WorldWideScience

Sample records for sample acquisition devices

  1. Development of induction current acquisition device based on ARM

    Science.gov (United States)

    Ji, Yanju; Liu, Xiyang; Huang, Wanyu; Yao, Jiang; Yuan, Guiyang; Hui, Luan; Guan, Shanshan

    2018-03-01

    We design an induction current acquisition device based on ARM in order to realize high resolution and high sampling rate of acquisition for the induction current in wire-loop. Considering its characteristics of fast attenuation and small signal amplitude, we use the method of multi-path fusion for noise suppression. In the paper, the design is carried out from three aspects of analog circuit and device selection, independent power supply structure and the electromagnetic interference suppression of high frequency. DMA and ping-pong buffer, as a new data transmission technology, solves real time storage problem of massive data. The performance parameters of ARM acquisition device are tested. The comparison test of ARM acquisition device and cRIO acquisition device is performed at different time constants. The results show that it has 120dB dynamic range, 47kHz bandwidth, 96kHz sampling rate, 5μV the smallest resolution, and its average error value is not more than 4%, which proves the high accuracy and stability of the device.

  2. Sample Acquisition for Materials in Planetary Exploration (SAMPLE), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — ORBITEC proposes to analyze, design, and develop a device for autonomous lunar surface/subsurface sampling and processing applications. The Sample Acquisition for...

  3. Grasp Algorithms For Optotactile Robotic Sample Acquisition, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Robotic sample acquisition is basically grasping. Multi-finger robot sample grasping devices are controlled to securely pick up samples. While optimal grasps for...

  4. Language Acquisition without an Acquisition Device

    Science.gov (United States)

    O'Grady, William

    2012-01-01

    Most explanatory work on first and second language learning assumes the primacy of the acquisition phenomenon itself, and a good deal of work has been devoted to the search for an "acquisition device" that is specific to humans, and perhaps even to language. I will consider the possibility that this strategy is misguided and that language…

  5. Development of signal acquisition device of rotating coil measurement system

    International Nuclear Information System (INIS)

    Zhou Jianxin; Li Li; Kang Wen; Deng Chengdong; Yin Baogui; Fu Shinian

    2013-01-01

    A new rotating coil magnetic measurement system using the technical solution of the combination of a dynamic signal acquisition card and software with specific functions was developed. The acquisition device of the system successfully implemented the function of the PDI-5025 integrator. The sampling rate, the range, the accuracy and the flexibility of the system were improved. The development program of signal acquisition equipment, the realization of the acquisition function and the reliability and stability of the system were introduced. (authors)

  6. A Flexible Microcontroller-Based Data Acquisition Device

    OpenAIRE

    Hercog, Darko; Gergič, Bojan

    2014-01-01

    This paper presents a low-cost microcontroller-based data acquisition device. The key component of the presented solution is a configurable microcontroller-based device with an integrated USB transceiver and a 12-bit analogue-to-digital converter (ADC). The presented embedded DAQ device contains a preloaded program (firmware) that enables easy acquisition and generation of analogue and digital signals and data transfer between the device and the application running on a PC via USB bus. This d...

  7. A Flexible Microcontroller-Based Data Acquisition Device

    Directory of Open Access Journals (Sweden)

    Darko Hercog

    2014-06-01

    Full Text Available This paper presents a low-cost microcontroller-based data acquisition device. The key component of the presented solution is a configurable microcontroller-based device with an integrated USB transceiver and a 12-bit analogue-to-digital converter (ADC. The presented embedded DAQ device contains a preloaded program (firmware that enables easy acquisition and generation of analogue and digital signals and data transfer between the device and the application running on a PC via USB bus. This device has been developed as a USB human interface device (HID. This USB class is natively supported by most of the operating systems and therefore any installation of additional USB drivers is unnecessary. The input/output peripheral of the presented device is not static but rather flexible, and could be easily configured to customised needs without changing the firmware. When using the developed configuration utility, a majority of chip pins can be configured as analogue input, digital input/output, PWM output or one of the SPI lines. In addition, LabVIEW drivers have been developed for this device. When using the developed drivers, data acquisition and signal processing algorithms as well as graphical user interface (GUI, can easily be developed using a well-known, industry proven, block oriented LabVIEW programming environment.

  8. A flexible microcontroller-based data acquisition device.

    Science.gov (United States)

    Hercog, Darko; Gergič, Bojan

    2014-06-02

    This paper presents a low-cost microcontroller-based data acquisition device. The key component of the presented solution is a configurable microcontroller-based device with an integrated USB transceiver and a 12-bit analogue-to-digital converter (ADC). The presented embedded DAQ device contains a preloaded program (firmware) that enables easy acquisition and generation of analogue and digital signals and data transfer between the device and the application running on a PC via USB bus. This device has been developed as a USB human interface device (HID). This USB class is natively supported by most of the operating systems and therefore any installation of additional USB drivers is unnecessary. The input/output peripheral of the presented device is not static but rather flexible, and could be easily configured to customised needs without changing the firmware. When using the developed configuration utility, a majority of chip pins can be configured as analogue input, digital input/output, PWM output or one of the SPI lines. In addition, LabVIEW drivers have been developed for this device. When using the developed drivers, data acquisition and signal processing algorithms as well as graphical user interface (GUI), can easily be developed using a well-known, industry proven, block oriented LabVIEW programming environment.

  9. Data-Acquisition Systems for Fusion Devices

    NARCIS (Netherlands)

    van Haren, P. C.; Oomens, N. A.

    1993-01-01

    During the last two decades, computerized data acquisition systems (DASs) have been applied at magnetic confinement fusion devices. Present-day data acquisition is done by means of distributed computer systems and transient recorders in CAMAC systems. The development of DASs has been technology

  10. Data-acquisition system of the reversed field pinch device REPUTE-1

    International Nuclear Information System (INIS)

    Tsuzuki, N.; Aoki, H.; Shinohara, H.; Toyama, H.; Morikawa, J.

    1988-01-01

    The new, compact data-acquisition system of the reversed field pinch device, REPUTE-1, is reported. Its distinctive feature is high flexibility and easy handling. The interface between the computer and measurement devices is CAMAC. The computer and the CAMAC devices are connected to a CAMAC byte serial highway that transmits setup parameters and acquisition data. The computer carries out setup of CAMAC devices and data acquisition automatically by use of CAMAC parameters and the acquisition data base. The maintenance tools for the data base are also provided. The computer system, which consists of a ''TOSBAC DS-600,'' has been in operation for REPUTE-1 since 1985

  11. State of art data acquisition system for large volume plasma device

    International Nuclear Information System (INIS)

    Sugandhi, Ritesh; Srivastava, Pankaj; Sanyasi, Amulya Kumar; Srivastav, Prabhakar; Awasthi, Lalit Mohan; Mattoo, Shiban Krishna; Parmar, Vijay; Makadia, Keyur; Patel, Ishan; Shah, Sandeep

    2015-01-01

    The Large volume plasma device (LVPD) is a cylindrical device (ϕ = 2m, L = 3m) dedicated for carrying out investigations on plasma physics problems ranging from excitation of whistler structures to plasma turbulence especially, exploring the linear and nonlinear aspects of electron temperature gradient(ETG) driven turbulence, plasma transport over the entire cross section of LVPD. The machine operates in a pulsed mode with repetition cycle of 1 Hz and acquisition pulse length of duration of 15 ms, presently, LVPD has VXI data acquisition system but this is now in phasing out mode because of non-functioning of its various amplifier stages, expandability and unavailability of service support. The VXI system has limited capabilities to meet new experimental requirements in terms of numbers of channel (16), bit resolutions (8 bit), record length (30K points) and calibration support. Recently, integration of new acquisition system for simultaneous sampling of 40 channels of data, collected over multiple time scales with high speed is successfully demonstrated, by configuring latest available hardware and in-house developed software solutions. The operational feasibility provided by LabVIEW platform is not only for operating DAQ system but also for providing controls to various subsystems associated with the device. The new system is based on PXI express instrumentation bus and supersedes the existing VXI based data acquisition system in terms of instrumentation capabilities. This system has capability to measure 32 signals at 60 MHz sampling frequency and 8 signals with 1.25 GHz with 10 bit and 12 bit resolution capability for amplitude measurements. The PXI based system successfully addresses and demonstrate the issues concerning high channel count, high speed data streaming and multiple I/O modules synchronization. The system consists of chassis (NI 1085), 4 high sampling digitizers (NI 5105), 2 very high sampling digitizers (NI 5162), data streaming RAID drive (NI

  12. Feasibility Study of Commercial Markets for New Sample Acquisition Devices

    Science.gov (United States)

    Brady, Collin; Coyne, Jim; Bilen, Sven G.; Kisenwether, Liz; Miller, Garry; Mueller, Robert P.; Zacny, Kris

    2010-01-01

    The NASA Exploration Systems Mission Directorate (ESMD) and Penn State technology commercialization project was designed to assist in the maturation of a NASA SBIR Phase III technology. The project was funded by NASA's ESMD Education group with oversight from the Surface Systems Office at NASA Kennedy Space Center in the Engineering Directorate. Two Penn State engineering student interns managed the project with support from Honeybee Robotics and NASA Kennedy Space Center. The objective was to find an opportunity to integrate SBIR-developed Regolith Extractor and Sampling Technology as the payload for the future Lunar Lander or Rover missions. The team was able to identify two potential Google Lunar X Prize organizations with considerable interest in utilizing regolith acquisition and transfer technology.

  13. USMC Acquisition Strategies For Cots Mobile Devices in the Tactical Environment

    Science.gov (United States)

    2017-09-01

    D., & Samtani, S. (2011). On the adaptation of commercial smartphones to tactical environments. 2011 Military Communications Conference. Retrieved...acquisition strategies to support rapid adoption and integration of emerging commercial off-the-shelf (COTS) mobile devices into the tactical domain...identified and assessed acquisition strategies to support rapid adoption and integration of emerging commercial off-the-shelf (COTS) mobile devices into

  14. Data acquisition systems for fusion devices

    International Nuclear Information System (INIS)

    Van Haren, P.C.; Oomens, N.A.

    1993-01-01

    During the last two decades, computerized data acquisition systems (DASs) have been applied at magnetic confinement fusion devices. Present-day data acquisition is done by means of distributed computer systems and transient recorders in CAMAC systems. The development of DASs has been technology driven; the emphasis has been on the development of computer hardware and system software. For future DASs, challenging problems are to be solved: The DASs have to be better optimized with respect to the needs of the users. Existing bottlenecks, such as CAMAC-computer coupling or pulse file merging, need to be eliminated. Continuous or long-pulse operation will require the introduction of event abstraction in DAS design. 59 refs., 4 figs., 1 tab

  15. An Inexpensive, Open-Source USB Arduino Data Acquisition Device for Chemical Instrumentation.

    Science.gov (United States)

    Grinias, James P; Whitfield, Jason T; Guetschow, Erik D; Kennedy, Robert T

    2016-07-12

    Many research and teaching labs rely on USB data acquisition devices to collect voltage signals from instrumentation. However, these devices can be cost-prohibitive (especially when large numbers are needed for teaching labs) and require software to be developed for operation. In this article, we describe the development and use of an open-source USB data acquisition device (with 16-bit acquisition resolution) built using simple electronic components and an Arduino Uno that costs under $50. Additionally, open-source software written in Python is included so that data can be acquired using nearly any PC or Mac computer with a simple USB connection. Use of the device was demonstrated for a sophomore-level analytical experiment using GC and a CE-UV separation on an instrument used for research purposes.

  16. High velocity pulse biopsy device enables controllable and precise needle insertion and high yield tissue acquisition.

    Science.gov (United States)

    Schässburger, Kai-Uwe; Paepke, Stefan; Saracco, Ariel; Azavedo, Edward; Ekström, Christina; Wiksell, Hans

    2018-02-01

    Minimally invasive biopsies are a cornerstone of breast cancer management with ultrasound being the preferred guidance modality. New developments in breast cancer management and advances in imaging technologies bring new challenges to current biopsy methodologies. A new biopsy device (NeoNavia® biopsy system, 14 G) was developed. It incorporates a pneumatic needle insertion mechanism that is intended to provide better control of needle progression and enable stepwise insertion without noticeable deformation or displacement of surrounding tissue as visualized under ultrasound. A new method of tissue acquisition was designed to achieve a sampling yield higher than standard methodologies. Needle dynamics was assessed on a specifically designed test bed and sampling performance was compared to a Magnum® biopsy instrument (Bard, Covington, GA, USA) in representative tissue models. The histological quality of samples obtained ex-vivo was evaluated. A pneumatic pulse was measured to accelerate the needle to a maximum velocity of 21.2 ± 2.5 m/s on a stroke length of 2.5 mm, achieving significantly higher acceleration, maximum velocity and power than current biopsy devices. Mean weight of samples obtained by the NeoNavia device were 3.5, 4.6, and 4.3 times higher when sampling was performed in turkey breast, calf thymus and swine pancreas, respectively, as compared to samples obtained with the Magnum instrument. Ex-vivo analysis indicates that the method of tissue acquisition has no apparent negative impact on the histopathologic quality of obtained samples. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  17. Broadband Wireless Data Acquisition and Control Device, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Mobitrum is proposing to develop a broadband wireless device for real-time data acquisition and monitoring applicable to the field instrumentation and control...

  18. MODEL NATIVIS LANGUAGE ACQUISITION DEVICE (SEBUAH TEORI PEMEROLEHAN BAHASA

    Directory of Open Access Journals (Sweden)

    Mamluatul Hasanah

    2011-10-01

    Full Text Available The ability of using mother tongue has been possessed by every child. They can master the language without getting specific education. In a short time a child has mastered the language to communicate with others. There are many theories of language acquisition. One of them that still exists is The Native Model of Language Acquisition (LAD. This theory was pioneered by Noam Chomsky. In this language naturally. This ability develops automatically when the language is used is Language Acquisition Device (LAD. LAD constitutes a hypothesis of feature of grammatical rules used progressively by a child in accordance with his psychological development.

  19. Reactor water sampling device

    International Nuclear Information System (INIS)

    Sakamaki, Kazuo.

    1992-01-01

    The present invention concerns a reactor water sampling device for sampling reactor water in an in-core monitor (neutron measuring tube) housing in a BWR type reactor. The upper end portion of a drain pipe of the reactor water sampling device is attached detachably to an in-core monitor flange. A push-up rod is inserted in the drain pipe vertically movably. A sampling vessel and a vacuum pump are connected to the lower end of the drain pipe. A vacuum pump is operated to depressurize the inside of the device and move the push-up rod upwardly. Reactor water in the in-core monitor housing flows between the drain pipe and the push-up rod and flows into the sampling vessel. With such a constitution, reactor water in the in-core monitor housing can be sampled rapidly with neither opening the lid of the reactor pressure vessel nor being in contact with air. Accordingly, operator's exposure dose can be reduced. (I.N.)

  20. 77 FR 30368 - Defense Federal Acquisition Regulation Supplement; Utilization of Domestic Photovoltaic Devices...

    Science.gov (United States)

    2012-05-22

    ... arrangement, the Government would take title to the devices during contract performance or at the conclusion... rule will promote utilization of domestic photovoltaic devices, even when the Government does not take... Devices (DFARS Case 2011-D046) AGENCY: Defense Acquisition Regulations System, Department of Defense (DoD...

  1. PCI-VME bridge device driver design of a high-performance data acquisition and control system on LINUX

    International Nuclear Information System (INIS)

    Sun Yan; Ye Mei; Zhang Nan; Zhao Jingwei

    2000-01-01

    Data Acquisition and Control is an important part of Nuclear Electronic and Nuclear Detection application in HEP. The key methods are introduced for designing LINUX Device Driver of PCI-VME Bridge Device based on the realized Data Acquisition and Control System

  2. Candidate sample acquisition systems for the Rosetta

    International Nuclear Information System (INIS)

    Magnani, P.G.; Gerli, C.; Colombina, G.; Vielmo, P.

    1989-01-01

    The Comet Nucleus Sample Return (CNSR) mission, one of the four cornerstones of the ESA scientific program, is one of the most complex space ventures within the next century, both from technological and deep space exploration point of view. In the Rosetta scenario the sample acquisition phase represents the most critical point for the global mission's success. The proposed paper illustrates the main results obtained in the context of the CNSR-SAS ongoing activity. The main areas covered are related to: (1) sample properties characterization (comet soil model, physical/chemical properties, reference material for testing); (2) concepts identification for coring, shovelling, harpooning and anchoring; (3) preferred concept (trade off among concepts, identification of the preferred configuration); and (4) proposed development activity for gaining the necessary confidence before finalizing the CNSR mission. Particular emphasis will be given to the robotic and flexibility aspects of the identified sample acquisition systems (SAS) configuration, intended as a means for the overall system performance enhancement

  3. PCI-VME bridge device driver design of a high-performance data acquisition and control system on LINUX

    International Nuclear Information System (INIS)

    Sun Yan; Ye Mei; Zhang Nan; Zhao Jingwei

    2001-01-01

    Data acquisition and control is an important part of nuclear electronic and nuclear detection application in HEP. The key method has been introduced for designing LINUX device driver of PCI-VME bridge device based on realized by authors' data acquisition and control system

  4. Acquisition and Retaining Granular Samples via a Rotating Coring Bit

    Science.gov (United States)

    Bar-Cohen, Yoseph; Badescu, Mircea; Sherrit, Stewart

    2013-01-01

    This device takes advantage of the centrifugal forces that are generated when a coring bit is rotated, and a granular sample is entered into the bit while it is spinning, making it adhere to the internal wall of the bit, where it compacts itself into the wall of the bit. The bit can be specially designed to increase the effectiveness of regolith capturing while turning and penetrating the subsurface. The bit teeth can be oriented such that they direct the regolith toward the bit axis during the rotation of the bit. The bit can be designed with an internal flute that directs the regolith upward inside the bit. The use of both the teeth and flute can be implemented in the same bit. The bit can also be designed with an internal spiral into which the various particles wedge. In another implementation, the bit can be designed to collect regolith primarily from a specific depth. For that implementation, the bit can be designed such that when turning one way, the teeth guide the regolith outward of the bit and when turning in the opposite direction, the teeth will guide the regolith inward into the bit internal section. This mechanism can be implemented with or without an internal flute. The device is based on the use of a spinning coring bit (hollow interior) as a means of retaining granular sample, and the acquisition is done by inserting the bit into the subsurface of a regolith, soil, or powder. To demonstrate the concept, a commercial drill and a coring bit were used. The bit was turned and inserted into the soil that was contained in a bucket. While spinning the bit (at speeds of 600 to 700 RPM), the drill was lifted and the soil was retained inside the bit. To prove this point, the drill was turned horizontally, and the acquired soil was still inside the bit. The basic theory behind the process of retaining unconsolidated mass that can be acquired by the centrifugal forces of the bit is determined by noting that in order to stay inside the interior of the bit, the

  5. A Improved Seabed Surface Sand Sampling Device

    Science.gov (United States)

    Luo, X.

    2017-12-01

    In marine geology research it is necessary to obtain a suf fcient quantity of seabed surface samples, while also en- suring that the samples are in their original state. Currently,there are a number of seabed surface sampling devices available, but we fnd it is very diffcult to obtain sand samples using these devices, particularly when dealing with fne sand. Machine-controlled seabed surface sampling devices are also available, but generally unable to dive into deeper regions of water. To obtain larger quantities of seabed surface sand samples in their original states, many researchers have tried to improve upon sampling devices,but these efforts have generally produced ambiguous results, in our opinion.To resolve this issue, we have designed an improved andhighly effective seabed surface sand sampling device that incorporates the strengths of a variety of sampling devices. It is capable of diving into deepwater to obtain fne sand samples and is also suited for use in streams, rivers, lakes and seas with varying levels of depth (up to 100 m). This device can be used for geological mapping, underwater prospecting, geological engineering and ecological, environmental studies in both marine and terrestrial waters.

  6. Materials and Life Science Experimental Facility at the Japan Proton Accelerator Research Complex III: Neutron Devices and Computational and Sample Environments

    Directory of Open Access Journals (Sweden)

    Kaoru Sakasai

    2017-08-01

    Full Text Available Neutron devices such as neutron detectors, optical devices including supermirror devices and 3He neutron spin filters, and choppers are successfully developed and installed at the Materials Life Science Facility (MLF of the Japan Proton Accelerator Research Complex (J-PARC, Tokai, Japan. Four software components of MLF computational environment, instrument control, data acquisition, data analysis, and a database, have been developed and equipped at MLF. MLF also provides a wide variety of sample environment options including high and low temperatures, high magnetic fields, and high pressures. This paper describes the current status of neutron devices, computational and sample environments at MLF.

  7. Design of Tokamak synchronous data acquisition system based on PXI express

    International Nuclear Information System (INIS)

    Liu Rui; Zheng Wei; Zhang Ming; Weng Chuqiao; Zhuang Ge; Ding Tonghai; Yu Kexun

    2014-01-01

    With the development of J-TEXT device, the original data acquisition system can't meet the experiment's requirement on stability, modularity and sampling rate, so a new data acquisition system needs to be built. This paper introduces the design and implementation of the distributed Tokamak synchronous high-speed data acquisition system based on PXI Express. The acquisition unit consists of PXIe case Nl PXIe 1062Q, PXIe controller NI PXIe-8133 and high-speed synchronous data acquisition card Nl PXIe-6368, compatible with the latest standard of ITER CODAC, so it has good mechanical sealing, strong modularity and high sampling rate etc. The system takes a synchronous difference acquisition for diagnosis signal. The data storage adopts MDSplus which is the general database in the nuclear fusion field. The test and experimental results show that the system can work continuously and stably at 2 MSps sampling rate, and meet the requirement of experiment device's operation well. (authors)

  8. Sampling device for radioactive molten salt

    International Nuclear Information System (INIS)

    Shindo, Masato

    1998-01-01

    The present invention provides a device for accurately sampling molten salts to which various kinds of metals in a molten salt storage tank are mixed for analyzing them during a spent fuel dry type reprocessing. Namely, the device comprises a sampling tube having an opened lower end to be inserted into the radioactive molten salts stored in a tank and keeps reduced pressure from the upper end, and a pressure reducing pipeline having one end connected to the sampling tube and other end connected to an evacuating pump. In this device, the top end of the sampling tube is inserted to a position for sampling the radioactive molten salts (molten salts). The pressure inside the evacuating pipeline connected to the upper portion of the sampling tube is reduced for a while. In this case, the inside of the pressure reducing pipeline is previously evacuated by the evacuating pump so as to keep a predetermined pressure. Since the pressure in the sampling tube is lowered, molten salts are inserted into the sampling tube, the sampling tube is withdrawn, and the molten salts flown in the sampling tube are analyzed. (I.S.)

  9. Design of device driver program for PCI data acquisition adapters based on WDM of windows 2000

    International Nuclear Information System (INIS)

    Yuan Weihua; Qiao Weimin; Jing Lan; Zhu Haijun

    2003-01-01

    The paper describes the design of device driver program for PCI data acquisition adapters based on WDM of Windows 2000. Give an actual example of PCI6208. Now, several data acquisition adapters based in this method are using in national big science engineer HIRFL-CSR. (authors)

  10. Experimental study of glass sampling devices

    International Nuclear Information System (INIS)

    Jouan, A.; Moncouyoux, J.P.; Meyere, A.

    1992-01-01

    Two high-level liquid waste containment glass sampling systems have been designed and built. The first device fits entirely inside a standard glass storage canister, and may thus be used in facilities not initially designed for this function. It has been tested successfully in the nonradioactive prototype unit at Marcoule. The work primarily covered the design and construction of an articulated arm supporting the sampling vessel, and the mechanisms necessary for filling the vessel and recovering the sample. System actuation and operation are fully automatic, and the resulting sample is representative of the glass melt. Implementation of the device is delicate however, and its reliability is estimated at about 75%. A second device was designed specifically for new vitrification facilities. It is installed directly on the glass melting furnace, and meets process operating and quality control requirements. Tests conducted at the Marcoule prototype vitrification facility demonstrated the feasibility of the system. Special attention was given to the sampling vessel transfer mechanisms, with two filling and controlled sample cooling options

  11. Device for sampling liquid radioactive materials

    International Nuclear Information System (INIS)

    Vlasak, L.

    1987-01-01

    Remote sampling of radioactive materials in the process of radioactive waste treatment is claimed by the Czechoslovak Patent Document 238599. The existing difficulties are eliminated consisting in a complex remote control of sampling featuring the control of sliding and rotary movements of the sampling device. The new device consists of a vertical pipe with an opening provided with a cover. A bend is provided above the opening level housing flow distributors. A sampling tray is pivoted in the cover. In sampling, the tray is tilted in the vertical pipe space while it tilts back when filled. The sample flows into a vessel below the tray. Only rotary movement is thus sufficient for controlling the tray. (Z.M.)

  12. Remote control of data acquisition devices by means of message oriented middleware

    International Nuclear Information System (INIS)

    Sanchez, E.; Portas, A.; Pereira, A.; Vega, J.; Kirpitchev, I.

    2007-01-01

    The TJ-II autonomous acquisition systems are computers running dedicated applications for programming and controlling data acquisition channels and also integrating acquired data into the central database. These computers are located in the experimental hall and have to be remotely controlled during plasma discharges. A remote control for these systems has been implemented by taking advantage of the message-oriented middleware recently introduced into the TJ-II data acquisition system. Java Message Service (JMS) is used as the messaging application program interface. All the acquisition actions that are available through the system console of the data acquisition computers (starting or aborting an acquisition, restarting the system or updating the acquisition application) can now be initiated remotely. Command messages are sent to the acquisition systems located in the experimental hall close to the TJ-II device by using the messaging software, without having to use a remote desktop application that produces heavy network traffic and requires manual operation. Action commands can be sent to only one or to several/many acquisition systems at the same time. This software is integrated into the TJ-II remote participation system and the acquisition systems can be commanded from inside or outside the laboratory. All this software is integrated into the security framework provided by PAPI, thus preventing non-authorized users commanding the acquisition computers. In order to dimension and distribute messaging services some performance tests of the message oriented middleware software have been carried out. Results of the tests are presented. As suggested by the tests results different transport connectors are used: TCP transport protocol is used for the local environment, while HTTP protocol is used for remote accesses, thereby allowing the system performance to be optimized

  13. Remote control of data acquisition devices by means of message oriented middleware

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, E. [Asociacion EURATOM/CIEMAT para Fusion, Madrid (Spain)], E-mail: edi.sanchez@ciemat.es; Portas, A.; Pereira, A.; Vega, J.; Kirpitchev, I. [Asociacion EURATOM/CIEMAT para Fusion, Madrid (Spain)

    2007-10-15

    The TJ-II autonomous acquisition systems are computers running dedicated applications for programming and controlling data acquisition channels and also integrating acquired data into the central database. These computers are located in the experimental hall and have to be remotely controlled during plasma discharges. A remote control for these systems has been implemented by taking advantage of the message-oriented middleware recently introduced into the TJ-II data acquisition system. Java Message Service (JMS) is used as the messaging application program interface. All the acquisition actions that are available through the system console of the data acquisition computers (starting or aborting an acquisition, restarting the system or updating the acquisition application) can now be initiated remotely. Command messages are sent to the acquisition systems located in the experimental hall close to the TJ-II device by using the messaging software, without having to use a remote desktop application that produces heavy network traffic and requires manual operation. Action commands can be sent to only one or to several/many acquisition systems at the same time. This software is integrated into the TJ-II remote participation system and the acquisition systems can be commanded from inside or outside the laboratory. All this software is integrated into the security framework provided by PAPI, thus preventing non-authorized users commanding the acquisition computers. In order to dimension and distribute messaging services some performance tests of the message oriented middleware software have been carried out. Results of the tests are presented. As suggested by the tests results different transport connectors are used: TCP transport protocol is used for the local environment, while HTTP protocol is used for remote accesses, thereby allowing the system performance to be optimized.

  14. Microfabricated Devices for Sample Extraction, Concentrations, and Related Sample Processing Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Gang; Lin, Yuehe

    2006-12-01

    This is an invited book chapter. As with other analytical techniques, sample pretreatments, sample extraction, sample introduction, and related techniques are of extreme importance for micro-electro-mechanical systems (MEMS). Bio-MEMS devices and systems start with a sampling step. The biological sample then usually undergoes some kinds of sample preparation steps before the actual analysis. These steps may involve extracting the target sample from its matrix, removing interferences from the sample, derivatizing the sample to detectable species, or performing a sample preconcentration step. The integration of the components for sample pretreatment into microfluidic devices represents one of the remaining the bottle-neck towards achieving true miniaturized total analysis systems (?TAS). This chapter provides a thorough state-of-art of the developments in this field to date.

  15. Sample processing device and method

    DEFF Research Database (Denmark)

    2011-01-01

    A sample processing device is disclosed, which sample processing device comprises a first substrate and a second substrate, where the first substrate has a first surface comprising two area types, a first area type with a first contact angle with water and a second area type with a second contact...... angle with water, the first contact angle being smaller than the second contact angle. The first substrate defines an inlet system and a preparation system in areas of the first type which two areas are separated by a barrier system in an area of the second type. The inlet system is adapted to receive...

  16. Mobile Device Management in the DOD Enterprise Network: Factors for Risk Management, Integration, and It Acquisition

    Science.gov (United States)

    2013-03-01

    Administration NFC Near Field Communications NIST National Institute of Standards and Technology NPRST Navy Personnel Research, Studies, and Technology ...information technology (IT) system acquisition process to acquire a mobile device management (MDM) toolset to mitigate information assurance (IA) risks...method study to understand the concerns of federal information technology professionals who are knowledgeable on MDM and the acquisition

  17. Improving the Acquisition and Management of Sample Curation Data

    Science.gov (United States)

    Todd, Nancy S.; Evans, Cindy A.; Labasse, Dan

    2011-01-01

    This paper discusses the current sample documentation processes used during and after a mission, examines the challenges and special considerations needed for designing effective sample curation data systems, and looks at the results of a simulated sample result mission and the lessons learned from this simulation. In addition, it introduces a new data architecture for an integrated sample Curation data system being implemented at the NASA Astromaterials Acquisition and Curation department and discusses how it improves on existing data management systems.

  18. Sample preparation and detection device for infectious agents

    Science.gov (United States)

    Miles, Robin R.; Wang, Amy W.; Fuller, Christopher K.; Lemoff, Asuncion V.; Bettencourt, Kerry A.; Yu, June

    2003-06-10

    A sample preparation and analysis device which incorporates both immunoassays and PCR assays in one compact, field-portable microchip. The device provides new capabilities in fluid and particle control which allows the building of a fluidic chip with no moving parts, thus decreasing fabrication cost and increasing the robustness of the device. The device can operate in a true continuous (not batch) mode. The device incorporates magnetohydrodynamic (MHD) pumps to move the fluid through the system, acoustic mixing and fractionation, dielectropheretic (DEP) sample concentration and purification, and on-chip optical detection capabilities.

  19. NOTE: A method for controlling image acquisition in electronic portal imaging devices

    Science.gov (United States)

    Glendinning, A. G.; Hunt, S. G.; Bonnett, D. E.

    2001-02-01

    Certain types of camera-based electronic portal imaging devices (EPIDs) which initiate image acquisition based on sensing a change in video level have been observed to trigger unreliably at the beginning of dynamic multileaf collimation sequences. A simple, novel means of controlling image acquisition with an Elekta linear accelerator (Elekta Oncology Systems, Crawley, UK) is proposed which is based on illumination of a photodetector (ORP-12, Silonex Inc., Plattsburgh, NY, USA) by the electron gun of the accelerator. By incorporating a simple trigger circuit it is possible to derive a beam on/off status signal which changes at least 100 ms before any dose is measured by the accelerator. The status signal does not return to the beam-off state until all dose has been delivered and is suitable for accelerator pulse repetition frequencies of 50-400 Hz. The status signal is thus a reliable means of indicating the initiation and termination of radiation exposure, and thus controlling image acquisition of such EPIDs for this application.

  20. Development of an automatic sample changer and a data acquisition system

    International Nuclear Information System (INIS)

    Bianchini, Ricardo M.; Estevez, Jorge; Vollmer, Alberto E.; Iglicki, Flora A.

    1999-01-01

    An automatic electro-pneumatic sample changer with a rotating sample holder is described. The changer is coupled through an electronic interface with the data acquisition station. The software to automate the system has been designed. (author)

  1. Improvement of fuel sampling device for STACY and TRACY

    International Nuclear Information System (INIS)

    Hirose, Hideyuki; Sakuraba, Koichi; Onodera, Seiji

    1998-05-01

    STACY and TRACY, static and transient experiment facilities in NUCEF, use solution fuel. It is important to analyze accurately fuel composition (uranium enrichment, uranium concentration, nitric acid morality, amount of impurities, radioactivity of FP) for their safety operation and improvement of experimental accuracy. Both STACY and TRACY have the sampling devices to sample fuel solution for that purpose. The previous sampling devices of STACY and TRACY had been designed to dilute fuel sample with nitric acid. Its sampling mechanism could pour fuel sample into sampling vessel by a piston drive of nitric acid in the burette. It was, however, sometimes found that sample fuel solution was diluted by mixing with nitric acid in the burette. Therefore, the sampling mechanism was change into a fixed quantity pump drive which didn't use nitric acid. The authors confirmed that the performance of the new sampling device was improved by changing sampling mechanism. It was confirmed through the function test that the uncertainty in uranium concentration measurement using the improved sampling device was 0.14%, and less than the designed value of 0.2% (coefficient of variation). (author)

  2. Crosscutting Development- EVA Tools and Geology Sample Acquisition

    Science.gov (United States)

    2011-01-01

    Exploration to all destinations has at one time or another involved the acquisition and return of samples and context data. Gathered at the summit of the highest mountain, the floor of the deepest sea, or the ice of a polar surface, samples and their value (both scientific and symbolic) have been a mainstay of Earthly exploration. In manned spaceflight exploration, the gathering of samples and their contextual information has continued. With the extension of collecting activities to spaceflight destinations comes the need for geology tools and equipment uniquely designed for use by suited crew members in radically different environments from conventional field geology. Beginning with the first Apollo Lunar Surface Extravehicular Activity (EVA), EVA Geology Tools were successfully used to enable the exploration and scientific sample gathering objectives of the lunar crew members. These early designs were a step in the evolution of Field Geology equipment, and the evolution continues today. Contemporary efforts seek to build upon and extend the knowledge gained in not only the Apollo program but a wealth of terrestrial field geology methods and hardware that have continued to evolve since the last lunar surface EVA. This paper is presented with intentional focus on documenting the continuing evolution and growing body of knowledge for both engineering and science team members seeking to further the development of EVA Geology. Recent engineering development and field testing efforts of EVA Geology equipment for surface EVA applications are presented, including the 2010 Desert Research and Technology Studies (Desert RATs) field trial. An executive summary of findings will also be presented, detailing efforts recommended for exotic sample acquisition and pre-return curation development regardless of planetary or microgravity destination.

  3. Develop of omni-tritium sample preparation device

    International Nuclear Information System (INIS)

    Tian Junhua; Zheng Min; Zhang Dong

    2008-06-01

    The content of total tritium analysis is required in order to know the tritium contaminated degree of biological samples accurately. But the conversion and collection of organic tritium are difficult. A device to treat total tritium samples was developed. Plant samples were treated by combustion and catalysis. After expelling the free HTO in the samples when heated in abundant oxygen, the samples were ignited. Combustion gas passed the catalysts at 800 degree C and its oxidation was catalyzed, and then the combined tritium in tissues was converted into HTO. HTO was collected by water-cooling tube and condenser. For other samples, HTO was treated and collected by high temperature (The highest temperature is 1000 degree C)-catalysis-double condensation method. This device had solved the problem that organic tritium is difficult to gather. (authors)

  4. Sparse-sampling with time-encoded (TICO) stimulated Raman scattering for fast image acquisition

    Science.gov (United States)

    Hakert, Hubertus; Eibl, Matthias; Karpf, Sebastian; Huber, Robert

    2017-07-01

    Modern biomedical imaging modalities aim to provide researchers a multimodal contrast for a deeper insight into a specimen under investigation. A very promising technique is stimulated Raman scattering (SRS) microscopy, which can unveil the chemical composition of a sample with a very high specificity. Although the signal intensities are enhanced manifold to achieve a faster acquisition of images if compared to standard Raman microscopy, there is a trade-off between specificity and acquisition speed. Commonly used SRS concepts either probe only very few Raman transitions as the tuning of the applied laser sources is complicated or record whole spectra with a spectrometer based setup. While the first approach is fast, it reduces the specificity and the spectrometer approach records whole spectra -with energy differences where no Raman information is present-, which limits the acquisition speed. Therefore, we present a new approach based on the TICO-Raman concept, which we call sparse-sampling. The TICO-sparse-sampling setup is fully electronically controllable and allows probing of only the characteristic peaks of a Raman spectrum instead of always acquiring a whole spectrum. By reducing the spectral points to the relevant peaks, the acquisition time can be greatly reduced compared to a uniformly, equidistantly sampled Raman spectrum while the specificity and the signal to noise ratio (SNR) are maintained. Furthermore, all laser sources are completely fiber based. The synchronized detection enables a full resolution of the Raman signal, whereas the analogue and digital balancing allows shot noise limited detection. First imaging results with polystyrene (PS) and polymethylmethacrylate (PMMA) beads confirm the advantages of TICO sparse-sampling. We achieved a pixel dwell time as low as 35 μs for an image differentiating both species. The mechanical properties of the applied voice coil stage for scanning the sample currently limits even faster acquisition.

  5. 30 CFR 90.206 - Approved sampling devices; equivalent concentrations.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; equivalent... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.206 Approved sampling devices; equivalent...

  6. Tube closure device, especially for sample irradiation

    International Nuclear Information System (INIS)

    Klahn, F.C.; Nolan, J.H.; Wills, C.

    1979-01-01

    Device for closing the outlet of a bore and temporarily locking components in this bore. Specifically, it concerns a device for closing a tube containing a set of samples for monitoring irradiation in a nuclear reactor [fr

  7. TMI-2 accident evaluation program sample acquisition and examination plan. Executive summary

    International Nuclear Information System (INIS)

    Russell, M.L.; McCardell, R.K.; Broughton, J.M.

    1985-12-01

    The purpose of the TMI-2 Accident Evaluation Program Sample Acquisition and Examination (TMI-2 AEP SA and E) program is to develop and implement a test and inspection plan that completes the current-condition characterization of (a) the TMI-2 equipment that may have been damaged by the core damage events and (b) the TMI-2 core fission product inventory. The characterization program includes both sample acquisitions and examinations and in-situ measurements. Fission product characterization involves locating the fission products as well as determining their chemical form and determining material association

  8. Device for sampling HTGR recycle fuel particles

    International Nuclear Information System (INIS)

    Suchomel, R.R.; Lackey, W.J.

    1977-03-01

    Devices for sampling High-Temperature Gas-Cooled Reactor fuel microspheres were evaluated. Analysis of samples obtained with each of two specially designed passive samplers were compared with data generated by more common techniques. A ten-stage two-way sampler was found to produce a representative sample with a constant batch-to-sample ratio

  9. A harmonic coil measurement system based on a dynamic signal acquisition device

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, J.X., E-mail: zhoujx@ihep.ac.c [Institute of High Energy Physics, P.O. Box 918-9, Beijing 100049 (China); Li, L.; Yin, B.G.; Deng, C.D.; Kang, W.; Chen, Y.; Zhang, Z.; Fu, S.N. [Institute of High Energy Physics, P.O. Box 918-9, Beijing 100049 (China)

    2010-12-21

    A new harmonic coil measurement system based on a dynamic signal acquisition device has been successfully developed to check the field quality of the quadrupole magnet for the CSNS/RCS, which operates at the 25 Hz excitation cycle with a DC bias. It was designed to acquire multiple channels of data with a wide dynamic range of input signals, which are typically generated by a harmonic coil and an encoder. A dedicated algorithm was developed in LabView code to identify over specified intervals, synchronized to the coil's rotation in the magnetic field. Through full integration of hardware and software, the traditional device (PDI 5025) is replaced successfully. This paper summarizes the characteristics of the system and presents the results of DC measurements.

  10. Development of controller of acquisition and sample positioner for activation for use in measurements of short half-life radioisotopes

    International Nuclear Information System (INIS)

    Secco, Marcello

    2016-01-01

    High resolution gamma spectroscopy measurements have several applications. Those involving short half-life radioisotope measurements may present low precision problems when the radioactive source is far from detector end cup and in the very high activity situations also can present accuracy loss due to dead time and pile-up effects. A way to overcome these problems is changing the source detector distance as the activity is decreasing, and thereby maximizing the statistical counting. In the present study, the Controller of Acquisition and Sample Positioner for Activation (CASPA) was developed. It is a low cost and weight device, made with low atomic number materials designed to assist gamma spectroscopy measurements, which is able to control the distance between the source and the detector, even allowing that there is a change of this distance during the measurement process. Because it is automated it optimizes the time of the operator, who has complete freedom to program their routine measurements in the device besides minimizing the radiation dose in the operator. An interface that allow the user control the CASPA system and to program the acquisition system was created. Tests aiming to optimize the operation of CASPA system were carried out and the safety of the CASPA operation was verified, it was not presented any failure during their tests. It was applied the repeatability tests by the acquisition 60 Co standard source and was found that the positioning of automated system has reproduced the results of static system with a 95% of confidence level. (author)

  11. Water sampling device for fuel rod failure monitoring

    International Nuclear Information System (INIS)

    Oogami, Hideaki; Echigoya, Hironori; Matsuoka, Tesshi.

    1991-01-01

    The device of the present invention accurately samples coolants in a channel box as sampling water even if the upper end of the channel box of a fuel assembly is positioned at the same height or lower than the upper end of an upper lattice plate. An existent device comprises an outer cap, an inner cap, an air supply pipe and a water sampling tube. In addition, the device of the present invention comprises a sealing material disposed at the end of the outer cap for keeping liquid sealing with the upper lattice plate and a water level monitoring pipe extended to lower than the inner cap passing through the liquid sealing of the outer cap for sucking the atmosphere in the outer cap. Pressurized air is sent through the air supply pipe, to lower the water level of the coolants in the outer cap and the water level monitoring pipe sucks the pressurized air, by which the inside and the outside of the channel box are partitioned. Subsequently, if the sample water is sampled by a sampling tube, sampling water which enables accurate evaluation for radioactivity concentration in the fuel assembly can be obtained. (I.S.)

  12. Use of Low-Cost Acquisition Systems with an Embedded Linux Device for Volcanic Monitoring.

    Science.gov (United States)

    Moure, David; Torres, Pedro; Casas, Benito; Toma, Daniel; Blanco, María José; Del Río, Joaquín; Manuel, Antoni

    2015-08-19

    This paper describes the development of a low-cost multiparameter acquisition system for volcanic monitoring that is applicable to gravimetry and geodesy, as well as to the visual monitoring of volcanic activity. The acquisition system was developed using a System on a Chip (SoC) Broadcom BCM2835 Linux operating system (based on DebianTM) that allows for the construction of a complete monitoring system offering multiple possibilities for storage, data-processing, configuration, and the real-time monitoring of volcanic activity. This multiparametric acquisition system was developed with a software environment, as well as with different hardware modules designed for each parameter to be monitored. The device presented here has been used and validated under different scenarios for monitoring ocean tides, ground deformation, and gravity, as well as for monitoring with images the island of Tenerife and ground deformation on the island of El Hierro.

  13. Effects of Video Caption Modes on English Listening Comprehension and Vocabulary Acquisition Using Handheld Devices

    Science.gov (United States)

    Hsu, Ching-Kun; Hwang, Gwo-Jen; Chang, Yu-Tzu; Chang, Chih-Kai

    2013-01-01

    This study investigates the effects of different display modes of video captions on mobile devices, including non-caption, full-caption, and target-word modes, on the English comprehension and vocabulary acquisition of fifth graders. During the one-month experiment, the status of the students' English listening comprehension and vocabulary…

  14. 30 CFR 90.204 - Approved sampling devices; maintenance and calibration.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; maintenance and... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.204 Approved sampling devices; maintenance and...

  15. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; operation; air... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate...

  16. A device for fresh water sampling before radioactive measurements

    International Nuclear Information System (INIS)

    Maubert, Henri; Picat, Philippe.

    1982-06-01

    On account of the many field operations carried out by the laboratory, a water sampling device has been developed. This portable autonomous device performs in situ water filtration and concentration on ion exchange resins and activated carbon columns. The device is described and the trapping performance for 8 radionuclides is given. A comparison is made with the so-called evaporation method. The effects of the treatment of the filtrating elements on the radioactive results are studied. This sampling method is very sensitive [fr

  17. Minimal BRDF Sampling for Two-Shot Near-Field Reflectance Acquisition

    DEFF Research Database (Denmark)

    Xu, Zexiang; Nielsen, Jannik Boll; Yu, Jiyang

    2016-01-01

    We develop a method to acquire the BRDF of a homogeneous flat sample from only two images, taken by a near-field perspective camera, and lit by a directional light source. Our method uses the MERL BRDF database to determine the optimal set of lightview pairs for data-driven reflectance acquisition...

  18. Optimizing the data acquisition rate for a remotely controllable structural monitoring system with parallel operation and self-adaptive sampling

    International Nuclear Information System (INIS)

    Sheng, Wenjuan; Guo, Aihuang; Liu, Yang; Azmi, Asrul Izam; Peng, Gang-Ding

    2011-01-01

    We present a novel technique that optimizes the real-time remote monitoring and control of dispersed civil infrastructures. The monitoring system is based on fiber Bragg gating (FBG) sensors, and transfers data via Ethernet. This technique combines parallel operation and self-adaptive sampling to increase the data acquisition rate in remote controllable structural monitoring systems. The compact parallel operation mode is highly efficient at achieving the highest possible data acquisition rate for the FBG sensor based local data acquisition system. Self-adaptive sampling is introduced to continuously coordinate local acquisition and remote control for data acquisition rate optimization. Key issues which impact the operation of the whole system, such as the real-time data acquisition rate, data processing capability, and buffer usage, are investigated. The results show that, by introducing parallel operation and self-adaptive sampling, the data acquisition rate can be increased by several times without affecting the system operating performance on both local data acquisition and remote process control

  19. Design of General-purpose Industrial signal acquisition system in a large scientific device

    Science.gov (United States)

    Ren, Bin; Yang, Lei

    2018-02-01

    In order to measure the industrial signal of a large scientific device experiment, a set of industrial data general-purpose acquisition system has been designed. It can collect 4~20mA current signal and 0~10V voltage signal. Through the practical experiments, it shows that the system is flexible, reliable, convenient and economical, and the system has characters of high definition and strong anti-interference ability. Thus, the system fully meets the design requirements..

  20. Device for radioactivity measurement of liquid samples

    International Nuclear Information System (INIS)

    Lamaziere, J.

    1983-01-01

    The device for low activity gamma measurements comprises an automatic changer for sample transfer from a conveyor to a measuring chamber. The conveyor includes a horizontal table were are regularly distributed sample holders. A lift allows a vertical motion of a plate for the exposition in front of a detector [fr

  1. BioDAQ--a simple biosignal acquisition system for didactic use.

    Science.gov (United States)

    Csaky, Z; Mihalas, G I; Focsa, M

    2002-01-01

    A simple non expensive device for biosignal acquisition is presented. It mainly meets the requirements for didactic purposes specific in medical informatics laboratory classes. The system has two main types of devices: 'student unit'--the simplest one, used during lessons on real signals and 'demo unit', which can be also used in medical practice or for collecting biological signals. It is able to record: optical pulse, sphygmogram, ECG (1-4 leads) EEG or EMG (1-4 channels). For didactical purposes it has a large scale of recording options: variable sampling rate, gain and filtering. It can also be used in tele-acquisition via Internet.

  2. The implementation of a data acquisition and service system based on HDF5

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y., E-mail: cheny@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Wang, F.; Li, S. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Xiao, B.J. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); School of nuclear science and technology, University of Science and Technology of China, Hefei, Anhui (China); Yang, F. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Department of Computer Science, Anhui Medical University, Hefei, Anhui (China)

    2016-11-15

    Highlights: • A new data acquisition and service system has been designed and implemented for a new reversed field pinch (RFP) magnetic confinement device. • The new data acquisition and service system is based on HDF5. • It is an entire system including acquisition, storage and data retrieval. • The system is easy to extend and maintain for its modularization design. - Abstract: A data acquisition and service system based on HDF5 has been designed. It includes four components: data acquisition console, data acquisition subsystem, data archive system and data service. The data acquisition console manages all DAQ information and controls the acquisition process. The data acquisition subsystem supports continuous data acquisition with different sampling rates which can be divided into low, medium and high level. All experimental data will be remotely transferred to the data archive system. It adopts HDF5 as its low-level data storage format. The hierarchical data structure of HDF5 is useful for efficiently managing the experimental data and allows users to define special data types and compression filter which can be useful to deal with special signals. Several data service tools have also been developed so that users can get data service via Client/Server or Brower/Server. The system will be demonstrated on Keda Torus eXperiment (KTX) device, which is a new Reversed Field Pinch (RFP) magnetic confinement device. The details are presented in the paper.

  3. The implementation of a data acquisition and service system based on HDF5

    International Nuclear Information System (INIS)

    Chen, Y.; Wang, F.; Li, S.; Xiao, B.J.; Yang, F.

    2016-01-01

    Highlights: • A new data acquisition and service system has been designed and implemented for a new reversed field pinch (RFP) magnetic confinement device. • The new data acquisition and service system is based on HDF5. • It is an entire system including acquisition, storage and data retrieval. • The system is easy to extend and maintain for its modularization design. - Abstract: A data acquisition and service system based on HDF5 has been designed. It includes four components: data acquisition console, data acquisition subsystem, data archive system and data service. The data acquisition console manages all DAQ information and controls the acquisition process. The data acquisition subsystem supports continuous data acquisition with different sampling rates which can be divided into low, medium and high level. All experimental data will be remotely transferred to the data archive system. It adopts HDF5 as its low-level data storage format. The hierarchical data structure of HDF5 is useful for efficiently managing the experimental data and allows users to define special data types and compression filter which can be useful to deal with special signals. Several data service tools have also been developed so that users can get data service via Client/Server or Brower/Server. The system will be demonstrated on Keda Torus eXperiment (KTX) device, which is a new Reversed Field Pinch (RFP) magnetic confinement device. The details are presented in the paper.

  4. Nano-Scale Sample Acquisition Systems for Small Class Exploration Spacecraft

    Science.gov (United States)

    Paulsen, G.

    2015-12-01

    The paradigm for space exploration is changing. Large and expensive missions are very rare and the space community is turning to smaller, lighter, and less expensive missions that could still perform great exploration. These missions are also within reach of commercial companies such as the Google Lunar X Prize teams that develop small scale lunar missions. Recent commercial endeavors such as "Planet Labs inc." and Sky Box Imaging, inc. show that there are new benefits and business models associated with miniaturization of space hardware. The Nano-Scale Sample Acquisition System includes NanoDrill for capture of small rock cores and PlanetVac for capture of surface regolith. These two systems are part of the ongoing effort to develop "Micro Sampling" systems for deployment by the small spacecraft with limited payload capacities. The ideal applications include prospecting missions to the Moon and Asteroids. The MicroDrill is a rotary-percussive coring drill that captures cores 7 mm in diameter and up to 2 cm long. The drill weighs less than 1 kg and can capture a core from a 40 MPa strength rock within a few minutes, with less than 10 Watt power and less than 10 Newton of preload. The PlanetVac is a pneumatic based regolith acquisition system that can capture surface sample in touch-and-go maneuver. These sampling systems were integrated within the footpads of commercial quadcopter for testing. As such, they could also be used by geologists on Earth to explore difficult to get to locations.

  5. Development of a custom monolithic device for data acquisition from a scintillating calorimeter at the superconducting super collider

    International Nuclear Information System (INIS)

    Ekenberg, T.; Dawson, J.W.; Talaga, R.L.; Stevens, A.E.; Haberichter, W.N.

    1991-01-01

    A clock-driven continuous sequential write/random read data acquisition architecture for a scintillating calorimeter at the SSC is presented. Simplicity of design and operation as well as potentially dead time-less operation are the motivations of this effort. The architecture minimizes the number of fast control signals, thereby reducing pickup from digital control lines by sensitive analog circuits in the front-end device. This architecture also reduces the logic necessary on the front-end device improving reliability and easing design and operation. Operation and design of the front-end device are discussed. 3 refs., 7 figs

  6. CAMAC interface for TPC data-acquisition electronics

    International Nuclear Information System (INIS)

    Sidman, S.; Olson, S.; Jared, R.

    1983-06-01

    The Time Projection Chamber (TPC) is a detector used for high-energy physics research at the Stanford PEP Accelerator. TPC requires about 17,000 channels of data acquisition, which samples on command the input to each channel at a 10 MHz rate. This high data rate is made possible by means of Charge Coupled Devices (CCDs), intelligent digitizers, and a sophisticated trigger system. The TPC-CAMAC interface described here was developed to allow experiments of smaller scale than the complete TPC to use the standard data acquisition portion of the TPC electronics, namely the amplifier, CCD and digitizer bins. These three bins, when properly interconnected and controlled by the interface control bin, form a transient digitizer with a depth of 455 samples and a maximum width of 256 channels per bin set

  7. Three-dimensional image acquisition and reconstruction system on a mobile device based on computer-generated integral imaging.

    Science.gov (United States)

    Erdenebat, Munkh-Uchral; Kim, Byeong-Jun; Piao, Yan-Ling; Park, Seo-Yeon; Kwon, Ki-Chul; Piao, Mei-Lan; Yoo, Kwan-Hee; Kim, Nam

    2017-10-01

    A mobile three-dimensional image acquisition and reconstruction system using a computer-generated integral imaging technique is proposed. A depth camera connected to the mobile device acquires the color and depth data of a real object simultaneously, and an elemental image array is generated based on the original three-dimensional information for the object, with lens array specifications input into the mobile device. The three-dimensional visualization of the real object is reconstructed on the mobile display through optical or digital reconstruction methods. The proposed system is implemented successfully and the experimental results certify that the system is an effective and interesting method of displaying real three-dimensional content on a mobile device.

  8. Fast acquisition of multidimensional NMR spectra of solids and mesophases using alternative sampling methods.

    Science.gov (United States)

    Lesot, Philippe; Kazimierczuk, Krzysztof; Trébosc, Julien; Amoureux, Jean-Paul; Lafon, Olivier

    2015-11-01

    Unique information about the atom-level structure and dynamics of solids and mesophases can be obtained by the use of multidimensional nuclear magnetic resonance (NMR) experiments. Nevertheless, the acquisition of these experiments often requires long acquisition times. We review here alternative sampling methods, which have been proposed to circumvent this issue in the case of solids and mesophases. Compared to the spectra of solutions, those of solids and mesophases present some specificities because they usually display lower signal-to-noise ratios, non-Lorentzian line shapes, lower spectral resolutions and wider spectral widths. We highlight herein the advantages and limitations of these alternative sampling methods. A first route to accelerate the acquisition time of multidimensional NMR spectra consists in the use of sparse sampling schemes, such as truncated, radial or random sampling ones. These sparsely sampled datasets are generally processed by reconstruction methods differing from the Discrete Fourier Transform (DFT). A host of non-DFT methods have been applied for solids and mesophases, including the G-matrix Fourier transform, the linear least-square procedures, the covariance transform, the maximum entropy and the compressed sensing. A second class of alternative sampling consists in departing from the Jeener paradigm for multidimensional NMR experiments. These non-Jeener methods include Hadamard spectroscopy as well as spatial or orientational encoding of the evolution frequencies. The increasing number of high field NMR magnets and the development of techniques to enhance NMR sensitivity will contribute to widen the use of these alternative sampling methods for the study of solids and mesophases in the coming years. Copyright © 2015 John Wiley & Sons, Ltd.

  9. Description of a portable wireless device for high-frequency body temperature acquisition and analysis.

    Science.gov (United States)

    Cuesta-Frau, David; Varela, Manuel; Aboy, Mateo; Miró-Martínez, Pau

    2009-01-01

    We describe a device for dual channel body temperature monitoring. The device can operate as a real time monitor or as a data logger, and has Bluetooth capabilities to enable for wireless data download to the computer used for data analysis. The proposed device is capable of sampling temperature at a rate of 1 sample per minute with a resolution of 0.01 °C . The internal memory allows for stand-alone data logging of up to 10 days. The device has a battery life of 50 hours in continuous real-time mode. In addition to describing the proposed device in detail, we report the results of a statistical analysis conducted to assess its accuracy and reproducibility.

  10. Sampling device for withdrawing a representative sample from single and multi-phase flows

    Science.gov (United States)

    Apley, Walter J.; Cliff, William C.; Creer, James M.

    1984-01-01

    A fluid stream sampling device has been developed for the purpose of obtaining a representative sample from a single or multi-phase fluid flow. This objective is carried out by means of a probe which may be inserted into the fluid stream. Individual samples are withdrawn from the fluid flow by sampling ports with particular spacings, and the sampling parts are coupled to various analytical systems for characterization of the physical, thermal, and chemical properties of the fluid flow as a whole and also individually.

  11. Test plan for K Basin Sludge Canister and Floor Sampling Device

    International Nuclear Information System (INIS)

    Meling, T.A.

    1995-01-01

    This document provides the test plan and procedure forms for conducting the functional and operational acceptance testing of the K Basin Sludge Canister and Floor Sampling Device(s). These samplers samples sludge off the floor of the 100K Basins and out of 100K fuel storage canisters

  12. Dynamic Acquisition and Retrieval Tool (DART) for Comet Sample Return : Session: 2.06.Robotic Mobility and Sample Acquisition Systems

    Science.gov (United States)

    Badescu, Mircea; Bonitz, Robert; Kulczycki, Erick; Aisen, Norman; Dandino, Charles M.; Cantrell, Brett S.; Gallagher, William; Shevin, Jesse; Ganino, Anthony; Haddad, Nicolas; hide

    2013-01-01

    The 2011 Decadal Survey for planetary science released by the National Research Council of the National Academies identified Comet Surface Sample Return (CSSR) as one of five high priority potential New Frontiers-class missions in the next decade. The main objectives of the research described in this publication are: develop a concept for an end-to-end system for collecting and storing a comet sample to be returned to Earth; design, fabricate and test a prototype Dynamic Acquisition and Retrieval Tool (DART) capable of collecting 500 cc sample in a canister and eject the canister with a predetermined speed; identify a set of simulants with physical properties at room temperature that suitably match the physical properties of the comet surface as it would be sampled. We propose the use of a dart that would be launched from the spacecraft to impact and penetrate the comet surface. After collecting the sample, the sample canister would be ejected at a speed greater than the comet's escape velocity and captured by the spacecraft, packaged into a return capsule and returned to Earth. The dart would be composed of an inner tube or sample canister, an outer tube, a decelerator, a means of capturing and retaining the sample, and a mechanism to eject the canister with the sample for later rendezvous with the spacecraft. One of the significant unknowns is the physical properties of the comet surface. Based on new findings from the recent Deep Impact comet encounter mission, we have limited our search of solutions for sampling materials to materials with 10 to 100 kPa shear strength in loose or consolidated form. As the possible range of values for the comet surface temperature is also significantly different than room temperature and testing at conditions other than the room temperature can become resource intensive, we sought sample simulants with physical properties at room temperature similar to the expected physical properties of the comet surface material. The chosen

  13. Development of a magnetic measurement device for thin ribbon samples

    International Nuclear Information System (INIS)

    Sato, Yuta; Todaka, Takashi; Enokizono, Masato

    2008-01-01

    This paper presents a magnetic measurement device for thin ribbon samples, which are produced by rapid cooling technique. This device enables us to measure magnetic properties easily by only inserting a ribbon sample into a sample holder. The sample holder was made by bakelite to fix any width sample. A long solenoid coil was used to generate a uniform magnetic field and the sample holder was placed at the mid part of the solenoid. The magnetic field strength was measured using a shunt resistor and the magnetic flux density and magnetization in sample ribbons were evaluated by using search coils. The accuracy of measurement was verified with an amorphous metal ribbon sample. Next, we have measured magnetic properties of some magnetic shape memory alloys, which have different compositions. The measured results are compared and we clarified the effect of Sm contents on the magnetic properties

  14. Cryogenic Liquid Sample Acquisition System for Remote Space Applications

    Science.gov (United States)

    Mahaffy, Paul; Trainer, Melissa; Wegel, Don; Hawk, Douglas; Melek, Tony; Johnson, Christopher; Amato, Michael; Galloway, John

    2013-01-01

    There is a need to acquire autonomously cryogenic hydrocarbon liquid sample from remote planetary locations such as the lakes of Titan for instruments such as mass spectrometers. There are several problems that had to be solved relative to collecting the right amount of cryogenic liquid sample into a warmer spacecraft, such as not allowing the sample to boil off or fractionate too early; controlling the intermediate and final pressures within carefully designed volumes; designing for various particulates and viscosities; designing to thermal, mass, and power-limited spacecraft interfaces; and reducing risk. Prior art inlets for similar instruments in spaceflight were designed primarily for atmospheric gas sampling and are not useful for this front-end application. These cryogenic liquid sample acquisition system designs for remote space applications allow for remote, autonomous, controlled sample collections of a range of challenging cryogenic sample types. The design can control the size of the sample, prevent fractionation, control pressures at various stages, and allow for various liquid sample levels. It is capable of collecting repeated samples autonomously in difficult lowtemperature conditions often found in planetary missions. It is capable of collecting samples for use by instruments from difficult sample types such as cryogenic hydrocarbon (methane, ethane, and propane) mixtures with solid particulates such as found on Titan. The design with a warm actuated valve is compatible with various spacecraft thermal and structural interfaces. The design uses controlled volumes, heaters, inlet and vent tubes, a cryogenic valve seat, inlet screens, temperature and cryogenic liquid sensors, seals, and vents to accomplish its task.

  15. Design of FPGA based high-speed data acquisition and real-time data processing system on J-TEXT tokamak

    International Nuclear Information System (INIS)

    Zheng, W.; Liu, R.; Zhang, M.; Zhuang, G.; Yuan, T.

    2014-01-01

    Highlights: • It is a data acquisition system for polarimeter–interferometer diagnostic on J-TEXT tokamak based on FPGA and PXIe devices. • The system provides a powerful data acquisition and real-time data processing performance. • Users can implement different data processing applications on the FPGA in a short time. • This system supports EPICS and has been integrated into the J-TEXT CODAC system. - Abstract: Tokamak experiment requires high-speed data acquisition and processing systems. In traditional data acquisition system, the sampling rate, channel numbers and processing speed are limited by bus throughput and CPU speed. This paper presents a data acquisition and processing system based on FPGA. The data can be processed in real-time before it is passed to the CPU. It provides processing ability for more channels with higher sampling rates than the traditional data acquisition system while ensuring deterministic real-time performance. A working prototype is developed for the newly built polarimeter–interferometer diagnostic system on the Joint Texas Experimental Tokamak (J-TEXT). It provides 16 channels with 120 MHz maximum sampling rate and 16 bit resolution. The onboard FPGA is able to calculate the plasma electron density and Faraday rotation angel. A RAID 5 storage device is adopted providing 700 MB/s read–write speed to buffer the data to the hard disk continuously for better performance

  16. Feasibility study of a XML-based software environment to manage data acquisition hardware devices

    International Nuclear Information System (INIS)

    Arcidiacono, R.; Brigljevic, V.; Bruno, G.; Cano, E.; Cittolin, S.; Erhan, S.; Gigi, D.; Glege, F.; Gomez-Reino, R.; Gulmini, M.; Gutleber, J.; Jacobs, C.; Kreuzer, P.; Lo Presti, G.; Magrans, I.; Marinelli, N.; Maron, G.; Meijers, F.; Meschi, E.; Murray, S.; Nafria, M.; Oh, A.; Orsini, L.; Pieri, M.; Pollet, L.; Racz, A.; Rosinsky, P.; Schwick, C.; Sphicas, P.; Varela, J.

