WorldWideScience

Sample records for sample collection method

  1. Fast egg collection method greatly improves randomness of egg sampling in Drosophila melanogaster

    DEFF Research Database (Denmark)

    Schou, Mads Fristrup

    2013-01-01

    When obtaining samples for population genetic studies, it is essential that the sampling is random. For Drosophila, one of the crucial steps in sampling experimental flies is the collection of eggs. Here an egg collection method is presented, which randomizes the eggs in a water column...... and diminishes environmental variance. This method was compared with a traditional egg collection method where eggs are collected directly from the medium. Within each method the observed and expected standard deviations of egg-to-adult viability were compared, whereby the difference in the randomness...... and to obtain a representative collection of genotypes, the method presented here is strongly recommended when collecting eggs from Drosophila....

  2. IMPROVEMENT OF METHODS FOR HYDROBIOLOGICAL RESEARCH AND MODIFICATION OF STANDARD TOOLS FOR SAMPLE COLLECTION

    Directory of Open Access Journals (Sweden)

    M. M. Aligadjiev

    2015-01-01

    Full Text Available Aim. The paper discusses the improvement of methods of hydrobiological studies by modifying tools for plankton and benthic samples collecting. Methods. In order to improve the standard methods of hydro-biological research, we have developed tools for sampling zooplankton and benthic environment of the Caspian Sea. Results. Long-term practice of selecting hydrobiological samples in the Caspian Sea shows that it is required to complete the modernization of the sampling tools used to collect hydrobiological material. With the introduction of Azov and Black Sea invasive comb jelly named Mnemiopsis leidyi A. Agassiz to the Caspian Sea there is a need to collect plankton samples without disturbing its integrity. Tools for collecting benthic fauna do not always give a complete picture of the state of benthic ecosystems because of the lack of visual site selection for sampling. Moreover, while sampling by dredge there is a probable loss of the samples, especially in areas with difficult terrain. Conclusion. We propose to modify a small model of Upstein net (applied in shallow water to collect zooplankton samples with an upper inverted cone that will significantly improve the catchability of the net in theCaspian Sea. Bottom sampler can be improved by installing a video camera for visual inspection of the bottom topography, and use sensors to determine tilt of the dredge and the position of the valves of the bucket. 

  3. Methods for collecting algal samples as part of the National Water-Quality Assessment Program

    Science.gov (United States)

    Porter, Stephen D.; Cuffney, Thomas F.; Gurtz, Martin E.; Meador, Michael R.

    1993-01-01

    Benthic algae (periphyton) and phytoplankton communities are characterized in the U.S. Geological Survey's National Water-Quality Assessment Program as part of an integrated physical, chemical, and biological assessment of the Nation's water quality. This multidisciplinary approach provides multiple lines of evidence for evaluating water-quality status and trends, and for refining an understanding of the factors that affect water-quality conditions locally, regionally, and nationally. Water quality can be characterized by evaluating the results of qualitative and quantitative measurements of the algal community. Qualitative periphyton samples are collected to develop of list of taxa present in the sampling reach. Quantitative periphyton samples are collected to measure algal community structure within selected habitats. These samples of benthic algal communities are collected from natural substrates, using the sampling methods that are most appropriate for the habitat conditions. Phytoplankton samples may be collected in large nonwadeable streams and rivers to meet specific program objectives. Estimates of algal biomass (chlorophyll content and ash-free dry mass) also are optional measures that may be useful for interpreting water-quality conditions. A nationally consistent approach provides guidance on site, reach, and habitat selection, as well as information on methods and equipment for qualitative and quantitative sampling. Appropriate quality-assurance and quality-control guidelines are used to maximize the ability to analyze data locally, regionally, and nationally.

  4. Assembly for collecting samples for purposes of identification or analysis and method of use

    Science.gov (United States)

    Thompson, Cyril V [Knoxville, TN; Smith, Rob R [Knoxville, TN

    2010-02-02

    An assembly and an associated method for collecting a sample of material desired to be characterized with diagnostic equipment includes or utilizes an elongated member having a proximal end with which the assembly is manipulated by a user and a distal end. In addition, a collection tip which is capable of being placed into contact with the material to be characterized is supported upon the distal end. The collection tip includes a body of chemically-inert porous material for binding a sample of material when the tip is placed into contact with the material and thereby holds the sample of material for subsequent introduction to the diagnostic equipment.

  5. Evaluation of standard methods for collecting and processing fuel moisture samples

    Science.gov (United States)

    Sally M. Haase; José Sánchez; David R. Weise

    2016-01-01

    A variety of techniques for collecting and processing samples to determine moisture content of wildland fuels in support of fire management activities were evaluated. The effects of using a chainsaw or handsaw to collect samples of largediameter wood, containers for storing and transporting collected samples, and quick-response ovens for estimating moisture content...

  6. 222Rn in water: A comparison of two sample collection methods and two sample transport methods, and the determination of temporal variation in North Carolina ground water

    International Nuclear Information System (INIS)

    Hightower, J.H. III

    1994-01-01

    Objectives of this field experiment were: (1) determine whether there was a statistically significant difference between the radon concentrations of samples collected by EPA's standard method, using a syringe, and an alternative, slow-flow method; (2) determine whether there was a statistically significant difference between the measured radon concentrations of samples mailed vs samples not mailed; and (3) determine whether there was a temporal variation of water radon concentration over a 7-month period. The field experiment was conducted at 9 sites, 5 private wells, and 4 public wells, at various locations in North Carolina. Results showed that a syringe is not necessary for sample collection, there was generally no significant radon loss due to mailing samples, and there was statistically significant evidence of temporal variations in water radon concentrations

  7. Methods for the collection of subsurface samples during environmental site assessments

    International Nuclear Information System (INIS)

    Weinstock, E.A.

    1996-01-01

    This paper discusses numerous sample collection techniques that have been successfully employed during Phase 2 Assessments and presents case histories of their application. Pollutants of concern include PCE and petroleum. The collection of shallow soil samples is described using commercially available hand augers and hand-driven core samplers. These devices are modified with extensions to collect deeper samples from storm drains and leaching pools. The performance of soil gas surveys are described using both hand-driven sample probes and vehicle-mounted, hydraulically driven vapor probes. Once the soil vapor is collected at the ground surface, a sample of the media is either analyzed on-site using a field-operated detection device or delivered to a laboratory for analysis. Application and case histories of the Geoprobe(trademark)sampling system, a form of direct push technology, are described. This device uses vehicle-mounted, hydraulically-driven sample probes. The probe can be advanced to depths as great as 100 feet below grade and can retrieve soil, soil gas and groundwater samples

  8. Acceptability of self-collection sampling for HPV-DNA testing in low-resource settings: a mixed methods approach.

    Science.gov (United States)

    Bansil, Pooja; Wittet, Scott; Lim, Jeanette L; Winkler, Jennifer L; Paul, Proma; Jeronimo, Jose

    2014-06-12

    Vaginal self-sampling with HPV-DNA tests is a promising primary screening method for cervical cancer. However, women's experiences, concerns and the acceptability of such tests in low-resource settings remain unknown. In India, Nicaragua, and Uganda, a mixed-method design was used to collect data from surveys (N = 3,863), qualitative interviews (N = 72; 20 providers and 52 women) and focus groups (N = 30 women) on women's and providers' experiences with self-sampling, women's opinions of sampling at home, and their future needs. Among surveyed women, 90% provided a self- collected sample. Of these, 75% reported it was easy, although 52% were initially concerned about hurting themselves and 24% were worried about not getting a good sample. Most surveyed women preferred self-sampling (78%). However it was not clear if they responded to the privacy of self-sampling or the convenience of avoiding a pelvic examination, or both. In follow-up interviews, most women reported that they didn't mind self-sampling, but many preferred to have a provider collect the vaginal sample. Most women also preferred clinic-based screening (as opposed to home-based self-sampling), because the sample could be collected by a provider, women could receive treatment if needed, and the clinic was sanitary and provided privacy. Self-sampling acceptability was higher when providers prepared women through education, allowed women to examine the collection brush, and were present during the self-collection process. Among survey respondents, aids that would facilitate self-sampling in the future were: staff help (53%), additional images in the illustrated instructions (31%), and a chance to practice beforehand with a doll/model (26%). Self-and vaginal-sampling are widely acceptable among women in low-resource settings. Providers have a unique opportunity to educate and prepare women for self-sampling and be flexible in accommodating women's preference for self-sampling.

  9. Method for rapid screening analysis of Sr-90 in edible plant samples collected near Fukushima, Japan

    International Nuclear Information System (INIS)

    Amano, Hikaru; Sakamoto, Hideaki; Shiga, Norikatsu; Suzuki, Kaori

    2016-01-01

    A screening method for measuring 90 Sr in edible plant samples by focusing on 90 Y in equilibrium with 90 Sr is reported. 90 Y was extracted from samples with acid, co-precipitated with iron hydroxide, and precipitated with oxalic acid. The dissolved oxalate precipitate was loaded on an extraction chromatography resin, and the 90 Y-enriched eluate was analyzed by Cherenkov counting with a TDCR liquid scintillation counter. 90 Sr ( 90 Y) concentration was determined in plant samples collected near the damaged Fukushima Daiichi Nuclear Power Plants with this method. - Highlights: • A screening method for measuring 90 Sr in edible plant samples by focusing on 90 Y in equilibrium with 90 Sr is reported. • 90 Y was extracted from samples with acid, co-precipitated with iron hydroxide, and precipitated with oxalic acid. • The dissolved oxalate precipitate was loaded on an extraction chromatography resin. • 90 Y-enriched eluate was analyzed by Cherenkov counting with a TDCR liquid scintillation counter. • 90 Sr ( 90 Y) concentration was determined in edible plant samples collected near the damaged Fukushima Daiichi NPPs with this method.

  10. Standardized Method for Measuring Collection Efficiency from Wipe-sampling of Trace Explosives.

    Science.gov (United States)

    Verkouteren, Jennifer R; Lawrence, Jeffrey A; Staymates, Matthew E; Sisco, Edward

    2017-04-10

    One of the limiting steps to detecting traces of explosives at screening venues is effective collection of the sample. Wipe-sampling is the most common procedure for collecting traces of explosives, and standardized measurements of collection efficiency are needed to evaluate and optimize sampling protocols. The approach described here is designed to provide this measurement infrastructure, and controls most of the factors known to be relevant to wipe-sampling. Three critical factors (the applied force, travel distance, and travel speed) are controlled using an automated device. Test surfaces are chosen based on similarity to the screening environment, and the wipes can be made from any material considered for use in wipe-sampling. Particle samples of the explosive 1,3,5-trinitroperhydro-1,3,5-triazine (RDX) are applied in a fixed location on the surface using a dry-transfer technique. The particle samples, recently developed to simulate residues made after handling explosives, are produced by inkjet printing of RDX solutions onto polytetrafluoroethylene (PTFE) substrates. Collection efficiency is measured by extracting collected explosive from the wipe, and then related to critical sampling factors and the selection of wipe material and test surface. These measurements are meant to guide the development of sampling protocols at screening venues, where speed and throughput are primary considerations.

  11. Use of aspiration method for collecting brain samples for rabies diagnosis in small wild animals.

    Science.gov (United States)

    Iamamoto, K; Quadros, J; Queiroz, L H

    2011-02-01

    In developing countries such as Brazil, where canine rabies is still a considerable problem, samples from wildlife species are infrequently collected and submitted for screening for rabies. A collaborative study was established involving environmental biologists and veterinarians for rabies epidemiological research in a specific ecological area located at the Sao Paulo State, Brazil. The wild animals' brains are required to be collected without skull damage because the skull's measurements are important in the identification of the captured animal species. For this purpose, samples from bats and small mammals were collected using an aspiration method by inserting a plastic pipette into the brain through the magnum foramen. While there is a progressive increase in the use of the plastic pipette technique in various studies undertaken, it is also appreciated that this method could foster collaborative research between wildlife scientists and rabies epidemiologists thus improving rabies surveillance. © 2009 Blackwell Verlag GmbH.

  12. A simple and novel method for retrieval of Pasteurellaceae from swab samples collected in the field

    DEFF Research Database (Denmark)

    Hansen, Mie J; Bertelsen, Mads F; Dietz, Rune

    2013-01-01

    and stored at -20°C. As a control study, 15 samples were collected from the oral cavity of a captive brown bear. One was immediately plated, while the remaining 12 swabs were stored at -20°C for 7 days and multiples of 30 days up to 330 days prior to plating. Two samples were stored without the medium for 7......Traditionally it has been difficult or impossible to collect and preserve bacterial samples of especially fastidious bacteria in mixed primary cultures, unless the samples could be transported to a laboratory within approximately 24 h. Therefore, a simple novel method for preserving swab samples...... until bacterial isolation can be completed in the laboratory was developed and evaluated. Pasteurellaceae bacteria were used as a representative for fastidious bacteria. A 7.5% glucose serum medium was used as freeze medium. Swab samples were soaked in the medium a maximum of 2 h after collection...

  13. Collection and preparation of samples for gamma spectrometry

    International Nuclear Information System (INIS)

    Pan Jingquan

    1994-01-01

    The paper presents the basic principles of sample collection and preparation: setting up unified sampling program, methods and procedures, sample packing, transportation and storage, determination of sample quantity, sample pretreatment and preparation of samples to be analysed, etc. for gamma spectrometry. And the paper also describes briefly the main methods and special issues of sampling and preparation for the same environmental and biological samples, such as, air, water, grass, soil and foods

  14. Demonstration Exercise of a Validated Sample Collection Method for Powders Suspected of Being Biological Agents in Georgia 2006

    International Nuclear Information System (INIS)

    Marsh, B.

    2007-01-01

    August 7, 2006 the state of Georgia conducted a collaborative sampling exercise between the Georgia National Guard 4th Civil Support Team Weapons of Mass Destruction (CST-WMD) and the Georgia Department of Human Resources Division of Public Health demonstrating a recently validated bulk powder sampling method. The exercise was hosted at the Federal Law Enforcement Training Center (FLETC) at Glynn County, Georgia and involved the participation of the Georgia Emergency Management Agency (GEMA), Georgia National Guard, Georgia Public Health Laboratories, the Federal Bureau of Investigation Atlanta Office, Georgia Coastal Health District, and the Glynn County Fire Department. The purpose of the exercise was to demonstrate a recently validated national sampling standard developed by the American Standards and Test Measures (ASTM) International; ASTM E2458 S tandard Practice for Bulk Sample Collection and Swab Sample Collection of Visible Powders Suspected of Being Biological Agents from Nonporous Surfaces . The intent of the exercise was not to endorse the sampling method, but to develop a model for exercising new sampling methods in the context of existing standard operating procedures (SOPs) while strengthening operational relationships between response teams and analytical laboratories. The exercise required a sampling team to respond real-time to an incident cross state involving a clandestine bio-terrorism production lab found within a recreational vehicle (RV). Sample targets consisted of non-viable gamma irradiated B. anthracis Sterne spores prepared by Dugway Proving Ground. Various spore concentration levels were collected by the ASTM method, followed by on- and off-scene analysis utilizing the Center for Disease Control (CDC) Laboratory Response Network (LRN) and National Guard Bureau (NGB) CST mobile Analytical Laboratory Suite (ALS) protocols. Analytical results were compared and detailed surveys of participant evaluation comments were examined. I will

  15. Biopolymers for sample collection, protection, and preservation.

    Science.gov (United States)

    Sorokulova, Iryna; Olsen, Eric; Vodyanoy, Vitaly

    2015-07-01

    One of the principal challenges in the collection of biological samples from air, water, and soil matrices is that the target agents are not stable enough to be transferred from the collection point to the laboratory of choice without experiencing significant degradation and loss of viability. At present, there is no method to transport biological samples over considerable distances safely, efficiently, and cost-effectively without the use of ice or refrigeration. Current techniques of protection and preservation of biological materials have serious drawbacks. Many known techniques of preservation cause structural damages, so that biological materials lose their structural integrity and viability. We review applications of a novel bacterial preservation process, which is nontoxic and water soluble and allows for the storage of samples without refrigeration. The method is capable of protecting the biological sample from the effects of environment for extended periods of time and then allows for the easy release of these collected biological materials from the protective medium without structural or DNA damage. Strategies for sample collection, preservation, and shipment of bacterial, viral samples are described. The water-soluble polymer is used to immobilize the biological material by replacing the water molecules within the sample with molecules of the biopolymer. The cured polymer results in a solid protective film that is stable to many organic solvents, but quickly removed by the application of the water-based solution. The process of immobilization does not require the use of any additives, accelerators, or plastifiers and does not involve high temperature or radiation to promote polymerization.

  16. Concentration comparison of selected constituents between groundwater samples collected within the Missouri River alluvial aquifer using purge and pump and grab-sampling methods, near the city of Independence, Missouri, 2013

    Science.gov (United States)

    Krempa, Heather M.

    2015-10-29

    The U.S. Geological Survey, in cooperation with the City of Independence, Missouri, Water Department, has historically collected water-quality samples using the purge and pump method (hereafter referred to as pump method) to identify potential contamination in groundwater supply wells within the Independence well field. If grab sample results are comparable to the pump method, grab samplers may reduce time, labor, and overall cost. This study was designed to compare constituent concentrations between samples collected within the Independence well field using the pump method and the grab method.

  17. Assessing human error during collecting a hydrocarbon sample of ...

    African Journals Online (AJOL)

    This paper reports the assessment method of the hydrocarbon sample collection standard operation procedure (SOP) using THERP. The Performance Shaping Factors (PSF) from THERP analyzed and assessed the human errors during collecting a hydrocarbon sample of a petrochemical refinery plant. Twenty-two ...

  18. Sample collection and documentation

    International Nuclear Information System (INIS)

    Cullings, Harry M.; Fujita, Shoichiro; Watanabe, Tadaaki; Yamashita, Tomoaki; Tanaka, Kenichi; Endo, Satoru; Shizuma, Kiyoshi; Hoshi, Masaharu; Hasai, Hiromi

    2005-01-01

    Beginning within a few weeks after the bombings and periodically during the intervening decades, investigators in Hiroshima and Nagasaki have collected samples of materials that were in the cities at the time of the bombings. Although some early efforts were not driven by specific measurement objectives, many others were. Even some of the very earliest samples collected in 1945 were based on carefully conceived research plans and detailed specifications for samples appropriate to particular retrospective measurements, i.e., of particular residual quantities remaining from exposure to the neutrons and gamma rays from the bombs. This chapter focuses mainly on the work of groups at two institutions that have actively collaborated since the 1980s in major collection efforts and have shared samples among themselves and with other investigators: the Radiation Effects Research Foundation (RERF) and its predecessor the Atomic Bomb Casualty Commission (ABCC), and Hiroshima University. In addition, a number of others are listed, who also contributed to the literature by their collection of samples. (J.P.N.)

  19. Repeatability of oral fluid collection methods for THC measurement

    NARCIS (Netherlands)

    Houwing, Sjoerd; Smink, Beitske E.; Legrand, Sara-Ann; Mathijssen, Rene P. M.; Verstraete, Alain G.; Brookhuis, Karel A.

    2012-01-01

    Study objectives: To determine the influence of sample collection for two different collection methods on THC concentrations and to compare THC concentrations collected by both methods. Methods: A total of 136 pairs of oral fluid samples from subjects who had recently smoked Cannabis were obtained

  20. Soil sample collection and analysis for the Fugitive Dust Characterization Study

    Science.gov (United States)

    Ashbaugh, Lowell L.; Carvacho, Omar F.; Brown, Michael S.; Chow, Judith C.; Watson, John G.; Magliano, Karen C.

    A unique set of soil samples was collected as part of the Fugitive Dust Characterization Study. The study was carried out to establish whether or not source profiles could be constructed using novel analytical methods that could distinguish soil dust sources from each other. The soil sources sampled included fields planted in cotton, almond, tomato, grape, and safflower, dairy and feedlot facilities, paved and unpaved roads (both urban and rural), an agricultural staging area, disturbed land with salt buildup, and construction areas where the topsoil had been removed. The samples were collected using a systematic procedure designed to reduce sampling bias, and were stored frozen to preserve possible organic signatures. For this paper the samples were characterized by particle size (percent sand, silt, and clay), dry silt content (used in EPA-recommended fugitive dust emission factors), carbon and nitrogen content, and potential to emit both PM 10 and PM 2.5. These are not the "novel analytical methods" referred to above; rather, it was the basic characterization of the samples to use in comparing analytical methods by other scientists contracted to the California Air Resources Board. The purpose of this paper is to document the methods used to collect the samples, the collection locations, the analysis of soil type and potential to emit PM 10, and the sample variability, both within field and between fields of the same crop type.

  1. Repeatability of oral fluid collection methods for THC measurement.

    NARCIS (Netherlands)

    Houwing, S. Smink, B.E. Legrand, S.-A. Mathijssen, M.P.M. Verstraete, A.G. & Brookhuis, K.A.

    2013-01-01

    The study objective was to determine the influence of sample collection for two different collection methods on THC concentrations and to compare THC concentrations collected by both methods. A total of 136 pairs of oral fluid samples from subjects who had recently smoked Cannabis were obtained by

  2. Assessment of high-risk human papillomavirus infections using clinician- and self-collected cervical sampling methods in rural women from far western Nepal.

    Directory of Open Access Journals (Sweden)

    Derek C Johnson

    Full Text Available Nepal has one of the highest cervical cancer rates in South Asia. Only a few studies in populations from urban areas have investigated type specific distribution of human papillomavirus (HPV in Nepali women. Data on high-risk HPV (HR-HPV types are not currently available for rural populations in Nepal. We aimed to assess the distribution of HR- HPV among rural Nepali women while assessing self-collected and clinician-collected cervico-vaginal specimens as sample collection methods for HPV screening.Study participants were recruited during a health camp conducted by Nepal Fertility Care Center in Achham District of rural far western Nepal. Women of reproductive age completed a socio-demographic and clinical questionnaire, and provided two specimens; one cervical-vaginal specimen using a self-collection method and another cervical specimen collected by health camp auxiliary nurse midwives during a pelvic examination. All samples were tested for 14 different HR-HPV mRNA and also specific for HPV16/18/45 mRNA.Of 261 women with both clinician- and self-collected cervical samples, 25 tested positive for HR-HPV, resulting in an overall HR-HPV prevalence of 9.6% (95% confidence Interval [CI]: 6.3-13.8. The overall Kappa value assessing agreement between clinician- and self-collected tests was 0.62 (95% CI: 0.43-0.81, indicating a "good" level of agreement. Abnormal cytology was reported for 8 women. One woman identified with squamous cell carcinoma (SCC, and 7 women with high grade squamous intraepithelial lesions (HSIL. Seven of the 8 women tested positive for HR-HPV (87.5% in clinician-collected samples and 6 in self-collected samples (75.0%.This is the first study to assess HR-HPV among rural Nepali women. Self-collected sampling methods should be the subject of additional research in Nepal for screening HR-HPV, associated with pre-cancer lesions and cancer, in women in rural areas with limited access to health services.

  3. Organic analysis of ambient samples collected near Tank 241-C-103: Results from samples collected on May 12, 1994

    International Nuclear Information System (INIS)

    Clauss, T.W.; Ligotke, M.W.; McVeety, B.D.; Lucke, R.B.; Young, J.S.; McCulloch, M.; Fruchter, J.S.; Goheen, S.C.

    1995-06-01

    This report describes organic analyses results from ambient samples collected both upwind and through the vapor sampling system (VSS) near Hanford waste storage Tank 241-C-103 (referred to as Tank C-103). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed. Quantitative results were obtained for organic compounds. Five organic tentatively identified compounds (TICS) were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and the reported concentrations are semiquantitative estimates. In addition, we looked for the 40 standard TO-14 analytes. We observed 39. Of these, only one was observed above the 2-ppbv calibrated instrument detection limit. Dichloromethane was above the detection limits using both methods, but the result from the TO-14 method is traceable to a standard gas mixture and is considered more accurate. Organic analytes were found only in the sample collected through the VSS, suggesting that these compounds were residual contamination from a previous sampling job. Detailed descriptions of the results appear in the text

  4. Protocol for collecting eDNA samples from streams [Version 2.3

    Science.gov (United States)

    K. J. Carim; T. Wilcox; M. K. Young; K. S. McKelvey; M. K. Schwartz

    2015-01-01

    Throughout the 2014 field season, we had over two dozen biologist throughout the western US collect over 300 samples for eDNA analysis with paired controls. Control samples were collected by filtering 0.5 L of distilled water. No samples had any evidence of field contamination. This method of sampling verifies the cleanliness of the field equipment, as well as the...

  5. Macroinvertebrate and algal community sample collection methods and data collected at selected sites in the Eagle River watershed, Colorado, 2000-07

    Science.gov (United States)

    Zuellig, Robert E.; Bruce, James F.

    2010-01-01

    State and local agencies are concerned about the effects of increasing urban development and human population growth on water quality and the biological condition of regional streams in the Eagle River watershed. In response to these needs, the U.S. Geological Survey initiated a study in cooperation with the Colorado River Water Conservation District, Eagle County, Eagle River Water and Sanitation District, Upper Eagle Regional Water Authority, Colorado Department of Transportation, City of Aurora, Town of Eagle, Town of Gypsum, Town of Minturn, Town of Vail, Vail Resorts, Colorado Springs Utilities, Denver Water, and the U.S. Department of Agriculture Forest Service. As part of this study, previously collected macroinvertebrate and algal data from the Eagle River watershed were compiled. This report includes macroinvertebrate data collected by the U.S. Geological Survey and(or) the U.S. Department of Agriculture Forest Service from 73 sites from 2000 to 2007 and algal data collected from up to 26 sites between 2000 and 2001 in the Eagle River watershed. Additionally, a brief description of the sample collection methods and data processing procedures are presented.

  6. Some connections between importance sampling and enhanced sampling methods in molecular dynamics.

    Science.gov (United States)

    Lie, H C; Quer, J

    2017-11-21

    In molecular dynamics, enhanced sampling methods enable the collection of better statistics of rare events from a reference or target distribution. We show that a large class of these methods is based on the idea of importance sampling from mathematical statistics. We illustrate this connection by comparing the Hartmann-Schütte method for rare event simulation (J. Stat. Mech. Theor. Exp. 2012, P11004) and the Valsson-Parrinello method of variationally enhanced sampling [Phys. Rev. Lett. 113, 090601 (2014)]. We use this connection in order to discuss how recent results from the Monte Carlo methods literature can guide the development of enhanced sampling methods.

  7. Characteristics of HIV target CD4 T cells collected using different sampling methods from the genital tract of HIV seronegative women.

    Science.gov (United States)

    Iyer, Smita S; Sabula, Michael J; Mehta, C Christina; Haddad, Lisa B; Brown, Nakita L; Amara, Rama R; Ofotokun, Igho; Sheth, Anandi N

    2017-01-01

    Understanding the immune profile of CD4 T cells, the primary targets for HIV, in the female genital tract (FGT) is critical for evaluating and developing effective biomedical HIV prevention strategies in women. However, longitudinal investigation of HIV susceptibility markers expressed by FGT CD4 T cells has been hindered by low cellular yield and risk of sampling-associated trauma. We investigated three minimally invasive FGT sampling methods to characterize and compare CD4 T cell yield and phenotype with the goal of establishing feasible sampling strategies for immune profiling of mucosal CD4 T cells. FGT samples were collected bimonthly from 12 healthy HIV negative women of reproductive age in the following order: 1) Cervicovaginal lavage (CVL), 2) two sequential endocervical flocked swabs (FS), and 3) two sequential endocervical cytobrushes (CB1, CB2). Cells were isolated and phentoyped via flow cytometry. CD4 T cell recovery was highest from each individual CB compared to either CVL or FS (p sampling method, expressed CCR5 relative to peripheral blood (p samples. Using three different mucosal sampling methods collected longitudinally we demonstrate that CD4 T cells within the FGT express CCR5 and α4β7 and are highly activated, attributes which could act in concert to facilitate HIV acquisition. FS and CB sampling methods can allow for investigation of strategies to reduce HIV target cells in the FGT and could inform the design and interpretation microbicide and vaccine studies in women.

  8. Independent random sampling methods

    CERN Document Server

    Martino, Luca; Míguez, Joaquín

    2018-01-01

    This book systematically addresses the design and analysis of efficient techniques for independent random sampling. Both general-purpose approaches, which can be used to generate samples from arbitrary probability distributions, and tailored techniques, designed to efficiently address common real-world practical problems, are introduced and discussed in detail. In turn, the monograph presents fundamental results and methodologies in the field, elaborating and developing them into the latest techniques. The theory and methods are illustrated with a varied collection of examples, which are discussed in detail in the text and supplemented with ready-to-run computer code. The main problem addressed in the book is how to generate independent random samples from an arbitrary probability distribution with the weakest possible constraints or assumptions in a form suitable for practical implementation. The authors review the fundamental results and methods in the field, address the latest methods, and emphasize the li...

  9. Sampling methods

    International Nuclear Information System (INIS)

    Loughran, R.J.; Wallbrink, P.J.; Walling, D.E.; Appleby, P.G.

    2002-01-01

    Methods for the collection of soil samples to determine levels of 137 Cs and other fallout radionuclides, such as excess 210 Pb and 7 Be, will depend on the purposes (aims) of the project, site and soil characteristics, analytical capacity, the total number of samples that can be analysed and the sample mass required. The latter two will depend partly on detector type and capabilities. A variety of field methods have been developed for different field conditions and circumstances over the past twenty years, many of them inherited or adapted from soil science and sedimentology. The use of them inherited or adapted from soil science and sedimentology. The use of 137 Cs in erosion studies has been widely developed, while the application of fallout 210 Pb and 7 Be is still developing. Although it is possible to measure these nuclides simultaneously, it is common for experiments to designed around the use of 137 Cs along. Caesium studies typically involve comparison of the inventories found at eroded or sedimentation sites with that of a 'reference' site. An accurate characterization of the depth distribution of these fallout nuclides is often required in order to apply and/or calibrate the conversion models. However, depending on the tracer involved, the depth distribution, and thus the sampling resolution required to define it, differs. For example, a depth resolution of 1 cm is often adequate when using 137 Cs. However, fallout 210 Pb and 7 Be commonly has very strong surface maxima that decrease exponentially with depth, and fine depth increments are required at or close to the soil surface. Consequently, different depth incremental sampling methods are required when using different fallout radionuclides. Geomorphic investigations also frequently require determination of the depth-distribution of fallout nuclides on slopes and depositional sites as well as their total inventories

  10. Experimental and Sampling Design for the INL-2 Sample Collection Operational Test

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Amidan, Brett G.; Matzke, Brett D.

    2009-02-16

    This report describes the experimental and sampling design developed to assess sampling approaches and methods for detecting contamination in a building and clearing the building for use after decontamination. An Idaho National Laboratory (INL) building will be contaminated with BG (Bacillus globigii, renamed Bacillus atrophaeus), a simulant for Bacillus anthracis (BA). The contamination, sampling, decontamination, and re-sampling will occur per the experimental and sampling design. This INL-2 Sample Collection Operational Test is being planned by the Validated Sampling Plan Working Group (VSPWG). The primary objectives are: 1) Evaluate judgmental and probabilistic sampling for characterization as well as probabilistic and combined (judgment and probabilistic) sampling approaches for clearance, 2) Conduct these evaluations for gradient contamination (from low or moderate down to absent or undetectable) for different initial concentrations of the contaminant, 3) Explore judgment composite sampling approaches to reduce sample numbers, 4) Collect baseline data to serve as an indication of the actual levels of contamination in the tests. A combined judgmental and random (CJR) approach uses Bayesian methodology to combine judgmental and probabilistic samples to make clearance statements of the form "X% confidence that at least Y% of an area does not contain detectable contamination” (X%/Y% clearance statements). The INL-2 experimental design has five test events, which 1) vary the floor of the INL building on which the contaminant will be released, 2) provide for varying the amount of contaminant released to obtain desired concentration gradients, and 3) investigate overt as well as covert release of contaminants. Desirable contaminant gradients would have moderate to low concentrations of contaminant in rooms near the release point, with concentrations down to zero in other rooms. Such gradients would provide a range of contamination levels to challenge the sampling

  11. Acceptability of self-collected versus provider-collected sampling for HPV DNA testing among women in rural El Salvador.

    Science.gov (United States)

    Rosenbaum, Alan J; Gage, Julia C; Alfaro, Karla M; Ditzian, Lauren R; Maza, Mauricio; Scarinci, Isabel C; Felix, Juan C; Castle, Philip E; Villalta, Sofia; Miranda, Esmeralda; Cremer, Miriam L

    2014-08-01

    To determine the acceptability of self-collected versus provider-collected sampling among women participating in public sector HPV-based cervical cancer screening in El Salvador. Two thousand women aged 30-49 years underwent self-collected and provider-collected sampling with careHPV between October 2012 and March 2013 (Qiagen, Gaithersburg, MD, USA). After sample collection, a random sample of women (n=518) were asked about their experience. Participants were questioned regarding sampling method preference, previous cervical cancer screening, HPV and cervical cancer knowledge, HPV risk factors, and demographic information. All 518 women approached to participate in this questionnaire study agreed and were enrolled, 27.8% (142 of 511 responding) of whom had not received cervical cancer screening within the past 3 years and were considered under-screened. Overall, 38.8% (n=201) preferred self-collection and 31.9% (n=165) preferred provider collection. Self-collection preference was associated with prior tubal ligation, HPV knowledge, future self-sampling preference, and future home-screening preference (P<0.05). Reasons for self-collection preference included privacy/embarrassment, ease, and less pain; reasons cited for provider-collection preference were result accuracy and provider knowledge/experience. Self-sampling was found to be acceptable, therefore screening programs could consider offering this option either in the clinic or at home. Self-sampling at home may increase coverage in low-resource countries and reduce the burden that screening places upon clinical infrastructure. Copyright © 2014 International Federation of Gynecology and Obstetrics. All rights reserved.

  12. Collection of Oral Fluids Using Cotton Ropes as a Sampling Method to Detect Foot-and-Mouth Disease Virus Infection in Pigs.

    Science.gov (United States)

    Vosloo, W; Morris, J; Davis, A; Giles, M; Wang, J; Nguyen, H T T; Kim, P V; Quach, N V; Le, P T T; Nguyen, P H N; Dang, H; Tran, H X; Vu, P P; Hung, V V; Le, Q T; Tran, T M; Mai, T M T; Le, Q T V; Singanallur, N B

    2015-10-01

    In high-density farming practices, it is important to constantly monitor for infectious diseases, especially diseases that have the potential to spread rapidly between holdings. Pigs are known to amplify foot-and-mouth disease (FMD) by excreting large amounts of virus, and it is therefore important to detect the virus quickly and accurately to minimize the spread of disease. Ropes were used to collect oral fluid samples from pigs, and each sample was compared to saliva samples collected from individual animals by detecting FMD virus RNA using real-time PCR. Two different experiments are described where groups of pigs were infected with different serotypes of FMD virus, either with or without vaccination, and unvaccinated pigs were kept in aerosol contact. The sensitivity of the rope sampling varied between 0.67 and 0.92, and the statistical agreement between this method and individual sampling ranged from substantial to moderate for the two different serotypes. The ease of collecting oral fluids using ropes together with the high sensitivity of subsequent FMD detection through PCR indicates that this could be a useful method to monitor pig populations for FMD virus infection. With further validation of the sensitivity of detection of FMD virus RNA, this can be a cost-effective, non-invasive diagnostic tool. © 2013 Blackwell Verlag GmbH.

  13. 40 CFR Appendix I to Part 261 - Representative Sampling Methods

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Representative Sampling Methods I...—Representative Sampling Methods The methods and equipment used for sampling waste materials will vary with the form and consistency of the waste materials to be sampled. Samples collected using the sampling...

  14. Subrandom methods for multidimensional nonuniform sampling.

    Science.gov (United States)

    Worley, Bradley

    2016-08-01

    Methods of nonuniform sampling that utilize pseudorandom number sequences to select points from a weighted Nyquist grid are commonplace in biomolecular NMR studies, due to the beneficial incoherence introduced by pseudorandom sampling. However, these methods require the specification of a non-arbitrary seed number in order to initialize a pseudorandom number generator. Because the performance of pseudorandom sampling schedules can substantially vary based on seed number, this can complicate the task of routine data collection. Approaches such as jittered sampling and stochastic gap sampling are effective at reducing random seed dependence of nonuniform sampling schedules, but still require the specification of a seed number. This work formalizes the use of subrandom number sequences in nonuniform sampling as a means of seed-independent sampling, and compares the performance of three subrandom methods to their pseudorandom counterparts using commonly applied schedule performance metrics. Reconstruction results using experimental datasets are also provided to validate claims made using these performance metrics. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Biopolymers for Sample Collection, Protection, and Preservation

    Science.gov (United States)

    2015-05-19

    knowledge of sample collection from various matrices is crucial. Recovery and preservation of microorganisms prior to analysis are important...Another method for encapsulating bacteria for use in biodegradation of gasoline involves a complex process using gellan gum (Moslemy et al. 2002). Many...use of acacia gum in preserving microorganisms for extended periods of time without refrigeration (Krumnow et al. 2009; Sorokulova et al. 2008, 2012

  16. Collection and preparation of water samples for hydrogeochemical reconnaissance

    International Nuclear Information System (INIS)

    Baucom, E.I.; Ferguson, R.B.; Wallace, R.M.

    1977-01-01

    A method based on ion exchange and neutron activation analysis (NAA) was developed and field-tested to determine uranium over the range 0.02 to 10,000 ppb in natural water using a single procedure. Water samples are filtered in the field using a specially-designed one-liter filter apparatus pressurized to 40 psig with an inert gas. The filtered water is treated with a high purity, mixed cation-anion resin in the hydronium-hydroxide form. All ions are removed from solution under the strong driving force of the neutralization reaction. Anionic, cationic, and natural complexes of uranium can be concentrated with this method. Field tests showed greater than 95 percent recovery of 13 elements analyzed (including greater than 99 percent recovery of uranium) and greater than or equal to 90 percent recovery of 4 other elements. Uranium collected on the resin was quantitatively determined by NAA. Coefficient of variation for sampling plus analysis was less than 20 percent for samples containing more than 0.1 ppb uranium. Advantages of this method include: (1) wide dynamic range, (2) low detection limit for uranium (0.02 ppb), (3) high precision and accuracy, (4) relatively low cost, (5) high-yield recovery from low-level aqueous samples without risk of loss to containers, (6) decreased risk of significant sample contamination compared with other low-level methods, (7) production of stable samples suitable for retrievable storage, and(8) concentration of other ions that can be determined by NAA. This paper presents (1) background regarding development of procedures for sample collection and preparation, (2) results of development programs, (3) description of equipment and field procedures, and (4) preliminary conclusions regarding use of this technology for hydrogeochemical reconnaissance for uranium

  17. Equipment for collecting samples of radioactive solutions

    International Nuclear Information System (INIS)

    Raggenbass, A.; Fradin, J.; Joubert, G.

    1958-01-01

    The authors present an equipment aimed at collecting samples of fission products to perform radio-chemical analysis. As the sample must have a total activity between 1 and 50 micro-Curie, this installation comprises a sampling system and a dilution device which aims at bringing the sample to the suitable activity. Samples are collected by means of needles. The sample reproducibility is discussed. The dilution device is described

  18. Fluidics platform and method for sample preparation

    Science.gov (United States)

    Benner, Henry W.; Dzenitis, John M.

    2016-06-21

    Provided herein are fluidics platforms and related methods for performing integrated sample collection and solid-phase extraction of a target component of the sample all in one tube. The fluidics platform comprises a pump, particles for solid-phase extraction and a particle-holding means. The method comprises contacting the sample with one or more reagents in a pump, coupling a particle-holding means to the pump and expelling the waste out of the pump while the particle-holding means retains the particles inside the pump. The fluidics platform and methods herein described allow solid-phase extraction without pipetting and centrifugation.

  19. Analysis of the research sample collections of Uppsala biobank.

    Science.gov (United States)

    Engelmark, Malin T; Beskow, Anna H

    2014-10-01

    Uppsala Biobank is the joint and only biobank organization of the two principals, Uppsala University and Uppsala University Hospital. Biobanks are required to have updated registries on sample collection composition and management in order to fulfill legal regulations. We report here the results from the first comprehensive and overall analysis of the 131 research sample collections organized in the biobank. The results show that the median of the number of samples in the collections was 700 and that the number of samples varied from less than 500 to over one million. Blood samples, such as whole blood, serum, and plasma, were included in the vast majority, 84.0%, of the research sample collections. Also, as much as 95.5% of the newly collected samples within healthcare included blood samples, which further supports the concept that blood samples have fundamental importance for medical research. Tissue samples were also commonly used and occurred in 39.7% of the research sample collections, often combined with other types of samples. In total, 96.9% of the 131 sample collections included samples collected for healthcare, showing the importance of healthcare as a research infrastructure. Of the collections that had accessed existing samples from healthcare, as much as 96.3% included tissue samples from the Department of Pathology, which shows the importance of pathology samples as a resource for medical research. Analysis of different research areas shows that the most common of known public health diseases are covered. Collections that had generated the most publications, up to over 300, contained a large number of samples collected systematically and repeatedly over many years. More knowledge about existing biobank materials, together with public registries on sample collections, will support research collaborations, improve transparency, and bring us closer to the goals of biobanks, which is to save and prolong human lives and improve health and quality of life.

  20. Thar she blows! A novel method for DNA collection from cetacean blow.

    Directory of Open Access Journals (Sweden)

    Céline H Frère

    Full Text Available BACKGROUND: Molecular tools are now widely used to address crucial management and conservation questions. To date, dart biopsying has been the most commonly used method for collecting genetic data from cetaceans; however, this method has some drawbacks. Dart biopsying is considered inappropriate for young animals and has recently come under scrutiny from ethical boards, conservationists, and the general public. Thus, identifying alternative genetic collection techniques for cetaceans remains a priority, especially for internationally protected species. METHODOLOGY/PRINCIPAL FINDINGS: In this study, we investigated whether blow-sampling, which involves collecting exhalations from the blowholes of cetaceans, could be developed as a new less invasive method for DNA collection. Our current methodology was developed using six bottlenose dolphins, Tursiops truncatus, housed at the National Aquarium, Baltimore (USA, from which we were able to collect both blow and blood samples. For all six individuals, we found that their mitochondrial and microsatellite DNA profile taken from blow, matched their corresponding mitochondrial and microsatellite DNA profile collected from blood. This indicates that blow-sampling is a viable alternative method for DNA collection. CONCLUSION/SIGNIFICANCE: In this study, we show that blow-sampling provides a viable and less invasive method for collection of genetic data, even for small cetaceans. In contrast to dart biopsying, the advantage of this method is that it capitalizes on the natural breathing behaviour of dolphins and can be applied to even very young dolphins. Both biopsy and blow-sampling require close proximity of the boat, but blow-sampling can be achieved when dolphins voluntarily bow-ride and involves no harmful contact.

  1. Urine sample collection protocols for bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject`s body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  2. Urine sample collection protocols for bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject's body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  3. Method and apparatus for sampling atmospheric mercury

    Science.gov (United States)

    Trujillo, Patricio E.; Campbell, Evan E.; Eutsler, Bernard C.

    1976-01-20

    A method of simultaneously sampling particulate mercury, organic mercurial vapors, and metallic mercury vapor in the working and occupational environment and determining the amount of mercury derived from each such source in the sampled air. A known volume of air is passed through a sampling tube containing a filter for particulate mercury collection, a first adsorber for the selective adsorption of organic mercurial vapors, and a second adsorber for the adsorption of metallic mercury vapor. Carbon black molecular sieves are particularly useful as the selective adsorber for organic mercurial vapors. The amount of mercury adsorbed or collected in each section of the sampling tube is readily quantitatively determined by flameless atomic absorption spectrophotometry.

  4. Detection of oral HPV infection - Comparison of two different specimen collection methods and two HPV detection methods.

    Science.gov (United States)

    de Souza, Marjorie M A; Hartel, Gunter; Whiteman, David C; Antonsson, Annika

    2018-04-01

    Very little is known about the natural history of oral HPV infection. Several different methods exist to collect oral specimens and detect HPV, but their respective performance characteristics are unknown. We compared two different methods for oral specimen collection (oral saline rinse and commercial saliva kit) from 96 individuals and then analyzed the samples for HPV by two different PCR detection methods (single GP5+/6+ PCR and nested MY09/11 and GP5+/6+ PCR). For the oral rinse samples, the oral HPV prevalence was 10.4% (GP+ PCR; 10% repeatability) vs 11.5% (nested PCR method; 100% repeatability). For the commercial saliva kit samples, the prevalences were 3.1% vs 16.7% with the GP+ PCR vs the nested PCR method (repeatability 100% for both detection methods). Overall the agreement was fair or poor between samples and methods (kappa 0.06-0.36). Standardizing methods of oral sample collection and HPV detection would ensure comparability between future oral HPV studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. 28 CFR 28.12 - Collection of DNA samples.

    Science.gov (United States)

    2010-07-01

    ... Homeland Security, collecting DNA samples from: (1) Aliens lawfully in, or being processed for lawful... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Collection of DNA samples. 28.12 Section 28.12 Judicial Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample Collection...

  6. An international study of the performance of sample collection from patients

    NARCIS (Netherlands)

    Dzik, WH; Murphy, MF; Andreu, G; Heddle, N; Hogman, C; Kekomaki, R; Murphy, S; Shimizu, M; Smit Sibinga, C.T.

    2003-01-01

    Background and Objectives Collection of a blood sample from the correct patient is the first step in the process of safe transfusion. The aim of this international collaborative study was to assess the frequency of mislabelled and miscollected samples drawn for blood grouping. Materials and Methods

  7. Collecting Ground Samples for Balloon-Borne Instruments

    Science.gov (United States)

    Jones, Jack; Zimmerman, Wayne; Wu, Jiunn Jenq

    2009-01-01

    A proposed system in a gondola containing scientific instruments suspended by a balloon over the surface of the Saturn moon Titan would quickly acquire samples of rock or ice from the ground below. Prototypes of a sample-collecting device that would be a major part of the system have been tested under cryogenic and non-cryogenic conditions on Earth. Systems like this one could also be used in non-cryogenic environments on Earth to collect samples of rock, soil, ice, mud, or other ground material from such inaccessible or hazardous locations as sites of suspected chemical spills or biological contamination. The sample-collecting device would be a harpoonlike device that would be connected to the balloon-borne gondola by a tether long enough to reach the ground. The device would be dropped from the gondola to acquire a sample, then would be reeled back up to the gondola, where the sample would be analyzed by the onboard instruments. Each prototype of the sample-collecting device has a sharp front (lower) end, a hollow core for retaining a sample, a spring for holding the sample in the hollow core, and a rear (upper) annular cavity for retaining liquid sample material. Aerodynamic fins at the rear help to keep the front end pointed downward. In tests, these prototype devices were dropped from various heights and used to gather samples of dry sand, moist sand, cryogenic water ice, and warmer water ice.

  8. On the improvement of blood sample collection at clinical laboratories.

    Science.gov (United States)

    Grasas, Alex; Ramalhinho, Helena; Pessoa, Luciana S; Resende, Mauricio G C; Caballé, Imma; Barba, Nuria

    2014-01-09

    Blood samples are usually collected daily from different collection points, such hospitals and health centers, and transported to a core laboratory for testing. This paper presents a project to improve the collection routes of two of the largest clinical laboratories in Spain. These routes must be designed in a cost-efficient manner while satisfying two important constraints: (i) two-hour time windows between collection and delivery, and (ii) vehicle capacity. A heuristic method based on a genetic algorithm has been designed to solve the problem of blood sample collection. The user enters the following information for each collection point: postal address, average collecting time, and average demand (in thermal containers). After implementing the algorithm using C programming, this is run and, in few seconds, it obtains optimal (or near-optimal) collection routes that specify the collection sequence for each vehicle. Different scenarios using various types of vehicles have been considered. Unless new collection points are added or problem parameters are changed substantially, routes need to be designed only once. The two laboratories in this study previously planned routes manually for 43 and 74 collection points, respectively. These routes were covered by an external carrier company. With the implementation of this algorithm, the number of routes could be reduced from ten to seven in one laboratory and from twelve to nine in the other, which represents significant annual savings in transportation costs. The algorithm presented can be easily implemented in other laboratories that face this type of problem, and it is particularly interesting and useful as the number of collection points increases. The method designs blood collection routes with reduced costs that meet the time and capacity constraints of the problem.

  9. Two-point vs multipoint sample collection for the analysis of energy expenditure by use of the doubly labeled water method

    International Nuclear Information System (INIS)

    Welle, S.

    1990-01-01

    Energy expenditure over a 2-wk period was determined by the doubly labeled water (2H2(18)O) method in nine adults. When daily samples were analyzed, energy expenditure was 2859 +/- 453 kcal/d (means +/- SD); when only the first and last time points were considered, the mean calculated energy expenditure was not significantly different (2947 +/- 430 kcal/d). An analysis of theoretical cases in which isotope flux is not constant indicates that the multipoint method can cause errors in the calculation of average isotope fluxes, but these are generally small. Simulations of the effect of analytical error indicate that increasing the number of replicates on two points reduces the impact of technical errors more effectively than does performing single analyses on multiple samples. It appears that generally there is no advantage to collecting frequent samples when the 2H2(18)O method is used to estimate energy expenditure in adult humans

  10. Self-Collected versus Clinician-Collected Sampling for Chlamydia and Gonorrhea Screening: A Systemic Review and Meta-Analysis

    Science.gov (United States)

    Lunny, Carole; Taylor, Darlene; Hoang, Linda; Wong, Tom; Gilbert, Mark; Lester, Richard; Krajden, Mel; Ogilvie, Gina

    2015-01-01

    Background The increases in STI rates since the late 1990s in Canada have occurred despite widespread primary care and targeted public health programs and in the setting of universal health care. More innovative interventions are required that would eliminate barriers to STI testing such as internet-based or mail-in home and community service testing for patients that are hard to reach, who refuse to go for clinician-based testing, or who decline an examination. Jurisdictions such as New Zealand and some American states currently use self-collected sampling, but without the required evidence to determine whether self-collected specimens are as accurate as clinician-collected specimens in terms of chlamydia and gonorrhea diagnostic accuracy. The objective of the review is to compare self-collected vaginal, urine, pharyngeal and rectal samples to our reference standard - clinician-collected cervical, urethral, pharyngeal and rectal sampling techniques to identify a positive specimen using nucleic acid amplification test assays. Methods The hierarchical summary receiver operating characteristic and the fixed effect models were used to assess the accuracy of comparable specimens that were collected by patients compared to clinicians. Sensitivity and specificity estimates with 95% confidence intervals (CI) were reported as our main outcome measures. Findings We included 21 studies based on over 6100 paired samples. Fourteen included studies examined chlamydia only, 6 compared both gonorrhea and chlamydia separately in the same study, and one examined gonorrhea. The six chlamydia studies comparing self-collection by vaginal swab to a clinician-collected cervical swab had the highest sensitivity (92%, 95% CI 87-95) and specificity (98%, 95% CI 97-99), compared to other specimen-types (urine/urethra or urine/cervix). Six studies compared urine self-samples to urethra clinician-collected samples in males and produced a sensitivity of 88% (95% CI 83-93) and a specificity of

  11. 40 CFR 80.8 - Sampling methods for gasoline and diesel fuel.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Sampling methods for gasoline and... PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES General Provisions § 80.8 Sampling methods for gasoline and diesel fuel. The sampling methods specified in this section shall be used to collect samples...

  12. The Apollo lunar samples collection analysis and results

    CERN Document Server

    Young, Anthony

    2017-01-01

    This book focuses on the specific mission planning for lunar sample collection, the equipment used, and the analysis and findings concerning the samples at the Lunar Receiving Laboratory in Texas. Anthony Young documents the collection of Apollo samples for the first time for readers of all backgrounds, and includes interviews with many of those involved in planning and analyzing the samples. NASA contracted with the U.S. Geologic Survey to perform classroom and field training of the Apollo astronauts. NASA’s Geology Group within the Manned Spacecraft Center in Houston, Texas, helped to establish the goals of sample collection, as well as the design of sample collection tools, bags, and storage containers. In this book, detailed descriptions are given on the design of the lunar sampling tools, the Modular Experiment Transporter used on Apollo 14, and the specific areas of the Lunar Rover vehicle used for the Apollo 15, 16, and 17 missions, which carried the sampling tools, bags, and other related equipment ...

  13. Collection of biological samples in forensic toxicology.

    Science.gov (United States)

    Dinis-Oliveira, R J; Carvalho, F; Duarte, J A; Remião, F; Marques, A; Santos, A; Magalhães, T

    2010-09-01

    Forensic toxicology is the study and practice of the application of toxicology to the purposes of the law. The relevance of any finding is determined, in the first instance, by the nature and integrity of the specimen(s) submitted for analysis. This means that there are several specific challenges to select and collect specimens for ante-mortem and post-mortem toxicology investigation. Post-mortem specimens may be numerous and can endow some special difficulties compared to clinical specimens, namely those resulting from autolytic and putrefactive changes. Storage stability is also an important issue to be considered during the pre-analytic phase, since its consideration should facilitate the assessment of sample quality and the analytical result obtained from that sample. The knowledge on degradation mechanisms and methods to increase storage stability may enable the forensic toxicologist to circumvent possible difficulties. Therefore, advantages and limitations of specimen preservation procedures are thoroughfully discussed in this review. Presently, harmonized protocols for sampling in suspected intoxications would have obvious utility. In the present article an overview is given on sampling procedures for routinely collected specimens as well as on alternative specimens that may provide additional information on the route and timing of exposure to a specific xenobiotic. Last, but not least, a discussion on possible bias that can influence the interpretation of toxicological results is provided. This comprehensive review article is intented as a significant help for forensic toxicologists to accomplish their frequently overwhelming mission.

  14. The Autism Simplex Collection : an international, expertly phenotyped autism sample for genetic and phenotypic analyses

    OpenAIRE

    Buxbaum, Joseph D.; Bolshakova, Nadia; Brownfeld, Jessica M.; Anney, Richard J. L.; Bender, Patrick; Bernier, Raphael; Cook, Edwin H.; Coon, Hilary; Cuccaro, Michael L.; Freitag, Christine M.; Hallmayer, Joachim; Geschwind, Daniel H.; Klauck, Sabine M.; Nurnberger, John I.; Oliveira, Guiomar

    2014-01-01

    Background: There is an urgent need for expanding and enhancing autism spectrum disorder (ASD) samples, in order to better understand causes of ASD. Methods: In a unique public-private partnership, 13 sites with extensive experience in both the assessment and diagnosis of ASD embarked on an ambitious, 2-year program to collect samples for genetic and phenotypic research and begin analyses on these samples. The program was called The Autism Simplex Collection (TASC). TASC sample collection ...

  15. Estimation of creatinine in Urine sample by Jaffe's method

    International Nuclear Information System (INIS)

    Wankhede, Sonal; Arunkumar, Suja; Sawant, Pramilla D.; Rao, B.B.

    2012-01-01

    In-vitro bioassay monitoring is based on the determination of activity concentrations in biological samples excreted from the body and is most suitable for alpha and beta emitters. A truly representative bioassay sample is the one having all the voids collected during a 24-h period however, this being technically difficult, overnight urine samples collected by the workers are analyzed. These overnight urine samples are collected for 10-16 h, however in the absence of any specific information, 12 h duration is assumed and the observed results are then corrected accordingly obtain the daily excretion rate. To reduce the uncertainty due to unknown duration of sample collection, IAEA has recommended two methods viz., measurement of specific gravity and creatinine excretion rate in urine sample. Creatinine is a final metabolic product creatinine phosphate in the body and is excreted at a steady rate for people with normally functioning kidneys. It is, therefore, often used as a normalization factor for estimation of duration of sample collection. The present study reports the chemical procedure standardized and its application for the estimation of creatinine in urine samples collected from occupational workers. Chemical procedure for estimation of creatinine in bioassay samples was standardized and applied successfully for its estimation in bioassay samples collected from the workers. The creatinine excretion rate observed for these workers is lower than observed in literature. Further, work is in progress to generate a data bank of creatinine excretion rate for most of the workers and also to study the variability in creatinine coefficient for the same individual based on the analysis of samples collected for different duration

  16. Validation of a Sampling Method to Collect Exposure Data for Central-Line-Associated Bloodstream Infections.

    Science.gov (United States)

    Hammami, Naïma; Mertens, Karl; Overholser, Rosanna; Goetghebeur, Els; Catry, Boudewijn; Lambert, Marie-Laurence

    2016-05-01

    Surveillance of central-line-associated bloodstream infections requires the labor-intensive counting of central-line days (CLDs). This workload could be reduced by sampling. Our objective was to evaluate the accuracy of various sampling strategies in the estimation of CLDs in intensive care units (ICUs) and to establish a set of rules to identify optimal sampling strategies depending on ICU characteristics. Analyses of existing data collected according to the European protocol for patient-based surveillance of ICU-acquired infections in Belgium between 2004 and 2012. CLD data were reported by 56 ICUs in 39 hospitals during 364 trimesters. We compared estimated CLD data obtained from weekly and monthly sampling schemes with the observed exhaustive CLD data over the trimester by assessing the CLD percentage error (ie, observed CLDs - estimated CLDs/observed CLDs). We identified predictors of improved accuracy using linear mixed models. When sampling once per week or 3 times per month, 80% of ICU trimesters had a CLD percentage error within 10%. When sampling twice per week, this was >90% of ICU trimesters. Sampling on Tuesdays provided the best estimations. In the linear mixed model, the observed CLD count was the best predictor for a smaller percentage error. The following sampling strategies provided an estimate within 10% of the actual CLD for 97% of the ICU trimesters with 90% confidence: 3 times per month in an ICU with >650 CLDs per trimester or each Tuesday in an ICU with >480 CLDs per trimester. Sampling of CLDs provides an acceptable alternative to daily collection of CLD data.

  17. A self-sampling method to obtain large volumes of undiluted cervicovaginal secretions.

    Science.gov (United States)

    Boskey, Elizabeth R; Moench, Thomas R; Hees, Paul S; Cone, Richard A

    2003-02-01

    Studies of vaginal physiology and pathophysiology sometime require larger volumes of undiluted cervicovaginal secretions than can be obtained by current methods. A convenient method for self-sampling these secretions outside a clinical setting can facilitate such studies of reproductive health. The goal was to develop a vaginal self-sampling method for collecting large volumes of undiluted cervicovaginal secretions. A menstrual collection device (the Instead cup) was inserted briefly into the vagina to collect secretions that were then retrieved from the cup by centrifugation in a 50-ml conical tube. All 16 women asked to perform this procedure found it feasible and acceptable. Among 27 samples, an average of 0.5 g of secretions (range, 0.1-1.5 g) was collected. This is a rapid and convenient self-sampling method for obtaining relatively large volumes of undiluted cervicovaginal secretions. It should prove suitable for a wide range of assays, including those involving sexually transmitted diseases, microbicides, vaginal physiology, immunology, and pathophysiology.

  18. Small Body GN and C Research Report: G-SAMPLE - An In-Flight Dynamical Method for Identifying Sample Mass [External Release Version

    Science.gov (United States)

    Carson, John M., III; Bayard, David S.

    2006-01-01

    G-SAMPLE is an in-flight dynamical method for use by sample collection missions to identify the presence and quantity of collected sample material. The G-SAMPLE method implements a maximum-likelihood estimator to identify the collected sample mass, based on onboard force sensor measurements, thruster firings, and a dynamics model of the spacecraft. With G-SAMPLE, sample mass identification becomes a computation rather than an extra hardware requirement; the added cost of cameras or other sensors for sample mass detection is avoided. Realistic simulation examples are provided for a spacecraft configuration with a sample collection device mounted on the end of an extended boom. In one representative example, a 1000 gram sample mass is estimated to within 110 grams (95% confidence) under realistic assumptions of thruster profile error, spacecraft parameter uncertainty, and sensor noise. For convenience to future mission design, an overall sample-mass estimation error budget is developed to approximate the effect of model uncertainty, sensor noise, data rate, and thrust profile error on the expected estimate of collected sample mass.

  19. Sampling and analysis methods for geothermal fluids and gases

    Energy Technology Data Exchange (ETDEWEB)

    Shannon, D. W.

    1978-01-01

    The data obtained for the first round robin sample collected at Mesa 6-2 wellhead, East Mesa Test Site, Imperial Valley are summarized. Test results are listed by method used for cross reference to the analytic methods section. Results obtained for radioactive isotopes present in the brine sample are tabulated. The data obtained for the second round robin sample collected from the Woolsey No. 1 first stage flash unit, San Diego Gas and Electric Niland Test Facility are presented in the same manner. Lists of the participants of the two round robins are given. Data from miscellaneous analyses are included. Summaries of values derived from the round robin raw data are presented. (MHR)

  20. The development of a Martian atmospheric Sample collection canister

    Science.gov (United States)

    Kulczycki, E.; Galey, C.; Kennedy, B.; Budney, C.; Bame, D.; Van Schilfgaarde, R.; Aisen, N.; Townsend, J.; Younse, P.; Piacentine, J.

    The collection of an atmospheric sample from Mars would provide significant insight to the understanding of the elemental composition and sub-surface out-gassing rates of noble gases. A team of engineers at the Jet Propulsion Laboratory (JPL), California Institute of Technology have developed an atmospheric sample collection canister for Martian application. The engineering strategy has two basic elements: first, to collect two separately sealed 50 cubic centimeter unpressurized atmospheric samples with minimal sensing and actuation in a self contained pressure vessel; and second, to package this atmospheric sample canister in such a way that it can be easily integrated into the orbiting sample capsule for collection and return to Earth. Sample collection and integrity are demonstrated by emulating the atmospheric collection portion of the Mars Sample Return mission on a compressed timeline. The test results achieved by varying the pressure inside of a thermal vacuum chamber while opening and closing the valve on the sample canister at Mars ambient pressure. A commercial off-the-shelf medical grade micro-valve is utilized in the first iteration of this design to enable rapid testing of the system. The valve has been independently leak tested at JPL to quantify and separate the leak rates associated with the canister. The results are factored in to an overall system design that quantifies mass, power, and sensing requirements for a Martian atmospheric Sample Collection (MASC) canister as outlined in the Mars Sample Return mission profile. Qualitative results include the selection of materials to minimize sample contamination, preliminary science requirements, priorities in sample composition, flight valve selection criteria, a storyboard from sample collection to loading in the orbiting sample capsule, and contributions to maintaining “ Earth” clean exterior surfaces on the orbiting sample capsule.

  1. Self-collected versus clinician-collected sampling for sexually transmitted infections: a systematic review and meta-analysis protocol.

    Science.gov (United States)

    Taylor, Darlene; Lunny, Carole; Wong, Tom; Gilbert, Mark; Li, Neville; Lester, Richard; Krajden, Mel; Hoang, Linda; Ogilvie, Gina

    2013-10-10

    Three meta-analyses and one systematic review have been conducted on the question of whether self-collected specimens are as accurate as clinician-collected specimens for STI screening. However, these reviews predate 2007 and did not analyze rectal or pharyngeal collection sites. Currently, there is no consensus on which sampling method is the most effective for the diagnosis of genital chlamydia (CT), gonorrhea (GC) or human papillomavirus (HPV) infection. Our meta-analysis aims to be comprehensive in that it will examine the evidence of whether self-collected vaginal, urine, pharyngeal and rectal specimens provide as accurate a clinical diagnosis as clinician-collected samples (reference standard). Eligible studies include both randomized and non-randomized controlled trials, pre- and post-test designs, and controlled observational studies. The databases that will be searched include the Cochrane Database of Systematic Reviews, Web of Science, Database of Abstracts of Reviews of Effects (DARE), EMBASE and PubMed/Medline. Data will be abstracted independently by two reviewers using a standardized pre-tested data abstraction form. Heterogeneity will be assessed using the Q2 test. Sensitivity and specificity estimates with 95% confidence intervals as well as negative and positive likelihood ratios will be pooled and weighted using random effects meta-analysis, if appropriate. A hierarchical summary receiver operating characteristics curve for self-collected specimens will be generated. This synthesis involves a meta-analysis of self-collected samples (urine, vaginal, pharyngeal and rectal swabs) versus clinician-collected samples for the diagnosis of CT, GC and HPV, the most prevalent STIs. Our systematic review will allow patients, clinicians and researchers to determine the diagnostic accuracy of specimens collected by patients compared to those collected by clinicians in the detection of chlamydia, gonorrhea and HPV.

  2. The U.S. Geological Survey Geologic Collections Management System (GCMS)—A master catalog and collections management plan for U.S. Geological Survey geologic samples and sample collections

    Science.gov (United States)

    ,

    2015-01-01

    The U.S. Geological Survey (USGS) is widely recognized in the earth science community as possessing extensive collections of earth materials collected by research personnel over the course of its history. In 2006, a Geologic Collections Inventory was conducted within the USGS Geology Discipline to determine the extent and nature of its sample collections, and in 2008, a working group was convened by the USGS National Geologic and Geophysical Data Preservation Program to examine ways in which these collections could be coordinated, cataloged, and made available to researchers both inside and outside the USGS. The charge to this working group was to evaluate the proposition of creating a Geologic Collections Management System (GCMS), a centralized database that would (1) identify all existing USGS geologic collections, regardless of size, (2) create a virtual link among the collections, and (3) provide a way for scientists and other researchers to obtain access to the samples and data in which they are interested. Additionally, the group was instructed to develop criteria for evaluating current collections and to establish an operating plan and set of standard practices for handling, identifying, and managing future sample collections. Policies and procedures promoted by the GCMS would be based on extant best practices established by the National Science Foundation and the Smithsonian Institution. The resulting report—USGS Circular 1410, “The U.S. Geological Survey Geologic Collections Management System (GCMS): A Master Catalog and Collections Management Plan for U.S. Geological Survey Geologic Samples and Sample Collections”—has been developed for sample repositories to be a guide to establishing common practices in the collection, retention, and disposal of geologic research materials throughout the USGS.

  3. Evaluation of a novel dried blood spot collection device (HemaSpot™) to test blood samples collected from dogs for antibodies to Leishmania infantum.

