloid cyanotoxins, anatoxin-a (ANA-a), cylindrospermopsin (CYN), and saxitoxin (STX), is presented. The use of a chemical derivatization with dansyl chloride (DNS) allows easier separation with reversed phase liquid chromatography. Detection with high-resolution mass spectrometry (HRMS) with the Q-Exactive enables high selectivity with specific fragmentation as well as exact mass detection, reducing considerably the possibilities of isobaric interferences. Previous to analysis, a solid phase extraction (SPE) step is used for purification and preconcentration. After DNS derivatization, samples are submitted to ultra high-performance liquid chromatography coupled with heated electrospray ionisation and the Q-Exactive mass spectrometer (UHPLC-HESI-HRMS). With an internal calibration using isotopically-labeled DAB-D3, the method was validated with good linearity (R (2)  > 0.998), and method limits of detection and quantification (MLD and MLQ) for target compounds ranged from 0.007 to 0.01 μg L(-1) and from 0.02 to 0.04 μg L(-1), respectively. Accuracy and within-day/between-days variation coefficients were below 15%. SPE recovery values ranged between 86 and 103%, and matrix effects recovery values ranged between 75 and 96%. The developed analytical method was successfully validated with 12 different lakes samples, and concentrations were found ranging between 0.009 and 0.3 μg L(-1) except for STX which was not found in any sample.

  9. Simultaneous quantitation of hydrazine and acetylhydrazine in human plasma by high performance liquid chromatography-tandem mass spectrometry after derivatization with p-tolualdehyde.

    Science.gov (United States)

    Song, Lu; Gao, Dan; Li, Shangfu; Wang, Yanwei; Liu, Hongxia; Jiang, Yuyang

    2017-09-15

    A high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for simultaneous quantitative analysis of hydrazine and acetylhydrazine in human plasma based on the strategy of p-tolualdehyde derivatization. The derivatization reactions were easily realized by ultrasonic manipulation for 40min. Good separation of the derivatization products was achieved using a C 18 column by gradient elution. The optimized mass transition ion-pairs (m/z) monitored for the two hydrazine derivatives were m/z 237.1≫>119.9 and m/z 176.9≫>117.8, respectively. The limit of detection (LOD) and limit of quantification (LOQ) for hydrazine were 0.002 and 0.005ngmL -1 separately. And they were 0.03 and 0.05ngmL -1 for acetylhydrazine, respectively. The linear range was 0.005-50ngmL -1 for hydrazine and 0.05-500ngmL -1 for acetylhydrazine with R 2 greater than 0.999. The recovery range was determined to be 95.38-108.12% with the relative standard deviation (RSD) in the range of 1.24-14.89%. The method was successfully applied to detect 30 clinical plasma samples of pulmonary tuberculosis patients treated with isoniazid. The concentrations were from 0.04-1.99ngmL -1 for hydrazine and 0.06-142.43ngmL -1 for acetylhydrazine. The results indicated that our developed method had the potential for the detection of hydrazine toxicology in complex biological samples. Furthermore, the method has an important significance to clinical treatment with drugs. Copyright © 2017. Published by Elsevier B.V.

  10. Analysis of L-serine-O-phosphate in cerebrospinal spinal fluid by derivatization-liquid chromatography/mass spectrometry.

    Science.gov (United States)

    McNaney, Colleen A; Benitex, Yulia; Luchetti, David; Labasi, Jeffrey M; Olah, Timothy V; Morgan, Daniel G; Drexler, Dieter M

    2014-05-01

    L-serine-O-phosphate (L-SOP), the precursor of L-serine, is a potent agonist against the group III metabotropic glutamate receptors (mGluRs) and, thus, is of interest as a potential biomarker for monitoring modulation of neurotransmitter release. So far, no reports are available on the analysis of L-SOP in cerebrospinal fluid (CSF). Here a novel method is presented to determine L-SOP levels in CSF employing precolumn derivatization with (5-N-succinimidoxy-5-oxopentyl)triphenylphosphonium bromide (SPTPP) coupled to liquid chromatography/mass spectrometry (derivatization-LC/MS, d-LC/MS). Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Simultaneous Determination of Food-Related Biogenic Amines and Precursor Amino Acids Using in Situ Derivatization Ultrasound-Assisted Dispersive Liquid-Liquid Microextraction by Ultra-High-Performance Liquid Chromatography Tandem Mass Spectrometry.

    Science.gov (United States)

    He, Yongrui; Zhao, Xian-En; Wang, Renjun; Wei, Na; Sun, Jing; Dang, Jun; Chen, Guang; Liu, Zhiqiang; Zhu, Shuyun; You, Jinmao

    2016-11-02

    A simple, rapid, sensitive, selective, and environmentally friendly method, based on in situ derivatization ultrasound-assisted dispersive liquid-liquid microextraction (in situ DUADLLME) coupled with ultra-high-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) using multiple reaction monitoring (MRM) mode has been developed for the simultaneous determination of food-related biogenic amines and amino acids. A new mass-spectrometry-sensitive derivatization reagent 4'-carbonyl chloride rosamine (CCR) was designed, synthesized, and first reported. Parameters and conditions of in situ DUADLLME and UHPLC-MS/MS were optimized in detail. Under the optimized conditions, the in situ DUADLLME was completed speedily (within 1 min) with high derivatization efficiencies (≥98.5%). With the cleanup and concentration of microextraction step, good analytical performance was obtained for the analytes. The results showed that this method was accurate and practical for quantification of biogenic amines and amino acids in common food samples (red wine, beer, wine, cheese, sausage, and fish).

  12. Method for the determination of carboxylic acids in industrial effluents using dispersive liquid-liquid microextraction with injection port derivatization gas chromatography-mass spectrometry.

    Science.gov (United States)

    Makoś, Patrycja; Fernandes, Andre; Boczkaj, Grzegorz

    2017-09-29

    The paper presents a new method for the determination of 15 carboxylic acids in samples of postoxidative effluents from the production of petroleum bitumens using ion-pair dispersive liquid-liquid microextraction and gas chromatography coupled to mass spectrometry with injection port derivatization. Several parameters related to the extraction and derivatization efficiency were optimized. Under optimized experimental conditions, the obtained limit of detection and quantification ranged from 0.0069 to 1.12μg/mL and 0.014 to 2.24μg/mL, respectively. The precision (RSD ranged 1.29-6.42%) and recovery (69.43-125.79%) were satisfactory. Nine carboxylic acids at concentrations ranging from 0.10μg/mL to 15.06μg/mL were determined in the raw wastewater and in samples of effluents treated by various oxidation methods. The studies revealed a substantial increase of concentration of benzoic acids, in samples of wastewater after treatment, which confirms the need of carboxylic acids monitoring during industrial effluent treatment processes. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. A microfluidic device for the automated derivatization of free fatty acids to fatty acid methyl esters.

    Science.gov (United States)

    Duong, Cindy T; Roper, Michael G

    2012-02-21

    Free fatty acid (FFA) compositions are examined in feedstock for biodiesel production, as source-specific markers in soil, and because of their role in cellular signaling. However, sample preparation of FFAs for gas chromatography-mass spectrometry (GC-MS) analysis can be time and labor intensive. Therefore, to increase sample preparation throughput, a glass microfluidic device was developed to automate derivatization of FFAs to fatty acid methyl esters (FAMEs). FFAs were delivered to one input of the device and methanolic-HCl was delivered to a second input. FAME products were produced as the reagents traversed a 29 μL reaction channel held at 55 °C. A Design of Experiment protocol was used to determine the combination of derivatization time (T(der)) and ratio of methanolic-HCl:FFA (R(der)) that maximized the derivatization efficiencies of tridecanoic acid and stearic acid to their methyl ester forms. The combination of T(der) = 0.8 min and R(der) = 4.9 that produced optimal derivatization conditions for both FFAs within a 5 min total sample preparation time was determined. This combination of T(der) and R(der) was used to derivatize 12 FFAs with a range of derivatization efficiencies from 18% to 93% with efficiencies of 61% for tridecanoic acid and 84% for stearic acid. As compared to a conventional macroscale derivatization of FFA to FAME, the microfluidic device decreased the volume of methanolic-HCl and FFA by 20- and 1300-fold, respectively. The developed microfluidic device can be used for automated preparation of FAMEs to analyze the FFA compositions of volume-limited samples.

  14. Determination of cholesterol and four phytosterols in foods without derivatization by gas chromatography-tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Yan-Zong Chen

    2015-12-01

    Full Text Available In this study, a method for determination of cholesterol and four phytosterols by gas chromatography coupled with electron impact ionization mode–tandem mass spectrometry without derivatization in general food was developed. The sample was saponified with 7.5% KOH in methanol. After heating on hot plate and reflux for 60 minutes, the saponified portion was extracted with n-hexane/petroleum ether (50:50, v/v. The extracts were evaporated with rotary evaporator and then redissolved with tetrahydrofuran. The tetrahydrofuran layer was transferred into an injection vial and analyzed by gas chromatography on a 30 m VF-5 column. Limit of quantification was 2 mg/kg. Recoveries of cholesterol and four phytosterols from general food were between 91% and 100%.

  15. Automated determination of aliphatic primary amines in wastewater by simultaneous derivatization and headspace solid-phase microextraction followed by gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Llop, Anna; Pocurull, Eva; Borrull, Francesc

    2010-01-22

    This paper presents a fully automated method for determining ten primary amines in wastewater at ng/L levels. The method is based on simultaneous derivatization with pentafluorobenzaldehyde (PFBAY) and headspace solid-phase microextraction (HS-SPME) followed by gas chromatography coupled to ion trap tandem mass spectrometry (GC-IT-MS-MS). The influence of main factors on the efficiency of derivatization and of HS-SPME is described in detail and optimized by a central composite design. For all species, the highest enrichment factors were achieved using a 85 microm polyacrylate (PA) fiber exposed in the headspace of stirred water samples (750 rpm) at pH 12, containing 360 g/L of NaCl, at 40 degrees C for 15 min. Under optimized conditions, the proposed method achieved detection limits ranging from 10 to 100 ng/L (except for cyclohexylamine). The optimized method was then used to determine the presence of primary amines in various types of wastewater samples, such as influent and effluent wastewater from municipal and industrial wastewater treatment plants (WWTPs) and a potable water treatment plant. Although the analysis of these samples revealed the presence of up to 1500 microg/L of certain primary amines in influent industrial wastewater, the concentration of these compounds in the effluent and in municipal and potable water was substantially lower, at low microg/L levels. The new derivatization-HS-SPME-GC-IT-MS-MS method is suitable for the fast, reliable and inexpensive determination of primary amines in wastewater in an automated procedure. Copyright 2009 Elsevier B.V. All rights reserved.

  16. Quantification of peramivir in dog plasma by liquid chromatography/tandem mass spectrometry employing precolumn derivatization.

    Science.gov (United States)

    Li, Xin; Li, Ying; Wang, Juan; Wang, Lili; Zhong, Wu; Ruan, Jinxiu; Zhang, Zhenqing

    2014-01-01

    Peramivir is a novel influenza neuraminidase inhibitor used for anti-influenza. In this article, a novel method was developed to determine peramivir in dog plasma using a derivatization treatment step to increase the retention time and enhance the signal intensity. The sample preparation consisted of a protein precipitation extraction followed by derivatization with 10M hydrochloric acid-methanol (10:90, v/v) and determined by liquid chromatography coupled with tandem mass spectrometry. The selected reaction monitoring mode of the positive ion was performed and the precursor to the product ion transitions of m/z 343→284 and m/z 299→152 were used to measure the derivative of peramivir and Ro 64-0802 (internal standard, an active metabolite of oseltamivir). The chromatographic separation was achieved using a ZORBAX RX-C8 (2.0mm×150mm×5μm) analytical column with an isocratic mobile phase composed of acetonitrile-water-formic acid (30:70:0.1, v/v/v, 0.2mL/min). The method was linear over a concentration range of 0.25-250ng/mL. The average intra-day/inter-day precision values were 4.04-8.17% and 3.02-7.08%, respectively, while the average accuracy value was 93.99-106.48%. This method has been successfully applied to the preclinical dog research of peramivir following intragastric administration. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Monolithic silica spin column extraction and simultaneous derivatization of amphetamines and 3,4-methylenedioxyamphetamines in human urine for gas chromatographic-mass spectrometric detection

    International Nuclear Information System (INIS)

    Nakamoto, Akihiro; Nishida, Manami; Saito, Takeshi; Kishiyama, Izumi; Miyazaki, Shota; Murakami, Katsunori; Nagao, Masataka; Namura, Akira

    2010-01-01

    A simple, sensitive, and specific method with gas chromatography-mass spectrometry was developed for simultaneous extraction and derivatization of amphetamines (APs) and 3,4-methylenedioxyamphetamines (MDAs) in human urine by using a monolithic silica spin column. All the procedures, such as sample loading, washing, and elution were performed by centrifugation. APs and MDAs in urine were adsorbed on the monolithic silica and derivatized with propyl chloroformate in the column. Methamphetamine-d 5 was used as an internal standard. The linear ranges were 0.01-5.0 μg mL -1 for methamphetamine (MA) and 3,4-methylenedioxymethamphetamine (MDMA) and 0.02-5.0 μg mL -1 for amphetamine (AP) and 3,4-methylenedioxyamphetamine (MDA) (coefficient of correlation ≥0.995). The recovery of APs and MDAs in urine was 84-94%, and the relative standard deviation of the intra- and interday reproducibility for urine samples containing 0.1, 1.0, and 4.0 μg mL -1 of APs and MDAs ranged from 1.4% to 13.6%. The lowest detection limit (signal-to-noise ratio ≥ 3) in urine was 5 ng mL -1 for MA and MDMA and 10 ng mL -1 for AP and MDA. The proposed method can be used to perform simultaneous extraction and derivatization on spin columns that have been loaded with a small quantity of solvent by using centrifugation.

  18. Monolithic silica spin column extraction and simultaneous derivatization of amphetamines and 3,4-methylenedioxyamphetamines in human urine for gas chromatographic-mass spectrometric detection

    Energy Technology Data Exchange (ETDEWEB)

    Nakamoto, Akihiro [Scientific Investigation Laboratory, Hiroshima Prefectural Police Headquarters, Kohnan 2-26-3, Naka-ku, Hiroshima 730-0825 (Japan); Nishida, Manami [Hiroshima University Technical Center, Kasumi 1-2-3, Minami-ku, Hiroshima 734-8551 (Japan); Saito, Takeshi [Department of Emergency and Critical Care Medicine, Tokai University School of Medicine, Shimokasuya 143, Isehara, Kanagawa 259-1143 (Japan); Kishiyama, Izumi; Miyazaki, Shota [GL Sciences Inc., Sayamagahara 237-2, Iruma, Saitama 358-0032 (Japan); Murakami, Katsunori [Scientific Investigation Laboratory, Hiroshima Prefectural Police Headquarters, Kohnan 2-26-3, Naka-ku, Hiroshima 730-0825 (Japan); Nagao, Masataka [Department of Forensic Medicine, Graduate School of Biomedical Sciences, Hiroshima University, Kasumi 1-2-3, Minami-ku, Hiroshima 734-8551 (Japan); Namura, Akira, E-mail: namera@hiroshima-u.ac.jp [Department of Forensic Medicine, Graduate School of Biomedical Sciences, Hiroshima University, Kasumi 1-2-3, Minami-ku, Hiroshima 734-8551 (Japan)

    2010-02-19

    A simple, sensitive, and specific method with gas chromatography-mass spectrometry was developed for simultaneous extraction and derivatization of amphetamines (APs) and 3,4-methylenedioxyamphetamines (MDAs) in human urine by using a monolithic silica spin column. All the procedures, such as sample loading, washing, and elution were performed by centrifugation. APs and MDAs in urine were adsorbed on the monolithic silica and derivatized with propyl chloroformate in the column. Methamphetamine-d{sub 5} was used as an internal standard. The linear ranges were 0.01-5.0 {mu}g mL{sup -1} for methamphetamine (MA) and 3,4-methylenedioxymethamphetamine (MDMA) and 0.02-5.0 {mu}g mL{sup -1} for amphetamine (AP) and 3,4-methylenedioxyamphetamine (MDA) (coefficient of correlation {>=}0.995). The recovery of APs and MDAs in urine was 84-94%, and the relative standard deviation of the intra- and interday reproducibility for urine samples containing 0.1, 1.0, and 4.0 {mu}g mL{sup -1} of APs and MDAs ranged from 1.4% to 13.6%. The lowest detection limit (signal-to-noise ratio {>=} 3) in urine was 5 ng mL{sup -1} for MA and MDMA and 10 ng mL{sup -1} for AP and MDA. The proposed method can be used to perform simultaneous extraction and derivatization on spin columns that have been loaded with a small quantity of solvent by using centrifugation.

  19. Monolithic silica spin column extraction and simultaneous derivatization of amphetamines and 3,4-methylenedioxyamphetamines in human urine for gas chromatographic-mass spectrometric detection.

    Science.gov (United States)

    Nakamoto, Akihiro; Nishida, Manami; Saito, Takeshi; Kishiyama, Izumi; Miyazaki, Shota; Murakami, Katsunori; Nagao, Masataka; Namura, Akira

    2010-02-19

    A simple, sensitive, and specific method with gas chromatography-mass spectrometry was developed for simultaneous extraction and derivatization of amphetamines (APs) and 3,4-methylenedioxyamphetamines (MDAs) in human urine by using a monolithic silica spin column. All the procedures, such as sample loading, washing, and elution were performed by centrifugation. APs and MDAs in urine were adsorbed on the monolithic silica and derivatized with propyl chloroformate in the column. Methamphetamine-d(5) was used as an internal standard. The linear ranges were 0.01-5.0 microg mL(-1) for methamphetamine (MA) and 3,4-methylenedioxymethamphetamine (MDMA) and 0.02-5.0 microg mL(-1) for amphetamine (AP) and 3,4-methylenedioxyamphetamine (MDA) (coefficient of correlation > or = 0.995). The recovery of APs and MDAs in urine was 84-94%, and the relative standard deviation of the intra- and interday reproducibility for urine samples containing 0.1, 1.0, and 4.0 microg mL(-1) of APs and MDAs ranged from 1.4% to 13.6%. The lowest detection limit (signal-to-noise ratio > or = 3) in urine was 5 ng mL(-1) for MA and MDMA and 10 ng mL(-1) for AP and MDA. The proposed method can be used to perform simultaneous extraction and derivatization on spin columns that have been loaded with a small quantity of solvent by using centrifugation. Copyright 2009 Elsevier B.V. All rights reserved.

  20. Sampling and Analytical Method for Alpha-Dicarbonyl Flavoring Compounds via Derivatization with o-Phenylenediamine and Analysis Using GC-NPD

    Directory of Open Access Journals (Sweden)

    Stephanie M. Pendergrass

    2016-01-01

    Full Text Available A novel methodology is described for the sampling and analysis of diacetyl, 2,3-pentanedione, 2,3-hexanedione, and 2,3-heptanedione. These analytes were collected on o-phenylenediamine-treated silica gel tubes and quantitatively recovered as the corresponding quinoxaline derivatives. After derivatization, the sorbent was desorbed in 3 mL of ethanol solvent and analyzed using gas chromatography/nitrogen-phosphorous detection (GC/NPD. The limits of detection (LOD achieved for each analyte were determined to be in the range of 5–10 nanograms/sample. Evaluation of the on-tube derivatization procedure indicated that it is unaffected by humidities ranging from 20% to 80% and that the derivatization procedure was quantitative for analyte concentrations ranging from 0.1 μg to approximately 500 μg per sample. Storage stability studies indicated that the derivatives were stable for 30 days when stored at both ambient and refrigerated temperatures. Additional studies showed that the quinoxaline derivatives were quantitatively recovered when sampling up to a total volume of 72 L at a sampling rate of 50 cc/min. This method will be important to evaluate and monitor worker exposures in the food and flavoring industry. Samples can be collected over an 8-hour shift with up to 288 L total volume collected regardless of time, sampling rate, and/or the effects of humidity.

  1. Fast derivatization of fatty acids in different meat samples for gas chromatography analysis.

    Science.gov (United States)

    Figueiredo, Ingrid Lima; Claus, Thiago; Oliveira Santos Júnior, Oscar; Almeida, Vitor Cinque; Magon, Thiago; Visentainer, Jesuí Vergilio

    2016-07-22

    In order to analyze the composition of fatty acids employing gas chromatography as the separation method, a derivatization of lipids using esterification and transesterification reactions is needed. The methodologies currently available are time consuming and use large amounts of sample and reagents. Thus, this work proposes a new procedure to carry out the derivatization of fatty acids without the need for prior extraction of lipids. The use of small amounts of sample (100mg) allows the analysis to be performed in specific parts of animals, in most cases without having them slaughtered. Another benefit is the use of small amounts of reagents (only 2mL of NaOH/Methanol and H2SO4/Methanol). The use of an experimental design procedure (Design Expert software) allows the optimization of the alkaline and acid reaction times. The procedure was validated for five minutes in both steps. The method was validated for bovine fat, beef, chicken, pork, fish and shrimp meats. The results for the merit figures of accuracy (from 101.07% to 109.18%), precision (RSDintra-day (from 0.65 to 3.93%), RSDinter-day (from 1.57 to 5.22%)), linearity (R(2)=0.9864) and robustness confirmed that the new method is satisfactory within the linear range of 2-30% of lipids in the sample. Besides the benefits of minimizing the amount of samples and reagents, the procedure enables gas chromatography sample preparation in a very short time compared with traditional procedures. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Analysis of carbonyl compounds via headspace solid-phase microextraction with on-fiber derivatization and gas chromatographic-ion trap tandem mass spectrometric determination of their O-(2,3,4,5,6-pentafluorobenzyl)oxime derivatives

    Energy Technology Data Exchange (ETDEWEB)

    Schmarr, Hans-Georg [Dienstleistungszentrum Laendlicher Raum (DLR) Rheinpfalz, Breitenweg 71, D-67435 Neustadt an der Weinstrasse (Germany)], E-mail: hans-georg.schmarr@dlr.rlp.de; Potouridis, Theodoros; Ganss, Sebastian; Sang, Wei; Koepp, Benedikt; Bokuz, Ursula; Fischer, Ulrich [Dienstleistungszentrum Laendlicher Raum (DLR) Rheinpfalz, Breitenweg 71, D-67435 Neustadt an der Weinstrasse (Germany)

    2008-06-09

    An improved method for the analysis of carbonyls is described utilizing a headspace solid-phase microextraction (HS-SPME) step and on-fiber derivatization with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBHA) hydrochloride. Thermal desorption of the oxime derivatives formed on the fiber is followed by gas chromatographic separation coupled to an ion trap tandem mass spectrometer (GC-ITMS). Selecting specific fragment ions within the electron ionization (EI{sup +}) mass spectra of these oxime derivatives as precursor ions for MS-MS fragmentation provides a suitable method for the target analysis of individual carbonyl classes, such as alkanals, (E)-2-alkenals, (E,E)-2,4-alkadienals, and others. Retention indices on polar as well as on apolar stationary phases along with EI{sup +} mass spectra patterns are presented for a large set of oxime derivatives, giving valuable information needed for unambiguous assignment of substances in complex sample matrices. The fast sample preparation and derivatization step via HS-SPME can be automated and is applicable to a variety of biological samples and foodstuffs, allowing rapid and sensitive screening analyses of important aldehydic biomarkers and aroma active compounds.

  3. Study of disulfide reduction and alkyl chloroformate derivatization of plasma sulfur amino acids using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Svagera, Zdeněk; Hanzlíková, Dagmar; Simek, Petr; Hušek, Petr

    2012-03-01

    Four disulfide-reducing agents, dithiothreitol (DTT), 2,3-dimercaptopropanesulfonate (DMPS), and the newly tested 2-mercaptoethanesulfonate (MESNA) and Tris(hydroxypropyl)phosphine (THP), were investigated in detail for release of sulfur amino acids in human plasma. After protein precipitation with trichloroacetic acid (TCA), the plasma supernatant was treated with methyl, ethyl, or propyl chloroformate via the well-proven derivatization-extraction technique and the products were subjected to gas chromatographic-mass spectrometric (GC-MS) analysis. All the tested agents proved to be rapid and effective reducing agents for the assay of plasma thiols. When compared with DTT, the novel reducing agents DMPS, MESNA, and THP provided much cleaner extracts and improved analytical performance. Quantification of homocysteine, cysteine, and methionine was performed using their deuterated analogues, whereas other analytes were quantified by means of 4-chlorophenylalanine. Precise and reliable assay of all examined analytes was achieved, irrespective of the chloroformate reagent used. Average relative standard deviations at each analyte level were ≤6%, quantification limits were 0.1-0.2 μmol L(-1), recoveries were 94-121%, and linearity was over three orders of magnitude (r(2) equal to 0.997-0.998). Validation performed with the THP agent and propyl chloroformate derivatization demonstrated the robustness and reliability of this simple sample-preparation methodology.

  4. An optimized two-step derivatization method for analyzing diethylene glycol ozonation products using gas chromatography and mass spectrometry.

    Science.gov (United States)

    Yu, Ran; Duan, Lei; Jiang, Jingkun; Hao, Jiming

    2017-03-01

    The ozonation of hydroxyl compounds (e.g., sugars and alcohols) gives a broad range of products such as alcohols, aldehydes, ketones, and carboxylic acids. This study developed and optimized a two-step derivatization procedure for analyzing polar products of aldehydes and carboxylic acids from the ozonation of diethylene glycol (DEG) in a non-aqueous environment using gas chromatography-mass spectrometry. Experiments based on Central Composite Design with response surface methodology were carried out to evaluate the effects of derivatization variables and their interactions on the analysis. The most desirable derivatization conditions were reported, i.e., oximation was performed at room temperature overnight with the o-(2,3,4,5,6-pentafluorobenzyl) hydroxyl amine to analyte molar ratio of 6, silylation reaction temperature of 70°C, reaction duration of 70min, and N,O-bis(trimethylsilyl)-trifluoroacetamide volume of 12.5μL. The applicability of this optimized procedure was verified by analyzing DEG ozonation products in an ultrafine condensation particle counter simulation system. Copyright © 2016. Published by Elsevier B.V.

  5. HPLC determination of chlorine in air and water samples following precolumn derivatization to 4-bromoacetanilide

    Energy Technology Data Exchange (ETDEWEB)

    Jain, A. (Rani Durgavati Univ., Jabalpur (India). Dept. of Chemistry); Verma, K.K. (Rani Durgavati Univ., Jabalpur (India). Dept. of Chemistry)

    1993-11-01

    Chlorine has been determined in air and water samples by a rapid and sensitive method entailing precolumn derivatization to 4-bromoacetanilide. A mixed potassium bromide - acetanilide reagent was used as a trapping agent for chlorine in air, and for its derivatization. The 4-bromoacetanilide formed was determined by reversed-phase HPLC on an ODS column, using methanol-water, 65:35 (v/v) as mobile phase; detection was at 240 nm. A rectilinear calibration graph was obtained for the range 0.1-30 [mu]g mL[sup -1] chlorine; the limit of detection found to be 0.01 [mu]g mL[sup -1]. The precolumn derivative has been found to have a shelf-life of at least 21 days; this enables the use of the method for samples transported from the field to the analytical laboratory, or the testing of a variety of conditions for chlorine scrubbing studies without the need for immediate analysis of samples. Humic substances do not cause any interference with the proposed method and the presence of nitrite does not lead to artificially high results and consequent misleading conclusions of the presence of high levels of chlorine. (orig.)

  6. HPLC determination of chlorine in air and water samples following precolumn derivatization to 4-bromoacetanilide

    International Nuclear Information System (INIS)

    Jain, A.; Verma, K.K.

    1993-01-01

    Chlorine has been determined in air and water samples by a rapid and sensitive method entailing precolumn derivatization to 4-bromoacetanilide. A mixed potassium bromide - acetanilide reagent was used as a trapping agent for chlorine in air, and for its derivatization. The 4-bromoacetanilide formed was determined by reversed-phase HPLC on an ODS column, using methanol-water, 65:35 (v/v) as mobile phase; detection was at 240 nm. A rectilinear calibration graph was obtained for the range 0.1-30 μg mL -1 chlorine; the limit of detection found to be 0.01 μg mL -1 . The precolumn derivative has been found to have a shelf-life of at least 21 days; this enables the use of the method for samples transported from the field to the analytical laboratory, or the testing of a variety of conditions for chlorine scrubbing studies without the need for immediate analysis of samples. Humic substances do not cause any interference with the proposed method and the presence of nitrite does not lead to artificially high results and consequent misleading conclusions of the presence of high levels of chlorine. (orig.)

  7. Determination of low-molecular-weight dicarboxylic acids in atmospheric aerosols by injection-port derivatization and gas chromatography-mass spectrometry

    Science.gov (United States)

    Ding, W.; Hsu, C.

    2008-12-01

    Currently, the investigations on aerosol water-soluble organic compounds (WSOCs) formed by burning biomass have become increasingly concerned with the role of these compounds in atmospheric chemistry and their effect on climate, because they have great potential to influence cloud formation, precipitation, and climate on both global and regional scales. Of these compounds, low-molecular weight (LMW) dicarboxylic acids (from C2 to C10) have attracted the most interest because of their properties as specific tracers for the burning of biomass. In this study, a modified injection-port derivatization and gas chromatography - mass spectrometry method was developed and evaluated for rapid determination of LMW dicarboxylic acids in atmospheric aerosol samples. The parameters related to the derivatization process (i.e., type of ion-pair reagent, injection-port temperature and concentration of ion-pair reagent) were optimized. Tetrabutylammonium hydroxide (TBA-OH) dissolved in methanol used as the ion-pair solution gave excellent yield for di-butyl ester low-molecular weight derivatives. Solid-phase extraction method instead of rotary evaporation was used to concentrate analytes from filter extracts. The recovery from filter extracts ranged from 67 to 86% with relative standard deviation (RSD) less than 13%. The concentrations of dicarboxylated C2, C3, C4, C5 and C6-C10 in atmospheric aerosols ranged from 91-240 ng/m3, 11-56 ng/m3, 12-49 ng/m3, 8-35 ng/m3 and n.d. to 17 ng/m3, respectively. Oxalic (C2) acid was the dominant dicarboxylic acids detected in aerosol samples. The total concentrations of the LMW dicarboxylic acids (from C2 to C10) correspond to 2.2 to 2.6% of the total aerosol mass.

  8. Histamine and tele-methylhistamine quantification in cerebrospinal fluid from narcoleptic subjects by liquid chromatography tandem mass spectrometry with precolumn derivatization.

    Science.gov (United States)

    Croyal, Mikaël; Dauvilliers, Yves; Labeeuw, Olivier; Capet, Marc; Schwartz, Jean-Charles; Robert, Philippe

    2011-02-01

    An ultra-performance liquid chromatography tandem mass spectrometry (UPLC™-MS/MS) assay was developed for the simultaneous analysis of histamine, its major metabolite tele-methylhistamine, and an internal standard (N-tele-(R)-α-dimethylhistamine) from human cerebrospinal fluid (CSF) samples. The method involves derivatization of primary amines with 4-bromobenzenesulfonyl chloride and subsequent analysis by reversed phase liquid chromatography with mass spectrometry detection and positive electrospray ionization. The separation of derivatized biogenic amines was achieved within 3.5 min on an Acquity® BEH C(18) column by elution with a linear gradient of acetonitrile/water/formic acid (0.1%). The assay was linear in the concentration range of 50-5000 pM for each amine (5.5-555 pg/ml for histamine and 6.25-625 pg/ml for tele-methylhistamine). For repeatability and precision determination, coefficients of variation (CVs) were less than 11.0% over the tested concentration ranges, within acceptance criteria. Thus, the developed method provides the rapid, easy, highly sensitive, and selective requirement to quantify these amines in human CSF. No significant difference was found in the mean ± standard error levels of these amines between a group of narcoleptic patients (histamine=392 ± 64 pM, tele-methylhistamine=2431 ± 461 pM, n=7) and of neurological control subjects (histamine=402 ± 72 pM, tele-methylhistamine=2209 ± 463 pM, n=32). Copyright © 2010 Elsevier Inc. All rights reserved.

  9. Sample collection and preparation of biofluids and extracts for gas chromatography-mass spectrometry.

    Science.gov (United States)

    Emwas, Abdul-Hamid M; Al-Talla, Zeyad A; Kharbatia, Najeh M

    2015-01-01

    To maximize the utility of gas chromatography-mass spectrometry (GC-MS) in metabonomics research, all stages of the experimental design should be standardized, including sample collection, storage, preparation, and sample separation. Moreover, the prerequisite for any GC-MS analysis is that a compound must be volatile and thermally stable if it is to be analyzed using this technique. Since many metabolites are nonvolatile and polar in nature, they are not readily amenable to analysis by GC-MS and require initial chemical derivatization of the polar functional groups in order to reduce the polarity and to increase the thermal stability and volatility of the analytes. In this chapter, an overview is presented of the optimum approach to sample collection, storage, and preparation for gas chromatography-mass spectrometry-based metabonomics with particular focus on urine samples as example of biofluids.

  10. Dependence of matrix effect on ionization polarity during LC-ESI-MS analysis of derivatized amino acids in some natural samples.

    Science.gov (United States)

    Oldekop, Maarja-Liisa; Rebane, Riin; Herodes, Koit

    2017-10-01

    Matrix effect, the influence of co-eluting components on the ionization efficiency of the analyte, affects the trueness and precision of the LC-ESI-MS analysis. Derivatization can reduce or eliminate matrix effect, for example, diethyl ethoxymethylenemalonate (DEEMM) derivatives have shown less matrix effect compared to other derivatives. Moreover, the use of negative ion mode can further reduce matrix effect. In order to investigate the combination of derivatization and different ionization modes, an LC-ESI-MS/MS method using alternating positive/negative ion mode was developed and validated. The analyses in positive and negative ion modes had comparable limit of quantitation values. The influence of ESI polarity on matrix effect was investigated during the analysis of 22 DEEMM-derivatized amino acids in herbal extracts and honeys. Sample dilution approach was used for the evaluation of the presence of matrix effect. Altogether, 4 honeys and 11 herbal extracts were analyzed, and the concentrations of 22 amino acids in the samples are presented. In the positive ion mode, matrix effect was observed for several amino acid derivatives and the matrix effect was stronger in honey samples compared to the herbal extracts. The negative ion mode was free from matrix effect, with only few exceptions in honeys (average relative standard deviation over all analytes and matrices was 8%; SD = 7%). The matrix effect was eliminated in the positive ion mode by sample dilution and agreement between concentrations from the two ion modes was achieved for most amino acids. In conclusion, it was shown that the combination of derivatization and negative ion mode can be a powerful tool for minimizing matrix effect in more complicated applications.

  11. A novel fast method for aqueous derivatization of THC, OH-THC and THC-COOH in human whole blood and urine samples for routine forensic analyses.

    Science.gov (United States)

    Stefanelli, Fabio; Pesci, Federica Giorgia; Giusiani, Mario; Chericoni, Silvio

    2018-04-01

    A novel aqueous in situ derivatization procedure with propyl chloroformate (PCF) for the simultaneous, quantitative analysis of Δ 9 -tetrahydrocannabinol (THC), 11-hydroxy-Δ 9 -tetrahydrocannabinol (OH-THC) and 11-nor-Δ 9 -tetrahydrocannabinol-carboxylic acid (THC-COOH) in human blood and urine is proposed. Unlike current methods based on the silylating agent [N,O-bis(trimethylsilyl)trifluoroacetamide] added in an anhydrous environment, this new proposed method allows the addition of the derivatizing agent (propyl chloroformate, PCF) directly to the deproteinized blood and recovery of the derivatives by liquid-liquid extraction. This novel method can be also used for hydrolyzed urine samples. It is faster than the traditional method involving a derivatization with trimethyloxonium tetrafluoroborate. The analytes are separated, detected and quantified by gas chromatography-mass spectrometry in selected ion monitoring mode (SIM). The method was validated in terms of selectivity, capacity of identification, limits of detection (LOD) and quantification (LOQ), carryover, linearity, intra-assay precision, inter-assay precision and accuracy. The LOD and LOQ in hydrolyzed urine were 0.5 and 1.3 ng/mL for THC and 1.2 and 2.6 ng/mL for THC-COOH, respectively. In blood, the LOD and LOQ were 0.2 and 0.5 ng/mL for THC, 0.2 and 0.6 ng/mL for OH-THC, and 0.9 and 2.4 ng/mL for THC-COOH, respectively. This method was applied to 35 urine samples and 50 blood samples resulting to be equivalent to the previously used ones with the advantage of a simpler method and faster sample processing time. We believe that this method will be a more convenient option for the routine analysis of cannabinoids in toxicological and forensic laboratories. Copyright © 2017 John Wiley & Sons, Ltd.

  12. A novel reversed-phase HPLC method for the determination of urinary creatinine by pre-column derivatization with ethyl chloroformate: comparative studies with the standard Jaffé and isotope-dilution mass spectrometric assays.

    Science.gov (United States)

    Leung, Elvis M K; Chan, Wan

    2014-02-01

    Creatinine is an important biomarker for renal function diagnosis and normalizing variations in urinary drug/metabolites concentration. Quantification of creatinine in biological fluids such as urine and plasma is important for clinical diagnosis as well as in biomonitoring programs and urinary metabolomics/metabonomics research. Current methods for creatinine determination either are nonselective or involve the use of expensive mass spectrometers. In this paper, a novel reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of creatinine of high hydrophilicity by pre-column derivatization with ethyl chloroformate is presented. N-Ethyloxycarbonylation of creatinine significantly enhanced the hydrophobicity of creatinine, facilitating its chromatographic retention as well as quantification by HPLC. Factors governing the derivatization reaction were studied and optimized. The developed method was validated and applied for the determination of creatinine in rat urine samples. Comparative studies with isotope-dilution mass spectrometric method revealed that the two methods do not yield systematic differences in creatinine concentrations, indicating the HPLC method is suitable for the determination of creatinine in urine samples.

  13. Determination of Parabens by Injection-Port Derivatization Coupled With Gas-Chromatography-Mass Spectrometry and Matrix Solid Phase Dispersion

    Science.gov (United States)

    Djatmika, Rosalina; Ding, Wang-Hsien; Sulistyarti, Hermin

    2018-01-01

    A rapid determination of four parabens preservatives (methyl paraben, ethyl paraben, propyl paraben, and butyl paraben) in marketed seafood is presented. Analytes were extracted and purified using matrix solid-phase dispersion (MSPD) method, followed by Injection port acylation gas chromatography-mass spectrometry (GC-MS) with acetic anhydride reagent. In this method, acylation of parabens was performed by acetic anhydride at GC injection-port generating reduction of the time-consuming sample-processing steps, and the amount of toxic reagents and solvents. The parameters affecting this method such as injection port temperature, purge-off time and acylation (acetic anhydride) volume were studied. In addition, the MSPD influence factors (including the amount of dispersant and clean-up co-sorbent, as well as the volume of elution solvent) were also investigated. After MSPD method and Injection port acylation applied, good linearity of analytes was achieved. The limits of quantitation (LOQs) were 0.2 to 1.0 ng/g (dry weight). Compared with offline derivatization commonly performed, injection port acylation employs a rapid, simple, low-cost and environmental-friendly derivatization process. The optimized method has been successfully applied for the analysis of parabens in four kind of marketed seafood. Preliminary results showed that the total concentrations of four selected parabens ranged from 16.7 to 44.7 ng/g (dry weight).

  14. Comparison of sampling methods for radiocarbon dating of carbonyls in air samples via accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Schindler, Matthias, E-mail: matthias.schindler@physik.uni-erlangen.de; Kretschmer, Wolfgang; Scharf, Andreas; Tschekalinskij, Alexander

    2016-05-15

    Three new methods to sample and prepare various carbonyl compounds for radiocarbon measurements were developed and tested. Two of these procedures utilized the Strecker synthetic method to form amino acids from carbonyl compounds with either sodium cyanide or trimethylsilyl cyanide. The third procedure used semicarbazide to form crystalline carbazones with the carbonyl compounds. The resulting amino acids and semicarbazones were then separated and purified using thin layer chromatography. The separated compounds were then combusted to CO{sub 2} and reduced to graphite to determine {sup 14}C content by accelerator mass spectrometry (AMS). All of these methods were also compared with the standard carbonyl compound sampling method wherein a compound is derivatized with 2,4-dinitrophenylhydrazine and then separated by high-performance liquid chromatography (HPLC).

  15. Comparison of sampling methods for radiocarbon dating of carbonyls in air samples via accelerator mass spectrometry

    Science.gov (United States)

    Schindler, Matthias; Kretschmer, Wolfgang; Scharf, Andreas; Tschekalinskij, Alexander

    2016-05-01

    Three new methods to sample and prepare various carbonyl compounds for radiocarbon measurements were developed and tested. Two of these procedures utilized the Strecker synthetic method to form amino acids from carbonyl compounds with either sodium cyanide or trimethylsilyl cyanide. The third procedure used semicarbazide to form crystalline carbazones with the carbonyl compounds. The resulting amino acids and semicarbazones were then separated and purified using thin layer chromatography. The separated compounds were then combusted to CO2 and reduced to graphite to determine 14C content by accelerator mass spectrometry (AMS). All of these methods were also compared with the standard carbonyl compound sampling method wherein a compound is derivatized with 2,4-dinitrophenylhydrazine and then separated by high-performance liquid chromatography (HPLC).

  16. A simultaneous derivatization of 3-monochloropropanediol and 1,3-dichloropropane with hexamethyldisilazane-trimethylsilyl trifluoromethanesulfonate at room temperature for efficient analysis of food sample analysis.

    Science.gov (United States)

    Lee, Bai Qin; Wan Mohamed Radzi, Che Wan Jasimah Bt; Khor, Sook Mei

    2016-02-05

    This paper reports the application of hexamethyldisilazane-trimethylsilyl trifluoromethanesulfonate (HMDS-TMSOTf) for the simultaneous silylation of 3-monochloro-1,2-propanediol (3-MCPD) and 1,3-dicholoropropanol (1,3-DCP) in solid and liquid food samples. 3-MCPD and 1,3-DCP are chloropropanols that have been established as Group 2B carcinogens in clinical testing. They can be found in heat-processed food, especially when an extended high-temperature treatment is required. However, the current AOAC detection method is time-consuming and expensive. Thus, HMDS-TMSOTf was used in this study to provide a safer, and cost-effective alternative to the HFBI method. Three important steps are involved in the quantification of 3-MCPD and 1,3-DCP: extraction, derivatization and quantification. The optimization of the derivatization process, which involved focusing on the catalyst volume, derivatization temperature, and derivatization time was performed based on the findings obtained from both the Box-Behnken modeling and a real experimental set up. With the optimized conditions, the newly developed method was used for actual food sample quantification and the results were compared with those obtained via the standard AOAC method. The developed method required less samples and reagents but it could be used to achieve lower limits of quantification (0.0043mgL(-1) for 1,3-DCP and 0.0011mgL(-1) for 3-MCPD) and detection (0.0028mgL(-1) for 1,3-DCP and 0.0008mgL(-1) for 3-MCPD). All the detected concentrations are below the maximum tolerable limit of 0.02mgL(-1). The percentage of recovery obtained from food sample analysis was between 83% and 96%. The new procedure was validated with the AOAC method and showed a comparable performance. The HMDS-TMSOTf derivatization strategy is capable of simultaneously derivatizing 1,3-DCP and 3-MCPD at room temperature, and it also serves as a rapid, sensitive, and accurate analytical method for food samples analysis. Copyright © 2015 Elsevier B

  17. Determination of eugenol in rat plasma by liquid chromatography-quadrupole ion trap mass spectrometry using a simple off-line dansyl chloride derivatization reaction to enhance signal intensity.

    Science.gov (United States)

    Beaudry, Francis; Guénette, Sarah Annie; Vachon, Pascal

    2006-11-01

    A rapid, selective and sensitive method was developed for the determination of eugenol concentration using an off-line dansyl chloride derivatization step to enhance signal intensity. The method consisted of a protein precipitation extraction followed by derivatization with dansyl chloride and analysis by full scan liquid chromatography electrospray quadrupole ion trap mass spectrometry (LC-ESI-QIT). The separation was achieved using a 100 x 2 mm C(8) analytical column combined with an isocratic mobile phase composed of 75:25 acetonitrile: 0.1% formic acid in water set at a flow rate of 0.25 mL/min. Signal intensity of the eugenol-dansyl chloride derivative was increased up to 100-fold as compared with the underivatized eugenol in positive electrospray mode. An analytical range of 100-20,000 ng/mL was used in the calibration curve of plasma and blood samples. The LOD observed was 0.5 pg injected on column. The novel method met all requirements of specificity, sensitivity, linearity, precision, accuracy and stability. In conclusion, a rapid and sensitive LC-ESI/MS/MS method using a derivatization agent was developed to enhance signal intensity of eugenol. Copyright (c) 2006 John Wiley & Sons, Ltd.

  18. Ferro-based derivatizing agents for LC/MS an LC/EC/MS

    NARCIS (Netherlands)

    Seiwert, Bettina

    2007-01-01

    Within this thesis, the development and application of ferrocene-based derivatizing agents for LC/MS and LC/EC/MS is presented. The advantages of derivatization by ferrocenes are the similtaneous introduction of a mass tag and an electroactive group, which make them ideally suited for LC/MS and

  19. Analysis of volatile thiols in alcoholic beverages by simultaneous derivatization/extraction and liquid chromatography-high resolution mass spectrometry.

    Science.gov (United States)

    Vichi, Stefania; Cortés-Francisco, Nuria; Caixach, Josep

    2015-05-15

    A simultaneous derivatization/extraction method followed by liquid chromatography-electrospray-high resolution mass spectrometry for the determination of volatile thiols in hydroalcoholic matrixes was optimized and used to identify and quantify volatile thiols in wine and beer samples. The method was evaluated in terms of sensitivity, precision, accuracy and selectivity. The experimental LOQs of eleven thiols tested ranged between 0.01 ng/L and 10 ng/L. Intra-day relative standard deviation (RSD) was in general lower than 10% and inter-day RSD ranged between 10% and 30%. Recovery in the model and real matrixes ranged from 45% to 129%. The method was then applied for the analysis of four white wines and six beers. Five out of the eleven reference thiols were identified and quantified in the samples analyzed. The non-target approach, carried out by monitoring the diagnostic ion at m/z 275.9922 [C13H10ONSe](+) in the fragmentation spectrum, allowed detecting, in the same samples, fourteen non-target thiols. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Gas chromatographic determination of 1,1-dimethylhydrazine in water samples by solid-phase microextraction with derivatization

    Directory of Open Access Journals (Sweden)

    Madi Abilev

    2014-10-01

    Full Text Available 1,1-Dimethylhydrazine (1,1-DMH used as a rocket fuel component is highly reactive and unstable compound. It greatly complicates its accurate and express determination in environmental samples. Goal of this work was to develop a method for its express determination in water samples based on solid-phase microextraction with preliminary derivatization. Acetone was selected as reagent for derivatization because during its reaction with 1,1-DMH, volatile and hydrophobic acetone dimethylhydrazone (ADMH was formed. It was established that fiber based on 100-micron polydimethylsiloxane provides the most efficient extraction of ADMH from water at extraction time 2 min. Optimal concentration of acetone was 30 mg/mL. The minimum time for reaction of 1,1-DMH with acetone is 10 minutes. Addition of acids and alkali reduced ADMH response that may be caused by degradation of 1,1-DMH and reduction of derivatization rate. Addition of salt allowed to increase the response of ADMH however made impossible the quantitative determination of 1,1-DMH. Dependence of ADMH response on the concentration of 1,1-DMH at optimized parameters is linear in the concentrations range of 0.1-100 mg/L and can be used for quantitative determination of 1,1-DMH in water. Detection limit of the developed method is 0.02 mg/L. Reproducibility index of the method in the whole range of concentrations did not exceed 7%, accuracy index - 15%. Developed method is simple, inexpensive, accurate, automated and can be recommended for implementation in laboratories conducting environmental monitoring in areas of rocket-carriers fall.

  1. Peptides derivatized with bicyclic quaternary ammonium ionization tags. Sequencing via tandem mass spectrometry.

    Science.gov (United States)

    Setner, Bartosz; Rudowska, Magdalena; Klem, Ewelina; Cebrat, Marek; Szewczuk, Zbigniew

    2014-10-01

    Improving the sensitivity of detection and fragmentation of peptides to provide reliable sequencing of peptides is an important goal of mass spectrometric analysis. Peptides derivatized by bicyclic quaternary ammonium ionization tags: 1-azabicyclo[2.2.2]octane (ABCO) or 1,4-diazabicyclo[2.2.2]octane (DABCO), are characterized by an increased detection sensitivity in electrospray ionization mass spectrometry (ESI-MS) and longer retention times on the reverse-phase (RP) chromatography columns. The improvement of the detection limit was observed even for peptides dissolved in 10 mM NaCl. Collision-induced dissociation tandem mass spectrometry of quaternary ammonium salts derivatives of peptides showed dominant a- and b-type ions, allowing facile sequencing of peptides. The bicyclic ionization tags are stable in collision-induced dissociation experiments, and the resulted fragmentation pattern is not significantly influenced by either acidic or basic amino acid residues in the peptide sequence. Obtained results indicate the general usefulness of the bicyclic quaternary ammonium ionization tags for ESI-MS/MS sequencing of peptides. Copyright © 2014 John Wiley & Sons, Ltd.

  2. Derivatized graphitic nanofibres (GNF) as a new support material for mass spectrometric analysis of peptides and proteins.

    Science.gov (United States)

    Greiderer, Andreas; Rainer, Matthias; Najam-ul-Haq, Muhammad; Vallant, Rainer M; Huck, Christian W; Bonn, Günther K

    2009-07-01

    Graphitic nanofibres (GNFs), 100-200 nm in diameter and 5-20 microm in length have been modified in order to yield different affinities (Cu2+ and Fe3+ loaded immobilized metal affinity chromatography (IMAC) as well as cation and anion exchange materials) for the extraction of a range of biomolecules by their inherited hydrophobicity and the hydrophilic chemical functionalities, obtained by derivatization. Modified GNFs have for the first time been employed as carrier materials for protein profiling in material-enhanced laser desorption/ionization (MELDI) for the enrichment and screening of biofluids. For that purpose, the derivatized GNF materials have comprehensively been characterized regarding surface area, structural changes during derivatization, IMAC, as well as ion exchange and protein-loading capacity and recovery. GNF derivatives revealed high protein-binding capacity (2,000 microg ml(-1) for insulin) and ideal sensitivities, resulting in a detection limit of 50 fmol microl(-1) (for insulin), which is crucial for the detection of low abundant species in biological samples. Compared to other MELDI carrier materials, sensitivity was enhanced on GNF derivatives, which might be ascribed to the fact that GNFs support desorption and ionization mechanisms and by absorbing laser energy in addition to matrix.

  3. Liquid chromatographic determination of microcystins in water samples following pre-column excimer fluorescence derivatization with 4-(1-pyrene)butanoic acid hydrazide.

    Science.gov (United States)

    Hayama, Tadashi; Katoh, Kenji; Aoki, Takayoshi; Itoyama, Miki; Todoroki, Kenichiro; Yoshida, Hideyuki; Yamaguchi, Masatoshi; Nohta, Hitoshi

    2012-11-28

    A method to measure the concentrations of microcystins (MCs) in water samples has been developed by incorporating pre-column fluorescence derivatization and liquid chromatography (LC). A solid-phase extraction for pretreatment was used to extract the MCs in water samples. The MCs were derivatized with excimer-forming 4-(1-pyrene)butanoic acid hydrazide (PBH). The MCs could then be detected by fluorescence after separation with a pentafluorophenyl (PFP)-modified superficially porous (core shell) particle LC column. The derivatization reactions of MCs with PBH proceeded easily in the presence of 4,6-dimethoxy-1,3,5-triazin-2-yl-4-methylmorpholinium (DMT-MM) as a condensation reagent, and the resulting derivatives could be easily separated on the PFP column. The derivatives were selectively detected at excimer fluorescence wavelengths (440-540 nm). The instrument detection limit and the instrument quantification limit of the MCs standards were 0.4-1.2 μg L(-1) and 1.4-3.9 μg L(-1), respectively. The method was validated at 0.1 and 1.0 μg L(-1) levels in tap and pond water samples, and the recovery of MCs was between 67 and 101% with a relative standard deviation of 11%. The proposed method can be used to quantify trace amounts of MCs in water samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Determination of protein carbonyls in plasma, cell extracts, tissue homogenates, isolated proteins: Focus on sample preparation and derivatization conditions.

    Science.gov (United States)

    Weber, Daniela; Davies, Michael J; Grune, Tilman

    2015-08-01

    Protein oxidation is involved in regulatory physiological events as well as in damage to tissues and is thought to play a key role in the pathophysiology of diseases and in the aging process. Protein-bound carbonyls represent a marker of global protein oxidation, as they are generated by multiple different reactive oxygen species in blood, tissues and cells. Sample preparation and stabilization are key steps in the accurate quantification of oxidation-related products and examination of physiological/pathological processes. This review therefore focuses on the sample preparation processes used in the most relevant methods to detect protein carbonyls after derivatization with 2,4-dinitrophenylhydrazine with an emphasis on measurement in plasma, cells, organ homogenates, isolated proteins and organelles. Sample preparation, derivatization conditions and protein handling are presented for the spectrophotometric and HPLC method as well as for immunoblotting and ELISA. An extensive overview covering these methods in previously published articles is given for researchers who plan to measure protein carbonyls in different samples. © 2015 Published by Elsevier Ltd.

  5. A rapid novel derivatization of amphetamine and methamphetamine using 2,2,2-trichloroethyl chloroformate for gas chromatography electron ionization and chemical ionization mass spectrometric analysis.

    Science.gov (United States)

    Dasgupta, A; Spies, J

    1998-05-01

    Amphetamine and methamphetamine are commonly abused central nervous system stimulants. We describe a rapid new derivatization of amphetamine and methamphetamine using 2,2,2-trichloroethyl chloroformate for gas chromatography-mass spectrometric analysis. Amphetamine and methamphetamine, along with N-propyl amphetamine (internal standard), were extracted from urine using 1-chlorobutane. The derivatization with 2,2,2-trichloroethyl chloroformate can be achieved at room temperature in 10 minutes. The electron ionization mass spectrum of amphetamine 2,2,2-trichloroethyl carbamate showed two weak molecular ions at m/z 309 and 311, but showed diagnostic strong peaks at m/z 218, 220, and 222. In contrast, chemical ionization of the mass spectrum of amphetamine 2,2,2-trichloroethyl carbamate showed strong (M + 1) ions at m/z 310 and 312 and other strong diagnostic peaks at m/z 274 and 276. The major advantages of this derivative are the presence of a diagnostic cluster of peaks due to the isotopic effect of three chlorine atoms (isotopes 35 and 37) in the derivatized molecule and the relative ease of its preparation. We also observed strong molecular ions for derivatized methamphetamine in the chemical ionization mass spectrum, but the molecular ions were very weak in the electron ionization mass spectrum. We used the scan mode of mass spectrometry in all analyses. When using a urine standard containing 1,000 ng/mL of amphetamine (a 7.4-micromol/L concentration) and methamphetamine (a 6.7-micromol/L concentration), the within-run precisions were 4.8% for amphetamine and 3.6% for methamphetamine. The corresponding between-run precisions were 5.3% for amphetamine and 6.7% for methamphetamine. The assay was linear for amphetamine and methamphetamine concentrations of 250 to 5,000 ng/mL (amphetamine, 1.9-37.0 micromol/L; methamphetamine, 1.7-33.6 micromol/L). The detection limit was 100 ng/mL (amphetamine, 0.74 micromol/L; methamphetamine, 0.67 micromol/L) using the scan mode

  6. Profiling and relative quantification of phosphatidylethanolamine based on acetone stable isotope derivatization

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiang [Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture (China); Hubei Key Laboratory of Lipid Chemistry and Nutrition (China); Wei, Fang, E-mail: willasa@163.com [Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture (China); Hubei Key Laboratory of Lipid Chemistry and Nutrition (China); Xu, Ji-qu; Lv, Xin; Dong, Xu-yan [Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture (China); Hubei Key Laboratory of Lipid Chemistry and Nutrition (China); Han, Xianlin [Center for Metabolic Origins of Disease, Sanford Burnham Prebys Medical Discovery Institute, Orlando, FL 32827 (United States); College of Basic Medical Sciences, Zhejiang Chinese Medical University, 548 Bingwen Road, Hangzhou, Zhejiang 310053 (China); Quek, Siew-young [School of Chemical Science, The University of Auckland, Auckland 1142 (New Zealand); Huang, Feng-hong [Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture (China); Hubei Key Laboratory of Lipid Chemistry and Nutrition (China); Chen, Hong, E-mail: chenhong@oilcrops.cn [Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture (China); Hubei Key Laboratory of Lipid Chemistry and Nutrition (China)

    2016-01-01

    Phosphatidylethanolamine (PE) is considered to be one of the pivotal lipids for normal cellular function as well as disease initiation and progression. In this study, a simple, efficient, reliable, and inexpensive method for the qualitative analysis and relative quantification of PE, based on acetone stable isotope derivatization combined with double neutral loss scan-shotgun electrospray ionization tandem-quadrupole mass spectrometry analysis (ASID-DNLS-Shotgun ESI-MS/MS), was developed. The ASID method led to alkylation of the primary amino groups of PE with an isopropyl moiety. The use of acetone (d{sub 0}-acetone) and deuterium-labeled acetone (d{sub 6}-acetone) introduced a 6 Da mass shift that was ideally suited for relative quantitative analysis, and enhanced sensitivity for mass analysis. The DNLS model was introduced to simultaneously analyze the differential derivatized PEs by shotgun ESI-MS/MS with high selectivity and accuracy. The reaction specificity, labeling efficiency, and linearity of the ASID method were thoroughly evaluated in this study. Its excellent applicability was validated by qualitative and relative quantitative analysis of PE species presented in liver samples from rats fed different diets. Using the ASID-DNLS-Shotgun ESI-MS/MS method, 45 PE species from rat livers have been identified and quantified in an efficient manner. The level of total PEs tended to decrease in the livers of rats on high fat diets compared with controls. The levels of PE 32:1, 34:3, 34:2, 36:3, 36:2, 42:10, plasmalogen PE 36:1 and lyso PE 22:6 were significantly reduced, while levels of PE 36:1 and lyso PE 16:0 increased. - Highlights: • A novel isotope reagent acetone was explored for the derivatization of PEs. • The labeling reaction was carried out under mild conditions with high specificity. • Enhanced detection sensitivity of PEs was achieved after derivatization. • The ASID-DNLS-Shotgun MS/MS method was used to relative quantification of PEs.

  7. Determination of 1,3-dichloro-2-propanol and 3-chloro-1,2-propandiol in soy sauce by headspace derivatization solid-phase microextraction combined with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Lee, Maw-Rong; Chiu, Tzu-Chun; Dou, Jianpeng

    2007-05-22

    This study proposes a method for identifying 1,3-dichloro-2-propanol and 3-chloro-1,2-propandiol in aqueous matrices by using headspace on-fiber derivatization following solid-phase microextraction combined with gas chromatography-mass spectrometry. The optimized SPME experimental procedures for extracting 1,3-dichloro-2-propanol and 3-chloro-1,2-propandiol in aqueous solutions involved a 85 microm polyacrylate-coated fiber at pH 6, a sodium chloride concentration of 0.36 g mL(-1), extraction at 50 degrees C for 15 min and desorption of analytes at 260 degrees C for 3 min. Headspace derivatization was conducted in a laboratory-made design with N-methyl-N-(trimethylsilyl)-trifluoroacetamide vapor following solid-phase microextraction by using 3 microL N-methyl-N-(trimethylsilyl)-trifluoroacetamide at an oil bath temperature of 230 degrees C for 40 s. This method had good repeatability (R.S.D.s or = 0.9972) for ultrapure water and soy sauce samples that were spiked with two analytes. Detection limits were obtained at the ng mL(-1). The result demonstrated that headspace on-fiber derivatization following solid-phase microextraction was a simple, fast and accurate technique for identifying trace 1,3-dichloro-2-propanol and 3-chloro-1,2-propandiol in soy sauce.

  8. Development of a polydimethylsiloxane-thymol/nitroprusside composite based sensor involving thymol derivatization for ammonium monitoring in water samples.

    Science.gov (United States)

    Prieto-Blanco, M C; Jornet-Martínez, N; Moliner-Martínez, Y; Molins-Legua, C; Herráez-Hernández, R; Verdú Andrés, J; Campins-Falcó, P

    2015-01-15

    This report describes a polydimethylsiloxane (PDMS)-thymol/nitroprusside delivery composite sensor for direct monitoring of ammonium in environmental water samples. The sensor is based on a PDMS support that contains the Berthelot's reaction reagents. To prepare the PDMS-thymol/nitroprusside composite discs, thymol and nitroprusside have been encapsulated in the PDMS matrix, forming a reagent release support which significantly simplifies the analytical measurements, since it avoids the need to prepare derivatizing reagents and sample handling is reduced to the sampling step. When, the PDMS-thymol/nitroprusside composite was introduced in water samples spontaneous release of the chromophore and catalyst was produced, and the derivatization reaction took place to form the indothymol blue. Thus, qualitative analysis of NH4(+) could be carried out by visual inspection, but also, it can be quantified by measuring the absorbance at 690 nm. These portable devices provided good sensitivity (LODdetection of ammonium. The PDMS-NH4(+) sensor has been successfully applied to determine ammonium in water samples and in the aqueous extracts of particulate matter PM10 samples. Moreover, the reliability of the method for qualitative analysis has been demonstrated. Finally, the advantages of the PDMS-NH4(+) sensor have been examined by comparing some analytical and complementary characteristics with the properties of well-established ammonium determination methods. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Determination of desipramine in biological samples using liquid-liquid-liquid microextraction combined with in-syringe derivatization, gas chromatography, and nitrogen/phosphorus detection.

    Science.gov (United States)

    Saraji, Mohammad; Mehrafza, Narges; Bidgoli, Ali Akbar Hajialiakbari; Jafari, Mohammad Taghi

    2012-10-01

    A method was established for the determination of desipramine in biological samples using liquid-liquid-liquid microextraction followed by in-syringe derivatization and gas chromatography-nitrogen phosphorus detection. The extraction method was based on the use of two immiscible organic solvents. n-Dodecane was impregnated in the pores of the hollow fiber and methanol was placed inside the lumen of the fiber as the acceptor phase. Acetic anhydride was used as the reagent for the derivatization of the analyte inside the syringe barrel. Parameters that affect the extraction efficiency (composition of donor and acceptor phase, ionic strength, sample temperature, and extraction time) as well as derivatization efficiency (amount of acetic anhydride and reaction time and temperature) were investigated. The limit of detection was 0.02 μg/L with intra and interday RSDs of 2.6 and 7.7%, respectively. The linearity of the method was in the range of 0.2-20 μg/L (r(2) = 0.9986). The method was successfully applied to determine desipramine in human plasma and urine. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Quantification of piperazine phosphate in human plasma by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry employing precolumn derivatization with dansyl chloride.

    Science.gov (United States)

    Lin, Hui; Tian, Yuan; Zhang, Zunjian; Wu, Lili; Chen, Yun

    2010-04-01

    This paper describes a novel method that combines dansyl chloride (DNS-CL) derivatization with high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) for the sensitive and selective determination of piperazine phosphate in human plasma. After addition of ondansetron hydrochloride as internal standard (IS), piperazine phosphate was derivatized and then extracted with ethyl acetate. After being evaporated and reconstituted, the sample was analyzed using LC-ESI/MS/MS. Separation was achieved using an Agilent ZORBAX SB-C(18) (150 mm x 2.1 mm I.D., 3.5 microm) column and isocratic elution with 10 mM ammonium acetate solution (pH 3.0)-methanol (50: 50, v/v). Detection was performed on a triple-quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 320-->171 for DNS-CL-piperazine phosphate and m/z 294-->170 for the IS. The method was fully validated for its selectivity, sensitivity, linearity, precision, accuracy, recovery, matrix effect and stability. The coefficient (r) of piperazine phosphate with a linear range of 0.1-15 microg mL(-1) was 0.9974-0.9995. The limit of detection and lower limit of quantification in human plasma were 0.01 and 0.1 microg mL(-1), respectively. The validated LC-ESI/MS/MS method has been successfully applied to a bioequivalence study of piperazine phosphate trochiscus in Chinese healthy male volunteers. 2010 Elsevier B.V. All rights reserved.

  11. Ultrasensitive determination of formaldehyde in environmental waters and food samples after derivatization and using silver nanoparticle assisted SERS

    International Nuclear Information System (INIS)

    Ma, Pinyi; Wang, Di; Yang, Qingqing; Song, Daqian; Wang, Xinghua; Liang, Fanghui; Ding, Yaying; Yu, Yong; Gao, Dejiang

    2015-01-01

    A selective and ultrasensitive surface-enhanced Raman spectroscopy (SERS) method was developed for the determination of formaldehyde (HCHO) in environmental waters and food samples. It is based on derivatization of HCHO with 4-amino-5-hydrazino-3-mercapto-1,2,4-triazole (AHMT) with HCHO. One of the products of the derivative reaction, 6-mercapto-5-triazolo[4,3-b]-s-tetrazine (MTT), can be quantified by SERS at 832 cm −1 using silver nanoparticles (AgNPs) as substrates. The incubation time for derivatization, the volume of reagents and the mixing times were optimized. The peak areas of the SERS are linearly related to the concentration of HCHO in the 1 − 1,000 μg L −1 range, the limit of detection is 0.15 μg L −1 , and the limit of quantification is 0.45 μg L −1 . Recoveries obtained by analyzing two spiked samples of environmental water and two spiked food samples were in the range between 91.0 and 108.7 %. There is no significant difference between the results obtained by the present method and the liquid chromatographic method (Chinese industrial standard method, SN/T 1547-2011). (author)

  12. Sequential derivatization of polar organic compounds in cloud water using O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride, N,O-bis(trimethylsilyl)trifluoroacetamide, and gas-chromatography/mass spectrometry analysis.

    Science.gov (United States)

    Sagona, Jessica A; Dukett, James E; Hawley, Harmonie A; Mazurek, Monica A

    2014-10-03

    Cloud water samples from Whiteface Mountain, NY were used to develop a combined sampling and gas chromatography-mass spectrometric (GCMS) protocol for evaluating the complex mixture of highly polar organic compounds (HPOC) present in this atmospheric medium. Specific HPOC of interest were mono- and di keto-acids which are thought to originate from photochemical reactions of volatile unsaturated hydrocarbons from biogenic and manmade emissions and be a major fraction of atmospheric carbon. To measure HPOC mixtures and the individual keto-acids in cloud water, samples first must be derivatized for clean elution and measurement, and second, have low overall background of the target species as validated by GCMS analysis of field and laboratory blanks. Here, we discuss a dual derivatization method with PFBHA and BSTFA which targets only organic compounds that contain functional groups reacting with both reagents. The method also reduced potential contamination by minimizing the amount of sample processing from the field through the GCMS analysis steps. Once derivatized only gas chromatographic separation and selected ion monitoring (SIM) are needed to identify and quantify the polar organic compounds of interest. Concentrations of the detected total keto-acids in individual cloud water samples ranged from 27.8 to 329.3ngmL(-1) (ppb). Method detection limits for the individual HPOC ranged from 0.17 to 4.99ngmL(-1) and the quantification limits for the compounds ranged from 0.57 to 16.64ngmL(-1). The keto-acids were compared to the total organic carbon (TOC) results for the cloud water samples with concentrations of 0.607-3.350mgL(-1) (ppm). GCMS analysis of all samples and blanks indicated good control of the entire collection and analysis steps. Selected ion monitoring by GCMS of target keto-acids was essential for screening the complex organic carbon mixtures present at low ppb levels in cloud water. It was critical for ensuring high levels of quality assurance and

  13. 2-Naphthalenthiol derivatization followed by dispersive liquid-liquid microextraction as an efficient and sensitive method for determination of acrylamide in bread and biscuit samples using high-performance liquid chromatography.

    Science.gov (United States)

    Faraji, Mohammad; Hamdamali, Mohammadrezza; Aryanasab, Fezzeh; Shabanian, Meisam

    2018-07-13

    In this research, an ultrasonic-assisted extraction followed by 2-naphthalenthiol derivatization and dispersive liquid-liquid microextraction of acrylamide (AA) was developed as simple and sensitive sample preparation method for AA in bread and biscuit samples using high performance liquid chromatography. Influence of derivatization and microextraction parameters were evaluated and optimized. Results showed that the derivatization of AA leads to improve its hydrophobicity and chromatographic behavior. Under optimum conditions of derivatization and microextraction, the method yielded a linear calibration curve ranging from 10 to 1000 μg L -1 with a determination coefficient (R 2 ) of 0.9987. Limit of detection (LOD) and limit of quantification (LOQ) were 3.0 and 9.0 μg L -1 , respectively. Intra-day (n = 6) and inter-day (n = 3) precisions based on relative standard deviation percent (RSD%) for extraction and determination of AA at 50 and 500 μg L -1 levels were less than 9.0%. Finally, the performance of proposed method was investigated for determination of AA in some bread and biscuit samples, and satisfactory results were obtained (relative recovery ≥ 90%). Copyright © 2018. Published by Elsevier B.V.

  14. Indirect enantioseparation of fluoxetine in mouse serum by derivatization with 1R-(-)-menthyl chloroformate followed by ultra high performance liquid chromatography and quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Zhao, Jing; Jin, Yan; Shin, Yujin; Jeong, Kyung Min; Lee, Jeongmi

    2016-03-01

    Here we describe a simple and sensitive analytical method for the enantioselective quantification of fluoxetine in mouse serum using ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry. The sample preparation method included a simple deproteinization with acetonitrile in 50 μL of serum, followed by derivatization of the extracts in 50 μL of 2 mM 1R-(-)-menthyl chloroformate at 45ºC for 55 min. These conditions were statistically optimized through response surface methodology using a central composite design. Under the optimized conditions, neither racemization nor kinetic resolution occurred. The derivatized diastereomers were readily resolved on a conventional sub-2 μm C18 column under a simple gradient elution of aqueous methanol containing 0.1% formic acid. The established method was validated and found to be linear, precise, and accurate over the concentration range of 5.0-1000.0 ng/mL for both R and S enantiomers (r(2) > 0.993). Stability tests of the prepared samples at three different concentration levels showed that the R- and S-fluoxetine derivatives were relatively stable for 48 h. No significant matrix effects were observed. Last, the developed method was successfully used for enantiomeric analysis of real serum samples collected at a number of time points from mice administered with racemic fluoxetine. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. A novel liquid chromatography-tandem mass spectrometry method for determination of menadione in human plasma after derivatization with 3-mercaptopropionic acid.

    Science.gov (United States)

    Liu, Ruijuan; Wang, Mengmeng; Ding, Li

    2014-10-01

    Menadione (VK3), an essential fat-soluble naphthoquinone, takes very important physiological and pathological roles, but its detection and quantification is challenging. Herein, a new method was developed for quantification of VK3 in human plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS) after derivatization with 3-mercaptopropionic acid via Michael addition reaction. The derivative had been identified by the mass spectra and the derivatization conditions were optimized by considering different parameters. The method was demonstrated with high sensitivity and a low limit of quantification of 0.03 ng mL(-1) for VK3, which is about 33-fold better than that for the direct analysis of the underivatized compound. The method also had good precision and reproducibility. It was applied in the determination of basal VK3 in human plasma and a clinical pharmacokinetic study of menadiol sodium diphosphate. Furthermore, the method for the quantification of VK3 using LC-MS/MS was reported in this paper for the first time, and it will provide an important strategy for the further research on VK3 and menadione analogs. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Gas chromatography--inductively coupled plasma--time-of-flight mass spectrometry for the speciation analysis of organolead compounds in environmental water samples.

    Science.gov (United States)

    Heisterkamp, M; Adams, F C

    2001-07-01

    The application of inductively coupled plasma--time-of-flight mass spectrometry for the speciation analysis of organolead compounds in environmental waters is described. Construction of the transfer line was achieved by means of a relatively simple and rapid coupling procedure. Derivatization of the ionic lead species was achieved by in-situ propylation with sodium tetrapropylborate; simultaneous extraction of the derivatized compounds in hexane was followed by separation and detection by capillary gas chromatography hyphenated to inductively coupled plasma-time-of-flight mass spectrometry. Detection limits for the different organolead species ranged from 10 to 15 fg (as Pb), corresponding to procedural detection limits between 50 and 75 ng L(-1), on the basis of a 50 mL snow sample, extraction with 200 microL hexane, and subsequent injection of 1 microL of the organic extract on to the column. The accuracy of the system was confirmed by additional analysis of the water samples by capillary gas chromatography coupled with microwave-induced plasma-atomic-emission spectrometry and the analysis of a standard reference material CRM 605 (road dust) with a certified content of trimethyllead.

  17. Expanded metabolite coverage of Saccharomyces cerevisiae extract through improved chloroform/methanol extraction and tert-butyldimethylsilyl derivatization

    DEFF Research Database (Denmark)

    Khoomrung, Sakda; Martinez Ruiz, José Luis; Tippmann, Stefan

    2015-01-01

    and non-polar metabolites were derivatized using tert-butyldimethylsilyl (t-BDMS) dissolved in acetonitrile. Using microwave treatment of the samples, the derivatization process could be completed within 2 h (from >20 h of the conventional method), providing fully derivatized metabolites that contain...

  18. Elimination of N,O-bis(trimethylsilyl)trifluoroacetamide interference by base treatment in derivatization gas chromatography mass spectrometry determination of parts per billion of alcohols in a food additive.

    Science.gov (United States)

    Zhu, Koudi; Gu, Binghe; Kerry, Michael; Mintert, Markus; Luong, Jim; Pursch, Matthias

    2017-03-24

    A novel base treatment followed by liquid-liquid extraction was developed to remove the interference of excess derivatization reagent BSTFA [N,O-Bis(trimethylsilyl)trifluoroacetamide] and its byproducts for trace determination of 1-chloro-2-propanol and 2-chloro-1-propanol in a food additive. The corresponding trimethylsilyl derivatives were analyzed by gas chromatography mass spectrometry (GC/MS) detection in selective ion monitoring mode. Due to a large volume splitless injection needed for achieving the required sensitivity, excess BSTFA in the derivatization sample solution interfered with the trimethylsilyl derivatives of the analytes of interest, making their quantitation not attainable. Efforts were made to decompose BSTFA while keeping the trimethylsilyl derivatives intact. Water or aqueous sulfuric acid treatment converted BSTFA into mainly N-trimethylsilyltrifluoroacetamide, which partitions between aqueous and organic layers. In contrast, aqueous sodium hydroxide decomposed BSTFA into trifluoroacetic acid, which went entirely into the aqueous layer. No BSTFA or its byproduct N-trimethylsilyltrifluoroacetamide or trifluroacetamide was found in the organic layer where the derivatized alcohols existed, which in turn completely eliminated their interference, enabling accurate and precise determination of parts per billion of the short-chain alcohols in the food additive. Contrary to the conventional wisdom that a trimethylsilyl derivative is susceptible to hydrolysis, the derivatized short-chain alcohols were found stable even in the presence of 0.17N aqueous sodium hydroxide as the improved GC/MS method was validated successfully, with a satisfactory linearity response in the concentration range of 10-400ng/g (regression coefficient greater than 0.999), good method precision (<4%), good recovery (90-98%), and excellent limit of detection (3ng/g) and limit of quantitation (10ng/g). Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Sensitive Determination of Onco-metabolites of D- and L-2-hydroxyglutarate Enantiomers by Chiral Derivatization Combined with Liquid Chromatography/Mass Spectrometry Analysis

    Science.gov (United States)

    Cheng, Qing-Yun; Xiong, Jun; Huang, Wei; Ma, Qin; Ci, Weimin; Feng, Yu-Qi; Yuan, Bi-Feng

    2015-01-01

    2-hydroxyglutarate (2HG) is a potent competitor of α-ketoglutarate (α-KG) and can inhibit multiple α-KG dependent dioxygenases that function on the epigenetic modifications. The accumulation of 2HG contributes to elevated risk of malignant tumors. 2HG carries an asymmetric carbon atom in its carbon backbone and differentiation between D-2-hydroxyglutarate (D-2HG) and L-2-hydroxyglutarate (L-2HG) is crucially important for accurate diagnosis of 2HG related diseases. Here we developed a strategy by chiral derivatization combined with liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis for highly sensitive determination of D-2HG and L-2HG enantiomers. N-(p-toluenesulfonyl)-L-phenylalanyl chloride (TSPC) was used to derivatize 2HG. The formed diastereomers by TSPC labeling can efficiently improve the chromatographic separation of D-2HG and L-2HG. And derivatization by TSPC could also markedly increase the detection sensitivities by 291 and 346 folds for D-2HG and L-2HG, respectively. Using the developed method, we measured the contents of D-2HG and L-2HG in clear cell renal cell carcinoma (ccRCC) tissues. We observed 12.9 and 29.8 folds increase of D-2HG and L-2HG, respectively, in human ccRCC tissues compared to adjacent normal tissues. The developed chiral derivatization combined with LC-ESI-MS/MS analysis offers sensitive determination of D-2HG and L-2HG enantiomers, which benefits the precise diagnosis of 2HG related metabolic diseases. PMID:26458332

  20. Highly specific purification of N-glycans using phosphate-based derivatization as an affinity tag in combination with Ti{sup 4+}-SPE enrichment for mass spectrometric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Ying [Shanghai Cancer Center and Institutes of Biomedical Sciences, Fudan University, Shanghai 200032 (China); Key Laboratory of Glycoconjugates Research Ministry of Public Health, Fudan University, Shanghai 200032 (China); Peng, Ye; Bin, Zhichao [Department of Chemistry, Fudan University, Shanghai 200032 (China); Wang, Huijie [Shanghai Cancer Center and Institutes of Biomedical Sciences, Fudan University, Shanghai 200032 (China); Lu, Haojie, E-mail: luhaojie@fudan.edu.cn [Shanghai Cancer Center and Institutes of Biomedical Sciences, Fudan University, Shanghai 200032 (China); Department of Chemistry, Fudan University, Shanghai 200032 (China); Key Laboratory of Glycoconjugates Research Ministry of Public Health, Fudan University, Shanghai 200032 (China)

    2016-08-31

    N-linked protein glycosylation is involved in regulation of a wide variety of cellular processes and associated with numerous diseases. Highly specific identification of N-glycome remains a challenge while its biological significance is acknowledged. The relatively low abundance of glycan in complex biological mixtures, lack of basic sites for protonation, and suppression by other highly abundant proteins/peptides lead to the particularly poor detection sensitivity of N-glycans in the MS analysis. Therefore, the highly specific purification procedure becomes a crucial step prior to MS analysis of the N-glycome. Herein, a novel N-glycans enrichment approach based on phosphate derivatization combined with Ti{sup 4+}-SPE (solid phase extraction) was developed. Briefly, in this strategy, N-glycans were chemically labeled with a phospho-group at their reducing ends, such that the Ti{sup 4+}-SPE microspheres were able to capture the phospho-containing glycans. The enrichment method was developed and optimized using model oligosaccharides (maltoheptaose DP7 and sialylated glycan A1) and also glycans from a standard glycoprotein (asialofetuin, ASF). This method experimentally showed high derivatization efficiency (almost 100%), excellent selectivity (analyzing DP7 in the digests of bovine serum albumin at a mass ratio of 1:100), high enriching recovery (90%), good reproducibility (CV<15%) as well as high sensitivity (LOD at fmol level). At last, the proposed method was successfully applied in the profiling of N-glycome in human serum, in which a total of 31 N-glycan masses were identified. - Graphical abstract: A selective enrichment method for the N-glycome is reported. N-glycans were chemically labeled with a phosphate derivatization reagent (AMS), then the phospho-containing glycans were enriched using Ti{sup 4+}-microspheres. - Highlights: • A highly specific N-glycans purification method based on phosphate derivatization combined with Ti{sup 4+}-SPE was developed

  1. Sensitive determination of thiols in wine samples by a stable isotope-coded derivatization reagent d0/d4-acridone-10-ethyl-N-maleimide coupled with high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry analysis.

    Science.gov (United States)

    Lv, Zhengxian; You, Jinmao; Lu, Shuaimin; Sun, Weidi; Ji, Zhongyin; Sun, Zhiwei; Song, Cuihua; Chen, Guang; Li, Guoliang; Hu, Na; Zhou, Wu; Suo, Yourui

    2017-03-31

    As the key aroma compounds, varietal thiols are the crucial odorants responsible for the flavor of wines. Quantitative analysis of thiols can provide crucial information for the aroma profiles of different wine styles. In this study, a rapid and sensitive method for the simultaneous determination of six thiols in wine using d 0 /d 4 -acridone-10-ethyl-N-maleimide (d 0 /d 4 -AENM) as stable isotope-coded derivatization reagent (SICD) by high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) has been developed. Quantification of thiols was performed by using d 4 -AENM labeled thiols as the internal standards (IS), followed by stable isotope dilution HPLC-ESI-MS/MS analysis. The AENM derivatization combined with multiple reactions monitoring (MRM) not only allowed trace analysis of thiols due to the extremely high sensitivity, but also efficiently corrected the matrix effects during HPLC-MS/MS and the fluctuation in MS/MS signal intensity due to instrument. The obtained internal standard calibration curves for six thiols were linear over the range of 25-10,000pmol/L (R 2 ≥0.9961). Detection limits (LODs) for most of analytes were below 6.3pmol/L. The proposed method was successfully applied for the simultaneous determination of six kinds of thiols in wine samples with precisions ≤3.5% and recoveries ≥78.1%. In conclusion, the developed method is expected to be a promising tool for detection of trace thiols in wine and also in other complex matrix. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Dried blood spot on-card derivatization: an alternative form of sample handling to overcome the instability of thiorphan in biological matrix.