    2005-01-01

    A Software environment to describe configuration, control and test systems for data acquisition hardware devices is presented. The design follows a model that enforces a comprehensive use of an extensible markup language (XML) syntax to describe both the code and associated data. A feasibility study of this software, carried out for the CMS experiment at CERN, is also presented. This is based on a number of standalone applications for different hardware modules, and the design of a hardware management system to remotely access to these heterogeneous subsystems through a uniform web service interface

  17. Feasibility study of a XML-based software environment to manage data acquisition hardware devices

    Energy Technology Data Exchange (ETDEWEB)

    Arcidiacono, R. [Massachusetts Institute of Technology, Cambridge, MA (United States); Brigljevic, V. [CERN, Geneva (Switzerland); Rudjer Boskovic Institute, Zagreb (Croatia); Bruno, G. [CERN, Geneva (Switzerland); Cano, E. [CERN, Geneva (Switzerland); Cittolin, S. [CERN, Geneva (Switzerland); Erhan, S. [University of California, Los Angeles, Los Angeles, CA (United States); Gigi, D. [CERN, Geneva (Switzerland); Glege, F. [CERN, Geneva (Switzerland); Gomez-Reino, R. [CERN, Geneva (Switzerland); Gulmini, M. [INFN-Laboratori Nazionali di Legnaro, Legnaro (Italy); CERN, Geneva (Switzerland); Gutleber, J. [CERN, Geneva (Switzerland); Jacobs, C. [CERN, Geneva (Switzerland); Kreuzer, P. [University of Athens, Athens (Greece); Lo Presti, G. [CERN, Geneva (Switzerland); Magrans, I. [CERN, Geneva (Switzerland) and Electronic Engineering Department, Universidad Autonoma de Barcelona, Barcelona (Spain)]. E-mail: ildefons.magrans@cern.ch; Marinelli, N. [Institute of Accelerating Systems and Applications, Athens (Greece); Maron, G. [INFN-Laboratori Nazionali di Legnaro, Legnaro (Italy); Meijers, F. [CERN, Geneva (Switzerland); Meschi, E. [CERN, Geneva (Switzerland); Murray, S. [CERN, Geneva (Switzerland); Nafria, M. [Electronic Engineering Department, Universidad Autonoma de Barcelona, Barcelona (Spain); Oh, A. [CERN, Geneva (Switzerland); Orsini, L. [CERN, Geneva (Switzerland); Pieri, M. [University of California, San Diago, San Diago, CA (United States); Pollet, L. [CERN, Geneva (Switzerland); Racz, A. [CERN, Geneva (Switzerland); Rosinsky, P. [CERN, Geneva (Switzerland); Schwick, C. [CERN, Geneva (Switzerland); Sphicas, P. [University of Athens, Athens (Greece); CERN, Geneva (Switzerland); Varela, J. [LIP, Lisbon (Portugal); CERN, Geneva (Switzerland)

    2005-07-01

    A Software environment to describe configuration, control and test systems for data acquisition hardware devices is presented. The design follows a model that enforces a comprehensive use of an extensible markup language (XML) syntax to describe both the code and associated data. A feasibility study of this software, carried out for the CMS experiment at CERN, is also presented. This is based on a number of standalone applications for different hardware modules, and the design of a hardware management system to remotely access to these heterogeneous subsystems through a uniform web service interface.

  18. Paper Capillary Enables Effective Sampling for Microfluidic Paper Analytical Devices.

    Science.gov (United States)

    Shangguan, Jin-Wen; Liu, Yu; Wang, Sha; Hou, Yun-Xuan; Xu, Bi-Yi; Xu, Jing-Juan; Chen, Hong-Yuan

    2018-06-06

    Paper capillary is introduced to enable effective sampling on microfluidic paper analytical devices. By coupling mac-roscale capillary force of paper capillary and microscale capillary forces of native paper, fluid transport can be flexibly tailored with proper design. Subsequently, a hybrid-fluid-mode paper capillary device was proposed, which enables fast and reliable sampling in an arrayed form, with less surface adsorption and bias for different components. The resulting device thus well supports high throughput, quantitative, and repeatable assays all by hands operation. With all these merits, multiplex analysis of ions, proteins, and microbe have all been realized on this platform, which has paved the way to level-up analysis on μPADs.

  19. Integration of autonomous systems for remote control of data acquisition and diagnostics in the TJ-II device

    International Nuclear Information System (INIS)

    Vega, J.; Mollinedo, A.; Lopez, A.; Pacios, L.; Dormido, S.

    1997-01-01

    The data acquisition system for TJ-II will consist of a central computer, containing the data base of the device, and a set of independent systems (personal computers, embedded ones, workstations, minicomputers, PLCs, and microprocessor systems among others), controlling data collection, and automated diagnostics. Each autonomous system can be used to isolate and manage specific problems in the most efficient manner. These problems are related to data acquisition, hard (μs endash ms) real time requirements, soft (ms endash s) real time requirements, remote control of diagnostics, etc. In the operation of TJ-II, the programming of systems will be carried out from the central computer. Coordination and synchronization will be performed by linking systems to local area networks. Several Ethernet segments and FDDI rings will be used for these purposes. Programmable logic controller devices (PLCs) used for diagnostic low level control will be linked among them through a fast serial link, the RS485 Profibus standard. One VME crate, running on the OS-9 real time operating system, will be assigned as a gateway, so as to connect the PLCs based systems with an Ethernet segment. copyright 1997 American Institute of Physics

  20. Air-deployable oil spill sampling devices review phase 2 testing. Volume 1

    International Nuclear Information System (INIS)

    Hawke, L.; Dumouchel, A.; Fingas, M.; Brown, C.E.

    2007-01-01

    SAIC Canada tested air deployable oil sampling devices for the Emergencies Science and Technology Division of Environment Canada in order to determine the applicability and status of these devices. The 3 devices tested were: Canada's SABER (sampling autonomous buoy for evidence recovery), the United States' POPEIE (probe for oil pollution evidence in the environment); and, Sweden's SAR Floatation 2000. They were tested for buoyancy properties, drift behaviour and sampler sorbent pickup ratios. The SAR and SABER both had lesser draft and greater freeboard, while the POPEIE had much greater draft than freeboard. All 3 devices could be used for oil sample collection in that their drift characteristics would allow for the SABER and SAR devices to be placed upwind of the slick while the POPEIE device could be placed downwind of an oil spill. The sorbent testing revealed that Sefar sorbent and Spectra sorbent used in the 3 devices had negative pickup ratios for diesel but performance improved as oil viscosity increased. Both sorbents are inert and capable of collecting oil in sufficient volumes for consistent fingerprinting analysis. 10 refs., 8 tabs., 8 figs

  1. Velocity Vector Field Visualization of Flow in Liquid Acquisition Device Channel

    Science.gov (United States)

    McQuillen, John B.; Chao, David F.; Hall, Nancy R.; Zhang, Nengli

    2012-01-01

    A capillary flow liquid acquisition device (LAD) for cryogenic propellants has been developed and tested in NASA Glenn Research Center to meet the requirements of transferring cryogenic liquid propellants from storage tanks to an engine in reduced gravity environments. The prototypical mesh screen channel LAD was fabricated with a mesh screen, covering a rectangular flow channel with a cylindrical outlet tube, and was tested with liquid oxygen (LOX). In order to better understand the performance in various gravity environments and orientations at different liquid submersion depths of the screen channel LAD, a series of computational fluid dynamics (CFD) simulations of LOX flow through the LAD screen channel was undertaken. The resulting velocity vector field visualization for the flow in the channel has been used to reveal the gravity effects on the flow in the screen channel.

  2. 78 FR 25308 - Proposed Collection; Comment Request; Coal Mine Dust Sampling Devices

    Science.gov (United States)

    2013-04-30

    ...; Coal Mine Dust Sampling Devices AGENCY: Mine Safety and Health Administration, Labor. ACTION: 60-Day... mines. CPDMs must be designed and constructed for coal miners to wear and operate without impeding their... related to Coal Mine Dust Sampling Devices. MSHA is particularly interested in comments that: Evaluate...

  3. Integrating a sampling oscilloscope card and spectroscopy ADCs in a data acquisition system

    CERN Document Server

    Maartensson, L

    2001-01-01

    A high-rate sampling oscilloscope card has been integrated into an existing data acquisition system for spectroscopy ADCs. Experiments where pulse-shape analyses are important have then been made possible. Good performance characteristics of the integrated system have been achieved. Spectroscopy ADC data together with pulse-shape data sampled 512 times at 100 MHz are saved to hard disk at event rates up to about 1 kHz with low dead time losses.

  4. Device for sampling radioactive and aggressive liquid and vaporous media

    International Nuclear Information System (INIS)

    Przibram, E.; Halm, G.

    1974-01-01

    The equipment enables the taking of samples even of radioactive media from a main pipeline in the through-flow in a closed system. A tap device is attached to the main pipeline which branches into two parts. The one branch contains the actual tap which is closed to both sides with snap closure coupling. It is only used for taking samples. The other branch bridges the tap position as a bypass so that a representative sample is always available. Both branches join up again and lead back to the main pipeline. The sampling can be used in a nuclear power plant for the determination of O 2 , CI, SiO 2 , and Cu. A millilitre collecting cylinder and a millipore filtration device can be connected to the tap for liquid sampling and solid analysis, respectively. The system can be extended to several tap positions. Permanent measuring equipment is attached to the bypass pipe to control the sample liquid. (DG) [de

  5. Sample taking device for toxic and/or radioactive substances

    International Nuclear Information System (INIS)

    Finsterwalder, L.; Zeh, H.; Schaarschmidt, U.

    1979-01-01

    An apparatus for taking samples of toxic and/or radioactive liquid substances by introducing such substances into sample vessels includes a holder for holding such a vessel, at least one needle head filling system composed of upwardly pointing hollow needles for introducing a sample of one such substance into such a vessel at a filling position, and inlet and outlet conduits for pneumatically conveying vessels to or from the holder at a transfer position. The holder is composed of a turntable having a sleeve for accommodating such vessel and is mounted to undergo rotary movement to convey a sample vessel held in the sleeve between the filling and transfer positions. The apparatus further includes a stand supporting the filling system below the holder and a lifting device connected for imparting a translational movement to the holder to bring a vessel in the holder to operative association with the filling system. The lifting device is arranged so that the translational movement which it produces is independent of the rotary movement of the turntable

  6. Results from evaluation of a long pulse pilot data acquisition system on MAST

    International Nuclear Information System (INIS)

    McArdle, G.J.; Milne, P.G.

    2006-01-01

    The limited memory and data rate of CAMAC data acquisition systems is unable to accommodate proposed increases in the MAST plasma duration of up to an order of magnitude. Therefore, some recent pilot exercises have evaluated new technology to replace CAMAC. One of the pilot systems explored the use of modern CompactPCI 'intelligent' data acquisition devices. These can operate stand-alone, using an onboard Linux operating system and Ethernet connection without the need for a host computer. The approach to data capture and management was simplified to minimise development time. A simple Linux shell script running on each device was found sufficient to automate the whole acquisition cycle, and this was successfully commissioned in one day. This approach avoided the need for compiled programs but prevented use of the in-house standard shot file archiving library. Instead, each channel's data was written to a separate file as a simple array of samples. This work around was found to offer advantages in terms of flexibility, simplicity and scalability. The experience of handling much higher volumes of acquired data than was practicable with CAMAC has also raised important issues about the scalability of existing data management and analysis systems when each data item contains many mega-samples. The experience and lessons learned will help guide the future direction of data acquisition strategy on MAST

  7. Screen Channel Liquid Acquisition Device Outflow Tests in Liquid Hydrogen

    Science.gov (United States)

    Hartwig, Jason W.; Chato, David J.; McQuillen, J. B.; Vera, J.; Kudlac, M. T.; Quinn, F. D.

    2013-01-01

    This paper presents experimental design and test results of the recently concluded 1-g inverted vertical outflow testing of two 325x2300 full scale liquid acquisition device (LAD) channels in liquid hydrogen (LH2). One of the channels had a perforated plate and internal cooling from a thermodynamic vent system (TVS) to enhance performance. The LADs were mounted in a tank to simulate 1-g outflow over a wide range of LH2 temperatures (20.3 - 24.2 K), pressures (100 - 350 kPa), and flow rates (0.010 - 0.055 kg/s). Results indicate that the breakdown point is dominated by liquid temperature, with a second order dependence on mass flow rate through the LAD. The best performance is always achieved in the coldest liquid states for both channels, consistent with bubble point theory. Higher flow rates cause the standard channel to break down relatively earlier than the TVS cooled channel. Both the internal TVS heat exchanger and subcooling the liquid in the propellant tank are shown to significantly improve LAD performance.

  8. Solution of the problems for electromagnetic compatibility in the data acquisition system on the TM-4A device

    International Nuclear Information System (INIS)

    Zasenko, V.A.; Ivkin, V.G.; Trifonov, E.E.

    1984-01-01

    Solution of the problem of electromagnetic compatibility (EMC) in the system of data acquisition for the TM-4A device has a number of peculiarities. The experience in the adjustment and performance of the device permitted to evaluate the significance of the solutions made. It is shown, that protection of recording complex from pulse background noise of general type, appearing at the moment of commutation of powerful energy storages in the power supply system is the main task of EMC ensurance at the tokamak-type devices. At that, it is necessary to take into account all possible ways of background noise propagation, taking protective measures against each of them. The earthing of electronic equipment by the system of protective earthing or power equipment is not a protective measure against background noise, quite the contrary. In devices, operating in a cycle mode the method of gating is the effective means of protection against background noise. The method realization requires works at the early stage of designing

  9. Accumulation of brevetoxins by passive sampling devices | Shea ...

    African Journals Online (AJOL)

    We report on initial investigations into the use of polymer-based passive sampling devices for the chronic time-integrated measure of brevetoxins in natural waters. Polyethylene membranes readily accumulated brevetoxins, but reached steady state within a few days, likely owing to surface saturation on the polyethylene ...

  10. MPS Data Acquisition System

    International Nuclear Information System (INIS)

    Eiseman, S.E.; Miller, W.J.

    1975-01-01

    A description is given of the data acquisition system used with the multiparticle spectrometer facility at Brookhaven. Detailed information is provided on that part of the system which connects the detectors to the data handler; namely, the detector electronics, device controller, and device port optical isolator

  11. Latex Rubber Gloves as a Sampling Dosimeter Using a Novel Surrogate Sampling Device.

    Science.gov (United States)

    Sankaran, Gayatri; Lopez, Terry; Ries, Steve; Ross, John; Vega, Helen; Eastmond, David A; Krieger, Robert I

    2015-01-01

    Pesticide exposure during harvesting of crops occurs primarily to the workers' hands. When harvesters wear latex rubber gloves for personal safety and hygiene harvesting reasons, gloves accumulate pesticide residues. Hence, characterization of the gloves' properties may be useful for pesticide exposure assessments. Controlled field studies were conducted using latex rubber gloves to define the factors that influence the transfer of pesticides to the glove and that would affect their use as a residue monitoring device. A novel sampling device called the Brinkman Contact Transfer Unit (BCTU) was constructed to study the glove characteristics and residue transfer and accumulation under controlled conditions on turf. The effectiveness of latex rubber gloves as sampling dosimeters was evaluated by measuring the transferable pesticide residues as a function of time. The validation of latex rubber gloves as a residue sampling dosimeter was performed by comparing pesticide transfer and dissipation from the gloves, with the turf transferable residues sampled using the validated California (CA) Roller, a standard measure of residue transfer. The observed correlation (Pearson's correlation coefficient R(2)) between the two methods was .84 for malathion and .96 for fenpropathrin, indicating that the BCTU is a useful, reliable surrogate tool for studying available residue transfer to latex rubber gloves under experimental conditions. Perhaps more importantly, these data demonstrate that latex gloves worn by workers may be useful quantifiable matrices for measuring pesticide exposure.

  12. Position-controlled data acquisition embedded system for magnetic NDE of bridge stay cables.

    Science.gov (United States)

    Maldonado-Lopez, Rocio; Christen, Rouven

    2011-01-01

    This work presents a custom-tailored sensing and data acquisition embedded system, designed to be integrated in a new magnetic NDE inspection device under development at Empa, a device intended for routine testing of large diameter bridge stay cables. The data acquisition (DAQ) system fulfills the speed and resolution requirements of the application and is able to continuously capture and store up to 2 GB of data at a sampling rate of 27 kS/s, with 12-bit resolution. This paper describes the DAQ system in detail, including both hardware and software implementation, as well as the key design challenges and the techniques employed to meet the specifications. Experimental results showing the performance of the system are also presented.

  13. Hardware Timestamping for an Image Acquisition System Based on FlexRIO and IEEE 1588 v2 Standard

    Science.gov (United States)

    Esquembri, S.; Sanz, D.; Barrera, E.; Ruiz, M.; Bustos, A.; Vega, J.; Castro, R.

    2016-02-01

    Current fusion devices usually implement distributed acquisition systems for the multiple diagnostics of their experiments. However, each diagnostic is composed by hundreds or even thousands of signals, including images from the vessel interior. These signals and images must be correctly timestamped, because all the information will be analyzed to identify plasma behavior using temporal correlations. For acquisition devices without synchronization mechanisms the timestamp is given by another device with timing capabilities when signaled by the first device. Later, each data should be related with its timestamp, usually via software. This critical action is unfeasible for software applications when sampling rates are high. In order to solve this problem this paper presents the implementation of an image acquisition system with real-time hardware timestamping mechanism. This is synchronized with a master clock using the IEEE 1588 v2 Precision Time Protocol (PTP). Synchronization, image acquisition and processing, and timestamping mechanisms are implemented using Field Programmable Gate Array (FPGA) and a timing card -PTP v2 synchronized. The system has been validated using a camera simulator streaming videos from fusion databases. The developed architecture is fully compatible with ITER Fast Controllers and has been integrated with EPICS to control and monitor the whole system.

  14. Mobile field data acquisition in geosciences

    Science.gov (United States)

    Golodoniuc, Pavel; Klump, Jens; Reid, Nathan; Gray, David

    2016-04-01

    The Discovering Australia's Mineral Resources Program of CSIRO is conducting a study to develop novel methods and techniques to reliably define distal footprints of mineral systems under regolith cover in the Capricorn Orogen - the area that lies between two well-known metallogenic provinces of Pilbara and Yilgarn Cratons in Western Australia. The multidisciplinary study goes beyond the boundaries of a specific discipline and aims at developing new methods to integrate heterogeneous datasets to gain insight into the key indicators of mineralisation. The study relies on large regional datasets obtained from previous hydrogeochemical, regolith, and resistate mineral studies around known deposits, as well as new data obtained from the recent field sampling campaigns around areas of interest. With thousands of water, vegetation, rock and soil samples collected over the past years, it has prompted us to look at ways to standardise field sampling procedures and review the data acquisition process. This process has evolved over the years (Golodoniuc et al., 2015; Klump et al., 2015) and has now reached the phase where fast and reliable collection of scientific data in remote areas is possible. The approach is backed by a unified discipline-agnostic platform - the Federated Archaeological Information Management System (FAIMS). FAIMS is an open source framework for mobile field data acquisition, developed at the University of New South Wales for archaeological field data collection. The FAIMS framework can easily be adapted to a diverse range of scenarios, different kinds of samples, each with its own peculiarities, integration with GPS, and the ability to associate photographs taken with the device embedded camera with captured data. Three different modules have been developed so far, dedicated to geochemical water, plant and rock sampling. All modules feature automatic date and position recording, and reproduce the established data recording workflows. The rock sampling

  15. Comparative study of the characteristics of some suction devices for gas sampling applications

    International Nuclear Information System (INIS)

    Donguy, R.; Drouet, J.

    1959-06-01

    Gas sampling (used to determine the characteristics of dusts or aerosols contained in a gas) needs a suction device. In order to select the right device and the right conditions of use, the characteristics and performances of various suction devices (helicoidal and centrifugal aspirators, air pumps, volumetric pumps) have been experimentally measured: flow rate, head loss, sampling volume and duration, aerosol and dust concentration, gas density, nature of the gas, suction circuit configuration, etc

  16. Space science technology: In-situ science. Sample Acquisition, Analysis, and Preservation Project summary

    Science.gov (United States)

    Aaron, Kim

    1991-01-01

    The Sample Acquisition, Analysis, and Preservation Project is summarized in outline and graphic form. The objective of the project is to develop component and system level technology to enable the unmanned collection, analysis and preservation of physical, chemical and mineralogical data from the surface of planetary bodies. Technology needs and challenges are identified and specific objectives are described.

  17. Evaluation of a new simple collection device for sampling of microparticles in exhaled breath.

    Science.gov (United States)

    Seferaj, Sabina; Ullah, Shahid; Tinglev, Åsa; Carlsson, Sten; Winberg, Jesper; Stambeck, Peter; Beck, Olof

    2018-03-12

    The microparticle fraction of exhaled breath is of interest for developing clinical biomarkers. Exhaled particles may contain non-volatile components from all parts of the airway system, formed during normal breathing. This study aimed to evaluate a new, simple sampling device, based on impaction, for collecting microparticles from exhaled breath. Performance of the new device was compared with that of the existing SensAbues membrane filter device. The analytical work used liquid chromatography-tandem mass spectrometry methods. The new device collected three subsamples and these were separately analysed from eight individuals. No difference was observed between the centre position (0.91 ng/sample) and the side positions (1.01 ng/sample) using major phosphatidylcholine (PC) 16:0/16:0 as the analyte. Exhaled breath was collected from eight patients on methadone maintenance treatment. The intra-individual variability in measured methadone concentration between the three collectors was 8.7%. In another experiment using patients on methadone maintenance treatment, the sampling efficiency was compared with an established filter device. Compared to the existing device, the efficiency of the new device was 121% greater for methadone and 1450% greater for DPPC. The data from lipid analysis also indicated that a larger fraction of the collected material was from the distal parts. Finally, a study using an optical particle counter indicated that the device preferentially collects the larger particle fraction. In conclusion, this study demonstrates the usefulness of the new device for collecting non-volatile components from exhaled breath. The performance of the device was superior to the filter device in several aspects.

  18. Probabilistic Round Trip Contamination Analysis of a Mars Sample Acquisition and Handling Process Using Markovian Decompositions

    Science.gov (United States)

    Hudson, Nicolas; Lin, Ying; Barengoltz, Jack

    2010-01-01

    A method for evaluating the probability of a Viable Earth Microorganism (VEM) contaminating a sample during the sample acquisition and handling (SAH) process of a potential future Mars Sample Return mission is developed. A scenario where multiple core samples would be acquired using a rotary percussive coring tool, deployed from an arm on a MER class rover is analyzed. The analysis is conducted in a structured way by decomposing sample acquisition and handling process into a series of discrete time steps, and breaking the physical system into a set of relevant components. At each discrete time step, two key functions are defined: The probability of a VEM being released from each component, and the transport matrix, which represents the probability of VEM transport from one component to another. By defining the expected the number of VEMs on each component at the start of the sampling process, these decompositions allow the expected number of VEMs on each component at each sampling step to be represented as a Markov chain. This formalism provides a rigorous mathematical framework in which to analyze the probability of a VEM entering the sample chain, as well as making the analysis tractable by breaking the process down into small analyzable steps.

  19. Development and application of a micro-digestion device for biological samples

    International Nuclear Information System (INIS)

    Bohlen, A. von; Klockenkaemper, R.; Messerschmidt, J.; Alt, F.

    2000-01-01

    The analytical characterization of small amounts of a sample is of increasing importance for various research projects in biology, biochemistry and medicine. Reliable determinations of minor and trace elements in microsamples can be performed by total reflection x-ray fluorescence analysis (TXRF). This microanalytical method is suitable for direct multielement analyses of a tiny amount of a liquid or solid sample. Instead of a direct analysis, however, a complete digestion or mineralisation of the sample material prior to analysis can be recommendable. It can be advantageous for a favorable presentation, for a preconcentration and/or homogenization of the material and particularly for an accurate quantification. Unfortunately, commercially available digestion devices are optimized for amounts of 50 to 400 mg of a sample. For smaller amounts, a microdigestion device was constructed and adapted to an equipment of high pressure ashing, which is commercially available. Digestions of very different microsamples between some μg and some mg were carried out, followed by quantitative determinations of a lot of elements. Besides, different Standard Reference Materials (SRM) were analyzed. The homogeneity of these materials could be investigated by comparing the results found for microsamples with those obtained for samples of 200 mg, the latter after digestion in a conventional device. (author)

  20. Device for taking gaseous samples from irradiated fuel elements

    International Nuclear Information System (INIS)

    Lengacker, B.

    1983-01-01

    The described device allows to take gaseous samples from irradiated fuel elements. It is connected with a gas analyzer and a pressure gage, so that in opening the fuel can the internal pressure can be determined

  1. A low-temperature sample orienting device for single crystal spectroscopy at the SNS

    Energy Technology Data Exchange (ETDEWEB)

    Sherline, T E; Solomon, L; Roberts, C K II; Bruce, D; Gaulin, B; Granroth, G E, E-mail: sherlinete@ornl.gov

    2010-11-01

    A low temperature sample orientation device providing three axes of rotation has been successfully built and is in testing for use on several spectrometers at the spallation neutron source (SNS). Sample rotation about the vertical ({omega}) axis of nearly 360 deg. and out of plane tilts ({phi} and v) of from -3.4 deg. to 4.4 deg. and from -2.8 deg. to 3.5 deg., respectively, are possible. An off-the-shelf closed cycle refrigerator (CCR) is mounted on a room temperature sealed rotary flange providing {omega} rotations of the sample. Out-of-plane tilts are made possible by piezoelectric actuated angular positioning devices mounted on the low temperature head of the CCR. Novel encoding devices based on magnetoresistive sensors have been developed to measure the tilt stage angles. This combination facilitates single crystal investigations from room temperature to 3.1 K. Commissioning experiments of the rotating CCR for both powder and single crystal samples have been performed on the ARCS spectrometer at the SNS. For the powder sample this device was used to continuously rotate the sample and thus average out any partial orientation of the powder. The powder rings observed in S(Q) are presented. For the single crystal sample, the rotation was used to probe different regions of momentum transfer (Q-space). Laue patterns obtained from a single crystal sample at two rotation angles are presented.

  2. On the optimal sampling of bandpass measurement signals through data acquisition systems

    International Nuclear Information System (INIS)

    Angrisani, L; Vadursi, M

    2008-01-01

    Data acquisition systems (DAS) play a fundamental role in a lot of modern measurement solutions. One of the parameters characterizing a DAS is its maximum sample rate, which imposes constraints on the signals that can be alias-free digitized. Bandpass sampling theory singles out separated ranges of admissible sample rates, which can be significantly lower than carrier frequency. But, how to choose the most convenient sample rate according to the purpose at hand? The paper proposes a method for the automatic selection of the optimal sample rate in measurement applications involving bandpass signals; the effects of sample clock instability and limited resolution are also taken into account. The method allows the user to choose the location of spectral replicas of the sampled signal in terms of normalized frequency, and the minimum guard band between replicas, thus introducing a feature that no DAS currently available on the market seems to offer. A number of experimental tests on bandpass digitally modulated signals are carried out to assess the concurrence of the obtained central frequency with the expected one

  3. A novel needle-type sampling device for flexible ultrathin bronchoscopy

    International Nuclear Information System (INIS)

    Suda, Yuji; Hayashi, Katsutoshi; Shindoh, Yuriko; Iijima, Hideya; Tanaka, Akiko

    2008-01-01

    Diagnosis of suspected cancer in the periphery of the lung is difficult. A flexible ultrathin bronchoscope has been developed for the diagnosis of peripherally located pulmonary lesions that cannot be reached with the sampling devices for standard flexible bronchoscopes. The diagnostic yield with forceps and a brush for ultrathin bronchoscopes, however, is not adequate, especially when a lesion is not exposed to the bronchial lumen. We have thus developed a novel needle-type sampling device and tested its yield in transbronchial cytology. The device consists of an elongated dental H-file (0.4 mm in diameter and 110 cm in length), a housing sheath (1.0 mm in outer diameter), and a novel handle, which enables rapid out-and-in motion of the needle. Ten consecutive patients with a peripheral pulmonary lesion who had an indication for diagnostic procedure with a flexible ultrathin bronchoscope were enrolled. The optimal bronchial route to the lesion was analyzed with virtual bronchoscopy in a data set obtained with high-resolution computed tomography, and a novel bronchial route labeling system (prior-ridge-based relative orientation nomenclature) was employed to guide insertion of the bronchoscope. Sampling with the novel needle was performed prior to use of the forceps and brush under conventional fluoroscopy. In all the cases, sampling with the needle was successful and the amount of the specimen was sufficient for cytology. Our novel sampling system with flexible ultrathin bronchoscopes may contribute to accurate and minimally invasive diagnosis of peripheral pulmonary lesions. (author)

  4. Application of HDF5 in long-pulse quasi-steady state data acquisition at high sampling rate

    International Nuclear Information System (INIS)

    Chen, Y.; Wang, F.; Li, S.; Xiao, B.J.; Yang, F.

    2014-01-01

    Highlights: • The new data-acquisition system supports long-pulse EAST data acquisition. • The new data-acquisition system is capable for most of the high frequency signals of EAST experiments. • The system's total throughput is about 500 MB/s. • The system uses HDF5 to store data. - Abstract: A new high sampling rate quasi-steady state data-acquisition system has been designed for the microwave reflectometry diagnostic of EAST experiments. In order to meet the requirements of long-pulse discharge and high sampling rate, it is designed based on PXI Express technology. A high-performance digitizer National Instruments PXIe-5122 with two synchronous analog input channels in which the maximum sampling rate is 100 MHz has been adopted. Two PXIe-5122 boards at 60 MSPS and one PXIe-6368 board at 2 MSPS are used in the system and the total throughput is about 500 MB/s. To guarantee the large amounts of data being saved continuously in the long-pulse discharge, an external hard-disk data stream enclosure NI HDD-8265 in which the capacity of sustained speed of reading and writing is 700 MB/s. And in RAID-5 mode its storage capacity is 80% of the total. The obtained raw data firstly stream continuously into NI HDD-8265 during the discharge. Then it will be transferred to the data server automatically and converted into HDF5 file format. HDF5 is an open source file format for data storage and management which has been widely used in various fields, and suitable for long term case. The details of the system are described in the paper

  5. Microfluidic devices for sample preparation and rapid detection of foodborne pathogens.

    Science.gov (United States)

    Kant, Krishna; Shahbazi, Mohammad-Ali; Dave, Vivek Priy; Ngo, Tien Anh; Chidambara, Vinayaka Aaydha; Than, Linh Quyen; Bang, Dang Duong; Wolff, Anders

    2018-03-10

    Rapid detection of foodborne pathogens at an early stage is imperative for preventing the outbreak of foodborne diseases, known as serious threats to human health. Conventional bacterial culturing methods for foodborne pathogen detection are time consuming, laborious, and with poor pathogen diagnosis competences. This has prompted researchers to call the current status of detection approaches into question and leverage new technologies for superior pathogen sensing outcomes. Novel strategies mainly rely on incorporating all the steps from sample preparation to detection in miniaturized devices for online monitoring of pathogens with high accuracy and sensitivity in a time-saving and cost effective manner. Lab on chip is a blooming area in diagnosis, which exploits different mechanical and biological techniques to detect very low concentrations of pathogens in food samples. This is achieved through streamlining the sample handling and concentrating procedures, which will subsequently reduce human errors and enhance the accuracy of the sensing methods. Integration of sample preparation techniques into these devices can effectively minimize the impact of complex food matrix on pathogen diagnosis and improve the limit of detections. Integration of pathogen capturing bio-receptors on microfluidic devices is a crucial step, which can facilitate recognition abilities in harsh chemical and physical conditions, offering a great commercial benefit to the food-manufacturing sector. This article reviews recent advances in current state-of-the-art of sample preparation and concentration from food matrices with focus on bacterial capturing methods and sensing technologies, along with their advantages and limitations when integrated into microfluidic devices for online rapid detection of pathogens in foods and food production line. Copyright © 2018. Published by Elsevier Inc.

  6. Microfluidic devices for sample preparation and rapid detection of foodborne pathogens

    DEFF Research Database (Denmark)

    Kant, Krishna; Shahbazi, Mohammad-Ali; Dave, Vivek Priy

    2018-01-01

    and improve the limit of detections. Integration of pathogen capturing bio-receptors on microfluidic devices is a crucial step, which can facilitate recognition abilities in harsh chemical and physical conditions, offering a great commercial benefit to the food-manufacturing sector. This article reviews...... diagnosis competences. This has prompted researchers to call the current status of detection approaches into question and leverage new technologies for superior pathogen sensing outcomes. Novel strategies mainly rely on incorporating all the steps from sample preparation to detection in miniaturized devices...... recent advances in current state-of-the-art of sample preparation and concentration from food matrices with focus on bacterial capturing methods and sensing technologies, along with their advantages and limitations when integrated into microfluidic devices for online rapid detection of pathogens in foods...

  7. 78 FR 27442 - Coal Mine Dust Sampling Devices; Correction

    Science.gov (United States)

    2013-05-10

    ... DEPARTMENT OF LABOR Mine Safety and Health Administration Coal Mine Dust Sampling Devices; Correction AGENCY: Mine Safety and Health Administration, Labor. ACTION: Notice; correction. SUMMARY: On April 30, 2013, Mine Safety and Health Administration (MSHA) published a notice in the Federal Register...

  8. Distributed processing and network of data acquisition and diagnostics control for Large Helical Device (LHD)

    International Nuclear Information System (INIS)

    Nakanishi, H.; Kojima, M.; Hidekuma, S.

    1997-11-01

    The LHD (Large Helical Device) data processing system has been designed in order to deal with the huge amount of diagnostics data of 600-900 MB per 10-second short-pulse experiment. It prepares the first plasma experiment in March 1998. The recent increase of the data volume obliged to adopt the fully distributed system structure which uses multiple data transfer paths in parallel and separates all of the computer functions into clients and servers. The fundamental element installed for every diagnostic device consists of two kinds of server computers; the data acquisition PC/Windows NT and the real-time diagnostics control VME/VxWorks. To cope with diversified kinds of both device control channels and diagnostics data, the object-oriented method are utilized wholly for the development of this system. It not only reduces the development burden, but also widen the software portability and flexibility. 100Mbps EDDI-based fast networks will re-integrate the distributed server computers so that they can behave as one virtual macro-machine for users. Network methods applied for the LHD data processing system are completely based on the TCP/IP internet technology, and it provides the same accessibility to the remote collaborators as local participants can operate. (author)

  9. Data acquisition upgrade in the RFX experiment

    International Nuclear Information System (INIS)

    Barana, O.; Luchetta, A.; Manduchi, G.; Taliercio, C.

    2005-01-01

    The control and data acquisition system of RFX has been completely renewed and is currently under re-commissioning. Most data acquisition is now performed by means of CompactPCI (CPCI) devices supervised by Pentium PCs running Linux. Real-time control systems, implemented using VME and PowerPCs running VxWorks, also produce data that are then acquired by the data acquisition system. The older CAMAC systems have only been retained for existing diagnostics. New diagnostic systems will employ either CompactPCI data acquisition or custom solutions, usually running under Windows, due to the fact that the drivers for the used devices are normally available for this platform. Despite the variety of hardware and software platforms involved in data acquisition, the same software package is used for all components, thus providing a uniform view of the system. Such functionality is provided by the MDSplus software. MDSplus is now available for a variety of platforms, and includes several Java components that are platform-independent

  10. Bio-sample detection on paper-based devices with inkjet printer-sprayed reagents.

    Science.gov (United States)

    Liang, Wun-Hong; Chu, Chien-Hung; Yang, Ruey-Jen

    2015-12-01

    The reagent required for bio-sample detection on paper-based analytical devices is generally introduced manually using a pipette. Such an approach is time-consuming; particularly if a large number of devices are required. Automated methods provide a far more convenient solution for large-scale production, but incur a substantial cost. Accordingly, the present study proposes a low-cost method for the paper-based analytical devices in which the biochemical reagents are sprayed onto the device directly using a modified commercial inkjet printer. The feasibility of the proposed method is demonstrated by performing aspartate aminotransferase (AST) and alanine aminotransferase (ALT) tests using simple two-dimensional (2D) paper-based devices. In both cases, the reaction process is analyzed using an image-processing-based colorimetric method. The experimental results show that for AST detection within the 0-105 U/l concentration range, the optimal observation time is around four minutes, while for ALT detection in the 0-125 U/l concentration range, the optimal observation time is approximately one minute. Finally, for both samples, the detection performance of the sprayed-reagent analytical devices is insensitive to the glucose concentration. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Accurate Sample Time Reconstruction of Inertial FIFO Data

    Directory of Open Access Journals (Sweden)

    Sebastian Stieber

    2017-12-01

    Full Text Available In the context of modern cyber-physical systems, the accuracy of underlying sensor data plays an increasingly important role in sensor data fusion and feature extraction. The raw events of multiple sensors have to be aligned in time to enable high quality sensor fusion results. However, the growing number of simultaneously connected sensor devices make the energy saving data acquisition and processing more and more difficult. Hence, most of the modern sensors offer a first-in-first-out (FIFO interface to store multiple data samples and to relax timing constraints, when handling multiple sensor devices. However, using the FIFO interface increases the negative influence of individual clock drifts—introduced by fabrication inaccuracies, temperature changes and wear-out effects—onto the sampling data reconstruction. Furthermore, additional timing offset errors due to communication and software latencies increases with a growing number of sensor devices. In this article, we present an approach for an accurate sample time reconstruction independent of the actual clock drift with the help of an internal sensor timer. Such timers are already available in modern sensors, manufactured in micro-electromechanical systems (MEMS technology. The presented approach focuses on calculating accurate time stamps using the sensor FIFO interface in a forward-only processing manner as a robust and energy saving solution. The proposed algorithm is able to lower the overall standard deviation of reconstructed sampling periods below 40 μ s, while run-time savings of up to 42% are achieved, compared to single sample acquisition.

  12. Polymeric ionic liquid-based portable tip microextraction device for on-site sample preparation of water samples.

    Science.gov (United States)

    Chen, Lei; Pei, Junxian; Huang, Xiaojia; Lu, Min

    2018-06-05

    On-site sample preparation is highly desired because it avoids the transportation of large-volume samples and ensures the accuracy of the analytical results. In this work, a portable prototype of tip microextraction device (TMD) was designed and developed for on-site sample pretreatment. The assembly procedure of TMD is quite simple. Firstly, polymeric ionic liquid (PIL)-based adsorbent was in-situ prepared in a pipette tip. After that, the tip was connected with a syringe which was driven by a bidirectional motor. The flow rates in adsorption and desorption steps were controlled accurately by the motor. To evaluate the practicability of the developed device, the TMD was used to on-site sample preparation of waters and combined with high-performance liquid chromatography with diode array detection to measure trace estrogens in water samples. Under the most favorable conditions, the limits of detection (LODs, S/N = 3) for the target analytes were in the range of 4.9-22 ng/L, with good coefficients of determination. Confirmatory study well evidences that the extraction performance of TMD is comparable to that of the traditional laboratory solid-phase extraction process, but the proposed TMD is more simple and convenient. At the same time, the TMD avoids complicated sampling and transferring steps of large-volume water samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Development of gas-sampling device for 13N monitoring system

    International Nuclear Information System (INIS)

    Zhao Lihong; Gong Xueyu

    2003-01-01

    The 13 N monitoring system is used in the monitoring of the rate of leakage of the primary coolant circuit in nuclear power stations. The author introduces a gas-sampling device of the 13 Nmonitoring system. It is with a close-loop flow control system with intelligent control of Single Chip Micyoco (SCM), and has the ability to monitor and replace the filter paper automatically, to increase the automation of the device and stable operation in long time

  14. FISHprep: A Novel Integrated Device for Metaphase FISH Sample Preparation

    DEFF Research Database (Denmark)

    Shah, Pranjul Jaykumar; Vedarethinam, Indumathi; Kwasny, Dorota

    2011-01-01

    We present a novel integrated device for preparing metaphase chromosomes spread slides (FISHprep). The quality of cytogenetic analysis from patient samples greatly relies on the efficiency of sample pre-treatment and/or slide preparation. In cytogenetic slide preparation, cell cultures...... are routinely used to process samples (for culture, arrest and fixation of cells) and/or to expand limited amount of samples (in case of prenatal diagnostics). Arguably, this expansion and other sample pretreatments form the longest part of the entire diagnostic protocols spanning over 3–4 days. We present here...... with minimal handling for metaphase FISH slide preparation....

  15. Device to investigate samples by means of flameless atomic absorption measurement

    International Nuclear Information System (INIS)

    Sperling, K.R.

    1977-01-01

    An improvement on a device to investigate samples by means of flameless atomic absorption measurement is suggested in which one aims to produce a most complete possible atomic clond from the sample to be investigated within the sample space defined by the beam bundle, through which the measuring beam bundle is passed. According to the invention, the tubular sample space should be closed by an optically penetrable window on one side. (RW) [de

  16. A core handling device for the Mars Sample Return Mission

    Science.gov (United States)

    Gwynne, Owen

    1989-01-01

    A core handling device for use on Mars is being designed. To provide a context for the design study, it was assumed that a Mars Rover/Sample Return (MRSR) Mission would have the following characteristics: a year or more in length; visits by the rover to 50 or more sites; 100 or more meter-long cores being drilled by the rover; and the capability of returning about 5 kg of Mars regolith to Earth. These characteristics lead to the belief that in order to bring back a variegated set of samples that can address the range of scientific objetives for a MRSR mission to Mars there needs to be considerable analysis done on board the rover. Furthermore, the discrepancy between the amount of sample gathered and the amount to be returned suggests that there needs to be some method of choosing the optimal set of samples. This type of analysis will require pristine material-unaltered by the drilling process. Since the core drill thermally and mechanically alters the outer diameter (about 10 pct) of the core sample, this outer area cannot be used. The primary function of the core handling device is to extract subsamples from the core and to position these subsamples, and the core itself if needed, with respect to the various analytical instruments that can be used to perform these analyses.

  17. Development of a Novel Self-Enclosed Sample Preparation Device for DNA/RNA Isolation in Space

    Science.gov (United States)

    Zhang, Ye; Mehta, Satish K.; Pensinger, Stuart J.; Pickering, Karen D.

    2011-01-01

    Modern biology techniques present potentials for a wide range of molecular, cellular, and biochemistry applications in space, including detection of infectious pathogens and environmental contaminations, monitoring of drug-resistant microbial and dangerous mutations, identification of new phenotypes of microbial and new life species. However, one of the major technological blockades in enabling these technologies in space is a lack of devices for sample preparation in the space environment. To overcome such an obstacle, we constructed a prototype of a DNA/RNA isolation device based on our novel designs documented in the NASA New Technology Reporting System (MSC-24811-1/3-1). This device is self-enclosed and pipette free, purposely designed for use in the absence of gravity. Our design can also be modified easily for preparing samples in space for other applications, such as flowcytometry, immunostaining, cell separation, sample purification and separation according to its size and charges, sample chemical labeling, and sample purification. The prototype of our DNA/RNA isolation device was tested for efficiencies of DNA and RNA isolation from various cell types for PCR analysis. The purity and integrity of purified DNA and RNA were determined as well. Results showed that our developed DNA/RNA isolation device offers similar efficiency and quality in comparison to the samples prepared using the standard protocol in the laboratory.

  18. Biological samples positioning device for irradiations on a radial channel at the nuclear research reactor

    International Nuclear Information System (INIS)

    Rodriguez Gual, Maritza; Mas Milian, Felix; Deppman, Airton; Pinto Coelho, Paulo Rogerio

    2010-01-01

    For the demand of an experimental device for biological samples positioning system for irradiations on a radial channel at the nuclear research reactor in operation was constructed and started up a device for the place and remove of the biological samples from the irradiation channels without interrupting the operation of the reactor. The economical valuations are effected comparing with another type of device with the same functions. This work formed part of an international project between Cuba and Brazil that undertook the study of the induced damages by various types of ionizing radiation in DNA molecules. Was experimentally tested the proposed solution, which demonstrates the practical validity of the device. As a result of the work, the experimental device for biological samples irradiations are installed and operating in the radial beam hole No3(BH3) for more than five years at the IEA-R1 Brazilian research reactor according to the solicited requirements the device. The designed device increases considerably the type of studies can be conducted in this reactor. Its practical application in research taking place in that facility, in the field of radiobiology and dosimetry, and so on is immediate

  19. Methods and devices for hyperpolarising and melting NMR samples in a cryostat

    DEFF Research Database (Denmark)

    Ardenkjaer-Larsen, Jan Henrik; Axelsson, Oskar H. E.; Golman, Klaes Koppel

    2006-01-01

    The present invention relates to devices and method for melting solid polarised sample while retaining a high level of polarisation. In an embodiment of the present invention a sample is polarised in a sample-retaining cup 9 in a strong magnetic field in a polarising means 3a, 3b, 3c in a cryosta...

  20. Development of data acquisition system for tracing fast flow using GPIB

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Bum; Jung, Sung Hee

    2003-12-01

    Radiotracer data acquisition system which was developed by radiotracer group in Korea Atomic Energy Research Institute has been used for field experiment since the late of 1990s. It has RS232C and 24 channel x10 sample. It was useful for radiotracer experiment whose period span from few second to few ten days. But the demand for tracing fast flow has been increasing. For example, to trace a fast gas flow in petro chemical industry or for application like computer aided radioactive particle tracking, high speed data acquisition system is necessary. The current commercial data acquisition systems have limited count channels. To solve above mentioned problem upgraded high speed data acquisition system using GPIB is developed. GPIB system is one method of control and communication. The data transmit speed of GPIB is 200k byte/sec which is faster then 20k bps of RS232C. In addition to that, GPIB has advantage of expanding up to 15 devices. It mean that 24 x15 channel is possible if one device has 24channel. It make possible to trace high fast flow or large number of channel. This technical report include details of the design of high speed multi-channel radiation detecting system which is consist of ratemeter module, display unit, mainboard with GPIB system and 24 channel counter board. The design of GPIB system developed here is also applicable to other measurement system for various applications.

  1. Development of data acquisition system for tracing fast flow using GPIB

    International Nuclear Information System (INIS)

    Kim, Jong Bum; Jung, Sung Hee

    2003-12-01

    Radiotracer data acquisition system which was developed by radiotracer group in Korea Atomic Energy Research Institute has been used for field experiment since the late of 1990s. It has RS232C and 24 channel x10 sample. It was useful for radiotracer experiment whose period span from few second to few ten days. But the demand for tracing fast flow has been increasing. For example, to trace a fast gas flow in petro chemical industry or for application like computer aided radioactive particle tracking, high speed data acquisition system is necessary. The current commercial data acquisition systems have limited count channels. To solve above mentioned problem upgraded high speed data acquisition system using GPIB is developed. GPIB system is one method of control and communication. The data transmit speed of GPIB is 200k byte/sec which is faster then 20k bps of RS232C. In addition to that, GPIB has advantage of expanding up to 15 devices. It mean that 24 x15 channel is possible if one device has 24channel. It make possible to trace high fast flow or large number of channel. This technical report include details of the design of high speed multi-channel radiation detecting system which is consist of ratemeter module, display unit, mainboard with GPIB system and 24 channel counter board. The design of GPIB system developed here is also applicable to other measurement system for various applications

  2. Evaluation of high performance data acquisition boards for simultaneous sampling of fast signals from PET detectors

    International Nuclear Information System (INIS)

    Judenhofer, Martin S; Pichler, Bernd J; Cherry, Simon R

    2005-01-01

    Detectors used for positron emission tomography (PET) provide fast, randomly distributed signals that need to be digitized for further processing. One possibility is to sample the signals at the peak initiated by a trigger from a constant fraction discriminator (CFD). For PET detectors, simultaneous acquisition of many channels is often important. To develop and evaluate novel PET detectors, a flexible, relatively low cost and high performance laboratory data acquisition (DAQ) system is therefore required. The use of dedicated DAQ systems, such as a multi-channel analysers (MCAs) or continuous sampling boards at high rates, is expensive. This work evaluates the suitability of well-priced peripheral component interconnect (PCI)-based 8-channel DAQ boards (PD2-MFS-8 2M/14 and PD2-MFS-8-500k/14, United Electronic Industries Inc., Canton, MA, USA) for signal acquisition from novel PET detectors. A software package was developed to access the board, measure basic board parameters, and to acquire, visualize, and analyse energy spectra and position profiles from block detectors. The performance tests showed that the boards input linearity is >99.2% and the standard deviation is 22 Na source was 14.9% (FWHM) at 511 keV and is slightly better than the result obtained with a high-end single channel MCA (8000A, Amptek, USA) using the same detector (16.8%). The crystals (1.2 x 1.2 x 12 mm 3 ) within a 9 x 9 LSO block detector could be clearly separated in an acquired position profile. Thus, these boards are well suited for data acquisition with novel detectors developed for nuclear imaging

  3. Improvement of digital data acquisition system in reflood test rig

    International Nuclear Information System (INIS)

    Sudoh, Takashi; Murao, Yoshio; Niitsuma, Yasushi

    1979-03-01

    The original master digital data acquisition system was designed to collect 30 channels of analog data rapidly and convert them into digital form for recording on a magnetic tape. Due to the increases in the number of channels and the ranges of measurement, an additional acquisition device was needed for the original system. This report descrives the design of the additional data acquisition device and the results of performance tests. The operational manual is attached as an appendix. It was confirmed that the new system satisfied the requirements of system. (author)

  4. An unattended device for high-voltage sampling and passive measurement of thoron decay products

    Energy Technology Data Exchange (ETDEWEB)

    Gierl, Stefanie; Meisenberg, Oliver, E-mail: oliver.meisenberg@helmholtz-muenchen.de; Wielunski, Marek; Tschiersch, Jochen [Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Radiation Protection, Ingolstädter Landstr. 1, 85764 Neuherberg (Germany); Haninger, Thomas [Helmholtz Zentrum München, German Research Center for Environmental Health, Auswertungsstelle für Strahlendosimeter, Otto-Hahn-Ring 6, 81739 München (Germany)

    2014-02-15

    An integrating measurement device for the concentration of airborne thoron decay products was designed and calibrated. It is suitable for unattended use over up to several months also in inhabited dwellings. The device consists of a hemispheric capacitor with a wire mesh as the outer electrode on ground potential and the sampling substrates as the inner electrode on +7.0 kV. Negatively charged and neutral thoron decay products are accelerated to and deposited on the sampling substrates. As sampling substrates, CR39 solid-state nuclear track detectors are used in order to record the alpha decay of the sampled decay products. Nuclide discrimination is achieved by covering the detectors with aluminum foil of different thickness, which are penetrated only by alpha particles with sufficient energy. Devices of this type were calibrated against working level monitors in a thoron experimental house. The sensitivity was measured as 9.2 tracks per Bq/m{sup 3} × d of thoron decay products. The devices were used over 8 weeks in several houses built of earthen material in southern Germany, where equilibrium equivalent concentrations of 1.4–9.9 Bq/m{sup 3} of thoron decay products were measured.

  5. Applying Rapid Acquisition Policy Lessons for Defense Innovation

    Science.gov (United States)

    2017-12-21

    import- ing Silicon Valley- style innovation practices to its acquisition process, it is im- portant to assess an organization’s ability to...these efforts. Keywords: defense acquisition, defense procurement, rapid acquisition, de- fense innovation, program management , organizational culture...Device De- feat Organization, JIEDDO, Rapid Equipping Force, REF Silicon Valley- style innovation is a hot topic in the Department of De-fense (DOD). For

  6. Architecture of an acquisition system-multiprocessors

    International Nuclear Information System (INIS)

    Postec, H.

    1987-07-01

    To follow the huge increasing of concerned parameters in nuclear detection systems, acquisition systems become bigger and have to present very good rapidity performance. At Ganil, four detection systems have been set in Nautilus reaction chamber, that lead to experiment configurations with 700 parameters to process. In front of present acquisition system limitation, a device more relevant to lecture of a large number of channels show off necessary. Functionalities already operating in other systems and hardware already used have been chosen; specific technical solutions were aldo developed to use the most recent techniques and to take in account the four detection system structure of the device [fr

  7. Application of an ultrasonic focusing radiator for acoustic levitation of submillimeter samples

    Science.gov (United States)

    Lee, M. C.

    1981-01-01

    An acoustic apparatus has been specifically developed to handle samples of submillimeter size in a gaseous medium. This apparatus consists of an acoustic levitation device, deployment devices for small liquid and solid samples, heat sources for sample heat treatment, acoustic alignment devices, a cooling system and data-acquisition instrumentation. The levitation device includes a spherical aluminum dish of 12 in. diameter and 0.6 in. thickness, 130 pieces of PZT transducers attached to the back side of the dish and a spherical concave reflector situated in the vicinity of the center of curvature of the dish. The three lowest operating frequencies for the focusing-radiator levitation device are 75, 105 and 163 kHz, respectively. In comparison with other levitation apparatus, it possesses a large radiation pressure and a high lateral positional stability. This apparatus can be used most advantageously in the study of droplets and spherical shell systems, for instance, for fusion target applications.

  8. Use of passive sampling devices to determine soil contaminant concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, K.A. [Clemson Univ., Pendleton, SC (United States)]|[Washington State Univ., Richland, WA (United States); Hooper, M.J. [Clemson Univ., Pendleton, SC (United States); Weisskopf, C.P. [Washington State Univ., Richland, WA (United States)

    1996-12-31

    The effective remediation of contaminated sites requires accurate identification of chemical distributions. A rapid sampling method using passive sampling devices (PSDs) can provide a thorough site assessment. We have been pursuing their application in terrestrial systems and have found that they increase the ease and speed of analysis, decrease solvent usage and overall cost, and minimize the transport of contaminated soils. Time and cost savings allow a higher sampling frequency than is generally the case using traditional methods. PSDs have been used in the field in soils of varying physical properties and have been successful in estimating soil concentrations ranging from 1 {mu}g/kg (parts per billion) to greater than 200 mg/kg (parts per million). They were also helpful in identifying hot spots within the sites. Passive sampling devices show extreme promise as an analytical tool to rapidly characterize contaminant distributions in soil. There are substantial time and cost savings in laboratory personnel and supplies. By selectively excluding common interferences that require sample cleanup, PSDs can be retrieved from the field and processed rapidly (one technician can process approximately 90 PSDs in an 8-h work day). The results of our studies indicate that PSDs can be used to accurately estimate soil contaminant concentrations and provide lower detection limits. Further, time and cost savings will allow a more thorough and detailed characterization of contaminant distributions. 13 refs., 4 figs., 2 tabs.

  9. Design of area array CCD image acquisition and display system based on FPGA

    Science.gov (United States)

    Li, Lei; Zhang, Ning; Li, Tianting; Pan, Yue; Dai, Yuming

    2014-09-01

    With the development of science and technology, CCD(Charge-coupled Device) has been widely applied in various fields and plays an important role in the modern sensing system, therefore researching a real-time image acquisition and display plan based on CCD device has great significance. This paper introduces an image data acquisition and display system of area array CCD based on FPGA. Several key technical challenges and problems of the system have also been analyzed and followed solutions put forward .The FPGA works as the core processing unit in the system that controls the integral time sequence .The ICX285AL area array CCD image sensor produced by SONY Corporation has been used in the system. The FPGA works to complete the driver of the area array CCD, then analog front end (AFE) processes the signal of the CCD image, including amplification, filtering, noise elimination, CDS correlation double sampling, etc. AD9945 produced by ADI Corporation to convert analog signal to digital signal. Developed Camera Link high-speed data transmission circuit, and completed the PC-end software design of the image acquisition, and realized the real-time display of images. The result through practical testing indicates that the system in the image acquisition and control is stable and reliable, and the indicators meet the actual project requirements.

  10. Experience-Sampling Methodology with a Mobile Device in Fibromyalgia

    Directory of Open Access Journals (Sweden)

    Castilla Diana

    2012-01-01

    Full Text Available This work describes the usability studies conducted in the development of an experience-sampling methodology (ESM system running in a mobile device. The goal of the system is to improve the accuracy and ecology in gathering daily self-report data in individuals suffering a chronic pain condition, fibromyalgia. The usability studies showed that the developed software to conduct ESM with mobile devices (smartphones, cell phones can be successfully used by individuals with fibromyalgia of different ages and with low level of expertise in the use of information and communication technologies. 100% of users completed the tasks successfully, although some have completely illiterate. Also there seems to be a clear difference in the way of interaction obtained in the two studies carried out.

  11. Large - scale Rectangular Ruler Automated Verification Device

    Science.gov (United States)

    Chen, Hao; Chang, Luping; Xing, Minjian; Xie, Xie

    2018-03-01

    This paper introduces a large-scale rectangular ruler automated verification device, which consists of photoelectric autocollimator and self-designed mechanical drive car and data automatic acquisition system. The design of mechanical structure part of the device refer to optical axis design, drive part, fixture device and wheel design. The design of control system of the device refer to hardware design and software design, and the hardware mainly uses singlechip system, and the software design is the process of the photoelectric autocollimator and the automatic data acquisition process. This devices can automated achieve vertical measurement data. The reliability of the device is verified by experimental comparison. The conclusion meets the requirement of the right angle test procedure.

  12. Design of sample analysis device for iodine adsorption efficiency test in NPPs

    International Nuclear Information System (INIS)

    Ji Jinnan

    2015-01-01

    In nuclear power plants, iodine adsorption efficiency test is used to check the iodine adsorption efficiency of the iodine adsorber. The iodine adsorption efficiency can be calculated through the analysis of the test sample, and thus to determine if the performance of the adsorber meets the requirement on the equipment operation and emission. Considering the process of test and actual demand, in this paper, a special device for the analysis of this kind of test sample is designed. The application shows that the device is with convenient operation and high reliability and accurate calculation, and improves the experiment efficiency and reduces the experiment risk. (author)

  13. Male Circumcision and STI Acquisition in Britain: Evidence from a National Probability Sample Survey.

    Directory of Open Access Journals (Sweden)

    Virginia Homfray

    Full Text Available It is well-established that male circumcision reduces acquisition of HIV, herpes simplex virus 2, chancroid, and syphilis. However, the effect on the acquisition of non-ulcerative sexually transmitted infections (STIs remains unclear. We examined the relationship between circumcision and biological measures of three STIs: human papillomavirus (HPV, Chlamydia trachomatis and Mycoplasma genitalium.A probability sample survey of 15,162 men and women aged 16-74 years (including 4,060 men aged 16-44 years was carried out in Britain between 2010 and 2012. Participants completed a computer-assisted personal interview, including a computer-assisted self-interview, which asked about experience of STI diagnoses, and circumcision. Additionally, 1,850 urine samples from sexually-experienced men aged 16-44 years were collected and tested for STIs. Multivariable logistic regression was used to calculate adjusted odds ratios (AOR to quantify associations between circumcision and i self-reporting any STI diagnosis and ii presence of STIs in urine, in men aged 16-44 years, adjusting for key socio-demographic and sexual behavioural factors.The prevalence of circumcision in sexually-experienced men aged 16-44 years was 17.4% (95%CI 16.0-19.0. There was no association between circumcision and reporting any previous STI diagnoses, and specifically previous chlamydia or genital warts. However, circumcised men were less likely to have any HPV type (AOR 0.26, 95% confidence interval (CI 0.13-0.50 including high-risk HPV types (HPV-16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59 and/or 68 (AOR 0.14, 95% CI 0.05-0.40 detected in urine.Circumcised men had reduced odds of HPV detection in urine. These findings have implications for improving the precision of models of STI transmission in populations with different circumcision prevalence and in designing interventions to reduce STI acquisition.

  14. Real-time data acquisition and processing platform for fusion experiments

    International Nuclear Information System (INIS)

    Ruiz, M.; Barrera, E.; Lopez, S.; Machon, D.; Vega, J.; Sanchez, E.

    2004-01-01

    This paper describes the features of the hardware and low-level software of the PXI real-time data acquisition and processing system developed for the TJ-II device located in the Centro de Investigaciones Energeticas Medioambientales y Tecnologicas (CIEMAT) in Madrid. This system fulfills three objectives: (1) to increase processing capabilities of standard data acquisition systems by adding specific processing cards, (2) to acquire and process data in real time with a view to deployment on steady state fusion devices, and (3) to develop the data acquisition and processing applications using graphical languages like LabView

  15. Multi-channel data acquisition system with absolute time synchronization

    Science.gov (United States)

    Włodarczyk, Przemysław; Pustelny, Szymon; Budker, Dmitry; Lipiński, Marcin

    2014-11-01

    We present a low-cost, stand-alone global-time-synchronized data acquisition system. Our prototype allows recording up to four analog signals with a 16-bit resolution in variable ranges and a maximum sampling rate of 1000 S/s. The system simultaneously acquires readouts of external sensors e.g. magnetometer or thermometer. A complete data set, including a header containing timestamp, is stored on a Secure Digital (SD) card or transmitted to a computer using Universal Serial Bus (USB). The estimated time accuracy of the data acquisition is better than ±200 ns. The device is intended for use in a global network of optical magnetometers (the Global Network of Optical Magnetometers for Exotic physics - GNOME), which aims to search for signals heralding physics beyond the Standard Model, that can be generated by ordinary spin coupling to exotic particles or anomalous spin interactions.

  16. A method to synchronize signals from multiple patient monitoring devices through a single input channel for inclusion in list-mode acquisitions

    International Nuclear Information System (INIS)

    O’Connor, J. Michael; Pretorius, P. Hendrik; Johnson, Karen; King, Michael A.

    2013-01-01

    Purpose: This technical note documents a method that the authors developed for combining a signal to synchronize a patient-monitoring device with a second physiological signal for inclusion into list-mode acquisition. Our specific application requires synchronizing an external patient motion-tracking system with a medical imaging system by multiplexing the tracking input with the ECG input. The authors believe that their methodology can be adapted for use in a variety of medical imaging modalities including single photon emission computed tomography (SPECT) and positron emission tomography (PET). Methods: The authors insert a unique pulse sequence into a single physiological input channel. This sequence is then recorded in the list-mode acquisition along with the R-wave pulse used for ECG gating. The specific form of our pulse sequence allows for recognition of the time point being synchronized even when portions of the pulse sequence are lost due to collisions with R-wave pulses. This was achieved by altering our software used in binning the list-mode data to recognize even a portion of our pulse sequence. Limitations on heart rates at which our pulse sequence could be reliably detected were investigated by simulating the mixing of the two signals as a function of heart rate and time point during the cardiac cycle at which our pulse sequence is mixed with the cardiac signal. Results: The authors have successfully achieved accurate temporal synchronization of our motion-tracking system with acquisition of SPECT projections used in 17 recent clinical research cases. In our simulation analysis the authors determined that synchronization to enable compensation for body and respiratory motion could be achieved for heart rates up to 125 beats-per-minute (bpm). Conclusions: Synchronization of list-mode acquisition with external patient monitoring devices such as those employed in motion-tracking can reliably be achieved using a simple method that can be implemented using

  17. A method to synchronize signals from multiple patient monitoring devices through a single input channel for inclusion in list-mode acquisitions

    Energy Technology Data Exchange (ETDEWEB)

    O’Connor, J. Michael; Pretorius, P. Hendrik; Johnson, Karen; King, Michael A., E-mail: Michael.King@umassmed.edu [Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts 01655 (United States)

    2013-12-15

    Purpose: This technical note documents a method that the authors developed for combining a signal to synchronize a patient-monitoring device with a second physiological signal for inclusion into list-mode acquisition. Our specific application requires synchronizing an external patient motion-tracking system with a medical imaging system by multiplexing the tracking input with the ECG input. The authors believe that their methodology can be adapted for use in a variety of medical imaging modalities including single photon emission computed tomography (SPECT) and positron emission tomography (PET). Methods: The authors insert a unique pulse sequence into a single physiological input channel. This sequence is then recorded in the list-mode acquisition along with the R-wave pulse used for ECG gating. The specific form of our pulse sequence allows for recognition of the time point being synchronized even when portions of the pulse sequence are lost due to collisions with R-wave pulses. This was achieved by altering our software used in binning the list-mode data to recognize even a portion of our pulse sequence. Limitations on heart rates at which our pulse sequence could be reliably detected were investigated by simulating the mixing of the two signals as a function of heart rate and time point during the cardiac cycle at which our pulse sequence is mixed with the cardiac signal. Results: The authors have successfully achieved accurate temporal synchronization of our motion-tracking system with acquisition of SPECT projections used in 17 recent clinical research cases. In our simulation analysis the authors determined that synchronization to enable compensation for body and respiratory motion could be achieved for heart rates up to 125 beats-per-minute (bpm). Conclusions: Synchronization of list-mode acquisition with external patient monitoring devices such as those employed in motion-tracking can reliably be achieved using a simple method that can be implemented using

  18. Multiple double cross-section transmission electron microscope sample preparation of specific sub-10 nm diameter Si nanowire devices.