    Science.gov (United States)

    Rosypal, Alexa C; Pick, Leanne D; Hernandez, Jaime O Esquivel; Lindsay, David S

    2014-09-15

    Collection of blood samples from veterinary and wildlife patients is often challenging because the samples have to be collected on farm or in the wild under various environmental conditions. This poses many technical problems associated with venipuncture materials, their safe use and disposal, transportation and processing of collected samples. Dried blood spot (DBS) sample collection techniques offer a simple and practical alternative to traditional blood collection methods to obtain blood samples from animals for parasite antibody evaluation. The DBS collection devices are compact, simple to use, and are particularly useful for large number of samples. Additionally, DBS samples take up less space and they are easier to transport than traditional venipuncture-collected blood samples. Visceral leishmaniasis (VL) is a potentially fatal parasitic disease of dogs and humans and it is frequently diagnosed by antibody tests. Immunochromatographic tests (ICT) for antibodies to Leishmania infantum are commercially available for dogs and they produce qualitative results in minutes. Measurement of canine antibodies to L. infantum with the ICT using traditional venipuncture has been validated previously, but the use of DBS samples has not been evaluated using this method. The purpose of the present study was to determine the ability of DBS samples to detect antibodies to L. infantum in dogs using a commercial ICT assay. One hundred plasma samples from dogs experimentally infected with the LIVT-1 strain of L. infantum were collected by venipuncture and frozen. Individual samples were thawed, and then 80 μl plasma (2 drops) was aliquotted onto the 8-spoked disk pad on individual DBS sample collection devices (HemaSpot™, Spot-On Sciences, Austin, TX), dried, and stored in the dark at room temperature. After one month and six months, respectively, 2 spokes of the 8 spokes of the disk pad of each DBS sample were removed and eluted in 200 μl PBS. The eluate was used to test

  4. Sampling and examination methods used for TMI-2 samples

    International Nuclear Information System (INIS)

    Marley, A.W.; Akers, D.W.; McIsaac, C.V.

    1988-01-01

    The purpose of this paper is to summarize the sampling and examination techniques that were used in the collection and analysis of TMI-2 samples. Samples ranging from auxiliary building air to core debris were collected and analyzed. Handling of the larger samples and many of the smaller samples had to be done remotely and many standard laboratory analytical techniques were modified to accommodate the extremely high radiation fields associated with these samples. The TMI-2 samples presented unique problems with sampling and the laboratory analysis of prior molten fuel debris. 14 refs., 8 figs

  5. Survey research with a random digit dial national mobile phone sample in Ghana: Methods and sample quality

    Science.gov (United States)

    Sefa, Eunice; Adimazoya, Edward Akolgo; Yartey, Emmanuel; Lenzi, Rachel; Tarpo, Cindy; Heward-Mills, Nii Lante; Lew, Katherine; Ampeh, Yvonne

    2018-01-01

    Introduction Generating a nationally representative sample in low and middle income countries typically requires resource-intensive household level sampling with door-to-door data collection. High mobile phone penetration rates in developing countries provide new opportunities for alternative sampling and data collection methods, but there is limited information about response rates and sample biases in coverage and nonresponse using these methods. We utilized data from an interactive voice response, random-digit dial, national mobile phone survey in Ghana to calculate standardized response rates and assess representativeness of the obtained sample. Materials and methods The survey methodology was piloted in two rounds of data collection. The final survey included 18 demographic, media exposure, and health behavior questions. Call outcomes and response rates were calculated according to the American Association of Public Opinion Research guidelines. Sample characteristics, productivity, and costs per interview were calculated. Representativeness was assessed by comparing data to the Ghana Demographic and Health Survey and the National Population and Housing Census. Results The survey was fielded during a 27-day period in February-March 2017. There were 9,469 completed interviews and 3,547 partial interviews. Response, cooperation, refusal, and contact rates were 31%, 81%, 7%, and 39% respectively. Twenty-three calls were dialed to produce an eligible contact: nonresponse was substantial due to the automated calling system and dialing of many unassigned or non-working numbers. Younger, urban, better educated, and male respondents were overrepresented in the sample. Conclusions The innovative mobile phone data collection methodology yielded a large sample in a relatively short period. Response rates were comparable to other surveys, although substantial coverage bias resulted from fewer women, rural, and older residents completing the mobile phone survey in

  6. Evaluation of sampling methods for the detection of Salmonella in broiler flocks

    DEFF Research Database (Denmark)

    Skov, Marianne N.; Carstensen, B.; Tornoe, N.

    1999-01-01

    The present study compares four different sampling methods potentially applicable to detection of Salmonella in broiler flocks, based on collection of faecal samples (i) by hand, 300 fresh faecal samples (ii) absorbed on five sheets of paper (iii) absorbed on five pairs of socks (elastic cotton...... horizontal or vertical) were found in the investigation. The results showed that the sock method (five pairs of socks) had a sensitivity comparable with the hand collection method (60 pools of five faecal samples); the paper collection method was inferior, as was the use of only one pair of socks, Estimation...... tubes pulled over the boots and termed 'socks') and (iv) by using only one pair of socks. Twenty-three broiler flocks were included in the investigation and 18 of these were found to be positive by at least one method. Seven serotypes of Salmonella with different patterns of transmission (mainly...

  7. Standardizing operational vector sampling techniques for measuring malaria transmission intensity: evaluation of six mosquito collection methods in western Kenya.

    Science.gov (United States)

    Wong, Jacklyn; Bayoh, Nabie; Olang, George; Killeen, Gerry F; Hamel, Mary J; Vulule, John M; Gimnig, John E

    2013-04-30

    Operational vector sampling methods lack standardization, making quantitative comparisons of malaria transmission across different settings difficult. Human landing catch (HLC) is considered the research gold standard for measuring human-mosquito contact, but is unsuitable for large-scale sampling. This study assessed mosquito catch rates of CDC light trap (CDC-LT), Ifakara tent trap (ITT), window exit trap (WET), pot resting trap (PRT), and box resting trap (BRT) relative to HLC in western Kenya to 1) identify appropriate methods for operational sampling in this region, and 2) contribute to a larger, overarching project comparing standardized evaluations of vector trapping methods across multiple countries. Mosquitoes were collected from June to July 2009 in four districts: Rarieda, Kisumu West, Nyando, and Rachuonyo. In each district, all trapping methods were rotated 10 times through three houses in a 3 × 3 Latin Square design. Anophelines were identified by morphology and females classified as fed or non-fed. Anopheles gambiae s.l. were further identified as Anopheles gambiae s.s. or Anopheles arabiensis by PCR. Relative catch rates were estimated by negative binomial regression. When data were pooled across all four districts, catch rates (relative to HLC indoor) for An. gambiae s.l (95.6% An. arabiensis, 4.4% An. gambiae s.s) were high for HLC outdoor (RR = 1.01), CDC-LT (RR = 1.18), and ITT (RR = 1.39); moderate for WET (RR = 0.52) and PRT outdoor (RR = 0.32); and low for all remaining types of resting traps (PRT indoor, BRT indoor, and BRT outdoor; RR < 0.08 for all). For Anopheles funestus, relative catch rates were high for ITT (RR = 1.21); moderate for HLC outdoor (RR = 0.47), CDC-LT (RR = 0.69), and WET (RR = 0.49); and low for all resting traps (RR < 0.02 for all). At finer geographic scales, however, efficacy of each trap type varied from district to district. ITT, CDC-LT, and WET appear to be effective methods for large-scale vector sampling in

  8. Measuring larval nematode contamination on cattle pastures: Comparing two herbage sampling methods.

    Science.gov (United States)

    Verschave, S H; Levecke, B; Duchateau, L; Vercruysse, J; Charlier, J

    2015-06-15

    Assessing levels of pasture larval contamination is frequently used to study the population dynamics of the free-living stages of parasitic nematodes of livestock. Direct quantification of infective larvae (L3) on herbage is the most applied method to measure pasture larval contamination. However, herbage collection remains labour intensive and there is a lack of studies addressing the variation induced by the sampling method and the required sample size. The aim of this study was (1) to compare two different sampling methods in terms of pasture larval count results and time required to sample, (2) to assess the amount of variation in larval counts at the level of sample plot, pasture and season, respectively and (3) to calculate the required sample size to assess pasture larval contamination with a predefined precision using random plots across pasture. Eight young stock pastures of different commercial dairy herds were sampled in three consecutive seasons during the grazing season (spring, summer and autumn). On each pasture, herbage samples were collected through both a double-crossed W-transect with samples taken every 10 steps (method 1) and four random located plots of 0.16 m(2) with collection of all herbage within the plot (method 2). The average (± standard deviation (SD)) pasture larval contamination using sampling methods 1 and 2 was 325 (± 479) and 305 (± 444)L3/kg dry herbage (DH), respectively. Large discrepancies in pasture larval counts of the same pasture and season were often seen between methods, but no significant difference (P = 0.38) in larval counts between methods was found. Less time was required to collect samples with method 2. This difference in collection time between methods was most pronounced for pastures with a surface area larger than 1 ha. The variation in pasture larval counts from samples generated by random plot sampling was mainly due to the repeated measurements on the same pasture in the same season (residual variance

  9. Importance of sampling frequency when collecting diatoms

    KAUST Repository

    Wu, Naicheng

    2016-11-14

    There has been increasing interest in diatom-based bio-assessment but we still lack a comprehensive understanding of how to capture diatoms’ temporal dynamics with an appropriate sampling frequency (ASF). To cover this research gap, we collected and analyzed daily riverine diatom samples over a 1-year period (25 April 2013–30 April 2014) at the outlet of a German lowland river. The samples were classified into five clusters (1–5) by a Kohonen Self-Organizing Map (SOM) method based on similarity between species compositions over time. ASFs were determined to be 25 days at Cluster 2 (June-July 2013) and 13 days at Cluster 5 (February-April 2014), whereas no specific ASFs were found at Cluster 1 (April-May 2013), 3 (August-November 2013) (>30 days) and Cluster 4 (December 2013 - January 2014) (<1 day). ASFs showed dramatic seasonality and were negatively related to hydrological wetness conditions, suggesting that sampling interval should be reduced with increasing catchment wetness. A key implication of our findings for freshwater management is that long-term bio-monitoring protocols should be developed with the knowledge of tracking algal temporal dynamics with an appropriate sampling frequency.

  10. Comparability of river suspended-sediment sampling and laboratory analysis methods

    Science.gov (United States)

    Groten, Joel T.; Johnson, Gregory D.

    2018-03-06

    Accurate measurements of suspended sediment, a leading water-quality impairment in many Minnesota rivers, are important for managing and protecting water resources; however, water-quality standards for suspended sediment in Minnesota are based on grab field sampling and total suspended solids (TSS) laboratory analysis methods that have underrepresented concentrations of suspended sediment in rivers compared to U.S. Geological Survey equal-width-increment or equal-discharge-increment (EWDI) field sampling and suspended sediment concentration (SSC) laboratory analysis methods. Because of this underrepresentation, the U.S. Geological Survey, in collaboration with the Minnesota Pollution Control Agency, collected concurrent grab and EWDI samples at eight sites to compare results obtained using different combinations of field sampling and laboratory analysis methods.Study results determined that grab field sampling and TSS laboratory analysis results were biased substantially low compared to EWDI sampling and SSC laboratory analysis results, respectively. Differences in both field sampling and laboratory analysis methods caused grab and TSS methods to be biased substantially low. The difference in laboratory analysis methods was slightly greater than field sampling methods.Sand-sized particles had a strong effect on the comparability of the field sampling and laboratory analysis methods. These results indicated that grab field sampling and TSS laboratory analysis methods fail to capture most of the sand being transported by the stream. The results indicate there is less of a difference among samples collected with grab field sampling and analyzed for TSS and concentration of fines in SSC. Even though differences are present, the presence of strong correlations between SSC and TSS concentrations provides the opportunity to develop site specific relations to address transport processes not captured by grab field sampling and TSS laboratory analysis methods.

  11. Comparison of indoor air sampling and dust collection methods for fungal exposure assessment using quantitative PCR

    Science.gov (United States)

    Evaluating fungal contamination indoors is complicated because of the many different sampling methods utilized. In this study, fungal contamination was evaluated using five sampling methods and four matrices for results. The five sampling methods were a 48 hour indoor air sample ...

  12. The CUPID (Cultural and Psychosocial Influences on Disability) Study: Methods of Data Collection and Characteristics of Study Sample

    Science.gov (United States)

    Coggon, David; Ntani, Georgia; Palmer, Keith T.; Felli, Vanda E.; Harari, Raul; Barrero, Lope H.; Felknor, Sarah A.; Gimeno, David; Cattrell, Anna; Serra, Consol; Bonzini, Matteo; Solidaki, Eleni; Merisalu, Eda; Habib, Rima R.; Sadeghian, Farideh; Kadir, Masood; Warnakulasuriya, Sudath S. P.; Matsudaira, Ko; Nyantumbu, Busisiwe; Sim, Malcolm R.; Harcombe, Helen; Cox, Ken; Marziale, Maria H.; Sarquis, Leila M.; Harari, Florencia; Freire, Rocio; Harari, Natalia; Monroy, Magda V.; Quintana, Leonardo A.; Rojas, Marianela; Salazar Vega, Eduardo J.; Harris, E. Clare; Vargas-Prada, Sergio; Martinez, J. Miguel; Delclos, George; Benavides, Fernando G.; Carugno, Michele; Ferrario, Marco M.; Pesatori, Angela C.; Chatzi, Leda; Bitsios, Panos; Kogevinas, Manolis; Oha, Kristel; Sirk, Tuuli; Sadeghian, Ali; Peiris-John, Roshini J.; Sathiakumar, Nalini; Wickremasinghe, A. Rajitha; Yoshimura, Noriko; Kielkowski, Danuta; Kelsall, Helen L.; Hoe, Victor C. W.; Urquhart, Donna M.; Derett, Sarah; McBride, David; Gray, Andrew

    2012-01-01

    Background The CUPID (Cultural and Psychosocial Influences on Disability) study was established to explore the hypothesis that common musculoskeletal disorders (MSDs) and associated disability are importantly influenced by culturally determined health beliefs and expectations. This paper describes the methods of data collection and various characteristics of the study sample. Methods/Principal Findings A standardised questionnaire covering musculoskeletal symptoms, disability and potential risk factors, was used to collect information from 47 samples of nurses, office workers, and other (mostly manual) workers in 18 countries from six continents. In addition, local investigators provided data on economic aspects of employment for each occupational group. Participation exceeded 80% in 33 of the 47 occupational groups, and after pre-specified exclusions, analysis was based on 12,426 subjects (92 to 1018 per occupational group). As expected, there was high usage of computer keyboards by office workers, while nurses had the highest prevalence of heavy manual lifting in all but one country. There was substantial heterogeneity between occupational groups in economic and psychosocial aspects of work; three- to five-fold variation in awareness of someone outside work with musculoskeletal pain; and more than ten-fold variation in the prevalence of adverse health beliefs about back and arm pain, and in awareness of terms such as “repetitive strain injury” (RSI). Conclusions/Significance The large differences in psychosocial risk factors (including knowledge and beliefs about MSDs) between occupational groups should allow the study hypothesis to be addressed effectively. PMID:22792189

  13. A 'feather-trap' for collecting DNA samples from birds.

    Science.gov (United States)

    Maurer, Golo; Beck, Nadeena; Double, Michael C

    2010-01-01

    Genetic analyses of birds are usually based on DNA extracted from a blood sample. For some species, however, obtaining blood samples is difficult because they are sensitive to handling, pose a conservation or animal welfare concern, or evade capture. In such cases, feathers obtained from live birds in the wild can provide an alternative source of DNA. Here, we provide the first description and evaluation of a 'feather-trap', consisting of small strips of double-sided adhesive tape placed close to a nest with chicks, as a simple, inexpensive and minimally invasive method to collect feathers. The feather-trap was tested in tropical conditions on the Australian pheasant coucal (Centropus phasianinus). None of the 12 pairs of coucals on which the feather-trap was used abandoned the nest, and feeding rates did not differ from those of birds not exposed to a feather-trap. On average, 4.2 feathers were collected per trap over 2-5 days and, despite exposure to monsoonal rain, DNA was extracted from 71.4% of samples, albeit at low concentrations. The amount of genomic DNA extracted from each feather was sufficient to reliably genotype individuals at up to five microsatellite loci for parentage analysis. We show that a feather-trap can provide a reliable alternative for obtaining DNA in species where taking blood is difficult. It may also prove useful for collecting feather samples for other purposes, e.g. stable-isotope analysis. © 2009 Blackwell Publishing Ltd.

  14. Purposeful Sampling for Qualitative Data Collection and Analysis in Mixed Method Implementation Research.

    Science.gov (United States)

    Palinkas, Lawrence A; Horwitz, Sarah M; Green, Carla A; Wisdom, Jennifer P; Duan, Naihua; Hoagwood, Kimberly

    2015-09-01

    Purposeful sampling is widely used in qualitative research for the identification and selection of information-rich cases related to the phenomenon of interest. Although there are several different purposeful sampling strategies, criterion sampling appears to be used most commonly in implementation research. However, combining sampling strategies may be more appropriate to the aims of implementation research and more consistent with recent developments in quantitative methods. This paper reviews the principles and practice of purposeful sampling in implementation research, summarizes types and categories of purposeful sampling strategies and provides a set of recommendations for use of single strategy or multistage strategy designs, particularly for state implementation research.

  15. Purposeful sampling for qualitative data collection and analysis in mixed method implementation research

    Science.gov (United States)

    Palinkas, Lawrence A.; Horwitz, Sarah M.; Green, Carla A.; Wisdom, Jennifer P.; Duan, Naihua; Hoagwood, Kimberly

    2013-01-01

    Purposeful sampling is widely used in qualitative research for the identification and selection of information-rich cases related to the phenomenon of interest. Although there are several different purposeful sampling strategies, criterion sampling appears to be used most commonly in implementation research. However, combining sampling strategies may be more appropriate to the aims of implementation research and more consistent with recent developments in quantitative methods. This paper reviews the principles and practice of purposeful sampling in implementation research, summarizes types and categories of purposeful sampling strategies and provides a set of recommendations for use of single strategy or multistage strategy designs, particularly for state implementation research. PMID:24193818

  16. Increased recovery of touch DNA evidence using FTA paper compared to conventional collection methods.

    Science.gov (United States)

    Kirgiz, Irina A; Calloway, Cassandra

    2017-04-01

    Tape lifting and FTA paper scraping methods were directly compared to traditional double swabbing for collecting touch DNA from car steering wheels (n = 70 cars). Touch DNA was collected from the left or right side of each steering wheel (randomized) using two sterile cotton swabs, while the other side was sampled using water-soluble tape or FTA paper cards. DNA was extracted and quantified in duplicate using qPCR. Quantifiable amounts of DNA were detected for 100% of the samples (n = 140) collected independent of the method. However, the DNA collection yield was dependent on the collection method. A statistically significant difference in DNA yield was observed between FTA scraping and double swabbing methods (p = 0.0051), with FTA paper collecting a two-fold higher amount. Statistical analysis showed no significant difference in DNA yields between the double swabbing and tape lifting techniques (p = 0.21). Based on the DNA concentration required for 1 ng input, 47% of the samples collected using FTA paper would be expected to yield a short tandem repeat (STR) profile compared to 30% and 23% using double swabbing or tape, respectively. Further, 55% and 77% of the samples collected using double swabbing or tape, respectively, did not yield a high enough DNA concentration for the 0.5 ng of DNA input recommended for conventional STR kits and would be expected to result in a partial or no profile compared to 35% of the samples collected using FTA paper. STR analysis was conducted for a subset of the higher concentrated samples to confirm that the DNA collected from the steering wheel was from the driver. 32 samples were selected with DNA amounts of at least 1 ng total DNA (100 pg/μl when concentrated if required). A mixed STR profile was observed for 26 samples (88%) and the last driver was the major DNA contributor for 29 samples (94%). For one sample, the last driver was the minor DNA contributor. A full STR profile of the last driver was observed for

  17. Turbidity threshold sampling: Methods and instrumentation

    Science.gov (United States)

    Rand Eads; Jack Lewis

    2001-01-01

    Traditional methods for determining the frequency of suspended sediment sample collection often rely on measurements, such as water discharge, that are not well correlated to sediment concentration. Stream power is generally not a good predictor of sediment concentration for rivers that transport the bulk of their load as fines, due to the highly variable routing of...

  18. Comparison of oral fluid collection methods for the molecular detection of hepatitis B virus.

    Science.gov (United States)

    Portilho, M M; Mendonça, Acf; Marques, V A; Nabuco, L C; Villela-Nogueira, C A; Ivantes, Cap; Lewis-Ximenez, L L; Lampe, E; Villar, L M

    2017-11-01

    This study aims to compare the efficiency of four oral fluid collection methods (Salivette, FTA Card, spitting and DNA-Sal) to detect HBV DNA by qualitative PCR. Seventy-four individuals (32 HBV reactive and 42 with no HBV markers) donated serum and oral fluid. In-house qualitative PCR to detect HBV was used for both samples and commercial quantitative PCR for serum. HBV DNA was detected in all serum samples from HBV-infected individuals, and it was not detected in control group. HBV DNA from HBV group was detected in 17 samples collected with Salivette device, 16 samples collected by FTA Card device, 16 samples collected from spitting and 13 samples collected by DNA-Sal device. Samples that corresponded to a higher viral load in their paired serum sample could be detected using all oral fluid collection methods, but Salivette collection device yielded the largest numbers of positive samples and had a wide range of viral load that was detected. It was possible to detect HBV DNA using all devices tested, but higher number of positive samples was observed when samples were collected using Salivette device, which shows high concordance to viral load observed in the paired serum samples. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd. All rights reserved.

  19. Solid phase microextraction headspace sampling of chemical warfare agent contaminated samples : method development for GC-MS analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jackson Lepage, C.R.; Hancock, J.R. [Defence Research and Development Canada, Medicine Hat, AB (Canada); Wyatt, H.D.M. [Regina Univ., SK (Canada)

    2004-07-01

    Defence R and D Canada-Suffield (DRDC-Suffield) is responsible for analyzing samples that are suspected to contain chemical warfare agents, either collected by the Canadian Forces or by first-responders in the event of a terrorist attack in Canada. The analytical techniques used to identify the composition of the samples include gas chromatography-mass spectrometry (GC-MS), liquid chromatography-mass spectrometry (LC-MS), Fourier-transform infrared spectroscopy (FT-IR) and nuclear magnetic resonance spectroscopy. GC-MS and LC-MS generally require solvent extraction and reconcentration, thereby increasing sample handling. The authors examined analytical techniques which reduce or eliminate sample manipulation. In particular, this paper presented a screening method based on solid phase microextraction (SPME) headspace sampling and GC-MS analysis for chemical warfare agents such as mustard, sarin, soman, and cyclohexyl methylphosphonofluoridate in contaminated soil samples. SPME is a method which uses small adsorbent polymer coated silica fibers that trap vaporous or liquid analytes for GC or LC analysis. Collection efficiency can be increased by adjusting sampling time and temperature. This method was tested on two real-world samples, one from excavated chemical munitions and the second from a caustic decontamination mixture. 7 refs., 2 tabs., 3 figs.

  20. Trace Elements Analysis of Archeological Brick Samples Collected from Different Historical Placs in Rajshahi Division

    International Nuclear Information System (INIS)

    Begum, Bilkis A.; Biswas, Shapan K.; Matin, Mohammed A.; Hoque, Mohammed M.; Hopke, Philip K.

    2007-01-01

    Twenty-nine brick samples were collected from different temples and palaces, namely Paharpur, Kumarpur, Gaurbari, Puthia and Natore in Rajshahi Division in Bangladesh. The samples were analyzed by X-ray Fluorescence (XRF) method. The elemental data sets have been analyzed in order to find out the general characteristics and any significant differences among the collected samples and identify the origin of these brick samples. Most of the crustal elements have enrichment factor (EF) values close to unity. Only Cu and Pb have high values that may come from painting as these have been collected from temples and palaces.(author)

  1. Portable Automation of Static Chamber Sample Collection for Quantifying Soil Gas Flux

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Morgan P.; Groh, Tyler A.; Parkin, Timothy B.; Williams, Ryan J.; Isenhart, Thomas M.; Hofmockel, Kirsten S.

    2018-01-01

    Quantification of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled is limited by the spacing between chambers and the availability of trained research technicians. An automated system for collecting gas samples from chambers in the field would eliminate the need for personnel to return to the chamber during a flux measurement period and would allow a single technician to sample multiple chambers simultaneously. This study describes Chamber Automated Sampling Equipment (FluxCASE) to collect and store chamber headspace gas samples at assigned time points for the measurement of soil gas flux. The FluxCASE design and operation is described, and the accuracy and precision of the FluxCASE system is evaluated. In laboratory measurements of nitrous oxide (N2O), carbon dioxide (CO2), and methane (CH4) concentrations of a standardized gas mixture, coefficients of variation associated with automated and manual sample collection were comparable, indicating no loss of precision. In the field, soil gas fluxes measured from FluxCASEs were in agreement with manual sampling for both N2O and CO2. Slopes of regression equations were 1.01 for CO2 and 0.97 for N2O. The 95% confidence limits of the slopes of the regression lines included the value of one, indicating no bias. Additionally, an expense analysis found a cost recovery ranging from 0.6 to 2.2 yr. Implementing the FluxCASE system is an alternative to improve the efficiency of the static chamber method for measuring soil gas flux while maintaining the accuracy and precision of manual sampling.

  2. Chemometrics methods for the investigation of methylmercury and total mercury contamination in mollusks samples collected from coastal sites along the Chinese Bohai Sea.

    Science.gov (United States)

    Yawei, Wang; Lina, Liang; Jianbo, Shi; Guibin, Jiang

    2005-06-01

    The development and application of chemometrics methods, principal component analysis (PCA), cluster analysis and correlation analysis for the determination of methylmercury (MeHg) and total mecury (HgT) in gastropod and bivalve species collected from eight coastal sites along the Chinese Bohai Sea are described. HgT is directly determined by atomic fluorescence spectrometry (AFS), while MeHg is measured by a laboratory established high performance liquid chromatography-atomic fluorescence spectrometry system (HPLC-AFS). One-way ANOVA and cluster analysis indicated that the bioaccumulation of Rap to accumulate Hg was significantly (P<0.05) different from other mollusks. Correlation analysis shows that there is linear relationship between MeHg and HgT in mollusks samples collected from coastal sites along the Chinese Bohai Sea, while in mollusks samples collected from Hongqiao market in Beijing City, there is not any linear relationship.

  3. Portable automation of static chamber sample collection for quantifying soil gas flux

    Science.gov (United States)

    The collection of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled in a given time period is limited by the spacing between chambers and the availability of trained research technicians. However, the static chamber method can limit spatial ...

  4. Concordance analysis of methylation biomarkers detection in self-collected and physician-collected samples in cervical neoplasm

    International Nuclear Information System (INIS)

    Chang, Cheng-Chang; Huang, Rui-Lan; Liao, Yu-Ping; Su, Po-Hsuan; Hsu, Yaw-Wen; Wang, Hui-Chen; Tien, Chau-Yang; Yu, Mu-Hsien; Lin, Ya-Wen; Lai, Hung-Cheng

    2015-01-01

    Non-attendance at gynecological clinics is a major limitation of cervical cancer screening and self-collection of samples may improve this situation. Although HPV testing of self-collected vaginal samples is acceptable, the specificity is inadequate. The current focus is increasing self-collection of vaginal samples to minimize clinic visits. In this study, we analyzed the concordance and clinical performance of DNA methylation biomarker (PAX1, SOX1, and ZNF582) detection in self-collected vaginal samples and physician-collected cervical samples for the identification of cervical neoplasm. We enrolled 136 cases with paired methylation data identified from abnormal Pap smears (n = 126) and normal controls (n = 10) regardless of HPV status at gynecological clinics. The study group comprised 37 cervical intraepithelial neoplasm I (CIN1), 23 cervical intraepithelial neoplasm II (CIN2), 16 cervical intraepithelial neoplasm III (CIN3), 30 carcinoma in situ (CIS), 13 squamous cell carcinomas (SCCs) and seven adenocarcinomas (ACs)/adenosquamous carcinomas (ASCs). PAX1, SOX1 and ZNF582 methylation in study samples was assessed by real-time quantitative methylation-specific polymerase chain reaction analysis. We generated methylation index cutoff values for the detection of CIN3+ in physician-collected cervical samples for analysis of the self-collected group. Concordance between the physician-collected and self-collected groups was evaluated by Cohen’s Kappa. Sensitivity, specificity and area under curve (AUC) were calculated for detection of CIN3+ lesions. Finally, we produced an optimal cutoff value with the best sensitivity from the self-collected groups. We generated a methylation index cutoff value from physician-collected samples for detection of CIN3+. There were no significant differences in sensitivity, specificity of PAX1, SOX1 and ZNF582 between the self-collected and physician-collected groups. The methylation status of all three genes in the normal control

  5. Collection and preparation of bottom sediment samples for analysis of radionuclides and trace elements

    International Nuclear Information System (INIS)

    2003-07-01

    The publication is the first in a series of TECDOCs on sampling and sample handling as part of the IAEA support to improve reliability of nuclear analytical techniques (NATs) in Member State laboratories. The purpose of the document is to provide information on the methods for collecting sediments, the equipment used, and the sample preparation techniques for radionuclide and elemental analysis. The most appropriate procedures for defining the strategies and criteria for selecting sampling locations, for sample storage and transportation are also given. Elements of QA/QC and documentation needs for sampling and sediment analysis are discussed. Collection and preparation of stream and river bottom sediments, lake bottom sediments, estuary bottom sediments, and marine (shallow) bottom sediments are covered. The document is intended to be a comprehensive manual for the collection and preparation of bottom sediments as a prerequisite to obtain representative and meaningful results using NATs. Quality assurance and quality control (QA/QC) is emphasized as an important aspect to ensure proper collection, transportation, preservation, and analysis since it forms the basis for interpretation and legislation. Although there are many approaches and methods available for sediment analyses, the scope of the report is limited to sample preparation for (1) analysis of radionuclides (including sediment dating using radionuclides such as Pb-210 and Cs-137) and (2) analysis of trace, minor and major elements using nuclear and related analytical techniques such as NAA, XRF and PIXE

  6. Collection and preparation of bottom sediment samples for analysis of radionuclides and trace elements

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    The publication is the first in a series of TECDOCs on sampling and sample handling as part of the IAEA support to improve reliability of nuclear analytical techniques (NATs) in Member State laboratories. The purpose of the document is to provide information on the methods for collecting sediments, the equipment used, and the sample preparation techniques for radionuclide and elemental analysis. The most appropriate procedures for defining the strategies and criteria for selecting sampling locations, for sample storage and transportation are also given. Elements of QA/QC and documentation needs for sampling and sediment analysis are discussed. Collection and preparation of stream and river bottom sediments, lake bottom sediments, estuary bottom sediments, and marine (shallow) bottom sediments are covered. The document is intended to be a comprehensive manual for the collection and preparation of bottom sediments as a prerequisite to obtain representative and meaningful results using NATs. Quality assurance and quality control (QA/QC) is emphasized as an important aspect to ensure proper collection, transportation, preservation, and analysis since it forms the basis for interpretation and legislation. Although there are many approaches and methods available for sediment analyses, the scope of the report is limited to sample preparation for (1) analysis of radionuclides (including sediment dating using radionuclides such as Pb-210 and Cs-137) and (2) analysis of trace, minor and major elements using nuclear and related analytical techniques such as NAA, XRF and PIXE.

  7. Chapter 12. Sampling and analytical methods

    International Nuclear Information System (INIS)

    Busenberg, E.; Plummer, L.N.; Cook, P.G.; Solomon, D.K.; Han, L.F.; Groening, M.; Oster, H.

    2006-01-01

    When water samples are taken for the analysis of CFCs, regardless of the sampling method used, contamination of samples by contact with atmospheric air (with its 'high' CFC concentrations) is a major concern. This is because groundwaters usually have lower CFC concentrations than those waters which have been exposed to the modern air. Some groundwaters might not contain CFCs and, therefore, are most sensitive to trace contamination by atmospheric air. Thus, extreme precautions are needed to obtain uncontaminated samples when groundwaters, particularly those with older ages, are sampled. It is recommended at the start of any CFC investigation that samples from a CFC-free source be collected and analysed, as a check upon the sampling equipment and methodology. The CFC-free source might be a deep monitoring well or, alternatively, CFC-free water could be carefully prepared in the laboratory. It is especially important that all tubing, pumps and connection that will be used in the sampling campaign be checked in this manner

  8. Sample normalization methods in quantitative metabolomics.

    Science.gov (United States)

    Wu, Yiman; Li, Liang

    2016-01-22

    To reveal metabolomic changes caused by a biological event in quantitative metabolomics, it is critical to use an analytical tool that can perform accurate and precise quantification to examine the true concentration differences of individual metabolites found in different samples. A number of steps are involved in metabolomic analysis including pre-analytical work (e.g., sample collection and storage), analytical work (e.g., sample analysis) and data analysis (e.g., feature extraction and quantification). Each one of them can influence the quantitative results significantly and thus should be performed with great care. Among them, the total sample amount or concentration of metabolites can be significantly different from one sample to another. Thus, it is critical to reduce or eliminate the effect of total sample amount variation on quantification of individual metabolites. In this review, we describe the importance of sample normalization in the analytical workflow with a focus on mass spectrometry (MS)-based platforms, discuss a number of methods recently reported in the literature and comment on their applicability in real world metabolomics applications. Sample normalization has been sometimes ignored in metabolomics, partially due to the lack of a convenient means of performing sample normalization. We show that several methods are now available and sample normalization should be performed in quantitative metabolomics where the analyzed samples have significant variations in total sample amounts. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Survey research with a random digit dial national mobile phone sample in Ghana: Methods and sample quality.

    Science.gov (United States)

    L'Engle, Kelly; Sefa, Eunice; Adimazoya, Edward Akolgo; Yartey, Emmanuel; Lenzi, Rachel; Tarpo, Cindy; Heward-Mills, Nii Lante; Lew, Katherine; Ampeh, Yvonne

    2018-01-01

    Generating a nationally representative sample in low and middle income countries typically requires resource-intensive household level sampling with door-to-door data collection. High mobile phone penetration rates in developing countries provide new opportunities for alternative sampling and data collection methods, but there is limited information about response rates and sample biases in coverage and nonresponse using these methods. We utilized data from an interactive voice response, random-digit dial, national mobile phone survey in Ghana to calculate standardized response rates and assess representativeness of the obtained sample. The survey methodology was piloted in two rounds of data collection. The final survey included 18 demographic, media exposure, and health behavior questions. Call outcomes and response rates were calculated according to the American Association of Public Opinion Research guidelines. Sample characteristics, productivity, and costs per interview were calculated. Representativeness was assessed by comparing data to the Ghana Demographic and Health Survey and the National Population and Housing Census. The survey was fielded during a 27-day period in February-March 2017. There were 9,469 completed interviews and 3,547 partial interviews. Response, cooperation, refusal, and contact rates were 31%, 81%, 7%, and 39% respectively. Twenty-three calls were dialed to produce an eligible contact: nonresponse was substantial due to the automated calling system and dialing of many unassigned or non-working numbers. Younger, urban, better educated, and male respondents were overrepresented in the sample. The innovative mobile phone data collection methodology yielded a large sample in a relatively short period. Response rates were comparable to other surveys, although substantial coverage bias resulted from fewer women, rural, and older residents completing the mobile phone survey in comparison to household surveys. Random digit dialing of mobile

  10. Survey research with a random digit dial national mobile phone sample in Ghana: Methods and sample quality.

    Directory of Open Access Journals (Sweden)

    Kelly L'Engle

    Full Text Available Generating a nationally representative sample in low and middle income countries typically requires resource-intensive household level sampling with door-to-door data collection. High mobile phone penetration rates in developing countries provide new opportunities for alternative sampling and data collection methods, but there is limited information about response rates and sample biases in coverage and nonresponse using these methods. We utilized data from an interactive voice response, random-digit dial, national mobile phone survey in Ghana to calculate standardized response rates and assess representativeness of the obtained sample.The survey methodology was piloted in two rounds of data collection. The final survey included 18 demographic, media exposure, and health behavior questions. Call outcomes and response rates were calculated according to the American Association of Public Opinion Research guidelines. Sample characteristics, productivity, and costs per interview were calculated. Representativeness was assessed by comparing data to the Ghana Demographic and Health Survey and the National Population and Housing Census.The survey was fielded during a 27-day period in February-March 2017. There were 9,469 completed interviews and 3,547 partial interviews. Response, cooperation, refusal, and contact rates were 31%, 81%, 7%, and 39% respectively. Twenty-three calls were dialed to produce an eligible contact: nonresponse was substantial due to the automated calling system and dialing of many unassigned or non-working numbers. Younger, urban, better educated, and male respondents were overrepresented in the sample.The innovative mobile phone data collection methodology yielded a large sample in a relatively short period. Response rates were comparable to other surveys, although substantial coverage bias resulted from fewer women, rural, and older residents completing the mobile phone survey in comparison to household surveys. Random digit

  11. A simple passive method of collecting water vapour for environmental tritium monitoring

    International Nuclear Information System (INIS)

    Iida, T.; Fukuda, H.; Ikebe, Y.; Yokoyama, S.

    1995-01-01

    To investigate the average behaviour of tritium in an atmospheric environment, it is necessary to collect water vapour in air over a long period at numerous locations. For the purpose of the study, the passive method was developed: this is handy, low-priced and could collect water vapour in air without motive power. This paper describes the characteristics of the passive collecting method, the performance of water collection in outdoor air and the measurements of tritium concentrations in water samples collected by the passive method. (author)

  12. Sources of variability in collection and preparation of paint and lead-coating samples.

    Science.gov (United States)

    Harper, S L; Gutknecht, W F

    2001-06-01

    Chronic exposure of children to lead (Pb) can result in permanent physiological impairment. Since surfaces coated with lead-containing paints and varnishes are potential sources of exposure, it is extremely important that reliable methods for sampling and analysis be available. The sources of variability in the collection and preparation of samples were investigated to improve the performance and comparability of methods and to ensure that data generated will be adequate for its intended use. Paint samples of varying sizes (areas and masses) were collected at different locations across a variety of surfaces including metal, plaster, concrete, and wood. A variety of grinding techniques were compared. Manual mortar and pestle grinding for at least 1.5 min and mechanized grinding techniques were found to generate similar homogenous particle size distributions required for aliquots as small as 0.10 g. When 342 samples were evaluated for sample weight loss during mortar and pestle grinding, 4% had 20% or greater loss with a high of 41%. Homogenization and sub-sampling steps were found to be the principal sources of variability related to the size of the sample collected. Analysis of samples from different locations on apparently identical surfaces were found to vary by more than a factor of two both in Pb concentration (mg cm-2 or %) and areal coating density (g cm-2). Analyses of substrates were performed to determine the Pb remaining after coating removal. Levels as high as 1% Pb were found in some substrate samples, corresponding to more than 35 mg cm-2 Pb. In conclusion, these sources of variability must be considered in development and/or application of any sampling and analysis methodologies.

  13. Collection and preparation of samples for Agency's programme of intercalibration methods and procedures for measurement of environmental radioactivity

    International Nuclear Information System (INIS)

    Patel, B.

    1975-12-01

    In the period of 1971-1975 several samples of marine sediment and organisms were collected from the Bombay Harbour Bay as well as from the vicinity of the Tarapur nuclear power station in order to supply the materials for preparing intercalibration samples for radionuclides measurements. All samples collected were freeze-dried and homogenized prior to the dispatch to the Monaco Laboratory, where final homogenization and the homogeneity tests were carried out. Altogether 2 marine organisms and 3 marine sediments were supplied during this period. The materials supplied were proved to be useful to prepare intercalibration samples for radionuclide measurements in the levels for monitoring operations. Based on these materials several intercalibration exercises were successfully conducted. This work thus formed a basis for bringing the better comparability of radionuclide measurements in marine environmental samples in an international scale

  14. Acceptability of self-collected vaginal samples for HPV testing in an ...

    African Journals Online (AJOL)

    Objective: To evaluate the acceptability of self-collected vaginal samples for HPV testing in women living in rural and urban areas of Madagascar. Materials and methods: Participants were recruited in a health care center (urban group) and smaller affiliated dispensaries (rural group). They were invited to perform ...

  15. Archival policies and collections database for the Woods Hole Science Center's marine sediment samples

    Science.gov (United States)

    Buczkowski, Brian J.; Kelsey, Sarah A.

    2007-01-01

    The Woods Hole Science Center of the U.S. Geological Survey (USGS) has been an active member of the Woods Hole research community, Woods Hole, Massachusetts, for over 40 years. In that time there have been many projects that involved the collection of sediment samples conducted by USGS scientists and technicians for the research and study of seabed environments and processes. These samples were collected at sea or near shore and then brought back to the Woods Hole Science Center (WHSC) for analysis. While at the center, samples are stored in ambient temperature, refrigerated and freezing conditions ranging from +2º Celsius to -18º Celsius, depending on the best mode of preparation for the study being conducted or the duration of storage planned for the samples. Recently, storage methods and available storage space have become a major concern at the WHSC. The core and sediment archive program described herein has been initiated to set standards for the management, methods, and duration of sample storage. A need has arisen to maintain organizational consistency and define storage protocol. This handbook serves as a reference and guide to all parties interested in using and accessing the WHSC's sample archive and also defines all the steps necessary to construct and maintain an organized collection of geological samples. It answers many questions as to the way in which the archive functions.

  16. Sampling methods for terrestrial amphibians and reptiles.

    Science.gov (United States)

    Paul Stephen Corn; R. Bruce. Bury

    1990-01-01

    Methods described for sampling amphibians and reptiles in Douglas-fir forests in the Pacific Northwest include pitfall trapping, time-constrained collecting, and surveys of coarse woody debris. The herpetofauna of this region differ in breeding and nonbreeding habitats and vagility, so that no single technique is sufficient for a community study. A combination of...

  17. Chemometrics methods for the investigation of methylmercury and total mercury contamination in mollusks samples collected from coastal sites along the Chinese Bohai Sea

    International Nuclear Information System (INIS)

    Wang Yawei; Liang Lina; Shi Jianbo; Jiang Guibin

    2005-01-01

    The development and application of chemometrics methods, principal component analysis (PCA), cluster analysis and correlation analysis for the determination of methylmercury (MeHg) and total mercury (HgT) in gastropod and bivalve species collected from eight coastal sites along the Chinese Bohai Sea are described. HgT is directly determined by atomic fluorescence spectrometry (AFS), while MeHg is measured by a laboratory established high performance liquid chromatography-atomic fluorescence spectrometry system (HPLC-AFS). One-way ANOVA and cluster analysis indicated that the bioaccumulation of Rap to accumulate Hg was significantly (P<0.05) different from other mollusks. Correlation analysis shows that there is linear relationship between MeHg and HgT in mollusks samples collected from coastal sites along the Chinese Bohai Sea, while in mollusks samples collected from Hongqiao market in Beijing City, there is not any linear relationship. - Rapana venosa might be used as a potential biomonitor for Hg pollution in the Bohai Sea, China

  18. A New Method for Quick and Easy Hemolymph Collection from Apidae Adults.

    Directory of Open Access Journals (Sweden)

    Grzegorz Borsuk

    Full Text Available Bio-analysis of insects is increasingly dependent on highly sensitive methods that require high quality biological material, such as hemolymph. However, it is difficult to collect fresh and uncontaminated hemolymph from adult bees since they are very active and have the potential to sting, and because hemolymph is rapidly melanized. Here we aimed to develop and test a quick and easy method for sterile and contamination-free hemolymph sampling from adult Apidae. Our novel antennae method for hemolymph sampling (AMHS, entailed the detachment of an antenna, followed by application of delicate pressure to the bee's abdomen. This resulted in the appearance of a drop of hemolymph at the base of the detached antenna, which was then aspirated using an automatic pipetter. Larger insect size corresponded to easier and faster hemolymph sampling, and to a greater sample volume. We obtained 80-100 μL of sterile non-melanized hemolymph in 1 minute from one Bombus terrestris worker, in 6 minutes from 10 Apis mellifera workers, and in 15 minutes from 18 Apis cerana workers (+/-0.5 minutes. Compared to the most popular method of hemolymph collection, in which hemolymph is sampled by puncturing the dorsal sinus of the thorax with a capillary (TCHS, significantly fewer bees were required to collect 80-100 μL hemolymph using our novel AMHS method. Moreover, the time required for hemolymph collection was significantly shorter using the AMHS compared to the TCHS, which protects the acquired hemolymph against melanization, thus providing the highest quality material for biological analysis.

  19. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF SOIL SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.20)

    Science.gov (United States)

    This SOP describes the method for collecting soil samples from the child's outdoor play area to measure for persistent organic pollutants. Soil samples are collected by scraping up the top 0.5 cm of soil in a 0.095 m2 (1 ft2) area in the middle of the child's play area.

  20. Water sample-collection and distribution system

    Science.gov (United States)

    Brooks, R. R.

    1978-01-01

    Collection and distribution system samples water from six designated stations, filtered if desired, and delivers it to various analytical sensors. System may be controlled by Water Monitoring Data Acquisition System or operated manually.

  1. Evaluation of environmental sampling methods for detection of Salmonella enterica in a large animal veterinary hospital.

    Science.gov (United States)

    Goeman, Valerie R; Tinkler, Stacy H; Hammac, G Kenitra; Ruple, Audrey

    2018-04-01

    Environmental surveillance for Salmonella enterica can be used for early detection of contamination; thus routine sampling is an integral component of infection control programs in hospital environments. At the Purdue University Veterinary Teaching Hospital (PUVTH), the technique regularly employed in the large animal hospital for sample collection uses sterile gauze sponges for environmental sampling, which has proven labor-intensive and time-consuming. Alternative sampling methods use Swiffer brand electrostatic wipes for environmental sample collection, which are reportedly effective and efficient. It was hypothesized that use of Swiffer wipes for sample collection would be more efficient and less costly than the use of gauze sponges. A head-to-head comparison between the 2 sampling methods was conducted in the PUVTH large animal hospital and relative agreement, cost-effectiveness, and sampling efficiency were compared. There was fair agreement in culture results between the 2 sampling methods, but Swiffer wipes required less time and less physical effort to collect samples and were more cost-effective.

  2. Application of bar codes to the automation of analytical sample data collection

    International Nuclear Information System (INIS)

    Jurgensen, H.A.

    1986-01-01

    The Health Protection Department at the Savannah River Plant collects 500 urine samples per day for tritium analyses. Prior to automation, all sample information was compiled manually. Bar code technology was chosen for automating this program because it provides a more accurate, efficient, and inexpensive method for data entry. The system has three major functions: sample labeling is accomplished at remote bar code label stations composed of an Intermec 8220 (Intermec Corp.) interfaced to an IBM-PC, data collection is done on a central VAX 11/730 (Digital Equipment Corp.). Bar code readers are used to log-in samples to be analyzed on liquid scintillation counters. The VAX 11/730 processes the data and generates reports, data storage is on the VAX 11/730 and backed up on the plant's central computer. A brief description of several other bar code applications at the Savannah River Plant is also presented

  3. A novel method for fission product noble gas sampling

    International Nuclear Information System (INIS)

    Jain, S.K.; Prakash, Vivek; Singh, G.K.; Vinay, Kr.; Awsthi, A.; Bihari, K.; Joyson, R.; Manu, K.; Gupta, Ashok

    2008-01-01

    Noble gases occur to some extent in the Earth's atmosphere, but the concentrations of all but argon are exceedingly low. Argon is plentiful, constituting almost 1 % of the air. Fission Product Noble Gases (FPNG) are produced by nuclear fission and large parts of FPNG is produced in Nuclear reactions. FPNG are b-j emitters and contributing significantly in public dose. During normal operation of reactor release of FPNG is negligible but its release increases in case of fuel failure. Xenon, a member of FPNG family helps in identification of fuel failure and its extent in PHWRs. Due to above reasons it becomes necessary to assess the FPNG release during operation of NPPs. Presently used methodology of assessment of FPNG, at almost all power stations is Computer based gamma ray spectrometry. This provides fission product Noble gases nuclide identification through peak search of spectra. The air sample for the same is collected by grab sampling method, which has inherent disadvantages. An alternate method was developed at Rajasthan Atomic Power Station (RAPS) - 3 and 4 for assessment of FPNG, which uses adsorption phenomena for collection of air samples. This report presents details of sampling method for FPNG and noble gases in different systems of Nuclear Power Plant. (author)

  4. Characterization Of Core Sample Collected From The Saltstone Disposal Facility

    International Nuclear Information System (INIS)

    Cozzi, A.; Duncan, A.

    2010-01-01

    During the month of September 2008, grout core samples were collected from the Saltstone Disposal Facility, Vault 4, cell E. This grout was placed during processing campaigns in December 2007 from Deliquification, Dissolution and Adjustment Batch 2 salt solution. The 4QCY07 Waste Acceptance Criteria sample collected on 11/16/07 represents the salt solution in the core samples. Core samples were retrieved to initiate the historical database of properties of emplaced Saltstone and to demonstrate the correlation between field collected and laboratory prepared samples. Three samples were collected from three different locations. Samples were collected using a two-inch diameter concrete coring bit. In April 2009, the core samples were removed from the evacuated sample container, inspected, transferred to PVC containers, and backfilled with nitrogen. Samples furthest from the wall were the most intact cylindrically shaped cored samples. The shade of the core samples darkened as the depth of coring increased. Based on the visual inspection, sample 3-3 was selected for all subsequent analysis. The density and porosity of the Vault 4 core sample, 1.90 g/cm 3 and 59.90% respectively, were comparable to values achieved for laboratory prepared samples. X-ray diffraction analysis identified phases consistent with the expectations for hydrated Saltstone. Microscopic analysis revealed morphology features characteristic of cementitious materials with fly ash and calcium silicate hydrate gel. When taken together, the results of the density, porosity, x-ray diffraction analysis and microscopic analysis support the conclusion that the Vault 4, Cell E core sample is representative of the expected waste form.

  5. An Improved Method for Collection of Cerebrospinal Fluid from Anesthetized Mice

    DEFF Research Database (Denmark)

    Lim, Nastasia K-H; Moestrup, Visse Theresia Skov; Zhang, Xiao

    2017-01-01

    a technique that improves on current methods of collection to minimize contamination from blood and allow for the abundant collection of CSF (on average 10-15 µL can be collected). This technique can be used with other dissection methods for tissue collection from mice, as it does not impact any tissues......The cerebrospinal fluid (CSF) is a valuable body fluid for analysis in neuroscience research. It is one of the fluids in closest contact with the central nervous system and thus, can be used to analyze the diseased state of the brain or spinal cord without directly accessing these tissues. However......, in mice it is difficult to obtain from the cisterna magna due to its closeness to blood vessels, which often contaminate samples. The area for CSF collection in mice is also difficult to dissect to and often only small samples are obtained (maximum of 5-7 µL or less). This protocol describes in detail...

  6. Scientific guidelines for preservation of samples collected from Mars

    International Nuclear Information System (INIS)

    Gooding, J.L.

    1990-04-01

    The maximum scientific value of Martian geologic and atmospheric samples is retained when the samples are preserved in the conditions that applied prior to their collection. Any sample degradation equates to loss of information. Based on detailed review of pertinent scientific literature, and advice from experts in planetary sample analysis, number values are recommended for key parameters in the environmental control of collected samples with respect to material contamination, temperature, head-space gas pressure, ionizing radiation, magnetic fields, and acceleration/shock. Parametric values recommended for the most sensitive geologic samples should also be adequate to preserve any biogenic compounds or exobiological relics

  7. Collection and preparation of marine samples for radionuclide analysis

    International Nuclear Information System (INIS)

    Holm, E.

    1997-01-01

    The ultimate goal of research in radioecology is to be able to predict the pathways of radioactive material in the environment and hence estimate possible doses to the population in various regions. Knowledge of levels of contamination are necessary to maintain control of operations of nuclear facilities. Correct methods of sample collection, handling and preparation are among the most important parts for a correct assessment. On basis of the final results of radionuclide concentrations, scientific, medical and political decisions are taken. (author)

  8. Methods of developing core collections based on the predicted genotypic value of rice ( Oryza sativa L.).

    Science.gov (United States)

    Li, C T; Shi, C H; Wu, J G; Xu, H M; Zhang, H Z; Ren, Y L

    2004-04-01

    The selection of an appropriate sampling strategy and a clustering method is important in the construction of core collections based on predicted genotypic values in order to retain the greatest degree of genetic diversity of the initial collection. In this study, methods of developing rice core collections were evaluated based on the predicted genotypic values for 992 rice varieties with 13 quantitative traits. The genotypic values of the traits were predicted by the adjusted unbiased prediction (AUP) method. Based on the predicted genotypic values, Mahalanobis distances were calculated and employed to measure the genetic similarities among the rice varieties. Six hierarchical clustering methods, including the single linkage, median linkage, centroid, unweighted pair-group average, weighted pair-group average and flexible-beta methods, were combined with random, preferred and deviation sampling to develop 18 core collections of rice germplasm. The results show that the deviation sampling strategy in combination with the unweighted pair-group average method of hierarchical clustering retains the greatest degree of genetic diversities of the initial collection. The core collections sampled using predicted genotypic values had more genetic diversity than those based on phenotypic values.

  9. Sampling of temporal networks: Methods and biases

    Science.gov (United States)

    Rocha, Luis E. C.; Masuda, Naoki; Holme, Petter

    2017-11-01

    Temporal networks have been increasingly used to model a diversity of systems that evolve in time; for example, human contact structures over which dynamic processes such as epidemics take place. A fundamental aspect of real-life networks is that they are sampled within temporal and spatial frames. Furthermore, one might wish to subsample networks to reduce their size for better visualization or to perform computationally intensive simulations. The sampling method may affect the network structure and thus caution is necessary to generalize results based on samples. In this paper, we study four sampling strategies applied to a variety of real-life temporal networks. We quantify the biases generated by each sampling strategy on a number of relevant statistics such as link activity, temporal paths and epidemic spread. We find that some biases are common in a variety of networks and statistics, but one strategy, uniform sampling of nodes, shows improved performance in most scenarios. Given the particularities of temporal network data and the variety of network structures, we recommend that the choice of sampling methods be problem oriented to minimize the potential biases for the specific research questions on hand. Our results help researchers to better design network data collection protocols and to understand the limitations of sampled temporal network data.

  10. Surface Sampling Collection and Culture Methods for Escherichia coli in Household Environments with High Fecal Contamination.

    Science.gov (United States)

    Exum, Natalie G; Kosek, Margaret N; Davis, Meghan F; Schwab, Kellogg J

    2017-08-22

    Empiric quantification of environmental fecal contamination is an important step toward understanding the impact that water, sanitation, and hygiene interventions have on reducing enteric infections. There is a need to standardize the methods used for surface sampling in field studies that examine fecal contamination in low-income settings. The dry cloth method presented in this manuscript improves upon the more commonly used swabbing technique that has been shown in the literature to have a low sampling efficiency. The recovery efficiency of a dry electrostatic cloth sampling method was evaluated using Escherichia coli and then applied to household surfaces in Iquitos, Peru, where there is high fecal contamination and enteric infection. Side-by-side measurements were taken from various floor locations within a household at the same time over a three-month period to compare for consistency of quantification of E. coli bacteria. The dry cloth sampling method in the laboratory setting showed 105% (95% Confidence Interval: 98%, 113%) E. coli recovery efficiency off of the cloths. The field application demonstrated strong agreement of side-by-side results (Pearson correlation coefficient for dirt surfaces was 0.83 ( p samples (Pearson (0.53, p method can be utilized in households with high bacterial loads using either continuous (quantitative) or categorical (semi-quantitative) data. The standardization of this low-cost, dry electrostatic cloth sampling method can be used to measure differences between households in intervention and non-intervention arms of randomized trials.

  11. Fieldwork and catalogue of samples collected in Polan, September 1995

    Energy Technology Data Exchange (ETDEWEB)

    Poulsen, N.; Drewniak, A.; Glowniak, E.; Ineson, J.; Matyja, B.A.; Merta, T.; Wierzbowski, A.

    1995-12-31

    This report lists the collection of samples taken during the field work of the EFP-95 Project, named `The Polish Middle to Late Jurassic Epicratonic basin, stratigraphy, facies and basin history` (short title: Jurrasic basin study, Poland) in Poland, August 7-20, 1995. The samples were collected for palynological studies, and/or sedimentaological studies, and/or source rock studies, and/or reservoir rock characteristics. Prepared samples (slides etc.) are stored in the collections of the GEUS, and remaining rock-material at the store of the GEUS. Field work with collection of samples for palynological studies has been carried earlier in 1988 and at the Oxfordian and Kimmeridgian Joint Working Groups Meeting 1992. (au)

  12. The CUPID (Cultural and Psychosocial Influences on Disability study: methods of data collection and characteristics of study sample.

    Directory of Open Access Journals (Sweden)

    David Coggon

    Full Text Available The CUPID (Cultural and Psychosocial Influences on Disability study was established to explore the hypothesis that common musculoskeletal disorders (MSDs and associated disability are importantly influenced by culturally determined health beliefs and expectations. This paper describes the methods of data collection and various characteristics of the study sample.A standardised questionnaire covering musculoskeletal symptoms, disability and potential risk factors, was used to collect information from 47 samples of nurses, office workers, and other (mostly manual workers in 18 countries from six continents. In addition, local investigators provided data on economic aspects of employment for each occupational group. Participation exceeded 80% in 33 of the 47 occupational groups, and after pre-specified exclusions, analysis was based on 12,426 subjects (92 to 1018 per occupational group. As expected, there was high usage of computer keyboards by office workers, while nurses had the highest prevalence of heavy manual lifting in all but one country. There was substantial heterogeneity between occupational groups in economic and psychosocial aspects of work; three- to five-fold variation in awareness of someone outside work with musculoskeletal pain; and more than ten-fold variation in the prevalence of adverse health beliefs about back and arm pain, and in awareness of terms such as "repetitive strain injury" (RSI.The large differences in psychosocial risk factors (including knowledge and beliefs about MSDs between occupational groups should allow the study hypothesis to be addressed effectively.

  13. Sampling methods for the study of pneumococcal carriage: a systematic review.

    Science.gov (United States)

    Gladstone, R A; Jefferies, J M; Faust, S N; Clarke, S C

    2012-11-06

    Streptococcus pneumoniae is an important pathogen worldwide. Accurate sampling of S. pneumoniae carriage is central to surveillance studies before and following conjugate vaccination programmes to combat pneumococcal disease. Any bias introduced during sampling will affect downstream recovery and typing. Many variables exist for the method of collection and initial processing, which can make inter-laboratory or international comparisons of data complex. In February 2003, a World Health Organisation working group published a standard method for the detection of pneumococcal carriage for vaccine trials to reduce or eliminate variability. We sought to describe the variables associated with the sampling of S. pneumoniae from collection to storage in the context of the methods recommended by the WHO and those used in pneumococcal carriage studies since its publication. A search of published literature in the online PubMed database was performed on the 1st June 2012, to identify published studies that collected pneumococcal carriage isolates, conducted after the publication of the WHO standard method. After undertaking a systematic analysis of the literature, we show that a number of differences in pneumococcal sampling protocol continue to exist between studies since the WHO publication. The majority of studies sample from the nasopharynx, but the choice of swab and swab transport media is more variable between studies. At present there is insufficient experimental data that supports the optimal sensitivity of any standard method. This may have contributed to incomplete adoption of the primary stages of the WHO detection protocol, alongside pragmatic or logistical issues associated with study design. Consequently studies may not provide a true estimate of pneumococcal carriage. Optimal sampling of carriage could lead to improvements in downstream analysis and the evaluation of pneumococcal vaccine impact and extrapolation to pneumococcal disease control therefore

  14. Sample collection of virulent and non-virulent B. anthracis and Y. pestis for bioforensics analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hong-geller, Elizabeth [Los Alamos National Laboratory; Valdez, Yolanda E [Los Alamos National Laboratory; Shou, Yulin [Los Alamos National Laboratory; Yoshida, Thomas M [Los Alamos National Laboratory; Marrone, Babetta L [Los Alamos National Laboratory; Dunbar, John [Los Alamos National Laboratory

    2009-01-01

    Validated sample collection methods are needed for recovery of microbial evidence in the event of accidental or intentional release of biological agents into the environment. To address this need, we evaluated the sample recovery efficiencies of two collection methods -- swabs and wipes -- for both non-virulent and virulent strains of B. anthracis and Y. pestis from four types of non-porous surfaces: two hydrophilic surfaces, stainless steel and glass, and two hydrophobic surfaces, vinyl and plastic. Sample recovery was quantified using Real-time qPCR to assay for intact DNA signatures. We found no consistent difference in collection efficiency between swabs or wipes. Furthermore, collection efficiency was more surface-dependent for virulent strains than non-virulent strains. For the two non-virulent strains, B. anthracis Sterne and Y. pestis A1122, collection efficiency was approximately 100% and 1 %, respectively, from all four surfaces. In contrast, recovery of B. anthracis Ames spores and Y. pestis C092 from vinyl and plastic was generally lower compared to collection from glass or stainless steel, suggesting that surface hydrophobicity may playa role in the strength of pathogen adhesion. The surface-dependent collection efficiencies observed with the virulent strains may arise from strain-specific expression of capsular material or other cell surface receptors that alter cell adhesion to specific surfaces. These findings contribute to validation of standard bioforensics procedures and emphasize the importance of specific strain and surface interactions in pathogen detection.

  15. Sample collection: an overview of the Hydrogeochemical and Stream Sediment Reconnaissance Program

    International Nuclear Information System (INIS)

    Bolivar, S.L.

    1979-01-01

    A Hydrogeochemical and Stream Sediment Reconnaissance (HSSR) for uranium is currently being conducted throughout the conterminous United States and Alaska. The HSSR is part of the National Uranium Resource Evaluation sponsored by the US Department of Energy. This ambitious geochemical reconnaissance program is conducted by four national laboratories: Los Alamos Scientific Laboratory, Lawrence Livermore Laboratory, Oak Ridge Gaseous Diffusion Plant, and Savannah River Laboratory. The program is based on an extensive review of world literature, reconnaissance work done in other countries, and pilot studies conducted by each laboratory. Sample-collection methods and sample density are determined to optimize the probability of detecting potential uranium mineralization. To achieve this aim, each laboratory has developed independent standardized field collection procedures that are designed for its section of the country. Field parameters such as pH, conductivity, climate, geography, and geology are recorded at each site. Most samples are collected at densities of one sample site per 10 to 23 km 2 . The HSSR program has helped to improve existing hydrogeochemical reconnaissance exploration techniques. In addition to providing industry with data that may help to identify potential uranium districts and to extend known uranium provinces, the HSSR also provides multi-element analytical data, which can be used in water quality, soil, sediment, environmental, and base-metal exploration studies

  16. Assessment of reagent effectiveness and preservation methods for equine faecal samples

    Directory of Open Access Journals (Sweden)

    Eva Vavrouchova

    2015-03-01

    Full Text Available The aim of our study was to identify the most suitable flotation solution and effective preservation method for the examination of equine faeces samples using the FLOTAC technique. Samples from naturally infected horses were transported to the laboratory andanalysed accordingly. The sample from each horse was homogenized and divided into four parts: one was frozen, another two were preserved in different reagents such as sodium acetate-acetic-acid–formalin (SAF or 5% formalin.The last part was examined as a fresh sample in three different flotation solutions (Sheather´s solution, sodium chloride and sodium nitrate solution, all with a specific gravity 1.200. The preserved samples were examined in the period from 14 to21days after collection. According to our results, the sucrose solution was the most suitable flotation solution for fresh samples (small strongyle egg per gram was 706 compared to 360 in sodium chlorid and 507 in sodium nitrate and the sodium nitrate solution was the most efficient for the preserved samples (egg per gram was 382 compared to 295 in salt solution and 305 in sucrose solution. Freezing appears to be the most effective method of sample preservation, resulting in minimal damage to fragile strongyle eggs and therefore it is the most simple and effective preservation method for the examination of large numbers of faecal samples without the necessity of examining them all within 48 hours of collection. Deep freezing as a preservation method for equine faeces samples has not, according to our knowledge, been yet published.

  17. Effect of milk sample delivery methods and arrival conditions on bacterial contamination rates.

    Science.gov (United States)

    Dinsmore, R P; English, P B; Matthews, J C; Sears, P M

    1990-07-01

    A cross sectional study was performed of factors believed to contribute to the contamination of bovine milk sample cultures submitted to the Ithaca Regional Laboratory of the Quality Milk Promotion Services/New York State Mastitis Control. Of 871 samples entered in the study, 137 (15.7%) were contaminated. There were interactions between the sample source (veterinarian vs dairyman), delivery method, and time between sample collection and arrival at the laboratory. If only those samples collected and hand delivered by the dairyman within 1 day of collection were compared to a like subset of samples collected and hand delivered by veterinarians, no statistically significant differences in milk sample contamination rate (MSCR) were found. Samples were delivered to the laboratory by hand, US Postal Service, United Parcel Service, via the New York State College of Veterinary Medicine Diagnostic Laboratory, or Northeast Dairy Herd Improvement Association Courier. The MSCR was only 7.6% for hand delivered samples, while 26% of Postal Service samples were contaminated. These rates differed significantly from other delivery methods (P less than 0.0001). The USPS samples arrived a longer time after sampling than did samples sent by other routes, and time had a significant effect on MSCR (0 to 1 day, 8.9%; greater than 1 day, 25.9%; P less than 0.01). Samples packaged with ice packs sent by routes other than the Postal Service had a lower MSCR than those not packaged with ice packs, but ice packs did not reduce the MSCR for samples sent by the Postal Service.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Sample preparation method for ICP-MS measurement of 99Tc in a large amount of environmental samples

    International Nuclear Information System (INIS)

    Kondo, M.; Seki, R.

    2002-01-01

    Sample preparation for measurement of 99 Tc in a large amount of soil and water samples by ICP-MS has been developed using 95m Tc as a yield tracer. This method is based on the conventional method for a small amount of soil samples using incineration, acid digestion, extraction chromatography (TEVA resin) and ICP-MS measurement. Preliminary concentration of Tc has been introduced by co-precipitation with ferric oxide. The matrix materials in a large amount of samples were more sufficiently removed with keeping the high recovery of Tc than previous method. The recovery of Tc was 70-80% for 100 g soil samples and 60-70% for 500 g of soil and 500 L of water samples. The detection limit of this method was evaluated as 0.054 mBq/kg in 500 g soil and 0.032 μBq/L in 500 L water. The determined value of 99 Tc in the IAEA-375 (soil sample collected near the Chernobyl Nuclear Reactor) was 0.25 ± 0.02 Bq/kg. (author)

  19. Curating NASA's Past, Present, and Future Astromaterial Sample Collections

    Science.gov (United States)

    Zeigler, R. A.; Allton, J. H.; Evans, C. A.; Fries, M. D.; McCubbin, F. M.; Nakamura-Messenger, K.; Righter, K.; Zolensky, M.; Stansbery, E. K.

