WorldWideScience

Sample records for sample collection period

  1. Urine sample collection protocols for bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject`s body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  2. Urine sample collection protocols for bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject's body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  3. Sample collection and documentation

    International Nuclear Information System (INIS)

    Cullings, Harry M.; Fujita, Shoichiro; Watanabe, Tadaaki; Yamashita, Tomoaki; Tanaka, Kenichi; Endo, Satoru; Shizuma, Kiyoshi; Hoshi, Masaharu; Hasai, Hiromi

    2005-01-01

    Beginning within a few weeks after the bombings and periodically during the intervening decades, investigators in Hiroshima and Nagasaki have collected samples of materials that were in the cities at the time of the bombings. Although some early efforts were not driven by specific measurement objectives, many others were. Even some of the very earliest samples collected in 1945 were based on carefully conceived research plans and detailed specifications for samples appropriate to particular retrospective measurements, i.e., of particular residual quantities remaining from exposure to the neutrons and gamma rays from the bombs. This chapter focuses mainly on the work of groups at two institutions that have actively collaborated since the 1980s in major collection efforts and have shared samples among themselves and with other investigators: the Radiation Effects Research Foundation (RERF) and its predecessor the Atomic Bomb Casualty Commission (ABCC), and Hiroshima University. In addition, a number of others are listed, who also contributed to the literature by their collection of samples. (J.P.N.)

  4. k0-INAA for APM samples collected in period of June 2004 - March 2005 and some marine certified reference materials

    International Nuclear Information System (INIS)

    Dung, Ho Manh; Vu, Cao Dong; Y, Truong; Sy, Nguyen Thi

    2006-01-01

    The airborne particulate matter (APM) samples have been collected in 2004 using two types of polycarbonate membrane filter PM 2.5 and PM 2.5-10 at two sites of industrial (Ho Chi Mihn City) and rural (Dateh) regions in south of Vietnam. Three marine certified reference materials have been selected to establish a k0-NAA procedure for marine samples. The concentration of trace multi-element in the samples has been determined by the k 0 -INAA procedure using K o -DALAT software developed in Dalat NRI. About 28 elements in 224 APM samples collected at two areas of Dateh and HCMC of Vietnam in period from June, 2004 to March, 2005 were presented in report. The statistical analysis was applied to the data set to investigate the pollution source at sampling sites. The results proved that the k 0 -NAA on the Dalat research reactor is a reliable and effective analytical technique for characterization of trace multi-element in APM and marine samples for air and marine environmental pollution study in Vietnam. (author)

  5. Biopolymers for sample collection, protection, and preservation.

    Science.gov (United States)

    Sorokulova, Iryna; Olsen, Eric; Vodyanoy, Vitaly

    2015-07-01

    One of the principal challenges in the collection of biological samples from air, water, and soil matrices is that the target agents are not stable enough to be transferred from the collection point to the laboratory of choice without experiencing significant degradation and loss of viability. At present, there is no method to transport biological samples over considerable distances safely, efficiently, and cost-effectively without the use of ice or refrigeration. Current techniques of protection and preservation of biological materials have serious drawbacks. Many known techniques of preservation cause structural damages, so that biological materials lose their structural integrity and viability. We review applications of a novel bacterial preservation process, which is nontoxic and water soluble and allows for the storage of samples without refrigeration. The method is capable of protecting the biological sample from the effects of environment for extended periods of time and then allows for the easy release of these collected biological materials from the protective medium without structural or DNA damage. Strategies for sample collection, preservation, and shipment of bacterial, viral samples are described. The water-soluble polymer is used to immobilize the biological material by replacing the water molecules within the sample with molecules of the biopolymer. The cured polymer results in a solid protective film that is stable to many organic solvents, but quickly removed by the application of the water-based solution. The process of immobilization does not require the use of any additives, accelerators, or plastifiers and does not involve high temperature or radiation to promote polymerization.

  6. Groundwater-quality data in 12 GAMA study units: Results from the 2006–10 initial sampling period and the 2008–13 trend sampling period, California GAMA Priority Basin Project

    Science.gov (United States)

    Mathany, Timothy M.

    2017-03-09

    The Priority Basin Project (PBP) of the Groundwater Ambient Monitoring and Assessment (GAMA) program was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey in cooperation with the California State Water Resources Control Board. From 2004 through 2012, the GAMA-PBP collected samples and assessed the quality of groundwater resources that supply public drinking water in 35 study units across the State. Selected sites in each study unit were sampled again approximately 3 years after initial sampling as part of an assessment of temporal trends in water quality by the GAMA-PBP. Twelve of the study units, initially sampled during 2006–11 (initial sampling period) and sampled a second time during 2008–13 (trend sampling period) to assess temporal trends, are the subject of this report.The initial sampling was designed to provide a spatially unbiased assessment of the quality of untreated groundwater used for public water supplies in the 12 study units. In these study units, 550 sampling sites were selected by using a spatially distributed, randomized, grid-based method to provide spatially unbiased representation of the areas assessed (grid sites, also called “status sites”). After the initial sampling period, 76 of the previously sampled status sites (approximately 10 percent in each study unit) were randomly selected for trend sampling (“trend sites”). The 12 study units sampled both during the initial sampling and during the trend sampling period were distributed among 6 hydrogeologic provinces: Coastal (Northern and Southern), Transverse Ranges and Selected Peninsular Ranges, Klamath, Modoc Plateau and Cascades, and Sierra Nevada Hydrogeologic Provinces. For the purposes of this trend report, the six hydrogeologic provinces were grouped into two hydrogeologic regions based on location: Coastal and Mountain.The groundwater samples were analyzed for a number of synthetic organic

  7. Biopolymers for Sample Collection, Protection, and Preservation

    Science.gov (United States)

    2015-05-19

    knowledge of sample collection from various matrices is crucial. Recovery and preservation of microorganisms prior to analysis are important...Another method for encapsulating bacteria for use in biodegradation of gasoline involves a complex process using gellan gum (Moslemy et al. 2002). Many...use of acacia gum in preserving microorganisms for extended periods of time without refrigeration (Krumnow et al. 2009; Sorokulova et al. 2008, 2012

  8. Fluid sample collection and distribution system. [qualitative analysis of aqueous samples from several points

    Science.gov (United States)

    Brooks, R. L. (Inventor)

    1979-01-01

    A multipoint fluid sample collection and distribution system is provided wherein the sample inputs are made through one or more of a number of sampling valves to a progressive cavity pump which is not susceptible to damage by large unfiltered particles. The pump output is through a filter unit that can provide a filtered multipoint sample. An unfiltered multipoint sample is also provided. An effluent sample can be taken and applied to a second progressive cavity pump for pumping to a filter unit that can provide one or more filtered effluent samples. The second pump can also provide an unfiltered effluent sample. Means are provided to periodically back flush each filter unit without shutting off the whole system.

  9. Importance of sampling frequency when collecting diatoms

    KAUST Repository

    Wu, Naicheng

    2016-11-14

    There has been increasing interest in diatom-based bio-assessment but we still lack a comprehensive understanding of how to capture diatoms’ temporal dynamics with an appropriate sampling frequency (ASF). To cover this research gap, we collected and analyzed daily riverine diatom samples over a 1-year period (25 April 2013–30 April 2014) at the outlet of a German lowland river. The samples were classified into five clusters (1–5) by a Kohonen Self-Organizing Map (SOM) method based on similarity between species compositions over time. ASFs were determined to be 25 days at Cluster 2 (June-July 2013) and 13 days at Cluster 5 (February-April 2014), whereas no specific ASFs were found at Cluster 1 (April-May 2013), 3 (August-November 2013) (>30 days) and Cluster 4 (December 2013 - January 2014) (<1 day). ASFs showed dramatic seasonality and were negatively related to hydrological wetness conditions, suggesting that sampling interval should be reduced with increasing catchment wetness. A key implication of our findings for freshwater management is that long-term bio-monitoring protocols should be developed with the knowledge of tracking algal temporal dynamics with an appropriate sampling frequency.

  10. OSIRIS-REx Touch-and-Go (TAG) Mission Design for Asteroid Sample Collection

    Science.gov (United States)

    May, Alexander; Sutter, Brian; Linn, Timothy; Bierhaus, Beau; Berry, Kevin; Mink, Ron

    2014-01-01

    The Origins Spectral Interpretation Resource Identification Security Regolith Explorer (OSIRIS-REx) mission is a NASA New Frontiers mission launching in September 2016 to rendezvous with the near-Earth asteroid Bennu in October 2018. After several months of proximity operations to characterize the asteroid, OSIRIS-REx flies a Touch-And-Go (TAG) trajectory to the asteroid's surface to collect at least 60 g of pristine regolith sample for Earth return. This paper provides mission and flight system overviews, with more details on the TAG mission design and key events that occur to safely and successfully collect the sample. An overview of the navigation performed relative to a chosen sample site, along with the maneuvers to reach the desired site is described. Safety monitoring during descent is performed with onboard sensors providing an option to abort, troubleshoot, and try again if necessary. Sample collection occurs using a collection device at the end of an articulating robotic arm during a brief five second contact period, while a constant force spring mechanism in the arm assists to rebound the spacecraft away from the surface. Finally, the sample is measured quantitatively utilizing the law of conservation of angular momentum, along with qualitative data from imagery of the sampling device. Upon sample mass verification, the arm places the sample into the Stardust-heritage Sample Return Capsule (SRC) for return to Earth in September 2023.

  11. PERIOD ESTIMATION FOR SPARSELY SAMPLED QUASI-PERIODIC LIGHT CURVES APPLIED TO MIRAS

    Energy Technology Data Exchange (ETDEWEB)

    He, Shiyuan; Huang, Jianhua Z.; Long, James [Department of Statistics, Texas A and M University, College Station, TX (United States); Yuan, Wenlong; Macri, Lucas M., E-mail: lmacri@tamu.edu [George P. and Cynthia W. Mitchell Institute for Fundamental Physics and Astronomy, Department of Physics and Astronomy, Texas A and M University, College Station, TX (United States)

    2016-12-01

    We develop a nonlinear semi-parametric Gaussian process model to estimate periods of Miras with sparsely sampled light curves. The model uses a sinusoidal basis for the periodic variation and a Gaussian process for the stochastic changes. We use maximum likelihood to estimate the period and the parameters of the Gaussian process, while integrating out the effects of other nuisance parameters in the model with respect to a suitable prior distribution obtained from earlier studies. Since the likelihood is highly multimodal for period, we implement a hybrid method that applies the quasi-Newton algorithm for Gaussian process parameters and search the period/frequency parameter space over a dense grid. A large-scale, high-fidelity simulation is conducted to mimic the sampling quality of Mira light curves obtained by the M33 Synoptic Stellar Survey. The simulated data set is publicly available and can serve as a testbed for future evaluation of different period estimation methods. The semi-parametric model outperforms an existing algorithm on this simulated test data set as measured by period recovery rate and quality of the resulting period–luminosity relations.

  12. Equipment for collecting samples of radioactive solutions

    International Nuclear Information System (INIS)

    Raggenbass, A.; Fradin, J.; Joubert, G.

    1958-01-01

    The authors present an equipment aimed at collecting samples of fission products to perform radio-chemical analysis. As the sample must have a total activity between 1 and 50 micro-Curie, this installation comprises a sampling system and a dilution device which aims at bringing the sample to the suitable activity. Samples are collected by means of needles. The sample reproducibility is discussed. The dilution device is described

  13. Portable automation of static chamber sample collection for quantifying soil gas flux

    Science.gov (United States)

    The collection of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled in a given time period is limited by the spacing between chambers and the availability of trained research technicians. However, the static chamber method can limit spatial ...

  14. Analysis of the research sample collections of Uppsala biobank.

    Science.gov (United States)

    Engelmark, Malin T; Beskow, Anna H

    2014-10-01

    Uppsala Biobank is the joint and only biobank organization of the two principals, Uppsala University and Uppsala University Hospital. Biobanks are required to have updated registries on sample collection composition and management in order to fulfill legal regulations. We report here the results from the first comprehensive and overall analysis of the 131 research sample collections organized in the biobank. The results show that the median of the number of samples in the collections was 700 and that the number of samples varied from less than 500 to over one million. Blood samples, such as whole blood, serum, and plasma, were included in the vast majority, 84.0%, of the research sample collections. Also, as much as 95.5% of the newly collected samples within healthcare included blood samples, which further supports the concept that blood samples have fundamental importance for medical research. Tissue samples were also commonly used and occurred in 39.7% of the research sample collections, often combined with other types of samples. In total, 96.9% of the 131 sample collections included samples collected for healthcare, showing the importance of healthcare as a research infrastructure. Of the collections that had accessed existing samples from healthcare, as much as 96.3% included tissue samples from the Department of Pathology, which shows the importance of pathology samples as a resource for medical research. Analysis of different research areas shows that the most common of known public health diseases are covered. Collections that had generated the most publications, up to over 300, contained a large number of samples collected systematically and repeatedly over many years. More knowledge about existing biobank materials, together with public registries on sample collections, will support research collaborations, improve transparency, and bring us closer to the goals of biobanks, which is to save and prolong human lives and improve health and quality of life.

  15. 28 CFR 28.12 - Collection of DNA samples.

    Science.gov (United States)

    2010-07-01

    ... Homeland Security, collecting DNA samples from: (1) Aliens lawfully in, or being processed for lawful... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Collection of DNA samples. 28.12 Section 28.12 Judicial Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample Collection...

  16. Collecting Ground Samples for Balloon-Borne Instruments

    Science.gov (United States)

    Jones, Jack; Zimmerman, Wayne; Wu, Jiunn Jenq

    2009-01-01

    A proposed system in a gondola containing scientific instruments suspended by a balloon over the surface of the Saturn moon Titan would quickly acquire samples of rock or ice from the ground below. Prototypes of a sample-collecting device that would be a major part of the system have been tested under cryogenic and non-cryogenic conditions on Earth. Systems like this one could also be used in non-cryogenic environments on Earth to collect samples of rock, soil, ice, mud, or other ground material from such inaccessible or hazardous locations as sites of suspected chemical spills or biological contamination. The sample-collecting device would be a harpoonlike device that would be connected to the balloon-borne gondola by a tether long enough to reach the ground. The device would be dropped from the gondola to acquire a sample, then would be reeled back up to the gondola, where the sample would be analyzed by the onboard instruments. Each prototype of the sample-collecting device has a sharp front (lower) end, a hollow core for retaining a sample, a spring for holding the sample in the hollow core, and a rear (upper) annular cavity for retaining liquid sample material. Aerodynamic fins at the rear help to keep the front end pointed downward. In tests, these prototype devices were dropped from various heights and used to gather samples of dry sand, moist sand, cryogenic water ice, and warmer water ice.

  17. The Apollo lunar samples collection analysis and results

    CERN Document Server

    Young, Anthony

    2017-01-01

    This book focuses on the specific mission planning for lunar sample collection, the equipment used, and the analysis and findings concerning the samples at the Lunar Receiving Laboratory in Texas. Anthony Young documents the collection of Apollo samples for the first time for readers of all backgrounds, and includes interviews with many of those involved in planning and analyzing the samples. NASA contracted with the U.S. Geologic Survey to perform classroom and field training of the Apollo astronauts. NASA’s Geology Group within the Manned Spacecraft Center in Houston, Texas, helped to establish the goals of sample collection, as well as the design of sample collection tools, bags, and storage containers. In this book, detailed descriptions are given on the design of the lunar sampling tools, the Modular Experiment Transporter used on Apollo 14, and the specific areas of the Lunar Rover vehicle used for the Apollo 15, 16, and 17 missions, which carried the sampling tools, bags, and other related equipment ...

  18. Evaluating the optimum rest period prior to blood collection for fractionated plasma free metanephrines analysis

    LENUS (Irish Health Repository)

    Griffin, T.P.

    2016-05-01

    The high diagnostic accuracy of plasma metanephrines (PMets) in the di-agnosis of Phaeochromocytoma\\/Paraganglioma (PPGL) is well established. Considerable controversy exists regarding optimum sampling conditions for PMets. The use of reference intervals that do not compromise diagnostic sensitivity is recommended. However, the optimum rest period prior to sampling has yet to be clearly established. The aim of this study was to evaluate PMets concentrations in paired blood samples collected following 30 and 40 min seated-rest prior to sampling, in patients in whom it was clinically rea-sonable to suspect that PPGL may be present.

  19. The development of a Martian atmospheric Sample collection canister

    Science.gov (United States)

    Kulczycki, E.; Galey, C.; Kennedy, B.; Budney, C.; Bame, D.; Van Schilfgaarde, R.; Aisen, N.; Townsend, J.; Younse, P.; Piacentine, J.

    The collection of an atmospheric sample from Mars would provide significant insight to the understanding of the elemental composition and sub-surface out-gassing rates of noble gases. A team of engineers at the Jet Propulsion Laboratory (JPL), California Institute of Technology have developed an atmospheric sample collection canister for Martian application. The engineering strategy has two basic elements: first, to collect two separately sealed 50 cubic centimeter unpressurized atmospheric samples with minimal sensing and actuation in a self contained pressure vessel; and second, to package this atmospheric sample canister in such a way that it can be easily integrated into the orbiting sample capsule for collection and return to Earth. Sample collection and integrity are demonstrated by emulating the atmospheric collection portion of the Mars Sample Return mission on a compressed timeline. The test results achieved by varying the pressure inside of a thermal vacuum chamber while opening and closing the valve on the sample canister at Mars ambient pressure. A commercial off-the-shelf medical grade micro-valve is utilized in the first iteration of this design to enable rapid testing of the system. The valve has been independently leak tested at JPL to quantify and separate the leak rates associated with the canister. The results are factored in to an overall system design that quantifies mass, power, and sensing requirements for a Martian atmospheric Sample Collection (MASC) canister as outlined in the Mars Sample Return mission profile. Qualitative results include the selection of materials to minimize sample contamination, preliminary science requirements, priorities in sample composition, flight valve selection criteria, a storyboard from sample collection to loading in the orbiting sample capsule, and contributions to maintaining “ Earth” clean exterior surfaces on the orbiting sample capsule.

  20. Collection and preparation of samples for Agency's programme of intercalibration methods and procedures for measurement of environmental radioactivity

    International Nuclear Information System (INIS)

    Patel, B.

    1975-12-01

    In the period of 1971-1975 several samples of marine sediment and organisms were collected from the Bombay Harbour Bay as well as from the vicinity of the Tarapur nuclear power station in order to supply the materials for preparing intercalibration samples for radionuclides measurements. All samples collected were freeze-dried and homogenized prior to the dispatch to the Monaco Laboratory, where final homogenization and the homogeneity tests were carried out. Altogether 2 marine organisms and 3 marine sediments were supplied during this period. The materials supplied were proved to be useful to prepare intercalibration samples for radionuclide measurements in the levels for monitoring operations. Based on these materials several intercalibration exercises were successfully conducted. This work thus formed a basis for bringing the better comparability of radionuclide measurements in marine environmental samples in an international scale

  1. The U.S. Geological Survey Geologic Collections Management System (GCMS)—A master catalog and collections management plan for U.S. Geological Survey geologic samples and sample collections

    Science.gov (United States)

    ,

    2015-01-01

    The U.S. Geological Survey (USGS) is widely recognized in the earth science community as possessing extensive collections of earth materials collected by research personnel over the course of its history. In 2006, a Geologic Collections Inventory was conducted within the USGS Geology Discipline to determine the extent and nature of its sample collections, and in 2008, a working group was convened by the USGS National Geologic and Geophysical Data Preservation Program to examine ways in which these collections could be coordinated, cataloged, and made available to researchers both inside and outside the USGS. The charge to this working group was to evaluate the proposition of creating a Geologic Collections Management System (GCMS), a centralized database that would (1) identify all existing USGS geologic collections, regardless of size, (2) create a virtual link among the collections, and (3) provide a way for scientists and other researchers to obtain access to the samples and data in which they are interested. Additionally, the group was instructed to develop criteria for evaluating current collections and to establish an operating plan and set of standard practices for handling, identifying, and managing future sample collections. Policies and procedures promoted by the GCMS would be based on extant best practices established by the National Science Foundation and the Smithsonian Institution. The resulting report—USGS Circular 1410, “The U.S. Geological Survey Geologic Collections Management System (GCMS): A Master Catalog and Collections Management Plan for U.S. Geological Survey Geologic Samples and Sample Collections”—has been developed for sample repositories to be a guide to establishing common practices in the collection, retention, and disposal of geologic research materials throughout the USGS.

  2. A rest period does not affect in vitro storage properties in apheresis platelets collected from the buffy coat layer.

    Science.gov (United States)

    Wagner, Stephen J; Seetharaman, Shalini; Kurtz, James

    2012-11-01

    A previous study demonstrated that several in vitro storage properties of apheresis platelets (PLTs) that are isolated by sedimentation against the collection container and subsequently resuspended can benefit from a rest period before continuous agitation. This study examines whether the in vitro storage properties of apheresis PLTs isolated by collection from the buffy coat layer benefit from a rest period before agitation. Freshly collected apheresis PLTs (Trima, GambroBCT) were divided into five 60-mL aliquots. One aliquot was immediately placed on a flat-bed agitator; the other aliquots were held on a laboratory bench for 1, 2, 4, and 6 hours before continuous agitation. Samples were obtained on Days 1, 5, and 7 for standard in vitro PLT assays. The experiment was repeated 12 times. For each sampling day, no significant differences were observed in aliquots held with or without a rest period for any of the following PLT properties: PLT content, mean PLT volume, pH, pCO2, bicarbonate, glucose, lactate, hypotonic shock response, extent of shape change, aggregation, morphology, CD62P, CD63, and CD42b. Although regression analysis identified several in vitro properties whose mean levels appeared to improve with increasing length of the rest period, maximum differences in mean levels were small (coat layer do not benefit from a rest period. © 2012 American Association of Blood Banks.

  3. Collection of size fractionated particulate matter sample for neutron activation analysis in Japan

    International Nuclear Information System (INIS)

    Otoshi, Tsunehiko; Nakamatsu, Hiroaki; Oura, Yasuji; Ebihara, Mitsuru

    2004-01-01

    According to the decision of the 2001 Workshop on Utilization of Research Reactor (Neutron Activation Analysis (NAA) Section), size fractionated particulate matter collection for NAA was started from 2002 at two sites in Japan. The two monitoring sites, ''Tokyo'' and ''Sakata'', were classified into ''urban'' and ''rural''. In each site, two size fractions, namely PM 2-10 '' and PM 2 '' particles (aerodynamic particle size between 2 to 10 micrometer and less than 2 micrometer, respectively) were collected every month on polycarbonate membrane filters. Average concentrations of PM 10 (sum of PM 2-10 and PM 2 samples) during the common sampling period of August to November 2002 in each site were 0.031mg/m 3 in Tokyo, and 0.022mg/m 3 in Sakata. (author)

  4. Unsupervised Ensemble Anomaly Detection Using Time-Periodic Packet Sampling

    Science.gov (United States)

    Uchida, Masato; Nawata, Shuichi; Gu, Yu; Tsuru, Masato; Oie, Yuji

    We propose an anomaly detection method for finding patterns in network traffic that do not conform to legitimate (i.e., normal) behavior. The proposed method trains a baseline model describing the normal behavior of network traffic without using manually labeled traffic data. The trained baseline model is used as the basis for comparison with the audit network traffic. This anomaly detection works in an unsupervised manner through the use of time-periodic packet sampling, which is used in a manner that differs from its intended purpose — the lossy nature of packet sampling is used to extract normal packets from the unlabeled original traffic data. Evaluation using actual traffic traces showed that the proposed method has false positive and false negative rates in the detection of anomalies regarding TCP SYN packets comparable to those of a conventional method that uses manually labeled traffic data to train the baseline model. Performance variation due to the probabilistic nature of sampled traffic data is mitigated by using ensemble anomaly detection that collectively exploits multiple baseline models in parallel. Alarm sensitivity is adjusted for the intended use by using maximum- and minimum-based anomaly detection that effectively take advantage of the performance variations among the multiple baseline models. Testing using actual traffic traces showed that the proposed anomaly detection method performs as well as one using manually labeled traffic data and better than one using randomly sampled (unlabeled) traffic data.

  5. Portable Automation of Static Chamber Sample Collection for Quantifying Soil Gas Flux

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Morgan P.; Groh, Tyler A.; Parkin, Timothy B.; Williams, Ryan J.; Isenhart, Thomas M.; Hofmockel, Kirsten S.

    2018-01-01

    Quantification of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled is limited by the spacing between chambers and the availability of trained research technicians. An automated system for collecting gas samples from chambers in the field would eliminate the need for personnel to return to the chamber during a flux measurement period and would allow a single technician to sample multiple chambers simultaneously. This study describes Chamber Automated Sampling Equipment (FluxCASE) to collect and store chamber headspace gas samples at assigned time points for the measurement of soil gas flux. The FluxCASE design and operation is described, and the accuracy and precision of the FluxCASE system is evaluated. In laboratory measurements of nitrous oxide (N2O), carbon dioxide (CO2), and methane (CH4) concentrations of a standardized gas mixture, coefficients of variation associated with automated and manual sample collection were comparable, indicating no loss of precision. In the field, soil gas fluxes measured from FluxCASEs were in agreement with manual sampling for both N2O and CO2. Slopes of regression equations were 1.01 for CO2 and 0.97 for N2O. The 95% confidence limits of the slopes of the regression lines included the value of one, indicating no bias. Additionally, an expense analysis found a cost recovery ranging from 0.6 to 2.2 yr. Implementing the FluxCASE system is an alternative to improve the efficiency of the static chamber method for measuring soil gas flux while maintaining the accuracy and precision of manual sampling.

  6. Normalisation of spot urine samples to 24-h collection for assessment of exposure to uranium

    International Nuclear Information System (INIS)

    Marco, R.; Katorza, E.; Gonen, R.; German, U.; Tshuva, A.; Pelled, O.; Paz-tal, O.; Adout, A.; Karpas, Z.

    2008-01-01

    For dose assessment of workers at Nuclear Research Center Negev exposed to natural uranium, spot urine samples are analysed and the results are normalised to 24-h urine excretion based on 'standard' man urine volume of 1.6 l d -1 . In the present work, the urine volume, uranium level and creatinine concentration were determined in two or three 24-h urine collections from 133 male workers (319 samples) and 33 female workers (88 samples). Three volunteers provided urine spot samples from each voiding during a 24-h period and a good correlation was found between the relative level of creatinine and uranium in spot samples collected from the same individual. The results show that normalisation of uranium concentration to creatinine in a spot sample represents the 24-h content of uranium better than normalisation to the standard volume and may be used to reduce the uncertainty of dose assessment based on spot samples. (authors)

  7. Concordance analysis of methylation biomarkers detection in self-collected and physician-collected samples in cervical neoplasm

    International Nuclear Information System (INIS)

    Chang, Cheng-Chang; Huang, Rui-Lan; Liao, Yu-Ping; Su, Po-Hsuan; Hsu, Yaw-Wen; Wang, Hui-Chen; Tien, Chau-Yang; Yu, Mu-Hsien; Lin, Ya-Wen; Lai, Hung-Cheng

    2015-01-01

    Non-attendance at gynecological clinics is a major limitation of cervical cancer screening and self-collection of samples may improve this situation. Although HPV testing of self-collected vaginal samples is acceptable, the specificity is inadequate. The current focus is increasing self-collection of vaginal samples to minimize clinic visits. In this study, we analyzed the concordance and clinical performance of DNA methylation biomarker (PAX1, SOX1, and ZNF582) detection in self-collected vaginal samples and physician-collected cervical samples for the identification of cervical neoplasm. We enrolled 136 cases with paired methylation data identified from abnormal Pap smears (n = 126) and normal controls (n = 10) regardless of HPV status at gynecological clinics. The study group comprised 37 cervical intraepithelial neoplasm I (CIN1), 23 cervical intraepithelial neoplasm II (CIN2), 16 cervical intraepithelial neoplasm III (CIN3), 30 carcinoma in situ (CIS), 13 squamous cell carcinomas (SCCs) and seven adenocarcinomas (ACs)/adenosquamous carcinomas (ASCs). PAX1, SOX1 and ZNF582 methylation in study samples was assessed by real-time quantitative methylation-specific polymerase chain reaction analysis. We generated methylation index cutoff values for the detection of CIN3+ in physician-collected cervical samples for analysis of the self-collected group. Concordance between the physician-collected and self-collected groups was evaluated by Cohen’s Kappa. Sensitivity, specificity and area under curve (AUC) were calculated for detection of CIN3+ lesions. Finally, we produced an optimal cutoff value with the best sensitivity from the self-collected groups. We generated a methylation index cutoff value from physician-collected samples for detection of CIN3+. There were no significant differences in sensitivity, specificity of PAX1, SOX1 and ZNF582 between the self-collected and physician-collected groups. The methylation status of all three genes in the normal control

  8. Evaluation of the Use of Periodicals Collection of the Higher Education Council Documentation and Online Search Center: Arts and Humanities Periodicals

    Directory of Open Access Journals (Sweden)

    Elçin Özbudak

    1995-06-01

    Full Text Available Evaluation of the use perodicals collections in libraries is important as perodicals report the results of the latest scientific research and they are usually more expensive than other types of library materials. In this study we evaluate the use of Arts and Humanities periodicals in the collection of the Higher Education Council Documentation Center. Although the use of Arts and Humanities periodicals was found to be lower than, say, Biomedical periodicals collection, the number of journal titles in Arts and Humanities appears to be quite satisfactory. Some suggestions are made so as to increase the use of Arts and Humanities periodicals collection.

  9. Monitoring of uranium concentrations in water samples collected near potentially hazardous objects in North-West Tajikistan.

    Science.gov (United States)

    Zoriy, P; Schläger, M; Murtazaev, K; Pillath, J; Zoriy, M; Heuel-Fabianek, B

    2018-01-01

    The water contamination near ecologically problematic objects was investigated between 2009 and 2014 in North-West Tajikistan as a part of a joint project between Forschungszentrum Jülich and Khujand State University. The main part of this work was the determination of uranium in water samples collected near the Degmay tailings dump, the Taboshar pit lake and the Syr Darya river. More than 130 water samples were collected and analyzed to monitor the uranium concentration near the investigated areas. Two different mass spectrometers and an ion chromatograph were used for element concentration measurements. Based on the results obtained, the uranium influence of the Degmay tailings on the rivers Khoja-Bakyrgan-Say and Syr Darya and surrounding water was not found. The uranium concentration in water samples was monitored for a lengthy period at seven locations Great differences in the uranium concentration in waters collected in 2010, 2011, 2012, 2013 for each location were not observed. Drinking water samples from the region of North-West Tajikistan were analyzed and compared with the World Health Organization's guidelines. Seven out of nine drinking water samples near Taboshar exceeded the WHO guideline value for uranium concentrations (30 μg/L). The average uranium concentration of water samples from Syr Darya for the period from 2009 to 2014 was determined to be 20.1 (±5.2) μg/L. The uranium contamination of the Syr Darya was determined from the western border to the eastern border and the results are shown in this paper. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Variability and reliability of POP concentrations in multiple breast milk samples collected from the same mothers.

    Science.gov (United States)

    Kakimoto, Risa; Ichiba, Masayoshi; Matsumoto, Akiko; Nakai, Kunihiko; Tatsuta, Nozomi; Iwai-Shimada, Miyuki; Ishiyama, Momoko; Ryuda, Noriko; Someya, Takashi; Tokumoto, Ieyasu; Ueno, Daisuke

    2018-01-13

    Risk assessment of infant using a realistic persistent organic pollutant (POP) exposure through breast milk is essential to devise future regulation of POPs. However, recent investigations have demonstrated that POP levels in breast milk collected from the same mother showed a wide range of variation daily and monthly. To estimate the appropriate sample size of breast milk from the same mother to obtain reliable POP concentrations, breast milk samples were collected from five mothers living in Japan from 2006 to 2012. Milk samples from each mother were collected 3 to 6 times a day through 3 to 7 days consecutively. Food samples as the duplicated method were collected from two mothers during the period of breast milk sample collection. Those were employed for POP (PCBs, DDTs, chlordanes, and HCB) analysis. PCB concentrations detected in breast milk samples showed a wide range of variation which was maximum 63 and 60% of relative standard deviation (RSD) in lipid and wet weight basis, respectively. The time course trend of those variations among the mothers did not show any typical pattern. A larger amount of PCB intake through food seemed to affect 10 h after those concentrations in breast milk in lipid weight basis. Intraclass correlation coefficient (ICC) analyses indicated that the appropriate sample size for good reproducibility of POP concentrations in breast milk required at least two samples for lipid and wet weight basis.

  11. Multi-element composition of historical lichen collections and bark samples, indicators of changing atmospheric conditions

    Science.gov (United States)

    Purvis, O. W.; Chimonides, P. D. J.; Jeffries, T. E.; Jones, G. C.; Rusu, A.-M.; Read, H.

    Thirty six element signatures were compared in historical Parmelia sulcata samples from the Natural History Museum herbarium collected over the period 1797-1967 with those recorded in the same species and tree bark sampled in 2000 from Burnham Beeches, lying 40 km west of London. Nineteen elements reached highest concentrations in herbarium samples, consistent with a pollution legacy and dust contamination in the herbarium. Healthy Parmelia sampled east and down-wind of London at a farm during peak SO 2 emissions in 1967 contained highest V, Ni, Zn, Cd, Se, Ge contents, supporting derivation from fuel combustion; the same sample was previously determined as having a low δ34S and high S and N contents. Lowest V, Co, Ni, Cu, Zn, Sn, Ba, Pb, Mo, Sb, Li, B, Cs, U, Th, Ga contents were recorded in a sample with a high δ34S and low S content collected in 1887 from a remote region from Ross-shire, Scotland. Se and Cd enrichment, never-the-less suggest a transboundary pollution influence. Lichen Pb concentrations from Burnham Beeches were amongst the lowest recorded in spite of lichens being collected close to roads. Herbarium samples help interpret changes in element deposition where few data exist, in spite of dust contamination.

  12. Optimal Policies for Random and Periodic Garbage Collections with Tenuring Threshold

    Science.gov (United States)

    Zhao, Xufeng; Nakamura, Syouji; Nakagawa, Toshio

    It is an important problem to determine the tenuring threshold to meet the pause time goal for a generational garbage collector. From such viewpoint, this paper proposes two stochastic models based on the working schemes of a generational garbage collector: One is random collection which occurs at a nonhomogeneous Poisson process and the other is periodic collection which occurs at periodic times. Since the cost suffered for minor collection increases, as the amount of surviving objects accumulates, tenuring minor collection should be made at some tenuring threshold. Using the techniques of cumulative processes and reliability theory, expected cost rates with tenuring threshold are obtained, and optimal policies which minimize them are discussed analytically and computed numerically.

  13. The concentration of Cs, Sr and other elements in water samples collected in a paddy field

    International Nuclear Information System (INIS)

    Ban-nai, Tadaaki; Hisamatsu, Shun'ichi; Yanai-Kudo, Masumi; Hasegawa, Hidenao; Torikai, Yuji

    2000-01-01

    To research elemental concentrations in soil water in a paddy field, samples of the soil water were collected with porous Teflon resin tubes which were buried in the field. The soil water collections were made at various depth, 2.5, 12.5, 25 and 35 cm from the surface in the paddy field, located in Rokkasho, Aomori, once every two weeks during the rice cultivation period, from May to October in 1998. The paddy field was irrigated from May 7th to July 20th, dried from July 20th to August 5th, then again irrigated until September 16th. Drastic changes of the alkaline earth metal elements, Fe and Mn in soil water samples were seen at the beginning and end of the midsummer drainage. The concentrations of Cs, Fe, Mn and NH 4 in soil water samples showed a similar variation pattern to that of alkaline earth metal elements in the waterlogged period. The change of redox potential was considered a possible cause for the concentration variation for these substances. (author)

  14. Gabor frames by sampling and periodization

    DEFF Research Database (Denmark)

    Søndergaard, Peter Lempel

    2007-01-01

    By sampling the window of Gabor frame for L-2 (R) belonging to Feichtingers algebra S-0 (R), one obtains a Gabor frame for l(2) (Z). In this article we present a survey of results by R. Orr and A.J.E.M. Janssen and extend their ideas to cover interrelations among Gabor frames for the four spaces L......-2 (R), l(2) (Z), L-2 ([O,L]) and C-L. Some new results about the general dual windows with respect to sampling and periodization are presented as well. This theory is used to show a new result of the Kaiblinger type to construct an approximation to the canonical dual window of a Gabor frame for L-2...

  15. Evaluation of the Use of Periodicals Collection of the Higher Education Council Documentation and Online Search Center: Arts and Humanities Periodicals

    OpenAIRE

    Elçin Özbudak

    1995-01-01

    Evaluation of the use perodicals collections in libraries is important as perodicals report the results of the latest scientific research and they are usually more expensive than other types of library materials. In this study we evaluate the use of Arts and Humanities periodicals in the collection of the Higher Education Council Documentation Center. Although the use of Arts and Humanities periodicals was found to be lower than, say, Biomedical periodicals collection, the number of journal t...

  16. Water sample-collection and distribution system

    Science.gov (United States)

    Brooks, R. R.

    1978-01-01

    Collection and distribution system samples water from six designated stations, filtered if desired, and delivers it to various analytical sensors. System may be controlled by Water Monitoring Data Acquisition System or operated manually.

  17. [Study on dynamic accumulation of index components from Bupleurum chinense in various collecting periods].

    Science.gov (United States)

    Wang, Qi-shuai; Li, Xiao-kun; Yang, Yun; Xiao, Gong-sheng; Feng, Wei-sheng

    2010-08-01

    To study the dynamic change law of volatile oil, saikosaponin a, d and alcohol-extract from Bupleurum chinense at Songxian region in Henan province, and to explore the optimal harvest period of Bupleurum chinense. With the contents of saikosaponin a and d, absorbance of volatile oil and percentage of alcohol-extract as indexes, HPLC-ELSD and ultraviolet spectrophotometry were successively used to analyze them. There are obvious differences among the contents of volatile oil, saikosaponin a, d and alcohol-extract in various collecting periods sample, the absorption of volatile oil in distillation was the highest in October, the content of saikosaponin a was the highest in September, the saikosaponin d in December and the percentage of alcohol-extract in October. The optimal harvest period of Bupleurum chinense at Songxian region in Henan is identified, which can provide scientific basis for crude drug production and processing.

  18. Characterization Of Core Sample Collected From The Saltstone Disposal Facility

    International Nuclear Information System (INIS)

    Cozzi, A.; Duncan, A.

    2010-01-01

    During the month of September 2008, grout core samples were collected from the Saltstone Disposal Facility, Vault 4, cell E. This grout was placed during processing campaigns in December 2007 from Deliquification, Dissolution and Adjustment Batch 2 salt solution. The 4QCY07 Waste Acceptance Criteria sample collected on 11/16/07 represents the salt solution in the core samples. Core samples were retrieved to initiate the historical database of properties of emplaced Saltstone and to demonstrate the correlation between field collected and laboratory prepared samples. Three samples were collected from three different locations. Samples were collected using a two-inch diameter concrete coring bit. In April 2009, the core samples were removed from the evacuated sample container, inspected, transferred to PVC containers, and backfilled with nitrogen. Samples furthest from the wall were the most intact cylindrically shaped cored samples. The shade of the core samples darkened as the depth of coring increased. Based on the visual inspection, sample 3-3 was selected for all subsequent analysis. The density and porosity of the Vault 4 core sample, 1.90 g/cm 3 and 59.90% respectively, were comparable to values achieved for laboratory prepared samples. X-ray diffraction analysis identified phases consistent with the expectations for hydrated Saltstone. Microscopic analysis revealed morphology features characteristic of cementitious materials with fly ash and calcium silicate hydrate gel. When taken together, the results of the density, porosity, x-ray diffraction analysis and microscopic analysis support the conclusion that the Vault 4, Cell E core sample is representative of the expected waste form.

  19. Assessing human error during collecting a hydrocarbon sample of ...

    African Journals Online (AJOL)

    This paper reports the assessment method of the hydrocarbon sample collection standard operation procedure (SOP) using THERP. The Performance Shaping Factors (PSF) from THERP analyzed and assessed the human errors during collecting a hydrocarbon sample of a petrochemical refinery plant. Twenty-two ...

  20. Scientific guidelines for preservation of samples collected from Mars

    International Nuclear Information System (INIS)

    Gooding, J.L.

    1990-04-01

    The maximum scientific value of Martian geologic and atmospheric samples is retained when the samples are preserved in the conditions that applied prior to their collection. Any sample degradation equates to loss of information. Based on detailed review of pertinent scientific literature, and advice from experts in planetary sample analysis, number values are recommended for key parameters in the environmental control of collected samples with respect to material contamination, temperature, head-space gas pressure, ionizing radiation, magnetic fields, and acceleration/shock. Parametric values recommended for the most sensitive geologic samples should also be adequate to preserve any biogenic compounds or exobiological relics

  1. Experimental and Sampling Design for the INL-2 Sample Collection Operational Test

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Amidan, Brett G.; Matzke, Brett D.

    2009-02-16

    This report describes the experimental and sampling design developed to assess sampling approaches and methods for detecting contamination in a building and clearing the building for use after decontamination. An Idaho National Laboratory (INL) building will be contaminated with BG (Bacillus globigii, renamed Bacillus atrophaeus), a simulant for Bacillus anthracis (BA). The contamination, sampling, decontamination, and re-sampling will occur per the experimental and sampling design. This INL-2 Sample Collection Operational Test is being planned by the Validated Sampling Plan Working Group (VSPWG). The primary objectives are: 1) Evaluate judgmental and probabilistic sampling for characterization as well as probabilistic and combined (judgment and probabilistic) sampling approaches for clearance, 2) Conduct these evaluations for gradient contamination (from low or moderate down to absent or undetectable) for different initial concentrations of the contaminant, 3) Explore judgment composite sampling approaches to reduce sample numbers, 4) Collect baseline data to serve as an indication of the actual levels of contamination in the tests. A combined judgmental and random (CJR) approach uses Bayesian methodology to combine judgmental and probabilistic samples to make clearance statements of the form "X% confidence that at least Y% of an area does not contain detectable contamination” (X%/Y% clearance statements). The INL-2 experimental design has five test events, which 1) vary the floor of the INL building on which the contaminant will be released, 2) provide for varying the amount of contaminant released to obtain desired concentration gradients, and 3) investigate overt as well as covert release of contaminants. Desirable contaminant gradients would have moderate to low concentrations of contaminant in rooms near the release point, with concentrations down to zero in other rooms. Such gradients would provide a range of contamination levels to challenge the sampling

  2. 222Rn in water: A comparison of two sample collection methods and two sample transport methods, and the determination of temporal variation in North Carolina ground water

    International Nuclear Information System (INIS)

    Hightower, J.H. III

    1994-01-01

    Objectives of this field experiment were: (1) determine whether there was a statistically significant difference between the radon concentrations of samples collected by EPA's standard method, using a syringe, and an alternative, slow-flow method; (2) determine whether there was a statistically significant difference between the measured radon concentrations of samples mailed vs samples not mailed; and (3) determine whether there was a temporal variation of water radon concentration over a 7-month period. The field experiment was conducted at 9 sites, 5 private wells, and 4 public wells, at various locations in North Carolina. Results showed that a syringe is not necessary for sample collection, there was generally no significant radon loss due to mailing samples, and there was statistically significant evidence of temporal variations in water radon concentrations

  3. Collection and preparation of samples for gamma spectrometry

    International Nuclear Information System (INIS)

    Pan Jingquan

    1994-01-01

    The paper presents the basic principles of sample collection and preparation: setting up unified sampling program, methods and procedures, sample packing, transportation and storage, determination of sample quantity, sample pretreatment and preparation of samples to be analysed, etc. for gamma spectrometry. And the paper also describes briefly the main methods and special issues of sampling and preparation for the same environmental and biological samples, such as, air, water, grass, soil and foods

  4. Improved sperm kinematics in semen samples collected after 2 h versus 4-7 days of ejaculation abstinence

    DEFF Research Database (Denmark)

    Alipour, H; Van Der Horst, G; Christiansen, O B

    2017-01-01

    STUDY QUESTION: Does a short abstinence period of only 2 h yield spermatozoa with better motility characteristics than samples collected after 4-7 days? SUMMARY ANSWER: Despite lower semen volume, sperm concentration, total sperm counts and total motile counts, higher percentages of motile...... a controlled repeated-measures design based on semen samples from 43 male partners, in couples attending for IVF treatment, who had a sperm concentration above 15 million/ml. Data were collected between June 2014 and December 2015 in the Fertility Unit of Aalborg University Hospital (Aalborg, Denmark......). PARTICIPANTS/MATERIALS, SETTING, METHODS: Participants provided a semen sample after 4-7 days of abstinence followed by another sample after only 2 h. For both ejaculates, sperm concentration, total sperm counts, motility groups and detailed kinematic parameters were assessed and compared by using the Sperm...

  5. Fieldwork and catalogue of samples collected in Polan, September 1995

    Energy Technology Data Exchange (ETDEWEB)

    Poulsen, N.; Drewniak, A.; Glowniak, E.; Ineson, J.; Matyja, B.A.; Merta, T.; Wierzbowski, A.

    1995-12-31

    This report lists the collection of samples taken during the field work of the EFP-95 Project, named `The Polish Middle to Late Jurassic Epicratonic basin, stratigraphy, facies and basin history` (short title: Jurrasic basin study, Poland) in Poland, August 7-20, 1995. The samples were collected for palynological studies, and/or sedimentaological studies, and/or source rock studies, and/or reservoir rock characteristics. Prepared samples (slides etc.) are stored in the collections of the GEUS, and remaining rock-material at the store of the GEUS. Field work with collection of samples for palynological studies has been carried earlier in 1988 and at the Oxfordian and Kimmeridgian Joint Working Groups Meeting 1992. (au)

  6. Self-Collected versus Clinician-Collected Sampling for Chlamydia and Gonorrhea Screening: A Systemic Review and Meta-Analysis

    Science.gov (United States)

    Lunny, Carole; Taylor, Darlene; Hoang, Linda; Wong, Tom; Gilbert, Mark; Lester, Richard; Krajden, Mel; Ogilvie, Gina

    2015-01-01

    Background The increases in STI rates since the late 1990s in Canada have occurred despite widespread primary care and targeted public health programs and in the setting of universal health care. More innovative interventions are required that would eliminate barriers to STI testing such as internet-based or mail-in home and community service testing for patients that are hard to reach, who refuse to go for clinician-based testing, or who decline an examination. Jurisdictions such as New Zealand and some American states currently use self-collected sampling, but without the required evidence to determine whether self-collected specimens are as accurate as clinician-collected specimens in terms of chlamydia and gonorrhea diagnostic accuracy. The objective of the review is to compare self-collected vaginal, urine, pharyngeal and rectal samples to our reference standard - clinician-collected cervical, urethral, pharyngeal and rectal sampling techniques to identify a positive specimen using nucleic acid amplification test assays. Methods The hierarchical summary receiver operating characteristic and the fixed effect models were used to assess the accuracy of comparable specimens that were collected by patients compared to clinicians. Sensitivity and specificity estimates with 95% confidence intervals (CI) were reported as our main outcome measures. Findings We included 21 studies based on over 6100 paired samples. Fourteen included studies examined chlamydia only, 6 compared both gonorrhea and chlamydia separately in the same study, and one examined gonorrhea. The six chlamydia studies comparing self-collection by vaginal swab to a clinician-collected cervical swab had the highest sensitivity (92%, 95% CI 87-95) and specificity (98%, 95% CI 97-99), compared to other specimen-types (urine/urethra or urine/cervix). Six studies compared urine self-samples to urethra clinician-collected samples in males and produced a sensitivity of 88% (95% CI 83-93) and a specificity of

  7. Acceptability of self-collected versus provider-collected sampling for HPV DNA testing among women in rural El Salvador.

    Science.gov (United States)

    Rosenbaum, Alan J; Gage, Julia C; Alfaro, Karla M; Ditzian, Lauren R; Maza, Mauricio; Scarinci, Isabel C; Felix, Juan C; Castle, Philip E; Villalta, Sofia; Miranda, Esmeralda; Cremer, Miriam L

    2014-08-01

    To determine the acceptability of self-collected versus provider-collected sampling among women participating in public sector HPV-based cervical cancer screening in El Salvador. Two thousand women aged 30-49 years underwent self-collected and provider-collected sampling with careHPV between October 2012 and March 2013 (Qiagen, Gaithersburg, MD, USA). After sample collection, a random sample of women (n=518) were asked about their experience. Participants were questioned regarding sampling method preference, previous cervical cancer screening, HPV and cervical cancer knowledge, HPV risk factors, and demographic information. All 518 women approached to participate in this questionnaire study agreed and were enrolled, 27.8% (142 of 511 responding) of whom had not received cervical cancer screening within the past 3 years and were considered under-screened. Overall, 38.8% (n=201) preferred self-collection and 31.9% (n=165) preferred provider collection. Self-collection preference was associated with prior tubal ligation, HPV knowledge, future self-sampling preference, and future home-screening preference (P<0.05). Reasons for self-collection preference included privacy/embarrassment, ease, and less pain; reasons cited for provider-collection preference were result accuracy and provider knowledge/experience. Self-sampling was found to be acceptable, therefore screening programs could consider offering this option either in the clinic or at home. Self-sampling at home may increase coverage in low-resource countries and reduce the burden that screening places upon clinical infrastructure. Copyright © 2014 International Federation of Gynecology and Obstetrics. All rights reserved.

  8. Evaluation of standard methods for collecting and processing fuel moisture samples

    Science.gov (United States)

    Sally M. Haase; José Sánchez; David R. Weise

    2016-01-01

    A variety of techniques for collecting and processing samples to determine moisture content of wildland fuels in support of fire management activities were evaluated. The effects of using a chainsaw or handsaw to collect samples of largediameter wood, containers for storing and transporting collected samples, and quick-response ovens for estimating moisture content...

  9. Curating NASA's Past, Present, and Future Astromaterial Sample Collections

    Science.gov (United States)

    Zeigler, R. A.; Allton, J. H.; Evans, C. A.; Fries, M. D.; McCubbin, F. M.; Nakamura-Messenger, K.; Righter, K.; Zolensky, M.; Stansbery, E. K.

    2016-01-01

    The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC curation) is responsible for curating all of NASA's extraterrestrial samples. JSC presently curates 9 different astromaterials collections in seven different clean-room suites: (1) Apollo Samples (ISO (International Standards Organization) class 6 + 7); (2) Antarctic Meteorites (ISO 6 + 7); (3) Cosmic Dust Particles (ISO 5); (4) Microparticle Impact Collection (ISO 7; formerly called Space-Exposed Hardware); (5) Genesis Solar Wind Atoms (ISO 4); (6) Stardust Comet Particles (ISO 5); (7) Stardust Interstellar Particles (ISO 5); (8) Hayabusa Asteroid Particles (ISO 5); (9) OSIRIS-REx Spacecraft Coupons and Witness Plates (ISO 7). Additional cleanrooms are currently being planned to house samples from two new collections, Hayabusa 2 (2021) and OSIRIS-REx (2023). In addition to the labs that house the samples, we maintain a wide variety of infra-structure facilities required to support the clean rooms: HEPA-filtered air-handling systems, ultrapure dry gaseous nitrogen systems, an ultrapure water system, and cleaning facilities to provide clean tools and equipment for the labs. We also have sample preparation facilities for making thin sections, microtome sections, and even focused ion-beam sections. We routinely monitor the cleanliness of our clean rooms and infrastructure systems, including measurements of inorganic or organic contamination, weekly airborne particle counts, compositional and isotopic monitoring of liquid N2 deliveries, and daily UPW system monitoring. In addition to the physical maintenance of the samples, we track within our databases the current and ever changing characteristics (weight, location, etc.) of more than 250,000 individually numbered samples across our various collections, as well as more than 100,000 images, and countless "analog" records that record the sample processing records of each individual sample. JSC Curation is co-located with JSC

  10. Organic analysis of ambient samples collected near Tank 241-C-103: Results from samples collected on May 12, 1994

    International Nuclear Information System (INIS)

    Clauss, T.W.; Ligotke, M.W.; McVeety, B.D.; Lucke, R.B.; Young, J.S.; McCulloch, M.; Fruchter, J.S.; Goheen, S.C.

    1995-06-01

    This report describes organic analyses results from ambient samples collected both upwind and through the vapor sampling system (VSS) near Hanford waste storage Tank 241-C-103 (referred to as Tank C-103). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed. Quantitative results were obtained for organic compounds. Five organic tentatively identified compounds (TICS) were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and the reported concentrations are semiquantitative estimates. In addition, we looked for the 40 standard TO-14 analytes. We observed 39. Of these, only one was observed above the 2-ppbv calibrated instrument detection limit. Dichloromethane was above the detection limits using both methods, but the result from the TO-14 method is traceable to a standard gas mixture and is considered more accurate. Organic analytes were found only in the sample collected through the VSS, suggesting that these compounds were residual contamination from a previous sampling job. Detailed descriptions of the results appear in the text

  11. Methods for the collection of subsurface samples during environmental site assessments

    International Nuclear Information System (INIS)

    Weinstock, E.A.

    1996-01-01

    This paper discusses numerous sample collection techniques that have been successfully employed during Phase 2 Assessments and presents case histories of their application. Pollutants of concern include PCE and petroleum. The collection of shallow soil samples is described using commercially available hand augers and hand-driven core samplers. These devices are modified with extensions to collect deeper samples from storm drains and leaching pools. The performance of soil gas surveys are described using both hand-driven sample probes and vehicle-mounted, hydraulically driven vapor probes. Once the soil vapor is collected at the ground surface, a sample of the media is either analyzed on-site using a field-operated detection device or delivered to a laboratory for analysis. Application and case histories of the Geoprobe(trademark)sampling system, a form of direct push technology, are described. This device uses vehicle-mounted, hydraulically-driven sample probes. The probe can be advanced to depths as great as 100 feet below grade and can retrieve soil, soil gas and groundwater samples

  12. Importance of sampling frequency when collecting diatoms

    KAUST Repository

    Wu, Naicheng; Faber, Claas; Sun, Xiuming; Qu, Yueming; Wang, Chao; Ivetic, Snjezana; Riis, Tenna; Ulrich, Uta; Fohrer, Nicola

    2016-01-01

    There has been increasing interest in diatom-based bio-assessment but we still lack a comprehensive understanding of how to capture diatoms’ temporal dynamics with an appropriate sampling frequency (ASF). To cover this research gap, we collected

  13. Protocol for collecting eDNA samples from streams [Version 2.3

    Science.gov (United States)

    K. J. Carim; T. Wilcox; M. K. Young; K. S. McKelvey; M. K. Schwartz

    2015-01-01

    Throughout the 2014 field season, we had over two dozen biologist throughout the western US collect over 300 samples for eDNA analysis with paired controls. Control samples were collected by filtering 0.5 L of distilled water. No samples had any evidence of field contamination. This method of sampling verifies the cleanliness of the field equipment, as well as the...

  14. Sample collection and sample analysis plan in support of the 105-C/190-C concrete and soil sampling activities

    International Nuclear Information System (INIS)

    Marske, S.G.

    1996-07-01

    This sampling and analysis plan describes the sample collection and sample analysis in support of the 105-C water tunnels and 190-C main pumphouse concrete and soil sampling activities. These analytical data will be used to identify the radiological contamination and presence of hazardous materials to support the decontamination and disposal activities

  15. Quality standards for sample collection in coagulation testing.

    Science.gov (United States)

    Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Lima-Oliveira, Gabriel; Guidi, Gian Cesare; Favaloro, Emmanuel J

    2012-09-01

    Preanalytical activities, especially those directly connected with blood sample collection and handling, are the most vulnerable steps throughout the testing process. The receipt of unsuitable samples is commonplace in laboratory practice and represents a serious problem, given the reliability of test results can be adversely compromised following analysis of these specimens. The basic criteria for an appropriate and safe venipuncture are nearly identical to those used for collecting blood for clinical chemistry and immunochemistry testing, and entail proper patient identification, use of the correct technique, as well as appropriate devices and needles. There are, however, some peculiar aspects, which are deemed to be particularly critical when collecting quality specimens for clot-based tests, and these require clearer recognition. These include prevention of prolonged venous stasis, collection of nonhemolyzed specimens, order of draw, and appropriate filling and mixing of the primary collection tubes. All of these important preanalytical issues are discussed in this article, and evidence-based suggestions as well as recommendations on how to obtain a high-quality sample for coagulation testing are also illustrated. We have also performed an investigation aimed to identify variation of test results due to underfilling of primary blood tubes, and have identified a clinically significant bias in test results when tubes are drawn at less than 89% of total fill for activated partial thromboplastin time, less than 78% for fibrinogen, and less than 67% for coagulation factor VIII, whereas prothrombin time and activated protein C resistance remain relatively reliable even in tubes drawn at 67% of the nominal volume. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. Collecting Comet Samples by ER-2 Aircraft: Cosmic Dust Collection During the Draconid Meteor Shower in October 2012

    Science.gov (United States)

    Bastien, Ron; Burkett, P. J.; Rodriquez, M.; Frank, D.; Gonzalez, C.; Robinson, G.-A.; Zolensky, M.; Brown, P.; Campbell-Brown, M.; Broce, S.; hide

    2014-01-01

    Many tons of dust grains, including samples of asteroids and comets, fall from space into the Earth's atmosphere each day. NASA periodically collects some of these particles from the Earth's stratosphere using sticky collectors mounted on NASA's high-flying aircraft. Sometimes, especially when the Earth experiences a known meteor shower, a special opportunity is presented to associate cosmic dust particles with a known source. NASA JSC's Cosmic Dust Collection Program has made special attempts to collect dust from particular meteor showers and asteroid families when flights can be planned well in advance. However, it has rarely been possible to make collections on very short notice. In 2012, the Draconid meteor shower presented that opportunity. The Draconid meteor shower, originating from Comet 21P/Giacobini-Zinner, has produced both outbursts and storms several times during the last century, but the 2012 event was not predicted to be much of a show. Because of these predictions, the Cosmic Dust team had not targeted a stratospheric collection effort for the Draconids, despite the fact that they have one of the slowest atmospheric entry velocities (23 km/s) of any comet shower, and thus offer significant possibilities of successful dust capture. However, radar measurements obtained by the Canadian Meteor Orbit Radar during the 2012 Draconids shower indicated a meteor storm did occur October 8 with a peak at 16:38 (+/-5 min) UTC for a total duration of approximately 2 hours.

  17. Standardized Method for Measuring Collection Efficiency from Wipe-sampling of Trace Explosives.

    Science.gov (United States)

    Verkouteren, Jennifer R; Lawrence, Jeffrey A; Staymates, Matthew E; Sisco, Edward

    2017-04-10

    One of the limiting steps to detecting traces of explosives at screening venues is effective collection of the sample. Wipe-sampling is the most common procedure for collecting traces of explosives, and standardized measurements of collection efficiency are needed to evaluate and optimize sampling protocols. The approach described here is designed to provide this measurement infrastructure, and controls most of the factors known to be relevant to wipe-sampling. Three critical factors (the applied force, travel distance, and travel speed) are controlled using an automated device. Test surfaces are chosen based on similarity to the screening environment, and the wipes can be made from any material considered for use in wipe-sampling. Particle samples of the explosive 1,3,5-trinitroperhydro-1,3,5-triazine (RDX) are applied in a fixed location on the surface using a dry-transfer technique. The particle samples, recently developed to simulate residues made after handling explosives, are produced by inkjet printing of RDX solutions onto polytetrafluoroethylene (PTFE) substrates. Collection efficiency is measured by extracting collected explosive from the wipe, and then related to critical sampling factors and the selection of wipe material and test surface. These measurements are meant to guide the development of sampling protocols at screening venues, where speed and throughput are primary considerations.

  18. Profiling a Periodicals Collection

    Science.gov (United States)

    Bolgiano, Christina E.; King, Mary Kathryn

    1978-01-01

    Libraries need solid information upon which to base collection development decisions. Specific evaluative methods for determining scope, access, and usefullness are described. Approaches used for data collection include analysis of interlibrary loan requests, comparison with major bibliographies, and analysis of accessibility through available…

  19. Self-collected versus clinician-collected sampling for sexually transmitted infections: a systematic review and meta-analysis protocol.

    Science.gov (United States)

    Taylor, Darlene; Lunny, Carole; Wong, Tom; Gilbert, Mark; Li, Neville; Lester, Richard; Krajden, Mel; Hoang, Linda; Ogilvie, Gina

    2013-10-10

    Three meta-analyses and one systematic review have been conducted on the question of whether self-collected specimens are as accurate as clinician-collected specimens for STI screening. However, these reviews predate 2007 and did not analyze rectal or pharyngeal collection sites. Currently, there is no consensus on which sampling method is the most effective for the diagnosis of genital chlamydia (CT), gonorrhea (GC) or human papillomavirus (HPV) infection. Our meta-analysis aims to be comprehensive in that it will examine the evidence of whether self-collected vaginal, urine, pharyngeal and rectal specimens provide as accurate a clinical diagnosis as clinician-collected samples (reference standard). Eligible studies include both randomized and non-randomized controlled trials, pre- and post-test designs, and controlled observational studies. The databases that will be searched include the Cochrane Database of Systematic Reviews, Web of Science, Database of Abstracts of Reviews of Effects (DARE), EMBASE and PubMed/Medline. Data will be abstracted independently by two reviewers using a standardized pre-tested data abstraction form. Heterogeneity will be assessed using the Q2 test. Sensitivity and specificity estimates with 95% confidence intervals as well as negative and positive likelihood ratios will be pooled and weighted using random effects meta-analysis, if appropriate. A hierarchical summary receiver operating characteristics curve for self-collected specimens will be generated. This synthesis involves a meta-analysis of self-collected samples (urine, vaginal, pharyngeal and rectal swabs) versus clinician-collected samples for the diagnosis of CT, GC and HPV, the most prevalent STIs. Our systematic review will allow patients, clinicians and researchers to determine the diagnostic accuracy of specimens collected by patients compared to those collected by clinicians in the detection of chlamydia, gonorrhea and HPV.

  20. Soil sample collection and analysis for the Fugitive Dust Characterization Study

    Science.gov (United States)

    Ashbaugh, Lowell L.; Carvacho, Omar F.; Brown, Michael S.; Chow, Judith C.; Watson, John G.; Magliano, Karen C.

    A unique set of soil samples was collected as part of the Fugitive Dust Characterization Study. The study was carried out to establish whether or not source profiles could be constructed using novel analytical methods that could distinguish soil dust sources from each other. The soil sources sampled included fields planted in cotton, almond, tomato, grape, and safflower, dairy and feedlot facilities, paved and unpaved roads (both urban and rural), an agricultural staging area, disturbed land with salt buildup, and construction areas where the topsoil had been removed. The samples were collected using a systematic procedure designed to reduce sampling bias, and were stored frozen to preserve possible organic signatures. For this paper the samples were characterized by particle size (percent sand, silt, and clay), dry silt content (used in EPA-recommended fugitive dust emission factors), carbon and nitrogen content, and potential to emit both PM 10 and PM 2.5. These are not the "novel analytical methods" referred to above; rather, it was the basic characterization of the samples to use in comparing analytical methods by other scientists contracted to the California Air Resources Board. The purpose of this paper is to document the methods used to collect the samples, the collection locations, the analysis of soil type and potential to emit PM 10, and the sample variability, both within field and between fields of the same crop type.

  1. Collection of biological samples in forensic toxicology.

    Science.gov (United States)

    Dinis-Oliveira, R J; Carvalho, F; Duarte, J A; Remião, F; Marques, A; Santos, A; Magalhães, T

    2010-09-01

    Forensic toxicology is the study and practice of the application of toxicology to the purposes of the law. The relevance of any finding is determined, in the first instance, by the nature and integrity of the specimen(s) submitted for analysis. This means that there are several specific challenges to select and collect specimens for ante-mortem and post-mortem toxicology investigation. Post-mortem specimens may be numerous and can endow some special difficulties compared to clinical specimens, namely those resulting from autolytic and putrefactive changes. Storage stability is also an important issue to be considered during the pre-analytic phase, since its consideration should facilitate the assessment of sample quality and the analytical result obtained from that sample. The knowledge on degradation mechanisms and methods to increase storage stability may enable the forensic toxicologist to circumvent possible difficulties. Therefore, advantages and limitations of specimen preservation procedures are thoroughfully discussed in this review. Presently, harmonized protocols for sampling in suspected intoxications would have obvious utility. In the present article an overview is given on sampling procedures for routinely collected specimens as well as on alternative specimens that may provide additional information on the route and timing of exposure to a specific xenobiotic. Last, but not least, a discussion on possible bias that can influence the interpretation of toxicological results is provided. This comprehensive review article is intented as a significant help for forensic toxicologists to accomplish their frequently overwhelming mission.

  2. Collection and control of tritium bioassay samples at Pantex

    International Nuclear Information System (INIS)

    Fairrow, N.L.; Ivie, W.E.

    1992-01-01

    Pantex is the final assembly/disassembly point for US nuclear weapons. The Pantex internal dosimetry section monitors radiation workers once a month for tritium exposure. In order to manage collection and control of the bioassay specimens efficiently, a bar code system for collection of samples was developed and implemented to speed up the process and decrease the number of errors probable when transferring data. In the past, all the bioassay data from samples were entered manually into a computer database. Transferring the bioassay data from the liquid scintillation counter to each individual's dosimetry record required as much as two weeks of concentrated effort

  3. Revisiting random walk based sampling in networks: evasion of burn-in period and frequent regenerations.

    Science.gov (United States)

    Avrachenkov, Konstantin; Borkar, Vivek S; Kadavankandy, Arun; Sreedharan, Jithin K

    2018-01-01

    In the framework of network sampling, random walk (RW) based estimation techniques provide many pragmatic solutions while uncovering the unknown network as little as possible. Despite several theoretical advances in this area, RW based sampling techniques usually make a strong assumption that the samples are in stationary regime, and hence are impelled to leave out the samples collected during the burn-in period. This work proposes two sampling schemes without burn-in time constraint to estimate the average of an arbitrary function defined on the network nodes, for example, the average age of users in a social network. The central idea of the algorithms lies in exploiting regeneration of RWs at revisits to an aggregated super-node or to a set of nodes, and in strategies to enhance the frequency of such regenerations either by contracting the graph or by making the hitting set larger. Our first algorithm, which is based on reinforcement learning (RL), uses stochastic approximation to derive an estimator. This method can be seen as intermediate between purely stochastic Markov chain Monte Carlo iterations and deterministic relative value iterations. The second algorithm, which we call the Ratio with Tours (RT)-estimator, is a modified form of respondent-driven sampling (RDS) that accommodates the idea of regeneration. We study the methods via simulations on real networks. We observe that the trajectories of RL-estimator are much more stable than those of standard random walk based estimation procedures, and its error performance is comparable to that of respondent-driven sampling (RDS) which has a smaller asymptotic variance than many other estimators. Simulation studies also show that the mean squared error of RT-estimator decays much faster than that of RDS with time. The newly developed RW based estimators (RL- and RT-estimators) allow to avoid burn-in period, provide better control of stability along the sample path, and overall reduce the estimation time. Our

  4. Studies on radioimmunoassay diagnosis of cow pregnancy at an early period by milk sample communication

    International Nuclear Information System (INIS)

    Wu Meiwen

    1986-01-01

    Cow pregancy was diagnosed at an early period by milk sample communication and radioimmunoassay (RIA). Liquid milk samples were converted into solid forms on filter paper and mailed to the laboratory from appointed locations, and concentrations of progesterone in milk samples were then determined by RIA method. Milks were sampled 19 and 23 days after mating. Criterion used for the judgement of cow pregnancy was as follows: When the progesterone content in milk was 5 ng/ml or less, the cow was not pregnant; when progesterone content was between 5-11 ng/ml, it was doubtful; when progesterone content was 11 ng/ml or more, it was pregnant. According to this criterion, among 215 cows, 131 were pregnant, 73 were not pregnant, and 11 were doubtful. The results were further checked by palpation 3 months after inseminations. The unpregnancy and pregnancy accuracies were 97.6% and 89.2%, respectively. Forther milk samples were collected on 44 days for above cows that had been diagnosed on 19 and 23 days showing pregnancy to diagnose embryo forming. Among 91 cows, 74 had embryo. 7 had none, and the other 10 were doubtful. The embryo and unembryo accuracies were 94.6% and 100% respectively checking by palpation 3 months after inseminations

  5. Fast egg collection method greatly improves randomness of egg sampling in Drosophila melanogaster

    DEFF Research Database (Denmark)

    Schou, Mads Fristrup

    2013-01-01

    When obtaining samples for population genetic studies, it is essential that the sampling is random. For Drosophila, one of the crucial steps in sampling experimental flies is the collection of eggs. Here an egg collection method is presented, which randomizes the eggs in a water column...... and diminishes environmental variance. This method was compared with a traditional egg collection method where eggs are collected directly from the medium. Within each method the observed and expected standard deviations of egg-to-adult viability were compared, whereby the difference in the randomness...... and to obtain a representative collection of genotypes, the method presented here is strongly recommended when collecting eggs from Drosophila....