    Science.gov (United States)

    Gignac, Lynne M; Mittal, Surbhi; Bangsaruntip, Sarunya; Cohen, Guy M; Sleight, Jeffrey W

    2011-12-01

    The ability to prepare multiple cross-section transmission electron microscope (XTEM) samples from one XTEM sample of specific sub-10 nm features was demonstrated. Sub-10 nm diameter Si nanowire (NW) devices were initially cross-sectioned using a dual-beam focused ion beam system in a direction running parallel to the device channel. From this XTEM sample, both low- and high-resolution transmission electron microscope (TEM) images were obtained from six separate, specific site Si NW devices. The XTEM sample was then re-sectioned in four separate locations in a direction perpendicular to the device channel: 90° from the original XTEM sample direction. Three of the four XTEM samples were successfully sectioned in the gate region of the device. From these three samples, low- and high-resolution TEM images of the Si NW were taken and measurements of the NW diameters were obtained. This technique demonstrated the ability to obtain high-resolution TEM images in directions 90° from one another of multiple, specific sub-10 nm features that were spaced 1.1 μm apart.

  19. The MAST data acquisition upgrade

    International Nuclear Information System (INIS)

    McArdle, G.J.; Shibaev, Sergei; Storrs, John; Thomas-Davies, Nigel; Stephen, Robert

    2010-01-01

    A programme has begun on MAST to replace its ageing CAMAC and VME based data acquisition systems with new modern hardware which, together with several improvements in the supporting infrastructure, will provide support for faster data acquisition rates, longer-pulse operation, faster data access and higher reliability. The main principle of the upgrade was to use commercial off-the-shelf (COTS) hardware and well-established standards wherever possible. CompactPCI or PXI was chosen as the digitiser form factor to replace CAMAC/VME, and Ethernet would be used as the means to access all devices. The modular architecture of the MAST data acquisition software framework has helped to minimise the integration effort required to phase in new subsystems and/or new technologies whilst continuing to use the old hardware in other systems. The software framework was updated to allow more versatile use of the network-attached data acquisition devices. The new data acquisition devices had multiple connector types, which created difficulties with the cable interfacing. To resolve this and provide support for easy substitution, a standard connector interface was chosen, based on the most common connector type and pin-out already in use, and several cable assemblies were produced to connect the proprietary interface of the digitiser to the standard interface block. The in-house IDA-3 data storage format is unable to accommodate the larger file sizes and is increasingly difficult to maintain, so it is to be gradually phased out. The NetCDF-4/HDF5 data standard is being adopted as its replacement, thus reducing in-house maintenance whilst providing a data format that is more accessible to the Fusion community. Several other infrastructure upgrades were necessitated by the anticipated increase in data traffic and volume including the Central Timing System, the MAST Ethernet infrastructure and servers for front-end data processing, data storage and data access management. These

  20. Liquid oxygen liquid acquisition device bubble point tests with high pressure lox at elevated temperatures

    Science.gov (United States)

    Jurns, J. M.; Hartwig, J. W.

    2012-04-01

    When transferring propellant in space, it is most efficient to transfer single phase liquid from a propellant tank to an engine. In earth's gravity field or under acceleration, propellant transfer is fairly simple. However, in low gravity, withdrawing single-phase fluid becomes a challenge. A variety of propellant management devices (PMDs) are used to ensure single-phase flow. One type of PMD, a liquid acquisition device (LAD) takes advantage of capillary flow and surface tension to acquire liquid. The present work reports on testing with liquid oxygen (LOX) at elevated pressures (and thus temperatures) (maximum pressure 1724 kPa and maximum temperature 122 K) as part of NASA's continuing cryogenic LAD development program. These tests evaluate LAD performance for LOX stored in higher pressure vessels that may be used in propellant systems using pressure fed engines. Test data shows a significant drop in LAD bubble point values at higher liquid temperatures, consistent with lower liquid surface tension at those temperatures. Test data also indicates that there are no first order effects of helium solubility in LOX on LAD bubble point prediction. Test results here extend the range of data for LOX fluid conditions, and provide insight into factors affecting predicting LAD bubble point pressures.

  1. Novel Electrosorption-Enhanced Solid-Phase Microextraction Device for Ultrafast In Vivo Sampling of Ionized Pharmaceuticals in Fish.

    Science.gov (United States)

    Qiu, Junlang; Wang, Fuxin; Zhang, Tianlang; Chen, Le; Liu, Yuan; Zhu, Fang; Ouyang, Gangfeng

    2018-01-02

    Decreasing the tedious sample preparation duration is one of the most important concerns for the environmental analytical chemistry especially for in vivo experiments. However, due to the slow mass diffusion paths for most of the conventional methods, ultrafast in vivo sampling remains challenging. Herein, for the first time, we report an ultrafast in vivo solid-phase microextraction (SPME) device based on electrosorption enhancement and a novel custom-made CNT@PPY@pNE fiber for in vivo sampling of ionized acidic pharmaceuticals in fish. This sampling device exhibited an excellent robustness, reproducibility, matrix effect-resistant capacity, and quantitative ability. Importantly, the extraction kinetics of the targeted ionized pharmaceuticals were significantly accelerated using the device, which significantly improved the sensitivity of the SPME in vivo sampling method (limits of detection ranged from 0.12 ng·g -1 to 0.25 ng·g -1 ) and shorten the sampling time (only 1 min). The proposed approach was successfully applied to monitor the concentrations of ionized pharmaceuticals in living fish, which demonstrated that the device and fiber were suitable for ultrafast in vivo sampling and continuous monitoring. In addition, the bioconcentration factor (BCF) values of the pharmaceuticals were derived in tilapia (Oreochromis mossambicus) for the first time, based on the data of ultrafast in vivo sampling. Therefore, we developed and validated an effective and ultrafast SPME sampling device for in vivo sampling of ionized analytes in living organisms and this state-of-the-art method provides an alternative technique for future in vivo studies.

  2. Development of a large-solid-angle and multi-device detection system for elemental analysis

    International Nuclear Information System (INIS)

    Satoh, T.; Ishii, K.; Kamiya, T.; Sakai, T.; Oikawa, M.; Arakawa, K.; Matsuyama, S.; Yamazaki, H.

    2003-01-01

    A new detection apparatus for both low energy X-rays like 1 keV and back scattered protons of MeV energy was developed. The detection apparatus consists of a large-solid-angle multi-device Si detector and a data acquisition system. The detector has 45 detection devices which are arranged in the shape of a pentagonal pyramid and fully cover a sample. A micro-beam irradiates the sample through the center of the pentagonal pyramid and X-rays emitted from the sample are detected in a solid angle of about 1.0 sr. This novel detection setup has about five times higher sensitivity than a conventional micro-PIXE camera. In addition, not only X-rays but back scattered protons can be detected, since the counting rate of back scattered protons per detection device is small despite lack of a passive absorber

  3. Multi-channel data acquisition system with absolute time synchronization

    Energy Technology Data Exchange (ETDEWEB)

    Włodarczyk, Przemysław, E-mail: pan.wlodarczyk@uj.edu.pl [Department of Electronics, AGH University of Science and Technology, Mickiewicza 30, 30-059 Kraków (Poland); Institute of Physics, Jagiellonian University, Reymonta 4, 30-059 Kraków (Poland); Pustelny, Szymon, E-mail: pustelny@uj.edu.pl [Institute of Physics, Jagiellonian University, Reymonta 4, 30-059 Kraków (Poland); Budker, Dmitry [Department of Physics, University of California at Berkeley, Berkeley, California 94720-7300 (United States); Lipiński, Marcin [Department of Electronics, AGH University of Science and Technology, Mickiewicza 30, 30-059 Kraków (Poland)

    2014-11-01

    We present a low-cost, stand-alone global-time-synchronized data acquisition system. Our prototype allows recording up to four analog signals with a 16-bit resolution in variable ranges and a maximum sampling rate of 1000 S/s. The system simultaneously acquires readouts of external sensors e.g. magnetometer or thermometer. A complete data set, including a header containing timestamp, is stored on a Secure Digital (SD) card or transmitted to a computer using Universal Serial Bus (USB). The estimated time accuracy of the data acquisition is better than ±200 ns. The device is intended for use in a global network of optical magnetometers (the Global Network of Optical Magnetometers for Exotic physics – GNOME), which aims to search for signals heralding physics beyond the Standard Model, that can be generated by ordinary spin coupling to exotic particles or anomalous spin interactions.

  4. Data Acquisition for Modular Biometric Monitoring System

    Science.gov (United States)

    Chmiel, Alan J. (Inventor); Humphreys, Bradley T. (Inventor); Grodsinsky, Carlos M. (Inventor)

    2014-01-01

    A modular system for acquiring biometric data includes a plurality of data acquisition modules configured to sample biometric data from at least one respective input channel at a data acquisition rate. A representation of the sampled biometric data is stored in memory of each of the plurality of data acquisition modules. A central control system is in communication with each of the plurality of data acquisition modules through a bus. The central control system is configured to collect data asynchronously, via the bus, from the memory of the plurality of data acquisition modules according to a relative fullness of the memory of the plurality of data acquisition modules.

  5. Radiation-hardened fast acquisition/weak signal tracking system and method

    Science.gov (United States)

    Winternitz, Luke (Inventor); Boegner, Gregory J. (Inventor); Sirotzky, Steve (Inventor)

    2009-01-01

    A global positioning system (GPS) receiver and method of acquiring and tracking GPS signals comprises an antenna adapted to receive GPS signals; an analog radio frequency device operatively connected to the antenna and adapted to convert the GPS signals from an analog format to a digital format; a plurality of GPS signal tracking correlators operatively connected to the analog RF device; a GPS signal acquisition component operatively connected to the analog RF device and the plurality of GPS signal tracking correlators, wherein the GPS signal acquisition component is adapted to calculate a maximum vector on a databit correlation grid; and a microprocessor operatively connected to the plurality of GPS signal tracking correlators and the GPS signal acquisition component, wherein the microprocessor is adapted to compare the maximum vector with a predetermined correlation threshold to allow the GPS signal to be fully acquired and tracked.

  6. An original approach to data acquisition: CHADAC

    International Nuclear Information System (INIS)

    Huppert, M.; Nayman, P.; Rivoal, M.

    1981-01-01

    Many labs try to boost existing data acquisition systems by inserting high performance intelligent devices in the important nodes of the system's structure. This strategy finds its limits in the system's architecture. The CHADAC project proposes a simple and efficient solution to this problem, using a multiprocessor modular architecture. CHADAC main features are: a) Parallel acquisition of data: CHADAC is fast; it dedicates one processor per branch; each processor can read and store one 16 bit word in 800 ns. b) Original structure: each processor can work in its own private memory, in its own shared memory (double access) and in the shared memory of any other processor (this feature being particulary useful to avoid wasteful data transfers). Simple and fast communications between processors are also provided by local DMA'S. c) Flexibility: each processor is autonomous and may be used as an independent acquisition system for a branch, by connecting local peripherals to it. Adjunction of fast trigger logic is possible. By its architecture and performances, CHADAC is designed to provide a good support for local intelligent devices and transfer operators developped elsewhere, providing a way to implement systems well fitted to various types of data acquisition. (orig.)

  7. A tomograph VMEbus parallel processing data acquisition system

    International Nuclear Information System (INIS)

    Atkins, M.S.; Wilkinson, N.A.; Rogers, J.G.

    1988-11-01

    This paper describes a VME based data acquisition system suitable for the development of Positron Volume Imaging tomographs which use 3-D data for improved image resolution over slice-oriented tomographs. The data acquisition must be flexible enough to accommodate several 3-D reconstruction algorithms; hence, a software-based system is most suitable. Furthermore, because of the increased dimensions and resolution of volume imaging tomographs, the raw data event rate is greater than that of slice-oriented machines. These dual requirements are met by our data acquisition systems. Flexibility is achieved through an array of processors connected over a VMEbus, operating asynchronously and in parallel. High raw data throughput is achieved using a dedicated high speed data transfer device available for the VMEbus. The device can attain a raw data rate of 2.5 million coincidence events per second for raw events per second for raw events which are 64 bits wide. Real-time data acquisition and pre-processing requirements can be met by about forty 20 MHz Motorola 68020/68881 processors

  8. An automatic device for sample insertion and extraction to/from reactor irradiation facilities

    International Nuclear Information System (INIS)

    Alloni, L.; Venturelli, A.; Meloni, S.

    1990-01-01

    At the previous European Triga Users Conference in Vienna,a paper was given describing a new handling tool for irradiated samples at the L.E.N.A plant. This tool was the first part of an automatic device for the management of samples to be irradiated in the TRIGA MARK ii reactor and successively extracted and stored. So far sample insertion and extraction to/from irradiation facilities available on reactor top (central thimble,rotatory specimen rack and channel f),has been carried out manually by reactor and health-physics operators using the ''traditional'' fishing pole provided by General Atomic, thus exposing reactor personnel to ''unjustified'' radiation doses. The present paper describes the design and the operation of a new device, a ''robot''type machine,which, remotely operated, takes care of sample insertion into the different irradiation facilities,sample extraction after irradiation and connection to the storage pits already described. The extraction of irradiated sample does not require the presence of reactor personnel on the reactor top and,therefore,radiation doses are strongly reduced. All work from design to construction has been carried out by the personnel of the electronic group of the L.E.N.A plant. (orig.)

  9. Control and acquisition for MAST Thomson scattering diagnostics

    International Nuclear Information System (INIS)

    Shibaev, S.; Naylor, G.; Scannell, R.; McArdle, G.; O'Gorman, T.; Walsh, M.J.

    2010-01-01

    The MAST (mega-amp spherical tokamak) Thomson scattering (TS) diagnostics have been radically upgraded and expanded. Eight 30 Hz 1.6 J Nd:YAG lasers have been combined to produce a sampling rate of 240 Hz. The scattered signals are acquired by two spectrometer systems: core and edge. The core system has been built anew: collection optics, polychromators, digitizers, and control computers. It allows measurement of electron temperature and density at 130 spatial points with ∼10 mm resolution across the plasma. The Nd:YAG scattered light signals are registered in 650 channels as polychromator outputs; each channel is registered on two ADCs: at 1 GHz rate in a short interval around each laser pulse and at 100 kHz for background data. The fast ADCs are combined in 26 data acquisition units. Each unit is assembled in a 6 U PXI chassis with embedded controller and six 4-channel 1 GHz ADC cards. Some chassis contain a 96-channel slow ADC card with Ethernet control. The Ruby TS has been rebuilt with a new spectrometer and CCD camera to provide higher spatial resolution - 512 points; the laser has been modified to add double pulse capability. A new control and acquisition system has been developed; it has modular design allowing flexibility and seamless expansion. The system supports event-triggered and real-time operation (will be added in a later stage). A smart trigger device has been developed for TS timing and synchronisation. It provides complex pulse sequences for laser firing with resynchronisation on a number of digital and analogue inputs including plasma events. This device also triggers TS acquisition. The system is integrated by a TS master process running on the dedicated computer; it is represented as a standard MAST data acquisition unit. The Ruby TS is also implemented as a standard MAST unit linked with the Nd:YAG TS by MAST system services.

  10. Device for the analysis of feedwater and condensation samples from power plants

    International Nuclear Information System (INIS)

    Mostofin, A.A.; Sorokina, N.S.

    1978-01-01

    An improved version of a device for automatic measurement of the salt and NH 3 contents of feedwater and condensate samples from nuclear power plants is described. Only one sample is required for determining both values. The invention proposes on the one hand to change the dimensions of a throttle opening and on the other to install a second measuring instrument (conductivity measuring instrument). (UWI) [de

  11. Sampling technologies and air pollution control devices for gaseous and particulate arsenic: a review

    International Nuclear Information System (INIS)

    Helsen, Lieve

    2005-01-01

    Direct measurement of arsenic release requires a good sampling and analysis procedure in order to capture and detect the total amount of metals emitted. The literature is extensively reviewed in order to evaluate the efficiency of full field-scale and laboratory scale techniques for capturing particulate and gaseous emissions of arsenic from the thermo-chemical treatment of different sources of arsenic. Furthermore, trace arsenic concentrations in ambient air, national standard sampling methods and arsenic analysis methods are considered. Besides sampling techniques, the use of sorbents is also reviewed with respect to both approaches (1) to prevent the metals from exiting with the flue gas and (2) to react or combine with the metals in order to be collected in air pollution control systems. The most important conclusion is that submicron arsenic fumes are difficult to control in conventional air pollution control devices. Complete capture of the arsenic species requires a combination of particle control and vapour control devices. - Submicron arsenic fumes are difficult to control in conventional air pollution control devices

  12. Development of a data acquisition unit intended for pulsed plasma measurements

    International Nuclear Information System (INIS)

    Moulin, B.

    1976-12-01

    A system suitable for the acquisition of the signals from measuring devices implanted in Petula and Wega is described. The technical specifications of the data acquisition system are discussed together with the results obtained [fr

  13. A tomograph VMEbus parallel processing data acquisition system

    International Nuclear Information System (INIS)

    Wilkinson, N.A.; Rogers, J.G.; Atkins, M.S.

    1989-01-01

    This paper describes a VME based data acquisition system suitable for the development of Positron Volume Imaging tomographs which use 3-D data for improved image resolution over slice-oriented tomographs. the data acquisition must be flexible enough to accommodate several 3-D reconstruction algorithms; hence, a software-based system is most suitable. Furthermore, because of the increased dimensions and resolution of volume imaging tomographs, the raw data event rate is greater than that of slice-oriented machines. These dual requirements are met by our data acquisition system. Flexibility is achieved through an array of processors connected over a VMEbus, operating asynchronously and in parallel. High raw data throughput is achieved using a dedicated high speed data transfer device available for the VMEbus. The device can attain a raw data rate of 2.5 million coincidence events per second for raw events which are 64 bits wide

  14. TFTR diagnostic control and data acquisition system

    International Nuclear Information System (INIS)

    Sauthoff, N.R.; Daniels, R.E.; PPL Computer Division

    1985-01-01

    General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man--machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ''groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development

  15. A Simple Device for Lens-to-Sample Distance Adjustment in Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Cortez, Juliana; Farias Filho, Benedito B; Fontes, Laiane M; Pasquini, Celio; Raimundo, Ivo M; Pimentel, Maria Fernanda; de Souza Lins Borba, Flávia

    2017-04-01

    A simple device based on two commercial laser pointers is described to assist in the analysis of samples that present uneven surfaces and/or irregular shapes using laser-induced breakdown spectroscopy (LIBS). The device allows for easy positioning of the sample surface at a reproducible distance from the focusing lens that conveys the laser pulse to generate the micro-plasma in a LIBS system, with reproducibility better than ±0.2 mm. In this way, fluctuations in the fluence (J cm -2 ) are minimized and the LIBS analytical signals can be obtained with a better precision even when samples with irregular surfaces are probed.

  16. Short communication: Influence of the sampling device on somatic cell count variation in cow milk samples (by official recording)

    International Nuclear Information System (INIS)

    Fouz, R.; Vilar, M.J.; Yus, E.; Sanjuán, M.L.; Diéguez, F.J.

    2016-01-01

    The objective of this study was to investigate the variability in cow´s milk somatic cell counts (SCC) depending on the type of milk meter used by dairy farms for official milk recording. The study was performed in 2011 and 2012 in the major cattle area of Spain. In total, 137,846 lactations of Holstein-Friesian cows were analysed at 1,912 farms. A generalised least squares regression model was used for data analysis. The model showed that the milk meter had a substantial effect on the SCC for individual milk samples obtained for official milk recording. The results suggested an overestimation of the SCC in milk samples from farms that had electronic devices in comparison with farms that used portable devices and underestimation when volumetric meters are used. A weak positive correlation was observed between the SCC and the percentage of fat in individual milk samples. The results underline the importance of considering this variable when using SCC data from milk recording in the dairy herd improvement program or in quality milk programs. (Author)

  17. Short communication: Influence of the sampling device on somatic cell count variation in cow milk samples (by official recording)

    Energy Technology Data Exchange (ETDEWEB)

    Fouz, R.; Vilar, M.J.; Yus, E.; Sanjuán, M.L.; Diéguez, F.J.

    2016-11-01

    The objective of this study was to investigate the variability in cow´s milk somatic cell counts (SCC) depending on the type of milk meter used by dairy farms for official milk recording. The study was performed in 2011 and 2012 in the major cattle area of Spain. In total, 137,846 lactations of Holstein-Friesian cows were analysed at 1,912 farms. A generalised least squares regression model was used for data analysis. The model showed that the milk meter had a substantial effect on the SCC for individual milk samples obtained for official milk recording. The results suggested an overestimation of the SCC in milk samples from farms that had electronic devices in comparison with farms that used portable devices and underestimation when volumetric meters are used. A weak positive correlation was observed between the SCC and the percentage of fat in individual milk samples. The results underline the importance of considering this variable when using SCC data from milk recording in the dairy herd improvement program or in quality milk programs. (Author)

  18. A data acquisition system based on PC-CAMAC BUS

    International Nuclear Information System (INIS)

    Xie Xiangyang; Jiang Haiyan; Luo Jiarong; Ji Zhenshan

    2000-08-01

    The author introduces a Data Acquisition System applied to HT-7 (a superconduction Tokamak device). The system is based on the CAMAC standard and the personal computer. The software has been written in C language. The system performs the following tasks: setup parameters of modules, data acquisition, disk data storage and their display

  19. Can augmented force feedback facilitate virtual target acquisition tasks?

    NARCIS (Netherlands)

    Houtsma, A.J.M.; Keuning - van Oirschot, H.; Westwood, J.D.; Haluck, R.S.

    2006-01-01

    This study investigates facilitation of a manual target acquisition task by the application of appropriate force feedback through the control device (e.g., mouse, joystick, trackball). Typical manual movements with these devices were measured, and models of such movements were used to predict an

  20. [Electronic Device for Retinal and Iris Imaging].

    Science.gov (United States)

    Drahanský, M; Kolář, R; Mňuk, T

    This paper describes design and construction of a new device for automatic capturing of eye retina and iris. This device has two possible ways of utilization - either for biometric purposes (persons recognition on the base of their eye characteristics) or for medical purposes as supporting diagnostic device. eye retina, eye iris, device, acquisition, image.

  1. Dynamic autofocus for continuous-scanning time-delay-and-integration image acquisition in automated microscopy.

    Science.gov (United States)

    Bravo-Zanoguera, Miguel E; Laris, Casey A; Nguyen, Lam K; Oliva, Mike; Price, Jeffrey H

    2007-01-01

    Efficient image cytometry of a conventional microscope slide means rapid acquisition and analysis of 20 gigapixels of image data (at 0.3-microm sampling). The voluminous data motivate increased acquisition speed to enable many biomedical applications. Continuous-motion time-delay-and-integrate (TDI) scanning has the potential to speed image acquisition while retaining sensitivity, but the challenge of implementing high-resolution autofocus operating simultaneously with acquisition has limited its adoption. We develop a dynamic autofocus system for this need using: 1. a "volume camera," consisting of nine fiber optic imaging conduits to charge-coupled device (CCD) sensors, that acquires images in parallel from different focal planes, 2. an array of mixed analog-digital processing circuits that measure the high spatial frequencies of the multiple image streams to create focus indices, and 3. a software system that reads and analyzes the focus data streams and calculates best focus for closed feedback loop control. Our system updates autofocus at 56 Hz (or once every 21 microm of stage travel) to collect sharply focused images sampled at 0.3x0.3 microm(2)/pixel at a stage speed of 2.3 mms. The system, tested by focusing in phase contrast and imaging long fluorescence strips, achieves high-performance closed-loop image-content-based autofocus in continuous scanning for the first time.

  2. A Targeted Infection Prevention Intervention in Nursing Home Residents With Indwelling Devices

    Science.gov (United States)

    Mody, Lona; Krein, Sarah L.; Saint, Sanjay K.; Min, Lillian C.; Montoya, Ana; Lansing, Bonnie; McNamara, Sara E.; Symons, Kathleen; Fisch, Jay; Koo, Evonne; Rye, Ruth Anne; Galecki, Andrzej; Kabeto, Mohammed U.; Fitzgerald, James T.; Olmsted, Russell N.; Kauffman, Carol A.; Bradley, Suzanne F.

    2015-01-01

    IMPORTANCE Indwelling devices (eg, urinary catheters and feeding tubes) are often used in nursing homes (NHs). Inadequate care of residents with these devices contributes to high rates of multidrug-resistant organisms (MDROs) and device-related infections in NHs. OBJECTIVE To test whether a multimodal targeted infection program (TIP) reduces the prevalence of MDROs and incident device-related infections. DESIGN, SETTING, AND PARTICIPANTS Randomized clinical trial at 12 community-based NHs from May 2010 to April 2013. Participants were high-risk NH residents with urinary catheters, feeding tubes, or both. INTERVENTIONS Multimodal, including preemptive barrier precautions, active surveillance for MDROs and infections, and NH staff education. MAIN OUTCOMES AND MEASURES The primary outcome was the prevalence density rate of MDROs, defined as the total number of MDROs isolated per visit averaged over the duration of a resident's participation. Secondary outcomes included new MDRO acquisitions and new clinically defined device-associated infections. Data were analyzed using a mixed-effects multilevel Poisson regression model (primary outcome) and a Cox proportional hazards model (secondary outcome), adjusting for facility-level clustering and resident-level variables. RESULTS In total, 418 NH residents with indwelling devices were enrolled, with 34 174 device-days and 6557 anatomic sites sampled. Intervention NHs had a decrease in the overall MDRO prevalence density (rate ratio, 0.77; 95% CI, 0.62–0.94). The rate of new methicillin-resistant Staphylococcus aureus acquisitions was lower in the intervention group than in the control group (rate ratio, 0.78; 95% CI, 0.64–0.96). Hazard ratios for the first and all (including recurrent) clinically defined catheter-associated urinary tract infections were 0.54 (95% CI, 0.30–0.97) and 0.69 (95% CI, 0.49–0.99), respectively, in the intervention group and the control group. There were no reductions in new vancomycin

  3. Control and data acquisition system for versatile experiment spherical torus at SNU

    Energy Technology Data Exchange (ETDEWEB)

    An, YoungHwa [Department of Nuclear Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of); Chung, Kyoung-Jae, E-mail: jkjlsh1@snu.ac.kr [Department of Nuclear Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of); Na, DongHyeon; Hwang, Y.S. [Department of Nuclear Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of)

    2013-10-15

    A control and data acquisition system for VEST (Versatile Experiment Spherical Torus) at Seoul National University (SNU) has been developed to enable remote operation from a central control room. The control and data acquisition system consists of three subsystems; a main control and data acquisition system that triggers each device at the preprogrammed timing and collects various diagnostic signals during discharges, a monitoring system that watches and logs the device status continuously, and a data storage and distribution system that stores collected data and provides data access layer via Ethernet. The system is designed to be cost-effective, extensible and easy to develop by using well-established standard technologies and solutions. Combining broad accessibility with modern information technology, alarm signal can be sent immediately to the registered cell phones when the abnormal status of devices is found, and the web data distribution system enables data access from almost everywhere using smart phones or tablet computers. Since December 2011, VEST is operational and the control and data acquisition system has been successfully used for remote operation of VEST.

  4. Control and data acquisition system for versatile experiment spherical torus at SNU

    International Nuclear Information System (INIS)

    An, YoungHwa; Chung, Kyoung-Jae; Na, DongHyeon; Hwang, Y.S.

    2013-01-01

    A control and data acquisition system for VEST (Versatile Experiment Spherical Torus) at Seoul National University (SNU) has been developed to enable remote operation from a central control room. The control and data acquisition system consists of three subsystems; a main control and data acquisition system that triggers each device at the preprogrammed timing and collects various diagnostic signals during discharges, a monitoring system that watches and logs the device status continuously, and a data storage and distribution system that stores collected data and provides data access layer via Ethernet. The system is designed to be cost-effective, extensible and easy to develop by using well-established standard technologies and solutions. Combining broad accessibility with modern information technology, alarm signal can be sent immediately to the registered cell phones when the abnormal status of devices is found, and the web data distribution system enables data access from almost everywhere using smart phones or tablet computers. Since December 2011, VEST is operational and the control and data acquisition system has been successfully used for remote operation of VEST

  5. A system design of data acquisition and processing for side-scatter lidar

    Science.gov (United States)

    Zhang, ZhanYe; Xie, ChenBo; Wang, ZhenZhu; Kuang, ZhiQiang; Deng, Qian; Tao, ZongMing; Liu, Dong; Wang, Yingjian

    2018-03-01

    A system for collecting data of Side-Scatter lidar based on Charge Coupled Device (CCD),is designed and implemented. The system of data acquisition is based on Microsoft. Net structure and the language of C# is used to call dynamic link library (DLL) of CCD for realization of the real-time data acquisition and processing. The software stores data as txt file for post data acquisition and analysis. The system has ability to operate CCD device in all-day, automatic, continuous and high frequency data acquisition and processing conditions, which will catch 24-hour information of the atmospheric scatter's light intensity and retrieve the spatial and temporal properties of aerosol particles. The experimental result shows that the system is convenient to observe the aerosol optical characteristics near surface.

  6. A real-time data acquisition and processing system for the analytical laboratory automation of a HTR spent fuel reprocessing facility

    International Nuclear Information System (INIS)

    Watzlawik, K.H.

    1979-12-01

    A real-time data acquisition and processing system for the analytical laboratory of an experimental HTR spent fuel reprocessing facility is presented. The on-line open-loop system combines in-line and off-line analytical measurement procedures including data acquisition and evaluation as well as analytical laboratory organisation under the control of a computer-supported laboratory automation system. In-line measurements are performed for density, volume and temperature in process tanks and registration of samples for off-line measurements. Off-line computer-coupled experiments are potentiometric titration, gas chromatography and X-ray fluorescence analysis. Organisational sections like sample registration, magazining, distribution and identification, multiple data assignment and especially calibrations of analytical devices are performed by the data processing system. (orig.) [de

  7. MAST data acquisition system

    International Nuclear Information System (INIS)

    Shibaev, S.; Counsell, G.; Cunningham, G.; Manhood, S.J.; Thomas-Davies, N.; Waterhouse, J.

    2006-01-01

    The data acquisition system of the Mega-Amp Spherical Tokamak (MAST) presently collects up to 400 MB of data in about 3000 data items per shot, and subsequent fast growth is expected. Since the start of MAST operations (in 1999) the system has changed dramatically. Though we continue to use legacy CAMAC hardware, newer VME, PCI, and PXI based sub-systems collect most of the data now. All legacy software has been redesigned and new software has been developed. Last year a major system improvement was made-replacement of the message distribution system. The new message system provides easy connection of any sub-system independently of its platform and serves as a framework for many new applications. A new data acquisition controller provides full control of common sub-systems, central error logging, and data acquisition alarms for the MAST plant. A number of new sub-systems using Linux and Windows OSs on VME, PCI, and PXI platforms have been developed. A new PXI unit has been designed as a base sub-system accommodating any type of data acquisition and control devices. Several web applications for the real-time MAST monitoring and data presentation have been developed

  8. Paper-Based Analytical Device for Zinc Ion Quantification in Water Samples with Power-Free Analyte Concentration

    Directory of Open Access Journals (Sweden)

    Hiroko Kudo

    2017-04-01

    Full Text Available Insufficient sensitivity is a general issue of colorimetric paper-based analytical devices (PADs for trace analyte detection, such as metal ions, in environmental water. This paper demonstrates the colorimetric detection of zinc ions (Zn2+ on a paper-based analytical device with an integrated analyte concentration system. Concentration of Zn2+ ions from an enlarged sample volume (1 mL has been achieved with the aid of a colorimetric Zn2+ indicator (Zincon electrostatically immobilized onto a filter paper substrate in combination with highly water-absorbent materials. Analyte concentration as well as sample pretreatment, including pH adjustment and interferent masking, has been elaborated. The resulting device enables colorimetric quantification of Zn2+ in environmental water samples (tap water, river water from a single sample application. The achieved detection limit of 0.53 μM is a significant improvement over that of a commercial colorimetric Zn2+ test paper (9.7 μM, demonstrating the efficiency of the developed analyte concentration system not requiring any equipment.

  9. Design and implementation of a wireless (Bluetooth) four channel bio-instrumentation amplifier and digital data acquisition device with user-selectable gain, frequency, and driven reference.

    Science.gov (United States)

    Cosmanescu, Alin; Miller, Benjamin; Magno, Terence; Ahmed, Assad; Kremenic, Ian

    2006-01-01

    A portable, multi-purpose Bio-instrumentation Amplifier and Data AcQuisition device (BADAQ) capable of measuring and transmitting EMG and EKG signals wirelessly via Bluetooth is designed and implemented. Common topologies for instrumentation amplifiers and filters are used and realized with commercially available, low-voltage, high precision operational amplifiers. An 8-bit PIC microcontroller performs 10-bit analog-to-digital conversion of the amplified and filtered signals and controls a Bluetooth transceiver capable of wirelessly transmitting the data to any Bluetooth enabled device. Electrical isolation between patient/subject, circuitry, and ancillary equipment is achieved by optocoupling components. The design focuses on simplicity, portability, and affordability.

  10. Acquisition of ICU data: concepts and demands.

    Science.gov (United States)

    Imhoff, M

    1992-12-01

    As the issue of data overload is a problem in critical care today, it is of utmost importance to improve acquisition, storage, integration, and presentation of medical data, which appears only feasible with the help of bedside computers. The data originates from four major sources: (1) the bedside medical devices, (2) the local area network (LAN) of the ICU, (3) the hospital information system (HIS) and (4) manual input. All sources differ markedly in quality and quantity of data and in the demands of the interfaces between source of data and patient database. The demands for data acquisition from bedside medical devices, ICU-LAN and HIS concentrate on technical problems, such as computational power, storage capacity, real-time processing, interfacing with different devices and networks and the unmistakable assignment of data to the individual patient. The main problem of manual data acquisition is the definition and configuration of the user interface that must allow the inexperienced user to interact with the computer intuitively. Emphasis must be put on the construction of a pleasant, logical and easy-to-handle graphical user interface (GUI). Short response times will require high graphical processing capacity. Moreover, high computational resources are necessary in the future for additional interfacing devices such as speech recognition and 3D-GUI. Therefore, in an ICU environment the demands for computational power are enormous. These problems are complicated by the urgent need for friendly and easy-to-handle user interfaces. Both facts place ICU bedside computing at the vanguard of present and future workstation development leaving no room for solutions based on traditional concepts of personal computers.(ABSTRACT TRUNCATED AT 250 WORDS)

  11. A Low-Cost Modular Platform for Heterogeneous Data Acquisition with Accurate Interchannel Synchronization.

    Science.gov (United States)

    Blanco-Claraco, José Luis; López-Martínez, Javier; Torres-Moreno, José Luis; Giménez-Fernández, Antonio

    2015-10-27

    Most experimental fields of science and engineering require the use of data acquisition systems (DAQ), devices in charge of sampling and converting electrical signals into digital data and, typically, performing all of the required signal preconditioning. Since commercial DAQ systems are normally focused on specific types of sensors and actuators, systems engineers may need to employ mutually-incompatible hardware from different manufacturers in applications demanding heterogeneous inputs and outputs, such as small-signal analog inputs, differential quadrature rotatory encoders or variable current outputs. A common undesirable side effect of heterogeneous DAQ hardware is the lack of an accurate synchronization between samples captured by each device. To solve such a problem with low-cost hardware, we present a novel modular DAQ architecture comprising a base board and a set of interchangeable modules. Our main design goal is the ability to sample all sources at predictable, fixed sampling frequencies, with a reduced synchronization mismatch (vibration spectrum analyses from piezoelectric accelerometers and, as a novelty in these kinds of experiments, the spectrum of quadrature encoder signals. Part of the design and software will be publicly released online.

  12. CDC field mapping device - ''ROTOTRACK''

    International Nuclear Information System (INIS)

    Yamada, R.; Hawtree, J.; Kaczar, K.; Leverence, R.; McGuire, K.; Newman-Holmes, C.; Schmidt, E.E.; Shallenberger, J.

    1985-10-01

    A field mapping device for the magnet of the Collider Detector at Fermilab (CDF) was constructed. The device was used for extensive study of the CDF magnetic field distribution. The mechanical and electrical features of the device, as well as the data acquisition system and software, are described. The mechanical system was designed so that the errors on the position and angle of the probe were +-0.75 mm and +-1 mrad, respectively

  13. Use of passive sampling devices for monitoring and compliance checking of POP concentrations in water

    NARCIS (Netherlands)

    Lohmann, R.; Booij, K.; Smedes, F.; Vrana, B.

    2012-01-01

    The state of the art of passive water sampling of (nonpolar) organic contaminants is presented. Its suitability for regulatory monitoring is discussed, with an emphasis on the information yielded by passive sampling devices (PSDs), their relevance and associated uncertainties. Almost all persistent

  14. Control and data acquisition system for rotary compressor

    Directory of Open Access Journals (Sweden)

    Buczaj Marcin

    2017-01-01

    Full Text Available The rotary compressor (crimping machine is a machine designed for making hollow forgings. The rotary compressor is a prototype device designed and built at the Technical University of Lublin. The compressor is dedicated to perform laboratory tests related to the hollow forgings of various shapes using different materials. Since the rotary compressor is an experimental device, there is no control and acquisition data system available. The article presents the concept and the capabilities of the computer control and data acquisition system supporting rotary compressing process. The main task of software system is acquisition of force and kinetic parameters related to the analysed process of the rotary forging compression. The software allows the user to declare the course of the forming forgings. This system allows current recording and analysis of four physical values: feed rate (speed of working head movement, hydraulic oil pressure at inlet and outlet of hydraulic cylinder and the torque of engine. Application functions can be divided into three groups: the configuration of the pressing process, the acquisition and analysis of data from the pressing process and the recording and presentation of stored results. The article contains a detailed description about hardware and software implementation of mentioned functions.

  15. The transient electric field measurement system for EAST device

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Y., E-mail: wayong@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Ji, Z.S. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Zhu, C.M. [The Experiment & Verification Center of State Grid Electric Power Research Institute (The Automation Equipment EMC Lab. of State Grid Co.), Nanjing, Jiangsu (China); Zhang, Z.C.; Ma, T.F.; Xu, Z.H. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China)

    2016-11-15

    The electromagnetic environment around the Experimental Advanced Superconducting Tokamak (EAST) device is very complex during plasma discharge experiment. In order to fully monitor the changes of electric field around the EAST device during plasma discharge, a transient electric field measurement system based on PCI eXtensions for Instrumentation (PXI) platform has been designed. A digitizer is used for high-speed data acquisition of raw signals from electric field sensors, and a Field Programmable Gate Array (FPGA) module is used for realizing an on-the-fly fast Fourier transform (FFT) and inverse fast Fourier transform (IFFT) algorithm including a beforehand identified antenna factor (AF) to achieve finally a calibrated and filtered electric field measurement, then these signals can be displayed and easily analyzed. The raw signals from electric field sensors are transferred through optical fiber by optical isolation to reduce electromagnetic interference (EMI). The high speed data streaming technology is used for data storage. A prototype of this system has been realized to measure the transient electric field strength, with the real-time processing and continuous acquisition ability of one channel of 14-bit resolution and up to 50 MHz sampling rate, and 6 KHz FFT frequency resolution.

  16. Pore water sampling in acid sulfate soils: a new peeper method.

    Science.gov (United States)

    Johnston, Scott G; Burton, Edward D; Keene, Annabelle F; Bush, Richard T; Sullivan, Leigh A; Isaacson, Lloyd

    2009-01-01

    This study describes the design, deployment, and application of a modified equilibration dialysis device (peeper) optimized for sampling pore waters in acid sulfate soils (ASS). The modified design overcomes the limitations of traditional-style peepers, when sampling firm ASS materials over relatively large depth intervals. The new peeper device uses removable, individual cells of 25 mL volume housed in a 1.5 m long rigid, high-density polyethylene rod. The rigid housing structure allows the device to be inserted directly into relatively firm soils without requiring a supporting frame. The use of removable cells eliminates the need for a large glove-box after peeper retrieval, thus simplifying physical handling. Removable cells are easily maintained in an inert atmosphere during sample processing and the 25-mL sample volume is sufficient for undertaking multiple analyses. A field evaluation of equilibration times indicates that 32 to 38 d of deployment was necessary. Overall, the modified method is simple and effective and well suited to acquisition and processing of redox-sensitive pore water profiles>1 m deep in acid sulfate soil or any other firm wetland soils.

  17. VAPOR SAMPLING DEVICE FOR INTERFACE WITH MICROTOX ASSAY FOR SCREENING TOXIC INDUSTRIAL CHEMICALS

    Science.gov (United States)

    A time-integrated sampling system interfaced with a toxicity-based assay is reported for monitoring volatile toxic industrial chemicals (TICs). Semipermeable membrane devices (SPMDs) using dimethyl sulfoxide (DMSO) as the fill solvent accumulated each of 17 TICs from the vapor...

  18. Data acquisition for PLT

    International Nuclear Information System (INIS)

    Thompson, P.A.

    1975-01-01

    DA/PLT, the data acquisition system for the Princeton Large Torus (PLT) fusion research device, consists of a PDP-10 host computer, five satellite PDP-11s connected to the host by a special high-speed interface, miscellaneous other minicomputers and commercially supplied instruments, and much PPPL produced hardware. The software consists of the standard PDP-10 monitor with local modifications and the special systems and applications programs to customize the DA/PLT for the specific job of supporting data acquisition, analysis, display, and archiving, with concurrent off-line analysis, program development, and, in the background, general batch and timesharing. Some details of the over-all architecture are presented, along with a status report of the different PLT experiments being supported

  19. 14CO2 analysis of soil gas: Evaluation of sample size limits and sampling devices

    Science.gov (United States)

    Wotte, Anja; Wischhöfer, Philipp; Wacker, Lukas; Rethemeyer, Janet

    2017-12-01

    Radiocarbon (14C) analysis of CO2 respired from soils or sediments is a valuable tool to identify different carbon sources. The collection and processing of the CO2, however, is challenging and prone to contamination. We thus continuously improve our handling procedures and present a refined method for the collection of even small amounts of CO2 in molecular sieve cartridges (MSCs) for accelerator mass spectrometry 14C analysis. Using a modified vacuum rig and an improved desorption procedure, we were able to increase the CO2 recovery from the MSC (95%) as well as the sample throughput compared to our previous study. By processing series of different sample size, we show that our MSCs can be used for CO2 samples of as small as 50 μg C. The contamination by exogenous carbon determined in these laboratory tests, was less than 2.0 μg C from fossil and less than 3.0 μg C from modern sources. Additionally, we tested two sampling devices for the collection of CO2 samples released from soils or sediments, including a respiration chamber and a depth sampler, which are connected to the MSC. We obtained a very promising, low process blank for the entire CO2 sampling and purification procedure of ∼0.004 F14C (equal to 44,000 yrs BP) and ∼0.003 F14C (equal to 47,000 yrs BP). In contrast to previous studies, we observed no isotopic fractionation towards lighter δ13C values during the passive sampling with the depth samplers.

  20. 3D Data Acquisition Platform for Human Activity Understanding

    Science.gov (United States)

    2016-03-02

    SECURITY CLASSIFICATION OF: In this project, we incorporated motion capture devices, 3D vision sensors, and EMG sensors to cross validate...multimodality data acquisition, and address fundamental research problems of representation and invariant description of 3D data, human motion modeling and...applications of human activity analysis, and computational optimization of large-scale 3D data. The support for the acquisition of such research

  1. Acquisitions by EMNCs in Developed Markets

    DEFF Research Database (Denmark)

    Rabbiosi, Larissa; Elia, Stefano; Bertoni, Fabio

    2012-01-01

    Building on an organisational learning perspective, we argue that emerging market firms’ international experience and home-country characteristics are core sources of learning. Furthermore, we argue that these factors constitute important determinants of emerging market firms’ acquisition behaviour...... in developed countries (south-north acquisitions). We test our hypotheses on a sample of 808 south-north acquisitions. The acquisitions were undertaken in Europe, Japan and North America (Canada and the US) between 1999 and 2008 by firms from the emerging economies of Brazil, Russia, India and China....... As suggested by the internationalisation process model, our results show that emerging market firms undertake acquisitions in developed countries in an incremental fashion. Acquisition experience in developed markets increases the likelihood of exploitative expansion, while acquisition experience in developing...

  2. Device for the acquisition and visualization in real time of the velocity and direction of wind in a radiological post stage

    International Nuclear Information System (INIS)

    Ledo P, L.M.; Guibert G, R.; Dominguez L, O.; Alonso A, D.; Ramos V, E.O.

    2006-01-01

    The work shows the development, construction and post stage of a device dedicated to the acquisition and transmission in real time of the information on the behavior of the meteorological variables: velocity and wind direction. It is introduced for the first time in an observation position the automatic monitoring, in real time, using the tools that it offers the digitalisation of the information and the computation. The obtained data are registered in a PC, its are visualized appropriately and can be objects of later analysis. It was developed the application program Autoclima for such purpose. (Author)

  3. Fabrication and Characterization of a Microfluidic Device to Ultrapurify Blood Samples

    KAUST Repository

    Tallerico, Marco

    2015-05-04

    The improvement of blood cell sorting techniques in recent years have attracted the attention of many researchers due to the possible benefits that these methods can lead in biology, regenerative medicine, materials science and therapeutic area. In this work a cell sorting technique based on filtration is described. The separation occurs by means of a microfluidic device, suitably designed, manufactured and tested, that is connected to an external experimental set-up. The fabrication process can be divided in two parts: at first it is described the manufacturing process of a filtering membrane, with holes of specific size that allow the passage of only certain cell types. Following the microfluidic device is fabricated through the mechanical micromilling. The membrane and the microdevice are suitably bonded and tested by means of an external connection with syringe pumps that inject blood samples at specific flow rates. The device is designed to separate blood cells and tumor cells only by using differences in size and shape. In particular during the first experiments red blood cells and platelets are sorted from white blood cells; in the other experiments red blood cells and platelets are separated from white blood cells and tumor cells. The microdevice has proven to be very efficient, in fact a capture efficiency of 99% is achieved. For this reason it could be used in identification and isolation of circulating tumor cells, a very rare cancer cell type whose presence in the bloodstream could be symptom of future solid tumor formation. The various experiments have also demonstrated that tumor cells survive even after the separation treatment, and then the suffered stress during the sorting process does not harm the biological sample.

  4. Networked Attached Devices at SNS

    CERN Document Server

    Blokland, W

    2003-01-01

    The Spallation Neutron Source (SNS) diagnostic instruments at Oak Ridge National Laboratory are based on the Network Attached Device (NAD) concept. Each pickup or sensor has its own resources such as timing, data acquisition and processing. NADs are individually connected to the network, thus reducing the brittleness inherent in tightly coupled systems. This architecture allows an individual device to fail or to be serviced or removed without disrupting other devices. This paper describes our implementation of the nearly 400 NADs to be deployed. The hardware consists of rack-mounted PCs with standard motherboards and PCI data-acquisition boards. The software environment is based on LabVIEW and EPICS. LabVIEW supports the agile development demanded by modern diagnostic systems. EPICS is the control system standard for the entire SNS facility. To achieve high performance, LabVIEW and EPICS communicate through shared memory. SNS diagnostics are developed by a multi-laboratory partnership including ORNL, BNL, LAN...

  5. Design of remote laser-induced fluorescence system's acquisition circuit

    Science.gov (United States)

    Wang, Guoqing; Lou, Yue; Wang, Ran; Yan, Debao; Li, Xin; Zhao, Xin; Chen, Dong; Zhao, Qi

    2017-10-01

    Laser-induced fluorescence system(LIfS) has been found its significant application in identifying one kind of substance from another by its properties even it's thimbleful, and becomes useful in plenty of fields. Many superior works have reported LIfS' theoretical analysis , designs and uses. However, the usual LIPS is always constructed in labs to detect matter quite closely, for the system using low-power laser as excitation source and charge coupled device (CCD) as detector. Promoting the detectivity of LIfS is of much concern to spread its application. Here, we take a high-energy narrow-pulse laser instead of commonly used continuous wave laser to operate sample, thus we can get strong fluorescent. Besides, photomultiplier (PMT) with high sensitivity is adopted in our system to detect extremely weak fluorescence after a long flight time from the sample to the detector. Another advantage in our system, as the fluorescence collected into spectroscopy, multiple wavelengths of light can be converted to the corresponding electrical signals with the linear array multichannel PMT. Therefore, at the cost of high-powered incentive and high-sensitive detector, a remote LIFS is get. In order to run this system, it is of importance to turn light signal to digital signal which can be processed by computer. The pulse width of fluorescence is deeply associated with excitation laser, at the nanosecond(ns) level, which has a high demand for acquisition circuit. We design an acquisition circuit including, I/V conversion circuit, amplifying circuit and peak-holding circuit. The simulation of circuit shows that peak-holding circuit can be one effective approach to reducing difficulty of acquisition circuit.

  6. Specific Cognitive Antecedents of Structures and Functions Involved in Language Acquisition

    Science.gov (United States)

    Moerk, Ernst L.

    1973-01-01

    The antecedents of verbal behavior, together with the teaching skills of the adult linguistic community, probably constitute all the necessary bases for language acquisition. As they seemed to be sufficient for the explanation of all the known phenomena, an assumption of an innate linguistic language acquisition device was rejected as superfluous.…

  7. Industry Relatedness and Post-Acquisition Innovative Performance

    DEFF Research Database (Denmark)

    Cefis, Elena; Marsili, Orietta; Rigamonti, Damiana

    2015-01-01

    This paper examines how characteristics of acquiring and acquired firms influence the curvilinear (inverted U-shaped) relationship between relatedness and post-acquisition innovative performance. Using a relatedness index based on industry co-occurrence in a sample of 1,736 Dutch acquisitions, we...... find that acquirer's internal R&D and acquisition experience, and the small size of acquired firms, help to reach a balance between exploration of novelty and exploitation of synergies in unrelated acquisitions, and to achieve higher post-acquisition performance. However, while the acquirer's R......&D increases flexibility in the acquisition process in presence of deviations from the optimal level of relatedness, acquisition experience may enhance rigidities....

  8. WE-G-204-08: Optimized Digital Radiographic Technique for Lost Surgical Devices/Needle Identification

    International Nuclear Information System (INIS)

    Gorman, A; Seabrook, G; Brakken, A; Dubois, M; Marn, C; Wilson, C; Jacobson, D; Liu, Y

    2015-01-01

    Purpose: Small surgical devices and needles are used in many surgical procedures. Conventionally, an x-ray film is taken to identify missing devices/needles if post procedure count is incorrect. There is no data to indicate smallest surgical devices/needles that can be identified with digital radiography (DR), and its optimized acquisition technique. Methods: In this study, the DR equipment used is a Canon RadPro mobile with CXDI-70c wireless DR plate, and the same DR plate on a fixed Siemens Multix unit. Small surgical devices and needles tested include Rubber Shod, Bulldog, Fogarty Hydrogrip, and needles with sizes 3-0 C-T1 through 8-0 BV175-6. They are imaged with PMMA block phantoms with thickness of 2–8 inch, and an abdomen phantom. Various DR techniques are used. Images are reviewed on the portable x-ray acquisition display, a clinical workstation, and a diagnostic workstation. Results: all small surgical devices and needles are visible in portable DR images with 2–8 inch of PMMA. However, when they are imaged with the abdomen phantom plus 2 inch of PMMA, needles smaller than 9.3 mm length can not be visualized at the optimized technique of 81 kV and 16 mAs. There is no significant difference in visualization with various techniques, or between mobile and fixed radiography unit. However, there is noticeable difference in visualizing the smallest needle on a diagnostic reading workstation compared to the acquisition display on a portable x-ray unit. Conclusion: DR images should be reviewed on a diagnostic reading workstation. Using optimized DR techniques, the smallest needle that can be identified on all phantom studies is 9.3 mm. Sample DR images of various small surgical devices/needles available on diagnostic workstation for comparison may improve their identification. Further in vivo study is needed to confirm the optimized digital radiography technique for identification of lost small surgical devices and needles

  9. Distributed mass data acquisition system based on PCs and windows NT for LHD fusion plasma experiment

    International Nuclear Information System (INIS)

    Nakanishi, H.; Kojima, M.; Ohsuna, M.; Komada, S.; Emoto, M.; Sugisaki, H.; Sudo, S.

    2000-12-01

    A new data acquisition and management system has been developed for the LHD experiment. It has the capability to process 100 MB - 1 GB raw data within a few tens seconds after every plasma discharge. It employs wholly distributed and loosely-tied parallel tasking structure through a fast network, and the cluster of the distributed database severs seems to be a virtual macro-machine as a whole. A PC/Windows NT computer is installed for each diagnostics data acquisition of about 30 kinds, and it controls CAMAC digitizers through the optical SCSI extenders. The diagnostic timing system consists of some kinds of VME modules that are installed to remotely control the diagnostic devices in real-time. They can, as a whole system, distribute the synchronous sampling clocks and programmable triggers for measurement digitizers. The data retrieving terminals can access database as application service clients, and are functionally separated from the data acquisition severs by way of the switching Ethernet. (author)

  10. A high throughput data acquisition and processing model for applications based on GPUs

    International Nuclear Information System (INIS)

    Nieto, J.; Arcas, G. de; Ruiz, M.; Castro, R.; Vega, J.; Guillen, P.

    2015-01-01

    Highlights: • Implementation of a direct communication path between a data acquisition NI FlexRIO device and a NVIDIA GPU device. • Customization of a Linux Kernel Open Driver (NI FlexRIO) and a C API Interface for work con NVIDIA RDMA GPUDirect. • Performance evaluation with respect to traditional model that use CPU as buffer data allocation. - Abstract: There is an increasing interest in the use of GPU technologies for real time analysis in fusion devices. The availability of high bandwidth interfaces has made them a very cost effective alternative not only for high volume data analysis or simulation, and commercial products are available for some interest areas. However from the point of view of their application in real time scenarios, there are still some issues under analysis, such as the possibility to improve the data throughput inside a discrete system consisting of data acquisition devices (DAQ) and GPUs. This paper addresses the possibility of using peer to peer data communication between DAQ devices and GPUs sharing the same PCIexpress bus to implement continuous real time acquisition and processing systems where data transfers require minimum CPU intervention. This technology eliminates unnecessary system memory copies and lowers CPU overhead, avoiding bottleneck when the system uses the main system memory.

  11. A high throughput data acquisition and processing model for applications based on GPUs

    Energy Technology Data Exchange (ETDEWEB)

    Nieto, J., E-mail: jnieto@sec.upm.es [Instrumentation and Applied Acoustic Research Group, Technical University of Madrid (UPM), Madrid (Spain); Arcas, G. de; Ruiz, M. [Instrumentation and Applied Acoustic Research Group, Technical University of Madrid (UPM), Madrid (Spain); Castro, R.; Vega, J. [Data acquisition Group EURATOM/CIEMAT Association for Fusion, Madrid (Spain); Guillen, P. [Instrumentation and Applied Acoustic Research Group, Technical University of Madrid (UPM), Madrid (Spain)

    2015-10-15

    Highlights: • Implementation of a direct communication path between a data acquisition NI FlexRIO device and a NVIDIA GPU device. • Customization of a Linux Kernel Open Driver (NI FlexRIO) and a C API Interface for work con NVIDIA RDMA GPUDirect. • Performance evaluation with respect to traditional model that use CPU as buffer data allocation. - Abstract: There is an increasing interest in the use of GPU technologies for real time analysis in fusion devices. The availability of high bandwidth interfaces has made them a very cost effective alternative not only for high volume data analysis or simulation, and commercial products are available for some interest areas. However from the point of view of their application in real time scenarios, there are still some issues under analysis, such as the possibility to improve the data throughput inside a discrete system consisting of data acquisition devices (DAQ) and GPUs. This paper addresses the possibility of using peer to peer data communication between DAQ devices and GPUs sharing the same PCIexpress bus to implement continuous real time acquisition and processing systems where data transfers require minimum CPU intervention. This technology eliminates unnecessary system memory copies and lowers CPU overhead, avoiding bottleneck when the system uses the main system memory.

  12. Development of controller of acquisition and sample positioner for activation for use in measurements of short half-life radioisotopes; Desenvolvimento de dispositivo movimentador automatizado de amostras com vista a aplicacao em medidas de radioisotopos que possuem curto tempo de meia-vida

    Energy Technology Data Exchange (ETDEWEB)

    Secco, Marcello

    2016-08-01

    High resolution gamma spectroscopy measurements have several applications. Those involving short half-life radioisotope measurements may present low precision problems when the radioactive source is far from detector end cup and in the very high activity situations also can present accuracy loss due to dead time and pile-up effects. A way to overcome these problems is changing the source detector distance as the activity is decreasing, and thereby maximizing the statistical counting. In the present study, the Controller of Acquisition and Sample Positioner for Activation (CASPA) was developed. It is a low cost and weight device, made with low atomic number materials designed to assist gamma spectroscopy measurements, which is able to control the distance between the source and the detector, even allowing that there is a change of this distance during the measurement process. Because it is automated it optimizes the time of the operator, who has complete freedom to program their routine measurements in the device besides minimizing the radiation dose in the operator. An interface that allow the user control the CASPA system and to program the acquisition system was created. Tests aiming to optimize the operation of CASPA system were carried out and the safety of the CASPA operation was verified, it was not presented any failure during their tests. It was applied the repeatability tests by the acquisition {sup 60}Co standard source and was found that the positioning of automated system has reproduced the results of static system with a 95% of confidence level. (author)

  13. Daily organ tracking in intensity-modulated radiotherapy of prostate cancer using an electronic portal imaging device with a dose saving acquisition mode

    International Nuclear Information System (INIS)

    Vetterli, Daniel; Thalmann, Sandrine; Behrensmeier, Frank; Kemmerling, Ludger; Born, Ernst J.; Mini, Roberto; Greiner, Richard H.; Aebersold, Daniel M.

    2006-01-01

    Background and purpose: Daily use of conventional electronic portal imaging devices (EPID) for organ tracking is limited due to the relatively high dose required for high quality image acquisition. We studied the use of a novel dose saving acquisition mode (RadMode) allowing to take images with one monitor unit per image in prostate cancer patients undergoing intensity-modulated radiotherapy (IMRT) and tracking of implanted fiducial gold markers. Patients and methods: Twenty five patients underwent implantation of three fiducial gold markers prior to the planning CT. Before each treatment of a course of 37 fractions, orthogonal localization images from the antero-posterior and from the lateral direction were acquired. Portal images of both the setup procedure and the five IMRT treatment beams were analyzed. Results: On average, four localization images were needed for a correct patient setup, resulting in four monitor units extra dose per fraction. The mean extra dose delivered to the patient was thereby increased by 1.2%. The procedure was precise enough to reduce the mean displacements prior to treatment to ≤0.3 mm. Conclusions: The use of a new dose saving acquisition mode enables to perform daily EPID-based prostate tracking with a cumulative extra dose of below 1 Gy. This concept is efficiently used in IMRT-treated patients, where separation of setup beams from treatment beams is mandatory

  14. Construction and calibration of a low cost and fully automated vibrating sample magnetometer

    Science.gov (United States)

    El-Alaily, T. M.; El-Nimr, M. K.; Saafan, S. A.; Kamel, M. M.; Meaz, T. M.; Assar, S. T.

    2015-07-01

    A low cost vibrating sample magnetometer (VSM) has been constructed by using an electromagnet and an audio loud speaker; where both are controlled by a data acquisition device. The constructed VSM records the magnetic hysteresis loop up to 8.3 KG at room temperature. The apparatus has been calibrated and tested by using magnetic hysteresis data of some ferrite samples measured by two scientifically calibrated magnetometers; model (Lake Shore 7410) and model (LDJ Electronics Inc. Troy, MI). Our VSM lab-built new design proved success and reliability.

  15. A VMEbus general-purpose data acquisition system

    International Nuclear Information System (INIS)

    Ninane, A.; Nemry, M.; Martou, J.L.; Somers, F.

    1992-01-01

    We present a general-purpose, VMEbus based, multiprocessor data acquisition and monitoring system. Events, handled by a master CPU, are kept at the disposal of data storage and monitoring processes which can run on distinct processors. They access either the complete set of data or a fraction of them, minimizing the acquisition dead-time. The system is built with the VxWorks 5.0 real time kernel to which we have added device drivers for data acquisition and monitoring. The acquisition is controlled and the data are displayed on a workstation. The user interface is written in C ++ and re-uses the classes of the Interviews and the NIH libraries. The communication between the control workstation and the VMEbus processors is made through SUN RPCs on an Ethernet link. The system will be used for, CAMAC based, data acquisition for nuclear physics experiments as well as for the VXI data taking with the 4π configuration (100 neutron detectors) of the Brussels-Caen-Louvian-Strasbourg DEMON collaboration. (author)

  16. Implementation of synthetic aperture imaging on a hand-held device

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian; Kjeldsen, Thomas; Larsen, Lee

    2014-01-01

    -held devices all with different chipsets and a BK Medical UltraView 800 ultrasound scanner emulating a wireless probe. The wireless transmission is benchmarked using an imaging setup consisting of 269 scan lines x 1472 complex samples (1.58 MB pr. frame, 16 frames per second). The measured data throughput...... reached an average of 28.8 MB/s using a LG G2 mobile device, which is more than the required data throughput of 25.3 MB/s. Benchmarking the processing performance for B-mode imaging showed a total processing time of 18.9 ms (53 frames/s), which is less than the acquisition time (62.5 ms).......This paper presents several implementations of Syn- thetic Aperture Sequential Beamforming (SASB) on commer- cially available hand-held devices. The implementations include real-time wireless reception of ultrasound radio frequency sig- nals and GPU processing for B-mode imaging. The proposed...

  17. Five channel data acquisition system for tracer studies

    International Nuclear Information System (INIS)

    Narender Reddy, J.; Dhananjay Reddy, Y.; Dheeraj Reddy, J.

    2001-01-01

    Radioactive tracers are being used by many modern industries for trouble shooting, process control/quality control and optimization in the process plants. A five channel data acquisition system which has five independent scintillation detector based channels for data acquisition has been developed and made available. This system can be used for tracer studies involving Mean residence time, Resident time distribution and other similar parameters involving tracer movement. System developed can acquire data with dwell times ranging from 10 m sec to 100 sec into each channel and has a capacity to acquire data into 10K channels. Each channel electronics, has a 1x1 NaI Scintillation Detector probe, HV, AMP SCA, micro-controller based data acquisition card with independent dot matrix LCD display for visualization. Extensive use of serial bus (I 2 C, microwire) compatible devices has been incorporated in the design. Data acquisition is initiated simultaneously into all the channels. System design permits delayed/prompt data acquisition selectively. Dual counter switching technique has been employed to achieve faster dwell times for data acquisition. (author)

  18. Electronic module for control of sample feeding device of spectrometers of X-ray fluorescent analysis of CRV type

    International Nuclear Information System (INIS)

    Petrov, V.A.; Fursov, A.V.

    2002-01-01

    The scheme of electronic module for sample feeding device control for the CRV type X-ray fluorescence analysis spectrometers is considered. This module provides realization of next functions: sample change operations and installation in starting position; signaling and defense at emergency cases; indication of any sample amount in the spectrometer chamber; testing function at tuning and testing of modules. All these principal functions are entrusted with microcontroller. Programming of the microcontroller is putting into effect by algorithm of the whole sample feeding device. In the capacity of microcontroller the single crystalline processor PICI16C54 and stepping motor of NV-306-V2202 model have been used

  19. Progress on the data acquisition system at NSCL

    International Nuclear Information System (INIS)

    Fox, R.; Au, R.; Glynn, T.; Pollack, B.; Vander Mulen, A.

    1985-01-01

    We report on the progress made in data acquisition software development. Specifically, a unique generalized data routing scheme has been developed which allows user online analysis programs to be safely integrated into the acquisition system without endangering data sent to event recording devices. We describe the structure of the system. Performance is discussed and throughput calculated from it. User experience with the system is also discussed. We show how this routing system may easily be adapted to loosely coupled multiprocessor systems

  20. Installation and sampling of vadose zone monitoring devices

    International Nuclear Information System (INIS)

    Bergeron, S.M.; Strickland, D.J.; Pearson, R.