    2016-01-01

    The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC curation) is responsible for curating all of NASA's extraterrestrial samples. JSC presently curates 9 different astromaterials collections in seven different clean-room suites: (1) Apollo Samples (ISO (International Standards Organization) class 6 + 7); (2) Antarctic Meteorites (ISO 6 + 7); (3) Cosmic Dust Particles (ISO 5); (4) Microparticle Impact Collection (ISO 7; formerly called Space-Exposed Hardware); (5) Genesis Solar Wind Atoms (ISO 4); (6) Stardust Comet Particles (ISO 5); (7) Stardust Interstellar Particles (ISO 5); (8) Hayabusa Asteroid Particles (ISO 5); (9) OSIRIS-REx Spacecraft Coupons and Witness Plates (ISO 7). Additional cleanrooms are currently being planned to house samples from two new collections, Hayabusa 2 (2021) and OSIRIS-REx (2023). In addition to the labs that house the samples, we maintain a wide variety of infra-structure facilities required to support the clean rooms: HEPA-filtered air-handling systems, ultrapure dry gaseous nitrogen systems, an ultrapure water system, and cleaning facilities to provide clean tools and equipment for the labs. We also have sample preparation facilities for making thin sections, microtome sections, and even focused ion-beam sections. We routinely monitor the cleanliness of our clean rooms and infrastructure systems, including measurements of inorganic or organic contamination, weekly airborne particle counts, compositional and isotopic monitoring of liquid N2 deliveries, and daily UPW system monitoring. In addition to the physical maintenance of the samples, we track within our databases the current and ever changing characteristics (weight, location, etc.) of more than 250,000 individually numbered samples across our various collections, as well as more than 100,000 images, and countless "analog" records that record the sample processing records of each individual sample. JSC Curation is co-located with JSC

  20. A Systematic Review of Published Respondent-Driven Sampling Surveys Collecting Behavioral and Biologic Data.

    Science.gov (United States)

    Johnston, Lisa G; Hakim, Avi J; Dittrich, Samantha; Burnett, Janet; Kim, Evelyn; White, Richard G

    2016-08-01

    Reporting key details of respondent-driven sampling (RDS) survey implementation and analysis is essential for assessing the quality of RDS surveys. RDS is both a recruitment and analytic method and, as such, it is important to adequately describe both aspects in publications. We extracted data from peer-reviewed literature published through September, 2013 that reported collected biological specimens using RDS. We identified 151 eligible peer-reviewed articles describing 222 surveys conducted in seven regions throughout the world. Most published surveys reported basic implementation information such as survey city, country, year, population sampled, interview method, and final sample size. However, many surveys did not report essential methodological and analytical information for assessing RDS survey quality, including number of recruitment sites, seeds at start and end, maximum number of waves, and whether data were adjusted for network size. Understanding the quality of data collection and analysis in RDS is useful for effectively planning public health service delivery and funding priorities.

  1. Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure using a laser sensor

    Science.gov (United States)

    Van Berkel, Gary J [Clinton, TN; Kertesz, Vilmos [Knoxville, TN

    2012-02-21

    A system and method utilizes distance-measuring equipment including a laser sensor for controlling the collection instrument-to-surface distance during a sample collection process for use, for example, with mass spectrometric detection. The laser sensor is arranged in a fixed positional relationship with the collection instrument, and a signal is generated by way of the laser sensor which corresponds to the actual distance between the laser sensor and the surface. The actual distance between the laser sensor and the surface is compared to a target distance between the laser sensor and the surface when the collection instrument is arranged at a desired distance from the surface for sample collecting purposes, and adjustments are made, if necessary, so that the actual distance approaches the target distance.

  2. A comparison of human papillomavirus testing of clinician-collected and self-collected samples during follow-up after screen-and-treat.

    Science.gov (United States)

    Taylor, Sylvia; Wang, Chunhui; Wright, Thomas C; Denny, Lynette; Kuhn, Louise

    2011-08-15

    Screen-and-treat cervical cancer prevention programs based on high-risk human papillomavirus (HPV) testing and cryotherapy have been shown to be effective in resource-limited settings. However, because cryotherapy is not 100% effective, follow-up is needed after treatment to detect post-treatment failures. We compared the test performances of high-risk HPV testing (Hybrid Capture 2) using self-collected and clinician-collected samples as well as cervical cytology for identifying cervical intraepithelial neoplasia grades 2 or 3 or invasive cervical cancer (CIN2+) among women who did (n=812) and did not (n=1858) undergo cryotherapy in a South African screen-and-treat trial. At 6 months after enrolment (and after cryotherapy, if performed), women were tested using all three screening methods and then underwent colposcopy/biopsy. A predefined subset of women (n=1,455) had extended follow-up with colposcopy/biopsy at 12 months. A total of 33 and 91 cases of CIN2+ were detected among treated and untreated women, respectively. The sensitivity of HPV testing using clinician-collected samples and cervical cytology did not differ by treatment status. HPV testing of clinician-collected samples detected the most cases of CIN2+ among both treated (85%) and untreated (91%) women (p=0.31). Cytology (at a cutoff of atypical squamous cells of undetermined significance or greater) detected 76% of cases among both treated and untreated women. However, the sensitivity of HPV testing using self-collected samples was significantly lower among treated versus untreated women (55% vs. 78%, p=0.01). HPV testing using self-collected vaginal specimens may be useful in primary screening but performs poorly for detecting post-treatment failures. Copyright © 2010 UICC.

  3. Toward cost-efficient sampling methods

    Science.gov (United States)

    Luo, Peng; Li, Yongli; Wu, Chong; Zhang, Guijie

    2015-09-01

    The sampling method has been paid much attention in the field of complex network in general and statistical physics in particular. This paper proposes two new sampling methods based on the idea that a small part of vertices with high node degree could possess the most structure information of a complex network. The two proposed sampling methods are efficient in sampling high degree nodes so that they would be useful even if the sampling rate is low, which means cost-efficient. The first new sampling method is developed on the basis of the widely used stratified random sampling (SRS) method and the second one improves the famous snowball sampling (SBS) method. In order to demonstrate the validity and accuracy of two new sampling methods, we compare them with the existing sampling methods in three commonly used simulation networks that are scale-free network, random network, small-world network, and also in two real networks. The experimental results illustrate that the two proposed sampling methods perform much better than the existing sampling methods in terms of achieving the true network structure characteristics reflected by clustering coefficient, Bonacich centrality and average path length, especially when the sampling rate is low.

  4. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1994-04-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Laboratory Management Division of the DOE. Methods are prepared for entry into DOE Methods as chapter editors, together with DOE and other participants in this program, identify analytical and sampling method needs. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types. open-quotes Draftclose quotes or open-quotes Verified.close quotes. open-quotes Draftclose quotes methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. open-quotes Verifiedclose quotes methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations

  5. Towards Cost-efficient Sampling Methods

    OpenAIRE

    Peng, Luo; Yongli, Li; Chong, Wu

    2014-01-01

    The sampling method has been paid much attention in the field of complex network in general and statistical physics in particular. This paper presents two new sampling methods based on the perspective that a small part of vertices with high node degree can possess the most structure information of a network. The two proposed sampling methods are efficient in sampling the nodes with high degree. The first new sampling method is improved on the basis of the stratified random sampling method and...

  6. Short Communication: A Simple Method for Performing Worm-Egg Counts on Sodium Acetate Formaldehyde-Preserved Samples

    Directory of Open Access Journals (Sweden)

    Wayne Melrose

    2012-01-01

    Full Text Available The Kato Katz method is the most common way of performing worm-egg counts on human faecal samples, but it must be done in the field using freshly collected samples. This makes it difficult to use in remote, poorly accessible situations. This paper describes a simple method for egg counts on preserved samples collected in the field and sent to a central location for further processing.

  7. Methods for Sampling and Measurement of Compressed Air Contaminants

    Energy Technology Data Exchange (ETDEWEB)

    Stroem, L

    1976-10-15

    In order to improve the technique for measuring oil and water entrained in a compressed air stream, a laboratory study has been made of some methods for sampling and measurement. For this purpose water or oil as artificial contaminants were injected in thin streams into a test loop, carrying dry compressed air. Sampling was performed in a vertical run, down-stream of the injection point. Wall attached liquid, coarse droplet flow, and fine droplet flow were sampled separately. The results were compared with two-phase flow theory and direct observation of liquid behaviour. In a study of sample transport through narrow tubes, it was observed that, below a certain liquid loading, the sample did not move, the liquid remaining stationary on the tubing wall. The basic analysis of the collected samples was made by gravimetric methods. Adsorption tubes were used with success to measure water vapour. A humidity meter with a sensor of the aluminium oxide type was found to be unreliable. Oil could be measured selectively by a flame ionization detector, the sample being pretreated in an evaporation- condensation unit

  8. Methods for Sampling and Measurement of Compressed Air Contaminants

    International Nuclear Information System (INIS)

    Stroem, L.

    1976-10-01

    In order to improve the technique for measuring oil and water entrained in a compressed air stream, a laboratory study has been made of some methods for sampling and measurement. For this purpose water or oil as artificial contaminants were injected in thin streams into a test loop, carrying dry compressed air. Sampling was performed in a vertical run, down-stream of the injection point. Wall attached liquid, coarse droplet flow, and fine droplet flow were sampled separately. The results were compared with two-phase flow theory and direct observation of liquid behaviour. In a study of sample transport through narrow tubes, it was observed that, below a certain liquid loading, the sample did not move, the liquid remaining stationary on the tubing wall. The basic analysis of the collected samples was made by gravimetric methods. Adsorption tubes were used with success to measure water vapour. A humidity meter with a sensor of the aluminium oxide type was found to be unreliable. Oil could be measured selectively by a flame ionization detector, the sample being pretreated in an evaporation- condensation unit

  9. Aspergillus, Penicillium and Talaromyces isolated from house dust samples collected around the world

    NARCIS (Netherlands)

    Visagie, C M; Hirooka, Y; Tanney, J B; Whitfield, E; Mwange, K; Meijer, M; Amend, A S; Seifert, K A; Samson, R A

    As part of a worldwide survey of the indoor mycobiota, dust was collected from nine countries. Analyses of dust samples included the culture-dependent dilution-to-extinction method and the culture-independent 454-pyrosequencing. Of the 7 904 isolates, 2 717 isolates were identified as belonging to

  10. A New Method for Noninvasive Genetic Sampling of Saliva in Ecological Research.

    Directory of Open Access Journals (Sweden)

    Diana Lobo

    Full Text Available Noninvasive samples for genetic analyses have become essential to address ecological questions. Popular noninvasive samples such as faeces contain degraded DNA which may compromise genotyping success. Saliva is an excellent alternative DNA source but scarcity of suitable collection methods makes its use anecdotal in field ecological studies. We develop a noninvasive method of collection that combines baits and porous materials able to capture saliva. We report its potential in optimal conditions, using confined dogs and collecting saliva early after deposition. DNA concentration in saliva extracts was generally high (mean 14 ng μl(-1. We correctly identified individuals in 78% of samples conservatively using ten microsatellite loci, and 90% of samples using only eight loci. Consensus genotypes closely matched reference genotypes obtained from hair DNA (99% of identification successes and 91% of failures. Mean genotyping effort needed for identification using ten loci was 2.2 replicates. Genotyping errors occurred at a very low frequency (allelic dropout: 2.3%; false alleles: 1.5%. Individual identification success increased with duration of substrate handling inside dog's mouth and the volume of saliva collected. Low identification success was associated with baits rich in DNA-oxidant polyphenols and DNA concentrations <1 ng μl(-1. The procedure performed at least as well as other noninvasive methods, and could advantageously allow detection of socially low-ranked individuals underrepresented in sources of DNA that are involved in marking behaviour (faeces or urine. Once adapted and refined, there is promise for this technique to allow potentially high rates of individual identification in ecological field studies requiring noninvasive sampling of wild vertebrates.

  11. Importance of sampling frequency when collecting diatoms

    KAUST Repository

    Wu, Naicheng; Faber, Claas; Sun, Xiuming; Qu, Yueming; Wang, Chao; Ivetic, Snjezana; Riis, Tenna; Ulrich, Uta; Fohrer, Nicola

    2016-01-01

    There has been increasing interest in diatom-based bio-assessment but we still lack a comprehensive understanding of how to capture diatoms’ temporal dynamics with an appropriate sampling frequency (ASF). To cover this research gap, we collected

  12. Molecular dynamics based enhanced sampling of collective variables with very large time steps

    Science.gov (United States)

    Chen, Pei-Yang; Tuckerman, Mark E.

    2018-01-01

    Enhanced sampling techniques that target a set of collective variables and that use molecular dynamics as the driving engine have seen widespread application in the computational molecular sciences as a means to explore the free-energy landscapes of complex systems. The use of molecular dynamics as the fundamental driver of the sampling requires the introduction of a time step whose magnitude is limited by the fastest motions in a system. While standard multiple time-stepping methods allow larger time steps to be employed for the slower and computationally more expensive forces, the maximum achievable increase in time step is limited by resonance phenomena, which inextricably couple fast and slow motions. Recently, we introduced deterministic and stochastic resonance-free multiple time step algorithms for molecular dynamics that solve this resonance problem and allow ten- to twenty-fold gains in the large time step compared to standard multiple time step algorithms [P. Minary et al., Phys. Rev. Lett. 93, 150201 (2004); B. Leimkuhler et al., Mol. Phys. 111, 3579-3594 (2013)]. These methods are based on the imposition of isokinetic constraints that couple the physical system to Nosé-Hoover chains or Nosé-Hoover Langevin schemes. In this paper, we show how to adapt these methods for collective variable-based enhanced sampling techniques, specifically adiabatic free-energy dynamics/temperature-accelerated molecular dynamics, unified free-energy dynamics, and by extension, metadynamics, thus allowing simulations employing these methods to employ similarly very large time steps. The combination of resonance-free multiple time step integrators with free-energy-based enhanced sampling significantly improves the efficiency of conformational exploration.

  13. Collect method of uranium hexafluoride

    International Nuclear Information System (INIS)

    Moura, S.C.; Bustillos, O.W.V.

    1991-01-01

    A collect method of uranium hexafluoride was designed, constructed and assembled in Analytical Laboratory from Instituto de Energia Atomica, Sao Paulo, Brazil. This method of collect is main for quality control of uranium hexafluoride. (author)

  14. The use of Geographic Information System (GIS) and non-GIS methods to assess the external validity of samples postcollection.

    Science.gov (United States)

    Richardson, Esther; Good, Margaret; McGrath, Guy; More, Simon J

    2009-09-01

    External validity is fundamental to veterinary diagnostic investigation, reflecting the accuracy with which sample results can be extrapolated to a broader population of interest. Probability sampling methods are routinely used during the collection of samples from populations, specifically to maximize external validity. Nonprobability sampling (e.g., of blood samples collected as part of routine surveillance programs or laboratory submissions) may provide useful data for further posthoc epidemiological analysis, adding value to the collection and submission of samples. As the sample has already been submitted, the analyst or investigator does not have any control over the sampling methodology, and hence external validity as routine probability sampling methods may not have been employed. The current study describes several Geographic Information System (GIS) and non-GIS methods, applied posthoc, to assess the external validity of samples collected using both probability and nonprobability sampling methods. These methods could equally be employed for inspecting other datasets. Mapping was conducted using ArcView 9.1. Based on this posthoc assessment, results from the random field sample could provide an externally valid, albeit relatively imprecise, estimate of national disease prevalence, of disease prevalence in 3 of the 4 provinces (all but Ulster, in the north and northwest, where sample size was small), and in beef and dairy herds. This study provides practical methods for examining the external validity of samples postcollection.

  15. DOE methods for evaluating environmental and waste management samples

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K. [eds.

    1994-10-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Analytical Services Division of DOE. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types, {open_quotes}Draft{close_quotes} or {open_quotes}Verified{close_quotes}. {open_quotes}Draft{close_quotes} methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. {open_quotes}Verified{close_quotes} methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations. These methods have delineated measures of precision and accuracy.

  16. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1994-10-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Analytical Services Division of DOE. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types, open-quotes Draftclose quotes or open-quotes Verifiedclose quotes. open-quotes Draftclose quotes methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. open-quotes Verifiedclose quotes methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations. These methods have delineated measures of precision and accuracy

  17. Field evaluation of personal sampling methods for multiple bioaerosols.

    Science.gov (United States)

    Wang, Chi-Hsun; Chen, Bean T; Han, Bor-Cheng; Liu, Andrew Chi-Yeu; Hung, Po-Chen; Chen, Chih-Yong; Chao, Hsing Jasmine

    2015-01-01

    Ambient bioaerosols are ubiquitous in the daily environment and can affect health in various ways. However, few studies have been conducted to comprehensively evaluate personal bioaerosol exposure in occupational and indoor environments because of the complex composition of bioaerosols and the lack of standardized sampling/analysis methods. We conducted a study to determine the most efficient collection/analysis method for the personal exposure assessment of multiple bioaerosols. The sampling efficiencies of three filters and four samplers were compared. According to our results, polycarbonate (PC) filters had the highest relative efficiency, particularly for bacteria. Side-by-side sampling was conducted to evaluate the three filter samplers (with PC filters) and the NIOSH Personal Bioaerosol Cyclone Sampler. According to the results, the Button Aerosol Sampler and the IOM Inhalable Dust Sampler had the highest relative efficiencies for fungi and bacteria, followed by the NIOSH sampler. Personal sampling was performed in a pig farm to assess occupational bioaerosol exposure and to evaluate the sampling/analysis methods. The Button and IOM samplers yielded a similar performance for personal bioaerosol sampling at the pig farm. However, the Button sampler is more likely to be clogged at high airborne dust concentrations because of its higher flow rate (4 L/min). Therefore, the IOM sampler is a more appropriate choice for performing personal sampling in environments with high dust levels. In summary, the Button and IOM samplers with PC filters are efficient sampling/analysis methods for the personal exposure assessment of multiple bioaerosols.

  18. Variability and reliability of POP concentrations in multiple breast milk samples collected from the same mothers.

    Science.gov (United States)

    Kakimoto, Risa; Ichiba, Masayoshi; Matsumoto, Akiko; Nakai, Kunihiko; Tatsuta, Nozomi; Iwai-Shimada, Miyuki; Ishiyama, Momoko; Ryuda, Noriko; Someya, Takashi; Tokumoto, Ieyasu; Ueno, Daisuke

    2018-01-13

    Risk assessment of infant using a realistic persistent organic pollutant (POP) exposure through breast milk is essential to devise future regulation of POPs. However, recent investigations have demonstrated that POP levels in breast milk collected from the same mother showed a wide range of variation daily and monthly. To estimate the appropriate sample size of breast milk from the same mother to obtain reliable POP concentrations, breast milk samples were collected from five mothers living in Japan from 2006 to 2012. Milk samples from each mother were collected 3 to 6 times a day through 3 to 7 days consecutively. Food samples as the duplicated method were collected from two mothers during the period of breast milk sample collection. Those were employed for POP (PCBs, DDTs, chlordanes, and HCB) analysis. PCB concentrations detected in breast milk samples showed a wide range of variation which was maximum 63 and 60% of relative standard deviation (RSD) in lipid and wet weight basis, respectively. The time course trend of those variations among the mothers did not show any typical pattern. A larger amount of PCB intake through food seemed to affect 10 h after those concentrations in breast milk in lipid weight basis. Intraclass correlation coefficient (ICC) analyses indicated that the appropriate sample size for good reproducibility of POP concentrations in breast milk required at least two samples for lipid and wet weight basis.

  19. Sample collection and sample analysis plan in support of the 105-C/190-C concrete and soil sampling activities

    International Nuclear Information System (INIS)

    Marske, S.G.

    1996-07-01

    This sampling and analysis plan describes the sample collection and sample analysis in support of the 105-C water tunnels and 190-C main pumphouse concrete and soil sampling activities. These analytical data will be used to identify the radiological contamination and presence of hazardous materials to support the decontamination and disposal activities

  20. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    Science.gov (United States)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  1. Evaluation of a new simple collection device for sampling of microparticles in exhaled breath.

    Science.gov (United States)

    Seferaj, Sabina; Ullah, Shahid; Tinglev, Åsa; Carlsson, Sten; Winberg, Jesper; Stambeck, Peter; Beck, Olof

    2018-03-12

    The microparticle fraction of exhaled breath is of interest for developing clinical biomarkers. Exhaled particles may contain non-volatile components from all parts of the airway system, formed during normal breathing. This study aimed to evaluate a new, simple sampling device, based on impaction, for collecting microparticles from exhaled breath. Performance of the new device was compared with that of the existing SensAbues membrane filter device. The analytical work used liquid chromatography-tandem mass spectrometry methods. The new device collected three subsamples and these were separately analysed from eight individuals. No difference was observed between the centre position (0.91 ng/sample) and the side positions (1.01 ng/sample) using major phosphatidylcholine (PC) 16:0/16:0 as the analyte. Exhaled breath was collected from eight patients on methadone maintenance treatment. The intra-individual variability in measured methadone concentration between the three collectors was 8.7%. In another experiment using patients on methadone maintenance treatment, the sampling efficiency was compared with an established filter device. Compared to the existing device, the efficiency of the new device was 121% greater for methadone and 1450% greater for DPPC. The data from lipid analysis also indicated that a larger fraction of the collected material was from the distal parts. Finally, a study using an optical particle counter indicated that the device preferentially collects the larger particle fraction. In conclusion, this study demonstrates the usefulness of the new device for collecting non-volatile components from exhaled breath. The performance of the device was superior to the filter device in several aspects.

  2. Quality standards for sample collection in coagulation testing.

    Science.gov (United States)

    Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Lima-Oliveira, Gabriel; Guidi, Gian Cesare; Favaloro, Emmanuel J

    2012-09-01

    Preanalytical activities, especially those directly connected with blood sample collection and handling, are the most vulnerable steps throughout the testing process. The receipt of unsuitable samples is commonplace in laboratory practice and represents a serious problem, given the reliability of test results can be adversely compromised following analysis of these specimens. The basic criteria for an appropriate and safe venipuncture are nearly identical to those used for collecting blood for clinical chemistry and immunochemistry testing, and entail proper patient identification, use of the correct technique, as well as appropriate devices and needles. There are, however, some peculiar aspects, which are deemed to be particularly critical when collecting quality specimens for clot-based tests, and these require clearer recognition. These include prevention of prolonged venous stasis, collection of nonhemolyzed specimens, order of draw, and appropriate filling and mixing of the primary collection tubes. All of these important preanalytical issues are discussed in this article, and evidence-based suggestions as well as recommendations on how to obtain a high-quality sample for coagulation testing are also illustrated. We have also performed an investigation aimed to identify variation of test results due to underfilling of primary blood tubes, and have identified a clinically significant bias in test results when tubes are drawn at less than 89% of total fill for activated partial thromboplastin time, less than 78% for fibrinogen, and less than 67% for coagulation factor VIII, whereas prothrombin time and activated protein C resistance remain relatively reliable even in tubes drawn at 67% of the nominal volume. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  3. 22 CFR 34.10 - Collection methods.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Collection methods. 34.10 Section 34.10 Foreign... Collection methods. Upon completion of notice and provision of all due process rights as listed in 34.8(b) of... collect the debt by one or more of the following methods: (a) Administrative offset. (1) Payments...

  4. Impact of collection container material and holding times on sample integrity for mercury and methylmercury in water

    Energy Technology Data Exchange (ETDEWEB)

    Riscassi, Ami L [ORNL; Miller, Carrie L [ORNL; Brooks, Scott C [ORNL

    2014-01-01

    Mercury (Hg) and methylmercury (MeHg) concentrations in streamwater can vary on short timescales (hourly or less) during storm flow and on a diel cycle; the frequency and timing of sampling required to accurately characterize these dynamics may be difficult to accomplish manually. Automated sampling can assist in sample collection; however use has been limited for Hg and MeHg analysis due to stability concerns of trace concentrations during extended storage times. We examined the viability of using automated samplers with disposable low-density polyethylene (LDPE) sample bags to collect industrially contaminated streamwater for unfiltered and filtered Hg and MeHg analysis. Specifically we investigated the effect of holding times ranging from hours to days on streamwater collected during baseflow and storm flow. Unfiltered and filtered Hg and MeHg concentrations decreased with increases in time prior to sample processing; holding times of 24 hours or less resulted in concentration changes (mean 11 7% different) similar to variability in duplicates collected manually during analogous field conditions (mean 7 10% different). Comparisons of samples collected with manual and automated techniques throughout a year for a wide range of stream conditions were also found to be similar to differences observed between duplicate grab samples. These results demonstrate automated sampling into LDPE bags with holding times of 24 hours or less can be effectively used to collect streamwater for Hg and MeHg analysis, and encourage the testing of these materials and methods for implementation in other aqueous systems where high-frequency sampling is warranted.

  5. Field evaluation of personal sampling methods for multiple bioaerosols.

    Directory of Open Access Journals (Sweden)

    Chi-Hsun Wang

    Full Text Available Ambient bioaerosols are ubiquitous in the daily environment and can affect health in various ways. However, few studies have been conducted to comprehensively evaluate personal bioaerosol exposure in occupational and indoor environments because of the complex composition of bioaerosols and the lack of standardized sampling/analysis methods. We conducted a study to determine the most efficient collection/analysis method for the personal exposure assessment of multiple bioaerosols. The sampling efficiencies of three filters and four samplers were compared. According to our results, polycarbonate (PC filters had the highest relative efficiency, particularly for bacteria. Side-by-side sampling was conducted to evaluate the three filter samplers (with PC filters and the NIOSH Personal Bioaerosol Cyclone Sampler. According to the results, the Button Aerosol Sampler and the IOM Inhalable Dust Sampler had the highest relative efficiencies for fungi and bacteria, followed by the NIOSH sampler. Personal sampling was performed in a pig farm to assess occupational bioaerosol exposure and to evaluate the sampling/analysis methods. The Button and IOM samplers yielded a similar performance for personal bioaerosol sampling at the pig farm. However, the Button sampler is more likely to be clogged at high airborne dust concentrations because of its higher flow rate (4 L/min. Therefore, the IOM sampler is a more appropriate choice for performing personal sampling in environments with high dust levels. In summary, the Button and IOM samplers with PC filters are efficient sampling/analysis methods for the personal exposure assessment of multiple bioaerosols.

  6. Comparisons of methods for generating conditional Poisson samples and Sampford samples

    OpenAIRE

    Grafström, Anton

    2005-01-01

    Methods for conditional Poisson sampling (CP-sampling) and Sampford sampling are compared and the focus is on the efficiency of the methods. The efficiency is investigated by simulation in different sampling situations. It was of interest to compare methods since new methods for both CP-sampling and Sampford sampling were introduced by Bondesson, Traat & Lundqvist in 2004. The new methods are acceptance rejection methods that use the efficient Pareto sampling method. They are found to be ...

  7. Comparison of vapor sampling system (VSS) and in situ vapor sampling (ISVS) methods on Tanks C-107, BY-108, and S-102. Revision 1

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Edwards, J.A.; Evans, J.C.

    1996-08-01

    This report discusses comparison tests for two methods of collecting vapor samples from the Hanford Site high-level radioactive waste tank headspaces. The two sampling methods compared are the truck-mounted vapor sampling system (VSS) and the cart-mounted in-situ vapor sampling (ISVS). Three tanks were sampled by both the VSS and ISVS methods from the same access risers within the same 8-hour period. These tanks have diverse headspace compositions and they represent the highest known level of several key vapor analytes

  8. Measurement of technetium-99 in soil samples collected in Marshall Islands

    Energy Technology Data Exchange (ETDEWEB)

    Tagami, K.; Uchida, S. [National Inst. of Radiological Sciences, Environmental and Toxicological Sciences Research Group, Chiba (Japan)

    2000-07-01

    Extraction techniques for recovery of technetium-99 ({sup 99}Tc) for ICP-MS measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for {sup 99}Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the {sup 99}Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The {sup 99}Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq/g-dw. The limit of detection for {sup 99}Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq/g-dw under standard operating conditions. (author)

  9. Measurement of technetium-99 in soil samples collected in Marshall Islands

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.

    2000-01-01

    Extraction techniques for recovery of technetium-99 ( 99 Tc) for ICP-MS measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99 Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99 Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99 Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq/g-dw. The limit of detection for 99 Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq/g-dw under standard operating conditions. (author)

  10. Fluid sample collection and distribution system. [qualitative analysis of aqueous samples from several points

    Science.gov (United States)

    Brooks, R. L. (Inventor)

    1979-01-01

    A multipoint fluid sample collection and distribution system is provided wherein the sample inputs are made through one or more of a number of sampling valves to a progressive cavity pump which is not susceptible to damage by large unfiltered particles. The pump output is through a filter unit that can provide a filtered multipoint sample. An unfiltered multipoint sample is also provided. An effluent sample can be taken and applied to a second progressive cavity pump for pumping to a filter unit that can provide one or more filtered effluent samples. The second pump can also provide an unfiltered effluent sample. Means are provided to periodically back flush each filter unit without shutting off the whole system.

  11. Characterizing lentic freshwater fish assemblages using multiple sampling methods

    Science.gov (United States)

    Fischer, Jesse R.; Quist, Michael C.

    2014-01-01

    Characterizing fish assemblages in lentic ecosystems is difficult, and multiple sampling methods are almost always necessary to gain reliable estimates of indices such as species richness. However, most research focused on lentic fish sampling methodology has targeted recreationally important species, and little to no information is available regarding the influence of multiple methods and timing (i.e., temporal variation) on characterizing entire fish assemblages. Therefore, six lakes and impoundments (48–1,557 ha surface area) were sampled seasonally with seven gear types to evaluate the combined influence of sampling methods and timing on the number of species and individuals sampled. Probabilities of detection for species indicated strong selectivities and seasonal trends that provide guidance on optimal seasons to use gears when targeting multiple species. The evaluation of species richness and number of individuals sampled using multiple gear combinations demonstrated that appreciable benefits over relatively few gears (e.g., to four) used in optimal seasons were not present. Specifically, over 90 % of the species encountered with all gear types and season combinations (N = 19) from six lakes and reservoirs were sampled with nighttime boat electrofishing in the fall and benthic trawling, modified-fyke, and mini-fyke netting during the summer. Our results indicated that the characterization of lentic fish assemblages was highly influenced by the selection of sampling gears and seasons, but did not appear to be influenced by waterbody type (i.e., natural lake, impoundment). The standardization of data collected with multiple methods and seasons to account for bias is imperative to monitoring of lentic ecosystems and will provide researchers with increased reliability in their interpretations and decisions made using information on lentic fish assemblages.

  12. Quantification of total aluminium concentrations in food samples at trace levels by INAA and PIGE methods

    International Nuclear Information System (INIS)

    Nanda, Braja B.; Acharya, R.

    2017-01-01

    Total aluminium contents in various food samples were determined by Instrumental Neutron Activation Analysis (INAA) and Particle Induced Gamma-ray Emission (PIGE) methods. A total of 16 rice samples, collected from the field, were analyzed by INAA using reactor neutrons from Dhruva reactor. Whereas a total 17 spices collected from market, were analyzed by both INAA and PIGE methods in conjunction with high resolution gamma-ray spectrometry. Aluminium concentration values were found to be in the range of 19-845 mg kg -1 for spices and 15-104 mg kg -1 for rice samples. The methods were validated by analyzing standard reference materials (SRMs) form NIST. (author)

  13. Collection and control of tritium bioassay samples at Pantex

    International Nuclear Information System (INIS)

    Fairrow, N.L.; Ivie, W.E.

    1992-01-01

    Pantex is the final assembly/disassembly point for US nuclear weapons. The Pantex internal dosimetry section monitors radiation workers once a month for tritium exposure. In order to manage collection and control of the bioassay specimens efficiently, a bar code system for collection of samples was developed and implemented to speed up the process and decrease the number of errors probable when transferring data. In the past, all the bioassay data from samples were entered manually into a computer database. Transferring the bioassay data from the liquid scintillation counter to each individual's dosimetry record required as much as two weeks of concentrated effort

  14. Disposable Collection Kit for Rapid and Reliable Collection of Saliva

    OpenAIRE

    Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek

    2015-01-01

    Objectives To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. Methods The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 ?l) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method...

  15. The UK Biobank sample handling and storage protocol for the collection, processing and archiving of human blood and urine.

    Science.gov (United States)

    Elliott, Paul; Peakman, Tim C

    2008-04-01

    UK Biobank is a large prospective study in the UK to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. Extensive data and biological samples are being collected from 500,000 participants aged between 40 and 69 years. The biological samples that are collected and how they are processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. The aim of the UK Biobank sample handling and storage protocol is to specify methods for the collection and storage of participant samples that give maximum scientific return within the available budget. Processing or storage methods that, as far as can be predicted, will preclude current or future assays have been avoided. The protocol was developed through a review of the literature on sample handling and processing, wide consultation within the academic community and peer review. Protocol development addressed which samples should be collected, how and when they should be processed and how the processed samples should be stored to ensure their long-term integrity. The recommended protocol was extensively tested in a series of validation studies. UK Biobank collects about 45 ml blood and 9 ml of urine with minimal local processing from each participant using the vacutainer system. A variety of preservatives, anti-coagulants and clot accelerators is used appropriate to the expected end use of the samples. Collection of other material (hair, nails, saliva and faeces) was also considered but rejected for the full cohort. Blood and urine samples from participants are transported overnight by commercial courier to a central laboratory where they are processed and aliquots of urine, plasma, serum, white cells and red cells stored in ultra-low temperature archives. Aliquots of whole blood are also stored for potential future production of immortalized cell lines. A standard panel of haematology assays is

  16. Metagenomic survey of bacterial diversity in the atmosphere of Mexico City using different sampling methods.

    Science.gov (United States)

    Serrano-Silva, N; Calderón-Ezquerro, M C

    2018-04-01

    The identification of airborne bacteria has traditionally been performed by retrieval in culture media, but the bacterial diversity in the air is underestimated using this method because many bacteria are not readily cultured. Advances in DNA sequencing technology have produced a broad knowledge of genomics and metagenomics, which can greatly improve our ability to identify and study the diversity of airborne bacteria. However, researchers are facing several challenges, particularly the efficient retrieval of low-density microorganisms from the air and the lack of standardized protocols for sample collection and processing. In this study, we tested three methods for sampling bioaerosols - a Durham-type spore trap (Durham), a seven-day recording volumetric spore trap (HST), and a high-throughput 'Jet' spore and particle sampler (Jet) - and recovered metagenomic DNA for 16S rDNA sequencing. Samples were simultaneously collected with the three devices during one week, and the sequencing libraries were analyzed. A simple and efficient method for collecting bioaerosols and extracting good quality DNA for high-throughput sequencing was standardized. The Durham sampler collected preferentially Cyanobacteria, the HST Actinobacteria, Proteobacteria and Firmicutes, and the Jet mainly Proteobacteria and Firmicutes. The HST sampler collected the largest amount of airborne bacterial diversity. More experiments are necessary to select the right sampler, depending on study objectives, which may require monitoring and collecting specific airborne bacteria. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods.

    Science.gov (United States)

    Coes, Alissa L; Paretti, Nicholas V; Foreman, William T; Iverson, Jana L; Alvarez, David A

    2014-03-01

    A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19-23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method. Published by Elsevier B.V.

  18. Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods

    Science.gov (United States)

    Coes, Alissa L.; Paretti, Nicholas V.; Foreman, William T.; Iverson, Jana L.; Alvarez, David A.

    2014-01-01

    A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19–23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method.

  19. Tritium concentrations in environmental water and food samples collected around the vicinity of the PNPP-1

    International Nuclear Information System (INIS)

    Garcia, T.Y.; Enriquez, S.O.; Duran, E.B.

    1986-01-01

    The natural radioactivity levels of tritium in environmental samples collected around the vicinity and more distant environment of the first Philippine Nuclear Power Plant (PNPP-1) in Bataan were assessed. The samples analyzed consisted of water samples such as seawater, freshwater, drinking water, groundwater and rainwater; and food samples such as cereals, vegetables, fruits; meat, milk fish and crustaceans. Tritium concentrations in water samples were determined by distillation and liquid scintillation counting techniques. The food samples were analyzed for tissue-free water tritium by the freezing-drying method followed by liquid scintillation counting techniques. (Auth.) 13 refs

  20. Bridging the gap between sample collection and laboratory analysis: using dried blood spots to identify human exposure to chemical agents

    Science.gov (United States)

    Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.

    2016-05-01

    Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.

  1. Challenges in collecting clinical samples for research from pregnant women of South Asian origin: evidence from a UK study.

    Science.gov (United States)

    Neelotpol, Sharmind; Hay, Alastair W M; Jolly, A Jim; Woolridge, Mike W

    2016-08-31

    To recruit South Asian pregnant women, living in the UK, into a clinicoepidemiological study for the collection of lifestyle survey data and antenatal blood and to retain the women for the later collection of cord blood and meconium samples from their babies for biochemical analysis. A longitudinal study recruiting pregnant women of South Asian and Caucasian origin living in the UK. Recruitment of the participants, collection of clinical samples and survey data took place at the 2 sites within a single UK Northern Hospital Trust. Pregnant women of South Asian origin (study group, n=98) and of Caucasian origin (comparison group, n=38) living in Leeds, UK. Among the participants approached, 81% agreed to take part in the study while a 'direct approach' method was followed. The retention rate of the participants was a remarkable 93.4%. The main challenges in recruiting the ethnic minority participants were their cultural and religious conservativeness, language barrier, lack of interest and feeling of extra 'stress' in taking part in research. The chief investigator developed an innovative participant retention method, associated with the women's cultural and religious practices. The method proved useful in retaining the participants for about 5 months and in enabling successful collection of clinical samples from the same mother-baby pairs. The collection of clinical samples and lifestyle data exceeded the calculated sample size required to give the study sufficient power. The numbers of samples obtained were: maternal blood (n=171), cord blood (n=38), meconium (n=176), lifestyle questionnaire data (n=136) and postnatal records (n=136). Recruitment and retention of participants, according to the calculated sample size, ensured sufficient power and success for a clinicoepidemiological study. Results suggest that development of trust and confidence between the participant and the researcher is the key to the success of a clinical and epidemiological study involving

  2. Comparing Microbiome Sampling Methods in a Wild Mammal: Fecal and Intestinal Samples Record Different Signals of Host Ecology, Evolution.

    Science.gov (United States)

    Ingala, Melissa R; Simmons, Nancy B; Wultsch, Claudia; Krampis, Konstantinos; Speer, Kelly A; Perkins, Susan L

    2018-01-01

    The gut microbiome is a community of host-associated symbiotic microbes that fulfills multiple key roles in host metabolism, immune function, and tissue development. Given the ability of the microbiome to impact host fitness, there is increasing interest in studying the microbiome of wild animals to better understand these communities in the context of host ecology and evolution. Human microbiome research protocols are well established, but wildlife microbiome research is still a developing field. Currently, there is no standardized set of best practices guiding the collection of microbiome samples from wildlife. Gut microflora are typically sampled either by fecal collection, rectal swabbing, or by destructively sampling the intestinal contents of the host animal. Studies rarely include more than one sampling technique and no comparison of these methods currently exists for a wild mammal. Although some studies have hypothesized that the fecal microbiome is a nested subset of the intestinal microbiome, this hypothesis has not been formally tested. To address these issues, we examined guano (feces) and distal intestinal mucosa from 19 species of free-ranging bats from Lamanai, Belize, using 16S rRNA amplicon sequencing to compare microbial communities across sample types. We found that the diversity and composition of intestine and guano samples differed substantially. In addition, we conclude that signatures of host evolution are retained by studying gut microbiomes based on mucosal tissue samples, but not fecal samples. Conversely, fecal samples retained more signal of host diet than intestinal samples. These results suggest that fecal and intestinal sampling methods are not interchangeable, and that these two microbiotas record different information about the host from which they are isolated.

  3. Comparing Microbiome Sampling Methods in a Wild Mammal: Fecal and Intestinal Samples Record Different Signals of Host Ecology, Evolution

    Directory of Open Access Journals (Sweden)

    Melissa R. Ingala

    2018-05-01

    Full Text Available The gut microbiome is a community of host-associated symbiotic microbes that fulfills multiple key roles in host metabolism, immune function, and tissue development. Given the ability of the microbiome to impact host fitness, there is increasing interest in studying the microbiome of wild animals to better understand these communities in the context of host ecology and evolution. Human microbiome research protocols are well established, but wildlife microbiome research is still a developing field. Currently, there is no standardized set of best practices guiding the collection of microbiome samples from wildlife. Gut microflora are typically sampled either by fecal collection, rectal swabbing, or by destructively sampling the intestinal contents of the host animal. Studies rarely include more than one sampling technique and no comparison of these methods currently exists for a wild mammal. Although some studies have hypothesized that the fecal microbiome is a nested subset of the intestinal microbiome, this hypothesis has not been formally tested. To address these issues, we examined guano (feces and distal intestinal mucosa from 19 species of free-ranging bats from Lamanai, Belize, using 16S rRNA amplicon sequencing to compare microbial communities across sample types. We found that the diversity and composition of intestine and guano samples differed substantially. In addition, we conclude that signatures of host evolution are retained by studying gut microbiomes based on mucosal tissue samples, but not fecal samples. Conversely, fecal samples retained more signal of host diet than intestinal samples. These results suggest that fecal and intestinal sampling methods are not interchangeable, and that these two microbiotas record different information about the host from which they are isolated.

  4. Series: Practical guidance to qualitative research. Part 3: Sampling, data collection and analysis.

    Science.gov (United States)

    Moser, Albine; Korstjens, Irene

    2018-12-01

    In the course of our supervisory work over the years, we have noticed that qualitative research tends to evoke a lot of questions and worries, so-called frequently asked questions (FAQs). This series of four articles intends to provide novice researchers with practical guidance for conducting high-quality qualitative research in primary care. By 'novice' we mean Master's students and junior researchers, as well as experienced quantitative researchers who are engaging in qualitative research for the first time. This series addresses their questions and provides researchers, readers, reviewers and editors with references to criteria and tools for judging the quality of qualitative research papers. The second article focused on context, research questions and designs, and referred to publications for further reading. This third article addresses FAQs about sampling, data collection and analysis. The data collection plan needs to be broadly defined and open at first, and become flexible during data collection. Sampling strategies should be chosen in such a way that they yield rich information and are consistent with the methodological approach used. Data saturation determines sample size and will be different for each study. The most commonly used data collection methods are participant observation, face-to-face in-depth interviews and focus group discussions. Analyses in ethnographic, phenomenological, grounded theory, and content analysis studies yield different narrative findings: a detailed description of a culture, the essence of the lived experience, a theory, and a descriptive summary, respectively. The fourth and final article will focus on trustworthiness and publishing qualitative research.

  5. Series: Practical guidance to qualitative research. Part 3: Sampling, data collection and analysis

    Science.gov (United States)

    Moser, Albine; Korstjens, Irene

    2018-01-01

    Abstract In the course of our supervisory work over the years, we have noticed that qualitative research tends to evoke a lot of questions and worries, so-called frequently asked questions (FAQs). This series of four articles intends to provide novice researchers with practical guidance for conducting high-quality qualitative research in primary care. By ‘novice’ we mean Master’s students and junior researchers, as well as experienced quantitative researchers who are engaging in qualitative research for the first time. This series addresses their questions and provides researchers, readers, reviewers and editors with references to criteria and tools for judging the quality of qualitative research papers. The second article focused on context, research questions and designs, and referred to publications for further reading. This third article addresses FAQs about sampling, data collection and analysis. The data collection plan needs to be broadly defined and open at first, and become flexible during data collection. Sampling strategies should be chosen in such a way that they yield rich information and are consistent with the methodological approach used. Data saturation determines sample size and will be different for each study. The most commonly used data collection methods are participant observation, face-to-face in-depth interviews and focus group discussions. Analyses in ethnographic, phenomenological, grounded theory, and content analysis studies yield different narrative findings: a detailed description of a culture, the essence of the lived experience, a theory, and a descriptive summary, respectively. The fourth and final article will focus on trustworthiness and publishing qualitative research. PMID:29199486

  6. Comparison of glomerular filtration rate measured by plasma sample technique, Cockroft Gault method and Gates’ method in voluntary kidney donors and renal transplant recipients

    International Nuclear Information System (INIS)

    Hephzibah, Julie; Shanthly, Nylla; Oommen, Regi

    2013-01-01

    There are numerous methods for calculation of glomerular filtration rate (GFR), which is a crucial measurement to identify patients with renal disease. The aim of this study is to compare four different methods of GFR calculation. Clinical setup, prospective study. Data was collected from routine renal scans done for voluntary kidney donors (VKD) or renal transplant recipients 6 months after transplantation. Following technetium-99m diethylene triamine penta acetic acid injection, venous blood samples were collected from contralateral arm at 120, 180, and 240 min through an indwelling venous cannula and direct collection by syringe. A total volume of 1 ml of plasma from each sample and standards were counted in an automatic gamma counter for 1 min. Blood samples taken at 120 min and 240 min were used for double plasma sample method (DPSM) and a sample taken at 180 min for single plasma sample method (SPSM). Russell's formulae for SPSM and DPSM were used for GFR estimation. Gates’ method GFR was calculated by vendor provided software. Correlation analysis was performed using Pearson's correlation test. SPSM correlated well with DPSM. GFR value in healthy potential kidney donors has a significant role in the selection of donors. The mean GFR ± (standard deviation) in VKD using SPSM, DPSM, camera depth method and Cockroft Gault method was 134.6 (25.9), 137.5 (42.4), 98.6 (15.9), 83.5 (21.1) respectively. Gates’ GFR calculation did not correlate well with plasma sampling method. Calculation of GFR plays a vital role in the management of renal patients, hence it was noted that Gates GFR may not be a reliable method of calculation. SPSM was more reliable. DPSM is reliable but cumbersome. It is difficult to accurately calculate GFR without a gold standard

  7. Distance sampling methods and applications

    CERN Document Server

    Buckland, S T; Marques, T A; Oedekoven, C S

    2015-01-01

    In this book, the authors cover the basic methods and advances within distance sampling that are most valuable to practitioners and in ecology more broadly. This is the fourth book dedicated to distance sampling. In the decade since the last book published, there have been a number of new developments. The intervening years have also shown which advances are of most use. This self-contained book covers topics from the previous publications, while also including recent developments in method, software and application. Distance sampling refers to a suite of methods, including line and point transect sampling, in which animal density or abundance is estimated from a sample of distances to detected individuals. The book illustrates these methods through case studies; data sets and computer code are supplied to readers through the book’s accompanying website.  Some of the case studies use the software Distance, while others use R code. The book is in three parts.  The first part addresses basic methods, the ...

  8. OSIRIS-REx Touch-and-Go (TAG) Mission Design for Asteroid Sample Collection

    Science.gov (United States)

    May, Alexander; Sutter, Brian; Linn, Timothy; Bierhaus, Beau; Berry, Kevin; Mink, Ron

    2014-01-01

    The Origins Spectral Interpretation Resource Identification Security Regolith Explorer (OSIRIS-REx) mission is a NASA New Frontiers mission launching in September 2016 to rendezvous with the near-Earth asteroid Bennu in October 2018. After several months of proximity operations to characterize the asteroid, OSIRIS-REx flies a Touch-And-Go (TAG) trajectory to the asteroid's surface to collect at least 60 g of pristine regolith sample for Earth return. This paper provides mission and flight system overviews, with more details on the TAG mission design and key events that occur to safely and successfully collect the sample. An overview of the navigation performed relative to a chosen sample site, along with the maneuvers to reach the desired site is described. Safety monitoring during descent is performed with onboard sensors providing an option to abort, troubleshoot, and try again if necessary. Sample collection occurs using a collection device at the end of an articulating robotic arm during a brief five second contact period, while a constant force spring mechanism in the arm assists to rebound the spacecraft away from the surface. Finally, the sample is measured quantitatively utilizing the law of conservation of angular momentum, along with qualitative data from imagery of the sampling device. Upon sample mass verification, the arm places the sample into the Stardust-heritage Sample Return Capsule (SRC) for return to Earth in September 2023.

  9. Water-quality assessment of south-central Texas : comparison of water quality in surface-water samples collected manually and by automated samplers

    Science.gov (United States)

    Ging, Patricia B.

    1999-01-01

    Surface-water sampling protocols of the U.S. Geological Survey National Water-Quality Assessment (NAWQA) Program specify samples for most properties and constituents to be collected manually in equal-width increments across a stream channel and composited for analysis. Single-point sampling with an automated sampler (autosampler) during storms was proposed in the upper part of the South-Central Texas NAWQA study unit, raising the question of whether property and constituent concentrations from automatically collected samples differ significantly from those in samples collected manually. Statistical (Wilcoxon signed-rank test) analyses of 3 to 16 paired concentrations for each of 26 properties and constituents from water samples collected using both methods at eight sites in the upper part of the study unit indicated that there were no significant differences in concentrations for dissolved constituents, other than calcium and organic carbon.

  10. Rapid, sensitive and reproducible method for point-of-collection screening of liquid milk for adulterants using a portable Raman spectrometer with novel optimized sample well

    Science.gov (United States)

    Nieuwoudt, Michel K.; Holroyd, Steve E.; McGoverin, Cushla M.; Simpson, M. Cather; Williams, David E.

    2017-02-01

    Point-of-care diagnostics are of interest in the medical, security and food industry, the latter particularly for screening food adulterated for economic gain. Milk adulteration continues to be a major problem worldwide and different methods to detect fraudulent additives have been investigated for over a century. Laboratory based methods are limited in their application to point-of-collection diagnosis and also require expensive instrumentation, chemicals and skilled technicians. This has encouraged exploration of spectroscopic methods as more rapid and inexpensive alternatives. Raman spectroscopy has excellent potential for screening of milk because of the rich complexity inherent in its signals. The rapid advances in photonic technologies and fabrication methods are enabling increasingly sensitive portable mini-Raman systems to be placed on the market that are both affordable and feasible for both point-of-care and point-of-collection applications. We have developed a powerful spectroscopic method for rapidly screening liquid milk for sucrose and four nitrogen-rich adulterants (dicyandiamide (DCD), ammonium sulphate, melamine, urea), using a combined system: a small, portable Raman spectrometer with focusing fibre optic probe and optimized reflective focusing wells, simply fabricated in aluminium. The reliable sample presentation of this system enabled high reproducibility of 8% RSD (residual standard deviation) within four minutes. Limit of detection intervals for PLS calibrations ranged between 140 - 520 ppm for the four N-rich compounds and between 0.7 - 3.6 % for sucrose. The portability of the system and reliability and reproducibility of this technique opens opportunities for general, reagentless adulteration screening of biological fluids as well as milk, at point-of-collection.

  11. Evaluation of sampling methods for toxicological testing of indoor air particulate matter.

    Science.gov (United States)

    Tirkkonen, Jenni; Täubel, Martin; Hirvonen, Maija-Riitta; Leppänen, Hanna; Lindsley, William G; Chen, Bean T; Hyvärinen, Anne; Huttunen, Kati

    2016-09-01

    There is a need for toxicity tests capable of recognizing indoor environments with compromised air quality, especially in the context of moisture damage. One of the key issues is sampling, which should both provide meaningful material for analyses and fulfill requirements imposed by practitioners using toxicity tests for health risk assessment. We aimed to evaluate different existing methods of sampling indoor particulate matter (PM) to develop a suitable sampling strategy for a toxicological assay. During three sampling campaigns in moisture-damaged and non-damaged school buildings, we evaluated one passive and three active sampling methods: the Settled Dust Box (SDB), the Button Aerosol Sampler, the Harvard Impactor and the National Institute for Occupational Safety and Health (NIOSH) Bioaerosol Cyclone Sampler. Mouse RAW264.7 macrophages were exposed to particle suspensions and cell metabolic activity (CMA), production of nitric oxide (NO) and tumor necrosis factor (TNFα) were determined after 24 h of exposure. The repeatability of the toxicological analyses was very good for all tested sampler types. Variability within the schools was found to be high especially between different classrooms in the moisture-damaged school. Passively collected settled dust and PM collected actively with the NIOSH Sampler (Stage 1) caused a clear response in exposed cells. The results suggested the higher relative immunotoxicological activity of dust from the moisture-damaged school. The NIOSH Sampler is a promising candidate for the collection of size-fractionated PM to be used in toxicity testing. The applicability of such sampling strategy in grading moisture damage severity in buildings needs to be developed further in a larger cohort of buildings.

  12. Single- versus multiple-sample method to measure glomerular filtration rate.

    Science.gov (United States)

    Delanaye, Pierre; Flamant, Martin; Dubourg, Laurence; Vidal-Petiot, Emmanuelle; Lemoine, Sandrine; Cavalier, Etienne; Schaeffner, Elke; Ebert, Natalie; Pottel, Hans

    2018-01-08

    There are many different ways to measure glomerular filtration rate (GFR) using various exogenous filtration markers, each having their own strengths and limitations. However, not only the marker, but also the methodology may vary in many ways, including the use of urinary or plasma clearance, and, in the case of plasma clearance, the number of time points used to calculate the area under the concentration-time curve, ranging from only one (Jacobsson method) to eight (or more) blood samples. We collected the results obtained from 5106 plasma clearances (iohexol or 51Cr-ethylenediaminetetraacetic acid (EDTA)) using three to four time points, allowing GFR calculation using the slope-intercept method and the Bröchner-Mortensen correction. For each time point, the Jacobsson formula was applied to obtain the single-sample GFR. We used Bland-Altman plots to determine the accuracy of the Jacobsson method at each time point. The single-sample method showed within 10% concordances with the multiple-sample method of 66.4%, 83.6%, 91.4% and 96.0% at the time points 120, 180, 240 and ≥300 min, respectively. Concordance was poorer at lower GFR levels, and this trend is in parallel with increasing age. Results were similar in males and females. Some discordance was found in the obese subjects. Single-sample GFR is highly concordant with a multiple-sample strategy, except in the low GFR range (<30 mL/min). © The Author 2018. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  13. [Sample preparation methods for chromatographic analysis of organic components in atmospheric particulate matter].

    Science.gov (United States)

    Hao, Liang; Wu, Dapeng; Guan, Yafeng

    2014-09-01

    The determination of organic composition in atmospheric particulate matter (PM) is of great importance in understanding how PM affects human health, environment, climate, and ecosystem. Organic components are also the scientific basis for emission source tracking, PM regulation and risk management. Therefore, the molecular characterization of the organic fraction of PM has become one of the priority research issues in the field of environmental analysis. Due to the extreme complexity of PM samples, chromatographic methods have been the chief selection. The common procedure for the analysis of organic components in PM includes several steps: sample collection on the fiber filters, sample preparation (transform the sample into a form suitable for chromatographic analysis), analysis by chromatographic methods. Among these steps, the sample preparation methods will largely determine the throughput and the data quality. Solvent extraction methods followed by sample pretreatment (e. g. pre-separation, derivatization, pre-concentration) have long been used for PM sample analysis, and thermal desorption methods have also mainly focused on the non-polar organic component analysis in PM. In this paper, the sample preparation methods prior to chromatographic analysis of organic components in PM are reviewed comprehensively, and the corresponding merits and limitations of each method are also briefly discussed.

  14. Improved sperm kinematics in semen samples collected after 2 h versus 4-7 days of ejaculation abstinence

    DEFF Research Database (Denmark)

    Alipour, H; Van Der Horst, G; Christiansen, O B

    2017-01-01

    STUDY QUESTION: Does a short abstinence period of only 2 h yield spermatozoa with better motility characteristics than samples collected after 4-7 days? SUMMARY ANSWER: Despite lower semen volume, sperm concentration, total sperm counts and total motile counts, higher percentages of motile...... a controlled repeated-measures design based on semen samples from 43 male partners, in couples attending for IVF treatment, who had a sperm concentration above 15 million/ml. Data were collected between June 2014 and December 2015 in the Fertility Unit of Aalborg University Hospital (Aalborg, Denmark......). PARTICIPANTS/MATERIALS, SETTING, METHODS: Participants provided a semen sample after 4-7 days of abstinence followed by another sample after only 2 h. For both ejaculates, sperm concentration, total sperm counts, motility groups and detailed kinematic parameters were assessed and compared by using the Sperm...

  15. Ground-water sample collection and analysis plan for the ground-water surveillance project

    International Nuclear Information System (INIS)

    Bryce, R.W.; Evans, J.C.; Olsen, K.B.

    1991-12-01

    The Pacific Northwest Laboratory performs ground-water sampling activities at the US Department of Energy's (DOE's) Hanford Site in support of DOE's environmental surveillance responsibilities. The purpose of this document is to translate DOE's General Environmental Protection Program (DOE Order 5400.1) into a comprehensive ground-water sample collection and analysis plan for the Hanford Site. This sample collection and analysis plan sets forth the environmental surveillance objectives applicable to ground water, identifies the strategy for selecting sample collection locations, and lists the analyses to be performed to meet those objectives

  16. Validation and Clinical Evaluation of a Novel Method To Measure Miltefosine in Leishmaniasis Patients Using Dried Blood Spot Sample Collection

    Science.gov (United States)

    Rosing, H.; Hillebrand, M. J. X.; Blesson, S.; Mengesha, B.; Diro, E.; Hailu, A.; Schellens, J. H. M.; Beijnen, J. H.

    2016-01-01

    To facilitate future pharmacokinetic studies of combination treatments against leishmaniasis in remote regions in which the disease is endemic, a simple cheap sampling method is required for miltefosine quantification. The aims of this study were to validate a liquid chromatography-tandem mass spectrometry method to quantify miltefosine in dried blood spot (DBS) samples and to validate its use with Ethiopian patients with visceral leishmaniasis (VL). Since hematocrit (Ht) levels are typically severely decreased in VL patients, returning to normal during treatment, the method was evaluated over a range of clinically relevant Ht values. Miltefosine was extracted from DBS samples using a simple method of pretreatment with methanol, resulting in >97% recovery. The method was validated over a calibration range of 10 to 2,000 ng/ml, and accuracy and precision were within ±11.2% and ≤7.0% (≤19.1% at the lower limit of quantification), respectively. The method was accurate and precise for blood spot volumes between 10 and 30 μl and for Ht levels of 20 to 35%, although a linear effect of Ht levels on miltefosine quantification was observed in the bioanalytical validation. DBS samples were stable for at least 162 days at 37°C. Clinical validation of the method using paired DBS and plasma samples from 16 VL patients showed a median observed DBS/plasma miltefosine concentration ratio of 0.99, with good correlation (Pearson's r = 0.946). Correcting for patient-specific Ht levels did not further improve the concordance between the sampling methods. This successfully validated method to quantify miltefosine in DBS samples was demonstrated to be a valid and practical alternative to venous blood sampling that can be applied in future miltefosine pharmacokinetic studies with leishmaniasis patients, without Ht correction. PMID:26787691

  17. Evaluation of methods to sample fecal indicator bacteria in foreshore sand and pore water at freshwater beaches.

    Science.gov (United States)

    Vogel, Laura J; Edge, Thomas A; O'Carroll, Denis M; Solo-Gabriele, Helena M; Kushnir, Caitlin S E; Robinson, Clare E

    2017-09-15

    Fecal indicator bacteria (FIB) are known to accumulate in foreshore beach sand and pore water (referred to as foreshore reservoir) where they act as a non-point source for contaminating adjacent surface waters. While guidelines exist for sampling surface waters at recreational beaches, there is no widely-accepted method to collect sand/sediment or pore water samples for FIB enumeration. The effect of different sampling strategies in quantifying the abundance of FIB in the foreshore reservoir is unclear. Sampling was conducted at six freshwater beaches with different sand types to evaluate sampling methods for characterizing the abundance of E. coli in the foreshore reservoir as well as the partitioning of E. coli between different components in the foreshore reservoir (pore water, saturated sand, unsaturated sand). Methods were evaluated for collection of pore water (drive point, shovel, and careful excavation), unsaturated sand (top 1 cm, top 5 cm), and saturated sand (sediment core, shovel, and careful excavation). Ankle-depth surface water samples were also collected for comparison. Pore water sampled with a shovel resulted in the highest observed E. coli concentrations (only statistically significant at fine sand beaches) and lowest variability compared to other sampling methods. Collection of the top 1 cm of unsaturated sand resulted in higher and more variable concentrations than the top 5 cm of sand. There were no statistical differences in E. coli concentrations when using different methods to sample the saturated sand. Overall, the unsaturated sand had the highest amount of E. coli when compared to saturated sand and pore water (considered on a bulk volumetric basis). The findings presented will help determine the appropriate sampling strategy for characterizing FIB abundance in the foreshore reservoir as a means of predicting its potential impact on nearshore surface water quality and public health risk. Copyright © 2017 Elsevier Ltd. All rights

  18. Acceptability and usability of self-collected sampling for HPV testing among African-American women living in the Mississippi Delta.

    Science.gov (United States)

    Scarinci, Isabel C; Litton, Allison G; Garcés-Palacio, Isabel C; Partridge, Edward E; Castle, Philip E

    2013-01-01

    Human papillomavirus (HPV) DNA testing has been shown to be an effective approach to cervical cancer screening, and self-collection sampling for HPV testing could be a potential alternative to Pap test, provided that women who tested positive by any method get timely follow-up and care. This feasibility study examined acceptability and usability of self-collected sampling for HPV testing among African-American (AA) women in the Mississippi Delta to inform the development of interventions to promote cervical cancer screening in this population. The study consisted of two phases. Phase I consisted of eight focus groups (n = 87) with AA women to explore knowledge, attitudes, and beliefs about cervical cancer and HPV infection as well as acceptability of self-collected sampling for HPV testing. In phase II, we examined the usability of this technology through one discussion group (n = 9). The Health Belief Model guided data collection and analysis. Although participants perceived themselves as susceptible to cervical cancer and acknowledged its severity, there was a lack of knowledge of the link between HPV and cervical cancer, and they expressed a number of misconceptions. The most frequent barriers to screening included embarrassment, discomfort, and fear of the results. Women in both phases were receptive to self-collected sampling for HPV testing. All participants in the usability phase expressed that self-collection was easy and they did not experience any difficulties. Self-collection for HPV testing is an acceptable and feasible method among AA women in the Mississippi Delta to complement current cytology cervical cancer screening programs. Copyright © 2013 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  19. Evaluation of biological samples for specimen banking and biomonitoring by nuclear methods

    International Nuclear Information System (INIS)

    Stone, S.F.; Zeisler, R.

    1984-01-01

    In a pilot program for environmental specimen banking, human livers and marine mussels (Mytilus edulis) were sampled, analyzed and banked. Nuclear methods played a major role in the evaluation of the samples by providing concentration data for up to 37 major, mineral, and trace elements. Instrumental neutron activation analysis was complemented by neutron-capture prompt gamma activation analysis, radiochemical separations and, for the mussels, by instrumental X-ray fluorescence analysis. A cryogenic homogenization procedure was applied for sample preparation and evaluated. Assessment of accuracy was made by analyzing Standard Reference Materials and by intercomparing the techniques. Results are reported for 66 individual human liver specimens, collected at three locations in the United States, and for batches of 65 mussels from a collection made at Narragansett Bay, RI. 19 references, 23 figures, 4 tables

  20. A Method for Determining the Content of Glycoproteins in Biological Samples

    Directory of Open Access Journals (Sweden)

    Yang Gao

    2016-11-01

    Full Text Available The glycoprotein purified from the mycelium extract of Tremella fuciformis was marked with iodine through the iodine substitution reaction. The content of iodine, which is indicative of the amount of the marked tremella glycoprotein (ITG, was detected with Inductively coupled plasma mass spectrometry (ICP-MS. The method was found to be stable, sensitive, and accurate at detecting the content of iodine-substituted glycoprotein, and was used in the quantitative analysis of biological samples, including blood and organs. Different biological samples were collected from rats after oral administration of ITG, and were tested for iodine content by ICP-MS to calculate the amount of ITG in the samples. The results suggested that ICP-MS is a sensitive, stable, and accurate method for detection of iodinated glycoproteins in blood and organs.

  1. Active Collection of Land Cover Sample Data from Geo-Tagged Web Texts

    Directory of Open Access Journals (Sweden)

    Dongyang Hou

    2015-05-01

    Full Text Available Sample data plays an important role in land cover (LC map validation. Traditionally, they are collected through field survey or image interpretation, either of which is costly, labor-intensive and time-consuming. In recent years, massive geo-tagged texts are emerging on the web and they contain valuable information for LC map validation. However, this kind of special textual data has seldom been analyzed and used for supporting LC map validation. This paper examines the potential of geo-tagged web texts as a new cost-free sample data source to assist LC map validation and proposes an active data collection approach. The proposed approach uses a customized deep web crawler to search for geo-tagged web texts based on land cover-related keywords and string-based rules matching. A data transformation based on buffer analysis is then performed to convert the collected web texts into LC sample data. Using three provinces and three municipalities directly under the Central Government in China as study areas, geo-tagged web texts were collected to validate artificial surface class of China’s 30-meter global land cover datasets (GlobeLand30-2010. A total of 6283 geo-tagged web texts were collected at a speed of 0.58 texts per second. The collected texts about built-up areas were transformed into sample data. User’s accuracy of 82.2% was achieved, which is close to that derived from formal expert validation. The preliminary results show that geo-tagged web texts are valuable ancillary data for LC map validation and the proposed approach can improve the efficiency of sample data collection.

  2. Device for collecting chemical compounds and related methods

    Science.gov (United States)

    Scott, Jill R.; Groenewold, Gary S.; Rae, Catherine

    2013-01-01

    A device for sampling chemical compounds from fixed surfaces and related methods are disclosed. The device may include a vacuum source, a chamber and a sorbent material. The device may utilize vacuum extraction to volatilize the chemical compounds from the fixed surfaces so that they may be sorbed by the sorbent material. The sorbent material may then be analyzed using conventional thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS) instrumentation to determine presence of the chemical compounds. The methods may include detecting release and presence of one or more chemical compounds and determining the efficacy of decontamination. The device may be useful in collection and analysis of a variety of chemical compounds, such as residual chemical warfare agents, chemical attribution signatures and toxic industrial chemicals.

  3. Collection and preparation of wet and dry stream-sediment samples

    International Nuclear Information System (INIS)

    Puchlik, K.