    Science.gov (United States)

    Mess, Jean-Nicholas; Taillon, Marie-Pierre; Côté, Cynthia; Garofolo, Fabio

    2012-12-01

    Thiorphan, the active metabolite of racecadotril, can undergo oxidation in biological matrices such as blood and plasma. In bioanalysis, a general approach for the stabilization of such a molecule is to derivatize the thiol group to a more stable thioether, often requiring complex handling procedures at the clinical site. In this research, the concept of dried blood spot (DBS) on-card derivatization was evaluated to stabilize thiorphan. DBS cards were in-house pre-treated with 2-bromo-3'-methoxyacetophenone and left to dry prior to blood spotting. Thiorphan was shown to be effectively derivatized to thiorphan-methoxyacetophenone once applied on the in-house pre-treated cards. Thiorphan-methoxyacetophenone was extracted by soaking a 6 mm DBS punch in methanol containing the internal standard (thiorphan-methoxyacetophenone-D₅). Chromatographic separation was achieved on a Waters XBridge C₁₈ column with a gradient elution of 5 mM NH₄HCO₃ and methanol in 2.5 min and detection by ESI(+)/MS/MS. A linear (weighted 1/x²) relationship was obtained over a concentration range of 5.00-600.00 ng/mL. The assay met regulatory guidelines acceptance criteria for sensitivity, selectivity, precision and accuracy, matrix effect, recovery, dilution integrity and multiple stability evaluations. The DBS on-card derivatization has shown to be an easy and reliable alternative form of sample collection for the quantification of thiorphan. Copyright © 2012 John Wiley & Sons, Ltd.

  3. Fast quantification of short chain fatty acids and ketone bodies by liquid chromatography-tandem mass spectrometry after facile derivatization coupled with liquid-liquid extraction.

    Science.gov (United States)

    Zeng, Mingfei; Cao, Huachuan

    2018-04-15

    Short chain fatty acids (SCFA) and ketone bodies recently emerged as important physiological relevant metabolites because of their association with microbiota, immunology, obesity and other metabolic states. They were commonly analyzed by GC-MS with long run time and laborious sample preparation. In this study we developed a novel LC-MS/MS method using fast derivatization coupled with liquid-liquid extraction to detect SCFA and ketone bodies in plasma and feces. Several different derivatization reagents were evaluated to compare the efficiency, the sensitivity and chromatographic separation of structural isomers. O‑benzylhydroxylamine was selected for its superior overall performance in reaction time and isomeric separation that allowed the measurement of each SCFAs and ketone bodies free from interferences. The derivatization procedure is facile and reproducible in aqueous-organic medium, which abolished the evaporation procedure hampering the analysis of volatile short chain acids. Enhancement in sensitivity remarkably improved the detection limit of SCFA and ketone bodies to sub-fmol level. This novel method was applied to quantify these metabolites in fecal and plasma samples from lean and DIO mouse. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Flow injection microfluidic device with on-line fluorescent derivatization for the determination of Cr(III) and Cr(VI) in water samples after solid phase extraction

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Guilong [Key Laboratory of Eco-Environment of Three Gorges Region of Ministry of Education, Chongqing University, Chongqing, 400045 (China); Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, Tsinghua University, Beijing, 100084 (China); He, Qiang, E-mail: heqiang0980@163.com [Key Laboratory of Eco-Environment of Three Gorges Region of Ministry of Education, Chongqing University, Chongqing, 400045 (China); Lu, Ying [Department of Mathematics and Physics, Armed Police College, Chengdu, 610213 (China); Huang, Jing [Research Center for Advanced Computation, College of Science, Xihua University, Chengdu, 610039 (China); Lin, Jin-Ming, E-mail: jmlin@mail.tsinghua.edu.cn [Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, Tsinghua University, Beijing, 100084 (China)

    2017-02-22

    In this paper, a rapid and simple method using magnetic multi-walled carbon nanotubes (MWCNTS), as a solid-phase extraction (SPE) sorbent, was successfully developed for extraction and preconcentration trace amounts of Cr(III) in water samples. The synthesized magnetic-MWCNTs nanocomposite was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD). A rhodamine derivative (R1) was synthesized and characterized as a highly selective and sensitive fluorescent derivatizing agent for Cr(III). After SPE procedure, Cr(III) analysis was performed by flow injection microfluidic chip with on-line fluorescent derivatization and laser-induced fluorescence (LIF) spectroscopy detection. The parameters, which affected the efficiency of the developed method were investigated and optimized. Under the optimized conditions, the method exhibited a linear dynamic range of 0–10.0 nM, with a detection limit of 0.094 nM and an enrichment factor of 38. Furthermore, real water samples were analyzed and good recoveries were obtained from 91.0 to 101.6%. - Graphical abstract: Flow injection microfluidic device with on-line fluorescent derivatization and detection coupled to LIF. - Highlights: • A highly selective and sensitive derivatizing reagent for Cr(III) was synthesized and characterized. • The magnetic-MWCNTs nanocomposite as a SPE sorbent was successfully synthesized and characterized. • A new portable detection system was developed for microfluidic chip FIA platform.

  5. In situ derivatization-ultrasound-assisted dispersive liquid-liquid microextraction for the determination of neurotransmitters in Parkinson's rat brain microdialysates by ultra high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    He, Yongrui; Zhao, Xian-En; Zhu, Shuyun; Wei, Na; Sun, Jing; Zhou, Yubi; Liu, Shu; Liu, Zhiqiang; Chen, Guang; Suo, Yourui; You, Jinmao

    2016-08-05

    Simultaneous monitoring of several neurotransmitters (NTs) linked to Parkinson's disease (PD) has important scientific significance for PD related pathology, pharmacology and drug screening. A new simple, fast and sensitive analytical method, based on in situ derivatization-ultrasound-assisted dispersive liquid-liquid microextraction (in situ DUADLLME) in a single step, has been proposed for the quantitative determination of catecholamines and their biosynthesis precursors and metabolites in rat brain microdialysates. The method involved the rapid injection of the mixture of low toxic bromobenzene (extractant) and acetonitrile (dispersant), which containing commercial Lissamine rhodamine B sulfonyl chloride (LRSC) as derivatization reagent, into the aqueous phase of sample and buffer, and the following in situ DUADLLME procedure. After centrifugation, 50μL of the sedimented phase (bromobenzene) was directly injected for ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) detection in multiple reaction monitoring (MRM) mode. This interesting combination brought the advantages of speediness, simpleness, low matrix effects and high sensitivity in an effective way. Parameters of in situ DUADLLME and UHPLC-MS/MS conditions were all optimized in detail. The optimum conditions of in situ DUADLLME were found to be 30μL of microdialysates, 150μL of acetonitrile containing LRSC, 50μL of bromobenzene and 800μL of NaHCO3-Na2CO3 buffer (pH 10.5) for 3.0min at 37°C. Under the optimized conditions, good linearity was observed with LODs (S/N>3) and LOQs (S/N>10) of LRSC derivatized-NTs in the range of 0.002-0.004 and 0.007-0.015 nmol/L, respectively. It also brought good precision (3.2-12.8%, peak area CVs%), accuracy (94.2-108.6%), recovery (94.5-105.5%) and stability (3.8-8.1%, peak area CVs%) results. Moreover, LRSC derivatization significantly improved chromatographic resolution and MS detection sensitivity of NTs when compared with the

  6. Analysis of Glyphosate and Aminomethylphosphonic Acid in Nutritional Ingredients and Milk by Derivatization with Fluorenylmethyloxycarbonyl Chloride and Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Ehling, Stefan; Reddy, Todime M

    2015-12-09

    A straightforward analytical method based on derivatization with fluorenylmethyloxycarbonyl chloride and liquid chromatography-mass spectrometry has been developed for the analysis of residues of glyphosate and aminomethylphosphonic acid (AMPA) in a suite of nutritional ingredients derived from soybean, corn, and sugar beet and also in cow's milk and human breast milk. Accuracy and intermediate precision were 91-116% and soy protein isolate. Limits of quantitation were 0.05 and 0.005 μg/g in powdered and liquid samples, respectively. Glyphosate and AMPA were quantified at 0.105 and 0.210 μg/g (soy protein isolate) and 0.850 and 2.71 μg/g (soy protein concentrate, both derived from genetically modified soybean), respectively. Residues were not detected in soy milk, soybean oil, corn oil, maltodextrin, sucrose, cow's milk, whole milk powder, or human breast milk. The method is proposed as a convenient tool for the survey of glyphosate and AMPA in the ingredient supply chain.

  7. Development and application of compact denuder sampling techniques with in situ derivatization followed by gas chromatography-mass spectrometry for halogen speciation in volcanic plumes

    Science.gov (United States)

    Rüdiger, Julian; Bobrowski, Nicole; Hoffmann, Thorsten

    2015-04-01

    Volcanoes are a large source for several reactive atmospheric trace gases including sulphur and halogen containing species. The detailed knowledge of volcanic plume chemistry can give insights into subsurface processes and can be considered as a useful geochemical tool for monitoring of volcanic activity, especially halogen to sulphur ratios (e.g. Bobrowski and Giuffrida, 2012; Donovan et al., 2014). The reactive bromine species bromine monoxide (BrO) is of particular interest, because BrO as well as SO2 are readily measurable by UV spectrometers at a safe distance. Furthermore it is formed in the plume by a multiphase reaction mechanism under depletion of ozone in the plume. The abundance of BrO changes as a function of the reaction time and therefore distance from the vent as well as the spatial position in the plume. Due to the lack of analytical approaches for the accurate speciation of certain halogens (HBr, Br2, Br, BrCl, HOBr etc.) there are still uncertainties about the magnitude of volcanic halogen emissions and in particular their specificationtheir species and therefore also in the understanding of the bromine chemistry in volcanic plumes (Bobrowski et al., 2007). In this study, the first application of a 1,3,5-trimethoxybenzene (1,3,5-TMB)-coated gas diffusion denuder (Huang and Hoffmann, 2008) on volcanic gases proved to be suitable to collect selectively gaseous bromine species with oxidation states of +1 or 0 (Br2 and BrO(H)), while being ignorant to HBr (OS -1). The reaction of 1,3,5-TMB with bromine gives 1-bromo-2,4,6-trimethoxybenzene (1-bromo-2,4,6-TMB) - other halogens give corresponding products. The diffusion denuder technique allows sampling of gaseous compounds exclusively without collecting particulate matter. Choosing a flow rate of 500 mL-min-1 and a denuder length of 0.5 m a nearly quantitative collection efficiency was achieved. Solvent elution of the derivatized analytes and subsequent analysis with gas chromatography-mass

  8. Highly sensitive and specific derivatization strategy to profile and quantitate eicosanoids by UPLC-MS/MS

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Ting; Tie, Cai; Wang, Zhe; Zhang, Jin-Lan, E-mail: zhjl@imm.ac.cn

    2017-01-15

    Eicosanoids are signaling molecules mainly oxidized from arachidonic acid (ARA) and eicosapentaenoic acid (EPA) or docosahexaenoic acid (DHA). They have attracted increasing attention from the scientists attributing to their essential physiological functions. However, their quantification have long been challenged by the low abundance, high structure similarity, poor stability and limited ionization efficiency. In this paper, an ultra-high performance liquid chromatograph coupled with tandem mass spectrometry (UPLC-MS/MS) strategy was developed for the comprehensive profiling of more than 60 eicosanoids based on an efficient derivatization reagent 2,4-bis(diethylamino)-6-hydrazino-1,3,5-triazine (T3) and general multiple reaction monitoring (MRM) parameters. Carboxylic acid of eicosanoid was converted to amide in 30 min at 4 °C with derivatization yield larger than 99%. Limits of quantitation (LOQs) for derivatized eicosanoids varied from 0.05 to 50 pg depending on their structures. The sensitivities of derivatized eicosanoids were enhanced by 10- to 5000-folds compared to free eicosanoids. Stabilities of T3 modified eicosanoids were also highly improved compared to free eicosanoids. This new method can also be used to quantify eicosanoids in bio-samples using isotopic internal standards with high efficiency and reliability within 19 min. 46 and 50 eicosanoids in rat plasma and heart tissue from control and acute myocardial ischemia (AMI) model rats were respectively profiled and quantitated using this new method. And 24 of 46 and 25 of 50 eicosanoids were found to be significantly changed between control and model groups. The changed eicosanoids related to AMI modeling were further statistically analyzed and interpreted based on eicosanoid metabolism pathway. - Highlights: • Eicosanoids are important signaling molecules. • A highly sensitive and specific derivatization strategy was developed for eicosanoid profiling. • The strategy was employed for

  9. Highly sensitive and specific derivatization strategy to profile and quantitate eicosanoids by UPLC-MS/MS

    International Nuclear Information System (INIS)

    Hu, Ting; Tie, Cai; Wang, Zhe; Zhang, Jin-Lan

    2017-01-01

    Eicosanoids are signaling molecules mainly oxidized from arachidonic acid (ARA) and eicosapentaenoic acid (EPA) or docosahexaenoic acid (DHA). They have attracted increasing attention from the scientists attributing to their essential physiological functions. However, their quantification have long been challenged by the low abundance, high structure similarity, poor stability and limited ionization efficiency. In this paper, an ultra-high performance liquid chromatograph coupled with tandem mass spectrometry (UPLC-MS/MS) strategy was developed for the comprehensive profiling of more than 60 eicosanoids based on an efficient derivatization reagent 2,4-bis(diethylamino)-6-hydrazino-1,3,5-triazine (T3) and general multiple reaction monitoring (MRM) parameters. Carboxylic acid of eicosanoid was converted to amide in 30 min at 4 °C with derivatization yield larger than 99%. Limits of quantitation (LOQs) for derivatized eicosanoids varied from 0.05 to 50 pg depending on their structures. The sensitivities of derivatized eicosanoids were enhanced by 10- to 5000-folds compared to free eicosanoids. Stabilities of T3 modified eicosanoids were also highly improved compared to free eicosanoids. This new method can also be used to quantify eicosanoids in bio-samples using isotopic internal standards with high efficiency and reliability within 19 min. 46 and 50 eicosanoids in rat plasma and heart tissue from control and acute myocardial ischemia (AMI) model rats were respectively profiled and quantitated using this new method. And 24 of 46 and 25 of 50 eicosanoids were found to be significantly changed between control and model groups. The changed eicosanoids related to AMI modeling were further statistically analyzed and interpreted based on eicosanoid metabolism pathway. - Highlights: • Eicosanoids are important signaling molecules. • A highly sensitive and specific derivatization strategy was developed for eicosanoid profiling. • The strategy was employed for

  10. Development and application of denuder sampling techniques with in situ derivatization for the determination of hydrogenbromide in volcanic plumes

    Science.gov (United States)

    Gutmann, Alexandra; Rüdiger, Julian; Hoffmann, Thorsten

    2016-04-01

    The composition of gases in volcanic plumes shifts with subsurface processes inside volcanoes. For monitoring volcanic activity by studying volcanic plumes it is essential to understand the chemical reactions inside the volcanic plume (Bobrowski and Platt, 2013). Measurements of BrO/SO2-ratio already enable insights into magmatic processes (Bobrowski and Giuffrida, 2012). Both, BrO and SO2, are measurable by Remote Sensing Techniques at a safe distance. Models suggest not a direct emission of BrO but formation due to photochemical and multiphase reactions in the gas and particle phase. These model presume HBr as first emitted species (Gerlach, 2004). So HBr is an important connecting link between easily measurable BrO/SO2-ratios and conclusions on a volcanic system. It is of high importance to know if there is a variation in the amount of HBr transformed into BrO and to gain knowledge on the factor of its dependence. Apart from depletion of surrounded ozone also decreasing or depletion of emitted HBr or even HCl could be responsible for the shift (Bobrowski and Giuffrida, 2012). Knowledge about complex processes in volcanic plumes will simplify interpretation and predictions. In this study, first applications of coated gas diffusion denuder (similar to Huang and Hoffmann, 2008) to derivatize gaseous HBr were successful. Due to the lack of adequate remote sensing techniques an in situ method was developed and will be presented in detail. The epoxide of oleic acid was determined as a suitable derivatization agent. The reaction with HBr gives 10-bromo-9-hydroxyoctadecanoic acid. Other hydrogenhalogens give corresponding products. Derivatized analytes were removed from denuder by solvent elution and subsequent analysed with gas chromatography-mass spectrometry. A limit of quantification below 1 ng was achieved. The method was applied on volcanic gas plumes at Mt. Etna in Italy in July and August 2015. The results showed HBr in higher ppt-range. These first proof

  11. Halogen speciation in volcanic plumes - Development of compact denuder sampling techniques with in-situ derivatization followed by gas chromatography-mass spectrometry and their application at Mt. Etna, Mt. Nyiragongo and Mt. Nyamulagira in 2015.

    Science.gov (United States)

    Rüdiger, Julian; Bobrowski, Nicole; Hoffmann, Thorsten

    2016-04-01

    products. The diffusion denuder technique allows sampling of gaseous compounds exclusively without collecting particulate matter. Solvent elution of the derivatized analytes and subsequent analysis with gas chromatography-mass spectrometry gives a limit of detection below 1 ng of bromine. The method was applied in 2015 on volcanic gas plumes at Mt. Etna (Italy), Mt. Nyiragongo and Mt. Nyamulagira (DR Congo) giving reactive bromine mixing ratios from 0.3 ppb (Nyiragongo) up to 22 ppb (Etna, NEC). Compared with total halogen data derived by alkaline trap sampling (Raschig-tube) and ion-chromatography analysis the reactive bromine mixing ratios allow the investigation of the conversion of HBr into reactive species due to plume chemistry with progressing plume age. The new method will be described in detail and the first results on the reactive halogen to total halogen output will be discussed (for bromine and chlorine) and compared to earlier volcanic plume chemistry model studies. References Bobrowski, N. and G. Giuffrida: Bromine monoxide / sulphur dioxide ratios in relation to volcanological observations at Mt. Etna 2006-2009. Solid Earth, 3, 433-445, 2012 Bobrowski, N., R. von Glasow, A. Aiuppa, S. Inguaggiato, I. Louban, O. W. Ibrahim and U. Platt: Reactive halogen chemistry in volcanic plumes. J. Geophys. Res., 112, 2007 Donovan A., V. Tsanev, C. Oppenheimer and M. Edmonds: Reactive halogens (BrO and OClO) detected in the plume of Soufrière Hills Volcano during an eruption hiatus. Geochem. Geophys. Geosyst., 15, 3346-3363, 2014 Rüdiger, J., N. Bobrowski, T. Hoffmann (2015), Development and application of compact denuder sampling techniques with in situ derivatization followed by gas chromatography-mass spectrometry for halogen speciation in volcanic plumes (EGU2015-2392-2), EGU General Assembly 2015

  12. Quantification of Carbonyl Compounds Generated from Ozone-Based Food Colorants Decomposition Using On-Fiber Derivatization-SPME-GC-MS

    Directory of Open Access Journals (Sweden)

    Wenda Zhu

    2014-12-01

    Full Text Available Fruit leathers (FLs production produces some not-to-specification material, which contains valuable ingredients like fruit pulp, sugars and acidulates. Recovery of FL for product recycling requires decolorization. In earlier research, we proved the efficiency of an ozone-based decolorization process; however, it produces carbonyls as major byproducts, which could be of concern. A headspace solid-phase microextraction with on-fiber derivatization followed by gas chromatography-mass spectrometry was developed for 10 carbonyls analysis in ozonated FL solution/suspension. Effects of dopant concentration, derivatization temperature and time were studied. The adapted method was used to analyze ozonated FL solution/suspension samples. Dopant concentration and derivatization temperature were optimized to 17 mg/mL and 60 °C, respectively. Competitive extraction was studied, and 5 s extraction time was used to avoid non-linear derivatization of 2-furfural. The detection limits (LODs for target carbonyls ranged from 0.016 and 0.030 µg/L. A much lower LOD (0.016 ppb for 2-furfural was achieved compared with 6 and 35 ppb in previous studies. Analysis results confirmed the robustness of the adapted method for quantification of carbonyls in recycled process water treated with ozone-based decolorization. Ethanal, hexanal, 2-furfural, and benzaldehyde were identified as byproducts of known toxicity but all found below levels for concern.

  13. A proteomics method using immunoaffinity fluorogenic derivatization-liquid chromatography/tandem mass spectrometry (FD-LC-MS/MS) to identify a set of interacting proteins.

    Science.gov (United States)

    Nakata, Katsunori; Saitoh, Ryoichi; Ishigai, Masaki; Imai, Kazuhiro

    2018-02-01

    Biological functions in organisms are usually controlled by a set of interacting proteins, and identifying the proteins that interact is useful for understanding the mechanism of the functions. Immunoprecipitation is a method that utilizes the affinity of an antibody to isolate and identify the proteins that have interacted in a biological sample. In this study, the FD-LC-MS/MS method, which involves fluorogenic derivatization followed by separation and quantification by HPLC and finally identification of proteins by HPLC-tandem mass spectrometry, was used to identify proteins in immunoprecipitated samples, using heat shock protein 90 (HSP90) as a model of an interacting protein in HepaRG cells. As a result, HSC70 protein, which was known to form a complex with HSP90, was isolated, together with three different types of HSP90-beta. The results demonstrated that the proposed immunoaffinity-FD-LC-MS/MS method could be useful for simultaneously detecting and identifying the proteins that interact with a certain protein. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Simple determination of hydrazine in waste water by headspace solid-phase micro extraction and gas chromatography-tandem mass spectrometry after derivatization with trifluoro pentanedione.

    Science.gov (United States)

    Oh, Jin-Aa; Shin, Ho-Sang

    2017-01-15

    A headspace solid-phase micro extraction (HS-SPME) and gas chromatography-tandem mass spectrometric (GC-MS/MS) method is described to detect hydrazine after derivatization with 1,1,1-trifluoro-2,4-pentanedione (1,1,1-TFPD) to 3-methyl-5-(trifluoromethyl) pyrazole in industrial waste water. The following optimal HS-SPME conditions were used: 85 μm-carboxen-polydimethylsiloxane fibre, 100 mg L -1 TFPD, saturated NaCl, an extraction/derivatization temperature of 80 °C, a heating time of 40 min, and a pH of 9.5. Under the established conditions, the detection and quantification limits were 0.002 μg L -1 and 0.007 μg L -1  by using 5 mL of waste water and the intra- and inter-day relative standard deviations were less than 10.2% at concentrations of 0.02 and 0.1 μg L -1 . The calibration curve showed good linearity, with r 2  = 0.998; the accuracy was in the range of 98.0-103%; and the precision of the assay was less than 10.2% in industrial waste water. Hydrazine was detected over a concentration range of 0.011-0.074 μg L -1 in 5 of 20 waste water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Determination of Diacetyl in Beer by a Precolumn Derivatization-HPLC-UV Method Using 4-(2,3-Dimethyl-6-quinoxalinyl)-1,2-benzenediamine as a Derivatizing Reagent.

    Science.gov (United States)

    Wang, Ji-Yu; Wang, Xin-Jie; Hui, Xian; Hua, Shui-Hong; Li, Heng; Gao, Wen-Yun

    2017-03-29

    Diacetyl is an important flavoring compound in many foods, especially in beer. In the present study, we developed and validated a new precolumn derivatization HPLC-UV method for the determination of diacetyl using 4-(2,3-dimethyl-6-quinoxalinyl)-1,2-benzenediamine as a novel derivatizing reagent. After derivatization with the reagent at a pH value 4.0 at ambient temperature for 10 min, diacetyl was analyzed on an ODS column and detected at 254 nm. The results show that the correlation coefficient of the method is 0.9991 in the range of 0.10 to 100.0 μM diacetyl, and the limit of detection is 0.02 μM. The method was further evaluated in the analysis of beer samples with the recoveries ranging from 94.4 to 102.6% and RSDs from 1.36 to 3.33%. The concentrations of diacetyl in 8 beer samples were determined in the range of 0.19 to 0.42 μM. The method established in this study may be well suitable for the determination of diacetyl in beer.

  16. Mercury speciation and analysis in drinking water by stir bar sorptive extraction with in situ propyl derivatization and thermal desorption-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Ito, Rie; Kawaguchi, Migaku; Sakui, Norihiro; Honda, Hidehiro; Okanouchi, Noriya; Saito, Koichi; Nakazawa, Hiroyuki

    2008-10-31

    A method for mercury analysis and speciation in drinking water was developed, which involved stir bar sorptive extraction (SBSE) with in situ propyl derivatization and thermal desorption (TD)-GC-MS. Ten millilitre of tap water or bottled water was used. After a stir bar, pH adjustment agent and derivatization reagent were added, SBSE was performed. Then, the stir bar was subjected to TD-GC-MS. The detection limits were 0.01 ng mL(-1) (ethylmercury; EtHg), 0.02 ng mL(-1) (methylmercury; MeHg), and 0.2 ng mL(-1) (Hg(II) and diethylmercury (DiEtHg)). The method showed good linearity and correlation coefficients. The average recoveries of mercury species (n=5) in water samples spiked with 0.5, 2.0, and 6.0 ng mL(-1) mercury species were 93.1-131.1% (RSDmercury species in water samples.

  17. Ionic liquid-based microwave-assisted dispersive liquid-liquid microextraction and derivatization of sulfonamides in river water, honey, milk, and animal plasma

    Energy Technology Data Exchange (ETDEWEB)

    Xu Xu; Su Rui; Zhao Xin; Liu Zhuang; Zhang Yupu; Li Dan; Li Xueyuan; Zhang Hanqi [College of Chemistry, Jilin University, Changchun 130012 (China); Wang Ziming, E-mail: analchem@jlu.edu.cn [College of Chemistry, Jilin University, Changchun 130012 (China)

    2011-11-30

    Graphical abstract: The extraction and derivatization efficiency of SAs is dependent on type and volume of extraction solvent, type and volume of disperser, microwave power and irradiation time, volume of derivatization reagent, pH of sample solution as well as ionic strength. Highlights: Black-Right-Pointing-Pointer A new, rapid and sensitive method for determining sulfonamides (SAs) was proposed. Black-Right-Pointing-Pointer Derivatization, extraction and preconcentration of SAs were performed in one step. Black-Right-Pointing-Pointer IL-based MADLLME and derivatization were first applied for the determination of SAs. Black-Right-Pointing-Pointer Trace SAs in river water, honey, milk, and pig plasma were determined. - Abstract: The ionic liquid-based microwave-assisted dispersive liquid-liquid microextraction (IL-based MADLLME) and derivatization was applied for the pretreatment of six sulfonamides (SAs) prior to the determination by high-performance liquid chromatography (HPLC). By adding methanol (disperser), fluorescamine solution (derivatization reagent) and ionic liquid (extraction solvent) into sample, extraction, derivatization, and preconcentration were continuously performed. Several experimental parameters, such as the type and volume of extraction solvent, the type and volume of disperser, amount of derivatization reagent, microwave power, microwave irradiation time, pH of sample solution, and ionic strength were investigated and optimized. When the microwave power was 240 W, the analytes could be derivatized and extracted simultaneously within 90 s. The proposed method was applied to the analysis of river water, honey, milk, and pig plasma samples, and the recoveries of analytes obtained were in the range of 95.0-110.8, 95.4-106.3, 95.0-108.3, and 95.7-107.7, respectively. The relative standard deviations varied between 1.5% and 7.3% (n = 5). The results showed that the proposed method was a rapid, convenient and feasible method for the determination

  18. Ionic liquid-based microwave-assisted dispersive liquid–liquid microextraction and derivatization of sulfonamides in river water, honey, milk, and animal plasma

    International Nuclear Information System (INIS)

    Xu Xu; Su Rui; Zhao Xin; Liu Zhuang; Zhang Yupu; Li Dan; Li Xueyuan; Zhang Hanqi; Wang Ziming

    2011-01-01

    Graphical abstract: The extraction and derivatization efficiency of SAs is dependent on type and volume of extraction solvent, type and volume of disperser, microwave power and irradiation time, volume of derivatization reagent, pH of sample solution as well as ionic strength. Highlights: ► A new, rapid and sensitive method for determining sulfonamides (SAs) was proposed. ► Derivatization, extraction and preconcentration of SAs were performed in one step. ► IL-based MADLLME and derivatization were first applied for the determination of SAs. ► Trace SAs in river water, honey, milk, and pig plasma were determined. - Abstract: The ionic liquid-based microwave-assisted dispersive liquid–liquid microextraction (IL-based MADLLME) and derivatization was applied for the pretreatment of six sulfonamides (SAs) prior to the determination by high-performance liquid chromatography (HPLC). By adding methanol (disperser), fluorescamine solution (derivatization reagent) and ionic liquid (extraction solvent) into sample, extraction, derivatization, and preconcentration were continuously performed. Several experimental parameters, such as the type and volume of extraction solvent, the type and volume of disperser, amount of derivatization reagent, microwave power, microwave irradiation time, pH of sample solution, and ionic strength were investigated and optimized. When the microwave power was 240 W, the analytes could be derivatized and extracted simultaneously within 90 s. The proposed method was applied to the analysis of river water, honey, milk, and pig plasma samples, and the recoveries of analytes obtained were in the range of 95.0–110.8, 95.4–106.3, 95.0–108.3, and 95.7–107.7, respectively. The relative standard deviations varied between 1.5% and 7.3% (n = 5). The results showed that the proposed method was a rapid, convenient and feasible method for the determination of SAs in liquid samples.

  19. Graphene-Derivatized Silica Composite as Solid-Phase Extraction Sorbent Combined with GC–MS/MS for the Determination of Polycyclic Musks in Aqueous Samples

    Directory of Open Access Journals (Sweden)

    Cheng Li

    2018-02-01

    Full Text Available Polycyclic musks (PCMs have recently received growing attention as emerging contaminants because of their bioaccumulation and potential ecotoxicological effects. Herein, an effective method for the determination of five PCMs in aqueous samples is presented. Reduced graphene oxide-derivatized silica (rGO@silica particles were prepared from graphene oxide and aminosilica microparticles and characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, and X-ray photoelectron spectroscopy. PCMs were preconcentrated using rGO@silica as the solid-phase extraction sorbent and quantified by gas chromatography–tandem mass spectrometry. Several experimental parameters, such as eluent, elution volume, sorbent amount, pH, and sample volume were optimized. The correlation coefficient (R ranged from 0.9958 to 0.9992, while the limits of detection and quantitation for the five PCMs were 0.3–0.8 ng/L and 1.1–2.1 ng/L, respectively. Satisfactory recoveries were obtained for tap water (86.6–105.9% and river water samples (82.9–107.1%, with relative standard deviations <10% under optimal conditions. The developed method was applied to analyze PCMs in tap and river water samples from Beijing, China. Galaxolide (HHCB and tonalide (AHTN were the main PCM components detected in one river water sample at concentrations of 18.7 for HHCB, and 11.7 ng/L for AHTN.

  20. Profiling and relative quantification of phosphatidylethanolamine based on acetone stable isotope derivatization.

    Science.gov (United States)

    Wang, Xiang; Wei, Fang; Xu, Ji-Qu; Lv, Xin; Dong, Xu-Yan; Han, Xianlin; Quek, Siew-Young; Huang, Feng-Hong; Chen, Hong

    2016-01-01

    Phosphatidylethanolamine (PE) is considered to be one of the pivotal lipids for normal cellular function as well as disease initiation and progression. In this study, a simple, efficient, reliable, and inexpensive method for the qualitative analysis and relative quantification of PE, based on acetone stable isotope derivatization combined with double neutral loss scan-shotgun electrospray ionization tandem-quadrupole mass spectrometry analysis (ASID-DNLS-Shotgun ESI-MS/MS), was developed. The ASID method led to alkylation of the primary amino groups of PE with an isopropyl moiety. The use of acetone (d0-acetone) and deuterium-labeled acetone (d6-acetone) introduced a 6 Da mass shift that was ideally suited for relative quantitative analysis, and enhanced sensitivity for mass analysis. The DNLS model was introduced to simultaneously analyze the differential derivatized PEs by shotgun ESI-MS/MS with high selectivity and accuracy. The reaction specificity, labeling efficiency, and linearity of the ASID method were thoroughly evaluated in this study. Its excellent applicability was validated by qualitative and relative quantitative analysis of PE species presented in liver samples from rats fed different diets. Using the ASID-DNLS-Shotgun ESI-MS/MS method, 45 PE species from rat livers have been identified and quantified in an efficient manner. The level of total PEs tended to decrease in the livers of rats on high fat diets compared with controls. The levels of PE 32:1, 34:3, 34:2, 36:3, 36:2, 42:10, plasmalogen PE 36:1 and lyso PE 22:6 were significantly reduced, while levels of PE 36:1 and lyso PE 16:0 increased. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. [Determination of four phenolic endocrine disruptors in environmental water samples by high performance liquid chromatography-fluorescence detection using dispersive liquid-liquid microextraction coupled with derivatization].

    Science.gov (United States)

    Wang, Xiaoyan; Qi, Weimei; Zhao, Xian'en; Lü, Tao; Wang, Xiya; Zheng, Longfang; Yan, Yehao; You, Jinmao

    2014-06-01

    To achieve accurate, fast and sensitive detection of phenolic endocrine disruptors in small volume of environmental water samples, a method of dispersive liquid-liquid microextraction (DLLME) coupled with fluorescent derivatization was developed for the determination of bisphenol A, nonylphenol, octylphenol and 4-tert-octylphenol in environmental water samples by high performance liquid chromatography-fluorescence detection (HPLC-FLD). The DLLME and derivatization conditions were investigated, and the optimized DLLME conditions for small volume of environmental water samples (pH 4.0) at room temperature were as follows: 70 microL chloroform as extraction solvent, 400 microL acetonitrile as dispersing solvent, vortex mixing for 3 min, and then high-speed centrifugation for 2 min. Using 2-[2-(7H-dibenzo [a, g] carbazol-7-yl)-ethoxy] ethyl chloroformate (DBCEC-Cl) as precolumn derivatization reagent, the stable derivatives of the four phenolic endocrine disruptors were obtained in pH 10.5 Na2CO3-NaHCO3 buffer/acetonitrile at 50 degrees C for 3 min, and then separated within 10 min by HPLC-FLD. The limits of detection (LODs) were in the range of 0.9-1.6 ng/L, and the limits of quantification (LOQs) were in the range of 3.8-7.1 ng/L. This method had perfect linearity, precision and recovery results, and showed obvious advantages and practicality comparing to the previously reported methods. It is a convenient and validated method for the routine analysis of phenolic endocrine disruptors in waste water of paper mill, lake water, domestic wastewater, tap water, etc.

  2. A Direct Aqueous Derivatization GSMS Method for Determining Benzoylecgonine Concentrations in Human Urine.

    Science.gov (United States)

    Chericoni, Silvio; Stefanelli, Fabio; Da Valle, Ylenia; Giusiani, Mario

    2015-09-01

    A sensitive and reliable method for extraction and quantification of benzoylecgonine (BZE) and cocaine (COC) in urine is presented. Propyl-chloroformate was used as derivatizing agent, and it was directly added to the urine sample: the propyl derivative and COC were then recovered by liquid-liquid extraction procedure. Gas chromatography-mass spectrometry was used to detect the analytes in selected ion monitoring mode. The method proved to be precise for BZE and COC both in term of intraday and interday analysis, with a coefficient of variation (CV)0.999 and >0.997, respectively) within the range investigated. The method, applied to thirty authentic samples, showed to be very simple, fast, and reliable, so it can be easily applied in routine analysis for the quantification of BZE and COC in urine samples. © 2015 American Academy of Forensic Sciences.

  3. Sensitive determination of melamine in milk and powdered infant formula samples by high-performance liquid chromatography using dabsyl chloride derivatization followed by dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Faraji, M; Adeli, M

    2017-04-15

    A new and sensitive pre-column derivatization with dabsyl chloride followed by dispersive liquid-liquid microextraction was developed for the analysis of melamine (MEL) in raw milk and powdered infant formula samples by high performance liquid chromatography (HPLC) with visible detection. Derivatization with dabsyl chloride leads to improving sensitivity and hydrophobicity of MEL. Under optimum conditions of derivatization and microextraction steps, the method yielded a linear calibration curve ranging from 1.0 to 500μgL -1 with a determination coefficient (R 2 ) of 0.9995. Limit of detection and limit of quantification were 0.1 and 0.3μgL -1 , respectively. The relative standard deviation (RSD%) for intra-day (repeatability) and inter-day (reproducibility) at 25 and 100μgL -1 levels of MEL was less than 7.0% (n=6). Finally, the proposed method was successfully applied for the preconcentration and determination of MEL in different raw milk and powdered infant formula, and satisfactory results were obtained (relative recovery ⩾94%). Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Determination of biomass burning tracers in air samples by GC/MS

    Science.gov (United States)

    Janoszka, Katarzyna

    2018-01-01

    Levoglucosan (LG) as a main cellulose burning product at 300°C is a biomass burning tracer. LG characterize by relatively high molar mass and it is sorbed by particulate matter. In the study of air pollution monitoring LG is mainly analyzed in particulate matter, PM1 and PM2,5. The tracer create relatively high O-H…O bond and weaker C-H…O bond. Due to the hydrogen bond, LG dissolves very well in water. Analytical procedure of LG determination include: extraction, derivatization and analysis by gas chromatography coupled with mass spectrometry detector. In water samples levoglucosan is determined by liquid chromatography. The paper presents a methodology for particulate matter samples determination their analysis by gas chromatography coupled with a mass spectrometry detector. Determination of LG content in particulate matter was performed according to an analytical method based on simultaneous pyridine extraction and derivatization using N,O-bis (trimethylsilyl) trifluoroacetamide and trimethylchlorosilane mixture (BSTFA: TMCS, 99: 1).

  5. Determination of biomass burning tracers in air samples by GC/MS

    Directory of Open Access Journals (Sweden)

    Janoszka Katarzyna

    2018-01-01

    Full Text Available Levoglucosan (LG as a main cellulose burning product at 300°C is a biomass burning tracer. LG characterize by relatively high molar mass and it is sorbed by particulate matter. In the study of air pollution monitoring LG is mainly analyzed in particulate matter, PM1 and PM2,5. The tracer create relatively high O-H…O bond and weaker C-H…O bond. Due to the hydrogen bond, LG dissolves very well in water. Analytical procedure of LG determination include: extraction, derivatization and analysis by gas chromatography coupled with mass spectrometry detector. In water samples levoglucosan is determined by liquid chromatography. The paper presents a methodology for particulate matter samples determination their analysis by gas chromatography coupled with a mass spectrometry detector. Determination of LG content in particulate matter was performed according to an analytical method based on simultaneous pyridine extraction and derivatization using N,O-bis (trimethylsilyl trifluoroacetamide and trimethylchlorosilane mixture (BSTFA: TMCS, 99: 1.

  6. Sequential enzymatic derivatization coupled with online microdialysis sampling for simultaneous profiling of mouse tumor extracellular hydrogen peroxide, lactate, and glucose.

    Science.gov (United States)

    Su, Cheng-Kuan; Tseng, Po-Jen; Chiu, Hsien-Ting; Del Vall, Andrea; Huang, Yu-Fen; Sun, Yuh-Chang

    2017-03-01

    Probing tumor extracellular metabolites is a vitally important issue in current cancer biology. In this study an analytical system was constructed for the in vivo monitoring of mouse tumor extracellular hydrogen peroxide (H 2 O 2 ), lactate, and glucose by means of microdialysis (MD) sampling and fluorescence determination in conjunction with a smart sequential enzymatic derivatization scheme-involving a loading sequence of fluorogenic reagent/horseradish peroxidase, microdialysate, lactate oxidase, pyruvate, and glucose oxidase-for step-by-step determination of sampled H 2 O 2 , lactate, and glucose in mouse tumor microdialysate. After optimization of the overall experimental parameters, the system's detection limit reached as low as 0.002 mM for H 2 O 2 , 0.058 mM for lactate, and 0.055 mM for glucose, based on 3 μL of microdialysate, suggesting great potential for determining tumor extracellular concentrations of lactate and glucose. Spike analyses of offline-collected mouse tumor microdialysate and monitoring of the basal concentrations of mouse tumor extracellular H 2 O 2 , lactate, and glucose, as well as those after imparting metabolic disturbance through intra-tumor administration of a glucose solution through a prior-implanted cannula, were conducted to demonstrate the system's applicability. Our results evidently indicate that hyphenation of an MD sampling device with an optimized sequential enzymatic derivatization scheme and a fluorescence spectrometer can be used successfully for multi-analyte monitoring of tumor extracellular metabolites in living animals. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. A novel headspace solid-phase microextraction method using in situ derivatization and a diethoxydiphenylsilane fibre for the gas chromatography-mass spectrometry determination of urinary hydroxy polycyclic aromatic hydrocarbons.

    Science.gov (United States)

    Mattarozzi, M; Musci, M; Careri, M; Mangia, A; Fustinoni, S; Campo, L; Bianchi, F

    2009-07-24

    An innovative and simple headspace solid-phase microextraction method using a novel diethoxydiphenylsilane fibre based on in situ derivatization with acetic anhydride was optimized and validated for the gas chromatography-mass spectrometry determination of some monohydroxy metabolites of polycyclic aromatic hydrocarbons, namely 1-hydroxynaphthalene, 2-hydroxynaphtalene, 9-hydroxyfluorene, 2-hydroxyfluorene and 1-hydroxypyrene at trace levels in human urine. Enzymatic hydrolysis was applied before derivatization, whereas extraction conditions, i.e. the effects of time and temperature of extraction and salt addition were investigated by experimental design. Regression models and desirability functions were applied to find the experimental conditions providing the highest global extraction response. These conditions were found in correspondence of an extraction temperature of 90 degrees C, an extraction time of 90 min and 25% NaCl added to urine samples. The capabilities of the developed method were proved obtaining limit of quantitations in the 0.1-2 microg/l range, thus allowing the bio-monitoring of these compounds in human urine. A good precision was observed both in terms of intra-batch and inter-batch repeatability with RSD always lower than 14%. Recoveries ranging from 98(+/-3) to 121(+/-1)% and extraction yields higher than 72% were also obtained. Finally, the analysis of urine specimens of coke-oven workers revealed analytes' concentrations in the 2.2-164 microg/l range, proving the exposure to PAHs of the involved workers.

  8. Identification of inorganic anions by gas chromatography/mass spectrometry.

    Science.gov (United States)

    Sakayanagi, Masataka; Yamada, Yaeko; Sakabe, Chikako; Watanabe, Kunio; Harigaya, Yoshihiro

    2006-03-10

    Inorganic anions were identified by using gas chromatography/mass spectrometry (GC/MS). Derivatization of the anions was achieved with pentafluorobenzyl p-toluenesulphonate (PFB-Tos) as the reaction reagent and a crown ether as a phase transfer catalyst. When PFB-Br was used as the reaction reagent, the retention time of it was close to those of the derivatized inorganic anions and interfered with the analysis. In contrast, the retention time of PFB-Tos differed greatly from the PFB derivatives of the inorganic anions and the compounds of interest could be detected without interference. Although the PFB derivatives of SO4, S2O3, CO3, ClO4, and ClO3 could not be detected, the derivatives of F, Cl, Br, I, CN, OCN, SCN, N3, NO3, and NO2 were detected using PFB-Tos as the derivatizing reagent. The inorganic anions were detectable within 30 ng approximately, which is of sufficient sensitivity for use in forensic chemistry. Accurate mass number was measured for each PFB derivative by high-resolution mass spectrometry (HRMS) within a measurement error of 2 millimass units (mmu), which allowed determination of the compositional formula from the mass number. In addition, actual analysis was performed successively by our method using trial samples of matrix.

  9. Analysis of primary aromatic amines using precolumn derivatization by HPLC fluorescence detection and online MS identification.

    Science.gov (United States)

    Zhao, Xianen; Suo, Yourui

    2008-03-01

    2-(2-phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA) and 2-(9-acridone)-acetic acid (AAA), two novel precolumn fluorescent derivatization reagents, have been developed and compared for analysis of primary aromatic amines by high performance liquid chromatographic fluorescence detection coupled with online mass spectrometric identification. PPIA and AAA react rapidly and smoothly with the aromatic amines on the basis of a condensation reaction using 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC) as dehydrating catalyst to form stable derivatives with emission wavelengths at 380 and 440 nm, respectively. Taking six primary aromatic amines (aniline, 2-methylaniline, 2-methoxyaniline, 4-methylaniline, 4-chloroaniline, and 4-bromoaniline) as testing compounds, derivatization conditions such as coupling reagent, basic catalyst, reaction temperature and time, reaction solvent, and fluorescent labeling reagent concentration have also been investigated. With the better PPIA method, chromatographic separation of derivatized aromatic amines exhibited a good baseline resolution on an RP column. At the same time, by online mass spectrometric identification with atmospheric pressure chemical ionization (APCI) source in positive ion mode, the PPIA-labeled derivatives were characterized by easy-to-interpret mass spectra due to the prominent protonated molecular ion m/z [M + H](+) and specific fragment ions (MS/MS) m/z 335 and 295. The linear range is 24.41 fmol-200.0 pmol with correlation coefficients in the range of 0.9996-0.9999, and detection limits of PPIA-labeled aromatic amines are 0.12-0.21 nmol/L (S/N = 3). Method repeatability, precision, and recovery were evaluated and the results were excellent for the efficient HPLC analysis. The most important argument, however, was the high sensitivity and ease-of-handling of the PPIA method. Preliminary experiments with wastewater samples collected from the waterspout of a paper mill and its nearby soil where

  10. Rapid screening of selective serotonin re-uptake inhibitors in urine samples using solid-phase microextraction gas chromatography-mass spectrometry.

    Science.gov (United States)

    Salgado-Petinal, Carmen; Lamas, J Pablo; Garcia-Jares, Carmen; Llompart, Maria; Cela, Rafael

    2005-07-01

    In this paper a solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) method is proposed for a rapid analysis of some frequently prescribed selective serotonin re-uptake inhibitors (SSRI)-venlafaxine, fluvoxamine, mirtazapine, fluoxetine, citalopram, and sertraline-in urine samples. The SPME-based method enables simultaneous determination of the target SSRI after simple in-situ derivatization of some of the target compounds. Calibration curves in water and in urine were validated and statistically compared. This revealed the absence of matrix effect and, in consequence, the possibility of quantifying SSRI in urine samples by external water calibration. Intra-day and inter-day precision was satisfactory for all the target compounds (relative standard deviation, RSD, detection limits achieved were detected and tentatively identified.

  11. Rapid qualitative analysis of 2 flavonoids, rutin and silybin, in medical pills by direct analysis in real-time mass spectrometry (DART-MS) combined with in situ derivatization.

    Science.gov (United States)

    Nagy, Tibor; Kuki, Ákos; Nagy, Lajos; Zsuga, Miklós; Kéki, Sándor

    2018-03-01

    Direct analysis in real-time mass spectrometry (DART-MS) with in situ silylation was used for the rapid analysis of the flavonoids silybin ((2R,3R)-3,5,7-trihydroxy-2-[3-(4-hydroxy-3-methoxyphenyl)-2-hydroxymethyl-2,3-dihydrobenzo[1,4]dioxin-6-yl]chroman-4-one) and rutin (quercetin-3-O-rutinoside). Three different derivatization reagents, hexamethyldisilazane/trimethylchlorosilane/pyridine (HMDS/TMCS/pyridine), N,O-bis(trimethylsilyl)acetamide/trimethylchlorosilane/N-trimethylsilyimidazole (BSA/TMCS/TMSI), and N,O-bis(trimethylsilyl)trifluoroacetamide/trimethylchlorosilane (BSTFA/TMCS), were applied. Silybin and rutin were detected with various degrees of silylation, and the formation of dimers with pyridine and imidazole was also observed. HMDS/TMCS/pyridine was the best choice for the DART-MS analysis of silybin, and BSA/TMCS/TMSI was the most effective for the detection of rutin. The effects of the DART source temperature on desorption, ionization, in-source fragmentation, dimer formation, and hydrolysis of the trimethylsilyl groups were also studied. In addition, the collision-induced dissociation properties of the derivatized silybin and rutin were explored. With our in situ silylation method, the derivatized bioactive compounds in intact medical pills could also be detected by DART-MS. Copyright © 2017 John Wiley & Sons, Ltd.

  12. ISOTOPE-DILUTION AMMONIA CHEMICAL-IONIZATION MASS FRAGMENTOGRAPHIC ANALYSIS OF URINARY 3-O-METHYLATED CATECHOLAMINE METABOLITES - RAPID SAMPLE CLEANUP BY DERIVATIZATION AND EXTRACTION OF LYOPHILIZED SAMPLES

    NARCIS (Netherlands)

    KEMA, IP; MEIBORG, G; NAGEL, GT; STOB, GJ; MUSKIET, FAJ

    1993-01-01

    We developed a method for simultaneous quantification of the urinary 3-O-methylated catecholamine metabolites 3-methoxytyramine, normetanephrine and metanephrine by stable isotope-dilution ammonia chemical ionization mass fragmentography. Prepurification of lyophilized samples was done by

  13. In situ derivatization and hollow fiber membrane microextraction for gas chromatographic determination of haloacetic acids in water

    Energy Technology Data Exchange (ETDEWEB)

    Varanusupakul, Pakorn [Chromatography and Separation Research Unit, Department of Chemistry, Faculty of Science, Chulalongkorn University, Phayathai Road, Patumwan, Bangkok 10330 (Thailand)], E-mail: pakorn.v@chula.ac.th; Vora-adisak, Narongchai; Pulpoka, Bancha [Chromatography and Separation Research Unit, Department of Chemistry, Faculty of Science, Chulalongkorn University, Phayathai Road, Patumwan, Bangkok 10330 (Thailand)

    2007-08-15

    An alternative method for gas chromatographic determination of haloacetic acids (HAAs) in water using direct derivatization followed by hollow fiber membrane liquid-phase microextraction (HF-LPME) has been developed. The method has improved the sample preparation step according to the conventional US EPA Method 552.2 by combining the derivatization and the extraction into one step prior to determination by gas chromatography electron captured detector (GC-ECD). The HAAs were derivatized with acidic methanol into their methyl esters and simultaneously extracted with supported liquid hollow fiber membrane in headspace mode. The derivatization was attempted directly in water sample without sample evaporation. The HF-LPME was performed using 1-octanol as the extracting solvent at 55 deg. C for 60 min with 20% Na{sub 2}SO{sub 4}. The linear calibration curves were observed for the concentrations ranging from 1 to 300 {mu}g L{sup -1} with the correlation coefficients (R{sup 2}) being greater than 0.99. The method detection limits of most analytes were below 1 {mu}g L{sup -1} except DCAA and MCAA that were 2 and 18 {mu}g L{sup -1}, respectively. The recoveries from spiked concentration ranged from 97 to 109% with %R.S.D. less than 12%. The method was applied for determination of HAAs in drinking water and tap water samples. The method offers an easy one step high sample throughput sample preparation for gas chromatographic determination of haloacetic acids as well as other contaminants in water.

  14. In situ derivatization and hollow fiber membrane microextraction for gas chromatographic determination of haloacetic acids in water

    International Nuclear Information System (INIS)

    Varanusupakul, Pakorn; Vora-adisak, Narongchai; Pulpoka, Bancha

    2007-01-01

    An alternative method for gas chromatographic determination of haloacetic acids (HAAs) in water using direct derivatization followed by hollow fiber membrane liquid-phase microextraction (HF-LPME) has been developed. The method has improved the sample preparation step according to the conventional US EPA Method 552.2 by combining the derivatization and the extraction into one step prior to determination by gas chromatography electron captured detector (GC-ECD). The HAAs were derivatized with acidic methanol into their methyl esters and simultaneously extracted with supported liquid hollow fiber membrane in headspace mode. The derivatization was attempted directly in water sample without sample evaporation. The HF-LPME was performed using 1-octanol as the extracting solvent at 55 deg. C for 60 min with 20% Na 2 SO 4 . The linear calibration curves were observed for the concentrations ranging from 1 to 300 μg L -1 with the correlation coefficients (R 2 ) being greater than 0.99. The method detection limits of most analytes were below 1 μg L -1 except DCAA and MCAA that were 2 and 18 μg L -1 , respectively. The recoveries from spiked concentration ranged from 97 to 109% with %R.S.D. less than 12%. The method was applied for determination of HAAs in drinking water and tap water samples. The method offers an easy one step high sample throughput sample preparation for gas chromatographic determination of haloacetic acids as well as other contaminants in water

  15. Determination of monoamine neurotransmitters in zebrafish (Danio rerio) by gas chromatography coupled to mass spectrometry with a two-step derivatization.

    Science.gov (United States)

    Aragon, Alvaro; Legradi, Jessica; Ballesteros-Gómez, Ana; Legler, Juliette; van Velzen, Martin; de Boer, Jacob; Leonards, Pim

    2017-04-01

    A sensitive analytical method for the determination of monoamine neurotransmitters (MNTs) in zebrafish larvae was developed using gas chromatography coupled to mass spectrometry. Six MNTs were selected as target compounds for neurotoxicity testing. MNTs underwent a two-step derivatization with hexamethyldisilazane (HDMS) for O-silylation followed by N-methyl-bis-heptafluorobutyramide (MBHFBA) for N-perfluoroacylation. Derivatization conditions were optimized by an experimental design approach. Method validation showed linear calibration curves (r 2  > 0.9976) in the range of 1-100 ng for all the compounds. The recovery rates were between 92 and 119%. The method was repeatable and reproducible with relative standard deviations (RSD) in the range of 2.5-9.3% for intra-day and 4.8-12% for inter-day variation. The limits of detection and the limits of quantitation were 0.4-0.8 and 1.2-2.7 ng/mL, respectively. The method was successfully applied to detect and quantify trace levels of MNTs in 5-day-old zebrafish larvae that were exposed to low concentrations of neurotoxic chemicals such as pesticides and methylmercury. Although visual malformations were not detected, the MNT levels varied significantly during early zebrafish development. These results show that exposure to neurotoxic chemicals can alter neurotransmitter levels and thereby may influence early brain development. Graphical abstract ᅟ.

  16. Application of acetone acetals as water scavengers and derivatization agents prior to the gas chromatographic analysis of polar residual solvents in aqueous samples.

    Science.gov (United States)

    van Boxtel, Niels; Wolfs, Kris; Van Schepdael, Ann; Adams, Erwin

    2015-12-18

    The sensitivity of gas chromatography (GC) combined with the full evaporation technique (FET) for the analysis of aqueous samples is limited due to the maximum tolerable sample volume in a headspace vial. Using an acetone acetal as water scavenger prior to FET-GC analysis proved to be a useful and versatile tool for the analysis of high boiling analytes in aqueous samples. 2,2-Dimethoxypropane (DMP) was used in this case resulting in methanol and acetone as reaction products with water. These solvents are relatively volatile and were easily removed by evaporation enabling sample enrichment leading to 10-fold improvement in sensitivity compared to the standard 10μL FET sample volumes for a selection of typical high boiling polar residual solvents in water. This could be improved even further if more sample is used. The method was applied for the determination of residual NMP in an aqueous solution of a cefotaxime analogue and proved to be considerably better than conventional static headspace (sHS) and the standard FET approach. The methodology was also applied to determine trace amounts of ethylene glycol (EG) in aqueous samples like contact lens fluids, where scavenging of the water would avoid laborious extraction prior to derivatization. During this experiment it was revealed that DMP reacts quantitatively with EG to form 2,2-dimethyl-1,3-dioxolane (2,2-DD) under the proposed reaction conditions. The relatively high volatility (bp 93°C) of 2,2-DD makes it possible to perform analysis of EG using the sHS methodology making additional derivatization reactions superfluous. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Ionic liquid-based microwave-assisted dispersive liquid-liquid microextraction and derivatization of sulfonamides in river water, honey, milk, and animal plasma.

    Science.gov (United States)

    Xu, Xu; Su, Rui; Zhao, Xin; Liu, Zhuang; Zhang, Yupu; Li, Dan; Li, Xueyuan; Zhang, Hanqi; Wang, Ziming

    2011-11-30

    The ionic liquid-based microwave-assisted dispersive liquid-liquid microextraction (IL-based MADLLME) and derivatization was applied for the pretreatment of six sulfonamides (SAs) prior to the determination by high-performance liquid chromatography (HPLC). By adding methanol (disperser), fluorescamine solution (derivatization reagent) and ionic liquid (extraction solvent) into sample, extraction, derivatization, and preconcentration were continuously performed. Several experimental parameters, such as the type and volume of extraction solvent, the type and volume of disperser, amount of derivatization reagent, microwave power, microwave irradiation time, pH of sample solution, and ionic strength were investigated and optimized. When the microwave power was 240 W, the analytes could be derivatized and extracted simultaneously within 90 s. The proposed method was applied to the analysis of river water, honey, milk, and pig plasma samples, and the recoveries of analytes obtained were in the range of 95.0-110.8, 95.4-106.3, 95.0-108.3, and 95.7-107.7, respectively. The relative standard deviations varied between 1.5% and 7.3% (n=5). The results showed that the proposed method was a rapid, convenient and feasible method for the determination of SAs in liquid samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Improved derivatization protocol for simultaneous determination of ...

    African Journals Online (AJOL)

    The derivatization reaction was completed in 30 min at 50°C using hexane as solvent. ... higher temperatures and shorter derivatization time, or lower temperatures ... The following were added into a pyrex test tube: 80 µℓ of organic mixture ...

  19. Microextraction with polyethersulfone for bisphenol-A, alkylphenols and hormones determination in water samples by means of gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry analysis.

    Science.gov (United States)

    Ros, O; Vallejo, A; Blanco-Zubiaguirre, L; Olivares, M; Delgado, A; Etxebarria, N; Prieto, A

    2015-03-01

    In the present work, the suitability of polyethersulfone (PES) tube was assessed for the simultaneous sorptive microextraction of commonly found endocrine disrupting compounds in natural waters such as bisphenol-A (BPA), nonylphenol technical mixture (NP mix), 4-tert-octylphenol (4tOP), 4-n-octylphenol (4-nOP), 17β-estradiol (E2) and 17α-ethynilestradiol (EE2). After the concentration of target compounds in the PES polymer, the analytes were recovered soaking the polymer with a suitable solvent (ethyl acetate or methanol), derivatized using N,O-bis(trimethylsilyl)trifluoroacetamide with 1% of trimethylchlorosilane (BSTFA+1% TMCS) and determined by gas chromatography-mass spectrometry (GC-MS). The analysis was also performed without derivatization step by means of liquid chromatography-tandem mass spectrometry (LC-MS/MS). Extraction parameters (addition of MeOH, ionic strength, extraction speed and time and desorption time) were evaluated and the optimum conditions were fixed as follows: 150 mL water samples containing a 10% (w/v) of sodium chloride and using 5 tubular PES sorbent fibers (1.5 cm length×0.7 mm o.d.). Equilibrium conditions were achieved after 9 h, with absolute extraction efficiencies ranging from 27 to 56%. On the whole, good apparent recoveries were achieved (68-103% and 81-122% for GC-MS and LC-MS/MS, respectively) using deuterated analogues as surrogates. Achieved quantification limits (LOQs) varied between 2-154 ng/L and 2-63 ng/L for all the compounds using GC-MS and LC-MS/MS, respectively. The effect of organic matter was evaluated previous to apply the final method to the analysis of estuarine and wastewater real samples. The comparison of both methods showed that overall, PES-LC-MS/MS provided shorter sample preparation time and better LODs, but PES-silylation-GC-MS allowed the simultaneous determination of all the studied compounds with adequate repeatability and accuracy. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Derivatization reaction-based surface-enhanced Raman scattering (SERS) for detection of trace acetone.

    Science.gov (United States)

    Zheng, Ying; Chen, Zhuo; Zheng, Chengbin; Lee, Yong-Ill; Hou, Xiandeng; Wu, Li; Tian, Yunfei

    2016-08-01

    A facile method was developed for determination of trace volatile acetone by coupling a derivatization reaction to surface-enhanced Raman scattering (SERS). With iodide modified Ag nanoparticles (Ag IMNPs) as the SERS substrate, acetone without obvious Raman signal could be converted to SERS-sensitive species via a chemical derivatization reaction with 2,4-dinitrophenylhydrazine (2,4-DNPH). In addition, acetone can be effectively separated from liquid phase with a purge-sampling device and then any serious interference from sample matrices can be significantly reduced. The optimal conditions for the derivatization reaction and the SERS analysis were investigated in detail, and the selectivity and reproducibility of this method were also evaluated. Under the optimal conditions, the limit of detection (LOD) for acetone was 5mgL(-1) or 0.09mM (3σ). The relative standard deviation (RSD) for 80mgL(-1) acetone (n=9) was 1.7%. This method was successfully used for the determination of acetone in artificial urine and human urine samples with spiked recoveries ranging from 92% to 110%. The present method is convenient, sensitive, selective, reliable and suitable for analysis of trace acetone, and it could have a promising clinical application in early diabetes diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. LC-MS n Analysis of Isomeric Chondroitin Sulfate Oligosaccharides Using a Chemical Derivatization Strategy

    Science.gov (United States)

    Huang, Rongrong; Pomin, Vitor H.; Sharp, Joshua S.

    2011-09-01

    Improved methods for structural analyses of glycosaminoglycans (GAGs) are required to understand their functional roles in various biological processes. Major challenges in structural characterization of complex GAG oligosaccharides using liquid chromatography-mass spectrometry (LC-MS) include the accurate determination of the patterns of sulfation due to gas-phase losses of the sulfate groups upon collisional activation and inefficient on-line separation of positional sulfation isomers prior to MS/MS analyses. Here, a sequential chemical derivatization procedure including permethylation, desulfation, and acetylation was demonstrated to enable both on-line LC separation of isomeric mixtures of chondroitin sulfate (CS) oligosaccharides and accurate determination of sites of sulfation by MS n . The derivatized oligosaccharides have sulfate groups replaced with acetyl groups, which are sufficiently stable to survive MS n fragmentation and reflect the original sulfation patterns. A standard reversed-phase LC-MS system with a capillary C18 column was used for separation, and MS n experiments using collision-induced dissociation (CID) were performed. Our results indicate that the combination of this derivatization strategy and MS n methodology enables accurate identification of the sulfation isomers of CS hexasaccharides with either saturated or unsaturated nonreducing ends. Moreover, derivatized CS hexasaccharide isomer mixtures become separable by LC-MS method due to different positions of acetyl modifications.

  2. Tandem MS Analysis of Selenamide-Derivatized Peptide Ions

    Science.gov (United States)

    Zhang, Yun; Zhang, Hao; Cui, Weidong; Chen, Hao

    2011-09-01

    Our previous study showed that selenamide reagents such as ebselen and N-(phenylseleno)phthalimide (NPSP) can be used for selective and rapid derivatization of protein/peptide thiols in high conversion yield. This paper reports the systematic investigation of MS/MS dissociation behaviors of selenamide-derivatized peptide ions upon collision induced dissociation (CID) and electron transfer dissociation (ETD). In the positive ion mode, derivatized peptide ions exhibit tag-dependent CID dissociation pathways. For instance, ebselen-derivatized peptide ions preferentially undergo Se-S bond cleavage upon CID to produce a characteristic fragment ion, the protonated ebselen ( m/z 276), which allows selective identification of thiol peptides from protein digest as well as selective detection of thiol proteins from protein mixture using precursor ion scan (PIS). In contrast, NPSP-derivatized peptide ions retain their phenylselenenyl tags during CID, which is useful in sequencing peptides and locating cysteine residues. In the negative ion CID mode, both types of tags are preferentially lost via the Se-S cleavage, analogous to the S-S bond cleavage during CID of disulfide-containing peptide anions. In consideration of the convenience in preparing selenamide-derivatized peptides and the similarity of Se-S of the tag to the S-S bond, we also examined ETD of the derivatized peptide ions to probe the mechanism for electron-based ion dissociation. Interestingly, facile cleavage of Se-S bond occurs to the peptide ions carrying either protons or alkali metal ions, while backbone cleavage to form c/z ions is severely inhibited. These results are in agreement with the Utah-Washington mechanism proposed for depicting electron-based ion dissociation processes.

  3. Accelerated identification of proteins by mass spectrometry by employing covalent pre-gel staining with Uniblue A.

    Directory of Open Access Journals (Sweden)

    Marco A Mata-Gómez

    Full Text Available BACKGROUND: The identification of proteins by mass spectrometry is a standard method in biopharmaceutical quality control and biochemical research. Prior to identification by mass spectrometry, proteins are usually pre-separated by electrophoresis. However, current protein staining and de-staining protocols are tedious and time consuming, and therefore prolong the sample preparation time for mass spectrometry. METHODOLOGY AND PRINCIPAL FINDINGS: We developed a 1-minute covalent pre-gel staining protocol for proteins, which does not require de-staining before the mass spectrometry analysis. We investigated the electrophoretic properties of derivatized proteins and peptides and studied their behavior in mass spectrometry. Further, we elucidated the preferred reaction of proteins with Uniblue A and demonstrate the integration of the peptide derivatization into typical informatics tools. CONCLUSIONS AND SIGNIFICANCE: The Uniblue A staining method drastically speeds up the sample preparation for the mass spectrometry based identification of proteins. The application of this chemo-proteomic strategy will be advantageous for routine quality control of proteins and for time-critical tasks in protein analysis.

  4. Passive sampling of ambient ozone by solid phase microextraction with on-fiber derivatization

    International Nuclear Information System (INIS)

    Lee, I-S.; Tsai, S.-W.

    2008-01-01

    The solid phase microextraction (SPME) device with the polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was used as a passive sampler for ambient ozone. Both O-2,3,4,5,6-(pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) and 1,2-di-(4-pyridyl)ethylene (DPE) were loaded onto the fiber before sampling. The SPME fiber assembly was then inserted into a PTFE tubing as a passive sampler. Known concentrations of ozone around the ambient ground level were generated by a calibrated ozone generator. Laboratory validations of the SPME passive sampler with the direct-reading ozone monitor were performed side-by-side in an exposure chamber at 25 deg. C. After exposures, pyriden-4-aldehyde was formed due to the reaction between DPE and ozone. Further on-fiber derivatizations between pyriden-4-aldehyde and PFBHA were followed and the derivatives, oximes, were then determined by portable gas chromatography with electron capture detector. The experimental sampling rate of the SPME ozone passive sampler was found to be 1.10 x 10 -4 cm 3 s -1 with detection limit of 58.8 μg m -3 h -1 . Field validations with both SPME device and the direct-reading ozone monitor were also performed. The correlations between the results from both methods were found to be consistent with r = 0.9837. Compared with other methods, the current designed sampler provides a convenient and sensitive tool for the exposure assessments of ozone

  5. In situ derivatization-liquid liquid extraction as a sample preparation strategy for the determination of urinary biomarker prolyl-4-hydroxyproline by liquid chromatography-tandem mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Cimlová, Jana; Kružberská, Pavla; Švagera, Z.; Hušek, Petr; Šimek, Petr

    2012-01-01

    Roč. 47, č. 3 (2012), s. 294-302 ISSN 1076-5174 R&D Projects: GA ČR GA203/09/2014; GA MZd NS9755; GA MŠk 7F09028 Institutional research plan: CEZ:AV0Z50070508 Keywords : alkyl chloroformate derivatization * liquid liquid extraction * urine Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.214, year: 2012 http://onlinelibrary.wiley.com/doi/10.1002/jms.2952/full

  6. Immobilisation of ligands by radio-derivatized polymers

    International Nuclear Information System (INIS)

    Varga, J.M.; Fritsch, P.

    1995-01-01

    The invention relates to radio-derivatized polymers and a method of producing them by contacting non-polymerizable conjugands with radiolysable polymers in the presence of irradiation. The resulting radio-derivatized polymers can be further linked with ligand of organic or inorganic nature to immobilize such ligands. 2 figs., 5 tabs

  7. Bulk derivatization and direct injection of human cerebrospinal fluid for trace-level quantification of endogenous estrogens using trap-and-elute liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Fan, Hui; Papouskova, Barbora; Lemr, Karel; Wigginton, Jane G; Schug, Kevin A

    2014-08-01

    Although there are existing methods for determining estrogen in human bodily fluids including blood plasma and serum, very little information is available regarding estrogen levels in human cerebrospinal fluid (CSF), which is critical to assess in studies of neuroprotective functions and diffusion of neuroprotective estrogens across the blood-brain barrier. To address this problem, a liquid chromatography with tandem mass spectrometry method for the simultaneous quantification of four endogenous estrogens (estrone, 17α-estradiol, 17β-estradiol, and estriol) in human CSF was developed. An aliquot (300 μL) of human CSF was bulk derivatized using dansyl chloride in the sample and 10 μL was directly injected onto a restricted-access media trap column for protein removal. No off-line sample extraction or cleanup was needed. The limits of detection of estrone, 17α-estradiol, 17β-estradiol, and estriol were 17, 28, 13, and 30 pg/mL, respectively, which is in the parts-per-trillion regime. The method was then applied to human CSF collected from ischemic trauma patients. Endogenous estrogens were detected and quantified, demonstrating the effectiveness of this method. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. [Simultaneous determination of ten organotin compounds in polyvinyl chloride plastics using gas chromatography-mass spectrometry].

    Science.gov (United States)

    Li, Ying; Li, Bin; Liu, Li; Zhang, Chen; Wu, Jingwu; Liu, Zhihong; Li, Xintian

    2009-01-01

    A rapid and effective gas chromatography coupled with mass spectrometry method has been developed systematically and studied for the simultaneous determination of 10 organotin compounds, dibutyltin-dichloride (DBT), n-butyltin-trichloride (MBT), triethyltinchloride (TET), fentin-chloride (TPhT), chlorotributylstannane (TBT), tri-n-propyltinchloride (TPrT), diphenyltin-dichloride (DPhT), tetrabutyltin (TeBT), di-n-octyltin-dichloride (DOT), phenyltin trichloride (MPhT)), in polyvinyl chloride (PVC) plastics. The PVC sample was dissolved with tetrahydrofuran and the polymer in the sample was precipitated with methanol, and then the target compounds were derivatized with sodium tetraethylborate and extracted with hexane under ultrasonication. The qualitative and quantitative analysis were carried out by GC-MS and the total ion chromatogram and selected ion chromatogram were obtained. The derivatization and extraction conditions, such as the derivatization time, derivatization pH value, dosages of derivatization reagent and precipitation reagent were optimized. The good linearities, recoveries and precisions were obtained. The linearity ranges were 0.5 - 50 mg/L. The linearity correlation coefficients of 10 organotin compounds were between 0.997 8 and 0.999 7. The average recoveries were 84.23% - 109.1% with relative standard deviations of 4.24% - 10.75%. The established method has been successfully applied to the determination of organotin compounds in PVC plastics.

  9. Ambient Ionization Mass Spectrometry Measurement of Aminotransferase Activity

    Science.gov (United States)

    Yan, Xin; Li, Xin; Zhang, Chengsen; Xu, Yang; Cooks, R. Graham

    2017-06-01

    A change in enzyme activity has been used as a clinical biomarker for diagnosis and is useful in evaluating patient prognosis. Current laboratory measurements of enzyme activity involve multi-step derivatization of the reaction products followed by quantitative analysis of these derivatives. This study simplified the reaction systems by using only the target enzymatic reaction and directly detecting its product. A protocol using paper spray mass spectrometry for identifying and quantifying the reaction product has been developed. Evaluation of the activity of aspartate aminotransferase (AST) was chosen as a proof-of-principle. The volume of sample needed is greatly reduced compared with the traditional method. Paper spray has a desalting effect that avoids sprayer clogging problems seen when examining serum samples by nanoESI. This very simple method does not require sample pretreatment and additional derivatization reactions, yet it gives high quality kinetic data, excellent limits of detection (60 ppb from serum), and coefficients of variation <10% in quantitation. [Figure not available: see fulltext.

  10. High-performance liquid chromatographic determination of selenium in coal after derivatization to 2,1,3-benzoselenadiazoles

    Energy Technology Data Exchange (ETDEWEB)

    Khuhawar, M.Y.; Bozdar, R.B.; Babar, M.A. (Sindh University, Jamshoro (Pakistan). Inst. of Chemistry)

    1992-11-01

    High-performance liquid chromatography was examined for the determination of selenium after derivatization to 2,1,3-benzoselenadiazoles using 1,2-diaminobenzene, 1,2-diamino-4-nitrobenzene (NDAB), 2,3-diaminonaphthalene and 3,3-diaminobenzidine as derivatizing agents. Elution was carried out using a mixture of chloroform and hexane, with ultraviolet spectrophotometric detection. The 2,1,3-benzoselenadiazoles were extracted into toluene. Linear calibrations were obtained for 0-4[mu]g of selenium in 10 cm[sup 3] of solution and the detection limits were 20-50 ng of selenium in 10 cm[sup 3] of solution. The method was applied to the determination of selenium in coal samples and a shampoo using NDAB as the derivatizing reagent in acidic solution.

  11. [Simultaneous determination of glyphosate and glufosinate-ammonium residues in tea by ultra performance liquid chromatography-tandem mass spectrometry coupled with pre-column derivatization].

    Science.gov (United States)

    Wu, Xiaogang; Chen, Xiaoquan; Xiao, Haijun; Liu, Binqiu

    2015-10-01

    A method was developed for the determination of glyphosate (GLY) and glufosinate-ammonium (GLUF) in tea using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The sample was extracted with ultrapure water and dichloromethane for 30 min under ultrasonication, followed by a simple cleanup with a C18 solid phase extraction (SPE) cartridge, and then GLY and GLUF were derivatized using 9-fluorenylmethoxycarbonyl (FMOC-Cl) in borate buffer for 2 h. The derivatives of GLY and GLUF were separated on a Waters C18 column (50 mm x 2.1 mm, 1.7 μm) in a gradient elution mode, and finally detected with positive electrospray ionization-mass spectrometry (ESI-MS/MS ) in multiple reaction monitoring (MRM) mode. The quantification analysis was performed by external standard method. The method showed a good linearity (r > 0. 990) in the range of 0.003 125-0.1 mg/L. The limits of detection (LODs) of GLY and GLUF were 0.03 mg/kg. At the spiked levels of 0.375, 1.5 and 4.5 mg/kg, the recoveries of GLY and GLUF were 87.37%-99.11% and 81.44% -86.17% respectively, and the relative standard deviations (RSDs) (n = 6) of GLY and GLUF were 0.68%-1.35% and 1.01%-2.33%, respectively. This method is simple, rapid and characterized with acceptable sensitivity and accuracy to meet the requirements for the analysis of GLY and GLUF simultaneously in tea.

  12. Development of a Method for Rapid Determination of Morpholine in Juices and Drugs by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Mengsi Cao

    2018-01-01

    Full Text Available A reliable derivatization method has been developed to detect and quantify morpholine in apple juices and ibuprofen with gas chromatography-mass spectrometry. Morpholine can react with sodium nitrite under acidic condition to produce stable and volatile N-nitrosomorpholine derivative. In this experiment, various factors affecting the derivatization and extraction process were optimized, including volume and concentration of hydrochloric acid, quantity of sodium nitrite, derivatization temperature, derivatization time, extraction reagents, and extraction time. The derivative was extracted with dichloromethane and determined by gas chromatography-mass spectrometry. The linearity range of morpholine was 10–500 μg·L−1 with good correlation, and limits of detection (LOD and limits of quantification (LOQ were 7.3 μg·L−1 and 24.4 μg·L−1, respectively. Low, medium, and high concentrations of morpholine were added in apple juices and ibuprofen samples to evaluate standard recovery rate and relative standard deviation. The spiked recovery rate ranged from 94.3% to 109.0%, and the intraday repeatability and interday reproducibility were 2.0%–4.4% and 3.3%–7.0%, respectively. The developed method has good accuracy and precision. This quantitative method for morpholine is simple, sensitive, rapid, and low cost and can successfully be applied to analyze the residual morpholine in apple juices and drug samples.

  13. [Determination of five representative ultraviolet filters in water by gas chromatography-mass spectrometry].

    Science.gov (United States)

    Ding, Yiran; Huang, Yun; Zhao, Tingting; Cai, Qian; Luo, Yu; Huang, Bin; Zhang, Yuxia; Pan, Xuejun

    2014-06-01

    A method for the determination of five representative organic UV filters: ethylhexyl methoxycinnamate (EHMC), benzophenone-3 (BP-3), 4-methylbenzylidene camphor (4-MBC), octocrylene (OC), homosalate (HMS) in water was investigated. The method was ased on derivatization, solid phase extraction (SPE), followed by determination with gas chromatography-mass spectrometry (GC-MS). The variables involved in the derivatization of BP-3 and HMS were optimized, and SPE conditions were studied. For derivatization, 100 microL N,O-bis(trimethylsilyl) trifluoroacetamide (BSTFA) was used as derivatization reagent and reacted with BP-3 and HMS at 100 degrees C for 100 min. For SPE, the pH value of water sample was adjusted to 3-5. The Oasis HLB cartridges were employed and the solution of ethyl acetate and dichloromethane (1 : 1, v/v) was used as the eluting solvent, and good recoveries of the target compounds were obtained. The limits of detection (LODs) and the limits of quantification (LOQs) for the five target compounds in water samples were 0.5-1.2 ng/L and 1.4-4.0 ng/L, respectively. The recoveries of spiked water samples were 87.85%-102.34% with good repeatability and reproducibility (RSD < 5%, n = 3) for all the target compounds. Finally, the validated method was applied to analysis the representative UV filters in water samples collected from a wastewater treatment plant in Kunming city of Yunnan province.

  14. Precolumn derivatization LC–MS/MS method for the determination and pharmacokinetic study of glucosamine in human plasma and urine

    Directory of Open Access Journals (Sweden)

    Min Song

    2012-02-01

    Full Text Available A selective precolumn derivatization liquid chromatography–tandem mass spectrometric (LC–MS/MS method for the determination of glucosamine in human plasma and urine has been developed and validated. Glucosamine was derivatized by o-phthalaldehyde/3-mercaptopropionic acid. Chromatographic separation was performed on a Phenomenex ODS column (150 mm×4.6 mm, 5 μm using linear gradient elution by a mobile phase consisting of methanol (A, and an aqueous solution containing 0.2% ammonium acetate and 0.1% formic acid (B at a flow rate of 1 mL/min. Tolterodine tartrate was used as the internal standard (IS. With protein precipitation by acetonitrile and then the simple one-step derivatization, a sensitive bio-assay was achieved with the lower limit of quantitation (LLOQ as low as 12 ng/mL for plasma. The standard addition calibration curves suitable for clinical sample analysis showed good linearity over the range of 0.012–8.27 μg/mL in plasma and 1.80–84.1 μg/mL in urine. The fully validated method has been successfully applied to a pharmacokinetic study of compound glucosamine sulfate dispersible tablets in health Chinese volunteers receiving single oral doses at 500, 1000 and 1500 mg of glucosamine sulfate, as well as multiple oral doses of 500 mg t.i.d. for 7 consecutive days. Keywords: Glucosamine, Pharmacokinetics, Precolumn derivatization, LC–MS/MS

  15. Method for Derivatization and Detection of Chemical Weapons Convention Related Sulfur Chlorides via Electrophilic Addition with 3-Hexyne.

    Science.gov (United States)

    Goud, D Raghavender; Pardasani, Deepak; Purohit, Ajay Kumar; Tak, Vijay; Dubey, Devendra Kumar

    2015-07-07

    Sulfur monochloride (S2Cl2) and sulfur dichloride (SCl2) are important precursors of the extremely toxic chemical warfare agent sulfur mustard and classified, respectively, into schedule 3.B.12 and 3.B.13 of the Chemical Weapons Convention (CWC). Hence, their detection and identification is of vital importance for verification of CWC. These chemicals are difficult to detect directly using chromatographic techniques as they decompose and do not elute. Until now, the use of gas chromatographic approaches to follow the derivatized sulfur chlorides is not reported in the literature. The electrophilic addition reaction of sulfur monochloride and sulfur dichloride toward 3-hexyne was explored for the development of a novel derivatization protocol, and the products were subjected to gas chromatography-mass spectrometric (GC-MS) analysis. Among various unsaturated reagents like alkenes and alkynes, symmetrical alkyne 3-hexyne was optimized to be the suitable derivatizing agent for these analytes. Acetonitrile was found to be the suitable solvent for the derivatization reaction. The sample preparation protocol for the identification of these analytes from hexane spiked with petrol matrix was also optimized. Liquid-liquid extraction followed by derivatization was employed for the identification of these analytes from petrol matrix. Under the established conditions, the detection and quantification limits are 2.6 μg/mL, 8.6 μg/mL for S2Cl2 and 2.3 μg/mL, 7.7 μg/mL for SCl2, respectively, in selected ion monitoring (SIM) mode. The calibration curve had a linear relationship with y = 0.022x - 0.331 and r(2) = 0.992 for the working range of 10 to 500 μg/mL for S2Cl2 and y = 0.007x - 0.064 and r(2) = 0.991 for the working range of 10 to 100 μg/mL for SCl2, respectively. The intraday RSDs were between 4.80 to 6.41%, 2.73 to 6.44% and interday RSDs were between 2.20 to 7.25% and 2.34 to 5.95% for S2Cl2 and SCl2, respectively.

  16. Rapid determination of anti-estrogens by gas chromatography/mass spectrometry in urine: Method validation and application to real samples.