    1987-10-01

    A vadose zone monitoring system was installed in a sanitary landfill near the Y-12 facility on the Department of Energy's Oak Ridge, Tennessee Reservation. The work was completed as part of the LLWDDD program to develop, design, and demonstrate new low level radioactive waste disposal monitoring methods. The objective of the project was to evaluate the performance of three types of vadose zone samplers within a similar hydrogeologic environment for use as early detection monitoring devices. The three different types of samplers included the Soil Moisture Equipment Corporation Pressure-Vacuum samplers (Models 1920 and 1940), and the BAT Piezometer (Model MK II) manufactured by BAT Envitech, Inc. All three samplers are designed to remove soil moisture from the vadose (unsaturated) zone. Five clusters of three holes each were drilled to maximum depths of 45 ft around part of the periphery of the landfill. Three samplers, one of each type, were installed at each cluster location. Water samples were obtained from 13 of the 15 samplers and submitted to Martin Marietta for analysis. All three samplers performed satisfactorily when considering ease of installation, required in-hole development, and ability to collect water samples from the vadose zone. Advantages and disadvantages of each sampler type are discussed in the main report

  1. A Low-Cost Modular Platform for Heterogeneous Data Acquisition with Accurate Interchannel Synchronization

    Directory of Open Access Journals (Sweden)

    José Luis Blanco-Claraco

    2015-10-01

    Full Text Available Most experimental fields of science and engineering require the use of data acquisition systems (DAQ, devices in charge of sampling and converting electrical signals into digital data and, typically, performing all of the required signal preconditioning. Since commercial DAQ systems are normally focused on specific types of sensors and actuators, systems engineers may need to employ mutually-incompatible hardware from different manufacturers in applications demanding heterogeneous inputs and outputs, such as small-signal analog inputs, differential quadrature rotatory encoders or variable current outputs. A common undesirable side effect of heterogeneous DAQ hardware is the lack of an accurate synchronization between samples captured by each device. To solve such a problem with low-cost hardware, we present a novel modular DAQ architecture comprising a base board and a set of interchangeable modules. Our main design goal is the ability to sample all sources at predictable, fixed sampling frequencies, with a reduced synchronization mismatch (<1 µs between heterogeneous signal sources. We present experiments in the field of mechanical engineering, illustrating vibration spectrum analyses from piezoelectric accelerometers and, as a novelty in these kinds of experiments, the spectrum of quadrature encoder signals. Part of the design and software will be publicly released online.

  2. CHOMIK -Sampling Device of Penetrating Type for Russian Phobos Sample Return Mission

    Science.gov (United States)

    Seweryn, Karol; Grygorczuk, Jerzy; Rickmann, Hans; Morawski, Marek; Aleksashkin, Sergey; Banaszkiewicz, Marek; Drogosz, Michal; Gurgurewicz, Joanna; Kozlov, Oleg E.; Krolikowska-Soltan, Malgorzata; Sutugin, Sergiej E.; Wawrzaszek, Roman; Wisniewski, Lukasz; Zakharov, Alexander

    Measurements of physical properties of planetary bodies allow to determine many important parameters for scientists working in different fields of research. For example effective heat conductivity of the regolith can help with better understanding of processes occurring in the body interior. Chemical and mineralogical composition gives us a chance to better understand the origin and evolution of the moons. In principle such parameters of the planetary bodies can be determined based on three different measurement techniques: (i) in situ measurements (ii) measurements of the samples in laboratory conditions at the Earth and (iii) remote sensing measurements. Scientific missions which allow us to perform all type of measurements, give us a chance for not only parameters determination but also cross calibration of the instruments. Russian Phobos Sample Return (PhSR) mission is one of few which allows for all type of such measurements. The spacecraft will be equipped with remote sensing instruments like: spectrometers, long wave radar and dust counter, instruments for in-situ measurements -gas-chromatograph, seismometer, thermodetector and others and also robotic arm and sampling device. PhSR mission will be launched in November 2011 on board of a launch vehicle Zenit. About a year later (11 months) the vehicle will reach the Martian orbit. It is anticipated that it will land on Phobos in the beginning of 2013. A take off back will take place a month later and the re-entry module containing a capsule that will hold the soil sample enclosed in a container will be on its way back to Earth. The 11 kg re-entry capsule with the container will land in Kazakhstan in mid-2014. A unique geological penetrator CHOMIK dedicated for the Phobos Sample Return space mis-sion will be designed and manufactured at the Space Mechatronics and Robotics Laboratory, Space Research Centre Polish Academy of Sciences (SRC PAS) in Warsaw. Functionally CHOMIK is based on the well known MUPUS

  3. Graphical user interface for image acquisition and processing

    Science.gov (United States)

    Goldberg, Kenneth A.

    2002-01-01

    An event-driven GUI-based image acquisition interface for the IDL programming environment designed for CCD camera control and image acquisition directly into the IDL environment where image manipulation and data analysis can be performed, and a toolbox of real-time analysis applications. Running the image acquisition hardware directly from IDL removes the necessity of first saving images in one program and then importing the data into IDL for analysis in a second step. Bringing the data directly into IDL creates an opportunity for the implementation of IDL image processing and display functions in real-time. program allows control over the available charge coupled device (CCD) detector parameters, data acquisition, file saving and loading, and image manipulation and processing, all from within IDL. The program is built using IDL's widget libraries to control the on-screen display and user interface.

  4. CAMAC data acquisition system based on micro VAXII

    International Nuclear Information System (INIS)

    Yin Xijin; Shen Cuihua; Bai Xiaowei; Li Weisheng

    1993-01-01

    The CAMAC data acquisition system based on Micro VAXII Computer provides high-speed, Zero-suppressed, and 256-parameter CAMAC acquisition. It consists of three parts: control logic unit, CAMAC readout system and host computer system. When the control logical unit is triggered by external electronic selection signal, it produces a pilot signal to keep all of the parameters of a particular event together. Event-model data have been collected by using a CAMAC Fast Crate controller. The host computer system, in hard environment, is equipped with certain peripheral device. It includes the following: 1. at least two M990 GCR, 6250B/inch, magnetic tape driver operating at 75 inches per second or faster; 2. a Tektronix 4014 storage scope; 3. a laser printer, LND3-AE or copier which is capable of making hard-copies of Tektronix 4014 screen; 4. a control console device and a line printer; 5. x-press color graphics terminal; 6. DEC network. When the system is in real-time acquisition, it is able, on-line, to handle and analyse data stream, to monitor and control experiment and to display dynamically spectra on the Tektronix 4014

  5. Knowledge Capture and Acquisition Mechanisms at Kisii University

    Directory of Open Access Journals (Sweden)

    Nemwel Aming'a

    2015-07-01

    Full Text Available Knowledge management and knowledge assets have gained much prominence in recent years and are said to improve organizational performance. Knowledge capture and acquisition mechanisms enhance organizational memory and performance. However, knowledge capture and acquisition mechanisms in higher education institutions are not well known. The aim of this study was to investigate the knowledge capture and acquisition mechanisms at Kisii University. This was a case study in which data were collected through interviews and questionnaires. Purposive sampling was used to determine interview participants while questionnaire respondents were selected through stratified random sampling. Qualitative and quantitative data were analysed using SPSS® student version 14; it revealed that there were various knowledge capture and acquisition mechanisms at Kisii University. It was also established that the University encountered various challenges in knowledge capture and acquisition and lacked some essential knowledge capture and acquisition mechanisms. In this regard, this study proposed knowledge capture and acquisition guidelines that may be adopted by the University to enhance its organizational memory and performance.

  6. Distributed CAN-BUS-based data acquisition system

    International Nuclear Information System (INIS)

    Orekhov, D.I.; Chepurnov, A.S.; Majmistov, D.I.; Sabel'nikov, A.A.

    2007-01-01

    A distributed remote-control system for large nuclear physical setups is intended to collect, store, and analyze data arriving from detecting devices and to visualize them via the WEB. The system uses the CAN industrial data transmission network and the DeviceNet high-level protocol. The hardware part is the set of controllers, which convert signals of the detecting devices into a frequency and transmit them in the digital form via the CAN network to the host computer. The software realizes the DeviceNet protocol stack, which ensures the data acquisition and transmission. The user interface is based on dynamic WEB pages. The system is used for monitoring dark noises of photomultiplier tubes in the BOREXINO neutrino detector (Italy) [ru

  7. Prose Learning for Veterinary Educators: Facilitating Acquisition

    Science.gov (United States)

    Harkness, John E.

    1978-01-01

    A prose text in veterinary medicine can be arranged and supplemented to facilitate efficient and effective acquisition into short-term memory. Methods include: variation in textual format; relating new information to previous knowledge and future goals; providing specific, test-relevant objectives or introductions, describing mnemonic devices; and…

  8. Acquisition system of tandem injector parameters

    International Nuclear Information System (INIS)

    Decourt, M.

    1986-01-01

    The system centralizes all the parameters belonging to the accelerator injector. The acquisition center system reinforces an original device made of cameras and video receivers. Besides giving access to all the parameters of the ion source, the new system allows, in the ''OSCILLO'' mode, to visualize in real time any channel on the oscilloscope [fr

  9. A distributed, hardware reconfigurable and packet switched real-time control and data acquisition system

    International Nuclear Information System (INIS)

    Batista, A.J.N.; Combo, A.; Sousa, J.; Varandas, C.A.F.

    2002-01-01

    The architecture of a synchronized event-based control and data acquisition system that aims to improve significantly the performance of actual systems is presented. The design explores recent developments in data transport, signal processing and system synchronization. Data transport between the acquisition, processing and storing devices and at backplane level will be performed by InfiniBand, a low latency packet switched network standard. Data processing algorithms will be performed in a mixture of digital signal processors and reconfigurable field programmable gate arrays. Both devices will be programmed from a descriptive high-level mathematical language. Acquisition synchronization, data stamping and event management will be performed through a specialized low latency synchronous optical network for the time critical signals

  10. Device for electrochemical detection of metal sample surface resistance and passivation against corrosion in electrolyte

    International Nuclear Information System (INIS)

    Urbancik, L.; Bar, J.; Nemec, J.; Sima, A.

    1986-01-01

    The device consists of a teflon vessel with sealing and an opening below the electrolyte level. Into it is submerged an electrode connected to a dc voltage supply whose other pole is connected to a sample of the metal which is pressed to the opening in the sealing with a flexible strap. The teflon vessel and the sealing are integral. The device is simpler and less costly than those manufactured so far. The operating capability of damaged sealing may be renewed by simple mechanical working. The device may be used for detecting the resistance and passivation of steam generator metal tubes. (J.B.). 1 fig

  11. Transdermal microconduits by microscission for drug delivery and sample acquisition

    Directory of Open Access Journals (Sweden)

    Anderson R

    2004-04-01

    Full Text Available Abstract Background Painless, rapid, controlled, minimally invasive molecular transport across human skin for drug delivery and analyte acquisition is of widespread interest. Creation of microconduits through the stratum corneum and epidermis is achieved by stochastic scissioning events localized to typically 250 μm diameter areas of human skin in vivo. Methods Microscissioning is achieved by a limited flux of accelerated gas: 25 μm inert particles passing through the aperture in a mask held against the stratum corneum. The particles scize (cut tissue, which is removed by the gas flow with the sensation of a gentle stream of air against the skin. The resulting microconduit is fully open and may be between 50 and 200 μm deep. Results In vivo adult human tests show that microconduits reduce the electrical impedance between two ECG electrodes from approximately 4,000 Ω to 500 Ω. Drug delivery has been demonstrated in vivo by applying lidocaine to a microconduit from a cotton swab. Sharp point probing demonstrated full anaesthesia around the site within three minutes. Topical application without the microconduit required approximately 1.5 hours. Approximately 180 μm deep microconduits in vivo yielded blood sample volumes of several μl, with a faint pricking sensation as blood enters tissue. Blood glucose measurements were taken with two commercial monitoring systems. Microconduits are invisible to the unaided eye, developing a slight erythematous macule that disappears over days. Conclusion Microscissioned microconduits may provide a minimally invasive basis for delivery of any size molecule, and for extraction of interstitial fluid and blood samples. Such microconduits reduce through-skin electrical impedance, have controllable diameter and depth, are fully open and, after healing, no foreign bodies were visible using through-skin confocal microscopy. In subjects to date, microscissioning is painless and rapid.

  12. Laser ignition device and its application to forestry, fire and land management

    International Nuclear Information System (INIS)

    Waterworth, M.D.

    1987-01-01

    A laser ignition device for controlled burning of forest logging slash has been developed and successfully tested. The device, which uses a kilowatt class carbon dioxide laser, operates at distances of 50 to 1500 meters. Acquisition and focus control are achieved by the use of a laser rangefinder and acquisition telescope. Additional uses for the device include back burning, selected undergrowth removal, safe ignition of oil spills, and deicing. A truck mounted version will be operational by fall 1987 and an airborne version by summer 1988. (author)

  13. Laser ignition device and its application to forestry, fire and land management

    Energy Technology Data Exchange (ETDEWEB)

    Waterworth, M. D.

    1987-11-15

    A laser ignition device for controlled burning of forest logging slash has been developed and successfully tested. The device, which uses a kilowatt class carbon dioxide laser, operates at distances of 50 to 1500 meters. Acquisition and focus control are achieved by the use of a laser rangefinder and acquisition telescope. Additional uses for the device include back burning, selected undergrowth removal, safe ignition of oil spills, and deicing. A truck mounted version will be operational by fall 1987 and an airborne version by summer 1988. (author)

  14. Microcomputer data acquisition and control.

    Science.gov (United States)

    East, T D

    1986-01-01

    In medicine and biology there are many tasks that involve routine well defined procedures. These tasks are ideal candidates for computerized data acquisition and control. As the performance of microcomputers rapidly increases and cost continues to go down the temptation to automate the laboratory becomes great. To the novice computer user the choices of hardware and software are overwhelming and sadly most of the computer sales persons are not at all familiar with real-time applications. If you want to bill your patients you have hundreds of packaged systems to choose from; however, if you want to do real-time data acquisition the choices are very limited and confusing. The purpose of this chapter is to provide the novice computer user with the basics needed to set up a real-time data acquisition system with the common microcomputers. This chapter will cover the following issues necessary to establish a real time data acquisition and control system: Analysis of the research problem: Definition of the problem; Description of data and sampling requirements; Cost/benefit analysis. Choice of Microcomputer hardware and software: Choice of microprocessor and bus structure; Choice of operating system; Choice of layered software. Digital Data Acquisition: Parallel Data Transmission; Serial Data Transmission; Hardware and software available. Analog Data Acquisition: Description of amplitude and frequency characteristics of the input signals; Sampling theorem; Specification of the analog to digital converter; Hardware and software available; Interface to the microcomputer. Microcomputer Control: Analog output; Digital output; Closed-Loop Control. Microcomputer data acquisition and control in the 21st Century--What is in the future? High speed digital medical equipment networks; Medical decision making and artificial intelligence.

  15. Incore instrumentation device

    International Nuclear Information System (INIS)

    Fujita, Kazuhiko.

    1996-01-01

    A position of a detector is detected by a driving device, and the detected values are sampled by a newly disposed central processing unit for sampling the detected values depending on the sampling position of the detected values. Since the sampling position of the detected values is detected by the driving device, the sampling position for the detection values does not rely on the speed of the driving motor of the driving device. The load on the central processing device for controlling the device is lowered by newly disposing the central processing unit for sampling detected values. When the values for the position of the detector counted after conversion to digital values reach the digital values corresponding to the detection value sampling position outputted from the central processing unit for controlling the device, a counted value comparison circuit causes the central processing unit for controlling the device to sample the detection values outputted from the detector. Then, the processing speed can be increased without interruption processings, which can save the central processing unit for sampling detection values. In addition, software can be simplified and loads can be lowered. (N.H.)

  16. Human Robotic Systems (HRS): Robotic ISRU Acquisition Element

    Data.gov (United States)

    National Aeronautics and Space Administration — During 2014, the Robotic ISRU Resource Acquisition project element will develop two technologies:Exploration Ground Data Systems (xGDS)Sample Acquisition on...

  17. Integration of continuous-flow sampling with microchip electrophoresis using poly(dimethylsiloxane)-based valves in a reversibly sealed device.

    Science.gov (United States)

    Li, Michelle W; Martin, R Scott

    2007-07-01

    Here we describe a reversibly sealed microchip device that incorporates poly(dimethylsiloxane) (PDMS)-based valves for the rapid injection of analytes from a continuously flowing stream into a channel network for analysis with microchip electrophoresis. The microchip was reversibly sealed to a PDMS-coated glass substrate and microbore tubing was used for the introduction of gas and fluids to the microchip device. Two pneumatic valves were incorporated into the design and actuated on the order of hundreds of milliseconds, allowing analyte from a continuously flowing sampling stream to be injected into an electrophoresis separation channel. The device was characterized in terms of the valve actuation time and pushback voltage. It was also found that the addition of sodium dodecyl sulfate (SDS) to the buffer system greatly increased the reproducibility of the injection scheme and enabled the analysis of amino acids derivatized with naphthalene-2,3-dicarboxaldehyde/cyanide. Results from continuous injections of a 0.39 nL fluorescein plug into the optimized system showed that the injection process was reproducible (RSD of 0.7%, n = 10). Studies also showed that the device was capable of monitoring off-chip changes in concentration with a device lag time of 90 s. Finally, the ability of the device to rapidly monitor on-chip concentration changes was demonstrated by continually sampling from an analyte plug that was derivatized upstream from the electrophoresis/continuous flow interface. A reversibly sealed device of this type will be useful for the continuous monitoring and analysis of processes that occur either off-chip (such as microdialysis sampling) or on-chip from other integrated functions.

  18. Wireless Data Acquisition of Transient Signals for Mobile Spectrometry Applications.

    Science.gov (United States)

    Trzcinski, Peter; Weagant, Scott; Karanassios, Vassili

    2016-05-01

    Wireless data acquisition using smartphones or handhelds offers increased mobility, it provides reduced size and weight, it has low electrical power requirements, and (in some cases) it has an ability to access the internet. Thus, it is well suited for mobile spectrometry applications using miniaturized, field-portable spectrometers, or detectors for chemical analysis in the field (i.e., on-site). There are four main wireless communications standards that can be used for wireless data acquisition, namely ZigBee, Bluetooth, Wi-Fi, and UWB (ultra-wide band). These are briefly reviewed and are evaluated for applicability to data acquisition of transient signals (i.e., time-domain) in the field (i.e., on-site) from a miniaturized, field-portable photomultiplier tube detector and from a photodiode array detector installed in a miniaturized, field-portable fiber optic spectrometer. These are two of the most widely used detectors for optical measurements in the ultraviolet-visible range of the spectrum. A miniaturized, 3D-printed, battery-operated microplasma-on-a-chip was used for generation of transient optical emission signals. Elemental analysis from liquid microsamples, a microplasma, and a handheld or a smartphone will be used as examples. Development and potential applicability of wireless data acquisition of transient optical emission signals for taking part of the lab to the sample types of mobile, field-portable spectrometry applications will be discussed. The examples presented are drawn from past and ongoing work in the authors' laboratory. A handheld or a smartphone were used as the mobile computing devices of choice. © The Author(s) 2016.

  19. 3D site specific sample preparation and analysis of 3D devices (FinFETs) by atom probe tomography.

    Science.gov (United States)

    Kambham, Ajay Kumar; Kumar, Arul; Gilbert, Matthieu; Vandervorst, Wilfried

    2013-09-01

    With the transition from planar to three-dimensional device architectures such as Fin field-effect-transistors (FinFETs), new metrology approaches are required to meet the needs of semiconductor technology. It is important to characterize the 3D-dopant distributions precisely as their extent, positioning relative to gate edges and absolute concentration determine the device performance in great detail. At present the atom probe has shown its ability to analyze dopant distributions in semiconductor and thin insulating materials with sub-nm 3D-resolution and good dopant sensitivity. However, so far most reports have dealt with planar devices or restricted the measurements to 2D test structures which represent only limited challenges in terms of localization and site specific sample preparation. In this paper we will discuss the methodology to extract the dopant distribution from real 3D-devices such as a 3D-FinFET device, requiring the sample preparation to be carried out at a site specific location with a positioning accuracy ∼50 nm. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. High sensitivity high-resolution full range relaxometry using a fast mechanical sample shuttling device and a cryo-probe

    Energy Technology Data Exchange (ETDEWEB)

    Chou, Ching-Yu [Université Paris-Saclay, NIMBE, CEA, CNRS (France); Chu, Minglee [Academia Sinica, Institute of Physics (China); Chang, Chi-Fon [Academia Sinica, Genomics Research Center (China); Yu, Tsunai; Huang, Tai-huang, E-mail: bmthh@gate.sinica.edu.tw [Academia Sinica, Institute of Biomedical Science (China); Sakellariou, Dimitris, E-mail: dimitrios.sakellariou@cea.fr [Université Paris-Saclay, NIMBE, CEA, CNRS (France)

    2016-11-15

    Field-dependent NMR studies of bio-molecular systems using a sample shuttling hardware operating on a high-field NMR apparatus have provided valuable structural and dynamic information. We have recently published a design of a compact sample transportation device, called “field-cycler”, which was installed in a commercial spectrometer and which provided highly precise positioning and stability during high speed shuttling. In this communication, we demonstrate the first use of a sample shuttling device on a commercial high field standard bore NMR spectrometer, equipped with a commercial triple resonance cryogenically cooled NMR probe. The performance and robustness of the hardware operating in 1D and 2D field cycling experiments, as well as the impact of the sample shuttling time on the signal intensity are discussed.

  1. Concept for a Microcontroller Based Data Acquisition Device for Use in Nuclear Environments Measuring and Monitoring

    International Nuclear Information System (INIS)

    Stratton, Sam; Stevenson, Dave; Magnifico, Matteo

    2013-06-01

    Micro-controllers, (which are a superset of microprocessors), usually include a microprocessor, RAM, nonvolatile memory and an interface controller all on a single chip. Micro-controllers are widely used in what are known as 'embedded systems'. An embedded system is designed for a specific function often in a larger overall system. Where the home PC is designed for flexibility and many different types of software applications, embedded systems are most often fixed in their functionality and typically will not change during the life of their implementation. By the same token, the software developed for a micro-controller will not typically change during device deployment and is therefore called 'firmware'. A Data Acquisition (DAQ) micro-controller will also include an Analog to Digital Converter (ADC) on the chip. The current state of nuclear power plant control systems is somewhat antiquated and even though there have been great strides made in the upgrade of Nuclear Power Plant (NPP) systems, the industry as a whole has been slow to adopt the latest in technology. The benefits of digital technology are widely recognized in the NPP industry and yet adoption has still been slow due at least to some degree by the significant safety concerns of the industry. Results in other industries including satellite manufacture however, have shown that risk can be managed and high reliability achieved to produce electronics that function without errors for many years. In addition, the catastrophe that occurred at the Fukushima Daiichi plant is causing some in the NPP industry to consider electronics that can withstand severe radiation and temperature conditions. The technology exists today to develop a single chip micro-controller data acquisition system that can survive and function reliably in radiation and other harsh environments and would be suitable for implementation in an NPP system. (authors)

  2. Recent developments of the RFX control and data acquisition system

    International Nuclear Information System (INIS)

    Barana, O.; Luchetta, A.; Manduchi, G.; Taliercio, C.

    2004-01-01

    Although the new RFX machine is still under modification, most power supply systems have been used since early 2003 for testing an ITER high-power by-pass switch. This has given us the opportunity to verify the effectiveness of several choices we made in the development of the new data acquisition and control system of RFX. The system has been renewed both in its control and data acquisition components. For control, the new system employs Simatic S7 PLCs and a commercial Supervisory Control and Data Acquisition (SCADA) tool. Many improvements have been made to the MDSplus-based data acquisition system. The whole system has been ported from OpenVMS to Linux, using a server for data storage and CAMAC data acquisition, and a set of CompactPCI crates, each hosting a Linux PC board. Device-specific code is now entirely implemented in TDI, the scripting language of MDSplus. Our experience in the new system has been positive, especially for the data acquisition system

  3. Sampling inspection device

    International Nuclear Information System (INIS)

    Chiba, Keiichi.

    1996-01-01

    A holder is inserted to a holder guide, and is stopped at a position where one end of a hook disposed to the holder is not in contact with the holder guide (a position where hooks do not work). A cap incorporated with wiping paper is pushed up into a holder by a device rod with the wiping paper situated downwardly. The hooks of the holder are engaged to the grooves of the cap to secure the cap. The holder is moved to a predetermined place to wipe off the deposited materials on the surface of a vessel which contains radioactive wastes. Then, the holder is inserted to the holder guide, and is stopped at a position where the one end of the holder is raised. The securement of the gap is released, the cap is forced into a recovering cover by a discharging rod. The hooks of the recovering cover are caught by the grooves of the cap to secure the cap. Then, the cap is transported to a radioactivity measuring chamber. (I.N.)

  4. Method and device for fast code acquisition in spread spectrum receivers

    NARCIS (Netherlands)

    Coenen, A.J.R.M.

    1993-01-01

    Abstract of NL 9101155 (A) Method for code acquisition in a satellite receiver. The biphase-modulated high-frequency carrier transmitted by a satellite is converted via a fixed local oscillator frequency down to the baseband, whereafter the baseband signal is fed via a bandpass filter, which has an

  5. SCI based data acquisition architectures

    International Nuclear Information System (INIS)

    Bogaerts, J.A.C.; Divia, R.; Renardy, J.F.

    1992-01-01

    This paper discusses the Scalable Coherent Interface (SCI), an IEEE proposed standard (P1596) for interconnecting multiprocessor systems. The standard defines point to point connections between nodes, which can be processors, memories or I/O devices. Networks containing a maximum of 64K nodes with a bandwidth of one Gbyte/s between nodes, may be constructed. SCI is an attractive candidate to serve as a backbone for high speed, large volume data acquisition systems such as required by future experiments at the proposed Large Hadron Collider (LHC) at CERN. Work has started to simulate SCI based architectures for data acquisition systems. The simulation program proved to be a useful tool to study SCI systems. First results are reported on a model of a large LHC experiment containing over 1000 nodes

  6. [A capillary blood flow velocity detection system based on linear array charge-coupled devices].

    Science.gov (United States)

    Zhou, Houming; Wang, Ruofeng; Dang, Qi; Yang, Li; Wang, Xiang

    2017-12-01

    In order to detect the flow characteristics of blood samples in the capillary, this paper introduces a blood flow velocity measurement system based on field-programmable gate array (FPGA), linear charge-coupled devices (CCD) and personal computer (PC) software structure. Based on the analysis of the TCD1703C and AD9826 device data sheets, Verilog HDL hardware description language was used to design and simulate the driver. Image signal acquisition and the extraction of the real-time edge information of the blood sample were carried out synchronously in the FPGA. Then a series of discrete displacement were performed in a differential operation to scan each of the blood samples displacement, so that the sample flow rate could be obtained. Finally, the feasibility of the blood flow velocity detection system was verified by simulation and debugging. After drawing the flow velocity curve and analyzing the velocity characteristics, the significance of measuring blood flow velocity is analyzed. The results show that the measurement of the system is less time-consuming and less complex than other flow rate monitoring schemes.

  7. An efficient, robust, and inexpensive grinding device for herbal samples like Cinchona bark

    DEFF Research Database (Denmark)

    Hansen, Steen Honoré; Holmfred, Else Skovgaard; Cornett, Claus

    2015-01-01

    An effective, robust, and inexpensive grinding device for the grinding of herb samples like bark and roots was developed by rebuilding a commercially available coffee grinder. The grinder was constructed to be able to provide various particle sizes, to be easy to clean, and to have a minimum...... of dead volume. The recovery of the sample when grinding as little as 50 mg of crude Cinchona bark was about 60%. Grinding is performed in seconds with no rise in temperature, and the grinder is easily disassembled to be cleaned. The influence of the particle size of the obtained powders on the recovery...

  8. Expansion of the data acquisition system for the 20 MV tandem accelerator

    International Nuclear Information System (INIS)

    Tomita, Yoshiaki

    1981-02-01

    This report describes an expansion of the program of the data acquisition system for the 20 MV tandem accelerator. By the present expansion it became possible to change the accuisition mode or to use non-standard CAMAC modules with partial modification of the program according to well defined prescriptions. The modification can be made by writing microprograms for the MBD or appending subroutines for the reduced spectra in the LIST mode data acquisition. The new program can handle up to 32 ADC's in the standard LIST mode data acquisition. The present expansion aimed to increase the flexibility in data acquisition. It can also be applied to control experimental devices. (author)

  9. Microprocessor system for data acquisition and processing for the Flora device

    International Nuclear Information System (INIS)

    Klimov, V.M.

    1986-01-01

    ''VEhFORMIKA'' microprocessor system for data collection and processing when conducting experiments at the ''Flora'' device is described, its application is grounded. The complex allows one to conduct investigations using multichannel methods and exercise the device electrophysical control

  10. Amplitudes, acquisition and imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bloor, Robert

    1998-12-31

    Accurate seismic amplitude information is important for the successful evaluation of many prospects and the importance of such amplitude information is increasing with the advent of time lapse seismic techniques. It is now widely accepted that the proper treatment of amplitudes requires seismic imaging in the form of either time or depth migration. A key factor in seismic imaging is the spatial sampling of the data and its relationship to the imaging algorithms. This presentation demonstrates that acquisition caused spatial sampling irregularity can affect the seismic imaging and perturb amplitudes. Equalization helps to balance the amplitudes, and the dealing strategy improves the imaging further when there are azimuth variations. Equalization and dealiasing can also help with the acquisition irregularities caused by shot and receiver dislocation or missing traces. 2 refs., 2 figs.

  11. Data acquisition and PV module power production in upgraded TEP/AzRISE solar test yard

    Science.gov (United States)

    Bennett, Whit E.; Fishgold, Asher D.; Lai, Teh; Potter, Barrett G.; Simmons-Potter, Kelly

    2017-08-01

    The Tucson Electric Power (TEP)/University of Arizona AzRISE (Arizona Research Institute for Solar Energy) solar test yard is continuing efforts to improve standardization and data acquisition reliability throughout the facility. Data reliability is ensured through temperature-insensitive data acquisition devices with battery backups in the upgraded test yard. Software improvements allow for real-time analysis of collected data, while uploading to a web server. Sample data illustrates high fidelity monitoring of the burn-in period of a polycrystalline silicon photovoltaic module test string with no data failures over 365 days of data collection. In addition to improved DAQ systems, precision temperature monitoring has been implemented so that PV module backside temperatures are routinely obtained. Weather station data acquired at the test yard provides local ambient temperature, humidity, wind speed, and irradiance measurements that have been utilized to enable characterization of PV module performance over an extended test period

  12. POLYP: an automatic device for drawing sequential samples of gas

    Energy Technology Data Exchange (ETDEWEB)

    Gaglione, P; Koechler, C; Stanchi, L

    1974-12-01

    Polyp is an automatic device consisting of electronic equipment which drives sequentially 8 small pumps for drawing samples of gas. The electronic circuit is driven by a quartz oscillator and allows for the preselection of a waiting time in such a manner that a set of similar instruments placed in suitable position in the open country will start simultaneously. At the same time the first pump of each instrument will inflate a plastic bag for a preset time. The other seven pumps will inflate sequentially the other bags. The instrument is powered by rechargeable batteries and realized with C-MUS integrated circuits for a nearly negligible consumption. As it is foreseen for field operation it is waterproof.

  13. POLYP: an automatic device for drawing sequential samples of gas

    International Nuclear Information System (INIS)

    Gaglione, P.; Koechler, C.; Stanchi, L.

    1974-12-01

    POLYP is an automatic device consisting of an electronic equipment which drives sequentially 8 small pumps for drawing samples of gas. The electronic circuit is driven by a quartz oscillator and allows for the preselection of a waiting time in such a manner that a set of similar instruments placed in suitable position in the open country will start simultaneously. At the same time the first pump of each instrument will inflate a plastic bag for a preset time. Thereafter the other seven pumps will inflate sequentially the other bag. The instrument is powered by rechargeable batteries and realized with C-MOS integrated circuits for a nearly negligible consumption. As it is foreseen for field operation it is waterproof

  14. Complexity in language acquisition.

    Science.gov (United States)

    Clark, Alexander; Lappin, Shalom

    2013-01-01

    Learning theory has frequently been applied to language acquisition, but discussion has largely focused on information theoretic problems-in particular on the absence of direct negative evidence. Such arguments typically neglect the probabilistic nature of cognition and learning in general. We argue first that these arguments, and analyses based on them, suffer from a major flaw: they systematically conflate the hypothesis class and the learnable concept class. As a result, they do not allow one to draw significant conclusions about the learner. Second, we claim that the real problem for language learning is the computational complexity of constructing a hypothesis from input data. Studying this problem allows for a more direct approach to the object of study--the language acquisition device-rather than the learnable class of languages, which is epiphenomenal and possibly hard to characterize. The learnability results informed by complexity studies are much more insightful. They strongly suggest that target grammars need to be objective, in the sense that the primitive elements of these grammars are based on objectively definable properties of the language itself. These considerations support the view that language acquisition proceeds primarily through data-driven learning of some form. Copyright © 2013 Cognitive Science Society, Inc.

  15. Economic benefits of safety-engineered sharp devices in Belgium - a budget impact model.

    Science.gov (United States)

    Hanmore, Emma; Maclaine, Grant; Garin, Fiona; Alonso, Alexander; Leroy, Nicolas; Ruff, Lewis

    2013-11-25

    Measures to protect healthcare workers where there is risk of injury or infection from medical sharps became mandatory in the European Union (EU) from May 2013. Our research objective was to estimate the net budget impact of introducing safety-engineered devices (SEDs) for prevention of needlestick injuries (NSIs) in a Belgian hospital. A 5-year incidence-based budget impact model was developed from the hospital inpatient perspective, comparing costs and outcomes with SEDs and prior-used conventional (non-safety) devices. The model accounts for device acquisition costs and costs of NSI management in 4 areas of application where SEDs are currently used: blood collection, infusion, injection and diabetes insulin administration. Model input data were sourced from the Institut National d'Assurance Maladie-Invalidité, published studies, clinical guidelines and market research. Costs are discounted at 3%. For a 420-bed hospital, 100% substitution of conventional devices by SEDs is estimated to decrease the cumulative 5-year incidence of NSIs from 310 to 75, and those associated with exposure to blood-borne viral diseases from 60 to 15. Cost savings from managing fewer NSIs more than offset increased device acquisition costs, yielding estimated 5-year overall savings of €51,710. The direction of these results is robust to a range of sensitivity and model scenario analyses. The model was most sensitive to variation in the acquisition costs of SEDs, rates of NSI associated with conventional devices, and the acquisition costs of conventional devices. NSIs are a significant potential risk with the use of sharp devices. The incidence of NSIs and the costs associated with their management can be reduced through the adoption of safer work practices, including investment in SEDs. For a Belgian hospital, the budget impact model reports that the incremental acquisition costs of SEDs are offset by the savings from fewer NSIs. The availability of more robust data for NSI reduction

  16. Acquisition system testing with superfluid helium

    International Nuclear Information System (INIS)

    Anderson, J.E.; Fester, D.A.; DiPirro, M.J.

    1988-01-01

    NASA is evaluating both a thermomechanical pump and centrifugal pump for the SHOOT experiment using capillary fluid acquisition systems. Tests were conducted for these systems with superfluid helium under adverse operating conditions. Minus one-g outflow tests were run in conjunction with the thermomechanical pump. Both fine mesh screen and porous sponges were tested. A screen acquisition device was also tested with the low-NPSH centrifugal pump. Results to date show that the screen and sponge are capable of supplying superfluid helium to the thermomechanical pump inlet against a one-g head up to four cm. This is more than sufficient for the SHOOT application. Results with the sponge were reproducible while those with the screen could not always be repeated

  17. In planta passive sampling devices for assessing subsurface chlorinated solvents.

    Science.gov (United States)

    Shetty, Mikhil K; Limmer, Matt A; Waltermire, Kendra; Morrison, Glenn C; Burken, Joel G

    2014-06-01

    Contaminant concentrations in trees have been used to delineate groundwater contaminant plumes (i.e., phytoscreening); however, variability in tree composition hinders accurate measurement of contaminant concentrations in planta, particularly for long-term monitoring. This study investigated in planta passive sampling devices (PSDs), termed solid phase samplers (SPSs) to be used as a surrogate tree core. Characteristics studied for five materials included material-air partitioning coefficients (Kma) for chlorinated solvents, sampler equilibration time and field suitability. The materials investigated were polydimethylsiloxane (PDMS), low-density polyethylene (LDPE), linear low-density polyethylene (LLDPE), polyoxymethylene (POM) and plasticized polyvinyl chloride (PVC). Both PDMS and LLDPE samplers demonstrated high partitioning coefficients and diffusivities and were further tested in greenhouse experiments and field trials. While most of the materials could be used for passive sampling, the PDMS SPSs performed best as an in planta sampler. Such a sampler was able to accurately measure trichloroethylene (TCE) and tetrachloroethylene (PCE) concentrations while simultaneously incorporating simple operation and minimal impact to the surrounding property and environment. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. A novel device for batch-wise isolation of α-cellulose from small-amount wholewood samples

    OpenAIRE

    T. Wieloch; Gerhard Helle; Ingo Heinrich; Michael Voigt; P. Schyma

    2011-01-01

    A novel device for the chemical isolation of α-cellulose from wholewood material of tree rings was designed by the Potsdam Dendro Laboratory. It allows the simultaneous treatment of up to several hundred micro samples. Key features are the batch-wise exchange of the chemical solutions, the reusability of all major parts and the easy and unambiguous labelling of each individual sample. Compared to classical methods labour intensity and running costs are significantly reduced.

  19. Novel device to sample the esophageal microbiome--the esophageal string test.

    Directory of Open Access Journals (Sweden)

    Sophie A Fillon

    Full Text Available A growing number of studies implicate the microbiome in the pathogenesis of intestinal inflammation. Previous work has shown that adults with esophagitis related to gastroesophageal reflux disease have altered esophageal microbiota compared to those who do not have esophagitis. In these studies, sampling of the esophageal microbiome was accomplished by isolating DNA from esophageal biopsies obtained at the time of upper endoscopy. The aim of the current study was to identify the esophageal microbiome in pediatric individuals with normal esophageal mucosa using a minimally invasive, capsule-based string technology, the Enterotest™. We used the proximal segment of the Enterotest string to sample the esophagus, and term this the "Esophageal String Test" (EST. We hypothesized that the less invasive EST would capture mucosal adherent bacteria present in the esophagus in a similar fashion as mucosal biopsy. EST samples and mucosal biopsies were collected from children with no esophageal inflammation (n = 15 and their microbiome composition determined by 16S rRNA gene sequencing. Microbiota from esophageal biopsies and ESTs produced nearly identical profiles of bacterial genera and were different from the bacterial contents of samples collected from the nasal and oral cavity. We conclude that the minimally invasive EST can serve as a useful device for study of the esophageal microbiome.

  20. Multiscattering illumination in blended acquisition

    NARCIS (Netherlands)

    Berkhout, A.J.; Blacquiere, G.; Verschuur, D.J.

    2012-01-01

    In traditional seismic surveys, the firing time between shots is such that the shot records do not interfere in time. However, in the concept of blended acquisition, the records do overlap, allowing denser source sampling and wider azimuths in an economic way. A denser shot sampling and wider

  1. Liquid waste sampling device

    International Nuclear Information System (INIS)

    Kosuge, Tadashi

    1998-01-01

    A liquid pumping pressure regulator is disposed on the midway of a pressure control tube which connects the upper portion of a sampling pot and the upper portion of a liquid waste storage vessel. With such a constitution, when the pressure in the sampling pot is made negative, and liquid wastes are sucked to the liquid pumping tube passing through the sampling pot, the difference between the pressure on the entrance of the liquid pumping pressure regulator of the pressure regulating tube and the pressure at the bottom of the liquid waste storage vessel is made constant. An opening degree controlling meter is disposed to control the degree of opening of a pressure regulating valve for sending actuation pressurized air to the liquid pumping pressure regulator. Accordingly, even if the liquid level of liquid wastes in the liquid waste storage vessel is changed, the height for the suction of the liquid wastes in the liquid pumping tube can be kept constant. With such procedures, sampling can be conducted correctly, and the discharge of the liquid wastes to the outside can be prevented. (T.M.)

  2. Clauser-Horne-Shimony-Holt versus three-party pseudo-telepathy: on the optimal number of samples in device-independent quantum private query

    Science.gov (United States)

    Basak, Jyotirmoy; Maitra, Subhamoy

    2018-04-01

    In device-independent (DI) paradigm, the trustful assumptions over the devices are removed and CHSH test is performed to check the functionality of the devices toward certifying the security of the protocol. The existing DI protocols consider infinite number of samples from theoretical point of view, though this is not practically implementable. For finite sample analysis of the existing DI protocols, we may also consider strategies for checking device independence other than the CHSH test. In this direction, here we present a comparative analysis between CHSH and three-party Pseudo-telepathy game for the quantum private query protocol in DI paradigm that appeared in Maitra et al. (Phys Rev A 95:042344, 2017) very recently.

  3. Trends in monitoring pharmaceuticals and personal-care products in the aquatic environment by use of passive sampling devices

    Science.gov (United States)

    Mills, G.A.; Vrana, B.; Allan, I.; Alvarez, D.A.; Huckins, J.N.; Greenwood, R.

    2007-01-01

    The use of passive sampling in monitoring pharmaceuticals and personal-care products (PPCPs) in the aquatic environment is discussed. The utility of passive sampling methods for monitoring the fraction of heavy metals and the biologically available fraction of non-polar organic priority pollutants is recognized and these technologies are being used in surveys of water quality. These devices are used to measure the dissolved fraction and they can yield information that can be used in the development of risk assessments models. These devices can also be used to locate illegal dumping and to monitor specific sources of input of PPCPs into the environment, or to monitor the effectiveness of water treatment processes in the removal of these compounds from wastewater. These devices can provide representative information at low cost which necessitate a combination of laboratory calibration and field studies for emerging pollutants.

  4. Characteristics of Marijuana Acquisition among a National Sample of Adolescent Users

    Science.gov (United States)

    King, Keith A.; Merianos, Ashley L.; Vidourek, Rebecca A.

    2016-01-01

    Background: Because marijuana is becoming more accessible and perceived norms of use are becoming increasingly more favorable, research is needed to understand characteristics of marijuana acquisition among adolescents. Purpose: The study purpose was to examine whether sources and locations where adolescent users obtain and use marijuana differed…

  5. Design of the data acquisition and analysis system for RFX

    International Nuclear Information System (INIS)

    Flor, G.

    1986-01-01

    This paper describes the conceptual design of the data acquisition and analysis system for the RFX experiment. In order to adequately describe an intrinsically dynamic experiment, the concept of an experiment's model is introduced. The model is generated by means of a suitable experiment description language; the diagnostic system is represented as a tree structure and is described by defining all the data and devices involved in the data acquisition system. The resulting data structures drive the data acquisition process and can be used, with minor modifications, as data descriptions in the archiving system. The need of a generalized I/O system is envisaged and a way to implement it is outlined

  6. Devices used by automated milking systems are similarly accurate in estimating milk yield and in collecting a representative milk sample compared with devices used by farms with conventional milk recording

    NARCIS (Netherlands)

    Kamphuis, Claudia; Dela Rue, B.; Turner, S.A.; Petch, S.

    2015-01-01

    Information on accuracy of milk-sampling devices used on farms with automated milking systems (AMS) is essential for development of milk recording protocols. The hypotheses of this study were (1) devices used by AMS units are similarly accurate in estimating milk yield and in collecting

  7. Data acquisition system for radiographic imaging

    International Nuclear Information System (INIS)

    Lanza, R.C.; Votano, J.R.; Russ, T.

    1992-01-01

    This patent describes a continuous data acquisition system for radiographic imaging without interrupting acquisition activity the acquisition system. It comprises at least two memory means for storing radiographic data from a radiation detector wherein each of the memory means having a plurality of addressable memory locations and each of the memory means are such that the locations of the memory means correspond to spatial locations in the radiation detector; logic control means for sensing radiographic data transmitted by the radiation detector, for selecting one of the memory means for storage of the data, for transferring data to the selected memory means, and for switching form one memory means to another memory means according to a predefined schedule and according to memory capacity level, the logic control means further comprising a logic device which receives data and increments the contents of locations in a memory means in response to such data; and interface control means for reading data from one or the other memory means when such memory means is not actively acquiring data such that data can be acquired continuously by the system

  8. Microwave heating device for internal heating convection experiments, applied to Earth's mantle dynamics.

    Science.gov (United States)

    Surducan, E; Surducan, V; Limare, A; Neamtu, C; Di Giuseppe, E

    2014-12-01

    We report the design, construction, and performances of a microwave (MW) heating device for laboratory experiments with non-contact, homogeneous internal heating. The device generates MW radiation at 2.47 GHz from a commercial magnetron supplied by a pulsed current inverter using proprietary, feedback based command and control hardware and software. Specially designed MW launchers direct the MW radiation into the sample through a MW homogenizer, devised to even the MW power distribution into the sample's volume. An adjustable MW circuit adapts the MW generator to the load (i.e., the sample) placed in the experiment chamber. Dedicated heatsinks maintain the MW circuits at constant temperature throughout the experiment. Openings for laser scanning for image acquisition with a CCD camera and for the cooling circuits are protected by special MW filters. The performances of the device are analyzed in terms of heating uniformity, long term output power stability, and load matching. The device is used for small scale experiments simulating Earth's mantle convection. The 30 × 30 × 5 cm(3) convection tank is filled with a water‑based viscous fluid. A uniform and constant temperature is maintained at the upper boundary by an aluminum heat exchanger and adiabatic conditions apply at the tank base. We characterize the geometry of the convective regime as well as its bulk thermal evolution by measuring the velocity field by Particle Image Velocimetry and the temperature field by using Thermochromic Liquid Crystals.

  9. An original approach to data acquisition CHADAC

    CERN Document Server

    CERN. Geneva

    1981-01-01

    Many labs try to boost existing data acquisition systems by inserting high performance intelligent devices in the important nodes of the system's structure. This strategy finds its limits in the system's architecture. The CHADAC project proposes a simple and efficient solution to this problem, using a multiprocessor modular architecture. CHADAC main features are: parallel acquisition of data; CHADAC is fast, it dedicates one processor per branch and each processor can read and store one 16 bit word in 800 ns; original structure; each processor can work in its own private memory, in its own shared memory (double access) and in the shared memory of any other processor. Simple and fast communications between processors are also provided by local DMAs; flexibility; each processor is autonomous and may be used as an independent acquisition system for a branch, by connecting local peripherals to it. Adjunction of fast trigger logic is possible. By its architecture and performances, CHADAC is designed to provide a g...

  10. Experimental industrial signal acquisition board in a large scientific device

    Science.gov (United States)

    Zeng, Xiangzhen; Ren, Bin

    2018-02-01

    In order to measure the industrial signal of neutrino experiment, a set of general-purpose industrial data acquisition board has been designed. It includes the function of switch signal input and output, and the function of analog signal input. The main components are signal isolation amplifier and filter circuit, ADC circuit, microcomputer systems and isolated communication interface circuit. Through the practical experiments, it shows that the system is flexible, reliable, convenient and economical, and the system has characters of high definition and strong anti-interference ability. Thus, the system fully meets the design requirements.

  11. An Efficient, Robust, and Inexpensive Grinding Device for Herbal Samples like Cinchona Bark.

    Science.gov (United States)

    Hansen, Steen Honoré; Holmfred, Else; Cornett, Claus; Maldonado, Carla; Rønsted, Nina

    2015-01-01

    An effective, robust, and inexpensive grinding device for the grinding of herb samples like bark and roots was developed by rebuilding a commercially available coffee grinder. The grinder was constructed to be able to provide various particle sizes, to be easy to clean, and to have a minimum of dead volume. The recovery of the sample when grinding as little as 50 mg of crude Cinchona bark was about 60%. Grinding is performed in seconds with no rise in temperature, and the grinder is easily disassembled to be cleaned. The influence of the particle size of the obtained powders on the recovery of analytes in extracts of Cinchona bark was investigated using HPLC.

  12. Impact of sampling interval in training data acquisition on intrafractional predictive accuracy of indirect dynamic tumor-tracking radiotherapy.

    Science.gov (United States)

    Mukumoto, Nobutaka; Nakamura, Mitsuhiro; Akimoto, Mami; Miyabe, Yuki; Yokota, Kenji; Matsuo, Yukinori; Mizowaki, Takashi; Hiraoka, Masahiro

    2017-08-01

    To explore the effect of sampling interval of training data acquisition on the intrafractional prediction error of surrogate signal-based dynamic tumor-tracking using a gimbal-mounted linac. Twenty pairs of respiratory motions were acquired from 20 patients (ten lung, five liver, and five pancreatic cancer patients) who underwent dynamic tumor-tracking with the Vero4DRT. First, respiratory motions were acquired as training data for an initial construction of the prediction model before the irradiation. Next, additional respiratory motions were acquired for an update of the prediction model due to the change of the respiratory pattern during the irradiation. The time elapsed prior to the second acquisition of the respiratory motion was 12.6 ± 3.1 min. A four-axis moving phantom reproduced patients' three dimensional (3D) target motions and one dimensional surrogate motions. To predict the future internal target motion from the external surrogate motion, prediction models were constructed by minimizing residual prediction errors for training data acquired at 80 and 320 ms sampling intervals for 20 s, and at 500, 1,000, and 2,000 ms sampling intervals for 60 s using orthogonal kV x-ray imaging systems. The accuracies of prediction models trained with various sampling intervals were estimated based on training data with each sampling interval during the training process. The intrafractional prediction errors for various prediction models were then calculated on intrafractional monitoring images taken for 30 s at the constant sampling interval of a 500 ms fairly to evaluate the prediction accuracy for the same motion pattern. In addition, the first respiratory motion was used for the training and the second respiratory motion was used for the evaluation of the intrafractional prediction errors for the changed respiratory motion to evaluate the robustness of the prediction models. The training error of the prediction model was 1.7 ± 0.7 mm in 3D for all sampling

  13. Data acquisition system for nuclear reactor environment

    International Nuclear Information System (INIS)

    Tiwari, Akash; Tiwari, Railesha; Tiwari, S.S.; Panday, Lokesh; Suri, Nitin; Chouksey, Abhsek; Singh, Sarvesh Kumar; Dwivedi, Tarun; Agrawal, Ashish; Pandey, Pranav Kumar; Sharma, Brijnandan; Bhatia, Chirag

    2004-01-01

    We have designed an online real time data acquisition system for nuclear reactor environment monitoring. Data acquisition system has eight channels of analog signals and one channel of pulsed input signal from detectors like GM Tube, or any other similar input. Connectivity between the data acquisition system and environmental parameters monitoring computer is made through a wireless data communication link of 151 MHz/100 mW RF power and 10 km maximum communication range for remote data telemetry. Sensors used are gamma ionizing radiation sensor made from CsI:Tl scintillator, atmospheric pressure sensor with +/-0.1 mbar precision, temperature sensor with +/-l milli degree Celsius precision, relative humidity with +/-0.1RH precision, pulse counts with +/-1 count in 0-10000 Hz count rate measurement precision and +/-1 count is accumulated count measurement precision. The entire data acquisition system and wireless telemetry system is 9 V battery powered and the device is to be fitted on a wireless controlled mobile robot for scanning the nuclear reactor zone from remote. Wireless video camera has been planned for integration into the existing system on a later date for moving the robotics environmental data acquisition system beyond human vision reach. System development cost is Rs.25 Lacs and has been developed for Department of Atomic Energy, Government of India and Indian Defense use. (author)

  14. Development of an automatic sampling device for the continuous measurement of atmospheric carbonyls compounds

    International Nuclear Information System (INIS)

    Perraud, V.

    2007-12-01

    Two sampling strategies were studied to develop an automatic instrument for the continuous measurement of atmospheric carbonyl compounds. Because of its specificity towards carbonyls compounds, sampling by using a transfer of gaseous phase in a liquid phase associated with a simultaneous chemical derivatization of the trapped compounds was first studied. However, this method do not allow a quantitative sampling of all studied carbonyl compounds, nor a continuous measurement in the field. To overcome the difficulties, a second strategy was investigated: the cryogenic adsorption onto solid adsorbent followed by thermodesorption and a direct analysis by GC/MS. Collection efficiency using different solid adsorbents was found greater than 95% for carbonyl compounds consisting of 1 to 7 carbons. This work is a successful first step towards the realization of the automatic sampling device for a continuous measurement of atmospheric carbonyls compounds. (author)

  15. Medical devices; exemption from premarket notification; Class II devices; optical impression systems for computer assisted design and manufacturing. Final rule.

    Science.gov (United States)

    2003-04-22

    The Food and Drug Administration (FDA) is publishing an order granting a petition requesting exemption from the premarket notification requirements for data acquisition units for ceramic dental restoration systems. This rule exempts from premarket notification data acquisition units for ceramic dental restoration systems and establishes a guidance document as a special control for this device. FDA is publishing this order in accordance with the Food and Drug Administration Modernization Act of 1997 (FDAMA).

  16. Effect of transient liquid flow on retention characteristics of screen acquisition systems. [design of Space Shuttle feed system

    Science.gov (United States)

    Cady, E. C.

    1977-01-01

    A design analysis, is developed based on experimental data, to predict the effects of transient flow and pressure surges (caused either by valve or pump operation, or by boiling of liquids in warm lines) on the retention performance of screen acquisition systems. A survey of screen liquid acquisition system applications was performed to determine appropriate system environment and classification. A screen model was developed which assumed that the screen device was a uniformly distributed composite orthotropic structure, and which accounted for liquid inflow/outflow, gas ingestion quality, screen stress, and liquid spill. A series of 177 tests using 13 specimens (5 screen meshes, 4 screen device construction/backup methods, and 2 orientations) with three test fluids (isopropyl alcohol, Freon 114, and LH2) provided data which verified important features of the screen model and resulted in a design tool which could accurately predict the transient startup performance acquisition devices.

  17. The acquisition of personal pronouns in cochlear-implanted children

    NARCIS (Netherlands)

    Verbist, Annemie Josee Jozef

    2010-01-01

    Today, many deaf children can be given access to oral language thanks to a cochlear implant, a surgically implanted electronic device that provides a sense of sound thanks to electric stimulation of the auditory nerve. In this study, the acquisition of personal pronouns is considered to be a measure

  18. Development and application of General Purpose Data Acquisition Shell (GPDAS) at advanced photon source

    International Nuclear Information System (INIS)

    Chung, Youngjoo; Kim, Keeman.

    1991-01-01

    An operating system shell GPDAS (General Purpose Data Acquisition Shell) on MS-DOS-based microcomputers has been developed to provide flexibility in data acquisition and device control for magnet measurements at the Advanced Photon Source. GPDAS is both a command interpreter and an integrated script-based programming environment. It also incorporates the MS-DOS shell to make use of the existing utility programs for file manipulation and data analysis. Features include: alias definition, virtual memory, windows, graphics, data and procedure backup, background operation, script programming language, and script level debugging. Data acquisition system devices can be controlled through IEEE488 board, multifunction I/O board, digital I/O board and Gespac crate via Euro G-64 bus. GPDAS is now being used for diagnostics R ampersand D and accelerator physics studies as well as for magnet measurements. Their hardware configurations will also be discussed. 3 refs., 3 figs

  19. Incorporating Ethical Consumption into Electronic Device Acquisition: A Proposal

    Science.gov (United States)

    Poggiali, Jennifer

    2016-01-01

    This essay proposes that librarians practice ethical consumption when purchasing electronic devices. Though librarians have long been engaged with environmentalism and social justice, few have suggested that such issues as e-waste and sweatshop labor should impact our decisions to acquire e-readers, tablets, and other electronics. This article…

  20. Sampling optimization for high-speed weigh-in-motion measurements using in-pavement strain-based sensors

    International Nuclear Information System (INIS)

    Zhang, Zhiming; Huang, Ying; Bridgelall, Raj; Palek, Leonard; Strommen, Robert

    2015-01-01

    Weigh-in-motion (WIM) measurement has been widely used for weight enforcement, pavement design, freight management, and intelligent transportation systems to monitor traffic in real-time. However, to use such sensors effectively, vehicles must exit the traffic stream and slow down to match their current capabilities. Hence, agencies need devices with higher vehicle passing speed capabilities to enable continuous weight measurements at mainline speeds. The current practices for data acquisition at such high speeds are fragmented. Deployment configurations and settings depend mainly on the experiences of operation engineers. To assure adequate data, most practitioners use very high frequency measurements that result in redundant samples, thereby diminishing the potential for real-time processing. The larger data memory requirements from higher sample rates also increase storage and processing costs. The field lacks a sampling design or standard to guide appropriate data acquisition of high-speed WIM measurements. This study develops the appropriate sample rate requirements as a function of the vehicle speed. Simulations and field experiments validate the methods developed. The results will serve as guidelines for future high-speed WIM measurements using in-pavement strain-based sensors. (paper)

  1. Sampling optimization for high-speed weigh-in-motion measurements using in-pavement strain-based sensors

    Science.gov (United States)

    Zhang, Zhiming; Huang, Ying; Bridgelall, Raj; Palek, Leonard; Strommen, Robert

    2015-06-01

    Weigh-in-motion (WIM) measurement has been widely used for weight enforcement, pavement design, freight management, and intelligent transportation systems to monitor traffic in real-time. However, to use such sensors effectively, vehicles must exit the traffic stream and slow down to match their current capabilities. Hence, agencies need devices with higher vehicle passing speed capabilities to enable continuous weight measurements at mainline speeds. The current practices for data acquisition at such high speeds are fragmented. Deployment configurations and settings depend mainly on the experiences of operation engineers. To assure adequate data, most practitioners use very high frequency measurements that result in redundant samples, thereby diminishing the potential for real-time processing. The larger data memory requirements from higher sample rates also increase storage and processing costs. The field lacks a sampling design or standard to guide appropriate data acquisition of high-speed WIM measurements. This study develops the appropriate sample rate requirements as a function of the vehicle speed. Simulations and field experiments validate the methods developed. The results will serve as guidelines for future high-speed WIM measurements using in-pavement strain-based sensors.

  2. Thermal probe design for Europa sample acquisition

    Science.gov (United States)

    Horne, Mera F.

    2018-01-01

    The planned lander missions to the surface of Europa will access samples from the subsurface of the ice in a search for signs of life. A small thermal drill (probe) is proposed to meet the sample requirement of the Science Definition Team's (SDT) report for the Europa mission. The probe is 2 cm in diameter and 16 cm in length and is designed to access the subsurface to 10 cm deep and to collect five ice samples of 7 cm3 each, approximately. The energy required to penetrate the top 10 cm of ice in a vacuum is 26 Wh, approximately, and to melt 7 cm3 of ice is 1.2 Wh, approximately. The requirement stated in the SDT report of collecting samples from five different sites can be accommodated with repeated use of the same thermal drill. For smaller sample sizes, a smaller probe of 1.0 cm in diameter with the same length of 16 cm could be utilized that would require approximately 6.4 Wh to penetrate the top 10 cm of ice, and 0.02 Wh to collect 0.1 g of sample. The thermal drill has the advantage of simplicity of design and operations and the ability to penetrate ice over a range of densities and hardness while maintaining sample integrity.

  3. Analysis of International Mergers and Acquisitions in the Pharmaceutical Industry

    Directory of Open Access Journals (Sweden)

    Božo Matić

    2011-07-01

    Full Text Available There are numerous researches which analyze mergers and acquisitions, but most of them do not focus on a certain industry, but their sample considers companies from different industries. This paper focuses on mergers and acquisitions in the pharmaceutical industry. It is assumed that pharmaceutical companies with no experience in mergers and acquisitions achieve better results in relatively small and domestic mergers and acquisitions while pharmaceutical companies with greater experience in mergers and acquisitions are successful even in bigger and international mergers and acquisitions. Bigger mergers and acquisitions and international mergers and acquisitions are more risky for the companies so lack of experience in mergers and acquisitions additionally increases risks during the process of mergers and acquisitions. On average, such increase of the risk results in lower returns for stock owners of pharmaceutical companies.

  4. Microbial profiling of cpn60 universal target sequences in artificial mixtures of vaginal bacteria sampled by nylon swabs or self-sampling devices under different storage conditions.

    Science.gov (United States)

    Schellenberg, John J; Oh, Angela Yena; Hill, Janet E

    2017-05-01

    The vaginal microbiome is increasingly characterized by deep sequencing of universal genes. However, there are relatively few studies of how different specimen collection and sample storage and processing influence these molecular profiles. Here, we evaluate molecular microbial community profiles of samples collected using the HerSwab™ self-sampling device, compared to nylon swabs and under different storage conditions. In order to minimize technical variation, mixtures of 11 common vaginal bacteria in simulated vaginal fluid medium were sampled and DNA extracts prepared for massively parallel sequencing of the cpn60 universal target (UT). Three artificial mixtures imitating commonly observed vaginal microbiome profiles were easily distinguished and proportion of sequence reads correlated with the estimated proportion of the organism added to the artificial mixtures. Our results indicate that cpn60 UT amplicon sequencing quantifies the proportional abundance of member organisms in these artificial communities regardless of swab type or storage conditions, although some significant differences were observed between samples that were stored frozen and thawed prior to DNA extraction, compared to extractions from samples stored at room temperature for up to 7days. Our results indicate that an on-the-market device developed for infectious disease diagnostics may be appropriate for vaginal microbiome profiling, an approach that is increasingly facilitated by rapidly dropping deep sequencing costs. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. French bank mergers and acquisitions performance

    Directory of Open Access Journals (Sweden)

    Houda Ben Said

    2017-11-01

    Full Text Available In this paper, we empirically investigate the impact of mergers and acquisitions on French bank performance. Performance is measured by potential gains in efficiency and value creation. We first analyzed efficiency using the data envelopment analysis (DEA under input oriented with variable returns to scale to obtain the efficiency scores. Second, we analyzed the impact on French bank value creation following mergers-acquisitions operations of a set of control variables (model 1 and explicative variables measuring strategic similarities between bidders and targets (model 2. The sample studied is composed of French bank mergers-acquisitions happening between 1996 and 2006 and implying one of the 14 greatest French banking groups. Empirical result showed that mergers and acquisitions have been traduced by an improvement in the overall efficiency by 17.82% and a shareholder value reduction by 5.14%

  6. Use of a dry-plasma collection device to overcome problems with storage and transportation of blood samples for epidemiology studies in developing countries.

    Science.gov (United States)

    Nurgalieva, Z Z; Almuchambetova, R; Machmudova, A; Kapsultanova, D; Osato, M S; Peacock, J; Zoltek, R P; Marchildon, P A; Graham, D Y; Zhangabylov, A

    2000-11-01

    Studies are difficult in areas lacking modern facilities due to the inability to reliably collect, store, and ship samples. Thus, we sought to evaluate the use of a dry plasma collection device for seroepidemiology studies. Plasma was obtained by fingerstick using a commercial dry plasma collection device (Chemcard Plasma Collection Device) and serum (venipuncture) from individuals in Kazakhstan. Plasma samples were air dried for 15 min and then stored desiccated in foil zip-lock pouches at 4 to 6 degrees C and subsequently shipped to the United States by air at ambient temperature. Serum samples remained frozen at -20 degrees C until assayed. Helicobacter pylori status was determined by enzyme-linked immunosorbent assay (HM-CAP EIA) for the dry plasma and the serum samples. The results were concordant in 250 of the 289 cases (86.5%). In 25 cases (8.6%), the dry plasma samples gave indeterminate results and could not be retested because only one sample was collected. Five serum samples were positive, and the corresponding dry plasma samples were negative; one serum sample was negative, and the corresponding plasma sample was positive. The relative sensitivity and specificity of the Chemcard samples to serum were 97.6 and 97.9%, respectively, excluding those with indeterminate results. Repeated freeze-thawing had no adverse effect on the accuracy of the test. We found the dry plasma collection device to provide an accurate and practical alternative to serum when venipuncture may be difficult or inconvenient and sample storage and handling present difficulties, especially for seroepidemiologic studies in rural areas or developing countries and where freeze-thawing may be unavoidable.

  7. Sampling device for in vivo sampling of liquids from the gastrointestinal tract, process for the production thereof and mould or mask for use in the production process

    NARCIS (Netherlands)

    Sprenkels, A.J.; Jenneboer, Antonius J.S.M.; Venema, Konraad; van den Berg, Albert; de Vos, Willem M.