    1977-03-01

    Lawrence Livermore Laboratory is responsible for the Hydrogeochemistry and Stream Sediment Reconnaissance (HSSR) program for uranium in the seven far western states. The work thus far has concentrated on the arid to semi-arid regions of the West and this paper discusses the collection and preparation of sediment samples in the Basin and Range province. The sample collection and preparation procedures described here may not be applicable to other parts of the far western states or other areas. These procedures also differ somewhat from those used by the other three laboratories involved in the HSSR program

  4. Efficient free energy calculations by combining two complementary tempering sampling methods.

    Science.gov (United States)

    Xie, Liangxu; Shen, Lin; Chen, Zhe-Ning; Yang, Mingjun

    2017-01-14

    Although energy barriers can be efficiently crossed in the reaction coordinate (RC) guided sampling, this type of method suffers from identification of the correct RCs or requirements of high dimensionality of the defined RCs for a given system. If only the approximate RCs with significant barriers are used in the simulations, hidden energy barriers with small to medium height would exist in other degrees of freedom (DOFs) relevant to the target process and consequently cause the problem of insufficient sampling. To address the sampling in this so-called hidden barrier situation, here we propose an effective approach to combine temperature accelerated molecular dynamics (TAMD), an efficient RC-guided sampling method, with the integrated tempering sampling (ITS), a generalized ensemble sampling method. In this combined ITS-TAMD method, the sampling along the major RCs with high energy barriers is guided by TAMD and the sampling of the rest of the DOFs with lower but not negligible barriers is enhanced by ITS. The performance of ITS-TAMD to three systems in the processes with hidden barriers has been examined. In comparison to the standalone TAMD or ITS approach, the present hybrid method shows three main improvements. (1) Sampling efficiency can be improved at least five times even if in the presence of hidden energy barriers. (2) The canonical distribution can be more accurately recovered, from which the thermodynamic properties along other collective variables can be computed correctly. (3) The robustness of the selection of major RCs suggests that the dimensionality of necessary RCs can be reduced. Our work shows more potential applications of the ITS-TAMD method as the efficient and powerful tool for the investigation of a broad range of interesting cases.

  5. A method of language sampling

    DEFF Research Database (Denmark)

    Rijkhoff, Jan; Bakker, Dik; Hengeveld, Kees

    1993-01-01

    In recent years more attention is paid to the quality of language samples in typological work. Without an adequate sampling strategy, samples may suffer from various kinds of bias. In this article we propose a sampling method in which the genetic criterion is taken as the most important: samples...... created with this method will reflect optimally the diversity of the languages of the world. On the basis of the internal structure of each genetic language tree a measure is computed that reflects the linguistic diversity in the language families represented by these trees. This measure is used...... to determine how many languages from each phylum should be selected, given any required sample size....

  6. Efficiency of Picture Description and Storytelling Methods in Language Sampling According to the Mean Length of Utterance Index

    Directory of Open Access Journals (Sweden)

    Salime Jafari

    2012-10-01

    Full Text Available Background and Aim: Due to limitation of standardized tests for Persian-speakers with language disorders, spontaneous language sampling collection is an important part of assessment of languageprotocol. Therefore, selection of a language sampling method, which will provide information of linguistic competence in a short time, is important. Therefore, in this study, we compared the languagesamples elicited with picture description and storytelling methods in order to determine the effectiveness of the two methods.Methods: In this study 30 first-grade elementary school girls were selected with simple sampling. To investigate picture description method, we used two illustrated stories with four pictures. Languagesamples were collected through storytelling by telling a famous children’s story. To determine the effectiveness of these two methods the two indices of duration of sampling and mean length ofutterance (MLU were compared.Results: There was no significant difference between MLU in description and storytelling methods(p>0.05. However, duration of sampling was shorter in the picture description method than the storytelling method (p<0.05.Conclusion: Findings show that, the two methods of picture description and storytelling have the same potential in language sampling. Since, picture description method can provide language samples with the same complexity in a shorter time than storytelling, it can be used as a beneficial method forclinical purposes.

  7. Pediatric blood sample collection from a pre-existing peripheral intravenous (PIV) catheter.

    Science.gov (United States)

    Braniff, Heather; DeCarlo, Ann; Haskamp, Amy Corey; Broome, Marion E

    2014-01-01

    Aiming to minimize pain in a hospitalized child, the purpose of this observational study was to describe characteristics of blood samples collected from pre-existing peripheral intravenous (PIV) catheters in pediatric patients. One hundred and fifty blood samples were reviewed for number of unusable samples requiring a specimen to be re-drawn. Success of the blood draw and prevalence of the loss of the PIV following blood collection was also measured. Findings included one clotted specimen, success rate of 91.3%, and 1.3% of PIVs becoming non-functional after collection. Obtaining blood specimens from a pre-existing PIV should be considered in a pediatric patient. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Optimal sampling strategies to assess inulin clearance in children by the inulin single-injection method

    NARCIS (Netherlands)

    van Rossum, Lyonne K.; Mathot, Ron A. A.; Cransberg, Karlien; Vulto, Arnold G.

    2003-01-01

    Glomerular filtration rate in patients can be determined by estimating the plasma clearance of inulin with the single-injection method. In this method, a single bolus injection of inulin is administered and several blood samples are collected. For practical and convenient application of this method

  9. Characterization of specimens obtained by different sampling methods for evaluation of periodontal bacteria.

    Science.gov (United States)

    Okada, Ayako; Sogabe, Kaoru; Takeuchi, Hiroaki; Okamoto, Masaaki; Nomura, Yoshiaki; Hanada, Nobuhiro

    2017-12-27

    Quantitative analysis of periodontal bacteria is considered useful for clinical diagnosis, evaluation and assessment of the risk of periodontal disease. The purpose of this study was to compare the effectiveness of sampling of saliva, supragingival and subgingival plaque for evaluation of periodontal bacteria. From each of 12 subjects, i) subgingival plaque was collected from the deepest pocket using a sterile paper point, ii) stimulated whole saliva was collected after chewing gum, and iii) supragingival plaque was collected using a tooth brush. These samples were sent to the medical examination laboratory for quantitative analysis of the counts of three periodontal bacterial species: Porphyromonas gingivalis, Treponema denticola, and Tannerella forsythia. The proportions of these bacteria in subgingival plaque were higher than those in saliva or supragingival plaque, but lower in subgingival plaque than in saliva or supragingival plaque. In several cases, periodontal bacteria were below the levels of detection in subgingival plaque. We concluded that samples taken from subgingival plaque may be more useful for evaluating the proportion of periodontal bacteria in deep pockets than is the case for other samples. Therefore, for evaluation of periodontal bacteria, clinicians should consider the characteristics of the specimens obtained using different sampling methods.

  10. Comparability among four invertebrate sampling methods and two multimetric indexes, Fountain Creek Basin, Colorado, 2010–2012

    Science.gov (United States)

    Bruce, James F.; Roberts, James J.; Zuellig, Robert E.

    2018-05-24

    The U.S. Geological Survey (USGS), in cooperation with Colorado Springs City Engineering and Colorado Springs Utilities, analyzed previously collected invertebrate data to determine the comparability among four sampling methods and two versions (2010 and 2017) of the Colorado Benthic Macroinvertebrate Multimetric Index (MMI). For this study, annual macroinvertebrate samples were collected concurrently (in space and time) at 15 USGS surface-water gaging stations in the Fountain Creek Basin from 2010 to 2012 using four sampling methods. The USGS monitoring project in the basin uses two of the methods and the Colorado Department of Public Health and Environment recommends the other two. These methods belong to two distinct sample types, one that targets single habitats and one that targets multiple habitats. The study results indicate that there are significant differences in MMI values obtained from the single-habitat and multihabitat sample types but methods from each program within each sample type produced comparable values. This study also determined that MMI values calculated by different versions of the Colorado Benthic Macroinvertebrate MMI are indistinguishable. This indicates that the Colorado Department of Public Health and Environment methods are comparable with the USGS monitoring project methods for single-habitat and multihabitat sample types. This report discusses the direct application of the study results to inform the revision of the existing USGS monitoring project in the Fountain Creek Basin.

  11. Analysis of Dust Samples Collected from an In-Service Interim Storage System at the Maine Yankee Nuclear Site.

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Charles R.; Enos, David

    2016-10-01

    In July, 2016, the Electric Power Research Institute and industry partners performed a field test at the Maine Yankee Nuclear Site, located near Wiscasset, Maine. The primary goal of the field test was to evaluate the use of robots in surveying the surface of an in-service interim storage canister within an overpack; however, as part of the demonstration, dust and soluble salt samples were collected from horizontal surfaces within the interim storage system. The storage system is a vertical system made by NAC International, consisting of a steel-lined concrete overpack containing a 304 stainless steel (SS) welded storage canister. The canister did not contain spent fuel but rather greater-than-class-C waste, which did not generate significant heat, limiting airflow through the storage system. The surfaces that were sampled for deposits included the top of the shield plug, the side of the canister, and a shelf at the bottom of the overpack, just below the level of the pillar on which the canister sits. The samples were sent to Sandia National Laboratories for analysis. This report summarizes the results of those analyses. Because the primary goal of the field test was to evaluate the use of robots in surveying the surface of the canister within the overpack, collection of dust samples was carried out in a qualitative fashion, using paper filters and sponges as the sampling media. The sampling focused mostly on determining the composition of soluble salts present in the dust. It was anticipated that a wet substrate would more effectively extract soluble salts from the surface that was sampled, so both the sponges and the filter paper were wetted prior to being applied to the surface of the metal. Sampling was accomplished by simply pressing the damp substrate against the metal surface for two minutes, and then removing it. It is unlikely that the sampling method quantitatively collected dust or salts from the metal surface; however, both substrates did extract a

  12. A method for sampling microbial aerosols using high altitude balloons.

    Science.gov (United States)

    Bryan, N C; Stewart, M; Granger, D; Guzik, T G; Christner, B C

    2014-12-01

    Owing to the challenges posed to microbial aerosol sampling at high altitudes, very little is known about the abundance, diversity, and extent of microbial taxa in the Earth-atmosphere system. To directly address this knowledge gap, we designed, constructed, and tested a system that passively samples aerosols during ascent through the atmosphere while tethered to a helium-filled latex sounding balloon. The sampling payload is ~ 2.7 kg and comprised of an electronics box and three sampling chambers (one serving as a procedural control). Each chamber is sealed with retractable doors that can be commanded to open and close at designated altitudes. The payload is deployed together with radio beacons that transmit GPS coordinates (latitude, longitude and altitude) in real time for tracking and recovery. A cut mechanism separates the payload string from the balloon at any desired altitude, returning all equipment safely to the ground on a parachute. When the chambers are opened, aerosol sampling is performed using the Rotorod® collection method (40 rods per chamber), with each rod passing through 0.035 m3 per km of altitude sampled. Based on quality control measurements, the collection of ~ 100 cells rod(-1) provided a 3-sigma confidence level of detection. The payload system described can be mated with any type of balloon platform and provides a tool for characterizing the vertical distribution of microorganisms in the troposphere and stratosphere. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Determination of 36Cl in environmental samples collected in the JCO by AMS

    International Nuclear Information System (INIS)

    Seki, R.; Tsukuba Univ., Ibaraki; Arai, D.; Nagashima, Y.; Takahashi, T.; Matsuhiro, T.; Imanaka, T.

    2003-01-01

    Long-lived chlorine, 36 Cl (T 1/2 = 301,000 y) in environmental samples has been measured by the AMS system installed in Tandem Accelerator Center, University of Tsukuba. A tri-carbon-molecular 12 C 3 - pilot beam method is used to stabilize the terminal voltage of the tandem. A small amount of pure carbon graphite is well mixed into a AgCl target material for creating Cl - and 12 C 3 - in the ion source. A 36 S isobaric interference in the system is eliminated to determine 36 Cl in environmental samples by chemical procedure. Some samples containing chlorine such as soil, chemical reagents and table salt have been collected in the JCO criticality accident site and analyzed to detect neutron-induced 36 Cl. The experimental result has been compared with a theoretical calculation. (author)

  14. SWOT ANALYSIS ON SAMPLING METHOD

    Directory of Open Access Journals (Sweden)

    CHIS ANCA OANA

    2014-07-01

    Full Text Available Audit sampling involves the application of audit procedures to less than 100% of items within an account balance or class of transactions. Our article aims to study audit sampling in audit of financial statements. As an audit technique largely used, in both its statistical and nonstatistical form, the method is very important for auditors. It should be applied correctly for a fair view of financial statements, to satisfy the needs of all financial users. In order to be applied correctly the method must be understood by all its users and mainly by auditors. Otherwise the risk of not applying it correctly would cause loose of reputation and discredit, litigations and even prison. Since there is not a unitary practice and methodology for applying the technique, the risk of incorrectly applying it is pretty high. The SWOT analysis is a technique used that shows the advantages, disadvantages, threats and opportunities. We applied SWOT analysis in studying the sampling method, from the perspective of three players: the audit company, the audited entity and users of financial statements. The study shows that by applying the sampling method the audit company and the audited entity both save time, effort and money. The disadvantages of the method are difficulty in applying and understanding its insight. Being largely used as an audit method and being a factor of a correct audit opinion, the sampling method’s advantages, disadvantages, threats and opportunities must be understood by auditors.

  15. When rare is just a matter of sampling: unexpected dominance of clubtail dragonflies (Odonata, Gomphidae through different collecting methods at Parque Nacional da Serra do Cipó, Minas Gerais State, Brazil

    Directory of Open Access Journals (Sweden)

    Marcus Vinícius Oliveira de Almeida

    2013-12-01

    Full Text Available When rare is just a matter of sampling: Unexpected dominance of clubtail dragonflies (Odonata, Gomphidae through different collecting methods at Parque Nacional da Serra do Cipó, Minas Gerais State, Brazil. Capture of dragonfly adults during two short expeditions to Parque Nacional da Serra do Cipó, Minas Gerais State, using three distinct collecting methodsaerial nets, Malaise and light sheet trapsis reported. The results are outstanding due the high number of species of Gomphidae (7 out of 26 Odonata species, including a new species of Cyanogomphus Selys, 1873, obtained by two non-traditional collecting methods. Because active collecting with aerial nets is the standard approach for dragonfly inventories, we discuss some aspects of the use of traps, comparing our results with those in the literature, suggesting they should be used as complementary methods in faunistic studies. Furthermore, Zonophora campanulata annulata Belle, 1983 is recorded for the first time from Minas Gerais State and taxonomic notes about Phyllogomphoides regularis (Selys, 1873 and Progomphus complicatus Selys, 1854 are also given.

  16. PhyloChip™ microarray comparison of sampling methods used for coral microbial ecology

    Science.gov (United States)

    Kellogg, Christina A.; Piceno, Yvette M.; Tom, Lauren M.; DeSantis, Todd Z.; Zawada, David G.; Andersen, Gary L.

    2012-01-01

    Interest in coral microbial ecology has been increasing steadily over the last decade, yet standardized methods of sample collection still have not been defined. Two methods were compared for their ability to sample coral-associated microbial communities: tissue punches and foam swabs, the latter being less invasive and preferred by reef managers. Four colonies of star coral, Montastraea annularis, were sampled in the Dry Tortugas National Park (two healthy and two with white plague disease). The PhyloChip™ G3 microarray was used to assess microbial community structure of amplified 16S rRNA gene sequences. Samples clustered based on methodology rather than coral colony. Punch samples from healthy and diseased corals were distinct. All swab samples clustered closely together with the seawater control and did not group according to the health state of the corals. Although more microbial taxa were detected by the swab method, there is a much larger overlap between the water control and swab samples than punch samples, suggesting some of the additional diversity is due to contamination from water absorbed by the swab. While swabs are useful for noninvasive studies of the coral surface mucus layer, these results show that they are not optimal for studies of coral disease.

  17. Sampling system and method

    Science.gov (United States)

    Decker, David L.; Lyles, Brad F.; Purcell, Richard G.; Hershey, Ronald Lee

    2013-04-16

    The present disclosure provides an apparatus and method for coupling conduit segments together. A first pump obtains a sample and transmits it through a first conduit to a reservoir accessible by a second pump. The second pump further conducts the sample from the reservoir through a second conduit.

  18. Impact of collection method on assessment of semen HIV RNA viral load.

    Directory of Open Access Journals (Sweden)

    Brendan J W Osborne

    Full Text Available The blood HIV RNA viral load is the best-defined predictor of HIV transmission, in part due to ease of measurement and the correlation of blood and genital tract (semen or cervico-vaginal viral load, although recent studies found semen HIV RNA concentration to be a stronger predictor of HIV transmission. There is currently no standardized method for semen collection when measuring HIV RNA concentration. Therefore, we compared two collection techniques in order to study of the impact of antiretroviral therapy on the semen viral load.Semen was collected by masturbation from HIV-infected, therapy-naïve men who have sex with men (MSM either undiluted (Visit 1 or directly into transport medium (Visit 2. Seminal plasma was then isolated, and the HIV RNA concentration obtained with each collection technique was measured and corrected for dilution if necessary. Collection of semen directly into transport medium resulted in a median HIV RNA viral load that was 0.4 log10 higher than undiluted samples.The method of semen collection is an important consideration when quantifying the HIV RNA viral load in this compartment.

  19. A method of language sampling

    DEFF Research Database (Denmark)

    Rijkhoff, Jan; Bakker, Dik; Hengeveld, Kees

    1993-01-01

    In recent years more attention is paid to the quality of language samples in typological work. Without an adequate sampling strategy, samples may suffer from various kinds of bias. In this article we propose a sampling method in which the genetic criterion is taken as the most important: samples...... to determine how many languages from each phylum should be selected, given any required sample size....

  20. Comparison of DNA preservation methods for environmental bacterial community samples.

    Science.gov (United States)

    Gray, Michael A; Pratte, Zoe A; Kellogg, Christina A

    2013-02-01

    Field collections of environmental samples, for example corals, for molecular microbial analyses present distinct challenges. The lack of laboratory facilities in remote locations is common, and preservation of microbial community DNA for later study is critical. A particular challenge is keeping samples frozen in transit. Five nucleic acid preservation methods that do not require cold storage were compared for effectiveness over time and ease of use. Mixed microbial communities of known composition were created and preserved by DNAgard(™), RNAlater(®), DMSO-EDTA-salt (DESS), FTA(®) cards, and FTA Elute(®) cards. Automated ribosomal intergenic spacer analysis and clone libraries were used to detect specific changes in the faux communities over weeks and months of storage. A previously known bias in FTA(®) cards that results in lower recovery of pure cultures of Gram-positive bacteria was also detected in mixed community samples. There appears to be a uniform bias across all five preservation methods against microorganisms with high G + C DNA. Overall, the liquid-based preservatives (DNAgard(™), RNAlater(®), and DESS) outperformed the card-based methods. No single liquid method clearly outperformed the others, leaving method choice to be based on experimental design, field facilities, shipping constraints, and allowable cost. © 2012 Federation of European Microbiological Societies. Published by Blackwell Publishing Ltd. All rights reserved.

  1. Next Generation Offline Approaches to Trace Gas-Phase Organic Compound Speciation: Sample Collection and Analysis

    Science.gov (United States)

    Sheu, R.; Marcotte, A.; Khare, P.; Ditto, J.; Charan, S.; Gentner, D. R.

    2017-12-01

    Intermediate-volatility and semi-volatile organic compounds (I/SVOCs) are major precursors to secondary organic aerosol, and contribute to tropospheric ozone formation. Their wide volatility range, chemical complexity, behavior in analytical systems, and trace concentrations present numerous hurdles to characterization. We present an integrated sampling-to-analysis system for the collection and offline analysis of trace gas-phase organic compounds with the goal of preserving and recovering analytes throughout sample collection, transport, storage, and thermal desorption for accurate analysis. Custom multi-bed adsorbent tubes are used to collect samples for offline analysis by advanced analytical detectors. The analytical instrumentation comprises an automated thermal desorption system that introduces analytes from the adsorbent tubes into a gas chromatograph, which is coupled with an electron ionization mass spectrometer (GC-EIMS) and other detectors. In order to optimize the collection and recovery for a wide range of analyte volatility and functionalization, we evaluated a variety of commercially-available materials, including Res-Sil beads, quartz wool, glass beads, Tenax TA, and silica gel. Key properties for optimization include inertness, versatile chemical capture, minimal affinity for water, and minimal artifacts or degradation byproducts; these properties were assessed with a diverse mix of traditionally-measured and functionalized analytes. Along with a focus on material selection, we provide recommendations spanning the entire sampling-and-analysis process to improve the accuracy of future comprehensive I/SVOC measurements, including oxygenated and other functionalized I/SVOCs. We demonstrate the performance of our system by providing results on speciated VOCs-SVOCs from indoor, outdoor, and chamber studies that establish the utility of our protocols and pave the way for precise laboratory characterization via a mix of detection methods.

  2. Human blood RNA stabilization in samples collected and transported for a large biobank

    Science.gov (United States)

    2012-01-01

    Background The Norwegian Mother and Child Cohort Study (MoBa) is a nation-wide population-based pregnancy cohort initiated in 1999, comprising more than 108.000 pregnancies recruited between 1999 and 2008. In this study we evaluated the feasibility of integrating RNA analyses into existing MoBa protocols. We compared two different blood RNA collection tube systems – the PAXgene™ Blood RNA system and the Tempus™ Blood RNA system - and assessed the effects of suboptimal blood volumes in collection tubes and of transportation of blood samples by standard mail. Endpoints to characterize the samples were RNA quality and yield, and the RNA transcript stability of selected genes. Findings High-quality RNA could be extracted from blood samples stabilized with both PAXgene and Tempus tubes. The RNA yields obtained from the blood samples collected in Tempus tubes were consistently higher than from PAXgene tubes. Higher RNA yields were obtained from cord blood (3 – 4 times) compared to adult blood with both types of tubes. Transportation of samples by standard mail had moderate effects on RNA quality and RNA transcript stability; the overall RNA quality of the transported samples was high. Some unexplained changes in gene expression were noted, which seemed to correlate with suboptimal blood volumes collected in the tubes. Temperature variations during transportation may also be of some importance. Conclusions Our results strongly suggest that special collection tubes are necessary for RNA stabilization and they should be used for establishing new biobanks. We also show that the 50,000 samples collected in the MoBa biobank provide RNA of high quality and in sufficient amounts to allow gene expression analyses for studying the association of disease with altered patterns of gene expression. PMID:22988904

  3. Chemicals of emerging concern in water and bottom sediment in Great Lakes areas of concern, 2010 to 2011-Collection methods, analyses methods, quality assurance, and data

    Science.gov (United States)

    Lee, Kathy E.; Langer, Susan K.; Menheer, Michael A.; Foreman, William T.; Furlong, Edward T.; Smith, Steven G.

    2012-01-01

    The U.S. Geological Survey (USGS) cooperated with the U.S. Environmental Protection Agency and the U.S. Fish and Wildlife Service on a study to identify the occurrence of chemicals of emerging concern (CECs) in water and bottom-sediment samples collected during 2010–11 at sites in seven areas of concern (AOCs) throughout the Great Lakes. Study sites include tributaries to the Great Lakes in AOCs located near Duluth, Minn.; Green Bay, Wis.; Roches­ter, N.Y.; Detroit, Mich.; Toledo, Ohio; Milwaukee, Wis.; and Ashtabula, Ohio. This report documents the collection meth­ods, analyses methods, quality-assurance data and analyses, and provides the data for this study. Water and bottom-sediment samples were analyzed at the USGS National Water Quality Laboratory in Denver, Colo., for a broad suite of CECs. During this study, 135 environmental and 23 field dupli­cate samples of surface water and wastewater effluent, 10 field blank water samples, and 11 field spike water samples were collected and analyzed. Sixty-one of the 69 wastewater indicator chemicals (laboratory method 4433) analyzed were detected at concentrations ranging from 0.002 to 11.2 micrograms per liter. Twenty-eight of the 48 pharmaceuticals (research method 8244) analyzed were detected at concentrations ranging from 0.0029 to 22.0 micro­grams per liter. Ten of the 20 steroid hormones and sterols analyzed (research method 4434) were detected at concentrations ranging from 0.16 to 10,000 nanograms per liter. During this study, 75 environmental, 13 field duplicate samples, and 9 field spike samples of bottom sediment were collected and analyzed for a wide variety of CECs. Forty-seven of the 57 wastewater indicator chemicals (laboratory method 5433) analyzed were detected at concentrations ranging from 0.921 to 25,800 nanograms per gram. Seventeen of the 20 steroid hormones and sterols (research method 6434) analyzed were detected at concentrations ranging from 0.006 to 8,921 nanograms per gram. Twelve of

  4. Bioassessment tools in novel habitats: an evaluation of indices and sampling methods in low-gradient streams in California.

    Science.gov (United States)

    Mazor, Raphael D; Schiff, Kenneth; Ritter, Kerry; Rehn, Andy; Ode, Peter

    2010-08-01

    Biomonitoring programs are often required to assess streams for which assessment tools have not been developed. For example, low-gradient streams (slopeindices in the state were developed in high-gradient systems. This study evaluated the performance of three sampling methods [targeted riffle composite (TRC), reach-wide benthos (RWB), and the margin-center-margin modification of RWB (MCM)] and two indices [the Southern California Index of Biotic Integrity (SCIBI) and the ratio of observed to expected taxa (O/E)] in low-gradient streams in California for application in this habitat type. Performance was evaluated in terms of efficacy (i.e., ability to collect enough individuals for index calculation), comparability (i.e., similarity of assemblages and index scores), sensitivity (i.e., responsiveness to disturbance), and precision (i.e., ability to detect small differences in index scores). The sampling methods varied in the degree to which they targeted macroinvertebrate-rich microhabitats, such as riffles and vegetated margins, which may be naturally scarce in low-gradient streams. The RWB method failed to collect sufficient numbers of individuals (i.e., >or=450) to calculate the SCIBI in 28 of 45 samples and often collected fewer than 100 individuals, suggesting it is inappropriate for low-gradient streams in California; failures for the other methods were less common (TRC, 16 samples; MCM, 11 samples). Within-site precision, measured as the minimum detectable difference (MDD) was poor but similar across methods for the SCIBI (ranging from 19 to 22). However, RWB had the lowest MDD for O/E scores (0.20 versus 0.24 and 0.28 for MCM and TRC, respectively). Mantel correlations showed that assemblages were more similar within sites among methods than within methods among sites, suggesting that the sampling methods were collecting similar assemblages of organisms. Statistically significant disagreements among methods were not detected, although O/E scores were higher

  5. Cortisol and prolactin concentrations during repeated blood sample collection from freely moving, mouse-sized mammals (Phodopus spp.).

    Science.gov (United States)

    Reburn, C J; Wynne-Edwards, K E

    2000-04-01

    Validation of a method for obtaining blood samples that does not change cortisol or prolactin concentrations yet allows serial blood samples to be collected from animals under anesthesia, without prior handling, from freely interacting social groups of small mammals. Results from five experiments are reported. Male dwarf hamsters (Phodopus spp.) were housed in modified home cages under continuous flow of compressed air that could be switched to isoflurane in O2 vehicle without approaching the cages. Dwarf hamsters respond to manual restraint with behavioral distress and increase in the concentration of the dominant glucocorticoid, cortisol, and decrease in prolactin concentration. Both effects are evident within one minute. In contrast, when this new method was used, neither cortisol nor prolactin changed in response to repeated sample collection (up to 8 successive samples at 2 hour intervals), prolonged isoflurane exposure, or substantial blood volume reduction (30%). Prolactin concentration was suppressed and cortisol concentration was increased in response to stimuli from other hamsters tested without anesthesia. Suppression of prolactin concentration was graded in response to the degree of stress and equaled the pharmacologic reduction caused by bromocryptine mesylate (50 microg of CB154 x 3 days). The technique is superior to alternatives for studies of behavioral endocrinology of freely interacting small mammals.

  6. Effect Of Instructions About The Method Of Urine Collection And ...

    African Journals Online (AJOL)

    Despite the explanation, 15(23.1%) of the patients collected the urine samples wrongly and 44(67.7%) stored the samples for longer than one hour. Significant bacteriuria was more prevalent in 74.2% of patients who submitted their urine samples more than one hour after collection. Communication skill is important and ...

  7. GAINS IN PERFORMANCE OF DIFFERENT METHODS OF COLLECTING ENTOMOLOGICAL MATERIALS IN ENVIRONMENTAL AND FAUNAL STUDIES ON COLEOPTERA

    Directory of Open Access Journals (Sweden)

    B. N. Saypulaeva

    2015-01-01

    Full Text Available The aim is to study the effectiveness of methods of collecting entomological materials for further ecological and faunal studies as well as to gain the main evidence in ecological and faunal studies carried out in the field. Collection of the evidence in the field is necessary for the identification of species composition and to study such aspects as the distribution of species, confinement of species to certain habitats, relations with the food objects (trophism, climate, soil and orographic environmental factors.Methodology. We have used the traditional methods of collection (hand picking, pitfall traps, pitfall traps with increased light, light traps, processing and determination of materials. In recent years, the method of collection of soil invertebrates has introduced an innovation. In expeditionary studies in the island of Tyuleny new ways have been tested of using pitfall traps equipped with an incandescent light source. They provide a higher collection efficiency of Entomological materials. List of species composition of the discussed fauna has been composed by modern taxonomy with the use of directories.Results. We have made a comparative analysis of the effectiveness of different methods of collecting entomological materials on Coleoptera (Carabidae, Scarabaeidae, Elateridae, Tenebrionidae for environmental and faunal studies in the area of Irganayskaya arid basin of intramontane Dagestan. Not all species, registered in the studied habitat, have been identified by methods of soil sampling and pitfall traps. The greatest number of species has been identified by manual collection, and the least by soil sampling. The paper shows the effectiveness of different methods of collecting entomofauna against individual families and species of the groups studied.

  8. rCBF measurement by one-point venous sampling with the ARG method

    International Nuclear Information System (INIS)

    Yoshida, Nobuhiro; Okamoto, Toshiaki; Takahashi, Hidekado; Hattori, Teruo

    1997-01-01

    We investigated the possibility of using venous blood sampling instead of arterial blood sampling for the current method of ARG (autoradiography) used to determine regional cerebral blood flow (rCBF) on the basis of one session of arterial blood sampling and SPECT. For this purpose, the ratio of the arterial blood radioactivity count to the venous blood radioactivity count, the coefficient of variation, and the correlation and differences between arterial blood-based rCBF and venous blood-based rCBF were analyzed. The coefficient of variation was lowest (4.1%) 20 minutes after injection into the dorsum manus. When the relationship between venous and arterial blood counts was analyzed, arterial blood counts correlated well with venous blood counts collected at the dorsum manus 20 or 30 minutes after intravenous injection and with venous blood counts collected at the wrist 20 minutes after intravenous injection (r=0.97 or higher). The difference from rCBF determined on the basis of arterial blood was smallest (0.7) for rCBF determined on the basis of venous blood collected at the dorsum manus 20 minutes after intravenous injection. (author)

  9. Self-consistent collective coordinate method for large amplitude collective motions

    International Nuclear Information System (INIS)

    Sakata, F.; Hashimoto, Y.; Marumori, T.; Une, T.

    1982-01-01

    A recent development of the self-consistent collective coordinate method is described. The self-consistent collective coordinate method was proposed on the basis of the fundamental principle called the invariance principle of the Schroedinger equation. If this is formulated within a framework of the time dependent Hartree Fock (TDHF) theory, a classical version of the theory is obtained. A quantum version of the theory is deduced by formulating it within a framework of the unitary transformation method with auxiliary bosons. In this report, the discussion is concentrated on a relation between the classical theory and the quantum theory, and an applicability of the classical theory. The aim of the classical theory is to extract a maximally decoupled collective subspace out of a huge dimensional 1p - 1h parameter space introduced by the TDHF theory. An intimate similarity between the classical theory and a full quantum boson expansion method (BEM) was clarified. Discussion was concentrated to a simple Lipkin model. Then a relation between the BEM and the unitary transformation method with auxiliary bosons was discussed. It became clear that the quantum version of the theory had a strong relation to the BEM, and that the BEM was nothing but a quantum analogue of the present classical theory. The present theory was compared with the full TDHF calculation by using a simple model. (Kato, T.)

  10. Blood venous sample collection: Recommendations overview and a checklist to improve quality.

    Science.gov (United States)

    Giavarina, Davide; Lippi, Giuseppe

    2017-07-01

    The extra-analytical phases of the total testing process have substantial impact on managed care, as well as an inherent high risk of vulnerability to errors which is often greater than that of the analytical phase. The collection of biological samples is a crucial preanalytical activity. Problems or errors occurring shortly before, or soon after, this preanalytical step may impair sample quality and characteristics, or else modify the final results of testing. The standardization of fasting requirements, rest, patient position and psychological state of the patient are therefore crucial for mitigating the impact of preanalytical variability. Moreover, the quality of materials used for collecting specimens, along with their compatibility, can guarantee sample quality and persistence of chemical and physical characteristics of the analytes over time, so safeguarding the reliability of testing. Appropriate techniques and sampling procedures are effective to prevent problems such as hemolysis, undue clotting in the blood tube, draw of insufficient sample volume and modification of analyte concentration. An accurate identification of both patient and blood samples is a key priority as for other healthcare activities. Good laboratory practice and appropriate training of operators, by specifically targeting collection of biological samples, blood in particular, may greatly improve this issue, thus lowering the risk of errors and their adverse clinical consequences. The implementation of a simple and rapid check-list, including verification of blood collection devices, patient preparation and sampling techniques, was found to be effective for enhancing sample quality and reducing some preanalytical errors associated with these procedures. The use of this tool, along with implementation of objective and standardized systems for detecting non-conformities related to unsuitable samples, can be helpful for standardizing preanalytical activities and improving the quality of

  11. Determination of mercury in ash and soil samples by oxygen flask combustion method-Cold vapor atomic fluorescence spectrometry (CVAFS)

    International Nuclear Information System (INIS)

    Geng Wenhua; Nakajima, Tsunenori; Takanashi, Hirokazu; Ohki, Akira

    2008-01-01

    A simple method was developed for the determination of mercury (Hg) in coal fly ash (CFA), waste incineration ash (WIA), and soil by use of oxygen flask combustion (OFC) followed by cold vapor atomic fluorescence spectrometry (CVAFS). A KMnO 4 solution was used as an absorbent in the OFC method, and the sample containing a combustion agent and an ash or soil sample was combusted by the OFC method. By use of Hg-free graphite as the combustion agent, the determination of Hg in ash and soil was successfully carried out; the Hg-free graphite was prepared by use of a mild pyrolysis procedure at 500 deg. C. For six certified reference materials (three CFA samples and three soil samples), the values of Hg obtained by this method were in good agreement with the certified or reference values. In addition, real samples including nine CFAs collected from some coal-fired power plants, five WIAs collected from waste incineration plants, and two soils were analyzed by the present method, and the data were compared to those from microwave-acid digestion (MW-AD) method

  12. Sterile Reverse Osmosis Water Combined with Friction Are Optimal for Channel and Lever Cavity Sample Collection of Flexible Duodenoscopes

    Directory of Open Access Journals (Sweden)

    Michelle J. Alfa

    2017-11-01

    Full Text Available IntroductionSimulated-use buildup biofilm (BBF model was used to assess various extraction fluids and friction methods to determine the optimal sample collection method for polytetrafluorethylene channels. In addition, simulated-use testing was performed for the channel and lever cavity of duodenoscopes.Materials and methodsBBF was formed in polytetrafluorethylene channels using Enterococcus faecalis, Escherichia coli, and Pseudomonas aeruginosa. Sterile reverse osmosis (RO water, and phosphate-buffered saline with and without Tween80 as well as two neutralizing broths (Letheen and Dey–Engley were each assessed with and without friction. Neutralizer was added immediately after sample collection and samples concentrated using centrifugation. Simulated-use testing was done using TJF-Q180V and JF-140F Olympus duodenoscopes.ResultsDespite variability in the bacterial CFU in the BBF model, none of the extraction fluids tested were significantly better than RO. Borescope examination showed far less residual material when friction was part of the extraction protocol. The RO for flush-brush-flush (FBF extraction provided significantly better recovery of E. coli (p = 0.02 from duodenoscope lever cavities compared to the CDC flush method.Discussion and conclusionWe recommend RO with friction for FBF extraction of the channel and lever cavity of duodenoscopes. Neutralizer and sample concentration optimize recovery of viable bacteria on culture.

  13. Perpendicular distance sampling: an alternative method for sampling downed coarse woody debris

    Science.gov (United States)

    Michael S. Williams; Jeffrey H. Gove

    2003-01-01

    Coarse woody debris (CWD) plays an important role in many forest ecosystem processes. In recent years, a number of new methods have been proposed to sample CWD. These methods select individual logs into the sample using some form of unequal probability sampling. One concern with most of these methods is the difficulty in estimating the volume of each log. A new method...

  14. Optimum collective submanifold in resonant cases by the self-consistent collective-coordinate method for large-amplitude collective motion

    International Nuclear Information System (INIS)

    Hashimoto, Y.; Marumori, T.; Sakata, F.

    1987-01-01

    With the purpose of clarifying characteristic difference of the optimum collective submanifolds in nonresonant and resonant cases, we develop an improved method of solving the basic equations of the self-consistent collective-coordinate (SCC) method for large-amplitude collective motion. It is shown that, in the resonant cases, there inevitably arise essential coupling terms which break the maximal-decoupling property of the collective motion, and we have to extend the optimum collective submanifold so as to properly treat the degrees of freedom which bring about the resonances

  15. Sampling method of environmental radioactivity monitoring

    International Nuclear Information System (INIS)

    1984-01-01

    This manual provides sampling methods of environmental samples of airborne dust, precipitated dust, precipitated water (rain or snow), fresh water, soil, river sediment or lake sediment, discharged water from a nuclear facility, grains, tea, milk, pasture grass, limnetic organisms, daily diet, index organisms, sea water, marine sediment, marine organisms, and that for tritium and radioiodine determination for radiation monitoring from radioactive fallout or radioactivity release by nuclear facilities. This manual aims at the presentation of standard sampling procedures for environmental radioactivity monitoring regardless of monitoring objectives, and shows preservation method of environmental samples acquired at the samplingpoint for radiation counting for those except human body. Sampling techniques adopted in this manual is decided by the criteria that they are suitable for routine monitoring and any special skillfulness is not necessary. Based on the above-mentioned principle, this manual presents outline and aims of sampling, sampling position or object, sampling quantity, apparatus, equipment or vessel for sampling, sampling location, sampling procedures, pretreatment and preparation procedures of a sample for radiation counting, necessary recording items for sampling and sample transportation procedures. Special attention is described in the chapter of tritium and radioiodine because these radionuclides might be lost by the above-mentioned sample preservation method for radiation counting of less volatile radionuclides than tritium or radioiodine. (Takagi, S.)

  16. Activity Concentration for Surface Soil Samples Collected from Arrant, Qena, Egypt

    International Nuclear Information System (INIS)

    Harb, S.; Salahel Din, K.; Abbady, A.; Moustafa, M.

    2010-01-01

    Soil samples were collected from four regions from Armant area. Qena, Upper Egypt for measure their natural radioactivity concentrations due to Ra-226, Th-232 and K-40 radionuclides. Thirty-Four surface soil samples were analyzed by using low-level gamma-spectrometric analysis. The average activity concentration for Ra-226 in (Bq/kg) in the collected soil samples were found to be 27.3 ±3.2, 11.4±1.09, 10.6±1.2, and 11.4±1.02 while the average value for Th-232 were 15.1±1.4, 11.1±0.77, 10.8 ± 0.72 and 11.1 ± 0.8 (Bq/kg) for soil samples from North, South, West and East. The corresponding average values for K-40 were 521.4±16.8, 463±14.8, 488.9±15.6 and 344.5±10.7 (Bq/kg), respectively. Based on radionuclides concentration in surface soil samples the radiological effects can be assessed

  17. Collection evaluation in University libraries (II. Methods based on collection use

    Directory of Open Access Journals (Sweden)

    Àngels Massísimo i Sánchez de Boado

    2004-01-01

    Full Text Available This is our second paper devoted to the collection evaluation in the university libraries. Seven methods are described, based on collection use. Their advantages and disadvantages are discussed, as well as their usefulness for a range of library types

  18. An economic passive sampling method to detect particulate pollutants using magnetic measurements.

    Science.gov (United States)

    Cao, Liwan; Appel, Erwin; Hu, Shouyun; Ma, Mingming

    2015-10-01

    Identifying particulate matter (PM) emitted from industrial processes into the atmosphere is an important issue in environmental research. This paper presents a passive sampling method using simple artificial samplers that maintains the advantage of bio-monitoring, but overcomes some of its disadvantages. The samplers were tested in a heavily polluted area (Linfen, China) and compared to results from leaf samples. Spatial variations of magnetic susceptibility from artificial passive samplers and leaf samples show very similar patterns. Scanning electron microscopy suggests that the collected PM are mostly in the range of 2-25 μm; frequent occurrence of spherical shape indicates industrial combustion dominates PM emission. Magnetic properties around power plants show different features than other plants. This sampling method provides a suitable and economic tool for semi-quantifying temporal and spatial distribution of air quality; they can be installed in a regular grid and calibrate the weight of PM. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Methods of human body odor sampling: the effect of freezing.

    Science.gov (United States)

    Lenochova, Pavlina; Roberts, S Craig; Havlicek, Jan

    2009-02-01

    Body odor sampling is an essential tool in human chemical ecology research. However, methodologies of individual studies vary widely in terms of sampling material, length of sampling, and sample processing. Although these differences might have a critical impact on results obtained, almost no studies test validity of current methods. Here, we focused on the effect of freezing samples between collection and use in experiments involving body odor perception. In 2 experiments, we tested whether axillary odors were perceived differently by raters when presented fresh or having been frozen and whether several freeze-thaw cycles affected sample quality. In the first experiment, samples were frozen for 2 weeks, 1 month, or 4 months. We found no differences in ratings of pleasantness, attractiveness, or masculinity between fresh and frozen samples. Similarly, almost no differences between repeatedly thawed and fresh samples were found. We found some variations in intensity; however, this was unrelated to length of storage. The second experiment tested differences between fresh samples and those frozen for 6 months. Again no differences in subjective ratings were observed. These results suggest that freezing has no significant effect on perceived odor hedonicity and that samples can be reliably used after storage for relatively long periods.

  20. Methods for collection and analysis of geopressured geothermal and oil field waters

    Energy Technology Data Exchange (ETDEWEB)

    Lico, M.S.; Kharaka, Y.K.; Carothers, W.W.; Wright, V.A.

    1982-01-01

    Present methods are described for the collection, preservation, and chemical analysis of waters produced from geopressured geothermal and petroleum wells. Detailed procedures for collection include precautions and equipment necessary to ensure that the sample is representative of the water produced. Procedures for sample preservation include filtration, acidification, dilution for silica, methyl isobutyl ketone (MIBK) extraction of aluminum, addition of potassium permanganate to preserve mercury, and precipitation of carbonate species as strontium carbonate for stable carbon isotopes and total dissolved carbonate analysis. Characteristics determined at the well site are sulfide, pH, ammonia, and conductivity. Laboratory procedures are given for the analysis of lithium, sodium, potassium, rubidium, cesium, magnesium, calcium, strontium, barium, iron, manganese, zinc, lead, aluminum, and mercury by atomic absorption and flame emission spectroscopy. Chloride is determined by silver nitrate titration and fluoride by ion-specific electrode. Bromide and iodide concentrations are determined by the hypochlorite oxidation method. Sulfate is analyzed by titration using barium chloride with thorin indicator after pretreatment with alumina. Boron and silica are determined colorimetrically by the carmine and molybdate-blue methods, respectively. Aliphatic acid anions (C/sub 2/ through C/sub 5/) are determined by gas chromatography after separation and concentration in a chloroform-butanol mixture.

  1. Methods for collection and analysis of geopressured geothermal and oil field waters

    Science.gov (United States)

    Lico, Michael S.; Kharaka, Yousif K.; Carothers, William W.; Wright, Victoria A.

    1982-01-01

    Present methods are described for the collection, preservation, and chemical analysis of waters produced from geopressured geothermal and petroleum wells. Detailed procedures for collection include precautions and equipment necessary to ensure that the sample is representative of the water produced. Procedures for sample preservation include filtration, acidification, dilution for silica, methyl isobutyl ketone (MIBK) extraction of aluminum, addition of potassium permanganate to preserve mercury, and precipitation of carbonate species as strontium carbonate for stable carbon isotopes and total dissolved carbonate analysis. Characteristics determined at the well site are sulfide, pH, ammonia, and conductivity. Laboratory procedures are given for the analysis of lithium, sodium, potassium, rubidium, cesium, magnesium, calcium, strontium, barium, iron, manganese, zinc, lead, aluminum, .and mercury by atomic absorption and flame emission spectroscopy. Chloride is determined by silver nitrate titration and fluoride by ion-specific electrode. Bromide and iodide concentrations are determined by the hypochlorite oxidation method. Sulfate is analyzed by titration using barium chloride with thorin indicator after pretreatment with alumina. Boron and silica are determined colorimetrically by the carmine and molybdate-blue methods, respectively. Aliphatic acid anions (C2 through C5) are determined by gas chromatography after separation and concentration in a chloroform-butanol mixture.

  2. Equipment for collecting samples of radioactive solutions; Installation de prelevements d'echantillons de solutions radioactives

    Energy Technology Data Exchange (ETDEWEB)

    Raggenbass, A.; Fradin, J.; Joubert, G.

    1958-12-03

    The authors present an equipment aimed at collecting samples of fission products to perform radio-chemical analysis. As the sample must have a total activity between 1 and 50 micro-Curie, this installation comprises a sampling system and a dilution device which aims at bringing the sample to the suitable activity. Samples are collected by means of needles. The sample reproducibility is discussed. The dilution device is described.

  3. Unbiased proteomics analysis demonstrates significant variability in mucosal immune factor expression depending on the site and method of collection.

    Directory of Open Access Journals (Sweden)

    Kenzie M Birse

    Full Text Available Female genital tract secretions are commonly sampled by lavage of the ectocervix and vaginal vault or via a sponge inserted into the endocervix for evaluating inflammation status and immune factors critical for HIV microbicide and vaccine studies. This study uses a proteomics approach to comprehensively compare the efficacy of these methods, which sample from different compartments of the female genital tract, for the collection of immune factors. Matching sponge and lavage samples were collected from 10 healthy women and were analyzed by tandem mass spectrometry. Data was analyzed by a combination of differential protein expression analysis, hierarchical clustering and pathway analysis. Of the 385 proteins identified, endocervical sponge samples collected nearly twice as many unique proteins as cervicovaginal lavage (111 vs. 61 with 55% of proteins common to both (213. Each method/site identified 73 unique proteins that have roles in host immunity according to their gene ontology. Sponge samples enriched for specific inflammation pathways including acute phase response proteins (p = 3.37×10(-24 and LXR/RXR immune activation pathways (p = 8.82×10(-22 while the role IL-17A in psoriasis pathway (p = 5.98×10(-4 and the complement system pathway (p = 3.91×10(-3 were enriched in lavage samples. Many host defense factors were differentially enriched (p<0.05 between sites including known/potential antimicrobial factors (n = 21, S100 proteins (n = 9, and immune regulatory factors such as serpins (n = 7. Immunoglobulins (n = 6 were collected at comparable levels in abundance in each site although 25% of those identified were unique to sponge samples. This study demonstrates significant differences in types and quantities of immune factors and inflammation pathways collected by each sampling technique. Therefore, clinical studies that measure mucosal immune activation or factors assessing HIV transmission should utilize

  4. Rapid screening method for plutonium in mixed waste samples

    International Nuclear Information System (INIS)

    Somers, W.; Culp, T.; Miller, R.

    1987-01-01

    A waste stream sampling program was undertaken to determine those waste streams which contained hazardous constituents, and would therefore be regulated as a hazardous waste under the Resource Conservation and Recovery Act. The waste streams also had the potential of containing radioactive material, either plutonium, americium, or depleted uranium. Because of the potential for contamination with radioactive material, a method of rapidly screening the liquid samples for radioactive material was required. A counting technique was devised to count a small aliquot of a sample, determine plutonium concentration, and allow the sample to be shipped the same day they were collected. This technique utilized the low energy photons (x-rays) that accompany α decay. This direct, non-destructive x-ray analysis was applied to quantitatively determine Pu-239 concentrations in industrial samples. Samples contained a Pu-239, Am-241 mixture; the ratio and/or concentrations of these two radionuclides was not constant. A computer program was designed and implemented to calculate Pu-239 activity and concentration (g/ml) using the 59.5 keV Am-241 peak to determine Am-241's contribution to the 17 keV region. Am's contribution was subtracted, yielding net counts in the 17 keV region due to Pu. 2 figs., 1 tab

  5. Sampling pig farms at the abattoir in a cross-sectional study - Evaluation of a sampling method.

    Science.gov (United States)

    Birkegård, Anna Camilla; Halasa, Tariq; Toft, Nils

    2017-09-15

    A cross-sectional study design is relatively inexpensive, fast and easy to conduct when compared to other study designs. Careful planning is essential to obtaining a representative sample of the population, and the recommended approach is to use simple random sampling from an exhaustive list of units in the target population. This approach is rarely feasible in practice, and other sampling procedures must often be adopted. For example, when slaughter pigs are the target population, sampling the pigs on the slaughter line may be an alternative to on-site sampling at a list of farms. However, it is difficult to sample a large number of farms from an exact predefined list, due to the logistics and workflow of an abattoir. Therefore, it is necessary to have a systematic sampling procedure and to evaluate the obtained sample with respect to the study objective. We propose a method for 1) planning, 2) conducting, and 3) evaluating the representativeness and reproducibility of a cross-sectional study when simple random sampling is not possible. We used an example of a cross-sectional study with the aim of quantifying the association of antimicrobial resistance and antimicrobial consumption in Danish slaughter pigs. It was not possible to visit farms within the designated timeframe. Therefore, it was decided to use convenience sampling at the abattoir. Our approach was carried out in three steps: 1) planning: using data from meat inspection to plan at which abattoirs and how many farms to sample; 2) conducting: sampling was carried out at five abattoirs; 3) evaluation: representativeness was evaluated by comparing sampled and non-sampled farms, and the reproducibility of the study was assessed through simulated sampling based on meat inspection data from the period where the actual data collection was carried out. In the cross-sectional study samples were taken from 681 Danish pig farms, during five weeks from February to March 2015. The evaluation showed that the sampling

  6. PIXE Analysis of Aerosol and Soil Samples Collected in the Adirondack Mountains

    Science.gov (United States)

    Yoskowitz, Joshua; Ali, Salina; Nadareski, Benjamin; Labrake, Scott; Vineyard, Michael

    2014-09-01

    We have performed an elemental analysis of aerosol and soil samples collected at Piseco Lake in Upstate New York using proton induced X-ray emission spectroscopy (PIXE). This work is part of a systematic study of airborne pollution in the Adirondack Mountains. Of particular interest is the sulfur content that can contribute to acid rain, a well-documented problem in the Adirondacks. We used a nine-stage cascade impactor to collect the aerosol samples near Piseco Lake and distribute the particulate matter onto Kapton foils by particle size. The soil samples were also collected at Piseco Lake and pressed into cylindrical pellets for experimentation. PIXE analysis of the aerosol and soil samples were performed with 2.2-MeV proton beams from the 1.1-MV Pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. There are higher concentrations of sulfur at smaller particle sizes (0.25-1 μm), suggesting that it could be suspended in the air for days and originate from sources very far away. Other elements with significant concentrations peak at larger particle sizes (1-4 μm) and are found in the soil samples, suggesting that these elements could originate in the soil. The PIXE analysis will be described and the resulting data will be presented.

  7. Performance evaluation of a thermal desorption/gas chromatographic/mass spectrometric method for the characterization of waste tank headspace samples

    International Nuclear Information System (INIS)

    Ma, C.Y.; Skeen, J.T.; Dindal, A.B.; Bayne, C.K.; Jenkins, R.A.

    1997-01-01

    A thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS) method was validated for the determination of volatile organic compounds collected on carbonaceous triple sorbent traps and applied to characterize samples of headspace gases collected from underground nuclear waste storage tanks at the U.S. Department of Energy's Hanford site, in Richland, WA. Method validation used vapor-phase standards generated from 25 target analytes, including alkanes, alkyl alcohols, alkyl ketones, alkylated aromatics, and alkyl nitriles. The target analytes represent a group of compounds identified in one of the most problematic tanks. TD/GC/MS was carried out with modified injectors. Performance was characterized based on desorption efficiency, reproducibility, stability, and linearity of the calibration, method detection limits, preanalytical holding time, and quality control limits for surrogate standard recoveries. Desorption efficiencies were all greater than 82%, and the majority of the analytes (23 out of 25) had reproducibility values less than 24% near the method detection levels. The method was applied to the analysis of a total of 305 samples collected from the headspaces of 48 underground waste storge tanks. Quality control procedures were implemented to monitor sampling and TD/GC/MS method. 33 refs., 2 figs., 4 tabs

  8. Removal of arsenic from ground water samples collected from West Bengal, India

    International Nuclear Information System (INIS)

    Ajith, Nicy; Swain, K.K.; Dalvi, Aditi A.; Verma, R.

    2015-01-01

    Arsenic contamination in ground water is one of the major concerns in many parts of the world including Bangladesh and India. Considering the high toxicity of arsenic, World Health Organization (WHO) has set a provisional guideline value of 10 μg L -1 for arsenic in drinking water. Several methods have been adopted for the removal of arsenic from drinking water. Most of the methods fail to remove As(III), the most toxic form of arsenic. An extra oxidative treatment step is essential for effective removal of total arsenic. Manganese dioxide (MnO 2 ) oxidizes As(III) to As(V). Removal of arsenic from water using manganese dioxide has been reported. During this work, removal of arsenic from ground water samples collected from arsenic contaminated area of West Bengal, India were carried out using MnO 2

  9. Qualification for Safeguards Purposes of UF6 Sampling using Alumina – Results of the Evaluation Campaign of ABACC-Cristallini Method

    OpenAIRE

    ESTAEBAN ADOLFO; GAUTIER EDUARDO; MACHADO DA SILVA LUIS; FERNANDEZ MORENO SONIA; RENHA JR GERALDO; DIAS FABIO; PEREIRA DE OLIVEIRA JUNIOR OLIVIO; AMMARAGGI DAVID; MASON PETER; SORIANO MICHAEL; CROATTO PAUL; ZULEGER EVELYN; GIAQUINTO JOSEPH; HEXEL COLE; VERCOUTER THOMAS

    2017-01-01

    The procedure currently used to sample material from process lines in uranium enrichment plants consists of collecting the uranium hexafluoride (UF6) in gaseous phase by desublimation inside a metal sampling cylinder cooled with liquid nitrogen or in certain facilities in a fluorothene P-10 tube type. The ABACC-Cristallini method (A-C method) has been proposed to collect the UF6 (gas) by adsorption in alumina (Al2O3) in the form of uranyl fluoride (UO2F2) (solid). This method uses a fluor...

  10. An improved sampling method of complex network

    Science.gov (United States)

    Gao, Qi; Ding, Xintong; Pan, Feng; Li, Weixing

    2014-12-01

    Sampling subnet is an important topic of complex network research. Sampling methods influence the structure and characteristics of subnet. Random multiple snowball with Cohen (RMSC) process sampling which combines the advantages of random sampling and snowball sampling is proposed in this paper. It has the ability to explore global information and discover the local structure at the same time. The experiments indicate that this novel sampling method could keep the similarity between sampling subnet and original network on degree distribution, connectivity rate and average shortest path. This method is applicable to the situation where the prior knowledge about degree distribution of original network is not sufficient.

  11. Advanced Curation Activities at NASA: Implications for Astrobiological Studies of Future Sample Collections

    Science.gov (United States)

    McCubbin, F. M.; Evans, C. A.; Fries, M. D.; Harrington, A. D.; Regberg, A. B.; Snead, C. J.; Zeigler, R. A.

    2017-01-01

    The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10F JSC is charged with curation of all extraterrestrial material under NASA control, including future NASA missions. The Directive goes on to define Curation as including documentation, preservation, preparation, and distribution of samples for re-search, education, and public outreach. Here we briefly describe NASA's astromaterials collections and our ongoing efforts related to enhancing the utility of our current collections as well as our efforts to prepare for future sample return missions. We collectively refer to these efforts as advanced curation.

  12. Identification of Colored Dyes that are Resistant to Fading on Exposure to Ethylene Oxide; Use with Indicating FTA™ Sample Collection Cards

    Directory of Open Access Journals (Sweden)

    Nina Moran

    2016-01-01

    Full Text Available Regulatory Standards and Forensic Communities are expressing an expectation for HID products to be certified as “DNA-free.” Recently, “DNA-free” status was described for HID-related products using ethylene oxide (EtO; this gas reduces the presence of amplifiable DNA and causes minimal interference to downstream HID-analytical methods. During sample collection, indicating cards, for example, Indicating FTA™ (GE Healthcare Life Sciences, UK, are used to collect and store buccal cell DNA. These cards contain a dye which changes color on application of a colorless sample. Generating “DNA-free” indicating cards using EtO should not impact the dyes' ability to indicate sample location or the efficacy of the card in downstream HID-analytical methods. This study was initiated to identify alternative dyes to those currently used with sample indicating collection cards. The most promising, dyes when applied to cellulose papers exhibited a uniform color distribution and excellent sample indicating properties even when mixed with chemicals associated with FTA™. When dyed cellulose papers were exposed to EtO, ultraviolet radiation, elevated temperature, and humidity, negligible fading or discoloration was observed. The presence of these dyes on cellulose papers did not interfere with direct short tandem repeat (STR profiling. Allelic concordance, first pass success rate, and mean peak heights were comparable to samples applied to Indicating FTA. Biological samples applied to EtO-treated dyed cellulose papers and stored >1 month produced full STR profiles of sufficient quality to allow submission to DNA databases, confirming negligible interference from EtO treatment. These alternative sample indicating dyes resist EtO-mediated fading while fulfilling the Forensic Community's expectation for “DNA-free” with negligible impact on collection card performance.

  13. Method for analysing radium in powder samples and its application to uranium prospecting

    International Nuclear Information System (INIS)

    Gong Xinxi; Hu Minzhi.

    1987-01-01

    The decayed daughter of Rn released from the power sample (soil) in a sealed bottle were collected on a piece of copper and the radium in the sample can be measured by counting α-particles with an Alphameter for uranium prospection, thus it is called the radium method. This method has many advantages, such as high sensitivity (the lowest limit of detection for radium sample per gram is 2.7 x 10 -15 g), high efficiency, low cost and easy to use. On the basis of measuring more than 700 samples taken along 20 sections in 8 deposits, the results show that the radium method is better than γ-measurement and equal to 210 Po method for the capability to descover anomalies. The author also summarizes the anomaly intensities of radium method, 210 Po method and γ-measurement respectively at the surface with deep blind ores, with or without surficial mineralization, and the figures of their profiles and the variation of Ra/ 210 Po ratios. According to the above-mentioned distinguishing features, the uranium mineralization located in deep and/or shallow parts can be distinguishd. The combined application of radium, 210 Po and γ-measurement methods may be regarded as one of the important methods used for anomaly assessment. Based on the experiments of the radium measurements with 771 stream sediments samples in an area of 100 km 2 , it is demonstrated that the radium mehtod can be used in the stages of uranium reconnaissance and prospecting

  14. Comparison of sampling methods for animal manure

    NARCIS (Netherlands)

    Derikx, P.J.L.; Ogink, N.W.M.; Hoeksma, P.

    1997-01-01

    Currently available and recently developed sampling methods for slurry and solid manure were tested for bias and reproducibility in the determination of total phosphorus and nitrogen content of samples. Sampling methods were based on techniques in which samples were taken either during loading from

  15. 77 FR 38323 - Proposed Extension of Existing Information Collection; Respirable Coal Mine Dust Sampling

    Science.gov (United States)

    2012-06-27

    ... Information Collection; Respirable Coal Mine Dust Sampling AGENCY: Mine Safety and Health Administration... Sampling'' to more accurately reflect the type of information that is collected. Chronic exposure to... dust levels since 1970 and, consequently, the prevalence rate of black lung among coal miners, severe...

  16. Comparison between sampling and analytical methods in characterization of pollutants in biogas.

    Science.gov (United States)

    Mariné, Sílvia; Pedrouzo, Marta; Marcé, Rosa Maria; Fonseca, Ignacio; Borrull, Francesc

    2012-10-15

    Different sampling methods involving the collection of biogas by Tedlar bags or adsorption tubes, and different GC-MS injection systems, loop injection or cold trap injection (with bags or by tube desorption), were compared to establish the best method to determine the minority compounds in biogas from sewage treatment plants (STPs). A study of parameters is included, such as the stability of compounds in Tedlar bags or cartridges and the adsorption effect of some less volatile compounds in the thermal desorption system (TD). The optimized methods allowed to determine most compounds at low mgm(-3) levels. Among them, maximum values of D5 (4.84 mg m(-3)), decane (95-118 mg m(-3)) and H(2)S (2223 mg m(-3)) were found in biogas samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Tank 241-U-104 headspace gas and vapor characterization results from samples collected on July 16, 1996

    International Nuclear Information System (INIS)

    Pool, K.H.; Evans, J.C.; Hayes, J.C.; Mitroshkov, A.V.; Edwards, J.A.; Julya, J.L.; Thornton, B.M.; Fruchter, J.S.; Silvers, K.L.

    1997-08-01

    This report presents the results from analyses of samples taken from the headspace of waste storage tank 241-U-104 (Tank U-104) at the Hanford Site in Washington State. Tank headspace samples collected by Westinghouse Hanford Company (WHC) were analyzed by Pacific Northwest National Laboratory (PNNL) to determine headspace concentrations of selected non-radioactive analytes. Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Vapor concentrations from sorbent trap samples are based on measured sample volumes provided by WHC. No analytes were determined to be above the immediate notification limits specified by the sampling and analysis plan. None of the flammable constituents were present at concentrations above the analytical instrument detection limits. Total headspace flammability was estimated to be <0.108% of the lower flammability limit. Average measured concentrations of targeted gases, inorganic vapors, and selected organic vapors are provided in a table. A summary of experimental methods, including sampling methodology, analytical procedures, and quality assurance and control methods are presented in Section 2.0. Detailed descriptions of the analytical results are provided in Section 3.0

  18. Acceptability of self-collected vaginal samples for HPV testing in an ...

    African Journals Online (AJOL)

    Objective: To evaluate the acceptability of self-collected vaginal samples for HPV testing in women living in rural and urban areas of ... Conclusion: Acceptability of self-sampling for HPV testing was similarly excellent in both groups despite their difference in terms ... cancer is the leading cause of death caused by cancer in.

  19. Household vacuum cleaners vs. the high-volume surface sampler for collection of carpet dust samples in epidemiologic studies of children

    Directory of Open Access Journals (Sweden)

    Buffler Patricia A

    2008-02-01

    Full Text Available Abstract Background Levels of pesticides and other compounds in carpet dust can be useful indicators of exposure in epidemiologic studies, particularly for young children who are in frequent contact with carpets. The high-volume surface sampler (HVS3 is often used to collect dust samples in the room in which the child had spent the most time. This method can be expensive and cumbersome, and it has been suggested that an easier method would be to remove dust that had already been collected with the household vacuum cleaner. However, the household vacuum integrates exposures over multiple rooms, some of which are not relevant to the child's exposure, and differences in vacuuming equipment and practices could affect the chemical concentration data. Here, we compare levels of pesticides and other compounds in dust from household vacuums to that collected using the HVS3. Methods Both methods were used in 45 homes in California. HVS3 samples were collected in one room, while the household vacuum had typically been used throughout the home. The samples were analyzed for 64 organic compounds, including pesticides, polycyclic aromatic hydrocarbons, and polychlorinated biphenyls (PCBs, using GC/MS in multiple ion monitoring mode; and for nine metals using conventional microwave-assisted acid digestion combined with ICP/MS. Results The methods agreed in detecting the presence of the compounds 77% to 100% of the time (median 95%. For compounds with less than 100% agreement, neither method was consistently more sensitive than the other. Median concentrations were similar for most analytes, and Spearman correlation coefficients were 0.60 or higher except for allethrin (0.15 and malathion (0.24, which were detected infrequently, and benzo(kfluoranthene (0.55, benzo(apyrene (0.55, PCB 105 (0.54, PCB 118 (0.54, and PCB 138 (0.58. Assuming that the HVS3 method is the "gold standard," the extent to which the household vacuum cleaner method yields relative risk

  20. Headspace vapor characterization of Hanford Waste Tank SX-102: Results from samples collected on July 19, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    McVeety, B.D.; Evans, J.C.; Clauss, T.W.; Pool, K.H.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-SX-102 (Tank SX-102) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed under the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5046. Samples were collected by WHC on July 19, 1995, using the vapor sampling system (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  1. Headspace vapor characterization of Hanford Waste Tank AX-103: Results from samples collected on June 21, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    Ligotke, M.W.; Pool, K.H.; Clauss, T.W.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-AX-103 (Tank AX-103) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5029. Samples were collected by WHC on June 21, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  2. Headspace vapor characterization of Hanford Waste Tank AX-101: Results from samples collected on June 15, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    Pool, K.H.; Clauss, T.W.; Evans, J.C.; McVeety, B.D.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-AX-101 (Tank AX-101) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) under the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5028. Samples were collected by WHC on June 15, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  3. Comparison of sputum collection methods for tuberculosis diagnosis: a systematic review and pairwise and network meta-analysis.

    Science.gov (United States)

    Datta, Sumona; Shah, Lena; Gilman, Robert H; Evans, Carlton A

    2017-08-01

    The performance of laboratory tests to diagnose pulmonary tuberculosis is dependent on the quality of the sputum sample tested. The relative merits of sputum collection methods to improve tuberculosis diagnosis are poorly characterised. We therefore aimed to investigate the effects of sputum collection methods on tuberculosis diagnosis. We did a systematic review and meta-analysis to investigate whether non-invasive sputum collection methods in people aged at least 12 years improve the diagnostic performance of laboratory testing for pulmonary tuberculosis. We searched PubMed, Google Scholar, ProQuest, Web of Science, CINAHL, and Embase up to April 14, 2017, to identify relevant experimental, case-control, or cohort studies. We analysed data by pairwise meta-analyses with a random-effects model and by network meta-analysis. All diagnostic performance data were calculated at the sputum-sample level, except where authors only reported data at the individual patient-level. Heterogeneity was assessed, with potential causes identified by logistic meta-regression. We identified 23 eligible studies published between 1959 and 2017, involving 8967 participants who provided 19 252 sputum samples. Brief, on-demand spot sputum collection was the main reference standard. Pooled sputum collection increased tuberculosis diagnosis by microscopy (odds ratio [OR] 1·6, 95% CI 1·3-1·9, pmeta-analysis confirmed these findings, and revealed that both pooled and instructed spot sputum collections were similarly effective techniques for increasing the diagnostic performance of microscopy. Tuberculosis diagnoses were substantially increased by either pooled collection or by providing instruction on how to produce a sputum sample taken at any time of the day. Both interventions had a similar effect to that reported for the introduction of new, expensive laboratory tests, and therefore warrant further exploration in the drive to end the global tuberculosis epidemic. Wellcome Trust

  4. Analyses of Gas, Steam and Water Samples Collected in and Around Lassen Volcanic National Park, California, 1975-2002

    Science.gov (United States)

    Janik, Cathy J.; Bergfeld, D.