  6. A 'feather-trap' for collecting DNA samples from birds.

    Science.gov (United States)

    Maurer, Golo; Beck, Nadeena; Double, Michael C

    2010-01-01

    Genetic analyses of birds are usually based on DNA extracted from a blood sample. For some species, however, obtaining blood samples is difficult because they are sensitive to handling, pose a conservation or animal welfare concern, or evade capture. In such cases, feathers obtained from live birds in the wild can provide an alternative source of DNA. Here, we provide the first description and evaluation of a 'feather-trap', consisting of small strips of double-sided adhesive tape placed close to a nest with chicks, as a simple, inexpensive and minimally invasive method to collect feathers. The feather-trap was tested in tropical conditions on the Australian pheasant coucal (Centropus phasianinus). None of the 12 pairs of coucals on which the feather-trap was used abandoned the nest, and feeding rates did not differ from those of birds not exposed to a feather-trap. On average, 4.2 feathers were collected per trap over 2-5 days and, despite exposure to monsoonal rain, DNA was extracted from 71.4% of samples, albeit at low concentrations. The amount of genomic DNA extracted from each feather was sufficient to reliably genotype individuals at up to five microsatellite loci for parentage analysis. We show that a feather-trap can provide a reliable alternative for obtaining DNA in species where taking blood is difficult. It may also prove useful for collecting feather samples for other purposes, e.g. stable-isotope analysis. © 2009 Blackwell Publishing Ltd.

  7. Composition of Trace Metals in Dust Samples Collected from Selected High Schools in Pretoria, South Africa

    Directory of Open Access Journals (Sweden)

    J. O. Olowoyo

    2016-01-01

    Full Text Available Potential health risks associated with trace metal pollution have necessitated the importance of monitoring their levels in the environment. The present study investigated the concentrations and compositions of trace metals in dust samples collected from classrooms and playing ground from the selected high schools In Pretoria. Schools were selected from Pretoria based on factors such as proximity to high traffic ways, industrial areas, and residential areas. Thirty-two dust samples were collected from inside and outside the classrooms, where learners often stay during recess period. The dust samples were analysed for trace metal concentrations using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS. The composition of the elements showed that the concentrations of Zn were more than all other elements except from one of the schools. There were significant differences in the concentrations of trace metals from the schools (p<0.05. Regular cleaning, proximity to busy road, and well maintained gardens seem to have positive effects on the concentrations of trace metals recorded from the classrooms dust. The result further revealed a positive correlation for elements such as Pb, Cu, Zn, Mn, and Sb, indicating that the dust might have a common source.

  8. Radioactivity measurements of soil samples in the Region Vranje (Bratoselce Village) for the period 2001-2004

    International Nuclear Information System (INIS)

    Eremic-savkovic, M.; Pantelic, G.; Tanaskovic, I.; Vuletic, V.; Javorina, L.

    2006-01-01

    Systematic examination of radioactive contamination of soil samples was established at the Institute for Occupational and Radiological Health. With the bombing of our country (Spring 1999) the monitoring of radioactivity has changed. We also measured the activities of uranium and it descendants. This paper presents the results of radioactivity monitoring of the soil in small area 700 m near village Bratoselce in region Vranje during the period 2001 - 2004. From 2001 to 2004, we collected different samples from this fenced area as well as outside this area assuming not to be contaminated, before, during and after decontamination. Some soil samples were made as a mix of small samples from a large area of location. Other samples were taken at the points formerly designated as contaminated or from shell-craters seen on the fenced area surface. All samples were analyzed by gamma spectrometry and measurements of alpha and beta activity. On the basis of measurements of soil activities, analysis of 238 U and 235 U, as well as in comparison with natural activity ratio being 21.4, it may be concluded that depleted uranium contamination was present both in the fenced area and outside it, because this ratio in the samples of soil was found to be 34 to 73. Natural activity in soil samples was slightly higher in relation to mean soil activity in Serbia. (authors)

  9. Ground-water sample collection and analysis plan for the ground-water surveillance project

    International Nuclear Information System (INIS)

    Bryce, R.W.; Evans, J.C.; Olsen, K.B.

    1991-12-01

    The Pacific Northwest Laboratory performs ground-water sampling activities at the US Department of Energy's (DOE's) Hanford Site in support of DOE's environmental surveillance responsibilities. The purpose of this document is to translate DOE's General Environmental Protection Program (DOE Order 5400.1) into a comprehensive ground-water sample collection and analysis plan for the Hanford Site. This sample collection and analysis plan sets forth the environmental surveillance objectives applicable to ground water, identifies the strategy for selecting sample collection locations, and lists the analyses to be performed to meet those objectives

  10. Evaluation of a novel dried blood spot collection device (HemaSpot™) to test blood samples collected from dogs for antibodies to Leishmania infantum.

    Science.gov (United States)

    Rosypal, Alexa C; Pick, Leanne D; Hernandez, Jaime O Esquivel; Lindsay, David S

    2014-09-15

    Collection of blood samples from veterinary and wildlife patients is often challenging because the samples have to be collected on farm or in the wild under various environmental conditions. This poses many technical problems associated with venipuncture materials, their safe use and disposal, transportation and processing of collected samples. Dried blood spot (DBS) sample collection techniques offer a simple and practical alternative to traditional blood collection methods to obtain blood samples from animals for parasite antibody evaluation. The DBS collection devices are compact, simple to use, and are particularly useful for large number of samples. Additionally, DBS samples take up less space and they are easier to transport than traditional venipuncture-collected blood samples. Visceral leishmaniasis (VL) is a potentially fatal parasitic disease of dogs and humans and it is frequently diagnosed by antibody tests. Immunochromatographic tests (ICT) for antibodies to Leishmania infantum are commercially available for dogs and they produce qualitative results in minutes. Measurement of canine antibodies to L. infantum with the ICT using traditional venipuncture has been validated previously, but the use of DBS samples has not been evaluated using this method. The purpose of the present study was to determine the ability of DBS samples to detect antibodies to L. infantum in dogs using a commercial ICT assay. One hundred plasma samples from dogs experimentally infected with the LIVT-1 strain of L. infantum were collected by venipuncture and frozen. Individual samples were thawed, and then 80 μl plasma (2 drops) was aliquotted onto the 8-spoked disk pad on individual DBS sample collection devices (HemaSpot™, Spot-On Sciences, Austin, TX), dried, and stored in the dark at room temperature. After one month and six months, respectively, 2 spokes of the 8 spokes of the disk pad of each DBS sample were removed and eluted in 200 μl PBS. The eluate was used to test

  11. Concentration and characteristics of depleted uranium in biological and water samples collected in Bosnia and Herzegovina

    International Nuclear Information System (INIS)

    Jia Guogang; Belli, Maria; Sansone, Umberto; Rosamilia, Silvia; Gaudino, Stefania

    2006-01-01

    During Balkan conflicts in 1994-1995, depleted uranium (DU) ordnance was employed and was left in the battlefield. Health concern is related to the risk arising from contamination of the environment with DU penetrators and dust. In order to evaluate the impact of DU on the environment and population in Bosnia and Herzegovina, radiological survey of DU in biological and water samples were carried out over the period 12-24 October 2002. The uranium isotopic concentrations in biological samples collected in Bosnia and Herzegovina, mainly lichens, mosses and barks, were found to be in the range of 0.27-35.7 Bq kg -1 for 238 U, 0.24-16.8 Bq kg -1 for 234 U, and 0.02-1.11 Bq kg -1 for 235 U, showing uranium levels to be higher than in the samples collected at the control site. Moreover, the 236 U in some of the samples was detectable. The isotopic ratios of 234 U/ 238 U showed DU to be detectable in many biological samples at most sites examined, but in very low levels. The presence of DU in the biological samples was as a result of DU contamination in air. The uranium concentrations in water samples collected in Bosnia and Herzegovina were found to be in the range of 0.27-16.2 mBq l -1 for 238 U, 0.41-15.6 mBq l -1 for 234 U and 0.012-0.695 mBq l -1 for 235 U, and two water samples were observed to be DU positive; these values are much lower than those in mineral water found in central Italy and below the WHO guideline for public drinking water. From radiotoxicological point of view, at this moment there is no significant radiological risk related to these investigated sites in terms of possible DU contamination of water and/or plants

  12. On the improvement of blood sample collection at clinical laboratories.

    Science.gov (United States)

    Grasas, Alex; Ramalhinho, Helena; Pessoa, Luciana S; Resende, Mauricio G C; Caballé, Imma; Barba, Nuria

    2014-01-09

    Blood samples are usually collected daily from different collection points, such hospitals and health centers, and transported to a core laboratory for testing. This paper presents a project to improve the collection routes of two of the largest clinical laboratories in Spain. These routes must be designed in a cost-efficient manner while satisfying two important constraints: (i) two-hour time windows between collection and delivery, and (ii) vehicle capacity. A heuristic method based on a genetic algorithm has been designed to solve the problem of blood sample collection. The user enters the following information for each collection point: postal address, average collecting time, and average demand (in thermal containers). After implementing the algorithm using C programming, this is run and, in few seconds, it obtains optimal (or near-optimal) collection routes that specify the collection sequence for each vehicle. Different scenarios using various types of vehicles have been considered. Unless new collection points are added or problem parameters are changed substantially, routes need to be designed only once. The two laboratories in this study previously planned routes manually for 43 and 74 collection points, respectively. These routes were covered by an external carrier company. With the implementation of this algorithm, the number of routes could be reduced from ten to seven in one laboratory and from twelve to nine in the other, which represents significant annual savings in transportation costs. The algorithm presented can be easily implemented in other laboratories that face this type of problem, and it is particularly interesting and useful as the number of collection points increases. The method designs blood collection routes with reduced costs that meet the time and capacity constraints of the problem.

  13. Active Collection of Land Cover Sample Data from Geo-Tagged Web Texts

    Directory of Open Access Journals (Sweden)

    Dongyang Hou

    2015-05-01

    Full Text Available Sample data plays an important role in land cover (LC map validation. Traditionally, they are collected through field survey or image interpretation, either of which is costly, labor-intensive and time-consuming. In recent years, massive geo-tagged texts are emerging on the web and they contain valuable information for LC map validation. However, this kind of special textual data has seldom been analyzed and used for supporting LC map validation. This paper examines the potential of geo-tagged web texts as a new cost-free sample data source to assist LC map validation and proposes an active data collection approach. The proposed approach uses a customized deep web crawler to search for geo-tagged web texts based on land cover-related keywords and string-based rules matching. A data transformation based on buffer analysis is then performed to convert the collected web texts into LC sample data. Using three provinces and three municipalities directly under the Central Government in China as study areas, geo-tagged web texts were collected to validate artificial surface class of China’s 30-meter global land cover datasets (GlobeLand30-2010. A total of 6283 geo-tagged web texts were collected at a speed of 0.58 texts per second. The collected texts about built-up areas were transformed into sample data. User’s accuracy of 82.2% was achieved, which is close to that derived from formal expert validation. The preliminary results show that geo-tagged web texts are valuable ancillary data for LC map validation and the proposed approach can improve the efficiency of sample data collection.

  14. Collection and preparation of wet and dry stream-sediment samples

    International Nuclear Information System (INIS)

    Puchlik, K.

    1977-03-01

    Lawrence Livermore Laboratory is responsible for the Hydrogeochemistry and Stream Sediment Reconnaissance (HSSR) program for uranium in the seven far western states. The work thus far has concentrated on the arid to semi-arid regions of the West and this paper discusses the collection and preparation of sediment samples in the Basin and Range province. The sample collection and preparation procedures described here may not be applicable to other parts of the far western states or other areas. These procedures also differ somewhat from those used by the other three laboratories involved in the HSSR program

  15. Seasonal associations and atmospheric transport distances of Fusarium collected with unmanned aerial vehicles and ground-based sampling devices

    Science.gov (United States)

    Schmale, David; Ross, Shane; Lin, Binbin

    2014-05-01

    Spores of fungi in the genus Fusarium may be transported through the atmosphere over long distances. Members of this genus are important pathogens and mycotoxin producers. New information is needed to characterize seasonal trends in atmospheric loads of Fusarium and to pinpoint the source(s) of inoculum at both local (farm) and regional (state or country) scales. Spores of Fusarium were collected from the atmosphere in an agricultural ecosystem in Blacksburg, VA, USA using a Burkard volumetric sampler (BVS) 1 m above ground level and autonomous unmanned aerial vehicles (UAVs) 100 m above ground level. More than 2,200 colony forming units (CFUs) of Fusarium were collected during 104 BVS sampling periods and 180 UAV sampling periods over four calendar years (2009-2012). Spore concentrations ranged from 0 to 13 and 0 to 23 spores m-3 for the BVS and the UAVs, respectively. Spore concentrations were generally higher in the fall, spring, and summer, and lower in the winter. Spore concentrations from the BVS were generally higher than those from the UAVs for both seasonal and hourly collections. Some of the species of Fusarium identified from our collections have not been previously reported in the state of Virginia. A Gaussian plume transport model was used to estimate distances to the potential inoculum source(s) by season. This work extends previous studies showing an association between atmospheric transport barriers (Lagrangian coherent structures or LCSs) and the movement of Fusarium in the lower atmosphere. An increased understanding of the aerobiology of Fusarium may contribute to new and improved control strategies for diseases causes by fusaria in the future.

  16. Pediatric blood sample collection from a pre-existing peripheral intravenous (PIV) catheter.

    Science.gov (United States)

    Braniff, Heather; DeCarlo, Ann; Haskamp, Amy Corey; Broome, Marion E

    2014-01-01

    Aiming to minimize pain in a hospitalized child, the purpose of this observational study was to describe characteristics of blood samples collected from pre-existing peripheral intravenous (PIV) catheters in pediatric patients. One hundred and fifty blood samples were reviewed for number of unusable samples requiring a specimen to be re-drawn. Success of the blood draw and prevalence of the loss of the PIV following blood collection was also measured. Findings included one clotted specimen, success rate of 91.3%, and 1.3% of PIVs becoming non-functional after collection. Obtaining blood specimens from a pre-existing PIV should be considered in a pediatric patient. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Antimony susceptibility of Leishmania isolates collected over a 30-year period in Algeria.

    Science.gov (United States)

    Eddaikra, Naouel; Ait-Oudhia, Khatima; Kherrachi, Ihcen; Oury, Bruno; Moulti-Mati, Farida; Benikhlef, Razika; Harrat, Zoubir; Sereno, Denis

    2018-03-01

    In Algeria, the treatment of visceral and cutaneous leishmanioses (VL and CL) has been and continues to be based on antimony-containing drugs. It is suspected that high drug selective pressure might favor the emergence of chemoresistant parasites. Although treatment failure is frequently reported during antimonial therapy of both CL and VL, antimonial resistance has never been thoroughly investigated in Algeria. Determining the level of antimonial susceptibility, amongst Leishmania transmitted in Algeria, is of great importance for the development of public health policies. Within the framework of the knowledge about the epidemiology of VL and CL amassed during the last 30 years, we sampled Leishmania isolates to determine their susceptibility to antimony. We analyzed a total of 106 isolates including 88 isolates collected between 1976 and 2013 in Algeria from humans, dogs, rodents, and phlebotomines and 18 collected from dogs in France. All the Algerian isolates were collected in 14 localities where leishmaniasis is endemic. The 50% inhibitory concentrations (IC50) of potassium antimony tartrate (the trivalent form of antimony, Sb(III)) and sodium stibogluconate (the pentavalent form of antimony, Sb(V)) were determined in promastigotes and intramacrophage amastigotes, respectively. The epidemiological cutoff (ECOFF) that allowed us to differentiate between Leishmania species causing cutaneous or visceral leishmaniases that were susceptible (S+) or insusceptible (S-) to the trivalent form of antimony was determined. The computed IC50 cutoff values were 23.83 μg/mL and 15.91 μg/mL for VL and CL, respectively. We report a trend of increasing antimony susceptibility in VL isolates during the 30-year period. In contrast, an increase in the frequency of S- phenotypes in isolates causing CL was observed during the same period. In our study, the emergence of S- phenotypes correlates with the inclusion of L. killicki (syn: L. tropica) isolates that cause cutaneous

  18. Botanical collecting activity in the area of the Flora of Ethiopia and Eritrea during the "motor period"

    DEFF Research Database (Denmark)

    Friis, Ib

    2011-01-01

    The account summarizes the botanical field work in Eritrea and Ethiopia since the 1930s, in the period when motor cars have been used for transport of equipment and collections, as opposed to the "heroic" period, when pack animals were used. The use of cars for botanical collecting in Eritrea and...

  19. IMPROVEMENT OF METHODS FOR HYDROBIOLOGICAL RESEARCH AND MODIFICATION OF STANDARD TOOLS FOR SAMPLE COLLECTION

    Directory of Open Access Journals (Sweden)

    M. M. Aligadjiev

    2015-01-01

    Full Text Available Aim. The paper discusses the improvement of methods of hydrobiological studies by modifying tools for plankton and benthic samples collecting. Methods. In order to improve the standard methods of hydro-biological research, we have developed tools for sampling zooplankton and benthic environment of the Caspian Sea. Results. Long-term practice of selecting hydrobiological samples in the Caspian Sea shows that it is required to complete the modernization of the sampling tools used to collect hydrobiological material. With the introduction of Azov and Black Sea invasive comb jelly named Mnemiopsis leidyi A. Agassiz to the Caspian Sea there is a need to collect plankton samples without disturbing its integrity. Tools for collecting benthic fauna do not always give a complete picture of the state of benthic ecosystems because of the lack of visual site selection for sampling. Moreover, while sampling by dredge there is a probable loss of the samples, especially in areas with difficult terrain. Conclusion. We propose to modify a small model of Upstein net (applied in shallow water to collect zooplankton samples with an upper inverted cone that will significantly improve the catchability of the net in theCaspian Sea. Bottom sampler can be improved by installing a video camera for visual inspection of the bottom topography, and use sensors to determine tilt of the dredge and the position of the valves of the bucket. 

  20. Impact of collection conditions on the metabolite content of human urine samples as analyzed by liquid chromatography coupled to mass spectrometry and nuclear magnetic resonance spectroscopy.

    Science.gov (United States)

    Roux, Aurélie; Thévenot, Etienne A; Seguin, François; Olivier, Marie-Françoise; Junot, Christophe

    There is a lack of comprehensive studies documenting the impact of sample collection conditions on metabolic composition of human urine. To address this issue, two experiments were performed at a 3-month interval, in which midstream urine samples from healthy individuals were collected, pooled, divided into several aliquots and kept under specific conditions (room temperature, 4 °C, with or without preservative) up to 72 h before storage at -80 °C. Samples were analyzed by high-performance liquid chromatography coupled to high-resolution mass spectrometry and bacterial contamination was monitored by turbidimetry. Multivariate analyses showed that urinary metabolic fingerprints were affected by the presence of preservatives and also by storage at room temperature from 24 to 72 h, whereas no change was observed for urine samples stored at 4 °C over a 72-h period. Investigations were then focused on 280 metabolites previously identified in urine: 19 of them were impacted by the kind of sample collection protocol in both experiments, including 12 metabolites affected by bacterial contamination and 7 exhibiting poor chemical stability. Finally, our results emphasize that the use of preservative prevents bacterial overgrowth, but does not avoid metabolite instability in solution, whereas storage at 4 °C inhibits bacterial overgrowth at least over a 72-h period and slows the chemical degradation process. Consequently, and for further LC/MS analyses, human urine samples should be kept at 4 °C if their collection is performed over 24 h.

  1. Human blood RNA stabilization in samples collected and transported for a large biobank

    Science.gov (United States)

    2012-01-01

    Background The Norwegian Mother and Child Cohort Study (MoBa) is a nation-wide population-based pregnancy cohort initiated in 1999, comprising more than 108.000 pregnancies recruited between 1999 and 2008. In this study we evaluated the feasibility of integrating RNA analyses into existing MoBa protocols. We compared two different blood RNA collection tube systems – the PAXgene™ Blood RNA system and the Tempus™ Blood RNA system - and assessed the effects of suboptimal blood volumes in collection tubes and of transportation of blood samples by standard mail. Endpoints to characterize the samples were RNA quality and yield, and the RNA transcript stability of selected genes. Findings High-quality RNA could be extracted from blood samples stabilized with both PAXgene and Tempus tubes. The RNA yields obtained from the blood samples collected in Tempus tubes were consistently higher than from PAXgene tubes. Higher RNA yields were obtained from cord blood (3 – 4 times) compared to adult blood with both types of tubes. Transportation of samples by standard mail had moderate effects on RNA quality and RNA transcript stability; the overall RNA quality of the transported samples was high. Some unexplained changes in gene expression were noted, which seemed to correlate with suboptimal blood volumes collected in the tubes. Temperature variations during transportation may also be of some importance. Conclusions Our results strongly suggest that special collection tubes are necessary for RNA stabilization and they should be used for establishing new biobanks. We also show that the 50,000 samples collected in the MoBa biobank provide RNA of high quality and in sufficient amounts to allow gene expression analyses for studying the association of disease with altered patterns of gene expression. PMID:22988904

  2. Collection and preparation of water samples for hydrogeochemical reconnaissance

    International Nuclear Information System (INIS)

    Baucom, E.I.; Ferguson, R.B.; Wallace, R.M.

    1977-01-01

    A method based on ion exchange and neutron activation analysis (NAA) was developed and field-tested to determine uranium over the range 0.02 to 10,000 ppb in natural water using a single procedure. Water samples are filtered in the field using a specially-designed one-liter filter apparatus pressurized to 40 psig with an inert gas. The filtered water is treated with a high purity, mixed cation-anion resin in the hydronium-hydroxide form. All ions are removed from solution under the strong driving force of the neutralization reaction. Anionic, cationic, and natural complexes of uranium can be concentrated with this method. Field tests showed greater than 95 percent recovery of 13 elements analyzed (including greater than 99 percent recovery of uranium) and greater than or equal to 90 percent recovery of 4 other elements. Uranium collected on the resin was quantitatively determined by NAA. Coefficient of variation for sampling plus analysis was less than 20 percent for samples containing more than 0.1 ppb uranium. Advantages of this method include: (1) wide dynamic range, (2) low detection limit for uranium (0.02 ppb), (3) high precision and accuracy, (4) relatively low cost, (5) high-yield recovery from low-level aqueous samples without risk of loss to containers, (6) decreased risk of significant sample contamination compared with other low-level methods, (7) production of stable samples suitable for retrievable storage, and(8) concentration of other ions that can be determined by NAA. This paper presents (1) background regarding development of procedures for sample collection and preparation, (2) results of development programs, (3) description of equipment and field procedures, and (4) preliminary conclusions regarding use of this technology for hydrogeochemical reconnaissance for uranium

  3. Concentration and characteristics of depleted uranium in water, air and biological samples collected in Serbia and Montenegro

    International Nuclear Information System (INIS)

    Jia Guogang; Belli, Maria; Sansone, Umberto; Rosamilia, Silvia; Gaudino, Stefania

    2005-01-01

    During the Balkan conflicts, in 1995 and 1999, depleted uranium (DU) rounds were employed and were left in the battlefield. Health concern is related to the risk arising from contamination of the environment with DU penetrators and dust. In order to evaluate the impact of DU on the environment and population in Serbia and Montenegro, radiological surveys of DU in water, air and biological samples were carried out over the period 27 October-5 November 2001. The uranium isotopic concentrations in biological samples collected in Serbia and Montenegro, mainly lichens and barks, were found to be in the range of 0.67-704 Bq kg -1 for 238 U, 0.48-93.9 Bq kg -1 for 234 U and 0.02-12.2 Bq kg -1 for 235 U, showing uranium levels to be higher than in the samples collected at the control sites. Moreover, 236 U was detectable in some of the samples. The isotopic ratios of 234 U/ 238 U showed DU to be detectable in many biological samples at all examined sites, especially in Montenegro, indicating widespread ground-surface DU contamination, albeit at very low level. The uranium isotopic concentrations in air obtained from the air filter samples collected in Serbia and Montenegro were found to be in the range of 1.99-42.1 μBq m -3 for 238 U, 0.96-38.0 μBq m -3 for 234 U, and 0.05-1.83 μBq m -3 for 235 U, being in the typical range of natural uranium values. Thus said, most of the air samples are DU positive, this fact agreeing well with the widespread DU contamination detected in the biological samples. The uranium concentrations in water samples collected in Serbia and Montenegro were found to be in the range of 0.40-21.9 mBq l -1 for 238 U, 0.27-28.1 mBq l -1 for 234 U, and 0.01-0.88 mBq l -1 for 235 U, these values being much lower than those in mineral water found in central Italy and below the WHO guideline for drinking water. From a radiotoxicological point of view, at this moment there is no significant radiological risk related to these investigated sites in terms of

  4. Concentration and characteristics of depleted uranium in water, air and biological samples collected in Serbia and Montenegro.

    Science.gov (United States)

    Jia, Guogang; Belli, Maria; Sansone, Umberto; Rosamilia, Silvia; Gaudino, Stefania

    2005-09-01

    During the Balkan conflicts, in 1995 and 1999, depleted uranium (DU) rounds were employed and were left in the battlefield. Health concern is related to the risk arising from contamination of the environment with DU penetrators and dust. In order to evaluate the impact of DU on the environment and population in Serbia and Montenegro, radiological surveys of DU in water, air and biological samples were carried out over the period 27 October-5 November 2001. The uranium isotopic concentrations in biological samples collected in Serbia and Montenegro, mainly lichens and barks, were found to be in the range of 0.67-704 Bqkg(-1) for (238)U, 0.48-93.9 Bqkg(-1) for (234)U and 0.02-12.2 Bqkg(-1) for (235)U, showing uranium levels to be higher than in the samples collected at the control sites. Moreover, (236)U was detectable in some of the samples. The isotopic ratios of (234)U/(238)U showed DU to be detectable in many biological samples at all examined sites, especially in Montenegro, indicating widespread ground-surface DU contamination, albeit at very low level. The uranium isotopic concentrations in air obtained from the air filter samples collected in Serbia and Montenegro were found to be in the range of 1.99-42.1 microBqm(-3) for (238)U, 0.96-38.0 microBqm(-3) for (234)U, and 0.05-1.83 microBqm(-3) for (235)U, being in the typical range of natural uranium values. Thus said, most of the air samples are DU positive, this fact agreeing well with the widespread DU contamination detected in the biological samples. The uranium concentrations in water samples collected in Serbia and Montenegro were found to be in the range of 0.40-21.9 mBql(-1) for (238)U, 0.27-28.1 mBql(-1) for (234)U, and 0.01-0.88 mBql(-1) for (235)U, these values being much lower than those in mineral water found in central Italy and below the WHO guideline for drinking water. From a radiotoxicological point of view, at this moment there is no significant radiological risk related to these investigated

  5. Blood venous sample collection: Recommendations overview and a checklist to improve quality.

    Science.gov (United States)

    Giavarina, Davide; Lippi, Giuseppe

    2017-07-01

    The extra-analytical phases of the total testing process have substantial impact on managed care, as well as an inherent high risk of vulnerability to errors which is often greater than that of the analytical phase. The collection of biological samples is a crucial preanalytical activity. Problems or errors occurring shortly before, or soon after, this preanalytical step may impair sample quality and characteristics, or else modify the final results of testing. The standardization of fasting requirements, rest, patient position and psychological state of the patient are therefore crucial for mitigating the impact of preanalytical variability. Moreover, the quality of materials used for collecting specimens, along with their compatibility, can guarantee sample quality and persistence of chemical and physical characteristics of the analytes over time, so safeguarding the reliability of testing. Appropriate techniques and sampling procedures are effective to prevent problems such as hemolysis, undue clotting in the blood tube, draw of insufficient sample volume and modification of analyte concentration. An accurate identification of both patient and blood samples is a key priority as for other healthcare activities. Good laboratory practice and appropriate training of operators, by specifically targeting collection of biological samples, blood in particular, may greatly improve this issue, thus lowering the risk of errors and their adverse clinical consequences. The implementation of a simple and rapid check-list, including verification of blood collection devices, patient preparation and sampling techniques, was found to be effective for enhancing sample quality and reducing some preanalytical errors associated with these procedures. The use of this tool, along with implementation of objective and standardized systems for detecting non-conformities related to unsuitable samples, can be helpful for standardizing preanalytical activities and improving the quality of

  6. The Autism Simplex Collection : an international, expertly phenotyped autism sample for genetic and phenotypic analyses

    OpenAIRE

    Buxbaum, Joseph D.; Bolshakova, Nadia; Brownfeld, Jessica M.; Anney, Richard J. L.; Bender, Patrick; Bernier, Raphael; Cook, Edwin H.; Coon, Hilary; Cuccaro, Michael L.; Freitag, Christine M.; Hallmayer, Joachim; Geschwind, Daniel H.; Klauck, Sabine M.; Nurnberger, John I.; Oliveira, Guiomar

    2014-01-01

    Background: There is an urgent need for expanding and enhancing autism spectrum disorder (ASD) samples, in order to better understand causes of ASD. Methods: In a unique public-private partnership, 13 sites with extensive experience in both the assessment and diagnosis of ASD embarked on an ambitious, 2-year program to collect samples for genetic and phenotypic research and begin analyses on these samples. The program was called The Autism Simplex Collection (TASC). TASC sample collection ...

  7. Activity Concentration for Surface Soil Samples Collected from Arrant, Qena, Egypt

    International Nuclear Information System (INIS)

    Harb, S.; Salahel Din, K.; Abbady, A.; Moustafa, M.

    2010-01-01

    Soil samples were collected from four regions from Armant area. Qena, Upper Egypt for measure their natural radioactivity concentrations due to Ra-226, Th-232 and K-40 radionuclides. Thirty-Four surface soil samples were analyzed by using low-level gamma-spectrometric analysis. The average activity concentration for Ra-226 in (Bq/kg) in the collected soil samples were found to be 27.3 ±3.2, 11.4±1.09, 10.6±1.2, and 11.4±1.02 while the average value for Th-232 were 15.1±1.4, 11.1±0.77, 10.8 ± 0.72 and 11.1 ± 0.8 (Bq/kg) for soil samples from North, South, West and East. The corresponding average values for K-40 were 521.4±16.8, 463±14.8, 488.9±15.6 and 344.5±10.7 (Bq/kg), respectively. Based on radionuclides concentration in surface soil samples the radiological effects can be assessed

  8. An international study of the performance of sample collection from patients

    NARCIS (Netherlands)

    Dzik, WH; Murphy, MF; Andreu, G; Heddle, N; Hogman, C; Kekomaki, R; Murphy, S; Shimizu, M; Smit Sibinga, C.T.

    2003-01-01

    Background and Objectives Collection of a blood sample from the correct patient is the first step in the process of safe transfusion. The aim of this international collaborative study was to assess the frequency of mislabelled and miscollected samples drawn for blood grouping. Materials and Methods

  9. Equipment for collecting samples of radioactive solutions; Installation de prelevements d'echantillons de solutions radioactives

    Energy Technology Data Exchange (ETDEWEB)

    Raggenbass, A.; Fradin, J.; Joubert, G.

    1958-12-03

    The authors present an equipment aimed at collecting samples of fission products to perform radio-chemical analysis. As the sample must have a total activity between 1 and 50 micro-Curie, this installation comprises a sampling system and a dilution device which aims at bringing the sample to the suitable activity. Samples are collected by means of needles. The sample reproducibility is discussed. The dilution device is described.

  10. The calculation of collective energies from periodic time-dependent Hartree-Fock solutions

    International Nuclear Information System (INIS)

    Zahed, I.; Baranger, M.

    1983-06-01

    A periodic TDHF solution is used as the reference state for a diagrammatic expansion of the propagator. A discrete Fourier transform leads to a function of energy, whose poles are the corresponding energy levels. Limiting the expansion to first-order diagrams leads to a new derivation of the Bohr-Sommerfeld-like quantization rule for collective states

  11. Disposable collection kit for rapid and reliable collection of saliva.

    Science.gov (United States)

    Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek

    2015-01-01

    To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 μl) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method on subsequent immunoassay results was verified by assessing salivary cortisol levels in the samples and comparing them to controls. The recovered volumes for the whole saliva samples were 3.85 ± 0.28, 10.79 ± 0.95, and 31.18 ± 1.72 μl, respectively (CV = 8.76%) and 2.91 ± 0.19, 9.75 ± 0.43, and 29.64 ± 0.91 μl, respectively, (CV = 6.36%) for the controls. There was a close correspondence between the salivary cortisol levels from the saliva samples obtained by the collection kit and the controls (R(2)  > 0.96). The disposable saliva collection kit allows accurate and repeatable collection of fixed amounts of whole saliva and does not interfere with subsequent measurements of salivary cortisol. The simple collection process, lack of elaborate specimen recovery steps, and the short turnaround time (<3 min) should render the kit attractive to test subjects and researchers alike. © 2015 Wiley Periodicals, Inc.

  12. Improved sperm kinematics in semen samples collected after 2 h versus 4-7 days of ejaculation abstinence.

    Science.gov (United States)

    Alipour, H; Van Der Horst, G; Christiansen, O B; Dardmeh, F; Jørgensen, N; Nielsen, H I; Hnida, C

    2017-07-01

    Does a short abstinence period of only 2 h yield spermatozoa with better motility characteristics than samples collected after 4-7 days? Despite lower semen volume, sperm concentration, total sperm counts and total motile counts, higher percentages of motile spermatozoa with higher velocity and progressiveness were detected in samples obtained after 2 h. Most studies that have assessed the effect of abstinence periods on sperm motility parameters in men with a sperm concentration below 15 million/ml have detected a higher percentage of motile spermatozoa in samples obtained after short abstinence periods. Studies of men with sperm concentrations above 15 million/ml have reported significantly decreased motile sperm counts after 24 h of abstinence compared with longer abstinence periods. This study had a controlled repeated-measures design based on semen samples from 43 male partners, in couples attending for IVF treatment, who had a sperm concentration above 15 million/ml. Data were collected between June 2014 and December 2015 in the Fertility Unit of Aalborg University Hospital (Aalborg, Denmark). Participants provided a semen sample after 4-7 days of abstinence followed by another sample after only 2 h. For both ejaculates, sperm concentration, total sperm counts, motility groups and detailed kinematic parameters were assessed and compared by using the Sperm Class Analyzer (SCA) computer-aided sperm analysis system before and after density gradient selection. The laboratory's local manual method (Makler chamber) was used for comparison. The second raw ejaculate demonstrated lower semen volume (P sperm concentration (P = 0.003) and sperm counts in all motility sub-groups (P sperm concentration and total sperm counts in all motility sub-groups, the significantly higher percentage of spermatozoa with better motility characteristics (velocity, progressiveness and hyperactivation) in the second ejaculate, may provide and allow for a simpler and more effective

  13. PIXE Analysis of Aerosol and Soil Samples Collected in the Adirondack Mountains

    Science.gov (United States)

    Yoskowitz, Joshua; Ali, Salina; Nadareski, Benjamin; Labrake, Scott; Vineyard, Michael

    2014-09-01

    We have performed an elemental analysis of aerosol and soil samples collected at Piseco Lake in Upstate New York using proton induced X-ray emission spectroscopy (PIXE). This work is part of a systematic study of airborne pollution in the Adirondack Mountains. Of particular interest is the sulfur content that can contribute to acid rain, a well-documented problem in the Adirondacks. We used a nine-stage cascade impactor to collect the aerosol samples near Piseco Lake and distribute the particulate matter onto Kapton foils by particle size. The soil samples were also collected at Piseco Lake and pressed into cylindrical pellets for experimentation. PIXE analysis of the aerosol and soil samples were performed with 2.2-MeV proton beams from the 1.1-MV Pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. There are higher concentrations of sulfur at smaller particle sizes (0.25-1 μm), suggesting that it could be suspended in the air for days and originate from sources very far away. Other elements with significant concentrations peak at larger particle sizes (1-4 μm) and are found in the soil samples, suggesting that these elements could originate in the soil. The PIXE analysis will be described and the resulting data will be presented.

  14. Advanced Curation Activities at NASA: Implications for Astrobiological Studies of Future Sample Collections

    Science.gov (United States)

    McCubbin, F. M.; Evans, C. A.; Fries, M. D.; Harrington, A. D.; Regberg, A. B.; Snead, C. J.; Zeigler, R. A.

    2017-01-01

    The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10F JSC is charged with curation of all extraterrestrial material under NASA control, including future NASA missions. The Directive goes on to define Curation as including documentation, preservation, preparation, and distribution of samples for re-search, education, and public outreach. Here we briefly describe NASA's astromaterials collections and our ongoing efforts related to enhancing the utility of our current collections as well as our efforts to prepare for future sample return missions. We collectively refer to these efforts as advanced curation.

  15. 77 FR 38323 - Proposed Extension of Existing Information Collection; Respirable Coal Mine Dust Sampling

    Science.gov (United States)

    2012-06-27

    ... Information Collection; Respirable Coal Mine Dust Sampling AGENCY: Mine Safety and Health Administration... Sampling'' to more accurately reflect the type of information that is collected. Chronic exposure to... dust levels since 1970 and, consequently, the prevalence rate of black lung among coal miners, severe...

  16. Acceptability of self-collected vaginal samples for HPV testing in an ...

    African Journals Online (AJOL)

    Objective: To evaluate the acceptability of self-collected vaginal samples for HPV testing in women living in rural and urban areas of ... Conclusion: Acceptability of self-sampling for HPV testing was similarly excellent in both groups despite their difference in terms ... cancer is the leading cause of death caused by cancer in.

  17. Psychostimulant use among college students during periods of high and low stress: an interdisciplinary approach utilizing both self-report and unobtrusive chemical sample data.

    Science.gov (United States)

    Moore, David R; Burgard, Daniel A; Larson, Ramsey G; Ferm, Mikael

    2014-05-01

    This study quantified psychostimulant use patterns over periods of high and low stress from both self-report measures and chemical wastewater analyses and identified possible predictors of psychostimulant abuse on a college campus. Self-report data were collected at three times of varying stress levels throughout one college semester: during the first week of school (N=676), midterms (N=468), and shortly before final exams (N=400). Campus wastewater samples were collected over 72-hour periods during the same time frames as the surveys. The metabolites of Adderall and Ritalin were quantified through solid phase extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Samples were normalized with creatinine. Evidence was found to suggest an increase in psychostimulant use during periods of stress, with significant differences found from self-report data between the first week and midterms and from chemical data between these same two assessment periods as well as between the first week of classes and finals. Key predictors of lifetime non-prescriptive psychostimulant use included self-reported procrastination and poor time-management, use of other substances (especially nicotine/tobacco, alcohol, and cocaine), and students' perception of non-prescriptive psychostimulant use as normative on campus. The findings shed further light on psychostimulant use patterns among college students, particularly as a function of stress; the study also highlights the benefit of utilizing an interdisciplinary approach that uses both subjective and objective empirical data. The results have implications for prevention/intervention programs on college campuses designed to reduce stress and facilitate healthier coping. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Trace Elements Analysis of Archeological Brick Samples Collected from Different Historical Placs in Rajshahi Division

    International Nuclear Information System (INIS)

    Begum, Bilkis A.; Biswas, Shapan K.; Matin, Mohammed A.; Hoque, Mohammed M.; Hopke, Philip K.

    2007-01-01

    Twenty-nine brick samples were collected from different temples and palaces, namely Paharpur, Kumarpur, Gaurbari, Puthia and Natore in Rajshahi Division in Bangladesh. The samples were analyzed by X-ray Fluorescence (XRF) method. The elemental data sets have been analyzed in order to find out the general characteristics and any significant differences among the collected samples and identify the origin of these brick samples. Most of the crustal elements have enrichment factor (EF) values close to unity. Only Cu and Pb have high values that may come from painting as these have been collected from temples and palaces.(author)

  19. A comparison of human papillomavirus testing of clinician-collected and self-collected samples during follow-up after screen-and-treat.

    Science.gov (United States)

    Taylor, Sylvia; Wang, Chunhui; Wright, Thomas C; Denny, Lynette; Kuhn, Louise

    2011-08-15

    Screen-and-treat cervical cancer prevention programs based on high-risk human papillomavirus (HPV) testing and cryotherapy have been shown to be effective in resource-limited settings. However, because cryotherapy is not 100% effective, follow-up is needed after treatment to detect post-treatment failures. We compared the test performances of high-risk HPV testing (Hybrid Capture 2) using self-collected and clinician-collected samples as well as cervical cytology for identifying cervical intraepithelial neoplasia grades 2 or 3 or invasive cervical cancer (CIN2+) among women who did (n=812) and did not (n=1858) undergo cryotherapy in a South African screen-and-treat trial. At 6 months after enrolment (and after cryotherapy, if performed), women were tested using all three screening methods and then underwent colposcopy/biopsy. A predefined subset of women (n=1,455) had extended follow-up with colposcopy/biopsy at 12 months. A total of 33 and 91 cases of CIN2+ were detected among treated and untreated women, respectively. The sensitivity of HPV testing using clinician-collected samples and cervical cytology did not differ by treatment status. HPV testing of clinician-collected samples detected the most cases of CIN2+ among both treated (85%) and untreated (91%) women (p=0.31). Cytology (at a cutoff of atypical squamous cells of undetermined significance or greater) detected 76% of cases among both treated and untreated women. However, the sensitivity of HPV testing using self-collected samples was significantly lower among treated versus untreated women (55% vs. 78%, p=0.01). HPV testing using self-collected vaginal specimens may be useful in primary screening but performs poorly for detecting post-treatment failures. Copyright © 2010 UICC.

  20. Methods for collecting algal samples as part of the National Water-Quality Assessment Program

    Science.gov (United States)

    Porter, Stephen D.; Cuffney, Thomas F.; Gurtz, Martin E.; Meador, Michael R.

    1993-01-01

    Benthic algae (periphyton) and phytoplankton communities are characterized in the U.S. Geological Survey's National Water-Quality Assessment Program as part of an integrated physical, chemical, and biological assessment of the Nation's water quality. This multidisciplinary approach provides multiple lines of evidence for evaluating water-quality status and trends, and for refining an understanding of the factors that affect water-quality conditions locally, regionally, and nationally. Water quality can be characterized by evaluating the results of qualitative and quantitative measurements of the algal community. Qualitative periphyton samples are collected to develop of list of taxa present in the sampling reach. Quantitative periphyton samples are collected to measure algal community structure within selected habitats. These samples of benthic algal communities are collected from natural substrates, using the sampling methods that are most appropriate for the habitat conditions. Phytoplankton samples may be collected in large nonwadeable streams and rivers to meet specific program objectives. Estimates of algal biomass (chlorophyll content and ash-free dry mass) also are optional measures that may be useful for interpreting water-quality conditions. A nationally consistent approach provides guidance on site, reach, and habitat selection, as well as information on methods and equipment for qualitative and quantitative sampling. Appropriate quality-assurance and quality-control guidelines are used to maximize the ability to analyze data locally, regionally, and nationally.

  1. Simultaneous PIXE and PIGE analyses of aerosol samples collected in urban areas

    International Nuclear Information System (INIS)

    Boni, C.; Caruso, E.; Cereda, E.; Marcazzan, G.M.; Redaelli, P.; Bacci, P.

    1988-01-01

    The paper concerns the simultaneous PIXE (Particle Induced X-ray Emission) and PIGE (Proton Induced Gamma-ray Emission) analyses of aerosol samples collected in urban areas. The results show that PIGE can detect Li, F, Na, Al, and Si in fly ashes and F, Na, Al and Si in atmospheric aerosol. The PIXE-PIGE technique has also been applied to 80 samples of atmospheric particular matter collected above Milan during the winter and summer months of 1986/7, and the average values of concentrations and enrichment factors are given for the detected elements. (U.K.)

  2. Assembly for collecting samples for purposes of identification or analysis and method of use

    Science.gov (United States)

    Thompson, Cyril V [Knoxville, TN; Smith, Rob R [Knoxville, TN

    2010-02-02

    An assembly and an associated method for collecting a sample of material desired to be characterized with diagnostic equipment includes or utilizes an elongated member having a proximal end with which the assembly is manipulated by a user and a distal end. In addition, a collection tip which is capable of being placed into contact with the material to be characterized is supported upon the distal end. The collection tip includes a body of chemically-inert porous material for binding a sample of material when the tip is placed into contact with the material and thereby holds the sample of material for subsequent introduction to the diagnostic equipment.

  3. Comparative multielement analyses of airborne particulate samples collected in various areas

    International Nuclear Information System (INIS)

    Mamuro, Tetsuo; Matsuda, Yatsuka; Mizohata, Akira

    1973-01-01

    In order to grasp the characteristic features of the air pollution by particulates in various areas in Japan, multielement analyses by instrumental neutron activation analysis and radioisotope energy dispersive X-ray fluorescence analysis were applied to 31 airborne particulate samples collected in 15 different areas, and the analytical results obtained were compared with one another. All the samples were collected by so-called ''10 micron cut'' samplers, the collection efficiency of which is considered to be 50% at 8μ and nearly zero beyond 10μ. Among the areas in question there are clean seaside areas, heavily industrialized areas, small cities along the Inland Sea or the Pacific Ocean around which industrialization is progressing, a small city having only a big iron work, an area famous for its ceramic industry and so on. The atmospheres over them were found to be quite different not only in pollution extent but also in pollution pattern. (auth.)

  4. Characteristics of the samples in the FNG fission deposit collection

    Energy Technology Data Exchange (ETDEWEB)

    Meadows, J.W.

    1990-12-01

    Information concerning the samples in the Fast Neutron Generator (FNG) Group's fission deposit collection has been assembled. This includes the physical dimensions, isotopic analyses, half-lives, alpha emission rates specific activities and deposit weights. 10 refs., 9 figs., 5 tabs.

  5. A comparison of results for samples collected with bailers constructed of different materials

    International Nuclear Information System (INIS)

    Thomey, N.; Ogle, R.; Jackson, J.

    1992-01-01

    A bailer is one of the most common sampling devices used to collect ground water samples. Bailers constructed from various materials are available; teflon, polyvinyl chloride (PVC), polyethylene, and stainless steel are all commonly used. It is widely recognized that sample results can be affected by the material from which the bailer is constructed. Teflon and stainless steel are usually recommended based upon their inert properties. The cost of these bailers is significantly higher than other types. For the purposes of petroleum storage tank investigations, sampling devices that would not compromise sample quality but be more economical than teflon or stainless steel would be especially desirable. Water samples were collected using the different types of bailers; teflon, stainless steel, PVC, and polyethylene. Split samples were analyzed for benzene, toluene, ethylbenzene, total xylenes, and Total Petroleum Hydrocarbons. The analytical results were compared to determine if differences were due to normal analytical variances or due to interaction of the sample with the sampling device. No difference was noted in the results which were obtained

  6. Application of bar codes to the automation of analytical sample data collection

    International Nuclear Information System (INIS)

    Jurgensen, H.A.

    1986-01-01

    The Health Protection Department at the Savannah River Plant collects 500 urine samples per day for tritium analyses. Prior to automation, all sample information was compiled manually. Bar code technology was chosen for automating this program because it provides a more accurate, efficient, and inexpensive method for data entry. The system has three major functions: sample labeling is accomplished at remote bar code label stations composed of an Intermec 8220 (Intermec Corp.) interfaced to an IBM-PC, data collection is done on a central VAX 11/730 (Digital Equipment Corp.). Bar code readers are used to log-in samples to be analyzed on liquid scintillation counters. The VAX 11/730 processes the data and generates reports, data storage is on the VAX 11/730 and backed up on the plant's central computer. A brief description of several other bar code applications at the Savannah River Plant is also presented

  7. Sample collection: an overview of the Hydrogeochemical and Stream Sediment Reconnaissance Program

    International Nuclear Information System (INIS)

    Bolivar, S.L.

    1979-01-01

    A Hydrogeochemical and Stream Sediment Reconnaissance (HSSR) for uranium is currently being conducted throughout the conterminous United States and Alaska. The HSSR is part of the National Uranium Resource Evaluation sponsored by the US Department of Energy. This ambitious geochemical reconnaissance program is conducted by four national laboratories: Los Alamos Scientific Laboratory, Lawrence Livermore Laboratory, Oak Ridge Gaseous Diffusion Plant, and Savannah River Laboratory. The program is based on an extensive review of world literature, reconnaissance work done in other countries, and pilot studies conducted by each laboratory. Sample-collection methods and sample density are determined to optimize the probability of detecting potential uranium mineralization. To achieve this aim, each laboratory has developed independent standardized field collection procedures that are designed for its section of the country. Field parameters such as pH, conductivity, climate, geography, and geology are recorded at each site. Most samples are collected at densities of one sample site per 10 to 23 km 2 . The HSSR program has helped to improve existing hydrogeochemical reconnaissance exploration techniques. In addition to providing industry with data that may help to identify potential uranium districts and to extend known uranium provinces, the HSSR also provides multi-element analytical data, which can be used in water quality, soil, sediment, environmental, and base-metal exploration studies

  8. The Importance of Meteorite Collections to Sample Return Missions: Past, Present, and Future Considerations

    Science.gov (United States)

    Welzenbach, L. C.; McCoy, T. J.; Glavin, D. P.; Dworkin, J. P.; Abell, P. A.

    2012-01-01

    While much of the scientific community s current attention is drawn to sample return missions, it is the existing meteorite and cosmic dust collections that both provide the paradigms to be tested by these missions and the context for interpreting the results. Recent sample returns from the Stardust and Hayabusa missions provided us with new materials and insights about our Solar System history and processes. As an example, Stardust sampled CAIs among the population of cometary grains, requiring extensive and unexpected radial mixing in the early solar nebula. This finding would not have been possible, however, without extensive studies of meteoritic CAIs that established their high-temperature, inner Solar System formation. Samples returned by Stardust also revealed the first evidence of a cometary amino acid, a discovery that would not have been possible with current in situ flight instrument technology. The Hayabusa mission provided the final evidence linking ordinary chondrites and S asteroids, a hypothesis that developed from centuries of collection and laboratory and ground-based telescopic studies. In addition to these scientific findings, studies of existing meteorite collections have defined and refined the analytical techniques essential to studying returned samples. As an example, the fortuitous fall of the Allende CV3 and Murchison CM2 chondrites within months before the return of Apollo samples allowed testing of new state-of-the-art analytical facilities. The results of those studies not only prepared us to better study lunar materials, but unanticipated discoveries changed many of our concepts about the earliest history and processes of the solar nebula. This synergy between existing collections and future space exploration is certainly not limited to sample return missions. Laboratory studies confirmed the existence of meteorites from Mars and raised the provocative possibility of preservation of ancient microbial life. The laboratory studies in

  9. Wuchereria bancrofti in Tanzania: microfilarial periodicity and effect of blood sampling time on microfilarial intensities

    DEFF Research Database (Denmark)

    Simonsen, Poul Erik; Niemann, L.; Meyrowitsch, Dan Wolf

    1997-01-01

    The circadian periodicity of Wuchereria bancrofti microfilarial (mf) intensities in peripheral blood was analysed in a group of infected individuals from an endemic community in north-eastern Tanzania. The mf density was quantified at two-hourly intervals for 24 hours. A clear nocturnal periodic...... of blood sampling before peak time is discussed, and the importance of taking sampling time into consideration when analysing data from epidemiological studies is emphasized. A simple method is devised which can be used to adjust for the influence of time on mf intensities, in studies where accurate...... information on mf intensities is necessary, and where it is impossible to obtain all samples at peak time....

  10. Collection and preparation of bottom sediment samples for analysis of radionuclides and trace elements

    International Nuclear Information System (INIS)

    2003-07-01

    The publication is the first in a series of TECDOCs on sampling and sample handling as part of the IAEA support to improve reliability of nuclear analytical techniques (NATs) in Member State laboratories. The purpose of the document is to provide information on the methods for collecting sediments, the equipment used, and the sample preparation techniques for radionuclide and elemental analysis. The most appropriate procedures for defining the strategies and criteria for selecting sampling locations, for sample storage and transportation are also given. Elements of QA/QC and documentation needs for sampling and sediment analysis are discussed. Collection and preparation of stream and river bottom sediments, lake bottom sediments, estuary bottom sediments, and marine (shallow) bottom sediments are covered. The document is intended to be a comprehensive manual for the collection and preparation of bottom sediments as a prerequisite to obtain representative and meaningful results using NATs. Quality assurance and quality control (QA/QC) is emphasized as an important aspect to ensure proper collection, transportation, preservation, and analysis since it forms the basis for interpretation and legislation. Although there are many approaches and methods available for sediment analyses, the scope of the report is limited to sample preparation for (1) analysis of radionuclides (including sediment dating using radionuclides such as Pb-210 and Cs-137) and (2) analysis of trace, minor and major elements using nuclear and related analytical techniques such as NAA, XRF and PIXE

  11. Collection and preparation of bottom sediment samples for analysis of radionuclides and trace elements

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    The publication is the first in a series of TECDOCs on sampling and sample handling as part of the IAEA support to improve reliability of nuclear analytical techniques (NATs) in Member State laboratories. The purpose of the document is to provide information on the methods for collecting sediments, the equipment used, and the sample preparation techniques for radionuclide and elemental analysis. The most appropriate procedures for defining the strategies and criteria for selecting sampling locations, for sample storage and transportation are also given. Elements of QA/QC and documentation needs for sampling and sediment analysis are discussed. Collection and preparation of stream and river bottom sediments, lake bottom sediments, estuary bottom sediments, and marine (shallow) bottom sediments are covered. The document is intended to be a comprehensive manual for the collection and preparation of bottom sediments as a prerequisite to obtain representative and meaningful results using NATs. Quality assurance and quality control (QA/QC) is emphasized as an important aspect to ensure proper collection, transportation, preservation, and analysis since it forms the basis for interpretation and legislation. Although there are many approaches and methods available for sediment analyses, the scope of the report is limited to sample preparation for (1) analysis of radionuclides (including sediment dating using radionuclides such as Pb-210 and Cs-137) and (2) analysis of trace, minor and major elements using nuclear and related analytical techniques such as NAA, XRF and PIXE.

  12. The Consistency of Isotopologues of Ambient Atmospheric Nitric Acid in Passively Collected Samples

    Science.gov (United States)

    Bell, M. D.; Sickman, J. O.; Bytnerowicz, A.; Padgett, P.; Allen, E. B.

    2012-12-01

    Anthropogenic sources of nitrogen oxides have previously been shown to have distinctive isotopic signatures of oxygen and nitrogen. Nylon filters are currently used in passive sampling arrays to measure ambient atmospheric nitric acid concentrations and estimate deposition rates. This experiment measured the ability of nylon filters to consistently collect isotopologues of atmospheric nitric acid in the same ratios as they are present in the atmosphere. Samplers were deployed in continuous stirred tank reactors (CSTR) and at field sites across a nitrogen deposition gradient in Southern California. Filters were exposed over a four week period with individual filters being subjected to 1-4 week exposure times. Extracted nitric acid were measured for δ18O and δ15N ratios and compared for consistency based on length of exposure and amount of HNO3 collected. Filters within the CSTRs collected HNO3 at a consistent rate in both high and low concentration chambers. After two weeks of exposure, the mean δ18O values were within 0.5‰ of the δ18O of the source HNO3 solution. The mean of all weekly exposures were within 0.5‰ of the δ15N of the source solution, but after three weeks, the mean δ15N of adsorbed HNO3 was within 0.2‰. As the length of the exposure increased, the variability of measured delta values decreased for both elements. The field samplers collected HNO3 consistent with previously measured values along a deposition gradient. The mean δ18O at high deposition sites was 52.2‰ compared to 35.7‰ at the low deposition sites. Mean δ15N values were similar at all sites across the deposition gradient. Due to precipitation events occurring during the exposure period, the δ15N and δ18O of nitric acid were highly variable at all field sites. At single sites, changes in δ15N and δ18O were negatively correlated, consistent with two-sourcing mixing dynamics, but the slope of the regressions differed between high and low deposition sites. Anthropogenic

  13. Sources of variability in collection and preparation of paint and lead-coating samples.

    Science.gov (United States)

    Harper, S L; Gutknecht, W F

    2001-06-01

    Chronic exposure of children to lead (Pb) can result in permanent physiological impairment. Since surfaces coated with lead-containing paints and varnishes are potential sources of exposure, it is extremely important that reliable methods for sampling and analysis be available. The sources of variability in the collection and preparation of samples were investigated to improve the performance and comparability of methods and to ensure that data generated will be adequate for its intended use. Paint samples of varying sizes (areas and masses) were collected at different locations across a variety of surfaces including metal, plaster, concrete, and wood. A variety of grinding techniques were compared. Manual mortar and pestle grinding for at least 1.5 min and mechanized grinding techniques were found to generate similar homogenous particle size distributions required for aliquots as small as 0.10 g. When 342 samples were evaluated for sample weight loss during mortar and pestle grinding, 4% had 20% or greater loss with a high of 41%. Homogenization and sub-sampling steps were found to be the principal sources of variability related to the size of the sample collected. Analysis of samples from different locations on apparently identical surfaces were found to vary by more than a factor of two both in Pb concentration (mg cm-2 or %) and areal coating density (g cm-2). Analyses of substrates were performed to determine the Pb remaining after coating removal. Levels as high as 1% Pb were found in some substrate samples, corresponding to more than 35 mg cm-2 Pb. In conclusion, these sources of variability must be considered in development and/or application of any sampling and analysis methodologies.

  14. Collective dose of egyptian atomic energy workers during the period 1991-1995

    Energy Technology Data Exchange (ETDEWEB)

    Gomaa, M A; Youssef, S K [Reactor Division, and Radiation Protect. Dept., Nuclear Reseach Center Atomic Energy Authority, Cairo (Egypt)

    1997-12-31

    The collective dose to egyptian atomic energy authority workers during the period from 1991 - 1995 were statistically evaluated. The personnel dosimetry in use since 1957 for evaluating external exposure doses was mainly the Harwell blue badge and kodak radiation monitoring film for X and Gamma photons. The calibration sensitivity of the badge system was evaluated under the `AL` and/or `Pb/Sn alloy` filters. The results of calibration showed 15% errors in the predicted values for whole body effective doses. The statistical survey showed that the annual collective dose ranged between 0.83-1.54 man Sv. The annual limit of exposure presented 25-58% of the recommended annual limit by ICRP- 60 (1991). Details of the study will be considered in the text. 4 tabs.

  15. Curating NASA's future extraterrestrial sample collections: How do we achieve maximum proficiency?

    Science.gov (United States)

    McCubbin, Francis; Evans, Cynthia; Allton, Judith; Fries, Marc; Righter, Kevin; Zolensky, Michael; Zeigler, Ryan

    2016-07-01

    Introduction: The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10E "Curation of Extraterrestrial Materials", JSC is charged with "The curation of all extraterrestrial material under NASA control, including future NASA missions." The Directive goes on to define Curation as including "…documentation, preservation, preparation, and distribution of samples for research, education, and public outreach." Here we describe some of the ongoing efforts to ensure that the future activities of the NASA Curation Office are working to-wards a state of maximum proficiency. Founding Principle: Curatorial activities began at JSC (Manned Spacecraft Center before 1973) as soon as design and construction planning for the Lunar Receiving Laboratory (LRL) began in 1964 [1], not with the return of the Apollo samples in 1969, nor with the completion of the LRL in 1967. This practice has since proven that curation begins as soon as a sample return mission is conceived, and this founding principle continues to return dividends today [e.g., 2]. The Next Decade: Part of the curation process is planning for the future, and we refer to these planning efforts as "advanced curation" [3]. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of collections as envisioned by NASA exploration goals. We are (and have been) planning for future curation, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, curation of organically- and biologically-sensitive samples, and the use of minimally invasive analytical techniques (e.g., micro-CT, [4]) to characterize samples. These efforts will be useful for Mars Sample Return

  16. Planning for the Collection and Analysis of Samples of Martian Granular Materials Potentially to be Returned by Mars Sample Return

    Science.gov (United States)

    Carrier, B. L.; Beaty, D. W.

    2017-12-01

    NASA's Mars 2020 rover is scheduled to land on Mars in 2021 and will be equipped with a sampling system capable of collecting rock cores, as well as a specialized drill bit for collecting unconsolidated granular material. A key mission objective is to collect a set of samples that have enough scientific merit to justify returning to Earth. In the case of granular materials, we would like to catalyze community discussion on what we would do with these samples if they arrived in our laboratories, as input to decision-making related to sampling the regolith. Numerous scientific objectives have been identified which could be achieved or significantly advanced via the analysis of martian rocks, "regolith," and gas samples. The term "regolith" has more than one definition, including one that is general and one that is much more specific. For the purpose of this analysis we use the term "granular materials" to encompass the most general meaning and restrict "regolith" to a subset of that. Our working taxonomy includes the following: 1) globally sourced airfall dust (dust); 2) saltation-sized particles (sand); 3) locally sourced decomposed rock (regolith); 4) crater ejecta (ejecta); and, 5) other. Analysis of martian granular materials could serve to advance our understanding areas including habitability and astrobiology, surface-atmosphere interactions, chemistry, mineralogy, geology and environmental processes. Results of these analyses would also provide input into planning for future human exploration of Mars, elucidating possible health and mechanical hazards caused by the martian surface material, as well as providing valuable information regarding available resources for ISRU and civil engineering purposes. Results would also be relevant to matters of planetary protection and ground-truthing orbital observations. We will present a preliminary analysis of the following, in order to generate community discussion and feedback on all issues relating to: What are the

  17. Free water {sup 3}H concentration in diet samples collected during 1969-88 in Akita, Japan

    Energy Technology Data Exchange (ETDEWEB)

    Hisamatsu, S. [Institute for Environmental Sciences, Rokkasho, Aomori (Japan); Inoue, Y.; Miyamoto, K. [National Inst. of Radiological Sciences, Chiba (Japan); Takizawa, Y. [National Institute for Minamata Disease, Minamata, Kumamoto (Japan)

    2000-05-01

    Fallout {sup 3}H concentrations in diet samples collected during 1969-88 in Akita Prefecture are reported in this paper. Since {sup 3}H is a potential nuclear fuel for fusion reactors in future, its environmental behavior is important for dose assessment of released {sup 3}H from the plants. Tritium in foods is classified into two types; free water {sup 3}H (FWT) and organically-bound {sup 3}H (OBT). The FWT is practically separated by means of freeze-drying, while the OBT is measured with water sample collected by combustion of dried sample. The OBT concentrations in foods and human tissue samples were reported for {sup 3}H originating from nuclear weapon fallout. We already published {sup 3}H concentrations in diet samples collected in Akita City during 1985-88. Although results for the samples collected in U.S.A. and European countries in the 1970s showed higher specific activity of OBT than FWT, our recent results in Japan indicate almost the same specific activity between them. Since the measurements for the samples in 1960s and 1970s are important to understand the long-term movement of {sup 3}H in the environment, we have searched old diet samples. Recently, diet samples collected in Akita Prefecture during 1969-80 were found and obtained for {sup 3}H analysis. The samples were originally gathered for nutrition survey programs and consisted of duplicate diet samples for 1 day from 10-30 persons. Food samples excluding boiled rice which is the staple food was homogenized by electric mixers after adding tap water. Then, the food and the boiled rice samples were stored in a refrigerator at -20degC. Free water in the samples was collected with lyophilization, then {sup 3}H in the water sample was measured after purification with low-level liquid scintillation counters. The free water {sup 3}H concentrations were measured for 57 diet samples (dish excluding boiled rice) and 17 boiled rice samples. The free water {sup 3}H concentrations in diet and rice samples

  18. Mass-balance modelling results of groundwater data collected at Olkiluoto over the period 2004-2007

    International Nuclear Information System (INIS)

    Partamies, S.; Pitkaenen, P.

    2014-02-01

    Olkiluoto has been selected as a repository site for final disposal of spent nuclear waste produced in Finland. An understanding of the hydrogeochemical groundwater conditions and their evolution is essential in evaluating the long-term safety of the repository. The performance of technical barriers and the migration of potentially released radionuclides depend on the chemical conditions. A prerequisite for understanding these factors is the ability to specify the water-rock interactions, which control chemical conditions in the groundwater. The objective of this study is to present mass-balance studies of the samples collected over the period 2004 - 2007. A total of 178 groundwater samples have been collected over this period (84 groundwater observation tubes, 88 from deep multipackered boreholes and 6 from the ONKALO) which provided a comprehensive dataset on dissolved chemical species and isotopes. The PHREEQC program was used in the mass-balance calculations in order to develop geochemical interpretations of water-rock interactions, isotope-chemical evolution and the mixing of palaeowater types. A model of the hydrogeochemical evolution in different parts of the crystalline bedrock at Olkiluoto has been created and the significance of chemical reactions and groundwater mixing along different flow paths calculated. The changes in hydrogeochemical interpretations and chemical and isotopic calculations indicate that pH seems to be dominantly controlled by thermodynamic equilibrium with calcite in fractures and there are indications that this process may also occur in the overburden layer. Oxic redox conditions, prevailing in recharging groundwater, change abruptly to sulphidic conditions close to the surface, generally in the overburden. The results from the mass-balance calculations correspond and support the earlier conceptions of groundwater mixing, the origin of salinity and the hydrogeochemical evolution. The fractions of glacial meltwater indicated in these

  19. Mass-balance modelling results of groundwater data collected at Olkiluoto over the period 2004-2007

    Energy Technology Data Exchange (ETDEWEB)

    Partamies, S. [VTT Technical Research Centre of Finland, Espoo (Finland); Pitkaenen, P.

    2014-02-15

    Olkiluoto has been selected as a repository site for final disposal of spent nuclear waste produced in Finland. An understanding of the hydrogeochemical groundwater conditions and their evolution is essential in evaluating the long-term safety of the repository. The performance of technical barriers and the migration of potentially released radionuclides depend on the chemical conditions. A prerequisite for understanding these factors is the ability to specify the water-rock interactions, which control chemical conditions in the groundwater. The objective of this study is to present mass-balance studies of the samples collected over the period 2004 - 2007. A total of 178 groundwater samples have been collected over this period (84 groundwater observation tubes, 88 from deep multipackered boreholes and 6 from the ONKALO) which provided a comprehensive dataset on dissolved chemical species and isotopes. The PHREEQC program was used in the mass-balance calculations in order to develop geochemical interpretations of water-rock interactions, isotope-chemical evolution and the mixing of palaeowater types. A model of the hydrogeochemical evolution in different parts of the crystalline bedrock at Olkiluoto has been created and the significance of chemical reactions and groundwater mixing along different flow paths calculated. The changes in hydrogeochemical interpretations and chemical and isotopic calculations indicate that pH seems to be dominantly controlled by thermodynamic equilibrium with calcite in fractures and there are indications that this process may also occur in the overburden layer. Oxic redox conditions, prevailing in recharging groundwater, change abruptly to sulphidic conditions close to the surface, generally in the overburden. The results from the mass-balance calculations correspond and support the earlier conceptions of groundwater mixing, the origin of salinity and the hydrogeochemical evolution. The fractions of glacial meltwater indicated in these

  20. Optimal sampling period of the digital control system for the nuclear power plant steam generator water level control

    International Nuclear Information System (INIS)

    Hur, Woo Sung; Seong, Poong Hyun

    1995-01-01

    A great effort has been made to improve the nuclear plant control system by use of digital technologies and a long term schedule for the control system upgrade has been prepared with an aim to implementation in the next generation nuclear plants. In case of digital control system, it is important to decide the sampling period for analysis and design of the system, because the performance and the stability of a digital control system depend on the value of the sampling period of the digital control system. There is, however, currently no systematic method used universally for determining the sampling period of the digital control system. Generally, a traditional way to select the sampling frequency is to use 20 to 30 times the bandwidth of the analog control system which has the same system configuration and parameters as the digital one. In this paper, a new method to select the sampling period is suggested which takes into account of the performance as well as the stability of the digital control system. By use of the Irving's model steam generator, the optimal sampling period of an assumptive digital control system for steam generator level control is estimated and is actually verified in the digital control simulation system for Kori-2 nuclear power plant steam generator level control. Consequently, we conclude the optimal sampling period of the digital control system for Kori-2 nuclear power plant steam generator level control is 1 second for all power ranges. 7 figs., 3 tabs., 8 refs. (Author)

  1. Survey of elemental concentrations in lichen samples collected from Sao Paulo State

    International Nuclear Information System (INIS)

    Saiki, M.; Horimoto, L.K.; Vasconcellos, M.B.A.; Coccaro, D.M.B.; Marcelli, M.P.

    2001-01-01

    Samples of the lichen Canoparmelia texana collected in seven different sites of Sao Paulo State and one site of the Parana State were analysed by neutron activation analysis in order to obtain information on the air quality in these regions and also to select a region of interest for the evaluation of baseline level of elements in lichen species. Concentrations of the elements Al, As, Br, Ca, Cd, Cl, Co, Cs, Fe, Hf, K, Mg, Mn, Na, Rb, Sb, Sc, Se, Ti, Th, U, V, Zn and lanthanides were determined and a preliminary comparisons was made between the results obtained for samples collected in different sites. (author)

  2. Acceptability of self-collection sampling for HPV-DNA testing in low-resource settings: a mixed methods approach.

    Science.gov (United States)

    Bansil, Pooja; Wittet, Scott; Lim, Jeanette L; Winkler, Jennifer L; Paul, Proma; Jeronimo, Jose

    2014-06-12

    Vaginal self-sampling with HPV-DNA tests is a promising primary screening method for cervical cancer. However, women's experiences, concerns and the acceptability of such tests in low-resource settings remain unknown. In India, Nicaragua, and Uganda, a mixed-method design was used to collect data from surveys (N = 3,863), qualitative interviews (N = 72; 20 providers and 52 women) and focus groups (N = 30 women) on women's and providers' experiences with self-sampling, women's opinions of sampling at home, and their future needs. Among surveyed women, 90% provided a self- collected sample. Of these, 75% reported it was easy, although 52% were initially concerned about hurting themselves and 24% were worried about not getting a good sample. Most surveyed women preferred self-sampling (78%). However it was not clear if they responded to the privacy of self-sampling or the convenience of avoiding a pelvic examination, or both. In follow-up interviews, most women reported that they didn't mind self-sampling, but many preferred to have a provider collect the vaginal sample. Most women also preferred clinic-based screening (as opposed to home-based self-sampling), because the sample could be collected by a provider, women could receive treatment if needed, and the clinic was sanitary and provided privacy. Self-sampling acceptability was higher when providers prepared women through education, allowed women to examine the collection brush, and were present during the self-collection process. Among survey respondents, aids that would facilitate self-sampling in the future were: staff help (53%), additional images in the illustrated instructions (31%), and a chance to practice beforehand with a doll/model (26%). Self-and vaginal-sampling are widely acceptable among women in low-resource settings. Providers have a unique opportunity to educate and prepare women for self-sampling and be flexible in accommodating women's preference for self-sampling.