    Science.gov (United States)

    Gerace, E; Salomone, A; Abbadessa, G; Racca, S; Vincenti, M

    2012-02-01

    A fast screening protocol was developed for the simultaneous determination of nine anti-estrogenic agents (aminoglutethimide, anastrozole, clomiphene, drostanolone, formestane, letrozole, mesterolone, tamoxifen, testolactone) plus five of their metabolites in human urine. After an enzymatic hydrolysis, these compounds can be extracted simultaneously from urine with a simple liquid-liquid extraction at alkaline conditions. The analytes were subsequently analyzed by fast-gas chromatography/mass spectrometry (fast-GC/MS) after derivatization. The use of a short column, high-flow carrier gas velocity and fast temperature ramping produced an efficient separation of all analytes in about 4 min, allowing a processing rate of 10 samples/h. The present analytical method was validated according to UNI EN ISO/IEC 17025 guidelines for qualitative methods. The range of investigated parameters included the limit of detection, selectivity, linearity, repeatability, robustness and extraction efficiency. High MS-sampling rate, using a benchtop quadrupole mass analyzer, resulted in accurate peak shape definition under both scan and selected ion monitoring modes, and high sensitivity in the latter mode. Therefore, the performances of the method are comparable to the ones obtainable from traditional GC/MS analysis. The method was successfully tested on real samples arising from clinical treatments of hospitalized patients and could profitably be used for clinical studies on anti-estrogenic drug administration.

  17. Opsigtsvækkende nyt om derivater fra USA

    DEFF Research Database (Denmark)

    Thinggaard, Frank

    1997-01-01

    Der er opsigsvækkende nyt fra USA om den regnskabsmæssige behandling af derivater som terminskontrakter, futures, optioner, swaps m.v. Glem alt om historiske anskaffelsespriser. For derivater er der kun ét mål, som kan bruges: markedsværdier (fair-values). Glem alt om snakken om 'off-balance-sheet...

  18. Derivatization method of free cyanide including cyanogen chloride for the sensitive analysis of cyanide in chlorinated drinking water by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kang, Hye-In; Shin, Ho-Sang

    2015-01-20

    A novel derivatization method of free cyanide (HCN + CN(-)) including cyanogen chloride in chlorinated drinking water was developed with d-cysteine and hypochlorite. The optimum conditions (0.5 mM D-cysteine, 0.5 mM hypochlorite, pH 4.5, and a reaction time of 10 min at room temperature) were established by the variation of parameters. Cyanide (C(13)N(15)) was chosen as an internal standard. The formed β-thiocyanoalanine was directly injected into a liquid chromatography-tandem mass spectrometer without any additional extraction or purification procedures. Under the established conditions, the limits of detection and the limits of quantification were 0.07 and 0.2 μg/L, respectively, and the interday relative standard deviation was less than 4% at concentrations of 4.0, 20.0, and 100.0 μg/L. The method was successfully applied to determine CN(-) in chlorinated water samples. The detected concentration range and detection frequency of CN(-) were 0.20-8.42 μg/L (14/24) in source drinking water and 0.21-1.03 μg/L (18/24) in chlorinated drinking water.

  19. Extraction and derivatization of chemical weapons convention relevant aminoalcohols on magnetic cation-exchange resins.

    Science.gov (United States)

    Singh, Varoon; Garg, Prabhat; Chinthakindi, Sridhar; Tak, Vijay; Dubey, Devendra Kumar

    2014-02-14

    Analysis and identification of nitrogen containing aminoalcohols is an integral part of the verification analysis of chemical weapons convention (CWC). This study was aimed to develop extraction and derivatization of aminoalcohols of CWC relevance by using magnetic dispersive solid-phase extraction (MDSPE) in combination with on-resin derivatization (ORD). For this purpose, sulfonated magnetic cation-exchange resins (SMRs) were prepared using magnetite nanoparticles as core, styrene and divinylbenzene as polymer coat and sulfonic acid as acidic cation exchanger. SMRs were successfully employed as extractant for targeted basic analytes. Adsorbed analytes were derivatized with hexamethyldisilazane (HMDS) on the surface of extractant. Derivatized (silylated) compounds were analyzed by GC-MS in SIM and full scan mode. The linearity of the method ranged from 5 to 200ngmL(-1). The LOD and LOQ ranged from 2 to 6ngmL(-1) and 5 to 19ngmL(-1) respectively. The relative standard deviation for intra-day repeatability and inter-day intermediate precision ranged from 5.1% to 6.6% and 0.2% to 7.6% respectively. Recoveries of analytes from spiked water samples from different sources varied from 28.4% to 89.3%. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Spectrophotometric determination of metformin in pharmaceutical preparations, serum and urine using benzoin as derivatizing reagent

    International Nuclear Information System (INIS)

    Alamgir, M.; Hayat, A.

    2014-01-01

    A simple and selective spectrophotometric procedure is described for the determination of Metformin based on derivatization with benzoin. The Beers law was obeyed with 2.50-12.50 meu mol L-1 at 290 nm with coefficient of determination (r2) 0.997. The experimental conditions in term of pH, reaction time and temperature, and addition of derivatizing reagent were examined. The pure metformin-benzoin derivative was prepared and characterized by FT-IR and mass spectroscopic techniques. The method was applied for the determination of metformin from pharmaceutical preparations and serum and urine of volunteers after spiking with metformin. The results were checked by standard addition method. A number of pharmaceutical additives and serum or urine matrix did not affect the determination of metformin. (author)

  1. A sensitive and efficient method for trace analysis of some phenolic compounds using simultaneous derivatization and air-assisted liquid-liquid microextraction from human urine and plasma samples followed by gas chromatography-nitrogen phosphorous detection.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Afshar Mogaddam, Mohammad Reza; Alizadeh Nabil, Ali Akbar

    2015-12-01

    In present study, a simultaneous derivatization and air-assisted liquid-liquid microextraction method combined with gas chromatography-nitrogen phosphorous detection has been developed for the determination of some phenolic compounds in biological samples. The analytes are derivatized and extracted simultaneously by a fast reaction with 1-flouro-2,4-dinitrobenzene under mild conditions. Under optimal conditions low limits of detection in the range of 0.05-0.34 ng mL(-1) are achievable. The obtained extraction recoveries are between 84 and 97% and the relative standard deviations are less than 7.2% for intraday (n = 6) and interday (n = 4) precisions. The proposed method was demonstrated to be a simple and efficient method for the analysis of phenols in biological samples. Copyright © 2015 John Wiley & Sons, Ltd.

  2. Dual ultrasonic-assisted dispersive liquid-liquid microextraction coupled with microwave-assisted derivatization for simultaneous determination of 20(S)-protopanaxadiol and 20(S)-protopanaxatriol by ultra high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zhao, Xian-En; Lv, Tao; Zhu, Shuyun; Qu, Fei; Chen, Guang; He, Yongrui; Wei, Na; Li, Guoliang; Xia, Lian; Sun, Zhiwei; Zhang, Shijuan; You, Jinmao; Liu, Shu; Liu, Zhiqiang; Sun, Jing; Liu, Shuying

    2016-03-11

    This paper, for the first time, reported a speedy hyphenated technique of low toxic dual ultrasonic-assisted dispersive liquid-liquid microextraction (dual-UADLLME) coupled with microwave-assisted derivatization (MAD) for the simultaneous determination of 20(S)-protopanaxadiol (PPD) and 20(S)-protopanaxatriol (PPT). The developed method was based on ultra high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) detection using multiple-reaction monitoring (MRM) mode. A mass spectrometry sensitizing reagent, 4'-carboxy-substituted rosamine (CSR) with high reaction activity and ionization efficiency was synthesized and firstly used as derivatization reagent. Parameters of dual-UADLLME, MAD and UHPLC-MS/MS conditions were all optimized in detail. Low toxic brominated solvents were used as extractant instead of traditional chlorinated solvents. Satisfactory linearity, recovery, repeatability, accuracy and precision, absence of matrix effect and extremely low limits of detection (LODs, 0.010 and 0.015ng/mL for PPD and PPT, respectively) were achieved. The main advantages were rapid, sensitive and environmentally friendly, and exhibited high selectivity, accuracy and good matrix effect results. The proposed method was successfully applied to pharmacokinetics of PPD and PPT in rat plasma. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Detection of methamphetamine in the presence of nicotine using in situ chemical derivatization and ion mobility spectrometry.

    Science.gov (United States)

    Ochoa, Mariela L; Harrington, Peter B

    2004-02-15

    The detection of methamphetamine in the presence of nicotine has been successfully accomplished using in situ chemical derivatization with propyl chloroformate as the derivatization reagent and ion mobility spectrometry (IMS). The rapid detection of methamphetamine is important for forensic scientists in order to establish a chain of evidence and link criminals to the crime scene. Nicotine is pervasive in clandestine drug laboratories from cigarette smoke residue. It has been demonstrated that nicotine obscures the methamphetamine peaks in ion mobility spectrometers due to their similar charge affinities and ion mobilities, which makes their detection a challenging task. As a consequence, false positive or negative responses may arise. In situ chemical derivatization poses as a sensitive, accurate, and reproducible alternative to remove the nicotine background when detecting nanogram amounts of methamphetamine. The derivatization agent was coated onto the sample disk, and the derivatization product corresponding to propyl methamphetamine carbamate was detected. In the present study, in situ chemical derivatization was demonstrated to be a feasible method to detect methamphetamine hydrochloride as the carbamate derivative, which was baseline-resolved from the nicotine peak. Alternating least squares (ALS) was used to model the datasets. A mixture containing both compounds revealed reduced mobilities of 1.61 cm(2)/V.s and 1.54 cm(2)/V.s for methamphetamine and nicotine, respectively. The reduced mobility of propyl methamphetamine carbamate was found at 1.35 cm(2)/V.s.

  4. Determination of Glyphosate, its Degradation Product Aminomethylphosphonic Acid, and Glufosinate, in Water by Isotope Dilution and Online Solid-Phase Extraction and Liquid Chromatography/Tandem Mass Spectrometry

    Science.gov (United States)

    Meyer, Michael T.; Loftin, Keith A.; Lee, Edward A.; Hinshaw, Gary H.; Dietze, Julie E.; Scribner, Elisabeth A.

    2009-01-01

    The U.S. Geological Survey method (0-2141-09) presented is approved for the determination of glyphosate, its degradation product aminomethylphosphonic acid (AMPA), and glufosinate in water. It was was validated to demonstrate the method detection levels (MDL), compare isotope dilution to standard addition, and evaluate method and compound stability. The original method USGS analytical method 0-2136-01 was developed using liquid chromatography/mass spectrometry and quantitation by standard addition. Lower method detection levels and increased specificity were achieved in the modified method, 0-2141-09, by using liquid chromatography/tandem mass spectrometry (LC/MS/MS). The use of isotope dilution for glyphosate and AMPA and pseudo isotope dilution of glufosinate in place of standard addition was evaluated. Stable-isotope labeled AMPA and glyphosate were used as the isotope dilution standards. In addition, the stability of glyphosate and AMPA was studied in raw filtered and derivatized water samples. The stable-isotope labeled glyphosate and AMPA standards were added to each water sample and the samples then derivatized with 9-fluorenylmethylchloroformate. After derivatization, samples were concentrated using automated online solid-phase extraction (SPE) followed by elution in-line with the LC mobile phase; the compounds separated and then were analyzed by LC/MS/MS using electrospray ionization in negative-ion mode with multiple-reaction monitoring. The deprotonated derivatized parent molecule and two daughter-ion transition pairs were identified and optimized for glyphosate, AMPA, glufosinate, and the glyphosate and AMPA stable-isotope labeled internal standards. Quantitative comparison between standard addition and isotope dilution was conducted using 473 samples analyzed between April 2004 and June 2006. The mean percent difference and relative standard deviation between the two quantitation methods was 7.6 plus or minus 6.30 (n = 179), AMPA 9.6 plus or minus 8

  5. On-matrix derivatization extraction of chemical weapons convention relevant alcohols from soil.

    Science.gov (United States)

    Chinthakindi, Sridhar; Purohit, Ajay; Singh, Varoon; Dubey, D K; Pardasani, Deepak

    2013-10-11

    Present study deals with the on-matrix derivatization-extraction of aminoalcohols and thiodiglycols, which are important precursors and/or degradation products of VX analogues and vesicants class of chemical warfare agents (CWAs). The method involved hexamethyldisilazane (HMDS) mediated in situ silylation of analytes on the soil. Subsequent extraction and gas chromatography-mass spectrometry analysis of derivatized analytes offered better recoveries in comparison to the procedure recommended by the Organization for the Prohibition of Chemical Weapons (OPCW). Various experimental conditions such as extraction solvent, reagent and catalyst amount, reaction time and temperature were optimized. Best recoveries of analytes ranging from 45% to 103% were obtained with DCM solvent containing 5%, v/v HMDS and 0.01%, w/v iodine as catalyst. The limits of detection (LOD) and limit of quantification (LOQ) with selected analytes ranged from 8 to 277 and 21 to 665ngmL(-1), respectively, in selected ion monitoring mode. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Quantification of methionine and selenomethionine in biological samples using multiple reaction monitoring high performance liquid chromatography tandem mass spectrometry (MRM-HPLC-MS/MS).

    Science.gov (United States)

    Vu, Dai Long; Ranglová, Karolína; Hájek, Jan; Hrouzek, Pavel

    2018-05-01

    Quantification of selenated amino-acids currently relies on methods employing inductively coupled plasma mass spectrometry (ICP-MS). Although very accurate, these methods do not allow the simultaneous determination of standard amino-acids, hampering the comparison of the content of selenated versus non-selenated species such as methionine (Met) and selenomethionine (SeMet). This paper reports two approaches for the simultaneous quantification of Met and SeMet. In the first approach, standard enzymatic hydrolysis employing Protease XIV was applied for the preparation of samples. The second approach utilized methanesulfonic acid (MA) for the hydrolysis of samples, either in a reflux system or in a microwave oven, followed by derivatization with diethyl ethoxymethylenemalonate. The prepared samples were then analyzed by multiple reaction monitoring high performance liquid chromatography tandem mass spectrometry (MRM-HPLC-MS/MS). Both approaches provided platforms for the accurate determination of selenium/sulfur substitution rate in Met. Moreover the second approach also provided accurate simultaneous quantification of Met and SeMet with a low limit of detection, low limit of quantification and wide linearity range, comparable to the commonly used gas chromatography mass spectrometry (GC-MS) method or ICP-MS. The novel method was validated using certified reference material in conjunction with the GC-MS reference method. Copyright © 2018. Published by Elsevier B.V.

  7. Sample preparation techniques for the determination of natural 15N/14N variations in amino acids by gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS).

    Science.gov (United States)

    Hofmann, D; Gehre, M; Jung, K

    2003-09-01

    In order to identify natural nitrogen isotope variations of biologically important amino acids four derivatization reactions (t-butylmethylsilylation, esterification with subsequent trifluoroacetylation, acetylation and pivaloylation) were tested with standard mixtures of 17 proteinogenic amino acids and plant (moss) samples using GC-C-IRMS. The possible fractionation of the nitrogen isotopes, caused for instance by the formation of multiple reaction products, was investigated. For biological samples, the esterification of the amino acids with subsequent trifluoroacetylation is recommended for nitrogen isotope ratio analysis. A sample preparation technique is described for the isotope ratio mass spectrometric analysis of amino acids from the non-protein (NPN) fraction of terrestrial moss. 14N/15N ratios from moss (Scleropodium spec.) samples from different anthropogenically polluted areas were studied with respect to ecotoxicologal bioindication.

  8. Combined derivatization and high-performance liquid chromatography with fluorescence and ultraviolet detection for simultaneous analysis of octreotide and gabexate mesylate metabolite in human pancreatic juice samples.

    Science.gov (United States)

    Carlucci, Giuseppe; Selvaggi, Federico; Sulpizio, Sara; Bassi, Claudio; Carlucci, Maura; Cotellese, Roberto; Ferrone, Vincenzo; Innocenti, Paolo; Locatelli, Marcello

    2015-06-01

    A simple and sensitive method based on the combination of derivatization and high-performance liquid chromatography with ultraviolet and fluorimetric detection was developed for the simultaneous determination of octreotide and gabexate mesylate metabolite in human pancreatic juice samples. Parameters of the derivatization procedure affecting extraction efficiency were optimized. The developed method was validated according to the International Conference on Harmonization guidelines. The calibration curves were linear over a range of 0.1-15 µg/mL for octreotide and 0.20-15 µg/mL for gabexate mesylate metabolite. Derivatized products of octreotide and gabexate mesylate metabolite were separated on a Luna C18 column (4.6 × 250 mm; 5 µm particle size) using a gradient with a run time of 36 min, without further purification. The limits of detection were 0.025 and 0.05, respectively, for octreotide and gabexate mesylate metabolite. This paper reports the validation of a quantitative high performance liquid chromatography-photodiode array-fluorescence (HPLC-PDA-FL) method for the simultaneous analysis of octreotide and gabexate mesylate metabolite in pancreatic juice by protein precipitation using zinc sulfate-methanol-acetonitrile containing the derivatizing reagent, 4-fluoro-7-nitro-[2,1,3]-benzoxadiazole (NBD-F). Derivatized products of octreotide and gabexate mesylate metabolite were separated on a Luna C18 column (4.6 × 250 mm; 5 µm particle size) using a gradient with a run time of 36 min, without further purification. The method was validated over the concentration ranges 0.1-15 and 0.2-15 µg/mL for octreotide and gabexate mesylate metabolite, respectively, in human pancreatic juice. Biphalin and methyl-p-hydroxybenzoate were used as the internal standards. This method was successfully utilized to support clinical studies in humans. The results from assay validations show that the method is selective, sensitive and robust. The limit

  9. Derivatization, characterization, and tribological behavior of an amine-terminated polymer surface

    International Nuclear Information System (INIS)

    Ren, S.L.; Yang, S.R.; Zhao, Y.P.

    2004-01-01

    The derivatization, characterization, and micro-tribological behavior of an amine-terminated polymer surface were investigated. Thus, the heptafluorobutyric anhydride (HFBA) derivatized film was characterized by means of contact-angle measurement and X-ray photoelectron spectroscopy (XPS). It was found that the HFBA-derivatized film was generated on the PEI surface in the presence of a chemical amide bond. The tribological properties were characterized as well. The polymer PEI film had relative high adhesion, friction, and poor anti-wear ability, while the HFBA-derivatized polymer film possessed a very low adhesive force of only about 5.5 nN (a pyramidal Si 3 N 4 tip with radius of curvature about 50 nm was used to measure the adhesion), which was more than an order of magnitude lower than that of the silicon substrate surface. Besides, the HFBA-derivatized film registered good friction-reducing ability and thermal stability. Thus, a good alternative method was presented to improve the tribological properties of polymer film by chemisorbing molecules with low surface energy. This makes it feasible for the derivatized polymer film to find promising application in resolving the tribological problems of micro-electromechanical systems (MEMS)

  10. Determination of organoarsenicals in the environment by solid-phase microextraction-gas chromatography-mass spectrometry.

    Energy Technology Data Exchange (ETDEWEB)

    Szostek, B.; Aldstadt, J. H.; Environmental Research

    1998-05-22

    The development of a method for the analysis of organoarsenic compounds that combines dithiol derivatization with solid-phase microextraction (SPME) sample preparation and gas chromatography-mass spectrometry (GC-MS) is described. Optimization focused on a SPME-GC-MS procedure for determination of 2-chlorovinylarsonous acid (CVAA), the primary decomposition product of the chemical warfare agent known as Lewisite. Two other organoarsenic compounds of environmental interest, dimethylarsinic acid and phenylarsonic acid, were also studied. A series of dithiol compounds was examined for derivatization of the arsenicals, and the best results were obtained either with 1,3-propanedithiol or 1,2-ethanedithiol. The derivatization procedure, fiber type, and extraction time were optimized. For CVAA, calibration curves were linear over three orders of magnitude and limits-of-detection were <6x10{sup -9} M in solution, the latter a more than 400x improvement compared to conventional solvent extraction GC-MS methods. A precision of <10% R.S.D. was typical for the SPME-GC-MS procedure. The method was applied to a series of water samples and soil/sediment extracts, as well as to aged soil samples that had been contaminated with Lewisite.

  11. Developing a New Sampling And Analysis Method For Hydrazine And Monomethyl Hydrazine: Using a Derivatizing Agent With Solid Phase Microextraction

    Science.gov (United States)

    Allen, John

    2001-01-01

    Solid phase microextraction (SPME) will be used to develop a method for detecting monomethyl hydrazine (MMH) and hydrazine (Hz). A derivatizing agent, pentafluorobenzoyl chloride (PFBCI), is known to react readily with MMH and Hz. The SPME fiber can either be coated with PFBCl and introduced into a gaseous stream containing MMH, or PFBCl and MMH can react first in a syringe barrel and after a short equilibration period a SPME is used to sample the resulting solution. These methods were optimized and compared. Because Hz and MMH can degrade the SPME, letting the reaction occur first gave better results. Only MMH could be detected using either of these methods. Future research will concentrate on constructing calibration curves and determining the detection limit.

  12. A denuder-impinger system with in situ derivatization followed by gas chromatography-mass spectrometry for the determination of gaseous iodine-containing halogen species.

    Science.gov (United States)

    Huang, Ru-Jin; Hoffmann, Thorsten

    2008-11-14

    Reactive iodine species have been suggested to play an important role in the atmosphere (e.g. tropospheric ozone depletion, coastal new particle formation). However, there still exist major uncertainties about their atmospheric chemistry, mostly due to the lack of analytical approaches for the accurate speciation of certain key compounds. In this study, 1,3,5-trimethoxybenzene (1,3,5-TMB)-coated denuder proved to be suitable for the differentiation between gaseous interhalogens (iodine monochloride (ICl), iodine monobromide (IBr)) and molecular iodine (I2) based on a selective collection/derivatization method. The results of the denuder sampling were compared with the results of impinger sampling in water, methanol and carbon tetrachloride solutions of 1,3,5-TMB. ICl and IBr are converted into 1-iodo-2,4,6-trimethoxybenzene (1-iodo-2,4,6-TMB) and 1-bromo-2,4,6-trimethoxybenzene (1-bromo-2,4,6-TMB), respectively, in the denuder systems. The respective collection efficiency is 99.2% for ICl and 92.6% for IBr, at 500mLmin(-1) gas flow rate. The collection efficiency for I2 is lower than 1% in the same denuder system, but significantly increases to about 90% in the aqueous 1,3,5-TMB loaded impinger. The denuder-impinger coupled system was then used to differentiate and to collect the ICl, IBr and I2 gas mixtures, followed by gas chromatography-ion trap mass spectrometry (GC-MS) determination. The precision of the method is in general better than 9.1%. The parameters affecting denuder operation including sampling flow rate, sampling duration, and relative humidity have been evaluated. The presented method provides an attractive protocol for iodine species analysis for atmospheric chemistry research.

  13. Determination of glufosinate ammonium and its metabolite (AE F064619 and AE F061517) residues in water by gas chromatography with tandem mass spectrometry after ion exchange cleanup and derivatization.

    Science.gov (United States)

    Royer, A; Beguin, S; Sochor, H; Communal, P Y

    2000-11-01

    An analytical method for the determination of glufosinate ammonium and its principal metabolites, AE F064619 and AE F061517, in water of two different hardnesses (5 and 30 DH, French hardness) has been developed and validated. Samples were spiked at different levels (0. 05 and 0.5 microgram/L) and were purified by column chromatography on ion-exchange resins. After derivatization with glacial acetic acid and trimethylarthoacetate mixture, the derivatives were quantified by using capillary gas chromatography with an ion-trap tandem mass spectrometric detector. Analytical conditions for MS/MS detection were optimized, and the quantification was carried out on the areas of the most representative ions. The limit of quantification was validated at 0.05 microgram/L for each compound. The mean recovery value and the relative standard deviation (n = 20) were 92.0% and 17. 8% for glufosinate ammonium, 90.2% and 15.8% for AE F064619, and 89. 7% and 12.7% for AE F061517.

  14. Process for derivatizing carbon nanotubes with diazonium species

    Science.gov (United States)

    Tour, James M. (Inventor); Bahr, Jeffrey L. (Inventor); Yang, Jiping (Inventor)

    2007-01-01

    The invention incorporates new processes for the chemical modification of carbon nanotubes. Such processes involve the derivatization of multi- and single-wall carbon nanotubes, including small diameter (ca. 0.7 nm) single-wall carbon nanotubes, with diazonium species. The method allows the chemical attachment of a variety of organic compounds to the side and ends of carbon nanotubes. These chemically modified nanotubes have applications in polymer composite materials, molecular electronic applications and sensor devices. The methods of derivatization include electrochemical induced reactions thermally induced reactions (via in-situ generation of diazonium compounds or pre-formed diazonium compounds), and photochemically induced reactions. The derivatization causes significant changes in the spectroscopic properties of the nanotubes. The estimated degree of functionality is ca. 1 out of every 20 to 30 carbons in a nanotube bearing a functionality moiety. Such electrochemical reduction processes can be adapted to apply site-selective chemical functionalization of nanotubes. Moreover, when modified with suitable chemical groups, the derivatized nanotubes are chemically compatible with a polymer matrix, allowing transfer of the properties of the nanotubes (such as, mechanical strength or electrical conductivity) to the properties of the composite material as a whole. Furthermore, when modified with suitable chemical groups, the groups can be polymerized to form a polymer that includes carbon nanotubes ##STR00001##.

  15. Determining the fatty acid composition in plasma and tissues as fatty acid methyl esters using gas chromatography – a comparison of different derivatization and extraction procedures.

    Science.gov (United States)

    Ostermann, Annika I; Müller, Maike; Willenberg, Ina; Schebb, Nils Helge

    2014-12-01

    Analysis of the fatty acid (FA) composition in biological samples is commonly carried out using gas liquid chromatography (GC) after transesterification to volatile FA methyl esters (FAME). We compared the efficacy of six frequently used protocols for derivatization of different lipid classes as well as for plasma and tissue samples. Transesterification with trimethylsulfonium hydroxide (TMSH) led to insufficient derivatization efficacies for polyunsaturated FAs (PUFA, ester (CE) as well as triacylglycerols (TGs). In contrast, methanolic hydrochloric acid (HCl) as well as a combination of BF3 with methanolic sodium hydroxide (NaOH+BF3) were suitable for the derivatization of FFAs, polar lipids, TGs, and CEs (derivatization rate >80% for all tested lipids). Regarding plasma samples, all methods led to an overall similar relative FA pattern. However, significant differences were observed, for example, for the relative amount of EPA+DHA (n3-index). Absolute FA plasma concentrations differed considerably among the methods, with low yields for KOH and BF3. We also demonstrate that lipid extraction with tert-butyl methyl ether/methanol (MTBE/MeOH) is as efficient as the classical method according to Bligh and Dyer, making it possible to replace (environmentally) toxic chloroform.We conclude that HCl-catalyzed derivatization in combination with MeOH/MTBE extraction is the most appropriate among the methods tested for the analysis of FA concentrations and FA pattern in small biological samples. A detailed protocol for the analysis of plasma and tissues is included in this article.

  16. Simultaneous derivatization and lighter-than-water air-assisted liquid-liquid microextraction using a homemade device for the extraction and preconcentration of some parabens in different samples.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Aghdam, Mehri Bakhshizadeh; Mogaddam, Mohammad Reza Afshar; Nabil, Ali Akbar Alizadeh

    2018-06-06

    Simultaneous derivatization and air-assisted liquid-liquid microextraction using an organic solvent lighter than water has been developed for the extraction of some parabens in different samples with the aid of a newly designed device for collecting the extractant. For this purpose, the sample solution is transferred into a glass test tube and a few microliters of acetic anhydride (as a derivatization agent) and p-xylene (as an extraction solvent) are added to the solution. After performing the procedure, the homemade device consists of an inverse funnel with a capillary tube placed into the tube. In this step, the collected extraction solvent and a part of the aqueous solution are transferred into the device and the organic phase indwells in the capillary tube of the device. Under the optimal conditions, limits of detection and quantification for the analytes were obtained in the ranges of 0.90-2.7 and 3.0-6.1 ng mL -1 , respectively. The enrichment and enhancement factors were in the ranges of 370-430 and 489-660, respectively. The method precision, expressed as the relative standard deviation, was within the ranges of 4-6% (n = 6) and 4-9% (n = 4) for intra- and inter-day precisions, respectively. The proposed method was successfully used for the determination of methyl-, ethyl-, and propyl parabens in cosmetic, hygiene, and food samples, and personal care products. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  17. Analysis of Phenolic and Cyclic Compounds in Plants Using Derivatization Techniques in Combination with GC-MS-Based Metabolite Profiling

    Directory of Open Access Journals (Sweden)

    Jens Rohloff

    2015-02-01

    Full Text Available Metabolite profiling has been established as a modern technology platform for the description of complex chemical matrices and compound identification in biological samples. Gas chromatography coupled with mass spectrometry (GC-MS in particular is a fast and accurate method widely applied in diagnostics, functional genomics and for screening purposes. Following solvent extraction and derivatization, hundreds of metabolites from different chemical groups can be characterized in one analytical run. Besides sugars, acids, and polyols, diverse phenolic and other cyclic metabolites can be efficiently detected by metabolite profiling. The review describes own results from plant research to exemplify the applicability of GC-MS profiling and concurrent detection and identification of phenolics and other cyclic structures.

  18. APPLICATION OF DNPH DERIVATIZATION WITH LC/MS TO THE IDENTIFICATION OF POLAR CARBONYL DRINKING WATER DISINFECTION BY-PRODUCTS IN DRINKING WATER

    Science.gov (United States)

    A qualitative method using 2,4-dinitrophenylhydrazine (DNPH) derivatization followed by analysis with liquid chromatography (LC)/negative ion-electrospray mass spectrometry (MS) was developed for analyzing and identifying highly polar aldehydes and ketones in ozonated drinking wa...

  19. Automated precolumn derivatization procedures in HPLC for biomedical and clinical applications

    NARCIS (Netherlands)

    Wolf, Johannes Hendrik

    1992-01-01

    This thesis describes three automated precolumn derivatization procedures for the analysis of carboxylic group-containing compounds. After derivatization with a suitable label, the derivatives are separated on reversed-phashed HPLC and detected by fluorescence. ... Zie: Summary

  20. The competition of charge remote and charge directed fragmentation mechanisms in quaternary ammonium salt derivatized peptides--an isotopic exchange study.

    Science.gov (United States)

    Cydzik, Marzena; Rudowska, Magdalena; Stefanowicz, Piotr; Szewczuk, Zbigniew

    2011-12-01

    Derivatization of peptides as quaternary ammonium salts (QAS) is a promising method for sensitive detection by electrospray ionization tandem mass spectrometry (Cydzik et al. J. Pept. Sci. 2011, 17, 445-453). The peptides derivatized by QAS at their N-termini undergo fragmentation according to the two competing mechanisms - charge remote (ChR) and charge directed (ChD). The absence of mobile proton in the quaternary salt ion results in ChR dissociation of a peptide bond. However, Hofmann elimination of quaternary salt creates an ion with one mobile proton leading to the ChD fragmentation. The experiments on the quaternary ammonium salts with deuterated N-alkyl groups or amide NH bonds revealed that QAS derivatized peptides dissociate according to the mixed ChR-ChD mechanism. The isotopic labeling allows differentiation of fragments formed according to ChR and ChD mechanisms. © The Author(s) 2011. This article is published with open access at Springerlink.com

  1. Quantification of 4-hydroxy-2,5-dimethyl-3-furanone in fruit samples using solid phase microextraction coupled with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Chen, Yong; Sidisky, Leonard M

    2011-09-23

    Furaneol is an important aroma compound. It is very difficult to extract furaneol from food matrices and separate it on a gas chromatography column due to its high polarity and instability. A new quantitative method was developed to quantify furaneol in aqueous samples by the use of derivatization/solid phase microextraction (SPME) coupled with gas chromatography/mass spectrometry (GC/MS). The derivatization was carried out by reacting pentafluorobenzyl bromide with furaneol in basic solutions at elevated temperatures. The derivative was stable and less polar so that SPME-GC/MS could be applied for extraction, separation and detection. The automated analytical method had a limit of detection (LOD) of 0.5 ng mL(-1), a limit of quantification (LOQ) of 2 ng mL(-1), a repeatability of 9.5%, and a linear range from 2 to 500 ng mL(-1). The method was applied to analyze fruit samples. And it was found that the concentrations of furaneol in tomato ranged from 95 to 173 μg kg(-1), in strawberries ranged from 1663 to 4852 μg kg(-1). The results were verified with a LC procedure. To facilitate analytical method development, some physico-chemical parameters for furaneol were determined in this work. Its solubility in water was determined as 0.315 g mL(-1) (25°C). Its LogD in water and LogP in 0.1 M phosphate buffer were -0.133 and 0.95 (20 °C), respectively. Its pKa was 8.56 (20 °C). Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Organic acid derivatization techniques applied to petroleum hydrocarbon transformations in subsurface environments

    International Nuclear Information System (INIS)

    Barcelona, M.J.; Lu, J.; Tomczak, D.M.

    1995-01-01

    Evidence for the natural microbial remediation of subsurface fuel contamination situations should include identification and analysis of transformation or degradation products. In this way, a mass balance between fuel constituents and end products may be approached to monitor cleanup progress. Application of advanced organic acid metabolite derivatization techniques to several know sites of organic compounds and fuel mixture contamination provide valuable information on the pathways and progress of microbial transformation. Good correlation between observed metabolites and transformation pathways of aromatic fuel constituents were observed at the sites

  3. Trace analysis of icariin in human serum with dansyl chloride derivatization after oral administration of Epimedium decoction by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Gong, Yinhan; Yip, See Chung; Thamarai, Sennappan Kanagamani; Zhang, Jie; Lee, Hian Kee; Yong, E L

    2007-12-15

    Epimedium herbs are a type of complex traditional Chinese medicine (TCM) with high estrogenic bioactivity. The Epimedium herbal decoction mixture contains many compounds including icariin that can exert potent effects on numerous physiological processes related to human health. An ultrasensitive liquid chromatography tandem mass spectrometric (LC-MS/MS) method has been developed to determine trace levels of icariin in human serum with dansyl chloride derivatization after oral administration of the Epimedium herbal decoctions. The dansyl-icariin showed an intense protonated molecular ion at m/z 910. The collision-induced dissociation of this ion formed a distinctive product at m/z 764, corresponding to a characteristic removal of a rhamnose sugar moiety of icariin. The selected reaction monitoring, based on the m/z 910-->764 transition, was highly specific and ultrasenstive for icariin in human serum samples. The lower limit of quantitation was 10 pg/mL icariin spiked into blank serum. The ranges of coefficients of variation for interday assays and intraday assays were 0-15.0% and 1.1-17.5%, respectively, for a wide linear range from 10 pg/mL to 4 ng/mL. This method was successfully applied to measure trace levels of icariin in a human serum after oral administration of Epimedium decoction within 48 h for the first time.

  4. An isotope-labeled chemical derivatization method for the quantitation of short-chain fatty acids in human feces by liquid chromatography–tandem mass spectrometry

    International Nuclear Information System (INIS)

    Han, Jun; Lin, Karen; Sequeira, Carita; Borchers, Christoph H.

    2015-01-01

    Highlights: • 3-Nitrophenylhydrazine was used to derivatize short-chain fatty acids (SCFAs) for LC-MS/MS. • 13 C 6 analogues were produced for use as isotope-labeled internal standards. • Isotope-labeled standards compensate for ESI matrix effects in LC-MS/MS. • Femtomolar sensitivities and 93–108% quantitation accuracy were achieved for human fecal SCFAs. - Abstract: Short-chain fatty acids (SCFAs) are produced by anaerobic gut microbiota in the large bowel. Qualitative and quantitative measurements of SCFAs in the intestinal tract and the fecal samples are important to understand the complex interplay between diet, gut microbiota and host metabolism homeostasis. To develop a new LC-MS/MS method for sensitive and reliable analysis of SCFAs in human fecal samples, 3-nitrophenylhydrazine (3NPH) was employed for pre-analytical derivatization to convert ten C 2 –C 6 SCFAs to their 3-nitrophenylhydrazones under a single set of optimized reaction conditions and without the need of reaction quenching. The derivatives showed excellent in-solution chemical stability. They were separated on a reversed-phase C 18 column and quantitated by negative-ion electrospray ionization – multiple-reaction monitoring (MRM)/MS. To achieve accurate quantitation, the stable isotope-labeled versions of the derivatives were synthesized in a single reaction vessel from 13 C 6 -3NPH, and were used as internal standard to compensate for the matrix effects in ESI. Method validation showed on-column limits of detection and quantitation over the range from low to high femtomoles for the ten SCFAs, and the intra-day and inter-day precision for determination of nine of the ten SCFAs in human fecal samples was ≤8.8% (n = 6). The quantitation accuracy ranged from 93.1% to 108.4% (CVs ≤ 4.6%, n = 6). This method was used to determine the SCFA concentrations and compositions in six human fecal samples. One of the six samples, which was collected from a clinically diagnosed type 2

  5. An isotope-labeled chemical derivatization method for the quantitation of short-chain fatty acids in human feces by liquid chromatography–tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Han, Jun; Lin, Karen; Sequeira, Carita [University of Victoria – Genome BC Proteomics Centre, University of Victoria, Vancouver Island Technology Park, 3101–4464 Markham Street, Victoria, BC V8Z 7X8 (Canada); Borchers, Christoph H., E-mail: christoph@proteincentre.com [University of Victoria – Genome BC Proteomics Centre, University of Victoria, Vancouver Island Technology Park, 3101–4464 Markham Street, Victoria, BC V8Z 7X8 (Canada); Department of Biochemistry and Microbiology, University of Victoria, Petch Building Room 207, 3800 Finnerty Road, Victoria, BC V8P 5C2 (Canada)

    2015-01-07

    Highlights: • 3-Nitrophenylhydrazine was used to derivatize short-chain fatty acids (SCFAs) for LC-MS/MS. • {sup 13}C{sub 6} analogues were produced for use as isotope-labeled internal standards. • Isotope-labeled standards compensate for ESI matrix effects in LC-MS/MS. • Femtomolar sensitivities and 93–108% quantitation accuracy were achieved for human fecal SCFAs. - Abstract: Short-chain fatty acids (SCFAs) are produced by anaerobic gut microbiota in the large bowel. Qualitative and quantitative measurements of SCFAs in the intestinal tract and the fecal samples are important to understand the complex interplay between diet, gut microbiota and host metabolism homeostasis. To develop a new LC-MS/MS method for sensitive and reliable analysis of SCFAs in human fecal samples, 3-nitrophenylhydrazine (3NPH) was employed for pre-analytical derivatization to convert ten C{sub 2}–C{sub 6} SCFAs to their 3-nitrophenylhydrazones under a single set of optimized reaction conditions and without the need of reaction quenching. The derivatives showed excellent in-solution chemical stability. They were separated on a reversed-phase C{sub 18} column and quantitated by negative-ion electrospray ionization – multiple-reaction monitoring (MRM)/MS. To achieve accurate quantitation, the stable isotope-labeled versions of the derivatives were synthesized in a single reaction vessel from {sup 13}C{sub 6}-3NPH, and were used as internal standard to compensate for the matrix effects in ESI. Method validation showed on-column limits of detection and quantitation over the range from low to high femtomoles for the ten SCFAs, and the intra-day and inter-day precision for determination of nine of the ten SCFAs in human fecal samples was ≤8.8% (n = 6). The quantitation accuracy ranged from 93.1% to 108.4% (CVs ≤ 4.6%, n = 6). This method was used to determine the SCFA concentrations and compositions in six human fecal samples. One of the six samples, which was collected from a

  6. Liquid chromatography coupled to on-line post column derivatization for the determination of organic compounds: A review on instrumentation and chemistries

    International Nuclear Information System (INIS)

    Zacharis, Constantinos K.; Tzanavaras, Paraskevas D.

    2013-01-01

    Graphical abstract: -- Highlights: •Review on liquid chromatography coupled to post-column derivatization. •Overview of instrumentation for post-column derivatization. •Post-column chemistries for analysis of organic compounds. -- Abstract: Analytical derivatization either in pre or post column modes is one of the most widely used sample pretreatment techniques coupled to liquid chromatography. In the present review article we selected to discuss the post column derivatization mode for the analysis of organic compounds. The first part of the review focuses to the instrumentation of post-column setups including not only fundamental components such as pumps and reactors but also less common parts such as static mixers and back-pressure regulators; the second part of the article discusses the most popular “chemistries” that are involved in post column applications, including reagent-less approaches and new sensing platforms such as the popular gold nanoparticles. Some representative recent applications are also presented as tables

  7. Liquid chromatography coupled to on-line post column derivatization for the determination of organic compounds: A review on instrumentation and chemistries

    Energy Technology Data Exchange (ETDEWEB)

    Zacharis, Constantinos K., E-mail: zacharis@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotelian University of Thessaloniki, GR-54124 Thessaloniki (Greece); Department of Food Technology, School of Food Technology and Nutrition, Alexander Technological Educational Institute (ATEI) of Thessaloniki, 57400 Thessaloniki (Greece); Tzanavaras, Paraskevas D., E-mail: ptzanava@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotelian University of Thessaloniki, GR-54124 Thessaloniki (Greece)

    2013-10-10

    Graphical abstract: -- Highlights: •Review on liquid chromatography coupled to post-column derivatization. •Overview of instrumentation for post-column derivatization. •Post-column chemistries for analysis of organic compounds. -- Abstract: Analytical derivatization either in pre or post column modes is one of the most widely used sample pretreatment techniques coupled to liquid chromatography. In the present review article we selected to discuss the post column derivatization mode for the analysis of organic compounds. The first part of the review focuses to the instrumentation of post-column setups including not only fundamental components such as pumps and reactors but also less common parts such as static mixers and back-pressure regulators; the second part of the article discusses the most popular “chemistries” that are involved in post column applications, including reagent-less approaches and new sensing platforms such as the popular gold nanoparticles. Some representative recent applications are also presented as tables.

  8. Dual element ((15)N/(14)N, (13)C/(12)C) isotope analysis of glyphosate and AMPA by derivatization-gas chromatography isotope ratio mass spectrometry (GC/IRMS) combined with LC/IRMS.

    Science.gov (United States)

    Mogusu, Emmanuel O; Wolbert, J Benjamin; Kujawinski, Dorothea M; Jochmann, Maik A; Elsner, Martin

    2015-07-01

    To assess sources and degradation of the herbicide glyphosate [N-(phosphonomethyl) glycine] and its metabolite AMPA (aminomethylphosphonic acid), concentration measurements are often inconclusive and even (13)C/(12)C analysis alone may give limited information. To advance isotope ratio analysis of an additional element, we present compound-specific (15)N/(14)N analysis of glyphosate and AMPA by a two step derivatization in combination with gas chromatography/isotope ratio mass spectrometry (GC/IRMS). The N-H group was derivatized with isopropyl chloroformate (iso-PCF), and remaining acidic groups were subsequently methylated with trimethylsilyldiazomethane (TMSD). Iso-PCF treatment at pH 10 indicated decomposition of the derivative. At pH 10, and with an excess of iso-PCF by 10-24, greatest yields and accurate (15)N/(14)N ratios were obtained (deviation from elemental analyzer-IRMS: -0.2 ± 0.9% for glyphosate; -0.4 ± 0.7% for AMPA). Limits for accurate δ(15)N analysis of glyphosate and AMPA were 150 and 250 ng injected, respectively. A combination of δ(15)N and δ(13)C analysis by liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) (1) enabled an improved distinction of commercial glyphosate products and (2) showed that glyphosate isotope values during degradation by MnO2 clearly fell outside the commercial product range. This highlights the potential of combined carbon and nitrogen isotopes analysis to trace sources and degradation of glyphosate.

  9. Quantitative analysis of phytosterols in edible oils using APCI liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    Mo, Shunyan; Dong, Linlin; Hurst, W. Jeffrey; van Breemen, Richard B.

    2014-01-01

    Previous methods for the quantitative analysis of phytosterols have usually used GC-MS and require elaborate sample preparation including chemical derivatization. Other common methods such as HPLC with absorbance detection do not provide information regarding the identity of the analytes. To address the need for an assay that utilizes mass selectivity while avoiding derivatization, a quantitative method based on LC-tandem mass spectrometry (LC-MS-MS) was developed and validated for the measurement of six abundant dietary phytosterols and structurally related triterpene alcohols including brassicasterol, campesterol, cycloartenol, β-sitosterol, stigmasterol, and lupeol in edible oils. Samples were saponified, extracted with hexane and then analyzed using reversed phase HPLC with positive ion atmospheric pressure chemical ionization tandem mass spectrometry and selected reaction monitoring. The utility of the LC-MS-MS method was demonstrated by analyzing 14 edible oils. All six compounds were present in at least some of the edible oils. The most abundant phytosterol in all samples was β-sitosterol, which was highest in corn oil at 4.35 ± 0.03 mg/g, followed by campesterol in canola oil at 1.84 ± 0.01 mg/g. The new LC-MS-MS method for the quantitative analysis of phytosterols provides a combination of speed, selectivity and sensitivity that exceed those of previous assays. PMID:23884629

  10. Rapid determination of anti-estrogens by gas chromatography/mass spectrometry in urine: Method validation and application to real samples

    Directory of Open Access Journals (Sweden)

    E. Gerace

    2012-02-01

    Full Text Available A fast screening protocol was developed for the simultaneous determination of nine anti-estrogenic agents (aminoglutethimide, anastrozole, clomiphene, drostanolone, formestane, letrozole, mesterolone, tamoxifen, testolactone plus five of their metabolites in human urine. After an enzymatic hydrolysis, these compounds can be extracted simultaneously from urine with a simple liquid–liquid extraction at alkaline conditions. The analytes were subsequently analyzed by fast-gas chromatography/mass spectrometry (fast-GC/MS after derivatization. The use of a short column, high-flow carrier gas velocity and fast temperature ramping produced an efficient separation of all analytes in about 4 min, allowing a processing rate of 10 samples/h. The present analytical method was validated according to UNI EN ISO/IEC 17025 guidelines for qualitative methods. The range of investigated parameters included the limit of detection, selectivity, linearity, repeatability, robustness and extraction efficiency. High MS-sampling rate, using a benchtop quadrupole mass analyzer, resulted in accurate peak shape definition under both scan and selected ion monitoring modes, and high sensitivity in the latter mode. Therefore, the performances of the method are comparable to the ones obtainable from traditional GC/MS analysis. The method was successfully tested on real samples arising from clinical treatments of hospitalized patients and could profitably be used for clinical studies on anti-estrogenic drug administration. Keywords: Anti-estrogens, Fast-GC/MS, Urine screening, Validation, Breast cancer

  11. Simultaneous in situ derivatization and ultrasound-assisted dispersive magnetic solid phase extraction for thiamine determination by spectrofluorimetry.

    Science.gov (United States)

    Tarigh, Ghazale Daneshvar; Shemirani, Farzaneh

    2014-06-01

    A simple and rapid method for the simultaneous in situ derivatizaion, preconcentration and extraction of thiamine (vitamin B1) as a model analyte was developed by a novel quantitative method, namely ultrasound-assisted dispersive magnetic solid phase extraction spectrofluorimetry (USA-DMSPE-FL) from different real samples. This method consists of sample preparation, in situ derivatization, exhaustive extraction and clean up by a single process. High extraction efficiency and in situ derivatization in a short period of time is the main advantages of this procedure. For this purpose, the reusable magnetic multi-wall carbon nanotube (MMWCNT) nanocomposite was used as an adsorbent for preconcentration and determination of thiamine. Thiamine was, simultaneously, in situ derivatized as thiochrome by potassium hexacyanoferrate (III) and adsorbed on MMWCNT in an ultrasonic water bath. The MMWCNTs were then collected using an external magnetic field. Subsequently, the extracted thiochrome was washed from the surface of the adsorbent and determined by spectrofluorimetry. The developed method, which has been analytically characterized under its optimal operating conditions, allows the detection of the analyte in the samples with method detection limits of 0.37 µg L(-1). The repeatability of the method, expressed as the relative standard deviation (RSD, n=6), varies between 2.0% and 4.8% in different real samples, while the enhancement factor is 197. The proposed procedure has been applied for the determination of thiamine in biological (serum and urine), pharmaceutical (multivitamin tablet and B complex syrup) and foodstuff samples (cereal, wheat flour, banana and honey) with the good recoveries in the range from 90% to 105%. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Determination of hydroxyurea in human plasma by HPLC-UV using derivatization with xanthydrol.

    Science.gov (United States)

    Legrand, Tiphaine; Rakotoson, Marie-Georgine; Galactéros, Frédéric; Bartolucci, Pablo; Hulin, Anne

    2017-10-01

    A simple and rapid high performance liquid chromatography (HPLC) method using ultraviolet (UV) detection was developed to determine hydroxyurea (HU) concentration in plasma sample after derivatization with xanthydrol. Two hundred microliters samples were spiked with methylurea (MeU) as internal standard and proteins were precipitated by adding methanol. Derivatization of HU and MeU was immediately performed by adding 0.02M xanthydrol and 1.5M HCl in order to obtain xanthyl-derivatives of HU and MeU that can be further separated using HPLC and quantified using UV detection at 240nm. Separation was achieved using a C18 column with a mobile phase composed of 20mM ammonium acetate and acetonitrile in gradient elution mode at a flow rate of 1mL/min. The total analysis time did not exceed 18min. The method was found linear from 5 to 400μM and all validation parameters fulfilled the international requirements. Between- and within-run accuracy error ranged from -4.7% to 3.2% and precision was lower than 12.8%. This simple method requires small volume samples and can be easily implemented in most clinical laboratories to develop pharmacokinetics studies of HU and to promote its therapeutic monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Quantification of monosialogangliosides in human plasma through chemical derivatization for signal enhancement in LC–ESI-MS

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Qianyang; Liu, Danting [Clinical Chemistry Program, Department of Chemistry, Cleveland State University, 2121 Euclid Avenue, Cleveland, OH 44115 (United States); Xin, Baozhong; Cechner, Karen [DDC Clinic, Center for Special Needs Children, 14567 Madison Road, Middlefield, OH 44062 (United States); Zhou, Xiang [Clinical Chemistry Program, Department of Chemistry, Cleveland State University, 2121 Euclid Avenue, Cleveland, OH 44115 (United States); Wang, Heng, E-mail: Wang@ddcclinic.org [DDC Clinic, Center for Special Needs Children, 14567 Madison Road, Middlefield, OH 44062 (United States); Zhou, Aimin, E-mail: a.zhou@csuohio.edu [Clinical Chemistry Program, Department of Chemistry, Cleveland State University, 2121 Euclid Avenue, Cleveland, OH 44115 (United States); Center for Gene Regulation in Health and Diseases, Cleveland State University, 2121 Euclid Avenue, Cleveland, OH 44115 (United States)

    2016-07-27

    Gangliosides are found in abundance in the central nervous system of vertebrates. Their metabolic disruption and dysfunction are associated with various neurodegenerative disorders such as Alzheimer's disease and Parkinson's disease. In order to improve our understanding of the etiology of these diseases, analytical ganglioside assays with sufficient specificity and sensitivity in relevant biological matrices are required. In the present work we have developed and validated a reverse-phase ultra-performance liquid chromatography (UPLC)/tandem mass spectrometry (MS) method for determining monosialogangliosides GM1, GM2, and GM3 present in human plasma. Compared with our previous method, this method enhanced, by 15 fold, MS responses of the analytes by employing 2-(2-Pyridilamino)-ethylamine (PAEA) & 4-(4, 6-Dimethoxy-1, 3, 5-triazin-2-yl)-4-methylmorpholinium chloride (DMTMM)-based derivatization. The analytes and internal standards were derivatized with PAEA&DMTMM after extraction from plasma using a protein precipitation procedure. They were then purified using liquid–liquid partitioning. When the samples were then analyzed by UPLC-MS/MS with a multiple reaction monitoring (MRM) mode, we achieved superior sensitivity and specificity. This method was evaluated for extraction recovery, calibration linearity, precision, accuracy, and lower limit of quantification (LLOQ). The validated method was successfully applied to monitor monosialoganglioside levels in the plasma from patients with GM3 synthase deficiency. With significantly increased sensitivity, we have, for the first time, detected a significant amount of GM3 in the affected patients. - Highlights: • A UPLC/MS/MS method for analyzing monosialogangliosides GM1, GM2, and GM3 in human plasma was developed and validated. • PAEA&DMTMM-based derivatization greatly improved the sensitivity. • The method was applied to measure GM1, GM2, and GM3 in the plasma from the patients with GM3 synthase

  14. Determination of oxidation products of 5-methylcytosine in plants by chemical derivatization coupled with liquid chromatography/tandem mass spectrometry analysis.

    Science.gov (United States)

    Tang, Yang; Xiong, Jun; Jiang, Han-Peng; Zheng, Shu-Jian; Feng, Yu-Qi; Yuan, Bi-Feng

    2014-08-05

    Cytosine methylation (5-methylcytosine, 5-mC) in DNA is an important epigenetic mark that has regulatory roles in various biological processes. In plants, active DNA demethylation can be achieved through direct cleavage by DNA glycosylases, followed by replacement of 5-mC with cytosine by base excision repair (BER) machinery. Recent studies in mammals have demonstrated 5-mC can be sequentially oxidized to 5-hydroxymethylcytosine (5-hmC), 5-formylcytosine (5-foC), and 5-carboxylcytosine (5-caC) by Ten-eleven translocation (TET) proteins. The consecutive oxidations of 5-mC constitute the active DNA demethylation pathway in mammals, which raised the possible presence of oxidation products of 5-mC (5-hmC, 5-foC, and 5-caC) in plant genomes. However, there is no definitive evidence supporting the presence of these modified bases in plant genomic DNA, especially for 5-foC and 5-caC. Here we developed a chemical derivatization strategy combined with liquid chromatography-electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method to determine 5-formyl-2'-deoxycytidine (5-fodC) and 5-carboxyl-2'-deoxycytidine (5-cadC). Derivatization of 5-fodC and 5-cadC by Girard's reagents (GirD, GirT, and GirP) significantly increased the detection sensitivities of 5-fodC and 5-cadC by 52-260-fold. Using this method, we demonstrated the widespread existence of 5-fodC and 5-cadC in genomic DNA of various plant tissues, indicating that active DNA demethylation in plants may go through an alternative pathway similar to mammals besides the pathway of direct DNA glycosylases cleavage combined with BER. Moreover, we found that environmental stresses of drought and salinity can change the contents of 5-fodC and 5-cadC in plant genomes, suggesting the functional roles of 5-fodC and 5-cadC in response to environmental stresses.

  15. A new polyethyleneglycol-derivatized hemoglobin derivative with decreased oxygen affinity and limited toxicity.

    Science.gov (United States)

    Zolog, Oana; Mot, Augustin; Deac, Florina; Roman, Alina; Fischer-Fodor, Eva; Silaghi-Dumitrescu, Radu

    2011-01-01

    A new protocol is described for derivatization of hemoglobin with polyethyleneglycol (PEG) via reaction of the unmodified native hemoglobin with an activated amine-reacting polyethylene glycol derivative which, unlike protocols previously described, leads to formation of a peptide bond between hemoglobin and PEG. Dioxygen binding and peroxide reactivities of the derivatized hemoglobin are examined, and found to be within reasonable limits, with the particular observation that, unlike with a few other derivatization protocols, the dioxygen affinity is slightly lower than that of native Hb. In cell culture tests (human umbilical vein epithelial cells, HUVEC), the derivatization protocol induces no toxic effect. These results show promise towards applicability for production of hemoglobin-based blood substitutes.

  16. Rapid Determination of the Monosaccharide Composition and Contents in Tea Polysaccharides from Yingshuang Green Tea by Pre-Column Derivatization HPLC

    OpenAIRE

    Ai, Yujie; Yu, Zhi; Chen, Yuqiong; Zhu, Xiaojing; Ai, Zeyi; Liu, Shuyuan; Ni, Dejiang

    2016-01-01

    A pre-column derivatization high-performance liquid chromatography (HPLC) method was developed and optimized to characterize and quantify the monosaccharides present in tea polysaccharides (TPS) isolated from Yingshuang green tea. TPS sample was hydrolyzed with trifluoroacetic acid, subjected to pre-column derivatization using 1-phenyl-3-methyl-5-pyrazolone (PMP), and separated on an Agilent TC-C18 column (4.6 mm × 250 mm, 5 μm) with UV detection at 250 nm. A mixture of ten PMP derivatives of...

  17. Speciation of mercury compounds by gas chromatography with atomic emission detection. Simultaneous optimization of a headspace solid-phase microextraction and derivatization procedure by use of chemometric techniques

    Energy Technology Data Exchange (ETDEWEB)

    Carro, A.M.; Neira, I.; Rodil, R.; Lorenzo, R. A. [Univ. Santiago de Compostela (Spain). Dpto. Quimica Analitica, Nutricion y Bromatologia

    2003-06-01

    A method is proposed for the extraction and determination of organomercury compounds and Hg(II) in seawater samples by headspace solid-phase microextraction (HS-SPME) combined with capillary gas chromatography-microwave-induced plasma atomic emission spectrometry. The mercury species were derivatized with sodium tetraphenylborate, sorbed on a polydimethylsiloxane-coated fused-silica fibre, and desorbed in the injection port of the GC, in splitless mode. Experimental design methodology was used to evaluate the effect of six HS-SPME-derivatization variables: sample volume, NaBPh{sub 4} volume, pH, sorption time, extraction-derivatization temperature, and rate of stirring. Use of a multicriterion decision-making approach, with the desirability function, enabled determination of the optimum working conditions of the procedure for simultaneous analysis of three mercury species. (orig.)

  18. [Analysis of thickening polysaccharides by the improved diethyldithioacetal derivatization method].

    Science.gov (United States)

    Akiyama, Takumi; Yamazaki, Takeshi; Tanamoto, Kenichi

    2011-01-01

    The identification test for thickening polysaccharides containing neutral saccharides and uronic acids was investigated by GC analysis of constituent monosaccharides. The reported method, in which monosaccharides were converted to diethyldithioacetal derivatives with ethanethiol followed by trimethylsilylation, was improved in terms of operability and reproducibility of GC/MS analysis. The suitability of the improved diethyldithioacetal derivatization method was determined for seven thickening polysaccharides, i.e., carob bean gum, guar gum, karaya gum, gum arabic, gum ghatti, tragacanth gum and peach gum. The samples were acid-hydrolyzed to form monosaccharides. The hydrolysates were derivatized and analyzed with GC/FID. Each sugar derivative was detected as a single peak and was well separated from others on the chromatograms. The amounts of constituent monosaccharides in thickening polysaccharides were successfully estimated. Seven polysaccharides were distinguished from each other on the basis of constituent monosaccharides. Further examination of the time period of hydrolysis of polysaccharides using peach gum showed that the optimal times were not the same for all monosaccharides. A longer time was needed to hydrolyze glucuronic acid than neutral saccharides. The findings suggest that hydrolysis time may sometimes affect the analytical results on composition of constituent monosaccharides in polysaccharides.

  19. Combined solid-phase extraction and gas chromatography-mass spectrometry used for determination of chloropropanols in water.

    Science.gov (United States)

    González, Paula; Racamonde, Inés; Carro, Antonia M; Lorenzo, Rosa A

    2011-10-01

    A sensitive and rapid derivatization method for the simultaneous determination of 1,3-dichloro-2-propanol (1,3-DCP) and 3-chloropropane-1,2-diol (3-MCPD) in water samples has been developed. The aim was to research the optimal conditions of the derivatization process for two selected reagents. A central composite design was used to determine the influence of derivatization time, derivatization temperature and reagent volume. A global desirability function was applied for multi-response optimization. The analysis was performed by gas chromatography-mass spectrometry. During the optimization of the extraction procedure, four different types of solid-phase extraction (SPE) columns were tested. It was demonstrated that the Oasis HLB cartridge produced the best recoveries of the target analytes. The pH value and the salinity were investigated using a Doehlert design. The best results for the SPE of both analytes were obtained with 1.5 g of NaCl and pH 6. The proposed method provides high sensitivity, good linearity (R(2)≥0.999) and repeatability (relative standard deviations % between 2.9 and 3.4%). Limits of detection and quantification were in the range of 1.4-11.2 ng/mL and 4.8-34.5 ng/mL, respectively. Recoveries obtained for water samples were ca. 100% for 1,3-DCP and 3-MCPD. The method has been successfully applied to the analysis of different samples including commercially bottled water, an influent and effluent sewage. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Simultaneous determination of amino acid and monoamine neurotransmitters in PC12 cells and rats models of Parkinson's disease using a sensitizing derivatization reagent by UHPLC-MS/MS.

    Science.gov (United States)

    Zhao, Xian-En; Zhu, Shuyun; Yang, Hongmei; You, Jinmao; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying

    2015-07-15

    Multi-analytes simultaneous monitoring of amino acid and monoamine neurotransmitters (NTs) has important scientific significance for their related pathology, physiology and drug screening. In this work, in virtue of a mass spectrometry sensitizing reagent 10-ethyl-acridone-3-sulfonyl chloride (EASC) as derivatization reagent, an Ultra High Performance Liquid Chromatography-Tandem Mass Spectrometry (UHPLC-MS/MS) method was developed and validated for simultaneous determination of six amino acid NTs, two monoamine ones and its one metabolite. The simple and rapid derivatization reaction was innovatively combined with plasma preparation by using EASC acetonitrile solution as protein precipitant. This interesting combination brought the advantages of speediness, simpleness and high-throughput in a cost-effective way. Under the optimized conditions, LODs (0.004-3.80nM) and LOQs (0.014-13.3nM) of EASC derivatized-NTs were calculated and found to be significantly lower than those of direct UHPLC-MS/MS detection about 11.5-275.0 and 14.4-371.4 times, respectively. Moreover, EASC derivatization significantly improved chromatographic resolution and matrix effect when compared with direct UPLC-MS/MS detection method without derivatization. Meanwhile, it also brought acceptable precision (3.0-13.0%, peak area CVs%), accuracy (86.4-112.9%), recovery (88.3-107.8%) and stability (3.8-8.5%, peak area CVs%) results. This method was successfully applied for the antiparkinsonian effect evaluation of levodopa and Ginsenoside Rg1 using PC12 cells and rats models by measuring multiple NTs. This provided a new method for the NTs related studies in the future. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Capillary electrophoresis fingerprinting, quantification and mass-identification of various 9-aminopyrene-1,4,6-trisulfonate-derivatized oligomers derived from plant polysaccharides

    NARCIS (Netherlands)

    Kabel, M.A.; Heijnis, W.H.; Bakx, E.J.; Kuijpers, I.J.; Voragen, A.G.J.; Schols, H.A.

    2006-01-01

    Various plant polysaccharide derived mono- and oligosaccharides were derivatized with the fluorescent 9-aminopyrene-1,4,6-trisulfonate (APTS) and subjected to capillary electrophoresis (CE) in combination with laser induced fluorescence (LIF) detection. CE-LIF was suitable for mol-based

  2. Atmospheric pressure chemical ionization Fourier transform ion cyclotron resonance mass spectrometry for complex thiophenic mixture analysis

    KAUST Repository

    Hourani, Nadim

    2013-10-01

    Rationale Polycyclic aromatic sulfur heterocycles (PASHs) are detrimental species for refining processes in petroleum industry. Current mass spectrometric Methods that determine their composition are often preceded by derivatization and dopant addition approaches. Different ionization Methods have different impact on the molecular assignment of complex PASHs. The analysis of such species under atmospheric pressure chemical ionization (APCI) is still considered limited due to uncontrolled ion generation with low- and high-mass PASHs. Methods The ionization behavior of a model mixture of five selected PASH standards was investigated using an APCI source with nitrogen as the reagent gas. A complex thiophenic fraction was separated from a vacuum gas oil (VGO) and injected using the same method. The samples were analyzed using Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS). RESULTS PASH model analytes were successfully ionized and mainly [M + H]+ ions were produced. The same ionization pattern was observed for the real thiophenic sample. It was found that S1 class species were the major sulfur-containing species found in the VGO sample. These species indicated the presence of alkylated benzothiophenic (BT), dibenzothiophenic (DBT) and benzonaphthothiophenic (BNT) series that were detected by APCI-FTICR MS. CONCLUSIONS This study provides an established APCI-FTICR MS method for the analysis of complex PASHs. PASHs were detected without using any derivatization and without fragmentation. The method can be used for the analysis of S-containing crude oil samples. © 2013 John Wiley & Sons, Ltd.

  3. The big six, regnskabsbrugerne og FASBs nye regler om derivater

    DEFF Research Database (Denmark)

    Thinggaard, Frank

    1997-01-01

    Artiklen har flere formål. Dels at præsentere FASBs første forslag til den regnskabsmæssige behandling af samtlige derivater. Dels at analysere og sammenligne de enkelte big six revisions-firmaers holdning til forslagets vigtigste emner samt at sammenligne dette med kommentarerne fra en repræsent......Artiklen har flere formål. Dels at præsentere FASBs første forslag til den regnskabsmæssige behandling af samtlige derivater. Dels at analysere og sammenligne de enkelte big six revisions-firmaers holdning til forslagets vigtigste emner samt at sammenligne dette med kommentarerne fra en...... repræsentant for brugerne. Artiklen viser, at revisionsfirmaerne generelt er meget enige i deres bedømmelse af reglerne. De fleste er ikke modstandere af at værdiansætte derivater til fair value. Kritikken går på behandlingen af gevinsterne og tabene, hvor de er bange for den volatilitet, der kan komme i...... virksomhedernes resultater. Især for gevinster og tab på derivater, der sikrer fremtidige cash-flows. Artiklen forklarer nærmere, hvad modstanden består i, hvilket giver en dybere forståelse for, hvordan reglerne virker. Artiklen viser, at brugerne ikke er nær så kritiske som the big six....

  4. Representative mass reduction in sampling

    DEFF Research Database (Denmark)

    Petersen, Lars; Esbensen, Harry Kim; Dahl, Casper Kierulf

    2004-01-01

    We here present a comprehensive survey of current mass reduction principles and hardware available in the current market. We conduct a rigorous comparison study of the performance of 17 field and/or laboratory instruments or methods which are quantitatively characterized (and ranked) for accuracy...... dividers, the Boerner Divider, the ??spoon method??, alternate/fractional shoveling and grab sampling. Only devices based on riffle splitting principles (static or rotational) passes the ultimate representativity test (with minor, but significant relative differences). Grab sampling, the overwhelmingly...... most often used mass reduction method, performs appallingly?its use must be discontinued (with the singular exception for completely homogenized fine powders). Only proper mass reduction (i.e. carried out in complete compliance with all appropriate design principles, maintenance and cleaning rules) can...

  5. Measurement of respirable superabsorbent polyacrylate (SAP) dust by ethanol derivatization using gas chromatography-mass spectrometry (GC-MS) detection.

    Science.gov (United States)

    McCormack, Paul; Lemmo, John S; Macomber, Margaret; Holcomb, Mark L; Lieckfield, Robert

    2011-04-01

    Superabsorbent polyacrylate (SAP) is an important industrial chemical manufactured primarily as sodium polyacrylate but occasionally as potassium salt. It has many applications owing to its intrinsic physical property of very high water absorption, which can be more than 100 times it own weight. SAP is commonly used in disposable diapers and feminine hygiene products and is known by a number of synonyms-sodium polyacrylate, superabsorbent polyacrylate (SAP), polyacrylate absorbent (PA), and superabsorbent material (SAM). Germany and The Netherlands have adopted a nonbinding scientific guideline value 0.05 mg/m³ (8-hr time-weighted average, TWA) as the maximum allowable workplace concentration for the respirable dust of SAP (acrylate was developed and validated for the analysis of respirable superabsorbent polyacrylate dust collected on filter cassettes in the workplace environment. This method is an alternative to the commonly used sodium-based method, which is limited owing to potential interference by other sources of sodium from the workplace and laboratory environments. The alcohol derivatization method effectively eliminates sodium interference from several classes of sodium compounds, as shown by their purposeful introduction at two and six times the equivalent amount of SAP present in reference samples. The accuracy of the method, as determined by comparison with sodium analysis of known reference samples, was greater than 80% over the study range of 5-50 μg of SAP dust. The lower reporting limit of the method is 3.0 μg of SAP per sample, which is equivalent to 3 (μg/m³) for an 8-hr sampling period at the recommended flow rate of 2.2 L/min.

  6. HPLC Separation of Sulforaphane Enantiomers in Broccoli and Its Sprouts by Transformation into Diastereoisomers Using Derivatization with (S)-Leucine.

    Science.gov (United States)

    Okada, Makiko; Yamamoto, Atsushi; Aizawa, Sen-Ichi; Taga, Atsushi; Terashima, Hiroyuki; Kodama, Shuji

    2017-01-11

    Racemic sulforaphane, which was derivatized with (S)-leucine (l-leucine), was resolved by reversed phase HPLC with UV detection. The optimum mobile phase conditions were found to be 10 mM citric acid (pH 2.8) containing 22% methanol at 35 °C using detection at 254 nm. Sulforaphane enantiomers in florets and stems of five brands of broccoli and leaves and stems of three brands of broccoli sprouts were analyzed by the proposed HPLC method. Both sulforaphane enantiomers were detected in all of the samples. The S/R ratios of sulforaphane in broccoli samples were 1.5-2.6/97.4-98.5% for florets and 5.0-12.1/87.9-95.0% for stems. The S/R ratios in broccoli sprout samples were higher than those in broccoli samples and were found to be 8.3-19.7/80.3-91.7% for leaves and 37.0-41.8/58.2-63.0% for stems. (S)-Sulforaphane detected in the broccoli and its sprout samples was positively identified by separately using an HPLC with a chiral column (Chiralpak AD-RH) and mass spectrometry.

  7. A novel methylation derivatization method for δ(18)O analysis of individual carbohydrates by gas chromatography/pyrolysis-isotope ratio mass spectrometry.

    Science.gov (United States)

    Lehmann, Marco M; Fischer, Maria; Blees, Jan; Zech, Michael; Siegwolf, Rolf T W; Saurer, Matthias

    2016-01-15

    The oxygen isotope ratio (δ(18)O) of carbohydrates derived from animals, plants, sediments, and soils provides important information about biochemical and physiological processes, past environmental conditions, and geographical origins, which are otherwise not available. Nowadays, δ(18)O analyses are often performed on carbohydrate bulk material, while compound-specific δ(18)O analyses remain challenging and methods for a wide range of individual carbohydrates are rare. To improve the δ(18)O analysis of individual carbohydrates by gas chromatography/pyrolysis-isotope ratio mass spectrometry (GC/Pyr-IRMS) we developed a new methylation derivatization method. Carbohydrates were fully methylated within 24 h in an easy-to-handle one-pot reaction in acetonitrile, using silver oxide as proton acceptor, methyl iodide as methyl group carrier, and dimethyl sulfide as catalyst. The precision of the method ranged between 0.12 and 1.09‰ for the δ(18)O values of various individual carbohydrates of different classes (mono-, di-, and trisaccharides, alditols), with an accuracy of a similar order of magnitude, despite high variation in peak areas. Based on the δ(18)O values of the main isomers, important monosaccharides such as glucose and fructose could also be precisely analyzed for the first time. We tested the method on standard mixtures, honey samples, and leaf carbohydrates extracted from Pinus sylvestris, showing that the method is also applicable to different carbohydrate mixtures. The new methylation method shows unrivalled accuracy and precision for δ(18)O analysis of various individual carbohydrates; it is fast and easy-to-handle, and may therefore find wide-spread application. Copyright © 2015 John Wiley & Sons, Ltd.

  8. Derivatization reactions in the gas—liquid chromatographic analysis of drugs in biological fluids

    NARCIS (Netherlands)

    Hulshoff, A.; Lingeman, H.

    1984-01-01

    Alkylation, acylation, silylation and other derivatization reactions applied to the gas chromatographic analysis of drugs in biological matrices are reviewed. Reaction conditions are discussed in relation to reaction mechanisms. Detector-oriented labelling of drugs, and derivatization with chiral

  9. Glucose and glycerol concentrations and their tracer enrichment measurements using liquid chromatography tandem mass spectrometry

    DEFF Research Database (Denmark)

    Bornø, Andreas; Foged, Lene; van Hall, Gerrit

    2014-01-01

    The present study describes a new liquid chromatography tandem mass spectrometry method for high-throughput quantification of glucose and glycerol in human plasma using stable isotopically labeled internal standards and is suitable for simultaneous measurements of glucose and glycerol enrichments...... of variation were 2.0% and 9.7%, respectively. After derivatization, plasma samples were stable for at least 14 days. In conclusion, we have developed and validated a novel, accurate, and sensitive high-throughput liquid chromatography tandem mass spectrometry method for simultaneous determination of glucose...

  10. Rapid and sensitive determination of phytosterols in functional foods and medicinal herbs by using UHPLC-MS/MS with microwave-assisted derivatization combined with dual ultrasound-assisted dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Sun, Jing; Zhao, Xian-En; Dang, Jun; Sun, Xiaoyan; Zheng, Longfang; You, Jinmao; Wang, Xiao

    2017-02-01

    In this work, a hyphenated technique of dual ultrasound-assisted dispersive liquid-liquid microextraction combined with microwave-assisted derivatization followed by ultra high performance liquid chromatography tandem mass spectrometry has been developed for the determination of phytosterols in functional foods and medicinal herbs. Multiple reaction monitoring mode was used for the tandem mass spectrometry detection. A mass spectrometry sensitive reagent, 4'-carboxy-substituted rosamine, has been used as the derivatization reagent for five phytosterols, and internal standard diosgenin was used for the first time. Parameters for the dual microextraction, microwave-assisted derivatization, and ultra high performance liquid chromatography tandem mass spectrometry were all optimized in detail. Satisfactory linearity, recovery, repeatability, accuracy and precision, absence of matrix effect, extremely low limits of detection (0.005-0.015 ng/mL) and limits of quantification (0.030-0.10 ng/mL) were achieved. The proposed method was compared with previously reported methods. It showed better sensitivity, selectivity, and accuracy. The matrix effect was also significantly reduced. The proposed method was successfully applied to the determination of five phytosterols in vegetable oil (sunflower oil, olive oil, corn oil, peanut oil), milk and orange juice (soymilk, peanut milk, orange juice), and medicinal herbs (Ginseng, Ganoderma lucidum, Cordyceps, Polygonum multiflorum) for the quality control of functional foods and medicinal herbs. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. [Determination of fatty acid esters of chloropropanediols in diet samples by gas chromatography-mass spectrometry coupled with solid-supported liquid-liquid extraction].

    Science.gov (United States)

    Gao, Jie; Liu, Qing; Han, Feng; Miao, Hong; Zhao, Yunfeng; Wu, Yongning

    2014-05-01

    To establish a method for the determination of fatty acid esters of 3-monochloropropane-1, 2-diol (3-MCPD) and 2-monochloropropane-1, 3-diol (2-MCPD) in diet samples by gas chromatography-mass spectrometry (GC-MS) with solid-supported liquid-liquid extraction (SLE). Diet samples were ultrasonically extracted by hexane, followed by ester cleavage reaction with sodium methylate in methanol, and then purified by solid-supported liquid-liquid extraction. (SLE) using diatomaceous earth as the sorbent. After derivatization with heptafluorobutyrylimidazole, the analytes were detected by GC-MS and quantified by the deuterated internal standards. The limits of detection (LODs) of 3-MCPD esters and 2-MCPD esters in different diet samples were 0.002 - 0.005 mg/kg and 0.002 - 0.006 mg/kg. The average recoveries of 3-MCPD esters and 2-MCPD esters at the spiking levels of 0.05 and 0.1 mg/kg in the diet samples were in the range of 65.9% - 104.2% and 75.4% - 118.0%, respectively, with the relative standard deviations in the range of 2.2% - 14.2% and 0.8% - .13.9%. The method is simple, accurate and rugged for the determination of fatty acid esters of 3-MCPD and 2-MCPD in diet samples.

  12. Determination of captopril in biological samples by high-performance liquid chromatography with ThioGlo 3 derivatization.

    Science.gov (United States)

    Aykin, N; Neal, R; Yusof, M; Ercal, N

    2001-11-01

    Captopril, a well-known angiotensin converting enzyme (ACE) inhibitor, is widely used for treatment of arterial hypertension. Recent studies suggest that it may also act as a scavenger of free radicals because of its thiol group. Therefore, the present study describes a rapid, sensitive and relatively simple method for the detection of captopril in biological tissues with reverse-phase HPLC. Captopril was first derivatized with ThioGlo 3 [3H-Naphto[2,1-b]pyran,9-acetoxy-2-(4-(2,5-dihydro-2,5-dioxo-1H-pyrrol-1-yl)phenyl-3-oxo-)]. It was then detected by fluorescence-HPLC using an Astec C(18) column as the stationary phase and a water:acetonitrile:acetic acid:phosphoric acid mixture (50:50; 1 mL/L acids) as the mobile phase (excitation wavelength, 365 nm; emission wavelength, 445 nm). The calibration curve for captopril was linear over a range of 10-2500 nM and the coefficient of variation acquired for the within- and between-run precision for captopril was 0.5 and 3.8%, respectively. The detection limit of captopril with this method was found to be 200 fmol/20 microL injection volume. Its relative recovery from biological samples was determined to the range from 93.3 to 105.3%. Based on these results, we believe that our method is advantageous for captopril determination. Copyright 2001 John Wiley & Sons, Ltd.

  13. Microanalysis of oligosaccharide HS203 in beagle dog plasma by postcolumn fluorescence derivatization method.

    Science.gov (United States)

    Sun, Shumeng; Zhao, Xia; Li, Guangsheng; Yu, Guangli; Xing, Xiaoxu; Zeng, Yangyang; Wu, Jian; Wang, Jianing

    2012-06-20

    A rapid and sensitive postcolumn fluorescence derivatization method was developed for microanalysis of antidiabetic oligosaccharide HS203 in beagle dog plasma. After plasma protein was removed by a simple and fast ultrafiltration method, chromatographic separation was performed on an Asahipak GS-320 HQ column with a mobile phase of 50 mmol/L phosphate buffer (pH 6.7) and acetonitrile (83/17, v/v). The column effluent was monitored by fluorescence detection at 249 nm (excitation) and 435 nm (emission) using guanidine hydrochloride as a postcolumn derivatizing reagent. A satisfactory resolution of the analyte was achieved and the limit of detection was found to be 4 ng (more sensitive than silver staining of HS203 in polyacrylamide gel electrophoresis). The method described above was successfully applied to a pharmacokinetic study of HS203 and to monitor blood glucose level simultaneously in beagle dog. It is also possible to be applied for microanalysis of other oligosaccharides in biological samples. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Molecular Characterization of Thiols in Fossil Fuels by Michael Addition Reaction Derivatization and Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry.

    Science.gov (United States)

    Wang, Meng; Zhao, Suoqi; Liu, Xuxia; Shi, Quan

    2016-10-04

    Thiols widely occur in sediments and fossil fuels. However, the molecular composition of these compounds is unclear due to the lack of appropriate analytical methods. In this work, a characterization method for thiols in fossil fuels was developed on the basis of Michael addition reaction derivatization followed by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI FT-ICR MS). Model thiol compound studies showed that thiols were selectively reacted with phenylvinylsulfone and transformed to sulfones with greater than 98% conversions. This method was applied to a coker naphtha, light and heavy gas oils, and crude oils from various geological sources. The results showed that long alkyl chain thiols are readily present in petroleum, which have up to 30 carbon atoms. Large DBE dispersity of thiols indicates that naphthenic and aromatic thiols are also present in the petroleum. This method is capable of detecting thiol compounds in the part per million range by weight. This method allows characterization of thiols in a complex hydrocarbon matrix, which is complementary to the comprehensive analysis of sulfur compounds in fossil fuels.

  15. Development of a rapid and sensitive LC-ESI/MS/MS assay for the quantification of propofol using a simple off-line dansyl chloride derivatization reaction to enhance signal intensity.

    Science.gov (United States)

    Beaudry, Francis; Guénette, Sarah Annie; Winterborn, Andrew; Marier, Jean-Francois; Vachon, Pascal

    2005-09-15

    A rapid, selective and sensitive method was developed for the determination of propofol concentration using an off-line dansyl chloride derivatization step to enhance signal intensity. The method consisted of a protein precipitation extraction followed by derivatization with dansyl chloride and analysis by liquid chromatography ionspray tandem mass spectrometry (LC-ESI/MS/MS). The separation was achieved using a 100 mm x 2 mm C8 analytical column combined with an isocratic mobile phase composed of 80:20 acetonitrile: 0.5% formic acid in water. Signal intensity of the propofol-dansyl chloride derivative was increased up to 200-fold as compared to the underivatized propofol in positive electrospray mode. An analytical range of 20-20,000 ng/mL was used in the calibration curve of plasma and blood samples. The novel method met all requirements of specificity, sensitivity, linearity, precision, accuracy and stability. A pharmacokinetic study was performed in rats and the novel analytical method was used as a routine analysis to provide enhanced measurements of plasma and blood concentrations of propofol. Blood and plasma pharmacokinetic results show that a very important fraction of propofol distributes into red blood cells. In conclusion, a rapid and sensitive LC-ESI/MS/MS method using a derivatization agent was developed to enhance signal intensity of propofol. Routine analysis with the novel method provided accurate results and enhanced the detection levels of plasma and blood concentrations of propofol to better characterize the in vivo biodisposition of propofol.

  16. Fast and accurate preparation fatty acid methyl esters by microwave-assisted derivatization in the yeast Saccharomyces cerevisiae.