    2010-01-01

    This report contains physical and chemical data from gas, steam, and water samples collected between July 1975 and September 2002 from locations in and around Lassen Volcanic National Park, California. Data are compiled as tables in Excel spreadsheets and are organized by locale. Most data are keyed to 1 of 107 site codes that are shown on local- and regional-scale maps. Brief descriptions of terminology, sampling, and analytical methods are provided.

  5. Efficiently sampling conformations and pathways using the concurrent adaptive sampling (CAS) algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Surl-Hee; Grate, Jay W.; Darve, Eric F.

    2017-08-21

    Molecular dynamics (MD) simulations are useful in obtaining thermodynamic and kinetic properties of bio-molecules but are limited by the timescale barrier, i.e., we may be unable to efficiently obtain properties because we need to run microseconds or longer simulations using femtoseconds time steps. While there are several existing methods to overcome this timescale barrier and efficiently sample thermodynamic and/or kinetic properties, problems remain in regard to being able to sample un- known systems, deal with high-dimensional space of collective variables, and focus the computational effort on slow timescales. Hence, a new sampling method, called the “Concurrent Adaptive Sampling (CAS) algorithm,” has been developed to tackle these three issues and efficiently obtain conformations and pathways. The method is not constrained to use only one or two collective variables, unlike most reaction coordinate-dependent methods. Instead, it can use a large number of collective vari- ables and uses macrostates (a partition of the collective variable space) to enhance the sampling. The exploration is done by running a large number of short simula- tions, and a clustering technique is used to accelerate the sampling. In this paper, we introduce the new methodology and show results from two-dimensional models and bio-molecules, such as penta-alanine and triazine polymer

  6. Analysis of Drugs of Abuse in Anonymously Collected Urine and Soil samples from a Music Festival in Scandinavia

    DEFF Research Database (Denmark)

    Mardal, Marie; Ramin, Pedram; Plósz, Benedek G.

    Aim: Pooled human urine and soil from urinating spots were collected anonymously at a Scandinavian music festival. Samples should be screened for drugs of abuse, particularly novel psychoactive substances (NPS), but also therapeutic drugs and ethanol. Methods: Twenty-one urine samples were...... be detected besides several therapeutic drugs: cocaine (9), MDMA (7), sildenafil (2), ketamine (1), amphetamine (1), and oxycodone (1). Conclusions: NPS were detected neither in urine nor in soil samples. This might be due to low concentrations based on their negligible consumption at the studied festival...

  7. A quantitative method to detect explosives and selected semivolatiles in soil samples by Fourier transform infrared spectroscopy

    International Nuclear Information System (INIS)

    Clapper-Gowdy, M.; Dermirgian, J.; Robitaille, G.

    1995-01-01

    This paper describes a novel Fourier transform infrared (FTIR) spectroscopic method that can be used to rapidly screen soil samples from potentially hazardous waste sites. Samples are heated in a thermal desorption unit and the resultant vapors are collected and analyzed in a long-path gas cell mounted in a FTIR. Laboratory analysis of a soil sample by FTIR takes approximately 10 minutes. This method has been developed to identify and quantify microgram concentrations of explosives in soil samples and is directly applicable to the detection of selected volatile organics, semivolatile organics, and pesticides

  8. System and method for liquid extraction electrospray-assisted sample transfer to solution for chemical analysis

    Science.gov (United States)

    Kertesz, Vilmos; Van Berkel, Gary J.

    2016-07-12

    A system for sampling a surface includes a surface sampling probe comprising a solvent liquid supply conduit and a distal end, and a sample collector for suspending a sample collection liquid adjacent to the distal end of the probe. A first electrode provides a first voltage to solvent liquid at the distal end of the probe. The first voltage produces a field sufficient to generate electrospray plume at the distal end of the probe. A second electrode provides a second voltage and is positioned to produce a plume-directing field sufficient to direct the electrospray droplets and ions to the suspended sample collection liquid. The second voltage is less than the first voltage in absolute value. A voltage supply system supplies the voltages to the first electrode and the second electrode. The first electrode can apply the first voltage directly to the solvent liquid. A method for sampling for a surface is also disclosed.

  9. Detection of Mycoplasma synoviae in clinical samples by VlhA-PCR method

    Directory of Open Access Journals (Sweden)

    H Ansari

    2010-02-01

    Full Text Available As one of the major pathogens of avian species, Mycoplasma Synoviae causes significant economic losses to the poultry industry. The main purpose of this study was to detect Mycoplasma Synoviae in clinical samples using the VlhA-PCR method. For serological screening test, 373 serum samples were collected from 25 breeder farms and rapid serum agglutination test conducted which revealed that 143 samples equivalent to 19 breeder farms were positive. For VlhA-PCR assay, 20 of the previously mentioned breeder farms were selected and sterile swab were collected from the palatine cleft, trachea, air sacs and lungs. Three swabs from 3 birds were placed in a test tube containing 1 ml of PBS and transferred to the laboratory for PCR test. Specific primers for VIhA gene were employed in this study. The PCR product from specific primers showed 350-400 bp for all field isolated on electrophoresis gel in 8 farms. VlhA-PCR with high sensitivity could be employed in definitive diagnosis of Mycoplasma Synoviae infection in the laboratory.

  10. Comparison of soil sampling and analytical methods for asbestos at the Sumas Mountain Asbestos Site-Working towards a toolbox for better assessment.

    Science.gov (United States)

    Wroble, Julie; Frederick, Timothy; Frame, Alicia; Vallero, Daniel

    2017-01-01

    Established soil sampling methods for asbestos are inadequate to support risk assessment and risk-based decision making at Superfund sites due to difficulties in detecting asbestos at low concentrations and difficulty in extrapolating soil concentrations to air concentrations. Environmental Protection Agency (EPA)'s Office of Land and Emergency Management (OLEM) currently recommends the rigorous process of Activity Based Sampling (ABS) to characterize site exposures. The purpose of this study was to compare three soil analytical methods and two soil sampling methods to determine whether one method, or combination of methods, would yield more reliable soil asbestos data than other methods. Samples were collected using both traditional discrete ("grab") samples and incremental sampling methodology (ISM). Analyses were conducted using polarized light microscopy (PLM), transmission electron microscopy (TEM) methods or a combination of these two methods. Data show that the fluidized bed asbestos segregator (FBAS) followed by TEM analysis could detect asbestos at locations that were not detected using other analytical methods; however, this method exhibited high relative standard deviations, indicating the results may be more variable than other soil asbestos methods. The comparison of samples collected using ISM versus discrete techniques for asbestos resulted in no clear conclusions regarding preferred sampling method. However, analytical results for metals clearly showed that measured concentrations in ISM samples were less variable than discrete samples.

  11. Protein Profile study of clinical samples using Laser Induced Fluorescence as the detection method

    DEFF Research Database (Denmark)

    Karemore, Gopal Raghunath; Raja, Sujatha N.; Rai, Lavanya

    2009-01-01

      Protein profiles of tissue homogenates were recorded using HPLC separation and LIF detection method. The samples were collected from volunteers with clinically normal or cervical cancer conditions. It is shown that the protein profile can be classified as belonging to malignant or normal state ...

  12. Evaluation of Sampling Methods for Bacillus Spore ...

    Science.gov (United States)

    Journal Article Following a wide area release of biological materials, mapping the extent of contamination is essential for orderly response and decontamination operations. HVAC filters process large volumes of air and therefore collect highly representative particulate samples in buildings. HVAC filter extraction may have great utility in rapidly estimating the extent of building contamination following a large-scale incident. However, until now, no studies have been conducted comparing the two most appropriate sampling approaches for HVAC filter materials: direct extraction and vacuum-based sampling.

  13. Simultaneous PIXE and PIGE analyses of aerosol samples collected in urban areas

    International Nuclear Information System (INIS)

    Boni, C.; Caruso, E.; Cereda, E.; Marcazzan, G.M.; Redaelli, P.; Bacci, P.

    1988-01-01

    The paper concerns the simultaneous PIXE (Particle Induced X-ray Emission) and PIGE (Proton Induced Gamma-ray Emission) analyses of aerosol samples collected in urban areas. The results show that PIGE can detect Li, F, Na, Al, and Si in fly ashes and F, Na, Al and Si in atmospheric aerosol. The PIXE-PIGE technique has also been applied to 80 samples of atmospheric particular matter collected above Milan during the winter and summer months of 1986/7, and the average values of concentrations and enrichment factors are given for the detected elements. (U.K.)

  14. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study.

    Science.gov (United States)

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D'Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-06-22

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis ® μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis ® μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis ® μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis ® μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations.

  15. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study

    Science.gov (United States)

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D’Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-01-01

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis®μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis®μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis®μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis®μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations. PMID:28640202

  16. Comparative multielement analyses of airborne particulate samples collected in various areas

    International Nuclear Information System (INIS)

    Mamuro, Tetsuo; Matsuda, Yatsuka; Mizohata, Akira

    1973-01-01

    In order to grasp the characteristic features of the air pollution by particulates in various areas in Japan, multielement analyses by instrumental neutron activation analysis and radioisotope energy dispersive X-ray fluorescence analysis were applied to 31 airborne particulate samples collected in 15 different areas, and the analytical results obtained were compared with one another. All the samples were collected by so-called ''10 micron cut'' samplers, the collection efficiency of which is considered to be 50% at 8μ and nearly zero beyond 10μ. Among the areas in question there are clean seaside areas, heavily industrialized areas, small cities along the Inland Sea or the Pacific Ocean around which industrialization is progressing, a small city having only a big iron work, an area famous for its ceramic industry and so on. The atmospheres over them were found to be quite different not only in pollution extent but also in pollution pattern. (auth.)

  17. A method to combine non-probability sample data with probability sample data in estimating spatial means of environmental variables

    NARCIS (Netherlands)

    Brus, D.J.; Gruijter, de J.J.

    2003-01-01

    In estimating spatial means of environmental variables of a region from data collected by convenience or purposive sampling, validity of the results can be ensured by collecting additional data through probability sampling. The precision of the pi estimator that uses the probability sample can be

  18. Sampling Methods for Detection and Monitoring of the Asian Citrus Psyllid (Hemiptera: Psyllidae).

    Science.gov (United States)

    Monzo, C; Arevalo, H A; Jones, M M; Vanaclocha, P; Croxton, S D; Qureshi, J A; Stansly, P A

    2015-06-01

    The Asian citrus psyllid (ACP), Diaphorina citri Kuwayama is a key pest of citrus due to its role as vector of citrus greening disease or "huanglongbing." ACP monitoring is considered an indispensable tool for management of vector and disease. In the present study, datasets collected between 2009 and 2013 from 245 citrus blocks were used to evaluate precision, sensitivity for detection, and efficiency of five sampling methods. The number of samples needed to reach a 0.25 standard error-mean ratio was estimated using Taylor's power law and used to compare precision among sampling methods. Comparison of detection sensitivity and time expenditure (cost) between stem-tap and other sampling methodologies conducted consecutively at the same location were also assessed. Stem-tap sampling was the most efficient sampling method when ACP densities were moderate to high and served as the basis for comparison with all other methods. Protocols that grouped trees near randomly selected locations across the block were more efficient than sampling trees at random across the block. Sweep net sampling was similar to stem-taps in number of captures per sampled unit, but less precise at any ACP density. Yellow sticky traps were 14 times more sensitive than stem-taps but much more time consuming and thus less efficient except at very low population densities. Visual sampling was efficient for detecting and monitoring ACP at low densities. Suction sampling was time consuming and taxing but the most sensitive of all methods for detection of sparse populations. This information can be used to optimize ACP monitoring efforts. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Application of XRF methods for multielemental analysis of lichen samples collected in Havana City. Comparison with ICP-AES, ICP-MS and FAAS

    International Nuclear Information System (INIS)

    Herrero Fernandez, Zahily; Estevez Alvarez, Juan R.; Montero Alvarez, Alfredo; Pupo Gonzalez, Ivan; Ortueta Milan, Marvic; Mesa Perez, Guillermo; Leyva Bombuse, Dennys; Rodriguez Gonzalez, Maydel; Hernandez Torres, Debora; Padilla Alvarez, Roman; Quejido Cabezas, Alberto J.; Rucandio Saez, Maria I.; Fernandez Diaz, Marta

    2011-01-01

    This paper presents the results of the analysis of Ca, Fe, Zn, Br, Rb, Sr and Pb in samples of lichens used as biomonitors of air pollution collecting in Havana City during 2009-2010. Two different X-Ray Fluorescence methods were used. First, a combination of Si (Li) detector with an annular 109Cd as primary excitation source was employed. The second system consisted in a Mo X-ray tube with a secondary target of Molybdenum and a X-PIPS detector. In both configurations, the correction of matrix effects was achieved by using the Compton scattering peak. The quantification was performed using calibration curves obtained from different biological Certified Reference Materials. The determination of elements by Inductively Coupled Plasma-Atomic Emission Spectrometry, Inductively Coupled Plasma-Mass Spectrometry and Flame Atomic Absorption Spectrophotometry was carried out in order to evaluate the reliability of XRF methods. No significant differences were found between the obtained results by the different techniques. The levels of concentration of the analyzed elements in the lichens in 2009 and 2010 respectively were similar. The elemental distribution patters obtained for each metal were associated with different sources of contamination. (Author)

  20. Characteristics of the samples in the FNG fission deposit collection

    Energy Technology Data Exchange (ETDEWEB)

    Meadows, J.W.

    1990-12-01

    Information concerning the samples in the Fast Neutron Generator (FNG) Group's fission deposit collection has been assembled. This includes the physical dimensions, isotopic analyses, half-lives, alpha emission rates specific activities and deposit weights. 10 refs., 9 figs., 5 tabs.

  1. A comparison of results for samples collected with bailers constructed of different materials

    International Nuclear Information System (INIS)

    Thomey, N.; Ogle, R.; Jackson, J.

    1992-01-01

    A bailer is one of the most common sampling devices used to collect ground water samples. Bailers constructed from various materials are available; teflon, polyvinyl chloride (PVC), polyethylene, and stainless steel are all commonly used. It is widely recognized that sample results can be affected by the material from which the bailer is constructed. Teflon and stainless steel are usually recommended based upon their inert properties. The cost of these bailers is significantly higher than other types. For the purposes of petroleum storage tank investigations, sampling devices that would not compromise sample quality but be more economical than teflon or stainless steel would be especially desirable. Water samples were collected using the different types of bailers; teflon, stainless steel, PVC, and polyethylene. Split samples were analyzed for benzene, toluene, ethylbenzene, total xylenes, and Total Petroleum Hydrocarbons. The analytical results were compared to determine if differences were due to normal analytical variances or due to interaction of the sample with the sampling device. No difference was noted in the results which were obtained

  2. Induction of IL-6 and inhibition of IL-8 secretion in the human airway cell line Calu-3 by urban particulate matter collected with a modified method of PM sampling

    International Nuclear Information System (INIS)

    Alfaro-Moreno, Ernesto; Torres, Victor; Miranda, Javier; Martinez, Leticia; Garcia-Cuellar, Claudia; Nawrot, Tim S.; Vanaudenaerde, Bart; Hoet, Peter; Ramirez-Lopez, Pavel; Rosas, Irma; Nemery, Benoit; Osornio-Vargas, Alvaro Roman

    2009-01-01

    Exposure to particulate matter (PM) induces inflammatory cytokines. In the present study, we evaluated the secretion of IL-6 and IL-8 by an airway cell line exposed to PM with a mean aerodynamic size equal to or less than 10 or 2.5 μm (PM 10 and PM 2.5 , respectively) collected in Mexico City, using a modified high-volume sampling method avoiding the use of solvents or introducing membrane components into the samples. PM was collected on cellulose-nitrate (CN) membranes modified for collection on high-volume samplers. Composition of the particles was evaluated by particle-induced X-ray emission (PIXE) and scanning electron microscopy. The particles (10-160 μg/cm 2 ) were tested on Calu-3 cells. Control cultures were exposed to LPS (10 ng/mL to 100 μg/mL) or silica (10-160 μg/cm 2 ). IL-6 and IL-8 secretions were evaluated by ELISA. An average of 10 mg of PM was recovered form each cellulose-nitrate filter. No evidence of contamination from the filter was found. Cells exposed to PM 10 presented an increase in the secretion of IL-6 (up to 400%), while IL-8 decreased (from 40% to levels below the detection limit). A similar but weaker effect was observed with PM 2.5 . In conclusion, our modified sampling method provides a large amount of urban PM free of membrane contamination. The urban particles induce a decrease in IL-8 secretion that contrasts with the LPS and silica effects. These results suggest that the regulation of IL-8 expression is different for urban particles (complex mixture containing combustion-related particles, soil and biologic components) than for biogenic compounds or pure mineral particles.

  3. Induction of IL-6 and inhibition of IL-8 secretion in the human airway cell line Calu-3 by urban particulate matter collected with a modified method of PM sampling

    Energy Technology Data Exchange (ETDEWEB)

    Alfaro-Moreno, Ernesto, E-mail: ealfaro.incan@gmail.com [Lung Toxicology Unit, Pneumology Section, K.U. Leuven (Belgium); Subdireccion de Investigacion Basica, Instituto Nacional de Cancerologia, Avenida San Fernando 22, C.P. 14080, Mexico D.F. (Mexico); Torres, Victor [Departamento Farmacologia, Facultad de Medicina, U.N.A.M. (Mexico); Miranda, Javier [Departamento de Fisica Experimental, Instituto de Fisca, U.N.A.M. (Mexico); Martinez, Leticia [Deparatmento de Aerobiologia, Centro de Ciencias de la Atmosfera - Facultad de Medicina, U.N.A.M. (Mexico); Garcia-Cuellar, Claudia [Subdireccion de Investigacion Basica, Instituto Nacional de Cancerologia, Avenida San Fernando 22, C.P. 14080, Mexico D.F. (Mexico); Nawrot, Tim S.; Vanaudenaerde, Bart; Hoet, Peter [Lung Toxicology Unit, Pneumology Section, K.U. Leuven (Belgium); Ramirez-Lopez, Pavel [Escuela Superior de Ingenieria Quimica e Industrias Extractivas, I.P.N. (Mexico); Rosas, Irma [Deparatmento de Aerobiologia, Centro de Ciencias de la Atmosfera - Facultad de Medicina, U.N.A.M. (Mexico); Nemery, Benoit [Lung Toxicology Unit, Pneumology Section, K.U. Leuven (Belgium); Osornio-Vargas, Alvaro Roman [Subdireccion de Investigacion Basica, Instituto Nacional de Cancerologia, Avenida San Fernando 22, C.P. 14080, Mexico D.F. (Mexico)

    2009-07-15

    Exposure to particulate matter (PM) induces inflammatory cytokines. In the present study, we evaluated the secretion of IL-6 and IL-8 by an airway cell line exposed to PM with a mean aerodynamic size equal to or less than 10 or 2.5 {mu}m (PM{sub 10} and PM{sub 2.5}, respectively) collected in Mexico City, using a modified high-volume sampling method avoiding the use of solvents or introducing membrane components into the samples. PM was collected on cellulose-nitrate (CN) membranes modified for collection on high-volume samplers. Composition of the particles was evaluated by particle-induced X-ray emission (PIXE) and scanning electron microscopy. The particles (10-160 {mu}g/cm{sup 2}) were tested on Calu-3 cells. Control cultures were exposed to LPS (10 ng/mL to 100 {mu}g/mL) or silica (10-160 {mu}g/cm{sup 2}). IL-6 and IL-8 secretions were evaluated by ELISA. An average of 10 mg of PM was recovered form each cellulose-nitrate filter. No evidence of contamination from the filter was found. Cells exposed to PM{sub 10} presented an increase in the secretion of IL-6 (up to 400%), while IL-8 decreased (from 40% to levels below the detection limit). A similar but weaker effect was observed with PM{sub 2.5}. In conclusion, our modified sampling method provides a large amount of urban PM free of membrane contamination. The urban particles induce a decrease in IL-8 secretion that contrasts with the LPS and silica effects. These results suggest that the regulation of IL-8 expression is different for urban particles (complex mixture containing combustion-related particles, soil and biologic components) than for biogenic compounds or pure mineral particles.

  4. The Importance of Meteorite Collections to Sample Return Missions: Past, Present, and Future Considerations

    Science.gov (United States)

    Welzenbach, L. C.; McCoy, T. J.; Glavin, D. P.; Dworkin, J. P.; Abell, P. A.

    2012-01-01

    While much of the scientific community s current attention is drawn to sample return missions, it is the existing meteorite and cosmic dust collections that both provide the paradigms to be tested by these missions and the context for interpreting the results. Recent sample returns from the Stardust and Hayabusa missions provided us with new materials and insights about our Solar System history and processes. As an example, Stardust sampled CAIs among the population of cometary grains, requiring extensive and unexpected radial mixing in the early solar nebula. This finding would not have been possible, however, without extensive studies of meteoritic CAIs that established their high-temperature, inner Solar System formation. Samples returned by Stardust also revealed the first evidence of a cometary amino acid, a discovery that would not have been possible with current in situ flight instrument technology. The Hayabusa mission provided the final evidence linking ordinary chondrites and S asteroids, a hypothesis that developed from centuries of collection and laboratory and ground-based telescopic studies. In addition to these scientific findings, studies of existing meteorite collections have defined and refined the analytical techniques essential to studying returned samples. As an example, the fortuitous fall of the Allende CV3 and Murchison CM2 chondrites within months before the return of Apollo samples allowed testing of new state-of-the-art analytical facilities. The results of those studies not only prepared us to better study lunar materials, but unanticipated discoveries changed many of our concepts about the earliest history and processes of the solar nebula. This synergy between existing collections and future space exploration is certainly not limited to sample return missions. Laboratory studies confirmed the existence of meteorites from Mars and raised the provocative possibility of preservation of ancient microbial life. The laboratory studies in

  5. Study on Big Database Construction and its Application of Sample Data Collected in CHINA'S First National Geographic Conditions Census Based on Remote Sensing Images

    Science.gov (United States)

    Cheng, T.; Zhou, X.; Jia, Y.; Yang, G.; Bai, J.

    2018-04-01

    In the project of China's First National Geographic Conditions Census, millions of sample data have been collected all over the country for interpreting land cover based on remote sensing images, the quantity of data files reaches more than 12,000,000 and has grown in the following project of National Geographic Conditions Monitoring. By now, using database such as Oracle for storing the big data is the most effective method. However, applicable method is more significant for sample data's management and application. This paper studies a database construction method which is based on relational database with distributed file system. The vector data and file data are saved in different physical location. The key issues and solution method are discussed. Based on this, it studies the application method of sample data and analyzes some kinds of using cases, which could lay the foundation for sample data's application. Particularly, sample data locating in Shaanxi province are selected for verifying the method. At the same time, it takes 10 first-level classes which defined in the land cover classification system for example, and analyzes the spatial distribution and density characteristics of all kinds of sample data. The results verify that the method of database construction which is based on relational database with distributed file system is very useful and applicative for sample data's searching, analyzing and promoted application. Furthermore, sample data collected in the project of China's First National Geographic Conditions Census could be useful in the earth observation and land cover's quality assessment.

  6. 7 CFR 29.110 - Method of sampling.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Method of sampling. 29.110 Section 29.110 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Inspectors, Samplers, and Weighers § 29.110 Method of sampling. In sampling tobacco...

  7. Uniform Sampling Table Method and its Applications II--Evaluating the Uniform Sampling by Experiment.

    Science.gov (United States)

    Chen, Yibin; Chen, Jiaxi; Chen, Xuan; Wang, Min; Wang, Wei

    2015-01-01

    A new method of uniform sampling is evaluated in this paper. The items and indexes were adopted to evaluate the rationality of the uniform sampling. The evaluation items included convenience of operation, uniformity of sampling site distribution, and accuracy and precision of measured results. The evaluation indexes included operational complexity, occupation rate of sampling site in a row and column, relative accuracy of pill weight, and relative deviation of pill weight. They were obtained from three kinds of drugs with different shape and size by four kinds of sampling methods. Gray correlation analysis was adopted to make the comprehensive evaluation by comparing it with the standard method. The experimental results showed that the convenience of uniform sampling method was 1 (100%), odds ratio of occupation rate in a row and column was infinity, relative accuracy was 99.50-99.89%, reproducibility RSD was 0.45-0.89%, and weighted incidence degree exceeded the standard method. Hence, the uniform sampling method was easy to operate, and the selected samples were distributed uniformly. The experimental results demonstrated that the uniform sampling method has good accuracy and reproducibility, which can be put into use in drugs analysis.

  8. Projection operator method for collective tunneling transitions

    International Nuclear Information System (INIS)

    Kohmura, Toshitake; Ohta, Hirofumi; Hashimoto, Yukio; Maruyama, Masahiro

    2002-01-01

    Collective tunneling transitions take place in the case that a system has two nearly degenerate ground states with a slight energy splitting, which provides the time scale of the tunneling. The Liouville equation determines the evolution of the density matrix, while the Schroedinger equation determines that of a state. The Liouville equation seems to be more powerful for calculating accurately the energy splitting of two nearly degenerate eigenstates. However, no method to exactly solve the Liouville eigenvalue equation has been established. The usual projection operator method for the Liouville equation is not feasible. We analytically solve the Liouville evolution equation for nuclear collective tunneling from one Hartree minimum to another, proposing a simple and solvable model Hamiltonian for the transition. We derive an analytical expression for the splitting of energy eigenvalues from a spectral function of the Liouville evolution using a half-projected operator method. A full-order analytical expression for the energy splitting is obtained. We define the collective tunneling path of a microscopic Hamiltonian for collective tunneling, projecting the nuclear ground states onto n-particle n-hole state spaces. It is argued that the collective tunneling path sector of a microscopic Hamiltonian can be transformed into the present solvable model Hamiltonian. (author)

  9. Individual and pen-based oral fluid sampling: A welfare-friendly sampling method for group-housed gestating sows.

    Science.gov (United States)

    Pol, Françoise; Dorenlor, Virginie; Eono, Florent; Eudier, Solveig; Eveno, Eric; Liégard-Vanhecke, Dorine; Rose, Nicolas; Fablet, Christelle

    2017-11-01

    The aims of this study were to assess the feasibility of individual and pen-based oral fluid sampling (OFS) in 35 pig herds with group-housed sows, compare these methods to blood sampling, and assess the factors influencing the success of sampling. Individual samples were collected from at least 30 sows per herd. Pen-based OFS was performed using devices placed in at least three pens for 45min. Information related to the farm, the sows, and their living conditions were collected. Factors significantly associated with the duration of sampling and the chewing behaviour of sows were identified by logistic regression. Individual OFS took 2min 42s on average; the type of floor, swab size, and operator were associated with a sampling time >2min. Pen-based OFS was obtained from 112 devices (62.2%). The type of floor, parity, pen-level activity, and type of feeding were associated with chewing behaviour. Pen activity was associated with the latency to interact with the device. The type of floor, gestation stage, parity, group size, and latency to interact with the device were associated with a chewing time >10min. After 15, 30 and 45min of pen-based OFS, 48%, 60% and 65% of the sows were lying down, respectively. The time spent after the beginning of sampling, genetic type, and time elapsed since the last meal were associated with 50% of the sows lying down at one time point. The mean time to blood sample the sows was 1min 16s and 2min 52s if the number of operators required was considered in the sampling time estimation. The genetic type, parity, and type of floor were significantly associated with a sampling time higher than 1min 30s. This study shows that individual OFS is easy to perform in group-housed sows by a single operator, even though straw-bedded animals take longer to sample than animals housed on slatted floors, and suggests some guidelines to optimise pen-based OFS success. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Fixed-point data-collection method of video signal

    International Nuclear Information System (INIS)

    Tang Yu; Yin Zejie; Qian Weiming; Wu Xiaoyi

    1997-01-01

    The author describes a Fixed-point data-collection method of video signal. The method provides an idea of fixed-point data-collection, and has been successfully applied in the research of real-time radiography on dose field, a project supported by National Science Fund

  11. Freeze dried samples of volcanic gases - a new method for the determination of trace elements by NAA

    International Nuclear Information System (INIS)

    Bichler, M.; Sortino, F.

    1997-01-01

    A new routine technique for the determination of trace elements in volcanic gases by NAA is presented. For time and money saving reasons this method is applicable to samples, collected by the conventional method. This technique uses evacuated glass bottles, partly filled with NaOH solution to absorb acidic gas components and CO 2 , which is the main constituent of the incondensable gas fraction at ambient conditions. The application of NAA to samples collected by this method shows two main sources of difficulties: drying of NaOH without loosing volatile elements of interest (in particular Hg and Se) and the high activities of 24 Na after neutron irradiation. The first can be avoided by liquid irradiation, thereby limiting the irradiation time, the second excludes the determination of short and medium lived nuclides because of the high γ-background due to 24 Na. A new freeze drying technique enables the application of long irradiation times and therefore the use of long-lived activation products for analysis. The samples of volcanic gases were collected at the fumarole fields of La Fossa volcano on the island Vulcano. Southern Italy. This technique allows very sensitive determinations of trace elements in volcanic gases and adds highly valuable information to the understanding and modeling of volcanic gas sources. (orig.)

  12. Headspace vapor characterization of Hanford Waste Tank 241-T-110: Results from samples collected on August 31, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    McVeety, B.D.; Thomas, B.L.; Evans, J.C.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-T-110 (Tank T-110) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5056. Samples were collected by WHC on August 31, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  13. Headspace vapor characterization of Hanford Waste Tank 241-TX-111: Results from samples collected on October 12, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    Pool, K.H.; Clauss, T.W.; Evans, J.C.

    1996-06-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-TX-111 (Tank TX-111) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5069. Samples were collected by WHC on October 12, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  14. Headspace vapor characterization of Hanford Waste Tank 241-SX-109: Results from samples collected on August 1, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    Pool, K.H.; Clauss, T.W.; Evans, J.C.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-SX-109 (Tank SX-109) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5048. Samples were collected by WHC on August 1, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  15. Headspace vapor characterization of Hanford Waste Tank 241-SX-104: Results from samples collected on July 25, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    Thomas, B.L.; Clauss, T.W.; Evans, J.C.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-SX-104 (Tank SX-104) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5049. Samples were collected by WHC on July 25, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  16. Headspace vapor characterization of Hanford Waste Tank 241-S-112: Results from samples collected on July 11, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    Clauss, T.W.; Pool, K.H.; Evans, J.C.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage Tank 241-S-112 (Tank S-112) at the Hanford. Pacific Northwest National Laboratory (PNNL) is contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5044. Samples were collected by WHC on July 11, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  17. Headspace vapor characterization of Hanford Waste Tank 241-SX-105: Results from samples collected on July 26, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    Pool, K.H.; Clauss, T.W.; Evans, J.C.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-SX-105 (Tank SX-105) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5047. Samples were collected by WHC on July 26, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  18. Analysis method of high-order collective-flow correlations based on the concept of correlative degree

    International Nuclear Information System (INIS)

    Zhang Weigang

    2000-01-01

    Based on the concept of correlative degree, a new method of high-order collective-flow measurement is constructed, with which azimuthal correlations, correlations of final state transverse momentum magnitude and transverse correlations can be inspected respectively. Using the new method the contributions of the azimuthal correlations of particles distribution and the correlations of transverse momentum magnitude of final state particles to high-order collective-flow correlations are analyzed respectively with 4π experimental events for 1.2 A GeV Ar + BaI 2 collisions at the Bevalac stream chamber. Comparing with the correlations of transverse momentum magnitude, the azimuthal correlations of final state particles distribution dominate high-order collective-flow correlations in experimental samples. The contributions of correlations of transverse momentum magnitude of final state particles not only enhance the strength of the high-order correlations of particle group, but also provide important information for the measurement of the collectivity of collective flow within the more constraint district

  19. 19 CFR 151.83 - Method of sampling.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Method of sampling. 151.83 Section 151.83 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Cotton § 151.83 Method of sampling. For...

  20. Vapor space characterization of waste tank 241-C-101: Results from samples collected on 9/1/94

    International Nuclear Information System (INIS)

    Lucke, R.B.; Clauss, T.W.; Ligotke, M.W.

    1995-11-01

    This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-C-101 (referred to as Tank C-101) and the ambient air collected - 30 ft upwind near the tank and through the VSS near the tank. Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The sample job was designated S4056, and samples were collected by WHC on September 1, 1994, using the vapor sampling system (VSS). The samples were inspected upon delivery to the 326/23B laboratory and logged into PNL record book 55408 before implementation of PNL Technical Procedure PNL-TVP-07. Custody of the sorbent traps was transferred to PNL personnel performing the inorganic analysis and stored at refrigerated (≤ 10 degrees C) temperature until the time of analysis. The canisters were stored in the 326/23B laboratory at ambient (25 degrees C) temperature until the time of the analysis. Access to the 326/23B laboratory is limited to PNL personnel working on the waste-tank safety program. Analyses described in this report were performed at PNL in the 300 area of the Hanford Reservation. Analytical methods that were used are described in the text. In summary, sorbent traps for inorganic analyses containing sample materials were either weighed (for water analysis) or desorbed with the appropriate aqueous solutions (for NH 3 , NO 2 , and NO analyses). The aqueous extracts were analyzed either by selective electrode or by ion chromatography (IC). Organic analyses were performed using cryogenic preconcentration followed by gas chromatography/mass spectrometry (GC/MS)

  1. Effects of sampling methods on the quantity and quality of dissolved organic matter in sediment pore waters as revealed by absorption and fluorescence spectroscopy.

    Science.gov (United States)

    Chen, Meilian; Lee, Jong-Hyeon; Hur, Jin

    2015-10-01

    Despite literature evidence suggesting the importance of sampling methods on the properties of sediment pore waters, their effects on the dissolved organic matter (PW-DOM) have been unexplored to date. Here, we compared the effects of two commonly used sampling methods (i.e., centrifuge and Rhizon sampler) on the characteristics of PW-DOM for the first time. The bulk dissolved organic carbon (DOC), ultraviolet-visible (UV-Vis) absorption, and excitation-emission matrixes coupled with parallel factor analysis (EEM-PARAFAC) of the PW-DOM samples were compared for the two sampling methods with the sediments from minimal to severely contaminated sites. The centrifuged samples were found to have higher average values of DOC, UV absorption, and protein-like EEM-PARAFAC components. The samples collected with the Rhizon sampler, however, exhibited generally more humified characteristics than the centrifuged ones, implying a preferential collection of PW-DOM with respect to the sampling methods. Furthermore, the differences between the two sampling methods seem more pronounced in relatively more polluted sites. Our observations were possibly explained by either the filtration effect resulting from the smaller pore size of the Rhizon sampler or the desorption of DOM molecules loosely bound to minerals during centrifugation, or both. Our study suggests that consistent use of one sampling method is crucial for PW-DOM studies and also that caution should be taken in the comparison of data collected with different sampling methods.

  2. ALARA ASSESSMENT OF SETTLER SLUDGE SAMPLING METHODS

    International Nuclear Information System (INIS)

    Nelsen, L.A.

    2009-01-01

    The purpose of this assessment is to compare underwater and above water settler sludge sampling methods to determine if the added cost for underwater sampling for the sole purpose of worker dose reductions is justified. Initial planning for sludge sampling included container, settler and knock-out-pot (KOP) sampling. Due to the significantly higher dose consequence of KOP sludge, a decision was made to sample KOP underwater to achieve worker dose reductions. Additionally, initial plans were to utilize the underwater sampling apparatus for settler sludge. Since there are no longer plans to sample KOP sludge, the decision for underwater sampling for settler sludge needs to be revisited. The present sampling plan calls for spending an estimated $2,500,000 to design and construct a new underwater sampling system (per A21 C-PL-001 RevOE). This evaluation will compare and contrast the present method of above water sampling to the underwater method that is planned by the Sludge Treatment Project (STP) and determine if settler samples can be taken using the existing sampling cart (with potentially minor modifications) while maintaining doses to workers As Low As Reasonably Achievable (ALARA) and eliminate the need for costly redesigns, testing and personnel retraining

  3. ALARA ASSESSMENT OF SETTLER SLUDGE SAMPLING METHODS

    Energy Technology Data Exchange (ETDEWEB)

    NELSEN LA

    2009-01-30

    The purpose of this assessment is to compare underwater and above water settler sludge sampling methods to determine if the added cost for underwater sampling for the sole purpose of worker dose reductions is justified. Initial planning for sludge sampling included container, settler and knock-out-pot (KOP) sampling. Due to the significantly higher dose consequence of KOP sludge, a decision was made to sample KOP underwater to achieve worker dose reductions. Additionally, initial plans were to utilize the underwater sampling apparatus for settler sludge. Since there are no longer plans to sample KOP sludge, the decision for underwater sampling for settler sludge needs to be revisited. The present sampling plan calls for spending an estimated $2,500,000 to design and construct a new underwater sampling system (per A21 C-PL-001 RevOE). This evaluation will compare and contrast the present method of above water sampling to the underwater method that is planned by the Sludge Treatment Project (STP) and determine if settler samples can be taken using the existing sampling cart (with potentially minor modifications) while maintaining doses to workers As Low As Reasonably Achievable (ALARA) and eliminate the need for costly redesigns, testing and personnel retraining.

  4. A simple web-based tool to compare freshwater fish data collected using AFS standard methods

    Science.gov (United States)

    Bonar, Scott A.; Mercado-Silva, Norman; Rahr, Matt; Torrey, Yuta T.; Cate, Averill

    2016-01-01

    The American Fisheries Society (AFS) recently published Standard Methods for Sampling North American Freshwater Fishes. Enlisting the expertise of 284 scientists from 107 organizations throughout Canada, Mexico, and the United States, this text was developed to facilitate comparisons of fish data across regions or time. Here we describe a user-friendly web tool that automates among-sample comparisons in individual fish condition, population length-frequency distributions, and catch per unit effort (CPUE) data collected using AFS standard methods. Currently, the web tool (1) provides instantaneous summaries of almost 4,000 data sets of condition, length frequency, and CPUE of common freshwater fishes collected using standard gears in 43 states and provinces; (2) is easily appended with new standardized field data to update subsequent queries and summaries; (3) compares fish data from a particular water body with continent, ecoregion, and state data summaries; and (4) provides additional information about AFS standard fish sampling including benefits, ongoing validation studies, and opportunities to comment on specific methods. The web tool—programmed in a PHP-based Drupal framework—was supported by several AFS Sections, agencies, and universities and is freely available from the AFS website and fisheriesstandardsampling.org. With widespread use, the online tool could become an important resource for fisheries biologists.

  5. Conducting Internet Research With the Transgender Population: Reaching Broad Samples and Collecting Valid Data.

    Science.gov (United States)

    Miner, Michael H; Bockting, Walter O; Romine, Rebecca Swinburne; Raman, Sivakumaran

    2012-05-01

    Health research on transgender people has been hampered by the challenges inherent in studying a hard-to-reach, relatively small, and geographically dispersed population. The Internet has the potential to facilitate access to transgender samples large enough to permit examination of the diversity and syndemic health disparities found among this population. In this article, we describe the experiences of a team of investigators using the Internet to study HIV risk behaviors of transgender people in the United States. We developed an online instrument, recruited participants exclusively via websites frequented by members of the target population, and collected data using online quantitative survey and qualitative synchronous and asynchronous interview methods. Our experiences indicate that the Internet environment presents the investigator with some unique challenges and that commonly expressed criticisms about Internet research (e.g., lack of generalizable samples, invalid study participants, and multiple participation by the same subject) can be overcome with careful method design, usability testing, and pilot testing. The importance of both usability and pilot testing are described with respect to participant engagement and retention and the quality of data obtained online.

  6. Curating NASA's future extraterrestrial sample collections: How do we achieve maximum proficiency?

    Science.gov (United States)

    McCubbin, Francis; Evans, Cynthia; Allton, Judith; Fries, Marc; Righter, Kevin; Zolensky, Michael; Zeigler, Ryan

    2016-07-01

    Introduction: The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10E "Curation of Extraterrestrial Materials", JSC is charged with "The curation of all extraterrestrial material under NASA control, including future NASA missions." The Directive goes on to define Curation as including "…documentation, preservation, preparation, and distribution of samples for research, education, and public outreach." Here we describe some of the ongoing efforts to ensure that the future activities of the NASA Curation Office are working to-wards a state of maximum proficiency. Founding Principle: Curatorial activities began at JSC (Manned Spacecraft Center before 1973) as soon as design and construction planning for the Lunar Receiving Laboratory (LRL) began in 1964 [1], not with the return of the Apollo samples in 1969, nor with the completion of the LRL in 1967. This practice has since proven that curation begins as soon as a sample return mission is conceived, and this founding principle continues to return dividends today [e.g., 2]. The Next Decade: Part of the curation process is planning for the future, and we refer to these planning efforts as "advanced curation" [3]. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of collections as envisioned by NASA exploration goals. We are (and have been) planning for future curation, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, curation of organically- and biologically-sensitive samples, and the use of minimally invasive analytical techniques (e.g., micro-CT, [4]) to characterize samples. These efforts will be useful for Mars Sample Return

  7. Waste classification sampling plan

    International Nuclear Information System (INIS)

    Landsman, S.D.

    1998-01-01

    The purpose of this sampling is to explain the method used to collect and analyze data necessary to verify and/or determine the radionuclide content of the B-Cell decontamination and decommissioning waste stream so that the correct waste classification for the waste stream can be made, and to collect samples for studies of decontamination methods that could be used to remove fixed contamination present on the waste. The scope of this plan is to establish the technical basis for collecting samples and compiling quantitative data on the radioactive constituents present in waste generated during deactivation activities in B-Cell. Sampling and radioisotopic analysis will be performed on the fixed layers of contamination present on structural material and internal surfaces of process piping and tanks. In addition, dose rate measurements on existing waste material will be performed to determine the fraction of dose rate attributable to both removable and fixed contamination. Samples will also be collected to support studies of decontamination methods that are effective in removing the fixed contamination present on the waste. Sampling performed under this plan will meet criteria established in BNF-2596, Data Quality Objectives for the B-Cell Waste Stream Classification Sampling, J. M. Barnett, May 1998

  8. Planning for the Collection and Analysis of Samples of Martian Granular Materials Potentially to be Returned by Mars Sample Return

    Science.gov (United States)

    Carrier, B. L.; Beaty, D. W.

    2017-12-01

    NASA's Mars 2020 rover is scheduled to land on Mars in 2021 and will be equipped with a sampling system capable of collecting rock cores, as well as a specialized drill bit for collecting unconsolidated granular material. A key mission objective is to collect a set of samples that have enough scientific merit to justify returning to Earth. In the case of granular materials, we would like to catalyze community discussion on what we would do with these samples if they arrived in our laboratories, as input to decision-making related to sampling the regolith. Numerous scientific objectives have been identified which could be achieved or significantly advanced via the analysis of martian rocks, "regolith," and gas samples. The term "regolith" has more than one definition, including one that is general and one that is much more specific. For the purpose of this analysis we use the term "granular materials" to encompass the most general meaning and restrict "regolith" to a subset of that. Our working taxonomy includes the following: 1) globally sourced airfall dust (dust); 2) saltation-sized particles (sand); 3) locally sourced decomposed rock (regolith); 4) crater ejecta (ejecta); and, 5) other. Analysis of martian granular materials could serve to advance our understanding areas including habitability and astrobiology, surface-atmosphere interactions, chemistry, mineralogy, geology and environmental processes. Results of these analyses would also provide input into planning for future human exploration of Mars, elucidating possible health and mechanical hazards caused by the martian surface material, as well as providing valuable information regarding available resources for ISRU and civil engineering purposes. Results would also be relevant to matters of planetary protection and ground-truthing orbital observations. We will present a preliminary analysis of the following, in order to generate community discussion and feedback on all issues relating to: What are the

  9. Free water {sup 3}H concentration in diet samples collected during 1969-88 in Akita, Japan

    Energy Technology Data Exchange (ETDEWEB)

    Hisamatsu, S. [Institute for Environmental Sciences, Rokkasho, Aomori (Japan); Inoue, Y.; Miyamoto, K. [National Inst. of Radiological Sciences, Chiba (Japan); Takizawa, Y. [National Institute for Minamata Disease, Minamata, Kumamoto (Japan)

    2000-05-01

    Fallout {sup 3}H concentrations in diet samples collected during 1969-88 in Akita Prefecture are reported in this paper. Since {sup 3}H is a potential nuclear fuel for fusion reactors in future, its environmental behavior is important for dose assessment of released {sup 3}H from the plants. Tritium in foods is classified into two types; free water {sup 3}H (FWT) and organically-bound {sup 3}H (OBT). The FWT is practically separated by means of freeze-drying, while the OBT is measured with water sample collected by combustion of dried sample. The OBT concentrations in foods and human tissue samples were reported for {sup 3}H originating from nuclear weapon fallout. We already published {sup 3}H concentrations in diet samples collected in Akita City during 1985-88. Although results for the samples collected in U.S.A. and European countries in the 1970s showed higher specific activity of OBT than FWT, our recent results in Japan indicate almost the same specific activity between them. Since the measurements for the samples in 1960s and 1970s are important to understand the long-term movement of {sup 3}H in the environment, we have searched old diet samples. Recently, diet samples collected in Akita Prefecture during 1969-80 were found and obtained for {sup 3}H analysis. The samples were originally gathered for nutrition survey programs and consisted of duplicate diet samples for 1 day from 10-30 persons. Food samples excluding boiled rice which is the staple food was homogenized by electric mixers after adding tap water. Then, the food and the boiled rice samples were stored in a refrigerator at -20degC. Free water in the samples was collected with lyophilization, then {sup 3}H in the water sample was measured after purification with low-level liquid scintillation counters. The free water {sup 3}H concentrations were measured for 57 diet samples (dish excluding boiled rice) and 17 boiled rice samples. The free water {sup 3}H concentrations in diet and rice samples

  10. Sampling methods in archaeomagnetic dating: A comparison using case studies from Wörterberg, Eisenerz and Gams Valley (Austria)

    Science.gov (United States)

    Trapanese, A.; Batt, C. M.; Schnepp, E.

    The aim of this research was to review the relative merits of different methods of taking samples for archaeomagnetic dating. To allow different methods to be investigated, two archaeological structures and one modern fireplace were sampled in Austria. On each structure a variety of sampling methods were used: the tube and disc techniques of Clark et al. (Clark, A.J., Tarling, D.H., Noel, M., 1988. Developments in archaeomagnetic dating in Great Britain. Journal of Archaeological Science 15, 645-667), the drill core technique, the mould plastered hand block method of Thellier, and a modification of it. All samples were oriented with a magnetic compass and sun compass, where weather conditions allowed. Approximately 12 discs, tubes, drill cores or plaster hand blocks were collected from each structure, with one mould plaster hand block being collected and cut into specimens. The natural remanent magnetisation (NRM) of the samples was measured and stepwise alternating field (AF) or thermal demagnetisation was applied. Samples were measured either in the UK or in Austria, which allowed the comparison of results between magnetometers with different sensitivity. The tubes and plastered hand block specimens showed good agreement in directional results, and the samples obtained showed good stability. The discs proved to be unreliable as both NRM and the characteristic remanent magnetisation (ChRM) distribution were very scattered. The failure of some methods may be related to the suitability of the material sampled, for example if it was disturbed before sampling, had been insufficiently heated or did not contain appropriate magnetic minerals to retain a remanent magnetisation. Caution is also recommended for laboratory procedures as the cutting of poorly consolidated specimens may disturb the material and therefore the remanent magnetisation. Criteria and guidelines were established to aid researchers in selecting the most appropriate method for a particular

  11. Randomized Comparison of Two Vaginal Self-Sampling Methods for Human Papillomavirus Detection: Dry Swab versus FTA Cartridge.

    Science.gov (United States)

    Catarino, Rosa; Vassilakos, Pierre; Bilancioni, Aline; Vanden Eynde, Mathieu; Meyer-Hamme, Ulrike; Menoud, Pierre-Alain; Guerry, Frédéric; Petignat, Patrick

    2015-01-01

    Human papillomavirus (HPV) self-sampling (self-HPV) is valuable in cervical cancer screening. HPV testing is usually performed on physician-collected cervical smears stored in liquid-based medium. Dry filters and swabs are an alternative. We evaluated the adequacy of self-HPV using two dry storage and transport devices, the FTA cartridge and swab. A total of 130 women performed two consecutive self-HPV samples. Randomization determined which of the two tests was performed first: self-HPV using dry swabs (s-DRY) or vaginal specimen collection using a cytobrush applied to an FTA cartridge (s-FTA). After self-HPV, a physician collected a cervical sample using liquid-based medium (Dr-WET). HPV types were identified by real-time PCR. Agreement between collection methods was measured using the kappa statistic. HPV prevalence for high-risk types was 62.3% (95%CI: 53.7-70.2) detected by s-DRY, 56.2% (95%CI: 47.6-64.4) by Dr-WET, and 54.6% (95%CI: 46.1-62.9) by s-FTA. There was overall agreement of 70.8% between s-FTA and s-DRY samples (kappa = 0.34), and of 82.3% between self-HPV and Dr-WET samples (kappa = 0.56). Detection sensitivities for low-grade squamous intraepithelial lesion or worse (LSIL+) were: 64.0% (95%CI: 44.5-79.8) for s-FTA, 84.6% (95%CI: 66.5-93.9) for s-DRY, and 76.9% (95%CI: 58.0-89.0) for Dr-WET. The preferred self-collection method among patients was s-DRY (40.8% vs. 15.4%). Regarding costs, FTA card was five times more expensive than the swab (~5 US dollars (USD)/per card vs. ~1 USD/per swab). Self-HPV using dry swabs is sensitive for detecting LSIL+ and less expensive than s-FTA. International Standard Randomized Controlled Trial Number (ISRCTN): 43310942.

  12. Development of sampling method and chromatographic analysis of volatile organic compounds emitted from human skin.

    Science.gov (United States)

    Grabowska-Polanowska, Beata; Miarka, Przemysław; Skowron, Monika; Sułowicz, Joanna; Wojtyna, Katarzyna; Moskal, Karolina; Śliwka, Ireneusz

    2017-10-01

    The studies on volatile organic compounds emitted from skin are an interest for chemists, biologists and physicians due to their role in development of different scientific areas, including medical diagnostics, forensic medicine and the perfume design. This paper presents a proposal of two sampling methods applied to skin odor collection: the first one uses a bag of cellulose film, the second one, using cellulose sachets filled with active carbon. Volatile organic compounds were adsorbed on carbon sorbent, removed via thermal desorption and analyzed using gas chromatograph with mass spectrometer. The first sampling method allowed identification of more compounds (52) comparing to the second one (30). Quantitative analyses for acetone, butanal, pentanal and hexanal were done. The skin odor sampling method using a bag of cellulose film, allowed the identification of many more compounds when compared with the method using a sachet filled with active carbon.

  13. Survey of elemental concentrations in lichen samples collected from Sao Paulo State

    International Nuclear Information System (INIS)

    Saiki, M.; Horimoto, L.K.; Vasconcellos, M.B.A.; Coccaro, D.M.B.; Marcelli, M.P.

    2001-01-01

    Samples of the lichen Canoparmelia texana collected in seven different sites of Sao Paulo State and one site of the Parana State were analysed by neutron activation analysis in order to obtain information on the air quality in these regions and also to select a region of interest for the evaluation of baseline level of elements in lichen species. Concentrations of the elements Al, As, Br, Ca, Cd, Cl, Co, Cs, Fe, Hf, K, Mg, Mn, Na, Rb, Sb, Sc, Se, Ti, Th, U, V, Zn and lanthanides were determined and a preliminary comparisons was made between the results obtained for samples collected in different sites. (author)

  14. A Throughfall Collection Method Using Mixed Bed Ion Exchange Resin Columns

    Directory of Open Access Journals (Sweden)

    Mark E. Fenn

    2002-01-01

    Full Text Available Measurement of ionic deposition in throughfall is a widely used method for measuring deposition inputs to the forest floor. Many studies have been published, providing a large database of throughfall deposition inputs to forests. However, throughfall collection and analysis is labor intensive and expensive because of the large number of replicate collectors needed and because sample collection and chemical analyses are required on a stochastic precipitation event-based schedule. Therefore we developed and tested a throughfall collector system using a mixed bed ion exchange resin column. We anticipate that this method will typically require only one to three samplings per year. With this method, bulk deposition and bulk throughfall are collected by a funnel or snow tube and ions are retained as the solution percolates through the resin column. Ions retained by the resin are then extracted in the same column with 2N KCl and analyzed for nitrate and ammonium. Deposition values in throughfall from conventional throughfall solution collectors and colocated ion exchange samplers were not significantly different during consecutive 3- and 4-month exposure periods at a high (Camp Paivika; >35 kg N ha-1 year-1 and a low deposition (Barton Flats; 5–9 kg N ha-1 year-1 site in the San Bernardino Mountains in southern California. N deposition in throughfall under mature pine trees at Camp Paivika after 7 months of exposure was extremely high (87 and 92 kg ha-1 based on the two collector types compared to Barton Flats (11 and 13 kg ha-1. A large proportion of the N deposited in throughfall at Camp Paivika occurred as fog drip, demonstrating the importance of fog deposition as an input source of N at this site. By comparison, bulk deposition rates in open areas were 5.1 and 5.4 kg ha-1 at Camp Paivika based on the two collector types, and 1.9 and 3.0 kg ha-1 at Barton Flats.

  15. Standard methods for sampling and sample preparation for gamma spectroscopy

    International Nuclear Information System (INIS)

    Taskaeva, M.; Taskaev, E.; Nikolov, P.

    1993-01-01

    The strategy for sampling and sample preparation is outlined: necessary number of samples; analysis and treatment of the results received; quantity of the analysed material according to the radionuclide concentrations and analytical methods; the minimal quantity and kind of the data needed for making final conclusions and decisions on the base of the results received. This strategy was tested in gamma spectroscopic analysis of radionuclide contamination of the region of Eleshnitsa Uranium Mines. The water samples was taken and stored according to the ASTM D 3370-82. The general sampling procedures were in conformity with the recommendations of ISO 5667. The radionuclides was concentrated by coprecipitation with iron hydroxide and ion exchange. The sampling of soil samples complied with the rules of ASTM C 998, and their sample preparation - with ASTM C 999. After preparation the samples were sealed hermetically and measured. (author)

  16. Environmental DNA method for estimating salamander distribution in headwater streams, and a comparison of water sampling methods.

    Science.gov (United States)

    Katano, Izumi; Harada, Ken; Doi, Hideyuki; Souma, Rio; Minamoto, Toshifumi

    2017-01-01

    Environmental DNA (eDNA) has recently been used for detecting the distribution of macroorganisms in various aquatic habitats. In this study, we applied an eDNA method to estimate the distribution of the Japanese clawed salamander, Onychodactylus japonicus, in headwater streams. Additionally, we compared the detection of eDNA and hand-capturing methods used for determining the distribution of O. japonicus. For eDNA detection, we designed a qPCR primer/probe set for O. japonicus using the 12S rRNA region. We detected the eDNA of O. japonicus at all sites (with the exception of one), where we also observed them by hand-capturing. Additionally, we detected eDNA at two sites where we were unable to observe individuals using the hand-capturing method. Moreover, we found that eDNA concentrations and detection rates of the two water sampling areas (stream surface and under stones) were not significantly different, although the eDNA concentration in the water under stones was more varied than that on the surface. We, therefore, conclude that eDNA methods could be used to determine the distribution of macroorganisms inhabiting headwater systems by using samples collected from the surface of the water.

  17. Sampling bee communities using pan traps: alternative methods increase sample size

    Science.gov (United States)

    Monitoring of the status of bee populations and inventories of bee faunas require systematic sampling. Efficiency and ease of implementation has encouraged the use of pan traps to sample bees. Efforts to find an optimal standardized sampling method for pan traps have focused on pan trap color. Th...

  18. Perilymph sampling from the cochlear apex: a reliable method to obtain higher purity perilymph samples from scala tympani.

    Science.gov (United States)

    Salt, Alec N; Hale, Shane A; Plonkte, Stefan K R

    2006-05-15

    Measurements of drug levels in the fluids of the inner ear are required to establish kinetic parameters and to determine the influence of specific local delivery protocols. For most substances, this requires cochlear fluids samples to be obtained for analysis. When auditory function is of primary interest, the drug level in the perilymph of scala tympani (ST) is most relevant, since drug in this scala has ready access to the auditory sensory cells. In many prior studies, ST perilymph samples have been obtained from the basal turn, either by aspiration through the round window membrane (RWM) or through an opening in the bony wall. A number of studies have demonstrated that such samples are likely to be contaminated with cerebrospinal fluid (CSF). CSF enters the basal turn of ST through the cochlear aqueduct when the bony capsule is perforated or when fluid is aspirated. The degree of sample contamination has, however, not been widely appreciated. Recent studies have shown that perilymph samples taken through the round window membrane are highly contaminated with CSF, with samples greater than 2microL in volume containing more CSF than perilymph. In spite of this knowledge, many groups continue to sample from the base of the cochlea, as it is a well-established method. We have developed an alternative, technically simple method to increase the proportion of ST perilymph in a fluid sample. The sample is taken from the apex of the cochlea, a site that is distant from the cochlear aqueduct. A previous problem with sampling through a perforation in the bone was that the native perilymph rapidly leaked out driven by CSF pressure and was lost to the middle ear space. We therefore developed a procedure to collect all the fluid that emerged from the perforated apex after perforation. We evaluated the method using a marker ion trimethylphenylammonium (TMPA). TMPA was applied to the perilymph of guinea pigs either by RW irrigation or by microinjection into the apical turn. The

  19. New adaptive sampling method in particle image velocimetry

    International Nuclear Information System (INIS)

    Yu, Kaikai; Xu, Jinglei; Tang, Lan; Mo, Jianwei

    2015-01-01

    This study proposes a new adaptive method to enable the number of interrogation windows and their positions in a particle image velocimetry (PIV) image interrogation algorithm to become self-adapted according to the seeding density. The proposed method can relax the constraint of uniform sampling rate and uniform window size commonly adopted in the traditional PIV algorithm. In addition, the positions of the sampling points are redistributed on the basis of the spring force generated by the sampling points. The advantages include control of the number of interrogation windows according to the local seeding density and smoother distribution of sampling points. The reliability of the adaptive sampling method is illustrated by processing synthetic and experimental images. The synthetic example attests to the advantages of the sampling method. Compared with that of the uniform interrogation technique in the experimental application, the spatial resolution is locally enhanced when using the proposed sampling method. (technical design note)

  20. A general method to determine sampling windows for nonlinear mixed effects models with an application to population pharmacokinetic studies.

    Science.gov (United States)

    Foo, Lee Kien; McGree, James; Duffull, Stephen

    2012-01-01

    Optimal design methods have been proposed to determine the best sampling times when sparse blood sampling is required in clinical pharmacokinetic studies. However, the optimal blood sampling time points may not be feasible in clinical practice. Sampling windows, a time interval for blood sample collection, have been proposed to provide flexibility in blood sampling times while preserving efficient parameter estimation. Because of the complexity of the population pharmacokinetic models, which are generally nonlinear mixed effects models, there is no analytical solution available to determine sampling windows. We propose a method for determination of sampling windows based on MCMC sampling techniques. The proposed method attains a stationary distribution rapidly and provides time-sensitive windows around the optimal design points. The proposed method is applicable to determine sampling windows for any nonlinear mixed effects model although our work focuses on an application to population pharmacokinetic models. Copyright © 2012 John Wiley & Sons, Ltd.

  1. Household batteries: Evaluation of collection methods

    Energy Technology Data Exchange (ETDEWEB)

    Seeberger, D.A.

    1992-12-31

    While it is difficult to prove that a specific material is causing contamination in a landfill, tests have been conducted at waste-to-energy facilities that indicate that household batteries contribute significant amounts of heavy metals to both air emissions and ash residue. Hennepin County, MN, used a dual approach for developing and implementing a special household battery collection. Alternative collection methods were examined; test collections were conducted. The second phase examined operating and disposal policy issues. This report describes the results of the grant project, moving from a broad examination of the construction and content of batteries, to a description of the pilot collection programs, and ending with a discussion of variables affecting the cost and operation of a comprehensive battery collection program. Three out-of-state companies (PA, NY) were found that accept spent batteries; difficulties in reclaiming household batteries are discussed.

  2. Household batteries: Evaluation of collection methods

    Energy Technology Data Exchange (ETDEWEB)

    Seeberger, D.A.

    1992-01-01

    While it is difficult to prove that a specific material is causing contamination in a landfill, tests have been conducted at waste-to-energy facilities that indicate that household batteries contribute significant amounts of heavy metals to both air emissions and ash residue. Hennepin County, MN, used a dual approach for developing and implementing a special household battery collection. Alternative collection methods were examined; test collections were conducted. The second phase examined operating and disposal policy issues. This report describes the results of the grant project, moving from a broad examination of the construction and content of batteries, to a description of the pilot collection programs, and ending with a discussion of variables affecting the cost and operation of a comprehensive battery collection program. Three out-of-state companies (PA, NY) were found that accept spent batteries; difficulties in reclaiming household batteries are discussed.

  3. Analysis of methods commonly used in biomedicine for treatment versus control comparison of very small samples.

    Science.gov (United States)

    Ristić-Djurović, Jasna L; Ćirković, Saša; Mladenović, Pavle; Romčević, Nebojša; Trbovich, Alexander M

    2018-04-01

    A rough estimate indicated that use of samples of size not larger than ten is not uncommon in biomedical research and that many of such studies are limited to strong effects due to sample sizes smaller than six. For data collected from biomedical experiments it is also often unknown if mathematical requirements incorporated in the sample comparison methods are satisfied. Computer simulated experiments were used to examine performance of methods for qualitative sample comparison and its dependence on the effectiveness of exposure, effect intensity, distribution of studied parameter values in the population, and sample size. The Type I and Type II errors, their average, as well as the maximal errors were considered. The sample size 9 and the t-test method with p = 5% ensured error smaller than 5% even for weak effects. For sample sizes 6-8 the same method enabled detection of weak effects with errors smaller than 20%. If the sample sizes were 3-5, weak effects could not be detected with an acceptable error; however, the smallest maximal error in the most general case that includes weak effects is granted by the standard error of the mean method. The increase of sample size from 5 to 9 led to seven times more accurate detection of weak effects. Strong effects were detected regardless of the sample size and method used. The minimal recommended sample size for biomedical experiments is 9. Use of smaller sizes and the method of their comparison should be justified by the objective of the experiment. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. [Establishment and Management of Multicentral Collection Bio-sample Banks of Malignant Tumors from Digestive System].

    Science.gov (United States)

    Shen, Si; Shen, Junwei; Zhu, Liang; Wu, Chaoqun; Li, Dongliang; Yu, Hongyu; Qiu, Yuanyuan; Zhou, Yi

    2015-11-01

    To establish and manage of multicentral collection bio-sample banks of malignant tumors from digestive system, the paper designed a multicentral management system, established the standard operation procedures (SOPs) and leaded ten hospitals nationwide to collect tumor samples. The biobank has been established for half a year, and has collected 695 samples from patients with digestive system malignant tumor. The clinical data is full and complete, labeled in a unified way and classified to be managed. The clinical and molecular biology researches were based on the biobank, and obtained achievements. The biobank provides a research platform for malignant tumor of digestive system from different regions and of different types.

  5. Measuring DHEA-S in saliva: time of day differences and positive correlations between two different types of collection methods

    Directory of Open Access Journals (Sweden)

    Klein Laura C

    2010-07-01

    Full Text Available Abstract Background The anabolic steroid, dehydroepiandosterone sulfate (DHEA-S, is secreted from the adrenal cortex. It plays a significant role in the body as a precursor to sex steroids as well as a lesser known role in the hypothalamic pituitary adrenal axis (HPA response to stress. DHEA-S can be measured reliably in saliva, making saliva collection a valuable tool for health research because it minimizes the need for invasive sampling procedures (e.g., blood draws. Typical saliva collection methods include the use of plain cotton swab collection devices (e.g., Salivette® or passive drool. There has been some speculation that the plain saliva cotton collection device may interfere with determination of DHEA-S by enzyme immunoassay (EIA bringing this saliva collection method into question. Because of the increasing popularity of salivary biomarker research, we sought to determine whether the cotton swab interferes with DHEA-S determination through EIA techniques. Findings Fifty-six healthy young adult men and women aged 18-30 years came to the lab in the morning (0800 hrs; 14 men, 14 women or late afternoon (1600 hrs; 14 men, 14 women and provided saliva samples via cotton Salivette and passive drool. Passive drool collection was taken first to minimize particle cross contamination from the cotton swab. Samples were assayed for DHEA-S in duplicate using a commercially available kit (DSL, Inc., Webster, TX. DHEA-S levels collected via Salivette and passive drool were positively correlated (r = + 0.83, p Conclusions Results suggest that DHEA-S can be measured accurately using passive drool or cotton Salivette collection methods. Results also suggest that DHEA-S levels change across the day and that future studies need to take this time of day difference into account when measuring DHEA-S.

  6. Sample collection and preparation of biofluids and extracts for gas chromatography-mass spectrometry.

    Science.gov (United States)

    Emwas, Abdul-Hamid M; Al-Talla, Zeyad A; Kharbatia, Najeh M

    2015-01-01

    To maximize the utility of gas chromatography-mass spectrometry (GC-MS) in metabonomics research, all stages of the experimental design should be standardized, including sample collection, storage, preparation, and sample separation. Moreover, the prerequisite for any GC-MS analysis is that a compound must be volatile and thermally stable if it is to be analyzed using this technique. Since many metabolites are nonvolatile and polar in nature, they are not readily amenable to analysis by GC-MS and require initial chemical derivatization of the polar functional groups in order to reduce the polarity and to increase the thermal stability and volatility of the analytes. In this chapter, an overview is presented of the optimum approach to sample collection, storage, and preparation for gas chromatography-mass spectrometry-based metabonomics with particular focus on urine samples as example of biofluids.