  3. Evaluation of a new simple collection device for sampling of microparticles in exhaled breath.

    Science.gov (United States)

    Seferaj, Sabina; Ullah, Shahid; Tinglev, Åsa; Carlsson, Sten; Winberg, Jesper; Stambeck, Peter; Beck, Olof

    2018-03-12

    The microparticle fraction of exhaled breath is of interest for developing clinical biomarkers. Exhaled particles may contain non-volatile components from all parts of the airway system, formed during normal breathing. This study aimed to evaluate a new, simple sampling device, based on impaction, for collecting microparticles from exhaled breath. Performance of the new device was compared with that of the existing SensAbues membrane filter device. The analytical work used liquid chromatography-tandem mass spectrometry methods. The new device collected three subsamples and these were separately analysed from eight individuals. No difference was observed between the centre position (0.91 ng/sample) and the side positions (1.01 ng/sample) using major phosphatidylcholine (PC) 16:0/16:0 as the analyte. Exhaled breath was collected from eight patients on methadone maintenance treatment. The intra-individual variability in measured methadone concentration between the three collectors was 8.7%. In another experiment using patients on methadone maintenance treatment, the sampling efficiency was compared with an established filter device. Compared to the existing device, the efficiency of the new device was 121% greater for methadone and 1450% greater for DPPC. The data from lipid analysis also indicated that a larger fraction of the collected material was from the distal parts. Finally, a study using an optical particle counter indicated that the device preferentially collects the larger particle fraction. In conclusion, this study demonstrates the usefulness of the new device for collecting non-volatile components from exhaled breath. The performance of the device was superior to the filter device in several aspects.

  4. [Establishment and Management of Multicentral Collection Bio-sample Banks of Malignant Tumors from Digestive System].

    Science.gov (United States)

    Shen, Si; Shen, Junwei; Zhu, Liang; Wu, Chaoqun; Li, Dongliang; Yu, Hongyu; Qiu, Yuanyuan; Zhou, Yi

    2015-11-01

    To establish and manage of multicentral collection bio-sample banks of malignant tumors from digestive system, the paper designed a multicentral management system, established the standard operation procedures (SOPs) and leaded ten hospitals nationwide to collect tumor samples. The biobank has been established for half a year, and has collected 695 samples from patients with digestive system malignant tumor. The clinical data is full and complete, labeled in a unified way and classified to be managed. The clinical and molecular biology researches were based on the biobank, and obtained achievements. The biobank provides a research platform for malignant tumor of digestive system from different regions and of different types.

  5. Sample collection and preparation of biofluids and extracts for gas chromatography-mass spectrometry.

    Science.gov (United States)

    Emwas, Abdul-Hamid M; Al-Talla, Zeyad A; Kharbatia, Najeh M

    2015-01-01

    To maximize the utility of gas chromatography-mass spectrometry (GC-MS) in metabonomics research, all stages of the experimental design should be standardized, including sample collection, storage, preparation, and sample separation. Moreover, the prerequisite for any GC-MS analysis is that a compound must be volatile and thermally stable if it is to be analyzed using this technique. Since many metabolites are nonvolatile and polar in nature, they are not readily amenable to analysis by GC-MS and require initial chemical derivatization of the polar functional groups in order to reduce the polarity and to increase the thermal stability and volatility of the analytes. In this chapter, an overview is presented of the optimum approach to sample collection, storage, and preparation for gas chromatography-mass spectrometry-based metabonomics with particular focus on urine samples as example of biofluids.

  6. Effects of Storage and Type of Blood Collection Tubes on Hepatitis C Virus Level in Whole Blood Samples

    Science.gov (United States)

    Kessler, Harald H.; Stelzl, Evelyn; Raggam, Reinhard B.; Haas, Josef; Kirchmeir, Franz; Hegenbarth, Karin; Daghofer, Elisabeth; Santner, Brigitte I.; Marth, Egon; Stauber, Rudolf E.

    2001-01-01

    In this study, we compared serum hepatitis C virus (HCV) RNA concentrations with HCV RNA concentrations in whole blood collection tubes, including two different types of EDTA tubes and nucleic acid stabilization tubes (NASTs). We also investigated the impact of a processing delay on HCV RNA concentration in these tubes. In NASTs, the mean HCV RNA concentration was comparable to the mean serum HCV RNA concentration at “date zero.” In EDTA tubes, mean baseline HCV RNA concentrations were higher. Storage at room temperature up to 96 h did not result in a decline of HCV RNA concentration in any of the whole blood collection tubes. In NASTs, HCV RNA concentrations remained stable during the whole study period, whereas a significant increase of HCV RNA was observed in both types of EDTA tubes at 96 h compared to date zero. We concluded that HCV RNA remains stable in NASTs at room temperature for at least 96 h, allowing greater flexibility in sample collection and transport. PMID:11325991

  7. Performance of a hydrostatic sampler for collecting samples at the water-sediment interface in lakes

    Directory of Open Access Journals (Sweden)

    Fernando PEDROZO

    2008-02-01

    Full Text Available The water-sediment interface plays a significant role in the determination of the trophic degree of a waterbody. Numerous redox reactions take place there, resulting in the release of contaminants from the sediments to the water column. The aim of the present work was to develop an equipment for collecting samples from the water-sediment interface. Such equipment was to have a simple design, low construction cost, no depth limitations, and high levels of personal safety and to be reliable in the collection of samples. The performance of the hydrostatic sampler thus developed was tested against samples collected either remotely with a corer or directly with syringes by autonomous divers. The hydrostatic sampler permits access to depths where the costs of the traditional diving methodology are expensive, and where working conditions are dangerous for the diver. The hydrostatic sampler provides an additional means of collecting samples from the water-sediment interface, which together with pore-water samples, facilitates the investigation and understanding of chemical mechanisms in lakes, for instance, those that control the P release from sediment to the water column.

  8. Archival policies and collections database for the Woods Hole Science Center's marine sediment samples

    Science.gov (United States)

    Buczkowski, Brian J.; Kelsey, Sarah A.

    2007-01-01

    The Woods Hole Science Center of the U.S. Geological Survey (USGS) has been an active member of the Woods Hole research community, Woods Hole, Massachusetts, for over 40 years. In that time there have been many projects that involved the collection of sediment samples conducted by USGS scientists and technicians for the research and study of seabed environments and processes. These samples were collected at sea or near shore and then brought back to the Woods Hole Science Center (WHSC) for analysis. While at the center, samples are stored in ambient temperature, refrigerated and freezing conditions ranging from +2º Celsius to -18º Celsius, depending on the best mode of preparation for the study being conducted or the duration of storage planned for the samples. Recently, storage methods and available storage space have become a major concern at the WHSC. The core and sediment archive program described herein has been initiated to set standards for the management, methods, and duration of sample storage. A need has arisen to maintain organizational consistency and define storage protocol. This handbook serves as a reference and guide to all parties interested in using and accessing the WHSC's sample archive and also defines all the steps necessary to construct and maintain an organized collection of geological samples. It answers many questions as to the way in which the archive functions.

  9. JSC Advanced Curation: Research and Development for Current Collections and Future Sample Return Mission Demands

    Science.gov (United States)

    Fries, M. D.; Allen, C. C.; Calaway, M. J.; Evans, C. A.; Stansbery, E. K.

    2015-01-01

    Curation of NASA's astromaterials sample collections is a demanding and evolving activity that supports valuable science from NASA missions for generations, long after the samples are returned to Earth. For example, NASA continues to loan hundreds of Apollo program samples to investigators every year and those samples are often analyzed using instruments that did not exist at the time of the Apollo missions themselves. The samples are curated in a manner that minimizes overall contamination, enabling clean, new high-sensitivity measurements and new science results over 40 years after their return to Earth. As our exploration of the Solar System progresses, upcoming and future NASA sample return missions will return new samples with stringent contamination control, sample environmental control, and Planetary Protection requirements. Therefore, an essential element of a healthy astromaterials curation program is a research and development (R&D) effort that characterizes and employs new technologies to maintain current collections and enable new missions - an Advanced Curation effort. JSC's Astromaterials Acquisition & Curation Office is continually performing Advanced Curation research, identifying and defining knowledge gaps about research, development, and validation/verification topics that are critical to support current and future NASA astromaterials sample collections. The following are highlighted knowledge gaps and research opportunities.

  10. Integrated sampling vs ion chromatography: Mathematical considerations

    International Nuclear Information System (INIS)

    Sundberg, L.L.

    1992-01-01

    This paper presents some general purpose considerations that can be utilized when comparisons are made between the results of integrated sampling over several hours or days, and ion chromatography where sample collection times are measured in minutes. The discussion is geared toward the measurement of soluble transition metal ions in BWR feedwater. Under steady-state conditions, the concentrations reported by both techniques should be in reasonable agreement. Transient operations effect both types of measurements. A simplistic model, applicable to both sampling techniques, is presented that demonstrates the effect of transients which occur during the acquisition of a steady-state sample. For a common set of conditions, the integrated concentration is proportional to the concentration and duration of the transient, and inversely proportional to the sample collection time. The adjustment of the collection period during a known transient allows an estimation of peak transient concentration. Though the probability of sampling a random transient with the integrated sampling technique is very high, the magnitude is severely diluted with long integration times. Transient concentrations are magnified with ion chromatography, but the probability of sampling a transient is significantly lower using normal ion chromatography operations. Various data averaging techniques are discussed for integrated sampling and IC determinations. The use of time-weighted averages appears to offer more advantages over arithmetic and geometric means for integrated sampling when the collection period is variable. For replicate steady-state ion chromatography determinations which bracket a transient sample, it may be advantageous to ignore the calculation of averages, and report the data as trending information only

  11. Validation of Marek's disease diagnosis and monitoring of Marek's disease vaccines from samples collected in FTA cards.

    Science.gov (United States)

    Cortes, Aneg L; Montiel, Enrique R; Gimeno, Isabel M

    2009-12-01

    The use of Flinders Technology Associates (FTA) filter cards to quantify Marek's disease virus (MDV) DNA for the diagnosis of Marek's disease (MD) and to monitor MD vaccines was evaluated. Samples of blood (43), solid tumors (14), and feather pulp (FP; 36) collected fresh and in FTA cards were analyzed. MDV DNA load was quantified by real-time PCR. Threshold cycle (Ct) ratios were calculated for each sample by dividing the Ct value of the internal control gene (glyceraldehyde-3-phosphate dehydrogenase) by the Ct value of the MDV gene. Statistically significant correlation (P FTA cards by using Pearson's correlation test. Load of serotype 1 MDV DNA was quantified in 24 FP, 14 solid tumor, and 43 blood samples. There was a statistically significant correlation between FP (r = 0.95), solid tumor (r = 0.94), and blood (r = 0.9) samples collected fresh and in FTA cards. Load of serotype 2 MDV DNA was quantified in 17 FP samples, and the correlation between samples collected fresh and in FTA cards was also statistically significant (Pearson's coefficient, r = 0.96); load of serotype 3 MDV DNA was quantified in 36 FP samples, and correlation between samples taken fresh and in FTA cards was also statistically significant (r = 0.84). MDV DNA samples extracted 3 days (t0) and 8 months after collection (t1) were used to evaluate the stability of MDV DNA in archived samples collected in FTA cards. A statistically significant correlation was found for serotype 1 (r = 0.96), serotype 2 (r = 1), and serotype 3 (r = 0.9). The results show that FTA cards are an excellent media to collect, transport, and archive samples for MD diagnosis and to monitor MD vaccines. In addition, FTA cards are widely available, inexpensive, and adequate for the shipment of samples nationally and internationally.

  12. Impact of collection container material and holding times on sample integrity for mercury and methylmercury in water

    Energy Technology Data Exchange (ETDEWEB)

    Riscassi, Ami L [ORNL; Miller, Carrie L [ORNL; Brooks, Scott C [ORNL

    2014-01-01

    Mercury (Hg) and methylmercury (MeHg) concentrations in streamwater can vary on short timescales (hourly or less) during storm flow and on a diel cycle; the frequency and timing of sampling required to accurately characterize these dynamics may be difficult to accomplish manually. Automated sampling can assist in sample collection; however use has been limited for Hg and MeHg analysis due to stability concerns of trace concentrations during extended storage times. We examined the viability of using automated samplers with disposable low-density polyethylene (LDPE) sample bags to collect industrially contaminated streamwater for unfiltered and filtered Hg and MeHg analysis. Specifically we investigated the effect of holding times ranging from hours to days on streamwater collected during baseflow and storm flow. Unfiltered and filtered Hg and MeHg concentrations decreased with increases in time prior to sample processing; holding times of 24 hours or less resulted in concentration changes (mean 11 7% different) similar to variability in duplicates collected manually during analogous field conditions (mean 7 10% different). Comparisons of samples collected with manual and automated techniques throughout a year for a wide range of stream conditions were also found to be similar to differences observed between duplicate grab samples. These results demonstrate automated sampling into LDPE bags with holding times of 24 hours or less can be effectively used to collect streamwater for Hg and MeHg analysis, and encourage the testing of these materials and methods for implementation in other aqueous systems where high-frequency sampling is warranted.

  13. 78 FR 79009 - Proposed Information Collection; Radiation Sampling and Exposure Records (Pertains to Underground...

    Science.gov (United States)

    2013-12-27

    ... soliciting comments concerning the proposed information collection for updating Radiation Sampling and... exposed with no adverse effects have been established and are expressed as working levels (WL). The... mandatory samplings. Records must include the sample date, location, and results, and must be retained at...

  14. Comparison of semen parameters in samples collected by masturbation at a clinic and at home.

    Science.gov (United States)

    Elzanaty, Saad; Malm, Johan

    2008-06-01

    To investigate differences in semen quality between samples collected by masturbation at a clinic and at home. Cross-sectional study. Fertility center. Three hundred seventy-nine men assessed for infertility. None. Semen was analyzed according to World Health Organization guidelines. Seminal markers of epididymal (neutral alpha-glucosidase), prostatic (prostate-specific antigen and zinc), and seminal vesicle (fructose) function were measured. Two patient groups were defined according to sample collection location: at a clinic (n = 273) or at home (n = 106). Compared with clinic-collected semen, home-collected samples had statistically significantly higher values for sperm concentration, total sperm count, rapid progressive motility, and total count of progressive motility. Semen volume, proportion of normal sperm morphology, neutral alpha-glucosidase, prostate-specific antigen, zinc, and fructose did not differ significantly between groups. An abnormal sperm concentration (masturbation at home compared with at a clinic. This should be taken into consideration in infertility investigations.

  15. Survey research with a random digit dial national mobile phone sample in Ghana: Methods and sample quality

    Science.gov (United States)

    Sefa, Eunice; Adimazoya, Edward Akolgo; Yartey, Emmanuel; Lenzi, Rachel; Tarpo, Cindy; Heward-Mills, Nii Lante; Lew, Katherine; Ampeh, Yvonne

    2018-01-01

    Introduction Generating a nationally representative sample in low and middle income countries typically requires resource-intensive household level sampling with door-to-door data collection. High mobile phone penetration rates in developing countries provide new opportunities for alternative sampling and data collection methods, but there is limited information about response rates and sample biases in coverage and nonresponse using these methods. We utilized data from an interactive voice response, random-digit dial, national mobile phone survey in Ghana to calculate standardized response rates and assess representativeness of the obtained sample. Materials and methods The survey methodology was piloted in two rounds of data collection. The final survey included 18 demographic, media exposure, and health behavior questions. Call outcomes and response rates were calculated according to the American Association of Public Opinion Research guidelines. Sample characteristics, productivity, and costs per interview were calculated. Representativeness was assessed by comparing data to the Ghana Demographic and Health Survey and the National Population and Housing Census. Results The survey was fielded during a 27-day period in February-March 2017. There were 9,469 completed interviews and 3,547 partial interviews. Response, cooperation, refusal, and contact rates were 31%, 81%, 7%, and 39% respectively. Twenty-three calls were dialed to produce an eligible contact: nonresponse was substantial due to the automated calling system and dialing of many unassigned or non-working numbers. Younger, urban, better educated, and male respondents were overrepresented in the sample. Conclusions The innovative mobile phone data collection methodology yielded a large sample in a relatively short period. Response rates were comparable to other surveys, although substantial coverage bias resulted from fewer women, rural, and older residents completing the mobile phone survey in

  16. Survey research with a random digit dial national mobile phone sample in Ghana: Methods and sample quality.

    Science.gov (United States)

    L'Engle, Kelly; Sefa, Eunice; Adimazoya, Edward Akolgo; Yartey, Emmanuel; Lenzi, Rachel; Tarpo, Cindy; Heward-Mills, Nii Lante; Lew, Katherine; Ampeh, Yvonne

    2018-01-01

    Generating a nationally representative sample in low and middle income countries typically requires resource-intensive household level sampling with door-to-door data collection. High mobile phone penetration rates in developing countries provide new opportunities for alternative sampling and data collection methods, but there is limited information about response rates and sample biases in coverage and nonresponse using these methods. We utilized data from an interactive voice response, random-digit dial, national mobile phone survey in Ghana to calculate standardized response rates and assess representativeness of the obtained sample. The survey methodology was piloted in two rounds of data collection. The final survey included 18 demographic, media exposure, and health behavior questions. Call outcomes and response rates were calculated according to the American Association of Public Opinion Research guidelines. Sample characteristics, productivity, and costs per interview were calculated. Representativeness was assessed by comparing data to the Ghana Demographic and Health Survey and the National Population and Housing Census. The survey was fielded during a 27-day period in February-March 2017. There were 9,469 completed interviews and 3,547 partial interviews. Response, cooperation, refusal, and contact rates were 31%, 81%, 7%, and 39% respectively. Twenty-three calls were dialed to produce an eligible contact: nonresponse was substantial due to the automated calling system and dialing of many unassigned or non-working numbers. Younger, urban, better educated, and male respondents were overrepresented in the sample. The innovative mobile phone data collection methodology yielded a large sample in a relatively short period. Response rates were comparable to other surveys, although substantial coverage bias resulted from fewer women, rural, and older residents completing the mobile phone survey in comparison to household surveys. Random digit dialing of mobile

  17. Survey research with a random digit dial national mobile phone sample in Ghana: Methods and sample quality.

    Directory of Open Access Journals (Sweden)

    Kelly L'Engle

    Full Text Available Generating a nationally representative sample in low and middle income countries typically requires resource-intensive household level sampling with door-to-door data collection. High mobile phone penetration rates in developing countries provide new opportunities for alternative sampling and data collection methods, but there is limited information about response rates and sample biases in coverage and nonresponse using these methods. We utilized data from an interactive voice response, random-digit dial, national mobile phone survey in Ghana to calculate standardized response rates and assess representativeness of the obtained sample.The survey methodology was piloted in two rounds of data collection. The final survey included 18 demographic, media exposure, and health behavior questions. Call outcomes and response rates were calculated according to the American Association of Public Opinion Research guidelines. Sample characteristics, productivity, and costs per interview were calculated. Representativeness was assessed by comparing data to the Ghana Demographic and Health Survey and the National Population and Housing Census.The survey was fielded during a 27-day period in February-March 2017. There were 9,469 completed interviews and 3,547 partial interviews. Response, cooperation, refusal, and contact rates were 31%, 81%, 7%, and 39% respectively. Twenty-three calls were dialed to produce an eligible contact: nonresponse was substantial due to the automated calling system and dialing of many unassigned or non-working numbers. Younger, urban, better educated, and male respondents were overrepresented in the sample.The innovative mobile phone data collection methodology yielded a large sample in a relatively short period. Response rates were comparable to other surveys, although substantial coverage bias resulted from fewer women, rural, and older residents completing the mobile phone survey in comparison to household surveys. Random digit

  18. Mapping of marine benthic invertebrates in the Oslofjord and the Skagerrak: sampling data of museum collections from 1950-1955 and from recent investigations

    Directory of Open Access Journals (Sweden)

    Eivind Oug

    2015-12-01

    Full Text Available Data from large sampling programmes for the mapping of marine invertebrates in the Oslofjord, Norway, and the Skagerrak, spanning more than six decades, are compiled and digitized to provide easy access in modern data repositories. Two sampling programmes undertaken in the period 1950–55 are still the most extensive mapping of marine benthic fauna in the area. Information from a total of more than 900 localities, or sampling events, covering all benthic habitats in the Oslofjord and coastal waters to Kvitsøy in Rogaland county, have been carefully digitized from field notes, original sea charts, and primary observations from sample handling in the field. Geographical coordinates referred to WGS84 chart datum have been fixed with a general accuracy of 20 m in the Oslofjord and 100–250 m in coastal areas, based on precise map sketches with cross-bearings to land objects and chart annotations. Most samples were collected using triangular, Agassiz and lightweight dredges. The collected material has been deposited in the collections of the Natural History Museum, University of Oslo. Two recent projects, ‘Polyskag’ and ‘Bioskag’ (2006–2014, are briefly described. The projects focused on the diversity of marine bristle worms (Polychaeta, inter alia providing material for molecular genetic analyses. Type localities for early described species and generally understudied biotopes were visited. The data from the 1950s, together with recent studies, constitute a considerable resource for studies of biodiversity, facilitated through the sharing of species records from the museum collections in modern data repositories. The accurate positioning of sampling localities in the 1950s is of particular value for documenting species distributions over long time spans, thus providing a reference base for studying present and future species changes and assessing the effects of human influence and environmental changes in the Oslofjord and the Skagerrak.

  19. Use of self-collected capillary blood samples for islet autoantibody screening in relatives: a feasibility and acceptability study.

    Science.gov (United States)

    Liu, Y; Rafkin, L E; Matheson, D; Henderson, C; Boulware, D; Besser, R E J; Ferrara, C; Yu, L; Steck, A K; Bingley, P J

    2017-07-01

    To evaluate the feasibility of using self-collected capillary blood samples for islet autoantibody testing to identify risk in relatives of people with Type 1 diabetes. Participants were recruited via the observational TrialNet Pathway to Prevention study, which screens and monitors relatives of people with Type 1 diabetes for islet autoantibodies. Relatives were sent kits for capillary blood collection, with written instructions, an online instructional video link and a questionnaire. Sera from capillary blood samples were tested for autoantibodies to glutamic acid decarboxylase, islet antigen-2, insulin and zinc transporter 8. 'Successful' sample collection was defined as obtaining sufficient volume and quality to provide definitive autoantibody results, including confirmation of positive results by repeat assay. In 240 relatives who returned samples, the median (range) age was 15.5 (1-49) years and 51% were male. Of these samples, 98% were sufficient for glutamic acid decarboxylase, islet antigen-2 and zinc transporter 8 autoantibody testing and 84% for insulin autoantibody testing and complete autoantibody screen. The upper 90% confidence bound for unsuccessful collection was 4.4% for glutamic acid decarboxylase, islet antigen-2 and/or zinc transporter 8 autoantibody assays, and 19.3% for insulin autoantibodies. Despite 43% of 220 questionnaire respondents finding capillary blood collection uncomfortable or painful, 82% preferred home self-collection of capillary blood samples compared with outpatient venepuncture (90% of those aged 18 years). The perceived difficulty of collecting capillary blood samples did not affect success rate. Self-collected capillary blood sampling offers a feasible alternative to venous sampling, with the potential to facilitate autoantibody screening for Type 1 diabetes risk. © 2017 Diabetes UK.

  20. New Zealand guidelines for the collection of groundwater samples for chemical and isotopic analyses

    International Nuclear Information System (INIS)

    Rosen, M.R.; Cameron, S.G.; Reeves, R.R.; Taylor, C.B.

    1999-01-01

    Chemical and isotopic analyses of groundwater are important tools for differentiating between the natural composition and human-induced contaminants of groundwater. A comprehensive suite of inorganic water chemical analyses is necessary to characterise waters. The geology of New Zealand is diverse, so it is impractical to characterise a ''typical'' groundwater chemical composition. Each aquifer system should be evaluated individually because the major dissolved species contain useful information about the pathways of water through the soil zone into the aquifer. Analyses of major ions such as chloride, nitrate, potassium and sulphate often give indication of septic systems and agricultural contamination. The minor ions, while most are not considered contaminants, are often indicators of human activity. Iron and manganese are good indicators of Eh potential, which is an important control on the mobility of many heavy metals. The inexpensive inorganic chemical analytical suite should be used as a guide to advisability of more expensive contaminant testing. The purpose of this manual is to provide consistent groundwater sampling guidelines for use throughout New Zealand. Sinton's (1998) guide to groundwater sampling techniques provided a sound basis for the accurate collection of groundwater samples. However Sinton did not address sampling materials and techniques for the collection of samples for ultra trace component analysis or the collection of environmental isotope samples. These important aspects of groundwater sampling have been included in this updated manual. (author). 30 refs., 12 figs., 5 tabs., 1 appendix

  1. Analysis of Samples Collected from the Surface of Interim Storage Canisters at Calvert Cliffs in June 2017: Revision 01.

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Charles R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schindelholz, Eric John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-11-01

    In June 2017, dust and salt samples were collected from the surface of Spent Nuclear Fuel (SNF) dry storage canisters at the Calvert Cliffs Nuclear Power Plant. The samples were delivered to Sandia National laboratories for analysis. Two types of samples were collected: filter-backed Scotch-Brite TM pads were used to collect dry dust samples for characterization of salt and dust morphologies and distributions; and Saltsmart TM test strips were used to collect soluble salts for determining salt surface loadings per unit area. After collection, the samples were sealed into plastic sleeves for shipping. Condensation within the sleeves containing the Scotch-Brite TM samples remobilized the salts, rendering them ineffective for the intended purpose, and also led to mold growth, further compromising the samples; for these reasons, the samples were not analyzed. The SaltSmart TM samples were unaffected and were analyzed by ion chromatography for major anions and cations. The results of those analyses are presented here.

  2. Collection and preparation of marine samples for radionuclide analysis

    International Nuclear Information System (INIS)

    Holm, E.

    1997-01-01

    The ultimate goal of research in radioecology is to be able to predict the pathways of radioactive material in the environment and hence estimate possible doses to the population in various regions. Knowledge of levels of contamination are necessary to maintain control of operations of nuclear facilities. Correct methods of sample collection, handling and preparation are among the most important parts for a correct assessment. On basis of the final results of radionuclide concentrations, scientific, medical and political decisions are taken. (author)

  3. A simple and novel method for retrieval of Pasteurellaceae from swab samples collected in the field

    DEFF Research Database (Denmark)

    Hansen, Mie J; Bertelsen, Mads F; Dietz, Rune

    2013-01-01

    and stored at -20°C. As a control study, 15 samples were collected from the oral cavity of a captive brown bear. One was immediately plated, while the remaining 12 swabs were stored at -20°C for 7 days and multiples of 30 days up to 330 days prior to plating. Two samples were stored without the medium for 7......Traditionally it has been difficult or impossible to collect and preserve bacterial samples of especially fastidious bacteria in mixed primary cultures, unless the samples could be transported to a laboratory within approximately 24 h. Therefore, a simple novel method for preserving swab samples...... until bacterial isolation can be completed in the laboratory was developed and evaluated. Pasteurellaceae bacteria were used as a representative for fastidious bacteria. A 7.5% glucose serum medium was used as freeze medium. Swab samples were soaked in the medium a maximum of 2 h after collection...

  4. Procedures for the collection and preservation of groundwater and surface water samples and for the installation of monitoring wells

    International Nuclear Information System (INIS)

    Korte, N.; Kearl, P.

    1984-01-01

    Proper sampling procedures are essential for a successful water-quality monitoring program. It must be emphasized, however, that it is impossible to maintain absolutely in-situ conditions when collecting and preserving a water sample, whether from a flowing stream or an aquifer. Consequently, the most that can reasonably be expected is to collect a best possible sample with minimal disturbance. This document describes procedures for installing monitoring wells and for collecting samples of surface water and groundwater. The discussion of monitoring wells includes mention of multilevel sampling and a general overview of vadose-zone monitoring. Guidelines for well installation are presented in detail. The discussion of water-sample collection contains evaluations of sampling pumps, filtration equipment, and sample containers. Sample-preservation techniques, as published by several government and private sources, are reviewed. Finally, step-by-step procedures for collection of water samples are provided; these procedures address such considerations as necessary equipment, field operations, and written documentation. Separate procedures are also included for the collection of samples for determination of sulfide and for reactive aluminum. The report concludes with a brief discussion of adverse sampling, conditions that may significantly affect the quality of the data. Appendix A presents a rationale for the development and use of statistical considerations in water sampling to ensure a more complete water quality monitoring program. 51 references, 9 figures, 4 tables

  5. Polycyclic aromatic hydrocarbons in air samples of meat smokehouses

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Olsen, I L; Poulsen, O M

    1992-01-01

    In a screening programme nine Danish meat smokehouses were randomly selected for measurements on concentration of airborne polycyclic aromatic hydrocarbons (PAH). A total of 23 stationary air samples were collected during the entire working period of the kiln either above the kiln doors or approx......In a screening programme nine Danish meat smokehouses were randomly selected for measurements on concentration of airborne polycyclic aromatic hydrocarbons (PAH). A total of 23 stationary air samples were collected during the entire working period of the kiln either above the kiln doors...

  6. Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure using a laser sensor

    Science.gov (United States)

    Van Berkel, Gary J [Clinton, TN; Kertesz, Vilmos [Knoxville, TN

    2012-02-21

    A system and method utilizes distance-measuring equipment including a laser sensor for controlling the collection instrument-to-surface distance during a sample collection process for use, for example, with mass spectrometric detection. The laser sensor is arranged in a fixed positional relationship with the collection instrument, and a signal is generated by way of the laser sensor which corresponds to the actual distance between the laser sensor and the surface. The actual distance between the laser sensor and the surface is compared to a target distance between the laser sensor and the surface when the collection instrument is arranged at a desired distance from the surface for sample collecting purposes, and adjustments are made, if necessary, so that the actual distance approaches the target distance.

  7. Acceptability of self-collected vaginal samples for HPV testing in an ...

    African Journals Online (AJOL)

    Objective: To evaluate the acceptability of self-collected vaginal samples for HPV testing in women living in rural and urban areas of Madagascar. Materials and methods: Participants were recruited in a health care center (urban group) and smaller affiliated dispensaries (rural group). They were invited to perform ...

  8. Reliability of Serum Metabolites over a Two-Year Period: A Targeted Metabolomic Approach in Fasting and Non-Fasting Samples from EPIC

    Science.gov (United States)

    Achaintre, David; Sacerdote, Carlotta; Vineis, Paolo; Key, Timothy J.; Onland Moret, N. Charlotte; Scalbert, Augustin; Rinaldi, Sabina; Ferrari, Pietro

    2015-01-01

    Objective Although metabolic profiles have been associated with chronic disease risk, lack of temporal stability of metabolite levels could limit their use in epidemiological investigations. The present study aims to evaluate the reliability over a two-year period of 158 metabolites and compare reliability over time in fasting and non-fasting serum samples. Methods Metabolites were measured with the AbsolueIDQp180 kit (Biocrates, Innsbruck, Austria) by mass spectrometry and included acylcarnitines, amino acids, biogenic amines, hexoses, phosphatidylcholines and sphingomyelins. Measurements were performed on repeat serum samples collected two years apart in 27 fasting men from Turin, Italy, and 39 non-fasting women from Utrecht, The Netherlands, all participating in the European Prospective Investigation into Cancer and Nutrition (EPIC) study. Reproducibility was assessed by estimating intraclass correlation coefficients (ICCs) in multivariable mixed models. Results In fasting samples, a median ICC of 0.70 was observed. ICC values were fasting samples, the median ICC was 0.54. ICC values were fasting as compared to fasting samples, with a statistically significant difference for 19–36% of acylcarnitines, phosphatidylcholines and sphingomyelins. Conclusion A single measurement per individual may be sufficient for the study of 73% and 52% of the metabolites showing ICCs >0.50 in fasting and non-fasting samples, respectively. ICCs were higher in fasting samples that are preferable to non-fasting. PMID:26274920

  9. An Interdisciplinary Method for the Visualization of Novel High-Resolution Precision Photography and Micro-XCT Data Sets of NASA's Apollo Lunar Samples and Antarctic Meteorite Samples to Create Combined Research-Grade 3D Virtual Samples for the Benefit of Astromaterials Collections Conservation, Curation, Scientific Research and Education

    Science.gov (United States)

    Blumenfeld, E. H.; Evans, C. A.; Oshel, E. R.; Liddle, D. A.; Beaulieu, K.; Zeigler, R. A.; Hanna, R. D.; Ketcham, R. A.

    2016-01-01

    New technologies make possible the advancement of documentation and visualization practices that can enhance conservation and curation protocols for NASA's Astromaterials Collections. With increasing demands for accessibility to updated comprehensive data, and with new sample return missions on the horizon, it is of primary importance to develop new standards for contemporary documentation and visualization methodologies. Our interdisciplinary team has expertise in the fields of heritage conservation practices, professional photography, photogrammetry, imaging science, application engineering, data curation, geoscience, and astromaterials curation. Our objective is to create virtual 3D reconstructions of Apollo Lunar and Antarctic Meteorite samples that are a fusion of two state-of-the-art data sets: the interior view of the sample by collecting Micro-XCT data and the exterior view of the sample by collecting high-resolution precision photography data. These new data provide researchers an information-rich visualization of both compositional and textural information prior to any physical sub-sampling. Since January 2013 we have developed a process that resulted in the successful creation of the first image-based 3D reconstruction of an Apollo Lunar Sample correlated to a 3D reconstruction of the same sample's Micro- XCT data, illustrating that this technique is both operationally possible and functionally beneficial. In May of 2016 we began a 3-year research period during which we aim to produce Virtual Astromaterials Samples for 60 high-priority Apollo Lunar and Antarctic Meteorite samples and serve them on NASA's Astromaterials Acquisition and Curation website. Our research demonstrates that research-grade Virtual Astromaterials Samples are beneficial in preserving for posterity a precise 3D reconstruction of the sample prior to sub-sampling, which greatly improves documentation practices, provides unique and novel visualization of the sample's interior and

  10. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF SOIL SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.20)

    Science.gov (United States)

    This SOP describes the method for collecting soil samples from the child's outdoor play area to measure for persistent organic pollutants. Soil samples are collected by scraping up the top 0.5 cm of soil in a 0.095 m2 (1 ft2) area in the middle of the child's play area.

  11. Chlamydia trachomatis antibody detection in home-collected blood samples for use in epidemiological studies.

    NARCIS (Netherlands)

    Hoenderboom, B M; van Ess, E F; van den Broek, I V F; van Loo, I H M; Hoebe, C J P A; Ouburg, S; Morré, S A

    Capillary blood collected in serum tubes was subjected to centrifugation delay while stored at room temperature. Chlamydia trachomatis (CT) IgG concentrations in aliquoted serum of these blood samples remained stable for seven days after collection. CT IgG concentrations can reliably be measured in

  12. Improved explosive collection and detection with rationally assembled surface sampling materials

    Energy Technology Data Exchange (ETDEWEB)

    Chouyyok, Wilaiwan; Bays, J. Timothy; Gerasimenko, Aleksandr A.; Cinson, Anthony D.; Ewing, Robert G.; Atkinson, David A.; Addleman, R. Shane

    2016-01-01

    Sampling and detection of trace explosives is a key analytical process in modern transportation safety. In this work we have explored some of the fundamental analytical processes for collection and detection of trace level explosive on surfaces with the most widely utilized system, thermal desorption IMS. The performance of the standard muslin swipe material was compared with chemically modified fiberglass cloth. The fiberglass surface was modified to include phenyl functional groups. When compared to standard muslin, the phenyl functionalized fiberglass sampling material showed better analyte release from the sampling material as well as improved response and repeatability from multiple uses of the same swipe. The improved sample release of the functionalized fiberglass swipes resulted in a significant increase in sensitivity. Various physical and chemical properties were systematically explored to determine optimal performance. The results herein have relevance to improving the detection of other explosive compounds and potentially to a wide range of other chemical sampling and field detection challenges.

  13. Sample collection of virulent and non-virulent B. anthracis and Y. pestis for bioforensics analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hong-geller, Elizabeth [Los Alamos National Laboratory; Valdez, Yolanda E [Los Alamos National Laboratory; Shou, Yulin [Los Alamos National Laboratory; Yoshida, Thomas M [Los Alamos National Laboratory; Marrone, Babetta L [Los Alamos National Laboratory; Dunbar, John [Los Alamos National Laboratory

    2009-01-01

    Validated sample collection methods are needed for recovery of microbial evidence in the event of accidental or intentional release of biological agents into the environment. To address this need, we evaluated the sample recovery efficiencies of two collection methods -- swabs and wipes -- for both non-virulent and virulent strains of B. anthracis and Y. pestis from four types of non-porous surfaces: two hydrophilic surfaces, stainless steel and glass, and two hydrophobic surfaces, vinyl and plastic. Sample recovery was quantified using Real-time qPCR to assay for intact DNA signatures. We found no consistent difference in collection efficiency between swabs or wipes. Furthermore, collection efficiency was more surface-dependent for virulent strains than non-virulent strains. For the two non-virulent strains, B. anthracis Sterne and Y. pestis A1122, collection efficiency was approximately 100% and 1 %, respectively, from all four surfaces. In contrast, recovery of B. anthracis Ames spores and Y. pestis C092 from vinyl and plastic was generally lower compared to collection from glass or stainless steel, suggesting that surface hydrophobicity may playa role in the strength of pathogen adhesion. The surface-dependent collection efficiencies observed with the virulent strains may arise from strain-specific expression of capsular material or other cell surface receptors that alter cell adhesion to specific surfaces. These findings contribute to validation of standard bioforensics procedures and emphasize the importance of specific strain and surface interactions in pathogen detection.

  14. Event Processing and Variable Part of Sample Period Determining in Combined Systems Using GA

    Science.gov (United States)

    Strémy, Maximilián; Závacký, Pavol; Jedlička, Martin

    2011-01-01

    This article deals with combined dynamic systems and usage of modern techniques in dealing with these systems, focusing particularly on sampling period design, cyclic processing tasks and related processing algorithms in the combined event management systems using genetic algorithms.

  15. 21 CFR 809.40 - Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs...

    Science.gov (United States)

    2010-04-01

    ... OTC test sample collection systems for drugs of abuse testing. 809.40 Section 809.40 Food and Drugs... Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs of abuse testing. (a) Over-the-counter (OTC) test sample collection systems for drugs of abuse testing (§ 864.3260...

  16. Assessment of selected contaminants in streambed- and suspended-sediment samples collected in Bexar County, Texas, 2007-09

    Science.gov (United States)

    Wilson, Jennifer T.

    2011-01-01

    Elevated concentrations of sediment-associated contaminants are typically associated with urban areas such as San Antonio, Texas, in Bexar County, the seventh most populous city in the United States. This report describes an assessment of selected sediment-associated contaminants in samples collected in Bexar County from sites on the following streams: Medio Creek, Medina River, Elm Creek, Martinez Creek, Chupaderas Creek, Leon Creek, Salado Creek, and San Antonio River. During 2007-09, the U.S. Geological Survey periodically collected surficial streambed-sediment samples during base flow and suspended-sediment (large-volume suspended-sediment) samples from selected streams during stormwater runoff. All sediment samples were analyzed for major and trace elements and for organic compounds including halogenated organic compounds and polycyclic aromatic hydrocarbons (PAHs). Selected contaminants in streambed and suspended sediments in watersheds of the eight major streams in Bexar County were assessed by using a variety of methods—observations of occurrence and distribution, comparison to sediment-quality guidelines and data from previous studies, statistical analyses, and source indicators. Trace elements concentrations were low compared to the consensus-based sediment-quality guidelines threshold effect concentration (TEC) and probable effect concentration (PEC). Trace element concentrations were greater than the TEC in 28 percent of the samples and greater than the PEC in 1.5 percent of the samples. Chromium concentrations exceeded sediment-quality guidelines more frequently than concentrations of any other constituents analyzed in this study (greater than the TEC in 69 percent of samples and greater than the PEC in 8 percent of samples). Mean trace element concentrations generally are lower in Bexar County samples compared to concentrations in samples collected during previous studies in the Austin and Fort Worth, Texas, areas, but considering the relatively

  17. Application of the CometChip platform to assess DNA damage in field-collected blood samples from turtles.

    Science.gov (United States)

    Sykora, Peter; Chiari, Ylenia; Heaton, Andrew; Moreno, Nickolas; Glaberman, Scott; Sobol, Robert W

    2018-05-01

    DNA damage has been linked to genomic instability and the progressive breakdown of cellular and organismal homeostasis, leading to the onset of disease and reduced longevity. Insults to DNA from endogenous sources include base deamination, base hydrolysis, base alkylation, and metabolism-induced oxidative damage that can lead to single-strand and double-strand DNA breaks. Alternatively, exposure to environmental pollutants, radiation or ultra-violet light, can also contribute to exogenously derived DNA damage. We previously validated a novel, high through-put approach to measure levels of DNA damage in cultured mammalian cells. This new CometChip Platform builds on the classical single cell gel electrophoresis or comet methodology used extensively in environmental toxicology and molecular biology. We asked whether the CometChip Platform could be used to measure DNA damage in samples derived from environmental field studies. To this end, we determined that nucleated erythrocytes from multiple species of turtle could be successfully evaluated in the CometChip Platform to quantify levels of DNA damage. In total, we compared levels of DNA damage in 40 animals from two species: the box turtle (Terrapene carolina) and the red-eared slider (Trachemys scripta elegans). Endogenous levels of DNA damage were identical between the two species, yet we did discover some sex-linked differences and changes in DNA damage accumulation. Based on these results, we confirm that the CometChip Platform allows for the measurement of DNA damage in a large number of samples quickly and accurately, and is particularly adaptable to environmental studies using field-collected samples. Environ. Mol. Mutagen. 59:322-333, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  18. Two-point vs multipoint sample collection for the analysis of energy expenditure by use of the doubly labeled water method

    International Nuclear Information System (INIS)

    Welle, S.

    1990-01-01

    Energy expenditure over a 2-wk period was determined by the doubly labeled water (2H2(18)O) method in nine adults. When daily samples were analyzed, energy expenditure was 2859 +/- 453 kcal/d (means +/- SD); when only the first and last time points were considered, the mean calculated energy expenditure was not significantly different (2947 +/- 430 kcal/d). An analysis of theoretical cases in which isotope flux is not constant indicates that the multipoint method can cause errors in the calculation of average isotope fluxes, but these are generally small. Simulations of the effect of analytical error indicate that increasing the number of replicates on two points reduces the impact of technical errors more effectively than does performing single analyses on multiple samples. It appears that generally there is no advantage to collecting frequent samples when the 2H2(18)O method is used to estimate energy expenditure in adult humans

  19. Planning Considerations Related to Collecting and Analyzing Samples of the Martian Soils

    Science.gov (United States)

    Liu, Yang; Mellon, Mike T.; Ming, Douglas W.; Morris, Richard V.; Noble, Sarah K.; Sullivan, Robert J.; Taylor, Lawrence A.; Beaty, David W.

    2014-01-01

    The Mars Sample Return (MSR) End-to-End International Science Analysis Group (E2E-iSAG [1]) established scientific objectives associ-ated with Mars returned-sample science that require the return and investigation of one or more soil samples. Soil is defined here as loose, unconsolidated materials with no implication for the presence or absence of or-ganic components. The proposed Mars 2020 (M-2020) rover is likely to collect and cache soil in addition to rock samples [2], which could be followed by future sample retrieval and return missions. Here we discuss key scientific consid-erations for sampling and caching soil samples on the proposed M-2020 rover, as well as the state in which samples would need to be preserved when received by analysts on Earth. We are seeking feedback on these draft plans as input to mission requirement formulation. A related planning exercise on rocks is reported in an accompanying abstract [3].

  20. Seasonal associations and atmospheric transport distances of fungi in the genus Fusarium collected with unmanned aerial vehicles and ground-based sampling devices

    Science.gov (United States)

    Lin, Binbin; Ross, Shane D.; Prussin, Aaron J.; Schmale, David G.

    2014-09-01

    Spores of fungi in the genus Fusarium may be transported through the atmosphere over long distances. New information is needed to characterize seasonal trends in atmospheric loads of Fusarium and to pinpoint the source(s) of inoculum at both local (farm) and regional (state or country) scales. We hypothesized that (1) atmospheric concentrations of Fusarium spores in an agricultural ecosystem vary with height and season and (2) transport distances from potential inoculum source(s) vary with season. To test these hypotheses, spores of Fusarium were collected from the atmosphere in an agricultural ecosystem in Blacksburg, VA, USA using a Burkard volumetric sampler (BVS) 1 m above ground level and autonomous unmanned aerial vehicles (UAVs) 100 m above ground level. More than 2200 colony forming units (CFUs) of Fusarium were collected during 104 BVS sampling periods and 180 UAV sampling periods over four calendar years (2009-2012). Spore concentrations ranged from 0 to 13 and 0 to 23 spores m-3 for the BVS and the UAVs, respectively. Spore concentrations were generally higher in the fall, spring, and summer, and lower in the winter. Spore concentrations from the BVS were generally higher than those from the UAVs for both seasonal and hourly collections. A Gaussian plume transport model was used to estimate distances to the potential inoculum source(s) by season, and produced mean transport distances of 1.4 km for the spring, 1.7 km for the summer, 1.2 km for the fall, and 4.1 km for the winter. Environmental signatures that predict atmospheric loads of Fusarium could inform disease spread, air pollution, and climate change.

  1. Measuring modulated luminescence using non-modulated stimulation: Ramping the sample period

    DEFF Research Database (Denmark)

    Poolton, N.R.J.; Bøtter-Jensen, L.; Andersen, C.E.

    2003-01-01

    . Directly analogous results to LM-OSL can, however, be achieved with non-modulated excitation sources, by ramping the sample period (RSP) of luminescence detection. RSP-OSL has the distinct advantage over LM-OSL in that, since the excitation remains at full power, data accumulation times (that can...... be considerable) can be reduced by typically 50%. RSP methods are universally applicable and can be employed, for example, where the excitation source is constant heat, rather than light: here, iso-thermal decay of phosphorescence becomes recorded as a sequence of peaks, corresponding to de-trapping of charge...

  2. Geochemical Data for Samples Collected in 2007 Near the Concealed Pebble Porphyry Cu-Au-Mo Deposit, Southwest Alaska

    Science.gov (United States)

    Fey, David L.; Granitto, Matthew; Giles, Stuart A.; Smith, Steven M.; Eppinger, Robert G.; Kelley, Karen D.

    2008-01-01

    relatively subdued topographic relief with an elevation of around 300 m (1000 ft). This portion of Alaska is part of the subarctic regime mountains division, Yukon intermontane plateaus-tayga-meadow province ecoregion, as defined by Bailey (U.S. Forest Service, 2007). Between June 28th and July 12th, 2007, scientists from the USGS collected soil, water, stream sediment, vegetation, heavy-mineral concentrate, till, and rock samples from the deposit area. This report contains analytical results for soil, water, stream sediment, and vegetation samples. Analyses for the heavy-mineral concentrate, till, and rock samples are still in progress. The sampling was undertaken during relatively dry and stable weather conditions. Only minor scattered rain showers occurred during the sampling period, so surface conditions were largely unaffected by weather. The predominant sample media collected were soils and surface waters. Soil and water (mostly from ponds and springs, some from small creeks) samples were collected along a single 7.8 km-long (4.8 mi) east-west traverse across the Pebble East and Pebble West zones and from more distal background areas around Koktuli and Kaskanak Mountains. Sample sites are shown on figure 2 and plate 1, and locality coordinates are provided in the accompanying Access and Excel files named FieldSite. Water samples were analyzed by USGS laboratories with one subset analyzed by Activation Laboratories (Actlabs), as indicated below. Soils and stream sediments were analyzed for their total content by SGS Minerals Services under a contract with the USGS. Soil samples were also leached by selected partial-extraction leaching procedures and then analyzed by several commercial laboratories, as described below. Vegetation samples were analyzed as indicated below.

  3. PIXE Analysis of Atmospheric Aerosol Samples Collected in the Adirondack Mountains

    Science.gov (United States)

    Yoskowitz, Josh; Ali, Salina; Nadareski, Benjamin; Safiq, Alexandrea; Smith, Jeremy; Labrake, Scott; Vineyard, Michael

    2013-10-01

    We have performed an elemental analysis of atmospheric aerosol samples collected at Piseco Lake in Upstate New York using proton induced x-ray emission spectroscopy (PIXE). This work is part of a systematic study of airborne pollution in the Adirondack Mountains. Of particular interest is the sulfur content that can contribute to acid rain, a well-documented problem in the Adirondacks. We used a nine-stage cascade impactor to collect the samples and distribute the particulate matter onto Kapton foils by particle size. The PIXE experiments were performed with 2.2-MeV proton beams from the 1.1-MV pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. X-Ray energy spectra were measured with a silicon drift detector and analyzed with GUPIX software to determine the elemental concentrations of the aerosols. A broad range of elements from silicon to zinc were detected with significant sulfur concentrations measured for particulate matter between 0.25 and 0.5 μm in size. The PIXE analysis will be described and preliminary results will be presented.

  4. Series: Practical guidance to qualitative research. Part 3: Sampling, data collection and analysis.

    Science.gov (United States)

    Moser, Albine; Korstjens, Irene

    2018-12-01

    In the course of our supervisory work over the years, we have noticed that qualitative research tends to evoke a lot of questions and worries, so-called frequently asked questions (FAQs). This series of four articles intends to provide novice researchers with practical guidance for conducting high-quality qualitative research in primary care. By 'novice' we mean Master's students and junior researchers, as well as experienced quantitative researchers who are engaging in qualitative research for the first time. This series addresses their questions and provides researchers, readers, reviewers and editors with references to criteria and tools for judging the quality of qualitative research papers. The second article focused on context, research questions and designs, and referred to publications for further reading. This third article addresses FAQs about sampling, data collection and analysis. The data collection plan needs to be broadly defined and open at first, and become flexible during data collection. Sampling strategies should be chosen in such a way that they yield rich information and are consistent with the methodological approach used. Data saturation determines sample size and will be different for each study. The most commonly used data collection methods are participant observation, face-to-face in-depth interviews and focus group discussions. Analyses in ethnographic, phenomenological, grounded theory, and content analysis studies yield different narrative findings: a detailed description of a culture, the essence of the lived experience, a theory, and a descriptive summary, respectively. The fourth and final article will focus on trustworthiness and publishing qualitative research.

  5. Series: Practical guidance to qualitative research. Part 3: Sampling, data collection and analysis

    Science.gov (United States)

    Moser, Albine; Korstjens, Irene

    2018-01-01

    Abstract In the course of our supervisory work over the years, we have noticed that qualitative research tends to evoke a lot of questions and worries, so-called frequently asked questions (FAQs). This series of four articles intends to provide novice researchers with practical guidance for conducting high-quality qualitative research in primary care. By ‘novice’ we mean Master’s students and junior researchers, as well as experienced quantitative researchers who are engaging in qualitative research for the first time. This series addresses their questions and provides researchers, readers, reviewers and editors with references to criteria and tools for judging the quality of qualitative research papers. The second article focused on context, research questions and designs, and referred to publications for further reading. This third article addresses FAQs about sampling, data collection and analysis. The data collection plan needs to be broadly defined and open at first, and become flexible during data collection. Sampling strategies should be chosen in such a way that they yield rich information and are consistent with the methodological approach used. Data saturation determines sample size and will be different for each study. The most commonly used data collection methods are participant observation, face-to-face in-depth interviews and focus group discussions. Analyses in ethnographic, phenomenological, grounded theory, and content analysis studies yield different narrative findings: a detailed description of a culture, the essence of the lived experience, a theory, and a descriptive summary, respectively. The fourth and final article will focus on trustworthiness and publishing qualitative research. PMID:29199486

  6. Profiling quinones in ambient air samples collected from the Athabasca region (Canada).

    Science.gov (United States)

    Wnorowski, Andrzej; Charland, Jean-Pierre

    2017-12-01

    This paper presents new findings on polycyclic aromatic hydrocarbon oxidation products-quinones that were collected in ambient air samples in the proximity of oil sands exploration. Quinones were characterized for their diurnal concentration variability, phase partitioning, and molecular size distribution. Gas-phase (GP) and particle-phase (PM) ambient air samples were collected separately in the summer; a lower quinone content was observed in the PM samples from continuous 24-h sampling than from combined 12-h sampling (day and night). The daytime/nocturnal samples demonstrated that nighttime conditions led to lower concentrations and some quinones not being detected. The highest quinone levels were associated with wind directions originating from oil sands exploration sites. The statistical correlation with primary pollutants directly emitted from oil sands industrial activities indicated that the bulk of the detected quinones did not originate directly from primary emission sources and that quinone formation paralleled a reduction in primary source NO x levels. This suggests a secondary chemical transformation of primary pollutants as the origin of the determined quinones. Measurements of 19 quinones included five that have not previously been reported in ambient air or in Standard Reference Material 1649a/1649b and seven that have not been previously measured in ambient air in the underivatized form. This is the first paper to report on quinone characterization in secondary organic aerosols originating from oil sands activities, to distinguish chrysenequinone and anthraquinone positional isomers in ambient air, and to report the requirement of daylight conditions for benzo[a]pyrenequinone and naphthacenequinone to be present in ambient air. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  7. Measurement of technetium-99 in soil samples collected in Marshall Islands

    Energy Technology Data Exchange (ETDEWEB)

    Tagami, K.; Uchida, S. [National Inst. of Radiological Sciences, Environmental and Toxicological Sciences Research Group, Chiba (Japan)

    2000-07-01

    Extraction techniques for recovery of technetium-99 ({sup 99}Tc) for ICP-MS measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for {sup 99}Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the {sup 99}Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The {sup 99}Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq/g-dw. The limit of detection for {sup 99}Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq/g-dw under standard operating conditions. (author)

  8. Measurement of technetium-99 in soil samples collected in Marshall Islands

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.

    2000-01-01

    Extraction techniques for recovery of technetium-99 ( 99 Tc) for ICP-MS measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99 Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99 Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99 Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq/g-dw. The limit of detection for 99 Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq/g-dw under standard operating conditions. (author)

  9. Values Education in Ottoman Empire in the Second Constitutional Period: A Sample Lesson

    Science.gov (United States)

    Oruc, Sahin; Ilhan, Genc Osman

    2015-01-01

    Values education holds a significant place in an education environment and many studies are carried out about this new subject area. The aim of this study is to define how the subject of "values education" is handled in a sample lesson designed in the period of Constitution II in the Ottoman Empire. In this study, the lesson plan in the…

  10. 78 FR 36560 - 30-Day Notice of Proposed Information Collection: FHA Lender Approval, Annual Renewal, Periodic...

    Science.gov (United States)

    2013-06-18

    ... 92001-C Non-compliances on Title I Lenders Description of the need for the information and proposed use... Information Collection: FHA Lender Approval, Annual Renewal, Periodic Updates and Noncompliance Reporting by FHA Approved Lenders AGENCY: Office of the Chief Information Officer, HUD. ACTION: Notice. SUMMARY...

  11. Radon exhalation rates from soil and sand samples collected from the vicinity of Yamuna river

    International Nuclear Information System (INIS)

    Garg, A.K.; Sushil Kumar; Chauhan, Pooja; Chauhan, R.P.

    2011-01-01

    Soil, sand and stones are the most popular building materials for Indian dwellings. Radon is released into ambient air from these materials due to ubiquitous uranium and radium in them, thus increasing the airborne radon concentration. The radioactivity in sand and soils is related to radioactivity in the rocks from which they are formed. These materials contain varying amount of uranium. In the present investigation, the radon emanated from soil and sand samples from different locations in the vicinity of Yamuna river has been estimated. The samples have been collected from different locations near the Yamuna river. The samples collecting sites are from Yamunanagar in Haryana to Delhi. The radon concentration in different samples has been calculated, based upon the data, the mass and the surface exhalation rates of radon emanated from them have also been calculated

  12. Mobile sources of polycyclic aromatic hydrocarbons (PAH) and nitro-PAH: Results of samples collected in a roadway tunnel

    International Nuclear Information System (INIS)

    Benner, B.A. Jr.; Gordon, G.E.; Wise, S.A.

    1987-01-01

    A recent review article emphasized the need for further characterizations of the carbonaceous fraction of mobile source emissions, particularly with the impending removal of lead alkyl octane boosters and bromine-containing lead scavengers from regular leaded gasolines. The lead and bromine emitted from the combustion of these fuels have been used as tracers of mobile source emissions for a number of years. Single vehicle emission studies have shed light on the relationship between engine operating parameters and the chemical characteristics of the emissions but they are not suitable for use in source apportionment studies which require emission data from a large number of different vehicles. Air particulate samples collected near a busy highway or in a roadway tunnel would be more appropriate for use in estimating the mobile source contribution of organic compounds to a region. Suspended particle samples collected in a heavily-travelled roadway tunnel (Baltimore Harbor Tunnel, Baltimore, Maryland) were characterized for polycyclic aromatic hydrocarbons (PAH) and some nitro-PAH by gas and liquid chromatographic techniques. These samples included those collected on Teflon filters and on glass fiber filters for investigating any differences in samples collected on an inert (Teflon) and more reactive (glass-fiber) medium. All samples collected on Teflon were backed-up with polyurethane foam plugs (PUF) which trapped any inherent vapor-phase PAH as well as any compounds ''blown-off'' the particles during collection

  13. Quartz analysis in gravimetric sampling

    International Nuclear Information System (INIS)

    Rex, D.A.

    1990-01-01

    An overview of the methods employed in the assessment of quartz exposure is provided. The principles and some of the problems associated with each method is discussed. The methods reviewed include wet chemical methods, X-ray diffraction and infrared absorption of which the latter two methods are deemed appropriate for analysing quartz on personal gravimetric collected samples. The implications of combining area samples collected over a six month period, and performing only a single quartz analysis rather than separate analyses, are considered. Finally, various options open to mines with regard to their involvement with quartz analysis are also briefly discussed. 35 refs., 6 figs., 1 tab

  14. Collective experiences of the young's through the period of political instabilities and the changes within the framework of collective identification in the territory of former Yugoslavia

    Directory of Open Access Journals (Sweden)

    Vasović Mirjana

    2008-01-01

    Full Text Available this study we illustrate and comparatively analyze collective - geopolitical - identifications of Former Yugoslav citizens in the context of a specific process of political transition that took place in its territory. The research into the breadth and character of this kind of group belonging has a great theoretical importance in predicting the development of specific intergroup attitudes (perception of other groups that inhabit the same social territory and, notably, intergroup relations. The study looks into geo-political affiliations (the sense of belonging to different geo-political communities of the same generation cohort (the subjects who were between 32 and 38 years old at the time of the research whose members were born in different historical periods and whose political socialization took place in different social and political circumstances. The direct aim of the secondary analysis of the data collected in two Former Yugoslav citizens' attitudes researches conducted in two different periods of Yugoslavia's transition - the very beginning, in 1990 and recently, in 2006 - was to establish the basic characteristics and possible changes in their geo-political affiliations, in terms of range and intensity. The analysis has shown that in the beginning of the transition (in the first period observed there was a greater geo-political affiliation differentiation within each subject, but that the majority still preferred Yugoslav nationality. The young from Slovenia and Kosovo represent paradigmatic exceptions that manifest a dramatic decrease in collective identification awareness even at this early stage. This growing trend which, in terms of psychology, represented a transition from the national and civil to ethnic-territorial model of collective identification, gradually takes over the consciousness of the citizens in all new-formed national countries. At the same time, the structure becomes more uniform. The factor analysis based on the

  15. Miniature Blimps for Surveillance and Collection of Samples

    Science.gov (United States)

    Jones, Jack

    2004-01-01

    Miniature blimps are under development as robots for use in exploring the thick, cold, nitrogen atmosphere of Saturn's moon, Titan. Similar blimps can also be used for surveillance and collection of biochemical samples in buildings, caves, subways, and other, similar structures on Earth. The widely perceived need for means to thwart attacks on buildings and to mitigate the effects of such attacks has prompted consideration of the use of robots. Relative to rover-type (wheeled) robots that have been considered for such uses, miniature blimps offer the advantage of ability to move through the air in any direction and, hence, to perform tasks that are difficult or impossible for wheeled robots, including climbing stairs and looking through windows. In addition, miniature blimps are expected to have greater range and to cost less, relative to wheeled robots.

  16. Comparison of three media for transport and storage of the samples collected for detection of avian influenza virus.

    Science.gov (United States)

    Zhang, Xiao-Chun; Liu, Shuo; Hou, Guang-Yu; Zhuang, Qing-Ye; Wang, Kai-Cheng; Jiang, Wen-Ming; Wang, Su-Chun; Li, Jin-Ping; Yu, Jian-Min; Du, Xiang; Huang, Bao-Xu; Chen, Ji-Ming

    2015-09-15

    Detection of avian influenza viruses (AIVs) is important for diagnosis, surveillance and control of avian influenza which is of great economic and public health significance. Proper transport and storage of samples is critical for the detection when the samples cannot be detected immediately. As recommended by some international or national authoritative entities and some publications, phosphate buffered saline (PBS), PBS-glycerol and brain heart infusion broth (BHIB) are frequently used for transport and storage of the samples collected for detection of AIVs worldwide. In this study, we compared these three media for transport and storage of simulated and authentic swab and feces samples collected for detection of AIVs using virus isolation and reverse transcription-PCR. The results suggest that PBS-glycerol is superior to PBS and BHIB as the sample transport and storage media. The results also suggest that the samples collected for detection of AIVs should be detected as soon as possible because the virus concentration of the samples may decline rapidly during storage within days at 4 or -20°C. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. A Systematic Review of Published Respondent-Driven Sampling Surveys Collecting Behavioral and Biologic Data.

    Science.gov (United States)

    Johnston, Lisa G; Hakim, Avi J; Dittrich, Samantha; Burnett, Janet; Kim, Evelyn; White, Richard G

    2016-08-01

    Reporting key details of respondent-driven sampling (RDS) survey implementation and analysis is essential for assessing the quality of RDS surveys. RDS is both a recruitment and analytic method and, as such, it is important to adequately describe both aspects in publications. We extracted data from peer-reviewed literature published through September, 2013 that reported collected biological specimens using RDS. We identified 151 eligible peer-reviewed articles describing 222 surveys conducted in seven regions throughout the world. Most published surveys reported basic implementation information such as survey city, country, year, population sampled, interview method, and final sample size. However, many surveys did not report essential methodological and analytical information for assessing RDS survey quality, including number of recruitment sites, seeds at start and end, maximum number of waves, and whether data were adjusted for network size. Understanding the quality of data collection and analysis in RDS is useful for effectively planning public health service delivery and funding priorities.

  18. Theorical and practical bases for blood sample collection from the heel of newborns for neonatal screening

    Directory of Open Access Journals (Sweden)

    Marcela Vela-Amieva

    2014-07-01

    collected in a special filter paper (Guthrie’s card. Despite its apparent simplicity, NBS laboratories commonly receive a large number of samples collected incorrectly and technically unsuitable for perfor4ming biochemical determinations. The aim of the present paper is to offer recommendations based on scientific evidence, for the properly blood collection on filter paper for NBS programs.

  19. Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories.

    Science.gov (United States)

    Wallin, Olof; Söderberg, Johan; Van Guelpen, Bethany; Stenlund, Hans; Grankvist, Kjell; Brulin, Christine

    2010-09-01

    Scand J Caring Sci; 2010; 24; 581-591 
 Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories   Most errors in venous blood testing result from human mistakes occurring before the sample reach the laboratory.   To survey venous blood sampling (VBS) practices in hospital wards and to compare practices with hospital laboratories.   Staff in two hospitals (all wards) and two hospital laboratories (314 respondents, response rate 94%), completed a questionnaire addressing issues relevant to the collection of venous blood samples for clinical chemistry testing.   The findings suggest that instructions for patient identification and the collection of venous blood samples were not always followed. For example, 79% of the respondents reported the undesirable practice (UDP) of not always using wristbands for patient identification. Similarly, 87% of the respondents noted the UDP of removing venous stasis after the sampling is finished. Compared with the ward staff, a significantly higher proportion of the laboratory staff reported desirable practices regarding the collection of venous blood samples. Neither education nor the existence of established sampling routines was clearly associated with VBS practices among the ward staff.   The results of this study, the first of its kind, suggest that a clinically important risk of error is associated with VBS in the surveyed wards. Most important is the risk of misidentification of patients. Quality improvement of blood sample collection is clearly needed, particularly in hospital wards. © 2009 The Authors. Journal compilation © 2009 Nordic College of Caring Science.

  20. Collecting Samples for Testing

    Science.gov (United States)

    ... Creatinine Ratio Valproic Acid Vancomycin Vanillylmandelic Acid (VMA) VAP Vitamin A Vitamin B12 and Folate Vitamin D ... that used for CSF in that they require aspiration of a sample of the fluid through a ...

  1. Persistent organic pollutants in biota samples collected during the Ymer-80 expedition to the Arctic

    Directory of Open Access Journals (Sweden)

    Henrik Kylin

    2015-10-01

    Full Text Available During the 1980 expedition to the Arctic with the icebreaker Ymer, a number of vertebrate species were sampled for determination of persistent organic pollutants. Samples of Arctic char (Salvelinus alpinus, n=34, glaucous gull (Larus hyperboreus, n=8, common eider (Somateria mollissima, n=10, Brünnich's guillemot (Uria lomvia, n=9, ringed seal (Pusa hispida, n=2 and polar bear (Ursus maritimus, n=2 were collected. With the exception of Brünnich's guillemot, there was a marked contamination difference of birds from western as compared to eastern/northern Svalbard. Samples in the west contained a larger number of polychlorinated biphenyl (PCB congeners and also polychlorinated terphenyls, indicating local sources. Brünnich's guillemots had similar pollutant concentrations in the west and east/north; possibly younger birds were sampled in the west. In Arctic char, pollutant profiles from lake Linnévatn (n=5, the lake closest to the main economic activities in Svalbard, were similar to profiles in Arctic char from the Shetland Islands (n=5, but differed from lakes to the north and east in Svalbard (n=30. Arctic char samples had higher concentrations of hexachlorocyclohexanes (HCHs than the marine species of birds and mammals, possibly due to accumulation via snowmelt. Compared to the Baltic Sea, comparable species collected in Svalbard had lower concentrations of PCB and dichlorodiphenyltrichloroethane (DDT, but similar concentrations indicating long-range transport of hexachlorobenzene, HCHs and cyclodiene pesticides. In samples collected in Svalbard in 1971, the concentrations of PCB and DDT in Brünnich's guillemot (n=7, glaucous gull (n=2 and polar bear (n=2 were similar to the concentrations found in 1980.

  2. Next Generation Offline Approaches to Trace Gas-Phase Organic Compound Speciation: Sample Collection and Analysis

    Science.gov (United States)

    Sheu, R.; Marcotte, A.; Khare, P.; Ditto, J.; Charan, S.; Gentner, D. R.

    2017-12-01

    Intermediate-volatility and semi-volatile organic compounds (I/SVOCs) are major precursors to secondary organic aerosol, and contribute to tropospheric ozone formation. Their wide volatility range, chemical complexity, behavior in analytical systems, and trace concentrations present numerous hurdles to characterization. We present an integrated sampling-to-analysis system for the collection and offline analysis of trace gas-phase organic compounds with the goal of preserving and recovering analytes throughout sample collection, transport, storage, and thermal desorption for accurate analysis. Custom multi-bed adsorbent tubes are used to collect samples for offline analysis by advanced analytical detectors. The analytical instrumentation comprises an automated thermal desorption system that introduces analytes from the adsorbent tubes into a gas chromatograph, which is coupled with an electron ionization mass spectrometer (GC-EIMS) and other detectors. In order to optimize the collection and recovery for a wide range of analyte volatility and functionalization, we evaluated a variety of commercially-available materials, including Res-Sil beads, quartz wool, glass beads, Tenax TA, and silica gel. Key properties for optimization include inertness, versatile chemical capture, minimal affinity for water, and minimal artifacts or degradation byproducts; these properties were assessed with a diverse mix of traditionally-measured and functionalized analytes. Along with a focus on material selection, we provide recommendations spanning the entire sampling-and-analysis process to improve the accuracy of future comprehensive I/SVOC measurements, including oxygenated and other functionalized I/SVOCs. We demonstrate the performance of our system by providing results on speciated VOCs-SVOCs from indoor, outdoor, and chamber studies that establish the utility of our protocols and pave the way for precise laboratory characterization via a mix of detection methods.