    2006-01-01

    The present invention relates to a sampling device suitable for in vivo sampling of liquid(s) from the gastro-intestinal tract, comprising a body, the body comprising a channel and an opening for entrance of the liquid(s) at one end of the channel, and a cover bonded to at least part of the body and

  8. COLDEX New Data Acquisition Framework

    CERN Document Server

    Grech, Christian

    2015-01-01

    COLDEX (COLD bore EXperiment) is an experiment of the TE-VSC group installed in the Super Proton Synchrotron (SPS) which mimics a LHC type cryogenic vacuum system. In the framework of the High Luminosity upgrade of the LHC (HL-LHC project), COLDEX has been recommissioned in 2014 in order to validate carbon coatings performances at cryogenic temperature with LHC type beams. To achieve this mission, a data acquisition system is needed to retrieve and store information from the different experiment’s systems (vacuum, cryogenics, controls, safety) and perform specific calculations. This work aimed to completely redesign, implement, test and operate a brand new data acquisition framework based on communication with the experiment’s PLCs for the devices potentially available over network. The communication protocol to the PLCs is based on data retrieval both from CERN middleware infrastructures (CMW, JAPC) and on a novel open source Simatic S7 data exchange package over TCP/IP (libnodave).

  9. A higher level language data acquisition system (III) - the user data acquisition program

    International Nuclear Information System (INIS)

    Finn, J.M.; Gulbranson, R.L.; Huang, T.L.

    1983-01-01

    The nuclear physics group at the University of Illinois has implemented a data acquisition system using modified versions of the Concurrent Pascal and Sequential Pascal languages. The user, a physicist, develops a data acquisition ''operating system'', written in these higher level languages, which is tailored to the planned experiment. The user must include only those system functions which are essential to the task, thus improving efficiency. The user program is constructed from simple modules, mainly consisting of Concurrent Pascal PROCESSes, MONITORs, and CLASSes together with appropriate data type definitions. Entire programs can be put together using ''cut and paste'' techniques. Planned enhancements include the automating of this process. Systems written for the Perkin-Elmer 3220 using this approach can easily exceed 2 kHz data rates for event by event handling; 20 kHz data rates have been achieved by the addition of buffers in the interrupt handling software. These rates have been achieved without the use of special-purpose hardware such as micro-programmed branch drivers. With the addition of such devices even higher data rates should be possible

  10. Diagnostic-management system and test pulse acquisition for WEST plasma measurement system

    International Nuclear Information System (INIS)

    Wojenski, A.; Kasprowicz, G.; Pozniak, K.T.; Byszuk, A.; Juszczyk, B.; Zabolotny, W.; Zienkiewicz, P.; Chernyshova, M.; Czarski, T.; Mazon, D.; Malard, P.

    2014-01-01

    This paper describes current status of electronic, firmware and software development for new plasma measurement system for use in WEST facility. The system allows to perform two dimensional plasma visualization (in time) with spectrum measurement. The analog front-end is connected to Gas Electron Multiplier detector (GEM detector). The system architecture have high data throughput due to use of PCI-Express interface, Gigabit Transceivers and sampling frequency of ADC integrated circuits. The hardware is based on several years of experience in building X-ray spectrometer system for Joint European Torus (JET) facility. Data streaming is done using Artix7 FPGA devices. The system in basic configuration can work with up to 256 channels, while the maximum number of measurement channels is 2048. Advanced firmware for the FPGA is required in order to perform high speed data streaming and analog signal sampling. Diagnostic system management has been developed in order to configure measurement system, perform necessary calibration and prepare hardware for data acquisition. (authors)

  11. Reflector automatic acquisition and pointing based on auto-collimation theodolite

    Science.gov (United States)

    Luo, Jun; Wang, Zhiqian; Wen, Zhuoman; Li, Mingzhu; Liu, Shaojin; Shen, Chengwu

    2018-01-01

    An auto-collimation theodolite (ACT) for reflector automatic acquisition and pointing is designed based on the principle of autocollimators and theodolites. First, the principle of auto-collimation and theodolites is reviewed, and then the coaxial ACT structure is developed. Subsequently, the acquisition and pointing strategies for reflector measurements are presented, which first quickly acquires the target over a wide range and then points the laser spot to the charge coupled device zero position. Finally, experiments are conducted to verify the acquisition and pointing performance, including the calibration of the ACT, the comparison of the acquisition mode and pointing mode, and the accuracy measurement in horizontal and vertical directions. In both directions, a measurement accuracy of ±3″ is achieved. The presented ACT is suitable for automatic pointing and monitoring the reflector over a small scanning area and can be used in a wide range of applications such as bridge structure monitoring and cooperative target aiming.

  12. Development of ''SonialvisionSafireII'' system with a new digital radiography device

    International Nuclear Information System (INIS)

    Sano, Takayuki; Okumura, Takeshi; Sakai, Takihito; Fujiwara, Masashi; Toyoda, Toshihide

    2007-01-01

    We released the world's first X-TV system equipped with a 17 inch direct conversion type flat panel X-ray detector (FPD) ''Safire'' in an radiofrequency (RF) table in 2004. Our latest X-TV system, called SonialvisionSafireII, incorporates the digital radiography device and the high voltage generator both of which were newly developed to take better advantage of the characteristics of the FPD. The following are the features of the latest system: Image acquisition and processing with the original matrix of FPD (up to 2880 x 2880 matrix with a 17-inch field of view (FOV)), High-speed radiography in serial acquisition mode (up to 15 fps) and tomosynthesis acquisition mode (up to 30 fps), Operationally improved digital radiography device using a general-purpose personal computer. (author)

  13. Biomedical signal acquisition, processing and transmission using smartphone

    International Nuclear Information System (INIS)

    Roncagliolo, Pablo; Arredondo, Luis; Gonzalez, AgustIn

    2007-01-01

    This article describes technical aspects involved in the programming of a system of acquisition, processing and transmission of biomedical signals by using mobile devices. This task is aligned with the permanent development of new technologies for the diagnosis and sickness treatment, based on the feasibility of measuring continuously different variables as electrocardiographic signals, blood pressure, oxygen concentration, pulse or simply temperature. The contribution of this technology is settled on its portability and low cost, which allows its massive use. Specifically this work analyzes the feasibility of acquisition and the processing of signals from a standard smartphone. Work results allow to state that nowadays these equipments have enough processing capacity to execute signals acquisition systems. These systems along with external servers make it possible to imagine a near future where the possibility of making continuous measures of biomedical variables will not be restricted only to hospitals but will also begin to be more frequently used in the daily life and at home

  14. Biomedical signal acquisition, processing and transmission using smartphone

    Energy Technology Data Exchange (ETDEWEB)

    Roncagliolo, Pablo [Department of Electronics, Universidad Tecnica Federico Santa Maria, Casilla 110-V, ValparaIso (Chile); Arredondo, Luis [Department of Biomedical Engineering, Universidad de ValparaIso, Casilla 123-V, ValparaIso (Chile); Gonzalez, AgustIn [Department of Electronics, Universidad Tecnica Federico Santa MarIa, Casilla 110-V, ValparaIso (Chile)

    2007-11-15

    This article describes technical aspects involved in the programming of a system of acquisition, processing and transmission of biomedical signals by using mobile devices. This task is aligned with the permanent development of new technologies for the diagnosis and sickness treatment, based on the feasibility of measuring continuously different variables as electrocardiographic signals, blood pressure, oxygen concentration, pulse or simply temperature. The contribution of this technology is settled on its portability and low cost, which allows its massive use. Specifically this work analyzes the feasibility of acquisition and the processing of signals from a standard smartphone. Work results allow to state that nowadays these equipments have enough processing capacity to execute signals acquisition systems. These systems along with external servers make it possible to imagine a near future where the possibility of making continuous measures of biomedical variables will not be restricted only to hospitals but will also begin to be more frequently used in the daily life and at home.

  15. Biomedical signal acquisition, processing and transmission using smartphone

    Science.gov (United States)

    Roncagliolo, Pablo; Arredondo, Luis; González, Agustín

    2007-11-01

    This article describes technical aspects involved in the programming of a system of acquisition, processing and transmission of biomedical signals by using mobile devices. This task is aligned with the permanent development of new technologies for the diagnosis and sickness treatment, based on the feasibility of measuring continuously different variables as electrocardiographic signals, blood pressure, oxygen concentration, pulse or simply temperature. The contribution of this technology is settled on its portability and low cost, which allows its massive use. Specifically this work analyzes the feasibility of acquisition and the processing of signals from a standard smartphone. Work results allow to state that nowadays these equipments have enough processing capacity to execute signals acquisition systems. These systems along with external servers make it possible to imagine a near future where the possibility of making continuous measures of biomedical variables will not be restricted only to hospitals but will also begin to be more frequently used in the daily life and at home.

  16. Occurrence of contaminants of emerging concern along the California coast (2009-10) using passive sampling devices

    Science.gov (United States)

    Alvarez, David A.; Maruya, Keith A.; Dodder, Nathan G.; Lao, Wenjian; Furlong, Edward T.; Smalling, Kelly L.

    2014-01-01

    Three passive sampling devices (PSDs), polar organic chemical integrative samplers (POCIS), polyethylene devices (PEDs), and solid-phase microextraction (SPME) samplers were used to sample a diverse set of chemicals in the coastal waters of San Francisco Bay and the Southern California Bight. Seventy one chemicals (including fragrances, phosphate flame retardants, pharmaceuticals, PAHs, PCBs, PBDEs, and pesticides) were measured in at least 50% of the sites. The chemical profile from the San Francisco Bay sites was distinct from profiles from the sites in the Southern California Bight. This distinction was not due to a single compound or class, but by the relative abundances/concentrations of the chemicals. Comparing the PSDs to mussel (Mytilus spp.) tissues, a positive correlation exists for the 25 and 26 chemicals in common for the PEDs and SPME, respectively. Diphenhydramine was the only common chemical out of 40 analyzed in both POCIS and tissues detected at a common site.

  17. A simple timestamping data acquisition system for ToF-ERDA

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Mikko, E-mail: mikrossi@jyu.fi; Rahkila, Panu; Kettunen, Heikki; Laitinen, Mikko

    2015-03-15

    A new data acquisition system, ToF-DAQ, has been developed for a ToF-ERDA telescope and other ToF-E and ToF–ToF measurement systems. ToF-DAQ combines an analogue electronics front-end to asynchronous time stamped data acquisition by means of a FPGA device. Coincidences are sought solely in software based on the timestamps. Timestamping offers more options for data analysis as coincidence events can be built also in offline analysis. The system utilizes a National Instruments R-series FPGA device and a Windows PC as a host computer. Both the FPGA code and the host software were developed using the National Instruments LabVIEW graphical programming environment. Up to eight NIM ADCs can be handled by a single FPGA. The host computer and the FPGA can process total continuous count rates of over 750,000 counts/s with a timestamping resolution of 8.33 ns.

  18. Electronic system for data acquisition to study radiation effects on operating MOSFET transistors

    International Nuclear Information System (INIS)

    Alves de Oliveira, Juliano; Assis de Melo, Marco Antônio; Guazzelli da Silveira, Marcilei A.; Medina, Nilberto H.

    2014-01-01

    In this work we present the development of an acquisition system for characterizing transistors under X-ray radiation. The system is able to carry out the acquisition and to storage characteristic transistor curves. To test the acquisition system we have submitted polarized P channel MOS transistors under continuous 10-keV X-ray doses up to 1500 krad. The characterization system can operate in the saturation region or in the linear region in order to observe the behavior of the currents or voltages involved during the irradiation process. Initial tests consisted of placing the device under test (DUT) in front of the X-ray beam direction, while its drain current was constantly monitored through the prototype generated in this work, the data are stored continuously and system behavior was monitored during the test. In order to observe the behavior of the DUT during the radiation tests, we used an acquisition system that consists of an ultra-low consumption16-bit Texas Instruments MSP430 microprocessor. Preliminary results indicate linear behavior of the voltage as a function of the exposure time and fast recovery. These features may be favorable to use this device as a radiation dosimeter to monitor low rate X-ray

  19. Distributed multiprotocol acquisition network for environmental data

    Science.gov (United States)

    Barone, Fabrizio; De Rosa, Rosario; Milano, Leopoldo; Qipiani, Ketevan

    2003-03-01

    The acquisition and storage of large amount of data coming from distributed environmental sensors of different kind can be solved with the aid of a network between the acquisition subsystems, but problems can arise if they are not homogeneous. In this case the network should be as flexible as possible to ensure modularity and connectivity. In this work we describe the development and testing of a network based acquisition system. The network uses, where possible, commercial products, based on different standards, in order to increase the availability of its components, as well as its modularity. In addition it is completely independent from proprietary hardware and software products. In particular we tested an acquisition network based on multiple transmission protocol, like wireless and cabled RS232 and Fast Ethernet, which includes the acquisition, archiving and data analysis systems. Each acquisition subsystem can get time from satellite using GPS, and is able to monitor seismic activity, temperature, pressure, humidity and electromagnetic data. The sampling frequency and the dynamics of the acquired data can be matched to the characteristics of each probe. All the acquisition stations can use different platform as well as different operating systems. Tests have been performed to evaluate the capability of long acquisition periods and the fault tolerance of the whole system.

  20. Microwave heating device for internal heating convection experiments, applied to Earth's mantle dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Surducan, E.; Surducan, V.; Neamtu, C., E-mail: camelia.neamtu@itim-cj.ro [National Institute for Research and Development of Isotopic and Molecular Technologies (INCDTIM), 67-103 Donat St., 400293, Cluj‑Napoca (Romania); Limare, A.; Di Giuseppe, E. [Institut de Physique du Globe de Paris (IPGP), Univ. Paris Diderot, UMR CNRS 7154, 1 rue Jussieu, 75005, Paris (France)

    2014-12-15

    We report the design, construction, and performances of a microwave (MW) heating device for laboratory experiments with non-contact, homogeneous internal heating. The device generates MW radiation at 2.47 GHz from a commercial magnetron supplied by a pulsed current inverter using proprietary, feedback based command and control hardware and software. Specially designed MW launchers direct the MW radiation into the sample through a MW homogenizer, devised to even the MW power distribution into the sample's volume. An adjustable MW circuit adapts the MW generator to the load (i.e., the sample) placed in the experiment chamber. Dedicated heatsinks maintain the MW circuits at constant temperature throughout the experiment. Openings for laser scanning for image acquisition with a CCD camera and for the cooling circuits are protected by special MW filters. The performances of the device are analyzed in terms of heating uniformity, long term output power stability, and load matching. The device is used for small scale experiments simulating Earth's mantle convection. The 30 × 30 × 5 cm{sup 3} convection tank is filled with a water‑based viscous fluid. A uniform and constant temperature is maintained at the upper boundary by an aluminum heat exchanger and adiabatic conditions apply at the tank base. We characterize the geometry of the convective regime as well as its bulk thermal evolution by measuring the velocity field by Particle Image Velocimetry and the temperature field by using Thermochromic Liquid Crystals.

  1. On Shaft Data Acquisition System (OSDAS)

    Science.gov (United States)

    Pedings, Marc; DeHart, Shawn; Formby, Jason; Naumann, Charles

    2012-01-01

    On Shaft Data Acquisition System (OSDAS) is a rugged, compact, multiple-channel data acquisition computer system that is designed to record data from instrumentation while operating under extreme rotational centrifugal or gravitational acceleration forces. This system, which was developed for the Heritage Fuel Air Turbine Test (HFATT) program, addresses the problem of recording multiple channels of high-sample-rate data on most any rotating test article by mounting the entire acquisition computer onboard with the turbine test article. With the limited availability of slip ring wires for power and communication, OSDAS utilizes its own resources to provide independent power and amplification for each instrument. Since OSDAS utilizes standard PC technology as well as shared code interfaces with the next-generation, real-time health monitoring system (SPARTAA Scalable Parallel Architecture for Real Time Analysis and Acquisition), this system could be expanded beyond its current capabilities, such as providing advanced health monitoring capabilities for the test article. High-conductor-count slip rings are expensive to purchase and maintain, yet only provide a limited number of conductors for routing instrumentation off the article and to a stationary data acquisition system. In addition to being limited to a small number of instruments, slip rings are prone to wear quickly, and introduce noise and other undesirable characteristics to the signal data. This led to the development of a system capable of recording high-density instrumentation, at high sample rates, on the test article itself, all while under extreme rotational stress. OSDAS is a fully functional PC-based system with 48 channels of 24-bit, high-sample-rate input channels, phase synchronized, with an onboard storage capacity of over 1/2-terabyte of solid-state storage. This recording system takes a novel approach to the problem of recording multiple channels of instrumentation, integrated with the test

  2. Moessbauer spectrometric data acquisition based on FPGA

    International Nuclear Information System (INIS)

    Zhang Yuan; Li Shimin; Chen Nan; Zhu Jingbo; Xia Yuanfu

    2008-01-01

    FPGA(Field Programmable Gate Array) is a programmable device with strong logical function and timing control ability. It is extremely potent in acquiring and processing timing signals. By replacing the traditional used SCM (Single-Chip Microcomputer) with FPGA, counting speed of Moessbauer spectrometric data acquisition can be improved markedly with significantly decreased size of the spectrometer. The counter, RAM and RS-232 communication of the module are developed on Altera Cyclone series chip EP1C6T144C8 with Quartus II. EP1C6T144C8 has 5980 logical units accompanied by 92160 bits of memory space. It is so powerful that all needs in data acquisition of the Moessbauer spectrometer can be perfectly satisfied while allowing modifications in functions and parameters. (authors)

  3. KENS data acquisition system KENSnet

    International Nuclear Information System (INIS)

    Arai, Masatoshi; Furusaka, Michihiro; Satoh, Setsuo; Johnson, M.W.

    1988-01-01

    The installation of a new data acquisition system KENSnet has been completed at the KENS neutron facility. For data collection, 160 Mbytes are necessary for temporary disk storage, and 1 MIPS of CPU is required. For the computing system, models were chosen from the VAX family of computers running their proprietary operating system VMS. The VMS operating system has a very user friendly interface, and is well suited to instrument control applications. New data acquisition electronics were developed. A gate module receives a signal of proton extraction time from the accelerator, and checks the veto signals from the sample environment equipment (vacuum, temperature, chopper phasing, etc.). Then the signal is issued to a delay-time module. A time-control module starts timing from the delayed start signal from the delay-time module, and distributes an encoded time-boundary address to memory modules at the preset times anabling the memory modules to accumulate data histograms. The data acquisition control program (ICP) and the general data analysis program (Genie) were both developed at ISIS, and have been installed in the new data acquisition system. They give the experimenter 'user-friendly' data acquisition and a good environment for data manipulation. The ICP controls the DAE and transfers the histogram data into the computers. (N.K.)

  4. Virtual instrumentation on mobile devices for deployment in nuclear installations

    International Nuclear Information System (INIS)

    Farias, Marcos Santana; Santos, Isaac Jose A. Luquetti dos; Jesus, Miller F. de; Sant'Anna, Claudio Reis de; Szabo, Andre Pedro; Carvalho, Paulo Victor R. de

    2013-01-01

    The virtual instrumentation can be defined as a layer of software and hardware, added to a general purpose computer, so that users can interact with the computer in the same way that they interacted with traditional electronic instruments such as oscilloscopes, multi-meters and signal generators, and may add other functions defined by software. The virtual instrumentation gets a new integration environment, little explored yet, with the great growth that occurred in the mobile devices area. Nowadays it is possible to take measurements in more places by combining mobile devices with data acquisition hardware to create extremely portable and interconnected measurement systems. This paper shows the development of software and hardware that make possible the use of instrumentation on mobile devices for monitoring nuclear installations. It's presented the hardware and the application software for data acquisition of radiation monitors, developed to iOS devices. It's also shown the possibilities of hardware and software to develop near real-time data transfer to and from the field in nuclear installations, with benefits in efficiency, safety and productivity. (author)

  5. On the use of ultracentrifugal devices for routine sample preparation in biomolecular magic-angle-spinning NMR.

    Science.gov (United States)

    Mandal, Abhishek; Boatz, Jennifer C; Wheeler, Travis B; van der Wel, Patrick C A

    2017-03-01

    A number of recent advances in the field of magic-angle-spinning (MAS) solid-state NMR have enabled its application to a range of biological systems of ever increasing complexity. To retain biological relevance, these samples are increasingly studied in a hydrated state. At the same time, experimental feasibility requires the sample preparation process to attain a high sample concentration within the final MAS rotor. We discuss these considerations, and how they have led to a number of different approaches to MAS NMR sample preparation. We describe our experience of how custom-made (or commercially available) ultracentrifugal devices can facilitate a simple, fast and reliable sample preparation process. A number of groups have since adopted such tools, in some cases to prepare samples for sedimentation-style MAS NMR experiments. Here we argue for a more widespread adoption of their use for routine MAS NMR sample preparation.

  6. On the use of ultracentrifugal devices for routine sample preparation in biomolecular magic-angle-spinning NMR

    Energy Technology Data Exchange (ETDEWEB)

    Mandal, Abhishek; Boatz, Jennifer C. [University of Pittsburgh School of Medicine, Department of Structural Biology (United States); Wheeler, Travis B. [University of Pittsburgh School of Medicine, Department of Cell Biology (United States); Wel, Patrick C. A. van der, E-mail: vanderwel@pitt.edu [University of Pittsburgh School of Medicine, Department of Structural Biology (United States)

    2017-03-15

    A number of recent advances in the field of magic-angle-spinning (MAS) solid-state NMR have enabled its application to a range of biological systems of ever increasing complexity. To retain biological relevance, these samples are increasingly studied in a hydrated state. At the same time, experimental feasibility requires the sample preparation process to attain a high sample concentration within the final MAS rotor. We discuss these considerations, and how they have led to a number of different approaches to MAS NMR sample preparation. We describe our experience of how custom-made (or commercially available) ultracentrifugal devices can facilitate a simple, fast and reliable sample preparation process. A number of groups have since adopted such tools, in some cases to prepare samples for sedimentation-style MAS NMR experiments. Here we argue for a more widespread adoption of their use for routine MAS NMR sample preparation.

  7. Data acquisition system for linear PSD based neutron diffractometer

    International Nuclear Information System (INIS)

    Pande, S.S.; Borkar, S.P.; Behere, Anita; Ghodgaonkar, M.D.

    2001-01-01

    Single or multi-PSD configurations are used in different neutron diffractometer setups. A data acquisition system is developed to serve the gross requirements of all the diffractometer setups. It is also customized to specific requirements of different setups. The hardware is developed as a Transputer based add-on card. Most of the hardware functionality is handled in the Transputer program thus improving throughput of the system. The card can handle 16 RDCs, a few motor controls and on/off controls. The software comprises of a front-end Windows98 application, a Transputer program and a device driver. The data acquisition system performs data acquisition, analysis, display and storage. Analysis includes converting raw data of linear PSD to equiangular format, merging and clubbing the data to make a continuous equiangular spectrum. Calibration of individual PSD is a crucial activity in correctly merging the data coming from PSDs. (author)

  8. Data acquisition and processing software for linear PSD based neutron diffractometers

    International Nuclear Information System (INIS)

    Pande, S.S.; Borkar, S.P.; Ghodgaonkar, M.D.

    2003-01-01

    As a part of data acquisition system for various single and multi-PSD diffractometers software is developed to acquire the data and support the requirements of diffraction experiments. The software is a front-end Windows 98 application on PC and a transputer program on the MPSD card. The front-end application provides entire user interface required for data acquisition, control, presentation and system setup. Data is acquired and the diffraction spectra are generated in the transputer program. All the required hardware control is also implemented in the transputer program. The two programs communicate using a device driver named VTRANSPD. The software plays a vital role in customizing and integrating the data acquisition system for various diffractometer setups. Also the experiments are effectively automated in the software which has helped in making best use of available beam time. These and other features of the data acquisition and processing software are presented here. This software is being used along with the data acquisition system at a few single PSD and multi-PSD diffractometers. (author)

  9. Research on Multichannel Test Device of Missile Fuze

    Directory of Open Access Journals (Sweden)

    Guoyong Zhen

    2014-05-01

    Full Text Available This paper introduces the design of multichannel acquisition circuit based on FPGA which samples and records the Doppler signals, ignition signal and the working condition of fuze security enforcement agencies of missile fuze in real-time in the test of high speed dynamic intersection. Furthermore, for the problem of increasing number of sample channel which causes the complexity of the multiplexer control, a general programmable channel switching method is proposed based on FPGA. In the method, FPGA is the control core, and using the internal ROM resource effectively simplifies the complexity of channel switch in the multichannel acquisition system. This paper analyzes the acquisition system design, and describes the design of hardware circuit and analog switch address coding in detail. The test result shows that the acquisition circuit meets the design requirements with high sampling precision and application value.

  10. Construction and calibration of a low cost and fully automated vibrating sample magnetometer

    International Nuclear Information System (INIS)

    El-Alaily, T.M.; El-Nimr, M.K.; Saafan, S.A.; Kamel, M.M.; Meaz, T.M.; Assar, S.T.

    2015-01-01

    A low cost vibrating sample magnetometer (VSM) has been constructed by using an electromagnet and an audio loud speaker; where both are controlled by a data acquisition device. The constructed VSM records the magnetic hysteresis loop up to 8.3 KG at room temperature. The apparatus has been calibrated and tested by using magnetic hysteresis data of some ferrite samples measured by two scientifically calibrated magnetometers; model (Lake Shore 7410) and model (LDJ Electronics Inc. Troy, MI). Our VSM lab-built new design proved success and reliability. - Highlights: • A low cost automated vibrating sample magnetometer VSM has been constructed. • The VSM records the magnetic hysteresis loop up to 8.3 KG at room temperature. • The VSM has been calibrated and tested by using some measured ferrite samples. • Our VSM lab-built new design proved success and reliability

  11. Construction and calibration of a low cost and fully automated vibrating sample magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    El-Alaily, T.M., E-mail: toson_alaily@yahoo.com [Physics Department, Faculty of Science, Tanta University, Tanta (Egypt); El-Nimr, M.K.; Saafan, S.A.; Kamel, M.M.; Meaz, T.M. [Physics Department, Faculty of Science, Tanta University, Tanta (Egypt); Assar, S.T. [Engineering Physics and Mathematics Department, Faculty of Engineering, Tanta University, Tanta (Egypt)

    2015-07-15

    A low cost vibrating sample magnetometer (VSM) has been constructed by using an electromagnet and an audio loud speaker; where both are controlled by a data acquisition device. The constructed VSM records the magnetic hysteresis loop up to 8.3 KG at room temperature. The apparatus has been calibrated and tested by using magnetic hysteresis data of some ferrite samples measured by two scientifically calibrated magnetometers; model (Lake Shore 7410) and model (LDJ Electronics Inc. Troy, MI). Our VSM lab-built new design proved success and reliability. - Highlights: • A low cost automated vibrating sample magnetometer VSM has been constructed. • The VSM records the magnetic hysteresis loop up to 8.3 KG at room temperature. • The VSM has been calibrated and tested by using some measured ferrite samples. • Our VSM lab-built new design proved success and reliability.

  12. Autonomous acquisition systems for TJ-II: controlling instrumentation with a fourth generation language

    International Nuclear Information System (INIS)

    Sanchez, E.; Portas, A.B.; Vega, J.; Agudo, J.M.; McCarthy, K.J.; Ruiz, M.; Barrera, E.; Lopez, S.

    2004-01-01

    Recently, 536 new acquisition channels, made-up of three different channel types, have been incorporated into the TJ-II data acquisition system (DAQ). Dedicated software has also been developed to permit experimentalists to program and control the data acquisition in these systems. The software has been developed using LabView and runs under the Windows 2000 operating system in both personal computer (PC) and PXI controllers. In addition, LabView software has been developed to control TJ-II VXI channels from a PC using a MXI connection. This new software environment will also aid future integration of acquisition channels into the TJ-II remote participation system. All of these acquisition devices work autonomously and are connected to the TJ-II central server via a local area network. In addition, they can be remotely controlled from the TJ-II control-room using Virtual Network Computing (VNC) software

  13. Residual Network Data Structures in Android Devices

    Science.gov (United States)

    2011-09-01

    particular cellular tower that can be physically geolocated . Wireless routers, commonly found in businesses and homes share their unique Media Access...commercial acquisition tool. The method was compiled with standard Symbian APIs to access the file system and only tested on Symbian mobile devices [20

  14. Data acquisition system from uncorrelated experimental inputs

    International Nuclear Information System (INIS)

    Bals, I.; Caprini, M.; Goran, B.; Lutescu, S.; Niculescu, D.

    1974-01-01

    The system described in this work was performed as a small acquisition center for neutron physics experiment and was designed as a specialized device. The system was entirely MSI and SSI integrated circuits performed using 33 double sided printed circuit boards. The modular structure with information flow on buses led to wining simplification. The system can be further developed, using appropriate interfaces and programming modules to extend the range of possible experiments

  15. Modular data acquisition system and its use in gas-filled detector readout at ESRF

    Science.gov (United States)

    Sever, F.; Epaud, F.; Poncet, F.; Grave, M.; Rey-Bakaikoa, V.

    1996-09-01

    Since 1992, 18 ESRF beamlines are open to users. Although the data acquisition requirements vary a lot from one beamline to another, we are trying to implement a modular data acquisition system architecture that would fit with the maximum number of acquisition projects at ESRF. Common to all of these systems are large acquisition memories and the requirement to visualize the data during an acquisition run and to transfer them quickly after the run to safe storage. We developed a general memory API handling the acquisition memory and its organization and another library that provides calls for transferring the data over TCP/IP sockets. Interesting utility programs using these libraries are the `online display' program and the `data transfer' program. The data transfer program as well as an acquisition control program rely on our well-established `device server model', which was originally designed for the machine control system and then successfully reused in beamline control systems. In the second half of this paper, the acquisition system for a 2D gas-filled detector is presented, which is one of the first concrete examples using the proposed modular data acquisition architecture.

  16. Control, data acquisition and remote participation for steady-state operation in LHD

    International Nuclear Information System (INIS)

    Sudo, S.; Nagayama, Y.; Emoto, M.; Nakanishi, H.; Chikaraishi, H.; Imazu, S.; Iwata, C.; Kogi, Y.; Kojima, M.; Komada, S.; Kubo, S.; Kumazawa, R.; Mase, A.; Miyazawa, J.; Mutoh, T.; Nakamura, Y.; Nonomura, M.; Ohsuna, M.; Saito, K.; Sakamoto, R.; Seki, T.; Shoji, M.; Tsuda, K.; Yoshida, M.

    2006-01-01

    Control, data acquisition, plasma monitoring and remote participation for steady state operation in the large helical device (LHD) are reviewed. By controlling the impedance matching of ICH, the plasma position and the electron density, high temperature plasma is confined for 1905s. The plasma parameters are monitored in real time. Data are continuously sampled by the YOKOGAWA WE7000 system and by the NATIONAL INSTRUMENTS CompactPCI system. Those data are managed by the object-oriented database system based on ObjectStore in distributed servers with mass storage. By using the multi protocol label switching-virtual private network (MPLS-VPN) technology, the local area network of LHD is expanded to the Japanese fusion community. This provides the remote participants with the same environment of the LHD control room

  17. Control, data acquisition and remote participation for steady-state operation in LHD

    Energy Technology Data Exchange (ETDEWEB)

    Sudo, S. [National Institute of Natural Sciences, 322-6 Oroshi, Toki 509-5292 (Japan)]. E-mail: sudo@nifs.ac.jp; Nagayama, Y. [National Institute of Natural Sciences, 322-6 Oroshi, Toki 509-5292 (Japan); Emoto, M. [National Institute of Natural Sciences, 322-6 Oroshi, Toki 509-5292 (Japan); Nakanishi, H. [National Institute of Natural Sciences, 322-6 Oroshi, Toki 509-5292 (Japan); Chikaraishi, H. [National Institute of Natural Sciences, 322-6 Oroshi, Toki 509-5292 (Japan); Imazu, S. [National Institute of Natural Sciences, 322-6 Oroshi, Toki 509-5292 (Japan); Iwata, C. [National Institute of Natural Sciences, 322-6 Oroshi, Toki 509-5292 (Japan); Kogi, Y. [KASTEC, Kyushu University, Kasuga 816-8580 (Japan); Kojima, M. [National Institute of Natural Sciences, 322-6 Oroshi, Toki 509-5292 (Japan); Komada, S. [National Institute of Natural Sciences, 322-6 Oroshi, Toki 509-5292 (Japan); Kubo, S. [National Institute of Natural Sciences, 322-6 Oroshi, Toki 509-5292 (Japan); Kumazawa, R. [National Institute of Natural Sciences, 322-6 Oroshi, Toki 509-5292 (Japan); Mase, A. [KASTEC, Kyushu University, Kasuga 816-8580 (Japan); Miyazawa, J. [National Institute of Natural Sciences, 322-6 Oroshi, Toki 509-5292 (Japan); Mutoh, T. [National Institute of Natural Sciences, 322-6 Oroshi, Toki 509-5292 (Japan); Nakamura, Y. [National Institute of Natural Sciences, 322-6 Oroshi, Toki 509-5292 (Japan); Nonomura, M. [National Institute of Natural Sciences, 322-6 Oroshi, Toki 509-5292 (Japan); Ohsuna, M. [National Institute of Natural Sciences, 322-6 Oroshi, Toki 509-5292 (Japan); Saito, K. [National Institute of Natural Sciences, 322-6 Oroshi, Toki 509-5292 (Japan); Sakamoto, R.; Seki, T.; Shoji, M.; Tsuda, K.; Yoshida, M. [National Institute of Natural Sciences, 322-6 Oroshi, Toki 509-5292 (Japan)

    2006-07-15

    Control, data acquisition, plasma monitoring and remote participation for steady state operation in the large helical device (LHD) are reviewed. By controlling the impedance matching of ICH, the plasma position and the electron density, high temperature plasma is confined for 1905s. The plasma parameters are monitored in real time. Data are continuously sampled by the YOKOGAWA WE7000 system and by the NATIONAL INSTRUMENTS CompactPCI system. Those data are managed by the object-oriented database system based on ObjectStore in distributed servers with mass storage. By using the multi protocol label switching-virtual private network (MPLS-VPN) technology, the local area network of LHD is expanded to the Japanese fusion community. This provides the remote participants with the same environment of the LHD control room.

  18. A user configurable data acquisition and signal processing system for high-rate, high channel count applications

    International Nuclear Information System (INIS)

    Salim, Arwa; Crockett, Louise; McLean, John; Milne, Peter

    2012-01-01

    Highlights: ► The development of a new digital signal processing platform is described. ► The system will allow users to configure the real-time signal processing through software routines. ► The architecture of the DRUID system and signal processing elements is described. ► A prototype of the DRUID system has been developed for the digital chopper-integrator. ► The results of acquisition on 96 channels at 500 kSamples/s per channel are presented. - Abstract: Real-time signal processing in plasma fusion experiments is required for control and for data reduction as plasma pulse times grow longer. The development time and cost for these high-rate, multichannel signal processing systems can be significant. This paper proposes a new digital signal processing (DSP) platform for the data acquisition system that will allow users to easily customize real-time signal processing systems to meet their individual requirements. The D-TACQ reconfigurable user in-line DSP (DRUID) system carries out the signal processing tasks in hardware co-processors (CPs) implemented in an FPGA, with an embedded microprocessor (μP) for control. In the fully developed platform, users will be able to choose co-processors from a library and configure programmable parameters through the μP to meet their requirements. The DRUID system is implemented on a Spartan 6 FPGA, on the new rear transition module (RTM-T), a field upgrade to existing D-TACQ digitizers. As proof of concept, a multiply-accumulate (MAC) co-processor has been developed, which can be configured as a digital chopper-integrator for long pulse magnetic fusion devices. The DRUID platform allows users to set options for the integrator, such as the number of masking samples. Results from the digital integrator are presented for a data acquisition system with 96 channels simultaneously acquiring data at 500 kSamples/s per channel.

  19. Basic simulation models of phase tracking devices using Matlab

    CERN Document Server

    Tranter, William

    2010-01-01

    The Phase-Locked Loop (PLL), and many of the devices used for frequency and phase tracking, carrier and symbol synchronization, demodulation, and frequency synthesis, are fundamental building blocks in today's complex communications systems. It is therefore essential for both students and practicing communications engineers interested in the design and implementation of modern communication systems to understand and have insight into the behavior of these important and ubiquitous devices. Since the PLL behaves as a nonlinear device (at least during acquisition), computer simulation can be used

  20. 128 Channel PCI-based data acquisition system for MDSplus

    Energy Technology Data Exchange (ETDEWEB)

    Llobet, Xavier E-mail: xavier.llobet@epfl.ch; Duval, Basil P. E-mail: basil.duval@epfl.ch

    2002-06-01

    With the increasing demand for analogue channel acquisition on the TCV tokamak, a new PCI based acquisition has been specified, designed, built and installed into our MDSplus acquisition environment. The design criteria were to not only improve the cost/channel, as compared to our conventional hub based acquisition (CAMAC), but to provide some distributed processing power to avoid the associated acquisition server saturation, both in terms of CPU and network bandwidth. These units were initially intended to satisfy the requirements of general variable rate acquisition from a variety of sources, and many channel acquisition from modern multi-channel diagnostics. Hosted by a i386-Linux PC in a crate with four available PCI slots, each single-PCI slot 32-channel digitiser features sampling frequencies up to 200 kHz, and 64 MB of memory, providing 1 Msample of 16-bit data per channel. The local hard disk is used for immediate local storage of all the acquired data from the selected channels into a local MDSplus database. The host is then accessed as a MDS/IP server that provides, on demand, down-sampled and software filtered traces. The local hard disk capacity is used for medium to long-term storage and availability of the full data set with optional mirror technology to guard against hard disk failure. We have thus obtained a general solution for high resolution, multi-channel routine acquisition using the multi-platform MDSplus environment, in which different software and hardware architectures are intelligently linked across a standard TCP/IP network. The implementation presented here uses ONLY standard components of the MDSplus environment.

  1. 128 Channel PCI-based data acquisition system for MDSplus

    International Nuclear Information System (INIS)

    Llobet, Xavier; Duval, Basil P.

    2002-01-01

    With the increasing demand for analogue channel acquisition on the TCV tokamak, a new PCI based acquisition has been specified, designed, built and installed into our MDSplus acquisition environment. The design criteria were to not only improve the cost/channel, as compared to our conventional hub based acquisition (CAMAC), but to provide some distributed processing power to avoid the associated acquisition server saturation, both in terms of CPU and network bandwidth. These units were initially intended to satisfy the requirements of general variable rate acquisition from a variety of sources, and many channel acquisition from modern multi-channel diagnostics. Hosted by a i386-Linux PC in a crate with four available PCI slots, each single-PCI slot 32-channel digitiser features sampling frequencies up to 200 kHz, and 64 MB of memory, providing 1 Msample of 16-bit data per channel. The local hard disk is used for immediate local storage of all the acquired data from the selected channels into a local MDSplus database. The host is then accessed as a MDS/IP server that provides, on demand, down-sampled and software filtered traces. The local hard disk capacity is used for medium to long-term storage and availability of the full data set with optional mirror technology to guard against hard disk failure. We have thus obtained a general solution for high resolution, multi-channel routine acquisition using the multi-platform MDSplus environment, in which different software and hardware architectures are intelligently linked across a standard TCP/IP network. The implementation presented here uses ONLY standard components of the MDSplus environment

  2. Analysis of signal acquisition in GPS receiver software

    Directory of Open Access Journals (Sweden)

    Vlada S. Sokolović

    2011-01-01

    Full Text Available This paper presents a critical analysis of the flow signal processing carried out in GPS receiver software, which served as a basis for a critical comparison of different signal processing architectures within the GPS receiver. It is possible to achieve Increased flexibility and reduction of GPS device commercial costs, including those of mobile devices, by using radio technology software (SDR, Software Defined Radio. The SDR application can be realized when certain hardware components in a GPS receiver are replaced. Signal processing in the SDR is implemented using a programmable DSP (Digital Signal Processing or FPGA (Field Programmable Gate Array circuit, which allows a simple change of digital signal processing algorithms and a simple change of the receiver parameters. The starting point of the research is the signal generated on the satellite the structure of which is shown in the paper. Based on the GPS signal structure, a receiver is realized with a task to extract an appropriate signal from the spectrum and detect it. Based on collected navigation data, the receiver calculates the position of the end user. The signal coming from the satellite may be at the carrier frequencies of L1 and L2. Since the SPS is used in the civil service, all the tests shown in the work were performed on the L1 signal. The signal coming to the receiver is generated in the spread spectrum technology and is situated below the level of noise. Such signals often interfere with signals from the environment which presents a difficulty for a receiver to perform proper detection and signal processing. Therefore, signal processing technology is continually being improved, aiming at more accurate and faster signal processing. All tests were carried out on a signal acquired from the satellite using the SE4110 input circuit used for filtering, amplification and signal selection. The samples of the received signal were forwarded to a computer for data post processing, i. e

  3. Sequencing of real-world samples using a microfabricated hybrid device having unconstrained straight separation channels.

    Science.gov (United States)

    Liu, Shaorong; Elkin, Christopher; Kapur, Hitesh

    2003-11-01

    We describe a microfabricated hybrid device that consists of a microfabricated chip containing multiple twin-T injectors attached to an array of capillaries that serve as the separation channels. A new fabrication process was employed to create two differently sized round channels in a chip. Twin-T injectors were formed by the smaller round channels that match the bore of the separation capillaries and separation capillaries were incorporated to the injectors through the larger round channels that match the outer diameter of the capillaries. This allows for a minimum dead volume and provides a robust chip/capillary interface. This hybrid design takes full advantage, such as sample stacking and purification and uniform signal intensity profile, of the unique chip injection scheme for DNA sequencing while employing long straight capillaries for the separations. In essence, the separation channel length is optimized for both speed and resolution since it is unconstrained by chip size. To demonstrate the reliability and practicality of this hybrid device, we sequenced over 1000 real-world samples from Human Chromosome 5 and Ciona intestinalis, prepared at Joint Genome Institute. We achieved average Phred20 read of 675 bases in about 70 min with a success rate of 91%. For the similar type of samples on MegaBACE 1000, the average Phred20 read is about 550-600 bases in 120 min separation time with a success rate of about 80-90%.

  4. Computed tomography device

    International Nuclear Information System (INIS)

    Ohhashi, A.

    1985-01-01

    A computed tomography device comprising a subtraction unit which obtains differential data strings representing the difference between each time-serial projection data string of a group of projection data strings corresponding to a prospective reconstruction image generated by projection data strings acquired by a data acquisition system, a convolution unit which convolves each time-serial projection data string of the group of projection data strings corresponding to the prospective reconstruction image, and a back-projection unit which back-projects the convolved data strings

  5. Achieving Better Buying Power through Acquisition of Open Architecture Software Systems for Web-Based and Mobile Devices

    Science.gov (United States)

    2015-05-01

    ecosystems Software component supply network for OA system components: Component IP license and cybersecurity requirements propagate from/to Producers...acquisition and OA development ecosystems: Multiple OA system evolution paths IP and cybersecurity requirements will need continuous attention...acquisition of OA Web/mobile software components  Franchising  Enterprise licensing  Metered usage  Advertising supported  Subscription  Free

  6. Controlled power delivery for super-resolution imaging of biological samples using digital micromirror device

    Science.gov (United States)

    Valiya Peedikakkal, Liyana; Cadby, Ashley

    2017-02-01

    Localization based super resolution images of a biological sample is generally achieved by using high power laser illumination with long exposure time which unfortunately increases photo-toxicity of a sample, making super resolution microscopy, in general, incompatible with live cell imaging. Furthermore, the limitation of photobleaching reduces the ability to acquire time lapse images of live biological cells using fluorescence microscopy. Digital Light Processing (DLP) technology can deliver light at grey scale levels by flickering digital micromirrors at around 290 Hz enabling highly controlled power delivery to samples. In this work, Digital Micromirror Device (DMD) is implemented in an inverse Schiefspiegler telescope setup to control the power and pattern of illumination for super resolution microscopy. We can achieve spatial and temporal patterning of illumination by controlling the DMD pixel by pixel. The DMD allows us to control the power and spatial extent of the laser illumination. We have used this to show that we can reduce the power delivered to the sample to allow for longer time imaging in one area while achieving sub-diffraction STORM imaging in another using higher power densities.

  7. Data acquisition for X ray microprobe. User's manual

    International Nuclear Information System (INIS)

    2002-01-01

    A modified data acquisition software for X ray microprobe was developed by the Physics Group, Instrumentation Unit, IAEA Laboratories at Seibersdorf, with assistance from M. Bogovac, Croatia. The software consists of data acquisition (scanning and calibration), automatic positioning and micro-movement of sample, data reduction and evaluation. The acquisition software was designed in order to support different measurement set-ups which are applied in low-energy nuclear physics. The modification was done in 1999-2000 under the projects Nuclear Spectrometry and Utilization of Particle Accelerators. The manual supersedes the first version entitled Microanalysis Data Acquisition and Control Program published under Computer Manual Series, No. 9 in 1996. The software described in this manual is freely available from the IAEA upon request

  8. New data acquisition system for AMS

    Energy Technology Data Exchange (ETDEWEB)

    Pfenninger, R. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    A new data acquisition system based on a VME front-end computer, a Sun workstation and a PC has been installed. It is used for the acquisition of mainly AMS data, their graphical display, and storage of the data in a Oracle database. The measurement of magazines of 25 sample each is fully automated. Several data parameters such as transmission are regularly checked. In case of problems the operator is informed by optical and/or acoustical signals. Screens are updated automatically after every measurement cycle. (author) 1 fig.

  9. A data-acquisition system for high speed linear CCD

    International Nuclear Information System (INIS)

    Liu Zhiyan; Chen Xiangcai; Jiang Xiaoshan; Zhang Hongyu; Liang Zhongwang; Xiang Haisheng; Hu Jun

    2010-01-01

    A data-acquisition system for high speed linear CCD (Charge Coupled device) is mainly introduced. The optical fiber transmission technology is used. The data is sent to PC through USB or PCI interface. The construction of the system, the design of the PCI interface hardware, software design and the design of the control program running on host computer are also introduced. (authors)

  10. Embedded data acquisition system with MDSPlus

    International Nuclear Information System (INIS)

    Rajpal, Rachana; Patel, Jigneshkumar; Kumari, Praveena; Panchal, Vipul; Chattopadhyay, P.K.; Pujara, Harshad; Saxena, Y.C.

    2012-01-01

    This data acquisition system (DAS) is designed and developed to cater the increasing demand of Plasma Diagnostics for Aditya Tokamak as well as to support the basic physics research going on at Institute for Plasma Research. The main design criteria were to design a system with minimum resources and flexible to cater the needs of slow and fast diagnostic channels and can be easily integrated with the existing data acquisition system of Aditya Tokamak. The DAS is designed on embedded PC/104 platform. This is a multi channel system which supports standard features of commercially available DAS. The control and bus interface logic are implemented using Very High Speed Hardware Description Language (VHDL) on Complex Programmable Logic Device (CPLD). For Aditya Tokamak pulse experiment, the software application is designed such that the data is directly integrated to the MDSplus tree of Aditya DAS. The detailed hardware and software design, development and testing results will be discussed in the paper.

  11. Monitoring the CMS Data Acquisition System

    CERN Document Server

    Bauer, Gerry; Biery, K; Branson, J; Cano, E; Cheung, H; Ciganek, M; Cittolin, S; Coarasa, J A; Deldicque, C; Dusinberre, E; Erhan, S; Fortes Rodrigues, F; Gigi, D; Glege, F; Gomez-Reino, R; Gutleber, J; Hatton, D; Laurens, J F; Lopez Perez, J A; Meijers, F; Meschi, E; Meyer, A; Mommsen, R; Moser, R; O'Dell, V; Oh, A; Orsini, L B; Patras, V; Paus, C; Petrucci, A; Pieri, M; Racz, A; Sakulin, H; Sani, M; Schieferdecker, P; Schwick, C; Shpakov, D; Simon, S; Sumorok, K; Zanetti, M.

    2010-01-01

    The CMS data acquisition system comprises O(20000) interdependent services that need to be monitored in near real-time. The ability to monitor a large number of distributed applications accurately and effectively is of paramount importance for robust operations. Application monitoring entails the collection of a large number of simple and composed values made available by the software components and hardware devices. A key aspect is that detection of deviations from a specified behaviour is supported in a timely manner, which is a prerequisite in order to take corrective actions efficiently. Given the size and time constraints of the CMS data acquisition system, efficient application monitoring is an interesting research problem. We propose an approach that uses the emerging paradigm of Web-service based eventing systems in combination with hierarchical data collection and load balancing. Scalability and efficiency are achieved by a decentralized architecture, splitting up data collections into regions of col...

  12. Scanning SQUID microscope with an in-situ magnetization/demagnetization field for geological samples

    Science.gov (United States)

    Du, Junwei; Liu, Xiaohong; Qin, Huafeng; Wei, Zhao; Kong, Xiangyang; Liu, Qingsong; Song, Tao

    2018-04-01

    Magnetic properties of rocks are crucial for paleo-, rock-, environmental-magnetism, and magnetic material sciences. Conventional rock magnetometers deal with bulk properties of samples, whereas scanning microscope can map the distribution of remanent magnetization. In this study, a new scanning microscope based on a low-temperature DC superconducting quantum interference device (SQUID) equipped with an in-situ magnetization/demagnetization device was developed. To realize the combination of sensitive instrument as SQUID with high magnetizing/demagnetizing fields, the pick-up coil, the magnetization/demagnetization coils and the measurement mode of the system were optimized. The new microscope has a field sensitivity of 250 pT/√Hz at a coil-to-sample spacing of ∼350 μm, and high magnetization (0-1 T)/ demagnetization (0-300 mT, 400 Hz) functions. With this microscope, isothermal remanent magnetization (IRM) acquisition and the according alternating field (AF) demagnetization curves can be obtained for each point without transferring samples between different procedures, which could result in position deviation, waste of time, and other interferences. The newly-designed SQUID microscope, thus, can be used to investigate the rock magnetic properties of samples at a micro-area scale, and has a great potential to be an efficient tool in paleomagnetism, rock magnetism, and magnetic material studies.

  13. Ball assisted device for analytical surface sampling

    Science.gov (United States)

    ElNaggar, Mariam S; Van Berkel, Gary J; Covey, Thomas R

    2015-11-03

    A system for sampling a surface includes a sampling probe having a housing and a socket, and a rolling sampling sphere within the socket. The housing has a sampling fluid supply conduit and a sampling fluid exhaust conduit. The sampling fluid supply conduit supplies sampling fluid to the sampling sphere. The sampling fluid exhaust conduit has an inlet opening for receiving sampling fluid carried from the surface by the sampling sphere. A surface sampling probe and a method for sampling a surface are also disclosed.

  14. DO INFANTS USING BABY WALKERS SUFFER DEVELOPMENTAL DELAYS IN ACQUISITION OF MOTOR SKILLS?

    OpenAIRE

    A. Talebian; A. Honarpishe; A. Taghavi; E. Fakharian; M. Parsa; GA. Mousavi

    2008-01-01

     AbstractObjectiveDevelopment is a complex process, completed over a specific period of time, through the maturation of the nervous system. It is affected by genetic, ethnic, nutritional, social, and economic factors; one of the environmental factors affecting the acquisition of motor skills in infants is the use of baby walkers. Since this device is very commonly used for infants in our country, we conducted this study to evaluate its effects on the acquisition of motor skills in this age gr...

  15. Predictors of chain acquisition among independent dialysis facilities.

    Science.gov (United States)

    Pozniak, Alyssa S; Hirth, Richard A; Banaszak-Holl, Jane; Wheeler, John R C

    2010-04-01

    To determine the predictors of chain acquisition among independent dialysis providers. Retrospective facility-level data combined from CMS Cost Reports, Medical Evidence Forms, Annual Facility Surveys, and claims for 1996-2003. Independent dialysis facilities' probability of acquisition by a dialysis chain (overall and by chain size) was estimated using a discrete time hazard rate model, controlling for financial and clinical performance, practice patterns, market factors, and other facility characteristics. The sample includes all U.S. freestanding dialysis facilities that report not being chain affiliated for at least 1 year between 1997 and 2003. Above-average costs and better quality outcomes are significant determinants of dialysis chain acquisition. Facilities in larger markets were more likely to be acquired by a chain. Furthermore, small dialysis chains have different acquisition strategies than large chains. Dialysis chains appear to employ a mix of turn-around and cream-skimming strategies. Poor financial health is a predictor of chain acquisition as in other health care sectors, but the increased likelihood of chain acquisition among higher quality facilities is unique to the dialysis industry. Significant differences among predictors of acquisition by small and large chains reinforce the importance of using a richer classification for chain status.

  16. Study of microtip-based extraction and purification of DNA from human samples for portable devices

    Science.gov (United States)

    Fotouhi, Gareth

    DNA sample preparation is essential for genetic analysis. However, rapid and easy-to-use methods are a major challenge to obtaining genetic information. Furthermore, DNA sample preparation technology must follow the growing need for point-of-care (POC) diagnostics. The current use of centrifuges, large robots, and laboratory-intensive protocols has to be minimized to meet the global challenge of limited access healthcare by bringing the lab to patients through POC devices. To address these challenges, a novel extraction method of genomic DNA from human samples is presented by using heat-cured polyethyleneimine-coated microtips generating a high electric field. The microtip extraction method is based on recent work using an electric field and capillary action integrated into an automated device. The main challenges to the method are: (1) to obtain a stable microtip surface for the controlled capture and release of DNA and (2) to improve the recovery of DNA from samples with a high concentration of inhibitors, such as human samples. The present study addresses these challenges by investigating the heat curing of polyethyleneimine (PEI) coated on the surface of the microtip. Heat-cured PEI-coated microtips are shown to control the capture and release of DNA. Protocols are developed for the extraction and purification of DNA from human samples. Heat-cured PEI-coated microtip methods of DNA sample preparation are used to extract genomic DNA from human samples. It is discovered through experiment that heat curing of a PEI layer on a gold-coated surface below 150°C could inhibit the signal of polymerase chain reaction (PCR). Below 150°C, the PEI layer is not completely cured and dissolved off the gold-coated surface. Dissolved PEI binds with DNA to inhibit PCR. Heat curing of a PEI layer above 150°C on a gold-coated surface prevents inhibition to PCR and gel electrophoresis. In comparison to gold-coated microtips, the 225°C-cured PEI-coated microtips improve the

  17. Speckle-illuminated fluorescence confocal microscopy, using a digital micro-mirror device

    International Nuclear Information System (INIS)

    Jiang, Shi-Hong; Walker, John G

    2009-01-01

    An implementation of a speckle-illuminated fluorescence confocal microscope using a digital micro-mirror device (DMD) is described. The DMD not only projects a sequence of imaged binary speckle patterns onto the specimen at a very high frame rate but also operates as a spatial light modulator to perform real-time optical data processing. Frame averaging is accomplished by CCD charge accumulation during a single exposure. The recorded time-averaged image is a confocal image plus an unwanted non-confocal image which can be removed by recording a separate image. Experimental results with image acquisition within a fraction of a second are shown. Images of a thin biological sample are also shown to demonstrate practical application of the technique

  18. Development Of Data Acquisition Software For Centralized Radiation Monitoring System

    International Nuclear Information System (INIS)

    Nolida Yussup; Maslina Mohd Ibrahim; Mohd Fauzi Haris; Syirrazie Che Soh; Harzawardi Hasim; Azraf Azman; Mohd Ashhar Khalid

    2014-01-01

    Nowadays, with the growth of technology, many devices and equipment's can be connected to the network and internet to enable online data acquisition. Centralized radiation monitoring system utilizes a Local Area Network (LAN) as a communication media for data acquisition of the area radiation levels from radiation detectors in Malaysian Nuclear Agency (Nuclear Malaysia). The development of the system involves device configuration, wiring, network and hardware installation, software and web development. This paper describes the software development on the system server that is responsible to acquire and record the area radiation readings from the detectors. Then the recorded readings are called in a web programming to be displayed on a web site. The readings with the time stamp are stored in the system database for query. Besides acquiring the area radiation levels in Nuclear Malaysia centrally, additional features such as data conversion from mR to μSv and line chart display are developed in the software for effective radiation level trend observation and studies. (author)

  19. All-integrated and highly sensitive paper based device with sample treatment platform for Cd2+ immunodetection in drinking/tap waters.

    Science.gov (United States)

    López Marzo, Adaris M; Pons, Josefina; Blake, Diane A; Merkoçi, Arben

    2013-04-02

    Nowadays, the development of systems, devices, or methods that integrate several process steps into one multifunctional step for clinical, environmental, or industrial purposes constitutes a challenge for many ongoing research projects. Here, we present a new integrated paper based cadmium (Cd(2+)) immunosensing system in lateral flow format, which integrates the sample treatment process with the analyte detection process. The principle of Cd(2+) detection is based on competitive reaction between the cadmium-ethylenediaminetetraacetic acid-bovine serum albumin-gold nanoparticles (Cd-EDTA-BSA-AuNP) conjugate deposited on the conjugation pad strip and the Cd-EDTA complex formed in the analysis sample for the same binding sites of the 2A81G5 monoclonal antibody (mAb), specific to Cd-EDTA but not Cd(2+) free, which is immobilized onto the test line. This platform operates without any sample pretreatment step for Cd(2+) detection thanks to an extra conjugation pad that ensures Cd(2+) complexation with EDTA and interference masking through ovalbumin (OVA). The detection and quantification limits found for the device were 0.1 and 0.4 ppb, respectively, these being the lowest limits reported up to now for metal sensors based on paper. The accuracy of the device was evaluated by addition of known quantities of Cd(2+) to different drinking water samples and subsequent Cd(2+) content analysis. Sample recoveries ranged from 95 to 105% and the coefficient of variation for the intermediate precision assay was less than 10%. In addition, the results obtained here were compared with those obtained with the well-established inductively coupled plasma emission spectroscopy (ICPES) and the analysis of certificate standard samples.

  20. Image acquisition and analysis for beam diagnostics, applications of the Taiwan photon source

    International Nuclear Information System (INIS)

    Liao, C.Y.; Chen, J.; Cheng, Y.S.; Hsu, K.T.; Hu, K.H.; Kuo, C.H.; Wu, C.Y.

    2012-01-01

    Design and implementation of image acquisition and analysis is in proceeding for the Taiwan Photon Source (TPS) diagnostic applications. The optical system contains screen, lens, and lighting system. A CCD camera with Gigabit Ethernet interface (GigE Vision) will be a standard image acquisition device. Image acquisition will be done on EPICS IOC via PV channel and analysis the properties by using Matlab tool to evaluate the beam profile (sigma), beam size position and tilt angle et al. The EPICS IOC integrated with Matlab as a data processing system is not only could be used in image analysis but also in many types of equipment data processing applications. Progress of the project will be summarized in this report. (authors)

  1. Wide-range bipolar pulse conductance instrument employing current and voltage modes with sampled or integrated signal acquisition

    Energy Technology Data Exchange (ETDEWEB)

    Calhoun, R K; Holler, F J [Kentucky Univ., Lexington, KY (United States). Dept. of Chemistry; Geiger, jr, R F; Nieman, T A [Illinois Univ., Urbana, IL (United States). Dept. of Chemistry; Caserta, K J [Procter and Gamble Co., Cincinnati, OH (United States)

    1991-11-05

    An instrument for measuring solution conductance using the bipolar pulse technique is described. The instrument is capable of measuring conductances in the range of 5x10{sup -9}-10{Omega}{sup -1} with 1% accuracy or better in as little as 32 {mu}s. Accuracy of 0.001-0.01% is achievable over the range 1x10{sup -6}-1{Omega}{sup -1}. Circuitry and software are described that allow the instrument to adjust automatically the pulse height, pulse duration, excitation mode (current or voltage pulse) and data acquisition mode (sampled or integrated) to acquire data of optimum accuracy and precision. The urease-catalyzed decomposition of urea is used to illustrate the versality of the instrument, and other applications are cited. (author). 60 refs.; 7 figs.; 2 tabs.

  2. Image timing and detector performance of a matrix ion-chamber electronic portal imaging device

    International Nuclear Information System (INIS)

    Greer, P.

    1996-01-01

    The Oncology Centre of Auckland Hospital recently purchased a Varian PortalVision TM electronic portal imaging device (EPID). Image acquisition times, input-output characteristics and contrast-detail curves of this matrix liquid ion-chamber EPID have been measured to examine the variation in imaging performance with acquisition mode. The variation in detector performance with acquisition mode has been examined. The HV cycle time can be increased to improve image quality. Consideration should be given to the acquisition mode and HV cycle time used when imaging to ensure adequate imaging performance with reasonable imaging time. (author)

  3. Proposed data acquisition system for the Fermilab Booster

    International Nuclear Information System (INIS)

    Bharadwaj, V.; Peggs, S.; Wu, G.; Saltmarsh, C.

    1991-01-01

    At present, studies involving the FNAL Booster (or in fact most accelerators) depend on knowing exactly what detector one has to look at and at what time. Because of this, most studies are done 'on-line' and involve looking for repetitive effects using a limited number of detectors. In this paper the authors propose to design a Booster Data Acquisition System (BDAQ) for the FNAL Booster. In essence this system consists of a large number of digitizers with circular memory buffers. After a machine cycle of interest, these buffers are frozen and then read out into a mass storage device. This paper discusses the hardware and software capabilities needed to make such a data acquisition system a powerful tool for doing accelerator physics studies and improving machine performance

  4. Modular data acquisition system and its use in gas-filled detector readout at ESRF

    International Nuclear Information System (INIS)

    Sever, F.; Epaud, F.; Poncet, F.; Grave, M.; Rey-Bakaikoa, V.

    1996-01-01

    Since 1992, 18 ESRF beamlines are open to users. Although the data acquisition requirements vary a lot from one beamline to another, we are trying to implement a modular data acquisition system architecture that would fit with the maximum number of acquisition projects at ESRF. Common to all of these systems are large acquisition memories and the requirement to visualize the data during an acquisition run and to transfer them quickly after the run to safe storage. We developed a general memory API handling the acquisition memory and its organization and another library that provides calls for transferring the data over TCP/IP sockets. Interesting utility programs using these libraries are the open-quote online display close-quote program and the open-quote data transfer close-quote program. The data transfer program as well as an acquisition control program rely on our well-established open-quote device server model close-quote, which was originally designed for the machine control system and then successfully reused in beamline control systems. In the second half of this paper, the acquisition system for a 2D gas-filled detector is presented, which is one of the first concrete examples using the proposed modular data acquisition architecture. copyright 1996 American Institute of Physics

  5. Developed a needle trap device with PDMS sorbent for microextraction of toluene and methyl ethyl ketone from aquatic samples using dynamic headspace

    Directory of Open Access Journals (Sweden)

    Sara Karimi Zeverdegani

    2016-09-01

    Full Text Available Introduction: Due to the widespread use of toxic chemicals in most workplaces that can lead to toxic effects on human, various chemical extraction technique have been defined for analysis these toxic substances in air, water and biological samples. The purpose of this research is extraction of  toluene and methyl ethyl ketone from aquatic samples with needle trap device and  one commercial sorbent. Methods: In this research, needle trap device was used to extraction of  toluene and methyl ethyl ketone in aquatic samples, so needles(size 20 were packed with PDMS and extraction was done with dynamic headspace needle trap device. Gas chromatography with - flame ionization detector was used to analysis and optimized extraction of two substances were obtained. Results: Results show that the optimum temperature and time extraction was similar for toluene and methyl ethyl ketone (30 ° C, 30 min, but the reproducibility of results and calibration curve that obtained for toluene was better than methyl ethyl ketone. Conclusion: Needle trap technique is inexpensive, sensitive and portable also this method has good recovery to extract small amounts of  toluene and methyl ethyketon from aquatic samples with polydimethylsiloxane.

  6. Development of high-availability ATCA/PCIe data acquisition instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Correia, Miguel; Sousa, Jorge; Batista, Antonio J.N.; Combo, Alvaro; Santos, Bruno; Rodrigues, Antonio P.; Carvalho, Paulo F.; Goncalves, Bruno [Instituto de Plasmas e Fusao Nuclear, Instituto Superior Tecnico, Universidade de Lisboa, 1049- 001 Lisboa (Portugal); Correia, Carlos M.B.A. [Centro de Instrumentacao, Dept. de Fisica, Universidade de Coimbra, 3004-516 Coimbra (Portugal)

    2015-07-01

    Latest Fusion energy experiments envision a quasi-continuous operation regime. In consequence, the largest experimental devices, currently in development, specify high-availability (HA) requirements for the whole plant infrastructure. HA features enable the whole facility to perform seamlessly in the case of failure of any of its components, coping with the increasing duration of plasma discharges (steady-state) and assuring safety of equipment, people, environment and investment. IPFN developed a control and data acquisition system, aiming for fast control of advanced Fusion devices, which is thus required to provide such HA features. The system is based on in-house developed Advanced Telecommunication Computing Architecture (ATCA) instrumentation modules - IO blades and data switch blades, establishing a PCIe network on the ATCA shelf's back-plane. The data switch communicates to an external host computer through a PCIe data network. At the hardware management level, the system architecture takes advantage of ATCA native redundancy and hot swap specifications to implement fail-over substitution of IO or data switch blades. A redundant host scheme is also supported by the ATCA/PCIe platform. At the software level, PCIe provides implementation of hot plug services, which translate the hardware changes to the corresponding software/operating system devices. The paper presents how the ATCA and PCIe based system can be setup to perform with the desired degree of HA, thus being suitable for advanced Fusion control and data acquisition systems. (authors)

  7. Development of high-availability ATCA/PCIe data acquisition instrumentation

    International Nuclear Information System (INIS)

    Correia, Miguel; Sousa, Jorge; Batista, Antonio J.N.; Combo, Alvaro; Santos, Bruno; Rodrigues, Antonio P.; Carvalho, Paulo F.; Goncalves, Bruno; Correia, Carlos M.B.A.