  7. A numerical test of the collective coordinate method

    International Nuclear Information System (INIS)

    Dobrowolski, T.; Tatrocki, P.

    2008-01-01

    The purpose of this Letter is to compare the dynamics of the kink interacting with the imperfection which follows from the collective coordinate method with the numerical results obtained on the ground of the field theoretical model. We showed that for weekly interacting kinks the collective coordinate method works similarly well for low and extremely large speeds

  8. Performance of a hydrostatic sampler for collecting samples at the water-sediment interface in lakes

    Directory of Open Access Journals (Sweden)

    Fernando PEDROZO

    2008-02-01

    Full Text Available The water-sediment interface plays a significant role in the determination of the trophic degree of a waterbody. Numerous redox reactions take place there, resulting in the release of contaminants from the sediments to the water column. The aim of the present work was to develop an equipment for collecting samples from the water-sediment interface. Such equipment was to have a simple design, low construction cost, no depth limitations, and high levels of personal safety and to be reliable in the collection of samples. The performance of the hydrostatic sampler thus developed was tested against samples collected either remotely with a corer or directly with syringes by autonomous divers. The hydrostatic sampler permits access to depths where the costs of the traditional diving methodology are expensive, and where working conditions are dangerous for the diver. The hydrostatic sampler provides an additional means of collecting samples from the water-sediment interface, which together with pore-water samples, facilitates the investigation and understanding of chemical mechanisms in lakes, for instance, those that control the P release from sediment to the water column.

  9. Rietveld analysis using powder diffraction data with anomalous scattering effect obtained by focused beam flat sample method

    International Nuclear Information System (INIS)

    Tanaka, Masahiko; Katsuya, Yoshio; Sakata, Osami

    2016-01-01

    Focused-beam flat-sample method (FFM) is a new trial for synchrotron powder diffraction method, which is a combination of beam focusing optics, flat shape powder sample and area detectors. The method has advantages for X-ray diffraction experiments applying anomalous scattering effect (anomalous diffraction), because of 1. Absorption correction without approximation, 2. High intensity X-rays of focused incident beams and high signal noise ratio of diffracted X-rays 3. Rapid data collection with area detectors. We applied the FFM to anomalous diffraction experiments and collected synchrotron X-ray powder diffraction data of CoFe_2O_4 (inverse spinel structure) using X-rays near Fe K absorption edge, which can distinguish Co and Fe by anomalous scattering effect. We conducted Rietveld analyses with the obtained powder diffraction data and successfully determined the distribution of Co and Fe ions in CoFe_2O_4 crystal structure.

  10. The international Genome sample resource (IGSR): A worldwide collection of genome variation incorporating the 1000 Genomes Project data.

    Science.gov (United States)

    Clarke, Laura; Fairley, Susan; Zheng-Bradley, Xiangqun; Streeter, Ian; Perry, Emily; Lowy, Ernesto; Tassé, Anne-Marie; Flicek, Paul

    2017-01-04

    The International Genome Sample Resource (IGSR; http://www.internationalgenome.org) expands in data type and population diversity the resources from the 1000 Genomes Project. IGSR represents the largest open collection of human variation data and provides easy access to these resources. IGSR was established in 2015 to maintain and extend the 1000 Genomes Project data, which has been widely used as a reference set of human variation and by researchers developing analysis methods. IGSR has mapped all of the 1000 Genomes sequence to the newest human reference (GRCh38), and will release updated variant calls to ensure maximal usefulness of the existing data. IGSR is collecting new structural variation data on the 1000 Genomes samples from long read sequencing and other technologies, and will collect relevant functional data into a single comprehensive resource. IGSR is extending coverage with new populations sequenced by collaborating groups. Here, we present the new data and analysis that IGSR has made available. We have also introduced a new data portal that increases discoverability of our data-previously only browseable through our FTP site-by focusing on particular samples, populations or data sets of interest. © The Author(s) 2016. Published by Oxford University Press on behalf of Nucleic Acids Research.

  11. Tree Sampling as a Method to Assess Vapor Intrusion Potential at a Site Characterized by VOC-Contaminated Groundwater and Soil.

    Science.gov (United States)

    Wilson, Jordan L; Limmer, Matthew A; Samaranayake, V A; Schumacher, John G; Burken, Joel G

    2017-09-19

    Vapor intrusion (VI) by volatile organic compounds (VOCs) in the built environment presents a threat to human health. Traditional VI assessments are often time-, cost-, and labor-intensive; whereas traditional subsurface methods sample a relatively small volume in the subsurface and are difficult to collect within and near structures. Trees could provide a similar subsurface sample where roots act as the "sampler' and are already onsite. Regression models were developed to assess the relation between PCE concentrations in over 500 tree-core samples with PCE concentrations in over 50 groundwater and 1000 soil samples collected from a tetrachloroethylene- (PCE-) contaminated Superfund site and analyzed using gas chromatography. Results indicate that in planta concentrations are significantly and positively related to PCE concentrations in groundwater samples collected at depths less than 20 m (adjusted R 2 values greater than 0.80) and in soil samples (adjusted R 2 values greater than 0.90). Results indicate that a 30 cm diameter tree characterizes soil concentrations at depths less than 6 m over an area of 700-1600 m 2 , the volume of a typical basement. These findings indicate that tree sampling may be an appropriate method to detect contamination at shallow depths at sites with VI.

  12. Tree sampling as a method to assess vapor intrusion potential at a site characterized by VOC-contaminated groundwater and soil

    Science.gov (United States)

    Wilson, Jordan L.; Limmer, Matthew A.; Samaranayake, V. A.; Schumacher, John G.; Burken, Joel G.

    2017-01-01

    Vapor intrusion (VI) by volatile organic compounds (VOCs) in the built environment presents a threat to human health. Traditional VI assessments are often time-, cost-, and labor-intensive; whereas traditional subsurface methods sample a relatively small volume in the subsurface and are difficult to collect within and near structures. Trees could provide a similar subsurface sample where roots act as the “sampler’ and are already onsite. Regression models were developed to assess the relation between PCE concentrations in over 500 tree-core samples with PCE concentrations in over 50 groundwater and 1000 soil samples collected from a tetrachloroethylene- (PCE-) contaminated Superfund site and analyzed using gas chromatography. Results indicate that in planta concentrations are significantly and positively related to PCE concentrations in groundwater samples collected at depths less than 20 m (adjusted R2 values greater than 0.80) and in soil samples (adjusted R2 values greater than 0.90). Results indicate that a 30 cm diameter tree characterizes soil concentrations at depths less than 6 m over an area of 700–1600 m2, the volume of a typical basement. These findings indicate that tree sampling may be an appropriate method to detect contamination at shallow depths at sites with VI.

  13. Evaluation of sampling methods for measuring exposure to volatile inorganic acids in workplace air. Part 2: Sampling capacity and breakthrough tests for sodium carbonate-impregnated filters.

    Science.gov (United States)

    Demange, Martine; Oury, Véronique; Rousset, Davy

    2011-11-01

    In France, the MétroPol 009 method used to measure workplace exposure to inorganic acids, such as HF, HCl, and HNO3, consists of a closed-face cassette fitted with a prefilter to collect particles, and two sodium carbonate-impregnated filters to collect acid vapor. This method was compared with other European methods during the development of a three-part standard (ISO 21438) on the determination of inorganic acids in workplace air by ion chromatography. Results of this work, presented in a companion paper, led to a need to go deeper into the performance of the MétroPol 009 method regarding evaluation of the breakthrough of the acids, both alone and in mixtures, interference from particulate salts, the amount of sodium carbonate required to impregnate the sampling filter, the influence of sampler components, and so on. Results enabled improvements to be made to the sampling device with respect to the required amount of sodium carbonate to sample high HCl or HNO3 concentrations (500 μL of 5% Na2CO3 on each of two impregnated filters). In addition, a PVC-A filter used as a prefilter in a sampling device showed a propensity to retain HNO3 vapor so a PTFE filter was considered more suitable for use as a prefilter. Neither the material of the sampling cassette (polystyrene or polypropylene) nor the sampling flowrate (1 L/min or 2 L/min) influenced the performance of the sampling device, as a recovery of about 100% was achieved in all experiments for HNO3, HCl, and HF, as well as HNO3+HF and HNO3+HCl mixtures, over a wide range of concentrations. However, this work points to the possibility of interference between an acid and salts of other acids. For instance, interference can occur through interaction of HNO3 with chloride salts: the stronger the acid, the greater the interference. Methods based on impregnated filters are reliable for quantitative recovery of inorganic volatile acids in workplace atmosphere but are valuable only in the absence of interferents.

  14. Radioactive air sampling methods

    CERN Document Server

    Maiello, Mark L

    2010-01-01

    Although the field of radioactive air sampling has matured and evolved over decades, it has lacked a single resource that assimilates technical and background information on its many facets. Edited by experts and with contributions from top practitioners and researchers, Radioactive Air Sampling Methods provides authoritative guidance on measuring airborne radioactivity from industrial, research, and nuclear power operations, as well as naturally occuring radioactivity in the environment. Designed for industrial hygienists, air quality experts, and heath physicists, the book delves into the applied research advancing and transforming practice with improvements to measurement equipment, human dose modeling of inhaled radioactivity, and radiation safety regulations. To present a wide picture of the field, it covers the international and national standards that guide the quality of air sampling measurements and equipment. It discusses emergency response issues, including radioactive fallout and the assets used ...

  15. JSC Advanced Curation: Research and Development for Current Collections and Future Sample Return Mission Demands

    Science.gov (United States)

    Fries, M. D.; Allen, C. C.; Calaway, M. J.; Evans, C. A.; Stansbery, E. K.

    2015-01-01

    Curation of NASA's astromaterials sample collections is a demanding and evolving activity that supports valuable science from NASA missions for generations, long after the samples are returned to Earth. For example, NASA continues to loan hundreds of Apollo program samples to investigators every year and those samples are often analyzed using instruments that did not exist at the time of the Apollo missions themselves. The samples are curated in a manner that minimizes overall contamination, enabling clean, new high-sensitivity measurements and new science results over 40 years after their return to Earth. As our exploration of the Solar System progresses, upcoming and future NASA sample return missions will return new samples with stringent contamination control, sample environmental control, and Planetary Protection requirements. Therefore, an essential element of a healthy astromaterials curation program is a research and development (R&D) effort that characterizes and employs new technologies to maintain current collections and enable new missions - an Advanced Curation effort. JSC's Astromaterials Acquisition & Curation Office is continually performing Advanced Curation research, identifying and defining knowledge gaps about research, development, and validation/verification topics that are critical to support current and future NASA astromaterials sample collections. The following are highlighted knowledge gaps and research opportunities.

  16. 77 FR 52708 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2012-08-30

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Information Collection request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  17. Validation of Marek's disease diagnosis and monitoring of Marek's disease vaccines from samples collected in FTA cards.

    Science.gov (United States)

    Cortes, Aneg L; Montiel, Enrique R; Gimeno, Isabel M

    2009-12-01

    The use of Flinders Technology Associates (FTA) filter cards to quantify Marek's disease virus (MDV) DNA for the diagnosis of Marek's disease (MD) and to monitor MD vaccines was evaluated. Samples of blood (43), solid tumors (14), and feather pulp (FP; 36) collected fresh and in FTA cards were analyzed. MDV DNA load was quantified by real-time PCR. Threshold cycle (Ct) ratios were calculated for each sample by dividing the Ct value of the internal control gene (glyceraldehyde-3-phosphate dehydrogenase) by the Ct value of the MDV gene. Statistically significant correlation (P FTA cards by using Pearson's correlation test. Load of serotype 1 MDV DNA was quantified in 24 FP, 14 solid tumor, and 43 blood samples. There was a statistically significant correlation between FP (r = 0.95), solid tumor (r = 0.94), and blood (r = 0.9) samples collected fresh and in FTA cards. Load of serotype 2 MDV DNA was quantified in 17 FP samples, and the correlation between samples collected fresh and in FTA cards was also statistically significant (Pearson's coefficient, r = 0.96); load of serotype 3 MDV DNA was quantified in 36 FP samples, and correlation between samples taken fresh and in FTA cards was also statistically significant (r = 0.84). MDV DNA samples extracted 3 days (t0) and 8 months after collection (t1) were used to evaluate the stability of MDV DNA in archived samples collected in FTA cards. A statistically significant correlation was found for serotype 1 (r = 0.96), serotype 2 (r = 1), and serotype 3 (r = 0.9). The results show that FTA cards are an excellent media to collect, transport, and archive samples for MD diagnosis and to monitor MD vaccines. In addition, FTA cards are widely available, inexpensive, and adequate for the shipment of samples nationally and internationally.

  18. Collecting Protein Biomarkers in Breath Using Electret Filters: A Preliminary Method on New Technical Model and Human Study.

    Directory of Open Access Journals (Sweden)

    Wang Li

    Full Text Available Biomarkers in exhaled breath are useful for respiratory disease diagnosis in human volunteers. Conventional methods that collect non-volatile biomarkers, however, necessitate an extensive dilution and sanitation processes that lowers collection efficiencies and convenience of use. Electret filter emerged in recent decade to collect virus biomarkers in exhaled breath given its simplicity and effectiveness. To investigate the capability of electret filters to collect protein biomarkers, a model that consists of an atomizer that produces protein aerosol and an electret filter that collects albumin and carcinoembryonic antigen-a typical biomarker in lung cancer development- from the atomizer is developed. A device using electret filter as the collecting medium is designed to collect human albumin from exhaled breath of 6 volunteers. Comparison of the collecting ability between the electret filter method and other 2 reported methods is finally performed based on the amounts of albumin collected from human exhaled breath. In conclusion, a decreasing collection efficiency ranging from 17.6% to 2.3% for atomized albumin aerosol and 42% to 12.5% for atomized carcinoembryonic antigen particles is found; moreover, an optimum volume of sampling human exhaled breath ranging from 100 L to 200 L is also observed; finally, the self-designed collecting device shows a significantly better performance in collecting albumin from human exhaled breath than the exhaled breath condensate method (p0.05. In summary, electret filters are potential in collecting non-volatile biomarkers in human exhaled breath not only because it was simpler, cheaper and easier to use than traditional methods but also for its better collecting performance.

  19. Reliability of a method of sampling stream invertebrates

    CSIR Research Space (South Africa)

    Chutter, FM

    1966-05-01

    Full Text Available In field ecological studies inferences must often be drawn from dissimilarities in numbers and species of organisms found in biological samples collected at different times and under various conditions....

  20. 78 FR 79009 - Proposed Information Collection; Radiation Sampling and Exposure Records (Pertains to Underground...

    Science.gov (United States)

    2013-12-27

    ... soliciting comments concerning the proposed information collection for updating Radiation Sampling and... exposed with no adverse effects have been established and are expressed as working levels (WL). The... mandatory samplings. Records must include the sample date, location, and results, and must be retained at...

  1. Conducting Internet Research With the Transgender Population: Reaching Broad Samples and Collecting Valid Data

    Science.gov (United States)

    Miner, Michael H.; Bockting, Walter O.; Romine, Rebecca Swinburne; Raman, Sivakumaran

    2013-01-01

    Health research on transgender people has been hampered by the challenges inherent in studying a hard-to-reach, relatively small, and geographically dispersed population. The Internet has the potential to facilitate access to transgender samples large enough to permit examination of the diversity and syndemic health disparities found among this population. In this article, we describe the experiences of a team of investigators using the Internet to study HIV risk behaviors of transgender people in the United States. We developed an online instrument, recruited participants exclusively via websites frequented by members of the target population, and collected data using online quantitative survey and qualitative synchronous and asynchronous interview methods. Our experiences indicate that the Internet environment presents the investigator with some unique challenges and that commonly expressed criticisms about Internet research (e.g., lack of generalizable samples, invalid study participants, and multiple participation by the same subject) can be overcome with careful method design, usability testing, and pilot testing. The importance of both usability and pilot testing are described with respect to participant engagement and retention and the quality of data obtained online. PMID:24031157

  2. Sampling and sample processing in pesticide residue analysis.

    Science.gov (United States)

    Lehotay, Steven J; Cook, Jo Marie

    2015-05-13

    Proper sampling and sample processing in pesticide residue analysis of food and soil have always been essential to obtain accurate results, but the subject is becoming a greater concern as approximately 100 mg test portions are being analyzed with automated high-throughput analytical methods by agrochemical industry and contract laboratories. As global food trade and the importance of monitoring increase, the food industry and regulatory laboratories are also considering miniaturized high-throughput methods. In conjunction with a summary of the symposium "Residues in Food and Feed - Going from Macro to Micro: The Future of Sample Processing in Residue Analytical Methods" held at the 13th IUPAC International Congress of Pesticide Chemistry, this is an opportune time to review sampling theory and sample processing for pesticide residue analysis. If collected samples and test portions do not adequately represent the actual lot from which they came and provide meaningful results, then all costs, time, and efforts involved in implementing programs using sophisticated analytical instruments and techniques are wasted and can actually yield misleading results. This paper is designed to briefly review the often-neglected but crucial topic of sample collection and processing and put the issue into perspective for the future of pesticide residue analysis. It also emphasizes that analysts should demonstrate the validity of their sample processing approaches for the analytes/matrices of interest and encourages further studies on sampling and sample mass reduction to produce a test portion.

  3. Sampling Methods in Cardiovascular Nursing Research: An Overview.

    Science.gov (United States)

    Kandola, Damanpreet; Banner, Davina; O'Keefe-McCarthy, Sheila; Jassal, Debbie

    2014-01-01

    Cardiovascular nursing research covers a wide array of topics from health services to psychosocial patient experiences. The selection of specific participant samples is an important part of the research design and process. The sampling strategy employed is of utmost importance to ensure that a representative sample of participants is chosen. There are two main categories of sampling methods: probability and non-probability. Probability sampling is the random selection of elements from the population, where each element of the population has an equal and independent chance of being included in the sample. There are five main types of probability sampling including simple random sampling, systematic sampling, stratified sampling, cluster sampling, and multi-stage sampling. Non-probability sampling methods are those in which elements are chosen through non-random methods for inclusion into the research study and include convenience sampling, purposive sampling, and snowball sampling. Each approach offers distinct advantages and disadvantages and must be considered critically. In this research column, we provide an introduction to these key sampling techniques and draw on examples from the cardiovascular research. Understanding the differences in sampling techniques may aid nurses in effective appraisal of research literature and provide a reference pointfor nurses who engage in cardiovascular research.

  4. Comparison of semen parameters in samples collected by masturbation at a clinic and at home.

    Science.gov (United States)

    Elzanaty, Saad; Malm, Johan

    2008-06-01

    To investigate differences in semen quality between samples collected by masturbation at a clinic and at home. Cross-sectional study. Fertility center. Three hundred seventy-nine men assessed for infertility. None. Semen was analyzed according to World Health Organization guidelines. Seminal markers of epididymal (neutral alpha-glucosidase), prostatic (prostate-specific antigen and zinc), and seminal vesicle (fructose) function were measured. Two patient groups were defined according to sample collection location: at a clinic (n = 273) or at home (n = 106). Compared with clinic-collected semen, home-collected samples had statistically significantly higher values for sperm concentration, total sperm count, rapid progressive motility, and total count of progressive motility. Semen volume, proportion of normal sperm morphology, neutral alpha-glucosidase, prostate-specific antigen, zinc, and fructose did not differ significantly between groups. An abnormal sperm concentration (masturbation at home compared with at a clinic. This should be taken into consideration in infertility investigations.

  5. 76 FR 25693 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-05-05

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  6. Performance of a New HPV Cervi-Collect Collection and Transportation Kit

    Directory of Open Access Journals (Sweden)

    M. Chernesky

    2012-01-01

    Full Text Available Background. Liquid-based Pap (L-Pap media are used for Pap and human papillomavirus (HPV testing. Objectives. To compare RealTime High Risk (HR HPV testing of a new collection kit (Cervi-Collect and PreservCyt L-Pap specimens. To determine ease of use and safety of Cervi-Collect. Methods. L-Pap samples (n=203 were tested with HC2 and RealTime HR HPV and Cervi-Collect with RealTime HR HPV. Discordant samples were genotyped. Results. L-Pap and Cervi-Collect specimens tested by RealTime HR HPV showed 93.1% agreement (Kappa 0.86. RealTime HR HPV and HC2 on L-Pap had 90.3% agreement (Kappa 0.80. RealTime HR HPV on Cervi-Collect and HC2 on L-Pap showed 88.2% agreement (Kappa 0.76. Sixteen of 21 samples which were HC2 negative and RealTime HR HPV positive on L-Pap or Cervi-Collect contained HR HPV genotypes. Eleven healthcare collectors were in strong agreement on a usability and safety questionnaire. Conclusion. Cervi-Collect samples were easy to collect and showed strong agreement with L-Pap samples tested with RealTime HR HPV or HC2.

  7. A Simple Sampling Method for Estimating the Accuracy of Large Scale Record Linkage Projects.

    Science.gov (United States)

    Boyd, James H; Guiver, Tenniel; Randall, Sean M; Ferrante, Anna M; Semmens, James B; Anderson, Phil; Dickinson, Teresa

    2016-05-17

    Record linkage techniques allow different data collections to be brought together to provide a wider picture of the health status of individuals. Ensuring high linkage quality is important to guarantee the quality and integrity of research. Current methods for measuring linkage quality typically focus on precision (the proportion of incorrect links), given the difficulty of measuring the proportion of false negatives. The aim of this work is to introduce and evaluate a sampling based method to estimate both precision and recall following record linkage. In the sampling based method, record-pairs from each threshold (including those below the identified cut-off for acceptance) are sampled and clerically reviewed. These results are then applied to the entire set of record-pairs, providing estimates of false positives and false negatives. This method was evaluated on a synthetically generated dataset, where the true match status (which records belonged to the same person) was known. The sampled estimates of linkage quality were relatively close to actual linkage quality metrics calculated for the whole synthetic dataset. The precision and recall measures for seven reviewers were very consistent with little variation in the clerical assessment results (overall agreement using the Fleiss Kappa statistics was 0.601). This method presents as a possible means of accurately estimating matching quality and refining linkages in population level linkage studies. The sampling approach is especially important for large project linkages where the number of record pairs produced may be very large often running into millions.

  8. Rietveld analysis using powder diffraction data with anomalous scattering effect obtained by focused beam flat sample method

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Masahiko, E-mail: masahiko@spring8.or.jp; Katsuya, Yoshio, E-mail: katsuya@spring8.or.jp; Sakata, Osami, E-mail: SAKATA.Osami@nims.go.jp [Synchrotron X-ray Station at SPring-8, National Institute for Materials Science 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan)

    2016-07-27

    Focused-beam flat-sample method (FFM) is a new trial for synchrotron powder diffraction method, which is a combination of beam focusing optics, flat shape powder sample and area detectors. The method has advantages for X-ray diffraction experiments applying anomalous scattering effect (anomalous diffraction), because of 1. Absorption correction without approximation, 2. High intensity X-rays of focused incident beams and high signal noise ratio of diffracted X-rays 3. Rapid data collection with area detectors. We applied the FFM to anomalous diffraction experiments and collected synchrotron X-ray powder diffraction data of CoFe{sub 2}O{sub 4} (inverse spinel structure) using X-rays near Fe K absorption edge, which can distinguish Co and Fe by anomalous scattering effect. We conducted Rietveld analyses with the obtained powder diffraction data and successfully determined the distribution of Co and Fe ions in CoFe{sub 2}O{sub 4} crystal structure.

  9. Use of self-collected capillary blood samples for islet autoantibody screening in relatives: a feasibility and acceptability study.

    Science.gov (United States)

    Liu, Y; Rafkin, L E; Matheson, D; Henderson, C; Boulware, D; Besser, R E J; Ferrara, C; Yu, L; Steck, A K; Bingley, P J

    2017-07-01

    To evaluate the feasibility of using self-collected capillary blood samples for islet autoantibody testing to identify risk in relatives of people with Type 1 diabetes. Participants were recruited via the observational TrialNet Pathway to Prevention study, which screens and monitors relatives of people with Type 1 diabetes for islet autoantibodies. Relatives were sent kits for capillary blood collection, with written instructions, an online instructional video link and a questionnaire. Sera from capillary blood samples were tested for autoantibodies to glutamic acid decarboxylase, islet antigen-2, insulin and zinc transporter 8. 'Successful' sample collection was defined as obtaining sufficient volume and quality to provide definitive autoantibody results, including confirmation of positive results by repeat assay. In 240 relatives who returned samples, the median (range) age was 15.5 (1-49) years and 51% were male. Of these samples, 98% were sufficient for glutamic acid decarboxylase, islet antigen-2 and zinc transporter 8 autoantibody testing and 84% for insulin autoantibody testing and complete autoantibody screen. The upper 90% confidence bound for unsuccessful collection was 4.4% for glutamic acid decarboxylase, islet antigen-2 and/or zinc transporter 8 autoantibody assays, and 19.3% for insulin autoantibodies. Despite 43% of 220 questionnaire respondents finding capillary blood collection uncomfortable or painful, 82% preferred home self-collection of capillary blood samples compared with outpatient venepuncture (90% of those aged 18 years). The perceived difficulty of collecting capillary blood samples did not affect success rate. Self-collected capillary blood sampling offers a feasible alternative to venous sampling, with the potential to facilitate autoantibody screening for Type 1 diabetes risk. © 2017 Diabetes UK.

  10. New Zealand guidelines for the collection of groundwater samples for chemical and isotopic analyses

    International Nuclear Information System (INIS)

    Rosen, M.R.; Cameron, S.G.; Reeves, R.R.; Taylor, C.B.

    1999-01-01

    Chemical and isotopic analyses of groundwater are important tools for differentiating between the natural composition and human-induced contaminants of groundwater. A comprehensive suite of inorganic water chemical analyses is necessary to characterise waters. The geology of New Zealand is diverse, so it is impractical to characterise a ''typical'' groundwater chemical composition. Each aquifer system should be evaluated individually because the major dissolved species contain useful information about the pathways of water through the soil zone into the aquifer. Analyses of major ions such as chloride, nitrate, potassium and sulphate often give indication of septic systems and agricultural contamination. The minor ions, while most are not considered contaminants, are often indicators of human activity. Iron and manganese are good indicators of Eh potential, which is an important control on the mobility of many heavy metals. The inexpensive inorganic chemical analytical suite should be used as a guide to advisability of more expensive contaminant testing. The purpose of this manual is to provide consistent groundwater sampling guidelines for use throughout New Zealand. Sinton's (1998) guide to groundwater sampling techniques provided a sound basis for the accurate collection of groundwater samples. However Sinton did not address sampling materials and techniques for the collection of samples for ultra trace component analysis or the collection of environmental isotope samples. These important aspects of groundwater sampling have been included in this updated manual. (author). 30 refs., 12 figs., 5 tabs., 1 appendix

  11. Comparison of Saliva Collection Methods in Children with High-Functioning Autism Spectrum Disorders: Acceptability and Recovery of Cortisol

    Science.gov (United States)

    Putnam, Susan K.; Lopata, Christopher; Fox, Jeffery D.; Thomeer, Marcus L.; Rodgers, Jonathan D.; Volker, Martin A.; Lee, Gloria K.; Neilans, Erik G.; Werth, Jilynn

    2012-01-01

    This study compared cortisol concentrations yielded using three saliva collection methods (passive drool, salivette, and sorbette) in both in vitro and in vivo conditions, as well as method acceptability for a sample of children (n = 39) with High Functioning Autism Spectrum Disorders. No cortisol concentration differences were observed between…

  12. On-capillary sample cleanup method for the electrophoretic determination of carbohydrates in juice samples.

    Science.gov (United States)

    Morales-Cid, Gabriel; Simonet, Bartolomé M; Cárdenas, Soledad; Valcárcel, Miguel

    2007-05-01

    On many occasions, sample treatment is a critical step in electrophoretic analysis. As an alternative to batch procedures, in this work, a new strategy is presented with a view to develop an on-capillary sample cleanup method. This strategy is based on the partial filling of the capillary with carboxylated single-walled carbon nanotube (c-SWNT). The nanoparticles retain interferences from the matrix allowing the determination and quantification of carbohydrates (viz glucose, maltose and fructose). The precision of the method for the analysis of real samples ranged from 5.3 to 6.4%. The proposed method was compared with a method based on a batch filtration of the juice sample through diatomaceous earth and further electrophoretic determination. This method was also validated in this work. The RSD for this other method ranged from 5.1 to 6%. The results obtained by both methods were statistically comparable demonstrating the accuracy of the proposed methods and their effectiveness. Electrophoretic separation of carbohydrates was achieved using 200 mM borate solution as a buffer at pH 9.5 and applying 15 kV. During separation, the capillary temperature was kept constant at 40 degrees C. For the on-capillary cleanup method, a solution containing 50 mg/L of c-SWNTs prepared in 300 mM borate solution at pH 9.5 was introduced for 60 s into the capillary just before sample introduction. For the electrophoretic analysis of samples cleaned in batch with diatomaceous earth, it is also recommended to introduce into the capillary, just before the sample, a 300 mM borate solution as it enhances the sensitivity and electrophoretic resolution.

  13. Collective motion and the generator coordinate method

    International Nuclear Information System (INIS)

    Passos, E.J.V. de

    1981-01-01

    The generator coordinate method is used to construct a collective subspace of the many-body Hylbert space. The construction is based on the analysis of the properties of the overlaps of the generator states. Some well-known misbehaviours of the generator coordinate weight functions are clearly identified as of kinematical origin. A standard orthonormal representation in the collective subspace is introduced which eliminates them. It is also indicated how appropriate collective dynamical variables can be defined a posteriori. To illustrate the properties of the collective subspaces applications are made to a) translational invariant overlap kernels b) to one and two-conjugate parameter families of generator states. (Author) [pt

  14. Analysis of Samples Collected from the Surface of Interim Storage Canisters at Calvert Cliffs in June 2017: Revision 01.

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Charles R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schindelholz, Eric John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-11-01

    In June 2017, dust and salt samples were collected from the surface of Spent Nuclear Fuel (SNF) dry storage canisters at the Calvert Cliffs Nuclear Power Plant. The samples were delivered to Sandia National laboratories for analysis. Two types of samples were collected: filter-backed Scotch-Brite TM pads were used to collect dry dust samples for characterization of salt and dust morphologies and distributions; and Saltsmart TM test strips were used to collect soluble salts for determining salt surface loadings per unit area. After collection, the samples were sealed into plastic sleeves for shipping. Condensation within the sleeves containing the Scotch-Brite TM samples remobilized the salts, rendering them ineffective for the intended purpose, and also led to mold growth, further compromising the samples; for these reasons, the samples were not analyzed. The SaltSmart TM samples were unaffected and were analyzed by ion chromatography for major anions and cations. The results of those analyses are presented here.

  15. Present status of NMCC and sample preparation method for bio-samples

    International Nuclear Information System (INIS)

    Futatsugawa, S.; Hatakeyama, S.; Saitou, S.; Sera, K.

    1993-01-01

    In NMCC(Nishina Memorial Cyclotron Center) we are doing researches on PET of nuclear medicine (Positron Emission Computed Tomography) and PIXE analysis (Particle Induced X-ray Emission) using a small cyclotron of compactly designed. The NMCC facilities have been opened to researchers of other institutions since April 1993. The present status of NMCC is described. Bio-samples (medical samples, plants, animals and environmental samples) have mainly been analyzed by PIXE in NMCC. Small amounts of bio-samples for PIXE are decomposed quickly and easily in a sealed PTFE (polytetrafluoroethylene) vessel with a microwave oven. This sample preparation method of bio-samples also is described. (author)

  16. Collective estimation of multiple bivariate density functions with application to angular-sampling-based protein loop modeling

    KAUST Repository

    Maadooliat, Mehdi

    2015-10-21

    This paper develops a method for simultaneous estimation of density functions for a collection of populations of protein backbone angle pairs using a data-driven, shared basis that is constructed by bivariate spline functions defined on a triangulation of the bivariate domain. The circular nature of angular data is taken into account by imposing appropriate smoothness constraints across boundaries of the triangles. Maximum penalized likelihood is used to fit the model and an alternating blockwise Newton-type algorithm is developed for computation. A simulation study shows that the collective estimation approach is statistically more efficient than estimating the densities individually. The proposed method was used to estimate neighbor-dependent distributions of protein backbone dihedral angles (i.e., Ramachandran distributions). The estimated distributions were applied to protein loop modeling, one of the most challenging open problems in protein structure prediction, by feeding them into an angular-sampling-based loop structure prediction framework. Our estimated distributions compared favorably to the Ramachandran distributions estimated by fitting a hierarchical Dirichlet process model; and in particular, our distributions showed significant improvements on the hard cases where existing methods do not work well.

  17. Collective estimation of multiple bivariate density functions with application to angular-sampling-based protein loop modeling

    KAUST Repository

    Maadooliat, Mehdi; Zhou, Lan; Najibi, Seyed Morteza; Gao, Xin; Huang, Jianhua Z.

    2015-01-01

    This paper develops a method for simultaneous estimation of density functions for a collection of populations of protein backbone angle pairs using a data-driven, shared basis that is constructed by bivariate spline functions defined on a triangulation of the bivariate domain. The circular nature of angular data is taken into account by imposing appropriate smoothness constraints across boundaries of the triangles. Maximum penalized likelihood is used to fit the model and an alternating blockwise Newton-type algorithm is developed for computation. A simulation study shows that the collective estimation approach is statistically more efficient than estimating the densities individually. The proposed method was used to estimate neighbor-dependent distributions of protein backbone dihedral angles (i.e., Ramachandran distributions). The estimated distributions were applied to protein loop modeling, one of the most challenging open problems in protein structure prediction, by feeding them into an angular-sampling-based loop structure prediction framework. Our estimated distributions compared favorably to the Ramachandran distributions estimated by fitting a hierarchical Dirichlet process model; and in particular, our distributions showed significant improvements on the hard cases where existing methods do not work well.

  18. Randomized Comparison of Two Vaginal Self-Sampling Methods for Human Papillomavirus Detection: Dry Swab versus FTA Cartridge.

    Directory of Open Access Journals (Sweden)

    Rosa Catarino

    Full Text Available Human papillomavirus (HPV self-sampling (self-HPV is valuable in cervical cancer screening. HPV testing is usually performed on physician-collected cervical smears stored in liquid-based medium. Dry filters and swabs are an alternative. We evaluated the adequacy of self-HPV using two dry storage and transport devices, the FTA cartridge and swab.A total of 130 women performed two consecutive self-HPV samples. Randomization determined which of the two tests was performed first: self-HPV using dry swabs (s-DRY or vaginal specimen collection using a cytobrush applied to an FTA cartridge (s-FTA. After self-HPV, a physician collected a cervical sample using liquid-based medium (Dr-WET. HPV types were identified by real-time PCR. Agreement between collection methods was measured using the kappa statistic.HPV prevalence for high-risk types was 62.3% (95%CI: 53.7-70.2 detected by s-DRY, 56.2% (95%CI: 47.6-64.4 by Dr-WET, and 54.6% (95%CI: 46.1-62.9 by s-FTA. There was overall agreement of 70.8% between s-FTA and s-DRY samples (kappa = 0.34, and of 82.3% between self-HPV and Dr-WET samples (kappa = 0.56. Detection sensitivities for low-grade squamous intraepithelial lesion or worse (LSIL+ were: 64.0% (95%CI: 44.5-79.8 for s-FTA, 84.6% (95%CI: 66.5-93.9 for s-DRY, and 76.9% (95%CI: 58.0-89.0 for Dr-WET. The preferred self-collection method among patients was s-DRY (40.8% vs. 15.4%. Regarding costs, FTA card was five times more expensive than the swab (~5 US dollars (USD/per card vs. ~1 USD/per swab.Self-HPV using dry swabs is sensitive for detecting LSIL+ and less expensive than s-FTA.International Standard Randomized Controlled Trial Number (ISRCTN: 43310942.

  19. Evaluation of common methods for sampling invertebrate pollinator assemblages: net sampling out-perform pan traps.

    Science.gov (United States)

    Popic, Tony J; Davila, Yvonne C; Wardle, Glenda M

    2013-01-01

    Methods for sampling ecological assemblages strive to be efficient, repeatable, and representative. Unknowingly, common methods may be limited in terms of revealing species function and so of less value for comparative studies. The global decline in pollination services has stimulated surveys of flower-visiting invertebrates, using pan traps and net sampling. We explore the relative merits of these two methods in terms of species discovery, quantifying abundance, function, and composition, and responses of species to changing floral resources. Using a spatially-nested design we sampled across a 5000 km(2) area of arid grasslands, including 432 hours of net sampling and 1296 pan trap-days, between June 2010 and July 2011. Net sampling yielded 22% more species and 30% higher abundance than pan traps, and better reflected the spatio-temporal variation of floral resources. Species composition differed significantly between methods; from 436 total species, 25% were sampled by both methods, 50% only by nets, and the remaining 25% only by pans. Apart from being less comprehensive, if pan traps do not sample flower-visitors, the link to pollination is questionable. By contrast, net sampling functionally linked species to pollination through behavioural observations of flower-visitation interaction frequency. Netted specimens are also necessary for evidence of pollen transport. Benefits of net-based sampling outweighed minor differences in overall sampling effort. As pan traps and net sampling methods are not equivalent for sampling invertebrate-flower interactions, we recommend net sampling of invertebrate pollinator assemblages, especially if datasets are intended to document declines in pollination and guide measures to retain this important ecosystem service.

  20. Direct sampling methods for inverse elastic scattering problems

    Science.gov (United States)

    Ji, Xia; Liu, Xiaodong; Xi, Yingxia

    2018-03-01

    We consider the inverse elastic scattering of incident plane compressional and shear waves from the knowledge of the far field patterns. Specifically, three direct sampling methods for location and shape reconstruction are proposed using the different component of the far field patterns. Only inner products are involved in the computation, thus the novel sampling methods are very simple and fast to be implemented. With the help of the factorization of the far field operator, we give a lower bound of the proposed indicator functionals for sampling points inside the scatterers. While for the sampling points outside the scatterers, we show that the indicator functionals decay like the Bessel functions as the sampling point goes away from the boundary of the scatterers. We also show that the proposed indicator functionals continuously dependent on the far field patterns, which further implies that the novel sampling methods are extremely stable with respect to data error. For the case when the observation directions are restricted into the limited aperture, we firstly introduce some data retrieval techniques to obtain those data that can not be measured directly and then use the proposed direct sampling methods for location and shape reconstructions. Finally, some numerical simulations in two dimensions are conducted with noisy data, and the results further verify the effectiveness and robustness of the proposed sampling methods, even for multiple multiscale cases and limited-aperture problems.

  1. Procedures for the collection and preservation of groundwater and surface water samples and for the installation of monitoring wells

    International Nuclear Information System (INIS)

    Korte, N.; Kearl, P.

    1984-01-01

    Proper sampling procedures are essential for a successful water-quality monitoring program. It must be emphasized, however, that it is impossible to maintain absolutely in-situ conditions when collecting and preserving a water sample, whether from a flowing stream or an aquifer. Consequently, the most that can reasonably be expected is to collect a best possible sample with minimal disturbance. This document describes procedures for installing monitoring wells and for collecting samples of surface water and groundwater. The discussion of monitoring wells includes mention of multilevel sampling and a general overview of vadose-zone monitoring. Guidelines for well installation are presented in detail. The discussion of water-sample collection contains evaluations of sampling pumps, filtration equipment, and sample containers. Sample-preservation techniques, as published by several government and private sources, are reviewed. Finally, step-by-step procedures for collection of water samples are provided; these procedures address such considerations as necessary equipment, field operations, and written documentation. Separate procedures are also included for the collection of samples for determination of sulfide and for reactive aluminum. The report concludes with a brief discussion of adverse sampling, conditions that may significantly affect the quality of the data. Appendix A presents a rationale for the development and use of statistical considerations in water sampling to ensure a more complete water quality monitoring program. 51 references, 9 figures, 4 tables

  2. Assessment of different methods of bovine oocytes collection, maturation and in vitro fertilization of abattoir specimens

    Directory of Open Access Journals (Sweden)

    W.M. Saleh

    2017-06-01

    Full Text Available The aim of this study is designed to evaluate the best methods for cow oocytes collection from abattoir specimens which is the cheapest, easily obtained and bulky number. Forty five fresh cow genitalia specimens and testicle were collected directly after slaughter from Al-Shoáalla abattoir north-west of Baghdad the capital early morning, transported in cool box under (4-8 °C to the laboratory of theriogenology in the College of Veterinary Medicine/Baghdad University during the period from November 2016 to February 2017. Ovaries were separated from the surrounding tissues, washed thoroughly with dis. water repeatedly, then with normal saline and finally with MEM medium containing Antibiotics and Nystatin for contaminant elimination. Oocytes were collected with four methods aspiration, slashing, slicing after aspiration and slicing. The result showed that; the collected oocytes were 55, 68, 87 and 106 oocytes respectively; slicing methods yield more oocytes count. Period of time between slaughtering and samples processing significantly affect oocytes collected percentage and quality, periods as 2, 6, 12 and 24 hours yield 75%, 68%, 61% and 55% oocytes counts of good, fair, poor to aged and bad quality oocytes respectively. Two hours period yield an elevated oocytes count with good quality. Maturation index of oocytes according to the type of collected methods showed 44, 37, 39 and 42 with 12, 8, 6 and 6 good oocyte quality for the four methods respectively. In conclusion slicing methods yield more oocytes count with a moderate quality and embryos production while aspiration methods yield a moderate oocytes count with an elevated quality and good embryos production.

  3. Multi-element composition of historical lichen collections and bark samples, indicators of changing atmospheric conditions

    Science.gov (United States)

    Purvis, O. W.; Chimonides, P. D. J.; Jeffries, T. E.; Jones, G. C.; Rusu, A.-M.; Read, H.

    Thirty six element signatures were compared in historical Parmelia sulcata samples from the Natural History Museum herbarium collected over the period 1797-1967 with those recorded in the same species and tree bark sampled in 2000 from Burnham Beeches, lying 40 km west of London. Nineteen elements reached highest concentrations in herbarium samples, consistent with a pollution legacy and dust contamination in the herbarium. Healthy Parmelia sampled east and down-wind of London at a farm during peak SO 2 emissions in 1967 contained highest V, Ni, Zn, Cd, Se, Ge contents, supporting derivation from fuel combustion; the same sample was previously determined as having a low δ34S and high S and N contents. Lowest V, Co, Ni, Cu, Zn, Sn, Ba, Pb, Mo, Sb, Li, B, Cs, U, Th, Ga contents were recorded in a sample with a high δ34S and low S content collected in 1887 from a remote region from Ross-shire, Scotland. Se and Cd enrichment, never-the-less suggest a transboundary pollution influence. Lichen Pb concentrations from Burnham Beeches were amongst the lowest recorded in spite of lichens being collected close to roads. Herbarium samples help interpret changes in element deposition where few data exist, in spite of dust contamination.

  4. Comparison of chemical constituents and antimicrobial activities of three essential oils from three different brands' clove samples collected from Gulf region

    Directory of Open Access Journals (Sweden)

    Mohammad Amzad Hossain

    2014-08-01

    Full Text Available Objective: To analyze three essential oils isolated from three different brands' clove samples collected from Gulf region and tested their antimicrobial activities. Methods: The essential oils were isolated from powder clove samples by water distillation method and analyzed and identified by gas chromatography-mass spectrometry. Antimicrobial activities of the three isolated essential oils were calculated on the diameter inhibition zone by disc diffusion method against three bacterial strains with amoxicillin standard. Results: Twenty-eight, twenty-two and twenty-six chemical ingredients with high percentage were characterized based on gas chromatography retention time from clove essential oils collected from Saudi Arabia, United Arab Emirate and Jordan. The highest antimicrobial activity was obtained from Saudi Arab against Escherichia coli, Pseudomonus aeruginosa and Staphylococcus aureus and the lowest was from Jordan and the order of antimicrobial activity was Saudi Arabia>United Arab Emirate>Jordan. Conclusions: All three essential oils from Gulf region are containing very portent chemical ingredients and it could be used as medicine or antibiotics for different aliments.

  5. Rapid column extraction method for actinides and strontium in fish and other animal tissue samples

    International Nuclear Information System (INIS)

    Maxwell III, S.L.; Faison, D.M.

    2008-01-01

    The analysis of actinides and radiostrontium in animal tissue samples is very important for environmental monitoring. There is a need to measure actinide isotopes and strontium with very low detection limits in animal tissue samples, including fish, deer, hogs, beef and shellfish. A new, rapid separation method has been developed that allows the measurement of plutonium, neptunium, uranium, americium, curium and strontium isotopes in large animal tissue samples (100-200 g) with high chemical recoveries and effective removal of matrix interferences. This method uses stacked TEVA Resin R , TRU Resin R and DGA Resin R cartridges from Eichrom Technologies (Darien, IL, USA) that allows the rapid separation of plutonium (Pu), neptunium (Np), uranium (U), americium (Am), and curium (Cm) using a single multi-stage column combined with alphaspectrometry. Strontium is collected on Sr Resin R from Eichrom Technologies (Darien, IL, USA). After acid digestion and furnace heating of the animal tissue samples, the actinides and 89/90 Sr are separated using column extraction chromatography. This method has been shown to be effective over a wide range of animal tissue matrices. Vacuum box cartridge technology with rapid flow rates is used to minimize sample preparation time. (author)

  6. Methods for efficient analysis of tocopherols, tocotrienols and their metabolites in animal samples with HPLC-EC

    Directory of Open Access Journals (Sweden)

    Mao-Jung Lee

    2018-01-01

    Full Text Available Tocopherols and tocotrienols, collectively known as vitamin E, have received a great deal of attention because of their interesting biological activities. In the present study, we reexamined and improved previous methods of sample preparation and the conditions of high-performance liquid chromatography for more accurate quantification of tocopherols, tocotrienols and their major chain-degradation metabolites. For the analysis of serum tocopherols/tocotrienols, we reconfirmed our method of mixing serum with ethanol followed by hexane extraction. For the analysis of tissue samples, we improved our methods by extracting tocopherols/tocotrienols directly from tissue homogenate with hexane. For the analysis of total amounts (conjugated and unconjugated forms of side-chain degradation metabolites, the samples need to be deconjugated by incubating with β-glucuronidase and sulfatase; serum samples can be directly used for the incubation, whereas for tissue homogenates a pre-deproteination step is needed. The present methods are sensitive, convenient and are suitable for the determination of different forms of vitamin E and their metabolites in animal and human studies. Results from the analysis of serum, liver, kidney, lung and urine samples from mice that had been treated with mixtures of tocotrienols and tocopherols are presented as examples.

  7. Sampling Methods for Wallenius' and Fisher's Noncentral Hypergeometric Distributions

    DEFF Research Database (Denmark)

    Fog, Agner

    2008-01-01

    the mode, ratio-of-uniforms rejection method, and rejection by sampling in the tau domain. Methods for the multivariate distributions include: simulation of urn experiments, conditional method, Gibbs sampling, and Metropolis-Hastings sampling. These methods are useful for Monte Carlo simulation of models...... of biased sampling and models of evolution and for calculating moments and quantiles of the distributions.......Several methods for generating variates with univariate and multivariate Wallenius' and Fisher's noncentral hypergeometric distributions are developed. Methods for the univariate distributions include: simulation of urn experiments, inversion by binary search, inversion by chop-down search from...

  8. Prevalence of antibiotic resistant Staphylococcus aureus from raw milk samples collected from the local vendors in the region of Tirupathi, India

    Directory of Open Access Journals (Sweden)

    Sudhanthirakodi Sudhanthiramani

    2015-04-01

    Full Text Available Aim: The study was carried out with the aim to identify the suitability of the milk for consumer use with special reference to Staphylococcus aureus from milk samples collected from various local vendors and determine the antibiotic susceptibility pattern of those positive isolates. Materials and Methods: A total of 110 milk samples were collected from the local milk vendors in and around Tirupathi region of India. All the samples were enriched with buffered peptone water in 9:1 ratio and the then inoculated on baird parker agar medium with added 2% egg yolk tellurite emulsion as selective medium for S.aureus and confirmed with mannitol salt agar, Gram’s staining and biochemical tests. The typical cultural characters with coagulase-positive samples were taken as positive samples the positive samples were tested for antibiotic susceptibility with 10 different antibiotics by employing disc diffusion method. Results: Prevalence of coagulase-positive S. aureus was 39.09% (43/110 from the milk samples. The antibiotic susceptibility test of positive isolates showed high resistant toward penicillin G 37/43 (86.04% and ampicillin 32/43 (74.42%, and also showed resistant to methicillin 6/43 (13.95%, cephalothin 6/43 (13.95%, tetracycline 6/43 (13.95%, ciprofloxacin 4/43 (9.30%, enrofloxacin 3/43 (6.97%, cefoxitin 2/43 (4.65%, gentamicin 2/43 (4.65%, and co-trimoxazole 2/43 (4.65%. Many individual isolates showed resistant against two or more antibiotics in our study. Conclusion: The above study results show that the milk samples collected from local vendor having S. aureus, which can induce disease condition as well as antibiotic resistant to the humans particularly young children and old age peoples by means of consumption of raw milk and its products. This is the public health issue, which needs to be solved by educating the local vendors regarding health problems related to unhygienic milk supply and make the awareness among the consumers about this

  9. Ellog Auger Drilling -"3-in-one" method for hydrogeological data collection

    DEFF Research Database (Denmark)

    Sørensen, Kurt; Larsen, Flemming

    1999-01-01

    The Ellog auger drilling method is an integrated approach for hydrogeological data collection during auger drilling in unconsolidated sediments. The drill stem is a continuous flight, hollow-stem auger with integrated electrical and gamma logging tools. The geophysical logging is performed...... continuously while drilling. Data processing is carried out in the field, and recorded log features are displayed as drilling advances. A slotted section in the stem, above the cutting head, allows anaerobic water and soil-gas samples to be taken at depth intervals of approximately 0.2 m. The logging, water......, and gas sampling instrumentation in the drill stem is removable; therefore, when the drill stem is pulled back, piezometers can be installed through the hollow stem. Cores of sediments can subsequently be taken continuously using a technique in which the drill bit can be reinserted after each coring...

  10. Evaluation of common methods for sampling invertebrate pollinator assemblages: net sampling out-perform pan traps.

    Directory of Open Access Journals (Sweden)

    Tony J Popic

    Full Text Available Methods for sampling ecological assemblages strive to be efficient, repeatable, and representative. Unknowingly, common methods may be limited in terms of revealing species function and so of less value for comparative studies. The global decline in pollination services has stimulated surveys of flower-visiting invertebrates, using pan traps and net sampling. We explore the relative merits of these two methods in terms of species discovery, quantifying abundance, function, and composition, and responses of species to changing floral resources. Using a spatially-nested design we sampled across a 5000 km(2 area of arid grasslands, including 432 hours of net sampling and 1296 pan trap-days, between June 2010 and July 2011. Net sampling yielded 22% more species and 30% higher abundance than pan traps, and better reflected the spatio-temporal variation of floral resources. Species composition differed significantly between methods; from 436 total species, 25% were sampled by both methods, 50% only by nets, and the remaining 25% only by pans. Apart from being less comprehensive, if pan traps do not sample flower-visitors, the link to pollination is questionable. By contrast, net sampling functionally linked species to pollination through behavioural observations of flower-visitation interaction frequency. Netted specimens are also necessary for evidence of pollen transport. Benefits of net-based sampling outweighed minor differences in overall sampling effort. As pan traps and net sampling methods are not equivalent for sampling invertebrate-flower interactions, we recommend net sampling of invertebrate pollinator assemblages, especially if datasets are intended to document declines in pollination and guide measures to retain this important ecosystem service.

  11. Isolation and molecular identification of Mycobacterium from commercially available pasteurized milk and raw milk samples collected from two infected cattle farms in Alborz Province, Iran.

    Science.gov (United States)

    Eftekhari, Mohsen; Mosavari, Nader

    2016-12-01

    Mycobacterium avium subsp. paratuberculosis (MAP) is an etiological agent of Johne's disease in ruminant including cattle, sheep and goats. This disease is considered an economically important disease in cattle. Animals with paratuberculosis shed viable MAP, particularly in their milk and feces. MAP may be involved in the development of Crohn's disease in humans through the consumption of contaminated milk and dairy products. Common methods of pasteurization are not enough to kill all MAP present in the milk and the bacterium has been isolated from raw milk, pasteurized milk and cheese samples. The purpose of this study was to evaluate two different methods for detecting MAP in milk and milk products. We analyzed the commonly used methods such as culture and molecular biology for identification of MAP. For this study, 50 milk samples from cows with suspected Johne's disease located in two dairy farms and 10 commercially available pasteurized milk and cheese samples from the market in Karaj city, Iran were selected. Following Ziehl-Neelsen staining of milk samples, direct microscopic detection of MAP was performed. All milk samples were centrifuged, and the concentrated samples were decontaminated using hexadecyl pyridinium chloride. The decontaminated milk suspensions were washed three times by centrifuging, and the collected filtrates were cultivated on Herrold's egg yolk medium enriched by Mycobactin J. Finally, identification and confirmation of isolates to MAP was performed using IS900-nested polymerase chain reaction (PCR). According to the obtained results by culture and PCR methods, none of the pasteurized milk and cheese samples showed the presence of MAP. However, 10% of the tested raw milk samples collected from suspected cattle showed the presence of MAP by both culture and PCR methods. Culture and PCR methods are reliable for identification of MAP from milk samples. Copyright © 2016.

  12. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1993-03-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) provides applicable methods in use by. the US Department of Energy (DOE) laboratories for sampling and analyzing constituents of waste and environmental samples. The development of DOE Methods is supported by the Laboratory Management Division (LMD) of the DOE. This document contains chapters and methods that are proposed for use in evaluating components of DOE environmental and waste management samples. DOE Methods is a resource intended to support sampling and analytical activities that will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the US Environmental Protection Agency (EPA), or others

  13. DOE methods for evaluating environmental and waste management samples.

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S C; McCulloch, M; Thomas, B L; Riley, R G; Sklarew, D S; Mong, G M; Fadeff, S K [eds.; Pacific Northwest Lab., Richland, WA (United States)

    1994-04-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) provides applicable methods in use by. the US Department of Energy (DOE) laboratories for sampling and analyzing constituents of waste and environmental samples. The development of DOE Methods is supported by the Laboratory Management Division (LMD) of the DOE. This document contains chapters and methods that are proposed for use in evaluating components of DOE environmental and waste management samples. DOE Methods is a resource intended to support sampling and analytical activities that will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the US Environmental Protection Agency (EPA), or others.

  14. [Comparison of the determination of cyclosporin-A in blood samples collected on filter paper and by the ordinary technique].

    Science.gov (United States)

    Azevedo, L S; Manrique, R; Sabbaga, E

    1995-01-01

    Monitoring cyclosporin-A (CsA) blood levels is of utmost importance for the rational use of this drug. Although many centers perform transplants, in Brazil there are few laboratories able to measure CsA blood levels. Therefore making blood samples reach the laboratory emerged as a problem. Collection of blood on filter paper has been a technique used for a long time in special cases. PURPOSE--To confirm the usefulness of measuring CsA blood levels in blood samples collected on filter paper and in the usual way. METHOD--We studied twenty renal cadaver kidney recipients who were receiving CsA, azathioprine and prednisone. Ninety five blood samples were collected and divided into two aliquots. One of them was sent routinely to one laboratory to perform whole blood CsA measurements. From the other aliquot, 20 microliters were pipetted on filter paper. When dried they were mailed to the other laboratory, where, after elution, CsA was measured. In both cases radioimmunoassay with polyclonal antibody was used. RESULTS--Linear correlation between both measurements revealed r = 0.81 with no statistical difference. CONCLUSION--The technique showed to be useful in clinical practice. In countries with continental size, as Brazil, it may be very helpful.

  15. DNA cards: determinants of DNA yield and quality in collecting genetic samples for pharmacogenetic studies.

    Science.gov (United States)

    Mas, Sergi; Crescenti, Anna; Gassó, Patricia; Vidal-Taboada, Jose M; Lafuente, Amalia

    2007-08-01

    As pharmacogenetic studies frequently require establishment of DNA banks containing large cohorts with multi-centric designs, inexpensive methods for collecting and storing high-quality DNA are needed. The aims of this study were two-fold: to compare the amount and quality of DNA obtained from two different DNA cards (IsoCode Cards or FTA Classic Cards, Whatman plc, Brentford, Middlesex, UK); and to evaluate the effects of time and storage temperature, as well as the influence of anticoagulant ethylenediaminetetraacetic acid on the DNA elution procedure. The samples were genotyped by several methods typically used in pharmacogenetic studies: multiplex PCR, PCR-restriction fragment length polymorphism, single nucleotide primer extension, and allelic discrimination assay. In addition, they were amplified by whole genome amplification to increase genomic DNA mass. Time, storage temperature and ethylenediaminetetraacetic acid had no significant effects on either DNA card. This study reveals the importance of drying blood spots prior to isolation to avoid haemoglobin interference. Moreover, our results demonstrate that re-isolation protocols could be applied to increase the amount of DNA recovered. The samples analysed were accurately genotyped with all the methods examined herein. In conclusion, our study shows that both DNA cards, IsoCode Cards and FTA Classic Cards, facilitate genetic and pharmacogenetic testing for routine clinical practice.

  16. A method for estimating radioactive cesium concentrations in cattle blood using urine samples.

    Science.gov (United States)

    Sato, Itaru; Yamagishi, Ryoma; Sasaki, Jun; Satoh, Hiroshi; Miura, Kiyoshi; Kikuchi, Kaoru; Otani, Kumiko; Okada, Keiji

    2017-12-01

    In the region contaminated by the Fukushima nuclear accident, radioactive contamination of live cattle should be checked before slaughter. In this study, we establish a precise method for estimating radioactive cesium concentrations in cattle blood using urine samples. Blood and urine samples were collected from a total of 71 cattle on two farms in the 'difficult-to-return zone'. Urine 137 Cs, specific gravity, electrical conductivity, pH, sodium, potassium, calcium, and creatinine were measured and various estimation methods for blood 137 Cs were tested. The average error rate of the estimation was 54.2% without correction. Correcting for urine creatinine, specific gravity, electrical conductivity, or potassium improved the precision of the estimation. Correcting for specific gravity using the following formula gave the most precise estimate (average error rate = 16.9%): [blood 137 Cs] = [urinary 137 Cs]/([specific gravity] - 1)/329. Urine samples are faster to measure than blood samples because urine can be obtained in larger quantities and has a higher 137 Cs concentration than blood. These advantages of urine and the estimation precision demonstrated in our study, indicate that estimation of blood 137 Cs using urine samples is a practical means of monitoring radioactive contamination in live cattle. © 2017 Japanese Society of Animal Science.

  17. An econometric method for estimating population parameters from non-random samples: An application to clinical case finding.

    Science.gov (United States)

    Burger, Rulof P; McLaren, Zoë M

    2017-09-01

    The problem of sample selection complicates the process of drawing inference about populations. Selective sampling arises in many real world situations when agents such as doctors and customs officials search for targets with high values of a characteristic. We propose a new method for estimating population characteristics from these types of selected samples. We develop a model that captures key features of the agent's sampling decision. We use a generalized method of moments with instrumental variables and maximum likelihood to estimate the population prevalence of the characteristic of interest and the agents' accuracy in identifying targets. We apply this method to tuberculosis (TB), which is the leading infectious disease cause of death worldwide. We use a national database of TB test data from South Africa to examine testing for multidrug resistant TB (MDR-TB). Approximately one quarter of MDR-TB cases was undiagnosed between 2004 and 2010. The official estimate of 2.5% is therefore too low, and MDR-TB prevalence is as high as 3.5%. Signal-to-noise ratios are estimated to be between 0.5 and 1. Our approach is widely applicable because of the availability of routinely collected data and abundance of potential instruments. Using routinely collected data to monitor population prevalence can guide evidence-based policy making. Copyright © 2017 John Wiley & Sons, Ltd.

  18. Improving the collection of knowledge, attitude and practice data with community surveys: a comparison of two second-stage sampling methods.

    Science.gov (United States)

    Davis, Rosemary H; Valadez, Joseph J

    2014-12-01

    Second-stage sampling techniques, including spatial segmentation, are widely used in community health surveys when reliable household sampling frames are not available. In India, an unresearched technique for household selection is used in eight states, which samples the house with the last marriage or birth as the starting point. Users question whether this last-birth or last-marriage (LBLM) approach introduces bias affecting survey results. We conducted two simultaneous population-based surveys. One used segmentation sampling; the other used LBLM. LBLM sampling required modification before assessment was possible and a more systematic approach was tested using last birth only. We compared coverage proportions produced by the two independent samples for six malaria indicators and demographic variables (education, wealth and caste). We then measured the level of agreement between the caste of the selected participant and the caste of the health worker making the selection. No significant difference between methods was found for the point estimates of six malaria indicators, education, caste or wealth of the survey participants (range of P: 0.06 to >0.99). A poor level of agreement occurred between the caste of the health worker used in household selection and the caste of the final participant, (Κ = 0.185), revealing little association between the two, and thereby indicating that caste was not a source of bias. Although LBLM was not testable, a systematic last-birth approach was tested. If documented concerns of last-birth sampling are addressed, this new method could offer an acceptable alternative to segmentation in India. However, inter-state caste variation could affect this result. Therefore, additional assessment of last birth is required before wider implementation is recommended. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine © The Author 2013; all rights reserved.

  19. Failure Probability Calculation Method Using Kriging Metamodel-based Importance Sampling Method

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seunggyu [Korea Aerospace Research Institue, Daejeon (Korea, Republic of); Kim, Jae Hoon [Chungnam Nat’l Univ., Daejeon (Korea, Republic of)

    2017-05-15

    The kernel density was determined based on sampling points obtained in a Markov chain simulation and was assumed to be an important sampling function. A Kriging metamodel was constructed in more detail in the vicinity of a limit state. The failure probability was calculated based on importance sampling, which was performed for the Kriging metamodel. A pre-existing method was modified to obtain more sampling points for a kernel density in the vicinity of a limit state. A stable numerical method was proposed to find a parameter of the kernel density. To assess the completeness of the Kriging metamodel, the possibility of changes in the calculated failure probability due to the uncertainty of the Kriging metamodel was calculated.

  20. Geometry of the self-consistent collective-coordinate method for the large-amplitude collective motion

    International Nuclear Information System (INIS)

    Sakata, Fumihiko; Marumori, Toshio; Hashimoto, Yukio; Une, Tsutomu.

    1983-05-01

    The geometry of the self-consistent collective-coordinate (SCC) method formulated within the framework of the time-dependent Hartree-Fock (TDHF) theory is investigated by associating the variational parameters with a symplectic manifold (a TDHF manifold). With the use of a canonical-variables parametrization, it is shown that the TDHF equation is equivalent to the canonical equations of motion in classical mechanics in the TDHF manifold. This enables us to investigate geometrical structure of the SCC method in the language of the classical mechanics. The SCC method turns out to give a prescription how to dynamically extract a ''maximally-decoupled'' collective submanifold (hypersurface) out of the TDHF manifold, in such a way that a certain kind of trajectories corresponding to the large-amplitude collective motion under consideration can be reproduced on the hypersurface as precisely as possible. The stability of the hypersurface at each point on it is investigated, in order to see whether the hypersurface obtained by the SCC method is really an approximate integral surface in the TDHF manifold or not. (author)

  1. Comparison of noninvasive sample collection procedures for canine leishmaniasis diagnosis by PCR-hybridization

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Sidney de Almeida; Andrade, Antero Silva Ribeiro de [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)]. E-mail: vidasnino@yahoo.com.br; antero@cdtn.br; Ituassu, Leonardo Trindade; Melo, Maria Norma de [Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil)]. E-mail: melo@mono.icb.ufmg.br; ltituassu@yahoo.com.br

    2007-07-01

    The dogs are the main reservoir of the visceral leishmaniasis etiological agent Leishmania chagasi and these animals have to be systematically monitored. The aim of present work was to standardize a method for canine leishmaniasis diagnosis using DNA samples obtained by a noninvasive ways. Two kind of samples were compared: conjunctival swab and blood. The samples were analyzed by the Polymerase Chain Reaction (PCR) associated with the hybridization of {sup 32}P labeled DNA probes. An in vitro test was carried out using cotton swabs seeded with L. chagasi parasites at different cell numbers. After that, the PCR and hybridization sensitivity was evaluated in two groups of 23 seropositive dogs. Conjunctival swabs and 1,0 mL of blood were collected from each animal. 90 {mu}L of these blood were spotted onto filter paper and the remaining used to prepare the buffy coat. The DNA purification from cotton swabs was carried out through the phenol-chloroform (group 1) or boiling (group 2). The Wizard kit was used to DNA extraction from buffy coat. The filters were treated according to Dialab protocol. The analysis of the seeded samples showed that the PCR was able to identify until ten parasites while the following hybridization of the PCR products allows the detection of until one parasite. The PCR positivity for the conjunctival swabs were 73.9% and 52.2% respectively to the groups 1 and 2. For buffy coat the positivities were 43.5% and 56.5% respectively. The filters presented the lowest positivity. The hybridization step was not accomplished yet for these samples. (author)

  2. β-trace protein as a diagnostic marker for perilymphatic fluid fistula: a prospective controlled pilot study to test a sample collection technique.