  3. Autonomous spatially adaptive sampling in experiments based on curvature, statistical error and sample spacing with applications in LDA measurements

    Science.gov (United States)

    Theunissen, Raf; Kadosh, Jesse S.; Allen, Christian B.

    2015-06-01

    Spatially varying signals are typically sampled by collecting uniformly spaced samples irrespective of the signal content. For signals with inhomogeneous information content, this leads to unnecessarily dense sampling in regions of low interest or insufficient sample density at important features, or both. A new adaptive sampling technique is presented directing sample collection in proportion to local information content, capturing adequately the short-period features while sparsely sampling less dynamic regions. The proposed method incorporates a data-adapted sampling strategy on the basis of signal curvature, sample space-filling, variable experimental uncertainty and iterative improvement. Numerical assessment has indicated a reduction in the number of samples required to achieve a predefined uncertainty level overall while improving local accuracy for important features. The potential of the proposed method has been further demonstrated on the basis of Laser Doppler Anemometry experiments examining the wake behind a NACA0012 airfoil and the boundary layer characterisation of a flat plate.

  4. Establishment of a cervical cancer bio-bank for the Chinese population: from project-based sample collection to routine management.

    Science.gov (United States)

    Yang, Ru; Li, Xiong; Zhou, Hang; Jia, Yao; Zhou, Jin; Huang, Kecheng; Tang, Fangxu; Hu, Ting; Shen, Jian; Chen, Zhilan; Wang, Shaoshuai; Sun, Haiying; Guo, Lili; Wang, Lin; Wang, Hui; Ma, Ding; Li, Shuang

    2015-08-01

    There is an increasing need for the establishment of a cervical cancer bio-bank that will facilitate both clinical and basic research. The cervical cancer bio-bank was first established in January 1999 and included two stages. First, a GWAS-based sample collection was conducted with special emphasis on the diagnosis and the retrieval of the corresponding bio-specimens, especially blood samples. Second, clinical data and their corresponding bio-specimens were routinely collected and handled. Notably, these bio-specimens also included samples from Wufeng Tujia Autonomous County, which has the highest incidence of cervical cancer in China. The specimens were collected from patients with cervical cancer and those with cervical intraepithelial neoplasia, while the control samples were collected from normal individuals. With special emphasis on clinical data and blood samples for the GWAS analysis, the collection of other bio-specimens was slow, and the pairing of specimens and clinical data was poor during the first stage. However, in the second stage, the pairing of the clinical data and its corresponding bio-specimens improved. At present, the samples procured and preserved in the bio-bank cover most regions of China and different ethnic groups for both the normal controls and cervical cancer patients of different pathological categories. This bio-bank of cervical cancer specimens from the Chinese population will greatly promote the studies of cervical cancer in China.

  5. Use of aspiration method for collecting brain samples for rabies diagnosis in small wild animals.

    Science.gov (United States)

    Iamamoto, K; Quadros, J; Queiroz, L H

    2011-02-01

    In developing countries such as Brazil, where canine rabies is still a considerable problem, samples from wildlife species are infrequently collected and submitted for screening for rabies. A collaborative study was established involving environmental biologists and veterinarians for rabies epidemiological research in a specific ecological area located at the Sao Paulo State, Brazil. The wild animals' brains are required to be collected without skull damage because the skull's measurements are important in the identification of the captured animal species. For this purpose, samples from bats and small mammals were collected using an aspiration method by inserting a plastic pipette into the brain through the magnum foramen. While there is a progressive increase in the use of the plastic pipette technique in various studies undertaken, it is also appreciated that this method could foster collaborative research between wildlife scientists and rabies epidemiologists thus improving rabies surveillance. © 2009 Blackwell Verlag GmbH.

  6. Waste tank vapor project: Vapor characterization of Tank 241-C-103: Data report for OVS samples collected from Sample Job 7b, Parts I and II, received 5/18/94 and 5/24/94

    International Nuclear Information System (INIS)

    Clauss, T.R.; Edwards, J.A.; Fruchter, J.S.

    1994-09-01

    On 5/18/94, Westinghouse Hanford Company (WHC) delivered samples to Pacific Northwest Laboratory (PNL) that were collected from waste Tank 241-C-103 on 5/16/94. These samples were from Sample Job (SJ) 7b, Part 1. On 5/24/94, WHC delivered samples to PNL that were collected from waste Tank 241-C-103 on 5/18/94. These samples were from SJ7b, Part 2. A summary of data derived from the sampling of waste Tank 241-C-103 for gravimetric (H 2 O) and normal paraffin hydrocarbon (NPH) concentrations are shown for SJ7b. Gravimetric analysis was performed on the samples within 24 hours of receipt by PNL. The NPH concentration of 10 samples collected for Part 1 was slightly higher than the average concentration for 15 samples collected in Part 2, 812 (± 133) mg/m 3 and 659 (± 88) mg/m 3 , respectively. The higher concentrations measured in Part 1 samples may be because the samples in Part 1 were collected at a single level, 0.79 meters above the air-liquid interface. Part 2 samples were collected at three different tank levels, 0.79, 2.92, and 5.05 m above the air-liquid interface. In Part 2, the average NPH concentrations for 5 samples collected at each of three levels was similar: 697 (60) mg/m 3 at the low level, 631 (51) mg/m 3 at the mid level, and 651 (134) mg/m 3 at the high level. It is important to note that the measured tridecane to dodecane concentration remained constant in all samples collected in Parts 1 and 2. That ratio is 1.2 ± 0.05. This consistent ratio indicates that there were no random analytical biases towards either compound

  7. Radioactivity in Soil Samples Collected in Southern Serbia

    International Nuclear Information System (INIS)

    Jankovic, M.; Nikolic, J.; Pantelic, G.; Rajacic, M.; Sarap, N.; Todorovic, D.

    2013-01-01

    In the attack on the Federal Republic of Yugoslavia (the focus effect was of Kosovo and Metohija and southern Serbia) in 1999, NATO forces used ammunition containing depleted uranium. Cleaning action of depleted uranium was performed by Radiation and Environmental Protection Department of the Vinca Institute of Nuclear Science, during 2002?2007 at locations: Pljackovica, Bratoselce, Borovac and Reljan. At all locations underwent detailed dosimetric screening and decontamination was performed. Because of the loose soil, DU projectils were found to a depth of 1 m. Found missiles, contaminated soil and radioactive material has been collected and stored on radioactive waste. After cleaning the ground is leveled and another dosimetric prospecting was performed. Monitoring of radioactivity in southern Serbia included determination of gamma emitters as well as determination of gross alpha and beta activities in soil, water and plant. Sampling was carried out at Pljackovica, Borovac, Bratoselce and Reljan in July 2011. This paper presents only the results of measurement of gamma emitters in soil samples and showed the presence of natural radionuclides: 226Ra, 232Th, 40K, 235U, 238U and the produced radionuclide 137Cs (from the Chernobyl accident). Also, the ratio between the 235U and 238U is given. In order to evaluate the radiological hazard of the natural radioactivity, the radium equivalent activity, the gamma-absorbed dose rate and the external hazard index have been calculated. (author)

  8. Aspergillus, Penicillium and Talaromyces isolated from house dust samples collected around the world

    NARCIS (Netherlands)

    Visagie, C M; Hirooka, Y; Tanney, J B; Whitfield, E; Mwange, K; Meijer, M; Amend, A S; Seifert, K A; Samson, R A

    As part of a worldwide survey of the indoor mycobiota, dust was collected from nine countries. Analyses of dust samples included the culture-dependent dilution-to-extinction method and the culture-independent 454-pyrosequencing. Of the 7 904 isolates, 2 717 isolates were identified as belonging to

  9. Analysis of Dust Samples Collected from an In-Service Interim Storage System at the Maine Yankee Nuclear Site.

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Charles R.; Enos, David

    2016-10-01

    In July, 2016, the Electric Power Research Institute and industry partners performed a field test at the Maine Yankee Nuclear Site, located near Wiscasset, Maine. The primary goal of the field test was to evaluate the use of robots in surveying the surface of an in-service interim storage canister within an overpack; however, as part of the demonstration, dust and soluble salt samples were collected from horizontal surfaces within the interim storage system. The storage system is a vertical system made by NAC International, consisting of a steel-lined concrete overpack containing a 304 stainless steel (SS) welded storage canister. The canister did not contain spent fuel but rather greater-than-class-C waste, which did not generate significant heat, limiting airflow through the storage system. The surfaces that were sampled for deposits included the top of the shield plug, the side of the canister, and a shelf at the bottom of the overpack, just below the level of the pillar on which the canister sits. The samples were sent to Sandia National Laboratories for analysis. This report summarizes the results of those analyses. Because the primary goal of the field test was to evaluate the use of robots in surveying the surface of the canister within the overpack, collection of dust samples was carried out in a qualitative fashion, using paper filters and sponges as the sampling media. The sampling focused mostly on determining the composition of soluble salts present in the dust. It was anticipated that a wet substrate would more effectively extract soluble salts from the surface that was sampled, so both the sponges and the filter paper were wetted prior to being applied to the surface of the metal. Sampling was accomplished by simply pressing the damp substrate against the metal surface for two minutes, and then removing it. It is unlikely that the sampling method quantitatively collected dust or salts from the metal surface; however, both substrates did extract a

  10. Water-quality assessment of south-central Texas : comparison of water quality in surface-water samples collected manually and by automated samplers

    Science.gov (United States)

    Ging, Patricia B.

    1999-01-01

    Surface-water sampling protocols of the U.S. Geological Survey National Water-Quality Assessment (NAWQA) Program specify samples for most properties and constituents to be collected manually in equal-width increments across a stream channel and composited for analysis. Single-point sampling with an automated sampler (autosampler) during storms was proposed in the upper part of the South-Central Texas NAWQA study unit, raising the question of whether property and constituent concentrations from automatically collected samples differ significantly from those in samples collected manually. Statistical (Wilcoxon signed-rank test) analyses of 3 to 16 paired concentrations for each of 26 properties and constituents from water samples collected using both methods at eight sites in the upper part of the study unit indicated that there were no significant differences in concentrations for dissolved constituents, other than calcium and organic carbon.

  11. Comparison of mobile and stationary spore-sampling techniques for estimating virulence frequencies in aerial barley powdery mildew populations

    DEFF Research Database (Denmark)

    Hovmøller, M.S.; Munk, L.; Østergård, Hanne

    1995-01-01

    Gene frequencies in samples of aerial populations of barley powdery mildew (Erysiphe graminis f.sp. hordei), which were collected in adjacent barley areas and in successive periods of time, were compared using mobile and stationary sampling techniques. Stationary samples were collected from trap ...

  12. Critical study of common conditions of storage of glucocorticoids and catecholamines in 24-h urine collected during resting and exercising conditions.

    Science.gov (United States)

    Gouarne, C; Foury, A; Duclos, M

    2004-10-01

    Except immediate freezing of the samples, no practical method has been validated for preservation of glucocorticoids and catecholamines in 24-h urine collection. Furthermore, the influence of urine storage at bladder temperature during periods of different lengths and the effect of prior exercise on preservation of these hormones in the bladder have not been investigated until now. Ten healthy volunteers collected their urine both after a resting and after an exercise session. Urine was aliquoted into tubes which were stored during 24 h in the presence or in the absence of preservatives and at different temperatures. Two samples were stored either 3 or 9 h at 37 degrees C (bladder temperature) without additive. When collecting 24-h urine samples for glucocorticoids determination, sample can be stored at room temperature during the 24-h collection period without compromising glucocorticoids preservation. When collecting 24-h urine samples for catecholamines determination, samples have to be chilled without preservative during the whole of the collection period. If the samples have to be stored at room temperature, HCl should be used. Moreover, we report for the first time that catecholamines can be degraded in the bladder and therefore that subjects should urinate every 3 h during either a resting or an exercising day.

  13. Validation of a Sampling Method to Collect Exposure Data for Central-Line-Associated Bloodstream Infections.

    Science.gov (United States)

    Hammami, Naïma; Mertens, Karl; Overholser, Rosanna; Goetghebeur, Els; Catry, Boudewijn; Lambert, Marie-Laurence

    2016-05-01

    Surveillance of central-line-associated bloodstream infections requires the labor-intensive counting of central-line days (CLDs). This workload could be reduced by sampling. Our objective was to evaluate the accuracy of various sampling strategies in the estimation of CLDs in intensive care units (ICUs) and to establish a set of rules to identify optimal sampling strategies depending on ICU characteristics. Analyses of existing data collected according to the European protocol for patient-based surveillance of ICU-acquired infections in Belgium between 2004 and 2012. CLD data were reported by 56 ICUs in 39 hospitals during 364 trimesters. We compared estimated CLD data obtained from weekly and monthly sampling schemes with the observed exhaustive CLD data over the trimester by assessing the CLD percentage error (ie, observed CLDs - estimated CLDs/observed CLDs). We identified predictors of improved accuracy using linear mixed models. When sampling once per week or 3 times per month, 80% of ICU trimesters had a CLD percentage error within 10%. When sampling twice per week, this was >90% of ICU trimesters. Sampling on Tuesdays provided the best estimations. In the linear mixed model, the observed CLD count was the best predictor for a smaller percentage error. The following sampling strategies provided an estimate within 10% of the actual CLD for 97% of the ICU trimesters with 90% confidence: 3 times per month in an ICU with >650 CLDs per trimester or each Tuesday in an ICU with >480 CLDs per trimester. Sampling of CLDs provides an acceptable alternative to daily collection of CLD data.

  14. Estimation of creatinine in Urine sample by Jaffe's method

    International Nuclear Information System (INIS)

    Wankhede, Sonal; Arunkumar, Suja; Sawant, Pramilla D.; Rao, B.B.

    2012-01-01

    In-vitro bioassay monitoring is based on the determination of activity concentrations in biological samples excreted from the body and is most suitable for alpha and beta emitters. A truly representative bioassay sample is the one having all the voids collected during a 24-h period however, this being technically difficult, overnight urine samples collected by the workers are analyzed. These overnight urine samples are collected for 10-16 h, however in the absence of any specific information, 12 h duration is assumed and the observed results are then corrected accordingly obtain the daily excretion rate. To reduce the uncertainty due to unknown duration of sample collection, IAEA has recommended two methods viz., measurement of specific gravity and creatinine excretion rate in urine sample. Creatinine is a final metabolic product creatinine phosphate in the body and is excreted at a steady rate for people with normally functioning kidneys. It is, therefore, often used as a normalization factor for estimation of duration of sample collection. The present study reports the chemical procedure standardized and its application for the estimation of creatinine in urine samples collected from occupational workers. Chemical procedure for estimation of creatinine in bioassay samples was standardized and applied successfully for its estimation in bioassay samples collected from the workers. The creatinine excretion rate observed for these workers is lower than observed in literature. Further, work is in progress to generate a data bank of creatinine excretion rate for most of the workers and also to study the variability in creatinine coefficient for the same individual based on the analysis of samples collected for different duration

  15. A Hybrid Algorithm for Period Analysis from Multiband Data with Sparse and Irregular Sampling for Arbitrary Light-curve Shapes

    Science.gov (United States)

    Saha, Abhijit; Vivas, A. Katherina

    2017-12-01

    Ongoing and future surveys with repeat imaging in multiple bands are producing (or will produce) time-spaced measurements of brightness, resulting in the identification of large numbers of variable sources in the sky. A large fraction of these are periodic variables: compilations of these are of scientific interest for a variety of purposes. Unavoidably, the data sets from many such surveys not only have sparse sampling, but also have embedded frequencies in the observing cadence that beat against the natural periodicities of any object under investigation. Such limitations can make period determination ambiguous and uncertain. For multiband data sets with asynchronous measurements in multiple passbands, we wish to maximally use the information on periodicity in a manner that is agnostic of differences in the light-curve shapes across the different channels. Given large volumes of data, computational efficiency is also at a premium. This paper develops and presents a computationally economic method for determining periodicity that combines the results from two different classes of period-determination algorithms. The underlying principles are illustrated through examples. The effectiveness of this approach for combining asynchronously sampled measurements in multiple observables that share an underlying fundamental frequency is also demonstrated.

  16. Method for rapid screening analysis of Sr-90 in edible plant samples collected near Fukushima, Japan

    International Nuclear Information System (INIS)

    Amano, Hikaru; Sakamoto, Hideaki; Shiga, Norikatsu; Suzuki, Kaori

    2016-01-01

    A screening method for measuring 90 Sr in edible plant samples by focusing on 90 Y in equilibrium with 90 Sr is reported. 90 Y was extracted from samples with acid, co-precipitated with iron hydroxide, and precipitated with oxalic acid. The dissolved oxalate precipitate was loaded on an extraction chromatography resin, and the 90 Y-enriched eluate was analyzed by Cherenkov counting with a TDCR liquid scintillation counter. 90 Sr ( 90 Y) concentration was determined in plant samples collected near the damaged Fukushima Daiichi Nuclear Power Plants with this method. - Highlights: • A screening method for measuring 90 Sr in edible plant samples by focusing on 90 Y in equilibrium with 90 Sr is reported. • 90 Y was extracted from samples with acid, co-precipitated with iron hydroxide, and precipitated with oxalic acid. • The dissolved oxalate precipitate was loaded on an extraction chromatography resin. • 90 Y-enriched eluate was analyzed by Cherenkov counting with a TDCR liquid scintillation counter. • 90 Sr ( 90 Y) concentration was determined in edible plant samples collected near the damaged Fukushima Daiichi NPPs with this method.

  17. Ram-air sample collection device for a chemical warfare agent sensor

    Science.gov (United States)

    Megerle, Clifford A.; Adkins, Douglas R.; Frye-Mason, Gregory C.

    2002-01-01

    In a surface acoustic wave sensor mounted within a body, the sensor having a surface acoustic wave array detector and a micro-fabricated sample preconcentrator exposed on a surface of the body, an apparatus for collecting air for the sensor, comprising a housing operatively arranged to mount atop the body, the housing including a multi-stage channel having an inlet and an outlet, the channel having a first stage having a first height and width proximate the inlet, a second stage having a second lower height and width proximate the micro-fabricated sample preconcentrator, a third stage having a still lower third height and width proximate the surface acoustic wave array detector, and a fourth stage having a fourth height and width proximate the outlet, where the fourth height and width are substantially the same as the first height and width.

  18. Distribution of 10 periodontal bacterial species in children and adolescents over a 7-year period.

    Science.gov (United States)

    Nakano, K; Miyamoto, E; Tamura, K; Nemoto, H; Fujita, K; Nomura, R; Ooshima, T

    2008-10-01

    There is scant information available regarding the distribution of periodontal bacterial species in children and adolescents over an extended period. The purpose of this study was to compare bacterial profiles in the same individuals over a period of 7 years. Twenty-six children and adolescents from whom dental plaque and saliva specimens were obtained during both the first (1999-2000) and second (2006-2007) periods, were analyzed. Bacterial DNA was extracted from each specimen and the presence of 10 periodontal bacterial species was determined using a PCR method, with a focus on the red complex species of Porphyromonas gingivalis, Treponema denticola, and Tannerella forsythia. Subjects with red complex species in saliva specimens obtained during the second collection possessed a significantly higher number of total bacterial species than those without. The detection rate of the red complex species in the second collection period samples was significantly greater in subjects who had two or more species detected in samples taken during the first collection compared with the other subjects. Subjects possessing red complex species may be at possible risk for infection with a high number of periodontal bacterial species during adolescent and younger adult years.

  19. Analytical Values for Mushroom Compost, Poultry Deep Litter and Poultry Slurry Samples over a 5 Year Period 1978-82

    OpenAIRE

    Gormley, T. R. (Thomas Ronan); Staunton, L.

    1984-01-01

    Data are presented on the analysis of mushroom compost, poultry deep litter and poultry slurry samples over the period 1978-82. There was no difference in the dry matter (DM) content of compost samples between years either at time of filling or spawning, with mean values of 32 and 29%, respectively. The DM values were highest in the April-September period. Nitrogen (N) values were not different on an annual or quarterly basis, with means of 2.21 and 1.99%, on a DM basis, at spawning and filli...

  20. Tritium concentrations in environmental water and food samples collected around the vicinity of the PNPP-1

    International Nuclear Information System (INIS)

    Garcia, T.Y.; Enriquez, S.O.; Duran, E.B.

    1986-01-01

    The natural radioactivity levels of tritium in environmental samples collected around the vicinity and more distant environment of the first Philippine Nuclear Power Plant (PNPP-1) in Bataan were assessed. The samples analyzed consisted of water samples such as seawater, freshwater, drinking water, groundwater and rainwater; and food samples such as cereals, vegetables, fruits; meat, milk fish and crustaceans. Tritium concentrations in water samples were determined by distillation and liquid scintillation counting techniques. The food samples were analyzed for tissue-free water tritium by the freezing-drying method followed by liquid scintillation counting techniques. (Auth.) 13 refs

  1. The UK Biobank sample handling and storage protocol for the collection, processing and archiving of human blood and urine.

    Science.gov (United States)

    Elliott, Paul; Peakman, Tim C

    2008-04-01

    UK Biobank is a large prospective study in the UK to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. Extensive data and biological samples are being collected from 500,000 participants aged between 40 and 69 years. The biological samples that are collected and how they are processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. The aim of the UK Biobank sample handling and storage protocol is to specify methods for the collection and storage of participant samples that give maximum scientific return within the available budget. Processing or storage methods that, as far as can be predicted, will preclude current or future assays have been avoided. The protocol was developed through a review of the literature on sample handling and processing, wide consultation within the academic community and peer review. Protocol development addressed which samples should be collected, how and when they should be processed and how the processed samples should be stored to ensure their long-term integrity. The recommended protocol was extensively tested in a series of validation studies. UK Biobank collects about 45 ml blood and 9 ml of urine with minimal local processing from each participant using the vacutainer system. A variety of preservatives, anti-coagulants and clot accelerators is used appropriate to the expected end use of the samples. Collection of other material (hair, nails, saliva and faeces) was also considered but rejected for the full cohort. Blood and urine samples from participants are transported overnight by commercial courier to a central laboratory where they are processed and aliquots of urine, plasma, serum, white cells and red cells stored in ultra-low temperature archives. Aliquots of whole blood are also stored for potential future production of immortalized cell lines. A standard panel of haematology assays is

  2. Reducing the sampling periods required in protocols for establishing ammonia emissions from pig fattening buildings using measurements and modelling

    NARCIS (Netherlands)

    Mosquera Losada, J.; Ogink, N.W.M.

    2011-01-01

    Ammonia (NH(3)) emission factors for animal housing systems in the Netherlands are based on measurements using standardised measurement protocols. Both the original Green Label (GL) protocol and the newly developed multi-site sampling protocol are based on year-round sampling periods. The objective

  3. Airborne detection and quantification of swine influenza a virus in air samples collected inside, outside and downwind from swine barns.

    Directory of Open Access Journals (Sweden)

    Cesar A Corzo

    Full Text Available Airborne transmission of influenza A virus (IAV in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m³ of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m³ of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m³. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions.

  4. Influence of lactation stages and rain periods on subclinical mastitis in meat producing ewes

    Directory of Open Access Journals (Sweden)

    Luiz Francisco Zafalon

    Full Text Available ABSTRACT: Mastitis negatively influences the survival and weight gain of ovines for meat production. The purpose of this study was to investigate, in sheep for meat production, the occurrence of subclinical mastitis in ewes at the end of lactation and beginning of the consecutive lactation and to assess the composition and cellular characteristics of milk as a function of different rainfall indices. Mammary halves (821 of Santa Ines (479 and Morada Nova (342 ewes were examined. Milk samples were collected in two different moments of lactation: at weaning and postpartum of the consecutive lactation. Sample collection periods were called "dry" or "rainy" according to the rainfall index in the month immediately before the month of collection. The occurrence of subclinical mastitis at weaning in the Santa Ines and Morada Nova ewes were 16.4 and 12.6% in the dry period, and 17.7 and 23.5% in the rainy period, respectively. In the consecutive lactation period, the occurrences were 26.7 and 27.7% in the dry period and 41.8 and 39.1% in the rainy period, for the Santa Ines and Morada Nova ewes, respectively. Postpartum stage was critical for the occurrence of subclinical mastitis, as compared to that at the end of the previous lactation. Occurrence of the disease negatively influenced the SCC in the milk at the beginning of lactation and changed its composition, mainly in the rainiest periods, probably due to a difficulty in maintaining hygiene in the environment where the animals remained.

  5. The influence of moonlight and lunar periodicity on the efficacy of CDC light trap in sampling Phlebotomus (Larroussius) orientalis Parrot, 1936 and other Phlebotomus sandflies (Diptera: Psychodidae) in Ethiopia.

    Science.gov (United States)

    Gebresilassie, Araya; Yared, Solomon; Aklilu, Essayas; Kirstein, Oscar David; Moncaz, Aviad; Tekie, Habte; Balkew, Meshesha; Warburg, Alon; Hailu, Asrat; Gebre-Michael, Teshome

    2015-02-15

    Phlebotomus orientalis is the main sandfly vector of visceral leishmaniasis in the north and northwest of Ethiopia. CDC light traps and sticky traps are commonly used for monitoring sandfly populations. However, their trapping efficiency is greatly influenced by various environmental factors including moonlight and lunar periodicity. In view of that, the current study assessed the effect of moonlight and lunar periodicity on the performance of light traps in collecting P. orientalis. Trapping of P. orientalis and other Phlebotomus spp. was conducted for 7 months between December 2012 and June 2013 using CDC light traps and sticky traps from peri-domestic and agricultural fields. Throughout the trapping periods, collections of sandfly specimens were carried out for 4 nights per month, totaling 28 trapping nights that coincided with the four lunar phases (viz., first quarter, third quarter, new and full moon) distributed in each month. In total, 13,533 sandflies of eight Phlebotomus species (P. orientalis, P. bergeroti, P. rodhaini, P. duboscqi, P. papatasi, P. martini, P. lesleyae and P. heischi) were recorded. The predominant species was P. orientalis in both trapping sites and by both methods of collection in all lunar phases. A significant difference (P lunar phases. The highest mean number (231.13 ± 36.27 flies/trap/night) of P. orientalis was collected during the new moon phases, when the moonlight is absent. Fewer sandflies were attracted to light traps during a full moon. However, the number of P. orientalis and the other Phlebotomus spp. from sticky traps did not differ in their density among the four lunar phases (P = 0.122). Results of the current study demonstrated that the attraction and trapping efficiency of CDC light traps is largely influenced by the presence moonlight, especially during a full moon. Therefore, sampling of sandflies using light traps to estimate population density and other epidemiological studies in the field should take

  6. Aerosol Sampling System for Collection of Capstone Depleted Uranium Particles in a High-Energy Environment

    International Nuclear Information System (INIS)

    Holmes, Thomas D.; Guilmette, Raymond A.; Cheng, Yung-Sung; Parkhurst, MaryAnn; Hoover, Mark D.

    2009-01-01

    The Capstone Depleted Uranium Aerosol Study was undertaken to obtain aerosol samples resulting from a kinetic-energy cartridge with a large-caliber depleted uranium (DU) penetrator striking an Abrams or Bradley test vehicle. The sampling strategy was designed to (1) optimize the performance of the samplers and maintain their integrity in the extreme environment created during perforation of an armored vehicle by a DU penetrator, (2) collect aerosols as a function of time post-impact, and (3) obtain size-classified samples for analysis of chemical composition, particle morphology, and solubility in lung fluid. This paper describes the experimental setup and sampling methodologies used to achieve these objectives. Custom-designed arrays of sampling heads were secured to the inside of the target in locations approximating the breathing zones of the vehicle commander, loader, gunner, and driver. Each array was designed to support nine filter cassettes and nine cascade impactors mounted with quick-disconnect fittings. Shielding and sampler placement strategies were used to minimize sampler loss caused by the penetrator impact and the resulting fragments of eroded penetrator and perforated armor. A cyclone train was used to collect larger quantities of DU aerosol for chemical composition and solubility. A moving filter sample was used to obtain semicontinuous samples for depleted uranium concentration determination. Control for the air samplers was provided by five remotely located valve control and pressure monitoring units located inside and around the test vehicle. These units were connected to a computer interface chassis and controlled using a customized LabVIEW engineering computer control program. The aerosol sampling arrays and control systems for the Capstone study provided the needed aerosol samples for physicochemical analysis, and the resultant data were used for risk assessment of exposure to DU aerosol

  7. Measurement of DNA adducts and strand breaks in dab (Limanda limanda) collected in the field: effects of biotic (age, sex) and abiotic (sampling site and period) factors on the extent of DNA damage

    Energy Technology Data Exchange (ETDEWEB)

    Akcha, F.; Leday, G.; Pfohl-Leszkowicz, A

    2004-08-18

    In the Eastern English Channel, the potential application of the comet assay and post-labelling technique in dab was evaluated for genotoxicity monitoring of the marine environment. The effects of biotic (age, sex) and abiotic (sampling site and period) factors on the extent of DNA lesions were also studied. Female and male dab of two class of size (juvenile and adult) were collected by trawling in different sites in Seine Bay and Somme Bay during September 2001. Single-strand breaks and adducts were, respectively, measured in erythrocytes and the liver. Results obtained for the adult female were compared with those collected during a first cruise in March 2001 [Akcha et al., Mutat Res. 534 (1-2) (2003) 21]. Significant effects of sex and age were demonstrated on the level of strand breaks. Moreover, a significant interaction between age and sex was shown that might indicate the complex influence of other factors on the extent of DNA damage (i.e. reproduction status). In the adult dab, the level of breaks is higher in the male than in the female, whereas the opposite trend was observed for the juvenile. Whatever the sex, the number of DNA breaks is higher in the adult than in the juvenile. For the female dab, significant differences were observed with the comet assay between the Seine Bay and the Somme Bay in March but not in September. This may be due to seasonal variations in the formation of DNA lesions related to variations in lipid content and levels of biotransformation activities and/or to spawning cycles. The presence of genotoxic substances in the study areas was also confirmed by the detection of DNA adducts in each sample analysed. Whereas no effect was shown on the total level of adducts for the tested biotic and abiotic factors, qualitative differences in adduct profiles were observed for each of these factors. For the female dab, comparison of adduct profiles obtained in March and September with one generated by hepatic microsomal activation in dab of

  8. Molecular dynamics based enhanced sampling of collective variables with very large time steps

    Science.gov (United States)

    Chen, Pei-Yang; Tuckerman, Mark E.

    2018-01-01

    Enhanced sampling techniques that target a set of collective variables and that use molecular dynamics as the driving engine have seen widespread application in the computational molecular sciences as a means to explore the free-energy landscapes of complex systems. The use of molecular dynamics as the fundamental driver of the sampling requires the introduction of a time step whose magnitude is limited by the fastest motions in a system. While standard multiple time-stepping methods allow larger time steps to be employed for the slower and computationally more expensive forces, the maximum achievable increase in time step is limited by resonance phenomena, which inextricably couple fast and slow motions. Recently, we introduced deterministic and stochastic resonance-free multiple time step algorithms for molecular dynamics that solve this resonance problem and allow ten- to twenty-fold gains in the large time step compared to standard multiple time step algorithms [P. Minary et al., Phys. Rev. Lett. 93, 150201 (2004); B. Leimkuhler et al., Mol. Phys. 111, 3579-3594 (2013)]. These methods are based on the imposition of isokinetic constraints that couple the physical system to Nosé-Hoover chains or Nosé-Hoover Langevin schemes. In this paper, we show how to adapt these methods for collective variable-based enhanced sampling techniques, specifically adiabatic free-energy dynamics/temperature-accelerated molecular dynamics, unified free-energy dynamics, and by extension, metadynamics, thus allowing simulations employing these methods to employ similarly very large time steps. The combination of resonance-free multiple time step integrators with free-energy-based enhanced sampling significantly improves the efficiency of conformational exploration.

  9. Sampling free energy surfaces as slices by combining umbrella sampling and metadynamics.

    Science.gov (United States)

    Awasthi, Shalini; Kapil, Venkat; Nair, Nisanth N

    2016-06-15

    Metadynamics (MTD) is a very powerful technique to sample high-dimensional free energy landscapes, and due to its self-guiding property, the method has been successful in studying complex reactions and conformational changes. MTD sampling is based on filling the free energy basins by biasing potentials and thus for cases with flat, broad, and unbound free energy wells, the computational time to sample them becomes very large. To alleviate this problem, we combine the standard Umbrella Sampling (US) technique with MTD to sample orthogonal collective variables (CVs) in a simultaneous way. Within this scheme, we construct the equilibrium distribution of CVs from biased distributions obtained from independent MTD simulations with umbrella potentials. Reweighting is carried out by a procedure that combines US reweighting and Tiwary-Parrinello MTD reweighting within the Weighted Histogram Analysis Method (WHAM). The approach is ideal for a controlled sampling of a CV in a MTD simulation, making it computationally efficient in sampling flat, broad, and unbound free energy surfaces. This technique also allows for a distributed sampling of a high-dimensional free energy surface, further increasing the computational efficiency in sampling. We demonstrate the application of this technique in sampling high-dimensional surface for various chemical reactions using ab initio and QM/MM hybrid molecular dynamics simulations. Further, to carry out MTD bias reweighting for computing forward reaction barriers in ab initio or QM/MM simulations, we propose a computationally affordable approach that does not require recrossing trajectories. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  10. Feasibility of self-sampled dried blood spot and saliva samples sent by mail in a population-based study.

    Science.gov (United States)

    Sakhi, Amrit Kaur; Bastani, Nasser Ezzatkhah; Ellingjord-Dale, Merete; Gundersen, Thomas Erik; Blomhoff, Rune; Ursin, Giske

    2015-04-11

    In large epidemiological studies it is often challenging to obtain biological samples. Self-sampling by study participants using dried blood spots (DBS) technique has been suggested to overcome this challenge. DBS is a type of biosampling where blood samples are obtained by a finger-prick lancet, blotted and dried on filter paper. However, the feasibility and efficacy of collecting DBS samples from study participants in large-scale epidemiological studies is not known. The aim of the present study was to test the feasibility and response rate of collecting self-sampled DBS and saliva samples in a population-based study of women above 50 years of age. We determined response proportions, number of phone calls to the study center with questions about sampling, and quality of the DBS. We recruited women through a study conducted within the Norwegian Breast Cancer Screening Program. Invitations, instructions and materials were sent to 4,597 women. The data collection took place over a 3 month period in the spring of 2009. Response proportions for the collection of DBS and saliva samples were 71.0% (3,263) and 70.9% (3,258), respectively. We received 312 phone calls (7% of the 4,597 women) with questions regarding sampling. Of the 3,263 individuals that returned DBS cards, 3,038 (93.1%) had been packaged and shipped according to instructions. A total of 3,032 DBS samples were sufficient for at least one biomarker analysis (i.e. 92.9% of DBS samples received by the laboratory). 2,418 (74.1%) of the DBS cards received by the laboratory were filled with blood according to the instructions (i.e. 10 completely filled spots with up to 7 punches per spot for up to 70 separate analyses). To assess the quality of the samples, we selected and measured two biomarkers (carotenoids and vitamin D). The biomarker levels were consistent with previous reports. Collecting self-sampled DBS and saliva samples through the postal services provides a low cost, effective and feasible

  11. Radiological results for samples collected on paired glass- and cellulose-fiber filters at the Sandia complex, Tonopah Test Range, Nevada

    International Nuclear Information System (INIS)

    Mizell, Steve A.; Shadel, Craig A.

    2016-01-01

    Airborne particulates are collected at U.S. Department of Energy sites that exhibit radiological contamination on the soil surface to help assess the potential for wind to transport radionuclides from the contamination sites. Collecting these samples was originally accomplished by drawing air through a cellulose-fiber filter. These filters were replaced with glass-fiber filters in March 2011. Airborne particulates were collected side by side on the two filter materials between May 2013 and May 2014. Comparisons of the sample mass and the radioactivity determinations for the side-by-side samples were undertaken to determine if the change in the filter medium produced significant results. The differences in the results obtained using the two filter types were assessed visually by evaluating the time series and correlation plots and statistically by conducting a nonparametric matched-pair sign test. Generally, the glass-fiber filters collect larger samples of particulates and produce higher radioactivity values for the gross alpha, gross beta, and gamma spectroscopy analyses. However, the correlation between the radioanalytical results for the glass-fiber filters and the cellulose-fiber filters was not strong enough to generate a linear regression function to estimate the glass-fiber filter sample results from the cellulose-fiber filter sample results.

  12. Macroinvertebrate and algal community sample collection methods and data collected at selected sites in the Eagle River watershed, Colorado, 2000-07

    Science.gov (United States)

    Zuellig, Robert E.; Bruce, James F.

    2010-01-01

    State and local agencies are concerned about the effects of increasing urban development and human population growth on water quality and the biological condition of regional streams in the Eagle River watershed. In response to these needs, the U.S. Geological Survey initiated a study in cooperation with the Colorado River Water Conservation District, Eagle County, Eagle River Water and Sanitation District, Upper Eagle Regional Water Authority, Colorado Department of Transportation, City of Aurora, Town of Eagle, Town of Gypsum, Town of Minturn, Town of Vail, Vail Resorts, Colorado Springs Utilities, Denver Water, and the U.S. Department of Agriculture Forest Service. As part of this study, previously collected macroinvertebrate and algal data from the Eagle River watershed were compiled. This report includes macroinvertebrate data collected by the U.S. Geological Survey and(or) the U.S. Department of Agriculture Forest Service from 73 sites from 2000 to 2007 and algal data collected from up to 26 sites between 2000 and 2001 in the Eagle River watershed. Additionally, a brief description of the sample collection methods and data processing procedures are presented.

  13. Comparison of Techniques for Sampling Adult Necrophilous Insects From Pig Carcasses.

    Science.gov (United States)

    Cruise, Angela; Hatano, Eduardo; Watson, David W; Schal, Coby

    2018-02-06

    Studies of the pre-colonization interval and mechanisms driving necrophilous insect ecological succession depend on effective sampling of adult insects and knowledge of their diel and successional activity patterns. The number of insects trapped, their diversity, and diel periodicity were compared with four sampling methods on neonate pigs. Sampling method, time of day and decomposition age of the pigs significantly affected the number of insects sampled from pigs. We also found significant interactions of sampling method and decomposition day, time of sampling and decomposition day. No single method was superior to the other methods during all three decomposition days. Sampling times after noon yielded the largest samples during the first 2 d of decomposition. On day 3 of decomposition however, all sampling times were equally effective. Therefore, to maximize insect collections from neonate pigs, the method used to sample must vary by decomposition day. The suction trap collected the most species-rich samples, but sticky trap samples were the most diverse, when both species richness and evenness were factored into a Shannon diversity index. Repeated sampling during the noon to 18:00 hours period was most effective to obtain the maximum diversity of trapped insects. The integration of multiple sampling techniques would most effectively sample the necrophilous insect community. However, because all four tested methods were deficient at sampling beetle species, future work should focus on optimizing the most promising methods, alone or in combinations, and incorporate hand-collections of beetles. © The Author(s) 2018. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. Acceptability and usability of self-collected sampling for HPV testing among African-American women living in the Mississippi Delta.

    Science.gov (United States)

    Scarinci, Isabel C; Litton, Allison G; Garcés-Palacio, Isabel C; Partridge, Edward E; Castle, Philip E

    2013-01-01

    Human papillomavirus (HPV) DNA testing has been shown to be an effective approach to cervical cancer screening, and self-collection sampling for HPV testing could be a potential alternative to Pap test, provided that women who tested positive by any method get timely follow-up and care. This feasibility study examined acceptability and usability of self-collected sampling for HPV testing among African-American (AA) women in the Mississippi Delta to inform the development of interventions to promote cervical cancer screening in this population. The study consisted of two phases. Phase I consisted of eight focus groups (n = 87) with AA women to explore knowledge, attitudes, and beliefs about cervical cancer and HPV infection as well as acceptability of self-collected sampling for HPV testing. In phase II, we examined the usability of this technology through one discussion group (n = 9). The Health Belief Model guided data collection and analysis. Although participants perceived themselves as susceptible to cervical cancer and acknowledged its severity, there was a lack of knowledge of the link between HPV and cervical cancer, and they expressed a number of misconceptions. The most frequent barriers to screening included embarrassment, discomfort, and fear of the results. Women in both phases were receptive to self-collected sampling for HPV testing. All participants in the usability phase expressed that self-collection was easy and they did not experience any difficulties. Self-collection for HPV testing is an acceptable and feasible method among AA women in the Mississippi Delta to complement current cytology cervical cancer screening programs. Copyright © 2013 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  15. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false OTC test sample collection systems for drugs of abuse testing. 864.3260 Section 864.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology...

  16. Determination of 36Cl in environmental samples collected in the JCO by AMS

    International Nuclear Information System (INIS)

    Seki, R.; Tsukuba Univ., Ibaraki; Arai, D.; Nagashima, Y.; Takahashi, T.; Matsuhiro, T.; Imanaka, T.

    2003-01-01

    Long-lived chlorine, 36 Cl (T 1/2 = 301,000 y) in environmental samples has been measured by the AMS system installed in Tandem Accelerator Center, University of Tsukuba. A tri-carbon-molecular 12 C 3 - pilot beam method is used to stabilize the terminal voltage of the tandem. A small amount of pure carbon graphite is well mixed into a AgCl target material for creating Cl - and 12 C 3 - in the ion source. A 36 S isobaric interference in the system is eliminated to determine 36 Cl in environmental samples by chemical procedure. Some samples containing chlorine such as soil, chemical reagents and table salt have been collected in the JCO criticality accident site and analyzed to detect neutron-induced 36 Cl. The experimental result has been compared with a theoretical calculation. (author)

  17. Estimation of uranium in drinking water samples collected from different locations across Tarapur, India

    International Nuclear Information System (INIS)

    Dusane, C.B.; Maity, Sukanta; Sahu, S.K.; Pandit, G.G.

    2015-01-01

    In this study, drinking water samples were collected from different locations across Tarapur, India for screening uranium contents. Uranium concentrations were determined by differential pulse adsorptive stripping voltammetry (DPASV). Uranium concentration in water samples varied in a wide range from 0.6-7.9 μg L -1 . Results were compared with the international water quality guidelines World Health Organization (WHO, 2011) and were found within the permissible limit. Results were also compared with the safe limit values for drinking water recommended by national organization like Atomic Energy Regulatory Board (AERB). (author)

  18. Cerebral palsy in eastern Denmark: declining birth prevalence but increasing numbers of unilateral cerebral palsy in birth year period 1986-1998

    DEFF Research Database (Denmark)

    Ravn, Susanne Holst; Flachs, Esben Meulengracht; Uldall, Peter

    2010-01-01

    The Cerebral Palsy Registry in eastern Denmark has been collecting cases using a uniform data sampling procedure since birth year 1979. Children are included by two child neurologists and an obstetrician. Information on pregnancy, birth, neonatal period, impairments and demographic data are regis......The Cerebral Palsy Registry in eastern Denmark has been collecting cases using a uniform data sampling procedure since birth year 1979. Children are included by two child neurologists and an obstetrician. Information on pregnancy, birth, neonatal period, impairments and demographic data...

  19. Susceptibility to antifungal agents of Candida spp. from blood and feces collected in Novi Sad in 3-year period (2008-2010

    Directory of Open Access Journals (Sweden)

    Jelesić Zora Z.

    2011-01-01

    Full Text Available Candidemia is an important emerging nosocomial infection in patients with risk factors. Candida species from nonsterile sites can give insight into the characteristics of strains that may cause invasive disease. The aim of this study was to evaluate antifungal susceptibility of Candida blood and fecal isolates in Novi Sad, Vojvodina. During a 3-year period (2008 to 2010, 424 isolates of Candida spp. were collected, 30 bloodstream isolates and 394 strains from fecal samples. In vitro susceptibility of these isolates to five antifungal agents was established using commercial ATB FUNGUS 3 (Bio-Mérieux. Predominant species was Candida albicans (6 isolates from blood and 269 from feces. Resistance to one or more antifungal agents was less common in Candida albicans (3.63% than in other species (24.83%. Resistance to itraconazole was the most commonly found in both groups of isolates, 9.64% strains from feces and 20% from blood samples. Twelve isolates were multiply resistant, usually to fluconazole, itraconazole, and voriconazole. Resistance to amphotericine B was extremely rare. Although resistance to antimycotics of Candida spp. is rare at present, continued surveillance of antifungal susceptibility is necessary in order to monitor trends, and to choose the right empiric therapy.

  20. Use of a dry-plasma collection device to overcome problems with storage and transportation of blood samples for epidemiology studies in developing countries.

    Science.gov (United States)

    Nurgalieva, Z Z; Almuchambetova, R; Machmudova, A; Kapsultanova, D; Osato, M S; Peacock, J; Zoltek, R P; Marchildon, P A; Graham, D Y; Zhangabylov, A

    2000-11-01

    Studies are difficult in areas lacking modern facilities due to the inability to reliably collect, store, and ship samples. Thus, we sought to evaluate the use of a dry plasma collection device for seroepidemiology studies. Plasma was obtained by fingerstick using a commercial dry plasma collection device (Chemcard Plasma Collection Device) and serum (venipuncture) from individuals in Kazakhstan. Plasma samples were air dried for 15 min and then stored desiccated in foil zip-lock pouches at 4 to 6 degrees C and subsequently shipped to the United States by air at ambient temperature. Serum samples remained frozen at -20 degrees C until assayed. Helicobacter pylori status was determined by enzyme-linked immunosorbent assay (HM-CAP EIA) for the dry plasma and the serum samples. The results were concordant in 250 of the 289 cases (86.5%). In 25 cases (8.6%), the dry plasma samples gave indeterminate results and could not be retested because only one sample was collected. Five serum samples were positive, and the corresponding dry plasma samples were negative; one serum sample was negative, and the corresponding plasma sample was positive. The relative sensitivity and specificity of the Chemcard samples to serum were 97.6 and 97.9%, respectively, excluding those with indeterminate results. Repeated freeze-thawing had no adverse effect on the accuracy of the test. We found the dry plasma collection device to provide an accurate and practical alternative to serum when venipuncture may be difficult or inconvenient and sample storage and handling present difficulties, especially for seroepidemiologic studies in rural areas or developing countries and where freeze-thawing may be unavoidable.

  1. Vapor space characterization of waste tank 241-C-101: Results from samples collected on 9/1/94

    International Nuclear Information System (INIS)

    Lucke, R.B.; Clauss, T.W.; Ligotke, M.W.

    1995-11-01

    This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-C-101 (referred to as Tank C-101) and the ambient air collected - 30 ft upwind near the tank and through the VSS near the tank. Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The sample job was designated S4056, and samples were collected by WHC on September 1, 1994, using the vapor sampling system (VSS). The samples were inspected upon delivery to the 326/23B laboratory and logged into PNL record book 55408 before implementation of PNL Technical Procedure PNL-TVP-07. Custody of the sorbent traps was transferred to PNL personnel performing the inorganic analysis and stored at refrigerated (≤ 10 degrees C) temperature until the time of analysis. The canisters were stored in the 326/23B laboratory at ambient (25 degrees C) temperature until the time of the analysis. Access to the 326/23B laboratory is limited to PNL personnel working on the waste-tank safety program. Analyses described in this report were performed at PNL in the 300 area of the Hanford Reservation. Analytical methods that were used are described in the text. In summary, sorbent traps for inorganic analyses containing sample materials were either weighed (for water analysis) or desorbed with the appropriate aqueous solutions (for NH 3 , NO 2 , and NO analyses). The aqueous extracts were analyzed either by selective electrode or by ion chromatography (IC). Organic analyses were performed using cryogenic preconcentration followed by gas chromatography/mass spectrometry (GC/MS)

  2. Challenges in collecting clinical samples for research from pregnant women of South Asian origin: evidence from a UK study.

    Science.gov (United States)

    Neelotpol, Sharmind; Hay, Alastair W M; Jolly, A Jim; Woolridge, Mike W

    2016-08-31

    To recruit South Asian pregnant women, living in the UK, into a clinicoepidemiological study for the collection of lifestyle survey data and antenatal blood and to retain the women for the later collection of cord blood and meconium samples from their babies for biochemical analysis. A longitudinal study recruiting pregnant women of South Asian and Caucasian origin living in the UK. Recruitment of the participants, collection of clinical samples and survey data took place at the 2 sites within a single UK Northern Hospital Trust. Pregnant women of South Asian origin (study group, n=98) and of Caucasian origin (comparison group, n=38) living in Leeds, UK. Among the participants approached, 81% agreed to take part in the study while a 'direct approach' method was followed. The retention rate of the participants was a remarkable 93.4%. The main challenges in recruiting the ethnic minority participants were their cultural and religious conservativeness, language barrier, lack of interest and feeling of extra 'stress' in taking part in research. The chief investigator developed an innovative participant retention method, associated with the women's cultural and religious practices. The method proved useful in retaining the participants for about 5 months and in enabling successful collection of clinical samples from the same mother-baby pairs. The collection of clinical samples and lifestyle data exceeded the calculated sample size required to give the study sufficient power. The numbers of samples obtained were: maternal blood (n=171), cord blood (n=38), meconium (n=176), lifestyle questionnaire data (n=136) and postnatal records (n=136). Recruitment and retention of participants, according to the calculated sample size, ensured sufficient power and success for a clinicoepidemiological study. Results suggest that development of trust and confidence between the participant and the researcher is the key to the success of a clinical and epidemiological study involving

  3. Bridging the gap between sample collection and laboratory analysis: using dried blood spots to identify human exposure to chemical agents

    Science.gov (United States)

    Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.

    2016-05-01

    Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.

  4. Influence of sexual stimulation on sperm parameters in semen samples collected via masturbation from normozoospermic men or cryptozoospermic men participating in an assisted reproduction programme.

    Science.gov (United States)

    Yamamoto, Y; Sofikitis, N; Mio, Y; Miyagawa, I

    2000-05-01

    To evaluate the influence of sexual stimulation via sexually stimulating videotaped visual images (VIM) on sperm function, two semen samples were collected from each of 19 normozoospermic men via masturbation with VIM. Two additional samples were collected from each man via masturbation without VIM. The volume of seminal plasma, total sperm count, sperm motility, percentage of morphologically normal spermatozoa, outcome of hypo-osmotic swelling test and zona-free hamster oocyte sperm penetration assay, and markers of the secretory function of prostate were significantly larger in semen samples collected via masturbation with VIM than masturbation without VIM. The improved sperm parameters in the samples collected via masturbation with VIM may reflect an enhanced prostatic secretory function and increased loading of the vas deferens at that time. In a similar protocol, two semen samples were collected via masturbation with VIM from each of 22 non-obstructed azoospermic men. Semen samples from these men had been occasionally positive in the past for a very small number of spermatozoa (cryptozoospermic men). Two additional samples were collected from each cryptozoospermic man via masturbation without VIM. The volume of seminal plasma, total sperm count, sperm motility, and a marker of the secretory function of prostate were significantly larger in semen samples collected via masturbation with VIM. Fourteen out of the 22 men were negative for spermatozoa in both samples collected via masturbation without VIM. These men demonstrated spermatozoa in both samples collected via masturbation with VIM. Six men with immotile spermatozoa in both samples collected via masturbation without VIM exposed motile spermatozoa in both samples collected via masturbation with VIM. High sexual stimulation during masturbation with VIM results in recovery of spermatozoa of greater fertilizing potential both in normozoospermic and cryptozoospermic men. The appearance of spermatozoa after

  5. A simple air sampling technique for monitoring nitrous oxide pollution

    Energy Technology Data Exchange (ETDEWEB)

    Austin, J C; Shaw, R; Moyes, D; Cleaton-Jones, P E

    1981-01-01

    A simple, inexpensive device for the continuous low-flow sampling of air was devised to permit monitoring of pollution by gaseous anaesthetics. The device consisted of a water-filled Perspex cylinder in which a double-walled flexible-film gas sample collection bag was suspended. Air samples could be aspirated into the collection bag at flow rates of as low as 1 ml min-1 by allowing the water to drain from the cylinder at a controlled rate. The maintenance of sample integrity with aspiration and storage of samples of nitrous oxide in air at concentrations of 1000, 100 and 30 p.p.m. v/v was examined using gas chromatography. The sample bags retained a mean 94% of the nitrous oxide in air samples containing nitrous oxide 25 p.p.m. over a 72-h storage period.

  6. Demonstration Exercise of a Validated Sample Collection Method for Powders Suspected of Being Biological Agents in Georgia 2006

    International Nuclear Information System (INIS)

    Marsh, B.

    2007-01-01

    August 7, 2006 the state of Georgia conducted a collaborative sampling exercise between the Georgia National Guard 4th Civil Support Team Weapons of Mass Destruction (CST-WMD) and the Georgia Department of Human Resources Division of Public Health demonstrating a recently validated bulk powder sampling method. The exercise was hosted at the Federal Law Enforcement Training Center (FLETC) at Glynn County, Georgia and involved the participation of the Georgia Emergency Management Agency (GEMA), Georgia National Guard, Georgia Public Health Laboratories, the Federal Bureau of Investigation Atlanta Office, Georgia Coastal Health District, and the Glynn County Fire Department. The purpose of the exercise was to demonstrate a recently validated national sampling standard developed by the American Standards and Test Measures (ASTM) International; ASTM E2458 S tandard Practice for Bulk Sample Collection and Swab Sample Collection of Visible Powders Suspected of Being Biological Agents from Nonporous Surfaces . The intent of the exercise was not to endorse the sampling method, but to develop a model for exercising new sampling methods in the context of existing standard operating procedures (SOPs) while strengthening operational relationships between response teams and analytical laboratories. The exercise required a sampling team to respond real-time to an incident cross state involving a clandestine bio-terrorism production lab found within a recreational vehicle (RV). Sample targets consisted of non-viable gamma irradiated B. anthracis Sterne spores prepared by Dugway Proving Ground. Various spore concentration levels were collected by the ASTM method, followed by on- and off-scene analysis utilizing the Center for Disease Control (CDC) Laboratory Response Network (LRN) and National Guard Bureau (NGB) CST mobile Analytical Laboratory Suite (ALS) protocols. Analytical results were compared and detailed surveys of participant evaluation comments were examined. I will

  7. Sensor-triggered sampling to determine instantaneous airborne vapor exposure concentrations.

    Science.gov (United States)

    Smith, Philip A; Simmons, Michael K; Toone, Phillip

    2018-06-01

    It is difficult to measure transient airborne exposure peaks by means of integrated sampling for organic chemical vapors, even with very short-duration sampling. Selection of an appropriate time to measure an exposure peak through integrated sampling is problematic, and short-duration time-weighted average (TWA) values obtained with integrated sampling are not likely to accurately determine actual peak concentrations attained when concentrations fluctuate rapidly. Laboratory analysis for integrated exposure samples is preferred from a certainty standpoint over results derived in the field from a sensor, as a sensor user typically must overcome specificity issues and a number of potential interfering factors to obtain similarly reliable data. However, sensors are currently needed to measure intra-exposure period concentration variations (i.e., exposure peaks). In this article, the digitized signal from a photoionization detector (PID) sensor triggered collection of whole-air samples when toluene or trichloroethylene vapors attained pre-determined levels in a laboratory atmosphere generation system. Analysis by gas chromatography-mass spectrometry of whole-air samples (with both 37 and 80% relative humidity) collected using the triggering mechanism with rapidly increasing vapor concentrations showed good agreement with the triggering set point values. Whole-air samples (80% relative humidity) in canisters demonstrated acceptable 17-day storage recoveries, and acceptable precision and bias were obtained. The ability to determine exceedance of a ceiling or peak exposure standard by laboratory analysis of an instantaneously collected sample, and to simultaneously provide a calibration point to verify the correct operation of a sensor was demonstrated. This latter detail may increase the confidence in reliability of sensor data obtained across an entire exposure period.

  8. Concentration comparison of selected constituents between groundwater samples collected within the Missouri River alluvial aquifer using purge and pump and grab-sampling methods, near the city of Independence, Missouri, 2013

    Science.gov (United States)

    Krempa, Heather M.

    2015-10-29

    The U.S. Geological Survey, in cooperation with the City of Independence, Missouri, Water Department, has historically collected water-quality samples using the purge and pump method (hereafter referred to as pump method) to identify potential contamination in groundwater supply wells within the Independence well field. If grab sample results are comparable to the pump method, grab samplers may reduce time, labor, and overall cost. This study was designed to compare constituent concentrations between samples collected within the Independence well field using the pump method and the grab method.

  9. CO2 isotope analyses using large air samples collected on intercontinental flights by the CARIBIC Boeing 767

    NARCIS (Netherlands)

    Assonov, S.S.; Brenninkmeijer, C.A.M.; Koeppel, C.; Röckmann, T.

    2009-01-01

    Analytical details for 13C and 18O isotope analyses of atmospheric CO2 in large air samples are given. The large air samples of nominally 300 L were collected during the passenger aircraft-based atmospheric chemistry research project CARIBIC and analyzed for a large number of trace gases and

  10. Comparison of vapor sampling system (VSS) and in situ vapor sampling (ISVS) methods on Tanks C-107, BY-108, and S-102. Revision 1

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Edwards, J.A.; Evans, J.C.

    1996-08-01

    This report discusses comparison tests for two methods of collecting vapor samples from the Hanford Site high-level radioactive waste tank headspaces. The two sampling methods compared are the truck-mounted vapor sampling system (VSS) and the cart-mounted in-situ vapor sampling (ISVS). Three tanks were sampled by both the VSS and ISVS methods from the same access risers within the same 8-hour period. These tanks have diverse headspace compositions and they represent the highest known level of several key vapor analytes

  11. Development of a multiplex real-time PCR assay for detection of human enteric viruses other than norovirus using samples collected from gastroenteritis patients in Fukui Prefecture, Japan.

    Science.gov (United States)

    Kowada, Kazuaki; Takeuchi, Kenji; Hirano, Eiko; Toho, Miho; Sada, Kiyonao

    2018-01-01

    There are many varieties of gastroenteritis viruses, of which norovirus (NoV) accounts for over 90% of the viral food poisoning incidents in Japan. However, protocols for rapidly identifying other gastroenteritis viruses need to be established to investigate NoV-negative cases intensively. In this study, a multiplex real-time PCR assay targeting rotavirus A, rotavirus C, sapovirus, astrovirus, adenovirus, and enterovirus was developed using stool samples collected from gastroenteritis patients between 2010 and 2013 in Fukui Prefecture, Japan. Of the 126 samples collected sporadically from pediatric patients with suspected infectious gastroenteritis, 51 were positive for non-NoV target viruses, whereas 27 were positive for NoV, showing a high prevalence of non-NoV viruses in pediatric patients. In contrast, testing in 382 samples of 58 gastroenteritis outbreaks showed that non-NoV viruses were detected in 13 samples, with NoV in 267. Of the 267 NoV-positive patients, only two were co-infected with non-NoV target viruses, suggesting that testing for non-NoV gastroenteritis viruses in NoV-positive samples was mostly unnecessary in outbreak investigations. Given these results, multiplex real-time PCR testing for non-NoV gastroenteritis viruses, conducted separately from NoV testing, may be helpful to deal with two types of epidemiological investigations, regular surveillance of infectious gastroenteritis and urgent testing when gastroenteritis outbreaks occur. © 2017 Wiley Periodicals, Inc.

  12. Assessment of high-risk human papillomavirus infections using clinician- and self-collected cervical sampling methods in rural women from far western Nepal.

    Directory of Open Access Journals (Sweden)

    Derek C Johnson

    Full Text Available Nepal has one of the highest cervical cancer rates in South Asia. Only a few studies in populations from urban areas have investigated type specific distribution of human papillomavirus (HPV in Nepali women. Data on high-risk HPV (HR-HPV types are not currently available for rural populations in Nepal. We aimed to assess the distribution of HR- HPV among rural Nepali women while assessing self-collected and clinician-collected cervico-vaginal specimens as sample collection methods for HPV screening.Study participants were recruited during a health camp conducted by Nepal Fertility Care Center in Achham District of rural far western Nepal. Women of reproductive age completed a socio-demographic and clinical questionnaire, and provided two specimens; one cervical-vaginal specimen using a self-collection method and another cervical specimen collected by health camp auxiliary nurse midwives during a pelvic examination. All samples were tested for 14 different HR-HPV mRNA and also specific for HPV16/18/45 mRNA.Of 261 women with both clinician- and self-collected cervical samples, 25 tested positive for HR-HPV, resulting in an overall HR-HPV prevalence of 9.6% (95% confidence Interval [CI]: 6.3-13.8. The overall Kappa value assessing agreement between clinician- and self-collected tests was 0.62 (95% CI: 0.43-0.81, indicating a "good" level of agreement. Abnormal cytology was reported for 8 women. One woman identified with squamous cell carcinoma (SCC, and 7 women with high grade squamous intraepithelial lesions (HSIL. Seven of the 8 women tested positive for HR-HPV (87.5% in clinician-collected samples and 6 in self-collected samples (75.0%.This is the first study to assess HR-HPV among rural Nepali women. Self-collected sampling methods should be the subject of additional research in Nepal for screening HR-HPV, associated with pre-cancer lesions and cancer, in women in rural areas with limited access to health services.

  13. Composition and source apportionment of fine particulate matter during extended calm periods in the city of Rijeka, Croatia

    Science.gov (United States)

    Ivošević, T.; Orlić, I.; Bogdanović Radović, I.; Čargonja, M.; Stelcer, E.

    2017-09-01

    In the city of Rijeka, Croatia, an extended, two-year aerosol pollution monitoring campaign was recently completed. During that period, 345 samples of fine fraction of aerosols were collected on stretched Teflon filters. All samples were analyzed by Ion Beam Analysis techniques Proton Induced X-ray Emission and Proton Induced γ-Ray Emission and concentrations of 22 elements were determined. Concentrations of black carbon were determined by Laser Integrated Plate Method. For the Bay of Kvarner, where the city of Rijeka is located, long periods of calm weather are common. As a consequence, during these periods, air pollution is steadily increasing. To pin-point and characterize local, mostly anthropogenic, air pollution sources, only samples collected during the extended calm periods were used in this work. As a cut-off wind speed, speed of 1.5 m/s was used. In that way, out of all 345 samples, only 188 were selected. Those samples were statistically evaluated by means of positive matrix factorization. Results show that from all anthropogenic sources (vehicles, secondary sulphates, smoke, heavy oil combustion, road dust, industry Fe and port activities) only secondary sulphates and heavy oil combustion were significantly higher (40% and 50%, respectively) during calm periods. On the other hand, natural components of aerosol pollution such as soil and sea salts, (typically present in concentrations of 1.4% and 9%, respectively) are practically non-existent for calm weather conditions.

  14. X RF measurement for sediment sample collected from the niles in Khartoum State

    International Nuclear Information System (INIS)

    Mohammed, Aisha Abdelgader Ahmed

    2015-04-01

    The goal of this study to determine the concentration of element (K, Ca Ti, Mn, Fe, Cu, Zn, Pb, Rb, Sr, Y and Zr) in sediment sample collected from thirty different sites from the three rivers in Khartoum state. X-ray fluorescence (X RF) was used to identify the element concentration. Validation of the equipment was done by measuring reference samples provided by IAEA. Iron was found to be the dominant element with concentration ranged between (13000 ppm) in the white nile to (101000 ppm) in the blue nile, Pb was found to be the lowest among the twelve elements measured with concentration ranged between (11.7 ppm) in the white nile to (28 ppm) in the river nile for all samples. In general there was no variation of the concentration of elements between the blue nile sediments and the river nile sediments and was found variation of concentration of elements between the white nile sediments and other two niles. (Author).

  15. Pre-Mission Input Requirements to Enable Successful Sample Collection by a Remote Field/EVA Team

    Science.gov (United States)

    Cohen, B. A.; Young, K. E.; Lim, D. S.

    2015-01-01

    This paper is intended to evaluate the sample collection process with respect to sample characterization and decision making. In some cases, it may be sufficient to know whether a given outcrop or hand sample is the same as or different from previous sampling localities or samples. In other cases, it may be important to have more in-depth characterization of the sample, such as basic composition, mineralogy, and petrology, in order to effectively identify the best sample. Contextual field observations, in situ/handheld analysis, and backroom evaluation may all play a role in understanding field lithologies and their importance for return. For example, whether a rock is a breccia or a clast-laden impact melt may be difficult based on a single sample, but becomes clear as exploration of a field site puts it into context. The FINESSE (Field Investigations to Enable Solar System Science and Exploration) team is a new activity focused on a science and exploration field based research program aimed at generating strategic knowledge in preparation for the human and robotic exploration of the Moon, near-Earth asteroids (NEAs) and Phobos and Deimos. We used the FINESSE field excursion to the West Clearwater Lake Impact structure (WCIS) as an opportunity to test factors related to sampling decisions. In contract to other technology-driven NASA analog studies, The FINESSE WCIS activity is science-focused, and moreover, is sampling-focused, with the explicit intent to return the best samples for geochronology studies in the laboratory. This specific objective effectively reduces the number of variables in the goals of the field test and enables a more controlled investigation of the role of the crewmember in selecting samples. We formulated one hypothesis to test: that providing details regarding the analytical fate of the samples (e.g. geochronology, XRF/XRD, etc.) to the crew prior to their traverse will result in samples that are more likely to meet specific analytical

  16. Feasibility of self-sampled dried blood spot and saliva samples sent by mail in a population-based study

    International Nuclear Information System (INIS)

    Sakhi, Amrit Kaur; Bastani, Nasser Ezzatkhah; Ellingjord-Dale, Merete; Gundersen, Thomas Erik; Blomhoff, Rune; Ursin, Giske

    2015-01-01

    In large epidemiological studies it is often challenging to obtain biological samples. Self-sampling by study participants using dried blood spots (DBS) technique has been suggested to overcome this challenge. DBS is a type of biosampling where blood samples are obtained by a finger-prick lancet, blotted and dried on filter paper. However, the feasibility and efficacy of collecting DBS samples from study participants in large-scale epidemiological studies is not known. The aim of the present study was to test the feasibility and response rate of collecting self-sampled DBS and saliva samples in a population–based study of women above 50 years of age. We determined response proportions, number of phone calls to the study center with questions about sampling, and quality of the DBS. We recruited women through a study conducted within the Norwegian Breast Cancer Screening Program. Invitations, instructions and materials were sent to 4,597 women. The data collection took place over a 3 month period in the spring of 2009. Response proportions for the collection of DBS and saliva samples were 71.0% (3,263) and 70.9% (3,258), respectively. We received 312 phone calls (7% of the 4,597 women) with questions regarding sampling. Of the 3,263 individuals that returned DBS cards, 3,038 (93.1%) had been packaged and shipped according to instructions. A total of 3,032 DBS samples were sufficient for at least one biomarker analysis (i.e. 92.9% of DBS samples received by the laboratory). 2,418 (74.1%) of the DBS cards received by the laboratory were filled with blood according to the instructions (i.e. 10 completely filled spots with up to 7 punches per spot for up to 70 separate analyses). To assess the quality of the samples, we selected and measured two biomarkers (carotenoids and vitamin D). The biomarker levels were consistent with previous reports. Collecting self-sampled DBS and saliva samples through the postal services provides a low cost, effective and feasible

  17. POLYCYCLIC AROMATIC HYDROCARBON CONTAMINATION LEVELS IN COLLECTED SAMPLES FROM VICINITY OF A HIGHWAY

    Directory of Open Access Journals (Sweden)

    S. V. Samimi ، R. Akbari Rad ، F. Ghanizadeh

    2009-01-01

    Full Text Available Tehran as the biggest city of Iran with a population of more than 10 millions has potentially high pollutant exposures of gas oil and gasoline combustion from vehicles that are commuting in the highways every day. The vehicle exhausts contain polycyclic aromatic hydrocarbons, which are produced by incomplete combustion and can be directly deposited in the environment. In the present study, the presence of polycyclic aromatic hydrocarbons contamination in the collected samples of a western highway in Tehran was investigated. The studied location was a busy highway in Tehran. High performance liquid chromatography equipped with florescence detector was used for determination of polycyclic aromatic hydrocarbons concentrations in the studied samples. Total concentration of the ten studied polycyclic aromatic hydrocarbons compounds ranged from 11107 to 24342 ng/g dry weight in the dust samples and increased from 164 to 2886 ng/g dry weight in the soil samples taken from 300 m and middle of the highway, respectively. Also the average of Σ PAHs was 1759 ng/L in the water samples of pools in parks near the highway. The obtained results indicated that polycyclic aromatic hydrocarbons contamination levels were very high in the vicinity of the highway.