    2015-01-01

    Latest Fusion energy experiments envision a quasi-continuous operation regime. In consequence, the largest experimental devices, currently in development, specify high-availability (HA) requirements for the whole plant infrastructure. HA features enable the whole facility to perform seamlessly in the case of failure of any of its components, coping with the increasing duration of plasma discharges (steady-state) and assuring safety of equipment, people, environment and investment. IPFN developed a control and data acquisition system, aiming for fast control of advanced Fusion devices, which is thus required to provide such HA features. The system is based on in-house developed Advanced Telecommunication Computing Architecture (ATCA) instrumentation modules - IO blades and data switch blades, establishing a PCIe network on the ATCA shelf's back-plane. The data switch communicates to an external host computer through a PCIe data network. At the hardware management level, the system architecture takes advantage of ATCA native redundancy and hot swap specifications to implement fail-over substitution of IO or data switch blades. A redundant host scheme is also supported by the ATCA/PCIe platform. At the software level, PCIe provides implementation of hot plug services, which translate the hardware changes to the corresponding software/operating system devices. The paper presents how the ATCA and PCIe based system can be setup to perform with the desired degree of HA, thus being suitable for advanced Fusion control and data acquisition systems. (authors)

  8. Data acquisition system in TPE-1RM15

    International Nuclear Information System (INIS)

    Yagi, Yasuyuki; Yahagi, Eiichi; Hirano, Yoichi; Shimada, Toshio; Hirota, Isao; Maejima, Yoshiki

    1991-01-01

    The data acquisition system for TPE-1RM15 reversed field pinch machine had been developed and has recently been completed. Thd data to be acquired consist of many channels of time series data which come from plasma diagnostics. The newly developed data acquisition system uses CAMAC (Computer Automated Measurement And Control) system as a front end data acquisition system and micro-VAX II for control, file management and analyses. Special computer programs, DAQR/D, have been developed for data acquisition routine. Experimental setting and process controlling items are managed by a parameter database in a shared common region and every task can easily refer to it. The acquired data are stored into a mass storage system (total of 1.3GBytes plus a magnetic tape system) including an optical disk system, which can save storage space and allow quick reference. At present, the CAMAC system has 88 (1MHz sampling) and 64(5kHz sampling) channels corresponding to 1.6 MBytes per shot. The data acquisition system can finish one routine within 5 minutes with 1.6MBytes data depending on the amount of graphic outputs. Hardwares and softwares of the system are specified so that the system can be easily expanded. The computer is connected to the AIST Ethernet and the system can be remotely accessed and the acquired data can be transferred to the mainframes on the network. Details about specifications and performance of the system are given in this report. (author)

  9. Miniaturized bead-beating device to automate full DNA sample preparation processes for gram-positive bacteria.

    Science.gov (United States)

    Hwang, Kyu-Youn; Kwon, Sung Hong; Jung, Sun-Ok; Lim, Hee-Kyun; Jung, Won-Jong; Park, Chin-Sung; Kim, Joon-Ho; Suh, Kahp-Yang; Huh, Nam

    2011-11-07

    We have developed a miniaturized bead-beating device to automate nucleic acids extraction from Gram-positive bacteria for molecular diagnostics. The microfluidic device was fabricated by sandwiching a monolithic flexible polydimethylsiloxane (PDMS) membrane between two glass wafers (i.e., glass-PDMS-glass), which acted as an actuator for bead collision via its pneumatic vibration without additional lysis equipment. The Gram-positive bacteria, S. aureus and methicillin-resistant S. aureus, were captured on surface-modified glass beads from 1 mL of initial sample solution and in situ lyzed by bead-beating operation. Then, 10 μL or 20 μL of bacterial DNA solution was eluted and amplified successfully by real-time PCR. It was found that liquid volume fraction played a crucial role in determining the cell lysis efficiency in a confined chamber by facilitating membrane deflection and bead motion. The miniaturized bead-beating operation disrupted most of S. aureus within 3 min, which turned out to be as efficient as the conventional benchtop vortexing machine or the enzyme-based lysis technique. The effective cell concentration was significantly enhanced with the reduction of initial sample volume by 50 or 100 times. Combination of such analyte enrichment and in situ bead-beating lysis provided an excellent PCR detection sensitivity amounting to ca. 46 CFU even for the Gram-positive bacteria. The proposed bead-beating microdevice is potentially useful as a nucleic acid extraction method toward a PCR-based sample-to-answer system. This journal is © The Royal Society of Chemistry 2011

  10. Bipolar Electrode Sample Preparation Devices

    Science.gov (United States)

    Wang, Yi (Inventor); Song, Hongjun (Inventor); Pant, Kapil (Inventor)

    2017-01-01

    An analyte selection device can include: a body defining a fluid channel having a channel inlet and channel outlet; a bipolar electrode (BPE) between the inlet and outlet; one of an anode or cathode electrically coupled with the BPE on a channel inlet side of the BPE and the other of the anode or cathode electrically coupled with the BPE on a channel outlet side of the BPE; and an electronic system operably coupled with the anode and cathode so as to polarize the BPE. The fluid channel can have any shape or dimension. The channel inlet and channel outlet can be longitudinal or lateral with respect to the longitudinal axis of the channel. The BPE can be any metallic member, such as a flat plate on a wall or mesh as a barrier BPE. The anode and cathode can be located at a position that polarizes the BPE.

  11. Clustered data acquisition for the CMS experiment

    International Nuclear Information System (INIS)

    Gutleber, J.; Antchev, G.; Cano, E.; Csilling, A.; Cittolin, S.; Gigi, D.; Gras, P.; Jacobs, C.; Meijers, F.; Meschi, E.; Oh, A.; Orsini, L.; Pollet, L.; Racz, A.; Samyn, D.; Schwick, C.; Zangrando, L.; Erhan, S.; Gulmini, M.; Sphicas, P.; Ninane, A.

    2001-01-01

    Powerful mainstream computing equipment and the advent of affordable multi-Gigabit communication technology allow us to tackle data acquisition problems with clusters of inexpensive computers. Such networks typically incorporate heterogeneous platforms, real-time partitions and custom devices. Therefore, one must strive for a software infrastructure that efficiently combines the nodes to a single, unified resource for the user. Overall requirements for such middleware are high efficiency and configuration flexibility. Intelligent I/O (I 2 O) is an industry specification that defines a uniform messaging format and executing model for processor-enabled communication equipment. Mapping this concept to a distributed computing environment and encapsulating the details of the specification into an application-programming framework allow us to provide run-time support for cluster operation. The authors give a brief overview of a framework, XDAQ that we designed and implemented at CERN for the Compact Muon Solenoid experiment's prototype data acquisition system

  12. Study on highly efficient seismic data acquisition and processing methods based on sparsity constraint

    Science.gov (United States)

    Wang, H.; Chen, S.; Tao, C.; Qiu, L.

    2017-12-01

    High-density, high-fold and wide-azimuth seismic data acquisition methods are widely used to overcome the increasingly sophisticated exploration targets. The acquisition period is longer and longer and the acquisition cost is higher and higher. We carry out the study of highly efficient seismic data acquisition and processing methods based on sparse representation theory (or compressed sensing theory), and achieve some innovative results. The theoretical principles of highly efficient acquisition and processing is studied. We firstly reveal sparse representation theory based on wave equation. Then we study the highly efficient seismic sampling methods and present an optimized piecewise-random sampling method based on sparsity prior information. At last, a reconstruction strategy with the sparsity constraint is developed; A two-step recovery approach by combining sparsity-promoting method and hyperbolic Radon transform is also put forward. The above three aspects constitute the enhanced theory of highly efficient seismic data acquisition. The specific implementation strategies of highly efficient acquisition and processing are studied according to the highly efficient acquisition theory expounded in paragraph 2. Firstly, we propose the highly efficient acquisition network designing method by the help of optimized piecewise-random sampling method. Secondly, we propose two types of highly efficient seismic data acquisition methods based on (1) single sources and (2) blended (or simultaneous) sources. Thirdly, the reconstruction procedures corresponding to the above two types of highly efficient seismic data acquisition methods are proposed to obtain the seismic data on the regular acquisition network. A discussion of the impact on the imaging result of blended shooting is discussed. In the end, we implement the numerical tests based on Marmousi model. The achieved results show: (1) the theoretical framework of highly efficient seismic data acquisition and processing

  13. Dumand-array data-acquisition system

    International Nuclear Information System (INIS)

    Brenner, A.E.; Theriot, D.; Dau, W.D.; Geelhood, B.D.; Harris, F.; Learned, J.G.; Stenger, V.; March, R.; Roos, C.; Shumard, E.

    1982-04-01

    An overall data acquisition approach for DUMAND is described. The scheme assumes one array to shore optical fiber transmission line for each string of the array. The basic event sampling period is approx. 13 μsec. All potentially interesting data is transmitted to shore where the major processing is performed

  14. Liquid Acquisition Device Hydrogen Outflow Testing on the Cryogenic Propellant Storage and Transfer Engineering Design Unit

    Science.gov (United States)

    Zimmerli, Greg; Statham, Geoff; Garces, Rachel; Cartagena, Will

    2015-01-01

    As part of the NASA Cryogenic Propellant Storage and Transfer (CPST) Engineering Design Unit (EDU) testing with liquid hydrogen, screen-channel liquid acquisition devices (LADs) were tested during liquid hydrogen outflow from the EDU tank. A stainless steel screen mesh (325x2300 Dutch T will weave) was welded to a rectangular cross-section channel to form the basic LAD channel. Three LAD channels were tested, each having unique variations in the basic design. The LADs fed a common outflow sump at the aft end of the 151 cu. ft. volume aluminum tank, and included a curved section along the aft end and a straight section along the barrel section of the tank. Wet-dry sensors were mounted inside the LAD channels to detect when vapor was ingested into the LADs during outflow. The use of warm helium pressurant during liquid hydrogen outflow, supplied through a diffuser at the top of the tank, always led to early breakdown of the liquid column. When the tank was pressurized through an aft diffuser, resulting in cold helium in the ullage, LAD column hold-times as long as 60 minutes were achieved, which was the longest duration tested. The highest liquid column height at breakdown was 58 cm, which is 23 less than the isothermal bubble-point model value of 75 cm. This paper discusses details of the design, construction, operation and analysis of LAD test data from the CPST EDU liquid hydrogen test.

  15. Data Acquisition (DAQ) system dedicated for remote sensing applications on Unmanned Aerial Vehicles (UAV)

    Science.gov (United States)

    Keleshis, C.; Ioannou, S.; Vrekoussis, M.; Levin, Z.; Lange, M. A.

    2014-08-01

    Continuous advances in unmanned aerial vehicles (UAV) and the increased complexity of their applications raise the demand for improved data acquisition systems (DAQ). These improvements may comprise low power consumption, low volume and weight, robustness, modularity and capability to interface with various sensors and peripherals while maintaining the high sampling rates and processing speeds. Such a system has been designed and developed and is currently integrated on the Autonomous Flying Platforms for Atmospheric and Earth Surface Observations (APAESO/NEA-YΠOΔOMH/NEKΠ/0308/09) however, it can be easily adapted to any UAV or any other mobile vehicle. The system consists of a single-board computer with a dual-core processor, rugged surface-mount memory and storage device, analog and digital input-output ports and many other peripherals that enhance its connectivity with various sensors, imagers and on-board devices. The system is powered by a high efficiency power supply board. Additional boards such as frame-grabbers, differential global positioning system (DGPS) satellite receivers, general packet radio service (3G-4G-GPRS) modems for communication redundancy have been interfaced to the core system and are used whenever there is a mission need. The onboard DAQ system can be preprogrammed for automatic data acquisition or it can be remotely operated during the flight from the ground control station (GCS) using a graphical user interface (GUI) which has been developed and will also be presented in this paper. The unique design of the GUI and the DAQ system enables the synchronized acquisition of a variety of scientific and UAV flight data in a single core location. The new DAQ system and the GUI have been successfully utilized in several scientific UAV missions. In conclusion, the novel DAQ system provides the UAV and the remote-sensing community with a new tool capable of reliably acquiring, processing, storing and transmitting data from any sensor integrated

  16. A compact electroencephalogram recording device with integrated audio stimulation system

    Science.gov (United States)

    Paukkunen, Antti K. O.; Kurttio, Anttu A.; Leminen, Miika M.; Sepponen, Raimo E.

    2010-06-01

    A compact (96×128×32 mm3, 374 g), battery-powered, eight-channel electroencephalogram recording device with an integrated audio stimulation system and a wireless interface is presented. The recording device is capable of producing high-quality data, while the operating time is also reasonable for evoked potential studies. The effective measurement resolution is about 4 nV at 200 Hz sample rate, typical noise level is below 0.7 μVrms at 0.16-70 Hz, and the estimated operating time is 1.5 h. An embedded audio decoder circuit reads and plays wave sound files stored on a memory card. The activities are controlled by an 8 bit main control unit which allows accurate timing of the stimuli. The interstimulus interval jitter measured is less than 1 ms. Wireless communication is made through bluetooth and the data recorded are transmitted to an external personal computer (PC) interface in real time. The PC interface is implemented with LABVIEW® and in addition to data acquisition it also allows online signal processing, data storage, and control of measurement activities such as contact impedance measurement, for example. The practical application of the device is demonstrated in mismatch negativity experiment with three test subjects.

  17. A Lab on a chip device for rapid identification of Avian Influenza virus by on-chip sample preparation and solid phase PCR

    DEFF Research Database (Denmark)

    Yi, Sun; Dhumpa, Raghuram; Bang, Dang Duong

    2009-01-01

    In this paper, we describe a novel lab-on-a-chip device for fast AIV screening by integrating DNA microarray-based solid phase PCR on microchip. The device can handle viral samples in an automatic way. Moreover, multiplex PCR and sequence detection are done in one-step, which greatly simplifies...

  18. Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Greer, Peter B.; Popescu, Carmen C.

    2003-01-01

    Dosimetric properties of an amorphous silicon electronic portal imaging device (EPID) for verification of dynamic intensity modulated radiation therapy (IMRT) delivery were investigated. The EPID was utilized with continuous frame-averaging during the beam delivery. Properties studied included effect of buildup, dose linearity, field size response, sampling of rapid multileaf collimator (MLC) leaf speeds, response to dose-rate fluctuations, memory effect, and reproducibility. The dependence of response on EPID calibration and a dead time in image frame acquisition occurring every 64 frames were measured. EPID measurements were also compared to ion chamber and film for open and wedged static fields and IMRT fields. The EPID was linear with dose and dose rate, and response to MLC leaf speeds up to 2.5 cm s-1 was found to be linear. A field size dependent response of up to 5% relative to d max ion-chamber measurement was found. Reproducibility was within 0.8% (1 standard deviation) for an IMRT delivery recorded at intervals over a period of one month. The dead time in frame acquisition resulted in errors in the EPID that increased with leaf speed and were over 20% for a 1 cm leaf gap moving at 1.0 cm s-1. The EPID measurements were also found to depend on the input beam profile utilized for EPID flood-field calibration. The EPID shows promise as a device for verification of IMRT, the major limitation currently being due to dead-time in frame acquisition

  19. Integrative Multi-Spectral Sensor Device for Far-Infrared and Visible Light Fusion

    Science.gov (United States)

    Qiao, Tiezhu; Chen, Lulu; Pang, Yusong; Yan, Gaowei

    2018-06-01

    Infrared and visible light image fusion technology is a hot spot in the research of multi-sensor fusion technology in recent years. Existing infrared and visible light fusion technologies need to register before fusion because of using two cameras. However, the application effect of the registration technology has yet to be improved. Hence, a novel integrative multi-spectral sensor device is proposed for infrared and visible light fusion, and by using the beam splitter prism, the coaxial light incident from the same lens is projected to the infrared charge coupled device (CCD) and visible light CCD, respectively. In this paper, the imaging mechanism of the proposed sensor device is studied with the process of the signals acquisition and fusion. The simulation experiment, which involves the entire process of the optic system, signal acquisition, and signal fusion, is constructed based on imaging effect model. Additionally, the quality evaluation index is adopted to analyze the simulation result. The experimental results demonstrate that the proposed sensor device is effective and feasible.

  20. Acquisition of German Pluralization Rules in Monolingual and Multilingual Children

    Science.gov (United States)

    Zaretsky, Eugen; Lange, Benjamin P.; Euler, Harald A.; Neumann, Katrin

    2013-01-01

    Existing studies on plural acquisition in German have relied on small samples and thus hardly deliver generalizable and differentiated results. Here, overgeneralizations of certain plural allomorphs and other tendencies in the acquisition of German plural markers are described on the basis of test data from 7,394 3- to 5-year-old monolingual…

  1. A seamless acquisition digital storage oscilloscope with three-dimensional waveform display

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Kuojun, E-mail: kuojunyang@gmail.com; Guo, Lianping [School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu (China); School of Electrical and Electronic Engineering, Nanyang Technological University (Singapore); Tian, Shulin; Zeng, Hao [School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu (China); Qiu, Lei [School of Electrical and Electronic Engineering, Nanyang Technological University (Singapore)

    2014-04-15

    In traditional digital storage oscilloscope (DSO), sampled data need to be processed after each acquisition. During data processing, the acquisition is stopped and oscilloscope is blind to the input signal. Thus, this duration is called dead time. With the rapid development of modern electronic systems, the effect of infrequent events becomes significant. To capture these occasional events in shorter time, dead time in traditional DSO that causes the loss of measured signal needs to be reduced or even eliminated. In this paper, a seamless acquisition oscilloscope without dead time is proposed. In this oscilloscope, three-dimensional waveform mapping (TWM) technique, which converts sampled data to displayed waveform, is proposed. With this technique, not only the process speed is improved, but also the probability information of waveform is displayed with different brightness. Thus, a three-dimensional waveform is shown to the user. To reduce processing time further, parallel TWM which processes several sampled points simultaneously, and dual-port random access memory based pipelining technique which can process one sampling point in one clock period are proposed. Furthermore, two DDR3 (Double-Data-Rate Three Synchronous Dynamic Random Access Memory) are used for storing sampled data alternately, thus the acquisition can continue during data processing. Therefore, the dead time of DSO is eliminated. In addition, a double-pulse test method is adopted to test the waveform capturing rate (WCR) of the oscilloscope and a combined pulse test method is employed to evaluate the oscilloscope's capture ability comprehensively. The experiment results show that the WCR of the designed oscilloscope is 6 250 000 wfms/s (waveforms per second), the highest value in all existing oscilloscopes. The testing results also prove that there is no dead time in our oscilloscope, thus realizing the seamless acquisition.

  2. A seamless acquisition digital storage oscilloscope with three-dimensional waveform display

    Science.gov (United States)

    Yang, Kuojun; Tian, Shulin; Zeng, Hao; Qiu, Lei; Guo, Lianping

    2014-04-01

    In traditional digital storage oscilloscope (DSO), sampled data need to be processed after each acquisition. During data processing, the acquisition is stopped and oscilloscope is blind to the input signal. Thus, this duration is called dead time. With the rapid development of modern electronic systems, the effect of infrequent events becomes significant. To capture these occasional events in shorter time, dead time in traditional DSO that causes the loss of measured signal needs to be reduced or even eliminated. In this paper, a seamless acquisition oscilloscope without dead time is proposed. In this oscilloscope, three-dimensional waveform mapping (TWM) technique, which converts sampled data to displayed waveform, is proposed. With this technique, not only the process speed is improved, but also the probability information of waveform is displayed with different brightness. Thus, a three-dimensional waveform is shown to the user. To reduce processing time further, parallel TWM which processes several sampled points simultaneously, and dual-port random access memory based pipelining technique which can process one sampling point in one clock period are proposed. Furthermore, two DDR3 (Double-Data-Rate Three Synchronous Dynamic Random Access Memory) are used for storing sampled data alternately, thus the acquisition can continue during data processing. Therefore, the dead time of DSO is eliminated. In addition, a double-pulse test method is adopted to test the waveform capturing rate (WCR) of the oscilloscope and a combined pulse test method is employed to evaluate the oscilloscope's capture ability comprehensively. The experiment results show that the WCR of the designed oscilloscope is 6 250 000 wfms/s (waveforms per second), the highest value in all existing oscilloscopes. The testing results also prove that there is no dead time in our oscilloscope, thus realizing the seamless acquisition.

  3. A seamless acquisition digital storage oscilloscope with three-dimensional waveform display

    International Nuclear Information System (INIS)

    Yang, Kuojun; Guo, Lianping; Tian, Shulin; Zeng, Hao; Qiu, Lei

    2014-01-01

    In traditional digital storage oscilloscope (DSO), sampled data need to be processed after each acquisition. During data processing, the acquisition is stopped and oscilloscope is blind to the input signal. Thus, this duration is called dead time. With the rapid development of modern electronic systems, the effect of infrequent events becomes significant. To capture these occasional events in shorter time, dead time in traditional DSO that causes the loss of measured signal needs to be reduced or even eliminated. In this paper, a seamless acquisition oscilloscope without dead time is proposed. In this oscilloscope, three-dimensional waveform mapping (TWM) technique, which converts sampled data to displayed waveform, is proposed. With this technique, not only the process speed is improved, but also the probability information of waveform is displayed with different brightness. Thus, a three-dimensional waveform is shown to the user. To reduce processing time further, parallel TWM which processes several sampled points simultaneously, and dual-port random access memory based pipelining technique which can process one sampling point in one clock period are proposed. Furthermore, two DDR3 (Double-Data-Rate Three Synchronous Dynamic Random Access Memory) are used for storing sampled data alternately, thus the acquisition can continue during data processing. Therefore, the dead time of DSO is eliminated. In addition, a double-pulse test method is adopted to test the waveform capturing rate (WCR) of the oscilloscope and a combined pulse test method is employed to evaluate the oscilloscope's capture ability comprehensively. The experiment results show that the WCR of the designed oscilloscope is 6 250 000 wfms/s (waveforms per second), the highest value in all existing oscilloscopes. The testing results also prove that there is no dead time in our oscilloscope, thus realizing the seamless acquisition

  4. Synchronization and sequencing of data acquisition and control electronics at the European X-ray free electron laser

    International Nuclear Information System (INIS)

    Gessler, Patrick

    2015-11-01

    The 3.5 km long European X-Ray Free Electron Laser, currently under construction in northern Germany, will deliver bursts of up to 2700 short X-ray pulses every 100 ms, providing wavelengths between 0.05 and 6 nm, and a repetition rate of 4.5 MHz to several experiment stations. It allows in-depth research in various scientific fields. In order to set-up the beam, position samples and capture the measured variables, information from the accelerator, diagnostic devices and detectors have to be digitized, converted, processed, transferred, concentrated, distributed, reorganized, controlled and saved. All these steps have to be accurately synchronized and sequenced relative to the actual electron bunch or photon pulse in order to guarantee correct data acquisition timings and unique identification of each bunch passing the beamlines. This document provides a complete description of the planning, design, realization and evaluation of the European XFEL Timing System, which implements the synchronization and sequencing of the data acquisition and control electronics for the European X-Ray Free-Electron Laser Facility.

  5. Validation of a new HPV self-sampling device for cervical cancer screening: The Cervical and Self-Sample In Screening (CASSIS) study.

    Science.gov (United States)

    El-Zein, Mariam; Bouten, Sheila; Louvanto, Karolina; Gilbert, Lucy; Gotlieb, Walter; Hemmings, Robert; Behr, Marcel A; Franco, Eduardo L; Liang, Victoria; Martins, Claudia; Duarte, Silvy; Sarban, Natalia; Geddes, Patricia; Massa, Ana; Samios, Kathrin; Aboufadl, Siham; Verdon, Sophie; Pereria, Cynthia; Lacroix, Isabelle

    2018-04-17

    We compared the self-sampling performance of the newly designed HerSwab™ device with a physician-collected cervical sample and another self-sample using the cobas® PCR Female swab for the detection of cervical intraepithelial neoplasia (CIN) and cancer. Women referred for colposcopy at McGill University affiliated hospital clinics collected two consecutive self-samples, one with HerSwab™ and one with cobas® swab, after receiving instructions. The order of sampling was randomized. The colposcopist then collected a cervical sample and conducted a colposcopic examination. Samples were tested for human papillomavirus (HPV) DNA. Sensitivity and specificity to detect CIN2+ and respective 95% confidence intervals (CI) were calculated to compare sampling approaches. The HPV testing agreement between samples was measured using the Kappa statistic. Of 1217 women enrolled, 1076 had complete results for HPV and cytology; 148 (13.8%) had CIN1, 147 (13.7%) had CIN2/3, and 5 (0.5%) had cancer. There was very good agreement between methods for HPV detection (HerSwab™ versus physician: kappa=0.84; cobas® swabs versus physician: kappa=0.81; HerSwab™ versus cobas® swabs: kappa=0.87). The sensitivity of HPV detection for CIN2+ was 87.6% (95%CI: 79.8-93.2) with self-sampling using HerSwab™, 88.6% (95%CI: 80.9-94.0) with self-sampling using the cobas® swab, and 92.4% (95%CI: 85.5-96.7) with physician sampling. Corresponding estimates of specificity were 58.1% (95%CI: 54.1-62.1), 55.0% (95%CI: 50.9-59.0) and 58.7% (95%CI: 54.6-62.6). Cytology (ASC-US or more severe) done on the physician-collected specimen was 80.2% (95%CI: 70.8-87.6) sensitive and 61.4% (95%CI: 57.2-65.5) specific for CIN2+. The HerSwab™ had good agreement with physician sampling in detecting HPV, and adequate performance in detecting high-grade lesions among women referred to colposcopy for abnormal cytology. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Simultaneous acquisition of 2D and 3D solid-state NMR experiments for sequential assignment of oriented membrane protein samples

    Energy Technology Data Exchange (ETDEWEB)

    Gopinath, T. [University of Minnesota, Department of Biochemistry, Molecular Biology, and Biophysics (United States); Mote, Kaustubh R. [University of Minnesota, Department of Chemistry (United States); Veglia, Gianluigi, E-mail: vegli001@umn.edu [University of Minnesota, Department of Biochemistry, Molecular Biology, and Biophysics (United States)

    2015-05-15

    We present a new method called DAISY (Dual Acquisition orIented ssNMR spectroScopY) for the simultaneous acquisition of 2D and 3D oriented solid-state NMR experiments for membrane proteins reconstituted in mechanically or magnetically aligned lipid bilayers. DAISY utilizes dual acquisition of sine and cosine dipolar or chemical shift coherences and long living {sup 15}N longitudinal polarization to obtain two multi-dimensional spectra, simultaneously. In these new experiments, the first acquisition gives the polarization inversion spin exchange at the magic angle (PISEMA) or heteronuclear correlation (HETCOR) spectra, the second acquisition gives PISEMA-mixing or HETCOR-mixing spectra, where the mixing element enables inter-residue correlations through {sup 15}N–{sup 15}N homonuclear polarization transfer. The analysis of the two 2D spectra (first and second acquisitions) enables one to distinguish {sup 15}N–{sup 15}N inter-residue correlations for sequential assignment of membrane proteins. DAISY can be implemented in 3D experiments that include the polarization inversion spin exchange at magic angle via I spin coherence (PISEMAI) sequence, as we show for the simultaneous acquisition of 3D PISEMAI–HETCOR and 3D PISEMAI–HETCOR-mixing experiments.

  7. Simultaneous acquisition of 2D and 3D solid-state NMR experiments for sequential assignment of oriented membrane protein samples.

    Science.gov (United States)

    Gopinath, T; Mote, Kaustubh R; Veglia, Gianluigi

    2015-05-01

    We present a new method called DAISY (Dual Acquisition orIented ssNMR spectroScopY) for the simultaneous acquisition of 2D and 3D oriented solid-state NMR experiments for membrane proteins reconstituted in mechanically or magnetically aligned lipid bilayers. DAISY utilizes dual acquisition of sine and cosine dipolar or chemical shift coherences and long living (15)N longitudinal polarization to obtain two multi-dimensional spectra, simultaneously. In these new experiments, the first acquisition gives the polarization inversion spin exchange at the magic angle (PISEMA) or heteronuclear correlation (HETCOR) spectra, the second acquisition gives PISEMA-mixing or HETCOR-mixing spectra, where the mixing element enables inter-residue correlations through (15)N-(15)N homonuclear polarization transfer. The analysis of the two 2D spectra (first and second acquisitions) enables one to distinguish (15)N-(15)N inter-residue correlations for sequential assignment of membrane proteins. DAISY can be implemented in 3D experiments that include the polarization inversion spin exchange at magic angle via I spin coherence (PISEMAI) sequence, as we show for the simultaneous acquisition of 3D PISEMAI-HETCOR and 3D PISEMAI-HETCOR-mixing experiments.

  8. Simultaneous acquisition of 2D and 3D solid-state NMR experiments for sequential assignment of oriented membrane protein samples

    International Nuclear Information System (INIS)

    Gopinath, T.; Mote, Kaustubh R.; Veglia, Gianluigi

    2015-01-01

    We present a new method called DAISY (Dual Acquisition orIented ssNMR spectroScopY) for the simultaneous acquisition of 2D and 3D oriented solid-state NMR experiments for membrane proteins reconstituted in mechanically or magnetically aligned lipid bilayers. DAISY utilizes dual acquisition of sine and cosine dipolar or chemical shift coherences and long living 15 N longitudinal polarization to obtain two multi-dimensional spectra, simultaneously. In these new experiments, the first acquisition gives the polarization inversion spin exchange at the magic angle (PISEMA) or heteronuclear correlation (HETCOR) spectra, the second acquisition gives PISEMA-mixing or HETCOR-mixing spectra, where the mixing element enables inter-residue correlations through 15 N– 15 N homonuclear polarization transfer. The analysis of the two 2D spectra (first and second acquisitions) enables one to distinguish 15 N– 15 N inter-residue correlations for sequential assignment of membrane proteins. DAISY can be implemented in 3D experiments that include the polarization inversion spin exchange at magic angle via I spin coherence (PISEMAI) sequence, as we show for the simultaneous acquisition of 3D PISEMAI–HETCOR and 3D PISEMAI–HETCOR-mixing experiments

  9. Microfluidic Device

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)

    2017-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  10. PlanetVac: Sample Return with a Puff of Gas

    Science.gov (United States)

    Zacny, K.; Mueller, R.; Betts, B. H.

    2014-12-01

    PlanetVac is a regolith sample acquisition mission concept that uses compressed gas to blow material from the surface up a pneumatic tube and directly into a sample return container. The PlanetVac sampling device is built into the lander legs to eliminate cost and complexity associated with robotic arms and scoops. The pneumatic system can effectively capture fine and coarse regolith, including small pebbles. It is well suited for landed missions to Mars, asteroids, or the Moon. Because of the low pressures on all those bodies, the technique is extremely efficient. If losses are kept to minimum, 1 gram of compressed gas could efficiently lift 6000 grams of soil. To demonstrate this approach, the PlanetVac lander with four legs and two sampling tubes has been designed, integrated, and tested. Vacuum chamber testing was performed using two well-known planetary regolith simulants: Mars Mojave Simulant (MMS) and lunar regolith simulant JSC-1A. One of the two sampling systems was connected to a mockup of an earth return rocket while the second sampling system was connected to a lander deck mounted instrument (clear box for easy viewing). The tests included a drop from a height of approximately 50 cm onto the bed of regolith, deployment of sampling tubes into the regolith, pneumatic acquisition of sample into an instrument (sample container) and the rocket, and the launch of the rocket. The demonstration has been successful and can be viewed here: https://www.youtube.com/watch?v=DjJXvtQk6no. In most of the tests, 20 grams or more of sample was delivered to the 'instrument' and approximately 5 grams of regolith was delivered into a sampling chamber within the rocket. The gas lifting efficiency was calculated to be approximately 1000:1; that is 1 gram of gas lofted 1000 grams of regolith. Efficiencies in lower gravity environments are expected to be much higher. This successful, simple and lightweight sample capture demonstration paves the way to using such sampling system

  11. Using Mobile Device Samples to Estimate Traffic Volumes

    Science.gov (United States)

    2017-12-01

    In this project, TTI worked with StreetLight Data to evaluate a beta version of its traffic volume estimates derived from global positioning system (GPS)-based mobile devices. TTI evaluated the accuracy of average annual daily traffic (AADT) volume :...

  12. Antecedents of Cross-Border Acquisition Performance

    DEFF Research Database (Denmark)

    Wang, Daojuan; Moini, Hamid; Kuada, John Ernest

    2017-01-01

    This study investigates the impacts of main implementation activities on the success of cross-border acquisitions (CBAs), using survey data from a sample of 103 CBAs conducted by the companies in Nordic countries. The results of OLS regression analysis indicate that due diligence, integration...

  13. Implementation Issues of Cross-border Acquisitions

    DEFF Research Database (Denmark)

    Wang, Daojuan; Moini, Hamid; Kuada, John

    This study investigates the impacts of main implementation activities on the success of cross-border acquisitions (CBAs) using the survey data from a sample of 103 CBAs conducted by the companies in Scandinavia. The results of regression analysis indicate that due diligence, integration extent...

  14. Speed in Acquisitions

    DEFF Research Database (Denmark)

    Meglio, Olimpia; King, David R.; Risberg, Annette

    2017-01-01

    The advantage of speed is often invoked by academics and practitioners as an essential condition during post-acquisition integration, frequently without consideration of the impact earlier decisions have on acquisition speed. In this article, we examine the role speed plays in acquisitions across...... the acquisition process using research organized around characteristics that display complexity with respect to acquisition speed. We incorporate existing research with a process perspective of acquisitions in order to present trade-offs, and consider the influence of both stakeholders and the pre......-deal-completion context on acquisition speed, as well as the organization’s capabilities to facilitating that speed. Observed trade-offs suggest both that acquisition speed often requires longer planning time before an acquisition and that associated decisions require managerial judgement. A framework for improving...

  15. Image quality assessment of three limited field-of-view cone-beam computed tomography devices in endodontics

    International Nuclear Information System (INIS)

    Tran, Michel

    2015-01-01

    Since the beginning of Cone Beam Computed Tomography (CBCT) in dento-maxillo-facial radiology, many CBCT devices with different technical aspects and characteristics were produced. Technical variations between CBCT and acquisition settings could involve image quality differences. In order to compare the performance of three limited field-of-view CBCT devices, an objective and subjective evaluation of image quality was carried out using an ex-vivo phantom, which combines both diagnostic and technical features. A significant difference in image quality was found between the five acquisition protocols of the study. (author) [fr

  16. Real time acquisition, processing, and archiving of Doublet III diagram data employing table driven software

    International Nuclear Information System (INIS)

    Glad, A.; Henline, P.; Gross, L.; McHarg, B.

    1979-11-01

    This paper describes the diagnostic data acquisition, processing and archiving computer system for the Doublet III fusion research device. This paper's emphasis is mainly on the software, but provides a description of the hardware configuration

  17. On Optimal, Minimal BRDF Sampling for Reflectance Acquisition

    DEFF Research Database (Denmark)

    Nielsen, Jannik Boll; Jensen, Henrik Wann; Ramamoorthi, Ravi

    2015-01-01

    The bidirectional reflectance distribution function (BRDF) is critical for rendering, and accurate material representation requires data-driven reflectance models. However, isotropic BRDFs are 3D functions, and measuring the reflectance of a flat sample can require a million incident and outgoing...... direction pairs, making the use of measured BRDFs impractical. In this paper, we address the problem of reconstructing a measured BRDF from a limited number of samples. We present a novel mapping of the BRDF space, allowing for extraction of descriptive principal components from measured databases......, such as the MERL BRDF database. We optimize for the best sampling directions, and explicitly provide the optimal set of incident and outgoing directions in the Rusinkiewicz parameterization for n = {1, 2, 5, 10, 20} samples. Based on the principal components, we describe a method for accurately reconstructing BRDF...

  18. Impact of Merger and Acquisition on University Performance.

    Science.gov (United States)

    Mohamadi Bolbanabad, Amjad; Mosadeghrad, Ali Mohammad; Arab, Mohammad; Majdzadeh, Reza

    2017-08-01

    Merger and acquisitions (M&A) widen access to higher education, improve quality of teaching and research, and increase efficiency of higher education institutions. Three big medical universities in Iran merged in 2010. The purpose of this study was to highlight the impact of this acquisition on the performance of Tehran University of Medical Sciences. This qualitative study was conducted using semi-structured in-depth interviews with 60 participants from April 2015 to November 2015. Purposeful sampling was used to recruit participants. Data analysis was performed using MAXQDA software (V. 10). The reasons for acquisition of IUMS by TUMS were to enhance the position of TUMS worldwide, and to increase its efficiency. The acquisition improved the organization and management of the newly formed TUMS, enhanced its academic position and market recognition. However, the achieved benefits did not come without shortcomings and unanticipated consequences. The merger and acquisition in higher education has some advantages and disadvantages. A well planned and carefully implemented M&A gives cutting edge to the higher education institutes.

  19. Microprocessor system for data acquisition processing and display for Auger electrons spectrometer

    International Nuclear Information System (INIS)

    Pawlowski, Z.; Cudny, W.; Hildebrandt, S.; Marzec, J.; Walentek, J.; Zaremba, K.

    1984-01-01

    Data acquisition system for Auger electron spectrometry is developed. The system is used for chemical and structural analysis of materials and consists of a cylindrical mirror analyzer being a measuring spectrometer device, CAMAC unit and control unit. The control unit comprises a microcomputer based on INTEL 8080 microprocessor and display

  20. Development and Integration of a Data Acquisition System for SST-1 Phase-1 Plasma Diagnostics

    International Nuclear Information System (INIS)

    Srivastava, Amit K; Sharma, Manika; Mansuri, Imran; Sharma, Atish; Raval, Tushar; Pradhan, Subrata

    2012-01-01

    Long pulse (of the order of 1000 s or more) SST-1 tokamak experiments demand a data acquisition system that is capable of acquiring data from various diagnostics channels without losing useful data (and hence physics information) while avoiding unnecessary generation of a large volume data. SST-1 Phase-1 tokamak operation has been envisaged with data acquisition of several essential diagnostics channels. These channels demand data acquisition at a sampling rate ranging from 1 kilo samples per second (KSPS) to 1 mega samples per second (MSPS). Considering the technical characteristics and requirements of the diagnostics, a data acquisition system based on PXI and CAMAC has been developed for SST-1 plasma diagnostics. Both these data acquisition systems are scalable. Present data acquisition needs involving slow plasma diagnostics are catered by the PXI based data acquisition system. On the other hand, CAMAC data acquisition hardware meets all requirements of the SST-1 Phase-1 fast plasma diagnostics channels. A graphical user interface for both data acquisition systems (PXI and CAMAC) has been developed using LabVIEW application development software. The collected data on the local hard disk are directly streaming to the central server through a dedicated network for post-shot data analysis. This paper describes the development and integration of the data acquisition system for SST-1 Phase-1 plasma diagnostics. The integrated testing of the developed data acquisition system has been performed using SST-1 central control and diagnostics signal conditioning units. In the absence of plasma shots, the integrated testing of the data acquisition system for the initial diagnostics of SST-1 Phase-1 operation has been performed with simulated physical signals. The primary engineering objective of this integrated testing is to validate the performance of the developed data acquisition system under simulated conditions close to that of actual tokamak operation. The data

  1. Device localization and dynamic scan plane selection using a wireless MRI detector array

    Science.gov (United States)

    Riffe, Matthew J.; Yutzy, Stephen R.; Jiang, Yun; Twieg, Michael D.; Blumenthal, Colin J.; Hsu, Daniel P.; Pan, Li; Gilson, Wesley D.; Sunshine, Jeffrey L.; Flask, Christopher A.; Duerk, Jeffrey L.; Nakamoto, Dean; Gulani, Vikas; Griswold, Mark A.

    2013-01-01

    Purpose A prototype wireless guidance device using single sideband amplitude modulation (SSB) is presented for a 1.5T MRI system. Methods The device contained three fiducial markers each mounted to an independent receiver coil equipped with wireless SSB technology. Acquiring orthogonal projections of these markers determined the position and orientation of the device, which was used to define the scan plane for a subsequent image acquisition. Device localization and scan plane update required approximately 30 ms, so it could be interleaved with high temporal resolution imaging. Since the wireless device is used for localization and doesn’t require full imaging capability, the design of the SSB wireless system was simplified by allowing an asynchronous clock between the transmitter and receiver. Results When coupled to a high readout bandwidth, the error caused by the lack of a shared frequency reference was quantified to be less than one pixel (0.78 mm) in the projection acquisitions. Image-guidance with the prototype was demonstrated with a phantom where a needle was successfully guided to a target and contrast was delivered. Conclusion The feasibility of active tracking with a wireless detector array is demonstrated. Wireless arrays could be incorporated into devices to assist in image-guided procedures. PMID:23900921

  2. Synergy disclosures in mergers and acquisitions

    NARCIS (Netherlands)

    M.D.R.P. Dutordoir (Marie); P.G.J. Roosenboom (Peter); M. Teixeira de Vasconcelos (Manuel)

    2013-01-01

    textabstractWe examine bidding firms’ motives for disclosing a synergy forecast when announcing a merger or acquisition. Our sample consists of 1,990 M&A deals, of which 345 announce synergy estimates. Our results suggest that synergy disclosures serve to obtain a more favorable market reception for

  3. WiFi Data Acquisition System Applied to a Photovoltaic Powered Water Pumping Plant

    Directory of Open Access Journals (Sweden)

    Sandro César Silveira JUCÁ

    2015-02-01

    Full Text Available The present paper describes how to design and assemble a low cost online monitoring and WiFi data acquisition system using free software applied to microgeneration based on renewable energy sources. The development of online monitoring systems for microgeneration plants based on renewable energy sources is becoming more important, considering that monitoring and data acquisition systems are applicable in stages of the microgeneration process. The monitoring and data acquisition WiFi system was developed using an embedded WiFi modem (Wifly coupled to a microcontrolled board based on the free tool SanUSB. This monitoring system was applied to a photovoltaic (PV water pumping plant without batteries, so as the control system and the wireless communication with the online server, which is also autonomous and powered by PV panel. The free software for online monitoring and WiFi data acquisition allows the analysis of stored data and charts through mobile devices as notebooks, tablets and smartphones.

  4. The data acquisition system for SLD

    International Nuclear Information System (INIS)

    Sherden, D.J.

    1986-10-01

    This paper describes the data acquisition system planned for the SLD detector, which is being constructed for use with the SLAC Linear Collider (SLC). Analog electronics, heavily incorporating hybrid and custom VLSI circuitry, is mounted on the detector itself. Extensive use is made of multiplexing through optical fibers to a FASTBUS readout system. The low repetition rate of the SLC allows a relatively simple software-based trigger. Hardware and software processors within the acquisition modules are used to reduce the large volume of data per event and to calibrate the electronics. A farm of microprocessors is used for full reconstruction of a sample of events prior to transmission to the host

  5. Due Diligence Processes for Public Acquisition of Mining-Impacted Landscapes

    Science.gov (United States)

    Martin, E.; Monohan, C.; Keeble-Toll, A. K.

    2016-12-01

    The acquisition of public land is critical for achieving conservation and habitat goals in rural regions projected to experience continuously high rates of population growth. To ensure that public funds are utilized responsibly in the purchase of conservation easements appropriate due diligence processes must be established that limit landowner liability post-acquisition. Traditional methods of characterizing contamination in regions where legacy mining activities were prevalent may not utilize current scientific knowledge and understanding of contaminant fate, transport and bioavailability, and therefore are likely to have type two error. Agency prescribed assessment methods utilized under CERLA in many cases fail to detect contamination that presents liability issues by failing to require water quality sampling that would reveal offsite transport potential of contaminants posing human health risks, including mercury. Historical analysis can be used to inform judgmental sampling to identify hotspots and contaminants of concern. Land acquisition projects at two historic mine sites in Nevada County, California, the Champion Mine Complex and the Black Swan Preserve have established the necessity of re-thinking due diligence processes for mining-impacted landscapes. These pilot projects demonstrate that pre-acquisition assessment in the Gold Country must include judgmental sampling and evaluation of contaminant transport. Best practices using the current scientific knowledge must be codified by agencies, consultants, and NGOs in order to ensure responsible use of public funds and to safeguard public health.

  6. Does frequency count? Parental input and the acquisition of vocabulary.

    Science.gov (United States)

    Goodman, Judith C; Dale, Philip S; Li, Ping

    2008-08-01

    Studies examining factors that influence when words are learned typically investigate one lexical category or a small set of words. We provide the first evaluation of the relation between input frequency and age of acquisition for a large sample of words. The MacArthur-Bates Communicative Development Inventory provides norming data on age of acquisition for 562 individual words collected from the parents of children aged 0 ; 8 to 2 ; 6. The CHILDES database provides estimates of frequency with which parents use these words with their children (age: 0 ; 7-7 ; 5; mean age: 36 months). For production, across all words higher parental frequency is associated with later acquisition. Within lexical categories, however, higher frequency is related to earlier acquisition. For comprehension, parental frequency correlates significantly with the age of acquisition only for common nouns. Frequency effects change with development. Thus, frequency impacts vocabulary acquisition in a complex interaction with category, modality and developmental stage.

  7. Data acquisition and control of the 370 TBq high-pressure tritium doping device, TRIBA

    International Nuclear Information System (INIS)

    Pfeil, A.; Heer, H.; Laesser, R.; Klatt, K.H.

    1987-07-01

    The report is arranged as follows: After an introduction, the first section briefly discusses measured values obtained with the 37 TBq (10 3 Ci) doping device with a view to the enhanced measuring range that is achievable with the newly developed 370 TBq (10 4 Ci) device. Sections 3 and 4 explain the technical design of the device and the measuring and control equipment connected to the computer. All following sections are detailed descriptions of the computer configuration and the software. (orig./HP) [de

  8. Unit 06 - Sampling the World

    OpenAIRE

    Unit 06, CC in GIS; Parson, Charles; Nyerges, Timothy

    1990-01-01

    This unit begins the section on data acquisition by looking at how the infinite complexity of the real world can be discretized and sampled. It considers sampling techniques and associated issues of accuracy and standards.

  9. Experiment of laser thomson scattering at HL-1 tokamak device

    International Nuclear Information System (INIS)

    Zuo Henian; Chen Jiafu; Yan Derong; Liu Aiping; Shi Peilan; Wang Wei; Liu Xiaomei

    1989-05-01

    The structure and performance of the Ruby Laser Thomson Scattering apparatus for HL-1 tokamak device is described. The method of acquisition and calibration of multichannel scattered signals are presented. Examples of measured electron temperature T. with experimental error are given

  10. Resource Complementarity and Value Capture in Firm Acquisitions

    DEFF Research Database (Denmark)

    Grimpe, Christoph; Hussinger, Katrin

    2014-01-01

    exclusion and freedom to operate in R&D. We argue that such property rights hold preemptive power allowing firms to capture the value from combining complementary technologies and to realize gains from trade in strategic factor markets. Our results for a sample of 1,428 acquisitions indicate that......—controlling for technological value—acquired preemptive power is an important determinant of the acquisition price, particularly when the acquirer is technology intensive and acquired patents are highly related to the acquirer's knowledge base....

  11. Failed fuel detection device

    International Nuclear Information System (INIS)

    Doi, Akira.

    1994-01-01

    The device of the present invention concerns a failed fuel detection device for a nuclear reactor, such as an FBR type reactor, using electroconductive coolants. A sampling port is disposed at the upper portion of the fuel assembly so as to cover the assembly, so that coolants in the fuel assembly are sampled to improve a device for detecting fuel failure. That is, when coolants in the fuel assembly are sampled from the sampling port, the flow of electroconductive coolants in an sampling tube is detected by a flowmeter, to control an electromagnetic pump. The flow of electroconductive coolants is stopped against the waterhead pressure and dynamic pressure of the conductive coolants, and a predetermined amount of the coolants is pumped up to the sampling tank. Gas is supplied to the pumped up coolants so that fissile products are transferred from the coolants to a gas phase. Radiation in the gas in a gas recycling system is measured to detect presence of fuel failure. (I.S.)

  12. Devices, Distractions and Digital Literacy: "Bring Your Own Device" to Polytech

    Science.gov (United States)

    Drew, Leoni; Forbes, Dianne

    2017-01-01

    The purpose of this study is to investigate the ways polytechnic students use personal mobile devices to support their learning. This study used purposive sampling and mixed methods to generate data about student ownership and use of mobile digital devices within a single institution. Findings reveal patterns of device ownership, insights into how…

  13. Use of wearable devices for post-discharge monitoring of ICU patients: a feasibility study

    Directory of Open Access Journals (Sweden)

    Ryan R. Kroll

    2017-11-01

    Full Text Available Abstract Background Wearable devices generate signals detecting activity, sleep, and heart rate, all of which could enable detailed and near-continuous characterization of recovery following critical illness. Methods To determine the feasibility of using a wrist-worn personal fitness tracker among patients recovering from critical illness, we conducted a prospective observational study of a convenience sample of 50 stable ICU patients. We assessed device wearability, the extent of data capture, sensitivity and specificity for detecting heart rate excursions, and correlations with questionnaire-derived sleep quality measures. Results Wearable devices were worn over a 24-h period, with excellent capture of data. While specificity for the detection of tachycardia was high (98.8%, sensitivity was low to moderate (69.5%. There was a moderate correlation between wearable-derived sleep duration and questionnaire-derived sleep quality (r = 0.33, P = 0.03. Devices were well-tolerated and demonstrated no degradation in quality of data acquisition over time. Conclusions We found that wearable devices could be worn by patients recovering from critical illness and could generate useful data for the majority of patients with little adverse effect. Further development and study are needed to better define and enhance the role of wearables in the monitoring of post-ICU recovery. Trial registration Clinicaltrials.gov, NCT02527408

  14. Development and validation of a smartphone heart rate acquisition application for health promotion and wellness telehealth applications.

    Science.gov (United States)

    Gregoski, Mathew J; Mueller, Martina; Vertegel, Alexey; Shaporev, Aleksey; Jackson, Brenda B; Frenzel, Ronja M; Sprehn, Sara M; Treiber, Frank A

    2012-01-01

    Objective. Current generation smartphones' video camera technologies enable photoplethysmographic (PPG) acquisition and heart rate (HR) measurement. The study objective was to develop an Android application and compare HRs derived from a Motorola Droid to electrocardiograph (ECG) and Nonin 9560BT pulse oximeter readings during various movement-free tasks. Materials and Methods. HRs were collected simultaneously from 14 subjects, ages 20 to 58, healthy or with clinical conditions, using the 3 devices during 5-minute periods while at rest, reading aloud under observation, and playing a video game. Correlation between the 3 devices was determined, and Bland-Altman plots for all possible pairs of devices across all conditions assessed agreement. Results. Across conditions, all device pairs showed high correlations. Bland-Altman plots further revealed the Droid as a valid measure for HR acquisition. Across all conditions, the Droid compared to ECG, 95% of the data points (differences between devices) fell within the limits of agreement. Conclusion. The Android application provides valid HRs at varying levels of movement free mental/perceptual motor exertion. Lack of electrode patches or wireless sensor telemetric straps make it advantageous for use in mobile-cell-phone-delivered health promotion and wellness programs. Further validation is needed to determine its applicability while engaging in physical movement-related activities.

  15. Development and Validation of a Smartphone Heart Rate Acquisition Application for Health Promotion and Wellness Telehealth Applications

    Directory of Open Access Journals (Sweden)

    Mathew J. Gregoski

    2012-01-01

    Full Text Available Objective. Current generation smartphones' video camera technologies enable photoplethysmographic (PPG acquisition and heart rate (HR measurement. The study objective was to develop an Android application and compare HRs derived from a Motorola Droid to electrocardiograph (ECG and Nonin 9560BT pulse oximeter readings during various movement-free tasks. Materials and Methods. HRs were collected simultaneously from 14 subjects, ages 20 to 58, healthy or with clinical conditions, using the 3 devices during 5-minute periods while at rest, reading aloud under observation, and playing a video game. Correlation between the 3 devices was determined, and Bland-Altman plots for all possible pairs of devices across all conditions assessed agreement. Results. Across conditions, all device pairs showed high correlations. Bland-Altman plots further revealed the Droid as a valid measure for HR acquisition. Across all conditions, the Droid compared to ECG, 95% of the data points (differences between devices fell within the limits of agreement. Conclusion. The Android application provides valid HRs at varying levels of movement free mental/perceptual motor exertion. Lack of electrode patches or wireless sensor telemetric straps make it advantageous for use in mobile-cell-phone-delivered health promotion and wellness programs. Further validation is needed to determine its applicability while engaging in physical movement-related activities.

  16. Non-contact wearable single forearm cardiac biopotential acquisition device

    International Nuclear Information System (INIS)

    Gonçalves, Sérgio; Martins, Raul Carneiro

    2013-01-01

    In this work the authors propose a novel approach to obtain the electrocardiogram in the forearm using non-contact sensing. This new solution should be at same time portable, ergonomic and robust, enabling its use in different set of applications. A system of four electrodes was used in an adjustable sleeve to be wrapped in the forearm. No additional electrode references were used in other body parts. In order to increase the sensitivity of the system, an harmonium like approach was used in the design of the electrodes. The prototype was then compared with a similar system with a flat conformation. The developed prototype enabled the acquisition of an ECG signal in the forearm and the inclusion of the harmonium like electrode conformation resulted in a considerable increase of the sensitivity of the system. The acquired signal did not enable the identification of all characteristic cardiac waves. However, it was possible to identify clearly a signal pattern, characteristic of the QRS complex. The properties of the acquired signal restrict their use in rigorous electrocardiographic studies, allowing, however, its application in heart rate variability monitoring and biometric identification without the disadvantages usually associated with conventional electrodes. This makes it specially useful for man-machine interfaces and automated identification

  17. Upgrading of data acquisition software for centralized radiation monitoring system in Malaysian Nuclear Agency

    Energy Technology Data Exchange (ETDEWEB)

    Yussup, F., E-mail: nolida@nm.gov.my; Ibrahim, M. M., E-mail: maslina-i@nm.gov.my; Soh, S. C.; Hasim, H. [Instrumentation and Automation Centre, Technical Support Division, Malaysian Nuclear Agency, Bangi, 43000 Kajang. Selangor (Malaysia); Haris, M. F. [Information Technology Centre, Technical Support Division, Malaysian Nuclear Agency, Bangi, 43000 Kajang. Selangor (Malaysia); Azman, A. [Prototype and Development Centre, Technical Support Division, Malaysian Nuclear Agency, Bangi, 43000 Kajang. Selangor (Malaysia); Razalim, F. A. A.; Yapp, R. [Health Physics Group, Radiation Safety and Health Division, Malaysian Nuclear Agency, Bangi, 43000 Kajang. Selangor (Malaysia); Ramli, A. A. M. [Technical Support Division, Malaysian Nuclear Agency, Bangi, 43000 Kajang. Selangor (Malaysia)

    2016-01-22

    With the growth of technology, many devices and equipments can be connected to the network and internet to enable online data acquisition for real-time data monitoring and control from monitoring devices located at remote sites. Centralized radiation monitoring system (CRMS) is a system that enables area radiation level at various locations in Malaysian Nuclear Agency (Nuklear Malaysia) to be monitored centrally by using a web browser. The Local Area Network (LAN) in Nuclear Malaysia is utilized in CRMS as a communication media for data acquisition of the area radiation levels from radiation detectors. The development of the system involves device configuration, wiring, network and hardware installation, software and web development. This paper describes the software upgrading on the system server that is responsible to acquire and record the area radiation readings from the detectors. The recorded readings are called in a web programming to be displayed on a website. Besides the main feature which is acquiring the area radiation levels in Nuclear Malaysia centrally, the upgrading involves new features such as uniform time interval for data recording and exporting, warning system and dose triggering.

  18. Upgrading of data acquisition software for centralized radiation monitoring system in Malaysian Nuclear Agency

    International Nuclear Information System (INIS)

    Yussup, F.; Ibrahim, M. M.; Soh, S. C.; Hasim, H.; Haris, M. F.; Azman, A.; Razalim, F. A. A.; Yapp, R.; Ramli, A. A. M.

    2016-01-01

    With the growth of technology, many devices and equipments can be connected to the network and internet to enable online data acquisition for real-time data monitoring and control from monitoring devices located at remote sites. Centralized radiation monitoring system (CRMS) is a system that enables area radiation level at various locations in Malaysian Nuclear Agency (Nuklear Malaysia) to be monitored centrally by using a web browser. The Local Area Network (LAN) in Nuclear Malaysia is utilized in CRMS as a communication media for data acquisition of the area radiation levels from radiation detectors. The development of the system involves device configuration, wiring, network and hardware installation, software and web development. This paper describes the software upgrading on the system server that is responsible to acquire and record the area radiation readings from the detectors. The recorded readings are called in a web programming to be displayed on a website. Besides the main feature which is acquiring the area radiation levels in Nuclear Malaysia centrally, the upgrading involves new features such as uniform time interval for data recording and exporting, warning system and dose triggering

  19. Development and implementation of real-time data acquisition systems for fusion devices with Open Source software

    International Nuclear Information System (INIS)

    Zilker, M.; Behler, K.; Bluhm, T.; Heimann, P.; Hennig, Ch.; Kroiss, H.; Kuehner, G.; Laqua, H.; Lewerentz, M.; Maier, J.; Neu, G.; Raupp, G.; Reich, M.; Riemann, H.; Schacht, J.; Spring, A.; Treutterer, W.; Werner, A.; Zehetbauer, T.

    2010-01-01

    To improve the plasma position and shape control system in ASDEX Upgrade, it is constantly expanded by the integration of data acquisition systems of important and interesting diagnostics. Usually the main responsibility of data acquisition systems is to collect data and subsequently put it into a data base archive system from where it is later analysed. The obligation now is also to simultaneously process the acquired data with an appropriate algorithm and send the pre-processed data in real-time to the plasma control system during a discharge. To achieve this requirements the used hardware must provide enough processing power and the operating system has to meet some real-time constraints. To avoid the burden of using proprietary real-time operating systems the trend is to use Open Source variants mainly based on Linux. Some of these solutions also allow us doing real-time capable communication using standard Ethernet hardware. By way of an example the implementation process of a prototype of a real-time data acquisition system based on a multi-core processor and Xenomai is demonstrated. Other possible solutions like Realtime Linux and their differences to Xenomai which we propose as the most sophisticated real-time framework for Linux are discussed in this paper.

  20. The Classification of Tongue Colors with Standardized Acquisition and ICC Profile Correction in Traditional Chinese Medicine.

    Science.gov (United States)

    Qi, Zhen; Tu, Li-Ping; Chen, Jing-Bo; Hu, Xiao-Juan; Xu, Jia-Tuo; Zhang, Zhi-Feng

    2016-01-01

    Background and Goal . The application of digital image processing techniques and machine learning methods in tongue image classification in Traditional Chinese Medicine (TCM) has been widely studied nowadays. However, it is difficult for the outcomes to generalize because of lack of color reproducibility and image standardization. Our study aims at the exploration of tongue colors classification with a standardized tongue image acquisition process and color correction. Methods . Three traditional Chinese medical experts are chosen to identify the selected tongue pictures taken by the TDA-1 tongue imaging device in TIFF format through ICC profile correction. Then we compare the mean value of L * a * b * of different tongue colors and evaluate the effect of the tongue color classification by machine learning methods. Results . The L * a * b * values of the five tongue colors are statistically different. Random forest method has a better performance than SVM in classification. SMOTE algorithm can increase classification accuracy by solving the imbalance of the varied color samples. Conclusions . At the premise of standardized tongue acquisition and color reproduction, preliminary objectification of tongue color classification in Traditional Chinese Medicine (TCM) is feasible.

  1. Development of Hand Grip Assistive Device Control System for Old People through Electromyography (EMG Signal Acquisitions

    Directory of Open Access Journals (Sweden)

    Khamis Herman

    2017-01-01

    Full Text Available The hand grip assistive device is a glove to assist old people who suffer from hand weakness in their daily life activities. The device earlier control system only use simple on and off switch. This required old people to use both hand to activate the device. The new control system of the hand grip assistive device was developed to allow single hand operation for old people. New control system take advantages of electromyography (EMG and flex sensor which was implemented to the device. It was programmed into active and semi-active mode operation. EMG sensors were placed on the forearm to capture EMG signal of Flexor Digitorum Profundus muscle to activate the device. Flex sensor was used to indicate the finger position and placed on top of the finger. The signal from both sensors then used to control the device. The new control system allowed single hand operation and designed to prevent user from over depended on the device by activating it through moving their fingers.

  2. FireSignal-Data acquisition and control system software

    Energy Technology Data Exchange (ETDEWEB)

    Neto, A. [Associacao Euratom/IST, Centro de Fusao Nuclear, Av. Rovisco Pais, P-1049-001 Lisboa (Portugal)], E-mail: andre.neto@cfn.ist.utl.pt; Fernandes, H.; Duarte, A.; Carvalho, B.B.; Sousa, J.; Valcarcel, D.F. [Associacao Euratom/IST, Centro de Fusao Nuclear, Av. Rovisco Pais, P-1049-001 Lisboa (Portugal); Hron, M. [Asociace EURATOM IPP.CR, Prague (Czech Republic); Varandas, C.A.F. [Associacao Euratom/IST, Centro de Fusao Nuclear, Av. Rovisco Pais, P-1049-001 Lisboa (Portugal)

    2007-10-15

    Control of fusion experiments requires non-ambiguous, easy to use, user-interfaces to configure hardware devices. With that aim, a highly generic system for data control and acquisition has been developed. Among the main features it allows remote hardware configuration, shot launching, data sharing between connected users and experiment monitoring. The system is fully distributed: the hardware driver nodes, clients and servers are completely independent from each other and might run in different operating systems and programmed in different languages. All the communication is provided through the Common Object Request Broker Architecture (CORBA) protocol. FireSignal is designed to be as independent as possible from any kind of constraints as it is a plugin based system. Database, data viewers and the security system are some examples of what can easily be changed and adapted to the target machine's needs. In this system, every hardware is described in eXtensible Markup Language (XML) and with this information Graphical User Interfaces (GUI) are automatically built and user's parameter configuration validated. Any type of hardware device can be integrated in the system as long as it is described in XML and the respective driver developed. Any modern programming language can be used to develop these drivers. Currently Python and Java generic drivers are used. Data storage and indexing is time stamp event-based. Nodes are responsible for tagging the acquired samples with the absolute time stamps and to react to machine events. FireSignal is currently being used to control the ISTTOK/PT and CASTOR/CZ tokamaks.

  3. FireSignal-Data acquisition and control system software

    International Nuclear Information System (INIS)

    Neto, A.; Fernandes, H.; Duarte, A.; Carvalho, B.B.; Sousa, J.; Valcarcel, D.F.; Hron, M.; Varandas, C.A.F.