    Science.gov (United States)

    Bachmann-Harildstad, Gregor; Stenklev, Niels Christian; Myrvoll, Elin; Jablonski, Greg; Klingenberg, Olav

    2011-01-01

    The diagnosis of perilymphatic fluid (PLF) fistula is still challenging. Perilymphatic fluid fistula is one possible complication after stapedotomy or cochlear implant surgery. We have performed a prospective diagnostic pilot study to further investigate β-trace protein (β-TP) as a marker for PLF fistula. In this pilot study, we tested the sensitivity of the β-TP marker using a simple method for sample collection from the tympanic cavity. Prospective controlled diagnostic study. Two-center tertiary referral hospitals. A total of 35 adult patients undergoing ear surgery were included. Subjects were divided into 2 groups: 1) 19 patients undergoing stapedotomy were investigated for PLF fistula in samples obtained from the tympanic cavity and 2) 16 patients undergoing myringoplasty were investigated for PLF fistula in samples from the tympanic cavity. This group served as the control. Mean age +/- SD at surgery was 49.9 +/- 8.0 years in the study group and 39.69 +/- 15.47 years in the control group. β-Trace protein (prostaglandin D synthase) in tympanic cavity samples and serum samples was analyzed. The samples were collected by gradually filling the tympanic cavity with 100 to 200 μl sodium chloride and by immediately collecting a volume of 60 to 100 μl in a mucus specimen set container. The concentration of β-TP was quantified using laser nephelometry. The median β-TP in the study group was 0.8 mg/L (range, 0.05-4.5 mg/L). In the control group, the median β-TP value was 0.16 mg/L (range, 0.01-0.36 mg/L). Thirty-five percent of the values in the study group were below the highest value in the negative control group. The β-TP values of the tympanic cavity samples were significantly higher in the study group than in controls (p = 0.0001). The serum values were 0.55 +/- 0.18 and 0.53 +/- 0.11 mg/L, respectively. It may be feasible to test for PLF fistula using β-TP in samples from the tympanic cavity. Our results, however, suggest a relative low diagnostic

  3. Geochemical Data for Samples Collected in 2007 Near the Concealed Pebble Porphyry Cu-Au-Mo Deposit, Southwest Alaska

    Science.gov (United States)

    Fey, David L.; Granitto, Matthew; Giles, Stuart A.; Smith, Steven M.; Eppinger, Robert G.; Kelley, Karen D.

    2008-01-01

    In the summer of 2007, the U.S. Geological Survey (USGS) began an exploration geochemical research study over the Pebble porphyry copper-gold-molydenum (Cu-Au-Mo) deposit in southwest Alaska. The Pebble deposit is extremely large and is almost entirely concealed by tundra, glacial deposits, and post-Cretaceous volcanic and volcaniclastic rocks. The deposit is presently being explored by Northern Dynasty Minerals, Ltd., and Anglo-American LLC. The USGS undertakes unbiased, broad-scale mineral resource assessments of government lands to provide Congress and citizens with information on national mineral endowment. Research on known deposits is also done to refine and better constrain methods and deposit models for the mineral resource assessments. The Pebble deposit was chosen for this study because it is concealed by surficial cover rocks, it is relatively undisturbed (except for exploration company drill holes), it is a large mineral system, and it is fairly well constrained at depth by the drill hole geology and geochemistry. The goals of the USGS study are (1) to determine whether the concealed deposit can be detected with surface samples, (2) to better understand the processes of metal migration from the deposit to the surface, and (3) to test and develop methods for assessing mineral resources in similar concealed terrains. This report presents analytical results for geochemical samples collected in 2007 from the Pebble deposit and surrounding environs. The analytical data are presented digitally both as an integrated Microsoft 2003 Access? database and as Microsoft 2003 Excel? files. The Pebble deposit is located in southwestern Alaska on state lands about 30 km (18 mi) northwest of the village of Illiamna and 320 km (200 mi) southwest of Anchorage (fig. 1). Elevations in the Pebble area range from 287 m (940 ft) at Frying Pan Lake just south of the deposit to 1146 m (3760 ft) on Kaskanak Mountain about 5 km (5 mi) to the west. The deposit is in an area of

  4. Chlamydia trachomatis antibody detection in home-collected blood samples for use in epidemiological studies.

    NARCIS (Netherlands)

    Hoenderboom, B M; van Ess, E F; van den Broek, I V F; van Loo, I H M; Hoebe, C J P A; Ouburg, S; Morré, S A

    Capillary blood collected in serum tubes was subjected to centrifugation delay while stored at room temperature. Chlamydia trachomatis (CT) IgG concentrations in aliquoted serum of these blood samples remained stable for seven days after collection. CT IgG concentrations can reliably be measured in

  5. Improved explosive collection and detection with rationally assembled surface sampling materials

    Energy Technology Data Exchange (ETDEWEB)

    Chouyyok, Wilaiwan; Bays, J. Timothy; Gerasimenko, Aleksandr A.; Cinson, Anthony D.; Ewing, Robert G.; Atkinson, David A.; Addleman, R. Shane

    2016-01-01

    Sampling and detection of trace explosives is a key analytical process in modern transportation safety. In this work we have explored some of the fundamental analytical processes for collection and detection of trace level explosive on surfaces with the most widely utilized system, thermal desorption IMS. The performance of the standard muslin swipe material was compared with chemically modified fiberglass cloth. The fiberglass surface was modified to include phenyl functional groups. When compared to standard muslin, the phenyl functionalized fiberglass sampling material showed better analyte release from the sampling material as well as improved response and repeatability from multiple uses of the same swipe. The improved sample release of the functionalized fiberglass swipes resulted in a significant increase in sensitivity. Various physical and chemical properties were systematically explored to determine optimal performance. The results herein have relevance to improving the detection of other explosive compounds and potentially to a wide range of other chemical sampling and field detection challenges.

  6. 77 FR 17493 - Agency Information Collection Activities: Proposed Collection; Comment Request; DOI Generic...

    Science.gov (United States)

    2012-03-26

    ... justify the proposed sample size, the expected response rate, methods for assessing potential non...: Proposed Collection; Comment Request; DOI Generic Clearance for the Collection of Qualitative Feedback on... (Generic ICR): ``DOI Generic Clearance for the Collection of Qualitative Feedback on Agency Service...

  7. 75 FR 80542 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2010-12-22

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  8. 76 FR 12140 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-03-04

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  9. 76 FR 17861 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-03-31

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  10. 76 FR 41280 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-07-13

    ... proposed sample size, the expected response rate, methods for assessing potential non-response bias, the... Activities: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...

  11. 76 FR 61360 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-10-04

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential... Activities: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative... Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under the Paperwork...

  12. Evaluation of human papillomavirus detection by Abbott m2000 system on samples collected by FTA Elute™ Card in a Chinese HIV-1 positive population.

    Science.gov (United States)

    Qin, Yu; Zhang, Hongyun; Marlowe, Natalia; Fei, Mandong; Yu, Judy; Lei, Xiaoqin; Yu, Lulu; Zhang, Jia; Cao, Di; Ma, Li; Chen, Wen

    2016-12-01

    HIV+/AIDS women have an increased risk of developing into CIN and cervical cancer compared to the general population. Limited medical resource and the lack of AIDS relevant knowledge impair the coverage and efficiency of cervical cancer screening. To compare the clinical performance of self-collected dry storage medium (FTA Elute card) and physician-collected PreservCyt medium in detection of high risk human papillomavirus (HR HPV) among HIV-1 positive population. Three hundred HIV-1 positive women (aged 25-65) were recruited from Yunnan infectious hospital. Two cervicovaginal samples were collected from each participant: one was collected by the women themselves and applied on a FTA Elute card; the other one was collected by a physician and stored in PreservCyt solution. All the samples were tested for 14 HR HPV using Abbott RealTime High Risk HPV assay. Biopsies were taken for histological diagnosis if any abnormal impression was noticed under colposcopy. 291 (97.0%) of participants were eligible for this study. 101 (34.70%) participants were found HR HPV positive in both FTA card and PreservCyt samples, and 19 (6.53%) women were diagnosed as CIN2+. The HR HPV positive rate on samples collected by FTA Elute card and PreservCyt solution was 42.61% and 39.86%, respectively. The overall agreement was 87% (kappa=0.731) between FTA card and PreservCyt. The clinical sensitivity and specificity of FTA card and PreservCyt were 100%, 61.39% and 100%, 64.33%, respectively. In this study, FTA Elute card demonstrated a good performance on self-collected sample for HR HPV detection in HIV-1 positive population. For the women from low-resource area with HIV-1 infection, FTA Elute card could be an attractive sample collection method for cervical cancer screening. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Mixed Methods Sampling: A Typology with Examples

    Science.gov (United States)

    Teddlie, Charles; Yu, Fen

    2007-01-01

    This article presents a discussion of mixed methods (MM) sampling techniques. MM sampling involves combining well-established qualitative and quantitative techniques in creative ways to answer research questions posed by MM research designs. Several issues germane to MM sampling are presented including the differences between probability and…

  14. An Interdisciplinary Method for the Visualization of Novel High-Resolution Precision Photography and Micro-XCT Data Sets of NASA's Apollo Lunar Samples and Antarctic Meteorite Samples to Create Combined Research-Grade 3D Virtual Samples for the Benefit of Astromaterials Collections Conservation, Curation, Scientific Research and Education

    Science.gov (United States)

    Blumenfeld, E. H.; Evans, C. A.; Oshel, E. R.; Liddle, D. A.; Beaulieu, K.; Zeigler, R. A.; Hanna, R. D.; Ketcham, R. A.

    2016-01-01

    New technologies make possible the advancement of documentation and visualization practices that can enhance conservation and curation protocols for NASA's Astromaterials Collections. With increasing demands for accessibility to updated comprehensive data, and with new sample return missions on the horizon, it is of primary importance to develop new standards for contemporary documentation and visualization methodologies. Our interdisciplinary team has expertise in the fields of heritage conservation practices, professional photography, photogrammetry, imaging science, application engineering, data curation, geoscience, and astromaterials curation. Our objective is to create virtual 3D reconstructions of Apollo Lunar and Antarctic Meteorite samples that are a fusion of two state-of-the-art data sets: the interior view of the sample by collecting Micro-XCT data and the exterior view of the sample by collecting high-resolution precision photography data. These new data provide researchers an information-rich visualization of both compositional and textural information prior to any physical sub-sampling. Since January 2013 we have developed a process that resulted in the successful creation of the first image-based 3D reconstruction of an Apollo Lunar Sample correlated to a 3D reconstruction of the same sample's Micro- XCT data, illustrating that this technique is both operationally possible and functionally beneficial. In May of 2016 we began a 3-year research period during which we aim to produce Virtual Astromaterials Samples for 60 high-priority Apollo Lunar and Antarctic Meteorite samples and serve them on NASA's Astromaterials Acquisition and Curation website. Our research demonstrates that research-grade Virtual Astromaterials Samples are beneficial in preserving for posterity a precise 3D reconstruction of the sample prior to sub-sampling, which greatly improves documentation practices, provides unique and novel visualization of the sample's interior and

  15. Log sampling methods and software for stand and landscape analyses.

    Science.gov (United States)

    Lisa J. Bate; Torolf R. Torgersen; Michael J. Wisdom; Edward O. Garton; Shawn C. Clabough

    2008-01-01

    We describe methods for efficient, accurate sampling of logs at landscape and stand scales to estimate density, total length, cover, volume, and weight. Our methods focus on optimizing the sampling effort by choosing an appropriate sampling method and transect length for specific forest conditions and objectives. Sampling methods include the line-intersect method and...

  16. Disposable collection kit for rapid and reliable collection of saliva.

    Science.gov (United States)

    Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek

    2015-01-01

    To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 μl) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method on subsequent immunoassay results was verified by assessing salivary cortisol levels in the samples and comparing them to controls. The recovered volumes for the whole saliva samples were 3.85 ± 0.28, 10.79 ± 0.95, and 31.18 ± 1.72 μl, respectively (CV = 8.76%) and 2.91 ± 0.19, 9.75 ± 0.43, and 29.64 ± 0.91 μl, respectively, (CV = 6.36%) for the controls. There was a close correspondence between the salivary cortisol levels from the saliva samples obtained by the collection kit and the controls (R(2)  > 0.96). The disposable saliva collection kit allows accurate and repeatable collection of fixed amounts of whole saliva and does not interfere with subsequent measurements of salivary cortisol. The simple collection process, lack of elaborate specimen recovery steps, and the short turnaround time (<3 min) should render the kit attractive to test subjects and researchers alike. © 2015 Wiley Periodicals, Inc.

  17. 21 CFR 809.40 - Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs...

    Science.gov (United States)

    2010-04-01

    ... OTC test sample collection systems for drugs of abuse testing. 809.40 Section 809.40 Food and Drugs... Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs of abuse testing. (a) Over-the-counter (OTC) test sample collection systems for drugs of abuse testing (§ 864.3260...

  18. Normalisation of spot urine samples to 24-h collection for assessment of exposure to uranium

    International Nuclear Information System (INIS)

    Marco, R.; Katorza, E.; Gonen, R.; German, U.; Tshuva, A.; Pelled, O.; Paz-tal, O.; Adout, A.; Karpas, Z.

    2008-01-01

    For dose assessment of workers at Nuclear Research Center Negev exposed to natural uranium, spot urine samples are analysed and the results are normalised to 24-h urine excretion based on 'standard' man urine volume of 1.6 l d -1 . In the present work, the urine volume, uranium level and creatinine concentration were determined in two or three 24-h urine collections from 133 male workers (319 samples) and 33 female workers (88 samples). Three volunteers provided urine spot samples from each voiding during a 24-h period and a good correlation was found between the relative level of creatinine and uranium in spot samples collected from the same individual. The results show that normalisation of uranium concentration to creatinine in a spot sample represents the 24-h content of uranium better than normalisation to the standard volume and may be used to reduce the uncertainty of dose assessment based on spot samples. (authors)

  19. New methods for sampling sparse populations

    Science.gov (United States)

    Anna Ringvall

    2007-01-01

    To improve surveys of sparse objects, methods that use auxiliary information have been suggested. Guided transect sampling uses prior information, e.g., from aerial photographs, for the layout of survey strips. Instead of being laid out straight, the strips will wind between potentially more interesting areas. 3P sampling (probability proportional to prediction) uses...

  20. Assessing representativeness of sampling methods for reaching men who have sex with men: a direct comparison of results obtained from convenience and probability samples.

    Science.gov (United States)

    Schwarcz, Sandra; Spindler, Hilary; Scheer, Susan; Valleroy, Linda; Lansky, Amy

    2007-07-01

    Convenience samples are used to determine HIV-related behaviors among men who have sex with men (MSM) without measuring the extent to which the results are representative of the broader MSM population. We compared results from a cross-sectional survey of MSM recruited from gay bars between June and October 2001 to a random digit dial telephone survey conducted between June 2002 and January 2003. The men in the probability sample were older, better educated, and had higher incomes than men in the convenience sample, the convenience sample enrolled more employed men and men of color. Substance use around the time of sex was higher in the convenience sample but other sexual behaviors were similar. HIV testing was common among men in both samples. Periodic validation, through comparison of data collected by different sampling methods, may be useful when relying on survey data for program and policy development.

  1. Statistical sampling method for releasing decontaminated vehicles

    International Nuclear Information System (INIS)

    Lively, J.W.; Ware, J.A.

    1996-01-01

    Earth moving vehicles (e.g., dump trucks, belly dumps) commonly haul radiologically contaminated materials from a site being remediated to a disposal site. Traditionally, each vehicle must be surveyed before being released. The logistical difficulties of implementing the traditional approach on a large scale demand that an alternative be devised. A statistical method (MIL-STD-105E, open-quotes Sampling Procedures and Tables for Inspection by Attributesclose quotes) for assessing product quality from a continuous process was adapted to the vehicle decontamination process. This method produced a sampling scheme that automatically compensates and accommodates fluctuating batch sizes and changing conditions without the need to modify or rectify the sampling scheme in the field. Vehicles are randomly selected (sampled) upon completion of the decontamination process to be surveyed for residual radioactive surface contamination. The frequency of sampling is based on the expected number of vehicles passing through the decontamination process in a given period and the confidence level desired. This process has been successfully used for 1 year at the former uranium mill site in Monticello, Utah (a CERCLA regulated clean-up site). The method forces improvement in the quality of the decontamination process and results in a lower likelihood that vehicles exceeding the surface contamination standards are offered for survey. Implementation of this statistical sampling method on Monticello Projects has resulted in more efficient processing of vehicles through decontamination and radiological release, saved hundreds of hours of processing time, provided a high level of confidence that release limits are met, and improved the radiological cleanliness of vehicles leaving the controlled site

  2. 19 CFR 151.70 - Method of sampling by Customs.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Method of sampling by Customs. 151.70 Section 151... THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.70 Method of sampling by Customs. A general sample shall be taken from each sampling unit, unless it is not...

  3. an assessment of methods for sampling carabid beetles

    African Journals Online (AJOL)

    Mgina

    collection of epigaeic (ground-dwelling) invertebrates (Southwood and Henderson,. 2000). It has been widely used for sampling carabid beetles in biodiversity inventories. (Niemela et al. 1994, Davies 2000, Nyundo. 2002), population and community ecology. (Greenslade 1968, Refseth, 1980,. Niemela1988, Niemela et al.

  4. Planning Considerations Related to Collecting and Analyzing Samples of the Martian Soils

    Science.gov (United States)

    Liu, Yang; Mellon, Mike T.; Ming, Douglas W.; Morris, Richard V.; Noble, Sarah K.; Sullivan, Robert J.; Taylor, Lawrence A.; Beaty, David W.

    2014-01-01

    The Mars Sample Return (MSR) End-to-End International Science Analysis Group (E2E-iSAG [1]) established scientific objectives associ-ated with Mars returned-sample science that require the return and investigation of one or more soil samples. Soil is defined here as loose, unconsolidated materials with no implication for the presence or absence of or-ganic components. The proposed Mars 2020 (M-2020) rover is likely to collect and cache soil in addition to rock samples [2], which could be followed by future sample retrieval and return missions. Here we discuss key scientific consid-erations for sampling and caching soil samples on the proposed M-2020 rover, as well as the state in which samples would need to be preserved when received by analysts on Earth. We are seeking feedback on these draft plans as input to mission requirement formulation. A related planning exercise on rocks is reported in an accompanying abstract [3].

  5. Reduced detection by Ziehl-Neelsen method of acid-fast bacilli in sputum samples preserved in cetylpyridinium chloride solution.

    Science.gov (United States)

    Selvakumar, N; Sudhamathi, S; Duraipandian, M; Frieden, T R; Narayanan, P R

    2004-02-01

    Twelve health facilities implementing the DOTS strategy, and the Tuberculosis Research Centre (TRC), Chennai, India. To determine the detection rates using Ziehl-Neelsen (ZN) and auramine-phenol to stain acid-fast bacilli (AFB) in sputum samples stored in cetylpyridinium chloride (CPC) solution. Two smears were prepared from each of 988 sputum samples collected in CPC and randomly allocated, one to ZN and the other to auramine-phenol staining. All samples were processed for culture of Mycobacterium tuberculosis. A significantly higher proportion of samples were negative using the ZN method compared to the auramine-phenol method (74.5% vs. 61.8%, McNamara's paired chi2 test; P < 0.001). Among 377 samples that were positive using auramine-phenol, 44% were negative using ZN. There were more culture-positive, smear-negative samples in ZN (52.7%) than in auramine-phenol (30%); the difference attained statistical significance (McNemar's paired chi2 test; P < 0.00004). Using ZN, of the 104 smears made immediately after collection, 52 were positive for AFB, of which only 35 (67.3%) were positive after storage in CPC; the reduction in the number of positive smears attained statistical significance (McNemar's paired chi2 test; P = 0.004). Detection of AFB in sputum samples preserved in CPC is significantly reduced using ZN staining.

  6. Collecting data from migrants in Ghana: Lessons learned using respondent-driven sampling

    Directory of Open Access Journals (Sweden)

    Samantha R. Lattof

    2018-03-01

    Full Text Available Background: Policymakers and program implementers require high-quality data on migrants and migration in low- and middle-income countries (LMIC; however, a shortage of high-quality data exists in these settings. Sampling migrant populations requires better techniques. Respondent-driven sampling (RDS may be one such solution. Objective: Using Ghana as a case study, the objectives of this paper are to: 1 assess RDS recruitment productivity, network size, and ties of internal migrants; 2 test for homophily; and 3 detail the successes of and challenges to implementing RDS in Ghana and how these lessons can be applied to migrant populations in other LMIC settings. Methods: This study used RDS to sample 625 rural-urban female migrants working as market porters (kayayei in Accra, Ghana. Results: This study generated the most comprehensive data set on kayayei to date. Network size increases as participants become more educated and migrate more often to Accra. Ethnic group membership is an important determinant of recruitment, with certain groups preferring to recruit from within. Employing members of the kayayei population to collect data built crucial trust. Conclusions: Whilst RDS is not a one-size-fits-all solution for sampling hard-to-reach migrants in LMIC, it can be a powerful tool to uncover and to recruit hard-to-reach migrant populations. In countries with multiple ethnolinguistic groups, recruiting a migrant population with greater ethnolinguistic overlap may facilitate quicker equilibrium. Contribution: This study expands the evidence base on use of RDS among migrant populations in LMIC and provides lessons learned to assist other researchers implementing RDS in LMIC settings.

  7. Innovative methods for inorganic sample preparation

    Energy Technology Data Exchange (ETDEWEB)

    Essling, A.M.; Huff, E.A.; Graczyk, D.G.

    1992-04-01

    Procedures and guidelines are given for the dissolution of a variety of selected materials using fusion, microwave, and Parr bomb techniques. These materials include germanium glass, corium-concrete mixtures, and zeolites. Emphasis is placed on sample-preparation approaches that produce a single master solution suitable for complete multielement characterization of the sample. In addition, data are presented on the soil microwave digestion method approved by the Environmental Protection Agency (EPA). Advantages and disadvantages of each sample-preparation technique are summarized.

  8. Innovative methods for inorganic sample preparation

    International Nuclear Information System (INIS)

    Essling, A.M.; Huff, E.A.; Graczyk, D.G.

    1992-04-01

    Procedures and guidelines are given for the dissolution of a variety of selected materials using fusion, microwave, and Parr bomb techniques. These materials include germanium glass, corium-concrete mixtures, and zeolites. Emphasis is placed on sample-preparation approaches that produce a single master solution suitable for complete multielement characterization of the sample. In addition, data are presented on the soil microwave digestion method approved by the Environmental Protection Agency (EPA). Advantages and disadvantages of each sample-preparation technique are summarized

  9. Cadmium and lead determination by ICPMS: Method optimization and application in carabao milk samples

    Directory of Open Access Journals (Sweden)

    Riza A. Magbitang

    2012-06-01

    Full Text Available A method utilizing inductively coupled plasma mass spectrometry (ICPMS as the element-selective detector with microwave-assisted nitric acid digestion as the sample pre-treatment technique was developed for the simultaneous determination of cadmium (Cd and lead (Pb in milk samples. The estimated detection limits were 0.09ìg kg-1 and 0.33ìg kg-1 for Cd and Pb, respectively. The method was linear in the concentration range 0.01 to 500ìg kg-1with correlation coefficients of 0.999 for both analytes.The method was validated using certified reference material BCR 150 and the determined values for Cd and Pb were 18.24 ± 0.18 ìg kg-1 and 807.57 ± 7.07ìg kg-1, respectively. Further validation using another certified reference material, NIST 1643e, resulted in determined concentrations of 6.48 ± 0.10 ìg L-1 for Cd and 21.96 ± 0.87 ìg L-1 for Pb. These determined values agree well with the certified values in the reference materials.The method was applied to processed and raw carabao milk samples collected in Nueva Ecija, Philippines.The Cd levels determined in the samples were in the range 0.11 ± 0.07 to 5.17 ± 0.13 ìg kg-1 for the processed milk samples, and 0.11 ± 0.07 to 0.45 ± 0.09 ìg kg-1 for the raw milk samples. The concentrations of Pb were in the range 0.49 ± 0.21 to 5.82 ± 0.17 ìg kg-1 for the processed milk samples, and 0.72 ± 0.18 to 6.79 ± 0.20 ìg kg-1 for the raw milk samples.

  10. 76 FR 63301 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-10-12

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under...

  11. Piloting a Non-Invasive Genetic Sampling Method for Evaluating Population-Level Benefits of Wildlife Crossing Structures

    Directory of Open Access Journals (Sweden)

    Anthony P. Clevenger

    2010-03-01

    Full Text Available Intuitively, wildlife crossing structures should enhance the viability of wildlife populations. Previous research has demonstrated that a broad range of species will use crossing structures, however, questions remain as to whether these measures actually provide benefits to populations. To assess this, studies will need to determine the number of individuals using crossings, their sex, and their genetic relationships. Obtaining empirical data demonstrating population-level benefits for some species can be problematic and challenging at best. Molecular techniques now make it possible to identify species, individuals, their sex, and their genetic relatedness from hair samples collected through non-invasive genetic sampling (NGS. We describe efforts to pilot a method to assess potential population-level benefits of wildlife crossing structures. We tested the feasibility of a prototype NGS system designed to sample hair from black bears (Ursus americanus and grizzly bears (U. arctos at two wildlife underpasses. The piloted hair-sampling method did not deter animal use of the trial underpasses and was effective at sampling hair from more than 90% of the bear crossing events at the underpasses. Hair samples were also obtained from non-target carnivore species, including three out of five (60% cougar (Puma concolor crossing events. Individual identification analysis revealed that three female and two male grizzly bears used one wildlife underpass, whereas two female and three male black bears were identified as using the other underpass. Of the 36 hair samples from bears analyzed, five failed, resulting in an 87% extraction success rate, and six more were only identified to species. Overall, 70% of the hair samples from bears collected in the field had sufficient DNA for extraction purposes. Preliminary data from our NGS suggest the technique can be a reliable method to assess the population-level benefits of Banff wildlife crossings. Furthermore, NGS

  12. PIXE Analysis of Atmospheric Aerosol Samples Collected in the Adirondack Mountains

    Science.gov (United States)

    Yoskowitz, Josh; Ali, Salina; Nadareski, Benjamin; Safiq, Alexandrea; Smith, Jeremy; Labrake, Scott; Vineyard, Michael

    2013-10-01

    We have performed an elemental analysis of atmospheric aerosol samples collected at Piseco Lake in Upstate New York using proton induced x-ray emission spectroscopy (PIXE). This work is part of a systematic study of airborne pollution in the Adirondack Mountains. Of particular interest is the sulfur content that can contribute to acid rain, a well-documented problem in the Adirondacks. We used a nine-stage cascade impactor to collect the samples and distribute the particulate matter onto Kapton foils by particle size. The PIXE experiments were performed with 2.2-MeV proton beams from the 1.1-MV pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. X-Ray energy spectra were measured with a silicon drift detector and analyzed with GUPIX software to determine the elemental concentrations of the aerosols. A broad range of elements from silicon to zinc were detected with significant sulfur concentrations measured for particulate matter between 0.25 and 0.5 μm in size. The PIXE analysis will be described and preliminary results will be presented.

  13. Sedimentary characteristics of samples collected from some submarine canyons

    NARCIS (Netherlands)

    Bouma, Arnold H.

    Oriented rectangular cores of 20.3 × 30.5 cm and 45.7 cm high have been collected in a number of submarine canyons off southern California (U.S.A.) and off the southern tip of Baja California (Mexico) for a detailed study of their sedimentary structures. By applying several methods, mainly X-ray

  14. Determination of gold of No. 501 uranium deposits and soil samples by cold leaching gold in dilute aqua regia and collection on activated charcoal

    International Nuclear Information System (INIS)

    Shen Maogen; Yao Liying.

    1989-01-01

    The gold determination method is described by cold leaching gold in dilute aqua regia and collection on activated charcoal and presents the results obtained in determining gold of uranium deposits and soil samples

  15. Evaluation of field sampling and preservation methods for strontium-90 in ground water at the Idaho National Engineering Laboratory, Idaho

    International Nuclear Information System (INIS)

    Cecil, L.D.; Knobel, L.L.; Wegner, S.J.; Moore, L.L.

    1989-01-01

    Water from four wells completed in the Snake River Plain aquifer was sampled as part of the US Geological Survey's quality assurance program to evaluate the effect of filtration and preservation methods on strontium-90 concentrations in groundwater at the Idaho National Engineering Laboratory. Water from each well was filtered through either a 0.45-micrometer membrane or a 0.1-micrometer membrane filter; unfiltered samples also were collected. Two sets of filtered and two sets of unfiltered samples was preserved in the field with reagent-grade hydrochloric acid and the other set of samples was not acidified. For water from wells with strontium-90 concentrations at or above the reporting level, 94% or more of the strontium-90 is in true solution or in colloidal particles smaller than 0.1 micrometer. These results suggest that within-laboratory reproducibility for strontium-90 in groundwater at the INEL is not significantly affected by changes in filtration and preservation methods used for sample collections. 13 refs., 2 figs., 6 tabs

  16. Direct PCR amplification of DNA from human bloodstains, saliva, and touch samples collected with microFLOQ® swabs.

    Science.gov (United States)

    Ambers, Angie; Wiley, Rachel; Novroski, Nicole; Budowle, Bruce

    2018-01-01

    Previous studies have shown that nylon flocked swabs outperform traditional fiber swabs in DNA recovery due to their innovative design and lack of internal absorbent core to entrap cellular materials. The microFLOQ ® Direct swab, a miniaturized version of the 4N6 FLOQSwab ® , has a small swab head that is treated with a lysing agent which allows for direct amplification and DNA profiling from sample collection to final result in less than two hours. Additionally, the microFLOQ ® system subsamples only a minute portion of a stain and preserves the vast majority of the sample for subsequent testing or re-analysis, if desired. The efficacy of direct amplification of DNA from dilute bloodstains, saliva stains, and touch samples was evaluated using microFLOQ ® Direct swabs and the GlobalFiler™ Express system. Comparisons were made to traditional methods to assess the robustness of this alternate workflow. Controlled studies with 1:19 and 1:99 dilutions of bloodstains and saliva stains consistently yielded higher STR peak heights than standard methods with 1ng input DNA from the same samples. Touch samples from common items yielded single source and mixed profiles that were consistent with primary users of the objects. With this novel methodology/workflow, no sample loss occurs and therefore more template DNA is available during amplification. This approach may have important implications for analysis of low quantity and/or degraded samples that plague forensic casework. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  17. Evaluation of subsurface exploration, sampling, and water-quality-analysis methods at an abandoned wood-preserving plant site at Jackson, Tennessee

    Science.gov (United States)

    Parks, W.S.; Carmichael, J.K.; Mirecki, J.E.

    1993-01-01

    Direct Push Technology (DPT) and a modified-auger method of sampling were used at an abandoned wood-preserving plant site at Jackson, Tennessee, to collect lithologic data and ground-water samples in an area known to be affected by a subsurface creosote plume. The groundwater samples were analyzed using (1) gas chromatography with photo-ionization detection (GS/PID), (2) high- performance liquid chromatography (HPLC), (3) colonmetric phenol analysis, and (4) toxicity bioassay. DPT piezocone and cone-penetrometer-type tools provided lithologic data and ground-water samples at two onsite stations to a depth of refusal of about 35 feet below land surface. With the assistance of an auger rig, this depth was extended to about 65 feet by pushing the tools in advance of the augers. Following the DPT work, a modified-auger method was tested by the USGS. This method left doubt as to the integrity of the samples collected once zones of contamination were penetrated. GC/PID and HPLC methods of water-quality analysis provided the most data concerning contaminants in the ground-water and proved to be the most effective in creosote plume detection. Analyses from these methods showed that the highest concentrations of contaminants were detected at depths less than about 35 feet below land surface. Phenol analyses provided data supplemental to the HPLC analyses. Bioassay data indicated that toxicity associated with the plume extended to depths of about 55 feet below land surface.

  18. Sampling methods for low-frequency electromagnetic imaging

    International Nuclear Information System (INIS)

    Gebauer, Bastian; Hanke, Martin; Schneider, Christoph

    2008-01-01

    For the detection of hidden objects by low-frequency electromagnetic imaging the linear sampling method works remarkably well despite the fact that the rigorous mathematical justification is still incomplete. In this work, we give an explanation for this good performance by showing that in the low-frequency limit the measurement operator fulfils the assumptions for the fully justified variant of the linear sampling method, the so-called factorization method. We also show how the method has to be modified in the physically relevant case of electromagnetic imaging with divergence-free currents. We present numerical results to illustrate our findings, and to show that similar performance can be expected for the case of conducting objects and layered backgrounds

  19. Comparison of Spot and Time Weighted Averaging (TWA Sampling with SPME-GC/MS Methods for Trihalomethane (THM Analysis

    Directory of Open Access Journals (Sweden)

    Don-Roger Parkinson

    2016-02-01

    Full Text Available Water samples were collected and analyzed for conductivity, pH, temperature and trihalomethanes (THMs during the fall of 2014 at two monitored municipal drinking water source ponds. Both spot (or grab and time weighted average (TWA sampling methods were assessed over the same two day sampling time period. For spot sampling, replicate samples were taken at each site and analyzed within 12 h of sampling by both Headspace (HS- and direct (DI- solid phase microextraction (SPME sampling/extraction methods followed by Gas Chromatography/Mass Spectrometry (GC/MS. For TWA, a two day passive on-site TWA sampling was carried out at the same sampling points in the ponds. All SPME sampling methods undertaken used a 65-µm PDMS/DVB SPME fiber, which was found optimal for THM sampling. Sampling conditions were optimized in the laboratory using calibration standards of chloroform, bromoform, bromodichloromethane, dibromochloromethane, 1,2-dibromoethane and 1,2-dichloroethane, prepared in aqueous solutions from analytical grade samples. Calibration curves for all methods with R2 values ranging from 0.985–0.998 (N = 5 over the quantitation linear range of 3–800 ppb were achieved. The different sampling methods were compared for quantification of the water samples, and results showed that DI- and TWA- sampling methods gave better data and analytical metrics. Addition of 10% wt./vol. of (NH42SO4 salt to the sampling vial was found to aid extraction of THMs by increasing GC peaks areas by about 10%, which resulted in lower detection limits for all techniques studied. However, for on-site TWA analysis of THMs in natural waters, the calibration standard(s ionic strength conditions, must be carefully matched to natural water conditions to properly quantitate THM concentrations. The data obtained from the TWA method may better reflect actual natural water conditions.

  20. Profiling quinones in ambient air samples collected from the Athabasca region (Canada).

    Science.gov (United States)

    Wnorowski, Andrzej; Charland, Jean-Pierre

    2017-12-01

    This paper presents new findings on polycyclic aromatic hydrocarbon oxidation products-quinones that were collected in ambient air samples in the proximity of oil sands exploration. Quinones were characterized for their diurnal concentration variability, phase partitioning, and molecular size distribution. Gas-phase (GP) and particle-phase (PM) ambient air samples were collected separately in the summer; a lower quinone content was observed in the PM samples from continuous 24-h sampling than from combined 12-h sampling (day and night). The daytime/nocturnal samples demonstrated that nighttime conditions led to lower concentrations and some quinones not being detected. The highest quinone levels were associated with wind directions originating from oil sands exploration sites. The statistical correlation with primary pollutants directly emitted from oil sands industrial activities indicated that the bulk of the detected quinones did not originate directly from primary emission sources and that quinone formation paralleled a reduction in primary source NO x levels. This suggests a secondary chemical transformation of primary pollutants as the origin of the determined quinones. Measurements of 19 quinones included five that have not previously been reported in ambient air or in Standard Reference Material 1649a/1649b and seven that have not been previously measured in ambient air in the underivatized form. This is the first paper to report on quinone characterization in secondary organic aerosols originating from oil sands activities, to distinguish chrysenequinone and anthraquinone positional isomers in ambient air, and to report the requirement of daylight conditions for benzo[a]pyrenequinone and naphthacenequinone to be present in ambient air. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  1. Evaluation of sample preparation methods and optimization of nickel determination in vegetable tissues

    Directory of Open Access Journals (Sweden)

    Rodrigo Fernando dos Santos Salazar

    2011-02-01

    Full Text Available Nickel, although essential to plants, may be toxic to plants and animals. It is mainly assimilated by food ingestion. However, information about the average levels of elements (including Ni in edible vegetables from different regions is still scarce in Brazil. The objectives of this study were to: (a evaluate and optimize a method for preparation of vegetable tissue samples for Ni determination; (b optimize the analytical procedures for determination by Flame Atomic Absorption Spectrometry (FAAS and by Electrothermal Atomic Absorption (ETAAS in vegetable samples and (c determine the Ni concentration in vegetables consumed in the cities of Lorena and Taubaté in the Vale do Paraíba, State of São Paulo, Brazil. By means of the analytical technique for determination by ETAAS or FAAS, the results were validated by the test of analyte addition and recovery. The most viable method tested for quantification of this element was HClO4-HNO3 wet digestion. All samples but carrot tissue collected in Lorena contained Ni levels above the permitted by the Brazilian Ministry of Health. The most disturbing results, requiring more detailed studies, were the Ni concentrations measured in carrot samples from Taubaté, where levels were five times higher than permitted by Brazilian regulations.

  2. Collection of size fractionated particulate matter sample for neutron activation analysis in Japan

    International Nuclear Information System (INIS)

    Otoshi, Tsunehiko; Nakamatsu, Hiroaki; Oura, Yasuji; Ebihara, Mitsuru

    2004-01-01

    According to the decision of the 2001 Workshop on Utilization of Research Reactor (Neutron Activation Analysis (NAA) Section), size fractionated particulate matter collection for NAA was started from 2002 at two sites in Japan. The two monitoring sites, ''Tokyo'' and ''Sakata'', were classified into ''urban'' and ''rural''. In each site, two size fractions, namely PM 2-10 '' and PM 2 '' particles (aerodynamic particle size between 2 to 10 micrometer and less than 2 micrometer, respectively) were collected every month on polycarbonate membrane filters. Average concentrations of PM 10 (sum of PM 2-10 and PM 2 samples) during the common sampling period of August to November 2002 in each site were 0.031mg/m 3 in Tokyo, and 0.022mg/m 3 in Sakata. (author)

  3. Quartz analysis in gravimetric sampling

    International Nuclear Information System (INIS)

    Rex, D.A.

    1990-01-01

    An overview of the methods employed in the assessment of quartz exposure is provided. The principles and some of the problems associated with each method is discussed. The methods reviewed include wet chemical methods, X-ray diffraction and infrared absorption of which the latter two methods are deemed appropriate for analysing quartz on personal gravimetric collected samples. The implications of combining area samples collected over a six month period, and performing only a single quartz analysis rather than separate analyses, are considered. Finally, various options open to mines with regard to their involvement with quartz analysis are also briefly discussed. 35 refs., 6 figs., 1 tab

  4. Neonatal blood gas sampling methods | Goenka | South African ...

    African Journals Online (AJOL)

    There is little published guidance that systematically evaluates the different methods of neonatal blood gas sampling, where each method has its individual benefits and risks. This review critically surveys the available evidence to generate a comparison between arterial and capillary blood gas sampling, focusing on their ...

  5. An improved selective sampling method

    International Nuclear Information System (INIS)

    Miyahara, Hiroshi; Iida, Nobuyuki; Watanabe, Tamaki

    1986-01-01

    The coincidence methods which are currently used for the accurate activity standardisation of radio-nuclides, require dead time and resolving time corrections which tend to become increasingly uncertain as countrates exceed about 10 K. To reduce the dependence on such corrections, Muller, in 1981, proposed the selective sampling method using a fast multichannel analyser (50 ns ch -1 ) for measuring the countrates. It is, in many ways, more convenient and possibly potentially more reliable to replace the MCA with scalers and a circuit is described employing five scalers; two of them serving to measure the background correction. Results of comparisons using our new method and the coincidence method for measuring the activity of 60 Co sources yielded agree-ment within statistical uncertainties. (author)

  6. An algorithm to improve sampling efficiency for uncertainty propagation using sampling based method

    International Nuclear Information System (INIS)

    Campolina, Daniel; Lima, Paulo Rubens I.; Pereira, Claubia; Veloso, Maria Auxiliadora F.

    2015-01-01

    Sample size and computational uncertainty were varied in order to investigate sample efficiency and convergence of the sampling based method for uncertainty propagation. Transport code MCNPX was used to simulate a LWR model and allow the mapping, from uncertain inputs of the benchmark experiment, to uncertain outputs. Random sampling efficiency was improved through the use of an algorithm for selecting distributions. Mean range, standard deviation range and skewness were verified in order to obtain a better representation of uncertainty figures. Standard deviation of 5 pcm in the propagated uncertainties for 10 n-samples replicates was adopted as convergence criterion to the method. Estimation of 75 pcm uncertainty on reactor k eff was accomplished by using sample of size 93 and computational uncertainty of 28 pcm to propagate 1σ uncertainty of burnable poison radius. For a fixed computational time, in order to reduce the variance of the uncertainty propagated, it was found, for the example under investigation, it is preferable double the sample size than double the amount of particles followed by Monte Carlo process in MCNPX code. (author)

  7. Data collection costs in industrial environments for three occupational posture exposure assessment methods

    Science.gov (United States)

    2012-01-01

    Background Documentation of posture measurement costs is rare and cost models that do exist are generally naïve. This paper provides a comprehensive cost model for biomechanical exposure assessment in occupational studies, documents the monetary costs of three exposure assessment methods for different stakeholders in data collection, and uses simulations to evaluate the relative importance of cost components. Methods Trunk and shoulder posture variables were assessed for 27 aircraft baggage handlers for 3 full shifts each using three methods typical to ergonomic studies: self-report via questionnaire, observation via video film, and full-shift inclinometer registration. The cost model accounted for expenses related to meetings to plan the study, administration, recruitment, equipment, training of data collectors, travel, and onsite data collection. Sensitivity analyses were conducted using simulated study parameters and cost components to investigate the impact on total study cost. Results Inclinometry was the most expensive method (with a total study cost of € 66,657), followed by observation (€ 55,369) and then self report (€ 36,865). The majority of costs (90%) were borne by researchers. Study design parameters such as sample size, measurement scheduling and spacing, concurrent measurements, location and travel, and equipment acquisition were shown to have wide-ranging impacts on costs. Conclusions This study provided a general cost modeling approach that can facilitate decision making and planning of data collection in future studies, as well as investigation into cost efficiency and cost efficient study design. Empirical cost data from a large field study demonstrated the usefulness of the proposed models. PMID:22738341

  8. A Method for Choosing the Best Samples for Mars Sample Return.

    Science.gov (United States)

    Gordon, Peter R; Sephton, Mark A

    2018-05-01

    Success of a future Mars Sample Return mission will depend on the correct choice of samples. Pyrolysis-FTIR can be employed as a triage instrument for Mars Sample Return. The technique can thermally dissociate minerals and organic matter for detection. Identification of certain mineral types can determine the habitability of the depositional environment, past or present, while detection of organic matter may suggest past or present habitation. In Mars' history, the Theiikian era represents an attractive target for life search missions and the acquisition of samples. The acidic and increasingly dry Theiikian may have been habitable and followed a lengthy neutral and wet period in Mars' history during which life could have originated and proliferated to achieve relatively abundant levels of biomass with a wide distribution. Moreover, the sulfate minerals produced in the Theiikian are also known to be good preservers of organic matter. We have used pyrolysis-FTIR and samples from a Mars analog ferrous acid stream with a thriving ecosystem to test the triage concept. Pyrolysis-FTIR identified those samples with the greatest probability of habitability and habitation. A three-tier scoring system was developed based on the detection of (i) organic signals, (ii) carbon dioxide and water, and (iii) sulfur dioxide. The presence of each component was given a score of A, B, or C depending on whether the substance had been detected, tentatively detected, or not detected, respectively. Single-step (for greatest possible sensitivity) or multistep (for more diagnostic data) pyrolysis-FTIR methods informed the assignments. The system allowed the highest-priority samples to be categorized as AAA (or A*AA if the organic signal was complex), while the lowest-priority samples could be categorized as CCC. Our methods provide a mechanism with which to rank samples and identify those that should take the highest priority for return to Earth during a Mars Sample Return mission. Key Words

  9. Optimization and evaluation of multi-bed adsorbent tube method in collection of volatile organic compounds

    Science.gov (United States)

    Ho, Steven Sai Hang; Wang, Liqin; Chow, Judith C.; Watson, John G.; Xue, Yonggang; Huang, Yu; Qu, Linli; Li, Bowei; Dai, Wenting; Li, Lijuan; Cao, Junji

    2018-04-01

    The feasibility of using adsorbent tubes to collect volatile organic compounds (VOCs) has been demonstrated since the 1990's and standardized as Compendium Method TO-17 by the U.S. Environmental Protection Agency (U.S EPA). This paper investigates sampling and analytical variables on concentrations of 57 ozone (O3) precursors (C2-C12 aliphatic and aromatic VOCs) specified for the Photochemical Assessment Monitoring Station (PAMS). Laboratory and field tests examined multi-bed adsorbent tubes containing a sorbate combination of Tenax TA, Carbograph 1 TD, and Carboxen 1003. Analyte stabilities were influenced by both collection tube temperature and ambient O3 concentrations. Analytes degraded during storage, while blank levels were elevated by passive adsorption. Adsorbent tube storage under cold temperatures (- 10 °C) in a preservation container filled with solid silica gel and anhydrous calcium sulfate (CaSO4) ensured sample integrity. A high efficiency (> 99%) O3 scrubber (i.e., copper coil tube filled with saturated potassium iodide [KI]) removed O3 (i.e., air stream with a sampling capacity of 30 h. Water vapor scrubbers interfered with VOC measurements. The optimal thermal desorption-gas chromatography/mass spectrometry (TD-GC/MS) desorption time of 8 min was found at 330 °C. Good linearity (R2 > 0.995) was achieved for individual analyte calibrations (with the exception of acetylene) for mixing ratios of 0.08-1.96 ppbv. The method detection limits (MDLs) were below 0.055 ppbv for a 3 L sample volume. Replicate analyses showed relative standard deviations (RSDs) of < 10%, with the majority of the analytes within < 5%.

  10. Sample preparation method for scanning force microscopy

    CERN Document Server

    Jankov, I R; Szente, R N; Carreno, M N P; Swart, J W; Landers, R

    2001-01-01

    We present a method of sample preparation for studies of ion implantation on metal surfaces. The method, employing a mechanical mask, is specially adapted for samples analysed by Scanning Force Microscopy. It was successfully tested on polycrystalline copper substrates implanted with phosphorus ions at an acceleration voltage of 39 keV. The changes of the electrical properties of the surface were measured by Kelvin Probe Force Microscopy and the surface composition was analysed by Auger Electron Spectroscopy.

  11. Multisite recruitment and data collection among older adults: exploring methods to conserve human and financial resources.

    Science.gov (United States)

    McCarthy, Valerie Lander; Cassidy, Karen

    2012-01-01

    The purpose of this article is to describe strategies that were effective in recruitment and data collection among older adults in 3 quantitative studies while decreasing costs in terms of time and money. Factors effective in reducing use of investigators' time and expenses included limiting exclusion of data because of abnormal Mini-Cog scores by careful initial screening and avoiding repeated reminders or follow-up, collecting data in small groups, collapsing consent, dementia screening, and data collection into single sessions, as well as accommodating for sensory and literacy deficits. The cross-sectional, descriptive studies were conducted among community-dwelling older adults attending senior citizen centers and among older adults in independent or assisted living apartments within continuing care retirement communities (CCRCs). In the latest study, a convenience sample (N=152) was recruited and data collection was completed in 4 weeks at a total cost of less than $5,000. Methods common to qualitative research and those commonly used in community-based research were adapted to reduce time and costs for recruitment, screening, and data collection. Given limited availability of research funding, other nursing researchers may find one or more of these methods useful.

  12. Comparison of diffusion- and pumped-sampling methods to monitor volatile organic compounds in ground water, Massachusetts Military Reservation, Cape Cod, Massachusetts, July 1999-December 2002

    Science.gov (United States)

    Archfield, Stacey A.; LeBlanc, Denis R.

    2005-01-01

    To evaluate diffusion sampling as an alternative method to monitor volatile organic compound (VOC) concentrations in ground water, concentrations in samples collected by traditional pumped-sampling methods were compared to concentrations in samples collected by diffusion-sampling methods for 89 monitoring wells at or near the Massachusetts Military Reservation, Cape Cod. Samples were analyzed for 36 VOCs. There was no substantial difference between the utility of diffusion and pumped samples to detect the presence or absence of a VOC. In wells where VOCs were detected, diffusion-sample concentrations of tetrachloroethene (PCE) and trichloroethene (TCE) were significantly lower than pumped-sample concentrations. Because PCE and TCE concentrations detected in the wells dominated the calculation of many of the total VOC concentrations, when VOC concentrations were summed and compared by sampling method, visual inspection also showed a downward concentration bias in the diffusion-sample concentration. The degree to which pumped- and diffusion-sample concentrations agreed was not a result of variability inherent within the sampling methods or the diffusion process itself. A comparison of the degree of agreement in the results from the two methods to 13 quantifiable characteristics external to the sampling methods offered only well-screen length as being related to the degree of agreement between the methods; however, there is also evidence to indicate that the flushing rate of water through the well screen affected the agreement between the sampling methods. Despite poor agreement between the concentrations obtained by the two methods at some wells, the degree to which the concentrations agree at a given well is repeatable. A one-time, well-bywell comparison between diffusion- and pumped-sampling methods could determine which wells are good candidates for the use of diffusion samplers. For wells with good method agreement, the diffusion-sampling method is a time

  13. Sampling and analysis methods for geothermal fluids and gases

    Energy Technology Data Exchange (ETDEWEB)

    Watson, J.C.

    1978-07-01

    The sampling procedures for geothermal fluids and gases include: sampling hot springs, fumaroles, etc.; sampling condensed brine and entrained gases; sampling steam-lines; low pressure separator systems; high pressure separator systems; two-phase sampling; downhole samplers; and miscellaneous methods. The recommended analytical methods compiled here cover physical properties, dissolved solids, and dissolved and entrained gases. The sequences of methods listed for each parameter are: wet chemical, gravimetric, colorimetric, electrode, atomic absorption, flame emission, x-ray fluorescence, inductively coupled plasma-atomic emission spectroscopy, ion exchange chromatography, spark source mass spectrometry, neutron activation analysis, and emission spectrometry. Material on correction of brine component concentrations for steam loss during flashing is presented. (MHR)

  14. Collecting Information for Rating Global Assessment of Functioning (GAF): Sources of Information and Methods for Information Collection.

    Science.gov (United States)

    I H, Monrad Aas

    2014-11-01

    Global Assessment of Functioning (GAF) is an assessment instrument that is known worldwide. It is widely used for rating the severity of illness. Results from evaluations in psychiatry should characterize the patients. Rating of GAF is based on collected information. The aim of the study is to identify the factors involved in collecting information that is relevant for rating GAF, and gaps in knowledge where it is likely that further development would play a role for improved scoring. A literature search was conducted with a combination of thorough hand search and search in the bibliographic databases PubMed, PsycINFO, Google Scholar, and Campbell Collaboration Library of Systematic Reviews. Collection of information for rating GAF depends on two fundamental factors: the sources of information and the methods for information collection. Sources of information are patients, informants, health personnel, medical records, letters of referral and police records about violence and substance abuse. Methods for information collection include the many different types of interview - unstructured, semi-structured, structured, interviews for Axis I and II disorders, semistructured interviews for rating GAF, and interviews of informants - as well as instruments for rating symptoms and functioning, and observation. The different sources of information, and methods for collection, frequently result in inconsistencies in the information collected. The variation in collected information, and lack of a generally accepted algorithm for combining collected information, is likely to be important for rated GAF values, but there is a fundamental lack of knowledge about the degree of importance. Research to improve GAF has not reached a high level. Rated GAF values are likely to be influenced by both the sources of information used and the methods employed for information collection, but the lack of research-based information about these influences is fundamental. Further development of

  15. Optimizing detection of noble gas emission at a former UNE site: sample strategy, collection, and analysis

    Science.gov (United States)

    Kirkham, R.; Olsen, K.; Hayes, J. C.; Emer, D. F.

    2013-12-01

    Underground nuclear tests may be first detected by seismic or air samplers operated by the CTBTO (Comprehensive Nuclear-Test-Ban Treaty Organization). After initial detection of a suspicious event, member nations may call for an On-Site Inspection (OSI) that in part, will sample for localized releases of radioactive noble gases and particles. Although much of the commercially available equipment and methods used for surface and subsurface environmental sampling of gases can be used for an OSI scenario, on-site sampling conditions, required sampling volumes and establishment of background concentrations of noble gases require development of specialized methodologies. To facilitate development of sampling equipment and methodologies that address OSI sampling volume and detection objectives, and to collect information required for model development, a field test site was created at a former underground nuclear explosion site located in welded volcanic tuff. A mixture of SF-6, Xe127 and Ar37 was metered into 4400 m3 of air as it was injected into the top region of the UNE cavity. These tracers were expected to move towards the surface primarily in response to barometric pumping or through delayed cavity pressurization (accelerated transport to minimize source decay time). Sampling approaches compared during the field exercise included sampling at the soil surface, inside surface fractures, and at soil vapor extraction points at depths down to 2 m. Effectiveness of various sampling approaches and the results of tracer gas measurements will be presented.

  16. Integrated Data Collection Analysis (IDCA) Program - SSST Testing Methods

    Energy Technology Data Exchange (ETDEWEB)

    Sandstrom, Mary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Geoffrey W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Preston, Daniel N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pollard, Colin J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Warner, Kirstin F. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Remmers, Daniel L. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Sorensen, Daniel N. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Whinnery, LeRoy L. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Phillips, Jason J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Shelley, Timothy J. [Bureau of Alcohol, Tobacco and Firearms (ATF), Huntsville, AL (United States); Reyes, Jose A. [Applied Research Associates, Tyndall AFB, FL (United States); Hsu, Peter C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reynolds, John G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-03-25

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the methods used for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis during the IDCA program. These methods changed throughout the Proficiency Test and the reasons for these changes are documented in this report. The most significant modifications in standard testing methods are: 1) including one specified sandpaper in impact testing among all the participants, 2) diversifying liquid test methods for selected participants, and 3) including sealed sample holders for thermal testing by at least one participant. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study will suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.

  17. How to take environmental samples for stable isotope analyses

    International Nuclear Information System (INIS)

    Rogers, K.M.

    2009-01-01

    It is possible to analyse a diverse range of samples for environmental investigations. The main types are soil/sediments, vegetation, fauna, shellfish, waste and water. Each type of samples requires different storage and collection methods. Outlined here are the preferred methods of collection to ensure maximum sample integrity and reliability. (author).

  18. How to take environmental samples for stable isotope analyses

    International Nuclear Information System (INIS)

    Rogers, K.M.

    2013-01-01

    It is possible to analyse a diverse range of samples for environmental investigations. The main types are soil/sediments, vegetation, fauna, shellfish, waste and water. Each type of samples requires different storage and collection methods. Outlined here are the preferred methods of collection to ensure maximum sample integrity and reliability. (author).

  19. How to take environmental samples for stable isotope analyses

    International Nuclear Information System (INIS)

    Rogers, K.M.

    2012-01-01

    It is possible to analyse a diverse range of samples for environmental investigations. The main types are soil/sediments, vegetation, fauna, shellfish, waste and water. Each type of samples requires different storage and collection methods. Outlined here are the preferred methods of collection to ensure maximum sample integrity and reliability. (author).

  20. How to take environmental samples for stable isotope analyses

    International Nuclear Information System (INIS)

    Rogers, K.M.

    2009-01-01

    It is possible to analyse a diverse range of samples for environmental investigations. The main types are soil/sediments, vegetation, fauna, shellfish, waste and water. Each type of samples requires different storage and collection methods. Outlined here are the preferred methods of collection to ensure maximum sample integrity and reliability. (author)

  1. Pre-Mission Input Requirements to Enable Successful Sample Collection by a Remote Field/EVA Team

    Science.gov (United States)

    Cohen, B. A.; Young, K. E.; Lim, D. S.

    2015-01-01

    objectives than samples collected in the absence of this premission information. We conducted three tests of this hypothesis. Our investigation was designed to document processes, tools and procedures for crew sampling of planetary targets. This is not meant to be a blind, controlled test of crew efficacy, but rather an effort to recognize the relevant variables that enter into sampling protocol and to develop recommendations for crew and backroom training in future endeavors. Methods: One of the primary FINESSE field deployment objectives was to collect impact melt rocks and impact melt-bearing breccias from a number of locations around the WCIS structure to enable high precision geochronology of the crater to be performed [1]. We conducted three tests at WCIS after two full days of team participation in field site activities, including using remote sensing data and geologic maps, hiking overland to become familiar with the terrain, and examining previously-collected samples from other islands. In addition, the team members shared their projects and techniques with the entire team. We chose our "crew members" as volunteers from the team, all of whom had had moderate training in geologic fieldwork and became familiar with the general field setting. The first two tests were short, focused tests of our hypothesis. Test A was to obtain hydrothermal vugs; Test B was to obtain impact melt and intrusive rock as well as the contact between the two to check for contact metamorphism and age differences. In both cases, the test director had prior knowledge of the site geology and had developed a study-specific objective for sampling prior to deployment. Prior to the field deployment, the crewmember was briefed on the sampling objective and the laboratory techniques that would be used on the samples. At the field sites (Fig. 2), the crewmember was given 30 minutes to survey a small section of outcrop (10-15 m) and acquire a suite of three samples. The crewmember talked through his

  2. 20 CFR 361.13 - Procedures for salary offset: Methods of collection.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false Procedures for salary offset: Methods of collection. 361.13 Section 361.13 Employees' Benefits RAILROAD RETIREMENT BOARD INTERNAL ADMINISTRATION... § 361.13 Procedures for salary offset: Methods of collection. (a) General. A debt will be collected by...

  3. Evaluation of acid leaching method for the determination of uranium in fecal samples from occupational workers at Tarapur

    International Nuclear Information System (INIS)

    Raveendran, Nanda; Dubla, Rupali; Yadav, J.R.; Rao, D.D.; Baburajan, A.

    2015-01-01

    Assessment of internal contamination due to inhalation, ingestion or injection of radionuclides to occupational workers is carried out by analysis of excreta samples and whole body counting. Routine monitoring of radiation workers for assessing actinides intake are done either by urine or fecal sample analysis. This paper deals with the evaluation of analytical method for the determination of isotopes of uranium in fecal samples submitted by occupational workers from operating plants at Tarapur. The method involves sample ashing, addition of 232 U tracer for radiochemical recovery and acid leaching preconcentration stage followed by anion exchange separation. Thirteen routine fecal samples submitted by radiation workers under their routine monitoring practices were collected and analyzed. Radiochemical tracer recovery was obtained in the range of 52% to 86.4 % with a mean and standard deviation of 64.7% and 12.3% respectively. (author)

  4. Improved Methods of Carnivore Faecal Sample Preservation, DNA Extraction and Quantification for Accurate Genotyping of Wild Tigers

    Science.gov (United States)

    Harika, Katakam; Mahla, Ranjeet Singh; Shivaji, Sisinthy

    2012-01-01

    Background Non-invasively collected samples allow a variety of genetic studies on endangered and elusive species. However due to low amplification success and high genotyping error rates fewer samples can be identified up to the individual level. Number of PCRs needed to obtain reliable genotypes also noticeably increase. Methods We developed a quantitative PCR assay to measure and grade amplifiable nuclear DNA in feline faecal extracts. We determined DNA degradation in experimentally aged faecal samples and tested a suite of pre-PCR protocols to considerably improve DNA retrieval. Results Average DNA concentrations of Grade I, II and III extracts were 982pg/µl, 9.5pg/µl and 0.4pg/µl respectively. Nearly 10% of extracts had no amplifiable DNA. Microsatellite PCR success and allelic dropout rates were 92% and 1.5% in Grade I, 79% and 5% in Grade II, and 54% and 16% in Grade III respectively. Our results on experimentally aged faecal samples showed that ageing has a significant effect on quantity and quality of amplifiable DNA (pDNA degradation occurs within 3 days of exposure to direct sunlight. DNA concentrations of Day 1 samples stored by ethanol and silica methods for a month varied significantly from fresh Day 1 extracts (p0.05). DNA concentrations of fresh tiger and leopard faecal extracts without addition of carrier RNA were 816.5pg/µl (±115.5) and 690.1pg/µl (±207.1), while concentrations with addition of carrier RNA were 49414.5pg/µl (±9370.6) and 20982.7pg/µl (±6835.8) respectively. Conclusions Our results indicate that carnivore faecal samples should be collected as freshly as possible, are better preserved by two-step method and should be extracted with addition of carrier RNA. We recommend quantification of template DNA as this facilitates several downstream protocols. PMID:23071624

  5. Radon exhalation rates from soil and sand samples collected from the vicinity of Yamuna river

    International Nuclear Information System (INIS)

    Garg, A.K.; Sushil Kumar; Chauhan, Pooja; Chauhan, R.P.

    2011-01-01

    Soil, sand and stones are the most popular building materials for Indian dwellings. Radon is released into ambient air from these materials due to ubiquitous uranium and radium in them, thus increasing the airborne radon concentration. The radioactivity in sand and soils is related to radioactivity in the rocks from which they are formed. These materials contain varying amount of uranium. In the present investigation, the radon emanated from soil and sand samples from different locations in the vicinity of Yamuna river has been estimated. The samples have been collected from different locations near the Yamuna river. The samples collecting sites are from Yamunanagar in Haryana to Delhi. The radon concentration in different samples has been calculated, based upon the data, the mass and the surface exhalation rates of radon emanated from them have also been calculated

  6. Randomized Comparison of Two Vaginal Self-Sampling Methods for Human Papillomavirus Detection: Dry Swab versus FTA Cartridge

    OpenAIRE

    Catarino, Rosa; Vassilakos, Pierre; Bilancioni, Aline; Vanden Eynde, Mathieu; Meyer-Hamme, Ulrike; Menoud, Pierre-Alain; Guerry, Fr?d?ric; Petignat, Patrick

    2015-01-01

    Background Human papillomavirus (HPV) self-sampling (self-HPV) is valuable in cervical cancer screening. HPV testing is usually performed on physician-collected cervical smears stored in liquid-based medium. Dry filters and swabs are an alternative. We evaluated the adequacy of self-HPV using two dry storage and transport devices, the FTA cartridge and swab. Methods A total of 130 women performed two consecutive self-HPV samples. Randomization determined which of the two tests was performed f...

  7. 7 CFR 3.83 - Procedures for salary offset: methods of collection.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 1 2010-01-01 2010-01-01 false Procedures for salary offset: methods of collection. 3.83 Section 3.83 Agriculture Office of the Secretary of Agriculture DEBT MANAGEMENT Federal Salary Offset § 3.83 Procedures for salary offset: methods of collection. (a) General. A debt will be collected...

  8. On Angular Sampling Methods for 3-D Spatial Channel Models

    DEFF Research Database (Denmark)

    Fan, Wei; Jämsä, Tommi; Nielsen, Jesper Ødum

    2015-01-01

    This paper discusses generating three dimensional (3D) spatial channel models with emphasis on the angular sampling methods. Three angular sampling methods, i.e. modified uniform power sampling, modified uniform angular sampling, and random pairing methods are proposed and investigated in detail....... The random pairing method, which uses only twenty sinusoids in the ray-based model for generating the channels, presents good results if the spatial channel cluster is with a small elevation angle spread. For spatial clusters with large elevation angle spreads, however, the random pairing method would fail...... and the other two methods should be considered....

  9. Estimating HIES Data through Ratio and Regression Methods for Different Sampling Designs

    Directory of Open Access Journals (Sweden)

    Faqir Muhammad

    2007-01-01

    Full Text Available In this study, comparison has been made for different sampling designs, using the HIES data of North West Frontier Province (NWFP for 2001-02 and 1998-99 collected from the Federal Bureau of Statistics, Statistical Division, Government of Pakistan, Islamabad. The performance of the estimators has also been considered using bootstrap and Jacknife. A two-stage stratified random sample design is adopted by HIES. In the first stage, enumeration blocks and villages are treated as the first stage Primary Sampling Units (PSU. The sample PSU’s are selected with probability proportional to size. Secondary Sampling Units (SSU i.e., households are selected by systematic sampling with a random start. They have used a single study variable. We have compared the HIES technique with some other designs, which are: Stratified Simple Random Sampling. Stratified Systematic Sampling. Stratified Ranked Set Sampling. Stratified Two Phase Sampling. Ratio and Regression methods were applied with two study variables, which are: Income (y and Household sizes (x. Jacknife and Bootstrap are used for variance replication. Simple Random Sampling with sample size (462 to 561 gave moderate variances both by Jacknife and Bootstrap. By applying Systematic Sampling, we received moderate variance with sample size (467. In Jacknife with Systematic Sampling, we obtained variance of regression estimator greater than that of ratio estimator for a sample size (467 to 631. At a sample size (952 variance of ratio estimator gets greater than that of regression estimator. The most efficient design comes out to be Ranked set sampling compared with other designs. The Ranked set sampling with jackknife and bootstrap, gives minimum variance even with the smallest sample size (467. Two Phase sampling gave poor performance. Multi-stage sampling applied by HIES gave large variances especially if used with a single study variable.

  10. Web-based Survey Data Collection With Peer Support and Advocacy Organizations: Implications of Participatory Methods.

    Science.gov (United States)

    Ostrow, Laysha; Penney, Darby; Stuart, Elizabeth; Leaf, Phillip J

    2017-01-01

    The 2012 National Survey of Peer-Run Organizations is one of the first to survey a nationally representative sample of mental health peer-run organizations, nonprofit venues for support and advocacy which are defined by people with psychiatric histories being in positions of authority and control. This paper describes data collection methods and demonstrates how participatory strategies to involve people with psychiatric histories intersected with Internet research to achieve study aims. People with psychiatric histories were involved in designing and implementing a web-based survey to collect data on peer-run organizations' operations and views on national policy. Participatory approaches were used throughout design, data collection analysis, and dissemination. The extensive involvement of people with psychiatric histories in project design and implementation were important strategies that contributed to this study's success.

  11. Mobile sources of polycyclic aromatic hydrocarbons (PAH) and nitro-PAH: Results of samples collected in a roadway tunnel

    International Nuclear Information System (INIS)

    Benner, B.A. Jr.; Gordon, G.E.; Wise, S.A.