  18. Elemental analysis of size-fractionated particulate matter sampled in Goeteborg, Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Annemarie [Department of Chemistry, Atmospheric Science, Goeteborg University, SE-412 96 Goeteborg (Sweden)], E-mail: wagnera@chalmers.se; Boman, Johan [Department of Chemistry, Atmospheric Science, Goeteborg University, SE-412 96 Goeteborg (Sweden); Gatari, Michael J. [Institute of Nuclear Science and Technology, University of Nairobi, P.O. Box 30197-00100, Nairobi (Kenya)

    2008-12-15

    The aim of the study was to investigate the mass distribution of trace elements in aerosol samples collected in the urban area of Goeteborg, Sweden, with special focus on the impact of different air masses and anthropogenic activities. Three measurement campaigns were conducted during December 2006 and January 2007. A PIXE cascade impactor was used to collect particulate matter in 9 size fractions ranging from 16 to 0.06 {mu}m aerodynamic diameter. Polished quartz carriers were chosen as collection substrates for the subsequent direct analysis by TXRF. To investigate the sources of the analyzed air masses, backward trajectories were calculated. Our results showed that diurnal sampling was sufficient to investigate the mass distribution for Br, Ca, Cl, Cu, Fe, K, Sr and Zn, whereas a 5-day sampling period resulted in additional information on mass distribution for Cr and S. Unimodal mass distributions were found in the study area for the elements Ca, Cl, Fe and Zn, whereas the distributions for Br, Cu, Cr, K, Ni and S were bimodal, indicating high temperature processes as source of the submicron particle components. The measurement period including the New Year firework activities showed both an extensive increase in concentrations as well as a shift to the submicron range for K and Sr, elements that are typically found in fireworks. Further research is required to validate the quantification of trace elements directly collected on sample carriers.

  19. Elemental analysis of size-fractionated particulate matter sampled in Goeteborg, Sweden

    International Nuclear Information System (INIS)

    Wagner, Annemarie; Boman, Johan; Gatari, Michael J.

    2008-01-01

    The aim of the study was to investigate the mass distribution of trace elements in aerosol samples collected in the urban area of Goeteborg, Sweden, with special focus on the impact of different air masses and anthropogenic activities. Three measurement campaigns were conducted during December 2006 and January 2007. A PIXE cascade impactor was used to collect particulate matter in 9 size fractions ranging from 16 to 0.06 μm aerodynamic diameter. Polished quartz carriers were chosen as collection substrates for the subsequent direct analysis by TXRF. To investigate the sources of the analyzed air masses, backward trajectories were calculated. Our results showed that diurnal sampling was sufficient to investigate the mass distribution for Br, Ca, Cl, Cu, Fe, K, Sr and Zn, whereas a 5-day sampling period resulted in additional information on mass distribution for Cr and S. Unimodal mass distributions were found in the study area for the elements Ca, Cl, Fe and Zn, whereas the distributions for Br, Cu, Cr, K, Ni and S were bimodal, indicating high temperature processes as source of the submicron particle components. The measurement period including the New Year firework activities showed both an extensive increase in concentrations as well as a shift to the submicron range for K and Sr, elements that are typically found in fireworks. Further research is required to validate the quantification of trace elements directly collected on sample carriers

  20. Urine concentrations of oral salbutamol in samples collected after intense exercise in endurance athletes

    DEFF Research Database (Denmark)

    Hostrup, Morten; Kalsen, Anders; Auchenberg, Michael

    2014-01-01

    Our objective was to investigate urine concentrations of 8 mg oral salbutamol in samples collected after intense exercise in endurance athletes. Nine male endurance athletes with a VO2max of 70.2 ± 5.9 mL/min/kg (mean ± SD) took part in the study. Two hours after administration of 8 mg oral...

  1. Evaluation of Trapper-Collected Nobuto Filter-Paper Blood Samples for Distemper and Parvovirus Antibody Detection in Coyotes (Canis latrans) and Raccoons (Procyon lotor).

    Science.gov (United States)

    Kamps, Amanda J; Dubay, Shelli A; Langenberg, Julie; Maes, Roger K

    2015-07-01

    Blood samples are often collected from free-ranging wildlife for antibody detection. However, filter-paper (FP) strips are more cost efficient and easy to collect and store. We evaluated trapper-collected FP strips and body-cavity blood for canine distemper (CDV) and parvovirus (CPV-2) antibody detection in raccoons (Procyon lotor) and coyotes (Canis latrans). From 2008 to 2010, licensed trappers near Madison and Milwaukee, Wisconsin, US collected paired samples from harvested animals. Canine distemper antibodies were detected using virus neutralization and parvovirus antibodies were detected using hemagglutination inhibition. Titers ≥ 1:32 for CDV and ≥ 1:25 for CPV-2 were considered evidence of exposure. Using Cohen's kappa test of agreement, FP strip titers agreed with sera for CDV in coyotes (n = 28, K = 0.772) and raccoons (n = 29, K = 0.858) and for CPV-2 in coyotes (n = 40, K = 0.775) and raccoons (n = 70, K = 0.646). However, raccoons determined to be exposed to CPV-2 from sera were unexposed by FP strips in 35% of the samples. Titer results may be affected by quality and volume of blood samples, interval between collection and processing, small sample sizes, and diagnostic testing procedures. Filter-paper strips can be useful for detecting CDV and CPV-2 exposure in coyotes and raccoons with correct field sample collection and appropriate diagnostic testing procedures.

  2. Systematic Sampling and Cluster Sampling of Packet Delays

    OpenAIRE

    Lindh, Thomas

    2006-01-01

    Based on experiences of a traffic flow performance meter this papersuggests and evaluates cluster sampling and systematic sampling as methods toestimate average packet delays. Systematic sampling facilitates for exampletime analysis, frequency analysis and jitter measurements. Cluster samplingwith repeated trains of periodically spaced sampling units separated by randomstarting periods, and systematic sampling are evaluated with respect to accuracyand precision. Packet delay traces have been ...

  3. A simple passive method of collecting water vapour for environmental tritium monitoring

    International Nuclear Information System (INIS)

    Iida, T.; Fukuda, H.; Ikebe, Y.; Yokoyama, S.

    1995-01-01

    To investigate the average behaviour of tritium in an atmospheric environment, it is necessary to collect water vapour in air over a long period at numerous locations. For the purpose of the study, the passive method was developed: this is handy, low-priced and could collect water vapour in air without motive power. This paper describes the characteristics of the passive collecting method, the performance of water collection in outdoor air and the measurements of tritium concentrations in water samples collected by the passive method. (author)

  4. Racial and Ethnic Diversity in Academic Library Collections: Ownership and Access of African American and U.S. Latino Periodical Literature.

    Science.gov (United States)

    Vega Garcia, Susan A.

    2000-01-01

    Measures ownership of and access to African American and Latino periodical literature, illustrating the successes and failures in promoting racial and ethnic diversity in research libraries belonging to the ARL (Association of Research Libraries). Discusses desirability of multicultural collections; bibliographic control and access issues; and…

  5. Are symptom features of depression during pregnancy, the postpartum period and outside the peripartum period distinct? Results from a nationally representative sample using item response theory (IRT).

    Science.gov (United States)

    Hoertel, Nicolas; López, Saioa; Peyre, Hugo; Wall, Melanie M; González-Pinto, Ana; Limosin, Frédéric; Blanco, Carlos

    2015-02-01

    Whether there are systematic differences in depression symptom expression during pregnancy, the postpartum period and outside these periods (i.e., outside the peripartum period) remains debated. The aim of this study was to use methods based on item response theory (IRT) to examine, after equating for depression severity, differences in the likelihood of reporting DSM-IV symptoms of major depressive episode (MDE) in women of childbearing age (i.e., aged 18-50) during pregnancy, the postpartum period and outside the peripartum period. We conducted these analyses using a large, nationally representative sample of women of childbearing age from the United States (n = 11,256) who participated in the second wave of the National Epidemiologic Survey on Alcohol and Related Conditions (NESARC). The overall 12-month prevalence of all depressive criteria (except for worthlessness/guilt) was significantly lower in pregnant women than in women of childbearing age outside the peripartum period, whereas the prevalence of all symptoms (except for "psychomotor symptoms") was not significantly different between the postpartum and the nonperipartum group. There were no clinically significant differences in the endorsement rates of symptoms of MDE by pregnancy status when equating for levels of depression severity. This study suggests that the clinical presentation of depressive symptoms in women of childbearing age does not differ during pregnancy, the postpartum period and outside the peripartum period. These findings do not provide psychometric support for the inclusion of the peripartum onset specifier for major depressive disorder in the DSM-5. © 2014 Wiley Periodicals, Inc.

  6. Automated Sampling and Extraction of Krypton from Small Air Samples for Kr-85 Measurement Using Atom Trap Trace Analysis

    International Nuclear Information System (INIS)

    Hebel, S.; Hands, J.; Goering, F.; Kirchner, G.; Purtschert, R.

    2015-01-01

    Atom-Trap-Trace-Analysis (ATTA) provides the capability of measuring the Krypton-85 concentration in microlitre amounts of krypton extracted from air samples of about 1 litre. This sample size is sufficiently small to allow for a range of applications, including on-site spot sampling and continuous sampling over periods of several hours. All samples can be easily handled and transported to an off-site laboratory for ATTA measurement, or stored and analyzed on demand. Bayesian sampling methodologies can be applied by blending samples for bulk measurement and performing in-depth analysis as required. Prerequisite for measurement is the extraction of a pure krypton fraction from the sample. This paper introduces an extraction unit able to isolate the krypton in small ambient air samples with high speed, high efficiency and in a fully automated manner using a combination of cryogenic distillation and gas chromatography. Air samples are collected using an automated smart sampler developed in-house to achieve a constant sampling rate over adjustable time periods ranging from 5 minutes to 3 hours per sample. The smart sampler can be deployed in the field and operate on battery for one week to take up to 60 air samples. This high flexibility of sampling and the fast, robust sample preparation are a valuable tool for research and the application of Kr-85 measurements to novel Safeguards procedures. (author)

  7. A continuous flow from sample collection to data acceptability determination using an automated system

    International Nuclear Information System (INIS)

    Fisk, J.F.; Leasure, C.; Sauter, A.D.

    1993-01-01

    In its role as regulator, EPA is the recipient of enormous reams of analytical data, especially within the Superfund Program. In order to better manage the volume of paper that comes in daily, Superfund has required its laboratories to provide data that is contained on reporting forms to be delivered also on a diskette for uploading into data bases for various purposes, such as checking for contractual compliance, tracking quality assurance parameters, and, ultimately, for reviewing the data by computer. This last area, automated review of the data, has generated programs that are not necessarily appropriate for use by clients other than Superfund. Such is the case with Los Alamos National Laboratory's Environmental Chemistry Group and its emerging subcontractor community, designed to meet the needs of the remedial action program at LANL. LANL is in the process of implementing an automated system that will be used from the planning stage of sample collection to the production of a project-specific report on analytical data quality. Included are electronic scheduling and tracking of samples, data entry, checking and transmission, data assessment and qualification for use, and report generation that will tie the analytical data quality back to the performance criteria defined prior to sample collection. Industry standard products will be used (e.g., ORACLE, Microsoft Excel) to ensure support for users, prevent dependence on proprietary software, and to protect LANL's investment for the future

  8. Headspace vapor characterization of Hanford Waste Tank SX-102: Results from samples collected on July 19, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    McVeety, B.D.; Evans, J.C.; Clauss, T.W.; Pool, K.H.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-SX-102 (Tank SX-102) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed under the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5046. Samples were collected by WHC on July 19, 1995, using the vapor sampling system (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  9. Headspace vapor characterization of Hanford Waste Tank AX-103: Results from samples collected on June 21, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    Ligotke, M.W.; Pool, K.H.; Clauss, T.W.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-AX-103 (Tank AX-103) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5029. Samples were collected by WHC on June 21, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  10. Headspace vapor characterization of Hanford Waste Tank AX-101: Results from samples collected on June 15, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    Pool, K.H.; Clauss, T.W.; Evans, J.C.; McVeety, B.D.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-AX-101 (Tank AX-101) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) under the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5028. Samples were collected by WHC on June 15, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  11. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    Science.gov (United States)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  12. Assessment of indicators and collection methodology to estimate nutrient digestibility in buffaloes

    Directory of Open Access Journals (Sweden)

    Luciana Felizardo Pereira Soares

    2011-09-01

    Full Text Available Dry fecal matter production was estimated from neutral detergent indicators on indigestible fiber, indigestible acid detergent fiber, indigestible dry matter, incubated for 144 hours and 288 hours, as well as chromium oxide (Cr2O3 and enriched and purified isolated lignin (LIPE® in two sampling schemes (3 and 5 days on buffaloes. Sample consisted of five castrated animals with average weight of 300 ± 0.6 kg fed on elephant grass cv Cameroon (Pennisetum purpureum. Experimental design consisted of randomized blocks in subdivided plots. Production of dry fecal matter was overestimated when using Cr2O3, indigestible acid detergent fiber 144 hours, indigestible neutral detergent fiber 144 hours, indigestible neutral detergent fiber 288 hours and indigestible dry matter 144 hours, while indigestible acid detergent fiber 288 hours, indigestible dry matter 288 hours and LIPE® did not differ from total collection. The same result was observed for apparent digestibility of nutrients. There was no difference in dry fecal matter production and digestibility between both collection periods of 3 and 5 days, demonstrating that a collection period of three days can be used to estimate dry fecal matter production in buffaloes. A three-day period of sample collection, in order to estimate dry fecal matter production and apparent digestibility coefficients, is therefore recommended. The use of LIPE®, fibers in indigestible acid detergent and indigestible dry matter as indicators, both latter incubated for 288 hours, result in accurate estimates of dry fecal matter production in confined buffaloes, fed on a forage based diet.

  13. Standard operating procedures for collection of soil and sediment samples for the Sediment-bound Contaminant Resiliency and Response (SCoRR) strategy pilot study

    Science.gov (United States)

    Fisher, Shawn C.; Reilly, Timothy J.; Jones, Daniel K.; Benzel, William M.; Griffin, Dale W.; Loftin, Keith A.; Iwanowicz, Luke R.; Cohl, Jonathan A.

    2015-12-17

    An understanding of the effects on human and ecological health brought by major coastal storms or flooding events is typically limited because of a lack of regionally consistent baseline and trends data in locations proximal to potential contaminant sources and mitigation activities, sensitive ecosystems, and recreational facilities where exposures are probable. In an attempt to close this gap, the U.S. Geological Survey (USGS) has implemented the Sediment-bound Contaminant Resiliency and Response (SCoRR) strategy pilot study to collect regional sediment-quality data prior to and in response to future coastal storms. The standard operating procedure (SOP) detailed in this document serves as the sample-collection protocol for the SCoRR strategy by providing step-by-step instructions for site preparation, sample collection and processing, and shipping of soil and surficial sediment (for example, bed sediment, marsh sediment, or beach material). The objectives of the SCoRR strategy pilot study are (1) to create a baseline of soil-, sand-, marsh sediment-, and bed-sediment-quality data from sites located in the coastal counties from Maine to Virginia based on their potential risk of being contaminated in the event of a major coastal storm or flooding (defined as Resiliency mode); and (2) respond to major coastal storms and flooding by reoccupying select baseline sites and sampling within days of the event (defined as Response mode). For both modes, samples are collected in a consistent manner to minimize bias and maximize quality control by ensuring that all sampling personnel across the region collect, document, and process soil and sediment samples following the procedures outlined in this SOP. Samples are analyzed using four USGS-developed screening methods—inorganic geochemistry, organic geochemistry, pathogens, and biological assays—which are also outlined in this SOP. Because the SCoRR strategy employs a multi-metric approach for sample analyses, this

  14. Phase identification of quasi-periodic flow measured by particle image velocimetry with a low sampling rate

    International Nuclear Information System (INIS)

    Pan, Chong; Wang, Hongping; Wang, Jinjun

    2013-01-01

    This work mainly deals with the proper orthogonal decomposition (POD) time coefficient method used for extracting phase information from quasi-periodic flow. The mathematical equivalence between this method and the traditional cross-correlation method is firstly proved. A two-dimensional circular cylinder wake flow measured by time-resolved particle image velocimetry within a range of Reynolds numbers is then used to evaluate the reliability of this method. The effect of both the sampling rate and Reynolds number on the identification accuracy is finally discussed. It is found that the POD time coefficient method provides a convenient alternative for phase identification, whose feasibility in low-sampling-rate measurement has additional advantages for experimentalists. (paper)

  15. Changes According to Incubation Periods in Some Microbiological Characteristics at Soil Samples of Some Soil Series from the Gelemen Agricultural Administration

    OpenAIRE

    KARA, Emine Erman

    1998-01-01

    Changes according to incubation periods in some microbiological characteristics at soil samples of soil series from Gelemen Agricultural Administraction were investigated in this study. The results show that bacteria, actinomycet had values in the first periods of incubation (30ºC and field capacity) and in the following periods increased. However, fungus population changed depending upon series properties and reached maximum values 24th and 32th days after the beginning of incubation. During...

  16. Determination of different contaminants in selective drinking water samples collected from Peshawar valley area

    International Nuclear Information System (INIS)

    Ihsanullah; Khan, M.; Khattak, T.N.; Sattar, A.

    1999-01-01

    Among the pollutants carried through sewage, industrial effluents, fertilizers, pesticides; heavy metals and various pathogenic bacteria are directly related to human/animal diseases. Samples of drinking water were collected from different locations, in the Peshawar area. Cadmium, lead and copper levels in these samples were determined by potentiometric stripping analysis (PSA). The data indicated wide variation in the concentration of these heavy metals. Variation in results is discussed on the basis of some possible sources of contamination. The concentration of cadmium and lead in all the samples was higher compared to the values given in the guideline of World Health Organization (WHO) for drinking water. Copper was below the detection limit in majority of the samples. The values of Cd, Pb and Cu were in the range of 0.023-2.75, 0.025-1.88 and 0-0.67 mg/1 respectively. Various physical quality indices (ph, electrical conductivity and total solids) and pathogenic bacteria (E. coli and total coliforms) were also determined in water samples. Most of the drinking waters was found contaminated with higher levels of Cd and Pb and pathogenic bacteria and hence, considered unfit for drinking purposes. (author)

  17. Analysis Of Data Collected By Epidemio-Surveillance Network For ...

    African Journals Online (AJOL)

    Summary During the period 1996 - 2002, 82 suspected cases of pasteurellosis were recorded and 88 samples taken from suspected animals were collected and analysed by the national laboratory Laboratoire de Recherches Vétérinaires et Zootechniques de Farcha. Out of 82 suspected cases, only 7 % were confirmed by ...

  18. Evaluation of the collection of periodical publications pertaining to CIDN (Nuclear Information and Documentation Center): Part I

    International Nuclear Information System (INIS)

    Contreras, T.J.

    1994-01-01

    The main purpose of this paper is to identify the lacks of the collection of periodical publications pertaining to CIDN as a function of the information needs of the researching community, considering that the research roles are in changing process. The library services of alert, selective dissemination of information, and interlibrary loan are analyzed. The results attained in the first stage of this study will help to take decisions about the titles that is necessary to put into the discard. (Author)

  19. Field sampling, preparation procedure and plutonium analyses of large freshwater samples

    International Nuclear Information System (INIS)

    Straelberg, E.; Bjerk, T.O.; Oestmo, K.; Brittain, J.E.

    2002-01-01

    This work is part of an investigation of the mobility of plutonium in freshwater systems containing humic substances. A well-defined bog-stream system located in the catchment area of a subalpine lake, Oevre Heimdalsvatn, Norway, is being studied. During the summer of 1999, six water samples were collected from the tributary stream Lektorbekken and the lake itself. However, the analyses showed that the plutonium concentration was below the detection limit in all the samples. Therefore renewed sampling at the same sites was carried out in August 2000. The results so far are in agreement with previous analyses from the Heimdalen area. However, 100 times higher concentrations are found in the lowlands in the eastern part of Norway. The reason for this is not understood, but may be caused by differences in the concentrations of humic substances and/or the fact that the mountain areas are covered with snow for a longer period of time every year. (LN)

  20. Collection, pre-treatment and analyses of Cs-137 and Tc-99 in marine samples at the Institute of Marine Research (IMR), Norway

    International Nuclear Information System (INIS)

    Heldal, H.E.

    2010-01-01

    Full text: The Institute of Marine Research (IMR) is an important contributor to the Norwegian marine monitoring programme RAME (Radioactivity in the Marine Environment). RAME is funded by the Ministry of the Environment and coordinated by the Norwegian Radiation Protection Authority (NRPA). Sample collection is performed from IMRs research vessels in the open sea areas of the North-, Norwegian- and Barents Seas and in Norwegian fjords. The samples consist of biota (fish and other marine organisms), sediments and seawater. Biota samples are frozen onboard the ship and transported to IMR where the samples are subsequently ground up, freeze dried, homogenized and aliquoted into polyethylene counting boxes of appropriate size prior to analysis. Attempts are made to collect filets from 25 fish for each sample of large fish such as cod, haddock, saithe, red-fish and Greenland halibut. For smaller fish (e.g. blue whiting, polar cod, capelin and Atlantic herring) and other organisms such as amphipods, krill, and deep-sea shrimps, a sample of 2-3 kg of each species is taken. These samples are ground up whole. Sediment samples are collected using a Smoegen boxcorer, from where both surface samples and cores are taken. The samples are frozen onboard the ship. While half-frozen, the cores are cut into slices of 1 or 2 cm thickness on board the ship, then frozen again and transported to IMR where they are treated as described above for the biota samples. Large volumes (typically 50-200 L) of seawater are needed in order to get enough material for analysis. Pre-treatment of the samples in the field is therefore an advantage. Surface samples (5 m) of seawater are collected from a shipboard pump, while a CTD-rosette multi-bottle sampler with 12 10 L samplers is used to collect seawater from depths below 5 meters. For the analysis of Cs-137, Cu 2 [Fe(CN) 6 ]-impregnated cotton filters are used for the pre-concentration. One pre-filter without impregnation, two Cu 2 [Fe(CN) 6

  1. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF URINE SAMPLES FOR METAL, PESTICIDE, AND CREATININE ANALYSIS (F10)

    Science.gov (United States)

    The purpose of this SOP is to describe the procedures for collection, storage, and shipment of urine samples for metal, pesticides, and creatinine analysis. Samples were collected on Days 2 and 8 of each Cycle. The Day 2 sample was analyzed for metals and creatinine. The Day 8...

  2. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE AND SHIPMENT OF URINE SAMPLES FOR SELECTED METALS AND PESTICIDES (UA-F-20.1)

    Science.gov (United States)

    The purpose of this SOP is to guide the collection, storage, and shipment of urine samples collected for the NHEXAS Arizona project. This SOP provides a brief description of sample, collection, preservation, storage, shipping, and custody procedures. This procedure was followed ...

  3. Characterization Data Package for Containerized Sludge Samples Collected from Engineered Container SCS-CON-210

    Energy Technology Data Exchange (ETDEWEB)

    Fountain, Matthew S.; Fiskum, Sandra K.; Baldwin, David L.; Daniel, Richard C.; Bos, Stanley J.; Burns, Carolyn A.; Carlson, Clark D.; Coffey, Deborah S.; Delegard, Calvin H.; Edwards, Matthew K.; Greenwood, Lawrence R.; Neiner, Doinita; Oliver, Brian M.; Pool, Karl N.; Schmidt, Andrew J.; Shimskey, Rick W.; Sinkov, Sergey I.; Snow, Lanee A.; Soderquist, Chuck Z.; Thompson, Christopher J.; Trang-Le, Truc LT; Urie, Michael W.

    2013-09-10

    This data package contains the K Basin sludge characterization results obtained by Pacific Northwest National Laboratory during processing and analysis of four sludge core samples collected from Engineered Container SCS-CON-210 in 2010 as requested by CH2M Hill Plateau Remediation Company. Sample processing requirements, analytes of interest, detection limits, and quality control sample requirements are defined in the KBC-33786, Rev. 2. The core processing scope included reconstitution of a sludge core sample distributed among four to six 4-L polypropylene bottles into a single container. The reconstituted core sample was then mixed and subsampled to support a variety of characterization activities. Additional core sludge subsamples were combined to prepare a container composite. The container composite was fractionated by wet sieving through a 2,000 micron mesh and a 500-micron mesh sieve. Each sieve fraction was sampled to support a suite of analyses. The core composite analysis scope included density determination, radioisotope analysis, and metals analysis, including the Waste Isolation Pilot Plant Hazardous Waste Facility Permit metals (with the exception of mercury). The container composite analysis included most of the core composite analysis scope plus particle size distribution, particle density, rheology, and crystalline phase identification. A summary of the received samples, core sample reconstitution and subsampling activities, container composite preparation and subsampling activities, physical properties, and analytical results are presented. Supporting data and documentation are provided in the appendices. There were no cases of sample or data loss and all of the available samples and data are reported as required by the Quality Assurance Project Plan/Sampling and Analysis Plan.

  4. Comparison of overnight, morning and 24-hour urine collections in the assessment of diabetic microalbuminuria

    DEFF Research Database (Denmark)

    Eshøj, O; Feldt-Rasmussen, B; Larsen, M L

    1987-01-01

    With the aim of comparing different urine collection periods in the assessment of micro-albuminuria, urinary albumin excretion rates (AERs) were measured in samples from 24 h, overnight, and morning urine collections in 54 patients aged 17 to 62 years with insulin-dependent diabetes mellitus...... overnight and morning urine samples. These values were slightly improved by relating AER to the excretion of creatinine and it is concluded that overnight as well as morning urine collections can be used when diagnosing microalbuminuria in insulin-dependent diabetics. Furthermore the results show...

  5. Disposable Collection Kit for Rapid and Reliable Collection of Saliva

    OpenAIRE

    Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek

    2015-01-01

    Objectives To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. Methods The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 ?l) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method...

  6. Radioactivity measurements in moss (Hypnum cupressiforme) and lichen (Cladonia rangiformis) samples collected from Marmara region of Turkey

    Energy Technology Data Exchange (ETDEWEB)

    Belivermis, Murat, E-mail: belmurat@istanbul.edu.t [Istanbul University, Faculty of Science, Department of Biology, 34134 Vezneciler, Istanbul (Turkey); Cotuk, Yavuz, E-mail: cotukyav@istanbul.edu.t [Istanbul University, Faculty of Science, Department of Biology, 34134 Vezneciler, Istanbul (Turkey)

    2010-11-15

    The present study was conducted to compare the {sup 137}Cs, {sup 40}K, {sup 232}Th, and {sup 238}U activity concentrations in epigeic moss (Hypnum cupressiforme) and lichen (Cladonia rangiformis). The activity levels in 37 moss and 38 lichen samples collected from the Marmara region of Turkey were measured using a gamma spectrometer equipped with a high purity germanium (HPGe) detector. The activity concentrations of {sup 137}Cs, {sup 40}K, {sup 232}Th, and {sup 238}U in the moss samples were found to be in the range of 0.36-8.13, 17.1-181.1, 1.51-6.17, and 0.87-6.70 Bq kg{sup -1} respectively, while these values were below detection limit (BDL)-4.32, 16.6-240.0, 1.32-6.47, and BDL-3.57 Bq kg{sup -1} respectively in lichen. The average moss/lichen activity ratios of {sup 137}Cs, {sup 40}K, {sup 232}Th, and {sup 238}U were found to be 1.32 {+-} 0.57, 2.79 {+-} 1.67, 2.11 {+-} 0.82, and 2.19 {+-} 1.02, respectively. Very low {sup 137}Cs concentrations were observed in moss and lichen samples compared to soil samples collected from the same locations in a previous study. Seasonal variations of the measured radionuclide activities were also examined in the three sampling stations.

  7. Bovine milk sampling efficiency for pregnancy-associated glycoproteins (PAG) detection test

    Energy Technology Data Exchange (ETDEWEB)

    Silva, H. K. da; Cassoli, L.D.; Pantoja, J.F.C.; Cerqueira, P.H.R.; Coitinho, T.B.; Machado, P.F.

    2016-07-01

    Two experiments were conducted to verify whether the time of day at which a milk sample is collected and the possible carryover in the milking system may affect pregnancy-associated glycoproteins (PAG) levels and, consequently, the pregnancy test results in dairy cows. In experiment one, we evaluated the effect of time of day at which the milk sample is collected from 51 cows. In experiment two, which evaluated the possible occurrence of carryover in the milk meter milking system, milk samples from 94 cows belonging to two different farms were used. The samples were subjected to pregnancy test using ELISA methodology to measure PAG concentrations and to classify the samples as positive (pregnant), negative (nonpregnant), or suspicious (recheck). We found that the time of milking did not affect the PAG levels. As to the occurrence of carryover in the milk meter, the PAG levels of the samples collected from Farm-2 were heavily influenced by a carryover effect compared with the samples from Farm-1. Thus, milk samples submitted to a pregnancy test can be collected during the morning or the evening milking. When the sample is collected from the milk meters, periodic equipment maintenance should be noted, including whether the milk meter is totally drained between different animals’ milking and equipment cleaning between milking is performed correctly to minimize the occurrence of carryover, thereby avoiding the effect on PAG levels and, consequently, the pregnancy test results. Therefore, a single milk sample can be used for both milk quality tests and pregnancy test.

  8. Bovine milk sampling efficiency for pregnancy-associated glycoproteins (PAG) detection test

    International Nuclear Information System (INIS)

    Silva, H. K. da; Cassoli, L.D.; Pantoja, J.F.C.; Cerqueira, P.H.R.; Coitinho, T.B.; Machado, P.F.

    2016-01-01

    Two experiments were conducted to verify whether the time of day at which a milk sample is collected and the possible carryover in the milking system may affect pregnancy-associated glycoproteins (PAG) levels and, consequently, the pregnancy test results in dairy cows. In experiment one, we evaluated the effect of time of day at which the milk sample is collected from 51 cows. In experiment two, which evaluated the possible occurrence of carryover in the milk meter milking system, milk samples from 94 cows belonging to two different farms were used. The samples were subjected to pregnancy test using ELISA methodology to measure PAG concentrations and to classify the samples as positive (pregnant), negative (nonpregnant), or suspicious (recheck). We found that the time of milking did not affect the PAG levels. As to the occurrence of carryover in the milk meter, the PAG levels of the samples collected from Farm-2 were heavily influenced by a carryover effect compared with the samples from Farm-1. Thus, milk samples submitted to a pregnancy test can be collected during the morning or the evening milking. When the sample is collected from the milk meters, periodic equipment maintenance should be noted, including whether the milk meter is totally drained between different animals’ milking and equipment cleaning between milking is performed correctly to minimize the occurrence of carryover, thereby avoiding the effect on PAG levels and, consequently, the pregnancy test results. Therefore, a single milk sample can be used for both milk quality tests and pregnancy test.

  9. Analytical results for 544 water samples collected in the Attean Quartz Monzonite in the vicinity of Jackman, Maine

    Science.gov (United States)

    Ficklin, W.H.; Nowlan, G.A.; Preston, D.J.

    1983-01-01

    Water samples were collected in the vicinity of Jackman, Maine as a part of the study of the relationship of dissolved constituents in water to the sediments subjacent to the water. Each sample was analyzed for specific conductance, alkalinity, acidity, pH, fluoride, chloride, sulfate, phosphate, nitrate, sodium, potassium, calcium, magnesium, and silica. Trace elements determined were copper, zinc, molybdenum, lead, iron, manganese, arsenic, cobalt, nickel, and strontium. The longitude and latitude of each sample location and a sample site map are included in the report as well as a table of the analytical results.

  10. Photolysis of Periodate and Periodic Acid in Aqueous Solution

    DEFF Research Database (Denmark)

    Sehested, Knud; Kläning, U. K.

    1978-01-01

    The photochemistry of periodate and periodic acid in aqueous solution was studied (i) by quantum yield measurements at low light intensity (ii) by flash photolysis, and (iii) by photolysis of glassy samples at 77 K. The photochemical studies were supplemented with pulse radiolysis studies...... of aqueous periodate solutions and with kinetic studies using stopped-flow technique. In strongly alkaline solution the photodecomposition of periodate proceeds via formation of O– and IVI. At pH solution O3 P is formed in a small...

  11. 77 FR 36544 - Agency Information Collection Activities; Proposed Collection; Comment Request; Survey on the...

    Science.gov (United States)

    2012-06-19

    ... 2013 with the initial data collection for select restaurant facility types, followed by the initial... (baseline collection period data collection survey measurement) period Restaurants Full Service 2013 2016 2019 Restaurants Fast Food Restaurants. Institutional Foodservice........ Hospitals 2014 2017 2020...

  12. Identification of Colored Dyes that are Resistant to Fading on Exposure to Ethylene Oxide; Use with Indicating FTA™ Sample Collection Cards

    Directory of Open Access Journals (Sweden)

    Nina Moran

    2016-01-01

    Full Text Available Regulatory Standards and Forensic Communities are expressing an expectation for HID products to be certified as “DNA-free.” Recently, “DNA-free” status was described for HID-related products using ethylene oxide (EtO; this gas reduces the presence of amplifiable DNA and causes minimal interference to downstream HID-analytical methods. During sample collection, indicating cards, for example, Indicating FTA™ (GE Healthcare Life Sciences, UK, are used to collect and store buccal cell DNA. These cards contain a dye which changes color on application of a colorless sample. Generating “DNA-free” indicating cards using EtO should not impact the dyes' ability to indicate sample location or the efficacy of the card in downstream HID-analytical methods. This study was initiated to identify alternative dyes to those currently used with sample indicating collection cards. The most promising, dyes when applied to cellulose papers exhibited a uniform color distribution and excellent sample indicating properties even when mixed with chemicals associated with FTA™. When dyed cellulose papers were exposed to EtO, ultraviolet radiation, elevated temperature, and humidity, negligible fading or discoloration was observed. The presence of these dyes on cellulose papers did not interfere with direct short tandem repeat (STR profiling. Allelic concordance, first pass success rate, and mean peak heights were comparable to samples applied to Indicating FTA. Biological samples applied to EtO-treated dyed cellulose papers and stored >1 month produced full STR profiles of sufficient quality to allow submission to DNA databases, confirming negligible interference from EtO treatment. These alternative sample indicating dyes resist EtO-mediated fading while fulfilling the Forensic Community's expectation for “DNA-free” with negligible impact on collection card performance.

  13. Measurement of radon exhalation rates in some soil samples collected near the international monument Taj Mahal, Agra

    International Nuclear Information System (INIS)

    Sharma, Jyoti; Kumar, Rupesh; Indolia, R.S.; Swarup, R.; Mahur, A.K.; Singh, Hargyan; Sonkawade, R.G.

    2011-01-01

    Human beings are exposed to ionizing radiation from natural sources due to the occurrence of natural radioactive elements in solids, rocks, sand, soil etc. used as building construction materials and to the internal exposure from radioactive elements through good, water and air. Radon exhalation rate is of prime importance for the estimation of radiation risk from various materials. In the present study soil samples collected near the Tajmahal Agra. Sealed Can Technique was adopted for radon exhalation measurements. All the soil samples collected were grinded, dried and sieved through a 100 mesh sieve. Equal amount of each sieved (100μm grain size) sample (100 gm) was placed at the base of the Cans of 7.5 cm height and 7.0 cm diameter similar to those used in the calibration experiment (Singh et al., 1997). LR-115 type II plastic track detector (2 cm x 2 cm) was fixed on the top inside of the cylindrical Can. Radon exhalation rate varies from 529 mBqm -2 h -1 to 1254 mBqm -2 h -1 . The results will be presented. (author)

  14. A Prototype Ice-Melting Probe for Collecting Biological Samples from Cryogenic Ice at Low Pressure

    Science.gov (United States)

    Davis, Ashley

    2017-08-01

    In the Solar System, the surface of an icy moon is composed of irregular ice formations at cryogenic temperatures (pumps. The device contains a heated conical probe with a central orifice, which is forced into surface ice and directs the meltwater upward into a reservoir. The force on the probe is proportional to the height of meltwater (pressure) obtained in the system and allows regulation of the melt rate and temperature of the sample. The device can collect 5-50 mL of meltwater from the surface of an ice block at 233-208 K with an environmental pressure of less than 10-2 atm while maintaining a sample temperature between 273 and 293 K. These conditions maintain most biological samples in a pristine state and maintain the integrity of most organisms' structure and function.

  15. Headspace vapor characterization of Hanford Waste Tank 241-T-110: Results from samples collected on August 31, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    McVeety, B.D.; Thomas, B.L.; Evans, J.C.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-T-110 (Tank T-110) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5056. Samples were collected by WHC on August 31, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  16. Headspace vapor characterization of Hanford Waste Tank 241-TX-111: Results from samples collected on October 12, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    Pool, K.H.; Clauss, T.W.; Evans, J.C.

    1996-06-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-TX-111 (Tank TX-111) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5069. Samples were collected by WHC on October 12, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  17. Headspace vapor characterization of Hanford Waste Tank 241-SX-109: Results from samples collected on August 1, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    Pool, K.H.; Clauss, T.W.; Evans, J.C.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-SX-109 (Tank SX-109) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5048. Samples were collected by WHC on August 1, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  18. Headspace vapor characterization of Hanford Waste Tank 241-SX-104: Results from samples collected on July 25, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    Thomas, B.L.; Clauss, T.W.; Evans, J.C.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-SX-104 (Tank SX-104) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5049. Samples were collected by WHC on July 25, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  19. Headspace vapor characterization of Hanford Waste Tank 241-S-112: Results from samples collected on July 11, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    Clauss, T.W.; Pool, K.H.; Evans, J.C.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage Tank 241-S-112 (Tank S-112) at the Hanford. Pacific Northwest National Laboratory (PNNL) is contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5044. Samples were collected by WHC on July 11, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  20. Headspace vapor characterization of Hanford Waste Tank 241-SX-105: Results from samples collected on July 26, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    Pool, K.H.; Clauss, T.W.; Evans, J.C.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-SX-105 (Tank SX-105) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5047. Samples were collected by WHC on July 26, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  1. The international Genome sample resource (IGSR): A worldwide collection of genome variation incorporating the 1000 Genomes Project data.

    Science.gov (United States)

    Clarke, Laura; Fairley, Susan; Zheng-Bradley, Xiangqun; Streeter, Ian; Perry, Emily; Lowy, Ernesto; Tassé, Anne-Marie; Flicek, Paul

    2017-01-04

    The International Genome Sample Resource (IGSR; http://www.internationalgenome.org) expands in data type and population diversity the resources from the 1000 Genomes Project. IGSR represents the largest open collection of human variation data and provides easy access to these resources. IGSR was established in 2015 to maintain and extend the 1000 Genomes Project data, which has been widely used as a reference set of human variation and by researchers developing analysis methods. IGSR has mapped all of the 1000 Genomes sequence to the newest human reference (GRCh38), and will release updated variant calls to ensure maximal usefulness of the existing data. IGSR is collecting new structural variation data on the 1000 Genomes samples from long read sequencing and other technologies, and will collect relevant functional data into a single comprehensive resource. IGSR is extending coverage with new populations sequenced by collaborating groups. Here, we present the new data and analysis that IGSR has made available. We have also introduced a new data portal that increases discoverability of our data-previously only browseable through our FTP site-by focusing on particular samples, populations or data sets of interest. © The Author(s) 2016. Published by Oxford University Press on behalf of Nucleic Acids Research.

  2. Cortisol and prolactin concentrations during repeated blood sample collection from freely moving, mouse-sized mammals (Phodopus spp.).

    Science.gov (United States)

    Reburn, C J; Wynne-Edwards, K E

    2000-04-01

    Validation of a method for obtaining blood samples that does not change cortisol or prolactin concentrations yet allows serial blood samples to be collected from animals under anesthesia, without prior handling, from freely interacting social groups of small mammals. Results from five experiments are reported. Male dwarf hamsters (Phodopus spp.) were housed in modified home cages under continuous flow of compressed air that could be switched to isoflurane in O2 vehicle without approaching the cages. Dwarf hamsters respond to manual restraint with behavioral distress and increase in the concentration of the dominant glucocorticoid, cortisol, and decrease in prolactin concentration. Both effects are evident within one minute. In contrast, when this new method was used, neither cortisol nor prolactin changed in response to repeated sample collection (up to 8 successive samples at 2 hour intervals), prolonged isoflurane exposure, or substantial blood volume reduction (30%). Prolactin concentration was suppressed and cortisol concentration was increased in response to stimuli from other hamsters tested without anesthesia. Suppression of prolactin concentration was graded in response to the degree of stress and equaled the pharmacologic reduction caused by bromocryptine mesylate (50 microg of CB154 x 3 days). The technique is superior to alternatives for studies of behavioral endocrinology of freely interacting small mammals.

  3. Feasibility of automated speech sample collection with stuttering children using interactive voice response (IVR) technology.

    Science.gov (United States)

    Vogel, Adam P; Block, Susan; Kefalianos, Elaina; Onslow, Mark; Eadie, Patricia; Barth, Ben; Conway, Laura; Mundt, James C; Reilly, Sheena

    2015-04-01

    To investigate the feasibility of adopting automated interactive voice response (IVR) technology for remotely capturing standardized speech samples from stuttering children. Participants were 10 6-year-old stuttering children. Their parents called a toll-free number from their homes and were prompted to elicit speech from their children using a standard protocol involving conversation, picture description and games. The automated IVR system was implemented using an off-the-shelf telephony software program and delivered by a standard desktop computer. The software infrastructure utilizes voice over internet protocol. Speech samples were automatically recorded during the calls. Video recordings were simultaneously acquired in the home at the time of the call to evaluate the fidelity of the telephone collected samples. Key outcome measures included syllables spoken, percentage of syllables stuttered and an overall rating of stuttering severity using a 10-point scale. Data revealed a high level of relative reliability in terms of intra-class correlation between the video and telephone acquired samples on all outcome measures during the conversation task. Findings were less consistent for speech samples during picture description and games. Results suggest that IVR technology can be used successfully to automate remote capture of child speech samples.

  4. Elemental analysis of air particulate samples in Jakarta area by x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Yumiarti; Yusuf, M.; Mellawati, June; Menry, Yulizon; Surtipanti S

    1998-01-01

    Determination of elements in air particulate samples collected from Jakarta, especially from industrial area Pulo Gadung, also from residence, office, and recreation sites had been carried out. The samples collected periodically from August through December 1996. The elements were analyzed by X-ray fluorescence spectrometry method. Quantitative and qualitative analyses were done using QXAS AXIL (Quantitative X-ray Analysis System of x-ray Spectra by Iterative Least squares fitting) and QAES (Quantitative Analyses of Environmental Samples) package program. Results of the analyses showed that the content of heavy metal elements in air particulate samples from all areas studied were still below the maximum permissible concentration. (authors)

  5. Chemical and biological evaluation of essential oil from Saussurea costus (Falc.) Lipsch. from Garhwal Himalaya collected at different harvesting periods.

    Science.gov (United States)

    Benedetto, Cristina; D'Auria, Maurizio; Mecca, Marisabel; Prasad, Pratti; Singh, Pramod; Singh, Sandeep; Sinisgalli, Chiara; Milella, Luigi

    2018-02-19

    The purpose of this study is the determination of chemical composition and antioxidant activity of essential oils (EOs) from Saussurea costus (Falc.) Lipsch. Roots have been collected on December of the first plant year (IY) and in April, August and December of the third plant year (I, 6B, D7). A GC analysis was carried out for achieving this purpose. Subsequently, total polyphenol content (TPC) and antioxidant activity measured by DPPH, FRAP and BCB assays were evaluated. Three different statistical methods: Relative Antioxidant Capacity Index (RACI), Pearson's correlation coefficient (r) and PCA, were used to compare results obtained and underline EO relationships. From the results obtained, it was possible to observe how the collection period of the EO, in particular both the month and the year of collection, influences the metabolite profile.

  6. Designing an enhanced groundwater sample collection system

    International Nuclear Information System (INIS)

    Schalla, R.

    1994-10-01

    As part of an ongoing technical support mission to achieve excellence and efficiency in environmental restoration activities at the Laboratory for Energy and Health-Related Research (LEHR), Pacific Northwest Laboratory (PNL) provided guidance on the design and construction of monitoring wells and identified the most suitable type of groundwater sampling pump and accessories for monitoring wells. The goal was to utilize a monitoring well design that would allow for hydrologic testing and reduce turbidity to minimize the impact of sampling. The sampling results of the newly designed monitoring wells were clearly superior to those of the previously installed monitoring wells. The new wells exhibited reduced turbidity, in addition to improved access for instrumentation and hydrologic testing. The variable frequency submersible pump was selected as the best choice for obtaining groundwater samples. The literature references are listed at the end of this report. Despite some initial difficulties, the actual performance of the variable frequency, submersible pump and its accessories was effective in reducing sampling time and labor costs, and its ease of use was preferred over the previously used bladder pumps. The surface seals system, called the Dedicator, proved to be useful accessory to prevent surface contamination while providing easy access for water-level measurements and for connecting the pump. Cost savings resulted from the use of the pre-production pumps (beta units) donated by the manufacturer for the demonstration. However, larger savings resulted from shortened field time due to the ease in using the submersible pumps and the surface seal access system. Proper deployment of the monitoring wells also resulted in cost savings and ensured representative samples

  7. Isolation of endothelial colony-forming cells from blood samples collected from the jugular and cephalic veins of healthy adult horses.

    Science.gov (United States)

    Sharpe, Ashley N; Seeto, Wen J; Winter, Randolph L; Zhong, Qiao; Lipke, Elizabeth A; Wooldridge, Anne A

    2016-10-01

    OBJECTIVE To evaluate optimal isolation of endothelial colony-forming cells (ECFCs) from peripheral blood of horses. SAMPLE Jugular and cephalic venous blood samples from 17 adult horses. PROCEDURES Each blood sample was divided; isolation was performed with whole blood adherence (WBA) and density gradient centrifugation (DGC). Isolated cells were characterized by uptake of 1,1'-dioctadecyl-3,3,3',3'-tetramethylindocarbocyanine perchlorate-labeled acetylated low-density lipoprotein (DiI-Ac-LDL), vascular tubule formation, and expression of endothelial (CD34, CD105, vascular endothelial growth factor receptor-2, and von Willebrand factor) and hematopoietic (CD14) cell markers by use of indirect immunofluorescence assay (IFA) and flow cytometry. RESULTS Colonies with cobblestone morphology were isolated from 15 of 17 horses. Blood collected from the cephalic vein yielded colonies significantly more often (14/17 horses) than did blood collected from the jugular vein (8/17 horses). Of 14 cephalic blood samples with colonies, 13 were obtained with DGC and 8 with WBA. Of 8 jugular blood samples with colonies, 8 were obtained with DGC and 4 with WBA. Colony frequency (colonies per milliliter of blood) was significantly higher for cephalic blood samples and samples isolated with DGC. Cells formed vascular tubules, had uptake of DiI-Ac-LDL, and expressed endothelial markers by use of IFA and flow cytometry, which confirmed their identity as ECFCs. CONCLUSIONS AND CLINICAL RELEVANCE Maximum yield of ECFCs was obtained for blood samples collected from both the jugular and cephalic veins and use of DGC to isolate cells. Consistent yield of ECFCs from peripheral blood of horses will enable studies to evaluate diagnostic and therapeutic uses.

  8. Evaluation of human papillomavirus detection by Abbott m2000 system on samples collected by FTA Elute™ Card in a Chinese HIV-1 positive population.

    Science.gov (United States)

    Qin, Yu; Zhang, Hongyun; Marlowe, Natalia; Fei, Mandong; Yu, Judy; Lei, Xiaoqin; Yu, Lulu; Zhang, Jia; Cao, Di; Ma, Li; Chen, Wen

    2016-12-01

    HIV+/AIDS women have an increased risk of developing into CIN and cervical cancer compared to the general population. Limited medical resource and the lack of AIDS relevant knowledge impair the coverage and efficiency of cervical cancer screening. To compare the clinical performance of self-collected dry storage medium (FTA Elute card) and physician-collected PreservCyt medium in detection of high risk human papillomavirus (HR HPV) among HIV-1 positive population. Three hundred HIV-1 positive women (aged 25-65) were recruited from Yunnan infectious hospital. Two cervicovaginal samples were collected from each participant: one was collected by the women themselves and applied on a FTA Elute card; the other one was collected by a physician and stored in PreservCyt solution. All the samples were tested for 14 HR HPV using Abbott RealTime High Risk HPV assay. Biopsies were taken for histological diagnosis if any abnormal impression was noticed under colposcopy. 291 (97.0%) of participants were eligible for this study. 101 (34.70%) participants were found HR HPV positive in both FTA card and PreservCyt samples, and 19 (6.53%) women were diagnosed as CIN2+. The HR HPV positive rate on samples collected by FTA Elute card and PreservCyt solution was 42.61% and 39.86%, respectively. The overall agreement was 87% (kappa=0.731) between FTA card and PreservCyt. The clinical sensitivity and specificity of FTA card and PreservCyt were 100%, 61.39% and 100%, 64.33%, respectively. In this study, FTA Elute card demonstrated a good performance on self-collected sample for HR HPV detection in HIV-1 positive population. For the women from low-resource area with HIV-1 infection, FTA Elute card could be an attractive sample collection method for cervical cancer screening. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Handbook: Collecting Groundwater Samples from Monitoring Wells in Frenchman Flat, CAU 98

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, Jenny [Desert Research Inst. (DRI), Reno, NV (United States); Lyles, Brad [Desert Research Inst. (DRI), Reno, NV (United States); Cooper, Clay [Desert Research Inst. (DRI), Reno, NV (United States); Hershey, Ron [Desert Research Inst. (DRI), Reno, NV (United States); Healey, John [Desert Research Inst. (DRI), Reno, NV (United States)

    2015-06-01

    Frenchman Flat basin on the Nevada National Security Site (NNSS) contains Corrective Action Unit (CAU) 98, which is comprised of ten underground nuclear test locations. Environmental management of these test locations is part of the Underground Test Area (UGTA) Activity conducted by the U.S. Department of Energy (DOE) under the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended) with the U.S. Department of Defense (DOD) and the State of Nevada. A Corrective Action Decision Document (CADD)/Corrective Action Plan (CAP) has been approved for CAU 98 (DOE, 2011). The CADD/CAP reports on the Corrective Action Investigation that was conducted for the CAU, which included characterization and modeling. It also presents the recommended corrective actions to address the objective of protecting human health and the environment. The recommended corrective action alternative is “Closure in Place with Modeling, Monitoring, and Institutional Controls.” The role of monitoring is to verify that Contaminants of Concern (COCs) have not exceeded the Safe Drinking Water Act (SDWA) limits (Code of Federal Regulations, 2014) at the regulatory boundary, to ensure that institutional controls are adequate, and to monitor for changed conditions that could affect the closure conditions. The long-term closure monitoring program will be planned and implemented as part of the Closure Report stage after activities specified in the CADD/CAP are complete. Groundwater at the NNSS has been monitored for decades through a variety of programs. Current activities were recently consolidated in an NNSS Integrated Sampling Plan (DOE, 2014). Although monitoring directed by the plan is not intended to meet the FFACO long-term monitoring requirements for a CAU (which will be defined in the Closure Report), the objective to ensure public health protection is similar. It is expected that data collected in accordance with the plan will support the transition to long-term monitoring at each

  10. Peripheral blood collection

    DEFF Research Database (Denmark)

    Franken, Carmen; Remy, Sylvie; Lambrechts, Nathalie

    2016-01-01

    A crucial challenge for gene expression analysis in human biomonitoring studies on whole blood samples is rapid sample handling and mRNA stabilization. This study was designed to evaluate the impact of short bench times (less than 30 min) on yield, quality and gene expression of mRNA in the prese......A crucial challenge for gene expression analysis in human biomonitoring studies on whole blood samples is rapid sample handling and mRNA stabilization. This study was designed to evaluate the impact of short bench times (less than 30 min) on yield, quality and gene expression of m......RNA in the presence of different stabilization buffers (TempusTM Blood RNA tube and RNAlater® Stabilization Reagent). Microarray analyzes showed significant changes over short periods of time in expression of a considerate part of the transcriptome (2356 genes) with a prominent role for NFкB-, cancer......- and glucocorticoid-mediated networks, and specifically interleukin-8 (IL-8). These findings suggest that even short bench times affect gene expression, requiring to carry out blood collection in a strictly standardized way. © 2016 Informa UK Limited, trading as Taylor & Francis Group....

  11. Sampling and examination methods used for TMI-2 samples

    International Nuclear Information System (INIS)

    Marley, A.W.; Akers, D.W.; McIsaac, C.V.

    1988-01-01

    The purpose of this paper is to summarize the sampling and examination techniques that were used in the collection and analysis of TMI-2 samples. Samples ranging from auxiliary building air to core debris were collected and analyzed. Handling of the larger samples and many of the smaller samples had to be done remotely and many standard laboratory analytical techniques were modified to accommodate the extremely high radiation fields associated with these samples. The TMI-2 samples presented unique problems with sampling and the laboratory analysis of prior molten fuel debris. 14 refs., 8 figs

  12. Periodicity in Age-Resolved Populations

    Science.gov (United States)

    Esipov, Sergei

    We discuss the interplay between the non-linear diffusion and age-resolved population dynamics. Depending on the age properties of collective migration the system may exhibit continuous joint expansion of all ages or continuous expansion with age segregation. Between these two obvious limiting regimes there is an interesting window of periodic expansion, which has been previously used by us in modeling bacterial colonies of Proteus mirabilis. In order to test whether the age-dependent collective migration leads to periodicity in other systems we performed a Fourier analysis of historical data on ethnic expansions and found multiple co-existing periods of activity.

  13. Monitoring PCDD/Fs in soil and herbage samples collected in the neighborhood of a hazardous waste incinerator after five years of operation

    Energy Technology Data Exchange (ETDEWEB)

    Nadal, M.; Bocio, A.; Schuhmacher, M.; Liobet, J.M.; Domingo, J.L. [Rovira i Virgili Univ., Reus (Spain); Diaz-Ferrero, J. [Inst. Quimic de Sarria, Barcelona (Spain)

    2004-09-15

    Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) are among the most dangerous environmental pollutants, usually generated during combustion processes. Until recently, waste incineration was widely referenced as one of the most important sources of PCDD/F release to the atmosphere. In 1999, the only hazardous waste incinerator (HWI) in Spain began regular operations. This facility is placed in Tarragona, Catalonia. The presence of this HWI, as well as that of a municipal solid waste incinerator (MSWI) at a few kilometers, increased the concern of the public opinion in relation to the potential toxic emissions, especially those of metals and PCDD/Fs, which could affect the health of the population living in the area. Previously to regular operations (1996) the baseline levels of PCDD/Fs in soil and vegetation samples collected near the HWI were determined. A second survey was carried out two years later (1998) in order to establish the temporal variation in PCDD/F concentrations in soil and vegetation samples taken at the same sampling points. Vegetation is considered an adequate short-term environmental monitor for PCDD/Fs. Therefore, in the surveillance program of the facility (1999-2003), herbage samples (40) were annually collected at the same sampling points in which baseline samples had been taken. Moreover, considering soil as a suitable long-term monitor for PCDD/Fs, 40 soil samples in this matrix were again collected in 2001 and 2003 to examine the temporal variations of PCDD/F levels in the area. In the present study, we present the concentrations of PCDD/Fs in soil and vegetation samples collected in the vicinity of the HWI after 5 years of regular operations.

  14. CHARACTERISTIC OF AIRBORNE PARTICULATE MATTER SAMPLES COLLECTED FROM TWO SEMI INDUSTRIAL SITES IN BANDUNG, INDONESIA

    Directory of Open Access Journals (Sweden)

    Diah Dwiana Lestiani

    2013-12-01

    Full Text Available Air particulate matter concentrations, black carbon as well as elemental concentrations in two semi industrial sites were investigated as a preliminary study for evaluation of air quality in these areas. Sampling of airborne particulate matter was conducted in July 2009 using a Gent stacked filter unit sampler and a total of 18 pairs of samples were collected. Black carbon was determined by reflectance measurement and elemental analysis was performed using particle induced X-ray emission (PIXE. Elements Na, Mg, Al, Si, P, S, Cl, K, Ca, Ti, Cr, Mn, Fe, Cu, Zn and As were detected. Twenty four hour PM2.5 concentration at semi industrial sites Kiaracondong and Holis ranged from 4.0 to 22.2 µg m-3, while the PM10 concentration ranged from 24.5 to 77.1 µg m-3. High concentration of crustal elements, sulphur and zinc were identified in fine and coarse fractions for both sites. The fine fraction data from both sites were analyzed using a multivariate principal component analysis and for Kiaracondong site, identified factors are attributed to sea-salt with soil dust, vehicular emissions and biomass burning, non ferrous smelter, and iron/steel work industry, while for Holis site identified factors are attributed to soil dust, industrial emissions, vehicular emissions with biomass burning, and sea-salt. Although particulate samples were collected from semi industrial sites, vehicular emissions constituted with S, Zn and BC were identified in both sites.

  15. 40 CFR 761.283 - Determination of the number of samples to collect and sample collection locations.

    Science.gov (United States)

    2010-07-01

    ...) MANUFACTURING, PROCESSING, DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS Sampling To Verify Completion of Self... cleanup verification conducted in accordance with § 761.61(a)(6), follow the procedures in paragraph (b... verification conducted in accordance with § 761.61(a)(6), follow the procedures in this section for locating...

  16. RECOMMENDED OPERATING PROCEDURE NO. 56: COLLECTION OF GASEOUS GRAB SAMPLES FROM COMBUSTION SOURCES FOR NITROUS OXIDE MEASUREMENT

    Science.gov (United States)

    The document is a recommended operating procedure, prepare or use in research activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). The procedure applies to the collection of gaseous grab samples from fossil fuel combustion sources for subsequent a...

  17. Guidelines for the processing and quality assurance of benthic invertebrate samples collected as part of the National Water-Quality Assessment Program

    Science.gov (United States)

    Cuffney, T.F.; Gurtz, M.E.; Meador, M.R.

    1993-01-01

    Benthic invertebrate samples are collected as part of the U.S. Geological Survey's National Water-Quality Assessment Program. This is a perennial, multidisciplinary program that integrates biological, physical, and chemical indicators of water quality to evaluate status and trends and to develop an understanding of the factors controlling observed water quality. The Program examines water quality in 60 study units (coupled ground- and surface-water systems) that encompass most of the conterminous United States and parts of Alaska and Hawaii. Study-unit teams collect and process qualitative and semi-quantitative invertebrate samples according to standardized procedures. These samples are processed (elutriated and subsampled) in the field to produce as many as four sample components: large-rare, main-body, elutriate, and split. Each sample component is preserved in 10-percent formalin, and two components, large-rare and main-body, are sent to contract laboratories for further processing. The large-rare component is composed of large invertebrates that are removed from the sample matrix during field processing and placed in one or more containers. The main-body sample component consists of the remaining sample materials (sediment, detritus, and invertebrates) and is subsampled in the field to achieve a volume of 750 milliliters or less. The remaining two sample components, elutriate and split, are used for quality-assurance and quality-control purposes. Contract laboratories are used to identify and quantify invertebrates from the large-rare and main-body sample components according to the procedures and guidelines specified within this document. These guidelines allow the use of subsampling techniques to reduce the volume of sample material processed and to facilitate identifications. These processing procedures and techniques may be modified if the modifications provide equal or greater levels of accuracy and precision. The intent of sample processing is to

  18. Performance of a New HPV Cervi-Collect Collection and Transportation Kit

    Directory of Open Access Journals (Sweden)

    M. Chernesky

    2012-01-01

    Full Text Available Background. Liquid-based Pap (L-Pap media are used for Pap and human papillomavirus (HPV testing. Objectives. To compare RealTime High Risk (HR HPV testing of a new collection kit (Cervi-Collect and PreservCyt L-Pap specimens. To determine ease of use and safety of Cervi-Collect. Methods. L-Pap samples (n=203 were tested with HC2 and RealTime HR HPV and Cervi-Collect with RealTime HR HPV. Discordant samples were genotyped. Results. L-Pap and Cervi-Collect specimens tested by RealTime HR HPV showed 93.1% agreement (Kappa 0.86. RealTime HR HPV and HC2 on L-Pap had 90.3% agreement (Kappa 0.80. RealTime HR HPV on Cervi-Collect and HC2 on L-Pap showed 88.2% agreement (Kappa 0.76. Sixteen of 21 samples which were HC2 negative and RealTime HR HPV positive on L-Pap or Cervi-Collect contained HR HPV genotypes. Eleven healthcare collectors were in strong agreement on a usability and safety questionnaire. Conclusion. Cervi-Collect samples were easy to collect and showed strong agreement with L-Pap samples tested with RealTime HR HPV or HC2.

  19. Comparison of noninvasive sample collection procedures for canine leishmaniasis diagnosis by PCR-hybridization

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Sidney de Almeida; Andrade, Antero Silva Ribeiro de [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)]. E-mail: vidasnino@yahoo.com.br; antero@cdtn.br; Ituassu, Leonardo Trindade; Melo, Maria Norma de [Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil)]. E-mail: melo@mono.icb.ufmg.br; ltituassu@yahoo.com.br

    2007-07-01

    The dogs are the main reservoir of the visceral leishmaniasis etiological agent Leishmania chagasi and these animals have to be systematically monitored. The aim of present work was to standardize a method for canine leishmaniasis diagnosis using DNA samples obtained by a noninvasive ways. Two kind of samples were compared: conjunctival swab and blood. The samples were analyzed by the Polymerase Chain Reaction (PCR) associated with the hybridization of {sup 32}P labeled DNA probes. An in vitro test was carried out using cotton swabs seeded with L. chagasi parasites at different cell numbers. After that, the PCR and hybridization sensitivity was evaluated in two groups of 23 seropositive dogs. Conjunctival swabs and 1,0 mL of blood were collected from each animal. 90 {mu}L of these blood were spotted onto filter paper and the remaining used to prepare the buffy coat. The DNA purification from cotton swabs was carried out through the phenol-chloroform (group 1) or boiling (group 2). The Wizard kit was used to DNA extraction from buffy coat. The filters were treated according to Dialab protocol. The analysis of the seeded samples showed that the PCR was able to identify until ten parasites while the following hybridization of the PCR products allows the detection of until one parasite. The PCR positivity for the conjunctival swabs were 73.9% and 52.2% respectively to the groups 1 and 2. For buffy coat the positivities were 43.5% and 56.5% respectively. The filters presented the lowest positivity. The hybridization step was not accomplished yet for these samples. (author)

  20. The Internet of Samples in the Earth Sciences (iSamples)

    Science.gov (United States)

    Carter, M. R.; Lehnert, K. A.

    2015-12-01

    Across most Earth Science disciplines, research depends on the availability of samples collected above, at, and beneath Earth's surface, on the moon and in space, or generated in experiments. Many domains in the Earth Sciences have recently expressed the need for better discovery, access, and sharing of scientific samples and collections (EarthCube End-User Domain workshops, 2012 and 2013, http://earthcube.org/info/about/end-user-workshops), as has the US government (OSTP Memo, March 2014). The Internet of Samples in the Earth Sciences (iSamples) is an initiative funded as a Research Coordination Network (RCN) within the EarthCube program to address this need. iSamples aims to advance the use of innovative cyberinfrastructure to connect physical samples and sample collections across the Earth Sciences with digital data infrastructures to revolutionize their utility for science. iSamples strives to build, grow, and foster a new community of practice, in which domain scientists, curators of sample repositories and collections, computer and information scientists, software developers and technology innovators engage in and collaborate on defining, articulating, and addressing the needs and challenges of physical samples as a critical component of digital data infrastructure. A primary goal of iSamples is to deliver a community-endorsed set of best practices and standards for the registration, description, identification, and citation of physical specimens and define an actionable plan for implementation. iSamples conducted a broad community survey about sample sharing and has created 5 different working groups to address the different challenges of developing the internet of samples - from metadata schemas and unique identifiers to an architecture of a shared cyberinfrastructure for collections, to digitization of existing collections, to education, and ultimately to establishing the physical infrastructure that will ensure preservation and access of the physical

  1. Diurnal patterns of salivary cortisol and DHEA using a novel collection device: electronic monitoring confirms accurate recording of collection time using this device.

    Science.gov (United States)

    Laudenslager, Mark L; Calderone, Jacqueline; Philips, Sam; Natvig, Crystal; Carlson, Nichole E

    2013-09-01

    The accurate indication of saliva collection time is important for defining the diurnal decline in salivary cortisol as well as characterizing the cortisol awakening response. We tested a convenient and novel collection device for collecting saliva on strips of filter paper in a specially constructed booklet for determination of both cortisol and DHEA. In the present study, 31 healthy adults (mean age 43.5 years) collected saliva samples four times a day on three consecutive days using filter paper collection devices (Saliva Procurement and Integrated Testing (SPIT) booklet) which were maintained during the collection period in a large plastic bottle with an electronic monitoring cap. Subjects were asked to collect saliva samples at awakening, 30 min after awakening, before lunch and 600 min after awakening. The time of awakening and the time of collection before lunch were allowed to vary by each subjects' schedule. A reliable relationship was observed between the time recorded by the subject directly on the booklet and the time recorded by electronic collection device (n=286 observations; r(2)=0.98). However, subjects did not consistently collect the saliva samples at the two specific times requested, 30 and 600 min after awakening. Both cortisol and DHEA revealed diurnal declines. In spite of variance in collection times at 30 min and 600 min after awakening, the slope of the diurnal decline in both salivary cortisol and DHEA was similar when we compared collection tolerances of ±7.5 and ±15 min for each steroid. These unique collection booklets proved to be a reliable method for recording collection times by subjects as well as for estimating diurnal salivary cortisol and DHEA patterns. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Tank vapor characterization project - Tank 241-U-112 headspace gas and vapor characterization: Results for homogeneity samples collected on December 6, 1996

    Energy Technology Data Exchange (ETDEWEB)

    Sklarew, D.S.; Pool, K.H.; Evans, J.C.; Hayes, J.C. [and others

    1997-09-01

    This report presents the results of analyses of samples taken from the headspace of waste storage tank 241-U-112 (Tank U-112) at the Hanford Site in Washington State. Samples were collected to determine the homogeneity of selected inorganic and organic headspace constitutents. Two risers (Riser 3 and Riser 6) were sampled at three different elevations (Bottom, Middle, and Top) within the tank. Tank headspace samples were collected by SGN Eurisys Service Corporation (SESC) and were analyzed by Pacific Northwest National Laboratory (PNNL) to determine headspace concentrations of selected non-radioactive analytes. Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Ammonia was determined to be above the immediate notification limit specified by the sampling and analysis plan.

  3. Collecting data from migrants in Ghana: Lessons learned using respondent-driven sampling

    Directory of Open Access Journals (Sweden)

    Samantha R. Lattof

    2018-03-01

    Full Text Available Background: Policymakers and program implementers require high-quality data on migrants and migration in low- and middle-income countries (LMIC; however, a shortage of high-quality data exists in these settings. Sampling migrant populations requires better techniques. Respondent-driven sampling (RDS may be one such solution. Objective: Using Ghana as a case study, the objectives of this paper are to: 1 assess RDS recruitment productivity, network size, and ties of internal migrants; 2 test for homophily; and 3 detail the successes of and challenges to implementing RDS in Ghana and how these lessons can be applied to migrant populations in other LMIC settings. Methods: This study used RDS to sample 625 rural-urban female migrants working as market porters (kayayei in Accra, Ghana. Results: This study generated the most comprehensive data set on kayayei to date. Network size increases as participants become more educated and migrate more often to Accra. Ethnic group membership is an important determinant of recruitment, with certain groups preferring to recruit from within. Employing members of the kayayei population to collect data built crucial trust. Conclusions: Whilst RDS is not a one-size-fits-all solution for sampling hard-to-reach migrants in LMIC, it can be a powerful tool to uncover and to recruit hard-to-reach migrant populations. In countries with multiple ethnolinguistic groups, recruiting a migrant population with greater ethnolinguistic overlap may facilitate quicker equilibrium. Contribution: This study expands the evidence base on use of RDS among migrant populations in LMIC and provides lessons learned to assist other researchers implementing RDS in LMIC settings.

  4. Daily self-sampling for high-risk human papillomavirus (HR-HPV) testing.

    Science.gov (United States)

    Sanner, Karin; Wikström, Ingrid; Gustavsson, Inger; Wilander, Erik; Lindberg, Julia Hedlund; Gyllensten, Ulf; Olovsson, Matts

    2015-12-01

    Self-sampling for HPV as part of primary screening is a well-tolerated method for women not attending organized Pap smear screening and could increase coverage of cervical cancer screening. To investigate if the prevalence of HR-HPV varies from day to day in infected women and if one single sample is reliable for detecting an ongoing infection. This is a prospective cohort study on 12 premenopausal and 13 postmenopausal women performing daily self-sampling for HR-HPV testing. They were all HR-HPV-positive 1-3 months ago. Postmenopausal women were sampled for 28 days and premenopausal women sampled during bleeding-free days in one menstrual cycle. A possible difference in viral load between the estrogen-dominated proliferative phase and the progesterone-dominated secretory phase was analyzed. Consistent results throughout the sampling period were observed for 19 women, with either a daily presence of HPV (14 women) or no HPV at all during the sampling period (5 women). Of 607 samples from 25 women, 596 were consistently positive or negative for HPV during the sampling period and 11 were inconsistent (2%). There was no difference in HPV copy number between the estrogen dominated proliferative or progesterone dominated secretory menstrual cycle phases. The major finding was a high degree of consistency concerning HR-HPV positivity and negativity of HR-HPV in vaginal fluid during a sustained period of daily self-sampling. It does not appear to matter whether the sample is collected in the proliferative or secretory phase. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Study on mixis potential of rotifer resting eggs ( Brachionus plicatilis) with different collection times and different preservation periods

    Science.gov (United States)

    Zhou, Li; Zheng, Yan; Xiang, Jian-Hai

    2001-09-01

    The present study investigated the possible changes in the mixis potential of rotifer resting eggs produced by a single stock of Brachionus plicatilis and collected and preserved annually from 1985 1998. Several clones derived from each batch of resting eggs were cultured under the same conditions for 21 days. The percentage of clones appearing resting eggs and the average yield of resting eggs produced from each clone were recorded and statistically analyzed to find the differences between the mixis potential of those resting egg batches. Results showed that different batches of resting eggs had different mictic levels among their descendent clones; but no regular relationship was found between the mixis potential of resting eggs and their collection times/preservation periods. Several internal and external factors that might affect the mixis potential of resting eggs were discussed.