    2007-01-01

    Control of fusion experiments requires non-ambiguous, easy to use, user-interfaces to configure hardware devices. With that aim, a highly generic system for data control and acquisition has been developed. Among the main features it allows remote hardware configuration, shot launching, data sharing between connected users and experiment monitoring. The system is fully distributed: the hardware driver nodes, clients and servers are completely independent from each other and might run in different operating systems and programmed in different languages. All the communication is provided through the Common Object Request Broker Architecture (CORBA) protocol. FireSignal is designed to be as independent as possible from any kind of constraints as it is a plugin based system. Database, data viewers and the security system are some examples of what can easily be changed and adapted to the target machine's needs. In this system, every hardware is described in eXtensible Markup Language (XML) and with this information Graphical User Interfaces (GUI) are automatically built and user's parameter configuration validated. Any type of hardware device can be integrated in the system as long as it is described in XML and the respective driver developed. Any modern programming language can be used to develop these drivers. Currently Python and Java generic drivers are used. Data storage and indexing is time stamp event-based. Nodes are responsible for tagging the acquired samples with the absolute time stamps and to react to machine events. FireSignal is currently being used to control the ISTTOK/PT and CASTOR/CZ tokamaks

  4. WIRELESS DISTRIBUTED ACQUISITION SYSTEM FOR NEAR INFRARED SPECTROSCOPY – WDA-NIRS

    Directory of Open Access Journals (Sweden)

    J. SAFAIE

    2013-07-01

    Full Text Available The wireless distributed acquisition system for near infrared spectroscopy (WDA-NIRS is a portable, ultra-compact, continuous wave (CW NIRS system. Its main advantage is that it allows continuous synchronized multi-site hemodynamic monitoring. The WDA-NIRS system calculates online changes in hemoglobin concentration based on modified Beer–Lambert law and the tissue oxygenation index based on the spatial-resolved spectroscopy method. It consists of up to seven signal acquisition units, sufficiently small to be easily attached to any part of the body. These units are remotely synchronized by a PC base station for independent acquisition of NIRS signals. Each acquisition module can be freely adapted to individual requirements such as local skin properties and the microcirculation of interest, e.g., different muscles, brain, skin, etc. For this purpose, the light emitted by each LED can be individually, interactively or automatically adjusted to local needs. Furthermore, the user can freely create an emitter time-multiplexing protocol and choose the detector sensitivity most suitable to a particular situation. The potential diagnostic value of this advanced device is demonstrated by three typical applications.

  5. Data acquisition and control system for SMARTEX – C

    Energy Technology Data Exchange (ETDEWEB)

    Yeole, Yogesh Govind, E-mail: yogesh@ipr.res.in [Institute for Plasma Research, Gandhinagar, 382 428 Gujarat (India); Lachhvani, Lavkesh; Bajpai, Manu; Rathod, Surendrasingh; Kumar, Abhijeet; Sathyanarayana, K.; Pujara, H.D. [Institute for Plasma Research, Gandhinagar, 382 428 Gujarat (India); Pahari, Sambaran [BARC, Vishakhapatanam, 530 012 Andhra Pradesh (India); Chattopadhyay, Prabal K. [Institute for Plasma Research, Gandhinagar, 382 428 Gujarat (India)

    2016-11-15

    Highlights: • We have developed control and data acquisition system for Nonneutral Plasma experiment named as SMARTEX – C. • The hardware of the system includes a high current power supply, a trigger circuit, a comparator circuit, a PXI system and a computer. • The software has been developed in LabVIEW{sup ®}. • We have presented the complete time synchronization of the operation of the system. • Results obtained from the equipment has been shown. - Abstract: A PXI based data acquisition system has been developed for Small Aspect Ratio Toroidal Experiment in C – shaped geometry (SMARTEX – C), a device to create and confine non-neutral plasma. The data acquisition system (DAQ) includes PXI based data acquisition cards, communication card, chassis, Optical fiber link, a dedicated computer, a trigger circuit (TC) and a voltage comparator. In this paper, we report the development of a comprehensive code in LabVIEW{sup ®} – 2012 software in order to control the operation of SMARTEX – C as well as to acquire the experimental data from it. The code has been incorporated with features like configuration of card parameters. A hardware based control sequence involving TC has also been developed and integrated with the DAQ. In the acquisition part, the data from an experimental shot is acquired when a digital pulse from one of the PXI cards triggers TC, which further triggers the TF – power supply and rest of the DAQ. The data hence acquired, is stored in the hard disc in binary format for further analysis.

  6. Development of Hand Grip Assistive Device Control System for Old People through Electromyography (EMG) Signal Acquisitions

    OpenAIRE

    Khamis Herman; Mohamaddan Shahrol; Komeda Takashi; Alias Aidil Azli; Tanjong Shirley Jonathan; Julai Norhuzaimin; Hashim Nurul ‘Izzati

    2017-01-01

    The hand grip assistive device is a glove to assist old people who suffer from hand weakness in their daily life activities. The device earlier control system only use simple on and off switch. This required old people to use both hand to activate the device. The new control system of the hand grip assistive device was developed to allow single hand operation for old people. New control system take advantages of electromyography (EMG) and flex sensor which was implemented to the device. It wa...

  7. A DSP controlled data acquisition system for CELSIUS

    International Nuclear Information System (INIS)

    Bengtsson, M.; Lofnes, T.; Ziemann, V.

    2000-01-01

    We describe a data acquisition system based on two 10 MHz A/D-converters, a SHARC Digital Signal Processor (DSP), and a digital synthesizer used for triggering the A/D-converters. The temporal macrostructure of the data acquisition can be determined by external triggers or by timer interrupts from the DSP. In this way up to two million samples can be stored in DSP external memory. The samples are analyzed by directly fast Fourier transforming blocks of samples. In another mode we use software-based downmixing and filtering techniques to increase the resolution and zoom in on a small frequency band. Spectra of up to 5 MHz can be manipulated and displayed as waterfall plots or spectral maps on the host computer directly. Moreover, signals of up to 70 MHz can be analyzed by undersampling techniques. We use this system to analyze Schottky spectra from electron-cooled ion beams in CELSIUS and report drag rate measurements and observations of instabilities

  8. A DSP controlled data acquisition system for CELSIUS

    CERN Document Server

    Bengtsson, M; Ziemann, Volker

    2000-01-01

    We describe a data acquisition system based on two 10 MHz A/D-converters, a SHARC Digital Signal Processor (DSP), and a digital synthesizer used for triggering the A/D-converters. The temporal macrostructure of the data acquisition can be determined by external triggers or by timer interrupts from the DSP. In this way up to two million samples can be stored in DSP external memory. The samples are analyzed by directly fast Fourier transforming blocks of samples. In another mode we use software-based downmixing and filtering techniques to increase the resolution and zoom in on a small frequency band. Spectra of up to 5 MHz can be manipulated and displayed as waterfall plots or spectral maps on the host computer directly. Moreover, signals of up to 70 MHz can be analyzed by undersampling techniques. We use this system to analyze Schottky spectra from electron-cooled ion beams in CELSIUS and report drag rate measurements and observations of instabilities.

  9. An embedded point-of-care malaria screening device for low-resource regions (Conference Presentation)

    Science.gov (United States)

    Das, Sayantan; Mandal, Subhamoy; Das, Debnath; Malviya, Richa; Garud, Hrushikesh T.; Ray, Ajoy K.

    2016-03-01

    In this article we propose a point-of-care screening device for the detection and identification of malaria parasite, plasmodium vivax, plasmodium malaria, plasmodium oval and plasmodium falciparum with a time frame of 15-20 minute. In our device we can provide 97-98% sensitivity for each species as we are using traditional staining methods for detecting the parasites. In addition, as we are also quantifying the parasites, it is possible to provide an accurate estimate about the malarial stage of the patient. The image processing approach increases the total numbers of samples screened by reducing interventions of trained pathologists. This helps in reducing the delays in screening process arising from increased number of potential cases based on seasonal and local variations. The same reduces mortality rate by faster diagnosis and reduced false negative detections (i.e. increased sensitivity). The system can also be integrated with telemedicine platform to obtain inputs from medical practitioners at tertiary healthcare units for diagnostic decision making. Through this paper, we present the functional prototype of this device containing all the integrated parts. The prototype incorporates image acquisition, image processing, storage, multimedia transmission and reporting environment for a low cost PDA device. It is a portable device capable of scanning slides. The acquired image will be preprocessed and processed to get desired output. The device is capable of transmitting and storing pathological information to database placed in a distant pathological center for further consultation.

  10. Use of a holder-vacuum tube device to save on-site hands in preparing urine samples for head-space gas-chromatography, and its application to determine the time allowance for sample sealing.

    Science.gov (United States)

    Kawai, Toshio; Sumino, Kimiaki; Ohashi, Fumiko; Ikeda, Masayuki

    2011-01-01

    To facilitate urine sample preparation prior to head-space gas-chromatographic (HS-GC) analysis. Urine samples containing one of the five solvents (acetone, methanol, methyl ethyl ketone, methyl isobutyl ketone and toluene) at the levels of biological exposure limits were aspirated into a vacuum tube via holder, a device commercially available for venous blood collection (the vacuum tube method). The urine sample, 5 ml, was quantitatively transferred to a 20-ml head-space vial prior to HS-GC analysis. The loaded tubes were stored at +4 ℃ in dark for up to 3 d. The vacuum tube method facilitated on-site procedures of urine sample preparation for HS-GC with no significant loss of solvents in the sample and no need of skilled hands, whereas on-site sample preparation time was significantly reduced. Furthermore, no loss of solvents was detected during the 3-d storage, irrespective of hydrophilic (acetone) or lipophilic solvent (toluene). In a pilot application, high performance of the vacuum tube method in sealing a sample in an air-tight space succeeded to confirm that no solvent will be lost when sealing is completed within 5 min after urine voiding, and that the allowance time is as long as 30 min in case of toluene in urine. The use of the holder-vacuum tube device not only saves hands for transfer of the sample to air-tight space, but facilitates sample storage prior to HS-GC analysis.

  11. Data acquisition remote node powered over the communications optical fiber

    International Nuclear Information System (INIS)

    Batista, Antonio J.N.; Sousa, Jorge; Gonçalves, Bruno

    2015-01-01

    Large nuclear fusion reactors, like ITER, will have harsh electromagnetic environments nearby the machine. Foreseeing the necessity for special data acquisition remote nodes, on difficult access locations and as close as possible to the experimental devices, motivated the system design. The architecture is based on the power-over-fiber technology recent advancements and respective implementation aim is to attain a proof of concept for the fusion technology field and others, e.g., high energy physics, industry, etc. The design intends the replacement of traditional copper cables and power supplies, vulnerable to electromagnetic interference, by the communications optical fiber of the data acquisition remote node. Optical fibers provide galvanic isolation, immunity to noisy electromagnetic environments and simultaneously can supply power to the remote node electronics. System architecture uses a laser power converter (array of photovoltaic cells) to convert the laser light, from the optical fiber, into electricity. The generated electrical power is enough for powering the remote node electronics and optoelectronics, such as an ADC, a low power FPGA and an optical transmitter. The laser power converter is also used as the communications receiver and from which the acquisition clock is recovered, providing synchronism between remote data acquisition nodes. Descriptions of the system architecture, tested implementations and future improvements are presented.

  12. Power spectrum analysis for defect screening in integrated circuit devices

    Science.gov (United States)

    Tangyunyong, Paiboon; Cole Jr., Edward I.; Stein, David J.

    2011-12-01

    A device sample is screened for defects using its power spectrum in response to a dynamic stimulus. The device sample receives a time-varying electrical signal. The power spectrum of the device sample is measured at one of the pins of the device sample. A defect in the device sample can be identified based on results of comparing the power spectrum with one or more power spectra of the device that have a known defect status.

  13. Fast control and data acquisition in the neutral beam test facility

    International Nuclear Information System (INIS)

    Luchetta, A.; Manduchi, G.; Taliercio, C.

    2014-01-01

    Highlights: • The paper describes the fast control and data acquisition in the ITER neutral beam test facility. • The usage of real time control in ion beam generation and extraction is proposed. • Real time management of breakdowns is described. • The implementation of event-driven data acquisition is reported. - Abstract: Fast control and data acquisition are required in the ion source test bed of the ITER neutral beam test facility, referred to as SPIDER. Fast control will drive the operation of the power supply systems with particular reference to special asynchronous events, such as the breakdowns. These are short-circuits among grids or between grids and vessel that can occur repeatedly during beam operation. They are normal events and, as such, they will be managed by the fast control system. Cycle time associated to such fast control is down to hundreds of microseconds. Fast data acquisition is required when breakdowns occur. Event-driven data acquisition is triggered in real time by fast control at the occurrence of each breakdown. Pre- and post-event samples are acquired, allowing capturing information on transient phenomena in a whole time-window centered on the event. Sampling rate of event-driven data acquisition is up to 5 MS/s. Fast data acquisition may also be independent of breakdowns as in the case of the cavity ring-down spectroscopy where data chunks are acquired at 100 MS/s in bursts of 1.5 ms every 100 ms and are processed in real time to produce derived measurements. The paper after the description of the SPIDER fast control and data acquisition application will report the system design based on commercially available hardware and the MARTe and MDSplus software frameworks. The results obtained by running a full prototype of the fast control and data acquisition system are also reported and discussed. They demonstrate that all SPIDER fast control and data acquisition requirements can be met in the prototype solution

  14. Fast control and data acquisition in the neutral beam test facility

    Energy Technology Data Exchange (ETDEWEB)

    Luchetta, A., E-mail: adriano.luchetta@igi.cnr.it; Manduchi, G.; Taliercio, C.

    2014-05-15

    Highlights: • The paper describes the fast control and data acquisition in the ITER neutral beam test facility. • The usage of real time control in ion beam generation and extraction is proposed. • Real time management of breakdowns is described. • The implementation of event-driven data acquisition is reported. - Abstract: Fast control and data acquisition are required in the ion source test bed of the ITER neutral beam test facility, referred to as SPIDER. Fast control will drive the operation of the power supply systems with particular reference to special asynchronous events, such as the breakdowns. These are short-circuits among grids or between grids and vessel that can occur repeatedly during beam operation. They are normal events and, as such, they will be managed by the fast control system. Cycle time associated to such fast control is down to hundreds of microseconds. Fast data acquisition is required when breakdowns occur. Event-driven data acquisition is triggered in real time by fast control at the occurrence of each breakdown. Pre- and post-event samples are acquired, allowing capturing information on transient phenomena in a whole time-window centered on the event. Sampling rate of event-driven data acquisition is up to 5 MS/s. Fast data acquisition may also be independent of breakdowns as in the case of the cavity ring-down spectroscopy where data chunks are acquired at 100 MS/s in bursts of 1.5 ms every 100 ms and are processed in real time to produce derived measurements. The paper after the description of the SPIDER fast control and data acquisition application will report the system design based on commercially available hardware and the MARTe and MDSplus software frameworks. The results obtained by running a full prototype of the fast control and data acquisition system are also reported and discussed. They demonstrate that all SPIDER fast control and data acquisition requirements can be met in the prototype solution.

  15. A device for the application of uniaxial strain to single crystal samples for use in synchrotron radiation experiments

    Energy Technology Data Exchange (ETDEWEB)

    Gannon, L. [Clarendon Laboratory, University of Oxford Physics Department, Parks Road, Oxford OX1 3PU (United Kingdom); Diamond Light Source, Harwell Science and Innovation Campus, Didcot OX11 ODE (United Kingdom); Bosak, A. [European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble Cedex (France); Burkovsky, R. G. [European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble Cedex (France); Peter the Great Saint-Petersburg Polytechnic University, 29 Politekhnicheskaya, 195251, St.-Petersburg (Russian Federation); Nisbet, G.; Hoesch, M., E-mail: Moritz.Hoesch@diamond.ac.uk [Diamond Light Source, Harwell Science and Innovation Campus, Didcot OX11 ODE (United Kingdom); Petrović, A. P. [DPMC-MaNEP, Université de Genève, Quai Ernest-Ansermet 24, 1211 Genève 4 (Switzerland)

    2015-10-15

    We present the design, construction, and testing of a straining device compatible with many different synchrotron radiation techniques, in a wide range of experimental environments (including low temperature, high field and ultra-high vacuum). The device has been tested by X-ray diffraction on single crystal samples of quasi-one-dimensional Cs{sub 2}Mo{sub 6}Se{sub 6} and K{sub 2}Mo{sub 6}Se{sub 6}, in which microscopic strains up to a Δc/c = 0.12% ± 0.01% change in the c lattice parameters have been achieved. We have also used the device in an inelastic X-ray scattering experiment, to probe the strain-dependent speed of sound ν along the c axis. A reduction Δν/ν of up to −3.8% was obtained at a strain of Δc/c = 0.25% in K{sub 2}Mo{sub 6}Se{sub 6}.

  16. High performance image acquisition and processing architecture for fast plant system controllers based on FPGA and GPU

    International Nuclear Information System (INIS)

    Nieto, J.; Sanz, D.; Guillén, P.; Esquembri, S.; Arcas, G. de; Ruiz, M.; Vega, J.; Castro, R.

    2016-01-01

    Highlights: • To test an image acquisition and processing system for Camera Link devices based in a FPGA, compliant with ITER fast controllers. • To move data acquired from the set NI1483-NIPXIe7966R directly to a NVIDIA GPU using NVIDIA GPUDirect RDMA technology. • To obtain a methodology to include GPUs processing in ITER Fast Plant Controllers, using EPICS integration through Nominal Device Support (NDS). - Abstract: The two dominant technologies that are being used in real time image processing are Field Programmable Gate Array (FPGA) and Graphical Processor Unit (GPU) due to their algorithm parallelization capabilities. But not much work has been done to standardize how these technologies can be integrated in data acquisition systems, where control and supervisory requirements are in place, such as ITER (International Thermonuclear Experimental Reactor). This work proposes an architecture, and a development methodology, to develop image acquisition and processing systems based on FPGAs and GPUs compliant with ITER fast controller solutions. A use case based on a Camera Link device connected to an FPGA DAQ device (National Instruments FlexRIO technology), and a NVIDIA Tesla GPU series card has been developed and tested. The architecture proposed has been designed to optimize system performance by minimizing data transfer operations and CPU intervention thanks to the use of NVIDIA GPUDirect RDMA and DMA technologies. This allows moving the data directly between the different hardware elements (FPGA DAQ-GPU-CPU) avoiding CPU intervention and therefore the use of intermediate CPU memory buffers. A special effort has been put to provide a development methodology that, maintaining the highest possible abstraction from the low level implementation details, allows obtaining solutions that conform to CODAC Core System standards by providing EPICS and Nominal Device Support.

  17. High performance image acquisition and processing architecture for fast plant system controllers based on FPGA and GPU

    Energy Technology Data Exchange (ETDEWEB)

    Nieto, J., E-mail: jnieto@sec.upm.es [Grupo de Investigación en Instrumentación y Acústica Aplicada, Universidad Politécnica de Madrid, Crta. Valencia Km-7, Madrid 28031 (Spain); Sanz, D.; Guillén, P.; Esquembri, S.; Arcas, G. de; Ruiz, M. [Grupo de Investigación en Instrumentación y Acústica Aplicada, Universidad Politécnica de Madrid, Crta. Valencia Km-7, Madrid 28031 (Spain); Vega, J.; Castro, R. [Asociación EURATOM/CIEMAT para Fusión, Madrid (Spain)

    2016-11-15

    Highlights: • To test an image acquisition and processing system for Camera Link devices based in a FPGA, compliant with ITER fast controllers. • To move data acquired from the set NI1483-NIPXIe7966R directly to a NVIDIA GPU using NVIDIA GPUDirect RDMA technology. • To obtain a methodology to include GPUs processing in ITER Fast Plant Controllers, using EPICS integration through Nominal Device Support (NDS). - Abstract: The two dominant technologies that are being used in real time image processing are Field Programmable Gate Array (FPGA) and Graphical Processor Unit (GPU) due to their algorithm parallelization capabilities. But not much work has been done to standardize how these technologies can be integrated in data acquisition systems, where control and supervisory requirements are in place, such as ITER (International Thermonuclear Experimental Reactor). This work proposes an architecture, and a development methodology, to develop image acquisition and processing systems based on FPGAs and GPUs compliant with ITER fast controller solutions. A use case based on a Camera Link device connected to an FPGA DAQ device (National Instruments FlexRIO technology), and a NVIDIA Tesla GPU series card has been developed and tested. The architecture proposed has been designed to optimize system performance by minimizing data transfer operations and CPU intervention thanks to the use of NVIDIA GPUDirect RDMA and DMA technologies. This allows moving the data directly between the different hardware elements (FPGA DAQ-GPU-CPU) avoiding CPU intervention and therefore the use of intermediate CPU memory buffers. A special effort has been put to provide a development methodology that, maintaining the highest possible abstraction from the low level implementation details, allows obtaining solutions that conform to CODAC Core System standards by providing EPICS and Nominal Device Support.

  18. Smart acquisition EELS

    International Nuclear Information System (INIS)

    Sader, Kasim; Schaffer, Bernhard; Vaughan, Gareth; Brydson, Rik; Brown, Andy; Bleloch, Andrew

    2010-01-01

    We have developed a novel acquisition methodology for the recording of electron energy loss spectra (EELS) using a scanning transmission electron microscope (STEM): 'Smart Acquisition'. Smart Acquisition allows the independent control of probe scanning procedures and the simultaneous acquisition of analytical signals such as EELS. The original motivation for this work arose from the need to control the electron dose experienced by beam-sensitive specimens whilst maintaining a sufficiently high signal-to-noise ratio in the EEL signal for the extraction of useful analytical information (such as energy loss near edge spectral features) from relatively undamaged areas. We have developed a flexible acquisition framework which separates beam position data input, beam positioning, and EELS acquisition. In this paper we demonstrate the effectiveness of this technique on beam-sensitive thin films of amorphous aluminium trifluoride. Smart Acquisition has been used to expose lines to the electron beam, followed by analysis of the structures created by line-integrating EELS acquisitions, and the results are compared to those derived from a standard EELS linescan. High angle annular dark-field images show clear reductions in damage for the Smart Acquisition areas compared to the conventional linescan, and the Smart Acquisition low loss EEL spectra are more representative of the undamaged material than those derived using a conventional linescan. Atomically resolved EELS of all four elements of CaNdTiO show the high resolution capabilities of Smart Acquisition.

  19. Smart acquisition EELS

    Energy Technology Data Exchange (ETDEWEB)

    Sader, Kasim, E-mail: k.sader@leeds.ac.uk [SuperSTEM, J block, Daresbury Laboratory, Warrington, Cheshire, WA4 4AD (United Kingdom); Institute for Materials Research, University of Leeds, LS2 9JT (United Kingdom); Schaffer, Bernhard [SuperSTEM, J block, Daresbury Laboratory, Warrington, Cheshire, WA4 4AD (United Kingdom); Department of Physics and Astronomy, University of Glasgow (United Kingdom); Vaughan, Gareth [Institute for Materials Research, University of Leeds, LS2 9JT (United Kingdom); Brydson, Rik [SuperSTEM, J block, Daresbury Laboratory, Warrington, Cheshire, WA4 4AD (United Kingdom); Institute for Materials Research, University of Leeds, LS2 9JT (United Kingdom); Brown, Andy [Institute for Materials Research, University of Leeds, LS2 9JT (United Kingdom); Bleloch, Andrew [SuperSTEM, J block, Daresbury Laboratory, Warrington, Cheshire, WA4 4AD (United Kingdom); Department of Engineering, University of Liverpool, Liverpool (United Kingdom)

    2010-07-15

    We have developed a novel acquisition methodology for the recording of electron energy loss spectra (EELS) using a scanning transmission electron microscope (STEM): 'Smart Acquisition'. Smart Acquisition allows the independent control of probe scanning procedures and the simultaneous acquisition of analytical signals such as EELS. The original motivation for this work arose from the need to control the electron dose experienced by beam-sensitive specimens whilst maintaining a sufficiently high signal-to-noise ratio in the EEL signal for the extraction of useful analytical information (such as energy loss near edge spectral features) from relatively undamaged areas. We have developed a flexible acquisition framework which separates beam position data input, beam positioning, and EELS acquisition. In this paper we demonstrate the effectiveness of this technique on beam-sensitive thin films of amorphous aluminium trifluoride. Smart Acquisition has been used to expose lines to the electron beam, followed by analysis of the structures created by line-integrating EELS acquisitions, and the results are compared to those derived from a standard EELS linescan. High angle annular dark-field images show clear reductions in damage for the Smart Acquisition areas compared to the conventional linescan, and the Smart Acquisition low loss EEL spectra are more representative of the undamaged material than those derived using a conventional linescan. Atomically resolved EELS of all four elements of CaNdTiO show the high resolution capabilities of Smart Acquisition.

  20. Overview of data acquisition system for SST-1 diagnostics

    International Nuclear Information System (INIS)

    Sharma, Manika; Mansuri, Imran; Raval, Tushar; Sharma, A.L; Pradhan, S.

    2016-01-01

    Highlights: • An account of architecture and data acquisition activities of SST-1 data acquisition system (DAS) for SST-1 diagnostics and subsystems. • PXI based Data acquisition system and CAMAC based Data acquisition system for slow and fast plasma diagnostics. • SST-1 DAS interface and its communication with SST-1 central control system. Integration of SST-1 DAS with timing system. • SST-1 DAS data archival and data analysis. - Abstract: The recent first phase operations of SST-1 in short pulse mode have provided an excellent opportunity for the essential initial tests and benchmark of the SST-1 Data Acquisition System. This paper describes the SST-1 Data Acquisition systems (DAS), which with its heterogeneous composition and distributed architecture, aims to cover a wide range of slow to fast channels interfaced with a large set of diagnostics. The DAS also provides the essential user interface for data acquisition to cater both on and off-line data usage. The central archiving and retrieval service is based on a dual step architecture involving a combination of Network Attached Server (NAS) and a Storage Area Network (SAN). SST-1 Data Acquisition Systems have been reliably operated in the SST-1 experimental campaigns. At present different distributed DAS caters the need of around 130 channels from different SST-1 diagnostics and its subsystems. PXI based DAS and CAMAC based DAS have been chosen to cater the need, with sampling rates varying from 10Ksamples/sec to 1Msamples/sec. For these large sets of channels acquiring from individual diagnostics and subsystems has been a combined setup, subjected to a gradual phase of optimization and tests resulting into a series of improvisations over the recent operations. In order to facilitate a reliable data acquisition, the model further integrates the objects of the systems with the Central Control System of SST-1 using the TCP/IP communication. The associated DAS software essentially addresses the

  1. Overview of data acquisition system for SST-1 diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Manika, E-mail: bithi@ipr.res.in; Mansuri, Imran; Raval, Tushar; Sharma, A.L; Pradhan, S.

    2016-11-15

    Highlights: • An account of architecture and data acquisition activities of SST-1 data acquisition system (DAS) for SST-1 diagnostics and subsystems. • PXI based Data acquisition system and CAMAC based Data acquisition system for slow and fast plasma diagnostics. • SST-1 DAS interface and its communication with SST-1 central control system. Integration of SST-1 DAS with timing system. • SST-1 DAS data archival and data analysis. - Abstract: The recent first phase operations of SST-1 in short pulse mode have provided an excellent opportunity for the essential initial tests and benchmark of the SST-1 Data Acquisition System. This paper describes the SST-1 Data Acquisition systems (DAS), which with its heterogeneous composition and distributed architecture, aims to cover a wide range of slow to fast channels interfaced with a large set of diagnostics. The DAS also provides the essential user interface for data acquisition to cater both on and off-line data usage. The central archiving and retrieval service is based on a dual step architecture involving a combination of Network Attached Server (NAS) and a Storage Area Network (SAN). SST-1 Data Acquisition Systems have been reliably operated in the SST-1 experimental campaigns. At present different distributed DAS caters the need of around 130 channels from different SST-1 diagnostics and its subsystems. PXI based DAS and CAMAC based DAS have been chosen to cater the need, with sampling rates varying from 10Ksamples/sec to 1Msamples/sec. For these large sets of channels acquiring from individual diagnostics and subsystems has been a combined setup, subjected to a gradual phase of optimization and tests resulting into a series of improvisations over the recent operations. In order to facilitate a reliable data acquisition, the model further integrates the objects of the systems with the Central Control System of SST-1 using the TCP/IP communication. The associated DAS software essentially addresses the

  2. The new LLNL AMS sample changer

    International Nuclear Information System (INIS)

    Roberts, M.L.; Norman, P.J.; Garibaldi, J.L.; Hornady, R.S.

    1993-01-01

    The Center for Accelerator Mass Spectrometry at LLNL has installed a new 64 position AMS sample changer on our spectrometer. This new sample changer has the capability of being controlled manually by an operator or automatically by the AMS data acquisition computer. Automatic control of the sample changer by the data acquisition system is a necessary step towards unattended AMS operation in our laboratory. The sample changer uses a fiber optic shaft encoder for rough rotational indexing of the sample wheel and a series of sequenced pneumatic cylinders for final mechanical indexing of the wheel and insertion and retraction of samples. Transit time from sample to sample varies from 4 s to 19 s, depending on distance moved. Final sample location can be set to within 50 microns on the x and y axis and within 100 microns in the z axis. Changing sample wheels on the new sample changer is also easier and faster than was possible on our previous sample changer and does not require the use of any tools

  3. Data Acquisition System Design for Advanced Core-Cooling Mechanism Experiment

    International Nuclear Information System (INIS)

    Zhang, Ziyang; Tian, Fang; Zhang, Tao; Wang, Shen

    2011-01-01

    Data Acquisition System (DAS) design for Advanced Core-Cooling Mechanism Experiment(ACME) is studied in the paper. DAS is an important connection between test facility and result analysis. Firstly, it introduces DAS and its design requirement for ACME. Nearly one thousand data resources need record in ACME. They have different types and acquisition frequencies. In order to record these data, a large scale and high speed layered data acquisition system is developed. Secondly, it discusses the DAS design for ACME, including the analog signal adjusting circuits, clock circuit design, sampling frequencies, data storage and transmission by large database system, anti-interference and etc. Analog signal adjusting circuits are necessary to deal with different kinds of input data to gain standard data resources. Some data change slowly and others change in several seconds according to the test performed on ACME. So it is difficult to use uniform sampling frequencies, and a layered data acquisition system is introduced. A large database is built to store data for ACME test, which keeps data safer and makes subsequent data handling more convenient. A database hot backup is also applied to ensure data safety. The software of DAS is built by Labview, which can provide intuitionist result and friendly interface. Another important function of DAS is the ACME safety protection. Finally, the characteristics and improvement of DAS for ACME is analyzed compared to other test facility. Besides friendly user interface, DAS of ACME can also assure higher data precision and sampling frequency

  4. Comparative study of the characteristics of some suction devices for gas sampling applications; Etude comparative des caracteristiques de quelques dispositifs d'aspiration a l'usage des prelevements de gaz

    Energy Technology Data Exchange (ETDEWEB)

    Donguy, R.; Drouet, J.

    1959-06-15

    Gas sampling (used to determine the characteristics of dusts or aerosols contained in a gas) needs a suction device. In order to select the right device and the right conditions of use, the characteristics and performances of various suction devices (helicoidal and centrifugal aspirators, air pumps, volumetric pumps) have been experimentally measured: flow rate, head loss, sampling volume and duration, aerosol and dust concentration, gas density, nature of the gas, suction circuit configuration, etc.

  5. ORELA data acquisition system hardware. Volume 1: introduction

    International Nuclear Information System (INIS)

    Reynolds, J.W.

    1977-01-01

    The Oak Ridge Electron Linear Accelerator Facility (ORELA) has been specifically designed as a facility for neutron cross-section measurements by the time-of-flight technique. ORELA was designed so that a number of cross-section experiments can be performed simultaneously. This goal of simultaneous operation of several experiments, a maximum of six to date, has been achieved by using the multiple flight paths radiating from the target room, the multiple flight stations on each flight path, the laboratory facilities surrounding the central data area, and a shared data acquisition computer system. The flight stations contain the fast electronics for initial processing of the nuclear detector signals on a time scale of nanoseconds. The laboratories, and in some cases the flight stations, contain the equipment to digitize the nanosecond detector signals on a time scale of a few microseconds. At this point, the data passes into the ORELA Data Acquisition portion of the ORELA Data Handling System. An introduction to the ORELA Data Acquisition System is given, and the component parts of the system are briefly reviewed. Each specifically designed piece of hardware is briefly described with a simplified block diagram. Modifications to standard peripheral devices are reviewed. A list of drawings and programming notes are also included

  6. Catch me if you can: Comparing ballast water sampling skids to traditional net sampling

    Science.gov (United States)

    Bradie, Johanna; Gianoli, Claudio; Linley, Robert Dallas; Schillak, Lothar; Schneider, Gerd; Stehouwer, Peter; Bailey, Sarah

    2018-03-01

    With the recent ratification of the International Convention for the Control and Management of Ships' Ballast Water and Sediments, 2004, it will soon be necessary to assess ships for compliance with ballast water discharge standards. Sampling skids that allow the efficient collection of ballast water samples in a compact space have been developed for this purpose. We ran 22 trials on board the RV Meteor from June 4-15, 2015 to evaluate the performance of three ballast water sampling devices (traditional plankton net, Triton sampling skid, SGS sampling skid) for three organism size classes: ≥ 50 μm, ≥ 10 μm to Natural sea water was run through the ballast water system and untreated samples were collected using paired sampling devices. Collected samples were analyzed in parallel by multiple analysts using several different analytic methods to quantify organism concentrations. To determine whether there were differences in the number of viable organisms collected across sampling devices, results were standardized and statistically treated to filter out other sources of variability, resulting in an outcome variable representing the mean difference in measurements that can be attributed to sampling devices. These results were tested for significance using pairwise Tukey contrasts. Differences in organism concentrations were found in 50% of comparisons between sampling skids and the plankton net for ≥ 50 μm, and ≥ 10 μm to < 50 μm size classes, with net samples containing either higher or lower densities. There were no differences for < 10 μm organisms. Future work will be required to explicitly examine the potential effects of flow velocity, sampling duration, sampled volume, and organism concentrations on sampling device performance.

  7. Full information acquisition in scanning probe microscopy and spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Jesse, Stephen; Belianinov, Alex; Kalinin, Sergei V.; Somnath, Suhas

    2017-04-04

    Apparatus and methods are described for scanning probe microscopy and spectroscopy based on acquisition of full probe response. The full probe response contains valuable information about the probe-sample interaction that is lost in traditional scanning probe microscopy and spectroscopy methods. The full probe response is analyzed post data acquisition using fast Fourier transform and adaptive filtering, as well as multivariate analysis. The full response data is further compressed to retain only statistically significant components before being permanently stored.

  8. 21 CFR 868.1100 - Arterial blood sampling kit.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arterial blood sampling kit. 868.1100 Section 868...

  9. Post-Acquisition IT Integration

    DEFF Research Database (Denmark)

    Henningsson, Stefan; Yetton, Philip

    2013-01-01

    The extant research on post-acquisition IT integration analyzes how acquirers realize IT-based value in individual acquisitions. However, serial acquirers make 60% of acquisitions. These acquisitions are not isolated events, but are components in growth-by-acquisition programs. To explain how...... serial acquirers realize IT-based value, we develop three propositions on the sequential effects on post-acquisition IT integration in acquisition programs. Their combined explanation is that serial acquirers must have a growth-by-acquisition strategy that includes the capability to improve...... IT integration capabilities, to sustain high alignment across acquisitions and to maintain a scalable IT infrastructure with a flat or decreasing cost structure. We begin the process of validating the three propositions by investigating a longitudinal case study of a growth-by-acquisition program....

  10. New methodology of designing inexpensive hybrid control-acquisition systems for mechatronic constructions.

    Science.gov (United States)

    Augustyn, Jacek

    2013-12-13

    This article presents a new methodology for designing a hybrid control and acquisition system consisting of a 32-bit SoC microsystem connected via a direct Universal Serial Bus (USB) with a standard commercial off-the-shelf (COTS) component running the Android operating system. It is proposed to utilize it avoiding the use of an additional converter. An Android-based component was chosen to explore the potential for a mobile, compact and energy efficient solution with easy to build user interfaces and easy wireless integration with other computer systems. This paper presents results of practical implementation and analysis of experimental real-time performance. It covers closed control loop time between the sensor/actuator module and the Android operating system as well as the real-time sensor data stream within such a system. Some optimisations are proposed and their influence on real-time performance was investigated. The proposed methodology is intended for acquisition and control of mechatronic systems, especially mobile robots. It can be used in a wide range of control applications as well as embedded acquisition-recording devices, including energy quality measurements, smart-grids and medicine. It is demonstrated that the proposed methodology can be employed without developing specific device drivers. The latency achieved was less than 0.5 ms and the sensor data stream throughput was on the order of 750 KB/s (compared to 3 ms latency and 300 KB/s in traditional solutions).

  11. Enabling optical metrology on small 5×5μm2 in-cell targets to support flexible sampling and higher order overlay and CD control for advanced logic devices nodes

    Science.gov (United States)

    Salerno, Antonio; de la Fuente, Isabel; Hsu, Zack; Tai, Alan; Chang, Hammer; McNamara, Elliott; Cramer, Hugo; Li, Daoping

    2018-03-01

    In next generation Logic devices, overlay control requirements shrink to sub 2.5nm level on-product overlay. Historically on-product overlay has been defined by the overlay capability of after-develop in-scribe targets. However, due to design and dimension, the after development metrology targets are not completely representative for the final overlay of the device. In addition, they are confined to the scribe-lane area, which limits the sampling possibilities. To address these two issues, metrology on structures matching the device structure and which can be sampled with high density across the device is required. Conventional after-etch CDSEM techniques on logic devices present difficulties in discerning the layers of interest, potential destructive charging effects and finally, they are limited by the long measurement times[1] [2] [3] . All together, limit the sampling densities and making CDSEM less attractive for control applications. Optical metrology can overcome most of these limitations. Such measurement, however, does require repetitive structures. This requirement is not fulfilled by logic devices, as the features vary in pitch and CD over the exposure field. The solution is to use small targets, with a maximum pad size of 5x5um2 , which can easily be placed in the logic cell area. These targets share the process and architecture of the device features of interest, but with a modified design that replicates as close as possible the device layout, allowing for in-device metrology for both CD and Overlay. This solution enables measuring closer to the actual product feature location and, not being limited to scribe-lanes, it opens the possibility of higher-density sampling schemes across the field. In summary, these targets become the facilitator of in-device metrology (IDM), that is, enabling the measurements both in-device Overlay and the CD parameters of interest and can deliver accurate, high-throughput, dense and after-etch measurements for Logic

  12. Smart Device for the Determination of Heart Rate Variability in Real Time

    Directory of Open Access Journals (Sweden)

    David Naranjo-Hernández

    2017-01-01

    Full Text Available This work presents a first approach to the design, development, and implementation of a smart device for the real-time measurement and detection of alterations in heart rate variability (HRV. The smart device follows a modular design scheme, which consists of an electrocardiogram (ECG signal acquisition module, a processing module and a wireless communications module. From five-minute ECG signals, the processing module algorithms perform a spectral estimation of the HRV. The experimental results demonstrate the viability of the smart device and the proposed processing algorithms.

  13. The BaBar Data Acquisition System

    CERN Document Server

    Scott, I; Grosso, P; Huffer, M E; O'Grady, C; Russell, J J

    1999-01-01

    The BaBar experiment at the Stanford Linear Accelerator Center is designed to perform a search for CP violation by ana-lyzing the decays of a very large sample of B and B(Bar) mesons produced at the high luminosity PEP-II accelerator. The data acquisition system must cope with a sustained high event rate, while supporting real time feature extraction and data compression with minimal dead time. The BaBar data acquisition system is based around a common VME interface to the electronics read-out of the separate detec-tor subsystems. Data from the front end electronics is read into commercial VME processors via a custom "Personality Card" and PCI interface. The commercial CPUs run the Tornado operating system to provide a platform for detector subsystem code to perform the necessary data processing. The data is read out via a non-blocking network switch to a farm of commercial UNIX processors. The current implementation of the BaBar data acquisition sys-tem has been shown to sustain a Level 1 trigger rate of 1.3...

  14. Wideband 4-diode sampling circuit

    Science.gov (United States)

    Wojtulewicz, Andrzej; Radtke, Maciej

    2016-09-01

    The objective of this work was to develop a wide-band sampling circuit. The device should have the ability to collect samples of a very fast signal applied to its input, strengthen it and prepare for further processing. The study emphasizes the method of sampling pulse shaping. The use of ultrafast pulse generator allows sampling signals with a wide frequency spectrum, reaching several gigahertzes. The device uses a pulse transformer to prepare symmetrical pulses. Their final shape is formed with the help of the step recovery diode, two coplanar strips and Schottky diode. Made device can be used in the sampling oscilloscope, as well as other measurement system.

  15. Data processing device

    International Nuclear Information System (INIS)

    Kita, Yoshio.

    1994-01-01

    A data processing device for use in a thermonuclear testing device comprises a frequency component judging section for analog signals, a sample time selection section based on the result of the judgement, a storing memory section for selecting digital data memorized in the sampling time. Namely, the frequency components of the analog signals are detected by the frequency component judging section, and one of a plurality of previously set sampling times is selected by the sampling time selection section based on the result of the judgement of the frequency component judging section. Then, digital data obtained by A/D conversion are read and preliminarily memorized in the storing memory section. Subsequently, the digital data memorized in the sampling time selected by the sampling time selection section are selected and transmitted to a superior computer. The amount of data to be memorized can greatly reduced, to reduce the cost. (N.H.)

  16. The use of gamma ray computed tomography to investigate soil compaction due to core sampling devices

    International Nuclear Information System (INIS)

    Pires, Luiz F.; Arthur, Robson C.J.; Correchel, Vladia; Bacchi, Osny O.S.; Reichardt, Klaus; Brasil, Rene P. Camponez do

    2004-01-01

    Compaction processes can influence soil physical properties such as soil density, porosity, pore size distribution, and processes like soil water and nutrient movements, root system distribution, and others. Soil porosity modification has important consequences like alterations in results of soil water retention curves. These alterations may cause differences in soil water storage calculations and matrix potential values, which are utilized in irrigation management systems. Because of this, soil-sampling techniques should avoid alterations of sample structure. In this work soil sample compaction caused by core sampling devices was investigated using the gamma ray computed tomography technique. A first generation tomograph with fixed source-detector arrangement and translation/rotational movements of the sample was utilized to obtain the images. The radioactive source is 241 Am, with an activity of 3.7 GBq, and the detector consists of a 3 in. x 3 in. NaI(Tl) scintillation crystal coupled to a photomultiplier tube. Soil samples were taken from an experimental field utilizing cylinders 4.0 cm high and 2.6 cm in diameter. Based on image analyses it was possible to detect compacted regions in all samples next to the cylinder wall due to the sampling system. Tomographic unit profiles of the sample permitted to identify higher values of soil density for deeper regions of the sample, and it was possible to determine the average densities and thickness of these layers. Tomographic analyses showed to be a very useful tool for soil compaction characterization and presented many advantages in relation to traditional methods. (author)

  17. Laser speckle decorrelation for fingerprint acquisition

    International Nuclear Information System (INIS)

    Schirripa Spagnolo, Giuseppe; Cozzella, Lorenzo

    2012-01-01

    Biometry is gaining popularity as a physical security approach in situations where a high level of security is necessary. Currently, biometric solutions are embedded in a very large and heterogeneous group of applications. One of the most sensible is for airport security access to boarding gates. More airports are introducing biometric solutions based on face, fingerprint or iris recognition for passenger identification. In particular, fingerprints are the most widely used biometric, and they are mandatorily included in electronic identification documents. One important issue, which is difficult to address in traditional fingerprint acquisition systems, is preventing contact between subsequent users; sebum, which can be a potential vector for contagious diseases. Currently, non-contact devices are used to overcome this problem. In this paper, a new contact device based on laser speckle decorrelation is presented. Our system has the advantage of being compact and low-cost compared with an actual contactless system, allowing enhancement of the sebum pattern imaging contrast in a simple and low-cost way. Furthermore, it avoids the spreading of contagious diseases. (paper)

  18. Automatic data acquisition system of environmental radiation monitor with a personal computer

    International Nuclear Information System (INIS)

    Ohkubo, Tohru; Nakamura, Takashi.

    1984-05-01

    The automatic data acquisition system of environmental radiation monitor was developed in a low price by using a PET personal computer. The count pulses from eight monitors settled at four site boundaries were transmitted to a radiation control room by a signal transmission device and analyzed by the computer via 12 channel scaler and PET-CAMAC Interface for graphic display and printing. (author)

  19. Behavioral responses of three lemur species to different food enrichment devices.

    Science.gov (United States)

    Shapiro, Morgan E; Shapiro, Hannah G; Ehmke, Erin E

    2018-05-01

    Environmental enrichment is a tool used to promote the welfare and well-being of captive animals by encouraging the display of species-specific behaviors and reducing the stress or boredom induced by captive environments. Lemurs are highly endangered, yet few studies have analyzed the behavioral impacts of enrichment on captive populations. We studied the impacts of two novel enrichment devices on three lemur species (ring-tailed lemurs [Lemur catta], red-ruffed lemurs [Varecia rubra], and Coquerel's sifaka [Propithecus coquereli]) to determine both the overall and species-specific impacts of enrichment on lemur behavior. We recorded lemur behavior using the continuous sampling method to obtain behavior duration and analyzed our results using ANOVA Repeated Measures. Results showed enrichment effectiveness differed for each species and that different enrichment devices had varying impacts on lemur behavior across all species. We attributed the differences in species-specific responses to the unique locomotor patterns and methods of diet acquisition of each species, and the variances in behavioral responses across all species to the characteristics of each device. Our study highlights the importance of species-specific enrichment and encourages further research in this field in order to maximize the positive effects of enrichment, which in turn has the potential to affect the overall well-being of captive populations. © 2018 Wiley Periodicals, Inc.

  20. The generic methodology for verification and validation applied to medium range anti-tank simulation training devices

    NARCIS (Netherlands)

    Voogd, J.M.; Roza, M.

    2015-01-01

    The Dutch Ministry of Defense (NL-MoD) has recently acquired an update of its medium range anti tank (MRAT) missile system, called the GILL. The update to the SPIKE Long Range (LR) weapon system is accompanied with the acquisition of new simulation training devices (STDs). These devices are bought

  1. A feasibility study of a PET/MRI insert detector using strip-line and waveform sampling data acquisition.

    Science.gov (United States)

    Kim, H; Chen, C-T; Eclov, N; Ronzhin, A; Murat, P; Ramberg, E; Los, S; Wyrwicz, Alice M; Li, Limin; Kao, C-M

    2015-06-01

    We are developing a time-of-flight Positron Emission Tomography (PET) detector by using silicon photo-multipliers (SiPM) on a strip-line and high speed waveform sampling data acquisition. In this design, multiple SiPMs are connected on a single strip-line and signal waveforms on the strip-line are sampled at two ends of the strip to reduce readout channels while fully exploiting the fast time response of SiPMs. In addition to the deposited energy and time information, the position of the hit SiPM along the strip-line is determined by the arrival time difference of the waveform. Due to the insensitivity of the SiPMs to magnetic fields and the compact front-end electronics, the detector approach is highly attractive for developing a PET insert system for a magnetic resonance imaging (MRI) scanner to provide simultaneous PET/MR imaging. To investigate the feasibility, experimental tests using prototype detector modules have been conducted inside a 9.4 Tesla small animal MRI scanner (Bruker BioSpec 94/30 imaging spectrometer). On the prototype strip-line board, 16 SiPMs (5.2 mm pitch) are installed on two strip-lines and coupled to 2 × 8 LYSO scintillators (5.0 × 5.0 × 10.0 mm 3 with 5.2 mm pitch). The outputs of the strip-line boards are connected to a Domino-Ring-Sampler (DRS4) evaluation board for waveform sampling. Preliminary experimental results show that the effect of interference on the MRI image due to the PET detector is negligible and that PET detector performance is comparable with the results measured outside the MRI scanner.

  2. New System For Tokamak T-10 Experimental Data Acquisition, Data Handling And Remote Access

    International Nuclear Information System (INIS)

    Sokolov, M. M.; Igonkina, G. B.; Koutcherenko, I. Yu.; Nurov, D. N.

    2008-01-01

    For carrying out the experiments on nuclear fusion devices in the Institute of Nuclear Fusion, Moscow, a system for experimental data acquisition, data handling and remote access (further 'DAS-T10') was developed and has been used in the Institute since the year 2000. The DAS-T10 maintains the whole cycle of experimental data handling: from configuration of data measuring equipment and acquisition of raw data from the fusion device (the Device), to presentation of math-processed data and support of the experiment data archive. The DAS-T10 provides facilities for the researchers to access the data both at early stages of an experiment and well afterwards, locally from within the experiment network and remotely over the Internet.The DAS-T10 is undergoing a modernization since the year 2007. The new version of the DAS-T10 will accommodate to modern data measuring equipment and will implement improved architectural solutions. The innovations will allow the DAS-T10 to produce and handle larger amounts of experimental data, thus providing the opportunities to intensify and extend the fusion researches. The new features of the DAS-T10 along with the existing design principles are reviewed in this paper

  3. Acquisition System Verification for Energy Efficiency Analysis of Building Materials

    Directory of Open Access Journals (Sweden)

    Natalia Cid

    2017-08-01

    Full Text Available Climate change and fossil fuel depletion foster interest in improving energy efficiency in buildings. There are different methods to achieve improved efficiency; one of them is the use of additives, such as phase change materials (PCMs. To prove this method’s effectiveness, a building’s behaviour should be monitored and analysed. This paper describes an acquisition system developed for monitoring buildings based on Supervisory Control and Data Acquisition (SCADA and with a 1-wire bus network as the communication system. The system is empirically tested to prove that it works properly. With this purpose, two experimental cubicles are made of self-compacting concrete panels, one of which has a PCM as an additive to improve its energy storage properties. Both cubicles have the same dimensions and orientation, and they are separated by six feet to avoid shadows. The behaviour of the PCM was observed with the acquisition system, achieving results that illustrate the differences between the cubicles directly related to the PCM’s characteristics. Data collection devices included in the system were temperature sensors, some of which were embedded in the walls, as well as humidity sensors, heat flux density sensors, a weather station and energy counters. The analysis of the results shows agreement with previous studies of PCM addition; therefore, the acquisition system is suitable for this application.

  4. 48 CFR 252.239-7016 - Telecommunications security equipment, devices, techniques, and services.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Telecommunications... SOLICITATION PROVISIONS AND CONTRACT CLAUSES Text of Provisions And Clauses 252.239-7016 Telecommunications... clause: Telecommunications Security Equipment, Devices, Techniques, and Services (DEC 1991) (a...

  5. Study of measurement of the alcohol biomarker phosphatidylethanol (PEth) in dried blood spot (DBS) samples and application of a volumetric DBS device.

    Science.gov (United States)

    Beck, Olof; Kenan Modén, Naama; Seferaj, Sabina; Lenk, Gabriel; Helander, Anders

    2018-04-01

    Phosphatidylethanol (PEth) is a group of phospholipids formed in cell membranes following alcohol consumption. PEth measurement in whole blood samples is established as a specific alcohol biomarker with clinical and medico-legal applications. This study further evaluated the usefulness of dried blood spot (DBS) samples collected on filter paper for PEth measurement. Specimens used were surplus volumes of venous whole blood sent for routine LC-MS/MS quantification of PEth 16:0/18:1, the major PEth homolog. DBS samples were prepared by pipetting blood on Whatman 903 Protein Saver Cards and onto a volumetric DBS device (Capitainer). The imprecision (CV) of the DBS sample amount based on area and weight measurements of spot punches were 23-28%. Investigation of the relationship between blood hematocrit and PEth concentration yielded a linear, positive correlation, and at around 1.0-1.5μmol/L PEth 16:0/18:1, the PEth concentration increased by ~0.1μmol/L for every 5% increase in hematocrit. There was a close agreement between the PEth concentrations obtained with whole blood samples and the corresponding results using Whatman 903 (PEth DBS =1.026 PEth WB +0.013) and volumetric device (PEth DBS =1.045 PEth WB +0.016) DBS samples. The CV of PEth quantification in DBS samples at concentrations≥0.05μmol/L were ≤15%. The present results further confirmed the usefulness of DBS samples for PEth measurement. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. FireSignal - Data Acquisition and Control System Software

    International Nuclear Information System (INIS)

    Neto, A.; Fernandes, H.; Duarte, A.; Carvalho, B.; Sousa, J.; Valcarcel, D.; Varandas, C.; Hron, M.

    2006-01-01

    Control of fusion devices requires good, non-ambiguous, easy to use user-interfaces to configure hardware devices. To solve this problem a highly generic system for data control and acquisition has been developed. Among the main features it allows remote hardware configuration, shot launching, data sharing between connected users and experiment monitoring. The system is fully distributed: the hardware driver nodes, clients and server are completely independent from each other and might be running in different operating systems and programmed in different languages. All the communication is provided through the Common Object Request Broker Architecture (CORBA) protocol. FireSignal was designed from the beginning to be as independent as possible from any kind of constraints as it's a plugin based system. Database, data viewers and the security system are some examples of what can easily be changed and adapted to the target machine's needs. All hardware is described in eXtendend Markup Language (XML) and from this information the FireSignal client application can build automatically Graphical User Interfaces (GUI) and validate the user's parameter configuration. Any type of hardware can be integrated in the system as long as it is described in XML and the respective driver is developed. Any modern programming language can be used to develop these drivers, and currently we use Python and Java generic drivers. All data storage and indexing is time stamped event-based s. Nodes are responsible for tagging the acquired samples with the absolute time stamps and to react to machine events. FireSignal is currently being used to control the ISTTOK/PT and CASTOR/CZ tokamaks. (author)

  7. Mergers and Acquisitions

    OpenAIRE

    Frasch, Manfred; Leptin, Maria

    2000-01-01

    Mergers and acquisitions (M&As) are booming a strategy of choice for organizations attempting to maintain a competitive advantage. Previous research on mergers and acquisitions declares that acquirers do not normally benefit from acquisitions. Targets, on the other hand, have a tendency of gaining positive returns in the few days surrounding merger announcements due to several characteristic on the acquisitions deal. The announcement period wealth effect on acquiring firms, however, is as cle...

  8. Programmable automatic alpha--beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.

    1978-01-01

    A programmable automatic alpha-beta air sample counter was developed for routine sample counting by operational health physics personnel. The system is composed of an automatic sample changer utilizing a large silicon diode detector, an electronic counting system with energy analysis capability, an automatic data acquisition controller, an interface module, and a teletypewriter with paper tape punch and paper tape reader. The system is operated through the teletypewriter keyboard and the paper tape reader, which are used to instruct the automatic data acquisition controller. Paper tape programs are provided for background counting, Chi 2 test, and sample counting. Output data are printed by the teletypewriter on standard continuous roll or multifold paper. Data are automatically corrected for background and counter efficiency

  9. Magnetic sensor device

    NARCIS (Netherlands)

    2009-01-01

    The present invention provides a sensor device and a method for detg. the presence and/or amt. of target moieties in a sample fluid, the target moieties being labeled with magnetic or magnetizable objects. The sensor device comprises a magnetic field generating means adapted for applying a retention

  10. On the choice of structures of equipment for preliminary data processing for a data acquisition subsystem of the automation control system for controlling technological parameters of tokamak devices

    International Nuclear Information System (INIS)

    Bondarenko, I.M.; Gerasimov, V.P.; Mozin, I.V.; Repin, S.S.; Skosarev, V.A.

    1982-01-01

    The necessity is substantiated to use a complex approach to constructing measuring channels of data acquisition subsystems in automation control systems for controlling technological processes in tokamak thermonuclear installations including preliminary data processing equipment, incorporated devices and measuring converters, which enables to minimize the whole bulk of equipment units, while attaining the best metrological features of the channels. Some examples are given designing measuring channels for different kind of signals. Special attention is paid to the choice of structures of measuring channels for signals from sensors under high voltage isolated from the ground potential. It is found reasonable to use analog-time data conversion and optoelectronic isolating elements from the viewpoint of simplicity of apparatus, good manufacturing technology and adjusting measuring channels elements

  11. Determining the sample size required to establish whether a medical device is non-inferior to an external benchmark.

    Science.gov (United States)

    Sayers, Adrian; Crowther, Michael J; Judge, Andrew; Whitehouse, Michael R; Blom, Ashley W

    2017-08-28

    The use of benchmarks to assess the performance of implants such as those used in arthroplasty surgery is a widespread practice. It provides surgeons, patients and regulatory authorities with the reassurance that implants used are safe and effective. However, it is not currently clear how or how many implants should be statistically compared with a benchmark to assess whether or not that implant is superior, equivalent, non-inferior or inferior to the performance benchmark of interest.We aim to describe the methods and sample size required to conduct a one-sample non-inferiority study of a medical device for the purposes of benchmarking. Simulation study. Simulation study of a national register of medical devices. We simulated data, with and without a non-informative competing risk, to represent an arthroplasty population and describe three methods of analysis (z-test, 1-Kaplan-Meier and competing risks) commonly used in surgical research. We evaluate the performance of each method using power, bias, root-mean-square error, coverage and CI width. 1-Kaplan-Meier provides an unbiased estimate of implant net failure, which can be used to assess if a surgical device is non-inferior to an external benchmark. Small non-inferiority margins require significantly more individuals to be at risk compared with current benchmarking standards. A non-inferiority testing paradigm provides a useful framework for determining if an implant meets the required performance defined by an external benchmark. Current contemporary benchmarking standards have limited power to detect non-inferiority, and substantially larger samples sizes, in excess of 3200 procedures, are required to achieve a power greater than 60%. It is clear when benchmarking implant performance, net failure estimated using 1-KM is preferential to crude failure estimated by competing risk models. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No

  12. Exploring the use of mobile technologies for the acquisition of clinical skills.

    Science.gov (United States)

    Clay, Collette A

    2011-08-01

    Mobile learning has the potential to supplement information communication technology (ICT), online learning and the traditional teaching and learning methods to educate practitioners in the clinical practice area. Following the development of several Post Graduate modules of learning for the theory and clinical skills required to undertake the Newborn Infant Physical Examination (NIPE), a small research study was undertaken to combine mobile learning and NIPE. The research study explored the hypothesis that mobile devices could be used in pedagogically effective ways to support and enhance the learning and acquisition of clinical skills in the clinical arena. Participants in the study each received a handheld mobile device (iPod) that had been loaded with several Reusable Learning Objects (RLO) outlining each aspect of the physical examination to be performed. At the end of the module (12 weeks in duration), each participant completed an evaluation questionnaire. Participants confirmed that mobile learning afforded flexibility in time and place of learning and captured their interest in the learning material. This study reports that the use of mobile technology for skill acquisition is creative and innovative, placing learning firmly in the hands of the learner. Copyright © 2010 Elsevier Ltd. All rights reserved.

  13. The collection and analysis of transient test data using the mobile instrumentation data acquisition system (MIDAS)

    International Nuclear Information System (INIS)

    Uncapher, W.L.; Arviso, M.

    1995-01-01

    Packages designed to transport radioactive materials are required to survive exposure to environments defined in Code of Federal Regulations. Cask designers can investigate package designs through structural and thermal testing of full-scale packages, components, or representative models. The acquisition of reliable response data from instrumentation measurement devices is an essential part of this testing activity. Sandia National Laboratories, under the sponsorship of the US Department of Energy (DOE), has developed the Mobile Instrumentation Data Acquisition System (MIDAS) dedicated to the collection and processing of structural and thermal data from regulatory tests

  14. CAMAC based Test Signal Generator using Re-configurable device

    International Nuclear Information System (INIS)

    Sharma, Atish; Raval, Tushar; Srivastava, Amit K; Reddy, D Chenna

    2010-01-01

    There are many different types of signal generators, with different purposes and applications (and at varying levels of expense). In general, no device is suitable for all possible applications. Hence the selection of signal generator is as per requirements. For SST-1 Data Acquisition System requirements, we have developed a CAMAC based Test Signal Generator module using Re-configurable device (CPLD). This module is based on CAMAC interface but can be used for testing both CAMAC and PXI Data Acquisition Systems in SST-1 tokamak. It can also be used for other similar applications. Unlike traditional signal generators, which are embedded hardware, it is a flexible hardware unit, programmable through Graphical User Interface (GUI) developed in LabVIEW application development tool. The main aim of this work is to develop a signal generator for testing our data acquisition interface for a large number of channels simultaneously. The module front panel has various connectors like LEMO and D type connectors for signal interface. The module can be operated either in continuous signal generation mode or in triggered mode depending upon application. This can be done either by front panel switch or through CAMAC software commands (for remote operation). Similarly module reset and trigger generation operation can be performed either through front panel push button switch or through software CAMAC commands. The module has the facility to accept external TTL level trigger and clock through LEMO connectors. The module can also generate trigger and the clock signal, which can be delivered to other devices through LEMO connectors. The module generates two types of signals: Analog and digital (TTL level). The analog output (single channel) is generated from Digital to Analog Converter through CPLD for various types of waveforms like Sine, Square, Triangular and other wave shape that can vary in amplitude as well as in frequency. The module is quite useful to test up to 32 channels

  15. Pipe closing device

    International Nuclear Information System (INIS)

    Klahn, F.C.; Nolan, J.H.; Wills, C.

    1979-01-01

    The closing device closes the upper end of a support tube for monitoring samples. It meshes with the upper connecting piece of the monitorung sample capsule, and loads the capsule within the bore of the support tube, so that it is fixed but can be released. The closing device consists of an interlocking component with a chamber and several ratchets which hang down. The interlocking component surrounds the actuating component for positioning the ratchets. The interlocking and actuating components are movable axially relative to each other. (DG) [de

  16. Automatic Control and Data Acquisition System for Combustion Laboratory Applications.

    Science.gov (United States)

    1982-10-01

    O VPI Access~.ion FCr- 1473 2 UNCLASSIFIED Approved for public release; distribution unlimited JAutomatic Control and Data Acquisition System for...unit. The CPU/ROK board includes a 16 bit microprocessor chip which decodes and executes all in- structions, and controls all data transfers. The 12K...in the limited memory space of 32K of the HP-85 33 ACQDTA’ 1) Controls DevicesCRAIN ,2) Acquires Photodiods Output$ 3) Stores Data o Disc 1

  17. DATA ACQUISITION FOR SNS BEAM LOSS MONITOR SYSTEM

    International Nuclear Information System (INIS)

    YENG, Y.; GASSNER, D.; HOFF, L.; WITKOVER, R.

    2003-01-01

    The Spallation Neutron Source (SNS) beam loss monitor system uses VME based electronics to measure the radiation produced by lost beam. Beam loss signals from cylindrical argon-filled ion chambers and neutron detectors will be conditioned in analog front-end (AFE) circuitry. These signals will be digitized and further processed in a dedicated VME crate. Fast beam inhibit and low-level, long-term loss warnings will be generated to provide machine protection. The fast loss data will have a bandwidth of 35kHz. While the low level, long-term loss data will have much higher sensitivity. This is further complicated by the 3 decade range of intensity as the Ring accumulates beam. Therefore a bandwidth of 100kHz and dynamic range larger than 21 bits data acquisition system will be required for this purpose. Based on the evaluation of several commercial ADC modules in preliminary design phase, a 24 bits Sigma-Delta data acquisition VME bus card was chosen as the SNS BLM digitizer. An associated vxworks driver and EPICS device support module also have been developed at BNL. Simulating test results showed this system is fully qualified for both fast loss and low-level, long-term loss application. The first prototype including data acquisition hardware setup and EPICS software (running database and OPI clients) will be used in SNS Drift Tube Linac (DTL) system commissioning

  18. MATLAB Simulation of RFID Communication Protocol for Sensor Data Acquisition

    Directory of Open Access Journals (Sweden)

    Soumen GHOSH

    2015-05-01

    Full Text Available Data acquisition processes the sampling and conditioning the signals that measure real world physical conditions such as temperature, pressure, flow etc. and convert the signal into in appropriate format for displaying and transmission to remote end. Now a days RFID i.e. Radio Frequency Identification plays a vital role in Data acquisition system. The present article proposes a smart DAS scheme containing RFID reader and Active tag. The data acquisition system is interfaced with tag through I2C bus. The reader communicates with tag following RFID communication protocol requesting to send the logged data which are refreshed and stored into tag memory periodically. The communication is simulated using MATLAB software successfully.

  19. Structure and data presentation in the data acquisition system for the SFINKS device

    International Nuclear Information System (INIS)

    Kul'man, N.Yu.

    1988-01-01

    The aim of the paper is to create a convenient system to describe the data structure coming from the data acquisition electronics. A language to describe the data structure to accordance with the setup detectors which allows one to make changes in the processing system with the changes of the setup configuration has been proposed. The inner presentation is realized in the form of trees in the ZBOOK system, widely used in high energy physics. Events are treated according to the description and are in the ZBOOK banks. The data are written on the tape in the computer-independent EP-format

  20. ORELA data acquisition system hardware. Vol 4. ORELA device controllers (Q-5098)

    International Nuclear Information System (INIS)

    Reynolds, J.W.; Wintenberg, R.E.

    1977-01-01

    A report is given describing the programming, word formats, control signals, voltage levels, connector layouts, ground isolation, and a theory of operation with a simplified logic diagram for the Oak Ridge Electron Linear Accelerator (ORELA) Device Controllers. The ORELA Isolated Pulse Generators are also described

  1. Infrared thermal annealing device

    International Nuclear Information System (INIS)

    Gladys, M.J.; Clarke, I.; O'Connor, D.J.