    1987-01-01

    A recent review article emphasized the need for further characterizations of the carbonaceous fraction of mobile source emissions, particularly with the impending removal of lead alkyl octane boosters and bromine-containing lead scavengers from regular leaded gasolines. The lead and bromine emitted from the combustion of these fuels have been used as tracers of mobile source emissions for a number of years. Single vehicle emission studies have shed light on the relationship between engine operating parameters and the chemical characteristics of the emissions but they are not suitable for use in source apportionment studies which require emission data from a large number of different vehicles. Air particulate samples collected near a busy highway or in a roadway tunnel would be more appropriate for use in estimating the mobile source contribution of organic compounds to a region. Suspended particle samples collected in a heavily-travelled roadway tunnel (Baltimore Harbor Tunnel, Baltimore, Maryland) were characterized for polycyclic aromatic hydrocarbons (PAH) and some nitro-PAH by gas and liquid chromatographic techniques. These samples included those collected on Teflon filters and on glass fiber filters for investigating any differences in samples collected on an inert (Teflon) and more reactive (glass-fiber) medium. All samples collected on Teflon were backed-up with polyurethane foam plugs (PUF) which trapped any inherent vapor-phase PAH as well as any compounds ''blown-off'' the particles during collection

  12. Detoxification Of Ochratoxin AIN Green Coffee Beans By Physical Methods With Studying Genotoxicity Of Treated Samples

    International Nuclear Information System (INIS)

    FARAG, S.A.; SHAMS EL DIEEN, N.M.M.; EL-SIDEEK, L

    2010-01-01

    Ochratoxin A (OTA) is potently nephrotoxic, teratogenic and carcinogenic, and the potency was varied markedly between species and sexes. Unfortunately, OTA are present due to mold contamination in different food stuffs such as coffee bean, therefore, the present study was carried out on collected imported coffee samples from super markets in Egypt. The isolation and identification proved presence of Penicilli sp. and Aspergillus sp. whereas the last one was dominant in two samples as A. niger and A. ochoruses. Determination of OTA by using HPLC analysis showed presence of high levels than the allowance levels in green coffee beans (more than 5 μg/kg; ppb). In addition, another group of collected samples as roasted coffee beans indicated the presence of high toxic concentrations of OTA. The study was then conducted on samples contain the highest OTA content by using some physical methods as gamma irradiation (5 and 10 kGy), charcoal (powder, granules), roasting (at 200 0 C for 7-10 min and 20 min). The results showed that proposed physical methods, mainly gamma irradiation and charcoal, could be efficient to decrease OTA in green beans coffee without produce toxic substance as well as non-significant changes in its properties. In addition, safety of resulted coffee beans after treatments were checked by ESR and genotoxicity test, which raise the preferability of gamma irradiation (10 kGy) treatment before using medium roasting to get coffee beans free from OTA

  13. Interval sampling methods and measurement error: a computer simulation.

    Science.gov (United States)

    Wirth, Oliver; Slaven, James; Taylor, Matthew A

    2014-01-01

    A simulation study was conducted to provide a more thorough account of measurement error associated with interval sampling methods. A computer program simulated the application of momentary time sampling, partial-interval recording, and whole-interval recording methods on target events randomly distributed across an observation period. The simulation yielded measures of error for multiple combinations of observation period, interval duration, event duration, and cumulative event duration. The simulations were conducted up to 100 times to yield measures of error variability. Although the present simulation confirmed some previously reported characteristics of interval sampling methods, it also revealed many new findings that pertain to each method's inherent strengths and weaknesses. The analysis and resulting error tables can help guide the selection of the most appropriate sampling method for observation-based behavioral assessments. © Society for the Experimental Analysis of Behavior.

  14. Simultaneous Determination of TetracyclinesResidues in Bovine Milk Samples by Solid Phase Extraction and HPLC-FL Method

    Directory of Open Access Journals (Sweden)

    Mehra Mesgari Abbasi

    2011-06-01

    Full Text Available Introduction:Tetracyclines (TCs are widely used in animal husbandry and their residues in milk may resultinharmful effects on human. The aim of this study was to investigate the presence of TCs residues in various bovine milk samples from local markets of Ardabil, Iran. Methods:One hundred and fourteen pasteurized, sterilized and raw milk samples were collected from markets of Ardabil. Tetracycline, Oxytetracycline and Chlortetracycline (TCs residues extraction carried out by Solid Phase Extraction method. Determination of TCs residues were performed by high performance liquid chromatography (HPLC method using Fluorescence detector.Results: The mean of total TCs residues in all samples (114 samples was 97.6 ±16.9ng/g and that of pasteurized, sterilized and raw milk samples were 87.1 ± 17.7, 112.0 ± 57.3 and 154.0 ± 66.3ng/g respectively. Twenty five point four percent of the all samples, and24.4%, 30% and 28.6% of the pasteurized, sterilized and raw milk samples, respectively had higher TCs residues than the recommended maximum levels (100ng/g. Conclusion:This study indicates the presence of tetracycline residues more than allowed amount. Regulatory authorities should ensure proper withdrawal period before milking the animals and definite supervisions are necessary on application of these drugs.

  15. Comparison of Uriswab to alternative methods for urine culture collection and transport: confirmation of standard culture methodology for investigation of urinary tract infections.

    Science.gov (United States)

    Rennie, Robert P; Turnbull, Lee-Ann; Gauchier-Pitts, Kaylee; Bennett, Tracy; Dyrland, Debbie; Blonski, Susan

    2016-08-01

    The ability to isolate and identify causative agents of urinary tract infections relies primarily on the quality of the urine sample that is submitted to the microbiology. The most important factors are the method of collection, the maintenance of viability of the potential pathogens during transport, and standardization of the culturing of the urine sample. This report is a composite of several investigations comparing collection and transport on urine culture paddles, with a preservative urine sponge (Uriswab), and a comparison of Uriswab with the BD preservative transport tube as methods of preservation of urinary pathogens. Primary studies showed that Uriswab maintained significantly more urinary pathogens than the urine culture paddle with fewer mixed or contaminated cultures. The two preservative transport systems were comparable for maintenance of viability of the pathogens, but there were fewer mixed cultures when samples were collected with Uriswab. This study confirms the importance of a standard volume of 1 μL of urine for culture. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Wet-digestion of environmental sample using silver-mediated electrochemical method

    International Nuclear Information System (INIS)

    Kuwabara, Jun

    2010-01-01

    An application of silver-mediated electrochemical method to environmental samples as the effective digestion method for iodine analysis was tried. Usual digestion method for 129 I in many type of environmental sample is combustion method using quartz glass tube. Chemical yield of iodine on the combustion method reduce depending on the type of sample. The silver-mediated electrochemical method is expected to achieve very low loss of iodine. In this study, dried kombu (Laminaria) sample was tried to digest with electrochemical cell. At the case of 1g of sample, digestion was completed for about 24 hours under the electric condition of <10V and <2A. After the digestion, oxidized species of iodine was reduced to iodide by adding sodium sulfite. And then the precipitate of silver iodide was obtained. (author)

  17. A flexible method for multi-level sample size determination

    International Nuclear Information System (INIS)

    Lu, Ming-Shih; Sanborn, J.B.; Teichmann, T.

    1997-01-01

    This paper gives a flexible method to determine sample sizes for both systematic and random error models (this pertains to sampling problems in nuclear safeguard questions). In addition, the method allows different attribute rejection limits. The new method could assist achieving a higher detection probability and enhance inspection effectiveness

  18. [Analysis of qualitative data collection methods used in adolescent research].

    Science.gov (United States)

    Ndengeyingoma, Assumpta; De Montigny, Francine; Miron, Jean-Marie

    2013-03-01

    There has been remarkable growth in research on adolescents in the last decade, particularly in nursing science. The goal of this article is to produce a synthesis of findings justifying the use of qualitative methods in collecting data from adolescents. A literature review identified relevant articles (N : 27) from digital databases. While the studies done on adolescents were on different topics, the data collection methods were often similar. Most of the studies used more than one technique to reconcile scientific rigour and the way the adolescents expressed themselves. In order to understand a phenomenon, its context and the meaning given to the experience proved essential. In qualitative research on adolescents, it is important to use data collection methods that make it possible to clearly target the experience explored and to orient and guide the individual in deepening that experience in order to favour the emergence of his or her point of view. Data collection methods based on written communication have to be complemented with other methods more focused on oral communication so as to draw out interpretations reflecting adolescents' points of view as accurately as possible.

  19. Inside-sediment partitioning of PAH, PCB and organochlorine compounds and inferences on sampling and normalization methods

    International Nuclear Information System (INIS)

    Opel, Oliver; Palm, Wolf-Ulrich; Steffen, Dieter; Ruck, Wolfgang K.L.

    2011-01-01

    Comparability of sediment analyses for semivolatile organic substances is still low. Neither screening of the sediments nor organic-carbon based normalization is sufficient to obtain comparable results. We are showing the interdependency of grain-size effects with inside-sediment organic-matter distribution for PAH, PCB and organochlorine compounds. Surface sediment samples collected by Van-Veen grab were sieved and analyzed for 16 PAH, 6 PCB and 18 organochlorine pesticides (OCP) as well as organic-matter content. Since bulk concentrations are influenced by grain-size effects themselves, we used a novel normalization method based on the sum of concentrations in the separate grain-size fractions of the sediments. By calculating relative normalized concentrations, it was possible to clearly show underlying mechanisms throughout a heterogeneous set of samples. Furthermore, we were able to show that, for comparability, screening at <125 μm is best suited and can be further improved by additional organic-carbon normalization. - Research highlights: → New method for the comparison of heterogeneous sets of sediment samples. → Assessment of organic pollutants partitioning mechanisms in sediments. → Proposed method for more comparable sediment sampling. - Inside-sediment partitioning mechanisms are shown using a new mathematical approach and discussed in terms of sediment sampling and normalization.

  20. Neutron activation analysis of certified samples by the absolute method

    Science.gov (United States)

    Kadem, F.; Belouadah, N.; Idiri, Z.

    2015-07-01

    The nuclear reactions analysis technique is mainly based on the relative method or the use of activation cross sections. In order to validate nuclear data for the calculated cross section evaluated from systematic studies, we used the neutron activation analysis technique (NAA) to determine the various constituent concentrations of certified samples for animal blood, milk and hay. In this analysis, the absolute method is used. The neutron activation technique involves irradiating the sample and subsequently performing a measurement of the activity of the sample. The fundamental equation of the activation connects several physical parameters including the cross section that is essential for the quantitative determination of the different elements composing the sample without resorting to the use of standard sample. Called the absolute method, it allows a measurement as accurate as the relative method. The results obtained by the absolute method showed that the values are as precise as the relative method requiring the use of standard sample for each element to be quantified.

  1. THE USE OF RANKING SAMPLING METHOD WITHIN MARKETING RESEARCH

    Directory of Open Access Journals (Sweden)

    CODRUŢA DURA

    2011-01-01

    Full Text Available Marketing and statistical literature available to practitioners provides a wide range of sampling methods that can be implemented in the context of marketing research. Ranking sampling method is based on taking apart the general population into several strata, namely into several subdivisions which are relatively homogenous regarding a certain characteristic. In fact, the sample will be composed by selecting, from each stratum, a certain number of components (which can be proportional or non-proportional to the size of the stratum until the pre-established volume of the sample is reached. Using ranking sampling within marketing research requires the determination of some relevant statistical indicators - average, dispersion, sampling error etc. To that end, the paper contains a case study which illustrates the actual approach used in order to apply the ranking sample method within a marketing research made by a company which provides Internet connection services, on a particular category of customers – small and medium enterprises.

  2. Evaluation of a New Technique for iFOBT Utilising a New Sample Collection Device with Increased Buffer Stability.

    Science.gov (United States)

    Bruns-Toepler, Markus; Hardt, Philip

    2017-07-01

    The aims of the present study were: (i) Evaluate specificity and sensitivity of Hb Smart enzyme-linked immunosorbent assay (ELISA) (ScheBo Biotech) compared to colonoscopy results and (ii) assess stability of a new sample collection device containing a newly formulated buffer to extract haemoglobin using buffer and stool samples spiked with defined concentrations of haemoglobin. Stool samples were quantified with the ELISA method. The stability of haemoglobin in the extraction buffer and in native stool samples, respectively, was determined daily by ELISA during storage for 5 days at 4°C and at room temperature after addition of haemoglobin. Haemoglobin ELISA had a sensitivity of 78.4% for detection of CRC with a specificity of 98%. Haemoglobin extracted in corresponding extraction buffer demonstrated stability throughout storage for 5 days at 4°C and at room temperature. Hb Smart represents a very promising tool for large-scale screening of CRC with regard to sample handling, stability and analysis of haemoglobin in faeces. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  3. 76 FR 79702 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-12-22

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential... Qualitative Feedback on Agency Service Delivery AGENCY: National Institute of Mental Health (NIMH), HHS... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  4. 76 FR 19826 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-04-08

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential... Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY... (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...

  5. 76 FR 21746 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-04-18

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential... of Qualitative Feedback on Agency Service Delivery AGENCY: Agency for Healthcare Research and Quality... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  6. Research-Grade 3D Virtual Astromaterials Samples: Novel Visualization of NASA's Apollo Lunar Samples and Antarctic Meteorite Samples to Benefit Curation, Research, and Education

    Science.gov (United States)

    Blumenfeld, E. H.; Evans, C. A.; Oshel, E. R.; Liddle, D. A.; Beaulieu, K. R.; Zeigler, R. A.; Righter, K.; Hanna, R. D.; Ketcham, R. A.

    2017-01-01

    NASA's vast and growing collections of astromaterials are both scientifically and culturally significant, requiring unique preservation strategies that need to be recurrently updated to contemporary technological capabilities and increasing accessibility demands. New technologies have made it possible to advance documentation and visualization practices that can enhance conservation and curation protocols for NASA's Astromaterials Collections. Our interdisciplinary team has developed a method to create 3D Virtual Astromaterials Samples (VAS) of the existing collections of Apollo Lunar Samples and Antarctic Meteorites. Research-grade 3D VAS will virtually put these samples in the hands of researchers and educators worldwide, increasing accessibility and visibility of these significant collections. With new sample return missions on the horizon, it is of primary importance to develop advanced curation standards for documentation and visualization methodologies.

  7. Predictors of mother and child DNA yields in buccal cell samples collected in pediatric cancer epidemiologic studies: a report from the Children's Oncology group.

    Science.gov (United States)

    Poynter, Jenny N; Ross, Julie A; Hooten, Anthony J; Langer, Erica; Blommer, Crystal; Spector, Logan G

    2013-08-12

    Collection of high-quality DNA is essential for molecular epidemiology studies. Methods have been evaluated for optimal DNA collection in studies of adults; however, DNA collection in young children poses additional challenges. Here, we have evaluated predictors of DNA quantity in buccal cells collected for population-based studies of infant leukemia (N = 489 mothers and 392 children) and hepatoblastoma (HB; N = 446 mothers and 412 children) conducted through the Children's Oncology Group. DNA samples were collected by mail using mouthwash (for mothers and some children) and buccal brush (for children) collection kits and quantified using quantitative real-time PCR. Multivariable linear regression models were used to identify predictors of DNA yield. Median DNA yield was higher for mothers in both studies compared with their children (14 μg vs. mothers or children in this analysis. The association with seasonality suggests that conditions during transport may influence DNA yield. The low yields observed in most children in these studies highlight the importance of developing alternative methods for DNA collection in younger age groups.

  8. Comparing two periphyton collection methods commonly used for stream bioassessment and the development of numeric nutrient standards.

    Science.gov (United States)

    Rodman, Ashley R; Scott, J Thad

    2017-07-01

    Periphyton is an important component of stream bioassessment, yet methods for quantifying periphyton biomass can differ substantially. A case study within the Arkansas Ozarks is presented to demonstrate the potential for linking chlorophyll-a (chl-a) and ash-free dry mass (AFDM) data sets amassed using two frequently used periphyton sampling protocols. Method A involved collecting periphyton from a known area on the top surface of variably sized rocks gathered from relatively swift-velocity riffles without discerning canopy cover. Method B involved collecting periphyton from the entire top surface of cobbles systematically gathered from riffle-run habitat where canopy cover was intentionally avoided. Chl-a and AFDM measurements were not different between methods (p = 0.123 and p = 0.550, respectively), and there was no interaction between method and time in the repeated measures structure of the study. However, significantly different seasonal distinctions were observed for chl-a and AFDM from all streams when data from the methods were combined (p methods may effectively be used together with some minor considerations due to potential confounding factors. This study provides motivation for the continued investigation of combining data sets derived from multiple methods of data collection, which could be useful in stream bioassessment and particularly important for the development of regional stream nutrient criteria for the southern Ozarks.

  9. Sea Ice as a Sink for CO2 and Biogeochemical Material: a Novel Sampling Method and Astrobiological Applications

    Science.gov (United States)

    Wilner, J.; Hofmann, A.; Hand, K. P.

    2017-12-01

    Accurately modelling the intensification of greenhouse gas effects in the polar regions ("polar amplification") necessitates a thorough understanding of the geochemical balance between atmospheric, sea ice, and oceanic layers. Sea ice is highly permeable to CO2 and therefore represents a major sink of oceanic CO2 in winter and of atmospheric CO2 in summer, sinks that are typically either poorly constrained in or fully absent from global climate models. We present a novel method for sampling both trapped and dissolved gases (CO2, CH4 and δ13CH4) in sea ice with a Picarro 2132-i Methane Analyzer, taking the following sampling considerations into account: minimization of water and air contamination, full headspace sampling, prevention of inadvertent sample bag double-puncturing, and ease of use. This method involves melting of vacuum-sealed ice cores to evacuate trapped gases to the headspace and sampling the headspace gas with a blunt needle sheathed by a beveled puncturing needle. A gravity catchment tube prevents input of dangerous levels of liquid water to the Picarro cavity. Subsequent ultrasonic degassing allows for dissolved gas measurement. We are in the process of using this method to sample gases trapped and dissolved in Arctic autumn sea ice cores and atmospheric samples collected during the 2016 Polarstern Expedition and during a May 2017 field campaign north of Barrow, Alaska. We additionally employ this method, together with inductively coupled plasma mass spectrometry (ICP-MS), to analyze the transfer of potential biogeochemical signatures of underlying hydrothermal plumes to sea ice. This has particular relevance to Europa and Enceladus, where hypothetical hydrothermal plumes may deliver seafloor chemicals to the overlying ice shell. Hence, we are presently investigating the entrainment of methane and other hydrothermal material in sea ice cores collected along the Gakkel Ridge that may serve as biosignatures of methanogenic organisms in seafloor

  10. Validation of single-sample doubly labeled water method

    International Nuclear Information System (INIS)

    Webster, M.D.; Weathers, W.W.

    1989-01-01

    We have experimentally validated a single-sample variant of the doubly labeled water method for measuring metabolic rate and water turnover in a very small passerine bird, the verdin (Auriparus flaviceps). We measured CO 2 production using the Haldane gravimetric technique and compared these values with estimates derived from isotopic data. Doubly labeled water results based on the one-sample calculations differed from Haldane values by less than 0.5% on average (range -8.3 to 11.2%, n = 9). Water flux computed by the single-sample method differed by -1.5% on average from results for the same birds based on the standard, two-sample technique (range -13.7 to 2.0%, n = 9)

  11. Reconciling PM10 analyses by different sampling methods for Iron King Mine tailings dust.

    Science.gov (United States)

    Li, Xu; Félix, Omar I; Gonzales, Patricia; Sáez, Avelino Eduardo; Ela, Wendell P

    2016-03-01

    The overall project objective at the Iron King Mine Superfund site is to determine the level and potential risk associated with heavy metal exposure of the proximate population emanating from the site's tailings pile. To provide sufficient size-fractioned dust for multi-discipline research studies, a dust generator was built and is now being used to generate size-fractioned dust samples for toxicity investigations using in vitro cell culture and animal exposure experiments as well as studies on geochemical characterization and bioassay solubilization with simulated lung and gastric fluid extractants. The objective of this study is to provide a robust method for source identification by comparing the tailing sample produced by dust generator and that collected by MOUDI sampler. As and Pb concentrations of the PM10 fraction in the MOUDI sample were much lower than in tailing samples produced by the dust generator, indicating a dilution of Iron King tailing dust by dust from other sources. For source apportionment purposes, single element concentration method was used based on the assumption that the PM10 fraction comes from a background source plus the Iron King tailing source. The method's conclusion that nearly all arsenic and lead in the PM10 dust fraction originated from the tailings substantiates our previous Pb and Sr isotope study conclusion. As and Pb showed a similar mass fraction from Iron King for all sites suggesting that As and Pb have the same major emission source. Further validation of this simple source apportionment method is needed based on other elements and sites.

  12. Sample Size Calculations for Population Size Estimation Studies Using Multiplier Methods With Respondent-Driven Sampling Surveys.

    Science.gov (United States)

    Fearon, Elizabeth; Chabata, Sungai T; Thompson, Jennifer A; Cowan, Frances M; Hargreaves, James R

    2017-09-14

    While guidance exists for obtaining population size estimates using multiplier methods with respondent-driven sampling surveys, we lack specific guidance for making sample size decisions. To guide the design of multiplier method population size estimation studies using respondent-driven sampling surveys to reduce the random error around the estimate obtained. The population size estimate is obtained by dividing the number of individuals receiving a service or the number of unique objects distributed (M) by the proportion of individuals in a representative survey who report receipt of the service or object (P). We have developed an approach to sample size calculation, interpreting methods to estimate the variance around estimates obtained using multiplier methods in conjunction with research into design effects and respondent-driven sampling. We describe an application to estimate the number of female sex workers in Harare, Zimbabwe. There is high variance in estimates. Random error around the size estimate reflects uncertainty from M and P, particularly when the estimate of P in the respondent-driven sampling survey is low. As expected, sample size requirements are higher when the design effect of the survey is assumed to be greater. We suggest a method for investigating the effects of sample size on the precision of a population size estimate obtained using multipler methods and respondent-driven sampling. Uncertainty in the size estimate is high, particularly when P is small, so balancing against other potential sources of bias, we advise researchers to consider longer service attendance reference periods and to distribute more unique objects, which is likely to result in a higher estimate of P in the respondent-driven sampling survey. ©Elizabeth Fearon, Sungai T Chabata, Jennifer A Thompson, Frances M Cowan, James R Hargreaves. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 14.09.2017.

  13. Sampling and Analytical Method for Alpha-Dicarbonyl Flavoring Compounds via Derivatization with o-Phenylenediamine and Analysis Using GC-NPD

    Directory of Open Access Journals (Sweden)

    Stephanie M. Pendergrass

    2016-01-01

    Full Text Available A novel methodology is described for the sampling and analysis of diacetyl, 2,3-pentanedione, 2,3-hexanedione, and 2,3-heptanedione. These analytes were collected on o-phenylenediamine-treated silica gel tubes and quantitatively recovered as the corresponding quinoxaline derivatives. After derivatization, the sorbent was desorbed in 3 mL of ethanol solvent and analyzed using gas chromatography/nitrogen-phosphorous detection (GC/NPD. The limits of detection (LOD achieved for each analyte were determined to be in the range of 5–10 nanograms/sample. Evaluation of the on-tube derivatization procedure indicated that it is unaffected by humidities ranging from 20% to 80% and that the derivatization procedure was quantitative for analyte concentrations ranging from 0.1 μg to approximately 500 μg per sample. Storage stability studies indicated that the derivatives were stable for 30 days when stored at both ambient and refrigerated temperatures. Additional studies showed that the quinoxaline derivatives were quantitatively recovered when sampling up to a total volume of 72 L at a sampling rate of 50 cc/min. This method will be important to evaluate and monitor worker exposures in the food and flavoring industry. Samples can be collected over an 8-hour shift with up to 288 L total volume collected regardless of time, sampling rate, and/or the effects of humidity.

  14. Miniature Blimps for Surveillance and Collection of Samples

    Science.gov (United States)

    Jones, Jack

    2004-01-01

    Miniature blimps are under development as robots for use in exploring the thick, cold, nitrogen atmosphere of Saturn's moon, Titan. Similar blimps can also be used for surveillance and collection of biochemical samples in buildings, caves, subways, and other, similar structures on Earth. The widely perceived need for means to thwart attacks on buildings and to mitigate the effects of such attacks has prompted consideration of the use of robots. Relative to rover-type (wheeled) robots that have been considered for such uses, miniature blimps offer the advantage of ability to move through the air in any direction and, hence, to perform tasks that are difficult or impossible for wheeled robots, including climbing stairs and looking through windows. In addition, miniature blimps are expected to have greater range and to cost less, relative to wheeled robots.

  15. Sample handling and contamination encountered when coupling offline normal phase high performance liquid chromatography fraction collection of petroleum samples to Fourier transform ion cyclotron resonance mass spectrometry.

    Science.gov (United States)

    Oro, Nicole E; Whittal, Randy M; Lucy, Charles A

    2012-09-05

    Normal phase high performance liquid chromatography (HPLC) is used to separate a gas oil petroleum sample, and the fractions are collected offline and analyzed on a high resolution Fourier Transform Ion Cyclotron Resonance Mass Spectrometer (FT-ICR MS). The separation prior to MS analysis dilutes the sample significantly; therefore the fractions need to be prepared properly to achieve the best signal possible. The methods used to prepare the HPLC fractions for MS analysis are described, with emphasis placed on increasing the concentration of analyte species. The dilution effect also means that contamination in the MS spectra needs to be minimized. The contamination from molecular sieves, plastics, soap, etc. and interferences encountered during the offline fraction collection process are described and eliminated. A previously unreported MS contamination of iron formate clusters with a 0.8 mass defect in positive mode electrospray is also described. This interference resulted from the stainless steel tubing in the HPLC system. Contamination resulting from what has tentatively been assigned as palmitoylglycerol and stearoylglycerol was also observed; these compounds have not previously been reported as contaminant peaks. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. 77 FR 72361 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2012-12-05

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential... Qualitative Feedback on Agency Service Delivery SUMMARY: As part of a Federal Government-wide effort to... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  17. 78 FR 23755 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2013-04-22

    ... justify the proposed sample size, the expected response rate, methods for assessing potential non-response... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Qualitative Feedback on Agency Service Delivery '' for approval under the Paperwork Reduction Act (PRA) (44 U...

  18. 76 FR 12072 - Guidance for Agency Information Collection Activities: Proposed Collection; Comment Request...

    Science.gov (United States)

    2011-03-04

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Activities: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative... Qualitative Feedback on Agency Service Delivery'' for approval under the Paperwork Reduction Act (PRA) (44 U.S...

  19. 76 FR 44938 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-07-27

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential... Qualitative Feedback on Agency Service Delivery: National Cancer Center (NCI) ACTION: 30-Day notice of... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  20. 76 FR 22920 - Agency Information Collection Activities: Proposed Collection; Comment Request; DOL Generic...

    Science.gov (United States)

    2011-04-25

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Collection; Comment Request; DOL Generic Clearance for the Collection of Qualitative Feedback on Agency... of Qualitative Feedback on Agency Service Delivery'' to the Office of Management and Budget (OMB) for...

  1. New methods for field collection of human skin volatiles and perspectives for their application in the chemical ecology of human-pathogen-vector interactions.

    Science.gov (United States)

    Dormont, Laurent; Bessière, Jean-Marie; McKey, Doyle; Cohuet, Anna

    2013-08-01

    Odours emitted by human skin are of great interest to biologists in many fields, with practical applications in forensics, health diagnostic tools and the ecology of blood-sucking insect vectors of human disease. Convenient methods are required for sampling human skin volatiles under field conditions. We experimentally compared four modern methods for sampling skin odours: solvent extraction, headspace solid-phase micro-extraction (SPME), and two new techniques not previously used for the study of mammal volatiles, contact SPME and dynamic headspace with a chromatoprobe design. These methods were tested and compared both on European subjects under laboratory conditions and on young African subjects under field conditions. All four methods permitted effective trapping of skin odours, including the major known human skin volatile compounds. In both laboratory and field experiments, contact SPME, in which the time of collection was restricted to 3 min, provided results very similar to those obtained with classical headspace SPME, a method that requires 45 min of collection. Chromatoprobe sampling also proved to be very sensitive, rapid and convenient for the collection of human-produced volatiles in natural settings. Both contact SPME and chromatoprobe design may considerably facilitate the study of human skin volatiles under field conditions, opening new possibilities for examining the olfactory cues mediating the host-seeking behaviour of mosquito vectors implicated in the transmission of major diseases.

  2. Collection, pre-treatment and analyses of Cs-137 and Tc-99 in marine samples at the Institute of Marine Research (IMR), Norway

    International Nuclear Information System (INIS)

    Heldal, H.E.

    2010-01-01

    ]-impregnated filters and a flow-meter are mounted in a series directly on the ships water intake. About 200 L seawater are passed through the filters at a flow rate of 5 L/min. The filters are then dried at 60 deg. C for about 24 h and brought back to IMR where they are ashed at 450 deg. C and filled into 60 ml polyethylene counting boxes prior to analysis. Samples from the CTD-rosette multi-bottle sampler are shipped back to the laboratory and analysed using the ammonium molybdophosphate (AMP)-method. Biota, seawater and sediment samples are gamma-counted on Ortec HPGe-detectors with efficiencies ranging from 30 to 60 %, electric cryostat cooling systems, and 10 cm lead shieldings. For the analysis of Tc-99, 50-100 L of seawater is collected from the shipboard pump (surface samples) or CTD-rosette multi-bottle sampler (samples from the water column) and filled into 25 L polyethylene carboys. A known amount of rhenium (Re) is added to each sample as a carrier and yield monitor on board the ship. Further, the samples are passed through anion exchange resins made of BioRad AGx8 (100-200 mesh) packed into 60 ml disposable polystyrene syringes. The syringes containing the anion exchange resin are brought back to IMR for further radiochemical treatment. A RISOe beta-counter is used for beta-counting for Tc-99. Information about salinity and temperature of the seawater is normally available from the stations we collect samples. This information is important while interpreting the results. Samples of biota and sediments are collected for analysis of different hydrocarbons and persistent organic pollutants (POPs) from the same stations as the radionuclide samples. Combining these results gives us a more overall picture of the pollution load. (author)

  3. Comparison of Pectin Hydrogel Collection Methods in Microfluidic Device

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chaeyeon; Park, Ki-Su; Kang, Sung-Min; Kim, Jongmin; Song, YoungShin; Lee, Chang-Soo [Chungnam National University, Daejeon (Korea, Republic of)

    2015-12-15

    This study investigated the effect of different collection methods on physical properties of pectin hydrogels in microfluidic synthetic approach. The pectin hydrogels were simply produced by the incorporation of calcium ions dissolved in continuous mineral oil. Then, different collection methods, pipetting, tubing, and settling, for harvesting pectin hydrogels were applied. The settling method showed most uniform and monodispersed hydrogels. In the case of settling, a coefficient of variation was 3.46 which was lower than pipetting method (18.60) and tubing method (14.76). Under the settling method, we could control the size of hydrogels, ranging from 30 μm to 180 μm, by simple manipulation of the viscosity of pectin and volumetric flow rate of dispersed and continuous phase. Finally, according to the characteristics of simple encapsulation of biological materials, we envision that the pectin hydrogels can be applied to drug delivery, food, and biocompatible materials.

  4. Comparison of three media for transport and storage of the samples collected for detection of avian influenza virus.

    Science.gov (United States)

    Zhang, Xiao-Chun; Liu, Shuo; Hou, Guang-Yu; Zhuang, Qing-Ye; Wang, Kai-Cheng; Jiang, Wen-Ming; Wang, Su-Chun; Li, Jin-Ping; Yu, Jian-Min; Du, Xiang; Huang, Bao-Xu; Chen, Ji-Ming

    2015-09-15

    Detection of avian influenza viruses (AIVs) is important for diagnosis, surveillance and control of avian influenza which is of great economic and public health significance. Proper transport and storage of samples is critical for the detection when the samples cannot be detected immediately. As recommended by some international or national authoritative entities and some publications, phosphate buffered saline (PBS), PBS-glycerol and brain heart infusion broth (BHIB) are frequently used for transport and storage of the samples collected for detection of AIVs worldwide. In this study, we compared these three media for transport and storage of simulated and authentic swab and feces samples collected for detection of AIVs using virus isolation and reverse transcription-PCR. The results suggest that PBS-glycerol is superior to PBS and BHIB as the sample transport and storage media. The results also suggest that the samples collected for detection of AIVs should be detected as soon as possible because the virus concentration of the samples may decline rapidly during storage within days at 4 or -20°C. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Theorical and practical bases for blood sample collection from the heel of newborns for neonatal screening

    Directory of Open Access Journals (Sweden)

    Marcela Vela-Amieva

    2014-07-01

    collected in a special filter paper (Guthrie’s card. Despite its apparent simplicity, NBS laboratories commonly receive a large number of samples collected incorrectly and technically unsuitable for perfor4ming biochemical determinations. The aim of the present paper is to offer recommendations based on scientific evidence, for the properly blood collection on filter paper for NBS programs.

  6. Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories.

    Science.gov (United States)

    Wallin, Olof; Söderberg, Johan; Van Guelpen, Bethany; Stenlund, Hans; Grankvist, Kjell; Brulin, Christine

    2010-09-01

    Scand J Caring Sci; 2010; 24; 581-591 
 Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories   Most errors in venous blood testing result from human mistakes occurring before the sample reach the laboratory.   To survey venous blood sampling (VBS) practices in hospital wards and to compare practices with hospital laboratories.   Staff in two hospitals (all wards) and two hospital laboratories (314 respondents, response rate 94%), completed a questionnaire addressing issues relevant to the collection of venous blood samples for clinical chemistry testing.   The findings suggest that instructions for patient identification and the collection of venous blood samples were not always followed. For example, 79% of the respondents reported the undesirable practice (UDP) of not always using wristbands for patient identification. Similarly, 87% of the respondents noted the UDP of removing venous stasis after the sampling is finished. Compared with the ward staff, a significantly higher proportion of the laboratory staff reported desirable practices regarding the collection of venous blood samples. Neither education nor the existence of established sampling routines was clearly associated with VBS practices among the ward staff.   The results of this study, the first of its kind, suggest that a clinically important risk of error is associated with VBS in the surveyed wards. Most important is the risk of misidentification of patients. Quality improvement of blood sample collection is clearly needed, particularly in hospital wards. © 2009 The Authors. Journal compilation © 2009 Nordic College of Caring Science.

  7. Salivary Cortisol as a Biomarker of Stress in Mothers and their Low Birth Weight Infants and Sample Collecting Challenges

    Directory of Open Access Journals (Sweden)

    Janevski Milica Ranković

    2016-04-01

    Full Text Available Background: Salivary cortisol measurement is a non-invasive method suitable for use in neonatal research. Mother-infant separation after birth represents stress and skin-to-skin contact (SSC has numerous benefits. The aim of the study was to measure salivary cortisol in mothers and newborns before and after SSC in order to assess the effect of SSC on mothers’ and infants’ stress and to estimate the efficacy of collecting small saliva samples in newborns.

  8. A Preliminary Study on Sensitivity and Uncertainty Analysis with Statistic Method: Uncertainty Analysis with Cross Section Sampling from Lognormal Distribution

    Energy Technology Data Exchange (ETDEWEB)

    Song, Myung Sub; Kim, Song Hyun; Kim, Jong Kyung [Hanyang Univ., Seoul (Korea, Republic of); Noh, Jae Man [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    The uncertainty evaluation with statistical method is performed by repetition of transport calculation with sampling the directly perturbed nuclear data. Hence, the reliable uncertainty result can be obtained by analyzing the results of the numerous transport calculations. One of the problems in the uncertainty analysis with the statistical approach is known as that the cross section sampling from the normal (Gaussian) distribution with relatively large standard deviation leads to the sampling error of the cross sections such as the sampling of the negative cross section. Some collection methods are noted; however, the methods can distort the distribution of the sampled cross sections. In this study, a sampling method of the nuclear data is proposed by using lognormal distribution. After that, the criticality calculations with sampled nuclear data are performed and the results are compared with that from the normal distribution which is conventionally used in the previous studies. In this study, the statistical sampling method of the cross section with the lognormal distribution was proposed to increase the sampling accuracy without negative sampling error. Also, a stochastic cross section sampling and writing program was developed. For the sensitivity and uncertainty analysis, the cross section sampling was pursued with the normal and lognormal distribution. The uncertainties, which are caused by covariance of (n,.) cross sections, were evaluated by solving GODIVA problem. The results show that the sampling method with lognormal distribution can efficiently solve the negative sampling problem referred in the previous studies. It is expected that this study will contribute to increase the accuracy of the sampling-based uncertainty analysis.

  9. A Preliminary Study on Sensitivity and Uncertainty Analysis with Statistic Method: Uncertainty Analysis with Cross Section Sampling from Lognormal Distribution

    International Nuclear Information System (INIS)

    Song, Myung Sub; Kim, Song Hyun; Kim, Jong Kyung; Noh, Jae Man

    2013-01-01

    The uncertainty evaluation with statistical method is performed by repetition of transport calculation with sampling the directly perturbed nuclear data. Hence, the reliable uncertainty result can be obtained by analyzing the results of the numerous transport calculations. One of the problems in the uncertainty analysis with the statistical approach is known as that the cross section sampling from the normal (Gaussian) distribution with relatively large standard deviation leads to the sampling error of the cross sections such as the sampling of the negative cross section. Some collection methods are noted; however, the methods can distort the distribution of the sampled cross sections. In this study, a sampling method of the nuclear data is proposed by using lognormal distribution. After that, the criticality calculations with sampled nuclear data are performed and the results are compared with that from the normal distribution which is conventionally used in the previous studies. In this study, the statistical sampling method of the cross section with the lognormal distribution was proposed to increase the sampling accuracy without negative sampling error. Also, a stochastic cross section sampling and writing program was developed. For the sensitivity and uncertainty analysis, the cross section sampling was pursued with the normal and lognormal distribution. The uncertainties, which are caused by covariance of (n,.) cross sections, were evaluated by solving GODIVA problem. The results show that the sampling method with lognormal distribution can efficiently solve the negative sampling problem referred in the previous studies. It is expected that this study will contribute to increase the accuracy of the sampling-based uncertainty analysis

  10. Standard methods for sampling North American freshwater fishes

    Science.gov (United States)

    Bonar, Scott A.; Hubert, Wayne A.; Willis, David W.

    2009-01-01

    This important reference book provides standard sampling methods recommended by the American Fisheries Society for assessing and monitoring freshwater fish populations in North America. Methods apply to ponds, reservoirs, natural lakes, and streams and rivers containing cold and warmwater fishes. Range-wide and eco-regional averages for indices of abundance, population structure, and condition for individual species are supplied to facilitate comparisons of standard data among populations. Provides information on converting nonstandard to standard data, statistical and database procedures for analyzing and storing standard data, and methods to prevent transfer of invasive species while sampling.

  11. Determination of multi-element in marine sediment samples collected in Angola by the k0-NAA technique

    International Nuclear Information System (INIS)

    Teixeira, M.C.P.; Ho Manh Dung; Cao Dong Vu; Nguyen Thi Sy; Nguyen Thanh Binh; Vuong Huu Tan

    2006-01-01

    The marine sediment samples were designed to collect in Angola for marine environmental pollution study. The k 0 -standardization method of neutron activation analysis (k 0 -NAA) on Dalat research reactor has been developed to determine of multi-element in the Angola marine sediment samples. The samples were irradiated in cell 7-1 for short- and middle-lived nuclides and rotary specimen rack for long-lived nuclides. The irradiation facilities were characterized for neutron spectrum parameters and post-activated samples were measured on the calibrated gamma-ray spectrometers using HPGe detectors. The analytical results for 9 marine sediment samples with 27 elements: Al, As, Br, Ca, Ce,Cl, Co, Cs, Dy, Fe, Hf, I, K, Mg, Mn, Na, Rb, Sb, Sc, Se, Sm, Th, Ti, U, V and Zn in term of mean concentration, standard deviation and their content range are shown in the report. The analytical quality assurance was done by analysis of a Japan's certified reference material namely marine sediment NMIJ-CRM-7302a. These preliminary results revealed that the k 0 -NAA technique on the Dalat research reactor is a good analytical technique for determination of multi-element in the marine sediment samples. Some heavy metals and trace elements determined in this work possibly connected to the human activities at the sampling region. (author)

  12. Collecting Samples for Testing

    Science.gov (United States)

    ... Creatinine Ratio Valproic Acid Vancomycin Vanillylmandelic Acid (VMA) VAP Vitamin A Vitamin B12 and Folate Vitamin D ... that used for CSF in that they require aspiration of a sample of the fluid through a ...

  13. 76 FR 20967 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-04-14

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: U... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under...

  14. 78 FR 44099 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2013-07-23

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Qualitative Feedback on Agency Service Delivery'' for approval under the Paperwork Reduction Act (PRA) (44 U.S...

  15. Effect of seed collection times and pretreatment methods on ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-08-18

    Aug 18, 2008 ... Seeds were subjected to four treatment methods each at four ... were deep-green to brown while second collection was done when all .... discarded and the intact plump seeds were surface sterilized with .... Analysis of variance table for cumulative germination of Terminalia sericea for first seed collection.

  16. Persistent organic pollutants in biota samples collected during the Ymer-80 expedition to the Arctic

    Directory of Open Access Journals (Sweden)

    Henrik Kylin

    2015-10-01

    Full Text Available During the 1980 expedition to the Arctic with the icebreaker Ymer, a number of vertebrate species were sampled for determination of persistent organic pollutants. Samples of Arctic char (Salvelinus alpinus, n=34, glaucous gull (Larus hyperboreus, n=8, common eider (Somateria mollissima, n=10, Brünnich's guillemot (Uria lomvia, n=9, ringed seal (Pusa hispida, n=2 and polar bear (Ursus maritimus, n=2 were collected. With the exception of Brünnich's guillemot, there was a marked contamination difference of birds from western as compared to eastern/northern Svalbard. Samples in the west contained a larger number of polychlorinated biphenyl (PCB congeners and also polychlorinated terphenyls, indicating local sources. Brünnich's guillemots had similar pollutant concentrations in the west and east/north; possibly younger birds were sampled in the west. In Arctic char, pollutant profiles from lake Linnévatn (n=5, the lake closest to the main economic activities in Svalbard, were similar to profiles in Arctic char from the Shetland Islands (n=5, but differed from lakes to the north and east in Svalbard (n=30. Arctic char samples had higher concentrations of hexachlorocyclohexanes (HCHs than the marine species of birds and mammals, possibly due to accumulation via snowmelt. Compared to the Baltic Sea, comparable species collected in Svalbard had lower concentrations of PCB and dichlorodiphenyltrichloroethane (DDT, but similar concentrations indicating long-range transport of hexachlorobenzene, HCHs and cyclodiene pesticides. In samples collected in Svalbard in 1971, the concentrations of PCB and DDT in Brünnich's guillemot (n=7, glaucous gull (n=2 and polar bear (n=2 were similar to the concentrations found in 1980.

  17. Liquid-phase sample preparation method for real-time monitoring of airborne asbestos fibers by dual-mode high-throughput microscopy.

    Science.gov (United States)

    Cho, Myoung-Ock; Kim, Jung Kyung; Han, Hwataik; Lee, Jeonghoon

    2013-01-01

    Asbestos that had been used widely as a construction material is a first-level carcinogen recognized by the World Health Organization. It can be accumulated in body by inhalation causing virulent respiratory diseases including lung cancer. In our previous study, we developed a high-throughput microscopy (HTM) system that can minimize human intervention accompanied by the conventional phase contrast microscopy (PCM) through automated counting of fibrous materials and thus significantly reduce analysis time and labor. Also, we attempted selective detection of chrysotile using DksA protein extracted from Escherichia coli through a recombinant protein production technique, and developed a dual-mode HTM (DM-HTM) by upgrading the HTM device. We demonstrated that fluorescently-labeled chrysotile asbestos fibers can be identified and enumerated automatically among other types of asbestos fibers or non-asbestos particles in a high-throughput manner through a newly modified HTM system for both reflection and fluorescence imaging. However there is a limitation to apply DM-HTM to airborne sample with current air collecting method due to the difficulty of applying the protein to dried asbestos sample. Here, we developed a technique for preparing liquid-phase asbestos sample using an impinger normally used to collect odor molecules in the air. It would be possible to improve the feasibility of the dual-mode HTM by integrating a sample preparation unit for making collected asbestos sample dispersed in a solution. The new technique developed for highly sensitive and automated asbestos detection can be a potential alternative to the conventional manual counting method, and it may be applied on site as a fast and reliable environmental monitoring tool.

  18. Passive sampling methods for contaminated sediments

    DEFF Research Database (Denmark)

    Peijnenburg, Willie J.G.M.; Teasdale, Peter R.; Reible, Danny

    2014-01-01

    “Dissolved” concentrations of contaminants in sediment porewater (Cfree) provide a more relevant exposure metric for risk assessment than do total concentrations. Passive sampling methods (PSMs) for estimating Cfree offer the potential for cost-efficient and accurate in situ characterization...

  19. [Sampling methods for PM2.5 from stationary sources: a review].

    Science.gov (United States)

    Jiang, Jing-Kun; Deng, Jian-Guo; Li, Zhen; Li, Xing-Hua; Duan, Lei; Hao, Ji-Ming

    2014-05-01

    The new China national ambient air quality standard has been published in 2012 and will be implemented in 2016. To meet the requirements in this new standard, monitoring and controlling PM2,,5 emission from stationary sources are very important. However, so far there is no national standard method on sampling PM2.5 from stationary sources. Different sampling methods for PM2.5 from stationary sources and relevant international standards were reviewed in this study. It includes the methods for PM2.5 sampling in flue gas and the methods for PM2.5 sampling after dilution. Both advantages and disadvantages of these sampling methods were discussed. For environmental management, the method for PM2.5 sampling in flue gas such as impactor and virtual impactor was suggested as a standard to determine filterable PM2.5. To evaluate environmental and health effects of PM2.5 from stationary sources, standard dilution method for sampling of total PM2.5 should be established.

  20. Materials and Methods for Streamlined Laboratory Analysis of Environmental Samples, FY 2016 Report

    Energy Technology Data Exchange (ETDEWEB)

    Addleman, Raymond S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Naes, Benjamin E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McNamara, Bruce K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Olsen, Khris B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chouyyok, Wilaiwan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Willingham, David G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Spigner, Angel C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-11-30

    The International Atomic Energy Agency (IAEA) relies upon laboratory analysis of environmental samples (typically referred to as “swipes”) collected during on-site inspections of safeguarded facilities to support the detection and deterrence of undeclared activities. Unfortunately, chemical processing and assay of the samples is slow and expensive. A rapid, effective, and simple extraction process and analysis method is needed to provide certified results with improved timeliness at reduced costs (principally in the form of reduced labor), while maintaining or improving sensitivity and efficacy. To address these safeguard needs the Pacific Northwest National Laboratory (PNNL) explored and demonstrated improved methods for environmental sample (ES) analysis. Improvements for both bulk and particle analysis were explored. To facilitate continuity and adoption, the new sampling materials and processing methods will be compatible with existing IAEA protocols for ES analysis. PNNL collaborated with Oak Ridge National Laboratory (ORNL), which performed independent validation of the new bulk analysis methods and compared performance to traditional IAEA’s Network of Analytical Laboratories (NWAL) protocol. ORNL efforts are reported separately. This report describes PNNL’s FY 2016 progress, which was focused on analytical application supporting environmental monitoring of uranium enrichment plants and nuclear fuel processing. In the future the technology could be applied to other safeguard applications and analytes related to fuel manufacturing, reprocessing, etc. PNNL’s FY 2016 efforts were broken into two tasks and a summary of progress, accomplishments and highlights are provided below. Principal progress and accomplishments on Task 1, Optimize Materials and Methods for ICP-MS Environmental Sample Analysis, are listed below. • Completed initial procedure for rapid uranium extraction from ES swipes based upon carbonate-peroxide chemistry (delivered to ORNL for

  1. Approximation of the exponential integral (well function) using sampling methods

    Science.gov (United States)

    Baalousha, Husam Musa

    2015-04-01

    Exponential integral (also known as well function) is often used in hydrogeology to solve Theis and Hantush equations. Many methods have been developed to approximate the exponential integral. Most of these methods are based on numerical approximations and are valid for a certain range of the argument value. This paper presents a new approach to approximate the exponential integral. The new approach is based on sampling methods. Three different sampling methods; Latin Hypercube Sampling (LHS), Orthogonal Array (OA), and Orthogonal Array-based Latin Hypercube (OA-LH) have been used to approximate the function. Different argument values, covering a wide range, have been used. The results of sampling methods were compared with results obtained by Mathematica software, which was used as a benchmark. All three sampling methods converge to the result obtained by Mathematica, at different rates. It was found that the orthogonal array (OA) method has the fastest convergence rate compared with LHS and OA-LH. The root mean square error RMSE of OA was in the order of 1E-08. This method can be used with any argument value, and can be used to solve other integrals in hydrogeology such as the leaky aquifer integral.

  2. Establishment of a cervical cancer bio-bank for the Chinese population: from project-based sample collection to routine management.

    Science.gov (United States)

    Yang, Ru; Li, Xiong; Zhou, Hang; Jia, Yao; Zhou, Jin; Huang, Kecheng; Tang, Fangxu; Hu, Ting; Shen, Jian; Chen, Zhilan; Wang, Shaoshuai; Sun, Haiying; Guo, Lili; Wang, Lin; Wang, Hui; Ma, Ding; Li, Shuang

    2015-08-01

    There is an increasing need for the establishment of a cervical cancer bio-bank that will facilitate both clinical and basic research. The cervical cancer bio-bank was first established in January 1999 and included two stages. First, a GWAS-based sample collection was conducted with special emphasis on the diagnosis and the retrieval of the corresponding bio-specimens, especially blood samples. Second, clinical data and their corresponding bio-specimens were routinely collected and handled. Notably, these bio-specimens also included samples from Wufeng Tujia Autonomous County, which has the highest incidence of cervical cancer in China. The specimens were collected from patients with cervical cancer and those with cervical intraepithelial neoplasia, while the control samples were collected from normal individuals. With special emphasis on clinical data and blood samples for the GWAS analysis, the collection of other bio-specimens was slow, and the pairing of specimens and clinical data was poor during the first stage. However, in the second stage, the pairing of the clinical data and its corresponding bio-specimens improved. At present, the samples procured and preserved in the bio-bank cover most regions of China and different ethnic groups for both the normal controls and cervical cancer patients of different pathological categories. This bio-bank of cervical cancer specimens from the Chinese population will greatly promote the studies of cervical cancer in China.

  3. Untargeted metabolomic profiling plasma samples of patients with lung cancer for searching significant metabolites by HPLC-MS method

    Science.gov (United States)

    Dementeva, N.; Ivanova, K.; Kokova, D.; Kurzina, I.; Ponomaryova, A.; Kzhyshkowska, J.

    2017-09-01

    Lung cancer is one of the most common types of cancer leading to death. Consequently, the search and the identification of the metabolites associated with the risk of developing cancer are very valuable. For the purpose, untargeted metabolic profiling of the plasma samples collected from the patients with lung cancer (n = 100) and the control group (n = 100) was conducted. After sample preparation, the plasma samples were analyzed using LC-MS method. Biostatistics methods were applied to pre-process the data for elicitation of dominating metabolites which responded to the difference between the case and the control groups. At least seven significant metabolites were evaluated and annotated. The most part of identified metabolites are connected with lipid metabolism and their combination could be useful for follow-up studies of lung cancer pathogenesis.

  4. Maintenance planning support method for nuclear power plants based on collective decision making

    International Nuclear Information System (INIS)

    Shimizu, Shunichi; Sakurai, Shoji; Takaoka, Kazushi; Kanemoto, Shigeru; Fukutomi, Shigeki

    1992-01-01

    Inspection and maintenance planning in nuclear power plants is conducted by decision making based on experts' collective consensus. However, since a great deal of time and effort is required to reach a consensus among expert judgments, the establishment of effective decision making methods is necessary. Therefore, the authors developed a method for supporting collective decision making, based on a combination of three types of decision making methods; the Characteristic Diagram method, Interpretative Structural Modeling method, and the Analytic Hierarchy Process method. The proposed method enables us to determine the evaluation criteria systematically for collective decision making, and also allows extracting collective decisions using simplified questionnaires. The proposed method can support reaching a consensus of groups effectively through the evaluation of collective decision structural models and their characteristics. In this paper, the effectiveness of the proposed method was demonstrated through its application to the decision making problem concerning whether or not the improved ultrasonic testing equipment should be adopted at nuclear power plants. (author)

  5. Characterization of hazardous waste sites: a methods manual. Volume 2. Available sampling methods (second edition)

    International Nuclear Information System (INIS)

    Ford, P.J.; Turina, P.J.; Seely, D.E.

    1984-12-01

    Investigations at hazardous waste sites and sites of chemical spills often require on-site measurements and sampling activities to assess the type and extent of contamination. This document is a compilation of sampling methods and materials suitable to address most needs that arise during routine waste site and hazardous spill investigations. The sampling methods presented in this document are compiled by media, and were selected on the basis of practicality, economics, representativeness, compatability with analytical considerations, and safety, as well as other criteria. In addition to sampling procedures, sample handling and shipping, chain-of-custody procedures, instrument certification, equipment fabrication, and equipment decontamination procedures are described. Sampling methods for soil, sludges, sediments, and bulk materials cover the solids medium. Ten methods are detailed for surface waters, groundwater and containerized liquids; twelve are presented for ambient air, soil gases and vapors, and headspace gases. A brief discussion of ionizing radiation survey instruments is also provided

  6. A Practical Method for Collecting Social Media Campaign Metrics

    Science.gov (United States)

    Gharis, Laurie W.; Hightower, Mary F.

    2017-01-01

    Today's Extension professionals are tasked with more work and fewer resources. Integrating social media campaigns into outreach efforts can be an efficient way to meet work demands. If resources go toward social media, a practical method for collecting metrics is needed. Collecting metrics adds one more task to the workloads of Extension…

  7. Adaptive sampling method in deep-penetration particle transport problem

    International Nuclear Information System (INIS)

    Wang Ruihong; Ji Zhicheng; Pei Lucheng

    2012-01-01

    Deep-penetration problem has been one of the difficult problems in shielding calculation with Monte Carlo method for several decades. In this paper, a kind of particle transport random walking system under the emission point as a sampling station is built. Then, an adaptive sampling scheme is derived for better solution with the achieved information. The main advantage of the adaptive scheme is to choose the most suitable sampling number from the emission point station to obtain the minimum value of the total cost in the process of the random walk. Further, the related importance sampling method is introduced. Its main principle is to define the importance function due to the particle state and to ensure the sampling number of the emission particle is proportional to the importance function. The numerical results show that the adaptive scheme under the emission point as a station could overcome the difficulty of underestimation of the result in some degree, and the adaptive importance sampling method gets satisfied results as well. (authors)

  8. 76 FR 13019 - Agency Information Collection Activities: Comment Request; Generic Clearance for the Collection...

    Science.gov (United States)

    2011-03-09

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Department of...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...

  9. 76 FR 37825 - Agency Information Collection Activities; Generic Clearance for the Collection of Qualitative...

    Science.gov (United States)

    2011-06-28

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Activities; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: U...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...

  10. Choosing a Cluster Sampling Design for Lot Quality Assurance Sampling Surveys

    OpenAIRE

    Hund, Lauren; Bedrick, Edward J.; Pagano, Marcello

    2015-01-01

    Lot quality assurance sampling (LQAS) surveys are commonly used for monitoring and evaluation in resource-limited settings. Recently several methods have been proposed to combine LQAS with cluster sampling for more timely and cost-effective data collection. For some of these methods, the standard binomial model can be used for constructing decision rules as the clustering can be ignored. For other designs, considered here, clustering is accommodated in the design phase. In this paper, we comp...

  11. Effect of DNA extraction methods and sampling techniques on the apparent structure of cow and sheep rumen microbial communities.

    Directory of Open Access Journals (Sweden)

    Gemma Henderson

    Full Text Available Molecular microbial ecology techniques are widely used to study the composition of the rumen microbiota and to increase understanding of the roles they play. Therefore, sampling and DNA extraction methods that result in adequate yields of microbial DNA that also accurately represents the microbial community are crucial. Fifteen different methods were used to extract DNA from cow and sheep rumen samples. The DNA yield and quality, and its suitability for downstream PCR amplifications varied considerably, depending on the DNA extraction method used. DNA extracts from nine extraction methods that passed these first quality criteria were evaluated further by quantitative PCR enumeration of microbial marker loci. Absolute microbial numbers, determined on the same rumen samples, differed by more than 100-fold, depending on the DNA extraction method used. The apparent compositions of the archaeal, bacterial, ciliate protozoal, and fungal communities in identical rumen samples were assessed using 454 Titanium pyrosequencing. Significant differences in microbial community composition were observed between extraction methods, for example in the relative abundances of members of the phyla Bacteroidetes and Firmicutes. Microbial communities in parallel samples collected from cows by oral stomach-tubing or through a rumen fistula, and in liquid and solid rumen digesta fractions, were compared using one of the DNA extraction methods. Community representations were generally similar, regardless of the rumen sampling technique used, but significant differences in the abundances of some microbial taxa such as the Clostridiales and the Methanobrevibacter ruminantium clade were observed. The apparent microbial community composition differed between rumen sample fractions, and Prevotellaceae were most abundant in the liquid fraction. DNA extraction methods that involved phenol-chloroform extraction and mechanical lysis steps tended to be more comparable. However

  12. Validation of an off line solid phase extraction liquid chromatography-tandem mass spectrometry method for the determination of systemic insecticide residues in honey and pollen samples collected in apiaries from NW Spain.

    Science.gov (United States)

    García-Chao, María; Agruña, María Jesús; Flores Calvete, Gonzalo; Sakkas, Vasilis; Llompart, María; Dagnac, Thierry

    2010-07-05

    11843 standard for the following parameters: decision limit (CCalpha), detection capability (CCbeta), recovery, repeatability and reproducibility at 0.5, 1 and 1.5 folds the MRLs. Ion suppression/enhancement effects into the ion source were also assessed. The CCbeta values were included between 0.83 and 4.83 ng g(-1), well below the current MRLs. The validated method was applied to the determination of the target pesticides in 91 samples collected in colonies from 73 apiaries of NW Spain (two sampling campaigns during 2008). None of the target insecticides were detected among all the collected samples. Copyright 2010 Elsevier B.V. All rights reserved.

  13. Waste tank vapor project: Vapor characterization of Tank 241-C-103: Data report for OVS samples collected from Sample Job 7b, Parts I and II, received 5/18/94 and 5/24/94

    International Nuclear Information System (INIS)

    Clauss, T.R.; Edwards, J.A.; Fruchter, J.S.

    1994-09-01

    On 5/18/94, Westinghouse Hanford Company (WHC) delivered samples to Pacific Northwest Laboratory (PNL) that were collected from waste Tank 241-C-103 on 5/16/94. These samples were from Sample Job (SJ) 7b, Part 1. On 5/24/94, WHC delivered samples to PNL that were collected from waste Tank 241-C-103 on 5/18/94. These samples were from SJ7b, Part 2. A summary of data derived from the sampling of waste Tank 241-C-103 for gravimetric (H 2 O) and normal paraffin hydrocarbon (NPH) concentrations are shown for SJ7b. Gravimetric analysis was performed on the samples within 24 hours of receipt by PNL. The NPH concentration of 10 samples collected for Part 1 was slightly higher than the average concentration for 15 samples collected in Part 2, 812 (± 133) mg/m 3 and 659 (± 88) mg/m 3 , respectively. The higher concentrations measured in Part 1 samples may be because the samples in Part 1 were collected at a single level, 0.79 meters above the air-liquid interface. Part 2 samples were collected at three different tank levels, 0.79, 2.92, and 5.05 m above the air-liquid interface. In Part 2, the average NPH concentrations for 5 samples collected at each of three levels was similar: 697 (60) mg/m 3 at the low level, 631 (51) mg/m 3 at the mid level, and 651 (134) mg/m 3 at the high level. It is important to note that the measured tridecane to dodecane concentration remained constant in all samples collected in Parts 1 and 2. That ratio is 1.2 ± 0.05. This consistent ratio indicates that there were no random analytical biases towards either compound

  14. Soil Gas Sampling

    Science.gov (United States)

    Field Branches Quality System and Technical Procedures: This document describes general and specific procedures, methods and considerations to be used and observed when collecting soil gas samples for field screening or laboratory analysis.

  15. Collecting Comet Samples by ER-2 Aircraft: Cosmic Dust Collection During the Draconid Meteor Shower in October 2012

    Science.gov (United States)

    Bastien, Ron; Burkett, P. J.; Rodriquez, M.; Frank, D.; Gonzalez, C.; Robinson, G.-A.; Zolensky, M.; Brown, P.; Campbell-Brown, M.; Broce, S.; hide

    2014-01-01

    Many tons of dust grains, including samples of asteroids and comets, fall from space into the Earth's atmosphere each day. NASA periodically collects some of these particles from the Earth's stratosphere using sticky collectors mounted on NASA's high-flying aircraft. Sometimes, especially when the Earth experiences a known meteor shower, a special opportunity is presented to associate cosmic dust particles with a known source. NASA JSC's Cosmic Dust Collection Program has made special attempts to collect dust from particular meteor showers and asteroid families when flights can be planned well in advance. However, it has rarely been possible to make collections on very short notice. In 2012, the Draconid meteor shower presented that opportunity. The Draconid meteor shower, originating from Comet 21P/Giacobini-Zinner, has produced both outbursts and storms several times during the last century, but the 2012 event was not predicted to be much of a show. Because of these predictions, the Cosmic Dust team had not targeted a stratospheric collection effort for the Draconids, despite the fact that they have one of the slowest atmospheric entry velocities (23 km/s) of any comet shower, and thus offer significant possibilities of successful dust capture. However, radar measurements obtained by the Canadian Meteor Orbit Radar during the 2012 Draconids shower indicated a meteor storm did occur October 8 with a peak at 16:38 (+/-5 min) UTC for a total duration of approximately 2 hours.

  16. Setting health research priorities using the CHNRI method: VI. Quantitative properties of human collective opinion.

    Science.gov (United States)

    Yoshida, Sachiyo; Rudan, Igor; Cousens, Simon

    2016-06-01

    Crowdsourcing has become an increasingly important tool to address many problems - from government elections in democracies, stock market prices, to modern online tools such as TripAdvisor or Internet Movie Database (IMDB). The CHNRI method (the acronym for the Child Health and Nutrition Research Initiative) for setting health research priorities has crowdsourcing as the major component, which it uses to generate, assess and prioritize between many competing health research ideas. We conducted a series of analyses using data from a group of 91 scorers to explore the quantitative properties of their collective opinion. We were interested in the stability of their collective opinion as the sample size increases from 15 to 90. From a pool of 91 scorers who took part in a previous CHNRI exercise, we used sampling with replacement to generate multiple random samples of different size. First, for each sample generated, we identified the top 20 ranked research ideas, among 205 that were proposed and scored, and calculated the concordance with the ranking generated by the 91 original scorers. Second, we used rank correlation coefficients to compare the ranks assigned to all 205 proposed research ideas when samples of different size are used. We also analysed the original pool of 91 scorers to to look for evidence of scoring variations based on scorers' characteristics. The sample sizes investigated ranged from 15 to 90. The concordance for the top 20 scored research ideas increased with sample sizes up to about 55 experts. At this point, the median level of concordance stabilized at 15/20 top ranked questions (75%), with the interquartile range also generally stable (14-16). There was little further increase in overlap when the sample size increased from 55 to 90. When analysing the ranking of all 205 ideas, the rank correlation coefficient increased as the sample size increased, with a median correlation of 0.95 reached at the sample size of 45 experts (median of the rank

  17. Systems and methods for self-synchronized digital sampling

    Science.gov (United States)

    Samson, Jr., John R. (Inventor)

    2008-01-01

    Systems and methods for self-synchronized data sampling are provided. In one embodiment, a system for capturing synchronous data samples is provided. The system includes an analog to digital converter adapted to capture signals from one or more sensors and convert the signals into a stream of digital data samples at a sampling frequency determined by a sampling control signal; and a synchronizer coupled to the analog to digital converter and adapted to receive a rotational frequency signal from a rotating machine, wherein the synchronizer is further adapted to generate the sampling control signal, and wherein the sampling control signal is based on the rotational frequency signal.

  18. Agreement for HPV genotyping detection between self-collected specimens on a FTA cartridge and clinician-collected specimens

    Science.gov (United States)

    Guan, YaoYao; Gravitt, Patti E.; Howard, Roslyn; Eby, Yolanda J.; Wang, Shaoming; Li, Belinda; Feng, Changyan; Qiao, You-Lin; Castle, Philip E.

    2016-01-01

    The current method of transporting self-collected cervicovaginal specimen for HPV DNA testing relies on liquid based medium, which is challenging and expensive to transport. A novel, dry storage and transportation device, Whatman indicating FTA™ Elute Cartridge, avoids some of the pitfalls of liquid-based medium. This method has been shown to be comparable to liquid-based collection medium, but relative performance of self-collected (SC) and clinician-collected (CC) samples onto FTA cards has not been reported. The objective of this study is to compare the analytic performance of self- and clinician-collected samples onto FTA cartridges for the detection of carcinogenic HPV using Linear Array. There was a 91% agreement, 69% positive agreement, and kappa of 0.75 between the clinician-collected and self-collected specimens for detection of any carcinogenic HPV genotype. When the HPV results were categorized hierarchically according to cervical cancer risk, there was no difference in the distribution of the HPV results for the clinician- and self-collected specimens (p = 0.7). This study concludes that FTA elute cartridge is a promising method of specimen transport for cervical cancer screening programs considering using self-collected specimen and HPV testing. Larger studies with clinical endpoints are now needed to assess the clinical performance. PMID:23370404

  19. Radioactivity in Soil Samples Collected in Southern Serbia

    International Nuclear Information System (INIS)

    Jankovic, M.; Nikolic, J.; Pantelic, G.; Rajacic, M.; Sarap, N.; Todorovic, D.

    2013-01-01

    In the attack on the Federal Republic of Yugoslavia (the focus effect was of Kosovo and Metohija and southern Serbia) in 1999, NATO forces used ammunition containing depleted uranium. Cleaning action of depleted uranium was performed by Radiation and Environmental Protection Department of the Vinca Institute of Nuclear Science, during 2002?2007 at locations: Pljackovica, Bratoselce, Borovac and Reljan. At all locations underwent detailed dosimetric screening and decontamination was performed. Because of the loose soil, DU projectils were found to a depth of 1 m. Found missiles, contaminated soil and radioactive material has been collected and stored on radioactive waste. After cleaning the ground is leveled and another dosimetric prospecting was performed. Monitoring of radioactivity in southern Serbia included determination of gamma emitters as well as determination of gross alpha and beta activities in soil, water and plant. Sampling was carried out at Pljackovica, Borovac, Bratoselce and Reljan in July 2011. This paper presents only the results of measurement of gamma emitters in soil samples and showed the presence of natural radionuclides: 226Ra, 232Th, 40K, 235U, 238U and the produced radionuclide 137Cs (from the Chernobyl accident). Also, the ratio between the 235U and 238U is given. In order to evaluate the radiological hazard of the natural radioactivity, the radium equivalent activity, the gamma-absorbed dose rate and the external hazard index have been calculated. (author)

  20. 24 CFR 17.136 - Procedures for salary offset: methods of collection.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Procedures for salary offset: methods of collection. 17.136 Section 17.136 Housing and Urban Development Office of the Secretary... the Government Salary Offset Provisions § 17.136 Procedures for salary offset: methods of collection...