  6. Fog-harvesting inspired by the Stenocara beetle—An analysis of drop collection and removal from biomimetic samples with wetting contrast

    Science.gov (United States)

    White, Beatrice; Sarkar, Anjishnu; Kietzig, Anne-Marie

    2013-11-01

    This work examines the fog-harvesting ability of patterned and non-patterned samples in spray chamber experiments. The samples were prepared from different materials and the patterns under investigation were channels, hydrophobic patches and hydrophilic patches of contrasting wettability to mimic and optimize the alleged natural fog-harvesting ability of the Stenocara beetle. Fog-harvesting results based on the amount of collected water showed no significant differences among all samples, as the influence of “wind” was found to be the more dominant factor compared to the samples’ wetting characteristics. Video analysis of the experiments, however, revealed differences in the water collection and water removal mechanisms and were concluded to be more helpful than water collection results in the assessment of the various competing mechanisms in fog-harvesting experiments. The analysis with regard to surface wettability is based on drop rolling on the surface and roll-off into air, respectively. All patterned and most non-patterned samples exhibited drop motion by coalescence rather than rolling. Larger coalesced drops of non-spherical shape with irregular triple line shapes span the surface pattern on all our surfaces, which suggests that the underlying pattern of the surface has no dominant effect on the behavior of the droplets on these surfaces.

  7. Analysis of Drugs of Abuse in Anonymously Collected Urine and Soil samples from a Music Festival in Scandinavia

    DEFF Research Database (Denmark)

    Mardal, Marie; Ramin, Pedram; Plósz, Benedek G.

    Aim: Pooled human urine and soil from urinating spots were collected anonymously at a Scandinavian music festival. Samples should be screened for drugs of abuse, particularly novel psychoactive substances (NPS), but also therapeutic drugs and ethanol. Methods: Twenty-one urine samples were...... be detected besides several therapeutic drugs: cocaine (9), MDMA (7), sildenafil (2), ketamine (1), amphetamine (1), and oxycodone (1). Conclusions: NPS were detected neither in urine nor in soil samples. This might be due to low concentrations based on their negligible consumption at the studied festival...

  8. Influence of Sampling Effort on the Estimated Richness of Road-Killed Vertebrate Wildlife

    Science.gov (United States)

    Bager, Alex; da Rosa, Clarissa A.

    2011-05-01

    Road-killed mammals, birds, and reptiles were collected weekly from highways in southern Brazil in 2002 and 2005. The objective was to assess variation in estimates of road-kill impacts on species richness produced by different sampling efforts, and to provide information to aid in the experimental design of future sampling. Richness observed in weekly samples was compared with sampling for different periods. In each period, the list of road-killed species was evaluated based on estimates the community structure derived from weekly samplings, and by the presence of the ten species most subject to road mortality, and also of threatened species. Weekly samples were sufficient only for reptiles and mammals, considered separately. Richness estimated from the biweekly samples was equal to that found in the weekly samples, and gave satisfactory results for sampling the most abundant and threatened species. The ten most affected species showed constant road-mortality rates, independent of sampling interval, and also maintained their dominance structure. Birds required greater sampling effort. When the composition of road-killed species varies seasonally, it is necessary to take biweekly samples for a minimum of one year. Weekly or more-frequent sampling for periods longer than two years is necessary to provide a reliable estimate of total species richness.

  9. [Comparison of the determination of cyclosporin-A in blood samples collected on filter paper and by the ordinary technique].

    Science.gov (United States)

    Azevedo, L S; Manrique, R; Sabbaga, E

    1995-01-01

    Monitoring cyclosporin-A (CsA) blood levels is of utmost importance for the rational use of this drug. Although many centers perform transplants, in Brazil there are few laboratories able to measure CsA blood levels. Therefore making blood samples reach the laboratory emerged as a problem. Collection of blood on filter paper has been a technique used for a long time in special cases. PURPOSE--To confirm the usefulness of measuring CsA blood levels in blood samples collected on filter paper and in the usual way. METHOD--We studied twenty renal cadaver kidney recipients who were receiving CsA, azathioprine and prednisone. Ninety five blood samples were collected and divided into two aliquots. One of them was sent routinely to one laboratory to perform whole blood CsA measurements. From the other aliquot, 20 microliters were pipetted on filter paper. When dried they were mailed to the other laboratory, where, after elution, CsA was measured. In both cases radioimmunoassay with polyclonal antibody was used. RESULTS--Linear correlation between both measurements revealed r = 0.81 with no statistical difference. CONCLUSION--The technique showed to be useful in clinical practice. In countries with continental size, as Brazil, it may be very helpful.

  10. [Sampling, storage and transport of biological materials collected from living and deceased subjects for determination of concentration levels of ethyl alcohol and similarly acting substances. A proposal of updating the blood and urine sampling protocol].

    Science.gov (United States)

    Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew

    2007-01-01

    The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.

  11. Analyses of Gas, Steam and Water Samples Collected in and Around Lassen Volcanic National Park, California, 1975-2002

    Science.gov (United States)

    Janik, Cathy J.; Bergfeld, D.

    2010-01-01

    This report contains physical and chemical data from gas, steam, and water samples collected between July 1975 and September 2002 from locations in and around Lassen Volcanic National Park, California. Data are compiled as tables in Excel spreadsheets and are organized by locale. Most data are keyed to 1 of 107 site codes that are shown on local- and regional-scale maps. Brief descriptions of terminology, sampling, and analytical methods are provided.

  12. Spatial scan statistics to assess sampling strategy of antimicrobial resistance monitoring programme

    DEFF Research Database (Denmark)

    Vieira, Antonio; Houe, Hans; Wegener, Henrik Caspar

    2009-01-01

    Pie collection and analysis of data on antimicrobial resistance in human and animal Populations are important for establishing a baseline of the occurrence of resistance and for determining trends over time. In animals, targeted monitoring with a stratified sampling plan is normally used. However...... sampled by the Danish Integrated Antimicrobial Resistance Monitoring and Research Programme (DANMAP), by identifying spatial Clusters of samples and detecting areas with significantly high or low sampling rates. These analyses were performed for each year and for the total 5-year study period for all...... by an antimicrobial monitoring program....

  13. Collection of Oral Fluids Using Cotton Ropes as a Sampling Method to Detect Foot-and-Mouth Disease Virus Infection in Pigs.

    Science.gov (United States)

    Vosloo, W; Morris, J; Davis, A; Giles, M; Wang, J; Nguyen, H T T; Kim, P V; Quach, N V; Le, P T T; Nguyen, P H N; Dang, H; Tran, H X; Vu, P P; Hung, V V; Le, Q T; Tran, T M; Mai, T M T; Le, Q T V; Singanallur, N B

    2015-10-01

    In high-density farming practices, it is important to constantly monitor for infectious diseases, especially diseases that have the potential to spread rapidly between holdings. Pigs are known to amplify foot-and-mouth disease (FMD) by excreting large amounts of virus, and it is therefore important to detect the virus quickly and accurately to minimize the spread of disease. Ropes were used to collect oral fluid samples from pigs, and each sample was compared to saliva samples collected from individual animals by detecting FMD virus RNA using real-time PCR. Two different experiments are described where groups of pigs were infected with different serotypes of FMD virus, either with or without vaccination, and unvaccinated pigs were kept in aerosol contact. The sensitivity of the rope sampling varied between 0.67 and 0.92, and the statistical agreement between this method and individual sampling ranged from substantial to moderate for the two different serotypes. The ease of collecting oral fluids using ropes together with the high sensitivity of subsequent FMD detection through PCR indicates that this could be a useful method to monitor pig populations for FMD virus infection. With further validation of the sensitivity of detection of FMD virus RNA, this can be a cost-effective, non-invasive diagnostic tool. © 2013 Blackwell Verlag GmbH.

  14. Evaluation of Equations for Predicting 24-Hour Urinary Sodium Excretion from Casual Urine Samples in Asian Adults.

    Science.gov (United States)

    Whitton, Clare; Gay, Gibson Ming Wei; Lim, Raymond Boon Tar; Tan, Linda Wei Lin; Lim, Wei-Yen; van Dam, Rob M

    2016-08-01

    The collection of 24-h urine samples for the estimation of sodium intake is burdensome, and the utility of spot urine samples in Southeast Asian populations is unclear. We aimed to assess the validity of prediction equations with the use of spot urine concentrations. A sample of 144 Singapore residents of Chinese, Malay, and Indian ethnicity aged 18-79 y were recruited from the Singapore Health 2 Study conducted in 2014. Participants collected urine for 24 h in multiple small bottles on a single day. To determine the optimal collection time for a spot urine sample, a 1-mL sample was taken from a random bottle collected in the morning, afternoon, and evening. Published equations and a newly derived equation were used to predict 24-h sodium excretion from spot urine samples. The mean ± SD concentration of sodium from the 24-h urine sample was 125 ± 53.4 mmol/d, which is equivalent to 7.2 ± 3.1 g salt. Bland-Altman plots showed good agreement at the group level between estimated and actual 24-h sodium excretion, with biases for the morning period of -3.5 mmol (95% CI: -14.8, 7.8 mmol; new equation) and 1.46 mmol (95% CI: -10.0, 13.0 mmol; Intersalt equation). A larger bias of 25.7 mmol (95% CI: 12.2, 39.3 mmol) was observed for the Tanaka equation in the morning period. The prediction accuracy did not differ significantly for spot urine samples collected at different times of the day or at a random time of day (P = 0.11-0.76). This study suggests that the application of both our own newly derived equation and the Intersalt equation to spot urine concentrations may be useful in predicting group means for 24-h sodium excretion in urban Asian populations. © 2016 American Society for Nutrition.

  15. Evaluation of some pollutant levels in environmental samples collected from the area of the new campus of Taif University.

    Science.gov (United States)

    Sharshar, Taher; Hassan, H Ebrahim; Arida, Hassan A; Aydarous, Abdulkadir; Bazaid, Salih A; Ahmed, Mamdouh A

    2013-01-01

    The levels of radioactivity and heavy metals in soil, plant and groundwater samples collected from the area of the new campus of Taif University, Saudi Arabia, and its neighbouring areas have been determined. High-resolution gamma-ray spectroscopy was used for radioactivity measurements, and inductively coupled plasma atomic emission spectroscopy was used to determine the concentration of heavy metals. The means of (226)Ra, (228)Ra and (40)K concentrations in water samples collected from four wells were found to be 0.13 ± 0.03, 0.05 ± 0.03 and 1.3 ± 0.5 Bq l(-1), respectively. The means of (238)U, (226)Ra, (228)Ra ((232)Th for soil samples) and (40)K concentrations in wild plant and soil samples were found to be 3.7 ± 4.1, 8.8 ± 11.6, 3.8 ± 2.9 and 1025 ± 685, and 8.6 ± 3.4, 12.8 ± 3.4, 16.6 ± 7.1 and 618 ± 82 Bq kg(-1) dry weight (DW), respectively. The (137)Cs of artificial origin was also detected in soil samples with a mean concentration of 3.8 ± 2.2 Bq kg(-1) DW. Evaluating the results, it can be concluded that the concentrations of (238)U, (226)Ra, (232)Th and (40)K in soil samples fall within the world average. Furthermore, 19 trace and major elements in groundwater samples and 22 elements in soil and plant samples were determined. The sampling locations of soil can be classified into three groups (relatively high, medium and low polluted) according to their calculated metal pollution index using the contents of trace and major elements. A cluster analysis of the contents of radioactivity and trace element contents in soil samples shows the presence of two main distinct clusters of sampling locations.

  16. Automatic collection of bovine blood samples | Hale | South African ...

    African Journals Online (AJOL)

    A technique is described which allows automatic collection of jugular venous blood from tethered cows. In this system, blood is pumped continuously from an intravenous cannula which has a double lumen while an anticoagulant is pumped through the second opening. Diluted blood is collected in a fraction collector which ...

  17. Characteristic of selected frequency luminescence for samples collected in deserts north to Beijing

    International Nuclear Information System (INIS)

    Li Dongxu; Wei Mingjian; Wang Junping; Pan Baolin; Zhao Shiyuan; Liu Zhaowen

    2009-01-01

    Surface sand samples were collected in eight sites of the Horqin and Otindag deserts located in north to Beijing. BG2003 luminescence spectrograph was used to analyze the emitted photons and characteristic spectra of the selected frequency luminescence were obtained. It was found that high intensities of emitted photons stimulated by heat from 85 degree C-135 degree C and 350 degree C-400 degree C. It belong to the traps of 4.13 eV (300 nm), 4.00 eV (310 nm), 3.88 eV (320 nm) and 2.70 eV (460 nm), and the emitted photons belong to traps of 4.00 eV (310 nm), 3.88 eV (320 nm) and 2.70 eV (460 nm) were stimulated by green laser. And sand samples of the eight sites can respond to the increase of definite radiological dose at each wavelength, which is the characteristic spectrum to provide radiation dosimetry basis for dating. There are definite district characteristic in their characteristic spectra. (authors)

  18. Uranium analysis in some food samples collected from Bathinda area of Punjab, India

    Science.gov (United States)

    Kumar, Mukesh; Prasher, Sangeeta; Singh, Surinder

    2009-07-01

    To strengthen the radiation protection infrastructure in Bathinda, the uranium concentration in daily diet of the residents has been measured and its associated radiation risks were estimated for the adult population. Food samples were collected from major cancer prone areas of the district, from which daily diets were prepared. These diet samples were analyzed using fission track technique. The measured values of the uranium content were found to vary from 0.38 mBq/g in mustard seeds to 4.60 mBq/g in wheat. In case of milk the uranium content is found to vary from 28.57-213.36 mBq/ℓ with mean concentration of 61.35 mBq/ℓ. This leads to a daily dietary intake of 0.90 Bq/day. The measured value of 0.90 Bq d-1, contributes to 1.12 mSv to the cumulative effective dose to the population. This dose is much large than the International Commission for Radiological Protection (ICRP) annual effective dose limit of 1 mSv for the general public [1]. Therefore, it would pose significant health hazard.

  19. Neutron activation analysis for environmental sample in Thailand

    International Nuclear Information System (INIS)

    Busamongkol, Arporn; Nouchpramool, Sunun; Bunprapob, Supamatthree; Sumitra, Tatchai

    2003-01-01

    Neutron Activation Analysis has been applied for the trace elements analysis in environmental samples. Thirty three samples of airborne particulate were collected every week at Ongkharak Nuclear Research Center (ONRC) during the period of June 1998 to March 1999. The Ti, I, Mg, Na, V, K, Cl, Al, Mn, Ca, As, Sm, Sb, Br, La, Ce, Th, Cr, Cs, Sc, Rb, Fe, Zn and Co were analyzed by Neutron Activation Analysis utilizing 2 MW TRIGA MARK III research reactor. The certified reference materials 1632a and 1633a from National Bureau of Standard were select as standard. (author)

  20. Soil Gas Sample Handling: Evaluation of Water Removal and Sample Ganging

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, Brad G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Abrecht, David G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hayes, James C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Mendoza, Donaldo P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-10-31

    Soil gas sampling is currently conducted in support of Nuclear Test Ban treaty verification. Soil gas samples are collected and analyzed for isotopes of interest. Some issues that can impact sampling and analysis of these samples are excess moisture and sample processing time. Here we discuss three potential improvements to the current sampling protocol; a desiccant for water removal, use of molecular sieve to remove CO2 from the sample during collection, and a ganging manifold to allow composite analysis of multiple samples.

  1. Petrographic description of calcite/opal samples collected on field trip of December 5-9, 1992. Special report No. 7

    International Nuclear Information System (INIS)

    Hill, C.A.; Schluter, C.M.

    1993-06-01

    This study is part of the research program of the Yucca Mountain Project intended to provide the State of Nevada with a detailed analysis and assessment of the water-deposited minerals of Yucca Mountain and adjacent regions. Forty-three separate stops were made and 203 samples were collected during the five days of the field trip. This report describes petrographic observations made on the calcite/opal samples

  2. Collection of preputial material by scraping and aspiration for the diagnosis of Tritrichomonas foetus in bulls

    Directory of Open Access Journals (Sweden)

    P.C. Irons

    2002-07-01

    Full Text Available Two trials were carried out to assess the diagnostic sensitivity and practicability of preputial scraping as a method of collecting preputial material from bulls infected with Tritrichomonas foetus. In the 1st trial, preputial material was collected by simultaneous scraping and aspiration from 3 infected and 1 uninfected bull 10 times over a 5-week period. In the 2nd trial, samples from 5 infected bulls were collected by both sheath washing and scraping on 6 occasions, while 8 uninfected animals were sampled 3 times. Samples were cultured using a modified Trichomonas culture medium (Oxoid. In the first trial, 29 of 30 samples from infected bulls were found to be positive. In the second trial, 83 % of samples collected by both methods tested positive. In neither trial were any samples from the control bulls found to be positive. Scraping was found to be quick and safe, and offered advantages over preputial washing in that urine contamination was easily avoided, samples were smaller and more concentrated and contamination was reduced. It may, however, be subject to greater operator variability than sheath washing. It is concluded that preputial scraping is as effective as washing and represents a suitable alternative for the collection of material for direct examination and culture of Tritrichomonas foetus.

  3. An Analysis of Light Periods of BL Lac Object S5 0716+714 with the MUSIC Algorithm

    Science.gov (United States)

    Tang, Jie

    2012-07-01

    The multiple signal classification (MUSIC) algorithm is introduced to the estimation of light periods of BL Lac objects. The principle of the MUSIC algorithm is given, together with a testing on its spectral resolution by using a simulative signal. From a lot of literature, we have collected a large number of effective observational data of the BL Lac object S5 0716+714 in the three optical wavebands V, R, and I from 1994 to 2008. The light periods of S5 0716+714 are obtained by means of the MUSIC algorithm and average periodogram algorithm, respectively. It is found that there exist two major periodic components, one is the period of (3.33±0.08) yr, another is the period of (1.24±0.01) yr. The comparison of the performances of periodicity analysis of two algorithms indicates that the MUSIC algorithm has a smaller requirement on the sample length, as well as a good spectral resolution and anti-noise ability, to improve the accuracy of periodicity analysis in the case of short sample length.

  4. Quantized gauge invariant periodic TDHF solutions

    International Nuclear Information System (INIS)

    Kan, K.-K.; Griffin, J.J.; Lichtner, P.C.; Dworzecka, M.

    1979-01-01

    Time-dependent Hartree-Fock (TDHF) is used to study steady state large amplitude nuclear collective motions, such as vibration and rotation. As is well known the small amplitude TDHF leads to the RPA equation. The analysis of periodicity in TDHF is not trivial because TDHF is a nonlinear theory and it is not known under what circumstances a nonlinear theory can support periodic solutions. It is also unknown whether such periodic solution, if they exist, form a continuous or a discrete set. But, these properties may be important in obtaining the energy spectrum of the collective states from the TDHF description. The periodicity and Gauge Invariant Periodicity of solutions are investigated for that class of models whose TDHF solutions depend on time through two parameters. In such models TDHF supports a continuous family of periodic solutions, but only a discrete subset of these is gauge invariant. These discrete Gauge Invariant Periodic solutions obey the Bohr-Summerfeld quantization rule. The energy spectrum of the Gauge Invariant Periodic solutions is compared with the exact eigenergies in one specific example

  5. Adrenaline (epinephrine) dosing period and survival after in-hospital cardiac arrest: a retrospective review of prospectively collected data.

    Science.gov (United States)

    Warren, Sam A; Huszti, Ella; Bradley, Steven M; Chan, Paul S; Bryson, Chris L; Fitzpatrick, Annette L; Nichol, Graham

    2014-03-01

    Expert guidelines for treatment of cardiac arrest recommend administration of adrenaline (epinephrine) every three to five minutes. However, the effects of different dosing periods of epinephrine remain unclear. We sought to evaluate the association between epinephrine average dosing period and survival to hospital discharge in adults with an in-hospital cardiac arrest (IHCA). We performed a retrospective review of prospectively collected data on 20,909 IHCA events from 505 hospitals participating in the Get With The Guidelines-Resuscitation (GWTG-R) quality improvement registry. Epinephrine average dosing period was defined as the time between the first epinephrine dose and the resuscitation endpoint, divided by the total number of epinephrine doses received subsequent to the first epinephrine dose. Associations with survival to hospital discharge were assessed by using generalized estimating equations to construct multivariable logistic regression models. Compared to a referent epinephrine average dosing period of 4 to <5 min per dose, survival to hospital discharge was significantly higher in patients with the following epinephrine average dosing periods: for 6 to <7 min/dose, adjusted odds ratio [OR], 1.41 (95%CI: 1.12, 1.78); for 7 to <8 min/dose, adjusted OR, 1.30 (95%CI: 1.02, 1.65); for 8 to <9 min/dose, adjusted OR, 1.79 (95%CI: 1.38, 2.32); for 9 to <10 min/dose, adjusted OR, 2.17 (95%CI: 1.62, 2.92). This pattern was consistent for both shockable and non-shockable cardiac arrest rhythms. Less frequent average epinephrine dosing than recommended by consensus guidelines was associated with improved survival of in-hospital cardiac arrest. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  6. 78 FR 69095 - Agency Information Collection Activities; Proposed Collection; Comment Request; Food Canning...

    Science.gov (United States)

    2013-11-18

    ...] Agency Information Collection Activities; Proposed Collection; Comment Request; Food Canning... or we) is extending the comment period for the information collection entitled ``Food Canning... a proposed collection of information related to ``Food Canning Establishment Registration, Process...

  7. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF URINE SAMPLES FOR METALS AND PESTICIDES ANALYSIS (UA-F-20.1)

    Science.gov (United States)

    The purpose of this SOP is to guide the collection, storage, and shipment of urine samples collected. This SOP provides a brief description of sample, collection, preservation, storage, shipping, and custody procedures. This procedure was followed to ensure consistent data retri...

  8. Tank 241-U-104 headspace gas and vapor characterization results from samples collected on July 16, 1996

    International Nuclear Information System (INIS)

    Pool, K.H.; Evans, J.C.; Hayes, J.C.; Mitroshkov, A.V.; Edwards, J.A.; Julya, J.L.; Thornton, B.M.; Fruchter, J.S.; Silvers, K.L.

    1997-08-01

    This report presents the results from analyses of samples taken from the headspace of waste storage tank 241-U-104 (Tank U-104) at the Hanford Site in Washington State. Tank headspace samples collected by Westinghouse Hanford Company (WHC) were analyzed by Pacific Northwest National Laboratory (PNNL) to determine headspace concentrations of selected non-radioactive analytes. Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Vapor concentrations from sorbent trap samples are based on measured sample volumes provided by WHC. No analytes were determined to be above the immediate notification limits specified by the sampling and analysis plan. None of the flammable constituents were present at concentrations above the analytical instrument detection limits. Total headspace flammability was estimated to be <0.108% of the lower flammability limit. Average measured concentrations of targeted gases, inorganic vapors, and selected organic vapors are provided in a table. A summary of experimental methods, including sampling methodology, analytical procedures, and quality assurance and control methods are presented in Section 2.0. Detailed descriptions of the analytical results are provided in Section 3.0

  9. Supplementing electronic health records through sample collection and patient diaries: A study set within a primary care research database.

    Science.gov (United States)

    Joseph, Rebecca M; Soames, Jamie; Wright, Mark; Sultana, Kirin; van Staa, Tjeerd P; Dixon, William G

    2018-02-01

    To describe a novel observational study that supplemented primary care electronic health record (EHR) data with sample collection and patient diaries. The study was set in primary care in England. A list of 3974 potentially eligible patients was compiled using data from the Clinical Practice Research Datalink. Interested general practices opted into the study then confirmed patient suitability and sent out postal invitations. Participants completed a drug-use diary and provided saliva samples to the research team to combine with EHR data. Of 252 practices contacted to participate, 66 (26%) mailed invitations to patients. Of the 3974 potentially eligible patients, 859 (22%) were at participating practices, and 526 (13%) were sent invitations. Of those invited, 117 (22%) consented to participate of whom 86 (74%) completed the study. We have confirmed the feasibility of supplementing EHR with data collected directly from patients. Although the present study successfully collected essential data from patients, it also underlined the requirement for improved engagement with both patients and general practitioners to support similar studies. © 2017 The Authors. Pharmacoepidemiology & Drug Safety published by John Wiley & Sons Ltd.

  10. Optimizing detection of noble gas emission at a former UNE site: sample strategy, collection, and analysis

    Science.gov (United States)

    Kirkham, R.; Olsen, K.; Hayes, J. C.; Emer, D. F.

    2013-12-01

    Underground nuclear tests may be first detected by seismic or air samplers operated by the CTBTO (Comprehensive Nuclear-Test-Ban Treaty Organization). After initial detection of a suspicious event, member nations may call for an On-Site Inspection (OSI) that in part, will sample for localized releases of radioactive noble gases and particles. Although much of the commercially available equipment and methods used for surface and subsurface environmental sampling of gases can be used for an OSI scenario, on-site sampling conditions, required sampling volumes and establishment of background concentrations of noble gases require development of specialized methodologies. To facilitate development of sampling equipment and methodologies that address OSI sampling volume and detection objectives, and to collect information required for model development, a field test site was created at a former underground nuclear explosion site located in welded volcanic tuff. A mixture of SF-6, Xe127 and Ar37 was metered into 4400 m3 of air as it was injected into the top region of the UNE cavity. These tracers were expected to move towards the surface primarily in response to barometric pumping or through delayed cavity pressurization (accelerated transport to minimize source decay time). Sampling approaches compared during the field exercise included sampling at the soil surface, inside surface fractures, and at soil vapor extraction points at depths down to 2 m. Effectiveness of various sampling approaches and the results of tracer gas measurements will be presented.

  11. Mutagenicity of drinking water sampled from the Yangtze River and Hanshui River (Wuhan section) and correlations with water quality parameters.

    Science.gov (United States)

    Lv, Xuemin; Lu, Yi; Yang, Xiaoming; Dong, Xiaorong; Ma, Kunpeng; Xiao, Sanhua; Wang, Yazhou; Tang, Fei

    2015-03-31

    A total of 54 water samples were collected during three different hydrologic periods (level period, wet period, and dry period) from Plant A and Plant B (a source for Yangtze River and Hanshui River water, respectively), and several water parameters, such as chemical oxygen demand (COD), turbidity, and total organic carbon (TOC), were simultaneously analyzed. The mutagenicity of the water samples was evaluated using the Ames test with Salmonella typhimurium strains TA98 and TA100. According to the results, the organic compounds in the water were largely frame-shift mutagens, as positive results were found for most of the tests using TA98. All of the finished water samples exhibited stronger mutagenicity than the relative raw and distribution water samples, with water samples collected from Plant B presenting stronger mutagenic strength than those from Plant A. The finished water samples from Plant A displayed a seasonal-dependent variation. Water parameters including COD (r = 0.599, P = 0.009), TOC (r = 0.681, P = 0.02), UV254 (r = 0.711, P = 0.001), and total nitrogen (r = 0.570, P = 0.014) exhibited good correlations with mutagenicity (TA98), at 2.0 L/plate, which bolsters the argument of the importance of using mutagenicity as a new parameter to assess the quality of drinking water.

  12. Reproduction in female copperhead snakes (Agkistrodon contortrix): plasma steroid profiles during gestation and post-birth periods.

    Science.gov (United States)

    Smith, Charles F; Schuett, Gordon W; Hoss, Shannon K

    2012-04-01

    We investigated levels of plasma progesterone (P4), 17β-estradiol (E2), testosterone (T), and corticosterone (CORT) during gestation and post-birth periods in wild-collected female copperhead snakes (Viperidae; Agkistrodon contortrix). We also sought to determine whether CORT levels at (or near) birth dramatically increase and were correlated with duration of labor and litter size. Specifically, pregnant subjects (N = 14) were collected during early- to mid-gestation, held in the laboratory, and repeatedly bled to obtain plasma for steroid analyses. Progesterone showed significant changes during gestation, with the highest levels at the onset of sampling (circa 50 days prior to birth); P4 progressively declined up to parturition, and basal levels were observed thereafter. At the onset of sampling, E2 was at peak levels and fell sharply at circa 30 days prior to birth, a trend observed throughout the post-birth sampling period. Throughout the entire sampling period, T was undetectable. Although CORT showed no significant changes during gestation and several days following parturition, there was a highly significant peak at the time of birth. Our findings mirror the results of previous studies on pregnancy and steroid hormones of other live-bearing snakes, lizards, and mammals. As expected, there was a significant relationship between duration of labor and litter size; however, although levels of CORT did not achieve significance, there was a positive trend with litter size. We suggest that elevation of CORT at birth is involved in the mobilization and regulation of energy stores necessary for the physiological process of parturition and as a possible mechanism to trigger birth.

  13. Design of the CERN MEDICIS Collection and Sample Extraction System

    CERN Document Server

    Brown, Alexander

    MEDICIS is a new facility at CERN ISOLDE that aims to produce radio-isotopes for medical research. Possible designs for the collection and transport system for the collection of radio-isotopes was investigated. A system using readily available equipment was devised with the the aim of keeping costs to a minimum whilst maintaining the highest safety standards. FLUKA, a Monte Carlo radiation transport code, was used to simulate the radiation from the isotopes to be collected. Of the isotopes to be collected 44Sc was found to give the largest dose by simulating the collection of all isotopes of interest to CERN’s MEDICIS facility, for medical research. The simulations helped guide the amount of shielding used in the final design. Swiss Regulations stipulating allowed activity level of individual isotopes was also considered within the body of the work.

  14. Genetic Sample Inventory

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This database archives genetic tissue samples from marine mammals collected primarily from the U.S. east coast. The collection includes samples from field programs,...

  15. Predictive monitoring and diagnosis of periodic air pollution in a subway station.

    Science.gov (United States)

    Kim, YongSu; Kim, MinJung; Lim, JungJin; Kim, Jeong Tai; Yoo, ChangKyoo

    2010-11-15

    The purpose of this study was to develop a predictive monitoring and diagnosis system for the air pollutants in a subway system using a lifting technique with a multiway principal component analysis (MPCA) which monitors the periodic patterns of the air pollutants and diagnoses the sources of the contamination. The basic purpose of this lifting technique was to capture the multivariate and periodic characteristics of all of the indoor air samples collected during each day. These characteristics could then be used to improve the handling of strong periodic fluctuations in the air quality environment in subway systems and will allow important changes in the indoor air quality to be quickly detected. The predictive monitoring approach was applied to a real indoor air quality dataset collected by telemonitoring systems (TMS) that indicated some periodic variations in the air pollutants and multivariate relationships between the measured variables. Two monitoring models--global and seasonal--were developed to study climate change in Korea. The proposed predictive monitoring method using the lifted model resulted in fewer false alarms and missed faults due to non-stationary behavior than that were experienced with the conventional methods. This method could be used to identify the contributions of various pollution sources. Copyright © 2010 Elsevier B.V. All rights reserved.

  16. Ambient krypton-85 air sampling at Hanford

    International Nuclear Information System (INIS)

    Trevathan, M.S.; Price, K.R.

    1985-01-01

    In the fall of 1982, the Environmental Evaluations Section of Pacific Northwest Laboratory (PNL) initiated a network of continuous 85 Kr air samplers located on and around the Hanford Site. This effort was in response to the resumption of operations at a nuclear fuel reprocessing plant located onsite where 85 Kr was to be released during fuel dissolution. Preoperational data were collected using noble gas samplers designed by the Environmental Protection Agency-Las Vegas (EPA-LV). The samplers functioned erratically resulting in excessive maintenance costs and prompted a search for a new sampling system. State-of-the-art 85 Dr sampling methods were reviewed and found to be too costly, too complex and inappropriate for field application, so a simple bag collection system was designed and field tested. The system is composed of a reinforced, heavy plastic bag, connected to a variable flow pump and housed in a weatherproof enclosure. At the end of the four week sampling period the air in the bag is transferred by a compressor into a pressure tank for easy transport to the laboratory for analysis. After several months of operation, the air sampling system has proven its reliability and sensitivity to ambient levels of 85 Kr

  17. Ambient krypton-85 air sampling at Hanford

    International Nuclear Information System (INIS)

    Trevathan, M.S.; Price, K.R.

    1984-10-01

    In the fall of 1982, the Environmental Evaluations Section of Pacific Northwest Laboratory (PNL) initiated a network of continuous krypton-85 air samplers located on and around the Hanford Site. This effort was in response to the resumption of operations at a nuclear fuel reprocessing plant located onsite where krypton-85 was to be released during fuel dissolution. Preoperational data were collected using noble gas samplers designed by the Environmental Protection Agency-Las Vegas (EPA-LV). The samplers functioned erratically resulting in excessive maintenance costs and prompted a search for a new sampling system. State of the art krypton-85 sampling methods were reviewed and found to be too costly, too complex and inappropriate for field application, so a simple bag collection system was designed and field tested. The system is composed of a reinforced, heavy plastic bag, connected to a variable flow pump and housed in a weatherproof enclosure. At the end of the four week sampling period the air in the bag is transferred by a compressor into a pressure tank for easy transport to the laboratory for analysis. After several months of operation, the air sampling system has proven its reliability and sensitivity to ambient levels of krypton-85. 3 references, 3 figures, 1 table

  18. Acceptability of study procedures (self-collected introital swabs, blood draws and stool sample collection) by students 10-16 years for an HPV vaccine effectiveness study: a pilot study.

    Science.gov (United States)

    Nakalembe, Miriam; Mutyaba, Twaha; Mirembe, Florence

    2016-03-16

    A cohort study was planned to evaluate vaccine immunogenicity and effect of malaria and helminth co-infections on the bivalent Human papilloma virus (HPV) vaccine. The study would involve self collected introital swabs, blood draws and stool sample collection. We therefore conducted a pilot study to assess the acceptability of these procedures among the students and their parents. A cross-sectional study among forty four students from two purposively selected primary schools of Western Uganda. Exit interviews and two focus group discussions (FGD) (for parents) were conducted. Acceptability was measured by willingness to undergo the procedures again, recommending the procedures to others as well as proportion of introital swabs positive for β globulin. FGD determined acceptability of the parents and explored opinions and perceptions that would influence their decisions. HPV-16/18 and β globulin deoxyribonucleic acid (DNA) were analysed using a polymerase chain reaction (PCR) kit. All the students (100%) in the study were willing to provide a self- collected introital swab and a stool sample as well as recommending their friends while (86.3%) were willing for blood draws. There were 40/44 (90.1%) self collected introital swabs that had positive result for human β globulin though none of them was positive for HPV-16/18. In the FGD, it emerged that parents concerns were on the blood draws and introital swab collection which were addressed. The study procedures were highly acceptable among this study population of students and their parents. Follow-up to assess HPV vaccine effectiveness and factors that may influence the vaccine in this age group is feasible.

  19. β-trace protein as a diagnostic marker for perilymphatic fluid fistula: a prospective controlled pilot study to test a sample collection technique.

    Science.gov (United States)

    Bachmann-Harildstad, Gregor; Stenklev, Niels Christian; Myrvoll, Elin; Jablonski, Greg; Klingenberg, Olav

    2011-01-01

    The diagnosis of perilymphatic fluid (PLF) fistula is still challenging. Perilymphatic fluid fistula is one possible complication after stapedotomy or cochlear implant surgery. We have performed a prospective diagnostic pilot study to further investigate β-trace protein (β-TP) as a marker for PLF fistula. In this pilot study, we tested the sensitivity of the β-TP marker using a simple method for sample collection from the tympanic cavity. Prospective controlled diagnostic study. Two-center tertiary referral hospitals. A total of 35 adult patients undergoing ear surgery were included. Subjects were divided into 2 groups: 1) 19 patients undergoing stapedotomy were investigated for PLF fistula in samples obtained from the tympanic cavity and 2) 16 patients undergoing myringoplasty were investigated for PLF fistula in samples from the tympanic cavity. This group served as the control. Mean age +/- SD at surgery was 49.9 +/- 8.0 years in the study group and 39.69 +/- 15.47 years in the control group. β-Trace protein (prostaglandin D synthase) in tympanic cavity samples and serum samples was analyzed. The samples were collected by gradually filling the tympanic cavity with 100 to 200 μl sodium chloride and by immediately collecting a volume of 60 to 100 μl in a mucus specimen set container. The concentration of β-TP was quantified using laser nephelometry. The median β-TP in the study group was 0.8 mg/L (range, 0.05-4.5 mg/L). In the control group, the median β-TP value was 0.16 mg/L (range, 0.01-0.36 mg/L). Thirty-five percent of the values in the study group were below the highest value in the negative control group. The β-TP values of the tympanic cavity samples were significantly higher in the study group than in controls (p = 0.0001). The serum values were 0.55 +/- 0.18 and 0.53 +/- 0.11 mg/L, respectively. It may be feasible to test for PLF fistula using β-TP in samples from the tympanic cavity. Our results, however, suggest a relative low diagnostic

  20. Integrity of the Human Faecal Microbiota following Long-Term Sample Storage.

    Directory of Open Access Journals (Sweden)

    Elahe Kia

    Full Text Available In studies of the human microbiome, faecal samples are frequently used as a non-invasive proxy for the study of the intestinal microbiota. To obtain reliable insights, the need for bacterial DNA of high quality and integrity following appropriate faecal sample collection and preservation steps is paramount. In a study of dietary mineral balance in the context of type 2 diabetes (T2D, faecal samples were collected from healthy and T2D individuals throughout a 13-day residential trial. These samples were freeze-dried, then stored mostly at -20°C from the trial date in 2000/2001 until the current research in 2014. Given the relative antiquity of these samples (~14 years, we sought to evaluate DNA quality and comparability to freshly collected human faecal samples. Following the extraction of bacterial DNA, gel electrophoresis indicated that our DNA extracts were more sheared than extracts made from freshly collected faecal samples, but still of sufficiently high molecular weight to support amplicon-based studies. Likewise, spectrophotometric assessment of extracts revealed that they were of high quality and quantity. A subset of bacterial 16S rRNA gene amplicons were sequenced using Illumina MiSeq and compared against publicly available sequence data representing a similar cohort analysed by the American Gut Project (AGP. Notably, our bacterial community profiles were highly consistent with those from the AGP data. Our results suggest that when faecal specimens are stored appropriately, the microbial profiles are preserved and robust to extended storage periods.

  1. Sampling and analysis of 100 Area springs

    International Nuclear Information System (INIS)

    1992-02-01

    This report is submitted in fulfillment of Hanford Federal Facility Agreement and Consent Order Milestone M-30-01, submit a report to EPA and Ecology evaluating the impact to the Columbia River from contaminated springs and seeps as described in the operable unit work plans listed in M-30-03. Springs, seeps, sediments, and the Columbia River were sampled for chemical and radiological analyses during the period September 16 through October 21, 1991. A total of 26 locations were sampled. Results of these analyses show that radiological and nonradiological contaminants continue to enter the Columbia River from the retired reactor areas of the 100 Area via the springs. The primary contaminants in the springs are strontium-90, tritium, and chromium. These contaminants were detected in concentrations above drinking water standards. Analysis of total organic carbon were run on all water samples collected; there is no conclusive evidence that organic constituents are entering the river through the springs. Total organic carbon analyses were generally higher for the surface water than for the springs. The results of this study will be used to develop a focused, yet flexible, long-term spring sampling program. Analysis of Columbia River water samples collected at the Hanford Townsite (i.e., downstream of the reactor areas) did not detect any Hanford-specific contaminants

  2. Collectively-enhanced optomechanical coupling in periodic arrays of scatterers

    DEFF Research Database (Denmark)

    Xuereb, André; Genes, Claudiu; Dantan, Aurelien Romain

    2013-01-01

    in linear optomechanical coupling strengths between the cavity field and collective motional modes of the array that may be several orders of magnitude larger than is possible with an equivalent reflective ensemble. We describe and interpret these effects in detail and investigate the nature of the scaling...... laws of the coupling strengths for the different transmissive points in various regimes....

  3. Collective Security

    DEFF Research Database (Denmark)

    Galster, Kjeld

    in worldwide market conditions left perceptible ripples in Danish economy, budget discussions grew in importance over this period. The pacifist stance entailed disinclination to accept that the collective security concept and international treaties and accords signed by Denmark should necessitate credible...... and other international treaties provided arguments for adjusting the foreign and security policy ambitions, and since the general flux in worldwide market conditions left perceptible ripples in Danish economy, budget discussions grew in importance over this period. The pacifist stance entailed......Collective Security: National Egotism (Abstract) In Danish pre-World War I defence debate the notion of collective security is missing. During the early years of the 19th century, the political work is influenced by a pervasive feeling of rising tension and danger on the continent of Europe...

  4. Removal of arsenic from ground water samples collected from West Bengal, India

    International Nuclear Information System (INIS)

    Ajith, Nicy; Swain, K.K.; Dalvi, Aditi A.; Verma, R.

    2015-01-01

    Arsenic contamination in ground water is one of the major concerns in many parts of the world including Bangladesh and India. Considering the high toxicity of arsenic, World Health Organization (WHO) has set a provisional guideline value of 10 μg L -1 for arsenic in drinking water. Several methods have been adopted for the removal of arsenic from drinking water. Most of the methods fail to remove As(III), the most toxic form of arsenic. An extra oxidative treatment step is essential for effective removal of total arsenic. Manganese dioxide (MnO 2 ) oxidizes As(III) to As(V). Removal of arsenic from water using manganese dioxide has been reported. During this work, removal of arsenic from ground water samples collected from arsenic contaminated area of West Bengal, India were carried out using MnO 2

  5. Effective sample labeling

    International Nuclear Information System (INIS)

    Rieger, J.T.; Bryce, R.W.

    1990-01-01

    Ground-water samples collected for hazardous-waste and radiological monitoring have come under strict regulatory and quality assurance requirements as a result of laws such as the Resource Conservation and Recovery Act. To comply with these laws, the labeling system used to identify environmental samples had to be upgraded to ensure proper handling and to protect collection personnel from exposure to sample contaminants and sample preservatives. The sample label now used as the Pacific Northwest Laboratory is a complete sample document. In the event other paperwork on a labeled sample were lost, the necessary information could be found on the label

  6. Formation of the Periotic Space During the Early Fetal Period in Humans.

    Science.gov (United States)

    Ishikawa, Aoi; Ohtsuki, Sae; Yamada, Shigehito; Uwabe, Chigako; Imai, Hirohiko; Matsuda, Tetsuya; Takakuwa, Tetsuya

    2018-04-01

    The inner ear is a very complicated structure, composed of a bony labyrinth (otic capsule; OC), membranous labyrinth, with a space between them, named the periotic labyrinth or periotic space. We investigated how periotic tissue fluid spaces covered the membranous labyrinth three-dimensionally, leading to formation of the periotic labyrinth encapsulated in the OC during human fetal development. Digital data sets from magnetic resonance images and phase-contrast X-ray tomography images of 24 inner ear organs from 24 human fetuses from the Kyoto Collection (fetuses in trimesters 1 and 2; crown-rump length: 14.4-197 mm) were analyzed. The membranous labyrinth was morphologically differentiated in samples at the end of the embryonic period (Carnegie stage 23), and had grown linearly to more than eight times in size during the observation period. The periotic space was first detected at the 35-mm samples, around the vestibule and basal turn of the cochlea, which elongated rapidly to the tip of the cochlea and semicircular ducts, successively, and almost covered the membranous labyrinth at the 115-mm CRL stage or later. In those samples, several ossification centers were detected around the space. This article thus demonstrated that formation of the membranous labyrinth, periotic space (labyrinth), and ossification of the OC occurs successively, according to an intricate timetable. Anat Rec, 301:563-570, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  7. Dried Blood Spot Collection of Health Biomarkers to Maximize Participation in Population Studies

    Science.gov (United States)

    Ostler, Michael W.; Porter, James H.; Buxton, Orfeu M.

    2014-01-01

    Biomarkers are directly-measured biological indicators of disease, health, exposures, or other biological information. In population and social sciences, biomarkers need to be easy to obtain, transport, and analyze. Dried Blood Spots meet this need, and can be collected in the field with high response rates. These elements are particularly important in longitudinal study designs including interventions where attrition is critical to avoid, and high response rates improve the interpretation of results. Dried Blood Spot sample collection is simple, quick, relatively painless, less invasive then venipuncture, and requires minimal field storage requirements (i.e. samples do not need to be immediately frozen and can be stored for a long period of time in a stable freezer environment before assay). The samples can be analyzed for a variety of different analytes, including cholesterol, C-reactive protein, glycosylated hemoglobin, numerous cytokines, and other analytes, as well as provide genetic material. DBS collection is depicted as employed in several recent studies. PMID:24513728

  8. Sampling technique for collection of expired COsub(2) in studies using naturally labelled sup(13)C in calves

    International Nuclear Information System (INIS)

    Chevalier, R.; Pelletier, G.; Gagnon, M.

    1984-01-01

    Natural isotopic labelling of animal metabolic processes presents great advantages over the use of artificially enriched compounds. These advantages include the use of natural diets, low cost and easiness of handling, sampling and disposal. Changes in the sup(13)C/sup(12)C ratio of expired COsub(2) after ingestion of a test meal containing a variable proportion of Csub(3) and/or Csub(4) plant-derived products permits measurements of the immediate oxidation of dietary carbohydrates. A breathing device for collection of expired COsub(2) and purification techniques are described. The breath-sampling device is composed of a polypropylene enclosure and a rubber bag. The rubber bag is blown up by the animal and a sample of the expired gas is transferred to a sampling glass holder in which a vacuum had been previously achieved. Sample purification of expired COsub(2) is done by differential freezing

  9. Laboratory Sampling Guide

    Science.gov (United States)

    2012-05-11

    environment, and by ingestion of foodstuffs that have incorporated C-14 by photosynthesis . Like tritium, C-14 is a very low energy beta emitter and is... bacterial growth and to minimize development of solids in the sample. • Properly identify each sample container with name, SSN, and collection start and...sampling in the same cardboard carton. The sample may be kept cool or frozen during collection to control odor and bacterial growth. • Once

  10. Microbial diversity in firework chemical exposed soil and water samples collected in Virudhunagar district, Tamil Nadu, India.

    Science.gov (United States)

    Dhasarathan, P; Theriappan, P; Ashokraja, C

    2010-03-01

    Microbial diversity of soil and water samples collected from pyrochemicals exposed areas of Virdhunagar district (Tamil Nadu, India) was studied. Soil and water samples from cultivable area, waste land and city area of the same region were also studied for a comparative acount. There is a remarkable reduction in total heterotrophic bacterial population (THB) in pyrochemicals exposed soil and water samples (42 × 10(4) CFU/g and 5.6 × 10(4) CFU/ml respectively), compared to the THB of cultivable area soil and water samples (98 × 10(7) CFU/g and 38.6 × 10(7) CFU/ml). The generic composition the THB of the pyrochemicals exposed samples too exhibited considerable change compared to other samples. Pseudomonas sp. was the predominant one (41.6%) followed by Achromobacter sp. (25%) in pyrochemical exposed soil and Pseudomonas sp. was the predominant one (25%) in pyrochemical exposed water samples followed by Bacillus sp. (25%) and Micrococcus sp. (16.6%). It was observed that Cornybacterium sp. and Micrococcus sp. were absent completely in pyrochemical exposed soil and Achromobacter sp. was missing in the pyrochemical exposed water samples, which were present in the other samples. The outcome of this study clearly demonstrates that pollutants such as chemicals used in pyrotechniques affect the microbial biodiversity and suitable measures have to be taken to control the pollution level and to save biodiversity.

  11. Prevalence of antibiotic resistant Staphylococcus aureus from raw milk samples collected from the local vendors in the region of Tirupathi, India

    Directory of Open Access Journals (Sweden)

    Sudhanthirakodi Sudhanthiramani

    2015-04-01

    Full Text Available Aim: The study was carried out with the aim to identify the suitability of the milk for consumer use with special reference to Staphylococcus aureus from milk samples collected from various local vendors and determine the antibiotic susceptibility pattern of those positive isolates. Materials and Methods: A total of 110 milk samples were collected from the local milk vendors in and around Tirupathi region of India. All the samples were enriched with buffered peptone water in 9:1 ratio and the then inoculated on baird parker agar medium with added 2% egg yolk tellurite emulsion as selective medium for S.aureus and confirmed with mannitol salt agar, Gram’s staining and biochemical tests. The typical cultural characters with coagulase-positive samples were taken as positive samples the positive samples were tested for antibiotic susceptibility with 10 different antibiotics by employing disc diffusion method. Results: Prevalence of coagulase-positive S. aureus was 39.09% (43/110 from the milk samples. The antibiotic susceptibility test of positive isolates showed high resistant toward penicillin G 37/43 (86.04% and ampicillin 32/43 (74.42%, and also showed resistant to methicillin 6/43 (13.95%, cephalothin 6/43 (13.95%, tetracycline 6/43 (13.95%, ciprofloxacin 4/43 (9.30%, enrofloxacin 3/43 (6.97%, cefoxitin 2/43 (4.65%, gentamicin 2/43 (4.65%, and co-trimoxazole 2/43 (4.65%. Many individual isolates showed resistant against two or more antibiotics in our study. Conclusion: The above study results show that the milk samples collected from local vendor having S. aureus, which can induce disease condition as well as antibiotic resistant to the humans particularly young children and old age peoples by means of consumption of raw milk and its products. This is the public health issue, which needs to be solved by educating the local vendors regarding health problems related to unhygienic milk supply and make the awareness among the consumers about this

  12. Isolation of Arcobacter butzleri in environmental and food samples collected in industrial and artisanal dairy plants

    Directory of Open Access Journals (Sweden)

    Federica Giacometti

    2013-10-01

    Full Text Available This study investigated the presence of Arcobacter species in two cheese factories; a total of 22 environmental samples and 10 food samples were collected from an artisanal and an industrial cheese factory; Arcobacter species were isolated after enrichment, and isolates were identified at species level by multiplex-polymerase chain reaction (PCR assay. In the artisanal cheese factory, Arcobacter spp. were isolated from several environmental samples, cow and water buffalo raw milk and ricotta cheese. In the industrial plant, Arcobacter spp. were isolated from surfaces not in contact with food and from a cleaned surface in contact with food; no Arcobacter spp. was isolated from food. All isolates were identified as A. butzleri. We report of the presence of A. butzleri in a ready-to-eat cheese produced for retail. In addition, the isolation of A. butzleri in food processing surfaces in the two cheese factories could be assessed as a source of potential contamination for cheeses

  13. Aspergillus species and other molds in respiratory samples from patients with cystic fibrosis:

    DEFF Research Database (Denmark)

    Mortensen, Klaus Leth; Jensen, Rasmus Hare; Johansen, Helle Krogh

    2011-01-01

    ,336 respiratory samples from 287 CF patients were collected during two 6-month periods in 2007 and 2009. Azole resistance was detected using an itraconazole screening agar (4 mg/liter) and the EUCAST method. cyp51A gene sequencing and microsatellite genotyping were performed for isolates from patients harboring...

  14. Testing a groundwater sampling tool: Are the samples representative?

    International Nuclear Information System (INIS)

    Kaback, D.S.; Bergren, C.L.; Carlson, C.A.; Carlson, C.L.

    1989-01-01

    A ground water sampling tool, the HydroPunch trademark, was tested at the Department of Energy's Savannah River Site in South Carolina to determine if representative ground water samples could be obtained without installing monitoring wells. Chemical analyses of ground water samples collected with the HydroPunch trademark from various depths within a borehole were compared with chemical analyses of ground water from nearby monitoring wells. The site selected for the test was in the vicinity of a large coal storage pile and a coal pile runoff basin that was constructed to collect the runoff from the coal storage pile. Existing monitoring wells in the area indicate the presence of a ground water contaminant plume that: (1) contains elevated concentrations of trace metals; (2) has an extremely low pH; and (3) contains elevated concentrations of major cations and anions. Ground water samples collected with the HydroPunch trademark provide in excellent estimate of ground water quality at discrete depths. Groundwater chemical data collected from various depths using the HydroPunch trademark can be averaged to simulate what a screen zone in a monitoring well would sample. The averaged depth-discrete data compared favorably with the data obtained from the nearby monitoring wells

  15. Analysis of water and soil from the wetlands of Upper Three Runs Creek. Volume 2A, Analytical data packages September--October 1991 sampling

    Energy Technology Data Exchange (ETDEWEB)

    Haselow, L.A.; Rogers, V.A. [Westinghouse Savannah River Co., Aiken, SC (United States); Riordan, C.J. [Metcalf and Eddy, Inc. (United States); Eidson, G.W.; Herring, M.K. [Normandeau Associates, Inc. (United States)

    1992-08-01

    Shallow water and soils along Upper Three Runs Creek (UTRC) and associated wetlands between SRS Road F and Cato Road were sampled for nonradioactive and radioactive constituents. The sampling program is associated with risk evaluations being performed for various regulatory documents in these areas of the Savannah River Site (SRS). WSRC selected fifty sampling sites bordering the Mixed Waste Management Facility (MWMF), F- and H-Area Seepage Basins (FHSB), and the Sanitary Landfill (SL). The analytical results from this study provided information on the water and soil quality in UTRC and its associated wetlands. The analytical results from this investigation indicated that the primary constituents and radiological indicators detected in the shallow water and soils were tritium, gross alpha, radium 226, total radium and strontium 90. This investigation involved the collection of shallow water samples during the Fall of 1991 and the Spring of 1992 at fifty (50) sampling locations. Sampling was performed during these periods to incorporate high and low water table periods. Samples were collected from three sections along UTRC denoted as Phase I (MWMF), Phase II (FHSB) and Phase III (SL). One vibracored soil sample was also collected in each phase during the Fall of 1991. This document is compiled solely of experimental data obtained from the sampling procedures.

  16. Analysis of water and soil from the wetlands of Upper Three Runs Creek. Volume 2B: Analytical data packages, January--February 1992 sampling

    Energy Technology Data Exchange (ETDEWEB)

    Haselow, L.A.; Rogers, V.A. [Westinghouse Savannah River Co., Aiken, SC (United States); Riordan, C.J. [Metcalf and Eddy (United States); Eidson, G.W.; Herring, M.K. [Normandeau Associates, Inc., Aiken, SC (United States)

    1992-08-01

    Shallow water and soils along Upper Three Runs Creek (UTRC) and associated wetlands between SRS Road F and Cato Road were sampled for nonradioactive and radioactive constituents. The sampling program is associated with risk evaluations being performed for various regulatory documents in these areas of the Savannah River Site (SRS). WSRC selected fifty sampling sites bordering the Mixed Waste Management Facility (MWMF), F- and H-Area Seepage Basins (FHSB), and the Sanitary Landfill (SL). The analytical results from this study provided information on the water and soil quality in UTRC and its associated wetlands. The analytical results from this investigation indicated that the primary constituents and radiological indicators detected in the shallow water and soils were tritium, gross alpha, radium 226, total radium and strontium 90. This investigation involved the collection of shallow water samples during the Fall of 1991 and the Spring of 1992 at fifty (50) sampling locations. Sampling was performed during these periods to incorporate high and low water table periods. Samples were collected from three sections along UTRC denoted as Phase I (MWMF), Phase II (FHSB) and Phase III (SL). One vibracored soil sample was also collected in each phase during the Fall of 1991. This document is compiled of experimental data obtained from the sampling procedures.

  17. Moessbauer studies on ancient Chinese pottery of Yangshao Culture Period

    International Nuclear Information System (INIS)

    Yu Zhengfang; Zheng Qi; Zheng Yufang; Zhongshan Univ., Guangzhou

    1988-01-01

    Eleven pieces of ancient Chinese pottery (4770 B.C. - 2960 B.C.) of Yangshao Culture Period collected from the Xi'an area have been studied by means of Moessbauer spectroscopy. The samples were refired up to 1100 0 C in steps of 100 0 C for 2 h in air. The highest temperature up to which the Moessbauer pattern remains basically unchanged can be identified with the original firing temperature. The result indicates that the firing temperatures for most of the sherds were between 900-1000 0 C. The function of the grit contained in the pottery has been discussed. The crimson and reddish painted materials on the surface of sherds have been studied, respectively. The first appearance of pottery can probably be traced back to an even earlier period. (orig.)

  18. Moessbauer studies on ancient Chinese pottery of Yangshao Culture Period

    Energy Technology Data Exchange (ETDEWEB)

    Zhengfang, Yu; Qi, Zheng; Yufang, Zheng

    1988-02-01

    Eleven pieces of ancient Chinese pottery (4770 B.C. - 2960 B.C.) of Yangshao Culture Period collected from the Xi'an area have been studied by means of Moessbauer spectroscopy. The samples were refired up to 1100/sup 0/C in steps of 100/sup 0/C for 2 h in air. The highest temperature up to which the Moessbauer pattern remains basically unchanged can be identified with the original firing temperature. The result indicates that the firing temperatures for most of the sherds were between 900-1000/sup 0/C. The function of the grit contained in the pottery has been discussed. The crimson and reddish painted materials on the surface of sherds have been studied, respectively. The first appearance of pottery can probably be traced back to an even earlier period.

  19. The collection and field chemical analysis of water samples

    International Nuclear Information System (INIS)

    Korte, N.E.; Ealey, D.T.; Hollenbach, M.H.

    1984-01-01

    A successful water sampling program requires a clear understanding of appropriate measurement and sampling procedures in order to obtain reliable field data and representative samples. It is imperative that the personnel involved have a thorough knowledge of the limitations of the techniques being used. Though this seems self-evident, many sampling and field-chemical-analysis programs are still not properly conducted. Recognizing these problems, the Department of Energy contracted with Bendix Field Engineering Corporation through the Technical Measurements Center to develop and select procedures for water sampling and field chemical analysis at waste sites. The fundamental causese of poor field programs are addressed in this paper, largely through discussion of specific field-measurement techniques and their limitations. Recommendations for improvement, including quality-assurance measures, are also presented

  20. Characteristics of HIV target CD4 T cells collected using different sampling methods from the genital tract of HIV seronegative women.

    Science.gov (United States)

    Iyer, Smita S; Sabula, Michael J; Mehta, C Christina; Haddad, Lisa B; Brown, Nakita L; Amara, Rama R; Ofotokun, Igho; Sheth, Anandi N

    2017-01-01

    Understanding the immune profile of CD4 T cells, the primary targets for HIV, in the female genital tract (FGT) is critical for evaluating and developing effective biomedical HIV prevention strategies in women. However, longitudinal investigation of HIV susceptibility markers expressed by FGT CD4 T cells has been hindered by low cellular yield and risk of sampling-associated trauma. We investigated three minimally invasive FGT sampling methods to characterize and compare CD4 T cell yield and phenotype with the goal of establishing feasible sampling strategies for immune profiling of mucosal CD4 T cells. FGT samples were collected bimonthly from 12 healthy HIV negative women of reproductive age in the following order: 1) Cervicovaginal lavage (CVL), 2) two sequential endocervical flocked swabs (FS), and 3) two sequential endocervical cytobrushes (CB1, CB2). Cells were isolated and phentoyped via flow cytometry. CD4 T cell recovery was highest from each individual CB compared to either CVL or FS (p sampling method, expressed CCR5 relative to peripheral blood (p samples. Using three different mucosal sampling methods collected longitudinally we demonstrate that CD4 T cells within the FGT express CCR5 and α4β7 and are highly activated, attributes which could act in concert to facilitate HIV acquisition. FS and CB sampling methods can allow for investigation of strategies to reduce HIV target cells in the FGT and could inform the design and interpretation microbicide and vaccine studies in women.

  1. Characterization of high level nuclear waste glass samples following extended melter idling

    Energy Technology Data Exchange (ETDEWEB)

    Fox, Kevin M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Peeler, David K. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Kruger, Albert A. [USDOE Office of River Protection, Richland, WA (United States)

    2015-06-16

    The Savannah River Site Defense Waste Processing Facility (DWPF) melter was recently idled with glass remaining in the melt pool and riser for approximately three months. This situation presented a unique opportunity to collect and analyze glass samples since outages of this duration are uncommon. The objective of this study was to obtain insight into the potential for crystal formation in the glass resulting from an extended idling period. The results will be used to support development of a crystal-tolerant approach for operation of the high-level waste melter at the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Two glass pour stream samples were collected from DWPF when the melter was restarted after idling for three months. The samples did not contain crystallization that was detectible by X-ray diffraction. Electron microscopy identified occasional spinel and noble metal crystals of no practical significance. Occasional platinum particles were observed by microscopy as an artifact of the sample collection method. Reduction/oxidation measurements showed that the pour stream glasses were fully oxidized, which was expected after the extended idling period. Chemical analysis of the pour stream glasses revealed slight differences in the concentrations of some oxides relative to analyses of the melter feed composition prior to the idling period. While these differences may be within the analytical error of the laboratories, the trends indicate that there may have been some amount of volatility associated with some of the glass components, and that there may have been interaction of the glass with the refractory components of the melter. These changes in composition, although small, can be attributed to the idling of the melter for an extended period. The changes in glass composition resulted in a 70-100 °C increase in the predicted spinel liquidus temperature (TL) for the pour stream glass samples relative to the analysis of the melter feed prior to

  2. 76 FR 73651 - Agency Information Collection Activities: Proposed Collection: Comment Request

    Science.gov (United States)

    2011-11-29

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Health Resources and Services Administration Agency Information Collection Activities: Proposed Collection: Comment Request Periodically, the Health Resources and... Resources and Services Administration (HRSA), Bureau of Clinician Recruitment and Service (BCRS) places...

  3. Effect of sample storage time on detection of hybridization signals in Checkerboard DNA-DNA hybridization.

    Science.gov (United States)

    do Nascimento, Cássio; Muller, Katia; Sato, Sandra; Albuquerque Junior, Rubens Ferreira

    2012-04-01

    Long-term sample storage can affect the intensity of the hybridization signals provided by molecular diagnostic methods that use chemiluminescent detection. The aim of this study was to evaluate the effect of different storage times on the hybridization signals of 13 bacterial species detected by the Checkerboard DNA-DNA hybridization method using whole-genomic DNA probes. Ninety-six subgingival biofilm samples were collected from 36 healthy subjects, and the intensity of hybridization signals was evaluated at 4 different time periods: (1) immediately after collecting (n = 24) and (2) after storage at -20 °C for 6 months (n = 24), (3) for 12 months (n = 24), and (4) for 24 months (n = 24). The intensity of hybridization signals obtained from groups 1 and 2 were significantly higher than in the other groups (p  0.05). The Checkerboard DNA-DNA hybridization method was suitable to detect hybridization signals from all groups evaluated, and the intensity of signals decreased significantly after long periods of sample storage.

  4. Sterile Reverse Osmosis Water Combined with Friction Are Optimal for Channel and Lever Cavity Sample Collection of Flexible Duodenoscopes

    Directory of Open Access Journals (Sweden)

    Michelle J. Alfa

    2017-11-01

    Full Text Available IntroductionSimulated-use buildup biofilm (BBF model was used to assess various extraction fluids and friction methods to determine the optimal sample collection method for polytetrafluorethylene channels. In addition, simulated-use testing was performed for the channel and lever cavity of duodenoscopes.Materials and methodsBBF was formed in polytetrafluorethylene channels using Enterococcus faecalis, Escherichia coli, and Pseudomonas aeruginosa. Sterile reverse osmosis (RO water, and phosphate-buffered saline with and without Tween80 as well as two neutralizing broths (Letheen and Dey–Engley were each assessed with and without friction. Neutralizer was added immediately after sample collection and samples concentrated using centrifugation. Simulated-use testing was done using TJF-Q180V and JF-140F Olympus duodenoscopes.ResultsDespite variability in the bacterial CFU in the BBF model, none of the extraction fluids tested were significantly better than RO. Borescope examination showed far less residual material when friction was part of the extraction protocol. The RO for flush-brush-flush (FBF extraction provided significantly better recovery of E. coli (p = 0.02 from duodenoscope lever cavities compared to the CDC flush method.Discussion and conclusionWe recommend RO with friction for FBF extraction of the channel and lever cavity of duodenoscopes. Neutralizer and sample concentration optimize recovery of viable bacteria on culture.

  5. National Coral Reef Monitoring Program: Water Chemistry of the Coral Reefs in American Samoa from Water Samples collected since 2015

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Water samples are collected and analyzed to assess spatial and temporal variation in the seawater carbonate systems of coral reef ecosystems in the Hawaiian and...

  6. Phenolic Profiling and Antioxidant Capacity of Eugenia uniflora L. (Pitanga) Samples Collected in Different Uruguayan Locations.

    Science.gov (United States)

    Migues, Ignacio; Baenas, Nieves; Gironés-Vilaplana, Amadeo; Cesio, María Verónica; Heinzen, Horacio; Moreno, Diego A

    2018-04-24

    The use of nutrient-rich foods to enhance the wellness, health and lifestyle habits of consumers is globally encouraged. Native fruits are of great interest as they are grown and consumed locally and take part of the ethnobotanic knowledge of the population. Pitanga is an example of a native fruit from Uruguay, consumed as a jelly or an alcoholic beverage. Pitanga has a red-violet pigmentation, which is a common trait for foods that are a good source of antioxidants. Hence, fruits from different Uruguayan regions were analyzed via miniaturized sample preparation method, HPLC-DAD-ESI/MS n and RP-HPLC-DAD techniques to identify and quantify phenolic compounds, respectively. The antioxidant capacity was evaluated via DPPH and ORAC (Oxygen Radical Absorbance Capacity) assays. A multivariate linear regression was applied to correlate the observed antioxidant capacity with the phenolic content. Furthermore, Principal Components Analysis was performed to highlight characteristics between the various samples studied. The main results indicated differences between northern and southern Uruguayan samples. Delphinidin-3-hexoside was present in southern samples (mean of 293.16 µmol/100 g dry weight (DW)) and absent in the sample collected in the north (sample 3). All the samples contain high levels of cyanidin-3-hexoside, but a noticeable difference was found between the northern sample (150.45 µmol/100 g DW) and the southern sample (1121.98 µmol/100 g DW). The antioxidant capacity (mean ORAC of 56370 µmol Trolox ® /100 g DW) were high in all the samples compared to the Food and Drug Administration (FDA) database of similar berry-fruits. The results of this study highlight the nutraceutical value of a native fruit that has not been exploited until now.

  7. Phenolic Profiling and Antioxidant Capacity of Eugenia uniflora L. (Pitanga Samples Collected in Different Uruguayan Locations

    Directory of Open Access Journals (Sweden)

    Ignacio Migues

    2018-04-01

    Full Text Available The use of nutrient-rich foods to enhance the wellness, health and lifestyle habits of consumers is globally encouraged. Native fruits are of great interest as they are grown and consumed locally and take part of the ethnobotanic knowledge of the population. Pitanga is an example of a native fruit from Uruguay, consumed as a jelly or an alcoholic beverage. Pitanga has a red-violet pigmentation, which is a common trait for foods that are a good source of antioxidants. Hence, fruits from different Uruguayan regions were analyzed via miniaturized sample preparation method, HPLC-DAD-ESI/MSn and RP-HPLC-DAD techniques to identify and quantify phenolic compounds, respectively. The antioxidant capacity was evaluated via DPPH and ORAC (Oxygen Radical Absorbance Capacity assays. A multivariate linear regression was applied to correlate the observed antioxidant capacity with the phenolic content. Furthermore, Principal Components Analysis was performed to highlight characteristics between the various samples studied. The main results indicated differences between northern and southern Uruguayan samples. Delphinidin-3-hexoside was present in southern samples (mean of 293.16 µmol/100 g dry weight (DW and absent in the sample collected in the north (sample 3. All the samples contain high levels of cyanidin-3-hexoside, but a noticeable difference was found between the northern sample (150.45 µmol/100 g DW and the southern sample (1121.98 µmol/100 g DW. The antioxidant capacity (mean ORAC of 56370 µmol Trolox®/100 g DW were high in all the samples compared to the Food and Drug Administration (FDA database of similar berry-fruits. The results of this study highlight the nutraceutical value of a native fruit that has not been exploited until now.

  8. Conducting Internet Research With the Transgender Population: Reaching Broad Samples and Collecting Valid Data.

    Science.gov (United States)

    Miner, Michael H; Bockting, Walter O; Romine, Rebecca Swinburne; Raman, Sivakumaran

    2012-05-01

    Health research on transgender people has been hampered by the challenges inherent in studying a hard-to-reach, relatively small, and geographically dispersed population. The Internet has the potential to facilitate access to transgender samples large enough to permit examination of the diversity and syndemic health disparities found among this population. In this article, we describe the experiences of a team of investigators using the Internet to study HIV risk behaviors of transgender people in the United States. We developed an online instrument, recruited participants exclusively via websites frequented by members of the target population, and collected data using online quantitative survey and qualitative synchronous and asynchronous interview methods. Our experiences indicate that the Internet environment presents the investigator with some unique challenges and that commonly expressed criticisms about Internet research (e.g., lack of generalizable samples, invalid study participants, and multiple participation by the same subject) can be overcome with careful method design, usability testing, and pilot testing. The importance of both usability and pilot testing are described with respect to participant engagement and retention and the quality of data obtained online.