    Science.gov (United States)

    Khoomrung, Sakda; Chumnanpuen, Pramote; Jansa-ard, Suwanee; Nookaew, Intawat; Nielsen, Jens

    2012-06-01

    We present a fast and accurate method for preparation of fatty acid methyl esters (FAMEs) using microwave-assisted derivatization of fatty acids present in yeast samples. The esterification of free/bound fatty acids to FAMEs was completed within 5 min, which is 24 times faster than with conventional heating methods. The developed method was validated in two ways: (1) through comparison with a conventional method (hot plate) and (2) through validation with the standard reference material (SRM) 3275-2 omega-3 and omega-6 fatty acids in fish oil (from the Nation Institute of Standards and Technology, USA). There were no significant differences (P>0.05) in yields of FAMEs with both validations. By performing a simple modification of closed-vessel microwave heating, it was possible to carry out the esterification in Pyrex glass tubes kept inside the closed vessel. Hereby, we are able to increase the number of sample preparations to several hundred samples per day as the time for preparation of reused vessels was eliminated. Pretreated cell disruption steps are not required, since the direct FAME preparation provides equally quantitative results. The new microwave-assisted derivatization method facilitates the preparation of FAMEs directly from yeast cells, but the method is likely to also be applicable for other biological samples.

  17. Immobilisation of ligands by radio-derivatized polymers; Immobilisering av ligander med radioderiverte polymerer

    Energy Technology Data Exchange (ETDEWEB)

    Varga, J.M.; Fritsch, P.

    1995-01-30

    The invention relates to radio-derivatized polymers and a method of producing them by contacting non-polymerizable conjugands with radiolysable polymers in the presence of irradiation. The resulting radio-derivatized polymers can be further linked with ligand of organic or inorganic nature to immobilize such ligands. 2 figs., 5 tabs.

  18. Effects of extraction and derivatization techniques on recovery of organotin species in environmental matrices (W3)

    International Nuclear Information System (INIS)

    Wahlen, R.; Catterick, T.

    2002-01-01

    Full text: Organotin (OT) contamination is still persistent in most coastal environments and estuaries and can be monitored accurately by analysis of sediments and sedentary aquatic animal populations. In addition to human exposure via contaminated seafood, there is increasing concern about OT compounds in man-made consumer products. Organotin analysis involves the extraction from the matrix, derivatization (for GC analysis), separation of the different species and detection. Commonly used extraction techniques are mechanical shaking, ultrasonic agitation and microwave leaching (open or closed vessel). Accelerated solvent extraction (ASE) has also been reported. In this study, closed-vessel microwave extraction and ASE methods are compared for OT analysis in environmental tissues using separation by gas chromatography (GC) and detection by inductively coupled plasma mass-spectrometry (ICP-MS). The efficiency of an ethylation procedure with sodiumtetraethylborate (NABEt 4 ) using different matrices and derivatization durations is monitored by comparing data obtained by external calibration with results by species-specific isotope dilution analysis (SS-IDMS) of dibutyltin (TBT) and dibutyltin (DBT) enriched with 117 Sn. Uncertainty estimates for both quantification techniques will be provided. (author)

  19. Process for derivatizing carbon nanotubes with diazonium species and compositions thereof

    Science.gov (United States)

    Tour, James M. (Inventor); Bahr, Jeffrey L. (Inventor); Yang, Jiping (Inventor)

    2011-01-01

    Methods for the chemical modification of carbon nanotubes involve the derivatization of multi- and single-wall carbon nanotubes, including small diameter (ca. 0.7 nm) single-wall carbon nanotubes, with diazonium species. The method allows the chemical attachment of a variety of organic compounds to the side and ends of carbon nanotubes. These chemically modified nanotubes have applications in polymer composite materials, molecular electronic applications, and sensor devices. The methods of derivatization include electrochemical induced reactions, thermally induced reactions, and photochemically induced reactions. Moreover, when modified with suitable chemical groups, the derivatized nanotubes are chemically compatible with a polymer matrix, allowing transfer of the properties of the nanotubes (such as, mechanical strength or electrical conductivity) to the properties of the composite material as a whole. Furthermore, when modified with suitable chemical groups, the groups can be polymerized to form a polymer that includes carbon nanotubes.

  20. High-precision quadruple isotope dilution method for simultaneous determination of nitrite and nitrate in seawater by GCMS after derivatization with triethyloxonium tetrafluoroborate

    Energy Technology Data Exchange (ETDEWEB)

    Pagliano, Enea, E-mail: enea.pagliano@nrc-cnrc.gc.ca; Meija, Juris; Mester, Zoltán

    2014-05-01

    Highlights: • High-precision determination of nitrite and nitrate in seawater. • Use of quadruple isotope dilution. • Aqueous Et₃O⁺BF₄]⁻ derivatization chemistry for GCMS analysis of nitrite and nitrate. Abstract: Quadruple isotope dilution mass spectrometry (ID⁴MS) has been applied for simultaneous determination of nitrite and nitrate in seawater. ID⁴MS allows high-precision measurements and entails the use of isotopic internal standards (¹⁸O-nitrite and ¹⁵N-nitrate). We include a tutorial on ID⁴MS outlining optimal experimental design which generates results with low uncertainties and obviates the need for direct (separate) evaluation of the procedural blank. Nitrite and nitrate detection was achieved using a headspace GCMS procedure based on single-step aqueous derivatization with triethyloxonium tetrafluoroborate at room temperature. In this paper the sample preparation was revised and fundamental aspects of this chemistry are presented. The proposed method has detection limits in the low parts-per-billion for both analytes, is reliable, precise, and has been validated using a seawater certified reference material (MOOS-2). Simplicity of the experimental design, low detection limits, and the use of quadruple isotope dilution makes the present method superior to the state-of-the-art for determination of nitrite and nitrate, and an ideal candidate for reference measurements of these analytes in seawater.

  1. MultiSimplex optimization of chromatographic separation and dansyl derivatization conditions in the ultra performance liquid chromatography-tandem mass spectrometry analysis of risperidone, 9-hydroxyrisperidone, monoamine and amino acid neurotransmitters in human urine.

    Science.gov (United States)

    Cai, Hua-Lin; Zhu, Rong-Hua; Li, Huan-De; Zhang, Jun; Li, Lan-Fang

    2011-07-01

    A pre-column dansylated ultra-performance liquid chromatography-electrospray ionization tandem mass spectrometry (UPLC-MS/MS) method for simultaneous determination of risperidone (RIP), 9-hydroxyrisperidone (9-OH-RIP), monoamine and amino acid neurotransmitters in human urine was developed with the aim of providing data on how neurotransmitters may influence each other or change simultaneously in response to risperidone treatment. MultiSimplex based on the simplex algorithm and the fuzzy set theory was applied to the optimization of chromatographic separation and dansyl derivatization conditions during method development. This method exhibited excellent linearity for all the analytes with regression coefficients higher than 0.997. The lower limit of quantification (LLOQ) values for 9-OH-RIP and RIP were 0.11 and 0.06 ng/ml, respectively, and for neurotrasmitters ranged from 0.31 to 12.8 nM. The mean accuracy ranged from 94.7% to 108.5%. The mean recovery varied between 81.6% and 97.5%. All the RSD of precision and stability were below 9.7%. Finally, the optimized method was applied to analyze the first morning urine samples of schizophrenic patients treated with risperidone and healthy volunteers. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Stable-isotope dilution GC-MS approach for nitrite quantification in human whole blood, erythrocytes, and plasma using pentafluorobenzyl bromide derivatization: nitrite distribution in human blood.

    Science.gov (United States)

    Schwarz, Alexandra; Modun, Darko; Heusser, Karsten; Tank, Jens; Gutzki, Frank-Mathias; Mitschke, Anja; Jordan, Jens; Tsikas, Dimitrios

    2011-05-15

    Previously, we reported on the usefulness of pentafluorobenzyl bromide (PFB-Br) for the simultaneous derivatization and quantitative determination of nitrite and nitrate in various biological fluids by GC-MS using their (15)N-labelled analogues as internal standards. As nitrite may be distributed unevenly in plasma and blood cells, its quantification in whole blood rather than in plasma or serum may be the most appropriate approach to determine nitrite concentration in the circulation. So far, GC-MS methods based on PFB-Br derivatization failed to measure nitrite in whole blood and erythrocytes because of rapid nitrite loss by oxidation and other unknown reactions during derivatization. The present article reports optimized and validated procedures for sample preparation and nitrite derivatization which allow for reliable quantification of nitrite in human whole blood and erythrocytes. Essential measures for stabilizing nitrite in these samples include sample cooling (0-4°C), hemoglobin (Hb) removal by precipitation with acetone and short derivatization of the Hb-free supernatant (5 min, 50°C). Potassium ferricyanide (K(3)Fe(CN)(6)) is useful in preventing Hb-caused nitrite loss, however, this chemical is not absolutely required in the present method. Our results show that accurate GC-MS quantification of nitrite as PFB derivative is feasible virtually in every biological matrix with similar accuracy and precision. In EDTA-anticoagulated venous blood of 10 healthy young volunteers, endogenous nitrite concentration was measured to be 486±280 nM in whole blood, 672±496 nM in plasma (C(P)), and 620±350 nM in erythrocytes (C(E)). The C(E)-to-C(P) ratio was 0.993±0.188 indicating almost even distribution of endogenous nitrite between plasma and erythrocytes. By contrast, the major fraction of nitrite added to whole blood remained in plasma. The present GC-MS method is useful to investigate distribution and metabolism of endogenous and exogenous nitrite in blood

  3. High-sensitivity simultaneous liquid chromatography–tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma

    Directory of Open Access Journals (Sweden)

    Abhishek Gandhi

    2015-10-01

    Full Text Available A sensitive and simultaneous liquid chromatography–tandem mass spectrometry method was developed and validated for quantification of ethinyl estradiol and levonorgestrel. The analytes were extracted with methyl-tert-butyl ether: n-hexane (50:50, v/v solvent mixture, followed by dansyl derivatization. The chromatographic separation was performed on a Kinetex C18 (50 mm×4.6 mm, 2.6 µm column with a mobile phase of 0.1% (v/v formic acid in water and acetonitrile in gradient composition. The mass transitions were monitored in electrospray positive ionization mode. The assay exhibited a linear range of 0.100–20.0 ng/mL for levonorgestrel and 4.00–500 pg/mL for ethinyl estradiol in human plasma. A run time of 9.0 min for each sample made it possible to analyze a throughput of more than 100 samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic and bioequivalence studies. Keywords: Ethinyl estradiol, Levonorgestrel, LC–MS/MS, Human plasma, Derivatization

  4. Analysis of amino acids by HPLC/electrospray negative ion tandem mass spectrometry using 9-fluorenylmethoxycarbonyl chloride (Fmoc-Cl) derivatization.

    Science.gov (United States)

    Ziegler, Jörg; Abel, Steffen

    2014-12-01

    A new method for the determination of amino acids is presented. It combines established methods for the derivatization of primary and secondary amino groups with 9-fluorenylmethoxycarbonyl chloride (Fmoc-Cl) with the subsequent amino acid specific detection of the derivatives by LC-ESI-MS/MS using multiple reaction monitoring (MRM). The derivatization proceeds within 5 min, and the resulting amino acid derivatives can be rapidly purified from matrix by solid-phase extraction (SPE) on HR-X resin and separated by reversed-phase HPLC. The Fmoc derivatives yield several amino acid specific fragment ions which opened the possibility to select amino acid specific MRM transitions. The method was applied to all 20 proteinogenic amino acids, and the quantification was performed using L-norvaline as standard. A limit of detection as low as 1 fmol/µl with a linear range of up to 125 pmol/µl could be obtained. Intraday and interday precisions were lower than 10 % relative standard deviations for most of the amino acids. Quantification using L-norvaline as internal standard gave very similar results compared to the quantification using deuterated amino acid as internal standards. Using this protocol, it was possible to record the amino acid profiles of only a single root from Arabidopsis thaliana seedlings and to compare it with the amino acid profiles of 20 dissected root meristems (200 μm).

  5. Extractionless GC/MS analysis of gamma-hydroxybutyrate and gamma-butyrolactone with trifluoroacetic anhydride and heptafluoro-1-butanol from aqueous samples.

    Science.gov (United States)

    Sabucedo, Alberto J; Furton, Kenneth G

    2004-06-01

    gamma-Hydroxybutyrate (GHB) is a DEA Schedule I drug of abuse commonly spiked into beverages to incapacitate victims of sexual assault. GHB is a challenging drug for analysis by GC/MS because of its small size, charged nature, low volatility, and intramolecular esterification leading to gamma-butyrolactone (GBL). In this work an extractionless technique has been developed that allows for the use of an aqueous sample for direct derivatization. The technique uses a solution of trifluoroacetic anhydride (TFAA) and 2,2,3,3,4,4,4-heptafluoro-1-butanol (HFB) to derivatize the active hydrogens of GHB. The conversion of GBL into GHB can be forced under alkaline conditions by diluting the sample in 10 mM borate buffer, pH 12. GBL found in beverages intended for human consumption is treated as a Schedule I control substance analogue. Spikes of the two compounds into several beverage matrices gave quantitative recovery of GHB by GC/MS. The derivatization produces higher molecular mass products whose fragmentation pattern provides multiple peaks for confirmation and quantification. The concentration of GBL can also be indirectly determined by the method developed. Therefore, this extractionless technique is rapid, sensitive, and selective for the confirmation of the presence of GHB and GBL in commercial beverages.

  6. Determination of Endocrine Disrupting Compounds in surface waters by means of chromatographic techniques coupled to mass spectrometry

    Directory of Open Access Journals (Sweden)

    M. Di Carro

    2011-01-01

    Full Text Available Two analytical methods were developed to study five endocrine disrupting compounds (4-n-nonylphenol, bisphenol A, estrone, 17β-estradiol and 17α-ethinylestradiol in waters. One method includes a fast liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS-MS analysis, while the second comprise a Stir Bar Sorptive Extraction (SBSE followed by a headspace derivatization and gaschromatography-mass spectrometry (GC-MS analysis. Passive samplers POCIS (Polar Organic Chemical Integrative Samplers were used as sampling and preconcentration steps in order to reach the very low levels of the analytes in environmental waters. Both methods were then applied to the determination of the analytes in different water samples.

  7. Gas chromatographic-mass spectrometric analysis of biomarkers related to folate and cobalamin status in human serum after dimercaptopropanesulfonate reduction and heptafluorobutyl chloroformate derivatization

    Czech Academy of Sciences Publication Activity Database

    Šimek, Petr; Hušek, Petr; Zahradníčková, Helena

    2008-01-01

    Roč. 80, č. 15 (2008), s. 5776-5782 ISSN 0003-2700 R&D Projects: GA ČR GA303/06/1674 Institutional research plan: CEZ:AV0Z50070508 Keywords : biomarkers * gas chromatographic * chloroformate derivatization Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 5.712, year: 2008

  8. Mass thickness measurement of dual-sample by dual-energy X-rays

    International Nuclear Information System (INIS)

    Chen Mincong; Li Hongmei; Chen Ziyu; Shen Ji

    2008-01-01

    X-ray equivalent energy can be used to measure mass thicknesses of materials. Based on this, a method of mass thickness measurement of dual-sample was discussed. It was found that in the range of sample mass thickness under investigation, the equivalent mass attenuation coefficient of a component could be used to compute mass thicknesses of a dual-sample, with relative errors of less than 5%. Mass thickness measurement of a fish sample was performed, and the fish bone and flesh could be displayed separately and clearly by their own mass thicknesses. This indicates that the method is effective in mass thickness measurement of dual-sample of suitable thicknesses. (authors)

  9. Microbial metabolomics with gas chromatography/mass spectrometry

    NARCIS (Netherlands)

    Koek, M.M.; Muilwijk, B.; Werf, M.J. van der; Hankemeier, T.

    2006-01-01

    An analytical method was set up suitable for the analysis of microbial metabolomes, consisting of an oximation and silylation derivatization reaction and subsequent analysis by gas chromatography coupled to mass spectrometry. Microbial matrixes contain many compounds that potentially interfere with

  10. Microwave-assisted Derivatization of Fatty Acids for Its Measurement in Milk Using High-Performance Liquid Chromatography.

    Science.gov (United States)

    Shrestha, Rojeet; Miura, Yusuke; Hirano, Ken-Ichi; Chen, Zhen; Okabe, Hiroaki; Chiba, Hitoshi; Hui, Shu-Ping

    2018-01-01

    Fatty acid (FA) profiling of milk has important applications in human health and nutrition. Conventional methods for the saponification and derivatization of FA are time-consuming and laborious. We aimed to develop a simple, rapid, and economical method for the determination of FA in milk. We applied a beneficial approach of microwave-assisted saponification (MAS) of milk fats and microwave-assisted derivatization (MAD) of FA to its hydrazides, integrated with HPLC-based analysis. The optimal conditions for MAS and MAD were determined. Microwave irradiation significantly reduced the sample preparation time from 80 min in the conventional method to less than 3 min. We used three internal standards for the measurement of short-, medium- and long-chain FA. The proposed method showed satisfactory analytical sensitivity, recovery and reproducibility. There was a significant correlation in the milk FA concentrations between the proposed and conventional methods. Being quick, economic, and convenient, the proposed method for the milk FA measurement can be substitute for the convention method.

  11. Analysis of amino acid and monoamine neurotransmitters and their metabolites in rat urine of Alzheimer's disease using in situ ultrasound-assisted derivatization dispersive liquid-liquid microextraction with UHPLC-MS/MS.

    Science.gov (United States)

    Zhao, Xian-En; He, Yongrui; Li, Meng; Chen, Guang; Wei, Na; Wang, Xiao; Sun, Jing; Zhu, Shuyun; You, Jinmao

    2017-02-20

    Neurotransmitters (NTs) may play an important role in neurodegenerative disorders such as Alzheimer's disease (AD). In order to investigate the potential links, a new simple, fast, accurate and sensitive analytical method, based on in situ ultrasound-assisted derivatization dispersive liquid-liquid microextraction (in situ UA-DDLLME) coupled with ultra high-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS), has been developed and validated. The quantitation of amino acid neurotransmitters (AANTs) and monoamine neurotransmitters (MANTs) in urine of AD rats were performed in this work. The in situ UA-DDLLME procedure involved the rapid injection of the mixture of low toxic 4-bromoanisole (extractant) and acetonitrile (dispersant), which containing the new designed and synthesized 4'-carbonyl chloride rosamine (CCR) as derivatization reagent, into the aqueous phase of real sample and buffer. Under the selected conditions, the derivatization and microextraction of analytes were simultaneously completed within 1min. Good linearity for each analyte (R>0.992) was observed with low limit of detections (LODs, S/N>3). Moreover, the proposed method was compared with direct detection or other reported methods, and the results showed that low matrix effects and good recoveries results were obtained in this work. Taken together, in situ UA-DDLLME coupled with UHPLC-MS/MS analysis was demonstrated to be a good method for sensitive, accurate and simultaneous monitoring of AANTs and MANTs. This method would be expected to be highly useful in AD diseases' clinical diagnostics and may have potential value in monitoring the efficacy of treatment. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. [Sample preparation and bioanalysis in mass spectrometry].

    Science.gov (United States)

    Bourgogne, Emmanuel; Wagner, Michel

    2015-01-01

    The quantitative analysis of compounds of clinical interest of low molecular weight (sample preparation. Sample preparation is a crucial part of chemical/biological analysis and in a sense is considered the bottleneck of the whole analytical process. The main objectives of sample preparation are the removal of potential interferences, analyte preconcentration, and converting (if needed) the analyte into a more suitable form for detection or separation. Without chromatographic separation, endogenous compounds, co-eluted products may affect a quantitative method in mass spectrometry performance. This work focuses on three distinct parts. First, quantitative bioanalysis will be defined, different matrices and sample preparation techniques currently used in bioanalysis by mass spectrometry of/for small molecules of clinical interest in biological fluids. In a second step the goals of sample preparation will be described. Finally, in a third step, sample preparation strategies will be made either directly ("dilute and shoot") or after precipitation.

  13. Rapid fingerprinting of sterols and related compounds in vegetable and animal oils and phytosterol enriched- margarines by transmission mode direct analysis in real time mass spectrometry.

    Science.gov (United States)

    Alberici, Rosana M; Fernandes, Gabriel D; Porcari, Andréia M; Eberlin, Marcos N; Barrera-Arellano, Daniel; Fernández, Facundo M

    2016-11-15

    Plant-derived sterols, often referred to as phytosterols, are important constituents of plant membranes where they assist in maintaining phospholipid bilayer stability. Consumption of phytosterols has been suggested to positively affect human health by reducing cholesterol levels in blood via inhibition of its absorption in the small intestine, thus protecting against heart attack and stroke. Sterols are challenging analytes for mass spectrometry, since their low polarity makes them difficult to ionize by both electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI), typically requiring derivatization steps to overcome their low ionization efficiencies. We present a fast and reliable method to characterize the composition of phytosterols in vegetable oils and enriched margarines. The method requires no derivatization steps or sample extraction procedures thanks to the use of transmission mode direct analysis in real time mass spectrometry (TM-DART-MS). Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Photoreactive polymer brushes for high-density patterned surface derivatization using a Diels-Alder photoclick reaction.

    Science.gov (United States)

    Arumugam, Selvanathan; Orski, Sara V; Locklin, Jason; Popik, Vladimir V

    2012-01-11

    Reactive polymer brushes grown on silicon oxide surfaces were derivatized with photoreactive 3-(hydroxymethyl)naphthalene-2-ol (NQMP) moieties. Upon 300 or 350 nm irradiation, NQMP efficiently produces o-naphthoquinone methide (oNQM), which in turn undergoes very rapid Diels-Alder addition to vinyl ether groups attached to a substrate, resulting in the covalent immobilization of the latter. Any unreacted oNQM groups rapidly add water to regenerate NQMP. High-resolution surface patterning is achieved by irradiating NQMP-derivatized surfaces using photolithographic methods. The Diels-Alder photoclick reaction is orthogonal to azide-alkyne click chemistry, enabling sequential photoclick/azide-click derivatizations to generate complex surface functionalities. © 2011 American Chemical Society

  15. A sensitive and selective quantification of catecholamine neurotransmitters in rat microdialysates by pre-column dansyl chloride derivatization using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Nirogi, Ramakrishna; Komarneni, Prashanth; Kandikere, Vishwottam; Boggavarapu, Rajeshkumar; Bhyrapuneni, Gopinadh; Benade, Vijay; Gorentla, Srinivasarao

    2013-01-15

    A rapid and sensitive liquid chromatography tandem mass spectrometry method for simultaneous quantification of catecholamine neurotransmitters in microdialysates was developed. The catecholamine neurotransmitters dopamine (DA) and norepinephrine (NE) were pre-column derivatized with dansyl chloride and analyzed. A gradient elution method was used to separate the analytes from the interferences on an Agilent Poroshell 120 EC-C18 outer porous micro particulate column. The method was robust and sensitive to determine with the lower limit of quantification value of 0.068pmol/mL and 0.059pmol/mL for DA and NE, respectively. It has acceptable precision and accuracy for concentrations over the standard curve range. The method was successfully applied for simultaneous quantitation of DA and NE in the prefrontal cortex (PFC) dialysates of rats obtained from a microdialysis study dosed with vehicle and atomoxetine through intra peritoneal (i.p.) route at a dose of 3mg/kg to monitor the change in extracellular concentrations. Thus, accomplishment of this method would facilitate the neurochemical monitoring for discovery of new chemical entities targeted for the treatment of attention deficit hyperactivity disorder (ADHD). Copyright © 2012. Published by Elsevier B.V.

  16. Quantitation of total homocysteine in human plasma by derivatization to its N(O,S)-propoxycarbonyl propyl ester and gas chromatography-mass spectrometry analysis.

    Science.gov (United States)

    Sass, J O; Endres, W

    1997-08-01

    Much evidence supports the hypothesis that mild or moderate hyperhomocysteinaemia represents an important and independent risk factor for occlusive vascular diseases. Therefore, the accurate and reliable determination of total plasma homocysteine has gained major importance for risk assessment. Furthermore, it can help in the detection of folate and vitamin B12 deficiency. This has prompted us to develop a sensitive gas chromatography-mass spectrometry (GC-MS) method in order to quantify total homocysteine in human plasma. Prior to chromatography, reduced homocysteine was released from disulfide bonds by incubation with excess dithiothreitol and converted into its N(O,S)-propoxycarbonyl propyl ester by derivatization with n-propyl chloroformate. Aminoethylcysteine served as internal standard. The method proved to be highly linear over the entire concentration range examined (corresponding to 0-266 microM homocysteine) and showed intra-assay and inter-assay variation (relative standard deviations) of approximately 5 and 5-10%, respectively. External quality control by comparison with duplicate analysis performed on a HPLC-based system revealed satisfactory correlation. The newly developed GC-MS based method provides simple, reliable and fast quantification of total homocysteine and requires only inexpensive chemicals, which are easy to obtain.

  17. Simultaneous speciation of mercury and butyltin compounds in natural waters and snow by propylation and species-specific isotope dilution mass spectrometry analysis

    Energy Technology Data Exchange (ETDEWEB)

    Monperrus, M.; Tessier, E.; Veschambre, S.; Amouroux, D.; Donard, O. [Universite de Pau et des Pays de L' Adour, Laboratoire de Chimie Analytique Bio-inorganique et Environnement, CNRS UMR 5034, Helioparc, Pau (France)

    2005-02-01

    A robust method has been developed for simultaneous determination of mercury and butyltin compounds in aqueous samples. This method is capable of providing accurate results for analyte concentrations in the picogram per liter to nanogram per liter range. The simultaneous determination of the mercury and tin compounds is achieved by species-specific isotope dilution, derivatization, and gas chromatography-inductively coupled plasma mass spectrometer (GC-ICP-MS). In derivatization by ethylation and propylation, reaction conditions such as pH and the effect of chloride were carefully studied. Ethylation was found to be more sensitive to matrix effects, especially for mercury compounds. Propylation was thus the preferred derivatization method for simultaneous determination of organomercury and organotin compounds in environmental samples. The analytical method is highly accurate and precise, with RSD values of 1 and 3% for analyte concentrations in the picogram per liter to nanogram per liter range. By use of cleaning procedures and SIDMS blank measurements, detection limits in the range 10-60 pg L{sup -1} were achieved; these are suitable for determination of background levels of these contaminants in environmental samples. This was demonstrated by using the method for analysis of real snow and seawater samples. This work illustrates the great advantage of species-specific isotope dilution for the validation of an analytical speciation method - the possibility of overcoming species transformations and non-quantitative recovery. Analysis time is saved by use of the simultaneous method, because of the use of a single sample-preparation procedure and one analysis. (orig.)

  18. Rapid Determination of Clenbuterol in Pork by Direct Immersion Solid-Phase Microextraction Coupled with Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Ye, Diru; Wu, Susu; Xu, Jianqiao; Jiang, Ruifen; Zhu, Fang; Ouyang, Gangfeng

    2016-02-01

    Direct immersion solid-phase microextraction (DI-SPME) coupled with gas chromatography-mass spectrometry (GC-MS) was developed for rapid analysis of clenbuterol in pork for the first time. In this work, a low-cost homemade 44 µm polydimethylsiloxane (PDMS) SPME fiber was employed to extract clenbuterol in pork. After extraction, derivatization was performed by suspending the fiber in the headspace of the 2 mL sample vial saturated with a vapor of 100 µL hexamethyldisilazane. Lastly, the fiber was directly introduced to GC-MS for analysis. All parameters that influenced absorption (extraction time), derivatization (derivatization reagent, time and temperature) and desorption (desorption time) were optimized. Under optimized conditions, the method offered a wide linear range (10-1000 ng g(-1)) and a low detection limit (3.6 ng g(-1)). Finally, the method was successfully applied in the analysis of pork from the market, and recoveries of the method for spiked pork were 97.4-105.7%. Compared with the traditional solvent extraction method, the proposed method was much cheaper and fast. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Derivatizations for improved detection of alcohols by gas chromatography and photoionization detection (GC-PID)

    International Nuclear Information System (INIS)

    Krull, I.S.; Swartz, M.; Driscoll, J.N.

    1984-01-01

    Pentafluorophenyldimethylsilyl chloride (flophemesyl chloride, Fl) is a well known derivatization reagent for improved electron capture detection (ECD) in gas chromatography (GC)(GC-ECD), but it has never been utilized for improved detectability and sensitivity in GC-photoionization detection (GC-PID). A wide variety of flophemesyl alcohol derivatives have been used in order to show a new approach for realizing greatly reduced minimum detection limits (MDL) of virtually all alcohol derivatives in GC-PID analysis. This particular derivatization approach is inexpensive and easy to apply, leading to quantitative or near 100% conversion of the starting alcohols to the expected flophemesyl ethers (silyl ethers). Detection limits can be lowered by 2-3 orders of magnitude for such derivatives when compared with the starting alcohols, along with calibration plots that are linear over 5-7 orders of magnitude. Specific GC conditions have been developed for many flophemesyl derivatives, in all cases using packed columns. Both ECD and PID relative response factors (RRFs) and normalized RRFs have been determined, and such ratios can now be used for improved analytic identification from complex sample matrices, where appropriate. 28 references, 2 figures, 5 tables

  20. Patterns of proteolytic cleavage and carbodiimide derivatization in sarcoplasmic reticulum adenosinetriphosphatase

    International Nuclear Information System (INIS)

    de Ancos, J.G.; Inesi, G.

    1988-01-01

    Two series of experiments were carried out to characterize (a) peptide fragments of sarcoplasmic reticulum (SR) ATPase, based on proteolysis with different enzymes and distribution of known labels, and (b) specific labeling and functional inactivation patterns, following ATPase derivatization with dicyclohexylcarbodiimide (DCCD) under various conditions. Digestion with trypsin or chymotrypsin results in the initial cleavage of the SR ATPase in two fragments of similar size and then into smaller fragments, while subtilisin and thermolysin immediately yield smaller fragments. Peptide fragments were assigned to segments of the protein primary structure and to functionally relevant domains, such as those containing the 32 P at the active site and the fluorescein isothiocyanate at the nucleotide site. ATPase derivatization with [ 14 C]DCCD under mild conditions produced selective inhibition of ATPase hydrolytic catalysis without significant incorporation of the 14 C radioactive label. This effect is attributed to blockage of catalytically active residues by reaction of the initial DCCD adduct with endogenous or exogenous nucleophiles. ATPase derivatization with [ 14 C]DCCD under more drastic conditions produced inhibition of calcium binding, 14 C radioactive labeling of tryptic fragments A 1 and A 2 (but not of B), and extensive cross-linking. The presence of calcium during derivatization prevented functional inactivation, radioactive labeling of fragment A 2 , and internal cross-linking of fragment A 1 . It is proposed that both A 1 and A 2 fragments participate in formation of the calcium binding domain and that the labeled residues of fragment A 2 are directly involved in calcium complexation. A diagram is constructed, representing the relative positions of labels and functional domains within the ATPase protein

  1. Accurate EPR radiosensitivity calibration using small sample masses

    Science.gov (United States)

    Hayes, R. B.; Haskell, E. H.; Barrus, J. K.; Kenner, G. H.; Romanyukha, A. A.

    2000-03-01

    We demonstrate a procedure in retrospective EPR dosimetry which allows for virtually nondestructive sample evaluation in terms of sample irradiations. For this procedure to work, it is shown that corrections must be made for cavity response characteristics when using variable mass samples. Likewise, methods are employed to correct for empty tube signals, sample anisotropy and frequency drift while considering the effects of dose distribution optimization. A demonstration of the method's utility is given by comparing sample portions evaluated using both the described methodology and standard full sample additive dose techniques. The samples used in this study are tooth enamel from teeth removed during routine dental care. We show that by making all the recommended corrections, very small masses can be both accurately measured and correlated with measurements of other samples. Some issues relating to dose distribution optimization are also addressed.

  2. Accurate EPR radiosensitivity calibration using small sample masses

    International Nuclear Information System (INIS)

    Hayes, R.B.; Haskell, E.H.; Barrus, J.K.; Kenner, G.H.; Romanyukha, A.A.

    2000-01-01

    We demonstrate a procedure in retrospective EPR dosimetry which allows for virtually nondestructive sample evaluation in terms of sample irradiations. For this procedure to work, it is shown that corrections must be made for cavity response characteristics when using variable mass samples. Likewise, methods are employed to correct for empty tube signals, sample anisotropy and frequency drift while considering the effects of dose distribution optimization. A demonstration of the method's utility is given by comparing sample portions evaluated using both the described methodology and standard full sample additive dose techniques. The samples used in this study are tooth enamel from teeth removed during routine dental care. We show that by making all the recommended corrections, very small masses can be both accurately measured and correlated with measurements of other samples. Some issues relating to dose distribution optimization are also addressed

  3. Selenium Derivatization of Nucleic Acids for Phase and Structure Determination in Nucleic Acid X-ray Crystallography

    Directory of Open Access Journals (Sweden)

    Zhen Huang

    2008-03-01

    Full Text Available Selenium derivatization (via selenomethionine of proteins for crystal structure determination via MAD phasing has revolutionized protein X-ray crystallography. It is estimated that over two thirds of all new crystal structures of proteins have been determined via Se-Met derivatization. Similarly, selenium functionalities have also been successfully incorporated into nucleic acids to facilitate their structure studies and it has been proved that this Se-derivatization has advantages over halogen strategy, which was usually used as a traditional method in this field. This review reports the development of site-specific selenium derivatization of nucleic acids for phase determination since the year of 2001 (mainly focus on the 2’-position of the ribose. All the synthesis of 2’-SeMe modified phosphoramidite building blocks (U, C, T, A, G and the according oligonucleotides are included. In addition, several structures of selenium contained nucleic acid are also described in this paper.

  4. Surface functional group characterization using chemical derivatization X-ray photoelectron spectroscopy (CD-XPS)

    Energy Technology Data Exchange (ETDEWEB)

    Jagst, Eda

    2011-03-18

    Chemical derivatization - X-ray photolectron spectroscopy (CD-XPS) was applied successfully in order to determine different functional groups on thin film surfaces. Different amino group carrying surfaces, prepared by spin coating, self-assembly and plasma polymerization, were successfully investigated by (XPS) and near edge X-ray absorption fine structure (NEXAFS) spectroscopy. Amino groups were derivatized with the widely used primary amino group tags, pentafluorobenzaldehyde (PFB) and 4-(trifluoromethyl)-benzaldehyde (TFBA), prior to analysis. Primary amino group quantification was then carried out according to the spectroscopical data. Self-assembled monolayers (SAMs) of different terminal groups were prepared and investigated with XPS and spectra were compared with reference surfaces. An angle resolved NEXAFS measurement was applied to determine the orientation of SAMs. Plasma polymerized allylamine samples with different duty cycle, power and pressure values were prepared in order to study the effects of external plasma parameters on the primary amino group retention. CD-XPS was used to quantify the amino groups and experiments show, that the milder plasma conditions promote the retention of amino groups originating from the allylamine monomer. An interlaboratory comparison of OH group determination on plasma surfaces of polypropylene treated with oxygen plasma, was studied. The surfaces were investigated with XPS and the [OH] amount on the surfaces was calculated. (orig.)

  5. An improved reference measurement procedure for triglycerides and total glycerides in human serum by isotope dilution gas chromatography-mass spectrometry.

    Science.gov (United States)

    Chen, Yizhao; Liu, Qinde; Yong, Sharon; Teo, Hui Ling; Lee, Tong Kooi

    2014-01-20

    Triglycerides are widely tested in clinical laboratories using enzymatic methods for lipid profiling. As enzymatic methods can be affected by interferences from biological samples, this together with the non-specific nature of triglycerides measurement makes it necessary to verify the accuracy of the test results with a reference measurement procedure. Several such measurement procedures had been published. These procedures generally involved lengthy and laborious sample preparation steps. In this paper, an improved reference measurement procedure for triglycerides and total glycerides was reported which simplifies the sample preparation steps and greatly shortens the time taken. The procedure was based on isotope dilution gas chromatography-mass spectrometry (IDGC-MS)with tripalmitin as the calibration standard. Serum samples were first spiked with isotope-labeled tripalmitin. For the measurement of triglycerides, the serum samples were subjected to lipid extraction followed by separation of triglycerides from diglycerides and monoglycerides. Triglycerides were then hydrolyzed to glycerol, derivatized and injected into the GC–MS for quantification. For the measurement of total glycerides, the serum samples were hydrolyzed directly and derivatized before injection into the GC-MS for quantification. All measurement results showed good precision with CV triglycerides and total glycerides were well within the certified ranges of the CRM, with deviation triglycerides and total glycerides.

  6. Validation of a confirmatory method for the determination of melamine in egg by gas chromatography-mass spectrometry and ultra-performance liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Xia Xi; Ding Shuangyang; Li Xiaowei; Gong Xiao; Zhang Suxia; Jiang Haiyang; Li Jiancheng; Shen Jianzhong

    2009-01-01

    A sensitive and reliable method was developed and validated for detection and confirmation of melamine in egg based on gas chromatography-mass spectrometry (GC-MS) and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Trichloroacetic acid solution was used for sample extraction and precipitation of proteins. The aqueous extracts were subjected to solid-phase extraction by mixed-mode reversed-phase/strong cation-exchange cartridges. Using ultra-performance liquid chromatography and electrospray ionization in the positive ion mode, melamine was determined by LC-MS/MS, which was completed in 5 min for each injection. For the GC-MS analysis, extracted melamine was derivatized with N,O-bis(trimethylsilyl)trifluoracetamide prior to selected ion monitoring detection in electron impact mode. The average recovery of melamine from fortified samples ranged from 85.2% to 103.2%, with coefficients of variation lower than 12%. The limit of detection obtained by GC-MS and UPLC-MS/MS was 10 and 5 μg kg -1 , respectively. This validated method was successfully applied to the determination of melamine in real samples from market.

  7. [Determination of formaldehyde and acetaldehyde in packaging paper by dansylhydrazine derivatization-high performance liquid chromatography-fluorescence detection].

    Science.gov (United States)

    Gong, Shuguo; Liang, Yong; Tang, Liyun; Huang, Ping; Dai, Yunhui

    2017-07-08

    A high performance liquid chromatography with fluorescence detection (HPLC-FLD) method was developed for the simultaneous determination of formaldehyde and acetaldehyde in packaging paper by dansylhydrazine (DNSH) derivatization. The samples were extracted by derivatization reagent for 30 min, and derived for 24 h. After purifying treatment with a PSA/C18 cartridge, a Diamonsil ® C18 column (150 mm×4.6 mm, 5 μ m) was used as stationary phase for separation, the mixtures of acetic acid aqueous solution (pH 2.55)-acetonitrile were used as mobile phases by gradient elution, and the excitation and emission wavelengths were 330 nm and 484 nm, respectively. The results showed that the recoveries of formaldehyde and acetaldehyde spiked in the samples were 81.64%-106.78%, and the relative standard deviations (RSDs) were 2.02%-5.53% ( n =5). The limits of detection of formaldehyde and acetaldehyde were 19.2 μ g/kg and 20.7 μ g/kg, respectively. The limits of quantification of formaldehyde and acetaldehyde were 63.9 μ g/kg and 69.1 μ g/kg, respectively. The method is simple, sensitive and reproducible. It provides a basic approach for the determination of trace formaldehyde and acetaldehyde.

  8. [Determination of urea in canned foods by high performance liquid chromatography-fluorescence detection coupled with precolumn derivatization].

    Science.gov (United States)

    Zeng, Qi; Zhang, Jin; Xu, Dunming; Zhang, Zhigang; Ke, Zhicheng

    2015-01-01

    A method for the determination of urea residue in canned foods by high performance liquid chromatography-fluorescence detection (HPLC-FLD) coupled with precolumn derivatization was established. The sample (5.0 g), including canned edible fungi, fruit, vegetable, fish, and meat was extracted with 20 mL 1% (v/v) acetic acid solution. The extract was centrifuged, filtrated, and then derivatized with xanthydrol. The analysis was completed with HPLC-FLD. A good linear relationship was obtained in the range of 0.1-500 mg/L with the correlation coefficients more than 0.9995. The average recoveries of urea spiked at 0.001-30 g/kg levels in five kinds of canned foods ranged from 80.2% to 109.7% with the RSDs of 2.05%-6.53%. The limit of detection (LOD) was 0.5 mg/kg, and the limit of quantitation (LOQ) was 1.0 mg/kg. The proposed procedure was then applied to the analysis of 168 real samples collected from Xiamen, Fujian Province, China. The existence of urea was found in three pork cans with contents of 10.6, 62.1 and 2.6 mg/kg, respectively. The method is stable, reliable, simple and suitable for the determination of urea in canned foods, and has great potential for routine analysis in foodstuffs.

  9. Surface Structures Formed by a Copper(II Complex of Alkyl-Derivatized Indigo

    Directory of Open Access Journals (Sweden)

    Akinori Honda

    2016-10-01

    Full Text Available Assembled structures of dyes have great influence on their coloring function. For example, metal ions added in the dyeing process are known to prevent fading of color. Thus, we have investigated the influence of an addition of copper(II ion on the surface structure of alkyl-derivatized indigo. Scanning tunneling microscope (STM analysis revealed that the copper(II complexes of indigo formed orderly lamellar structures on a HOPG substrate. These lamellar structures of the complexes are found to be more stable than those of alkyl-derivatized indigos alone. Furthermore, 2D chirality was observed.

  10. A Validated Stability-indicating Reverse Phase HPLC Assay Method for the Determination of Memantine Hydrochloride Drug Substance with UV-Detection Using Precolumn Derivatization Technique

    Directory of Open Access Journals (Sweden)

    Bhavil Narola

    2010-01-01

    Full Text Available This present paper deals with the development and validation of a stability indicating high performance liquid chromatographic method for the quantitative determination of Memantine hydrochloride. Memantine hydrochloride was derivatized with 0.015 M 9-fluorenylmethyl chloroformate (FMOC and 0.5 M borate buffer solution by keeping it at room temperature for about 20 minutes and the chromatographic separation achieved by injecting 10 μL of the derivatized mixture into a Waters HPLC system with photodiode array detector using a kromasil C18 column (150 × 4.6 mm, 5 μ, The mobile phase consisting of 80% acetonitrile and 20% phosphate buffer solution and a flow rate of 2 milliliter/minute. The Memantine was eluted at approximately 7.5 minutes. The volume of FMOC used in derivatization, concentration of FMOC and derivatization time was optimized and used. Forced degradation studies were performed on bulk sample of Memantine hydrochloride using acid (5.0 Normal (N hydrochloric acid, base (1.0 N sodium hydroxide, oxidation (30% hydrogen peroxide, thermal (105 ° C, photolytic and humidity conditions. The developed LC method was validated with respect to specificity, precision (% RSD about 0.70%, linearity (linearity of range about 70-130 μg/mL, ruggedness (Overall % RSD about 0.35%, stability in analytical solution (Cumulative % RSD about 0.11% after 1450 min. and robustness.

  11. A Validated Stability-indicating Reverse Phase HPLC Assay Method for the Determination of Memantine Hydrochloride Drug Substance with UV-Detection Using Precolumn Derivatization Technique

    Directory of Open Access Journals (Sweden)

    Bhavil Narola

    2010-07-01

    Full Text Available This present paper deals with the development and validation of a stability indicating high performance liquid chromatographic method for the quantitative determination of Memantine hydrochloride. Memantine hydrochloride was derivatized with 0.015 M 9-fluorenylmethyl chloroformate (FMOC and 0.5 M borate buffer solution by keeping it at room temperature for about 20 minutes and the chromatographic separation achieved by injecting 10 µL of the derivatized mixture into a Waters HPLC system with photodiode array detector using a kromasil C18 column (150 × 4.6 mm, 5 µ. The mobile phase consisting of 80% acetonitrile and 20% phosphate buffer solution and a flow rate of 2 milliliter/minute. The Memantine was eluted at approximately 7.5 minutes. The volume of FMOC used in derivatization, concentration of FMOC and derivatization time was optimized and used. Forced degradation studies were performed on bulk sample of Memantine hydrochloride using acid (5.0 Normal (N hydrochloric acid, base (1.0 N sodium hydroxide, oxidation (30% hydrogen peroxide, thermal (105°C, photolytic and humidity conditions. The developed LC method was validated with respect to specificity, precision (% RSD about 0.70%, linearity (linearity of range about 70–130 µg/mL, ruggedness (Overall % RSD about 0.35%, stability in analytical solution (Cumulative % RSD about 0.11% after 1450 min. and robustness.

  12. Determination of ammonium in aqueous samples using new headspace dynamic in-syringe liquid-phase microextraction with in situ derivitazation coupled with liquid chromatography-fluorescence detection.

    Science.gov (United States)

    Muniraj, Sarangapani; Yan, Cheing-Tong; Shih, Hou-Kung; Ponnusamy, Vinoth Kumar; Jen, Jen-Fon

    2012-11-19

    A new simultaneous derivatization and extraction method for the preconcentration of ammonia using new one-step headspace dynamic in-syringe liquid-phase microextraction with in situ derivatization was developed for the trace determination of ammonium in aqueous samples by liquid chromatography with fluorescence detection (LC-FLD). The acceptor phase (as derivatization reagent) containing o-phthaldehyde and sodium sulfite was held within a syringe barrel and immersed in the headspace of sample container. The gaseous ammonia from the alkalized aqueous sample formed a stable isoindole derivative with the acceptor phase inside the syringe barrel through the reciprocated movements of plunger. After derivatization-cum-extraction, the acceptor phase was directly injected into LC-FLD for analysis. Parameters affecting the ammonia evolution and the extraction/derivatization efficiency such as sample matrix, pH, temperature, sampling time, and the composition of derivatization reagent, reaction temperature, and frequency of reciprocated plunger, were studied thoroughly. Results indicated that the maximum extraction efficiency was obtained by using 100μL derivatization reagent in a 1-mL gastight syringe under 8 reciprocated movements of plunger per min to extract ammonia evolved from a 20mL alkalized aqueous solution at 70°C (preheated 4min) with 380rpm stirring for 8min. The detection was linear in the concentration range of 0.625-10μM with the correlation coefficient of 0.9967 and detection limit of 0.33μM (5.6ng mL(-1)) based on SN(-1)=3. The method was applied successfully to determine ammonium in real water samples without any prior cleanup of the samples, and has been proved to be a simple, sensitive, efficient and cost-effective procedure for trace ammonium determination in aqueous samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. A simple one-step ultrasonic-assisted extraction and derivatization method coupling to high-performance liquid chromatographyfor the determination of ε-aminocaproic acid and amino acids in cosmetics.

    Science.gov (United States)

    Du, Yuanqi; Xia, Ling; Xiao, Xiaohua; Li, Gongke; Chen, Xiaoguang

    2018-06-15

    Nowadays, the safety of cosmetics is a widespread concern. Amines are common cosmetic additives. Some of them such as amino acids are beneficial. Another kind of amines, however, ε-aminocaproic acid (EACA) is prohibited to add into cosmetics for its adverse reactions. In this study, a simple, rapid, sensitive and eco-friendly one-step ultrasonic-assisted extraction and derivatization (UAE-D) method was developed for determination of EACA and amino acids in cosmetics by coupling with high-performance liquid chromatography (HPLC). By using this sample preparation method, extraction and derivatization of EACA and amino acids were finished in one step in ultrasound field. During this procedure, 4-fluoro-7-nitrobenzofurazan (NBD-F)was applied as derivatization reagent. The extraction conditions including the amount of NBD-F, extraction and derivatization temperature, the ultrasonic vibration time and pH value of the aqueous phase were evaluated. Meanwhile, the extraction mechanism was investigated. Under optimized conditions, the method detection limits were 0.086-0.15 μg/L, and method quantitation limits were 0.29-0.47 μg/L with RSDs less than 3.7% (n = 3). The recoveries of EACA and amino acids obtained from cosmetic samples were in range from 76.9% to 122.3%. Amino acids were found in all selected samples and quantified in range from 1.9 ± 0.9 to 677.2 ± 17.9 μg/kg. And EACA was found and quantified with the contents of 1284.3 ± 22.1 μg/kg in a toner sample. This UAE-D-HPLC method shortened and simplified the sample pretreatment as well as enhanced the sensitivity of analytical method. In our record, only 10 min was needed for the total sample preparation process. And the method detection limits were two orders of magnitude less than literature reports. Furthermore, we reduced the consumption of solvent and minimized the usage of organic solvents, which made our method moving towards green analytical chemistry. In brief, our UAE

  14. Effects of derivatization reagents consisting of n-alkyl chloroformate/n-alcohol combinations in LC-ESI-MS/MS analysis of zwitterionic antiepileptic drugs.

    Science.gov (United States)

    Kostić, Nađa; Dotsikas, Yannis; Malenović, Anđelija; Medenica, Mirjana

    2013-11-15

    In the current study, three antiepileptic drugs with zwitterionic properties, namely vigabatrin, pregabalin and gabapentin, were chosen as model analytes to undergo derivatization by applying various n-alkyl chloroformate/n-alcohol combinations, followed by LC-ESI-MS/MS analysis. The employment of 16 combinations per drug using methyl, ethyl, propyl or butyl chloroformate coupled with methanol, ethanol, propanol or butanol, greatly affected a series of parameters of the derivatives, such as retention time on C8 column, signal expressed via areas, limit of detection values, as well as the yields of the main and side reactions. Practically, even slight modification of n-alkyl group of either chloroformate or alcohol resulted in significant changes in the chromatographic and mass spectrometric behavior of the novel derivative. It was clearly demonstrated that all the estimated parameters were highly correlated with the length of n-alkyl groups of the involved chloroformate and alcohol. The most significant influence was monitored in peak area values, indicating that the length of the n-alkyl chain plays an important role in electrospray ionization efficiency. For this parameter, increasing the n-alkyl chain from methyl to butyl led to increment up to 2089%, 508.7% and 1075% for area values of derivatized vigabatrin, pregabalin and gabapentin, respectively. These changes affected also the corresponding values of limits of detection, with the estimated improvements up to 1553%, 397.7% and 875.0% for the aforementioned derivatized drugs, respectively. Besides the obvious utilization of these conclusions in the development of bioanalytical methods for these analytes with the current protocol, this study offers valuable data which can be useful in more general approaches, giving insights into the effects of this derivatization reaction and its performances. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Modified Method for Detection of Benzoylecgonine in Human Urine by GC-MS: Derivatization Using Pentafluoropropanol/Acetic Anhydride.

    Science.gov (United States)

    Serafin, Michelle C; Paulemon, Kasandra M; Fuller, Zachary J; Bronner, William E

    2017-05-01

    An existing GC-MS method for detecting benzoylecgonine (BZE) in urine was modified by changing derivatizing reagents. This method modification presents a cost-effective alternative derivatization procedure for the detection of BZE in urine by GC-MS. The combination of pentafluoropropanol and acetic anhydride was found to produce the same reaction product for BZE as pentafluoropropanol with pentafluoropropionic anhydride, while reducing reagent cost. With no anhydride present, derivatization of BZE by pentafluoropropanol did not occur. Published by Oxford University Press 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  16. Method development for the determination of 24S-hydroxycholesterol in human plasma without derivatization by high-performance liquid chromatography with tandem mass spectrometry in atmospheric pressure chemical ionization mode.

    Science.gov (United States)

    Sugimoto, Hiroshi; Kakehi, Masaaki; Satomi, Yoshinori; Kamiguchi, Hidenori; Jinno, Fumihiro

    2015-10-01

    We developed a highly sensitive and specific high-performance liquid chromatography with tandem mass spectrometry method with an atmospheric pressure chemical ionization interface to determine 24S-hydroxycholesterol, a major metabolite of cholesterol formed by cytochrome P450 family 46A1, in human plasma without any derivatization step. Phosphate buffered saline including 1% Tween 80 was used as the surrogate matrix for preparation of calibration curves and quality control samples. The saponification process to convert esterified 24S-hydroxycholesterol to free sterols was optimized, followed by liquid-liquid extraction using hexane. Chromatographic separation of 24S-hydroxycholesterol from other isobaric endogenous oxysterols was successfully achieved with gradient mobile phase comprised of 0.1% propionic acid and acetonitrile using L-column2 ODS (2 μm, 2.1 mm id × 150 mm). This assay was capable of determining 24S-hydroxycholesterol in human plasma (200 μL) ranging from 1 to 100 ng/mL with acceptable intra- and inter-day precision and accuracy. The potential risk of in vitro formation of 24S-hydroxycholesterol by oxidation from endogenous cholesterol in human plasma was found to be negligible. The stability of 24S-hydroxycholesterol in relevant solvents and human plasma was confirmed. This method was successfully applied to quantify the plasma concentrations of 24S-hydroxycholesterol in male and female volunteers. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Hydrofluoric Acid-Based Derivatization Strategy To Profile PARP-1 ADP-Ribosylation by LC-MS/MS.

    Science.gov (United States)

    Gagné, Jean-Philippe; Langelier, Marie-France; Pascal, John M; Poirier, Guy G

    2018-06-11

    Despite significant advances in the development of mass spectrometry-based methods for the identification of protein ADP-ribosylation, current protocols suffer from several drawbacks that preclude their widespread applicability. Given the intrinsic heterogeneous nature of poly(ADP-ribose), a number of strategies have been developed to generate simple derivatives for effective interrogation of protein databases and site-specific localization of the modified residues. Currently, the generation of spectral signatures indicative of ADP-ribosylation rely on chemical or enzymatic conversion of the modification to a single mass increment. Still, limitations arise from the lability of the poly(ADP-ribose) remnant during tandem mass spectrometry, the varying susceptibilities of different ADP-ribose-protein bonds to chemical hydrolysis, or the context dependence of enzyme-catalyzed reactions. Here, we present a chemical-based derivatization method applicable to the confident identification of site-specific ADP-ribosylation by conventional mass spectrometry on any targeted amino acid residue. Using PARP-1 as a model protein, we report that treatment of ADP-ribosylated peptides with hydrofluoric acid generates a specific +132 Da mass signature that corresponds to the decomposition of mono- and poly(ADP-ribosylated) peptides into ribose adducts as a consequence of the cleavage of the phosphorus-oxygen bonds.

  18. Gas chromatographic determination of purines and pyrimidines from DNA using ethyl chloroformate as derivatizing reagent

    International Nuclear Information System (INIS)

    Brohi, R.O.Z.; Khuhawar, M.Y.; Laghari, A.J.; Channa, A.

    2016-01-01

    An analytical method has been proposed for the separation and determination of guanine, adenine, cytosine, thymine and uracil by gas chromatography (GC) following precolumn derivatization using ethyl chloroformate. The GC separation was achieved from HP-5 (30 m x 0.32 rnrn id) column with layer thickness 0.25 microm. The linear calibrations were observed within 0.5-50.0 micro mole/L for each of the compound and limits of detection were within 0.1-0.17 micro mol/L. The derivatization, separation and quantitation was repeatable with intra (n=5) and inter (n=5) variation in terms of peak height/peak area and retention time with relative standard deviation (RSD) within 4.70-6.43%. The method was applied for the analysis of isolated DNA from human blood and plant leaves after acid hydrolysis. The concentration of thymine, adenine, cytosine and guanine in blood samples were observed within 0.602-2.135 micro mol/L of each compounds with RSD 2.60- 6.00%. The recovery of the nucleobases by standard addition was calculated within 98-108% with RSD 2.5-7.8%. (author)

  19. Gas Chromatographic Determination of Purines and Pyrimidines from DNA Using Ethyl Chloroformate as Derivatizing Reagent

    Directory of Open Access Journals (Sweden)

    Rafi O. Zaman Brohi

    2016-06-01

    Full Text Available An analytical method has been proposed for the separation and determination of guanine, adenine, cytosine, thymine and uracil by gas chromatography (GC following precolumn derivatization using ethyl chloroformate. The GC separation was achieved from HP-5 (30 m × 0.32 mm id column with layer thickness 0.25 µm. The linear calibrations were observed within 0.5-50.0 µmol/L for each of the compound and limits of detection were within 0.1-0.17 µmol/L. The derivatization, separation and quantitation was repeatable with intra (n=5 and inter (n=5 variation in terms of peak height/peak area and retention time with relative standard deviation (RSD within 4.70-6.43%. The method was applied for the analysis of isolated DNA from human blood and plant leaves after acid hydrolysis. The concentration of thymine, adenine, cytosine and guanine in blood samples were observed within 0.602-2.135 µmol/L of each compounds with RSD 2.60-6.00%. The recovery of the nucleobases by standard addition was calculated within 98-108% with RSD 2.5-7.8%.

  20. Separation-oriented derivatization of native fluorescent compounds through fluorous labeling followed by liquid chromatography with fluorous-phase.

    Science.gov (United States)

    Sakaguchi, Yohei; Yoshida, Hideyuki; Todoroki, Kenichiro; Nohta, Hitoshi; Yamaguchi, Masatoshi

    2009-06-15

    We have developed a new and simple method based on "fluorous derivatization" for LC of native fluorescent compounds. This method involves the use of a column with a fluorous stationary phase. Native fluorescent analytes with target functional groups are precolumn derivatized with a nonfluorescent fluorous tag, and the fluorous-labeled analytes are retained in the column, whereas underivatized substances are not. Only the retained fluorescent analytes are detected fluorometrically at appropriate retention times, and retained substrates without fluorophores are not detected. In this study, biologically important carboxylic acids (homovanillic acid, vanillylmandelic acid, and 5-hydroxyindoleacetic acid) and drugs (naproxen, felbinac, flurbiprofen, and etodolac) were used as model native fluorescent compounds. Experimental results indicate that the fluorous-phase column can selectively retain fluorous compounds including fluorous-labeled analytes on the basis of fluorous separation. We believe that separation-oriented derivatization presented here is the first step toward the introduction of fluorous derivatization in quantitative LC analysis.

  1. Trace determination of the flame retardant tetrabromobisphenol A in the atmosphere by gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Xie Zhiyong; Ebinghaus, Ralf; Lohmann, Rainer; Heemken, Olaf; Caba, Armando; Puettmann, Wilhelm

    2007-01-01

    A simple and effective method has been developed for analysis of the flame retardant tetrabromobisphenol A (TBBPA) in environmental samples by using modified soxhlet extraction in combination with silica gel clean-up, derivatization with silylation reagent and gas chromatography-mass spectrometry (GC-MS) in selected ion monitoring mode (SIM). Satisfactory recoveries were achieved for the large volume sampling, soxhlet extraction and silica gel clean-up. The overall recovery is 79 ± 1%. The derivatization procedure is simple and fast, and produces stable TBBPA derivative. GC-MS with electronic impact (EI) ionization mode shows better detection power than using negative chemical ionization (NCI) mode. EI gives a method detection limit of 0.04 pg m -3 and enables to determine trace TBBPA in ambient air in remote area. The method was successfully applied to the determination of TBBPA in atmospheric samples collected over land and coastal regions. The concentrations of TBBPA ranged from below the method detection limit (0.04 pg m -3 ) to 0.85 pg m -3 . A declining trend with increasing latitude was present from the Wadden Sea to the Arctic. The atmospheric occurrence of TBBPA in the Arctic is significant and might imply that TBBPA has long-range transport potential

  2. Hydrazine reagents as derivatizing agents in environmental analysis--a critical review.

    Science.gov (United States)

    Vogel, M; Büldt, A; Karst, U

    2000-04-01

    Hydrazine reagents are a well-known group of derivatizing agents for the determination of aldehydes and ketones in liquid and gaseous samples. Within this article, the most important hydrazine reagents are critically summarized, and their major applications in different fields, including environmental analysis, food chemistry and industrial analysis are introduced. As 2,4-dinitrophenylhydrazine (DNPH) is the basic reagent for several international standard procedures, its properties are discussed in detail. Particular focus is directed on the chemistry of the hydrazine reagents, and chemical interferences are considered. Recent methods for the determination of various oxidants using hydrazine reagents are presented as well. Due to limited space, this review does not cover the related field of carbohydrate analysis, although many chemical aspects are similar.

  3. Calibration samples for accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Hershberger, R.L.; Flynn, D.S.; Gabbard, F.

    1981-01-01

    Radioactive samples with precisely known numbers of atoms are useful as calibration sources for lifetime measurements using accelerator mass spectrometry. Such samples can be obtained in two ways: either by measuring the production rate as the sample is created or by measuring the decay rate after the sample has been obtained. The latter method requires that a large sample be produced and that the decay constant be accurately known. The former method is a useful and independent alternative, especially when the decay constant is not well known. The facilities at the University of Kentucky for precision measurements of total neutron production cross sections offer a source of such calibration samples. The possibilities, while quite extensive, would be limited to the proton rich side of the line of stability because of the use of (p,n) and (α,n) reactions for sample production

  4. Combination of pentafluorophenylhydrazine derivatization and isotope dilution LC-MS/MS techniques for the quantification of apurinic/apyrimidinic sites in cellular DNA.

    Science.gov (United States)

    Li, Jie; Leung, Elvis M K; Choi, Martin M F; Chan, Wan

    2013-05-01

    Apurinic/apyrimidinic (AP) sites are common DNA lesions arising from spontaneous hydrolysis of the N-glycosidic bond and base-excision repair mechanisms of the modified bases. Due to the strong association of AP site formation with physically/chemically induced DNA damage, quantifying AP sites provides important information for risk assessment of exposure to genotoxins and oxidative stress. However, rigorous quantification of AP sites in DNA has been hampered by technical problems relating to the sensitivity and selectivity of existing analytical methods. We have developed a new isotope dilution liquid chromatography-coupled tandem mass spectrometry (LC-MS/MS) method for the rigorous quantification of AP sites in genomic DNA. The method entails enzymatic digestion of AP site-containing DNA by endo- and exonucleases, derivatization with pentafluorophenylhydrazine (PFPH), addition of an isotopically labeled PFPH derivative as internal standard, and quantification by LC-MS/MS. The combination of PFPH derivatization with LC-MS/MS analysis on a triple quadrupole mass spectrometer allows for sensitive and selective quantification of AP sites in DNA at a detection limit of 6.5 fmol, corresponding to 4 AP sites/10(9) nt in 5 μg of DNA, which is at least ten times more sensitive than existing analytical methods. The protocol was validated by AP site-containing oligonucleotides and applied in quantifying methyl methanesulfonate-induced formation of AP sites in cellular DNA.

  5. Separation of amino acids and antibiotics by narrow-bore and normal-bore high-performance liquid chromatography with pre-column derivatization.

    Science.gov (United States)

    Fiedler, H P; Plaga, A

    1987-01-16

    The selectivity, efficiency and lifetime of normal- and narrow-bore columns for high-performance liquid chromatography were investigated for the separation and quantification of amino acids and the amino acid-like antibiotics phosphinothricin and phosphinothricylalanylalanine in biological samples. These compounds were determined by an automated pre-column derivatization with o-phthalaldehyde-2-mercaptoethanol reagent and UV detection at 338 nm.

  6. Quantification of steroid conjugates using fast atom bombardment mass spectrometry

    International Nuclear Information System (INIS)

    Gaskell, S.J.

    1990-01-01

    Fast atom bombardment/mass spectrometry or liquid secondary ion mass spectrometry provides the capability for direct analysis of steroid conjugates (sulfates, glucuronides) without prior hydrolysis or derivatization. During the analysis of biologic extracts, limitations on the sensitivity of detection arise from the presence of co-extracted material which may suppress or obscure the analyte signal. A procedure is described for the quantitative determination of dehydroepiandrosterone sulfate in serum which achieved selective isolation of the analyte using immunoadsorption extraction and highly specific detection using tandem mass spectrometry. A stable isotope-labeled analog [( 2H2]dehydroepiandrosterone sulfate) was used as internal standard. Fast atom bombardment of dehydroepiandrosterone sulfate yielded abundant [M-H]- ions that fragmented following collisional activation to give HSO4-; m/z 97. During fast atom bombardment/tandem mass spectrometry of serum extracts, a scan of precursor ions fragmenting to give m/z 97 detected dehydroepiandrosterone sulfate and the [2H2]-labeled analog with a selectivity markedly superior to that observed using conventional mass spectrometry detection. Satisfactory agreement was observed between quantitative data obtained in this way and data obtained by gas chromatography/mass spectrometry of the heptafluorobutyrates of dehydroepiandrosterone sulfate and [2H2]dehydroepiandrosterone sulfate obtained by direct derivatization. 21 refs

  7. Nonreductive chemical release of intact N-glycans for subsequent labeling and analysis by mass spectrometry.

    Science.gov (United States)

    Yuan, Jiangbei; Wang, Chengjian; Sun, Yujiao; Huang, Linjuan; Wang, Zhongfu

    2014-10-01

    A novel strategy is proposed, using cost-saving chemical reactions to generate intact free reducing N-glycans and their fluorescent derivatives from glycoproteins for subsequent analysis. N-Glycans without core α-1,3-linked fucose are released in reducing form by selective hydrolysis of the N-type carbohydrate-peptide bond of glycoproteins under a set of optimized mild alkaline conditions and are comparable to those released by commonly used peptide-N-glycosidase (PNGase) F in terms of yield without any detectable side reaction (peeling or deacetylation). The obtained reducing glycans can be routinely derivatized with 2-aminobenzoic acid (2-AA), 1-phenyl-3-methyl-5-pyrazolone (PMP), and potentially some other fluorescent reagents for comprehensive analysis. Alternatively, the core α-1,3-fucosylated N-glycans are released in mild alkaline medium and derivatized with PMP in situ, and their yields are comparable to those obtained using commonly used PNGase A without conspicuous peeling reaction or any detectable deacetylation. Using this new technique, the N-glycans of a series of purified glycoproteins and complex biological samples were successfully released and analyzed by electrospray ionization mass spectrometry (ESI-MS) and tandem mass spectrometry (MS/MS), demonstrating its general applicability to glycomic studies. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Post-column derivatization capillary electrochromatography for detection of biogenic amines in tuna-meat.

    Science.gov (United States)

    Oguri, Shigeyuki; Okuya, Yukie; Yanase, Yukiko; Suzuki, Sayaka

    2008-08-15

    A system to perform post-column derivatization capillary electrochromatography (CEC) was developed for the first time. The system mainly included a 4-microm (O.D.) silica packed column (200 mm effective length x 0.1 mm inner diameter I.D.) with micro-magnetic particles (MMPs) frits, a T-junction connector, an in-line fluorescence detector and a high-voltage power supply. The system was evaluated by using histamine (HA) as a standard biogenic amine for this study. A 5 microM HA solution was loaded at the anodic site of the capillary column by applying 3 kV for 5s. Then, HA was electrophoretically eluted with a 20mM phosphate buffer (pH 7) by applying 3 kV, and was derivatized with 3mM o-phthalaldehyde (OPA)/N-acetylcysteine (NAC) in 100 mM borate (pH 10), which was continuously delivered through the reagent-loading capillary tube by gravity into the T-junction connector. HA derivative was finally detected with the in-line fluorescence detector (lambda(Ex)=340 nm, lambda(Em)=450 nm) at 9.7 min after sample loading. To test the utility of this system, it was next employed for its ability to detect the presence of HA and other kinds of biogenic amines, including cadaverine (Cad), spermidine (Spm) and tyramine (Tyr) in tuna-meat, once the validity of the method had been confirmed.

  9. The use of mass spectrometry in peptide chemistry

    NARCIS (Netherlands)

    Leclercq, P.A.; White, P.A.; Hägele, K.; Desiderio, D.M.; Meienhofer, J.

    1972-01-01

    A review with 16 refs. Methods are detailed for derivatizing peptides (mg quantities) in order to provide sufficient volatility for mass spectrometry (at least 10-5 mm vapor pressure at 300 Deg is required). Three steps are used in producing the desired derivs.: (a) arginine side chains are

  10. Sampling and analyte enrichment strategies for ambient mass spectrometry.

    Science.gov (United States)

    Li, Xianjiang; Ma, Wen; Li, Hongmei; Ai, Wanpeng; Bai, Yu; Liu, Huwei

    2018-01-01

    Ambient mass spectrometry provides great convenience for fast screening, and has showed promising potential in analytical chemistry. However, its relatively low sensitivity seriously restricts its practical utility in trace compound analysis. In this review, we summarize the sampling and analyte enrichment strategies coupled with nine modes of representative ambient mass spectrometry (desorption electrospray ionization, paper vhspray ionization, wooden-tip spray ionization, probe electrospray ionization, coated blade spray ionization, direct analysis in real time, desorption corona beam ionization, dielectric barrier discharge ionization, and atmospheric-pressure solids analysis probe) that have dramatically increased the detection sensitivity. We believe that these advances will promote routine use of ambient mass spectrometry. Graphical abstract Scheme of sampling stretagies for ambient mass spectrometry.

  11. Quantitative profiling of O-glycans by electrospray ionization- and matrix-assisted laser desorption ionization-time-of-flight-mass spectrometry after in-gel derivatization with isotope-coded 1-phenyl-3-methyl-5-pyrazolone

    International Nuclear Information System (INIS)

    Sić, Siniša; Maier, Norbert M.; Rizzi, Andreas M.

    2016-01-01

    The potential and benefits of isotope-coded labeling in the context of MS-based glycan profiling are evaluated focusing on the analysis of O-glycans. For this purpose, a derivatization strategy using d_0/d_5-1-phenyl-3-methyl-5-pyrazolone (PMP) is employed, allowing O-glycan release and derivatization to be achieved in one single step. The paper demonstrates that this release and derivatization reaction can be carried out also in-gel with only marginal loss in sensitivity compared to in-solution derivatization. Such an effective in-gel reaction allows one to extend this release/labeling method also to glycoprotein/glycoform samples pre-separated by gel-electrophoresis without the need of extracting the proteins/digested peptides from the gel. With highly O-glycosylated proteins (e.g. mucins) LODs in the range of 0.4 μg glycoprotein (100 fmol) loaded onto the electrophoresis gel can be attained, with minor glycosylated proteins (like IgAs, FVII, FIX) the LODs were in the range of 80–100 μg (250 pmol–1.5 nmol) glycoprotein loaded onto the gel. As second aspect, the potential of isotope coded labeling as internal standardization strategy for the reliable determination of quantitative glycan profiles via MALDI-MS is investigated. Towards this goal, a number of established and emerging MALDI matrices were tested for PMP-glycan quantitation, and their performance is compared with that of ESI-based measurements. The crystalline matrix 2,6-dihydroxyacetophenone (DHAP) and the ionic liquid matrix N,N-diisopropyl-ethyl-ammonium 2,4,6-trihydroxyacetophenone (DIEA-THAP) showed potential for MALDI-based quantitation of PMP-labeled O-glycans. We also provide a comprehensive overview on the performance of MS-based glycan quantitation approaches by comparing sensitivity, LOD, accuracy and repeatability data obtained with RP-HPLC-ESI-MS, stand-alone nano-ESI-MS with a spray-nozzle chip, and MALDI-MS. Finally, the suitability of the isotope-coded PMP labeling strategy for

  12. Quantitative profiling of O-glycans by electrospray ionization- and matrix-assisted laser desorption ionization-time-of-flight-mass spectrometry after in-gel derivatization with isotope-coded 1-phenyl-3-methyl-5-pyrazolone

    Energy Technology Data Exchange (ETDEWEB)

    Sić, Siniša; Maier, Norbert M.; Rizzi, Andreas M., E-mail: Andreas.Rizzi@univie.ac.at

    2016-09-07

    The potential and benefits of isotope-coded labeling in the context of MS-based glycan profiling are evaluated focusing on the analysis of O-glycans. For this purpose, a derivatization strategy using d{sub 0}/d{sub 5}-1-phenyl-3-methyl-5-pyrazolone (PMP) is employed, allowing O-glycan release and derivatization to be achieved in one single step. The paper demonstrates that this release and derivatization reaction can be carried out also in-gel with only marginal loss in sensitivity compared to in-solution derivatization. Such an effective in-gel reaction allows one to extend this release/labeling method also to glycoprotein/glycoform samples pre-separated by gel-electrophoresis without the need of extracting the proteins/digested peptides from the gel. With highly O-glycosylated proteins (e.g. mucins) LODs in the range of 0.4 μg glycoprotein (100 fmol) loaded onto the electrophoresis gel can be attained, with minor glycosylated proteins (like IgAs, FVII, FIX) the LODs were in the range of 80–100 μg (250 pmol–1.5 nmol) glycoprotein loaded onto the gel. As second aspect, the potential of isotope coded labeling as internal standardization strategy for the reliable determination of quantitative glycan profiles via MALDI-MS is investigated. Towards this goal, a number of established and emerging MALDI matrices were tested for PMP-glycan quantitation, and their performance is compared with that of ESI-based measurements. The crystalline matrix 2,6-dihydroxyacetophenone (DHAP) and the ionic liquid matrix N,N-diisopropyl-ethyl-ammonium 2,4,6-trihydroxyacetophenone (DIEA-THAP) showed potential for MALDI-based quantitation of PMP-labeled O-glycans. We also provide a comprehensive overview on the performance of MS-based glycan quantitation approaches by comparing sensitivity, LOD, accuracy and repeatability data obtained with RP-HPLC-ESI-MS, stand-alone nano-ESI-MS with a spray-nozzle chip, and MALDI-MS. Finally, the suitability of the isotope-coded PMP labeling

  13. Determination of hydrazine in drinking water: Development and multivariate optimization of a rapid and simple solid phase microextraction-gas chromatography-triple quadrupole mass spectrometry protocol.

    Science.gov (United States)

    Gionfriddo, Emanuela; Naccarato, Attilio; Sindona, Giovanni; Tagarelli, Antonio

    2014-07-04

    In this work, the capabilities of solid phase microextraction were exploited in a fully optimized SPME-GC-QqQ-MS analytical approach for hydrazine assay. A rapid and easy method was obtained by a simple derivatization reaction with propyl chloroformate and pyridine carried out directly in water samples, followed by automated SPME analysis in the same vial without further sample handling. The affinity of the different derivatized compounds obtained towards five commercially available SPME coatings was evaluated, in order to achieve the best extraction efficiency. GC analyses were carried out using a GC-QqQ-MS instrument in selected reaction monitoring (SRM) acquisition mode which has allowed the achievement of high specificity by selecting appropriate precursor-product ion couples improving the capability in analyte identification. The multivariate approach of experimental design was crucial in order to optimize derivatization reaction, SPME process and tandem mass spectrometry parameters. Accuracy of the proposed protocol, tested at 60, 200 and 800 ng L(-1), provided satisfactory values (114.2%, 83.6% and 98.6%, respectively), whereas precision (RSD%) at the same concentration levels were of 10.9%, 7.9% and 7.7% respectively. Limit of detection and quantification of 4.4 and 8.3 ng L(-1) were obtained. The reliable application of the proposed protocol to real drinking water samples confirmed its capability to be used as analytical tool for routine analyses. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. HPLC-CUPRAC post-column derivatization method for the determination of antioxidants: a performance comparison between porous silica and core-shell column packing.

    Science.gov (United States)

    Haque, Syed A; Cañete, Socrates Jose P

    2018-01-01

    An HPLC method employing a post-column derivatization strategy using the cupric reducing antioxidant capacity reagent (CUPRAC reagent) for the determining antioxidants in plant-based materials leverages the separation capability of regular HPLC approaches while allowing for detection specificity for antioxidants. Three different column types, namely core-shell and porous silica including two chemically different core-shell materials (namely phenyl-hexyl and C18), were evaluated to assess potential improvements that could be attained by changing from a porous silica matrix to a core-shell matrix. Tea extracts were used as sample matrices for the evaluation specifically looking at catechin and epigallocatechin gallate (EGCG). Both the C18 and phenyl-hexyl core-shell columns showed better performance compared to the C18 porous silica one in terms of separation, peak shape, and retention time. Among the two core-shell materials, the phenyl-hexyl column showed better resolving power compared to the C18 column. The CUPRAC post-column derivatization method can be improved using core-shell columns and suitable for quantifying antioxidants, exemplified by catechin and EGCG, in tea samples.

  15. Applications of Isotope Ratio Mass Spectrometry in Sports Drug Testing Accounting for Isotope Fractionation in Analysis of Biological Samples.

    Science.gov (United States)

    Piper, Thomas; Thevis, Mario

    2017-01-01

    The misuse of anabolic-androgenic steroids (AAS) in sports aiming at enhancing athletic performance has been a challenging matter for doping control laboratories for decades. While the presence of a xenobiotic AAS or its metabolite(s) in human urine immediately represents an antidoping rule violation, the detection of the misuse of endogenous steroids such as testosterone necessitates comparably complex procedures. Concentration thresholds and diagnostic analyte ratios computed from urinary steroid concentrations of, e.g., testosterone and epitestosterone have aided identifying suspicious doping control samples in the past. These ratios can however also be affected by confounding factors and are therefore not sufficient to prove illicit steroid administrations. Here, carbon and, in rare cases, hydrogen isotope ratio mass spectrometry (IRMS) has become an indispensable tool. Importantly, the isotopic signatures of pharmaceutical steroid preparations commonly differ slightly but significantly from those found with endogenously produced steroids. By comparing the isotope ratios of endogenous reference compounds like pregnanediol to that of testosterone and its metabolites, the unambiguous identification of the urinary steroids' origin is accomplished. Due to the complex urinary matrix, several steps in sample preparation are inevitable as pure analyte peaks are a prerequisite for valid IRMS determinations. The sample cleanup encompasses steps such as solid phase or liquid-liquid extraction that are presumably not accompanied by isotopic fractionation processes, as well as more critical steps like enzymatic hydrolysis, high-performance liquid chromatography fractionation, and derivatization of analytes. In order to exclude any bias of the analytical results, each step of the analytical procedure is optimized and validated to exclude, or at least result in constant, isotopic fractionation. These efforts are explained in detail. © 2017 Elsevier Inc. All rights reserved.

  16. Derivatization and diffusive motion of molecular fullerenes: Ab initio and atomistic simulations

    Energy Technology Data Exchange (ETDEWEB)

    Berdiyorov, G., E-mail: gberdiyorov@qf.org.qa; Tabet, N. [Qatar Environment and Energy Research Institute (QEERI), Hamad Ben Khalifa University (HBKU), Qatar Foundation, P.O. Box 5825, Doha (Qatar); Harrabi, K. [Department of Physics, King Fahd University of Petroleum and Minerals, 31261 Dhahran (Saudi Arabia); Mehmood, U.; Hussein, I. A. [Department of Chemical Engineering, King Fahd University of Petroleum and Minerals, 31261 Dharan (Saudi Arabia); Peeters, F. M. [Departement Fysica, Universiteit Antwerpen, Groenenborgerlaan 171, B-2020 Antwerpen (Belgium); Zhang, J. [Department of Materials and London Centre for Nanotechnology, Imperial College London, SW7 2AZ London (United Kingdom); McLachlan, M. A. [Department of Materials and Centre for Plastic Electronics, Imperial College London, SW7 2AZ London (United Kingdom)

    2015-07-14

    Using first principles density functional theory in combination with the nonequilibrium Green's function formalism, we study the effect of derivatization on the electronic and transport properties of C{sub 60} fullerene. As a typical example, we consider [6,6]-phenyl-C{sub 61}-butyric acid methyl ester (PCBM), which forms one of the most efficient organic photovoltaic materials in combination with electron donating polymers. Extra peaks are observed in the density of states (DOS) due to the formation of new electronic states localized at/near the attached molecule. Despite such peculiar behavior in the DOS of an isolated molecule, derivatization does not have a pronounced effect on the electronic transport properties of the fullerene molecular junctions. Both C{sub 60} and PCBM show the same response to finite voltage biasing with new features in the transmission spectrum due to voltage induced delocalization of some electronic states. We also study the diffusive motion of molecular fullerenes in ethanol solvent and inside poly(3-hexylthiophene) lamella using reactive molecular dynamics simulations. We found that the mobility of the fullerene reduces considerably due to derivatization; the diffusion coefficient of C{sub 60} is an order of magnitude larger than the one for PCBM.

  17. In-source formation of N-acetyl-p-benzoquinone imine (NAPQI), the putatively toxic acetaminophen (paracetamol) metabolite, after derivatization with pentafluorobenzyl bromide and GC-ECNICI-MS analysis.

    Science.gov (United States)

    Tsikas, Dimitrios; Trettin, Arne; Zörner, Alexander A; Gutzki, Frank-Mathias

    2011-05-15

    Pentafluorobenzyl (PFB) bromide (PFB-Br) is a versatile derivatization reagent for numerous classes of compounds. Under electron-capture negative-ion chemical ionization (ECNICI) conditions PFB derivatives of acidic compounds readily and abundantly ionize to produce intense anions due to [M-PFB](-). In the present article we investigated the PFB-Br derivatization of unlabelled acetaminophen (N-acetyl-p-aminophenol, NAPAP-d(0); paracetamol; MW 151) and tetradeuterated acetaminophen (NAPAP-d(4); MW 155) in anhydrous acetonitrile and their GC-ECNICI-MS behavior using methane as the buffer gas. In addition to the expected anions [M-PFB](-) at m/z 150 from NAPAP-d(0) and m/z 154 from NAPAP-d(4), we observed highly reproducibly almost equally intense anions at m/z 149 and m/z 153, respectively. Selected ion monitoring of these ions is suitable for specific and sensitive quantification of acetaminophen in human plasma and urine. Detailed investigations suggest in-source formation of N-acetyl-p-benzoquinone imine (NAPQI; MW 149), the putatively toxic acetaminophen metabolite, from the PFB ether derivative of NAPAP. GC-ECNICI-MS of non-derivatized NAPAP did not produce NAPQI. The peak area ratio of m/z 149 to m/z 150 and of m/z 153 to m/z 154 decreased with increasing ion-source temperature in the range 100-250°C. Most likely, NAPQI formed in the ion-source captures secondary electrons to become negatively charged (i.e., [NAPQI](-)) and thus detectable. Formation of NAPQI was not observed under electron ionization (EI) conditions, i.e., by GC-EI-MS, from derivatized and non-derivatized NAPAP. NAPQI was not detectable in flow injection analysis LC-MS of native NAPAP in positive electrospray ionization (ESI) mode, whereas in negative ESI mode low extent NAPQI formation was observed (<5%). Our results suggest that oxidation of drug derivatives in the ion-sources of mass spectrometers may form intermediates that are produced from activated drugs in enzyme-catalyzed reactions

  18. Analytical procedure for the in-vial derivatization-extraction of phenolic acids and flavonoids in methanolic and aqueous plant extracts followed by gas chromatography with mass selective detection.

