Models in detail. Analysis and assessment of models and methods to determine the air quality along highways; Modellen onder de loep. Analyse en beoordeling van modellen en methoden voor de bepaling van de luchtkwaliteit langs snelwegen  

Energy Technology Data Exchange (ETDEWEB)

An overview is given of several computer models in use in the Netherlands to determine and analyze the quality of air and the effect of air pollution abatement measures. [Dutch] Voor het vaststellen van de luchtkwaliteit of het bepalen van het effect van emissiereducerende maatregelen op die luchtkwaliteit zijn in ons land meerdere computermodellen beschikbaar. In het kader van het Vooronderzoek Innovatieprogramma Luchtkwaliteit (VIPL) wilde het ministerie van Verkeer en Waterstaat meer inzicht in de betrouwbaarheid en specifieke eigenschappen van deze modellen. Deze studie geeft daarom een overzicht en analyse van de verschillen, overeenkomsten en voor- en nadelen van de meest gangbare Nederlandse computermodellen om de luchtkwaliteit rond snelwegen te bepalen. Dit zijn: Het Voorspellingssysteem Luchtkwaliteit Wegtraces (VLW); CAR-II; Het TNO-verkeersmodel; Het Heaven-model van ...

2003-12-15

2

IEA Annex 27. Assessment of air quality, comfort and sound of ventilation systems in houses; IEA Annex 27. Beoordeling van woningventilatiesystemen op luchtkwaliteit, comfort en geluid  

Energy Technology Data Exchange (ETDEWEB)

In the international study of IEA Annex 27 `Demonstration and evaluation of domestic ventilation systems` a number of simple tools to gain insight into the characteristics of ventilation systems for dwellings are presented. The assessment is made with respect to e.g. indoor air quality, comfort, noise, energy, costs and reliability. In three articles the results of Annex 27 will be discussed. In the first article background information of IEA Annex 27 was given as well as applications in the Netherlands. In this second article attention is paid to the assessment models (`simplified tools`) for indoor air quality, thermal comfort and noise. 6 refs.

1999-09-01

3

Calculation of the air flow, air quality and the thermal comfort in an operating room. Berekening van de luchtstroming, luchtkwaliteit en het thermisch comfort in een operatiekamer  

Energy Technology Data Exchange (ETDEWEB)

By means of a numerical simulation model (PHOENICS) the air flow and the distribution of the air concentration in an operating room of an hospital have been calculated. Comparisons were made for 11 different conditions (m[sup 3]/h air flow, speed of the air supply in the centre, the middle and outside of the room), of which six cases are discussed in this article, in order to optimize the air flow pattern in the room. The calculations were conducted for the so-called Howorth system. It is shown that the inlet velocity profile with a higher inlet velocity in the center zone of the hood gives the best results. The calculated results were validated by some measurements and experiments with smoke. 7 figs., 2 tabs., 8 refs.

1993-04-01

4

High air quality and low energy consumption. Performance of hybrid ventilation with CO2-sensors; Hoge luchtkwaliteit en lage energiebesparing. Goede prestaties van hybride ventilatie met CO2-sensoren  

Energy Technology Data Exchange (ETDEWEB)

The school building complex Waterland in The Hague, Netherlands, was built with a hybrid ventilation system. The indoor environment and energy consumption were monitored for one year. Air quality and thermal comfort are of a high quality and the consumption of energy for heating is circa 35% lower than normal. The Waterland project was one of eight demonstration projects, carried out within the framework of the ECBS-Annex 35: Hybrid ventilation in New and retrofitted Office Buildings. ECBS stands for the IEA-program Energy Conservation in Buildings and Community Systems. [Dutch] In ECBCs-annex 35 (ECBS staat voor het IEA-programma Energy Conservation in Buildings and Community Systems) is uitgebreid onderzoek gedaan naar hybride ventilatiesystemen in kantoren en scholen. Dit project heeft geleid tot acht internationale voorbeeldprojecten, waarvan scholencomplex Waterland te Den Haag er een van is. Het scholencomplex is in 2003 opgeleverd met een hybride ventilatiesysteem. Het ...

2005-11-01

5

A healthy climate for the Printer house. Indoor climate improved by means of adjucting the air conditioning installation; Een gezond klimaat voor het Printerhuis. Binnenklimaat verbetert dankzij aanpassing LBK  

Energy Technology Data Exchange (ETDEWEB)

In the first part of the nineties many office buildings were equipped with indoor climate installations which do not meet present standards. Several options are available to improve such installations for ventilation capacity, cooling capacity, thermal comfort and air quality. One of the options concern the installation of an air conditioner in combination with heat recovery. In this article attention is paid to the renovation of the air conditioning system in the Printer house, an office building in Zwolle, Netherlands. [Dutch] Begin jaren negentig zijn veel kantoorpanden gebouwd waarvan de klimaatinstallatie tegenwoordig niet meer voldoet. De ventilatiecapaciteit is ontoereikend en koeling is mondjesmaat aanwezig, of slechts als topkoeling. Het comfort en de luchtkwaliteit zijn dan ook onder de maat. Er zijn verschillende mogelijkheden om dit te verbeteren. Plaatsing van een nieuwe luchtbehandelingskast met warmteterugwinning is daar een van. In dit artikel wordt ...

2007-05-15