  9. Report of the First Community Consultation on the Responsible Collection and Use of Samples for Genetic Research, September 25-26, 2000

    Energy Technology Data Exchange (ETDEWEB)

    Greenberg, Judith H.

    2002-05-22

    The First Community Consultation on the Responsible Collection and Use of Samples for Genetic Research was held in Bethesda, Maryland, on September 25-26, 2000. The consultation was convened by the National Institute of General Medical Sciences (NIGMS) of the National Institutes of Health (NIH). Approximately 120 individuals participated in the consultation, half from a broad range of communities and populations, and half from government. The participants shared their views and concerns about population- and community-based genetic research, expanding the focus of the meeting from the collection and use of blood or other tissue samples for genetic research to broader issues and concerns about the conduct of genetic research in general with populations and communities.

  10. Changes in background aerosol composition in Finland during polluted and clean periods studied by TEM/EDX individual particle analysis

    OpenAIRE

    Niemi , J. V.; Saarikoski , S.; Tervahattu , H.; Mäkelä , T.; Hillamo , R.; Vehkamäki , H.; Sogacheva , L.; Kulmala , M.

    2006-01-01

    Aerosol samples were collected at a rural background site in southern Finland in May 2004 during pollution episode (PM1~16 µg m−3, backward air mass trajectories from south-east), intermediate period (PM1~5 µg m−3, backtrajectories from north-east) and clean period (PM1~2 µg m−3, backtrajectories from north-west/north). The elemental composition, morphology and mixing state of individual aerosol particles in three size fractions were st...

  11. Sample handling for mass spectrometric proteomic investigations of human urine.

    Science.gov (United States)

    Petri, Anette Lykke; Høgdall, Claus; Christensen, Ib Jarle; Simonsen, Anja Hviid; T'jampens, Davy; Hellmann, Marja-Leena; Kjaer, Susanne Krüger; Fung, Eric T; Høgdall, Estrid

    2008-09-01

    Because of its non-invasive sample collection method, human urine is an attractive biological material both for discovering biomarkers and for use in future screening trials for different diseases. Before urine can be used for these applications, standardized protocols for sample handling that optimize protein stability are required. In this explorative study, we examine the influence of different urine collection methods, storage temperatures, storage times, and repetitive freeze-thaw procedures on the protein profiles obtained by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Prospectively collected urine samples from 11 women were collected as either morning or midday specimens. The effects of storage temperature, time to freezing, and freeze-thaw cycles were assessed by calculating the number, intensity, and reproducibility of peaks visualized by SELDI-TOF-MS. On the CM10 array, 122 peaks were detected and 28 peaks were found to be significantly different between urine types, storage temperature and time to freezing. On the IMAC-Cu array, 65 peaks were detected and 1 peak was found to be significantly different according to time to freezing. No significant differences were demonstrated for freeze-thaw cycles. Optimal handling and storage conditions are necessary in clinical urine proteomic investigations. Collection of urine with a single and consistently performed protocol is needed to reduce analytical bias. Collecting only one urine type, which is stored for a limited period at 4°C until freezing at -80°C prior to analysis will provide the most stable profiles. Copyright © 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Assessing representativeness of sampling methods for reaching men who have sex with men: a direct comparison of results obtained from convenience and probability samples.

    Science.gov (United States)

    Schwarcz, Sandra; Spindler, Hilary; Scheer, Susan; Valleroy, Linda; Lansky, Amy

    2007-07-01

    Convenience samples are used to determine HIV-related behaviors among men who have sex with men (MSM) without measuring the extent to which the results are representative of the broader MSM population. We compared results from a cross-sectional survey of MSM recruited from gay bars between June and October 2001 to a random digit dial telephone survey conducted between June 2002 and January 2003. The men in the probability sample were older, better educated, and had higher incomes than men in the convenience sample, the convenience sample enrolled more employed men and men of color. Substance use around the time of sex was higher in the convenience sample but other sexual behaviors were similar. HIV testing was common among men in both samples. Periodic validation, through comparison of data collected by different sampling methods, may be useful when relying on survey data for program and policy development.

  13. Autonomous water sampling for long-term monitoring of trace metals in remote environments.

    Science.gov (United States)

    Kim, Hyojin; Bishop, James K B; Wood, Todd J; Fung, Inez Y

    2012-10-16

    A remotely controlled autonomous method for long-term high-frequency sampling of environmental waters in remote locations is described. The method which preserves sample integrity of dissolved trace metals and major ions for month-long periods employs a gravitational filtration system (GFS) that separates dissolved and particulate phases as samples are collected. The key elements of GFS are (1) a modified "air-outlet" filter holder to maximize filtration rate and thus minimize filtration artifacts; and (2) the direct delivery of filtrate to dedicated bottle sets for specific analytes. Depth and screen filter types were evaluated with depth filters showing best performance. GFS performance is validated using ground, stream, and estuary waters. Over 30 days of storage, samples with GFS treatment had average recoveries of 95 ± 19% and 105 ± 7% of Fe and Mn, respectively; without GFS treatment, average recoveries were only 16% and 18%. Dissolved major cations K, Mg, and Na were stable independent of collection methodology, whereas Ca in some groundwater samples decreased up to 42% without GFS due to CaCO(3) precipitation. In-field performance of GFS equipped autosamplers is demonstrated using ground and streamwater samples collected at the Angelo Coast Range Reserve, California from October 3 to November 4 2011.

  14. Surface Sampling Collection and Culture Methods for Escherichia coli in Household Environments with High Fecal Contamination.

    Science.gov (United States)

    Exum, Natalie G; Kosek, Margaret N; Davis, Meghan F; Schwab, Kellogg J

    2017-08-22

    Empiric quantification of environmental fecal contamination is an important step toward understanding the impact that water, sanitation, and hygiene interventions have on reducing enteric infections. There is a need to standardize the methods used for surface sampling in field studies that examine fecal contamination in low-income settings. The dry cloth method presented in this manuscript improves upon the more commonly used swabbing technique that has been shown in the literature to have a low sampling efficiency. The recovery efficiency of a dry electrostatic cloth sampling method was evaluated using Escherichia coli and then applied to household surfaces in Iquitos, Peru, where there is high fecal contamination and enteric infection. Side-by-side measurements were taken from various floor locations within a household at the same time over a three-month period to compare for consistency of quantification of E. coli bacteria. The dry cloth sampling method in the laboratory setting showed 105% (95% Confidence Interval: 98%, 113%) E. coli recovery efficiency off of the cloths. The field application demonstrated strong agreement of side-by-side results (Pearson correlation coefficient for dirt surfaces was 0.83 ( p samples (Pearson (0.53, p method can be utilized in households with high bacterial loads using either continuous (quantitative) or categorical (semi-quantitative) data. The standardization of this low-cost, dry electrostatic cloth sampling method can be used to measure differences between households in intervention and non-intervention arms of randomized trials.

  15. Capture and exploration of sample quality data to inform and improve the management of a screening collection.

    Science.gov (United States)

    Charles, Isabel; Sinclair, Ian; Addison, Daniel H

    2014-04-01

    A new approach to the storage, processing, and interrogation of the quality data for screening samples has improved analytical throughput and confidence and enhanced the opportunities for learning from the accumulating records. The approach has entailed the design, development, and implementation of a database-oriented system, capturing information from the liquid chromatography-mass spectrometry capabilities used for assessing the integrity of samples in AstraZeneca's screening collection. A Web application has been developed to enable the visualization and interactive annotation of the analytical data, monitor the current sample queue, and report the throughput rate. Sample purity and identity are certified automatically on the chromatographic peaks of interest if predetermined thresholds are reached on key parameters. Using information extracted in parallel from the compound registration and container inventory databases, the chromatographic and spectroscopic profiles for each vessel are linked to the sample structures and storage histories. A search engine facilitates the direct comparison of results for multiple vessels of the same or similar compounds, for single vessels analyzed at different time points, or for vessels related by their origin or process flow. Access to this network of information has provided a deeper understanding of the multiple factors contributing to sample quality assurance.

  16. Determination of multi-element in marine sediment samples collected in Angola by the k0-NAA technique

    International Nuclear Information System (INIS)

    Teixeira, M.C.P.; Ho Manh Dung; Cao Dong Vu; Nguyen Thi Sy; Nguyen Thanh Binh; Vuong Huu Tan

    2006-01-01

    The marine sediment samples were designed to collect in Angola for marine environmental pollution study. The k 0 -standardization method of neutron activation analysis (k 0 -NAA) on Dalat research reactor has been developed to determine of multi-element in the Angola marine sediment samples. The samples were irradiated in cell 7-1 for short- and middle-lived nuclides and rotary specimen rack for long-lived nuclides. The irradiation facilities were characterized for neutron spectrum parameters and post-activated samples were measured on the calibrated gamma-ray spectrometers using HPGe detectors. The analytical results for 9 marine sediment samples with 27 elements: Al, As, Br, Ca, Ce,Cl, Co, Cs, Dy, Fe, Hf, I, K, Mg, Mn, Na, Rb, Sb, Sc, Se, Sm, Th, Ti, U, V and Zn in term of mean concentration, standard deviation and their content range are shown in the report. The analytical quality assurance was done by analysis of a Japan's certified reference material namely marine sediment NMIJ-CRM-7302a. These preliminary results revealed that the k 0 -NAA technique on the Dalat research reactor is a good analytical technique for determination of multi-element in the marine sediment samples. Some heavy metals and trace elements determined in this work possibly connected to the human activities at the sampling region. (author)

  17. Attitudes of Turkish Consumers toward Foreign Products in Political Crises Period

    Directory of Open Access Journals (Sweden)

    Durmus YÖRÜK

    2016-04-01

    Full Text Available This study aims to understand the attitudes of Turkish consumers toward foreign products in diplomatic crisis period. With this aim, at first, demographic characteristics of the consumers identified and then the relationship between independent variables which are consumer ethnocentrism and consumer animosity, and dependent variable which is willingness to buy foreign products is determined. In addition, the effect of product judgment as a moderator on the relationship between willingness to buy foreign products and consumer ethnocentrism and animosity is explored. Convenience sampling method was used in the study. Data was collected from students in Faculty of Economics and Administrative Sciences of Afyon Kocatepe University as based on voluntary basis. The data were collected between 20.10.2015 and 02.11.2015 and within this time period, it was reached to 418 students, totally. Thus, these 418 students in Faculty of Economics and Administrative Sciences became the sample of the research. Research findings show, different from the many researches in the literature, that consumer ethnocentrism, and consumer animosity do not negatively affect the willingness to buy foreign products even in a case when Turkey has a diplomatic problem with some countries. So the previous findings about the consumer ethnocentrism and the consumer animosity are challenged with the findings of this study within Turkey context. In this sense, this study contributes to the literature scholarly, by offering new findings about the existing constructs within different country context.

  18. Impact of collection conditions on the metabolite content of human urine samples as analyzed by liquid chromatography coupled to mass spectrometry and nuclear magnetic resonance spectroscopy

    OpenAIRE

    Roux, Aurélie; Thévenot, Etienne A.; Seguin, François; Olivier, Marie-Françoise; Junot, Christophe

    2014-01-01

    There is a lack of comprehensive studies documenting the impact of sample collection conditions on metabolic composition of human urine. To address this issue, two experiments were performed at a 3-month interval, in which midstream urine samples from healthy individuals were collected, pooled, divided into several aliquots and kept under specific conditions (room temperature, 4 °C, with or without preservative) up to 72 h before storage at −80 °C. Samples were analyzed by high-performance li...

  19. [Detection of Avian Influenza Virus in Environmental Samples Collected from Live Poultry Markets in China during 2009-2013].

    Science.gov (United States)

    Zhang, Ye; Li, Xiaodan; Zou, Shumei; Bo, Hong; Dong, Libo; Gao, Rongbao; Wang, Dayan; Shu, Yuelong

    2015-11-01

    Abstract: To investigate the distribution of avian influenza virus in environmental samples from live poultry markets (LPM) in China, samples were collected and tested by nucleic acid during 2009-2013 season. Each sample was tested by real-time RT PCR using flu A specific primers. If any real-time PCR was positive, the sample was inoculated into specific-pathogen-free (SPF) embryonated chicken eggs for viral isolation. The results indicated that the positive rate of nucleic acid in enviromental samples exhibited seasonality. The positive rate of nucleic acid was significantly higher in Winter and Spring. The positive rate of nucleic acid in LPM located in the south of China was higher than in northern China. Samples of Sewage for cleaning poultry and chopping board showed that higher positive rate of nucleic acid than other samples. The Subtype identification showed that H5 and H9 were main subtypes in the enviromental samples. Viral isolation indicated H5 subtypes was more than H9 subtypes between 2009 and 2013 while H9 subtypes increased in 2013. Our findings suggested the significance of public health based on LPM surveillance and provided the basis of prevention and early warning for avian flu infection human.

  20. Field Evaluation of Capillary Blood Samples as a Collection Specimen for the Rapid Diagnosis of Ebola Virus Infection During an Outbreak Emergency.

    Science.gov (United States)

    Strecker, Thomas; Palyi, Bernadett; Ellerbrok, Heinz; Jonckheere, Sylvie; de Clerck, Hilde; Bore, Joseph Akoi; Gabriel, Martin; Stoecker, Kilian; Eickmann, Markus; van Herp, Michel; Formenty, Pierre; Di Caro, Antonino; Becker, Stephan

    2015-09-01

    Reliable reverse transcription polymerase chain reaction (RT-PCR)-based diagnosis of Ebola virus infection currently requires a blood sample obtained by intravenous puncture. During the current Ebola outbreak in Guinea, we evaluated the usability of capillary blood samples collected from fingersticks of patients suspected of having Ebola virus disease (EVD) for field diagnostics during an outbreak emergency. A total of 120 venous and capillary blood samples were collected from 53 patients admitted to the Ebola Treatment Centre in Guéckédou, Guinea, between July and August 2014. All sample specimens were analyzed by RT-PCR using the RealStar Filovirus Screen RT-PCR Kit 1.0 from altona Diagnostics (Germany). We compared samples obtained by venipuncture and those obtained by capillary blood sampling absorbed onto swab devices. The resulting sensitivity and specificity of tests performed with capillary blood samples were 86.8% (95% confidence interval [CI], 71.9%-95.6%; 33/38 patients) and 100% (95% CI, 84.6%-100%; 22/22 patients), respectively. Our data suggest that capillary blood samples could serve as an alternative to venous blood samples for the diagnosis of EVD in resource-limited settings during a crisis. This can be of particular advantage in cases when venipuncture is difficult to perform-for example, with newborns and infants or when adult patients reject venipuncture for cultural or religious reasons. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America.

  1. Genetic Sample Inventory - NRDA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This database archives genetic tissue samples from marine mammals collected in the North-Central Gulf of Mexico from 2010-2015. The collection includes samples from...

  2. Choice of Sample Split in Out-of-Sample Forecast Evaluation

    DEFF Research Database (Denmark)

    Hansen, Peter Reinhard; Timmermann, Allan

    , while conversely the power of forecast evaluation tests is strongest with long out-of-sample periods. To deal with size distortions, we propose a test statistic that is robust to the effect of considering multiple sample split points. Empirical applications to predictabil- ity of stock returns......Out-of-sample tests of forecast performance depend on how a given data set is split into estimation and evaluation periods, yet no guidance exists on how to choose the split point. Empirical forecast evaluation results can therefore be difficult to interpret, particularly when several values...... and inflation demonstrate that out-of-sample forecast evaluation results can critically depend on how the sample split is determined....

  3. Slaughter value, meat quality, creatine kinase activity and cortisol levels in the blood serum of growing-finishing pigs slaughtered immediately after transport and after a rest period.

    Science.gov (United States)

    Smiecińska, K; Denaburski, J; Sobotka, W

    2011-01-01

    The experimental materials comprised 44 hybrid [female (Polish Large White x Polish Landrace) x male Duroc] growing-finishing pigs. The animals were randomly divided into two groups: 24 pigs were slaughtered immediately after transport and 20 pigs were slaughtered after a 24-hour rest period in the lairage. The meat content of pork carcasses, carcass dressing percentage, the proximate chemical composition, physicochemical and sensory properties of meat and shear force values were determined. Serum creatine kinase activity and cortisol levels were determined in blood samples collected before transport and during carcass bleeding. Pigs slaughtered immediately after transport, compared with those slaughtered after a 24-hour rest period, were characterized by a higher meat content of the carcass and a higher carcass dressing percentage. Pre-slaughter handling had no effect on pork quality. The incidence of normal-quality meat, partially PSE (pale, soft, exudative) meat and PSE meat was similar in both groups. Chemical analysis showed that the content of dry matter, total protein, fat and minerals in meat was comparable in both groups. As regards the functional properties of the pork, samples from the carcasses of pigs that had rested before slaughter had a higher contribution of the red color component. Meat from pigs slaughtered immediately after transport had more desirable sensory properties. Pre-slaughter resting had a significant effect on those analyzed physiological parameters which were found to be good indicators of pre-slaughter stress. Serum creatine kinase activity and cortisol levels were higher in blood samples collected after transport (during carcass bleeding) than in samples collected before transport, pointing to a strong stress response of animals to pre-slaughter treatment. The decrease in serum cortisol levels in blood samples collected during bleeding from the carcasses of pigs slaughtered after a 24-hour rest period, compared with samples

  4. 77 FR 74191 - Information Collection; Proposed Collection; Comment Request; General Services Administration...

    Science.gov (United States)

    2012-12-13

    ... target population to which generalizations will be made, the sampling frame, the sample design (including....regulations.gov . Submit comments via the Federal eRulemaking portal by searching for ``Information Collection... information collections that are designed to yield reliably actionable results, such as monitoring trends over...

  5. Survalytics: An Open-Source Cloud-Integrated Experience Sampling, Survey, and Analytics and Metadata Collection Module for Android Operating System Apps.

    Science.gov (United States)

    O'Reilly-Shah, Vikas; Mackey, Sean

    2016-06-03

    We describe here Survalytics, a software module designed to address two broad areas of need. The first area is in the domain of surveys and app analytics: developers of mobile apps in both academic and commercial environments require information about their users, as well as how the apps are being used, to understand who their users are and how to optimally approach app development. The second area of need is in the field of ecological momentary assessment, also referred to as experience sampling: researchers in a wide variety of fields, spanning from the social sciences to psychology to clinical medicine, would like to be able to capture daily or even more frequent data from research subjects while in their natural environment. Survalytics is an open-source solution for the collection of survey responses as well as arbitrary analytic metadata from users of Android operating system apps. Surveys may be administered in any combination of one-time questions and ongoing questions. The module may be deployed as a stand-alone app for experience sampling purposes or as an add-on to existing apps. The module takes advantage of free-tier NoSQL cloud database management offered by the Amazon Web Services DynamoDB platform to package a secure, flexible, extensible data collection module. DynamoDB is capable of Health Insurance Portability and Accountability Act compliant storage of personal health information. The provided example app may be used without modification for a basic experience sampling project, and we provide example questions for daily collection of blood glucose data from study subjects. The module will help researchers in a wide variety of fields rapidly develop tailor-made Android apps for a variety of data collection purposes.

  6. Survalytics: An Open-Source Cloud-Integrated Experience Sampling, Survey, and Analytics and Metadata Collection Module for Android Operating System Apps

    Science.gov (United States)

    Mackey, Sean

    2016-01-01

    Background We describe here Survalytics, a software module designed to address two broad areas of need. The first area is in the domain of surveys and app analytics: developers of mobile apps in both academic and commercial environments require information about their users, as well as how the apps are being used, to understand who their users are and how to optimally approach app development. The second area of need is in the field of ecological momentary assessment, also referred to as experience sampling: researchers in a wide variety of fields, spanning from the social sciences to psychology to clinical medicine, would like to be able to capture daily or even more frequent data from research subjects while in their natural environment. Objective Survalytics is an open-source solution for the collection of survey responses as well as arbitrary analytic metadata from users of Android operating system apps. Methods Surveys may be administered in any combination of one-time questions and ongoing questions. The module may be deployed as a stand-alone app for experience sampling purposes or as an add-on to existing apps. The module takes advantage of free-tier NoSQL cloud database management offered by the Amazon Web Services DynamoDB platform to package a secure, flexible, extensible data collection module. DynamoDB is capable of Health Insurance Portability and Accountability Act compliant storage of personal health information. Results The provided example app may be used without modification for a basic experience sampling project, and we provide example questions for daily collection of blood glucose data from study subjects. Conclusions The module will help researchers in a wide variety of fields rapidly develop tailor-made Android apps for a variety of data collection purposes. PMID:27261155

  7. Analysis and radiological assessment of survey results and samples from the beaches around Sellafield

    International Nuclear Information System (INIS)

    Webb, G.A.M.; Fry, F.A.

    1983-12-01

    After radioactive sea debris had been found on beaches near the BNFL, Sellafield, plant, NRPB was asked by the Department of the Environment to analyse some of the samples collected and to assess the radiological hazard to members of the public. A report is presented containing an analysis of survey reports for the period 19 November - 4 December 1983 and preliminary results of the analysis of all samples received, together with the Board's recommendations. (author)

  8. Sample handling and contamination encountered when coupling offline normal phase high performance liquid chromatography fraction collection of petroleum samples to Fourier transform ion cyclotron resonance mass spectrometry.

    Science.gov (United States)

    Oro, Nicole E; Whittal, Randy M; Lucy, Charles A

    2012-09-05

    Normal phase high performance liquid chromatography (HPLC) is used to separate a gas oil petroleum sample, and the fractions are collected offline and analyzed on a high resolution Fourier Transform Ion Cyclotron Resonance Mass Spectrometer (FT-ICR MS). The separation prior to MS analysis dilutes the sample significantly; therefore the fractions need to be prepared properly to achieve the best signal possible. The methods used to prepare the HPLC fractions for MS analysis are described, with emphasis placed on increasing the concentration of analyte species. The dilution effect also means that contamination in the MS spectra needs to be minimized. The contamination from molecular sieves, plastics, soap, etc. and interferences encountered during the offline fraction collection process are described and eliminated. A previously unreported MS contamination of iron formate clusters with a 0.8 mass defect in positive mode electrospray is also described. This interference resulted from the stainless steel tubing in the HPLC system. Contamination resulting from what has tentatively been assigned as palmitoylglycerol and stearoylglycerol was also observed; these compounds have not previously been reported as contaminant peaks. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Tracing decadal environmental change in ombrotrophic bogs using diatoms from herbarium collections and transfer functions.

    Science.gov (United States)

    Poulíčková, Aloisie; Hájková, Petra; Kintrová, Kateřina; Bat'ková, Romana; Czudková, Markéta; Hájek, Michal

    2013-08-01

    Central European mountain bogs, among the most valuable and threatened of habitats, were exposed to intensive human impact during the 20th century. We reconstructed the subrecent water chemistry and water-table depths using diatom based transfer functions calibrated from modern sampling. Herbarium Sphagnum specimens collected during the period 1918-1998 were used as a source of historic diatom samples. We classified samples into hummocks and hollows according to the identity of dominant Sphagnum species, to reduce bias caused by uneven sampling of particular microhabitats. Our results provide clear evidence for bog pollution by grazing during the period 1918-1947 and by undocumented aerial liming in the early 90-ies. We advocate use of herbarized epibryon as a source of information on subrecent conditions in recently polluted mires. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Random-effects linear modeling and sample size tables for two special crossover designs of average bioequivalence studies: the four-period, two-sequence, two-formulation and six-period, three-sequence, three-formulation designs.

    Science.gov (United States)

    Diaz, Francisco J; Berg, Michel J; Krebill, Ron; Welty, Timothy; Gidal, Barry E; Alloway, Rita; Privitera, Michael

    2013-12-01

    Due to concern and debate in the epilepsy medical community and to the current interest of the US Food and Drug Administration (FDA) in revising approaches to the approval of generic drugs, the FDA is currently supporting ongoing bioequivalence studies of antiepileptic drugs, the EQUIGEN studies. During the design of these crossover studies, the researchers could not find commercial or non-commercial statistical software that quickly allowed computation of sample sizes for their designs, particularly software implementing the FDA requirement of using random-effects linear models for the analyses of bioequivalence studies. This article presents tables for sample-size evaluations of average bioequivalence studies based on the two crossover designs used in the EQUIGEN studies: the four-period, two-sequence, two-formulation design, and the six-period, three-sequence, three-formulation design. Sample-size computations assume that random-effects linear models are used in bioequivalence analyses with crossover designs. Random-effects linear models have been traditionally viewed by many pharmacologists and clinical researchers as just mathematical devices to analyze repeated-measures data. In contrast, a modern view of these models attributes an important mathematical role in theoretical formulations in personalized medicine to them, because these models not only have parameters that represent average patients, but also have parameters that represent individual patients. Moreover, the notation and language of random-effects linear models have evolved over the years. Thus, another goal of this article is to provide a presentation of the statistical modeling of data from bioequivalence studies that highlights the modern view of these models, with special emphasis on power analyses and sample-size computations.

  11. Measurement of large asymptotic reactor periods from about 103 to 4.104 sec) to determine reactivity effects of small samples

    International Nuclear Information System (INIS)

    Grinevich, F.A.; Evchuk, A.I.; Klimentov, V.B.; Tyzh, A.V.; Churkin, Yu.I.; Yaroshevich, O.I.

    1977-01-01

    All investigation programs on fast reactor physics include measurements of low reactivity values (1-0.01)x10 -5 ΔK/K. An application of the pile oscillator technique for the purpose requires a special critical assembly for an installation of the oscillator. Thus it is of interest to develop relatively simple methods. In particular, one of such methods is the asymptotic period method which is widely used for low reactivity measurements. The description of the method and equipment developed for low reactivity measurements according to the measurements of the steady-state reactor period is presented. The equipment has been tested on the BTS-2 fast-thermal critical assembly. Measurement results on the reactivity effects of small samples in the fast zone centre are given. It is shown that the application of the method of measuring long steady-state periods and developed and tested equipment enables the reactivity of (1+-0.02)x10 -5 ΔK/K to be determined at the critical assembly power of 5 to 10 Wt. The disadvantage of the method presented is the time lost on reaching the steady-state period which results in greater sensitivity of the method to reactivity drifts

  12. Surface water/groundwater relationship in Chaj Doab. Final report for the period November 1985 - December 1989

    International Nuclear Information System (INIS)

    Hussain, S.D.

    1989-01-01

    In order to understand the relationship between surface water and groundwater in Chaj Doab area, isotopic and chemical studies were undertaken. Seven sets of water samples from hand pumps, tube wells, rivers and canals were collected during the period November 1985 to October 1988 and all the samples were analysed for environmental isotopes such as 2 H, 3 H, 18 O and the dissolved chemical constituents like Na + , K + , Ca ++ , Mg ++ , Cl - , NO 3 - , SO 4 -- and TIC. Some of the water samples having very low tritium concentrations were analysed for 14 C content. Analysis for 13 C values for two sets of samples was also carried out. 8 refs, 13 figs, 6 tabs

  13. Evaluation of a New Technique for iFOBT Utilising a New Sample Collection Device with Increased Buffer Stability.

    Science.gov (United States)

    Bruns-Toepler, Markus; Hardt, Philip

    2017-07-01

    The aims of the present study were: (i) Evaluate specificity and sensitivity of Hb Smart enzyme-linked immunosorbent assay (ELISA) (ScheBo Biotech) compared to colonoscopy results and (ii) assess stability of a new sample collection device containing a newly formulated buffer to extract haemoglobin using buffer and stool samples spiked with defined concentrations of haemoglobin. Stool samples were quantified with the ELISA method. The stability of haemoglobin in the extraction buffer and in native stool samples, respectively, was determined daily by ELISA during storage for 5 days at 4°C and at room temperature after addition of haemoglobin. Haemoglobin ELISA had a sensitivity of 78.4% for detection of CRC with a specificity of 98%. Haemoglobin extracted in corresponding extraction buffer demonstrated stability throughout storage for 5 days at 4°C and at room temperature. Hb Smart represents a very promising tool for large-scale screening of CRC with regard to sample handling, stability and analysis of haemoglobin in faeces. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  14. Comparison of PIXE and XRF analysis of airborne particulate matter samples collected on Teflon and quartz fibre filters

    Science.gov (United States)

    Chiari, M.; Yubero, E.; Calzolai, G.; Lucarelli, F.; Crespo, J.; Galindo, N.; Nicolás, J. F.; Giannoni, M.; Nava, S.

    2018-02-01

    Within the framework of research projects focusing on the sampling and analysis of airborne particulate matter, Particle Induced X-ray Emission (PIXE) and Energy Dispersive X-ray Fluorescence (ED-XRF) techniques are routinely used in many laboratories throughout the world to determine the elemental concentration of the particulate matter samples. In this work an inter-laboratory comparison of the results obtained from analysing several samples (collected on both Teflon and quartz fibre filters) using both techniques is presented. The samples were analysed by PIXE (in Florence, at the 3 MV Tandetron accelerator of INFN-LABEC laboratory) and by XRF (in Elche, using the ARL Quant'X EDXRF spectrometer with specific conditions optimized for specific groups of elements). The results from the two sets of measurements are in good agreement for all the analysed samples, thus validating the use of the ARL Quant'X EDXRF spectrometer and the selected measurement protocol for the analysis of aerosol samples. Moreover, thanks to the comparison of PIXE and XRF results on Teflon and quartz fibre filters, possible self-absorption effects due to the penetration of the aerosol particles inside the quartz fibre-filters were quantified.

  15. GASOLINE VEHICLE EXHAUST PARTICLE SAMPLING STUDY

    Energy Technology Data Exchange (ETDEWEB)

    Kittelson, D; Watts, W; Johnson, J; Zarling, D Schauer,J Kasper, K; Baltensperger, U; Burtscher, H

    2003-08-24

    The University of Minnesota collaborated with the Paul Scherrer Institute, the University of Wisconsin (UWI) and Ricardo, Inc to physically and chemically characterize the exhaust plume from recruited gasoline spark ignition (SI) vehicles. The project objectives were: (1) Measure representative particle size distributions from a set of on-road SI vehicles and compare these data to similar data collected on a small subset of light-duty gasoline vehicles tested on a chassis dynamometer with a dilution tunnel using the Unified Drive Cycle, at both room temperature (cold start) and 0 C (cold-cold start). (2) Compare data collected from SI vehicles to similar data collected from Diesel engines during the Coordinating Research Council E-43 project. (3) Characterize on-road aerosol during mixed midweek traffic and Sunday midday periods and determine fleet-specific emission rates. (4) Characterize bulk- and size-segregated chemical composition of the particulate matter (PM) emitted in the exhaust from the gasoline vehicles. Particle number concentrations and size distributions are strongly influenced by dilution and sampling conditions. Laboratory methods were evaluated to dilute SI exhaust in a way that would produce size distributions that were similar to those measured during laboratory experiments. Size fractionated samples were collected for chemical analysis using a nano-microorifice uniform deposit impactor (nano-MOUDI). In addition, bulk samples were collected and analyzed. A mixture of low, mid and high mileage vehicles were recruited for testing during the study. Under steady highway cruise conditions a significant particle signature above background was not measured, but during hard accelerations number size distributions for the test fleet were similar to modern heavy-duty Diesel vehicles. Number emissions were much higher at high speed and during cold-cold starts. Fuel specific number emissions range from 1012 to 3 x 1016 particles/kg fuel. A simple

  16. Tank vapor characterization project - headspace vapor characterization of Hanford Waste Tank 241-C-107: Second comparison study results from samples collected on 3/26/96

    International Nuclear Information System (INIS)

    Evans, J.C.; Pool, K.H.; Thomas, B.L.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of waste storage tank 241-C-107 (Tank C-107) at the Hanford Site in Washington State. The results described in this report is the second in a series comparing vapor sampling of the tank headspace using the Vapor Sampling System (VSS) and In Situ Vapor Sampling (ISVS) system without high efficiency particulate air (HEPA) prefiltration. The results include air concentrations of water (H 2 O) and ammonia (NH 3 ), permanent gases, total non-methane organic compounds (TO-12), and individual organic analytes collected in SUMMA trademark canisters and on triple sorbent traps (TSTs). Samples were collected by Westinghouse Hanford Company (WHC) and analyzed by Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, sample volume measurements provided by WHC

  17. Tank vapor characterization project. Headspace vapor characterization of Hanford waste tank 241-BY-108: Second comparison study results from samples collected on 3/28/96

    International Nuclear Information System (INIS)

    Thomas, B.L.; Pool, K.H.; Evans, J.C.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of waste storage tank 241-BY-108 (Tank BY-108) at the Hanford Site in Washington State. The results described in this report is the second in a series comparing vapor sampling of the tank headspace using the Vapor Sampling System (VSS) and In Situ Vapor Sampling (ISVS) system without high efficiency particulate air (HEPA) prefiltration. The results include air concentrations of water (H 2 O) and ammonia (NH 3 ), permanent gases, total non-methane organic compounds (TO-12), and individual organic analytes collected in SUMMA trademark canisters and on triple sorbent traps (TSTs). Samples were collected by Westinghouse Hanford Company (WHC) and analyzed by Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, sample volume measurements provided by WHC

  18. MAP3S Precipitation Chemistry Network: second periodic summary report, July 1977--June 1978

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-01

    The MAP3S Precipitation Chemistry Network consists of eight sites located in the northeastern United States. Precipitation event samples are collected by cooperating site operators, using specially developed sampling equipment. The concentration data collected over the period July 1, 1977 to July 1, 1978, are listed as a summary of the data reported monthly throughout the year. Samples were chemically analyzed at a central laboratory for 13 pollutant species - pH, conductivity, SO/sub 2/, SO/sub 4//sup =/, NH/sub 4//sup +/, NO/sub 2//sup -/, NO/sub 3//sup -/, Cl/sup -/, PO/sub 4//sup 3 -/, Na/sup +/, K/sup +/, Ca/sup + +/, and Mg/sup + +/ - using ion chromatography, automated wet chemistry, atomic absorption spectrophotometry, and electrode techniques. Second-year developments included: the installation of refrigeration equipment in all Battelle collectors; the initiation of an externally administered quality control program; and use of ion chromatography for cation as well as anion species. Supplementary research efforts included a special collector comparison study at the Pennsylvania State site and further analysis of sulfite versus sulfate deposition.

  19. Cerebral palsy in eastern Denmark: declining birth prevalence but increasing numbers of unilateral cerebral palsy in birth year period 1986-1998

    DEFF Research Database (Denmark)

    Ravn, Susanne Holst; Flachs, Esben Meulengracht; Uldall, Peter

    2010-01-01

    The Cerebral Palsy Registry in eastern Denmark has been collecting cases using a uniform data sampling procedure since birth year 1979. Children are included by two child neurologists and an obstetrician. Information on pregnancy, birth, neonatal period, impairments and demographic data...... are registered. The total cerebral palsy birth prevalence has been significantly decreasing since the birth period 1983-1986 with 3.0 per 1000 live births until the period 1995-1998 with 2.1 per 1000 live births. The overall decrease was seen in preterm infants (...

  20. Defining an optimum pumping-time requirement for sampling ground-water wells on the Hanford site

    International Nuclear Information System (INIS)

    Scharnhorst, N.L.

    1982-04-01

    The objective was to determine the optimum time period necessary to pump water from a well before a representative sample of the ground water can be obtained. It was assumed that a representative sample has been collected if the concentration of chemical parameters is the same in a number of samples taken consecutively, so that the concentration of parameters does not vary with time of collection. Ground-water samples used in this project were obtained by pumping selected wells on the Hanford Site. At each well, samples were taken at two minute intervals, and on each sample various chemical analyses were performed. Samples were checked for pH, sulfate, iron, specific conductivity, chloride, nitrate and alkalinity. The data showed that pH, alkalinity, sulfate and specific conductivity levels stabilized almost immediately after pumping of the well began. In many wells, the chloride and nitrate levels were unstable throughout the 38-minute sampling period. Iron levels, however, did not behave in either fashion. The concentration of iron in the samples was high when pumping began but dropped rapidly as pumping continued. The best explanation for this is that iron is flushed from the sides of the casing into the well when pumping begins. After several minutes of pumping, most of the dissolved iron is washed from the well casing and the iron concentration reaches a stable plateau representative of the iron concentration in the ground water.Since iron concentration takes longest to stabilize, the optimum pumping time for a well is based on the iron stabilization time for that well

  1. Conducting Internet Research With the Transgender Population: Reaching Broad Samples and Collecting Valid Data

    Science.gov (United States)

    Miner, Michael H.; Bockting, Walter O.; Romine, Rebecca Swinburne; Raman, Sivakumaran

    2013-01-01

    Health research on transgender people has been hampered by the challenges inherent in studying a hard-to-reach, relatively small, and geographically dispersed population. The Internet has the potential to facilitate access to transgender samples large enough to permit examination of the diversity and syndemic health disparities found among this population. In this article, we describe the experiences of a team of investigators using the Internet to study HIV risk behaviors of transgender people in the United States. We developed an online instrument, recruited participants exclusively via websites frequented by members of the target population, and collected data using online quantitative survey and qualitative synchronous and asynchronous interview methods. Our experiences indicate that the Internet environment presents the investigator with some unique challenges and that commonly expressed criticisms about Internet research (e.g., lack of generalizable samples, invalid study participants, and multiple participation by the same subject) can be overcome with careful method design, usability testing, and pilot testing. The importance of both usability and pilot testing are described with respect to participant engagement and retention and the quality of data obtained online. PMID:24031157

  2. Metabolic Disorders in Dairy Calves in Postpartum Period

    Directory of Open Access Journals (Sweden)

    A. Podhorský

    2007-01-01

    Full Text Available The aim of this study was, in terms of analysis of causes of disorders in calves on dairy farms, to evaluate occurrence of metabolic disorders in their postnatal period. In 23 agricultural farms (14 farms with the incidence of clinical forms of disease in calves during milk nutrition period - group D; 9 farms with no clinical disease - group H clinical examination was performed, blood samples were collected and data concerning the provision of permanent day and night care for calves (PDC during delivery and in early postpartum period were collected. The samples were taken from 3 - 5 calves in every farm (totally 97, H - 38, D - 59. Biochemical indicators that have some relations to the quality of colostral nutrition were determined (the concentrations of immunoglobulins - Ig, total protein - TP, albumin - A, globulins - G, vitamin E and A, the activity of gammaglutamyl transferase - GMT and to the microelement metabolism (the activities of glutathione peroxidase - GSH-Px for evaluation of selenium (Se status, the concentrations of copper (Cu and zinc (Zn. While evaluating the entire group of examined calves, we found a high occurrence of metabolic disorders in calves connected with colostral nutrition and also high occurrence of microelement deficiencies. The decrease in TP was diagnosed in 80%, the decrease in G in 78%, the decrease in concentration of Ig in 78% and 74% of calves had higher A/G ratio. Insufficient intake of colostrum showed also lower activities of GMT in 76% of calves. Hypovitaminosis E was diagnosed in 67% of calves and hypovitaminosis A in 19% of calves. Microelement deficiencies were found in 77% (Cu, 39% (Se, and 10% (Zn of calves. While comparing the results for calves in groups H and D, in the group of calves from farms with no clinical disease (H a significantly higher (p p p p < 0.01 A/G ratio, which proves a higher-quality colostral nutrition. The results thus prove that the incidence of metabolic disorders in dairy

  3. Recommended operating procedure number 56: Collection of gaseous grab samples from combustion sources for nitrous oxide measurement. Final report, Jan-Dec 91

    International Nuclear Information System (INIS)

    Ryan, J.V.; Karns, S.A.

    1992-07-01

    The document is a recommended operating procedure (ROP), prepared for use in research activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). The procedure applies to the collection of gaseous grab samples from fossil fuel combustion sources for subsequent analysis of nitrous oxide. The procedure details only the grab sampling methodology and associated equipment

  4. First detection and genotyping of Giardia intestinalis in stool samples collected from children in Ghazni Province, eastern Afghanistan and evaluation of the PCR assay in formalin-fixed specimens.

    Science.gov (United States)

    Lass, Anna; Karanis, Panagiotis; Korzeniewski, Krzysztof

    2017-08-01

    It is estimated that faecal-orally transmitted diseases are common in Afghanistan, as a consequence of poor hygienic standards of life and widespread contamination of water and food with both human and animal faeces. However, there is little information in the literature concerning infections caused by intestinal parasites in the Afghan population. In this study, we report the occurrence of Giardia intestinalis assemblages (A and B) in formalin-fixed stool samples collected from 245 Afghan schoolchildren living in Ghazni Province in eastern Afghanistan. Detection of the parasite's DNA and genotyping was performed using real-time PCR, specific to the β-giardin gene of G. intestinalis. Positive results were recorded in 52 (21.2%) samples. Genotyping was successful in 39 faecal samples and showed the predominance of assemblage B of G. intestinalis in this population (15 assemblage A and 24 assemblage B). Co-infection with both genotypes A and B was detected in four samples. Additionally, we evaluated the effect of 10% buffered formalin fixative on the detection of G. intestinalis DNA using real-time PCR and nested PCR characterised by different lengths of PCR products (74 and 479 bp, respectively). The human faeces containing the Giardia cysts were tested for 16 weeks. Amplification of G. intestinalis DNA with real-time PCR was possible up to 6 weeks of preservation of stool sample in formalin, compared to only 2 weeks with nested PCR. This suggests that real-time PCR is a more suitable tool in cases where stool samples have to be kept in formalin for longer periods of time.

  5. National Coral Reef Monitoring Program: Water Chemistry of the Coral Reefs in the Hawaiian Archipelago from Water Samples collected since 2013

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Water samples are collected and analyzed to assess spatial and temporal variation in the seawater carbonate systems of coral reef ecosystems in the Hawaiian and...

  6. National Coral Reef Monitoring Program: Water Chemistry of the Coral Reefs in the Mariana Archipelago from Water Samples collected in 2014

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Water samples are collected and analyzed to assess spatial and temporal variation in the seawater carbonate systems of coral reef ecosystems in the Hawaiian and...

  7. Bringing together raptor collections in Europe for contaminant research and monitoring in relation to chemicals regulations.

    Science.gov (United States)

    Movalli, Paola; Dekker, René; Koschorreck, Jan; Treu, Gabriele

    2017-11-01

    Raptors are good sentinels of environmental contamination and there is good capability for raptor biomonitoring in Europe. Raptor biomonitoring can benefit from natural history museums (NHMs), environmental specimen banks (ESBs) and other collections (e.g. specialist raptor specimen collections). Europe's NHMs, ESBs and other collections hold large numbers of raptor specimens and samples, covering long periods of time. These collections are potentially a valuable resource for contaminant studies over time and space. There are strong needs to monitor contaminants in the environment to support EU and national chemical management. However, data on raptor specimens in NHMs, ESBs and other collections are dispersed, few are digitised, and they are thus not easy to access. Specimen coverage is patchy in terms of species, space and time. Contaminant research with raptors would be facilitated by creating a framework to link relevant collections, digitising all collections, developing a searchable meta-database covering all existing collections, making them more visible and accessible for contaminant research. This would also help identify gaps in coverage and stimulate specimen collection to fill gaps in support of prioritised contaminant monitoring. Collections can further support raptor biomonitoring by making samples available for analysis on request.

  8. Chemometrics methods for the investigation of methylmercury and total mercury contamination in mollusks samples collected from coastal sites along the Chinese Bohai Sea.

    Science.gov (United States)

    Yawei, Wang; Lina, Liang; Jianbo, Shi; Guibin, Jiang

    2005-06-01

    The development and application of chemometrics methods, principal component analysis (PCA), cluster analysis and correlation analysis for the determination of methylmercury (MeHg) and total mecury (HgT) in gastropod and bivalve species collected from eight coastal sites along the Chinese Bohai Sea are described. HgT is directly determined by atomic fluorescence spectrometry (AFS), while MeHg is measured by a laboratory established high performance liquid chromatography-atomic fluorescence spectrometry system (HPLC-AFS). One-way ANOVA and cluster analysis indicated that the bioaccumulation of Rap to accumulate Hg was significantly (P<0.05) different from other mollusks. Correlation analysis shows that there is linear relationship between MeHg and HgT in mollusks samples collected from coastal sites along the Chinese Bohai Sea, while in mollusks samples collected from Hongqiao market in Beijing City, there is not any linear relationship.

  9. Sample Curation at a Lunar Outpost

    Science.gov (United States)

    Allen, Carlton C.; Lofgren, Gary E.; Treiman, A. H.; Lindstrom, Marilyn L.

    2007-01-01

    The six Apollo surface missions returned 2,196 individual rock and soil samples, with a total mass of 381.6 kg. Samples were collected based on visual examination by the astronauts and consultation with geologists in the science back room in Houston. The samples were photographed during collection, packaged in uniquely-identified containers, and transported to the Lunar Module. All samples collected on the Moon were returned to Earth. NASA's upcoming return to the Moon will be different. Astronauts will have extended stays at an out-post and will collect more samples than they will return. They will need curation and analysis facilities on the Moon in order to carefully select samples for return to Earth.

  10. Variation in levels of serum inhibin B, testosterone, estradiol, luteinizing hormone, follicle-stimulating hormone, and sex hormone-binding globulin in monthly samples from healthy men during a 17-month period

    DEFF Research Database (Denmark)

    Andersson, Anna-Maria; Carlsen, Elisabeth; Petersen, Jørgen Holm

    2003-01-01

    To obtain information on the scale of the intraindividual variation in testicular hormone, blood samples for inhibin B determination were collected monthly in 27 healthy male volunteers during a 17-month period. In addition, the traditional reproductive hormones FSH, LH, testosterone, estradiol....... A seasonal variation was observed in LH and testosterone levels, but not in the levels of the other hormones. The seasonal variation in testosterone levels could be explained by the variation in LH levels. The seasonal variation in LH levels seemed to be related to the mean air temperature during the month...... levels in men. The peak levels of both LH and testosterone were observed during June-July, with minimum levels present during winter-early spring. Air temperature, rather than light exposure, seems to be a possible climatic variable explaining the seasonal variation in LH levels....

  11. EXPLORING THE VARIABLE SKY WITH LINEAR. III. CLASSIFICATION OF PERIODIC LIGHT CURVES

    Energy Technology Data Exchange (ETDEWEB)

    Palaversa, Lovro; Eyer, Laurent; Rimoldini, Lorenzo [Observatoire Astronomique de l' Université de Genève, 51 chemin des Maillettes, CH-1290 Sauverny (Switzerland); Ivezić, Željko; Loebman, Sarah; Hunt-Walker, Nicholas; VanderPlas, Jacob; Westman, David; Becker, Andrew C. [Department of Astronomy, University of Washington, P.O. Box 351580, Seattle, WA 98195-1580 (United States); Ruždjak, Domagoj; Sudar, Davor; Božić, Hrvoje [Hvar Observatory, Faculty of Geodesy, Kačićeva 26, 10000 Zagreb (Croatia); Galin, Mario [Faculty of Geodesy, Kačićeva 26, 10000 Zagreb (Croatia); Kroflin, Andrea; Mesarić, Martina; Munk, Petra; Vrbanec, Dijana [Department of Physics, Faculty of Science, University of Zagreb, Bijenička cesta 32, 10000 Zagreb (Croatia); Sesar, Branimir [Division of Physics, Mathematics, and Astronomy, Caltech, Pasadena, CA 91125 (United States); Stuart, J. Scott [Lincoln Laboratory, Massachusetts Institute of Technology, 244 Wood Street, Lexington, MA 02420-9108 (United States); Srdoč, Gregor, E-mail: lovro.palaversa@unige.ch [Saršoni 90, 51216 Viškovo (Croatia); and others

    2013-10-01

    We describe the construction of a highly reliable sample of ∼7000 optically faint periodic variable stars with light curves obtained by the asteroid survey LINEAR across 10,000 deg{sup 2} of the northern sky. The majority of these variables have not been cataloged yet. The sample flux limit is several magnitudes fainter than most other wide-angle surveys; the photometric errors range from ∼0.03 mag at r = 15 to ∼0.20 mag at r = 18. Light curves include on average 250 data points, collected over about a decade. Using Sloan Digital Sky Survey (SDSS) based photometric recalibration of the LINEAR data for about 25 million objects, we selected ∼200,000 most probable candidate variables with r < 17 and visually confirmed and classified ∼7000 periodic variables using phased light curves. The reliability and uniformity of visual classification across eight human classifiers was calibrated and tested using a catalog of variable stars from the SDSS Stripe 82 region and verified using an unsupervised machine learning approach. The resulting sample of periodic LINEAR variables is dominated by 3900 RR Lyrae stars and 2700 eclipsing binary stars of all subtypes and includes small fractions of relatively rare populations such as asymptotic giant branch stars and SX Phoenicis stars. We discuss the distribution of these mostly uncataloged variables in various diagrams constructed with optical-to-infrared SDSS, Two Micron All Sky Survey, and Wide-field Infrared Survey Explorer photometry, and with LINEAR light-curve features. We find that the combination of light-curve features and colors enables classification schemes much more powerful than when colors or light curves are each used separately. An interesting side result is a robust and precise quantitative description of a strong correlation between the light-curve period and color/spectral type for close and contact eclipsing binary stars (β Lyrae and W UMa): as the color-based spectral type varies from K4 to F5, the

  12. Yield of acid curd cheese produced from cow's milk from different lactation periods.

    Science.gov (United States)

    Salamończyk, Ewa; Młynek, Krzysztof; Guliński, Piotr; Zawadzka, Wiesława

    2017-01-01

    Milk production intensification has led in many countries, including Poland, to increased milk yields per cow. A higher milk yield resulted in changes in cow productivity, including extended lactations. There is a paucity of information on the quality of milk harvested during the last months of lactations exceed- ing 10 months. Production capacity cheese (“cheese expenditure”) is an important parameter of providing   a recovery as much as the possible components of the milk processed are dry substances, which in turn af- fects the economics of production. The aim of the study was to determine the influence of the lactation period (from standard lactation; extended lactation phase) on the performance of the acid curd cheese. the relation- ship between total protein content and acidity of fresh milk collected in two separate periods of lactation on the yield of acid cheese was also evaluated. The study included 1384 samples of milk collected from Polish Holstein-Friesian cows, the Black-White variety. The basic chemical composition of fresh milk and acid-curd cheese produced in the laboratory were analyzed. The cheese milk yield was evaluated on the basis of the quantity of the re- sulting curd mass. According to our estimates, under laboratory conditions an average of 100 kg of milk per cow in population produced an estimated 20.1 kg of curd cheese. The basic chemical composition of raw milk, which was diverse in terms of the period of lactation, showed a higher dry matter, fat and protein content in milk acquired during the extension phase of lactation compared to the milk of standard lactation. It has been found that the lower titratable acidity of fresh milk appeared with a higher yield of cheese curd. This difference was between 1.76 kg (with milk from cows milked during the extended lactation phase) to 2.72 kg from 100 kg of cheese milk (milk with the standard lactation). Thus, the optimum level of titratable acidity of milk for cheese yield is 6.0–7.5

  13. GENETIC DIVERSITY OF VIR COLLECTIONS OF THE RAPHANUS SATIVUS L. (SMALL RADISH AND RADISH

    Directory of Open Access Journals (Sweden)

    A. B. Kurina

    2017-01-01

    Full Text Available The study on the diversity of root plants in the species of Raphanus sativus L., which are available in the collection of VIR, enables to comprehensively evaluate the collection of small radish and radish, making descriptions of new forms and cultivar-types, and revealing the biological features of the formation of photosynthetic apparatus, yielding abilities, resistance to biotic and abiotic stressors. This article is the first part of a series of articles devoted to the study of the gene pool of root plants of the species R. sativus L. from the VIR collection. The experimental part of the article includes the results of a study of previously unexplored accessions from the radish collection, the following articles will be devoted to the radish gene pool. As a result of the research conducted in 2016-2017. 110 samples of radish of different eco-geographical origin and representing variety of cultivar type were studied. The studied radish samples were combined into several groups according to the duration of the growing season (early ripening, mid-ripening and late ripening. A longer vegetation period in radish in winter-time-growing was observed in case of insufficient illumination, but some accesions of the red oval-rounded cultivar type (k-2133, k-2343, k-1742, k-2404 have not shown any change in vegetation period. There was a strong change in the shape of the root crop when growing in winter under insufficient illumination. Samples that are capable to form a consumed organ in such conditions without changing the shape of the root crop and vegetation period were k-2404, Netherlands, k-2133, Tanzania, k-2185, Poland, k-2343, Iceland, k-1666, Russia. Among the accessions of the red-oval-round cultivar type, varieties from the Netherlands, the Czech Republic and Poland emerged, formed a short-rooted, compact rosette with an elevated leaf arrangement in all growing conditions. The formation of high productivity in the open field types was revealed

  14. INAA of airborne particulate matter collected in Bangkok 2002-2004

    International Nuclear Information System (INIS)

    Chueinta, W.; Bunprapob, S.; Tedthong, S.

    2006-01-01

    This paper presents the summary report of the monitoring study on ambient air quality in Bangkok metropolis and its boundary covering the period from 2002 to 2004. The work performed included sampling of fine and coarse fractions of particulate matter at the sites representing urban and suburban areas; measurement of particle mass concentration and elemental concentration; and data interpretation. Instrumental neutron activation by use of research reactor facilities at Office of Atoms for Peace was carried out for multielemental analysis of all filter samples collected. Twenty elements were determined. The database of the three consecutive years are summarized and reviewed in this paper. (author)

  15. Waste classification sampling plan

    International Nuclear Information System (INIS)

    Landsman, S.D.

    1998-01-01

    The purpose of this sampling is to explain the method used to collect and analyze data necessary to verify and/or determine the radionuclide content of the B-Cell decontamination and decommissioning waste stream so that the correct waste classification for the waste stream can be made, and to collect samples for studies of decontamination methods that could be used to remove fixed contamination present on the waste. The scope of this plan is to establish the technical basis for collecting samples and compiling quantitative data on the radioactive constituents present in waste generated during deactivation activities in B-Cell. Sampling and radioisotopic analysis will be performed on the fixed layers of contamination present on structural material and internal surfaces of process piping and tanks. In addition, dose rate measurements on existing waste material will be performed to determine the fraction of dose rate attributable to both removable and fixed contamination. Samples will also be collected to support studies of decontamination methods that are effective in removing the fixed contamination present on the waste. Sampling performed under this plan will meet criteria established in BNF-2596, Data Quality Objectives for the B-Cell Waste Stream Classification Sampling, J. M. Barnett, May 1998

  16. [Methanotrophs and methylobacteria are found in woody plant tissues within a winter period].

    Science.gov (United States)

    Doronina, N V; Ivanova, E G; Suzina, N F; Trotsenko, Iu A

    2004-01-01

    Samples of tree seeds, buds, and needles collected within a winter period at ambient temperatures from -11 to -17 degrees C were analyzed for the presence of methylotrophic microflora. Thin sections of blue spruce needles were found to contain bacteria morphologically close to pink-pigmented methylobacteria. The methylobacteria that were isolated in pure cultures from samples of linden seeds and buds, pine and blue spruce needles, as well as of lilac, maple, and apple buds, were classified into the genera Methylobacterium and Paracoccus based on the data of morphological studies, enzyme assay, and DNA-DNA hybridization analysis. The methanotrophs that were isolated in pure cultures from samples of linden buds and blue spruce needles were identified into the genus Methylocystis based on the data of morphological studies, enzyme assay, DNA-DNA hybridization, and the phylogenetic analysis of the particulate methane monooxygenase gene pmoA sequences. The inference is made that aerobic methylotrophic bacteria are permanently associated with plants. At the beginning of the vegetative period in spring, the phyllosphere of coniferous and deciduous trees is colonized by the methylotrophic bacteria that have wintered inside plant tissues.

  17. Means and method of sampling flow related variables from a waterway in an accurate manner using a programmable calculator

    Science.gov (United States)

    Rand E. Eads; Mark R. Boolootian; Steven C. [Inventors] Hankin

    1987-01-01

    Abstract - A programmable calculator is connected to a pumping sampler by an interface circuit board. The calculator has a sediment sampling program stored therein and includes a timer to periodically wake up the calculator. Sediment collection is controlled by a Selection At List Time (SALT) scheme in which the probability of taking a sample is proportional to its...

  18. Efficiently sampling conformations and pathways using the concurrent adaptive sampling (CAS) algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Surl-Hee; Grate, Jay W.; Darve, Eric F.

    2017-08-21

    Molecular dynamics (MD) simulations are useful in obtaining thermodynamic and kinetic properties of bio-molecules but are limited by the timescale barrier, i.e., we may be unable to efficiently obtain properties because we need to run microseconds or longer simulations using femtoseconds time steps. While there are several existing methods to overcome this timescale barrier and efficiently sample thermodynamic and/or kinetic properties, problems remain in regard to being able to sample un- known systems, deal with high-dimensional space of collective variables, and focus the computational effort on slow timescales. Hence, a new sampling method, called the “Concurrent Adaptive Sampling (CAS) algorithm,” has been developed to tackle these three issues and efficiently obtain conformations and pathways. The method is not constrained to use only one or two collective variables, unlike most reaction coordinate-dependent methods. Instead, it can use a large number of collective vari- ables and uses macrostates (a partition of the collective variable space) to enhance the sampling. The exploration is done by running a large number of short simula- tions, and a clustering technique is used to accelerate the sampling. In this paper, we introduce the new methodology and show results from two-dimensional models and bio-molecules, such as penta-alanine and triazine polymer

  19. Effects of the number of people on efficient capture and sample collection: A lion case study

    Directory of Open Access Journals (Sweden)

    Sam M. Ferreira

    2013-05-01

    Full Text Available Certain carnivore research projects and approaches depend on successful capture of individuals of interest. The number of people present at a capture site may determine success of a capture. In this study 36 lion capture cases in the Kruger National Park were used to evaluate whether the number of people present at a capture site influenced lion response rates and whether the number of people at a sampling site influenced the time it took to process the collected samples. The analyses suggest that when nine or fewer people were present, lions appeared faster at a call-up locality compared with when there were more than nine people. The number of people, however, did not influence the time it took to process the lions. It is proposed that efficient lion capturing should spatially separate capture and processing sites and minimise the number of people at a capture site.

  20. Effects of the number of people on efficient capture and sample collection: a lion case study.

    Science.gov (United States)

    Ferreira, Sam M; Maruping, Nkabeng T; Schoultz, Darius; Smit, Travis R

    2013-05-24

    Certain carnivore research projects and approaches depend on successful capture of individuals of interest. The number of people present at a capture site may determine success of a capture. In this study 36 lion capture cases in the Kruger National Park were used to evaluate whether the number of people present at a capture site influenced lion response rates and whether the number of people at a sampling site influenced the time it took to process the collected samples. The analyses suggest that when nine or fewer people were present, lions appeared faster at a call-up locality compared with when there were more than nine people. The number of people, however, did not influence the time it took to process the lions. It is proposed that efficient lion capturing should spatially separate capture and processing sites and minimise the number of people at a capture site.

  1. Enhanced water collection through a periodic array of tiny holes in dropwise condensation

    Science.gov (United States)

    Song, Kyungjun; Kim, Gyeonghee; Oh, Sunjong; Lim, Hyuneui

    2018-02-01

    This paper introduces a simple method of water collection by increasing the coalescence effects in dropwise condensation with the use of microscale holes. The tiny holes modified the surface free energy states of the droplets on the plate, yielding a surface free energy barrier between the flat solid surface and the holes. The spatial difference in the surface free energy of the droplets enabled the droplets to move toward the adjacent droplets, thus increasing the possibility of coalescence. The water collection experiments were performed using a Peltier-based cooling system at 2 °C inside a chamber at 30 °C and 70% humidity. The results demonstrated that the perforated plates without any additional treatment provided the water collection rate of up to 22.64 L/m2 day, which shows an increase of 30% compared to that demonstrated by the bare plate. By comparing the experimental results for the surface of filmwise condensation, it was proved that the dominant water collecting improvement results from the increased coalescence effects. This simple technique can enhance the performance of systems exposed to water condensation, including water collection, heat-transfer, and dehumidifying systems.

  2. Tracing decadal environmental change in ombrotrophic bogs using diatoms from herbarium collections and transfer functions

    International Nuclear Information System (INIS)

    Poulíčková, Aloisie; Hájková, Petra; Kintrová, Kateřina; Bat'ková, Romana; Czudková, Markéta; Hájek, Michal

    2013-01-01

    Central European mountain bogs, among the most valuable and threatened of habitats, were exposed to intensive human impact during the 20th century. We reconstructed the subrecent water chemistry and water-table depths using diatom based transfer functions calibrated from modern sampling. Herbarium Sphagnum specimens collected during the period 1918–1998 were used as a source of historic diatom samples. We classified samples into hummocks and hollows according to the identity of dominant Sphagnum species, to reduce bias caused by uneven sampling of particular microhabitats. Our results provide clear evidence for bog pollution by grazing during the period 1918–1947 and by undocumented aerial liming in the early 90-ies. We advocate use of herbarized epibryon as a source of information on subrecent conditions in recently polluted mires. -- Highlights: •We reconstruct the subrecent ecological variables using transfer functions. •Calibration was based on long-term averages and modern diatom sampling. •Herbarized bryophytes were used as a source of historic diatom samples. •Bogs were influenced by grazing in the period 1918–1947. •We provide clear evidence of bog pollution by aerial liming in early 90-ies. -- We provide clear evidence that the recent pH/calcium gradient appeared ca 20 years ago owing to aerial liming of forests

  3. Sampling strategies to measure the prevalence of common recurrent infections in longitudinal studies

    Directory of Open Access Journals (Sweden)

    Luby Stephen P

    2010-08-01

    Full Text Available Abstract Background Measuring recurrent infections such as diarrhoea or respiratory infections in epidemiological studies is a methodological challenge. Problems in measuring the incidence of recurrent infections include the episode definition, recall error, and the logistics of close follow up. Longitudinal prevalence (LP, the proportion-of-time-ill estimated by repeated prevalence measurements, is an alternative measure to incidence of recurrent infections. In contrast to incidence which usually requires continuous sampling, LP can be measured at intervals. This study explored how many more participants are needed for infrequent sampling to achieve the same study power as frequent sampling. Methods We developed a set of four empirical simulation models representing low and high risk settings with short or long episode durations. The model was used to evaluate different sampling strategies with different assumptions on recall period and recall error. Results The model identified three major factors that influence sampling strategies: (1 the clustering of episodes in individuals; (2 the duration of episodes; (3 the positive correlation between an individual's disease incidence and episode duration. Intermittent sampling (e.g. 12 times per year often requires only a slightly larger sample size compared to continuous sampling, especially in cluster-randomized trials. The collection of period prevalence data can lead to highly biased effect estimates if the exposure variable is associated with episode duration. To maximize study power, recall periods of 3 to 7 days may be preferable over shorter periods, even if this leads to inaccuracy in the prevalence estimates. Conclusion Choosing the optimal approach to measure recurrent infections in epidemiological studies depends on the setting, the study objectives, study design and budget constraints. Sampling at intervals can contribute to making epidemiological studies and trials more efficient, valid

  4. Sampling pig farms at the abattoir in a cross-sectional study - Evaluation of a sampling method.

    Science.gov (United States)

    Birkegård, Anna Camilla; Halasa, Tariq; Toft, Nils

    2017-09-15

    A cross-sectional study design is relatively inexpensive, fast and easy to conduct when compared to other study designs. Careful planning is essential to obtaining a representative sample of the population, and the recommended approach is to use simple random sampling from an exhaustive list of units in the target population. This approach is rarely feasible in practice, and other sampling procedures must often be adopted. For example, when slaughter pigs are the target population, sampling the pigs on the slaughter line may be an alternative to on-site sampling at a list of farms. However, it is difficult to sample a large number of farms from an exact predefined list, due to the logistics and workflow of an abattoir. Therefore, it is necessary to have a systematic sampling procedure and to evaluate the obtained sample with respect to the study objective. We propose a method for 1) planning, 2) conducting, and 3) evaluating the representativeness and reproducibility of a cross-sectional study when simple random sampling is not possible. We used an example of a cross-sectional study with the aim of quantifying the association of antimicrobial resistance and antimicrobial consumption in Danish slaughter pigs. It was not possible to visit farms within the designated timeframe. Therefore, it was decided to use convenience sampling at the abattoir. Our approach was carried out in three steps: 1) planning: using data from meat inspection to plan at which abattoirs and how many farms to sample; 2) conducting: sampling was carried out at five abattoirs; 3) evaluation: representativeness was evaluated by comparing sampled and non-sampled farms, and the reproducibility of the study was assessed through simulated sampling based on meat inspection data from the period where the actual data collection was carried out. In the cross-sectional study samples were taken from 681 Danish pig farms, during five weeks from February to March 2015. The evaluation showed that the sampling

  5. Distribution Coeficients (Kd) Generated From A Core Sample Collected From The Saltstone Disposal Facility

    International Nuclear Information System (INIS)

    Almond, P.; Kaplan, D.

    2011-01-01

    Core samples originating from Vault 4, Cell E of the Saltstone Disposal Facility (SDF) were collected in September of 2008 (Hansen and Crawford 2009, Smith 2008) and sent to SRNL to measure chemical and physical properties of the material including visual uniformity, mineralogy, microstructure, density, porosity, distribution coefficients (K d ), and chemical composition. Some data from these experiments have been reported (Cozzi and Duncan 2010). In this study, leaching experiments were conducted with a single core sample under conditions that are representative of saltstone performance. In separate experiments, reducing and oxidizing environments were targeted to obtain solubility and Kd values from the measurable species identified in the solid and aqueous leachate. This study was designed to provide insight into how readily species immobilized in saltstone will leach from the saltstone under oxidizing conditions simulating the edge of a saltstone monolith and under reducing conditions, targeting conditions within the saltstone monolith. Core samples were taken from saltstone poured in December of 2007 giving a cure time of nine months in the cell and a total of thirty months before leaching experiments began in June 2010. The saltstone from Vault 4, Cell E is comprised of blast furnace slag, class F fly ash, portland cement, and Deliquification, Dissolution, and Adjustment (DDA) Batch 2 salt solution. The salt solution was previously analyzed from a sample of Tank 50 salt solution and characterized in the 4QCY07 Waste Acceptance Criteria (WAC) report (Zeigler and Bibler 2009). Subsequent to Tank 50 analysis, additional solution was added to the tank solution from the Effluent Treatment Project as well as from inleakage from Tank 50 pump bearings (Cozzi and Duncan 2010). Core samples were taken from three locations and at three depths at each location using a two-inch diameter concrete coring bit (1-1, 1-2, 1-3; 2-1, 2-2, 2-3; 3-1, 3-2, 3-3) (Hansen and Crawford

  6. DISTRIBUTION COEFICIENTS (KD) GENERATED FROM A CORE SAMPLE COLLECTED FROM THE SALTSTONE DISPOSAL FACILITY

    Energy Technology Data Exchange (ETDEWEB)

    Almond, P.; Kaplan, D.

    2011-04-25

    Core samples originating from Vault 4, Cell E of the Saltstone Disposal Facility (SDF) were collected in September of 2008 (Hansen and Crawford 2009, Smith 2008) and sent to SRNL to measure chemical and physical properties of the material including visual uniformity, mineralogy, microstructure, density, porosity, distribution coefficients (K{sub d}), and chemical composition. Some data from these experiments have been reported (Cozzi and Duncan 2010). In this study, leaching experiments were conducted with a single core sample under conditions that are representative of saltstone performance. In separate experiments, reducing and oxidizing environments were targeted to obtain solubility and Kd values from the measurable species identified in the solid and aqueous leachate. This study was designed to provide insight into how readily species immobilized in saltstone will leach from the saltstone under oxidizing conditions simulating the edge of a saltstone monolith and under reducing conditions, targeting conditions within the saltstone monolith. Core samples were taken from saltstone poured in December of 2007 giving a cure time of nine months in the cell and a total of thirty months before leaching experiments began in June 2010. The saltstone from Vault 4, Cell E is comprised of blast furnace slag, class F fly ash, portland cement, and Deliquification, Dissolution, and Adjustment (DDA) Batch 2 salt solution. The salt solution was previously analyzed from a sample of Tank 50 salt solution and characterized in the 4QCY07 Waste Acceptance Criteria (WAC) report (Zeigler and Bibler 2009). Subsequent to Tank 50 analysis, additional solution was added to the tank solution from the Effluent Treatment Project as well as from inleakage from Tank 50 pump bearings (Cozzi and Duncan 2010). Core samples were taken from three locations and at three depths at each location using a two-inch diameter concrete coring bit (1-1, 1-2, 1-3; 2-1, 2-2, 2-3; 3-1, 3-2, 3-3) (Hansen and

  7. Direct PCR amplification of DNA from human bloodstains, saliva, and touch samples collected with microFLOQ® swabs.

    Science.gov (United States)

    Ambers, Angie; Wiley, Rachel; Novroski, Nicole; Budowle, Bruce

    2018-01-01

    Previous studies have shown that nylon flocked swabs outperform traditional fiber swabs in DNA recovery due to their innovative design and lack of internal absorbent core to entrap cellular materials. The microFLOQ ® Direct swab, a miniaturized version of the 4N6 FLOQSwab ® , has a small swab head that is treated with a lysing agent which allows for direct amplification and DNA profiling from sample collection to final result in less than two hours. Additionally, the microFLOQ ® system subsamples only a minute portion of a stain and preserves the vast majority of the sample for subsequent testing or re-analysis, if desired. The efficacy of direct amplification of DNA from dilute bloodstains, saliva stains, and touch samples was evaluated using microFLOQ ® Direct swabs and the GlobalFiler™ Express system. Comparisons were made to traditional methods to assess the robustness of this alternate workflow. Controlled studies with 1:19 and 1:99 dilutions of bloodstains and saliva stains consistently yielded higher STR peak heights than standard methods with 1ng input DNA from the same samples. Touch samples from common items yielded single source and mixed profiles that were consistent with primary users of the objects. With this novel methodology/workflow, no sample loss occurs and therefore more template DNA is available during amplification. This approach may have important implications for analysis of low quantity and/or degraded samples that plague forensic casework. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  8. Identification of Viruses Present in Tissues Collected from Chickens with Hypoglycemia-Spiking Mortality Syndrome (H-SMS).