    NARCIS (Netherlands)

    Fiamegos, Y.C.; Nanos, C.G.; Vervoort, J.J.M.; Stalikas, C.D.

    2004-01-01

    An in-vial simple method for the combined derivatization and extraction of phenolic acids and flavonoids from plant extracts and their direct determination with GC-MS, is described. The method is taking advantage of the beneficial potentials of phase transfer catalysis (PTC). Catalysts in soluble

  19. Detection of Stimulants and Narcotics by Liquid Chromatography-Tandem Mass Spectrometry and Gas Chromatography-Mass Spectrometry for Sports Doping Control.

    Science.gov (United States)

    Ahrens, Brian D; Kucherova, Yulia; Butch, Anthony W

    2016-01-01

    Sports drug testing laboratories are required to detect several classes of compounds that are prohibited at all times, which include anabolic agents, peptide hormones, growth factors, beta-2 agonists, hormones and metabolic modulators, and diuretics/masking agents. Other classes of compounds such as stimulants, narcotics, cannabinoids, and glucocorticoids are also prohibited, but only when an athlete is in competition. A single class of compounds can contain a large number of prohibited substances and all of the compounds should be detected by the testing procedure. Since there are almost 70 stimulants on the prohibited list it can be a challenge to develop a single screening method that will optimally detect all the compounds. We describe a combined liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) testing method for detection of all the stimulants and narcotics on the World Anti-Doping Agency prohibited list. Urine for LC-MS/MS testing does not require sample pretreatment and is a direct dilute and shoot method. Urine samples for the GC-MS method require a liquid-liquid extraction followed by derivatization with trifluoroacetic anhydride.

  20. Investigation of thiol derivatized gold nanoparticle sensors for gas analysis

    Science.gov (United States)

    Stephens, Jared S.

    Analysis of volatile organic compounds (VOCs) in air and exhaled breath by sensor array is a very useful testing technique. It can provide non-invasive, fast, inexpensive testing for many diseases. Breath analysis has been very successful in identifying cancer and other diseases by using a chemiresistor sensor or array with gold nanoparticles to detect biomarkers. Acetone is a biomarker for diabetes and having a portable testing device could help to monitor diabetic and therapeutic progress. An advantage to this testing method is it is conducted at room temperature instead of 200 degrees Celsius. 3. The objective of this research is to determine the effect of thiol derivatized gold nanoparticles based on sensor(s) detection of VOCs. The VOCs to be tested are acetone, ethanol, and a mixture of acetone and ethanol. Each chip is tested under all three VOCs and three concentration levels (0.1, 1, and 5.0 ppm). VOC samples are used to test the sensors' ability to detect and differentiate VOCs. Sensors (also referred to as a chip) are prepared using several types of thiol derivatized gold nanoparticles. The factors are: thiol compound and molar volume loading of the thiol in synthesis. The average resistance results are used to determine the VOC selectivity of the sensors tested. The results show a trend of increasing resistance as VOC concentration is increased relative to dry air; which is used as baseline for VOCs. Several sensors show a high selectivity to one or more VOCs. Overall the 57 micromoles of 4-methoxy-toluenethiol sensor shows the strongest selectivity for VOCs tested. 3. Gerfen, Kurt. 2012. Detection of Acetone in Air Using Silver Ion Exchanged ZSM-5 and Zinc Oxide Sensing Films. Master of Science thesis, University of Louisville.

  1. Liquid chromatography coupled to quadrupole-time of flight tandem mass spectrometry based quantitative structure-retention relationships of amino acid analogues derivatized via n-propyl chloroformate mediated reaction.

    Science.gov (United States)

    Kritikos, Nikolaos; Tsantili-Kakoulidou, Anna; Loukas, Yannis L; Dotsikas, Yannis

    2015-07-17

    In the current study, quantitative structure-retention relationships (QSRR) were constructed based on data obtained by a LC-(ESI)-QTOF-MS/MS method for the determination of amino acid analogues, following their derivatization via chloroformate esters. Molecules were derivatized via n-propyl chloroformate/n-propanol mediated reaction. Derivatives were acquired through a liquid-liquid extraction procedure. Chromatographic separation is based on gradient elution using methanol/water mixtures from a 70/30% composition to an 85/15% final one, maintaining a constant rate of change. The group of examined molecules was diverse, including mainly α-amino acids, yet also β- and γ-amino acids, γ-amino acid analogues, decarboxylated and phosphorylated analogues and dipeptides. Projection to latent structures (PLS) method was selected for the formation of QSRRs, resulting in a total of three PLS models with high cross-validated coefficients of determination Q(2)Y. For this reason, molecular structures were previously described through the use of descriptors. Through stratified random sampling procedures, 57 compounds were split to a training set and a test set. Model creation was based on multiple criteria including principal component significance and eigenvalue, variable importance, form of residuals, etc. Validation was based on statistical metrics Rpred(2),QextF2(2),QextF3(2) for the test set and Roy's metrics rm(Av)(2) and rm(δ)(2), assessing both predictive stability and internal validity. Based on aforementioned models, simplified equivalent were then created using a multi-linear regression (MLR) method. MLR models were also validated with the same metrics. The suggested models are considered useful for the estimation of retention times of amino acid analogues for a series of applications. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. 15N sample preparation for mass spectroscopy analysis

    International Nuclear Information System (INIS)

    Trivelin, P.C.O.; Salati, E.; Matsui, E.

    1973-01-01

    Technics for preparing 15 N samples to be analised is presented. Dumas method and oxidation by sodium hypobromite method are described in order to get the appropriate sample. Method to calculate 15 N ratio from mass spectrometry dates is also discussed [pt

  3. Solid-phase extraction and on-disc derivatization of the major benzodiazepines in urine using enzyme hydrolysis and Toxi-Lab VC MP3 column.

    Science.gov (United States)

    King, J W; King, L J

    1996-01-01

    Because of the increase in use of the newer benzodiazepines, we explored the opportunity to develop a gas chromatographic-mass spectrometric (GC-MS) method that encompasses most of the widely prescribed benzodiazepines in use today. The benzodiazepines included in our study are nordiazepam, oxazepam, temazepam, lorazepam, alpha-hydroxyalprazolam, alpha-hydroxytriazolam, desalkylflurazepam, and 2-hydroxyethylflurazepam. Using 1.0 mL of urine as the matrix, we added the enzyme Glusulase and incubated the specimens for 2 h to obtain the free drugs. The hydrolyzed samples were then loaded onto a Toxi-Lab Spec VC MP3 column containing a 15-mg disc. On-disc derivatization was accomplished by adding N-methyl-N-(t-butyldimethylsilyl) trifluroacetamide (MTBSTFA) with 1% TBDMSCI to the disc. The derivatives were then placed in a GC vial and analyzed by GC-MS in the selected ion monitoring mode. These results were then compared to confirmed positives by the traditional acid hydrolysis GC-MS method.

  4. Direct solid phase microextraction combined with gas chromatography - Mass spectrometry for the determination of biogenic amines in wine.

    Science.gov (United States)

    Papageorgiou, Myrsini; Lambropoulou, Dimitra; Morrison, Calum; Namieśnik, Jacek; Płotka-Wasylka, Justyna

    2018-06-01

    A direct method based on immersion solid phase microextraction (DI-SPME) gas chromatography mass-spectrometry (GC-MS) was optimized and validated for the determination of 16 biogenic amines in Polish wines. In the analysis two internal standards were used: 1,7-diaminoheptane and bis-3-aminopropylamine. The method allows for simultaneous extraction and derivatization, providing a simple and fast mode of extraction and enrichment. Different parameters which affect the extraction procedure were studied and optimized including ionic strength (0-25%), fiber materials (PDMS/DVB, PDMS/DVD + OC, Polyacrylate, Carboxen/PDMS and DVB/CAR/PDMS) and timings of the extraction, derivatization and desorption processes. Validation studies confirmed the linearity, sensitivity, precision and accuracy of the method. The method was successfully applied to the analysis of 44 wine samples originating from several regions of Poland and 3 wine samples from other countries. Analysis showed that many of the samples contained all examined biogenic amines. The method, assessed using an Eco-Scale tool with satisfactory results, was found to be green in terms of hazardous chemicals and solvents usage, energy consumption and production of waste. Therefore the proposed method can be safely used in the wine industry for routine analysis of BAs in wine samples with a minimal detrimental impact on human health and the environment. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Microfabricated Devices for Sample Extraction, Concentrations, and Related Sample Processing Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Gang; Lin, Yuehe

    2006-12-01

    This is an invited book chapter. As with other analytical techniques, sample pretreatments, sample extraction, sample introduction, and related techniques are of extreme importance for micro-electro-mechanical systems (MEMS). Bio-MEMS devices and systems start with a sampling step. The biological sample then usually undergoes some kinds of sample preparation steps before the actual analysis. These steps may involve extracting the target sample from its matrix, removing interferences from the sample, derivatizing the sample to detectable species, or performing a sample preconcentration step. The integration of the components for sample pretreatment into microfluidic devices represents one of the remaining the bottle-neck towards achieving true miniaturized total analysis systems (?TAS). This chapter provides a thorough state-of-art of the developments in this field to date.

  6. Simultaneous quantification of the major bile acids in artificial Calculus bovis by high-performance liquid chromatography with precolumn derivatization and its application in quality control.

    Science.gov (United States)

    Shi, Yan; Xiong, Jing; Sun, Dongmei; Liu, Wei; Wei, Feng; Ma, Shuangcheng; Lin, Ruichao

    2015-08-01

    An accurate and sensitive high-performance liquid chromatography method coupled with ultralviolet detection and precolumn derivatization was developed for the simultaneous quantification of the major bile acids in Artificial Calculus bovis, including cholic acid, hyodeoxycholic acid, chenodeoxycholic acid, and deoxycholic acid. The extraction, derivatization, chromatographic separation, and detection parameters were fully optimized. The samples were extracted with methanol by ultrasonic extraction. Then, 2-bromine-4'-nitroacetophenone and 18-crown ether-6 were used for derivatization. The chromatographic separation was performed on an Agilent SB-C18 column (250 × 4.6 mm id, 5 μm) at a column temperature of 30°C and liquid flow rate of 1.0 mL/min using water and methanol as the mobile phase with a gradient elution. The detection wavelength was 263 nm. The method was extensively validated by evaluating the linearity (r(2) ≥ 0.9980), recovery (94.24-98.91%), limits of detection (0.25-0.31 ng) and limits of quantification (0.83-1.02 ng). Seventeen samples were analyzed using the developed and validated method. Then, the amounts of bile acids were analyzed by hierarchical agglomerative clustering analysis and principal component analysis. The results of the chemometric analysis showed that the contents of these compounds reflect the intrinsic quality of artificial Calculus bovis, and two compounds (hyodeoxycholic acid and chenodeoxycholic acid) were the most important markers for quality evaluating. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. High-sensitivity simultaneous liquid chromatography-tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma

    Institute of Scientific and Technical Information of China (English)

    Abhishek Gandhi; Swati Guttikar; Priti Trivedi

    2015-01-01

    A sensitive and simultaneous liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of ethinyl estradiol and levonorgestrel. The analytes were extracted with methyl-tert-butyl ether: n-hexane (50:50, v/v) solvent mixture, followed by dansyl derivatization. The chromatographic separation was performed on a Kinetex C18 (50 mm × 4.6 mm, 2.6μm) column with a mobile phase of 0.1% (v/v) formic acid in water and acetonitrile in gradient composition. The mass transitions were monitored in electrospray positive ionization mode. The assay exhibited a linear range of 0.100-20.0 ng/mL for levonorgestrel and 4.00-500 pg/mL for ethinyl estradiol in human plasma. A run time of 9.0 min for each sample made it possible to analyze a throughput of more than 100 samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic and bioequivalence studies.

  8. Determination of Phenolic Acids and Flavonoids in Taraxacum formosanum Kitam by Liquid Chromatography-Tandem Mass Spectrometry Coupled with a Post-Column Derivatization Technique

    Directory of Open Access Journals (Sweden)

    Hung-Ju Chen

    2011-12-01

    Full Text Available A liquid chromatography-tandem mass spectrometry method (LC-MS/MS was developed for the determination of phenolic acids and flavonoids in a medicinal Chinese herb Taraxacum formosanum Kitam. Initially, both phenolic acids and flavonoids were extracted with 50% ethanol in a water-bath at 60 °C for 3 h and eventually separated into acidic fraction and neutral fraction by using a C18 cartridge. A total of 29 compounds were separated within 68 min by employing a Gemini C18 column and a gradient solvent system of 0.1% formic acid and acetonitrile at a flow rate of 1.0 mL/min. Based on the retention behavior as well as absorption and mass spectra, 19 phenolic acids and 10 flavonoids were identified and quantified in T. formosanum, with the former ranging from 14.1 μg/g to 10,870.4 μg/g, and the latter from 9.9 μg/g to 325.8 μg/g. For further identification of flavonoids, a post-column derivatization method involving shift reagents such as sodium acetate or aluminum chloride was used and the absorption spectral characteristics without or with shift reagents were compared. An internal standard syringic acid was used for quantitation of phenolic acids, whereas (± naringenin was found suitable for quantitation of flavonoids. The developed LC-MS/MS method showed high reproducibility, as evident from the relative standard deviation (RSD values for intra-day and inter-day variability being 1.0–6.8% and 2.0–7.7% for phenolic acids and 3.7–7.4% and 1.5–8.1% for flavonoids, respectively, and thus may be applied for simultaneous determination of phenolic acids and flavonoids in Chinese herb and nutraceuticals.

  9. Quantitation of fumonisin B1 and B2 in feed using FMOC pre-column derivatization with HPLC and fluorescence detection.

    Science.gov (United States)

    Smith, Lori L; Francis, Kyle A; Johnson, Joseph T; Gaskill, Cynthia L

    2017-11-01

    Pre-column derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) was determined to be effective for quantitation of fumonisins B 1 and B 2 in feed. Liquid-solid extraction, clean-up using immunoaffinity solid phase extraction chromatography, and FMOC-derivatization preceded analysis by reverse phase HPLC with fluorescence. Instrument response was unchanged in the presence of matrix, indicating no need to use matrix-matched calibrants. Furthermore, high method recoveries indicated calibrants do not need to undergo clean-up to account for analyte loss. Established method features include linear instrument response from 0.04-2.5µg/mL and stable derivatized calibrants over 7days. Fortified cornmeal method recoveries from 0.1-30.0μg/g were determined for FB 1 (75.1%-109%) and FB 2 (96.0%-115.2%). Inter-assay precision ranged from 1.0%-16.7%. Method accuracy was further confirmed using certified reference material. Inter-laboratory comparison with naturally-contaminated field corn demonstrated equivalent results with conventional derivatization. These results indicate FMOC derivatization is a suitable alternative for fumonisins B 1 and B 2 quantitation in corn-based feeds. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Small Body GN and C Research Report: G-SAMPLE - An In-Flight Dynamical Method for Identifying Sample Mass [External Release Version

    Science.gov (United States)

    Carson, John M., III; Bayard, David S.

    2006-01-01

    G-SAMPLE is an in-flight dynamical method for use by sample collection missions to identify the presence and quantity of collected sample material. The G-SAMPLE method implements a maximum-likelihood estimator to identify the collected sample mass, based on onboard force sensor measurements, thruster firings, and a dynamics model of the spacecraft. With G-SAMPLE, sample mass identification becomes a computation rather than an extra hardware requirement; the added cost of cameras or other sensors for sample mass detection is avoided. Realistic simulation examples are provided for a spacecraft configuration with a sample collection device mounted on the end of an extended boom. In one representative example, a 1000 gram sample mass is estimated to within 110 grams (95% confidence) under realistic assumptions of thruster profile error, spacecraft parameter uncertainty, and sensor noise. For convenience to future mission design, an overall sample-mass estimation error budget is developed to approximate the effect of model uncertainty, sensor noise, data rate, and thrust profile error on the expected estimate of collected sample mass.

  11. Rapid Determination of the Monosaccharide Composition and Contents in Tea Polysaccharides from Yingshuang Green Tea by Pre-Column Derivatization HPLC

    Directory of Open Access Journals (Sweden)

    Yujie Ai

    2016-01-01

    Full Text Available A pre-column derivatization high-performance liquid chromatography (HPLC method was developed and optimized to characterize and quantify the monosaccharides present in tea polysaccharides (TPS isolated from Yingshuang green tea. TPS sample was hydrolyzed with trifluoroacetic acid, subjected to pre-column derivatization using 1-phenyl-3-methyl-5-pyrazolone (PMP, and separated on an Agilent TC-C18 column (4.6 mm × 250 mm, 5 μm with UV detection at 250 nm. A mixture of ten PMP derivatives of standard monosaccharides (mannose, ribose, rhamnose, glucuronic acid, galacturonic acid, glucose, xylose, galactose, arabinose, and fucose could be baseline separated within 20 min. Moreover, quantitative analysis of the component monosaccharides in Yingshuang green tea TPS was achieved, indicating the TPS consisted of mannose, ribose, rhamnose, glucuronic acid, galacturonic acid, glucose, xylose, galactose, and arabinose in the molar contents of 0.72, 0.78, 0.89, 0.13, 0.15, 0.36, 0.39, 0.36, 0.36, and 0.38 μM, respectively. Recovery efficiency for component monosaccharides from TPS ranged from 93.6 to 102.4% with RSD values lower than 2.5%. In conclusion, pre-column derivatization HPLC provides a rapid, reproducible, accurate, and quantitative method for analysis of the monosaccharide composition and contents in TPS, which may help to further explore the relationship between TPS monosaccharides isolated from different tea varieties and their biological activity.

  12. Protein Analysis by Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Cindic, M.

    2008-04-01

    Full Text Available Soft ionization techniques, electrospray (ESI and matrix-assisted laser desorption/ionization (MALDI make the analysis of biomolecules by mass spectrometry (MS possible. MS is used for determination of the molecular weight of peptides and protein, sequence analysis, characterization of protein-ligand interactions etc. The detection limit, resolution and mass accuracy depend on instrument used (Table 1. Impurities (buffers, salts, detergents can reduce the ion intensities or even totally suppress them, so a separation method (chromatography, 2D-gel electrophoresis must be used for purification of the sample.Molecular mass of intact protein can be determined by ESI or MALDI MS. Multiply charged ions are produced by ESI MS, while singly charged ions are predominant in MALDI spectra (Fig. 2.Sequence analysis of proteins by MS can be performed using peptide mass fingerprint. In this method, proteins are separated by 2-D gel electrophoresis and digested with specific protease (Table 2 or digested and then separated by two-dimensional chromatography (Fig. 1. The obtained peptide mixtures are analyzed by MS or MALDI-TOF technique. The masses determined by MS are compared with calculated masses from database entries. Different algorithms have been developed for protein identification. Example of posttranslational modifications (N- and O-glycosylation and protein sequence complex analysis after dual digestion (endoproteinase digestion followed by endoglycosidase digestion is shown in Fig. 3.It is known that detection of peptides by MS is influenced by intrinsic properties like amino acid composition, the basicity of the C-terminal amino acid, hydrophobicity, etc. Arginine-containing peptides dominate in MS spectra of tryptic digest, so the chemical derivatization of lysine terminal residue by O-methilisourea or 2-methoxy-4,5-1H-imidazole was suggested (Fig. 4.The peptide mass fingerprint method can be improved further by peptide fragmentation using tandem

  13. Hydrazine Determination in Sludge Samples by High Performance Liquid Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    G. Elias; G. A. Park

    2006-02-01

    A high-performance liquid chromatographic method using ultraviolet (UV) detection was developed to detect and quantify hydrazine in a variety of environmental matrices. The method was developed primarily for sludge samples, but it is also applicable to soil and water samples. The hydrazine in the matrices was derivatized to their hydrazones with benzaldehyde. The derivatized hydrazones were separated using high performance liquid chromatography (HPLC) with a reversed-phase C-18 column in an isocratic mode with methanol-water (95:5, v/v), and detected with UV detection at 313 nm. The detection limit (25 ml) for the new analytical method is 0.0067 mg ml-1of hydrazine. Hydrazine showed low recovery in soil samples because components in soil oxidized hydrazine. Sludge samples that contained relatively high soil content also showed lower recovery. The technique is relatively simple and cost-effective, and is applicable for hydrazine analysis in different environmental matrices.

  14. Determination of 2-alkylcyclobutanones by combining precolumn derivatization with 1-naphthalenyl hydrazine and ultra-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Meng, Xiangpeng; Tong, Tong; Wang, Lianrong; Liu, Hanxia; Chan, Wan

    2016-05-01

    2-Alkylcyclobutanones (2-ACBs) are uniquely formed when triglycerides-containing food products are exposed to ionizing radiation. Thus, 2-ACBs have been used as marker molecules to identify irradiated food. Most methods to determine 2-ACBs involve mass spectrometric detection after chromatographic separation. The spectrofluorometer is rarely used to determine 2-ACBs because these molecules do not fluoresce. In this study, we developed an ultra-performance liquid chromatography (UPLC) method to determine 2-ACBs. 2-ACBs were converted into fluorophores after reacting with 1-naphthalenyl hydrazine to facilitate their sensitive and selective detection using a fluorescence detector (FLD). Analysis of 2-ACBs using our developed UPLC-FLD method allows sensitive determination of 2-ACBs at a detection limit of 2 ng 2-ACBs per g of fat (30 pg/injection), which is significantly lower than that of existing analytical methods. After validation for trueness and precision, the method was applied to γ-irradiated chicken samples to determine their 2-ACB content. Comparative studies employing liquid chromatography-tandem mass spectrometric method revealed no systematic difference between the two methods, thereby demonstrating that the proposed UPLC-FLD method can be suitably used to determine 2-ACBs in irradiated foodstuffs. Graphical Abstract Determination of radiation-induced food-borne 2-dodecylcyclobutanone and 2-tetradecylcyclobutanone by combining 1-naphthalenyl hydrazine derivatization and ultra-performance liquid chromatography with fluorescence detection.

  15. Automated thermochemolysis reactor for detection of Bacillus anthracis endospores by gas chromatography–mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Li, Dan [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602 (United States); Rands, Anthony D.; Losee, Scott C. [Torion Technologies, American Fork, UT 84003 (United States); Holt, Brian C. [Department of Statistics, Brigham Young University, Provo, UT 84602 (United States); Williams, John R. [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602 (United States); Lammert, Stephen A. [Torion Technologies, American Fork, UT 84003 (United States); Robison, Richard A. [Department of Microbiology and Molecular Biology, Brigham Young University, Provo, UT 84602 (United States); Tolley, H. Dennis [Department of Statistics, Brigham Young University, Provo, UT 84602 (United States); Lee, Milton L., E-mail: milton_lee@byu.edu [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602 (United States)

    2013-05-02

    Graphical abstract: -- Highlights: •An automated sample preparation system for Bacillus anthracis endospores was developed. •A thermochemolysis method was applied to produce and derivatize biomarkers for Bacillus anthracis detection. •The autoreactor controlled the precise delivery of reagents, and TCM reaction times and temperatures. •Solid phase microextraction was used to extract biomarkers, and GC–MS was used for final identification. •This autoreactor was successfully applied to the identification of Bacillus anthracis endospores. -- Abstract: An automated sample preparation system was developed and tested for the rapid detection of Bacillus anthracis endospores by gas chromatography–mass spectrometry (GC–MS) for eventual use in the field. This reactor is capable of automatically processing suspected bio-threat agents to release and derivatize unique chemical biomarkers by thermochemolysis (TCM). The system automatically controls the movement of sample vials from one position to another, crimping of septum caps onto the vials, precise delivery of reagents, and TCM reaction times and temperatures. The specific operations of introduction of sample vials, solid phase microextraction (SPME) sampling, injection into the GC–MS system, and ejection of used vials from the system were performed manually in this study, although they can be integrated into the automated system. Manual SPME sampling is performed by following visual and audible signal prompts for inserting the fiber into and retracting it from the sampling port. A rotating carousel design allows for simultaneous sample collection, reaction, biomarker extraction and analysis of sequential samples. Dipicolinic acid methyl ester (DPAME), 3-methyl-2-butenoic acid methyl ester (a fragment of anthrose) and two methylated sugars were used to compare the performance of the autoreactor with manual TCM. Statistical algorithms were used to construct reliable bacterial endospore signatures, and 24

  16. Automated thermochemolysis reactor for detection of Bacillus anthracis endospores by gas chromatography–mass spectrometry

    International Nuclear Information System (INIS)

    Li, Dan; Rands, Anthony D.; Losee, Scott C.; Holt, Brian C.; Williams, John R.; Lammert, Stephen A.; Robison, Richard A.; Tolley, H. Dennis; Lee, Milton L.

    2013-01-01

    Graphical abstract: -- Highlights: •An automated sample preparation system for Bacillus anthracis endospores was developed. •A thermochemolysis method was applied to produce and derivatize biomarkers for Bacillus anthracis detection. •The autoreactor controlled the precise delivery of reagents, and TCM reaction times and temperatures. •Solid phase microextraction was used to extract biomarkers, and GC–MS was used for final identification. •This autoreactor was successfully applied to the identification of Bacillus anthracis endospores. -- Abstract: An automated sample preparation system was developed and tested for the rapid detection of Bacillus anthracis endospores by gas chromatography–mass spectrometry (GC–MS) for eventual use in the field. This reactor is capable of automatically processing suspected bio-threat agents to release and derivatize unique chemical biomarkers by thermochemolysis (TCM). The system automatically controls the movement of sample vials from one position to another, crimping of septum caps onto the vials, precise delivery of reagents, and TCM reaction times and temperatures. The specific operations of introduction of sample vials, solid phase microextraction (SPME) sampling, injection into the GC–MS system, and ejection of used vials from the system were performed manually in this study, although they can be integrated into the automated system. Manual SPME sampling is performed by following visual and audible signal prompts for inserting the fiber into and retracting it from the sampling port. A rotating carousel design allows for simultaneous sample collection, reaction, biomarker extraction and analysis of sequential samples. Dipicolinic acid methyl ester (DPAME), 3-methyl-2-butenoic acid methyl ester (a fragment of anthrose) and two methylated sugars were used to compare the performance of the autoreactor with manual TCM. Statistical algorithms were used to construct reliable bacterial endospore signatures, and 24

  17. Removal of methyl violet dye by adsorption onto N-benzyltriazole derivatized dextran

    DEFF Research Database (Denmark)

    Cho, Eunae; Tahir, Muhammad Nazir; Kim, Hwanhee

    2015-01-01

    In this work, N-benzyltriazole derivatized dextran was evaluated for its potential as a novel carbohydrate-based adsorbent for the removal of methyl violet dye from water. The modified dextran was synthesized by a click reaction of pentynyl dextran and benzyl azide, and the structure...... was characterized by nuclear magnetic resonance spectroscopy, elemental analysis, and scanning electron microscopy. Dextran was substituted with a triazole-linked benzyl group. For decolorization of the dye effluent, adsorption is a very effective treatment; here, the driving force is based on hydrogen bonding, pi...... stacking, and electrostatic interaction between the methyl violet dye and the N-benzyltriazole derivatized dextran. Batch experiments were carried out to investigate the required contact time and the effects of pH, initial dye concentrations, and temperature. The experimental data were analyzed...

  18. [Determination of organotin compounds in plastic products by GC/MS after ethyl derivatization with sodium tetraethylborate].

    Science.gov (United States)

    Ohno, Hiroyuki; Suzuki, Masako; Nakashima, Shigehito; Aoyama, Taiki; Mitani, Kazunori

    2002-08-01

    A simultaneous determination method for 9 organotin compounds in polyvinyl chloride (PVC) and silicone products used as kitchen utensils and food packages was developed using ethyl derivatization with sodium tetraethylborate (NaBEt4). Organotin compounds were extracted with acetone-hexane (3:7) from the samples after acidification and the extract was filtered and concentrated at under 40 degrees C. After centrifugal separation, these compounds were derivatized with 2% NaBEt4 solution and determined by GC/MS. This method was applicable for simple routine analysis. Recoveries of spiked compounds were 49.1-118.1% for 3 PVC products and 88.8-102.2% for a siliconized paper. Monooctyltin, dioctyltin and trioctyltin compounds were found in all PVC food containers at the levels of 123-1,380 micrograms/g, 1,770-13,200 micrograms/g and 6.6-139 micrograms/g, respectively. They also were found in 3 gloves, 5 spouts, 1 hose and 5 pipes. Some PVC products contained monomethyltin, dimethyltin, trimethyltin, monobutyltin and dibutyltin compounds at the levels of 97.3-433 micrograms/g, 96.5-5,120 micrograms/g, 8.5-24.9 micrograms/g, 1.2-852 micrograms/g and 1.2-29.4 micrograms/g, respectively.

  19. Development of a novel selective ESI-MS derivatization reagent - ssynthesis and optimization for the analysis of aldehydes in biological mixtures

    NARCIS (Netherlands)

    Eggink, M.; Wijtmans, M.; de Esch, I.J.P.; Lingeman, H.; Niessen, W.M.A.; Irth, H.

    2008-01-01

    In LC-MS, derivatization is primarily used to improve ionization characteristics, especially for analytes that are not (efficiently) ionized by ESI or APCI such as aldehydes, sugars, and steroids. Derivatization strategies are then directed at the incorporation of a group with a permanent charge. A

  20. Determination of Nerve Agent Metabolites by Ultraviolet Femtosecond Laser Ionization Mass Spectrometry.

    Science.gov (United States)

    Hamachi, Akifumi; Imasaka, Tomoko; Nakamura, Hiroshi; Li, Adan; Imasaka, Totaro

    2017-05-02

    Nerve agent metabolites, i.e., isopropyl methylphosphonic acid (IMPA) and pinacolyl methylphosphonic acid (PMPA), were derivatized by reacting them with 2,3,4,5,6-pentafluorobenzyl bromide (PFBBr) and were determined by mass spectrometry using an ultraviolet femtosecond laser emitting at 267 and 200 nm as the ionization source. The analytes of the derivatized compounds, i.e., IMPA-PFB and PMPA-PFB, contain a large side-chain, and molecular ions are very weak or absent in electron ionization mass spectrometry. The use of ultraviolet femtosecond laser ionization mass spectrometry, however, resulted in the formation of a molecular ion, even for compounds such as these that contain a highly bulky functional group. The signal intensity was larger at 200 nm due to resonance-enhanced two-photon ionization. In contrast, fragmentation was suppressed at 267 nm (nonresonant two-photon ionization) especially for PMPA-PFB, thus resulting in a lower background signal. This favorable result can be explained by the small excess energy in ionization at 267 nm and by the low-frequency vibrational mode of a bulky trimethylpropyl group in PMPA.

  1. Hydrazinonicotinic acid derivatization for selective ionization and improved glycan structure characterization by MALDI-MS.

    Science.gov (United States)

    Jiao, Jing; Yang, Lijun; Zhang, Ying; Lu, Haojie

    2015-08-21

    The analysis of glycan is important for understanding cell biology and disease processes because the glycans play a key role in many important biological behaviors, such as cell division, cellular localization, tumor immunology and inflammation. Nevertheless, it is still hard work to analyze glycans by MALDI-MS, which generally stems from the inherent low abundance and the low ionization efficiency of glycans. Moreover, the difficulty in generating informative fragmentations further hinders glycans structure characterization. In this work, hydrazinonicotinic acid (HYNIC) was used as a novel derivatized reagent for improved and selective detection of glycans. Through tagging the reducing terminus of glycans with the diazanyl group of HYNIC, significant enhancement of the ionization efficiency of glycans was achieved. After derivatization, the signal to noise ratio (S/N) of the maltoheptaose was improved by more than one order of magnitude in positive mode. HYNIC derivatization also allowed the sensitive detection of sialylated glycan in negative mode, with a 15 fold enhancement of S/N. Interestingly, it is noteworthy that the HYNIC reagent not only effectively labeled the reducing end of glycans in the presence of tryptic peptides, but also suppressed the ionization of peptides, enabling the direct detection of glycans from glycoprotein without separation. Therefore, analysis of glycans became easier due to the omission of a pre-separation step. Importantly, by using different acid reagents as the catalyst, derivatized product signals corresponding to [M + Na](+) or [M + H](+) were obtained respectively, which yield complementary fragmentation patterns for the structure elucidation of glycans. Finally, more than 40 N-glycans were successfully detected in 10 μL human serum using this method.

  2. Application of a 1,1,3,3-tetramethylguanidine (TMG)/MeOH-CO2 in situ derivatization procedure for the gas chromatographic characterization of the fatty acid profile in olive oil.

    Science.gov (United States)

    Saliu, F; Anzano, M; Franzetti, A

    2015-03-01

    1,1,3,3-Tetramethylguanidine (TMG), methanol and carbon dioxide were investigated as switchable polarity solvents (SPS) in the simultaneous derivatization and extraction of triacylglycerols for the gas chromatographic (GC) characterization of olive oil. Three commercial olive oils were used as test samples. Results of the developed method did not differ statistically from those provided by reference derivatization procedures. The transesterification reaction was carried out under a very mild condition, one step and in situ, and no particular matrix interferences were evidenced. The method represented the first example of the use of a switchable polarity mixture for the preparation of methyl ester derivatives of fatty acids (FAME).

  3. β-Isocyanoalanine as an IR probe: comparison of vibrational dynamics between isonitrile and nitrile-derivatized IR probes.

    Science.gov (United States)

    Maj, Michał; Ahn, Changwoo; Kossowska, Dorota; Park, Kwanghee; Kwak, Kyungwon; Han, Hogyu; Cho, Minhaeng

    2015-05-07

    An infrared (IR) probe based on isonitrile (NC)-derivatized alanine 1 was synthesized and the vibrational properties of its NC stretching mode were investigated using FTIR and femtosecond IR pump-probe spectroscopy. It is found that the NC stretching mode is very sensitive to the hydrogen-bonding ability of solvent molecules. Moreover, its transition dipole strength is larger than that of nitrile (CN) in nitrile-derivatized IR probe 2. The vibrational lifetime of the NC stretching mode is found to be 5.5 ± 0.2 ps in both D2O and DMF solvents, which is several times longer than that of the azido (N3) stretching mode in azido-derivatized IR probe 3. Altogether these properties suggest that the NC group can be a very promising sensing moiety of IR probes for studying the solvation structure and dynamics of biomolecules.

  4. Simultaneous determination of diastereoisomeric and enantiomeric impurities in SSS-octahydroindole-2-carboxylic acid by chiral high-performance liquid chromatography with pre-column derivatization.

    Science.gov (United States)

    Wang, Jin Zhao; Zeng, Su; Hu, Gong Yun; Wang, Dan Hua

    2009-04-10

    SSS-Octahydroindole-2-carboxylic acid (SSS-Oic) is a key intermediate used in the synthesis of some angiotensin-converting enzyme (ACE) inhibitors. The separation of diastereoisomers and enantiomers of Oic was performed using a pre-column derivatization chiral HPLC method. Phenyl isothiocyanate (PITC) was used as the derivatization reagent. Three PITC derivatives of Oic stereoisomers were separated on an Ultron ES-OVM chiral column (150 mm x 4.6 mm, 5 microm). Derivatization conditions such as reaction temperature, reaction time and derivatization reagent concentration were investigated. The chromatographic conditions for separation of the three PITC-Oic derivatives were optimized. The method was successfully applied in the diastereoisomeric and enantiomeric purity test of SSS-Oic.

  5. A novel approach for the quantitation of carbohydrates in mash, wort, and beer with RP-HPLC using 1-naphthylamine for precolumn derivatization.

    Science.gov (United States)

    Rakete, Stefan; Glomb, Marcus A

    2013-04-24

    A novel universal method for the determination of reducing mono-, di-, and oligosaccharides in complex matrices on RP-HPLC using 1-naphthylamine for precolumn derivatization with sodium cyanoborhydride was established to study changes in the carbohydrate profile during beer brewing. Fluorescence and mass spectrometric detection enabled very sensitive analyses of beer-relevant carbohydrates. Mass spectrometry additionally allowed the identification of the molecular weight and thereby the degree of polymerization of unknown carbohydrates. Thus, carbohydrates with up to 16 glucose units were detected. Comparison demonstrated that the novel method was superior to fluorophore-assisted carbohydrate electrophoresis (FACE). The results proved the HPLC method clearly to be more powerful in regard to sensitivity and resolution. Analogous to FACE, this method was designated fluorophore-assisted carbohydrate HPLC (FAC-HPLC).

  6. Interface for the rapid analysis of liquid samples by accelerator mass spectrometry

    Science.gov (United States)

    Turteltaub, Kenneth; Ognibene, Ted; Thomas, Avi; Daley, Paul F; Salazar Quintero, Gary A; Bench, Graham

    2014-02-04

    An interface for the analysis of liquid sample having carbon content by an accelerator mass spectrometer including a wire, defects on the wire, a system for moving the wire, a droplet maker for producing droplets of the liquid sample and placing the droplets of the liquid sample on the wire in the defects, a system that converts the carbon content of the droplets of the liquid sample to carbon dioxide gas in a helium stream, and a gas-accepting ion source connected to the accelerator mass spectrometer that receives the carbon dioxide gas of the sample in a helium stream and introduces the carbon dioxide gas of the sample into the accelerator mass spectrometer.

  7. Immobilization of small molecules and proteins by radio-derivatized polystyrene

    International Nuclear Information System (INIS)

    Varga, J.M.; Fritsch, P.

    1990-01-01

    When molded polystyrene (PS) products (e.g., microtiter plates) or latex particles are irradiated with high-energy (1-10 Mrads) gamma rays in the presence of nonpolymerizable small molecules such as aromatic amines, some of these molecules incorporate into PS, which leads to the formation of radio-derivatized PS (RDPS). Two classes of RDPS can be identified regarding their ability for immobilization of biologically important molecules: (1) reactive RDPS that are able to form covalent bonds with molecules such as proteins without the help of cross-linkers, and (2) functionalized RDPS that can be used for the immobilization of molecules with activators (e.g., carbodiimides) or cross-linkers. The method can be used for the production of low-noise supports for binding assays. Most of the RDPS can be produced without impairment of the optical quality of PS, making derivatized microtiter plates suitable for colorimetric assays. The principle can be applied for the preparation of affinity sorbents, e.g., for high-performance affinity chromatography and for the immobilization of enzymes using latex PS particles

  8. Phosphopeptide Enrichment by Covalent Chromatography after Derivatization of Protein Digests Immobilized on Reversed-Phase Supports

    Science.gov (United States)

    Nika, Heinz; Nieves, Edward; Hawke, David H.; Angeletti, Ruth Hogue

    2013-01-01

    A rugged sample-preparation method for comprehensive affinity enrichment of phosphopeptides from protein digests has been developed. The method uses a series of chemical reactions to incorporate efficiently and specifically a thiol-functionalized affinity tag into the analyte by barium hydroxide catalyzed β-elimination with Michael addition using 2-aminoethanethiol as nucleophile and subsequent thiolation of the resulting amino group with sulfosuccinimidyl-2-(biotinamido) ethyl-1,3-dithiopropionate. Gentle oxidation of cysteine residues, followed by acetylation of α- and ε-amino groups before these reactions, ensured selectivity of reversible capture of the modified phosphopeptides by covalent chromatography on activated thiol sepharose. The use of C18 reversed-phase supports as a miniaturized reaction bed facilitated optimization of the individual modification steps for throughput and completeness of derivatization. Reagents were exchanged directly on the supports, eliminating sample transfer between the reaction steps and thus, allowing the immobilized analyte to be carried through the multistep reaction scheme with minimal sample loss. The use of this sample-preparation method for phosphopeptide enrichment was demonstrated with low-level amounts of in-gel-digested protein. As applied to tryptic digests of α-S1- and β-casein, the method enabled the enrichment and detection of the phosphorylated peptides contained in the mixture, including the tetraphosphorylated species of β-casein, which has escaped chemical procedures reported previously. The isolates proved highly suitable for mapping the sites of phosphorylation by collisionally induced dissociation. β-Elimination, with consecutive Michael addition, expanded the use of the solid-phase-based enrichment strategy to phosphothreonyl peptides and to phosphoseryl/phosphothreonyl peptides derived from proline-directed kinase substrates and to their O-sulfono- and O-linked β-N-acetylglucosamine (O

  9. Quantification of physiological levels of vitamin D3 and 25-hydroxyvitamin D3 in porcine fat and liver in subgram sample sizes

    DEFF Research Database (Denmark)

    Burild, Anders; Frandsen, Henrik Lauritz; Poulsen, Morten

    2014-01-01

    Most methods for the quantification of physiological levels of vitamin D3 and 25‐hydroxyvitamin D3 are developed for food analysis where the sample size is not usually a critical parameter. In contrast, in life science studies sample sizes are often limited. A very sensitive liquid chromatography...... with tandem mass spectrometry method was developed to quantify vitamin D3 and 25‐hydroxyvitamin D3 simultaneously in porcine tissues. A sample of 0.2–1 g was saponified followed by liquid–liquid extraction and normal‐phase solid‐phase extraction. The analytes were derivatized with 4‐phenyl‐1,2,4‐triazoline‐3...

  10. Large-volume constant-concentration sampling technique coupling with surface-enhanced Raman spectroscopy for rapid on-site gas analysis.

    Science.gov (United States)

    Zhang, Zhuomin; Zhan, Yisen; Huang, Yichun; Li, Gongke

    2017-08-05

    In this work, a portable large-volume constant-concentration (LVCC) sampling technique coupling with surface-enhanced Raman spectroscopy (SERS) was developed for the rapid on-site gas analysis based on suitable derivatization methods. LVCC sampling technique mainly consisted of a specially designed sampling cell including the rigid sample container and flexible sampling bag, and an absorption-derivatization module with a portable pump and a gas flowmeter. LVCC sampling technique allowed large, alterable and well-controlled sampling volume, which kept the concentration of gas target in headspace phase constant during the entire sampling process and made the sampling result more representative. Moreover, absorption and derivatization of gas target during LVCC sampling process were efficiently merged in one step using bromine-thiourea and OPA-NH 4 + strategy for ethylene and SO 2 respectively, which made LVCC sampling technique conveniently adapted to consequent SERS analysis. Finally, a new LVCC sampling-SERS method was developed and successfully applied for rapid analysis of trace ethylene and SO 2 from fruits. It was satisfied that trace ethylene and SO 2 from real fruit samples could be actually and accurately quantified by this method. The minor concentration fluctuations of ethylene and SO 2 during the entire LVCC sampling process were proved to be gas targets from real samples by SERS. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. New procedure of selected biogenic amines determination in wine samples by HPLC

    Energy Technology Data Exchange (ETDEWEB)

    Piasta, Anna M.; Jastrzębska, Aneta, E-mail: aj@chem.uni.torun.pl; Krzemiński, Marek P.; Muzioł, Tadeusz M.; Szłyk, Edward

    2014-06-27

    Highlights: • We proposed new procedure for derivatization of biogenic amines. • The NMR and XRD analysis confirmed the purity and uniqueness of derivatives. • Concentration of biogenic amines in wine samples were analyzed by RP-HPLC. • Sample contamination and derivatization reactions interferences were minimized. - Abstract: A new procedure for determination of biogenic amines (BA): histamine, phenethylamine, tyramine and tryptamine, based on the derivatization reaction with 2-chloro-1,3-dinitro-5-(trifluoromethyl)-benzene (CNBF), is proposed. The amines derivatives with CNBF were isolated and characterized by X-ray crystallography and {sup 1}H, {sup 13}C, {sup 19}F NMR spectroscopy in solution. The novelty of the procedure is based on the pure and well-characterized products of the amines derivatization reaction. The method was applied for the simultaneous analysis of the above mentioned biogenic amines in wine samples by the reversed phase-high performance liquid chromatography. The procedure revealed correlation coefficients (R{sup 2}) between 0.9997 and 0.9999, and linear range: 0.10–9.00 mg L{sup −1} (histamine); 0.10–9.36 mg L{sup -1} (tyramine); 0.09–8.64 mg L{sup −1} (tryptamine) and 0.10–8.64 mg L{sup −1} (phenethylamine), whereas accuracy was 97%–102% (recovery test). Detection limit of biogenic amines in wine samples was 0.02–0.03 mg L{sup −1}, whereas quantification limit ranged 0.05–0.10 mg L{sup −1}. The variation coefficients for the analyzed amines ranged between 0.49% and 3.92%. Obtained BA derivatives enhanced separation the analytes on chromatograms due to the inhibition of hydrolysis reaction and the reduction of by-products formation.

  12. Extractive alkylation of 6-mercaptopurine and determination in plasma by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Floberg, S; Hartvig, P; Lindström, B; Lönner-Holm, G; Odlind, B

    1981-09-11

    An analytical procedure was developed for the determination of 6-mercaptopurine in plasma. Owing to the polar character and low plasma concentration of the compound, extraction and derivatization was carried out directly from the plasma sample by extractive alkylation. Determination was made using gas chromatography-mass spectrometry with multiple-ion detection. Conditions with respect to the rate of formation and the stability of the derivative formed in the extractive alkylation step were evaluated. The selectively of the method to azathioprine and to metabolites was thoroughly investigated. No 6-mercaptopurine was formed from azathioprine added to water or plasma and run through the method. The method enables the detection of 2 ng of 6 mercaptopurine in a 1.0-ml plasma sample. Quantitative determinations were done down to 10 ng/ml 6 mercaptopurine in plasma.

  13. Atmospheric pressure gas chromatography–time-of-flight-mass spectrometry (APGC–ToF-MS) for the determination of regulated and emerging contaminants in aqueous samples after stir bar sorptive extraction (SBSE)

    International Nuclear Information System (INIS)

    Pintado-Herrera, Marina G.; González-Mazo, Eduardo; Lara-Martín, Pablo A.

    2014-01-01

    Graphical abstract: Examples of identification of target (triclosan, TCS) and non-target (tributhyl phosphate, TBP) compounds in environmental water samples by APGC–ToF-MS. Some confirmation criteria are shown (i.e. mass spectra, isotopic distribution, and accurate mass). - Highlights: • 102 regulated and emerging contaminants are simultaneously extracted by SBSE. • APGC–ToF-MS is presented as an alternative to EI for the analysis of microcontaminants. • Identification of non-target compounds in environmental matrices is also explored. - Abstract: This work presents the development, optimization and validation of a multi-residue method for the simultaneous determination of 102 contaminants, including fragrances, UV filters, repellents, endocrine disruptors, biocides, polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and several types of pesticides in aqueous matrices. Water samples were processed using stir bar sorptive extraction (SBSE) after the optimization of several parameters: agitation time, ionic strength, presence of organic modifiers, pH, and volume of the derivatizing agent. Target compounds were extracted from the bars by liquid desorption (LD). Separation, identification and quantification of analytes were carried out by gas chromatography (GC) coupled to time-of-flight (ToF-MS) mass spectrometry. A new ionization source, atmospheric pressure gas chromatography (APGC), was tested. The optimized protocol showed acceptable recovery percentages (50–100%) and limits of detection below 1 ng L −1 for most of the compounds. Occurrence of 21 out of 102 analytes was confirmed in several environmental aquatic matrices, including seawater, sewage effluent, river water and groundwater. Non-target compounds such as organophosphorus flame retardants were also identified in real samples by accurate mass measurement of their molecular ions using GC-APGC–ToF-MS. To the best of our knowledge, this is the first time that this

  14. Atmospheric pressure gas chromatography–time-of-flight-mass spectrometry (APGC–ToF-MS) for the determination of regulated and emerging contaminants in aqueous samples after stir bar sorptive extraction (SBSE)

    Energy Technology Data Exchange (ETDEWEB)

    Pintado-Herrera, Marina G.; González-Mazo, Eduardo; Lara-Martín, Pablo A., E-mail: pablo.lara@uca.es

    2014-12-03

    Graphical abstract: Examples of identification of target (triclosan, TCS) and non-target (tributhyl phosphate, TBP) compounds in environmental water samples by APGC–ToF-MS. Some confirmation criteria are shown (i.e. mass spectra, isotopic distribution, and accurate mass). - Highlights: • 102 regulated and emerging contaminants are simultaneously extracted by SBSE. • APGC–ToF-MS is presented as an alternative to EI for the analysis of microcontaminants. • Identification of non-target compounds in environmental matrices is also explored. - Abstract: This work presents the development, optimization and validation of a multi-residue method for the simultaneous determination of 102 contaminants, including fragrances, UV filters, repellents, endocrine disruptors, biocides, polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and several types of pesticides in aqueous matrices. Water samples were processed using stir bar sorptive extraction (SBSE) after the optimization of several parameters: agitation time, ionic strength, presence of organic modifiers, pH, and volume of the derivatizing agent. Target compounds were extracted from the bars by liquid desorption (LD). Separation, identification and quantification of analytes were carried out by gas chromatography (GC) coupled to time-of-flight (ToF-MS) mass spectrometry. A new ionization source, atmospheric pressure gas chromatography (APGC), was tested. The optimized protocol showed acceptable recovery percentages (50–100%) and limits of detection below 1 ng L{sup −1} for most of the compounds. Occurrence of 21 out of 102 analytes was confirmed in several environmental aquatic matrices, including seawater, sewage effluent, river water and groundwater. Non-target compounds such as organophosphorus flame retardants were also identified in real samples by accurate mass measurement of their molecular ions using GC-APGC–ToF-MS. To the best of our knowledge, this is the first time that this

  15. Determination of NH_2 concentration on 3-aminopropyl tri-ethoxy silane layers and cyclopropylamine plasma polymers by liquid-phase derivatization with 5-iodo 2-furaldehyde

    International Nuclear Information System (INIS)

    Manakhov, Anton; Čechal, Jan; Michlíček, Miroslav; Shtansky, Dmitry V.

    2017-01-01

    Highlights: • A new method for primary amines derivatization is proposed and validated. • The chemical structure of APTES layer is studied. • The derivatization by 5-iodo 2-furaldehyde allowed to avoid side reactions in contrast to 4-trifluoromethyl benzaldehyde derivatization. - Abstract: The quantification of concentration of primary amines, e.g. in plasma polymerized layers is a very important task for surface analysis. However, the commonly used procedure, such as gas phase derivatization with benzaldehydes, shows several drawbacks, the most important of which are the side reaction effects. In the present study we propose and validate a liquid phase derivatization using 5-iodo 2-furaldehyde (IFA). It was demonstrated that the content of NH_2 groups can be determined from the atomic concentrations measured by X-ray photoelectron spectroscopy (XPS), in particular from the ratio of I 3d and N 1s peak intensities. First, we demonstrate the method on a prototypical system such as 3-aminopropyl tri-ethoxy silane (APTES) layer. Here the XPS analysis carried out after reaction of APTES layer with IFA gives the fraction of primary amines (NH_2/N) of 38.3 ± 7.9%. Comparing this value with that obtained by N 1s curve fitting of APTES layer giving 40.9 ± 9.5% of amine groups, it can be concluded that all primary amines were derivatized by reaction with IFA. The second system to demonstrate the method comprises cyclopropylamine (CPA) plasma polymers that were free from conjugated imines. In this case the method gives the NH_2 fraction ∼8.5%. This value is closely matching the NH_2/N ratio estimated by 4-trifluoromethyl benzaldehyde (TFBA) derivatization. The reaction of IFA with CPA plasma polymer exhibiting high density of conjugated imines revealed the NH_2/N fraction of ∼10.8%. This value was significantly lower compared to 17.3% estimated by TFBA derivatization. As the overestimated density of primary amines measured by TFBA derivatization is probably

  16. In situ oxidation state profiling of nickel hexacyanoferrate derivatized electrodes using line-imaging Raman spectroscopy and multivariate calibration

    International Nuclear Information System (INIS)

    Haight, S.M.; Schwartz, D.T.

    1999-01-01

    Metal hexacyanoferrate compounds show promise as electrochemically switchable ion exchange materials for use in the cleanup of radioactive wastes such as those found in storage basins and underground tanks at the Department of Energy's Hanford Nuclear Reservation. Reported is the use of line-imaging Raman spectroscopy for the in situ determination of oxidation state profiles in nickel hexacyanoferrate derivatized electrodes under potential control in an electrochemical cell. Line-imaging Raman spectroscopy is used to collect 256 contiguous Raman spectra every ∼5 microm from thin films (ca. 80 nm) formed by electrochemical derivatization of nickel electrodes. The cyanide stretching region of the Raman spectrum of the film is shown to be sensitive to iron oxidation state and is modeled by both univariate and multivariate correlations. Although both correlations fit the calibration set well, the multivariate (principle component regression or PCR) model's predictions of oxidation state are less sensitive to noise in the spectrum, yielding a much smoother oxidation state profile than the univariate model. Oxidation state profiles with spatial resolution of approximately 5 microm are shown for a nickel hexacyanoferrate derivatized electrode in reduced, intermediate, and oxidized states. In situ oxidation state profiles indicate that the 647.1 nm laser illumination photo-oxidizes the derivatized electrodes. This observation is confirmed using photoelectrochemical methods

  17. Establishment of a Charge Reversal Derivatization Strategy to Improve the Ionization Efficiency of Limaprost and Investigation of the Fragmentation Patterns of Limaprost Derivatives Via Exclusive Neutral Loss and Survival Yield Method

    Science.gov (United States)

    Sun, Dong; Meng, Xiangjun; Ren, Tianming; Fawcett, John Paul; Wang, Hualu; Gu, Jingkai

    2018-04-01

    Sensitivity is generally an issue in bioassays of prostaglandins and their synthetic analogs due to their extremely low concentration in vivo. To improve the ionization efficiency of limaprost, an oral prostaglandin E1 (PGE1) synthetic analog, we investigated a charge reversal derivatization strategy in electrospray ionization mass spectrometry (ESI-MS). We established that the cholamine derivative exhibits much greater signal intensity in the positive-ion mode compared with limaprost in the negative ion mode. Collision-induced dissociation (CID) involved exclusive neutral mass loss and positive charge migration to form stable cationic product ions with the positive charge on the limaprost residue rather than on the modifying group. This has the effect of maintaining the efficiency and specificity of multiple reaction monitoring (MRM) and avoiding cross talk. CID fragmentation patterns of other limaprost derivatives allowed us to relate the dissociation tendency of different neutral leaving groups to an internal energy distribution scale based on the survival yield method. Knowledge of the energy involved in the production of stabilized positive ions will potentially assist the selection of suitable derivatization reagents for the analysis of a wide variety of lipid acids. [Figure not available: see fulltext.

  18. Optimizing sample pretreatment for compound-specific stable carbon isotopic analysis of amino sugars in marine sediment

    Science.gov (United States)

    Zhu, R.; Lin, Y.-S.; Lipp, J. S.; Meador, T. B.; Hinrichs, K.-U.

    2014-09-01

    Amino sugars are quantitatively significant constituents of soil and marine sediment, but their sources and turnover in environmental samples remain poorly understood. The stable carbon isotopic composition of amino sugars can provide information on the lifestyles of their source organisms and can be monitored during incubations with labeled substrates to estimate the turnover rates of microbial populations. However, until now, such investigation has been carried out only with soil samples, partly because of the much lower abundance of amino sugars in marine environments. We therefore optimized a procedure for compound-specific isotopic analysis of amino sugars in marine sediment, employing gas chromatography-isotope ratio mass spectrometry. The whole procedure consisted of hydrolysis, neutralization, enrichment, and derivatization of amino sugars. Except for the derivatization step, the protocol introduced negligible isotopic fractionation, and the minimum requirement of amino sugar for isotopic analysis was 20 ng, i.e., equivalent to ~8 ng of amino sugar carbon. Compound-specific stable carbon isotopic analysis of amino sugars obtained from marine sediment extracts indicated that glucosamine and galactosamine were mainly derived from organic detritus, whereas muramic acid showed isotopic imprints from indigenous bacterial activities. The δ13C analysis of amino sugars provides a valuable addition to the biomarker-based characterization of microbial metabolism in the deep marine biosphere, which so far has been lipid oriented and biased towards the detection of archaeal signals.

  19. Deriving Stellar Masses for the ALFALFA α.100 Sample

    Science.gov (United States)

    Hess, Logan; Cornell 2017 Summer REU

    2018-01-01

    For this project, we explore different methods of deriving the stellar masses of galaxies in the ALFALFA (Arecibo Legacy Fast ALFA) α.100 survey. In particular, we measure the effectiveness of SED (Spectral Energy Distribution) on the sample. SED fitting was preformed by MAGPHYS (Multi-wavelength Analysis of Galaxy Physical Properties), utilizing a wide range of photometry in the UV, optical, and IR bands. Photometry was taken from GALAX GR6/7 (UV), SDSS DR13 (optical), WISE All-Sky (near-IR), and Herschel PACS/SPIRE (far-IR). The efficiency of SED fitting increases with a broader range of photometry, however detection rates varied significantly across the different bands. Using a more “comprehensive” sample of galaxies, the GSWLC-A (GALAX, SDSS, WISE Legacy Catalog All-Sky Survey), we aimed to measure which combination of bands provided the largest sample return with the lowest amount of uncertainty, which could then be used to estimate the masses of the galaxies in the α.100 sample.

  20. HICOSMO - cosmology with a complete sample of galaxy clusters - I. Data analysis, sample selection and luminosity-mass scaling relation

    Science.gov (United States)

    Schellenberger, G.; Reiprich, T. H.

    2017-08-01

    The X-ray regime, where the most massive visible component of galaxy clusters, the intracluster medium, is visible, offers directly measured quantities, like the luminosity, and derived quantities, like the total mass, to characterize these objects. The aim of this project is to analyse a complete sample of galaxy clusters in detail and constrain cosmological parameters, like the matter density, Ωm, or the amplitude of initial density fluctuations, σ8. The purely X-ray flux-limited sample (HIFLUGCS) consists of the 64 X-ray brightest galaxy clusters, which are excellent targets to study the systematic effects, that can bias results. We analysed in total 196 Chandra observations of the 64 HIFLUGCS clusters, with a total exposure time of 7.7 Ms. Here, we present our data analysis procedure (including an automated substructure detection and an energy band optimization for surface brightness profile analysis) that gives individually determined, robust total mass estimates. These masses are tested against dynamical and Planck Sunyaev-Zeldovich (SZ) derived masses of the same clusters, where good overall agreement is found with the dynamical masses. The Planck SZ masses seem to show a mass-dependent bias to our hydrostatic masses; possible biases in this mass-mass comparison are discussed including the Planck selection function. Furthermore, we show the results for the (0.1-2.4) keV luminosity versus mass scaling relation. The overall slope of the sample (1.34) is in agreement with expectations and values from literature. Splitting the sample into galaxy groups and clusters reveals, even after a selection bias correction, that galaxy groups exhibit a significantly steeper slope (1.88) compared to clusters (1.06).

  1. Simultaneous Analysis of 3-MCPD and 1,3-DCP in Asian Style Sauces Using QuEChERS Extraction and Gas Chromatography–Triple Quadrupole Mass Spectrometry

    Science.gov (United States)

    Genualdi, Susan; Nyman, Patricia; DeJager, Lowri

    2017-01-01

    Acid hydrolyzed vegetable protein (aHVP) is used for flavoring a wide variety of foods and also in the production of nonfermented soy sauce. During the production of aHVP, chloropropanols including 3-monochloropropane-1,2-diol (3-MCPD) and 1,3 dichloropropane-2-ol (1,3-DCP) can be formed through the reaction of the hydrochloric acid catalyst and residual fat and the reaction of 3-MCPD with acetic acid, respectively. 3-MCPD is a carcinogen, and 1,3-DCP has been classified as a genotoxic carcinogen. The European Union (EU) has set a maximum concentration of 0.02 mg/kg of 3-MCPD in aHVP, and the Food and Drug Administration (FDA) set a guidance limit of 1 mg/kg of 3-MCPD in aHVP. 1,3-DCP is not an approved food additive, and the Joint FAO/WHO Expert Committee on Food Additives (JEFCA) has set a limit at 0.005 mg/kg, which is close to the estimated method detection limit. Currently there are few analytical methods for the simultaneous determination of 3-MCPD and 1,3-DCP without derivatization due to differences in their physical chemical properties and reactivity. A new method was developed using QuEChERS (quick, easy, cheap, effective, rugged, and safe) with direct analysis of the extract without derivatization using gas chromatography–triple quadrupole mass spectrometry (GC-QQQ). Additionally, a market sampling of 60 soy sauce samples was performed in 2015 to determine if concentrations have changed since the FDA limit was set in 2008. The sampling results were compared between the new QuEChERS method and a method using phenylboronic acid (PBA) as a derivatizing agent for 3-MCPD analysis. The concentrations of 3-MCPD detected in soy sauce samples collected in 2015 (3-MCPD below current regulatory limits PMID:28064506

  2. Simultaneous Analysis of 3-MCPD and 1,3-DCP in Asian Style Sauces Using QuEChERS Extraction and Gas Chromatography-Triple Quadrupole Mass Spectrometry.

    Science.gov (United States)

    Genualdi, Susan; Nyman, Patricia; DeJager, Lowri

    2017-02-01

    Acid hydrolyzed vegetable protein (aHVP) is used for flavoring a wide variety of foods and also in the production of nonfermented soy sauce. During the production of aHVP, chloropropanols including 3-monochloropropane-1,2-diol (3-MCPD) and 1,3 dichloropropane-2-ol (1,3-DCP) can be formed through the reaction of the hydrochloric acid catalyst and residual fat and the reaction of 3-MCPD with acetic acid, respectively. 3-MCPD is a carcinogen, and 1,3-DCP has been classified as a genotoxic carcinogen. The European Union (EU) has set a maximum concentration of 0.02 mg/kg of 3-MCPD in aHVP, and the Food and Drug Administration (FDA) set a guidance limit of 1 mg/kg of 3-MCPD in aHVP. 1,3-DCP is not an approved food additive, and the Joint FAO/WHO Expert Committee on Food Additives (JEFCA) has set a limit at 0.005 mg/kg, which is close to the estimated method detection limit. Currently there are few analytical methods for the simultaneous determination of 3-MCPD and 1,3-DCP without derivatization due to differences in their physical chemical properties and reactivity. A new method was developed using QuEChERS (quick, easy, cheap, effective, rugged, and safe) with direct analysis of the extract without derivatization using gas chromatography-triple quadrupole mass spectrometry (GC-QQQ). Additionally, a market sampling of 60 soy sauce samples was performed in 2015 to determine if concentrations have changed since the FDA limit was set in 2008. The sampling results were compared between the new QuEChERS method and a method using phenylboronic acid (PBA) as a derivatizing agent for 3-MCPD analysis. The concentrations of 3-MCPD detected in soy sauce samples collected in 2015 (3-MCPD below current regulatory limits.

  3. Investigating sub-2 μm particle stationary phase supercritical fluid chromatography coupled to mass spectrometry for chemical profiling of chamomile extracts.

    Science.gov (United States)

    Jones, Michael D; Avula, Bharathi; Wang, Yan-Hong; Lu, Lu; Zhao, Jianping; Avonto, Cristina; Isaac, Giorgis; Meeker, Larry; Yu, Kate; Legido-Quigley, Cristina; Smith, Norman; Khan, Ikhlas A

    2014-10-17

    Roman and German chamomile are widely used throughout the world. Chamomiles contain a wide variety of active constituents including sesquiterpene lactones. Various extraction techniques were performed on these two types of chamomile. A packed-column supercritical fluid chromatography-mass spectrometry method was designed for the identification of sesquiterpenes and other constituents from chamomile extracts with no derivatization step prior to analysis. Mass spectrometry detection was achieved by using electrospray ionization. All of the compounds of interest were separated within 15 min. The chamomile extracts were analyzed and compared for similarities and distinct differences. Multivariate statistical analysis including principal component analysis and orthogonal partial least squares-discriminant analysis (OPLS-DA) were used to differentiate between the chamomile samples. German chamomile samples confirmed the presence of cis- and trans-tonghaosu, chrysosplenols, apigenin diglucoside whereas Roman chamomile samples confirmed the presence of apigenin, nobilin, 1,10-epioxynobilin, and hydroxyisonobilin. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Resonance ionization mass spectrometry system for measurement of environmental samples

    International Nuclear Information System (INIS)

    Pibida, L.; McMahon, C.A.; Noertershaeuser, W.; Bushaw, B.A.

    2002-01-01

    A resonance ionization mass spectrometry (RIMS) system has been developed at the National Institute of Standards and Technology (NIST) for sensitive and selective determination of radio-cesium in the environment. The overall efficiency was determined to be 4x10-7 with a combined (laser and mass spectrometer) selectivity of 108 for both 135Cs and 137Cs with respect to 133Cs. RIMS isotopic ratio measurements of 135Cs/ 137Cs were performed on a nuclear fuel burn-up sample and compared to measurements on a similar system at Pacific Northwest National Laboratory (PNNL) and to conventional thermal ionization mass spectrometry (TIMS). Results of preliminary RIMS investigations on a freshwater lake sediment sample are also discussed

  5. Development and application of a sampling method for the determination of reactive halogen species in volcanic gas emissions

    Science.gov (United States)

    Rüdiger, Julian; Bobrowski, Nicole; Liotta, Marcello; Hoffmann, Thorsten

    2017-04-01

    Volcanoes are a potential large source of several reactive atmospheric trace gases including sulfur and halogen containing species. Besides the importance for atmospheric chemistry, the detailed knowledge of halogen chemistry in volcanic plumes can help to get insights into subsurface processes. In this study a gas diffusion denuder sampling method, using a 1,3,5-trimethoxybenzene (1,3,5-TMB) coating for the derivatization of reactive halogen species (RHS), was characterized by dilution chamber experiments. The coating proved to be suitable to collect selectively gaseous bromine species with oxidation states (OS) of +1 or 0 (such as Br2, BrCl, BrO(H) and BrONO2), while being ignorant to HBr (OS -1). The reaction of 1,3,5-TMB with reactive bromine species gives 1-bromo-2,4,6-trimethoxybenzene (1-bromo-2,4,6-TMB) - other halogens give corresponding products. Solvent elution of the derivatized analytes and subsequent analysis with gas chromatography mass spectrometry gives detection limits of 10 ng or less for Br2, Cl2, and I2. In 2015 the method was applied on volcanic gas plumes at Mt. Etna (Italy) giving reactive bromine mixing ratios from 0.8 ppbv to 7.0 ppbv. Total bromine mixing ratios of 4.7 ppbv to 27.5 ppbv were obtained by simultaneous alkaline trap sampling (by a Raschig-tube) followed by analysis with ion chromatography and inductively coupled plasma mass spectrometry. This leads to the first results of in-situ measured reactive bromine to total bromine ratios, spanning a range between 12±1 % and 36±2 %. Our finding is in an agreement with previous model studies, which imply values < 44 % for plume ages < 1 minute, which is consistent with the assumed plume age at the sampling sites.

  6. Determination of total cyanide in soil by isotope dilution GC/MS following pentafluorobenzyl derivatization

    Energy Technology Data Exchange (ETDEWEB)

    Campanella, Beatrice, E-mail: beatrice.campanella@pi.iccom.cnr.it [Università di Pisa, Dipartimento di Chimica e Chimica Industriale, via Moruzzi 13, 56124 Pisa (Italy); Consiglio Nazionale delle Ricerche (CNR), Istituto di Chimica dei Composti Organometallici, UOS di Pisa, via Moruzzi 1, 56124 Pisa (Italy); Biancalana, Lorenzo [Università di Pisa, Dipartimento di Chimica e Chimica Industriale, via Moruzzi 13, 56124 Pisa (Italy); D' Ulivo, Lucia [National Research Council of Canada, 1200 Montreal Road, Ottawa, ON K1A 0R6 (Canada); Onor, Massimo; Bramanti, Emilia [Consiglio Nazionale delle Ricerche (CNR), Istituto di Chimica dei Composti Organometallici, UOS di Pisa, via Moruzzi 1, 56124 Pisa (Italy); Mester, Zoltan; Pagliano, Enea [National Research Council of Canada, 1200 Montreal Road, Ottawa, ON K1A 0R6 (Canada)

    2017-04-08

    The high toxicity of cyanide, along with its widespread industrial use, has fuelled interest in the development of analytical methods for its determination in complex matrices. In this study, we propose a novel approach for the measurement of total cyanide in soil samples based on single-step derivatization with pentafluorobenzyl bromide (F{sub 5}Bn−Br) followed by quantitation with gas chromatography mass spectrometry in negative chemical ionization mode. The reaction between CN{sup −} and F{sub 5}Bn−Br resulted in the identification of several derivatives such as F{sub 5}Bn−CN, (F{sub 5}Bn)(F{sub 5}Ph)CH−CN, and (F{sub 5}Bn){sub 2}(F{sub 5}Ph)C−CN. The relative proportion between such compounds was dependent on experimental conditions. When a 100 μL aliquot of an alkaline-aqueous extract was reacted with 700 μL of 1.3% F{sub 5}Bn−Br in acetone, the tri-alkylated derivative was the most abundant. In such conditions a detection limit of 0.5 ng/g of CN{sup −} was attained. Soil samples were initially spiked with an alkaline solution of K{sup 13}C{sup 15}N internal standard and suspended in 7.5% aqueous NaOH. Determination of total cyanide was achieved by digestion of the alkaline extract with H{sub 3}PO{sub 4} to produce HCN which was then trapped in 0.1% NaOH in a sealed double vial system, followed by reaction with F{sub 5}Bn−Br. Isotope dilution calibration was chosen for quantitation, and the validity of the novel method was demonstrated by analysis of soil Certified Reference Materials (CRMs) and by spike recovery tests. - Highlights: • A cost-effective, fast and simple method for determination of total cyanide in soil is presented. • A new micro-distillation strategy was developed overcoming the problems of a conventional distillation. • Negative chemical ionization-mass spectrometer has been exploited to obtain a high sensitivity and specificity. • High accuracy was attained for the analysis of certified reference materials with

  7. Improving methodological aspects of the analysis of five regulated haloacetic acids in water samples by solid-phase extraction, ion-pair liquid chromatography and electrospray tandem mass spectrometry.

    Science.gov (United States)

    Prieto-Blanco, M C; Alpendurada, M F; López-Mahía, P; Muniategui-Lorenzo, S; Prada-Rodríguez, D; Machado, S; Gonçalves, C

    2012-05-30

    Haloacetic acids (HAAs) are organic pollutants originated from the drinking water disinfection process, which ought to be controlled and minimized. In this work a method for monitoring haloacetic acids (HAAs) in water samples is proposed, which can be used in quality control laboratories using the techniques most frequently available. Among its main advantages we may highlight its automated character, including minimal steps of sample preparation, and above all, its improved selectivity and sensitivity in the analysis of real samples. Five haloacetic acids (HAA5) were analyzed using solid-phase extraction (SPE) combined with ion-pair liquid chromatography and tandem mass spectrometry. For the optimization of the chromatographic separation, two amines (triethylamine, TEA and dibutylamine, DBA) as ion pair reagents were compared, and a better selectivity and sensitivity was obtained using DBA, especially for monohaloacetic acids. SPE conditions were optimized using different polymeric adsorbents. The electrospray source parameters were studied for maximum precursor ion accumulation, while the collision cell energy of the triple quadrupole mass spectrometer was adjusted for optimum fragmentation. Precursor ions detected were deprotonated, dimeric and decarboxylated ions. The major product ions formed were: ionized halogen atom (chloride and bromide) and decarboxylated ions. After enrichment of the HAAs in Lichrolut EN adsorbent, the limits of detection obtained by LC-MS/MS analysis (between 0.04 and 0.3 ng mL(-1)) were comparable to those obtained by GC-MS after derivatization. Linearity with good correlation coefficients was obtained over two orders of magnitude irrespective of the compound. Adequate recoveries were achieved (60-102%), and the repeatability and intermediate precision were in the range of 2.4-6.6% and 3.8-14.8%, respectively. In order to demonstrate the usefulness of the method for routine HAAs monitoring, different types of water samples were

  8. Ion sampling and transport in Inductively Coupled Plasma Mass Spectrometry

    Science.gov (United States)

    Farnsworth, Paul B.; Spencer, Ross L.

    2017-08-01

    Quantitative accuracy and high sensitivity in inductively coupled plasma mass spectrometry (ICP-MS) depend on consistent and efficient extraction and transport of analyte ions from an inductively coupled plasma to a mass analyzer, where they are sorted and detected. In this review we examine the fundamental physical processes that control ion sampling and transport in ICP-MS and compare the results of theory and computerized models with experimental efforts to characterize the flow of ions through plasma mass spectrometers' vacuum interfaces. We trace the flow of ions from their generation in the plasma, into the sampling cone, through the supersonic expansion in the first vacuum stage, through the skimmer, and into the ion optics that deliver the ions to the mass analyzer. At each stage we consider idealized behavior and departures from ideal behavior that affect the performance of ICP-MS as an analytical tool.

  9. Direct Visualization of Neurotransmitters in Rat Brain Slices by Desorption Electrospray Ionization Mass Spectrometry Imaging (DESI - MS)

    Science.gov (United States)

    Fernandes, Anna Maria A. P.; Vendramini, Pedro H.; Galaverna, Renan; Schwab, Nicolas V.; Alberici, Luciane C.; Augusti, Rodinei; Castilho, Roger F.; Eberlin, Marcos N.

    2016-12-01

    Mass spectrometry imaging (MSI) of neurotransmitters has so far been mainly performed by matrix-assisted laser desorption/ionization (MALDI) where derivatization reagents, deuterated matrix and/or high resolution, or tandem MS have been applied to circumvent problems with interfering ion peaks from matrix and from isobaric species. We herein describe the application of desorption electrospray ionization mass spectrometry imaging (DESI)-MSI in rat brain coronal and sagittal slices for direct spatial monitoring of neurotransmitters and choline with no need of derivatization reagents and/or deuterated materials. The amino acids γ-aminobutyric (GABA), glutamate, aspartate, serine, as well as acetylcholine, dopamine, and choline were successfully imaged using a commercial DESI source coupled to a hybrid quadrupole-Orbitrap mass spectrometer. The spatial distribution of the analyzed compounds in different brain regions was determined. We conclude that the ambient matrix-free DESI-MSI is suitable for neurotransmitter imaging and could be applied in studies that involve evaluation of imbalances in neurotransmitters levels.

  10. Field Sample Preparation Method Development for Isotope Ratio Mass Spectrometry

    International Nuclear Information System (INIS)

    Leibman, C.; Weisbrod, K.; Yoshida, T.

    2015-01-01

    Non-proliferation and International Security (NA-241) established a working group of researchers from Los Alamos National Laboratory (LANL), Pacific Northwest National Laboratory (PNNL) and Savannah River National Laboratory (SRNL) to evaluate the utilization of in-field mass spectrometry for safeguards applications. The survey of commercial off-the-shelf (COTS) mass spectrometers (MS) revealed no instrumentation existed capable of meeting all the potential safeguards requirements for performance, portability, and ease of use. Additionally, fieldable instruments are unlikely to meet the International Target Values (ITVs) for accuracy and precision for isotope ratio measurements achieved with laboratory methods. The major gaps identified for in-field actinide isotope ratio analysis were in the areas of: 1. sample preparation and/or sample introduction, 2. size reduction of mass analyzers and ionization sources, 3. system automation, and 4. decreased system cost. Development work in 2 through 4, numerated above continues, in the private and public sector. LANL is focusing on developing sample preparation/sample introduction methods for use with the different sample types anticipated for safeguard applications. Addressing sample handling and sample preparation methods for MS analysis will enable use of new MS instrumentation as it becomes commercially available. As one example, we have developed a rapid, sample preparation method for dissolution of uranium and plutonium oxides using ammonium bifluoride (ABF). ABF is a significantly safer and faster alternative to digestion with boiling combinations of highly concentrated mineral acids. Actinides digested with ABF yield fluorides, which can then be analyzed directly or chemically converted and separated using established column chromatography techniques as needed prior to isotope analysis. The reagent volumes and the sample processing steps associated with ABF sample digestion lend themselves to automation and field

  11. Determination of NH{sub 2} concentration on 3-aminopropyl tri-ethoxy silane layers and cyclopropylamine plasma polymers by liquid-phase derivatization with 5-iodo 2-furaldehyde

    Energy Technology Data Exchange (ETDEWEB)

    Manakhov, Anton, E-mail: ant-manahov@ya.ru [National University of Science and Technology “MISiS”, Leninsky pr. 4, Moscow 119049 (Russian Federation); RG Plasma Technologies, CEITEC—Central European Institute of Technology, Masaryk University, Kotlářská, 2, 61137 Brno (Czech Republic); Čechal, Jan [CEITEC—Central European Institute of Technology, Brno University of Technology, Purkyňova 123, 612 00 Brno (Czech Republic); Institute of Physical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno (Czech Republic); Michlíček, Miroslav [RG Plasma Technologies, CEITEC—Central European Institute of Technology, Masaryk University, Kotlářská, 2, 61137 Brno (Czech Republic); Department of Physical Electronics, Faculty of Science, Masaryk University, Kotlářská 2, 61137 Brno (Czech Republic); Shtansky, Dmitry V. [National University of Science and Technology “MISiS”, Leninsky pr. 4, Moscow 119049 (Russian Federation)

    2017-08-31

    Highlights: • A new method for primary amines derivatization is proposed and validated. • The chemical structure of APTES layer is studied. • The derivatization by 5-iodo 2-furaldehyde allowed to avoid side reactions in contrast to 4-trifluoromethyl benzaldehyde derivatization. - Abstract: The quantification of concentration of primary amines, e.g. in plasma polymerized layers is a very important task for surface analysis. However, the commonly used procedure, such as gas phase derivatization with benzaldehydes, shows several drawbacks, the most important of which are the side reaction effects. In the present study we propose and validate a liquid phase derivatization using 5-iodo 2-furaldehyde (IFA). It was demonstrated that the content of NH{sub 2} groups can be determined from the atomic concentrations measured by X-ray photoelectron spectroscopy (XPS), in particular from the ratio of I 3d and N 1s peak intensities. First, we demonstrate the method on a prototypical system such as 3-aminopropyl tri-ethoxy silane (APTES) layer. Here the XPS analysis carried out after reaction of APTES layer with IFA gives the fraction of primary amines (NH{sub 2}/N) of 38.3 ± 7.9%. Comparing this value with that obtained by N 1s curve fitting of APTES layer giving 40.9 ± 9.5% of amine groups, it can be concluded that all primary amines were derivatized by reaction with IFA. The second system to demonstrate the method comprises cyclopropylamine (CPA) plasma polymers that were free from conjugated imines. In this case the method gives the NH{sub 2} fraction ∼8.5%. This value is closely matching the NH{sub 2}/N ratio estimated by 4-trifluoromethyl benzaldehyde (TFBA) derivatization. The reaction of IFA with CPA plasma polymer exhibiting high density of conjugated imines revealed the NH{sub 2}/N fraction of ∼10.8%. This value was significantly lower compared to 17.3% estimated by TFBA derivatization. As the overestimated density of primary amines measured by TFBA

  12. In matrix derivatization of trichloroethylene metabolites in human plasma with methyl chloroformate and their determination by solid-phase microextraction-gas chromatography-electron capture detector.

    Science.gov (United States)

    Mudiam, Mohana Krishna Reddy; Jain, Rajeev; Varshney, Meenu; Ch, Ratnasekhar; Chauhan, Abhishek; Goyal, Sudhir Kumar; Khan, Haider A; Murthy, R C

    2013-04-15

    Trichloroethylene (TCE) is a common industrial chemical that has been widely used as metal degreaser and for many industrial purposes. In humans, TCE is metabolized into dichloroacetic acid (DCA), trichloroacetic acid (TCA) and trichloroethanol (TCOH). A simple and rapid method has been developed for the quantitative determination of TCE metabolites. The procedure involves the in situ derivatization of TCE metabolites with methyl chloroformate (MCF) directly in diluted plasma samples followed by extraction and analysis with solid-phase microextraction (SPME) coupled to gas chromatography-electron capture detector (GC-ECD). Factors which can influence the efficiency of derivatization such as amount of MCF and pyridine (PYR), ratio of water/methanol were optimized. The factors which can affect the extraction efficiencies of SPME were screened using 2(7-4) Placket-Burman Design (PBD). A central composite design (CCD) was then applied to further optimize the most significant factors for optimum SPME extraction. The optimum factors for the SPME extraction were found to be 562.5mg of NaCl, pH at 1 and an extraction time of 22 min. Recoveries and detection limits of all three analytes in plasma were found to be in the range of 92.69-97.55% and 0.036-0.068 μg mL(-1) of plasma, respectively. The correlation coefficients were found to be in the range of 0.990-0.995. The intra- and inter-day precisions for TCE metabolites were found to be in the range of 2.37-4.81% and 5.13-7.61%, respectively. The major advantage of this method is that MCF derivatization allows conversion of TCE metabolites into their methyl esters in very short time (≤30 s) at room temperature directly in the plasma samples, thus makes it a solventless analysis. The method developed was successfully applied to the plasma samples of humans exposed to TCE. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. An UPLC-ESI-MS/MS Assay Using 6-Aminoquinolyl-N-Hydroxysuccinimidyl Carbamate Derivatization for Targeted Amino Acid Analysis: Application to Screening of Arabidopsis thaliana Mutants

    Directory of Open Access Journals (Sweden)

    Carolina Salazar

    2012-07-01

    Full Text Available In spite of the large arsenal of methodologies developed for amino acid assessment in complex matrices, their implementation in metabolomics studies involving wide-ranging mutant screening is hampered by their lack of high-throughput, sensitivity, reproducibility, and/or wide dynamic range. In response to the challenge of developing amino acid analysis methods that satisfy the criteria required for metabolomic studies, improved reverse-phase high-performance liquid chromatography-mass spectrometry (RPHPLC-MS methods have been recently reported for large-scale screening of metabolic phenotypes. However, these methods focus on the direct analysis of underivatized amino acids and, therefore, problems associated with insufficient retention and resolution are observed due to the hydrophilic nature of amino acids. It is well known that derivatization methods render amino acids more amenable for reverse phase chromatographic analysis by introducing highly-hydrophobic tags in their carboxylic acid or amino functional group. Therefore, an analytical platform that combines the 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC pre-column derivatization method with ultra performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI-MS/MS is presented in this article. For numerous reasons typical amino acid derivatization methods would be inadequate for large scale metabolic projects. However, AQC derivatization is a simple, rapid and reproducible way of obtaining stable amino acid adducts amenable for UPLC-ESI-MS/MS and the applicability of the method for high-throughput metabolomic analysis in Arabidopsis thaliana is demonstrated in this study. Overall, the major advantages offered by this amino acid analysis method include high-throughput, enhanced sensitivity and selectivity; characteristics that showcase its utility for the rapid screening of the preselected plant metabolites without compromising the quality of the

  14. An UPLC-ESI-MS/MS Assay Using 6-Aminoquinolyl-N-Hydroxysuccinimidyl Carbamate Derivatization for Targeted Amino Acid Analysis: Application to Screening of Arabidopsis thaliana Mutants.