    2003-01-01

    A device for annealing samples within an ultrahigh vacuum (UHV) scanning tunneling microscopy system was designed, constructed, and tested. The device is based on illuminating the sample with infrared radiation from outside the UHV chamber with a tungsten projector bulb. The apparatus uses an elliptical mirror to focus the beam through a sapphire viewport for low absorption. Experiments were conducted on clean Pd(100) and annealing temperatures in excess of 1000 K were easily reached

  2. Development of a data acquisition system using a RISC/UNIXTM workstation

    International Nuclear Information System (INIS)

    Takeuchi, Y.; Tanimori, T.; Yasu, Y.

    1993-01-01

    We have developed a compact data acquisition system on RISC/UNIX workstations. A SUN TM SPARCstation TM IPC was used, in which an extension bus 'SBus TM ' was linked to a VMEbus. The transfer rate achieved was better than 7 Mbyte/s between the VMEbus and the SUN. A device driver for CAMAC was developed in order to realize an interruptive feature in UNIX. In addition, list processing has been incorporated in order to keep the high priority of the data handling process in UNIX. The successful developments of both device driver and list processing have made it possible to realize the good real-time feature on the RISC/UNIX system. Based on this architecture, a portable and versatile data taking system has been developed, which consists of a graphical user interface, I/O handler, user analysis process, process manager and a CAMAC device driver. (orig.)

  3. Sieve-based device for MALDI sample preparation. III. Its power for quantitative measurements.

    Science.gov (United States)

    Molin, Laura; Cristoni, Simone; Seraglia, Roberta; Traldi, Pietro

    2011-02-01

    The solid sample inhomogeneity is a weak point of traditional MALDI deposition techniques that reflects negatively on quantitative analysis. The recently developed sieve-based device (SBD) sample deposition method, based on the electrospraying of matrix/analyte solutions through a grounded sieve, allows the homogeneous deposition of microcrystals with dimensions smaller than that of the laser spot. In each microcrystal the matrix/analyte molar ratio can be considered constant. Then, by irradiating different portions of the microcrystal distribution an identical response is obtained. This result suggests the employment of SBD in the development of quantitative procedures. For this aim, mixtures of different proteins of known molarity were analyzed, showing a good relationship between molarity and intensity ratios. This behaviour was also observed in the case of proteins with quite different ionic yields. The power of the developed method for quantitative evaluation was also tested by the measurement of the abundance of IGPP[Oxi]GPP[Oxi]GLMGPP (m/z 1219) present in the collagen-α-5(IV) chain precursor, differently expressed in urines from healthy subjects and diabetic-nephropathic patients, confirming its overexpression in the presence of nephropathy. The data obtained indicate that SBD is a particularly effective method for quantitative analysis also in biological fluids of interest. Copyright © 2011 John Wiley & Sons, Ltd.

  4. Are Portable Stereophotogrammetric Devices Reliable in Facial Imaging? A Validation Study of VECTRA H1 Device.

    Science.gov (United States)

    Gibelli, Daniele; Pucciarelli, Valentina; Cappella, Annalisa; Dolci, Claudia; Sforza, Chiarella

    2018-01-31

    Modern 3-dimensional (3D) image acquisition systems represent a crucial technologic development in facial anatomy because of their accuracy and precision. The recently introduced portable devices can improve facial databases by increasing the number of applications. In the present study, the VECTRA H1 portable stereophotogrammetric device was validated to verify its applicability to 3D facial analysis. Fifty volunteers underwent 4 facial scans using portable VECTRA H1 and static VECTRA M3 devices (2 for each instrument). Repeatability of linear, angular, surface area, and volume measurements was verified within the device and between devices using the Bland-Altman test and the calculation of absolute and relative technical errors of measurement (TEM and rTEM, respectively). In addition, the 2 scans obtained by the same device and the 2 scans obtained by different devices were registered and superimposed to calculate the root mean square (RMS; point-to-point) distance between the 2 surfaces. Most linear, angular, and surface area measurements had high repeatability in M3 versus M3, H1 versus H1, and M3 versus H1 comparisons (range, 82.2 to 98.7%; TEM range, 0.3 to 2.0 mm, 0.4° to 1.8°; rTEM range, 0.2 to 3.1%). In contrast, volumes and RMS distances showed evident differences in M3 versus M3 and H1 versus H1 comparisons and reached the maximum when scans from the 2 different devices were compared. The portable VECTRA H1 device proved reliable for assessing linear measurements, angles, and surface areas; conversely, the influence of involuntary facial movements on volumes and RMS distances was more important compared with the static device. Copyright © 2018 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  5. FASTBUS Readout Controller card for high speed data acquisition

    International Nuclear Information System (INIS)

    Zimmermann, S.

    1991-10-01

    This article describes a FASTBUS Readout Controller (FRC) for high speed data acquisition in FASTBUS based systems. The controller has two main interfaces: to FASTBUS and to a Readout Port. The FASTBUS interface performs FASTBUS master and slave operations at a maximum transfer rate exceeding 40 MBytes/s. The Readout Port can be adapted for a variety of protocols. Currently, it will be interfaced to a VME bus based processor with a VSB port. The on-board LR33000 embedded processor controls the readout, executing a list of operations download into its memory. It scans the FASTBUS modules and stores the data in a triple port DRAM (TPDRAM), through one of the Serial Access Memory (SAM) ports of the (TPDRAM). Later, it transfers this data to the readout port using the other SAM. The FRC also supports serial communication via RS232 and Ethernet interfaces. This device is intended for use in the data acquisition system at the Collider Detector at Fermilab. 5 refs., 3 figs

  6. Data acquisition and analysis at the Structural Biology Center

    International Nuclear Information System (INIS)

    Westbrook, M.L.; Coleman, T.A.; Daly, R.T.; Pflugrath, J.W.

    1996-01-01

    The Structural Biology Center (SBC), a national user facility for macromolecular crystallography located at Argonne National Laboratory's Advanced Photon Source, is currently being built and commissioned. SBC facilities include a bending-magnet beamline, an insertion-device beamline, laboratory and office space adjacent to the beamlines, and associated instrumentation, experimental apparatus, and facilities. SBC technical facilities will support anomalous dispersion phasing experiments, data collection from microcrystals, data collection from crystals with large molecular structures and rapid data collection from multiple related crystal structures for protein engineering and drug design. The SBC Computing Systems and Software Engineering Group is tasked with developing the SBC Control System, which includes computing systems, network, and software. The emphasis of SBC Control System development has been to provide efficient and convenient beamline control, data acquisition, and data analysis for maximal facility and experimenter productivity. This paper describes the SBC Control System development, specifically data acquisition and analysis at the SBC, and the development methods used to meet this goal

  7. A Study on the Effect of Communication Functioning of Smartphones on Information Acquisition: The Case of South Korea

    Directory of Open Access Journals (Sweden)

    Lee, Seungmin

    2016-09-01

    Full Text Available Smartphones have become one of the most prevalent information devices in the current information environment. Although many people use smartphones for communication and information acquisition, these two functions are closely related and cannot be separated. However, many studies have focused on identifying each function of a smartphone independently. There are few studies that investigate the relationships between communication and information acquisition functions on smartphones. This research empirically analyzed and identified the relationships between these two functions of smartphones by conducting a survey. The results of the analysis showed that the activities for information acquisition make differences in communication on a smartphone. People who want to acquire more information tend to use a smartphone for communication purposes. Besides, communication activities on a smartphone also affect the acquisition of information. In addition, communication activities on a smartphone also affect the establishment of interpersonal relationships that lead to the acquisition of more information. From these results, it is identified that communication activities and information acquisition are interrelated when satisfying the information needs of smartphone users. Especially, communication activities on a smartphone positively affect people's information activities and enhance information acquisition.

  8. Mergers and Acquisitions

    DEFF Research Database (Denmark)

    Risberg, Annette

    Introduction to the study of mergers and acquisitions. This book provides an understanding of the mergers and acquisitions process, how and why they occur, and also the broader implications for organizations. It presents issues including motives and planning, partner selection, integration......, employee experiences and communication. Mergers and acquisitions remain one of the most common forms of growth, yet they present considerable challenges for the companies and management involved. The effects on stakeholders, including shareholders, managers and employees, must be considered as well...... by editorial commentaries and reflects the important organizational and behavioural aspects which have often been ignored in the past. By providing this in-depth understanding of the mergers and acquisitions process, the reader understands not only how and why mergers and acquisitions occur, but also...

  9. [Wireless device for monitoring the patients with chronic disease].

    Science.gov (United States)

    Ciorap, R; Zaharia, D; Corciovă, C; Ungureanu, Monica; Lupu, R; Stan, A

    2008-01-01

    Remote monitoring of chronic diseases can improve health outcomes and potentially lower health care costs. The high number of the patients, suffering of chronically diseases, who wish to stay at home rather then in a hospital increasing the need of homecare monitoring and have lead to a high demand of wearable medical devices. Also, extended patient monitoring during normal activity has become a very important target. In this paper are presented the design of the wireless monitoring devices based on ultra low power circuits, high storage memory flash, bluetooth communication and the firmware for the management of the monitoring device. The monitoring device is built using an ultra low power microcontroller (MSP430 from Texas Instruments) that offers the advantage of high integration of some circuits. The custom made electronic boards used for biosignal acquisition are also included modules for storage device (SD/MMC card) with FAT32 file system and Bluetooth device for short-range communication used for data transmission between monitoring device and PC or PDA. The work was focused on design and implementation of an ultra low power wearable device able to acquire patient vital parameters, causing minimal discomfort and allowing high mobility. The proposed wireless device could be used as a warning system for monitoring during normal activity.

  10. Embedded Linux platform for data acquisition systems

    International Nuclear Information System (INIS)

    Patel, Jigneshkumar J.; Reddy, Nagaraj; Kumari, Praveena; Rajpal, Rachana; Pujara, Harshad; Jha, R.; Kalappurakkal, Praveen

    2014-01-01

    Highlights: • The design and the development of data acquisition system on FPGA based reconfigurable hardware platform. • Embedded Linux configuration and compilation for FPGA based systems. • Hardware logic IP core and its Linux device driver development for the external peripheral to interface it with the FPGA based system. - Abstract: This scalable hardware–software system is designed and developed to explore the emerging open standards for data acquisition requirement of Tokamak experiments. To address the future need for a scalable data acquisition and control system for fusion experiments, we have explored the capability of software platform using Open Source Embedded Linux Operating System on a programmable hardware platform such as FPGA. The idea was to identify the platform which can be customizable, flexible and scalable to support the data acquisition system requirements. To do this, we have selected FPGA based reconfigurable and scalable hardware platform to design the system with Embedded Linux based operating system for flexibility in software development and Gigabit Ethernet interface for high speed data transactions. The proposed hardware–software platform using FPGA and Embedded Linux OS offers a single chip solution with processor, peripherals such ADC interface controller, Gigabit Ethernet controller, memory controller amongst other peripherals. The Embedded Linux platform for data acquisition is implemented and tested on a Virtex-5 FXT FPGA ML507 which has PowerPC 440 (PPC440) [2] hard block on FPGA. For this work, we have used the Linux Kernel version 2.6.34 with BSP support for the ML507 platform. It is downloaded from the Xilinx [1] GIT server. Cross-compiler tool chain is created using the Buildroot scripts. The Linux Kernel and Root File System are configured and compiled using the cross-tools to support the hardware platform. The Analog to Digital Converter (ADC) IO module is designed and interfaced with the ML507 through Xilinx

  11. Embedded Linux platform for data acquisition systems

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Jigneshkumar J., E-mail: jjp@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India); Reddy, Nagaraj, E-mail: nagaraj.reddy@coreel.com [Sandeepani School of Embedded System Design, Bangalore, Karnataka (India); Kumari, Praveena, E-mail: praveena@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India); Rajpal, Rachana, E-mail: rachana@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India); Pujara, Harshad, E-mail: pujara@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India); Jha, R., E-mail: rjha@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India); Kalappurakkal, Praveen, E-mail: praveen.k@coreel.com [Sandeepani School of Embedded System Design, Bangalore, Karnataka (India)

    2014-05-15

    Highlights: • The design and the development of data acquisition system on FPGA based reconfigurable hardware platform. • Embedded Linux configuration and compilation for FPGA based systems. • Hardware logic IP core and its Linux device driver development for the external peripheral to interface it with the FPGA based system. - Abstract: This scalable hardware–software system is designed and developed to explore the emerging open standards for data acquisition requirement of Tokamak experiments. To address the future need for a scalable data acquisition and control system for fusion experiments, we have explored the capability of software platform using Open Source Embedded Linux Operating System on a programmable hardware platform such as FPGA. The idea was to identify the platform which can be customizable, flexible and scalable to support the data acquisition system requirements. To do this, we have selected FPGA based reconfigurable and scalable hardware platform to design the system with Embedded Linux based operating system for flexibility in software development and Gigabit Ethernet interface for high speed data transactions. The proposed hardware–software platform using FPGA and Embedded Linux OS offers a single chip solution with processor, peripherals such ADC interface controller, Gigabit Ethernet controller, memory controller amongst other peripherals. The Embedded Linux platform for data acquisition is implemented and tested on a Virtex-5 FXT FPGA ML507 which has PowerPC 440 (PPC440) [2] hard block on FPGA. For this work, we have used the Linux Kernel version 2.6.34 with BSP support for the ML507 platform. It is downloaded from the Xilinx [1] GIT server. Cross-compiler tool chain is created using the Buildroot scripts. The Linux Kernel and Root File System are configured and compiled using the cross-tools to support the hardware platform. The Analog to Digital Converter (ADC) IO module is designed and interfaced with the ML507 through Xilinx

  12. Development of a VME and CAMAC based data acquisition and transfer system for JT-60 control

    International Nuclear Information System (INIS)

    Totsuka, Toshiyuki

    1993-08-01

    Development of a VME and CAMAC based data acquisition and transfer system for JT-60 Control is reported. The present data acquisition and transfer system in JT-60 control is basically composed of CAMAC devices. Since the system equipped with 16-bit microcomputers was manufactured more than ten years ago, the performance and program development environment of the system are apparently worse than those of modern 32-bit microcomputers. To improve these disadvantages, a new data acquisition and transfer system using VME-based 32-bit microcomputers and CAMAC drivers is under design. Corresponding to this design, a CAMAC handler, which runs on the microcomputer, for the VME based CAMAC driver was newly developed. Moreover, the functions of the driver and data transfer performance of the VME and CAMAC complex system were tested. The test results shown that the VME based microcomputer and CAMAC serial driver can be applied for the fast and reliable acquisition and transfer system for JT-60 control. (author)

  13. New Approach Based on Compressive Sampling for Sample Rate Enhancement in DASs for Low-Cost Sensing Nodes

    Directory of Open Access Journals (Sweden)

    Francesco Bonavolontà

    2014-10-01

    Full Text Available The paper deals with the problem of improving the maximum sample rate of analog-to-digital converters (ADCs included in low cost wireless sensing nodes. To this aim, the authors propose an efficient acquisition strategy based on the combined use of high-resolution time-basis and compressive sampling. In particular, the high-resolution time-basis is adopted to provide a proper sequence of random sampling instants, and a suitable software procedure, based on compressive sampling approach, is exploited to reconstruct the signal of interest from the acquired samples. Thanks to the proposed strategy, the effective sample rate of the reconstructed signal can be as high as the frequency of the considered time-basis, thus significantly improving the inherent ADC sample rate. Several tests are carried out in simulated and real conditions to assess the performance of the proposed acquisition strategy in terms of reconstruction error. In particular, the results obtained in experimental tests with ADC included in actual 8- and 32-bits microcontrollers highlight the possibility of achieving effective sample rate up to 50 times higher than that of the original ADC sample rate.

  14. Bolometric Device Based on Fluxoid Quantization

    Science.gov (United States)

    Bonetti, Joseph A.; Kenyon, Matthew E.; Leduc, Henry G.; Day, Peter K.

    2010-01-01

    The temperature dependence of fluxoid quantization in a superconducting loop. The sensitivity of the device is expected to surpass that of other superconducting- based bolometric devices, such as superconducting transition-edge sensors and superconducting nanowire devices. Just as important, the proposed device has advantages in sample fabrication.

  15. Universal Safety Distance Alert Device for Road Vehicles

    Directory of Open Access Journals (Sweden)

    Matic Virant

    2016-04-01

    Full Text Available Driving with too short of a safety distance is a common problem in road traffic, often with traffic accidents as a consequence. Research has identified a lack of vehicle-mountable devices for alerting the drivers of trailing vehicles about keeping a sufficient safe distance. The principal requirements for such a device were defined. A conceptual study was performed in order to select the components for the integration of the device. Based on the results of this study, a working prototype of a flexible, self-contained device was designed, built and tested. The device is intended to be mounted on the rear of a vehicle. It uses radar as the primary distance sensor, assisted with a GPS receiver for velocity measurement. A Raspberry Pi single-board computer is used for data acquisition and processing. The alerts are shown on an LED-matrix display mounted on the rear of the host vehicle. The device software is written in Python and provides automatic operation without requiring any user intervention. The tests have shown that the device is usable on almost any motor vehicle and performs reliably in simulated and real traffic. The open issues and possibilities for future improvements are presented in the Discussion.

  16. Implementation of a versatile research data acquisition system using a commercially available medical ultrasound scanner

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian; Nikolov, Svetoslav Ivanov; Pedersen, Mads Møller

    2012-01-01

    to the clinic. The system consists of a standard PC equipped with a camera link and an ultrasound scanner equipped with a research interface. The ultrasound scanner is an easy-to-use imaging device that is capable of generating high-quality images. In addition to supporting the acquisition of multiple data...

  17. Evaluation of a New Technique for iFOBT Utilising a New Sample Collection Device with Increased Buffer Stability.

    Science.gov (United States)

    Bruns-Toepler, Markus; Hardt, Philip

    2017-07-01

    The aims of the present study were: (i) Evaluate specificity and sensitivity of Hb Smart enzyme-linked immunosorbent assay (ELISA) (ScheBo Biotech) compared to colonoscopy results and (ii) assess stability of a new sample collection device containing a newly formulated buffer to extract haemoglobin using buffer and stool samples spiked with defined concentrations of haemoglobin. Stool samples were quantified with the ELISA method. The stability of haemoglobin in the extraction buffer and in native stool samples, respectively, was determined daily by ELISA during storage for 5 days at 4°C and at room temperature after addition of haemoglobin. Haemoglobin ELISA had a sensitivity of 78.4% for detection of CRC with a specificity of 98%. Haemoglobin extracted in corresponding extraction buffer demonstrated stability throughout storage for 5 days at 4°C and at room temperature. Hb Smart represents a very promising tool for large-scale screening of CRC with regard to sample handling, stability and analysis of haemoglobin in faeces. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  18. Characteristics of a new fully programmable blood sampling device for monitoring blood radioactivity during PET

    International Nuclear Information System (INIS)

    Boellaard, R.; Lingen, A. van; Balen, S.C.M. van; Hoving, B.G.; Lammertsma, A.A.

    2001-01-01

    The first performance tests of a new fully programmable blood sampling device for monitoring blood radioactivity during positron emission tomography (PET) are described. Blood is withdrawn through 1-mm internal diameter tubing using an infusion pump which can be operated at rates varying from 0 to 600 ml/h. Activity in blood is measured by a 6-cm-thick bismuth germanate crystal connected to a photomultiplier tube and multichannel analyser (MCA) which are positioned within 6 cm lead shielding. Positioning of the tubing is an exact and simple procedure. The minimal readout time of the MCA is 1 s. Two independent energy windows can be set. Operation of the pump and MCA is fully controlled by a PC, i.e. sampling time, interval time and pump rate can be varied at any time during the PET scan by user-defined scripts. A number of characteristics of the new system were studied, such as sensitivity, dead time, linearity, effect of background radiation and pump rate as a function of input pressure. In addition, dispersion was measured as a function of pump rate. Finally, first clinical results were compared with manual samples. The sensitivity equalled 0.7 and 0.2 cps/Bq for 511- and 1022-keV 30% energy windows, respectively, and the system dead time was 500 ns. The system remained linear within 2% with activity concentrations up to 2.5 MBq/cc. Short-term reproducibility was better than 3% for a 1-h period. Long-term reproducibility was about 5% (1SD), which was mainly caused by variation in the diameter of the tubing. If the device was positioned in such a way that maximum shielding was directed towards the patient, the effects of background radiation from the patient on the measured activity concentration for clinically relevant conditions was minimal ( -1 were observed for pump rates higher than 300 ml/h, indicating that the system dispersion is small. Clinical data showed an excellent agreement to within 3% (1SD) between the results obtained with the new system and

  19. Collecting Ground Samples for Balloon-Borne Instruments

    Science.gov (United States)

    Jones, Jack; Zimmerman, Wayne; Wu, Jiunn Jenq

    2009-01-01

    A proposed system in a gondola containing scientific instruments suspended by a balloon over the surface of the Saturn moon Titan would quickly acquire samples of rock or ice from the ground below. Prototypes of a sample-collecting device that would be a major part of the system have been tested under cryogenic and non-cryogenic conditions on Earth. Systems like this one could also be used in non-cryogenic environments on Earth to collect samples of rock, soil, ice, mud, or other ground material from such inaccessible or hazardous locations as sites of suspected chemical spills or biological contamination. The sample-collecting device would be a harpoonlike device that would be connected to the balloon-borne gondola by a tether long enough to reach the ground. The device would be dropped from the gondola to acquire a sample, then would be reeled back up to the gondola, where the sample would be analyzed by the onboard instruments. Each prototype of the sample-collecting device has a sharp front (lower) end, a hollow core for retaining a sample, a spring for holding the sample in the hollow core, and a rear (upper) annular cavity for retaining liquid sample material. Aerodynamic fins at the rear help to keep the front end pointed downward. In tests, these prototype devices were dropped from various heights and used to gather samples of dry sand, moist sand, cryogenic water ice, and warmer water ice.

  20. Data acquisition and processing system for coincidence measurements

    International Nuclear Information System (INIS)

    Li Xu

    1990-07-01

    An instrument has been designed for the absolute measurement of radioactivity with 4πβ(PC)-γ coincidence. The instrument can be used as a standard device for the radioactivity measurement in metrology laboratories. Also it can be used in the nuclear science and engineering research for absolute measurement of nuclear decay rate. The control of the system dead time and coincidence resolving time is digitized. The precision can reach ±2 ns. For data acquisition and communication the normalizing GPIB interface system technique is adopted. The measuring error caused by this instrument itself can be better than ±0.02%

  1. An Investigation of Game-Embedded Handheld Devices to Enhance English Learning

    Science.gov (United States)

    Hung, Hui-Chun; Young, Shelley Shwu-Ching

    2015-01-01

    This study proposed and implemented a system combining the advantages of both educational games and wireless handheld technology to promote the interactive English learning in the classroom setting. An interactive English vocabulary acquisition board game was designed with the system being implemented on handheld devices. Thirty sixth-grade…

  2. On the development of automatic sample preparation devices

    International Nuclear Information System (INIS)

    Oesselmann, J.

    1987-01-01

    Modern mass spectrometers for stable isotope analysis offer accurate isotope ratio results from gaseous samples (CO 2 , N 2 , H 2 , SO 2 ) in a completely automated fashion. However, most samples of interest either are associated with contaminant gases or the gas has to be liberated by a chemical procedure prior to measurement. In most laboratories this sample preparation step is performed manually. As a consequence, sample throughput is rather low and - despite skilful operation - the preparation procedure varies slightly from one sample to the next affecting mainly the reproducibility of the data. (author)

  3. Fast-Acquisition/Weak-Signal-Tracking GPS Receiver for HEO

    Science.gov (United States)

    Wintemitz, Luke; Boegner, Greg; Sirotzky, Steve

    2004-01-01

    A report discusses the technical background and design of the Navigator Global Positioning System (GPS) receiver -- . a radiation-hardened receiver intended for use aboard spacecraft. Navigator is capable of weak signal acquisition and tracking as well as much faster acquisition of strong or weak signals with no a priori knowledge or external aiding. Weak-signal acquisition and tracking enables GPS use in high Earth orbits (HEO), and fast acquisition allows for the receiver to remain without power until needed in any orbit. Signal acquisition and signal tracking are, respectively, the processes of finding and demodulating a signal. Acquisition is the more computationally difficult process. Previous GPS receivers employ the method of sequentially searching the two-dimensional signal parameter space (code phase and Doppler). Navigator exploits properties of the Fourier transform in a massively parallel search for the GPS signal. This method results in far faster acquisition times [in the lab, 12 GPS satellites have been acquired with no a priori knowledge in a Low-Earth-Orbit (LEO) scenario in less than one second]. Modeling has shown that Navigator will be capable of acquiring signals down to 25 dB-Hz, appropriate for HEO missions. Navigator is built using the radiation-hardened ColdFire microprocessor and housing the most computationally intense functions in dedicated field-programmable gate arrays. The high performance of the algorithm and of the receiver as a whole are made possible by optimizing computational efficiency and carefully weighing tradeoffs among the sampling rate, data format, and data-path bit width.

  4. Status report of data acquisition

    International Nuclear Information System (INIS)

    Endo, Ichita

    1982-01-01

    The data acquisition system for the experiment with TRISTAN at KEK is discussed. For the standardization of the data bus, CAMAC-based system with possible improvement and FASTBUS being proposed by the US NIM committee were considered. The CAMAC has the disadvantages in the card size and the connectors. The card size is too small to house an intelligent circuit on a single board. The connectors cause most of troubles during the experiment. The FASTBUS is quite attractive from the viewpoint of the flexibility in bus speed and device size, although there is no commercially available FASTBUS device yet. It is not likely that other new data bus than CAMAC and FASTBUS is adopted by KEK for TRISTAN experiment. With respect to a standard microprocessor, an MC68000 (16 bit) has been picked up. The following items are being prepared by KEK to give support to users: i) the cross software of the MC68000 on the M200 H or PDP11, ii) the interface board for a personal computer equipped with a MC68000 chip to the FASTBUS and iii) a single board microprocessor module to be inserted in a FASTBUS crate. As for a host computer, a 32 bit minicomputer will be selected in 1982. (Ito, K.)

  5. CODA: A scalable, distributed data acquisition system

    International Nuclear Information System (INIS)

    Watson, W.A. III; Chen, J.; Heyes, G.; Jastrzembski, E.; Quarrie, D.

    1994-01-01

    A new data acquisition system has been designed for physics experiments scheduled to run at CEBAF starting in the summer of 1994. This system runs on Unix workstations connected via ethernet, FDDI, or other network hardware to multiple intelligent front end crates -- VME, CAMAC or FASTBUS. CAMAC crates may either contain intelligent processors, or may be interfaced to VME. The system is modular and scalable, from a single front end crate and one workstation linked by ethernet, to as may as 32 clusters of front end crates ultimately connected via a high speed network to a set of analysis workstations. The system includes an extensible, device independent slow controls package with drivers for CAMAC, VME, and high voltage crates, as well as a link to CEBAF accelerator controls. All distributed processes are managed by standard remote procedure calls propagating change-of-state requests, or reading and writing program variables. Custom components may be easily integrated. The system is portable to any front end processor running the VxWorks real-time kernel, and to most workstations supplying a few standard facilities such as rsh and X-windows, and Motif and socket libraries. Sample implementations exist for 2 Unix workstation families connected via ethernet or FDDI to VME (with interfaces to FASTBUS or CAMAC), and via ethernet to FASTBUS or CAMAC

  6. Quantitative Analysis of Heavy Metals in Water Based on LIBS with an Automatic Device for Sample Preparation

    International Nuclear Information System (INIS)

    Hu Li; Zhao Nanjing; Liu Wenqing; Meng Deshuo; Fang Li; Wang Yin; Yu Yang; Ma Mingjun

    2015-01-01

    Heavy metals in water can be deposited on graphite flakes, which can be used as an enrichment method for laser-induced breakdown spectroscopy (LIBS) and is studied in this paper. The graphite samples were prepared with an automatic device, which was composed of a loading and unloading module, a quantitatively adding solution module, a rapid heating and drying module and a precise rotating module. The experimental results showed that the sample preparation methods had no significant effect on sample distribution and the LIBS signal accumulated in 20 pulses was stable and repeatable. With an increasing amount of the sample solution on the graphite flake, the peak intensity at Cu I 324.75 nm accorded with the exponential function with a correlation coefficient of 0.9963 and the background intensity remained unchanged. The limit of detection (LOD) was calculated through linear fitting of the peak intensity versus the concentration. The LOD decreased rapidly with an increasing amount of sample solution until the amount exceeded 20 mL and the correlation coefficient of exponential function fitting was 0.991. The LOD of Pb, Ni, Cd, Cr and Zn after evaporating different amounts of sample solution on the graphite flakes was measured and the variation tendency of their LOD with sample solution amounts was similar to the tendency for Cu. The experimental data and conclusions could provide a reference for automatic sample preparation and heavy metal in situ detection. (paper)

  7. Acquisition and preparation of specimens of rock for large-scale testing

    International Nuclear Information System (INIS)

    Watkins, D.J.

    1981-01-01

    The techniques used for acquisition and preparation of large specimens of rock for laboratory testing depend upon the location of the specimen, the type of rock and the equipment available at the sampling site. Examples are presented to illustrate sampling and preparation techniques used for two large cylindrical samples of granitic material, one pervasively fractured and one containing a single fracture

  8. A Further Comparison of Manual Signing, Picture Exchange, and Speech-Generating Devices as Communication Modes for Children with Autism Spectrum Disorders

    Science.gov (United States)

    van der Meer, Larah; Sutherland, Dean; O'Reilly, Mark F.; Lancioni, Giulio E.; Sigafoos, Jeff

    2012-01-01

    We compared acquisition of, and preference for, manual signing (MS), picture exchange (PE), and speech-generating devices (SGDs) in four children with autism spectrum disorders (ASD). Intervention was introduced across participants in a non-concurrent multiple-baseline design and acquisition of the three communication modes was compared in an…

  9. Hard real-time quick EXAFS data acquisition with all open source software on a commodity personal computer

    International Nuclear Information System (INIS)

    So, I.; Siddons, D.P.; Caliebe, W.A.; Khalid, S.

    2007-01-01

    We describe here the data acquisition subsystem of the Quick EXAFS (QEXAFS) experiment at the National Synchrotron Light Source of Brookhaven National Laboratory. For ease of future growth and flexibility, almost all software components are open source with very active maintainers. Among them, Linux running on x86 desktop computer, RTAI for real-time response, COMEDI driver for the data acquisition hardware, Qt and PyQt for graphical user interface, PyQwt for plotting, and Python for scripting. The signal (A/D) and energy-reading (IK220 encoder) devices in the PCI computer are also EPICS enabled. The control system scans the monochromator energy through a networked EPICS motor. With the real-time kernel, the system is capable of deterministic data-sampling period of tens of micro-seconds with typical timing-jitter of several micro-seconds. At the same time, Linux is running in other non-real-time processes handling the user-interface. A modern Qt-based controls-frontend enhances productivity. The fast plotting and zooming of data in time or energy coordinates let the experimenters verify the quality of the data before detailed analysis. Python scripting is built-in for automation. The typical data-rate for continuous runs are around 10 M bytes/min

  10. Data Driven - Android based displays on data acquisition and system status

    CERN Document Server

    Canilho, Paulo

    2014-01-01

    For years, both hardware and software engineers have struggled with the acquisition of device information in a flexible and fast perspective, numerous devices cannot have their status quickly tested due to time limitation associated with the travelling to a computer terminal. For instance, in order to test a scintillator status, one has to inject beam into the device and quickly return to a terminal to see the results, this is not only time demanding but extremely inconvenient for the person responsible, it consumes time that would be used in more pressing matters. In this train of thoughts, the proposal of creating an interface to bring a stable, flexible, user friendly and data driven solution to this problem was created. Being the most common operative system for mobile display, the Android API proved to have the best efficient in financing, since it is based on an open source software, and in implementation difficulty since it’s backend development resides in JAVA calls and XML for visual representation...

  11. Comparing Book- and Tablet-Based Picture Activity Schedules: Acquisition and Preference.

    Science.gov (United States)

    Giles, Aimee; Markham, Victoria

    2017-09-01

    Picture activity schedules consist of a sequence of images representing the order of tasks for a person to complete. Although, picture activity schedules have traditionally been presented in a book format, recently picture activity schedules have been evaluated on technological devices such as an iPod™ touch. The present study compared the efficiency of picture activity schedule acquisition on book- and tablet-based modalities. In addition, participant preference for each modality was assessed. Three boys aged below 5 years with a diagnosis of autism participated. Participants were taught to follow the schedules using both modalities. Following mastery of each modality of picture activity schedule, a concurrent-chains preference assessment was conducted to evaluate participant preference for each modality. Differences in acquisition rates across the two modalities were marginal. Preference for book- or tablet-based schedules was idiosyncratic across participants.

  12. A Trimodal System for the Acquisition of Synchronous Echocardiography, Electrocardiography, and Seismocardiography Data

    Science.gov (United States)

    Wick, Carson A.; Su, Jin-Jyh; Brand, Oliver; McClellan, James H.; Bhatti, Pamela T.; Tridandapani, Srini

    2013-01-01

    A novel system was developed to acquire synchronous echocardiography, electrocardiography (EKG), and seismocardiography (SCG) data. The system was developed to facilitate the study of the relationship between the mechanical and electrical characteristics of the heart. The system has both a hardware and software component. The hardware component consists of an application-specific device designed and built to acquire both SCG and EKG signals simultaneously. The software component consists of a package developed to record and synchronize data from both the device and a clinical ultrasound machine. A feasibility test was performed by simultaneous acquisition of a synchronous dataset from a human subject. PMID:22255927

  13. DATA ACQUISITION (DAQ)

    CERN Multimedia

    Gerry Bauer

    The CMS Storage Manager System The tail-end of the CMS Data Acquisition System is the Storage Manger (SM), which collects output from the HLT and stages the data at Cessy for transfer to its ultimate home in the Tier-0 center. A SM system has been used by CMS for several years with the steadily evolving software within the XDAQ framework, but until relatively recently, only with provisional hardware. The SM is well known to much of the collaboration through the ‘MiniDAQ’ system, which served as the central DAQ system in 2007, and lives on in 2008 for dedicated sub-detector commissioning. Since March of 2008 a first phase of the final hardware was commissioned and used in CMS Global Runs. The system originally planned for 2008 aimed at recording ~1MB events at a few hundred Hz. The building blocks to achieve this are based on Nexsan's SATABeast storage array - a device  housing up to 40 disks of 1TB each, and possessing two controllers each capable of almost 200 MB/sec throughput....

  14. Information Quality and Risk Around Mergers and Acquisition ...

    African Journals Online (AJOL)

    We consolidate our understanding of the link between risk and quality of new around information intensive periods for a sample of 169 stocks from London Stock Exchange by using mergers and acquisitions announcements as a source of unscheduled news disclosure. We document that volatility of stock returns around ...

  15. Real-time data acquisition and parallel data processing solution for TJ-II Bolometer arrays diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Barrera, E. [Departamento de Sistemas Electronicos y de Control, Universidad Politecnica de Madrid, Crta. Valencia Km. 7, 28031 Madrid (Spain)]. E-mail: eduardo.barrera@upm.es; Ruiz, M. [Grupo de Investigacion en Instrumentacion y Acustica Aplicada, Universidad Politecnica de Madrid, Crta. Valencia Km. 7, 28031 Madrid (Spain); Lopez, S. [Departamento de Sistemas Electronicos y de Control, Universidad Politecnica de Madrid, Crta. Valencia Km. 7, 28031 Madrid (Spain); Machon, D. [Departamento de Sistemas Electronicos y de Control, Universidad Politecnica de Madrid, Crta. Valencia Km. 7, 28031 Madrid (Spain); Vega, J. [Asociacion EURATOM/CIEMAT para Fusion, 28040 Madrid (Spain); Ochando, M. [Asociacion EURATOM/CIEMAT para Fusion, 28040 Madrid (Spain)

    2006-07-15

    Maps of local plasma emissivity of TJ-II plasmas are determined using three-array cameras of silicon photodiodes (AXUV type from IRD). They have assigned the top and side ports of the same sector of the vacuum vessel. Each array consists of 20 unfiltered detectors. The signals from each of these detectors are the inputs to an iterative algorithm of tomographic reconstruction. Currently, these signals are acquired by a PXI standard system at approximately 50 kS/s, with 12 bits of resolution and are stored for off-line processing. A 0.5 s discharge generates 3 Mbytes of raw data. The algorithm's load exceeds the CPU capacity of the PXI system's controller in a continuous mode, making unfeasible to process the samples in parallel with their acquisition in a PXI standard system. A new architecture model has been developed, making possible to add one or several processing cards to a standard PXI system. With this model, it is possible to define how to distribute, in real-time, the data from all acquired signals in the system among the processing cards and the PXI controller. This way, by distributing the data processing among the system controller and two processing cards, the data processing can be done in parallel with the acquisition. Hence, this system configuration would be able to measure even in long pulse devices.

  16. A time-gated near-infrared spectroscopic imaging device for clinical applications.

    Science.gov (United States)

    Poulet, Patrick; Uhring, Wilfried; Hanselmann, Walter; Glazenborg, René; Nouizi, Farouk; Zint, Virginie; Hirschi, Werner

    2013-03-01

    A time-resolved, spectroscopic, diffuse optical tomography device was assembled for clinical applications like brain functional imaging. The entire instrument lies in a unique setup that includes a light source, an ultrafast time-gated intensified camera and all the electronic control units. The light source is composed of four near infrared laser diodes driven by a nanosecond electrical pulse generator working in a sequential mode at a repetition rate of 100 MHz. The light pulses are less than 80 ps FWHM. They are injected in a four-furcated optical fiber ended with a frontal light distributor to obtain a uniform illumination spot directed towards the head of the patient. Photons back-scattered by the subject are detected by the intensified CCD camera. There are resolved according to their time of flight inside the head. The photocathode is powered by an ultrafast generator producing 50 V pulses, at 100 MHz and a width corresponding to a 200 ps FWHM gate. The intensifier has been specially designed for this application. The whole instrument is controlled by an FPGA based module. All the acquisition parameters are configurable via software through an USB plug and the image data are transferred to a PC via an Ethernet link. The compactness of the device makes it a perfect device for bedside clinical applications. The instrument will be described and characterized. Preliminary data recorded on test samples will be presented.

  17. A low-power bio-potential acquisition system with flexible PDMS dry electrodes for portable ubiquitous healthcare applications.

    Science.gov (United States)

    Chen, Chih-Yuan; Chang, Chia-Lin; Chang, Chih-Wei; Lai, Shin-Chi; Chien, Tsung-Fu; Huang, Hong-Yi; Chiou, Jin-Chern; Luo, Ching-Hsing

    2013-03-04

    This work describes a bio-potential acquisition system for portable ubiquitous healthcare applications using flexible polydimethylsiloxane dry electrodes (FPDEs) and a low-power recording circuit. This novel FPDE used Au as the skin contact layer, which was made using a CO2 laser and replica method technology. The FPDE was revised from a commercial bio-potential electrode with a conductive snap using dry electrodes rather than wet electrodes that proposed reliable and robust attachment for the purpose of measurement, and attaching velcro made it wearable on the forearm for bio-potential applications. Furthermore, this study proposes a recording device to store bio-potential signal data and provides portability and low-power consumption for the proposed acquisition system. To acquire differential bio-potentials, such as electrocardiogram (ECG) signals, the proposed recording device includes a low-power front-end acquisition chip fabricated using a complementary metal-oxide-semiconductor (CMOS) process, a commercial microcontroller (MSP430F149), and a secure digital (SD) card for portable healthcare applications. The proposed system can obtain ECG signals efficiently and are comfortable to the skin. The power consumption of the system is about 85 mW for continuous working over a 3 day period with two AA batteries. It can also be used as a compact Holter ECG system.

  18. Development of data acquisition and analysis system for the nuclear vessel weld

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. P.; Park, C. H.; Lim, H. T.; Noh, H. C. [Research Institute of KAITEC, Taejeon (Korea)

    2000-03-01

    The objective of this project is to develop an automated ultrasonic data acquisition and data analysis system to examine heavy vessel welds. In order to examine nuclear vessel welds including reactor pressure vessel(RPV), huge amount of ultrasonic data from 6 channels should be able to be on-line processed. In addition, ultrasonic transducer scanning device should be remotely controlled, because working place is high radiation area. This kind of an automated ultrasonic testing equipment has not been developed domestically yet. In order to develop an automated ultrasonic testing system, RPV ultrasonic testing equipments developed in foreign countries were investigated and the capability of high speed ultrasonic signal processing hardwares was analyzed. In this study, ultrasonic signal processing system was designed. And also, ultrasonic data acquisition software was developed. 11 refs., 6 figs. (Author)

  19. Patient-adapted reconstruction and acquisition dynamic imaging method (PARADIGM) for MRI

    International Nuclear Information System (INIS)

    Aggarwal, Nitin; Bresler, Yoram

    2008-01-01

    Dynamic magnetic resonance imaging (MRI) is a challenging problem because the MR data acquisition is often not fast enough to meet the combined spatial and temporal Nyquist sampling rate requirements. Current approaches to this problem include hardware-based acceleration of the acquisition, and model-based image reconstruction techniques. In this paper we propose an alternative approach, called PARADIGM, which adapts both the acquisition and reconstruction to the spatio-temporal characteristics of the imaged object. The approach is based on time-sequential sampling theory, addressing the problem of acquiring a spatio-temporal signal under the constraint that only a limited amount of data can be acquired at a time instant. PARADIGM identifies a model class for the particular imaged object using a scout MR scan or auxiliary data. This object-adapted model is then used to optimize MR data acquisition, such that the imaging constraints are met, acquisition speed requirements are minimized, essentially perfect reconstruction of any object in the model class is guaranteed, and the inverse problem of reconstructing the dynamic object has a condition number of one. We describe spatio-temporal object models for various dynamic imaging applications including cardiac imaging. We present the theory underlying PARADIGM and analyze its performance theoretically and numerically. We also propose a practical MR imaging scheme for 2D dynamic cardiac imaging based on the theory. For this application, PARADIGM is predicted to provide a 10–25 × acceleration compared to the optimal non-adaptive scheme. Finally we present generalized optimality criteria and extend the scheme to dynamic imaging with three spatial dimensions

  20. 2017 NAIP Acquisition Map

    Data.gov (United States)

    Farm Service Agency, Department of Agriculture — Planned States for 2017 NAIP acquisition and acquisition status layer (updated daily). Updates to the acquisition seasons may be made during the season to...

  1. Efficient Lossy Compression for Compressive Sensing Acquisition of Images in Compressive Sensing Imaging Systems

    Directory of Open Access Journals (Sweden)

    Xiangwei Li

    2014-12-01

    Full Text Available Compressive Sensing Imaging (CSI is a new framework for image acquisition, which enables the simultaneous acquisition and compression of a scene. Since the characteristics of Compressive Sensing (CS acquisition are very different from traditional image acquisition, the general image compression solution may not work well. In this paper, we propose an efficient lossy compression solution for CS acquisition of images by considering the distinctive features of the CSI. First, we design an adaptive compressive sensing acquisition method for images according to the sampling rate, which could achieve better CS reconstruction quality for the acquired image. Second, we develop a universal quantization for the obtained CS measurements from CS acquisition without knowing any a priori information about the captured image. Finally, we apply these two methods in the CSI system for efficient lossy compression of CS acquisition. Simulation results demonstrate that the proposed solution improves the rate-distortion performance by 0.4~2 dB comparing with current state-of-the-art, while maintaining a low computational complexity.

  2. 30 CFR 71.201 - Sampling; general requirements.

    Science.gov (United States)

    2010-07-01

    ... MINES Sampling Procedures § 71.201 Sampling; general requirements. (a) Each operator shall take... required by this part with a sampling device approved by the Secretary and the Secretary of Health and Human Services under part 74 (Coal Mine Dust Personal Sampler Units) of this title. (b) Sampling devices...

  3. Fluoroscopic dose reduction by acquisition frame rate reduction and image processing

    International Nuclear Information System (INIS)

    Fritz, S.L.; Mirvis, S.E.; Pals, S.O.

    1986-01-01

    A new design for fluoroscopic exposure reduction incorporates pulsed x-ray exposure, progressive scan video acquisition at frame rates below 30 Hz, interlaced video display at 30 Hz, and a video rate image processing. To evaluate this design, a variety of phantom systems have been developed to measure the impact of low frame rate pulsed digital fluoroscopy on the performance of several clinical tasks (e.g., catheter placement). The authors are currently using these phantoms with a digital fluoroscopy system using continuous x-ray, interlaced video acquisition and variable acquisition frame rate. The design of their target digital fluoroscopic system, sample image sequences, and the results of some preliminary phantom studies are reported

  4. Crystal ball data acquisition system

    International Nuclear Information System (INIS)

    Chestnut, R.; Kiesling, C.; Bloom, E.; Bulos, F.; Gaiser, J.; Godfrey, G.; Oreglia, M.; Partridge, R.; Peck, C.; Porter, F.; Aschman, D.; Cavali-Sforza, M.; Coyne, D.; Sadrozinski, H.; Kollmann, W.; Richardson, M.

    1979-01-01

    The data acquisition system for the Crystal Ball project at SLAC is described. A PDP-11/t55 using RSX-11M connected to the SLAC Triplex is the basis of the system. A ''physics pipeline'' allows physicists to write their own equipment-monitoring or physics tasks which require event sampling. As well, an interactive analysis package (MULTI) is in the pipeline. Histogram collection and display on the PDP are implemented using the Triplex histogramming package. Various interactive event displays are also implemented

  5. D Models for All: Low-Cost Acquisition Through Mobile Devices in Comparison with Image Based Techniques. Potentialities and Weaknesses in Cultural Heritage Domain

    Science.gov (United States)

    Santagati, C.; Lo Turco, M.; Bocconcino, M. M.; Donato, V.; Galizia, M.

    2017-11-01

    Nowadays, 3D digital imaging proposes effective solutions for preserving the expression of human creativity across the centuries, as well as is a great tool to guarantee global dissemination of knowledge and wide access to these invaluable resources of the past. Nevertheless, in several cases, a massive digitalisation of cultural heritage items (from the archaeological site up to the monument and museum collections) could be unworkable due to the still high costs in terms of equipment and human resources: 3D acquisition technologies and the need of skilled team within cultural institutions. Therefore, it is necessary to explore new possibilities offered by growing technologies: the lower costs of these technologies as well as their attractive visual quality constitute a challenge for researchers. Besides these possibilities, it is also important to consider how information is spread through graphic representation of knowledge. The focus of this study is to explore the potentialities and weaknesses of a newly released low cost device in the cultural heritage domain, trying to understand its effective usability in museum collections. The aim of the research is to test their usability, critically analysing the final outcomes of this entry level technology in relation to the other better assessed low cost technologies for 3D scanning, such as Structure from Motion (SfM) techniques (also produced by the same device) combined with dataset generated by a professional digital camera. The final outcomes were compared in terms of quality definition, time processing and file size. The specimens of the collections of the Civic Museum Castello Ursino in Catania have been chosen as the site of experimentation.

  6. Acquisition And Utilisation Of Human Resources In Public ...

    African Journals Online (AJOL)

    The study examined the acquisition and utilisation of human resources in public secondary schools for students with special needs in Oyo State. The study employed a descriptive research design. The entire 196 teachers and 16 supportive staff formed the sample. The research instrument for the study was a questionnaire ...

  7. Data acquisition

    International Nuclear Information System (INIS)

    Clout, P.N.

    1982-01-01

    Data acquisition systems are discussed for molecular biology experiments using synchrotron radiation sources. The data acquisition system requirements are considered. The components of the solution are described including hardwired solutions and computer-based solutions. Finally, the considerations for the choice of the computer-based solution are outlined. (U.K.)

  8. Low-power analog integrated circuits for wireless ECG acquisition systems.

    Science.gov (United States)

    Tsai, Tsung-Heng; Hong, Jia-Hua; Wang, Liang-Hung; Lee, Shuenn-Yuh

    2012-09-01

    This paper presents low-power analog ICs for wireless ECG acquisition systems. Considering the power-efficient communication in the body sensor network, the required low-power analog ICs are developed for a healthcare system through miniaturization and system integration. To acquire the ECG signal, a low-power analog front-end system, including an ECG signal acquisition board, an on-chip low-pass filter, and an on-chip successive-approximation analog-to-digital converter for portable ECG detection devices is presented. A quadrature CMOS voltage-controlled oscillator and a 2.4 GHz direct-conversion transmitter with a power amplifier and upconversion mixer are also developed to transmit the ECG signal through wireless communication. In the receiver, a 2.4 GHz fully integrated CMOS RF front end with a low-noise amplifier, differential power splitter, and quadrature mixer based on current-reused folded architecture is proposed. The circuits have been implemented to meet the specifications of the IEEE 802.15.4 2.4 GHz standard. The low-power ICs of the wireless ECG acquisition systems have been fabricated using a 0.18 μm Taiwan Semiconductor Manufacturing Company (TSMC) CMOS standard process. The measured results on the human body reveal that ECG signals can be acquired effectively by the proposed low-power analog front-end ICs.

  9. Comparative A/B testing a mobile data acquisition app for hydrogeochemistry

    Science.gov (United States)

    Klump, Jens; Golodoniuc, Pavel; Reid, Nathan; Gray, David; Ross, Shawn

    2015-04-01

    In the context of a larger study on the Capricorn Orogen of Western Australia, the CSIRO Mineral Discovery Program is conducting a regional study of the hydrogeochemistry on water from agricultural and other bores. Over time, the sampling process was standardised and a form for capturing metadata and data from initial measurements was developed. In 2014 an extensive technology review was conducted with an aim to automate field data acquisition process. A prototype hydrogeochemistry data capture form was implemented as a mobile application for Windows Mobile devices. This version of the software was a standalone application with an interface to export data as CSV files. A second candidate version of the hydrogeochemistry data capture form was implemented as an Android mobile application in the FAIMS framework. FAIMS is a framework for mobile field data capture, originally developed by at the University of New South Wales for archaeological field data collection. A benefit of the FAIMS application was the ability to associate photographs taken with the device's embedded camera with the captured data. FAIMS also allows networked collaboration within a field team, using the mobile applications as asynchronous rich clients. The network infrastructure can be installed in the field ("FAIMS in a Box") to supply data synchronisation, backup and transfer. This aspect will be tested in the next field season. A benefit of the FAIMS application was the ability to associate photographs taken with the device's embedded camera with the captured data. Having two data capture applications available allowed us to conduct an A/B test, comparing two different implementations for the same task. Both applications were trialled in the field by different field crews and user feedback will be used to improve the usability of the app for the next field season. A key learning was that the ergonomics of the app is at paramount importance to gain the user acceptance. This extends from general

  10. Reducing acquisition times in multidimensional NMR with a time-optimized Fourier encoding algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zhiyong [Department of Chemical Physics, Weizmann Institute of Science, Rehovot 76100 (Israel); Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, Fujian 361005 (China); Smith, Pieter E. S.; Frydman, Lucio, E-mail: lucio.frydman@weizmann.ac.il [Department of Chemical Physics, Weizmann Institute of Science, Rehovot 76100 (Israel)

    2014-11-21

    Speeding up the acquisition of multidimensional nuclear magnetic resonance (NMR) spectra is an important topic in contemporary NMR, with central roles in high-throughput investigations and analyses of marginally stable samples. A variety of fast NMR techniques have been developed, including methods based on non-uniform sampling and Hadamard encoding, that overcome the long sampling times inherent to schemes based on fast-Fourier-transform (FFT) methods. Here, we explore the potential of an alternative fast acquisition method that leverages a priori knowledge, to tailor polychromatic pulses and customized time delays for an efficient Fourier encoding of the indirect domain of an NMR experiment. By porting the encoding of the indirect-domain to the excitation process, this strategy avoids potential artifacts associated with non-uniform sampling schemes and uses a minimum number of scans equal to the number of resonances present in the indirect dimension. An added convenience is afforded by the fact that a usual 2D FFT can be used to process the generated data. Acquisitions of 2D heteronuclear correlation NMR spectra on quinine and on the anti-inflammatory drug isobutyl propionic phenolic acid illustrate the new method's performance. This method can be readily automated to deal with complex samples such as those occurring in metabolomics, in in-cell as well as in in vivo NMR applications, where speed and temporal stability are often primary concerns.

  11. Reducing acquisition times in multidimensional NMR with a time-optimized Fourier encoding algorithm

    International Nuclear Information System (INIS)

    Zhang, Zhiyong; Smith, Pieter E. S.; Frydman, Lucio

    2014-01-01

    Speeding up the acquisition of multidimensional nuclear magnetic resonance (NMR) spectra is an important topic in contemporary NMR, with central roles in high-throughput investigations and analyses of marginally stable samples. A variety of fast NMR techniques have been developed, including methods based on non-uniform sampling and Hadamard encoding, that overcome the long sampling times inherent to schemes based on fast-Fourier-transform (FFT) methods. Here, we explore the potential of an alternative fast acquisition method that leverages a priori knowledge, to tailor polychromatic pulses and customized time delays for an efficient Fourier encoding of the indirect domain of an NMR experiment. By porting the encoding of the indirect-domain to the excitation process, this strategy avoids potential artifacts associated with non-uniform sampling schemes and uses a minimum number of scans equal to the number of resonances present in the indirect dimension. An added convenience is afforded by the fact that a usual 2D FFT can be used to process the generated data. Acquisitions of 2D heteronuclear correlation NMR spectra on quinine and on the anti-inflammatory drug isobutyl propionic phenolic acid illustrate the new method's performance. This method can be readily automated to deal with complex samples such as those occurring in metabolomics, in in-cell as well as in in vivo NMR applications, where speed and temporal stability are often primary concerns

  12. Fast charge digitizer and digital data acquisition system for measuring time varying radiation fields

    International Nuclear Information System (INIS)

    Lee, T.R.; Schneider, R.H.; Wyatt, J.L.

    1976-01-01

    A radiation measuring instrument including a fast charge digitizer and a digital data acquisition system has been developed. The fast charge digitizer includes a charge integrator connected to a conventional ionization chamber which generates an output current in proportion to ionizing radiation exposure rate. The charge integrator has an output connected to a comparator which is switched from a high state to a low state when the output of the integrator goes above the comparator threshold. The comparator output is connected to a bistable multivibrator consisting of two non-retriggerable one shot multivibrators connected in a feedback configuration. As long as the comparator output is in the low state, the bistable multivibrator generates a train of pluses which are fed back through an analog switch and a high megohm resistance to the input of the integrator. This feedback is negative and has the effect of removing the charge from the integrating capacitor, thus causing the integrator output eventually to drop below the comparator threshold. When this occurs the comparator output returns to the high state and the bistable multivibrator ceases to generate output pulses. An output terminal is connected between the bistable multivibrator and the analog switch and feeds a train of pulses proportional to the amount of charge generated by the multivibrator output voltage and the high megohm resistance to a counter connected to a random access memory device. The output pulses are counted for a predetermined time and then stored in one of the data locations of the random access memory device. The counter is then reset and a further predetermined sample period is counted. This continues until all of the locations in the random access memory device are filled and then the data is read from the random access memory device

  13. Theoretical basis, application, reliability, and sample size estimates of a Meridian Energy Analysis Device for Traditional Chinese Medicine Research

    Directory of Open Access Journals (Sweden)

    Ming-Yen Tsai

    Full Text Available OBJECTIVES: The Meridian Energy Analysis Device is currently a popular tool in the scientific research of meridian electrophysiology. In this field, it is generally believed that measuring the electrical conductivity of meridians provides information about the balance of bioenergy or Qi-blood in the body. METHODS AND RESULTS: PubMed database based on some original articles from 1956 to 2014 and the authoŕs clinical experience. In this short communication, we provide clinical examples of Meridian Energy Analysis Device application, especially in the field of traditional Chinese medicine, discuss the reliability of the measurements, and put the values obtained into context by considering items of considerable variability and by estimating sample size. CONCLUSION: The Meridian Energy Analysis Device is making a valuable contribution to the diagnosis of Qi-blood dysfunction. It can be assessed from short-term and long-term meridian bioenergy recordings. It is one of the few methods that allow outpatient traditional Chinese medicine diagnosis, monitoring the progress, therapeutic effect and evaluation of patient prognosis. The holistic approaches underlying the practice of traditional Chinese medicine and new trends in modern medicine toward the use of objective instruments require in-depth knowledge of the mechanisms of meridian energy, and the Meridian Energy Analysis Device can feasibly be used for understanding and interpreting traditional Chinese medicine theory, especially in view of its expansion in Western countries.

  14. Speech-Generating Devices versus Manual Signing for Children with Developmental Disabilities

    Science.gov (United States)

    van der Meer, Larah; Kagohara, Debora; Achmadi, Donna; O'Reilly, Mark F.; Lancioni, Giulio E.; Sutherland, Dean; Sigafoos, Jeff

    2012-01-01

    We compared speed of acquisition and preference for using a speech-generating device (SGD) versus manual signing (MS) as augmentative and alternative communication (AAC) options. Four children with developmental disabilities (DD), aged 5-10 years, were taught to request preferred objects using an iPod[R]-based SGD and MS. Intervention was…

  15. Data Acquisition with GPUs: The DAQ for the Muon $g$-$2$ Experiment at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Gohn, W. [Kentucky U.

    2016-11-15

    Graphical Processing Units (GPUs) have recently become a valuable computing tool for the acquisition of data at high rates and for a relatively low cost. The devices work by parallelizing the code into thousands of threads, each executing a simple process, such as identifying pulses from a waveform digitizer. The CUDA programming library can be used to effectively write code to parallelize such tasks on Nvidia GPUs, providing a significant upgrade in performance over CPU based acquisition systems. The muon $g$-$2$ experiment at Fermilab is heavily relying on GPUs to process its data. The data acquisition system for this experiment must have the ability to create deadtime-free records from 700 $\\mu$s muon spills at a raw data rate 18 GB per second. Data will be collected using 1296 channels of $\\mu$TCA-based 800 MSPS, 12 bit waveform digitizers and processed in a layered array of networked commodity processors with 24 GPUs working in parallel to perform a fast recording of the muon decays during the spill. The described data acquisition system is currently being constructed, and will be fully operational before the start of the experiment in 2017.

  16. Evaluation of Acquisition Strategies for Image-Based Construction Site Monitoring

    Science.gov (United States)

    Tuttas, S.; Braun, A.; Borrmann, A.; Stilla, U.

    2016-06-01

    Construction site monitoring is an essential task for keeping track of the ongoing construction work and providing up-to-date information for a Building Information Model (BIM). The BIM contains the as-planned states (geometry, schedule, costs, ...) of a construction project. For updating, the as-built state has to be acquired repeatedly and compared to the as-planned state. In the approach presented here, a 3D representation of the as-built state is calculated from photogrammetric images using multi-view stereo reconstruction. On construction sites one has to cope with several difficulties like security aspects, limited accessibility, occlusions or construction activity. Different acquisition strategies and techniques, namely (i) terrestrial acquisition with a hand-held camera, (ii) aerial acquisition using a Unmanned Aerial Vehicle (UAV) and (iii) acquisition using a fixed stereo camera pair at the boom of the crane, are tested on three test sites. They are assessed considering the special needs for the monitoring tasks and limitations on construction sites. The three scenarios are evaluated based on the ability of automation, the required effort for acquisition, the necessary equipment and its maintaining, disturbance of the construction works, and on the accuracy and completeness of the resulting point clouds. Based on the experiences during the test cases the following conclusions can be drawn: Terrestrial acquisition has the lowest requirements on the device setup but lacks on automation and coverage. The crane camera shows the lowest flexibility but the highest grade of automation. The UAV approach can provide the best coverage by combining nadir and oblique views, but can be limited by obstacles and security aspects. The accuracy of the point clouds is evaluated based on plane fitting of selected building parts. The RMS errors of the fitted parts range from 1 to a few cm for the UAV and the hand-held scenario. First results show that the crane camera

  17. EVALUATION OF ACQUISITION STRATEGIES FOR IMAGE-BASED CONSTRUCTION SITE MONITORING

    Directory of Open Access Journals (Sweden)

    S. Tuttas

    2016-06-01

    Full Text Available Construction site monitoring is an essential task for keeping track of the ongoing construction work and providing up-to-date information for a Building Information Model (BIM. The BIM contains the as-planned states (geometry, schedule, costs, ... of a construction project. For updating, the as-built state has to be acquired repeatedly and compared to the as-planned state. In the approach presented here, a 3D representation of the as-built state is calculated from photogrammetric images using multi-view stereo reconstruction. On construction sites one has to cope with several difficulties like security aspects, limited accessibility, occlusions or construction activity. Different acquisition strategies and techniques, namely (i terrestrial acquisition with a hand-held camera, (ii aerial acquisition using a Unmanned Aerial Vehicle (UAV and (iii acquisition using a fixed stereo camera pair at the boom of the crane, are tested on three test sites. They are assessed considering the special needs for the monitoring tasks and limitations on construction sites. The three scenarios are evaluated based on the ability of automation, the required effort for acquisition, the necessary equipment and its maintaining, disturbance of the construction works, and on the accuracy and completeness of the resulting point clouds. Based on the experiences during the test cases the following conclusions can be drawn: Terrestrial acquisition has the lowest requirements on the device setup but lacks on automation and coverage. The crane camera shows the lowest flexibility but the highest grade of automation. The UAV approach can provide the best coverage by combining nadir and oblique views, but can be limited by obstacles and security aspects. The accuracy of the point clouds is evaluated based on plane fitting of selected building parts. The RMS errors of the fitted parts range from 1 to a few cm for the UAV and the hand-held scenario. First results show that the crane

  18. Well logging. Acquisition and applications; Diagraphies. Acquisition et applications

    Energy Technology Data Exchange (ETDEWEB)

    Serra, O.; Serra, L.

    2001-07-01

    This reference book on wire-line and LWD well logging covers all geophysical methods of underground survey in a synthetic, visual and dynamical way. It treats of: the physical principle of well logging measurements, the different types of existing probes, the factors that can influence the measurements, and the applications of these measurements. The following well-logging methods are reviewed: resistivity; electromagnetic wave propagation; magnetic susceptibility and magnetic field; spontaneous potential; nuclear logging: natural gamma radioactivity, density logging, photoelectric index, neutron emission probes, hydrogen index or neutron porosity, neutron induced gamma spectroscopy, neutron relaxation time, NMR; acoustic measurements: sonic logging, seismic profiles; texture, structure and stratigraphy data acquisition; borehole diameter measurement; temperature measurement; wire sampling methods; place and role of well-logging in petroleum exploration; well-logging programs. (J.S.)

  19. Data Acquisition System

    International Nuclear Information System (INIS)

    Cirstea, C.D.; Buda, S.I.; Constantin, F.

    2005-01-01

    This paper deals with a multi parametric acquisition system developed for a four input Analog to Digital Converter working in CAMAC Standard. The acquisition software is built in MS Visual C++ on a standard PC with a USB interface. It has a visual interface which permits Start/Stop of the acquisition, setting the type of acquisition (True/Live time), the time and various menus for primary data acquisition. The spectrum is dynamically visualized with a moving cursor indicating the content and position. The microcontroller PIC16C765 is used for data transfer from ADC to PC; The microcontroller and the software create an embedded system which emulates the CAMAC protocol programming the 4 input ADC for operating modes ('zero suppression', 'addressed' and 'sequential') and handling the data transfers from ADC to its internal memory. From its memory the data is transferred into the PC by the USB interface. The work is in progress. (authors)

  20. Data acquisition system

    International Nuclear Information System (INIS)

    Cirstea, D.C.; Buda, S.I.; Constantin, F.

    2005-01-01

    The topic of this paper deals with a multi parametric acquisition system developed around a four input Analog to Digital Converter working in CAMAC Standard. The acquisition software is built in MS Visual C++ on a standard PC with a USB interface. It has a visual interface which permits Start/Stop of the acquisition, setting the type of acquisition (True/Live time), the time and various menus for primary data acquisition. The spectrum is dynamically visualized with a moving cursor indicating the content and position. The microcontroller PIC16C765 is used for data transfer from ADC to PC; The microcontroller and the software create an embedded system which emulates the CAMAC protocol programming, the 4 input ADC for operating modes ('zero suppression', 'addressed' and 'sequential') and handling the data transfers from ADC to its internal memory. From its memory the data is transferred into the PC by the USB interface. The work is in progress. (authors)