    Science.gov (United States)

    Tissues were collected, over a 10-year period, from broiler chickens diagnosed with severe H-SMS at the Georgia Poultry Lab, in Oakwood, GA. All samples were stored in tissue culture media, with antibiotics and 15% fetal bovine serum, in an ultra-cold freezer @ -80F. Specimens were homogenized,...

  9. Levels of fungi and mycotoxins in the samples of grain and grain dust collected from five various cereal crops in eastern Poland.

    Science.gov (United States)

    Krysińska-Traczyk, Ewa; Perkowski, Juliusz; Dutkiewicz, Jacek

    2007-01-01

    During combine harvesting of 5 various cereal crops (rye, barley, oats, buckwheat, corn) 24 samples of grain and 24 samples of settled grain dust were collected on farms located in the Lublin province of eastern Poland. The samples were examined for the concentration of total microfungi, Fusarium species, deoxynivalenol (DON), nivalenol (NIV), and ochratoxin A (OTA). Microfungi able to grow on malt agar were present in 79.2% of grain samples and in 91.7% of grain dust samples in the concentrations of 1.0-801.3x10(3) cfu/g and 1.5-12440.0x10(3) cfu/g, respectively. The concentration of microfungi in grain dust samples was significantly greater than in grain samples (pgrain samples and from 58.3% of grain dust samples in the concentrations of 0.1-375.0x10(3) cfu/g and 4.0-7,700.0x10(3) cfu/g, respectively. They were found in all samples of grain and grain dust from rye, barley and corn, but only in 0-16.7% of samples of grain and grain dust from oats and buckwheat. DON was found in 79.2% of grain samples and in 100% of grain dust samples in the concentrations of 0.001-0.18 microg/g and 0.006-0.283 microg/g, respectively. NIV was detected in 62.5% of grain samples and in 94.4% of grain dust samples in the concentrations of 0.004-0.502 microg/g and 0.005-0.339 microg/g, respectively. OTA was detected in 58.3% of grain samples and in 91.7% of grain dust samples in the concentrations of 0.00039- 0.00195 microg/g and 0.00036-0.00285 microg/g, respectively. The concentrations of DON, total fusariotoxins (DON+NIV) and OTA were significantly greater in grain dust samples than in grain samples (pgrain and dust was significantly correlated with the concentrations of DON (pgrain and dust was significantly correlated with the concentration of total fusariotoxins (pgrain dust collected from 5 various cereals on farms in eastern Poland was not large, the persistent presence of these mycotoxins in over 90% of examined samples poses a potential health risk of chronic respiratory

  10. Research-Grade 3D Virtual Astromaterials Samples: Novel Visualization of NASA's Apollo Lunar Samples and Antarctic Meteorite Samples to Benefit Curation, Research, and Education

    Science.gov (United States)

    Blumenfeld, E. H.; Evans, C. A.; Oshel, E. R.; Liddle, D. A.; Beaulieu, K. R.; Zeigler, R. A.; Righter, K.; Hanna, R. D.; Ketcham, R. A.

    2017-01-01

    NASA's vast and growing collections of astromaterials are both scientifically and culturally significant, requiring unique preservation strategies that need to be recurrently updated to contemporary technological capabilities and increasing accessibility demands. New technologies have made it possible to advance documentation and visualization practices that can enhance conservation and curation protocols for NASA's Astromaterials Collections. Our interdisciplinary team has developed a method to create 3D Virtual Astromaterials Samples (VAS) of the existing collections of Apollo Lunar Samples and Antarctic Meteorites. Research-grade 3D VAS will virtually put these samples in the hands of researchers and educators worldwide, increasing accessibility and visibility of these significant collections. With new sample return missions on the horizon, it is of primary importance to develop advanced curation standards for documentation and visualization methodologies.

  11. Period Changes of 23 Field RR Lyrae Stars

    Directory of Open Access Journals (Sweden)

    Soo-Chang Rey

    1994-12-01

    Full Text Available The secular period behavior of 23 field RR Lyrae stars is studied in order to determine if the observed period changes could be attributed, at least in the mean, to stellar evolution. The sample of stars is subdivided into two Oosterhoff groups based on the metallicity and period-shift. Despite the small sample size, we found a distinct bias toward positive period changes in the group variables. The period changes of the group variables in globular clusters. This provides yet another support for the Lee, Demarque, and Zinn(1990 evolutionary models of RR Lyrae stars and their explanation of the Sandage period-shift effect.

  12. 76 FR 24920 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-05-03

    ... precision requirements or power calculations that justify the proposed sample size, the expected response... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  13. 78 FR 74175 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2013-12-10

    ... precision requirements or power calculations that justify the proposed sample size, the expected response...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  14. 77 FR 52708 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2012-08-30

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Information Collection request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  15. Analysis of Dust Samples Collected from an Unused Spent Nuclear Fuel Interim Storage Container at Hope Creek, Delaware.

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Charles R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Enos, David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-03-01

    In July, 2014, the Electric Power Research Institute and industry partners sampled dust on the surface of an unused canister that had been stored in an overpack at the Hope Creek Nuclear Generating Station for approximately one year. The foreign material exclusion (FME) cover that had been on the top of the canister during storage, and a second recently - removed FME cover, were also sampled. This report summarizes the results of analyses of dust samples collected from the unused Hope Creek canister and the FME covers. Both wet and dry samples of the dust/salts were collected, using SaltSmart(TM) sensors and Scotch - Brite(TM) abrasive pads, respectively. The SaltSmart(TM) samples were leached and the leachate analyzed chemically to determine the composition and surface load per unit area of soluble salts present on the canister surface. The dry pad samples were analyzed by X-ray fluorescence and by scanning electron microscopy to determine dust texture and mineralogy; and by leaching and chemical analysis to deter mine soluble salt compositions. The analyses showed that the dominant particles on the canister surface were stainless steel particles, generated during manufacturing of the canister. Sparse environmentally - derived silicates and aluminosilicates were also present. Salt phases were sparse, and consisted of mostly of sulfates with rare nitrates and chlorides. On the FME covers, the dusts were mostly silicates/aluminosilicates; the soluble salts were consistent with those on the canister surface, and were dominantly sulfates. It should be noted that the FME covers were w ashed by rain prior to sampling, which had an unknown effect of the measured salt loads and compositions. Sulfate salts dominated the assemblages on the canister and FME surfaces, and in cluded Ca - SO4 , but also Na - SO4 , K - SO4 , and Na - Al - SO4 . It is likely that these salts were formed by particle - gas conversion reactions, either

  16. Transcriptome profiling of Finnsheep ovaries during out-of-season breeding period

    Directory of Open Access Journals (Sweden)

    Kisun Pokharel

    2015-03-01

    Full Text Available   Finnsheep is one of the most prolific sheep breeds in the world. We sequenced RNA-Seq libraries from the ovaries of Finnsheep ewes collected during out of season breeding period at about 30X sequence coverage. A total of 86 966 348 and 105 587 994 reads from two samples were mapped against latest available ovine reference genome (Oarv3.1. The transcriptome assembly revealed 14 870 known ovine genes, including the 15 candidate genes for fertility and out-of-season breeding. In this study we successfully used our bioinformatics pipeline to assemble the first ovarian transcriptome of Finnsheep.

  17. Effects of Blood Sample Collection Pre- and Post- Slaughter, Edta ...

    African Journals Online (AJOL)

    The samples were immediately subjected to Wet mount (WM), Haemotocrit centrifugation test (HCT) and Thin smear (TS) tests. The results revealed that, of the 100 samples examined, 19 (19%) were positive for the presence of Microfilaria spp while 6(6%) yielded Trypanosome spp. Of the 19 samples detected having ...

  18. 26 CFR 31.3401(b)-1 - Payroll period.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 15 2010-04-01 2010-04-01 false Payroll period. 31.3401(b)-1 Section 31.3401(b... Collection of Income Tax at Source § 31.3401(b)-1 Payroll period. (a) The term payroll period means the... elapsed and receives the remainder at the end of the week, the payroll period is still the calendar week...

  19. Determination of trace elements in lichen samples by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Saiki, Mitiko; Horimoto, Lidia K.; Vasconcellos, Marina B.A.; Marcelli, Marcelo P.; Sumita, Nairo M.; Saldiva, Paulo H.N.

    2001-01-01

    Samples of Canoparmelia texana lichen collected in different sites of Sao Paulo and Parana States, Brazil, were analysed by neutron activation analysis in order to obtain preliminary information on the air quality in these regions and also to select a region of interest for biomonitoring studies. Also Tadescantia pallida plant has been analysed in order to study the viability of using this specimen in environmental pollution monitoring. Lichens samples were collected from tree barks which were also collected to investigate the contribution of substrate derived elements to elements present in lichens. Young and old leaves of T. pallida were collected separately in order to study the leaf age effects on their elemental levels. The samples were cleaned, washed with distilled water, dried and ground for the analyses. Samples and standards were irradiated at the IEA-Rlm nuclear reactor for short and long periods and concentrations of the elements Al, As, Ca, Cd, Cl, Co, Cr, Cs, Fe, Hf, Mg, Mn, Rb, Sb, Sc, D, Th, U, V Zn and lanthanides were determined. Preliminary results obtained for T. texana lichen indicated that three sites (Ibiuna, Botanical Garden and Parque de Vila Velha) present low concentrations of the most elements analysed. Therefore lichens from these regions could be analysed to establish baseline levels of elements for monitoring purposes. Samples collected in open areas presented high concentrations of some elements probably due to the accumulation of elements originating from soil and from heavy vehicular traffic. Elemental concentrations obtained in outer barks were similar or smaller than those results obtained for lichens. Results obtained for T. pallida indicated that concentrations of elements in old leaves of this plant are of the same magnitude or slightly higher than those presented in young ones. (author)

  20. 76 FR 25693 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-05-05

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  1. Catch me if you can: Comparing ballast water sampling skids to traditional net sampling

    Science.gov (United States)

    Bradie, Johanna; Gianoli, Claudio; Linley, Robert Dallas; Schillak, Lothar; Schneider, Gerd; Stehouwer, Peter; Bailey, Sarah

    2018-03-01

    With the recent ratification of the International Convention for the Control and Management of Ships' Ballast Water and Sediments, 2004, it will soon be necessary to assess ships for compliance with ballast water discharge standards. Sampling skids that allow the efficient collection of ballast water samples in a compact space have been developed for this purpose. We ran 22 trials on board the RV Meteor from June 4-15, 2015 to evaluate the performance of three ballast water sampling devices (traditional plankton net, Triton sampling skid, SGS sampling skid) for three organism size classes: ≥ 50 μm, ≥ 10 μm to Natural sea water was run through the ballast water system and untreated samples were collected using paired sampling devices. Collected samples were analyzed in parallel by multiple analysts using several different analytic methods to quantify organism concentrations. To determine whether there were differences in the number of viable organisms collected across sampling devices, results were standardized and statistically treated to filter out other sources of variability, resulting in an outcome variable representing the mean difference in measurements that can be attributed to sampling devices. These results were tested for significance using pairwise Tukey contrasts. Differences in organism concentrations were found in 50% of comparisons between sampling skids and the plankton net for ≥ 50 μm, and ≥ 10 μm to < 50 μm size classes, with net samples containing either higher or lower densities. There were no differences for < 10 μm organisms. Future work will be required to explicitly examine the potential effects of flow velocity, sampling duration, sampled volume, and organism concentrations on sampling device performance.

  2. Susceptibility to tulathromycin in Mannheimia haemolytica isolated from feedlot cattle over a three-year period

    Directory of Open Access Journals (Sweden)

    Trevor W. Alexander

    2013-10-01

    Full Text Available Mannheimia haemolytica isolated from feedlot cattle were tested for tulathromycin resistance. Cattle were sampled over a three-year period, starting 12 months after approval of tulathromycin for prevention and treatment of bovine respiratory disease. Nasopharyngeal samples from approximately 5,814 cattle were collected when cattle entered feedlots (N = 4 and again from the same cattle after ≥ 60 d on feed. The antimicrobial use history for each animal was recorded. Mannheimia haemolytica was isolated from 796 (13.7% entry samples and 1,038 (20.6% ≥ 60 d samples. Of the cattle positive for M. haemolytica, 18.5%, 2.9%, and 2.4% were administered therapeutic concentrations of tulathromycin, tilmicosin, or tylosin tartrate, respectively. In addition, 13.2% were administered subtherapeutic concentrations of tylosin phosphate in feed. In years one and two, no tulathromycin-resistant M. haemolytica were detected, whereas 5 isolates (0.4% were resistant in year three. These resistant isolates were collected from three cattle originating from a single pen, were all serotype 1, and were genetically related (≥ 89% similarity according to pulsed-field gel electrophoreses patterns. The five tulathromycin-resistant isolates were multi-drug resistant also exhibiting resistance to oxytetracycline, tilmicosin, ampicillin, or penicillin. The macrolide resistance genes erm(42, erm(A, erm(B, erm(F, erm(X and msr(E-mph(E, were not detected in the tulathromycin-resistant M. haemolytica. This study showed that tulathromycin resistance in M. haemolytica from a general population of feedlot cattle in western Canada was low and did not change over a three-year period after tulathromycin was approved for use in cattle.

  3. NURE hydrogeochemical and stream sediment data release for pilot study samples from portions of the Sterling and Greeley NTMS Quadrangles, Colorado

    International Nuclear Information System (INIS)

    Nunes, H.P.

    1978-10-01

    During four distinct time periods between December 1976 and August 1977, students collected samples from the two areas. One purpose was to determine the effect of seasonal variations upon the elemental concentrations, particularly uranium

  4. NURE hydrogeochemical and stream sediment data release for pilot study samples from portions of the Sterling and Greeley NTMS Quadrangles, Colorado

    Energy Technology Data Exchange (ETDEWEB)

    Nunes, H.P.

    1978-10-01

    During four distinct time periods between December 1976 and August 1977, students collected samples from the two areas. One purpose was to determine the effect of seasonal variations upon the elemental concentrations, particularly uranium.

  5. Elevated Serum Hepcidin Levels during an Intensified Training Period in Well-Trained Female Long-Distance Runners.

    Science.gov (United States)

    Ishibashi, Aya; Maeda, Naho; Sumi, Daichi; Goto, Kazushige

    2017-03-14

    Iron is essential for providing oxygen to working muscles during exercise, and iron deficiency leads to decreased exercise capacity during endurance events. However, the mechanism of iron deficiency among endurance athletes remains unclear. In this study, we compared iron status between two periods involving different training regimens. Sixteen female long-distance runners participated. Over a seven-month period, fasting blood samples were collected during their regular training period (LOW; middle of February) and during an intensified training period (INT; late of August) to determine blood hematological, iron, and inflammatory parameters. Three-day food diaries were also assessed. Body weight and lean body mass did not differ significantly between LOW and INT, while body fat and body fat percentage were significantly lower in INT ( p daily diet were significantly higher during INT than LOW ( p daily intake of iron.

  6. Sampling and sample processing in pesticide residue analysis.

    Science.gov (United States)

    Lehotay, Steven J; Cook, Jo Marie

    2015-05-13

    Proper sampling and sample processing in pesticide residue analysis of food and soil have always been essential to obtain accurate results, but the subject is becoming a greater concern as approximately 100 mg test portions are being analyzed with automated high-throughput analytical methods by agrochemical industry and contract laboratories. As global food trade and the importance of monitoring increase, the food industry and regulatory laboratories are also considering miniaturized high-throughput methods. In conjunction with a summary of the symposium "Residues in Food and Feed - Going from Macro to Micro: The Future of Sample Processing in Residue Analytical Methods" held at the 13th IUPAC International Congress of Pesticide Chemistry, this is an opportune time to review sampling theory and sample processing for pesticide residue analysis. If collected samples and test portions do not adequately represent the actual lot from which they came and provide meaningful results, then all costs, time, and efforts involved in implementing programs using sophisticated analytical instruments and techniques are wasted and can actually yield misleading results. This paper is designed to briefly review the often-neglected but crucial topic of sample collection and processing and put the issue into perspective for the future of pesticide residue analysis. It also emphasizes that analysts should demonstrate the validity of their sample processing approaches for the analytes/matrices of interest and encourages further studies on sampling and sample mass reduction to produce a test portion.

  7. Chemometrics methods for the investigation of methylmercury and total mercury contamination in mollusks samples collected from coastal sites along the Chinese Bohai Sea

    International Nuclear Information System (INIS)

    Wang Yawei; Liang Lina; Shi Jianbo; Jiang Guibin

    2005-01-01

    The development and application of chemometrics methods, principal component analysis (PCA), cluster analysis and correlation analysis for the determination of methylmercury (MeHg) and total mercury (HgT) in gastropod and bivalve species collected from eight coastal sites along the Chinese Bohai Sea are described. HgT is directly determined by atomic fluorescence spectrometry (AFS), while MeHg is measured by a laboratory established high performance liquid chromatography-atomic fluorescence spectrometry system (HPLC-AFS). One-way ANOVA and cluster analysis indicated that the bioaccumulation of Rap to accumulate Hg was significantly (P<0.05) different from other mollusks. Correlation analysis shows that there is linear relationship between MeHg and HgT in mollusks samples collected from coastal sites along the Chinese Bohai Sea, while in mollusks samples collected from Hongqiao market in Beijing City, there is not any linear relationship. - Rapana venosa might be used as a potential biomonitor for Hg pollution in the Bohai Sea, China

  8. Work Sampling Study of an Engineering Professor during a Regular Contract Period

    Science.gov (United States)

    Brink, Jan; McDonald, Dale B.

    2015-01-01

    Work sampling is a technique that has been employed in industry and fields such as healthcare for some time. It is a powerful technique, and an alternative to conventional stop watch time studies, used by industrial engineers to focus upon random work sampling observations. This study applies work sampling to the duties performed by an individual…

  9. INAA of Airborne Particulate Matter Collected in Bangkok and Pathumthani 2002-2004

    International Nuclear Information System (INIS)

    Chueinta, W.; Bunprapob, S.

    2005-01-01

    This paper presents the summary report of the monitoring study on ambient air quality in Bangkok metropolis and its boundary covering the period from 2002 to 2004. The work performed included sampling of fine and coarse fractions of particulate matter at the sites representing urban and suburban areas; measurement of particle mass concentration and elemental concentration; and data interpretation. Instrumental neutron activation by use of research reactor facilities at Office of Atoms for Peace was carried out for multielemental analysis of all filter samples collected. Twenty elements were determined. The database of the three consecutive years are summarized and reviewed in this paper

  10. Estimates of Radionuclide Loading to Cochiti Lake from Los Alamos Canyon Using Manual and Automated Sampling

    Energy Technology Data Exchange (ETDEWEB)

    McLean, Christopher T. [Univ. of New Mexico, Albuquerque, NM (United States)

    2000-07-01

    Los Alamos National Laboratory has a long-standing program of sampling storm water runoff inside the Laboratory boundaries. In 1995, the Laboratory started collecting the samples using automated storm water sampling stations; prior to this time the samples were collected manually. The Laboratory has also been periodically collecting sediment samples from Cochiti Lake. This paper presents the data for Pu-238 and Pu-239 bound to the sediments for Los Alamos Canyon storm water runoff and compares the sampling types by mass loading and as a percentage of the sediment deposition to Cochiti Lake. The data for both manual and automated sampling are used to calculate mass loads from Los Alamos Canyon on a yearly basis. The automated samples show mass loading 200- 500 percent greater for Pu-238 and 300-700 percent greater for Pu-239 than the manual samples. Using the mean manual flow volume for mass loading calculations, the automated samples are over 900 percent greater for Pu-238 and over 1800 percent greater for Pu-239. Evaluating the Pu-238 and Pu-239 activities as a percentage of deposition to Cochiti Lake indicates that the automated samples are 700-1300 percent greater for Pu- 238 and 200-500 percent greater for Pu-239. The variance was calculated by two methods. The first method calculates the variance for each sample event. The second method calculates the variances by the total volume of water discharged in Los Alamos Canyon for the year.

  11. Apollo Lunar Sample Photographs: Digitizing the Moon Rock Collection

    Science.gov (United States)

    Lofgren, Gary E.; Todd, Nancy S.; Runco, S. K.; Stefanov, W. L.

    2011-01-01

    The Acquisition and Curation Office at JSC has undertaken a 4-year data restoration project effort for the lunar science community funded by the LASER program (Lunar Advanced Science and Exploration Research) to digitize photographs of the Apollo lunar rock samples and create high resolution digital images. These sample photographs are not easily accessible outside of JSC, and currently exist only on degradable film in the Curation Data Storage Facility

  12. Physical sampling for site and waste characterization

    International Nuclear Information System (INIS)

    Bonnough, T.L.

    1994-01-01

    Physical sampling plays a basic role in site and waste characterization program effort. The term ''physical sampling'' used here means collecting tangible, physical samples of soil, water, air, waste streams, or other materials. The industry defines the term ''physical sampling'' broadly to include measurements of physical conditions such as temperature, wind conditions, and pH which are also often taken in a sample collection effort. Most environmental compliance actions are supported by the results of taking, recording, and analyzing physical samples and the measuring of physical conditions taken in association with sample collecting

  13. Long-period structures in gold-copper alloys; Structures a longues periodes dans les alliages or-cuivre

    Energy Technology Data Exchange (ETDEWEB)

    Jehanno, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    We first proceed to reevaluation of the gold-copper equilibrium diagram for alloys between Au{sub 20}Cu{sub 80} and Au{sub 65}Cu{sub 35}. The identification of the various phases was performed by X-rays diffraction on quenched polycrystalline samples. We next study the structure of the phase AuCuII. X-ray data collected from bulk single crystals show that this long-period structure must be described with the help of two correlated periodic functions: an 'order function' and a 'displacement function'. The 'order function' conciliates the non-integer value of the period with its rigorous definition. The 'displacement function' accounts for the dis-symmetries of the observed intensities for the antiphase homologous reflections as the appearance of satellites around the fundamental reflections. These two functions are remarkably well defined at long distance in carefully annealed samples and, in some conditions, can be obtained independently. We observe that the improvement of the degree of order increases the 'modulation of position'. In the case of non stoichiometric alloys, the excess of gold atoms (gold rich alloys) is distributed at random whereas the excess of copper (copper rich alloys) is distributed in a preferential manner close to the antiphase boundaries. (author) [French] Nous procedons, tout d'abord, a une reevaluation du diagramme d'equilibre des alliages or-cuivre compris entre Au{sub 20}Cu{sub 80} et Au{sub 65}Cu{sub 35}. L'identification des differentes phases s'est faite par diffraction de rayons X sur des echantillons polycristallins trempes. Nous etudions ensuite, aux rayons X, la structure de la phase AuCuII. Les donnees rassemblees sur monocristaux massifs indiquent que cette structure a longue periode doit etre decrite a l'aide de deux fonctions periodiques correlees: une fonction d'ordre et une fonction de deplacement des atomes. La fonction d'ordre concilie le caractere non entier de la periode avec sa rigoureuse definition. La fonction de

  14. Determination of the activity concentration levels of the artificial radionuclide137Cs in soil samples collected from Qatar using high-resolution gamma-ray spectrometry

    Science.gov (United States)

    Al-Sulaiti, Huda; Nasir, Tabassum; Al Mugren, K. S.; Alkhomashi, N.; Al-Dahan, N.; Al-Dosari, M.; Bradley, D. A.; Bukhari, S.; Regan, P. H.; Santawamaitre, T.; Malain, D.; Habib, A.; Al-Dosari, Hanan; Daar, Eman

    2016-09-01

    The goal of this study was to establish the first baseline measurements for radioactivity concentration of the artificial radionuclide 137Cs in soil samples collected from the Qatarian peninsula. The work focused on the determination of the activity concentrations levels of man-made radiation in 129 soil samples collected across the landscape of the State of Qatar. All the samples were collected before the most recent accident in Japan, “the 2011 Fukushima Dai-ichi nuclear power plant accident”. The activity concentrations have been measured via high-resolution gamma-ray spectrometry using a hyper-pure germanium detector situated in a low-background environment with a copper inner-plated passive lead shield. A radiological map showing the activity concentrations of 137Cs is presented in this work. The concentration wasfound to range from 0.21 to 15.41 Bq/kg. The highest activity concentration of 137Cs was observed in sample no. 26 in North of Qatar. The mean value was found to be around 2.15 ± 0.27 Bq/kg. These values lie within the expected range relative to the countries in the region. It is expected that this contamination is mainly due to the Chernobyl accident on 26 April 1986, but this conclusion cannot be confirmed because of the lack of data before this accident.

  15. Toxicity evaluation of natural samples from the vicinity of rice fields using two trophic levels.

    Science.gov (United States)

    Marques, Catarina R; Pereira, Ruth; Gonçalves, Fernando

    2011-09-01

    An ecotoxicological screening of environmental samples collected in the vicinity of rice fields followed a combination of physical and chemical measurements and chronic bioassays with two freshwater trophic levels (microalgae: Pseudokirchneriella subcapitata and Chlorella vulgaris; daphnids: Daphnia longispina and Daphnia magna). As so, water and sediment/soil elutriate samples were obtained from three sites: (1) in a canal reach crossing a protected wetland upstream, (2) in a canal reach surrounded by rice fields and (3) in a rice paddy. The sampling was performed before and during the rice culture. During the rice cropping, the whole system quality decreased comparatively to the situation before that period (e.g. nutrient overload, the presence of pesticides in elutriates from sites L2 and L3). This was reinforced by a significant inhibition of both microalgae growth, especially under elutriates. Contrary, the life-history traits of daphnids were significantly stimulated with increasing concentrations of water and elutriates, for both sampling periods.

  16. Postpartum responses of dairy cows supplemented with n-3 fatty acids for different durations during the peripartal period.

    Science.gov (United States)

    Badiei, A; Aliverdilou, A; Amanlou, H; Beheshti, M; Dirandeh, E; Masoumi, R; Moosakhani, F; Petit, H V

    2014-10-01

    The objective of this study was to determine the effect of different durations of n-3 supplementation during the peripartal period on production and reproduction performance of Holstein dairy cows. Thirty-two Holstein dry cows (16 multiparous and 16 primiparous) were blocked within parity for similar expected calving dates 8 wk before calving. Cows within blocks were assigned randomly to 1 of 4 treatments: (1) control without n-3 fatty acid (FA) supplementation during the dry period; (2) n-3 FA supplementation during the whole dry period (8 wk); and (3) n-3 FA supplementation during the early dry period (first 5 wk; far-off), or (4) n-3 FA supplementation during the late dry period (last 3 wk; close-up). All cows received the same diet without n-3 FA after calving for the first 6 wk of lactation. Ovaries of each cow were examined 10, 17, 24, and 34 d from calving (calving=d 0) by transrectal ultrasonography to determine follicular development. Blood samples were collected at 14-d intervals starting on the first day of the dry period (8 wk before expected calving) to determine plasma concentrations of glucose, β-hydroxybutyrate, nonesterified fatty acids, urea N, aspartate aminotransferase, and insulin. Blood samples were also collected on d 1, 10, 17, 24, 31, and 38 postpartum for determination of progesterone concentration. Milk yield was recorded daily throughout the experiment and samples were taken twice weekly (Monday and Thursday mornings) for analysis of fat, protein, and lactose. Yields of milk and 4% fat-corrected milk and milk composition were similar among treatments except for fat proportion, which tended to be lower in cows that were fed n-3 FA throughout the dry period. We observed no differences among treatments for plasma concentrations of metabolites and hormones. The cows that were fed in the 3 n-3 FA treatments had larger ovulatory follicles compared with those fed the controlled diet. Treatments did not differ significantly in terms of the

  17. A confirmatory test of the underlying factor structure of scores on the collective self-esteem scale in two independent samples of Black Americans.

    Science.gov (United States)

    Utsey, Shawn O; Constantine, Madonna G

    2006-04-01

    In this study, we examined the factor structure of the Collective Self-Esteem Scale (CSES; Luhtanen & Crocker, 1992) across 2 separate samples of Black Americans. The CSES was administered to a sample of Black American adolescents (n = 538) and a community sample of Black American adults (n = 313). Results of confirmatory factor analyses (CFAs), however, did not support the original 4-factor model identified by Luhtanen and Crocker (1992) as providing an adequate fit to the data for these samples. Furthermore, an exploratory CFA procedure failed to find a CSES factor structure that could be replicated across the 2 samples of Black Americans. We present and discuss implications of the findings.

  18. Systematic sampling with errors in sample locations

    DEFF Research Database (Denmark)

    Ziegel, Johanna; Baddeley, Adrian; Dorph-Petersen, Karl-Anton

    2010-01-01

    analysis using point process methods. We then analyze three different models for the error process, calculate exact expressions for the variances, and derive asymptotic variances. Errors in the placement of sample points can lead to substantial inflation of the variance, dampening of zitterbewegung......Systematic sampling of points in continuous space is widely used in microscopy and spatial surveys. Classical theory provides asymptotic expressions for the variance of estimators based on systematic sampling as the grid spacing decreases. However, the classical theory assumes that the sample grid...... is exactly periodic; real physical sampling procedures may introduce errors in the placement of the sample points. This paper studies the effect of errors in sample positioning on the variance of estimators in the case of one-dimensional systematic sampling. First we sketch a general approach to variance...

  19. An Exploratory Investigation of the Periodic Performance Evaluation Processes for Marketing Faculty: A Comparison of Doctoral-Granting and Non-Doctoral-Granting Universities

    Science.gov (United States)

    Shepherd, C. David; Carley, Susan S.; Stuart, Randy S.

    2009-01-01

    Whether a first entrant into the academic job market or a seasoned professional, career outcomes for marketing educators depend heavily on the evaluation process used at their institutions. This research explores the periodic performance evaluation process for marketing faculty members using data collected from a national sample of marketing…

  20. 75 FR 39200 - Periodic Reporting

    Science.gov (United States)

    2010-07-08

    ... unit.'' According to the Postal Service, delivery units would include ``city and rural carriers, box sections, and firms.'' Petition, Attachment Proposal Two-B, at 1. Currently, ODIS-RPW sample frame units... continue to be collected at the current sample size. The attachments to the Postal Service's petition...

  1. Data Validation Package June 2016 Groundwater and Surface Water Sampling at the Old and New Rifle, Colorado, Processing Sites September 2016

    Energy Technology Data Exchange (ETDEWEB)

    Bush, Richard [USDOE Office of Legacy Management (LM), Washington, DC (United States); Lemke, Peter [Navarro Research and Engineering, Inc., Oak Ridge, TN (United States)

    2016-10-17

    Sampling Period: June 14–17 and July 7, 2016. Water samples were collected from 36 locations at New Rifle and Old Rifle, Colorado, Disposal/Processing Sites. Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. Duplicate samples were collected from New Rifle locations 0216 and 0855, and Old Rifle location 0655. One equipment blank was collected after decontamination of non-dedicated equipment used to collect one surface water sample. See Attachment 2, Trip Report for additional details. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and- analysis-plan-us-department-energy-office-legacy-management-sites). New Rifle Site Samples were collected at the New Rifle site from 16 monitoring wells and 7 surface locations in compliance with the December 2008 Groundwater Compliance Action Plan [GCAP] for the New Rifle, Colorado, Processing Site (LMS/RFN/S01920). Monitoring well 0216 could not be sampled in June because it was surrounded by standing water due to the high river stage from spring runoff, it was later sampled in July. Monitoring well 0635 and surface location 0322 could not be sampled because access through the elk fence along Interstate 70 has not been completed at this time. Old Rifle Site Samples were collected at the Old Rifle site from eight monitoring wells and five surface locations in compliance with the December 2001 Ground Water Compliance Action Plan for the Old Rifle, Colorado, UMTRA Project Site (GJ0-2000-177-TAR).

  2. Surface water/groundwater relationship in Chaj Doab. Final report for the period November 1985 - December 1989

    Energy Technology Data Exchange (ETDEWEB)

    Hussain, S D [Pakistan Inst. of Nuclear Science and Technology, Islamabad (Pakistan)

    1990-12-31

    In order to understand the relationship between surface water and groundwater in Chaj Doab area, isotopic and chemical studies were undertaken. Seven sets of water samples from hand pumps, tube wells, rivers and canals were collected during the period November 1985 to October 1988 and all the samples were analysed for environmental isotopes such as {sup 2}H, {sup 3}H, {sup 18}O and the dissolved chemical constituents like Na{sup +}, K{sup +}, Ca{sup ++}, Mg{sup ++}, Cl{sup -}, NO{sub 3}{sup -}, SO{sub 4}{sup --} and TIC. Some of the water samples having very low tritium concentrations were analysed for {sup 14}C content. Analysis for {sup 13}C values for two sets of samples was also carried out. 8 refs, 13 figs, 6 tabs.

  3. Intratypic differentiation of polioviruses isolated from suspected cases of poliomyelitis in Brazil during the period of 1990 to 1993

    Directory of Open Access Journals (Sweden)

    A. M. B. de Filippis

    1994-12-01

    Full Text Available This study analyzed 3129 fecal samples derived from 1626 patients with sudden onset acute flaccid paralysis clinically compatible with poliomyelitis. The samples were collected in the period ranging from January 1990 to September 1993 in all regions of Brazil. Among the 1626 cases studied, 196 had isolation of poliovirus. Nevertheless, it was observed that some factors influenced the isolation rate and the intratypic characterization of these polioviruses. No cases of acute flaccid paralysis has been found to be etiologically related with wild polioviruses.

  4. Comparison of precipitation chemistry measurements obtained by the Canadian Air and Precipitation Monitoring Network and National Atmospheric Deposition Program for the period 1995-2004

    Science.gov (United States)

    Wetherbee, Gregory A.; Shaw, Michael J.; Latysh, Natalie E.; Lehmann, Christopher M.B.; Rothert, Jane E.

    2010-01-01

    Precipitation chemistry and depth measurements obtained by the Canadian Air and Precipitation Monitoring Network (CAPMoN) and the US National Atmospheric Deposition Program/National Trends Network (NADP/NTN) were compared for the 10-year period 1995–2004. Colocated sets of CAPMoN and NADP instrumentation, consisting of precipitation collectors and rain gages, were operated simultaneously per standard protocols for each network at Sutton, Ontario and Frelighsburg, Ontario, Canada and at State College, PA, USA. CAPMoN samples were collected daily, and NADP samples were collected weekly, and samples were analyzed exclusively by each network’s laboratory for pH, H + , Ca2+  , Mg2+  , Na + , K + , NH+4 , Cl − , NO−3 , and SO2−4 . Weekly and annual precipitation-weighted mean concentrations for each network were compared. This study is a follow-up to an earlier internetwork comparison for the period 1986–1993, published by Alain Sirois, Robert Vet, and Dennis Lamb in 2000. Median weekly internetwork differences for 1995–2004 data were the same to slightly lower than for data for the previous study period (1986–1993) for all analytes except NO−3 , SO2−4 , and sample depth. A 1994 NADP sampling protocol change and a 1998 change in the types of filters used to process NADP samples reversed the previously identified negative bias in NADP data for hydrogen-ion and sodium concentrations. Statistically significant biases (α = 0.10) for sodium and hydrogen-ion concentrations observed in the 1986–1993 data were not significant for 1995–2004. Weekly CAPMoN measurements generally are higher than weekly NADP measurements due to differences in sample filtration and field instrumentation, not sample evaporation, contamination, or analytical laboratory differences.

  5. Assessment of reagent effectiveness and preservation methods for equine faecal samples

    Directory of Open Access Journals (Sweden)

    Eva Vavrouchova

    2015-03-01

    Full Text Available The aim of our study was to identify the most suitable flotation solution and effective preservation method for the examination of equine faeces samples using the FLOTAC technique. Samples from naturally infected horses were transported to the laboratory andanalysed accordingly. The sample from each horse was homogenized and divided into four parts: one was frozen, another two were preserved in different reagents such as sodium acetate-acetic-acid–formalin (SAF or 5% formalin.The last part was examined as a fresh sample in three different flotation solutions (Sheather´s solution, sodium chloride and sodium nitrate solution, all with a specific gravity 1.200. The preserved samples were examined in the period from 14 to21days after collection. According to our results, the sucrose solution was the most suitable flotation solution for fresh samples (small strongyle egg per gram was 706 compared to 360 in sodium chlorid and 507 in sodium nitrate and the sodium nitrate solution was the most efficient for the preserved samples (egg per gram was 382 compared to 295 in salt solution and 305 in sucrose solution. Freezing appears to be the most effective method of sample preservation, resulting in minimal damage to fragile strongyle eggs and therefore it is the most simple and effective preservation method for the examination of large numbers of faecal samples without the necessity of examining them all within 48 hours of collection. Deep freezing as a preservation method for equine faeces samples has not, according to our knowledge, been yet published.

  6. Physical sampling for site and waste characterization

    International Nuclear Information System (INIS)

    Bonnough, T.L.

    1996-01-01

    Physical sampling plays a basic role in high-level radioactive waste management program effort. The term ''physical sampling'' used here means collecting tangible, physical samples of soil, water, air, waste streams, or other materials. The industry defines the term ''physical sampling'' broadly to include measurements of physical conditions such as temperature, wind conditions, and pH, which are also often taken in a sample collection effort. Most environmental compliance actions are supported by the results of taking, recording, and analyzing physical samples and the measurements of physical conditions taken in association with sample collecting. Therefore, the when and how to take samples is needed to be known and planned

  7. Insights into explosion dynamics at Stromboli in 2009 from ash samples collected in real-time

    Science.gov (United States)

    Taddeucci, J.; Lautze, N.; Andronico, D.; D'Auria, L.; Niemeijer, A.; Houghton, B.; Scarlato, P.

    2012-04-01

    Rapid characterization of tephra during explosive eruptions can provide valuable insights into eruptive mechanisms, also integrating other monitoring systems. Here we reveal a perspective on Stromboli's conduit processes by linking ash textures to geophysical estimates of eruption parameters of observed explosions. A three day campaign at Stromboli was undertaken by Italy's Istituto Nazionale di Geofisica e Vulcanologia (INGV) in October 2009. At this time activity was moderately intense, with an average 4 to 5, both ash-rich and ash-poor, explosions per hour at each the SW and NE vents. A total of fifteen ash samples were collected in real time. We used binocular and scanning electron microscopes to analyze the components, grain size and morphology distributions, and surface chemistry of ash particles within eight selected samples. In addition, the INGV monitoring network provided visual, thermal, and seismic information on the explosions that generated the sampled ash. In each sample, the proportion of fluidal, glassy sideromelane (as opposed to blocky, microcrystalline tachylite plus lithics), the degree of "chemical freshness" (as opposed to chemical alteration), and the average size of particles appear to correlate directly with the maximum height and the seismic amplitude of the corresponding explosion, and inversely correlate with the amount of ash erupted, as estimated by monitoring videos. These observations suggest that more violent explosions (i.e., those driven by the release of larger and more pressurized gas volumes) produce ash via the fragmentation of hotter, more fluid magma, while weaker ones mostly erupt ash-sized particles derived by the fragmentation of colder magma and incorporation of conduit wall debris. The formation of fluidal ash particles (up to Pele's hairs) requires aerodynamic deformation of a relatively low-viscosity magma, in agreement with the strong acceleration imposed upon fragmented magma clots by the rapid expansion of

  8. Seed germination from lowland tapir (Tapirus terrestris) fecal samples collected during the dry season in the Northern Brazilian Amazon.

    Science.gov (United States)

    Barcelos, Adriana Renata; Bobrowiec, Paulo Estefano D; Sanaiotti, Tânia Margarete; Gribel, Rogério

    2013-03-01

    This study evaluated the potential of lowland tapirs as seed dispersers in the northern Brazilian Amazon. The study analyzed the viability of seeds after passage through the gut. Fecal samples were collected from 6 different vegetation physiognomies in Viruá National Park during the dry season. The samples were then kept in a greenhouse for 16 months to allow the seeds to germinate. The seedling species were identified and classified according to the type of fruit, plant habit, seed size and type of ingestion. Of the 111 fecal samples, 94 (84.7%) had viable seeds of 75 species. Melastomataceae was the most frequent family with viable seeds in the fecal samples (69.1% of samples, N= 18 species). The data suggest that the importance of the lowland tapirs as dispersers is not restricted to the species consumed actively by frugivory but also extends to species accidentally consumed during browsing. The occurrence of both large and small viable seeds in the fecal samples as well as a number of large drupes, which probably cannot be transported via endozoochory by any other animal species, provide evidence of the ecological importance of lowland tapirs to the dynamics of the forest-campinarana vegetation mosaic in the region. © 2012 Wiley Publishing Asia Pty Ltd, ISZS and IOZ/CAS.

  9. Preliminary study of elemental mass size distribution of urban aerosol collected in Debrecen

    International Nuclear Information System (INIS)

    Kertesz, Zs.; Borbely-Kiss, I.; Kiss, A.Z.; Koltay, E.; Szabo, Gy.

    2000-01-01

    Complete text of publication follows. Aerosol sampling campaigns were performed during January-February 1998 and August 1998 at an urban location (in the yard of the Institute of Nuclear Research), where aerosol sampling has been carried out continuously since 1991 with single stage Nuclepore filter holders, and since 1994 with 2-stage Gent stacked filter units (SFU). In the winter period in four weekdays 24-hours samplings were performed with a 7-stage PIXE International Cascade Impactor (PCI) and simultaneously with a SFU. On 19-25 August 1998, a week-long aerosol sampling campaign was carried out with the PCI (24-hour samplings), a SFU (24-hour samplings), and a streaker sampler (168-hour continuous sampling). For this period meteorological data were also obtained by a micro-meteorological station installed at the same location by the Radon Group. Elemental concentrations for Al, Si, P, S, Cl, K, Ca, Ti, V, Mn, Fe, Ni, Cu, Zn, Ba and Pb of the aerosol samples were determined by PIXE using the 2 MeV energy proton beam of the 5 MeV Van de Graaff accelerator of the Institute. The obtained average elemental concentrations and the seasonal variation in the elemental concentrations show good correlation with the results obtained from the analysis of the samples collected in previous years. In winter the elemental concentrations are usually lower than in summer, except Cl. The Cl concentration in the coarse fraction is higher with a factor of 10 than in summer due to the salting of the roads and pavements. The summer period included a long weekend with a national holiday. During the weekend the elemental concentrations and also the total mass decreased, and in the beginning of the following week it started to increase. Size distribution: the impactor we have used separate the aerosol within the size range of 0.25 μm and 30 μm into 7 fractions. The mass size distribution for elements of natural origin, like Si, Ca, Ti, Fe, and Mn has one mode: the coarse mode. The

  10. Assessment of different methods of bovine oocytes collection, maturation and in vitro fertilization of abattoir specimens

    Directory of Open Access Journals (Sweden)

    W.M. Saleh

    2017-06-01

    Full Text Available The aim of this study is designed to evaluate the best methods for cow oocytes collection from abattoir specimens which is the cheapest, easily obtained and bulky number. Forty five fresh cow genitalia specimens and testicle were collected directly after slaughter from Al-Shoáalla abattoir north-west of Baghdad the capital early morning, transported in cool box under (4-8 °C to the laboratory of theriogenology in the College of Veterinary Medicine/Baghdad University during the period from November 2016 to February 2017. Ovaries were separated from the surrounding tissues, washed thoroughly with dis. water repeatedly, then with normal saline and finally with MEM medium containing Antibiotics and Nystatin for contaminant elimination. Oocytes were collected with four methods aspiration, slashing, slicing after aspiration and slicing. The result showed that; the collected oocytes were 55, 68, 87 and 106 oocytes respectively; slicing methods yield more oocytes count. Period of time between slaughtering and samples processing significantly affect oocytes collected percentage and quality, periods as 2, 6, 12 and 24 hours yield 75%, 68%, 61% and 55% oocytes counts of good, fair, poor to aged and bad quality oocytes respectively. Two hours period yield an elevated oocytes count with good quality. Maturation index of oocytes according to the type of collected methods showed 44, 37, 39 and 42 with 12, 8, 6 and 6 good oocyte quality for the four methods respectively. In conclusion slicing methods yield more oocytes count with a moderate quality and embryos production while aspiration methods yield a moderate oocytes count with an elevated quality and good embryos production.

  11. Storm water monitoring report for the 1995 reporting period

    International Nuclear Information System (INIS)

    Braun, D.R.; Brock, T.A.

    1995-10-01

    This report includes sampling results and other relevant information gathered in the past year by LITCO's Environmental Monitoring and Water Resources Unit. This report presents analytical data collected from storm water discharges as a part of the Environmental Monitoring Storm Water Monitoring Program for 1994--1995 for facilities located on the Idaho National Engineering Laboratory (INEL). The 1995 reporting period is October 1, 1994 through September 30, 1995. The storm water monitoring program tracks information about types and amounts of pollutants present. Data are required for the Environmental Protection Agency and are transmitted via Discharge Monitoring Reports. Additional information resulting from the program contributes to Best Management Practice to control pollution in runoff as well as Storm Water Pollution Prevention Plans

  12. 76 FR 35069 - Agency Information Collection Activities; Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-06-15

    ... precision requirements or power calculations that justify the proposed sample size, the expected response...; Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...

  13. The WAIS Melt Monitor: An automated ice core melting system for meltwater sample handling and the collection of high resolution microparticle size distribution data

    Science.gov (United States)

    Breton, D. J.; Koffman, B. G.; Kreutz, K. J.; Hamilton, G. S.

    2010-12-01

    Paleoclimate data are often extracted from ice cores by careful geochemical analysis of meltwater samples. The analysis of the microparticles found in ice cores can also yield unique clues about atmospheric dust loading and transport, dust provenance and past environmental conditions. Determination of microparticle concentration, size distribution and chemical makeup as a function of depth is especially difficult because the particle size measurement either consumes or contaminates the meltwater, preventing further geochemical analysis. Here we describe a microcontroller-based ice core melting system which allows the collection of separate microparticle and chemistry samples from the same depth intervals in the ice core, while logging and accurately depth-tagging real-time electrical conductivity and particle size distribution data. This system was designed specifically to support microparticle analysis of the WAIS Divide WDC06A deep ice core, but many of the subsystems are applicable to more general ice core melting operations. Major system components include: a rotary encoder to measure ice core melt displacement with 0.1 millimeter accuracy, a meltwater tracking system to assign core depths to conductivity, particle and sample vial data, an optical debubbler level control system to protect the Abakus laser particle counter from damage due to air bubbles, a Rabbit 3700 microcontroller which communicates with a host PC, collects encoder and optical sensor data and autonomously operates Gilson peristaltic pumps and fraction collectors to provide automatic sample handling, melt monitor control software operating on a standard PC allowing the user to control and view the status of the system, data logging software operating on the same PC to collect data from the melting, electrical conductivity and microparticle measurement systems. Because microparticle samples can easily be contaminated, we use optical air bubble sensors and high resolution ice core density

  14. An airborne meteorological data collection system using satellite relay /ASDAR/

    Science.gov (United States)

    Bagwell, J. W.; Lindow, B. G.

    1978-01-01

    The paper describes the aircraft to satellite data relay (ASDAR) project which processes information collected by the navigation and data systems of widebody jet aircraft which cross data-sparse areas of the tropics and southern hemisphere. The ASDAR system consists of a data acquisition and control unit to acquire, store, and format latitude, longitude, altitude, wind speed, wind direction, and outside air temperature data; a transmitter to relay the formatted data via satellite to the ground; and a clock to time the data sampling and transmission periods.

  15. Alleles of Ppd-D1 gene in the collection of Aegilops tauschii accessions and bread wheat varieties

    Directory of Open Access Journals (Sweden)

    Babenko D. O.

    2012-04-01

    Full Text Available Light period significantly influences on the growth and development of plants. One of the major genes of photoperiod sensitivity is Ppd-D1, located on the chromosome 2D. The aim of the work was to determine the alleles and molecular structure of Ppd-D1 gene in samples from the collection of Ae. tauschii accessions, which have different flowering periods, and in 29 Ukrainian wheat varieties. Methods. We used methods of allele-specific PCR with primers to the Ppd-D1 gene, sequencing and Blast-analysis. Results. The collection of Ae. tauschii accessions and several varieties of winter and spring wheat was studied. The molecular structure of the allelic variants (414, 429 and 453 b. p. of Ppd-D1b gene was determined in the collection of Aegilops. tauschii accessions. Conclusions. The Ppd-D1a allele was present in all studied varieties of winter wheat. 60 % of spring wheat is characterized by Ppd-D1b allele (size of amplification products 414 b. p.. Blast-analysis of the sequence data banks on the basis of the reference sequence of sample k-1322 from the collection of Ae. tauschii accessions has shown a high homology (80 to 100 % between the nucleotide sequences of PRR genes, that characterize the A and D genomes of representatives of the genera Triticum and Aegilops.

  16. Household vacuum cleaners vs. the high-volume surface sampler for collection of carpet dust samples in epidemiologic studies of children

    Directory of Open Access Journals (Sweden)

    Buffler Patricia A

    2008-02-01

    Full Text Available Abstract Background Levels of pesticides and other compounds in carpet dust can be useful indicators of exposure in epidemiologic studies, particularly for young children who are in frequent contact with carpets. The high-volume surface sampler (HVS3 is often used to collect dust samples in the room in which the child had spent the most time. This method can be expensive and cumbersome, and it has been suggested that an easier method would be to remove dust that had already been collected with the household vacuum cleaner. However, the household vacuum integrates exposures over multiple rooms, some of which are not relevant to the child's exposure, and differences in vacuuming equipment and practices could affect the chemical concentration data. Here, we compare levels of pesticides and other compounds in dust from household vacuums to that collected using the HVS3. Methods Both methods were used in 45 homes in California. HVS3 samples were collected in one room, while the household vacuum had typically been used throughout the home. The samples were analyzed for 64 organic compounds, including pesticides, polycyclic aromatic hydrocarbons, and polychlorinated biphenyls (PCBs, using GC/MS in multiple ion monitoring mode; and for nine metals using conventional microwave-assisted acid digestion combined with ICP/MS. Results The methods agreed in detecting the presence of the compounds 77% to 100% of the time (median 95%. For compounds with less than 100% agreement, neither method was consistently more sensitive than the other. Median concentrations were similar for most analytes, and Spearman correlation coefficients were 0.60 or higher except for allethrin (0.15 and malathion (0.24, which were detected infrequently, and benzo(kfluoranthene (0.55, benzo(apyrene (0.55, PCB 105 (0.54, PCB 118 (0.54, and PCB 138 (0.58. Assuming that the HVS3 method is the "gold standard," the extent to which the household vacuum cleaner method yields relative risk

  17. OCCURRENCE OF LISTERIA MONOCYTOGENES IN READY TO EAT FOOD SAMPLES COLLECTED BY LOMBARDY REGION HEALTH AUTHORITIES IN 2009-2010

    Directory of Open Access Journals (Sweden)

    E. Oliverio

    2012-08-01

    Full Text Available The study provides data on the prevalence of Listeria monocytogenes in ready-to-eat food samples collected by Lombardy region health authorities and analyzed by Department of Food Microbiology, Istituto Zooprofilattico Sperimentale della Lombardia e dell’Emilia Romagna. From the total of 503 food samples analyzed, the pathogen was detected in 85 (16,9%. In particular it was highlighted in 8/152 (5,3% meat products, in 5/245 (2% dairy products and in 42/106 (39,6% fishery products. Given the considerable public health implications, the study confirms that a well-planned program of listeriosis surveillance should be enforced to suitably estimate the burden of disease and to prevent foodborne outbreaks.

  18. An improved test for periodicity

    International Nuclear Information System (INIS)

    Davies, S.R.

    1990-01-01

    I discuss two widely used methods of testing for periodicity, phase dispersion minimization and epoch-folding. Using an analysis of variance approach, I demonstrate the close relationship between these two methods. I also show that the significance test sometimes used in phase dispersion minimization is statistically inaccurate, and that the test used in epoch-folding is an approximation valid only for large sample sizes. I propose a new test statistic, applicable to either epoch-folding or PDM, which is statistically sound for all sample sizes, and which is also more sensitive to periodicity than the test statistics previously used with these two methods. (author)

  19. Distribution, variability, and predictors of urinary bisphenol A levels in 50 North Carolina adults over a six-week monitoring period.

    Science.gov (United States)

    Morgan, Marsha K; Nash, Maliha; Barr, Dana Boyd; Starr, James M; Scott Clifton, M; Sobus, Jon R

    2018-03-01

    Bisphenol A (BPA) is commonly manufactured to make polycarbonate plastics and epoxy resins for use in consumer products and packaged goods. BPA has been found in several different types of environmental media (e.g., food, dust, and air). Many cross-sectional studies have frequently detected BPA concentrations in adult urine samples. However, limited data are available on the temporal variability and important predictors of urinary BPA concentrations in adults. In this work, the major objectives were to: 1) quantify BPA levels in duplicate-diet solid food, drinking water, hard floor surface wipe, and urine samples (first-morning void [FMV], bedtime, and 24-h) collected from adults over a six-week monitoring period; 2) determine the temporal variability of urinary BPA levels using concentration, specific gravity (SG) adjusted, creatinine (CR) adjusted, and excretion rate values, and; 3) examine associations between available study factors and urinary BPA concentrations. In 2009-2011, a convenience sample of 50 adults was recruited from residential settings in North Carolina. The participants completed diaries and collected samples during weeks 1, 2, and/or 6 of a six-week monitoring period. BPA was detected in 38%, 4%, and 99% of the solid food (n=775), drinking water (n=50), and surface wipe samples (n=138), respectively. Total BPA (free plus conjugated) was detected in 98% of the 2477 urine samples. Median urinary BPA levels were 2.07ng/mL, 2.20ng/mL-SG, 2.29ng/mg, and 2.31ng/min for concentration, SG-adjusted, CR-adjusted, and excretion rate values, respectively. The intraclass correlation coefficient (ICC) estimates for BPA showed poor reproducibility (≤0.35) for all urine sample types and methods over a day, week, and six weeks. CR-adjusted bedtime voids collected over six-weeks required the fewest, realistic number of samples (n=11) to obtain a reliable biomarker estimate (ICC=0.80). Results of linear mixed-effects models showed that sex, race, season, and CR

  20. Small Body GN and C Research Report: G-SAMPLE - An In-Flight Dynamical Method for Identifying Sample Mass [External Release Version

    Science.gov (United States)

    Carson, John M., III; Bayard, David S.

    2006-01-01

    G-SAMPLE is an in-flight dynamical method for use by sample collection missions to identify the presence and quantity of collected sample material. The G-SAMPLE method implements a maximum-likelihood estimator to identify the collected sample mass, based on onboard force sensor measurements, thruster firings, and a dynamics model of the spacecraft. With G-SAMPLE, sample mass identification becomes a computation rather than an extra hardware requirement; the added cost of cameras or other sensors for sample mass detection is avoided. Realistic simulation examples are provided for a spacecraft configuration with a sample collection device mounted on the end of an extended boom. In one representative example, a 1000 gram sample mass is estimated to within 110 grams (95% confidence) under realistic assumptions of thruster profile error, spacecraft parameter uncertainty, and sensor noise. For convenience to future mission design, an overall sample-mass estimation error budget is developed to approximate the effect of model uncertainty, sensor noise, data rate, and thrust profile error on the expected estimate of collected sample mass.

  1. 40 CFR 141.703 - Sampling locations.

    Science.gov (United States)

    2010-07-01

    ... samples prior to the point of filter backwash water addition. (d) Bank filtration. (1) Systems that... applicable, must collect source water samples in the surface water prior to bank filtration. (2) Systems that use bank filtration as pretreatment to a filtration plant must collect source water samples from the...

  2. 77 FR 17493 - Agency Information Collection Activities: Proposed Collection; Comment Request; DOI Generic...

    Science.gov (United States)

    2012-03-26

    ... justify the proposed sample size, the expected response rate, methods for assessing potential non...: Proposed Collection; Comment Request; DOI Generic Clearance for the Collection of Qualitative Feedback on... (Generic ICR): ``DOI Generic Clearance for the Collection of Qualitative Feedback on Agency Service...

  3. 75 FR 80542 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2010-12-22

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  4. 76 FR 12140 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-03-04

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  5. 76 FR 17861 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-03-31

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  6. 76 FR 41280 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-07-13

    ... proposed sample size, the expected response rate, methods for assessing potential non-response bias, the... Activities: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...

  7. 76 FR 61360 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-10-04

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential... Activities: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative... Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under the Paperwork...

  8. Sedimentary characteristics of samples collected from some submarine canyons

    NARCIS (Netherlands)

    Bouma, Arnold H.

    Oriented rectangular cores of 20.3 × 30.5 cm and 45.7 cm high have been collected in a number of submarine canyons off southern California (U.S.A.) and off the southern tip of Baja California (Mexico) for a detailed study of their sedimentary structures. By applying several methods, mainly X-ray

  9. Stature in archeological samples from central Italy: methodological issues and diachronic changes.

    Science.gov (United States)

    Giannecchini, Monica; Moggi-Cecchi, Jacopo

    2008-03-01

    Stature reconstructions from skeletal remains are usually obtained through regression equations based on the relationship between height and limb bone length. Different equations have been employed to reconstruct stature in skeletal samples, but this is the first study to provide a systematic analysis of the reliability of the different methods for Italian historical samples. Aims of this article are: 1) to analyze the reliability of different regression methods to estimate stature for populations living in Central Italy from the Iron Age to Medieval times; 2) to search for trends in stature over this time period by applying the most reliable regression method. Long bone measurements were collected from 1,021 individuals (560 males, 461 females), from 66 archeological sites for males and 54 for females. Three time periods were identified: Iron Age, Roman period, and Medieval period. To determine the most appropriate equation to reconstruct stature the Delta parameter of Gini (Memorie di metodologia statistica. Milano: Giuffre A. 1939), in which stature estimates derived from different limb bones are compared, was employed. The equations proposed by Pearson (Philos Trans R Soc London 192 (1899) 169-244) and Trotter and Gleser for Afro-Americans (Am J Phys Anthropol 10 (1952) 463-514; Am J Phys Anthropol 47 (1977) 355-356) provided the most consistent estimates when applied to our sample. We then used the equation by Pearson for further analyses. Results indicate a reduction in stature in the transition from the Iron Age to the Roman period, and a subsequent increase in the transition from the Roman period to the Medieval period. Changes of limb lengths over time were more pronounced in the distal than in the proximal elements in both limbs. 2007 Wiley-Liss, Inc.

  10. Uranium isotopic signatures measured in samples of dirt collected at two former uranium facilities

    International Nuclear Information System (INIS)

    Meyers, L.A.; Stalcup, A.M.; LaMont, S.P.; Spitz, H.B.

    2014-01-01

    Nuclear forensics is a multidisciplinary science that uses a variety of analytical methods and tools to explore the physical, chemical, and isotopic characteristics of nuclear and radiological materials. These characteristics, when evaluated alone or in combination, become signatures that may reveal how and when the material was fabricated. The signatures contained in samples of dirt collected at two different uranium metal processing facilities in the United States were evaluated to determine uranium isotopic composition and compare results with processes that were conducted at these sites. One site refined uranium and fabricated uranium metal ingots for fuel and targets and the other site rolled hot forged uranium and other metals into dimensional rods. Unique signatures were found that are consistent with the activities and processes conducted at each facility and establish confidence in using these characteristics to reveal the provenance of other materials that exhibit similar signatures. (author)

  11. Stratospheric Air Sub-sampler (SAS) and its application to analysis of Delta O-17(CO2) from small air samples collected with an AirCore

    NARCIS (Netherlands)

    Mrozek, Dorota Janina; van der Veen, Carina; Hofmann, Magdalena E. G.; Chen, Huilin; Kivi, Rigel; Heikkinen, Pauli; Rockmann, Thomas

    2016-01-01

    We present the set-up and a scientific application of the Stratospheric Air Sub-sampler (SAS), a device to collect and to store the vertical profile of air collected with an AirCore (Karion et al., 2010) in numerous sub-samples for later analysis in the laboratory. The SAS described here is a 20m

  12. Isotopic change in the tissues of Bothrops atrox in captivity collected from environments of the eastern Amazon

    Science.gov (United States)

    Martinez, M. G.; Chalkidis, H. D.; Amazonas, D. R.; da Silva, A. M.; De Oliveira, R., Jr.; Camargo, P. B.

    2013-12-01

    The Bothrops atrox is little studied because it is sympatric Amazonian animals, and very little is known about the ecology and natural history of this species. It has a generalist diet and the distribution of this species is very wide. The adult animals forage mostly on the ground, while the younger animals prefer to stay on the vegetation. They are easily find in the rainy months in areas near lakes and seasonally flooded and are difficult to find in the driest months, a period where there is less availability of preys in these environments. Due to its aggressiveness, is considered one of the most feared snakes in South America and in the eastern Amazon, being responsible for the largest number of snakebites in the region. Through stable isotope carbon-13 and nitrogen-15, is intended to characterize the variations of the feeding habits of these collected animals in different environments and also when they are kept in captivity, feeding the animal's bioterium. The serpents were collected in environments with different land uses, such as native forest, savannah, pasture and have been brought to the serpentarium Integrated College Tapajos (FIT), being retained in order to Samplings throughout the experiment with feeding mice's own bioterium. When these snakes came from different locations, samples were collected scales and blood (T0), before receiving the new supply (captive), and every time we fed the mice the vivarium, new tissue samples were collected, (T1, T2, T3) to exchange all the nature of food for the food captivity.Based on the results of δ13C and δ15N, the samples collected in the tissues of snakes of different environments (nature and captivity), it was observed that changes in food sources reflect changes in tissues (blood and scales), also reflecting the production of poison different periods of turnover of absorbed material in those tissues, contributing to the study of animal ecology and behavior in relation to habitat.

  13. National Coral Reef Monitoring Program: Water Chemistry of the Coral Reefs in the Pacific Remote Island Areas from Water Samples collected since 2014

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Water samples are collected and analyzed to assess spatial and temporal variation in the seawater carbonate systems of coral reef ecosystems in the Hawaiian and...

  14. Variation in the diversity and richness of parasitoid wasps based on sampling effort.

    Science.gov (United States)

    Saunders, Thomas E; Ward, Darren F

    2018-01-01

    Parasitoid wasps are a mega-diverse, ecologically dominant, but poorly studied component of global biodiversity. In order to maximise the efficiency and reduce the cost of their collection, the application of optimal sampling techniques is necessary. Two sites in Auckland, New Zealand were sampled intensively to determine the relationship between sampling effort and observed species richness of parasitoid wasps from the family Ichneumonidae. Twenty traps were deployed at each site at three different times over the austral summer period, resulting in a total sampling effort of 840 Malaise-trap-days. Rarefaction techniques and non-parametric estimators were used to predict species richness and to evaluate the variation and completeness of sampling. Despite an intensive Malaise-trapping regime over the summer period, no asymptote of species richness was reached. At best, sampling captured two-thirds of parasitoid wasp species present. The estimated total number of species present depended on the month of sampling and the statistical estimator used. Consequently, the use of fewer traps would have caught only a small proportion of all species (one trap 7-21%; two traps 13-32%), and many traps contributed little to the overall number of individuals caught. However, variation in the catch of individual Malaise traps was not explained by seasonal turnover of species, vegetation or environmental conditions surrounding the trap, or distance of traps to one another. Overall the results demonstrate that even with an intense sampling effort the community is incompletely sampled. The use of only a few traps and/or for very short periods severely limits the estimates of richness because (i) fewer individuals are caught leading to a greater number of singletons; and (ii) the considerable variation of individual traps means some traps will contribute few or no individuals. Understanding how sampling effort affects the richness and diversity of parasitoid wasps is a useful

  15. Final Sampling and Analysis Plan for Background Sampling, Fort Sheridan, Illinois

    National Research Council Canada - National Science Library

    1995-01-01

    .... This Background Sampling and Analysis Plan (BSAP) is designed to address this issue through the collection of additional background samples at Fort Sheridan to support the statistical analysis and the Baseline Risk Assessment (BRA...

  16. Wilsonville wastewater sampling program. Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1983-10-01

    As part of its contrast to design, build and operate the SRC-1 Demonstration Plant in cooperation with the US Department of Energy (DOE), International Coal Refining Company (ICRC) was required to collect and evaluate data related to wastewater streams and wastewater treatment procedures at the SRC-1 Pilot Plant facility. The pilot plant is located at Wilsonville, Alabama and is operated by Catalytic, Inc. under the direction of Southern Company Services. The plant is funded in part by the Electric Power Research Institute and the DOE. ICRC contracted with Catalytic, Inc. to conduct wastewater sampling. Tasks 1 through 5 included sampling and analysis of various wastewater sources and points of different steps in the biological treatment facility at the plant. The sampling program ran from May 1 to July 31, 1982. Also included in the sampling program was the generation and analysis of leachate from SRC product using standard laboratory leaching procedures. For Task 6, available plant wastewater data covering the period from February 1978 to December 1981 was analyzed to gain information that might be useful for a demonstration plant design basis. This report contains a tabulation of the analytical data, a summary tabulation of the historical operating data that was evaluated and comments concerning the data. The procedures used during the sampling program are also documented.

  17. 76 FR 63301 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-10-12

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under...

  18. Extensive monitoring through multiple blood samples in professional soccer players

    DEFF Research Database (Denmark)

    Heisterberg, Mette F; Fahrenkrug, Jan; Krustrup, Peter

    2013-01-01

    of the season. Leucocytes decreased with increased physical training. Lymphocytes decreased at the end of the season. VO2max decreased towards the end of the season whereas no significant changes were observed in the IE2 test.The regular blood samples from elite soccer players reveal significant changes......ABSTRACT: The aim of this study was to make a comprehensive gathering of consecutive detailed blood samples from professional soccer players, and to analyze different blood parameters in relation to seasonal changes in training and match exposure.Blood samples were collected five times during a six...... months period and analyzed for 37 variables in 27 professional soccer players from the best Danish league. Additionally, players were tested for body composition, VO2max and physical performance by the Yo-Yo intermittent endurance sub-max test (IE2).Multiple variations in blood parameters occurred during...

  19. The vanishing Black Indian: Revisiting craniometry and historic collections.

    Science.gov (United States)

    Geller, Pamela L; Stojanowksi, Christopher M

    2017-02-01

    This article uses craniometric allocation as a platform for discussing the legacy of Samuel G. Morton's collection of crania, the process of racialization, and the value of contextualized biohistoric research perspectives in biological anthropology. Standard craniometric measurements were recorded for seven Seminoles in the Samuel G. Morton Crania Collection and 10 European soldiers from the Fort St. Marks Military Cemetery; all individuals were men and died in Florida during the 19th century. Fordisc 3.1 was used to assess craniometric affinity with respect to three samples: the Forensic Data Bank, Howells data set, and an archival sample that best fits the target populations collected from 19th century Florida. Discriminant function analyses were used to evaluate how allocations change across the three comparative databases, which roughly reflect a temporal sequence. Most Seminoles allocated as Native American, while most soldiers allocated as Euro-American. Allocation of Seminole crania, however, was unstable across analysis runs with more individuals identifying as African Americans when compared to the Howells and Forensic Data Bank. To the contrary, most of the soldiers produced consistent allocations across analyses. Repeatability for the St. Marks sample was lower when using the archival sample database, contrary to expectations. For the Seminole crania, Cohen's κ indicates significantly lower repeatability. A possible Black Seminole individual was identified in the Morton Collection. Recent articles discussing the merits and weaknesses of comparative craniometry focus on methodological issues. In our biohistoric approach, we use the patterning of craniometric allocations across databases as a platform for discussing social race and its development during the 19th century, a process known as racialization. Here we propose that differences in repeatability for the Seminoles and Euro-American soldiers reflect this process and transformation of racialized

  20. Collective estimation of multiple bivariate density functions with application to angular-sampling-based protein loop modeling

    KAUST Repository

    Maadooliat, Mehdi

    2015-10-21

    This paper develops a method for simultaneous estimation of density functions for a collection of populations of protein backbone angle pairs using a data-driven, shared basis that is constructed by bivariate spline functions defined on a triangulation of the bivariate domain. The circular nature of angular data is taken into account by imposing appropriate smoothness constraints across boundaries of the triangles. Maximum penalized likelihood is used to fit the model and an alternating blockwise Newton-type algorithm is developed for computation. A simulation study shows that the collective estimation approach is statistically more efficient than estimating the densities individually. The proposed method was used to estimate neighbor-dependent distributions of protein backbone dihedral angles (i.e., Ramachandran distributions). The estimated distributions were applied to protein loop modeling, one of the most challenging open problems in protein structure prediction, by feeding them into an angular-sampling-based loop structure prediction framework. Our estimated distributions compared favorably to the Ramachandran distributions estimated by fitting a hierarchical Dirichlet process model; and in particular, our distributions showed significant improvements on the hard cases where existing methods do not work well.