    Science.gov (United States)

    Salazar, Carolina; Armenta, Jenny M; Shulaev, Vladimir

    2012-07-06

    In spite of the large arsenal of methodologies developed for amino acid assessment in complex matrices, their implementation in metabolomics studies involving wide-ranging mutant screening is hampered by their lack of high-throughput, sensitivity, reproducibility, and/or wide dynamic range. In response to the challenge of developing amino acid analysis methods that satisfy the criteria required for metabolomic studies, improved reverse-phase high-performance liquid chromatography-mass spectrometry (RPHPLC-MS) methods have been recently reported for large-scale screening of metabolic phenotypes. However, these methods focus on the direct analysis of underivatized amino acids and, therefore, problems associated with insufficient retention and resolution are observed due to the hydrophilic nature of amino acids. It is well known that derivatization methods render amino acids more amenable for reverse phase chromatographic analysis by introducing highly-hydrophobic tags in their carboxylic acid or amino functional group. Therefore, an analytical platform that combines the 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) pre-column derivatization method with ultra performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI-MS/MS) is presented in this article. For numerous reasons typical amino acid derivatization methods would be inadequate for large scale metabolic projects. However, AQC derivatization is a simple, rapid and reproducible way of obtaining stable amino acid adducts amenable for UPLC-ESI-MS/MS and the applicability of the method for high-throughput metabolomic analysis in Arabidopsis thaliana is demonstrated in this study. Overall, the major advantages offered by this amino acid analysis method include high-throughput, enhanced sensitivity and selectivity; characteristics that showcase its utility for the rapid screening of the preselected plant metabolites without compromising the quality of the metabolic data. The

  15. Influence of the tip mass on the tip-sample interactions in TM-AFM

    Energy Technology Data Exchange (ETDEWEB)

    Pishkenari, Hossein Nejat, E-mail: nejat@mech.sharif.edu [Nano-Robotics Laboratory, Center of Excellence in Design, Robotics and Automation, School of Mechanical Engineering, Sharif University of Technology, Tehran, P.O. Box 11365-9465 (Iran, Islamic Republic of); Meghdari, Ali [Nano-Robotics Laboratory, Center of Excellence in Design, Robotics and Automation, School of Mechanical Engineering, Sharif University of Technology, Tehran, P.O. Box 11365-9465 (Iran, Islamic Republic of)

    2011-07-15

    This paper focuses on the influences of the tip mass ratio (the ratio of the tip mass to the cantilever mass), on the excitation of higher oscillation eigenmodes and also on the tip-sample interaction forces in tapping mode atomic force microscopy (TM-AFM). A precise model for the cantilever dynamics capable of accurate simulations is essential for the investigation of the tip mass effects on the interaction forces. In the present work, the finite element method (FEM) is used for modeling the AFM cantilever to consider the oscillations of higher eigenmodes oscillations. In addition, molecular dynamics (MD) is used to calculate precise data for the tip-sample force as a function of tip vertical position with respect to the sample. The results demonstrate that in the presence of nonlinear tip-sample interaction forces, the tip mass ratio plays a significant role in the excitations of higher eigenmodes and also in the normal force applied on the surface. Furthermore, it has been shown that the difference between responses of the FEM and point-mass models in different system operational conditions is highly affected by the tip mass ratio. -- Highlights: {yields} A strong correlation exists between the tip mass ratio and the 18th harmonic amplitude. {yields} Near the critical tip mass ratio a small change in the tip mass may lead to a significant force change. {yields} Inaccuracy of the lumped model depends significantly on the tip mass ratio.

  16. A new combined method of stable isotope-labeling derivatization-ultrasound-assisted dispersive liquid-liquid microextraction for the determination of neurotransmitters in rat brain microdialysates by ultra high performance liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Zheng, Longfang; Zhao, Xian-En; Zhu, Shuyun; Tao, Yanduo; Ji, Wenhua; Geng, Yanling; Wang, Xiao; Chen, Guang; You, Jinmao

    2017-06-01

    In this work, for the first time, a new hyphenated technique of stable isotope-labeling derivatization-ultrasound-assisted dispersive liquid-liquid microextraction has been developed for the simultaneous determination of monoamine neurotransmitters (MANTs) and their biosynthesis precursors and metabolites. The developed method was based on ultra high performance liquid chromatography tandem mass spectrometry detection using multiple-reaction monitoring mode. A pair of mass spectrometry sensitizing reagents, d 0 -10-methyl-acridone-2-sulfonyl chloride and d 3 -10-methyl-acridone-2-sulfonyl chloride, as stable isotope probes was utilized to facilely label neurotransmitters, respectively. The heavy labeled MANTs standards were prepared and used as internal standards for quantification to minimize the matrix effects in mass spectrometry analysis. Low toxic bromobenzene (extractant) and acetonitrile (dispersant) were utilized in microextraction procedure. Under the optimized conditions, good linearity was observed with the limits of detection (S/N>3) and limits of quantification (S/N>10) in the range of 0.002-0.010 and 0.015-0.040nmol/L, respectively. Meanwhile, it also brought acceptable precision (4.2-8.8%, peak area RSDs %) and accuracy (recovery, 96.9-104.1%) results. This method was successfully applied to the simultaneous determination of monoamine neurotransmitters and their biosynthesis precursors and metabolites in rat brain microdialysates of Parkinson's disease and normal rats. This provided a new method for the neurotransmitters related studies in the future. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Determination of autoinducer-2 in biological samples by high-performance liquid chromatography with fluorescence detection using pre-column derivatization.

    Science.gov (United States)

    Song, Xiang-Ning; Qiu, Hai-Bin; Xiao, Xiang; Cheng, Yuan-Yuan; Li, Wen-Wei; Sheng, Guo-Ping; Li, Xiao-Yan; Yu, Han-Qing

    2014-09-26

    Autoinducer-2 (AI-2), as a small-molecular-weight organic molecule secreted and perceived by various bacteria, enables intra- and inter-species communications. Quantitative determination of AI-2 is essential for exploring the bacterial AI-2-related physiological and biochemical processes. However, current strategies for sensitive detection of AI-2 require sophisticated instruments and complicated procedures. In this work, on the basis of the derivatization of AI-2 with 2,3-diaminonaphthalene, a simple, sensitive and cost-effective high-performance liquid chromatography with fluorescence detector (HPLC-FLD) method is developed for the quantitative detection of AI-2. Under the optimized conditions, this method had a broad linear range of 10-14,000 ng/ml (R(2)=0.9999), and a low detection limit of 1.0 ng/ml. Furthermore, the effectiveness of this approach was further validated through measuring the AI-2 concentrations in the cell-free culture supernatants of both Escherichia coli and Vibrio harveyi. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Internal calibration on adjacent samples (InCAS) with Fourier transform mass spectrometry.

    Science.gov (United States)

    O'Connor, P B; Costello, C E

    2000-12-15

    Using matrix-assisted laser desorption/ionization (MAL DI) on a trapped ion mass spectrometer such as a Fourier transform mass spectrometer (FTMS) allows accumulation of ions in the cell from multiple laser shots prior to detection. If ions from separate MALDI samples are accumulated simultaneously in the cell, ions from one sample can be used to calibrate ions from the other sample. Since the ions are detected simultaneously in the cell, this is, in effect, internal calibration, but there are no selective desorption effects in the MALDI source. This method of internal calibration with adjacent samples is demonstrated here on cesium iodide clusters, peptides, oligosaccharides, poly(propylene glycol), and fullerenes and provides typical FTMS internal calibration mass accuracy of < 1 ppm.

  19. A rapid screening procedure for the analysis of proliferation compounds in complex matrices using solid phase microextraction (SPME) and SPME with in-situ derivatization

    International Nuclear Information System (INIS)

    Alcaraz, A.; Hulsey, S.S.; Andresen, B.D.

    1995-01-01

    A variety of methods have been established using advanced chromatographic techniques and new detection systems for the analysis of chemical signatures associated with nuclear and chemical weapon (CW) proliferation. Most of these analytical methods are used in the laboratory and seldom applied in the field. The Chemical Weapons Convention (an international treaty to ban chemical weapons) may require the rapid on-site analysis of environmental samples which contain CW agents, their precursors, and/or their degradation products. In addition to the fact that certain countries are involved in CW non-compliance, there is a current uncertainty regarding nuclear proliferation. This also creates new demands on sample work-up and analytical instrumentation use in the field. The isolation and identification of unique chemical signatures in complex samples such as soils, waste tanks, and decontamination solutions would determine non-compliance. However, a primary area of detection research continues to be sample preparation. Most of the established sample cleanup technologies involve liquid/liquid, Soxhlet, or most recently, solid phase extraction (SPE). Despite the success of these traditional sample preparation techniques, they are time consuming and require multi-step procedures (especially when preparing samples for gas chromatographic mass-spectrometric analysis). The goal of this work is to demonstrate the advantages of utilizing SPME and SPME in-situ derivatization techniques to eliminate time consuming steps necessary to prepare a sample for on-site GC-MS. The authors' approach was to compare two SPME fibers and to develop methods to facilitate the isolation of polar and moderately polar proliferation compounds from complex environmental samples. This work will help to evaluate current SPME technologies for use during on-site environmental monitoring analysis

  20. Trends in sample preparation 2002. Development and application. Book of abstracts

    International Nuclear Information System (INIS)

    Wenzl, T.; Eberl, M.; Zischka, M.; Knapp, G.

    2002-01-01

    This conference comprised topics dealing with sample preparation such as: sample decomposition, solvent extraction, derivatization techniques and uncertainty in sample preparation. In particular microwave assisted sample preparation techniques and equipment were discussed. The papers were organized under the general topics: trace element analysis, trace analysis of organic compounds, high performance instrumentation in sample preparation, speciation analysis and posters session. Those papers of INIS interest are cited individually. (nevyjel)

  1. Trends in sample preparation 2002. Development and application. Book of abstracts

    Energy Technology Data Exchange (ETDEWEB)

    Wenzl, T; Eberl, M; Zischka, M; Knapp, G [eds.

    2002-07-01

    This conference comprised topics dealing with sample preparation such as: sample decomposition, solvent extraction, derivatization techniques and uncertainty in sample preparation. In particular microwave assisted sample preparation techniques and equipment were discussed. The papers were organized under the general topics: trace element analysis, trace analysis of organic compounds, high performance instrumentation in sample preparation, speciation analysis and posters session. Those papers of INIS interest are cited individually. (nevyjel)

  2. Determination of Aspartame and Caffeine in Carbonated Beverages Utilizing Electrospray Ionization-Mass Spectrometry

    Science.gov (United States)

    Bergen, H. Robert, III; Benson, Linda M.; Naylor, Stephen

    2000-10-01

    Mass spectrometry has undergone considerable changes in the past decade. The advent of "soft ionization" techniques such as electrospray ionization (ESI) affords the direct analysis of very polar molecules without need for the complex inefficient derivatization procedures often required in GC-MS. These ionization techniques make possible the direct mass spectral analysis of polar nonvolatile molecules such as DNA and proteins, which previously were difficult or impossible to analyze by MS. Compounds that readily take on a charge (acids and bases) lend themselves to ESI-MS analysis, whereas compounds that do not readily accept a charge (e.g. sugars) are often not seen or are seen only as inefficient adducts (e.g., M+Na+). To gain exposure to this state-of-the-art analytical procedure, high school students utilize ESI-MS in an analysis of aspartame and caffeine. They dilute a beverage sample and inject the diluted sample into the ESI-MS. The lab is procedurally simple and the results clearly demonstrate the potential and limitations of ESI-coupled mass spectrometry. Depending upon the instructional goals, the outlined procedures can be used to quantify the content of caffeine and aspartame in beverages or to understand the capabilities of electrospray ionization.

  3. Large-volume constant-concentration sampling technique coupling with surface-enhanced Raman spectroscopy for rapid on-site gas analysis

    Science.gov (United States)

    Zhang, Zhuomin; Zhan, Yisen; Huang, Yichun; Li, Gongke

    2017-08-01

    In this work, a portable large-volume constant-concentration (LVCC) sampling technique coupling with surface-enhanced Raman spectroscopy (SERS) was developed for the rapid on-site gas analysis based on suitable derivatization methods. LVCC sampling technique mainly consisted of a specially designed sampling cell including the rigid sample container and flexible sampling bag, and an absorption-derivatization module with a portable pump and a gas flowmeter. LVCC sampling technique allowed large, alterable and well-controlled sampling volume, which kept the concentration of gas target in headspace phase constant during the entire sampling process and made the sampling result more representative. Moreover, absorption and derivatization of gas target during LVCC sampling process were efficiently merged in one step using bromine-thiourea and OPA-NH4+ strategy for ethylene and SO2 respectively, which made LVCC sampling technique conveniently adapted to consequent SERS analysis. Finally, a new LVCC sampling-SERS method was developed and successfully applied for rapid analysis of trace ethylene and SO2 from fruits. It was satisfied that trace ethylene and SO2 from real fruit samples could be actually and accurately quantified by this method. The minor concentration fluctuations of ethylene and SO2 during the entire LVCC sampling process were proved to be samples were achieved in range of 95.0-101% and 97.0-104% respectively. It is expected that portable LVCC sampling technique would pave the way for rapid on-site analysis of accurate concentrations of trace gas targets from real samples by SERS.

  4. Preparation of Cu{sup 2+}/NTA-derivatized branch polyglycerol magnetic nanoparticles for protein adsorption

    Energy Technology Data Exchange (ETDEWEB)

    ShiXing Wang, E-mail: wsxkm@sina.com; Sun Wentong [Yunnan Institute of Product Quality Supervision and Inspection (China); Zhou Yang, E-mail: zhouyang8250@sohu.co [Kunming University of Science and Technology, Faculty of Metallurgical and Energy Engineering (China)

    2010-09-15

    In this report, we described the preparation of Cu{sup 2+}/nitrilotriacetic acids (NTA)-derivatized branch polyglycerol magnetic nanoparticles for protein adsorption with avoidance of nonspecific interactions at the same time. Magnetic nanoparticles (MNPs) were synthesized by the coprecipitation method. The transmission electron microscopy results showed that the average diameter of MNPs was 15.8 {+-} 4.6 nm. X-ray photoelectron spectroscopy and Fourier Transform infrared measurements indicated that branch polyglycerols were grafted on MNPs via the ring-opening polymerization of glycidol and that Cu{sup 2+} ions had been successfully immobilized on the surface of MNPs. The protein immobilization effect was characterized by UV-Vis spectrum. The results proved that Cu{sup 2+}/NTA-derivatized branch polyglycerol magnetic nanoparticles effectively adsorbed bovine haemoglobin and rarely adsorbed lysozyme and {gamma}-globin.

  5. Mass Absorption Coefficients At 661,6 keV Energy In Various Samples

    International Nuclear Information System (INIS)

    Suhariyono, Gatot; Bunawas

    2000-01-01

    Determination mass absorption coefficients (mum) at 661.6 keV energy in the samples various, such as lysine, coffee, chocolate, nutrisari, coconut oil, monosodium glutamate (MSG), tea, tin fish and the soil with experiment method has been carried out. The mum research was carried out in effort to give the measurement result of Cs-137 concentration that more accurate to the samples, because the sample density increases, mass absorption coefficients (mum) decreases. The mum correction on measurement of Cs-137 concentration in the samples various around between 0 and 13%, the highest is on the chocolate sample and the lowest is on the tin fish sample. Density of the samples decreases, the mum influence increases on the counting of Cs-137 concentration in the sample (Bq/kg)

  6. Direct analysis of samples by mass spectrometry: From elements to bio-molecules using laser ablation inductively couple plasma mass spectrometry and laser desorption/ionization mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Perdian, David C. [Iowa State Univ., Ames, IA (United States)

    2009-01-01

    Mass spectrometric methods that are able to analyze solid samples or biological materials with little or no sample preparation are invaluable to science as well as society. Fundamental research that has discovered experimental and instrumental parameters that inhibit fractionation effects that occur during the quantification of elemental species in solid samples by laser ablation inductively coupled plasma mass spectrometry is described. Research that determines the effectiveness of novel laser desorption/ionization mass spectrometric methods for the molecular analysis of biological tissues at atmospheric pressure and at high spatial resolution is also described. A spatial resolution is achieved that is able to analyze samples at the single cell level.

  7. Derivatization of castor oil based estolide esters: Preparation of epoxides and cyclic carbonates

    Science.gov (United States)

    Estolides that are based on castor oil and oleic acid are versatile starting points for the production of industrial fluids with new properties. A variety of unsaturated estolides were derivatized by epoxidation with hydrogen peroxide. The epoxidized estolides were further modified using supercritic...

  8. Accelerator mass spectrometry of small biological samples.

    Science.gov (United States)

    Salehpour, Mehran; Forsgard, Niklas; Possnert, Göran

    2008-12-01

    Accelerator mass spectrometry (AMS) is an ultra-sensitive technique for isotopic ratio measurements. In the biomedical field, AMS can be used to measure femtomolar concentrations of labeled drugs in body fluids, with direct applications in early drug development such as Microdosing. Likewise, the regenerative properties of cells which are of fundamental significance in stem-cell research can be determined with an accuracy of a few years by AMS analysis of human DNA. However, AMS nominally requires about 1 mg of carbon per sample which is not always available when dealing with specific body substances such as localized, organ-specific DNA samples. Consequently, it is of analytical interest to develop methods for the routine analysis of small samples in the range of a few tens of microg. We have used a 5 MV Pelletron tandem accelerator to study small biological samples using AMS. Different methods are presented and compared. A (12)C-carrier sample preparation method is described which is potentially more sensitive and less susceptible to contamination than the standard procedures.

  9. The analysis of aqueous mixtures using liquid chromatography-electrospray mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Steven [Iowa State Univ., Ames, IA (United States)

    1999-02-12

    The focus of this dissertation is the use of chromatographic methods coupled with electrospray mass spectrometry (ES-MS) for the determination of both organic and inorganic compounds in aqueous solutions. The combination of liquid chromatography (LC) methods and ES-MS offers one of the foremost methods for determining compounds in complex aqueous solutions. In this work, LC-ES-MS methods are devised using ion exclusion chromatography, reversed phase chromatography, and ion exchange chromatography, as well as capillary electrophoresis (CE). For an aqueous sample, these LC-ES-MS and CE-ES-MS techniques require no sample preparation or analyte derivatization, which makes it possible to observe a wide variety of analytes as they exist in solution. The majority of this work focuses on the use of LC-ES-MS for the determination of unknown products and intermediates formed during electrochemical incineration (ECI), an experimental waste remediation process. This report contains a general introduction to the project and the general conclusions. Four chapters have been removed for separate processing. Titles are: Chapter 2: Determination of small carboxylic acids by ion exclusion chromatography with electrospray mass spectrometry; Chapter 3: Electrochemical incineration of benzoquinone in aqueous media using a quaternary metal oxide electrode in the absence of a soluble supporting electrolyte; Chapter 4: The determination of electrochemical incineration products of 4-chlorophenol by liquid chromatography-electrospray mass spectrometry; and Chapter 5: Determination of small carboxylic acids by capillary electrophoresis with electrospray mass spectrometry.

  10. Sample preparations for spark source mass spectrography

    International Nuclear Information System (INIS)

    Catlett, C.W.; Rollins, M.B.; Griffin, E.B.; Dorsey, J.G.

    1977-10-01

    Methods have been developed for the preparation of various materials for spark source mass spectrography. The essential features of these preparations (all which can provide adequate precision in a cost-effective manner) consist in obtaining spark-stable electrode sample pieces, a common matrix, a reduction of anomolous effects in the spark, the incorporation of a suitable internal standard for plate response normalization, and a reduction in time

  11. Atmospheric pressure gas chromatography-time-of-flight-mass spectrometry (APGC-ToF-MS) for the determination of regulated and emerging contaminants in aqueous samples after stir bar sorptive extraction (SBSE).

    Science.gov (United States)

    Pintado-Herrera, Marina G; González-Mazo, Eduardo; Lara-Martín, Pablo A

    2014-12-03

    This work presents the development, optimization and validation of a multi-residue method for the simultaneous determination of 102 contaminants, including fragrances, UV filters, repellents, endocrine disruptors, biocides, polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and several types of pesticides in aqueous matrices. Water samples were processed using stir bar sorptive extraction (SBSE) after the optimization of several parameters: agitation time, ionic strength, presence of organic modifiers, pH, and volume of the derivatizing agent. Target compounds were extracted from the bars by liquid desorption (LD). Separation, identification and quantification of analytes were carried out by gas chromatography (GC) coupled to time-of-flight (ToF-MS) mass spectrometry. A new ionization source, atmospheric pressure gas chromatography (APGC), was tested. The optimized protocol showed acceptable recovery percentages (50-100%) and limits of detection below 1ngL(-1) for most of the compounds. Occurrence of 21 out of 102 analytes was confirmed in several environmental aquatic matrices, including seawater, sewage effluent, river water and groundwater. Non-target compounds such as organophosphorus flame retardants were also identified in real samples by accurate mass measurement of their molecular ions using GC-APGC-ToF-MS. To the best of our knowledge, this is the first time that this technique has been applied for the analysis of contaminants in aquatic systems. By employing lower energy than the more widely used electron impact ionization (EI), AGPC provides significant advantages over EI for those substances very susceptible to high fragmentation (e.g., fragrances, pyrethroids). Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Determination of amphetamine-type stimulants in oral fluid by solid-phase microextraction and gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Souza, Daniele Z.; Boehl, Paula O.; Comiran, Eloisa; Mariotti, Kristiane C.; Pechansky, Flavio; Duarte, Paulina C.A.V.; De Boni, Raquel; Froehlich, Pedro E.; Limberger, Renata P.

    2011-01-01

    Graphical abstract: Highlights: → Propylchloroformate derivatization of amphetamine-type stimulants in oral fluid. → Direct immersion solid-phase microextraction/gas chromatography-mass spectrometry. → Linear range 2(4)-256 ng mL -1 , detection limits 0.5-2 ng mL -1 . → Accuracy 98-112%, precision TM device has been developed and validated. Thereunto, in-matrix propylchloroformate derivatization followed by direct immersion solid-phase microextraction and gas chromatography-mass spectrometry were employed. Deuterium labeled AMP was used as internal standard for all the stimulants and analysis was performed using the selected ion monitoring mode. The detector response was linear for the studied drugs in the concentration range of 2-256 ng mL -1 (neat oral fluid), except for FEN, whereas the linear range was 4-256 ng mL -1 . The detection limits were 0.5 ng mL -1 (MET), 1 ng mL -1 (MPH) and 2 ng mL -1 (DIE, AMP, FEN), respectively. Accuracy of quality control samples remained within 98.2-111.9% of the target concentrations, while precision has not exceeded 15% of the relative standard deviation. Recoveries with Quantisal TM device ranged from 77.2% to 112.1%. Also, the goodness-of-fit concerning the ordinary least squares model in the statistical inference of data has been tested through residual plotting and ANOVA. The validated method can be easily automated and then used for screening and confirmation of amphetamine-type stimulants in drivers' oral fluid.

  13. Optimal sample to tracer ratio for isotope dilution mass spectrometry: the polyisotopic case

    International Nuclear Information System (INIS)

    Laszlo, G.; Ridder, P. de; Goldman, A.; Cappis, J.; Bievre, P. de

    1991-01-01

    The Isotope Dilution Mass Spectrometry (IDMS) measurement technique provides a means for determining the unknown amount of various isotopes of an element in a sample solution of known mass. The sample solution is mixed with an auxiliary solution, or tracer, containing a known amount of the same element having the same isotopes but of different relative abundances or isotopic composition and the induced change in the isotopic composition measured by isotope mass spectrometry. The technique involves the measurement of the abundance ratio of each isotope to a (same) reference isotope in the sample solution, in the tracer solution and in the blend of the sample and tracer solution. These isotope ratio measurements, the known element amount in the tracer and the known mass of sample solution are used to calculate the unknown amount of one isotope in the sample solution. Subsequently the unknown amount of element is determined. The purpose of this paper is to examine the optimization of the ratio of the estimated unknown amount of element in the sample solution to the known amount of element in the tracer solution in order to minimize the relative uncertainty in the determination of the unknown amount of element

  14. Measurement of 12(S)-hydroxy-5Z,8E,10E-heptadecatrienoic acid and its metabolite 12-oxo-5Z,8E,10E-heptadecatrienoic acid in human plasma by gas chromatography/negative ion chemical ionization mass spectrometry

    International Nuclear Information System (INIS)

    Hofmann, U.; Seefried, S.; Meese, C.O.; Mettang, T.; Huebel, E.K.; Kuhlmann, U.

    1990-01-01

    Thromboxane A2, the predominant product of arachidonic acid metabolism in the blood platelet, is a potent vasoconstrictor and platelet agonist. During its biosynthesis from cyclic endoperoxide, 12(S)-hydroxy-5Z,8E,10E-heptadecatrienoic acid (HHT) is formed in equal amounts. The further metabolism of HHT, catalyzed by 15-hydroxyprostaglandin dehydrogenase, leads to 12-oxo-5Z,8E,10E-heptadecatrienoic acid (Oxo-HT). Sample workup procedures are described which allow for the sensitive and reproducible determination of these two arachidonic acid metabolites in human plasma by gas chromatography-mass spectrometry in the presence of deuterated analogues as internal standards. HHT is derivatized to the pentafluorobenzyl ester tert-butyldimethylsilyl ether. In order to enable quantification of low concentrations of about 10 pg/ml in nonstimulated human plasma, the samples have to be purified by HPLC. Oxo-HT is derivatized to the pentafluorobenzyl ester, which is purified by HPLC, and then derivatized to the trimethylsilyloxime. The method allows quantification of Oxo-HT in concentrations down to 10 pg/ml plasma. The reported methods have been used to measure HHT and Oxo-HT in stimulated platelet rich plasma and to quantify HHT in nonstimulated plasma. Determination of endogenous levels of these two arachidonic acid metabolites may give new insights into the overall biosynthesis of thromboxane A2 in man

  15. Helium-3 mass spectrometry for low-level tritium analysis of environmental samples

    International Nuclear Information System (INIS)

    Surano, K.A.; Hudson, G.B.; Failor, R.A.; Sims, J.M.; Holland, R.C.; MacLean, S.C.; Garrison, J.C.

    1991-04-01

    Helium-3 ( 3 He) mass spectrometry for the analysis of low-level tritium ( 3 H) concentrations in environmental sample matrices was compared with conventional low-level β-decay counting methods. The mass-spectrometry method compared favorably, equaling or surpassing conventional decay-counting methods with respect to most criteria. Additional research and method refinements may make 3 He mass spectrometry the method of choice for routine, low-level to very-low-level 3 H measurements in a wide variety of environmental samples in the future

  16. Quantitation of 25-hydroxyvitamin D in dried blood spots by 2D LC-MS/MS without derivatization and correlation with serum in adult and pediatric studies.

    Science.gov (United States)

    Jensen, Berit P; Saraf, Rajneeta; Ma, Jing; Berry, Sarah; Grant, Cameron C; Camargo, Carlos A; Sies, Christiaan W

    2018-06-01

    Demand for measurement of 25-hydroxyvitamin D (25OHD) is growing and dried blood spot (DBS) sampling is attractive as samples are easier to collect, transport and store. A 2D LC-MS/MS assay without derivatization was developed. DBS punches (3.2 mm) were ultrasonicated with d 6 -25OHD 3 in 70% methanol followed by hexane extraction, dry-down and reconstitution. The assay was validated and applied to two studies comparing whole blood adult DBS with serum samples (n = 40) and neonatal whole blood DBS with cord serum samples (n = 80). The assay was validated in whole blood DBS over the range 13-106 nmol/L 25OHD 3 and 11-91 nmol/L 25OHD 2 with a limit of detection of 3 nmol/L. Intra- and inter-day imprecision was <13% CV and bias <12%. The assay had high recovery and minimal matrix effects. Triplicate DBS study samples had a mean CV of ≤13% for 25OHD 3. No 25OHD 2 was detected. DBS calculated serum 25OHD 3 concentrations correlated strongly with serum concentrations in the adult DBS/serum study (r = 0.94) and moderately in the neonatal DBS/cord serum study (r = 0.69). Direct quantitation of 25OHD in DBS by 2D LC-MS/MS without derivatization was found to be an alternative to serum quantitation applicable to clinical research studies on adult DBS samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Determination of steroid hormones and related compounds in filtered and unfiltered water by solid-phase extraction, derivatization, and gas chromatography with tandem mass spectrometry

    Science.gov (United States)

    Foreman, William T.; Gray, James L.; ReVello, Rhiannon C.; Lindley, Chris E.; Losche, Scott A.; Barber, Larry B.

    2012-01-01

    activated -methyl--trimethylsilyl trifluoroacetamide at 65 degrees Celsius for 1 hour to form trimethylsilyl or trimethylsilyl-enol ether derivatives that are more amenable to gas chromatographic separation than the underivatized compounds. Analysis is carried out by gas chromatography with tandem mass spectrometry using calibration standards that are derivatized concurrently with the sample extracts. Analyte concentrations are quantified relative to specific IDS compounds in the sample, which directly compensate for procedural losses (incomplete recovery) in the determined and reported analyte concentrations. Thus, reported analyte concentrations (or analyte recoveries for spiked samples) are corrected based on recovery of the corresponding IDS compound during the quantification process. Recovery for each IDS compound is reported for each sample and represents an absolute recovery in a manner comparable to surrogate recoveries for other organic methods used by the National Water Quality Laboratory. Thus, IDS recoveries provide a useful tool for evaluating sample-specific analytical performance from an absolute mass recovery standpoint. IDS absolute recovery will differ and typically be lower than the corresponding analyte’s method recovery in spiked samples. However, additional correction of reported analyte concentrations is unnecessary and inappropriate because the analyte concentration (or recovery) already is compensated for by the isotope-dilution quantification procedure. Method analytes were spiked at 10 and 100 nanograms per liter (ng/L) for most analytes (10 times greater spike levels were used for bisphenol A and 100 times greater spike levels were used for 3--coprostanol and cholesterol) into the following validation-sample matrices: reagent water, wastewater-affected surface water, a secondary-treated wastewater effluent, and a primary (no biological treatment) wastewater effluent. Overall method recovery for all analytes in these matrices averaged 100

  18. Gas Chromatographic Mass Spectrometric Determination of Myo-inositol in Humans Utilizing a Deuterated Internal Standard

    DEFF Research Database (Denmark)

    Andersen, Jan Rud; Larsen, Elfinn; Harbo, Helge

    1982-01-01

    The isotopic dilution technique was used for determining the content of myo-inositol in human urine, plasma and haemolysed erythrocyte samples. A deuterated myo-inositol, synthesized from inosose-2 by base-catalysed exchange of hydrogens by deuterium, followed by reduction of the inosose with 2H2......, was added as internal standard to the samples at an early stage in the analytical procedure. After separation and derivatization to the hexa-acetate, the gas chromatographic mass spectrometric analysis was carried out. A 25 m fused silica capillary column coated with methyl silicone was used, and the ions...... selected for monitoring were m/z 210 and m/z 214, which are characteristic and abundant fragment ions from unlabelled and hexadeuterated myo-inositolhexa-acetate, respectively. Calibration curves from water, urine, plasma and haemolysed erythrocytes show parallel, linear responses in the ratio between...

  19. [Mass spectrometry technology and its application in analysis of biological samples].

    Science.gov (United States)

    Zhao, Long-Shan; Li, Qing; Guo, Chao-Wei; Chen, Xiao-Hui; Bi, Kai-Shun

    2012-02-01

    With the excellent merits of wide analytical range, high sensitivity, small sample size, fast analysis speed, good repeatability, simple operation, low mobile phase consumption, as well as its capability of simultaneous isolation and identification, etc, mass spectrometry techniques have become widely used in the area of environmental science, energy chemical industry, biological medicine, and so on. This article reviews the application of mass spectrometry technology in biological sample analysis in the latest three years with the focus on the new applications in pharmacokinetics and bioequivalence, toxicokinetics, pharmacokinetic-pharmacodynamic, population pharmacokinetics, identification and fragmentation pathways of drugs and their metabolites and metabonomics to provide references for further study of biological sample analysis.

  20. Analysis of non-esterified fatty acids in human samples by solid-phase-extraction and gas chromatography/mass spectrometry.

    Science.gov (United States)

    Kopf, Thomas; Schmitz, Gerd

    2013-11-01

    The determination of the fatty acid (FA) profile of lipid classes is essential for lipidomic analysis. We recently developed a GC/MS-method for the analysis of the FA profile of total FAs, i.e. the totality of bound and unbound FAs, in any given biological sample (TOFAs). Here, we present a method for the analysis of non-esterified fatty acids (NEFAs) in biological samples, i.e. the fraction that is present as extractable free fatty acids. Lipid extraction is performed according to Dole using 80/20 2-propanol/n-hexane (v/v), with 0.1% H2SO4. The fatty acid-species composition of this NEFA-fraction is determined as FAME after derivatization with our GC/MS-method on a BPX column (Shimadzu). Validation of the NEFA-method presented was performed in human plasma samples. The validated method has been used with human plasma, cells and tissues, as well as mammalian body fluids and tissue samples. The newly developed solid-phase-extraction (SPE)-GC-MS method allows the rapid separation of the NEFA-fraction from a neutral lipid extract of plasma samples. As a major advantage compared to G-FID-methods, GC-MS allows the use of stable isotope labeled fatty acid precursors to monitor fatty acid metabolism. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Thiol derivatization of Xanthan gum and its evaluation as a mucoadhesive polymer.

    Science.gov (United States)

    Bhatia, Meenakshi; Ahuja, Munish; Mehta, Heena

    2015-10-20

    Thiol-derivatization of xanthan gum polysaccharide was carried out by esterification with mercaptopropionic acid and thioglycolic acid. Thiol-derivatization was confirmed by Fourier-transformed infra-red spectroscopy. Xanthan-mercaptopropionic acid conjugate and xanthan-thioglycolic acid conjugate were found to possess 432.68mM and 465.02mM of thiol groups as determined by Ellman's method respectively. Comparative evaluation of mucoadhesive property of metronidazole loaded buccal pellets of xanthan and thiolated xanthan gum using chicken buccal pouch membrane revealed higher ex vivo bioadhesion time of thiolated xanthan gum as compared to xanthan gum. Improved mucoadhesive property of thiolated xanthan gum over the xanthan gum can be attributed to the formation of disulfide bond between mucus and thiolated xanthan gum. In vitro release study conducted using phosphate buffer (pH 6.8) revealed a sustained release profile of metronidazole from thiolated xanthan pellets as compared to xanthan pellets. In conclusion, thiolation of xanthan improves its mucoadhesive property and sustained the release of metronidazole over a prolonged period. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Targeted selected reaction monitoring mass spectrometric immunoassay for insulin-like growth factor 1.

    Directory of Open Access Journals (Sweden)

    Eric E Niederkofler

    Full Text Available Insulin-like growth factor 1 (IGF1 is an important biomarker of human growth disorders that is routinely analyzed in clinical laboratories. Mass spectrometry-based workflows offer a viable alternative to standard IGF1 immunoassays, which utilize various pre-analytical preparation strategies. In this work we developed an assay that incorporates a novel sample preparation method for dissociating IGF1 from its binding proteins. The workflow also includes an immunoaffinity step using antibody-derivatized pipette tips, followed by elution, trypsin digestion, and LC-MS/MS separation and detection of the signature peptides in a selected reaction monitoring (SRM mode. The resulting quantitative mass spectrometric immunoassay (MSIA exhibited good linearity in the range of 1 to 1,500 ng/mL IGF1, intra- and inter-assay precision with CVs of less than 10%, and lowest limits of detection of 1 ng/mL. The linearity and recovery characteristics of the assay were also established, and the new method compared to a commercially available immunoassay using a large cohort of human serum samples. The IGF1 SRM MSIA is well suited for use in clinical laboratories.

  3. Multidimensional chromatography coupled to mass spectrometry in analysing complex proteomics samples

    NARCIS (Netherlands)

    Horvatovich, Peter; Hoekman, Berend; Govorukhina, Natalia; Bischoff, Rainer

    Multidimensional chromatography coupled to mass spectrometry (LC(n)-MS) provides more separation power and an extended measured dynamic concentration range to analyse complex proteomics samples than one dimensional liquid chromatography coupled to mass spectrometry (1D-LC-MS). This review gives an

  4. Solid Sampling with a Diode Laser for Portable Ambient Mass Spectrometry.

    Science.gov (United States)

    Yung, Yeni P; Wickramasinghe, Raveendra; Vaikkinen, Anu; Kauppila, Tiina J; Veryovkin, Igor V; Hanley, Luke

    2017-07-18

    A hand-held diode laser is implemented for solid sampling in portable ambient mass spectrometry (MS). Specifically, a pseudocontinuous wave battery-powered surgical laser diode is employed for portable laser diode thermal desorption (LDTD) at 940 nm and compared with nanosecond pulsed laser ablation at 2940 nm. Postionization is achieved in both cases using atmospheric pressure photoionization (APPI). The laser ablation atmospheric pressure photoionization (LAAPPI) and LDTD-APPI mass spectra of sage leaves (Salvia officinalis) using a field-deployable quadrupole ion trap MS display many similar ion peaks, as do the mass spectra of membrane grown biofilms of Pseudomonas aeruginosa. These results indicate that LDTD-APPI method should be useful for in-field sampling of plant and microbial communities, for example, by portable ambient MS. The feasibility of many portable MS applications is facilitated by the availability of relatively low cost, portable, battery-powered diode lasers. LDTD could also be coupled with plasma- or electrospray-based ionization for the analysis of a variety of solid samples.

  5. Sample Preparation for Mass Spectrometry Imaging of Plant Tissues: A Review

    Science.gov (United States)

    Dong, Yonghui; Li, Bin; Malitsky, Sergey; Rogachev, Ilana; Aharoni, Asaph; Kaftan, Filip; Svatoš, Aleš; Franceschi, Pietro

    2016-01-01

    Mass spectrometry imaging (MSI) is a mass spectrometry based molecular ion imaging technique. It provides the means for ascertaining the spatial distribution of a large variety of analytes directly on tissue sample surfaces without any labeling or staining agents. These advantages make it an attractive molecular histology tool in medical, pharmaceutical, and biological research. Likewise, MSI has started gaining popularity in plant sciences; yet, information regarding sample preparation methods for plant tissues is still limited. Sample preparation is a crucial step that is directly associated with the quality and authenticity of the imaging results, it therefore demands in-depth studies based on the characteristics of plant samples. In this review, a sample preparation pipeline is discussed in detail and illustrated through selected practical examples. In particular, special concerns regarding sample preparation for plant imaging are critically evaluated. Finally, the applications of MSI techniques in plants are reviewed according to different classes of plant metabolites. PMID:26904042

  6. Sample Preparation for Mass Spectrometry Imaging of Plant Tissues: A Review.

    Science.gov (United States)

    Dong, Yonghui; Li, Bin; Malitsky, Sergey; Rogachev, Ilana; Aharoni, Asaph; Kaftan, Filip; Svatoš, Aleš; Franceschi, Pietro

    2016-01-01

    Mass spectrometry imaging (MSI) is a mass spectrometry based molecular ion imaging technique. It provides the means for ascertaining the spatial distribution of a large variety of analytes directly on tissue sample surfaces without any labeling or staining agents. These advantages make it an attractive molecular histology tool in medical, pharmaceutical, and biological research. Likewise, MSI has started gaining popularity in plant sciences; yet, information regarding sample preparation methods for plant tissues is still limited. Sample preparation is a crucial step that is directly associated with the quality and authenticity of the imaging results, it therefore demands in-depth studies based on the characteristics of plant samples. In this review, a sample preparation pipeline is discussed in detail and illustrated through selected practical examples. In particular, special concerns regarding sample preparation for plant imaging are critically evaluated. Finally, the applications of MSI techniques in plants are reviewed according to different classes of plant metabolites.

  7. Design, Synthesis, and Characterization of Novel Thiol-Derivatized Ibuprofen Monolayer Protected Gold Clusters

    International Nuclear Information System (INIS)

    Lee, K.H.; Lee, K.H.; Lin, Y.Sh.; Huang, P.J.

    2013-01-01

    A series of new thiol-derivatized ibuprofen monolayer protected gold clusters have been prepared by amidation of ibuprofen with alkyl alcohol or aminophenol affording the carboxamide, N-hydroxyalkyl amide 2, and N-hydroxyphenyl amide 6, which were then tosylate with p-toluenesulfonyl chloride at hydroxyl group to give 3 and 7. Reactions of 3 and 7 with NaSH afforded the mercapto derivatives 4 and 8. Conducting Brust’s reaction with a 3:1 mole ratio of thiolate ibuprofen/ AuCl 4 - yielded polydisperse thiol-derivatized ibuprofen-MPCs 5 and 9. All compounds have been identified by NMR, MS, UV, and IR spectroscopies. Compounds 4 and 8 and the MPCs 5 and 9 have been investigated by using the method of 1 H NMR spectroscopy. The broadening of the signals from 0.8 to 2.0 ppm in 1 H NMR spectrum of MPCs 5 and 9 confirmed the success of the conjugation of thiol-containing derivatives with nano gold cluster.

  8. Quantification of carbonate by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Tsikas, Dimitrios; Chobanyan-Jürgens, Kristine

    2010-10-01

    Carbon dioxide and carbonates are widely distributed in nature, are constituents of inorganic and organic matter, and are essential in vegetable and animal organisms. CO(2) is the principal greenhouse gas in the atmosphere. In human blood, CO(2)/HCO(3)(-) is an important buffering system. Quantification of bicarbonate and carbonate in inorganic and organic matter and in biological fluids such as blood or blood plasma by means of the GC-MS technology has been impossible so far, presumably because of the lack of suitable derivatization reactions to produce volatile and thermally stable derivatives. Here, a novel derivatization reaction is described for carbonate that allows for its quantification in aqueous alkaline solutions and alkalinized plasma and urine. Carbonate in acetonic solutions of these matrices (1:4 v/v) and added (13)C-labeled carbonate for use as the internal standard were heated in the presence of the derivatization agent pentafluorobenzyl (PFB) bromide for 60 min and 50 °C. Investigations with (12)CO(3)(2-), (13)CO(3)(2-), (CH(3))(2)CO, and (CD(3))(2)CO in alkaline solutions and GC-MS and GC-MS/MS analyses under negative-ion chemical ionization (NICI) or electron ionization (EI) conditions of toluene extracts of the reactants revealed formation of two minor [i.e., PFB-OCOOH and O=CO(2)-(PFB)(2)] and two major [i.e., CH(3)COCH(2)-C(OH)(OPFB)(2) and CH(3)COCH=C(OPFB)(2)] carbonate derivatives. The latter have different retention times (7.9 and 7.5 min, respectively) but virtually identical EI and NICI mass spectra. It is assumed that CH(3)COCH(2)-C(OH)(OPFB)(2) is formed from the reaction of the carbonate dianion with two molecules of PFB bromide to form the diPFB ester of carbonic acid, which further reacts with one molecule of acetone. Subsequent loss of water finally generates the major derivative CH(3)COCH=C(OPFB)(2). This derivatization reaction was utilized to quantify total CO(2)/HCO(3)(-)/CO(3)(2-) (tCO(2)) in human plasma and urine by GC

  9. Microwave-assisted decomplexation and in-situ headspace in-syringe dynamic derivatization of dimethylamine borane with high performance liquid chromatography-fluorescence detection.

    Science.gov (United States)

    Muniraj, Sarangapani; Lee, Hua-Kwang; Hsiech, Chunming; Jen, Jen-Fon

    2018-02-16

    A rapid, sensitive, selective, and simple method for monitoring dimethylamine borane (DMAB) in aqueous sample is proposed by combining microwave-assisted de-complexation, headspace liquid phase in-situ derivatization extraction, and high-performance liquid chromatography-fluorescence detection for the determination of DMAB in samples. The present procedure involves de-complexation of DMAB using microwave irradiation, evolution of dimethylamine (DMA) to the headspace from an alkalized sample solution, and dynamic headspace liquid-phase derivatization extraction (Dy-HS-LPDE) of DMA with 9-fluorenylmethyl chloroformate in a syringe barrel. In addition to the optimal Dy-HS-LPDE and chromatographic parameters described in our previous study, the de-complexation of DMAB by thermal and microwave-assisted procedures and evolution of DMA into the headspace from an alkalized solution and modification of the Dy-HS-LPDE method are thoroughly investigated. The results indicate that complete de-complexation was obtained at 70 °C for 5 min, 30 °C for 10 min, or using microwave irradiation for 30 s at any applied power. It indicates that the DMAB complex easily undergoes de-complexation under microwave irradiation. The linearity range was 0.01-0.5 mg L -1 for DMAB and 0.0077-0.38 mg L -1 for DMA, with a coefficient of determination of 0.9995, and limit of detection of 3 μg L -1 (limit of quantitation of 10 μg L -1 ) for DMAB. The recoveries of DMAB are 95.3% (3.0% RSD) for waste water when spiked 0.05 mg L -1 and 93.5% (5.4% RSD) for the samples spiked with copper and nickel salts (5 mM each in the spiked waste sample). The whole analytical procedure can be completed within 25 min. The results confirm that the present method is a rapid, sensitive, selective, automated, low-cost and eco-friendly procedure to identify DMAB in samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Determination of Nonvolatile Amines in Foods by Improved Dansyl Derivatization Reaction.

    Science.gov (United States)

    Handa, Ayami; Kawanabe, Hitomi; Ibe, Akihiro

    2017-01-01

    An analytical method for the determination of nonvolatile amines (putrescine, cadaverine, histamine, tyramine, and spermidine) in foods was developed, using an improved dansyl derivatization technique. The five amines were extracted from food with 1% trichloroacetic acid. Three milliliter of extract was applied to a polymer-based strong cation exchange resin mini-column, which was washed with 5 mL of water, and eluted with 5 mL of 1 mol/L potassium carbonate solution. The eluate was dansylated, then 5 mL of toluene was added with shaking. The toluene layer was evaporated. The residue was taken up in 1 mL of acetonitrile and shaken with 1 mL of 5% proline in 1 mol/L potassium carbonate solution. The upper acetonitrile layer was collected, filtered, and subjected to HPLC. The limits of quantitation for putrescine and cadaverine in the samples were both 0.2 μg/g; those of spermidine, tyramine, and histamine were 0.8, 2.0, and 5.0 μg/g, respectively. The average recoveries of the five amines from nine foods exceeded 80%.

  11. Characterization of Jamaican agro-industrial wastes. Part II, fatty acid profiling using HPLC: precolumn derivatization with phenacyl bromide.

    Science.gov (United States)

    Bailey-Shaw, Y A; Golden, K D; Pearson, A G M; Porter, R B R

    2012-09-01

    This paper describes the determination of fatty acid composition of coffee, citrus and rum distillery wastes using reversed-phase high-performance liquid chromatography (RP-HPLC). Lipid extracts of the waste samples are derivatized with phenacyl bromide and their phenacyl esters are separated on a C8 reversed-phase column by using continuous gradient elution with water and acetonitrile. The presence of saturated and unsaturated fatty acids in quantifiable amounts in the examined wastes, as well as the high percentage recoveries, are clear indications that these wastes have potential value as inexpensive sources of lipids. The HPLC procedures described here could be adopted for further analysis of materials of this nature.

  12. Chiral Analysis of Methamphetamine in Oral Fluid Samples: A Method to Distinguish Licit from Illicit Drug Use.

    Science.gov (United States)

    Borg, Damon; Kolb, Elizabeth; Lantigua, Cindy; Stripp, Richard

    2018-01-01

    Methamphetamine (MAMP) is a popular illicit drug abused for its central nervous system stimulating effects. MAMP is also used therapeutically in the treatment of overeating disorders, narcolepsy, attention deficit disorder, in over-the-counter (OTC) products to ease nasal congestion. MAMP exists in two enantiomeric forms, dextrorotary (d-MAMP) or levorotary (l-MAMP). The compounds are similar in chemical structure, simply differing in the orientation of functional groups around the asymmetric carbon. In part because of the availability of l-MAMP in OTC nasal inhalers, forensic guidelines require a sample to contain greater than 20% d-MAMP to consider illicit drug use when interpreting results. Standard analytical methods readily detect MAMP in biological specimens but cannot resolve the enantiomeric composition of the sample. Specialized analytical techniques based on chiral separation of the enantiomers are required to differentiate d-MAMP from l-MAMP. Our laboratory sought to develop and validate a method for the analysis of oral fluid specimens for d/l-MAMP using a chiral derivatizing agent and traditional reverse phase liquid chromatography tandem mass spectrometry (LC-MS-MS). MAMP was extracted from dilute oral fluid samples using Strata-XC solid phase extraction (SPE) cartridges and derivatized with Marfey's reagent. Chromatographic separation was achieved using Zorbax Eclipse Plus C18 columns. Linearity, accuracy and precision, recovery, matrix effects and specificity of the method were all within acceptable criteria. Intraday accuracy ranged from 93.3 to 103.4% and precision 0.1 to 1.6%. Interday accuracy ranged from 90.0 to 103.4% and precision 3.8 to 11.6%. Finally, having previously tested positive for MAMP using non-chiral analysis, 256 de-identified authentic oral fluid samples were analyzed using this validated method. 98% of all samples tested positive for d-MAMP at greater than 20%.

  13. High molecular weight non-polar hydrocarbons as pure model substances and in motor oil samples can be ionized without fragmentation by atmospheric pressure chemical ionization mass spectrometry.

    Science.gov (United States)

    Hourani, Nadim; Kuhnert, Nikolai

    2012-10-15

    High molecular weight non-polar hydrocarbons are still difficult to detect by mass spectrometry. Although several studies have targeted this problem, lack of good self-ionization has limited the ability of mass spectrometry to examine these hydrocarbons. Failure to control ion generation in the atmospheric pressure chemical ionization (APCI) source hampers the detection of intact stable gas-phase ions of non-polar hydrocarbon in mass spectrometry. Seventeen non-volatile non-polar hydrocarbons, reported to be difficult to ionize, were examined by an optimized APCI methodology using nitrogen as the reagent gas. All these analytes were successfully ionized as abundant and intact stable [M-H](+) ions without the use of any derivatization or adduct chemistry and without significant fragmentation. Application of the method to real-life hydrocarbon mixtures like light shredder waste and car motor oil was demonstrated. Despite numerous reports to the contrary, it is possible to ionize high molecular weight non-polar hydrocarbons by APCI, omitting the use of additives. This finding represents a significant step towards extending the applicability of mass spectrometry to non-polar hydrocarbon analyses in crude oil, petrochemical products, waste or food. Copyright © 2012 John Wiley & Sons, Ltd.

  14. A new derivatization method for δ18O analysis of individual carbohydrates with GC-Pyrolysis-IRMS

    Science.gov (United States)

    Lehmann, M. M.; Siegwolf, R. T.; Saurer, M.; Blees, J.; Fischer, M.; Zech, M.

    2015-12-01

    Compound specific isotope analysis (CSIA) with gas chromatography coupled to an isotope ratio mass spectrometer (GC-Pyr-IRMS) is nowadays a powerful tool that is widely used by a broad spectrum of research fields to investigate the isotopic signature of diverse metabolites. While many CSIA methods for carbon, hydrogen, and nitrogen isotopes are known, CSIA methods for the analysis of oxygen isotopes (δ18O) are still not widely established. Especially, reliable and precise methods for the δ18O analyses of individual carbohydrates are scarce, which is caused by the highly sensitive nature of the sugars. However, carbohydrates are important components of living organisms, source for many biochemical reactions, and can be found in all organisms, in soils, sediments, and in air. Thus, a method, allowing the investigation of the 18O/16O ratio in carbohydrates will enhance the scope of research using isotopes. We developed a new and easy to handle derivatization method to determine δ18O in carbohydrates with GC-Pyr-IRMS that consists of a catalyzed one-pot reaction in acetonitrile, resulting in complete methylation of all sugar hydroxyl groups within 24 hours, with silver oxide as the proton acceptor and methyl iodide as the methyl group carrier. Results derived from standard material show unrivalled δ18O precision ranging from about 0.2 to 1.1 ‰ for different individual carbohydrates of different classes and a generally very good accuracy, with a narrow range of 0.2 ‰ around the reference value, despite of high area variations. We applied this method on real samples, demonstrating that the method can commonly be used for analyzing honey samples, and for the analyses of more complex carbohydrate mixtures from plant leaves, including glucose, fructose, pinitol, and sucrose. Our new method may be used for food, beverage, and medical applications, as well as for biogeochemical and paleoclimatic sciences.

  15. Enhancement of sensitivity in the determination of organic trace compounds in complex matrices with liquid chromatography-mass spectrometry (LC-MS)

    International Nuclear Information System (INIS)

    Mascher, D.G.

    2002-05-01

    The PhD-thesis deals with 'enhancement of sensitivity in the determination of organic trace compounds in complex matrices with liquid chromatography-mass spectrometry (LC-MS)'. Almost the most important factor is the enhancement of the ionization yield with Atmospheric Pressure Chemical Ionization (APCI) or Electrospray Ionization (ESI) in LC-MS. Ionization yields of different compounds can vary by a factor of 10000. Three ways to solve this problem of little ionization yield were tried: 1) Modification of the mobile phase in HPLC 2) Chemical modification of the analytes 3) A new type of ionization called Atmospheric Pressure Photo Ionization (APPI). ad 1) By using specific additives to mobile phases ion suppression that might derive from an ion pair reagent that was necessary for chromatography could be omitted. General remarks cannot be done. ad 2) Chemical modification or so called derivatization is well known for UV- and fluorescence-detection for a long period of time. As substances containing nitrogene (e.g. primary, secondary or tertiary amines) often have good ionization yields, poor or relatively poor ionizable substances like carboxylic acids, sugars and partially phenolic steroids were used as analytes for derivatization reactions. By using Dansyl as Dansylchlorid or Dansylhydrazine a basic derivatization agent could be found that ionizes very well. A 200 times more sensitive determination of estrogenes is possible after derivatization with Dansylchlorid. Using a tandem-mass-spectrometer a lower limit of quantification of 2 pg/mL plasma could be reached by using 1 mL of plasma. For ketones like carvon and campher an enhancement by a factor of 500 and 4000 could be reached by using Dansylhydrazine as the derivatization agent. For fatty acids DMEQ as derivatization agent enhanced the sensitivity by a factor of 20 to 100. ad 3) APPI as a new ionization mode showed really good results for specific molecules. Relatively unpolar substances as diphenylsulfide

  16. Radionuclide determination in environmental samples by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Lariviere, Dominic; Taylor, Vivien F.; Evans, R. Douglas; Cornett, R. Jack

    2006-01-01

    The determination of naturally occurring and anthropogenic radionuclides in the environment by inductively coupled plasma mass spectrometry has gained recognition over the last fifteen years, relative to radiometric techniques, as the result of improvement in instrumental performance, sample introduction equipment, and sample preparation. With the increase in instrumental sensitivity, it is now possible to measure ultratrace levels (fg range) of many radioisotopes, including those with half-lives between 1 and 1000 years, without requiring very complex sample pre-concentration schemes. However, the identification and quantification of radioisotopes in environmental matrices is still hampered by a variety of analytical issues such as spectral (both atomic and molecular ions) and non-spectral (matrix effect) interferences and instrumental limitations (e.g., abundance sensitivity). The scope of this review is to highlight recent analytical progress and issues associated with the determination of radionuclides by inductively coupled plasma mass spectrometry. The impact of interferences, instrumental limitations (e.g., degree of ionization, abundance sensitivity, detection limits) and low sample-to-plasma transfer efficiency on the measurement of radionuclides by inductively coupled plasma mass spectrometry will be described. Solutions that overcome these issues will be discussed, highlighting their pros and cons and assessing their impact on the measurement of environmental radioactivity. Among the solutions proposed, mass and chemical resolution through the use of sector-field instruments and chemical reactions/collisions in a pressurized cell, respectively, will be described. Other methods, such as unique sample introduction equipment (e.g., laser ablation, electrothermal vaporisation, high efficiency nebulization) and instrumental modifications/optimizations (e.g., instrumental vacuum, radiofrequency power, guard electrode) that improve sensitivity and performance

  17. Dual Source Time-of-flight Mass Spectrometer and Sample Handling System

    Science.gov (United States)

    Brinckerhoff, W.; Mahaffy, P.; Cornish, T.; Cheng, A.; Gorevan, S.; Niemann, H.; Harpold, D.; Rafeek, S.; Yucht, D.

    We present details of an instrument under development for potential NASA missions to planets and small bodies. The instrument comprises a dual ionization source (laser and electron impact) time-of-flight mass spectrometer (TOF-MS) and a carousel sam- ple handling system for in situ analysis of solid materials acquired by, e.g., a coring drill. This DSTOF instrument could be deployed on a fixed lander or a rover, and has an open design that would accommodate measurements by additional instruments. The sample handling system (SHS) is based on a multi-well carousel, originally de- signed for Champollion/DS4. Solid samples, in the form of drill cores or as loose chips or fines, are inserted through an access port, sealed in vacuum, and transported around the carousel to a pyrolysis cell and/or directly to the TOF-MS inlet. Samples at the TOF-MS inlet are xy-addressable for laser or optical microprobe. Cups may be ejected from their holders for analyzing multiple samples or caching them for return. Samples are analyzed with laser desorption and evolved-gas/electron-impact sources. The dual ion source permits studies of elemental, isotopic, and molecular composition of unprepared samples with a single mass spectrometer. Pulsed laser desorption per- mits the measurement of abundance and isotope ratios of refractory elements, as well as the detection of high-mass organic molecules in solid samples. Evolved gas analysis permits similar measurements of the more volatile species in solids and aerosols. The TOF-MS is based on previous miniature prototypes at JHU/APL that feature high sensitivity and a wide mass range. The laser mode, in which the sample cup is directly below the TOF-MS inlet, permits both ablation and desorption measurements, to cover elemental and molecular species, respectively. In the evolved gas mode, sample cups are raised into a small pyrolysis cell and heated, producing a neutral gas that is elec- tron ionized and pulsed into the TOF-MS. (Any imaging

  18. A rapid hydrolysis method and DABS-Cl derivatization for complete amino acid analysis of octreotide acetate by reversed phase HPLC.

    Science.gov (United States)

    Akhlaghi, Yousef; Ghaffari, Solmaz; Attar, Hossein; Alamir Hoor, Amir

    2015-11-01

    Octreotide as a synthetic cyclic octapeptide is a somatostatin analog with longer half-life and more selectivity for inhibition of the growth hormone. The acetate salt of octreotide is currently used for medical treatment of somatostatin-related disorders such as endocrine and carcinoid tumors, acromegaly, and gigantism. Octreotide contains both cysteine and tryptophan residues which make the hydrolysis part of its amino acid analysis procedure very challenging. The current paper introduces a fast and additive-free method which preserves tryptophan and cysteine residues during the hydrolysis. Using only 6 M HCl, this hydrolysis process is completed in 30 min at 150 °C. This fast hydrolysis method followed by pre-column derivatization of the released amino acids with 4-N,N-dimethylaminoazobenzene-4'-sulfonyl chloride (DABS-Cl) which takes only 20 min, makes it possible to do the complete amino acid analysis of an octreotide sample in a few hours. The highly stable-colored DABS-Cl derivatives can be detected in 436 nm in a reversed phase chromatographic system, which eliminates spectral interferences to a great extent. The amino acid analysis of octreotide acetate including hydrolysis, derivatization, and reversed phase HPLC determination was validated according to International Conference of Harmonization (ICH) guidelines.

  19. Direct Surface and Droplet Microsampling for Electrospray Ionization Mass Spectrometry Analysis with an Integrated Dual-Probe Microfluidic Chip

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Cong-Min [Institute of Microanalytical; Zhu, Ying [Institute of Microanalytical; Jin, Di-Qiong [Institute of Microanalytical; Kelly, Ryan T. [Environmental; Fang, Qun [Institute of Microanalytical

    2017-08-15

    Ambient mass spectrometry (MS) has revolutionized the way of MS analysis and broadened its application in various fields. This paper describes the use of microfluidic techniques to simplify the setup and improve the functions of ambient MS by integrating the sampling probe, electrospray emitter probe, and online mixer on a single glass microchip. Two types of sampling probes, including a parallel-channel probe and a U-shaped channel probe, were designed for dryspot and liquid-phase droplet samples, respectively. We demonstrated that the microfabrication techniques not only enhanced the capability of ambient MS methods in analysis of dry-spot samples on various surfaces, but also enabled new applications in the analysis of nanoliter-scale chemical reactions in an array of droplets. The versatility of the microchip-based ambient MS method was demonstrated in multiple different applications including evaluation of residual pesticide on fruit surfaces, sensitive analysis of low-ionizable analytes using postsampling derivatization, and high-throughput screening of Ugi-type multicomponent reactions.

  20. Field test and calibration of neutron coincidence counters for high-mass plutonium samples

    International Nuclear Information System (INIS)

    Menlove, H.O.; Dickinson, R.J.; Douglas, I.

    1987-02-01

    Five different neutron coincidence systems were evaluated and calibrated for high-mass PuO 2 samples. The samples were from 2 to 7.2 kg of PuO 2 in mass, with a large range of burnup. This report compares the equipment and the results, with an evaluation of deadtime and multiplication corrections

  1. A Uniformly Selected Sample of Low-mass Black Holes in Seyfert 1 Galaxies. II. The SDSS DR7 Sample

    Science.gov (United States)

    Liu, He-Yang; Yuan, Weimin; Dong, Xiao-Bo; Zhou, Hongyan; Liu, Wen-Juan

    2018-04-01

    A new sample of 204 low-mass black holes (LMBHs) in active galactic nuclei (AGNs) is presented with black hole masses in the range of (1–20) × 105 M ⊙. The AGNs are selected through a systematic search among galaxies in the Seventh Data Release (DR7) of the Sloan Digital Sky Survey (SDSS), and careful analyses of their optical spectra and precise measurement of spectral parameters. Combining them with our previous sample selected from SDSS DR4 makes it the largest LMBH sample so far, totaling over 500 objects. Some of the statistical properties of the combined LMBH AGN sample are briefly discussed in the context of exploring the low-mass end of the AGN population. Their X-ray luminosities follow the extension of the previously known correlation with the [O III] luminosity. The effective optical-to-X-ray spectral indices α OX, albeit with a large scatter, are broadly consistent with the extension of the relation with the near-UV luminosity L 2500 Å. Interestingly, a correlation of α OX with black hole mass is also found, with α OX being statistically flatter (stronger X-ray relative to optical) for lower black hole masses. Only 26 objects, mostly radio loud, were detected in radio at 20 cm in the FIRST survey, giving a radio-loud fraction of 4%. The host galaxies of LMBHs have stellar masses in the range of 108.8–1012.4 M ⊙ and optical colors typical of Sbc spirals. They are dominated by young stellar populations that seem to have undergone continuous star formation history.

  2. Determination of reduced homocysteine in human serum by elemental labelling and liquid chromatography with ICP-MS and ESI-MS detection.

    Science.gov (United States)

    Espina, Juan Gómez; Montes-Bayón, Maria; Blanco-González, Elisa; Sanz-Medel, Alfredo

    2015-10-01

    Analytical methods allowing sensitive determination of reduced homocysteine (rHcy), one of the so-called biothiols, in human serum is a topic of growing interest due to its close relation to several human disorders, mainly cardiovascular diseases. Although most widely used analytical strategies to determine total Hcy involve derivatization by means of fluorescent labels, this work proposes the use of ebselen, a Se-containing labelling agent to derivatize the reactive sulfhydryl group of the Hcy molecule in its "free" reduced form, which is more likely to play different roles in disease pathogenesis. Optimization of the derivatization and separation conditions by high-performance liquid chromatography (HPLC) to isolate the excess of derivatizing reagent is carried out here using UV/VIS detection. Further, the study of the Se labelling reaction by electrospray ionization tandem mass spectrometry (ESI-MS/MS) provides a stoichiometry of the derivative of 1:1. The main advantage of using ebselen as a labelling agent is the presence of the Se atom in the molecule that allows the use of inductively coupled plasma mass spectrometry (ICP-MS) as a sensitive and selective Se detector. The coupling of HPLC with ICP-MS provided excellent features for the determination of Se-derivatized rHcy (detection limit of 9.6 nM) in real samples. Quantification was accomplished by using post-column isotope dilution (ID) of Se in serum samples, after precipitation of the main serum proteins. Quantitative results for "free" rHcy turned out to be around 0.18-0.22 μM in serum samples from healthy individuals that could be directly analyzed without sample preconcentration.

  3. Detection of Reduced Nitrogen Compounds at Rocknest Using the Sample Analysis At Mars (SAM) Instrument on the Mars Science Laboratory (MSL)

    Science.gov (United States)

    Stern, J. C.; Steele, A.; Brunner, A.; Coll, P.; Eigenbrode, J.; Franz, H. B.; Freissinet, C.; Glavin, D.; Jones, J. H.; Navarro-Gonzalez, R.; hide

    2013-01-01

    The Sample Analysis at Mars (SAM) instrument suite on the Mars Science Laboratory (MSL) Curiosity Rover detected nitrogen-bearing compounds during the pyrolysis of Rocknest material at Gale Crater. Hydrogen cyanide and acetonitrile were identified by the quadrupole mass spectrometer (QMS) both in direct evolved gas analysis (EGA). SAM carried out four separate analyses from Rocknest Scoop 5. A significant low temperature release was present in Rocknest runs 1-4, while a smaller high temperature release was also seen in Rocknest runs 1-3. Here we evaluate whether these compounds are indigenous to Mars or a pyrolysis product resulting from known terrestrial materials that are part of the SAM derivatization.

  4. The potential use of complex derivatization procedures in comprehensive HPLC-MS/MS detection of anabolic steroids.

    Science.gov (United States)

    Baranov, Pavel A; Appolonova, Svetlana A; Rodchenkov, Grigory M

    2010-10-01

    The use of two separate derivatization procedures with the formation of oxime (hydroxyl ammonium pretreatment) and picolinoyl (mixed anhydride method) derivates of anabolic steroids following HPLC-MS/MS analysis was proposed. The main product ions of obtained derivatives for 21 anabolic steroids were evaluated and fragmentation pathways were compared.The analysis of MS/MS spectra for underivatized steroids versus oxime or picolinoyl derivatives showed that in case of analytes containing conjugated double bonds in sterane core all of the observed MS/MS spectra contained abundant product ions of diagnostic value. The implementation of derivatization procedures to such compounds is useful for upgrading sensitivity or selectivity of the evaluated method. On the other hand, MS/MS spectra of underivatized and oxime analytes without conjugated double bonds in sterane core produce spectra with large amounts of low abundant product ions. Picolinoyl derivatives formation leads to highly specific spectra with product ions of diagnostic value coupled with sensitive and selective analysis at the same time. The intra- and inter-group comparison analysis revealed that fragmentation pathways for underivatized steroids and correspondent oxime derivatives are similar.The obtained oxime and picolinoyl derivatives provided 10-15 times higher ESI response in the HPLC-ESI-MS-selected reaction monitoring (SRM) when compared to those of underivatized molecules in positive HPLC-ESI-MS mode.Due to the laborious sample preparation we suggest to use the performed strategy for confirmation analysis purposes, metabolic studies or while the identification of new steroids or steroid-like substances. Copyright © 2010 John Wiley & Sons, Ltd.

  5. Peptide analysis as amino alcohols by gas chromatography-mass spectrometry. Application to hyperoligopeptiduria. Detection of Gly-3Hyp-4Hyp and Gly-Pro-4Hyp-Gly.

    Science.gov (United States)

    Steiner, W; Niederwieser, A

    1979-03-15

    A method for the qualitative analysis of oligopeptides in human urine in cases of peptiduria is described. After sample precleaning on a strongly acidic ion exchanger, the trifluoroacetyl/methyl esters were formed and the peptide derivatives were transformed into trifluoroethyl oligoamino alcohols according to Nau and Biemann. It was found that oligoamino alcohols could be isolated selectively on a weakly acidic ion exchanger. The O-trimethylsilylated trifluoroethyl oligoamino alcohols were separated on a SE-30 glass capillary column and analyzed by computer-assisted gas chromatography-mass spectrometry. In order to increase specificity and to facilitate mass spectrometric interpretation, aliquots of the sample were reduced separately with lithium-aluminium deuteride and hydride. Each peptide gave a pair of derivatives with characteristic mass differences of the ions, namely 2 mass units per reduced oxo group (deuterium-hydrogen-labelling of oxo groups by reduction). Correct identification is assumed only if both mass spectral patterns fit the theory. Sample volumes of 5--100 ml of urine are needed. About six samples can be derivatized per week. Three cases with suspected peptiduria were investigated and the following peptides were found: Gly-Pro-4Hyp-Gly; Gly-Pro-4Hyp; Gly-Hyp-Hyp (postulated isomer Gly-3Hyp-4Hyp); Pro-4Hyp and Gly-Pro. With exception of the tetrapeptide, these compounds could be detected also in the urine of a healthy child.

  6. Search for Chemical Biomarkers on Mars Using the Sample Analysis at Mars Instrument Suite on the Mars Science Laboratory

    Science.gov (United States)

    Glavin, D. P.; Conrad, P.; Dworkin, J. P.; Eigenbrode, J.; Mahaffy, P. R.

    2011-01-01

    One key goal for the future exploration of Mars is the search for chemical biomarkers including complex organic compounds important in life on Earth. The Sample Analysis at Mars (SAM) instrument suite on the Mars Science Laboratory (MSL) will provide the most sensitive measurements of the organic composition of rocks and regolith samples ever carried out in situ on Mars. SAM consists of a gas chromatograph (GC), quadrupole mass spectrometer (QMS), and tunable laser spectrometer to measure volatiles in the atmosphere and released from rock powders heated up to 1000 C. The measurement of organics in solid samples will be accomplished by three experiments: (1) pyrolysis QMS to identify alkane fragments and simple aromatic compounds; pyrolysis GCMS to separate and identify complex mixtures of larger hydrocarbons; and (3) chemical derivatization and GCMS extract less volatile compounds including amino and carboxylic acids that are not detectable by the other two experiments.

  7. Determination of free amino compounds in betalainic fruits and vegetables by gas chromatography with flame ionization and mass spectrometric detection.

    Science.gov (United States)

    Kugler, Florian; Graneis, Stephan; Schreiter, Pat P-Y; Stintzing, Florian C; Carle, Reinhold

    2006-06-14

    Amino acids and amines are the precursors of betalains. Therefore, the profiles of free amino compounds in juices obtained from cactus pears [Opuntia ficus-indica (L.) Mill. cv. Bianca, cv. Gialla, and cv. Rossa], pitaya fruits [Selenicereus megalanthus (K. Schumann ex Vaupel) Moran, Hylocereus polyrhizus (Weber) Britton & Rose, and Hylocereus undatus (Haworth) Britton & Rose], and in extracts from differently colored Swiss chard [Beta vulgaris L. ssp. cicla (L.) Alef. cv. Bright Lights] petioles and red and yellow beets (B. vulgaris L. ssp. vulgaris var. conditiva Alef. cv. Burpee's Golden) were investigated for the first time. Amino compounds were derivatized with propyl chloroformate. While gas chromatography (GC) with mass spectrometry was used for peak assignment, GC flame ionization detection was applied for quantification of individual compounds. Whereas proline was the major free amino compound of cactus pear and pitaya fruit juices, glutamine dominated in Swiss chard stems and beets, respectively. Interestingly, extremely high concentrations of dopamine were detected in Swiss chard stems and beets. Furthermore, the cleavage of betaxanthins caused by derivatization in alkaline reaction solutions is demonstrated for the first time. Amino acids and amines thus released might increase the actual free amino compound contents of the respective sample. To evaluate the contribution of betaxanthin cleavage to total amino acid and amine concentration, isolated betaxanthins were derivatized according to the "EZ:faast" method prior to quantification of the respective amino compounds released. On a molar basis, betaxanthin contribution to overall amino compound contents was always below 6.4%.

  8. Determination of free formaldehyde in cosmetics containing formaldehyde-releasing preservatives by reversed-phase dispersive liquid-liquid microextraction and liquid chromatography with post-column derivatization.

    Science.gov (United States)

    Miralles, Pablo; Chisvert, Alberto; Alonso, M José; Hernandorena, Sandra; Salvador, Amparo

    2018-03-30

    An analytical method for the determination of traces of formaldehyde in cosmetic products containing formaldehyde-releasing preservatives has been developed. The method is based on reversed-phase dispersive liquid-liquid microextraction (RP-DLLME), that allows the extraction of highly polar compounds, followed by liquid chromatography-ultraviolet/visible (LC-UV/vis) determination with post-column derivatization. The variables involved in the RP-DLLME process were studied to provide the best enrichment factors. Under the selected conditions, a mixture of 500 μL of acetonitrile (disperser solvent) and 50 μL of water (extraction solvent) was rapidly injected into 5 mL of toluene sample solution. The extracts were injected into the LC-UV/vis system using phosphate buffer 6 mmol L -1 at pH 2 as mobile phase. After chromatographic separation, the eluate merged with a flow stream of pentane-2,4-dione in ammonium acetate solution as derivatizing reagent and passed throughout a post-column reactor at 85 °C in order to derivatize formaldehyde into 3,5-diacetyl-1,4-dihydrolutidine, according to Hantzsch reaction, which was finally measured spectrophotometrically at 407 nm. The method was successfully validated showing good linearity, an enrichment factor of 86 ± 2, limits of detection and quantification of 0.7 and 2.3 ng mL -1 , respectively, and good repeatability (RSD < 9.2%). Finally, the proposed analytical method was applied to the determination of formaldehyde in different commercial cosmetic samples containing formaldehyde-releasing preservatives, such as bronopol, diazolidinyl urea, imidazolidinyl urea, and DMDM hydantoin, with good relative recovery values (91-113%) thus showing that matrix effects were negligible. The good analytical features of the proposed method besides of its simplicity and affordability, make it useful to carry out the quality control of cosmetic products containing formaldehyde-releasing preservatives. Copyright

  9. Accelerator mass spectrometry of ultra-small samples with applications in the biosciences

    International Nuclear Information System (INIS)

    Salehpour, Mehran; Håkansson, Karl; Possnert, Göran

    2013-01-01

    An overview is presented covering the biological accelerator mass spectrometry activities at Uppsala University. The research utilizes the Uppsala University Tandem laboratory facilities, including a 5 MV Pelletron tandem accelerator and two stable isotope ratio mass spectrometers. In addition, a dedicated sample preparation laboratory for biological samples with natural activity is in use, as well as another laboratory specifically for 14 C-labeled samples. A variety of ongoing projects are described and presented. Examples are: (1) Ultra-small sample AMS. We routinely analyze samples with masses in the 5–10 μg C range. Data is presented regarding the sample preparation method, (2) bomb peak biological dating of ultra-small samples. A long term project is presented where purified and cell-specific DNA from various part of the human body including the heart and the brain are analyzed with the aim of extracting regeneration rate of the various human cells, (3) biological dating of various human biopsies, including atherosclerosis related plaques is presented. The average built up time of the surgically removed human carotid plaques have been measured and correlated to various data including the level of insulin in the human blood, and (4) In addition to standard microdosing type measurements using small pharmaceutical drugs, pre-clinical pharmacokinetic data from a macromolecular drug candidate are discussed.

  10. Accelerator mass spectrometry of ultra-small samples with applications in the biosciences

    Energy Technology Data Exchange (ETDEWEB)

    Salehpour, Mehran, E-mail: mehran.salehpour@physics.uu.se [Department of Physics and Astronomy, Ion Physics, PO Box 516, SE-751 20 Uppsala (Sweden); Hakansson, Karl; Possnert, Goeran [Department of Physics and Astronomy, Ion Physics, PO Box 516, SE-751 20 Uppsala (Sweden)

    2013-01-15

    An overview is presented covering the biological accelerator mass spectrometry activities at Uppsala University. The research utilizes the Uppsala University Tandem laboratory facilities, including a 5 MV Pelletron tandem accelerator and two stable isotope ratio mass spectrometers. In addition, a dedicated sample preparation laboratory for biological samples with natural activity is in use, as well as another laboratory specifically for {sup 14}C-labeled samples. A variety of ongoing projects are described and presented. Examples are: (1) Ultra-small sample AMS. We routinely analyze samples with masses in the 5-10 {mu}g C range. Data is presented regarding the sample preparation method, (2) bomb peak biological dating of ultra-small samples. A long term project is presented where purified and cell-specific DNA from various part of the human body including the heart and the brain are analyzed with the aim of extracting regeneration rate of the various human cells, (3) biological dating of various human biopsies, including atherosclerosis related plaques is presented. The average built up time of the surgically removed human carotid plaques have been measured and correlated to various data including the level of insulin in the human blood, and (4) In addition to standard microdosing type measurements using small pharmaceutical drugs, pre-clinical pharmacokinetic data from a macromolecular drug candidate are discussed.

  11. The Laser Ablation Ion Funnel: Sampling for in situ Mass Spectrometry on Mars

    Science.gov (United States)

    Johnson, Paul V.; Hodyss, Robert; Tang, Keqi; Brinckerhoff, William B.; Smith, Richard D.

    2011-01-01

    A considerable investment has been made by NASA and other space agencies to develop instrumentation suitable for in situ analytical investigation of extra terrestrial bodies including various mass spectrometers (time-of-flight, quadrupole ion trap, quadrupole mass filters, etc.). However, the front-end sample handling that is needed to collect and prepare samples for interrogation by such instrumentation remains underdeveloped. Here we describe a novel approach tailored to the exploration of Mars where ions are created in the ambient atmosphere via laser ablation and then efficiently transported into a mass spectrometer for in situ analysis using an electrodynamic ion funnel. This concept would enable elemental and isotopic analysis of geological samples with the analysis of desorbed organic material a possibility as well. Such an instrument would be suitable for inclusion on all potential missions currently being considered such as the Mid-Range Rover, the Astrobiology Field Laboratory, and Mars Sample Return (i.e., as a sample pre-selection triage instrument), among others.

  12. Determination of NH2 concentration on 3-aminopropyl tri-ethoxy silane layers and cyclopropylamine plasma polymers by liquid-phase derivatization with 5-iodo 2-furaldehyde

    Science.gov (United States)

    Manakhov, Anton; Čechal, Jan; Michlíček, Miroslav; Shtansky, Dmitry V.

    2017-08-01

    The quantification of concentration of primary amines, e.g. in plasma polymerized layers is a very important task for surface analysis. However, the commonly used procedure, such as gas phase derivatization with benzaldehydes, shows several drawbacks, the most important of which are the side reaction effects. In the present study we propose and validate a liquid phase derivatization using 5-iodo 2-furaldehyde (IFA). It was demonstrated that the content of NH2 groups can be determined from the atomic concentrations measured by X-ray photoelectron spectroscopy (XPS), in particular from the ratio of I 3d and N 1s peak intensities. First, we demonstrate the method on a prototypical system such as 3-aminopropyl tri-ethoxy silane (APTES) layer. Here the XPS analysis carried out after reaction of APTES layer with IFA gives the fraction of primary amines (NH2/N) of 38.3 ± 7.9%. Comparing this value with that obtained by N 1s curve fitting of APTES layer giving 40.9 ± 9.5% of amine groups, it can be concluded that all primary amines were derivatized by reaction with IFA. The second system to demonstrate the method comprises cyclopropylamine (CPA) plasma polymers that were free from conjugated imines. In this case the method gives the NH2 fraction ∼8.5%. This value is closely matching the NH2/N ratio estimated by 4-trifluoromethyl benzaldehyde (TFBA) derivatization. The reaction of IFA with CPA plasma polymer exhibiting high density of conjugated imines revealed the NH2/N fraction of ∼10.8%. This value was significantly lower compared to 17.3% estimated by TFBA derivatization. As the overestimated density of primary amines measured by TFBA derivatization is probably related to the side reaction of benzaldehydes with conjugated imines, the proposed IFA derivatization of primary amines can be an alternative procedure for the quantification of surface amine groups.

  13. Offender and offense characteristics of a nonrandom sample of adolescent mass murderers.

    Science.gov (United States)

    Meloy, J R; Hempel, A G; Mohandie, K; Shiva, A A; Gray, B T

    2001-06-01

    The authors conducted a descriptive, archival study of adolescent (murderers-subjects who intentionally killed three or more victims in one event-to identify demographic, clinical, and forensic characteristics. A nonrandom sample of convenience of adolescent mass murderers was utilized. Thirty-four subjects, acting alone or in pairs, committed 27 mass murders between 1958 and 1999. The sample consisted of males with a median age of 17. A majority were described as "loners" and abused alcohol or drugs; almost half were bullied by others, preoccupied with violent fantasy, and violent by history. Although 23% had a documented psychiatric history, only 6% were judged to have been psychotic at the time of the mass murder. Depressive symptoms and historical antisocial behaviors were predominant. There was a precipitating event in most cases--usually a perceived failure in love or school--and most subjects made threatening statements regarding the mass murder to third parties. The majority of the sample clustered into three types: the family annihilator, the classroom avenger, and the criminal opportunist. The adolescent mass murderer is often predatorily rather than affectively violent and typically does not show any sudden or highly emotional warning signs. Although the act of mass murder is virtually impossible to predict because of its extremely low frequency, certain clinical and forensic findings can alert the clinician to the need for further, intensified primary care, including family, school, community, law enforcement, and mental health intervention.

  14. Effects of formic acid hydrolysis on the quantitative analysis of radiation-induced DNA base damage products assayed by gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Swarts, S.G.; Smith, G.S.; Miao, L.; Wheeler, K.T.

    1996-01-01

    Gas chromatography/mass spectrometry (GC/ MS-SIM) is an excellent technique for performing both qualitative and quantitative analysis of DNA base damage products that are formed by exposure to ionizing radiation or by the interaction of intracellular DNA with activated oxygen species. This technique commonly uses a hot formic acid hydrolysis step to degrade the DNA to individual free bases. However, due to the harsh nature of this degradation procedure, the quantitation of DNA base damage products may be adversely affected. Consequently, we examined the effects of various formic acid hydrolysis procedures on the quantitation of a number of DNA base damage products and identified several factors that can influence this quantitation. These factors included (1) the inherent acid stabilities of both the lesions and the internal standards; (2) the hydrolysis temperature; (3) the source and grade of the formic acid; and (4) the sample mass during hydrolysis. Our data also suggested that the N, O-bis (trimethylsilyl)trifluoroacetamide (BSTFA) derivatization efficiency can be adversely affected, presumably by trace contaminants either in the formic acid or from the acid-activated surface of the glass derivatization vials. Where adverse effects were noted, modifications were explored in an attempt to improve the quantitation of these DNA lesions. Although experimental steps could be taken to minimize the influence of these factors on the quantitation of some base damage products, no single procedure solved the quantitation problem for all base lesions. However, a significant improvement in the quantitation was achieved if the relative molecular response factor (RMRF) values for these lesions were generated with authentic DNA base damage products that had been treated exactly like the experimental samples. (orig.)

  15. Fabrication of electrolytic cell for online post-column electrochemical derivatization in ion chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Wu Shuchao [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, Zhejiang (China); Xu Wei [State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310028, Zhejiang (China); Yang Bingcheng [School of Pharmacy, East China University of Science and Technology, Shanghai 200237 (China); Ye Mingli [Thermofisher scientific (China), Shanghai 201203 (China); Zhang Peimin [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, Zhejiang (China); Shentu Chao [College of Biology and Environmental Engineering, Zhejiang Shuren University, Hangzhou 310015 (China); Zhu Yan, E-mail: zhuyan@zju.edu.cn [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, Zhejiang (China)

    2012-07-20

    Highlight: Black-Right-Pointing-Pointer An electrolytic cell including ruthenium modified titanium electrode was fabricated. Black-Right-Pointing-Pointer Ion chromatography/electrochemical derivatization/fluorescence detection was developed. Black-Right-Pointing-Pointer Strong oxidation capacity of this EC was obtained by using the Ru/Ti electrode with large surface area. - Abstract: An electrolytic cell (EC), composed of two ruthenium-plated titanium electrodes separated by cation-exchange membranes, was fabricated and evaluated for online postcolumn derivatization in ion chromatography (IC). Folic acid (FA) and methotrexate (MTX) were preliminarily used as prototype analytes to test the performance of EC. After separation by an anion exchange column, FA and MTX, which emit very weak fluorescence when excited, were electrochemically oxidized online in the anode chamber of the EC. The compounds with strong fluorescence, which are oxidation products, were detected by the fluorescence detector. The phosphate buffer solution (100 mM KH{sub 2}PO{sub 4}) served as an optimal eluent for anion exchange chromatographic separation and a suitable supporting electrolyte for electro-oxidation, leading to ideal compatibility between IC separation and the postcolumn electrochemical derivatization. For the presently proposed method, the linear ranges were from 0.01 mg L{sup -1} to 5 mg L{sup -1} for both FA and MTX. The detection limits of FA and MTX were 1.8 and 2.1 {mu}g L{sup -1}, and the relative standard deviations (RSD, n = 7) were 2.9% and 3.6%, respectively. The method was applied for the simultaneous determination of FA and MTX in the plasma of patients being treated for rheumatoid arthritis. The determination of MTX in the urine of the patients of diffuse large B cell lymphoma was also demonstrated.

  16. Offender and offense characteristics of a nonrandom sample of mass murderers.

    Science.gov (United States)

    Hempel, A G; Meloy, J R; Richards, T C

    1999-01-01

    A nonrandom sample (N = 30) of mass murderers in the United States and Canada during the past 50 years was studied. Data suggest that such individuals are single or divorced males in their fourth decade of life with various Axis I paranoid and/or depressive conditions and Axis II personality traits and disorders, usually Clusters A and B. The mass murder is precipitated by a major loss related to employment or relationship. A warrior mentality suffuses the planning and attack behavior of the subject, and greater deaths and higher casualty rates are significantly more likely if the perpetrator is psychotic at the time of the offense. Alcohol plays a very minor role. A large proportion of subjects will convey their central motivation in a psychological abstract, a phrase or sentence yelled with great emotion at the beginning of the mass murder; but in our study sample, only 20 percent directly threatened their victims before the offense. Death by suicide or at the hands of others is the usual outcome for the mass murderer.

  17. Final LDRD report : development of sample preparation methods for ChIPMA-based imaging mass spectrometry of tissue samples.

    Energy Technology Data Exchange (ETDEWEB)

    Maharrey, Sean P.; Highley, Aaron M.; Behrens, Richard, Jr.; Wiese-Smith, Deneille

    2007-12-01

    The objective of this short-term LDRD project was to acquire the tools needed to use our chemical imaging precision mass analyzer (ChIPMA) instrument to analyze tissue samples. This effort was an outgrowth of discussions with oncologists on the need to find the cellular origin of signals in mass spectra of serum samples, which provide biomarkers for ovarian cancer. The ultimate goal would be to collect chemical images of biopsy samples allowing the chemical images of diseased and nondiseased sections of a sample to be compared. The equipment needed to prepare tissue samples have been acquired and built. This equipment includes an cyro-ultramicrotome for preparing thin sections of samples and a coating unit. The coating unit uses an electrospray system to deposit small droplets of a UV-photo absorbing compound on the surface of the tissue samples. Both units are operational. The tissue sample must be coated with the organic compound to enable matrix assisted laser desorption/ionization (MALDI) and matrix enhanced secondary ion mass spectrometry (ME-SIMS) measurements with the ChIPMA instrument Initial plans to test the sample preparation using human tissue samples required development of administrative procedures beyond the scope of this LDRD. Hence, it was decided to make two types of measurements: (1) Testing the spatial resolution of ME-SIMS by preparing a substrate coated with a mixture of an organic matrix and a bio standard and etching a defined pattern in the coating using a liquid metal ion beam, and (2) preparing and imaging C. elegans worms. Difficulties arose in sectioning the C. elegans for analysis and funds and time to overcome these difficulties were not available in this project. The facilities are now available for preparing biological samples for analysis with the ChIPMA instrument. Some further investment of time and resources in sample preparation should make this a useful tool for chemical imaging applications.

  18. [Confirming Indicators of Qualitative Results by Chromatography-mass Spectrometry in Biological Samples].

    Science.gov (United States)

    Liu, S D; Zhang, D M; Zhang, W; Zhang, W F

    2017-04-01

    Because of the exist of complex matrix, the confirming indicators of qualitative results for toxic substances in biological samples by chromatography-mass spectrometry are different from that in non-biological samples. Even in biological samples, the confirming indicators are different in various application areas. This paper reviews the similarities and differences of confirming indicators for the analyte in biological samples by chromatography-mass spectrometry in the field of forensic toxicological analysis and other application areas. These confirming indicators include retention time (RT), relative retention time (RRT), signal to noise (S/N), characteristic ions, relative abundance of characteristic ions, parent ion-daughter ion pair and abundance ratio of ion pair, etc. Copyright© by the Editorial Department of Journal of Forensic Medicine.

  19. Speciation of organotin compounds in environmental samples by GC-ICPMS

    International Nuclear Information System (INIS)

    Vahcic, M.; Milacic, R.; Scancar, J.

    2009-01-01

    Full text: Analytical procedure using 15 m GC column was applied for simultaneous speciation of OTCs in various environmental samples. Methyl-, butyl-, phenyl- and octyl- tin species were quantitatively determined. different extraction reagents and conditions were studied. OTCs species were derivatized by NaBEt 4 and extracted into isooctane or hexane. The applied analytical procedure considerably shortened analytical time and enabled simultaneous determination of 12 OTCs in environmental samples. (author)

  20. Simultaneous detection of low and high molecular weight carbonylated compounds derived from lipid peroxidation by electrospray ionization-tandem mass spectrometry.

    Science.gov (United States)

    Milic, Ivana; Hoffmann, Ralf; Fedorova, Maria

    2013-01-02

    Reactive oxygen species (ROS) and other oxidative agents such as free radicals can oxidize polyunsaturated fatty acids (PUFA) as well as PUFA in lipids. The oxidation products can undergo consecutive reactions including oxidative cleavages to yield a chemically diverse group of products, such as lipid peroxidation products (LPP). Among them are aldehydes and ketones ("reactive carbonyls") that are strong electrophiles and thus can readily react with nucleophilic side chains of proteins, which can alter the protein structure, function, cellular distribution, and antigenicity. Here, we report a novel technique to specifically derivatize both low molecular and high molecular weight carbonylated LPP with 7-(diethylamino)coumarin-3-carbohydrazide (CHH) and analyze all compounds by electrospray ionization-mass spectrometry (ESI-MS) in positive ion mode. CHH-derivatized compounds were identified by specific neutral losses or fragment ions. The fragment ion spectra displayed additional signals that allowed unambiguous identification of the lipid, fatty acids, cleavage sites, and oxidative modifications. Oxidation of docosahexaenoic (DHA, 22:6), arachidonic (AA, 20:4), linoleic (LA, 18:2), and oleic acids (OA, 18:1) yielded 69 aliphatic carbonyls, whose structures were all deduced from the tandem mass spectra. When four phosphatidylcholine (PC) vesicles containing the aforementioned unsaturated fatty acids were oxidized, we were able to deduce the structures of 122 carbonylated compounds from the tandem mass spectra of a single shotgun analysis acquired within 15 min. The high sensitivity (LOD ∼ 1 nmol/L for 4-hydroxy-2-nonenal, HNE) and a linear range of more than 3 orders of magnitude (10 nmol/L to 10 μmol/L for HNE) will allow further studies on complex biological samples including plasma.

  1. Feasibility of gas chromatography-microchip atmospheric pressure photoionization-mass spectrometry in analysis of anabolic steroids.

    Science.gov (United States)

    Hintikka, Laura; Haapala, Markus; Franssila, Sami; Kuuranne, Tiia; Leinonen, Antti; Kostiainen, Risto

    2010-12-24

    Mass spectrometers equipped with atmospheric pressure ion sources (API-MS) have been designed to be interfaced with liquid chromatographs (LC) and have rarely been connected to gas chromatographs (GC). Recently, we introduced a heated nebulizer microchip and showed its potential to interface liquid microseparation techniques and GC with API-MS. This study demonstrates the feasibility of GC-microchip atmospheric pressure photoionization-tandem mass spectrometry (GC-μAPPI-MS/MS) in the analysis of underivatized anabolic steroids in urine. The APPI microchip provides high ionization efficiency and produces abundant protonated molecules or molecular ions with minimal fragmentation. The feasibility of GC-μAPPI-MS/MS in the analysis of six selected anabolic steroids in urine samples was studied with respect to intra-batch repeatability, linearity, linear range, and limit of detection (LOD). The method showed good sensitivity (LODs 0.2-1 ng/mL), repeatability (relative standard deviationanabolic steroids. Quantitative performance of the method was tested with two authentic urine samples, and the results were in good agreement with those obtained with conventional GC-electron ionization-MS after derivatization. Copyright © 2010 Elsevier B.V. All rights reserved.

  2. Multi-elemental analysis of aqueous geochemical samples by quadrupole inductively coupled plasma-mass spectrometry (ICP-MS)

    Science.gov (United States)

    Wolf, Ruth E.; Adams, Monique

    2015-01-01

    Typically, quadrupole inductively coupled plasma-mass spectrometry (ICP-MS) is used to determine as many as 57 major, minor, and trace elements in aqueous geochemical samples, including natural surface water and groundwater, acid mine drainage water, and extracts or leachates from geological samples. The sample solution is aspirated into the inductively coupled plasma (ICP) which is an electrodeless discharge of ionized argon gas at a temperature of approximately 6,000 degrees Celsius. The elements in the sample solution are subsequently volatilized, atomized, and ionized by the ICP. The ions generated are then focused and introduced into a quadrupole mass filter which only allows one mass to reach the detector at a given moment in time. As the settings of the mass analyzer change, subsequent masses are allowed to impact the detector. Although the typical quadrupole ICP-MS system is a sequential scanning instrument (determining each mass separately), the scan speed of modern instruments is on the order of several thousand masses per second. Consequently, typical total sample analysis times of 2–3 minutes are readily achievable for up to 57 elements.

  3. LC determination of propylene glycol in human plasma after pre-column derivatization with benzoyl chloride

    NARCIS (Netherlands)

    Sinjewel, A.; Swart, E.L.; Lingeman, H.; Wilhelm, A.J.

    2007-01-01

    A simple high-performance liquid chromatographic method, using photodiode array detection was developed for the determination of propylene glycol in human plasma and in the fluid retreived after continuous veno-venous hemofiltration. The method entailed alkaline derivatization with benzoyl chloride

  4. Determination of D- and L-amino acids produced by cyanobacteria using gas chromatography on Chirasil-Val after derivatization with pentafluoropropyl chloroformate.

    Science.gov (United States)

    Zahradnícková, Helena; Husek, Petr; Simek, Petr; Hartvich, Petr; Marsálek, Blahoslav; Holoubek, Ivan

    2007-08-01

    A rapid and simple method was developed for the determination of free amino acids (AAs) released from cyanobacteria. The procedure involves trapping of AAs from the centrifuged cyanobacterial culture fluid on a cation-exchange resin, their release together with the resin by direct treatment with the reaction medium, followed by immediate derivatization with a corresponding chloroformate. The extractive alkylation transfers the analytes into an organic phase, an aliquot of which is subjected to GC analysis. Identification and quantification of AAs was performed by GC/MS and GC/FID, respectively, using propyl chloroformate (PCF) as the derivatization reagent. For chiral analysis, the cyanobacteria extracts were treated with 2,2,3,3,3-pentafluoropropyl chloroformate (PFPCF) to create more volatile analytes. Separation of the AA enantiomers was accomplished on a Chirasil-Val capillary column and the D/L enantiomeric ratios were determined. AAs of cyanobacteria are considered to be important for the assessment of energy flow in an aquatic food web, nutrition value of cyanobacteria in a food web and for cell-cell communication within cyanobacteria. The highest levels of AAs were found in the summer period at the beginning of the season (July). In the September and October samples, the amount of AAs was lower, the number of D-AAs decreased and the D/L ratio was higher than in the July sample. Based on the obtained results it can be assumed that young populations excrete AAs in higher concentrations and a different composition compared to actively growing populations.

  5. Isotopic abundance measurements on solid nuclear-type samples by glow discharge mass spectrometry

    International Nuclear Information System (INIS)

    Betti, M.; Rasmussen, G.; Koch, L.

    1996-01-01

    A double-focusing glow discharge mass spectrometer (GDMS) installed in a glovebox for nuclear sample screening has been employed for isotopic measurements. Isotopic compositions of zirconium, silicon, lithium, boron, uranium and plutonium which are elements of nuclear concern have been determined. Interferences arising from the matrix sample and the discharge gas (Ar) for each of these elements are discussed. The GDMS results are compared with those from thermal ionization mass spectrometry (TIMS). For boron and lithium at μg/g-ng/g levels, the two methods gave results in good agreement. In samples containing uranium the isotopic composition obtained by GDMS was in agreement with those from TIMS independently of the enrichment. Attempts for the determination of plutonium isotopic composition were also made. In this case, due to the interferences of uranium at mass 238 and americium at mass 241, the GDMS raw data are complementary with those values obtained from physical non-destructive techniques. (orig.). With 2 figs., 4 tabs

  6. Novel protocol for highly efficient gas-phase chemical derivatization of surface amine groups using trifluoroacetic anhydride

    Science.gov (United States)

    Duchoslav, Jiri; Kehrer, Matthias; Hinterreiter, Andreas; Duchoslav, Vojtech; Unterweger, Christoph; Fürst, Christian; Steinberger, Roland; Stifter, David

    2018-06-01

    In the current work, chemical derivatization of amine (NH2) groups with trifluoroacetic anhydride (TFAA) as an analytical method to improve the information scope of X-ray photoelectron spectroscopy (XPS) is investigated. TFAA is known to successfully label hydroxyl (OH) groups. With the introduction of a newly developed gas-phase derivatization protocol conducted at ambient pressure and using a catalyst also NH2 groups can now efficiently be labelled with a high yield and without the formation of unwanted by-products. By establishing a comprehensive and self-consistent database of reference binding energies for XPS a promising approach for distinguishing hydroxyl from amine groups is presented. The protocol was verified on different polymers, including poly(allylamine), poly(ethyleneimine), poly(vinylalcohol) and chitosan, the latter one containing both types of addressed chemical groups.

  7. Determination of monosaccharides derivatized with 2-aminobenzoic Acid by capillary electrophoresis.

    Science.gov (United States)

    Abo, Mitsuru; He, Li-Ping; Sato, Kae; Okubo, Akira

    2013-01-01

    Reducing monosaccharides were derivatized with 2-aminobenzoic acid (2-AA) through reductive amination using sodium cyanoborohydride as a reductant, and the derivatives were separated by capillary zone electrophoresis with UV detection using 50 mM sodium phosphate (pH 5.5) or 150 mM sodium borate-50 mM sodium phosphate (pH 7.0) running buffer. The derivatives of monosaccharides, which are major components of various carbohydrate materials, were completely separated within 25 min.

  8. Speciation of mercury by ion chromatography with post-column derivatization

    International Nuclear Information System (INIS)

    Foltin, M.; Megova, S.; Prochakova, T.; Steklac, M.

    1996-01-01

    The chromatographic behaviour of Hg(II), methylmercury, phenylmercury and Cu(II) on three different sorbents, strong acidic sulfobutyl cation-exchanger, weak basic aminopropyl anion-exchanger and silicagel has been studied. A dithizone solution in cetyltrimethylammonium hydrogensulfate water micellar medium was found as a useful post-column derivatization reagent for UV-VIS detection. The detection limits 1.1 ng, 2.2 ng, 6.2 ng and 1.6 ng were found in silicagel chromatographic system and dithizone detection system for Hg(II), methylmercury, phenylmercury and respectively for Cu(II). (author). 18 refs., 4 figs., 3 tabs

  9. The determination of precious metals in geological samples by ICP - Mass Spectrometry

    International Nuclear Information System (INIS)

    Denoyer, E.; Ediger, R.; Hager, J.

    1989-01-01

    ICP - mass spectrometry with laser sampling has been used to determine gold directly in solid fire assay beads. A small portion of the lead bead is vaporized by Nd: YAG laser, and the resulting particulate material is passed by a flow of argon an ICP-mass spectrometer for quantitation of the gold content. Calibration with known geological materials gives linear calibration curves, and detection limits for gols are estimated to be 0.07 micrograms/gram in the original ore sample. The repeatability of the method is similar to that expected for traditional fire assay methods, and the analysis time for the solid lead bead is less than five minutes per sample. (author) [pt

  10. The Recent Developments in Sample Preparation for Mass Spectrometry-Based Metabolomics.

    Science.gov (United States)

    Gong, Zhi-Gang; Hu, Jing; Wu, Xi; Xu, Yong-Jiang

    2017-07-04

    Metabolomics is a critical member in systems biology. Although great progress has been achieved in metabolomics, there are still some problems in sample preparation, data processing and data interpretation. In this review, we intend to explore the roles, challenges and trends in sample preparation for mass spectrometry- (MS-) based metabolomics. The newly emerged sample preparation methods were also critically examined, including laser microdissection, in vivo sampling, dried blood spot, microwave, ultrasound and enzyme-assisted extraction, as well as microextraction techniques. Finally, we provide some conclusions and perspectives for sample preparation in MS-based metabolomics.

  11. A targeted metabolomic protocol for short-chain fatty acids and branched-chain amino acids

    OpenAIRE

    Zheng, Xiaojiao; Qiu, Yunping; Zhong, Wei; Baxter, Sarah; Su, Mingming; Li, Qiong; Xie, Guoxiang; Ore, Brandon M.; Qiao, Shanlei; Spencer, Melanie D.; Zeisel, Steven H.; Zhou, Zhanxiang; Zhao, Aihua; Jia, Wei

    2013-01-01

    Research in obesity and metabolic disorders that involve intestinal microbiota demands reliable methods for the precise measurement of the short-chain fatty acids (SCFAs) and branched-chain amino acids (BCAAs) concentration. Here, we report a rapid method of simultaneously determining SCFAs and BCAAs in biological samples using propyl chloroformate (PCF) derivatization followed by gas chromatography mass spectrometry (GC-MS) analysis. A one-step derivatization using 100 µL of PCF in a reactio...

  12. A Probabilistic Mass Estimation Algorithm for a Novel 7- Channel Capacitive Sample Verification Sensor

    Science.gov (United States)

    Wolf, Michael

    2012-01-01

    A document describes an algorithm created to estimate the mass placed on a sample verification sensor (SVS) designed for lunar or planetary robotic sample return missions. A novel SVS measures the capacitance between a rigid bottom plate and an elastic top membrane in seven locations. As additional sample material (soil and/or small rocks) is placed on the top membrane, the deformation of the membrane increases the capacitance. The mass estimation algorithm addresses both the calibration of each SVS channel, and also addresses how to combine the capacitances read from each of the seven channels into a single mass estimate. The probabilistic approach combines the channels according to the variance observed during the training phase, and provides not only the mass estimate, but also a value for the certainty of the estimate. SVS capacitance data is collected for known masses under a wide variety of possible loading scenarios, though in all cases, the distribution of sample within the canister is expected to be approximately uniform. A capacitance-vs-mass curve is fitted to this data, and is subsequently used to determine the mass estimate for the single channel s capacitance reading during the measurement phase. This results in seven different mass estimates, one for each SVS channel. Moreover, the variance of the calibration data is used to place a Gaussian probability distribution function (pdf) around this mass estimate. To blend these seven estimates, the seven pdfs are combined into a single Gaussian distribution function, providing the final mean and variance of the estimate. This blending technique essentially takes the final estimate as an average of the estimates of the seven channels, weighted by the inverse of the channel s variance.

  13. Mass spectrometry in grape and wine chemistry. Part II: The consumer protection.

    Science.gov (United States)

    Flamini, Riccardo; Panighel, Annarita

    2006-01-01

    Controls in food industry are fundamental to protect the consumer health. For products of high quality, warranty of origin and identity is required and analytical control is very important to prevent frauds. In this article, the "state of art" of mass spectrometry in enological chemistry as a consumer safety contribute is reported. Gas chromatography-mass spectrometry (GC/MS) and liquid-chromatography-mass spectrometry (LC/MS) methods have been developed to determine pesticides, ethyl carbamate, and compounds from the yeast and bacterial metabolism in wine. The presence of pesticides in wine is mainly linked to the use of dicarboxyimide fungicides on vineyard shortly before the harvest to prevent the Botrytis cinerea attack of grape. Pesticide residues are regulated at maximum residue limits in grape of low ppm levels, but significantly lower levels in wine have to be detected, and mass spectrometry offers effective and sensitive methods. Moreover, mass spectrometry represent an advantageous alternative to the radioactive-source-containing electron capture detector commonly used in GC analysis of pesticides. Analysis of ochratoxin A (OTA) in wine by LC/MS and multiple mass spectrometry (MS/MS) permits to confirm the toxin presence without the use of expensive immunoaffinity columns, or time and solvent consuming sample derivatization procedures. Inductively coupled plasma-mass spectrometry (ICP/MS) is used to control heavy metals contamination in wine, and to verify the wine origin and authenticity. Isotopic ratio-mass spectrometry (IRMS) is applied to reveal wine watering and sugar additions, and to determine the product origin and traceability.

  14. Multiwalled carbon nanotubes as a solid-phase extraction adsorbent for the determination of three barbiturates in pork by ion trap gas chromatography-tandem mass spectrometry (GC/MS/MS) following microwave assisted derivatization

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Haixiang [College of Science, China Agricultural University, Beijing 100094 (China); Inspection Technology and Equipment Institute, Chinese Academy of Inspection and Quarantine, Beijing 100025 (China); Department of Basic Agricultural Science, Hebei North College, Zhangjiakou Hebei 075131 (China); Wang Liping [College of Science, China Agricultural University, Beijing 100094 (China); Qiu Yueming [Inspection Technology and Equipment Institute, Chinese Academy of Inspection and Quarantine, Beijing 100025 (China); Zhou Zhiqiang [College of Science, China Agricultural University, Beijing 100094 (China)]. E-mail: zqzhou@cau.edu.cn; Zhong Weike [Inspection Technology and Equipment Institute, Chinese Academy of Inspection and Quarantine, Beijing 100025 (China); Li Xiang [Inspection Technology and Equipment Institute, Chinese Academy of Inspection and Quarantine, Beijing 100025 (China)

    2007-03-14

    A new method was developed for the rapid screening and confirmation analysis of barbital, amobarbital and phenobarbital residues in pork by gas chromatography-tandem mass spectrometry (GC/MS/MS) with ion trap MSD. The residual barbiturates in pork were extracted by ultrasonic extraction, cleaned up on a multiwalled carbon nanotubes (MWCNTs) packed solid phase extraction (SPE) cartridge and applied acetone-ethyl acetate (3:7, v/v) mixture as eluting solvent and derivatized with CH{sub 3}I under microwave irradiation. The methylated barbiturates were separated on a TR-5MS capillary column and detected with an ion trap mass detector. Electron impact ion source (EI) operating MS/MS mode was adopted for identification and external standard method was employed for quantification. One precursor ion m/z 169 was selected for analysis of barbital and amobarbital and m/z 232 was selected for phenobarbital. The product ions were obtained under 1.0 V excitation voltage. Good linearities (linear coefficient R > 0.99) were obtained at the range of 0.5-50 {mu}g kg{sup -1}. Limit of detection (LOD) of barbital was 0.2 {mu}g kg{sup -1} and that of amobarbital and phenobarbital were both 0.1 {mu}g kg{sup -1} (S/N {>=} 3). Limit of quatification (LOQ) was 0.5 {mu}g kg{sup -1} for three barbiturates (S/N {>=} 10). Satisfying recoveries ranging from 75% to 96% of the three barbiturates spiked in pork were obtained, with relative standard deviations (R.S.D.) in the range of 2.1-7.8%.

  15. Multiwalled carbon nanotubes as a solid-phase extraction adsorbent for the determination of three barbiturates in pork by ion trap gas chromatography-tandem mass spectrometry (GC/MS/MS) following microwave assisted derivatization

    International Nuclear Information System (INIS)

    Zhao Haixiang; Wang Liping; Qiu Yueming; Zhou Zhiqiang; Zhong Weike; Li Xiang

    2007-01-01

    A new method was developed for the rapid screening and confirmation analysis of barbital, amobarbital and phenobarbital residues in pork by gas chromatography-tandem mass spectrometry (GC/MS/MS) with ion trap MSD. The residual barbiturates in pork were extracted by ultrasonic extraction, cleaned up on a multiwalled carbon nanotubes (MWCNTs) packed solid phase extraction (SPE) cartridge and applied acetone-ethyl acetate (3:7, v/v) mixture as eluting solvent and derivatized with CH 3 I under microwave irradiation. The methylated barbiturates were separated on a TR-5MS capillary column and detected with an ion trap mass detector. Electron impact ion source (EI) operating MS/MS mode was adopted for identification and external standard method was employed for quantification. One precursor ion m/z 169 was selected for analysis of barbital and amobarbital and m/z 232 was selected for phenobarbital. The product ions were obtained under 1.0 V excitation voltage. Good linearities (linear coefficient R > 0.99) were obtained at the range of 0.5-50 μg kg -1 . Limit of detection (LOD) of barbital was 0.2 μg kg -1 and that of amobarbital and phenobarbital were both 0.1 μg kg -1 (S/N ≥ 3). Limit of quatification (LOQ) was 0.5 μg kg -1 for three barbiturates (S/N ≥ 10). Satisfying recoveries ranging from 75% to 96% of the three barbiturates spiked in pork were obtained, with relative standard deviations (R.S.D.) in the range of 2.1-7.8%

  16. High-Throughput and Rapid Screening of Low-Mass Hazardous Compounds in Complex Samples.

    Science.gov (United States)

    Wang, Jing; Liu, Qian; Gao, Yan; Wang, Yawei; Guo, Liangqia; Jiang, Guibin

    2015-07-07

    Rapid screening and identification of hazardous chemicals in complex samples is of extreme importance for public safety and environmental health studies. In this work, we report a new method for high-throughput, sensitive, and rapid screening of low-mass hazardous compounds in complex media without complicated sample preparation procedures. This method is achieved based on size-selective enrichment on ordered mesoporous carbon followed by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry analysis with graphene as a matrix. The ordered mesoporous carbon CMK-8 can exclude interferences from large molecules in complex samples (e.g., human serum, urine, and environmental water samples) and efficiently enrich a wide variety of low-mass hazardous compounds. The method can work at very low concentrations down to part per trillion (ppt) levels, and it is much faster and more facile than conventional methods. It was successfully applied to rapidly screen and identify unknown toxic substances such as perfluorochemicals in human serum samples from athletes and workers. Therefore, this method not only can sensitively detect target compounds but also can identify unknown hazardous compounds in complex media.

  17. Sample preparation method for the speciation of polybrominated diphenyl ethers and their methoxylated and hydroxylated analogues in diverse environmental matrices.

    Science.gov (United States)

    Sun, Jianteng; Liu, Jiyan; Liu, Qian; Qu, Guangbo; Ruan, Ting; Jiang, Guibin

    2012-01-15

    A reliable analytical method was developed here for the simultaneous separation, identification and quantification of ten polybrominated diphenyl ethers (PBDEs), nine methoxylated PBDEs (MeO-PBDEs) and ten hydroxylated PBDEs (OH-PBDEs) in various environmental matrices, including water, soil, sediment, plant, mollusk and fish. PBDEs and MeO-PBDEs were measured by gas chromatography coupled with mass spectrometry (GC/MS) and liquid chromatography coupled with electrospray ionization (negative)-tandem quadrupole mass spectrometry (LC/ESI(-)-MS/MS) for the separation and determination of OH-PBDEs without prior derivatization. After preliminary sample cleaning using acid silica gel, water-impregnated silica column separation of PBDEs, MeO-PBDEs and OH-PBDEs was proved to be rapid, simple, and efficient. For phenolic analytes, the method detection limits (MDLs) were 3.2-11.6pg/L in water sample and 2.8-18.4pg/g dry weight in solid samples. For neutral compounds, MDLs were 48.8-150.3pg/L in water sample and 46.5-170.8pg/g dry weight in solid samples. The method was validated using six kinds of environmental samples spiked with all analytes at three concentration levels (0.3ng, 2ng and 5ng, respectively) for recovery (71-113%) and repeatability determination (4-12%RSD). Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Occurrence of Radio Minihalos in a Mass-limited Sample of Galaxy Clusters

    Energy Technology Data Exchange (ETDEWEB)

    Giacintucci, Simona; Clarke, Tracy E. [Naval Research Laboratory, 4555 Overlook Avenue SW, Code 7213, Washington, DC 20375 (United States); Markevitch, Maxim [NASA/Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Cassano, Rossella; Venturi, Tiziana; Brunetti, Gianfranco, E-mail: simona.giacintucci@nrl.navy.mil [INAF—Istituto di Radioastronomia, via Gobetti 101, I-40129 Bologna (Italy)

    2017-06-01

    We investigate the occurrence of radio minihalos—diffuse radio sources of unknown origin observed in the cores of some galaxy clusters—in a statistical sample of 58 clusters drawn from the Planck Sunyaev–Zel’dovich cluster catalog using a mass cut ( M {sub 500} > 6 × 10{sup 14} M {sub ⊙}). We supplement our statistical sample with a similarly sized nonstatistical sample mostly consisting of clusters in the ACCEPT X-ray catalog with suitable X-ray and radio data, which includes lower-mass clusters. Where necessary (for nine clusters), we reanalyzed the Very Large Array archival radio data to determine whether a minihalo is present. Our total sample includes all 28 currently known and recently discovered radio minihalos, including six candidates. We classify clusters as cool-core or non-cool-core according to the value of the specific entropy floor in the cluster center, rederived or newly derived from the Chandra X-ray density and temperature profiles where necessary (for 27 clusters). Contrary to the common wisdom that minihalos are rare, we find that almost all cool cores—at least 12 out of 15 (80%)—in our complete sample of massive clusters exhibit minihalos. The supplementary sample shows that the occurrence of minihalos may be lower in lower-mass cool-core clusters. No minihalos are found in non-cool cores or “warm cores.” These findings will help test theories of the origin of minihalos and provide information on the physical processes and energetics of the cluster cores.

  19. Quantifying Protein-Carbohydrate Interactions Using Liquid Sample Desorption Electrospray Ionization Mass Spectrometry

    Science.gov (United States)

    Yao, Yuyu; Shams-Ud-Doha, Km; Daneshfar, Rambod; Kitova, Elena N.; Klassen, John S.

    2015-01-01

    The application of liquid sample desorption electrospray ionization mass spectrometry (liquid sample DESI-MS) for quantifying protein-carbohydrate interactions in vitro is described. Association constants for the interactions between lysozyme and β-D-GlcNAc-(1 → 4)-β-D-GlcNAc-(1 → 4)-D-GlcNAc and β-D-GlcNAc-(1 → 4)-β-D-GlcNAc-(1 → 4)-β-D-GlcNAc-(1 → 4)-D-GlcNAc, and between a single chain antibody and α-D-Galp-(1 → 2)-[α-D-Abep-(1 → 3)]-α-D-Manp-OCH3 and β-D-Glcp-(1 → 2)-[α-D-Abep-(1 → 3)]-α-D-Manp-OCH3 measured using liquid sample DESI-MS were found to be in good agreement with values measured by isothermal titration calorimetry and the direct ESI-MS assay. The reference protein method, which was originally developed to correct ESI mass spectra for the occurrence of nonspecific ligand-protein binding, was shown to reliably correct liquid sample DESI mass spectra for nonspecific binding. The suitability of liquid sample DESI-MS for quantitative binding measurements carried out using solutions containing high concentrations of the nonvolatile biological buffer phosphate buffered saline (PBS) was also explored. Binding of lysozyme to β-D-GlcNAc-(1 → 4)-β-D-GlcNAc-(1 → 4)-D-GlcNAc in aqueous solutions containing up to 1× PBS was successfully monitored using liquid sample DESI-MS; with ESI-MS the binding measurements were limited to concentrations less than 0.02 X PBS.

  20. Bioanalysis of 6-Diazo-5-oxo-L-norleucine (DON) in plasma and brain by ultra-performance liquid chromatography mass spectrometry

    Science.gov (United States)

    Alt, Jesse; Potter, Michelle C.; Rojas, Camilo; Slusher, Barbara S.

    2015-01-01

    Glutamine is an abundant amino acid that plays pivotal roles in cell growth, cell metabolism and neurotransmission. Dysregulation of glutamine-utilizing pathways has been associated with pathological conditions such as cancer and neurodegenerative diseases. 6-Diazo-5-Oxo-L-Norleucine (DON) is a reactive glutamine analog that inhibits enzymes affecting glutamine metabolism such as glutaminase, 2-N-amidotransferase, L-asparaginase and several enzymes involved in pyrimidine and purine de novo synthesis. As a result, DON is actively used in preclinical models of cancer and neurodegenerative disease. Moreover, there have been several clinical trials using DON to treat a variety of cancers. Considerations of dose and exposure are especially important with DON treatment due to its narrow therapeutic window and significant side effects. Consequently, a robust quantification bioassay is of interest. DON is a polar unstable molecule which has made quantification challenging. Here we report on the characterization of a bioanalytical method to quantify DON in tissue samples involving DON derivatization with 3N HCl in butanol. The derivatized product is lipophilic and stable. Detection of this analyte by mass spectrometry is fast, specific and can be used to quantify DON in plasma and brain tissue with a limit of detection in the low nanomolar level. PMID:25584882

  1. Classification of bacteria by simultaneous methylation-solid phase microextraction and gas chromatography/mass spectrometry analysis of fatty acid methyl esters.

    Science.gov (United States)

    Lu, Yao; Harrington, Peter B

    2010-08-01

    Direct methylation and solid-phase microextraction (SPME) were used as a sample preparation technique for classification of bacteria based on fatty acid methyl ester (FAME) profiles. Methanolic tetramethylammonium hydroxide was applied as a dual-function reagent to saponify and derivatize whole-cell bacterial fatty acids into FAMEs in one step, and SPME was used to extract the bacterial FAMEs from the headspace. Compared with traditional alkaline saponification and sample preparation using liquid-liquid extraction, the method presented in this work avoids using comparatively large amounts of inorganic and organic solvents and greatly decreases the sample preparation time as well. Characteristic gas chromatography/mass spectrometry (GC/MS) of FAME profiles was achieved for six bacterial species. The difference between Gram-positive and Gram-negative bacteria was clearly visualized with the application of principal component analysis of the GC/MS data of bacterial FAMEs. A cross-validation study using ten bootstrap Latin partitions and the fuzzy rule building expert system demonstrated 87 +/- 3% correct classification efficiency.

  2. Proteomic Biomarker Discovery in 1000 Human Plasma Samples with Mass Spectrometry.

    Science.gov (United States)

    Cominetti, Ornella; Núñez Galindo, Antonio; Corthésy, John; Oller Moreno, Sergio; Irincheeva, Irina; Valsesia, Armand; Astrup, Arne; Saris, Wim H M; Hager, Jörg; Kussmann, Martin; Dayon, Loïc

    2016-02-05

    The overall impact of proteomics on clinical research and its translation has lagged behind expectations. One recognized caveat is the limited size (subject numbers) of (pre)clinical studies performed at the discovery stage, the findings of which fail to be replicated in larger verification/validation trials. Compromised study designs and insufficient statistical power are consequences of the to-date still limited capacity of mass spectrometry (MS)-based workflows to handle large numbers of samples in a realistic time frame, while delivering comprehensive proteome coverages. We developed a highly automated proteomic biomarker discovery workflow. Herein, we have applied this approach to analyze 1000 plasma samples from the multicentered human dietary intervention study "DiOGenes". Study design, sample randomization, tracking, and logistics were the foundations of our large-scale study. We checked the quality of the MS data and provided descriptive statistics. The data set was interrogated for proteins with most stable expression levels in that set of plasma samples. We evaluated standard clinical variables that typically impact forthcoming results and assessed body mass index-associated and gender-specific proteins at two time points. We demonstrate that analyzing a large number of human plasma samples for biomarker discovery with MS using isobaric tagging is feasible, providing robust and consistent biological results.

  3. Radon mass exhalation rate in soil samples at South Bengaluru city, Karnataka, India

    International Nuclear Information System (INIS)

    Poojitha, C.G.; Pranesha, T.S.; Ganesh, K.E.; Sahoo, B.K.; Sapra, B.K.

    2017-01-01

    Radon mass exhalation rate in soil samples collected from different locations of South Bengaluru city were measured using scintillation based Smart radon thoron monitor (RnDuo). It has been observed that the mass exhalation rate estimated due to presence of radon concentration in soil samples ranges from 39.18 - 265.58 mBq/kg/h with an average value of 115.64 mBq/kg/h. Finally we compare our results with similar investigation from different parts of India. (author)

  4. Identification of Vitamin D3 Oxidation Products Using High-Resolution and Tandem Mass Spectrometry

    Science.gov (United States)

    Mahmoodani, Fatemeh; Perera, Conrad O.; Abernethy, Grant; Fedrizzi, Bruno; Greenwood, David; Chen, Hong

    2018-03-01

    In a successful fortification program, the stability of micronutrients added to the food is one of the most important factors. The added vitamin D3 is known to sometimes decline during storage of fortified milks, and oxidation through fatty acid lipoxidation could be suspected as the likely cause. Identification of vitamin D3 oxidation products (VDOPs) in natural foods is a challenge due to the low amount of their contents and their possible transformation to other compounds during analysis. The main objective of this study was to find a method to extract VDOPs in simulated whole milk powder and to identify these products using LTQ-ion trap, Q-Exactive Orbitrap and triple quadrupole mass spectrometry. The multistage mass spectrometry (MSn) spectra can help to propose plausible schemes for unknown compounds and their fragmentations. With the growth of combinatorial libraries, mass spectrometry (MS) has become an important analytical technique because of its speed of analysis, sensitivity, and accuracy. This study was focused on identifying the fragmentation rules for some VDOPs by incorporating MS data with in silico calculated MS fragmentation pathways. Diels-Alder derivatization was used to enhance the sensitivity and selectivity for the VDOPs' identification. Finally, the confirmed PTAD-derivatized target compounds were separated and analyzed using ESI(+)-UHPLC-MS/MS in multiple reaction monitoring (MRM) mode. [Figure not available: see fulltext.

  5. Sample Preparation for Determination of Biological Thiols by Liquid Chromatography and Electromigration Techniques

    OpenAIRE

    Bald, Edward

    2004-01-01

    Wydrukowano z dostarczonych Wydawnictwu UŁ gotowych materiałów Majority of the bioanalytical or environmental methods do not use just one chromatografie or electrophoretic step, but rather involve several sample pretreatment steps which simplfy the matrix, and often preconcentrate and chemically modify the analytes. This work surveys typical procedures for sample preparation for most commonly analyzed biofluids with particular emphasis placed on chemical derivatization of su...

  6. Metabolic profiling of yeast culture using gas chromatography coupled with orthogonal acceleration accurate mass time-of-flight mass spectrometry: application to biomarker discovery.

    Science.gov (United States)

    Kondo, Elsuida; Marriott, Philip J; Parker, Rhiannon M; Kouremenos, Konstantinos A; Morrison, Paul; Adams, Mike

    2014-01-07

    Yeast and yeast cultures are frequently used as additives in diets of dairy cows. Beneficial effects from the inclusion of yeast culture in diets for dairy mammals have been reported, and the aim of this study was to develop a comprehensive analytical method for the accurate mass identification of the 'global' metabolites in order to differentiate a variety of yeasts at varying growth stages (Diamond V XP, Yea-Sacc and Levucell). Microwave-assisted derivatization for metabolic profiling is demonstrated through the analysis of differing yeast samples developed for cattle feed, which include a wide range of metabolites of interest covering a large range of compound classes. Accurate identification of the components was undertaken using GC-oa-ToFMS (gas chromatography-orthogonal acceleration-time-of-flight mass spectrometry), followed by principal component analysis (PCA) and orthogonal partial least squares discriminant analysis (OPLS-DA) for data reduction and biomarker discovery. Semi-quantification (fold changes in relative peak areas) was reported for metabolites identified as possible discriminative biomarkers (p-value 2), including D-ribose (four fold decrease), myo-inositol (five fold increase), L-phenylalanine (three fold increase), glucopyranoside (two fold increase), fructose (three fold increase) and threitol (three fold increase) respectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Planck/SDSS Cluster Mass and Gas Scaling Relations for a Volume-Complete redMaPPer Sample

    Science.gov (United States)

    Jimeno, Pablo; Diego, Jose M.; Broadhurst, Tom; De Martino, I.; Lazkoz, Ruth

    2018-04-01

    Using Planck satellite data, we construct Sunyaev-Zel'dovich (SZ) gas pressure profiles for a large, volume-complete sample of optically selected clusters. We have defined a sample of over 8,000 redMaPPer clusters from the Sloan Digital Sky Survey (SDSS), within the volume-complete redshift region 0.100 trend towards larger break radius with increasing cluster mass. Our SZ-based masses fall ˜16% below the mass-richness relations from weak lensing, in a similar fashion as the "hydrostatic bias" related with X-ray derived masses. Finally, we derive a tight Y500-M500 relation over a wide range of cluster mass, with a power law slope equal to 1.70 ± 0.07, that agrees well with the independent slope obtained by the Planck team with an SZ-selected cluster sample, but extends to lower masses with higher precision.

  8. Quantitative Thin-Layer Chromatography/Mass Spectrometry Analysis of Caffeine Using a Surface Sampling Probe Electrospray Ionization Tandem Mass Spectrometry System

    Energy Technology Data Exchange (ETDEWEB)

    Ford, Michael J [ORNL; Deibel, Michael A. [Earlham College; Tomkins, Bruce A [ORNL; Van Berkel, Gary J [ORNL

    2005-01-01

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 {mu}m/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 {mu}L) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by 8% or more) than the literature values.

  9. Use of gas chromatography-mass spectrometry for the assessment of the contamination caused by small concentrations of nitrophenols in soils and sediments

    Science.gov (United States)

    Cacho, Juan-Ignacio; Campillo, Natalia; Viñas, Pilar; Hernandez-Cordoba, Manuel

    2015-04-01

    Nitrophenols (NPs) are widely distributed environmental contaminants that can be present in soils and sediments due to the degradation of some pesticides (parathion and fenitrothion) or by accidental spilling in ammunition plants or storage places. This communication reports a rapid and sensitive procedure for the determination of the most common NPs in soils by using gas chromatography coupled to mass spectrometry (GC-MS) as the analytical technique. Ultrasound assisted extraction (UAE) was employed for the extraction of the NPs from the soil samples to an organic solvent. Next, the resulting UAE extracts were submitted to dispersive liquid-liquid microextraction (DLLME) for achieving an effective preconcentration. DLLME is an easy-to-carry out, environmentally friendly separation technique involving minimal amounts of organic solvents. Since the volatility of NPs is low, as a previous stage to the GC-MS measurement the compounds were derivatized using a simple "in-situ" acetylation procedure. The main parameters affecting the UAE stage, as well as the DLLME and derivatization steps, were investigated looking for maximum analytical signals. The optimized procedure provided extraction recoveries in the 72-86% range, with precision values (expressed as relative standard deviation, RSD) ≤ 12%, and detection limits ranging from 1.3 and 3.3 ng g-1, depending on the compound. 20 soil and sediment samples, from military, industrial and agricultural areas were analyzed by the studied procedure in order to check its applicability.

  10. Inductively coupled plasma mass spectrometry in the analysis of biological samples and pharmaceutical drugs

    Science.gov (United States)

    Ossipov, K.; Seregina, I. F.; Bolshov, M. A.

    2016-04-01

    Inductively coupled plasma mass spectrometry (ICP-MS) is widely used in the analysis of biological samples (whole blood, serum, blood plasma, urine, tissues, etc.) and pharmaceutical drugs. The shortcomings of this method related to spectral and non-spectral interferences are manifested in full measure in determination of the target analytes in these complex samples strongly differing in composition. The spectral interferences are caused by similarity of masses of the target component and sample matrix components. Non-spectral interferences are related to the influence of sample matrix components on the physicochemical processes taking place during formation and transportation of liquid sample aerosols into the plasma, on the value and spatial distribution of plasma temperature and on the transmission of the ion beam from the interface to mass spectrometer detector. The review is devoted to analysis of different mechanisms of appearance of non-spectral interferences and to ways for their minimization or elimination. Special attention is paid to the techniques of biological sample preparation, which largely determine the mechanisms of the influence of sample composition on the results of element determination. The ways of lowering non-spectral interferences by instrumental parameter tuning and application of internal standards are considered. The bibliography includes 189 references.

  11. Rod-shaped silica particles derivatized with elongated silver nanoparticles immobilized within mesopores

    Energy Technology Data Exchange (ETDEWEB)

    Mnasri, Najib [Institut Charles Gerhardt de Montpellier, CNRS UMR 5253, Université Montpellier, Place Eugène Bataillon, 34095 Montpellier Cedex 5 (France); Materials, Environment and Energy Laboratory (UR14ES26), Faculty of Science, University of Gafsa, 2112 Gafsa (Tunisia); Charnay, Clarence; Ménorval, Louis-Charles de [Institut Charles Gerhardt de Montpellier, CNRS UMR 5253, Université Montpellier, Place Eugène Bataillon, 34095 Montpellier Cedex 5 (France); Elaloui, Elimame [Materials, Environment and Energy Laboratory (UR14ES26), Faculty of Science, University of Gafsa, 2112 Gafsa (Tunisia); Zajac, Jerzy, E-mail: jerzy.zajac@umontpellier.fr [Institut Charles Gerhardt de Montpellier, CNRS UMR 5253, Université Montpellier, Place Eugène Bataillon, 34095 Montpellier Cedex 5 (France)

    2016-11-15

    Silver-derivatized silica particles possessing a non-spherical morphology and surface plasmon resonance properties have been achieved. Nanometer-sized silica rods with uniformly sized mesopore channels were prepared first making use of alkyltrimethyl ammonium surfactants as porogens and the 1:0.10 tetraethyl orthosilicate (TEOS) : 3-aminopropyltriethoxysilane (APTES) mixture as a silicon source. Silica rods were subsequently functionalized by introducing elongated silver nanoparticles within the intra-particle mesopores thanks to the AgNO{sub 3} reduction procedure based on the action of hemiaminal groups previously located on the mesopore walls. The textural and structural features of the samples were inferred from the combined characterization studies including SEM and TEM microscopy, nitrogen adsorption-desorption at 77 K, powder XRD in the small- and wide-angle region, as well as UV–visible spectroscopy. {sup 129}Xe NMR spectroscopy appeared particularly useful to obtain a correct information about the porous structure of rod-shaped silica particles and the silver incorporation within their intra-particle mesopores. - Highlights: • Mesoporous monodisperse submicron-sized silica rods were achieved. • Silver nanoparticles were located lengthwise within the intra-particle mesopores. • Textural and plasmonic properties of particles studied by {sup 129}Xe NMR and UV–Vis.

  12. Chromatographic determination of nanomolar cyanate concentrations in estuarine and sea waters by precolumn fluorescence derivatization.

    Science.gov (United States)

    Widner, Brittany; Mulholland, Margaret R; Mopper, Kenneth

    2013-07-16

    Recent studies suggest that cyanate (OCN(-)) is a potentially important source of reduced nitrogen (N) available to support the growth of aquatic microbes and, thus, may play a role in aquatic N cycling. However, aquatic OCN(-) distributions have not been previously described because of the lack of a suitable assay for measuring OCN(-) concentrations in natural waters. Previous methods were designed to quantify OCN(-) in aqueous samples with much higher reduced N concentrations (micromolar levels) than those likely to be found in natural waters (nanomolar levels). We have developed a method to quantify OCN(-) in dilute, saline environments. In the method described here, OCN(-) in aqueous solution reacts with 2-aminobenzoic acid to produce a highly fluorescent derivative, 2,4-quinazolinedione, which is then quantified using high performance liquid chromatography. Derivatization conditions were optimized to simultaneously minimize the reagent blank and maximize 2,4-quinazolinedione formation (>90% reaction yield) in estuarine and seawater matrices. A limit of detection (LOD) of 0.4 nM was achieved with only minor matrix effects. We applied this method to measure OCN(-) concentrations in estuarine and seawater samples from the Chesapeake Bay and coastal waters from the mid-Atlantic region. OCN(-) concentrations ranged from 0.9 to 41 nM. We determined that OCN(-) concentrations were stable in 0.2 μm filtered seawater samples stored at -80 °C for up to nine months.

  13. The measurement of mass spectrometric peak height ratio of helium isotope in trace samples

    International Nuclear Information System (INIS)

    Sun Mingliang

    1989-01-01

    An experiment study on the measurement of mass spectrometric peak height ratio of helium isotope in the trace gaseous sample is discussed by using the gas purification line designed by the authors and model VG-5400 static-vacuum noble gas mass spectrometer imported and air helium as a standard. The results show that the amount of He and Ne in natural gas sample is 99% after purification. When the amount of He in Mass Spectrometer is more than 4 x 10 -7 cm 3 STP, it's sensitivity remains stable, about 10 -4 A/cm 3 STP He and the precision of 3 He/ 4 He ratio within the following 17 days is 1.32%. The 'ABA' pattern and experiment condition in the measurement of mass spectrometric peak height ratio of He isotope are presented

  14. A convenient tool for gas derivatization using fine-needle capillary mounting for protein crystals

    International Nuclear Information System (INIS)

    Mizuno, Nobuhiro; Makino, Masatomo; Kumasaka, Takashi

    2013-01-01

    A convenient gas-derivatization tool for protein crystals is presented in combination with a fine-needle capillary and a gas-pressure regulator. Gas derivatization of protein crystals is useful not only to analyse gas-binding proteins but also to solve the phase problem of X-ray crystallography by using noble gases. However, the gas pressurization tools for these experiments are often elaborate and need to release the gas before flash-cooling. To simplify this step, a procedure using a fine-needle capillary to mount and flash-cool protein crystals under the pressurization of gases has been developed. After the crystals are picked up with the capillary, the capillary is sealed with an adhesive and then connected directly to a gas regulator. The quality of the diffraction data using this method is comparable with that of data from conventional pressurization procedures. The preparation of xenon-derivatives of hen egg-white lysozyme using this method was a success. In the derivatives, two new xenon binding sites were found and one of their sites vanished by releasing the gas. This observation shows the availability of flash-cooling under gas pressurization. This procedure is simple and useful for preparing gas-derivative crystals

  15. Standardization of methodology to derivatization and radiolabeling of the anti-CD20 monoclonal antibody from bifunctional chelator DOTA-NHS-Ester

    International Nuclear Information System (INIS)

    Massicano, Adriana V.F.; Akanji, Akinkunmi G.; Santos, Josefina S.; Pujatti, Priscilla B.; Couto, Renata M.; Massicano, Felipe; Araujo, Elaine Bortoleti de

    2009-01-01

    Lymphomas are cancers of the lymphatic system, being the most common the non-Hodgkin lymphoma (NHL). The Radioimmunotherapy (RIT), that increase the cytotoxic effect of monoclonal antibodies (mAb), therefore labeling these Mab with different radioisotopes. RIT combines the specificity of the antibody and the toxicity of the radionuclides. The mAb anti-CD20 is used for treatment of relapse or refractory NHL. The labeling of anti- CD20 with 177 Lu, requires a bifunctional chelating agent that is designed to make a 'connect bridge' between the mAb and the radionuclide. The incorporation of the chelating group in mAb structure is called derivatization. The aim of this work is to study the derivatization of anti-CD20 antibody with DOTA-NHS-ester chelating group and labeling parameters to produce 177 Lu-DOTA-Anti CD20. Five milligrams of anti-CD20 were purified by dialysis against phosphate buffer pH 8.0 and derivatized with DOTA-NHS-ester in 1:250, 1:500 and 1:1000 molar ratios. The reaction was conducted for 1 hour in gently mixing at room temperature and remained under refrigeration for 48 hours. The reaction mixture was purified in gel column Sephadex G-50 ; the aliquots that presented greater protein concentration, were mixed and concentrated. The purified antibody conjugated was added to 111-185MBq (3-5mCi) of 177 LuCl3 diluted in 0.4 M acetate buffer pH 5.5. Radiochemical purity was less than 95% in all the molar ratios, indicating necessity of the purification after the labeling. The mAb derivatized showed stable when stored for to 1 month to 4 deg C and 4 days at -20 deg C. (author)

  16. GC separation of amino acid enantiomers via derivatization with heptafluorobutyl chloroformate and Chirasil-L-Val column

    Czech Academy of Sciences Publication Activity Database

    Zahradníčková, Helena; Hušek, Petr; Šimek, Petr

    2009-01-01

    Roč. 32, č. 22 (2009), s. 3919-3924 ISSN 1615-9306 R&D Projects: GA ČR GA203/09/2014 Institutional research plan: CEZ:AV0Z50070508 Keywords : chiral separation * derivatization * D,L-AAs Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.551, year: 2009

  17. Derivatized Pentadentate Macrocyclic Ligands and Their Transition Metal Complexes

    Directory of Open Access Journals (Sweden)

    Muhammad S. Khan

    2002-06-01

    Full Text Available The reaction of the pendant hydroxyethyl group in the planar pentadentate macrocyclic ligand,1,11-bis(2’-hydroxyethyl-4,8;12,16;17,21-trinitrilo-1,2,10,11-tetraazacyclohenicosa- 2,4,6,9,12,14,18,20-octaene (L2, derived from the condensation of 2,6-pyridinedialdehyde with 6,6’-bis(2’ hydroxyethylhydrazino -2,2’-bipyridine (L1, has been investigated. Esterification reactions are facile, and the reaction of the hydroxyethyl-substituted macrocycle with thionyl chloride yields a chloroethyl derivative. Metal complexes of the new derivatized macrocyclic ligands L3-6having general formula ML3-6X2.nH2O (M = Mn, Fe, Co, Ni, Cu, Zn are readily prepared.

  18. Analysis of poly-beta-hydroxybutyrate in environmental samples by GC-MS/MS.

    Science.gov (United States)

    Elhottová, D; Tríska, J; Petersen, S O; Santrůcková, H

    2000-05-01

    Application of gas chromatography-mass spectrometry (GC-MS) can significantly improve trace analyses of compounds in complex matrices from natural environments compared to gas chromatography only. A GC-MS/MS technique for determination of poly-beta-hydroxybutyrate (PHB), a bacterial storage compound, has been developed and used for analysis of two soils stored for up to 319 d, fresh samples of sewage sludge, as well as a pure culture of Bacillus megaterium. Specific derivatization of beta-hydroxybutyrate (3-OH C4:0) PHB monomer units by N-tert-butyl-dimethylsilyl-N-methyltrifluoracetamide (MTBSTFA) improved chromatographic and mass spectrometric properties of the analyte. The diagnostic fragmentation scheme of the derivates tert-butyldimethylsilyl ester and ether of beta-hydroxybutyric acid (MTBSTFA-HB) essential for the PHB identification was shown. The ion trap MS was used, therefore the scan gave the best sensitivity and with MS/MS the noise decreased, so the S/N was better and also with second fragmentation the amount of ions increased compared to SIM. The detection limit for MTBSTFA-HB by GC-MS/MS was about 10(-13) g microL(-1) of injected volume, while by GC (FID) and GC-MS (scan) it was around 10(-10) g microL(-1) of injected volume. Sensitivity of GC-MS/MS measurements of PHB in arable soil and activated sludge samples was down to 10 pg of PHB g(-1) dry matter. Comparison of MTBSTFA-HB detection in natural soil sample by GC (FID), GC-MS (scan) and by GC-MS/MS demonstrated potentials and limitations of the individual measurement techniques.

  19. [Specific detection of urinary sympathomimetic amines for control of anti-doping by gas chromatography-mass spectroscopy].

    Science.gov (United States)

    Franceschini, A; Duthel, J M; Vallon, J J

    1991-03-22

    A specific, sensitive and reliable gas chromatography-mass spectrometry (GC-MS) technique for detection of sympathomimetic amines following urinary extraction is proposed. Amphetamine, phentermine, ephedrine, mephenorex, methylphenidate, benzphetamine, clobenzorex and internal standard (fenfluramine) are extracted from urines at pH 7.0 using elution by chloroform-isopropanol on C18 cartridges. Derivatization followed by GC-MS analysis allows identification of these drugs founded on relative retention times and mass spectra. The quantitation limit for derivatizable drugs was found to be 200 ng/ml and 500 ng/ml for underivatizable drugs.

  20. The analysis of uranium in environmental sample by mass spectrometer combined with isotopic dilution

    International Nuclear Information System (INIS)

    Fu Zhonghua; Jia Baoting; Han Jun

    2003-01-01

    Uranium in the environmental sample was analyzed by mass spectrometer combined with isotopic dilution. Before mass spectrometer analysis, samples were dissolved in a concentrated acidic solution containing HNO 3 , HF and HClO 4 and chemically processed to suit the analysis requirement. Analysis results indicated that the uranium content was 0.08 μg/g in river water, 0.1 μg/g in evergreen foliage, and 5-11 μg/g in surface soil respectively. (authors)

  1. A method for the determination of acrylamide in a broad variety of processed foods by GC-MS using xanthydrol derivatization.

    Science.gov (United States)

    Yamazaki, Kumiko; Isagawa, Satoshi; Kibune, Nobuyuki; Urushiyama, Tetsuo

    2012-01-01

    A novel GC-MS method was developed for the determination of acrylamide, which is applicable to a variety of processed foods, including potato snacks, corn snacks, biscuits, instant noodles, coffee, soy sauces and miso (fermented soy bean paste). The method involves the derivatization of acrylamide with xanthydrol instead of a bromine compound. Isotopically labelled acrylamide (d₃-acrylamide) was used as the internal standard. The aqueous extract from samples was purified using Sep-Pak™ C₁₈ and Sep-Pak™ AC-2 columns. For amino acid-rich samples, such as miso or soy sauce, an Extrelut™ column was used for purification or extraction. After reaction with xanthydrol, the resultant N-xanthyl acrylamide was determined by GC-MS. The method was validated for various food matrices and showed good linearity, precision and trueness. The limit of detection and limit of quantification ranged 0.5-5 and 5-20 µg kg⁻¹), respectively. The developed method was applied as an exploratory survey of acrylamide in Japanese foods and the method was shown to be applicable for all samples tested.

  2. High-throughput analysis of amino acids in plant materials by single quadrupole mass spectrometry

    DEFF Research Database (Denmark)

    Dahl-Lassen, Rasmus; van Hecke, Jan Julien Josef; Jørgensen, Henning

    2018-01-01

    that it is very time consuming with typical chromatographic run times of 70 min or more. Results: We have here developed a high-throughput method for analysis of amino acid profiles in plant materials. The method combines classical protein hydrolysis and derivatization with fast separation by UHPLC and detection...... reducing the overall analytical costs compared to methods based on more advanced mass spectrometers....... by a single quadrupole (QDa) mass spectrometer. The chromatographic run time is reduced to 10 min and the precision, accuracy and sensitivity of the method are in line with other recent methods utilizing advanced and more expensive mass spectrometers. The sensitivity of the method is at least a factor 10...

  3. Direct sampling of chemical weapons in water by photoionization mass spectrometry.

    Science.gov (United States)

    Syage, Jack A; Cai, Sheng-Suan; Li, Jianwei; Evans, Matthew D

    2006-05-01

    The vulnerability of water supplies to toxic contamination calls for fast and effective means for screening water samples for multiple threats. We describe the use of photoionization (PI) mass spectrometry (MS) for high-speed, high-throughput screening and molecular identification of chemical weapons (CW) threats and other hazardous compounds. The screening technology can detect a wide range of compounds at subacute concentrations with no sample preparation and a sampling cycle time of approximately 45 s. The technology was tested with CW agents VX, GA, GB, GD, GF, HD, HN1, and HN3, in addition to riot agents and precursors. All are sensitively detected and give simple PI mass spectra dominated by the parent ion. The target application of the PI MS method is as a routine, real-time early warning system for CW agents and other hazardous compounds in air and in water. In this work, we also present comprehensive measurements for water analysis and report on the system detection limits, linearity, quantitation accuracy, and false positive (FP) and false negative rates for concentrations at subacute levels. The latter data are presented in the form of receiver operating characteristic curves of the form of detection probability P(D) versus FP probability P(FP). These measurements were made using the CW surrogate compounds, DMMP, DEMP, DEEP, and DIMP. Method detection limits (3sigma) obtained using a capillary injection method yielded 1, 6, 3, and 2 ng/mL, respectively. These results were obtained using 1-microL injections of water samples without any preparation, corresponding to mass detection limits of 1, 6, 3, and 2 pg, respectively. The linear range was about 3-4 decades and the dynamic range about 4-5 decades. The relative standard deviations were generally <10% at CW subacute concentrations levels.

  4. Reduction of Martian Sample Return Mission Launch Mass with Solar Sail Propulsion

    Science.gov (United States)

    Russell, Tiffany E.; Heaton, Andrew; Thomas, Scott; Thomas, Dan; Young, Roy; Baysinger, Mike; Capizzo, Pete; Fabisinski, Leo; Hornsby, Linda; Maples, Dauphne; hide

    2013-01-01

    Solar sails have the potential to provide mass and cost savings for spacecraft traveling within the inner solar system. Companies like L'Garde have demonstrated sail manufacturability and various in-space deployment methods. The purpose of this study was to evaluate a current Mars sample return architecture and to determine how cost and mass would be reduced by incorporating a solar sail propulsion system. The team validated the design proposed by L'Garde, and scaled the design based on a trajectory analysis. Using the solar sail design reduced the required mass, eliminating one of the three launches required in the original architecture.

  5. Continuous determination of gaseous ammonia in the ambient atmosphere using fluorescence derivatization

    Science.gov (United States)

    Abbas, Rana; Tanner, Roger L.

    A method for continuous determination of ambient ammonia levels employing o-phthalaldehyde fluorescence derivatization is described. A simplified Venturi scrubber and gas-liquid separator have been employed for reproducible measurements of ⩾ 0.1 ppb ambient ammonia with less than 2 min time resolution. The scrubbing efficiency of the ammonia gas collection system was determined to be 29 ± 1 %. During 4 d in August 1979 ambient ammonia levels at the Brookhaven National Laboratory site averaged about 1.5 ± 1.1 ppb during afternoon daylight hours.

  6. Analysis of Selected Carbonyl Compounds in Tobacco Samples by Using Pentafluorobenzylhydroxylamine Derivatization and Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Bao Mingliang

    2014-09-01

    Full Text Available Nous avons mis au point une méthode, à la fois fiable, précise et simple, d’analyse courante des composés carbonylés, en ce compris le formaldéhyde, l’acétaldéhyde, l’acétone, le propionaldéhyde, la méthyléthylcétone (MEC, le butyraldéhyde et le crotonaldéhyde, présents à l’état de traces dans les produits de tabac ouvré. Un échantillon d’un gramme de tabac, additionné d’un mélange de carbonyles marqués d’un isotope en guise de normes internes, a été extrait par l’eau. Une part de l’extrait aqueux a subi un processus de dérivatisation à l’aide de chlorhydrate d’o-(2,3,4,5,6-pentafluorobenzyle-hydroxylamine (PFBHA. Les dérivés carbonylés obtenus à l’aide du PFBHA ont ensuite été extraits par l’hexane et analysés par chromatographie en phase gazeuse couplée à la spectrométrie de masse (GC-MS. La précision et l’exactitude de la méthode ont été évaluées au regard d’une cigarette de référence Kentucky « additionnée » 3R4F et de produits de référence sans fumée CORESTA CRP1, CRP2, CRP3 et CRP4. Eu égard aux composés carbonylés analysés, d’excellents taux de précision (5-10% et de récupération (95-107% ont été observés avec divers produits du tabac « additionnés », à l’exception de l’acroléine, qui s’est avérée instable dans tous les produits du tabac testés. L’intervalle linéaire de la méthode mise au point s’est étendu de 0,07 à 36 μg/g avec des limites de quantification variant de 0,10 à 0,15 μg/g. Grâce à la présente méthode, le formaldéhyde (0,31-6,24 μg/g et l’acétaldéhyde (0,84- 17,7 μg/g ont été décelés dans tous les produits de référence testés. L’acétone (0,55-2,12 μg/g a été trouvée dans les produits 3R4F, CRP1, CRP2 et CRP3. Des niveaux décelables de propionaldéhyde n’ont été observés que dans les produits CRP1 et CRP3. Les niveaux de MEC, butyraldéhyde et crotonaldéhyde décelés dans tous

  7. The analysis study of plutonium in the environmental sample by mass spectrum combined with isotopic dilution

    International Nuclear Information System (INIS)

    Han Jun; Fu Zhonghua; Mao Xingen; Meng Fanben

    2004-01-01

    The technology of the rhenium filament carbonization was used to increase the ionization efficiency in this paper. The plutonium in the environmental sample was analyzed by Mass Spectrum combined with isotope dilution. Analysis of the 239 Pu blank in the process: The analysis of 239 Pu from the chemical process was carried out in order to establish the influence of the 239 Pu introduced from the process. The analysis results were shown in Table 1 sample 1 was not gone through the process, sample 2 and sample 3 were gone through the process. It was clear that there was no influence of the 239 Pu from the process within the deviation. Results and Discussions: The environmental samples which were dealed with the chemical method were prepared the sample of mass spectrum, The atomic ratio of the 239 Pu and 242 Pu in the environmental samples was measured by Mass Spectrum. The atomic ratio in the tracer 242 Pu was 0.01476±0.00007.The results for nuclide content in environment were given in Table 2. The content of 239 Pu in the tracer was high, so the existing of 239 Pu in the environmental samples can be determined by the changing of the atomic ratio of 242 Pu to 239 Pu. It was clear that there was 239 Pu in the environmental samples except the cypress leaves-2 and the pine leaves-3 within the deviation, and the content of 239 Pu were given in Table 2. Conclusion: a. Plutonium was separated and purified from the impurity by the anion-exchange and the electrodeposition, it was possible to provide the eligible mass spectrum sample. b. The measurement of plutonium in the environmental samples was not influenced by the flow of the background in the experiment. c. As the technology of the rhenium carbonization was used to increase the ionization efficiency, the content of plutonium which was about 10 -13 g in the environmental sample could be quantitatively analyzed by Mass Spectrum combined with isotope dilution. (authors)

  8. Recent contributions of flame-sampling molecular-beam mass spectrometry to a fundamental understanding of combustion chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Nils [Combustion Research Facility, Sandia National Laboratories, Livermore, CA 94551 (United States); Cool, Terrill A. [School of Applied and Engineering Physics, Cornell University, Ithaca, NY 14853 (United States); Westmoreland, Phillip R. [Department of Chemical Engineering, University of Massachusetts, Amherst, MA 01003 (United States); Kohse-Hoeinghaus, Katharina [Department of Chemistry, Bielefeld University, D-33615 Bielefeld (Germany)

    2009-04-15

    Flame-sampling molecular-beam mass spectrometry of premixed, laminar, low-pressure flat flames has been demonstrated to be an efficient tool to study combustion chemistry. In this technique, flame gases are sampled through a small opening in a quartz probe, and after formation of a molecular beam, all flame species are separated using mass spectrometry. The present review focuses on critical aspects of the experimental approach including probe sampling effects, different ionization processes, and mass separation procedures. The capability for isomer-resolved flame species measurements, achievable by employing tunable vacuum-ultraviolet radiation for single-photon ionization, has greatly benefited flame-sampling molecular-beam mass spectrometry. This review also offers an overview of recent combustion chemistry studies of flames fueled by hydrocarbons and oxygenates. The identity of a variety of intermediates in hydrocarbon flames, including resonantly stabilized radicals and closed-shell intermediates, is described, thus establishing a more detailed understanding of the fundamentals of molecular-weight growth processes. Finally, molecular-beam mass-spectrometric studies of reaction paths in flames of alcohols, ethers, and esters, which have been performed to support the development and validation of kinetic models for bio-derived alternative fuels, are reviewed. (author)

  9. Determination of amphetamine-type stimulants in oral fluid by solid-phase microextraction and gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Daniele Z., E-mail: daniele.dzs@dpf.gov.br [Setor Tecnico-Cientifico, Superintendencia Regional do Departamento de Policia Federal no Rio Grande do Sul, 1365 Ipiranga Avenue, Azenha, Zip Code 90160-093 Porto Alegre, Rio Grande do Sul (Brazil); Programa de Pos-Graduacao em Ciencias Farmaceuticas, Faculdade de Farmacia, Universidade Federal do Rio Grande do Sul, 2752 Ipiranga Avenue, Santana, Zip Code 90610-000 Porto Alegre, Rio Grande do Sul (Brazil); Boehl, Paula O.; Comiran, Eloisa; Mariotti, Kristiane C. [Programa de Pos-Graduacao em Ciencias Farmaceuticas, Faculdade de Farmacia, Universidade Federal do Rio Grande do Sul, 2752 Ipiranga Avenue, Santana, Zip Code 90610-000 Porto Alegre, Rio Grande do Sul (Brazil); Pechansky, Flavio [Centro de Pesquisa em Alcool e Drogas (CPAD), Hospital de Clinicas de Porto Alegre, Universidade Federal do Rio Grande do Sul, 2350, Ramiro Barcelos Street, Zip Code 90035-903 Porto Alegre, Rio Grande do Sul (Brazil); Duarte, Paulina C.A.V. [Secretaria Nacional de Politicas sobre Drogas (SENAD), Esplanada dos Ministerios, Block ' A' , 5th floor, Zip Code 70050-907 Brasilia, Distrito Federal (Brazil); De Boni, Raquel [Centro de Pesquisa em Alcool e Drogas (CPAD), Hospital de Clinicas de Porto Alegre, Universidade Federal do Rio Grande do Sul, 2350, Ramiro Barcelos Street, Zip Code 90035-903 Porto Alegre, Rio Grande do Sul (Brazil); Froehlich, Pedro E.; Limberger, Renata P. [Programa de Pos-Graduacao em Ciencias Farmaceuticas, Faculdade de Farmacia, Universidade Federal do Rio Grande do Sul, 2752 Ipiranga Avenue, Santana, Zip Code 90610-000 Porto Alegre, Rio Grande do Sul (Brazil)

    2011-06-24

    Graphical abstract: Highlights: > Propylchloroformate derivatization of amphetamine-type stimulants in oral fluid. > Direct immersion solid-phase microextraction/gas chromatography-mass spectrometry. > Linear range 2(4)-256 ng mL{sup -1}, detection limits 0.5-2 ng mL{sup -1}. > Accuracy 98-112%, precision <15% of RSD, recovery 77-112%. > Importance of residual evaluation in checking model goodness-of-fit. - Abstract: A method for the simultaneous identification and quantification of amphetamine (AMP), methamphetamine (MET), fenproporex (FEN), diethylpropion (DIE) and methylphenidate (MPH) in oral fluid collected with Quantisal{sup TM} device has been developed and validated. Thereunto, in-matrix propylchloroformate derivatization followed by direct immersion solid-phase microextraction and gas chromatography-mass spectrometry were employed. Deuterium labeled AMP was used as internal standard for all the stimulants and analysis was performed using the selected ion monitoring mode. The detector response was linear for the studied drugs in the concentration range of 2-256 ng mL{sup -1} (neat oral fluid), except for FEN, whereas the linear range was 4-256 ng mL{sup -1}. The detection limits were 0.5 ng mL{sup -1} (MET), 1 ng mL{sup -1} (MPH) and 2 ng mL{sup -1} (DIE, AMP, FEN), respectively. Accuracy of quality control samples remained within 98.2-111.9% of the target concentrations, while precision has not exceeded 15% of the relative standard deviation. Recoveries with Quantisal{sup TM} device ranged from 77.2% to 112.1%. Also, the goodness-of-fit concerning the ordinary least squares model in the statistical inference of data has been tested through residual plotting and ANOVA. The validated method can be easily automated and then used for screening and confirmation of amphetamine-type stimulants in drivers' oral fluid.

  10. Small sample analysis using sputter atomization/resonance ionization mass spectrometry

    International Nuclear Information System (INIS)

    Christie, W.H.; Goeringer, D.E.

    1986-01-01

    We have used secondary ion mass spectrometry (SIMS) to investigate the emission of ions via argon sputtering from U metal, UO 2 , and U 3 O 8 samples. We have also used laser resonance ionization techniques to study argon-sputtered neutral atoms and molecules emitted from these same samples. For the case of U metal, a significant enhancement in detection sensitivity for U is obtained via SA/RIMS. For U in the fully oxidized form (U 3 O 8 ), SA/RIMS offers no improvement in U detection sensitivity over conventional SIMS when sputtering with argon. 9 refs., 1 fig., 2 tabs

  11. Determination of post-culture processing with carbohydrates by MALDI-MS and TMS derivatization GC-MS.

    Science.gov (United States)

    Wunschel, David S; Wahl, Karen L; Melville, Angela M; Sorensen, Christina M; Colburn, Heather A; Valentine, Nancy B; Stamper, Casey L

    2011-10-15

    Biological materials generally require stabilization to retain activity or viability in a dry form. A number of industrial products, such as vaccines, probiotics and biopesticides have been produced as dry preparations. The same methods and materials used for stabilizing commercial microbial products may be applicable to preserving biothreat pathogens in a dry form. This is a likely step that may be encountered when looking at samples from terrorism attempts since only spores, such as those from Bacillus anthracis, are inherently stable when dried. The stabilizers for microbial preparations generally include one or more small carbohydrates. Different formulations have been reported for different industrial products and are often determined empirically. However sugar alcohols (mannitol and sorbitol) and disaccharides (lactose, sucrose and trehalose) are the common constituents of these formulations. We have developed an analytical method for sample preparation and detection of these simple carbohydrates using two complementary analytical tools, MALDI-MS and GC-MS. The native carbohydrates and other constituents of the formulation are detected by MALDI-MS as a screening tool. A longer and more detailed analysis is then used to specifically identify the carbohydrates by derivatization and GC-MS detection. Both techniques were tested against ten different types of stabilization recipes with Yersinia pestis cell mass cultured on different media types used as the biological component. A number of additional components were included in these formulations including proteins and peptides from serum or milk, polymers (e.g. poly vinyl pyrrolidone - PVP) and detergents (e.g. Tween). The combined method was characterized to determine several figures of merit. The accuracy of the method was 98% for MALDI-MS and 100% for GC-MS. The repeatability for detection of carbohydrates by MALDI-MS was determined to be 96%. The repeatability of compound identification by GC-MS was

  12. High-performance liquid chromatography/electrospray mass spectrometry for the analysis of modified bases in DNA: 7-(2-hydroxyethyl)guanine, the major ethylene oxide-DNA adduct.

    Science.gov (United States)

    Leclercq, L; Laurent, C; De Pauw, E

    1997-05-15

    A method was developed for the analysis of 7-(2-hydroxyethyl)guanine (7HEG), the major DNA adduct formed after exposure to ethylene oxide (EO). The method is based on DNA neutral thermal hydrolysis, adduct micro-concentration, and final characterization and quantification by HPLC coupled to single-ion monitoring electrospray mass spectrometry (HPLC/SIR-ESMS). The method was found to be selective, sensitive, and easy to handle with no need for enzymatic digestion or previous sample derivatization. Detection limit was found to be close to 1 fmol of adduct injected (10(-10) M), thus allowing the detection of approximately three modified bases on 10(8) intact nucleotides in blood sample analysis. Quantification results are shown for 7HEG after calf thymus DNA and blood exposure to various doses of EO, in both cases obtaining clear dose-response relationships.

  13. Determination of ruthenium in photographic emulsions - Development and comparison of different sample treatments and mass spectrometric methods

    NARCIS (Netherlands)

    Krystek, Petra; Heumann, Klaus G.

    1999-01-01

    Different sample treatment procedures were combined with inductively coupled plasma mass spectrometry (ICP-MS) and negative thermal ionisation mass spectrometry (NTI-MS) for the determination of ruthenium traces in photographic emulsions. Dissolution of the samples in concentrated ammonia solution

  14. Implementation of the method of detection of cocaine, opiates and their metabolites in hair by gas chromatography coupled to mass spectrometry

    International Nuclear Information System (INIS)

    Fallas Monge, Lilliana; Lopez Chacon, Jose Miguel

    2009-01-01

    A derivatization and optimized chromatographic method was developed to be used in routine analysis of samples. Three derivatizing were tested: propionic anhydride, HFBA and BSTFA. The BSTFA is what has given better results allowing the derivatization of all analytes of interest with a fragmentation pattern suitable for GC-MS analysis. The propyl benzoylecgonine and cocaine-D3 for cocaine and opiates nalorphine have been used as internal standards. A chromatographic method that had resolutions > 1.5 have been optimized between the chromatographic peaks of each analyte in a time of 12 minutes. The repeatability in the optimization of the method developed has been discussed in several variables: the relative standard deviation (RSD) for the areas has been 2 higher than 0.9974 and obtained a minimum LOD of 0.2 ng (6-MAN and BE) and a maximum of 5 ng (HE and ME). (author) [es

  15. The volatile compound BinBase mass spectral database.

    Science.gov (United States)

    Skogerson, Kirsten; Wohlgemuth, Gert; Barupal, Dinesh K; Fiehn, Oliver

    2011-08-04

    Volatile compounds comprise diverse chemical groups with wide-ranging sources and functions. These compounds originate from major pathways of secondary metabolism in many organisms and play essential roles in chemical ecology in both plant and animal kingdoms. In past decades, sampling methods and instrumentation for the analysis of complex volatile mixtures have improved; however, design and implementation of database tools to process and store the complex datasets have lagged behind. The volatile compound BinBase (vocBinBase) is an automated peak annotation and database system developed for the analysis of GC-TOF-MS data derived from complex volatile mixtures. The vocBinBase DB is an extension of the previously reported metabolite BinBase software developed to track and identify derivatized metabolites. The BinBase algorithm uses deconvoluted spectra and peak metadata (retention index, unique ion, spectral similarity, peak signal-to-noise ratio, and peak purity) from the Leco ChromaTOF software, and annotates peaks using a multi-tiered filtering system with stringent thresholds. The vocBinBase algorithm assigns the identity of compounds existing in the database. Volatile compound assignments are supported by the Adams mass spectral-retention index library, which contains over 2,000 plant-derived volatile compounds. Novel molecules that are not found within vocBinBase are automatically added using strict mass spectral and experimental criteria. Users obtain fully annotated data sheets with quantitative information for all volatile compounds for studies that may consist of thousands of chromatograms. The vocBinBase database may also be queried across different studies, comprising currently 1,537 unique mass spectra generated from 1.7 million deconvoluted mass spectra of 3,435 samples (18 species). Mass spectra with retention indices and volatile profiles are available as free download under the CC-BY agreement (http://vocbinbase.fiehnlab.ucdavis.edu). The Bin

  16. The volatile compound BinBase mass spectral database

    Directory of Open Access Journals (Sweden)

    Barupal Dinesh K

    2011-08-01

    Full Text Available Abstract Background Volatile compounds comprise diverse chemical groups with wide-ranging sources and functions. These compounds originate from major pathways of secondary metabolism in many organisms and play essential roles in chemical ecology in both plant and animal kingdoms. In past decades, sampling methods and instrumentation for the analysis of complex volatile mixtures have improved; however, design and implementation of database tools to process and store the complex datasets have lagged behind. Description The volatile compound BinBase (vocBinBase is an automated peak annotation and database system developed for the analysis of GC-TOF-MS data derived from complex volatile mixtures. The vocBinBase DB is an extension of the previously reported metabolite BinBase software developed to track and identify derivatized metabolites. The BinBase algorithm uses deconvoluted spectra and peak metadata (retention index, unique ion, spectral similarity, peak signal-to-noise ratio, and peak purity from the Leco ChromaTOF software, and annotates peaks using a multi-tiered filtering system with stringent thresholds. The vocBinBase algorithm assigns the identity of compounds existing in the database. Volatile compound assignments are supported by the Adams mass spectral-retention index library, which contains over 2,000 plant-derived volatile compounds. Novel molecules that are not found within vocBinBase are automatically added using strict mass spectral and experimental criteria. Users obtain fully annotated data sheets with quantitative information for all volatile compounds for studies that may consist of thousands of chromatograms. The vocBinBase database may also be queried across different studies, comprising currently 1,537 unique mass spectra generated from 1.7 million deconvoluted mass spectra of 3,435 samples (18 species. Mass spectra with retention indices and volatile profiles are available as free download under the CC-BY agreement (http

  17. Significant enhancement of 11-Hydroxy-THC detection by formation of picolinic acid esters and application of liquid chromatography/multi stage mass spectrometry (LC-MS(3) ): Application to hair and oral fluid analysis.

    Science.gov (United States)

    Thieme, Detlef; Sachs, Ulf; Sachs, Hans; Moore, Christine

    2015-07-01

    Formation of picolinic acid esters of hydroxylated drugs or their biotransformation products is a promising tool to improve their mass spectrometric ionization efficiency, alter their fragmentation behaviour and enhance sensitivity and specificity of their detection. The procedure was optimized and tested for the detection of cannabinoids, which proved to be most challenging when dealing with alternative specimens, for example hair and oral fluid. In particular, the detection of the THC metabolites hydroxyl-THC and carboxy-THC requires ultimate sensitivity because of their poor incorporation into hair or saliva. Both biotransformation products are widely accepted as incorporation markers to distinguish drug consumption from passive contamination. The derivatization procedure was carried out by adding a mixture of picolinic acid, 4-(dimethylamino)pyridine and 2-methyl-6-nitrobenzoic anhydride in tetrahydrofuran/triethylamine to the dry extraction residues. Resulting derivatives were found to be very stable and could be reconstituted in aqueous or organic buffers and subsequently analyzed by liquid chromatography-mass spectrometry (LC-MS). Owing to the complex consecutive fragmentation patterns, the application of multistage MS3 proved to be extremely useful for a sensitive identification of doubly picolinated hydroxy-THC in complex matrices. The detection limits - estimated by comparison of corresponding signal-to-noise ratios - increased by a factor of 100 following picolination. All other species examined, like cannabinol, THC, cannabidiol, and carboxy-THC, could also be derivatized exhibiting only moderate sensitivity improvements. The assay was systematically tested using hair samples and exemplarily applied to oral fluid. Concentrations of OH-THC identified in THC-positive hair samples ranged from 0.02 to 0.29pg/mg. Copyright © 2014 John Wiley & Sons, Ltd.

  18. Sample Preparation of Corn Seed Tissue to Prevent Analyte Relocations for Mass Spectrometry Imaging

    Science.gov (United States)

    Kim, Shin Hye; Kim, Jeongkwon; Lee, Young Jin; Lee, Tae Geol; Yoon, Sohee

    2017-08-01

    Corn seed tissue sections were prepared by the tape support method using an adhesive tape, and mass spectrometry imaging (MSI) was performed. The effect of heat generated during sample preparation was investigated by time-of-flight secondary mass spectrometry (TOF-SIMS) imaging of corn seed tissue prepared by the tape support and the thaw-mounted methods. Unlike thaw-mounted sample preparation, the tape support method does not cause imaging distortion because of the absence of heat, which can cause migration of the analytes on the sample. By applying the tape-support method, the corn seed tissue was prepared without structural damage and MSI with accurate spatial information of analytes was successfully performed.

  19. Sample Preparation of Corn Seed Tissue to Prevent Analyte Relocations for Mass Spectrometry Imaging.

    Science.gov (United States)

    Kim, Shin Hye; Kim, Jeongkwon; Lee, Young Jin; Lee, Tae Geol; Yoon, Sohee

    2017-08-01

    Corn seed tissue sections were prepared by the tape support method using an adhesive tape, and mass spectrometry imaging (MSI) was performed. The effect of heat generated during sample preparation was investigated by time-of-flight secondary mass spectrometry (TOF-SIMS) imaging of corn seed tissue prepared by the tape support and the thaw-mounted methods. Unlike thaw-mounted sample preparation, the tape support method does not cause imaging distortion because of the absence of heat, which can cause migration of the analytes on the sample. By applying the tape-support method, the corn seed tissue was prepared without structural damage and MSI with accurate spatial information of analytes was successfully performed. Graphical Abstract ᅟ.

  20. Determination of the Isotope Ratio for Metal Samples Using a Laser Ablation/Ionization Time-of-flight Mass Spectrometry

    International Nuclear Information System (INIS)

    Song, Kyu Seok; Cha, Hyung Ki; Kim, Duk Hyeon; Min, Ki Hyun

    2004-01-01

    The laser ablation/ionization time-of-flight mass spectrometry is applied to the isotopic analysis of solid samples using a home-made instrument. The technique is convenient for solid sample analysis due to the onestep process of vaporization and ionization of the samples. The analyzed samples were lead, cadmium, molybdenum, and ytterbium. To optimize the analytical conditions of the technique, several parameters, such as laser energy, laser wavelength, size of the laser beam on the samples surface, and high voltages applied on the ion source electrodes were varied. Low energy of laser light was necessary to obtain the optimal mass resolution of spectra. The 532 nm light generated mass spectra with the higher signal-to-noise ratio compared with the 355 nm light. The best mass resolution obtained in the present study is ∼1,500 for the ytterbium

  1. Applications of free-jet, molecular beam, mass spectrometric sampling: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Milne, T. [ed.

    1995-03-01

    Over the past 35 years, the study of die behavior and uses of free-jet expansions for laboratory experiments has greatly expanded and matured. Not the least of these uses of free-jet expansions, is that of extractive sampling from high temperature, reactive systems. The conversion of the free-jet expanded gases to molecular flow for direct introduction into the ion source of a mass spectrometer offers several advantages, to be illustrated in these pages. Two meetings on this subject were held in 1965 and 1972 in Missouri, sponsored by the Office of Naval Research and Midwest Research Institute. At these meetings rarefied gas dynamicists came together with scientists using free-jet sampling for analytical purposes. After much too long a time, this workshop was convened to bring together modem practitioners of FJMBS (Free-jet, Molecular-beam, mass spectrometry) and long time students of the free-jet process itself, to assess the current state of the art and to forge a community that can foster the development of this novel analytical approach. This proceedings is comprised of 38 individually submitted papers. Individual papers are indexed separately on the Energy Data Base.

  2. A new method for immediate derivatization of hydroxyl groups by fluoroalkyl chloroformates and its application for the determination of sterols and tocopherols in human serum and amniotic fluid by gas chromatography-mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Řimnáčová, Lucie; Hušek, Petr; Šimek, Petr

    2014-01-01

    Roč. 1339, APR 25 (2014), s. 154-167 ISSN 0021-9673 R&D Projects: GA MZd(CZ) NT11513 Grant - others:Czech Science Foundation(CZ) P206-10-2401; Grant Agency of Charles University(CZ) 54009 Institutional support: RVO:60077344 Keywords : alkyl chlorformate derivatization * steroid hydroxyl group * liquid-liquid microextraction Subject RIV: CB - Analytical Chemistry , Separation Impact factor: 4.169, year: 2014 http://www.sciencedirect.com/science/article/pii/S0021967314003707

  3. Quantitative Caffeine Analysis Using a Surface Sampling Probe Electrospray Ionization Tandem Mass Spectrometry System

    Energy Technology Data Exchange (ETDEWEB)

    Ford, Michael J [ORNL; Deibel, Michael A. [Earlham College; Tomkins, Bruce A [ORNL; Van Berkel, Gary J [ORNL

    2005-01-01

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 {mu}m/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 {mu}L) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by 8% or more) than the literature values.

  4. 1,5-Anhydro-D-fructose: biocatalytic and chemical synthetic methods for the preparation, transformation and derivatization

    DEFF Research Database (Denmark)

    Lundt, Inge; Yu, Shukun

    2010-01-01

    1,5-Anhydro-D-fructose (1,5AnFru) is a monoketosaccharide that can be prepared enzymatically from starch by a-1,4-glucan lyase or chemically from D-glucose or D-fructose in a few steps with high yields. The formed 1,5AnFru can be derivatized both enzymatically and chemically to interesting new...

  5. A Stability-Indicating HPLC Method for the Determination of Memantine Hydrochloride in Dosage Forms through Derivatization with 1-Fluoro-2,4-dinitrobenzene

    Science.gov (United States)

    Jalalizadeh, Hassan; Raei, Mahdi; Tafti, Razieh Fallah; Farsam, Hassan; Kebriaeezadeh, Abbas; Souri, Effat

    2014-01-01

    Memantine is chemically a tricyclic amine and is used for Parkinson’s disease and movement disorders. Although several HPLC methods with different derivatization reagents have been developed for the determination of memantine in biological fluids, there are some complications which limit the use of these methods in routine analysis of memantine in in vitro tests. We established a simple, sensitive, precise, and accurate HPLC method for the quantification of memantine in dosage forms. Pre-column derivatization of memantine was performed with 1-fluoro-2,4-dinitrobenzene and the reaction product was separated on a Nova-Pak C18 column. A mixture of acetonitrile and sodium dihydrogenphosphate (pH 2.5; 0.05 M) (70: 30, v/v) was used as the mobile phase. UV detection was performed at 360 nm. Forced degradation studies were performed on a powdered tablet sample of memantine hydro-chloride using acidic (0.1 M hydrochloric acid), basic (0.1 M sodium hydroxide), oxidative (10% hydrogen peroxide), thermal (105°C), photolytic, and humidity conditions. Good linearity (r2=0.999) was obtained over the range of 1–12 μg mL−1 of memantine hydrochloride with acceptable within-day and between-day precision values in the range of 0.05–0.95%. The proposed method was used for the assay determination and dissolution rate study of memantine dosage forms with excellent specificity. PMID:24959398

  6. Low-mass molecular dynamics simulation: A simple and generic technique to enhance configurational sampling

    Energy Technology Data Exchange (ETDEWEB)

    Pang, Yuan-Ping, E-mail: pang@mayo.edu

    2014-09-26

    Highlights: • Reducing atomic masses by 10-fold vastly improves sampling in MD simulations. • CLN025 folded in 4 of 10 × 0.5-μs MD simulations when masses were reduced by 10-fold. • CLN025 folded as early as 96.2 ns in 1 of the 4 simulations that captured folding. • CLN025 did not fold in 10 × 0.5-μs MD simulations when standard masses were used. • Low-mass MD simulation is a simple and generic sampling enhancement technique. - Abstract: CLN025 is one of the smallest fast-folding proteins. Until now it has not been reported that CLN025 can autonomously fold to its native conformation in a classical, all-atom, and isothermal–isobaric molecular dynamics (MD) simulation. This article reports the autonomous and repeated folding of CLN025 from a fully extended backbone conformation to its native conformation in explicit solvent in multiple 500-ns MD simulations at 277 K and 1 atm with the first folding event occurring as early as 66.1 ns. These simulations were accomplished by using AMBER forcefield derivatives with atomic masses reduced by 10-fold on Apple Mac Pros. By contrast, no folding event was observed when the simulations were repeated using the original AMBER forcefields of FF12SB and FF14SB. The results demonstrate that low-mass MD simulation is a simple and generic technique to enhance configurational sampling. This technique may propel autonomous folding of a wide range of miniature proteins in classical, all-atom, and isothermal–isobaric MD simulations performed on commodity computers—an important step forward in quantitative biology.

  7. Imaging mass spectrometry and genome mining reveal highly antifungal virulence factor of mushroom soft rot pathogen.

    Science.gov (United States)

    Graupner, Katharina; Scherlach, Kirstin; Bretschneider, Tom; Lackner, Gerald; Roth, Martin; Gross, Harald; Hertweck, Christian

    2012-12-21

    Caught in the act: imaging mass spectrometry of a button mushroom infected with the soft rot pathogen Janthinobacterium agaricidamnosum in conjunction with genome mining revealed jagaricin as a highly antifungal virulence factor that is not produced under standard cultivation conditions. The structure of jagaricin was rigorously elucidated by a combination of physicochemical analyses, chemical derivatization, and bioinformatics. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Determination of acrylamide in Chinese traditional carbohydrate-rich foods using gas chromatography with micro-electron capture detector and isotope dilution liquid chromatography combined with electrospray ionization tandem mass spectrometry

    International Nuclear Information System (INIS)

    Zhang Yu; Ren Yiping; Zhao Hangmei; Zhang Ying

    2007-01-01

    The present study developed two analytical methods for quantification of acrylamide in complex food matrixes, such as Chinese traditional carbohydrate-rich foods. One is based on derivatization with potassium bromate and potassium bromide without clean-up prior to gas chromatography with micro-electron capture detector (GC-MECD). Alternatively, the underivatized acrylamide was detected by high-performance liquid chromatography coupled to quadrupole tandem mass spectrometry (HPLC-MS/MS) in the positive electrospray ionization mode. For both methods, the Chinese carbohydrate-rich samples were homogenized, defatted with petroleum ether and extracted with aqueous solution of sodium chloride. Recovery rates for acrylamide from spiked Chinese style foods with the spiking level of 50, 500 and 1000 μg kg -1 were in the range of 79-93% for the GC-MECD including derivatization and 84-97% for the HPLC-MS/MS method. Typical quantification limits of the HPLC-MSMS method were 4 μg kg -1 for acrylamide. The GC-MECD method achieved quantification limits of 10 μg kg -1 in Chinese style foods. Thirty-eight Chinese traditional foods purchased from different manufacturers were analyzed and compared with four Western style foods. Acrylamide contaminant was found in all of samples at the concentration up to 771.1 and 734.5 μg kg -1 detected by the GC and HPLC method, respectively. The concentrations determined with the two different quantitative methods corresponded well with each other. A convenient and fast pretreatment procedure will be optimized in order to satisfy further investigation of hundreds of samples

  9. A comprehensive procedure based on gas chromatography–isotope ratio mass spectrometry following high performance liquid chromatography purification for the analysis of underivatized testosterone and its analogues in human urine

    International Nuclear Information System (INIS)

    Torre, Xavier de la; Colamonici, Cristiana; Curcio, Davide; Molaioni, Francesco; Botrè, Francesco

    2012-01-01

    Highlights: ► Overall approach for urine samples purification by HPLC for subsequent GC/C/IRMS analysis in doping control. ► Detection of pseudo-endogenous androgenic steroids (i.e. testosterone, androstenedione) misuse in sports. ► Routine analysis of steroids by GC/C/IRMS in sports drug testing. - Abstract: The confirmation by GC/C/IRMS of the exogenous origin of pseudo-endogenous steroids from human urine samples requires extracts of adequate purity. A strategy based on HPLC sample purification prior to the GC/C/IRMS analysis of human urinary endogenous androgens (i.e. testosterone, androsterone and/or androstenediols), is presented. A method without any additional derivatization step is proposed, allowing to simplify the urine pretreatment procedure, leading to extracts free of interferences permitting precise and accurate IRMS analysis, without the need of correcting the measured delta values for the contribution of the derivatizing agent. The HPLC extracts were adequately combined to both reduce the number of GC/C/IRMS runs and to have appropriate endogenous reference compounds (ERC; i.e. pregnanediol, 11-keto-etiocholanolone) on each GC–IRMS run. The purity of the extracts was assessed by their parallel analysis by gas chromatography coupled to mass spectrometry, with GC conditions identical to those of the GC/C/IRMS assay. The method has been validated according to ISO17025 requirements (within assay precision below 0.3 ‰ 13 C delta units and between assay precision below 0.6 ‰ 13 C delta units for most of the compounds investigated) fulfilling the World Anti-Doping Agency requirements.

  10. Minimizing technical variation during sample preparation prior to label-free quantitative mass spectrometry.

    Science.gov (United States)

    Scheerlinck, E; Dhaenens, M; Van Soom, A; Peelman, L; De Sutter, P; Van Steendam, K; Deforce, D

    2015-12-01

    Sample preparation is the crucial starting point to obtain high-quality mass spectrometry data and can be divided into two main steps in a bottom-up proteomics approach: cell/tissue lysis with or without detergents and a(n) (in-solution) digest comprising denaturation, reduction, alkylation, and digesting of the proteins. Here, some important considerations, among others, are that the reagents used for sample preparation can inhibit the digestion enzyme (e.g., 0.1% sodium dodecyl sulfate [SDS] and 0.5 M guanidine HCl), give rise to ion suppression (e.g., polyethylene glycol [PEG]), be incompatible with liquid chromatography-tandem mass spectrometry (LC-MS/MS) (e.g., SDS), and can induce additional modifications (e.g., urea). Taken together, all of these irreproducible effects are gradually becoming a problem when label-free quantitation of the samples is envisioned such as during the increasingly popular high-definition mass spectrometry (HDMS(E)) and sequential window acquisition of all theoretical fragment ion spectra (SWATH) data-independent acquisition strategies. Here, we describe the detailed validation of a reproducible method with sufficient protein yield for sample preparation without any known LC-MS/MS interfering substances by using 1% sodium deoxycholate (SDC) during both cell lysis and in-solution digest. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  11. Carboxylic acid functional group analysis using constant neutral loss scanning-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dron, Julien [Laboratoire de Chimie et Environnement, Marseille Universites (case 29), 3 place Victor Hugo, 13331 Marseille Cedex 3 (France)], E-mail: julien.dron@up.univ-mrs.fr; Eyglunent, Gregory; Temime-Roussel, Brice; Marchand, Nicolas; Wortham, Henri [Laboratoire de Chimie et Environnement, Marseille Universites (case 29), 3 place Victor Hugo, 13331 Marseille Cedex 3 (France)

    2007-12-12

    The present study describes the development of a new analytical technique for the functional group determination of the carboxylic moiety using atmospheric pressure chemical ionization-mass spectrometry (APCI-MS/MS) operated in the constant neutral loss scanning (CNLS) mode. Carboxylic groups were first derivatized into their corresponding methyl esters by reacting with BF{sub 3}/methanol mix and the reaction mixture was then directly injected into the APCI chamber. The loss of methanol (m/z = 32 amu) resulting from the fragmentation of the protonated methyl esters was then monitored. Applying this method together with a statistical approach to reference mixtures containing 31 different carboxylic acids at randomly calculated concentrations demonstrated its suitability for quantitative functional group measurements with relative standard deviations below 15% and a detection limit of 0.005 mmol L{sup -1}. Its applicability to environmental matrices was also shown through the determination of carboxylic acid concentrations inside atmospheric aerosol samples. To the best of our knowledge, it is the first time that the tandem mass spectrometry was successfully applied to functional group analysis, offering great perspectives in the characterization of complex mixtures which are prevailing in the field of environmental analysis as well as in the understanding of the chemical processes occurring in these matrices.

  12. Carboxylic acid functional group analysis using constant neutral loss scanning-mass spectrometry

    International Nuclear Information System (INIS)

    Dron, Julien; Eyglunent, Gregory; Temime-Roussel, Brice; Marchand, Nicolas; Wortham, Henri

    2007-01-01

    The present study describes the development of a new analytical technique for the functional group determination of the carboxylic moiety using atmospheric pressure chemical ionization-mass spectrometry (APCI-MS/MS) operated in the constant neutral loss scanning (CNLS) mode. Carboxylic groups were first derivatized into their corresponding methyl esters by reacting with BF 3 /methanol mix and the reaction mixture was then directly injected into the APCI chamber. The loss of methanol (m/z = 32 amu) resulting from the fragmentation of the protonated methyl esters was then monitored. Applying this method together with a statistical approach to reference mixtures containing 31 different carboxylic acids at randomly calculated concentrations demonstrated its suitability for quantitative functional group measurements with relative standard deviations below 15% and a detection limit of 0.005 mmol L -1 . Its applicability to environmental matrices was also shown through the determination of carboxylic acid concentrations inside atmospheric aerosol samples. To the best of our knowledge, it is the first time that the tandem mass spectrometry was successfully applied to functional group analysis, offering great perspectives in the characterization of complex mixtures which are prevailing in the field of environmental analysis as well as in the understanding of the chemical processes occurring in these matrices

  13. Spectrophotometric determination of phenylpropanolamine in dosage forms using dimethylaminobenzaldehyde as a derivatizing reagent

    International Nuclear Information System (INIS)

    Rind, F.M.A.; Khushawar, M.Y.

    2000-01-01

    Phenylpropanolamine (PPA) was extracted from slightly alkaline medium in chloroform, derivatized with dimethylaminobenzaldehyde (DAB) and determined by spectrophotometry at 377 nm. Beer's law was obeyed for 4.5-13.5 mu g. After the extraction of PPA in organic phase, paracetamole remaining in the aqueous phase could also be determined by spectrophotometry at 291 nm. The method was applied for the determination of PPA and paracetamole in the pharmaceutical preparations. Tavagyl-D, sinulab and Panadol labels with RSD within 0.4-0.8%. (author)

  14. Investigation of pH response and photo-control of wettability on spiropyran-derivatized surfaces

    Science.gov (United States)

    Park, Choong-Do

    2009-12-01

    One promising method to control a liquid drop on a surface for microfluidic devices is to use the surface tension gradient on a photo-responsive surface by light irradiation. A photo-switchable spiropyran monolayer was prepared on smooth glass or silicon wafers via 3-aminopropylmethyldiethoxysilane linkages. The pH response of the surface-bound spiropyran was investigated by measuring contact angle as a function of pH, since the pH value of the liquids applied to a microfluidic system can vary widely. Based on the contact angle titration and UV-Vis spectroscopic data, a protonation and deprotonation mechanism of the surface-bound spiropyran was proposed. The advancing contact angles under UV and under visible light irradiation at high pH values were about 100 smaller than those at low pH values. The decrease in contact angle under UV light with decreasing pH value was assigned to the protonation of open merocyanine (MC) to MC-OH+. Meanwhile, the decrease in contact angle under visible light was attributed to the protonation of the closed spiropryan (SP), generating a mixed state of MC-OH+ in equilibrium with N-protonated SP-NH+. In order to examine the possibility of light-induced liquid drop motion on the spiropyran-derivatized smooth surfaces, the light-induced surface tension change between SP and MC was estimated using the contact angle hysteresis (CAH) and the Lifshitz---van der Waals/Acid-Base (LWAB) approaches based on the contact angle data. The average light-induced surface energy change between the two isomers under UV and visible light exposure was 1.4 mJ/m 2, implying that the small change in surface tension is not sufficient to move a liquid droplet on the surface. Liquid drop motion requires that the light-induced switching angle be greater than the contact angle hysteresis. However, the light-induced switching angle of the spiropyran-derivatized surface was significantly smaller than the hysteresis. Thus, in order to achieve liquid drop motion on the

  15. 丹磺酰氯对异丙酚荧光衍生化的工艺研究%Study on preparation process of propofol fluorescence derivatization by dansyl chloride

    Institute of Scientific and Technical Information of China (English)

    李莹; 李莉

    2016-01-01

    目的:以丹磺酰氯(DNS-Cl)作为荧光衍生化试剂对异丙酚进行荧光衍生化方法的研究与探讨。方法 DNS-Cl 对异丙酚荧光衍生化后,衍生产物用荧光分光光度法检测,通过单因素变量法考察衍生化条件。结果当 DNS-Cl 与异丙酚的摩尔比为8∶1,在浓度为0.1 mol/L 氢氧化钠碱性条件下60℃水浴避光反应5 min后,衍生产物用环己烷萃取1 min 效果最佳。结论该荧光衍生化条件温和、反应速度快,DNS-Cl 可以应用于异丙酚的衍生化。%Objiective To explore preparation process of fluorescence derivatization for propofol by using dansyl chloride as derivatization reagent.Methods Utilize the reaction of propofol and the DNS-Cl to ob-tain a fluorescent derivative product which was detected by fluorospectrophotometry.And investigate deri-vatization conditions by single-factor variable method.Results The results of derivatization indicated that the derivatives could be obtained by the labeling reaction of DNS-Cl with propofol (DNS-Cl:propofol=8:1 in mole ratio)in the presence of sodium hydroxide (0.1 mol/L)at 60℃ for 5 min in the dark,then using cyclohexane to extract for 1 min.Conclusion DNS-Cl could be applied to derivatize for propofol,the reac-tion condition was mild and the reaction velosity is fast in the fluorescence derivatization.

  16. Alkylation or Silylation for Analysis of Amino and Non-Amino Organic Acids by GC-MS?

    Directory of Open Access Journals (Sweden)

    Silas G. Villas-Bôas

    2011-01-01

    Full Text Available Gas chromatography–mass spectrometry (GC-MS is a widely used analytical technique in metabolomics. GC provides the highest resolution of any standard chromatographic separation method, and with modern instrumentation, retention times are very consistent between analyses. Electron impact ionization and fragmentation is generally reproducible between instruments and extensive libraries of spectra are available that enhance the identification of analytes. The major limitation is the restriction to volatile analytes, and hence the requirement to convert many metabolites to volatile derivatives through chemical derivatization. Here we compared the analytical performance of two derivatization techniques, silylation (TMS and alkylation (MCF, used for the analysis of amino and non-amino organic acids as well as nucleotides in microbial-derived samples. The widely used TMS derivatization method showed poorer reproducibility and instability during chromatographic runs while the MCF derivatives presented better analytical performance. Therefore, alkylation (MCF derivatization seems to be preferable for the analysis of polyfunctional amines, nucleotides and organic acids in microbial metabolomics studies.

  17. Quantification of isocyanates and amines in polyurethane foams and coated products by liquid chromatography–tandem mass spectrometry

    Science.gov (United States)

    Mutsuga, Motoh; Yamaguchi, Miku; Kawamura, Yoko

    2014-01-01

    An analytical method for the identification and quantification of 10 different isocyanates and 11 different amines in polyurethane (PUR) foam and PUR-coated products was developed and optimized. Isocyanates were extracted and derivatized with di-n-butylamine, while amines were extracted with methanol. Quantification was subsequently performed by liquid chromatography–tandem mass spectrometry. Using this methodology, residual levels of isocyanates and amines in commercial PUR products were quantified. Although the recoveries of certain isocyanates and amines were low, the main compounds used as monomers in the production of PUR products, and their decomposition species, were clearly identified at quantifiable levels. 2,4-and 2,6-toluenediisocyanate were detected in most PUR foam samples and a pastry bag in the range of 0.02–0.92 mg/kg, with their decomposition compounds, 2,4-and 2,6-toluenediamine, detected in all PUR foam samples in the range of 9.5–59 mg/kg. PUR-coated gloves are manufactured using 4,4′-methylenebisphenyl diisocyanate as the main raw material, and a large amount of this compound, in addition to 4,4′-methylenedianiline and dicyclohexylmethane-4,4′-diamine were found in these samples. PMID:24804074

  18. Simultaneous determination of dihydrotestosterone and its metabolites in mouse sera by LC-MS/MS with chemical derivatization.

    Science.gov (United States)

    Gorityala, Shashank; Yang, Shuming; Montano, Monica M; Xu, Yan

    2018-07-15

    Androgens play a vital role in prostate cancer development, and their elimination and blockade are essential in the disease management. DHT is the key ligand for androgen receptor (AR) in the prostate. It is locally synthesized from testosterone. In the prostate, DHT is predominantly metabolized to α-diol and β-diol. Recent studies indicate that impaired DHT catabolism is associated with prostate cancer, signifying the necessity of a sensitive quantitative method for the determination of DHT and its metabolites. In this work, an LC-MS/MS method for the simultaneous quantification of DHT and its metabolites was developed and validated. Steroid-free sera were prepared and used for the preparation of sera calibrators and quality controls (QCs). DHT and its metabolites along with their respective stable heavy isotope labeled analytes representing internal standards were first extracted with methyl tertiary-butyl ether (MTBE) and derivatized with picolinic acid (PA). The derivatized analytes were then extracted again with MTBE, dried under nitrogen and reconstituted in the mobile phase (80% methanol and 0.2% formic acid in water). Baseline chromatographic separation of the derivatized analytes was achieved isocratically on XTerra C18 column (2.1 × 100 mm) using the mobile phase at a flow rate of 0.25 mL/min. Quantitation was performed using multiple-reaction-monitoring mode with positive electrospray ionization. The method has calibration ranges from 0.0500 ng/mL to 50.0 ng/mL for DHT and its two metabolites with acceptable assay precision, accuracy, recovery, and matrix factor. It was applied to the determination of DHT and its metabolites in an animal study. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Gas chromatographic/mass spectrometric characterization of dromostanolone metabolites in human urine

    International Nuclear Information System (INIS)

    Kim, Tae Wook; Choi, Man Ho; Jung, Byung Hwa; Chung, Bong Chul

    1998-01-01

    The metabolism of dromostanolone (2α-methyl-5α-androstan-17β-ol-3-one) was studied in three adult volunteers after oral dose of 20 mg. Solvent extracts of urine obtained after enzyme hydrolysis were derivatized with MSTFA/TMCS and MSTFA/TMIS. The structures of intact drug and its metabolites were determined by gas chromatography/mass spectrometry (GC/MS) in electron impact (EI) mode. The major metabolite (2α-methyl-5α-androstan-3α-ol-17-one), its 3β-epimer, parent compound, and several hydroxylated metabolites including intact drug were detected by comparing total ion chromatograms of control urine with that of the administered sample. Two epimers of 2α-methyl-5α-androstan-3, 17β-diol were detected using selected ion monitoring. The maximum excretion of dromostanolone and 2α-methyl-5α-androstan-3α-ol-17-one was reached in 6.2-15 hr. The half-life of intact dromostanolone was 5.3 hr. About 3.0% of the administered amount was found to be excreted within 95 hr as unchanged form

  20. New method for determination of epichlorohydrin in epoxy-coated cans by oxolane derivatization and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Sung, Jun Hyun; Lee, Young Ja; Park, Hyun Jin

    2008-08-01

    A new method was developed for the determination of epichlorohydrin (ECH) in food contact surface of epoxy-coated cans. The oxolane derivative, which produced by reaction of epoxy moiety in ECH with cyclopentanone in the presence of borontrifluoride-diethyletherate, was analyzed by gas chromatography (GC)/mass spectrometry (MS). 1,2-Epoxyhexane was used as internal standard (IS), which produced an oxolane derivative under the same reaction mechanism as ECH. The developed method was validated with 1 ng ml(-1) of limit of detection (LOD, surface area related 20 ng dm(-2)), >0.999 of linearity. Good precision, which was tested both in terms of intra-day repeatability and inter-day reproducibility, and 97.3-102.7% of good recoveries were obtained on three spiked levels of 5.2, 40.3 and 149.1 ng ml(-1). The excellent validation data suggests that this method is more simple, quick and effective than the official method in European Committee for Standardization (CEN) to determine the residual amount of ECH in food contact materials for food law compliance test. The residual amount of ECH for 13 epoxy-coated can samples was analyzed, and none of the samples was found to be detectable levels of ECH in epoxy-coated cans.

  1. Computer automated mass spectrometer for isotope analysis on gas samples

    International Nuclear Information System (INIS)

    Pamula, A.; Kaucsar, M.; Fatu, C.; Ursu, D.; Vonica, D.; Bendea, D.; Muntean, F.

    1998-01-01

    A low resolution, high precision instrument was designed and realized in the mass spectrometry laboratory of the Institute of Isotopic and Molecular Technology, Cluj-Napoca. The paper presents the vacuum system, the sample inlet system, the ion source, the magnetic analyzer and the ion collector. The instrument is almost completely automated. There are described the analog-to-digital conversion circuits, the local control microcomputer, the automation systems and the performance checking. (authors)

  2. Systematic Comparison of Reverse Phase and Hydrophilic Interaction Liquid Chromatography Platforms for the Analysis of N-linked Glycans

    Science.gov (United States)

    Walker, S. Hunter; Carlisle, Brandon C.; Muddiman, David C.

    2013-01-01

    Due to the hydrophilic nature of glycans, reverse phase chromatography has not been widely used as a glycomic separation technique coupled to mass spectrometry. Other approaches such as hydrophilic interaction chromatography and porous graphitized carbon chromatography are often employed, though these strategies frequently suffer from decreased chromatographic resolution, long equilibration times, indefinite retention, and column bleed. Herein, it is shown that through an efficient hydrazone formation derivatization of N-linked glycans (∼4 hr of additional sample preparation time which is carried out in parallel), numerous experimental and practical advantages are gained when analyzing the glycans by online reverse phase chromatography. These benefits include an increased number of glycans detected, increased peak capacity of the separation, and the ability to analyze glycans on the identical liquid chromatography-mass spectrometry platform commonly used for proteomic analyses. The data presented show that separation of derivatized N-linked glycans by reverse phase chromatography significantly out-performs traditional separation of native or derivatized glycans by hydrophilic interaction chromatography. Furthermore, the movement to a more ubiquitous separation technique will afford numerous research groups the opportunity to analyze both proteomic and glycomic samples on the same platform with minimal time and physical change between experiments, increasing the efficiency of ‘multi-omic’ biological approaches. PMID:22954204

  3. Determination of steroids, caffeine and methylparaben in water using solid phase microextraction-comprehensive two dimensional gas chromatography-time of flight mass spectrometry.

    Science.gov (United States)

    Lima Gomes, Paulo C F; Barnes, Brian B; Santos-Neto, Álvaro J; Lancas, Fernando M; Snow, Nicholas H

    2013-07-19

    Analysis of several emerging contaminants (steroids, caffeine and methylparaben) in water using automated solid-phase microextraction with comprehensive two dimensional gas chromatography coupled to time of flight mass spectrometry (SPME-GCxGC-ToF/MS) is presented. Experimental design was used to determine the best SPME extraction conditions and the steroids were not derivatized prior to injection. SPME-GCxGC-ToF/MS provided linear ranges from 0.6 to 1200μgL(-1) and limits of detection and quantitation from 0.02 to 100μgL(-1). A series of river water samples obtained locally were subjected to analysis. SPME-GCxGC-ToF/MS is readily automated, straightforward and competitive with other methods for low level analysis of emerging contaminants. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Negative chemical ionization GC/MS determination of nitrite and nitrate in seawater using exact matching double spike isotope dilution and derivatization with triethyloxonium tetrafluoroborate.

    Science.gov (United States)

    Pagliano, Enea; Meija, Juris; Sturgeon, Ralph E; Mester, Zoltan; D'Ulivo, Alessandro

    2012-03-06

    The alkylation of nitrite and nitrate by triethyloxonium tetrafluoroborate allows determination of their ethyl esters by headspace gas chromatography/mass spectrometry (GC/MS). In the present study, significant improvement in analytical performance is achieved using negative chemical ionization providing detection limits of 150 ng/L for NO(2)(-) and 600 ng/L for NO(3)(-), an order of magnitude better than those achieved using electron impact ionization. The derivatization procedure was optimized and alkaline conditions adopted to minimize conversion of nitrite to nitrate (determined to be 0.07% at 100 mg/L NO(2)(-)) and to avoid the exchange of oxygen between the analytes and the solvent (water). Quantitation entails use of isotopically enriched standards (N(18)O(2)(-) and (15)NO(3)(-)), which also permits monitoring of potential conversion from nitrite to nitrate during the analysis (double spike isotope dilution).

  5. Improved Gas Chromatographic Determination of Guanidino Compounds Using Isovaleroylacetone and Ethyl Chloroformate as Derivatizing Reagents.

    Science.gov (United States)

    Zounr, Rizwan Ali; Khuhawar, Mumammad Yar; Jahangir, Taj Muhammad; Alamgir, Malik

    2016-01-01

    An improved GC method in terms of sensitivity and decrease in the analysis time has been developed for the analysis of eight guanidino compounds: guanidine (G), methylguanidine (MG), creatinine (CTN), guanidinoacetic acid (GAA), guanidinobutyric acid (GBA), guanidinopropionic acid (GPA), argenine (Arg), and guanidinosuccinic acid (GSA), using isovaleroylacetone (IVA) and ethyl chloroformate (ECF) as derivatizing reagents. The separation was obtained from column HP-5 (30 m × 0.32 mm i.d.) with film thickness of 0.25 μm within 11 min. The linear calibrations were obtained with 0.5 to 50 μg/mL with coefficient of determination (R(2)) within 0.9969 - 0.9998. Limits of detections (LODs) were within 5 - 140 ng/mL. The derivatization, separation and determination was repeatable (n = 6) with relative standard deviation (RSD) within 1.2 - 3.1%. The guanidino compounds were determined in deproteinized serum of healthy volunteers and uremic patients within below LOD to 8.8 μg/mL and below LOD to 43.99 μg/mL with RSD within 1.4 - 3.6%. The recovery of guanidino compounds calculated by standard addition from serum was within 96.1 - 98.9%, with RSD 1.4 - 3.6%.

  6. Trace analysis of plutonium in environmental samples by resonance ionization mass spectroscopy (RIMS)

    International Nuclear Information System (INIS)

    Erdmann, N.; Herrmann, G.; Huber, G.; Koehler, S.; Kratz, J.V.; Mansel, A.; Nunnemann, M.; Passler, G.; Trautmann, N.; Waldek, A.

    1997-01-01

    Trace amounts of plutonium in the environment can be detected by resonance ionization mass spectroscopy (RIMS). An atomic beam of plutonium is produced after its chemical separation and deposition on a filament. The atoms are ionized by a three-step excitation using pulsed dye-lasers. The ions are mass-selectively detected in a time-of-flight (TOF) mass spectrometer. With this setup a detection limit of 1·10 6 atoms of plutonium has been achieved. Furthermore, the isotopic composition can be determined. Different samples, including soil from the Chernobyl area, IAEA-certified sediments from the Mururoa Atoll and urine, have been investigated. copyright 1997 American Institute of Physics

  7. Direct Analysis of Samples of Various Origin and Composition Using Specific Types of Mass Spectrometry.

    Science.gov (United States)

    Byliński, Hubert; Gębicki, Jacek; Dymerski, Tomasz; Namieśnik, Jacek

    2017-07-04

    One of the major sources of error that occur during chemical analysis utilizing the more conventional and established analytical techniques is the possibility of losing part of the analytes during the sample preparation stage. Unfortunately, this sample preparation stage is required to improve analytical sensitivity and precision. Direct techniques have helped to shorten or even bypass the sample preparation stage; and in this review, we comment of some of the new direct techniques that are mass-spectrometry based. The study presents information about the measurement techniques using mass spectrometry, which allow direct sample analysis, without sample preparation or limiting some pre-concentration steps. MALDI - MS, PTR - MS, SIFT - MS, DESI - MS techniques are discussed. These solutions have numerous applications in different fields of human activity due to their interesting properties. The advantages and disadvantages of these techniques are presented. The trends in development of direct analysis using the aforementioned techniques are also presented.

  8. Application of secondary ion mass spectrometry (SIMS) to biological sample analysis

    International Nuclear Information System (INIS)

    Tamura, Hifumi

    1990-01-01

    Some major issues and problems related with the analysis of biological samples are discussed, focusing on demonstrated and possible solutions and the application of secondary ion mass spectrometry (SIMS) to investigation of the composition of biological samples. The effective use of secondary electrons in combination with negative ions is most practical for the analysis of biological samples. Regardless of whether positive or negative ions are used, the electric potential at the surface of a sample stays around a constant value because of the absense of the accumulation of electric charges at the surface, leading to almost complete avoidance of the charging of the biological sample. A soft tissue sample can suffer damage to the tissue or migration of atoms in removing water from the sample. Some processes including fixation and freeze drying are available to prevent this. The application of SIMS to biological analysis is still in the basic research stage and further studies will be required to develop practical methods. Possible areas of its application include medicine, pathology, toxicology, pharmacology, plant physiology and other areas related with marine life and marine contamination. (N.K.)

  9. Highly Reproducible Automated Proteomics Sample Preparation Workflow for Quantitative Mass Spectrometry.

    Science.gov (United States)

    Fu, Qin; Kowalski, Michael P; Mastali, Mitra; Parker, Sarah J; Sobhani, Kimia; van den Broek, Irene; Hunter, Christie L; Van Eyk, Jennifer E

    2018-01-05

    Sample preparation for protein quantification by mass spectrometry requires multiple processing steps including denaturation, reduction, alkylation, protease digestion, and peptide cleanup. Scaling these procedures for the analysis of numerous complex biological samples can be tedious and time-consuming, as there are many liquid transfer steps and timed reactions where technical variations can be introduced and propagated. We established an automated sample preparation workflow with a total processing time for 96 samples of 5 h, including a 2 h incubation with trypsin. Peptide cleanup is accomplished by online diversion during the LC/MS/MS analysis. In a selected reaction monitoring (SRM) assay targeting 6 plasma biomarkers and spiked β-galactosidase, mean intraday and interday cyclic voltammograms (CVs) for 5 serum and 5 plasma samples over 5 days were samples repeated on 3 separate days had total CVs below 20%. Similar results were obtained when the workflow was transferred to a second site: 93% of peptides had CVs below 20%. An automated trypsin digestion workflow yields uniformly processed samples in less than 5 h. Reproducible quantification of peptides was observed across replicates, days, instruments, and laboratory sites, demonstrating the broad applicability of this approach.

  10. Direct determination of trace rare earth elements in ancient porcelain samples with slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Xiang Guoqiang; Jiang Zucheng; He Man; Hu Bin

    2005-01-01

    A method for the direct determination of trace rare earth elements in ancient porcelain samples by slurry sampling fluorinating electrothermal vaporization inductively coupled plasma mass spectrometry was developed with the use of polytetrafluoroethylene as fluorinating reagent. It was found that Si, as a main matrix element in ancient porcelain sample, could be mostly removed at the ashing temperature of 1200 deg. C without considerable losses of the analytes. However, the chemical composition of ancient porcelain sample is very complicated, which makes the influences resulting from other matrix elements not be ignored. Therefore, the matrix effect of ancient porcelain sample was also investigated, and it was found that the matrix effect is obvious when the matrix concentration was larger than 0.8 g l -1 . The study results of particle size effect indicated that when the sample particle size was less than 0.057 mm, the particle size effect is negligible. Under the optimized operation conditions, the detection limits for rare earth elements by fluorinating electrothermal vaporization inductively coupled plasma mass spectrometry were 0.7 ng g -1 (Eu)-33.3 ng g -1 (Nd) with the precisions of 4.1% (Yb)-10% (La) (c = 1 μg l -1 , n = 9). The proposed method was used to directly determine the trace rare earth elements in ancient porcelain samples produced in different dynasty (Sui, Ming and Qing), and the analytical results are satisfactory

  11. On Selective Derivatization of meso-Tetraarylporphyrins (A Microreview)

    International Nuclear Information System (INIS)

    Ostrowski, S.

    2003-01-01

    The studies on selective derivatization in one or two aromatic rings of meso-tetraarylporphyrin systems (and their zinc and copper complexes) using (a) selective nitration, (b) Vicarious Nucleophilic Substitution of Hydrogen(VNS), and (c) alkylation of the above intermediates with alkyl halides, are reported. The stepwise selective nitration of meso-aryl substituted porphyrins with fuming yellow nitric acid (d= 1.53) at the tempreture 0 deg to 20 deg results in the formation of 5-(4-nitroaryl)- 10, 15, 20-triarylporphyrins, 5,10-bis(4-nitroaryl)-15,20-diarylporphrins or trinitro- and tetranitro-derivatives, respectively, in good or reasonable yield. The above intermediates, after simple transformation to their copper or zinc complexes react with carbanions bearing leaving groups at the carbanionic center, according to VNS scheme. This reaction can be also realized at low temperature (-30 deg- 40 deg) without complexation of the parent nitroporphyrins. Alkylation of the products obtained with alkyl halides or alkyl halides bearing multiple bonds in the carbon chain led to useful compounds for further functionalization . (Author) 53 refs., 7sches., 4 figs

  12. Tuneable surface enhanced Raman spectroscopy hyphenated to chemically derivatized thin-layer chromatography plates for screening histamine in fish.

    Science.gov (United States)

    Xie, Zhengjun; Wang, Yang; Chen, Yisheng; Xu, Xueming; Jin, Zhengyu; Ding, Yunlian; Yang, Na; Wu, Fengfeng

    2017-09-01

    Reliable screening of histamine in fish was of urgent importance for food safety. This work presented a highly selective surface enhanced Raman spectroscopy (SERS) method mediated by thin-layer chromatography (TLC), which was tailored for identification and quantitation of histamine. Following separation and derivatization with fluram, plates were assayed with SERS, jointly using silver nanoparticle and NaCl. The latter dramatically suppressed the masking effect caused by excessive fluram throughout the plate, thus offering clear baseline and intensive Raman fingerprints specific to the analyte. Under optimized conditions, the usability of this method was validated by identifying the structural fingerprints of both targeted and unknown compounds in fish samples. Meanwhile, the quantitative results of this method agreed with those by an HPLC method officially suggested by EU for histamine determination. Showing remarkable cost-efficiency and user-friendliness, this facile TLC-SERS method was indeed screening-oriented and may be more attractive to controlling laboratories of limited resource. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. A microanalytical method for ammonium and short-chain primary aliphatic amines using precolumn derivatization and capillary liquid chromatography.

    Science.gov (United States)

    Moliner-Martínez, Y; Herráez-Hernández, R; Campíns-Falcó, P

    2007-09-14

    A new microscale method is presented for the determination of ammonium and primary short-chain aliphatic amines (methylamine, ethylamine, propylamine, n-butylamine and n-pentylamine) in water. The assay uses precolumn derivatization with the reagent o-phthaldialdehyde (OPA) in combination with the thiol N-acetyl-L-cysteine (NAC), and capillary liquid chromatography with UV detection at 330 nm. The described method is very simple and rapid as no preconcentration of the analytes is necessary, and the volume of sample required is only 0.1 mL. Under the proposed conditions good linearity has been obtained up to a concentration of the analytes of 10.0 mgL(-1), the limits of detection being of 8-50 microgL(-1). No matrix effect was found, and recoveries between 97 and 110% were obtained. The precision of the method was good, and the achieved variation coefficients were below 12%. The reliability of the proposed approach has been tested by analyzing a microsample of fogwater collected from leaf surfaces.

  14. Analysis of arsenic and calcium in soil samples by laser ablation mass spectrometry

    International Nuclear Information System (INIS)

    Beccaglia, Ana M.; Rinaldi, Carlos A.; Ferrero, Juan C.

    2006-01-01

    We present an analytical procedure based on laser ablation mass spectrometry (LAMS) in order to detect and quantify arsenic and calcium in soil samples and we analyze the diverse factors that influence the precision of LAMS, such as laser fluence and matrix effect. The results indicate that a Zn matrix is a good choice for the analysis of those metals in soil samples. This work also provides a method for the direct determination of As in soil samples whose concentrations are lower than 100 ppm with a 70 ppm minimum detection limits (MDL)

  15. Burn-up determination of irradiated thoria samples by isotope dilution-thermal ionisation mass spectrometry

    International Nuclear Information System (INIS)

    Aggarwal, S.K.; Jaison, P.G.; Telmore, V.M.; Shah, R.V.; Sant, V.L.; Sasibhushan, K.; Parab, A.R.; Alamelu, D.

    2010-03-01

    Burn-up was determined experimentally using thermal ionization mass spectrometry for two samples from ThO 2 bundles irradiated in KAPS-2. This involved quantitative dissolution of the irradiated fuel samples followed by separation and determination of Th, U and a stable fission product burn-up monitor in the dissolved fuel solution. Stable fission product 148 Nd was used as a burn-up monitor for determining the number of fissions. Isotope Dilution-Thermal Ionisation Mass Spectrometry (ID-TIMS) using natural U, 229 Th and enriched 142 Nd as spikes was employed for the determination of U, Th and Nd, respectively. Atom % fission values of 1.25 ± 0.03 were obtained for both the samples. 232 U content in 233 U determined by alpha spectrometry was about 500 ppm and this was higher by a factor of 5 compared to the theoretically predicted value by ORIGEN-2 code. (author)

  16. Automated extraction of lysergic acid diethylamide (LSD) and N-demethyl-LSD from blood, serum, plasma, and urine samples using the Zymark RapidTrace with LC/MS/MS confirmation.

    Science.gov (United States)

    de Kanel, J; Vickery, W E; Waldner, B; Monahan, R M; Diamond, F X

    1998-05-01

    A forensic procedure for the quantitative confirmation of lysergic acid diethylamide (LSD) and the qualitative confirmation of its metabolite, N-demethyl-LSD, in blood, serum, plasma, and urine samples is presented. The Zymark RapidTrace was used to perform fully automated solid-phase extractions of all specimen types. After extract evaporation, confirmations were performed using liquid chromatography (LC) followed by positive electrospray ionization (ESI+) mass spectrometry/mass spectrometry (MS/MS) without derivatization. Quantitation of LSD was accomplished using LSD-d3 as an internal standard. The limit of quantitation (LOQ) for LSD was 0.05 ng/mL. The limit of detection (LOD) for both LSD and N-demethyl-LSD was 0.025 ng/mL. The recovery of LSD was greater than 95% at levels of 0.1 ng/mL and 2.0 ng/mL. For LSD at 1.0 ng/mL, the within-run and between-run (different day) relative standard deviation (RSD) was 2.2% and 4.4%, respectively.

  17. Simultaneous quantification of twenty Amadori products in soy sauce using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Katayama, Hiroshi; Tatemichi, Yuki; Nakajima, Ayako

    2017-08-01

    A liquid chromatography-tandem mass spectrometry method using a pentafluorophenylpropyl-bonded silica column was developed to simultaneously quantify twenty Amadori products (APs), including N-(1-Deoxy-d-fructosyl-1-yl)-l-isoleucine (Fru-Ile) and N-(1-Deoxy-d-fructosyl-1-yl)-l-leucine (Fru-Leu), in soy sauce, without the need for an ion-pairing reagent or sample derivatization. The method was applied to six types of soy sauce, to determine the total AP levels and the levels of individual APs. The level of total APs widely varied between the eight samples, from 358mg/L to 24347mg/L. The concentrations of N-ε-(1-deoxy-d-fructosyl-1-yl)-l-lysine (Fru-Lys) and N-(1-deoxy-d-fructosyl-1-yl)-l-pyroglutamic acid (Fru-pGlu) were the highest among the APs and the level of Fru-pGlu was similar to that of Fru-Lys. Furthermore, fermentation periods of up to six months greatly influenced AP levels in soy sauce but the levels remained constant thereafter. Thermal treatment of soy sauce had little effect on AP levels. Copyright © 2017. Published by Elsevier Ltd.

  18. Gas chromatographic/mass spectrometric determination of carbon isotope composition in unpurified samples: methamphetamine example.

    Science.gov (United States)

    Low, I A; Liu, R H; Legendre, M G; Piotrowski, E G; Furner, R L

    1986-10-01

    A gas chromatograph/quadrupole mass spectrometer system, operated in electron impact/selected ion monitoring mode, is used to determine the intensity ratio of the m/z 59 and the m/z 58 ions of the [C3H8N]+ fragment derived from methamphetamine samples synthesized with varying amounts of 13C-labeled methylamine. Crude products are introduced into the gas chromatograph without prior cleanup. The ratios measured were in excellent agreement with those calculated. A change in 0.25% use of 13C-methylamine is sufficient for product differentiation. The feasibility of using isotope labeling and subsequent mass spectrometric isotope ratio measurement as the basis of a compound tracing mechanism is discussed. Specifically, if methamphetamine samples manufactured from legal sources are asked to incorporate distinct 13C compositions, their sources can be traced when samples are diverted into illegal channels. Samples derived from illicit preparations can also be traced if the manufacturers of a precursor (methylamine in this case) incorporate distinct 13C compositions in their products.

  19. Preparative purification of a high-mannose type N-glycan from soy bean agglutinin by hydrazinolysis and tyrosinamide derivatization.

    Science.gov (United States)

    Evers, D L; Hung, R L; Thomas, V H; Rice, K G

    1998-12-15

    The N-linked oligosaccharide from soy bean agglutinin (Man9) was isolated on a preparative scale following derivatization with Boc-tyrosine. The procedure utilized preparative hydrazinolysis to release the oligosaccharide and yielded multi-micromol quantities of Boc-tyrosine-Man9 which was characterized by 1H NMR and ES-MS. Copyright 1998 Academic Press.

  20. Influence of the derivatization procedure on the results of the gaschromatographic fatty acid analysis of human milk and infant formulae.

    Science.gov (United States)

    Kohn, G; van der Ploeg, P; Möbius, M; Sawatzki, G

    1996-09-01

    Many different analytical procedures for fatty acid analysis of infant formulae and human milk are described. The objective was to study possible pitfalls in the use of different acid-catalyzed procedures compared to a base-catalyzed procedure based on sodium-methoxide in methanol. The influence of the different methods on the relative fatty acid composition (wt% of total fatty acids) and the total fatty acid recovery rate (expressed as % of total lipids) was studied in two experimental LCP-containing formulae and a human milk sample. MeOH/HCl-procedures were found to result in an incomplete transesterification of triglycerides, if an additional nonpolar solvent like toluene or hexane is not added and a water-free preparation is not guaranteed. In infant formulae the low transesterification of triglycerides (up to only 37%) could result in an 100%-overestimation of the relative amount of LCP, if these fatty acids primarily derive from phospholipids. This is the case in infant formulae containing egg lipids as raw materials. In formula containing fish oils and in human milk the efficacy of esterification results in incorrect absolute amounts of fatty acids, but has no remarkable effect on the relative fatty acid distribution. This is due to the fact that in these samples LCP are primarily bound to triglycerides. Furthermore, in formulae based on butterfat the derivatization procedure should be designed in such a way that losses of short-chain fatty acids due to evaporation steps can be avoided. The procedure based on sodium methoxide was found to result in a satisfactory (about 90%) conversion of formula lipids and a reliable content of all individual fatty acids. Due to a possibly high amount of free fatty acids in human milk, which are not methylated by sodium-methoxide, caution is expressed about the use of this reagent for fatty acid analysis of mothers milk. It is concluded that accurate fatty acid analysis of infant formulae and human milk requires a careful

  1. Study of recovery and stability of derivatized gliphosate and AMPA in soil using national resins

    OpenAIRE

    Souza, Tomaz Alves de; Matta, Marcia Helena de Rizzo da; Montagner, Émerson; Abreu, Adley Bergson Gonçalves de

    2006-01-01

    In the present paper we studied the recoveries of glyphosate, N-(phosphonomethyl)glycine (GLY) and its major metabolite, (aminomethyl)phosphonic acid (AMPA) in soil using national (Brazilian) ion-exchange resins, derivatization by a mixture of trifluoroacetic anhydride and trifluoroethanol and analyses by GC-MS. The quantification limits were 12 ng.g-1 for both compounds and the methodology showed a range of recuperation from 85 to 94% with coefficients of variation (CV) ranging from 4.07 to ...

  2. A comprehensive procedure based on gas chromatography-isotope ratio mass spectrometry following high performance liquid chromatography purification for the analysis of underivatized testosterone and its analogues in human urine

    Energy Technology Data Exchange (ETDEWEB)

    Torre, Xavier de la, E-mail: xavier.delatorre@gmail.com [Laboratorio Antidoping, Federazione Medico Sportiva Italiana, Largo Giulio Onesti 1, 00197 Rome (Italy); Colamonici, Cristiana; Curcio, Davide; Molaioni, Francesco [Laboratorio Antidoping, Federazione Medico Sportiva Italiana, Largo Giulio Onesti 1, 00197 Rome (Italy); Botre, Francesco [Laboratorio Antidoping, Federazione Medico Sportiva Italiana, Largo Giulio Onesti 1, 00197 Rome (Italy); Dipartimento di Management, ' Sapienza' Universita di Roma, Via del Castro Laurenziano 9, 00161 Rome (Italy)

    2012-12-05

    Highlights: Black-Right-Pointing-Pointer Overall approach for urine samples purification by HPLC for subsequent GC/C/IRMS analysis in doping control. Black-Right-Pointing-Pointer Detection of pseudo-endogenous androgenic steroids (i.e. testosterone, androstenedione) misuse in sports. Black-Right-Pointing-Pointer Routine analysis of steroids by GC/C/IRMS in sports drug testing. - Abstract: The confirmation by GC/C/IRMS of the exogenous origin of pseudo-endogenous steroids from human urine samples requires extracts of adequate purity. A strategy based on HPLC sample purification prior to the GC/C/IRMS analysis of human urinary endogenous androgens (i.e. testosterone, androsterone and/or androstenediols), is presented. A method without any additional derivatization step is proposed, allowing to simplify the urine pretreatment procedure, leading to extracts free of interferences permitting precise and accurate IRMS analysis, without the need of correcting the measured delta values for the contribution of the derivatizing agent. The HPLC extracts were adequately combined to both reduce the number of GC/C/IRMS runs and to have appropriate endogenous reference compounds (ERC; i.e. pregnanediol, 11-keto-etiocholanolone) on each GC-IRMS run. The purity of the extracts was assessed by their parallel analysis by gas chromatography coupled to mass spectrometry, with GC conditions identical to those of the GC/C/IRMS assay. The method has been validated according to ISO17025 requirements (within assay precision below 0.3 Per-Mille-Sign {sup 13}C delta units and between assay precision below 0.6 Per-Mille-Sign {sup 13}C delta units for most of the compounds investigated) fulfilling the World Anti-Doping Agency requirements.

  3. Enantioselective micellar electrokinetic chromatography of dl-amino acids using (+)-1-(9-fluorenyl)-ethyl chloroformate derivatization and UV-induced fluorescence detection.

    Science.gov (United States)

    Prior, Amir; van de Nieuwenhuijzen, Erik; de Jong, Gerhardus J; Somsen, Govert W

    2018-05-22

    Chiral analysis of dl-amino acids was achieved by micellar electrokinetic chromatography coupled with UV-excited fluorescence detection. The fluorescent reagent (+)-1-(9-fluorenyl)ethyl chloroformate was employed as chiral amino acid derivatizing agent and sodium dodecyl sulfate served as pseudo-stationary phase for separating the formed amino acid diastereomers. Sensitive analysis of (+)-1-(9-fluorenyl)ethyl chloroformate-amino acids was achieved applying a xenon-mercury lamp for ultraviolet excitation, and a spectrograph and charge-coupled device for wavelength-resolved emission detection. Applying signal integration over a 30-nm emission wavelength interval, signal-to-noise ratios for derivatized amino acids were up to 23 times higher as obtained using a standard photomultiplier for detection. The background electrolyte composition (electrolyte, pH, sodium dodecyl sulfate concentration, and organic solvent) was studied in order to attain optimal chemo- and enantioseparation. Enantioseparation of twelve proteinogenic dl-amino acids was achieved with chiral resolutions between 1.2 and 7.9, and detection limits for most derivatized amino acids in the 13-60 nM range (injected concentration). Linearity (coefficients of determination > 0.985) and peak-area and migration-time repeatabilities (relative standard deviations lower than 2.6 and 1.9%, respectively) were satisfactory. The employed fluorescence detection system provided up to 100-times better signal-to-noise ratios for (+)-1-(9-fluorenyl)ethyl chloroformate-amino acids than ultraviolet absorbance detection, showing good potential for d-amino acid analysis. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  4. Analysis of hydroxamate siderophores in soil solution using liquid chromatography with mass spectrometry and tandem mass spectrometry with on-line sample preconcentration.

    Science.gov (United States)

    Olofsson, Madelen A; Bylund, Dan

    2015-10-01

    A liquid chromatography with electrospray ionization mass spectrometry method was developed to quantitatively and qualitatively analyze 13 hydroxamate siderophores (ferrichrome, ferrirubin, ferrirhodin, ferrichrysin, ferricrocin, ferrioxamine B, D1 , E and G, neocoprogen I and II, coprogen and triacetylfusarinine C). Samples were preconcentrated on-line by a switch-valve setup prior to analyte separation on a Kinetex C18 column. Gradient elution was performed using a mixture of an ammonium formate buffer and acetonitrile. Total analysis time including column conditioning was 20.5 min. Analytes were fragmented by applying collision-induced dissociation, enabling structural identification by tandem mass spectrometry. Limit of detection values for the selected ion monitoring method ranged from 71 pM to 1.5 nM with corresponding values of two to nine times higher for the multiple reaction monitoring method. The liquid chromatography with mass spectrometry method resulted in a robust and sensitive quantification of hydroxamate siderophores as indicated by retention time stability, linearity, sensitivity, precision and recovery. The analytical error of the methods, assessed through random-order, duplicate analysis of soil samples extracted with a mixture of 10 mM phosphate buffer and methanol, appears negligible in relation to between-sample variations. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Scanning transmission ion microscopy mass measurements for quantitative trace element analysis within biological samples and validation using atomic force microscopy thickness measurements

    Energy Technology Data Exchange (ETDEWEB)

    Deves, Guillaume [Laboratoire de chimie nucleaire analytique et bioenvironnementale, UMR 5084, CNRS-Universite de Bordeaux 1, BP 120 Chemin du solarium, F33175 Gradignan cedex (France)]. E-mail: deves@cenbg.in2p3.fr; Cohen-Bouhacina, Touria [Centre de Physique Moleculaire Optique et Hertzienne, Universite de Bordeaux 1, 351, cours de la Liberation, F33405 Talence cedex (France); Ortega, Richard [Laboratoire de chimie nucleaire analytique et bioenvironnementale, UMR 5084, CNRS-Universite de Bordeaux 1, BP 120 Chemin du solarium, F33175 Gradignan cedex (France)

    2004-10-08

    We used the nuclear microprobe techniques, micro-PIXE (particle-induced X-ray emission), micro-RBS (Rutherford backscattering spectrometry) and scanning transmission ion microscopy (STIM) in order to perform the characterization of trace element content and spatial distribution within biological samples (dehydrated cultured cells, tissues). The normalization of PIXE results was usually expressed in terms of sample dry mass as determined by micro-RBS recorded simultaneously to micro-PIXE. However, the main limit of RBS mass measurement is the sample mass loss occurring during irradiation and which could be up to 30% of the initial sample mass. We present here a new methodology for PIXE normalization and quantitative analysis of trace element within biological samples based on dry mass measurement performed by mean of STIM. The validation of STIM cell mass measurements was obtained in comparison with AFM sample thickness measurements. Results indicated the reliability of STIM mass measurement performed on biological samples and suggested that STIM should be performed for PIXE normalization. Further information deriving from direct confrontation of AFM and STIM analysis could as well be obtained, like in situ measurements of cell specific gravity within cells compartment (nucleolus and cytoplasm)

  6. Inorganic mass spectrometry of solid samples

    International Nuclear Information System (INIS)

    Adams, F.; Vertes, A.

    1990-01-01

    In this review some recent developments in the field of inorganic mass spectrometry of solids are described with special emphasis on the actual state of understanding of the ionization processes. It concentrates on the common characteristics of methods such as spark source-, laser-, secondary ion-, inductively coupled plasma- and glow discharge mass spectrometry. (orig.)

  7. Real-time viscosity and mass density sensors requiring microliter sample volume based on nanomechanical resonators.

    Science.gov (United States)

    Bircher, Benjamin A; Duempelmann, Luc; Renggli, Kasper; Lang, Hans Peter; Gerber, Christoph; Bruns, Nico; Braun, Thomas

    2013-09-17

    A microcantilever based method for fluid viscosity and mass density measurements with high temporal resolution and microliter sample consumption is presented. Nanomechanical cantilever vibration is driven by photothermal excitation and detected by an optical beam deflection system using two laser beams of different wavelengths. The theoretical framework relating cantilever response to the viscosity and mass density of the surrounding fluid was extended to consider higher flexural modes vibrating at high Reynolds numbers. The performance of the developed sensor and extended theory was validated over a viscosity range of 1-20 mPa·s and a corresponding mass density range of 998-1176 kg/m(3) using reference fluids. Separating sample plugs from the carrier fluid by a two-phase configuration in combination with a microfluidic flow cell, allowed samples of 5 μL to be sequentially measured under continuous flow, opening the method to fast and reliable screening applications. To demonstrate the study of dynamic processes, the viscosity and mass density changes occurring during the free radical polymerization of acrylamide were monitored and compared to published data. Shear-thinning was observed in the viscosity data at higher flexural modes, which vibrate at elevated frequencies. Rheokinetic models allowed the monomer-to-polymer conversion to be tracked in spite of the shear-thinning behavior, and could be applied to study the kinetics of unknown processes.

  8. Improved analytical sensitivity for uranium and plutonium in environmental samples: Cavity ion source thermal ionization mass spectrometry

    International Nuclear Information System (INIS)

    Ingeneri, Kristofer; Riciputi, L.

    2001-01-01

    Following successful field trials, environmental sampling has played a central role as a routine part of safeguards inspections since early 1996 to verify declared and to detect undeclared activity. The environmental sampling program has brought a new series of analytical challenges, and driven a need for advances in verification technology. Environmental swipe samples are often extremely low in concentration of analyte (ng level or lower), yet the need to analyze these samples accurately and precisely is vital, particularly for the detection of undeclared nuclear activities. Thermal ionization mass spectrometry (TIMS) is the standard method of determining isotope ratios of uranium and plutonium in the environmental sampling program. TIMS analysis typically employs 1-3 filaments to vaporize and ionize the sample, and the ions are mass separated and analyzed using magnetic sector instruments due to their high mass resolution and high ion transmission. However, the ionization efficiency (the ratio of material present to material actually detected) of uranium using a standard TIMS instrument is low (0.2%), even under the best conditions. Increasing ionization efficiency by even a small amount would have a dramatic impact for safeguards applications, allowing both improvements in analytical precision and a significant decrease in the amount of uranium and plutonium required for analysis, increasing the sensitivity of environmental sampling

  9. Automated, feature-based image alignment for high-resolution imaging mass spectrometry of large biological samples

    NARCIS (Netherlands)

    Broersen, A.; Liere, van R.; Altelaar, A.F.M.; Heeren, R.M.A.; McDonnell, L.A.

    2008-01-01

    High-resolution imaging mass spectrometry of large biological samples is the goal of several research groups. In mosaic imaging, the most common method, the large sample is divided into a mosaic of small areas that are then analyzed with high resolution. Here we present an automated alignment

  10. Size selective isocyanate aerosols personal air sampling using porous plastic foams

    International Nuclear Information System (INIS)

    Cong Khanh Huynh; Trinh Vu Duc

    2009-01-01

    As part of a European project (SMT4-CT96-2137), various European institutions specialized in occupational hygiene (BGIA, HSL, IOM, INRS, IST, Ambiente e Lavoro) have established a program of scientific collaboration to develop one or more prototypes of European personal samplers for the collection of simultaneous three dust fractions: inhalable, thoracic and respirable. These samplers based on existing sampling heads (IOM, GSP and cassettes) use Polyurethane Plastic Foam (PUF) according to their porosity to support sampling and separator size of the particles. In this study, the authors present an original application of size selective personal air sampling using chemical impregnated PUF to perform isocyanate aerosols capturing and derivatizing in industrial spray-painting shops.

  11. Sample preparation for accelerator mass spectrometry at the University of Washington

    International Nuclear Information System (INIS)

    Grootes, P.M.; Stuiver, M.; Farwell, G.W.; Schmidt, F.H.

    1981-01-01

    The adaptation of the University of Washington FN tandem Van de Graaff to accelerator mass spectrometry (AMS), as well as some of the results obtained, are described in another paper in this volume (Farwell et al., 1981). Here we discuss our experiences in preparing carbon and beryllium samples that give large and stable ion beams when used in our Extrion cesium sputter source with an inverted cesium beam geometry

  12. Test Sample for the Spatially Resolved Quantification of Illicit Drugs on Fingerprints Using Imaging Mass Spectrometry

    NARCIS (Netherlands)

    Muramoto, S.; Forbes, T.P.; van Asten, A.C.; Gillen, G.

    2015-01-01

    A novel test sample for the spatially resolved quantification of illicit drugs on the surface of a fingerprint using time-of-flight secondary ion mass spectrometry (ToF-SIMS) and desorption electrospray ionization mass spectrometry (DESI-MS) was demonstrated. Calibration curves relating the signal

  13. Time‐of‐flight secondary ion mass spectrometry imaging of biological samples with delayed extraction for high mass and high spatial resolutions

    Science.gov (United States)

    Vanbellingen, Quentin P.; Elie, Nicolas; Eller, Michael J.; Della‐Negra, Serge; Touboul, David

    2015-01-01

    Rationale In Time‐of‐Flight Secondary Ion Mass Spectrometry (TOF‐SIMS), pulsed and focused primary ion beams enable mass spectrometry imaging, a method which is particularly useful to map various small molecules such as lipids at the surface of biological samples. When using TOF‐SIMS instruments, the focusing modes of the primary ion beam delivered by liquid metal ion guns can provide either a mass resolution of several thousand or a sub‐µm lateral resolution, but the combination of both is generally not possible. Methods With a TOF‐SIMS setup, a delayed extraction applied to secondary ions has been studied extensively on rat cerebellum sections in order to compensate for the effect of long primary ion bunches. Results The use of a delayed extraction has been proven to be an efficient solution leading to unique features, i.e. a mass resolution up to 10000 at m/z 385.4 combined with a lateral resolution of about 400 nm. Simulations of ion trajectories confirm the experimental determination of optimal delayed extraction and allow understanding of the behavior of ions as a function of their mass‐to‐charge ratio. Conclusions Although the use of a delayed extraction has been well known for many years and is very popular in MALDI, it is much less used in TOF‐SIMS. Its full characterization now enables secondary ion images to be recorded in a single run with a submicron spatial resolution and with a mass resolution of several thousand. This improvement is very useful when analyzing lipids on tissue sections, or rare, precious, or very small size samples. © 2015 The Authors. Rapid Communications in Mass Spectrometry published by John Wiley & Sons Ltd. PMID:26395603

  14. Bioanalysis of underivatized amino acids in non-invasive exhaled breath condensate samples using liquid chromatography coupled with tandem mass spectrometry.

    Science.gov (United States)

    Konieczna, Lucyna; Pyszka, Magdalena; Okońska, Magdalena; Niedźwiecki, Maciej; Bączek, Tomasz

    2018-03-23

    chromatography with hydrophilic interaction with electrospray source coupled to tandem mass spectrometry (LC-HILIC-ESI-MS/MS) method's applicability for biomedical investigations, it was verified and applied to determine amino acids in pediatric patients with leukemia. These tests confirmed that glutamine, arginine, homoarginine, asparagine, histidine, methionine, proline, hydroxyproline, threonine, tyrosine, and valine were present in significantly higher levels in pediatric leukemia patients than in the healthy control group. The developed assay is an attractive alternative to standard analytical methods, because it allows for the non-invasive, fast, sensitive, and reliable analysis of amino acids without derivatization in EBC. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. A dispersive liquid-liquid microextraction based on solidification of floating organic droplet followed by injector port silylation coupled with gas chromatography-tandem mass spectrometry for the determination of nine bisphenols in bottled carbonated beverages.

    Science.gov (United States)

    Mandrah, Kapil; Satyanarayana, G N V; Roy, Somendu Kumar

    2017-12-15

    In the present study, a method has been efficiently developed for the first time to determine nine bisphenol analogues [bisphenol A (BPA), bisphenol C (BPC), bisphenol AF (BPAF), bisphenol E (BPE), bisphenol F (BPF), bisphenol G (BPG), bisphenol M (BPM), bisphenol S (BPS), and bisphenol Z (BPZ)] together in bottled carbonated beverages (collected from the local market of Lucknow, India) using dispersive liquid-liquid microextraction process. This is based on solidification of floating organic droplet (DLLME-SFO) followed by injector port silylation coupled with gas chromatography-tandem mass spectrometry. The process investigated parameters of DLLME-SFO (including the type of extraction and disperser solvents with their volumes, effect of pH, ionic strength, and the sample volume), factors influencing to injection port derivatization like, collision energy, injector port temperature, derivatizing reagent with sample injection volume, and type of organic solvent. BPA, BPF, BPZ, and BPS were detected in each sample; whereas, other bisphenols were also detected in some carbonated beverage samples. After optimizing the required conditions, good linearity of analytes was achieved in the range of 0.097-100ngmL -1 with coefficients of determination (R 2 )≥0.995. Intra-day and inter day precision of the method was good, with relative standard deviation (% RSD)≤10.95%. The limits of detection (LOD) and limits of quantification (LOQ) values of all bisphenols were ranged from 0.021 to 0.104ngmL -1 and 0.070 to 0.343ngmL -1 , respectively. The recovery of extraction was good (73.15-95.08%) in carbonated beverage samples and good enrichment factors (96.36-117.33) were found. Thus, the developed method of microextraction was highly precise, fast, and reproducible to determine the level of contaminants in bottled carbonated beverages. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Radiocarbon accelerator mass spectrometry (AMS) sample preparation laboratory in Brazil

    International Nuclear Information System (INIS)

    Macario, Kita D.; Gomes, Paulo R. S.; Anjos, Roberto M. dos; Linares, Roberto; Queiroz, Eduardo; Oliveira, Fabiana M. de; Cardozo, Laio; Carvalho, Carla R.A.

    2011-01-01

    Full text: For decades Accelerator Mass Spectrometry has been widely used for radiocarbon measurements all over the world with application in several fields of science from archaeology to geosciences. This technique provides ultrasensitive analysis of reduced size samples or even specific compounds since sample atoms are accelerated to high energies and measured using nuclear particle detectors. Sample preparation is extremely important for accurate radiocarbon measurement and includes chemical pre-treatment to remove all possible contaminants. For beam extraction in the accelerator ion source, samples are usually converted to graphite. In this work we report a new radiocarbon sample preparation facility installed at the Physics Institute of Universidade Federal Fluminense (UFF), in Brazil. At the Nuclear Chronology Laboratory (LACRON) samples are chemically treated and converted to carbon dioxide by hydrolysis or combustion. A stainless steel based vacuum line was constructed for carbon dioxide separation and graphitization is performed in sealed quartz tubes in a muffle oven. Successful graphite production is important to provide stable beam currents and to minimize isotopic fractionation. Performance tests for graphite production are currently under way and isotopic analysis will soon be possible with the acquisition of a Single Stage AMS System by our group. The Single Stage Accelerator produced by National Electrostatic Corporation is a 250 kV air insulated accelerator especially constructed to measure the amount of 14 C in small modern graphite samples to a precision of 0.3 % or better. With the installation of such equipment in the first half of 2012, UFF will be ready to perform the 14C -AMS technique. (author)

  17. Analysis of U and Pu resin bead samples with a single stage mass spectrometer

    International Nuclear Information System (INIS)

    Smith, D.H.; Walker, R.L.; Bertram, L.K.; Carter, J.A.

    1979-01-01

    Resin bead sampling enables the shipment of nanogram U and Pu quantities for analysis. Application of this sampling technique to safeguards was investigated with a single-stage mass spectrometer. Standards gave results in good agreement with NBS certified values. External precisions of +-0.5% were obtained on isotopic ratios of approx. 0.01; precisions on quantitative measurements are +-1.0%

  18. Cluster chemical ionization for improved confidence level in sample identification by gas chromatography/mass spectrometry.

    Science.gov (United States)

    Fialkov, Alexander B; Amirav, Aviv

    2003-01-01

    Upon the supersonic expansion of helium mixed with vapor from an organic solvent (e.g. methanol), various clusters of the solvent with the sample molecules can be formed. As a result of 70 eV electron ionization of these clusters, cluster chemical ionization (cluster CI) mass spectra are obtained. These spectra are characterized by the combination of EI mass spectra of vibrationally cold molecules in the supersonic molecular beam (cold EI) with CI-like appearance of abundant protonated molecules, together with satellite peaks corresponding to protonated or non-protonated clusters of sample compounds with 1-3 solvent molecules. Like CI, cluster CI preferably occurs for polar compounds with high proton affinity. However, in contrast to conventional CI, for non-polar compounds or those with reduced proton affinity the cluster CI mass spectrum converges to that of cold EI. The appearance of a protonated molecule and its solvent cluster peaks, plus the lack of protonation and cluster satellites for prominent EI fragments, enable the unambiguous identification of the molecular ion. In turn, the insertion of the proper molecular ion into the NIST library search of the cold EI mass spectra eliminates those candidates with incorrect molecular mass and thus significantly increases the confidence level in sample identification. Furthermore, molecular mass identification is of prime importance for the analysis of unknown compounds that are absent in the library. Examples are given with emphasis on the cluster CI analysis of carbamate pesticides, high explosives and unknown samples, to demonstrate the usefulness of Supersonic GC/MS (GC/MS with supersonic molecular beam) in the analysis of these thermally labile compounds. Cluster CI is shown to be a practical ionization method, due to its ease-of-use and fast instrumental conversion between EI and cluster CI, which involves the opening of only one valve located at the make-up gas path. The ease-of-use of cluster CI is analogous

  19. Analysis of Frankincense in Archaeological Samples by Gas Chromatography-Mass Spectrometry

    International Nuclear Information System (INIS)

    Mathe, C.; Archier, P.; Vieillescazes, C.; Connan, J.; Mouton, M.

    2007-01-01

    Four archaeological samples, unearthed from Qana in Yemen were analysed by analytical technique, currently applied in the field of petroleum geochemistry, and by gas chromatography coupled with a mass spectrometer (GC-MS). Sample no 1286 comes from a burned warehouse and samples no 964, 963 and 962 from the central sanctuary. These specimens were probably exposed to a heating source. In each case olibanum resin was identified according to the presence of their chemical markers corresponding to α-, β-boswellic and lupeolic acids (3α-hydroxy-olean-12-en-24-oic, 3α-hydroxy-urs-12-en-24-oic and 3α-hydroxy-lup-20(29)en-24-oic acids) and their respective O-acetyled derivatives (3α- O-acetyl -olean-12-en-24-oic, 3α-O-acetyl-urs-12-en-24-oic and 3α-O-acetyl-lup-20(29)-en-24-oic acids). Concerning the thermal degradation state of samples, the GC-MS results are in agreement with the geochemical ones. Sample no 1286 and 964 correspond to ageing incense which has not undergone any heating action and are consequently relatively well preserved. Lastly, samples no 963 and 962 are thermally degraded resins and their gross composition data permits to conclude that sample no 963 is only partially burnt while sample no 962 has been much more degraded

  20. Isotope dilution/mass spectrometry of serum cholesterol with [3,4-13C]cholesterol: proposed definitive method

    International Nuclear Information System (INIS)

    Pelletier, O.; Wright, L.A.; Breckenridge, W.C.

    1987-01-01

    We describe a new gas-chromatographic/mass-spectrometric (GC/MS) isotope-dilution method for determination of serum cholesterol. The method has been fully optimized and documented to provide the high accuracy and precision expected for a Definitive Method. In the presence of [3,4- 13 C]cholesterol, cholesteryl esters in serum are hydrolyzed under optimum conditions and the entire cholesterol pool is extracted and derivatized to silyl ethers. The cholesterol derivatives are resolved from other sterols by gas-liquid chromatography on a fused silica column, and selected ions characteristic of cholesterol and the [3,4- 13 C]cholesterol are monitored with a GC/MS quandrupole system. We estimated the cholesterol content of samples by bracketing each sample with standards of comparable cholesterol concentration that also contained the [3,4- 13 C]cholesterol. The procedure was highly reproducible (CV less than 0.5%), better accuracy and precision being obtained with [3,4- 13 C]cholesterol than with heptadeuterated cholesterol. Mean values per gram of dry serum for one serum pool assayed by this method and that of the National Bureau of Standards differed by 0.5%. We conclude that the method satisfies the criteria for a Definitive Method